WorldWideScience

Sample records for discharge parameter study

  1. Study of the external parameters influence on the channel discharge radius in Hg lamps

    Cristea, M.

    2000-01-01

    In this paper, the plasma electric conductivity and the channel radius for high-pressure mercury arc discharge are calculated. The examined model emphasizes some correlations between various external parameters (current intensity, silicon tube diameter and working pressure) and the channel discharge radius. After model validation, the temperature distribution in the discharge zone is obtained and then the electrons and ions distribution, the electric carriers mobility and the electric conductivity for different lamp characteristics are calculated. The applied numerical simulation shows a linear increase of the channel radius with the tube radius Rw increasing, and a very week pressure dependence (in the range 0.5 - 5 atm.)

  2. Analysis of groundwater discharge with a lumped-parameter model, using a case study from Tajikistan

    Pozdniakov, S. P.; Shestakov, V. M.

    A lumped-parameter model of groundwater balance is proposed that permits an estimate of discharge variability in comparison with the variability of recharge, by taking into account the influence of aquifer parameters. Recharge-discharge relationships are analysed with the model for cases of deterministic and stochastic recharge time-series variations. The model is applied to study the temporal variability of groundwater discharge in a river valley in the territory of Tajikistan, an independent republic in Central Asia. Résumé Un modèle global de bilan d'eau souterraine a été développé pour estimer la variabilité de l'écoulement par rapport à celle de la recharge, en prenant en compte l'influence des paramètres de l'aquifère. Les relations entre recharge et écoulement sont analysées à l'aide du modèle pour des variations des chroniques de recharge soit déterministes, soit stochastiques. Le modèle est appliquéà l'étude de la variabilité temporelle de l'écoulement souterrain vers une rivière, dans le Tadjikistan, une république indépendante d'Asie centrale. Resumen Se propone un modelo de parámetros concentrados para realizar el balance de aguas subterráneas, el cual permite estimar la variabilidad en la descarga con respecto a la variabilidad en la recarga, en función de los parámetros que caracterizan el acuífero. Las relaciones entre recarga y descarga se analizan con el modelo para distintos casos de series temporales de recarga, tanto deterministas como estocásticas. El modelo se aplica al estudio de la variabilidad temporal de la descarga en un valle aluvial de Tadyikistán, una república independiente del Asia Central.

  3. [Study on plasma parameters in diffuse discharge with semispherical electrod by optical emission spectrum].

    Dong, Li-Fang; Tong, Guo-Liang; Shen, Zhong-Kai; Liu, Liang; Ji, Ya-Fei; Zhao, Huan-Huan

    2012-06-01

    The diffuse discharge plasma in air was observed in a dielectric barrier discharge with two semispherical water electrodes. The variations of vibration temperature, rotation temperature, and average electron energy as the function of the applied voltage were studied by emission spectroscopy. The vibration temperature and the rotation temperature were calculated through the second positive band system (C3Pi(u)-->B3Pi(g)) of N2+ and the first negative band system (B2 Sigma(u+)-->Chi2Sigma(g+)) of N(2+) respectively. The average electron energy was studied by intensity ratio of 391.4 and 337.1 nm. It was found that the rotation temperature increases with the applied voltage increasing, while the vibration temperature and the electron energy decrease.

  4. Preparation of Ag/Cu/Ti Nanofluids by Spark Discharge System and Its Control Parameters Study

    Kuo-Hsiung Tseng

    2015-01-01

    Full Text Available This study selected silver, copper, and titanium as the research objects to explore the relationship between nanofluids properties and electrical discharge machining (EDM processes. Regarding the products, UV-visible spectroscopy (UV-Vis was applied to measure the concentration distribution of nanofluids; zeta-size analysis is applied for measuring nanometal particles’ Zeta-Potential and the size distribution of metallic particles in the fluid. Finally, various instruments, including scanning electron microscope (SEM, were applied to observe the shape, size, and composition ratio of metal particles after processing. According to the experimental results, the control of the discharge pulse time, in addition to affecting the concentration of metallic liquid and temperature in the process, affects the size of the metal particles after the process. As the resistivity of silver and copper is very low, at about 15×10-9 Ω·m, if TON is set to between 10~50 μs, good preparation efficiency can be obtained. The resistivity of titanium is 420×10-9 Ω·m, which is much larger than that of silver or copper. Hence, TON should be set to approximately 100 μs to achieve a good discharge success rate.

  5. Experimental study on Response Parameters of Ni-rich NiTi Shape Memory Alloy during Wire Electric Discharge Machining

    Bisaria, Himanshu; Shandilya, Pragya

    2018-03-01

    Nowadays NiTi SMAs are gaining more prominence due to their unique properties such as superelasticity, shape memory effect, high fatigue strength and many other enriched physical and mechanical properties. The current studies explore the effect of machining parameters namely, peak current (Ip), pulse off time (TOFF), and pulse on time (TON) on wire wear ratio (WWR), and dimensional deviation (DD) in WEDM. It was found that high discharge energy was mainly ascribed to high WWR and DD. The WWR and DD increased with the increase in pulse on time and peak current whereas high pulse off time was favourable for low WWR and DD.

  6. Plasma diagnostics discharge parameters and chemistry

    Auciello, Orlando

    1989-01-01

    Plasma Diagnostics, Volume 1: Discharge Parameters and Chemistry covers seven chapters on the important diagnostic techniques for plasmas and details their use in particular applications. The book discusses optical diagnostic techniques for low pressure plasmas and plasma processing; plasma diagnostics for electrical discharge light sources; as well as Langmuir probes. The text also describes the mass spectroscopy of plasmas, microwave diagnostics, paramagnetic resonance diagnostics, and diagnostics in thermal plasma processing. Electrical engineers, nuclear engineers, microwave engineers, che

  7. Study on the effect of hydrogen addition on the variation of plasma parameters of argon-oxygen magnetron glow discharge for synthesis of TiO2 films

    Partha Saikia

    2016-04-01

    Full Text Available We report the effect of hydrogen addition on plasma parameters of argon-oxygen magnetron glow discharge plasma in the synthesis of H-doped TiO2 films. The parameters of the hydrogen-added Ar/O2 plasma influence the properties and the structural phases of the deposited TiO2 film. Therefore, the variation of plasma parameters such as electron temperature (Te, electron density (ne, ion density (ni, degree of ionization of Ar and degree of dissociation of H2 as a function of hydrogen content in the discharge is studied. Langmuir probe and Optical emission spectroscopy are used to characterize the plasma. On the basis of the different reactions in the gas phase of the magnetron discharge, the variation of plasma parameters and sputtering rate are explained. It is observed that the electron and heavy ion density decline with gradual addition of hydrogen in the discharge. Hydrogen addition significantly changes the degree of ionization of Ar which influences the structural phases of the TiO2 film.

  8. Towards optimization of experimental parameters for studying Li-O2 battery discharge products in TEM using in situ EELS.

    Basak, Shibabrata; Jansen, Jacob; Kabiri, Yoones; Zandbergen, Henny W

    2018-05-01

    The key to understanding the performance of Li-O 2 batteries is to study the chemical and structural properties of their discharge product(s) at the nanometer scale. Using TEM for this purpose poses challenges due to the sensitivity of samples to air and electron beams. This paper describes our use of in situ EELS to evaluate experimental procedures to reduce electron-beam degradation and presents methods to deal with air sensitivity. Our results show that Li 2 O 2 decomposition is dependent on the total dose and is approximately 4-5 times more pronounced at 80 than at 200 kV. We also demonstrate the benefits of using low-dose-rate STEM. We show further that a "graphene cell", which encapsulates the sample within graphene sheets, can protect the sample against air and e-beam damage. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. A study of the convective flow as a function of external parameters in a high-pressure metal halide discharge lamp (HgDyI{sub 3})

    Hajji, S.; HadjSalah, S.; Benhalima, A.; Charrada, K. [Unité d' Etude des Milieux Ionisés et Réactifs, IPEIM, 5019 route de Kairouan Monastir, Université de Monastir (Tunisia); Zissis, G. [Laboratoire Plasma et Conversion d' Énergie, 118 rte Narbonne, Bât3R2, 31062 Toulouse (France)

    2016-06-15

    This paper deals with the modelling of the convection processes in metal–halide lamp discharges (HgDyI{sub 3}). For this, we realized a 3D model, a steady, direct current powered and time-depending model for the solution of conservation equations relative to mass, momentum, and energy. After validation, this model was applied to the study of the effect of some parameters that have appeared on major transport phenomena of mass and energy in studying the lamp. Indeed, the electric current, the atomic ratio (Hg/Dy), and the effect of the convective transport have been studied.

  10. A study of the convective flow as a function of external parameters in a high-pressure metal halide discharge lamp (HgDyI3)

    Hajji, S.; HadjSalah, S.; Benhalima, A.; Charrada, K.; Zissis, G.

    2016-06-01

    This paper deals with the modelling of the convection processes in metal-halide lamp discharges (HgDyI3). For this, we realized a 3D model, a steady, direct current powered and time-depending model for the solution of conservation equations relative to mass, momentum, and energy. After validation, this model was applied to the study of the effect of some parameters that have appeared on major transport phenomena of mass and energy in studying the lamp. Indeed, the electric current, the atomic ratio (Hg/Dy), and the effect of the convective transport have been studied.

  11. Study of gliding arc discharge plasma

    Yang Chi; Lin Lie; Wu Bin

    2006-01-01

    The electric parameters change during discharge is studied and the relationship between non-equilibrium degree and parameters is discussed for gliding arc discharges. Using two-channel model, the rules of arc moving due to effect of the airflow is simulated. The numerical simulation results can help analyzing the generation mechanism of gliding arc non-equilibrium plasma. (authors)

  12. Coaxial discharge plasma parameters and radiation emission

    Solimen, H.M.

    1993-01-01

    Results are reported for experiments carried out on a Mather type coaxial discharge plasma device. Experimental measurements of the electron temperature and density for the plasma propagated from the coaxial discharge are determined by using a biased double electric probe. The experimental results illustrated that , there are two groups of the plasma in the ejected plasma bulk, at 9 cm from the muzzle axis, the plasma reached the probe at 20 μsec from the start of discharge. The first group has electron temperature and density 27 eV and 3 x 10 14 cm -3 respectively,while The second group has 25 eV and 3 x 10 14 cm -3 respectively. The decay rate of the electron temperature and density of each group is presented. The plasma radiation spectrum is detected by a dielectric filter at 3500 A degree or 6100 A degree . The experimental measurements showed that, without or with dielectric filters, the visible radiation consists from two pulses with different magnitudes within the same half cycle of discharge. The time resolution of the soft x-ray is achieved by means of scintillator detector. The detected x-ray pulse during the first half cycle of discharge had a double peaks with different structures. All the experimental results present in this paper showed that the plasma bulk propagated in the expansion chamber, consists of two-groups. 6 fig

  13. On the distribution of plasma parameters in RF glow discharge

    Ning Cheng; Liu Zuli; Liu Donghui; Han Caiyuan.

    1993-01-01

    A self-consistent numerical model based on the two-fluid equations for describing the transport of charged particles in the RF glow discharge is presented. For a plasma generator filled with low-pressure air and parallel-plate electrodes, the model is numerical solved. The space-time distribution of parameters and the spatial distribution of some time-averaged parameters in plasma, which show the physical picture of the RF glow discharge, are obtained

  14. A distributed parameter wire model for transient electrical discharges

    Maier, W.B. II; Kadish, A.; Sutherland, C.D.; Robiscoe, R.T.

    1990-01-01

    A model for freely propagating transient electrical discharges, such as lightning and punch-through arcs, is developed in this paper. We describe the electromagnetic fields by Maxwell's equations and we represent the interaction of electric fields with the medium to produce current by ∂J/∂t=ω 2 (E-E*J)/4π, where ω and E* are parameters characteristic of the medium, J≡current density, and J≡J/|J|. We illustrate the properties of this model for small-diameter, guided, cylindrically symmetric discharges. Analytic, numerical, and approximate solutions are given for special cases. The model describes, in a new and comprehensive fashion, certain macroscopic discharge properties, such as threshold behavior, quenching and reignition, path tortuosity, discharge termination with nonzero charge density remaining along the discharge path, and other experimentally observed discharge phenomena. Fields, current densities, and charge densities are quantitatively determined from given boundary and initial conditions. We suggest that many macroscopic discharge properties are properly explained by the model as electromagnetic phenomena, and we discuss extensions of the model to include chemistry, principally ionization and recombination

  15. Three dimensional numerical study of different parameters effect on the external magnetic field applied to center the arc of the horizontal mercury discharge lamp

    Mohamed Bechir Ben Hamida

    2015-10-01

    Full Text Available The aim of this paper is to evaluate the magnitude of the external magnetic field to be applied to a horizontal mercury discharge lamp such that the Lorentz forces counterbalance buoyancy forces and the hot region of the arc remains centered inside the lamp with the variation of six parameters of the lamp such as the external temperature of the lamp, envelope thickness, convective loss, Interelectrodeslength, pressure and current supply pointing to the influence of the parameters to the compensating magnetic field value. To achieve this objective, a commercial numerical software “Comsol Multiphysics” is used to implement the model that solves the equations of mass, energy and momentum for laminar compressible flow combined with the Laplace equation for the plasma in a three dimensional.

  16. Decomposition of three volatile organic compounds by nanosecond pulsed corona discharge: Study of by-product formation and influence of high voltage pulse parameters

    Jarrige, Julien; Vervisch, Pierre

    2006-06-01

    Increasing concerns over atmospheric pollution has motivated research into technologies able to remove volatile organic compounds (VOC's) from gas streams. The aim of this paper is to understand the chemical and physical mechanisms implied in the decomposition of VOC's in a filamentary nonthermal plasma discharge. Experiments have been carried out on three pollutants (propane, propene, and isopropyl alcohol) in dry air at atmospheric pressure using a wire to cylinder corona discharge generated by a homemade nanosecond rise time high voltage pulse generator. The resulting plasma efficiently destructs propane, propene, or isopropyl alcohol at a concentration of 500 ppm with low specific input energies (less than 500 J/L), but the poor oxidation rate leads to the formation of numerous by-products (acetone, formaldehyde, formic acid, and methyl nitrate) whose concentration can reach some hundreds of ppm. We also investigated the effect of pulse parameters on VOC removal efficiency. Neither pulse peak value nor rise time (in the range of 4-12 ns) appears to have a significant influence on the VOC decomposition rates. Therefore, we believe that the way the energy is deposited in the plasma does not modify the density of active species (radicals, ions) in the streamers. The production of energetic electrons is not enhanced by the external applied field, and the only effective parameter may be the local field in the streamer head, which is almost the same (around 500 Td) whatever the voltage (above the inception value).

  17. Decomposition of three volatile organic compounds by nanosecond pulsed corona discharge: Study of by-product formation and influence of high voltage pulse parameters

    Jarrige, Julien; Vervisch, Pierre

    2006-01-01

    Increasing concerns over atmospheric pollution has motivated research into technologies able to remove volatile organic compounds (VOC's) from gas streams. The aim of this paper is to understand the chemical and physical mechanisms implied in the decomposition of VOC's in a filamentary nonthermal plasma discharge. Experiments have been carried out on three pollutants (propane, propene, and isopropyl alcohol) in dry air at atmospheric pressure using a wire to cylinder corona discharge generated by a homemade nanosecond rise time high voltage pulse generator. The resulting plasma efficiently destructs propane, propene, or isopropyl alcohol at a concentration of 500 ppm with low specific input energies (less than 500 J/L), but the poor oxidation rate leads to the formation of numerous by-products (acetone, formaldehyde, formic acid, and methyl nitrate) whose concentration can reach some hundreds of ppm. We also investigated the effect of pulse parameters on VOC removal efficiency. Neither pulse peak value nor rise time (in the range of 4-12 ns) appears to have a significant influence on the VOC decomposition rates. Therefore, we believe that the way the energy is deposited in the plasma does not modify the density of active species (radicals, ions) in the streamers. The production of energetic electrons is not enhanced by the external applied field, and the only effective parameter may be the local field in the streamer head, which is almost the same (around 500 Td) whatever the voltage (above the inception value)

  18. Multi-Parameter Analysis of Surface Finish in Electro-Discharge Machining of Tool Steels

    Cornelia Victoria Anghel

    2006-10-01

    Full Text Available The paper presents a multi- parameter analysis of surface finish imparted to tool-steel plates by electro-discharge machining (EDM is presented. The interrelationship between surface texture parameters and process parameters is emphasized. An increased number of parameters is studied including amplitude, spacing, hybrid and fractal parameters,, as well. The correlation of these parameters with the machining conditions is investigated. Observed characteristics become more pronounced, when intensifying machining conditions. Close correlation exists between certain surface finish parameters and EDM input variables and single and multiple statistical regression models are developed.

  19. Effects of discharge parameters on the micro-hollow cathode sustained glow discharge

    Shoujie, HE; Peng, WANG; Jing, HA; Baoming, ZHANG; Zhao, ZHANG; Qing, LI

    2018-05-01

    The effects of parameters such as pressure, first anode radius, and the cavity diameter on the micro-hollow cathode sustained glow discharge are investigated by using a two-dimensional self-consistent fluid model in pure argon. The results indicate that the three parameters influence the discharge in the regions inside and outside of the cavity. Under a fixed voltage on each electrode, a larger volume of high density plasma can be produced in the region between the first and the second anodes by selecting the appropriate pressure, the higher first anode, and the appropriate cavity diameter. As the pressure increases, the electron density inside the hollow cathode, the high density plasma volume between the first anode and second anodes, and the radial electric field in the cathode cavity initially increase and subsequently decrease. As the cavity diameter increases, the high-density plasma volume between the first and second anodes initially increases and subsequently decreases; whereas the electron density inside the hollow cathode decreases. As the first anode radius increases, the electron density increases both inside and outside of the cavity. Moreover, the increase of the electron density is more obvious in the microcathode sustained region than in the micro cavity region. The results reveal that the discharge inside the cavity interacts with that outside the cavity. The strong hollow cathode effect and the high-density plasma inside the cavity favor the formation of a sustained discharge between the first anode and the second anodes. Results also show that the radial boundary conditions exert a considerably weaker influence on the discharge except for a little change in the region close to the radial boundary.

  20. Investigation of the helicon discharge plasma parameters in a hybrid RF plasma system

    Aleksandrov, A. F.; Petrov, A. K.; Vavilin, K. V.; Kralkina, E. A.; Neklyudova, P. A.; Nikonov, A. M.; Pavlov, V. B.; Ayrapetov, A. A.; Odinokov, V. V.; Sologub, V. A.; Pavlov, G. Ya.

    2016-01-01

    Results of an experimental study of the helicon discharge plasma parameters in a prototype of a hybrid RF plasma system equipped with a solenoidal antenna are described. It is shown that an increase in the external magnetic field leads to the formation of a plasma column and a shift of the maximum ion current along the discharge axis toward the bottom flange of the system. The shape of the plasma column can be controlled via varying the configuration of the magnetic field.

  1. Investigation of the helicon discharge plasma parameters in a hybrid RF plasma system

    Aleksandrov, A. F.; Petrov, A. K., E-mail: alpetrov57@gmail.com; Vavilin, K. V.; Kralkina, E. A.; Neklyudova, P. A.; Nikonov, A. M.; Pavlov, V. B. [Moscow State University, Faculty of Physics (Russian Federation); Ayrapetov, A. A.; Odinokov, V. V.; Sologub, V. A.; Pavlov, G. Ya. [Research Institute of Precision Engineering (Russian Federation)

    2016-03-15

    Results of an experimental study of the helicon discharge plasma parameters in a prototype of a hybrid RF plasma system equipped with a solenoidal antenna are described. It is shown that an increase in the external magnetic field leads to the formation of a plasma column and a shift of the maximum ion current along the discharge axis toward the bottom flange of the system. The shape of the plasma column can be controlled via varying the configuration of the magnetic field.

  2. Influence of discharge parameters on capillary discharge-pumped soft X-ray laser

    Peng Huimin; Zheng Wudi; Yang Dawei; Zhao Yongpeng; Cheng Yuanli; Wang Qi

    2005-01-01

    Based on the wave shape of Marx device at National Key Laboratory of Tunable Laser Technology, Harbin Institute of Technology, the influence of discharge parameters upon the temporal evolvement of capillary discharge produced plasmas conditions and the gain coefficient of 3p-3s transition in Neon-like Ar was simulated. In the simulation, argon with a density of 1.07 x 10 -6 g·cm -3 was filled into a ceramic capillary with an inner diameter of 3.1 mm, the peak of the discharge current pulse was 27.81 kA, and the width of the current pulse was 61.4 ns. The results show that the shorter the pulse rise time is, the higher the gain coefficient is. When the pulse rise time is 20-40 ns, the peak of the current pulse is 25-40 ns, and the current pulse width is 50-70 ns, the higher gain coefficient can be obtained. (authors)

  3. Study of a microwave discharge in argon/helium mixtures

    Saada, Serge

    1983-01-01

    A discharge created by a surface wave in Argon-Helium mixture is studied. First, the helium influence on plasma parameters has been studied (electron density, electric field, effective collision frequency, etc...), then, on excitation processes in the discharge. Relations between plasma lines, electron density and electric field have been established. [fr

  4. Influence of gas discharge parameters on emissions from a dielectric barrier discharge excited argon excimer lamp

    Mike Collier

    2011-11-01

    Full Text Available A dielectric barrier discharge excited neutral argon (Ar I excimer lamp has been developed and characterised. The aim of this study was to develop an excimer lamp operating at atmospheric pressure that can replace mercury lamps and vacuum equipment used in the sterilisation of medical equipment and in the food industry. The effects of discharge gas pressure, flow rate, excitation frequency and pulse width on the intensity of the Ar I vacuum ultraviolet (VUV emission at 126 nm and near infrared (NIR lines at 750.4 nm and 811.5 nm have been investigated. These three lines were chosen as they represent emissions resulting from de-excitation of excimer states that emit energetic photons with an energy of 9.8 eV. We observed that the intensity of the VUV Ar2* excimer emission at 126 nm increased with increasing gas pressure, but decreased with increasing excitation pulse frequency and pulse width. In contrast, the intensities of the NIR lines decreased with increasing gas pressure and increased with increasing pulse frequency and pulse width. We have demonstrated that energetic VUV photons of 9.8 eV can be efficiently generated in a dielectric barrier discharge in Ar.

  5. [Measurement of plasma parameters in cluster hexagon pattern discharge by optical emission spectrum].

    Dong, Li-Fang; Shen, Zhong-Kai; Li, Xin-Chun; Liu, Liang; Lu, Ning; Shang, Jie

    2012-09-01

    The cluster hexagon pattern was obtained in a dielectric barrier discharge in air/argon for the first time. Three plasma parameters, i. e. the molecular vibrational temperature, the molecular rotational temperature and the average electron energy of individual cluster in cluster hexagon pattern discharge, were studied by changing the air content. The molecular vibrational temperature and the molecular rotational temperature were calculated using the second positive band system of nitrogen molecules (C 3IIu --> B 3IIg) and the first negative band system of nitrogen molecular ions (B 2Sigma(u)+ --> Chi2 Sigma(g)+). The relative intensities of the first negative system of nitrogen molecular ions (391. 4 nm) and nitrogen molecules emission spectrum line (337.1 nm) were analyzed for studying the variations of the electron energy. It was found that the three plasma parameters of individual cluster in cluster hexagon pattern increase with air content increasing from 16% to 24%.

  6. Cathode fall parameters of a self-sustained normal glow discharge in atmospheric-pressure helium

    Arkhipenko, V.I.; Zgirovskii, S.M.; Kirillov, A.A.; Simonchik, L.V.

    2002-01-01

    Results from comprehensive studies of a high-current self-sustained glow discharge in atmospheric-pressure helium are presented. The main parameters of the cathode fall, namely, the electric field profile, cathode fall thickness, current density, gas temperature, and heat flux to the cathode are determined. The results obtained are discussed using one-dimensional models of the cathode fall with allowance for volumetric heat release

  7. Parameters of the constricted plasma discharge produced by radio-frequency for atmospheric pressures

    Zambrano R, G.

    1987-01-01

    The main electrophysical characteristics of high-frequency discharge between two electrodes for pressures of the order of atmospheric pressure were investigated. The vibrational and kinetic temperatures of the discharge, and the possibilities for creating the conditions which using these type of discharge an instability between vibrational and kinetic temperatures can be obtained. For determining main characteristics of this type of discharge, argon gas, nitrogen gas and air, when oxygen and nitrogen are predominated, were used. The obtained electrical discharge parameters were: the high frequency voltage between electrocathodes, the current, the phase displacement between current and voltage, and the discharge power. The kinetic temperature distribution in the discharge region, and the vibrational temperature of the nitrogen molecules in discharge channel were also obtained. (M.C.K.) [pt

  8. Mode transition of power dissipation and plasma parameters in an asymmetric capacitive discharge

    Lee, Soo-Jin; Lee, Hyo-Chang; Bang, Jin-young; Oh, Seung-Ju; Chung, Chin-Wook

    2013-01-01

    Electrical characteristics and plasma parameters were experimentally investigated in asymmetric capacitively coupled plasma with various argon gas pressures. At a low discharge current region, the transferred power to the plasma was proportional to the current, while the transferred power increased proportionally to square of the current at a high discharge current region. The mode transition of power dissipation occurred at the lower discharge current region with the high gas pressure. At the low radio-frequency power or low discharge current, the plasma density increased linearly with the discharge current, while at the high power or high discharge current, the rate of an increase in the plasma density depended on the gas pressures. A transition of the discharge resistance was also found when the mode transition of the power dissipation occurred. These changes in the electrical characteristics and the plasma parameters were mainly caused by the power dissipation mode transition from the plasma bulk to the sheath in the capacitive discharge with the asymmetric electrode, which has extremely high self-bias voltages. - Highlights: • Mode transition of the power dissipation in an asymmetrical capacitive discharge • Evolution of the discharge power, electrode voltage, and discharge impedance • Electron temperature and plasma density on the power dissipation mode transition

  9. Characterization of plasma parameters in shaped PBX-M discharges

    England, A. C.; Bell, R. E.; Hirshman, S. P.; Kaita, R.; Kugel, H. W.; LeBlanc, B. L.; Lee, D. K.; Okabayashi, M.; Sun, Y.-C.; Takahashi, H.

    1997-09-01

    The Princeton Beta Experiment-Modification (PBX-M) was run both with elliptical and with bean-shaped plasmas during the 1992 and 1993 operating periods. Two deuterium-fed neutral beams were used for auxiliary heating, and during 1992 the average power was 0741-3335/39/9/008/img13. This will be referred to as the lower neutral-beam power (LNBP) period. As many as four deuterium-fed neutral beams were used during 1993, and the average power was 0741-3335/39/9/008/img14. This will be referred to as the medium neutral-beam power (MNBP) period. The neutron source strength, Sn, showed a scaling with injected power 0741-3335/39/9/008/img15, 0741-3335/39/9/008/img16 for both the LMBP and MNBP periods. A much wider range of shaping parameters was studied during the MNBP as compared with the LNBP period. A weak positive dependence on bean shaping was observed for the LNBP, and a stronger positive dependence on shaping was observed for MNBP, viz 0741-3335/39/9/008/img17. High values of Sn were obtained in bean-shaped plasmas for the highest values of 0741-3335/39/9/008/img18 at 0741-3335/39/9/008/img19 for the LNBP. For the MNBP the highest values of Sn and stored energy were obtained at 0741-3335/39/9/008/img19, and the highest values of 0741-3335/39/9/008/img18 were obtained at 0741-3335/39/9/008/img22. The achievement of high Sn is aided by high neutral-beam power, high toroidal field, strong shaping, high electron temperature, and broad profiles. The achievement of high 0741-3335/39/9/008/img18 is aided by low toroidal field, high density, less shaping, broad profiles, and access to the H-mode, viz 0741-3335/39/9/008/img24. The achievement of high 0741-3335/39/9/008/img25 is aided by strong shaping, high density, broad profiles, and access to the H-mode, viz 0741-3335/39/9/008/img26. Some comparisons with the previous higher neutral-beam (HNBP) period in 1989 are also made.

  10. Radio frequency glow discharge source with integrated voltage and current probes used for evaluation of discharge parameters

    Wilken, L.; Hoffmann, V.; Wetzig, K.

    2006-01-01

    A radio frequency (rf) Grimm-type glow discharge source for the chemical analysis of solid samples, with integrated voltage and current probes, was developed. All elements of a plasma equivalent circuit are determined from the measured current-voltage characteristics. The procedure is based on the independent evaluation of the ion current and electron current region. The physical meaning of the parameters is investigated by comparisons with measurements from dc glow discharges. We found that the reduced rf current of the powered electrode is comparable to the reduced current in dc discharges. A formula is developed that corrects the reduced current due to gas heating. The sheath thickness at the powered rf electrode is evaluated and is between 75 and 1100 μm. The voltage of the bulk plasma is in the range 2-15 V, and the resistance is between 30 and 400 Ω. The bulk plasma consumes about 3% of the total power, and the reduced voltage is comparable to the reduced electrical field in the positive column of direct current discharges. The sheath voltage at the grounded electrode is in the range 25-100 V, the capacities are between 10 and 400 pF, and the resistances are in the range 100 Ω-5000 Ω. We also found invariants for the evaluated sheath parameters

  11. Study on the hydrogen negative ion in low pressure discharges

    Bruneteau, A.M.

    1983-07-01

    A new use of negative hydrogen ions is the production of intense fast neutral atom beams useful in plasma heating in thermonuclear heating. That is one of the reasons that started this study. The density of negative hydrogen ions in diffusion, and multipole-type low pressure (10 -3 - 10-2 Torr) discharges is deduced from the various formation and destruction processes of the species present in these discharges. The H - ions are essentially produced by dissociative attachment to vibrationally excited molecules and destroyed by processes the relative importance of which is discussed as a function of the discharge parameters. The experimental study of the density of the H - ions, measured by photodetachment, as a function of these parameters, coroborates the theoretical model [fr

  12. Study and optimization of the partial discharges in capacitor model ...

    Page 1 ... experiments methodology for the study of such processes, in view of their modeling and optimization. The obtained result is a mathematical model capable to identify the parameters and the interactions between .... 5mn; the next landing is situated in 200 V over the voltage of partial discharges appearance and.

  13. Gas and plasma dynamics of RF discharge jet of low pressure in a vacuum chamber with flat electrodes and inside tube, influence of RF discharge on the steel surface parameters

    Khristoliubova, V. I.; Kashapov, N. F.; Shaekhov, M. F.

    2016-06-01

    Researches results of the characteristics of the RF discharge jet of low pressure and the discharge influence on the surface modification of high speed and structural steels are introduced in the article. Gas dynamics, power and energy parameters of the RF low pressure discharge flow in the discharge chamber and the electrode gap are studied in the presence of the materials. Plasma flow rate, discharge power, the concentration of electrons, the density of RF power, the ion current density, and the energy of the ions bombarding the surface materials are considered for the definition of basic properties crucial for the process of surface modification of materials as they were put in the plasma jet. The influence of the workpiece and effect of products complex configuration on the RF discharge jet of low pressure is defined. The correlation of the input parameters of the plasma unit on the characteristics of the discharge is established.

  14. Charging/discharging processes in nanocrystaline MOS structures - Theoretical study

    Tanous, D; Mazurak, A; Majkusiak, B

    2016-01-01

    We present the study of impact of some parameters of the metal-insulator-semiconductor structure with nanocrystals embedded in the insulator layer on the current-voltage and capacitance-voltage characteristics with the bias voltage ramp rate as a parameter. The developed model is used as a tool for theoretical understanding the physics behind charging and discharging processes in the considered structures. (paper)

  15. Catalytic aided electrical discharge machining of polycrystalline diamond - parameter analysis of finishing condition

    Haikal Ahmad, M. A.; Zulafif Rahim, M.; Fauzi, M. F. Mohd; Abdullah, Aslam; Omar, Z.; Ding, Songlin; Ismail, A. E.; Rasidi Ibrahim, M.

    2018-01-01

    Polycrystalline diamond (PCD) is regarded as among the hardest material in the world. Electrical Discharge Machining (EDM) typically used to machine this material because of its non-contact process nature. This investigation was purposely done to compare the EDM performances of PCD when using normal electrode of copper (Cu) and newly proposed graphitization catalyst electrode of copper nickel (CuNi). Two level full factorial design of experiment with 4 center points technique was used to study the influence of main and interaction effects of the machining parameter namely; pulse-on, pulse-off, sparking current, and electrode materials (categorical factor). The paper shows interesting discovery in which the newly proposed electrode presented positive impact to the machining performance. With the same machining parameters of finishing, CuNi delivered more than 100% better in Ra and MRR than ordinary Cu electrode.

  16. ATLAS parameter study

    Adler, R.J.

    1994-01-01

    The purpose of this study is to make an independent assessment on the parameters chosen for the ATLAS capacitor bank at LANL. The contractor will perform a study of the basic pulsed power parameters of the ATLAS device with baseline functional parameters of >25 MA implosion current and <2.5 microsecond current risetime. Nominal circuit parameters held fixed will be the 14 nH from the vacuum interface to the load, and the nominal load impedances of 1 milliohm for slow loads and 10 milliohms for fast loads. Single Ended designs, as opposed to bipolar designs, will be studied in detail. The ATLAS pulsed power design problem is about inductance. The reason that a 36 MJ bank is required is that such a bank has enough individual capacitors so that the parallel inductance is acceptably low. Since about half the inductance is in the bank, and the inductance and time constant of the submodules is fixed, the variation of output with a given parameter will generally be a weak one. In general, the dl/dt calculation demonstrates that for the real system inductances, 700 kV is the optimum voltage for the bank to drive X-ray loads. The optimum is broad, and there is little reduction in performance at voltages as low as 450 kV. The direct drive velocity analysis also shows that the optimum velocity is between 480 and 800 kV for a variety of assumptions, and that there is less than a 10% variation in velocity over this range. Voltages in the 120 kV--600 kV range are desirable for driving heavy liners. A compromise optimum operating point might be 480 kV, at which all X-ray operation scenarios are within 10% of their velocity optimum, and heavy liners can be configured to be near optimum if small enough. Based on very preliminary studies the author believes that the choice of a single operating voltage point (say, 480 kV) is unnecessary, and that a bank engineered for dual operation at 480 and 240 kV will be the best solution to the ATLAS problem

  17. Assessment of the impact of a parameter estimation method for the Nash Model on selected parameters of a catchment discharge hydrograph

    Kołodziejczyk Katarzyna

    2017-01-01

    Full Text Available An analysis of the usefulness of two parameter calculation methods (N and k parameters for the Nash Model was performed to transform effective rainfall into discharge based on two rainfall episodes gauged at the Kostrze gauging station as well as urban development data for the city of Cracow for 2014 and data obtained from a soil and agriculture map. The methods were the Rao et al. method and the Bajkiewicz-Grabowska method for regression relationships between instantaneous unit hydrograph model parameters and the physiographic parameters of a catchment. Effective rainfall was calculated for each rainfall episode using the SCS-CN method. A direct discharge hydrograph was calculated based on an effective rainfall hyetograph and using the Nash Model. Research has found that both studied methods yield comparable results, which indicates that both methods of effective rainfall transformation into discharge are useful. In addition, it has been shown that the impact of the Nash Model parameter estimation method on discharge hydrographs is minimal.

  18. Parameters of the plasma of a dc pulsating discharge in a supersonic air flow

    Shibkov, V. M., E-mail: shibkov@phys.msu.ru; Shibkova, L. V.; Logunov, A. A. [Moscow State University, Faculty of Physics (Russian Federation)

    2017-03-15

    A dc discharge in a cold (T = 200 K) supersonic air flow at a static pressure of 200–400 Torr was studied experimentally. The excited unsteady pulsating discharge has the form of a thin plasma channel with a diameter of ≤1 mm, stretched downstream the flow. Depending on the discharge current, the pulsation frequency varies from 800 to 1600 Hz and the electron temperature varies from 8000 to 15000 K.

  19. Resistive MHD studies of TFTR discharges

    Hughes, M.H.; Phillips, M.W.; Sabbagh, S.A.; Budny, R.V.

    1991-01-01

    MHD instabilities, thought to be resistive in character, are frequently observed in the supershot operating regime of TFTR (var-epsilon β p ≤ 0.7). These instabilities are always accompanied by substantial degradation of the confinement. Similarly of interest are recent experiments at much larger β p (var-epsilon β p ≤ 1.6), achieved through ramping the current during the beam heating phase of the discharge. In this latter regime the confinement can exceed three times the corresponding L-mode value and the β value normalized to I/aB can be as large as 4.7. Representative discharges from each of these operating regimes have been analyzed using a linear resistive MHD stability code with equilibrium pressure and q profiles obtained initially from the TRANSP analysis code. The main difference between the two types of discharge, as far as stability is concerned is shown to be the shape of the current density profile. The sensitivity to the assumed parameters is discussed. 1 ref

  20. Spectroscopic study of ohmically heated Tokamak discharges

    Breton, C.; Michelis, C. de; Mattioli, M.

    1980-07-01

    Tokamak discharges interact strongly with the wall and/or the current aperture limiter producing recycling particles, which penetrate into the discharge and which can be studied spectroscopically. Working gas (hydrogen or deuterium) is usually studied observing visible Balmer lines at several toroidal locations. Absolute measurements allow to obtain both the recycling flux and the global particle confinement time. With sufficiently high resolution the isotopic plasma composition can be obtained. The impurity elements can be divided into desorbed elements (mainly oxygen) and eroded elements (metals from both walls and limiter) according to the plasma-wall interaction processes originating them. Space-and time-resolved emission in the VUV region down to about 20 A will be reviewed for ohmically-heated discharges. The time evolution can be divided into four phases, not always clearly separated in a particular discharge: a) the initial phase, lasting less than 10 ms (the so-called burn-out phase), b) the period of increasing plasma current and electron temperature, lasting typically 10 - 100 ms, c) an eventual steady state (plateau of the plasma current with almost constant density and temperature), d) the increase of the electron density up to or just below the maximum value attainable in a given device. For all these phases the results reported from different devices will be described and compared

  1. Study of a rare-gas transverse fast discharge

    Chubb, D. L.; Michels, C. J.

    1979-01-01

    An experimental and analytical study of a Blumlein-type transverse fast discharge operating with He and Xe are presented. An electro-optical voltage probe was used to measure the discharge voltage, and the measured voltages were in agreement with the computed voltages. The analytical model was used to predict the dependence of the discharge efficiency for producing metastables and ions on the important plasma and external circuit parameters. In He the ion efficiency is greater than the metastable efficiency, while in Xe it is the opposite; the He ion efficiencies are much larger than in Xe, while Xe metastable efficiencies are much larger than in He. These differences between Xe and He are accounted by the large dissociative recombination rate of Xe compared with He.

  2. Breakdown study of dc silicon micro-discharge devices

    Schwaederlé, L; Kulsreshath, M K; Lefaucheux, P; Tillocher, T; Dussart, R; Overzet, L J

    2012-01-01

    The influence of geometrical and operating parameters on the electrical characteristics of dc microcavity discharges provides insight into their controlling physics. We present here results of such a study on silicon-based microcavity discharge devices carried out in helium at pressure ranging from 100 to 1000 Torr. Different micro-reactor configurations were measured. The differences include isolated single cavities versus arrays of closely spaced cavities, various cavity geometries (un-etched as well as isotropically and anisotropically etched), various dimensions (100 or 150 µm cavity diameter and 0-150 µm depth). The electrode gap was kept constant in all cases at approximately 6 µm. The applied electric field reaches 5 × 10 7 V m -1 which results in current and power densities up to 2 A cm -2 and 200 kW cm -3 , respectively. The number of microcavities and the microcavity depth are shown to be the most important geometrical parameters for predicting breakdown and operation of microcavity devices. The probability of initiatory electron generation which is volume dependent and the electric field strength which is depth dependent are, respectively, considered to be responsible. The cavity shape (isotropic/anisotropic) and diameter had no significant influence. The number of micro-discharges that could be ignited depends on the rate of voltage rise and pressure. Larger numbers ignite at lower frequency and pressure. In addition, the voltage polarity has the largest influence on the electrical characteristics of the micro-discharge of all parameters, which is due to both the asymmetric role of electrodes as electron emitter and the non-uniformity of the electric field resulting in different ionization efficiencies. The qualitative shape of all breakdown voltage versus pressure curves can be explained in terms of the distance over which the discharge breakdown effectively occurs as long as one understand that this distance can depend on pressure. (paper)

  3. Parameters for Fabricating Nano-Au Colloids through the Electric Spark Discharge Method with Micro-Electrical Discharge Machining.

    Tseng, Kuo-Hsiung; Chung, Meng-Yun; Chang, Chaur-Yang

    2017-06-02

    In this study, the Electric Spark Discharge Method (ESDM) was employed with micro-electrical discharge machining (m-EDM) to create an electric arc that melted two electrodes in deionized water (DW) and fabricated nano-Au colloids through pulse discharges with a controlled on-off duration (T ON -T OFF ) and a total fabrication time of 1 min. A total of six on-off settings were tested under normal experimental conditions and without the addition of any chemical substances. Ultraviolet-visible spectroscopy (UV-Vis), Zetasizer Nano measurements, and scanning electron microscopy-energy dispersive X-ray (SEM-EDX) analyses suggested that the nano-Au colloid fabricated at 10-10 µs (10 µs on, 10 µs off) had higher concentration and suspension stability than products made at other T ON -T OFF settings. The surface plasmon resonance (SPR) of the colloid was 549 nm on the first day of fabrication and stabilized at 532 nm on the third day. As the T ON -T OFF period increased, the absorbance (i.e., concentration) of all nano-Au colloids decreased. Absorbance was highest at 10-10 µs. The SPR peaks stabilized at 532 nm across all T ON -T OFF periods. The Zeta potential at 10-10 µs was -36.6 mV, indicating that no nano-Au agglomeration occurred and that the particles had high suspension stability.

  4. [Study on Square Super-Lattice Pattern with Surface Discharge in Dielectric Barrier Discharge by Optical Emission Spectra].

    Niu, Xue-jiao; Dong, Li-fang; Liu, Ying; Wang, Qian; Feng, Jian-yu

    2016-02-01

    Square super-lattice pattern with surface discharge consisting of central spots and dim spots is firstly observed in the mixture of argon and air by using a dielectric barrier discharge device with water electrodes. By observing the image, it is found that the central spot is located at the centriod of its surrounding four dim spots. The short-exposure image recorded by a high speed video camera shows that the dim spot results from the surface discharges (SDs). The brightness of the central spot and is quite different from that of the dim spot, which indicates that the plasma states of the central spot and the dim spot may be differentiated. The optical emission spectrum method is used to further study the several plasma parameters of the central spot and the dim spot in different argon content. The emission spectra of the N₂ second positive band (C³IIu --> B³ IIg) are measured, from which the molecule vibration temperatures of the central spot and the dim spot are calculated respectively. The broadening of spectral line 696.57 nm (2P₂-->1S₅) is used to study the electron densities of the central spot and the dim spot. It is found that the molecule vibration temperature and electron density of the dim spot are higher than those of the central spot in the same argon content The molecule vibration temperature and electron density of the central spot and the dim spot increase with the argon content increasing from 90% to 99.9%. The surface discharge induced by the volume discharge (VD) has the determinative effect on the formation of the dim spot The experimental results above play an important role in studying the formation mechanism of surface discharg&of square super-lattice pattern with surface discharge. In addition, the studies exert an influence on the application of surface discharge and volume discharge in different fields.

  5. Basic Studies of Distributed Discharge Limiters

    2014-02-10

    electron avalanche ionization discharges induced by a focused 110 GHz millimeter-wave beam in atmospheric air. Discharges take place in a free volume of...plasma. 3.1.7 Vacuum Ultraviolet emission from pulsed discharges at atmospheric pressure. Fig. 6. Energy level diagram for molecular and...the utilized spectral simulation software, SPECTRAPLOT. 3.1.8 Non-intrusive diagnostic method for dissociation degree in pulsed discharges

  6. Parameter dependences of the separatrix density in nitrogen seeded ASDEX Upgrade H-mode discharges

    Kallenbach, A.; Sun, H. J.; Eich, T.; Carralero, D.; Hobirk, J.; Scarabosio, A.; Siccinio, M.; ASDEX Upgrade Team; EUROfusion MST1 Team

    2018-04-01

    The upstream separatrix electron density is an important interface parameter for core performance and divertor power exhaust. It has been measured in ASDEX Upgrade H-mode discharges by means of Thomson scattering using a self-consistent estimate of the upstream electron temperature under the assumption of Spitzer-Härm electron conduction. Its dependence on various plasma parameters has been tested for different plasma conditions in H-mode. The leading parameter determining n e,sep was found to be the neutral divertor pressure, which can be considered as an engineering parameter since it is determined mainly by the gas puff rate and the pumping speed. The experimentally found parameter dependence of n e,sep, which is dominated by the divertor neutral pressure, could be approximately reconciled by 2-point modelling.

  7. Numerical study on discharge process of microcavity plasma

    Xia Guangqing; Xue Weihua; Wang Dongxue; Zhu Guoqiang; Zhu Yu

    2012-01-01

    The evolution of plasma parameters during high pressure discharge in the microcavity with a hollow anode was numerically studied, with a two-dimensional self-consistent fluid model. The simulations were performed with argon at 13.3 kPa. The numerical results show that during the discharge the electric field around the cathode transforms from an axial field to a radial field, the plasma density gets the maximum value on the central line of the cavity and the location of the maximum density moves from the region near anode at the initial stage to the cathode vicinity at the stable stage, and the maximum electron temperature occurs in the ring sheath of cathode. (authors)

  8. Fundamental Study on Electrical Discharge Machining

    Uno, Yoshiyuki; Nakajima, Toshikatsu; Endo, Osamu

    1989-01-01

    The generation mechanism of crater in electrical discharge machining is analyzed with a single pulse discharge device for alloy tool steel, black alumina ceramics, cermet and cemented carbide, investigating the gap voltage, the discharge current, the shape of crater, the wear of electrode and so on. The experimental analysis makes it clear that the shape of crater has a characteristic feature for the kind of workpiece. The shape of electrode, which changes with the wear by an electric spark, ...

  9. About an 'electrical method' used in the study of gas discharge plasma

    Toma, M.

    1992-01-01

    It is known that in a gas discharge device the discharge current intensity can be modified by means of different control parameters such as discharge voltage bias, magnetic field strength and/or neutral gas pressure. The aim of this work is to point out that the interpretation of I d (U), I d (B), and I d (p) characteristics can be used as a suitable method for a qualitative study of the fundamental processes which take place in gas discharge devices in different experimental conditions. A unified point of view on the jumps and hysteresis in discharge current produced by varying the control parameters in different discharge configurations, is given. The behaviour can be explained by taking into account the self-organization processes related with the generation and disruption of space charge structure. (Author)

  10. Design parameter based method of partial discharge detection and location in power transformers

    Kumar Santosh Annadurai

    2009-01-01

    Full Text Available Insulation defect detection in time ensures higher operational reliability of power system assets. Power transformers are the most critical unit of power systems both from economical and operational front. Hence it becomes necessary to have knowledge of the actual insulation condition of transformer to increase dependability of the system. The performance and ageing of the transformer insulation is mainly affected by Partial discharges (PD. Proper diagnosis in terms of amplitude and location of partial discharge in a power transformer enables us to predict well in advance, with much confidence, the defect in insulation system, which avoids large catastrophic failures. In this work a 20kVA, 230/50kV single phase core type transformer is used for evaluation of the transfer function-based partial discharge detection and location using modeling of the winding, using design data. The simulation of capturing on-line PD pulses across the bushing tap capacitor is done for various tap positions. Standard PD source model is used to inject PD pulse signal at 10 tap locations in the winding and corresponding response signatures are captured at the bushing tap end (across 1000pF. The equivalent high frequency model of the winding is derived from the design parameters using analytical calculations and simulations in packages such as MAGNET and ANSOFT. The test conditions are simulated using ORCAD-9 and the results are evaluated for location accuracy using design parameter based PD monitoring method. .

  11. Using sensitivity derivatives for design and parameter estimation in an atmospheric plasma discharge simulation

    Lange, Kyle J.; Anderson, W. Kyle

    2010-01-01

    The problem of applying sensitivity analysis to a one-dimensional atmospheric radio frequency plasma discharge simulation is considered. A fluid simulation is used to model an atmospheric pressure radio frequency helium discharge with a small nitrogen impurity. Sensitivity derivatives are computed for the peak electron density with respect to physical inputs to the simulation. These derivatives are verified using several different methods to compute sensitivity derivatives. It is then demonstrated how sensitivity derivatives can be used within a design cycle to change these physical inputs so as to increase the peak electron density. It is also shown how sensitivity analysis can be used in conjunction with experimental data to obtain better estimates for rate and transport parameters. Finally, it is described how sensitivity analysis could be used to compute an upper bound on the uncertainty for results from a simulation.

  12. A new approach to the evaluation of the discharge parameters of the electrodeless fluorescent lamps

    Statnic, Eugen; Tanach, Valentin

    2004-01-01

    A new model was developed for the characterization and quantification of the 'inaccessible' discharge parameters in closed tube high power electrodeless fluorescent lamps. The results obtained applying the model are verifiable by means of a simple comparison of the primary equivalent resistance and reactance as a result of the measured V 1 , I 1 , ψ 1 with the equivalent primary resistance and reactance inferred from the proposed model. The results are in good agreement at all operating lamp power levels. What is unexpected is the capacitive behaviour of the inductive coupled plasma at lower powers. The investigation method is suitable for the optimization of high power electrodeless lamps with a long discharge path operated at low frequencies, in order to improve the efficiency and the system stability, especially if the lamp has to be dimmed

  13. Influence of Wire Electrical Discharge Machining (WEDM) process parameters on surface roughness

    Yeakub Ali, Mohammad; Banu, Asfana; Abu Bakar, Mazilah

    2018-01-01

    In obtaining the best quality of engineering components, the quality of machined parts surface plays an important role. It improves the fatigue strength, wear resistance, and corrosion of workpiece. This paper investigates the effects of wire electrical discharge machining (WEDM) process parameters on surface roughness of stainless steel using distilled water as dielectric fluid and brass wire as tool electrode. The parameters selected are voltage open, wire speed, wire tension, voltage gap, and off time. Empirical model was developed for the estimation of surface roughness. The analysis revealed that off time has a major influence on surface roughness. The optimum machining parameters for minimum surface roughness were found to be at a 10 V open voltage, 2.84 μs off time, 12 m/min wire speed, 6.3 N wire tension, and 54.91 V voltage gap.

  14. Studies on pulsed hollow cathode capillary discharges

    Choi, P; Dumitrescu-Zoita, C; Larour, J; Rous, J [Ecole Polytechnique, 91 - Palaiseau (France). Lab. de Physique des Milieux Ionises; Favre, M; Moreno, J; Chuaqui, H; Wyndham, E [Pontificia Univ. Catolica de Chile, Santiago (Chile). Facultad de Fisica; Zambra, M [Comision Chilena de Energia Nuclear, Santiago (Chile); Wong, C S [Univ. of Malaya, Kuala Lumpur (Malaysia). Plasma Research Lab

    1997-12-31

    Preliminary results on radiation characteristics of pulsed hollow cathode capillary discharges are presented. The device combines the on axis electron beam assisted ionization capabilities of the transient hollow cathode discharge with a novel high voltage low inductance geometrical design, which integrates the local energy storage into the electrode system. A nanosecond regime high temperature plasma is produced in a long, high aspect ratio capillary, with light emission in the UV to XUV region. The discharge is operated from near vacuum to pressure in the 1000 mTorr range. (author). 2 figs., 7 refs.

  15. Optical characteristics and parameters of gas-discharge plasma in a mixture of mercury dibromide vapor with neon

    Malinina, A. A.; Malinin, A. N.

    2013-01-01

    Results are presented from studies of the optical characteristics and parameters of plasma of a dielectric barrier discharge in a mixture of mercury dibromide vapor with neon—the working medium of a non-coaxial exciplex gas-discharge emitter. The electron energy distribution function, the transport characteristics, the specific power losses for electron processes, the electron density and temperature, and the rate constants for the processes of elastic and inelastic electron scattering by the working mixture components are determined as functions of the reduced electric field. The rate constant of the process leading to the formation of exciplex mercury monobromide molecules is found to be 1.6 × 10 −14 m 3 /s for a reduced electric field of E/N = 15 Td, at which the maximum emission intensity in the blue-green spectral region (λ max = 502 nm) was observed in this experiment

  16. Optical characteristics and parameters of gas-discharge plasma in a mixture of mercury dibromide vapor with neon

    Malinina, A. A.; Malinin, A. N.

    2013-12-01

    Results are presented from studies of the optical characteristics and parameters of plasma of a dielectric barrier discharge in a mixture of mercury dibromide vapor with neon—the working medium of a non-coaxial exciplex gas-discharge emitter. The electron energy distribution function, the transport characteristics, the specific power losses for electron processes, the electron density and temperature, and the rate constants for the processes of elastic and inelastic electron scattering by the working mixture components are determined as functions of the reduced electric field. The rate constant of the process leading to the formation of exciplex mercury monobromide molecules is found to be 1.6 × 10-14 m3/s for a reduced electric field of E/ N = 15 Td, at which the maximum emission intensity in the blue-green spectral region (λmax = 502 nm) was observed in this experiment.

  17. Optical characteristics and parameters of gas-discharge plasma in a mixture of mercury dibromide vapor with neon

    Malinina, A. A., E-mail: alexandr_malinin@rambler.ru; Malinin, A. N. [Uzhhorod National University (Ukraine)

    2013-12-15

    Results are presented from studies of the optical characteristics and parameters of plasma of a dielectric barrier discharge in a mixture of mercury dibromide vapor with neon—the working medium of a non-coaxial exciplex gas-discharge emitter. The electron energy distribution function, the transport characteristics, the specific power losses for electron processes, the electron density and temperature, and the rate constants for the processes of elastic and inelastic electron scattering by the working mixture components are determined as functions of the reduced electric field. The rate constant of the process leading to the formation of exciplex mercury monobromide molecules is found to be 1.6 × 10{sup −14} m{sup 3}/s for a reduced electric field of E/N = 15 Td, at which the maximum emission intensity in the blue-green spectral region (λ{sub max} = 502 nm) was observed in this experiment.

  18. Estimation of parameters for the electrostatic discharge current equation with real human discharge events reference using genetic algorithms

    Katsivelis, P S; Gonos, I F; Stathopulos, I A

    2010-01-01

    Thorough study of the electrostatic discharge (ESD) current equation shows that it may be different from the equation proposed in the IEC 61000-4-2 Standard. This problem is dealt with in this paper. Using a 2.5 GHz digital oscilloscope and a 50 Ω Pellegrini target as the measuring system, and a dc power supply to provide a charging voltage of 2 kVdc, a series of measurements were performed, so real human-to-metal ESD current waveforms were recorded. Treating the average waveform as a reference, a genetic algorithm (GA) was applied to the equation of the IEC 61000-4-2 Standard for the ESD current, in order to achieve its best fitting to the data set. Four different error norms were used for the GA applications. The best result of the applications of each of them was saved and compared to the others. Thus, a very satisfactory modification of the Standard's equation is presented, which is closer to the real ESD current waveform

  19. Evaluating the electrical discharge machining (EDM) parameters with using carbon nanotubes

    Sari, M. M.; Noordin, M. Y.; Brusa, E.

    2012-09-01

    Electrical discharge machining (EDM) is one of the most accurate non traditional manufacturing processes available for creating tiny apertures, complex or simple shapes and geometries within parts and assemblies. Performance of the EDM process is usually evaluated in terms of surface roughness, existence of cracks, voids and recast layer on the surface of product, after machining. Unfortunately, the high heat generated on the electrically discharged material during the EDM process decreases the quality of products. Carbon nanotubes display unexpected strength and unique electrical and thermal properties. Multi-wall carbon nanotubes are therefore on purpose added to the dielectric used in the EDM process to improve its performance when machining the AISI H13 tool steel, by means of copper electrodes. Some EDM parameters such as material removal rate, electrode wear rate, surface roughness and recast layer are here first evaluated, then compared to the outcome of EDM performed without using nanotubes mixed to the dielectric. Independent variables investigated are pulse on time, peak current and interval time. Experimental evidences show that EDM process operated by mixing multi-wall carbon nanotubes within the dielectric looks more efficient, particularly if machining parameters are set at low pulse of energy.

  20. Evaluating the electrical discharge machining (EDM) parameters with using carbon nanotubes

    Sari, M M; Brusa, E; Noordin, M Y

    2012-01-01

    Electrical discharge machining (EDM) is one of the most accurate non traditional manufacturing processes available for creating tiny apertures, complex or simple shapes and geometries within parts and assemblies. Performance of the EDM process is usually evaluated in terms of surface roughness, existence of cracks, voids and recast layer on the surface of product, after machining. Unfortunately, the high heat generated on the electrically discharged material during the EDM process decreases the quality of products. Carbon nanotubes display unexpected strength and unique electrical and thermal properties. Multi-wall carbon nanotubes are therefore on purpose added to the dielectric used in the EDM process to improve its performance when machining the AISI H13 tool steel, by means of copper electrodes. Some EDM parameters such as material removal rate, electrode wear rate, surface roughness and recast layer are here first evaluated, then compared to the outcome of EDM performed without using nanotubes mixed to the dielectric. Independent variables investigated are pulse on time, peak current and interval time. Experimental evidences show that EDM process operated by mixing multi-wall carbon nanotubes within the dielectric looks more efficient, particularly if machining parameters are set at low pulse of energy.

  1. Overvoltage in chain of insulators front to lightning discharges: a comparative study of the calculation methods and of the parameter Z{sub t}; Sobretensoes em cadeia de isoladores frente a descargas atmosfericas: um estudo comparativo dos metodos de calculo e do parametro Z{sub t}

    Godoy, Antonio Varejao de

    1989-07-01

    This work studies in a deterministic point of view a lightning discharges that strikes directly the transmission line tower top. The calculation methods of this kind of surges: the method of successive reflections introduced by Jordan and the method of field well as compared with these purpose. Based on this two approaches a computational program is developed to calculate the overvoltage on the insulator string and the required parameters. Based on the results of this analysis, the simplest and most efficient method is chosen and where a simple sensitivity analysis is made for the following parameters: the impedance of lightning stroke channel, the tower foot impedance, time to crest of stroke shape function and tower surge impedance. This analysis is performed in order to verify the voltage variation on the insulator string. Finally, the last parameter, the tower surge impedance is emphasized comparing its calculated values with the measured values by geometrical model technique. (author)

  2. Parametric study of radiofrequency helium discharge under ...

    The excitation temperatures in the α and γ modes were 3266 and 4500 K respectively, evaluated by Boltzmann's plot method. The estimated gas temperature increased from 335 K in the α mode to 485 K in the γ mode, suggesting that the radio frequency atmospheric pressure helium discharge can be used for surface ...

  3. Influence of the fuel operational parameters on the aluminium cladding quality of discharged fuel

    Chwaszczewski, S.; Czajkowski, W.; Borek-Kruszewska, E. [Institute of Atomic Energy, Otwock Swierk (POLAND)

    2002-07-01

    In the last two years, the new MR6 type fuel containing 1550 g of U with 36% enrichment has been loaded into MARIA reactor core. Its aluminium cladding thickness is 0,6 mm and typical burnup -about 4080 MWh (as compared to 2880 MWh for the 80% enriched fuel used). However, increased fission product release from these assemblies was observed near the end of its operational time. The results presented earlier [1] show that the corrosion behaviour of aluminium cladding depends on the conditions of fuel operation in the reactor. The corrosion process in the aluminum of fuel cladding proceeds faster then in the aluminum of constructional elements. This tendency was also observed in MR-6/80% and in WWR- SM fuel assemblies. Therefore the visual tests of discharged MR-6/36% fuel elements were performed. Some change of appearance of aluminum cladding was observed, especially in the regions with large energy generation i.e. in the centre of reactor core and in the strong horizontal gradient of neutron flux. In the present paper, the results of visual investigation of discharged fuel assemblies are presented. The results of the investigation are correlated with the operational parameters. (author)

  4. Study of electric discharges between moving electrodes in air

    Andreev, V. V.; Pichugin, Yu. P.; Telegin, V. G.; Telegin, G. G.

    2011-01-01

    A barrier electric discharge excited between a fixed electrode and a rotating electrode covered with a dielectric layer in atmospheric-pressure air is studied experimentally. A distinctive feature of this type of discharge is that it operates at a constant voltage between the electrodes. An advantage of the proposed method for plasma generation in the boundary layer of the rotating electrode (e.g., for studying the influence of plasma on air flows) is the variety of forms of the discharge and conditions for its initiation, simplicity of the design of the discharge system, and ease of its practical implementation

  5. Study of electric discharges between moving electrodes in air

    Andreev, V. V.; Pichugin, Yu. P.; Telegin, V. G.; Telegin, G. G. [Chuvash State University (Russian Federation)

    2011-12-15

    A barrier electric discharge excited between a fixed electrode and a rotating electrode covered with a dielectric layer in atmospheric-pressure air is studied experimentally. A distinctive feature of this type of discharge is that it operates at a constant voltage between the electrodes. An advantage of the proposed method for plasma generation in the boundary layer of the rotating electrode (e.g., for studying the influence of plasma on air flows) is the variety of forms of the discharge and conditions for its initiation, simplicity of the design of the discharge system, and ease of its practical implementation.

  6. Recent results from studies of electric discharges in the mesosphere

    Neubert, Torsten; Rycroft, M.; Farges, T.

    2008-01-01

    The paper reviews recent advances in studies of electric discharges in the stratosphere and mesosphere above thunderstorms, and their effects on the atmosphere. The primary focus is on the sprite discharge occurring in the mesosphere, which is the most commonly observed high altitude discharge...... to 1000 km distance, whereas elves and lightning have been shown significantly to affect ionization and heating of the lower ionosphere/mesosphere. Studies of the thunderstorm systems powering high altitude discharges show the important role of intracloud (IC) lightning in sprite generation as seen...

  7. Study of glow discharge positive column with cloud of disperse particles

    Polyakov, D.N.; Shumova, V.V.; Vasilyak, L.M.; Fortov, V.E.

    2011-01-01

    The study aims to describe plasma parameters changes induced by clouds of disperse micron size particles. Dust clouds were formed in the positive column of glow discharge in air at pressure 0.1-0.6 torr and current 0.1-3 mA. The simultaneous registration of discharge voltage and dust cloud parameters was carried out. Experimental results were simulated using diffusion model. The dust cloud is shown to smooth the radial electron concentration profile, increase electric field strength and electron temperature and stabilize the discharge. The cloud is demonstrated to be a trap for positive ions without increase of discharge current. -- Highlights: → 25% increase of longitudinal electric field strength in discharge with dust cloud. → The smoothing effect of dust cloud on radial electron and ion concentration profiles. → Dust cloud as a trap for positive ions without increase of discharge current. → Increase of electron temperature in discharge with dust cloud. → Increase of discharge stability in presence of dust cloud.

  8. Numerical study on rectangular microhollow cathode discharge

    He Shoujie; Ouyang Jiting; He Feng; Li Shang

    2011-01-01

    Rectangular microhollow cathode discharge in argon is investigated by using two-dimensional time-dependent self-consistent fluid model. The electric potential, electric field, particle density, and mean electron energy are calculated. The results show that hollow cathode effect can be onset in the present configuration, with strong electric field and high mean electron energy in the cathode fall while high density and quasineutral plasma in the negative glow. The potential well and electric filed reversal are formed in the negative glow region. It is suggested that the presence of large electron diffusion flux necessitates the field reversal and potential well.

  9. Study of asymmetrical electric discharges using particle simulation

    Alves, M.V.

    1990-11-01

    Asymmetrical electric discharges are been widely used in the microelectronic industry. The asymmetry in the electrode areas determines the magnitude of the plasma-to-electrode voltage, V sub(a), at the powered electrode, which determines the ion bombarding energy, a critical plasma processing parameter. Two many-particle simulation codes, called P D C 1 and P D S 1, were developed. These codes are electrostatic, one-dimensional (radial) and model (a bounded plasma between two infinite cylinders or two concentric spheres that can be connected to a RLC external circuit. Both codes consider asymmetrical electrodes areas. In order to simulate electrical discharges, Monte-Carlo simulation of electron-neutral and ion-neutral collisions were included. These codes were used to study the relationship between the voltage area ratio across the sheaths, V sub(a) / V sub(b), and the electrode area ratio A sub(b) / A sub(a). Simulation results agree with experimental results and also with the analytical model that includes local ionization near the electrodes, observed to occur in almost all our simulations. (author)

  10. Influence of electrical resistivity and machining parameters on electrical discharge machining performance of engineering ceramics.

    Ji, Renjie; Liu, Yonghong; Diao, Ruiqiang; Xu, Chenchen; Li, Xiaopeng; Cai, Baoping; Zhang, Yanzhen

    2014-01-01

    Engineering ceramics have been widely used in modern industry for their excellent physical and mechanical properties, and they are difficult to machine owing to their high hardness and brittleness. Electrical discharge machining (EDM) is the appropriate process for machining engineering ceramics provided they are electrically conducting. However, the electrical resistivity of the popular engineering ceramics is higher, and there has been no research on the relationship between the EDM parameters and the electrical resistivity of the engineering ceramics. This paper investigates the effects of the electrical resistivity and EDM parameters such as tool polarity, pulse interval, and electrode material, on the ZnO/Al2O3 ceramic's EDM performance, in terms of the material removal rate (MRR), electrode wear ratio (EWR), and surface roughness (SR). The results show that the electrical resistivity and the EDM parameters have the great influence on the EDM performance. The ZnO/Al2O3 ceramic with the electrical resistivity up to 3410 Ω·cm can be effectively machined by EDM with the copper electrode, the negative tool polarity, and the shorter pulse interval. Under most machining conditions, the MRR increases, and the SR decreases with the decrease of electrical resistivity. Moreover, the tool polarity, and pulse interval affect the EWR, respectively, and the electrical resistivity and electrode material have a combined effect on the EWR. Furthermore, the EDM performance of ZnO/Al2O3 ceramic with the electrical resistivity higher than 687 Ω·cm is obviously different from that with the electrical resistivity lower than 687 Ω·cm, when the electrode material changes. The microstructure character analysis of the machined ZnO/Al2O3 ceramic surface shows that the ZnO/Al2O3 ceramic is removed by melting, evaporation and thermal spalling, and the material from the working fluid and the graphite electrode can transfer to the workpiece surface during electrical discharge

  11. Assessment of accidental refinery wastewater discharge: a case study

    Bandyopadhyay, Amitava [University of Calcutta, Department of Chemical Engineering, Kolkata (India)

    2011-04-15

    The physicochemical qualities of an accidental discharge of refinery liquid waste, water, and soil sediment of that effluent-receiving water body (canal) were investigated. Analyses of the discharge, qualities of water, and sediment of the canal showed high parametric concentrations. Investigations revealed that the discharge took place form the spent caustic that was generated from the caustic wash tower of Fluidized Catalytic Cracker of the refinery. A simple but realistic model was suggested for the remediation of sediments of the canal with an estimated cost of about US $1.86 million. Recommendations were made to prevent such discharges and to revise thoroughly the Indian effluent discharge standards in force for petroleum oil refinery. Subsequently, revised standards were notified under Indian guidelines. Interestingly, cyanide besides many other parameters was introduced into these standards. Furthermore, Volatile Organic Compound (VOC) was also stipulated as an emission parameter from the waste water treatment plants. Concentration- and mass-based standards thus promulgated were stricter than the existing standards. (orig.)

  12. Analysis of aspects of quality of life in teachers' voice after discharged: longitudinal study.

    Ferreira, Josiane Mendes; Campos, Nathália Ferreira; Bassi, Iara Barreto; Santos, Marco Aurélio Rocha; Teixeira, Letícia Caldas; Gama, Ana Cristina Côrtes

    2013-01-01

    To evaluate the long-term effects of voice therapy on the life quality of teachers who were discharged or abandoned the voice therapy for dysphonia. This was a longitudinal study based on analysis of assessments with teachers of municipal schools in Belo Horizonte, who were referred to voice therapy and were discharged or abandoned the speech-language therapy for more than six months. A total of 33 teachers in the discharged group and 20 teachers in the abandoned group were contacted by phone and invited to participate in the study by answering the Voice activity and participation profile, which was forwarded to the researchers and sent via letter. At the moment of the pre speech therapy, the discharged and abandoned groups were homogeneous, except in relation to daily communication parameter. Comparing the discharged group in the pre and post speech-language therapy, it was showed improvements in social communication parameter as well as in the total score. The discharged group presented worsening in self-perception parameter when comparing the average values in the post therapy and current moments, and the group abandoned presented worsening in work, social communication and total score when comparing to the average values in the pre therapy and current moments. The discharged and abandoned groups differ in the present moment in all investigated parameters. Speech-language therapy for dysphonia have long term positive effects on life quality and voice of teachers who were soon discharged from the therapy and in a period of two years on average. Teachers who have abandoned treatment and did not obtain improvement in the voice showed negative impact in life quality and voice in a time of 2 years and 2 months on average.

  13. Influence of air flow parameters on nanosecond repetitively pulsed discharges in a pin-annular electrode configuration

    Heitz, Sylvain A; Moeck, Jonas P; Schuller, Thierry; Veynante, Denis; Lacoste, Deanna

    2016-01-01

    The effect of various air flow parameters on the plasma regimes of nanosecond repetitively pulsed (NRP) discharges is investigated at atmospheric pressure. The two electrodes are in a pin-annular configuration, transverse to the mean flow. The voltage pulses have amplitudes up to 15 kV, a duration of 10 ns and a repetition frequency ranging from 15 to 30 kHz. The NRP corona to NRP spark (C-S) regime transition and the NRP spark to NRP corona (S-C) regime transition are investigated for different steady and harmonically oscillating flows. First, the strong effect of a transverse flow on the C-S and S-C transitions, as reported in previous studies, is verified. Second, it is shown that the azimuthal flow imparted by a swirler does not affect the regime transition voltages. Finally, the influence of low frequency harmonic oscillations of the air flow, generated by a loudspeaker, is studied. A strong effect of frequency and amplitude of the incoming flow modulation on the NRP plasma regime is observed. Results are interpreted based on the cumulative effect of the NRP discharges and an analysis of the residence times of fluid particles in the inter-electrode region. © 2016 IOP Publishing Ltd.

  14. Influence of air flow parameters on nanosecond repetitively pulsed discharges in a pin-annular electrode configuration

    Heitz, Sylvain A

    2016-03-16

    The effect of various air flow parameters on the plasma regimes of nanosecond repetitively pulsed (NRP) discharges is investigated at atmospheric pressure. The two electrodes are in a pin-annular configuration, transverse to the mean flow. The voltage pulses have amplitudes up to 15 kV, a duration of 10 ns and a repetition frequency ranging from 15 to 30 kHz. The NRP corona to NRP spark (C-S) regime transition and the NRP spark to NRP corona (S-C) regime transition are investigated for different steady and harmonically oscillating flows. First, the strong effect of a transverse flow on the C-S and S-C transitions, as reported in previous studies, is verified. Second, it is shown that the azimuthal flow imparted by a swirler does not affect the regime transition voltages. Finally, the influence of low frequency harmonic oscillations of the air flow, generated by a loudspeaker, is studied. A strong effect of frequency and amplitude of the incoming flow modulation on the NRP plasma regime is observed. Results are interpreted based on the cumulative effect of the NRP discharges and an analysis of the residence times of fluid particles in the inter-electrode region. © 2016 IOP Publishing Ltd.

  15. Mercury-free electrodeless discharge lamp: effect of xenon pressure and plasma parameters on luminance

    Nazri Dagang Ahmad; Kondo, Akira; Motomura, Hideki; Jinno, Masafumi

    2009-01-01

    Since there is much concern about environmental preservation, the authors have paid attention to the uses of mercury in lighting application. They have focused on the application of the xenon low-pressure inductively coupled plasma (ICP) discharge in developing cylindrical type mercury-free light sources. ICP can be operated at low filling gas pressures and demonstrates significant potential in producing high density plasma. Xenon pressure was varied from 0.1 to 100 Torr and the lamp luminance was measured. The gas pressure dependence shows an increase in luminance at pressures below 1 Torr. In order to clarify this behaviour, measurement of plasma parameters was carried out using the double probe method and its relation to lamp luminance is discussed. As the gas pressure is decreased (from 1 to 0.01 Torr), the electron temperature increases while the electron density decreases while at the same time the lamp luminance increases. There are several factors that are believed to contribute to the increase in luminance in the very low pressure region. Increases in luminance are considered to be due to the electron-ion recombination process which brings a strong recombination radiation in continuum in the visible region and also due to the effect of stochastic heating.

  16. V-I curves and plasma parameters in a high density DC glow discharge generated by a current-source

    Granda-Gutierrez, E E; Lopez-Callejas, R; Piedad-Beneitez, A de la; BenItez-Read, J S; Pacheco-Sotelo, J O; Pena-Eguiluz, R; A, R Valencia; Mercado-Cabrera, A; Barocio, S R

    2008-01-01

    Nitrogen DC glow discharges, conducted in a cylindrical geometry, have been characterized using a new current-source able to provide 10 -3 - 3 A for the sustainment of the discharge, instead of a conventional voltage-source. The V-I characteristic curves obtained from these discharges were found to fit the general form i(v) = A(p)v k(p) , whereby the plasma itself can be modeled as a voltage-controlled current-source. We conclude that the fitting parameters A and k, which mainly depend on the gas pressure p, are strongly related to the plasma characteristics, so much so that they can indicate the pressure interval in which the maximum plasma density is located, with values in the order of 10 16 m -3 at reduced discharge potential (300-600 V) and low working pressure (10 -1 - 10 1 Pa)

  17. Optical characteristics and parameters of gas-discharge plasma in a mixture of mercury dibromide vapor with argon

    Malinina, A. A.; Malinin, A. N.

    2015-03-01

    Results are presented from studies of the optical characteristics and parameters of the plasma of a dielectric barrier discharge in a mixture of mercury dibromide vapor with argon—the working medium of an exciplex gas-discharge emitter. It is established that the partial pressures of mercury dibromide vapor and argon at which the average and pulsed emission intensities in the blue—green spectral region (λmax = 502 nm) reach their maximum values are 0.6 and 114.4 kPa, respectively. The electron energy distribution function, the transport characteristics, the specific power spent on the processes involving electrons, the electron density and temperature, and the rate constants for the processes of elastic and inelastic electron scattering from the molecules and atoms of the working mixture are determined by numerical simulation, and their dependences on the reduced electric field strength are analyzed. The rate constant of the process leading to the formation of exciplex mercury monobromide molecules for a reduced electric field of E/ N = 20 Td, at which the maximum emission intensity in the blue—green spectral region was observed in this experiment, is found to be 8.1 × 10-15 m3/s.

  18. Optical characteristics and parameters of gas-discharge plasma in a mixture of mercury dibromide vapor with argon

    Malinina, A. A., E-mail: alexandr-malinin@rambler.ru; Malinin, A. N. [Uzhhorod National University (Ukraine)

    2015-03-15

    Results are presented from studies of the optical characteristics and parameters of the plasma of a dielectric barrier discharge in a mixture of mercury dibromide vapor with argon—the working medium of an exciplex gas-discharge emitter. It is established that the partial pressures of mercury dibromide vapor and argon at which the average and pulsed emission intensities in the blue—green spectral region (λ{sub max} = 502 nm) reach their maximum values are 0.6 and 114.4 kPa, respectively. The electron energy distribution function, the transport characteristics, the specific power spent on the processes involving electrons, the electron density and temperature, and the rate constants for the processes of elastic and inelastic electron scattering from the molecules and atoms of the working mixture are determined by numerical simulation, and their dependences on the reduced electric field strength are analyzed. The rate constant of the process leading to the formation of exciplex mercury monobromide molecules for a reduced electric field of E/N = 20 Td, at which the maximum emission intensity in the blue—green spectral region was observed in this experiment, is found to be 8.1 × 10{sup −15} m{sup 3}/s.

  19. Optical characteristics and parameters of gas-discharge plasma in a mixture of mercury dibromide vapor with argon

    Malinina, A. A.; Malinin, A. N.

    2015-01-01

    Results are presented from studies of the optical characteristics and parameters of the plasma of a dielectric barrier discharge in a mixture of mercury dibromide vapor with argon—the working medium of an exciplex gas-discharge emitter. It is established that the partial pressures of mercury dibromide vapor and argon at which the average and pulsed emission intensities in the blue—green spectral region (λ max = 502 nm) reach their maximum values are 0.6 and 114.4 kPa, respectively. The electron energy distribution function, the transport characteristics, the specific power spent on the processes involving electrons, the electron density and temperature, and the rate constants for the processes of elastic and inelastic electron scattering from the molecules and atoms of the working mixture are determined by numerical simulation, and their dependences on the reduced electric field strength are analyzed. The rate constant of the process leading to the formation of exciplex mercury monobromide molecules for a reduced electric field of E/N = 20 Td, at which the maximum emission intensity in the blue—green spectral region was observed in this experiment, is found to be 8.1 × 10 −15 m 3 /s

  20. Yield of Ozone, Nitrite Nitrogen and Hydrogen Peroxide Versus Discharge Parameter Using APPJ Under Water

    Chen Bingyan; Wen Wen; Zhu Changping; Wang Yuan; Gao Ying; Fei Juntao; He Xiang; Yin Cheng; Jiang Yongfeng; Chen Longwei

    2016-01-01

    Discharge plasma in and in contact with water can be accompanied with ultraviolet radiation and electron impact, thus can generate hydroxyl radicals, ozone, nitrite nitrogen and hydrogen peroxide. In this paper, a non-equilibrium plasma processing system was established by means of an atmospheric pressure plasma jet immersed in water. The hydroxyl intensities and discharge energy waveforms were tested. The results show that the positive and negative discharge energy peaks were asymmetric, where the positive discharge energy peak was greater than the negative one. Meanwhile, the yield of ozone and nitrite nitrogen was enhanced with the increase of both the treatment time and the discharge energy. Moreover, the pH value of treated water was reduced rapidly and maintained at a lower level. The residual concentration of hydrogen peroxide in APPJ treated water was kept at a low level. Additionally, both the efficiency energy ratio of the yield of ozone and nitrite nitrogen and that of the removal of p-nitrophenol increased as a function of discharge energy and discharge voltage. The experimental results were fully analyzed and the chemical reaction equations and the physical processes of discharges in water were given. (paper)

  1. Contribution to the study of 'Pseudo-spark' discharges applied to the realisation of latch devices

    Bauville, Gerard

    1994-01-01

    The objective of this research thesis is to study discharges growing from a hollow geometry of electrodes for pressures on the left side of the Paschen minimum. The study characterises the main conduction phase by experimentally determining the discharge voltage and current. Based on a numerical analysis, the author deduces some macroscopic characteristics such as voltage mean value, dissipated energy, with respect to the variation of various parameters such as gas pressure and nature, discharge duration, and electrode cavity geometries. After a first part on switches (technological applications, switches, pseudo-spark breakers), the author addresses the discharges (presentation of a 'pseudo-spark'-type discharge, involved physical mechanisms, methods of initiation of pseudo-spark discharges, triggering by a magnetic field pulse). The next part describes the test bench in a detailed way (electrodes, triggering system, electric configurations), and the last part reports the experimental study. It addresses the following issues: distribution of magnetic field lines, voltage drop, conjunction phase, discharge footprints on the surfaces, propagation rate, disjunction [fr

  2. Spectroscopic Study of Electrical Glow Discharges in Gases

    Reyes, P. G.; Evangelista, M.; Trujillo, C.; Castillo, F.; Rangel, J.

    2006-12-01

    The variation of the power of the light emitted in a Glow Discharge in Gases of low pressure (GDGLP) excited by a DC source was studied. A lack of dependency of the kind of gas used and the pressure it is located at was obtained. This is comparable to the potential drop which takes place in the discharge by inelastic collisions such as ionization, recombination, excitation, relaxation, etc.

  3. Studies on the Electrical Characteristics of a DC Glow Discharge by Using Langmuir Probe

    Safaai, S. S.; Yap, S. L.; Wong, C. S.; Muniandy, S. V.; Smith, P. W.

    2010-01-01

    Electrical characteristics of a DC glow discharge are studied with the aim of determining the suitable parameters for stable operation of the dusty plasma system. The presence of dust particles in plasma significantly alters the charged particle equilibrium in the plasma and leads to various phenomena. Argon plasma produced by DC glow discharge is investigated with a further goal of studying dusty plasma phenomena. The discharge system has two disc-shaped parallel plate electrodes. The electrodes are enclosed in a large cylindrical stainless steel chamber filled with argon gas. Two important physical parameters affecting the condition of the discharge are the gas pressure and the inter-electrode distance. A single Langmuir probe based on the Keithley source meter is used to determine the electron temperature of the positive column. A custom designed probe is employed to determine the potential distribution between the electrodes during the discharge. The I-V characteristic curve and the Langmuir probe measurement are then used to determine the electron energy distribution of the glow discharge plasma.

  4. Study of discharge in quiescent plasma machine of the INPE

    Ferreira, J.G.; Ferreira, J.L.; Ludwig, G.O.; Maciel, H.S.

    1988-12-01

    Measurements of principal plasma parameters produced by quiescent plasma machine of the Instituto de Pesquisas Espaciais (INPE) for current of 500 mA and several values of pressure and discharge power are presented. A qualitative interpretation for obtained results is done and a simple model for plasma density is compared with experimental values. The conditions of cathode operation are also investigated. (M.C.K.)

  5. A descriptive study of urethral discharge among men in Fiji.

    Gaunavinaka, Lavenia; Balak, Dashika; Varman, Sumanthla; Ram, Sharan; Graham, Stephen M

    2014-10-17

    Urethral discharge is a common presentation of sexually transmitted infection (STI) in men and known pathogens include Neisseria gonorrhoeae and Chlamydia trachomatis. There are no published data of the burden of urethral discharge among men in Fiji. To evaluate urethral discharge among men to determine the incidence, the frequency of recurrence and reported at-risk behaviour. We conducted a retrospective, descriptive study of clinical records of all men presenting with urethral discharge to two major reproductive health clinics. Data collected included self-reported at-risk behaviours, results of abnormal syphilis serology and antibiotics prescribed. The frequency of recurrence in the following 1-2 years of initial presentation was determined along with microbiological findings from urethral swab in this group. A total of 748 males presented with urethral discharge to the clinic in one year. This represents an incidence rate of at least 295 per 100,000 adult males per year in the study population. Within the next 1-2 years of the initial presentation, 102 (14%) of these re-presented out of which 42 had urethral swab taken for etiological diagnosis. The commonest isolate was Neisseria gonorrhoeae. Results of syphilis tests were available for 560 (75%) of patients and 29 (5%) were positive. Recurrence was not associated with self-reported at-risk behaviours. The incidence of urethral discharge among males in Fiji is very high and prevention strategies are urgently needed.

  6. Numerical study on the discharge characteristics and nonlinear behaviors of atmospheric pressure coaxial electrode dielectric barrier discharges

    Zhang Ding-Zong; Wang Yan-Hui; Wang De-Zhen

    2017-01-01

    The discharge characteristics and temporal nonlinear behaviors of the atmospheric pressure coaxial electrode dielectric barrier discharges are studied by using a one-dimensional fluid model. It is shown that the discharge is always asymmetrical between the positive pulses and negative pulses. The gas gap severely affects this asymmetry. But it is hard to acquire a symmetrical discharge by changing the gas gap. This asymmetry is proportional to the asymmetric extent of electrode structure, namely the ratio of the outer electrode radius to the inner electrode radius. When this ratio is close to unity, a symmetrical discharge can be obtained. With the increase of frequency, the discharge can exhibit a series of nonlinear behaviors such as period-doubling bifurcation, secondary bifurcation and chaotic phenomena. In the period-doubling bifurcation sequence the period- n discharge becomes more and more unstable with the increase of n . The period-doubling bifurcation can also be obtained by altering the discharge gas gap. The mechanisms of two bifurcations are further studied. It is found that the residual quasineutral plasma from the previous discharges and corresponding electric field distribution can weaken the subsequent discharge, and leads to the occurrence of bifurcation. (paper)

  7. Interdependency between mechanical parameters and afferent nerve discharge in remodeled diabetic Goto-Kakizaki rat intestine.

    Zhao, Jingbo; Yang, Jian; Liao, Donghua; Gregersen, Hans

    2017-01-01

    Gastrointestinal disorders are very common in diabetic patients, but the pathogenesis is still not well understood. Peripheral afferent nerves may be involved due to the complex regulation of gastrointestinal function by the enteric nervous system. We aimed to characterize the stimulus-response function of afferent fibers innervating the jejunum in the Goto-Kakizaki (GK) type 2 diabetic rat model. A key question is whether changes in afferent firing arise from remodeled tissue or from adaptive afferent processes. Seven 32-week-old male GK rats and seven age-matched normal Wistar rats were studied. Firing from mesenteric afferent nerves was recorded in excised jejunal segments of seven GK rats and seven normal Wistar rats during ramp test, stress relaxation test, and creep test. The circumferential stress-strain, spike rate increase ratio (SRIR), and single unit firing rates were calculated for evaluation of interdependency of the mechanical stimulations and the afferent nerve discharge. Elevated sensitivity to mechanical stimuli was found for diabetic nerve bundles and single unit activity ( P <0.05). The stress relaxed less in the diabetic intestinal segment ( P <0.05). Linear association between SRIR and the thickness of circumferential muscle layer was found at high stress levels as well as for SRIR and the glucose level. Altered viscoelastic properties and elevated mechanosensitivity were found in the GK rat intestine. The altered nerve signaling is related to muscle layer remodeling and glucose levels and may contribute to gastrointestinal symptoms experienced by diabetic patients.

  8. Parameters of thunderstorm activity and lightning discharges in Central Yakutia from 2009 to 2012

    Kozlov, V. I.; Mullayarov, V. A.; Grigorev, Yu. M.; Tarabukina, L. D.

    2014-05-01

    The results of integrated instrumental observations of thunderstorm activity around Yakutsk at a radius of 400 and 30 km are presented. The seasonal course of thunderstorm activity was found to contain characteristic peaks in the first 10 days of June and the last 10 days of July or early August. The fraction of cloud-to-ground discharges in Central Yakutia is 40-60%, which is consistent with observations in Western Siberia (40-50%). The number of positive discharges to the ground was 8-15% of all cases of discharges to the ground, which is consistent with observations in Germany (17%) and slightly exceeds the observed number in the Caucasus (2.2-8.2%) and United States (4.5%). The thunderstorm activity in Yakutsk is three times higher than in the area around Yakutsk with a radius of 400 km, which can be explained by the fact that the city is a heat island.

  9. California study compares natural/drilling discharge contaminants offshore

    Steinhauer, W.G.; Imamura, E.; Barminski, J.R.; Neff, J.M.

    1992-01-01

    An analysis of drilling fluid and this paper reports that cuttings discharges in the southern Santa Maria basin offshore California indicates that the amount of metal and hydrocarbon contaminants from drilling operations is small relative to that from natural sources. The metal and hydrocarbon discharges were calculated for only one of the three platforms discharging between 1986 and 1989 in the Point Arguello field. However, assuming concentrations are similar on each platform, the combined input of metals and hydrocarbons over the 3-year period was still low (except for barium and lead) compared to the average annual flux from natural sources. The MMS is monitoring the Santa Maria basin to understand possible long-term environmental effects of oil and gas development (California Monitoring Program, Phase II; and Effects of OCS Production Platforms on Rocky Reef Fishes and Fisheries). A site-specific study area was established to determine effects of drilling-related discharges at Chevron U.S.S. Inc.'s platform Hidalgo in the Point Arguello field. Part of the study included review of discharge records for platforms Hidalgo, Hermosa (Chevron), and Harvest (Texaco Exploration and Production Inc.)

  10. Study of Heating and Fusion Power Production in ITER Discharges

    Rafiq, T.; Kritz, A. H.; Bateman, G.; Kessel, C.; McCune, D. C.; Budny, R. V.; Pankin, A. Y.

    2011-01-01

    ITER simulations, in which the temperatures, toroidal angular frequency and currents are evolved, are carried out using the PTRANSP code starting with initial profiles and boundary conditions obtained from TSC code studies. The dependence of heat deposition and current drive on ICRF frequency, number of poloidal modes, beam orientation, number of Monte Carlo particles and ECRH launch angles is studied in order to examine various possibilities and contingencies for ITER steady state and hybrid discharges. For the hybrid discharges, the fusion power production and fusion Q, computed using the Multi-Mode MMM v7.1 anomalous transport model, are compared with those predicted using the GLF23 model. The simulations of the hybrid scenario indicate that the fusion power production at 1000 sec will be approximately 500 MW corresponding to a fusion Q = 10.0. The discharge scenarios simulated aid in understanding the conditions for optimizing fusion power production and in examining measures of plasma performance.

  11. Interdependency between mechanical parameters and afferent nerve discharge in remodeled diabetic Goto-Kakizaki rat intestine

    Zhao J

    2017-12-01

    Full Text Available Jingbo Zhao,1 Jian Yang,1 Donghua Liao,1 Hans Gregersen2 1Giome Academia, Department of Clinical Medicine, Aarhus University, Aarhus, Denmark; 2Giome Center, Department of Surgery, Chinese University of Hong Kong and Prince of Wales Hospital, Shatin, Hong Kong Background: Gastrointestinal disorders are very common in diabetic patients, but the pathogenesis is still not well understood. Peripheral afferent nerves may be involved due to the complex regulation of gastrointestinal function by the enteric nervous system. Objective: We aimed to characterize the stimulus–response function of afferent fibers innervating the jejunum in the Goto-Kakizaki (GK type 2 diabetic rat model. A key question is whether changes in afferent firing arise from remodeled tissue or from adaptive afferent processes. Design: Seven 32-week-old male GK rats and seven age-matched normal Wistar rats were studied. Firing from mesenteric afferent nerves was recorded in excised jejunal segments of seven GK rats and seven normal Wistar rats during ramp test, stress relaxation test, and creep test. The circumferential stress–strain, spike rate increase ratio (SRIR, and single unit firing rates were calculated for evaluation of interdependency of the mechanical stimulations and the afferent nerve discharge. Results: Elevated sensitivity to mechanical stimuli was found for diabetic nerve bundles and single unit activity (P<0.05. The stress relaxed less in the diabetic intestinal segment (P<0.05. Linear association between SRIR and the thickness of circumferential muscle layer was found at high stress levels as well as for SRIR and the glucose level. Conclusion: Altered viscoelastic properties and elevated mechanosensitivity were found in the GK rat intestine. The altered nerve signaling is related to muscle layer remodeling and glucose levels and may contribute to gastrointestinal symptoms experienced by diabetic patients. Keywords: afferents, spike rate, stress–strain, creep

  12. Basic study for gas cleaning using discharge and electrophoresis

    Su, Zhen-Zhou; Sawada, Jun; Takashima, Kazunori; Katsura, Shinji; Mizuno, Akira

    2004-01-01

    A NO x removal method using discharge plasma and electrophoresis for exhaust control was studied. The 65-50% of NO was oxidized to NO 2 or HNO 3 by the discharge plasma with specific input energy of 45J/l. The electrophoresis was carried out to concentrate the NO 2 or HNO 3 adsorbed on the adsorbents. As a result, 80% of the adsorbed nitrate ions were found in the anode region. A combination of molecular sieve pellets of 13X and glass fiber cloth was tested for the collection of nitrate ions. The ability of simultaneous concentration of nitrate ions and sulfate ions using electrophoresis was examined

  13. Study on a negative hydrogen ion source with hot cathode arc discharge.

    Lin, S H; Fang, X; Zhang, H J; Qian, C; Ma, B H; Wang, H; Li, X X; Zhang, X Z; Sun, L T; Zhang, Z M; Yuan, P; Zhao, H W

    2014-02-01

    A negative hydrogen (H(-)) ion source with hot cathode arc discharge was designed and fabricated as a primary injector for a 10 MeV PET cyclotron at IMP. 1 mA dc H(-) beam with ɛ N, RMS = 0.08 π mm mrad was extracted at 25 kV. Halbach hexapole was adopted to confine the plasma. The state of arc discharge, the parameters including filament current, arc current, gas pressure, plasma electrode bias, and the ratio of I(e(-))/I(H(-)) were experimentally studied. The discussion on the result, and opinions to improve the source were given.

  14. Investigation of the time evolution of plasma parameters in a pulsed magnetron discharge

    Straňák, V.; Hubička, Zdeněk; Adámek, P.; Blažek, J.; Tichý, M.; Špatenka, P.; Hippler, R.; Wrehde, S.

    2006-01-01

    Roč. 56, - (2006), s. 1364-1370 ISSN 0011-4626 R&D Projects: GA ČR GA202/05/2242; GA ČR GA202/06/0776 Grant - others:Deutsche Forschungsgemeinschaft(DE) SFB/TR 24 Institutional research plan: CEZ:AV0Z10100522 Keywords : pulsed magnetron * time resolved measurements * Langmuir probe Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 0.568, year: 2006

  15. Improving the GIS-DRP Approach by Means of DelineatingRunoff Characteristics with New Discharge Relevant Parameters

    Marco Hümann

    2013-01-01

    Full Text Available At present it is common to use geographic information system (GIS applications to assess runoff generation. One of these GIS-based tools to generate maps of dominant runoff processes is the so called GIS-DRP approach. The tool, which has been developed mainly based on agricultural areas, uses commonly available input data like a digital elevation model (DEM, geological information as well as land use information. The aim of this study is to test, validate and improve this GIS-DRP method for forested and silviculture areas. Hence, soil-hydrologic investigations and several mapping techniques of dominant runoff processes were conducted on 25 test-plots in four forested catchments in Rhineland-Palatinate (Germany and the Grand Duchy of Luxembourg. By comparing the results of the mapping techniques and those of the test plots, weak points in the original GIS-DRP method were detected. Subsequently, it was possible to enhance the GIS-DRP approach by incorporating new discharge relevant parameters like topsoil sealing, extreme weather events and semipermeability of the substratum. Moreover, the improved GIS-DRP approach can be widely used in different landscapes and for different fields of application. The adapted method can now support foresters and decision makers in forestry planning, answer questions concerning the landscape water balance and peripheral water retention or provide extra information for sustainable forest planning in times of a changing climate.

  16. A Model Parameter Extraction Method for Dielectric Barrier Discharge Ozone Chamber using Differential Evolution

    Amjad, M.; Salam, Z.; Ishaque, K.

    2014-04-01

    In order to design an efficient resonant power supply for ozone gas generator, it is necessary to accurately determine the parameters of the ozone chamber. In the conventional method, the information from Lissajous plot is used to estimate the values of these parameters. However, the experimental setup for this purpose can only predict the parameters at one operating frequency and there is no guarantee that it results in the highest ozone gas yield. This paper proposes a new approach to determine the parameters using a search and optimization technique known as Differential Evolution (DE). The desired objective function of DE is set at the resonance condition and the chamber parameter values can be searched regardless of experimental constraints. The chamber parameters obtained from the DE technique are validated by experiment.

  17. Comet Halley, parameter study I

    Huebner, W.F.; Fikani, M.M.

    1982-06-01

    To aid in defining a mission to comet P/Halley, its inner coma is simulated by a computer program that models time-dependent chemical reactions in a radially and isentropically expanding gas, taking into account attenuation of solar ultraviolet radiation in the subsolar direction. Column density predictions are based on intelligently selected combinations of poorly known values for nucleus parameters that include size, visual albedo, and infrared emissivity. Only one chemical composition and a minor modification of it are considered here; the dust-to-gas ratio in this model is zero. Although the somewhat optimistically volatile composition chosen here favors a smaller nucleus, a mean nuclear radius of only 0.5 km is unlikely. No significant increase of molecular column density is predicted by this model as a spacecraft approaches, once it is less than a few 10 4 km from the nucleus. Predictions are made for various heliocentric distances of interest for comet missions and for ground observations

  18. Study of the metastable singlet of molecular nitrogen and of oxygen atoms in discharges and post-discharges

    Magne, Lionel

    1991-01-01

    Whereas discharges in nitrogen, in oxygen and in their mixtures are used in many different industrial processes (surface treatment, nitridation, oxidation, and so on), in order to get a better knowledge on nitrogen electronic states, this research thesis reports the study of the metastable singlet state of molecular nitrogen, and of oxygen atoms in their fundamental state. The molecular metastable has been observed by far-UV optical emission spectroscopy, in the positive column of a continuous discharge and in time post-discharge. As far as continuous discharge is concerned, the author measured the vibrational distribution of this state. A kinetic model has been developed, and calculated vibrational distributions are in good agreement with measurements. The density of oxygen atoms in fundamental state in time post-discharge has been measured by far-UV absorption optical spectroscopy. The probability of atom re-association of glass walls is deduced from the obtained results [fr

  19. Optical characteristics and parameters of the plasma of a barrier discharge excited in a mixture of mercury dibromide vapor with nitrogen and helium

    Malinina, A. A.; Guivan, N. N.; Shimon, L. L.; Shuaibov, A. K.

    2010-09-01

    Results are presented from experimental and theoretical studies of the optical characteristics and parameters of the plasma of an atmospheric-pressure barrier discharge excited in a HgBr2: N2: He mixture, which was used as the working medium of a small-size (with a radiation area of 8 cm2) exciplex gas-discharge radiation source. The mean radiation power of 87 mW was achieved at the radiation wavelength λmax = 502 nm. The electron energy distribution function, the transport characteristics, the specific energy lost in the processes involving electrons, the electron temperature and density, and the rate constants of elastic and inelastic electron scattering by the components of the working mixture were calculated as functions of the reduced field E/ N. The plasma of a discharge excited in a HgBr2: N2: He mixture can be used as the working medium of a small-size blue-green radiation source. Such a source can find application in biotechnology, photonics, and medicine and can also be used to manufacture gas-discharge display panels.

  20. Determination of discharge parameters via OES at the Linac4 H− ion source

    Briefi, S.; Fink, D.; Mattei, S.; Lettry, J.; Fantz, U.

    2016-01-01

    Optical emission spectroscopy (OES) measurements of the atomic Balmer series and the molecular Fulcher transition have been carried out at the Linac4 ion source in order to determine plasma parameters. As the spectroscopic system was only relatively calibrated, the data evaluation only yielded rough estimates of the plasma parameters (T e ≈ 1.2 eV, n e ≈ 1 × 10 19 m −3 , and n H /n H 2 ≈ 0.5 at standard operational parameters). The analysis of the Fulcher transition revealed a non-thermal “hockey-stick” rotational population of the hydrogen molecules. At varying RF power, the measurements at the on-axis line of sight (LOS) showed a peak in the rotational temperatures between 25 and 40 kW of RF power, whereas a steady decrease with power was observed at a tilted LOS, indicating the presence of strong plasma parameter gradients

  1. Plasma parameters in the vicinity of the quartz window of a low pressure surface wave discharge produced in O2

    Nakao, S.; Stamate, Eugen; Sugai, H.

    2007-01-01

    Plasma parameters in the vicinity of the dielectric window of a low density, microwave discharge produced in 0, at 915 N/FHz are investigated by a spherical probe and optical emission spectroscopy while the microwave field distribution is measured by a spectrum analyzer. The electron energy...... distribution function is found to be strongly dependent on the position with respect to the slot antenna, exhibiting a group of energetic electrons at locations where the electric field and the optical intensity exhibit maximum values. The density of energetic electrons decreases sharply just a few cm away...

  2. Optical and EUV studies of laser triggered Z-pinch discharges

    Tobin, Isaac

    2014-01-01

    This thesis describes the results of experiments with two geometries of laser assisted discharge plasma. Both devices are designed for fast Z-pinch discharge, triggered by laser produced plasma generated by ablation of one or both electrodes. The laser plasma parameters are adjusted to control the plasma load while the discharge parameters are adjusted to yield a rate of rise of current greater than 1010 A/s. The expansion dynamics and emission characteristics of the plasma were analysed, wit...

  3. A Parameter Study of Localization

    Sandor Stephen Mester

    1996-01-01

    Full Text Available Extensive work has been done on the vibration characteristics of perfectly periodic structures. Disorder in the periodic pattern has been found to lead to localization in one-dimensional periodic structures. It is important to understand localization because it causes energy to be concentrated near the disorder and may cause an overestimation of structural damping. A numerical study is conducted to obtain a better understanding of localization. It is found that any mode, even the first, can localize due to the presence of small imperfections.

  4. Determination of discharge parameters via OES at the Linac4 H{sup −} ion source

    Briefi, S., E-mail: stefan.briefi@physik.uni-augsburg.de [AG Experimentelle Plasmaphysik, Institut für Physik, Universität Augsburg, 86135 Augsburg (Germany); Fink, D.; Mattei, S.; Lettry, J. [Linac4 Ion Source Team, CERN-ABP, 1211 Geneva 23 (Switzerland); Fantz, U. [AG Experimentelle Plasmaphysik, Institut für Physik, Universität Augsburg, 86135 Augsburg (Germany); Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany)

    2016-02-15

    Optical emission spectroscopy (OES) measurements of the atomic Balmer series and the molecular Fulcher transition have been carried out at the Linac4 ion source in order to determine plasma parameters. As the spectroscopic system was only relatively calibrated, the data evaluation only yielded rough estimates of the plasma parameters (T{sub e} ≈ 1.2 eV, n{sub e} ≈ 1 × 10{sup 19} m{sup −3}, and n{sub H}/n{sub H{sub 2}} ≈ 0.5 at standard operational parameters). The analysis of the Fulcher transition revealed a non-thermal “hockey-stick” rotational population of the hydrogen molecules. At varying RF power, the measurements at the on-axis line of sight (LOS) showed a peak in the rotational temperatures between 25 and 40 kW of RF power, whereas a steady decrease with power was observed at a tilted LOS, indicating the presence of strong plasma parameter gradients.

  5. A DESCRIPTIVE STUDY OF FUNGAL INFECTIONS IN CHRONICALLY DISCHARGING EARS

    Sujatha

    2015-08-01

    Full Text Available BACKGROUND : Chronic Suppurative Otitis Media (CSOM is a disease of multiple aetiology and well known for its persis tence and recurrence inspite of treatment and are the bearbug of otologist, paediatrician and general practitioner. One of the reason s for the refractoriness to treatment and chronicity is coexist ing fungal infection of the ear. OBJECTIVES: Are to find out the prevalence of fungal infections in chronic discharging ears and to identify and isolate the type of fungus prevalent in these ears . MATERIALS AND METHOD S: Tertiary care hospital level descrip tive study was conducted in 50 cases of CSOM with actively discharging ears for a period of one year starting from February 2013. For all the cases aural swabs were collected from the diseased ear and were used for direct microscopic examination in potassi um hydroxide wet mount. Ear swab was cultured on Sabouraud’s dextrose agar plate for fungal cultures. The patient characteristics were prospectively recorded and results were analysed. CONCLUSION : There is high prevalence of coexisting fungal infection in actively discharging ears of CSOM patients

  6. Nanosecond barrier discharge in a krypton/helium mixture containing mercury dibromide: Optical emission and plasma parameters

    Malinina, A. A.; Starikovskaya, S. M.; Malinin, A. N.

    2015-01-01

    Spectral and electrical characteristics of atmospheric-pressure nanosecond barrier discharge plasma in a HgBr2/Kr/He mixture have been investigated. The discharge was initiated by positive 10-kV voltage pulses with a rise time of 4 ns and a half-amplitude duration of 28 ns. Emission from exciplex HgBr ( B 2Σ{1/2/+} - X 2Σ{1/2/+}) and KrBr ( B 2Σ{1/2/+} - X 2Σ{1/2/+}, C3/2-AΠ1/2, D1/2-AΠ1/2) molecules have been studied. From the time evolution of the B-X transition spectra of the HgBr molecule (502 nm) and KrBr molecule (207 nm), a mechanism of the formation of the exciplex molecules in the nanosecond discharge has been deduced. The distributions of the energies and rates of the processes responsible for emission from HgBr and KrBr molecules have been analyzed by numerically solving the Boltzmann equation for the electron distribution function. Experiments have confirmed the possibility of optimizing the voltage supply pulse for maximizing the efficiency of simultaneous emission in the UV and visible (green) spectral ranges from atmospheric-pressure discharge in the HgBr2/Kr/He mixture.

  7. Theoretical provisions for the discharge at TJ-1 (Preliminary study)

    Guasp, J.

    1981-01-01

    Using the transport code PLASMATOR a numerical study about the TJ-1 discharge (a Tokamak close to be installed at JEN) has been made, observing the behaviour under huge variations on the transport coefficients as well as on density and current. Noteworthy a scaling law of the kind τ E ∼n θ has been contested at not too high density, The model insensibility upon the initial values has been confirmed and the effects of variations on the recycling coefficient and the rate rise of current studied too. Finally comparisons with alternative models have been accomplished. (Author) 29 refs

  8. Studies of nanosecond pulse surface ionization wave discharges over solid and liquid dielectric surfaces

    Petrishchev, Vitaly; Leonov, Sergey; Adamovich, Igor V

    2014-01-01

    Surface ionization wave discharges generated by high-voltage nanosecond pulses, propagating over a planar quartz surface and over liquid surfaces (distilled water and 1-butanol) have been studied in a rectangular cross section test cell. The discharge was initiated using a custom-made, alternating polarity, high-voltage nanosecond pulse plasma generator, operated at a pulse repetition rate of 100–500 Hz, with a pulse peak voltage and current of 10–15 kV and 7–20 A, respectively, a pulse FWHM of ∼100 ns, and a coupled pulse energy of 2–9 mJ/pulse. Wave speed was measured using a capacitive probe. ICCD camera images demonstrated that the ionization wave propagated predominantly over the quartz wall or over the liquid surface adjacent to the grounded waveguide placed along the bottom wall of the test cell. Under all experimental conditions tested, the surface plasma ‘sheet’ was diffuse and fairly uniform, both for positive and negative polarities. The parameters of ionization wave discharge propagating over distilled water and 1-butanol surfaces were close to those of the discharge over a quartz wall. No perturbation of the liquid surface by the discharge was detected. In most cases, the positive polarity surface ionization wave propagated at a higher speed and over a longer distance compared to the negative polarity wave. For all three sets of experiments (surface ionization wave discharge over quartz, water and 1-butanol), wave speed and travel distance decreased with pressure. Diffuse, highly reproducible surface ionization wave discharge was also observed over the liquid butanol–saturated butanol vapor interface, as well as over the distilled water–saturated water vapor interface, without buffer gas flow. No significant difference was detected between surface ionization discharges sustained using single-polarity (positive or negative), or alternating polarity high-voltage pulses. Plasma emission images yielded preliminary evidence of charge

  9. Study and optimization of the partial discharges in capacitor model ...

    that the main cause of failure of these devices is the appearance of partial discharges initiated on edges of armatures. These devices can quickly slam if discharges occur continuously during the liquid impregnation. One of the criteria for selecting impregnating liquids is the behavior of gas bubbles when discharges occur.

  10. Experimental study of the negative glow and cathode sheath of an electron beam discharge

    Zeller, Philippe

    1988-01-01

    This research thesis reports the study of a middle-pressure (0.1-5 Torr) discharge in which a negative-glow-type plasma is created by a continuous electron beam (1 to 10 keV, 1 to 30 mA/cm 2 ). Such a discharge is characterised by a highly abnormal cathodic drop with a beam generation displaying an electric efficiency close to 1. In a first part, the author presents the main operation characteristics, discharge regimes and emission spectrum, and discusses bibliographical data related to cathode emission processes and to the distribution function of plasma electron velocities. The author then describes an original method of measurement of plasma conductivity. In the next part, he reports the study of the cathode region in which the electron beam generation occurs. The electric field has been measured in this region by using spatially resolved laser opto-galvanic spectroscopy. Results highlight an essentially linear spatial decay of the field. Besides, and based on these results, the author indicates scale laws leading to simple relationships between discharge parameters [fr

  11. A study into the treatability of ochreous mine water discharges

    Clark, C J; Crawshaw, D H

    1979-01-01

    The oxidation of ferrous salts in solution from waste-water discharges from 3 abandoned and flooded mines near Bromley, Lancs, (UK) has since 1968 caused discoloration in the Calder River. Deposition and dilution decreases the ochreous effect, but the iron oxide is harmful to the benthos by producing a low dissolved-oxygen environment. The Calder River is only a Class 4 river below the confluence with the stream which carried the mine waters, and pilot-plant studies and field trials are described to determine the feasibility of full- scale treatment of the stream waters, resulting in the recommendation of lagoon treatment followed by neutralization.

  12. Experimental study of spatial distribution of Ar glow discharge plasma

    Guo, X.M.; Zhou, T.D.; Pai, S.T.

    1996-01-01

    The characteristics of the spatial distribution of Ar glow discharge plasma were experimentally investigated. By means of direct comparisons between theory and experiment, the effects of the variation of gap separation, gas pressure, and electrode radius on the spatial distributions of electron density and electric field were studied. Results indicate that the maximum electron density moves toward the cathode as the gap separation or gas pressure increases while variation of electrode radius produces little effect. Predictions from a theoretical model have been experimentally verified. General agreements between theory and experiment were found to be reasonably good except in the cathode region, where discrepancy exists. copyright 1996 American Institute of Physics

  13. Angina - discharge

    Chest pain - discharge; Stable angina - discharge; Chronic angina - discharge; Variant angina - discharge; Angina pectoris - discharge; Accelerating angina - discharge; New-onset angina - discharge; Angina-unstable - discharge; ...

  14. Comparative Study of White Layer Characteristics for Static and Rotating Workpiece during Electric Discharge Machining

    SHAHID MEHMOOD

    2017-10-01

    Full Text Available EDMed (Electric Discharge Machined surfaces are unique in their appearance and metallurgical characteristics, which depend on different parameter such as electric parameters, flushing method, and dielectric type. Conventionally, in static workpiece method the EDM (Electric Discharge Machining is performed by submerging both of the tool and workpiece in dielectric liquid and side flushing is provided by impinging pressurized dielectric liquid into the gap. Another flushing method has been investigated in this study, in which, instead of side flushing the rotation motion is provided to the workpiece. Surface characteristics for both flushing methods are determined and compared in this study. The investigated surface characteristics are: surface roughness, crater size, surface morphology, white layer thickness and composition. These investigations are performed using optical and SEM (Scanning Electron Microscope. Statistical confidence limits are determined for scattered data of surface roughness. It is found that the white layer thickness and surface roughness are directly proportional to discharge current for both flushing methods. The comparison has shown that the side flushing of statics workpiece gives thicker white layer and lower surface finish as compared to the flushing caused by the rotation of workpiece

  15. Experimental study of electrical discharge drilling of stainless steel UNS S30400

    Hanash, E. A. H.; Ali, M. Y.

    2018-01-01

    In this study, overcut and taper angle were investigated in machining of stainless steel UNS S30400 against three different electrical discharge machining parameters which are electric current (Ip), pulse on-time (Ton) and pulse off-time (Toff). The electrode used was of 1 mm diameter with aspect ratio of 10. Dimensional accuracy was measured by evaluating overcut and taper angle. Those two measurements were performed using optical microscope model (Olympus BX41M, Japan). The experimentation planning, evaluation, analysis and optimization have been carried out using DOE software version 10.0.3 RSM based method with total number of twenty experiments. The research reveals that, discharge current was found to have the most significant effect on overcut and taper angle followed by pulse on-time and pulse off-time. As the discharge current and pulse on-time increase, overcut and taper angle are increased. However, when pulse off-time increases, overcut and taper angle decrease. The outcome result of this study will be very useful in the manufacturing industry to select the appropriate parameters for the selected work material. The model has shown a great accuracy with percentage error of less than 5%.

  16. Comparative study of white layer characteristics for static and rotating workpiece during electric discharge machining

    Mehmood, S.; Shah, M.; Anjum, N.A.

    2017-01-01

    EDMed (Electric Discharge Machined) surfaces are unique in their appearance and metallurgical characteristics, which depend on different parameter such as electric parameters, flushing method, and dielectric type. Conventionally, in static workpiece method the EDM (Electric Discharge Machining) is performed by submerging both of the tool and workpiece in dielectric liquid and side flushing is provided by impinging pressurized dielectric liquid into the gap. Another flushing method has been investigated in this study, in which, instead of side flushing the rotation motion is provided to the workpiece. Surface characteristics for both flushing methods are determined and compared in this study. The investigated surface characteristics are: surface roughness, crater size, surface morphology, white layer thickness and composition. These investigations are performed using optical and SEM (Scanning Electron Microscope). Statistical confidence limits are determined for scattered data of surface roughness. It is found that the white layer thickness and surface roughness are directly proportional to discharge current for both flushing methods. The comparison has shown that the side flushing of statics workpiece gives thicker white layer and lower surface finish as compared to the flushing caused by the rotation of workpiece. (author)

  17. A study on the equivalent electric circuit simulation model of DBD streamer and glow alternate discharge

    Yao, J; Zhang, Z T; Xu, S J; Yu, Q X; Yu, Z; Zhao, J S

    2013-01-01

    This paper presents a dynamic simulating model of the dielectric barrier discharge (DBD), structured as an equivalent electric circuit of the streamer and glow discharge generated alternately in DBD. The main parameters of DBD have been established by means of analysing the structural characteristics of a single discharge cell. An electrical comprehensive Simulink /MATLAB model was developed in order to reveal the interaction of the adjacent two discharge cell. A series of simulations was carried out in order to estimate the key structural parameters that affect the alternate streamer and glow discharge mode. The comparison results of experimental and simulate indicate that there exists a close similarity of the current waveforms graphic. Therefore, we can grasp a deep understanding mechanism of the dielectric barrier discharge and optimize the plasma reactor.

  18. Qualitative Parameters of Practice during University Studies

    Stasiunaitiene, Egle; Norkute, Odeta

    2011-01-01

    In this article, relevance of practice during university studies is highlighted, as well as the main stages of its organisation, qualitative parameters, as well as criteria and indicators that validate them are defined. Discussion on the idea that taking into consideration qualitative parameters of organising practice as a component of studies…

  19. Initial studies of submarine groundwater discharge in Mississippi coastal waters

    Shiller, A. M.; Moore, W. S.; Joung, D. J.; Box, H.; Ho, P.; Whitmore, L. M.; Gilbert, M.; Anderson, H.

    2017-12-01

    Submarine groundwater discharge (SGD) is a critical component of coastal ecosystems, affecting biogeochemistry and productivity. The SGD flux and effect on the ecosystem of the Mississippi (MS) Bight has not previously been studied. We have determined Ba, δ18O of water, and Ra-isotopes, together with nutrients, chlorophyll, and dissolved oxygen (DO) during multiple cruises from fall 2015 to summer 2016. Water isotope distributions (δ18O) show that, although the MS River Delta bounds the western side of the Bight, nonetheless, Mobile Bay and other local rivers are the Bight's dominant freshwater sources. But elevated dissolved Ba and Ra isotopes cannot be explained by river input. Spatially, SGD in the MS Bight occurs over a wide area, with hot spots near the barrier islands (e.g., Chandeleurs, Horn and Dauphin Islands) and the mouth of Mobile Bay, probably in association with old buried river channels, or dredged ship channels. Based on their high concentrations in saline groundwaters sampled on the barrier islands, the elevated Ba and Ra in MS Bight water are likely due to SGD. In subsurface waters, long-lived Ra isotopes were negatively correlated with DO during spring and summer 2016, suggesting direct discharge of DO-depleted groundwater and/or accumulation of SGD-derived Ra and microbial DO consumption under strongly stratified conditions. Our ongoing study suggests that seasonal variability in flushing, water stratification, and SGD input play important roles in biological production and bottom water hypoxia in the MS Bight.

  20. Numerical and Experimental Study of Amplitude Modulated Positive Corona Discharge

    Pablo Martín GOMEZ

    2014-12-01

    Full Text Available The electrical behavior of a modulated positive corona discharge loudspeaker was studied. A coaxial transducer in air was built using a central copper wire of 75 mm radius (inner electrode and a perforated tube of 11 mm (outer electrode. A high voltage DC supply provided the bias current and a sinusoidal signal was superimposed to measure the discharge admittance. The experimental results could not be matched to previously reported equivalent circuits with fixed components. Using the basic equations that describe the ion motion, a numerical model was proposed. The computed values matched well the experimental data and suggested an equivalent circuit composed of frequency dependent conductance and capacitance. This dependence is closely related to the ion travel time between electrodes (transit time. Simulations carried out at several inter-electrode distances could be synthesized in a single plot where the different results overlap and further emphasize the role of the transit time. This numerical model proved to be an efficient tool to simulate and design modulated corona transducers.

  1. Confinement studies of neutral beam heated discharges in TFTR

    Murakami, M.; Arunasalam, V.; Bell, J.D.; Stauffer, F.; Bell, M.G.; Bitte, M.; Blanchard, W.R.; Boody, F.; Britz, N.

    1985-11-01

    The TFTR tokamak has reached its original machine design specifications (I/sub p/ = 2.5 MA and B/sub T/ = 5.2T). Recently, the D/sup 0/ neutral beam heating power has been increased to 6.3 MW. By operating at low plasma current (I/sub p/ approx. = 0.8 MA) and low density anti n/sub e/ approx. = 1 x 10/sup 19/m/sup -3/), high ion temperatures (9 +- keV) and rotation speeds (7 x 10/sup 5/ m/s) have been achieved during injection. At the opposite extreme, pellet injection into high current plasmas has been used to increase the line-average density to 8 x 10/sup 19/m/sup -3/ and the central density to 1.6 x 10/sup 20/m/sup -3// This wide range of operating conditions has enabled us to conduct scaling studies of the global energy confinement time in both ohmically and beam heated discharges as well as more detailed transport studies of the profile dependence. In ohmic discharges, the energy confinement time is observed to scale linearly with density only up to anti n/sub e/ approx. 4.5 x 10/sup 19/m/sup -3/ and then to increase more gradually, achieving a maximum value of approx. 0.45 s. In beam heated discharges, the energy confinement time is observed to decrease with beam power and to increase with plasma current. With P/sub b/ = 5.6 MW, anti n/sub e/ = 4.7 x 10/sup 19/m/sup -3/, I/sub p/ = 2.2 MA and B/sub T = 4.7T, the gross energy confinement time is 0.22 s and T/sub i/(0) = 4.8 keV. Despite shallow penetration of D/sup 0/ beams (at the beam energy less than or equal to 80 keV with low species yield), tau/sub E/(a) values are as large as those for H/sup 0/ injection, but central confinement times are substantially greater. This is a consequence of the insensitivity of the temperature and safety factor profile shapes to the heating profile. The radial variation of tau/sub E/ is even more pronounced with D/sup 0/ injection into high density pellet-injected plasmas. 25 refs.

  2. Theoretical and experimental study of a thruster discharging a weight

    Michaels, Dan; Gany, Alon

    2014-06-01

    An innovative concept for a rocket type thruster that can be beneficial for spacecraft trajectory corrections and station keeping was investigated both experimentally and theoretically. It may also be useful for divert and attitude control systems (DACS). The thruster is based on a combustion chamber discharging a weight through an exhaust tube. Calculations with granular double-base propellant and a solid ejected weight reveal that a specific impulse based on the propellant mass of well above 400 s can be obtained. An experimental thruster was built in order to demonstrate the new idea and validate the model. The thruster impulse was measured both directly with a load cell and indirectly by using a pressure transducer and high speed photography of the weight as it exits the tube, with both ways producing very similar total impulse measurement. The good correspondence between the computations and the measured data validates the model as a useful tool for studying and designing such a thruster.

  3. Study of the striated nature of a glow discharge

    Hernandez A, M.

    1995-01-01

    In an investigation in progress here, plasma diagnostics and detection of standing and moving striations is being made in a discharge in Argon at pressures of 2 x 10 -1 to 9 x 10 -1 mb and currents of 2 to 9 m-amp inside an discharge tube. Measurement of the temperature of the electrons, the concentration of electrons and the plasma potential are obtained in different places of the discharge by the double probe method, together with the computation system reported in [1]. In similar way an experimental work of the striated column in a discharge plasma to find the regimen of appearance of the standing and moving striations show some properties of moving striations (frequency and velocity) and standing striations. Two different oscilations are observed in motion in contrary directions along the discharge tube with a photomultiplier. (Author)

  4. Study of a new direct current atmospheric pressure glow discharge in helium

    Gielniak, B. [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany); Fiedler, T. [Johannes Gutenberg-University Mainz, Institute for Inorganic and Analytical Chemistry, Duesbergweg 10-14, 55128 Mainz (Germany); Broekaert, J.A.C., E-mail: jose.broekaert@chemie.uni-hamburg.de [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, 20146 Hamburg (Germany)

    2011-01-15

    In this study a new DC-APGD operated in He was developed and characterized. The discharge is operated at 0.9 kV and about 25-35 mA and at a gas flow of 100 ml/min. The source was spectroscopically studied and parameters such as the rotational temperature (T{sub rot}), the excitation temperature (T{sub exc}), the ionization temperature (T{sub ion}) and the electron number density (n{sub e}) were determined. The current-voltage characteristic of the source was studied as well. At optimized conditions the discharge operates in the normal region of the current-voltage characteristic. Rotational and excitation temperatures determined with the use of OH band and Fe I lines as thermometric species were of the order of about 900-1200 and 4500-5500 K, respectively. This indicates that despite of the atmospheric pressure, the discharge is not in LTE. Spatially resolved temperature measurements were performed with axial as well as radial resolution and showed relatively flat profiles. Axially resolved emission intensity profiles for several species such as H, N{sub 2}, N{sub 2}{sup +}, OH, He and Hg were determined. It also was found that H{sub 2} introduced into the He by electrolysis of acid solutions such as in ECHG considerably increases the spectroscopically measured gas temperatures but decreases the analyte line intensities, as shown for Hg.

  5. Studies on nitric oxide removal in simulated gas compositions under plasma-dielectric/catalytic discharges

    Rajanikanth, B.S.; Rout, Satyabrata

    2001-01-01

    Application of pulsed electrical discharges for gas cleaning is gaining prominence, mainly from the energy consideration point of view. This present paper presents recent work on applying the electrical discharge plasma technology for treating gaseous pollutants, in general, and nitric oxide, in particular, as this is one of the major contributors to air pollution. The present work focuses attention on pulsed electrical discharge technique for nitric oxide removal from simulated gas compositions and study of effect of packed dielectric pellets, with and without a coating of catalyst, on the removal process. Experiments were conducted in a cylindrical corona reactor energized by repetitive high voltage pulses. The effects of various parameters, viz. pulse voltage magnitude, pulse frequency, initial nitric oxide concentration and gas mixture composition on nitric oxide removal efficiency, are discussed. When the reactors were filled with different dielectric pellets like, barium titanate, alumina, and alumina coated with palladium catalyst, the improvement in nitric oxide removal efficiency is studied and discussed. The power dissipated in the reactor and the energy consumed per nitric oxide molecule removed was calculated. Further results and comparative study of various cases are presented in the paper

  6. Study of a new direct current atmospheric pressure glow discharge in helium

    Gielniak, B.; Fiedler, T.; Broekaert, J.A.C.

    2011-01-01

    In this study a new DC-APGD operated in He was developed and characterized. The discharge is operated at 0.9 kV and about 25-35 mA and at a gas flow of 100 ml/min. The source was spectroscopically studied and parameters such as the rotational temperature (T rot ), the excitation temperature (T exc ), the ionization temperature (T ion ) and the electron number density (n e ) were determined. The current-voltage characteristic of the source was studied as well. At optimized conditions the discharge operates in the normal region of the current-voltage characteristic. Rotational and excitation temperatures determined with the use of OH band and Fe I lines as thermometric species were of the order of about 900-1200 and 4500-5500 K, respectively. This indicates that despite of the atmospheric pressure, the discharge is not in LTE. Spatially resolved temperature measurements were performed with axial as well as radial resolution and showed relatively flat profiles. Axially resolved emission intensity profiles for several species such as H, N 2 , N 2 + , OH, He and Hg were determined. It also was found that H 2 introduced into the He by electrolysis of acid solutions such as in ECHG considerably increases the spectroscopically measured gas temperatures but decreases the analyte line intensities, as shown for Hg.

  7. Comparative studies of high-frequency and direct current molecular gas discharges

    Goichman, V.H.; Goldfarb, V.M.; Tendler, M.B.

    1975-01-01

    Electron gas parameters, gas temperatures, ionization and thermal instability are found to be markedly different in direct current glow discharges from capactive electrodless high frequency discharge even when equal net power input is provided. It is reasonable to expect that the combined discharge containing both types of discharges mentioned above may be expected to improve significantly both the steady-state and transient characteristics of the plasma. The characteristics of different discharges in air, nitrogen air-CO 2 -He mixture have been compared. Because of the lack of the direct electrical methods for measurements of the hf plasma, exphasis in this investigation has been laid on both theoretical) based on the analytical expression for electron energy distribution function received previously and experimental spectroscopic evaluations of the plasma parameters. (Auth.)

  8. Study and optimization of the partial discharges in capacitor model ...

    The initial potential as well as the temperature are known to influence the partial discharge ... The development of electrostatic industry has ... the liquid impregnation. One of the ..... the Surface of Corona charged Uniforms layers of HIPS.

  9. Impurity studies and discharge cleaning in Doublet III

    Marcus, F.B.

    1979-10-01

    The goal of present and next generation tokamak experiments is to produce high-density, high-purity plasmas during high-power, extended-duration discharges. Plasma discharges with Z/sub eff/ values near unity and low concentrations of medium and high-Z metallic impurities have been obtained in Doublet III using a combination of low-power hydrogen discharge cleaning, gas puffing, precise plasma shape and position control, and high-Z limiters. Analysis of the first wall surface and residual gas impurities confirmed that clean conditions have been achieved. The high-Z limiters showed very limited amounts of melting or arcing. The progress of the wall cleaning process was monitored by three diagnostic techniques: Auger electron spectroscopy of metallic samples at the vessel wall, residual gas analysis, and the resistivity of full power discharges

  10. Laser ablation/ionization studies in a glow discharge

    Hess, K.R.; Harrison, W.W.

    1985-01-01

    The pin cathode glow discharge is used in the laboratory as an atomization/ionization source for a variety of applications, including solids mass spectrometry. Coupled with a tunable dye laser, the glow discharge may also serve as an atom reservoir for resonance ionization mass spectrometry in which the laser ionizes the discharge sputtered atoms. By tightly focusing the laser onto solid samples, various ablation effects may also be investigated. The laser may be used to generate an ionized plasma which may be directly analyzed by mass spectrometry. Alternatively, the ablated neutral atoms may be used in post-ablation excitation/ionization processes, in this case the glow discharge. The results of these investigations are the basis of this paper

  11. Impurity studies and discharge cleaning in Doublet III

    Marcus, F.B.

    1979-10-01

    The goal of present and next generation tokamak experiments is to produce high-density, high-purity plasmas during high-power, extended-duration discharges. Plasma discharges with Z/sub eff/ values near unity and low concentrations of medium and high-Z metallic impurities have been obtained in Doublet III using a combination of low-power hydrogen discharge cleaning, gas puffing, precise plasma shape and position control, and high-Z limiters. Analysis of the first wall surface and residual gas impurities confirmed that clean conditions have been achieved. The high-Z limiters showed very limited amounts of melting or arcing. The progress of the wall cleaning process was monitored by three diagnostic techniques: Auger electron spectroscopy of metallic samples at the vessel wall, residual gas analysis, and the resistivity of full power discharges.

  12. Analysis of case studies - mining, milling and discharges

    McEwan, A.C.

    2000-01-01

    This analysis paper reviews case studies on mining and milling and on radioactive discharges. An outline is given of each of the case studies presented from the perspectives of the study background, the criteria followed in remediation, the decision making process, outcomes achieved, and an evaluation in relation to radiological criteria that are recommended internationally. Site remediation after mining and milling operations may be driven more by aesthetic and environmental concerns than radiological criteria, particularly in more populated areas. The cases illustrated that it is highly desirable that stakeholders, including the public, are involved in decision making at an early stage with agreement on remediation outcomes. In particular, the exposure pathways and dose assessment models employed should generally be agreed with or approved by the regulatory authority prior to remediation work. In the case of remediated properties at Grand Junction, Colorado, it appears the cleanup criteria employed were below or consistent with those applicable to practices, although the situation was one of intervention, and this raises a question as to the cost effectiveness of the cleanup. For some remediation projects there are long term ownership issues arising out of the need for extended public or state oversight of engineered structures or active water treatment facilities, but for these cases ownership issues did not arise for purely radiological reasons. (author)

  13. Experimental study of the processes accompanying argon breakdown in a long discharge tube at a reduced pressure

    Meshchanov, A. V.; Ionikh, Yu. Z., E-mail: y.ionikh@spbu.ru; Shishpanov, A. I.; Kalinin, S. A. [St. Petersburg State University (Russian Federation)

    2016-10-15

    Results are presented from experimental studies of the breakdown stage of a low-pressure discharge (1 and 5 Torr) in a glass tube the length of which (75 cm) is much larger than its diameter (2.8 cm). Breakdowns occurred under the action of positive voltage pulses with an amplitude of up to 9.4 kV and a characteristic rise time of 2–50 μs. The discharge current in the steady-state mode was 10–120 mA. The electrode voltage, discharge current, and radiation from the discharge gap were detected simultaneously. The dynamic breakdown voltage was measured, the prebreakdown ionization wave was recorded, and its velocity was determined. The dependence of the discharge parameters on the time interval between voltage pulses (the socalled “memory effect”) was analyzed. The memory effect manifests itself in a decrease or an increase in the breakdown voltage and a substantial decrease in its statistical scatter. The time interval between pulses in this case can reach 0.5 s. The effect of illumination of the discharge tube with a light source on the breakdown was studied. It is found that the irradiation of the anode region of the tube by radiation with wavelengths of ≤500 nm substantially reduces the dynamic breakdown voltage. Qualitative explanations of the obtained results are offered.

  14. Program for parameter studies of steam generators

    Mathisen, R.P.

    1982-11-01

    R2-GEN is a computer code for stationary thermal parameter studies of steam generators. The geometry and data are valid for Ringhals-2 generators. Subroutines and relevant calculations are included. The program is based on a heterogeneous flow model and some applications on tubes with varying contamination are presented. (G.B.)

  15. Experimental study of unipolar arcs in a low pressure mercury discharge

    Johnson, C.T.

    1979-01-01

    An experimental study of unipolar arcs was conducted in a low pressure mercury discharge inductively heated with RF. The results were found to be consistent with the concept of a sheath mechanism for driving the unipolar arcs. Floating double-probe measurements of the unipolar arc plasma parameters yielded electron temperatures of approx. 2 eV and electron number densities of approx. 1 x 10 11 cm -3 assuming quasi-neutral plasma conditions. The variation of the unipolar arc current with: (1) the RF power input; and (2) the metal surface area exposed to the plasma verified the predicted dependence of the arc current on the plasma parameters and the metal surface area. Finally, alternative mechanisms for sustaining the observed arcs by high frequency rectification were ruled out on the basis of the recorded current waveforms of the unipolar arcs

  16. Preliminary study on the modelling of negative leader discharges

    Arevalo, L; Cooray, V

    2011-01-01

    Nowadays, there is considerable interest in understanding the physics underlying positive and negative discharges because of the importance of improving lightning protection systems and of coordinating the insulation for high voltages. Numerical simulations of positive switching impulses made in long spark gaps in a laboratory are achievable because the physics of the process is reasonably well understood and because of the availability of powerful computational methods. However, the existing work on the simulation of negative switching discharges has been held up by a lack of experimental data and the absence of a full understanding of the physics involved. In the scientific community, it is well known that most of the lightning discharges that occur in nature are of negative polarity, and because of their complexity, the only way to understand them is to generate the discharges in laboratories under controlled conditions. The voltage impulse waveshape used in laboratories is a negative switching impulse. With the aim of applying the available information to a self-consistent physical method, an electrostatic approximation of the negative leader discharge process is presented here. The simulation procedure takes into consideration the physics of positive and negative discharges, considering that the negative leader propagates towards a grounded electrode and the positive leader towards a rod electrode. The simulation considers the leader channel to be thermodynamic, and assumes that the conditions required to generate a thermal channel are the same for positive and negative leaders. However, the magnitude of the electrical charge necessary to reproduce their propagation and thermalization is different, and both values are based on experimental data. The positive and negative streamer development is based on the constant electric field characteristics of these discharges, as found during experimental measurements made by different authors. As a computational tool

  17. Study on the onset of DC diaphragm glow discharge

    Jin, Xinglong; Wang, Xiaoyan; Zhang, Hongmei; Ren, Hongxia

    2013-01-01

    In this paper, the DC diaphragm glow discharge (DGD) occurred around the small hole on quartz tube between two submersed graphite electrodes and the onset of DGD was systematically investigated. It was found that critical voltage (V D ) decreased with the increasing conductivity, and then maintained at about 620 V. When the hole diameter increased from 1.0 mm to 2.5 mm, H 2 O 2 formation and AO discoloration in anolyte increased with the increase of the hole diameter. In addition, the effect of electrolyte constituents on H 2 O 2 formation and AO discoloration in anolyte induced by DGD was also studied. The concentration of H 2 O 2 and AO discoloration in anolyte was close in inert electrolyte such as Na 2 SO 4 and Na 2 HPO 4 solution. The concentration of H 2 O 2 and AO discoloration rate in Na 2 CO 3 and NaAc solution was lower than those in Na 2 SO 4 and Na 2 HPO 4 solution, due to their capture ability for ·OH. However, NaCl showed enhancing effect on AO discoloration, although it consumed a certain amount of H 2 O 2 . The energy efficiencies of AO discoloration and H 2 O 2 formation were also compared with those of other DGD reactor.

  18. Case Study on Justification: High Intensity Discharge Lamps. Annex II

    2016-01-01

    High intensity discharge lamps produce bright white light of a high intensity in an energy efficient manner. These lamps are typically used in large numbers in public and professional settings such as shops, warehouses, hotels and offices. They are also used in outdoor applications to illuminate streets, buildings, statues, flags and gardens and further as architectural lighting. They also have applications associated with film projection in cinemas, manufacture of semiconductors, fluorescence endoscopy and microscopy, schlieren photography, hologram projection, ultraviolet curing, sky beamers and car headlights. Some types of high intensity discharge lamp, as well as certain other consumer products for lighting, contain radioactive substances for functional reasons. The radionuclides that are typically incorporated into high intensity discharge lamps are 85 Kr and 232 Th. Given the wide range of uses, specific decisions on justification may be required for different applications. A small number of safety assessments for high intensity discharge lamps have been carried out and published. No published decisions at the national level specifically addressing the justification of the use of high intensity discharge lamps have been identified

  19. Study of geometrical and operational parameters controlling the low frequency microjet atmospheric pressure plasma characteristics

    Kim, Dan Bee; Rhee, J. K.; Moon, S. Y.; Choe, W.

    2006-01-01

    Controllability of small size atmospheric pressure plasma generated at low frequency in a pin to dielectric plane electrode configuration was studied. It was shown that the plasma characteristics could be controlled by geometrical and operational parameters of the experiment. Under most circumstances, continuous glow discharges were observed, but both the corona and/or the dielectric barrier discharge characteristics were observed depending on the position of the pin electrode. The plasma size and the rotational temperature were also varied by the parameters. The rotational temperature was between 300 and 490 K, being low enough to treat thermally sensitive materials

  20. A Study of Coherent Radiation Generated in an Ablative Capillary Discharge

    Jakub Hübner

    2013-01-01

    Full Text Available Feasible soft-X-ray amplification in the CVI and NVII Balmer transition is investigated in a capillary discharge. The best conditions and parameters for the experimental set-up are found for an ablative capillary. The most optimistic results have shown that the gain would be greater than one, which is the condition for successful ASE (Amplified spontaneous emission in capillary discharges. The capillary discharge evolution is modeled using the NPINCH program, employing a one-dimensional physical model based on MHD equations. The information about the capillary discharge evolution is processed in the FLY, FLYPAPER, FLYSPEC programs, enabling the population to be modeled on specific levels during capillary discharge.

  1. Study of a pulsed capillary discharge with a modulated radius

    Broks, B.H.P.; Dijk, van W.; Mullen, van der J.J.A.M.; Veldhuizen, van E.M.

    2005-01-01

    In this contribution, we present a plasma physical model of a pulsed capillary discharge with a modulated radius. Using a 2D time-dependent model, we have modeled the plasma and wall properties of this channel. It was found that properties of the central plasma are different than the properties of a

  2. Improving discharge care: the potential of a new organisational intervention to improve discharge after hospitalisation for acute stroke, a controlled before–after pilot study

    Cadilhac, Dominique A; Andrew, Nadine E; Stroil Salama, Enna; Hill, Kelvin; Middleton, Sandy; Horton, Eleanor; Meade, Ian; Kuhle, Sarah; Nelson, Mark R; Grimley, Rohan

    2017-01-01

    Objective Provision of a discharge care plan and prevention therapies is often suboptimal. Our objective was to design and pilot test an interdisciplinary, organisational intervention to improve discharge care using stroke as the case study using a mixed-methods, controlled before–after observational study design. Setting Acute care public hospitals in Queensland, Australia (n=15). The 15 hospitals were ranked against a benchmark based on a composite outcome of three discharge care processes....

  3. A Different Approach to Studying the Charge and Discharge of a Capacitor without an Oscilloscope

    Ladino, L. A.

    2013-01-01

    A different method to study the charging and discharging processes of a capacitor is presented. The method only requires a high impedance voltmeter. The charging and discharging processes of a capacitor are usually studied experimentally using an oscilloscope and, therefore, both processes are studied as a function of time. The approach presented…

  4. [Study on A White-Eye Pattern in Dielectric Barrier Discharge by Optical Emission Spectrum].

    Zhu, Ping; Dong, Li-fang; Yang, Jing; Zhang, Yu; Zhang, Chao

    2015-06-01

    The white-eye pattern was firstly observed and investigated in a dielectric barrier discharge system in the mixture of argon and air whose content can be varied whenever necessary, and the study shows that the white-eye cell is an interleaving of three different hexagonal sub-structures: the center spot, the halo, and the ambient spots. The white-eye pattern is observed at a lower applied voltage. In this experiment, the heat capacity of water is high so that the water in water electrode is good at absorbing heat. In the process of pattern discharging the gas gap didn't increase its temperature, and the discharging phenomenon of this pattern has not changed. The temperature of the water electrodes almost keeps unchanged during the whole experiment, which is advantageous for the long-term stable measurement. Pictures recorded by ordinary camera with long exposure time in the same argon content condition show that the center spot, the halo, and the ambient spots og the white-eye pattern have different brightness, which may prove that their plasma states are different. And, it is worth noting that there are obvious differences of brightness not only on the center spot, the halo, and the ambient spots at the same pressure but also at the different pressure, which shows that its plasma state also changed with the variation of the pressure. Given this, in this experiment plasma temperatures of the central spot, halo, and ambient spots in a white-eye pattern at different gas pressure were studied by using optical emission spectra. The molecular vibration temperature is investigated by the emission spectra of nitrogen band of second positive system ( C3Πu --> B3Πg ). The electron excitation temperature is researched by the relative intensity ratio method of spectral lines of Ar I 763. 51 nm (2P6 --> 1S5) and Ar I 772. 42 nm (2P2 --> 1S3). The electronic density is investigated by the broadening of spectral line 696.5 nm. Through the analysis of experimental results, it

  5. Experimental and spectroscopic study of flow actuation phenomena using DC discharge at a Mach 3 flow.

    Shin, J.; Narayanaswamy, V.; Raja, L.; Clemens, N.

    2006-10-01

    A study of flow actuation phenomena of DC discharge will be presented. An array of pin-like electrodes is flush mounted on a co-planar ceramic actuator that is inserted in the test section. The different discharge structures -- diffuse, constricted, and mixed mode -- are observed in the presence of a flow. A discernable actuation, as visualized by schlieren imaging, is achieved by diffuse discharge, whereas the constricted discharge does not show detectable flow perturbation at the same current. The flow actuation in the form of an induced oblique shock occurs within one frame of laser schlieren imaging at 4.5 kHz. Rotational (gas) and vibrational temperatures are measured by fitting spectra of N2 and N2+ bands near 365-395 nm. Electronic temperatures are measured using Boltzmann plot of Fe (I) lines. Gas temperatures of diffuse discharges drop from ˜1500 K to ˜500 K in the presence of a flow while vibrational and electronic temperatures remain almost the same at ˜3000 K and ˜1.25 eV, respectively. Gas temperatures of constricted discharge are found to be similar with diffuse discharge whereas only diffuse discharge shows an actuation. An examination of spatial extent of the plasma reveals that the diffuse discharge occupies a larger region of the flow than the constricted discharge. This indicates that the flow actuation is dependent on flow dilatation which is governed by temperature rise as well as the spatial extent over which the temperature rise is observed.

  6. Experimental study of surface dielectric barrier discharge in air and its ozone production

    Pekárek, Stanislav

    2012-01-01

    For surface dielectric barrier discharge in air we studied the effects of frequency of the driving voltage on dissipated power, asymmetry of amplitudes of the discharge voltage, discharge UV emission, ozone production, ozone production of the discharge with TiO 2 and of the discharge in magnetic field. We found that for a particular voltage the dissipated power is higher for the frequency of the driving voltage of 26.3 kHz than for the frequency of 10.9 kHz; peak values of the positive half-periods of the discharge voltage are higher than peak values of the negative half-periods; intensity of the discharge UV emissions for wavelengths of 320-420 nm is for both frequencies a linear function of power; maximum ozone concentration for the frequency of the driving voltage of 26.3 kHz is obtained with smaller power than for the frequency of 10.9 kHz; placement of TiO 2 particles into the discharge chamber increases for both frequencies of the driving voltage maximum ozone concentration produced by the discharge and for the frequency of the driving voltage of 26.3 kHz increases ozone production yield. Finally, there is no observable effect of magnetic field on concentration of ozone produced by the discharge as well as on production yield. (paper)

  7. Predictors of Discharge Disposition in Older Adults With Burns: A Study of the Burn Model Systems.

    Pham, Tam N; Carrougher, Gretchen J; Martinez, Erin; Lezotte, Dennis; Rietschel, Carly; Holavanahalli, Radha; Kowalske, Karen; Esselman, Peter C

    2015-01-01

    Older patients with burn injury have a greater likelihood for discharge to nursing facilities. Recent research indicates that older patients discharged to nursing facilities are two to three times as likely to die within a 3-year period relative to those discharged to home. In light of these poor long-term outcomes, we conducted this study to identify predictors for discharge to independent vs nonindependent living status in older patients hospitalized for burns. We retrospectively reviewed all older adults (age ≥ 55 years) who were prospectively enrolled in a longitudinal multicenter study of outcomes from 1993 to 2011. Patient, injury, and treatment outcomes data were analyzed. Recognizing that transfer to inpatient rehabilitation may have impacted final hospital discharge disposition: we assessed the likelihood of inpatient rehabilitation stay, based on identified predictors of inpatient rehabilitation. We subsequently performed a logistic regression analysis on the clustered, propensity-matched cohort to assess associations of burn and injury characteristics on the primary outcome of final discharge status. A total of 591 patients aged ≥55 years were treated and discharged alive from three participating U.S. burn centers during the study period. Mean burn size was 14.8% (SD 11.2%) and mean age was 66.7 years (SD 9.3 years). Ninety-three patients had an inpatient rehabilitation stay before discharge (15.7%). Significant factors predictive of inpatient rehabilitation included a burn >20% TBSA, mechanical ventilation, older age, range of motion deficits at acute care discharge, and study site. These factors were included in the propensity model. Four hundred seventy-one patients (80%) were discharged to independent living status. By matched propensity analysis, older age was significantly associated with a higher likelihood of discharge to nonindependent living (P burn centers need to be elucidated to better understand discharge disposition status in older

  8. Application of surface electrical discharges to the study of lightning strikes on aircraft

    Boulay, J. L.; Larigaldie, S.

    1991-01-01

    Considered here is the characterization of surface discharges which provide a facility complementary to that of artificially triggered lightning. General characteristics of a simplified surface discharge, including current waveforms and the constitution of a surface discharge are outlined, and the application of this approach to the study of aircraft lightning strikes is considered. Representations of leader-streamer and return-stroke phases are discussed, and the application to the two-dimensional discharge phase is covered. It is noted that the fact that the initiation times of surface discharges could be controlled, and the path followed by the discharge channels could be predetermined, indicates that it is possible to produce a highly dedicated high performance instrumentation system.

  9. Pending studies at hospital discharge: a pre-post analysis of an electronic medical record tool to improve communication at hospital discharge.

    Kantor, Molly A; Evans, Kambria H; Shieh, Lisa

    2015-03-01

    Achieving safe transitions of care at hospital discharge requires accurate and timely communication. Both the presence of and follow-up plan for diagnostic studies that are pending at hospital discharge are expected to be accurately conveyed during these transitions, but this remains a challenge. To determine the prevalence, characteristics, and communication of studies pending at hospital discharge before and after the implementation of an electronic medical record (EMR) tool that automatically generates a list of pending studies. Pre-post analysis. 260 consecutive patients discharged from inpatient general medicine services from July to August 2013. Development of an EMR-based tool that automatically generates a list of studies pending at discharge. The main outcomes were prevalence and characteristics of pending studies and communication of studies pending at hospital discharge. We also surveyed internal medicine house staff on their attitudes about communication of pending studies. Pre-intervention, 70% of patients had at least one pending study at discharge, but only 18% of these were communicated in the discharge summary. Most studies were microbiology cultures (68%), laboratory studies (16%), or microbiology serologies (10%). The majority of study results were ultimately normal (83%), but 9% were newly abnormal. Post-intervention, communication of studies pending increased to 43% (p pending studies, but in usual practice, the presence of these studies has rarely been communicated to outpatient providers in the discharge summary. Communication significantly increased with the implementation of an EMR-based tool that automatically generated a list of pending studies from the EMR and allowed users to import this list into the discharge summary. This is the first study to our knowledge to introduce an automated EMR-based tool to communicate pending studies.

  10. Theoretical Study of Methods for Improving the Energy Efficiency of NOx Removal from Diesel Exhaust Gases by Silent Discharge

    Shoyama, Taiji; Yoshioka, Yoshio

    To improve the NO removal performance in silent discharge process, we investigated the influence of the physical parameters such as current density, channel radius and pulse duration of the one micro discharge under the constant reduced electric field strength. And influence of the micro discharges occurrence locations were also discussed. In order to analyze the NO removal process, we assumed that the pulse micro discharges occur repeatedly at the same location in static gas and that the chemical reactions induced by micro discharge forms many radicals, which react with pollutants and by-products. The conclusions we obtained are that lower current density, smaller discharge radius and shorter discharge duration improve NO removal efficiency. These results also mean that the lower discharge energy of the one micro discharge and the larger number of parallel micro discharges increase the NO removal performance. Therefore, to make the area of one micro discharge small is a desirable way to improve the NO removal performance. So we think that the glow like discharge might be more effective than the streamer like discharge mode. Next, using the two-dimensional model, which considered the influence of gas flow, we obtained a conclusion that the repeated micro discharges at different positions are very effective to increase the De-NOx performance. The reason is that the reaction of NO2+O→NO+O2 and ozone dissociation reactions are suppressed by the movement of the location of micro discharges.

  11. Computational Study of Anomalous Transport in High Beta DIII-D Discharges with ITBs

    Pankin, Alexei; Garofalo, Andrea; Grierson, Brian; Kritz, Arnold; Rafiq, Tariq

    2015-11-01

    The advanced tokamak scenarios require a large bootstrap current fraction and high β. These large values are often outside the range that occurs in ``conventional'' tokamak discharges. The GLF23, TGLF, and MMM transport models have been previously validated for discharges with parameters associated with ``conventional'' tokamak discharges. It has been demonstrated that the TGLF model under-predicts anomalous transport in high β DIII-D discharges [A.M. Garofalo et al. 2015 TTF Workshop]. In this research, the validity of MMM7.1 model [T. Rafiq et al. Phys. Plasmas 20 032506 (2013)] is tested for high β DIII-D discharges with low and high torque. In addition, the sensitivity of the anomalous transport to β is examined. It is shown that the MMM7.1 model over-predicts the anomalous transport in the DIII-D discharge 154406. In particular, a significant level of anomalous transport is found just outside the internal transport barrier. Differences in the anomalous transport predicted using TGLF and MMM7.1 are reviewed. Mechanisms for quenching of anomalous transport in the ITB regions of high-beta discharges are investigated. This research is supported by US Department of Energy.

  12. Study of the switching rate of gas-discharge devices based on the open discharge with counter-propagating electron beams

    Bokhan, P. A.; Gugin, P. P.; Lavrukhin, M. A.; Zakrevsky, Dm. E.

    2015-01-01

    The switching rate of gas-discharge devices “kivotrons” based on the open discharge with counter-propagating electron beams has been experimentally studied. Structures with 2-cm 2 overall cathode area were examined. The switching time was found to show a monotonic decrease with increasing the working-gas helium pressure and with increasing the voltage across the discharge gap at breakdown. The minimum switching time was found to be ∼240 ps at 17 kV voltage, and the maximum rate of electric-current rise limited by the discharge-circuit inductance was 3 × 10 12  A/s

  13. A Simplified Numerical Study of the Kr/Cl2 Plasma Chemistry in Dielectric Barrier Discharge

    Bachir, N. Larbi Daho; Belasri, A.

    2013-01-01

    In this paper, the generation of excimers and exciplexe radiation in mixtures of rare gas with halogen by homogeneous dielectric barrier discharge (DBD) is investigated. The typical characteristics of an excilamp based on KrCl* exciplexe molecules and the kinetic processes for the formation and the decay of this molecules in the Kr/Cl 2 mixture are studied. The computer model developed is based on the Kr/Cl 2 mixture chemistry, the equivalent electric circuit and the Boltzmann equations. The importance in the kinetic processes of some species such as the metastable state of Krypton (Kr*( 3 P 0,2 )) and the negative ion of chloride (Cl − ) is considered. The results illustrate the time variations of charged species (n e , Kr + , Cl − , Cl + , Cl + 2 , Kr + 2 ), excited atoms and molecules (Kr*( 3 P 0,2 ), Kr*( 3 P 1 ), Cl*, Cl* 2 ), the excimers (Kr* 2 , KrCl*(B), KrCl*(C), Kr 2 Cl*) and the UV photon concentrations (in 222 nm, 235 nm, 258 nm and 325 nm range). The effects of chlorine concentration and the total gas pressure in the Kr-Cl 2 discharge on the electric parameters and radiation emissions are investigated. (low temperature plasma)

  14. On the square arc voltage waveform model in magnetic discharge lamp studies

    Molina, Julio; Sainz Sapera, Luis; Mesas García, Juan José

    2011-01-01

    The current number of magnetic and electronic ballast discharge lamps in power distribution systems is increasing because they perform better than incandescent lamps. This paper studies the magnetic discharge lamp modeling. In particular, the arc voltage waveform is analyzed and the limitations of the square waveform model are revealed from experimental measurements.

  15. Experimental studies of equilibrium in a linear EXTRAP z-pinch discharge

    Drake, J.R.

    1982-10-01

    Experimental studies of the radial equilibrium condition in linear Extrap discharge have been carried out. Bennet like scaling, NT α I 2 sub (p), has been observed where N is the plasma line density, T is the tempreature and I sub (p) is the plasma discharge current. (Author)

  16. Studies of pellet acceleration with arc discharge heated propellants

    Schuresko, D.D.

    1986-01-01

    An arc discharge has been utilized to heat gaseous propellants in a pneumatic pellet gun. A cylindrical arc chamber is interposed between the propellant inlet valve and the gun breech and fitted with a ceramic insert for generating swirl in the incoming gas stream. The arc is initiated after the propellant valve opens and the breech pressure starts to rise; a typical discharge lasts 300 microseconds with peak currents up to 2 kA at arc voltages ranging from 100-400 V. The system is instrumented with piezoelectric pressure transducers at the propellant valve outlet, gun breech, and gun muzzle. The gun has been operated with 4 mm diameter polyurethane foam pellets (density = 0.14 g/cm 3 ), a 40 cm-long barrel, and various gas propellants at pressures exceeding 70 bar. At I/sub arc/ = 1 kA, V/sub arc/ = 200 V, with helium propellant, the arc produces a 2-3 fold prompt increase in P/sub breech/ and a delayed increase in P/sub muzzle/; the pellets exit the gun from 0.5-1.0 ms earlier than with the gas alone at 40% higher speeds. Comparisons with the so-called ideal gun theory and with full one-dimensional hydrodynamic calculations of the pellet acceleration will be presented

  17. Studies of pellet acceleration with arc discharge heated propellants

    Schuresko, D.D.

    1985-01-01

    An arc discharge has been utilized to heat gaseous propellants in a pneumatic pellet gun. A cylindrical arc chamber is interposed between the propellant inlet valve and the gun breech and fitted with a ceramic insert for generating swirl in the incoming gas stream. The arc is initiated after the propellant valve opens and the breech pressure starts to rise; a typical discharge lasts 300 microseconds with peak currents u to 2 kA at arc voltages ranging from 100 to 400 V. The system is instrumented with piezoelectric pressure transducers at the propellant valve outlet, gun breech, and gun muzzle. The gun has been operated with 4 mm diameter polyurethane foam pellets (density = 0.14 g/cm 3 ), a 40 cm-long barrel, and various gas propellants at pressures exceeding 70 bar. At I/sub arc/ = 1 kA, V/sub arc/ = 200 V, with helium propellant, the arc produces a 2 to 3 fold prompt increase in P/sub breech/ and a delayed increase in P/sub muzzle/; the pellets exit the gun from 0.5 to 1.0 ms earlier than with the gas alone at 40% higher speeds. Comparisons with the so-called ideal gun theory and with full one-dimensional hydrodynamic calculations of the pellet acceleration will be presented

  18. Modelling electric discharge chemistry

    McFarlane, J.; Wren, J.C.

    1991-07-01

    The chemistry occurring in a electric discharge was modelled to predict how it would be influenced by discharge conditions. The discharge was characterized by a calculated Boltzmann electron-energy distribution, from which rate constants for electron-molecule processes in air were determined. These rate constants were used in a chemical kinetics calculation that also included reactions between neutral molecules, ions, free radicals and electronically excited species. The model describes how the discharge chemistry was influenced by humidity, electric field, electron number density, and concentrations of key reagents identified in the study. The use of an electric discharge to destroy airborne contaminant molecules was appraised, the targeted contaminants being CF 2 Cl 2 , HCN, and SO 2 . The modelling results indicate that an electric discharge should be able to remove HCN and CF 2 Cl 2 effectively, especially if the discharge conditions have been optimized. Effective destruction is achieved with a moderate electric field (over 1 x 10 -15 V.cm 2 ), a substantial electron number density (over 1 x 10 12 cm -3 ), and the presence of H 2 0 in the process air. The residence time in the discharge was also shown to be important in contaminant destruction. An attempt was made to explain the results of the electric discharge abatement of SO 2 , a component of a simulated flue-gas mixture. Results from the model indicate that the discharge parameters that increase the concentration of hydroxyl radical also increase the rate of decomposition of SO 2 . An objective of the study was to explain the apparent enhancement of SO 2 destruction by the presence of a small amount of NO 2 . It was thought that a likely explanation would be the stabilization of HOSO 2 , an important intermediate in the oxidation of SO 2 by NO 2 . (49 figs., 14 tabs., 75 refs.)

  19. Using a Radiofrequency Identification System for Improving the Patient Discharge Process: A Simulation Study.

    Shim, Sung J; Kumar, Arun; Jiao, Roger

    2016-01-01

    A hospital is considering deploying a radiofrequency identification (RFID) system and setting up a new "discharge lounge" to improve the patient discharge process. This study uses computer simulation to model and compare the current process and the new process, and it assesses the impact of the RFID system and the discharge lounge on the process in terms of resource utilization and time taken in the process. The simulation results regarding resource utilization suggest that the RFID system can slightly relieve the burden on all resources, whereas the RFID system and the discharge lounge together can significantly mitigate the nurses' tasks. The simulation results in terms of the time taken demonstrate that the RFID system can shorten patient wait times, staff busy times, and bed occupation times. The results of the study could prove helpful to others who are considering the use of an RFID system in the patient discharge process in hospitals or similar processes.

  20. Study of a DC gas discharge with a copper cathode in a water flow

    Tazmeev, G. Kh.; Timerkaev, B. A.; Tazmeev, Kh. K.

    2017-07-01

    A dc gas discharge between copper electrodes in the current range of 5-20 A was studied experimentally. The discharge gap length was varied within 45-70 mm. The cathode was a 10-mm-diameter rod placed in the water flowing out from a dielectric tube. Three discharge configurations differing in the position of the cathode upper end with respect to the water surface were considered: (i) above water; (ii) flush with the water surface, and (iii) under water. The electric and optical characteristics of the discharge in the second configuration were studied in more detail. It is established that the discharge properties are similar to those of an electric arc. Considerable cathode erosion was observed in the third configuration. It is revealed that fine-dispersed copper grains form in the course of erosion.

  1. Study of electroweak parameters at LEP

    Blum, W.

    1991-10-01

    The measurement of the line shape and asymmetry parameters of the Z 0 in its leptonic and hadronic decays are reviewed. Progress is reported about a considerable increase in measurement accuracy. Several tests of the Standard Model confirm it to better than one per cent. New values for the effective mixing parameter are derived from the line shape parameters averaged over the four LEP experiments. The corresponding limits on the top mass are presented. (orig.)

  2. Studies on discharges in Micro Pattern Gaseous Detectors, towards a spark resistant THGEM detector

    Cantini, Cosimo; De Oliveira, Rui

    The problem afflicting any of MPGDs is the phenomenon of discharging which might be destructive in some highly energetic cases, at least being responsible of a slow aging of the detector. So far one solution has been cascading several gain elements (GEM, THGEM detectors) reducing the gain of each one; this method, spreading the charges along their path, reduce effectively the likelihood of a discharge but introduce more material due to the multiple stages of amplification. Our goal is developing a single stage THGEM detector which could withstand discharges, not reducing the gain, hence being still able to amplify low level ionizing particles while implementing some methodologies to reduce the damages due to discharge induced by high rate of particles’ flux and/or highly ionizing particles. This report describes the test bench set up to study discharges between simple structures, which are actually models of the bigger detector. The idea behind this approach is to reduce the complexity of the whole phenomen...

  3. Analysis of Effects of Cutting Parameters of Wire Electrical Discharge Machining on Material Removal Rate and Surface Integrity

    Tonday, H. R.; Tigga, A. M.

    2016-01-01

    As wire electrical discharge machining is pioneered as a vigorous, efficient and precise and complex nontraditional machining technique, research is needed in this area for efficient machining. In this paper, the influence of various input factors of wire electrical discharge machining (WEDM) on output variable has been analyzed by using Taguchi technique and analysis of variance. The design of experiments has been done and by applying L8 orthogonal arrays method and experiments have been conducted and collected required data. The objectives of the research are to maximize the material removal rate and to minimize the surface roughness value (Ra). Surface morphology of machined workpiece has been obtained and examined by employing scanning electron microscopy (SEM) technique. (paper)

  4. Analysis of Effects of Cutting Parameters of Wire Electrical Discharge Machining on Material Removal Rate and Surface Integrity

    Tonday, H. R.; Tigga, A. M.

    2016-02-01

    As wire electrical discharge machining is pioneered as a vigorous, efficient and precise and complex nontraditional machining technique, research is needed in this area for efficient machining. In this paper, the influence of various input factors of wire electrical discharge machining (WEDM) on output variable has been analyzed by using Taguchi technique and analysis of variance. The design of experiments has been done and by applying L8 orthogonal arrays method and experiments have been conducted and collected required data. The objectives of the research are to maximize the material removal rate and to minimize the surface roughness value (Ra). Surface morphology of machined workpiece has been obtained and examined by employing scanning electron microscopy (SEM) technique.

  5. Electric discharge during electrosurgery.

    Shashurin, Alexey; Scott, David; Zhuang, Taisen; Canady, Jerome; Beilis, Isak I; Keidar, Michael

    2015-04-16

    Electric discharge utilized for electrosurgery is studied by means of a recently developed method for the diagnostics of small-size atmospheric plasma objects based on Rayleigh scattering of microwaves on the plasma volume. Evolution of the plasma parameters in the near-electrode sheaths and in the positive column is measured and analyzed. It is found that the electrosurgical system produces a glow discharge of alternating current with strongly contracted positive column with current densities reaching 10(3) A/cm(2). The plasma electron density and electrical conductivities in the channel were found be 10(16) cm(-3) and (1-2) Ohm(-1) cm(-1), respectively. The discharge interrupts every instance when the discharge-driving AC voltage crosses zero and re-ignites again every next half-wave at the moment when the instant voltage exceeds the breakdown threshold.

  6. Study and optimization of magnetized ICRF discharges for tokamak wall conditioning and assessment of the applicability to ITER

    Wauters, T.

    2011-11-01

    This work is devoted to the study and optimization of the Ion Cyclotron Wall Conditioning (ICWC) technique. ICWC, operated in presence of the toroidal magnetic field, makes use of four main tokamak systems: the ICRF antennas to initiate and sustain the conditioning discharge, the gas injection valves to provide the discharge gas, the machine pumps to remove the wall desorbed particles, and the poloidal magnetic field system to optimize the discharge homogeneity. Additionally neutral gas and plasma diagnostics are required to monitor the discharge and the conditioning efficiency. In chapter 2 a general overview on ICWC is given. Chapter 3 treats the ICRF discharge homogeneity and the confinement properties of the employed magnetic field. In the first part we will discuss experimental facts on plasma homogeneity, and how experimental optimization led to its improvement. In the second part of the chapter the confinement properties of a partially ionized plasma in a toroidal magnetic field configuration with additional small vertical component are discussed. Chapter 4 gives an overview of experimental results on the efficiency of ICWC, obtained on TORE SUPRA, TEXTOR, JET and ASDEX Upgrade. In chapter 5 a 0D kinetic description of hydrogen-helium RF plasmas is outlined. The model, describing the evolution of ICRF plasmas from discharge initiation to the (quasi) steady state plasma stage, is developed to obtain insight on ICRF plasma parameters, particle fluxes to the walls and the main collisional processes. Chapter 6 presents a minimum structure for a 0D reservoir model of the wall to investigate in deeper detail the ICWC plasma wall interaction during isotopic exchange experiments. The hypothesis used to build up the wall model is that the same model structure should be able to describe the wall behavior during normal plasmas and conditioning procedures. Chapter 7 extrapolates the results to the envisaged application of ICWC on ITER

  7. Study on the characteristics of hysteresis loop and resistance of glow discharge plasma using argon gas

    Mathew, Prijil; Sajith Mathews, T.; Kurian, P. J.; Chattopadyay, P. K.

    2018-05-01

    Hysteresis in discharge current is produced in a low-pressure, magnetic field free, Glow discharge plasma by varying discharge voltage. The variation in area of the hysteresis loops with pressure, electrode distance and load resistor studied. To understand, the nonlinear behaviour of the I-V characteristics, the changes in gas resistance with electrode voltage, pressure and load resistor were studied. After many trials we propose the best suitable empirical equation for the exponential decrease of the gas resistance with electrode voltage as; R = Rmin + Ae-0.008V, which is a novel one and matches well with our experimental results.

  8. Studies of hydrogen pellet acceleration by electric arc discharge

    Andersen, S.

    1986-01-01

    A preliminary design for an arc heated gas gun is described. The experimental development of the final design constitutes the final phase in contract work for JET. The gun consist of a cryogenic arc chamber connected to the inlet of a gun barrel. With a dose of H 2 -gas condensed in the arc chamber and a D 2 -pellet punch loaded into the barrel the gun is fired by the ignition of an electrical discharge in the arc chamber. The pellet is accelerated by the exhaust of hot H 2 -gas from the arc chamber and its velocity and acceleration is measured by time-of-flight along and outside the barrel. The pressure development by the arc is monitored by pressure transducers as well in the arc chamber as in the barrel. The performance of the gun is described in terms of arc current and voltage versus time as functions of power supply configuration and H 2 propellant dose. The time behaviour of the propellant pressure in the arc chamber and in the barrel is shown in relation to the arc current. Pellet acceleration and pressure development in the gun barrel for the arc heated gas gun is discussed and compared to results obtained by conventional fast valve acceleration

  9. Emitter depletion studies on electrodes of 50 Hz mercury/noble gas discharge lamps during ignition

    Hoek, W.J. van den; Thijssen, T.L.G.; Heijden, A.J.H. van der; Buijsse, B.; Haverlag, M.

    2002-01-01

    The depletion of emitter from the oxide cathodes during the glow switch starting of the discharge in 50 Hz operated low-pressure mercury/noble gas discharge lamps (fluorescent lamps) has been studied. It follows from pulse ignition studies and computer-controlled ignition experiments that two plasma modes exist during ignition: a glow discharge and a vapour-arc discharge. The occurrence of these modes depends on the point of interruption with respect to the phase of the 50 Hz preheat current. The vapour arc appears to be the dominant mechanism of emitter depletion. The average emitter loss per vapour-arc pulse has been quantified by radioactive Ba tracer experiments. The nature of the vapour arc has been studied by fast photography and SEM. The vapour arc involves dielectric breakdown over the non-conducting oxide mass and gives rise to explosive emitter vapourization. (author)

  10. Understanding discharge communication behaviours in a pediatric emergency care context: a mixed methods observation study protocol.

    Curran, Janet A; Bishop, Andrea; Plint, Amy; MacPhee, Shannon; Zemek, Roger; Chorney, Jill; Jabbour, Mona; Porter, Stephen; Sawyer, Scott

    2017-04-17

    One of the most important transitions in the continuum of care for children is discharge to home. Optimal discharge communication between healthcare providers and caregivers (e.g., parents or other guardians) who present to the emergency department (ED) with their children is not well understood. The lack of policies and considerable variation in practice regarding discharge communication in pediatric EDs pose a quality and safety risk for children and their parents. The aim of this mixed methods study is to better understand the process and structure of discharge communication in a pediatric ED context to contribute to the design and development of discharge communication interventions. We will use surveys, administrative data and real-time video observation to characterize discharge communication for six common illness presentations in a pediatric ED: (1) asthma, (2) bronchiolitis, (3) abdominal pain, (4) fever, (5) diarrhea and vomiting, and (6) minor head injury. Participants will be recruited from one of two urban pediatric EDs in Canada. Video recordings will be analyzed using Observer XT. We will use logistic regression to identify potential demographic and visit characteristic cofounders and multivariate logistic regression to examine association between verbal and non-verbal behaviours and parent recall and comprehension. Video recording of discharge communication will provide an opportunity to capture important data such as temporality, sequence and non-verbal behaviours that might influence the communication process. Given the importance of better characterizing discharge communication to identify potential barriers and enablers, we anticipate that the findings from this study will contribute to the development of more effective discharge communication policies and interventions.

  11. Pediatric cardiac surgery Parent Education Discharge Instruction (PEDI) program: a pilot study.

    Staveski, Sandra L; Zhelva, Bistra; Paul, Reena; Conway, Rosalind; Carlson, Anna; Soma, Gouthami; Kools, Susan; Franck, Linda S

    2015-01-01

    In developing countries, more children with complex cardiac defects now receive treatment for their condition. For successful long-term outcomes, children also need skilled care at home after discharge. The Parent Education Discharge Instruction (PEDI) program was developed to educate nurses on the importance of discharge teaching and to provide them with a structured process for conducting parent teaching for home care of children after cardiac surgery. The aim of this pilot study was to generate preliminary data on the feasibility and acceptability of the nurse-led structured discharge program on an Indian pediatric cardiac surgery unit. A pre-/post-design was used. Questionnaires were used to evaluate role acceptability, nurse and parent knowledge of discharge content, and utility of training materials with 40 nurses and 20 parents. Retrospective audits of 50 patient medical records (25 pre and 25 post) were performed to evaluate discharge teaching documentation. Nurses' discharge knowledge increased from a mean of 81% to 96% (P = .001) after participation in the training. Nurses and parents reported high levels of satisfaction with the education materials (3.75-4 on a 4.00-point scale). Evidence of discharge teaching documentation in patient medical records improved from 48% (12 of 25 medical records) to 96% (24 of 25 medical records) six months after the implementation of the PEDI program. The structured nurse-led parent discharge teaching program demonstrated feasibility, acceptability, utility, and sustainability in the cardiac unit. Future studies are needed to examine nurse, parent, child, and organizational outcomes related to this expanded nursing role in resource-constrained environments. © The Author(s) 2014.

  12. Numerical simulation studies of the groundwater discharge to streams from abandoned uranium mill tailings

    Abdul, A.S.; Gillham, R.W.

    1984-06-01

    This report presents an evaluation of the results of simulation studies of groundwater discharge to streams from abandoned uranium mill tailings and the effects of this discharge on the flux of contaminants to surface water systems. In particular, a discussion of the sensitivity of subsurface discharge to specific geometirc, climatic and hydrogeologic factors is presented. Simulations were carried out using a two-dimensional numerical finite-element unsaturated-saturated flow model. A total of twenty-six simulations were made. The first twenty-four of these considered a tailings medium with homogeneous and isotropic hydraulic properties and with textural properties similar to those of sandy geological materials. In addition, two simulations were carried out for tailings materials with hydraulic properties that are similar to those of silt-loam. The results indicated that the actual quantity of subsurface discharge depends on many factors including rainfall rate and duration, surface slope, and texture. However, for the medium-fine sand material, subsurface discharge was always a significant component of the total discharge. Within the context of uranium tailings management this implies that large quantities of contaminants from subsurface sources of medium-textured tailings can be expected to be discharged to streams during stormflow events. Therefore there is reason to suspect that untreated runoff from such tailings will contain significant concentrations of contaminants for long periods of time

  13. Current discharge management of acute coronary syndromes: data from the Rijnmond Collective Cardiology Research (CCR) study.

    Yetgin, T; van der Linden, M M J M; de Vries, A G; Smits, P C; van Mechelen, R; Yap, S C; Boersma, E; Zijlstra, F; van Geuns, R-J M

    2014-01-01

    Medical discharge management of acute coronary syndromes (ACS) remains suboptimal outside randomised trials and constitutes an essential quality benchmark for ACS. We sought to evaluate the rates of key guideline-recommended pharmacological agents after ACS and characteristics associated with optimal treatment at discharge. The Rijnmond Collective Cardiology Research (CCR) registry is an ongoing prospective, observational study in the Netherlands that aims to enrol 4000 patients with ACS. We examined discharge and 1-month follow-up medication use among the first 1000 patients enrolled in the CCR registry. Logistic regression was performed to identify patient and hospital characteristics associated with collective guideline-recommended pharmacotherapy at hospital discharge. At discharge, 94 % of patients received aspirin, 100 % thienopyridines, 80 % angiotensin-converting enzyme inhibitors/angiotensin-II receptor blockers, 87 % β-blockers, 96 % statins, and 65 % the combination of all 5 agents. ST-segment elevation myocardial infarction, hypertension, hypercholesterolaemia, and enrolment in an interventional centre were positive independent predictors of 5-drug combination therapy at discharge. Negative independent predictors were unstable angina and advanced age. Current data from the CCR registry reflect a high quality of care for ACS discharge management in the Rotterdam-Rijnmond region. However, potential still remains for further optimisation.

  14. Influence of operating parameters on surface properties of RF glow discharge oxygen plasma treated TiO{sub 2}/PET film for biomedical application

    Pandiyaraj, K. Navaneetha, E-mail: dr.knpr@gmail.com [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L and T by pass, Chinniyam Palayam (post), Coimbatore 641062 (India); Deshmukh, R.R. [Department of Physics, Institute of Chemical Technology, Matunga, Mumbai 400 019 (India); Mahendiran, R. [Surface Engineering Laboratory, Department of Physics, Sri Shakthi Institute of Engineering and Technology, L and T by pass, Chinniyam Palayam (post), Coimbatore 641062 (India); Su, Pi-G [Department of Chemistry, Chinese Culture University, Taipei 111, Taiwan (China); Yassitepe, Emre; Shah, Ismat [Department of Physics and Astronomy, Department of Materials Science and Engineering, University of Delaware, 208 Dupont Hall, Newark (United States); Perni, Stefano [School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff (United Kingdom); Prokopovich, Polina [School of Pharmacy and Pharmaceutical Sciences, Cardiff University, Cardiff (United Kingdom); Institute of Medical Engineering and Medical Physics, School of Engineering, Cardiff University (United Kingdom); Nadagouda, Mallikarjuna N., E-mail: Nadagouda.Mallikarjuna@epamail.epa.gov [The U.S. Environmental Protection Agency, ORD, NRMRL, WSWRD, 26W. Martin Luther King Drive, Cincinnati, OH 45268 (United States)

    2014-03-01

    In this paper, a thin transparent titania (TiO{sub 2}) film was coated on the surface of flexible poly(ethylene terephthalate) (PET) film using the sol–gel method. The surface properties of the obtained TiO{sub 2}/PET film were further improved by RF glow discharge oxygen plasma as a function of exposure time and discharge power. The changes in hydrophilicity of TiO{sub 2}/PET films were analyzed by contact angle measurements and surface energy. The influence of plasma on the surface of the TiO{sub 2}/PET films was analyzed by atomic force microscopy (AFM) as well as the change in chemical state and composition that were investigated by X-ray photo electron spectroscopy (XPS). The cytotoxicity of the TiO{sub 2}/PET films was analyzed using human osteoblast cells and the bacterial eradication behaviors of TiO{sub 2}/PET films were also evaluated against Staphylococcus bacteria. It was found that the surface roughness and incorporation of oxygen containing polar functional groups of the plasma treated TiO{sub 2}/PET films increased substantially as compared to the untreated one. Moreover the increased concentration of Ti{sup 3+} on the surface of plasma treated TiO{sub 2}/PET films was due to the transformation of chemical states (Ti{sup 4+} → Ti{sup 3+}). These morphological and chemical changes are responsible for enhanced hydrophilicity of the TiO{sub 2}/PET films. Furthermore, the plasma treated TiO{sub 2}/PET film exhibited no citotoxicity against osteoblast cells and antibacterial activity against Staphylococcus bacteria which can find application in manufacturing of biomedical devices. - Graphical abstract: Mechanism of plasma treatment on the surface of TiO{sub 2}/PET films. - Highlights: • Investigated the surface properties of TiO{sub 2}/PET films modified by O{sub 2} plasma • Studied the effect of operating parameters on surface properties of TiO{sub 2}/PET films • Mechanism of the plasma treatment on TiO{sub 2}/PET was clearly investigated.

  15. [Study on formation process of honeycomb pattern in dielectric barrier discharge by optical emission spectrum].

    Dong, Li-Fang; Zhu, Ping; Yang, Jing; Zhang, Yu

    2014-04-01

    The authors report on the first investigation of the variations in the plasma parameters in the formation process of the honeycomb pattern in a dielectric barrier discharge by optical emission spectrum in argon and air mixture. The discharge undergoes hexagonal lattice, concentric spot-ring pattern and honeycomb pattern with the applied voltage increasing. The molecular vibration temperature, electron excitation temperature and electronic density of the three kinds of patterns were investigated by the emission spectra of nitrogen band of second positive system (C3pi(u) --> B3 pi(g)), the relative intensity ratio method of spectral lines of Ar I 763.51 nm (2P(6) --> 1S(5)) and Ar I 772.42 nm (2P(2) -->1S(3)) and the broadening of spectral line 696.5 nm respectively. It was found that the molecular vibration temperature and electron excitation temperature of the honeycomb pattern are higher than those of the hexagonal lattice, but the electron density of the former is lower than that of the latter. The discharge powers of the patterns were also measured with the capacitance method. The discharge power of the honeycomb pattern is much higher than that of the hexagonal lattice. These results are of great importance to the formation mechanism of the patterns in dielectric barrier discharge.

  16. Nonequilibrium phenomena and determination of plasma parameters in the hot core of the cathode region in free-burning arc discharges

    Kuehn, Gerrit; Kock, Manfred

    2007-01-01

    We present spectroscopic measurements of plasma parameters (electron density n e , electron temperature T e , gas temperature T g , underpopulation factor b) in the hot-core region in front of the cathode of a low-current, free-burning arc discharge in argon under atmospheric pressure. The discharge is operated in the hot-core mode, creating a hot cathode region with plasma parameters similar to high-current arcs in spite of the fact that we use comparatively low currents (less than 20 A). We use continuum emission and (optically thin) line emission to determine n e and T e . We apply relaxation measurements based on a power-interruption technique to investigate deviations from local thermodynamic equilibrium (LTE). These measurements let us determine the gas temperature T g . All measurements are performed side-on with charge-coupled-device cameras as detectors, so that all measured plasma parameters are spatially resolved after an Abel inversion. This yields the first ever spatially resolved observation of the non-LTE phenomena of the hot core in the near-cathode region of free-burning arcs. The results only partly coincide with previously published predictions and measurements in the literature

  17. A study of capillary discharge lamps in Ar-Hg and Xe-Hg mixtures

    Denisova, N; Gavare, Z; Revalde, G; Skudra, Ja; Veilande, R

    2011-01-01

    Low-pressure capillary discharge lamps in Ar-Hg and Xe-Hg mixtures are studied. The discharge size is 0.5 mm (500 μm) in radius. According to the literature, such types of plasma sources are classified as microplasmas. The studies include spectrally resolved optical measurements, tomographic reconstructions and numerical simulations using the collisional-radiative model for an Ar-Hg plasma. We discuss the problems of theoretical modelling and experimental diagnostics of microplasma sources. It is shown that the conventional collisional-radiative model, based on the assumption that transportation of atoms in the highly excited states can be neglected, has limitations in modelling a capillary discharge in an Ar-Hg mixture. It is found that diffusion of highly excited mercury atoms to the wall influences the emission properties of the capillary discharge. We have concluded that applications of the emission tomography method to microplasmas require a special analysis in each particular case.

  18. Experimental study of negative corona discharge in pure carbon dioxide and its mixtures with oxygen

    Mikoviny, T; Kocan, M; Matejcik, S; Mason, N J; Skalny, J D

    2004-01-01

    The products of a negative corona discharge in both pure CO 2 and mixtures of CO 2 + O 2 have been studied using a coaxial cylindrical electrode geometry with particular emphasis on the production of ozone. The discharge current in pure CO 2 was found to be highly sensitive to the presence of trace concentrations of molecular oxygen and to changes in the flow speed through the discharge. The effect of dissociative electron attachment to ozone on the discharge current was studied by measurements of ozone and CO production. The ozone concentration increases monotonically with increasing content of oxygen in the mixture with carbon dioxide, whereas the CO concentration exhibits a flat maximum for oxygen concentrations of around 4%. A simple kinetic model of the dominant chemical processes is described and compared with the experimental results

  19. Consideration of radioecological studies in French regulations on the discharges of radioactive effluents

    Hebert, J.

    1980-01-01

    For each of the lines of approach of the regulations on radioactive effluent discharges utilized in France, the report examines the place of radioecology. Developments in greater depth will be devoted to the preliminary and definitive studies foreseen by the conditions of effluent discharges coming from the base nuclear facilities. The place of radioecology in general international law on pollution across national borders or of the sea will also be examined [fr

  20. Study on out-gassing by baking and glow discharge during wall conditioning of vacuum chamber

    Wang Zhiwen; Wei Weixing; Zhao Yuanqing; He Yanhe; Liao Yikui

    2007-01-01

    The model of out-gassing by baking and glow discharge cleaning (GDC) is set up. The properties of them are studied. Out-gassing by baking is from bulk and it obeys the diffusion equation. Out-gassing of glow discharge cleaning is mainly on surface, it is inducement out-gassing by sputtering. Thus the properties of out-gassing for baking and GDC on the HL-1M tokamak are analyzed. Some empirical formulas are given. (authors)

  1. Glow plasma jet - experimental study of a transferred atmospheric pressure glow discharge

    Guerra-Mutis, Marlon H; U, Carlos V Pelaez; H, Rafael Cabanzo

    2003-01-01

    In this paper we present the experimental study of a glow plasma jet (GPJ) obtained from a transferred atmospheric pressure glow discharge (APGD) operating at 60 Hz. The characterization of the emission spectra for both electrical discharges is presented and the electrical circuit features for APGD generation are discussed. The potentiality of GPJ as a source of active species for depletion of contaminants in liquid hydrocarbon fractions is also established

  2. Studies of thermal energy confinement scaling in PDX plasmas: D0 → H+ limiter discharges

    Kaye, S.M.; Goldston, R.J.; Bell, M.

    1984-06-01

    Experiments were performed on the PDX tokamak to study plasma heating and β scaling with higher power, near-perpendicular neutral beam injection. The data taken during these experiments were analyzed using a time-dependent data interpretation code (TRANSP) to study the transport and thermal confinement scaling over a wide range of plasma parameters. This study focuses on results from experiments with D 0 injection into H + plasmas using graphite rail limiters, a = 40 to 44 cm, R = 143 cm, I/sub p/ = 200 to 480 kA, B/sub T/ = 0.7 to 2.2 T, and typically anti n/sub e/ = 2.5 to 4.2 x 10 13 cm -3 . The results of this study indicate that for both ohmic and neutral beam heated discharges the energy flow out of the plasma is dominated by anomalous electron losses, attributed to electron thermal conduction. The ion conduction losses are well described to electron thermal conduction. The ion conduction losses are well described by neoclassical theory; however, the total ion loss influences the power balance significantly only at high toroidal fields and high plasma currents

  3. Fuel cycle parameters for strategy studies

    Archinoff, G.H.

    1979-05-01

    This report summarizes seven fuel cycle parameters (efficiency, specific power, burnup, equilibrium net fissile feed, equilibrium net fissile surplus, first charge fissile content, and whether or not fuel reprocessing is required) to be used in long-term strategy analyses of fuel cycles based on natural UO 2 , low enriched uranium, mixed oxides, plutonium topped thorium, uranium topped thorium, and the fast breeder oxide cycle. (LL)

  4. Study of plasma characteristics in the cathode regime of a nitrogen glow discharge

    Margulis, Alvaro

    1987-01-01

    This research thesis reports the study of the cathode region, cathodic sheath and negative glow, of a nitrogen glow discharge. The author first presents general data regarding glow discharges, a description of the experimental installation, and measurements of discharge balancing. In the next part, he precisely describes spectroscopic methods, and the implementation of diagnoses from an experimental point of view as well as in terms of space resolution. Results are then presented and interpreted. Measurements concern space distributions of excited species, the determination of axial and radial concentrations of nitrogen ions, axial variations of rotational temperatures of the different species and variations of nitrogen ion vibrational temperature. The laser optogalvanic effect on the nitrogen molecular ion is resolved in time, and compared with the result of a theoretical model based on the mobility difference between the different nitrogen ions. Finally, the author compares experimental results on ion profiles along the discharge axis with results obtained with theoretical models [fr

  5. Preoperative study of the surface ECG for the prognosis of atrial fibrillation maze surgery outcome at discharge

    Hernández, Antonio; Rieta, José Joaquín; Alcaraz, Raúl; Hornero, Fernando

    2014-01-01

    The Cox-maze surgery is an effective procedure for terminating atrial fibrillation (AF) in patients requiring open-heart surgery associated with another heart disease. After the intervention, regardless of the patient's rhythm, all are treated with oral anticoagulants and antiarrhythmic drugs prior to discharge. Furthermore, patients maintaining AF before discharge could also be treated with electrical cardioversion (ECV). In view of this, a preoperative prognosis of the patient's rhythm at discharge would be helpful for optimizing drug therapy planning as well as for advancing ECV therapy. This work analyzes 30 preoperative electrocardiograms (ECGs) from patients suffering from AF in order to predict the Cox-maze surgery outcome at discharge. Two different characteristics of the AF pattern have been studied. On the one hand, the atrial activity (AA) organization, which provides information about the number of propagating wavelets in the atria, was investigated. AA organization has been successfully used in previous studies related to spontaneous reversion of paroxysmal AF and to the outcome of ECV. To assess organization, the dominant atrial frequency (DAF) and sample entropy (SampEn) have been computed. On the other hand, the second characteristic studied was the fibrillatory wave (f-wave) amplitude, which has been demonstrated to be a valuable indicator of the Cox-maze surgery outcome in previous studies. Moreover, this parameter has been obtained through a new methodology, based on computing the f-wave average power (fWP). Finally, all the computed indices were combined in a decision tree in order to improve prediction capability. Results for the DAF yielded a sensitivity (Se), a specificity (Sp) and an accuracy (Acc) of 61.54%, 82.35% and 73.33%, respectively. For SampEn the values were 69.23%, 76.00% and 73.33%, respectively, and for fWP they were 92.31%, 82.35% and 86.67%, respectively. Finally, the decision tree combining the three parameters

  6. Chaos in gas discharges

    Piel, A.

    1993-01-01

    Many gas discharges exhibit natural oscillations which undergo a transition from regular to chaotic behavior by changing an experimental parameter or by applying external modulation. Besides several isolated investigations, two classes of discharge phenomena have been studied in more detail: ionization waves in medium pressure discharges and potential relaxation oscillations in filament cathode discharges at very low pressure. The latter phenomenon will be discussed by comparing experimental results from different discharge arrangements with particle-in-cell simulations and with a model based on the van-der-Pol equation. The filament cathode discharge has two stable modes of operation: the low current anode-glow-mode and the high current temperature-limited-mode, which form the hysteresis curve in the I(U) characteristics. Close to the hysteresis point of the AGM periodic relaxation oscillations occur. The authors demonstrate that the AGM can be understood by ion production in the anode layer, stopping of ions by charge exchange, and trapping in the virtual cathode around the filament. The relaxation oscillations consist of a slow filling phase and a rapid phase that invokes formation of an unstable double-layer, current-spiking, and ion depletion from the cathodic plasma. The relaxation oscillations can be mode-locked by external modulation. Inside a mode-locked state, a period doubling cascade is observed at high modulation degree

  7. Studies of low current back-discharge in point-plane geometry with dielectric layer

    Jaworek, A.; Rajch, E.; Czech, T.; Lackowski, M

    2005-01-01

    The paper presents results of spectroscopic investigations of back-discharge generated in the point-plane electrode geometry in air at atmospheric pressure, with the plane covered with fly ash layer. Four forms of the discharges were studied: onset streamers, glow, breakdown streamers and low-current back-arc discharge. Both polarities of the active discharge electrode, positive and negative, were tested. The back discharge is a type of DC electrical discharge, which take place when the passive plane electrode is covered with a dielectric layer. The layer can be made of solid material or a packed bed of dust or powder of low conductivity. The charge produced due to ionisation processes in the vicinity of the active point electrode is accumulated on the dielectric surface, and generates high electric field through this layer. When critical electric field through the layer is attained an electrical breakdown of the layer take place. The point of breakdown becomes a new source of ions of polarity opposite to those generated by the active electrode. The dielectric layer on the passive electrode causes that gaseous discharges such as breakdown streamers or arc start at lower voltages than they could in the case of normal corona discharge. The visual forms of the discharge were recorded and correlated with the current-voltage characteristics and optical emission spectra. Emission spectra of the discharge were measured in the light wavelength range of 200 to 600 nm to get information about excitation and ionisation processes. The light spectra were analysed by monochromator SPM-2 Karl-Zeiss-Jena with diffraction grating of 1302 grooves/mm and photomultiplier R375 (Hamamatsu) and signal preamplifier unit C7319 (Hamamatsu). The spectral analysis showed that the nitrogen molecular bands were dominant, but the emission of negative ions from the dielectric layer material were also detected. The most noticeable light emission in the range from 280 to 490 nm due to second

  8. Studies on water quality parameters due to operation of PHWR at KAPS

    Jha, Mukesh; John, Jaison T.; Joshi, C.P.; Vyas, P.V.; Hegde, A.G.

    2005-01-01

    The paper elucidates the effect of water quality due to operation of Pressurised Heavy Water Reactor located at Kakrapar as water is the essential commodity for all living beings. It is the main concern in recent times for environmental protection, there is a pressure on all type of industries including nuclear power stations to discharge various types of effluents in such a manner that pollution in surrounding environment is kept to the minimum. Owing the wastewater discharge modes of Kakrapar atomic power station behavior of effluents resulting impact on environment and general public will be guided by the water quality of the aquatic system. To ensure the quality of water, the study of water quality parameters are taken up and the investigated parameters showed no degradation in ecosystem due to the operation of PHWR at KAPS. (author)

  9. Appropriate and inappropriate influences on outpatient discharge decision making in dermatology: a prospective qualitative study.

    Harun, N A; Finlay, A Y; Salek, M S; Piguet, V

    2015-09-01

    Outpatient discharge decision making in dermatology is poorly understood. To identify the influences on clinicians' thought processes when making discharge decisions in dermatology outpatient clinics. Forty clinicians from 11 National Health Service Trusts in England were interviewed. The interviews were audiorecorded, transcribed, coded and thematically analysed. The mean age of the clinicians was 48.8 years (range 33.0-67.0), 17 (43%) were men and 19 (48%) had > 20 years of clinical experience. One hundred and forty-eight influences were reported, with five main themes: (i) disease-based influences included type of diagnosis (100% of clinicians), guidelines (100%) and treatment needed (100%); (ii) clinician-based influences included the clinician's level of experience (100%), seniority (37%), emotional attitude (95%), 'gut feeling' (25%), personal attitude towards discharge (45%) and level of perception (100%); (iii) patient-based influences included patients' ability to cope with their disease (100%), wishes (70%), quality of life (32%), command of English (40%) and cultural background (25%); (iv) practice-based influences included good primary care (100%), secondary support structure (100%) and clinic capacity pressure (67%); (v) policy-based influences included pressure from hospital managers (57%) and an active discharge policy (7%). Fourteen (9%) influences were potentially inappropriate. This study has identified multiple factors influencing outpatient discharge decision making. This provides the basis for developing evidence-based training to improve discharge decision appropriateness. © 2015 British Association of Dermatologists.

  10. Theoretical study on flow-induced vibration of a cylindrical weir due to fluid discharge

    Fujita, Katsuhisa; Ito, Tomohiro; Hirota, Kazuo; Kodama, Tetsuhiko

    1994-01-01

    In a FBR, the inside of the reactor vessel is cooled by liquid sodium. Liquid sodium is supplied to the upper plenum from its bottom and discharges over the top of the cylindrical weir down to the lower plenum. The weir is so thin in order to decrease the thermal stress on it that the fluid--structure interaction becomes predominant. A fluidelastic vibration of the weir due to fluid discharge was discovered in a French FBR. In this study, a theoretical model was developed on the ''fluid--elastic mode'' instability of a cylindrical weir due to fluid discharge from the upper plenum to the lower plenum. In the analysis, the fluctuation of both the discharge flow rate over a weir due to the vibration of the cylindrical shell and the pressure in the lower plenum due to fluid discharge were formulated. Instability criteria was derived from the added damping ratio due to fluid discharge using modal analysis. The natural modes and modal mass of the weir were obtained by the analysis using the FEM code taking the fluid - structure interaction into consideration. The theoretical instability range in terms of the fall height and the flow rate is compared with the experimental results. The theoretical values showed a good agreement with the experimental ones

  11. Gas-discharge sources with charged particle emission from the plasma of glow discharge with a hollow cathode

    Semenov, A P

    2001-01-01

    One studied properties of a magnetron discharge with a cold hollow and uncooled rod cathodes. One demonstrated the dominant effect of thermoelectron emission of a rod cathode heated in a discharge on characteristics of discharge and on emission properties of a gas-discharge plasma and the possibility pf a smooth transition of glow discharge to diffusion mode of arc discharge combustion. Paper describes sources of ions and electrons with improved physical and generalized design and engineering parameters. One shows the promise of the electrode structure of a hollow cathode magnetron discharge to be used as a source, in particular, of the atomic hydrogen and of atom flow of a working rod cathode

  12. Study of spatiotemporal dynamics of a nanosecond atmospheric-pressure dielectric barrier discharge in millimeter-long air gaps

    Malashin, M. V.; Moshkunkov, S. I.; Khomich, V. Yu.; Shershunova, E. A., E-mail: eshershunova@gmail.com [Russian Academy of Sciences, Institute for Electrophysics and Electric Power (Russian Federation)

    2017-02-15

    The spatiotemporal dynamics of a nanosecond atmospheric-pressure dielectric barrier discharge in 1- to 3-mm-long air gaps was studied experimentally. By using a segmented electrode, data on the time evolution of the discharge in different regions of the discharge gap were obtained. The uniformity of the discharge over the cross section is estimated by analyzing the spatial distribution of its glow.

  13. Study on effect of tool electrodes on surface finish during electrical discharge machining of Nitinol

    Sahu, Anshuman Kumar; Chatterjee, Suman; Nayak, Praveen Kumar; Sankar Mahapatra, Siba

    2018-03-01

    Electrical discharge machining (EDM) is a non-traditional machining process which is widely used in machining of difficult-to-machine materials. EDM process can produce complex and intrinsic shaped component made of difficult-to-machine materials, largely applied in aerospace, biomedical, die and mold making industries. To meet the required applications, the EDMed components need to possess high accuracy and excellent surface finish. In this work, EDM process is performed using Nitinol as work piece material and AlSiMg prepared by selective laser sintering (SLS) as tool electrode along with conventional copper and graphite electrodes. The SLS is a rapid prototyping (RP) method to produce complex metallic parts by additive manufacturing (AM) process. Experiments have been carried out varying different process parameters like open circuit voltage (V), discharge current (Ip), duty cycle (τ), pulse-on-time (Ton) and tool material. The surface roughness parameter like average roughness (Ra), maximum height of the profile (Rt) and average height of the profile (Rz) are measured using surface roughness measuring instrument (Talysurf). To reduce the number of experiments, design of experiment (DOE) approach like Taguchi’s L27 orthogonal array has been chosen. The surface properties of the EDM specimen are optimized by desirability function approach and the best parametric setting is reported for the EDM process. Type of tool happens to be the most significant parameter followed by interaction of tool type and duty cycle, duty cycle, discharge current and voltage. Better surface finish of EDMed specimen can be obtained with low value of voltage (V), discharge current (Ip), duty cycle (τ) and pulse on time (Ton) along with the use of AlSiMg RP electrode.

  14. The effects of design parameters on the charge-discharge performance of iron-chromium redox flow batteries

    Zeng, Y.K.; Zhao, T.S.; Zhou, X.L.; Zeng, L.; Wei, L.

    2016-01-01

    Highlights: • The effects of design parameters on the ICRFB performance are investigated. • The energy efficiency of the present ICRFB reaches 80.5% at 480 mA cm"−"2. • The power density reaches 1077 and 694 mW cm"−"2 at 65 and 25 °C, respectively. • The dominant loss of ICRFBs operating at 25 and 65 °C is the ohmic loss. - Abstract: The objective of this work is to understand and identify key design parameters that influence the battery performance of iron-chromium redox flow batteries (ICRFBs). The investigated parameters include the membrane thickness, electrode compression ratio, electrode pretreatment and catalyst loading. Results show that: (i) with a thin NR-211 membrane and a high electrode compression ratio of 62.5%, the operating current density of the ICRFB can reach as high as 480 mA cm"−"2 at an energy efficiency of higher than 80%; (ii) the bismuth catalyst loading has insignificant effect on the battery performance in the range of 0.52–10.45 mg cm"−"2; (iii) the moderately oxidative thermal pretreatment of the electrode improves the energy efficiency compared to the as-received electrode while the electrode prepared with a harsh pretreatment deteriorates the battery performance; and (iv) for the present ICRFBs operating at both 25 °C and 65 °C, the dominant loss is identified to be ohmic loss rather than kinetics loss.

  15. Experimental study on thermal characteristics of positive leader discharges using Mach-Zehnder interferometry

    Zhou, X.; Zeng, R.; Zhuang, C.; Chen, S.

    2015-01-01

    Leader discharge is one of the main phases in long air gap breakdown, which is characterized by high temperature and high conductivity. It is of great importance to determine thermal characteristics of leader discharges. In this paper, a long-optical-path Mach-Zehnder interferometer was set up to measure the thermal parameters (thermal diameter, gas density, and gas temperature) of positive leader discharges in atmospheric air. IEC standard positive switching impulse voltages were applied to a near-one-meter point-plane air gap. Filamentary channels with high gas temperature and low density corresponding to leader discharges were observed as significant distortions in the interference fringe images. Typical diameters of the entire heated channel range from 1.5 mm to 3.5 mm with an average expansion velocity of 6.7 m/s. In contrast, typical diameters of the intensely heated region with a sharp gas density reduction range from 0.4 mm to 1.1 mm, about one third of the entire heated channel. The radial distribution of the gas density is calculated from the fringe displacements by performing an Abel inverse transform. The typical calculated gas density reduction in the center of a propagating leader channel is 80% to 90%, corresponding to a gas temperature of 1500 K to 3000 K based on the ideal gas law. Leaders tend to terminate if the central temperature is below 1500 K

  16. Experimental study on thermal characteristics of positive leader discharges using Mach-Zehnder interferometry

    Zhou, X., E-mail: zhouxuan12@mails.thu.edu.cn; Zeng, R.; Zhuang, C.; Chen, S. [Department of Electrical Engineering, Tsinghua University, Beijing 100084 (China)

    2015-06-15

    Leader discharge is one of the main phases in long air gap breakdown, which is characterized by high temperature and high conductivity. It is of great importance to determine thermal characteristics of leader discharges. In this paper, a long-optical-path Mach-Zehnder interferometer was set up to measure the thermal parameters (thermal diameter, gas density, and gas temperature) of positive leader discharges in atmospheric air. IEC standard positive switching impulse voltages were applied to a near-one-meter point-plane air gap. Filamentary channels with high gas temperature and low density corresponding to leader discharges were observed as significant distortions in the interference fringe images. Typical diameters of the entire heated channel range from 1.5 mm to 3.5 mm with an average expansion velocity of 6.7 m/s. In contrast, typical diameters of the intensely heated region with a sharp gas density reduction range from 0.4 mm to 1.1 mm, about one third of the entire heated channel. The radial distribution of the gas density is calculated from the fringe displacements by performing an Abel inverse transform. The typical calculated gas density reduction in the center of a propagating leader channel is 80% to 90%, corresponding to a gas temperature of 1500 K to 3000 K based on the ideal gas law. Leaders tend to terminate if the central temperature is below 1500 K.

  17. Parametric study of ohmic discharges in the TCA tokamak

    De Chambrier, A.; Collins, G.A.; Heym, A.; Hofmann, F.; Hollenstein, Ch.; Joye, B.; Keller, R.; Lietti, A.; Lister, J.B.; Moret, J.-M.; Nowak, S.; O'Rourke, J.; Pochelon, A.; Simm, W.

    1983-01-01

    The study of the energy confinement in a tokamak is an important aspect in the characterisation of its performance. The TCA tokamak has been in operation now for more than two years and the state of the machine and of its diagnostics have permitted such work to be performed. The authors describe the proper method for this type of approach and then present the results concerning the energy confinement of the electrons and ions. (Auth./G.T.H.)

  18. Study and analysis of drift chamber parameters

    Martinez Laso, L.

    1988-01-01

    The present work deals mainly with drift chambers. In the first chapter a summary of drift chamber properties is presented. The information has been collected from the extensive bibliography available in this field. A very simple calculation procedure of drift chamber parameters has been developed and is presented in detail in the second chapter. Some prototypes have been made following two geometries (multidrift chamber and Z-chambers). Several installations have been used for test and calibration of these prototypes. A complete description of these installations is given in the third chapter. Cosmic rays, beta particles from a Ru106 radiactive source and a test beam in the WA (West Area) of SPS at CERN have been used for experimental purposes. The analysis and the results are described for the different setups. The experimental measurements have been used to produce a complete cell parametrization (position as function of drift time) and to obtain spatial resolution values (in the range of 200-250 um). Experimental results are in good agreement with numerical calculations. (Author)

  19. Influence of various parameters on the calculation of the population exposure due to discharge of radioactive matter into the atmosphere

    Schmidtlein, P.

    1980-01-01

    The evaluation of the influences of the examined parameters on the calculation of the dose rate shows that a new concept for determination of the radiation exposure in the surroundings of nuclear facilities is required. A computing formalism based on theoretical considerations determines the effective activity absorbed and, after combination with dose rate factors, the effective dose rate per year. It is of great importance to verify the validity of the still incomplete input data for determination of the dose factors of the age groups 'infants' and 'children' and to prepare new data records. (DG) [de

  20. Study of the equilibrium of a multi-polar discharge

    Gauthereau, Christian

    1983-01-01

    As previous studies showed that the increase of electronic density in plasmas is not due to plasma confinement which is rather poor, but to the confinement of primary electrons, this research thesis addresses the issue of uniformity of multi-polar plasmas. The author first shows that noticed density profiles can be explained if the ionisation term is assumed to be non uniform and to be strongly increasing at the vicinity of walls where the magnetic field governs. Trajectories of primary electrons in the multi-polar field are studied. Then, the author shows that the increase of the ionisation term at the vicinity of walls is related to the existence of an important population of primary electrons trapped in the magnetic field. A similar situation is indeed noticed near the Earth where Van Allen belts are made of particles emitted by the Sun and trapped by the bipolar Earth magnetic field. The problem of particle trapping by the multi-polar field is then addressed, and a trapping mechanism is proposed. Finally, some experimental results show the existence of trapped particles and the instability [fr

  1. Improving discharge care: the potential of a new organisational intervention to improve discharge after hospitalisation for acute stroke, a controlled before-after pilot study.

    Cadilhac, Dominique A; Andrew, Nadine E; Stroil Salama, Enna; Hill, Kelvin; Middleton, Sandy; Horton, Eleanor; Meade, Ian; Kuhle, Sarah; Nelson, Mark R; Grimley, Rohan

    2017-08-04

    Provision of a discharge care plan and prevention therapies is often suboptimal. Our objective was to design and pilot test an interdisciplinary, organisational intervention to improve discharge care using stroke as the case study using a mixed-methods, controlled before-after observational study design. Acute care public hospitals in Queensland, Australia (n=15). The 15 hospitals were ranked against a benchmark based on a composite outcome of three discharge care processes. Clinicians from a 'top-ranked' hospital participated in a focus group to elicit their success factors. Two pilot hospitals then participated in the organisational intervention that was designed with experts and consumers. Hospital clinicians involved in discharge care for stroke and patients admitted with acute stroke or transient ischaemic attack. A four-stage, multifaceted organisational intervention that included data reviews, education and facilitated action planning. Three discharge processes collected in Queensland hospitals within the Australian Stroke Clinical Registry were used to select study hospitals: (1) discharge care plan; (2) antihypertensive medication prescription and (3) antiplatelet medication prescription (ischaemic events only). Primary measure: composite outcome. Secondary measures: individual adherence changes for each discharge process; sensitivity analyses. The performance outcomes were compared 3 months before the intervention (preintervention), 3 months postintervention and at 12 months (sustainability). Data from 1289 episodes of care from the two pilot hospitals were analysed. Improvements from preintervention adherence were: antiplatelet therapy (88%vs96%, p=0.02); antihypertensive prescription (61%vs79%, porganisational intervention. The intervention warrants further application and trialling on a larger scale. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is

  2. Nutrition Care after Discharge from Hospital: An Exploratory Analysis from the More-2-Eat Study

    Celia Laur

    2018-01-01

    Full Text Available Many patients leave hospital in poor nutritional states, yet little is known about the post-discharge nutrition care in which patients are engaged. This study describes the nutrition-care activities 30-days post-discharge reported by patients and what covariates are associated with these activities. Quasi-randomly selected patients recruited from 5 medical units across Canada (n = 513 consented to 30-days post-discharge data collection with 48.5% (n = 249 completing the telephone interview. Use of nutrition care post-discharge was reported and bivariate analysis completed with relevant covariates for the two most frequently reported activities, following recommendations post-discharge or use of oral nutritional supplements (ONS. A total of 42% (n = 110 received nutrition recommendations at hospital discharge, with 65% (n = 71/110 of these participants following those recommendations; 26.5% (n = 66 were taking ONS after hospitalization. Participants who followed recommendations were more likely to report following a special diet (p = 0.002, different from before their hospitalization (p = 0.008, compared to those who received recommendations, but reported not following them. Patients taking ONS were more likely to be at nutrition risk (p < 0.0001, malnourished (p = 0.0006, taking ONS in hospital (p = 0.01, had a lower HGS (p = 0.0013; males only, and less likely to believe they were eating enough to meet their body’s needs (p = 0.005. This analysis provides new insights on nutrition-care post-discharge.

  3. Patient input into the development and enhancement of ED discharge instructions: a focus group study.

    Buckley, Barbara A; McCarthy, Danielle M; Forth, Victoria E; Tanabe, Paula; Schmidt, Michael J; Adams, James G; Engel, Kirsten G

    2013-11-01

    Previous research indicates that patients have difficulty understanding ED discharge instructions; these findings have important implications for adherence and outcomes. The objective of this study was to obtain direct patient input to inform specific revisions to discharge documents created through a literacy-guided approach and to identify common themes within patient feedback that can serve as a framework for the creation of discharge documents in the future. Based on extensive literature review and input from ED providers, subspecialists, and health literacy and communication experts, discharge instructions were created for 5 common ED diagnoses. Participants were recruited from a federally qualified health center to participate in a series of 5 focus group sessions. Demographic information was obtained and a Rapid Estimate of Adult Literacy in Medicine (REALM) assessment was performed. During each of the 1-hour focus group sessions, participants reviewed discharge instructions for 1 of 5 diagnoses. Participants were asked to provide input into the content, organization, and presentation of the documents. Using qualitative techniques, latent and manifest content analysis was performed to code for emergent themes across all 5 diagnoses. Fifty-seven percent of participants were female and the average age was 32 years. The average REALM score was 57.3. Through qualitative analysis, 8 emergent themes were identified from the focus groups. Patient input provides meaningful guidance in the development of diagnosis-specific discharge instructions. Several themes and patterns were identified, with broad significance for the design of ED discharge instructions. Copyright © 2013 Emergency Nurses Association. Published by Mosby, Inc. All rights reserved.

  4. Study of discharges produced by surface waves under medium and high pressure: application to chemical analysis

    Laye epouse Granier, Agnes

    1986-01-01

    This report deals with the study of microwave discharges produced in argon gas by surface waves in the 20-760 Torr pressure range. Application to chemical analysis by emission optical spectroscopy is also investigated. First of all we study the propagation of a surface wave in a bounded plasma in which the effective collision frequency for momentum transfer ν is higher than the excitation one. The axial electron density profile is determined from two diagnostic techniques, i.e., phase variations of the wave field and Stark broadening of H β line. Then we deduce the discharge characteristics ν, θ (maintaining power of an electron-ion pair) and E eff (effective electric field for discharge sustaining) from the electron density profile. Then an energy balance of the discharge is developed. It explains the change of operating conditions in the 20-50 Torr range. At low pressure the discharge is governed by ambipolar diffusion whereas at high pressure, the electrons are mainly lost by volume recombination of Ar 2 + . Finally, we report on chemical analysis experiment of gases (optimum sensibility in found near 100 Torr) and of metallic solutions sprayed by a graphite oven. Performances of such a design and ICP plasma torches are compared. (author) [fr

  5. Breakdown transient study of plasma distributions in a 2.45 GHz hydrogen discharge

    Cortázar, O.D., E-mail: daniel.cortazar@uclm.es [Universidad de Castilla-La Mancha, ETSII-INEI, Applied Mechanics and Projects Department, C.J. Cela s/n, 13170 Ciudad Real (Spain); Megía-Macías, A. [ESS Bilbao Consortium, Polígono Ugaldeguren-III Pol. A 7B, 48170-Zamudio, Vizcaya (Spain); Tarvainen, O.; Koivisto, H. [University of Jyväskylä, Department of Physics, PO Box 35 (YFL), 40500 Jyväskylä (Finland)

    2015-05-01

    Plasma distribution transients associated with the breakdown of a 2.45 GHz hydrogen discharge similar to high current microwave ion sources are studied by means of an ultra-fast frame image acquisition system in visible light range. Eight different plasma distributions have been studied by photographing the 2D projections of the discharge through a transparent plasma electrode. The temporal evolution of images in Balmer-alpha and Fulcher band wavelengths have been recorded associated to atomic and molecular excitation and ionization processes. Some unexpected plasma distributions transient behaviors during breakdown are reported.

  6. Multi-parameter study of gammas capture

    Samama, R.; Nifenecker, H.; Carlos, P.; Delaitre, B.

    1966-06-01

    This equipment is intended for analyzing, recording, and reading simultaneous information from several 'gamma' detectors. It allows multiparameter study of γ-γ cascades emitted after thermal neutrons capture. (authors) [fr

  7. Expansion of a nitrogen discharge by sound

    Antinyan, M.A.; Galechyan, G.A.; Tavakalyan, L.B.

    1992-01-01

    When the background pressure and the discharge current in a gas discharge are raised the plasma column is tightened up into a filament. Then the discharge occupies a region of the discharge tube whose transverse dimensions are substantially less than those of the tube. This contraction phenomenon in discharges restricts the range of parameters used in various devices to the range of relatively low discharge currents and low gas pressures. This contraction interferes with creating high-power gas lasers, since it acts destructively on the lasing process. In order to suppress filamentation of discharges the working gas has been pumped through the system at high speed, with considerable success. The turbulent mixing in the stream plays an important role in creating an uncontracted discharge at high pressures. The purpose of the present work is to study the possibility of undoing the contraction of a nitrogen discharge, which is one of the main components in the operation of a CO 2 laser, by introducing an intense sound wave in the discharge tube. Discharge contraction and the effect of a sound wave propagating along the plasma column have been investigated experimentally in nitrogen by studying the current-voltage characteristics of a contracted discharge. 6 refs., 3 figs

  8. Assessing the impact of the introduction of an electronic hospital discharge system on the completeness and timeliness of discharge communication: a before and after study.

    Mehta, Rajnikant L; Baxendale, Bryn; Roth, Katie; Caswell, Victoria; Le Jeune, Ivan; Hawkins, Jack; Zedan, Haya; Avery, Anthony J

    2017-09-05

    Hospital discharge summaries are a key communication tool ensuring continuity of care between primary and secondary care. Incomplete or untimely communication of information increases risk of hospital readmission and associated complications. The aim of this study was to evaluate whether the introduction of a new electronic discharge system (NewEDS) was associated with improvements in the completeness and timeliness of discharge information, in Nottingham University Hospitals NHS Trust, England. A before and after longitudinal study design was used. Data were collected using the gold standard auditing tool from the Royal College of Physicians (RCP). This tool contains a checklist of 57 items grouped into seven categories, 28 of which are classified as mandatory by RCP. Percentage completeness (out of the 28 mandatory items) was considered to be the primary outcome measure. Data from 773 patients discharged directly from the acute medical unit over eight-week long time periods (four before and four after the change to the NewEDS) from August 2010 to May 2012 were extracted and evaluated. Results were summarised by effect size on completeness before and after changeover to NewEDS respectively. The primary outcome variable was represented with percentage of completeness score and a non-parametric technique was used to compare pre-NewEDS and post-NewEDS scores. The changeover to the NewEDS resulted in an increased completeness of discharge summaries from 60.7% to 75.0% (p communication.

  9. Measurement Techniques Used for Study of Electrical Discharge Mechanisms in Insulating Ester Fluids under Lightning Impulse

    ROZGA, P.

    2014-08-01

    Full Text Available This article describes the measurement techniques used for the study of mechanisms of electrical discharge development in ester fluids under lightning impulse voltage. These techniques were applied in a laboratory experimental system which enabled the acquisition of a wide range of experimental data. An analysis of the data gives the possibility of assessing the processes responsible for electrical discharge propagation in different types of dielectric liquids. The photographic registration system provides photographs of developing discharges. This uses the shadowgraph method with an impulse laser as a flash lamp. The system of light emission registration enables collection of the time courses of light emitted by the developing discharge. Both systems operating together are synchronized using light guide communication. They are also unaffected by external disturbances such as network overvoltages and high electrical field stress. Preliminary results obtained on the basis of the described techniques, in the field of electrical discharge development in synthetic and natural esters, are presented in the article. These results confirm suitability of the methods used and give the possibility to formulate first conclusions.

  10. Numerical study on xenon positive column discharges of mercury-free lamp

    Ouyang, Jiting; He, Feng; Miao, Jinsong; Wang, Jianqi; Hu, Wenbo

    2007-01-01

    In this paper, the numerical study has been performed on the xenon positive column discharges of mercury-free fluorescent lamp. The plasma discharge characteristics are analyzed by numerical simulation based on two-dimensional fluid model. The effects of cell geometry, such as the dielectric layer, the electrode width, the electrode gap, and the cell height, and the filling gas including the pressure and the xenon percentage are investigated in terms of discharge current and discharge efficiency. The results show that a long transient positive column will form in the xenon lamp when applying ac sinusoidal power and the lamp can operate in a large range of voltage and frequency. The front dielectric layer of the cell plays an important role in the xenon lamp while the back layer has little effect. The ratio of electrode gap to cell height should be large to achieve a long positive column xenon lamp and higher efficiency. Increase of pressure or xenon concentration results in an increase of discharge efficiency and voltage. The discussions will be helpful for the design of commercial xenon lamp cells

  11. [Study on the Emission Spectrum of Hydrogen Production with Microwave Discharge Plasma in Ethanol Solution].

    Sun, Bing; Wang, Bo; Zhu, Xiao-mei; Yan, Zhi-yu; Liu, Yong-jun; Liu, Hui

    2016-03-01

    Hydrogen is regarded as a kind of clean energy with high caloricity and non-pollution, which has been studied by many experts and scholars home and abroad. Microwave discharge plasma shows light future in the area of hydrogen production from ethanol solution, providing a new way to produce hydrogen. In order to further improve the technology and analyze the mechanism of hydrogen production with microwave discharge in liquid, emission spectrum of hydrogen production by microwave discharge plasma in ethanol solution was being studied. In this paper, plasma was generated on the top of electrode by 2.45 GHz microwave, and the spectral characteristics of hydrogen production from ethanol by microwave discharge in liquid were being studied using emission spectrometer. The results showed that a large number of H, O, OH, CH, C2 and other active particles could be produced in the process of hydrogen production from ethanol by microwave discharge in liquid. The emission spectrum intensity of OH, H, O radicals generated from ethanol is far more than that generated from pure water. Bond of O-H split by more high-energy particles from water molecule was more difficult than that from ethanol molecule, so in the process of hydrogen production by microwave discharge plasma in ethanol solution; the main source of hydrogen was the dehydrogenation and restructuring of ethanol molecules instead of water decomposition. Under the definite external pressure and temperature, the emission spectrum intensity of OH, H, O radicals increased with the increase of microwave power markedly, but the emission spectrum intensity of CH, C2 active particles had the tendency to decrease with the increase of microwave power. It indicated that the number of high energy electrons and active particles high energy electron energy increased as the increase of microwave power, so more CH, C2 active particles were split more thoroughly.

  12. Study to Evaluate Targeted Management and Syndromic Management in Women Presenting with Abnormal Vaginal Discharge.

    Meena, Veena; Bansal, Charu Lata

    2016-10-01

    Vaginal discharge is a commonest complaint among women in reproductive age group. Infective vaginal discharge can be broadly categorized into vaginitis or mucopurulent cervicitis. Vaginitis is predominantly caused by bacterial vaginosis, vaginal candidiasis, vaginal trichomoniasis, etc. Mucopurulent cervicitis is due to chlamydia or gonococcal infection. The targeted management is based on identification of causative organism and targeting the therapy against it, while syndromic management is based on high risk factors's presence. To study the effect of targeted management as compared to syndromic management in achieving a complete cure for abnormal vaginal discharge and to study the microbial flora of women presenting with abnormal vaginal discharge. The study is a randomized control trial conducted at tertiary health care on 200 women who presented with abnormal vaginal discharge, distributed in two groups A and B each consisted of 100 women. Group A underwent laboratory investigations, and treatment was started as soon as reports were available. Group B was given syndromic management based on high risk factors's presence. Both groups were followed up after 2 weeks. The prevalence of various organisms in vaginal discharge was candidiasis 39 %, bacterial vaginosis 28 %, trichomoniasis 5 %, N. gonorrhoeae 5 % and chlamydia 2 % among the 100 women in group A. Response to treatment for vaginitis was 76.3 % in group A, whereas it was 41 % in group B. With cervicitis, 71.4 % women responded to treatment in targeted group as compared to 54 % in syndromic management group. There is a potential disadvantage of syndromic management because of its total reliability on a subjective clinical assessment.

  13. The effect of axial ion parameters on the properties of glow discharge polymer in T2B/H2 plasma

    Ai, Xing; He, Xiao-Shan; Huang, Jing-Lin; He, Zhi-Bing; Du, Kai; Chen, Guo

    2018-03-01

    Glow discharge polymer (GDP) films were fabricated using plasma-enhanced chemical vapor deposition. The main purpose of this work was to explore the correlations of plasma parameters with the surface morphology and chemical structure of GDP films. The intensities of main positive ions and ion energy as functions of axial distances in T2B/H2 plasma were diagnosed using energy-resolved mass spectrometry. The surface morphology and chemical structure were characterized as functions of axial distances using a scanning electron microscope and Fourier transform infrared spectroscopy, respectively. As the axial distance increases, both the intensities of positive ions and high energy ions decreases, and dissociation weakens while polymerization enhances. This leads to the weakening of the cross-linking structure of GDP films and the formation of dome defects on films. Additionally, high energy ions could introduce a strong etching effect to form etching pits. Therefore, an axial distance of about 20 mm was found to be the optimal plasma parameter to prepare the defect-free GDP films. These results could help one to find the optimal plasma parameters for GDP film deposition.

  14. Simulation study of the discharge characteristics of silos with cohesive particles

    Hund, David; Weis, Dominik; Hesse, Robert; Antonyuk, Sergiy

    2017-06-01

    In many industrial applications the silo for bulk materials is an important part of an overall process. Silos are used for instance to buffer intermediate products to ensure a continuous supply for the next process step. This study deals with the discharging behaviour of silos containing cohesive bulk solids with particle sizes in the range of 100-500 μm. In this contribution the TOMAS [1,2] model developed for stationary and non-stationary discharging of a convergent hopper is verified with experiments and simulations using the Discrete Element Method. Moreover the influence of the cohesion of the bulk solids on the discharge behaviour is analysed by the simulation. The simulation results showed a qualitative agreement with the analytical model of TOMAS.

  15. Post-discharge symptoms following fast-track colonic cancer surgery: a phenomenological hermeneutic study

    Krogsgaard, Marianne; Dreyer, Pia; Egerod, Ingrid

    2014-01-01

    OBJECTIVE: To obtain knowledge of patients' experiences of postoperative symptoms during the initial two weeks following fast-track colonic cancer surgery. METHOD: Semi-structured in-depth interviews with seven colonic cancer patients two weeks post hospital discharge. Analysis was performed using...... a phenomenological hermeneutical approach. RESULTS: During the first two weeks after discharge the patients experienced unfamiliar symptoms that affected their everyday lives. Despite distressing symptoms, they applied a "wait-and-see" strategy, and only reacted when symptoms became intolerable. The patients failed...... to shorter hospitalisation and improved physical performance, post-colonic surgery patients experience various symptoms after discharge. Healthcare professionals need to address symptoms that might have immediate and long-term consequences on patients' everyday life. Follow-up studies are encouraged...

  16. Study for discharge coefficient of flow nozzles. Prediction by using numerical simulation

    Ikeda, Hiroshi; Sakai, Norio; Yamamoto, Yasushi; Arai, Kenji; Matsumoto, Masaaki

    2008-01-01

    In nuclear plant, as water feeding into reactor have much effect on thermal power of plant, it is important to measure accurately the flow rate of water. Flow nozzle is on of typical differential pressure type flow meters and the discharge coefficient is used to calculate the flow rate. This coefficient is given by actual experiment and theory. We studied the theoretical assumption of the discharge coefficient curve using numerical simulation and evaluated the effect of flow nozzle configuration on the coefficient numerically and experimentally. As the result, numerical simulation can predict the discharge coefficient of theoretical curve within 0.3%. And we found that the throat length and throat tapping location of flow nozzle have much effect on the coefficient. (author)

  17. Turning Over Patient Turnover: An Ethnographic Study of Admissions, Discharges, and Transfers

    Mowinski Jennings, Bonnie; Sandelowski, Margarete; Boshamer, Cary C.; Higgins, Melinda K.

    2014-01-01

    The impact on nursing work of patient turnover (admissions, discharges, and transfers) became evident in an ethnographic study of turbulence. The patient turnover data were generated from extensive observations, 21 formal interviews, and a year of admission and discharge records on one medical and one surgical unit. Timing of turnover events on the two units differed, but on both units admissions typically interrupted workflow more than did discharges, clustered admissions were more disruptive than staggered admissions, and patient turnover during change of shift was more disruptive than during medication administration. Understanding the complexity of patient turnover will elucidate the work involved and improve the evidence base for nurse staffing, a key determinant of quality and safety of care. PMID:24242196

  18. Experimental studies of the overshoot and undershoot in pulse-modulated radio-frequency atmospheric discharge

    Huo, W. G.; Li, R. M.; Shi, J. J. [School of Physics and Electronic Technology, Liaoning Normal University, Dalian 116029 (China); Ding, Z. F., E-mail: huowg.wg@tom.com [School of Physics and Optoelectronic Technology, Dalian University of Technology, Dalian 116023 (China)

    2016-08-15

    The overshoot and undershoot of the applied voltage on the electrodes, the discharge current, and radio frequency (RF) power were observed at the initial phase of pulse-modulated (PM) RF atmospheric pressure discharges, but factors influencing the overshoot and undershoot have not been fully elucidated. In this paper, the experimental studies were performed to seek the reasons for the overshoot and undershoot. The experimental results show that the overshoot and undershoot are associated with the pulse frequency, the rise time of pulse signal, and the series capacitor C{sub s} in the inversely L-shaped matching network. In the case of a high RF power discharge, these overshoot and undershoot become serious when shortening the rise time of a pulse signal (5 ns) or operating at a moderate pulse frequency (500 Hz or 1 kHz).

  19. Experimental Study on Indoor Air Cleaning Technique of Nano-Titania Catalysis Under Plasma Discharge

    Gao Deli; Yang Xuechang; Zhou Fei; Wu Yuhuang

    2008-01-01

    In this study, a new technique of air cleaning by plasma combined with catalyst was proposed, which consisted of electrostatic precipitation, volatile organic compounds (VOCs) decomposition and sterilization. A novel indoor air purifier based on this technique was adopted. The experimental results showed that formaldehyde decomposition by the plasma-catalyst hybrid system was more efficient than that by plasma only. Positive discharge was better than negative discharge in formaldehyde removal. Meanwhile, the outlet concentration of ozone byproduct was effectively reduced by the nano-titania catalyst.

  20. Studies on the dilution behaviour of effluent discharged into the CCW channel at KGS

    Sivasubramanian, K.; Srinivasan, S.; Ponraju, D.; Meenakshisundaram, V.; Munusamy, N.

    2003-01-01

    The dilution behaviour of the liquid effluent discharged into condenser cooling water channel of Kaiga Power Plant has been studied using salt addition and dye addition methods. Dilution factors determined experimentally showed that the discharged liquid effluent gets thoroughly mixed with stream of water at the weir and further diluted in the down stream. This paper describes both salt and dye addition methods for determining the dilution factor. The velocity of the stream at various locations were measured and compared with reported values. The selection of representative sampling point for routine analysis of water was identified from this experiment. (author)

  1. Study on law of negative corona discharge in microparticle-air two-phase flow media

    Bo He

    2016-03-01

    Full Text Available To study the basic law of negative corona discharge in solid particle-air two-phase flow, corona discharge experiments in a needle-plate electrode system at different voltage levels and different wind speed were carried out in the wind tunnel. In this paper, the change law of average current and current waveform were analyzed, and the observed phenomena were systematically explained from the perspectives of airflow, particle charging, and particle motion with the help of PIV (particle image velocity measurements and ultraviolet observations.

  2. Pancreatitis - discharge

    Chronic pancreatitis - discharge; Pancreatitis - chronic - discharge; Pancreatic insufficiency - discharge; Acute pancreatitis - discharge ... You were in the hospital because you have pancreatitis. This is a swelling of the pancreas. You ...

  3. Impact of Home Health Care on Health Care Resource Utilization Following Hospital Discharge: A Cohort Study.

    Xiao, Roy; Miller, Jacob A; Zafirau, William J; Gorodeski, Eiran Z; Young, James B

    2018-04-01

    As healthcare costs rise, home health care represents an opportunity to reduce preventable adverse events and costs following hospital discharge. No studies have investigated the utility of home health care within the context of a large and diverse patient population. A retrospective cohort study was conducted between 1/1/2013 and 6/30/2015 at a single tertiary care institution to assess healthcare utilization after discharge with home health care. Control patients discharged with "self-care" were matched by propensity score to home health care patients. The primary outcome was total healthcare costs in the 365-day post-discharge period. Secondary outcomes included follow-up readmission and death. Multivariable linear and Cox proportional hazards regression were used to adjust for covariates. Among 64,541 total patients, 11,266 controls were matched to 6,363 home health care patients across 11 disease-based Institutes. During the 365-day post-discharge period, home health care was associated with a mean unadjusted savings of $15,233 per patient, or $6,433 after adjusting for covariates (p Home health care independently decreased the hazard of follow-up readmission (HR 0.82, p home health care most benefited patients discharged from the Digestive Disease (death HR 0.72, p home health care was associated with significant reduction in healthcare utilization and decreased hazard of readmission and death. These data inform development of value-based care plans. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Studies of transport phenomena in tokamaks with nonstationary intervention into the discharge

    Kalmykov, S.G.

    1993-01-01

    Together with detailed plasma parameter measurements, an experimental basis is provided to deduce radial profiles of local transport coefficients, to obtain their temporal evolution in the transient phase of the discharge. The equations of heat and particle balance were used as proper instrument to perform the coefficients calculation. The majority of the experiments deals with heat transport processes in the electron component of plasma. A problem in getting ohmic heat deposit radial distribution arise with use of the electron population heat balance equation. For its solution, numerical simulation of the plasma column loop voltage based on poloidal magnetic field classical diffusion supposition was used. (L.C.J.A.)

  5. Study of photodissociation parameters of carboxyhemoglobin

    Kuz'min, V V; Salmin, V V; Provorov, A S; Salmina, A B

    2008-01-01

    The general properties of photodissociation of carboxyhemoglobin (HbCO) in buffer solutions of whole human blood are studied by the flash photolysis method on a setup with intersecting beams. It is shown that the efficiency of photoinduced dissociation of the HbCO complex virtually linearly depends on the photolytic irradiation intensity for the average power density not exceeding 45 mW cm -2 . The general dissociation of the HbCO complex in native conditions occurs in a narrower range of values of the saturation degree than in model experiments with the hemoglobin solution. The dependence of the pulse photolysis efficiency of HbCO on the photolytic radiation wavelength in the range from 550 to 585 nm has a broad bell shape. The efficiency maximum corresponds to the electronic Q transition (porphyrin π-π* absorption) in HbCO at a wavelength of 570 nm. No dissociation of the complex was observed under given experimental conditions upon irradiation of solutions by photolytic radiation at wavelengths above 585 nm. (laser applications and other topics in quantum electronics)

  6. Atomization of bismuthane in a dielectric barrier discharge: A mechanistic study

    Kratzer, Jan; Zelina, Ondřej; Svoboda, Milan; Sturgeon, R. E.; Mester, Z.; Dědina, Jiří

    2016-01-01

    Roč. 88, č. 3 (2016), s. 1804-1811 ISSN 0003-2700 R&D Projects: GA ČR GA14-23532S Grant - others:GA AV ČR(CZ) M200311202 Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * hydride generation * mechanistic study Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 6.320, year: 2016

  7. Active prospective surveillance study with post-discharge surveillance of surgical site infections in Cambodia

    José Guerra

    2015-05-01

    Full Text Available Summary: Barriers to the implementation of the Centers for Disease Control and Prevention (CDC guidelines for surgical site infection (SSI surveillance have been described in resource-limited settings. This study aimed to estimate the SSI incidence rate in a Cambodian hospital and to compare different modalities of SSI surveillance. We performed an active prospective study with post-discharge surveillance. During the hospital stay, trained surveyors collected the CDC criteria to identify SSI by direct examination of the surgical site. After discharge, a card was given to each included patient to be presented to all practitioners examining the surgical site. Among 167 patients, direct examination of the surgical site identified a cumulative incidence rate of 14 infections per 100 patients. An independent review of medical charts presented a sensitivity of 16%. The sensitivity of the purulent drainage criterion to detect SSIs was 83%. After hospital discharge, 87% of the patients provided follow-up data, and nine purulent drainages were reported by a practitioner (cumulative incidence rate: 20%. Overall, the incidence rate was dependent on the surveillance modalities. The review of medical charts to identify SSIs during hospitalization was not effective; the use of a follow-up card with phone calls for post-discharge surveillance was effective. Keywords: Surgical wound infection, Cambodia, Infection control, Developing countries, Follow-up studies, Feasibility studies

  8. Atomization of bismuthane in a dielectric barrier discharge: A mechanistic study

    Kratzer, Jan; Zelina, Ondřej; Svoboda, Milan; Sturgeon, R. E.; Mester, Z.; Dědina, Jiří

    2016-01-01

    Roč. 88, č. 3 (2016), s. 1804-1811 ISSN 0003-2700 R&D Projects: GA ČR GA14-23532S Grant - others:GA AV ČR(CZ) M200311202 Institutional support: RVO:68081715 Keywords : dielectric barrier discharge * hydride generation * mechanistic study Subject RIV: CB - Analytical Chemistry , Separation Impact factor: 6.320, year: 2016

  9. Experimental study of hard X-rays emitted from meter-scale positive discharges in air

    P.O. Kochkin (Pavlo); C.V. Nguyen; A. van Deursen (Arie); U. M. Ebert (Ute)

    2012-01-01

    textabstractWe investigate structure and evolution of long positive spark breakdown; and we study at which stage pulses of hard x-rays are emitted. Positive high-voltage pulses of standardized lightning impulse wave form of about 1 MV were applied to about 1 m of ambient air. The discharge evolution

  10. Experimental study on detection of electrostatic discharges generated by polymer granules inside a metal silo

    Choi, Kwangseok; Mogami, Tomofumi; Suzuki, Teruo

    2014-04-01

    To detect electrostatic discharges generated by polymer granules within a metal silo, we developed a novel and simple electrostatic discharge detector that utilizes a photosensor. The novel detector consists of a photosensor module in a metal cylinder, an optical band-pass filter, a quartz glass, a power supply, an amplifier for the photosensor module, and a digital oscilloscope. In this study, we conducted experiments at a real pneumatic powder transport facility that includes a metal silo to evaluate the novel detector using polypropylene granules. To determine the performance of the novel detector, we observed the electrostatic discharge within the metal silo using a conventional image intensifier system. The results obtained from the experiments show that the novel detector worked well in this study. The signals obtained with the novel detector were identical to the electrostatic discharges obtained with the conventional image intensifier system. The greatest advantage of this novel detector is that it is effective even when placed under external lights. In addition, the influence of various optical band-pass filters on the performance of the novel detector was discussed. Our study confirmed that an optical band-pass filter with a center wavelength of λ 330 nm (λ1/2: 315-345 nm) was the best performer among the optical band-pass filters used in this study.

  11. DEM study of granular discharge rate through a vertical pipe with a bend outlet in small absorber sphere system

    Li, Tianjin, E-mail: tjli@tsinghua.edu.cn; Zhang, He; Liu, Malin; Huang, Zhiyong; Bo, Hanliang; Dong, Yujie

    2017-04-01

    Highlights: • The work concerns granular flow in a vertical pipe with a bend. • Discharge rate fluctuation in vertical pipe are mainly from velocity fluctuation. • Steady discharge rate decreases rapidly and saturates with μ{sub s} increasing. • Steady discharge rate W{sub s} still obey the 5/2 power law of pipe internal diameter. • A correlation developed for steady discharge rate for this new geometry. - Abstract: Absorber sphere pneumatic conveying is a special application of pneumatic conveying technique in the pebble bed High Temperature Gas-Cooled Reactor (HTGR or HTR). Granular discharge through a vertical pipe with a bend outlet is one of the control modes to determine solid mass flowrate which is an important parameter for the design of absorber sphere pneumatic conveying. Granular discharge rate through the vertical pipe with a bend outlet in the small absorber sphere system are investigated by discrete element method simulation. The effect of geometry parameters on discharge rate, the discharge rate fluctuation in the vertical pipe, and the effect of friction on steady discharge rate (W{sub s}) are analyzed and discussed. The phenomena of discharge rate fluctuation in the vertical pipe are observed, which are mainly resulted from the evolution of the average downward granular velocity. The steady discharge rate decreases rapidly with sliding friction coefficient increasing from 0.125 to 0.5, and gradually saturates with the friction coefficient further increasing from 0.5 to 1. It is interesting that the linear relation between W{sub s}{sup 2/5} and pipe internal diameter D with zero intercept are found for the vertical pipe discharge with a bend outlet, which is different from the orifice discharge through a hopper or silo with none-zero intercept. A correlation similar to Beverloo’s correlation is developed to predict the steady discharge rate through the vertical pipe with a bend outlet. These results are helpful for the design of sphere

  12. [A study of home care needs of patients at discharge and effects of home care--centered on patients discharged from a rural general hospital].

    Choi, Y S; Kim, D H; Storey, M; Kim, C J; Kang, K S

    1992-01-01

    The study was carried out at W. hospital, an affiliated hospital of Y university, involved a total of 163 patients who were discharged from the hospital between May 1990 and March 1991. Data collection was twice, just prior to discharge and a minimum of three months post discharge. Thirty patients who lived within a hour travel time of the hospital received home care during the three months post discharge. Nursing diagnoses and nursing interventions for these patients were analyzed in this study. The results of the study are summarized as follows: 1. Discharge needs for the subjects of the study were analyzed using Gordon's eleven functional categories and it was found that 48.3% of the total sample had identified nursing needs. Of these, the needs most frequently identified were in the categories of sexuality, 79.3%, health perception, 68.2% self concept, 62.5%, and sleep and rest 62.5%. Looking at the nursing diagnosis that were made for the 30 patients receiving home care, the following diagnoses were the most frequently given; alteration in sexual pattern 79.3%, alterations in health maintenance, 72.6%, alteration in comfort, 68.0%, depression, 64.0%, noncompliance with diet therapy, 63.7%, alteration in self concept, 55.6%, and alteration in sleep pattern, 53%. 2. In looking at the effects of home nursing care as demonstrated by changes in the functional categories over the three month period, it was found that of the 11 functional categories, the need level for health perception, nutrition, activity and self concept decreased slightly over the three month period. On the average sleep patterns improved, but restfulness was slightly less and bowel elimination patterns improved but satisfaction with urinary elimination was slightly less. On the other hand, role enactment, sexuality, stress management and spirituality decreased slightly. The only results that were statistically significant at the 0.05 level were improvement in digestion and decrease in pain. No

  13. The study of multiple PET reconstructed parameter

    Yin, D. Y.; Tian, J.

    2000-01-01

    PET, compared with SPECT, uses some similar techniques in image reconstruction, on the other hand, there are some difference on the techniques. A phantom experiment was conducted and the result was evaluated objectively through quantitative analysis in order to find ideal filter and cutoff frequency (Fc) for clinical application. The PET phantom have 6 solid inserts (cold) in the upper half and 6 hollow ones (hot) in the lower part. The middle insert is 1cm in diameter, the outer five have diameters of 1 to 3cm respectively. The phantom filled with 111 MBq 18 FDG and studied with segmentation acquisition. 25 set of images were reconstructed using HANN, HAMM, PARZEN, BUTTERWORTH, BUTTERWORTH2 filter and 0.1, 0.2, 0.3, 0.4, 0.5 Fe successively.A ROI of 4*4 pixels was drawn over middle 1 cm, outer 1cm, 3 cm cold column area and background area, the ratio between the ROI of cold column and background was calculated to evaluate the image contrast. A ROI of 15*15 pixels was drawn on the background area to get s.d as a judgement of image noise. A profile curve was drawn on the hollow column of middle 1 cm and outer 1 cm and their FWHM were compared with the real diameter to reflect linearity. With the same Fc, the contrast using HANN and HAMM filter was superior to other filter, The effect of the filter on image noise is listed in high to low order as HAMM, HANN, BUTTERWORTH, PARZEN and BUTTERWORTH2. The higher Fc, the higher image noise. The FWHM will increases as the Fc value decreases. With same Fc, the FWHM of different filter from small to big is HAMM, BUTTERWORTH, HANN, PARZEN, BUTTERWORTH2. The outer FWHM is larger than the middle one. For brain image, we suggest HAMM and HANN with Fc 0.3, 0.4 For image demanding lower resolution, we suggest BUTTERWORTH with Fc 0.4, 0.5, 2. For hot image, we can increase Fc to get high resolution. The FWHM value closed to the real value when HANN, HANN with Fc 0.3 and BUTTERWORTH with Fc 0.2. The 5% difference of FWHM between

  14. The Etiology of Vaginal Discharge Syndrome in Zimbabwe Results from the Zimbabwe STI Etiology Study.

    Chirenje, Z Mike; Dhibi, Nicholas; Handsfield, H Hunter; Gonese, Elizabeth; Barr, Beth Tippett; Gwanzura, Lovemore; Latif, Ahmed S; Maseko, Dumisili Venessa; Kularatne, Ranmini S; Tshimanga, Mufuta; Kilmarx, Peter H; Machiha, Anna; Mugurungi, Owen; Rietmeijer, Cornelis A

    2017-11-29

    Symptomatic vaginal discharge is a common gynecological condition managed syndromically in most developing countries. In Zimbabwe, women presenting with symptomatic vaginal discharge are treated with empirical regimens that commonly cover both sexually transmitted infections (STI) and reproductive tract infections, typically including a combination of an intramuscular injection of kanamycin, and oral doxycycline and metronidazole regimens. This study was conducted to determine the current etiology of symptomatic vaginal discharge and assess adequacy of current syndromic management guidelines. We enrolled 200 women with symptomatic vaginal discharge presenting at 6 STI clinics in Zimbabwe. Microscopy was used to detect bacterial vaginosis and yeast infection. Nucleic acid amplifications tests were used to detect Neisseria gonorrhoeae, Chlamydia trachomatis, Trichomonas vaginalis and Mycoplasma genitalium. In addition, serologic testing was performed to detect HIV infection. Of the 200 women, 146 (73%) had an etiology detected, including bacterial vaginosis (24.7%); N. gonorrhoeae (24.0%); yeast infection (20.7%); T. vaginalis (19.0%); C. trachomatis (14.0%) and M. genitalium (7.0%). Among women with STIs (N=90), 62 (68.9%) had a single infection, 18 (20.0%) had a dual infection and 10 (11.1%) had three infections.Of 158 women who consented to HIV testing, 64 (40.5%) were HIV infected.The syndromic management regimen covered 115 (57.5%) of the women in the sample who had gonorrhea, chlamydia, M. genitalium, or bacterial vaginosis, while 85 (42.5%) of women were treated without such diagnosis. Among women presenting with symptomatic vaginal discharge, bacterial vaginosis was the most common etiology and gonorrhea was the most frequently detected STI. The current syndromic management algorithm is suboptimal for coverage of women presenting with symptomatic vaginal discharge; addition of point of care testing could compliment the effectiveness of the syndromic approach.

  15. A study of direct-current surface discharge plasma for a Mach 3 supersonic flow control

    Shin, Jichul

    A direct-current, non-equilibrium surface glow discharge plasma in the presence of a Mach 2.85 flow is studied experimentally for flow control applications. The discharge is generated with pin-like electrodes flush mounted on a ceramic plate with sustaining currents from 25 mA to 300 mA. In the presence of a supersonic flow, two distinct discharge modes - diffuse and constricted - are observed depending on the flow and discharge operating conditions. In cathode upstream location, both diffuse and constricted discharges are observed while in cathode downstream location, the discharge mostly exhibits either constricted mode or bistable mixed mode. The effect of the discharge on the flow ("plasma actuation'') is characterized by the appearance of a weak shock wave in the vicinity of the discharge. The shock is observed at low powers (˜10 W) for the diffuse discharge mode but is absent for the higher power (˜100 W) constricted mode. High speed laser schlieren imaging suggests that the diffuse mode plasma actuation is rapid as it occurs on a time scale that is less than 100 microsec. Rotational (gas) and vibrational temperatures within the discharge are estimated by emission spectral line fits of N 2 and N+2 rovibronic bands near 365-395 nm. The electronic temperatures are estimated by using the Boltzmann plot method for Fe(I) atomic lines. Rotational temperatures are found to be high (˜1500 K) in the absence of a flow but drop sharply (˜500 K) in the presence of a supersonic flow for both the diffuse and constricted discharge modes. The vibrational and electronic temperatures are measured to be about 3000 K and 1.25 eV (14500 K), respectively, and these temperatures are the same with and without flow. The gas (rotational) temperature spatial profiles above the cathode surface are found to be similar for the diffuse and constricted modes indicating that dilatational effects due to gas heating are similar. However, complete absence of flow actuation for the

  16. Heart pacemaker - discharge

    Cardiac pacemaker implantation - discharge; Artificial pacemaker - discharge; Permanent pacemaker - discharge; Internal pacemaker - discharge; Cardiac resynchronization therapy - discharge; CRT - discharge; ...

  17. The prediction of discharge from in-patient psychiatric rehabilitation: a case-control study

    Mountain Debbie A

    2011-09-01

    Full Text Available Abstract Background At any time, about 1% of people with severe and enduring mental illness such as schizophrenia require in-patient psychiatric rehabilitation. In-patient rehabilitation enables individuals with the most challenging difficulties to be discharged to successful and stable community living. However, the length of rehabilitation admission that is required is highly variable and the reasons for this are poorly understood. There are very few case-control studies of predictors of outcome following hospitalisation. None have been carried out for in-patient rehabilitation. We aimed to identify the factors that are associated with achieving discharge from in-patient rehabilitation by carrying out a case-control study. Methods We compared two groups: 34 people who were admitted to the Rehabilitation Service at the Royal Edinburgh Hospital and discharged within a six year study period, and 31 people who were admitted in the same period, but not discharged. We compared the groups on demographic, illness, treatment and risk variables that were present at the point of their admission to rehabilitation. We used independent t tests and Pearson Chi-Square tests to compare the two groups. Results We found that serious self harm and suicide attempts, treatment with high dose antipsychotics, antipsychotic polypharmacy and previous care in forensic psychiatric services were all significantly associated with non-discharge. The non-discharged group were admitted significantly later in the six year study period and had already spent significantly longer in hospital. People who were admitted to rehabilitation within the first ten years of developing psychosis were more likely to have achieved discharge. Conclusions People admitted later in the study period required longer rehabilitation admissions and had higher rates of serious self harm and treatment resistant illness. They were also more likely to have had previous contact with forensic services. This

  18. Desalination Brine Discharge Impacts on Coastal Biology and Water Chemistry - A Case Study from Carlsbad Southern California

    Petersen, K. L.; Heck, N.; Potts, D. C.; Paytan, A.

    2017-12-01

    Fresh water demand is increasing world-wide due to on-going droughts, climate change and increasing human population and associated demand for food and water. Desalination of seawater is a reliable source of potable water; however the effects of byproduct brine discharge from desalination plants on coastal areas have not been thoroughly assessed. Here we report results from in-situmeasurements of the effects of brine discharge on water chemistry and coastal biology from a desalination plant in Carlsbad, Southern California. We compared select parameters in the coastal zone around the discharge site before and after operation began and conducted additional controlled laboratory incubations with key coastal species and brine effluent. Our in-situ data shows differences in salinity and temperature between the discharge area and a control site both before and after the desalination plant started operation. The discharge water is warmer by 3-5 Co than the ambient seawater and a temperature gradient is seen around the discharge channel. This is likely a result of mixing of the desalination brine with power plant cooling water for dilution prior to discharge and the higher temperatures are not directly attributed to the desalination. Our post-discharge results show a decipherable salinity plume at the bottom of the water column ( 6 m depth) reaching up to 600 m offshore from the discharge site. This indicates inefficient mixing of the brine in the coastal discharge zone. No significant differences are found in nutrient levels, organic carbon or chlorophyll a concentrations around the discharge. The benthic biology assemblage post-discharge is significantly different from the pre-discharge organisms' assemblage. However, the role of seasonal changes in temperature may also have impacted the data as the sampling was conducted during different seasons. Controlled incubation experiments of brittle stars (Ophiothrix spiculata) shows no significant difference in growth or

  19. A Study on infrared tracing and monitoring of thermal discharge from the power plants

    Choi, Byung Sun; Hong, Wuk Hee; Kim, Yung Bae; Park, Jang Rae; Choi, Yung An; Park, Yung San [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1996-08-01

    Massive discharge of cooling water from the nuclear power plants as well as many thermal power plants would cause serious environmental problems. Hence, the task of predicting cooling water dispersion areas has enormous importance for better environmental management related with the power plant operation. For the last two decades, extensive field survey and dispersion modeling have been mainly applied to predict thermal discharge dispersion areas. In this study, the method of infrared thermal sensing was tested as a possible means of measuring the affected areas of thermal discharge at the thermal power plant sites. Many IR images obtained by using the terrestrial camera, or by using the airborne scanner, or from the Landsat iv satellite were analyzed from the pc with the IDRISI and resource software and further enhanced with other image analysis technologies. The result of study proved this IR imaging technology to be an potentially cost-effective tool for assessment of water-temperature increase caused by the thermal discharge from the power plants, however, further elaboration of procedure was highly requested. (author). 9 refs., 24 figs.

  20. Epidemiology and clinico-investigative study of organisms causing vaginal discharge

    Venugopal, Swetha; Gopalan, Kannan; Devi, Asha; Kavitha, A.

    2017-01-01

    Background: Abnormal vaginal discharge is a common clinical problem in reproductive age group. It is the second most common problem after abnormal uterine bleeding. It is a neglected health problem, most commonly caused due to vulvovaginal candidiasis, trichomoniasis, and bacterial vaginosis (BV). Objectives: The present study was conducted to determine the prevalence of common organisms causing vaginal discharge and also to know the variety of clinical presentation. Materials and Methods: A cross-sectional descriptive study was conducted in the Skin and STD Outpatient Department of Vinayaka Mission Kirupananda Variyar Medical College Hospital, Salem, who presented with abnormal vaginal discharge between September 2012 and September 2014. A total of 100 women in the reproductive age group who had symptoms of vaginitis were examined. Data were coded and analyzed. Results: Out of the 100 patients examined, 77 (77%) cases were organism positive. Among the positive cases, BV (27%) was the most common microbiological cause of abnormal vaginal discharge, followed by trichomoniasis (25%), vaginal candidiasis (22%), combined infection (Candida and BV) (3%), and nonspecific cases (23%). Conclusion: Out of 100 cases, few cases showed discordance between clinical and laboratory diagnosis. This discordance can be due to pitfalls in identifying the causative agent clinically or obscuring of the findings due to improper treatment received for other ailments. Thus, clinico-investigative correlation is more important than other clinical findings alone. PMID:28442807

  1. A Comparative Study of Distribution System Parameter Estimation Methods

    Sun, Yannan; Williams, Tess L.; Gourisetti, Sri Nikhil Gup

    2016-07-17

    In this paper, we compare two parameter estimation methods for distribution systems: residual sensitivity analysis and state-vector augmentation with a Kalman filter. These two methods were originally proposed for transmission systems, and are still the most commonly used methods for parameter estimation. Distribution systems have much lower measurement redundancy than transmission systems. Therefore, estimating parameters is much more difficult. To increase the robustness of parameter estimation, the two methods are applied with combined measurement snapshots (measurement sets taken at different points in time), so that the redundancy for computing the parameter values is increased. The advantages and disadvantages of both methods are discussed. The results of this paper show that state-vector augmentation is a better approach for parameter estimation in distribution systems. Simulation studies are done on a modified version of IEEE 13-Node Test Feeder with varying levels of measurement noise and non-zero error in the other system model parameters.

  2. Discharge Dialogue

    Horsbøl, Anders

    2012-01-01

    For several years, efforts have been made to strengthen collaboration between health professionals with different specializations and to improve patient transition from hospital to home (care). In the Danish health care system, these efforts have concentrated on cancer and heart diseases, whereas...... coordinator, employed at the hospital, is supposed to anticipate discharge and serve as mediator between the hospital and the municipal home care system. Drawing on methods from discourse and interaction analysis, the paper studies the practice of the discharge coordinator in two encounters between patients...... how the home context provides different resources for identification of patient needs and mutual decision making....

  3. Study of a contracted glow in low-frequency plasma-jet discharges operating with argon

    Minotti, F.; Giuliani, L.; Xaubet, M.; Grondona, D. [Departamento de Física, Facultad de Ciencias Exactas y Naturales, Universidad de Buenos Aires, Buenos Aires, C1428EHA, Buenos Aires, Argentina and Instituto de Física del Plasma (INFIP), Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET), Universidad de Buenos Aires - UBA, C1428EHA, Buenos Aires (Argentina)

    2015-11-15

    In this work, we present an experimental and theoretical study of a low frequency, atmospheric plasma-jet discharge in argon. The discharge has the characteristics of a contracted glow with a current channel of submillimeter diameter and a relatively high voltage cathode layer. In order to interpret the measurements, we consider the separate modeling of each region of the discharge: main channel and cathode layer, which must then be properly matched together. The main current channel was modeled, extending a previous work, as similar to an arc in which joule heating is balanced by lateral heat conduction, without thermal equilibrium between electrons and heavy species. The cathode layer model, on the other hand, includes the emission of secondary electrons by ion impact and by additional mechanisms, of which we considered emission due to collision of atoms excited at metastable levels, and field-enhanced thermionic emission (Schottky effect). The comparison of model and experiment indicates that the discharge can be effectively sustained in its contracted form by the secondary electrons emitted by collision of excited argon atoms, whereas thermionic emission is by far insufficient to provide the necessary electrons.

  4. Microwave discharges in capillary tubes

    Dervisevic, Emil

    1984-01-01

    This research thesis aims at being a contribution to the study of microwave discharge by a surface wave, and more precisely focusses on the discharge in capillary tubes filled with argon. The author first present theoretical models which describe, on the one hand, the propagation of the surface wave along the plasma column, and, on the other hand, longitudinal and radial profiles of the main discharge characteristics. The second part addresses the study of the influence of parameters (gas pressure and tube radius) on discharge operation and characteristics. Laws of similitude as well as empirical relationships between argon I and argon II emission line intensities, electron density, and electric field in the plasma have been established [fr

  5. Experimental study of the polymer powder film thickness uniformity produced by the corona discharge

    Fazlyyyakhmatov, Marsel

    2017-01-01

    The results of an experimental study of the polymer powder film thickness uniformity are presented. Polymer powder films are produced by the electrostatic field of corona discharge. Epoxy and epoxy-polyester powder films with thickness in the range of 30-120 microns are studied. Experimentally confirmed possibility of using these coatings as protective matching layer of piezoceramic transducers at frequencies of 0.5-15 MHz.

  6. Tracer-based quantification of individual frac discharge in single-well multiple-frac backflow: sensitivity study

    Ghergut, Julia; Behrens, Horst; Sauter, Martin

    2014-05-01

    Within the deep-geothermal research project at GroßSchönebeck in the NE German Basin, targeting volcanic rocks (Lower Rotliegend) and siliciclastics (Upper Rotliegend) in the Lower Permian by means of a well doublet with several screening intervals between 3815 and 4247 m b.s.l., several artificial fractures with different geometric and hydraulic characteristics were created at each well, aiming to increase reservoir performance [1], [2]. It could not be told a priori which of the various fracturing treatments was to prove as most promising in terms of future reservoir productivity. At the intended-production well (GS-4), one large-area waterfrac was created in the low-permeability volcanic rocks, and two gel-proppant fractures in selected sandstone layers. Each fracturing treatment was accompanied by the injection of a water-dissolved tracer slug, followed by a defined volume of tracer-free ('chaser') fluid [3]. Each frac received a different species of a sulfonated aromatic acid salt, as a conservative water tracer. During subsequent backflow tests (either gas-based lifting, or production by means of a downhole submersible pump), each frac can contribute a certain (more or less constant) amount to the measured total discharge (also depending on whether and when each frac 'starts' contributing, and which effective aperture and area it actually 'manifests' during the process). Since these individual-frac discharge amounts cannot be measured directly, it was endeavoured to indirectly determine ('resolve') them from tracer signals as detectable in the overall backflow discharge. Therefore, we need to examine how these tracer signals depend on local discharge values and on local hydrogeologic parameters (matrix porosity, permeability distribution; frac transmissivity, thickness, effective area and aperture), and to what extent hydrogeological uncertainty will impede the inversion of local discharge values. To this end, a parameter sensitivity study was conducted on

  7. Pilot scale ion exchange column study for reducing radioactivity discharges to environment

    Kore, S.G.; Yadav, V.K.; Sonar, N.L.; Valsala, T.P.; Narayan, J.; Sharma, S.P.; Chattopadhyay, S.; Dani, U.; Vishwaraj, I.

    2013-01-01

    Low level liquid waste (LLW) is generated during operation of Tarapur Atomic Power Station (TAPS). Chemical co-precipitation is the treatment method used for decontamination of this waste with respect to radionuclide prior to discharge to environment. Further polishing of effluent from the treated LLW was planned using ion exchange column to reduce the discharges to the environment In view of this ion exchange column study was carried out in the laboratory using in-house prepared cobalt ferrocyanide (COFC) based composite resin. Based on the encouraging results obtained in the lab studies, pilot scale study was carried out in the plant. Decontamination factor (DF) of 14-15 was obtained with respect to Cs isotopes and overall DF of 2-5 was obtained with respect to gross beta activity. (author)

  8. A prospective observational study comparing a physiological scoring system with time-based discharge criteria in pediatric ambulatory surgical patients.

    Armstrong, James; Forrest, Helen; Crawford, Mark W

    2015-10-01

    Discharge criteria based on physiological scoring systems can be used in the postanesthesia care unit (PACU) to fast-track patients after ambulatory surgery; however, studies comparing physiological scoring systems with traditional time-based discharge criteria are lacking. The purpose of this study was to compare PACU discharge readiness times using physiological vs time-based discharge criteria in pediatric ambulatory surgical patients. We recorded physiological observations from consecutive American Society of Anesthesiologists physical status I-III patients aged 1-18 yr who were admitted to the PACU after undergoing ambulatory surgery in a tertiary academic pediatric hospital. The physiological score was a combination of the Aldrete and Chung systems. Scores were recorded every 15 min starting upon arrival in the PACU. Patients were considered fit for discharge once they attained a score ≥12 (maximum score, 14), provided no score was zero, with the time to achieve a score ≥12 defining the criteria-based discharge (CBD) time. Patients were discharged from the PACU when both the CBD and the existing time-based discharge (TBD) criteria were met. The CBD and TBD data were compared using Kaplan-Meier and log-rank analysis. Observations from 506 children are presented. Median (interquartile range [IQR]) age was 5.5 [2.8-9.9] yr. Median [IQR] CBD and TBD PACU discharge readiness times were 30 [15-45] min and 60 [45-60] min, respectively. Analysis of Kaplan-Meier curves indicated a significant difference in discharge times using the different criteria (hazard ratio, 5.43; 95% confidence interval, 4.51 to 6.53; P < 0.001). All patients were discharged home without incident. This prospective study suggests that discharge decisions based on physiological criteria have the potential for significantly speeding the transit of children through the PACU, thereby enhancing PACU efficiency and resource utilization.

  9. Thermoluminescence study of the trapped charge at an alumina surface electrode in different dielectric barrier discharge regimes

    Ambrico, P F; Ambrico, M; Dilecce, G; De Benedictis, S [Consiglio Nazionale delle Ricerche, Istituto di Metodologie Inorganiche e dei Plasmi UOS Bari-c/o Dipartimento di Chimica, Universita degli Studi di Bari ' Aldo Moro' , via Orabona, 4, 70126 Bari (Italy); Colaianni, A [Dipartimento di Geologia e Geofisica, Universita degli Studi di Bari ' Aldo Moro' , via Orabona, 4, 70126 Bari (Italy); Schiavulli, L, E-mail: paolofrancesco.ambrico@cnr.i [Dipartimento Interateneo di Fisica, Universita degli Studi di Bari ' Aldo Moro' , via Orabona, 4, 70126 Bari (Italy)

    2010-08-18

    In this study, the charge trapping effect in alumina dielectric surfaces has been deeply investigated by means of a dedicated dielectric barrier discharge apparatus in different discharge regimes and gas mixtures. This work further validates our previous findings in the case of air discharges in a filamentary regime. Long lasting charge trapping has been evidenced by ex situ thermoluminescence characterizations of alumina dielectric barrier plates exposed to a plasma. The density of trapped surface charges was found to be higher in the glow discharge with respect to pseudo-glow and filamentary regimes, and for all regimes the minimum trap activation temperature was 390 K and the trap energy was less than or around 1 eV. This implies that in the case of glow discharges a higher reservoir of electrons is present. Also, the effect was found to persist for several days after running the discharge.

  10. Thermoluminescence study of the trapped charge at an alumina surface electrode in different dielectric barrier discharge regimes

    Ambrico, P F; Ambrico, M; Dilecce, G; De Benedictis, S; Colaianni, A; Schiavulli, L

    2010-01-01

    In this study, the charge trapping effect in alumina dielectric surfaces has been deeply investigated by means of a dedicated dielectric barrier discharge apparatus in different discharge regimes and gas mixtures. This work further validates our previous findings in the case of air discharges in a filamentary regime. Long lasting charge trapping has been evidenced by ex situ thermoluminescence characterizations of alumina dielectric barrier plates exposed to a plasma. The density of trapped surface charges was found to be higher in the glow discharge with respect to pseudo-glow and filamentary regimes, and for all regimes the minimum trap activation temperature was 390 K and the trap energy was less than or around 1 eV. This implies that in the case of glow discharges a higher reservoir of electrons is present. Also, the effect was found to persist for several days after running the discharge.

  11. An experimental study on effect of process parameters in deep ...

    The effects of various deep drawing process parameters were determined by experimental study with the use of Taguchi fractional factorial design and analysis of variance for AA6111 Aluminum alloy. The optimum process parameters were determined based on their influence on the thickness variation at different regions ...

  12. Hairy carbon electrodes studied by cyclic voltammetry and battery discharge testing

    Chung, Deborah D. L.; Shui, Xiaoping; Frysz, Christine A.

    1993-01-01

    Hairy carbon is a new material developed by growing submicron carbon filaments on conventional carbon substrates. Typical substrate materials include carbon black, graphite powder, carbon fibers, and glassy carbon. A catalyst is used to initiate hair growth with carbonaceous gases serving as the carbon source. To study the electrochemical behavior of hairy carbons, cyclic voltammetry (CV) and discharge testing were conducted. In both cases, hairy carbon results surpassed those of the substrate material alone.

  13. Nipple Discharge

    ... any unexpected nipple discharge evaluated by a doctor. Nipple discharge in men under any circumstances could be a problem and needs further evaluation. One or both breasts may produce a nipple discharge, either spontaneously or when you squeeze your ...

  14. Comparative studies of inner and outer divertor discharges and a fueling study in QUEST

    Mitarai, O., E-mail: omitarai@ktmail.tokai-u.jp [Kumamoto Liberal Arts Education Center, Tokai University, 9-1-1 Toroku, Higashi-ku, Kumamoto 862-8652 (Japan); Nakamura, K.; Hasegawa, M.; Onchi, T.; Idei, H.; Fujisawa, A.; Hanada, K.; Zushi, H.; Higashijima, A.; Nakashima, H.; Kawasaki, S. [Research Institute for Applied Mechanics, Kyushu University, 6-1 Kasugakoen, Kasuga 816-8580 Japan (Japan); Matsuoka, K. [National Institute for Fusion Science, 322-6 Oroshi-cho, Toki 509-5292 (Japan); Koike, S.; Takahashi, T. [Division of Electronics and Informatics, Faculty of Science and Technology, Gunma University, 1-5-1 Tenjin-cho, Kiryu, Gunma 376-8515 (Japan); Tsutsui, H. [Research Laboratory for Nuclear Reactors, Tokyo Inst. Tech, 2-12-1 Ookayama, Tokyo 152-8550 (Japan)

    2016-11-01

    Highlights: • Central solenoid has a small flux in QUEST. • Large plasma current is obtained when the position is shifted to the inboard side. • Two types of divertor operation are compared. • Novel merging fueling methods are proposed. • Coaxial helicity injection (CHI) fueling was examined in QUEST divertor configuration. - Abstract: As QUEST has a small central solenoid (CS), a larger Ohmic discharge current has been obtained when the plasma shifts to the inboard side. This tendency restricts a divertor operation to the smaller plasma current regime. As the inner divertor coil has a smaller mutual inductance, it would be expected that its utilization seems to be better for easier plasma current ramp-up for a divertor operation. In this work, we made comparative studies on the plasma current ramp-up for two divertor coils. It is found that while the inner divertor coil with smaller mutual inductance needs a larger coil current, the outer divertor coil with larger mutual inductance needs a smaller coil current for divertor operation. Thus we have found that the plasma current ramp-up characteristics are almost similar for both configurations. We also propose a new fueling method for spherical tokamak (ST) using the coaxial helicity injection (CHI). The main plasma current would be generated at first, and then the CHI plasma current is created between bottom two electrode plates and merged into the main plasma current for fueling.

  15. Long-term study of an estuarine mudflat subjected to petro-chemical discharges

    McLusky, D.A.; Martins, T.

    1998-01-01

    The Kinneil intertidal area, situated in the middle reaches of the Forth estuary, eastern Scotland, has been subject to the effects of industrial discharges, principally from petro-chemical industries (oil refinery and chemical works) since the 1920s. The intertidal fauna has been studied annually since 1976 using consistent methodology. The study continues, now providing over 20 yrs of data. During the study period the discharges from the industrial sources have been reduced substantially through a combination of plant closure and modernization and the installation of effluent treatment works. Furthermore, the River Avon which flows across the area has experienced substantial improvements in water quality, attributed to improvements in waste treatment works at localities upstream from the estuarine site. Overall, however, the clearest trends have been increases in diversity, expressed either as mean number of species per station, or as diversity indices. These increases in diversity are shown to be a clear community response to the improvements made to the petro-chemical wastes discharged to the area. (author)

  16. Study of the cathodic region of a hydrogen luminescent discharge: spectroscopic diagnoses

    Barbeau, Claude

    1991-01-01

    This research thesis addresses the study of the cathodic region of a hydrogen luminescent discharge in direct current, and belongs to the field of studies on plasma-surface interactions, notably in order to understand and optimise electric discharges in H_2CH_4 mixtures used for steel cementation and hard carbon deposition. The author first presents the main characteristics of the abnormal discharge, and details operation conditions as well as the characteristics of the different experimental assemblies. The experimental study of the cathodic region has been mainly performed by high resolution emission spectroscopy, and multi-photon laser spectroscopy (laser-induced fluorescence, optogalvanic effect). In the second part, the author reports an analysis of the Doppler broadening of emission profiles of atomic lines (notably the Balmer series). Experimental results are compared with those of Monte Carlo simulation which addresses mechanisms of creation of excited atoms as well as their energetic distribution. The next parts report the development of methods and techniques for the measurement of the electric field of the cathodic drop and of gas temperature, experimental results and their interpretation [fr

  17. Consumer perspectives of medication-related problems following discharge from hospital in Australia: a quantitative study.

    Eassey, Daniela; Smith, Lorraine; Krass, Ines; McLAchlan, Andrew; Brien, Jo-Anne

    2016-06-01

    The aim of this study was to investigate the consumer's perspectives and experiences regarding medication related problems (MRPs) following discharge from hospital. A cross-sectional study was conducted using an online 80-question survey. Survey participants were recruited through an online market research company. Five hundred and six participants completed the survey. Participants were included if they were aged 50 years or older, taking 5 or more prescription medicines, had been admitted to hospital with a minimum stay of 24 h, admitted to hospital within the last 4 months and discharged from hospital within the last 1 month. The survey comprised questions measuring: health literacy, health status, medication safety (measured by reported MRPs), missed dose(s), role of health professionals, health services and cost, and socio-demographic status. Descriptive and univariate statistics and logistic regression analysis was performed to examine the predictors of experiencing MRPs. Four main risk factors of MRPs emerged as significant: health literacy (P < 0.05), health status (P < 0.05), consumer engagement (P < 0.05) and cost of medicines (P = 0.001). Participants reporting a lack of perceived control over their medicines (OR 6.3; 95% CI: 3.4-11.8) or those who played less of a role in follow-up discussions with their healthcare professionals (OR 7.6; 95% CI: 1.3-45.7) were more likely to experience a self-reported MRP. This study provides insight into consumers' experiences and perceptions of self-reported MRPs following hospital discharge. Results highlight novel findings demonstrating the importance of consumer engagement in developing processes to ensure medication safety on patient discharge. © The Author 2016. Published by Oxford University Press in association with the International Society for Quality in Health Care; all rights reserved.

  18. A novel modelling framework to prioritize estimation of non-point source pollution parameters for quantifying pollutant origin and discharge in urban catchments.

    Fraga, I; Charters, F J; O'Sullivan, A D; Cochrane, T A

    2016-02-01

    Stormwater runoff in urban catchments contains heavy metals (zinc, copper, lead) and suspended solids (TSS) which can substantially degrade urban waterways. To identify these pollutant sources and quantify their loads the MEDUSA (Modelled Estimates of Discharges for Urban Stormwater Assessments) modelling framework was developed. The model quantifies pollutant build-up and wash-off from individual impervious roof, road and car park surfaces for individual rain events, incorporating differences in pollutant dynamics between surface types and rainfall characteristics. This requires delineating all impervious surfaces and their material types, the drainage network, rainfall characteristics and coefficients for the pollutant dynamics equations. An example application of the model to a small urban catchment demonstrates how the model can be used to identify the magnitude of pollutant loads, their spatial origin and the response of the catchment to changes in specific rainfall characteristics. A sensitivity analysis then identifies the key parameters influencing each pollutant load within the stormwater given the catchment characteristics, which allows development of a targeted calibration process that will enhance the certainty of the model outputs, while minimizing the data collection required for effective calibration. A detailed explanation of the modelling framework and pre-calibration sensitivity analysis is presented. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Study of transient phenomena in the Vivitron during an electric discharge

    Roumie, M.

    1994-04-01

    The Vivitron is a new Van der Graaff Tandem type accelerator, which is designed to reach 35 millions volts. The major problem which limits the voltage is the electrical discharge in insulating gas. This discharge leads to a spark short-circuiting two discrete electrodes, or column, and creates a transient developing a high electric field. Damage is observed on the column insulators. The aim of this work is to study the time evolution of the phenomena when the first spark is established. The use of computer simulations, with the PSpice code and physical models based on 'transmission lines' is first justified. Simulations of the real spark by a short-circuit are then carried out, using this model, to explain the progress of transients and to show the voltage modification. Several solutions for this problem are then proposed. (from author) 67 figs., 23 refs

  20. How well do discharge diagnoses identify hospitalised patients with community-acquired infections? - a validation study

    Henriksen, Daniel Pilsgaard; Nielsen, Stig Lønberg; Laursen, Christian Borbjerg

    2014-01-01

    -10 diagnoses was 79.9% (95%CI: 78.1-81.3%), specificity 83.9% (95%CI: 82.6-85.1%), positive likelihood ratio 4.95 (95%CI: 4.58-5.36) and negative likelihood ratio 0.24 (95%CI: 0.22-0.26). The two most common sites of infection, the lower respiratory tract and urinary tract, had positive likelihood......BACKGROUND: Credible measures of disease incidence, trends and mortality can be obtained through surveillance using manual chart review, but this is both time-consuming and expensive. ICD-10 discharge diagnoses are used as surrogate markers of infection, but knowledge on the validity of infections...... in general is sparse. The aim of the study was to determine how well ICD-10 discharge diagnoses identify patients with community-acquired infections in a medical emergency department (ED), overall and related to sites of infection and patient characteristics. METHODS: We manually reviewed 5977 patients...

  1. Modeling study on the effects of pulse rise rate in atmospheric pulsed discharges

    Zhang, Yuan-Tao; Wang, Yan-Hui

    2018-02-01

    In this paper, we present a modeling study on the discharge characteristics driven by short pulsed voltages, focusing on the effects of pulse rise rate based on the fluid description of atmospheric plasmas. The numerical results show that the breakdown voltage of short pulsed discharge is almost linearly dependent on the pulse rise rate, which is also confirmed by the derived equations from the fluid model. In other words, if the pulse rise rate is fixed as a constant, the simulation results clearly suggest that the breakdown voltage is almost unchanged, although the amplitude of pulsed voltage increases significantly. The spatial distribution of the electric field and electron density are given to reveal the underpinning physics. Additionally, the computational data and the analytical expression also indicate that an increased repetition frequency can effectively decrease the breakdown voltage and current density, which is consistent with the experimental observation.

  2. Follow-up services for stroke survivors after hospital discharge--a randomized control study

    Andersen, Hanne Elkjaer; Eriksen, Karen; Brown, Anne

    2002-01-01

    OBJECTIVE: To evaluate whether follow-up services for stroke survivors could improve functional outcome and reduce readmission rate. In this paper results of functional outcome are reported. DESIGN: Randomized controlled trial allocating patients to one of three different types of aftercare: (1......) follow-up home visits by a physician, (2) physiotherapist instruction in the patient's home, or (3) standard aftercare. SUBJECTS: Stroke patients with persisting impairment and disability who, after completing inpatient rehabilitation, were discharged to their homes. OUTCOME MEASURES: Six months after...... discharge, functional outcome was assessed with Functional Quality of Movement, Barthel Index, Frenchay Activity Index and Index of Extended Activites of Daily Living. RESULTS: One-hundred and fifty-five stroke patients were included in the study. Fifty-four received follow-up home visits by a physician, 53...

  3. Development and application of capacitor discharge vaporization technique for fuel aerosol studies

    Kelly, M.J.; Kress, T.S.; Parker, G.W.; Rochelle, J.M.; Fontana, M.H.

    1976-01-01

    Investigations into the behavior of LMFBR fuel as it responds to the levels of energy deposition projected for prompt-critical excursions have been limited because of the difficulty of experimentally achieving the resultant high thermodynamic states in a laboratory. In order to conduct ''source-term'' assessment and fuel aerosol behavioral experiments, the Aerosol Release and Transport program at ORNL has been developing a Capacitor Discharge Vaporization (CDV) technique for using electrical energy, via the discharge from capacitors, to achieve HCDA-like energy state in UO 2 . The paper reports the details of the technique, the developmental test results that have demonstrated feasibility, and a brief description of the proposed experiments that will use the CDV system for safety related studies

  4. A study on the effect of tool electrode thickness on MRR, and TWR in electrical discharge turning process

    Gohil, Vikas; Puri, YM

    2018-04-01

    Turning by electrical discharge machining (EDM) is an emerging area of research. Generally, wire-EDM is used in EDM turning because it is not concerned with electrode tooling cost. In EDM turning wire electrode leaves cusps on the machined surface because of its small diameters and wire breakage which greatly affect the surface finish of the machined part. Moreover, one of the limitations of the process is low machining speed as compared to constituent processes. In this study, conventional EDM was employed for turning purpose in order to generate free-form cylindrical geometries on difficult-to-cut materials. Therefore, a specially designed turning spindle was mounted on a conventional die-sinking EDM machine to rotate the work piece. A conductive preshaped strip of copper as a forming tool is fed (reciprocate) continuously against the rotating work piece; thus, a mirror image of the tool is formed on the circumference of the work piece. In this way, an axisymmetric work piece can be made with small tools. The developed process is termed as the electrical discharge turning (EDT). In the experiments, the effect of machining parameters, such as pulse-on time, peak current, gap voltage and tool thickness on the MRR, and TWR were investigated and practical machining was carried out by turning of SS-304 stainless steel work piece.

  5. Study of excitation energy dependence of nuclear level density parameter

    Mohanto, G.; Nayak, B.K.; Saxena, A.

    2016-01-01

    In the present study, we have populated CN by fusion reaction and excitation energy of the intermediate nuclei is determined after first chance α-emission to investigate excitation energy dependence of the NLD parameter. Evaporated neutron spectra were measured following alpha evaporation for obtaining NLD parameter for the reaction 11 B + 197 Au, populating CN 208 Po. This CN after evaporating an α-particle populates intermediate nucleus 204 Pb. The 204 Pb has magic number of Z=82. Our aim is to study the excitation energy dependence of NLD parameter for closed shell nuclei

  6. Study of dilution of effluent discharged through a sea outfall near Mangalore using radiotracer technique

    Eapen, A.C.; Jain, S.K.

    1987-01-01

    The fate of effluent discharged into water bodies is a matter of concern from the point of view of environmental pollution. Radiotracer techniques have been successfully used to study the change in concentration of effluents while being mixed with large water bodies. The technique used is to add a known concentration of radioactive tracer into the effluent stream and to measure the dilutions at different locations near the effluent discharge point with radiation detectors. M/s Mangalore Chemicals and Fertilizers Ltd (MCF) at Mangalore on the west coast of India disposes off the treated and initially diluted effluent at the rate of about 360 m 3 /h into the sea near by through an outfall extending about 100 meters into the sea. The effluent mainly contains ammonia in the range of 40-50 ppm as the pollutant. It was desired to measure the extent of dilution occurring to the effluent at a few locations of known distances along the sea shore from the discharge point of the effluent. Radiotracers 82 Br as ammonium bromide solution and tritium as tritiated water were employed for the study. The concentration measurement was done at site for 82 Br and by estimation of samples in the laboratory in the case of tritium. Dilution of the order of 1000 was obtained at about 100 meters distance for a continuous injection of about 4 hours. (author). 3 tables, 3 figures

  7. A semi-analytical study of positive corona discharge in wire–plane electrode configuration

    Yanallah, K; Pontiga, F; Chen, J H

    2013-01-01

    Wire-to-plane positive corona discharge in air has been studied using an analytical model of two species (electrons and positive ions). The spatial distributions of electric field and charged species are obtained by integrating Gauss's law and the continuity equations of species along the Laplacian field lines. The experimental values of corona current intensity and applied voltage, together with Warburg's law, have been used to formulate the boundary condition for the electron density on the corona wire. To test the accuracy of the model, the approximate electric field distribution has been compared with the exact numerical solution obtained from a finite element analysis. A parametrical study of wire-to-plane corona discharge has then been undertaken using the approximate semi-analytical solutions. Thus, the spatial distributions of electric field and charged particles have been computed for different values of the gas pressure, wire radius and electrode separation. Also, the two dimensional distribution of ozone density has been obtained using a simplified plasma chemistry model. The approximate semi-analytical solutions can be evaluated in a negligible computational time, yet provide precise estimates of corona discharge variables. (paper)

  8. A semi-analytical study of positive corona discharge in wire-plane electrode configuration

    Yanallah, K.; Pontiga, F.; Chen, J. H.

    2013-08-01

    Wire-to-plane positive corona discharge in air has been studied using an analytical model of two species (electrons and positive ions). The spatial distributions of electric field and charged species are obtained by integrating Gauss's law and the continuity equations of species along the Laplacian field lines. The experimental values of corona current intensity and applied voltage, together with Warburg's law, have been used to formulate the boundary condition for the electron density on the corona wire. To test the accuracy of the model, the approximate electric field distribution has been compared with the exact numerical solution obtained from a finite element analysis. A parametrical study of wire-to-plane corona discharge has then been undertaken using the approximate semi-analytical solutions. Thus, the spatial distributions of electric field and charged particles have been computed for different values of the gas pressure, wire radius and electrode separation. Also, the two dimensional distribution of ozone density has been obtained using a simplified plasma chemistry model. The approximate semi-analytical solutions can be evaluated in a negligible computational time, yet provide precise estimates of corona discharge variables.

  9. Predicting tile drainage discharge

    Iversen, Bo Vangsø; Kjærgaard, Charlotte; Petersen, Rasmus Jes

    used in the analysis. For the dynamic modelling, a simple linear reservoir model was used where different outlets in the model represented tile drain as well as groundwater discharge outputs. This modelling was based on daily measured tile drain discharge values. The statistical predictive model...... was based on a polynomial regression predicting yearly tile drain discharge values using site specific parameters such as soil type, catchment topography, etc. as predictors. Values of calibrated model parameters from the dynamic modelling were compared to the same site specific parameter as used...

  10. Study of plasma discharge evolution and edge turbulence with fast visible imaging in the Aditya tokamak

    Banerjee, Santanu; Manchanda, R.; Chowdhuri, M.B.

    2015-01-01

    Study of discharge evolution through the different phases of a tokamak plasma shot viz., the discharge initiation, current ramp-up, current flat-top and discharge termination, is essential to address many inherent issues of the operation of a Tokamak. Fast visible imaging of the tokamak plasma can provide valuable insight in this regard. Further, edge turbulence is considered to be one of the quintessential areas of tokamak research as the edge plasma is at the immediate vicinity of the plasma core and plays vital role in the core plasma confinement. The edge plasma also bridges the core and the scrape off layer (SOL) of the tokamak and hence has a bearing on the particle and heat flux escaping the plasma column. Two fast visible imaging systems are installed on the Aditya tokamak. One of the system is for imaging the plasma evolution with a wide angle lens covering a major portion of the vacuum vessel. The imaging fiber bundle along with the objective lens is installed inside a radial re-entrant viewport, specially designed for the purpose. Another system is intended for tangential imaging of the plasma column. Formation of the plasma column and its evolution are studied with the fast visible imaging in Aditya. Features of the ECRH and LHCD operations on Aditya will be discussed. 3D filaments can, be seen at the plasma edge all along the discharge and they get amplified in intensity at the plasma termination phase. Statistical analysis of these filaments, which are essentially plasma blobs will be presented. (author)

  11. Using hospital discharge data for determining neonatal morbidity and mortality: a validation study

    Algert Charles S

    2007-11-01

    Full Text Available Abstract Background Despite widespread use of neonatal hospital discharge data, there are few published reports on the accuracy of population health data with neonatal diagnostic or procedure codes. The aim of this study was to assess the accuracy of using routinely collected hospital discharge data in identifying neonatal morbidity during the birth admission compared with data from a statewide audit of selected neonatal intensive care (NICU admissions. Methods Validation study of population-based linked hospital discharge/birth data against neonatal intensive care audit data from New South Wales, Australia for 2,432 babies admitted to NICUs, 1994–1996. Sensitivity, specificity and positive predictive values (PPV with exact binomial confidence intervals were calculated for 12 diagnoses and 6 procedures. Results Sensitivities ranged from 37.0% for drainage of an air leak to 97.7% for very low birthweight, specificities all exceeded 85% and PPVs ranged from 70.9% to 100%. In-hospital mortality, low birthweight (≤1500 g, retinopathy of prematurity, respiratory distress syndrome, meconium aspiration, pneumonia, pulmonary hypertension, selected major anomalies, any mechanical ventilation (including CPAP, major surgery and surgery for patent ductus arteriosus or necrotizing enterocolitis were accurately identified with PPVs over 92%. Transient tachypnea of the newborn and drainage of an air leak had the lowest PPVs, 70.9% and 83.6% respectively. Conclusion Although under-ascertained, routinely collected hospital discharge data had high PPVs for most validated items and would be suitable for risk factor analyses of neonatal morbidity. Procedures tended to be more accurately recorded than diagnoses.

  12. Using hospital discharge data for determining neonatal morbidity and mortality: a validation study

    Ford, Jane B; Roberts, Christine L; Algert, Charles S; Bowen, Jennifer R; Bajuk, Barbara; Henderson-Smart, David J

    2007-01-01

    Background Despite widespread use of neonatal hospital discharge data, there are few published reports on the accuracy of population health data with neonatal diagnostic or procedure codes. The aim of this study was to assess the accuracy of using routinely collected hospital discharge data in identifying neonatal morbidity during the birth admission compared with data from a statewide audit of selected neonatal intensive care (NICU) admissions. Methods Validation study of population-based linked hospital discharge/birth data against neonatal intensive care audit data from New South Wales, Australia for 2,432 babies admitted to NICUs, 1994–1996. Sensitivity, specificity and positive predictive values (PPV) with exact binomial confidence intervals were calculated for 12 diagnoses and 6 procedures. Results Sensitivities ranged from 37.0% for drainage of an air leak to 97.7% for very low birthweight, specificities all exceeded 85% and PPVs ranged from 70.9% to 100%. In-hospital mortality, low birthweight (≤1500 g), retinopathy of prematurity, respiratory distress syndrome, meconium aspiration, pneumonia, pulmonary hypertension, selected major anomalies, any mechanical ventilation (including CPAP), major surgery and surgery for patent ductus arteriosus or necrotizing enterocolitis were accurately identified with PPVs over 92%. Transient tachypnea of the newborn and drainage of an air leak had the lowest PPVs, 70.9% and 83.6% respectively. Conclusion Although under-ascertained, routinely collected hospital discharge data had high PPVs for most validated items and would be suitable for risk factor analyses of neonatal morbidity. Procedures tended to be more accurately recorded than diagnoses. PMID:18021458

  13. Medication details documented on hospital discharge: cross-sectional observational study of factors associated with medication non-reconciliation.

    Grimes, Tamasine C

    2011-03-01

    Movement into or out of hospital is a vulnerable period for medication safety. Reconciling the medication a patient is using before admission with the medication prescribed on discharge, and documenting any changes (medication reconciliation) is recommended to improve safety. The aims of the study were to investigate the factors contributing to medication reconciliation on discharge, and identify the prevalence of non-reconciliation.

  14. Time-resolved study of a pulsed dc discharge using quantum cascade laser absorption spectroscopy : NO and gas temperature kinetics

    Welzel, S.; Gatilova, L.; Röpcke, J.; Rousseau, A.

    2007-01-01

    In a pulsed dc discharge of an Ar–N2 mixture containing 0.91% of NO the kinetics of the destruction of NO has been studied under static and flowing conditions, i.e. in a closed and open discharge tube (p = 266 Pa). For this purpose quantum cascade laser absorption spectroscopy (QCLAS) in the

  15. Infrared gas phase study on plasma-polymer interactions in high-current diffuse dielectric barrier discharge

    Liu, Y.; Welzel, S.; Starostin, S. A.; van de Sanden, M. C. M.; Engeln, R.; de Vries, H. W.

    2017-01-01

    A roll-to-roll high-current diffuse dielectric barrier discharge at atmospheric pressure was operated in air and Ar/N2/O2 gas mixtures. The exhaust gas from the discharge was studied using a high-resolution Fourier-transform infrared spectrometer in the range from 3000 to 750?cm-1 to unravel the

  16. Studies on pulsed optogalvanic effect in Eu/Ne hollow cathode discharge.

    Saini, V K; Kumar, P; Dixit, S K; Nakhe, S V

    2014-07-01

    The optogalvanic (OG) effect has been observed in a Eu/Ne hollow cathode discharge lamp using pulsed laser irradiation. An OG spectrum is recorded in dye laser wavelength region 574–602 nm using a boxcar-averager. In total 41 atomic lines are observed. Of these, 38 lines are assigned to neon transitions. Two lines observed corresponding to wavelengths 576.519 and 601.815 nm are assigned to europium transitions; (4f 7 6s 2 , S 8 7/2 →4f 7 6s6p , zP 6 7/2 ) and (4f 7 6s 2 , S 8 7/2 →4f 7 6s6p , zP 8 9/2 ), respectively, and the remaining line at 582.475 nm could not be assigned. The effect of the discharge current on europium as well as neon OG signals is also studied. At moderate discharge current values, an extra positive peak is observed in neon OG signal for the transition (1s 5 →2p 2 ) at 588.189 nm, which is explained by Penning-ionization process using the quasi-resonant energy transfer interactions between excited neon and europium atoms lying in 2p 2 and D 10 9/2 states, respectively.

  17. Partial discharge measurements on 110kV current transformers. Setting the control value. Case study

    Dan, C.; Morar, R.

    2017-05-01

    The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV CURRENT TRANSFORMERS located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharges. MPD600 consists of one acquisition unit, an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Therefore, measurements, with the ability to be calibrated, do render: - a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 + IEC 61869-5:2011 and IEC 60270: 2000; - the possibility to determine the quantitative limit of PD (a certain control value) to which the equipment can be operated safely and repaired with minimal costs (relative to the high costs implied by eliminating the consequences of a failure) identified empirically (process in which the instrument transformer subjected to the tests was completely destroyed).

  18. Computational study of plasma sustainability in radio frequency micro-discharges

    Zhang, Y.; Jiang, W.; Zhang, Q. Z.; Bogaerts, A.

    2014-01-01

    We apply an implicit particle-in-cell Monte-Carlo (PIC-MC) method to study a radio-frequency argon microdischarge at steady state in the glow discharge limit, in which the microdischarge is sustained by secondary electron emission from the electrodes. The plasma density, electron energy distribution function (EEDF), and electron temperature are calculated in a wide range of operating conditions, including driving voltage, microdischarge gap, and pressure. Also, the effect of gap size scaling (in the range of 50-1000 μm) on the plasma sustaining voltage and peak electron density at atmospheric pressure is examined, which has not been explored before. In our simulations, three different EEDFs, i.e., a so-called three temperature hybrid mode, a two temperature α mode, and a two temperature γ mode distribution, are identified at different gaps and voltages. The maximum sustaining voltage to avoid a transition from the glow mode to an arc is predicted, as well as the minimum sustaining voltage for a steady glow discharge. Our calculations elucidate that secondary electrons play an essential role in sustaining the discharge, and as a result the relationship between breakdown voltage and gap spacing is far away from the Paschen law at atmospheric pressure

  19. Preliminary study on acceptability of scope of thermal discharge mixing zone for nuclear power plant

    Liu Yongye; Yang Yang; Wang Liang; Chen Xiaoqiu; Liu Senlin

    2012-01-01

    Based on the situation that the existing domestic temperature control standards are not performable, the preliminary study on the acceptability of the mixing zone scope of thermal discharge for nuclear power plant was conducted in this paper, taking a coastal power station SNP as a case. The following preliminary conclusions could be drawn from the results of cluster analysis of the SNP site under different results of mathematical modeling and physical model test: 1) The influence intensity of ecological function of the SNP site seawater is small and the scope of thermal discharge mixing zone is acceptable under SNP-1 (Unit 1 and 2) operating condition; 2) the influence intensity of ecological function of the SNP site seawater is small and the scope of thermal discharge mixing zone is acceptable in spring under SNP-1 (Unit 1 and 2) and SNP-2 (Unit 3 and 4) operating condition, while the influence intensity of ecological function of the SNP site seawater is large and the scope of mixing zone is unacceptable in autumn under the same operating condition. (authors)

  20. A paradigm study for assessment of phenylalanine's damage under arc-discharge irradiation

    Ke Zhigang [Laboratory of Ion Beam Bio-engineering, Institute of Plasma Physics of Chinese Academy of Sciences, P.O. Box 1126, Shushanhu Road 350, Hefei 230031 (China); Huang Qing, E-mail: huangq@ipp.ac.c [Laboratory of Ion Beam Bio-engineering, Institute of Plasma Physics of Chinese Academy of Sciences, P.O. Box 1126, Shushanhu Road 350, Hefei 230031 (China); Su Xi; Jiang Jiang; Wang Xiangqin; Yu Zengliang [Laboratory of Ion Beam Bio-engineering, Institute of Plasma Physics of Chinese Academy of Sciences, P.O. Box 1126, Shushanhu Road 350, Hefei 230031 (China)

    2010-05-15

    Energetic ions induce important biological effects and the research into radiolysis of amino acids can help to clarify radiolysis of proteins. For this purpose, arc-discharge induced radiolysis of the benzyl-containing aromatic amino acid phenylalanine in aqueous solution was studied and the damage was assessed quantitatively. The energetic ions were produced by arc-discharge in nitrogen and argon atmosphere. The arc-discharge induced chemical reactions of the biomolecule in aqueous solution were detected and analyzed by means of UV-Vis absorption, fluorescence, Fourier transformation infrared (FTIR) spectroscopy and high performance liquid chromatography (HPLC). Based on the multiple spectroscopic approach, the damage can be evaluated in a more reliable and convenient way. The fluorescence analysis in this case appears to be a more direct indicator for the assessment of damage, where it reveals that the damage increases with the irradiation time exponentially. On the contrary, the 'plateau region' or 'saddle-shape' apparently shown both in our rough absorption analysis and ninhydrin reaction test, similar to the previously reported feature of the dose effect for low-energy-ion induced damage, may be just a consequence with varied reactions and processes involved at different stages. This work thus demonstrated that application of appropriate combination of spectroscopic tools can effectively dissect the diversity of the radiolysis reaction system and assess the biomolecular damage properly.

  1. Numerical simulation of transitions between back discharge regimes

    Jansky, Jaroslav; Lemont, Florent; Bessieres, Delphine; Paillol, Jean

    2014-01-01

    This paper presents numerical simulations of transitions between back discharge regimes. Back discharge refers to any discharge initiated at or near a dielectric layer covering a passive electrode. In this work, a pinhole in a dielectric layer on a plane anode serves as a model for back discharge activity. We have studied transitions between back discharge regimes by varying the surface charge density on the dielectric layer and the electric field in front of the pinhole. From the variation of these two independent parameters, the back discharge regimes have been depicted as a mode diagram inspired by the experimental study of Masuda and Mizuno. The resulting diagram includes the different discharge regimes that are commonly observed in experiments. The propagation of a positive ionizing wave inside the pinhole toward its edge, and the resulting formation of a plasma zone at its exit constitute the onset stage of back discharge. From this stage, the transitions to volume discharge or surface discharge can occur. The volume discharge regime consists of the propagation of a discharge in space toward the cathode which can be superimposed with the propagation of a discharge above the dielectric layer surface. The diagram reveals the conditions for transitions between back discharge regimes. (authors)

  2. Patient outcomes after critical illness: a systematic review of qualitative studies following hospital discharge.

    Hashem, Mohamed D; Nallagangula, Aparna; Nalamalapu, Swaroopa; Nunna, Krishidhar; Nausran, Utkarsh; Robinson, Karen A; Dinglas, Victor D; Needham, Dale M; Eakin, Michelle N

    2016-10-26

    There is growing interest in patient outcomes following critical illness, with an increasing number and different types of studies conducted, and a need for synthesis of existing findings to help inform the field. For this purpose we conducted a systematic review of qualitative studies evaluating patient outcomes after hospital discharge for survivors of critical illness. We searched the PubMed, EMBASE, CINAHL, PsycINFO, and CENTRAL databases from inception to June 2015. Studies were eligible for inclusion if the study population was >50 % adults discharged from the ICU, with qualitative evaluation of patient outcomes. Studies were excluded if they focused on specific ICU patient populations or specialty ICUs. Citations were screened in duplicate, and two reviewers extracted data sequentially for each eligible article. Themes related to patient outcome domains were coded and categorized based on the main domains of the Patient Reported Outcomes Measurement Information System (PROMIS) framework. A total of 2735 citations were screened, and 22 full-text articles were eligible, with year of publication ranging from 1995 to 2015. All of the qualitative themes were extracted from eligible studies and then categorized using PROMIS descriptors: satisfaction with life (16 studies), including positive outlook, acceptance, gratitude, independence, boredom, loneliness, and wishing they had not lived; mental health (15 articles), including symptoms of post-traumatic stress disorder, anxiety, depression, and irritability/anger; physical health (14 articles), including mobility, activities of daily living, fatigue, appetite, sensory changes, muscle weakness, and sleep disturbances; social health (seven articles), including changes in friends/family relationships; and ability to participate in social roles and activities (six articles), including hobbies and disability. ICU survivors may experience positive emotions and life satisfaction; however, a wide range of mental

  3. Astrophysical parameters of ten poorly studied open star clusters

    Tadross, Ashraf Latif; El-Bendary, Reda; Osman, Anas; Ismail, Nader; Bakry, Abdel Aziz

    2012-01-01

    We present the fundamental parameters of ten open star clusters, nominated from Kronberger et al. who presented some newly discovered stellar groups on the basis of the Two Micron All Sky Survey photometry and Digitized Sky Survey visual images. Star counts and photometric parameters (radius, membership, distance, color excess, age, luminosity function, mass function, total mass, and dynamical relaxation time) have been determined for these ten clusters for the first time. In order to calibrate our procedures, the main parameters (distance, age, and color excess) have been re-estimated for another five clusters, which are also studied by Kronberger et al. (research papers)

  4. Dialysis Modality and Readmission Following Hospital Discharge: A Population-Based Cohort Study.

    Perl, Jeffrey; McArthur, Eric; Bell, Chaim; Garg, Amit X; Bargman, Joanne M; Chan, Christopher T; Harel, Shai; Li, Lihua; Jain, Arsh K; Nash, Danielle M; Harel, Ziv

    2017-07-01

    Readmissions following hospital discharge among maintenance dialysis patients are common, potentially modifiable, and costly. Compared with patients receiving in-center hemodialysis (HD), patients receiving peritoneal dialysis (PD) have fewer routine dialysis clinic encounters and as a result may be more susceptible to a hospital readmission following discharge. Population-based retrospective-cohort observational study. Patients treated with maintenance dialysis who were discharged following an acute-care hospitalization during January 1, 2003, to December 31, 2013, across 164 acute-care hospitals in Ontario, Canada. For those with multiple hospitalizations, we randomly selected a single hospitalization as the index hospitalization. Dialysis modality PD or in-center HD. Propensity scores were used to match each patient on PD therapy to 2 patients on in-center HD therapy to ensure that baseline indicators of health were similar between the 2 groups. All-cause 30-day readmission following the index hospital discharge. 28,026 dialysis patients were included in the study. 4,013 PD patients were matched to 8,026 in-center HD patients. Among the matched cohort, 30-day readmission rates were 7.1 (95% CI, 6.6-7.6) per 1,000 person-days for patients on PD therapy and 6.0 (95% CI, 5.7-6.3) per 1,000 person-days for patients on in-center HD therapy. The risk for a 30-day readmission among patients on PD therapy was higher compared with those on in-center HD therapy (adjusted HR, 1.19; 95% CI, 1.08-1.31). The primary results were consistent across several key prespecified subgroups. Lack of information for the frequency of nephrology physician encounters following discharge from the hospital in both the PD and in-center HD cohorts. Limited validation of International Classification of Diseases, Tenth Revision codes. The risk for 30-day readmission is higher for patients on home-based PD compared to in-center HD therapy. Interventions to improve transitions in care between the

  5. Delivery parameters, neonatal parameters and incidence of urinary incontinence six months postpartum: a cohort study.

    Wesnes, Stian Langeland; Hannestad, Yngvild; Rortveit, Guri

    2017-10-01

    Contradictory results have been reported regarding most delivery parameters as risk factors for urinary incontinence. We investigated the association between the incidence of urinary incontinence six months postpartum and single obstetric risk factors as well as combinations of risk factors. This study was based on the Norwegian Mother and Child Cohort Study, conducted by the Norwegian Institute of Public Health during 1998-2008. This substudy was based on 7561 primiparous women who were continent before and during pregnancy. Data were obtained from questionnaires answered at weeks 15 and 30 of pregnancy and six months postpartum. Data were linked to the Medical Birth Registry of Norway. Single and combined delivery- and neonatal parameters were analyzed by logistic regression analyses. Birthweight was associated with significantly higher risk of urinary incontinence six months postpartum [3541-4180 g: odds ratio (OR) 1.4, 95% confidence interval (CI) 1.2-1.6; >4180 g: OR 1.6, 95% CI 1.2-2.0]. Fetal presentation, obstetric anal sphincter injuries, episiotomy and epidural analgesia were not significantly associated with increased risk of urinary incontinence. The following combinations of risk factors among women delivering by spontaneous vaginal delivery increased the risk of urinary incontinence six months postpartum; birthweight ≥3540 g and ≥36 cm head circumference; birthweight ≥3540 g and forceps, birthweight ≥3540 g and episiotomy; and ≥36 cm head circumference and episiotomy. Some combinations of delivery parameters and neonatal parameters seem to act together and may increase the risk of incidence of urinary incontinence six months postpartum in a synergetic way. © 2017 Nordic Federation of Societies of Obstetrics and Gynecology.

  6. Glow discharge in singlet oxygen

    Vagin, N.P.; Ionin, A.A.; Klimachev, Yu.M.; Sinitsyn, D.V.; Yuryshev, N.N.; Kochetov, I.V.; Napartovich, A.P.

    2003-01-01

    Currently, there is no experimental data on the plasma balance in gas mixtures with a high content of singlet delta oxygen O 2 ( 1 Δ g ). These data can be obtained by studying the parameters of an electric discharge in singlet oxygen produced by a chemical generator. The O 2 ( 1 Δ g ) molecules significantly change the kinetics of electrons and negative ions in plasma. Hence, the discharge conditions at low and high O 2 ( 1 Δ g ) concentrations are very different. Here, the parameters of the positive column of a glow discharge in a gas flow from a chemical singlet-oxygen generator are studied. It is experimentally shown that, at an O 2 ( 1 Δ g ) concentration of 50% and at pressures of 1.5 and 2 torr, the electric field required to sustain the discharge is considerably lower than in the case when all of the oxygen molecules are in the ground state. A theoretical model of the glow discharge is proposed whose predictions are in good agreement with the experimental data

  7. Spillover effects in epidemiology: parameters, study designs and methodological considerations

    Benjamin-Chung, Jade; Arnold, Benjamin F; Berger, David; Luby, Stephen P; Miguel, Edward; Colford Jr, John M; Hubbard, Alan E

    2018-01-01

    Abstract Many public health interventions provide benefits that extend beyond their direct recipients and impact people in close physical or social proximity who did not directly receive the intervention themselves. A classic example of this phenomenon is the herd protection provided by many vaccines. If these ‘spillover effects’ (i.e. ‘herd effects’) are present in the same direction as the effects on the intended recipients, studies that only estimate direct effects on recipients will likely underestimate the full public health benefits of the intervention. Causal inference assumptions for spillover parameters have been articulated in the vaccine literature, but many studies measuring spillovers of other types of public health interventions have not drawn upon that literature. In conjunction with a systematic review we conducted of spillovers of public health interventions delivered in low- and middle-income countries, we classified the most widely used spillover parameters reported in the empirical literature into a standard notation. General classes of spillover parameters include: cluster-level spillovers; spillovers conditional on treatment or outcome density, distance or the number of treated social network links; and vaccine efficacy parameters related to spillovers. We draw on high quality empirical examples to illustrate each of these parameters. We describe study designs to estimate spillovers and assumptions required to make causal inferences about spillovers. We aim to advance and encourage methods for spillover estimation and reporting by standardizing spillover parameter nomenclature and articulating the causal inference assumptions required to estimate spillovers. PMID:29106568

  8. Contribution to the thermal study of a dielectric barrier discharge reactor

    Dubus, Nicolas

    2009-01-01

    This thesis aims to study the thermal behaviour of a laboratory Dielectric Barrier Discharge (DBD) reactor. An experimental study was first realized to measure temperatures at different points of the reactor by using optic fibers. These measurements were performed in transient and steady states. To examine the influence of heat losses, not insulated and insulated reactors were considered. The influence of the nature and the form of the applied voltage was else considered. Experiments were conducted with a sinusoidal voltage and a pulsed power supply. (author) [fr

  9. Improved communication in post-ICU care by improving writing of ICU discharge letters: a longitudinal before-after study.

    Medlock, Stephanie; Eslami, Saeid; Askari, Marjan; van Lieshout, Erik Jan; Dongelmans, Dave A; Abu-Hanna, Ameen

    2011-11-01

    The discharge letter is the primary means of communication at patient discharge, yet discharge letters are often not completed on time. A multifaceted intervention was performed to improve communication in patient hand-off from the intensive care unit (ICU) to the wards by improving the timeliness of discharge letters. A management directive was operationalised by a working group of ICU staff in a longitudinal before-after study. The intervention consisted of (a) changing policy to require a letter for use as a transfer note at the time of ICU discharge, (b) changing the assignment of responsibility to an automatic process, (c) leveraging positive peer pressure by making the list of patients in need of letters visible to colleagues and (d) provision of decision support, through automatic copying of important content from the patient record to the letter and email reminders if letters were not written on time. Statistical process control charts were used to monitor the longitudinal effect of the intervention. The intervention resulted in a 77.9% absolute improvement in the proportion of patients with a complete transfer note at the time of discharge, and an 85.2% absolute improvement in the number of discharge letters written. Statistical process control shows that the effect was sustained over time. A multifaceted intervention can be highly effective for improving discharge communication from the ICU.

  10. Nanosecond Pulsed Discharge in Water without Bubbles: A Fundamental Study of Initiation, Propagation and Plasma Characteristics

    Seepersad, Yohan

    The state of plasma is widely known as a gas-phase phenomenon, but plasma in liquids have also received significant attention over the last century. Generating plasma in liquids however is theoretically challenging, and this problem is often overcome via liquid-gas phase transition preceding the actual plasma formation. In this sense, plasma forms in gas bubbles in the liquid. Recent work at the Drexel Plasma Institute has shown that nanosecond pulsed electric fields can initiate plasma in liquids without any initial cavitation phase, at voltages below theoretical direct-ionization thresholds. This unique regime is poorly understood and does not fit into any current descriptive mechanisms. As with all new phenomena, a complete fundamental description is paramount to understanding its usefulness to practical applications. The primary goals of this research were to qualitatively and quantitatively understand the phenomenon of nanosecond pulsed discharge in liquids as a means to characterizing properties that may open up niche application possibilities. Analysis of the plasma was based on experimental results from non-invasive, sub-nanosecond time-resolved optical diagnostics, including direct imaging, transmission imaging (Schlieren and shadow), and optical emission spectroscopy. The physical characteristics of the plasma were studied as a function of variations in the electric field amplitude and polarity, liquid permittivity, and pulse duration. It was found that the plasma size and emission intensity was dependent on the permittivity of the liquid, as well as the voltage polarity, and the structure and dynamics were explained by a 'cold-lightning' mechanism. The under-breakdown dynamics at the liquid-electrode interface were investigated by transmission imaging to provide evidence for a novel mechanism for initiation based on the electrostriction. This mechanism was proposed by collaborators on the project and developed alongside the experimental work in this

  11. Reactor parameters for European economic, safety and environmental studies

    Hancox, R.; Cooke, P.I.H.; Spears, W.R.

    1990-01-01

    Parameter sets for five 1200 MW e tokamak reactors were developed for the European Study Group on the Environmental, Safety-related and Economic Potential of Fusion Power, showing today's perception of the range of reactors likely to be available as a result of the Commission's fusion programme. On the basis of the cost of generating electricity, relative to a fission reactor, a reference set was chosen and endorsed by the Group for further studies including that on the environmental impact of fusion power. Key physics and technology parameters for the reference reactor are compared with values used in the ITER design, and with those from American studies. (author)

  12. [Study on Hexagonal Super-Lattice Pattern with Light Spot and Dim Spot in Dielectric Barrier Discharge by Optical Emission Spectra].

    Liu, Ying; Dong, Li-fang; Niu, Xue-jiao; Zhang, Chao

    2016-02-01

    The hexagonal super-lattice pattern composed of the light spot and the dim spot is firstly observed and investigated in the discharge of gas mixture of air and argon by using the dielectric barrier discharge device with double water electrodes. It is found that the dim spot is located at the center of its surrounding three light spots by observing the discharge image. Obviously, the brightness of the light spot and the dim spot are different, which indicates that the plasma states of the light spot and the dim spot may be different. The optical emission spectrum method is used to further study the several plasma parameters of the light spot and the dim spot in different argon content. The emission spectra of the N₂ second positive band (C³IIu --> B³IIg) are measured, from which the molecule vibration temperatures of the light spot and the dim spot are calculated. Based on the relative intensity ratio of the line at 391.4 nm and the N₂ line at 394.1 nm, the average electron energies of the light spot and the dim spot are investigated. The broadening of spectral line 696.57 nm (2P₂-1S₅) is used to study the electron densities of the light spot and the dim spot. The experiment shows that the molecule vibration temperature, average electron energy and the electron density of the dim spot are higher than those of the light spot in the same argon content. The molecule vibration temperature and electron density of the light spot and dim spot increase with the argon content increasing from 70% to 95%, while average electron energies of the light spot and dim spot decrease gradually. The short-exposure image recorded by a high speed video camera shows that the dim spot results from the surface discharges (SDs). The surface discharge induced by the volume discharge (VD) has the decisive effect on the formation of the dim spot. The experiment above plays an important role in studying the formation mechanism of the hexagonal super-lattice pattern with light spot and

  13. Study on the Energetic Parameters in a Photothermic Sensor with ...

    Study on the Energetic Parameters in a Photothermic Sensor with Black Polymeric Film. ... The evolution of incidental solar illumination on the horizontal plan of sensor and the temperature distribution are studied. Results showed that the ... Keywords: film, solar energy, greenhouse effect, design, radiation, illumination.

  14. Study of 99mTc in the discharge of public hospitals in Granada

    Pinero Garcia, F.; Krawczyk, E.; Ferro Garcia, M. A.

    2011-01-01

    The main objective is to determine the activity levels of 99m Tc in the discharge of two public hospitals in Granada, Nuclear Medicine Service at the point of controlling them. The reasons for this study are due to higher doses may be administered until 10 to 20 mCi, to produce images with better definition due to the relative safety of this radionuclide. Which will be reflected later in the highest values ??of activity found for this isotope of technetium in these effluents.

  15. Study of the three-step photoionization of uranium using a hollow cathode discharge tube

    Hu, Q.; Yin, L.; Zhang, Y.; Jin, C.; Cui, J.; Su, H.; Lin, F.

    1986-01-01

    The hollow cathode discharge (HCD) tube as a spectral light source has been developed. Because any element including refractory metals can be atomized by the cathode sputtering effect in HCD, a simple and reliable atomic vapor source produced by HCD has been widely used in laser spectroscopy. To the authors' knowledge, there is no previous work on the photoionization processes of metal atoms using an HCD tube. Here the authors report their study of the resonant three-step ionization of U in a homemade HCD tube

  16. Studies of the disruption prevention by ECRH at plasma current rise stage in limiter discharges

    Alikaev, V.V.; Borshegovskij, A.A.; Chistyakov, V.V.

    1999-01-01

    Studies of disruption prevention by means of ECRH in T-10 at the plasma current rise phase in limiter discharges with circular plasma cross-section were performed. Reliable disruption prevention by ECRH at HF power (P HF ) min level equal to 20% of ohmic heating power P OH was demonstrated. m/n=2/1 mode MHD-activity developed before disruption (with characteristic time ∼120 ms) can be considered as disruption precursor and can be used in a feedback system. (author)

  17. Study of thermal and hydraulic phenomena going along with the discharge of hot waters from a power generation plant

    Syrmalenios, Panayotis

    1973-01-01

    This short research thesis aims at taking stock of problems raised by the discharge of high temperature water from a power plant into rivers, lakes and seas from a thermal and hydraulic point of view. The author proposes an overview of ecological, legal, and recirculation problems. He describes the various phenomena going along these discharges at the vicinity of the discharge and far from it. He also proposes an overview of methods used to study these thermal and hydraulic effects: 'in-situ' studies, experimental methods, theoretical methods. Appendices address floating jets and layered flows [fr

  18. A numerical study of non-linear crack tip parameters

    F.V. Antunes

    2015-07-01

    Full Text Available Crack closure concept has been widely used to explain different issues of fatigue crack propagation. However, different authors have questioned the relevance of crack closure and have proposed alternative concepts. The main objective here is to check the effectiveness of crack closure concept by linking the contact of crack flanks with non-linear crack tip parameters. Accordingly, 3D-FE numerical models with and without contact were developed for a wide range of loading scenarios and the crack tip parameters usually linked to fatigue crack growth, namely range of cyclic plastic strain, crack tip opening displacement, size of reversed plastic zone and total plastic dissipation per cycle, were investigated. It was demonstrated that: i LEFM concepts are applicable to the problem under study; ii the crack closure phenomenon has a great influence on crack tip parameters decreasing their values; iii the Keff concept is able to explain the variations of crack tip parameters produced by the contact of crack flanks; iv the analysis of remote compliance is the best numerical parameter to quantify the crack opening level; v without contact there is no effect of stress ratio on crack tip parameters. Therefore it is proved that the crack closure concept is valid.

  19. Handgrip strength predicts functional decline at discharge in hospitalized male elderly: a hospital cohort study.

    Carmen García-Peña

    Full Text Available Functional decline after hospitalization is a common adverse outcome in elderly. An easy to use, reproducible and accurate tool to identify those at risk would aid focusing interventions in those at higher risk. Handgrip strength has been shown to predict adverse outcomes in other settings. The aim of this study was to determine if handgrip strength measured upon admission to an acute care facility would predict functional decline (either incident or worsening of preexisting at discharge among older Mexican, stratified by gender. In addition, cutoff points as a function of specificity would be determined. A cohort study was conducted in two hospitals in Mexico City. The primary endpoint was functional decline on discharge, defined as a 30-point reduction in the Barthel Index score from that of the baseline score. Handgrip strength along with other variables was measured at initial assessment, including: instrumental activities of daily living, cognition, depressive symptoms, delirium, hospitalization length and quality of life. All analyses were stratified by gender. Logistic regression to test independent association between handgrip strength and functional decline was performed, along with estimation of handgrip strength test values (specificity, sensitivity, area under the curve, etc.. A total of 223 patients admitted to an acute care facility between 2007 and 2009 were recruited. A total of 55 patients (24.7% had functional decline, 23.46% in male and 25.6% in women. Multivariate analysis showed that only males with low handgrip strength had an increased risk of functional decline at discharge (OR 0.88, 95% CI 0.79-0.98, p = 0.01, with a specificity of 91.3% and a cutoff point of 20.65 kg for handgrip strength. Females had not a significant association between handgrip strength and functional decline. Measurement of handgrip strength on admission to acute care facilities may identify male elderly patients at risk of having functional decline

  20. Handgrip Strength Predicts Functional Decline at Discharge in Hospitalized Male Elderly: A Hospital Cohort Study

    García-Peña, Carmen; García-Fabela, Luis C.; Gutiérrez-Robledo, Luis M.; García-González, Jose J.; Arango-Lopera, Victoria E.; Pérez-Zepeda, Mario U.

    2013-01-01

    Functional decline after hospitalization is a common adverse outcome in elderly. An easy to use, reproducible and accurate tool to identify those at risk would aid focusing interventions in those at higher risk. Handgrip strength has been shown to predict adverse outcomes in other settings. The aim of this study was to determine if handgrip strength measured upon admission to an acute care facility would predict functional decline (either incident or worsening of preexisting) at discharge among older Mexican, stratified by gender. In addition, cutoff points as a function of specificity would be determined. A cohort study was conducted in two hospitals in Mexico City. The primary endpoint was functional decline on discharge, defined as a 30-point reduction in the Barthel Index score from that of the baseline score. Handgrip strength along with other variables was measured at initial assessment, including: instrumental activities of daily living, cognition, depressive symptoms, delirium, hospitalization length and quality of life. All analyses were stratified by gender. Logistic regression to test independent association between handgrip strength and functional decline was performed, along with estimation of handgrip strength test values (specificity, sensitivity, area under the curve, etc.). A total of 223 patients admitted to an acute care facility between 2007 and 2009 were recruited. A total of 55 patients (24.7%) had functional decline, 23.46% in male and 25.6% in women. Multivariate analysis showed that only males with low handgrip strength had an increased risk of functional decline at discharge (OR 0.88, 95% CI 0.79–0.98, p = 0.01), with a specificity of 91.3% and a cutoff point of 20.65 kg for handgrip strength. Females had not a significant association between handgrip strength and functional decline. Measurement of handgrip strength on admission to acute care facilities may identify male elderly patients at risk of having functional decline, and

  1. PRELIMINARY STUDY OF HEMATOLOGICAL PARAMETERS IN HERZEGOVINIAN DONKEY

    Dunja Rukavina

    2016-02-01

    Full Text Available Herzegovinian donkey is a very important animal resource of Bosnia and Herzegovina. There have been no works attempted at determining the normal values of hematological parameters of Herzegovinian donkey. For this reason, the objective of the present study was to investigate some hematological parameters in Herzegovinian donkey. The research was performed on 30 apparently healthy donkeys (18 female and 12 male of ages from 1 to 20 years. Blood samples (3 ml were obtained by jugular vein puncture (vena jugularis externa in vacuum tubes with EDTA. The mean value of hematocrit was 29.19 %, hemoglobin concentration 10.6 g/dl, mean corpuscular hemoglobin concentration 36.33 g/dl, white blood cells 9.33 x109/L, granulocytes (109/L 5.45 x109/L, granulocytes (% 59.47%, lymphocyte/monocyte (109/L 3.89 x109/L, lymphocyte/monocyte (% 40.53% and platelet cells 148.97 x109/L. Parameters were determined using an automated analyzer IDEXX QBC VET AutoRead. Data were analyzed by SPSS V 15. All hematological parameters (except platelet cells were consistent with the recommended reference ranges for donkeys, and the values found in literature so far. Platelet cells values were much lower than in the literature for the other donkey breeds and the recommended reference ranges for donkeys. The slight differences found between our results and those reported in the previous works confirm the need for further studies to investigate the reference values of hematological parameters of Herzegovinian donkey. This work is a contribution to the study of hematological parameters of Herzegovinian donkey, and we expect these data to be applied to the further studies.

  2. Experimental study of ultra-low q discharges in the linear Extrap L1 device

    Brunsell, P.; Karlsson, Per.

    1991-01-01

    Linear pinch discharges with combined octupole and longitudinal magnetic fields are experimentally studied in the Extrap L1 device. Plasma currents are around I p =10 kA, plasma temperautres are up to T e =50 eV and plasma densities are of the order of n=5x10 21 m -3 . The plasma equilibria are in the ultra-low q (ULQ) regime corresponding to operation with plasma currents in excess of the Kruskal-Shafranov stability limit (q less than 1). The plasma current exhibits the typical time behaviour seen in toroidal ULQ experiments; the unstable setting up phase and the step-wise decay with current levels corresponding to q-values in windows between rational values. Longitudinal plasma current generated by radial plasma diffusion is seen, with amplitudes up to 30% of the externally driven current during the initial phase of the discharge. The effect of the octupole magnetic field on the ULQ confinement is investigated. The plasma temperature increases by more than a factor of two, for the optimum octupole rod current (I v =I p ), compared to the case without octupole field. A plasma current limitation for stable operation corresponding to q bigger than 1/2 is observed, excepts for low axial magnetic field strength. In the low axial field regime, the octupole field alone provides sufficient stabilization for operation with q less than 1/2. Plasma density and temperature both increase linearly with applied axial magnetic field. The density shows a strong, approximately exponential, dependence on discharge voltage. (au)

  3. Radon as a natural geochemical tracer for study of groundwater discharge into lakes

    Schmidt, Axel

    2008-01-01

    In the presented work the suitability of the naturally occurring radioactive noble gas isotope radon-222 for qualitative and quantitative description of groundwater discharge into lakes was studied. Basis of these investigations was the development of two innovative techniques for the on-site determination of radon in water. In the ex-situ radon measurement procedure, water from the source concerned is taken up in an exchange cell used for this purpose. Inside this cell, the radon dissolved in water is transferred via diffusion into a closed counter-flow of air and subsequently detected by a radon-in-air monitor. Where the in-situ radon determination is concerned, a module composed of a semipermeable membrane is introduced into a water column. Subsequently, the radon dissolved in the water body diffuses through the membrane into the corresponding air flow, by means of which it is transferred into a radon-in-air monitor and is detected. Combination of the developed mobile radon extraction techniques with a suitable and portable radon monitor allow the detection of radon-222 with sufficient accuracy (smaller 20 %) in groundwater as well as in surface waters, i.e., within a broad range of concentrations. Radon-222 was subsequently used to characterize groundwater discharge into a meromictic and a dimictic lake, i.e. two types of lake basically distinct from each other with respect to their water circulation properties were investigated. The use of the noble gas isotope radon-222 as a geochemical tracer makes the application of on-site detection techniques possible and that this in turn permits a rapid, reliable, and cost-effective assessment of groundwater discharge rates into lake water bodies

  4. Radon as a natural geochemical tracer for study of groundwater discharge into lakes

    Schmidt, Axel

    2008-06-27

    In the presented work the suitability of the naturally occurring radioactive noble gas isotope radon-222 for qualitative and quantitative description of groundwater discharge into lakes was studied. Basis of these investigations was the development of two innovative techniques for the on-site determination of radon in water. In the ex-situ radon measurement procedure, water from the source concerned is taken up in an exchange cell used for this purpose. Inside this cell, the radon dissolved in water is transferred via diffusion into a closed counter-flow of air and subsequently detected by a radon-in-air monitor. Where the in-situ radon determination is concerned, a module composed of a semipermeable membrane is introduced into a water column. Subsequently, the radon dissolved in the water body diffuses through the membrane into the corresponding air flow, by means of which it is transferred into a radon-in-air monitor and is detected. Combination of the developed mobile radon extraction techniques with a suitable and portable radon monitor allow the detection of radon-222 with sufficient accuracy (smaller 20 %) in groundwater as well as in surface waters, i.e., within a broad range of concentrations. Radon-222 was subsequently used to characterize groundwater discharge into a meromictic and a dimictic lake, i.e. two types of lake basically distinct from each other with respect to their water circulation properties were investigated. The use of the noble gas isotope radon-222 as a geochemical tracer makes the application of on-site detection techniques possible and that this in turn permits a rapid, reliable, and cost-effective assessment of groundwater discharge rates into lake water bodies.

  5. Study of the Dissociative Processes in O_2 Discharges. Development of an Atomic Oxygen Beam Source

    Pagnon, Daniel

    1992-01-01

    The first part of this work is devoted to the study of dissociative processes in an oxygen glow discharge at low pressure (0,1-5 Torr, 1-80 mA). The kinetics of oxygen atoms has been determined supported by the measurements of atomic concentrations by VUV absorption spectroscopy and actinometry. The reaction coefficients for dissociative excitation and direct excitation of oxygen atoms have been calculated using the cross sections of the literature and a previously calculated EEDF. It has been demonstrated that dissociative excitation is negligible in respect with direct excitation for dissociation rates smaller than 2,5 %. An upper limit of 20 % for dissociative rates is observed. This limit has been explained by the increase of the atomic recombination at the discharge wall with increasing wall temperature. Using all these results, we have designed and optimized a source of oxygen atoms which has then been adapted on a MBE device. The spatial distribution of the atomic density has been measured in molecular jet by laser induced fluorescence (LIF) and Resonant Multi-Photon Ionization (RMPI). A stimulated emission has been evidenced and the coefficient for this process evaluated. A model for the effusion of atoms has been developed from which the flow of atoms on the sample can be predicted. This source has already been used in industrial MBE devices for in-situ oxidation of copper films, superconductors, and substrates for VLSI high speed applications. The methodology of this work and the diagnostics developed can be applied to other kinds of discharges, of other molecular gases, to design sources of atoms for the treatment of large area samples. (author) [fr

  6. Theoretical and experimental studies of the magnetic fields of Rotamak discharge

    Kirolous, H.

    1986-12-01

    In part I of this thesis, the self-generated bi-directional toroidal magnetic field structure which has been observed to exist in previous rotamak discharges is theoretically investigated. A possible explanation for the existence of this self-generated field, which relies on the presence of screening currents in the plasma, is advanced. Experimental studies of the magnetic field structure of a rotamak plasma configuration generated and sustained in a metal discharge vessel by means of a rotating magnetic field are described in part II. The rotating magnetic field was produced by feeding radio frequency (r.f.) currents, dephased by 90 degrees, through two orthogonal coils which were located inside the metal chamber. High power amplifiers were used to supply the r.f. current pulses. The efficiency of the r.f. power transfer to the plasma was maximized by using impedance matching networks. The effect on the rotating magnetic field of eddy currents induced in the conducting vessel has been theoretically and experimentally investigated. Extensive magnetic field measurements have been undertaken on one particular rotamak discharge. Measurements of the penetration of the rotating magnetic field into the plasma were made at various axial positions. The steady magnetic field structure was measured at a matrix of 2640 points and a two dimensional least square polynomial fitting algorithm was used to smooth the measured data. This fitting procedure enabled reliable plots of the poloidal flux and current density contours to be constructed. An attempt has been made to apply MHD equilibrium theory to the observed plasma/field configuration. 23 refs., 99 figs., ills

  7. Numerical studies of independent control of electron density and gas temperature via nonlinear coupling in dual-frequency atmospheric pressure dielectric barrier discharge plasmas

    Zhang, Z. L.; Nie, Q. Y.; Wang, Z. B.; Gao, X. T.; Kong, F. R.; Sun, Y. F.; Jiang, B. H.

    2016-01-01

    Dielectric barrier discharges (DBDs) provide a promising technology of generating non-equilibrium cold plasmas in atmospheric pressure gases. For both application-focused and fundamental studies, it is important to explore the strategy and the mechanism for enabling effective independent tuning of key plasma parameters in a DBD system. In this paper, we report numerical studies of effects of dual-frequency excitation on atmospheric DBDs, and modulation as well as separate tuning mechanism, with emphasis on dual-frequency coupling to the key plasma parameters and discharge evolution. With an appropriately applied low frequency to the original high frequency, the numerical calculation demonstrates that a strong nonlinear coupling between two frequencies governs the process of ionization and energy deposition into plasma, and thus raises the electron density significantly (e.g., three times in this case) in comparisons with a single frequency driven DBD system. Nevertheless, the gas temperature, which is mainly determined by the high frequency discharge, barely changes. This method then enables a possible approach of controlling both averaged electron density and gas temperature independently.

  8. Shoulder replacement - discharge

    Total shoulder arthroplasty - discharge; Endoprosthetic shoulder replacement - discharge; Partial shoulder replacement - discharge; Partial shoulder arthroplasty - discharge; Replacement - shoulder - discharge; Arthroplasty - shoulder - discharge

  9. Computational Study of the Hydrodynamic Behavior during Air Discharge through a Sparger Submerged in the Condensation Pool

    Ahn, Hyung-Joon; Bang, Young-Seok; Kim, In-Goo; Kim, Hho-Jung; Lee, Byeong-Eun; Kwon, Soon-Bum

    2002-01-01

    The In-containment Refueling Water Storage Tank (IRWST) has the function of heat sink when steam is released from the pressurizer. The hydrodynamic behaviors occurring at the sparger are very complex because of the wide variety of operating conditions and the complex geometry. Hydrodynamic behavior when air is discharged through a sparger in a condensation pool is investigated using CFD techniques in the present study. The effect of pressure acting on the sparger header during both water and air discharge through the sparger is studied. In addition, pressure oscillation occurring during air discharge through the sparger is studied for a better understanding of mechanisms of air discharge and a better design of the IRWST, including sparger. (authors)

  10. A Study of Electromagnetic Radiation of Corona Discharge Near 500-Kv Electric Installations

    Korzhov, A. V.; Okrainskaya, I. S.; Sidorov, A. I.; Kufel'd, V. D.

    2004-01-01

    Data on the spectral composition and intensity of electromagnetic radiation of corona discharge are obtained in an experimental study performed on the outdoor switchgear of the Shagol 500-kV substation of the Chelyabinsk Enterprise of Trunk Transmission Grids and under a 500-kV Shagol - Kozyrevo overhead transmission line. The electromagnetic environment on the territory of the 500-kV outdoor switchgear is shown to be determined by narrow-band radiations (harmonics of the frequency of electric supply) and wide-band radiations due to corona discharges of high-voltage sources. This means that the personnel experience the action of a commercial-frequency electric field and electromagnetic radiation of a quite wide range, which is not allowed for by the existing guidelines. It is recommended to continue the study in cooperation with medical institutions in order to create guidelines that would allow for the joint action of commercial-frequency electric field and electromagnetic radiation and for the voltage in the line, the current load, the meteorological situation, and other factors

  11. [Study on plasma temperature of a large area surface discharge by optical emission spectrum].

    Dong, Li-Fang; Tong, Guo-Liang; Zhang, Yu; Zhou, Bin

    2014-04-01

    A large area surface discharge was realized in air/argon gas mixture by designing a discharge device with water electrodes. By using optical emission spectrum, the variations of the molecular vibrational temperature, the mean energy of electron, and the electronic excitation temperature as a function of the gas pressure were studied. The nitrogen molecular vibrational temperature was calculated according to the emission line of the second positive band system of the nitrogen molecule (C3 pi(u) --> B 3 pi(g)). The electronic excitation temperature was obtained by using the intensity ratio of Ar I 763.51 nm (2P(6) --> 1S(5)) to Ar I 772.42 nm (2P(2) --> 1S(3)). The changes in the mean energy of electron were studied by the relative intensity ratio of the nitrogen molecular ion 391.4 nm to nitrogen 337.1 nm. It was found that the intensity of emission spectral line increases with the increase in the gas pressure, meanwhile, the outline and the ratios of different spectral lines intensity also change. The molecular vibrational temperature, the mean energy of electron, and the electronic excitation temperature decrease as the gas pressure increases from 0.75 x 10(5) Pa to 1 x 10(5) Pa.

  12. A comparative study on the activity of TiO2 in pulsed plasma under different discharge conditions

    Lijuan, DUAN; Nan, JIANG; Na, LU; Kefeng, SHANG; Jie, LI; Yan, WU

    2018-05-01

    In the present study, a combination of pulsed discharge plasma and TiO2 (plasma/TiO2) has been developed in order to study the activity of TiO2 by varying the discharge conditions of pulsed voltage, discharge mode, air flow rate and solution conductivity. Phenol was used as the chemical probe to characterize the activity of TiO2 in a pulsed discharge system. The experimental results showed that the phenol removal efficiency could be improved by about 10% by increasing the applied voltage. The phenol removal efficiency for three discharge modes in the plasma-discharge-alone system was found to be highest in the spark mode, followed by the spark–streamer mode and finally the streamer mode. In the plasma/TiO2 system, the highest catalytic effect of TiO2 was observed in the spark–streamer discharge mode, which may be attributed to the favorable chemical and physical effects from the spark–streamer discharge mode, such as ultraviolet light, O3, H2O2, pyrolysis, shockwaves and high-energy electrons. Meanwhile, the optimal flow rate and conductivity were 0.05 m3 l‑1 and 10 μS cm‑1, respectively. The main phenolic intermediates were hydroquinone, catechol, and p-benzoquinone during the discharge treatment process. A different phenol degradation pathway was observed in the plasma/TiO2 system as compared to plasma alone. Analysis of the reaction intermediates demonstrated that p-benzoquinone reduction was selectively catalyzed on the TiO2 surface. The effective decomposition of phenol constant (D e) increased from 74.11% to 79.16% when TiO2 was added, indicating that higher phenol mineralization was achieved in the plasma/TiO2 system.

  13. The normative study of acoustic parameters in normal Egyptian ...

    Yehia A. Abo-Ras

    2013-03-21

    Mar 21, 2013 ... all children were subjected to computerized acoustic analysis using Multidimensional voice program ... cal quality is important for social relations to happen effectively. ... lish comparative parameters with the normal values of the acoustic ... from lower age ranges in the normative studies since the child's.

  14. Developing the Parameters of Scholarship in Postgraduate Coursework Studies

    McLay, Allan F.

    2013-01-01

    Scholarship parameters, in relation to postgraduate coursework studies, are developed against the expectations of the Boyer classifications of scholarship (Boyer, 1990) with particular emphasis on the role of minor thesis development. An example is presented in which postgraduate coursework students are required to undertake a three semester minor…

  15. Parameters of importance to determine in geoscientific site studies

    Andersson, Johan; Almen, K.E.; Ericsson, L.O.; Karlsson, Fred; Stroem, A.; Fredriksson, Anders; Stanfors, R.

    1996-12-01

    This report identifies and describes parameters, that may be determined in a site characterization study, for performing functional and safety analyses of a deep rock repository for radioactive wastes. The report discusses data needs for rock engineering and for description of other environmental aspects. It is intended that the report be used as a basis for formulating the criteria of acceptance in evaluating a candidate site. The report describes how different parameters influence the safety function, and how they are evaluated in practice. The logical order of performing measurements, due to the need of in-data and influence on other measurements is also discussed. 65 refs

  16. Control of dangerous substances in discharges and microbiological abatement: European framework and a case study of an ozone disinfection system.

    Ostoich, M; Serena, F; Falletti, L; Fantoni, A

    2013-01-01

    Directive 2000/60/EC requires the achievement of a 'good chemical status' for surface water within pre-established dates. Disinfection is needed to achieve compulsory final microbial limit values (in Italy for wastewater discharges the parameter Escherichia coli - EC - is imposed by law with a maximum limit value of 5,000 cfu/100 mL). Liquid waste and disinfection by-products must be considered when designing appropriate monitoring of dangerous substances; the specific classes of substances must be investigated according to the typology of received wastewaters and liquid wastes (where applicable) and specific analytical techniques, with Limit of Detection (LOD) lower than the limit values, must be applied; the difficulties faced by national and regional environmental control Agencies is that these techniques have to be applied during ordinary activity and not only for research purposes. The study aims to present the control of dangerous substances, as a screening view, in wastewater treatment plant (WWTP) discharges in the province of Venice (Northern Italy) for the period 2007-2010 based on available data from institutional controls. In addition, the wastewater disinfection process with ozone applied to a medium size WWTP (45,000 Population Equivalents) is presented as a case study, with a view to assessing the microbiological abatement efficacy and the presence of dangerous substances. Discharge quality of the WWTPs in the province of Venice presented mean values that were higher than the LOD, but only for certain metals. For the Paese plant, zinc and chloroform were the only micro-pollutants detected with a higher level than the LOD. From microbiological data in the period 2006-2011 the disinfection abatement efficiency for Paese was, in most cases above 99% for EC, faecal coliform (FC), faecal streptococci (FS) while efficiency was slightly lower for total coliform (TC); however, the proposed criterion aimed at respecting 99.99% abatement was not completely

  17. A Numerical Study of the Sour Gas Reforming in a Dielectric Barrier Discharge Reactor

    Sajedeh Shahsavari

    2016-10-01

    Full Text Available In this paper, using a one-dimensional simulation model, the reforming process of sour gas, i.e. CH4, CO2, and H2S, to the various charged particles and syngas in a dielectric barrier discharge (DBD reactor is studied. An electric field is applied across the reactor radius, and thus a non-thermal plasma discharge is formed within the reactor. Based on the space-time coupled finite element method, the governing equations are solved, and the temporal and spatial profiles of different formed charged species from sour gas inside the plasma reactor are verified. It is observed that the electric field increases radially towards the cathode electrode. Moreover, the electron density growth rate at the radial positions closer to the cathode surface is smaller than the one in the anode electrode region. Furthermore, as time progresses, the positive ions density near the anode electrode is higher. In addition, the produced syngas density is mainly concentrated in the proximity of anode dielectric electrode.

  18. Studies of improved electron confinement in low density L-mode National Spherical Torus Experiment discharges

    Stutman, D.; Finkenthal, M.; Tritz, K.; Redi, M. H.; Kaye, S. M.; Bell, M. G.; Bell, R. E.; LeBlanc, B. P.; Hill, K. W.; Medley, S. S.; Menard, J. E.; Rewoldt, G.; Wang, W. X.; Synakowski, E. J.; Levinton, F.; Kubota, S.; Bourdelle, C.; Dorland, W.; The NSTX Team

    2006-01-01

    Electron transport is rapid in most National Spherical Torus Experiment, M. Ono et al., Nucl. Fusion 40, 557 (2000) beam heated plasmas. A regime of improved electron confinement is nevertheless observed in low density L-mode (''low-confinement'') discharges heated by early beam injection. Experiments were performed in this regime to study the role of the current profile on thermal transport. Variations in the magnetic shear profile were produced by changing the current ramp rate and onset of neutral beam heating. An increased electron temperature gradient and local minimum in the electron thermal diffusivity were observed at early times in plasmas with the fastest current ramp and earliest beam injection. In addition, an increased ion temperature gradient associated with a region of reduced ion transport is observed at slightly larger radii. Ultrasoft x-ray measurements of double-tearing magnetohydrodynamic activity, together with current diffusion calculations, point to the existence of negative magnetic shear in the core of these plasmas. Discharges with slower current ramp and delayed beam onset, which are estimated to have more monotonic q-profiles, do not exhibit regions of reduced transport. The results are discussed in the light of the initial linear microstability assessment of these plasmas, which suggests that the growth rate of all instabilities, including microtearing modes, can be reduced by negative or low magnetic shear in the temperature gradient region. Several puzzles arising from the present experiments are also highlighted

  19. Comparative study of energy-efficiency and conservation systems for ceramic metal-halide discharge lamps

    Hermoso Orzáez, Manuel Jesús; Andrés Díaz, José Ramón de

    2013-01-01

    Interest in energy savings in urban lighting is gaining traction and has become a priority for municipal administrations. LED (light-emitting diode) technology appears to be the clear future lighting choice. However, this technology is still rapidly developing and has not been sufficiently tested. As an intermediate step, alternative proposals for energy-saving equipment for traditional discharge lamps are desirable so that the current technologies can coexist with the new LED counterparts for the short and medium term. This article provides a comparative study between two efficiency and energy-saving systems for discharge lamps with metal-halide and ceramic technologies, i.e., a lighting flow dimmer-stabilizer and a double-level electronic ballast. - Highlights: ► It has been demonstrated the possibility of regulating ceramic metal-halide lamps with lighting flow dimmer-stabilizer. ► Electronic ballasts can save approximately double quantity of energy than lighting flow dimmer-stabilizers. ► The use of lighting flow dimmer-stabilizer is more profitable than electronic ballasts due to costs and reliability

  20. Hospital discharge bags and breastfeeding at 6 months: data from the infant feeding practices study II.

    Sadacharan, Radha; Grossman, Xena; Matlak, Stephanie; Merewood, Anne

    2014-02-01

    Distribution of industry-sponsored formula sample packs to new mothers undermines breastfeeding. Using data from the Infant Feeding Practices Study II (IFPS II), we aimed to determine whether receipt of 4 different types of bags was associated with exclusive breastfeeding during the first 6 months of life. We extracted data from IFPS II questionnaires. Type of discharge bag received was categorized as "formula bag," "coupon bag," "breastfeeding supplies bag," or "no bag". We examined exclusive breastfeeding status at 10 weeks (post hoc) and at 6 months using univariate descriptive analyses and multivariate logistic regression models, controlling for sociodemographic and attitudinal variables. Overall, 1868 (81.4%) of women received formula bags, 96 (4.2%) received coupon bags, 46 (2.0%) received breastfeeding supplies bags, and 284 (12.4%) received no bag. By 10 weeks, recipients of breastfeeding supplies bags or no bag were significantly more likely to be exclusively breastfeeding than formula bag recipients. In the adjusted model, compared to formula bag/coupon bag recipients, recipients of breastfeeding supplies bag/no bag were significantly more likely to breastfeed exclusively for 6 months (odds ratio = 1.58; 95% confidence interval, 1.06-2.36). The vast majority of new mothers received formula sample packs at discharge, and this was associated with reduced exclusive breastfeeding at 10 weeks and 6 months. Bags containing breastfeeding supplies or no bag at all were positively associated with exclusive breastfeeding at 10 weeks and 6 months.

  1. Synthesis of electric discharge alloyed nickel–tungsten coating on tool steel and its tribological studies

    Arun, Ilangovan; Duraiselvam, Muthukannan; Senthilkumar, V.; Narayanasamy, R.; Anandakrishnan, V.

    2014-01-01

    Highlights: • Electrical discharge alloying/coating made on AISI D2 tool steel. • The hardness of EDA layer is three to four time higher than the base material. • The dry sliding wear tests performed on EDA layer at different temperatures. • The alloyed layer acts as a self-lubricant at higher temperature. - Abstract: The present study examines the method of depositing nickel and tungsten on die steel surface by means of dispersing these elements in dielectric fluid in an electrical discharge alloying (EDA) process. The modified surface was mechanically and metallurgically characterized using Scanning Electron Microscopy (SEM), Energy-Dispersive X-ray spectroscopy (EDX), microhardness tester and Pin-on-disc tribometer. The phase transformations that occurred during EDA process were evaluated by XRD. The deposition of Ni and W on die steel surfaces yielded minimal cracks with excellent metallurgical bonding. Higher hardness (∼1059 HV 0.3 ) with little brittleness resulted in superior wear resistance properties, a property which was retained even at elevated temperature

  2. Studies on gas breakdown in pulsed radio frequency atmospheric pressure glow discharges

    Huo, W. G.; Jian, S. J.; Yao, J.; Ding, Z. F.

    2014-01-01

    In pulsed RF atmospheric pressure glow discharges, the gas breakdown judged by the rapid drop in the amplitude of the pulsed RF voltage is no longer universally true. The steep increment of the plasma-absorbed RF power is proposed to determine the gas breakdown. The averaged plasma-absorbed RF power over a pulse period is used to evaluate effects of the preceding pulsed RF discharge on the breakdown voltage of the following one, finding that the breakdown voltage decreases with the increment in the averaged plasma-absorbed RF power under constant pulse duty ratio. Effects of the pulse off-time on the breakdown voltage and the breakdown delay time are also studied. The obtained dependence of the breakdown voltage on the pulse off-time is indicative of the transitional plasma diffusion processes in the afterglow. The breakdown voltage varies rapidly as the plasma diffuses fast in the region of moderate pulse off-time. The contribution of nitrogen atom recombination at the alumina surface is demonstrated in the prolonged memory effect on the breakdown delay time vs. the pulse off-time and experimentally validated by introducing a trace amount of nitrogen into argon at short and long pulse off-times

  3. Operational river discharge forecasting in poorly gauged basins: the Kavango River basin case study

    Bauer-Gottwein, Peter; Jensen, Iris Hedegaard; Guzinski, R.

    2015-01-01

    in Africa. We present an operational probabilistic forecasting approach which uses public-domain climate forcing data and a hydrologic-hydrodynamic model which is entirely based on open-source software. Data assimilation techniques are used to inform the forecasts with the latest available observations......Operational probabilistic forecasts of river discharge are essential for effective water resources management. Many studies have addressed this topic using different approaches ranging from purely statistical black-box approaches to physically based and distributed modeling schemes employing data...... assimilation techniques. However, few studies have attempted to develop operational probabilistic forecasting approaches for large and poorly gauged river basins. The objective of this study is to develop open-source software tools to support hydrologic forecasting and integrated water resources management...

  4. Monte Carlo parameter studies and uncertainty analyses with MCNP5

    Brown, F. B.; Sweezy, J. E.; Hayes, R.

    2004-01-01

    A software tool called mcnp p study has been developed to automate the setup, execution, and collection of results from a series of MCNP5 Monte Carlo calculations. This tool provides a convenient means of performing parameter studies, total uncertainty analyses, parallel job execution on clusters, stochastic geometry modeling, and other types of calculations where a series of MCNP5 jobs must be performed with varying problem input specifications. (authors)

  5. Study of pipe-whip parameters in pipelines

    Guerreiro, J.N.C.; Loula, A.F.D.; Galeao, A.C.N.R.

    1980-01-01

    The problem of the high energy pipe-whip, assuming an elastic-plastic behavior for the tube material and taking in account the internal pressure, is studied. The constraints are simulated as bilinear springs and viscous dampers. A general research, based on the finite element method was developed to analyse the phenomenon. The influence of the following parameters: gap, damping coefficient, stiffness, constraints positioning and internal pressure of the tube is studied. (Author) [pt

  6. [Experimental study of the effects of impulse-electric discharge on chemotaxis and cytoadhesion of urinary infection pathogens].

    Kuderinov, S K; Azizov, I S; Turgunov, E M; Shambilova, N A

    2006-01-01

    The aim of the experimental study was to evaluate effects of impulse-electric discharge in liquid on chemotaxis and cytoadhesion of urinary infection pathogens. Chemotaxis was determined in respect to the lung, liver, spleen, kidney, ureter, urinary bladder, urethra of white mice by S. Likholetov's modified method. Cytoadhesion was assessed by V. Brilis. The experiments show that the impulse-electric discharge holds promise for urological practice.

  7. FTIR study of decomposition of carbon dioxide in dc corona discharges

    Horvath, G; Skalny, J D; Mason, N J

    2008-01-01

    The decomposition rate of carbon dioxide and the generation of ozone and carbon monoxide in coaxial corona discharges fed by pure CO 2 has been investigated in a dc corona discharge operated in both positive and negative polarities using FTIR spectroscopy. The degree of CO 2 decomposition is found to be dependent on the voltage, U, with a maximum CO 2 decomposition of nearly 10% found in a negative corona discharge for U = 7.5 kV. In all cases the amount of CO 2 decomposition was lower in positive polarity discharges than in negative polarity discharges operated under same conditions. CO and ozone were found to be the main products observed in the discharges.

  8. FTIR study of decomposition of carbon dioxide in dc corona discharges

    Horvath, G; Skalny, J D [Department of Experimental Physics, Comenius University, Mlynska dolina F-2, 842 48, Bratislava (Slovakia); Mason, N J [Open University, Department of Physics and Astronomy, Walton Hall, Milton Keynes MK7 6AA (United Kingdom)

    2008-11-21

    The decomposition rate of carbon dioxide and the generation of ozone and carbon monoxide in coaxial corona discharges fed by pure CO{sub 2} has been investigated in a dc corona discharge operated in both positive and negative polarities using FTIR spectroscopy. The degree of CO{sub 2} decomposition is found to be dependent on the voltage, U, with a maximum CO{sub 2} decomposition of nearly 10% found in a negative corona discharge for U = 7.5 kV. In all cases the amount of CO{sub 2} decomposition was lower in positive polarity discharges than in negative polarity discharges operated under same conditions. CO and ozone were found to be the main products observed in the discharges.

  9. Study on residual discharge time of lead-acid battery based on fitting method

    Liu, Bing; Yu, Wangwang; Jin, Yueqiang; Wang, Shuying

    2017-05-01

    This paper use the method of fitting to discuss the data of C problem of mathematical modeling in 2016, the residual discharge time model of lead-acid battery with 20A,30A,…,100A constant current discharge is obtained, and the discharge time model of discharge under arbitrary constant current is presented. The mean relative error of the model is calculated to be about 3%, which shows that the model has high accuracy. This model can provide a basis for optimizing the adaptation of power system to the electrical motor vehicle.

  10. Preliminary Studies on Aerodynamic Control with Direct Current Discharge at Hypersonic Speed

    Watanabe, Yasumasa; Takama, Yoshiki; Imamura, Osamu; Watanuki, Tadaharu; Suzuki, Kojiro

    A new idea of an aerodynamic control device for hypersonic vehicles using plasma discharges is presented. The effect of DC plasma discharge on a hypersonic flow is examined with both experiments and CFD analyses. It is revealed that the surface pressure upstream of plasma area significantly increases, which would be preferable in realizing a new aerodynamic control devices. Such pressure rise is also observed in the result of analyses of the Navier-Stokes equations with energy addition that simulates the Joule heating of a plasma discharge. It is revealed that the pressure rise due to the existence of the plasma discharge can be qualitatively explained as an effect of Joule heating.

  11. Study on Self-discharge Behavior of Lithium-Sulfur Batteries

    Knap, Vaclav; Stroe, Daniel Loan; Swierczynski, Maciej Jozef

    2015-01-01

    Lithium-Sulfur (Li-S) batteries are a promising energy storage technology, which draws interest due to their high theoretical limits in terms of specific capacity, specific energy and energy density. However as a drawback, they suffer from a high self-discharge rate, which is mainly caused...... by ongoing polysulfide shuttle. In this paper, the self-discharge behavior of Li-S batteries is experimentally investigated, considering various conditions as depth-of-discharge, temperature and idling time. The self-discharge rate under different conditions is identified and quantified. Moreover...

  12. Experimental study and DEM simulation of granular flow through a new sphere discharge valve

    Zhang He; Li Tianjin; Huang Zhiyong; Gao Zhi; Qi Weiwei; Bo Hanliang

    2015-01-01

    Experiments and DEM simulation have been conducted to investigate the granular flow through a new type of sphere discharge valve. The new sphere discharge valve was based on the principle of angle of repose. The glass sphere was used in the granular discharge experiments. Experimental results showed that the relation between the averaging sphere discharge mass flow rate and the stroke of the sphere discharge valve were consisted of three zones, i.e. the idle stroke zone, linearly zone and orifice restriction zone. The Beverloo's law was suitable for the granular flow through multi-orifices in the orifice restriction zone. The variation of averaging sphere discharge mass flow rate with the stroke of the sphere discharge valve was described by Beverloo's law with the modification based on the stroke of the sphere discharge valve. DEM simulation results showed that the drained angle of repose during granular flow in the sphere storage vessel remained 23 degrees with different stroke of the sphere discharge valve. (authors)

  13. Study of Ag and Au Nanoparticles Synthesized by Arc Discharge in Deionized Water

    Der-Chi Tien

    2010-01-01

    Full Text Available The paper presents a study of Ag and Au nanofluids synthesized by the arc discharge method (ADM in deionized water. The metallic Ag nanoparticle (Ag0 and ionic Ag (Ag+ have played an important role in the battle against germs which are becoming more drug-resistant every year. Our study indicates that Ag nanoparticle suspension (SNPS fabricated by using ADM without added surfactants exclusively contains the metallic Ag nanoparticle and ionic Ag. Besides that, the ADM in deionized water has also been employed for the fabrication process of Au nanoparticles. The experimental results indicate that the prepared Ag nanoparticles can react with the dissolved H2CO3 in deionized water, leading to the formation of Ag2CO3. Significantly different to Ag, the prepared Au nanoparticles with their surfaces bonded by oxygen are suspended in deionized water by the formation of hydrogen bonded with the neighboring water molecules.

  14. In-situ marine monitoring and environmental management of SWRO concentrate discharge: A case study of the KAUST SWRO plant

    Van Der Merwe, Riaan

    2014-06-01

    Concentrate (when discharged to the ocean) may have chronic/acute impacts on marine ecosystems, particularly in the mixing zone around outfalls. The environmental impact of the desalination plant discharges is very site- and volumetric specific, and depends to a great extent on the salinity tolerance of the specific marine microbial communities as well as higher order organisms inhabiting the water column in and around this extreme discharge environment. Scientific studies that aim to grant insight into possible impacts of concentrate discharge are very important, in order to understand how this may affect different marine species when exposed to elevated salinity levels or residual chemicals from the treatment process in the discharge site. The objective of this PhD research was to investigate the potential environmental effects of the concentrate discharge in the near-field area around the submerged discharge of the King Abdullah University of Science and Technology (KAUST) seawater reverse osmosis (SWRO) plant by a combination of biological and hydrological studies. Possible changes in microbial abundance were assessed by using flow cytometric (FCM) analysis on a single-cell level in 107 samples, taken from the discharge area, the feed-water intake area and two control sites. Results indicate that changes in microbial abundance in the near-field area of the KAUST SWRO outfall are minor and appear to bethe result of a dilution effect rather than a direct impact of the concentrate discharge. In order to also investigate potential impacts on higher order organisms, a longterm in-situ salinity tolerance test at the discharge site was conducted on the coral Fungia granulosa and its photophysiology. The corals were exposed to elevated levels of salinity as a direct result of concentrate discharge. Their photosynthetic response after exposure to extreme salinity conditions around the full-scale operating SWRO desalination discharge was measured. A pulse amplitude

  15. Experimental study and modelling of X-ray photo-triggering of a discharge for exciplex laser

    Louvet, Yolande

    1986-01-01

    As the excitation of the laser medium by using a photo-triggered discharge revealed to be more reliable that an excitation by pre-ionised discharge, this research thesis reports the use of such an excitation and the study of initiation mechanisms for discharges photo-triggered by X rays. The author first recalls the main characteristics of excimer and exciplex systems, and presents the principle of discharge photo-triggering. He presents the experimental set-up, and reports the use of an original method to characterise the X radiation. This method uses theoretical data related to Bremsstrahlung emission, and results are validated by experimental tests. Realistic data regarding X ray properties are introduced into the theoretical model which also takes X-ray-induced ionisation reactions and photo-electron energetic degradation into account. By using this model, the author determines the electron distribution function produced by the X pre-ionisation, and the resulting thermalized electron density [fr

  16. Studies on laser-assisted Penning ionization by the optogalvanic effect in Ne/Eu hollow cathode discharge.

    Saini, V K; Kumar, P; Dixit, S K; Nakhe, S V

    2015-02-01

    Laser-assisted Penning ionization (LAPI) is detected in a Ne/Eu hollow cathode (HC) discharge lamp using the pulsed optogalvanic (OG) method. In the Ne/Eu discharge, doubly ionized europium excited energy levels Eu[4f(7)(P(7/2,5/2)6)] lie within the thermal limit (∼kT) from the laser-excited neon's energy level [2p(5)(P3/202)3p or 2p(8) (in Paschen notation)] lying at 149,848  cm(-1). Therefore, Penning ionization (PI) of europium atoms likely to occur into its highly excited ionic states is investigated. To probe the PI of europium, the temporal profiles of its counterpart neon OG signal are studied as a function of discharge current for the transitions (1s(4)→2p(8)) and (1s(2)→2p(2)), corresponding to 650.65 and 659.89 nm wavelengths, respectively. It is observed that PI of europium alters the overall discharge characteristics significantly and, hence, modifies the temporal profile of the OG signals accordingly. The quasi-resonant ionizing energy transfer collisions between laser-excited Ne 2p(8) atoms and electronically excited europium P(9/2)10 atoms are used to explain the LAPI mechanism. Such LAPI studies carried out in HC discharge could be useful for the discharge of a metal-vapor laser with appropriate Penning mixtures.

  17. Parameter studies for a two-component fusion experiment

    Towner, H.H.

    1975-01-01

    The sensitivity of the energy multiplication of a two-component fusion experiment is examined relative to the following parameters: energy confinement time (tau/sub E/), particle confinement time (tau/sub p/), effective Z of the plasma (Z/sub eff/), injection rate (j/sub I/) and injection energy (E/sub I/). The Energy Research and Development Administration recently approved funding for such a fusion device (the Toroidal Fusion Test Reactor or TFTR) which will be built at the Princeton Plasma Physics Laboratory. Hence, such a parameter study seems both timely and necessary. This work also serves as an independent check on the design values proposed for the TFTR to enable it to achieve energy breakeven (F = 1). Using the nominal TFTR design parameters and a self-consistent ion-electron power balance, the maximum F-value is found to be approximately 1.2 which occurs at an injection energy of approximately 210 KeV. The injector operation, i.e. its current and energy capability are shown to be a very critical factor in the TFTR performance. However, if the injectors meet the design objectives, there appears to be sufficient latitude in the other parameters to offer reasonable assurance that energy breakeven can be achieved. (U.S.)

  18. Nuclear Criticality Technology and Safety Project parameter study database

    Toffer, H.; Erickson, D.G.; Samuel, T.J.; Pearson, J.S.

    1993-03-01

    A computerized, knowledge-screened, comprehensive database of the nuclear criticality safety documentation has been assembled as part of the Nuclear Criticality Technology and Safety (NCTS) Project. The database is focused on nuclear criticality parameter studies. The database has been computerized using dBASE III Plus and can be used on a personal computer or a workstation. More than 1300 documents have been reviewed by nuclear criticality specialists over the last 5 years to produce over 800 database entries. Nuclear criticality specialists will be able to access the database and retrieve information about topical parameter studies, authors, and chronology. The database places the accumulated knowledge in the nuclear criticality area over the last 50 years at the fingertips of a criticality analyst

  19. Geotechnical parameters for three deep ocean study areas

    Nicholson, D.P.

    1989-01-01

    This chapter summarizes the results of geotechnical measurements made on cores taken at the three deep ocean sites that have been studied in detail as part of the international programme assessing the feasibility of deep ocean disposal of heat-generating radioactive waste. The capabilities of existing sampling methods and the adequacy of the available data for providing the geotechnical parameters needed to evaluate the technical feasibility of deep ocean disposal are discussed. It is concluded that, while it has not been possible to obtain core samples of sufficient quality and depth to provide all the parameters needed for the assessment, no fundamental differences between the sediments at the study areas and those found on land or in shallow water have been identified. (author)

  20. Feasibility of wear compensation in micro EDM milling based on discharge counting and discharge population characterization

    Bissacco, Giuliano; Hansen, Hans Nørgaard; Tristo, G.

    2011-01-01

    This paper investigates the applicability of real time wear compensation in micro EDM milling based on discharge counting and discharge population characterization. Experiments were performed involving discharge counting and tool electrode wear measurement in a wide range of process parameters...

  1. Numerical and experimental study on laminar round free jet of Ar discharging into stagnant air

    Fumizawa, Motoo; Hishida, Makoto; Kunugi, Tomoaki

    1990-01-01

    The objective of the present study is to investigate numerically and experimentally the behavior of the fluid flow and the mass transfer of argon gas (Ar) laminar round jet discharging into stagnant air along the gravity force. The SIMPLE method and two differential numerical schemes of PLDS and QUICK are used in the TEAM code modified by adding the binary diffusion equation. The solution domain is comprised of 80X40 grids of uniform size. As the result, the following were obtained: The half radius of Ar mass fraction obtained by QUICK was in good agreement with experimental result. The half radii of axial velocity and Ar mass fraction obtained by PLDS were larger than those by QUICK due to numerical viscosity. Numerical analyses by PLDS and QUICK schemes agreed well with experimental results on centerline Ar mass fraction. Computational times of PLDS and QUICK are about 40 min. and 120 min. respectively by FACOM VP100 computer in JAERI. (author)

  2. Study of the physical discharge properties of a Ar/O2 DC plasma jet

    Barkhordari, A.; Ganjovi, A.; Mirzaei, I.; Falahat, A.

    2018-03-01

    In this paper, the physical properties of plasma discharge in a manufactured DC plasma jet operating with the Ar/O2 gaseous mixture are studied. Moreover, the optical emission spectroscopy technique is used to perform the experimental measurements. The obtained emission spectra are analyzed and, the plasma density, rotational, vibrational and electronic temperature are calculated. The NO emission lines from {NO }γ( A2 Σ^{+} \\to {X}2 Πr ) electronic transition are observed. It is seen that, at the higher argon contributions in Ar/O2 gaseous mixture, the emission intensities from argon ions will increase. Moreover, while the vibrational and excitation temperatures are increased at the higher input DC currents, they will decrease at the higher Ar percentages in the Ar/O2 gaseous mixture. Furthermore, at the higher DC currents and Ar contributions, both the plasma electron density and dissociation fraction of oxygen atoms are increased.

  3. Experimental study of the pressure discharge process for the hydraulic control rod drive system stepped cylinder

    Wang, Jinhua; Bo, Hanliang; Zheng, Wenxiang

    2002-01-01

    The pressure discharge process from the stepped cylinder of the Hydraulic Control Rod Drive System (HCRDS) was studied experimentally in the HCRDS experimental loop for the 200 MW Nuclear Heating Reactor (NHR-200). The results showed that the differential pressure between the outside and the inside of the stepped cylinder increased rapidly to the desired value so that the force induced by the differential pressure which pushes the out tube of stepped cylinder was large enough. Therefore, if the hydraulic control rod were jammed, the pressure could push the hydraulic control rod to overcome the frictional resistance to insert the control rod into the reactor core. The experimental results verified that this design would solve the problem of hydraulic control rod jamming during an accident. (author)

  4. Study on the plasma reaction process of hydroxyl generation by strong electric field ionization discharge

    Bai Mindi; Deng Shufang; Bai Xiyao; Zhang Zhitao

    2004-01-01

    Considering the change in the structure of reaction room, dielectric materials and process technology, authors have specifically studied the plasma reaction process of creating hydroxyl radical OH * and e aq - from ionization of O 2 and H 2 O through a strong electric field discharge. The production volume of hydroxyl radical OH * is up to the project application level, and process technology meets the 12 laws of green chemistry, free from environmental pollution from the source. The authors have emphatically researched on the green method of flue gas desulfurization, which will ionize SO 2 , H 2 O and O 2 in the flue gas to synthesis H 2 SO 4 in molecular level within 0.8 s without absorbent and catalyst. (author)

  5. Numerical study of the characteristics of a dielectric barrier discharge plasma actuator

    Shi, C. A.; Adamiak, K.; Castle, G. S. P.

    2018-03-01

    A dielectric barrier discharge actuator to control airflow along a flat dielectric plate has been numerically investigated in this paper. In order to avoid large computing times, streamers, Trichel pulses and the ionic reactions involving photons and electrons are neglected. The numerical model assumes two types of generic ions, one positive and one negative, whose drift in the electric field produces the electrohydrodynamic flow. This study provides detailed insights into the physical mechanisms of DBD that include the electric field, space charge transport, surface charge accumulation and air flow motion. The results show the V-I characteristics, velocity profiles and drag force estimates. In addition, the effects of the voltage level, frequency and inlet air velocity on the actuator performance are presented and interpreted. The simulation results show a good agreement with theoretical expectations and experimental data available in literature.

  6. Operational river discharge forecasting in poorly gauged basins: the Kavango River Basin case study

    Bauer-Gottwein, Peter; Jensen, Iris Hedegaard; Guzinski, R.

    2014-01-01

    to support integrated water resources management in Africa and to facilitate the use of satellite earth observation data in water management. We present an operational probabilistic forecasting approach which uses public-domain climate forcing data and a hydrologic–hydrodynamic model which is entirely based......Operational probabilistic forecasts of river discharge are essential for effective water resources management. Many studies have addressed this topic using different approaches ranging from purely statistical black-box approaches to physically-based and distributed modelling schemes employing data...... on open-source software. Data assimilation techniques are used to inform the forecasts with the latest available observations. Forecasts are produced in real time for lead times of 0 to 7 days. The operational probabilistic forecasts are evaluated using a selection of performance statistics and indicators...

  7. Experiences of simulated tracer dispersal studies using effluent discharges at Tarapur aquatic environment

    Sudheendran, V.; Baburajan, A.; Sawane, Pratibha; Rao, D.D.; Hegde, A.G.

    2007-01-01

    The nuclear complex in Tarapur, Maharashtra is a multi facility nuclear site comprising of power reactors and research facilities. Each facility has independent liquid effluent discharge line to Arabian Sea. Experimental studies were conducted to evaluate dilution factors in the aquatic environment using liquid effluent releases as tracer from one of the facilities. 3 H and 137 Cs radioisotopes present in the routine releases were used as simulated tracer nuclides. The dilution factors(D.F) observed for tritium were in the range of 20-20000 in a distance range of 10 m to 1500 m respectively and for 137 Cs the D.F. were in the range of 50 to 900 over a distance range of 10-200 m. The paper describes the analytical methodology and sampling scenarios and the results of dilution factors obtained for Tarapur aquatic environment. (author)

  8. STUDY OF DESTRUCTION PROCESSES OF SYNTHETIC SURFACE-ACTIVE SUBSTENCES (SURFFACTANTS IN BARRIER DISCHARGE

    V.I. Grinevich

    2012-06-01

    Full Text Available Kinetic data of degradation on aqueous solutions of surfactants in the plasma of barrier discharge are presented. The possible mechanism of proceeding processes is offered and considered. It is shown that the treatment in a barrier discharge results in decomposition efficiency of 95%. It is established that the main product of degradation are carboxylic acids.

  9. [Study on the discharge properties of xeon flash lamp and experimental measurement].

    Zhao, You-Quan; Miao, Pei-Liang; He, Feng; Gu, Jian; Zhai, Rui-Wei

    2014-07-01

    The Xenon flash lamp is a new type of light source for analytical instrument. The present paper analyzed the discharge process of xenon flash lamp, presented the discharge test system, and conducted experimental measurement of the voltage, current and optical pulse signal in the process of discharge. The results show that in the preliminary discharge, the free electron concentration was at a low level, so the energy was at a low level, then following the gas discharge, numerous free electrons formed in the lamp, resultin in the increase in the concentration of free electrons, therefore discharge current rised rapidly and voltage reduced. The lamp released photons to generate light pulse in the moment of ionic recombination, The pulse xenon lamp light energy output and spectral characteristic is related to electron energy in recombination and combination level of xenon, if the input energy and the energy consumption of the xenon lamp is inconsistent, it will lead to repeated capacitor charging and discharging and produce oscillation waveform. This paper is very useful for understanding the process of xenon lamp discharge, optimizing the driver circuit and the production of xenon flash lamp.

  10. Baseline studies and evaluation of effects of surface discharge of deep-sea mining - INDEX area

    DeSousa, S.N.; Sardessai, S.

    . An evaluation of possible effects of surface discharge of mining fines - a slurry consisting of fine nodule fragments, bottom water and sediments - suggests that the discharge, with an expected solid content of 50 g/l, will induce increased primary production...

  11. Experimental and computational study of dielectric barrier discharges for environmental applications

    Aerts, Robby

    Air pollution has become a major global concern which affects all inhabitants of our precious earth. Nowadays it is fact that our climate is changing and the sea level is rising. Moreover, we are facing an energy crisis because all our fossil fuel resources will sooner or later be running empty. It is clear that drastic measures are needed to keep our planet as it is today for generations to come. One of these measures is the 20-20-20 targets imposed by the European Commission, which stimulates the research for environmental energy applications. In this PhD dissertation two environmental applications of plasma technology are investigated. The first one is the abatement of flue gases, and more specifically the destruction of volatile organic compounds (VOCs). The second one is the conversion of CO2 into valuable chemicals. Both of these applications suffer from a large energy cost under classical (thermodynamic) conditions, due to the chemical stability of these molecules. Plasma technology is quite promising to overcome these thermodynamic barriers. Plasmas allow reactions at different time-scales with different species, such as electrons, ions, radicals, molecules and excited species, creating new chemical pathways. Indeed, in a plasma the applied electrical energy is directly transferred to the electrons, which activate the gas by ionization, excitation and dissociation, hence creating reactive species (ions, excited species, radicals), that can further easily undergo other chemical reactions. Especially gas discharges, which are low temperature plasmas, show promising results in the destruction of pollutants at mild conditions. A common type of gas discharge is the dielectric barrier discharge (DBD) which has been successfully scaled up for industrial ozone generation and is widely investigated in the field of environmental applications. The complexity of DBDs creates difficulties for experimental diagnostics and therefore numerical studies can help to improve

  12. Exploring challenges in the patient's discharge process from the internal medicine service: A qualitative study of patients' and providers' perceptions.

    Pinelli, Vincent; Stuckey, Heather L; Gonzalo, Jed D

    2017-09-01

    In hospital-based medicine units, patients have a wide range of complex medical conditions, requiring timely and accurate communication between multiple interprofessional providers at the time of discharge. Limited work has investigated the challenges in interprofessional collaboration and communication during the patient discharge process. In this study, authors qualitatively assessed the experiences of internal medicine providers and patients about roles, challenges, and potential solutions in the discharge process, with a phenomenological focus on the process of collaboration. Authors conducted interviews with 87 providers and patients-41 providers in eight focus-groups, 39 providers in individual interviews, and seven individual patient interviews. Provider roles included physicians, nurses, therapists, pharmacists, care coordinators, and social workers. Interviews were audio-recorded and transcribed verbatim, followed by iterative review of transcripts using qualitative coding and content analysis. Participants identified several barriers related to interprofessional collaboration during the discharge process, including systems insufficiencies (e.g., medication reconciliation process, staffing challenges); lack of understanding others' roles (e.g., unclear which provider should be completing the discharge summary); information-communication breakdowns (e.g., inaccurate information communicated to the primary medical team); patient issues (e.g., patient preferences misaligned with recommendations); and poor collaboration processes (e.g., lack of structured interprofessional rounds). These results provide context for targeting improvement in interprofessional collaboration in medicine units during patient discharges. Implementing changes in care delivery processes may increase potential for accurate and timely coordination, thereby improving the quality of care transitions.

  13. Study of surface atmospheric pressure glow discharge plasma based on ultrathin laminated electrodes in air

    Zhao, Luxiang; Liu, Wenzheng; Li, Zhiyi; Ma, Chuanlong

    2018-05-01

    A method to generate large-area surface plasma in air by micro-discharge is proposed. Two ultrathin laminated electrode structures of non-insulating and insulating types were formed by using the nanoscale ITO conductive layer. The surface glow discharge in atmospheric air is realized in low discharge voltage by constructing the special electric field of two-dimensional unidirectional attenuation. In particular, the insulating electrode structure can avoid the loss of ITO electrodes so that the discharge stability can be increased, and the treated objects can be prevented from metal ion pollution caused by the electrode in the discharge. It has broad application prospects in the fields of aerodynamics and material surface treatment.

  14. Study of some physiological parameters among mobile phone users

    Anwar, S.M.; Gabr, S.A.

    2002-01-01

    Forty male mobile users in additional to twenty males as control group similar in age and socio economically matched were chosen for this study. Blood pressure, complete blood picture, five parameters of semen quality and four sex hormones (LH, FSH, prolactin and testosterone)were measured. Elevated significant differences for blood pressure (P<0.01) for the exposed group and some changes in mean values of haematologic parameters, although all values were within the normal range. Minor semen quality and hormonal levels changes between the two groups, including a higher mean follicle-stimulating hormone level; for mobile users (8.10 vs 6.00 mIU/mL), and a slightly higher mean luteinizing hormone level (11.73 vs 10.16 mLU/mL) were noted in the user group

  15. Seismic analysis of steam generator and parameter sensitivity studies

    Qian Hao; Xu Dinggen; Yang Ren'an; Liang Xingyun

    2013-01-01

    Background: The steam generator (SG) serves as the primary means for removing the heat generated within the reactor core and is part of the reactor coolant system (RCS) pressure boundary. Purpose: Seismic analysis in required for SG, whose seismic category is Cat. I. Methods: The analysis model of SG is created with moisture separator assembly and tube bundle assembly herein. The seismic analysis is performed with RCS pipe and Reactor Pressure Vessel (RPV). Results: The seismic stress results of SG are obtained. In addition, parameter sensitivities of seismic analysis results are studied, such as the effect of another SG, support, anti-vibration bars (AVBs), and so on. Our results show that seismic results are sensitive to support and AVBs setting. Conclusions: The guidance and comments on these parameters are summarized for equipment design and analysis, which should be focused on in future new type NPP SG's research and design. (authors)

  16. Numerical Experimentation to Develop Design and Operational Parameters for Skimming Wells: A Case Study of the Chaj Doab of Punjab, Pakistan

    Muhammad Aslam

    2015-07-01

    Full Text Available In the present study, MODFLOW-MT3D groundwater model was employed to perform numerical experimentation to develop design and operational parameters for SW (Skimming Wells based on hydrogeology and groundwater salinity conditions of Chaj Doab, Punjab, Pakistan. Numerical experimentation resulted in: (i a 1-strainer SW with discharge of 14 l/s (litres per second and penetration of 30% resulted in more saltwater upconing at 8 hours/day well operation compared to that occurred at 4 hours/day operation; (ii a 1-strainer well with penetration of 30% and operation of 8 hours/day caused higher saltwater upconing at 14 l/s discharge compared to that at 9 l/s discharge; (iii a 4-strainer well with penetration of 30% and operation of 8 hours/day also caused more saltwater upconing at 14 l/s well discharge compared to that at 9 l/s discharge. Similar trend was found for a 8- strainer well; and (iv 1- or 4- or 8-strainer well with 30-60% penetration, 9-14 l/s discharge and 4-8 hours/day operation could provide pumped groundwater of salinity less than 1000 ppm. Considering hydro-chemical performance and costs of wells, a 4-strainer well with 30% penetration, 9- 14 l/s discharge and 4-8 hours/day operation is recommended to skim groundwater of salinity less than 1000 ppm in Chaj Doab of Punjab, Pakistan

  17. Experimental study of the positive leader velocity as a function of the current in the initial and final-jump phases of a spark discharge

    Andreev, A. G.; Bazelyan, E. M.; Bulatov, M. U.; Kuzhekin, I. P.; Makalsky, L. M.; Sukharevskij, D. I.; Syssoev, V. S.

    2008-01-01

    A positive leader in air at gap lengths of up to 8 m was studied experimentally on an open experimental stand. The voltage source was a 6-MV pulsed voltage generator or an artificial charged aerosol cloud. The dependence of the leader velocity on the current in the range 0.2-8 A was determined by simultaneously recording the optical picture and electric parameters of the discharge. Particular attention was paid to the final-jump phase of the discharge, when the gap was completely bridged by the streamer zone of the leader. It is shown that the character of the dependence of the leader velocity on the current in this phase remains unchanged; hence, the final-jump phase can be used in experiments in which the current has to be varied within a wide range. For this purpose, one can use a damping resistance, which is inefficient in the initial phase. The parameters of the power-law dependence of the leader velocity on the current at currents of a few amperes are established reliably. It is found that the power-law dependence with constant parameters is inapplicable to calculate the leader velocity at currents of about 0.1 A, which correspond to the lower limit of the leader viability.

  18. POPULATION SYNTHESIS OF HOT SUBDWARFS: A PARAMETER STUDY

    Clausen, Drew; Wade, Richard A.; Kopparapu, Ravi Kumar; O'Shaughnessy, Richard

    2012-01-01

    Binaries that contain a hot subdwarf (sdB) star and a main-sequence companion may have interacted in the past. This binary population has historically helped determine our understanding of binary stellar evolution. We have computed a grid of binary population synthesis models using different assumptions about the minimum core mass for helium ignition, the envelope binding energy, the common-envelope ejection efficiency, the amount of mass and angular momentum lost during stable mass transfer, and the criteria for stable mass transfer on the red giant branch and in the Hertzsprung gap. These parameters separately and together can significantly change the entire predicted population of sdBs. Nonetheless, several different parameter sets can reproduce the observed subpopulation of sdB + white dwarf and sdB + M dwarf binaries, which has been used to constrain these parameters in previous studies. The period distribution of sdB + early F dwarf binaries offers a better test of different mass transfer scenarios for stars that fill their Roche lobes on the red giant branch.

  19. Study of Temperature Coefficients for Parameters of Photovoltaic Cells

    Daniel Tudor Cotfas

    2018-01-01

    Full Text Available The temperature is one of the most important factors which affect the performance of the photovoltaic cells and panels along with the irradiance. The current voltage characteristics, I-V, are measured at different temperatures from 25°C to 87°C and at different illumination levels from 400 to 1000 W/m2, because there are locations where the upper limit of the photovoltaic cells working temperature exceeds 80°C. This study reports the influence of the temperature and the irradiance on the important parameters of four commercial photovoltaic cell types: monocrystalline silicon—mSi, polycrystalline silicon—pSi, amorphous silicon—aSi, and multijunction InGaP/InGaAs/Ge (Emcore. The absolute and normalized temperature coefficients are determined and compared with their values from the related literature. The variation of the absolute temperature coefficient function of the irradiance and its significance to accurately determine the important parameters of the photovoltaic cells are also presented. The analysis is made on different types of photovoltaics cells in order to understand the effects of technology on temperature coefficients. The comparison between the open-circuit voltage and short-circuit current was also performed, calculated using the temperature coefficients, determined, and measured, in various conditions. The measurements are realized using the SolarLab system, and the photovoltaic cell parameters are determined and compared using the LabVIEW software created for SolarLab system.

  20. Runaway electron studies with hard x-ray and microwave diagnostics in the FT-2 lower hybrid current drive discharges

    Shevelev, A. E.; Khilkevitch, E. M.; Lashkul, S. I.; Rozhdestvensky, V. V.; Pandya, S. P.; Plyusnin, V. V.; Altukhov, A. B.; Kouprienko, D. V.; Chugunov, I. N.; Doinikov, D. N.; Esipov, L. A.; Gin, D. B.; Iliasova, M. V.; Naidenov, V. O.; Polunovsky, I. A.; Sidorov, A. V.; Kiptily, V. G.

    2018-01-01

    Studies of the super-thermal and runaway electron behavior in ohmic and lower hybrid current drive FT-2 tokamak plasmas have been carried out using information obtained from measurements of hard x-ray spectra and non-thermal microwave radiation intensity at the frequency of 10 GHz and in the range of (53 ÷ 78) GHz. A gamma-ray spectrometer based on a scintillation detector with a LaBr3(Ce) crystal was used, which provides measurements at counting rates up to 107 s-1. Reconstruction of the energy distribution of RE interacting with the poloidal limiter of the tokamak chamber was made with application of the DeGaSum code. Super-thermal electrons accelerated up to 2 MeV by the LH waves at the high-frequency pumping of the plasma with low density ≤ft ~ 2  ×  1013 cm-3 and then up to 7 MeV by vortex electric field have been found. Experimental analysis of the runaway electron beam generation and evolution of their energy distribution in the FT-2 plasmas is presented in the article and compared with the numerical calculation of the maximum energy gained by runaway electrons for given plasma parameters. In addition, possible mechanisms for limiting the maximum energy gained by the runaway electrons are also calculated and described for a FT-2 plasma discharge.

  1. LASERS: Parameters of a trigatron-driven low-pulse-repetition-rate TEA CO2 laser preionised by a surface corona discharge

    Aram, M.; Behjat, A.; Shabanzadeh, M.; Mansori, F.

    2007-01-01

    The design of a TEA CO2 laser with UV preionisation by a surface corona discharge is described and the dependences of its average output energy on the gas-flow rate, discharge voltage and pulse repetition rate are presented. The scheme of the electric circuit and the geometry of the pre-ionisation system are considered. The electric circuit is designed to produce only impulse voltage difference between the laser electrodes. The triggering system of the trigatron is used to prevent the appearance of the arc. The dependences of the current, voltage and average output energy on the gas-mixture composition and applied voltages at a low pulse repetition rate are presented. The central output wavelength of the laser was measured with an IR spectrometer. Lasing at two adjacent vibrational-rotational transitions of the CO2 molecule was observed, which demonstrates the possibility of simultaneous lasing at several lines.

  2. Parameters of a trigatron-driven low-pulse-repetition-rate TEA CO2 laser preionised by a surface corona discharge

    Aram, M; Shabanzadeh, M; Mansori, F; Behjat, A

    2007-01-01

    The design of a TEA CO 2 laser with UV preionisation by a surface corona discharge is described and the dependences of its average output energy on the gas-flow rate, discharge voltage and pulse repetition rate are presented. The scheme of the electric circuit and the geometry of the pre-ionisation system are considered. The electric circuit is designed to produce only impulse voltage difference between the laser electrodes. The triggering system of the trigatron is used to prevent the appearance of the arc. The dependences of the current, voltage and average output energy on the gas-mixture composition and applied voltages at a low pulse repetition rate are presented. The central output wavelength of the laser was measured with an IR spectrometer. Lasing at two adjacent vibrational-rotational transitions of the CO 2 molecule was observed, which demonstrates the possibility of simultaneous lasing at several lines. (lasers)

  3. Microwave Photocatalysis IV: Effects of Additional Operational Parameters on the Microwave Photocatalytic Degradation of Mono-Chloroacetic Acid Using Titania-Coated Mercury Electrodeless Discharge Lamps

    Kmentová, Hana; Církva, Vladimír

    2013-01-01

    Roč. 88, č. 6 (2013), s. 1109-1113 ISSN 0268-2575 R&D Projects: GA ČR GA104/07/1212; GA ČR GD203/08/H032 Institutional support: RVO:67985858 Keywords : microwave photocatalysis * titania thin film * mercury electrodeless discharge lamp Subject RIV: CH - Nuclear ; Quantum Chemistry Impact factor: 2.494, year: 2013

  4. Assessment of inpatient psychiatric readmission risk among patients discharged on an antipsychotic polypharmacy regimen: A retrospective cohort study.

    Boskailo, Esad; Malkoc, Aldin; McCurry, Dustin B; Venter, Jacob; Drachman, David; Ramos, Gilbert M

    2017-11-01

    Patients are frequently prescribed multiple antipsychotic medications, leading to higher healthcare costs and increased risk for side effects. The efficacy of multiple versus single antipsychotics to prevent acute relapse, measured by incidence of inpatient readmission, is investigated in Arizona, USA. A retrospective chart review compared socio-demographic and clinical data from 1,010 patients discharged on a single and 377 discharged on multiple antipsychotic medications. Case management records were reviewed for readmission within one year of discharge. Younger age, diagnosis of Schizophrenia or Schizoaffective Disorder, prescription of mood stabilizer, shorter length of stay, and discharge to residential treatment or crisis recovery unit were associated with multiple antipsychotics at discharge. Readmission rates of the single (13.7%) versus multiple (15.9%) antipsychotic groups were not statistically different (p=0.286). Logistic regression analysis established that only age (younger) and the prescription of a mood stabilizer at discharge were significant predictors for increased risk for readmission (p=0.010 and p=0.049, respectively). A Cox survival analysis supported these findings. Concomitant antipsychotic polypharmacy at discharge did not reduce readmission risk over a one-year period. Given the increased risk of side effects and financial costs of polypharmacy, this study did not provide evidence to support this practice. Strikingly, only two variables predicted readmission risk, younger age and prescription of mood stabilizer. Although practitioners should follow practice guidelines more closely to prevent unnecessary exposure to potentially lethal side effects of antipsychotic polypharmacy, further studies are needed to better identify patients at high risk for readmission. Copyright © 2017 by Academy of Sciences and Arts of Bosnia and Herzegovina.

  5. Medication details documented on hospital discharge: cross-sectional observational study of factors associated with medication non-reconciliation.

    Grimes, Tamasine C

    2012-02-01

    AIMS: Movement into or out of hospital is a vulnerable period for medication safety. Reconciling the medication a patient is using before admission with the medication prescribed on discharge, and documenting any changes (medication reconciliation) is recommended to improve safety. The aims of the study were to investigate the factors contributing to medication reconciliation on discharge, and identify the prevalence of non-reconciliation. METHODS: The study was a cross-sectional, observational survey using consecutive discharges from purposively selected services in two acute public hospitals in Ireland. Medication reconciliation, potential for harm and unplanned re-admission were investigated. RESULTS: Medication non-reconciliation was identified in 50% of 1245 inpatient episodes, involving 16% of 9569 medications. The majority of non-reconciled episodes had potential to result in moderate (63%) or severe (2%) harm. Handwritten rather than computerized discharges (adjusted odds ratio (adjusted OR) 1.60, 95% CI 1.11, 2.99), increasing number of medications (adjusted OR 1.26, 95% CI 1.21, 1.31) or chronic illness (adjusted OR 2.08, 95% CI 1.33, 3.24) were associated with non-reconciliation. Omission of endocrine, central nervous system and nutrition and blood drugs was more likely on discharge, whilst omission on admission and throughout inpatient care, without documentation, was more likely for obstetric, gynaecology and urinary tract (OGU) or respiratory drugs. Documentation in the discharge communication that medication was intentionally stopped during inpatient care was less likely for cardiovascular, musculoskeletal and OGU drugs. Errors involving the dose were most likely for respiratory drugs. CONCLUSIONS: The findings inform strategies to facilitate medication reconciliation on discharge from acute hospital care.

  6. Identification of ballast water discharge profiles of a port to enable effective ballast water management and environmental studies

    David, Matej; Gollasch, Stephan; Penko, Ludvik

    2018-03-01

    Information about the profile of ballast water discharges in a port is one of the basic elements of the decision making process in ballast water risk assessment and management, and supports the evaluation of dimensions and processes of aquatic species invasions with vessels ballast water. In the lack of ballast water reporting, ballast water discharge assessments need to be conducted. In this study we have assessed and compared ballast water discharge profiles of two ports with different maritime traffic and cargo profiles, the Port of Hamburg (Germany) and the Muuga Harbour, Port of Tallinn (Estonia). This study shows methods and approaches which can be used to assess volumes and donor ports of ballast water discharges for a port at the level of each vessel call. These methods and approaches can be applied to any port to support the implementation of feasible and efficient ballast water management measures and to enable environmental studies including long-term accumulation risks of disinfection by-products from ballast water management systems making use of active substances, as well as for discharges of other chemical compounds.

  7. Aspartame exacerbates EEG spike-wave discharge in children with generalized absence epilepsy: a double-blind controlled study.

    Camfield, P R; Camfield, C S; Dooley, J M; Gordon, K; Jollymore, S; Weaver, D F

    1992-05-01

    There are anecdotal reports of increased seizures in humans after ingestion of aspartame. We studied 10 children with newly diagnosed but untreated generalized absence seizures. Ambulatory cassette recording of EEG allowed quantification of numbers and length of spike-wave discharges in a double-blind study on two consecutive days. On one day the children received 40 mg/kg aspartame and on the other day, a sucrose-sweetened drink. Baseline EEG was the same before aspartame and sucrose. Following aspartame compared with sucrose, the number of spike-wave discharges per hour and mean length of spike-wave discharges increased but not to a statistically significant degree. However, the total duration of spike-wave discharge per hour was significantly increased after aspartame (p = 0.028), with a 40% +/- 17% (SEM) increase in the number of seconds per hour of EEG recording that the children spent in spike-wave discharge. Aspartame appears to exacerbate the amount of EEG spike wave in children with absence seizures. Further studies are needed to establish if this effect occurs at lower doses and in other seizure types.

  8. Discharges from nuclear power stations

    1991-02-01

    HM Inspectorate of Pollution commissioned, with authorising responsibilities in England and Wales, a study into the discharges of radioactive effluents from Nuclear Power Stations. The study considered arisings from nuclear power stations in Europe and the USA and the technologies to treat and control the radioactive discharges. This report contains details of the technologies used at many nuclear power stations to treat and control radioactive discharges and gives, where information was available, details of discharges and authorised discharge limits. (author)

  9. Experimental study of a fast plasma focus discharge operated in the range of tens of joules emitting neutrons

    Tarifeno Saldivia, Eriel Esteban

    2011-01-01

    In this doctoral research, a small plasma focus discharge operated at tens of joules and kilo amperes has been experimentally studied. This device produces a coaxial discharge by an electrode arrange which consists of an inner electrode, a cylindrical insulator, and an outer electrode. The discharge is driven by a capacitive generator and it is operated at pressures of some millibars. Typical electrical parameters of the device are T/4∼150ns, 160 nF, 40 nH, 30-100J, 40-70kA. When Deuterium is used as filling gas, neutrons are produced by fusion reactions. The device, namely PF-50J, is one of the most extreme plasma focus reported in the literature to emit neutrons. The results of this work have demonstrated that the same dynamics found in larger machines (operated from kJ to MJ) is also found in this extremely low energy device which means that after the discharge is initiated, a plasma sheet is formed over the insulator. By the action of the Lorentz force, the plasma sheet moves axially. When the sheet reaches the top end of the inner electrode, it starts to implode radially to finally form a dense plasma column (pinch). Finally, the plasma column is disrupted 5-10ns after column formation. Shock piston velocities of the order of 10 4 -10 5 m/s were estimated from experiments for each discharge dynamical phase. Typical pinch densities of 10 24-25 m -3 were also observed in PF-50J. An interesting feature observed in this work is the formation of axial jet-like structures which appears at late times almost hundred nanoseconds after pinch disruption. These structures are composed by a metallic plasma which results from ablation of the inner electrode. The mechanism responsible for the formation of this kind of structure is still unknown, although evidence suggests that the phenomena is not related to the pinch formation process. One of the principal motivations of this thesis was to study the optimization for neutron emission in the PF-50J device. This plasma focus

  10. Study on parameter identification and control of ground temperature

    Kojima, Keiichi; Suzuki, Seiichi; Kawahara, Mutsuto.

    1995-01-01

    A numerical thermal management system for ground structure is presented. The system consists of two parts, i.e. the identification analysis of the thermal conductivity and the thermal control analysis for the ground. The former is carried out by using the nonlinear least squares method and the latter is based on the optimal control theory. The formulations of these methods are presented and they are applied to an laboratory test. A reasonable thermal conductivity of the ground is identified by parameter estimation method and the ground temperature is actually controled as illustrated by numerical and experimental study. (author)

  11. Studying the noise parameters of thin-film silicon resistors

    Belogurov, S.V.; Gostilo, V.V.; Yurov, A.S.

    1986-01-01

    The results of studies on spectral density and energy noise equivalent of thin-film resistors on the base of amorphous silicon and KIM and KVM commercial high-ohmic resistors are presented. Dependence of the active part of impedance on frequency is shown to be the main source of redundant noise in resistors. Dependence of spectral density of noise voltage of current noises of silicon resistors on applied voltage is described by the formula S T =B V 2 /f 1.6 with the values B=(1.4-1.7)x10 -12 Hz 0.6 . As to noise parameters the silicon resistor is superior to commercial resistors

  12. Study of nuclear level density parameter and its temperature dependence

    Nasrabadi, M. N.; Behkami, A. N.

    2000-01-01

    The nuclear level density ρ is the basic ingredient required for theoretical studies of nuclear reaction and structure. It describes the statistical nuclear properties and is expressed as a function of various constants of motion such as number of particles, excitation energy and angular momentum. In this work the energy and spin dependence of nuclear level density will be presented and discussed. In addition the level density parameter α will be extracted from this level density information, and its temperature and mass dependence will be obtained

  13. Characterizing parameters of Jatropha curcas cell cultures for microgravity studies

    Vendrame, Wagner A.; Pinares, Ania

    2013-06-01

    Jatropha (Jatropha curcas) is a tropical perennial species identified as a potential biofuel crop. The oil is of excellent quality and it has been successfully tested as biodiesel and in jet fuel mixes. However, studies on breeding and genetic improvement of jatropha are limited. Space offers a unique environment for experiments aiming at the assessment of mutations and differential gene expression of crops and in vitro cultures of plants are convenient for studies of genetic variation as affected by microgravity. However, before microgravity studies can be successfully performed, pre-flight experiments are necessary to characterize plant material and validate flight hardware environmental conditions. Such preliminary studies set the ground for subsequent spaceflight experiments. The objectives of this study were to compare the in vitro growth of cultures from three explant sources (cotyledon, leaf, and stem sections) of three jatropha accessions (Brazil, India, and Tanzania) outside and inside the petriGAP, a modified group activation pack (GAP) flight hardware to fit petri dishes. In vitro jatropha cell cultures were established in petri dishes containing a modified MS medium and maintained in a plant growth chamber at 25 ± 2 °C in the dark. Parameters evaluated were surface area of the explant tissue (A), fresh weight (FW), and dry weight (DW) for a period of 12 weeks. Growth was observed for cultures from all accessions at week 12, including subsequent plantlet regeneration. For all accessions differences in A, FW and DW were observed for inside vs. outside the PetriGAPs. Growth parameters were affected by accession (genotype), explant type, and environment. The type of explant influenced the type of cell growth and subsequent plantlet regeneration capacity. However, overall cell growth showed no abnormalities. The present study demonstrated that jatropha in vitro cell cultures are suitable for growth inside PetriGAPs for a period of 12 weeks. The parameters

  14. NIPPLE DISCHARGE

    T. N. Bukharova

    2008-01-01

    Full Text Available According to the data available in the literature, as high as 50% of women have benign breast tumors frequently accompanied by nip- ple discharge. Nipple discharge may be serous, bloody, purulent, and colostric. The most common causes are breast abscess, injury, drugs, prolactinoma, intraductal pappiloma, ductal ectasia, intraductal cancer (not more than 10%.

  15. Epidemiology of Endometriosis in France: A Large, Nation-Wide Study Based on Hospital Discharge Data

    Peter von Theobald

    2016-01-01

    Full Text Available We aimed to assess the prevalence of hospitalization for endometriosis in the general population in France and in each French region and to describe temporal trends, rehospitalization rates, and prevalence of the different types of endometriosis. The analyses were carried out on French hospital discharge data and covered the period 2008–2012 and a population of 14,239,197 women of childbearing age. In this population, the prevalence of hospitalization for endometriosis was 0.9%, ranging from 0.4% to 1.6% between regions. Endometriosis affected 1.5% of hospitalized women of childbearing age, ranging from 1.0% to 2.4% between regions. The number of patients hospitalized for endometriosis significantly increased over the study period (p<0.01. Of these, 4.2% were rehospitalized at least once at one year: ranging from 2.7% to 6.3% between regions. The cumulative rehospitalization rate at 3 years was 6.9%. The types of endometriosis according to the procedures performed were as follows: ovarian (40–50%, peritoneal (20–30%, intestinal (10–20%, and ureteral or bladder (<10%, with significant differences between regions. This is the first detailed epidemiological study of endometriosis in France. Further studies are needed to assess the reasons for the increasing prevalence of endometriosis and for the significant differences in regional prevalence of this disease.

  16. A study of coherent radiation generated in an ablative capillary discharge

    Hübner, Jakub; Vrba, Pavel

    2013-01-01

    Roč. 53, č. 2 (2013), s. 79-87 ISSN 1210-2709 R&D Projects: GA ČR GAP102/12/2043 Institutional support: RVO:61389021 Keywords : capillary discharge * XUV or soft X-ray laser * plasma modeling * ablation Subject RIV: BL - Plasma and Gas Discharge Physics https://ojs.cvut.cz/ojs/index.php/ap/article/view/1787/1619

  17. A pilot study to investigate the impacts of agro-food discharges on a domestic WWTP

    Fernandez, F. J.; Villasenor, J.; Rodriguez, L.

    2009-01-01

    The approval of Directive 91/271CE, which limits the concentration of nutrients (N and P) in treated wastewater discharges, has led to majority of WWTP in Europe to work with nutrient removal processes. These WWTP for BNR are usually optimized to remove nutrients for domestic wastewater, but in some cases a significant discharge of industrial wastewater can modify the influent wastewater composition. (Author)

  18. Parameter uncertainty in simulations of extreme precipitation and attribution studies.

    Timmermans, B.; Collins, W. D.; O'Brien, T. A.; Risser, M. D.

    2017-12-01

    The attribution of extreme weather events, such as heavy rainfall, to anthropogenic influence involves the analysis of their probability in simulations of climate. The climate models used however, such as the Community Atmosphere Model (CAM), employ approximate physics that gives rise to "parameter uncertainty"—uncertainty about the most accurate or optimal values of numerical parameters within the model. In particular, approximate parameterisations for convective processes are well known to be influential in the simulation of precipitation extremes. Towards examining the impact of this source of uncertainty on attribution studies, we investigate the importance of components—through their associated tuning parameters—of parameterisations relating to deep and shallow convection, and cloud and aerosol microphysics in CAM. We hypothesise that as numerical resolution is increased the change in proportion of variance induced by perturbed parameters associated with the respective components is consistent with the decreasing applicability of the underlying hydrostatic assumptions. For example, that the relative influence of deep convection should diminish as resolution approaches that where convection can be resolved numerically ( 10 km). We quantify the relationship between the relative proportion of variance induced and numerical resolution by conducting computer experiments that examine precipitation extremes over the contiguous U.S. In order to mitigate the enormous computational burden of running ensembles of long climate simulations, we use variable-resolution CAM and employ both extreme value theory and surrogate modelling techniques ("emulators"). We discuss the implications of the relationship between parameterised convective processes and resolution both in the context of attribution studies and progression towards models that fully resolve convection.

  19. A pulsed oxygen - iodine chemical laser excited by a longitudinal electric discharge

    Vagin, Nikolai P; Yuryshev, Nikolai N

    2002-01-01

    The dependence of the energy parameters of an oxygen - iodine chemical laser with a bulk generation of iodine atoms in a longitudinal electric discharge on the length of the discharge gap is studied for various discharge energies and voltages and various working mixture compositions (at constant oxygen and iodine pressures). Analyses of the results suggests that temperature effects account for a twofold decrease in the specific energy yield for the lasing initiated by a longitudinal electric discharge compared to the photolytic initiation. (lasers)

  20. Pilot Study on Early Postoperative Discharge in Pituitary Adenoma Patients: Effect of Socioeconomic Factors and Benefit of Specialized Pituitary Centers.

    Sarkiss, Christopher A; Lee, James; Papin, Joseph A; Geer, Eliza B; Banik, Rudrani; Rucker, Janet C; Oudheusden, Barbara; Govindaraj, Satish; Shrivastava, Raj K

    2015-08-01

    Introduction Pituitary neoplasms are benign entities that require distinct diagnostic and treatment considerations. Recent advances in endoscopic transsphenoidal surgery have resulted in shorter lengths of stay (LOS). We implemented a postoperative day (POD) 1 discharge paradigm involving a multidisciplinary approach and detailed preoperative evaluation and review of both medical and socioeconomic factors. Methods The experience of a single neurosurgeon/ears, nose, throat (ENT) team was reviewed, generating a preliminary retrospective database of the first 30 patients who underwent resection of pituitary lesions under the POD 1 discharge paradigm. We assessed multiple axes from their preoperative, in-house, and postoperative care. Results There were 14 men and 16 women with an average age of 53.8 years (range: 27-76 years). There were 22 nonsecretory and 8 secretory tumors with average size of 2.80 cm (range: 1.3-5.0 cm). All 30 patients underwent preoperative ENT evaluation. Average LOS was 1.5 ± 0.7 days. A total of 18 of 30 patients were discharged on POD 1. The insurance status included 15 with public insurance such as emergency Medicaid and 15 with private insurance. Four patients had transient diabetes insipidus (DI); none had permanent DI. Overall, 28 of 30 patients received postoperative steroids. Factors that contributed to LOS > 1 day included public insurance status, two or more medical comorbidities, diabetes mellitus, transient panhypopituitarism, and DI. Conclusion The implementation of a POD 1 discharge plan for pituitary tumors is feasible and safe for elective patients. This implementation requires the establishment of a dedicated Pituitary Center model with experienced team members. The consistent limitation to early discharge was socioeconomic status. Efforts that incorporate the analysis of social disposition parameters with proper management of clinical sequelae are crucial to the maintenance of ideal LOS and optimal patient

  1. Effect of Micro Electrical Discharge Machining Process Conditions on Tool Wear Characteristics: Results of an Analytic Study

    Puthumana, Govindan; P., Rajeev

    2016-01-01

    Micro electrical discharge machining is one of the established techniques to manufacture high aspect ratio features on electrically conductive materials. This paper presents the results and inferences of an analytical study for estimating theeffect of process conditions on tool electrode wear...... characteristicsin micro-EDM process. A new approach with two novel factors anticipated to directly control the material removal mechanism from the tool electrode are proposed; using discharge energyfactor (DEf) and dielectric flushing factor (DFf). The results showed that the correlation between the tool wear rate...... (TWR) and the factors is poor. Thus, individual effects of each factor on TWR are analyzed. The factors selected for the study of individual effects are pulse on-time, discharge peak current, gap voltage and gap flushing pressure. The tool wear rate decreases linearly with an increase in the pulse on...

  2. A pilot study to monitor changes in spirometry and lung volume, following an exacerbation of Chronic Obstructive Pulmonary Disease (COPD), as part of a supported discharge program.

    Cushen, Breda; McCormack, Niamh; Hennigan, Kerrie; Sulaiman, Imran; Costello, Richard W; Deering, Brenda

    2016-10-01

    One-third of patients with an exacerbation of Chronic Obstructive Pulmonary Disease(COPD) are re-hospitalised at 90 days. Exacerbation recovery is associated with reductions in lung hyperinflation and improvements in symptoms and physical activity. We assessed the feasibility of monitoring these clinical parameters in the home. We hypothesised that the degree of change in spirometry and lung volumes differs between those who had an uneventful recovery and those who experienced a further exacerbation. Hospitalised patients with an acute exacerbation of COPD referred for a supported discharge program participated in the study. Spirometry and Inspiratory Vital Capacity(IVC) were measured in the home at Days 1, 14 and 42 post-discharge. Patients also completed Medical Research Council(MRC), Borg and COPD Assessment Test(CAT) scores and were provided with a tri-axial accelerometer. Any new exacerbation events were recorded. Sixty-five patients with 72 exacerbation episodes were recruited. Fifty percent experienced a second exacerbation. Adequate IVC measurements were achieved by 90%, while only 70% completed spirometry. Uneventful recovery was accompanied by significant improvements in physiological measurements at day14, improved symptom scores and step count, p volumes, symptoms and step count following a COPD exacerbation may help to identify patients at risk of re-exacerbation. It is feasible to carry out these assessments in the home as part of a supported discharge programme. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Pediatrician’s perspectives on discharge against medical advice (DAMA among pediatric patients: a qualitative study

    Macrohon Bernadette C

    2012-06-01

    Full Text Available Abstract Background The phenomenon of discharge against medical advice (DAMA among pediatric patients places pediatricians in a dilemma between respect for the parent’s decision and the desire to provide complete care for the vulnerable child-patient. Little has been written about factors that affect a pediatrician’s decision to allow a parent to discharge his child against medical advice. This qualitative study aims to answer the question of how pediatric residents in a tertiary government hospital perceive and decide on a DAMA request from a parent or primary caregiver. Methods Using a focus group discussion approach, 11 pediatric residents from a government-run tertiary hospital were recruited for the study. The session was digitally recorded and dominant themes were coded and identified. Results There were three prominent themes that arose in the discussion: variability of definitions of DAMA, factors considered before “allowing” the patient to be DAMA, and the implications of a DAMA request on their performance as pediatricians. Definitions vary from one resident to another based on the main reason for DAMA (terminal, cultural, or financial. A conflict was noted in the definition of Home per Request (HPR versus DAMA. Factors that influence a pediatrician to sign out a case as DAMA include: their ability to do something about the reason given for the DAMA request, the condition of the patient when the DAMA request was given, their impression of the kind of care that the parents provide, and their legal liabilities. Pediatric residents generally maintain a positive attitude towards the parents who request for DAMA and in the event of readmission, accept the patient into their care again. The occurrence of a variety of definitions and subcategories for DAMA may cause confusion among the pediatricians and should be clarified. The familiarity with cultural traditions contributes to their ability to handle situations that may lead to DAMA

  4. Study of some parameters of the fibrinogen - fibrin transformation reaction

    Hollard, D.; Suscillon, M.; Marcille, G.; Rambaud, F.; Baloyan, M.

    1966-01-01

    The authors studied the action of some parameters on the reaction of transformation fibrinogen-fibrin. The five parameters studied are: the concentration of substratum: a certain quantity of enzyme determines an optimum quantity of fibrinogen; the concentration of enzyme: a certain quantity of substratum defines an optimum quantity of enzyme, beyond which the excess of enzyme is unable to act, the substratum being saturated by the enzyme; the concentration of Ca ions: between 0,07 and 0,10 mg of Ca by mg of fibrinogen, the reaction appears with a great speed. Between 0,02 and 0,40 mg of Ca by mg of fibrinogen the fibrin stabilisation is possible, the FSF can act only inside the definite bounds; the ph of the solution: the reaction of the transformation appears with its maximum intensity on physiological ph, the polymerisation is not possible on acid ph; the temperature has an effect which could not really be verified owing to the fact that the technical realisation is difficult. (author) [fr

  5. Study of carbon dioxide gas treatment based on equations of kinetics in plasma discharge reactor

    Abedi-Varaki, Mehdi

    2017-08-01

    Carbon dioxide (CO2) as the primary greenhouse gas, is the main pollutant that is warming earth. CO2 is widely emitted through the cars, planes, power plants and other human activities that involve the burning of fossil fuels (coal, natural gas and oil). Thus, there is a need to develop some method to reduce CO2 emission. To this end, this study investigates the behavior of CO2 in dielectric barrier discharge (DBD) plasma reactor. The behavior of different species and their reaction rates are studied using a zero-dimensional model based on equations of kinetics inside plasma reactor. The results show that the plasma reactor has an effective reduction on the CO2 density inside the reactor. As a result of reduction in the temporal variations of reaction rate, the speed of chemical reactions for CO2 decreases and very low concentration of CO2 molecules inside the plasma reactor is generated. The obtained results are compared with the existing experimental and simulation findings in the literature.

  6. Behaviour of OH radicals in an atmospheric-pressure streamer discharge studied by two-dimensional numerical simulation

    Komuro, Atsushi; Ono, Ryo; Oda, Tetsuji

    2013-01-01

    The production process of OH radicals in an atmospheric-pressure streamer discharge is studied. A streamer discharge model is developed to analyse the characteristics of a pulsed positive streamer discharge in point-to-plane electrodes filled with humid air at atmospheric pressure. The results indicate that the behaviour of OH radicals in and after the discharge pulse is characterized by three reaction processes: ‘OH-production’, ‘OH-cycle’ and ‘OH-recombination’. The first process of OH-production includes dissociation reactions of H 2 O with O( 1 D) and N 2 (a' 1 Σ u - ), which are the main production processes of OH in the discharge. Immediately after the OH-production process, the OH radicals are destroyed by a reaction with O( 3 P) to form O 2 and H. Then the subsequent reactions produce OH again through the reaction of H + HO 2 , which is the OH-cycle process. Finally, the OH radicals are consumed by the OH-recombination process. (paper)

  7. Using radon-222 for tracing groundwater discharge into an open-pit lignite mining lake--a case study.

    Schmidt, Axel; Schubert, Michael

    2007-12-01

    Groundwater discharge into an open pit lignite mining lake was investigated using radon-222 as a naturally occurring environmental tracer. The chosen study site was a meromictic lake, i.e., a water body that is divided horizontally into two separate layers--the upper mixolimnion (with seasonal mixing) and the lower monimolimnion (without seasonal mixing). For the estimation of groundwater discharge rates into the lake, a simple box model including all radon sinks and sources related to each layer was applied. Two field investigations were performed. During the October campaign, the total groundwater discharge into the lake was found to be 18.9 and 0.7 m(3) d(-1) for the mixolimnion and monimolimnion, respectively. During the December campaign, the groundwater discharge into the mixolimnion was 15.0 m(3) d(-1), whereas no discharge at all was observed into the monimolimnion. Based on the given water volumes, the residence time of lake water was 5.3 years for the monimolimnion and varies between 0.9 and 1.1 years for the mixolimnion. The investigation confirmed radon to be a useful environmental tracer for groundwater and surface water interactions in meromictic lake environments.

  8. Avaliation between precocious out of bed in the intensive care unit and functionality after discharge: a pilot study

    Taciana Guterres de Carvalho

    2013-07-01

    Full Text Available Backgound and Objectives: The incidence of complications arising from the deleterious effects of immobility in the intensive care unit contributes to functional decline, increased length of hospital stay and reduced functionality. Physical therapy is able to promote recovery and preservation of functionality, which can minimize these complications - through early mobilization. To evaluate the functionality and independence of patients who underwent a early bed output in the Intensive Care Unit. Methods: A randomized controlled clinical trial was conducted with patients admitted to the Intensive Care Unit (ICU of the Santa Cruz Hospital and having a physiotherapy prescription. The patients were divided into conventional therapy group- control group and intervention group, who performed the protocol of early mobilization, promoting the bed output. The functionality was measured three times (retroactive to hospitalization, at discharge from the ICU and on hospital discharge through the instrument Functional Independence Measure (FIM. Results: Preliminary data indicates that the intervention group (n = 4 presented lower loss of functionality after discharge from the ICU, with a deficit of 19%, having recovered until the hospital discharge 97% of the prehospitalization measure. The control group (n = 5 showed higher loss in the ICU of 47.6%, and was discharged from hospital with only 72% of their basal rate. Conclusion: There was a lower loss rate and better recovery of functionality in the studied population when those were submitted to a systematized and early protocol of mobilization as well as shorter hospital stay.

  9. Study on Parameters Modeling of Wind Turbines Using SCADA Data

    Yonglong YAN

    2014-08-01

    Full Text Available Taking the advantage of the current massive monitoring data from Supervisory Control and Data Acquisition (SCADA system of wind farm, it is of important significance for anomaly detection, early warning and fault diagnosis to build the data model of state parameters of wind turbines (WTs. The operational conditions and the relationships between the state parameters of wind turbines are complex. It is difficult to establish the model of state parameter accurately, and the modeling method of state parameters of wind turbines considering parameter selection is proposed. Firstly, by analyzing the characteristic of SCADA data, a reasonable range of data and monitoring parameters are chosen. Secondly, neural network algorithm is adapted, and the selection method of input parameters in the model is presented. Generator bearing temperature and cooling air temperature are regarded as target parameters, and the two models are built and input parameters of the models are selected, respectively. Finally, the parameter selection method in this paper and the method using genetic algorithm-partial least square (GA-PLS are analyzed comparatively, and the results show that the proposed methods are correct and effective. Furthermore, the modeling of two parameters illustrate that the method in this paper can applied to other state parameters of wind turbines.

  10. Study on characteristics of high frequency dielectric barrier discharge for the removal of organic pollutant adsorbed on activated carbon

    Qu, G.Z.; Li, G.F. [Dalian Univ. of Technology, Dalian (China). Inst. of Electrostatics and Special Power; Li, J.; Lu, N.; Wu, Y.; Li, D. [Dalian Univ. of Technology, Dalian (China). Inst. of Electrostatics and Special Power; Key Lab of Industrial Ecology and Environmental Engineering, Ministry of Education, Dalian (China)

    2010-07-01

    Advanced oxidation technologies such as photocatalysis, electrochemical degradation, Fenton oxidation, hydrogen peroxide oxidation, and plasma oxidation are increasingly being used to degrade refractory biodegradable organic contaminants. The plasma oxidation method has the advantage of direct in situ production of multiple types of high-reactive chemical species, including molecules and radicals that facilitate the degradation reaction. In addition, plasma oxidation does not produce any secondary pollution. Compared to other plasma technologies, the dielectric barrier discharge (DBD) plasma has been considered as a promising technology for removing toxic compounds because of its stability and its treatability property of biologically recalcitrant compounds in wastewater. However, the energy efficiency of DBD requires improvement for economic reasons. This paper reported on an experimental study that investigated the electrical characteristics of a parallel plate DBD reactor using a high frequency power supply for the removal of pentachlorophenol (PCP) adsorbed on activated carbon (AC). This study examined the effects of AC with different mass on discharge characteristics and compared the voltage and current waveforms, and discharge images of DBD reactors with different dielectric configurations. When the DBD reactor filled with AC, the applied voltage of discharge decreased regardless of the DBD reactor configuration in terms of having a single barrier or two barriers. The discharge characteristics had no significant change with AC mass increasing. The discharge images and current waveforms showed that DBD reactor configuration consisting of two dielectrics is more homogeneous and stable than the one consisting of a single dielectric. Under the same electric field condition, the degradation efficiency of PCP in two barriers reactor is higher than that in single barrier reactor. It was concluded that the findings from this study may be instrumental in treating

  11. Dominant discharge – an outline of theory and a case study from the Raba river

    Wiktoria Czech

    2016-06-01

    Full Text Available Designing hydraulic structures engineers has only theoretical flows, calculated using formulas based on statistics. Knowledge of the dominant discharge could help determine designers who are interested in changes of the morphology of river channels, especially in terms of sediment transport. It was observed that the designing of a stable channel in the river is possible when defining characteristic of flow in the river which is the most frequently present in the river and in the same time it carries the sediment. That is the dominant discharge. It is this movement can represent both the hydraulic system and the geometry of the river cross-sections. The dominant discharge (also called river shaping channel discharge is considered by many authors as a discharge that transports the largest amount of sediment, it takes a long time and has an impact on the formation of the shape of the river bed. Observations of Wolman and Miller showed that low but frequent flows of water might be responsible for new shape of the river channel, erosion of the riverbed, sediment deposition and consequently changes in river morphology. The paper presents Wolman method for dominant discharge use for the Raba River for chosen gauge cross section. Along in the paper we discuss the obtained results and the consequences of using dominant discharge for the practice. In six cross sections on the Raba River, Qdd was calculated values, which range from 31 m3 • s–1 (for the section in Rabka to 395 m3 • s–1 (in Proszówki. These flows occur every two years (for the upper sections of the river, and every four years (for cross-sections located in the lower section of the river.

  12. Study of the excitation mechanisms of the second positive system in the negative glow of a N2-Ar discharge

    Isola, L; Lopez, M; Gomez, B J

    2011-01-01

    In an Ar-N 2 discharge, the high excitation transfer from Ar( 3 P 2,0 ) to N 2 produces an overpopulation of the high rotational levels of the bands of the second positive system (SPS), and so the spectra interpretation is not straightforward. This paper presents a fit function for the SPS bands measured in Ar-N 2 , which allows us to study the excitation process contributions to the N 2 (C) level. The procedure was tested in the negative glow of a pulsed Ar-N 2 discharge at a pressure of 2.5 Torr, for different mixture concentrations. In this discharge, through the fitting, it was possible to calculate the variation of the N 2 (C) densities produced by different excitation processes as well as the variation of Ar metastable density.

  13. Study of emission of a volume nanosecond discharge plasma in xenon, krypton and argon at high pressures

    Baksht, E Kh; Lomaev, Mikhail I; Rybka, D V; Tarasenko, Viktor F

    2006-01-01

    The emission properties of a volume nanosecond discharge plasma produced in xenon, krypton and argon at high pressures in a discharge gap with a cathode having a small radius of curvature are studied. Spectra in the range 120-850 nm and amplitude-time characteristics of xenon emission at different regimes and excitation techniques are recorded and analysed. It is shown that upon excitation of the volume discharge initiated by a beam of avalanche electrons, at least 90% of the energy in the spectral range 120-850 nm is emitted by xenon dimers. For xenon at a pressure of 1.2 atm, ∼45 mJ of the spontaneous emission energy was obtained in the full solid angle in a pulse with the full width at half-maximum ∼130 ns. (laser applications and other topics in quantum electronics)

  14. Studies on some biochemical parameters in viral hepatitis patients

    El-Sherbiny, E.M.

    2002-01-01

    The present investigation deals with studying liver amino transferases (ALT. AST). Cholesterol and triglycerides. As well as testosterone and protection hormones in blood of Egyptian men infected with hepatitis C virus.hepatitis B virus and mixed B and C viruses. These biochemical parameters were evaluated to be used in diagnosis and prognosis of viral hepatitis. Which considered the most important health problem in Egypt and developing countries. Biochemical analysis were performed using spectrophotometric and radioimmunoassay techniques. All data will be subjected to statistical analysis in order to detect the most suitable biochemical analysis that can be used as specific tests for early diagnosis of viral hepatitis and to detect the parameters that show abnormalities among the different groups of infected patients. The data revealed that AST and ALT levels were increased in all patient groups. Concerning the level of triglycerides, it was increased only in the group of mixed viral hepatitis B and C, while cholesterol showed non-significant changes in all viral hepatitis groups. The sex hormone testosterone was decreased in all infected patients while the prolactin level was increased only in case of patients infected with mixed B and C viruses. However, these abnormal values in such sex hormones play a serious role in male sterility

  15. Preparation of electrodeless discharge lamps for emission studies of uranium isotopes at trace level

    Bhowmick, G.K.; Verma, R.; Verma, M.K.; Raman, V.A.; Joshi, A.R.; Deo, M.N.; Gantayet, L.M.; Tiwari, A.K.; Ramakumar, K.L.; Kumar, Navin

    2010-01-01

    A simplified method for preparation of electrodeless discharge lamp for uranium isotopes with specific concerns for 232 U is described. Micro-gram quantities of solid uranium oxides and aqueous solution of uranium nitrate have been used as a starting material for in situ synthesis of uranium tetraiodide. High temperature iodination reaction is carried out in the presence of inert gas neon. By careful design, the preparation time and surface area of quartz reaction tubes have been reduced considerably. The latter decreases the level of contamination which has a direct bearing on the operational lifetime of the lamps. Incorporation of steps to purify the product from an unwanted material improved the stability of the lamps. The procedure provides a safe and convenient way of handling 232 U in particular but can be extended in general to any actinides having radioactivity similar to that of freshly separated 232 U. Characteristic emission of uranium isotopes have been recorded by Fourier Transform Spectrometer to show the satisfactory operation of the lamps as well as their usage for studying emission spectra of the specific isotope.

  16. Coding of obesity in administrative hospital discharge abstract data: accuracy and impact for future research studies.

    Martin, Billie-Jean; Chen, Guanmin; Graham, Michelle; Quan, Hude

    2014-02-13

    Obesity is a pervasive problem and a popular subject of academic assessment. The ability to take advantage of existing data, such as administrative databases, to study obesity is appealing. The objective of our study was to assess the validity of obesity coding in an administrative database and compare the association between obesity and outcomes in an administrative database versus registry. This study was conducted using a coronary catheterization registry and an administrative database (Discharge Abstract Database (DAD)). A Body Mass Index (BMI) ≥30 kg/m2 within the registry defined obesity. In the DAD obesity was defined by diagnosis codes E65-E68 (ICD-10). The sensitivity, specificity, negative predictive value (NPV) and positive predictive value (PPV) of an obesity diagnosis in the DAD was determined using obesity diagnosis in the registry as the referent. The association between obesity and outcomes was assessed. The study population of 17380 subjects was largely male (68.8%) with a mean BMI of 27.0 kg/m2. Obesity prevalence was lower in the DAD than registry (2.4% vs. 20.3%). A diagnosis of obesity in the DAD had a sensitivity 7.75%, specificity 98.98%, NPV 80.84% and PPV 65.94%. Obesity was associated with decreased risk of death or re-hospitalization, though non-significantly within the DAD. Obesity was significantly associated with an increased risk of cardiac procedure in both databases. Overall, obesity was poorly coded in the DAD. However, when coded, it was coded accurately. Administrative databases are not an optimal datasource for obesity prevalence and incidence surveillance but could be used to define obese cohorts for follow-up.

  17. Experimental study on scale removal from special-shaped conduits through underwater electrical discharge

    Cao, Y; Wang, Z Q; Li, G F; Wu, Y; Zhou, J J

    2013-01-01

    Underwater electrical discharge technology is an innovative technique that can be used to enhance the stress intensity of water and improve the load addition. The technique enlarges the section area and compresses the surrounding water using a high-powered shock wave, which is induced by an underwater electrical discharge. This paper investigates the effectiveness of scale removal for special-shaped conduits employing underwater electrical discharge. Experimental results show that the pressure wave generated by underwater electrical discharge is capable of eliminating scale in special-shaped conduits. The data indicates that when the capacitance of the parallel-pulsed capacitors was 4 μF, the high pulsed power voltage was 33 kV and the primary discharge gap was 48 mm, the result of scale removal was remarkable. In laboratory tests, the scale of special equipment was removed to a great extent by this method. Because of its effectiveness and low cost, this method improves the practice and extends the lifetime of such equipment, and thus has potential application and economic value.

  18. Study of Operating Parameters for Accelerated Anode Degradation in SOFCs

    Ploner, Alexandra; Hagen, Anke; Hauch, Anne

    2017-01-01

    Solid oxide fuel cell (SOFC) applications require lifetimes of several years on the system level. A big challenge is to demonstrate such exceptionally long lifetimes in ongoing R&D projects. Accelerated or compressed testing are alternative methods to obtain this. Activities in this area have been...... carried out without arriving at a generally accepted methodology. This is mainly due to the complexity of degradation mechanisms on the single SOFC components as function of operating parameters. In this study, we present a detailed analysis of approx. 180 durability tests regarding degradation of single...... SOFC components as function of operating conditions. Electrochemical impedance data were collected on the fresh and long-term tested SOFCs and used to de-convolute the individual losses of single SOFC cell components – electrolyte, cathode and anode. The main findings include a time-dependent effect...

  19. Struggling for Independence: A Grounded Theory Study on Convalescence of ICU-survivors 12 Months Post ICU Discharge

    Ågård, Anne Sophie; Egerod, Ingrid; Tønnesen, Else Kirstine

    2012-01-01

    Objectives: To explore and explain the challenges, concerns and coping modalities in ICU-survivors living with a partner or spouse during the first 12 months post ICU discharge. Design: Qualitative, longitudinal grounded theory study. Settings: Five ICUs in Denmark, four general, one neurosurgical...

  20. Secondary health conditions in persons with spinal cord injury : A longitudinal study from one to five years post-discharge

    Adriaansen, Jacinthe J. E.; Post, Marcel W. M.; de Groot, Sonja; van Asbeck, Floris W. A.; Stolwijk-Swuste, Janneke M.; Tepper, Marga; Lindeman, Eline

    2013-01-01

    Objective: To assess the occurrence of secondary health conditions and their potential risk factors in persons with spinal cord injury from 1 to 5 years after discharge from initial inpatient rehabilitation. Design: Multicentre longitudinal study. Subjects: A total of 139 wheelchair-dependent

  1. Does Cigarette Smoking Affect Seminal Fluid Parameters? A Comparative Study

    Zakarya Bani Meri

    2013-01-01

    Full Text Available Objective: To study the effect of cigarette smoking on seminal fluid parameters, namely; volume, sperm concentration, and motility, as well as morphology, leukocyte infiltration, among males complaining of infertility.Methods: Between August 2010 and July 2011, seminal fluid analysis was done for 1438 males who are partners of couples who visited the infertility clinic at Prince Rashid Ben Al Hassan Hospital (PRH for infertility. The men who fit the inclusion criteria (n=960 were classified into two groups: group a (non-smokers; n=564 and group B (smokers; n=396, which represents 41.25% of the study group. Seminal fluid was collected using masturbation after 3-5 days of abstinence then analyzed for volume, sperm count, sperm concentration, motility and morphology. In order to analyze whether the number of cigarettes smoked per day has an effect on the spermatogram; the smoking men were divided into two subgroups: the heavy smokers (n=266 and non-heavy smokers (n=130.Results: A total of 960 adult males were enrolled. Their age ranged between 21 and 76 years, 564 were non-smokers with mean age of 36. 45±6.27 (Mean±SD. Three-hundred-and-ninety-six were smokers with a mean age of 34.35±4.25 (Mean±SD. There was a significant effect of smoking on the motility of sperms and the ratios of abnormality (p<0.005. Concentration appeared not to be affected by smoking. Furthermore, the group of heavy smokers were found to have lower sperm concentrations and a higher percentage of abnormal sperms compared to the non-heavy smokers.Conclusion: Cigarette smoking has a deleterious effect on some of the seminal fluid parameters (motility, morphology and leukocyte count which in turn may result in male subfertility.

  2. The study of discharge cleaning in the JFT-2 tokamak with surface observation by AES

    Gomay, Yoshio; Tazima, Teruhiko; Fujisawa, Noboru; Suzuki, Norio; Konoshima, Shigeru

    1976-07-01

    Noticeable correlations were observed between the changes of discharge characteristics, wall conditions and typical mass peaks with discharge cleaning in the JFT-2 tokamak. Atomic composition of the vacuum wall surface observed by AES becomes constant with continuing discharge cleaning in the level except hydrogen and helium: 30-50% C, 20-30% Mo, 15-30% stainless steel elements and 10-15% O. The stable reproducible plasma with Z sub(eff)=4.5 was obtained in this wall condition. The limiter and vacuum wall materials (Mo and 304 stainless steel, respectively), carbon and oxygen were observed depositing on the wall in the thickness of about 300 A at the minimum inner radius of the vacuum chamber and 40 A nearly at the maximum after 2900 cleaning pulses. The mechanism determining the wall condition is also discussed. (auth.)

  3. A study on improvement of discharge characteristic by using a transformer in a capacitively coupled plasma

    Kim, Young-Cheol [Department of Nanoscale Semiconductor Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul 133-791 (Korea, Republic of); Kim, Hyun-Jun; Lee, Hyo-Chang; Chung, Chin-Wook, E-mail: joykang@hanyang.ac.kr [Department of Electrical Engineering, Hanyang University, 222 Wangsimni-ro, Seongdong-gu, Seoul 133-791 (Korea, Republic of)

    2015-12-15

    In a plasma discharge system, the power loss at powered line, matching network, and other transmission line can affect the discharge characteristics such as the power transfer efficiency, voltage and current at powered electrode, and plasma density. In this paper, we propose a method to reduce power loss by using a step down transformer mounted between the matching network and the powered electrode in a capacitively coupled argon plasma. This step down transformer decreases the power loss by reducing the current flowing through the matching network and transmission line. As a result, the power transfer efficiency was increased about 5%–10% by using a step down transformer. However, the plasma density was dramatically increased compared to no transformer. This can be understood by the increase in ohmic heating and the decrease in dc-self bias. By simply mounting a transformer, improvement of discharge efficiency can be achieved in capacitively coupled plasmas.

  4. Intervention among new parents followed up by an interview study exploring their experiences of telemedicine after early postnatal discharge.

    Danbjørg, D B; Wagner, L; Kristensen, B R; Clemensen, J

    2015-06-01

    a move towards earlier postnatal discharge raises the challenge of finding new ways to support families when they are discharged early after childbirth. to explore how postnatal parents experienced the use of telemedicine following early discharge from hospital (i.e. 24 hours after childbirth) by investigating if they consider that their postnatal needs are met, and whether or not they experience a sense of security and parental self-efficacy. intervention followed by a qualitative interview study. The intervention took place on a postnatal ward with approximately 1000 births a year. An app including chat, a knowledgebase and automated messages was trialled between postnatal parents at home and the hospital. Parents had access to the app for seven days after discharge. 42 new mothers were recruited from the postnatal ward in accordance with the inclusion criteria (i.e. discharged within 24 hours of childbirth). Both parents were invited for interview. 42 sets of parents participated in the trial, and 28 sets agreed to be interviewed. Interviews (n=28) were conducted with 27 mothers and 11 fathers. Parents were interviewed together in 10 cases, 17 mothers were interviewed alone, and one father was interviewed alone. The data analysis was inspired by systematic text condensation based on Giorgi׳s descriptive phenomenological method. parents were confident in use of the app, and did not experience any barriers in contacting the nurses via asynchronous communication. Parents received timely information and guidance by communicating online, and felt that their follow-up support needs were met. parents viewed the app as a lifeline, and saw it as a means of informing and guiding them following early discharge from hospital after childbirth. As such, this app shows potential for enhancing self-efficacy and postnatal sense of security. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Ileostomy - discharge

    ... dried fruits (such as raisins), mushrooms, chunky relishes, coconut, and some Chinese vegetables. Tips for when no ... ask your doctor Living with your ileostomy Low-fiber diet Small bowel resection - discharge Total colectomy or ...

  6. Post-discharge body weight and neurodevelopmental outcomes among very low birth weight infants in Taiwan: A nationwide cohort study

    Hsu, Chung-Ting; Chen, Chao-Huei; Wang, Teh-Ming; Hsu, Ya-Chi

    2018-01-01

    Background Premature infants are at high risk for developmental delay and cognitive dysfunction. Besides medical conditions, growth restriction is regarded as an important risk factor for cognitive and neurodevelopmental dysfunction throughout childhood and adolescence and even into adulthood. In this study, we analyzed the relationship between post-discharge body weight and psychomotor development using a nationwide dataset. Materials and methods This was a nationwide cohort study conducted in Taiwan. Total of 1791 premature infants born between 2007 and 2011 with a birth weight of less than 1500 g were enrolled into this multi-center study. The data were obtained from the Taiwan Premature Infant Developmental Collaborative Study Group. The growth and neurodevelopmental evaluations were performed at corrected ages of 6, 12 and 24 months. Post-discharge failure to thrive was defined as a body weight below the 3rd percentile of the standard growth curve for Taiwanese children by the corrected age. Results The prevalence of failure to thrive was 15.8%, 16.9%, and 12.0% at corrected ages of 6, 12, and 24 months, respectively. At corrected ages of 24 months, 12.9% had low Mental Developmental Index (MDI) scores (MDIneurodevelopmental impairment. Post-discharge failure to thrive was significantly associated with poor neurodevelopmental outcomes. After controlling for potential confounding factors (small for gestational age, extra-uterine growth retardation at discharge, cerebral palsy, gender, mild intraventricular hemorrhage, persistent pulmonary hypertension of newborn, respiratory distress syndrome, chronic lung disease, hemodynamic significant patent ductus arteriosus, necrotizing enterocolitis, surfactant use and indomethacin use), post-discharge failure to thrive remained a risk factor. Conclusion This observational study observed the association between lower body weight at corrected age of 6, 12, and 24 months and poor neurodevelopmental outcomes among VLBW

  7. Damping parameter study of a perforated plate with bias flow

    Mazdeh, Alireza

    role of LES for research studies concerned with damping properties of liners is limited to validation of other empirical or theoretical approaches. This research has shown that LES can go beyond that and can be used for performing parametric studies to characterize the sensitivity of acoustic properties of multi--perforated liners to the changes in the geometry and flow conditions and be used as a tool to design acoustic liners. The conducted research provides an insightful understanding about the contribution of different flow and geometry parameters such as perforated plate thickness, aperture radius, porosity factors and bias flow velocity. While the study agrees with previous observations obtained by analytical or experimental methods, it also quantifies the impact from these parameters on the acoustic impedance of perforated plate, a key parameter to determine the acoustic performance of any system. The conducted study has also explored the limitations and capabilities of commercial tool when are applied for performing simulation studies on damping properties of liners. The overall agreement between LES results and previous studies proves that commercial tools can be effectively used for these applications under certain conditions.

  8. Study of nickel hydrogen battery discharge performance after charge and stand at warm temperature

    Donley, S.W.; Verrier, D.C.

    1992-01-01

    Spacecraft batteries are normally installed in the discharged condition. It may be necessary that they be charged and trickle-charged prior to launch in an environment different from that in which they are intended to operate. The purpose of the testing described in this paper was to determine the battery capacity achieved after treatment at prelaunch conditions as a function of charge rate, charge temperature, trickle charge temperature, and time. In this testing the discharge in every case was performed under simulated space thermal conditions

  9. Study of a pulsed discharge in nitrogen: the N2 laser

    Spyrou, N

    1979-01-01

    The characteristics of the pulsed nitrogen discharge and the power supply circuit of an N2 laser operating in the UV are investigated. Following a review of the characteristics of molecular lasers in general and the N2 laser in particular, a theoretical model based on a simultaneous description of the electric circuit and the discharge is developed to explain such laser characteristics as current evolution and electron density and temperature and to allow the calculation of laser energy levels. The theoretical model is found to be in agreement with experimental results, and optimal conditions for the operation of the experimental laser are obtained.

  10. Effect of machining parameters on surface integrity of silicon carbide ceramic using end electric discharge milling and mechanical grinding hybrid machining

    Ji, Renjie; Liu, Yonghong; Zhang, Yanzhen; Cai, Baoping; Li, Xiaopeng; Zheng, Chao

    2013-01-01

    A novel hybrid process that integrates end electric discharge (ED) milling and mechanical grinding is proposed. The process is able to effectively machine a large surface area on SiC ceramic with good surface quality and fine working environmental practice. The polarity, pulse on-time, and peak current are varied to explore their effects on the surface integrity, such as surface morphology, surface roughness, micro-cracks, and composition on the machined surface. The results show that positive tool polarity, short pulse on-time, and low peak current cause a fine surface finish. During the hybrid machining of SiC ceramic, the material is mainly removed by end ED milling at rough machining mode, whereas it is mainly removed by mechanical grinding at finish machining mode. Moreover, the material from the tool can transfer to the workpiece, and a combination reaction takes place during machining.

  11. Glow discharge mass spectrometry study of chemical impurities diffusion in zirconium oxide layers

    Actis-Dato, L.O.

    2000-02-01

    In the Pressurised Water Reactors (PWR) the primary cooling system is water at 350 deg C and 16 Mpa. In these extreme conditions the corrosion of the out-of-pile components of the reactor and in particular of the Zircaloy cladding containing the nuclear fuel pellets is accelerated. The formation of a growing oxide layer is observed on the elements of the nuclear reactor core. When the thickness of the oxide layer reaches a critical value, problems like structural malfunction and material failure can occur. At this stage the danger of the release of radioactivity in the coolant becomes effective. In this work a glow discharge mass spectrometer is used to study the diffusion of impurities like lithium, zinc and boron in oxide layers growing on Zircaloy samples. After a brief description of the different technique used the preparation and analysis of Zircaloy samples on which oxide layers of different thickness have been produced will be described. The analysis of these samples will allow the determination and evaluation the depth profiles of the impurities absorbed by the oxide. The analysis of the shape of the crater produced during the mass spectrometric analysis will give additional informations on the quality of the results obtained. The technique developed will finally be applied to the study of samples produced during reactor operation under real irradiation conditions. The results obtained show a lithium intake in the oxide layer and confirm the beneficial effect on the corrosion produced by boron. The influence of zinc on the corrosion behaviour of Zircaloy has not been established. The technique developed has also shown interesting capabilities concerning the analysis of irradiated samples. (author)

  12. Large Dam Effects on Flow Regime and Hydraulic Parameters of river (Case study: Karkheh River, Downstream of Reservoir Dam

    Farhang Azarang

    2017-06-01

    Full Text Available Introduction: The critical role of the rivers in supplying water for various needs of life has led to engineering identification of the hydraulic regime and flow condition of the rivers. Hydraulic structures such dams have inevitable effects on their downstream that should be well investigated. The reservoir dams are the most important hydraulic structures which are the cause of great changes in river flow conditions. Materials and Methods: In this research, an accurate assessment was performed to study the flow regime of Karkheh river at downstream of Karkheh Reservoir Dam as the largest dam in Middle East. Karkheh River is the third waterful river of Iran after Karun and Dez and the third longest river after the Karun and Sefidrud. The Karkheh Dam is a large reservoir dam built in Iran on the Karkheh River in 2000. The Karkheh Reservoir Dam is on the Karkheh River in the Northwestern Khouzestan Province, the closest city being Andimeshk to the east. The part of Karkheh River, which was studied in this research is located at downstream of Karkheh Reservoir Dam. This interval is approximately 94 km, which is located between PayePol and Abdolkhan hydrometric stations. In this research, 138 cross sections were used along Karkheh River. Distance of cross sections from each other was 680m in average. The efficient model of HEC-RAS has been utilized to simulate the Karkheh flow conditions before and after the reservoir dam construction using of hydrometric stations data included annually and monthly mean discharges, instantaneous maximum discharges, water surface profiles and etc. Three defined discharges had been chosen to simulate the Karkheh River flow; maximum defined discharge, mean defined discharge and minimum defined discharge. For each of these discharges values, HEC-RAS model was implemented as a steady flow of the Karkheh River at river reach of study. Water surface profiles of flow, hydraulic parameters and other results of flow regime in

  13. THE STUDY OF THE MAIN PARAMETERS QUALITY OF BUFFALO MILK

    AURELIA PECE

    2010-02-01

    Full Text Available Researches were conducted on a biologic material, a buffalo livestock, in different lactating stages and their physico-chemical parameters were determined: fat, protein, lactose, unfat dry substance, density, pH, temperature. Regarding the variation of these components, researches conducted emphasized differences determined by those conditions specific to reference seasons. Individual analysis on the buffalo livestock in the study, emphasized significant differences: fat 8.59-9.36%, protein 5.16-5.31% respective of lactation. Microbiologic determinations mainly envisioned: the number of somatic cells (NSC, number of total germs (NTG Positive Coagulanzo Stafilococii, Listeria, Salmonella, determinations which lay at the basis of the assessment of buffalo milk quality. The positive Coagulanzo stafilococus was absent, excepting sample number 15 (2 germs/ml and sample number 22 (4 germs/ml; Salmonella was absent. Regarding the total number of germs: values between 1.0-1.8 germs/ml were obtained. The detection of this microbiologic parameter in the composition of buffalo milk provides information regarding the hygienic conditions of their production and handling. Correlations between the number of somatic cells, milk production and composition are employed in dairy buffalo farms, in order to assess losses caused by mastitis and the implementing of certain measures for the control of these diseases. On the other hand, correlations between the number of somatic cells and milk composition prove useful in establishing milk processing behaviour, as the practice of setting milk-raw matter prices according to the number of somatic cells in the milk is becoming increasingly more frequent in developed countries.

  14. studies on the correlation of some aggregate parameters in the ...

    BARTH EKWUEME

    simulations for problem solving and forecasting environmental conditions .... METHODS. Parameters: The water quality parameters examined were, Turbidity, Total Dissolved Solids (TDS),. Chemical Oxygen Demand (COD), 5-day Biochemical. Oxygen Demand ..... Vogel's Textbook of Quantitative. Chemical Analysis 6th ed ...

  15. Systematic parameter study of dynamo bifurcations in geodynamo simulations

    Petitdemange, Ludovic

    2018-04-01

    We investigate the nature of the dynamo bifurcation in a configuration applicable to the Earth's liquid outer core, i.e. in a rotating spherical shell with thermally driven motions with no-slip boundaries. Unlike in previous studies on dynamo bifurcations, the control parameters have been varied significantly in order to deduce general tendencies. Numerical studies on the stability domain of dipolar magnetic fields found a dichotomy between non-reversing dipole-dominated dynamos and the reversing non-dipole-dominated multipolar solutions. We show that, by considering weak initial fields, the above transition disappears and is replaced by a region of bistability for which dipolar and multipolar dynamos coexist. Such a result was also observed in models with free-slip boundaries in which the geostrophic zonal flow can develop and participate to the dynamo mechanism for non-dipolar fields. We show that a similar process develops in no-slip models when viscous effects are reduced sufficiently. The following three regimes are distinguished: (i) Close to the onset of convection (Rac) with only the most critical convective mode (wave number) being present, dynamos set in supercritically in the Ekman number regime explored here and are dipole-dominated. Larger critical magnetic Reynolds numbers indicate that they are particularly inefficient. (ii) in the range 3 10) , the relative importance of zonal flows increases with Ra in non-magnetic models. The field topology depends on the magnitude of the initial magnetic field. The dipolar branch has a subcritical behavior whereas the multipolar branch has a supercritical behavior. By approaching more realistic parameters, the extension of this bistable regime increases. A hysteretic behavior questions the common interpretation for geomagnetic reversals. Far above the dynamo threshold (by increasing the magnetic Prandtl number), Lorentz forces contribute to the first order force balance, as predicted for planetary dynamos. When

  16. Bioaccumulation Study of Produced Water Discharges from Southeastern Brazilian Offshore Petroleum Industry Using Feral Fishes.

    Lourenço, Rafael André; Francioni, Eleine; da Silva, Antonio Henrique M F T; Magalhães, Caio Augusto; Gallotta, Fabiana Dias Costa; de Oliveira, Fabio Francisco; de Souza, João Maximino; de Araújo, Leandro Franco Macena; de Araújo, Liliane Pequeno; de Araújo Júnior, Marcus Antonio G; de Fátima Guadalupe Meniconi, Maria; de Souza Bindes Gomes Lopes, Monica Aparecida Ferreira

    2018-04-01

    The main effluent of oil and gas production is the discharge of produced water (PW). Despite the potential environmental impact, the structure of oil and gas platforms can act as artificial reefs. Two species of fish, Caranx crysos and Tylosurus acus, were captured under two discharging platforms at Campos Basin, P19 and P40. A nondischarging platform, P25, was taken as reference. The highest median concentration of PAH in muscle tissue was observed for C. Crysos at P40 (219.38 ng g -1 ) followed by P19 (68.26 ng g -1 ). For T. acus, the highest median concentrations were 40.07 and 42.21 ng g -1 from P19 and P40 respectively. P25 presented the smallest recorded concentrations. The results of PAH in the muscle tissue of C. crysos enabled to distinguish the platforms with PW discharge from the platform without discharge. Trace elements concentrations reflected the background levels and were not influenced by the PW release.

  17. Plasma Discharge Initiation of Explosives in Rock Blasting Application: A Case Study

    Chae, Jae-Ou; Jeong, Young-Jun; Shmelev, V M; Denicaev, A A; Poutchkov, V M; Ravi, V

    2006-01-01

    A plasma discharge initiation system for the explosive volumetric combustion charge was designed, investigated and developed for practical application. Laboratory scale experiments were carried out before conducting the large scale field tests. The resultant explosions gave rise to less noise, insignificant seismic vibrations and good specific explosive consumption for rock blasting. Importantly, the technique was found to be safe and environmentally friendly

  18. 75 FR 10477 - Draft Report to Congress: Study of Discharges Incidental to Normal Operation of Commercial...

    2010-03-08

    ... dissolved metals; volatile and semivolatile organic compounds (VOCs and SVOCs); nonylphenols ethoxylates... evaluate the impacts of: (1) Any discharge of effluent from properly functioning marine engines; (2) Any...-disrupting compounds); and pathogen indicators (i.e., E. coli, enterococci, fecal coliforms). EPA found that...

  19. Experimental study on hard X-rays emitted from metre-scale negative discharges in air

    P.O. Kochkin (Pavlo); A. van Deursen (Arie); U. M. Ebert (Ute)

    2015-01-01

    htmlabstractWe investigate the development of metre long negative discharges and focus on their x-ray emissions. We describe appearance, timing and spatial distribution of the x-rays. They appear in bursts of nanosecond duration mostly in the cathode area. The spectrum can be characterized by an

  20. Current discharge management of acute coronary syndromes: Data from the Rijnmond Collective Cardiology Research (CCR) study

    T. Yetgin; M.M.J.M. van der Linden (Mark); A.G. de Vries (A.); P.C. Smits (Pieter); R. van Mechelen; S-C. Yap (Sing-Chien); H. Boersma (Eric); F. Zijlstra (Felix); R.J.M. van Geuns (Robert Jan)

    2014-01-01

    textabstractBackground Medical discharge management of acute coronary syndromes (ACS) remains suboptimal outside randomised trials and constitutes an essential quality benchmark for ACS. We sought to evaluate the rates of key guideline-recommended pharmacological agents after ACS and characteristics

  1. Study the dispersion the possible thermal discharges to Juragua nuclear power plant. Preliminary results

    Munnoz Caravaca, A.; Artega Rodriguez, H.; Diaz Asencio, M.; Cartas Aguila, H.

    1998-01-01

    The present work has as objective to present the results the evaluation to the surface area impact to the waters cooling discharges the Juragua nuclear power plant, by means of hydrodynamic models that described the possible distribution the same ones in the boundary marine means to the location

  2. A study on the electrical characteristics of corona discharges for flue gas treatment

    Jung, Suk Won

    2000-02-01

    A wire- cylinder reactor and wire- plate reactor were designed and constructed for generating the corona discharges to be applied to the dissociation of NOx and SOx in the flue gases of combustion engines and power plants. Experiments for the characterization of the corona discharges in air were carried out. To obtain the pulsed voltage shape, a rotary spark gap switch was formed with a DC motor. A discharge circuit was constructed with a resistor (50kΩ ), DC high voltage power supply, a rotary spark gap switch. Two electric probes and voltage probe were installed in order to measure the total current, displacement current, conduction current and applied voltage. The charges, power, and energy in the two reactors were calculated from the measured voltage and current. Also, to find the frequency dependence of the corona discharge, the high frequency (20kHz) and high voltage power supply was used in the wire- cylinder reactor. The each obtained and calculated value from the probes in both reactor cases (high frequency, low frequency ) were compared each other

  3. Psychosocial risk factors for hospital readmission in COPD patients on early discharge services: a cohort study

    Todd Christopher J

    2011-11-01

    Full Text Available Abstract Background Hospital readmission for acute exacerbation of COPD (AECOPD occurs in up to 30% of patients, leading to excess morbidity and poor survival. Physiological risk factors predict readmission, but the impact of modifiable psychosocial risk factors remains uncertain. We aimed to evaluate whether psychosocial risk factors independently predict readmission for AECOPD in patients referred to early discharge services (EDS. Methods This prospective cohort study included 79 patients with AECOPD cared for by nurse led EDS in the UK, and followed up for 12 months. Data on lung function, medical comorbidities, previous hospital admissions, medications, and sociodemographics were collected at baseline; St George's Respiratory Questionnaire (SGRQ, Hospital Anxiety and Depression Scale (HADS, and social support were measured at baseline, 3 and 12-months. Exploratory multivariate models were fitted to identify psychosocial factors associated with readmission adjusted for known confounders. Results 26 patients were readmitted within 90 days and 60 patients were readmitted at least once during follow-up. Depression at baseline predicted readmission adjusted for sociodemographics and forced expiratory volume in 1 second (odds ratio 1.30, 95% CI 1.06 to 1.60, p = 0.013. Perceived social support was not significantly associated with risk of readmission. Home ownership was associated with the total number of readmissions (B = 0.46, 95% CI -0.86 to -0.06, p = 0.024. Compared with those not readmitted, readmitted patients had worse SGRQ and HADS scores at 12 months. Conclusion Depressive symptoms and socioeconomic status, but not perceived social support, predict risk of readmission and readmission frequency for AECOPD in patients cared for by nurse-led EDS. Future work on reducing demand for unscheduled hospital admissions could include the design and evaluation of interventions aimed at optimising the psychosocial care of AECOPD patients managed at

  4. Study of Parameters that Determine Railway Line Capacity

    Josip Kukec

    2005-07-01

    Full Text Available In this work the study focuses on:- determining the elements required to determine the locationfor the installation of the main signals,- calculated block lengths, and- calculations of optimal head ways, that have not been studiedin detail although they deserve special attention due totheir impact.Generally speaking, the signals are installed in compliancewith the local circumstances, i. e. according to the technicaland technological characteristics and conditions determinedby the traffic places of work they protect.The distribution and length of the blocks depend on: therailway line and its exploitation characteristics, structure andtype of trains that run on the railway line, traffic organisationand signalisation system, as well as technical and exploitationcharacte1istics of the traction vehicles and the rolling stock.What has to be considered is that the minimum section lengthcannot be shorter than the length of the braking distance, i. e.the length of the longest train which runs on the respective railwayline.The study of these parameters is supplemented by the calculationof the reduction in throughput capacity depending on thelack of uniformity in the operation of trains, which, in order tomaintain the design quality of the transportation se1vice, and inthe activities of establishing and implementing the business policyshouldn't be left out nor bypassed.

  5. A study on the impulse wave discharged from the exit of a right-angle pipe bend

    Lee, D. H.; Hur, S. C.; Kweon, Y. H.; Kim, H. D.

    2001-01-01

    The current study addresses experimental and computational work of impulse wave discharged from the exit of two kinds of right-angle pipe bends, which are attached to the open end of a simple shock tube. The weak normal shock wave with its magnitude of Mach number from 1.02 to 1.20 is employed to obtain the impulse wave propagating outside the exit of the pipe bends. A Schlieren optical system visualizes the impulse wave discharged from the exit of the pipe bends at an instant. The experimental data of the magnitude of the impulse wave and its propagating directivity are analyzed to characterize the impulse waves discharged from the exit of the pipe bends and compared with those discharged from a straight pipe. Computational results well predict the experimented dynamic behaviors of the impulse wave. The results obtained show that a right-angle miter bend considerably reduces the magnitude of the impulse wave and its directivity toward to the pipe axis, compared with the straight pipe and right-angle smooth bend. It is believed that the right-angle miter bend pipe can play a role of a passive control against the impulse wave

  6. Numerical study of active particles creation and evolution in a nitrogen point-to-plane afterglow discharge at low pressure

    Potamianou, S; Spyrou, N; Held, B; Loiseau, J-F

    2006-01-01

    The last part of a numerical study of low-pressure nitrogen cold plasma created by a pulsed discharge in a point-to-plane geometry at 4 Torr is presented. The present work deals with the discharge and plasma behaviour during the falling part of a rectangular shaped applied voltage pulse and completes our investigation of the discharge under the stress of this voltage shape. The relative model is based on fluid description of the cold plasma, on Poisson's equation for the electric field and on balance equations for the excited population taking into account only the most important generation and decay mechanisms of the radiative B 3 Π g , C 3 Π u and the metastables A 3 Σ μ + states of nitrogen, according to the conclusions of our recent work (Potamianou et al 2003 Eur. Phys. J. Appl. Phys. 22 179-88). Results for space and time evolution of the charged particles densities, electric field, potential and electron current density are reported. According to these results, a non-neutral channel is formed that evolves slowly and ends in the formation of a double layer. Excited particle distributions are presented and the influence of the electron current density discussed. It seems that, in this kind of discharge, creation of active particles is not only due to electron current density but also physicochemical mechanisms. The obtained results will help to determine optimal conditions for polymer surface treatment

  7. Simulation Study on the Controllable Dielectrophoresis Parameters of Graphene

    Ji, Jian-Long; Liu, Ya-Li; Ge, Yang; Xie, Sheng-Dong; Zhang, Xi; Sang, Sheng-Bo; Jian, Ao-Qun; Duan, Qian-Qian; Zhang, Qiang; Zhang, Wen-Dong

    2017-03-01

    The method of using dielectrophoresis (DEP) to assemble graphene between micro-electrodes has been proven to be simple and efficient. We present an optimization method for the kinetic formula of graphene DEP, and discuss the simulation of the graphene assembly process based on the finite element method. The simulated results illustrate that the accelerated motion of graphene is in agreement with the distribution of the electric field squared gradient. We also conduct research on the controllable parameters of the DEP assembly such as the alternating current (AC) frequency, the shape of micro-electrodes, and the ratio of the gap between electrodes to the characteristic/geometric length of graphene (λ). The simulations based on the Clausius-Mossotti factor reveal that both graphene velocity and direction are influenced by the AC frequency. When graphene is close to the electrodes, the shape of micro-electrodes will exert great influence on the velocity of graphene. Also, λ has a great influence on the velocity of graphene. Generally, the velocity of graphene would be greater when λ is in the range of 0.4-0.6. The study is of a theoretical guiding significance in improving the precision and efficiency of the graphene DEP assembly. Supported by the Basic Research Project of Shanxi Province under Grant No 2015021092, the National Natural Science Foundation of China under Grant Nos 61471255, 61474079, 61501316, 51505324 and 51622507, and the National High-Technology Research and Development Program of China under Grant No 2015AA042601.

  8. Future Circular Collider Study FCC-he Baseline Parameters

    Bruning, Oliver; Klein, Max; Pellegrini, Dario; Schulte, Daniel; Zimmermann, Frank

    2017-01-01

    Initial considerations are presented on the FCC-he, the electron-hadron collider con guration within the Future Circular Collider study. This note considers arguments for the choice of the electron beam energy based on physics, ep scattering kinematics and cost. The default con guration for the electron accelerator, as for the LHeC, is chosen to be a multi-turn energy recovery linac external to the proton beam tunnel. The main accelerator parameters of the FCC-he are discussed, assuming the concurrent operation of ep with the 100TeV cms energy pp collider. These are compared with the LHeC design concept, for increased performance as for a Higgs facility using the HL-LHC, and also the high energy HE-LHC ep collider configuration. Initial estimates are also provided for the luminosity performance of electron-ion colliders for the 60 GeV electron ERL when combined with the LHC, the HE-LHC and the FCC ion beams.

  9. In-situ, time-lapse study of extracellular polymeric substance discharge in Streptococcus mutans biofilm.

    Liu, Bernard Haochih; Yu, Li-Chieh

    2017-02-01

    Streptococcus mutans is one of the main pathogens that cause tooth decay. By metabolizing carbohydrates, S. mutans emits extracellular polymeric substance (EPS) that adheres to the tooth surface and forms layers of biofilm. Periodontal disease occurs due to the low pH environment created by S. mutans biofilm, and such an acidic environment gradually erodes tooth enamel. Since the existence of EPS is essential in the formation of biofilm, the in-situ investigation of its generation and distribution in real time is the key to the control and suppression of S. mutans biofilm. Prior studies of the biofilm formation process by fluorescence microscope, scanning electron microscope, or spectroscope have roughly divided the mechanism into three stages: (1) initial attachment; (2) microcolonies; and (3) maturation. However, these analytical methods are incapable to observe real-time changes in different locations of the extracellular matrix, and to analyze mechanical properties for single bacteria in micro and nanoscale. Since atomic force microscopy (AFM) operates by precise control of tip-sample interaction forces in liquid and in air, living microorganisms can be analyzed under near-physiological conditions. Thus, analytical techniques based on AFM constitute powerful tools for the study of biological samples, both qualitatively and quantitatively. In this study, we used AFM to quantitatively track the changes of multiple nanomechanical properties of S. mutans, including dissipation energy, adhesion force, deformation, and elastic modulus at different metabolic stages. The data revealed that the bacterial extracellular matrix has a gradient distribution in stickiness, in which different stickiness indicates the variation of EPS compositions, freshness, and metabolic stages. In-situ, time-lapse AFM images showed the local generation and distribution of EPS at different times, in which the highest adhesion distributed along sides of the S. mutans cells. Through time

  10. Parameter studies of sediments in the Storegga Slide region

    Yang, S. L.; Kvalstad, T.; Solheim, A.; Forsberg, C. F.

    2006-09-01

    Based on classification tests, oedometer tests, fall-cone tests and triaxial tests, physical and mechanical properties of sediments in the Storegga Slide region were analysed to assess parameter interrelationships. The data show good relationships between a number of physical and mechanical parameters. Goodness of fit between compression index and various physical parameters can be improved by multiple regression analysis. The interclay void ratio and liquidity index correlate well with the undrained shear strength of clay. Sediments with higher water content, liquid limit, activity, interclay void ratio, plasticity index and liquidity index showed higher compression index and/or lower undrained shear strength. Some relationships between parameters were tested by using data from two other sites south of the Storegga Slide. A better understanding of properties of sediments in regions such as that of the Storegga Slide can be obtained through this approach.

  11. Hospital Nurses' and Physicians' Use of Information Sources during their Production of Discharge Summaries: A Cross-Sectional Study

    Hellesø, Ragnhild; Sogstad, Maren Kristine Raknes

    2014-01-01

    Hospital nurses' and physicians' production and exchange of accurate information between levels of care are crucial for ensuring safe and seamless care for patients in transition. We report on a study in which we explored hospital providers' use of information sources when they prepared discharge information for colleges in the community health-care sector. In this cross-sectional study, 510 nurses and 236 physicians responded through a questionnaire. Our findings show that nurses and physici...

  12. Assessment of the interactions between economic growth and industrial wastewater discharges using co-integration analysis: a case study for China's Hunan Province.

    Xiao, Qiang; Gao, Yang; Hu, Dan; Tan, Hong; Wang, Tianxiang

    2011-07-01

    We have investigated the interactions between economic growth and industrial wastewater discharge from 1978 to 2007 in China's Hunan Province using co-integration theory and an error-correction model. Two main economic growth indicators and four representative industrial wastewater pollutants were selected to demonstrate the interaction mechanism. We found a long-term equilibrium relationship between economic growth and the discharge of industrial pollutants in wastewater between 1978 and 2007 in Hunan Province. The error-correction mechanism prevented the variable expansion for long-term relationship at quantity and scale, and the size of the error-correction parameters reflected short-term adjustments that deviate from the long-term equilibrium. When economic growth changes within a short term, the discharge of pollutants will constrain growth because the values of the parameters in the short-term equation are smaller than those in the long-term co-integrated regression equation, indicating that a remarkable long-term influence of economic growth on the discharge of industrial wastewater pollutants and that increasing pollutant discharge constrained economic growth. Economic growth is the main driving factor that affects the discharge of industrial wastewater pollutants in Hunan Province. On the other hand, the discharge constrains economic growth by producing external pressure on growth, although this feedback mechanism has a lag effect. Economic growth plays an important role in explaining the predicted decomposition of the variance in the discharge of industrial wastewater pollutants, but this discharge contributes less to predictions of the variations in economic growth.

  13. Better off in the community? A 5-year follow up study of long-term psychiatric patients discharged into the community.

    McInerney, Shane J

    2010-04-01

    The quality of life of long-term psychiatric inpatients relocated to the community was investigated in this study. The aim was to investigate what changes, if any occurred, on standardised quality of life related instruments between discharge from hospital and at 1 year after discharge into the community. We were also interested to see if these changes continued 5 years after discharge into the community.

  14. Divertor target profiles and recycling studies in TCV single null lower standard discharges

    Pitts, R.A.; Nieswand, C.; Weisen, H.

    1996-05-01

    A 'standard', single null lower diverted discharge has been developed to enable continuous monitoring of the first wall conditions and to characterise the effectiveness and influence of wall conditioning in the TCV tokamak. Measurements over a period encompassing nearly 2000 ohmic discharges of varying configuration and input power show the global confinement time and main plasma impurity concentrations to be good general indicators of the first wall condition, whilst divertor target profiles demonstrate strikingly the short term beneficial effects of He glow. Good agreement, consistent with a reduction in recycling at the plates is found between the predictions of the fluid code UEDGE and the observed outer divertor profiles of T e and n e before and after He glow. (author) 5 figs., 7 refs

  15. Experimental Studies of Anode Sheath Phenomena in a Hall Thruster Discharge

    Dorf, L.; Raitses, Y.; Fisch, N.J.

    2004-01-01

    Both electron-repelling and electron-attracting anode sheaths in a Hall thruster were characterized by measuring the plasma potential with biased and emissive probes [L. Dorf, Y. Raitses, V. Semenov, and N.J. Fisch, Appl. Phys. Let. 84 (2004) 1070]. In the present work, two-dimensional structures of the plasma potential, electron temperature, and plasma density in the near-anode region of a Hall thruster with clean and dielectrically coated anodes are identified. Possible mechanisms of anode sheath formation in a Hall thruster are analyzed. The path for current closure to the anode appears to be the determining factor in the anode sheath formation process. The main conclusion of this work is that the anode sheath formation in Hall thrusters differs essentially from that in the other gas discharge devices, like a glow discharge or a hollow anode, because the Hall thruster utilizes long electron residence times to ionize rather than high neutral pressures

  16. Radioisotope studies on the paradox in dispersion and agglomeration of sewage greases discharged from ocean outfalls

    Davison, A.; Easy, J.F.; Seatonberry, B.W.

    1981-04-01

    Experiments have been undertaken in the ocean off Sydney, Australia to monitor the movement and the dispersion of sewage solids. These solids were labelled with a radioisotope, gold-198 prior to ocean discharge. The labelled material was followed at sea using submersible scintillation detectors. Lateral and vertical dispersion coefficients were determined. The experiments showed that under some conditions the labelled sewage grease dispersed and under others the grease agglomerated. This variation is explained in terms of non-conservative processes

  17. Interprofessional Health Team Communication About Hospital Discharge: An Implementation Science Evaluation Study.

    Bahr, Sarah J; Siclovan, Danielle M; Opper, Kristi; Beiler, Joseph; Bobay, Kathleen L; Weiss, Marianne E

    The Consolidated Framework for Implementation Research guided formative evaluation of the implementation of a redesigned interprofessional team rounding process. The purpose of the redesigned process was to improve health team communication about hospital discharge. Themes emerging from interviews of patients, nurses, and providers revealed the inherent value and positive characteristics of the new process, but also workflow, team hierarchy, and process challenges to successful implementation. The evaluation identified actionable recommendations for modifying the implementation process.

  18. Study of ultrasound-assisted radio-frequency plasma discharges in n-dodecane

    Camerotto, Elisabeth; De Schepper, Peter; Nikiforov, Anton Y.; Brems, Steven; Shamiryan, Denis; Boullart, Werner; Leys, Christophe; De Gendt, Stefan

    2012-10-01

    This paper investigates the generation of a stable plasma phase in a liquid hydrocarbon (n-dodecane) by means of ultrasound (US) and radio-frequency (RF) or electromagnetic radiation. It is demonstrated for the first time that ultrasonic aided RF plasma discharges can be generated in a liquid. Plasma discharges are obtained for different gas mixtures at a pressure of 12 kPa and at low ignition powers (100 W for RF and 2.4 W cm-2 for US). Direct carbon deposition from the liquid precursor on Cu, Ni, SiO2 and Si substrates has been obtained and no apparent compositional or structural difference among the substrate materials was observed. Characterization of the deposited solid phase revealed an amorphous structure. In addition, structural changes in the liquid precursor after plasma treatment have been analysed. Optical emission spectroscopy (OES) allowed the estimation of several plasma characteristic temperatures. The plasma excitation temperature was estimated to be about 2.3-2.4 eV. The rotational and vibrational temperatures of the discharge in n-dodecane with Ar as a feed gas were 1400 K and 6500 K, respectively. In Ar/O2 plasma, an increased rotational (1630 K) and vibrational temperature (7200 K) were obtained.

  19. Interaction of Plasma Discharges with a Flame: Experimental and Numerical Study

    Vincent-Randonnier, Axel; Teixeira, David

    2010-01-01

    This paper presents experimental results and numerical simulations of methane/air non-premixed flame under plasma assistance. Without plasma assistance, the flame blows off at a 28-30 m·s -1 bulk velocity (power around 3 kW). When the discharge is on, the flame can be maintained up to a bulk velocity of 53 m·s -1 (power around 6 kW), corresponding to +90% gain in power with only a few watt of plasma power. The plasma discharges present short duration current pulses (between 100 ns and 200 ns) and occur non-monotonically (delay between two pulses from 6x10 -5 s to 0.1 s). The probability density function of this occurrence is significantly influenced by the mass flow rate or the absence of flame, revealing the strong coupling of the plasma with hydrodynamic and combustion. For the numerical section of this work, we simulated the flame using a Computational Fluid Dynamics code based on Direct Numerical Simulation (direct solving of Navier-Stokes equations), and investigated the thermal and/or chemical effects of discharges on the flame stability.

  20. Nurses' experience of using an application to support new parents after early discharge: an intervention study.

    Boe Danbjørg, Dorthe; Wagner, Lis; Rønde Kristensen, Bjarne; Clemensen, Jane

    2015-01-01

    Background. A development towards earlier postnatal discharge presents a challenge to find new ways to provide information and support to families. A possibility is the use of telemedicine. Objective. To explore how using an app in nursing practice affects the nurses' ability to offer support and information to postnatal mothers who are discharged early and their families. Design. Participatory design. An app with a chat, a knowledgebase, and automated messages was tried out between hospital and parents at home. Settings. The intervention took place on a postnatal ward with approximately 1,000 births a year. Participants. At the onset of the intervention, 17 nurses, all women, were working on the ward. At the end of the intervention, 16 nurses were employed, all women. Methods. Participant observation and two focus group interviews. The data analysis was inspired by systematic text condensation. Results. The nurses on the postnatal ward consider that the use of the app gives families easier access to timely information and support. Conclusions. The app gives the nurses the possibility to offer support and information to the parents being early discharged. The app is experienced as a lifeline that connects the homes of the new parents with the hospital.

  1. Nurses’ Experience of Using an Application to Support New Parents after Early Discharge: An Intervention Study

    Dorthe Boe Danbjørg

    2015-01-01

    Full Text Available Background. A development towards earlier postnatal discharge presents a challenge to find new ways to provide information and support to families. A possibility is the use of telemedicine. Objective. To explore how using an app in nursing practice affects the nurses’ ability to offer support and information to postnatal mothers who are discharged early and their families. Design. Participatory design. An app with a chat, a knowledgebase, and automated messages was tried out between hospital and parents at home. Settings. The intervention took place on a postnatal ward with approximately 1,000 births a year. Participants. At the onset of the intervention, 17 nurses, all women, were working on the ward. At the end of the intervention, 16 nurses were employed, all women. Methods. Participant observation and two focus group interviews. The data analysis was inspired by systematic text condensation. Results. The nurses on the postnatal ward consider that the use of the app gives families easier access to timely information and support. Conclusions. The app gives the nurses the possibility to offer support and information to the parents being early discharged. The app is experienced as a lifeline that connects the homes of the new parents with the hospital.

  2. A preliminary study on the CT finding in SARS following hospital discharge

    Zhang Lieguang; Liu Jinxing; Chen Bihua; Jiang Songfeng

    2004-01-01

    Objective: To study the CT finding of chest in patient with SARS following hospital discharge. Methods: Thirty-six patients (11 men, 25 women; age range, 20-73 years; mean age, 39 years) with confirmed SARS underwent follow-up spiral CT. The scans were obtained on average 187 days (range from 152 days to 225 days) after onset of symptoms. Patients were assigned to group 1 (with heavy SARS, n=19) and group 2 (with common SARS, n=17) for analysis. The chest X-ray films of the 36 patients in fastigium of film were retrospectively reviewed. Results: 58.33% (21 of 36) cases are normal on the CT of thorax. In group 1 42.11% (8 of 19) cases and in group 2 76.47%(13 of 17) cases. In group 1: 31.58%(6 of 19) cases present diffuse ground-glass opacification, 21.05% (4 of 19) cases present multi-patch ground-glass opacification, 5.26% (1 of 19) cases present local ground-glass opacification in single lobar, 31.58% (6 of 19) cases present intralobular interstitial thickening and/or interlobular septal thickening, 5.26% (1 of 19) present subpleural lines, 5.26% (1 of 19) present honeycombing, 5.26% (1 of 19) cases present bullae; In group 2: 11.76% (2 of 17) cases present local ground-glass opacification, 11.76%(2 of 17) cases present intralobular interstitial thickening and/or interlobular septal thickening, 5.88%(1 of 17) cases present organized pneumonia. In group 1, 73.68% (14/19) cases in fastigium of film present large areas of lung consolidation and diffuse ground-glass opacification. Conclusion: Most of the healing SARS cases after certain time are normal on the CT finding of thorax. Part of them remain manifests such as ground-glass opacification, intralobular interstitial thickening and/or interlobular septal thickening, subpleural lines, honeycombing, traction bronchiectasis, organized pneumonia and bullae. They relate to severeness of the lesion of the lung in fastigium of film. Such finding can last for long time and probably fibrosis can be developed. (authors)

  3. Atmospheric-pressure electric discharge as an instrument of chemical activation of water solutions

    Rybkin, V. V.; Shutov, D. A.

    2017-11-01

    Results of experimental studies and numerical simulations of physicochemical characteristics of plasmas generated in different types of atmospheric-pressure discharges (pulsed streamer corona, gliding electric arc, dielectric barrier discharge, glow-discharge electrolysis, diaphragmatic discharge, and dc glow discharge) used to initiate various chemical processes in water solutions are analyzed. Typical reactor designs are considered. Data on the power supply characteristics, plasma electron parameters, gas temperatures, and densities of active particles in different types of discharges excited in different gases and their dependences on the external parameters of discharges are presented. The chemical composition of active particles formed in water is described. Possible mechanisms of production and loss of plasma particles are discussed.

  4. Study of the transport parameters of cloud lightning plasmas

    Chang, Z. S.; Yuan, P.; Zhao, N.

    2010-01-01

    Three spectra of cloud lightning have been acquired in Tibet (China) using a slitless grating spectrograph. The electrical conductivity, the electron thermal conductivity, and the electron thermal diffusivity of the cloud lightning, for the first time, are calculated by applying the transport theory of air plasma. In addition, we investigate the change behaviors of parameters (the temperature, the electron density, the electrical conductivity, the electron thermal conductivity, and the electron thermal diffusivity) in one of the cloud lightning channels. The result shows that these parameters decrease slightly along developing direction of the cloud lightning channel. Moreover, they represent similar sudden change behavior in tortuous positions and the branch of the cloud lightning channel.

  5. Simulation studies of the extraction region from glow discharge ion sources

    Abdelrahman, M.M.

    2012-01-01

    This paper studies the influence of various parameters and conditions on the performance of an ion-beam extraction system, the trajectories of the particles in the beam being simulated by a commercial software (SIMION 3D). Space-charge effects are accounted for and criteria allowing optimization of the system are proposed. Ion beam trajectories with and without space charge have been determined and, from the results, optimum extraction conditions have been deduced. Simulation of singly charged ion trajectories for a concave meniscus with 3.5 mm curvature radius was studied with and without space charge has been done using a singly charge argon ion trajectories. Firstly, for a concave meniscus with 3.5 mm curvature radius, the influence of the current density on the ion beam shape was investigated. Furthermore, influence of the extraction voltage applied to the extraction electrode on the ion beam envelope was studied. Finally, the influence of the extraction gap width on the ion beam envelope was also studied

  6. Experimental study of heating scheme effect on the inner divertor power footprint widths in EAST lower single null discharges

    Deng, G. Z.; Xu, J. C.; Liu, X.; Liu, X. J.; Liu, J. B.; Zhang, H.; Liu, S. C.; Chen, L.; Yan, N.; Feng, W.; Liu, H.; Xia, T. Y.; Zhang, B.; Shao, L. M.; Ming, T. F.; Xu, G. S.; Guo, H. Y.; Xu, X. Q.; Gao, X.; Wang, L.

    2018-04-01

    A comprehensive work of the effects of plasma current and heating schemes on divertor power footprint widths is carried out in the experimental advanced superconducting tokamak (EAST). The divertor power footprint widths, i.e., the scrape-off layer heat flux decay length λ q and the heat spreading S, are crucial physical and engineering parameters for fusion reactors. Strong inverse scaling of λ q and S with plasma current have been demonstrated for both neutral beam (NB) and lower hybrid wave (LHW) heated L-mode and H-mode plasmas at the inner divertor target. For plasmas heated by the combination of the two kinds of auxiliary heating schemes (NB and LHW), the divertor power widths tend to be larger in plasmas with higher ratio of LHW power. Comparison between experimental heat flux profiles at outer mid-plane (OMP) and divertor target for NB heated and LHW heated L-mode plasmas reveals that the magnetic topology changes induced by LHW may be the main reason to the wider divertor power widths in LHW heated discharges. The effect of heating schemes on divertor peak heat flux has also been investigated, and it is found that LHW heated discharges tend to have a lower divertor peak heat flux compared with NB heated discharges under similar input power. All these findings seem to suggest that plasmas with LHW auxiliary heating scheme are better heat exhaust scenarios for fusion reactors and should be the priorities for the design of next-step fusion reactors like China Fusion Engineering Test Reactor.

  7. Do families after early postnatal discharge need new ways to communicate with the hospital? A feasibilility study.

    Danbjørg, Dorthe Boe; Wagner, Lis; Clemensen, Jane

    2014-06-01

    the length of the postnatal hospital stay in Denmark as well as globally has been radically reduced over the past 10-20 years and this raises the challenge of finding new ways of providing observation and support to families discharged early, that they otherwise would be provided as inpatients. this study is to identify the nursing support needs of new parents and their infants during the first seven days post partum, by drawing on the experiences of all stakeholders' in early postnatal discharge from hospital, and thereby gaining new knowledge to investigate further whether telemedicine is a viable option in providing the required support. this article describes the first phase of a participatory design process. A qualitative approach guided the research process and the data analysis. Data were collected from participant observation, qualitative interviews with the new parents, focus groups interviews and a workshop attended by the new parents and health-care professionals. the total number of participants in this study was 37; nineteen parents and 18 health-care professionals from one hospital and three municipalities in Denmark. the investigation findings highlighted, amongst other aspects, the importance of individualised postnatal follow-up in which families have increased access to the health-care professionals and are provided with timely information tailored to their specific needs. the present study underscored that the families experiencing early discharge were not provided with seamless individualised follow-up support. They requested more availability from the health-care system to respond to their concerns and questions during the postnatal period. They experienced a barrier in attempting to contact health-care professionals following hospital discharge and they asked for new ways to communicate that would eliminate that barrier and meet their needs for more individualised and timely information and guidance. Copyright © 2013 Elsevier Ltd. All rights

  8. 'Delayed discharges and boarders': a 2-year study of the relationship between patients experiencing delayed discharges from an acute hospital and boarding of admitted patients in a crowded ED.

    Mustafa, Farah; Gilligan, Peadar; Obu, Deborah; O'Kelly, Patrick; O'Hea, Eimear; Lloyd, Catherine; Kelada, Sherif; Heffernan, Attracta; Houlihan, Patricia

    2016-09-01

    Many believe that hospital crowding manifesting in the ED with the boarding of admitted patients is a result of significant numbers of acute hospital beds being occupied by patients awaiting discharge to nursing homes, step-down facilities or home with or without additional support. This observational study was performed to establish the actual relationship between boarders in the ED and patients experiencing delayed discharge. Data relating to the number of patients in the ED and their points in their patient pathway were entered into a logbook on a daily basis by the most senior doctor on duty. 630 days of observations of patients boarded in the ED were compared with the number of inpatients with delayed discharges, obtained from the hospital information system, to see if large numbers of inpatients with delayed discharges are associated with crowding in the ED. Two years of data showed an annual ED census of more than 47 000, with a daily mean ED admission rate of 29.85 patients and a daily mean ED boarding figure of 29 patients. A mean of 15.4% of the 823 hospital beds was occupied by patients with delayed discharges, and the hospital ran at, or near, full capacity (99%-105%) all the time. Results obtained highlighted a statistically significant relationship between delayed discharges in the hospital and ED crowding as a result of boarders (p value<0.001, with a regression coefficient of 0.16, 95% CI 0.12 to 0.20). The study also showed that the number of boarders was related to the number of ED admissions in the preceding 24 hours (p=0.036, with a regression coefficient of 0.14, 95% CI 0.05 to 0.28). Delayed hospital discharges significantly contribute to crowding in the ED. Healthcare systems should target timely discharge of inpatients experiencing delayed discharge in an urgent and efficient manner to improve timely access to acute hospital beds for patients requiring emergency admission. Published by the BMJ Publishing Group Limited. For permission

  9. A study of the transient plasma potential in a pulsed bi-polar dc magnetron discharge

    Bradley, J W; Karkari, S K; Vetushka, A

    2004-01-01

    The temporal evolution of the plasma potential, V p , in a pulsed dc magnetron plasma has been determined using the emissive probe technique. The discharge was operated in the 'asymmetric bi-polar' mode, in which the discharge voltage changes polarity during part of the pulse cycle. The probe measurements, with a time-resolution of 20 ns or better, were made along a line above the racetrack, normal to the plane of the cathode target, for a fixed frequency (100 kHz), duty cycle (50%), argon pressure (0.74 Pa) and discharge power (583 W). At all the measured positions, V p was found to respond to the large and rapid changes in the cathode voltage, V d , during the different phases of the pulse cycle, with V p always more positive than V d . At a typical substrate position (>80 mm from the target), V p remains a few volts above the most positive surface in the discharge at all times. In the 'on' phase of the pulse, the measurements show a significant axial electric field is generated in the plasma, with the plasma potential dropping by a total of about 30 V over a distance of 70 mm, from the bulk plasma to a position close to the beginning of the cathode fall. This is consistent with measurements made in the dc magnetron. During the stable 'reverse' phase of the discharge, for distances greater than 18 mm from the target, the axial electric field is found to collapse, with V p elevated uniformly to about 3 V above V d . Between the target and this field-free region an ion sheath forms, and the current flowing to the target is still an ion current in this 'reverse' period. During the initial 200 ns of the voltage 'overshoot' phase (between 'on' and 'reverse' phases), V d reached a potential of +290 V; however, close to the target, V p was found to attain a much higher value, namely +378 V. Along the line of measurement, the axial electric field reverses in direction in this phase, and an electron current of up to 9 A flows to the target. The spatial and temporal

  10. A study on self-excited sloshing due to the fluid discharge over a flexible weir

    Nagakura, Hiroshi; Kaneko, Shigehiko.

    1995-01-01

    An analytical model for the fluid-elastic instability as observed in Super-Phenix-1 LMFBR is proposed. This fluid-structure system is constituted by the flexible weir and adjoining fluid plenums, and the fluid is discharged from the upstream plenum to the downstream plenum over a flexible weir. The characteristic equation of the system is derived for the case in which the weir vibrates at the frequency of the downstream plenum sloshing. The effects of the fluid level difference between the upstream and the downstream plenum and weir rigidity are examined, and the mechanism for instability is discussed. (author)

  11. Production and study of high intensity discharges; Production et etude de decharges a forte intensite

    Breton, C.; Charbon, J.; Hubert, P.; Vendryes, G.; Yvon, P. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    High intensity discharges have been induced in a pyrex toroid filled with argon or deuterium at low pressure. An attempt was made to stabilise the ring of plasma by the joint action of a metal screen and a longitudinal magnetic field. Penetrating X-ray have been observed under certain conditions. (author) [French] Des decharges a forte intensite ont ete induites dans une tore en pyrex rempli d'argon ou de deuterium sous basse pression. On a cherche a stabiliser l'anneau de plasma par l'action conjuguee d'un champ magnetique longitudinal. Un rayon X penetrant a ete observe dans certaines conditions. (auteur)

  12. Production and study of high intensity discharges; Production et etude de decharges a forte intensite

    Breton, C; Charbon, J; Hubert, P; Vendryes, G; Yvon, P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1957-07-01

    High intensity discharges have been induced in a pyrex toroid filled with argon or deuterium at low pressure. An attempt was made to stabilise the ring of plasma by the joint action of a metal screen and a longitudinal magnetic field. Penetrating X-ray have been observed under certain conditions. (author) [French] Des decharges a forte intensite ont ete induites dans une tore en pyrex rempli d'argon ou de deuterium sous basse pression. On a cherche a stabiliser l'anneau de plasma par l'action conjuguee d'un champ magnetique longitudinal. Un rayon X penetrant a ete observe dans certaines conditions. (auteur)

  13. Study of stability of dc glow discharges with the use of Comsol Multiphysics software

    Almeida, P G C; Benilov, M S; Faria, M J [Departamento de Fisica, Universidade da Madeira, Largo do Municipio, 9000 Funchal (Portugal)

    2011-10-19

    Stability of different axially symmetric modes of current transfer in dc glow discharges is investigated in the framework of the linear stability theory with the use of Comsol Multiphysics software. Conditions of current-controlled microdischarges in xenon are treated as an example. Both real and complex eigenvalues have been detected, meaning that perturbations can vary with time both monotonically and with oscillations. In general, results given by the linear stability theory confirm intuitive concepts developed in the literature and conform to the experiment. On the other hand, suggestions are provided for further experimental and theoretical work.

  14. Post-discharge body weight and neurodevelopmental outcomes among very low birth weight infants in Taiwan: A nationwide cohort study.

    Chung-Ting Hsu

    Full Text Available Premature infants are at high risk for developmental delay and cognitive dysfunction. Besides medical conditions, growth restriction is regarded as an important risk factor for cognitive and neurodevelopmental dysfunction throughout childhood and adolescence and even into adulthood. In this study, we analyzed the relationship between post-discharge body weight and psychomotor development using a nationwide dataset.This was a nationwide cohort study conducted in Taiwan. Total of 1791 premature infants born between 2007 and 2011 with a birth weight of less than 1500 g were enrolled into this multi-center study. The data were obtained from the Taiwan Premature Infant Developmental Collaborative Study Group. The growth and neurodevelopmental evaluations were performed at corrected ages of 6, 12 and 24 months. Post-discharge failure to thrive was defined as a body weight below the 3rd percentile of the standard growth curve for Taiwanese children by the corrected age.The prevalence of failure to thrive was 15.8%, 16.9%, and 12.0% at corrected ages of 6, 12, and 24 months, respectively. At corrected ages of 24 months, 12.9% had low Mental Developmental Index (MDI scores (MDI<70, 17.8% had low Psychomotor Developmental Index (PDI scores (PDI<70, 12.7% had cerebral palsy, and 29.5% had neurodevelopmental impairment. Post-discharge failure to thrive was significantly associated with poor neurodevelopmental outcomes. After controlling for potential confounding factors (small for gestational age, extra-uterine growth retardation at discharge, cerebral palsy, gender, mild intraventricular hemorrhage, persistent pulmonary hypertension of newborn, respiratory distress syndrome, chronic lung disease, hemodynamic significant patent ductus arteriosus, necrotizing enterocolitis, surfactant use and indomethacin use, post-discharge failure to thrive remained a risk factor.This observational study observed the association between lower body weight at corrected age

  15. Parameter motivated mutual correlation analysis: Application to the study of currency exchange rates based on intermittency parameter and Hurst exponent

    Cristescu, Constantin P.; Stan, Cristina; Scarlat, Eugen I.; Minea, Teofil; Cristescu, Cristina M.

    2012-04-01

    We present a novel method for the parameter oriented analysis of mutual correlation between independent time series or between equivalent structures such as ordered data sets. The proposed method is based on the sliding window technique, defines a new type of correlation measure and can be applied to time series from all domains of science and technology, experimental or simulated. A specific parameter that can characterize the time series is computed for each window and a cross correlation analysis is carried out on the set of values obtained for the time series under investigation. We apply this method to the study of some currency daily exchange rates from the point of view of the Hurst exponent and the intermittency parameter. Interesting correlation relationships are revealed and a tentative crisis prediction is presented.

  16. Fundamental studies on initiation and evolution of multi-channel discharges and their application to next generation pulsed power machines.

    Schwarz, Jens; Savage, Mark E.; Lucero, Diego Jose; Jaramillo, Deanna M.; Seals, Kelly Gene; Pitts, Todd Alan; Hautzenroeder, Brenna M.; Laine, Mark Richard; Karelitz, David B.; Porter, John L.

    2014-09-01

    Future pulsed power systems may rely on linear transformer driver (LTD) technology. The LTD's will be the building blocks for a driver that can deliver higher current than the Z-Machine. The LTD's would require tens of thousands of low inductance ( %3C 85nH), high voltage (200 kV DC) switches with high reliability and long lifetime ( 10 4 shots). Sandia's Z-Machine employs 36 megavolt class switches that are laser triggered by a single channel discharge. This is feasible for tens of switches but the high inductance and short switch life- time associated with the single channel discharge are undesirable for future machines. Thus the fundamental problem is how to lower inductance and losses while increasing switch life- time and reliability. These goals can be achieved by increasing the number of current-carrying channels. The rail gap switch is ideal for this purpose. Although those switches have been extensively studied during the past decades, each effort has only characterized a particular switch. There is no comprehensive understanding of the underlying physics that would allow predictive capability for arbitrary switch geometry. We have studied rail gap switches via an extensive suite of advanced diagnostics in synergy with theoretical physics and advanced modeling capability. Design and topology of multichannel switches as they relate to discharge dynamics are investigated. This involves electrically and optically triggered rail gaps, as well as discrete multi-site switch concepts.

  17. Mozart K.448 listening decreased seizure recurrence and epileptiform discharges in children with first unprovoked seizures: a randomized controlled study.

    Lin, Lung-Chang; Lee, Mei-Wen; Wei, Ruey-Chang; Mok, Hin-Kiu; Yang, Rei-Cheng

    2014-01-13

    Increasing numbers of reports show the beneficial effects of listening to Mozart music in decreasing epileptiform discharges as well as seizure frequency in epileptic children. There has been no effective method to reduce seizure recurrence after the first unprovoked seizure until now. In this study, we investigated the effect of listening to Mozart K.448 in reducing the seizure recurrence rate in children with first unprovoked seizures. Forty-eight children who experienced their first unprovoked seizure with epileptiform discharges were included in the study. They were randomly placed into treatment (n = 24) and control (n = 24) groups. Children in the treatment group listened to Mozart K.448 daily before bedtime for at least six months. Two patients in the treatment group were excluded from analysis due to discontinuation intervention. Finally, forty-six patients were analyzed. Most of these patients (89.1%) were idiopathic in etiology. Seizure recurrence rates and reduction of epileptiform discharges were compared. The average follow-up durations in the treatment and control groups were 18.6 ± 6.6 and 20.1 ± 5.1 months, respectively. The seizure recurrence rate was estimated to be significantly lower in the treatment group than the control group over 24 months (37.2% vs. 76.8%, p = 0.0109). Significant decreases in epileptiform discharges were also observed after 1, 2, and 6 months of listening to Mozart K.448 when compared with EEGs before listening to music. There were no significant differences in gender, mentality, seizure type, and etiology between the recurrence and non-recurrence groups. Although the case number was limited and control music was not performed in this study, the study revealed that listening to Mozart K.448 reduced the seizure recurrence rate and epileptiform discharges in children with first unprovoked seizures, especially of idiopathic etiology. We believe that Mozart K.448 could be a promising alternative treatment in patients with

  18. Permanently split capacitor motor-study of the design parameters

    Sarac, Vasilija; Stefanov, Goce

    2017-09-01

    Paper analyzes the influence of various design parameters on torque of permanently split capacitor motor. Motor analytical model is derived and it is used for calculating the performance characteristics of basic motor model. The acquired analytical model is applied in optimization software that uses genetic algorithms (GA) as an optimization method. Optimized motor model with increased torque is derived by varying three motor parameters in GA program: winding turns ratio, average air gap flux density and motor stack length. Increase of torque has been achieved for nominal operation but also at motor starting. Accuracy of the derived models is verified by Simulink. The acquired values of several motor parameters from transient characteristics of Simulink models are compared with the corresponding values obtained from analytical models of both motors, basic and optimized. Numerical analysis, based on finite element method (FEM), is also performed for both motor models. As a result of the FEM analysis, magnetic flux density in motor cross-section is calculated and adequate conclusions are derived in relation to core saturation and air gap flux density in both motor models.

  19. Development of a see-through hollow cathode discharge lamp for (Li/Ne) optogalvanic studies

    Saini, V. K.; Kumar, P.; Sarangpani, K. K.; Dixit, S. K.; Nakhe, S. V.

    2017-09-01

    Development of a demountable and see-through hollow cathode (HC) discharge lamp suitable for optogalvanic (OG) spectroscopy is described. The design of the HC lamp is simple, compact, and inexpensive. Lithium, investigated rarely by the OG method, is selected for cathode material as its isotopes are important for nuclear industry. The HC lamp is characterized electrically and optically for discharge oscillations free OG effect. Strong OG signals of lithium as well as neon (as buffer gas) are produced precisely upon copper vapor laser pumped tunable dye laser irradiation. The HC lamp is capable of generating a clean OG resonance spectrum in the available dye laser wavelength scanning range (627.5-676 nm) obtained with 4-(Dicyanomethylene)-2-methyl-6-(4-dimethylaminostyryl)-4H-pyran dye. About 28 resonant OG lines are explicitly observed. Majority of them have been identified using j-l coupling scheme and assigned to the well-known neon transitions. One line that corresponds to wavelength near about 670.80 nm is assigned to lithium and resolved for its fine (2S1/2 → 2P1/2, 3/2) transitions. These OG transitions allow 0.33 cm-1 accuracy and can be used to supplement the OG transition data available from other sources to calibrate the wavelength of a scanning dye laser with precision at atomic levels.

  20. Study of internal transport barriers in the initial phase of Ohmic discharges in TUMAN-3M

    Askinazi, L G; Bulanin, V V; Vildjunas, M I; Golant, V E; Gorokhov, M V; Kornev, V A; Krikunov, S V; Lebedev, S V; Petrov, A V; Rozhdestvensky, V V; Tukachinsky, A S; Zhubr, N A

    2004-01-01

    A regime with electron heat confinement improvement was recently found in the initial phase of discharges in the TUMAN-3M tokamak. An internal transport barrier (ITB) formation in this regime was confirmed by Thomson scattering measurements and by transport modelling. Two possible reasons for the ITB formation are discussed in the paper: by reduction of turbulent transport in the presence of low magnetic shear or by plasma sheared rotation. It is demonstrated that low magnetic shear formation is possible in the current ramp-up phase of the Ohmic discharge. The low magnetic shear does not seem to be the only reason for the transport reduction. Results of Doppler reflectometry measurements of poloidal rotation of density fluctuations are presented. It is found that core confinement improvement correlates with the appearance of sheared rotation of the density fluctuations and with a burst of the MHD activity. The ITB formation in the regime seems to be a result of a combined action of reduced magnetic shear and plasma sheared rotation

  1. Some aspects of the study of gas-discharge plasma and production of high magnetic fields

    Novitskii, V.G.

    This collection is compiled from the papers presented in the section of MHD generators and superconducting devices at the Institute of Electromechanics Conference held in May 1965. The subjects discussed include three-phase plasmatrons, their operational characteristics, and the nature of the physical processes occurring in the arc chamber. The collection also contains the results of experimental and theoretical research on gas-discharge plasma, conduction phenomena in flowing gaseous plasmas, and energy balance and radiation in the case of gas-discharge plasma. It also considers the stability of arcs, the effect of the transverse magnetic field and gas flow on breakdown voltages, the electrode phenomena and the distribution of current on the electrodes. Results of research on the conditions of electric-arc contraction and the characteristics of a contracted arc are given. The problems associated with the production of high magnetic fields and the use of superconducting materials to this end are discussed. The experience gained in the design and fabrication of superconducting magnets and cryostats is described. The results of design calculations for magnetic systems of the Bitter type are also presented

  2. Interdisciplinary Team Collaboration during Discharge of Depressed Older Persons: A Norwegian Qualitative Implementation Study

    Anne Lise Holm

    2013-01-01

    Full Text Available In order to deliver effective care, it is necessary to organise interdisciplinary activities for older persons who suffer from depressive disorders. This paper evaluated the interdisciplinary team members’ perceptions of cooperation in the discharge planning of depressed older persons based on the Chronic Care Model (CCM. A qualitative implementation design was used, data were collected by means of multistage focus groups, and a thematic analysis was performed. Three themes emerged: lack of effective team leadership in the community, the need to change the delivery system, and enhancing self-management support for depressed older persons as well as the participation of their families. It was concluded that nurse managers must find ways of supporting the depressed older persons by better structuring the care, increasing cooperation with organisational leadership, and creating an environment characterised by trust and mutual respect. Distrust can have serious implications for discharge planning collaboration. The development of a common vision of transparency in the organization is important as is a policy of change among leadership and in clinical practice.

  3. Angioplasty and stent - heart - discharge

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  4. Radiological discharges

    Woodliffe, J.

    1990-01-01

    Current practice of North Sea States on the discharge and disposal of liquid radioactive wastes to the North Sea are based on the declaration issued at the Second International Conference on the Protection of the North Sea, known as the London Declaration. This has three main points the first of which emphasises the application of the Best Available Technology to protect the North Sea, the second provides a framework on which future controls on radioactive discharges should be based. The third identifies two parts of the framework; to take into account the recommendations of international organizations and that any repositories of radioactive waste which are built should not pollute the North Sea. This chapter looks at how the concensus based on the London Declaration is working, gauges the progress made in the implementation of the policy goal, identifies existing and future areas for concern and proposes ways of strengthening the control of radioactive discharges. The emphasis is on the United Kingdom practice and regulations for liquid wastes, most of which comes from the Sellafield Reprocessing Plant. (author)

  5. Safe start at home: what parents of newborns need after early discharge from hospital - a focus group study.

    Kurth, Elisabeth; Krähenbühl, Katrin; Eicher, Manuela; Rodmann, Susanne; Fölmli, Luzia; Conzelmann, Cornelia; Zemp, Elisabeth

    2016-03-08

    The length of postpartum hospital stay is decreasing internationally. Earlier hospital discharge of mothers and newborns decreases postnatal care or transfers it to the outpatient setting. This study aimed to investigate the experiences of new parents and examine their views on care following early hospital discharge. Six focus group discussions with new parents (n = 24) were conducted. A stratified sampling scheme of German and Turkish-speaking groups was employed. A 'playful design' method was used to facilitate participants communication wherein they used blocks and figurines to visualize their perspectives on care models The visualized constructions of care models were photographed and discussions were audio-recorded and transcribed verbatim. Text and visual data was thematically analyzed by a multi-professional group and findings were validated by the focus group participants. Following discharge, mothers reported feeling physically strained during recuperating from birth and initiating breastfeeding. The combined requirements of infant and self-care needs resulted in a significant need for practical and medical support. Families reported challenges in accessing postnatal care services and lacking inter-professional coordination. The visualized models of ideal care comprised access to a package of postnatal care including monitoring, treating and caring for the health of the mother and newborn. This included home visits from qualified midwives, access to a 24-h helpline, and domestic support for household tasks. Participants suggested that improving inter-professional networks, implementing supervisors or a centralized coordinating center could help to remedy the current fragmented care. After hospital discharge, new parents need practical support, monitoring and care. Such support is important for the health and wellbeing of the mother and child. Integrated care services including professional home visits and a 24-hour help line may help meet the needs of

  6. Numerical study of the dielectric liquid around an electrical discharge generated vapor bubble in ultrasonic assisted EDM.

    Shervani-Tabar, Mohammad T; Mobadersany, Nima

    2013-07-01

    In electrical discharge machining due to the electrical current, very small bubbles are created in the dielectric fluid between the tool and the workpiece. Increase of the number of bubbles and their growth in size generate a single bubble. The bubble has an important role in electrical discharge machining. In this paper the effect of ultrasonic vibration of the tool and the velocity fields and pressure distribution in the dielectric fluid around the bubble in the process of electrical discharge machining are studied numerically. The boundary integral equation method is applied for the numerical solution of the problem. It is shown that ultrasonic vibration of the tool has great influence on the evolution of the bubble, fluid behavior and the efficiency of the machining in EDM. At the last stages of the collapse phase of the bubble, a liquid jet develops on the bubble which has different shapes. Due to the different cases, and a high pressure region appears just near the jet of the bubble. Also the fluid particles have the highest relative velocity just near the liquid jet of the bubble. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Study of efficacy in a mercury-free flat discharge fluorescent lamp using a zero-dimensional positive column model

    Shiga, T; Boeuf, J P; Mikoshiba, S

    2003-01-01

    A zero-dimensional model of the positive column in Ar/Ne/Xe gas mixtures has been developed to help understand the measured dependence of the efficacy on operating conditions in a mercury-free flat fluorescent lamp in a dielectric barrier geometry. The experimental conditions are such that the radiation from the discharge is homogeneous over most of the discharge voltage. The model uses as input the discharge current waveform from the experiments, and it yields the time variations of the mean electron energy and the species densities. From these quantities we calculate the number of vacuum ultraviolet (VUV) photons emitted by the xenon resonance atoms and excimers during one current pulse and the efficiency for generation of VUV radiation in the positive column, which are compared with the measured luminance and efficacy for various voltages, pulse intervals, and lamp sizes. Over the range of conditions studied, we find that most electrical energy dissipated in xenon excitation is converted to VUV radiation; ...

  8. Absorption spectroscopic studies of carbon dioxide conversion in a low pressure glow discharge using tunable infrared diode lasers

    Hempel, F; Roepcke, J; Miethke, F; Wagner, H-E

    2002-01-01

    The time and spatial dependence of the chemical conversion of CO 2 to CO were studied in a closed glow discharge reactor (p = 50 Pa, I = 2-30 mA) consisting of a small plasma zone and an extended stationary afterglow. Tunable infrared diode laser absorption spectroscopy has been applied to determine the absolute ground state concentrations of CO and CO 2 . After a certain discharge time an equilibrium of the concentrations of both species could be observed. The spatial dependence of the equilibrium CO concentration in the afterglow was found to be varying less than 10%. The feed gas was converted to CO more predominantly between 43% and 60% with increasing discharge current, forming so-called quasi-equilibrium states of the stable reaction products. The formation time of the stable gas composition also decreased with the current. For currents higher than 10 mA the conversion rate of CO 2 to CO was estimated to be 1.2x10 13 molecules J -1 . Based on the experimental results, a plasma chemical modelling has been established

  9. Study on the surface reaction of LaNi{sub 5} alloy during discharge process in KOH solution

    Tan Zuxian [Department of Chemistry, Wuhan University, Wuhan 430072 (China); Yang Yifu [Department of Chemistry, Wuhan University, Wuhan 430072 (China)]. E-mail: yang-y-f1@vip.sina.com; Jiang Fengshan [Department of Chemistry, Wuhan University, Wuhan 430072 (China); Shao Huixia [Department of Chemistry, Wuhan University, Wuhan 430072 (China)

    2006-10-05

    A new method for studying surface reaction of LaNi{sub 5} absorbing alloy in KOH solution (pH 12) was established. It is based on tip-substrate voltammetry of scanning electrochemical microscopy (SECM) where the tip faradic current is recorded while scanning the substrate potential. The Pt electrode is selected as tip electrode, and the Pt oxide formation-reduction is used as a pH-dependent reaction while the tip potential is held at a constant value. As substrate surface reactions proceed, the pH of solution can be changed, and then the tip faradic current is recorded. The mechanism of discharge process of LaNi{sub 5} alloy was analyzed by comparing the tip current (I {sub tip}) versus substrate potential (E {sub sub}) curve, which reflects the exchange of H{sup +} or OH{sup -} between the alloy surface and the solution, with the substrate current (I {sub sub}) versus substrate potential (E {sub sub}) curve, which reflects the exchange of electron on the LaNi{sub 5} alloy surface. The results showed that the OH{sup -} adsorption process is occurred before the electron transfer process during discharge process, and the adsorptive OH{sup -} helps the oxidation of adsorbed hydrogen atom on the alloy surface. A quantitative assessment for the maximum changes of pH during discharge process is also proposed, and the variation as large as 2.65 pH unit was detected.

  10. Study on the surface reaction of LaNi{sub 5} alloy during discharge process in KOH solution

    Tan, Zuxian; Yang, Yifu; Jiang, Fengshan; Shao, Huixia [Wuhan University, Wuhan (China). Department of Chemistry

    2006-10-05

    A new method for studying surface reaction of LaNi{sub 5} absorbing alloy in KOH solution (pH 12) was established. It is based on tip-substrate voltammetry of scanning electrochemical microscopy (SECM) where the tip faradic current is recorded while scanning the substrate potential. The Pt electrode is selected as tip electrode, and the Pt oxide formation-reduction is used as a pH-dependent reaction while the tip potential is held at a constant value. As substrate surface reactions proceed, the pH of solution can be changed, and then the tip faradic current is recorded. The mechanism of discharge process of LaNi{sub 5} alloy was analyzed by comparing the tip current (I{sub tip}) versus substrate potential (E{sub sub}) curve, which reflects the exchange of H{sup +} or OH{sup -} between the alloy surface and the solution, with the substrate current (I{sub sub}) versus substrate potential (E{sub sub}) curve, which reflects the exchange of electron on the LaNi{sub 5} alloy surface. The results showed that the OH{sup -} adsorption process is occurred before the electron transfer process during discharge process, and the adsorptive OH{sup -} helps the oxidation of adsorbed hydrogen atom on the alloy surface. A quantitative assessment for the maximum changes of pH during discharge process is also proposed, and the variation as large as 2.65 pH unit was detected. (author)

  11. Influence of superstition on the date of hospital discharge and medical cost in Japan: retrospective and descriptive study.

    Hira, K; Fukui, T; Endoh, A; Rahman, M; Maekawa, M

    To determine the influence of superstition about Taian (a lucky day)-Butsumetsu (an unlucky day) on decision to leave hospital. To estimate the costs of the effect of this superstition. Retrospective and descriptive study. University hospital in Kyoto, Japan. Patients who were discharged alive from Kyoto University Hospital from 1 April 1992 to 31 March 1995. Mean number, age, and hospital stay of patients discharged on each day of six day cycle. The mean number, age, and hospital stay of discharged patients were highest on Taian and lowest on Butsumetsu (25.8 v 19.3 patients/day, P=0.0001; 43.9 v 41.4 years, P=0.0001; and 43.1 v 33.3 days, P=0.0001 respectively). The effect of this difference on the hospital's costs was estimated to be 7.4 million yen (¿31 000). The superstition influenced the decision to leave hospital, contributing to higher medical care costs in Japan. Although hospital stays need to be kept as short as possible to minimise costs, doctors should not ignore the possible psychological effects on patients' health caused by dismissing the superstition.

  12. Correction factors for photon spectrometry in nuclear parameters study

    Patrao, Karla Cristina de Souza

    2004-10-01

    The goal of this work was the determination, using metrologic severity, the factors of correction for coincidences XX, Xγ and γγ and the factors of transference of efficiency for use in gamma spectrometry. On this way, it was carried through by determination of nuclear parameters of a nuclide used in medicine diagnostic ( 201 Tl) and the standardization of two environmental samples, of regular and irregular geometry, proceeding from the residual (ashes and slag) from the nuclear industry. The results shows that this adopted methodology is valid, and it allows its application for many different nuclides, including complex decay schema nuclides, using only photons spectrometry techniques on semiconductor detectors. (author)

  13. Comparative study of radiation shielding parameters for bismuth borate glasses

    Kaundal, Rajinder Singh

    2016-01-01

    Melt and quench technique was used for the preparation of glassy samples of the composition x Bi 2 O 3- (1-x) B 2 O 3 where x= .05 to .040. XCOM computer program is used for the evaluation of gamma-ray shielding parameters of the prepared glass samples. Further the values of mass attenuation coefficients, effective atomic number and half value layer for the glassy samples have been calculated in the energy range from 1KeV to 100GeV. Rigidity of the glass samples have been analyzed by molar volume of the prepared glass samples. (author)

  14. Comparative study of radiation shielding parameters for bismuth borate glasses

    Kaundal, Rajinder Singh, E-mail: rajinder_apd@yahoo.com [Department of Physics, School of Physical Sciences, Lovely Professional University, Phagwara, Punjab (India)

    2016-07-15

    Melt and quench technique was used for the preparation of glassy samples of the composition x Bi{sub 2}O{sub 3-}(1-x) B{sub 2}O{sub 3} where x= .05 to .040. XCOM computer program is used for the evaluation of gamma-ray shielding parameters of the prepared glass samples. Further the values of mass attenuation coefficients, effective atomic number and half value layer for the glassy samples have been calculated in the energy range from 1KeV to 100GeV. Rigidity of the glass samples have been analyzed by molar volume of the prepared glass samples. (author)

  15. Comparative Study of Radiation Shielding Parameters for Bismuth Borate Glasses

    Kaundal, Rajinder Singh

    2016-01-01

    Melt and quench technique was used for the preparation of glassy samples of the composition x Bi2O3-(1-x) B2O3 where x= .05 to .040. XCOM computer program is used for the evaluation of gamma-ray shielding parameters of the prepared glass samples. Further the values of mass attenuation coefficients, effective atomic number and half value layer for the glassy samples have been calculated in the energy range from 1KeV to 100GeV. Rigidity of the glass samples have been analyzed by molar volume of...

  16. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  17. THE EVOLUTION OF HETERGENEOUS 'CLUMPY JETS': A PARAMETER STUDY

    Yirak, Kristopher; Schroeder, Ed; Frank, Adam; Cunningham, Andrew J.

    2012-01-01

    We investigate the role discrete clumps embedded in an astrophysical jet play on the jet's morphology and line emission characteristics. By varying clumps' size, density, position, and velocity, we cover a range of parameter space motivated by observations of objects such as the Herbig-Haro object HH 34. We here extend the results presented in Yirak et al., including how analysis of individual observations may lead to spurious sinusoidal variation whose parameters vary widely over time, owing chiefly to interactions between clumps. The goodness of fits, while poor in all simulations, are best when clump-clump collisions are minimal. Our results indicate that a large velocity dispersion leads to a clump-clump collision-dominated flow which disrupts the jet beam. Finally, we present synthetic emission images of Hα and [S II] and note an excess of [S II] emission along the jet length as compared to observations. This suggests that observed beams undergo earlier processing, if they are present at all.

  18. Who cares for the carers at hospital discharge at the end of life? A qualitative study of current practice in discharge planning and the potential value of using The Carer Support Needs Assessment Tool (CSNAT) Approach.

    Ewing, Gail; Austin, Lynn; Jones, Debra; Grande, Gunn

    2018-05-01

    Carer factors prevent patients achieving timely and appropriate hospital discharge. There is a lack of research into interventions to support carers at hospital discharge. To explore whether and how family carers are currently supported during patient discharge at end of life; to assess perceived benefits, acceptability and feasibility of using The Carer Support Needs Assessment Tool (CSNAT) Approach in the hospital setting to support carers. Qualitative. Three National Health Service Trusts in England: focus groups with 40 hospital and community-based practitioners and 22 carer interviews about experiences of carer support during hospital discharge and views of The CSNAT Approach. Two workshops brought together 14 practitioners and five carers to discuss implementation issues. Framework analysis was conducted. Current barriers to supporting carers at hospital discharge were an organisational focus on patients' needs, what practitioners perceived as carers' often 'unrealistic expectations' of end-of-life caregiving at home and lack of awareness of patients' end-of-life situation. The CSNAT Approach was viewed as enabling carer support and addressing difficulties of discussing the realities of supporting someone at home towards end of life. Implementation in hospital required organisational considerations of practitioner workload and training. To enhance carer support, a two-stage process of assessment and support (hospital with community follow-up) was suggested using the CSNAT as a carer-held record to manage the transition. This study identifies a novel intervention, which expands the focus of discharge planning to include assessment of carers' support needs at transition, potentially preventing breakdown of care at home and patient readmissions to hospital.

  19. Feasibility Study for Electrical Discharge Machining of Large DU-Mo Castings

    Hill, Mary Ann; Dombrowski, David E.; Clarke, Kester Diederik; Forsyth, Robert Thomas; Aikin, Robert M.; Alexander, David John; Tegtmeier, Eric Lee; Robison, Jeffrey Curt; Beard, Timothy Vance; Edwards, Randall Lynn; Mauro, Michael Ernest; Scott, Jeffrey E.; Strandy, Matthew Thomas

    2016-01-01

    U-10 wt. % Mo (U-10Mo) alloys are being developed as low enrichment monolithic fuel for the CONVERT program. Optimization of processing for the monolithic fuel is being pursued with the use of electrical discharge machining (EDM) under CONVERT HPRR WBS 1.2.4.5 Optimization of Coupon Preparation. The process is applicable to manufacturing experimental fuel plate specimens for the Mini-Plate-1 (MP-1) irradiation campaign. The benefits of EDM are reduced machining costs, ability to achieve higher tolerances, stress-free, burr-free surfaces eliminating the need for milling, and the ability to machine complex shapes. Kerf losses are much smaller with EDM (tenths of mm) compared to conventional machining (mm). Reliable repeatability is achievable with EDM due to its computer-generated machining programs.

  20. Feasibility Study for Electrical Discharge Machining of Large DU-Mo Castings

    Hill, Mary Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Dombrowski, David E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Clarke, Kester Diederik [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Forsyth, Robert Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Aikin, Robert M. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Alexander, David John [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Tegtmeier, Eric Lee [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Robison, Jeffrey Curt [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Beard, Timothy Vance [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Edwards, Randall Lynn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Mauro, Michael Ernest [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Scott, Jeffrey E. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division; Strandy, Matthew Thomas [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). SIGMA Division

    2016-10-31

    U-10 wt. % Mo (U-10Mo) alloys are being developed as low enrichment monolithic fuel for the CONVERT program. Optimization of processing for the monolithic fuel is being pursued with the use of electrical discharge machining (EDM) under CONVERT HPRR WBS 1.2.4.5 Optimization of Coupon Preparation. The process is applicable to manufacturing experimental fuel plate specimens for the Mini-Plate-1 (MP-1) irradiation campaign. The benefits of EDM are reduced machining costs, ability to achieve higher tolerances, stress-free, burr-free surfaces eliminating the need for milling, and the ability to machine complex shapes. Kerf losses are much smaller with EDM (tenths of mm) compared to conventional machining (mm). Reliable repeatability is achievable with EDM due to its computer-generated machining programs.

  1. A numerical simulation study on active species production in dense methane-air plasma discharge

    Gui, LI; Muyang, QIAN; Sanqiu, LIU; Huaying, CHEN; Chunsheng, REN; Dezhen, WANG

    2018-01-01

    Recently, low-temperature atmospheric pressure plasmas have been proposed as a potential type of ‘reaction carrier’ for the conversion of methane into value-added chemicals. In this paper, the multi-physics field coupling software of COMSOL is used to simulate the detailed discharge characteristics of atmospheric pressure methane-air plasma. A two-dimensional axisymmetric fluid model is constructed, in which 77 plasma chemical reactions and 32 different species are taken into account. The spatial density distributions of dominant charged ions and reactive radical species, such as {{{CH}}}4+, {{{CH}}}3+, {{{N}}}2+, {{{O}}}2+, H, O, CH3, and CH2, are presented, which is due to plasma chemical reactions of methane/air dissociation (or ionization) and reforming of small fragment radical species. The physicochemical mechanisms of methane dissociation and radical species recombination are also discussed and analyzed.

  2. Experimental study of discharging PCM ceiling panels through nocturnal radiative cooling

    Bourdakis, Eleftherios; Péan, Thibault Q.; Gennari, Luca

    PhotoVoltaic/Thermal (PV/T) panels were used for cooling water through the principle of nocturnal radiative cooling. This water was utilised for discharging Phase Change Material (PCM) which was embedded in ceiling panels in a climate chamber. Three different sets of flow rates were examined...... for the solar and the PCM loops, for five days each. The highest examined water flow rate (210 l/h) in the PCM loop provided the best thermal environment in the climate chamber, namely 92% of the occupancy time was within the range of Category III of Standard EN 15251. Although the lowest examined water flow...... rate (96 l/h) in the solar loop provided the highest average cooling power, due to the significant variations in the weather conditions during the three experimental cases, made it impossible to determine to which extent the difference in the cooling power is due to the different water flow rate...

  3. Analytical study of ozone generation in a single discharge in oxygen

    Hernandez A, A.O.

    1995-01-01

    The present thesis work, in the case of the equations description the generation ozone process, an atomic oxygen it was described, in the first part, the analysis of perturbative method used in [1] to solve this kind of equations, so on the solutions in the stationary and temporal cases were rensed by means of a constant flux velocity. The second part present the solutions to the sat dy state equations for constant mean flux velocity (Poiseuille form) at low pressures. Finally, the resulting equations were compared with other authors reports. [1] C. Gutierrez-Tapia, E. Camps and O. Olea-Cardoso, Perturbative method for ozone synthesis from oxygen in a single discharge. IEEE Trans. on Plasma Sci. 22(5) 979-985, 1994. (Author)

  4. Study of aerosol jet printing with dry nanoparticles synthesized by spark discharge

    Efimov, A. A.; Arsenov, P. V.; Volkov, I. A.; Urazov, M. N.; Ivanov, V. V.

    2017-11-01

    A new method of aerosol jet printing utilizing dry (solvent-free) airborne nanoparticles generated by spark discharge is proposed. This method was applied to fabricate thin conducting lines (60-160 μm) composed of silver nanoparticles on the surface of glass substrates. It has been demonstrated that the line width is determined by a sheath flow rate, while its thickness and cross-sectional area can be scaled up by a number of printing runs. The resistivity of printed lines after the annealing was found to be five times higher than that of bulk silver that is attributed to the porosity and the interparticle contact resistance. The proposed method holds promise for the application in technologies of printed electronics.

  5. Chemical and isotopic study of thermal springs and gas discharges from Sierra de Chiapas, Mexico

    Nencetti, A; Tassi, F; Vaselli, O [Department of Earth Sciences, Florence (Italy); Macias, J. L [Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, D.F. (Mexico); Magro, G [CNR-Institute of Geosciences and Earth Resources, Pisa (Italy); Capaccioni, B [Institute of Volcanology and Geochemistry, Urbino (Italy); Minissale, A [CNR-Institute of Geosciences and Earth Resources, Florence (Italy); Mora, J. C [Instituto de Geofisica, Universidad Nacional Autonoma de Mexico, D.F. (Mexico)

    2005-01-15

    Thermal water and gas discharges south-east of El Chichon volcano, Mexico are associated mainly with NW-SE oriented fault systems. Spring discharges include i) waters with Na-Cl composition and TDS>3000 mg/L; ii) waters with Ca-SO{sub 4} composition and TDS values between 1400 and 2300 mg/L; iii) waters with Na-Cl composition and TDS of 800 to 2400 mg/L and sulphate content up to 650 mg/L and iv) waters with Ca-HCO{sub 3} composition and low salinity (TDS <250mg/L). Most of these waters are associated with free-gas discharges of N{sub 2} (up to 93 % by vol.), CO{sub 2} (2.4 to 31.2 % by vol.) and Ar (up to 1.25 % by vol.) with a predominant meteoric origin. H{sub 2}S is present only in gas samplers collected at El Azufre (up to 1.1 % by vol.). The {delta}13C CO{sub 2} values are always below -9.7% (PDB) and suggest a partially biogenic origin for CO{sub 2}. Chemical and isotopic features of spring discharges indicate that fluid circulation in the Sierra de Chiapas is mainly regulated by meteoric waters that tend to infiltrate the upper and middle-Cretaceous carbonate units up to the lower Cretaceous-upper Jurassic evaporitic formations (by Lopez-Ramos, 1982). The latter provide the main source of the species in solution. No evidence for high-to-medium enthalpy systems at depth beneath the Sierra de Chiapas has been found. [Spanish] La Sierra de Chiapas localizada en el Sureste de Mexico, se caracteriza por la presencia de descargas de gas y agua. La mayoria de los manantiales termales se asocian a rocas volcanicas Terciarias a lo largo de fallas regionales con orientacion NOSE. Las descargas termales se dividen en cuatro grupos: i) aguas con composicion Na-Cl y Solidos Disueltos Totales (SDT) >3000 mg/L; ii) aguas con composicion Ca-SO{sub 4} y valores de SDT entre 1400 y 2300 mg/L; iii) aguas con composicion Na-Cl, bajos contenidos de SDT (800 2400 mg/L) y un contenido de sulfato alto (hasta 650 mg/L) y iv) aguas con una composicion Ca-HCO{sub 3} y salinidad baja

  6. Surface activation of cyclo olefin polymer by oxygen plasma discharge: a molecular dynamics study

    Soberon, Felipe

    2014-01-01

    Thermoplastic substrates made of cyclo olefin polymer (COP) are treated with oxygen plasma discharges to introduce polar groups at the surface. This is the first step in the process of surface functionalization of COP substrates used in biosensor devices. A molecular dynamics model of basic COP structure is implemented using the second-generation reactive empirical bond order (REBO) potentials for hydrocarbon–oxygen interactions. The model includes covalent bond and Van der Waals interactions. The bombardment of a COP surface with mono-energetic atomic oxygen ions, energy in the range 1-35 eV, is simulated and reported here. The dynamics of the substrate modification reveals that the substrate top layer is de-hydrogenated and subsequently builds up an oxygen–carbon matrix layer, ∼10 Å thick. Analysis of the modified substrates indicates that surface yield is predominantly peroxide groups. (paper)

  7. NATO Advanced Study Institute on Sprites, Elves and Intense Lightning Discharges

    Füllekrug, Martin; Rycroft, Michael J

    2006-01-01

    Particularly intense lightning discharges can produce transient luminous events above thunderclouds, termed sprites, elves and jets. These short lived optical emissions in the mesosphere can reach from the tops of thunderclouds up to the ionosphere; they provide direct evidence of coupling from the lower atmosphere to the upper atmosphere. Sprites are arguably the most dramatic recent discovery in solar-terrestrial physics. Shortly after the first ground based video recordings of sprites, observations on board the Space Shuttle detected sprites and elves occurring all around the world. These reports led to detailed sprite observations in North America, South America, Australia, Japan, and Europe. Subsequently, sprites were detected from other space platforms such as the International Space Station and the ROCSAT satellite. During the past 15 years, more than 200 contributions on sprites have been published in the scientific literature to document this rapidly evolving new research area.

  8. A population-based study of survival and discharge status for survivors after head injury

    Engberg, Aase Worså; Teasdale, T W

    2004-01-01

    -Meier survival functions were calculated for these two categories. Hospital records for a random sample of 389 survivors in 1997 after cranial fracture, acute brain lesion or chronical subdural haematoma, which occurred in 1982, 1987 and 1992 in patients aged 15 years or more at injury, were reviewed. Survivors...... the decreasing incidence with time, the point prevalence of survivors in 1997 after brain lesions occurring in 1982, 1987 or 1992 was nearly the same, averaging 8.4 per 100 000 of the population above age 14. Half of them were severe, as defined by initial Glasgow Coma Score .... There was no tendency with time of injury with regard to percentage occurrence of neurophysical, speech or mental deficits at discharge. The calculated number of candidates for rehabilitation of personal activities of daily life briefly after injury was 9.8 per 100 000 with cerebral lesion and 1.2 per 100 000...

  9. Study of electromagnetic noise influence on quench detection system under different discharge conditions for EAST

    Hu, Yanlan; Li, Jiangang; Shen, Biao; Lv, Huanyu; Xiao, Y.Z.

    2013-01-01

    Highlights: ► Reliable quench detection in EAST is a key issue for steady-state operation. ► The electromagnet noise interference associated with detection signals under different discharge conditions are evaluated. ► The effective measures have been realized on detection systems. ► Recently upgrade work has been done, especially for the optimization of ACS and false FSDS were reduced greatly. -- Abstract: EAST is the first Tokamak device whose toroidal and poloidal magnet are superconducting. The enormous magnetic field energy stored in the magnet system will transfer into thermal energy and cause the damage of superconducting magnet, if a quench happened. Therefore, reliable quench detection is a key issue for steady-state operation. In addition to electromagnetic noise from poloidal magnet fields and plasma current which will experience fast current ramp rate, radio frequency noise from heating system also have some interference on quench detection system to a certain degree. The most difficult point for quench detection system is required to have more detail evaluation on electromagnetic noise interference. Recently experiments have been carried out successfully in EAST device. The steady-state operation with 1 MA of plasma current and more than 100-s plasma duration has been obtained. In the paper, the electromagnetic noise interference on quench detection system under different discharge conditions are analyzed and relative process methods are also introduced. The technological experience and experimental data are significant for the constructing ITER and similar superconducting device have been mentioned which will supply significant technological experience and experimental data for constructing ITER and similar superconducting device

  10. Risk prediction of emergency department revisit 30 days post discharge: a prospective study.

    Shiying Hao

    Full Text Available Among patients who are discharged from the Emergency Department (ED, about 3% return within 30 days. Revisits can be related to the nature of the disease, medical errors, and/or inadequate diagnoses and treatment during their initial ED visit. Identification of high-risk patient population can help device new strategies for improved ED care with reduced ED utilization.A decision tree based model with discriminant Electronic Medical Record (EMR features was developed and validated, estimating patient ED 30 day revisit risk. A retrospective cohort of 293,461 ED encounters from HealthInfoNet (HIN, Maine's Health Information Exchange (HIE, between January 1, 2012 and December 31, 2012, was assembled with the associated patients' demographic information and one-year clinical histories before the discharge date as the inputs. To validate, a prospective cohort of 193,886 encounters between January 1, 2013 and June 30, 2013 was constructed. The c-statistics for the retrospective and prospective predictions were 0.710 and 0.704 respectively. Clinical resource utilization, including ED use, was analyzed as a function of the ED risk score. Cluster analysis of high-risk patients identified discrete sub-populations with distinctive demographic, clinical and resource utilization patterns.Our ED 30-day revisit model was prospectively validated on the Maine State HIN secure statewide data system. Future integration of our ED predictive analytics into the ED care work flow may lead to increased opportunities for targeted care intervention to reduce ED resource burden and overall healthcare expense, and improve outcomes.

  11. Radio frequency discharge with dust particles

    Chutov, Y. I.; W. J. Goedheer,; Kravchenko, O. Y.; Zuz, V. M.; Yan, M.; Martins, R.; Ferreira, I.; Fortunato, E.; Kroesen, G.

    2000-01-01

    A 1D PIC/MCC method has been developed for computer simulations of low-pressure RF discharges with dust particles using the method for dust-free discharges. A RF discharge in argon with dust particles distributed uniformly in the interelectrode gap is simulated at parameters providing a possibility

  12. Theoretical provisions for the discharge at TJ-1 (Preliminary study); Previsiones teoricas para la descarga del TJ-1 (Estudio preliminar)

    Guasp, J

    1981-07-01

    Using the transport code PLASMATOR a numerical study about the TJ-1 discharge (a Tokamak close to be installed at JEN) has been made, observing the behaviour under huge variations on the transport coefficients as well as on density and current. Noteworthy a scaling law of the kind {tau}{sub E}{approx}n{sub {theta}} has been contested at not too high density, The model insensibility upon the initial values has been confirmed and the effects of variations on the recycling coefficient and the rate rise of current studied too. Finally comparisons with alternative models have been accomplished. (Author) 29 refs.

  13. Gas Temperature Measurement in a Glow Discharge Plasma

    Sloneker, Kenneth; Podder, Nirmol; McCurdy, William E.; Shi, Shi

    2009-10-01

    In this study a relatively inexpensive quartz protected thermocouple is used to measure the gas temperature in the positive column of a glow discharge plasma. For simplicity a K-type thermocouple is used to interpret the gas temperature from the sensor voltage at pressures from 0.5 Torr to 15 Torr and discharge currents from 5 mA to 120 mA. Gas temperature is investigated as a function of the gas pressure at fixed discharge currents and as a function of discharge current at fixed gas pressures in three different gas species (Ar, N2, and He). An infinite cylinder model is used to compute the average gas temperature of the discharge from joule heating and gas thermal conductivity. The model and measurement data agree within 1% to 10% depending on plasma parameters. Data for all three gases have a similar quasi-linear increasing error as compared to the model.

  14. Costs and outcomes associated with alternative discharge strategies following joint replacement surgery: analysis of an observational study using a propensity score.

    Coyte, P C; Young, W; Croxford, R

    2000-11-01

    We estimated the impact of alternative discharge strategies, following joint replacement (JR) surgery, on acute care readmission rates and the total cost of a continuum of care. Following surgery, patients were discharged to one of four destinations. Propensity scores were used to adjust costs and outcomes for potential bias in the assignment of discharge destinations. We demonstrated that the use of rehabilitation hospitals may lower readmission rates, but at a prohibitive incremental cost of each saved readmission, that patients discharged with home care had longer acute care stays than other patients, that the provision of home care services increased health system costs, and that acute care readmission rates were greatest among patients discharged with home care. Our study should be seen as one important stepping stone towards a full economic evaluation of the continuum of care for patients.

  15. Deterministic dynamics of plasma focus discharges

    Gratton, J.; Alabraba, M.A.; Warmate, A.G.; Giudice, G.

    1992-04-01

    The performance (neutron yield, X-ray production, etc.) of plasma focus discharges fluctuates strongly in series performed with fixed experimental conditions. Previous work suggests that these fluctuations are due to a deterministic ''internal'' dynamics involving degrees of freedom not controlled by the operator, possibly related to adsorption and desorption of impurities from the electrodes. According to these dynamics the yield of a discharge depends on the outcome of the previous ones. We study 8 series of discharges in three different facilities, with various electrode materials and operating conditions. More evidence of a deterministic internal dynamics is found. The fluctuation pattern depends on the electrode materials and other characteristics of the experiment. A heuristic mathematical model that describes adsorption and desorption of impurities from the electrodes and their consequences on the yield is presented. The model predicts steady yield or periodic and chaotic fluctuations, depending on parameters related to the experimental conditions. (author). 27 refs, 7 figs, 4 tabs

  16. Dynamic Parameter Identification of Subject-Specific Body Segment Parameters Using Robotics Formalism: Case Study Head Complex.

    Díaz-Rodríguez, Miguel; Valera, Angel; Page, Alvaro; Besa, Antonio; Mata, Vicente

    2016-05-01

    Accurate knowledge of body segment inertia parameters (BSIP) improves the assessment of dynamic analysis based on biomechanical models, which is of paramount importance in fields such as sport activities or impact crash test. Early approaches for BSIP identification rely on the experiments conducted on cadavers or through imaging techniques conducted on living subjects. Recent approaches for BSIP identification rely on inverse dynamic modeling. However, most of the approaches are focused on the entire body, and verification of BSIP for dynamic analysis for distal segment or chain of segments, which has proven to be of significant importance in impact test studies, is rarely established. Previous studies have suggested that BSIP should be obtained by using subject-specific identification techniques. To this end, our paper develops a novel approach for estimating subject-specific BSIP based on static and dynamics identification models (SIM, DIM). We test the validity of SIM and DIM by comparing the results using parameters obtained from a regression model proposed by De Leva (1996, "Adjustments to Zatsiorsky-Seluyanov's Segment Inertia Parameters," J. Biomech., 29(9), pp. 1223-1230). Both SIM and DIM are developed considering robotics formalism. First, the static model allows the mass and center of gravity (COG) to be estimated. Second, the results from the static model are included in the dynamics equation allowing us to estimate the moment of inertia (MOI). As a case study, we applied the approach to evaluate the dynamics modeling of the head complex. Findings provide some insight into the validity not only of the proposed method but also of the application proposed by De Leva (1996, "Adjustments to Zatsiorsky-Seluyanov's Segment Inertia Parameters," J. Biomech., 29(9), pp. 1223-1230) for dynamic modeling of body segments.

  17. Hysterectomy - vaginal - discharge

    Vaginal hysterectomy - discharge; Laparoscopically assisted vaginal hysterectomy - discharge; LAVH - discharge ... you were in the hospital, you had a vaginal hysterectomy. Your surgeon made a cut in your ...

  18. Improved communication in post-ICU care by improving writing of ICU discharge letters: a longitudinal before-after study

    Medlock, Stephanie; Eslami, Saeid; Askari, Marjan; van Lieshout, Erik Jan; Dongelmans, Dave A.; Abu-Hanna, Ameen

    2011-01-01

    The discharge letter is the primary means of communication at patient discharge, yet discharge letters are often not completed on time. A multifaceted intervention was performed to improve communication in patient hand-off from the intensive care unit (ICU) to the wards by improving the timeliness

  19. Improved communication in post-ICU care by improving writing of ICU discharge letters: a longitudinal before-after study

    Medlock, S.; Eslami, S.; Askari, M.; van Lieshout, E.J.; Dongelmans, D.A.; Abu-Hanna, A.

    2011-01-01

    Background: The discharge letter is the primary means of communication at patient discharge, yet discharge letters are often not completed on time. A multifaceted intervention was performed to improve communication in patient hand-off from the intensive care unit (ICU) to the wards by improving the

  20. The effect of an auxiliary discharge on anode sheath potentials in a transverse discharge

    Foster, J.E.; Gallimore, A.D.

    1997-01-01

    A novel scheme that employs the use of an auxiliary discharge has been shown to reduce markedly anode sheath potentials in a transverse discharge. An 8.8 A low-pressure argon discharge in the presence of a transverse magnetic field was used as the plasma source in this study. In such discharges, the transverse flux that is collected by the anode is severely limited due to marked reductions in the transverse diffusion coefficient. Findings of this study indicate that the local electron number density and the transverse flux increase when the auxiliary discharge is operated. Changes in these parameters are reflected in the measured anode sheath voltage. Anode sheath potentials, estimated by using Langmuir probes, were shown to be reduced by over 33% when the auxiliary discharge is operated. These reductions in anode sheath potentials translated into significant reductions in anode power flux as measured using water calorimeter techniques. The reductions in anode power flux also correlate well with changes in the electron transverse flux. Finally, techniques implementing these positive effects in real plasma accelerators are discussed. copyright 1997 American Institute of Physics