WorldWideScience

Sample records for disorder quantitative measurement

  1. Quantitative electroencephalographic measures in homicidal men with antisocial personality disorder.

    Science.gov (United States)

    Lindberg, Nina; Tani, Pekka; Virkkunen, Matti; Porkka-Heiskanen, Tarja; Appelberg, Björn; Naukkarinen, Hannu; Salmi, Tapani

    2005-07-15

    Many symptoms of antisocial personality disorder have been proposed to be related to decreased daytime vigilance. To explore this hypothesis, quantitative analyses were conducted of the electroencephalographic (EEG) activity of drug-free and detoxified homicidal male offenders with antisocial personality disorder as the primary diagnosis. Subjects comprised 16 men recruited from a forensic psychiatric examination in a special ward of a university psychiatric hospital. Fifteen healthy age- and gender-matched controls with no criminal record or history of physical violence consisted of hospital staff and students. An overall reduction of alpha power was observed in the waking EEG of offenders. A bilateral increase in occipital delta and theta power was also found in these individuals. This study provides further support to the growing evidence of brain dysfunction in severe aggressive behavior. Homicidal offenders with antisocial personality disorder seem to have difficulties in maintaining normal daytime arousal. Decreased vigilance, together with social and psychological variables, may explain their aberrant behavior in everyday life. New studies are, however, needed to specify the vigilance problems of this patient group.

  2. Speech graphs provide a quantitative measure of thought disorder in psychosis.

    Science.gov (United States)

    Mota, Natalia B; Vasconcelos, Nivaldo A P; Lemos, Nathalia; Pieretti, Ana C; Kinouchi, Osame; Cecchi, Guillermo A; Copelli, Mauro; Ribeiro, Sidarta

    2012-01-01

    Psychosis has various causes, including mania and schizophrenia. Since the differential diagnosis of psychosis is exclusively based on subjective assessments of oral interviews with patients, an objective quantification of the speech disturbances that characterize mania and schizophrenia is in order. In principle, such quantification could be achieved by the analysis of speech graphs. A graph represents a network with nodes connected by edges; in speech graphs, nodes correspond to words and edges correspond to semantic and grammatical relationships. To quantify speech differences related to psychosis, interviews with schizophrenics, manics and normal subjects were recorded and represented as graphs. Manics scored significantly higher than schizophrenics in ten graph measures. Psychopathological symptoms such as logorrhea, poor speech, and flight of thoughts were grasped by the analysis even when verbosity differences were discounted. Binary classifiers based on speech graph measures sorted schizophrenics from manics with up to 93.8% of sensitivity and 93.7% of specificity. In contrast, sorting based on the scores of two standard psychiatric scales (BPRS and PANSS) reached only 62.5% of sensitivity and specificity. The results demonstrate that alterations of the thought process manifested in the speech of psychotic patients can be objectively measured using graph-theoretical tools, developed to capture specific features of the normal and dysfunctional flow of thought, such as divergence and recurrence. The quantitative analysis of speech graphs is not redundant with standard psychometric scales but rather complementary, as it yields a very accurate sorting of schizophrenics and manics. Overall, the results point to automated psychiatric diagnosis based not on what is said, but on how it is said.

  3. Speech graphs provide a quantitative measure of thought disorder in psychosis.

    Directory of Open Access Journals (Sweden)

    Natalia B Mota

    Full Text Available BACKGROUND: Psychosis has various causes, including mania and schizophrenia. Since the differential diagnosis of psychosis is exclusively based on subjective assessments of oral interviews with patients, an objective quantification of the speech disturbances that characterize mania and schizophrenia is in order. In principle, such quantification could be achieved by the analysis of speech graphs. A graph represents a network with nodes connected by edges; in speech graphs, nodes correspond to words and edges correspond to semantic and grammatical relationships. METHODOLOGY/PRINCIPAL FINDINGS: To quantify speech differences related to psychosis, interviews with schizophrenics, manics and normal subjects were recorded and represented as graphs. Manics scored significantly higher than schizophrenics in ten graph measures. Psychopathological symptoms such as logorrhea, poor speech, and flight of thoughts were grasped by the analysis even when verbosity differences were discounted. Binary classifiers based on speech graph measures sorted schizophrenics from manics with up to 93.8% of sensitivity and 93.7% of specificity. In contrast, sorting based on the scores of two standard psychiatric scales (BPRS and PANSS reached only 62.5% of sensitivity and specificity. CONCLUSIONS/SIGNIFICANCE: The results demonstrate that alterations of the thought process manifested in the speech of psychotic patients can be objectively measured using graph-theoretical tools, developed to capture specific features of the normal and dysfunctional flow of thought, such as divergence and recurrence. The quantitative analysis of speech graphs is not redundant with standard psychometric scales but rather complementary, as it yields a very accurate sorting of schizophrenics and manics. Overall, the results point to automated psychiatric diagnosis based not on what is said, but on how it is said.

  4. Comparison of a parent-rated DSM-IV measure of attention-deficit/hyperactivity disorder and quantitative EEG parameters in an outpatient sample of children.

    Science.gov (United States)

    Coolidge, Frederick L; Starkey, Michael T; Cahill, Brian S

    2007-08-01

    Attention-deficit/hyperactivity disorder (ADHD) was investigated using the parent-as-respondent, 200-item, Coolidge Personality and Neuropsychology Inventory (CPNI) and a quantitative electroencephalograph (QEEG). Parents of 183 children (mean age = 12.2 years) brought to an outpatient private clinic for behavioral and/or emotional problems completed the CPNI including the 18-item DSM-IV-based ADHD scale and their children were also evaluated by QEEG. The correlation between the CPNI ADHD scale T score and the categorical QEEG parameter (based on the beta-theta power ratio) for the identification of ADHD was r = -0.15. Using a dichotomous ADHD CPNI measure (positive/negative) and the QEEG beta-theta power ratio resulted in an r value of -0.09. The sensitivity of the QEEG ADHD parameter and the CPNI ADHD scale was 50% and the specificity was 36%. The results stand in contrast to those of who found 90% sensitivity and 94% specificity between behavioral measures of ADHD and the QEEG scanning procedure. The lack of correspondence between the two measures is discussed.

  5. In-vivo quantitative measurement

    International Nuclear Information System (INIS)

    Ito, Takashi

    1992-01-01

    So far by positron CT, the quantitative analyses of oxygen consumption rate, blood flow distribution, glucose metabolic rate and so on have been carried out. The largest merit of using the positron CT is the observation and verification of mankind have become easy. Recently, accompanying the rapid development of the mapping tracers for central nervous receptors, the observation of many central nervous receptors by the positron CT has become feasible, and must expectation has been placed on the elucidation of brain functions. The conditions required for in vitro processes cannot be realized in strict sense in vivo. The quantitative measurement of in vivo tracer method is carried out by measuring the accumulation and movement of a tracer after its administration. The movement model of the mapping tracer for central nervous receptors is discussed. The quantitative analysis using a steady movement model, the measurement of dopamine receptors by reference method, the measurement of D 2 receptors using 11C-Racloprode by direct method, and the possibility of measuring dynamics bio-reaction are reported. (K.I.)

  6. Practical quantitative measures of ALARA

    International Nuclear Information System (INIS)

    Kathren, R.L.; Larson, H.V.

    1982-06-01

    Twenty specific quantitative measures to assist in evaluating the effectiveness of as low as reasonably achievable (ALARA) programs are described along with their applicability, practicality, advantages, disadvantages, and potential for misinterpretation or dortion. Although no single index or combination of indices is suitable for all facilities, generally, these five: (1) mean individual dose equivalent (MIDE) to the total body from penetrating radiations; (2) statistical distribution of MIDE to the whole body from penetrating radiations; (3) cumulative penetrating whole body dose equivalent; (4) MIDE evaluated by job classification; and (5) MIDE evaluated by work location-apply to most programs. Evaluation of other programs may require other specific dose equivalent based indices, including extremity exposure data, cumulative dose equivalent to organs or to the general population, and nonpenetrating radiation dose equivalents. Certain nondose equivalent indices, such as the size of the radiation or contamination area, may also be used; an airborne activity index based on air concentration, room volume, and radiotoxicity is developed for application in some ALARA programs

  7. Quantitative Ultrasound Measurements at the Heel

    DEFF Research Database (Denmark)

    Daugschies, M.; Brixen, K.; Hermann, P.

    2015-01-01

    Calcaneal quantitative ultrasound can be used to predict osteoporotic fracture risk, but its ability to monitor therapy is unclear possibly because of its limited precision. We developed a quantitative ultrasound device (foot ultrasound scanner) that measures the speed of sound at the heel...... with the foot ultrasound scanner reduced precision errors by half (p quantitative ultrasound measurements is feasible. (E-mail: m.daugschies@rad.uni-kiel.de) (C) 2015 World Federation for Ultrasound in Medicine & Biology....

  8. Quantitative autoradiography - a method of radioactivity measurement

    International Nuclear Information System (INIS)

    Treutler, H.C.; Freyer, K.

    1988-01-01

    In the last years the autoradiography has been developed to a quantitative method of radioactivity measurement. Operating techniques of quantitative autoradiography are demonstrated using special standard objects. Influences of irradiation quality, of backscattering in sample and detector materials, and of sensitivity and fading of the detectors are considered. Furthermore, questions of quantitative evaluation of autoradiograms are dealt with, and measuring errors are discussed. Finally, some practical uses of quantitative autoradiography are demonstrated by means of the estimation of activity distribution in radioactive foil samples. (author)

  9. Quantitative measures with WREX usage.

    Science.gov (United States)

    Shank, Tracy M; Wee, Jinyong; Ty, Jennifer; Rahman, Tariq

    2017-07-01

    This paper presents the results of two surveys conducted with users of a functional upper extremity orthosis called the Wilmington Robotic EXoskeleton (WREX). The WREX is a passive anti-gravity arm orthosis that allows people with neuromuscular disabilities to move their arms in three dimensions. An online user survey with 55 patients was conducted to determine the benefits of the WREX. The survey asked 10 questions related to upper extremity function with and without the WREX as well as subjective impressions of the device. A second survey used a phone interview based on the Canadian Occupational Performance Measure (COPM). Parents rated their child's performance and satisfaction while partaking in important activities both with and without the exoskeleton device. Scores were assessed for change between the two conditions. Twenty-five families responded to this survey. Twenty-four out of 25 subjects reported greater levels of performance and satisfaction when they were wearing the WREX. The mean change in performance score was 3.61 points, and the mean change in satisfaction score was 4.44 points. Results show a statistically significant improvement in arm function for everyday tasks with the WREX.

  10. Quantitative genetic analysis of anxiety trait in bipolar disorder.

    Science.gov (United States)

    Contreras, J; Hare, E; Chavarría, G; Raventós, H

    2018-01-01

    Bipolar disorder type I (BPI) affects approximately 1% of the world population. Although genetic influences on bipolar disorder are well established, identification of genes that predispose to the illness has been difficult. Most genetic studies are based on categorical diagnosis. One strategy to overcome this obstacle is the use of quantitative endophenotypes, as has been done for other medical disorders. We studied 619 individuals, 568 participants from 61 extended families and 51 unrelated healthy controls. The sample was 55% female and had a mean age of 43.25 (SD 13.90; range 18-78). Heritability and genetic correlation of the trait scale from the Anxiety State and Trait Inventory (STAI) was computed by using the general linear model (SOLAR package software). we observed that anxiety trait meets the following criteria for an endophenotype of bipolar disorder type I (BPI): 1) association with BPI (individuals with BPI showed the highest trait score (F = 15.20 [5,24], p = 0.009), 2) state-independence confirmed after conducting a test-retest in 321 subjects, 3) co-segregation within families 4) heritability of 0.70 (SE: 0.060), p = 2.33 × 10 -14 and 5) genetic correlation with BPI was 0.20, (SE = 0.17, p = 3.12 × 10 -5 ). Confounding factors such as comorbid disorders and pharmacological treatment could affect the clinical relationship between BPI and anxiety trait. Further research is needed to evaluate if anxiety traits are specially related to BPI in comparison with other traits such as anger, attention or response inhibition deficit, pathological impulsivity or low self-directedness. Anxiety trait is a heritable phenotype that follows a normal distribution when measured not only in subjects with BPI but also in unrelated healthy controls. It could be used as an endophenotype in BPI for the identification of genomic regions with susceptibility genes for this disorder. Published by Elsevier B.V.

  11. Electric Field Quantitative Measurement System and Method

    Science.gov (United States)

    Generazio, Edward R. (Inventor)

    2016-01-01

    A method and system are provided for making a quantitative measurement of an electric field. A plurality of antennas separated from one another by known distances are arrayed in a region that extends in at least one dimension. A voltage difference between at least one selected pair of antennas is measured. Each voltage difference is divided by the known distance associated with the selected pair of antennas corresponding thereto to generate a resulting quantity. The plurality of resulting quantities defined over the region quantitatively describe an electric field therein.

  12. Quantitative results near the band edges of disordered systems

    International Nuclear Information System (INIS)

    Economou, E.N.; Soukoulis, C.M.; Cohen, M.H.; Zdetsis, A.D.

    1985-01-01

    By combining the coherent-potential approximation, the potential-well analogy, and theories for the near tail in the density of states, we obtain, for the first time, explicitly quantitative results for the various quantities of interest near the band edges of disordered systems. These results exhibit a certain universality and can be expressed in terms of simple analytic functions, provided that disorder is not larger than about (1/5) of the bandwidth

  13. Radioimmunoassay to quantitatively measure cell surface immunoglobulins

    International Nuclear Information System (INIS)

    Krishman, E.C.; Jewell, W.R.

    1975-01-01

    A radioimmunoassay techniques developed to quantitatively measure the presence of immunoglobulins on the surface of cells, is described. The amount of immunoglobulins found on different tumor cells varied from 200 to 1140 ng/10 6 cells. Determination of immunoglobulins on the peripheral lymphocytes obtained from different cancer patients varied between 340 to 1040 ng/10 6 cells. Cultured tumor cells, on the other hand, were found to contain negligible quantities of human IgG [pt

  14. Quantitative tomographic measurements of opaque multiphase flows

    Energy Technology Data Exchange (ETDEWEB)

    GEORGE,DARIN L.; TORCZYNSKI,JOHN R.; SHOLLENBERGER,KIM ANN; O' HERN,TIMOTHY J.; CECCIO,STEVEN L.

    2000-03-01

    An electrical-impedance tomography (EIT) system has been developed for quantitative measurements of radial phase distribution profiles in two-phase and three-phase vertical column flows. The EIT system is described along with the computer algorithm used for reconstructing phase volume fraction profiles. EIT measurements were validated by comparison with a gamma-densitometry tomography (GDT) system. The EIT system was used to accurately measure average solid volume fractions up to 0.05 in solid-liquid flows, and radial gas volume fraction profiles in gas-liquid flows with gas volume fractions up to 0.15. In both flows, average phase volume fractions and radial volume fraction profiles from GDT and EIT were in good agreement. A minor modification to the formula used to relate conductivity data to phase volume fractions was found to improve agreement between the methods. GDT and EIT were then applied together to simultaneously measure the solid, liquid, and gas radial distributions within several vertical three-phase flows. For average solid volume fractions up to 0.30, the gas distribution for each gas flow rate was approximately independent of the amount of solids in the column. Measurements made with this EIT system demonstrate that EIT may be used successfully for noninvasive, quantitative measurements of dispersed multiphase flows.

  15. Quantitative Linkage for Autism Spectrum Disorders Symptoms in Attention-Deficit/Hyperactivity Disorder : Significant Locus on Chromosome 7q11

    NARCIS (Netherlands)

    Nijmeijer, Judith; Arias-Vasquez, Alejandro; Rommelse, Nanda N. J.; Altink, Marieke E.; Buschgens, Cathelijne J. M.; Fliers, Ellen A.; Franke, Barbara; Minderaa, Rudolf; Sergeant, Joseph A.; Buitelaar, Jan K.; Hoekstra, Pieter J.; Hartman, Catharina A.

    We studied 261 ADHD probands and 354 of their siblings to assess quantitative trait loci associated with autism spectrum disorder symptoms (as measured by the Children's Social Behavior Questionnaire (CSBQ)) using a genome-wide linkage approach, followed by locus-wide association analysis. A

  16. Quantitative Linkage for Autism Spectrum Disorders Symptoms in Attention-Deficit/Hyperactivity Disorder: Significant Locus on Chromosome 7q11

    Science.gov (United States)

    Nijmeijer, Judith S.; Arias-Vásquez, Alejandro; Rommelse, Nanda N.; Altink, Marieke E.; Buschgens, Cathelijne J.; Fliers, Ellen A.; Franke, Barbara; Minderaa, Ruud B.; Sergeant, Joseph A.; Buitelaar, Jan K.; Hoekstra, Pieter J.; Hartman, Catharina A.

    2014-01-01

    We studied 261 ADHD probands and 354 of their siblings to assess quantitative trait loci associated with autism spectrum disorder symptoms (as measured by the Children's Social Behavior Questionnaire (CSBQ) using a genome-wide linkage approach, followed by locus-wide association analysis. A genome-wide significant locus for the CSBQ subscale…

  17. A measurement of disorder in binary sequences

    Science.gov (United States)

    Gong, Longyan; Wang, Haihong; Cheng, Weiwen; Zhao, Shengmei

    2015-03-01

    We propose a complex quantity, AL, to characterize the degree of disorder of L-length binary symbolic sequences. As examples, we respectively apply it to typical random and deterministic sequences. One kind of random sequences is generated from a periodic binary sequence and the other is generated from the logistic map. The deterministic sequences are the Fibonacci and Thue-Morse sequences. In these analyzed sequences, we find that the modulus of AL, denoted by |AL | , is a (statistically) equivalent quantity to the Boltzmann entropy, the metric entropy, the conditional block entropy and/or other quantities, so it is a useful quantitative measure of disorder. It can be as a fruitful index to discern which sequence is more disordered. Moreover, there is one and only one value of |AL | for the overall disorder characteristics. It needs extremely low computational costs. It can be easily experimentally realized. From all these mentioned, we believe that the proposed measure of disorder is a valuable complement to existing ones in symbolic sequences.

  18. Quantitative measurement of the cerebral blood flow

    International Nuclear Information System (INIS)

    Houdart, R.; Mamo, H.; Meric, P.; Seylaz, J.

    1976-01-01

    The value of the cerebral blood flow measurement (CBF) is outlined, its limits are defined and some future prospects discussed. The xenon 133 brain clearance study is at present the most accurate quantitative method to evaluate the CBF in different regions of the brain simultaneously. The method and the progress it has led to in the physiological, physiopathological and therapeutic fields are described. The major disadvantage of the method is shown to be the need to puncture the internal carotid for each measurement. Prospects are discussed concerning methods derived from the same general principle but using a simpler, non-traumatic way to introduce the radio-tracer, either by breathing into the lungs or intraveinously [fr

  19. Initial Description of a Quantitative, Cross-Species (Chimpanzee-Human) Social Responsiveness Measure

    Science.gov (United States)

    Marrus, Natasha; Faughn, Carley; Shuman, Jeremy; Petersen, Steve E.; Constantino, John N.; Povinelli, Daniel J.; Pruett, John R., Jr.

    2011-01-01

    Objective: Comparative studies of social responsiveness, an ability that is impaired in autism spectrum disorders, can inform our understanding of both autism and the cognitive architecture of social behavior. Because there is no existing quantitative measure of social responsiveness in chimpanzees, we generated a quantitative, cross-species…

  20. QUANTITATIVE EEG COMPARATIVE ANALYSIS BETWEEN AUTISM SPECTRUM DISORDER (ASD AND ATTENTION DEFICIT HYPERACTIVITY DISORDER (ADHD

    Directory of Open Access Journals (Sweden)

    Plamen D. Dimitrov

    2017-01-01

    Full Text Available Background: Autism is a mental developmental disorder, manifested in the early childhood. Attention deficit hyperactivity disorder is another psychiatric condition of the neurodevelopmental type. Both disorders affect information processing in the nervous system, altering the mechanisms which control how neurons and their synapses are connected and organized. Purpose: To examine if quantitative EEG assessment is sensitive and simple enough to differentiate autism from attention deficit hyperactivity disorder and neurologically typical children. Material and methods: Quantitative EEG is a type of electrophysiological assessment that uses computerized mathematical analysis to convert the raw waveform data into different frequency ranges. Each frequency range is averaged across a sample of data and quantified into mean amplitude (voltage in microvolts mV. We performed quantitative EEG analysis and compared 4 cohorts of children (aged from 3 to 7 years: with autism (high [n=27] and low [n=52] functioning, with attention deficit hyperactivity disorder [n=34], and with typical behavior [n75]. Results: Our preliminary results show that there are significant qEEG differences between the groups of patients and the control cohort. The changes affect the potential levels of delta-, theta-, alpha-, and beta- frequency spectrums. Conclusion: The present study shows some significant quantitative EEG findings in autistic patients. This is a step forward in our efforts, aimed at defining specific neurophysiologic changes, in order to develop and refine strategies for early diagnosis of autism spectrum disorders, differentiation from other development conditions in childhood, detection of specific biomarkers and early initiation of treatment.

  1. Quantitative Measurements using Ultrasound Vector Flow Imaging

    DEFF Research Database (Denmark)

    Jensen, Jørgen Arendt

    2016-01-01

    scanner for pulsating flow mimicking the femoral artery from a CompuFlow 1000 pump (Shelley Medical). Data were used in four estimators based on directional transverse oscillation for velocity, flow angle, volume flow, and turbulence estimation and their respective precisions. An adaptive lag scheme gave...... the ability to estimate a large velocity range, or alternatively measure at two sites to find e.g. stenosis degree in a vessel. The mean angle at the vessel center was estimated to 90.9◦±8.2◦ indicating a laminar flow from a turbulence index being close to zero (0.1 ±0.1). Volume flow was 1.29 ±0.26 mL/stroke...... (true: 1.15 mL/stroke, bias: 12.2%). Measurements down to 160 mm were obtained with a relative standard deviation and bias of less than 10% for the lateral component for stationary, parabolic flow. The method can, thus, find quantitative velocities, angles, and volume flows at sites currently...

  2. Quantitative biological measurement in Transmission Electron Tomography

    International Nuclear Information System (INIS)

    Mantell, Judith M; Verkade, Paul; Arkill, Kenton P

    2012-01-01

    It has been known for some time that biological sections shrink in the transmission electron microscope from exposure to the electron beam. This phenomenon is especially important in Electron Tomography (ET). The effect on shrinkage of parameters such as embedding medium or sample type is less well understood. In addition anisotropic area shrinkage has largely been ignored. The intention of this study is to explore the shrinkage on a number of samples ranging in thickness from 200 nm to 500 nm. A protocol was developed to determine the shrinkage in area and thickness using the gold fiducials used in electron tomography. In brief: Using low dose philosophy on the section, a focus area was used prior to a separate virgin study area for a series of known exposures on a tilted sample. The shrinkage was determined by measurements on the gold beads from both sides of the section as determined by a confirmatory tomogram. It was found that the shrinkage in area (approximately to 90-95% of the original) and the thickness (approximately 65% of the original at most) agreed with pervious authors, but that a lmost all the shrinkage was in the first minute and that although the direction of the in-plane shrinkage (in x and y) was sometimes uneven the end result was consistent. It was observed, in general, that thinner samples showed more percentage shrinkage than thicker ones. In conclusion, if direct quantitative measurements are required then the protocol described should be used for all areas studied.

  3. Quantitative biological measurement in Transmission Electron Tomography

    Science.gov (United States)

    Mantell, Judith M.; Verkade, Paul; Arkill, Kenton P.

    2012-07-01

    It has been known for some time that biological sections shrink in the transmission electron microscope from exposure to the electron beam. This phenomenon is especially important in Electron Tomography (ET). The effect on shrinkage of parameters such as embedding medium or sample type is less well understood. In addition anisotropic area shrinkage has largely been ignored. The intention of this study is to explore the shrinkage on a number of samples ranging in thickness from 200 nm to 500 nm. A protocol was developed to determine the shrinkage in area and thickness using the gold fiducials used in electron tomography. In brief: Using low dose philosophy on the section, a focus area was used prior to a separate virgin study area for a series of known exposures on a tilted sample. The shrinkage was determined by measurements on the gold beads from both sides of the section as determined by a confirmatory tomogram. It was found that the shrinkage in area (approximately to 90-95% of the original) and the thickness (approximately 65% of the original at most) agreed with pervious authors, but that a lmost all the shrinkage was in the first minute and that although the direction of the in-plane shrinkage (in x and y) was sometimes uneven the end result was consistent. It was observed, in general, that thinner samples showed more percentage shrinkage than thicker ones. In conclusion, if direct quantitative measurements are required then the protocol described should be used for all areas studied.

  4. Quantitative Measurement of Oxygen in Microgravity Combustion

    Science.gov (United States)

    Silver, Joel A.

    1997-01-01

    A low-gravity environment, in space or in ground-based facilities such as drop towers, provides a unique setting for studying combustion mechanisms. Understanding the physical phenomena controlling the ignition and spread of flames in microgravity has importance for space safety as well as for better characterization of dynamical and chemical combustion processes which are normally masked by buoyancy and other gravity-related effects. Due to restrictions associated with performing measurements in reduced gravity, diagnostic methods which have been applied to microgravity combustion studies have generally been limited to capture of flame emissions on film or video, laser Schlieren imaging and (intrusive) temperature measurements using thermocouples. Given the development of detailed theoretical models, more sophisticated diagnostic methods are needed to provide the kind of quantitative data necessary to characterize the properties of microgravity combustion processes as well as provide accurate feedback to improve the predictive capabilities of the models. When the demands of space flight are considered, the need for improved diagnostic systems which are rugged, compact, reliable, and operate at low power becomes apparent. The objective of this research is twofold. First, we want to develop a better understanding of the relative roles of diffusion and reaction of oxygen in microgravity combustion. As the primary oxidizer species, oxygen plays a major role in controlling the observed properties of flames, including flame front speed (in solid or liquid flames), extinguishment characteristics, flame size and flame temperature. The second objective is to develop better diagnostics based on diode laser absorption which can be of real value in both microgravity combustion research and as a sensor on-board Spacelab as either an air quality monitor or as part of a fire detection system. In our prior microgravity work, an eight line-of-sight fiber optic system measured

  5. Connecting qualitative observation and quantitative measurement for enhancing quantitative literacy in plant anatomy course

    Science.gov (United States)

    Nuraeni, E.; Rahmat, A.

    2018-05-01

    Forming of cognitive schemes of plant anatomy concepts is performed by processing of qualitative and quantitative data obtained from microscopic observations. To enhancing student’s quantitative literacy, strategy of plant anatomy course was modified by adding the task to analyze quantitative data produced by quantitative measurement of plant anatomy guided by material course. Participant in this study was 24 biology students and 35 biology education students. Quantitative Literacy test, complex thinking in plant anatomy test and questioner used to evaluate the course. Quantitative literacy capability data was collected by quantitative literacy test with the rubric from the Association of American Colleges and Universities, Complex thinking in plant anatomy by test according to Marzano and questioner. Quantitative literacy data are categorized according to modified Rhodes and Finley categories. The results showed that quantitative literacy of biology education students is better than biology students.

  6. The Relationship between Quantitative and Qualitative Measures of Writing Skills.

    Science.gov (United States)

    Howerton, Mary Lou P.; And Others

    The relationships of quantitative measures of writing skills to overall writing quality as measured by the E.T.S. Composition Evaluation Scale (CES) were examined. Quantitative measures included indices of language productivity, vocabulary diversity, spelling, and syntactic maturity. Power of specific indices to account for variation in overall…

  7. Quantitative Method of Measuring Metastatic Activity

    Science.gov (United States)

    Morrison, Dennis R. (Inventor)

    1999-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated uroldnase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  8. Smile line assessment comparing quantitative measurement and visual estimation

    NARCIS (Netherlands)

    Geld, P. Van der; Oosterveld, P.; Schols, J.; Kuijpers-Jagtman, A.M.

    2011-01-01

    INTRODUCTION: Esthetic analysis of dynamic functions such as spontaneous smiling is feasible by using digital videography and computer measurement for lip line height and tooth display. Because quantitative measurements are time-consuming, digital videography and semiquantitative (visual) estimation

  9. A quantitative measure of myelination development in infants, using MR images

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, Dennis P. [Robert Wood Johnson Medical School, New Brunswick, NJ (United States); Dunn, Stanley M.; Boddie-Willis, Akiza S. [The State University of New Jersey, Rutgers, New Brunswick, NJ (United States); DeMarco, J. Kevin [Laurie Imaging Center, New Brunswick, NJ (United States); Lewis, Michael [Robert Wood Johnson Medical School, New Brunswick, NJ (United States); Robert Wood Johnson Medical School, University of Medicine and Dentistry of New Jersey, Institute for the Study of Child Development, New Brunswick (United States)

    2004-09-01

    The objective of this study was to measure myelination of frontal lobe changes in infants and young children. Twenty-four cases of infants and children (age range 12-121 months) were evaluated by a quantitative assessment of T2-weighted MR image features. Reliable quantitative changes between white and gray matter correlated with developmental age in a group of children with no neurological findings. Myelination appears to be an increasing exponential function with the greatest rate of change occurring over the first 3 years of life. The quantitative changes observed were in accordance with previous qualitative judgments of myelination development. Children with periventricular leukomalacia (PVL) showed delays in achieving levels of myelination when compared to normal children and adjusted for chronological age. The quantitative measure of myelination development may prove to be useful in assessing the stages of development and helpful in the quantitative descriptions of white matter disorders such as PVL. (orig.)

  10. A quantitative measure of myelination development in infants, using MR images

    International Nuclear Information System (INIS)

    Carmody, Dennis P.; Dunn, Stanley M.; Boddie-Willis, Akiza S.; DeMarco, J. Kevin; Lewis, Michael

    2004-01-01

    The objective of this study was to measure myelination of frontal lobe changes in infants and young children. Twenty-four cases of infants and children (age range 12-121 months) were evaluated by a quantitative assessment of T2-weighted MR image features. Reliable quantitative changes between white and gray matter correlated with developmental age in a group of children with no neurological findings. Myelination appears to be an increasing exponential function with the greatest rate of change occurring over the first 3 years of life. The quantitative changes observed were in accordance with previous qualitative judgments of myelination development. Children with periventricular leukomalacia (PVL) showed delays in achieving levels of myelination when compared to normal children and adjusted for chronological age. The quantitative measure of myelination development may prove to be useful in assessing the stages of development and helpful in the quantitative descriptions of white matter disorders such as PVL. (orig.)

  11. Quantitative Measures of Mineral Supply Risk

    Science.gov (United States)

    Long, K. R.

    2009-12-01

    Almost all metals and many non-metallic minerals are traded internationally. An advantage of global mineral markets is that minerals can be obtained from the globally lowest-cost source. For example, one rare-earth element (REE) mine in China, Bayan Obo, is able to supply most of world demand for rare earth elements at a cost significantly less than its main competitors. Concentration of global supplies at a single mine raises significant political risks, illustrated by China’s recent decision to prohibit the export of some REEs and severely limit the export of others. The expected loss of REE supplies will have a significant impact on the cost and production of important national defense technologies and on alternative energy programs. Hybrid vehicles and wind-turbine generators, for example, require REEs for magnets and batteries. Compact fluorescent light bulbs use REE-based phosphors. These recent events raise the general issue of how to measure the degree of supply risk for internationally sourced minerals. Two factors, concentration of supply and political risk, must first be addressed. Concentration of supply can be measured with standard economic tools for measuring industry concentration, using countries rather than firms as the unit of analysis. There are many measures of political risk available. That of the OECD is a measure of a country’s commitment to rule-of-law and enforcement of contracts, as well as political stability. Combining these measures provides a comparative view of mineral supply risk across commodities and identifies several minerals other than REEs that could suddenly become less available. Combined with an assessment of the impact of a reduction in supply, decision makers can use these measures to prioritize risk reduction efforts.

  12. Quantitative clinical uptake measurements using conjugate counting

    International Nuclear Information System (INIS)

    Lathrop, K.A.; Bartlett, R.D.; Chen, C.T.; Chou, J.S.; Faulhaber, P.F.; Harper, P.V.; Stark, V.J.

    1986-01-01

    While the use of conjugate counting for determination of organ uptake in human subjects has been extensively described, in the present study the determination of the organ uptake of ortho-iodohippurate presented several opportunities for validation of the in vivo counting data. Ortho-iodohippurate is distributed in the extracellular space, is largely extracted on each pass through the kidneys, and is not significantly deiodinated in vivo. Thus, the kidney uptake rate should be proportional to the blood level, the appearance rate of activity in the bladder is equal to the disappearance rate from the kidneys, and direct measurement of activity in the urine after voiding provides an internal standard for imaging measurements of bladder activity. Since the activity levels in the kidneys, bladder, and remainder of the body changed fairly rapidly, especially in the first 20 to 30 minutes following injection, posterior images of the trunk including kidneys and bladder were obtained continuously using a gamma camera fitted with a diverging collimator for 30 minutes and then at intervals for several hours. Simultaneous conjugate counting determinations were made using a whole body scanning system previously described at these meetings. Imaging data corrected for decay and adjacent background were fitted by least squares methods to curves representing a sum of exponentials, and the curves were normalized to the conjugate uptake measurements. The uptake curves of the kidneys and bladder matched well with the direct measurements of the urinary excretion. Data were collected in 16 normal subjects, and the estimated absorbed dose was calculated for the kidneys, the bladder and the remainder of the body for seven radioisotopes of iodine. 4 references, 6 figures, 2 tables

  13. Semi-automated quantitative Drosophila wings measurements.

    Science.gov (United States)

    Loh, Sheng Yang Michael; Ogawa, Yoshitaka; Kawana, Sara; Tamura, Koichiro; Lee, Hwee Kuan

    2017-06-28

    Drosophila melanogaster is an important organism used in many fields of biological research such as genetics and developmental biology. Drosophila wings have been widely used to study the genetics of development, morphometrics and evolution. Therefore there is much interest in quantifying wing structures of Drosophila. Advancement in technology has increased the ease in which images of Drosophila can be acquired. However such studies have been limited by the slow and tedious process of acquiring phenotypic data. We have developed a system that automatically detects and measures key points and vein segments on a Drosophila wing. Key points are detected by performing image transformations and template matching on Drosophila wing images while vein segments are detected using an Active Contour algorithm. The accuracy of our key point detection was compared against key point annotations of users. We also performed key point detection using different training data sets of Drosophila wing images. We compared our software with an existing automated image analysis system for Drosophila wings and showed that our system performs better than the state of the art. Vein segments were manually measured and compared against the measurements obtained from our system. Our system was able to detect specific key points and vein segments from Drosophila wing images with high accuracy.

  14. Quantitative measurements of autobiographical memory content.

    Directory of Open Access Journals (Sweden)

    Robert S Gardner

    Full Text Available Autobiographical memory (AM, subjective recollection of past experiences, is fundamental in everyday life. Nevertheless, characterization of the spontaneous occurrence of AM, as well as of the number and types of recollected details, remains limited. The CRAM (Cue-Recalled Autobiographical Memory test (http://cramtest.info adapts and combines the cue-word method with an assessment that collects counts of details recalled from different life periods. The SPAM (Spontaneous Probability of Autobiographical Memories protocol samples introspection during everyday activity, recording memory duration and frequency. These measures provide detailed, naturalistic accounts of AM content and frequency, quantifying essential dimensions of recollection. AM content (∼20 details/recollection decreased with the age of the episode, but less drastically than the probability of reporting remote compared to recent memories. AM retrieval was frequent (∼20/hour, each memory lasting ∼30 seconds. Testable hypotheses of the specific content retrieved in a fixed time from given life periods are presented.

  15. Quantitative NMR measurements on core samples

    International Nuclear Information System (INIS)

    Olsen, Dan

    1997-01-01

    Within the frame of an EFP-95 project NMR methods for porosity determination in 2D, and for fluid saturation determination in 1D and 2D have been developed. The three methods have been developed and tested on cleaned core samples of chalk from the Danish North Sea. The main restriction for the use of the methods is the inherently short T2 relaxation constants of rock samples. Referring to measurements conducted at 200 MHz, the 2D porosity determination method is applicable to sample material with T2 relaxation constants down to 5 ms. The 1D fluid saturation determination method is applicable to sample material with T2 relaxation constants down to 3 ms, while the 2D fluid saturation determination method is applicable to material with T2 relaxation constants down to 8 ms. In the case of the 2D methods these constraints as a minimum enables work on the majority of chalk samples of Maastrichtian age. The 1D fluid saturation determination method in addition is applicable to at least some chalk samples of Danian and pre-Maastrichtian age. The spatial resolution of the 2D porosity determination method, the 1D fluid saturation methods, and the 2D fluid saturation method is respectively 0.8 mm, 0.8 mm and 2 mm. Reproducibility of pixel values is for all three methods 2%- points. (au)

  16. Combining SPECT and Quantitative EEG Analysis for the Automated Differential Diagnosis of Disorders with Amnestic Symptoms

    Directory of Open Access Journals (Sweden)

    Yvonne Höller

    2017-09-01

    Full Text Available Single photon emission computed tomography (SPECT and Electroencephalography (EEG have become established tools in routine diagnostics of dementia. We aimed to increase the diagnostic power by combining quantitative markers from SPECT and EEG for differential diagnosis of disorders with amnestic symptoms. We hypothesize that the combination of SPECT with measures of interaction (connectivity in the EEG yields higher diagnostic accuracy than the single modalities. We examined 39 patients with Alzheimer's dementia (AD, 69 patients with depressive cognitive impairment (DCI, 71 patients with amnestic mild cognitive impairment (aMCI, and 41 patients with amnestic subjective cognitive complaints (aSCC. We calculated 14 measures of interaction from a standard clinical EEG-recording and derived graph-theoretic network measures. From regional brain perfusion measured by 99mTc-hexamethyl-propylene-aminoxime (HMPAO-SPECT in 46 regions, we calculated relative cerebral perfusion in these patients. Patient groups were classified pairwise with a linear support vector machine. Classification was conducted separately for each biomarker, and then again for each EEG- biomarker combined with SPECT. Combination of SPECT with EEG-biomarkers outperformed single use of SPECT or EEG when classifying aSCC vs. AD (90%, aMCI vs. AD (70%, and AD vs. DCI (100%, while a selection of EEG measures performed best when classifying aSCC vs. aMCI (82% and aMCI vs. DCI (90%. Only the contrast between aSCC and DCI did not result in above-chance classification accuracy (60%. In general, accuracies were higher when measures of interaction (i.e., connectivity measures were applied directly than when graph-theoretical measures were derived. We suggest that quantitative analysis of EEG and machine-learning techniques can support differentiating AD, aMCI, aSCC, and DCC, especially when being combined with imaging methods such as SPECT. Quantitative analysis of EEG connectivity could become

  17. Measurement Invariance: A Foundational Principle for Quantitative Theory Building

    Science.gov (United States)

    Nimon, Kim; Reio, Thomas G., Jr.

    2011-01-01

    This article describes why measurement invariance is a critical issue to quantitative theory building within the field of human resource development. Readers will learn what measurement invariance is and how to test for its presence using techniques that are accessible to applied researchers. Using data from a LibQUAL+[TM] study of user…

  18. Smile line assessment comparing quantitative measurement and visual estimation.

    Science.gov (United States)

    Van der Geld, Pieter; Oosterveld, Paul; Schols, Jan; Kuijpers-Jagtman, Anne Marie

    2011-02-01

    Esthetic analysis of dynamic functions such as spontaneous smiling is feasible by using digital videography and computer measurement for lip line height and tooth display. Because quantitative measurements are time-consuming, digital videography and semiquantitative (visual) estimation according to a standard categorization are more practical for regular diagnostics. Our objective in this study was to compare 2 semiquantitative methods with quantitative measurements for reliability and agreement. The faces of 122 male participants were individually registered by using digital videography. Spontaneous and posed smiles were captured. On the records, maxillary lip line heights and tooth display were digitally measured on each tooth and also visually estimated according to 3-grade and 4-grade scales. Two raters were involved. An error analysis was performed. Reliability was established with kappa statistics. Interexaminer and intraexaminer reliability values were high, with median kappa values from 0.79 to 0.88. Agreement of the 3-grade scale estimation with quantitative measurement showed higher median kappa values (0.76) than the 4-grade scale estimation (0.66). Differentiating high and gummy smile lines (4-grade scale) resulted in greater inaccuracies. The estimation of a high, average, or low smile line for each tooth showed high reliability close to quantitative measurements. Smile line analysis can be performed reliably with a 3-grade scale (visual) semiquantitative estimation. For a more comprehensive diagnosis, additional measuring is proposed, especially in patients with disproportional gingival display. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  19. Quantitative measurements of shear displacement using atomic force microscopy

    International Nuclear Information System (INIS)

    Wang, Wenbo; Wu, Weida; Sun, Ying; Zhao, Yonggang

    2016-01-01

    We report a method to quantitatively measure local shear deformation with high sensitivity using atomic force microscopy. The key point is to simultaneously detect both torsional and buckling motions of atomic force microscopy (AFM) cantilevers induced by the lateral piezoelectric response of the sample. This requires the quantitative calibration of torsional and buckling response of AFM. This method is validated by measuring the angular dependence of the in-plane piezoelectric response of a piece of piezoelectric α-quartz. The accurate determination of the amplitude and orientation of the in-plane piezoelectric response, without rotation, would greatly enhance the efficiency of lateral piezoelectric force microscopy.

  20. A new lowry's technique for quantitative measurement of protein

    International Nuclear Information System (INIS)

    Chen Ge; Zou Wenquan; Sun Jianzhong; Zhang Yanggang; Shu Bohua; Liu Shenpei; Gong Xiaoliang

    1990-01-01

    According to the queneching principle in beta ray measurement, liquid scintillation counters are used for quantitative measurement of protein. The results show linear relationship between the colored protein samples with different concentrations and the counting rate of LSC. It is proved that LSC method is less erroneous and has larger measurement range than the traditional photoelectric colorimetry, and the analysis is easy to be automatized

  1. Quantitative Evaluation of the Use of Actigraphy for Neurological and Psychiatric Disorders

    Directory of Open Access Journals (Sweden)

    Weidong Pan

    2014-01-01

    Full Text Available Quantitative and objective evaluation of disease severity and/or drug effect is necessary in clinical practice. Wearable accelerometers such as an actigraph enable long-term recording of a patient’s movement during activities and they can be used for quantitative assessment of symptoms due to various diseases. We reviewed some applications of actigraphy with analytical methods that are sufficiently sensitive and reliable to determine the severity of diseases and disorders such as motor and nonmotor disorders like Parkinson’s disease, sleep disorders, depression, behavioral and psychological symptoms of dementia (BPSD for vascular dementia (VD, seasonal affective disorder (SAD, and stroke, as well as the effects of drugs used to treat them. We believe it is possible to develop analytical methods to assess more neurological or psychopathic disorders using actigraphy records.

  2. Quantitative 99mTc diphosphonate uptake measurements

    International Nuclear Information System (INIS)

    Smith, M.L.

    1987-01-01

    There are several different techniques currently in use for quantifying diphosphonate uptake by the skeleton. These can be considered in two main categories: local bone or whole-body uptake measurements. The choice of technique depends on the clinical problem being investigated and also on available equipment an expertise. The wide variety of approaches to diphosphonate quantitation ensures that these measurements can be obtained in almost any nuclear medicine department. This chapter discusses the general factors which may influence diphosphonate uptake measurements and outlines the techniques most relevant to current clinical practice

  3. Calibration of quantitative neutron radiography method for moisture measurement

    International Nuclear Information System (INIS)

    Nemec, T.; Jeraj, R.

    1999-01-01

    Quantitative measurements of moisture and hydrogenous matter in building materials by neutron radiography (NR) are regularly performed at TRIGA Mark II research of 'Jozef Stefan' Institute in Ljubljana. Calibration of quantitative method is performed using standard brick samples with known moisture content and also with a secondary standard, plexiglas step wedge. In general, the contribution of scattered neutrons to the neutron image is not determined explicitly what introduces an error to the measured signal. Influence of scattered neutrons is significant in regions with high gradients of moisture concentrations, where the build up of scattered neutrons causes distortion of the moisture concentration profile. In this paper detailed analysis of validity of our calibration method for different geometrical parameters is presented. The error in the measured hydrogen concentration is evaluated by an experiment and compared with results obtained by Monte Carlo calculation with computer code MCNP 4B. Optimal conditions are determined for quantitative moisture measurements in order to minimize the error due to scattered neutrons. The method is tested on concrete samples with high moisture content.(author)

  4. Quantitative computed tomography for measuring bone mineral content

    International Nuclear Information System (INIS)

    Felsenberg, D.; Kalender, W.A.; Banzer, D.; Schmilinsky, G.; Heyse, M.; Fischer, E.; Schneider, U.; Siemens A.G., Erlangen; Krankenhaus Zehlendorf, Berlin

    1988-01-01

    Quantitative computed tomography (QCT) for measuring bone mineral content of lumbar vertebrae is increasingly used internationally. The effect of using conventional CT (single energy CT, SE-CT) and dual energy CT (DE-CT) on reproducibility has been examined. We defined a standard measurement protocol, which automatically evaluates a calibration phantom. This should ensure an in vivo reproducibility of 1 to 2%. Reference data, which has been obtained with this protocol from 113 normal subjects, using SE-CT ad DE-CT, are presented. (orig.) [de

  5. Quantitative nanoscale surface voltage measurement on organic semiconductor blends

    International Nuclear Information System (INIS)

    Cuenat, Alexandre; Muñiz-Piniella, Andrés; Muñoz-Rojo, Miguel; Murphy, Craig E; Tsoi, Wing C

    2012-01-01

    We report on the validation of a method based on Kelvin probe force microscopy (KPFM) able to measure the different phases and the relative work function of polymer blend heterojunctions at the nanoscale. The method does not necessitate complex ultra-high vacuum setup. The quantitative information that can be extracted from the topography and the Kelvin probe measurements is critically analysed. Surface voltage difference can be observed at the nanoscale on poly(3-hexyl-thiophene):[6,6]-phenyl-C61-butyric acid methyl ester (P3HT:PCBM) blends and dependence on the annealing condition and the regio-regularity of P3HT is observed. (paper)

  6. Computer controlled scanning systems for quantitative track measurements

    International Nuclear Information System (INIS)

    Gold, R.; Roberts, J.H.; Preston, C.C.; Ruddy, F.H.

    1982-01-01

    The status of three computer cntrolled systems for quantitative track measurements is described. Two systems, an automated optical track scanner (AOTS) and an automated scanning electron microscope (ASEM) are used for scanning solid state track recorders (SSTR). The third system, the emulsion scanning processor (ESP), is an interactive system used to measure the length of proton tracks in nuclear research emulsions (NRE). Recent advances achieved with these systems are presented, with emphasis placed upon the current limitation of these systems for reactor neutron dosimetry

  7. A quantitative method for measuring the quality of history matches

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, T.S. [Kerr-McGee Corp., Oklahoma City, OK (United States); Knapp, R.M. [Univ. of Oklahoma, Norman, OK (United States)

    1997-08-01

    History matching can be an efficient tool for reservoir characterization. A {open_quotes}good{close_quotes} history matching job can generate reliable reservoir parameters. However, reservoir engineers are often frustrated when they try to select a {open_quotes}better{close_quotes} match from a series of history matching runs. Without a quantitative measurement, it is always difficult to tell the difference between a {open_quotes}good{close_quotes} and a {open_quotes}better{close_quotes} matches. For this reason, we need a quantitative method for testing the quality of matches. This paper presents a method for such a purpose. The method uses three statistical indices to (1) test shape conformity, (2) examine bias errors, and (3) measure magnitude of deviation. The shape conformity test insures that the shape of a simulated curve matches that of a historical curve. Examining bias errors assures that model reservoir parameters have been calibrated to that of a real reservoir. Measuring the magnitude of deviation assures that the difference between the model and the real reservoir parameters is minimized. The method was first tested on a hypothetical model and then applied to published field studies. The results showed that the method can efficiently measure the quality of matches. It also showed that the method can serve as a diagnostic tool for calibrating reservoir parameters during history matching.

  8. Weighing evidence: quantitative measures of the importance of bitemark evidence.

    Science.gov (United States)

    Kittelson, J M; Kieser, J A; Buckingham, D M; Herbison, G P

    2002-12-01

    Quantitative measures of the importance of evidence such as the "likelihood ratio" have become increasingly popular in the courtroom. These measures have been used by expert witnesses formally to describe their certainty about a piece of evidence. These measures are commonly interpreted as the amount by which the evidence should revise the opinion of guilt, and thereby summarize the importance of a particular piece of evidence. Unlike DNA evidence, quantitative measures have not been widely used by forensic dentists to describe their certainty when testifying about bitemark evidence. There is, however, no inherent reason why they should not be used to evaluate bitemarks. The purpose of this paper is to describe the likelihood ratio as it might be applied to bitemark evidence. We use a simple bitemark example to define the likelihood ratio, its application, and interpretation. In particular we describe how the jury interprets the likelihood ratio from a Bayesian perspective when evaluating the impact of the evidence on the odds that the accused is guilty. We describe how the dentist would calculate the likelihood ratio based on frequentist interpretations. We also illustrate some of the limitations of the likelihood ratio, and show how those limitations apply to bitemark evidence. We conclude that the quality of bitemark evidence cannot be adequately summarized by the likelihood ratio, and argue that its application in this setting may be more misleading than helpful.

  9. Quantitative assessment of motor speech abnormalities in idiopathic rapid eye movement sleep behaviour disorder.

    Science.gov (United States)

    Rusz, Jan; Hlavnička, Jan; Tykalová, Tereza; Bušková, Jitka; Ulmanová, Olga; Růžička, Evžen; Šonka, Karel

    2016-03-01

    Patients with idiopathic rapid eye movement sleep behaviour disorder (RBD) are at substantial risk for developing Parkinson's disease (PD) or related neurodegenerative disorders. Speech is an important indicator of motor function and movement coordination, and therefore may be an extremely sensitive early marker of changes due to prodromal neurodegeneration. Speech data were acquired from 16 RBD subjects and 16 age- and sex-matched healthy control subjects. Objective acoustic assessment of 15 speech dimensions representing various phonatory, articulatory, and prosodic deviations was performed. Statistical models were applied to characterise speech disorders in RBD and to estimate sensitivity and specificity in differentiating between RBD and control subjects. Some form of speech impairment was revealed in 88% of RBD subjects. Articulatory deficits were the most prominent findings in RBD. In comparison to controls, the RBD group showed significant alterations in irregular alternating motion rates (p = 0.009) and articulatory decay (p = 0.01). The combination of four distinctive speech dimensions, including aperiodicity, irregular alternating motion rates, articulatory decay, and dysfluency, led to 96% sensitivity and 79% specificity in discriminating between RBD and control subjects. Speech impairment was significantly more pronounced in RBD subjects with the motor score of the Unified Parkinson's Disease Rating Scale greater than 4 points when compared to other RBD individuals. Simple quantitative speech motor measures may be suitable for the reliable detection of prodromal neurodegeneration in subjects with RBD, and therefore may provide important outcomes for future therapy trials. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Radioisotope studies for quantitative measurement of manganese absorption

    International Nuclear Information System (INIS)

    Helbig, U.

    1981-01-01

    Purpose of the present study was to quantitatively determine the manganese absorption in growing rats by means of radioisotopes. First of all the following factors had to be investigated, which are significant for this determination: Measurability of stable and radioactive Mn in rat tissues; labelling of stable Mn and distribution of stable and radioactive Mn in the organism; verification of the isotope dilution method and of the comparative balance method with regard to its applicability for the determination of the true Mn absorption. We useed male and female Sprague-Dawley rats. The most important results are summarized in the following: in some separate tissues measurement of stable Mn was accompanied by difficulties. The measurement of radioactive Mn however, could be performed without any problems. 10 d after i.m. injection of 54 Mn only 17% of the administered Mn was still detectable in the organism. However, there was no uniform tissue labelling found. Therefore it is possible to an only restricted extent to draw quantitative conclusions on the content of stable Mn. A high percentage of stable and radioactive Mn was found above all in the liver. The isotope dilution method permits by feces analysis to differentiate between unabsorbed Mn coming from the food and endogenic Mn coming from the organism itself. The effective Mn absorption was also determined by means of the comparative balance method. By means of the isotope dilution method we determined the quantitative Mn-absorption with staged Mn administration and the contribution of absorption and excretion to the homeostatic regulation mechanisms of Mn. We found that absorption and excretion help the organism to keep an almost constant Mn concentration even with a differing Mn supply. (orig./MG) [de

  11. Quantitative measurement of intervertebral disc signal using MRI

    International Nuclear Information System (INIS)

    Niemelaeinen, R.; Videman, T.; Dhillon, S.S.; Battie, M.C.

    2008-01-01

    Aim: To investigate the spinal cord as an alternative intra-body reference to cerebrospinal fluid (CSF) in evaluating thoracic disc signal intensity. Materials and methods: T2-weighted magnetic resonance imaging (MRI) images of T6-T12 were obtained using 1.5 T machines for a population-based sample of 523 men aged 35-70 years. Quantitative data on the signal intensities were acquired using an image analysis program (SpEx (copy right) ). A random sample of 30 subjects and intraclass correlation coeffcients (ICC) were used to examine the repeatability of the spinal cord measurements. The validity of using the spinal cord as a reference was examined by correlating cord and CSF samples. Finally, thoracic disc signal was validated by correlating it with age without adjustment and adjusting for either cord or CSF. Pearson's r was used for correlational analyses. Results: The repeatability of the spinal cord signal measurements was extremely high (≥0.99). The correlations between the signals of spinal cord and CSF by level were all above 0.9. The spinal cord-adjusted disc signal and age correlated similarly with CSF-adjusted disc signal and age (r = -0.30 to -0.40 versus r = -0.26 to -0.36). Conclusion: Adjacent spinal cord is a good alternative reference to the current reference standard, CSF, for quantitative measurements of disc signal intensity. Clearly fewer levels were excluded when using spinal cord as compared to CSF due to missing reference samples

  12. Quantitative measurement of maritime sediment movement using radioactive tracers

    International Nuclear Information System (INIS)

    Makovski, E.; Grissener, G.

    1967-01-01

    The quantitative method described in the paper involves burying appropriate detectors over a given area of the sea bottom, the detectors being connected to recording equipment which is itself buried in the sediment or situated on the shore. Detectors arranged in this way are covered by a certain layer of radioactive sediment whose activity is proportional to its mass. Before the labelled sediments are removed, their initial activity is measured, and then, as the covering is removed, measurements are made of the gradual decrease in activity corresponding to loss of the surface layer of the bottom deposit area under investigation, expressed in g/cm 2 . The tracers used in the investigations discussed were natural ones such as sea with 31 Si and artificial ones such as activated fragments of sodium glass (with a 6.5% admixture of Fe 2 O 3 ) with 24 Na . The proportional dependence of activity on mass has been confirmed for both tracers; this is an essential point for a tracer intended for quantitative measurements. This proportionality is very well maintained if a sample of highly active sediment is introduced into a large mass of inactive sediments (10 -2 - 10 -3 ). The concluding section describes the advantages of this method as a possible way of using radioisotopes with a short half-life and a low total activity of the order of a few millicuries. (author)

  13. Advanced quantitative measurement methodology in physics education research

    Science.gov (United States)

    Wang, Jing

    parts. The first part involves the comparison between item response theory (IRT) and classical test theory (CTT). The two theories both provide test item statistics for educational inferences and decisions. The two theories are both applied to Force Concept Inventory data obtained from students enrolled in The Ohio State University. Effort was made to examine the similarity and difference between the two theories, and the possible explanation to the difference. The study suggests that item response theory is more sensitive to the context and conceptual features of the test items than classical test theory. The IRT parameters provide a better measure than CTT parameters for the educational audience to investigate item features. The second part of the dissertation is on the measure of association for binary data. In quantitative assessment, binary data is often encountered because of its simplicity. The current popular measures of association fail under some extremely unbalanced conditions. However, the occurrence of these conditions is not rare in educational data. Two popular association measures, the Pearson's correlation and the tetrachoric correlation are examined. A new method, model based association is introduced, and an educational testing constraint is discussed. The existing popular methods are compared with the model based association measure with and without the constraint. Connections between the value of association and the context and conceptual features of questions are discussed in detail. Results show that all the methods have their advantages and disadvantages. Special attention to the test and data conditions is necessary. The last part of the dissertation is focused on exploratory factor analysis (EFA). The theoretical advantages of EFA are discussed. Typical misunderstanding and misusage of EFA are explored. The EFA is performed on Lawson's Classroom Test of Scientific Reasoning (LCTSR), a widely used assessment on scientific reasoning skills. The

  14. CBCL Pediatric Bipolar Disorder Profile and ADHD: Comorbidity and Quantitative Trait Loci Analysis

    Science.gov (United States)

    McGough, James J.; Loo, Sandra K.; McCracken, James T.; Dang, Jeffery; Clark, Shaunna; Nelson, Stanley F.; Smalley, Susan L.

    2008-01-01

    The pediatric bipolar disorder profile of the Child Behavior checklist is used to differentiate patterns of comorbidity and to search for quantitative trait loci in multiple affected ADHD sibling pairs. The CBCL-PBD profiling identified 8 percent of individuals with severe psychopathology and increased rates of oppositional defiant, conduct and…

  15. A quantitative measure of handwriting dysfluency for assessing tardive dyskinesia.

    Science.gov (United States)

    Caligiuri, Michael P; Teulings, Hans-Leo; Dean, Charles E; Lohr, James B

    2015-04-01

    Tardive dyskinesia (TD) is a movement disorder commonly associated with chronic exposure to antidopaminergic medications, which may be in some cases disfiguring and socially disabling. The consensus from a growing body of research on the incidence and prevalence of TD in the modern era of antipsychotics indicates that this disorder has not disappeared continues to challenge the effective management of psychotic symptoms in patients with schizophrenia. A fundamental component in an effective strategy for managing TD is its reliable and accurate assessment. In the present study, we examined the clinical utility of a brief handwriting dysfluency measure for quantifying TD. Digitized samples of handwritten circles and loops were obtained from 62 psychosis patients with or without TD and from 50 healthy subjects. Two measures of dysfluent pen movements were extracted from each vertical pen stroke, including normalized jerk and the number of acceleration peaks. Tardive dyskinesia patients exhibited significantly higher dysfluency scores than non-TD patients and controls. Severity of handwriting movement dysfluency was correlated with Abnormal Involuntary Movement Scale severity ratings for some tasks. The procedure yielded high degrees of test-retest reliability. These results suggest that measures of handwriting movement dysfluency may be particularly useful for objectively evaluating the efficacy of pharmacotherapeutic strategies for treating TD.

  16. An improved fast neutron radiography quantitative measurement method

    International Nuclear Information System (INIS)

    Matsubayashi, Masahito; Hibiki, Takashi; Mishima, Kaichiro; Yoshii, Koji; Okamoto, Koji

    2004-01-01

    The validity of a fast neutron radiography quantification method, the Σ-scaling method, which was originally proposed for thermal neutron radiography was examined with Monte Carlo calculations and experiments conducted at the YAYOI fast neutron source reactor. Water and copper were selected as comparative samples for a thermal neutron radiography case and a dense object, respectively. Although different characteristics on effective macroscopic cross-sections were implied by the simulation, the Σ-scaled experimental results with the fission neutron spectrum cross-sections were well fitted to the measurements for both the water and copper samples. This indicates that the Σ-scaling method could be successfully adopted for quantitative measurements in fast neutron radiography

  17. Quantitative Thermochemical Measurements in High-Pressure Gaseous Combustion

    Science.gov (United States)

    Kojima, Jun J.; Fischer, David G.

    2012-01-01

    We present our strategic experiment and thermochemical analyses on combustion flow using a subframe burst gating (SBG) Raman spectroscopy. This unconventional laser diagnostic technique has promising ability to enhance accuracy of the quantitative scalar measurements in a point-wise single-shot fashion. In the presentation, we briefly describe an experimental methodology that generates transferable calibration standard for the routine implementation of the diagnostics in hydrocarbon flames. The diagnostic technology was applied to simultaneous measurements of temperature and chemical species in a swirl-stabilized turbulent flame with gaseous methane fuel at elevated pressure (17 atm). Statistical analyses of the space-/time-resolved thermochemical data provide insights into the nature of the mixing process and it impact on the subsequent combustion process in the model combustor.

  18. Single-case synthesis tools II: Comparing quantitative outcome measures.

    Science.gov (United States)

    Zimmerman, Kathleen N; Pustejovsky, James E; Ledford, Jennifer R; Barton, Erin E; Severini, Katherine E; Lloyd, Blair P

    2018-03-07

    Varying methods for evaluating the outcomes of single case research designs (SCD) are currently used in reviews and meta-analyses of interventions. Quantitative effect size measures are often presented alongside visual analysis conclusions. Six measures across two classes-overlap measures (percentage non-overlapping data, improvement rate difference, and Tau) and parametric within-case effect sizes (standardized mean difference and log response ratio [increasing and decreasing])-were compared to determine if choice of synthesis method within and across classes impacts conclusions regarding effectiveness. The effectiveness of sensory-based interventions (SBI), a commonly used class of treatments for young children, was evaluated. Separately from evaluations of rigor and quality, authors evaluated behavior change between baseline and SBI conditions. SBI were unlikely to result in positive behavior change across all measures except IRD. However, subgroup analyses resulted in variable conclusions, indicating that the choice of measures for SCD meta-analyses can impact conclusions. Suggestions for using the log response ratio in SCD meta-analyses and considerations for understanding variability in SCD meta-analysis conclusions are discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  19. Quantitative measurement of intervertebral disc signal using MRI

    Energy Technology Data Exchange (ETDEWEB)

    Niemelaeinen, R. [Faculty of Rehabilitation Medicine, University of Alberta, Edmonton (Canada)], E-mail: riikka.niemelainen@ualberta.ca; Videman, T. [Faculty of Rehabilitation Medicine, University of Alberta, Edmonton (Canada); Dhillon, S.S. [Department of Radiology and Diagnostic Imaging, University of Alberta, Edmonton (Canada); Battie, M.C. [Faculty of Rehabilitation Medicine, University of Alberta, Edmonton (Canada)

    2008-03-15

    Aim: To investigate the spinal cord as an alternative intra-body reference to cerebrospinal fluid (CSF) in evaluating thoracic disc signal intensity. Materials and methods: T2-weighted magnetic resonance imaging (MRI) images of T6-T12 were obtained using 1.5 T machines for a population-based sample of 523 men aged 35-70 years. Quantitative data on the signal intensities were acquired using an image analysis program (SpEx (copy right) ). A random sample of 30 subjects and intraclass correlation coeffcients (ICC) were used to examine the repeatability of the spinal cord measurements. The validity of using the spinal cord as a reference was examined by correlating cord and CSF samples. Finally, thoracic disc signal was validated by correlating it with age without adjustment and adjusting for either cord or CSF. Pearson's r was used for correlational analyses. Results: The repeatability of the spinal cord signal measurements was extremely high ({>=}0.99). The correlations between the signals of spinal cord and CSF by level were all above 0.9. The spinal cord-adjusted disc signal and age correlated similarly with CSF-adjusted disc signal and age (r = -0.30 to -0.40 versus r = -0.26 to -0.36). Conclusion: Adjacent spinal cord is a good alternative reference to the current reference standard, CSF, for quantitative measurements of disc signal intensity. Clearly fewer levels were excluded when using spinal cord as compared to CSF due to missing reference samples.

  20. Quantitative Measures of Swallowing Deficits in Patients With Parkinson's Disease.

    Science.gov (United States)

    Ellerston, Julia K; Heller, Amanda C; Houtz, Daniel R; Kendall, Katherine A

    2016-05-01

    Dysphagia and associated aspiration pneumonia are commonly reported sequelae of Parkinson's disease (PD). Previous studies of swallowing in patients with PD have described prolonged pharyngeal transit time, delayed onset of pharyngeal transit, cricopharyngeal (CP) achalasia, reduced pharyngeal constriction, and slowed hyolaryngeal elevation. These studies were completed using inconsistent evaluation methodology, reliance on qualitative analysis, and a lack of a large control group, resulting in concerns regarding diagnostic precision. The purpose of this study was to investigate swallowing function in patients with PD using a norm-referenced, quantitative approach. This retrospective study includes 34 patients with a diagnosis of PD referred to a multidisciplinary voice and swallowing clinic. Modified barium swallow studies were performed using quantitative measures of pharyngeal transit time, hyoid displacement, CP sphincter opening, area of the pharynx at maximal constriction, and timing of laryngeal vestibule closure relative to bolus arrival at the CP sphincter. Reduced pharyngeal constriction was found in 30.4%, and a delay in airway closure relative to arrival of the bolus at the CP sphincter was the most common abnormality, present in 62% of patients. Previously reported findings of prolonged pharyngeal transit, poor hyoid elevation, and CP achalasia were not identified as prominent features. © The Author(s) 2015.

  1. Quantitative measures of healthy aging and biological age

    Science.gov (United States)

    Kim, Sangkyu; Jazwinski, S. Michal

    2015-01-01

    Numerous genetic and non-genetic factors contribute to aging. To facilitate the study of these factors, various descriptors of biological aging, including ‘successful aging’ and ‘frailty’, have been put forth as integrative functional measures of aging. A separate but related quantitative approach is the ‘frailty index’, which has been operationalized and frequently used. Various frailty indices have been constructed. Although based on different numbers and types of health variables, frailty indices possess several common properties that make them useful across different studies. We have been using a frailty index termed FI34 based on 34 health variables. Like other frailty indices, FI34 increases non-linearly with advancing age and is a better indicator of biological aging than chronological age. FI34 has a substantial genetic basis. Using FI34, we found elevated levels of resting metabolic rate linked to declining health in nonagenarians. Using FI34 as a quantitative phenotype, we have also found a genomic region on chromosome 12 that is associated with healthy aging and longevity. PMID:26005669

  2. A passive quantitative measurement of airway resistance using depth data.

    Science.gov (United States)

    Ostadabbas, Sarah; Bulach, Christoph; Ku, David N; Anderson, Larry J; Ghovanloo, Maysam

    2014-01-01

    The Respiratory Syncytial Virus (RSV) is the most common cause of serious lower respiratory tract infections in infants and young children. RSV often causes increased airway resistance, clinically detected as wheezing by chest auscultation. In this disease, expiratory flows are significantly reduced due to the high resistance in patient's airway passages. A quantitative method for measuring resistance can have a great benefit to diagnosis and management of children with RSV infections as well as with other lung diseases. Airway resistance is defined as the lung pressure divided by the airflow. In this paper, we propose a method to quantify resistance through a simple, non-contact measurement of chest volume that can act as a surrogate measure of the lung pressure and volumetric airflow. We used depth data collected by a Microsoft Kinect camera for the measurement of the lung volume over time. In our experimentation, breathing through a number of plastic straws induced different airway resistances. For a standard spirometry test, our volume/flow estimation using Kinect showed strong correlation with the flow data collected by a commercially-available spirometer (five subjects, each performing 20 breathing trials, correlation coefficient = 0.88, with 95% confidence interval). As the number of straws decreased, emulating a higher airway obstruction, our algorithm was sufficient to distinguish between several levels of airway resistance.

  3. Developing quantitative tools for measuring aspects of prisonization

    DEFF Research Database (Denmark)

    Kjær Minke, Linda

    2013-01-01

    The article describes and discusses the preparation and completion of a quantitative study among prison officers and prisoners.......The article describes and discusses the preparation and completion of a quantitative study among prison officers and prisoners....

  4. A novel semi-quantitative method for measuring tissue bleeding.

    Science.gov (United States)

    Vukcevic, G; Volarevic, V; Raicevic, S; Tanaskovic, I; Milicic, B; Vulovic, T; Arsenijevic, S

    2014-03-01

    In this study, we describe a new semi-quantitative method for measuring the extent of bleeding in pathohistological tissue samples. To test our novel method, we recruited 120 female patients in their first trimester of pregnancy and divided them into three groups of 40. Group I was the control group, in which no dilation was applied. Group II was an experimental group, in which dilation was performed using classical mechanical dilators. Group III was also an experimental group, in which dilation was performed using a hydraulic dilator. Tissue samples were taken from the patients' cervical canals using a Novak's probe via energetic single-step curettage prior to any dilation in Group I and after dilation in Groups II and III. After the tissue samples were prepared, light microscopy was used to obtain microphotographs at 100x magnification. The surfaces affected by bleeding were measured in the microphotographs using the Autodesk AutoCAD 2009 program and its "polylines" function. The lines were used to mark the area around the entire sample (marked A) and to create "polyline" areas around each bleeding area on the sample (marked B). The percentage of the total area affected by bleeding was calculated using the formula: N = Bt x 100 / At where N is the percentage (%) of the tissue sample surface affected by bleeding, At (A total) is the sum of the surfaces of all of the tissue samples and Bt (B total) is the sum of all the surfaces affected by bleeding in all of the tissue samples. This novel semi-quantitative method utilizes the Autodesk AutoCAD 2009 program, which is simple to use and widely available, thereby offering a new, objective and precise approach to estimate the extent of bleeding in tissue samples.

  5. Quantitative computed tomography in measurement of vertebral trabecular bone mass

    International Nuclear Information System (INIS)

    Nilsson, M.; Johnell, O.; Jonsson, K.; Redlund-Johnell, I.

    1988-01-01

    Measurement of bone mineral concentration (BMC) can be done by several modalities. Quantitative computed tomography (QCT) can be used for measurements at different sites and with different types of bone (trabecular-cortical). This study presents a modified method reducing the influence of fat. Determination of BMC was made from measurements with single-energy computed tomography (CT) of the mean Hounsfield number in the trabecular part of the L1 vertebra. The method takes into account the age-dependent composition of the trabecular part of the vertebra. As the amount of intravertebral fat increases with age, the effective atomic number for these parts decreases. This results in a non-linear calibration curve for single-energy CT. Comparison of BMC values using the non-linear calibration curve or the traditional linear calibration with those obtained with a pixel-by-pixel based electron density calculation method (theoretically better) showed results clearly in favor of the non-linear method. The material consisted of 327 patients aged 6 to 91 years, of whom 197 were considered normal. The normal data show a sharp decrease in trabecular bone after the age of 50 in women. In men a slower decrease was found. The vertebrae were larger in men than in women. (orig.)

  6. Quantitative EEG neurofeedback for the treatment of pediatric attention-deficit/hyperactivity disorder, autism spectrum disorders, learning disorders, and epilepsy.

    Science.gov (United States)

    Hurt, Elizabeth; Arnold, L Eugene; Lofthouse, Nicholas

    2014-07-01

    Neurofeedback (NF) using surface electroencephalographic signals has been used to treat various child psychiatric disorders by providing patients with video/audio information about their brain's electrical activity in real-time. Research data are reviewed and clinical recommendations are made regarding NF treatment of youth with attention deficit/hyperactivity disorder, autism, learning disorders, and epilepsy. Most NF studies are limited by methodological issues, such as failure to use or test the validity of a full-blind or sham NF. The safety of NF treatment has not been thoroughly investigated in youth or adults, although clinical experience suggests reasonable safety. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Sooting turbulent jet flame: characterization and quantitative soot measurements

    Science.gov (United States)

    Köhler, M.; Geigle, K. P.; Meier, W.; Crosland, B. M.; Thomson, K. A.; Smallwood, G. J.

    2011-08-01

    Computational fluid dynamics (CFD) modelers require high-quality experimental data sets for validation of their numerical tools. Preferred features for numerical simulations of a sooting, turbulent test case flame are simplicity (no pilot flame), well-defined boundary conditions, and sufficient soot production. This paper proposes a non-premixed C2H4/air turbulent jet flame to fill this role and presents an extensive database for soot model validation. The sooting turbulent jet flame has a total visible flame length of approximately 400 mm and a fuel-jet Reynolds number of 10,000. The flame has a measured lift-off height of 26 mm which acts as a sensitive marker for CFD model validation, while this novel compiled experimental database of soot properties, temperature and velocity maps are useful for the validation of kinetic soot models and numerical flame simulations. Due to the relatively simple burner design which produces a flame with sufficient soot concentration while meeting modelers' needs with respect to boundary conditions and flame specifications as well as the present lack of a sooting "standard flame", this flame is suggested as a new reference turbulent sooting flame. The flame characterization presented here involved a variety of optical diagnostics including quantitative 2D laser-induced incandescence (2D-LII), shifted-vibrational coherent anti-Stokes Raman spectroscopy (SV-CARS), and particle image velocimetry (PIV). Producing an accurate and comprehensive characterization of a transient sooting flame was challenging and required optimization of these diagnostics. In this respect, we present the first simultaneous, instantaneous PIV, and LII measurements in a heavily sooting flame environment. Simultaneous soot and flow field measurements can provide new insights into the interaction between a turbulent vortex and flame chemistry, especially since soot structures in turbulent flames are known to be small and often treated in a statistical manner.

  8. Quantitative analysis of impact measurements using dynamic load cells

    Directory of Open Access Journals (Sweden)

    Brent J. Maranzano

    2016-03-01

    Full Text Available A mathematical model is used to estimate material properties from a short duration transient impact force measured by dropping spheres onto rectangular coupons fixed to a dynamic load cell. The contact stress between the dynamic load cell surface and the projectile are modeled using Hertzian contact mechanics. Due to the short impact time relative to the load cell dynamics, an additional Kelvin–Voigt element is included in the model to account for the finite response time of the piezoelectric crystal. Calculations with and without the Kelvin–Voigt element are compared to experimental data collected from combinations of polymeric spheres and polymeric and metallic surfaces. The results illustrate that the inclusion of the Kelvin–Voigt element qualitatively captures the post impact resonance and non-linear behavior of the load cell signal and quantitatively improves the estimation of the Young's elastic modulus and Poisson's ratio. Mathematically, the additional KV element couples one additional differential equation to the Hertzian spring-dashpot equation. The model can be numerically integrated in seconds using standard numerical techniques allowing for its use as a rapid technique for the estimation of material properties. Keywords: Young's modulus, Poisson's ratio, Dynamic load cell

  9. Measuring Filament Orientation: A New Quantitative, Local Approach

    Energy Technology Data Exchange (ETDEWEB)

    Green, C.-E.; Cunningham, M. R.; Jones, P. A. [School of Physics, University of New South Wales, Sydney, NSW, 2052 (Australia); Dawson, J. R. [CSIRO Astronomy and Space Science, Australia Telescope National Facility, P.O. Box 76, Epping, NSW 1710 (Australia); Novak, G. [Center for Interdisciplinary Exploration and Research in Astrophysics (CIERA) and Department of Physics and Astronomy, Northwestern University, 2145 Sheridan Road, Evanston, IL 60208 (United States); Fissel, L. M. [National Radio Astronomy Observatory (NRAO), 520 Edgemont Road, Charlottesville, VA, 22903 (United States)

    2017-09-01

    The relative orientation between filamentary structures in molecular clouds and the ambient magnetic field provides insight into filament formation and stability. To calculate the relative orientation, a measurement of filament orientation is first required. We propose a new method to calculate the orientation of the one-pixel-wide filament skeleton that is output by filament identification algorithms such as filfinder. We derive the local filament orientation from the direction of the intensity gradient in the skeleton image using the Sobel filter and a few simple post-processing steps. We call this the “Sobel-gradient method.” The resulting filament orientation map can be compared quantitatively on a local scale with the magnetic field orientation map to then find the relative orientation of the filament with respect to the magnetic field at each point along the filament. It can also be used for constructing radial profiles for filament width fitting. The proposed method facilitates automation in analyses of filament skeletons, which is imperative in this era of “big data.”.

  10. Quantitative Laughter Detection, Measurement, and Classification-A Critical Survey.

    Science.gov (United States)

    Cosentino, Sarah; Sessa, Salvatore; Takanishi, Atsuo

    2016-01-01

    The study of human nonverbal social behaviors has taken a more quantitative and computational approach in recent years due to the development of smart interfaces and virtual agents or robots able to interact socially. One of the most interesting nonverbal social behaviors, producing a characteristic vocal signal, is laughing. Laughter is produced in several different situations: in response to external physical, cognitive, or emotional stimuli; to negotiate social interactions; and also, pathologically, as a consequence of neural damage. For this reason, laughter has attracted researchers from many disciplines. A consequence of this multidisciplinarity is the absence of a holistic vision of this complex behavior: the methods of analysis and classification of laughter, as well as the terminology used, are heterogeneous; the findings sometimes contradictory and poorly documented. This survey aims at collecting and presenting objective measurement methods and results from a variety of different studies in different fields, to contribute to build a unified model and taxonomy of laughter. This could be successfully used for advances in several fields, from artificial intelligence and human-robot interaction to medicine and psychiatry.

  11. Measuring Filament Orientation: A New Quantitative, Local Approach

    Science.gov (United States)

    Green, C.-E.; Dawson, J. R.; Cunningham, M. R.; Jones, P. A.; Novak, G.; Fissel, L. M.

    2017-09-01

    The relative orientation between filamentary structures in molecular clouds and the ambient magnetic field provides insight into filament formation and stability. To calculate the relative orientation, a measurement of filament orientation is first required. We propose a new method to calculate the orientation of the one-pixel-wide filament skeleton that is output by filament identification algorithms such as filfinder. We derive the local filament orientation from the direction of the intensity gradient in the skeleton image using the Sobel filter and a few simple post-processing steps. We call this the “Sobel-gradient method.” The resulting filament orientation map can be compared quantitatively on a local scale with the magnetic field orientation map to then find the relative orientation of the filament with respect to the magnetic field at each point along the filament. It can also be used for constructing radial profiles for filament width fitting. The proposed method facilitates automation in analyses of filament skeletons, which is imperative in this era of “big data.”

  12. Measuring Filament Orientation: A New Quantitative, Local Approach

    International Nuclear Information System (INIS)

    Green, C.-E.; Cunningham, M. R.; Jones, P. A.; Dawson, J. R.; Novak, G.; Fissel, L. M.

    2017-01-01

    The relative orientation between filamentary structures in molecular clouds and the ambient magnetic field provides insight into filament formation and stability. To calculate the relative orientation, a measurement of filament orientation is first required. We propose a new method to calculate the orientation of the one-pixel-wide filament skeleton that is output by filament identification algorithms such as filfinder. We derive the local filament orientation from the direction of the intensity gradient in the skeleton image using the Sobel filter and a few simple post-processing steps. We call this the “Sobel-gradient method.” The resulting filament orientation map can be compared quantitatively on a local scale with the magnetic field orientation map to then find the relative orientation of the filament with respect to the magnetic field at each point along the filament. It can also be used for constructing radial profiles for filament width fitting. The proposed method facilitates automation in analyses of filament skeletons, which is imperative in this era of “big data.”

  13. Quantitative measure of randomness and order for complete genomes

    Science.gov (United States)

    Kong, Sing-Guan; Fan, Wen-Lang; Chen, Hong-Da; Wigger, Jan; Torda, Andrew E.; Lee, H. C.

    2009-06-01

    We propose an order index, ϕ , which gives a quantitative measure of randomness and order of complete genomic sequences. It maps genomes to a number from 0 (random and of infinite length) to 1 (fully ordered) and applies regardless of sequence length. The 786 complete genomic sequences in GenBank were found to have ϕ values in a very narrow range, ϕg=0.031-0.015+0.028 . We show this implies that genomes are halfway toward being completely random, or, at the “edge of chaos.” We further show that artificial “genomes” converted from literary classics have ϕ ’s that almost exactly coincide with ϕg , but sequences of low information content do not. We infer that ϕg represents a high information-capacity “fixed point” in sequence space, and that genomes are driven to it by the dynamics of a robust growth and evolution process. We show that a growth process characterized by random segmental duplication can robustly drive genomes to the fixed point.

  14. Quantitative heartbeat coupling measures in human-horse interaction.

    Science.gov (United States)

    Lanata, Antonio; Guidi, Andrea; Valenza, Gaetano; Baragli, Paolo; Scilingo, Enzo Pasquale

    2016-08-01

    We present a study focused on a quantitative estimation of a human-horse dynamic interaction. A set of measures based on magnitude and phase coupling between heartbeat dynamics of both humans and horses in three different conditions is reported: no interaction, visual/olfactory interaction and grooming. Specifically, Magnitude Squared Coherence (MSC), Mean Phase Coherence (MPC) and Dynamic Time Warping (DTW) have been used as estimators of the amount of coupling between human and horse through the analysis of their heart rate variability (HRV) time series in a group of eleven human subjects, and one horse. The rationale behind this study is that the interaction of two complex biological systems go towards a coupling process whose dynamical evolution is modulated by the kind and time duration of the interaction itself. We achieved a congruent and consistent statistical significant difference for all of the three indices. Moreover, a Nearest Mean Classifier was able to recognize the three classes of interaction with an accuracy greater than 70%. Although preliminary, these encouraging results allow a discrimination of three distinct phases in a real human-animal interaction opening to the characterization of the empirically proven relationship between human and horse.

  15. A Framework for Mixing Methods in Quantitative Measurement Development, Validation, and Revision: A Case Study

    Science.gov (United States)

    Luyt, Russell

    2012-01-01

    A framework for quantitative measurement development, validation, and revision that incorporates both qualitative and quantitative methods is introduced. It extends and adapts Adcock and Collier's work, and thus, facilitates understanding of quantitative measurement development, validation, and revision as an integrated and cyclical set of…

  16. Measuring mental disorders: The failed commensuration project of DSM-5.

    Science.gov (United States)

    Whooley, Owen

    2016-10-01

    Commensuration - the comparison of entities according to a common quantitative metric - is a key process in efforts to rationalize medicine. The push toward evidence-based medicine and quantitative assessment has led to the proliferation of metrics in healthcare. While social scientific attention has revealed the effects of these metrics once institutionalized - on clinical practice, on medical expertise, on outcome assessment, on valuations of medical services, and on experiences of illness - less attention has been paid to the process of developing metrics. This article examines the attempt to create severity scales during the revision to the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) as a case of failed commensuration. Using data from interviews with participants in the DSM-5 revision (n = 30), I reconstruct the problems that emerged in the DSM-5 Task Force's effort to develop viable psychometric instruments to measure severity. Framed as a part of a "paradigm shift" in psychiatry, the revision produced ad hoc, heterogeneous severity scales with divergent logics. I focus on two significant issues of metric construction in this case - diagnostic validity and clinical utility. Typically perceived as technical and conceptual challenges of design, I show how these issues were infused with, and undermined by, professional political dynamics, specifically tensions between medical researchers and clinicians. This case reveals that, despite its association with objectivity and transparency, commensuration encompasses more than identifying, operationalizing, and measuring an entity; it demands the negotiation of extra-scientific, non-empirical concerns that get written into medical metrics themselves. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. A Quantitative Measure For Evaluating Project Uncertainty Under Variation And Risk Effects

    Directory of Open Access Journals (Sweden)

    A. Chenarani

    2017-10-01

    Full Text Available The effects of uncertainty on a project and the risk event as the consequence of uncertainty are analyzed. The uncertainty index is proposed as a quantitative measure for evaluating the uncertainty of a project. This is done by employing entropy as the indicator of system disorder and lack of information. By employing this index, the uncertainty of each activity and its increase due to risk effects as well as project uncertainty changes as a function of time can be assessed. The results are implemented and analyzed for a small turbojet engine development project as the case study. The results of this study can be useful for project managers and other stakeholders for selecting the most effective risk management and uncertainty controlling method.

  18. Quantitative autistic trait measurements index background genetic risk for ASD in Hispanic families.

    Science.gov (United States)

    Page, Joshua; Constantino, John Nicholas; Zambrana, Katherine; Martin, Eden; Tunc, Ilker; Zhang, Yi; Abbacchi, Anna; Messinger, Daniel

    2016-01-01

    Recent studies have indicated that quantitative autistic traits (QATs) of parents reflect inherited liabilities that may index background genetic risk for clinical autism spectrum disorder (ASD) in their offspring. Moreover, preferential mating for QATs has been observed as a potential factor in concentrating autistic liabilities in some families across generations. Heretofore, intergenerational studies of QATs have focused almost exclusively on Caucasian populations-the present study explored these phenomena in a well-characterized Hispanic population. The present study examined QAT scores in siblings and parents of 83 Hispanic probands meeting research diagnostic criteria for ASD, and 64 non-ASD controls, using the Social Responsiveness Scale-2 (SRS-2). Ancestry of the probands was characterized by genotype, using information from 541,929 single nucleotide polymorphic markers. In families of Hispanic children with an ASD diagnosis, the pattern of quantitative trait correlations observed between ASD-affected children and their first-degree relatives (ICCs on the order of 0.20), between unaffected first-degree relatives in ASD-affected families (sibling/mother ICC = 0.36; sibling/father ICC = 0.53), and between spouses (mother/father ICC = 0.48) were in keeping with the influence of transmitted background genetic risk and strong preferential mating for variation in quantitative autistic trait burden. Results from analysis of ancestry-informative genetic markers among probands in this sample were consistent with that from other Hispanic populations. Quantitative autistic traits represent measurable indices of inherited liability to ASD in Hispanic families. The accumulation of autistic traits occurs within generations, between spouses, and across generations, among Hispanic families affected by ASD. The occurrence of preferential mating for QATs-the magnitude of which may vary across cultures-constitutes a mechanism by which background genetic liability

  19. Measurement of Spectral Functions of Ultracold Atoms in Disordered Potentials

    Science.gov (United States)

    Volchkov, Valentin V.; Pasek, Michael; Denechaud, Vincent; Mukhtar, Musawwadah; Aspect, Alain; Delande, Dominique; Josse, Vincent

    2018-02-01

    We report on the measurement of the spectral functions of noninteracting ultracold atoms in a three-dimensional disordered potential resulting from an optical speckle field. Varying the disorder strength by 2 orders of magnitude, we observe the crossover from the "quantum" perturbative regime of low disorder to the "classical" regime at higher disorder strength, and find an excellent agreement with numerical simulations. The method relies on the use of state-dependent disorder and the controlled transfer of atoms to create well-defined energy states. This opens new avenues for experimental investigations of three-dimensional Anderson localization.

  20. Likelihood and predictors of detention in patients with personality disorder compared with other mental disorders: A retrospective, quantitative study of Mental Health Act assessments.

    Science.gov (United States)

    Olajide, Kike; Tyrer, Peter; Singh, Swaran P; Burns, Tom; Rugkåsa, Jorun; Thana, Lavanya; Paul, Moli; Islam, Zoebia; Crawford, Mike J

    2016-08-01

    The UK guidelines on the treatment of personality disorder recommend avoiding compulsory treatment except in extreme situations. Little is known about how often patients with personality disorder are detained or how this compares with the treatment of other mental disorders. Our aim is to test the hypothesis that people with personality disorder are infrequently detained under the Mental Health Act (MHA) and that risk factors associated with detention are the same as those for people with other mental disorders. We used a retrospective, quantitative study of MHA assessments. Of the 2 087 assessments undertaken, 204 (9.8%) patients had a diagnosis of personality disorder; 40.7% of assessments in the personality disorder group resulted in detention, as did 69.7% of patients with other mental disorders. A higher proportion of people with personality disorder received no intervention following assessment compared with those with other mental disorders (20.6% vs. 4.7%, p mental disorders. Detention rates in patients with personality disorder are lower than those for other disorders but are still substantial. Risk factors for detention in patients with personality disorder differ from those with other mental disorders. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  1. Qualitative and quantitative EEG abnormalities in violent offenders with antisocial personality disorder.

    Science.gov (United States)

    Reyes, Ana Calzada; Amador, Alfredo Alvarez

    2009-02-01

    Resting eyes closed electroencephalogram was studied in a group of violent offenders evaluated at Psychiatric Department of the Legal Medicine Institute in Cuba (18 with antisocial personality disorder, ASPD, and 10 without psychiatric diagnosis). Characteristics of the EEG visual inspection and the use of frequency domain quantitative analysis techniques (narrow band spectral parameters) are described. Both groups were compared to Cuban normative database. High incidences of electroencephalographic abnormalities were found in both groups of violent offenders. The most frequent were: electrogenesis alterations, attenuated alpha rhythm and theta and delta activities increase in the frontal lobe. In the quantitative analysis theta and delta frequencies were increased and alpha activity was decreased in both groups. Differences appear for the topographical patterns present in subjects of both groups. EEG abnormalities were more severe in ASPD than in control group. Results suggest that EEG abnormalities in violent offenders should reflect aspects of brain dysfunction related to antisocial behaviour.

  2. An improved in situ measurement of offset phase shift towards quantitative damping-measurement with AFM

    International Nuclear Information System (INIS)

    Minary-Jolandan, Majid; Yu Minfeng

    2008-01-01

    An improved approach is introduced in damping measurement with atomic force microscope (AFM) for the in situ measurement of the offset phase shift needed for determining the intrinsic mechanical damping in nanoscale materials. The offset phase shift is defined and measured at a point of zero contact force according to the deflection part of the AFM force plot. It is shown that such defined offset phase shift is independent of the type of sample material, varied from hard to relatively soft materials in this study. This improved approach allows the self-calibrated and quantitative damping measurement with AFM. The ability of dynamic mechanical analysis for the measurement of damping in isolated one-dimensional nanostructures, e.g. individual multiwalled carbon nanotubes, was demonstrated

  3. Quantitative Evaluation System of Soft Neurological Signs for Children with Attention Deficit Hyperactivity Disorder

    Directory of Open Access Journals (Sweden)

    Miki Kaneko

    2016-01-01

    Full Text Available Attention deficit hyperactivity disorder (ADHD is a neurodevelopmental disorder characterized by symptoms of inattention, hyperactivity, and impulsivity. Soft neurological signs (SNS are minor neurological abnormalities in motor performance, and are used as one evaluation method for neurodevelopmental delays in children with ADHD. Our aim is to establish a quantitative evaluation system for children with ADHD. We focused on the arm movement called pronation and supination, which is one such soft neurological sign. Thirty three children with ADHD aged 7–11 years (27 males, six females and twenty five adults participants aged 21–29 years old (19 males, six females participated in our experiments. Our results suggested that the pronation and supination function in children with ADHD has a tendency to lag behind that of typically developing children by several years. From these results, our system has a possibility to objectively evaluate the neurodevelopmental delay of children with ADHD.

  4. Quantitative Evaluation System of Soft Neurological Signs for Children with Attention Deficit Hyperactivity Disorder.

    Science.gov (United States)

    Kaneko, Miki; Yamashita, Yushiro; Iramina, Keiji

    2016-01-18

    Attention deficit hyperactivity disorder (ADHD) is a neurodevelopmental disorder characterized by symptoms of inattention, hyperactivity, and impulsivity. Soft neurological signs (SNS) are minor neurological abnormalities in motor performance, and are used as one evaluation method for neurodevelopmental delays in children with ADHD. Our aim is to establish a quantitative evaluation system for children with ADHD. We focused on the arm movement called pronation and supination, which is one such soft neurological sign. Thirty three children with ADHD aged 7-11 years (27 males, six females) and twenty five adults participants aged 21-29 years old (19 males, six females) participated in our experiments. Our results suggested that the pronation and supination function in children with ADHD has a tendency to lag behind that of typically developing children by several years. From these results, our system has a possibility to objectively evaluate the neurodevelopmental delay of children with ADHD.

  5. Quantitative Measures of Chaotic Charged Particle Dynamics in the Magnetotail

    Science.gov (United States)

    Holland, D. L.; Martin, R. F., Jr.; Burris, C.

    2017-12-01

    It has long been noted that the motion of charged particles in magnetotail-like magnetic fields is chaotic, however, efforts to quantify the degree of chaos have had conflicting conclusions. In this paper we re-examine the question by focusing on quantitative measures of chaos. We first examine the percentage of orbits that enter the chaotic region of phase space and the average trapping time of those particles. We then examine the average exponential divergence rate (AEDR) of the chaotic particles between their first and last crossing of the mid-plane. We show that at resonant energies where the underlying phase space has a high degree of symmetry, only a small number of particle enter the chaotic region, but they are trapped for long periods of time and the time asymptotic value of the AEDR is very close to the average value of the AEDR. At the off-resonant energies where the phase space is highly asymmetric, the majority of the particle enter the chaotic region for fairly short periods of time and the time asymptotic value of the AEDR is much smaller than the average value. The root cause is that in the resonant case, the longest-lived orbits tend interact with the current many times and sample the entire chaotic region, whereas in the non-resonant case the longest-lived orbits only interact with the current sheet a small number of times but have very long mirrorings where the motion is nearly regular. Additionally we use an ad-hoc model where we model the current sheet as a Lorentz scattering system with each interaction with the current sheet being considered as a "collision". We find that the average kick per collision is greatest at off-resonant energies. Finally, we propose a chaos parameter as the product of the AEDR times the average chaotic particle trapping time times the percentage of orbits that are chaotic. We find that this takes on peak values at the resonant energies.

  6. Quantitative measurement of productivity loss due to thermal discomfort

    DEFF Research Database (Denmark)

    Lan, Li; Wargocki, Pawel; Lian, Zhiwei

    2011-01-01

    discomfort caused by elevated air temperature had a negative effect on performance. A quantitative relationship was established between thermal sensation votes and task performance. It can be used for economic calculations pertaining to building design and operation when occupant productivity is considered...

  7. Quantitative Ultrasound for Measuring Obstructive Severity in Children with Hydronephrosis.

    Science.gov (United States)

    Cerrolaza, Juan J; Peters, Craig A; Martin, Aaron D; Myers, Emmarie; Safdar, Nabile; Linguraru, Marius George

    2016-04-01

    We define sonographic biomarkers for hydronephrotic renal units that can predict the necessity of diuretic nuclear renography. We selected a cohort of 50 consecutive patients with hydronephrosis of varying severity in whom 2-dimensional sonography and diuretic mercaptoacetyltriglycine renography had been performed. A total of 131 morphological parameters were computed using quantitative image analysis algorithms. Machine learning techniques were then applied to identify ultrasound based safety thresholds that agreed with the t½ for washout. A best fit model was then derived for each threshold level of t½ that would be clinically relevant at 20, 30 and 40 minutes. Receiver operating characteristic curve analysis was performed. Sensitivity, specificity and area under the receiver operating characteristic curve were determined. Improvement obtained by the quantitative imaging method compared to the Society for Fetal Urology grading system and the hydronephrosis index was statistically verified. For the 3 thresholds considered and at 100% sensitivity the specificities of the quantitative imaging method were 94%, 70% and 74%, respectively. Corresponding area under the receiver operating characteristic curve values were 0.98, 0.94 and 0.94, respectively. Improvement obtained by the quantitative imaging method over the Society for Fetal Urology grade and hydronephrosis index was statistically significant (p hydronephrosis can identify thresholds of clinically significant washout times with 100% sensitivity to decrease the number of diuretic renograms in up to 62% of children. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  8. Quantitative measurement of mixtures by terahertz time–domain ...

    Indian Academy of Sciences (India)

    Administrator

    earth and space science, quality control of food and agricultural products and global environmental monitoring. In quantitative applications, terahertz technology has been widely used for studying dif- ferent kinds of mixtures, such as amino acids,. 8 ter- nary chemical mixtures,. 9 pharmaceuticals,. 10 racemic compounds. 11.

  9. Quantitative analysis of diffusion tensor imaging (DTI) using statistical parametric mapping (SPM) for brain disorders

    Science.gov (United States)

    Lee, Jae-Seung; Im, In-Chul; Kang, Su-Man; Goo, Eun-Hoe; Kwak, Byung-Joon

    2013-07-01

    This study aimed to quantitatively analyze data from diffusion tensor imaging (DTI) using statistical parametric mapping (SPM) in patients with brain disorders and to assess its potential utility for analyzing brain function. DTI was obtained by performing 3.0-T magnetic resonance imaging for patients with Alzheimer's disease (AD) and vascular dementia (VD), and the data were analyzed using Matlab-based SPM software. The two-sample t-test was used for error analysis of the location of the activated pixels. We compared regions of white matter where the fractional anisotropy (FA) values were low and the apparent diffusion coefficients (ADCs) were increased. In the AD group, the FA values were low in the right superior temporal gyrus, right inferior temporal gyrus, right sub-lobar insula, and right occipital lingual gyrus whereas the ADCs were significantly increased in the right inferior frontal gyrus and right middle frontal gyrus. In the VD group, the FA values were low in the right superior temporal gyrus, right inferior temporal gyrus, right limbic cingulate gyrus, and right sub-lobar caudate tail whereas the ADCs were significantly increased in the left lateral globus pallidus and left medial globus pallidus. In conclusion by using DTI and SPM analysis, we were able to not only determine the structural state of the regions affected by brain disorders but also quantitatively analyze and assess brain function.

  10. Quantitative Assessment of the Effects of Orientational and Positional Disorder on Glassy Dynamics

    International Nuclear Information System (INIS)

    Ramos, M.; Vieira, S.; Bermejo, F.; Dawidowski, J.; Fischer, H.; Schober, H.; Gonzalez, M.; Loong, C.; Price, D.

    1997-01-01

    The microscopic dynamics of several phases of solid ethanol are studied under the same thermodynamic conditions by inelastic neutron scattering. It is found that the vibrational density of states of the orientational glass phase, where the molecules are arranged on an ordered lattice but with disordered orientations, is very similar to that of the structural glass phase, where the molecules are disordered both in position and orientation. Low-temperature specific heat measurements on the same phases strongly support the neutron measurements. We therefore find that positional disorder, even in a stoichiometrically homogeneous system such as ethanol, is not essential for the manifestation of glasslike behavior to an extent comparable with that exhibited by the structural glass. copyright 1996 The American Physical Society

  11. Breach Risk Magnitude: A Quantitative Measure of Database Security.

    Science.gov (United States)

    Yasnoff, William A

    2016-01-01

    A quantitative methodology is described that provides objective evaluation of the potential for health record system breaches. It assumes that breach risk increases with the number of potential records that could be exposed, while it decreases when more authentication steps are required for access. The breach risk magnitude (BRM) is the maximum value for any system user of the common logarithm of the number of accessible database records divided by the number of authentication steps needed to achieve such access. For a one million record relational database, the BRM varies from 5.52 to 6 depending on authentication protocols. For an alternative data architecture designed specifically to increase security by separately storing and encrypting each patient record, the BRM ranges from 1.3 to 2.6. While the BRM only provides a limited quantitative assessment of breach risk, it may be useful to objectively evaluate the security implications of alternative database organization approaches.

  12. Quantitative method of measuring cancer cell urokinase and metastatic potential

    Science.gov (United States)

    Morrison, Dennis R. (Inventor)

    1993-01-01

    The metastatic potential of tumors can be evaluated by the quantitative detection of urokinase and DNA. The cell sample selected for examination is analyzed for the presence of high levels of urokinase and abnormal DNA using analytical flow cytometry and digital image analysis. Other factors such as membrane associated urokinase, increased DNA synthesis rates and certain receptors can be used in the method for detection of potentially invasive tumors.

  13. Quantitative EEG and neurofeedback in children and adolescents: anxiety disorders, depressive disorders, comorbid addiction and attention-deficit/hyperactivity disorder, and brain injury.

    Science.gov (United States)

    Simkin, Deborah R; Thatcher, Robert W; Lubar, Joel

    2014-07-01

    This article explores the science surrounding neurofeedback. Both surface neurofeedback (using 2-4 electrodes) and newer interventions, such as real-time z-score neurofeedback (electroencephalogram [EEG] biofeedback) and low-resolution electromagnetic tomography neurofeedback, are reviewed. The limited literature on neurofeedback research in children and adolescents is discussed regarding treatment of anxiety, mood, addiction (with comorbid attention-deficit/hyperactivity disorder), and traumatic brain injury. Future potential applications, the use of quantitative EEG for determining which patients will be responsive to medications, the role of randomized controlled studies in neurofeedback research, and sensible clinical guidelines are considered. Copyright © 2014 Elsevier Inc. All rights reserved.

  14. Quantitative measurement of cyanide species in simulated ferrocyanide Hanford waste

    International Nuclear Information System (INIS)

    Bryan, S.A.; Pool, K.H.; Matheson, J.D.

    1993-02-01

    Analytical methods for the quantification of cyanide species in Hanford simulated high-level radioactive waste were pursued in this work. Methods studied include infrared spectroscopy (solid state and solution), Raman spectroscopy, Moessbauer spectroscopy, X-ray diffraction, scanning electron microscopy-electron dispersive spectroscopy (SEM-EDS), and ion chromatography. Of these, infrared, Raman, X-ray diffraction, and ion chromatography techniques show promise in the concentration range of interest. Quantitation limits for these latter four techniques were demonstrated to be approximately 0.1 wt% (as cyanide) using simulated Hanford wastes

  15. Quantitative assessment based on kinematic measures of functional impairments during upper extremity movements: A review.

    Science.gov (United States)

    de los Reyes-Guzmán, Ana; Dimbwadyo-Terrer, Iris; Trincado-Alonso, Fernando; Monasterio-Huelin, Félix; Torricelli, Diego; Gil-Agudo, Angel

    2014-08-01

    Quantitative measures of human movement quality are important for discriminating healthy and pathological conditions and for expressing the outcomes and clinically important changes in subjects' functional state. However the most frequently used instruments for the upper extremity functional assessment are clinical scales, that previously have been standardized and validated, but have a high subjective component depending on the observer who scores the test. But they are not enough to assess motor strategies used during movements, and their use in combination with other more objective measures is necessary. The objective of the present review is to provide an overview on objective metrics found in literature with the aim of quantifying the upper extremity performance during functional tasks, regardless of the equipment or system used for registering kinematic data. A search in Medline, Google Scholar and IEEE Xplore databases was performed following a combination of a series of keywords. The full scientific papers that fulfilled the inclusion criteria were included in the review. A set of kinematic metrics was found in literature in relation to joint displacements, analysis of hand trajectories and velocity profiles. These metrics were classified into different categories according to the movement characteristic that was being measured. These kinematic metrics provide the starting point for a proposed objective metrics for the functional assessment of the upper extremity in people with movement disorders as a consequence of neurological injuries. Potential areas of future and further research are presented in the Discussion section. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Quantitative computed tomography measures of emphysema and airway wall thickness are related to respiratory symptoms

    DEFF Research Database (Denmark)

    Grydeland, Thomas B; Dirksen, Asger; Coxson, Harvey O

    2010-01-01

    There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness.......There is limited knowledge about the relationship between respiratory symptoms and quantitative high-resolution computed tomography measures of emphysema and airway wall thickness....

  17. Quantitative mixture fraction measurements in combustion system via laser induced breakdown spectroscopy

    KAUST Repository

    Mansour, Mohy S.; Imam, Hisham; Elsayed, Khaled A.; Elbaz, Ayman M.; Abbass, Wafaa

    2015-01-01

    Laser induced breakdown spectroscopy (LIBS) technique has been applied to quantitative mixture fraction measurements in flames. The measured spectra of different mixtures of natural gas and air are used to obtain the calibration parameters for local

  18. Semi-automatic quantitative measurements of intracranial internal carotid artery stenosis and calcification using CT angiography

    International Nuclear Information System (INIS)

    Bleeker, Leslie; Berg, Rene van den; Majoie, Charles B.; Marquering, Henk A.; Nederkoorn, Paul J.

    2012-01-01

    Intracranial carotid artery atherosclerotic disease is an independent predictor for recurrent stroke. However, its quantitative assessment is not routinely performed in clinical practice. In this diagnostic study, we present and evaluate a novel semi-automatic application to quantitatively measure intracranial internal carotid artery (ICA) degree of stenosis and calcium volume in CT angiography (CTA) images. In this retrospective study involving CTA images of 88 consecutive patients, intracranial ICA stenosis was quantitatively measured by two independent observers. Stenoses were categorized with cutoff values of 30% and 50%. The calcification in the intracranial ICA was qualitatively categorized as absent, mild, moderate, or severe and quantitatively measured using the semi-automatic application. Linear weighted kappa values were calculated to assess the interobserver agreement of the stenosis and calcium categorization. The average and the standard deviation of the quantitative calcium volume were calculated for the calcium categories. For the stenosis measurements, the CTA images of 162 arteries yielded an interobserver correlation of 0.78 (P < 0.001). Kappa values of the categorized stenosis measurements were moderate: 0.45 and 0.58 for cutoff values of 30% and 50%, respectively. The kappa value for the calcium categorization was 0.62, with a good agreement between the qualitative and quantitative calcium assessment. Quantitative degree of stenosis measurement of the intracranial ICA on CTA is feasible with a good interobserver agreement ICA. Qualitative calcium categorization agrees well with quantitative measurements. (orig.)

  19. Opportunities for measuring DNA synthesis time by quantitative autoradiography

    International Nuclear Information System (INIS)

    Vasileva, D.

    1980-01-01

    DNA sysntesis time (Tsub(s)) in cells of the canine erythropoiesis and myelopoiesis pools was determined by quantitative autoradiography according to Doermer. In contrast to mitosis labelling for Tsub(s) estimation as so far applied, this technique uses well-differentiated cells. After blocking endogeneous DNA synthesis with 5-fluorodeoxyuridine, its further course becomes dependent on exogeneous supply of thymidine, in the form of 14 C-thymidine. From incroporation of the latter into the individual cell within a definite time span (3-7 min) and taking into account its total amount, Tsub(s) may be calculated. The data thus obtained were found to agree with Tsub(s) values as estimated from the labelled mitosis curve

  20. Quantitative measurement of hypertrophic scar: interrater reliability and concurrent validity.

    Science.gov (United States)

    Nedelec, Bernadette; Correa, José A; Rachelska, Grazyna; Armour, Alexis; LaSalle, Léo

    2008-01-01

    Research into the pathophysiology and treatment of hypertrophic scar (HSc) remains limited by the heterogeneity of scar and the imprecision with which its severity is measured. The objective of this study was to test the interrater reliability and concurrent validity of the Cutometer measurement of elasticity, the Mexameter measurement of erythema and pigmentation, and total thickness measure of the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar, and HSc. Three independent investigators evaluated 128 sites (severe HSc, moderate or mild HSc, donor site, and normal skin) on 32 burn survivors using all of the above measurement tools. The intraclass correlation coefficient, which was used to measure interrater reliability, reflects the inherent amount of error in the measure and is considered acceptable when it is >0.75. Interrater reliability of the totals of the height, pliability, and vascularity subscales of the mVSS fell below the acceptable limit ( congruent with0.50). The individual subscales of the mVSS fell well below the acceptable level (0.89) for each study site with the exception of severe scar. Mexameter and DermaScan C reliability measurements were acceptable for all sites (>0.82). Concurrent validity correlations with the mVSS were significant except for the comparison of the mVSS pliability subscale and the Cutometer maximum deformation measure comparison in severe scar. In conclusion, the Mexameter and DermaScan C measurements of scar color and thickness of all sites, as well as the Cutometer measurement of elasticity in all but the most severe scars shows high interrater reliability. Their significant concurrent validity with the mVSS confirms that these tools are measuring the same traits as the mVSS, and in a more objective way.

  1. Quantitative comparison of measurements of urgent care service quality.

    Science.gov (United States)

    Qin, Hong; Prybutok, Victor; Prybutok, Gayle

    2016-01-01

    Service quality and patient satisfaction are essential to health care organization success. Parasuraman, Zeithaml, and Berry introduced SERVQUAL, a prominent service quality measure not yet applied to urgent care. We develop an instrument to measure perceived service quality and identify the determinants of patient satisfaction/ behavioral intentions. We examine the relationships among perceived service quality, patient satisfaction and behavioral intentions, and demonstrate that urgent care service quality is not equivalent using measures of perceptions only, differences of expectations minus perceptions, ratio of perceptions to expectations, and the log of the ratio. Perceptions provide the best measure of urgent care service quality.

  2. A method for quantitative measurement of lumbar intervertebral disc structures

    DEFF Research Database (Denmark)

    Tunset, Andreas; Kjær, Per; Samir Chreiteh, Shadi

    2013-01-01

    There is a shortage of agreement studies relevant for measuring changes over time in lumbar intervertebral disc structures. The objectives of this study were: 1) to develop a method for measurement of intervertebral disc height, anterior and posterior disc material and dural sac diameter using MR...

  3. Quantitative measures of walking and strength provide insight into brain corticospinal tract pathology in multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Nora E Fritz

    2017-01-01

    Quantitative measures of strength and walking are associated with brain corticospinal tract pathology. The addition of these quantitative measures to basic clinical information explains more of the variance in corticospinal tract fractional anisotropy and magnetization transfer ratio than the basic clinical information alone. Outcome measurement for multiple sclerosis clinical trials has been notoriously challenging; the use of quantitative measures of strength and walking along with tract-specific imaging methods may improve our ability to monitor disease change over time, with intervention, and provide needed guidelines for developing more effective targeted rehabilitation strategies.

  4. A simple measurement hammer for quantitative reflex studies

    NARCIS (Netherlands)

    Stam, J.; van Leeuwen, J. R.

    1984-01-01

    A reflex hammer for measurement of the mechanical stimulus strength was designed. Combined with standard EMG equipment this instrument permits the study of both stimulus-response relations and latencies of myotatic reflexes. Some results in normal subjects are discussed

  5. Quantitative measurement of holographic image quality using Adobe Photoshop

    International Nuclear Information System (INIS)

    Wesly, E

    2013-01-01

    Measurement of the characteristics of image holograms in regards to diffraction efficiency and signal to noise ratio are demonstrated, using readily available digital cameras and image editing software. Illustrations and case studies, using currently available holographic recording materials, are presented.

  6. Quantitative measurement of holographic image quality using Adobe Photoshop

    Science.gov (United States)

    Wesly, E.

    2013-02-01

    Measurement of the characteristics of image holograms in regards to diffraction efficiency and signal to noise ratio are demonstrated, using readily available digital cameras and image editing software. Illustrations and case studies, using currently available holographic recording materials, are presented.

  7. Usefulness of quantitative SPECT in unilateral temporomandibular joint disorder: correlation with signs and symptoms

    International Nuclear Information System (INIS)

    Kim, Ho Sung; Jeong, Jong Cheol; Kim, Keon Jung; Choi, Jae Sun; Sung, Dae Kyung; Lee, Gye Huyk; Kim, Jong Ho

    1998-01-01

    The aims of this study was to compare the diagnostic accuracy of Conventional Radiography (CR). Radionuclide Angiography (RNA). Planar Scintigraphy (PS) and Single Photon Emission Computed Tomography (SPECT) for the evaluation of temporomandibular joint (TMJ) disorder; and to show whether technetium-99m-MDP uptake on quantitative SPECT correlated with the symptom and/or signs. Three Phase Bone Scintigraphy (TPBS) and SPECT of both TMJ were performed in 51 patients (M : F = 10 : 41 mean age= 30.4 :28.6, respectively) with unilateral TMJ disorder after an intravenous injection of 25 mCi (925 MBq) of 99mTc-MDP. Data were analyzed by creating three regions of interest (ROIs) over designated areas both on the PS and SPECT: Lesion (L). Non-lesion(NL) which is contralateral to L and Background (BG). L/ NL and L/BG (=[(L-BG)/500,000] x 100 (%)] ratios were calculated for each patients. L/NL ratios on SPECT were compared according to the symptom/signs or not. There was a fair correlation of L/N values between three slice-and seven slice-added SPECT images (r=0.5124, p=0.006, y=0.5588 + 0.5414X). The percentages of symptoms or signs were: pain (76.5%), mouth opening limitation (49.0%), joint sound (39.2%), discomfort (43.1%), headache(27.5%), neck stiffness (21.6%), closed lock (5.9%) / tenderness (47.1%), joint click (54.9%) and limitation of maximum mouth opening (45.1%). The Sensitive of SPECT(86.3%) was better than PS(66.7%), RNA(27.5%), and CR(26.3%). According to the presence of symptom/sign or not, comparative analysis of L/NL ratios on SPECT showed a fair correlation in pain (1.16 : 1.11) mouth opening limitation (1.21 : 1.09), joint sound (1.19 : 1.08), discomfort (1.22 : 1.09), headache (1.19: 1.13), tenderness (1.16 : 1.14) and limitation of maximum mouth opening (1.16 : 1.13), but little correlation in neck stiffness (1.12 : 1.15), closed lock (1.06 : 1.15), dislocation (1.08 : 1.15) joint click (1.12 : 1.18). In conclusion, quantitative SPECT is the noninvasive

  8. Quantitative convergent beam electron diffraction measurements of bonding in alumina

    International Nuclear Information System (INIS)

    Johnson, A.W.S.

    2002-01-01

    Full text: The QCBED technique of measuring accurate structure factors has been made practical by advances in energy filtering, computing and in the accurate measurement of intensity. Originally attempted in 1965 by the late Peter Goodman (CSIRO, Melbourne) while working with Gunter Lehmpfuhl (Fritz Haber Institut, Berlin), QCBED has been successfully developed and tested in the last decade on simple structures such as Si and MgO. Our work on Alumina is a step up in complexity and has shown that extinction in X-ray diffraction is not correctable to the precision required. In combination with accurate X-ray diffraction, QCBED promises to revolutionize the accuracy of bonding charge density measurements, experimental results which are of significance in the development of Density Functional Theory used in predictive chemistry. Copyright (2002) Australian Society for Electron Microscopy Inc

  9. Cultural Values Predicting Acculturation Orientations: Operationalizing a Quantitative Measure

    Science.gov (United States)

    Ehala, Martin

    2012-01-01

    This article proposes that acculturation orientations are related to two sets of cultural values: utilitarianism (Ut) and traditionalism (Tr). While utilitarian values enhance assimilation, traditional values support language and identity maintenance. It is proposed that the propensity to either end of this value opposition can be measured by an…

  10. Quantitative Spectral Radiance Measurements in the HYMETS Arc Jet

    Science.gov (United States)

    Danehy, Paul M.; Hires, Drew V.; Johansen, Craig T.; Bathel, Brett F.; Jones, Stephen B.; Gragg, Jeffrey G.; Splinter, Scott C.

    2012-01-01

    Calibrated spectral radiance measurements of gaseous emission spectra have been obtained from the HYMETS (Hypersonic Materials Environmental Test System) 400 kW arc-heated wind tunnel at NASA Langley Research Center. A fiber-optic coupled spectrometer collected natural luminosity from the flow. Spectral radiance measurements are reported between 340 and 1000 nm. Both Silicon Carbide (SiC) and Phenolic Impregnated Carbon Ablator (PICA) samples were placed in the flow. Test gases studied included a mostly-N2 atmosphere (95% nitrogen, 5% argon), a simulated Earth Air atmosphere (75% nitrogen, 20% oxygen, 5% argon) and a simulated Martian atmosphere (71% carbon dioxide, 24% nitrogen, 5% argon). The bulk enthalpy of the flow was varied as was the location of the measurement. For the intermediate flow enthalpy tested (20 MJ/kg), emission from the Mars simulant gas was about 10 times higher than the Air flow and 15 times higher than the mostly-N2 atmosphere. Shock standoff distances were estimated from the spectral radiance measurements. Within-run, run-to-run and day-to-day repeatability of the emission were studied, with significant variations (15-100%) noted.

  11. Measuring thin films using quantitative frustrated total internal reflection (FTIR)

    NARCIS (Netherlands)

    Shirota, Minori; van Limbeek, Michiel A.J.; Lohse, Detlef; Sun, Chao

    2017-01-01

    Abstract.: In the study of interactions between liquids and solids, an accurate measurement of the film thickness between the two media is essential to study the dynamics. As interferometry is restricted by the wavelength of the light source used, recent studies of thinner films have prompted the

  12. Reproducibility of Quantitative Structural and Physiological MRI Measurements

    Science.gov (United States)

    2017-08-09

    project.org/) and SPSS (IBM Corp., Armonk, NY) for data analysis. Mean and confidence inter- vals for each measure are found in Tables 1–7. To assess...visits, and was calculated using a two- way mixed model in SPSS MCV and MRD values closer to 0 are considered to be the most reproducible, and ICC

  13. Quantitative measures of CRE and its link with organizational performance

    NARCIS (Netherlands)

    Appel - Meulenbroek, H.A.J.A.

    2007-01-01

    For CREM (Corporate Real Estate Management) to be able to deliver added value to its client organisation, it has to know 1) which CRE aspects influence its employees, processes, machinery, visitors, etc, 2) how these aspects influence performance and 3) how to measure and manage them. Analysis of

  14. CONFOCAL MICROSCOPY SYSTEM PERFORMANCE: FOUNDATIONS FOR MEASUREMENTS, QUANTITATION AND SPECTROSCOPY

    Science.gov (United States)

    The confocal laser-scanning microscopy (CLSM) has enormous potential in many biological fields. The goal of a CLSM is to acquire and quantify fluorescence and in some instruments acquire spectral characterization of the emitted signal. The accuracy of these measurements demands t...

  15. Quantitative approach to measuring the cerebrospinal fluid space with CT

    Energy Technology Data Exchange (ETDEWEB)

    Zeumer, H.; Hacke, W.; Hartwich, P.

    1982-01-01

    A method for measuring the subarachnoid space by using an independent CT evaluation unit is described. The normal values have been calculated for patients, according to age, and three examples are presented demonstrating reversible decrease of brain volume in patients suffering anorexia nervosa and chronic alcoholism.

  16. Quantitative measurement of hypertrophic scar: intrarater reliability, sensitivity, and specificity.

    Science.gov (United States)

    Nedelec, Bernadette; Correa, José A; Rachelska, Grazyna; Armour, Alexis; LaSalle, Léo

    2008-01-01

    The comparison of scar evaluation over time requires measurement tools with acceptable intrarater reliability and the ability to discriminate skin characteristics of interest. The objective of this study was to evaluate the intrarater reliability and sensitivity and specificity of the Cutometer, the Mexameter, and the DermaScan C relative to the modified Vancouver Scar Scale (mVSS) in patient-matched normal skin, normal scar (donor sites), and hypertrophic scar (HSc). A single investigator evaluated four tissue types (severe HSc, less severe HSc, donor site, and normal skin) in 30 burn survivors with all four measurement tools. The intraclass correlation coefficient (ICC) for the Cutometer was acceptable (> or =0.75) for the maximum deformation measure for the donor site and normal skin (>0.78) but was below the acceptable range for the HSc sites and all other parameters. The ICC for the Mexameter erythema (>0.75) and melanin index (>0.89) and the DermaScan C total thickness measurement (>0.82) were acceptable for all sites. The ICC for the total of the height, pliability, and vascularity subscales of the mVSS was acceptable (0.81) for normal scar but below the acceptable range for the scar sites. The DermaScan C was clearly able to discriminate HSc from normal scar and normal skin based on the total thickness measure. The Cutometer was less discriminating but was still able to discriminate HSc from normal scar and normal skin. The Mexameter erythema index was not a good discriminator of HSc and normal scar. Receiver operating characteristic curves were generated to establish the best cutoff point for the DermaScan C total thickness and the Cutometer maximum deformation, which were 2.034 and 0.387 mm, respectively. This study showed that although the Cutometer, the DermaScan C, and the Mexameter have measurement properties that make them attractive substitutes for the mVSS, caution must be used when interpreting results since the Cutometer has a ceiling effect when

  17. Challenge in Enhancing the Teaching and Learning of Variable Measurements in Quantitative Research

    Science.gov (United States)

    Kee, Chang Peng; Osman, Kamisah; Ahmad, Fauziah

    2013-01-01

    Statistical analysis is one component that cannot be avoided in a quantitative research. Initial observations noted that students in higher education institution faced difficulty analysing quantitative data which were attributed to the confusions of various variable measurements. This paper aims to compare the outcomes of two approaches applied in…

  18. Quantitative measurement of ventricular dilatation on CT scan

    International Nuclear Information System (INIS)

    Okita, Naoshi; Mochizuki, Hiroshi; Takase, Sadao

    1985-01-01

    Cerebral atrophy might be judged from the ventricular dilatation with some indices, calculated from various ventricular width. But, there is no general agreement on what index is the most reliable. In this paper, we attempted to establish the index, easy to measure and most reliable. Our method is as follow. 1) We carried out the CT scan (EMI 1010) on 89 neurologically intact patients. Scans were parallel to orbito-meatal line (OML), and were 10 mm in thickness. On CT scan films, various width, area of anterior horns and area of bodies of lateral ventricles were measured. Measurement about the anterior horns of lateral ventricles were carried out on image the most clearly showed the foramen of Monro. And measurements about the bodies of lateral ventricles were on image, 20 mm above the image of anterior horn. Correlations of various width and areas were calculated. Then we proposed new indices with high correlations (over 0.9) with ventricular area; Anterior horn CVI (Cerebro-Ventricular Index) and Body CVI. 2) Patients with myotonic dystrophy show cerebral atrophy. We carried out the CT scan (GECT/T 8800) on 17 myotonic dystrophy patients and 30 controls. Between the two groups, age and sex were almost matched. In the two groups, we calculated our new indices as well as various indices which have been reported; Huckman number, Bifrontal CVI, Bicaudal CVI, Anterior horn index, Hirajima's index, and Cella-media index. The data were analyzed statistically. The ventricular dilatation of myotonic dystrophy patients is more definite with Anterior horn CVI, Bicaudal CVI and Body CVI (p<0.01). These indices have higher correlations with the ventricular area (about 0.9). (J.P.N.)

  19. Measurements in quantitative research: how to select and report on research instruments.

    Science.gov (United States)

    Hagan, Teresa L

    2014-07-01

    Measures exist to numerically represent degrees of attributes. Quantitative research is based on measurement and is conducted in a systematic, controlled manner. These measures enable researchers to perform statistical tests, analyze differences between groups, and determine the effectiveness of treatments. If something is not measurable, it cannot be tested.

  20. Phase transition traced by conductivity measurements: quantitative analysis

    DEFF Research Database (Denmark)

    Keding, Ralf; Ruessel, Christian; Tauch, Diana

    2008-01-01

    to the electrodes, all in a cylindrical geometry. The electrical resistivity of a sample in the system BaAl2B2O7 was measured during cooling between liquidus temperature (T-l) and transformation temperature (T-g) using a fixed frequency of 3.7 Hz. The melt crystallised in this temperature range during cooling...... of conductivity and the resistance changes caused by phase transformation. This enables to determine the crystal growth velocity in the temperature range between 750 and 860 degrees C in a single experiment....

  1. Quantitative measurement of the orbital angular momentum density of light

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2012-03-01

    Full Text Available of the azimuthal mode index, n, on LCD1 is equiva- lent to n on LCD2. If the reader wishes to orientate the experimental setup differently, such that the two SLMs have the same orientation (i.e., are not mirror images of each other), the complex conjugate... measurement, is separated into two parts: (1) the generation of the optical field and (2) the mea- surement of the OAM density, which is achieved by performing a modal decomposition of the opti- cal field. A. Symmetric Superposition of Two Bessel Beams...

  2. Development of a Quantitative Measure of Holistic Nursing Care.

    Science.gov (United States)

    Kinchen, Elizabeth

    2015-09-01

    Holistic care has long been a defining attribute of nursing practice. From the earliest years of its formal history, nursing has favored a holistic approach in the care of patients, and such an approach has become more important over time. The expansion of nursing's responsibility in delivering comprehensive primary care, the recognition of the importance of relationship-centered care, and the need for evidence-based legitimation of holistic nursing care and practices to insurance companies, policy-makers, health care providers, and patients highlight the need to examine the holistic properties of nursing care. The Holistic Caring Inventory is a theoretically sound, valid, and reliable tool; however, it does not comprehensively address attributes that have come to define holistic nursing care, necessitating the development of a more current instrument to measure the elements of a holistic perspective in nursing care. The development of a current and more comprehensive measure of holistic nursing care may be critical in demonstrating the importance of a holistic approach to patient care that reflects the principles of relationship-based care, shared decision-making, authentic presence, and pattern recognition. © The Author(s) 2014.

  3. Laser-induced incandescence: Towards quantitative soot volume fraction measurements

    Energy Technology Data Exchange (ETDEWEB)

    Tzannis, A P; Wienbeucker, F; Beaud, P; Frey, H -M; Gerber, T; Mischler, B; Radi, P P [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1999-08-01

    Laser-Induced Incandescence has recently emerged as a versatile tool for measuring soot volume fraction in a wide range of combustion systems. In this work we investigate the essential features of the method. LII is based on the acquisition of the incandescence of soot when heated through a high power laser pulse. Initial experiments have been performed on a model laboratory flame. The behaviour of the LII signal is studied experimentally. By applying numerical calculations we investigate the possibility to obtain two-dimensional soot volume fraction distributions. For this purpose a combination of LII with other techniques is required. This part is discussed in some extent and the future work is outlined. (author) 4 figs., 3 refs.

  4. Quantitative measurement of interocular suppression in children with amblyopia.

    Science.gov (United States)

    Narasimhan, Sathyasri; Harrison, Emily R; Giaschi, Deborah E

    2012-08-01

    In this study we explored the possibility of using a dichoptic global motion technique to measure interocular suppression in children with amblyopia. We compared children (5-16 years old) with unilateral anisometropic and/or strabismic amblyopia to age-matched control children. Under dichoptic viewing conditions, contrast interference thresholds were determined with a global motion direction-discrimination task. Using virtual reality goggles, high contrast signal dots were presented to the amblyopic eye, while low contrast noise dots were presented to the non-amblyopic fellow eye. The contrast of the noise dots was increased until discrimination of the motion direction of the signal dots reached chance performance. Contrast interference thresholds were significantly lower in the strabismic group than in the anisometropic and control group. Our results suggest that interocular suppression is stronger in strabismic than in anisometropic amblyopia. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Phase transition traced by conductivity measurements: quantitative analysis

    DEFF Research Database (Denmark)

    Keding, Ralf; Ruessel, Christian; Tauch, Diana

    2008-01-01

    starting from the electrodes. The change in the conductivity as a function of the temperature was fitted with VFT-equation for both the melt and the crystalline phase. An extrapolation of the resistance of the melt as well as of the crystalline material allows to separate the temperature dependent changes...... of conductivity and the resistance changes caused by phase transformation. This enables to determine the crystal growth velocity in the temperature range between 750 and 860 degrees C in a single experiment.......The measurement of the crystal growth velocity is carried out by analysing the change in the resistivity of the sample. The calculation of the crystal growth velocity is developed for crystal formation in the volume, crystal growth initiated at the electrodes as well as perpendicular...

  6. OPPORTUNISTIC ASPERGILLUS PATHOGENS MEASURED IN HOME AND HOSPITAL TAP WATER BY MOLD SPECIFIC QUANTITATIVE PCR (MSQPCR)

    Science.gov (United States)

    Opportunistic fungal pathogens are a concern because of the increasing number of immunocompromised patients. The goal of this research was to test a simple extraction method and rapid quantitative PCR (QPCR) measurement of the occurrence of potential pathogens, Aspergillus fumiga...

  7. Quantitative CT measures of emphysema and airway wall thickness are related to D(L)CO

    DEFF Research Database (Denmark)

    Grydeland, Thomas B; Thorsen, Einar; Dirksen, Asger

    2011-01-01

    There is limited knowledge on the relationship between diffusing capacity of the lung for carbon monoxide (D(L)CO) and quantitative computed tomography (CT) measures of emphysema and airway wall thickness.......There is limited knowledge on the relationship between diffusing capacity of the lung for carbon monoxide (D(L)CO) and quantitative computed tomography (CT) measures of emphysema and airway wall thickness....

  8. Quantitative fundus autofluorescence in mice: correlation with HPLC quantitation of RPE lipofuscin and measurement of retina outer nuclear layer thickness.

    Science.gov (United States)

    Sparrow, Janet R; Blonska, Anna; Flynn, Erin; Duncker, Tobias; Greenberg, Jonathan P; Secondi, Roberta; Ueda, Keiko; Delori, François C

    2013-04-17

    Our study was conducted to establish procedures and protocols for quantitative autofluorescence (qAF) measurements in mice, and to report changes in qAF, A2E bisretinoid concentration, and outer nuclear layer (ONL) thickness in mice of different genotypes and age. Fundus autofluorescence (AF) images (55° lens, 488 nm excitation) were acquired in albino Abca4(-/-), Abca4(+/-), and Abca4(+/+) mice (ages 2-12 months) with a confocal scanning laser ophthalmoscope (cSLO). Gray levels (GLs) in each image were calibrated to an internal fluorescence reference. The bisretinoid A2E was measured by quantitative high performance liquid chromatography (HPLC). Histometric analysis of ONL thicknesses was performed. The Bland-Altman coefficient of repeatability (95% confidence interval) was ±18% for between-session qAF measurements. Mean qAF values increased with age (2-12 months) in all groups of mice. qAF was approximately 2-fold higher in Abca4(-/-) mice than in Abca4(+/+) mice and approximately 20% higher in heterozygous mice. HPLC measurements of the lipofuscin fluorophore A2E also revealed age-associated increases, and the fold difference between Abca4(-/-) and wild-type mice was more pronounced (approximately 3-4-fold) than measurable by qAF. Moreover, A2E levels declined after 8 months of age, a change not observed with qAF. The decline in A2E levels in the Abca4(-/-) mice corresponded to reduced photoreceptor cell viability as reflected in ONL thinning beginning at 8 months of age. The qAF method enables measurement of in vivo lipofuscin and the detection of genotype and age-associated differences. The use of this approach has the potential to aid in understanding retinal disease processes and will facilitate preclinical studies.

  9. Quantitative and qualitative measures of decomposition: Is there a link?

    Energy Technology Data Exchange (ETDEWEB)

    Eaton, Robert, J.; Sanchez, Felipe, G.

    2009-03-01

    Decomposition rates of loblolly pine coarse woody debris (CWD) were determined by mass loss and wood density changes for trees that differed in source of mortality (natural, girdle-poison, and felling). Specifically, three treatments were examined: (1) control (CON): natural mortality; (2) CD: 5-fold increase in CWD compared with the CON; and (3) CS: 12-fold increase in snags compared with the CON. The additional CWD in the CD treatment plots and the additional snags in the CS plots were achieved by felling (for the CD plots) or girdling followed by herbicide injection (for the CS plots) select trees in these plots. Consequently,mortality on the CD plots is due to natural causes and felling. Likewise, mortality on the CS plots is due to natural causes and girdle-poison. In each treatment plot, mortality due to natural causes was inventoried since 1997, whereas mortality due to girdle-poison and felling were inventoried since 2001. No significant difference was detected between the rates of decomposition for the CWD on these treatment plots, indicating that source of the tree mortality did not influence rates of decomposition once the tree fell. These experimental measures of decomposition were compared with two decay classification systems (three- and five-unit classifications) to determine linkages. Changes in wood density did not correlate to any decay classification, whereas mass loss had a weak correlation with decay class. However, the large degree of variation limits the utility of decay classification systems in estimating mass loss.

  10. Abnormal Resting-State Quantitative Electroencephalogram in Children With Central Auditory Processing Disorder: A Pilot Study.

    Science.gov (United States)

    Milner, Rafał; Lewandowska, Monika; Ganc, Małgorzata; Włodarczyk, Elżbieta; Grudzień, Diana; Skarżyński, Henryk

    2018-01-01

    In this study, we showed an abnormal resting-state quantitative electroencephalogram (QEEG) pattern in children with central auditory processing disorder (CAPD). Twenty-seven children (16 male, 11 female; mean age = 10.7 years) with CAPD and no symptoms of other developmental disorders, as well as 23 age- and sex-matched, typically developing children (TDC, 11 male, 13 female; mean age = 11.8 years) underwent examination of central auditory processes (CAPs) and QEEG evaluation consisting of two randomly presented blocks of "Eyes Open" (EO) or "Eyes Closed" (EC) recordings. Significant correlations between individual frequency band powers and CAP tests performance were found. The QEEG studies revealed that in CAPD relative to TDC there was no effect of decreased delta absolute power (1.5-4 Hz) in EO compared to the EC condition. Furthermore, children with CAPD showed increased theta power (4-8 Hz) in the frontal area, a tendency toward elevated theta power in EO block, and reduced low-frequency beta power (12-15 Hz) in the bilateral occipital and the left temporo-occipital regions for both EO and EC conditions. Decreased middle-frequency beta power (15-18 Hz) in children with CAPD was observed only in the EC block. The findings of the present study suggest that QEEG could be an adequate tool to discriminate children with CAPD from normally developing children. Correlation analysis shows relationship between the individual EEG resting frequency bands and the CAPs. Increased power of slow waves and decreased power of fast rhythms could indicate abnormal functioning (hypoarousal of the cortex and/or an immaturity) of brain areas not specialized in auditory information processing.

  11. Abnormal Resting-State Quantitative Electroencephalogram in Children With Central Auditory Processing Disorder: A Pilot Study

    Science.gov (United States)

    Milner, Rafał; Lewandowska, Monika; Ganc, Małgorzata; Włodarczyk, Elżbieta; Grudzień, Diana; Skarżyński, Henryk

    2018-01-01

    In this study, we showed an abnormal resting-state quantitative electroencephalogram (QEEG) pattern in children with central auditory processing disorder (CAPD). Twenty-seven children (16 male, 11 female; mean age = 10.7 years) with CAPD and no symptoms of other developmental disorders, as well as 23 age- and sex-matched, typically developing children (TDC, 11 male, 13 female; mean age = 11.8 years) underwent examination of central auditory processes (CAPs) and QEEG evaluation consisting of two randomly presented blocks of “Eyes Open” (EO) or “Eyes Closed” (EC) recordings. Significant correlations between individual frequency band powers and CAP tests performance were found. The QEEG studies revealed that in CAPD relative to TDC there was no effect of decreased delta absolute power (1.5–4 Hz) in EO compared to the EC condition. Furthermore, children with CAPD showed increased theta power (4–8 Hz) in the frontal area, a tendency toward elevated theta power in EO block, and reduced low-frequency beta power (12–15 Hz) in the bilateral occipital and the left temporo-occipital regions for both EO and EC conditions. Decreased middle-frequency beta power (15–18 Hz) in children with CAPD was observed only in the EC block. The findings of the present study suggest that QEEG could be an adequate tool to discriminate children with CAPD from normally developing children. Correlation analysis shows relationship between the individual EEG resting frequency bands and the CAPs. Increased power of slow waves and decreased power of fast rhythms could indicate abnormal functioning (hypoarousal of the cortex and/or an immaturity) of brain areas not specialized in auditory information processing.

  12. Orbital benign and malignant lymphoproliferative disorders: Differentiation using semi-quantitative and quantitative analysis of dynamic contrast-enhanced magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hu, Hao; Xu, Xiao-Quan; Liu, Hu; Hong, Xun-Ning; Shi, Hai-Bin; Wu, Fei-Yun

    2017-01-01

    Objectives: To assess the value of dynamic contrast-enhanced MR imaging (DCE-MRI) in differentiating benign from malignant orbital lymphoproliferative disorders (OLPDs). Methods: Thirty-nine patients with orbital lymphoproliferative disorders (21 malignant and 18 benign) underwent DCE-MRI scan for pre-treatment evaluation from March 2013 to December 2015. Both semi-quantitative (TTP, AUC, Slope max ) and quantitative (K trans , k ep , v e ) parameters were calculated, and compared between two groups. Receiver operating characteristic (ROC) curve analyses were used to determine the diagnostic value of each significant parameter. Results: Malignant OLPDs showed significantly higher k ep , lower v e , and lower AUC than benign OLPDs, while no significant differences were found on K trans , TTP and Slope max . ROC analyses indicated that v e exhibited the best diagnostic performance in predicting malignant OLPDs (cutoff value, 0.211; area under the curve, 0.896; sensitivity, 76.2%; specificity, 94.9%), followed by k ep (cutoff value, 0.853; area under the curve, 0.839; sensitivity, 85.7%; specificity, 89.9%). Conclusion: DCE-MRI and specially its derived quantitative parameters of k ep and v e are promising metrics for differentiating malignant from benign OLPDs.

  13. Orbital benign and malignant lymphoproliferative disorders: Differentiation using semi-quantitative and quantitative analysis of dynamic contrast-enhanced magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Hao; Xu, Xiao-Quan [Department of Radiology, First Affiliated Hospital of Nanjing Medical University, Nanjing (China); Liu, Hu [Department of Ophthalmology, First Affiliated Hospital of Nanjing Medical University, Nanjing (China); Hong, Xun-Ning; Shi, Hai-Bin [Department of Radiology, First Affiliated Hospital of Nanjing Medical University, Nanjing (China); Wu, Fei-Yun, E-mail: wfydd_njmu@163.com [Department of Radiology, First Affiliated Hospital of Nanjing Medical University, Nanjing (China)

    2017-03-15

    Objectives: To assess the value of dynamic contrast-enhanced MR imaging (DCE-MRI) in differentiating benign from malignant orbital lymphoproliferative disorders (OLPDs). Methods: Thirty-nine patients with orbital lymphoproliferative disorders (21 malignant and 18 benign) underwent DCE-MRI scan for pre-treatment evaluation from March 2013 to December 2015. Both semi-quantitative (TTP, AUC, Slope{sub max}) and quantitative (K{sup trans}, k{sub ep}, v{sub e}) parameters were calculated, and compared between two groups. Receiver operating characteristic (ROC) curve analyses were used to determine the diagnostic value of each significant parameter. Results: Malignant OLPDs showed significantly higher k{sub ep}, lower v{sub e}, and lower AUC than benign OLPDs, while no significant differences were found on K{sup trans}, TTP and Slope{sub max}. ROC analyses indicated that v{sub e} exhibited the best diagnostic performance in predicting malignant OLPDs (cutoff value, 0.211; area under the curve, 0.896; sensitivity, 76.2%; specificity, 94.9%), followed by k{sub ep} (cutoff value, 0.853; area under the curve, 0.839; sensitivity, 85.7%; specificity, 89.9%). Conclusion: DCE-MRI and specially its derived quantitative parameters of k{sub ep} and v{sub e} are promising metrics for differentiating malignant from benign OLPDs.

  14. Quantitative metacarpal bone measurements before and after renal transplantation

    International Nuclear Information System (INIS)

    Andresen, J.; Nielsen, H.E.; Kommunehospitalet, Aarhus

    1986-01-01

    The outer (D) and inner diameter (d) of the second metacarpal bone, the combined cortical thickness (D-d), cortical area (D 2 -d 2 ) and bone mass ((D 2 d 2 /D 2 ) were measured in 74 renal transplant (RT) recipients at the time of renal transplantation and in a prospective analysis of 60 recipients after transplantation. The RT patient group was made up of recipients who after renal transplanation developed osteonecrosis or spontaneous fractures (RT-ON/SF) and an age- and sex-matched renal control group of subjects who did not develop these complications (RT-C). At the time of renal transplantation, in renal transplant recipient men and women, significantly reduced values in D, D-d and D 2 -d 2 was noticed. These findings could be explained by a higher ratio of bone resoprtion than formation at the periosteal surface. Following renal transplantation, significant increases in d were seen with significant decreases in D-d, D 2 -d 2 and (D 2 -d 2 )/D 2 , probably due to endosteal bone resorption, whereas D was unchanged compared with normal control persons. In the total group and in RT-ON/SF women, D decreased significantly and in ON/SF, increased significantly with significant decrease in bone mass compared with normal women whereas no significant changes in the parameters were seen in RT-C women. These findings indicate that bone loss after transplantation continues at the periosteal surface in women. The bone loss was most markedly demonstrated in women, who subsequently develop osteonecrosis or spontaneous fractures, probably due to combined periosteal and endosteal resorption of calcified bony tissue. (orig.)

  15. Personality Disorders in Later Life: Questions about the Measurement, Course, and Impact of Disorders

    Science.gov (United States)

    Oltmanns, Thomas F.; Balsis, Steve

    2011-01-01

    Lifespan perspectives have played a crucial role in shaping our understanding of many forms of psychopathology. Unfortunately, little attention has been given to personality disorders in middle adulthood and later life. Several issues are responsible for this deficiency, including difficulty applying the diagnostic criteria for personality disorders to older people and challenges in identifying appropriate samples of older participants. The goal of this review is to explore the benefits of considering older adults in the study of personality disorders. Later life offers a unique opportunity for investigators to consider links between personality pathology and consequential outcomes in people’s lives. Many domains are relevant, including health, longevity, social adjustment, marital relationships, and the experience of major life events. We review each domain and consider ways in which the study of middle-aged and older adults challenges researchers to evaluate how personality disorders in general are defined and measured. PMID:21219195

  16. Measuring Theory of Mind in Adults with Autism Spectrum Disorder

    Science.gov (United States)

    Brewer, Neil; Young, Robyn L.; Barnett, Emily

    2017-01-01

    Deficits in Theory of Mind (ToM)--the ability to interpret others' beliefs, intentions and emotions--undermine the ability of individuals with Autism Spectrum Disorder (ASD) to interact in socially normative ways. This study provides psychometric data for the Adult-Theory of Mind (A-ToM) measure using video-scenarios based in part on Happé's…

  17. Optical Phase Measurements of Disorder Strength Link Microstructure to Cell Stiffness.

    Science.gov (United States)

    Eldridge, Will J; Steelman, Zachary A; Loomis, Brianna; Wax, Adam

    2017-02-28

    There have been sustained efforts on the part of cell biologists to understand the mechanisms by which cells respond to mechanical stimuli. To this end, many rheological tools have been developed to characterize cellular stiffness. However, measurement of cellular viscoelastic properties has been limited in scope by the nature of most microrheological methods, which require direct mechanical contact, applied at the single-cell level. In this article, we describe, to our knowledge, a new analysis approach for quantitative phase imaging that relates refractive index variance to disorder strength, a parameter that is linked to cell stiffness. Significantly, both disorder strength and cell stiffness are measured with the same phase imaging system, presenting a unique alternative for label-free, noncontact, single-shot imaging of cellular rheologic properties. To demonstrate the potential applicability of the technique, we measure phase disorder strength and shear stiffness across five cellular populations with varying mechanical properties and demonstrate an inverse relationship between these two parameters. The existence of this relationship suggests that predictions of cell mechanical properties can be obtained from examining the disorder strength of cell structure using this, to our knowledge, novel, noncontact technique. Copyright © 2017 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  18. Evaluation of airway protection: Quantitative timing measures versus penetration/aspiration score.

    Science.gov (United States)

    Kendall, Katherine A

    2017-10-01

    Quantitative measures of swallowing function may improve the reliability and accuracy of modified barium swallow (MBS) study interpretation. Quantitative study analysis has not been widely instituted, however, secondary to concerns about the time required to make measures and a lack of research demonstrating impact on MBS interpretation. This study compares the accuracy of the penetration/aspiration (PEN/ASP) scale (an observational visual-perceptual assessment tool) to quantitative measures of airway closure timing relative to the arrival of the bolus at the upper esophageal sphincter in identifying a failure of airway protection during deglutition. Retrospective review of clinical swallowing data from a university-based outpatient clinic. Swallowing data from 426 patients were reviewed. Patients with normal PEN/ASP scores were identified, and the results of quantitative airway closure timing measures for three liquid bolus sizes were evaluated. The incidence of significant airway closure delay with and without a normal PEN/ASP score was determined. Inter-rater reliability for the quantitative measures was calculated. In patients with a normal PEN/ASP score, 33% demonstrated a delay in airway closure on at least one swallow during the MBS study. There was no correlation between PEN/ASP score and airway closure delay. Inter-rater reliability for the quantitative measure of airway closure timing was nearly perfect (intraclass correlation coefficient = 0.973). The use of quantitative measures of swallowing function, in conjunction with traditional visual perceptual methods of MBS study interpretation, improves the identification of airway closure delay, and hence, potential aspiration risk, even when no penetration or aspiration is apparent on the MBS study. 4. Laryngoscope, 127:2314-2318, 2017. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  19. Lower limb motor restlessness in Asperger's disorder, measured using actometry.

    Science.gov (United States)

    Tuisku, Katinka; Tani, Pekka; Nieminen-von Wendt, Taina; von Wendt, Lennart; Holi, Matti Mikael; Porkka-Heiskanen, Tarja; Lauerma, Hannu; Lindberg, Nina; Appelberg, Björn; Wahlbeck, Kristian

    2004-08-30

    The movement disturbances and brain imaging findings in Asperger's disorder (AD) suggest a dopaminergic deficit in movement regulation. Movement disorders of different etiologies have been quantified and specified with actometry. We compared 10 AD patients with 10 healthy controls, measuring their rest-activities by actometry. The lower limb motor activity was significantly higher in the AD group. They also displayed a rhythmic, periodic movement pattern similar to akathisia. These findings suggest a hypothesis of idiopathic akathisia and a special sensitivity to adverse effects of neuroleptic drugs.

  20. New possibilities for quantitative measurements of regional cerebral blood flow with gold-195m

    International Nuclear Information System (INIS)

    Lindner, P.; Nickel, O.

    1985-01-01

    A previously reported theory for quantitative cerebral blood flow measurement for nondiffusible radiotracers has been applied to patients after stroke and to volunteers undergoing a mental stimulation exercise. The energy spectrum of gold-195m shows two strong photon peaks, one at an energy level of 68 keV and a second at an energy-level of 262 keV. The low energy peak is suitable for perfusion studies in lateral views of the hemispheres; no look-through effect is seen. The high energy level is good for studies in posterior-anterior positions. Parametric images for quantitative regional cerebral blood flow can be generated. The area of occluded vessels in the case of stroke can be detected. Quantitative activation patterns of cerebral blood flow during mental stimulation can be generated. The results prove that, not only with freely diffusible indicators like xenon but also with nondiffusible indicators, it is possible to measure quantitatively cerebral blood flow patterns

  1. Measurement error of a simplified protocol for quantitative sensory tests in chronic pain patients

    DEFF Research Database (Denmark)

    Müller, Monika; Biurrun Manresa, José; Limacher, Andreas

    2017-01-01

    BACKGROUND AND OBJECTIVES: Large-scale application of Quantitative Sensory Tests (QST) is impaired by lacking standardized testing protocols. One unclear methodological aspect is the number of records needed to minimize measurement error. Traditionally, measurements are repeated 3 to 5 times...

  2. Feasibility of Quantitative Ultrasound Measurement of the Heel Bone in People with Intellectual Disabilities

    Science.gov (United States)

    Mergler, S.; Lobker, B.; Evenhuis, H. M.; Penning, C.

    2010-01-01

    Low bone mineral density (BMD) and fractures are common in people with intellectual disabilities (ID). Reduced mobility in case of motor impairment and the use of anti-epileptic drugs contribute to the development of low BMD. Quantitative ultrasound (QUS) measurement of the heel bone is a non-invasive and radiation-free method for measuring bone…

  3. Quantitative laser-induced fluorescence measurements of nitric oxide in a heavy-duty Diesel engine

    NARCIS (Netherlands)

    Verbiezen, K.; Klein-Douwel, R. J. H.; van Viet, A. P.; Donkerbroek, A. J.; Meerts, W. L.; Dam, N. J.; ter Meulen, J. J.

    2007-01-01

    We present quantitative, in-cylinder, UV-laser-induced fluorescence measurements of nitric oxide in a heavy-duty Diesel engine. Processing of the raw fluorescence signals includes a detailed correction, based on additional measurements, for the effect of laser beam and fluorescence attenuation, and

  4. [Cholinesterases in total blood measured with a semiquantitative technique, and plasma or erythrocyte cholinesterases measured with quantitative techniques].

    Science.gov (United States)

    Carmona-Fonseca, Jaime

    2007-06-01

    An equivalence model which allows comparison of blood cholinesterase values, measured by Lovibond (semiquantitative technique), and Michel, EQM, Monotest (erythrocyte and plasma cholinesterases) values measured by quantitative techniques is required. The performance of Lovibond (Edson tintometric and Limperos & Ranta techniques) were compared with quantitative techniques. The experimental design was descriptive, cross-sectional, and prospective. From a working population (18-59 years) in Valle de Aburrá and Near East of Antioquia. 827 representative samples were chosen for their lack of exposure to cholinesterase-inhibiting plaguicides and affiliated to the Social Security System. (1) 827 workers were classified by Lovibond in four categories: 821 values with 75% of cholinesterase activity or greater (categories 75, 87.5 and 100%) and 6 with cholinesterase activity smaller than 75%. (2) With each quantitative method, the mean values of erythrocyte and plasmatic cholinesterase corresponding to the four values obtained with Lovibond were statistically different to each other. (3) The mean values of each quantitative technique increased when increased the tintometric method value. (4) Lovibond classified the low enzymatic erythrocyte activity very poorly (61-73%), but the classification of the low enzymatic plasma activity was almost completely in error (94-96%). The values of erythrocyte or plasma cholinesterase were adequately estimated by both the quantitative techniques of Michel and EQM and by Lovibond, but only when the enzymatic activity is normal. Lovibond, however, had a poor capacity to designate as "low" the values that were low according to the quantitative tests.

  5. Measuring treatment outcomes in gambling disorders: a systematic review.

    Science.gov (United States)

    Pickering, Dylan; Keen, Brittany; Entwistle, Gavin; Blaszczynski, Alex

    2018-03-01

    Considerable variation of outcome variables used to measure recovery in the gambling treatment literature has precluded effective cross-study evaluations and hindered the development of best-practice treatment methodologies. The aim of this systematic review was to describe current diffuse concepts of recovery in the gambling field by mapping the range of outcomes and measurement strategies used to evaluate treatments, and to identify more commonly accepted indices of recovery. A systematic search of six academic databases for studies evaluating treatments (psychological and pharmacological) for gambling disorders with a minimum 6-month follow-up. Data from eligible studies were tabulated and analysis conducted using a narrative approach. Guidelines of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) were adhered to. Thirty-four studies were reviewed systematically (RCTs = 17, comparative designs = 17). Sixty-three different outcome measures were identified: 25 (39.7%) assessed gambling-specific constructs, 36 (57.1%) assessed non-gambling specific constructs, and two instruments were used across both categories (3.2%). Self-report instruments ranged from psychometrically validated to ad-hoc author-designed questionnaires. Units of measurement were inconsistent, particularly in the assessment of gambling behaviour. All studies assessed indices of gambling behaviour and/or symptoms of gambling disorder. Almost all studies (n = 30; 88.2%) included secondary measures relating to psychiatric comorbidities, psychological processes linked to treatment approach, or global functioning and wellbeing. In research on gambling disorders, the incorporation of broader outcome domains that extend beyond disorder-specific symptoms and behaviours suggests a multi-dimensional conceptualization of recovery. Development of a single comprehensive scale to measure all aspects of gambling recovery could help to facilitate uniform reporting practices

  6. Performance measurement for co-occurring mental health and substance use disorders

    Directory of Open Access Journals (Sweden)

    Pincus Harold A

    2009-10-01

    Full Text Available Abstract Background Co-occurring mental health and substance use disorders (COD are the norm rather than the exception. It is therefore critical that performance measures are developed to assess the quality of care for individuals with COD irrespective of whether they seek care in mental health systems or substance abuse systems or both. Methods We convened an expert panel and asked them to rate a series of structure, process, and outcomes measures for COD using a structured evaluation tool with domains for importance, usefulness, validity, and practicality. Results We chose twelve measures that demonstrated promise for future pilot testing and refinement. The criteria that we applied to select these measures included: balance across structure, process, and outcome measures, quantitative ratings from the panelists, narrative comments from the panelists, and evidence the measure had been tested in a similar form elsewhere. Conclusion To be successful performance measures need to be developed in such a way that they align with needs of administrators and providers. Policymakers need to work with all stakeholders to establish a concrete agenda for developing, piloting and implementing performance measures that include COD. Future research could begin to consider strategies that increase our ability to use administrative coding in mental health and substance use disorder systems to efficiently capture quality relevant clinical data.

  7. Quantitative analysis of lattice disorder and crystallite size in organic semiconductor thin films

    KAUST Repository

    Rivnay, Jonathan; Noriega, Rodrigo; Kline, R. Joseph; Salleo, Alberto; Toney, Michael F.

    2011-01-01

    and qualitatively assess the amount and type of disorder present in a sample. While applied directly to organic systems, this methodology is general for the accurate deconvolution of crystalline size and lattice disorder for any material investigated

  8. Qualitative pattern classification of shear wave elastography for breast masses: How it correlates to quantitative measurements

    International Nuclear Information System (INIS)

    Yoon, Jung Hyun; Ko, Kyung Hee; Jung, Hae Kyoung; Lee, Jong Tae

    2013-01-01

    Objective: To determine the correlation of qualitative shear wave elastography (SWE) pattern classification to quantitative SWE measurements and whether it is representative of quantitative SWE values with similar performances. Methods: From October 2012 to January 2013, 267 breast masses of 236 women (mean age: 45.12 ± 10.54 years, range: 21–88 years) who had undergone ultrasonography (US), SWE, and subsequent biopsy were included. US BI-RADS final assessment and qualitative and quantitative SWE measurements were recorded. Correlation between pattern classification and mean elasticity, maximum elasticity, elasticity ratio and standard deviation were evaluated. Diagnostic performances of grayscale US, SWE parameters, and US combined to SWE values were calculated and compared. Results: Of the 267 breast masses, 208 (77.9%) were benign and 59 (22.1%) were malignant. Pattern classifications significantly correlated with all quantitative SWE measurements, showing highest correlation with maximum elasticity, r = 0.721 (P < 0.001). Sensitivity was significantly decreased in US combined to SWE measurements to grayscale US: 69.5–89.8% to 100.0%, while specificity was significantly improved: 62.5–81.7% to 13.9% (P < 0.001). Area under the ROC curve (A z ) did not show significant differences between grayscale US to US combined to SWE (P > 0.05). Conclusion: Pattern classification shows high correlation to maximum stiffness and may be representative of quantitative SWE values. When combined to grayscale US, SWE improves specificity of US

  9. Qualitative pattern classification of shear wave elastography for breast masses: How it correlates to quantitative measurements

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Jung Hyun, E-mail: lvjenny0417@gmail.com [Department of Radiology, CHA Bundang Medical Center, CHA University, School of Medicine (Korea, Republic of); Department of Radiology, Research Institute of Radiological Science, Yonsei University, College of Medicine (Korea, Republic of); Ko, Kyung Hee, E-mail: yourheeya@cha.ac.kr [Department of Radiology, CHA Bundang Medical Center, CHA University, School of Medicine (Korea, Republic of); Jung, Hae Kyoung, E-mail: AA40501@cha.ac.kr [Department of Radiology, CHA Bundang Medical Center, CHA University, School of Medicine (Korea, Republic of); Lee, Jong Tae, E-mail: jtlee@cha.ac.kr [Department of Radiology, CHA Bundang Medical Center, CHA University, School of Medicine (Korea, Republic of)

    2013-12-01

    Objective: To determine the correlation of qualitative shear wave elastography (SWE) pattern classification to quantitative SWE measurements and whether it is representative of quantitative SWE values with similar performances. Methods: From October 2012 to January 2013, 267 breast masses of 236 women (mean age: 45.12 ± 10.54 years, range: 21–88 years) who had undergone ultrasonography (US), SWE, and subsequent biopsy were included. US BI-RADS final assessment and qualitative and quantitative SWE measurements were recorded. Correlation between pattern classification and mean elasticity, maximum elasticity, elasticity ratio and standard deviation were evaluated. Diagnostic performances of grayscale US, SWE parameters, and US combined to SWE values were calculated and compared. Results: Of the 267 breast masses, 208 (77.9%) were benign and 59 (22.1%) were malignant. Pattern classifications significantly correlated with all quantitative SWE measurements, showing highest correlation with maximum elasticity, r = 0.721 (P < 0.001). Sensitivity was significantly decreased in US combined to SWE measurements to grayscale US: 69.5–89.8% to 100.0%, while specificity was significantly improved: 62.5–81.7% to 13.9% (P < 0.001). Area under the ROC curve (A{sub z}) did not show significant differences between grayscale US to US combined to SWE (P > 0.05). Conclusion: Pattern classification shows high correlation to maximum stiffness and may be representative of quantitative SWE values. When combined to grayscale US, SWE improves specificity of US.

  10. New possibilities in the prevention of eating disorders: The introduction of positive body image measures.

    Science.gov (United States)

    Piran, Niva

    2015-06-01

    Delineating positive psychological processes in inhabiting the body, as well as quantitative measures to assess them, can facilitate progress in the field of prevention of eating disorders by expanding outcome evaluation of prevention interventions, identifying novel mediators of change, and increasing highly needed research into protective factors. Moreover, enhancing positive ways of inhabiting the body may contribute toward the maintenance of gains of prevention interventions. Integrated social etiological models to eating disorders that focus on gender and other social variables, such as the Developmental Theory of Embodiment (Piran & Teall, 2012a), can contribute to positive body image intervention development and research within the prevention field. Using the Developmental Theory of Embodiment as a lens, this article explores whether existing prevention programs (i.e., Cognitive Dissonance and Media Smart) may already work to promote positive body image, and whether prevention programs need to be expanded toward this goal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  11. Quantitative angle-insensitive flow measurement using relative standard deviation OCT.

    Science.gov (United States)

    Zhu, Jiang; Zhang, Buyun; Qi, Li; Wang, Ling; Yang, Qiang; Zhu, Zhuqing; Huo, Tiancheng; Chen, Zhongping

    2017-10-30

    Incorporating different data processing methods, optical coherence tomography (OCT) has the ability for high-resolution angiography and quantitative flow velocity measurements. However, OCT angiography cannot provide quantitative information of flow velocities, and the velocity measurement based on Doppler OCT requires the determination of Doppler angles, which is a challenge in a complex vascular network. In this study, we report on a relative standard deviation OCT (RSD-OCT) method which provides both vascular network mapping and quantitative information for flow velocities within a wide range of Doppler angles. The RSD values are angle-insensitive within a wide range of angles, and a nearly linear relationship was found between the RSD values and the flow velocities. The RSD-OCT measurement in a rat cortex shows that it can quantify the blood flow velocities as well as map the vascular network in vivo .

  12. Quantitative chemical method for the determination of the disordered carbon component in pyrocarbon coatings of fuel particles

    International Nuclear Information System (INIS)

    Wolfrum, E.A.; Nickel, H.

    1977-01-01

    The chemical behavior of the surface of pyrocarbon (PyC) coatings of nuclear fuel particles was investigated in aqueous suspension by reaction with oxygen at room temperature. The concentration of the disordered material component, which has a large internal surface, can be identified by means of a pH change. Using this fact, a chemical method was developed that can be used for the quantitative determination of the concentration of this carbon component in the PyC coating

  13. Quantitative measurements of electromechanical response with a combined optical beam and interferometric atomic force microscope

    Energy Technology Data Exchange (ETDEWEB)

    Labuda, Aleksander; Proksch, Roger [Asylum Research an Oxford Instruments Company, Santa Barbara, California 93117 (United States)

    2015-06-22

    An ongoing challenge in atomic force microscope (AFM) experiments is the quantitative measurement of cantilever motion. The vast majority of AFMs use the optical beam deflection (OBD) method to infer the deflection of the cantilever. The OBD method is easy to implement, has impressive noise performance, and tends to be mechanically robust. However, it represents an indirect measurement of the cantilever displacement, since it is fundamentally an angular rather than a displacement measurement. Here, we demonstrate a metrological AFM that combines an OBD sensor with a laser Doppler vibrometer (LDV) to enable accurate measurements of the cantilever velocity and displacement. The OBD/LDV AFM allows a host of quantitative measurements to be performed, including in-situ measurements of cantilever oscillation modes in piezoresponse force microscopy. As an example application, we demonstrate how this instrument can be used for accurate quantification of piezoelectric sensitivity—a longstanding goal in the electromechanical community.

  14. A simple, semi-quantitative method for measuring pulsed soft x-rays

    International Nuclear Information System (INIS)

    Takahama, Y.; Du, J.; Yanagidaira, T.; Hirano, K.

    1993-01-01

    A simple semi-quantitative measurement and image processing system for pulsed soft X-rays with a time and spatial resolution is proposed. Performance of the system is examined using a cylindrical soft X-ray source generated with a plasma device. The system consists of commercial facilities which are easily obtained such as a microchannel plate-phosphor screen combination, a CCD camera, an image memory board and a personal computer. To make a quantitative measurement possible, the image processing and observation of the phosphor screen current are used in conjunction. (author)

  15. Smartphone data as objective measures of bipolar disorder symptoms

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Maria; Frost, Mads; Vinberg, Maj

    2014-01-01

    The daily electronic self-monitoring Smartphone software "MONARCA" was used by 17 patients with bipolar disorder for 3 consecutive months. Patients were rated fortnightly using Hamilton Depression rating Scale 17 items (HDRS-17) and Young Mania rating Scale (YMRS) (102 ratings) with blinding...... for Smartphone data. Objective Smartphone measures such as physical and social activity correlated with clinically rated depressive symptoms. Self-monitored depressive symptoms correlated significantly with HDRS-17 items score....

  16. Dual energy quantitative computed tomography (QCT). Precision of the mineral density measurements

    International Nuclear Information System (INIS)

    Braillon, P.; Bochu, M.

    1989-01-01

    The improvement that could be obtained in quantitative bone mineral measurements by dual energy computed tomography was tested in vitro. From the results of 15 mineral density measurements (in mg Ca/cm 3 , done on a precise lumbar spine phantom (Hologic) and referred to the values obtained on the same slices on a Siemens Osteo-CT phantom, the precision found was 0.8%, six times better than the precision calculated from the uncorrected measured values [fr

  17. New possibilities for quantitative measurements of regional cerebral blood flow with Au-195 m

    International Nuclear Information System (INIS)

    Lindner, P.; Nickel, O.

    1984-01-01

    A previously reported theory for quantitative cerebral blood flow measurement for nondiffusible radiotracers has been applied on patients after stroke and an volunteers undergoing a mental stimulation exercise. Quantitative measurements of cerebral blood flow patterns not only in p-a. but also in lateral views of the brain are possible by the use of the recently developed generator for the short lived (30 sec) isotope Au-195 m. The energy spectrum of the eluate of the generator shows two strong photon peaks, one at an energy level of 68 KeV and a second at an energy-level of 262 KeV. The low energy peak is suitable for perfusion studies in lateral views of the hemispheres, no ''look through'' effect is seen. The high energy level is good for studies in p-a-positions. The studies last less than 1 minute and can be repeated after 3 minutes. Parametric images for quantitative regional cerebral blood flow can be generated. The area of occluded vessels in the case of stroke can be detected. Quantitative activation patterns of cerebral blood flow during mental stimulation can be generated. The results prove that not only with freely diffusible indicators like Xenon but also with nondiffusible indicators it is possible to measure quantitatively cerebral blood flow patterns. (orig.)

  18. Qualitative pattern classification of shear wave elastography for breast masses: how it correlates to quantitative measurements.

    Science.gov (United States)

    Yoon, Jung Hyun; Ko, Kyung Hee; Jung, Hae Kyoung; Lee, Jong Tae

    2013-12-01

    To determine the correlation of qualitative shear wave elastography (SWE) pattern classification to quantitative SWE measurements and whether it is representative of quantitative SWE values with similar performances. From October 2012 to January 2013, 267 breast masses of 236 women (mean age: 45.12 ± 10.54 years, range: 21-88 years) who had undergone ultrasonography (US), SWE, and subsequent biopsy were included. US BI-RADS final assessment and qualitative and quantitative SWE measurements were recorded. Correlation between pattern classification and mean elasticity, maximum elasticity, elasticity ratio and standard deviation were evaluated. Diagnostic performances of grayscale US, SWE parameters, and US combined to SWE values were calculated and compared. Of the 267 breast masses, 208 (77.9%) were benign and 59 (22.1%) were malignant. Pattern classifications significantly correlated with all quantitative SWE measurements, showing highest correlation with maximum elasticity, r = 0.721 (P0.05). Pattern classification shows high correlation to maximum stiffness and may be representative of quantitative SWE values. When combined to grayscale US, SWE improves specificity of US. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Clusters of Insomnia Disorder: An Exploratory Cluster Analysis of Objective Sleep Parameters Reveals Differences in Neurocognitive Functioning, Quantitative EEG, and Heart Rate Variability

    Science.gov (United States)

    Miller, Christopher B.; Bartlett, Delwyn J.; Mullins, Anna E.; Dodds, Kirsty L.; Gordon, Christopher J.; Kyle, Simon D.; Kim, Jong Won; D'Rozario, Angela L.; Lee, Rico S.C.; Comas, Maria; Marshall, Nathaniel S.; Yee, Brendon J.; Espie, Colin A.; Grunstein, Ronald R.

    2016-01-01

    Study Objectives: To empirically derive and evaluate potential clusters of Insomnia Disorder through cluster analysis from polysomnography (PSG). We hypothesized that clusters would differ on neurocognitive performance, sleep-onset measures of quantitative (q)-EEG and heart rate variability (HRV). Methods: Research volunteers with Insomnia Disorder (DSM-5) completed a neurocognitive assessment and overnight PSG measures of total sleep time (TST), wake time after sleep onset (WASO), and sleep onset latency (SOL) were used to determine clusters. Results: From 96 volunteers with Insomnia Disorder, cluster analysis derived at least two clusters from objective sleep parameters: Insomnia with normal objective sleep duration (I-NSD: n = 53) and Insomnia with short sleep duration (I-SSD: n = 43). At sleep onset, differences in HRV between I-NSD and I-SSD clusters suggest attenuated parasympathetic activity in I-SSD (P insomnia clusters derived from cluster analysis differ in sleep onset HRV. Preliminary data suggest evidence for three clusters in insomnia with differences for sustained attention and sleep-onset q-EEG. Clinical Trial Registration: Insomnia 100 sleep study: Australia New Zealand Clinical Trials Registry (ANZCTR) identification number 12612000049875. URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=347742. Citation: Miller CB, Bartlett DJ, Mullins AE, Dodds KL, Gordon CJ, Kyle SD, Kim JW, D'Rozario AL, Lee RS, Comas M, Marshall NS, Yee BJ, Espie CA, Grunstein RR. Clusters of Insomnia Disorder: an exploratory cluster analysis of objective sleep parameters reveals differences in neurocognitive functioning, quantitative EEG, and heart rate variability. SLEEP 2016;39(11):1993–2004. PMID:27568796

  20. Quantitative measurement of cerebral blood flow on patients with early syphilis

    International Nuclear Information System (INIS)

    Zhong Jijun; Wu Jinchang; Yang Yi; Tang Jun; Liu Zengli; Shi Xin

    2005-01-01

    To study quantitative change of cerebral blood flow (CBF) on patients with early syphilis, the authors have established a method on absolute measurement of rCBF by using SPECT with Ethyl Cysteinate Dimmer (ECD) as imaging agent, and the method was applied to measure rCBF on patients with early syphilis. The rCBF values measured by this method are highly consistent with the values measured by other classical methods such as SPECT ( 123 I-IMP) and PET( 15 O-H 2 O). The rCBF values for early syphilis patients and the normal control show some statistical differences. A routine quantitative absolute measurement of rCBF featured with simple procedures is therefore on the way of maturation. (authors)

  1. A quantitative method to measure and evaluate the peelability of shrimps (Pandalus borealis)

    DEFF Research Database (Denmark)

    Gringer, Nina; Dang, Tem Thi; Orlien, Vibeke

    2018-01-01

    A novel, standardized method has been developed in order to provide a quantitative description of shrimp peelability. The peeling process was based on the measure of the strength of the shell-muscle attachment of the shrimp using a texture analyzer, and calculated into the peeling work. The self......-consistent method, insensitive of the shrimp size, was proven valid for assessment of ice maturation of shrimps. The quantitative peeling efficiency (peeling work) and performance (degree of shell removal) showed that the decrease in peeling work correlated with the amount of satisfactory peeled shrimps, indicating...... an effective weakening of the shell-muscle attachment. The developed method provides the industry with a quantitative analysis for measurement of peeling efficiency and peeling performance of shrimps. It may be used for comparing different maturation conditions in relation to optimization of shrimps peeling....

  2. The Reliability and Validity of the Panic Disorder Self-Report: A New Diagnostic Screening Measure of Panic Disorder

    Science.gov (United States)

    Newman, Michelle G.; Holmes, Marilyn; Zuellig, Andrea R.; Kachin, Kevin E.; Behar, Evelyn

    2006-01-01

    This study examined the Panic Disorder Self-Report (PDSR), a new self-report diagnostic measure of panic disorder based on the 4th edition of the Diagnostic and Statistical Manual of Mental Disorders (American Psychiatric Association, 1994). PDSR diagnoses were compared with structured interview diagnoses of individuals with generalized anxiety…

  3. Quantitative measurements and modeling of cargo–motor interactions during fast transport in the living axon

    International Nuclear Information System (INIS)

    Seamster, Pamela E; Loewenberg, Michael; Pascal, Jennifer; Chauviere, Arnaud; Gonzales, Aaron; Cristini, Vittorio; Bearer, Elaine L

    2012-01-01

    The kinesins have long been known to drive microtubule-based transport of sub-cellular components, yet the mechanisms of their attachment to cargo remain a mystery. Several different cargo-receptors have been proposed based on their in vitro binding affinities to kinesin-1. Only two of these—phosphatidyl inositol, a negatively charged lipid, and the carboxyl terminus of the amyloid precursor protein (APP-C), a trans-membrane protein—have been reported to mediate motility in living systems. A major question is how these many different cargo, receptors and motors interact to produce the complex choreography of vesicular transport within living cells. Here we describe an experimental assay that identifies cargo–motor receptors by their ability to recruit active motors and drive transport of exogenous cargo towards the synapse in living axons. Cargo is engineered by derivatizing the surface of polystyrene fluorescent nanospheres (100 nm diameter) with charged residues or with synthetic peptides derived from candidate motor receptor proteins, all designed to display a terminal COOH group. After injection into the squid giant axon, particle movements are imaged by laser-scanning confocal time-lapse microscopy. In this report we compare the motility of negatively charged beads with APP-C beads in the presence of glycine-conjugated non-motile beads using new strategies to measure bead movements. The ensuing quantitative analysis of time-lapse digital sequences reveals detailed information about bead movements: instantaneous and maximum velocities, run lengths, pause frequencies and pause durations. These measurements provide parameters for a mathematical model that predicts the spatiotemporal evolution of distribution of the two different types of bead cargo in the axon. The results reveal that negatively charged beads differ from APP-C beads in velocity and dispersion, and predict that at long time points APP-C will achieve greater progress towards the presynaptic

  4. Quantitative Reasoning in Environmental Science: Rasch Measurement to Support QR Assessment

    Directory of Open Access Journals (Sweden)

    Robert L. Mayes

    2015-07-01

    Full Text Available The ability of middle and high school students to reason quantitatively within the context of environmental science was investigated. A quantitative reasoning (QR learning progression, with associated QR assessments in the content areas of biodiversity, water, and carbon, was developed based on three QR progress variables: quantification act, quantitative interpretation, and quantitative modeling. Diagnostic instruments were developed specifically for the progress variable quantitative interpretation (QI, each consisting of 96 Likert-scale items. Each content version of the instrument focused on three scale levels (macro scale, micro scale, and landscape scale and four elements of QI identified in prior research (trend, translation, prediction, and revision. The QI assessments were completed by 362, 6th to 12th grade students in three U.S. states. Rasch (1960/1980 measurement was used to determine item and person measures for the QI instruments, both to examine validity and reliability characteristics of the instrument administration and inform the evolution of the learning progression. Rasch methods allowed identification of several QI instrument revisions, including modification of specific items, reducing number of items to avoid cognitive fatigue, reconsidering proposed item difficulty levels, and reducing Likert scale to 4 levels. Rasch diagnostics also indicated favorable levels of instrument reliability and appropriate targeting of item abilities to student abilities for the majority of participants. A revised QI instrument is available for STEM researchers and educators.

  5. Comprehensive Comparison of Self-Administered Questionnaires for Measuring Quantitative Autistic Traits in Adults

    Science.gov (United States)

    Nishiyama, Takeshi; Suzuki, Masako; Adachi, Katsunori; Sumi, Satoshi; Okada, Kensuke; Kishino, Hirohisa; Sakai, Saeko; Kamio, Yoko; Kojima, Masayo; Suzuki, Sadao; Kanne, Stephen M.

    2014-01-01

    We comprehensively compared all available questionnaires for measuring quantitative autistic traits (QATs) in terms of reliability and construct validity in 3,147 non-clinical and 60 clinical subjects with normal intelligence. We examined four full-length forms, the Subthreshold Autism Trait Questionnaire (SATQ), the Broader Autism Phenotype…

  6. The Reliability and Validity of Discrete and Continuous Measures of Psychopathology: A Quantitative Review

    Science.gov (United States)

    Markon, Kristian E.; Chmielewski, Michael; Miller, Christopher J.

    2011-01-01

    In 2 meta-analyses involving 58 studies and 59,575 participants, we quantitatively summarized the relative reliability and validity of continuous (i.e., dimensional) and discrete (i.e., categorical) measures of psychopathology. Overall, results suggest an expected 15% increase in reliability and 37% increase in validity through adoption of a…

  7. The predictive value of quantitative fibronectin testing in combination with cervical length measurement in symptomatic women

    NARCIS (Netherlands)

    Bruijn, Merel M. C.; Kamphuis, Esme I.; Hoesli, Irene M.; Martinez de Tejada, Begoña; Loccufier, Anne R.; Kühnert, Maritta; Helmer, Hanns; Franz, Marie; Porath, Martina M.; Oudijk, Martijn A.; Jacquemyn, Yves; Schulzke, Sven M.; Vetter, Grit; Hoste, Griet; Vis, Jolande Y.; Kok, Marjolein; Mol, Ben W. J.; van Baaren, Gert-Jan

    2016-01-01

    The combination of the qualitative fetal fibronectin test and cervical length measurement has a high negative predictive value for preterm birth within 7 days; however, positive prediction is poor. A new bedside quantitative fetal fibronectin test showed potential additional value over the

  8. Investigation of the genetic association between quantitative measures of psychosis and schizophrenia

    DEFF Research Database (Denmark)

    Derks, Eske M; Vorstman, Jacob A S; Ripke, Stephan

    2012-01-01

    The presence of subclinical levels of psychosis in the general population may imply that schizophrenia is the extreme expression of more or less continuously distributed traits in the population. In a previous study, we identified five quantitative measures of schizophrenia (positive, negative, d...

  9. Quantitative Measurement of Physical Activity in Acute Ischemic Stroke and Transient Ischemic Attack

    DEFF Research Database (Denmark)

    Strømmen, Anna Maria; Christensen, Thomas; Jensen, Kai

    2014-01-01

    BACKGROUND AND PURPOSE: The purpose of this study was to quantitatively measure and describe the amount and pattern of physical activity in patients within the first week after acute ischemic stroke and transient ischemic attack using accelerometers. METHODS: A total of 100 patients with acute is...

  10. Semi-quantitative myocardial perfusion measured by computed tomography in patients with refractory angina

    DEFF Research Database (Denmark)

    Qayyum, Abbas Ali; Kühl, Jørgen Tobias; Kjaer, Andreas

    2017-01-01

    INTRODUCTION: Computed tomography (CT) is a novel method for assessment of myocardial perfusion and has not yet been compared to rubidium-82 positron emission tomography (PET). We aimed to compare CT measured semi-quantitative myocardial perfusion with absolute quantified myocardial perfusion usi...

  11. Design of a Michelson Interferometer for Quantitative Refraction Index Profile Measurements

    NARCIS (Netherlands)

    Nijholt, J.L.M.

    1998-01-01

    This book describes the theoretical design of a three camera Michelson interferometer set-up for quantitative refractive index measuerments. Although a two camera system is easier to align and less expensive, a three camera interferometer is preferred because the expected measuring accuracy is much

  12. The usefulness of 3D quantitative analysis with using MRI for measuring osteonecrosis of the femoral head

    International Nuclear Information System (INIS)

    Hwang, Ji Young; Lee, Sun Wha; Park, Youn Soo

    2006-01-01

    We wanted to evaluate the usefulness of MRI 3D quantitative analysis for measuring osteonecrosis of the femoral head in comparison with MRI 2D quantitative analysis and quantitative analysis of the specimen. For 3 months at our hospital, 14 femoral head specimens with osteonecrosis were obtained after total hip arthroplasty. The patients preoperative MRIs were retrospectively reviewed for quantitative analysis of the size of the necrosis. Each necrotic fraction of the femoral head was measured by 2D quantitative analysis with using mid-coronal and mid-sagittal MRIs, and by 3D quantitative analysis with using serial continuous coronal MRIs and 3D reconstruction software. The necrotic fraction of the specimen was physically measured by the fluid displacement method. The necrotic fraction according to MRI 2D or 3D quantitative analysis was compared with that of the specimen by using Spearman's correlation test. On the correlative analysis, the necrotic fraction by MRI 2D quantitative analysis and quantitative analysis of the specimen showed moderate correlation (r = 0.657); on the other hand, the necrotic fraction by MRI 3D quantitative analysis and quantitative analysis of the specimen demonstrated a strong correlation (r = 0.952) (ρ < 0.05). MRI 3D quantitative analysis was more accurate than 2D quantitative analysis using MRI for measuring osteonecrosis of the femoral head. Therefore, it may be useful for predicting the clinical outcome and deciding the proper treatment option

  13. Quantitative mixture fraction measurements in combustion system via laser induced breakdown spectroscopy

    KAUST Repository

    Mansour, Mohy S.

    2015-01-01

    Laser induced breakdown spectroscopy (LIBS) technique has been applied to quantitative mixture fraction measurements in flames. The measured spectra of different mixtures of natural gas and air are used to obtain the calibration parameters for local elemental mass fraction measurements and hence calculate the mixture fraction. The results are compared with the mixture fraction calculations based on the ratios of the spectral lines of H/N elements, H/O elements and C/(N+O) and they show good agreement within the reaction zone of the flames. Some deviations are observed outside the reaction zone. The ability of LIBS technique as a tool for quantitative mixture fraction as well as elemental fraction measurements in reacting and non-reacting of turbulent flames is feasible. © 2014 Elsevier Ltd. All rights reserved.

  14. Portable instrumentation for quantitatively measuring radioactive surface contaminations, including 90Sr

    International Nuclear Information System (INIS)

    Brodzinski, R.L.

    1983-10-01

    In order to measure the effectiveness of decontamination efforts, a quantitative analysis of the radiocontamination is necessary, both before and after decontamination. Since it is desirable to release the decontaminated material for unrestricted use or disposal, the assay equipment must provide adequate sensitivity to measure the radioactivity at or below the release limit. In addition, the instrumentation must be capable of measuring all kinds of radiocontaminants including fission products, activation products, and transuranic materials. Finally, the survey instrumentation must be extremely versatile in order to assay the wide variety of contaminated surfaces in many environments, some of which may be extremely hostile or remote. This communication describes the development and application of portable instrumentation capable of quantitatively measuring most transuranics, activation products, and fission products, including 90 Sr, on almost any contaminated surface in nearly any location

  15. The importance of quantitative measurement methods for uveitis: laser flare photometry endorsed in Europe while neglected in Japan where the technology measuring quantitatively intraocular inflammation was developed.

    Science.gov (United States)

    Herbort, Carl P; Tugal-Tutkun, Ilknur

    2017-06-01

    Laser flare photometry (LFP) is an objective and quantitative method to measure intraocular inflammation. The LFP technology was developed in Japan and has been commercially available since 1990. The aim of this work was to review the application of LFP in uveitis practice in Europe compared to Japan where the technology was born. We reviewed PubMed articles published on LFP and uveitis. Although LFP has been largely integrated in routine uveitis practice in Europe, it has been comparatively neglected in Japan and still has not received FDA approval in the USA. As LFP is the only method that provides a precise measure of intraocular inflammation, it should be used as a gold standard in uveitis centres worldwide.

  16. Reineke’s stand density index: a quantitative and non-unitless measure of stand density

    Science.gov (United States)

    Curtis L. VanderSchaaf

    2013-01-01

    When used as a measure of relative density, Reineke’s stand density index (SDI) can be made unitless by relating the current SDI to a standard density but when used as a quantitative measure of stand density SDI is not unitless. Reineke’s SDI relates the current stand density to an equivalent number of trees per unit area in a stand with a quadratic mean diameter (Dq)...

  17. Quantitative analysis of disfluency in children with autism spectrum disorder or language impairment.

    Directory of Open Access Journals (Sweden)

    Heather MacFarlane

    Full Text Available Deficits in social communication, particularly pragmatic language, are characteristic of individuals with autism spectrum disorder (ASD. Speech disfluencies may serve pragmatic functions such as cueing speaking problems. Previous studies have found that speakers with ASD differ from typically developing (TD speakers in the types and patterns of disfluencies they produce, but fail to provide sufficiently detailed characterizations of the methods used to categorize and quantify disfluency, making cross-study comparison difficult. In this study we propose a simple schema for classifying major disfluency types, and use this schema in an exploratory analysis of differences in disfluency rates and patterns among children with ASD compared to TD and language impaired (SLI groups. 115 children ages 4-8 participated in the study (ASD = 51; SLI = 20; TD = 44, completing a battery of experimental tasks and assessments. Measures of morphological and syntactic complexity, as well as word and disfluency counts, were derived from transcripts of the Autism Diagnostic Observation Schedule (ADOS. High inter-annotator agreement was obtained with the use of the proposed schema. Analyses showed ASD children produced a higher ratio of content to filler disfluencies than TD children. Relative frequencies of repetitions, revisions, and false starts did not differ significantly between groups. TD children also produced more cued disfluencies than ASD children.

  18. Prediction of Coronal Mass Ejections from Vector Magnetograms: Quantitative Measures as Predictors

    Science.gov (United States)

    Falconer, D. A.; Moore, R. L.; Gary, G. A.

    2001-05-01

    In a pilot study of 4 active regions (Falconer, D.A. 2001, JGR, in press), we derived two quantitative measures of an active region's global nonpotentiality from the region's vector magnetogram, 1) the net current (IN), and 2) the length of the strong-shear, strong-field main neutral line (LSS), and used these two measures of the CME productivity of the active regions. We compared the global nonpotentiality measures to the active regions' CME productivity determined from GOES and Yohkoh/SXT observations. We found that two of the active regions were highly globally nonpotential and were CME productive, while the other two active regions had little global nonpotentiality and produced no CMEs. At the Fall 2000 AGU (Falconer, Moore, & Gary, 2000, EOS 81, 48 F998), we reported on an expanded study (12 active regions and 17 magnetograms) in which we evaluated four quantitative global measures of an active region's magnetic field and compared these measures with the CME productivity. The four global measures (all derived from MSFC vector magnetograms) included our two previous measures (IN and LSS) as well as two new ones, the total magnetic flux (Φ ) (a measure of an active region's size), and the normalized twist (α =μ IN/Φ ). We found that the three measures of global nonpotentiality (IN, LSS, α ) were all well correlated (>99% confidence level) with an active region's CME productivity within (2 days of the day of the magnetogram. We will now report on our findings of how good our quantitative measures are as predictors of active-region CME productivity, using only CMEs that occurred after the magnetogram. We report the preliminary skill test of these quantitative measures as predictors. We compare the CME prediction success of our quantitative measures to the CME prediction success based on an active region's past CME productivity. We examine the cases of the handful of false positive and false negatives to look for improvements to our predictors. This work is

  19. Longitudinal change in quantitative meniscus measurements in knee osteoarthritis - data from the Osteoarthritis Initiative

    International Nuclear Information System (INIS)

    Bloecker, Katja; Wirth, W.; Eckstein, F.; Guermazi, A.; Hitzl, W.; Hunter, D.J.

    2015-01-01

    We aimed to apply 3D MRI-based measurement technology to studying 2-year change in quantitative measurements of meniscus size and position. Forty-seven knees from the Osteoarthritis Initiative with medial radiographic joint space narrowing had baseline and 2-year follow-up MRIs. Quantitative measures were obtained from manual segmentation of the menisci and tibia using coronal DESSwe images. The standardized response mean (SRM = mean/SD change) was used as measure of sensitivity to longitudinal change. Medial tibial plateau coverage decreased from 34.8 % to 29.9 % (SRM -0.82; p < 0.001). Change in medial meniscus extrusion in a central image (SRM 0.18) and in the central five slices (SRM 0.22) did not reach significance, but change in extrusion across the entire meniscus (SRM 0.32; p = 0.03) and in the relative area of meniscus extrusion (SRM 0.56; p < 0.001) did. There was a reduction in medial meniscus volume (10 %; p < 0.001), width (7 %; p < 0.001), and height (2 %; p = 0.08); meniscus substance loss was strongest in the posterior (SRM -0.51; p = 0.001) and weakest in the anterior horn (SRM -0.15; p = 0.31). This pilot study reports, for the first time, longitudinal change in quantitative 3D meniscus measurements in knee osteoarthritis. It provides evidence of improved sensitivity to change of 3D measurements compared with single slice analysis. (orig.)

  20. Longitudinal change in quantitative meniscus measurements in knee osteoarthritis - data from the Osteoarthritis Initiative

    Energy Technology Data Exchange (ETDEWEB)

    Bloecker, Katja [Paracelsus Medical University Salzburg and Nuremberg (Austria); Salzburg, Institute of Anatomy, Salzburg (Austria); BHS Linz, Department of Orthopaedics, Linz (Austria); Wirth, W.; Eckstein, F. [Paracelsus Medical University Salzburg and Nuremberg (Austria); Salzburg, Institute of Anatomy, Salzburg (Austria); Chondrometrics GmbH, Ainring (Germany); Guermazi, A. [Boston University School of Medicine, Boston, MA (United States); Boston Imaging Core Lab (BICL), Boston, MA (United States); Hitzl, W. [Paracelsus Medical University Salzburg and Nuremberg, Research Office, Salzburg (Austria); Hunter, D.J. [University of Sydney, Royal North Shore Hospital and Institute of Bone and Joint Research, Kolling Institute, Sydney (Australia)

    2015-10-15

    We aimed to apply 3D MRI-based measurement technology to studying 2-year change in quantitative measurements of meniscus size and position. Forty-seven knees from the Osteoarthritis Initiative with medial radiographic joint space narrowing had baseline and 2-year follow-up MRIs. Quantitative measures were obtained from manual segmentation of the menisci and tibia using coronal DESSwe images. The standardized response mean (SRM = mean/SD change) was used as measure of sensitivity to longitudinal change. Medial tibial plateau coverage decreased from 34.8 % to 29.9 % (SRM -0.82; p < 0.001). Change in medial meniscus extrusion in a central image (SRM 0.18) and in the central five slices (SRM 0.22) did not reach significance, but change in extrusion across the entire meniscus (SRM 0.32; p = 0.03) and in the relative area of meniscus extrusion (SRM 0.56; p < 0.001) did. There was a reduction in medial meniscus volume (10 %; p < 0.001), width (7 %; p < 0.001), and height (2 %; p = 0.08); meniscus substance loss was strongest in the posterior (SRM -0.51; p = 0.001) and weakest in the anterior horn (SRM -0.15; p = 0.31). This pilot study reports, for the first time, longitudinal change in quantitative 3D meniscus measurements in knee osteoarthritis. It provides evidence of improved sensitivity to change of 3D measurements compared with single slice analysis. (orig.)

  1. Effect of Voltage Measurement on the Quantitative Identification of Transverse Cracks by Electrical Measurements

    KAUST Repository

    Selvakumaran, Lakshmi; Lubineau, Gilles

    2016-01-01

    of the ply. Through the mesoscale relationship, the conductivity obtained from electrical tomography can be used as a measure of the transverse cracking density. Interpretation of this measure will be accurate provided the assumptions made during

  2. Multi-class parkinsonian disorders classification with quantitative MR markers and graph-based features using support vector machines.

    Science.gov (United States)

    Morisi, Rita; Manners, David Neil; Gnecco, Giorgio; Lanconelli, Nico; Testa, Claudia; Evangelisti, Stefania; Talozzi, Lia; Gramegna, Laura Ludovica; Bianchini, Claudio; Calandra-Buonaura, Giovanna; Sambati, Luisa; Giannini, Giulia; Cortelli, Pietro; Tonon, Caterina; Lodi, Raffaele

    2018-02-01

    In this study we attempt to automatically classify individual patients with different parkinsonian disorders, making use of pattern recognition techniques to distinguish among several forms of parkinsonisms (multi-class classification), based on a set of binary classifiers that discriminate each disorder from all others. We combine diffusion tensor imaging, proton spectroscopy and morphometric-volumetric data to obtain MR quantitative markers, which are provided to support vector machines with the aim of recognizing the different parkinsonian disorders. Feature selection is used to find the most important features for classification. We also exploit a graph-based technique on the set of quantitative markers to extract additional features from the dataset, and increase classification accuracy. When graph-based features are not used, the MR markers that are most frequently automatically extracted by the feature selection procedure reflect alterations in brain regions that are also usually considered to discriminate parkinsonisms in routine clinical practice. Graph-derived features typically increase the diagnostic accuracy, and reduce the number of features required. The results obtained in the work demonstrate that support vector machines applied to multimodal brain MR imaging and using graph-based features represent a novel and highly accurate approach to discriminate parkinsonisms, and a useful tool to assist the diagnosis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Quantitative shearography: error reduction by using more than three measurement channels

    International Nuclear Information System (INIS)

    Charrett, Tom O. H.; Francis, Daniel; Tatam, Ralph P.

    2011-01-01

    Shearography is a noncontact optical technique used to measure surface displacement derivatives. Full surface strain characterization can be achieved using shearography configurations employing at least three measurement channels. Each measurement channel is sensitive to a single displacement gradient component defined by its sensitivity vector. A matrix transformation is then required to convert the measured components to the orthogonal displacement gradients required for quantitative strain measurement. This transformation, conventionally performed using three measurement channels, amplifies any errors present in the measurement. This paper investigates the use of additional measurement channels using the results of a computer model and an experimental shearography system. Results are presented showing that the addition of a fourth channel can reduce the errors in the computed orthogonal components by up to 33% and that, by using 10 channels, reductions of around 45% should be possible.

  4. Quantitative liquid and vapor distribution measurements in evaporating fuel sprays using laser-induced exciplex fluorescence

    International Nuclear Information System (INIS)

    Fansler, Todd D; Drake, Michael C; Gajdeczko, Boguslaw; Düwel, Isabell; Koban, Wieland; Zimmermann, Frank P; Schulz, Christof

    2009-01-01

    Fully quantitative two-dimensional measurements of liquid- and vapor-phase fuel distributions (mass per unit volume) from high-pressure direct-injection gasoline injectors are reported for conditions of both slow and rapid vaporization in a heated, high-pressure spray chamber. The measurements employ the coevaporative gasoline-like fluorobenzene (FB)/diethylmethylamine (DEMA)/hexane exciplex tracer/fuel system. In contrast to most previous laser-induced exciplex-fluorescence (LIEF) experiments, the quantitative results here include regions in which liquid and vapor fuel coexist (e.g. near the injector exit). A unique aspect is evaluation of both vapor- and liquid-phase distributions at varying temperature and pressure using only in situ vapor-phase fluorescence calibration measurements at room temperature and atmospheric pressure. This approach draws on recent extensive measurements of the temperature-dependent spectroscopic properties of the FB–DEMA exciplex system, in particular on knowledge of the quantum efficiencies of the vapor-phase and liquid-phase (exciplex) fluorescence. In addition to procedures necessary for quantitative measurements, we discuss corrections for liquid–vapor crosstalk (liquid fluorescence that overlaps the vapor-fluorescence bandpass), the unknown local temperature due to vaporization-induced cooling, and laser-sheet attenuation by scattering and absorption

  5. Clusters of Insomnia Disorder: An Exploratory Cluster Analysis of Objective Sleep Parameters Reveals Differences in Neurocognitive Functioning, Quantitative EEG, and Heart Rate Variability.

    Science.gov (United States)

    Miller, Christopher B; Bartlett, Delwyn J; Mullins, Anna E; Dodds, Kirsty L; Gordon, Christopher J; Kyle, Simon D; Kim, Jong Won; D'Rozario, Angela L; Lee, Rico S C; Comas, Maria; Marshall, Nathaniel S; Yee, Brendon J; Espie, Colin A; Grunstein, Ronald R

    2016-11-01

    To empirically derive and evaluate potential clusters of Insomnia Disorder through cluster analysis from polysomnography (PSG). We hypothesized that clusters would differ on neurocognitive performance, sleep-onset measures of quantitative ( q )-EEG and heart rate variability (HRV). Research volunteers with Insomnia Disorder (DSM-5) completed a neurocognitive assessment and overnight PSG measures of total sleep time (TST), wake time after sleep onset (WASO), and sleep onset latency (SOL) were used to determine clusters. From 96 volunteers with Insomnia Disorder, cluster analysis derived at least two clusters from objective sleep parameters: Insomnia with normal objective sleep duration (I-NSD: n = 53) and Insomnia with short sleep duration (I-SSD: n = 43). At sleep onset, differences in HRV between I-NSD and I-SSD clusters suggest attenuated parasympathetic activity in I-SSD (P insomnia clusters derived from cluster analysis differ in sleep onset HRV. Preliminary data suggest evidence for three clusters in insomnia with differences for sustained attention and sleep-onset q -EEG. Insomnia 100 sleep study: Australia New Zealand Clinical Trials Registry (ANZCTR) identification number 12612000049875. URL: https://www.anzctr.org.au/Trial/Registration/TrialReview.aspx?id=347742. © 2016 Associated Professional Sleep Societies, LLC.

  6. A Systematic Review of Quantitative Resilience Measures for Water Infrastructure Systems

    Directory of Open Access Journals (Sweden)

    Sangmin Shin

    2018-02-01

    Full Text Available Over the past few decades, the concept of resilience has emerged as an important consideration in the planning and management of water infrastructure systems. Accordingly, various resilience measures have been developed for the quantitative evaluation and decision-making of systems. There are, however, numerous considerations and no clear choice of which measure, if any, provides the most appropriate representation of resilience for a given application. This study provides a critical review of quantitative approaches to measure the resilience of water infrastructure systems, with a focus on water resources and distribution systems. A compilation of 11 criteria evaluating 21 selected resilience measures addressing major features of resilience is developed using the Axiomatic Design process. Existing gaps of resilience measures are identified based on the review criteria. The results show that resilience measures have generally paid less attention to cascading damage to interrelated systems, rapid identification of failure, physical damage of system components, and time variation of resilience. Concluding the paper, improvements to resilience measures are recommended. The findings contribute to our understanding of gaps and provide information to help further improve resilience measures of water infrastructure systems.

  7. High temperature and high pressure gas cell for quantitative spectroscopic measurements

    DEFF Research Database (Denmark)

    Christiansen, Caspar; Stolberg-Rohr, Thomine; Fateev, Alexander

    2016-01-01

    A high temperature and high pressure gas cell (HTPGC) has been manufactured for quantitative spectroscopic measurements in the pressure range 1-200 bar and temperature range 300-1300 K. In the present work the cell was employed at up to 100 bar and 1000 K, and measured absorption coefficients...... of a CO2-N2 mixture at 100 bar and 1000 K are revealed for the first time, exceeding the high temperature and pressure combinations previously reported. This paper discusses the design considerations involved in the construction of the cell and presents validation measurements compared against simulated...

  8. Navigational Traffic Conflict Technique: A Proactive Approach to Quantitative Measurement of Collision Risks in Port Waters

    Science.gov (United States)

    Debnath, Ashim Kumar; Chin, Hoong Chor

    Navigational safety analysis relying on collision statistics is often hampered because of the low number of observations. A promising alternative approach that overcomes this problem is proposed in this paper. By analyzing critical vessel interactions this approach proactively measures collision risk in port waters. The proposed method is illustrated for quantitative measurement of collision risks in Singapore port fairways, and validated by examining correlations between the measured risks with those perceived by pilots. This method is an ethically appealing alternative to the collision-based analysis for fast, reliable and effective safety assessment, thus possessing great potential for managing collision risks in port waters.

  9. A magneto-optical microscope for quantitative measurement of magnetic microstructures.

    Science.gov (United States)

    Patterson, W C; Garraud, N; Shorman, E E; Arnold, D P

    2015-09-01

    An optical system is presented to quantitatively map the stray magnetic fields of microscale magnetic structures, with field resolution down to 50 μT and spatial resolution down to 4 μm. The system uses a magneto-optical indicator film (MOIF) in conjunction with an upright reflective polarizing light microscope to generate optical images of the magnetic field perpendicular to the image plane. A novel single light path construction and discrete multi-image polarimetry processing method are used to extract quantitative areal field measurements from the optical images. The integrated system including the equipment, image analysis software, and experimental methods are described. MOIFs with three different magnetic field ranges are calibrated, and the entire system is validated by measurement of the field patterns from two calibration samples.

  10. Quantitative measurement of solvation shells using frequency modulated atomic force microscopy

    Science.gov (United States)

    Uchihashi, T.; Higgins, M.; Nakayama, Y.; Sader, J. E.; Jarvis, S. P.

    2005-03-01

    The nanoscale specificity of interaction measurements and additional imaging capability of the atomic force microscope make it an ideal technique for measuring solvation shells in a variety of liquids next to a range of materials. Unfortunately, the widespread use of atomic force microscopy for the measurement of solvation shells has been limited by uncertainties over the dimensions, composition and durability of the tip during the measurements, and problems associated with quantitative force calibration of the most sensitive dynamic measurement techniques. We address both these issues by the combined use of carbon nanotube high aspect ratio probes and quantifying the highly sensitive frequency modulation (FM) detection technique using a recently developed analytical method. Due to the excellent reproducibility of the measurement technique, additional information regarding solvation shell size as a function of proximity to the surface has been obtained for two very different liquids. Further, it has been possible to identify differences between chemical and geometrical effects in the chosen systems.

  11. Effect of Voltage Measurement on the Quantitative Identification of Transverse Cracks by Electrical Measurements

    KAUST Repository

    Selvakumaran, Lakshmi

    2016-03-24

    Electrical tomography can be used as a structural health monitoring technique to identify different damage mechanisms in composite laminates. Previous work has established the link between transverse cracking density and mesoscale conductivity of the ply. Through the mesoscale relationship, the conductivity obtained from electrical tomography can be used as a measure of the transverse cracking density. Interpretation of this measure will be accurate provided the assumptions made during homogenization are valid. One main assumption of mesoscale homogenization is that the electric field is in the plane. Here, we test the validity of this assumption for laminates with varying anisotropy ratios and for different distances between the cracked ply and surface that is instrumented with electrodes. We also show the equivalence in electrical response between measurements from cracked laminates and their equivalent mesoscale counterparts. Finally, we propose some general guidelines on the measurement strategy for maximizing the accuracy of transverse cracks identification.

  12. A Major Locus for Quantitatively Measured Shank Skin Color Traits in Korean Native Chicken

    Directory of Open Access Journals (Sweden)

    S. Jin

    2016-11-01

    Full Text Available Shank skin color of Korean native chicken (KNC shows large color variations. It varies from white, yellow, green, bluish or grey to black, whilst in the majority of European breeds the shanks are typically yellow-colored. Three shank skin color-related traits (i.e., lightness [L*], redness [a*], and yellowness [b*] were measured by a spectrophotometer in 585 progeny from 68 nuclear families in the KNC resource population. We performed genome scan linkage analysis to identify loci that affect quantitatively measured shank skin color traits in KNC. All these birds were genotyped with 167 DNA markers located throughout the 26 autosomes. The SOLAR program was used to conduct multipoint variance-component quantitative trait locus (QTL analyses. We detected a major QTL that affects b* value (logarithm of odds [LOD] = 47.5, p = 1.60×10−49 on GGA24 (GGA for Gallus gallus. At the same location, we also detected a QTL that influences a* value (LOD = 14.2, p = 6.14×10−16. Additionally, beta-carotene dioxygenase 2 (BCDO2, the obvious positional candidate gene under the linkage peaks on GGA24, was investigated by the two association tests: i.e., measured genotype association (MGA and quantitative transmission disequilibrium test (QTDT. Significant associations were detected between BCDO2 g.9367 A>C and a* (PMGA = 1.69×10−28; PQTDT = 2.40×10−25. The strongest associations were between BCDO2 g.9367 A>C and b* (PMGA = 3.56×10−66; PQTDT = 1.68×10−65. However, linkage analyses conditional on the single nucleotide polymorphism indicated that other functional variants should exist. Taken together, we demonstrate for the first time the linkage and association between the BCDO2 locus on GGA24 and quantitatively measured shank skin color traits in KNC.

  13. Resting quantitative cerebral blood flow in schizophrenia measured by pulsed arterial spin labeling perfusion MRI

    OpenAIRE

    Pinkham, Amy; Loughead, James; Ruparel, Kosha; Wu, Wen-Chau; Overton, Eve; Gur, Raquel; Gur, Ruben

    2011-01-01

    Arterial spin labeling imaging (ASL) perfusion MRI is a relatively novel technique that can allow for quantitative measurement of cerebral blood flow (CBF) by using magnetically labeled arterial blood water as an endogenous tracer. Available data on resting CBF in schizophrenia primarily comes from invasive and expensive nuclear medicine techniques that are often limited to small samples and yield mixed results. The noninvasive nature of ASL offers promise for larger-scale studies. The utilit...

  14. Quantitative analysis of lattice disorder and crystallite size in organic semiconductor thin films

    KAUST Repository

    Rivnay, Jonathan

    2011-07-07

    The crystallite size and cumulative lattice disorder of three prototypical, high-performing organic semiconducting materials are investigated using a Fourier-transform peak shape analysis routine based on the method of Warren and Averbach (WA). A thorough incorporation of error propagation throughout the multistep analysis and a weighted fitting of Fourier-transformed data to the WA model allows for more accurate results than typically obtained and for determination of confidence bounds. We compare results obtained when assuming two types of column-length distributions, and discuss the benefits of each model in terms of simplicity and accuracy. For strongly disordered materials, the determination of a crystallite size is greatly hindered because disorder dominates the coherence length, not finite size. A simple analysis based on trends of peak widths and Lorentzian components of pseudo-Voigt line shapes as a function of diffraction order is also discussed as an approach to more easily and qualitatively assess the amount and type of disorder present in a sample. While applied directly to organic systems, this methodology is general for the accurate deconvolution of crystalline size and lattice disorder for any material investigated with diffraction techniques. © 2011 American Physical Society.

  15. Actigraph measures discriminate pediatric bipolar disorder from attention-deficit/hyperactivity disorder and typically developing controls.

    Science.gov (United States)

    Faedda, Gianni L; Ohashi, Kyoko; Hernandez, Mariely; McGreenery, Cynthia E; Grant, Marie C; Baroni, Argelinda; Polcari, Ann; Teicher, Martin H

    2016-06-01

    Distinguishing pediatric bipolar disorder (BD) from attention-deficit hyperactivity disorder (ADHD) can be challenging. Hyperactivity is a core feature of both disorders, but severely disturbed sleep and circadian dysregulation are more characteristic of BD, at least in adults. We tested the hypothesis that objective measures of activity, sleep, and circadian rhythms would help differentiate pediatric subjects with BD from ADHD and typically developing controls. Unmedicated youths (N = 155, 97 males, age 5-18) were diagnosed using DSM-IV criteria with Kiddie-SADS PL/E. BD youths (n = 48) were compared to typically developing controls (n = 42) and children with ADHD (n = 44) or ADHD plus comorbid depressive disorders (n = 21). Three-to-five days of minute-to-minute belt-worn actigraph data (Ambulatory Monitoring Inc.), collected during the school week, were processed to yield 28 metrics per subject, and assessed for group differences with analysis of covariance. Cross-validated machine learning algorithms were used to determine the predictive accuracy of a four-parameter model, with measures reflecting sleep, hyperactivity, and circadian dysregulation, plus Indic's bipolar vulnerability index (VI). There were prominent group differences in several activity measures, notably mean 5 lowest hours of activity, skewness of diurnal activity, relative circadian amplitude, and VI. A predictive support vector machine model discriminated bipolar from non-bipolar with mean accuracy of 83.1 ± 5.4%, ROC area of 0.781 ± 0.071, kappa of 0.587 ± 0.136, specificity of 91.7 ± 5.3%, and sensitivity of 64.4 ± 13.6%. Objective measures of sleep, circadian rhythmicity, and hyperactivity were abnormal in BD. Wearable sensor technology may provide bio-behavioral markers that can help differentiate children with BD from ADHD and healthy controls. © 2016 Association for Child and Adolescent Mental Health.

  16. Sieve-based device for MALDI sample preparation. III. Its power for quantitative measurements.

    Science.gov (United States)

    Molin, Laura; Cristoni, Simone; Seraglia, Roberta; Traldi, Pietro

    2011-02-01

    The solid sample inhomogeneity is a weak point of traditional MALDI deposition techniques that reflects negatively on quantitative analysis. The recently developed sieve-based device (SBD) sample deposition method, based on the electrospraying of matrix/analyte solutions through a grounded sieve, allows the homogeneous deposition of microcrystals with dimensions smaller than that of the laser spot. In each microcrystal the matrix/analyte molar ratio can be considered constant. Then, by irradiating different portions of the microcrystal distribution an identical response is obtained. This result suggests the employment of SBD in the development of quantitative procedures. For this aim, mixtures of different proteins of known molarity were analyzed, showing a good relationship between molarity and intensity ratios. This behaviour was also observed in the case of proteins with quite different ionic yields. The power of the developed method for quantitative evaluation was also tested by the measurement of the abundance of IGPP[Oxi]GPP[Oxi]GLMGPP (m/z 1219) present in the collagen-α-5(IV) chain precursor, differently expressed in urines from healthy subjects and diabetic-nephropathic patients, confirming its overexpression in the presence of nephropathy. The data obtained indicate that SBD is a particularly effective method for quantitative analysis also in biological fluids of interest. Copyright © 2011 John Wiley & Sons, Ltd.

  17. Sex differences in objective measures of sleep in post-traumatic stress disorder and healthy control subjects.

    Science.gov (United States)

    Richards, Anne; Metzler, Thomas J; Ruoff, Leslie M; Inslicht, Sabra S; Rao, Madhu; Talbot, Lisa S; Neylan, Thomas C

    2013-12-01

    A growing literature shows prominent sex effects for risk for post-traumatic stress disorder and associated medical comorbid burden. Previous research indicates that post-traumatic stress disorder is associated with reduced slow wave sleep, which may have implications for overall health, and abnormalities in rapid eye movement sleep, which have been implicated in specific post-traumatic stress disorder symptoms, but most research has been conducted in male subjects. We therefore sought to compare objective measures of sleep in male and female post-traumatic stress disorder subjects with age- and sex-matched control subjects. We used a cross-sectional, 2 × 2 design (post-traumatic stress disorder/control × female/male) involving83 medically healthy, non-medicated adults aged 19-39 years in the inpatient sleep laboratory. Visual electroencephalographic analysis demonstrated that post-traumatic stress disorder was associated with lower slow wave sleep duration (F(3,82)  = 7.63, P = 0.007) and slow wave sleep percentage (F(3,82)  = 6.11, P = 0.016). There was also a group × sex interaction effect for rapid eye movement sleep duration (F(3,82)  = 4.08, P = 0.047) and rapid eye movement sleep percentage (F(3,82)  = 4.30, P = 0.041), explained by greater rapid eye movement sleep in post-traumatic stress disorder females compared to control females, a difference not seen in male subjects. Quantitative electroencephalography analysis demonstrated that post-traumatic stress disorder was associated with lower energy in the delta spectrum (F(3,82)  = 6.79, P = 0.011) in non-rapid eye movement sleep. Slow wave sleep and delta findings were more pronounced in males. Removal of post-traumatic stress disorder subjects with comorbid major depressive disorder, who had greater post-traumatic stress disorder severity, strengthened delta effects but reduced rapid eye movement effects to non-significance. These findings support previous evidence that post

  18. Standardized Approach to Quantitatively Measure Residual Limb Skin Health in Individuals with Lower Limb Amputation.

    Science.gov (United States)

    Rink, Cameron L; Wernke, Matthew M; Powell, Heather M; Tornero, Mark; Gnyawali, Surya C; Schroeder, Ryan M; Kim, Jayne Y; Denune, Jeffrey A; Albury, Alexander W; Gordillo, Gayle M; Colvin, James M; Sen, Chandan K

    2017-07-01

    Objective: (1) Develop a standardized approach to quantitatively measure residual limb skin health. (2) Report reference residual limb skin health values in people with transtibial and transfemoral amputation. Approach: Residual limb health outcomes in individuals with transtibial ( n  = 5) and transfemoral ( n  = 5) amputation were compared to able-limb controls ( n  = 4) using noninvasive imaging (hyperspectral imaging and laser speckle flowmetry) and probe-based approaches (laser doppler flowmetry, transcutaneous oxygen, transepidermal water loss, surface electrical capacitance). Results: A standardized methodology that employs noninvasive imaging and probe-based approaches to measure residual limb skin health are described. Compared to able-limb controls, individuals with transtibial and transfemoral amputation have significantly lower transcutaneous oxygen tension, higher transepidermal water loss, and higher surface electrical capacitance in the residual limb. Innovation: Residual limb health as a critical component of prosthesis rehabilitation for individuals with lower limb amputation is understudied in part due to a lack of clinical measures. Here, we present a standardized approach to measure residual limb health in people with transtibial and transfemoral amputation. Conclusion: Technology advances in noninvasive imaging and probe-based measures are leveraged to develop a standardized approach to quantitatively measure residual limb health in individuals with lower limb loss. Compared to able-limb controls, resting residual limb physiology in people that have had transfemoral or transtibial amputation is characterized by lower transcutaneous oxygen tension and poorer skin barrier function.

  19. Quantitative stress measurement of elastic deformation using mechanoluminescent sensor: An intensity ratio model

    Science.gov (United States)

    Cai, Tao; Guo, Songtao; Li, Yongzeng; Peng, Di; Zhao, Xiaofeng; Liu, Yingzheng

    2018-04-01

    The mechanoluminescent (ML) sensor is a newly developed non-invasive technique for stress/strain measurement. However, its application has been mostly restricted to qualitative measurement due to the lack of a well-defined relationship between ML intensity and stress. To achieve accurate stress measurement, an intensity ratio model was proposed in this study to establish a quantitative relationship between the stress condition and its ML intensity in elastic deformation. To verify the proposed model, experiments were carried out on a ML measurement system using resin samples mixed with the sensor material SrAl2O4:Eu2+, Dy3+. The ML intensity ratio was found to be dependent on the applied stress and strain rate, and the relationship acquired from the experimental results agreed well with the proposed model. The current study provided a physical explanation for the relationship between ML intensity and its stress condition. The proposed model was applicable in various SrAl2O4:Eu2+, Dy3+-based ML measurement in elastic deformation, and could provide a useful reference for quantitative stress measurement using the ML sensor in general.

  20. Quantitative And Qualitative Measurement Of Radio- Activity In Sand Samples From Chalet Beach In Songkhla Province

    International Nuclear Information System (INIS)

    Sukhowattanakit, Jirapa; Kessaratikoon, Prasong; Udomsomporn, Suchin; Thorarit, Wutthidej

    2005-10-01

    The quantitative and qualitative measurement of radioactivity in 39 sand samples collected from Chalatat beach in Songkhla province are presented. Experimental results were obtained by using a high-purity germanium detector and gamma spectroscopy analysis system and comparing to the standard soil (IAEA SOIL 6) at the Office of Atoms for Peace (OAP). The measuring time of all sand samples is 10,000 seconds. Some radioisotopes such as K-40, Cs-137, Tl-208, Bi-212, Pb-212, Bi-214, Pb- 214, Ra-226 and Ac-228 were found in sand samples. In addition, the radioactivity of Ra-226 and Cs-137 in those samples were found in normal level

  1. Quantitative density measurements from a real-time neutron radiography system

    International Nuclear Information System (INIS)

    McRae, D.D.; Jenkins, R.W. Jr.; Brenizer, J.S.; Tobin, K.W.; Hosticka, B.; Sulcoski, M.F.

    1986-01-01

    An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation

  2. Quantitative measurement of piezoelectric coefficient of thin film using a scanning evanescent microwave microscope.

    Science.gov (United States)

    Zhao, Zhenli; Luo, Zhenlin; Liu, Chihui; Wu, Wenbin; Gao, Chen; Lu, Yalin

    2008-06-01

    This article describes a new approach to quantitatively measure the piezoelectric coefficients of thin films at the microscopic level using a scanning evanescent microwave microscope. This technique can resolve 10 pm deformation caused by the piezoelectric effect and has the advantages of high scanning speed, large scanning area, submicron spatial resolution, and a simultaneous accessibility to many other related properties. Results from the test measurements on the longitudinal piezoelectric coefficient of PZT thin film agree well with those from other techniques listed in literatures.

  3. A specialized plug-in software module for computer-aided quantitative measurement of medical images.

    Science.gov (United States)

    Wang, Q; Zeng, Y J; Huo, P; Hu, J L; Zhang, J H

    2003-12-01

    This paper presents a specialized system for quantitative measurement of medical images. Using Visual C++, we developed a computer-aided software based on Image-Pro Plus (IPP), a software development platform. When transferred to the hard disk of a computer by an MVPCI-V3A frame grabber, medical images can be automatically processed by our own IPP plug-in for immunohistochemical analysis, cytomorphological measurement and blood vessel segmentation. In 34 clinical studies, the system has shown its high stability, reliability and ease of utility.

  4. A novel scale for measuring mixed states in bipolar disorder.

    Science.gov (United States)

    Cavanagh, Jonathan; Schwannauer, Matthias; Power, Mick; Goodwin, Guy M

    2009-01-01

    Conventional descriptions of bipolar disorder tend to treat the mixed state as something of an afterthought. There is no scale that specifically measures the phenomena of the mixed state. This study aimed to test a novel scale for mixed state in a clinical and community population of bipolar patients. The scale included clinically relevant symptoms of both mania and depression in a bivariate scale. Recovered respondents were asked to recall their last manic episode. The scale allowed endorsement of one or more of the manic and depressive symptoms. Internal consistency analyses were carried out using Cronbach alpha. Factor analysis was carried out using a standard Principal Components Analysis followed by Varimax Rotation. A confirmatory factor analytic method was used to validate the scale structure in a representative clinical sample. The reliability analysis gave a Cronbach alpha value of 0.950, with a range of corrected-item-total-scale correlations from 0.546 (weight change) to 0.830 (mood). The factor analysis revealed a two-factor solution for the manic and depressed items which accounted for 61.2% of the variance in the data. Factor 1 represented physical activity, verbal activity, thought processes and mood. Factor 2 represented eating habits, weight change, passage of time and pain sensitivity. This novel scale appears to capture the key features of mixed states. The two-factor solution fits well with previous models of bipolar disorder and concurs with the view that mixed states may be more than the sum of their parts.

  5. Practicable methods for histological section thickness measurement in quantitative stereological analyses.

    Science.gov (United States)

    Matenaers, Cyrill; Popper, Bastian; Rieger, Alexandra; Wanke, Rüdiger; Blutke, Andreas

    2018-01-01

    The accuracy of quantitative stereological analysis tools such as the (physical) disector method substantially depends on the precise determination of the thickness of the analyzed histological sections. One conventional method for measurement of histological section thickness is to re-embed the section of interest vertically to its original section plane. The section thickness is then measured in a subsequently prepared histological section of this orthogonally re-embedded sample. However, the orthogonal re-embedding (ORE) technique is quite work- and time-intensive and may produce inaccurate section thickness measurement values due to unintentional slightly oblique (non-orthogonal) positioning of the re-embedded sample-section. Here, an improved ORE method is presented, allowing for determination of the factual section plane angle of the re-embedded section, and correction of measured section thickness values for oblique (non-orthogonal) sectioning. For this, the analyzed section is mounted flat on a foil of known thickness (calibration foil) and both the section and the calibration foil are then vertically (re-)embedded. The section angle of the re-embedded section is then calculated from the deviation of the measured section thickness of the calibration foil and its factual thickness, using basic geometry. To find a practicable, fast, and accurate alternative to ORE, the suitability of spectral reflectance (SR) measurement for determination of plastic section thicknesses was evaluated. Using a commercially available optical reflectometer (F20, Filmetrics®, USA), the thicknesses of 0.5 μm thick semi-thin Epon (glycid ether)-sections and of 1-3 μm thick plastic sections (glycolmethacrylate/ methylmethacrylate, GMA/MMA), as regularly used in physical disector analyses, could precisely be measured within few seconds. Compared to the measured section thicknesses determined by ORE, SR measures displayed less than 1% deviation. Our results prove the applicability

  6. Ab initio structure determination and quantitative disorder analysis on nanoparticles by electron diffraction tomography.

    Science.gov (United States)

    Krysiak, Yaşar; Barton, Bastian; Marler, Bernd; Neder, Reinhard B; Kolb, Ute

    2018-03-01

    Nanoscaled porous materials such as zeolites have attracted substantial attention in industry due to their catalytic activity, and their performance in sorption and separation processes. In order to understand the properties of such materials, current research focuses increasingly on the determination of structural features beyond the averaged crystal structure. Small particle sizes, various types of disorder and intergrown structures render the description of structures at atomic level by standard crystallographic methods difficult. This paper reports the characterization of a strongly disordered zeolite structure, using a combination of electron exit-wave reconstruction, automated diffraction tomography (ADT), crystal disorder modelling and electron diffraction simulations. Zeolite beta was chosen for a proof-of-principle study of the techniques, because it consists of two different intergrown polymorphs that are built from identical layer types but with different stacking sequences. Imaging of the projected inner Coulomb potential of zeolite beta crystals shows the intergrowth of the polymorphs BEA and BEB. The structures of BEA as well as BEB could be extracted from one single ADT data set using direct methods. A ratio for BEA/BEB = 48:52 was determined by comparison of the reconstructed reciprocal space based on ADT data with simulated electron diffraction data for virtual nanocrystals, built with different ratios of BEA/BEB. In this way, it is demonstrated that this smart interplay of the above-mentioned techniques allows the elaboration of the real structures of functional materials in detail - even if they possess a severely disordered structure.

  7. Early Intervention for Children with Conduct Disorders: A Quantitative Synthesis of Single-Subject Research.

    Science.gov (United States)

    Scruggs, Thomas E.; And Others

    1986-01-01

    Sixteen studies were analyzed that employed single-subject designs focusing on conduct disorders in preschoolers. Results indicated that reinforcement produced most positive outcomes, followed by punishment, timeout, and differential attention. Subject characteristics such as sex, handicapping condition, and target behavior typically bore little…

  8. Qualitative or Quantitative Differences between Asperger's Disorder and Autism? Historical Considerations

    Science.gov (United States)

    Sanders, James Ladell

    2009-01-01

    The histories of autism and Asperger's Disorder (AD), based on original contributions by Kanner and Asperger, are reviewed in relation to DSM-IV diagnostic criteria. Their original articles appear to have influenced the distinction between AD and autism made in the DSM-IV. Based on up-to-date empirical research, however, it appears that AD and…

  9. Quantitative electroencephalogram (QEEG) Spectrum Analysis of Patients with Schizoaffective Disorder Compared to Normal Subjects.

    Science.gov (United States)

    Moeini, Mahdi; Khaleghi, Ali; Amiri, Nasrin; Niknam, Zahra

    2014-10-01

    The aim of this study was to achieve a better understanding of schizoaffective disorder. Therefore, we obtained electroencephalogram (EEG) signals from patients with schizoaffective disorder and analyzed them in comparison to normal subjects. Forty patients with schizoaffective disorder and 40 normal subjects were selected randomly and their electroencephalogram signals were recorded based on 10-20 international system by 23 electrodes in open- and closed-eyes while they were sitting on a chair comfortably. After preprocessing for noise removal and artifact reduction, we took 60- second segments from each recorded signals. Then, the absolute and relative powers of these segments were evaluated in all channels and in 4 frequency bands (i.e., delta, theta, alpha and beta waves). Finally, Data were analyzed by independent t-test using SPSS software. A significant decrease in relative power in the alpha band, a significant decrease in power spectra in the alpha band and a significant increase in power spectra in the beta band were found in patients compared to normal subjects (P schizoaffective patients, it can be concluded that schizoaffective disorder can be seen in schizophrenia spectrum.

  10. Alterations of the cerebellum and basal ganglia in bipolar disorder mood states detected by quantitative T1ρ mapping.

    Science.gov (United States)

    Johnson, Casey P; Christensen, Gary E; Fiedorowicz, Jess G; Mani, Merry; Shaffer, Joseph J; Magnotta, Vincent A; Wemmie, John A

    2018-01-07

    Quantitative mapping of T1 relaxation in the rotating frame (T1ρ) is a magnetic resonance imaging technique sensitive to pH and other cellular and microstructural factors, and is a potentially valuable tool for identifying brain alterations in bipolar disorder. Recently, this technique identified differences in the cerebellum and cerebral white matter of euthymic patients vs healthy controls that were consistent with reduced pH in these regions, suggesting an underlying metabolic abnormality. The current study built upon this prior work to investigate brain T1ρ differences across euthymic, depressed, and manic mood states of bipolar disorder. Forty participants with bipolar I disorder and 29 healthy control participants matched for age and gender were enrolled. Participants with bipolar disorder were imaged in one or more mood states, yielding 27, 12, and 13 imaging sessions in euthymic, depressed, and manic mood states, respectively. Three-dimensional, whole-brain anatomical images and T1ρ maps were acquired for all participants, enabling voxel-wise evaluation of T1ρ differences between bipolar mood state and healthy control groups. All three mood state groups had increased T1ρ relaxation times in the cerebellum compared to the healthy control group. Additionally, the depressed and manic groups had reduced T1ρ relaxation times in and around the basal ganglia compared to the control and euthymic groups. The study implicated the cerebellum and basal ganglia in the pathophysiology of bipolar disorder and its mood states, the roles of which are relatively unexplored. These findings motivate further investigation of the underlying cause of the abnormalities, and the potential role of altered metabolic activity in these regions. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. Quantitative MRI and strength measurements in the assessment of muscle quality in Duchenne muscular dystrophy.

    Science.gov (United States)

    Wokke, B H; van den Bergen, J C; Versluis, M J; Niks, E H; Milles, J; Webb, A G; van Zwet, E W; Aartsma-Rus, A; Verschuuren, J J; Kan, H E

    2014-05-01

    The purpose of this study was to assess leg muscle quality and give a detailed description of leg muscle involvement in a series of Duchenne muscular dystrophy patients using quantitative MRI and strength measurements. Fatty infiltration, as well as total and contractile (not fatty infiltrated) cross sectional areas of various leg muscles were determined in 16 Duchenne patients and 11 controls (aged 8-15). To determine specific muscle strength, four leg muscle groups (quadriceps femoris, hamstrings, anterior tibialis and triceps surae) were measured and related to the amount of contractile tissue. In patients, the quadriceps femoris showed decreased total and contractile cross sectional area, attributable to muscle atrophy. The total, but not the contractile, cross sectional area of the triceps surae was increased in patients, corresponding to hypertrophy. Specific strength decreased in all four muscle groups of Duchenne patients, indicating reduced muscle quality. This suggests that muscle hypertrophy and fatty infiltration are two distinct pathological processes, differing between muscle groups. Additionally, the quality of remaining muscle fibers is severely reduced in the legs of Duchenne patients. The combination of quantitative MRI and quantitative muscle testing could be a valuable outcome parameter in longitudinal studies and in the follow-up of therapeutic effects. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Detecting Genetic Interactions for Quantitative Traits Using m-Spacing Entropy Measure

    Directory of Open Access Journals (Sweden)

    Jaeyong Yee

    2015-01-01

    Full Text Available A number of statistical methods for detecting gene-gene interactions have been developed in genetic association studies with binary traits. However, many phenotype measures are intrinsically quantitative and categorizing continuous traits may not always be straightforward and meaningful. Association of gene-gene interactions with an observed distribution of such phenotypes needs to be investigated directly without categorization. Information gain based on entropy measure has previously been successful in identifying genetic associations with binary traits. We extend the usefulness of this information gain by proposing a nonparametric evaluation method of conditional entropy of a quantitative phenotype associated with a given genotype. Hence, the information gain can be obtained for any phenotype distribution. Because any functional form, such as Gaussian, is not assumed for the entire distribution of a trait or a given genotype, this method is expected to be robust enough to be applied to any phenotypic association data. Here, we show its use to successfully identify the main effect, as well as the genetic interactions, associated with a quantitative trait.

  13. Validation and measurement uncertainty estimation in food microbiology: differences between quantitative and qualitative methods

    Directory of Open Access Journals (Sweden)

    Vesna Režić Dereani

    2010-09-01

    Full Text Available The aim of this research is to describe quality control procedures, procedures for validation and measurement uncertainty (MU determination as an important element of quality assurance in food microbiology laboratory for qualitative and quantitative type of analysis. Accreditation is conducted according to the standard ISO 17025:2007. General requirements for the competence of testing and calibration laboratories, which guarantees the compliance with standard operating procedures and the technical competence of the staff involved in the tests, recently are widely introduced in food microbiology laboratories in Croatia. In addition to quality manual introduction, and a lot of general documents, some of the most demanding procedures in routine microbiology laboratories are measurement uncertainty (MU procedures and validation experiment design establishment. Those procedures are not standardized yet even at international level, and they require practical microbiological knowledge, altogether with statistical competence. Differences between validation experiments design for quantitative and qualitative food microbiology analysis are discussed in this research, and practical solutions are shortly described. MU for quantitative determinations is more demanding issue than qualitative MU calculation. MU calculations are based on external proficiency testing data and internal validation data. In this paper, practical schematic descriptions for both procedures are shown.

  14. Visual characterization and quantitative measurement of artemisinin-induced DNA breakage

    Energy Technology Data Exchange (ETDEWEB)

    Cai Huaihong [Bionanotechnology Lab, and Department of Chemistry, Jinan University, Guangzhou 510632 (China); Yang Peihui [Bionanotechnology Lab, and Department of Chemistry, Jinan University, Guangzhou 510632 (China)], E-mail: typh@jnu.edu.cn; Chen Jianan [Bionanotechnology Lab, and Department of Chemistry, Jinan University, Guangzhou 510632 (China); Liang Zhihong [Experiment and Technology Center, Jinan University, Guangzhou 510632 (China); Chen Qiongyu [Institute of Genetic Engineering, Jinan University, Guangzhou 510632 (China); Cai Jiye [Bionanotechnology Lab, and Department of Chemistry, Jinan University, Guangzhou 510632 (China)], E-mail: tjycai@jnu.edu.cn

    2009-05-01

    DNA conformational change and breakage induced by artemisinin, a traditional Chinese herbal medicine, have been visually characterized and quantitatively measured by the multiple tools of electrochemistry, UV-vis absorption spectroscopy, atomic force microscopy (AFM), and DNA electrophoresis. Electrochemical and spectroscopic results confirm that artemisinin can intercalate into DNA double helix, which causes DNA conformational changes. AFM imaging vividly demonstrates uneven DNA strand breaking induced by QHS interaction. To assess these DNA breakages, quantitative analysis of the extent of DNA breakage has been performed by analyzing AFM images. Basing on the statistical analysis, the occurrence of DNA breaks is found to depend on the concentration of artemisinin. DNA electrophoresis further validates that the intact DNA molecules are unwound due to the breakages occur at the single strands. A reliable scheme is proposed to explain the process of artemisinin-induced DNA cleavage. These results can provide further information for better understanding the anticancer activity of artemisinin.

  15. Quantitative measurement of ultraviolet-induced damage in cellular DNA by an enzyme immunodot assay

    International Nuclear Information System (INIS)

    Wakizaka, A.; Nishizawa, Y.; Aiba, N.; Okuhara, E.; Takahashi, S.

    1989-01-01

    A simple enzyme immunoassay procedure was developed for the quantitative determination of 254-nm uv-induced DNA damage in cells. With the use of specific antibodies to uv-irradiated DNA and horseradish peroxidase-conjugated antibody to rabbit IgG, the extent of damaged DNA in uv-irradiated rat spleen mononuclear cells was quantitatively measurable. Through the use of this method, the amount of damaged DNA present in 2 X 10(5) cells irradiated at a dose of 75 J/m2 was estimated to be 7 ng equivalents of the standard uv-irradiated DNA. In addition, when the cells, irradiated at 750 J/m2, were incubated for 1 h, the antigenic activity of DNA decreased by 40%, suggesting that a repair of the damaged sites in DNA had proceeded to some extent in the cells

  16. Diurnal Hypothalamic-Pituitary-Adrenal Axis Measures and Inflammatory Marker Correlates in Major Depressive Disorder

    Directory of Open Access Journals (Sweden)

    Kelly Doolin

    2017-10-01

    Full Text Available Dysregulation of the hypothalamic-pituitary-adrenal (HPA axis and inflammatory systems is a consistent finding in patients with Major Depressive Disorder (MDD. Cortisol is often assessed by measurement of the cortisol awakening response (CAR and/or diurnal cortisol levels. Some methods of cortisol measurement overestimate cortisol concentration due to detection of other glucocorticoids including the relatively inert cortisone, therefore this study aimed to assess the presence of both cortisol and cortisone, and the cortisol-cortisone catalyzing enzyme 11β-hydroxysteroiddehydrogenase type 1 (11β-HSD1, in depressed patients and controls. Because the HPA axis is known to regulate the body’s immune system, relationships between measures of cytokines and cortisol were also assessed. Saliva samples were collected from 57 MDD patients and 40 healthy controls at five post-wakening time points (0, +30, +60, +720 and +750 min. Glucocorticoid concentrations were measured by liquid chromatography mass spectrometry. Whole blood mRNA expression of several inflammatory markers was measured by quantitative polymerase chain reaction. This study replicated the common finding of elevated morning cortisol and reduced CAR reactivity in MDD and found no differences in cortisone or 11β-HSD1 mRNA measures. There was a negative association between interleukin 1-β (IL-1β mRNA and morning cortisol reactivity within the depressed group, indicating that dysregulation of the HPA axis and immune system may be interconnected.

  17. Quantitative measurement of blood circulation in tests of rats using nuclear medical methods

    International Nuclear Information System (INIS)

    Ripke, R.

    1980-01-01

    The experiments show that is it is possible to quantitatively assess the blood circulation and, within limits, the germinative function of tests by measuring the impulses of an incorporated radionuclide (99-Tc-pertechnetate) using an uptake measuring instrument. This is a rapid and unbloody method to be adopted in human medicine. 'Acute tests' or pre-damaged tests can thus be exactly diagnosed. In the former case the circulation modification and in the latter the evaluation of the germinative function ability is of main interest. The most important measuring criterion is the 15-minute-uptake U; it represents the blood circulation in the tests measured. The germinative function ability is evaluated on the basis of the accumulation activity Nsub(max). (orig./MG) [de

  18. High temperature and high pressure gas cell for quantitative spectroscopic measurements

    International Nuclear Information System (INIS)

    Christiansen, Caspar; Stolberg-Rohr, Thomine; Fateev, Alexander; Clausen, Sønnik

    2016-01-01

    A high temperature and high pressure gas cell (HTPGC) has been manufactured for quantitative spectroscopic measurements in the pressure range 1–200 bar and temperature range 300–1300 K. In the present work the cell was employed at up to 100 bar and 1000 K, and measured absorption coefficients of a CO_2–N_2 mixture at 100 bar and 1000 K are revealed for the first time, exceeding the high temperature and pressure combinations previously reported. This paper discusses the design considerations involved in the construction of the cell and presents validation measurements compared against simulated spectra, as well as published experimental data. - Highlights: • A ceramic gas cell designed for gas measurements up to 1300 K and 200 bar. • The first recorded absorption spectrum of CO_2 at 1000 K and 101 bar is presented. • Voigt profiles might suffice in the modeling of radiation from CO_2 in combustion.

  19. Conduct disorders as a result of specific learning disorders

    OpenAIRE

    VOKROJOVÁ, Nela

    2012-01-01

    This thesis focuses on relationship between specific learning disorders and conduct disorders in puberty. The theoretical part explains the basic terms apearing in the thesis such as specific learning disorders, conduct disorders, puberty and prevention of conduct disorder formation. It presents Czech and foreign research which have already been done in this and related areas. The empirical part uses a quantitative method to measure anxiety and occurrence of conduct disorders in second grade ...

  20. Do cognitive measures of response inhibition differentiate between attention deficit/hyperactivity disorder and borderline personality disorder?

    NARCIS (Netherlands)

    Dijk, F.E. van; Schellekens, A.F.A.; Broek, P.J.A. van den; Kan, C.C.; Verkes, R.J.; Buitelaar, J.K.

    2014-01-01

    This study examined whether cognitive measures of response inhibition derived from the AX-CPT are able to differentiate between adult attention deficit/hyperactivity disorder (ADHD), borderline personality disorder (BPD), and healthy controls (HC). Current DSM-IV-TR symptoms of ADHD and BPD were

  1. Quantitative lymphoscintigraphy in post-mastectomy lymphedema: correlation with circumferential measurements

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Joon Young; Lee, Kyung Han; Kim, Sang Eun; Kim, Byung Tae; Hwang, Jee Hea; Lee, Byung Boong [Samsung Medical Center, Seoul (Korea, Republic of)

    1997-07-01

    An objective measure for the severity and progression is important for the management of lymphedema. To evaluate the usefulness of lympho-scintigraphy in this regard, we compared various quantitative indices from upper extremity lymphoscintigraphy with circumferential measurements, before and after physiotheraphy. Upper extremity lymphoscintigraphy was performed in 38 patients with unilateral postmastectomy lymphedema. Tc-99m antimony sulfide colloid (37 MBq) was injected s.c. into the second and third interdigital spaces. The injection sites were imaged immediately after injection. After standardized exercise for 15 min, upper extremity images were acquired 30 min, 1 hr and 2 hr after injection. The clearance of the injection site (CL), and % uptake in regional lymph nodes (%LN) and soft tissue of the extremity (i.e., the degree of dermal backflow) (%EXT) compared to the initial injection site were calculated. Circumference of each extremity was measured at 7 levels; the severity of lymphedema was expressed as the percentage difference of total circumferential difference (TCD) between healthy and edematous extremities compared to the total circumference of healthy extremity (%TCD). In 19 patients who received physiotherapy, the therapeutic effect was measured by % decrease of TCD (%DTCD) before and after therapy (Raines. et al., 1977). The quantitative indices calculated in the image at 2 hr p.i. had better correlation with either %TCD or %DTCD than those from earlier images (Table). The CL, %LN and %EXT of edematous extremity had a significant correlation with TCD. The %EXT was correlated best with either TCD or %DTCD. The results suggest that the %EXT which corresponds to the degree of dermal backflow may be a simple and useful quantitative index for evaluating the severity and progression in lymphedema and predicting the effect of therapy.

  2. Measuring teamwork in primary care: Triangulation of qualitative and quantitative data.

    Science.gov (United States)

    Brown, Judith Belle; Ryan, Bridget L; Thorpe, Cathy; Markle, Emma K R; Hutchison, Brian; Glazier, Richard H

    2015-09-01

    This article describes the triangulation of qualitative dimensions, reflecting high functioning teams, with the results of standardized teamwork measures. The study used a mixed methods design using qualitative and quantitative approaches to assess teamwork in 19 Family Health Teams in Ontario, Canada. This article describes dimensions from the qualitative phase using grounded theory to explore the issues and challenges to teamwork. Two quantitative measures were used in the study, the Team Climate Inventory (TCI) and the Providing Effective Resources and Knowledge (PERK) scale. For the triangulation analysis, the mean scores of these measures were compared with the qualitatively derived ratings for the dimensions. The final sample for the qualitative component was 107 participants. The qualitative analysis identified 9 dimensions related to high team functioning such as common philosophy, scope of practice, conflict resolution, change management, leadership, and team evolution. From these dimensions, teams were categorized numerically as high, moderate, or low functioning. Three hundred seventeen team members completed the survey measures. Mean site scores for the TCI and PERK were 3.87 and 3.88, respectively (of 5). The TCI was associated will all dimensions except for team location, space allocation, and executive director leadership. The PERK was associated with all dimensions except team location. Data triangulation provided qualitative and quantitative evidence of what constitutes teamwork. Leadership was pivotal in forging a common philosophy and encouraging team collaboration. Teams used conflict resolution strategies and adapted to the changes they encountered. These dimensions advanced the team's evolution toward a high functioning team. (c) 2015 APA, all rights reserved).

  3. Quantitative lymphoscintigraphy in post-mastectomy lymphedema: correlation with circumferential measurements

    International Nuclear Information System (INIS)

    Choi, Joon Young; Lee, Kyung Han; Kim, Sang Eun; Kim, Byung Tae; Hwang, Jee Hea; Lee, Byung Boong

    1997-01-01

    An objective measure for the severity and progression is important for the management of lymphedema. To evaluate the usefulness of lympho-scintigraphy in this regard, we compared various quantitative indices from upper extremity lymphoscintigraphy with circumferential measurements, before and after physiotheraphy. Upper extremity lymphoscintigraphy was performed in 38 patients with unilateral postmastectomy lymphedema. Tc-99m antimony sulfide colloid (37 MBq) was injected s.c. into the second and third interdigital spaces. The injection sites were imaged immediately after injection. After standardized exercise for 15 min, upper extremity images were acquired 30 min, 1 hr and 2 hr after injection. The clearance of the injection site (CL), and % uptake in regional lymph nodes (%LN) and soft tissue of the extremity (i.e., the degree of dermal backflow) (%EXT) compared to the initial injection site were calculated. Circumference of each extremity was measured at 7 levels; the severity of lymphedema was expressed as the percentage difference of total circumferential difference (TCD) between healthy and edematous extremities compared to the total circumference of healthy extremity (%TCD). In 19 patients who received physiotherapy, the therapeutic effect was measured by % decrease of TCD (%DTCD) before and after therapy (Raines. et al., 1977). The quantitative indices calculated in the image at 2 hr p.i. had better correlation with either %TCD or %DTCD than those from earlier images (Table). The CL, %LN and %EXT of edematous extremity had a significant correlation with TCD. The %EXT was correlated best with either TCD or %DTCD. The results suggest that the %EXT which corresponds to the degree of dermal backflow may be a simple and useful quantitative index for evaluating the severity and progression in lymphedema and predicting the effect of therapy

  4. Quantitative electroencephalogram (QEEG Spectrum Analysis of Patients with Schizoaffective Disorder Compared to Normal Subjects.

    Directory of Open Access Journals (Sweden)

    Mahdi Moeini

    2014-12-01

    Full Text Available The aim of this study was to achieve a better understanding of schizoaffective disorder. Therefore, we obtained electroencephalogram (EEG signals from patients with schizoaffective disorder and analyzed them in comparison to normal subjects.Forty patients with schizoaffective disorder and 40 normal subjects were selected randomly and their electroencephalogram signals were recorded based on 10-20 international system by 23 electrodes in open- and closed-eyes while they were sitting on a chair comfortably. After preprocessing for noise removal and artifact reduction, we took 60- second segments from each recorded signals. Then, the absolute and relative powers of these segments were evaluated in all channels and in 4 frequency bands (i.e., delta, theta, alpha and beta waves. Finally, Data were analyzed by independent t-test using SPSS software.A significant decrease in relative power in the alpha band, a significant decrease in power spectra in the alpha band and a significant increase in power spectra in the beta band were found in patients compared to normal subjects (P < 0.05. The predominant wave in the centro-parietal region was the beta wave in patients, but it was the alpha band in normal subjects (P = 0.048. Also, the predominant wave of the occipital region in patients was the delta wave, while it was the alpha wave in normal subjects (P = 0.038.Considering the findings, particularly based on the significant decrease of the alpha waves in schizoaffective patients, it can be concluded that schizoaffective disorder can be seen in schizophrenia spectrum.

  5. Quantitative and Isolated Measurement of Far-Field Light Scattering by a Single Nanostructure

    Science.gov (United States)

    Kim, Donghyeong; Jeong, Kwang-Yong; Kim, Jinhyung; Ee, Ho-Seok; Kang, Ju-Hyung; Park, Hong-Gyu; Seo, Min-Kyo

    2017-11-01

    Light scattering by nanostructures has facilitated research on various optical phenomena and applications by interfacing the near fields and free-propagating radiation. However, direct quantitative measurement of far-field scattering by a single nanostructure on the wavelength scale or less is highly challenging. Conventional back-focal-plane imaging covers only a limited solid angle determined by the numerical aperture of the objectives and suffers from optical aberration and distortion. Here, we present a quantitative measurement of the differential far-field scattering cross section of a single nanostructure over the full hemisphere. In goniometer-based far-field scanning with a high signal-to-noise ratio of approximately 27.4 dB, weak scattering signals are efficiently isolated and detected under total-internal-reflection illumination. Systematic measurements reveal that the total and differential scattering cross sections of a Au nanorod are determined by the plasmonic Fabry-Perot resonances and the phase-matching conditions to the free-propagating radiation, respectively. We believe that our angle-resolved far-field measurement scheme provides a way to investigate and evaluate the physical properties and performance of nano-optical materials and phenomena.

  6. Miniature rainbow schlieren deflectometry system for quantitative measurements in microjets and flames

    International Nuclear Information System (INIS)

    Satti, Rajani P.; Kolhe, Pankaj S.; Olcmen, Semih; Agrawal, Ajay K.

    2007-01-01

    Recent interest in small-scale flow devices has created the need for miniature instruments capable of measuring scalar flow properties with high spatial resolution. We present a miniature rainbow schlieren deflectometry system to nonintrusively obtain quantitative species concentration and temperature data across the whole field. The optical layout of the miniature system is similar to that of a macroscale system, although the field of view is smaller by an order of magnitude. Employing achromatic lenses and a CCD array together with a camera lens and extension tubes, we achieved spatial resolution down to 4 μm. Quantitative measurements required a careful evaluation of the optical components. The capability of the system is demonstrated by obtaining concentration measurements in a helium microjet (diameter, d=650 μm) and temperature and concentration measurements in a hydrogen jet diffusion flame from a microinjector(d=50 μm). Further, the flow field of underexpanded nitrogen jets is visualized to reveal details of the shock structures existing downstream of the jet exit

  7. A quantitative and qualitative evaluation of trainee opinions of four methods of personality disorder diagnosis.

    Science.gov (United States)

    Nelson, Sharon M; Huprich, Steven K; Shankar, Sneha; Sohnleitner, Aimee; Paggeot, Amy V

    2017-07-01

    Four methods of how to assess and diagnose personality disorders have received much attention within the literature: the Shedler-Westen Assessment Procedure (Shedler & Westen, 1998), the DSM-5 Section III Personality Disorders section (APA, 2011), the DSM-5 Section III trait model (APA, 2013), and the Psychodynamic Diagnostic Manual (PDM; PDM Task Force, 2006) descriptions of 15 personality disorders. Given that much of the debate has been driven by clinician concerns, it is important to consider clinical utility when evaluating the usefulness of each method. The present study compares the 4 models on ratings of several dimensions of clinical utility provided by 329 graduate student clinicians and psychology interns from across the United States. Findings suggest that participants rated the DSM-5 trait model significantly higher in most clinical utility domains. Additionally, qualitative analyses of the open-ended responses provided by participants indicated that each method had strengths and weaknesses. Most notably, participants commented positively on the PDM's level of comprehensiveness and appreciated the SWAP-II's inclusion of a health category, despite the ease of use not being as highly rated for these methods. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  8. Virtual reality exposure therapy in anxiety disorders: a quantitative meta-analysis.

    Science.gov (United States)

    Opriş, David; Pintea, Sebastian; García-Palacios, Azucena; Botella, Cristina; Szamosközi, Ştefan; David, Daniel

    2012-02-01

    Virtual reality exposure therapy (VRET) is a promising intervention for the treatment of the anxiety disorders. The main objective of this meta-analysis is to compare the efficacy of VRET, used in a behavioral or cognitive-behavioral framework, with that of the classical evidence-based treatments, in anxiety disorders. A comprehensive search of the literature identified 23 studies (n = 608) that were included in the final analysis. The results show that in the case of anxiety disorders, (1) VRET does far better than the waitlist control; (2) the post-treatment results show similar efficacy between the behavioral and the cognitive behavioral interventions incorporating a virtual reality exposure component and the classical evidence-based interventions, with no virtual reality exposure component; (3) VRET has a powerful real-life impact, similar to that of the classical evidence-based treatments; (4) VRET has a good stability of results over time, similar to that of the classical evidence-based treatments; (5) there is a dose-response relationship for VRET; and (6) there is no difference in the dropout rate between the virtual reality exposure and the in vivo exposure. Implications are discussed. © 2011 Wiley Periodicals, Inc.

  9. Brief Report: The Smiles of a Child with Autism Spectrum Disorder during an Animal-Assisted Activity May Facilitate Social Positive Behaviors--Quantitative Analysis with Smile-Detecting Interface

    Science.gov (United States)

    Funahashi, Atsushi; Gruebler, Anna; Aoki, Takeshi; Kadone, Hideki; Suzuki, Kenji

    2014-01-01

    We quantitatively measured the smiles of a child with autism spectrum disorder (ASD-C) using a wearable interface device during animal-assisted activities (AAA) for 7 months, and compared the results with a control of the same age. The participant was a 10-year-old boy with ASD, and a normal healthy boy of the same age was the control. They…

  10. Capsular Outcomes After Pediatric Cataract Surgery Without Intraocular Lens Implantation: Qualitative Classification and Quantitative Measurement.

    Science.gov (United States)

    Tan, Xuhua; Lin, Haotian; Lin, Zhuoling; Chen, Jingjing; Tang, Xiangchen; Luo, Lixia; Chen, Weirong; Liu, Yizhi

    2016-03-01

    The objective of this study was to investigate capsular outcomes 12 months after pediatric cataract surgery without intraocular lens implantation via qualitative classification and quantitative measurement.This study is a cross-sectional study that was approved by the institutional review board of Zhongshan Ophthalmic Center of Sun Yat-sen University in Guangzhou, China.Digital coaxial retro-illumination photographs of 329 aphakic pediatric eyes were obtained 12 months after pediatric cataract surgery without intraocular lens implantation. Capsule digital coaxial retro-illumination photographs were divided as follows: anterior capsule opening area (ACOA), posterior capsule opening area (PCOA), and posterior capsule opening opacity (PCOO). Capsular outcomes were qualitatively classified into 3 types based on the PCOO: Type I-capsule with mild opacification but no invasion into the capsule opening; Type II-capsule with moderate opacification accompanied by contraction of the ACOA and invasion to the occluding part of the PCOA; and Type III-capsule with severe opacification accompanied by total occlusion of the PCOA. Software was developed to quantitatively measure the ACOA, PCOA, and PCOO using standardized DCRPs. The relationships between the accurate intraoperative anterior and posterior capsulorhexis sizes and the qualitative capsular types were statistically analyzed.The DCRPs of 315 aphakic eyes (95.8%) of 191 children were included. Capsular outcomes were classified into 3 types: Type I-120 eyes (38.1%); Type II-157 eyes (49.8%); Type III-38 eyes (12.1%). The scores of the capsular outcomes were negatively correlated with intraoperative anterior capsulorhexis size (R = -0.572, P PCOA increased in size from Type I to Type II, and the PCOO increased from Type II to Type III (all P < 0.05).Capsular outcomes after pediatric cataract surgery can be qualitatively classified and quantitatively measured by acquisition, division, definition, and user

  11. Quantitative dual energy CT measurements in rabbit VX2 liver tumors: Comparison to perfusion CT measurements and histopathological findings

    International Nuclear Information System (INIS)

    Zhang, Long Jiang; Wu, Shengyong; Wang, Mei; Lu, Li; Chen, Bo; Jin, Lixin; Wang, Jiandong; Larson, Andrew C.; Lu, Guang Ming

    2012-01-01

    Purpose: To evaluate the correlation between quantitative dual energy CT and perfusion CT measurements in rabbit VX2 liver tumors. Materials and methods: This study was approved by the institutional animal care and use committee at our institution. Nine rabbits with VX2 liver tumors underwent contrast-enhanced dual energy CT and perfusion CT. CT attenuation for the tumors and normal liver parenchyma and tumor-to-liver ratio were obtained at the 140 kVp, 80 kVp, average weighted images and dual energy CT iodine maps. Quantitative parameters for the viable tumor and adjacent liver were measured with perfusion CT. The correlation between the enhancement values of the tumor in iodine maps and perfusion CT parameters of each tumor was analyzed. Radiation dose from dual energy CT and perfusion CT was measured. Results: Enhancement values for the tumor were higher than that for normal liver parenchyma at the hepatic arterial phase (P < 0.05). The highest tumor-to-liver ratio was obtained in hepatic arterial phase iodine map. Hepatic blood flow of the tumor was higher than that for adjacent liver (P < 0.05). Enhancement values of hepatic tumors in the iodine maps positively correlated with permeability of capillary vessel surface (r = 0.913, P < 0.001), hepatic blood flow (r = 0.512, P = 0.010), and hepatic blood volume (r = 0.464, P = 0.022) at the hepatic arterial phases. The effective radiation dose from perfusion CT was higher than that from DECT (P < 0.001). Conclusions: The enhancement values for viable tumor tissues measured in iodine maps were well correlated to perfusion CT measurements in rabbit VX2 liver tumors. Compared with perfusion CT, dual energy CT of the liver required a lower radiation dose.

  12. Piezoelectric tuning fork biosensors for the quantitative measurement of biomolecular interactions

    International Nuclear Information System (INIS)

    Gonzalez, Laura; Maria Benito, Angel; Puig-Vidal, Manel; Otero, Jorge; Rodrigues, Mafalda; Pérez-García, Lluïsa

    2015-01-01

    The quantitative measurement of biomolecular interactions is of great interest in molecular biology. Atomic force microscopy (AFM) has proved its capacity to act as a biosensor and determine the affinity between biomolecules of interest. Nevertheless, the detection scheme presents certain limitations when it comes to developing a compact biosensor. Recently, piezoelectric quartz tuning forks (QTFs) have been used as laser-free detection sensors for AFM. However, only a few studies along these lines have considered soft biological samples, and even fewer constitute quantified molecular recognition experiments. Here, we demonstrate the capacity of QTF probes to perform specific interaction measurements between biotin–streptavidin complexes in buffer solution. We propose in this paper a variant of dynamic force spectroscopy based on representing adhesion energies E (aJ) against pulling rates v (nm s"–"1). Our results are compared with conventional AFM measurements and show the great potential of these sensors in molecular interaction studies. (paper)

  13. Electrons, Photons, and Force: Quantitative Single-Molecule Measurements from Physics to Biology

    Science.gov (United States)

    2011-01-01

    Single-molecule measurement techniques have illuminated unprecedented details of chemical behavior, including observations of the motion of a single molecule on a surface, and even the vibration of a single bond within a molecule. Such measurements are critical to our understanding of entities ranging from single atoms to the most complex protein assemblies. We provide an overview of the strikingly diverse classes of measurements that can be used to quantify single-molecule properties, including those of single macromolecules and single molecular assemblies, and discuss the quantitative insights they provide. Examples are drawn from across the single-molecule literature, ranging from ultrahigh vacuum scanning tunneling microscopy studies of adsorbate diffusion on surfaces to fluorescence studies of protein conformational changes in solution. PMID:21338175

  14. The development of NEdSERV: quantitative instrumentation to measure service quality in nurse education.

    Science.gov (United States)

    Roberts, P

    1999-07-01

    The political climate of health care provision and education for health care in the latter years of the 20th century is evolving from the uncertainty of newly created markets to a more clearly focused culture of collaboration, dissemination of good practice, with an increased emphasis on quality provision and its measurement. The need for provider units to prove and improve efficiency and effectiveness through evidence-based quality strategies in order to stay firmly in the market place has never been more necessary. The measurement of customer expectations and perceptions of delivered service quality is widely utilized as a basis for customer retention and business growth in both commercial and non-profit organizations. This paper describes the methodological development of NEdSERV--quantitative instrumentation designed to measure and respond to ongoing stakeholder expectations and perceptions of delivered service quality within nurse education.

  15. Quantitative and simultaneous non-invasive measurement of skin hydration and sebum levels

    Science.gov (United States)

    Ezerskaia, Anna; Pereira, S. F.; Urbach, H. Paul; Verhagen, Rieko; Varghese, Babu

    2016-01-01

    We report a method on quantitative and simultaneous non-contact in-vivo hydration and sebum measurements of the skin using an infrared optical spectroscopic set-up. The method utilizes differential detection with three wavelengths 1720, 1750, and 1770 nm, corresponding to the lipid vibrational bands that lay “in between” the prominent water absorption bands. We have used an emulsifier containing hydro- and lipophilic components to mix water and sebum in various volume fractions which was applied to the skin to mimic different oily-dry skin conditions. We also measured the skin sebum and hydration values on the forehead under natural conditions and its variations to external stimuli. Good agreement was found between our experimental results and reference values measured using conventional biophysical methods such as Corneometer and Sebumeter. PMID:27375946

  16. Application of quantitative autoradiography to the measurement of biochemical processes in vivo

    International Nuclear Information System (INIS)

    Sokoloff, L.

    1985-01-01

    Quantitative autoradiography makes it possible to measure the concentrations of isotopes in tissues of animals labeled in vivo. In a few cases, the administration of a judiciously selected labeled chemical compound and a properly designed procedure has made it possible to use this capability to measure the rate of a chemical process in animals in vivo. Emission tomography, and particularly positron emission tomography, provides a means to extend this capability to man and to assay the rates of biochemical processes in human tissues in vivo. It does not, however, obviate the need to adhere to established principles of chemical and enzyme kinetics and tracer theory. Generally, all such methods, whether to be used in man with positron emission tomography or in animals with autoradiography, must first be developed by research in animals with autoradiography, because it is only in animals that the measurements needed to validate the basic assumptions of the methods can be tested and evaluated

  17. Quantitative measurements of in-cylinder gas composition in a controlled auto-ignition combustion engine

    Science.gov (United States)

    Zhao, H.; Zhang, S.

    2008-01-01

    One of the most effective means to achieve controlled auto-ignition (CAI) combustion in a gasoline engine is by the residual gas trapping method. The amount of residual gas and mixture composition have significant effects on the subsequent combustion process and engine emissions. In order to obtain quantitative measurements of in-cylinder residual gas concentration and air/fuel ratio, a spontaneous Raman scattering (SRS) system has been developed recently. The optimized optical SRS setups are presented and discussed. The temperature effect on the SRS measurement is considered and a method has been developed to correct for the overestimated values due to the temperature effect. Simultaneous measurements of O2, H2O, CO2 and fuel were obtained throughout the intake, compression, combustion and expansion strokes. It shows that the SRS can provide valuable data on this process in a CAI combustion engine.

  18. Quantitative measurements of in-cylinder gas composition in a controlled auto-ignition combustion engine

    International Nuclear Information System (INIS)

    Zhao, H; Zhang, S

    2008-01-01

    One of the most effective means to achieve controlled auto-ignition (CAI) combustion in a gasoline engine is by the residual gas trapping method. The amount of residual gas and mixture composition have significant effects on the subsequent combustion process and engine emissions. In order to obtain quantitative measurements of in-cylinder residual gas concentration and air/fuel ratio, a spontaneous Raman scattering (SRS) system has been developed recently. The optimized optical SRS setups are presented and discussed. The temperature effect on the SRS measurement is considered and a method has been developed to correct for the overestimated values due to the temperature effect. Simultaneous measurements of O 2 , H 2 O, CO 2 and fuel were obtained throughout the intake, compression, combustion and expansion strokes. It shows that the SRS can provide valuable data on this process in a CAI combustion engine

  19. Measurement of psychological disorders using cognitive diagnosis models.

    Science.gov (United States)

    Templin, Jonathan L; Henson, Robert A

    2006-09-01

    Cognitive diagnosis models are constrained (multiple classification) latent class models that characterize the relationship of questionnaire responses to a set of dichotomous latent variables. Having emanated from educational measurement, several aspects of such models seem well suited to use in psychological assessment and diagnosis. This article presents the development of a new cognitive diagnosis model for use in psychological assessment--the DINO (deterministic input; noisy "or" gate) model--which, as an illustrative example, is applied to evaluate and diagnose pathological gamblers. As part of this example, a demonstration of the estimates obtained by cognitive diagnosis models is provided. Such estimates include the probability an individual meets each of a set of dichotomous Diagnostic and Statistical Manual of Mental Disorders (text revision [DSM-IV-TR]; American Psychiatric Association, 2000) criteria, resulting in an estimate of the probability an individual meets the DSM-IV-TR definition for being a pathological gambler. Furthermore, a demonstration of how the hypothesized underlying factors contributing to pathological gambling can be measured with the DINO model is presented, through use of a covariance structure model for the tetrachoric correlation matrix of the dichotomous latent variables representing DSM-IV-TR criteria. Copyright 2006 APA

  20. Quantitation of chemical exchange rates using pulsed-field-gradient diffusion measurements

    International Nuclear Information System (INIS)

    Andrec, Michael; Prestegard, James H.

    1997-01-01

    A new approach to the quantitation of chemical exchange rates is presented, and its utility is illustrated with application to the exchange of protein amide protons with bulk water. The approach consists of a selective-inversion exchange HMQC experiment in which a short spin echo diffusion filter has been inserted into the exchange period. In this way, the kinetics of exchange are encoded directly in an apparent diffusion coefficient which is a function of the position of the diffusion filter in the pulse sequence. A detailed theoretical analysis of this experiment indicates that, in addition to the measurement of simple exchange rates, the experiment is capable of measuring the effect of mediated exchange, e.g. the transfer of magnetization from bulk water to an amide site mediated by an internal bound water molecule or a labile protein side-chain proton in fast exchange with bulk water. Experimental results for rapid water/amide exchange in acyl carrier protein are shown to be quantitatively consistent with the exchange rates measured using a selective-inversion exchange experiment

  1. Quantitative measurement and visualization of biofilm O 2 consumption rates in membrane filtration systems

    KAUST Repository

    Prest, Emmanuelle I E C

    2012-03-01

    There is a strong need for techniques enabling direct assessment of biological activity of biofouling in membrane filtration systems. Here we present a new quantitative and non-destructive method for mapping O 2 dynamics in biofilms during biofouling studies in membrane fouling simulators (MFS). Transparent planar O 2 optodes in combination with a luminescence lifetime imaging system were used to map the two-dimensional distribution of O 2 concentrations and consumption rates inside the MFS. The O 2 distribution was indicative for biofilm development. Biofilm activity was characterized by imaging of O 2 consumption rates, where low and high activity areas could be clearly distinguished. The spatial development of O 2 consumption rates, flow channels and stagnant areas could be determined. This can be used for studies on concentration polarization, i.e. salt accumulation at the membrane surface resulting in increased salt passage and reduced water flux. The new optode-based O 2 imaging technique applied to MFS allows non-destructive and spatially resolved quantitative biological activity measurements (BAM) for on-site biofouling diagnosis and laboratory studies. The following set of complementary tools is now available to study development and control of biofouling in membrane systems: (i) MFS, (ii) sensitive pressure drop measurement, (iii) magnetic resonance imaging, (iv) numerical modelling, and (v) biological activity measurement based on O 2 imaging methodology. © 2011 Elsevier B.V.

  2. A rapid and quantitative assay for measuring antibody-mediated neutralization of West Nile virus infection

    International Nuclear Information System (INIS)

    Pierson, Theodore C.; Sanchez, Melissa D.; Puffer, Bridget A.; Ahmed, Asim A.; Geiss, Brian J.; Valentine, Laura E.; Altamura, Louis A.; Diamond, Michael S.; Doms, Robert W.

    2006-01-01

    West Nile virus (WNV) is a neurotropic flavivirus within the Japanese encephalitis antigenic complex that is responsible for causing West Nile encephalitis in humans. The surface of WNV virions is covered by a highly ordered icosahedral array of envelope proteins that is responsible for mediating attachment and fusion with target cells. These envelope proteins are also primary targets for the generation of neutralizing antibodies in vivo. In this study, we describe a novel approach for measuring antibody-mediated neutralization of WNV infection using virus-like particles that measure infection as a function of reporter gene expression. These reporter virus particles (RVPs) are produced by complementation of a sub-genomic replicon with WNV structural proteins provided in trans using conventional DNA expression vectors. The precision and accuracy of this approach stem from an ability to measure the outcome of the interaction between antibody and viral antigens under conditions that satisfy the assumptions of the law of mass action as applied to virus neutralization. In addition to its quantitative strengths, this approach allows the production of WNV RVPs bearing the prM-E proteins of different WNV strains and mutants, offering considerable flexibility for the study of the humoral immune response to WNV in vitro. WNV RVPs are capable of only a single round of infection, can be used under BSL-2 conditions, and offer a rapid and quantitative approach for detecting virus entry and its inhibition by neutralizing antibody

  3. A quantitative meta-analysis of neurocognitive functioning in posttraumatic stress disorder

    Science.gov (United States)

    Scott, J. Cobb; Matt, Georg E.; Wrocklage, Kristen M.; Crnich, Cassandra; Jordan, Jessica; Southwick, Steven M.; Krystal, John H.; Schweinsburg, Brian C.

    2014-01-01

    Posttraumatic stress disorder (PTSD) is associated with regional alterations in brain structure and function that are hypothesized to contribute to symptoms and cognitive deficits associated with the disorder. We present here the first systematic meta-analysis of neurocognitive outcomes associated with PTSD to examine a broad range of cognitive domains and describe the profile of cognitive deficits, as well as modifying clinical factors and study characteristics. This report is based on data from 60 studies totaling 4,108 participants, including 1,779with PTSD, 1,446 trauma-exposed comparison participants, and 895 healthy comparison participants without trauma exposure. Effect size estimates were calculated using a mixed-effects meta-analysis for nine cognitive domains: attention/working memory, executive functions, verbal learning, verbal memory, visual learning, visual memory, language, speed of information processing, and visuospatial abilities. Analyses revealed significant neurocognitive effects associated with PTSD, although these ranged widely in magnitude, with the largest effect sizes in verbal learning (d =−.62), speed of information processing (d =−.59), attention/working memory (d =−.50), and verbal memory (d =−.46). Effect size estimates were significantly larger in treatment-seeking than community samples and in studies that did not exclude participants with attention-deficit hyperactivity disorder, and effect sizes were affected by between-group IQ discrepancies and the gender composition of the PTSD groups. Our findings indicate that consideration of neuropsychological functioning in attention, verbal memory, and speed of information processing may have important implications for the effective clinical management of persons with PTSD. Results are further discussed in the context of cognitive models of PTSD and the limitations of this literature. PMID:25365762

  4. Human CLOCK gene-associated attention deficit hyperactivity disorder-related features in healthy adults: quantitative association study using Wender Utah Rating Scale.

    Science.gov (United States)

    Jeong, Seong Hoon; Yu, Je-Chun; Lee, Chang Hwa; Choi, Kyeong-Sook; Choi, Jung-Eun; Kim, Se Hyun; Joo, Eun-Jeong

    2014-02-01

    Circadian rhythm disturbance is highly prevalent in attention deficit hyperactivity disorder (ADHD). Recently, the association between the CLOCK gene and ADHD has been demonstrated in clinical samples, and the CLOCK gene's role was thought to be mediated by rhythm dysregulation. Meanwhile, ADHD has been suggested as the extreme end of a continuously distributed trait that can be found in the general population. Therefore, we examined two possibilities: (1) an ADHD-related continuous trait may be associated with the CLOCK gene, and (2) this association may be mediated by the degree of individuals' evening preference. To explore these possibilities, we performed a quantitative trait locus association study with a sample of 1,289 healthy adults. The Wender Utah Rating Scale (WURS) and the Composite Scale of Morningness (CSM) were utilized to measure the quantitative traits. Quantitative association analysis was performed using PLINK software. We found that rs1801260 (=T3111C) was associated with WURS scores in both allele-wise (p = 0.018) and haplotype-wise analyses (range of p values: 0.0155-0.0171) in male participants only. After controlling for the CSM total score as a covariate, the strength of the association did not change at all, suggesting that the association was not mediated by evening preference. Despite the very weak association signal, our results provide evidence that the CLOCK gene's association with ADHD in clinical samples may be generalizable to traits measured in the normal population. However, as our results failed to show a mediating role of evening preference, ongoing efforts are needed to identify the mechanisms by which the CLOCK gene determines ADHD-related traits.

  5. Selecting quantitative water management measures at the river basin scale in a global change context

    Science.gov (United States)

    Girard, Corentin; Rinaudo, Jean-Daniel; Caballero, Yvan; Pulido-Velazquez, Manuel

    2013-04-01

    One of the main challenges in the implementation of the Water Framework Directive (WFD) in the European Union is the definition of programme of measures to reach the good status of the European water bodies. In areas where water scarcity is an issue, one of these challenges is the selection of water conservation and capacity expansion measures to ensure minimum environmental in-stream flow requirements. At the same time, the WFD calls for the use of economic analysis to identify the most cost-effective combination of measures at the river basin scale to achieve its objective. With this respect, hydro-economic river basin models, by integrating economics, environmental and hydrological aspects at the river basin scale in a consistent framework, represent a promising approach. This article presents a least-cost river basin optimization model (LCRBOM) that selects the combination of quantitative water management measures to meet environmental flows for future scenarios of agricultural and urban demand taken into account the impact of the climate change. The model has been implemented in a case study on a Mediterranean basin in the south of France, the Orb River basin. The water basin has been identified as in need for quantitative water management measures in order to reach the good status of its water bodies. The LCRBOM has been developed using GAMS, applying Mixed Integer Linear Programming. It is run to select the set of measures that minimizes the total annualized cost of the applied measures, while meeting the demands and minimum in-stream flow constraints. For the economic analysis, the programme of measures is composed of water conservation measures on agricultural and urban water demands. It compares them with measures mobilizing new water resources coming from groundwater, inter-basin transfers and improvement in reservoir operating rules. The total annual cost of each measure is calculated for each demand unit considering operation, maintenance and

  6. Quantitative facial asymmetry: using three-dimensional photogrammetry to measure baseline facial surface symmetry.

    Science.gov (United States)

    Taylor, Helena O; Morrison, Clinton S; Linden, Olivia; Phillips, Benjamin; Chang, Johnny; Byrne, Margaret E; Sullivan, Stephen R; Forrest, Christopher R

    2014-01-01

    Although symmetry is hailed as a fundamental goal of aesthetic and reconstructive surgery, our tools for measuring this outcome have been limited and subjective. With the advent of three-dimensional photogrammetry, surface geometry can be captured, manipulated, and measured quantitatively. Until now, few normative data existed with regard to facial surface symmetry. Here, we present a method for reproducibly calculating overall facial symmetry and present normative data on 100 subjects. We enrolled 100 volunteers who underwent three-dimensional photogrammetry of their faces in repose. We collected demographic data on age, sex, and race and subjectively scored facial symmetry. We calculated the root mean square deviation (RMSD) between the native and reflected faces, reflecting about a plane of maximum symmetry. We analyzed the interobserver reliability of the subjective assessment of facial asymmetry and the quantitative measurements and compared the subjective and objective values. We also classified areas of greatest asymmetry as localized to the upper, middle, or lower facial thirds. This cluster of normative data was compared with a group of patients with subtle but increasing amounts of facial asymmetry. We imaged 100 subjects by three-dimensional photogrammetry. There was a poor interobserver correlation between subjective assessments of asymmetry (r = 0.56). There was a high interobserver reliability for quantitative measurements of facial symmetry RMSD calculations (r = 0.91-0.95). The mean RMSD for this normative population was found to be 0.80 ± 0.24 mm. Areas of greatest asymmetry were distributed as follows: 10% upper facial third, 49% central facial third, and 41% lower facial third. Precise measurement permitted discrimination of subtle facial asymmetry within this normative group and distinguished norms from patients with subtle facial asymmetry, with placement of RMSDs along an asymmetry ruler. Facial surface symmetry, which is poorly assessed

  7. Measuring self-esteem in dieting disordered patients: the validity of the Rosenberg and Coopersmith contrasted.

    Science.gov (United States)

    Griffiths, R A; Beumont, P J; Giannakopoulos, E; Russell, J; Schotte, D; Thornton, C; Touyz, S W; Varano, P

    1999-03-01

    In order to ascertain the most appropriate measure of self-esteem for dieting disordered patients, this study contrasted the construct and convergent validities of two widely used measures. In addition, dieting disordered subgroups were compared on levels of self-esteem. One hundred and seventeen male and female patients diagnosed with anorexia nervosa, bulimia nervosa, or eating disorder not otherwise specified completed the Rosenberg Self-Esteem Scale (SES), the Coopersmith Self-Esteem Inventory (SEI), and measures of dieting disorder pathology and depression. No significant differences among the three dieting disorder subgroups were found. In determining convergent validity, regression analyses indicated that the SES was a significant predictor of dieting disorder psychopathology whereas the SEI was not. Of the two self-esteem measures, only the SES showed evidence of convergent validity. The results suggest that the SES has sounder construct and convergent validity than the SEI. Hence, the SES may be more appropriate for use with dieting disordered populations.

  8. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan [Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States)

    2009-11-15

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  9. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    International Nuclear Information System (INIS)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan

    2009-01-01

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 μm 2 ). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0±5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO DSA =CO Fick . Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  10. Psychometric Testing of the Personal Internet Gaming Disorder Evaluation-9: A New Measure Designed to Assess Internet Gaming Disorder.

    Science.gov (United States)

    Pearcy, Benjamin T D; Roberts, Lynne D; McEvoy, Peter M

    2016-05-01

    Internet Gaming Disorder (IGD) is in the early stages of recognition as a disorder, following its inclusion in the Diagnostic and Statistical Manual for Mental Disorders (DSM-5; American Psychiatric Association(1)) as a condition for further study. Existing measures of Internet gaming pathology are limited in their ability to measure IGD as defined in the DSM-5. We present the initial development and validation of a new measure derived from the proposed DSM-5 criteria for IGD, the Personal Internet Gaming Disorder Evaluation-9 (PIE-9). A student sample (n = 119) and a community sample (n = 285), sourced through a variety of online gaming forums, completed an online survey comprising the new measure, existing measures of IGD, and a range of health and demographic questions. Exploratory and confirmatory factor analysis supported a single factor structure for the 9-item PIE-9. Internal consistency (α = 0.89) and test-retest reliability (intraclass correlation [ICC] = 0.77) were high. Convergent validity was demonstrated with similar gaming addiction measures. Predictive validity was established through significant differences in distress and disability between those who met the criteria for IGD and those who did not. The distress and disability associated with meeting IGD criteria fell within the range of other common DSM-5 disorders. Preliminary testing of the PIE-9 has demonstrated that it is an efficient and straightforward measure for use in further research of IGD, and as a potential screening measure in clinical practice.

  11. Quantitative method for measurement of the Goos-Hanchen effect based on source divergence considerations

    International Nuclear Information System (INIS)

    Gray, Jeffrey F.; Puri, Ashok

    2007-01-01

    In this paper we report on a method for quantitative measurement and characterization of the Goos-Hanchen effect based upon the real world performance of optical sources. A numerical model of a nonideal plane wave is developed in terms of uniform divergence properties. This model is applied to the Goos-Hanchen shift equations to determine beam shift displacement characteristics, which provides quantitative estimates of finite shifts near critical angle. As a potential technique for carrying out a meaningful comparison with experiments, a classical method of edge detection is discussed. To this end a line spread Green's function is defined which can be used to determine the effective transfer function of the near critical angle behavior of divergent plane waves. The process yields a distributed (blurred) output with a line spread function characteristic of the inverse square root nature of the Goos-Hanchen shift equation. A parameter of interest for measurement is given by the edge shift function. Modern imaging and image processing methods provide suitable techniques for exploiting the edge shift phenomena to attain refractive index sensitivities of the order of 10 -6 , comparable with the recent results reported in the literature

  12. Do Quantitative Measures of Research Productivity Correlate with Academic Rank in Oral and Maxillofacial Surgery?

    Science.gov (United States)

    Susarla, Srinivas M; Dodson, Thomas B; Lopez, Joseph; Swanson, Edward W; Calotta, Nicholas; Peacock, Zachary S

    2015-08-01

    Academic promotion is linked to research productivity. The purpose of this study was to assess the correlation between quantitative measures of academic productivity and academic rank among academic oral and maxillofacial surgeons. This was a cross-sectional study of full-time academic oral and maxillofacial surgeons in the United States. The predictor variables were categorized as demographic (gender, medical degree, research doctorate, other advanced degree) and quantitative measures of academic productivity (total number of publications, total number of citations, maximum number of citations for a single article, I-10 index [number of publications with ≥ 10 citations], and h-index [number of publications h with ≥ h citations each]). The outcome variable was current academic rank (instructor, assistant professor, associate professor, professor, or endowed professor). Descriptive, bivariate, and multiple regression statistics were computed to evaluate associations between the predictors and academic rank. Receiver-operator characteristic curves were computed to identify thresholds for academic promotion. The sample consisted of 324 academic oral and maxillofacial surgeons, of whom 11.7% were female, 40% had medical degrees, and 8% had research doctorates. The h-index was the most strongly correlated with academic rank (ρ = 0.62, p research activity.

  13. An Introduction to Quantitative Measures for Software Maintenance of Nuclear Power Plant

    International Nuclear Information System (INIS)

    Jo, Hyun Jun; Seong, Poong Hyun

    2007-01-01

    The I and C system of NPP has changed from the analog system to the digital-based system using microcontrollers and software. Thus, software has become very important for NPP control system. The software life cycle is divided into the development and maintenance phase largely. Because poor software maintenance work introduces new errors and makes software much complex, we have to consider the effective maintenance methods for the reliability and maintainability of NPP software. Function Block Diagram (FBD) is a standard application programming language for the Programmable Logic Controller (PLC) and currently being used in the development of a fully-digitalized reactor protection system (RPS) under the KNICS project. Therefore, the maintenance work will be of great importance in a few years. This paper studies on the measures which give quantitative information to software maintainer and manager before and after modification. The remainder of this paper is organized as follows. Section 2 briefly describes software maintenance types and model. In Section 3-5, we introduce the quantitative measures for software maintenance and characteristics of FBD program. A conclusion is provided in Section 6

  14. Quantitative head ultrasound measurements to determine thresholds for preterm neonates requiring interventional therapies following intraventricular hemorrhage

    Science.gov (United States)

    Kishimoto, Jessica; Fenster, Aaron; Salehi, Fateme; Romano, Walter; Lee, David S. C.; de Ribaupierre, Sandrine

    2016-04-01

    Dilation of the cerebral ventricles is a common condition in preterm neonates with intraventricular hemorrhage (IVH). This post hemorrhagic ventricle dilation (PHVD) can lead to lifelong neurological impairment through ischemic injury due to increased intracranial pressure and without treatment, can lead to death. Clinically, 2D ultrasound (US) through the fontanelles ('soft spots') of the patients are serially acquired to monitor the progression of the ventricle dilation. These images are used to determine when interventional therapies such as needle aspiration of the built up cerebrospinal fluid (CSF) ('ventricle tap', VT) might be indicated for a patient; however, quantitative measurements of the growth of the ventricles are often not performed. There is no consensus on when a neonate with PHVD should have an intervention and often interventions are performed after the potential for brain damage is quite high. Previously we have developed and validated a 3D US system to monitor the progression of ventricle volumes (VV) in IVH patients. We will describe the potential utility of quantitative 2D and 3D US to monitor and manage PHVD in neonates. Specifically, we will look to determine image-based measurement thresholds for patients who will require VT in comparison to patients with PHVD who resolve without intervention. Additionally, since many patients who have an initial VT will require subsequent interventions, we look at the potential for US to determine which PHVD patients will require additional VT after the initial one has been performed.

  15. Quantitative measurement of phase variation amplitude of ultrasonic diffraction grating based on diffraction spectral analysis

    Energy Technology Data Exchange (ETDEWEB)

    Pan, Meiyan, E-mail: yphantomohive@gmail.com; Zeng, Yingzhi; Huang, Zuohua, E-mail: zuohuah@163.com [Laboratory of Quantum Engineering and Quantum Materials, School of Physics and Telecommunication Engineering, South China Normal University, Guangzhou, Guangdong 510006 (China)

    2014-09-15

    A new method based on diffraction spectral analysis is proposed for the quantitative measurement of the phase variation amplitude of an ultrasonic diffraction grating. For a traveling wave, the phase variation amplitude of the grating depends on the intensity of the zeroth- and first-order diffraction waves. By contrast, for a standing wave, this amplitude depends on the intensity of the zeroth-, first-, and second-order diffraction waves. The proposed method is verified experimentally. The measured phase variation amplitude ranges from 0 to 2π, with a relative error of approximately 5%. A nearly linear relation exists between the phase variation amplitude and driving voltage. Our proposed method can also be applied to ordinary sinusoidal phase grating.

  16. Are Quantitative Measures of Academic Productivity Correlated with Academic Rank in Plastic Surgery? A National Study.

    Science.gov (United States)

    Susarla, Srinivas M; Lopez, Joseph; Swanson, Edward W; Miller, Devin; O'Brien-Coon, Devin; Zins, James E; Serletti, Joseph M; Yaremchuk, Michael J; Manson, Paul N; Gordon, Chad R

    2015-09-01

    The purpose of this study was to investigate the correlation between quantitative measures of academic productivity and academic rank among full-time academic plastic surgeons. Bibliometric indices were computed for all full-time academic plastic surgeons in the United States. The primary study variable was academic rank. Bibliometric predictors included the Hirsch index, I-10 index, number of publications, number of citations, and highest number of citations for a single publication. Descriptive, bivariate, and correlation analyses were computed. Multiple comparisons testing was used to calculate adjusted associations for subgroups. For all analyses, a value of p productivity. Although academic promotion is the result of success in multiple different areas, bibliometric measures may be useful adjuncts for assessment of research productivity.

  17. Predicting Eating Disorders in Women: A Preliminary Measurement Study.

    Science.gov (United States)

    Lundholm, Jean K; And Others

    1989-01-01

    Identified items from Millon Clinical Multiaxial Inventory (MCMI) that differentiated eating-disordered women (n=173) currently receiving treatment for bulimia from non-eating-disordered university women (n=265). Results identified a list of statements related to social withdrawal and depression that may be appropriate for use in assessing a…

  18. Plasma kynurenine and related measures in tic disorder patients

    NARCIS (Netherlands)

    Hoekstra, Pieter J.; Anderson, George M.; Troost, Pieter W.; Kallenberg, Cees G. M.; Minderaa, Ruud B.

    Objective Increased plasma kynurenine has been reported in tic disorder patients, and this observation has been suggested to be indicative of immune dysregulation. In the present study, we examined plasma levels of kynurenine and related molecules in a group of tic disorder patients. Methods Plasma

  19. Verifax: Biometric instruments measuring neuromuscular disorders/performance impairments

    Science.gov (United States)

    Morgenthaler, George W.; Shrairman, Ruth; Landau, Alexander

    1998-01-01

    VeriFax, founded in 1990 by Dr. Ruth Shrairman and Mr. Alex Landau, began operations with the aim of developing a biometric tool for the verification of signatures from a distance. In the course of developing this VeriFax Autograph technology, two other related applications for the technologies under development at VeriFax became apparent. The first application was in the use of biometric measurements as clinical monitoring tools for physicians investigating neuromuscular diseases (embodied in VeriFax's Neuroskill technology). The second application was to evaluate persons with critical skills (e.g., airline pilots, bus drivers) for physical and mental performance impairments caused by stress, physiological disorders, alcohol, drug abuse, etc. (represented by VeriFax's Impairoscope prototype instrument). This last application raised the possibility of using a space-qualified Impairoscope variant to evaluate astronaut performance with respect to the impacts of stress, fatigue, excessive workload, build-up of toxic chemicals within the space habitat, etc. The three applications of VeriFax's patented technology are accomplished by application-specific modifications of the customized VeriFax software. Strong commercial market potentials exist for all three VeriFax technology applications, and market progress will be presented in more detail below.

  20. Challenges in the management of nutritional disorders and communicable diseases in child day care centers: a quantitative and qualitative approach.

    Science.gov (United States)

    Konstantyner, Tulio; Konstantyner, Thais Cláudia Roma de Oliveira; Toloni, Maysa Helena Aguiar; Longo-Silva, Giovana; Taddei, José Augusto de Aguiar Carrazedo

    2017-03-01

    In Brazil, although many children from low income families attend day care centers with appropriate hygiene practices and food programs, they have nutritional disorders and communicable diseases. This quantitative and qualitative cross-sectional study identified staff challenges in child day care centers and suggested alternative activity management to prevent nutritional disorders and communicable diseases. The study included 71 nursery teachers and 270 children from public and philanthropic day care centers (teacher to child ratios of 1:2.57 and 1:6.40, respectively). Interviews and focus groups were conducted with teachers and parents, and anthropometry and blood samples were drawn from the children by digital puncture. Children in philanthropic child day care centers were more likely to be hospitalized due to communicable diseases. Teachers from philanthropic child day care centers had lower age, income and education and higher work responsibilities based on the number of children and working time. The focus groups characterized institutions with organized routines, standard food practices, difficulties with caretaking, and lack of training to provide healthcare to children. Strategies to improve children's health in day care settings should focus on training of teachers about healthcare and nutrition.

  1. Non-invasive tissue temperature measurements based on quantitative diffuse optical spectroscopy (DOS) of water

    Energy Technology Data Exchange (ETDEWEB)

    Chung, S H [Department of Physics and Astronomy, University of Pennsylvania, 209 South 33rd Street, Philadelphia, PA 19104 (United States); Cerussi, A E; Tromberg, B J [Beckman Laser Institute and Medical Clinic, University of California, Irvine, 1002 Health Sciences Road, Irvine 92612, CA (United States); Merritt, S I [Masimo Corporation, 40 Parker, Irvine, CA 92618 (United States); Ruth, J, E-mail: bjtrombe@uci.ed [Department of Bioengineering, University of Pennsylvania, 210 S. 33rd Street, Room 240, Skirkanich Hall, Philadelphia, PA 19104 (United States)

    2010-07-07

    We describe the development of a non-invasive method for quantitative tissue temperature measurements using Broadband diffuse optical spectroscopy (DOS). Our approach is based on well-characterized opposing shifts in near-infrared (NIR) water absorption spectra that appear with temperature and macromolecular binding state. Unlike conventional reflectance methods, DOS is used to generate scattering-corrected tissue water absorption spectra. This allows us to separate the macromolecular bound water contribution from the thermally induced spectral shift using the temperature isosbestic point at 996 nm. The method was validated in intralipid tissue phantoms by correlating DOS with thermistor measurements (R = 0.96) with a difference of 1.1 {+-} 0.91 {sup 0}C over a range of 28-48 {sup 0}C. Once validated, thermal and hemodynamic (i.e. oxy- and deoxy-hemoglobin concentration) changes were measured simultaneously and continuously in human subjects (forearm) during mild cold stress. DOS-measured arm temperatures were consistent with previously reported invasive deep tissue temperature studies. These results suggest that DOS can be used for non-invasive, co-registered measurements of absolute temperature and hemoglobin parameters in thick tissues, a potentially important approach for optimizing thermal diagnostics and therapeutics.

  2. The fear of food measure: a novel measure for use in exposure therapy for eating disorders.

    Science.gov (United States)

    Levinson, Cheri A; Byrne, Meghan

    2015-04-01

    Exposure therapy for mealtime anxiety has preliminarily been effective at increasing food intake and decreasing anxiety in individuals with anorexia nervosa (AN). To enhance our knowledge of exposure therapy for AN researchers and clinicians need a comprehensive measure that assesses outcomes relevant to exposure therapy for AN. In the current four studies we developed Fear of Food Measure (FOFM) that assesses three cognitive and behavioral outcomes: trait anxiety about eating, food avoidance behaviors, and feared concerns related to eating. In a community (N = 399) and undergraduate female sample (N = 203) the FOFM exhibited a good three-factor structure and convergent and divergent validity. In a sample of women (N = 72) we showed that the anxiety about eating subscale significantly predicted in vivo food intake over and above other established predictors of eating (e.g., restraint). In a clinical sample diagnosed with an eating disorder (N = 41) we showed that anxiety about eating was associated with food intake and anxiety during an exposure meal and that all subscales of the FOFM significantly decreased over the course of a four-session exposure intervention. Finally, we found that participants diagnosed with an eating disorder had higher levels of fear of food than did matched controls (N = 23). The FOFM is a psychometrically valid measure that can assess if patients are improving while undergoing exposure therapy and could be used to pinpoint problematic behaviors that can be addressed in exposure therapy. © 2014 Wiley Periodicals, Inc.

  3. Extracting quantitative structural parameters for disordered polymers from neutron scattering data

    International Nuclear Information System (INIS)

    Rosi-Schwartz, B.; Mitchell, G.R.

    1995-01-01

    The organization of non-crystalline polymeric materials at a local level, namely on a spatial scale between a few and 100 A, is still unclear in many respects. The determination of the local structure in terms of the configuration and conformation of the polymer chain and of the packing characteristics of the chain in the bulk material represents a challenging problem. Data from wide-angle diffraction experiments are very difficult to interpret due to the very large amount of information that they carry, that is the large number of correlations present in the diffraction patterns.We describe new approaches that permit a detailed analysis of the complex neutron diffraction patterns characterizing polymer melts and glasses. The coupling of different computer modelling strategies with neutron scattering data over a wide Q range allows the extraction of detailed quantitative information on the structural arrangements of the materials of interest. Proceeding from modelling routes as diverse as force field calculations, single-chain modelling and reverse Monte Carlo, we show the successes and pitfalls of each approach in describing model systems, which illustrate the need to attack the data analysis problem simultaneously from several fronts. ((orig.))

  4. Cross-method validation as a solution to the problem of excessive simplification of measurement in quantitative IR research

    DEFF Research Database (Denmark)

    Beach, Derek

    2007-01-01

    The purpose of this article is to make IR scholars more aware of the costs of choosing quantitative methods. The article first shows that quantification can have analytical ‘costs’ when the measures created are too simple to capture the essence of the systematized concept that was supposed...... detail based upon a review of the democratic peace literature. I then offer two positive suggestions for a way forward. First, I argue that quantitative scholars should spend more time validating their measures, and in particular should engage in multi-method partnerships with qualitative scholars...... that have a deep understanding of particular cases in order to exploit the comparative advantages of qualitative methodology, using the more accurate qualitative measures to validate their own quantitative measures. Secondly, quantitative scholars should lower their level of ambition given the often poor...

  5. First experiences with model based iterative reconstructions influence on quantitative plaque volume and intensity measurements in coronary computed tomography angiography

    DEFF Research Database (Denmark)

    Precht, Helle; Kitslaar, Pieter H.; Broersen, Alexander

    2017-01-01

    Purpose: Investigate the influence of adaptive statistical iterative reconstruction (ASIR) and the model- based IR (Veo) reconstruction algorithm in coronary computed tomography angiography (CCTA) im- ages on quantitative measurements in coronary arteries for plaque volumes and intensities. Methods...

  6. Epithelium percentage estimation facilitates epithelial quantitative protein measurement in tissue specimens.

    Science.gov (United States)

    Chen, Jing; Toghi Eshghi, Shadi; Bova, George Steven; Li, Qing Kay; Li, Xingde; Zhang, Hui

    2013-12-01

    The rapid advancement of high-throughput tools for quantitative measurement of proteins has demonstrated the potential for the identification of proteins associated with cancer. However, the quantitative results on cancer tissue specimens are usually confounded by tissue heterogeneity, e.g. regions with cancer usually have significantly higher epithelium content yet lower stromal content. It is therefore necessary to develop a tool to facilitate the interpretation of the results of protein measurements in tissue specimens. Epithelial cell adhesion molecule (EpCAM) and cathepsin L (CTSL) are two epithelial proteins whose expressions in normal and tumorous prostate tissues were confirmed by measuring staining intensity with immunohistochemical staining (IHC). The expressions of these proteins were measured by ELISA in protein extracts from OCT embedded frozen prostate tissues. To eliminate the influence of tissue heterogeneity on epithelial protein quantification measured by ELISA, a color-based segmentation method was developed in-house for estimation of epithelium content using H&E histology slides from the same prostate tissues and the estimated epithelium percentage was used to normalize the ELISA results. The epithelium contents of the same slides were also estimated by a pathologist and used to normalize the ELISA results. The computer based results were compared with the pathologist's reading. We found that both EpCAM and CTSL levels, measured by ELISA assays itself, were greatly affected by epithelium content in the tissue specimens. Without adjusting for epithelium percentage, both EpCAM and CTSL levels appeared significantly higher in tumor tissues than normal tissues with a p value less than 0.001. However, after normalization by the epithelium percentage, ELISA measurements of both EpCAM and CTSL were in agreement with IHC staining results, showing a significant increase only in EpCAM with no difference in CTSL expression in cancer tissues. These results

  7. Quantitative approach for optimizing e-beam condition of photoresist inspection and measurement

    Science.gov (United States)

    Lin, Chia-Jen; Teng, Chia-Hao; Cheng, Po-Chung; Sato, Yoshishige; Huang, Shang-Chieh; Chen, Chu-En; Maruyama, Kotaro; Yamazaki, Yuichiro

    2018-03-01

    Severe process margin in advanced technology node of semiconductor device is controlled by e-beam metrology system and e-beam inspection system with scanning electron microscopy (SEM) image. By using SEM, larger area image with higher image quality is required to collect massive amount of data for metrology and to detect defect in a large area for inspection. Although photoresist is the one of the critical process in semiconductor device manufacturing, observing photoresist pattern by SEM image is crucial and troublesome especially in the case of large image. The charging effect by e-beam irradiation on photoresist pattern causes deterioration of image quality, and it affect CD variation on metrology system and causes difficulties to continue defect inspection in a long time for a large area. In this study, we established a quantitative approach for optimizing e-beam condition with "Die to Database" algorithm of NGR3500 on photoresist pattern to minimize charging effect. And we enhanced the performance of measurement and inspection on photoresist pattern by using optimized e-beam condition. NGR3500 is the geometry verification system based on "Die to Database" algorithm which compares SEM image with design data [1]. By comparing SEM image and design data, key performance indicator (KPI) of SEM image such as "Sharpness", "S/N", "Gray level variation in FOV", "Image shift" can be retrieved. These KPIs were analyzed with different e-beam conditions which consist of "Landing Energy", "Probe Current", "Scanning Speed" and "Scanning Method", and the best e-beam condition could be achieved with maximum image quality, maximum scanning speed and minimum image shift. On this quantitative approach of optimizing e-beam condition, we could observe dependency of SEM condition on photoresist charging. By using optimized e-beam condition, measurement could be continued on photoresist pattern over 24 hours stably. KPIs of SEM image proved image quality during measurement and

  8. Quantitative Measures of Immersion in Cloud and the Biogeography of Cloud Forests

    Science.gov (United States)

    Lawton, R. O.; Nair, U. S.; Ray, D.; Regmi, A.; Pounds, J. A.; Welch, R. M.

    2010-01-01

    Sites described as tropical montane cloud forests differ greatly, in part because observers tend to differ in their opinion as to what constitutes frequent and prolonged immersion in cloud. This definitional difficulty interferes with hydrologic analyses, assessments of environmental impacts on ecosystems, and biogeographical analyses of cloud forest communities and species. Quantitative measurements of cloud immersion can be obtained on site, but the observations are necessarily spatially limited, although well-placed observers can examine 10 50 km of a mountain range under rainless conditions. Regional analyses, however, require observations at a broader scale. This chapter discusses remote sensing and modeling approaches that can provide quantitative measures of the spatiotemporal patterns of cloud cover and cloud immersion in tropical mountain ranges. These approaches integrate remote sensing tools of various spatial resolutions and frequencies of observation, digital elevation models, regional atmospheric models, and ground-based observations to provide measures of cloud cover, cloud base height, and the intersection of cloud and terrain. This combined approach was applied to the Monteverde region of northern Costa Rica to illustrate how the proportion of time the forest is immersed in cloud may vary spatially and temporally. The observed spatial variation was largely due to patterns of airflow over the mountains. The temporal variation reflected the diurnal rise and fall of the orographic cloud base, which was influenced in turn by synoptic weather conditions, the seasonal movement of the Intertropical Convergence Zone and the north-easterly trade winds. Knowledge of the proportion of the time that sites are immersed in clouds should facilitate ecological comparisons and biogeographical analyses, as well as land use planning and hydrologic assessments in areas where intensive on-site work is not feasible.

  9. Cerenkov radiation imaging as a method for quantitative measurements of beta particles in a microfluidic chip

    International Nuclear Information System (INIS)

    Cho, Jennifer S; Taschereau, Richard; Olma, Sebastian; Liu Kan; Chen Yichun; Shen, Clifton K-F; Van Dam, R Michael; Chatziioannou, Arion F

    2009-01-01

    It has been observed that microfluidic chips used for synthesizing 18 F-labeled compounds demonstrate visible light emission without nearby scintillators or fluorescent materials. The origin of the light was investigated and found to be consistent with the emission characteristics from Cerenkov radiation. Since 18 F decays through the emission of high-energy positrons, the energy threshold for beta particles, i.e. electrons or positrons, to generate Cerenkov radiation was calculated for water and polydimethylsiloxane (PDMS), the most commonly used polymer-based material for microfluidic chips. Beta particles emitted from 18 F have a continuous energy spectrum, with a maximum energy that exceeds this energy threshold for both water and PDMS. In addition, the spectral characteristics of the emitted light from 18 F in distilled water were also measured, yielding a broad distribution from 300 nm to 700 nm, with higher intensity at shorter wavelengths. A photograph of the 18 F solution showed a bluish-white light emitted from the solution, further suggesting Cerenkov radiation. In this study, the feasibility of using this Cerenkov light emission as a method for quantitative measurements of the radioactivity within the microfluidic chip in situ was evaluated. A detector previously developed for imaging microfluidic platforms was used. The detector consisted of a charge-coupled device (CCD) optically coupled to a lens. The system spatial resolution, minimum detectable activity and dynamic range were evaluated. In addition, the calibration of a Cerenkov signal versus activity concentration in the microfluidic chip was determined. This novel method of Cerenkov radiation measurements will provide researchers with a simple yet robust quantitative imaging tool for microfluidic applications utilizing beta particles.

  10. Quantitative measurement of normal and hydrocephalic cerebrospinal fluid flow using phase contrast cine MR imaging

    International Nuclear Information System (INIS)

    Katayama, Shinji; Asari, Shoji; Ohmoto, Takashi

    1993-01-01

    Measurements of the cerebrospinal fluid (CSF) flow using phase contrast cine magnetic resonance (MR) imaging were performed on a phantom, 12 normal subjects and 20 patients with normal pressure hydrocephalus (NPH). The phantom study demonstrated the applicability of phase contrast in quantitative measurement of the slow flow. The CSF flows of the normal subjects showed a consistent pattern with a to-and-fro movement of the flow in the anterior subarachnoid space at the C2/3 level, and they were dependent on the cardiac cycle in all subjects. However, the patients with NPH showed variable patterns of the CSF pulsatile flow and these patterns could be divided into four types according to velocity and amplitude. The amplitudes of each type were as follows: type 0 (n=1), 87.6 mm; type I (n=2), 58.2 mm (mean); type II (n=6), 48.0±5.0 mm (mean±SEM); and type III (n=11), 19.9±1.8 mm (mean±SEM). The decrease of the amplitudes correlated to a worsening of the clinical symptoms. After the shunting operation, the amplitude of to-and-fro movement of the CSF increased again in the patients with NPH who improved clinically. Some of the type III cases were reclassified type II, I and 0 and also one of the type II cases changed type I after the shunting operation. We conclude that the phase contrast cine MR imaging is a practically and clinically applicable technique for the quantitative measurement of the CSF flow. (author)

  11. Quantitative computed tomography measurements of emphysema for diagnosing asthma-chronic obstructive pulmonary disease overlap syndrome

    Science.gov (United States)

    Xie, Mengshuang; Wang, Wei; Dou, Shuang; Cui, Liwei; Xiao, Wei

    2016-01-01

    Background The diagnostic criteria of asthma–COPD overlap syndrome (ACOS) are controversial. Emphysema is characteristic of COPD and usually does not exist in typical asthma patients. Emphysema in patients with asthma suggests the coexistence of COPD. Quantitative computed tomography (CT) allows repeated evaluation of emphysema noninvasively. We investigated the value of quantitative CT measurements of emphysema in the diagnosis of ACOS. Methods This study included 404 participants; 151 asthma patients, 125 COPD patients, and 128 normal control subjects. All the participants underwent pulmonary function tests and a high-resolution CT scan. Emphysema measurements were taken with an Airway Inspector software. The asthma patients were divided into high and low emphysema index (EI) groups based on the percentage of low attenuation areas less than −950 Hounsfield units. The characteristics of asthma patients with high EI were compared with those having low EI or COPD. Results The normal value of percentage of low attenuation areas less than −950 Hounsfield units in Chinese aged >40 years was 2.79%±2.37%. COPD patients indicated more severe emphysema and more upper-zone-predominant distribution of emphysema than asthma patients or controls. Thirty-two (21.2%) of the 151 asthma patients had high EI. Compared with asthma patients with low EI, those with high EI were significantly older, more likely to be male, had more pack-years of smoking, had more upper-zone-predominant distribution of emphysema, and had greater airflow limitation. There were no significant differences in sex ratios, pack-years of smoking, airflow limitation, or emphysema distribution between asthma patients with high EI and COPD patients. A greater number of acute exacerbations were seen in asthma patients with high EI compared with those with low EI or COPD. Conclusion Asthma patients with high EI fulfill the features of ACOS, as described in the Global Initiative for Asthma and Global

  12. MEASURING ORGANIZATIONAL CULTURE: A QUANTITATIVE-COMPARATIVE ANALYSIS [doi: 10.5329/RECADM.20100902007

    Directory of Open Access Journals (Sweden)

    Valderí de Castro Alcântara

    2010-11-01

    Full Text Available This article aims at the analysis of the organizational culture at enterprises located in two towns with distinct quantitative traits, Rio Paranaíba and Araxá. While the surveyed enterprises in Rio Paranaíba are mostly micro and small enterprises (86%, in Araxá there are mostly medium and large companies (53%. The overall objective is to verify if there are significant differences in organizational culture among these enterprises and if they can be explained by the organization size. The research was quantitative and instruments for data collection were a questionnaire and a scale for measuring organizational culture containing four dimensions: Hierarchical Distance Index (IDH, Individualism Index (INDI, Masculinity Index (MASC and the Uncertainty Control Index (CINC. Tabulation and analysis of data were performed using the PASW Statistics 18, doing descriptive and inferential statistical procedures. Using a Reduction Factor (-21 the achieved indexes were classified into 5 intensity categories (from "very low" to "very high". The Student t test for two means was performed, revealing significant differences in Hierarchical Distance and Individualism between Araxá and Rio Paranaíba enterprises (p <0.05.   Keywords Organizational Culture; Dimensions of Organizational Culture; Araxá; Rio Paranaíba.

  13. Quantitative images of metals in plant tissues measured by laser ablation inductively coupled plasma mass spectrometry

    International Nuclear Information System (INIS)

    Becker, J.S.; Dietrich, R.C.; Matusch, A.; Pozebon, D.; Dressler, V.L.

    2008-01-01

    Laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) was used for quantitative imaging of toxic and essential elements in thin sections (thickness of 30 or 40 μm) of tobacco plant tissues. Two-dimensional images of Mg, Fe, Mn, Zn, Cu, Cd, Rh, Pt and Pb in leaves, shoots and roots of tobacco were produced. Sections of the plant tissues (fixed onto glass slides) were scanned by a focused beam of a Nd:YAG laser in a laser ablation chamber. The ablated material was transported with argon as carrier gas to the ICP ion source at a quadrupole ICP-MS instrument. Ion intensities of the investigated elements were measured together with 13 C + , 33 S + and 34 S + within the entire plant tissue section. Matrix matching standards (prepared using powder of dried tobacco leaves) were used to constitute calibration curves, whereas the regression coefficient of the attained calibration curves was typically 0.99. The variability of LA-ICP-MS process, sample heterogeneity and water content in the sample were corrected by using 13 C + as internal standard. Quantitative imaging of the selected elements revealed their inhomogeneous distribution in leaves, shoots and roots

  14. Evaluation of quantitative PCR measurement of bacterial colonization of epithelial cells.

    Science.gov (United States)

    Schmidt, Marcin T; Olejnik-Schmidt, Agnieszka K; Myszka, Kamila; Borkowska, Monika; Grajek, Włodzimierz

    2010-01-01

    Microbial colonization is an important step in establishing pathogenic or probiotic relations to host cells and in biofilm formation on industrial or medical devices. The aim of this work was to verify the applicability of quantitative PCR (Real-Time PCR) to measure bacterial colonization of epithelial cells. Salmonella enterica and Caco-2 intestinal epithelial cell line was used as a model. To verify sensitivity of the assay a competition of the pathogen cells to probiotic microorganism was tested. The qPCR method was compared to plate count and radiolabel approach, which are well established techniques in this area of research. The three methods returned similar results. The best quantification accuracy had radiolabel method, followed by qPCR. The plate count results showed coefficient of variation two-times higher than this of qPCR. The quantitative PCR proved to be a reliable method for enumeration of microbes in colonization assay. It has several advantages that make it very useful in case of analyzing mixed populations, where several different species or even strains can be monitored at the same time.

  15. Nanoscale Structure of Type I Collagen Fibrils: Quantitative Measurement of D-spacing

    Science.gov (United States)

    Erickson, Blake; Fang, Ming; Wallace, Joseph M.; Orr, Bradford G.; Les, Clifford M.; Holl, Mark M. Banaszak

    2012-01-01

    This paper details a quantitative method to measure the D-periodic spacing of Type I collagen fibrils using Atomic Force Microscopy coupled with analysis using a 2D Fast Fourier Transform approach. Instrument calibration, data sampling and data analysis are all discussed and comparisons of the data to the complementary methods of electron microscopy and X-ray scattering are made. Examples of the application of this new approach to the analysis of Type I collagen morphology in disease models of estrogen depletion and Osteogenesis Imperfecta are provided. We demonstrate that it is the D-spacing distribution, not the D-spacing mean, that showed statistically significant differences in estrogen depletion associated with early stage Osteoporosis and Osteogenesis Imperfecta. The ability to quantitatively characterize nanoscale morphological features of Type I collagen fibrils will provide important structural information regarding Type I collagen in many research areas, including tissue aging and disease, tissue engineering, and gene knock out studies. Furthermore, we also envision potential clinical applications including evaluation of tissue collagen integrity under the impact of diseases or drug treatments. PMID:23027700

  16. Advances in Surface Plasmon Resonance Imaging enable quantitative measurement of laterally heterogeneous coatings of nanoscale thickness

    Science.gov (United States)

    Raegen, Adam; Reiter, Kyle; Clarke, Anthony; Lipkowski, Jacek; Dutcher, John

    2013-03-01

    The Surface Plasmon Resonance (SPR) phenomenon is routinely exploited to qualitatively probe changes to the optical properties of nanoscale coatings on thin metallic surfaces, for use in probes and sensors. Unfortunately, extracting truly quantitative information is usually limited to a select few cases - uniform absorption/desorption of small biomolecules and films, in which a continuous ``slab'' model is a good approximation. We present advancements in the SPR technique that expand the number of cases for which the technique can provide meaningful results. Use of a custom, angle-scanning SPR imaging system, together with a refined data analysis method, allow for quantitative kinetic measurements of laterally heterogeneous systems. We first demonstrate the directionally heterogeneous nature of the SPR phenomenon using a directionally ordered sample, then show how this allows for the calculation of the average coverage of a heterogeneous sample. Finally, the degradation of cellulose microfibrils and bundles of microfibrils due to the action of cellulolytic enzymes will be presented as an excellent example of the capabilities of the SPR imaging system.

  17. Lesion measurement in non-radioactive DNA by quantitative gel electrophoresis

    International Nuclear Information System (INIS)

    Sutherland, J.C.; Chen, Chun Zhang; Emrick, A.; Hacham, H; Monteleone, D.; Ribeiro, E.; Trunk, J.; Sutherland, B.M.

    1989-01-01

    The gel electrophoresis method developed during the past ten years in our laboratories makes possible the quantitation of UV induced pyrimidine dimers, gamma ray induced single- and double-strand breaks and many other types of lesions in nanogram quantities of DNA. The DNA does not have to be labeled with radionuclides or of a particular conformation, thus facilitating the use of the method in measuring damage levels and repair rates in the DNA of intact organisms -- including man. The gel method can quantitate any lesion in DNA that either is, or can be converted to a single- or double-strand break. The formation of a strand break produces two shorter DNA molecules for each molecule that existed before the treatment that produced the break. Determining the number of breaks, and hence the number of lesions, becomes a matter of comparing the average lengths of molecules in samples differing only in lesion-induced breaks. This requires that we determine the distribution of mass of DNA on a gel as a function of its distance of migration and also the dispersion function of its distance of migration and also the dispersion function (the relationship between molecular length and distance of migration) in the gel electrophoresis system. 40 refs., 5 figs

  18. Measurement of urinary free and acylcarnitines: quantitative acylcarnitine profiling in normal humans and in several patients with metabolic errors

    International Nuclear Information System (INIS)

    Montgomery, J.A.; Mamer, O.A.

    1989-01-01

    A method for determining urinary concentrations of carnitine and acylcarnitine esters is described that employs fast atom bombardment mass spectrometry, stable isotope dilution techniques, and a novel deutero-methyl esterification that permits unambiguous identification and quantitation of free carnitine and acylcarnitines. It is rapid, does not require chromatographic or other isolation procedures, and is immune to analyte losses in sample preparation. Urinary concentrations are reported for adult control subjects and for others with various metabolic disorders

  19. Residual DNA analysis in biologics development: review of measurement and quantitation technologies and future directions.

    Science.gov (United States)

    Wang, Xing; Morgan, Donna M; Wang, Gan; Mozier, Ned M

    2012-02-01

    Residual DNA (rDNA) is comprised of deoxyribonucleic acid (DNA) fragments and longer length molecules originating from the host organism that may be present in samples from recombinant biological processes. Although similar in basic structural base pair units, rDNA may exist in different sizes and physical forms. Interest in measuring rDNA in recombinant products is based primarily on demonstration of effective purification during manufacturing, but also on some hypothetical concerns that, in rare cases, depending on the host expression system, some DNA sequences may be potentially infectious or oncogenic (e.g., HIV virus and the Ras oncogene, respectively). Recent studies suggest that a sequence known as long interspersed nucleotide element-1 (LINE-1), widely distributed in the mammalian genome, is active as a retrotransposon that can be transcribed to RNA, reverse-transcribed into DNA and inserts into a new site in genome. This integration process could potentially disrupt critical gene functions or induce tumorigenesis in mammals. Genomic DNA from microbial sources, on the other hand, could add to risk of immunogenicity to the target recombinant protein being expressed, due to the high CpG content and unmethylated DNA sequence. For these and other reasons, it is necessary for manufacturers to show clearance of DNA throughout production processes and to confirm low levels in the final drug substance using an appropriately specific and quantitative analytical method. The heterogeneity of potential rDNA sequences that might be makes the testing of all potential analytes challenging. The most common methodology for rDNA quantitation used currently is real-time polymerase chain reaction (RT-PCR), a robust and proven technology. Like most rDNA quantitation methods, the specificity of RT-PCR is limited by the sequences to which the primers are directed. To address this, primase-based whole genome amplification is introduced herein. This paper will review the recent

  20. Novel gravimetric measurement technique for quantitative volume calibration in the sub-microliter range

    International Nuclear Information System (INIS)

    Liang, Dong; Zengerle, Roland; Steinert, Chris; Ernst, Andreas; Koltay, Peter; Bammesberger, Stefan; Tanguy, Laurent

    2013-01-01

    We present a novel measurement method based on the gravimetric principles adapted from the ASTM E542 and ISO 4787 standards for quantitative volume determination in the sub-microliter range. Such a method is particularly important for the calibration of non-contact micro dispensers as well as other microfluidic devices. The novel method is based on the linear regression analysis of continuously monitored gravimetric results and therefore is referred to as ‘gravimetric regression method (GRM)’. In this context, the regression analysis is necessary to compensate the mass loss due to evaporation that is significant for very small dispensing volumes. A full assessment of the measurement uncertainty of GRM is presented and results in a standard measurement uncertainty around 6 nl for dosage volumes in the range from 40 nl to 1 µl. The GRM has been experimentally benchmarked with a dual-dye ratiometric photometric method (Artel Inc., Westbrook, ME, USA), which can provide traceability of measurement to the International System of Units (SI) through reference standards maintained by NIST. Good precision (max. CV = 2.8%) and consistency (bias around 7 nl in the volume range from 40 to 400 nl) have been observed comparing the two methods. Based on the ASTM and ISO standards on the one hand and the benchmark with the photometric method on the other hand, two different approaches for establishing traceability for the GRM are discussed. (paper)

  1. Simultaneous measurement and quantitation of 4-hydroxyphenylacetic acid and dopamine with fast-scan cyclic voltammetry.

    Science.gov (United States)

    Shin, Mimi; Kaplan, Sam V; Raider, Kayla D; Johnson, Michael A

    2015-05-07

    Caged compounds have been used extensively to investigate neuronal function in a variety of preparations, including cell culture, ex vivo tissue samples, and in vivo. As a first step toward electrochemically measuring the extent of caged compound photoactivation while also measuring the release of the catecholamine neurotransmitter, dopamine, fast-scan cyclic voltammetry at carbon-fiber microelectrodes (FSCV) was used to electrochemically characterize 4-hydroxyphenylacetic acid (4HPAA) in the absence and presence of dopamine. 4HPAA is a by-product formed during the process of photoactivation of p-hydroxyphenacyl-based caged compounds, such as p-hydroxyphenylglutamate (pHP-Glu). Our data suggest that the oxidation of 4HPAA occurs through the formation of a conjugated species. Moreover, we found that a triangular waveform of -0.4 V to +1.3 V to -0.4 V at 600 V s(-1), repeated every 100 ms, provided an oxidation current of 4HPAA that was enhanced with a limit of detection of 100 nM, while also allowing the detection and quantitation of dopamine within the same scan. Along with quantifying 4HPAA in biological preparations, the results from this work will allow the electrochemical measurement of photoactivation reactions that generate 4HPAA as a by-product as well as provide a framework for measuring the photorelease of electroactive by-products from caged compounds that incorporate other chromophores.

  2. Quantitative Analysis of Oxygen Gas Exhausted from Anode through In Situ Measurement during Electrolytic Reduction

    Directory of Open Access Journals (Sweden)

    Eun-Young Choi

    2017-01-01

    Full Text Available Quantitative analysis by in situ measurement of oxygen gas evolved from an anode was employed to monitor the progress of electrolytic reduction of simulated oxide fuel in a molten Li2O–LiCl salt. The electrolytic reduction of 0.6 kg of simulated oxide fuel was performed in 5 kg of 1.5 wt.% Li2O–LiCl molten salt at 650°C. Porous cylindrical pellets of simulated oxide fuel were used as the cathode by loading a stainless steel wire mesh cathode basket. A platinum plate was employed as the anode. The oxygen gas evolved from the anode was exhausted to the instrumentation for in situ measurement during electrolytic reduction. The instrumentation consisted of a mass flow controller, pump, wet gas meter, and oxygen gas sensor. The oxygen gas was successfully measured using the instrumentation in real time. The measured volume of the oxygen gas was comparable to the theoretically calculated volume generated by the charge applied to the simulated oxide fuel.

  3. Reliability and group differences in quantitative cervicothoracic measures among individuals with and without chronic neck pain

    Science.gov (United States)

    2012-01-01

    Background Clinicians frequently rely on subjective categorization of impairments in mobility, strength, and endurance for clinical decision-making; however, these assessments are often unreliable and lack sensitivity to change. The objective of this study was to determine the inter-rater reliability, minimum detectable change (MDC), and group differences in quantitative cervicothoracic measures for individuals with and without chronic neck pain (NP). Methods Nineteen individuals with NP and 20 healthy controls participated in this case control study. Two physical therapists performed a 30-minute examination on separate days. A handheld dynamometer, gravity inclinometer, ruler, and stopwatch were used to quantify cervical range of motion (ROM), cervical muscle strength and endurance, and scapulothoracic muscle length and strength, respectively. Results Intraclass correlation coefficients for inter-rater reliability were significantly greater than zero for most impairment measures, with point estimates ranging from 0.45 to 0.93. The NP group exhibited reduced cervical ROM (P ≤ 0.012) and muscle strength (P ≤ 0.038) in most movement directions, reduced cervical extensor endurance (P = 0.029), and reduced rhomboid and middle trapezius muscle strength (P ≤ 0.049). Conclusions Results demonstrate the feasibility of obtaining objective cervicothoracic impairment measures with acceptable inter-rater agreement across time. The clinical utility of these measures is supported by evidence of impaired mobility, strength, and endurance among patients with NP, with corresponding MDC values that can help establish benchmarks for clinically significant change. PMID:23114092

  4. Quantitative method for measuring heat flux emitted from a cryogenic object

    Science.gov (United States)

    Duncan, R.V.

    1993-03-16

    The present invention is a quantitative method for measuring the total heat flux, and of deriving the total power dissipation, of a heat-fluxing object which includes the steps of placing an electrical noise-emitting heat-fluxing object in a liquid helium bath and measuring the superfluid transition temperature of the bath. The temperature of the liquid helium bath is thereafter reduced until some measurable parameter, such as the electrical noise, exhibited by the heat-fluxing object or a temperature-dependent resistive thin film in intimate contact with the heat-fluxing object, becomes greatly reduced. The temperature of the liquid helum bath is measured at this point. The difference between the superfluid transition temperature of the liquid helium bath surrounding the heat-fluxing object, and the temperature of the liquid helium bath when the electrical noise emitted by the heat-fluxing object becomes greatly reduced, is determined. The total heat flux from the heat-fluxing object is determined as a function of this difference between these temperatures. In certain applications, the technique can be used to optimize thermal design parameters of cryogenic electronics, for example, Josephson junction and infrared sensing devices.

  5. Quantitative method for measuring heat flux emitted from a cryogenic object

    International Nuclear Information System (INIS)

    Duncan, R.V.

    1993-01-01

    The present invention is a quantitative method for measuring the total heat flux, and of deriving the total power dissipation, of a heat-fluxing object which includes the steps of placing an electrical noise-emitting heat-fluxing object in a liquid helium bath and measuring the superfluid transition temperature of the bath. The temperature of the liquid helium bath is thereafter reduced until some measurable parameter, such as the electrical noise, exhibited by the heat-fluxing object or a temperature-dependent resistive thin film in intimate contact with the heat-fluxing object, becomes greatly reduced. The temperature of the liquid helum bath is measured at this point. The difference between the superfluid transition temperature of the liquid helium bath surrounding the heat-fluxing object, and the temperature of the liquid helium bath when the electrical noise emitted by the heat-fluxing object becomes greatly reduced, is determined. The total heat flux from the heat-fluxing object is determined as a function of this difference between these temperatures. In certain applications, the technique can be used to optimize thermal design parameters of cryogenic electronics, for example, Josephson junction and infrared sensing devices

  6. Directed funding to address under-provision of treatment for substance use disorders: a quantitative study.

    Science.gov (United States)

    Frakt, Austin B; Trafton, Jodie; Wallace, Amy; Neuman, Matthew; Pizer, Steven

    2013-07-18

    Substance use disorders (SUDs) are a substantial problem in the United States (U.S.), affecting far more people than receive treatment. This is true broadly and within the U.S. military veteran population, which is our focus. To increase funding for treatment, the Veterans Health Administration (VA) has implemented several initiatives over the past decade to direct funds toward SUD treatment, supplementing the unrestricted funds VA medical centers receive. We study the 'flypaper effect' or the extent to which these directed funds have actually increased SUD treatment spending. The study sample included all VA facilities and used observational data spanning years 2002 to 2010. Data were analyzed with a fixed effects, ordinary least squares specification with monetized workload as the dependent variable and funding dedicated to SUD specialty clinics the key dependent variable, controlling for unrestricted funding. We observed different effects of dedicated SUD specialty clinic funding over the period 2002 to 2008 versus 2009 to 2010. In the earlier period, there is no evidence of a significant portion of the dedicated funding sticking to its target. In the later period, a substantial proportion--38% in 2009 and 61% in 2010--of funding dedicated to SUD specialty clinics did translate into increased medical center spending for SUD treatment. In comparison, only five cents of every dollar of unrestricted funding is spent on SUD treatment. Relative to unrestricted funding, dedicated funding for SUD treatment was much more effective in increasing workload, but only in years 2009 and 2010. The differences in those years relative to prior ones may be due to the observed management focus on SUD and SUD-related treatment in the later years. If true, this suggests that in a centrally directed healthcare organization such as the VA, funding dedicated to a service is a necessary, but not sufficient condition for increasing resources expended for that service.

  7. Quantitative sensory testing measures individual pain responses in emergency department patients

    Directory of Open Access Journals (Sweden)

    Duffy KJ

    2017-05-01

    Full Text Available Kevin J Duffy, Katharyn L Flickinger, Jeffrey T Kristan, Melissa J Repine, Alexandro Gianforcaro, Rebecca B Hasley, Saad Feroz, Jessica M Rupp, Jumana Al-Baghli, Maria L Pacella, Brian P Suffoletto, Clifton W Callaway Department of Emergency Medicine, School of Medicine, University of Pittsburgh, Pittsburgh, PA, USA Background: Refining and individualizing treatment of acute pain in the emergency department (ED is a high priority, given that painful complaints are the most common reasons for ED visits. Few tools exist to objectively measure pain perception in the ED setting. We speculated that variation in perception of fixed painful stimuli would explain individual variation in reported pain and response to treatment among ED patients. Materials and methods: In three studies, we 1 describe performance characteristics of brief quantitative sensory testing (QST in 50 healthy volunteers, 2 test effects of 10 mg oxycodone versus placebo on QST measures in 18 healthy volunteers, and 3 measure interindividual differences in nociception and treatment responses in 198 ED patients with a painful complaint during ED treatment. QST measures adapted for use in the ED included pressure sensation threshold, pressure pain threshold (PPT, pressure pain response (PPR, and cold pain tolerance (CPT tests. Results: First, all QST measures had high inter-rater reliability and test–retest reproducibility. Second, 10 mg oxycodone reduced PPR, increased PPT, and prolonged CPT. Third, baseline PPT and PPR revealed hyperalgesia in 31 (16% ED subjects relative to healthy volunteers. In 173 (88% ED subjects who completed repeat testing 30 minutes after pain treatment, PPT increased and PPR decreased (Cohen’s dz 0.10–0.19. Verbal pain scores (0–10 for the ED complaint decreased by 2.2 (95% confidence intervals [CI]: 1.9, 2.6 (Cohen’s dz 0.97 but did not covary with the changes in PPT and PPR (r=0.05–0.13. Treatment effects were greatest in ED subjects

  8. Quantitative Trait Locus and Brain Expression of HLA-DPA1 Offers Evidence of Shared Immune Alterations in Psychiatric Disorders

    Directory of Open Access Journals (Sweden)

    Ling Z. Morgan

    2016-03-01

    Full Text Available Genome-wide association studies of schizophrenia encompassing the major histocompatibility locus (MHC were highly significant following genome-wide correction. This broad region implicates many genes including the MHC complex class II. Within this interval we examined the expression of two MHC II genes (HLA-DPA1 and HLA-DRB1 in brain from individual subjects with schizophrenia (SZ, bipolar disorder (BD, major depressive disorder (MDD, and controls by differential gene expression methods. A third MHC II mRNA, CD74, was studied outside of the MHC II locus, as it interacts within the same immune complex. Exon microarrays were performed in anterior cingulate cortex (ACC in BD compared to controls, and both HLA-DPA1 and CD74 were decreased in expression in BD. The expression of HLA-DPA1 and CD74 were both reduced in hippocampus, amygdala, and dorsolateral prefrontal cortex regions in SZ and BD compared to controls by specific qPCR assay. We found several novel HLA-DPA1 mRNA variants spanning HLA-DPA1 exons 2-3-4 as suggested by exon microarrays. The intronic rs9277341 SNP was a significant cis expression quantitative trait locus (eQTL that was associated with the total expression of HLA-DPA1 in five brain regions. A biomarker study of MHC II mRNAs was conducted in SZ, BD, MDD, and control lymphoblastic cell lines (LCL by qPCR assay of 87 subjects. There was significantly decreased expression of HLA-DPA1 and CD74 in BD, and trends for reductions in SZ in LCLs. The discovery of multiple splicing variants in brain for HLA-DPA1 is important as the HLA-DPA1 gene is highly conserved, there are no reported splicing variants, and the functions in brain are unknown. Future work on the function and localization of MHC Class II proteins in brain will help to understand the role of alterations in neuropsychiatric disorders. The HLA-DPA1 eQTL is located within a large linkage disequilibrium block that has an irrefutable association with schizophrenia. Future

  9. Efficacy and toxicity in brain tumor treatment - quantitative Measurements using advanced MRI

    DEFF Research Database (Denmark)

    Ravn, Søren

    2016-01-01

    From the clinical introduction in the 1980s, MRI has grown to become an indispensable brain imaging modality, mainly due to its excellent ability to visualize soft tissues. Morphologically, T1- and T2-weighted brain tumor MRI have been part of routine diagnostic radiology for more than two decades...... with the introduction of magnets with higher field strength. Ongoing technical development has enabled a change from semiquantitative measurements to a true quantitative approach. This step is expected to have a great impact on the treatment of brain tumor patients in the future. The aim of this Ph.D. dissertation...... was to explore how different advanced MRI techniques could contribute to a higher degree of individualized treatment of brain tumor patients. The thesis is based on three studies in which advanced MRI is used to evaluate the possible role of fMRI in presurgical planning, Diffusion Tensor Imaging (DTI...

  10. Quantitative radioisotope measurement of duodenogastric reflux in patients with ulcer or gastrectomized for ulcer

    International Nuclear Information System (INIS)

    Hyoedynmaa, S.; Paeaekkoenen, A.; Laensimies, E.; Korhonen, K.; Paeaekkoenen, M.; Aukee, S.

    1985-01-01

    In this work the duodenogastric reflux was quantified as the amount of radioactivity entering the stomach after an i.v. administration of sup(99m)Tc-HIDA in ulcer patients and in patients who had undergone BI gastrectomy. The results were compared with visual evidence of gastric activity in the gamma camera images and biochemical determination of gastric bile reflux. The method is useful in quantifying the reflux if the activity is above the background activity. It allows the determination of an upper limit for the reflux when the reflux is evident visually. Only two or three images are needed for the quantitation. No correlation was found between biochemical measurements of fasting bile reflux in the stomach and radioisotopic quantification. (orig.) [de

  11. Quantitative radioisotope measurement of duodenogastric reflux in patients with ulcer or gastrectomized for ulcer

    Energy Technology Data Exchange (ETDEWEB)

    Hyoedynmaa, S.; Paeaekkoenen, A.; Laensimies, E.; Korhonen, K.; Paeaekkoenen, M.; Aukee, S.

    1985-06-01

    In this work the duodenogastric reflux was quantified as the amount of radioactivity entering the stomach after an i.v. administration of sup(99m)Tc-HIDA in ulcer patients and in patients who had undergone BI gastrectomy. The results were compared with visual evidence of gastric activity in the gamma camera images and biochemical determination of gastric bile reflux. The method is useful in quantifying the reflux if the activity is above the background activity. It allows the determination of an upper limit for the reflux when the reflux is evident visually. Only two or three images are needed for the quantitation. No correlation was found between biochemical measurements of fasting bile reflux in the stomach and radioisotopic quantification.

  12. Methods for quantitative measurement of tooth wear using the area and volume of virtual model cusps.

    Science.gov (United States)

    Kim, Soo-Hyun; Park, Young-Seok; Kim, Min-Kyoung; Kim, Sulhee; Lee, Seung-Pyo

    2018-04-01

    Clinicians must examine tooth wear to make a proper diagnosis. However, qualitative methods of measuring tooth wear have many disadvantages. Therefore, this study aimed to develop and evaluate quantitative parameters using the cusp area and volume of virtual dental models. The subjects of this study were the same virtual models that were used in our former study. The same age group classification and new tooth wear index (NTWI) scoring system were also reused. A virtual occlusal plane was generated with the highest cusp points and lowered vertically from 0.2 to 0.8 mm to create offset planes. The area and volume of each cusp was then measured and added together. In addition to the former analysis, the differential features of each cusp were analyzed. The scores of the new parameters differentiated the age and NTWI groups better than those analyzed in the former study. The Spearman ρ coefficients between the total area and the area of each cusp also showed higher scores at the levels of 0.6 mm (0.6A) and 0.8A. The mesiolingual cusp (MLC) showed a statistically significant difference ( P <0.01) from the other cusps in the paired t -test. Additionally, the MLC exhibited the highest percentage of change at 0.6A in some age and NTWI groups. Regarding the age groups, the MLC showed the highest score in groups 1 and 2. For the NTWI groups, the MLC was not significantly different in groups 3 and 4. These results support the proposal that the lingual cusp exhibits rapid wear because it serves as a functional cusp. Although this study has limitations due to its cross-sectional nature, it suggests better quantitative parameters and analytical tools for the characteristics of cusp wear.

  13. Quantitative optical microscopy: measurement of cellular biophysical features with a standard optical microscope.

    Science.gov (United States)

    Phillips, Kevin G; Baker-Groberg, Sandra M; McCarty, Owen J T

    2014-04-07

    We describe the use of a standard optical microscope to perform quantitative measurements of mass, volume, and density on cellular specimens through a combination of bright field and differential interference contrast imagery. Two primary approaches are presented: noninterferometric quantitative phase microscopy (NIQPM), to perform measurements of total cell mass and subcellular density distribution, and Hilbert transform differential interference contrast microscopy (HTDIC) to determine volume. NIQPM is based on a simplified model of wave propagation, termed the paraxial approximation, with three underlying assumptions: low numerical aperture (NA) illumination, weak scattering, and weak absorption of light by the specimen. Fortunately, unstained cellular specimens satisfy these assumptions and low NA illumination is easily achieved on commercial microscopes. HTDIC is used to obtain volumetric information from through-focus DIC imagery under high NA illumination conditions. High NA illumination enables enhanced sectioning of the specimen along the optical axis. Hilbert transform processing on the DIC image stacks greatly enhances edge detection algorithms for localization of the specimen borders in three dimensions by separating the gray values of the specimen intensity from those of the background. The primary advantages of NIQPM and HTDIC lay in their technological accessibility using "off-the-shelf" microscopes. There are two basic limitations of these methods: slow z-stack acquisition time on commercial scopes currently abrogates the investigation of phenomena faster than 1 frame/minute, and secondly, diffraction effects restrict the utility of NIQPM and HTDIC to objects from 0.2 up to 10 (NIQPM) and 20 (HTDIC) μm in diameter, respectively. Hence, the specimen and its associated time dynamics of interest must meet certain size and temporal constraints to enable the use of these methods. Excitingly, most fixed cellular specimens are readily investigated with

  14. Prognostic value of quantitative fluorodeoxyglucose measurements in newly diagnosed metastatic breast cancer

    International Nuclear Information System (INIS)

    Ulaner, Gary A; Eaton, Anne; Morris, Patrick G; Lilienstein, Joshua; Jhaveri, Komal; Patil, Sujata; Fazio, Maurizio; Larson, Steven; Hudis, Clifford A; Jochelson, Maxine S

    2013-01-01

    The aim of this study was to determine the prognostic value of quantitative fluorodeoxyglucose (FDG) measurements (maximum standardized uptake value [SUV max ], metabolic tumor volume [MTV], and total lesion glycolysis [TLG]) in patients with newly diagnosed metastatic breast cancer (MBC). An IRB-approved retrospective review was performed of patients who underwent FDG positron emission tomography (PET)/computed tomography (CT) from 1/02 to 12/08 within 60 days of diagnosis MBC. Patients with FDG-avid lesions without receiving chemotherapy in the prior 30 days were included. Target lesions in bone, lymph node (LN), liver, and lung were analyzed for SUV max , MTV, and TLG. Medical records were reviewed for patient characteristics and overall survival (OS). Cox regression was used to test associations between quantitative FDG measurements and OS. A total of 253 patients were identified with disease in bone (n = 150), LN (n = 162), liver (n = 48), and lung (n = 66) at the time of metastatic diagnosis. Higher SUV max tertile was associated with worse OS in bone metastases (highest vs. lowest tertile hazard ratio [HR] = 3.1, P < 0.01), but not in LN, liver or lung (all P > 0.1). Higher MTV tertile was associated with worse OS in LN (HR = 2.4, P < 0.01) and liver (HR = 3.0, P = 0.02) metastases, but not in bone (P = 0.22) or lung (P = 0.14). Higher TLG tertile was associated with worse OS in bone (HR = 2.2, P = 0.02), LN (HR = 2.3, P < 0.01), and liver (HR = 4.9, P < 0.01) metastases, but not in lung (P = 0.19). We conclude measures of FDG avidity are prognostic biomarkers in newly diagnosed MBC. SUV max and TLG were both predictors of survival in breast cancer patients with bone metastases. TLG may be a more informative biomarker of OS than SUV max for patients with LN and liver metastases. Measures of fluorodeoxyglucose (FDG) avidity are prognostic biomarkers in newly diagnosed metastatic breast cancer. Volumetric measurements, such as total lesion glycolysis (TLG

  15. Quantitative outcome measures for systemic sclerosis-related Microangiopathy - Reliability of image acquisition in Nailfold Capillaroscopy.

    Science.gov (United States)

    Dinsdale, Graham; Moore, Tonia; O'Leary, Neil; Berks, Michael; Roberts, Christopher; Manning, Joanne; Allen, John; Anderson, Marina; Cutolo, Maurizio; Hesselstrand, Roger; Howell, Kevin; Pizzorni, Carmen; Smith, Vanessa; Sulli, Alberto; Wildt, Marie; Taylor, Christopher; Murray, Andrea; Herrick, Ariane L

    2017-09-01

    Nailfold capillaroscopic parameters hold increasing promise as outcome measures for clinical trials in systemic sclerosis (SSc). Their inclusion as outcomes would often naturally require capillaroscopy images to be captured at several time points during any one study. Our objective was to assess repeatability of image acquisition (which has been little studied), as well as of measurement. 41 patients (26 with SSc, 15 with primary Raynaud's phenomenon) and 10 healthy controls returned for repeat high-magnification (300×) videocapillaroscopy mosaic imaging of 10 digits one week after initial imaging (as part of a larger study of reliability). Images were assessed in a random order by an expert blinded observer and 4 outcome measures extracted: (1) overall image grade and then (where possible) distal vessel locations were marked, allowing (2) vessel density (across the whole nailfold) to be calculated (3) apex width measurement and (4) giant vessel count. Intra-rater, intra-visit and intra-rater inter-visit (baseline vs. 1week) reliability were examined in 475 and 392 images respectively. A linear, mixed-effects model was used to estimate variance components, from which intra-class correlation coefficients (ICCs) were determined. Intra-visit and inter-visit reliability estimates (ICCs) were (respectively): overall image grade, 0.97 and 0.90; vessel density, 0.92 and 0.65; mean vessel width, 0.91 and 0.79; presence of giant capillary, 0.68 and 0.56. These estimates were conditional on each parameter being measurable. Within-operator image analysis and acquisition are reproducible. Quantitative nailfold capillaroscopy, at least with a single observer, provides reliable outcome measures for clinical studies including randomised controlled trials. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Developing scales measuring disorder-specific intolerance of uncertainty (DSIU) : a new perspective on transdiagnostic

    NARCIS (Netherlands)

    Thibodeau, Michel A; Carleton, R Nicholas; McEvoy, Peter M; Zvolensky, Michael J; Brandt, Charles P; Boelen, Paul A; Mahoney, Alison E J; Deacon, Brett J; Asmundson, Gordon J G

    Intolerance of uncertainty (IU) is a construct of growing prominence in literature on anxiety disorders and major depressive disorder. Existing measures of IU do not define the uncertainty that respondents perceive as distressing. To address this limitation, we developed eight scales measuring

  17. Quantitative measurement of lung density with x-ray CT and positron CT, (2). Diseased subjects

    Energy Technology Data Exchange (ETDEWEB)

    Ito, Kengo; Ito, Masatoshi; Kubota, Kazuo

    1985-05-01

    Lung density was quantitatively measured on six diseased patients with X-ray CT (XCT) and Positron CT(PCT). The findings are as follows: In the silicosis, extravascular lung density was found to be remarkably increased compared to normals (0.29gcm/sup 3/), but blood volume was in normal range. In the post-irradiated lung cancers, extravascular lung density increased in the irradiated sites compared to the non-irradiated opposite sites, and blood volume varied in each case. In a patient with chronic heart failure, blood volume decreased (0.11mlcm/sup 3/) with increased extravascular lung density (0.23gcm/sup 3/). In the chronic obstructive pulmonary disease, both extravascular lung density and blood volume decreased (0.11gcm/sup 3/ and 0.10mlcm/sup 3/ respectively). Lung density measured with XCT was constantly lower than that with PCT in all cases. But changes in the values of lung density measured, correlated well with each other. In conclusion, the method presented here may clarify the etiology of the diffuse pulmonary diseases, and be used to differentiate and grade the diseases.

  18. Limitations of quantitative photoacoustic measurements of blood oxygenation in small vessels

    International Nuclear Information System (INIS)

    Sivaramakrishnan, Mathangi; Maslov, Konstantin; Zhang, Hao F; Stoica, George; Wang, Lihong V

    2007-01-01

    We investigate the feasibility of obtaining accurate quantitative information, such as local blood oxygenation level (sO 2 ), with a spatial resolution of about 50 μm from spectral photoacoustic (PA) measurements. The optical wavelength dependence of the peak values of the PA signals is utilized to obtain the local blood oxygenation level. In our in vitro experimental models, the PA signal amplitude is found to be linearly proportional to the blood optical absorption coefficient when using ultrasonic transducers with central frequencies high enough such that the ultrasonic wavelengths are shorter than the light penetration depth into the blood vessels. For an optical wavelength in the 578-596 nm region, with a transducer central frequency that is above 25 MHz, the sensitivity and accuracy of sO 2 inversion is shown to be better than 4%. The effect of the transducer focal position on the accuracy of quantifying blood oxygenation is found to be negligible. In vivo oxygenation measurements of rat skin microvasculature yield results consistent with those from in vitro studies, although factors specific to in vivo measurements, such as the spectral dependence of tissue optical attenuation, dramatically affect the accuracy of sO 2 quantification in vivo

  19. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    International Nuclear Information System (INIS)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo

    2011-01-01

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R 2= 0.838, P 2= 0.067, P=0.316 by IRMA, and R 2= 0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients

  20. Quantitative measurement of lung density with x-ray CT and positron CT, (2)

    International Nuclear Information System (INIS)

    Ito, Kengo; Ito, Masatoshi; Kubota, Kazuo

    1985-01-01

    Lung density was quantitatively measured on six diseased patients with X-ray CT (XCT) and Positron CT(PCT). The findings are as follows: In the silicosis, extravascular lung density was found to be remarkably increased compared to normals (0.29gcm -3 ), but blood volume was in normal range. In the post-irradiated lung cancers, extravascular lung density increased in the irradiated sites compared to the non-irradiated opposite sites, and blood volume varied in each case. In a patient with chronic heart failure, blood volume decreased (0.11mlcm -3 ) with increased extravascular lung density (0.23gcm -3 ). In the chronic obstructive pulmonary disease, both extravascular lung density and blood volume decreased (0.11gcm -3 and 0.10mlcm -3 respectively). Lung density measured with XCT was constantly lower than that with PCT in all cases. But changes in the values of lung density measured, correlated well with each other. In conclusion, the method presented here may clarify the etiology of the diffuse pulmonary diseases, and be used to differentiate and grade the diseases. (author)

  1. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National Univ. Seoul (Korea, Republic of)

    2011-03-15

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R{sup 2=}0.838, P<0.001). Serum HBsAg level and serum HBV DNA copies were found to be linearly related by both methods (R{sup 2=}0.067, P=0.316 by IRMA, and R{sup 2=}0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients.

  2. Quantitative materials analysis of micro devices using absorption-based thickness measurements

    International Nuclear Information System (INIS)

    Sim, L M; Wog, B S; Spowage, A C

    2006-01-01

    Preliminary work in designing an X-ray inspection machine with the capability of providing quantitative thickness analysis based on absorption measurements has been demonstrated. This study attempts to use the gray levels data to investigate the nature and thickness of occluded features and materials within devices. The investigation focused on metallic materials essential to semiconductor and MEMS technologies such as tin, aluminium, copper, silver, iron and zinc. The materials were arranged to simulate different feature thicknesses and sample geometries. The X-ray parameters were varied in-order to modify the X-ray energy spectrum with the aim of optimising the measurement conditions for each sample. The capability of the method to resolve differences in thicknesses was found to be highly dependent on the material. The thickness resolution with aluminium was the poorest due to its low radiographic density. The thickness resolutions achievable for silver and tin were significantly better and of the order of 0.015 mm and 0.025 mm respectively. From the linear relationship between the X-ray attenuation and sample thickness established, the energy dependent linear attenuation coefficient for each material was determined for a series of specific energy spectra. A decrease in the linear attenuation coefficient was observed as the applied voltage and thickness of the material increased. The results provide a platform for the development of a novel absorption-based thickness measurement system that can be optimised for a range of industrial applications

  3. A quantitative risk assessment model to evaluate effective border control measures for rabies prevention

    Science.gov (United States)

    Weng, Hsin-Yi; Wu, Pei-I; Yang, Ping-Cheng; Tsai, Yi-Lun; Chang, Chao-Chin

    2009-01-01

    Border control is the primary method to prevent rabies emergence. This study developed a quantitative risk model incorporating stochastic processes to evaluate whether border control measures could efficiently prevent rabies introduction through importation of cats and dogs using Taiwan as an example. Both legal importation and illegal smuggling were investigated. The impacts of reduced quarantine and/or waiting period on the risk of rabies introduction were also evaluated. The results showed that Taiwan’s current animal importation policy could effectively prevent rabies introduction through legal importation of cats and dogs. The median risk of a rabid animal to penetrate current border control measures and enter Taiwan was 5.33 × 10−8 (95th percentile: 3.20 × 10−7). However, illegal smuggling may pose Taiwan to the great risk of rabies emergence. Reduction of quarantine and/or waiting period would affect the risk differently, depending on the applied assumptions, such as increased vaccination coverage, enforced custom checking, and/or change in number of legal importations. Although the changes in the estimated risk under the assumed alternatives were not substantial except for completely abolishing quarantine, the consequences of rabies introduction may yet be considered to be significant in a rabies-free area. Therefore, a comprehensive benefit-cost analysis needs to be conducted before recommending these alternative measures. PMID:19822125

  4. Validating Quantitative Measurement Using Qualitative Data: Combining Rasch Scaling and Latent Semantic Analysis in Psychiatry

    Science.gov (United States)

    Lange, Rense

    2015-02-01

    An extension of concurrent validity is proposed that uses qualitative data for the purpose of validating quantitative measures. The approach relies on Latent Semantic Analysis (LSA) which places verbal (written) statements in a high dimensional semantic space. Using data from a medical / psychiatric domain as a case study - Near Death Experiences, or NDE - we established concurrent validity by connecting NDErs qualitative (written) experiential accounts with their locations on a Rasch scalable measure of NDE intensity. Concurrent validity received strong empirical support since the variance in the Rasch measures could be predicted reliably from the coordinates of their accounts in the LSA derived semantic space (R2 = 0.33). These coordinates also predicted NDErs age with considerable precision (R2 = 0.25). Both estimates are probably artificially low due to the small available data samples (n = 588). It appears that Rasch scalability of NDE intensity is a prerequisite for these findings, as each intensity level is associated (at least probabilistically) with a well- defined pattern of item endorsements.

  5. Tracer-based laser-induced fluorescence measurement technique for quantitative fuel/air-ratio measurements in a hydrogen internal combustion engine.

    Science.gov (United States)

    Blotevogel, Thomas; Hartmann, Matthias; Rottengruber, Hermann; Leipertz, Alfred

    2008-12-10

    A measurement technique for the quantitative investigation of mixture formation processes in hydrogen internal combustion engines (ICEs) has been developed using tracer-based laser-induced fluorescence (TLIF). This technique can be employed to fired and motored engine operation. The quantitative TLIF fuel/air-ratio results have been verified by means of linear Raman scattering measurements. Exemplary results of the simultaneous investigation of mixture formation and combustion obtained at an optical accessible hydrogen ICE are shown.

  6. Direct measurement of superdiffusive energy transport in disordered granular chains.

    Science.gov (United States)

    Kim, Eunho; Martínez, Alejandro J; Phenisee, Sean E; Kevrekidis, P G; Porter, Mason A; Yang, Jinkyu

    2018-02-13

    Energy transport properties in heterogeneous materials have attracted scientific interest for more than half of a century, and they continue to offer fundamental and rich questions. One of the outstanding challenges is to extend Anderson theory for uncorrelated and fully disordered lattices in condensed-matter systems to physical settings in which additional effects compete with disorder. Here we present the first systematic experimental study of energy transport and localization properties in simultaneously disordered and nonlinear granular crystals. In line with prior theoretical studies, we observe in our experiments that disorder and nonlinearity-which individually favor energy localization-can effectively cancel each other out, resulting in the destruction of wave localization. We also show that the combined effect of disorder and nonlinearity can enable manipulation of energy transport speed in granular crystals. Specifically, we experimentally demonstrate superdiffusive transport. Furthermore, our numerical computations suggest that subdiffusive transport should be attainable by controlling the strength of the system's external precompression force.

  7. Quantitative measurement of lightning-induced electron precipitation using VLF remote sensing

    Science.gov (United States)

    Peter, William Bolton

    This dissertation examines the detection of lightning-induced energetic electron precipitation via subionospheric Very Low Frequency (VLF) remote sensing. The primary measurement tool used is a distributed set of VLF observing sites, the Holographic Array for Ionospheric/Lightning Research (HAIL), located along the eastern side of the Rocky Mountains in the Central United States. Measurements of the VLF signal perturbations indicate that 90% of the precipitation occurs over a region ˜8 degrees in latitudinal extent, with the peak of the precipitation poleward displaced ˜7 degrees from the causative discharge. A comparison of the VLF signal perturbations recorded on the HAIL array with a comprehensive model of LEP events allows for the quantitative measurement of electron precipitation and ionospheric density enhancement with unprecedented quantitative detail. The model consists of three major components: a test-particle model of gyroresonant whistler-induced electron precipitation; a Monte Carlo simulation of energy deposition into the ionosphere; and a model of VLF subionospheric signal propagation. For the two representative LEP events studied, the model calculates peak VLF amplitude and phase perturbations within a factor of three of those observed, well within the expected variability of radiation belt flux levels. The modeled precipitated energy flux (E>45 keV) peaks at ˜1 x 10-2 [ergs s-1 cm -2], resulting in a peak loss of ˜0.001% from a single flux tube at L˜2.2, consistent with previous satellite measurements of LEP events. Metrics quantifying the ionospheric density enhancement (N ILDE) and the electron precipitation (Gamma) are strongly correlated with the VLF signal perturbations calculated by the model. A conversion ratio Psi relates VLF signal amplitude perturbations (DeltaA) to the time-integrated precipitation (100-300 keV) along the VLF path (Psi=Gamma / DeltaA). The total precipitation (100-300 keV) induced by one of the representative LEP

  8. Disentangling the adult attention-deficit hyperactivity disorder endophenotype: parametric measurement of attention.

    Science.gov (United States)

    Finke, Kathrin; Schwarzkopf, Wolfgang; Müller, Ulrich; Frodl, Thomas; Müller, Hermann J; Schneider, Werner X; Engel, Rolf R; Riedel, Michael; Möller, Hans-Jürgen; Hennig-Fast, Kristina

    2011-11-01

    Attention deficit hyperactivity disorder (ADHD) persists frequently into adulthood. The decomposition of endophenotypes by means of experimental neuro-cognitive assessment has the potential to improve diagnostic assessment, evaluation of treatment response, and disentanglement of genetic and environmental influences. We assessed four parameters of attentional capacity and selectivity derived from simple psychophysical tasks (verbal report of briefly presented letter displays) and based on a "theory of visual attention." These parameters are mathematically independent, quantitative measures, and previous studies have shown that they are highly sensitive for subtle attention deficits. Potential reductions of attentional capacity, that is, of perceptual processing speed and working memory storage capacity, were assessed with a whole report paradigm. Furthermore, possible pathologies of attentional selectivity, that is, selection of task-relevant information and bias in the spatial distribution of attention, were measured with a partial report paradigm. A group of 30 unmedicated adult ADHD patients and a group of 30 demographically matched healthy controls were tested. ADHD patients showed significant reductions of working memory storage capacity of a moderate to large effect size. Perceptual processing speed, task-based, and spatial selection were unaffected. The results imply a working memory deficit as an important source of behavioral impairments. The theory of visual attention parameter working memory storage capacity might constitute a quantifiable and testable endophenotype of ADHD.

  9. Quantitative measures of meniscus extrusion predict incident radiographic knee osteoarthritis – data from the Osteoarthritis Initiative

    Science.gov (United States)

    Emmanuel, K.; Quinn, E.; Niu, J.; Guermazi, A.; Roemer, F.; Wirth, W.; Eckstein, F.; Felson, D.

    2017-01-01

    SUMMARY Objective To test the hypothesis that quantitative measures of meniscus extrusion predict incident radiographic knee osteoarthritis (KOA), prior to the advent of radiographic disease. Methods 206 knees with incident radiographic KOA (Kellgren Lawrence Grade (KLG) 0 or 1 at baseline, developing KLG 2 or greater with a definite osteophyte and joint space narrowing (JSN) grade ≥1 by year 4) were matched to 232 control knees not developing incident KOA. Manual segmentation of the central five slices of the medial and lateral meniscus was performed on coronal 3T DESS MRI and quantitative meniscus position was determined. Cases and controls were compared using conditional logistic regression adjusting for age, sex, BMI, race and clinical site. Sensitivity analyses of early (year [Y] 1/2) and late (Y3/4) incidence was performed. Results Mean medial extrusion distance was significantly greater for incident compared to non-incident knees (1.56 mean ± 1.12 mm SD vs 1.29 ± 0.99 mm; +21%, P meniscus (25.8 ± 15.8% vs 22.0 ± 13.5%; +17%, P meniscus in incident medial KOA, or for the tibial plateau coverage between incident and non-incident knees. Restricting the analysis to medial incident KOA at Y1/2 differences were attenuated, but reached significance for extrusion distance, whereas no significant differences were observed at incident KOA in Y3/4. Conclusion Greater medial meniscus extrusion predicts incident radiographic KOA. Early onset KOA showed greater differences for meniscus position between incident and non-incident knees than late onset KOA. PMID:26318658

  10. Quantitative measures of meniscus extrusion predict incident radiographic knee osteoarthritis--data from the Osteoarthritis Initiative.

    Science.gov (United States)

    Emmanuel, K; Quinn, E; Niu, J; Guermazi, A; Roemer, F; Wirth, W; Eckstein, F; Felson, D

    2016-02-01

    To test the hypothesis that quantitative measures of meniscus extrusion predict incident radiographic knee osteoarthritis (KOA), prior to the advent of radiographic disease. 206 knees with incident radiographic KOA (Kellgren Lawrence Grade (KLG) 0 or 1 at baseline, developing KLG 2 or greater with a definite osteophyte and joint space narrowing (JSN) grade ≥1 by year 4) were matched to 232 control knees not developing incident KOA. Manual segmentation of the central five slices of the medial and lateral meniscus was performed on coronal 3T DESS MRI and quantitative meniscus position was determined. Cases and controls were compared using conditional logistic regression adjusting for age, sex, BMI, race and clinical site. Sensitivity analyses of early (year [Y] 1/2) and late (Y3/4) incidence was performed. Mean medial extrusion distance was significantly greater for incident compared to non-incident knees (1.56 mean ± 1.12 mm SD vs 1.29 ± 0.99 mm; +21%, P meniscus (25.8 ± 15.8% vs 22.0 ± 13.5%; +17%, P meniscus in incident medial KOA, or for the tibial plateau coverage between incident and non-incident knees. Restricting the analysis to medial incident KOA at Y1/2 differences were attenuated, but reached significance for extrusion distance, whereas no significant differences were observed at incident KOA in Y3/4. Greater medial meniscus extrusion predicts incident radiographic KOA. Early onset KOA showed greater differences for meniscus position between incident and non-incident knees than late onset KOA. Copyright © 2015 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  11. Quantitative multi-color FRET measurements by Fourier lifetime excitation-emission matrix spectroscopy

    Science.gov (United States)

    Zhao, Ming; Huang, Run; Peng, Leilei

    2012-01-01

    Förster resonant energy transfer (FRET) is extensively used to probe macromolecular interactions and conformation changes. The established FRET lifetime analysis method measures the FRET process through its effect on the donor lifetime. In this paper we present a method that directly probes the time-resolved FRET signal with frequency domain Fourier lifetime excitation-emission matrix (FLEEM) measurements. FLEEM separates fluorescent signals by their different phonon energy pathways from excitation to emission. The FRET process generates a unique signal channel that is initiated by donor excitation but ends with acceptor emission. Time-resolved analysis of the FRET EEM channel allows direct measurements on the FRET process, unaffected by free fluorophores that might be present in the sample. Together with time-resolved analysis on non-FRET channels, i.e. donor and acceptor EEM channels, time resolved EEM analysis allows precise quantification of FRET in the presence of free fluorophores. The method is extended to three-color FRET processes, where quantification with traditional methods remains challenging because of the significantly increased complexity in the three-way FRET interactions. We demonstrate the time-resolved EEM analysis method with quantification of three-color FRET in incompletely hybridized triple-labeled DNA oligonucleotides. Quantitative measurements of the three-color FRET process in triple-labeled dsDNA are obtained in the presence of free single-labeled ssDNA and double-labeled dsDNA. The results establish a quantification method for studying multi-color FRET between multiple macromolecules in biochemical equilibrium. PMID:23187535

  12. Quantitative Evaluation of MODIS Fire Radiative Power Measurement for Global Smoke Emissions Assessment

    Science.gov (United States)

    Ichoku, Charles; Ellison, Luke

    2011-01-01

    Satellite remote sensing is providing us tremendous opportunities to measure the fire radiative energy (FRE) release rate or power (FRP) from open biomass burning, which affects many vegetated regions of the world on a seasonal basis. Knowledge of the biomass burning characteristics and emission source strengths of different (particulate and gaseous) smoke constituents is one of the principal ingredients upon which the assessment, modeling, and forecasting of their distribution and impacts depend. This knowledge can be gained through accurate measurement of FRP, which has been shown to have a direct relationship with the rates of biomass consumption and emissions of major smoke constituents. Over the last decade or so, FRP has been routinely measured from space by both the MODIS sensors aboard the polar orbiting Terra and Aqua satellites, and the SEVIRI sensor aboard the Meteosat Second Generation (MSG) geostationary satellite. During the last few years, FRP has steadily gained increasing recognition as an important parameter for facilitating the development of various scientific studies and applications relating to the quantitative characterization of biomass burning and their emissions. To establish the scientific integrity of the FRP as a stable quantity that can be measured consistently across a variety of sensors and platforms, with the potential of being utilized to develop a unified long-term climate data record of fire activity and impacts, it needs to be thoroughly evaluated, calibrated, and validated. Therefore, we are conducting a detailed analysis of the FRP products from MODIS to evaluate the uncertainties associated with them, such as those due to the effects of satellite variable observation geometry and other factors, in order to establish their error budget for use in diverse scientific research and applications. In this presentation, we will show recent results of the MODIS FRP uncertainty analysis and error mitigation solutions, and demonstrate

  13. Model-independent quantitative measurement of nanomechanical oscillator vibrations using electron-microscope linescans

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huan; Fenton, J. C.; Chiatti, O. [London Centre for Nanotechnology, University College London, 17–19 Gordon Street, London WC1H 0AH (United Kingdom); Warburton, P. A. [London Centre for Nanotechnology, University College London, 17–19 Gordon Street, London WC1H 0AH (United Kingdom); Department of Electronic and Electrical Engineering, University College London, Torrington Place, London WC1E 7JE (United Kingdom)

    2013-07-15

    Nanoscale mechanical resonators are highly sensitive devices and, therefore, for application as highly sensitive mass balances, they are potentially superior to micromachined cantilevers. The absolute measurement of nanoscale displacements of such resonators remains a challenge, however, since the optical signal reflected from a cantilever whose dimensions are sub-wavelength is at best very weak. We describe a technique for quantitative analysis and fitting of scanning-electron microscope (SEM) linescans across a cantilever resonator, involving deconvolution from the vibrating resonator profile using the stationary resonator profile. This enables determination of the absolute amplitude of nanomechanical cantilever oscillations even when the oscillation amplitude is much smaller than the cantilever width. This technique is independent of any model of secondary-electron emission from the resonator and is, therefore, applicable to resonators with arbitrary geometry and material inhomogeneity. We demonstrate the technique using focussed-ion-beam–deposited tungsten cantilevers of radius ∼60–170 nm inside a field-emission SEM, with excitation of the cantilever by a piezoelectric actuator allowing measurement of the full frequency response. Oscillation amplitudes approaching the size of the primary electron-beam can be resolved. We further show that the optimum electron-beam scan speed is determined by a compromise between deflection of the cantilever at low scan speeds and limited spatial resolution at high scan speeds. Our technique will be an important tool for use in precise characterization of nanomechanical resonator devices.

  14. Sex differences in bone marrow density measured by quantitative ultrasonometry: For 20 year old college student

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Jeong [Dept. of Radiological Technology, Daejeon Health Institute of Technology, Daejeon (Korea, Republic of)

    2017-09-15

    The purpose of this study is to compare the bone marrow density measured by quantitative ultrasonometry (QUS) between men and women. Questionnaires for general characteristics were obtained from 104 participants, and then their both calcaneus was measured by using QUS. Sex differences for bone marrow density (BMD) were analyzed by an Independent t-test using the SPSS 19.0 program. Of 104 participants, women and men were 69(66.3%) and 35(33.7%), respectively. T-value of left calcaneus was high significantly in women than that in men(0.443 vs. 0.031, p=0.161) as well as that of right calcaneus(0.555 vs. 0.049, p=0.093). T-value of right calcaneus was high than that of left calcaneus in women and men (not significant, p>0.05). T-value of both calcaneus was increasing with physical activity. T-value of calcaneus was no statistically significant with age and body mass index. The BMD of women is high significantly more than that of men, and BMD is relation with physical activity.

  15. Sex differences in bone marrow density measured by quantitative ultrasonometry: For 20 year old college student

    International Nuclear Information System (INIS)

    Lee, Won Jeong

    2017-01-01

    The purpose of this study is to compare the bone marrow density measured by quantitative ultrasonometry (QUS) between men and women. Questionnaires for general characteristics were obtained from 104 participants, and then their both calcaneus was measured by using QUS. Sex differences for bone marrow density (BMD) were analyzed by an Independent t-test using the SPSS 19.0 program. Of 104 participants, women and men were 69(66.3%) and 35(33.7%), respectively. T-value of left calcaneus was high significantly in women than that in men(0.443 vs. 0.031, p=0.161) as well as that of right calcaneus(0.555 vs. 0.049, p=0.093). T-value of right calcaneus was high than that of left calcaneus in women and men (not significant, p>0.05). T-value of both calcaneus was increasing with physical activity. T-value of calcaneus was no statistically significant with age and body mass index. The BMD of women is high significantly more than that of men, and BMD is relation with physical activity

  16. Quantitative measurement and analysis for detection and treatment planning of developmental dysplasia of the hip

    Science.gov (United States)

    Liu, Xin; Lu, Hongbing; Chen, Hanyong; Zhao, Li; Shi, Zhengxing; Liang, Zhengrong

    2009-02-01

    Developmental dysplasia of the hip is a congenital hip joint malformation affecting the proximal femurs and acetabulum that are subluxatable, dislocatable, and dislocated. Conventionally, physicians made diagnoses and treatments only based on findings from two-dimensional (2D) images by manually calculating clinic parameters. However, anatomical complexity of the disease and the limitation of current standard procedures make accurate diagnosis quite difficultly. In this study, we developed a system that provides quantitative measurement of 3D clinical indexes based on computed tomography (CT) images. To extract bone structure from surrounding tissues more accurately, the system firstly segments the bone using a knowledge-based fuzzy clustering method, which is formulated by modifying the objective function of the standard fuzzy c-means algorithm with additive adaptation penalty. The second part of the system calculates automatically the clinical indexes, which are extended from 2D to 3D for accurate description of spatial relationship between femurs and acetabulum. To evaluate the system performance, experimental study based on 22 patients with unilateral or bilateral affected hip was performed. The results of 3D acetabulum index (AI) automatically provided by the system were validated by comparison with 2D results measured by surgeons manually. The correlation between the two results was found to be 0.622 (p<0.01).

  17. The quantitative measurement of organizational culture in health care: a review of the available instruments.

    Science.gov (United States)

    Scott, Tim; Mannion, Russell; Davies, Huw; Marshall, Martin

    2003-06-01

    To review the quantitative instruments available to health service researchers who want to measure culture and cultural change. A literature search was conducted using Medline, Cinahl, Helmis, Psychlit, Dhdata, and the database of the King's Fund in London for articles published up to June 2001, using the phrase "organizational culture." In addition, all citations and the gray literature were reviewed and advice was sought from experts in the field to identify instruments not found on the electronic databases. The search focused on instruments used to quantify culture with a track record, or potential for use, in health care settings. For each instrument we examined the cultural dimensions addressed, the number of items for each questionnaire, the measurement scale adopted, examples of studies that had used the tool, the scientific properties of the instrument, and its strengths and limitations. Thirteen instruments were found that satisfied our inclusion criteria, of which nine have a track record in studies involving health care organizations. The instruments varied considerably in terms of their grounding in theory, format, length, scope, and scientific properties. A range of instruments with differing characteristics are available to researchers interested in organizational culture, all of which have limitations in terms of their scope, ease of use, or scientific properties. The choice of instrument should be determined by how organizational culture is conceptualized by the research team, the purpose of the investigation, intended use of the results, and availability of resources.

  18. Quantitative measurement of natural radioactivity in some roofing tile materials used in upper Egypt

    International Nuclear Information System (INIS)

    Uosif, M. A. M.

    2013-01-01

    The quantitative measurement of radionuclides ( 226 Ra, 232 Th and 40 K) in some roofing tile materials (granite, alabaster, marble, traditional and advanced ceramic) used in Upper Egypt is presented in this paper. Measurements were done by using gamma spectrometry (NaI (Tl) 3'' x 3''). The values of concentration of natural radionuclides were in the following ranges: 12-78.9 Bq kg -1 for 226 Ra, 8.4-113.1 Bq kg -1 for 232 Th and 94.9-509 Bq kg -1 for 40 K. The activity concentration index (I), the specific dose rates indoors (D . ) and the annual effective dose (D E ) due to gamma radiation were calculated for each investigated sample. The lowest value of I is 0.19 for alabaster, while the highest one is 0.88 for traditional and advanced ceramic. The ranges of D E are between 0.03 and 0.13 mSv, it is below the maximal permitted values, so that the examined materials could be used as roofing tiles in the construction of new buildings. (authors)

  19. Quantitative measurement of local elasticity of SiOx film by atomic force acoustic microscopy

    International Nuclear Information System (INIS)

    Cun-Fu, He; Gai-Mei, Zhang; Bin, Wu

    2010-01-01

    In this paper the elastic properties of SiO x film are investigated quantitatively for local fixed point and qualitatively for overall area by atomic force acoustic microscopy (AFAM) in which the sample is vibrated at the ultrasonic frequency while the sample surface is touched and scanned with the tip contacting the sample respectively for fixed point and continuous measurements. The SiO x films on the silicon wafers are prepared by the plasma enhanced chemical vapour deposition (PECVD). The local contact stiffness of the tip-SiO x film is calculated from the contact resonance spectrum measured with the atomic force acoustic microscopy. Using the reference approach, indentation modulus of SiO x film for fixed point is obtained. The images of cantilever amplitude are also visualized and analysed when the SiO x surface is excited at a fixed frequency. The results show that the acoustic amplitude images can reflect the elastic properties of the sample. (classical areas of phenomenology)

  20. Automatic and quantitative measurement of collagen gel contraction using model-guided segmentation

    Science.gov (United States)

    Chen, Hsin-Chen; Yang, Tai-Hua; Thoreson, Andrew R.; Zhao, Chunfeng; Amadio, Peter C.; Sun, Yung-Nien; Su, Fong-Chin; An, Kai-Nan

    2013-08-01

    Quantitative measurement of collagen gel contraction plays a critical role in the field of tissue engineering because it provides spatial-temporal assessment (e.g., changes of gel area and diameter during the contraction process) reflecting the cell behavior and tissue material properties. So far the assessment of collagen gels relies on manual segmentation, which is time-consuming and suffers from serious intra- and inter-observer variability. In this study, we propose an automatic method combining various image processing techniques to resolve these problems. The proposed method first detects the maximal feasible contraction range of circular references (e.g., culture dish) and avoids the interference of irrelevant objects in the given image. Then, a three-step color conversion strategy is applied to normalize and enhance the contrast between the gel and background. We subsequently introduce a deformable circular model which utilizes regional intensity contrast and circular shape constraint to locate the gel boundary. An adaptive weighting scheme was employed to coordinate the model behavior, so that the proposed system can overcome variations of gel boundary appearances at different contraction stages. Two measurements of collagen gels (i.e., area and diameter) can readily be obtained based on the segmentation results. Experimental results, including 120 gel images for accuracy validation, showed high agreement between the proposed method and manual segmentation with an average dice similarity coefficient larger than 0.95. The results also demonstrated obvious improvement in gel contours obtained by the proposed method over two popular, generic segmentation methods.

  1. Quantitative measurements in laser-induced plasmas using optical probing. Final report

    International Nuclear Information System (INIS)

    Sweeney, D.W.

    1981-01-01

    Optical probing of laser induced plasmas can be used to quantitatively reconstruct electron number densities and magnetic fields. Numerical techniques for extracting quantitative information from the experimental data are described. A computer simulation of optical probing is used to determine the quantitative information that can be reasonably extracted from real experimental interferometric systems to reconstruct electron number density distributions. An example of a reconstructed interferogram shows a steepened electron distribution due to radiation pressure effects

  2. Reliability of Reagent Strips for Semi-quantitative Measurement of Glucosuria in a Neonatal Intensive Care Setting

    Directory of Open Access Journals (Sweden)

    Jolita Bekhof

    2014-12-01

    Conclusion: The reliability of the semi-quantitative measurement of glucosuria in newborn infants using reagent strips is good, even under the conditions of a NICU. Changes in the rating of reagent strips of more than one category are most likely to be beyond measurement error.

  3. Quantitatively accurate activity measurements with a dedicated cardiac SPECT camera: Physical phantom experiments

    Energy Technology Data Exchange (ETDEWEB)

    Pourmoghaddas, Amir, E-mail: apour@ottawaheart.ca; Wells, R. Glenn [Physics Department, Carleton University, Ottawa, Ontario K1S 5B6, Canada and Cardiology, The University of Ottawa Heart Institute, Ottawa, Ontario K1Y4W7 (Canada)

    2016-01-15

    Purpose: Recently, there has been increased interest in dedicated cardiac single photon emission computed tomography (SPECT) scanners with pinhole collimation and improved detector technology due to their improved count sensitivity and resolution over traditional parallel-hole cameras. With traditional cameras, energy-based approaches are often used in the clinic for scatter compensation because they are fast and easily implemented. Some of the cardiac cameras use cadmium-zinc-telluride (CZT) detectors which can complicate the use of energy-based scatter correction (SC) due to the low-energy tail—an increased number of unscattered photons detected with reduced energy. Modified energy-based scatter correction methods can be implemented, but their level of accuracy is unclear. In this study, the authors validated by physical phantom experiments the quantitative accuracy and reproducibility of easily implemented correction techniques applied to {sup 99m}Tc myocardial imaging with a CZT-detector-based gamma camera with multiple heads, each with a single-pinhole collimator. Methods: Activity in the cardiac compartment of an Anthropomorphic Torso phantom (Data Spectrum Corporation) was measured through 15 {sup 99m}Tc-SPECT acquisitions. The ratio of activity concentrations in organ compartments resembled a clinical {sup 99m}Tc-sestamibi scan and was kept consistent across all experiments (1.2:1 heart to liver and 1.5:1 heart to lung). Two background activity levels were considered: no activity (cold) and an activity concentration 1/10th of the heart (hot). A plastic “lesion” was placed inside of the septal wall of the myocardial insert to simulate the presence of a region without tracer uptake and contrast in this lesion was calculated for all images. The true net activity in each compartment was measured with a dose calibrator (CRC-25R, Capintec, Inc.). A 10 min SPECT image was acquired using a dedicated cardiac camera with CZT detectors (Discovery NM530c, GE

  4. Questionnaire-based person trip visualization and its integration to quantitative measurements in Myanmar

    Science.gov (United States)

    Kimijiama, S.; Nagai, M.

    2016-06-01

    With telecommunication development in Myanmar, person trip survey is supposed to shift from conversational questionnaire to GPS survey. Integration of both historical questionnaire data to GPS survey and visualizing them are very important to evaluate chronological trip changes with socio-economic and environmental events. The objectives of this paper are to: (a) visualize questionnaire-based person trip data, (b) compare the errors between questionnaire and GPS data sets with respect to sex and age and (c) assess the trip behaviour in time-series. Totally, 345 individual respondents were selected through random stratification to assess person trip using a questionnaire and GPS survey for each. Conversion of trip information such as a destination from the questionnaires was conducted by using GIS. The results show that errors between the two data sets in the number of trips, total trip distance and total trip duration are 25.5%, 33.2% and 37.2%, respectively. The smaller errors are found among working-age females mainly employed with the project-related activities generated by foreign investment. The trip distant was yearly increased. The study concluded that visualization of questionnaire-based person trip data and integrating them to current quantitative measurements are very useful to explore historical trip changes and understand impacts from socio-economic events.

  5. Bone mineral density changes during pregnancy in actively exercising women as measured by quantitative ultrasound.

    Science.gov (United States)

    To, William W K; Wong, Margaret W N

    2012-08-01

    To evaluate whether bone mineral density (BMD) changes in women engaged in active exercises during pregnancy would be different from non-exercising women. Consecutive patients with singleton pregnancies who were engaged in active exercise training during pregnancy were prospectively recruited over a period of 6 months. Quantitative USG measurements of the os calcis BMD were performed at 14-20 weeks and at 36-38 weeks. These patients were compared to a control cohort of non-exercising low-risk women. A total of 24 physically active women undergoing active physical training of over 10 h per week at 20 weeks gestation and beyond (mean 13.1 h, SD 3.3) were compared to 94 non-exercising low-risk women. A marginal fall in BMD of 0.015 g/cm(2) (SD 0.034) was demonstrable from early to late gestation in the exercising women, which was significantly lower than that of non-exercising women (0.041 g/cm(2); SD 0.042; p = 0.005). Logistic regression models confirmed that active exercises in pregnancy were significantly associated with the absence of or less BMD loss in pregnancy. In women actively engaged in physical training during pregnancy, the physiological fall in BMD during pregnancy was apparently less compared to those who did not regularly exercise.

  6. 3D OCT imaging in clinical settings: toward quantitative measurements of retinal structures

    Science.gov (United States)

    Zawadzki, Robert J.; Fuller, Alfred R.; Zhao, Mingtao; Wiley, David F.; Choi, Stacey S.; Bower, Bradley A.; Hamann, Bernd; Izatt, Joseph A.; Werner, John S.

    2006-02-01

    The acquisition speed of current FD-OCT (Fourier Domain - Optical Coherence Tomography) instruments allows rapid screening of three-dimensional (3D) volumes of human retinas in clinical settings. To take advantage of this ability requires software used by physicians to be capable of displaying and accessing volumetric data as well as supporting post processing in order to access important quantitative information such as thickness maps and segmented volumes. We describe our clinical FD-OCT system used to acquire 3D data from the human retina over the macula and optic nerve head. B-scans are registered to remove motion artifacts and post-processed with customized 3D visualization and analysis software. Our analysis software includes standard 3D visualization techniques along with a machine learning support vector machine (SVM) algorithm that allows a user to semi-automatically segment different retinal structures and layers. Our program makes possible measurements of the retinal layer thickness as well as volumes of structures of interest, despite the presence of noise and structural deformations associated with retinal pathology. Our software has been tested successfully in clinical settings for its efficacy in assessing 3D retinal structures in healthy as well as diseased cases. Our tool facilitates diagnosis and treatment monitoring of retinal diseases.

  7. Quantitative diffusion and swelling kinetic measurements using large-angle interferometric refractometry.

    Science.gov (United States)

    Saunders, John E; Chen, Hao; Brauer, Chris; Clayton, McGregor; Chen, Weijian; Barnes, Jack A; Loock, Hans-Peter

    2015-12-07

    The uptake and release of sorbates into films and coatings is typically accompanied by changes of the films' refractive index and thickness. We provide a comprehensive model to calculate the concentration of the sorbate from the average refractive index and the film thickness, and validate the model experimentally. The mass fraction of the analyte partitioned into a film is described quantitatively by the Lorentz-Lorenz equation and the Clausius-Mosotti equation. To validate the model, the uptake kinetics of water and other solvents into SU-8 films (d = 40-45 μm) were explored. Large-angle interferometric refractometry measurements can be used to characterize films that are between 15 μm to 150 μm thick and, Fourier analysis, is used to determine independently the thickness, the average refractive index and the refractive index at the film-substrate interface at one-second time intervals. From these values the mass fraction of water in SU-8 was calculated. The kinetics were best described by two independent uptake processes having different rates. Each process followed one-dimensional Fickian diffusion kinetics with diffusion coefficients for water into SU-8 photoresist film of 5.67 × 10(-9) cm(2) s(-1) and 61.2 × 10(-9) cm(2) s(-1).

  8. Quantitative measurements of localized density variations in cylindrical tablets using X-ray microtomography.

    Science.gov (United States)

    Busignies, Virginie; Leclerc, Bernard; Porion, Patrice; Evesque, Pierre; Couarraze, Guy; Tchoreloff, Pierre

    2006-08-01

    Direct compaction is a complex process that results in a density distribution inside the tablets which is often heterogeneous. Therefore, the density variations may affect the compact properties. A quantitative analysis of this phenomenon is still lacking. Recently, X-ray microtomography has been successfully used in pharmaceutical development to study qualitatively the impact of tablet shape and break-line in the density of pharmaceutical tablets. In this study, we evaluate the density profile in microcrystalline cellulose (Vivapur 12) compacts obtained at different mean porosity (ranging from 7.7% to 33.5%) using X-ray tomography technique. First, the validity of the Beer-Lambert law is studied. Then, density calibration is performed and density maps of cylindrical tablets are obtained and visualized using a process with colour-scale calibration plot which is explained. As expected, important heterogeneity in density is observed and quantified. The higher densities in peripheral region were particularly investigated and appraised in regard to the lower densities observed in the middle of the tablet. The results also underlined that in the case of pharmaceutical tablets, it is important to differentiate the mechanical properties representative of the total volume tablet and the mechanical properties that only characterize the tablet surface like the Brinell hardness measurements.

  9. A mass spectrometry-based assay for improved quantitative measurements of efflux pump inhibition.

    Directory of Open Access Journals (Sweden)

    Adam R Brown

    Full Text Available Bacterial efflux pumps are active transport proteins responsible for resistance to selected biocides and antibiotics. It has been shown that production of efflux pumps is up-regulated in a number of highly pathogenic bacteria, including methicillin resistant Staphylococcus aureus. Thus, the identification of new bacterial efflux pump inhibitors is a topic of great interest. Existing assays to evaluate efflux pump inhibitory activity rely on fluorescence by an efflux pump substrate. When employing these assays to evaluate efflux pump inhibitory activity of plant extracts and some purified compounds, we observed severe optical interference that gave rise to false negative results. To circumvent this problem, a new mass spectrometry-based method was developed for the quantitative measurement of bacterial efflux pump inhibition. The assay was employed to evaluate efflux pump inhibitory activity of a crude extract of the botanical Hydrastis Canadensis, and to compare the efflux pump inhibitory activity of several pure flavonoids. The flavonoid quercetin, which appeared to be completely inactive with a fluorescence-based method, showed an IC50 value of 75 μg/mL with the new method. The other flavonoids evaluated (apigenin, kaempferol, rhamnetin, luteolin, myricetin, were also active, with IC50 values ranging from 19 μg/mL to 75 μg/mL. The assay described herein could be useful in future screening efforts to identify efflux pump inhibitors, particularly in situations where optical interference precludes the application of methods that rely on fluorescence.

  10. Measuring parent time scarcity and fatigue as barriers to meal planning and preparation: quantitative scale development.

    Science.gov (United States)

    Storfer-Isser, Amy; Musher-Eizenman, Dara

    2013-03-01

    To examine the psychometric properties of 9 quantitative items that assess time scarcity and fatigue as parent barriers to planning and preparing meals for their children. A convenience sample of 342 parents of children aged 2-6 years completed a 20-minute online survey. Exploratory factor analysis was used to examine the factor structure and create summary scales. Internal consistency reliability and measures of construct and concurrent validity were assessed. Two scales were created based on the factor analysis: time and energy for meals and meal planning. Preliminary evidence suggests that both scales are reliable and valid. The time and energy for meals and meal planning scales can be completed quickly by busy and tired parents. As many children do not eat nutritious diets, a better understanding of the barriers that parents face is critical and may help inform interventions tailored to the needs of tired, busy parents. Copyright © 2013 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  11. A new quantitative approach to measure perceived work-related stress in Italian employees.

    Science.gov (United States)

    Cevenini, Gabriele; Fratini, Ilaria; Gambassi, Roberto

    2012-09-01

    We propose a method for a reliable quantitative measure of subjectively perceived occupational stress applicable in any company to enhance occupational safety and psychosocial health, to enable precise prevention policies and intervention and to improve work quality and efficiency. A suitable questionnaire was telephonically administered to a stratified sample of the whole Italian population of employees. Combined multivariate statistical methods, including principal component, cluster and discriminant analyses, were used to identify risk factors and to design a causal model for understanding work-related stress. The model explained the causal links of stress through employee perception of imbalance between job demands and resources for responding appropriately, by supplying a reliable U-shaped nonlinear stress index, expressed in terms of values of human systolic arterial pressure. Low, intermediate and high values indicated demotivation (or inefficiency), well-being and distress, respectively. Costs for stress-dependent productivity shortcomings were estimated to about 3.7% of national income from employment. The method identified useful structured information able to supply a simple and precise interpretation of employees' well-being and stress risk. Results could be compared with estimated national benchmarks to enable targeted intervention strategies to protect the health and safety of workers, and to reduce unproductive costs for firms.

  12. Quantitative measurement of brightness from living cells in the presence of photodepletion.

    Directory of Open Access Journals (Sweden)

    Kwang-Ho Hur

    Full Text Available The brightness of fluorescently labeled proteins provides an excellent marker for identifying protein interactions in living cells. Quantitative interpretation of brightness, however, hinges on a detailed understanding of the processes that affect the signal fluctuation of the fluorescent label. Here, we focus on the cumulative influence of photobleaching on brightness measurements in cells. Photobleaching within the finite volume of the cell leads to a depletion of the population of fluorescently labeled proteins with time. The process of photodepletion reduces the fluorescence signal which biases the analysis of brightness data. Our data show that even small reductions in the signal can introduce significant bias into the analysis of the data. We develop a model that quantifies the bias and introduce an analysis method that accurately determines brightness in the presence of photodepletion as verified by experiments with mammalian and yeast cells. In addition, photodepletion experiments with the fluorescent protein EGFP reveal the presence of a photoconversion process, which leads to a marked decrease in the brightness of the EGFP protein. We also identify conditions where the effect of EGFP's photoconversion on brightness experiments can be safely ignored.

  13. Extracting quantitative measures from EAP: a small clinical study using BFOR.

    Science.gov (United States)

    Hosseinbor, A Pasha; Chung, Moo K; Wu, Yu-Chien; Fleming, John O; Field, Aaron S; Alexander, Andrew L

    2012-01-01

    The ensemble average propagator (EAP) describes the 3D average diffusion process of water molecules, capturing both its radial and angular contents, and hence providing rich information about complex tissue microstructure properties. Bessel Fourier orientation reconstruction (BFOR) is one of several analytical, non-Cartesian EAP reconstruction schemes employing multiple shell acquisitions that have recently been proposed. Such modeling bases have not yet been fully exploited in the extraction of rotationally invariant q-space indices that describe the degree of diffusion anisotropy/restrictivity. Such quantitative measures include the zero-displacement probability (P(o)), mean squared displacement (MSD), q-space inverse variance (QIV), and generalized fractional anisotropy (GFA), and all are simply scalar features of the EAP. In this study, a general relationship between MSD and q-space diffusion signal is derived and an EAP-based definition of GFA is introduced. A significant part of the paper is dedicated to utilizing BFOR in a clinical dataset, comprised of 5 multiple sclerosis (MS) patients and 4 healthy controls, to estimate P(o), MSD, QIV, and GFA of corpus callosum, and specifically, to see if such indices can detect changes between normal appearing white matter (NAWM) and healthy white matter (WM). Although the sample size is small, this study is a proof of concept that can be extended to larger sample sizes in the future.

  14. Genetic and environmental determinants of violence risk in psychotic disorders: a multivariate quantitative genetic study of 1.8 million Swedish twins and siblings.

    Science.gov (United States)

    Sariaslan, A; Larsson, H; Fazel, S

    2016-09-01

    Patients diagnosed with psychotic disorders (for example, schizophrenia and bipolar disorder) have elevated risks of committing violent acts, particularly if they are comorbid with substance misuse. Despite recent insights from quantitative and molecular genetic studies demonstrating considerable pleiotropy in the genetic architecture of these phenotypes, there is currently a lack of large-scale studies that have specifically examined the aetiological links between psychotic disorders and violence. Using a sample of all Swedish individuals born between 1958 and 1989 (n=3 332 101), we identified a total of 923 259 twin-sibling pairs. Patients were identified using the National Patient Register using validated algorithms based on International Classification of Diseases (ICD) 8-10. Univariate quantitative genetic models revealed that all phenotypes (schizophrenia, bipolar disorder, substance misuse, and violent crime) were highly heritable (h(2)=53-71%). Multivariate models further revealed that schizophrenia was a stronger predictor of violence (r=0.32; 95% confidence interval: 0.30-0.33) than bipolar disorder (r=0.23; 0.21-0.25), and large proportions (51-67%) of these phenotypic correlations were explained by genetic factors shared between each disorder, substance misuse, and violence. Importantly, we found that genetic influences that were unrelated to substance misuse explained approximately a fifth (21%; 20-22%) of the correlation with violent criminality in bipolar disorder but none of the same correlation in schizophrenia (Pbipolar disordergenetically similar phenotypes as the latter sources may include aetiologically important clues. Clinically, these findings underline the importance of assessing risk of different phenotypes together and integrating interventions for psychiatric disorders, substance misuse, and violence.

  15. Towards a Quantitative Performance Measurement Framework to Assess the Impact of Geographic Information Standards

    Science.gov (United States)

    Vandenbroucke, D.; Van Orshoven, J.; Vancauwenberghe, G.

    2012-12-01

    Over the last decennia, the use of Geographic Information (GI) has gained importance, in public as well as in private sector. But even if many spatial data and related information exist, data sets are scattered over many organizations and departments. In practice it remains difficult to find the spatial data sets needed, and to access, obtain and prepare them for using in applications. Therefore Spatial Data Infrastructures (SDI) haven been developed to enhance the access, the use and sharing of GI. SDIs consist of a set of technological and non-technological components to reach this goal. Since the nineties many SDI initiatives saw light. Ultimately, all these initiatives aim to enhance the flow of spatial data between organizations (users as well as producers) involved in intra- and inter-organizational and even cross-country business processes. However, the flow of information and its re-use in different business processes requires technical and semantic interoperability: the first should guarantee that system components can interoperate and use the data, while the second should guarantee that data content is understood by all users in the same way. GI-standards within the SDI are necessary to make this happen. However, it is not known if this is realized in practice. Therefore the objective of the research is to develop a quantitative framework to assess the impact of GI-standards on the performance of business processes. For that purpose, indicators are defined and tested in several cases throughout Europe. The proposed research will build upon previous work carried out in the SPATIALIST project. It analyzed the impact of different technological and non-technological factors on the SDI-performance of business processes (Dessers et al., 2011). The current research aims to apply quantitative performance measurement techniques - which are frequently used to measure performance of production processes (Anupindi et al., 2005). Key to reach the research objectives

  16. Measuring Social Communication Behaviors as a Treatment Endpoint in Individuals with Autism Spectrum Disorder

    Science.gov (United States)

    Anagnostou, Evdokia; Jones, Nancy; Huerta, Marisela; Halladay, Alycia K.; Wang, Paul; Scahill, Lawrence; Horrigan, Joseph P.; Kasari, Connie; Lord, Cathy; Choi, Dennis; Sullivan, Katherine; Dawson, Geraldine

    2015-01-01

    Social communication impairments are a core deficit in autism spectrum disorder. Social communication deficit is also an early indicator of autism spectrum disorder and a factor in long-term outcomes. Thus, this symptom domain represents a critical treatment target. Identifying reliable and valid outcome measures for social communication across a…

  17. Depression and Its Measurement in Verbal Adolescents and Adults with Autism Spectrum Disorder

    Science.gov (United States)

    Gotham, Katherine; Unruh, Kathryn; Lord, Catherine

    2015-01-01

    In a sample of 50 verbally fluent adolescents and adults with autism spectrum disorders (age: 16-31 years; verbal IQ: 72-140), we examined the pattern of response and associations between scores on common measures of depressive symptoms, participant characteristics, and clinical diagnosis of depressive disorders. Beck Depression Inventory--Second…

  18. Does Self-Citation Influence Quantitative Measures of Research Productivity Among Academic Oral and Maxillofacial Surgeons?

    Science.gov (United States)

    Susarla, Srinivas M; Swanson, Edward W; Lopez, Joseph; Peacock, Zachary S; Dodson, Thomas B

    2015-10-01

    Quantitative measures of research productivity depend on the citation frequency of a publication. Citation-based metrics, such as the h-index (total number of publications h that have at least h citations), can be susceptible to self-citation, resulting in an inflated measure of research productivity. The purpose of the present study was to estimate the effect of self-citation on the h-index among academic oral and maxillofacial surgeons (OMSs). The present study was a cross-sectional study of full-time academic OMSs in the United States. The predictor variable was the frequency of self-citation. The primary outcome of interest was the h-index. Other study variables included demographic factors and citation metrics. Descriptive, bivariate, and regression statistics were computed. The study sample consisted of 325 full-time academic OMSs. Most surgeons were men (88.3%); approximately 40% had medical degrees. The study subjects had an average of 23.5 ± 37.1 publications. The mean number of self-citations was 15 + 56. The sample's mean h-index was 6.6 ± 7.6 and was associated with self-citation (r = 0.71, P citations. After adjusting for PhD degree, total number of publications, and academic rank, an increasing self-citation rate influenced the h-index (r = 0.006, P citations were more likely to have their h-index influenced by self-citation. Self-citation among full-time academic OMSs does not substantially affect the h-index. Surgeons in the top quartile of self-citation rates are more likely to influence their h-index. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Quantitative Assay of Pu-239 and Pu-240 by Neutron Transmission Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, E

    1971-04-15

    A method for quantitative assay of 239Pu and 240Pu has been tested at the reactor R1 in Stockholm. The method makes use of a fast chopper to measure the neutron transmission through a sample around the main resonances of these two isotopes - at 0.296 eV in 239Pu and at 1.056 eV in 240Pu. The transmission data measured are then combined with the known resonance cross sections to give the content of the isotopes. The method is nondestructive, i.e., one can use fuel pins as samples, even highly irradiated ones. A time-of-flight spectrometer of moderate capacity, like our fast chopper, is sufficient as the resonances are located at low energy. Altogether five samples have been used in the tests of the method. The results have been compared with mass spectrometer values. This comparison came out quite well for 239Pu whereas the chopper results for 240Pu were more than 10 per cent higher than the mass spectrometer results. This large deviation might be due to errors in the resonance cross section for 240Pu used in the analysis of the transmission data from the chopper. The best possible accuracy for a 15-hour run with our equipment is +- 1 per cent for 239Pu and +- 2 per cent for 240Pu, obtained for thick samples - about 3 x 1020 atoms per cm2 for each isotope. The accuracy corresponds to 68 per cent confidence level and does not include any contribution from the uncertainty in the resonance cross section

  20. Sacroiliac Joint/Sacrum Uptake Ratio Measured by Quantitative Sacroiliac Joint Scintigraphy

    International Nuclear Information System (INIS)

    Lee, Young Yiul; Park, Seon Yang; Lee, Myung Chul; Choi, Sang Jae; Cho, Bo Youn; Choe, Kang Won; Koh, Chang Soon

    1982-01-01

    To evaluate the diagnostic usefulness and significance of quantitative sacroiliac joint scintigraphy in the assessment of sacroiliitis, we measured Sacroiliac Joint/Sacrum Uptake Ratio (SIS Ratio) by region of interest (ROI) method using 99m Tc-methylene diphosphonate. The observed results were as follows:1) Using ROI method, the SIS ratios for the control group of 65 persons were 1.05±0.08 (left) and 1.06±0.07 (right) which were narrower in range than those of slice method (mean±S.D.) 2) The effects of age, gender and laterality on SIS ratio were not significant. 3) In left side, one of 6 patients with rheumatoid arthritis had SIS ratio in excess of 2 standard deviation of normal control group, and remainder had SIS ratios within normal limit. In right side, 3 patients had SIS ratios in excess of 2 standard deviation of normal control group, and remainder, within normal limit. 4) In both sacroiliac joint, 2 of 3 patients having sacroiliitis clinically with Reiter's syndrome whose pelvis A-P X-ray findings showed normal had high SIS ratios (left/right; 1.31/1.69, 1.90/1.80), but SIS ratio of one patient who bad no evidence of sacroiliitis clinically was within normal limit. 5) In 6 patients with ankylosing spondylitis in both sacroiliac joints, q whose pelvis A-P X-ray findings showed severe sclerotic change of sacroiliac pints had SIS ratio within normal limit or below that of normal control group, and SIS ratios of 2 patients whose pelvis A-P X-ray findings showed were increased. 6) 4 of 5 patients with low back pain of which cause could not be evaluated clinically and radiologically had SIS ratios in excess of that of normal control group. It would be concluded the quantitative sacroiliac joint scintigraphy is useful and sensitive screening method in the diagnosis as well as in the assessment clinical activity of sacroiliitis.

  1. Effect of medical cannabis on thermal quantitative measurements of pain in patients with Parkinson's disease.

    Science.gov (United States)

    Shohet, A; Khlebtovsky, A; Roizen, N; Roditi, Y; Djaldetti, R

    2017-03-01

    Cannabis can alleviate pain of various etiologies. This study assessed the effect of cannabis on motor symptoms and pain parameters in patients with Parkinson's disease (PD). Twenty patients with PD who were licensed to use cannabis underwent evaluation before and 30 min after cannabis consumption and again after long-term use. Motor function was assessed with the Unified PD Rating scale (UPDRS) by two raters, one blinded. Pain was assessed with the Pain Rating Index (PRI) and Visual Analogue Scale (VAS) of the short-form McGill Pain Questionnaire. Thermal quantitative sensory testing (QST) was performed in 18 patients. The two consecutive QST measurements were validated in 12 cannabis-naïve patients with PD. There was a significant decrease from baseline to 30 min after cannabis consumption in mean motor UPDRS score (38.1 ± 18 to 30.4 ± 15.6, p patients who consumed cannabis by vaporizer rather than smoking (19.5 ± 5.2 to 15.6 ± 8.7 °C, p = 0.02). After long-term (median 14 weeks) exposure, mean heat pain threshold decreased significantly in the more affected limb in all treated patients (43.6 ± 3.5 to 40.9 ± 3.3 °C, p = 0.05) and in cannabis smokers (43.7 ± 3.6 to 40.3 ± 2.5 °C, p = 0.008). Cannabis improved motor scores and pain symptoms in PD patients, together with a dissociate effect on heat and cold pain thresholds. Peripheral and central pathways are probably modulated by cannabis. Quantitative sensory test results are significantly altered following cannabis consumption in patients with PD. Cannabis probably acts on pain in PD via peripheral and central pathways. © 2016 European Pain Federation - EFIC®.

  2. Quantitative Method to Measure Thermal Conductivity of One-Dimensional Nanostructures Based on Scanning Thermal Wave Microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Park, Kyung Bae; Chung, Jae Hun; Hwang, Gwang Seok; Jung, Eui Han; Kwon, Oh Myoung [Korea University, Seoul (Korea, Republic of)

    2014-12-15

    We present a method to quantitatively measure the thermal conductivity of one-dimensional nanostructures by utilizing scanning thermal wave microscopy (STWM) at a nanoscale spatial resolution. In this paper, we explain the principle for measuring the thermal diffusivity of one-dimensional nanostructures using STWM and the theoretical analysis procedure for quantifying the thermal diffusivity. The SWTM measurement method obtains the thermal conductivity by measuring the thermal diffusivity, which has only a phase lag relative to the distance corresponding to the transferred thermal wave. It is not affected by the thermal contact resistances between the heat source and nanostructure and between the nanostructure and probe. Thus, the heat flux applied to the nanostructure is accurately obtained. The proposed method provides a very simple and quantitative measurement relative to conventional measurement techniques.

  3. No objectively measured sleep disturbances in children with attention-deficit/hyperactivity disorder.

    Science.gov (United States)

    Bergwerff, Catharina E; Luman, Marjolein; Oosterlaan, Jaap

    2016-10-01

    The main goal of this study was to gain more insight into sleep disturbances in children with attention-deficit/hyperactivity disorder, using objective measures of sleep quality and quantity. The evidence for sleep problems in children with attention-deficit/hyperactivity disorder thus far is inconsistent, which might be explained by confounding influences of comorbid internalizing and externalizing problems and low socio-economic status. We therefore investigated the mediating and moderating role of these factors in the association between attention-deficit/hyperactivity disorder and sleep problems. To control for the effects of stimulant medication use, all participants were tested free of medication. Sixty-three children with attention-deficit/hyperactivity disorder and 61 typically developing children, aged 6-13 years, participated. Sleep was monitored for one to three school nights using actigraphy. Parent and teacher questionnaires assessed symptoms of attention-deficit/hyperactivity disorder, internalizing behaviour, oppositional defiant disorder and conduct disorder. Results showed no differences between the attention-deficit/hyperactivity disorder and typically developing group in any sleep parameter. Within the attention-deficit/hyperactivity disorder group, severity of attention-deficit/hyperactivity disorder symptoms was not related to sleep quality or quantity. Moderation analyses in the attention-deficit/hyperactivity disorder group showed an interaction effect between attention-deficit/hyperactivity disorder symptoms and internalizing and externalizing behaviour on total sleep time, time in bed and average sleep bout duration. The results of our study suggest that having attention-deficit/hyperactivity disorder is not a risk factor for sleep problems. Internalizing and externalizing behaviour moderate the association between attention-deficit/hyperactivity disorder and sleep, indicating a complex interplay between psychiatric symptoms and sleep.

  4. The utility of quantitative electroencephalography and Integrated Visual and Auditory Continuous Performance Test as auxiliary tools for the Attention Deficit Hyperactivity Disorder diagnosis.

    Science.gov (United States)

    Kim, JunWon; Lee, YoungSik; Han, DougHyun; Min, KyungJoon; Kim, DoHyun; Lee, ChangWon

    2015-03-01

    This study investigated the clinical utility of quantitative electroencephalography (QEEG) and the Integrated Visual and Auditory Continuous Performance Test (IVA+CPT) as auxiliary tools for assessing Attention Deficit Hyperactivity Disorder (ADHD). All of 157 subjects were assessed using the Korean version of the Diagnostic Interview Schedule for Children Version IV (DISC-IV). We measured EGG absolute power in 21 channels and conducted IVA+CPT. We analyzed QEEG according to the Hz range: delta (1-4Hz), theta (4-8Hz), slow alpha (8-10Hz), fast alpha (10-13.5Hz), and beta (13.5-30Hz). To remove artifacts, independent component analysis was conducted (ICA), and the tester confirmed the results again. All of the IVA+CPT quotients showed significant differences between the ADHD and control groups. The ADHD group showed significantly increased delta and theta activity compared with the control group. The z-scores of theta were negatively correlated with the scores of IVA+CPT in ADHD combined type, and those of beta were positively correlated. IVA+CPT and QEEG significantly discriminated between ADHD and control groups. The commission error of IVA+CPT showed an accuracy of 82.1%, and the omission error of IVA+CPT showed an accuracy of 78.6%. The IVA+CPT and QEEG are expected to be valuable tools for aiding ADHD diagnosis accurately. Copyright © 2014 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Conjugate whole-body scanning system for quantitative measurement of organ distribution in vivo

    International Nuclear Information System (INIS)

    Tsui, B.M.W.; Chen, C.T.; Yasillo, N.J.; Ortega, C.J.; Charleston, D.B.; Lathrop, K.A.

    1979-01-01

    The determination of accurate, quantitative, biokinetic distribution of an internally dispersed radionuclide in humans is important in making realistic radiation absorbed dose estimates, studying biochemical transformations in health and disease, and developing clinical procedures indicative of abnormal functions. In order to collect these data, a whole-body imaging system is required which provides both adequate spatial resolution and some means of absolute quantitation. Based on these considerations, a new whole-body scanning system has been designed and constructed that employs the conjugate counting technique. The conjugate whole-body scanning system provides an efficient and accurate means of collecting absolute quantitative organ distribution data of radioactivity in vivo

  6. Failure to Integrate Quantitative Measurement Methods of Ocular Inflammation Hampers Clinical Practice and Trials on New Therapies for Posterior Uveitis.

    Science.gov (United States)

    Herbort, Carl P; Tugal-Tutkun, Ilknur; Neri, Piergiorgio; Pavésio, Carlos; Onal, Sumru; LeHoang, Phuc

    2017-05-01

    Uveitis is one of the fields in ophthalmology where a tremendous evolution took place in the past 25 years. Not only did we gain access to more efficient, more targeted, and better tolerated therapies, but also in parallel precise and quantitative measurement methods developed allowing the clinician to evaluate these therapies and adjust therapeutic intervention with a high degree of precision. Objective and quantitative measurement of the global level of intraocular inflammation became possible for most inflammatory diseases with direct or spill-over anterior chamber inflammation, thanks to laser flare photometry. The amount of retinal inflammation could be quantified by using fluorescein angiography to score retinal angiographic signs. Indocyanine green angiography gave imaging insight into the hitherto inaccessible choroidal compartment, rendering possible the quantification of choroiditis by scoring indocyanine green angiographic signs. Optical coherence tomography has enabled measurement and objective monitoring of retinal and choroidal thickness. This multimodal quantitative appraisal of intraocular inflammation represents an exquisite security in monitoring uveitis. What is enigmatic, however, is the slow pace with which these improvements are integrated in some areas. What is even more difficult to understand is the fact that clinical trials to assess new therapeutic agents still mostly rely on subjective parameters such as clinical evaluation of vitreous haze as a main endpoint; whereas a whole array of precise, quantitative, and objective modalities are available for the design of clinical studies. The scope of this work was to review the quantitative investigations that improved the management of uveitis in the past 2-3 decades.

  7. Whole Word Measures in Bilingual Children with Speech Sound Disorders

    Science.gov (United States)

    Burrows, Lauren; Goldstein, Brian A.

    2010-01-01

    Phonological acquisition traditionally has been measured using constructs that focus on segments rather than the whole words. Findings from recent research have suggested whole-word productions be evaluated using measures such as phonological mean length of utterance (pMLU) and the proportion of whole-word proximity (PWP). These measures have been…

  8. Quantitative measurement of water diffusion lifetimes at a protein/DNA interface by NMR

    International Nuclear Information System (INIS)

    Gruschus, James M.; Ferretti, James A.

    2001-01-01

    Hydration site lifetimes of slowly diffusing water molecules at the protein/DNA interface of the vnd/NK-2 homeodomain DNA complex were determined using novel three-dimensional NMR techniques. The lifetimes were calculated using the ratios of ROE and NOE cross-relaxation rates between the water and the protein backbone and side chain amides. This calculation of the lifetimes is based on a model of the spectral density function of the water-protein interaction consisting of three timescales of motion: fast vibrational/rotational motion, diffusion into/out of the hydration site, and overall macromolecular tumbling. The lifetimes measured ranged from approximately 400 ps to more than 5 ns, and nearly all the slowly diffusing water molecules detected lie at the protein/DNA interface. A quantitative analysis of relayed water cross-relaxation indicated that even at very short mixing times, 5 ms for ROESY and 12 ms for NOESY, relay of magnetization can make a small but detectable contribution to the measured rates. The temperature dependences of the NOE rates were measured to help discriminate direct dipolar cross-relaxation from chemical exchange. Comparison with several X-ray structures of homeodomain/DNA complexes reveals a strong correspondence between water molecules in conserved locations and the slowly diffusing water molecules detected by NMR. A homology model based on the X-ray structures was created to visualize the conserved water molecules detected at the vnd/NK-2 homeodomain DNA interface. Two chains of water molecules are seen at the right and left sides of the major groove, adjacent to the third helix of the homeodomain. Two water-mediated hydrogen bond bridges spanning the protein/DNA interface are present in the model, one between the backbone of Phe8 and a DNA phosphate, and one between the side chain of Asn51 and a DNA phosphate. The hydrogen bond bridge between Asn51 and the DNA might be especially important since the DNA contact made by the invariant

  9. Quantitative measurement and visualization of biofilm O 2 consumption rates in membrane filtration systems

    KAUST Repository

    Prest, Emmanuelle I E C; Staal, Marc J.; Kü hl, Michael; van Loosdrecht, Mark C.M.; Vrouwenvelder, Johannes S.

    2012-01-01

    There is a strong need for techniques enabling direct assessment of biological activity of biofouling in membrane filtration systems. Here we present a new quantitative and non-destructive method for mapping O 2 dynamics in biofilms during

  10. Introducing Anisotropic Minkowski Functionals and Quantitative Anisotropy Measures for Local Structure Analysis in Biomedical Imaging

    Science.gov (United States)

    Wismüller, Axel; De, Titas; Lochmüller, Eva; Eckstein, Felix; Nagarajan, Mahesh B.

    2017-01-01

    The ability of Minkowski Functionals to characterize local structure in different biological tissue types has been demonstrated in a variety of medical image processing tasks. We introduce anisotropic Minkowski Functionals (AMFs) as a novel variant that captures the inherent anisotropy of the underlying gray-level structures. To quantify the anisotropy characterized by our approach, we further introduce a method to compute a quantitative measure motivated by a technique utilized in MR diffusion tensor imaging, namely fractional anisotropy. We showcase the applicability of our method in the research context of characterizing the local structure properties of trabecular bone micro-architecture in the proximal femur as visualized on multi-detector CT. To this end, AMFs were computed locally for each pixel of ROIs extracted from the head, neck and trochanter regions. Fractional anisotropy was then used to quantify the local anisotropy of the trabecular structures found in these ROIs and to compare its distribution in different anatomical regions. Our results suggest a significantly greater concentration of anisotropic trabecular structures in the head and neck regions when compared to the trochanter region (p < 10−4). We also evaluated the ability of such AMFs to predict bone strength in the femoral head of proximal femur specimens obtained from 50 donors. Our results suggest that such AMFs, when used in conjunction with multi-regression models, can outperform more conventional features such as BMD in predicting failure load. We conclude that such anisotropic Minkowski Functionals can capture valuable information regarding directional attributes of local structure, which may be useful in a wide scope of biomedical imaging applications. PMID:29170580

  11. CTXA hip--an extension of classical DXA measurements using quantitative CT.

    Science.gov (United States)

    Cann, Christopher E; Adams, Judith E; Brown, J Keenan; Brett, Alan D

    2014-01-01

    Bone mineral density (BMD) estimates for the proximal femur using Dual Energy X-ray Absorptiometry (DXA) are currently considered the standard for making a diagnosis of osteoporosis in an individual patient using BMD alone. We have compared BMD results from a commercial Quantitative CT (QCT) BMD analysis system, "CTXA Hip", which provides clinical data for the proximal femur, to results from DXA. We have also used CTXA Hip to determine cortical and trabecular contributions to total BMD. Sixty-nine patients were scanned using 3D QCT and DXA. CTXA Hip BMD measurements for Total Hip and Femoral Neck were compared to DXA results. Twenty-two women were scanned at 0, 1, 2 years and CTXA Hip and DXA results analyzed for long-term reproducibility. Long-term reproducibility calculated as root-mean-square averages of SDs in vivo was 0.012 g/cm2 (CV = 1.8%) for CTXA Total Hip and 0.011 g/cm2 (CV = 2.0%) for CTXA Femoral Neck compared to 0.014 g/cm2 (CV = 2.0%) and 0.016 g/cm2 (CV = 2.7%), respectively, for DXA. The correlation of Total Hip BMD CTXA vs. DXA was R = 0.97 and for Femoral Neck was R = 0.95 (SEE 0.044 g/cm2 in both cases). Cortical bone comprised 62±5% (mean ± SD) of total hipbone mass in osteoporotic women. CTXA Hip provides substantially the same clinical information as conventional DXA and in addition provides estimates of BMD in separate cortical and trabecular bone compartments, which may be useful in evaluation of bone strength.

  12. CTXA hip--an extension of classical DXA measurements using quantitative CT.

    Directory of Open Access Journals (Sweden)

    Christopher E Cann

    Full Text Available Bone mineral density (BMD estimates for the proximal femur using Dual Energy X-ray Absorptiometry (DXA are currently considered the standard for making a diagnosis of osteoporosis in an individual patient using BMD alone. We have compared BMD results from a commercial Quantitative CT (QCT BMD analysis system, "CTXA Hip", which provides clinical data for the proximal femur, to results from DXA. We have also used CTXA Hip to determine cortical and trabecular contributions to total BMD. Sixty-nine patients were scanned using 3D QCT and DXA. CTXA Hip BMD measurements for Total Hip and Femoral Neck were compared to DXA results. Twenty-two women were scanned at 0, 1, 2 years and CTXA Hip and DXA results analyzed for long-term reproducibility. Long-term reproducibility calculated as root-mean-square averages of SDs in vivo was 0.012 g/cm2 (CV = 1.8% for CTXA Total Hip and 0.011 g/cm2 (CV = 2.0% for CTXA Femoral Neck compared to 0.014 g/cm2 (CV = 2.0% and 0.016 g/cm2 (CV = 2.7%, respectively, for DXA. The correlation of Total Hip BMD CTXA vs. DXA was R = 0.97 and for Femoral Neck was R = 0.95 (SEE 0.044 g/cm2 in both cases. Cortical bone comprised 62±5% (mean ± SD of total hipbone mass in osteoporotic women. CTXA Hip provides substantially the same clinical information as conventional DXA and in addition provides estimates of BMD in separate cortical and trabecular bone compartments, which may be useful in evaluation of bone strength.

  13. Quantitative measurement of cerebral oxygen extraction fraction using MRI in patients with MELAS.

    Directory of Open Access Journals (Sweden)

    Lei Yu

    Full Text Available OBJECTIVE: To quantify the cerebral OEF at different phases of stroke-like episodes in patients with mitochondrial myopathy, encephalopathy, lactic acidosis, and stroke-like episodes (MELAS by using MRI. METHODS: We recruited 32 patients with MELAS confirmed by gene analysis. Conventional MRI scanning, as well as functional MRI including arterial spin labeling and oxygen extraction fraction imaging, was undertaken to obtain the pathological and metabolic information of the brains at different stages of stroke-like episodes in patients. A total of 16 MRI examinations at the acute and subacute phase and 19 examinations at the interictal phase were performed. In addition, 24 healthy volunteers were recruited for control subjects. Six regions of interest were placed in the anterior, middle, and posterior parts of the bilateral hemispheres to measure the OEF of the brain or the lesions. RESULTS: OEF was reduced significantly in brains of patients at both the acute and subacute phase (0.266 ± 0.026 and at the interictal phase (0.295 ± 0.009, compared with normal controls (0.316 ± 0.025. In the brains at the acute and subacute phase of the episode, 13 ROIs were prescribed on the stroke-like lesions, which showed decreased OEF compared with the contralateral spared brain regions. Increased blood flow was revealed in the stroke-like lesions at the acute and subacute phase, which was confined to the lesions. CONCLUSION: MRI can quantitatively show changes in OEF at different phases of stroke-like episodes. The utilization of oxygen in the brain seems to be reduced more severely after the onset of episodes in MELAS, especially for those brain tissues involved in the episodes.

  14. Bacteroides gingivalis-Actinomyces viscosus cohesive interactions as measured by a quantitative binding assay

    International Nuclear Information System (INIS)

    Schwarz, S.; Ellen, R.P.; Grove, D.A.

    1987-01-01

    There is limited evidence, mostly indirect, to suggest that the adherence of Bacteroides gingivalis to teeth may be enhanced by the presence of gram-positive dental plaque bacteria like Actinomyces viscosus. The purpose of this study was to carry out direct quantitative assessments of the cohesion of B gingivalis and A. viscosus by using an in vitro assay modeled on the natural sequence in which these two species colonize the teeth. The assay allowed comparisons to be made of the adherence of 3 H-labeled B. gingivalis 2561 and 381 to saliva-coated hydroxyapatite beads (S-HA) and A. viscosus WVU627- or T14V-coated S-HA (actinobeads) in equilibrium and kinetics binding studies. A series of preliminary binding studies with 3H-labeled A. viscosus and parallel studies by scanning electron microscopy with unlabeled A. viscosus were conducted to establish a protocol by which actinobeads suitable for subsequent Bacteroides adherence experiments could be prepared. By scanning electron microscopy, the actinobeads had only small gaps of exposed S-HA between essentially irreversibly bound A. viscosus cells. Furthermore, B. gingivalis cells appeared to bind preferentially to the Actinomyces cells instead of the exposed S-HA. B. gingivalis binding to both S-HA and actinobeads was saturable with at least 2 X 10(9) to 3 X 10(9) cells per ml, and equilibrium with saturating concentrations was reached within 10 to 20 min. B. gingivalis always bound in greater numbers to the actinobeads than to S-HA. These findings provide direct measurements supporting the concept that cohesion with dental plaque bacteria like A. viscosus may foster the establishment of B. gingivalis on teeth by enhancing its adherence

  15. Absolute choline concentration measured by quantitative proton MR spectroscopy correlates with cell density in meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Yue, Qiang [University of Tsukuba, Department of Neurosurgery, Institute of Clinical Medicine, Tsukuba Science City, Ibaraki (Japan)]|[West China Hospital of Sichuan University, Huaxi MR Research Center, Department of Radiology, Chengdu (China); Shibata, Yasushi; Kawamura, Hiraku; Matsumura, Akira [University of Tsukuba, Department of Neurosurgery, Institute of Clinical Medicine, Tsukuba Science City, Ibaraki (Japan); Isobe, Tomonori [Kitasato University, Department of Medical Technology, School of Allied Health Sciences, Minato, Tokyo (Japan); Anno, Izumi [University of Tsukuba, Department of Radiology, Institute of Clinical Medicine, Tsukuba, Ibaraki (Japan); Gong, Qi-Yong [West China Hospital of Sichuan University, Huaxi MR Research Center, Department of Radiology, Chengdu (China)]|[University of Liverpool, Division of Medical Imaging, Faculty of Medicine, Liverpool (United Kingdom)

    2009-01-15

    This study was aimed to investigate the relationship between quantitative proton magnetic resonance spectroscopy (1H-MRS) and pathological changes in meningioma. Twenty-two meningioma cases underwent single voxel 1H-MRS (point-resolved spectroscopy sequence, repetition time/echo time = 2,000 ms/68, 136, 272 ms). Absolute choline (Cho) concentration was calculated using tissue water as the internal reference and corrected according to intra-voxel cystic/necrotic parts. Pathological specimens were stained with MIB-1 antibody to measure cell density and proliferation index. Correlation analysis was performed between absolute Cho concentration and cell density and MIB-1 labeled proliferation index. Average Cho concentration of all meningiomas before correction was 2.95 {+-} 0.86 mmol/kg wet weight. It was increased to 3.23 {+-} 1.15 mmol/kg wet weight after correction. Average cell density of all meningiomas was 333 {+-} 119 cells/HPF, and average proliferation index was 2.93 {+-} 5.72%. A linear, positive correlation between cell density and Cho concentration was observed (r = 0.650, P = 0.001). After correction of Cho concentration, the correlation became more significant (r = 0.737, P < 0.001). However, no significant correlation between Cho concentration and proliferation index was found. There seemed to be a positive correlation trend after correction of Cho concentration but did not reach significant level. Absolute Cho concentration, especially Cho concentration corrected according to intra-voxel cystic/necrotic parts, reflects cell density of meningioma. (orig.)

  16. The correlative analysis between CBF measured by SPECT and Chinese reading test in childhood reading disorder

    International Nuclear Information System (INIS)

    Wu Yonggang; Su Jianzhi; He Jianjun; Yang Zhiwei; Liu Guofeng

    2002-01-01

    Objective: To investigate changes of cerebral blood flow (CBF) and its association with Chinese reading skill diagnostic test (CRSDT) in childhood reading disorder (RD). Methods: In 25 RD children and 20 age-matched control subjects, the authors quantitatively determined CBF and regional cerebral blood flow (rCBF) with SPECT using the non-blood-withdrew method. The authors studied the correlation between the CBF and the total raw scores by CRSDT. Results: CBF in case group was (38.87 +- 3.77) ml·100 g -1 ·min -1 and was significantly lower than that in control group [43.65 +- 2.64) mL·100 g -1 ·min -1 (P < 0.01)]. These reduction in CBF correlated with the total raw scores by CRSDT. Conclusion: These results suggest the children with reading disorder have CBF reduction and SPECT is useful for evaluation of cerebral functioning in reading disorder children

  17. Review of quantitative phase-digital holographic microscopy: promising novel imaging technique to resolve neuronal network activity and identify cellular biomarkers of psychiatric disorders

    KAUST Repository

    Marquet, Pierre

    2014-09-22

    Quantitative phase microscopy (QPM) has recently emerged as a new powerful quantitative imaging technique well suited to noninvasively explore a transparent specimen with a nanometric axial sensitivity. In this review, we expose the recent developments of quantitative phase-digital holographic microscopy (QP-DHM). Quantitative phase-digital holographic microscopy (QP-DHM) represents an important and efficient quantitative phase method to explore cell structure and dynamics. In a second part, the most relevant QPM applications in the field of cell biology are summarized. A particular emphasis is placed on the original biological information, which can be derived from the quantitative phase signal. In a third part, recent applications obtained, with QP-DHM in the field of cellular neuroscience, namely the possibility to optically resolve neuronal network activity and spine dynamics, are presented. Furthermore, potential applications of QPM related to psychiatry through the identification of new and original cell biomarkers that, when combined with a range of other biomarkers, could significantly contribute to the determination of high risk developmental trajectories for psychiatric disorders, are discussed.

  18. Quantitative nitric oxide measurements by means of laser-induced fluorescence in a heavy-duty Diesel engine

    NARCIS (Netherlands)

    Verbiezen, K.; Vliet, van A.P.; Klein-Douwel, R.J.H.; Ganippa, L.C.; Bougie, H.J.T.; Meerts, W.L.; Dam, N.J.; Meulen, ter J.J.

    2005-01-01

    Quantitative in-cylinder laser-induced fluorescence measurements ofnitric oxide in a heavy-duty Diesel engine are presented. Special attention is paid to experimental techniques to assess the attenuation of the laser beam and the fluorescence signal by the cylinder contents.This attenuation can be

  19. Quantitative estimation of the influence of external vibrations on the measurement error of a coriolis mass-flow meter

    NARCIS (Netherlands)

    van de Ridder, Bert; Hakvoort, Wouter; van Dijk, Johannes; Lötters, Joost Conrad; de Boer, Andries; Dimitrovova, Z.; de Almeida, J.R.

    2013-01-01

    In this paper the quantitative influence of external vibrations on the measurement value of a Coriolis Mass-Flow Meter for low flows is investigated, with the eventual goal to reduce the influence of vibrations. Model results are compared with experimental results to improve the knowledge on how

  20. Quantitative determination of localized tissue oxygen concentration in vivo by two-photon excitation phosphorescence lifetime measurements

    NARCIS (Netherlands)

    Mik, Egbert G.; van Leeuwen, Ton G.; Raat, Nicolaas J.; Ince, Can

    2004-01-01

    This study describes the use of two-photon excitation phosphorescence lifetime measurements for quantitative oxygen determination in vivo. Doubling the excitation wavelength of Pd-porphyrin from visible light to the infrared allows for deeper tissue penetration and a more precise and confined

  1. Genetic influences on attention deficit hyperactivity disorder symptoms from age 2 to 3: A quantitative and molecular genetic investigation

    Directory of Open Access Journals (Sweden)

    Saudino Kimberly J

    2010-12-01

    Full Text Available Abstract Background A twin study design was used to assess the degree to which additive genetic variance influences ADHD symptom scores across two ages during infancy. A further objective in the study was to observe whether genetic association with a number of candidate markers reflects results from the quantitative genetic analysis. Method We have studied 312 twin pairs at two time-points, age 2 and age 3. A composite measure of ADHD symptoms from two parent-rating scales: The Child Behavior Checklist/1.5 - 5 years (CBCL hyperactivity scale and the Revised Rutter Parent Scale for Preschool Children (RRPSPC was used for both quantitative and molecular genetic analyses. Results At ages 2 and 3 ADHD symptoms are highly heritable (h2 = 0.79 and 0.78, respectively with a high level of genetic stability across these ages. However, we also observe a significant level of genetic change from age 2 to age 3. There are modest influences of non-shared environment at each age independently (e2 = 0.22 and 0.21, respectively, with these influences being largely age-specific. In addition, we find modest association signals in DAT1 and NET1 at both ages, along with suggestive specific effects of 5-HTT and DRD4 at age 3. Conclusions ADHD symptoms are heritable at ages 2 and 3. Additive genetic variance is largely shared across these ages, although there are significant new effects emerging at age 3. Results from our genetic association analysis reflect these levels of stability and change and, more generally, suggest a requirement for consideration of age-specific genotypic effects in future molecular studies.

  2. GENETIC AND MORPHOAGRONOMIC DIVERSITY OF Passiflora spp. BASED ON QUANTITATIVE MEASUREMENTS OF FLOWERS AND FRUITS

    Directory of Open Access Journals (Sweden)

    JAMILE DA SILVA OLIVEIRA

    Full Text Available ABSTRACT The aim of this study was to characterize Passiflora spp. accessions and its genetic diversity based on quantitative morphological descriptors of flowers and fruits. The study was conducted at Embrapa Cerrados, Planaltina-DF. Fifteen Passiflora spp. accessions were characterized using 14 quantitative morphological descriptors. Genetic distances among accessions were estimated based on Mahalanobis’ generalized distance. Cluster analysis via dendrogram and graphic dispersion was analyzed. The relative contribution of characters for accession divergence was also calculated. The morphoagronomic characterization based on quantitative descriptors of flowers and fruits contributed to the differentiation of Passiflora spp. accessions, serving as an important tool for variability quantification. This information is useful to perform Passiflora spp. characterization and genetic diversity studies.

  3. Use of dual energy X-ray absorptiometry, the trabecular bone score and quantitative computed tomography in the evaluation of chronic kidney disease-mineral and bone disorders.

    Science.gov (United States)

    Pocock, Nicholas

    2017-03-01

    In subjects with chronic kidney disease (CKD) who suffer a minimal trauma fracture, the problem is to differentiate between osteoporosis and the various forms of renal bone disease associated with CKD-mineral and bone disorder. This problem is exacerbated by the fact that renal osteodystrophy may coexist with osteoporosis. The World Health Organization's bone mineral density (BMD) criteria for osteopenia ( -2.5 < T-score < -1.0) and osteoporosis (a T-score ≤ -2.5) may be used in patients with CKD stages 1-3. In CKD stages 4-5, BMD by dual-energy X-ray absorptiometry (DXA) is less predictive and may underestimate fracture risk. The development of absolute fracture risk (AFR) algorithms, such as FRAX® and the Garvan absolute fracture risk calculator, to predict risk of fracture over a given time (usually 10 years) aims to incorporate non-BMD risk factors into the clinical assessment. FRAX® has been shown to be useful to assess fracture risk in CKD but may underestimate fracture risk in advanced CKD. The trabecular bone score is a measure of grey scale homogeneity obtained from spine DXA, which correlates to trabecular microarchitecture and is an independent risk factor for fracture. Recent data demonstrate the potential utility of the trabecular bone score adjustment of AFR through the FRAX® algorithm in subjects with CKD. Parameters of bone microarchitecture using peripheral quantitative computed tomography (pQCT) or high-resolution pQCT are also able to discriminate fracture status in subjects with CKD. However, there are at present no convincing data that the addition of pQCT or high-resolution pQCT parameters to DXA BMD improves fracture discrimination. More advanced estimates of bone strength derived from measurements of micro-architecture, by QCT-derived finite element analysis may be incorporated into AFR algorithms in the future. © 2017 Asian Pacific Society of Nephrology.

  4. Quantitative assessment of myocardial blood flow by measurement of fractional myocardial uptake of 201Tl

    International Nuclear Information System (INIS)

    Yonekura, Yoshiharu; Ishii, Yasushi; Torizuka, Kanji; Kadota, Kazunori; Kambara, Hirofumi

    1980-01-01

    Fractional Myocardial uptake of 201 Tl was measured for the quantitative assessment of myocardial blood flow in coronary artery disease (CAD). 10 normals and 28 CAD, 7 of which have less than 50% stenosis (CAD I) and 21 of which have more than 50% stenosis (CAD II) in the proximal portion of coronary arteries, were studied at rest and with submaximal exercise loading by bicycle ergometer. After intravenous injection of 201 Tl, its rapid transport process was recorded during the initial 5 minutes by a scintillation camera and a minicomputer. Total injected dosage (T) was obtained from the counts of the entire chest region during the initial passage of the tracer through the heart and lung. Myocardial uptake (M) was counted with the same geometry from the subsequent accumulation within the myocardial region with subtraction of the background activities in the upper mediastinal region (B). The fractional myocardial uptake of 201 Tl ((M-B)/T) is assumed to be proportional to the fractional myocardial blood flow to cardiac output (MBF/CO) according to the indicator fractionation principle. The average value of MBF/CO at rest in CAD (4.11 +- 1.12%) was significantly greater than in normals (3.36 +- 0.49%), which may be caused by an increased left ventricular mass in CAD. Change rate of MBF/CO on the exercise loading was significantly less in CAD I (1.36 +- 0.14) and in CAD II (1.11 +- 0.21) than in normals (1.75 +- 0.11). MBF/CO increased proportionally to the increment of the double product of heart rate and systolic blood pressure by exercise loading in normals, whereas it didn't in CAD. The sensitivity of this method was superior to the stress electrocardiogram and the stress myocardial perfusion imaging, not only in CAD II but also in CAD I. This result indicated that this type of global assessment of the myocardial reserve capacity is valuable in addition to the simple stress myocardial perfusion imaging. (author)

  5. Gold Nanoparticle Labeling Based ICP-MS Detection/Measurement of Bacteria, and Their Quantitative Photothermal Destruction

    Science.gov (United States)

    Lin, Yunfeng

    2015-01-01

    Bacteria such as Salmonella and E. coli present a great challenge in public health care in today’s society. Protection of public safety against bacterial contamination and rapid diagnosis of infection require simple and fast assays for the detection and elimination of bacterial pathogens. After utilizing Salmonella DT104 as an example bacterial strain for our investigation, we report a rapid and sensitive assay for the qualitative and quantitative detection of bacteria by using antibody affinity binding, popcorn shaped gold nanoparticle (GNPOPs) labeling, surfance enchanced Raman spectroscopy (SERS), and inductively coupled plasma mass spectrometry (ICP-MS) detection. For qualitative analysis, our assay can detect Salmonella within 10 min by Raman spectroscopy; for quantitative analysis, our assay has the ability to measure as few as 100 Salmonella DT104 in a 1 mL sample (100 CFU/mL) within 40 min. Based on the quantitative detection, we investigated the quantitative destruction of Salmonella DT104, and the assay’s photothermal efficiency in order to reduce the amount of GNPOPs in the assay to ultimately to eliminate any potential side effects/toxicity to the surrounding cells in vivo. Results suggest that our assay may serve as a promising candidate for qualitative and quantitative detection and elimination of a variety of bacterial pathogens. PMID:26417447

  6. Dominance in Domestic Dogs : A Quantitative Analysis of Its Behavioural Measures

    NARCIS (Netherlands)

    van der Borg, Joanne A M; Schilder, Matthijs B H; Vinke, Claudia M; de Vries, Han

    2015-01-01

    A dominance hierarchy is an important feature of the social organisation of group living animals. Although formal and/or agonistic dominance has been found in captive wolves and free-ranging dogs, applicability of the dominance concept in domestic dogs is highly debated, and quantitative data are

  7. The TAS-20 more likely measures negative affects rather than alexithymia itself in patients with major depression, panic disorder, eating disorders and substance use disorders.

    Science.gov (United States)

    Marchesi, Carlo; Ossola, Paolo; Tonna, Matteo; De Panfilis, Chiara

    2014-05-01

    This study evaluates whether the difference in Toronto Alexithymia Scale-20 item (TAS-20) between patients with major depression (MD), panic disorder (PD), eating disorders (ED), and substance use disorders (SUD) and healthy controls persisted after controlling for the severity of anxiety and depression. Thirty-eight patients with MD, 58 with PD, 52 with ED, and 30 with SUD and 78 healthy controls (C) completed the TAS-20, the Hamilton Rating Scale for Anxiety (Ham-A), the Hamilton Rating Scale for Depression (Ham-D). The differences in TAS-20 scores observed between patient groups, regardless of the type of their disorders, and controls disappeared after controlling for the effect of anxiety and depression severity. In contrast, the differences in severity of anxiety and depression between patients and controls were still present, after excluding the effect of alexithymic levels. Our data suggest that alexithymic levels, as measured by the TAS-20, are modulated by the severity of symptoms, supporting the view that alexithymia can represent a state phenomenon in patients with MD, PD, ED and SUD, because the TAS-20 seems overly sensitive to a general distress syndrome, and it is more likely to measure negative affects rather than alexithymia itself. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Semiquantitative and quantitative measurements for EDXRF in elemental chemical composition of pigments

    International Nuclear Information System (INIS)

    Costa, Elizabeth Cristina Soares da

    2005-02-01

    X-Ray fluorescence technique is largely used in the characterization of art and archaeological objects for restoration and conservation, allowing a multi-elemental, simultaneous and non destructive analysis. In this work it was used a portable XRF equipment of XRF that consists of a 238 Pu source ( 13,6 and 17,2 keV; 95 mCi) and a SI-PIN detector coupled to a 8 k multichannel analyser. The results were collected by a palmtop computer and later analysed in a PC, through the program AXIL-QXAS. The acquisition time for each measurement was 500 s. The measurements were accomplished in a wood sculpture (Santa Luzia image, number 164) from the collection of the Museu de Etnologia da Universidade de Sao Paulo (MAE-USP), in the following regions: (STL1) inferior side of the wood base exposed without finishing, (STL2) frontal inferior base of the pedestal (dark blue) (STL3), inferior part of the frontal dress (gold), (STL4) medium part of the dress (clear blue) (STL5) mantle (red), (STL6) back central lock of the hair in the backs (black), (STL7) right cheek (flesh-coloured) and (STL8) mantle (gold). The elements found in the STL1 region were: Al, Ca, Fe and a high concentration of Zn. In the region STL2 were found Al, C, Fe, Zn and the key element Cu. In the region STL3 - Ca, Zn and the key element Au. In the region STL4 it was found Zn and the key element Cu. In the region STL5 the key element S and Hg. In the region STL6 were found Fe, Ca, S and Hg. In the region STL 7 were found Al, Cu, Hg and Zn. In the region STL8 were found Ca, Al and Au, with high concentration. It was concluded that the possible pigments would be: STL2 and STL4 - CuCO 3 . Cu(OH) 2 + ZnO; STL3 and STL8 - Au; STL5 - HgS, STL6 - HgS mixed with other oxides, possibly of Fe and Mn, and STL 7 - HgS + ZnO. Standard samples of wood painted with pigments of the colors white, blue, red, rose, flesh color and green were also made. Through the XRF method it was verified that the white pigment is TiO 2 , the

  9. Using blood cytokine measures to define high inflammatory biotype of schizophrenia and schizoaffective disorder.

    Science.gov (United States)

    Boerrigter, Danny; Weickert, Thomas W; Lenroot, Rhoshel; O'Donnell, Maryanne; Galletly, Cherrie; Liu, Dennis; Burgess, Martin; Cadiz, Roxanne; Jacomb, Isabella; Catts, Vibeke S; Fillman, Stu G; Weickert, Cynthia Shannon

    2017-09-18

    Increases in pro-inflammatory cytokines are found in the brain and blood of people with schizophrenia. However, increased cytokines are not evident in all people with schizophrenia, but are found in a subset. The cytokine changes that best define this subset, termed the "elevated inflammatory biotype", are still being identified. Using quantitative RT-PCR, we measured five cytokine mRNAs (IL-1β, IL-2 IL-6, IL-8 and IL-18) from peripheral blood of healthy controls and of people with schizophrenia or schizoaffective disorder (n = 165). We used a cluster analysis of the transcript levels to define those with low and those with elevated levels of cytokine expression. From the same cohort, eight cytokine proteins (IL-1β, IL-2, IL-6, IL-8, IL-10, IL-12, IFNγ and TNFα) were measured in serum and plasma using a Luminex Magpix-based assay. We compared peripheral mRNA and protein levels across diagnostic groups and between those with low and elevated levels of cytokine expression according to our transcription-based cluster analysis. We found an overall decrease in the anti-inflammatory IL-2 mRNA (p = 0.006) and an increase in three serum cytokines, IL-6 (p = 0.010), IL-8 (p = 0.024) and TNFα (p schizophrenia compared to healthy controls. A greater percentage of people with schizophrenia (48%) were categorised into the elevated inflammatory biotype compared to healthy controls (33%). The magnitude of increase in IL-1β, IL-6, IL-8 and IL-10 mRNAs in people in the elevated inflammation biotype ranged from 100 to 220% of those in the non-elevated inflammatory biotype and was comparable between control and schizophrenia groups. Blood cytokine protein levels did not correlate with cytokine mRNA levels, and plasma levels of only two cytokines distinguished the elevated and low inflammatory biotypes, with IL-1β significantly increased in the elevated cytokine control group and IL-8 significantly increased in the elevated cytokine schizophrenia group. Our results

  10. A composite peripheral blood gene expression measure as a potential diagnostic biomarker in bipolar disorder

    DEFF Research Database (Denmark)

    Munkholm, Klaus; Peijs, L; Vinberg, M

    2015-01-01

    as a diagnostic and state biomarker in bipolar disorder. First, messenger RNA levels of 19 candidate genes were assessed in peripheral blood mononuclear cells of 37 rapid cycling bipolar disorder patients in different affective states (depression, mania and euthymia) during a 6-12-month period and in 40 age...... subjects. In patients with bipolar disorder, upregulation of NDUFV2 was observed in a depressed state compared with a euthymic state. The composite gene expression measure for discrimination between patients and healthy control subjects on the basis of 19 genes generated an area under the receiver...

  11. Measuring DSM-5 internet gaming disorder: development and validation of a short psychometric scale

    OpenAIRE

    Pontes, HM; Griffiths, MD

    2015-01-01

    Despite the large growth on gaming behaviour research, little has been done to overcome the problem stemming from the heterogeneity of gaming addiction nomenclature and the use of non-standardised measurement tools. Following the recent inclusion of Internet Gaming Disorder [IGD] as a condition worthy of future studies in the fifth edition of the Diagnostic and Statistical Manual of Mental Disorders [DSM-5], researchers have now an opportunity to reach consensus and unification in the field. ...

  12. Measurement of temperament and character in mood disorders: a model of fundamental states as personality types.

    Science.gov (United States)

    Cloninger, C R; Bayon, C; Svrakic, D M

    1998-10-01

    Personality assessment may allow reliable measurement of risk of mood disorders. A group of adults (804) representative of the general population were assessed by questionnaire. Personality types were measured by the Temperament and Character Inventory (TCI). Specific TCI configurations define personality types that can be described as hyperthymic, cyclothymic, irritable, and depressive. Each type had a unique profile of emotions, suicide attempts, and hospitalization. TCI traits are associated with mood disorders. Different ways of measuring Kraepelinean subtypes may disagree. Whether differences in personality cause psychopathology, or vice versa, remains uncertain. Personality profiles help in assessing suicidality and planning treatment.

  13. Quantitative measurements of intercellular adhesion between a macrophage and cancer cells using a cup-attached AFM chip.

    Science.gov (United States)

    Kim, Hyonchol; Yamagishi, Ayana; Imaizumi, Miku; Onomura, Yui; Nagasaki, Akira; Miyagi, Yohei; Okada, Tomoko; Nakamura, Chikashi

    2017-07-01

    Intercellular adhesion between a macrophage and cancer cells was quantitatively measured using atomic force microscopy (AFM). Cup-shaped metal hemispheres were fabricated using polystyrene particles as a template, and a cup was attached to the apex of the AFM cantilever. The cup-attached AFM chip (cup-chip) approached a murine macrophage cell (J774.2), the cell was captured on the inner concave of the cup, and picked up by withdrawing the cup-chip from the substrate. The cell-attached chip was advanced towards a murine breast cancer cell (FP10SC2), and intercellular adhesion between the two cells was quantitatively measured. To compare cell adhesion strength, the work required to separate two adhered cells (separation work) was used as a parameter. Separation work was almost 2-fold larger between a J774.2 cell and FP10SC2 cell than between J774.2 cell and three additional different cancer cells (4T1E, MAT-LyLu, and U-2OS), two FP10SC2 cells, or two J774.2 cells. FP10SC2 was established from 4T1E as a highly metastatic cell line, indicates separation work increased as the malignancy of cancer cells became higher. One possible explanation of the strong adhesion of macrophages to cancer cells observed in this study is that the measurement condition mimicked the microenvironment of tumor-associated macrophages (TAMs) in vivo, and J774.2 cells strongly expressed CD204, which is a marker of TAMs. The results of the present study, which were obtained by measuring cell adhesion strength quantitatively, indicate that the fabricated cup-chip is a useful tool for measuring intercellular adhesion easily and quantitatively. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Measuring Anxiety as a Treatment Endpoint in Youth with Autism Spectrum Disorder

    Science.gov (United States)

    Lecavalier, Luc; Wood, Jeffrey J.; Halladay, Alycia K.; Jones, Nancy E.; Aman, Michael G.; Cook, Edwin H.; Handen, Benjamin L.; King, Bryan H.; Pearson, Deborah A.; Hallett, Victoria; Sullivan, Katherine Anne; Grondhuis, Sabrina; Bishop, Somer L.; Horrigan, Joseph P.; Dawson, Geraldine; Scahill, Lawrence

    2014-01-01

    Despite the high rate of anxiety in individuals with autism spectrum disorder (ASD), measuring anxiety in ASD is fraught with uncertainty. This is due, in part, to incomplete consensus on the manifestations of anxiety in this population. Autism Speaks assembled a panel of experts to conduct a systematic review of available measures for anxiety in…

  15. Childhood Trauma Questionnaire: factor structure, measurement invariance, and validity across emotional disorders

    NARCIS (Netherlands)

    Spinhoven, P.; Penninx, B.W.; Hickendorff, M.; van Hemert, A.M.; Bernstein, D.P.; Elzinga, B.M.

    2014-01-01

    To study the psychometric properties of the Childhood Trauma Questionnaire-Short Form (CTQ-SF), we determined its dimensional structure, measurement invariance across presence of emotional disorders, the association of the CTQ-SF with an analogous interview-based measure (CTI) across presence of

  16. Outcomes Measurement in Voice Disorders: Application of an Acoustic Index of Dysphonia Severity

    Science.gov (United States)

    Awan, Shaheen N.; Roy, Nelson

    2009-01-01

    Purpose: The purpose of this experiment was to assess the ability of an acoustic model composed of both time-based and spectral-based measures to track change following voice disorder treatment and to serve as a possible treatment outcomes measure. Method: A weighted, four-factor acoustic algorithm consisting of shimmer, pitch sigma, the ratio of…

  17. Measured Gene-by-Environment Interaction in Relation to Attention-Deficit/Hyperactivity Disorder

    Science.gov (United States)

    Nigg, Joel; Nikolas, Molly; Burt, S. Alexandra

    2010-01-01

    Objective: To summarize and evaluate the state of knowledge regarding the role of measured gene-by-environment interactions in relation to attention-deficit/hyperactivity disorder. Method: A selective review of methodologic issues was followed by a systematic search for relevant articles on measured gene-by-environment interactions; the search…

  18. Quantitative and subjective behavioural aspects in the assessment of attention-deficit hyperactivity disorder (ADHD) in adults.

    Science.gov (United States)

    Söderström, Staffan; Pettersson, Richard; Nilsson, Kent W

    2014-01-01

    Self-rating scales and cognitive tests are instruments used in the assessment of attention-deficit hyperactivity disorder (ADHD). However, few studies have examined the differential validity of these kinds of instruments in psychiatric samples. To examine the discriminative validity of two self-report scales (ADHD Self-Report Scale [ASRS v.1.1], Current Symptom Scale [CSS]) and a continuous performance test with measures of motor activity (QBTest Plus). The interrelation between the instruments, and their abilities to differentiate between patients with an ADHD diagnosis and non-ADHD patients referred for psychiatric assessment were examined in a naturalistic sample of 61 adult patients. The area under the receiver operating characteristic curve (AUC) for the dichotomized versions of the test variables in all tests ranged from 0.61 to 0.71. The ASRS and CSS exhibited sensitivity of 90.2% and 85.4%, and specificity of 35.0% and 40.0%, respectively. Variables from the QBTest Plus showed the opposite result for the variables QBImpulsivity and QBInattention, with sensitivity of 58.5% and 36.3% and specificity of 80.0% and 100.0%. Sensitivity and specificity of QBActivity were 68.3% and 65.0%, respectively. A stepwise discriminant function analysis showed that two variables from the QBTest Plus--QBInattention and QBActivity--accounted for 22.8% of the between-group variability, with the strongest predictor being QBInattention. The function yielded an overall correct classification of 72.1%. The classification correctly identified 87.8% of patients diagnosed with ADHD and 40.0% of non-ADHD patients. The discriminant validity of self-rating scales and the more objective measure of ADHD symptoms are poor and should be integrated generally with other sources of data.

  19. Quantitatively assessed CT imaging measures of pulmonary interstitial pneumonia: Effects of reconstruction algorithms on histogram parameters

    International Nuclear Information System (INIS)

    Koyama, Hisanobu; Ohno, Yoshiharu; Yamazaki, Youichi; Nogami, Munenobu; Kusaka, Akiko; Murase, Kenya; Sugimura, Kazuro

    2010-01-01

    This study aimed the influences of reconstruction algorithm for quantitative assessments in interstitial pneumonia patients. A total of 25 collagen vascular disease patients (nine male patients and 16 female patients; mean age, 57.2 years; age range 32-77 years) underwent thin-section MDCT examinations, and MDCT data were reconstructed with three kinds of reconstruction algorithm (two high-frequencies [A and B] and one standard [C]). In reconstruction algorithm B, the effect of low- and middle-frequency space was suppressed compared with reconstruction algorithm A. As quantitative CT parameters, kurtosis, skewness, and mean lung density (MLD) were acquired from a frequency histogram of the whole lung parenchyma in each reconstruction algorithm. To determine the difference of quantitative CT parameters affected by reconstruction algorithms, these parameters were compared statistically. To determine the relationships with the disease severity, these parameters were correlated with PFTs. In the results, all the histogram parameters values had significant differences each other (p < 0.0001) and those of reconstruction algorithm C were the highest. All MLDs had fair or moderate correlation with all parameters of PFT (-0.64 < r < -0.45, p < 0.05). Though kurtosis and skewness in high-frequency reconstruction algorithm A had significant correlations with all parameters of PFT (-0.61 < r < -0.45, p < 0.05), there were significant correlations only with diffusing capacity of carbon monoxide (DLco) and total lung capacity (TLC) in reconstruction algorithm C and with forced expiratory volume in 1 s (FEV1), DLco and TLC in reconstruction algorithm B. In conclusion, reconstruction algorithm has influence to quantitative assessments on chest thin-section MDCT examination in interstitial pneumonia patients.

  20. Measurement parameter selection for quantitative isotope dilution gas chromatography/mass spectrometry

    International Nuclear Information System (INIS)

    Colby, B.N.; Rosecrance, A.E.; Colby, M.E.

    1981-01-01

    By use of the two-isotope model of isotope dilution, selection criteria were developed for identifying optimum m/z's for quantitation of compounds by gas chromatography/mass spectrometry. In addition, it was possible to predict the optimum ratio of naturally abundant to labeled compound and to identify appropriate data reduction methods. The validity of these predictions was confirmed by using experimental GC/MS data for several organic compounds

  1. Quantitatively assessed CT imaging measures of pulmonary interstitial pneumonia: Effects of reconstruction algorithms on histogram parameters

    Energy Technology Data Exchange (ETDEWEB)

    Koyama, Hisanobu [Department of Radiology, Hyogo Kaibara Hospital, 5208-1 Kaibara, Kaibara-cho, Tanba 669-3395 (Japan)], E-mail: hisanobu19760104@yahoo.co.jp; Ohno, Yoshiharu [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan)], E-mail: yosirad@kobe-u.ac.jp; Yamazaki, Youichi [Department of Medical Physics and Engineering, Faculty of Health Sciences, Graduate School of Medicine, Osaka University, 1-7 Yamadaoka, Suita 565-0871 (Japan)], E-mail: y.yamazk@sahs.med.osaka-u.ac.jp; Nogami, Munenobu [Division of PET, Institute of Biomedical Research and Innovation, 2-2 MInamimachi, Minatojima, Chu0-ku, Kobe 650-0047 (Japan)], E-mail: aznogami@fbri.org; Kusaka, Akiko [Division of Radiology, Kobe University Hospital, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan)], E-mail: a.kusaka@hosp.kobe-u.ac.jp; Murase, Kenya [Department of Medical Physics and Engineering, Faculty of Health Sciences, Graduate School of Medicine, Osaka University, 1-7 Yamadaoka, Suita 565-0871 (Japan)], E-mail: murase@sahs.med.osaka-u.ac.jp; Sugimura, Kazuro [Department of Radiology, Kobe University Graduate School of Medicine, 7-5-2 Kusunoki-cho, Chuo-ku, Kobe 650-0017 (Japan)], E-mail: sugimura@med.kobe-u.ac.jp

    2010-04-15

    This study aimed the influences of reconstruction algorithm for quantitative assessments in interstitial pneumonia patients. A total of 25 collagen vascular disease patients (nine male patients and 16 female patients; mean age, 57.2 years; age range 32-77 years) underwent thin-section MDCT examinations, and MDCT data were reconstructed with three kinds of reconstruction algorithm (two high-frequencies [A and B] and one standard [C]). In reconstruction algorithm B, the effect of low- and middle-frequency space was suppressed compared with reconstruction algorithm A. As quantitative CT parameters, kurtosis, skewness, and mean lung density (MLD) were acquired from a frequency histogram of the whole lung parenchyma in each reconstruction algorithm. To determine the difference of quantitative CT parameters affected by reconstruction algorithms, these parameters were compared statistically. To determine the relationships with the disease severity, these parameters were correlated with PFTs. In the results, all the histogram parameters values had significant differences each other (p < 0.0001) and those of reconstruction algorithm C were the highest. All MLDs had fair or moderate correlation with all parameters of PFT (-0.64 < r < -0.45, p < 0.05). Though kurtosis and skewness in high-frequency reconstruction algorithm A had significant correlations with all parameters of PFT (-0.61 < r < -0.45, p < 0.05), there were significant correlations only with diffusing capacity of carbon monoxide (DLco) and total lung capacity (TLC) in reconstruction algorithm C and with forced expiratory volume in 1 s (FEV1), DLco and TLC in reconstruction algorithm B. In conclusion, reconstruction algorithm has influence to quantitative assessments on chest thin-section MDCT examination in interstitial pneumonia patients.

  2. What Do Patients Think about the Cause of Their Mental Disorder? A Qualitative and Quantitative Analysis of Causal Beliefs of Mental Disorder in Inpatients in Psychosomatic Rehabilitation.

    Science.gov (United States)

    Magaard, Julia Luise; Schulz, Holger; Brütt, Anna Levke

    2017-01-01

    Patients' causal beliefs about their mental disorders are important for treatment because they affect illness-related behaviours. However, there are few studies exploring patients' causal beliefs about their mental disorder. (a) To qualitatively explore patients' causal beliefs of their mental disorder, (b) to explore frequencies of patients stating causal beliefs, and (c) to investigate differences of causal beliefs according to patients' primary diagnoses. Inpatients in psychosomatic rehabilitation were asked an open-ended question about their three most important causal beliefs about their mental illness. Answers were obtained from 678 patients, with primary diagnoses of depression (N = 341), adjustment disorder (N = 75), reaction to severe stress (N = 57) and anxiety disorders (N = 40). Two researchers developed a category system inductively and categorised the reported causal beliefs. Qualitative analysis has been supplemented by logistic regression analyses. The causal beliefs were organized into twelve content-related categories. Causal beliefs referring to "problems at work" (47%) and "problems in social environment" (46%) were most frequently mentioned by patients with mental disorders. 35% of patients indicate causal beliefs related to "self/internal states". Patients with depression and patients with anxiety disorders stated similar causal beliefs, whereas patients with reactions to severe stress and adjustment disorders stated different causal beliefs in comparison to patients with depression. There was no opportunity for further exploration, because we analysed written documents. These results add a detailed insight to mentally ill patients' causal beliefs to illness perception literature. Additionally, evidence about differences in frequencies of causal beliefs between different illness groups complement previous findings. For future research it is important to clarify the relation between patients' causal beliefs and the chosen treatment.

  3. What Do Patients Think about the Cause of Their Mental Disorder? A Qualitative and Quantitative Analysis of Causal Beliefs of Mental Disorder in Inpatients in Psychosomatic Rehabilitation.

    Directory of Open Access Journals (Sweden)

    Julia Luise Magaard

    Full Text Available Patients' causal beliefs about their mental disorders are important for treatment because they affect illness-related behaviours. However, there are few studies exploring patients' causal beliefs about their mental disorder.(a To qualitatively explore patients' causal beliefs of their mental disorder, (b to explore frequencies of patients stating causal beliefs, and (c to investigate differences of causal beliefs according to patients' primary diagnoses.Inpatients in psychosomatic rehabilitation were asked an open-ended question about their three most important causal beliefs about their mental illness. Answers were obtained from 678 patients, with primary diagnoses of depression (N = 341, adjustment disorder (N = 75, reaction to severe stress (N = 57 and anxiety disorders (N = 40. Two researchers developed a category system inductively and categorised the reported causal beliefs. Qualitative analysis has been supplemented by logistic regression analyses.The causal beliefs were organized into twelve content-related categories. Causal beliefs referring to "problems at work" (47% and "problems in social environment" (46% were most frequently mentioned by patients with mental disorders. 35% of patients indicate causal beliefs related to "self/internal states". Patients with depression and patients with anxiety disorders stated similar causal beliefs, whereas patients with reactions to severe stress and adjustment disorders stated different causal beliefs in comparison to patients with depression.There was no opportunity for further exploration, because we analysed written documents.These results add a detailed insight to mentally ill patients' causal beliefs to illness perception literature. Additionally, evidence about differences in frequencies of causal beliefs between different illness groups complement previous findings. For future research it is important to clarify the relation between patients' causal beliefs and the chosen treatment.

  4. Proficiency testing as a basis for estimating uncertainty of measurement: application to forensic alcohol and toxicology quantitations.

    Science.gov (United States)

    Wallace, Jack

    2010-05-01

    While forensic laboratories will soon be required to estimate uncertainties of measurement for those quantitations reported to the end users of the information, the procedures for estimating this have been little discussed in the forensic literature. This article illustrates how proficiency test results provide the basis for estimating uncertainties in three instances: (i) For breath alcohol analyzers the interlaboratory precision is taken as a direct measure of uncertainty. This approach applies when the number of proficiency tests is small. (ii) For blood alcohol, the uncertainty is calculated from the differences between the laboratory's proficiency testing results and the mean quantitations determined by the participants; this approach applies when the laboratory has participated in a large number of tests. (iii) For toxicology, either of these approaches is useful for estimating comparability between laboratories, but not for estimating absolute accuracy. It is seen that data from proficiency tests enable estimates of uncertainty that are empirical, simple, thorough, and applicable to a wide range of concentrations.

  5. Quantitative computed tomography measurements to evaluate airway disease in chronic obstructive pulmonary disease: Relationship to physiological measurements, clinical index and visual assessment of airway disease

    International Nuclear Information System (INIS)

    Nambu, Atsushi; Zach, Jordan; Schroeder, Joyce; Jin, Gongyoung; Kim, Song Soo; Kim, Yu-IL; Schnell, Christina; Bowler, Russell; Lynch, David A.

    2016-01-01

    Purpose: To correlate currently available quantitative CT measurements for airway disease with physiological indices and the body-mass index, airflow obstruction, dyspnea, and exercise capacity (BODE) index in patients with chronic obstructive pulmonary disease (COPD). Materials and methods: This study was approved by our institutional review board (IRB number 2778). Written informed consent was obtained from all subjects. The subjects included 188 current and former cigarette smokers from the COPDGene cohort who underwent inspiratory and expiratory CT and also had physiological measurements for the evaluation of airflow limitation, including FEF25-75%, airway resistance (Raw), and specific airway conductance (sGaw). The BODE index was used as the index of clinical symptoms. Quantitative CT measures included % low attenuation areas [% voxels ≤ 950 Hounsfield unit (HU) on inspiratory CT, %LAA −950ins ], percent gas trapping (% voxels ≤ −856 HU on expiratory CT, %LAA −856exp ), relative inspiratory to expiratory volume change of voxels with attenuation values from −856 to −950 HU [Relative Volume Change (RVC) −856 to −950 ], expiratory to inspiratory ratio of mean lung density (E/I-ratio MLD ), Pi10, and airway wall thickness (WT), luminal diameter (LD) and airway wall area percent (WA%) in the segmental, subsegmental and subsubsegmental bronchi on inspiratory CT. Correlation coefficients were calculated between the QCT measurements and physiological measurements in all subjects and in the subjects with mild emphysema (%LAA −950ins <10%). Univariate and multiple variable analysis for the BODE index were also performed. Adjustments were made for age, gender, smoking pack years, FEF25-75%, Raw, and sGaw. Results: Quantitative CT measurements had significant correlations with physiological indices. Among them, E/I-ratio MLD had the strongest correlations with FEF25-75% (r = −0.648, <0.001) and sGaw (r = −0.624, <0.001) while in the subjects with

  6. Porous Silicon Antibody Microarrays for Quantitative Analysis: Measurement of Free and Total PSA in Clinical Plasma Samples

    Science.gov (United States)

    Tojo, Axel; Malm, Johan; Marko-Varga, György; Lilja, Hans; Laurell, Thomas

    2014-01-01

    The antibody microarrays have become widespread, but their use for quantitative analyses in clinical samples has not yet been established. We investigated an immunoassay based on nanoporous silicon antibody microarrays for quantification of total prostate-specific-antigen (PSA) in 80 clinical plasma samples, and provide quantitative data from a duplex microarray assay that simultaneously quantifies free and total PSA in plasma. To further develop the assay the porous silicon chips was placed into a standard 96-well microtiter plate for higher throughput analysis. The samples analyzed by this quantitative microarray were 80 plasma samples obtained from men undergoing clinical PSA testing (dynamic range: 0.14-44ng/ml, LOD: 0.14ng/ml). The second dataset, measuring free PSA (dynamic range: 0.40-74.9ng/ml, LOD: 0.47ng/ml) and total PSA (dynamic range: 0.87-295ng/ml, LOD: 0.76ng/ml), was also obtained from the clinical routine. The reference for the quantification was a commercially available assay, the ProStatus PSA Free/Total DELFIA. In an analysis of 80 plasma samples the microarray platform performs well across the range of total PSA levels. This assay might have the potential to substitute for the large-scale microtiter plate format in diagnostic applications. The duplex assay paves the way for a future quantitative multiplex assay, which analyses several prostate cancer biomarkers simultaneously. PMID:22921878

  7. Stable xenon CT CBF measurements in prevalent cerebrovascular disorders (stroke)

    International Nuclear Information System (INIS)

    Meyer, J.S.; Okayasu, H.; Tachibana, H.; Okabe, T.

    1984-01-01

    Local cerebral blood flow (LCBF) and local tissue: blood partition coefficient (L lambda) values were measured for small volumes of gray or white matter by CT CBF. Single compartment analysis was used but fitted to infinity in normal volunteers aged between 20 to 100 years (N . 20). Hemispheric LCBF and L lambda values were compared to those of 61 age matched patients with transient ischemic attacks (TIAs, N . 10), reversible ischemic neurologic deficits (RINDS, N . 10), acute and chronic cerebral infarctions associated with emboli from atherosclerotic plaques or complete occlusion of internal carotid or middle cerebral arteries (n . 9) or of cardiac origin (N . 3), cerebral hemorrhage (N . 1), multi-infarct dementia (MID) (N . 11) and arteriovenous malformations (AVM) (N . 17). In normal aging, L lambda s were normal, but LCBF showed diffuse age-related declines. Symptomatic cerebrovascular disease was characterized by accentuation of age-related LCBF declines. TIAs with unilateral ICA occlusion showed bilateral reductions of LCBF more evident in ischemic hemispheres. TIAs due to fibrino-platelet emboli from ulcerated, non-occlusive ICA plaques were characterized by transient unilateral, localized LCBF reductions. All TIAs showed normal L lambda values. RINDS showed both LCBF and L lambda reductions. Larger embolic infarctions of ICA origin, whether acute or chronic, showed zones of zero flow with surrounding reductions of LCBF and L lambda values. Recent cerebral embolism of cardiac origin likewise exhibited zones of zero flow surrounded by reduced LCBF and L lambda values; but in chronic stages LCBF and L lambda values adjacent to zero flow zones were normal. MID was characterized by patchy reductions of LCBF and L lambda values throughout both hemispheres. Brain tissues surrounding AVM showed normal L lambda values but LCBF values were reduced due to steal

  8. Sleep/Wake Physiology and Quantitative Electroencephalogram Analysis of the Neuroligin-3 Knockout Rat Model of Autism Spectrum Disorder.

    Science.gov (United States)

    Thomas, Alexia M; Schwartz, Michael D; Saxe, Michael D; Kilduff, Thomas S

    2017-10-01

    Neuroligin-3 (NLGN3) is one of the many genes associated with autism spectrum disorder (ASD). Sleep dysfunction is highly prevalent in ASD, but has not been rigorously examined in ASD models. Here, we evaluated sleep/wake physiology and behavioral phenotypes of rats with genetic ablation of Nlgn3. Male Nlgn3 knockout (KO) and wild-type (WT) rats were assessed using a test battery for ASD-related behaviors and also implanted with telemeters to record the electroencephalogram (EEG), electromyogram, body temperature, and locomotor activity. 24-h EEG recordings were analyzed for sleep/wake states and spectral composition. Nlgn3 KO rats were hyperactive, exhibited excessive chewing behavior, and had impaired prepulse inhibition to an auditory startle stimulus. KO rats also spent less time in non-rapid eye movement (NREM) sleep, more time in rapid eye movement (REM) sleep, exhibited elevated theta power (4-9 Hz) during wakefulness and REM, and elevated delta power (0.5-4 Hz) during NREM. Beta (12-30 Hz) power and gamma (30-50 Hz) power were suppressed across all vigilance states. The sleep disruptions in Nlgn3 KO rats are consistent with observations of sleep disturbances in ASD patients. The EEG provides objective measures of brain function to complement rodent behavioral analyses and therefore may be a useful tool to study ASD. © Sleep Research Society 2017. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  9. Quantitative assay for the measurement of immune responses directed against the human placenta

    Energy Technology Data Exchange (ETDEWEB)

    Davies, M; Sutcliffe, R G [Glasgow Univ. (UK)

    1982-02-12

    A quantitative in vitro immune assay based on the classical chromium release assay has been developed to detect immune responses directed against alien antigens expressed by the developing foetus and present on the maternal-facing surface of the human placenta. A plasma membrane fraction from the surface of the placenta was prepared and the vesicles thus formed were radiolabelled with /sup 51/Cr. The /sup 51/Cr-labelled vesicles, by various criteria, were found to be suitable for use as targets in a release assay. Further, by means of experimentally immunised animals, the target membranes were shown to be capable of detecting both cellular and humoral anti-placental activity.

  10. Quantitative assessment of isolated rapid eye movement (REM) sleep without atonia without clinical REM sleep behavior disorder: clinical and research implications.

    Science.gov (United States)

    Sasai-Sakuma, Taeko; Frauscher, Birgit; Mitterling, Thomas; Ehrmann, Laura; Gabelia, David; Brandauer, Elisabeth; Inoue, Yuichi; Poewe, Werner; Högl, Birgit

    2014-09-01

    Rapid eye movement (REM) sleep without atonia (RWA) is observed in some patients without a clinical history of REM sleep behavior disorder (RBD). It remains unknown whether these patients meet the refined quantitative electromyographic (EMG) criteria supporting a clinical RBD diagnosis. We quantitatively evaluated EMG activity and investigated its overnight distribution in patients with isolated qualitative RWA. Fifty participants with an incidental polysomnographic finding of RWA (isolated qualitative RWA) were included. Tonic, phasic, and 'any' EMG activity during REM sleep on PSG were quantified retrospectively. Referring to the quantitative cut-off values for a polysomnographic diagnosis of RBD, 7/50 (14%) and 6/50 (12%) of the patients showed phasic and 'any' EMG activity in the mentalis muscle above the respective cut-off values. No patient was above the cut-off value for tonic EMG activity or phasic EMG activity in the anterior tibialis muscles. Patients with RWA above the cut-off value showed higher amounts of RWA during later REM sleep periods. This is the first study showing that some subjects with incidental RWA meet the refined quantitative EMG criteria for a diagnosis of RBD. Future longitudinal studies must investigate whether this subgroup with isolated qualitative RWA is at an increased risk of developing fully expressed RBD and/or neurodegenerative disease. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Disorder in YBa2Cu3O7 by entropy measurements and by rf dissipation

    International Nuclear Information System (INIS)

    Acrivos, J.V.; Inthnin, R.; Bustillo, C.; Lei, M.C.; Hellmoldt, D.

    1989-01-01

    Experiments, that characterize the disorder present in Type II superconducting ceramics, are reported Electrochemical measurements at 298>T>150 K>T c ∼ 92 K, in the cell: Cu|CuBr 2 .05 M in CH 3 OH|1:2:3|Pt and/orCu, obtain important thermochemical information, ΔH cell = 30 kJ/mole e - and ΔS cell = 212 J/K/mole e - ± 15%. This suggests that the 1:2:3 phase is disordered. The rf dissipation measurements of superconducting lamellae dispersed in a matrix give information on the effects of the static and rf fields on the mixed state

  12. Theoretical approach on microscopic bases of stochastic functional self-organization: quantitative measures of the organizational degree of the environment

    Energy Technology Data Exchange (ETDEWEB)

    Oprisan, Sorinel Adrian [Department of Psychology, University of New Orleans, New Orleans, LA (United States)]. E-mail: soprisan@uno.edu

    2001-11-30

    There has been increased theoretical and experimental research interest in autonomous mobile robots exhibiting cooperative behaviour. This paper provides consistent quantitative measures of organizational degree of a two-dimensional environment. We proved, by the way of numerical simulations, that the theoretically derived values of the feature are reliable measures of aggregation degree. The slope of the feature's dependence on memory radius leads to an optimization criterion for stochastic functional self-organization. We also described the intellectual heritages that have guided our research, as well as possible future developments. (author)

  13. A quantitative assay measuring the function of lipase maturation factor 1

    Science.gov (United States)

    Yin, Fen; Doolittle, Mark H.; Péterfy, Miklós

    2009-01-01

    Newly synthesized lipoprotein lipase (LPL) and related members of the lipase gene family require an endoplasmic reticulum maturation factor for attainment of enzyme activity. This factor has been identified as lipase maturation factor 1 (Lmf1), and mutations affecting its function and/or expression result in combined lipase deficiency (cld) and hypertriglyceridemia. To assess the functional impact of Lmf1 sequence variations, both naturally occurring and induced, we report the development of a cell-based assay using LPL activity as a quantitative reporter of Lmf1 function. The assay uses a cell line homozygous for the cld mutation, which renders endogenous Lmf1 nonfunctional. LPL transfected into the mutant cld cell line fails to attain activity; however, cotransfection of LPL with wild-type Lmf1 restores its ability to support normal lipase maturation. In this report, we describe optimized conditions that ensure the detection of a complete range of Lmf1 function (full, partial, or complete loss of function) using LPL activity as the quantitative reporter. To illustrate the dynamic range of the assay, we tested several novel mutations in mouse Lmf1. Our results demonstrate the ability of the assay to detect and analyze Lmf1 mutations having a wide range of effects on Lmf1 function and protein expression. PMID:19471043

  14. Recovery from eating disorders: psychometric properties of a patient-related measure

    Directory of Open Access Journals (Sweden)

    Rosenvinge JH

    2012-11-01

    Full Text Available Gunn Pettersen,1 Kari-Brith Thune-Larsen,2 Jan H Rosenvinge31Department of Health and Care Sciences, Faculty of Health Sciences, University of Tromsø, Tromsø, Norway; 2Oslo University Hospital, Oslo, Norway; 3Department of Psychology, Faculty of Health Sciences, University of Tromsø, Tromsø, NorwayAbstract: Although there are numerous lists of items covering clinically valid aspects of recovery from eating disorders, these lists are on the nominal level: the potential for multidimensional development has not been explored. Such exploration is the purpose of the present study. The subjects included in the study were 152 female clinicians, 1052 females randomly selected from the general population, and 184 eating-disorder patients. All subjects rated 17 recovery items on a 10-point scale in terms of their relevance and importance. They also completed measures of knowledge about eating disorders and their own eating problems, in addition to providing information about their age and personal acquaintance with eating disorders. Fourteen recovery-item scores were sample unspecific, and hence all samples tended to judge the majority of items in a similar manner. The 17 items successfully formed three separate factors covering specific eating-disorder symptoms, as well as social and psychological issues. The clinician and general population sample analyzed together provided a more condensed scale comprising two factors (specific eating-disorder symptoms and psychosocial factors, with each factor having three items. This factor structure was successfully replicated using the patient-validation sample. The findings indicate an empirical basis for a valid recovery measure that may be suitable in future outcome research.Keywords: eating disorders, recovery, outcome, outcome measures

  15. Quantitative MR imaging of intra-orbital structures: Tissue-specific measurements and age dependency compared to extra-orbital structures using multispectral quantitative MR imaging.

    Science.gov (United States)

    Watanabe, Memi; Buch, Karen; Fujita, Akifumi; Jara, Hernán; Qureshi, Muhammad Mustafa; Sakai, Osamu

    2017-08-01

    The orbit can be affected by unique pathologic conditions and often requires MRI evaluation. The purpose of this study was to investigate the age-related changes in multiple intra-orbital structures using quantitative MRI (qMRI). Thirty-eight subjects (20 males, 18 females; ages 0.5-87 years) underwent MRI with a mixed turbo spin echo sequence. T1 and T2 measurements were obtained within ROI in 6 intra-orbital structures (medial and lateral rectus muscles, medial and lateral retrobulbar fat, lacrimal gland, and optic nerve), and compared with those of corresponding extra-orbital structures (masseter muscle, subcutaneous cheek fat, buccal fat, parotid gland, and frontal white matter). Statistical analyses were performed using Pearson's correlation coefficients. T1 and T2 values of the extra-ocular muscles increased with age, with higher T1 and T2 values compared to the masseter muscles. Retrobulbar fat showed significant age-associated increases in T1 values in the lateral side and in T2 values in both sides. T1 and T2 values in the lacrimal gland increased with age, while the parotid gland showed an age-associated increase in T2 values and decrease in T1 values. Optic nerves demonstrated age-related changes, similar to that of frontal white matter; rapid decreases with age in T1 and T2 times in early stages of life, and slight increases in T1 and T2 times later in life. Intra-orbital structures demonstrated specific qMRI measurements and aging patterns, which were different from extra-orbital structures. Location-specific age-related changes of intra-orbital structures should be considered in the qMRI assessment of the orbital pathology.

  16. Comparison of Quantitative Cartilage T2 Measurements and Qualitative MR Imaging between Professional Ballet Dancers and Healthy Volunteers.

    Science.gov (United States)

    Cha, Jang Gyu; Yi, Ji Sook; Han, Jong Kyu; Lee, Young Koo

    2015-07-01

    To compare qualitative magnetic resonance (MR) images and quantitative T2 measurements of the tibiotalar cartilage between ballerinas and healthy volunteers. Institutional review board approval for this study and informed consent (from all participants) were obtained. MR examinations were performed by using a 3-T MR imaging system with 21 professional female ballet dancers and 20 healthy female volunteers. Two musculoskeletal radiologists qualitatively measured tibiotalar cartilage T2 values in the anterior zones, middle zones, and posterior zones of cartilage. MR findings were also qualitatively analyzed in both groups. The tibial cartilage T2 values measured in the anterior and posterior zones and the talar cartilage T2 values measured in all three zones were significantly higher in the ballerina group than in the control group (P The posterior zones exhibited the highest T2 values among the three tibiotalar cartilage zones in both groups (P the presence of posterior soft-tissue edema (P = .001) and flexor hallucis longus tenosynovitis (P The findings showed a trend toward increasing cartilage T2 values in ballerinas when compared with control subjects, indicating that quantitative T2 measurement may potentially be used as a noninvasive imaging tool for early detection of cartilage lesions in the tibiotalar joint.

  17. Quantitative photoacoustic integrating sphere (QPAIS platform for absorption coefficient and Grüneisen parameter measurements: Demonstration with human blood

    Directory of Open Access Journals (Sweden)

    Yolanda Villanueva-Palero

    2017-06-01

    Full Text Available Quantitative photoacoustic imaging in biomedicine relies on accurate measurements of relevant material properties of target absorbers. Here, we present a method for simultaneous measurements of the absorption coefficient and Grüneisen parameter of small volume of liquid scattering and absorbing media using a coupled-integrating sphere system which we refer to as quantitative photoacoustic integrating sphere (QPAIS platform. The derived equations do not require absolute magnitudes of optical energy and pressure values, only calibration of the setup using aqueous ink dilutions is necessary. As a demonstration, measurements with blood samples from various human donors are done at room and body temperatures using an incubator. Measured absorption coefficient values are consistent with known oxygen saturation dependence of blood absorption at 750 nm, whereas measured Grüneisen parameter values indicate variability among five different donors. An increasing Grüneisen parameter value with both hematocrit and temperature is observed. These observations are consistent with those reported in literature.

  18. A quantitative ELISA procedure for the measurement of membrane-bound platelet-associated IgG (PAIgG).

    Science.gov (United States)

    Lynch, D M; Lynch, J M; Howe, S E

    1985-03-01

    A quantitative ELISA assay for the measurement of in vivo bound platelet-associated IgG (PAIgG) using intact patient platelets is presented. The assay requires quantitation and standardization of the number of platelets bound to microtiter plate wells and an absorbance curve using quantitated IgG standards. Platelet-bound IgG was measured using an F(ab')2 peroxidase labeled anti-human IgG and o-phenylenediamine dihydrochloride (OPD) as the substrate. Using this assay, PAIgG for normal individuals was 2.8 +/- 1.6 fg/platelet (mean +/- 1 SD; n = 30). Increased levels were found in 28 of 30 patients with clinical autoimmune thrombocytopenia (ATP) with a range of 7.0-80 fg/platelet. Normal PAIgG levels were found in 26 of 30 patients with nonimmune thrombocytopenia. In the sample population studied, the PAIgG assay showed a sensitivity of 93%, specificity of 90%, a positive predictive value of 0.90, and a negative predictive value of 0.93. The procedure is highly reproducible (CV = 6.8%) and useful in evaluating patients with suspected immune mediated thrombocytopenia.

  19. A novel method for morphological pleomorphism and heterogeneity quantitative measurement: Named cell feature level co-occurrence matrix.

    Science.gov (United States)

    Saito, Akira; Numata, Yasushi; Hamada, Takuya; Horisawa, Tomoyoshi; Cosatto, Eric; Graf, Hans-Peter; Kuroda, Masahiko; Yamamoto, Yoichiro

    2016-01-01

    Recent developments in molecular pathology and genetic/epigenetic analysis of cancer tissue have resulted in a marked increase in objective and measurable data. In comparison, the traditional morphological analysis approach to pathology diagnosis, which can connect these molecular data and clinical diagnosis, is still mostly subjective. Even though the advent and popularization of digital pathology has provided a boost to computer-aided diagnosis, some important pathological concepts still remain largely non-quantitative and their associated data measurements depend on the pathologist's sense and experience. Such features include pleomorphism and heterogeneity. In this paper, we propose a method for the objective measurement of pleomorphism and heterogeneity, using the cell-level co-occurrence matrix. Our method is based on the widely used Gray-level co-occurrence matrix (GLCM), where relations between neighboring pixel intensity levels are captured into a co-occurrence matrix, followed by the application of analysis functions such as Haralick features. In the pathological tissue image, through image processing techniques, each nucleus can be measured and each nucleus has its own measureable features like nucleus size, roundness, contour length, intra-nucleus texture data (GLCM is one of the methods). In GLCM each nucleus in the tissue image corresponds to one pixel. In this approach the most important point is how to define the neighborhood of each nucleus. We define three types of neighborhoods of a nucleus, then create the co-occurrence matrix and apply Haralick feature functions. In each image pleomorphism and heterogeneity are then determined quantitatively. For our method, one pixel corresponds to one nucleus feature, and we therefore named our method Cell Feature Level Co-occurrence Matrix (CFLCM). We tested this method for several nucleus features. CFLCM is showed as a useful quantitative method for pleomorphism and heterogeneity on histopathological image

  20. Association between quantitative measures obtained using fluorescence-based methods and activity status of occlusal caries lesions in primary molars.

    Science.gov (United States)

    Novaes, Tatiane Fernandes; Reyes, Alessandra; Matos, Ronilza; Antunes-Pontes, Laura Regina; Marques, Renata Pereira de Samuel; Braga, Mariana Minatel; Diniz, Michele Baffi; Mendes, Fausto Medeiros

    2017-05-01

    Fluorescence-based methods (FBM) can add objectiveness to diagnosis strategy for caries. Few studies, however, have focused on the evaluation of caries activity. To evaluate the association between quantitative measures obtained with FBM, clinical parameters acquired from the patients, caries detection, and assessment of activity status in occlusal surfaces of primary molars. Six hundred and six teeth from 113 children (4-14 years) were evaluated. The presence of a biofilm, caries experience, and the number of active lesions were recorded. The teeth were assessed using FBM: DIAGNOdent pen (Lfpen) and Quantitative light-induced fluorescence (QLF). As reference standard, all teeth were evaluated using the ICDAS (International Caries Detection and Assessment System) associated with clinical activity assessments. Multilevel regressions compared the FBM values and evaluated the association between the FBM measures and clinical variables related to the caries activity. The measures from the FBM were higher in cavitated lesions. Only, ∆F values distinguished active and inactive lesions. The LFpen measures were higher in active lesions, at the cavitated threshold (56.95 ± 29.60). Following regression analyses, only the presence of visible biofilm on occlusal surfaces (adjusted prevalence ratio = 1.43) and ∆R values of the teeth (adjusted prevalence ratio = 1.02) were associated with caries activity. Some quantitative measures from FBM parameters are associated with caries activity evaluation, which is similar to the clinical evaluation of the presence of visible biofilm. © 2016 BSPD, IAPD and John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Feasibility of quantitative performance measures for evaluating nuclear power plant operators

    International Nuclear Information System (INIS)

    Carter, R.J.; Connelly, E.M.; Krois, P.A.

    1989-01-01

    A more valid measure of team performance in nuclear power plants is needed. A study is described which was oriented towards evaluating the feasibility of synthesizing performance measures by deriving measures for crews responding to an off-normal event in a full-scope simulator. The thesis was that performance assessment is based on the subjective judgment of training instructors. The procedure used to synthesize the performance measure consisted of: identification of the factors believed to be important to performance assessment, development of example crew performances and ratings on each by instructors, and derivation of the measure by capturing the instructors' assessment rules. A performance measure was derived which explains nearly all of the variance of the instructors' team performance assessments. There is reason to believe that this method of synthesizing measures can be applied to other events. 7 tabs

  2. Observation of structural universality in disordered systems using bulk diffusion measurement

    Science.gov (United States)

    Papaioannou, Antonios; Novikov, Dmitry S.; Fieremans, Els; Boutis, Gregory S.

    2017-12-01

    We report on an experimental observation of classical diffusion distinguishing between structural universality classes of disordered systems in one dimension. Samples of hyperuniform and short-range disorder were designed, characterized by the statistics of the placement of micrometer-thin parallel permeable barriers, and the time-dependent diffusion coefficient was measured by NMR methods over three orders of magnitude in time. The relation between the structural exponent, characterizing disorder universality class, and the dynamical exponent of the diffusion coefficient is experimentally verified. The experimentally established relation between structure and transport exemplifies the hierarchical nature of structural complexity—dynamics are mainly determined by the universality class, whereas microscopic parameters affect the nonuniversal coefficients. These results open the way for noninvasive characterization of structural correlations in porous media, complex materials, and biological tissues via a bulk diffusion measurement.

  3. A Quantitative Measure of Handgrip Myotonia in Non-dystrophic Myotonia

    Science.gov (United States)

    Statland, Jeffrey M; Bundy, Brian N; Wang, Yunxia; Trivedi, Jaya R; Rayan, Dipa Raja; Herbelin, Laura; Donlan, Merideth; McLin, Rhonda; Eichinger, Katy J; Findlater, Karen; Dewar, Liz; Pandya, Shree; Martens, William B; Venance, Shannon L; Matthews, Emma; Amato, Anthony A; Hanna, Michael G; Griggs, Robert C; Barohn, Richard J

    2012-01-01

    Introduction Non-dystrophic Myotonia (NDM) is characterized by myotonia without muscle wasting. A standardized quantitative myotonia assessment (QMA) is important for clinical trials. Methods Myotonia was assessed in 91 individuals enrolled in a natural history study using a commercially available computerized handgrip myometer and automated software. Average peak force and 90% to 5% relaxation times were compared to historical normal controls studied with identical methods. Results 30 subjects had chloride channel mutations, 31 sodium channel mutations, 6 DM2, and 24 no identified mutation. Chloride channel mutations were associated with prolonged 1st handgrip relaxation times, and warm up on subsequent handgrips. Sodium channel mutations were associated with prolonged 1st handgrip relaxation times and paradoxical myotonia or warm-up, depending on underlying mutations. DM2 subjects had normal relaxation times but decreased peak force. Sample size estimates are provided for clinical trial planning. Conclusion QMA is an automated, non-invasive technique for evaluating myotonia in NDM. PMID:22987687

  4. Quantitative immunohistochemistry by measuring cumulative signal strength using commercially available software photoshop and matlab.

    Science.gov (United States)

    Matkowskyj, K A; Schonfeld, D; Benya, R V

    2000-02-01

    Currently available techniques for performing quantitative immunohistochemistry (Q-IHC) rely upon pixel-counting algorithms and therefore cannot provide information as to the absolute amount of chromogen present. We describe a novel algorithm for true Q-IHC based on calculating the cumulative signal strength, or energy, of the digital file representing any portion of an image. This algorithm involves subtracting the energy of the digital file encoding the control image (i.e., not exposed to antibody) from that of the experimental image (i.e., antibody-treated). In this manner, the absolute amount of antibody-specific chromogen per pixel can be determined for any cellular region or structure. (J Histochem Cytochem 48:303-311, 2000)

  5. TARGETED, LCMS-BASED METABOLOMICS FOR QUANTITATIVE MEASUREMENT OF NAD+ METABOLITES

    Directory of Open Access Journals (Sweden)

    Samuel AJ Trammell

    2013-01-01

    Full Text Available Nicotinamide adenine dinucleotide (NAD+ is a coenzyme for hydride transfer reactions and a substrate for sirtuins and other NAD+-consuming enzymes. The abundance of NAD+, NAD+ biosynthetic intermediates, and related nucleotides reflects the metabolic state of cells and tissues. High performance liquid chromatography (HPLC followed by ultraviolet-visible (UV-Vis spectroscopic analysis of NAD+ metabolites does not offer the specificity and sensitivity necessary for robust quantification of complex samples. Thus, we developed a targeted, quantitative assay of the NAD+ metabolome with the use of HPLC coupled to mass spectrometry. Here we discuss NAD+ metabolism as well as the technical challenges required for reliable quantification of the NAD+ metabolites. The new method incorporates new separations and improves upon a previously published method that suffered from the problem of ionization suppression for particular compounds.

  6. Intra- and interobserver reliability of quantitative ultrasound measurement of the plantar fascia.

    Science.gov (United States)

    Rathleff, Michael Skovdal; Moelgaard, Carsten; Lykkegaard Olesen, Jens

    2011-01-01

    To determine intra- and interobserver reliability and measurement precision of sonographic assessment of plantar fascia thickness when using one, the mean of two, or the mean of three measurements. Two experienced observers scanned 20 healthy subjects twice with 60 minutes between test and retest. A GE LOGIQe ultrasound scanner was used in the study. The built-in software in the scanner was used to measure the thickness of the plantar fascia (PF). Reliability was calculated using intraclass correlation coefficient (ICC) and limits of agreement (LOA). Intraobserver reliability (ICC) using one measurement was 0.50 for one observer and 0.52 for the other, and using the mean of three measurements intraobserver reliability increased up to 0.77 and 0.67, respectively. Interobserver reliability (ICC) when using one measurement was 0.62 and increased to 0.82 when using the average of three measurements. LOA showed that when using the average of three measurements, LOA decreased to 0.6 mm, corresponding to 17.5% of the mean thickness of the PF. The results showed that reliability increases when using the mean of three measurements compared with one. Limits of agreement based on intratester reliability shows that changes in thickness that are larger than 0.6 mm can be considered actual changes in thickness and not a result of measurement error. Copyright © 2011 Wiley Periodicals, Inc.

  7. Quantitative optical measurement of mitochondrial superoxide dynamics in pulmonary artery endothelial cells

    Directory of Open Access Journals (Sweden)

    Zahra Ghanian

    2018-01-01

    Full Text Available Reactive oxygen species (ROS play a vital role in cell signaling and redox regulation, but when present in excess, lead to numerous pathologies. Detailed quantitative characterization of mitochondrial superoxide anion (O2•− production in fetal pulmonary artery endothelia cells (PAECs has never been reported. The aim of this study is to assess mitochondrial O2•− production in cultured PAECs over time using a novel quantitative optical approach. The rate, the sources, and the dynamics of O2•− production were assessed using targeted metabolic modulators of the mitochondrial electron transport chain (ETC complexes, specifically an uncoupler and inhibitors of the various ETC complexes, and inhibitors of extra-mitochondrial sources of O2•−. After stabilization, the cells were loaded with nanomolar mitochondrial-targeted hydroethidine (Mito-HE, MitoSOX online during the experiment without washout of the residual dye. Time-lapse fluorescence microscopy was used to monitor the dynamic changes in O2•− fluorescence intensity over time in PAECs. The transient behaviors of the fluorescence time course showed exponential increases in the rate of O2•− production in the presence of the ETC uncoupler or inhibitors. The most dramatic and the fastest increase in O2•− production was observed when the cells were treated with the uncoupling agent, PCP. We also showed that only the complex IV inhibitor, KCN, attenuated the marked surge in O2•− production induced by PCP. The results showed that mitochondrial respiratory complexes I, III and IV are sources of O2•− production in PAECs, and a new observation that ROS production during uncoupling of mitochondrial respiration is mediated in part via complex IV. This novel method can be applied in other studies that examine ROS production under stress condition and during ROS-mediated injuries in vitro.

  8. Single-cell quantitative HER2 measurement identifies heterogeneity and distinct subgroups within traditionally defined HER2-positive patients.

    Science.gov (United States)

    Onsum, Matthew D; Geretti, Elena; Paragas, Violette; Kudla, Arthur J; Moulis, Sharon P; Luus, Lia; Wickham, Thomas J; McDonagh, Charlotte F; MacBeath, Gavin; Hendriks, Bart S

    2013-11-01

    Human epidermal growth factor receptor 2 (HER2) is an important biomarker for breast and gastric cancer prognosis and patient treatment decisions. HER2 positivity, as defined by IHC or fluorescent in situ hybridization testing, remains an imprecise predictor of patient response to HER2-targeted therapies. Challenges to correct HER2 assessment and patient stratification include intratumoral heterogeneity, lack of quantitative and/or objective assays, and differences between measuring HER2 amplification at the protein versus gene level. We developed a novel immunofluorescence method for quantitation of HER2 protein expression at the single-cell level on FFPE patient samples. Our assay uses automated image analysis to identify and classify tumor versus non-tumor cells, as well as quantitate the HER2 staining for each tumor cell. The HER2 staining level is converted to HER2 protein expression using a standard cell pellet array stained in parallel with the tissue sample. This approach allows assessment of HER2 expression and heterogeneity within a tissue section at the single-cell level. By using this assay, we identified distinct subgroups of HER2 heterogeneity within traditional definitions of HER2 positivity in both breast and gastric cancers. Quantitative assessment of intratumoral HER2 heterogeneity may offer an opportunity to improve the identification of patients likely to respond to HER2-targeted therapies. The broad applicability of the assay was demonstrated by measuring HER2 expression profiles on multiple tumor types, and on normal and diseased heart tissues. Copyright © 2013 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  9. Psychometric Characteristics of a Measure of Emotional Dispositions Developed to Test a Developmental Propensity Model of Conduct Disorder

    Science.gov (United States)

    Lahey, Benjamin B.; Applegate, Brooks; Chronis, Andrea M.; Jones, Heather A.; Williams, Stephanie Hall; Loney, Jan; Waldman, Irwin D.

    2008-01-01

    Lahey and Waldman proposed a developmental propensity model in which three dimensions of children's emotional dispositions are hypothesized to transact with the environment to influence risk for conduct disorder, heterogeneity in conduct disorder, and comorbidity with other disorders. To prepare for future tests of this model, a new measure of…

  10. An Evaluation of the Reliability and Construct Validity of Eating Disorder Measures in White and Black Women

    Science.gov (United States)

    Kelly, Nichole R.; Mitchell, Karen S.; Gow, Rachel W.; Trace, Sara E.; Lydecker, Janet A.; Bair, Carrie E.; Mazzeo, Suzanne

    2012-01-01

    Most measures of eating disorder symptoms and risk factors were developed in predominantly White female samples. Yet eating disorders affect individuals of all racial and ethnic backgrounds. Black women appear more vulnerable to certain forms of eating pathology, such as binge eating, and less susceptible to other eating disorder symptoms and risk…

  11. Volume measurement of the leg with the depth camera for quantitative evaluation of edema

    Science.gov (United States)

    Kiyomitsu, Kaoru; Kakinuma, Akihiro; Takahashi, Hiroshi; Kamijo, Naohiro; Ogawa, Keiko; Tsumura, Norimichi

    2017-02-01

    Volume measurement of the leg is important in the evaluation of leg edema. Recently, method for measurement by using a depth camera is proposed. However, many depth cameras are expensive. Therefore, we propose a method using Microsoft Kinect. We obtain a point cloud of the leg by Kinect Fusion technique and calculate the volume. We measured the volume of leg for three healthy students during three days. In each measurement, the increase of volume was confirmed from morning to evening. It is known that the volume of leg is increased in doing office work. Our experimental results meet this expectation.

  12. Quantitative Assessment of the Impact of Blood Pulsation on Intraocular Pressure Measurement Results in Healthy Subjects

    Directory of Open Access Journals (Sweden)

    Robert Koprowski

    2017-01-01

    Full Text Available Background. Blood pulsation affects the results obtained using various medical devices in many different ways. Method. The paper proves the effect of blood pulsation on intraocular pressure measurements. Six measurements for each of the 10 healthy subjects were performed in various phases of blood pulsation. A total of 8400 corneal deformation images were recorded. The results of intraocular pressure measurements were related to the results of heartbeat phases measured with a pulse oximeter placed on the index finger of the subject’s left hand. Results. The correlation between the heartbeat phase measured with a pulse oximeter and intraocular pressure is 0.69±0.26 (p<0.05. The phase shift calculated for the maximum correlation is equal to 60±40° (p<0.05. When the moment of measuring intraocular pressure with an air-puff tonometer is not synchronized, the changes in IOP for the analysed group of subjects can vary in the range of ±2.31 mmHg (p<0.3. Conclusions. Blood pulsation has a statistically significant effect on the results of intraocular pressure measurement. For this reason, in modern ophthalmic devices, the measurement should be synchronized with the heartbeat phases. The paper proposes an additional method for synchronizing the time of pressure measurement with the blood pulsation phase.

  13. Quantitative measurement of pathogen specific human memory T cell repertoire diversity using a CDR3β-specific microarray

    Directory of Open Access Journals (Sweden)

    Gorski Jack

    2007-09-01

    Full Text Available Abstract Background Providing quantitative microarray data that is sensitive to very small differences in target sequence would be a useful tool in any number of venues where a sample can consist of a multiple related sequences present in various abundances. Examples of such applications would include measurement of pseudo species in viral infections and the measurement of species of antibodies or T cell receptors that constitute immune repertoires. Difficulties that must be overcome in such a method would be to account for cross-hybridization and for differences in hybridization efficiencies between the arrayed probes and their corresponding targets. We have used the memory T cell repertoire to an influenza-derived peptide as a test case for developing such a method. Results The arrayed probes were corresponded to a 17 nucleotide TCR-specific region that distinguished sequences differing by as little as a single nucleotide. Hybridization efficiency between highly related Cy5-labeled subject sequences was normalized by including an equimolar mixture of Cy3-labeled synthetic targets representing all 108 arrayed probes. The same synthetic targets were used to measure the degree of cross hybridization between probes. Reconstitution studies found the system sensitive to input ratios as low as 0.5% and accurate in measuring known input percentages (R2 = 0.81, R = 0.90, p 0.05. Conclusion This novel strategy appears to be robust and can be adapted to any situation where complex mixtures of highly similar sequences need to be quantitatively resolved.

  14. Quantitation of specific myeloid cells in rat bone marrow measured by in vitro /sup 35/S-sulphate incorporation

    Energy Technology Data Exchange (ETDEWEB)

    Wright, A F; Rose, M S

    1984-08-01

    A biochemical measurement which can be used for quantitation of specific early myeloid cells in rat bone marrow has been developed. This measurement consists of a rapid, simple assay for the in vitro quantitation of /sup 35/S-sulfate incorporation into rat bone marrow cells. Incubation of bone marrow cells with /sup 35/S-sulfate led to a time-dependent increase in radioactivity obtained in perchloric acid insoluble fractions of bone marrow cell suspensions. This incorporation was inhibited by cyanide and puromycin. Autoradiography has demonstrated the radiolabel to be specifically associated with immature cells of the myeloid series. The cells most active in this respect were eosinophils. When rats were treated with endotoxin, the rate of /sup 35/S-sulfate incorporation was increased. Cell number measurements, using conventional histopathology and a Coulter Counter, demonstrated that endotoxin caused an initial release of mature granulocytes from the bone marrow. The regeneration of this mature population in the marrow was rapid, and was characterized by an increase in the number of immature cells and a concomitant increase in the rate of /sup 35/S-sulfate incorporation measured in preparations of bone marrow cells in vitro. Furthermore, this response to endotoxin has demonstrated that Coulter Counting techniques can be used to distinguish specific populations of cells (e.g. mature granulocytes) within the bone marrow.

  15. Systematic review of tools to measure outcomes for young children with autism spectrum disorder

    NARCIS (Netherlands)

    McConachie, H.; Parr, J.R.; Glod, M.; Hanratty, J.; Livingstone, N.; Oono, I.P.; Robalino, S.; Baird, G.; Beresford, B.; Charman, T.; Garland, D.; Green, J.; Gringras, P.; Jones, G.; Law, J.; Le Couteur, A.S.; Macdonald, G.; McColl, E.M.; Morris, C.; Rodgers, J.; Simonoff, E.; Terwee, C.B.; Williams, K.

    2015-01-01

    Background: The needs of children with autism spectrum disorder (ASD) are complex and this is reflected in the number and diversity of outcomes assessed and measurement tools used to collect evidence about children�s progress. Relevant outcomes include improvement in core ASD impairments, such as

  16. Exploring Continuity of Care in Patients with Alcohol Use Disorders Using Time-Variant Measures

    NARCIS (Netherlands)

    S.C. de Vries (Sjoerd); A.I. Wierdsma (André)

    2008-01-01

    textabstractBackground/Aims: We used time-variant measures of continuity of care to study fluctuations in long-term treatment use by patients with alcohol-related disorders. Methods: Data on service use were extracted from the Psychiatric Case Register for the Rotterdam Region, The Netherlands.

  17. Measuring Reciprocity in High Functioning Children and Adolescents with Autism Spectrum Disorders

    Science.gov (United States)

    van Ommeren, Tineke Backer; Begeer, Sander; Scheeren, Anke M.; Koot, Hans M.

    2012-01-01

    Few instruments have been developed that measure impairments in reciprocity, a defining feature of autism. We introduce a new test assessing the quality of reciprocal behaviour: the interactive drawing test (IDT). Children and adolescents (n = 49) with and without high functioning autism spectrum disorders (HFASD) were invited to collaborate with…

  18. Actual interaction effects between policy measures for energy efficiency-A qualitative matrix method and quantitative simulation results for households

    International Nuclear Information System (INIS)

    Boonekamp, Piet G.M.

    2006-01-01

    Starting from the conditions for a successful implementation of saving options, a general framework was developed to investigate possible interaction effects in sets of energy policy measures. Interaction regards the influence of one measure on the energy saving effect of another measure. The method delivers a matrix for all combinations of measures, with each cell containing qualitative information on the strength and type of interaction: overlapping, reinforcing, or independent of each other. Results are presented for the set of policy measures on household energy efficiency in the Netherlands for 1990-2003. The second part regards a quantitative analysis of the interaction effects between three major measures: a regulatory energy tax, investment subsidies and regulation of gas use for space heating. Using a detailed bottom-up model, household energy use in the period 1990-2000 was simulated with and without these measures. The results indicate that combinations of two or three policy measures yield 13-30% less effect than the sum of the effects of the separate measures

  19. Quantitative measurements of magnetic polaron binding on acceptors in CdMnTe alloys

    Science.gov (United States)

    Nhung, Tran Hong; Planel, R.

    1983-03-01

    The acceptor binding energy is measured as a function of Temperature and composition in Cd1-x Mnx Te alloys, by time resolved spectroscopy. The Bound magnetic polaron effect is measured and compared with a theory accouting for magnetic saturation and fluctuations.

  20. Assessment of a portable device for the quantitative measurement of ankle joint stiffness in spastic individuals

    DEFF Research Database (Denmark)

    Lorentzen, Jakob; Grey, Michael J; Geertsen, Svend Sparre

    2012-01-01

    was measured with the portable device and a stationary torque motor. Inter- and intra-rater reliability was assessed with the intra-class correlation coefficient (ICC). RESULTS: Stiffness measures with the portable and stationary devices were significantly correlated for controls and MS participants (p...

  1. Quantitative comparison of in situ soil CO2 flux measurement methods

    Science.gov (United States)

    Jennifer D. Knoepp; James M. Vose

    2002-01-01

    Development of reliable regional or global carbon budgets requires accurate measurement of soil CO2 flux. We conducted laboratory and field studies to determine the accuracy and comparability of methods commonly used to measure in situ soil CO2 fluxes. Methods compared included CO2...

  2. Quantitation of the degree of osteoporosis by measure of total-body calcium employing neutron activation

    International Nuclear Information System (INIS)

    Cohn, S.H.; Zanzi, I.; Vaswani, A.; Wallach, S.; Aloia, J.; Ellis, K.J.

    1975-01-01

    Two techniques for measuring the amount of Ca in the total skeleton were employed: total-body neutron activation analysis (TBNAA) and the determination of the mineral content of a bone of the appendicular skeleton (absorptiometric measurement of the radius, BMC). (U.S.)

  3. Observation of Spontaneous Expressive Language (OSEL): A New Measure for Spontaneous and Expressive Language of Children with Autism Spectrum Disorders and Other Communication Disorders

    Science.gov (United States)

    Kim, So Hyun; Junker, Dörte; Lord, Catherine

    2014-01-01

    A new language measure, the Observation of Spontaneous Expressive Language (OSEL), is intended to document spontaneous use of syntax, pragmatics, and semantics in 2-12-year-old children with Autism Spectrum Disorder (ASD) and other communication disorders with expressive language levels comparable to typical 2-5 year olds. Because the purpose of…

  4. Quantitative echocardiographic measures in the assessment of single ventricle function post-Fontan: Incorporation into routine clinical practice.

    Science.gov (United States)

    Rios, Rodrigo; Ginde, Salil; Saudek, David; Loomba, Rohit S; Stelter, Jessica; Frommelt, Peter

    2017-01-01

    Quantitative echocardiographic measurements of single ventricular (SV) function have not been incorporated into routine clinical practice. A clinical protocol, which included quantitative measurements of SV deformation (global circumferential and longitudinal strain and strain rate), standard deviation of time to peak systolic strain, myocardial performance index (MPI), dP/dT from an atrioventricular valve regurgitant jet, and superior mesenteric artery resistance index, was instituted for all patients with a history of Fontan procedure undergoing echocardiography. All measures were performed real time during clinically indicated studies and were included in clinical reports. A total of 100 consecutive patients (mean age = 11.95±6.8 years, range 17 months-31.3 years) completed the protocol between September 1, 2014 to April 29, 2015. Deformation measures were completed in 100% of the studies, MPI in 93%, dP/dT in 55%, and superior mesenteric artery Doppler in 82%. The studies were reviewed to assess for efficiency in completing the protocol. The average time for image acquisition was 27.4±8.8 (range 10-62 minutes). The average time to perform deformation measures was 10.8±5.5 minutes (range 5-35 minutes) and time from beginning of imaging to report completion was 53.4±13.7 minutes (range 27-107 minutes). There was excellent inter-observer reliability when deformation indices were blindly repeated. Patients with a single left ventricle had significantly higher circumferential strain and strain rate, longitudinal strain and strain rate, and dP/dT compared to a single right ventricle. There were no differences in quantitative indices of ventricular function between patients 10 years post-Fontan. Advanced quantitative assessment of SV function post-Fontan can be consistently and efficiently performed real time during clinically indicated echocardiograms with excellent reliability. © 2016, Wiley Periodicals, Inc.

  5. Tear clearance measurement in patients with dry eye syndrome using quantitative lacrimal scintigraphy

    International Nuclear Information System (INIS)

    Gencoglu, E.A.; Dursun, D.; Akova, Y.A.; Cengiz, F.; Yalcin, H.; Koyuncu, A.

    2005-01-01

    The aim of this study was to evaluate the tear clearance in patients with dry eye syndrome using quantitative lacrimal scintigraphy. We investigated 21 patients (42 eyes; 18 women, 3 men; mean age, 63.19±13.33 years) with dry eye syndrome. Additionally, for the sake of comparison, 12 normal subjects of the same age group (24 eyes; 10 women, 2 men; mean age, 68.25±2.63 years) were included. Lacrimal scintigraphy, Schirmer-1 test, break-up time (BUT), and rose bengal ocular surface vital staining were performed in these cases. According to the results of lacrimal scintigraphy, the mean value of T1/2 was 4.16±1.22 minutes and the mean value of radioisotope (RI) was 14.15%±2.30% in normal subjects. However, in patients with dry eye syndrome, these values were 20.59±1.97 minutes and 55.64%±6.90%, respectively. Consistent with the results of ophthalmologic tests, the mean Schirmer-1 value was 12.46±2.10 mm, the mean value of BUT was 14.36±3.40 seconds, and the mean staining value of the rose bengal was 1.98±0.80 in normal subjects, whereas these values were 1.36±0.49 mm, 5.46±1.33 seconds, 6.62±0.86, respectively, in patients with dry eye syndrome. When we compared the results of lacrimal scintigraphy and the results of ophthalmologic tests, an inverse correlation was noted between both the T1/2 and RI values and both the Schirmer-1 and BUT values in all subjects (p<0.001). However, there was a greater positive correlation between the rose bengal ocular surface staining value and both the T1/2 and RI values in all cases (p<0.001). In the current study, it was concluded that although the lacrimal drainage system was normal, tear clearance was significantly delayed in dry eye patients. With this study, we have shown that quantitative lacrimal scintigraphy, which is an objective, practical, and noninvasive method, appears to be useful for the assessment of the tear clearance in patients with dry eye syndrome. (author)

  6. Qualitative and quantitative measurement of human brain activity using pixel subtraction algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jin Myoung; Jeong, Gwang Woo; Kim, Hyung Joong; Cho, Seong Hoon; Kang, Heoung Keun; Seo, Jeong Jin; Park, Seung Jin [School of Medicine, Chonnam National Univ., Kwangju (Korea, Republic of)

    2004-08-01

    manual quantification method showed an average error of 0.334{+-}0.007 (%). Thus, the manual counting method gave less accurate quantitative information on brain activation than the FALBA program. The FALBA program is capable of providing accurate quantitative results, including the identification of the brain activation region and lateralization index with respect to the functional and anatomical areas. Also, the processing time was dramatically shortened in comparison with the manual counting method.

  7. Qualitative and quantitative measurement of human brain activity using pixel subtraction algorithm

    International Nuclear Information System (INIS)

    Lee, Jin Myoung; Jeong, Gwang Woo; Kim, Hyung Joong; Cho, Seong Hoon; Kang, Heoung Keun; Seo, Jeong Jin; Park, Seung Jin

    2004-01-01

    quantification method showed an average error of 0.334±0.007 (%). Thus, the manual counting method gave less accurate quantitative information on brain activation than the FALBA program. The FALBA program is capable of providing accurate quantitative results, including the identification of the brain activation region and lateralization index with respect to the functional and anatomical areas. Also, the processing time was dramatically shortened in comparison with the manual counting method

  8. Methods for quantitative infrared directional-hemispherical and diffuse reflectance measurements using an FTIR and a commercial integrating sphere

    Energy Technology Data Exchange (ETDEWEB)

    Blake, Thomas A.; Johnson, Timothy J.; Tonkyn, Russell G.; Forland, Brenda M.; Myers, Tanya L.; Brauer, Carolyn S.; Su, Yin-Fong; Bernacki, Bruce E.; Hanssen, Leonard; Gonzalez, Gerardo

    2018-01-01

    Infrared integrating sphere measurements of solid samples are important in providing reference data for contact, standoff and remote sensing applications. At the Pacific Northwest National Laboratory (PNNL) we have developed protocols to measure both the directional-hemispherical ( and diffuse (d) reflectances of powders, liquids, and disks of powders and solid materials using a commercially available, matte gold-coated integrating sphere and Fourier transform infrared spectrometer. Detailed descriptions of the sphere alignment and its use for making these reflectance measurements are given. Diffuse reflectance values were found to be dependent on the bidirectional reflection distribution function (BRDF) of the sample and the solid angle intercepted by the sphere’s specular exclusion port. To determine how well the sphere and protocols produce quantitative reflectance data, measurements were made of three diffuse and two specular standards prepared by the National institute of Standards and Technology (NIST, USA), LabSphere Infragold and Spectralon standards, hand-loaded sulfur and talc powder samples, and water. The five NIST standards behaved as expected: the three diffuse standards had a high degree of “diffuseness,” d/ = D > 0.9, whereas the two specular standards had D ≤ 0.03. The average absolute differences between the NIST and PNNL measurements of the NIST standards for both directional-hemispherical and diffuse reflectances are on the order of 0.01 reflectance units. Other quantitative differences between the PNNL-measured and calibration (where available) or literature reflectance values for these standards and materials are given and the possible origins of discrepancies are discussed. Random uncertainties and estimates of systematic uncertainties are presented. Corrections necessary to provide better agreement between the PNNL reflectance values as measured for the NIST standards and the NIST reflectance values for these same standards are also

  9. Quantitative skin color measurements in acanthosis nigricans patients: colorimetry and diffuse reflectance spectroscopy.

    Science.gov (United States)

    Pattamadilok, Bensachee; Devpura, Suneetha; Syed, Zain U; Agbai, Oma N; Vemulapalli, Pranita; Henderson, Marsha; Rehse, Steven J; Mahmoud, Bassel H; Lim, Henry W; Naik, Ratna; Hamzavi, Iltefat H

    2012-08-01

    Tristimulus colorimetry and diffuse reflectance spectroscopy (DRS) are white-light skin reflectance techniques used to measure the intensity of skin pigmentation. The tristimulus colorimeter is an instrument that measures a perceived color and the DRS instrument measures biological chromophores of the skin, including oxy- and deoxyhemoglobin, melanin and scattering. Data gathered from these tools can be used to understand morphological changes induced in skin chromophores due to conditions of the skin or their treatments. The purpose of this study was to evaluate the use of these two instruments in color measurements of acanthosis nigricans (AN) lesions. Eight patients with hyperinsulinemia and clinically diagnosable AN were seen monthly. Skin pigmentation was measured at three sites: the inner forearm, the medial aspect of the posterior neck, and anterior neck unaffected by AN. Of the three, measured tristimulus L*a*b* color parameters, the luminosity parameter L* was found to most reliably distinguish lesion from normally pigmented skin. The DRS instrument was able to characterize a lesion on the basis of the calculated melanin concentration, though melanin is a weak indicator of skin change and not a reliable measure to be used independently. Calculated oxyhemoglobin and deoxyhemoglobin concentrations were not found to be reliable indicators of AN. Tristimulus colorimetry may provide reliable methods for respectively quantifying and characterizing the objective color change in AN, while DRS may be useful in characterizing changes in skin melanin content associated with this skin condition. © 2012 John Wiley & Sons A/S.

  10. Quantitative assessment of skin erythema due to radiotherapy--evaluation of different measurements

    International Nuclear Information System (INIS)

    Wengstroem, Yvonne; Forsberg, Christina; Naeslund, Ingemar; Bergh, Jonas

    2004-01-01

    Background and purpose: Visual assessment is the most common clinical investigation of skin reactions in radiotherapy. Due to the unquantitative and subjective nature of this method additional non-invasive methods are needed for more accurate evaluation of the visible acute adverse skin reactions due to radiotherapy. The purpose of this study was to evaluate a new objective measure with regard to reliability and validity and compare it with an established objective measure and a visual assessment. Patients and methods: A sample of 53 consecutive patients commencing curative tangential radiation therapy to the breast parenchyma were included in the study. The skin area of the treated breast was divided into five sections and assessed individually at 0, 24 and 50 Gy. The RTOG scoring system was used for the visual assessment of the skin reactions. The first objective measure included reflectance spectrometry (DermaSpectrometer) measures at fixed points within the treatment area. For the second objective measure digital images (Camera) were taken with a system using a digital camera and software. The images were analyzed using the Adobe Photoshop 5.0 software program. Results: The results provided significant evidence of the test-retest reliability of the camera. The correlation between the objective measures proved to be significant as the treatment progressed. Conclusions: The results suggest that the camera may be used in a reliable and valid way to measure skin erythema due to radiotherapy

  11. Correlation Between Acoustic Measurements and Self-Reported Voice Disorders Among Female Teachers.

    Science.gov (United States)

    Lin, Feng-Chuan; Chen, Sheng Hwa; Chen, Su-Chiu; Wang, Chi-Te; Kuo, Yu-Ching

    2016-07-01

    Many studies focused on teachers' voice problems and most of them were conducted using questionnaires, whereas little research has investigated the relationship between self-reported voice disorders and objective quantification of voice. This study intends to explore the relationship of acoustic measurements according to self-reported symptoms and its predictive value of future dysphonia. This is a case-control study. Voice samples of 80 female teachers were analyzed, including 40 self-reported voice disorders (VD) and 40 self-reported normal voice (NVD) subjects. The acoustic measurements included jitter, shimmer, and noise-to-harmonics ratio (NHR). Levene's t test and logistic regression were used to analyze the differences between VD and NVD and the relationship between self-reported voice conditions and the acoustic measurements. To examine whether acoustic measurements can be used to predict further voice disorders, we applied a receiver operating characteristic (ROC) curve to determine the cutoff values and the associated sensitivity and specificity. The results showed that jitter, shimmer, and the NHR of VD were significantly higher than those of NVD. Among the parameters, the NHR and shimmer demonstrated the highest correlation with self-reported voice disorders. By using the NHR ≥0.138 and shimmer ≥0.470 dB as the cutoff values, the ROC curve displayed 72.5% of sensitivity and 75% of specificity, and the overall positive predictive value for subsequent dysphonia achieved 60%. This study demonstrated a significant correlation between acoustic measurements and self-reported dysphonic symptoms. NHR and ShdB are two acoustic parameters that are more able to reflect vocal abnormalities and, probably, to predict subsequent subjective voice disorder. Future research recruiting more subjects in other occupations and genders shall validate the preliminary results revealed in this study. Copyright © 2016 The Voice Foundation. Published by Elsevier Inc. All

  12. Generalized procedures for determining inspection sample sizes (related to quantitative measurements). Vol. 1: Detailed explanations

    International Nuclear Information System (INIS)

    Jaech, J.L.; Lemaire, R.J.

    1986-11-01

    Generalized procedures have been developed to determine sample sizes in connection with the planning of inspection activities. These procedures are based on different measurement methods. They are applied mainly to Bulk Handling Facilities and Physical Inventory Verifications. The present report attempts (i) to assign to appropriate statistical testers (viz. testers for gross, partial and small defects) the measurement methods to be used, and (ii) to associate the measurement uncertainties with the sample sizes required for verification. Working papers are also provided to assist in the application of the procedures. This volume contains the detailed explanations concerning the above mentioned procedures

  13. Listening to light scattering in turbid media: quantitative optical scattering imaging using photoacoustic measurements with one-wavelength illumination

    International Nuclear Information System (INIS)

    Yuan, Zhen; Li, Xiaoqi; Xi, Lei

    2014-01-01

    Biomedical photoacoustic tomography (PAT), as a potential imaging modality, can visualize tissue structure and function with high spatial resolution and excellent optical contrast. It is widely recognized that the ability of quantitatively imaging optical absorption and scattering coefficients from photoacoustic measurements is essential before PAT can become a powerful imaging modality. Existing quantitative PAT (qPAT), while successful, has been focused on recovering absorption coefficient only by assuming scattering coefficient a constant. An effective method for photoacoustically recovering optical scattering coefficient is presently not available. Here we propose and experimentally validate such a method for quantitative scattering coefficient imaging using photoacoustic data from one-wavelength illumination. The reconstruction method developed combines conventional PAT with the photon diffusion equation in a novel way to realize the recovery of scattering coefficient. We demonstrate the method using various objects having scattering contrast only or both absorption and scattering contrasts embedded in turbid media. The listening-to-light-scattering method described will be able to provide high resolution scattering imaging for various biomedical applications ranging from breast to brain imaging. (papers)

  14. Sustainable Urban Forestry Potential Based Quantitative And Qualitative Measurement Using Geospatial Technique

    Science.gov (United States)

    Rosli, A. Z.; Reba, M. N. M.; Roslan, N.; Room, M. H. M.

    2014-02-01

    In order to maintain the stability of natural ecosystems around urban areas, urban forestry will be the best initiative to maintain and control green space in our country. Integration between remote sensing (RS) and geospatial information system (GIS) serves as an effective tool for monitoring environmental changes and planning, managing and developing a sustainable urbanization. This paper aims to assess capability of the integration of RS and GIS to provide information for urban forest potential sites based on qualitative and quantitative by using priority parameter ranking in the new township of Nusajaya. SPOT image was used to provide high spatial accuracy while map of topography, landuse, soils group, hydrology, Digital Elevation Model (DEM) and soil series data were applied to enhance the satellite image in detecting and locating present attributes and features on the ground. Multi-Criteria Decision Making (MCDM) technique provides structural and pair wise quantification and comparison elements and criteria for priority ranking for urban forestry purpose. Slope, soil texture, drainage, spatial area, availability of natural resource, and vicinity of urban area are criteria considered in this study. This study highlighted the priority ranking MCDM is cost effective tool for decision-making in urban forestry planning and landscaping.

  15. Sustainable Urban Forestry Potential Based Quantitative And Qualitative Measurement Using Geospatial Technique

    International Nuclear Information System (INIS)

    Rosli, A Z; Reba, M N M; Roslan, N; Room, M H M

    2014-01-01

    In order to maintain the stability of natural ecosystems around urban areas, urban forestry will be the best initiative to maintain and control green space in our country. Integration between remote sensing (RS) and geospatial information system (GIS) serves as an effective tool for monitoring environmental changes and planning, managing and developing a sustainable urbanization. This paper aims to assess capability of the integration of RS and GIS to provide information for urban forest potential sites based on qualitative and quantitative by using priority parameter ranking in the new township of Nusajaya. SPOT image was used to provide high spatial accuracy while map of topography, landuse, soils group, hydrology, Digital Elevation Model (DEM) and soil series data were applied to enhance the satellite image in detecting and locating present attributes and features on the ground. Multi-Criteria Decision Making (MCDM) technique provides structural and pair wise quantification and comparison elements and criteria for priority ranking for urban forestry purpose. Slope, soil texture, drainage, spatial area, availability of natural resource, and vicinity of urban area are criteria considered in this study. This study highlighted the priority ranking MCDM is cost effective tool for decision-making in urban forestry planning and landscaping

  16. Quantitative gait measurement with pulse-Doppler radar for passive in-home gait assessment.

    Science.gov (United States)

    Wang, Fang; Skubic, Marjorie; Rantz, Marilyn; Cuddihy, Paul E

    2014-09-01

    In this paper, we propose a pulse-Doppler radar system for in-home gait assessment of older adults. A methodology has been developed to extract gait parameters including walking speed and step time using Doppler radar. The gait parameters have been validated with a Vicon motion capture system in the lab with 13 participants and 158 test runs. The study revealed that for an optimal step recognition and walking speed estimation, a dual radar set up with one radar placed at foot level and the other at torso level is necessary. An excellent absolute agreement with intraclass correlation coefficients of 0.97 was found for step time estimation with the foot level radar. For walking speed, although both radars show excellent consistency they all have a system offset compared to the ground truth due to walking direction with respect to the radar beam. The torso level radar has a better performance (9% offset on average) in the speed estimation compared to the foot level radar (13%-18% offset). Quantitative analysis has been performed to compute the angles causing the systematic error. These lab results demonstrate the capability of the system to be used as a daily gait assessment tool in home environments, useful for fall risk assessment and other health care applications. The system is currently being tested in an unstructured home environment.

  17. Quantitative measurement of XLR11 and UR-144 in oral fluid by LC-MS-MS.

    Science.gov (United States)

    Amaratunga, Piyadarsha; Thomas, Christopher; Lemberg, Bridget Lorenz; Lemberg, Dave

    2014-01-01

    Availability and consumption of synthetic cannabinoids have risen recently in the USA and Europe. These drugs have adverse effects, including acute psychosis and bizarre behavior. In 2012, the United States Drug Enforcement Agency permanently banned five of the synthetic cannabinoids and in 2013, temporarily added XLR11, UR-144 and AKB48 to Schedule I of the Controlled Substances Act. As synthetic cannabinoid strains are added to the Schedule I list, new strains are being introduced into the market. XLR11 and UR-144 are two of the most recent additions to the synthetic cannabinoid drug class. To test collected oral fluid samples for XLR11 and UR-144, we developed a bioanalytical method that initially purifies the sample with solid-phase extraction and then quantitatively identifies the drugs with ultra-high-performance liquid chromatography-tandem mass spectrometry. The method was validated according to United States Food and Drug Administration guidelines and Scientific Working Group for Forensic Toxicology guidelines and the validation data showed that the method is an accurate, precise, robust and efficient method suited for high-throughput toxicological screening applications. We tested human subject samples with the developed method and found the presence of parent drugs (XLR11 and UR-144), their metabolites and their pyrolysis products in oral fluid. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. A quantitative measure for degree of automation and its relation to system performance and mental load.

    Science.gov (United States)

    Wei, Z G; Macwan, A P; Wieringa, P A

    1998-06-01

    In this paper we quantitatively model degree of automation (DofA) in supervisory control as a function of the number and nature of tasks to be performed by the operator and automation. This model uses a task weighting scheme in which weighting factors are obtained from task demand load, task mental load, and task effect on system performance. The computation of DofA is demonstrated using an experimental system. Based on controlled experiments using operators, analyses of the task effect on system performance, the prediction and assessment of task demand load, and the prediction of mental load were performed. Each experiment had a different DofA. The effect of a change in DofA on system performance and mental load was investigated. It was found that system performance became less sensitive to changes in DofA at higher levels of DofA. The experimental data showed that when the operator controlled a partly automated system, perceived mental load could be predicted from the task mental load for each task component, as calculated by analyzing a situation in which all tasks were manually controlled. Actual or potential applications of this research include a methodology to balance and optimize the automation of complex industrial systems.

  19. Morphologic characterization and quantitative analysis on in vitro bacteria by nuclear techniques of measurement

    International Nuclear Information System (INIS)

    Lopes, Joana D'Arc Ramos

    2001-10-01

    The great difficulty to identify microorganisms (bacteria) from infectious processes is related to the necessary time to obtain a reliable result, about 72 hours. The purpose of this work is to establish a faster method to characterize bacterial morphologies through the use of neutron radiography, which can take about 5 hours. The samples containing the microorganisms, bacteria with different morphologies, after the appropriate microbiologic procedures were incubated with B 10 for 30 minutes and soon after deposited in a plate of a solid detector of nuclear tracks (SSNTD), denominated CR-39. To obtain the images relative to bacteria, the detector was submitted to the flow of thermal neutrons of the order of 2.2 x 10 5 n/cm 2 .s from the J-9 channel of the Reactor Argonauta (IEN/CNEN). To observe the images from bacteria in each sample under an optical microscope, the sheets were chemically developed. The analysis of the images revealed morphologic differences among the genera (Gram positive from Gram-negative and coccus from bacillus), in samples containing either isolated or mixed bacteria. We thus verified the viability of the technique to achieve morphological characterization of different microorganisms. A quantitative approach seemed also to be feasible with the technique. The whole process took about 2 hours. (author)

  20. An improved quantitative measurement for thyroid cancer detection based on elastography

    International Nuclear Information System (INIS)

    Ding Jianrui; Cheng, H.D.; Huang Jianhua; Zhang Yingtao; Liu Jiafeng

    2012-01-01

    Objective: To evaluate color thyroid elastograms quantitatively and objectively. Materials and methods: 125 cases (56 malignant and 69 benign) were collected with the HITACHI Vision 900 system (Hitachi Medical System, Tokyo, Japan) and a liner-array-transducer of 6–13 MHz. Standard of reference was cytology (FNA—fine needle aspiration) or histology (core biopsy). The original color thyroid elastograms were transferred from red, green, blue (RGB) color space to hue, saturation, value (HSV) color space. Then, hard area ratio was defined. Finally, a SVM classifier was used to classify thyroid nodules into benign and malignant. The relation between the performance and hard threshold was fully investigated and studied. Results: The classification accuracy changed with the hard threshold, and reached maximum (95.2%) at some values (from 144 to 152). It was higher than strain ratio (87.2%) and color score (83.2%). It was also higher than the one of our previous study (93.6%). Conclusion: The hard area ratio is an important feature of elastogram, and appropriately selected hard threshold can improve classification accuracy.

  1. Quantitative measurement of bone mineral contents in patients with senile osteoporosis and chronic renal failure

    International Nuclear Information System (INIS)

    Fukuda, Teruo

    1985-01-01

    Computed tomography using X-ray (XCT) and single photon emission computed tomography (SPECT) using sup(99m)Tc-MDP of the skull were performed in patients with ''senile osteoporosis'' and with chronic renal failure, in order to quantitatively determine bone mineral contents. XCT: In females with postmenopausal osteoporosis (6th decade), the EMI number of frontal bone was significantly low compared with that of control group, of the same age. The EMI number in ''senile osteoporosis'' correlated with the value of serum 25 (OH) D and 1 α - 25 (OH) 2 D. The EMI number in hemodialyzed patients was significantly low compared with that in the control group. On the other hand, the EMI number in non-hemodialyzed chronic renal failure patients showed no significant difference compared with findings in the control group. The EMI number of the frontal bone in patients with partial parathyroidectomy showed a slight rise compared with findings before surgery. Bone scintigram, Bone scan SPECT: Positive scan was seen in patients with long term hemodialysis and increased values of serum Alk-Pase and PTH were often apparent. Scintigraphic improvement in patients with renal osteodystrophy treated with vitamin D 3 showed a good correlation with improvement in serum Alk-Pase values. On SPECT, frontal bone activity in patients with renal osteodystrophy was significantly high compared with that in the control group. In case of renal osteodystrophy treated with partial parathyroidectomy, the frontal bone activity was markedly decreased compared with findings before surgery. (J.P.N.)

  2. Software Process Validation: Quantitatively Measuring the Correspondence of a Process to a Model

    National Research Council Canada - National Science Library

    Cook, Jonathan E; Wolf, Alexander L

    1997-01-01

    .... When process models and process executions diverge, something significant is happening. The authors have developed techniques for uncovering and measuring the discrepancies between models and executions, which they call process validation...

  3. Quantitative research regarding performance measures for intermodal freight transportation : executive summary

    Science.gov (United States)

    1995-10-01

    The primary objective of this study is to provide information relative to the development of a set of performance measures for intermodal freight transportation. To accomplish this objective, data was collected, processed, and analyzed on the basis o...

  4. Measurement system microdensitometer Joyce-Loebl and computer IBM-PC for quantitative evaluation of autoradiograms

    International Nuclear Information System (INIS)

    Chajecki, T.

    1992-01-01

    The description of measurement system microdensitometer Joyce-Loebl, computer IBM-PC interface are given in the report. This system gives the possibility to save and processing of autoradiograms quantity data. (author). 2 refs, 14 figs, 2 tabs

  5. Quantitative radioisotope measurements with the NSF-Arizona regional accelerator facility

    International Nuclear Information System (INIS)

    Zabel, T.H.; Damon, P.E.; Donahue, D.J.; Jull, A.J.T.

    1983-01-01

    Results of tests on the tandem accelerator mass spectrometer (TAMS) at the University of Arizona are presented. These results demonstrate: (a) measurements of 14 C/ 13 C ratios with precisions of a few percent can be made in a period of one to several hours; (b) measurements with precisions of 0.5% have been made in which the uncertainties were mainly statistical and in which contributions to the uncertainty of machine fluctuations were negligible; (c) precise measurements of the ratio of 14 C/ 13 C in samples of N.B.S. oxalic acid and of 1890 wood are consistent with the accepted value of that ratio; (d) the real signal from a 44,000 year old sample is equal to the background rate produced from a dead carbon sample. In addition, results of some measurements on archaeological samples are presented

  6. Quantitative assessment of motor functions post-stroke: Responsiveness of upper-extremity robotic measures and its task dependence.

    Science.gov (United States)

    Hussain, Asif; Budhota, Aamani; Contu, Sara; Kager, Simone; Vishwanath, Deshmukh A; Kuah, Christopher W K; Yam, Lester H L; Chua, Karen S G; Masia, Lorenzo; Campolo, Domenico

    2017-07-01

    Technology aided measures offer a sensitive, accurate and time-efflcient approach for the assessment of sensorimotor function after neurological impairment compared to standard clinical assessments. This preliminary study investigated the relationship between task definition and its effect on robotic measures using a planar, two degree of freedom, robotic-manipulator (H-Man). Four chronic stroke participants (49.5±11.95 years, 2 Female, FMA: 37.5±13.96) and eight healthy control participants (26.25± 4.70 years, 2 Female) participated in the study. Motor functions were evaluated using line tracing and circle tracing tasks with dominant and nondominant hand of healthy and affected vs. non affected hand of stroke participants. The results show significant dependence of quantitative measures on investigated tasks.

  7. A quantitative method for measurement of lysosomal acid phosphatase latency in cultured rat heart cells with 210Pb

    International Nuclear Information System (INIS)

    Hale, T.W.; Wenzel, D.G.

    1978-01-01

    A method is described for measuring the latency of lysomal acid phosphatase in cultured rat heart endotheloid cells. 210 Pb was added to a medium used to demonstrate acid phosphatase activity by the Gomori lead method, and the amount of lead deposited was measured with a liquid scintillation counter. Deposition rates were measured after enzyme activation pretreatments with acetate buffer (pH 5.0) at various osmolalities, and after formaldehyde fixation. Formaldehyde, alloxan, or fluoride in the Gomori medium were evaluated for their differential effects on lysosomal and non-lysosomal acid phosphatase The method was found to provide a sensitive, rapid and quantitative evaluation of acid phosphatase latency and should be useful for studying the integrity of lysosomes within cells. (author)

  8. Quantitative measurement of membrane Na+-K+ ATPase activity using thallium-201: comparison with rubidium-86

    International Nuclear Information System (INIS)

    Lee, Jae Tae; Shon, Sang Kyun; Lee, Kyu Bo; Lee, In Kyu

    1998-01-01

    Na + -K + ATPase activity has been estimated by the degree of inhibition of cation transport by cardiac glycosides (ouabain) using Rb-86 as a substrate. The biological characteristics of Tl-201 is known to be similar to those of potassium as a transport substrate in the presence of glucose, insulin or phobol myristate acetate (PMA). The purpose of this study was to measure ouabain sensitive Na + -K + ATPase activity using Tl-201 and compare with that using Rb-86. Smooth muscle cells isolated from rat aorta or human placental umbilical artery were cultured, and used to measure cellular Na + -K + ATPase activity. Na + -K + ATPase activity was measured as a percentage decrease in cellular uptake of Tl-201 or Rb-86 by ouabain under the presence of glucose, insulin or PMA in media. Na + -K + ATPase activity measured with Tl-201, as a transport substrate, was not different from those measured with Rb-86 in rat or human smooth muscle cell preparation. Incubation with high concentration glucose resulted in about 30% decrease in enzyme activity. In contrast, insulin or PMA resulted in 50-70% or 28% increase from baseline activity, respectively. These results suggests that Tl-201 could replace Rb-86 in measurement of ouabain sensitive Na + -K + ATPase activity in vitro. High level of glucose concentration decreased cellular Na + -K + ATPase activity, but insulin or PMA increased it

  9. Evaluation of validity and reliability of a methodology for measuring human postural attitude and its relation to temporomandibular joint disorders

    Science.gov (United States)

    Fernández, Ramón Fuentes; Carter, Pablo; Muñoz, Sergio; Silva, Héctor; Venegas, Gonzalo Hernán Oporto; Cantin, Mario; Ottone, Nicolás Ernesto

    2016-01-01

    INTRODUCTION Temporomandibular joint disorders (TMJDs) are caused by several factors such as anatomical, neuromuscular and psychological alterations. A relationship has been established between TMJDs and postural alterations, a type of anatomical alteration. An anterior position of the head requires hyperactivity of the posterior neck region and shoulder muscles to prevent the head from falling forward. This compensatory muscular function may cause fatigue, discomfort and trigger point activation. To our knowledge, a method for assessing human postural attitude in more than one plane has not been reported. Thus, the aim of this study was to design a methodology to measure the external human postural attitude in frontal and sagittal planes, with proper validity and reliability analyses. METHODS The variable postures of 78 subjects (36 men, 42 women; age 18–24 years) were evaluated. The postural attitudes of the subjects were measured in the frontal and sagittal planes, using an acromiopelvimeter, grid panel and Fox plane. RESULTS The method we designed for measuring postural attitudes had adequate reliability and validity, both qualitatively and quantitatively, based on Cohen’s Kappa coefficient (> 0.87) and Pearson’s correlation coefficient (r = 0.824, > 80%). CONCLUSION This method exhibits adequate metrical properties and can therefore be used in further research on the association of human body posture with skeletal types and TMJDs. PMID:26768173

  10. Laser-induced breakdown spectroscopy (LIBS) to measure quantitatively soil carbon with emphasis on soil organic carbon. A review.

    Science.gov (United States)

    Senesi, Giorgio S; Senesi, Nicola

    2016-09-28

    Soil organic carbon (OC) measurement is a crucial factor for quantifying soil C pools and inventories and monitoring the inherent temporal and spatial heterogeneity and changes of soil OC content. These are relevant issues in addressing sustainable management of terrestrial OC aiming to enhance C sequestration in soil, thus mitigating the impact of increasing CO2 concentration in the atmosphere and related effects on global climate change. Nowadays, dry combustion by an elemental analyzer or wet combustion by dichromate oxidation of the soil sample are the most recommended and commonly used methods for quantitative soil OC determination. However, the unanimously recognized uncertainties and limitations of these classical laboursome methods have prompted research efforts focusing on the development and application of more advanced and appealing techniques and methods for the measurement of soil OC in the laboratory and possibly in situ in the field. Among these laser-induced breakdown spectroscopy (LIBS) has raised the highest interest for its unique advantages. After an introduction and a highlight of the LIBS basic principles, instrumentation, methodologies and supporting chemometric methods, the main body of this review provides an historical and critical overview of the developments and results obtained up-to-now by the application of LIBS to the quantitative measurement of soil C and especially OC content. A brief critical summary of LIBS advantages and limitations/drawbacks including some final remarks and future perspectives concludes this review. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. First quantitative measurements by IR spectroscopy of dioxins and furans by means of broadly tunable quantum cascade lasers

    International Nuclear Information System (INIS)

    Siciliani de Cumis, M; D’Amato, F; Viciani, S; Patrizi, B; Foggi, P; Galea, C L

    2013-01-01

    We demonstrate the possibility of a quantitative analysis of the concentration of several dioxins and furans, among the most toxic ones, by only using infrared absorption laser spectroscopy. Two broadly tunable quantum cascade lasers, emitting in the mid-infrared, have been used to measure the absorption spectra of dioxins and furans, dissolved in CCl 4 , in direct absorption mode. The minimum detectable concentrations are inferred by analyzing diluted samples. A comparison between this technique and standard Fourier transform spectroscopy has been carried out and an analysis of future perspectives is reported. (paper)

  12. A development of a quantitative situation awareness measurement tool: Computational Representation of Situation Awareness with Graphical Expressions (CoRSAGE)

    International Nuclear Information System (INIS)

    Yim, Ho Bin; Lee, Seung Min; Seong, Poong Hyun

    2014-01-01

    Highlights: • We proposed quantitative situation awareness (SA) evaluation technique. • We developed a computer based SA evaluation tool for NPPs training environment. • We introduced three rules and components to express more human-like results. • We conducted three sets of training with real plant operators. • Results showed that the tool could reasonably represent operator’s SA. - Abstract: Operator performance measures are used for multiple purposes, such as control room design, human system interface (HSI) evaluation, training, and so on. Performance measures are often focused on results; however, especially for a training purpose – at least in a nuclear industry, more detailed descriptions about processes are required. Situation awareness (SA) measurements have directly/indirectly played as a complimentary measure and provided descriptive insights on how to improve performance of operators for the next training. Unfortunately, most of the well-developed SA measurement techniques, such as Situation Awareness Global Assessment Technique (SAGAT) need an expert opinion which sometimes troubles easy spread of measurement’s application or usage. A quantitative SA measurement tool named Computational Representation of Situation Awareness with Graphical Expressions (CoRSAGE) is introduced to resolve some of these concerns. CoRSAGE is based on production rules to represent a human operator’s cognitive process of problem solving, and Bayesian inference to quantify it. Petri Net concept is also used for graphical expressions of SA flow. Three components – inference transition, volatile/non-volatile memory tokens – were newly developed to achieve required functions. Training data of a Loss of Coolant Accident (LOCA) scenario for an emergency condition and an earthquake scenario for an abnormal condition by real plant operators were used to validate the tool. The validation result showed that CoRSAGE performed a reasonable match to other performance

  13. What is a Beryllium Measurement? A Critical Look at Beryllium Quantitation

    International Nuclear Information System (INIS)

    Charles Davis; Dan Field; John Hess; Dan Jensen

    2006-01-01

    DOE workplaces strive to comply with the 10 CFR 850.31(b)(1) surface concentration release criterion. The usual planning considerations for demonstrating compliance are these: how many swipes, and where; which sample preparation and analytical methods; what reporting limits; and what sample statistic to compare with the criterion. We have reviewed swipe samples from hundreds of Nevada Test Site workplaces: office buildings; experimental facilities; forward area field units; shops; and tunnels. Our experiences have led us to a critical examination of the inner workings of the measurement process itself, involving details generally taken for granted when those usual questions are asked. In this presentation we dissect the ICP-AES Be measurement process. We discuss calibration options and how they impact the distributions of analytical results. We look at distributions of blank results obtained from different labs, and discuss their relevance to determining reporting limits. We examine the way measurements are made from spectra, how that process impacts our understanding of the actual statistical distributions of Be measurements, and how interferences can affect Be measurements. Our objective is to gain sufficient confidence in the measurement process so that the usual questions will make sense and the survey results will be credible. Based on our observations, we offer these recommendations: prepare calibration samples in digested blank swipes; force the calibration line through (0,0); base reporting limits on field blank measurement distributions rather than 40 CFR 236 calculations; use, but do not believe, the usual lognormal distribution assumption; and avoid the 234.861 nm emission line

  14. Software-assisted quantitative analysis of small bowel motility compared to manual measurements

    International Nuclear Information System (INIS)

    Bickelhaupt, S.; Froehlich, J.M.; Cattin, R.; Raible, S.; Bouquet, H.; Bill, U.; Patak, M.A.

    2014-01-01

    Aim: To validate a newly developed software prototype that automatically analyses small bowel motility by comparing it directly with manual measurement. Material and methods: Forty-five patients with clinical indication for small bowel magnetic resonance imaging (MRI) were retrospectively included in this institutional review board-approved study. MRI was performed using a 1.5 T system following a standard MR-enterography protocol. Small bowel motility parameters (contractions-per-minute, luminal diameter, amplitude) were measured three times each in identical segments using the manual and the semiautomatic software-assisted method. The methods were compared for agreement, repeatability, and time needed for each measurement. All parameters were compared between the methods. Results: A total of 91 small-bowel segments were analysed. No significant intra-individual difference (p > 0.05) was found for peristaltic frequencies between the methods (mean: 4.14/min manual; 4.22/min software-assisted). Amplitudes (5.14 mm; 5.57 mm) and mean lumen diameters (17.39 mm; 14.68) differed due to systematic differences in the definition of the bowel wall. Mean duration of single measurement was significantly (p < 0.01) shorter with the software (6.25 min; 1.30 min). The scattering of repeated measurements was significantly (p < 0.05) lower using the software. Conclusion: The software-assisted method accomplished highly reliable, fast and accurate measurement of small bowel motility. Measurement precision and duration differed significantly between the two methods in favour of the software-assisted technique

  15. Quantitative comparisons between experimentally measured 2-D carbon radiation and Monte Carlo impurity (MCI) code simulations

    International Nuclear Information System (INIS)

    Evans, T.E.; Leonard, A.W.; West, W.P.; Finkenthal, D.F.; Fenstermacher, M.E.; Porter, G.D.

    1998-08-01

    Experimentally measured carbon line emissions and total radiated power distributions from the DIII-D divertor and Scrape-Off Layer (SOL) are compared to those calculated with the Monte Carlo Impurity (MCI) model. A UEDGE background plasma is used in MCI with the Roth and Garcia-Rosales (RG-R) chemical sputtering model and/or one of six physical sputtering models. While results from these simulations do not reproduce all of the features seen in the experimentally measured radiation patterns, the total radiated power calculated in MCI is in relatively good agreement with that measured by the DIII-D bolometric system when the Smith78 physical sputtering model is coupled to RG-R chemical sputtering in an unaltered UEDGE plasma. Alternatively, MCI simulations done with UEDGE background ion temperatures along the divertor target plates adjusted to better match those measured in the experiment resulted in three physical sputtering models which when coupled to the RG-R model gave a total radiated power that was within 10% of measured value

  16. Whole-body profile scanner for in vivo quantitative activity measurement

    International Nuclear Information System (INIS)

    Bergmann, H.

    1978-01-01

    A whole-body profile scanner has been developed by fitting parallel slit collimators to a shadow shield whole-body counter. Sensitivity, uniformity and resolution measurements were performed using a number of different counting conditions. It is shown that improved accuracy of activity measurements is obtained by using a wide window counting technique for low and medium energy gamma emitters (99m Tc, 131 I), whereas a photopeak window should be used for high energy gamma emitters (47 Ca). Due to the finite spatial resolution of the system a systematic error in evaluating regional activities from the counting rate profile occurs which is characterized by a spatial spillover factor. The spatial spillover factor is measured and is subsequently used to calculate the error on basis of a simple model. It is shown that only small errors are caused by spatial spillover when the length of a region is at least three times the full width half maximum of the point spread function. Applying the above mentioned simple rules it is concluded that profile scanning is a sensitive and accurate technique for activity measurements in vivo. Two examples of clinical applications (measurement of bone accretion rates of calcium and Tc-pyrophosphate, regional radioiodine retention in patients with thyroid carcinoma) and a review of the papers on profile scanning demonstrate the types of investigations in which profile scanning is superior to alternative techniques. (author)

  17. Quantitative measurement of carbon nanotubes released from their composites using thermal carbon analysis

    International Nuclear Information System (INIS)

    Ogura, I; Honda, K; Shigeta, M; Kotake, M; Uejima, M

    2015-01-01

    The ability of thermal carbon analysis to determine CNTs was evaluated in the presence of a polymer (Polystyrene, PS). Samples placed in an Au (Pt) foil boat were measured using a thermal-carbon analyzer, and the results were compared with gravimetric measurements of sample masses obtained using an ultra-microbalance. First, debris from the polymer without CNTs (i.e., PS debris) was analyzed. The amount of PS debris detected in the organic carbon (OC) fraction was found to be in good agreement with the gravimetrically measured mass of the PS debris, while the amount of pyrolyticallygenerated carbon soot detected in the elemental carbon (EC) fraction was negligible. Next, single-wall CNT (AIST/TASC Super-Growth) powder was analyzed, and the amount of the CNT powder detected in the EC fraction was found to be 95-96% of the gravimetrically measured mass of the CNT powder. Subsequently, a mixture of the PS debris and the CNT powder was analyzed, and the amounts of detected OC and EC were found to be comparable to the gravimetrically measured masses of the PS debris and the CNT powder, respectively. Finally, debris from 5 wt% CNT-PS composites was analyzed, and amounts of OC and EC detected were found to be approximately comparable to the estimated masses of the PS and the CNTs in the debris of CNT-PS composite, respectively. The results therefore indicate thermal carbon analysis is capable of determining CNTs in the presence of PS. (paper)

  18. Quantitative susceptibility mapping (QSM) as a means to measure brain iron? A post mortem validation study

    Science.gov (United States)

    Langkammer, Christian; Schweser, Ferdinand; Krebs, Nikolaus; Deistung, Andreas; Goessler, Walter; Scheurer, Eva; Sommer, Karsten; Reishofer, Gernot; Yen, Kathrin; Fazekas, Franz; Ropele, Stefan; Reichenbach, Jürgen R.

    2012-01-01

    Quantitative susceptibility mapping (QSM) is a novel technique which allows determining the bulk magnetic susceptibility distribution of tissue in vivo from gradient echo magnetic resonance phase images. It is commonly assumed that paramagnetic iron is the predominant source of susceptibility variations in gray matter as many studies have reported a reasonable correlation of magnetic susceptibility with brain iron concentrations in vivo. Instead of performing direct comparisons, however, all these studies used the putative iron concentrations reported in the hallmark study by Hallgren and Sourander (1958) for their analysis. Consequently, the extent to which QSM can serve to reliably assess brain iron levels is not yet fully clear. To provide such information we investigated the relation between bulk tissue magnetic susceptibility and brain iron concentration in unfixed (in situ) post mortem brains of 13 subjects using MRI and inductively coupled plasma mass spectrometry. A strong linear correlation between chemically determined iron concentration and bulk magnetic susceptibility was found in gray matter structures (r = 0.84, p < 0.001), whereas the correlation coefficient was much lower in white matter (r = 0.27, p < 0.001). The slope of the overall linear correlation was consistent with theoretical considerations of the magnetism of ferritin supporting that most of the iron in the brain is bound to ferritin proteins. In conclusion, iron is the dominant source of magnetic susceptibility in deep gray matter and can be assessed with QSM. In white matter regions the estimation of iron concentrations by QSM is less accurate and more complex because the counteracting contribution from diamagnetic myelinated neuronal fibers confounds the interpretation. PMID:22634862

  19. Dominance in Domestic Dogs: A Quantitative Analysis of Its Behavioural Measures.

    Science.gov (United States)

    van der Borg, Joanne A M; Schilder, Matthijs B H; Vinke, Claudia M; de Vries, Han

    2015-01-01

    A dominance hierarchy is an important feature of the social organisation of group living animals. Although formal and/or agonistic dominance has been found in captive wolves and free-ranging dogs, applicability of the dominance concept in domestic dogs is highly debated, and quantitative data are scarce. Therefore, we investigated 7 body postures and 24 behaviours in a group of domestic dogs for their suitability as formal status indicators. The results showed that high posture, displayed in most dyadic relationships, and muzzle bite, displayed exclusively by the highest ranking dogs, qualified best as formal dominance indicators. The best formal submission indicator was body tail wag, covering most relationships, and two low postures, covering two-thirds of the relationships. In addition, both mouth lick, as included in Schenkel's active submission, and pass under head qualified as formal submission indicators but were shown almost exclusively towards the highest ranking dogs. Furthermore, a status assessment based on changes in posture displays, i.e., lowering of posture (LoP) into half-low, low, low-on-back or on-back, was the best status indicator for most relationships as it showed good coverage (91% of the dyads), a nearly linear hierarchy (h' = 0.94, pdog group. No significant correlations of rank with age or weight were found. Strong co-variation between LoP, high posture, and body tail wag justified the use of dominance as an intervening variable. Our results are in line with previous findings for captive wolves and free-ranging dogs, for formal dominance with strong linearity based on submission but not aggression. They indicate that the ethogram for dogs is best redefined by distinguishing body postures from behavioural activities. A good insight into dominance hierarchies and its indicators will be helpful in properly interpreting dog-dog relationships and diagnosing problem behaviour in dogs.

  20. A quantitative model for estimating mean annual soil loss in cultivated land using 137Cs measurements

    International Nuclear Information System (INIS)

    Yang Hao; Zhao Qiguo; Du Mingyuan; Minami, Katsuyuki; Hatta, Tamao

    2000-01-01

    The radioisotope 137 Cs has been widely used to determine rates of cultivated soil loss, Many calibration relationships (including both empirical relationships and theoretical models) have been employed to estimate erosion rates from the amount of 137 Cs lost from the cultivated soil profile. However, there are important limitations which restrict the reliability of these models, which consider only the uniform distribution of 137 Cs in the plough layer and the depth. As a result, erosion rates they may be overestimated or underestimated. This article presents a quantitative model for the relation the amount of 137 Cs lost from the cultivate soil profile and the rate of soil erosion. According to a mass balance model, during the construction of this model we considered the following parameters: the remaining fraction of the surface enrichment layer (F R ), the thickness of the surface enrichment layer (H s ), the depth of the plough layer (H p ), input fraction of the total 137 Cs fallout deposition during a given year t (F t ), radioactive decay of 137 Cs (k), and sampling year (t). The simulation results showed that the amounts of erosion rates estimated using this model were very sensitive to changes in the values of the parameters F R , H s , and H p . We also observed that the relationship between the rate of soil loss and 137 Cs depletion is neither linear nor logarithmic, and is very complex. Although the model is an improvement over existing approaches to derive calibration relationships for cultivated soil, it requires empirical information on local soil properties and the behavior of 137 Cs in the soil profile. There is clearly still a need for more precise information on the latter aspect and, in particular, on the retention of 137 Cs fallout in the top few millimeters of the soil profile and on the enrichment and depletion effects associated with soil redistribution (i.e. for determining accurate values of F R and H s ). (author)

  1. Predicting acute side effects of stimulant medication in pediatric attention deficit/hyperactivity disorder: data from quantitative electroencephalography, event-related potentials, and a continuous-performance test

    Directory of Open Access Journals (Sweden)

    Ogrim G

    2013-09-01

    Full Text Available Geir Ogrim,1–3 Knut A Hestad,3,4 Jan Ferenc Brunner,3,5,6 Juri Kropotov3,7,8 1Neuropsychiatric Unit, Østfold Hospital Trust, Fredrikstad, Norway; 2National Resource Center for ADHD, Tourettes' Syndrome and Narcolepsy, Oslo, Norway; 3Institute of Psychology, Norwegian University of Science and Technology (NTNU, Trondheim, Norway; 4Division of Mental Health, Innlandet Hospital Trust, Brumunddal, Norway; 5Department of Physical Medicine and Rehabilitation, St Olav's Hospital, Trondheim, Norway; 6Department of Neuroscience, NTNU, Trondheim, Norway; 7Institute of the Human Brain, Russian Academy of Sciences, Saint Petersburg, Russia; 8Department of Neuropsychology, Andrzej Frycz Modrzewski Krakow University, Krakow, Poland Background: The aim of this study was to search for predictors of acute side effects of stimulant medication in pediatric attention deficit/hyperactivity disorder (ADHD, emphasizing variables from quantitative electroencephalography (QEEG, event-related potentials (ERPs, and behavior data from a visual continuous-performance test (VCPT. Methods: Seventy medication-naïve ADHD patients aged 7–16 years were tested with QEEG, including a go/no-go task condition (VCPT from which behavior data and ERPs were extracted, followed by a systematic trial on stimulant medication lasting at least 4 weeks. Based on data from rating scales and interviews, two psychologists who were blind to the QEEG/ERP test results independently rated the patients as having no or small side effects (n = 37 or troublesome side effects (n = 33. We determined if the side effects were related to sex, age, IQ, ADHD subtype, comorbidities, clinical outcome, and variables in QEEG, ERPs, and VCPT. Results: There was a moderate negative correlation between clinical outcome and side effects. Three variables were significantly associated with side effects in a multivariate logistic regression analysis. In the ERP independent component – contingent negative variation

  2. System for quantitative measurements of methane emission from dairy cattle in Denmark

    DEFF Research Database (Denmark)

    Hellwing, Anne Louise Frydendahl; Lund, Peter; Johannes, Maike

    the chamber air. The system constitutes of four chambers, flow meters and gas sensors for measuring methane, oxygen and carbon dioxide. The outside measurements of chambers are approximately 1.45 * 3.9 * 2.45 meters. Inside there is a platform to give the cows a comfortable laying area, space for feeding bin......, water bowl and draining of urine and faeces. The air flow out of the chambers can be controlled individually by a motor controller. The outlet is in the top of the chambers through a filter box to reduce the dust content before the flow meter (Teledyne Hastings, delivered by Columbus instruments, Ohio......, USA), which can measure flow rates up to 3000 standard liters per minute. After the air has passed the flow meter an air sample is drawn. A manifold, drying system, oxygen sensor, carbon dioxide sensor, methane sensor, and data program for management were delivered by Columbus instruments (Ohio, USA...

  3. Quantitative estimation of defects from measurement obtained by remote field eddy current inspection

    International Nuclear Information System (INIS)

    Davoust, M.E.; Fleury, G.

    1999-01-01

    Remote field eddy current technique is used for dimensioning grooves that may occurs in ferromagnetic pipes. This paper proposes a method to estimate the depth and the length of corrosion grooves from measurement of a pick-up coil signal phase at different positions close to the defect. Grooves dimensioning needs the knowledge of the physical relation between measurements and defect dimensions. So, finite element calculations are performed to obtain a parametric algebraic function of the physical phenomena. By means of this model and a previously defined general approach, an estimate of groove size may be given. In this approach, algebraic function parameters and groove dimensions are linked through a polynomial function. In order to validate this estimation procedure, a statistical study has been performed. The approach is proved to be suitable for real measurements. (authors)

  4. Reliability and short-term intra-individual variability of telomere length measurement using monochrome multiplexing quantitative PCR.

    Directory of Open Access Journals (Sweden)

    Sangmi Kim

    Full Text Available Studies examining the association between telomere length and cancer risk have often relied on measurement of telomere length from a single blood draw using a real-time PCR technique. We examined the reliability of telomere length measurement using sequential samples collected over a 9-month period.Relative telomere length in peripheral blood was estimated using a single tube monochrome multiplex quantitative PCR assay in blood DNA samples from 27 non-pregnant adult women (aged 35 to 74 years collected in 7 visits over a 9-month period. A linear mixed model was used to estimate the components of variance for telomere length measurements attributed to variation among women and variation between time points within women. Mean telomere length measurement at any single visit was not significantly different from the average of 7 visits. Plates had a significant systematic influence on telomere length measurements, although measurements between different plates were highly correlated. After controlling for plate effects, 64% of the remaining variance was estimated to be accounted for by variance due to subject. Variance explained by time of visit within a subject was minor, contributing 5% of the remaining variance.Our data demonstrate good short-term reliability of telomere length measurement using blood from a single draw. However, the existence of technical variability, particularly plate effects, reinforces the need for technical replicates and balancing of case and control samples across plates.

  5. A Critical Evaluation of Quantitative Measures of the Quality of Arts and Culture

    DEFF Research Database (Denmark)

    Bille, Trine

    Art and culture i.e. theatre, film, music, visual art, literature, cultural heritage etc. and related institutions and participants, have traditionally not been measured and evaluated in the same way as other sectors. The reason for this is perhaps that art and culture cannot be ‘weighed and meas......Art and culture i.e. theatre, film, music, visual art, literature, cultural heritage etc. and related institutions and participants, have traditionally not been measured and evaluated in the same way as other sectors. The reason for this is perhaps that art and culture cannot be ‘weighed...

  6. Combination of optically measured coordinates and displacements for quantitative investigation of complex objects

    Science.gov (United States)

    Andrae, Peter; Beeck, Manfred-Andreas; Jueptner, Werner P. O.; Nadeborn, Werner; Osten, Wolfgang

    1996-09-01

    Holographic interferometry makes it possible to measure high precision displacement data in the range of the wavelength of the used laser light. However, the determination of 3D- displacement vectors of objects with complex surfaces requires the measurement of 3D-object coordinates not only to consider local sensitivities but to distinguish between in-plane deformation, i.e. strains, and out-of-plane components, i.e. shears, too. To this purpose both the surface displacement and coordinates have to be combined and it is advantageous to make the data available for CAE- systems. The object surface has to be approximated analytically from the measured point cloud to generate a surface mesh. The displacement vectors can be assigned to the nodes of this surface mesh for visualization of the deformation of the object under test. They also can be compared to the results of FEM-calculations or can be used as boundary conditions for further numerical investigations. Here the 3D-object coordinates are measured in a separate topometric set-up using a modified fringe projection technique to acquire absolute phase values and a sophisticated geometrical model to map these phase data onto coordinates precisely. The determination of 3D-displacement vectors requires the measurement of several interference phase distributions for at least three independent sensitivity directions depending on the observation and illumination directions as well as the 3D-position of each measuring point. These geometric quantities have to be transformed into a reference coordinate system of the interferometric set-up in order to calculate the geometric matrix. The necessary transformation can be realized by means of a detection of object features in both data sets and a subsequent determination of the external camera orientation. This paper presents a consistent solution for the measurement and combination of shape and displacement data including their transformation into simulation systems. The

  7. Performance management in universities : Effects of the transition to more quantitative measurement systems

    NARCIS (Netherlands)

    ter Bogt, H.J.; Scapens, R.W.

    2012-01-01

    The measurement of research and teaching performance is increasingly common within universities, driven probably by the rise of New Public Management (NPM). Although changing over time and varying from country to country, NPM involves the use of private sector methods in the public sector.

  8. Towards quantitative measurements of relaxation times and other parameters in the brain

    International Nuclear Information System (INIS)

    Tofts, P.S.; Du Boulay, E.P.G.H.

    1990-01-01

    The nature and physical significance of the relaxation times T1 and T2 and of proton density are described. Methods of measuring T1 and T2 are discussed with emphasis on the establishment of precision and the maintenance of accuracy. Reported standards of success are briefly reviewed. We expect sensitivities of the order of 1% to be achievable in serial studies. Although early hopes of disease diagnosis by tissue characterisation were not realised, strict scientific method and careful calibration have made it pracitcable to apply relaxation time measurement to research into disease process. Serial measurements in patients and correlation with similar studies in animal models, biopsy results and autopsy material taken together have provided new knowledge about cerebral oedema, water compartmentation, alcoholism and the natural history of multiple sclerosis. There are prospects of using measurement to monitor treatment in other diseases with diffuse brain abnormalities invisible on the usual images. Secondarily derived parameters and notably the quantification of blood-brain barrier defect after injection of Gadolinium-DTPA also offer prospects of valuable data. (orig.)

  9. Comparative evaluation of quantitative glomerular filtration rate measured by isotopic and nonisotopic methods

    International Nuclear Information System (INIS)

    Balachandran, S.; Toguri, A.G.; Petrusick, T.W.; Abbott, L.C.

    1981-01-01

    Good correlation of glomerular filtration rate (GFR) measured isotopically from plasma disappearance of Tc-99m-DTPA (Sn) was shown with inulin clearance, creatinine clearance, and graded radionuclide imaging. The isotopic GFR is a simple, urineless technique not requiring continuous infusion that enables one to perform simultaneous renal imaging with one radiotracer

  10. The reproducibility of quantitative measurements in lumbar magnetic resonance imaging of children from the general population

    DEFF Research Database (Denmark)

    Masharawi, Y; Kjær, Per; Bendix, T

    2008-01-01

    --zygoappophyseal tranverse superior facet angles, sagittal VB, and disc wedging, lumbar lordosis, and sacral inclination. Statistical analysis included the concordance correlation coefficient (CCC), and Bland and Altman's limits of agreement (LOA). RESULTS: A total of 6160 measurements were analyzed. Good to excellent...... intratester reproducibility (0.75 lordosis, and sacral inclination (LOA: 11.22 degrees ; 12.34 degrees). VB and disc...

  11. Measurement of vertebral bone density. Quantitative CT or dual-photon absorptiometry

    International Nuclear Information System (INIS)

    Bergot, C.; Laval-Jeantet, A.M.; Laval-Jeantet, M.H.; Kuntz, D.

    1993-01-01

    We have compared vertebral bone density measurements (QCT and DXA) in women in the postmenopausal period who underwent both examinations. Our aim was to study the results and to define the respective indications of QCT and DXA in various clinical pictures of osteoporosis. The subjects of the study were distributed into various groups according to the presence or absence of vertebral collapse and/or peripheral fractures. The results of the measurements were expressed as Z-scores (deviation from age-normal average) to suppress the age effect and to make comparison between both methods possible. The values of both measurements are significantly lower in case of vertebral involvement. QCT is more sensitive than DXA to discriminate vertebral collapse. A vertebral fragility threshold was defined at a Z-score of-1 with DXA and-1.25 with QCT, corresponding to the best sensitivity for an acceptable specificity. The results of densitometry suggest that there is a peripheral osteoporosis, different from vertebral osteoporosis, as early as the postmenopausal period. Since DXA is easy to implement, it can be used to screen osteoporosis. When the vertebral measurement with DXA is normal although osteoporosis is obvious (previous collapse or fracture), QCT must be used as it is more sensitive

  12. A quantitative approach to measuring the cerebrospinal fluid space with CT

    International Nuclear Information System (INIS)

    Zeumer, H.; Hacke, W.; Hartwich, P.

    1982-01-01

    A method for measuring the subarachnoid space by using an independent CT evaluation unit is described. The normal values have been calculated for patients, according to age, and three examples are presented demonstrating reversible decrease of brain volume in patients suffering anorexia nervosa and chronic alcoholism. (orig.)

  13. Identification of Phosphoglycerate Kinase 1 (PGK1 as a reference gene for quantitative gene expression measurements in human blood RNA

    Directory of Open Access Journals (Sweden)

    Unger Elizabeth R

    2011-09-01

    Full Text Available Abstract Background Blood is a convenient sample and increasingly used for quantitative gene expression measurements with a variety of diseases including chronic fatigue syndrome (CFS. Quantitative gene expression measurements require normalization of target genes to reference genes that are stable and independent from variables being tested in the experiment. Because there are no genes that are useful for all situations, reference gene selection is an essential step to any quantitative reverse transcription-PCR protocol. Many publications have described appropriate genes for a wide variety of tissues and experimental conditions, however, reference genes that may be suitable for the analysis of CFS, or human blood RNA derived from whole blood as well as isolated peripheral blood mononuclear cells (PBMCs, have not been described. Findings Literature review and analyses of our unpublished microarray data were used to narrow down the pool of candidate reference genes to six. We assayed whole blood RNA from Tempus tubes and cell preparation tube (CPT-collected PBMC RNA from 46 subjects, and used the geNorm and NormFinder algorithms to select the most stable reference genes. Phosphoglycerate kinase 1 (PGK1 was one of the optimal normalization genes for both whole blood and PBMC RNA, however, additional genes differed for the two sample types; Ribosomal protein large, P0 (RPLP0 for PBMC RNA and Peptidylprolyl isomerase B (PPIB for whole blood RNA. We also show that the use of a single reference gene is sufficient for normalization when the most stable candidates are used. Conclusions We have identified PGK1 as a stable reference gene for use with whole blood RNA and RNA derived from PBMC. When stable genes are selected it is possible to use a single gene for normalization rather than two or three. Optimal normalization will improve the ability of results from PBMC RNA to be compared with those from whole blood RNA and potentially allows comparison of

  14. A bench-top K X-ray fluorescence system for quantitative measurement of gold nanoparticles for biological sample diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Ricketts, K., E-mail: k.ricketts@ucl.ac.uk [Division of Surgery and Interventional Sciences, University College London, Royal Free Campus, Rowland Hill Street, London NW3 2PF (United Kingdom); Guazzoni, C.; Castoldi, A. [Dipartimento di Elettronica, Informazione e Bioingegneria Politecnico di Milano and INFN, Sezione di Milano P.za Leonardo da Vinci, 32-20133 Milano (Italy); Royle, G. [Department of Medical Physics and Bioengineering, University College London, Malet Place Engineering Building, Gower Street, London WC1E 6BT (United Kingdom)

    2016-04-21

    Gold nanoparticles can be targeted to biomarkers to give functional information on a range of tumour characteristics. X-ray fluorescence (XRF) techniques offer potential quantitative measurement of the distribution of such heavy metal nanoparticles. Biologists are developing 3D tissue engineered cellular models on the centimetre scale to optimise targeting techniques of nanoparticles to a range of tumour characteristics. Here we present a high energy bench-top K-X-ray fluorescence system designed for sensitivity to bulk measurement of gold nanoparticle concentration for intended use in such thick biological samples. Previous work has demonstrated use of a L-XRF system in measuring gold concentrations but being a low energy technique it is restricted to thin samples or superficial tumours. The presented system comprised a high purity germanium detector and filtered tungsten X-ray source, capable of quantitative measurement of gold nanoparticle concentration of thicker samples. The developed system achieved a measured detection limit of between 0.2 and 0.6 mgAu/ml, meeting specifications of biologists and being approximately one order of magnitude better than the detection limit of alternative K-XRF nanoparticle detection techniques. The scatter-corrected K-XRF signal of gold was linear with GNP concentrations down to the detection limit, thus demonstrating potential in GNP concentration quantification. The K-XRF system demonstrated between 5 and 9 times less sensitivity than a previous L-XRF bench-top system, due to a fundamental limitation of lower photoelectric interaction probabilities at higher K-edge energies. Importantly, the K-XRF technique is however less affected by overlying thickness, and so offers future potential in interrogating thick biological samples.

  15. Facial Phenotyping by Quantitative Photography Reflects Craniofacial Morphology Measured on Magnetic Resonance Imaging in Icelandic Sleep Apnea Patients

    Science.gov (United States)

    Sutherland, Kate; Schwab, Richard J.; Maislin, Greg; Lee, Richard W.W.; Benedikstdsottir, Bryndis; Pack, Allan I.; Gislason, Thorarinn; Juliusson, Sigurdur; Cistulli, Peter A.

    2014-01-01

    Study Objectives: (1) To determine whether facial phenotype, measured by quantitative photography, relates to underlying craniofacial obstructive sleep apnea (OSA) risk factors, measured with magnetic resonance imaging (MRI); (2) To assess whether these associations are independent of body size and obesity. Design: Cross-sectional cohort. Setting: Landspitali, The National University Hospital, Iceland. Participants: One hundred forty patients (87.1% male) from the Icelandic Sleep Apnea Cohort who had both calibrated frontal and profile craniofacial photographs and upper airway MRI. Mean ± standard deviation age 56.1 ± 10.4 y, body mass index 33.5 ± 5.05 kg/m2, with on-average severe OSA (apnea-hypopnea index 45.4 ± 19.7 h-1). Interventions: N/A. Measurements and Results: Relationships between surface facial dimensions (photos) and facial bony dimensions and upper airway soft-tissue volumes (MRI) was assessed using canonical correlation analysis. Photo and MRI craniofacial datasets related in four significant canonical correlations, primarily driven by measurements of (1) maxillary-mandibular relationship (r = 0.8, P photography and MRI. This study confirms that facial photographic phenotype reflects underlying aspects of craniofacial skeletal abnormalities associated with OSA. Therefore, facial photographic phenotyping may be a useful tool to assess intermediate phenotypes for OSA, particularly in large-scale studies. Citation: Sutherland K, Schwab RJ, Maislin G, Lee RW, Benedikstdsottir B, Pack AI, Gislason T, Juliusson S, Cistulli PA. Facial phenotyping by quantitative photography reflects craniofacial morphology measured on magnetic resonance imaging in icelandic sleep apnea patients. SLEEP 2014;37(5):959-968. PMID:24790275

  16. Quantitation of 24-Hour Moisturization by Electrical Measurements of Skin Hydration.

    Science.gov (United States)

    Wickett, R Randall; Damjanovic, Bronson

    The purpose of this study was to quantify the effects of several moisturizers on hydration of the stratum corneum by measuring their effect on electrical conductance over a 24-hour period. Double-blind, randomized controlled trial. Twenty-five healthy female volunteers aged 18 to 65 years with dry skin on the lower legs and no other known dermatologic pathology participated in the study. Additional exclusion criteria were pregnant or taking anti-inflammatory steroids. The study was carried out in a clinical research facility in Winnipeg, Manitoba, Canada. Subjects underwent a 3-day conditioning period using a natural soap bar on the lower legs and no application of moisturizer to the skin. Participants then came to the test site and equilibrated for at least 30 minutes under controlled conditions of temperature and humidity. After baseline hydration measurements on test sites on the lower legs of each subject, a single application of each of 5 test products at a dose of 2 mg/cm was made. Skin hydration was assessed by electrical conductance measurements with a specialized probe. The probe was briefly placed on the skin surface with light pressure, and the measurement recorded in units of microsiemens (μS). Conductance was measured at 2, 4, 6, 8, and 24 hours after product applications. Although all but 1 of the test products increased conductance at 2 hours, only 2 moisturizers containing high levels of glycerin (products C and E) maintained increased conductance relative to baseline at 24 hours, +37.8 (P skin conductance for at least 24 hours after a single application.

  17. Proton-density fat fraction measurement: A viable quantitative biomarker for differentiating adrenal adenomas from nonadenomas

    Energy Technology Data Exchange (ETDEWEB)

    Meng, Xiaoyan; Chen, Xiao; Shen, Yaqi; Hu, Xuemei; Tang, Hao; Hu, Daoyu [Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei (China); Li, Zhen, E-mail: zhenli@hust.edu.cn [Department of Radiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei (China); Kamel, Ihab R. [Russell H. Morgan Department of Radiology and Radiological Science, the Johns Hopkins Medical Institutions, Baltimore, Maryland (United States)

    2017-01-15

    Highlights: • PDFF differentiated adenomas from nonadenomas with high sensitivity and specificity. • PDFF measurements are simple and can be readily applicable in clinical practice. • Oil-saline phantom study demonstarted good correlation between PDFF and SII. - Abstract: Purpose: This study aims to compare the accuracy of proton-density fat fraction (PDFF) measurements with chemical shift magnetic resonance imaging (CSI) for quantifying the fat content of adrenal nodules and for differentiating adenomas from nonadenomas. Materials and methods: Oil-saline phantom measurements was performed to compare the correlation between PDFF and CSI in detecting and quantifying fat content. 43 consecutive patients who had known adrenal nodules were imaged on a 3.0-T MR scanner. PDFF was measured, and the signal intensity (SI) index (SII), SI adrenal-to-liver ratio (ALR) and SI adrenal-to-spleen ratio (ASR) of the adrenal nodules were calculated. Results: In the phantom study, PDFF ranged from 12.6% to 99.1% and the SII was between 0.72 and 1.23. There was good correlation between these two methods (R square = 0.972, p < 0.0001). The PDFF of adrenal adenoma was significantly increased compared with that of nonadenoma (p < 0.001). PDFF was an effective tool for distinguishing adenoma from nonadenoma, with an area under the curve (AUC) of 0.98. In comparing SII, ALR and ASR the AUC was 0.94, 0.95 and 0.93, respectively. No significant difference was noted between these two methods (p > 0.05). Conclusion: PDFF measurements provide an accurate estimation of fat content in discriminating adenomas from nonadenomas compared with CSI, avoiding complicated data calculations and offering a simpler technique using 3T.

  18. Measurement issues associated with quantitative molecular biology analysis of complex food matrices for the detection of food fraud.

    Science.gov (United States)

    Burns, Malcolm; Wiseman, Gordon; Knight, Angus; Bramley, Peter; Foster, Lucy; Rollinson, Sophie; Damant, Andrew; Primrose, Sandy

    2016-01-07

    Following a report on a significant amount of horse DNA being detected in a beef burger product on sale to the public at a UK supermarket in early 2013, the Elliott report was published in 2014 and contained a list of recommendations for helping ensure food integrity. One of the recommendations included improving laboratory testing capacity and capability to ensure a harmonised approach for testing for food authenticity. Molecular biologists have developed exquisitely sensitive methods based on the polymerase chain reaction (PCR) or mass spectrometry for detecting the presence of particular nucleic acid or peptide/protein sequences. These methods have been shown to be specific and sensitive in terms of lower limits of applicability, but they are largely qualitative in nature. Historically, the conversion of these qualitative techniques into reliable quantitative methods has been beset with problems even when used on relatively simple sample matrices. When the methods are applied to complex sample matrices, as found in many foods, the problems are magnified resulting in a high measurement uncertainty associated with the result which may mean that the assay is not fit for purpose. However, recent advances in the technology and the understanding of molecular biology approaches have further given rise to the re-assessment of these methods for their quantitative potential. This review focuses on important issues for consideration when validating a molecular biology assay and the various factors that can impact on the measurement uncertainty of a result associated with molecular biology approaches used in detection of food fraud, with a particular focus on quantitative PCR-based and proteomics assays.

  19. Dominance in Domestic Dogs: A Quantitative Analysis of Its Behavioural Measures.

    Directory of Open Access Journals (Sweden)

    Joanne A M van der Borg

    Full Text Available A dominance hierarchy is an important feature of the social organisation of group living animals. Although formal and/or agonistic dominance has been found in captive wolves and free-ranging dogs, applicability of the dominance concept in domestic dogs is highly debated, and quantitative data are scarce. Therefore, we investigated 7 body postures and 24 behaviours in a group of domestic dogs for their suitability as formal status indicators. The results showed that high posture, displayed in most dyadic relationships, and muzzle bite, displayed exclusively by the highest ranking dogs, qualified best as formal dominance indicators. The best formal submission indicator was body tail wag, covering most relationships, and two low postures, covering two-thirds of the relationships. In addition, both mouth lick, as included in Schenkel's active submission, and pass under head qualified as formal submission indicators but were shown almost exclusively towards the highest ranking dogs. Furthermore, a status assessment based on changes in posture displays, i.e., lowering of posture (LoP into half-low, low, low-on-back or on-back, was the best status indicator for most relationships as it showed good coverage (91% of the dyads, a nearly linear hierarchy (h' = 0.94, p<0.003 and strong unidirectionality (DCI = 0.97. The associated steepness of 0.79 (p<0.0001 indicated a tolerant dominance style for this dog group. No significant correlations of rank with age or weight were found. Strong co-variation between LoP, high posture, and body tail wag justified the use of dominance as an intervening variable. Our results are in line with previous findings for captive wolves and free-ranging dogs, for formal dominance with strong linearity based on submission but not aggression. They indicate that the ethogram for dogs is best redefined by distinguishing body postures from behavioural activities. A good insight into dominance hierarchies and its indicators will be

  20. Application and measurement properties of EQ-5D to measure quality of life in patients with upper extremity orthopaedic disorders: a systematic literature review.

    Science.gov (United States)

    Grobet, Cécile; Marks, Miriam; Tecklenburg, Linda; Audigé, Laurent

    2018-04-13

    The EuroQol-5 Dimension (EQ-5D) is the most widely used generic instrument to measure quality of life (QoL), yet its application in upper extremity orthopaedics as well as its measurement properties remain largely undefined. We implemented a systematic literature review to provide an overview of the application of EQ-5D in patients with upper extremity disorders and analyse its measurement properties. We searched Medline, EMBASE, Cochrane and Scopus databases for clinical studies including orthopaedic patients with surgical interventions of the upper extremity who completed the EQ-5D. For all included studies, the use of EQ-5D and quantitative QoL data were described. Validation studies of EQ-5D were assessed according to COSMIN guidelines and standard measurement properties were examined. Twenty-three studies were included in the review, 19 of which investigated patients with an intervention carried out at the shoulder region. In 15 studies, EQ-5D assessed QoL as the primary outcome. Utility index scores in non-trauma patients generally improved postoperatively, whereas trauma patients did not regain their recalled pre-injury QoL levels. EQ-5D measurement properties were reported in three articles on proximal humerus fractures and carpal tunnel syndrome. Positive ratings were seen for construct validity (Spearman correlation coefficient ≥ 0.70 with the Short Form (SF)-12 or SF-6D health surveys) and reliability (intraclass correlation coefficient ≥ 0.77) with intermediate responsiveness (standardised response means: 0.5-0.9). However, ceiling effects were identified with 16-48% of the patients scoring the maximum QoL. The methodological quality of the three articles varied from fair to good. For surgical interventions of the upper extremity, EQ-5D was mostly applied to assess QoL as a primary outcome in patients with shoulder disorders. Investigations of the measurement properties were rare, but indicate good reliability and validity as well as

  1. Quantitative computed tomography measurements to evaluate airway disease in chronic obstructive pulmonary disease: Relationship to physiological measurements, clinical index and visual assessment of airway disease

    Energy Technology Data Exchange (ETDEWEB)

    Nambu, Atsushi, E-mail: nambu-a@gray.plala.or.jp [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO, 80206 (United States); Zach, Jordan, E-mail: ZachJ@NJHealth.org [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO, 80206 (United States); Schroeder, Joyce, E-mail: Joyce.schroeder@stanfordalumni.org [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO, 80206 (United States); Jin, Gongyoung, E-mail: gyjin@chonbuk.ac.kr [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO, 80206 (United States); Kim, Song Soo, E-mail: haneul88@hanmail.net [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO, 80206 (United States); Kim, Yu-IL, E-mail: kyionly@chonnam.ac.kr [Department of Medicine, National Jewish Health, Denver, CO (United States); Schnell, Christina, E-mail: SchnellC@NJHealth.org [Department of Medicine, National Jewish Health, Denver, CO (United States); Bowler, Russell, E-mail: BowlerR@NJHealth.org [Division of Pulmonary Medicine, Department of Medicine, National Jewish Health (United States); Lynch, David A., E-mail: LynchD@NJHealth.org [Department of Radiology, National Jewish Health, 1400 Jackson Street, Denver, CO, 80206 (United States)

    2016-11-15

    Purpose: To correlate currently available quantitative CT measurements for airway disease with physiological indices and the body-mass index, airflow obstruction, dyspnea, and exercise capacity (BODE) index in patients with chronic obstructive pulmonary disease (COPD). Materials and methods: This study was approved by our institutional review board (IRB number 2778). Written informed consent was obtained from all subjects. The subjects included 188 current and former cigarette smokers from the COPDGene cohort who underwent inspiratory and expiratory CT and also had physiological measurements for the evaluation of airflow limitation, including FEF25-75%, airway resistance (Raw), and specific airway conductance (sGaw). The BODE index was used as the index of clinical symptoms. Quantitative CT measures included % low attenuation areas [% voxels ≤ 950 Hounsfield unit (HU) on inspiratory CT, %LAA{sub −950ins}], percent gas trapping (% voxels ≤ −856 HU on expiratory CT, %LAA {sub −856exp}), relative inspiratory to expiratory volume change of voxels with attenuation values from −856 to −950 HU [Relative Volume Change (RVC){sub −856} {sub to} {sub −950}], expiratory to inspiratory ratio of mean lung density (E/I-ratio {sub MLD}), Pi10, and airway wall thickness (WT), luminal diameter (LD) and airway wall area percent (WA%) in the segmental, subsegmental and subsubsegmental bronchi on inspiratory CT. Correlation coefficients were calculated between the QCT measurements and physiological measurements in all subjects and in the subjects with mild emphysema (%LAA{sub −950ins} <10%). Univariate and multiple variable analysis for the BODE index were also performed. Adjustments were made for age, gender, smoking pack years, FEF25-75%, Raw, and sGaw. Results: Quantitative CT measurements had significant correlations with physiological indices. Among them, E/I-ratio {sub MLD} had the strongest correlations with FEF25-75% (r = −0.648, <0.001) and sGaw (r = −0

  2. Non-pharmacological interventions for attention-deficit/hyperactivity disorder (ADHD) delivered in school settings: systematic reviews of quantitative and qualitative research.

    Science.gov (United States)

    Richardson, Michelle; Moore, Darren A; Gwernan-Jones, Ruth; Thompson-Coon, Jo; Ukoumunne, Obioha; Rogers, Morwenna; Whear, Rebecca; Newlove-Delgado, Tamsin V; Logan, Stuart; Morris, Christopher; Taylor, Eric; Cooper, Paul; Stein, Ken; Garside, Ruth; Ford, Tamsin J

    2015-01-01

    BACKGROUND Attention-deficit/hyperactivity disorder (ADHD) is a neurodevelopmental disorder characterised by age-inappropriate levels of inattention, impulsivity and hyperactivity. School can be particularly challenging for children with ADHD. Few reviews have considered non-pharmacological interventions in school settings. OBJECTIVES To assess the effectiveness of non-pharmacological interventions delivered in school settings for pupils with, or at risk of, ADHD and to explore the factors that may enhance, or limit, their delivery. DATA SOURCES Twenty electronic databases (including PsycINFO, MEDLINE, EMBASE, Education Resources Information Centre, The Cochrane Library and Education Research Complete) were searched from 1980 to February-August 2013. Three separate searches were conducted for four systematic reviews; they were supplemented with forward and backwards citation chasing, website searching, author recommendations and hand-searches of key journals. REVIEW METHODS The systematic reviews focused on (1) the effectiveness of school-based interventions for children with or at risk of ADHD; (2) quantitative research that explores attitudes towards school-based non-pharmacological interventions for pupils with ADHD; (3) qualitative research investigating the attitudes and experiences of children, teachers, parents and others using ADHD interventions in school settings; and (4) qualitative research exploring the experience of ADHD in school among pupils, their parents and teachers more generally. Methods of synthesis included a random-effects meta-analysis, meta-regression and narrative synthesis for review 1, narrative synthesis for review 2 and meta-ethnography and thematic analysis for reviews 3 and 4. RESULTS For review 1, 54 controlled trials met the inclusion criteria. For the 36 meta-analysed randomised controlled trials, beneficial effects (p views about the impact of interventions, although it was clear that interventions both influence and are

  3. /sup 99m/Tc-labeled solid-phase meal: a quantitative clinical measurement of human gastric emptying

    International Nuclear Information System (INIS)

    Martin, J.L.; Beck, W.J.; McDonald, A.P.; Carlson, G.M.; Mathias, J.R.

    1983-01-01

    A solid-phase meal labeled with /sup 99m/Tc-sulfur colloid provides an improved clinical test for the quantitative evaluation of human gastric emptying. We studied 12 healthy male controls and five male patients with known gastric stasis secondary to a vagotomy and drainage procedure. All subjects were fasted for 8 hours before the study, and each consumed an unbuttered biscuit and a poached egg white containing 1 mCi of /sup 99m/Tc-sulfur colloid. For 2 hours, 60-second counts were measured every 10 minutes by a Pho Gamma III scintillation camera. The t 1 / 2 for control subjects was 60 minutes, at which time patients with gastric stasis had retained 98% of the test meal. At 120 minutes, control subjects and patients with gastric stasis had 4.7% and 89%, respectively, of the meal remaining in the stomach. The solid-phase test meal labeled with /sup 99m/Tc-sulfur colloid is easy to perform and can be used clinically to quantitatively measure gastric emptying in humans. This test can discriminate between control subjects and patients with known gastric stasis

  4. DGT Passive Sampling for Quantitative in Situ Measurements of Compounds from Household and Personal Care Products in Waters.

    Science.gov (United States)

    Chen, Wei; Li, Yanying; Chen, Chang-Er; Sweetman, Andrew J; Zhang, Hao; Jones, Kevin C

    2017-11-21

    Widespread use of organic chemicals in household and personal care products (HPCPs) and their discharge into aquatic systems means reliable, robust techniques to monitor environmental concentrations are needed. The passive sampling approach of diffusive gradients in thin-films (DGT) is developed here and demonstrated to provide in situ quantitative and time-weighted average (TWA) measurement of these chemicals in waters. The novel technique is developed for HPCPs, including preservatives, antioxidants and disinfectants, by evaluating the performance of different binding agents. Ultrasonic extraction of binding gels in acetonitrile gave good and consistent recoveries for all test chemicals. Uptake by DGT with HLB (hydrophilic-lipophilic-balanced) as the binding agent was relatively independent of pH (3.5-9.5), ionic strength (0.001-0.1 M) and dissolved organic matter (0-20 mg L -1 ), making it suitable for applications across a wide range of environments. Deployment time and diffusion layer thickness dependence experiments confirmed DGT accumulated chemicals masses are consistent with theoretical predictions. The technique was further tested and applied in the influent and effluent of a wastewater treatment plant. Results were compared with conventional grab-sampling and 24-h-composited samples from autosamplers. DGT provided TWA concentrations over up to 18 days deployment, with minimal effects from biofouling or the diffusive boundary layer. The field application demonstrated advantages of the DGT technique: it gives in situ analyte preconcentration in a simple matrix, with more quantitative measurement of the HPCP analytes.

  5. Effect of attenuation by the cranium on quantitative SPECT measurements of cerebral blood flow and a correction method

    International Nuclear Information System (INIS)

    Iwase, Mikio; Kurono, Kenji; Iida, Akihiko.

    1998-01-01

    Attenuation correction for cerebral blood flow SPECT image reconstruction is usually performed by considering the head as a whole to be equivalent to water, and the effects of differences in attenuation between subjects produced by the cranium have not been taken into account. We determined the differences in attenuation between subjects and assessed a method of correcting quantitative cerebral blood flow values. Attenuations by head on the right and left sides were measured before intravenous injection of 123 I-IMP, and water-converted diameters of both sides (Ta) were calculated from the measurements obtained. After acquiring SPECT images, attenuation correction was conducted according to the method of Sorenson, and images were reconstructed. The diameters of the right and left sides in the same position as the Ta (Tt) were calculated from the contours determined by threshold values. Using Ts given by 2 Ts=Ta-Tt, the correction factor λ=exp(μ 1 Ts) was calculated and multiplied as the correction factor when rCBF was determined. The results revealed significant differences between Tt and Ta. Although no gender differences were observed in Tt, they were seen in both Ta and Ts. Thus, interindividual differences in attenuation by the cranium were found to have an influence that cannot be ignored. Inter-subject correlation is needed to obtain accurate quantitative values. (author)

  6. /sup 99m/Tc-labeled solid-phase meal: a quantitative clinical measurement of human gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Martin, J.L.; Beck, W.J.; McDonald, A.P.; Carlson, G.M.; Mathias, J.R.

    1983-08-01

    A solid-phase meal labeled with /sup 99m/Tc-sulfur colloid provides an improved clinical test for the quantitative evaluation of human gastric emptying. We studied 12 healthy male controls and five male patients with known gastric stasis secondary to a vagotomy and drainage procedure. All subjects were fasted for 8 hours before the study, and each consumed an unbuttered biscuit and a poached egg white containing 1 mCi of /sup 99m/Tc-sulfur colloid. For 2 hours, 60-second counts were measured every 10 minutes by a Pho Gamma III scintillation camera. The t/sup 1///sup 2/ for control subjects was 60 minutes, at which time patients with gastric stasis had retained 98% of the test meal. At 120 minutes, control subjects and patients with gastric stasis had 4.7% and 89%, respectively, of the meal remaining in the stomach. The solid-phase test meal labeled with /sup 99m/Tc-sulfur colloid is easy to perform and can be used clinically to quantitatively measure gastric emptying in humans. This test can discriminate between control subjects and patients with known gastric stasis.

  7. Differences in quantitative methods for measuring subjective cognitive decline - results from a prospective memory clinic study

    DEFF Research Database (Denmark)

    Vogel, Asmus; Salem, Lise Cronberg; Andersen, Birgitte Bo

    2016-01-01

    influence reports of cognitive decline. METHODS: The Subjective Memory Complaints Scale (SMC) and The Memory Complaint Questionnaire (MAC-Q) were applied in 121 mixed memory clinic patients with mild cognitive symptoms (mean MMSE = 26.8, SD 2.7). The scales were applied independently and raters were blinded...... decline. Depression scores were significantly correlated to both scales measuring subjective decline. Linear regression models showed that age did not have a significant contribution to the variance in subjective memory beyond that of depressive symptoms. CONCLUSIONS: Measures for subjective cognitive...... decline are not interchangeable when used in memory clinics and the application of different scales in previous studies is an important factor as to why studies show variability in the association between subjective cognitive decline and background data and/or clinical results. Careful consideration...

  8. Use of dew-point detection for quantitative measurement of sweating rate

    Science.gov (United States)

    Brengelmann, G. L.; Mckeag, M.; Rowell, L. B.

    1975-01-01

    A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

  9. Bone health measured using quantitative ultrasonography in adult males with muscular dystrophy.

    Science.gov (United States)

    Morse, C I; Smith, J; Denny, A; Tweedale, J; Searle, N D; Winwood, K; Onambele-Pearson, G L

    2016-12-14

    To compare muscle and bone health markers in adult males (aged 20-59 yrs) with and without muscular dystrophy (MD). Participants included 11 Fascioscapulohumeral (FSH), 11 Becker's (Be), 9 limb girdle (LG), 11 Duchenne (DMD), and 14 non-dystrophic controls (CTRL). Physical activity was assessed using Bone (BPAQ) and disability specific (PASIPD) questionnaires. Bone QUS provided T- and Z scores from the Distal Radius (DR) and Mid-shaft tibia (MST). Tibialis anterior cross sectional area (TA ACSA ) was measured using B-mode ultrasound. Grip strength was measured in all but DMD. Physical activity was lower in DMD, FSH and BeMD than CTRL (PPASIPD correlated with grip strength (r=0.65, P<0.01) and TA ACSA (r=0.46, P<0.01). Muscle size, strength, and bone health was lower in adult males with MD compared to adult males without MD, the extent of this is partially determ