WorldWideScience

Sample records for direct x-ray holographic

  1. A New Method of X-Ray Holographic Tomography

    Institute of Scientific and Technical Information of China (English)

    谢红兰; 陈建文; 高鸿奕; 陆培祥; 徐至展

    2002-01-01

    A new method of x-ray holographic tomography, called pre-amplified x-ray holographic tomography, is proposed to develop an x-ray three-dimensional microscopic imaging technique. In this method, the key component is a micro zone plate taken as an imaging element like an optic lens in x-ray field. Some advantages of the method are shown by a numerical example. The method may make it possible to obtain x-ray microscopic imaging of biological specimens at high resolution in three dimensions.

  2. Progress in high-resolution x-ray holographic microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, C.; Kirz, J.; Howells, M.; McQuaid, K.; Rothman, S.; Feder, R.; Sayre, D.

    1987-07-01

    Among the various types of x-ray microscopes that have been demonstrated, the holographic microscope has had the largest gap between promise and performance. The difficulties of fabricating x-ray optical elements have led some to view holography as the most attractive method for obtaining the ultimate in high resolution x-ray micrographs; however, we know of no investigations prior to 1987 that clearly demonstrated submicron resolution in reconstructed images. Previous efforts suffered from problems such as limited resolution and dynamic range in the recording media, low coherent x-ray flux, and aberrations and diffraction limits in visible light reconstruction. We have addressed the recording limitations through the use of an undulator x-ray source and high-resolution photoresist recording media. For improved results in the readout and reconstruction steps, we have employed metal shadowing and transmission electron microscopy, along with numerical reconstruction techniques. We believe that this approach will allow holography to emerge as a practical method of high-resolution x-ray microscopy. 30 refs., 4 figs.

  3. X-ray holographic microscopy: Improved images of zymogen granules

    Energy Technology Data Exchange (ETDEWEB)

    Jacobsen, C.; Howells, M.; Kirz, J.; McQuaid, K.; Rothman, S.

    1988-10-01

    Soft x-ray holography has long been considered as a technique for x-ray microscopy. It has been only recently, however, that sub-micron resolution has been obtained in x-ray holography. This paper will concentrate on recent progress we have made in obtaining reconstructed images of improved quality. 15 refs., 6 figs.

  4. Direct-write X-ray lithography using a hard X-ray Fresnel zone plate.

    Science.gov (United States)

    Lee, Su Yong; Noh, Do Young; Lee, Hae Cheol; Yu, Chung-Jong; Hwu, Yeukuang; Kang, Hyon Chol

    2015-05-01

    Results are reported of direct-write X-ray lithography using a hard X-ray beam focused by a Fresnel zone plate with an outermost zone width of 40 nm. An X-ray beam at 7.5 keV focused to a nano-spot was employed to write arbitrary patterns on a photoresist thin film with a resolution better than 25 nm. The resulting pattern dimension depended significantly on the kind of underlying substrate, which was attributed to the lateral spread of electrons generated during X-ray irradiation. The proximity effect originated from the diffuse scattering near the focus and electron blur was also observed, which led to an increase in pattern dimension. Since focusing hard X-rays to below a 10 nm spot is currently available, the direct-write hard X-ray lithography developed in this work has the potential to be a promising future lithographic method.

  5. Frontiers in x-ray components for high-resolution spectroscopy and imaging laminar type varied-line-spacing holographic gratings for soft x-ray

    CERN Document Server

    Sano, K

    2003-01-01

    Laminar-type varied-line-spacing gratings have been widely used for soft x-ray monochromator recently because of the features of low stray lights and higher order lights. We have developed and advanced holographic recording and an ion-beam etching methods for the laminar type varied-line spacing gratings. This report describes a short review of the soft x-ray spectrometers using varied-line-spacing gratings, the fabrication process of the laminar-type holographic gratings, and the performance of the flat field spectrographs equipped with the laminar type varied-line spacing gratings comparing with the mechanically ruled replica gratings. It is concluded that, for the sake of the advanced design and fabrication processes and excellent spectroscopic performance, laminar-type holographic gratings will be widely used for soft x-ray spectrometers for various purposes in the near future. (author)

  6. Silicon avalanche photodiodes for direct detection of X-rays.

    Science.gov (United States)

    Baron, Alfred Q R; Kishimoto, Shunji; Morse, John; Rigal, Jean Marie

    2006-03-01

    Silicon avalanche photodiodes (APDs) are discussed as fast X-ray detectors for synchrotron radiation. The emphasis is on ;direct' detection, where the X-ray is absorbed within the silicon APD itself, and, therefore, on use with medium-energy X-rays, <30 keV. The impact of APD structure on device performance is examined, and representative data from many different commercial devices are presented. Specific areas discussed include signal shapes, high-rate behavior, time resolution and pulse-height response. Data from several APD arrays are also presented, as is a detailed description of an integrated package system. Tables are included comparing commercially available devices, including arrays.

  7. Holographic methods in X-ray crystallography. Pt. 4. A fast algorithm and its application to macromolecular crystallography

    Energy Technology Data Exchange (ETDEWEB)

    Somoza, J.R. [California Univ., Berkeley (United States). Dept. of Chemistry]|[Lawrence Berkeley Lab., CA (United States); Szoeke, H. [Lawrence Livermore National Lab., CA (United States); Goodman, D.M. [Lawrence Livermore National Lab., CA (United States); Beran, P. [Lawrence Livermore National Lab., CA (United States); Truckses, D. [Wisconsin Univ., Madison, WI (United States). Dept. of Biochemistry; Kim, S.H. [California Univ., Berkeley (United States). Dept. of Chemistry]|[Lawrence Berkeley Lab., CA (United States); Szoeke, A. [Lawrence Livermore National Lab., CA (United States)

    1995-09-01

    The holographic method makes use of partially modeled electron density and experimentally measured structure-factor amplitudes to recover electron density corresponding to the unmodeled part of a crystal structure. This paper describes a fast algorithm that makes it possible to apply the holographic method to sizable crystallographic problems. The algorithm uses positivity constraints on the electron density and can incorporate a `target` electron density, making it similar to solvent flattening. The potential for applying the holographic method to macromolecular X-ray crystallography is assessed using both synthetic and experimental data. (orig.).

  8. High resolution x-ray lensless imaging by differential holographic encoding

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, D.; Guizar-Sicairos, M.; Wu, B.; Scherz, A.; Acremann, Y.; Tylisczcak, T.; Fischer, P.; Friedenberger, N.; Ollefs, K.; Farle, M.; Fienup, J. R.; Stohr, J.

    2009-11-02

    X-ray free electron lasers (X-FEL{sub s}) will soon offer femtosecond pulses of laterally coherent x-rays with sufficient intensity to record single-shot coherent scattering patterns for nanoscale imaging. Pulse trains created by splitand-delay techniques even open the door for cinematography on unprecedented nanometer length and femtosecond time scales. A key to real space ultrafast motion pictures is fast and reliable inversion of the recorded reciprocal space scattering patterns. Here we for the first time demonstrate in the x-ray regime the power of a novel technique for lensless high resolution imaging, previously suggested by Guizar-Sicairos and Fienup termed holography with extended reference by autocorrelation linear differential operation, HERALD0. We have achieved superior resolution over conventional x-ray Fourier transform holography (FTH) without sacrifices in SNR or significant increase in algorithmic complexity. By combining images obtained from individual sharp features on an extended reference, we further show that the resolution can be even extended beyond the reference fabrication limits. Direct comparison to iterative phase retrieval image reconstruction and images recorded with stateof- the-art zone plate microscopes is presented. Our results demonstrate the power of HERALDO as a favorable candidate for robust inversion of single-shot coherent scattering patterns.

  9. High-Resolution X-Ray Lensless Imaging by Differential Holographic Encoding

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Diling [Stanford Univ., CA (United States). Dept. of Applied Physics; SLAC National Accelerator Lab., Menlo Park, CA (United States). Stanford Inst. for Material and Energy Science; Guizar-Sicairos, Manuel [Univ. of Rochester, NY (United States). Inst. of Optics; Wu, Benny [Stanford Univ., CA (United States). Dept. of Applied Physics; SLAC National Accelerator Lab., Menlo Park, CA (United States). Stanford Inst. for Material and Energy Science; Scherz, Andreas [SLAC National Accelerator Lab., Menlo Park, CA (United States). Stanford Inst. for Material and Energy Science; Acremann, Yves [SLAC National Accelerator Lab., Menlo Park, CA (United States). Photon Ultrafast Laser Science and Engineering Inst. (PULSE); Tyliszczak, Tolek [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Advanced Light Source (ALS); Fischer, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Center for X-ray Optics; Friedenberger, Nina [Universitat Duisburg-Essen (Germany). Dept. of Physics and Center for Nanointegration Duisburg-Essen (CeNIDE); Ollefs, Katharina [Universitat Duisburg-Essen (Germany). Dept. of Physics and Center for Nanointegration Duisburg-Essen (CeNIDE); Farle, Michael [Universitat Duisburg-Essen (Germany). Dept. of Physics and Center for Nanointegration Duisburg-Essen (CeNIDE); Fienup, James R. [Univ. of Rochester, NY (United States). Inst. of Optics; Stöhr, Joachim [SLAC National Accelerator Lab., Menlo Park, CA (United States). Linac Coherent Light Source (LCLS)

    2010-07-01

    X-ray free electron lasers (X-FELs) will soon offer femtosecond pulses of laterally coherent x-rays with sufficient intensity to record single-shot coherent scattering patterns for nanoscale imaging. Pulse trains created by split and- delay techniques even open the door for cinematography on unprecedented nanometer length and femtosecond time scales. A key to real space ultrafast motion pictures is fast and reliable inversion of the recorded reciprocal space scattering patterns. Here we for the first time demonstrate in the x-ray regime the power of a novel technique for lensless high resolution imaging, previously suggested by Guizar-Sicairos and Fienup termed holography with extended reference by autocorrelation linear differential operation, HERALD0. We have achieved superior resolution over conventional x-ray Fourier transform holography (FTH) without sacrifices in SNR or significant increase in algorithmic complexity. By combining images obtained from individual sharp features on an extended reference, we further show that the resolution can be even extended beyond the reference fabrication limits. Direct comparison to iterative phase retrieval image reconstruction and images recorded with state of-the-art zone plate microscopes is presented. Our results demonstrate the power of HERALDO as a favorable candidate for robust inversion of single-shot coherent scattering patterns.

  10. Hard X-ray-induced optical luminescence via biomolecule-directed metal clusters.

    Science.gov (United States)

    Osakada, Yasuko; Pratx, Guillem; Sun, Conroy; Sakamoto, Masanori; Ahmad, Moiz; Volotskova, Olga; Ong, Qunxiang; Teranishi, Toshiharu; Harada, Yoshie; Xing, Lei; Cui, Bianxiao

    2014-04-07

    Here, we demonstrate that biomolecule-directed metal clusters are applicable in the study of hard X-ray excited optical luminescence, promising a new direction in the development of novel X-ray-activated imaging probes.

  11. Direct surface magnetometry with photoemission magnetic x-ray dichroism

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, J.G.; Goodman, K.W. [Lawrence Berkeley National Lab., CA (United States); Schumann, F.O. [Pennsylvania State Univ., University Park, PA (United States)] [and others

    1997-04-01

    Element specific surface magnetometry remains a central goal of synchrotron radiation based studies of nanomagnetic structures. One appealing possibility is the combination of x-ray absorption dichroism measurements and the theoretical framework provided by the {open_quotes}sum rules.{close_quotes} Unfortunately, sum rule analysis are hampered by several limitations including delocalization of the final state, multi-electronic phenomena and the presence of surface dipoles. An alternative experiment, Magnetic X-Ray Dichroism in Photoelectron Spectroscopy, holds out promise based upon its elemental specificity, surface sensitivity and high resolution. Computational simulations by Tamura et al. demonstrated the relationship between exchange and spin orbit splittings and experimental data of linear and circular dichroisms. Now the authors have developed an analytical framework which allows for the direct extraction of core level exchange splittings from circular and linear dichroic photoemission data. By extending a model initially proposed by Venus, it is possible to show a linear relation between normalized dichroism peaks in the experimental data and the underlying exchange splitting. Since it is reasonable to expect that exchange splittings and magnetic moments track together, this measurement thus becomes a powerful new tool for direct surface magnetometry, without recourse to time consuming and difficult spectral simulations. The theoretical derivation will be supported by high resolution linear and circular dichroism data collected at the Spectromicroscopy Facility of the Advanced Light Source.

  12. A final report to the Laboratory Directed Research and Development committee on Project 93-ERP-075: ``X-ray laser propagation and coherence: Diagnosing fast-evolving, high-density laser plasmas using X-ray lasers``

    Energy Technology Data Exchange (ETDEWEB)

    Wan, A.S.; Cauble, R.; Da Silva, L.B.; Libby, S.B.; Moreno, J.C.

    1996-02-01

    This report summarizes the major accomplishments of this three-year Laboratory Directed Research and Development (LDRD) Exploratory Research Project (ERP) entitled ``X-ray Laser Propagation and Coherence: Diagnosing Fast-evolving, High-density Laser Plasmas Using X-ray Lasers,`` tracking code 93-ERP-075. The most significant accomplishment of this project is the demonstration of a new laser plasma diagnostic: a soft x-ray Mach-Zehnder interferometer using a neonlike yttrium x-ray laser at 155 {angstrom} as the probe source. Detailed comparisons of absolute two-dimensional electron density profiles obtained from soft x-ray laser interferograms and profiles obtained from radiation hydrodynamics codes, such as LASNEX, will allow us to validate and benchmark complex numerical models used to study the physics of laser-plasma interactions. Thus the development of soft x-ray interferometry technique provides a mechanism to probe the deficiencies of the numerical models and is an important tool for, the high-energy density physics and science-based stockpile stewardship programs. The authors have used the soft x-ray interferometer to study a number of high-density, fast evolving, laser-produced plasmas, such as the dynamics of exploding foils and colliding plasmas. They are pursuing the application of the soft x-ray interferometer to study ICF-relevant plasmas, such as capsules and hohlraums, on the Nova 10-beam facility. They have also studied the development of enhanced-coherence, shorter-pulse-duration, and high-brightness x-ray lasers. The utilization of improved x-ray laser sources can ultimately enable them to obtain three-dimensional holographic images of laser-produced plasmas.

  13. Direct detection of x-rays for protein crystallography employing a thick, large area CCD

    Science.gov (United States)

    Atac, Muzaffer; McKay, Timothy

    1999-01-01

    An apparatus and method for directly determining the crystalline structure of a protein crystal. The crystal is irradiated by a finely collimated x-ray beam. The interaction of the x-ray beam with the crystal produces scattered x-rays. These scattered x-rays are detected by means of a large area, thick CCD which is capable of measuring a significant number of scattered x-rays which impact its surface. The CCD is capable of detecting the position of impact of the scattered x-ray on the surface of the CCD and the quantity of scattered x-rays which impact the same cell or pixel. This data is then processed in real-time and the processed data is outputted to produce a image of the structure of the crystal. If this crystal is a protein the molecular structure of the protein can be determined from the data received.

  14. Soft X-ray Holographic Microscopy with Sub-micrometer Resolution

    Institute of Scientific and Technical Information of China (English)

    JIANG Shiping; GAO Hongyi; ZHANG Yuxuan; ZHANG Xinyi1CHEN Min; Jianwen; XU Zhizhan

    2001-01-01

    Gabor X-ray in-line holograms are recorded with a photoresist at Hefei National Synchrotron Radiation Laboratory. An Atomic Force Microscope (AFM) is used to read the X-ray holograms of minute granules recorded on photoresist PMMA. Digitized hologram is reconstructed by numerical method. The granules with a size less than 0.3 μm can be resolved in the reconstructed image. So the eatimated resolution reaches the level of suibmicrometer.

  15. Development of an X-ray fluorescence holographic measurement system for protein crystals

    Science.gov (United States)

    Sato-Tomita, Ayana; Shibayama, Naoya; Happo, Naohisa; Kimura, Koji; Okabe, Takahiro; Matsushita, Tomohiro; Park, Sam-Yong; Sasaki, Yuji C.; Hayashi, Kouichi

    2016-06-01

    Experimental procedure and setup for obtaining X-ray fluorescence hologram of crystalline metalloprotein samples are described. Human hemoglobin, an α2β2 tetrameric metalloprotein containing the Fe(II) heme active-site in each chain, was chosen for this study because of its wealth of crystallographic data. A cold gas flow system was introduced to reduce X-ray radiation damage of protein crystals that are usually fragile and susceptible to damage. A χ-stage was installed to rotate the sample while avoiding intersection between the X-ray beam and the sample loop or holder, which is needed for supporting fragile protein crystals. Huge hemoglobin crystals (with a maximum size of 8 × 6 × 3 mm3) were prepared and used to keep the footprint of the incident X-ray beam smaller than the sample size during the entire course of the measurement with the incident angle of 0°-70°. Under these experimental and data acquisition conditions, we achieved the first observation of the X-ray fluorescence hologram pattern from the protein crystals with minimal radiation damage, opening up a new and potential method for investigating the stereochemistry of the metal active-sites in biomacromolecules.

  16. Development of an X-ray fluorescence holographic measurement system for protein crystals

    Energy Technology Data Exchange (ETDEWEB)

    Sato-Tomita, Ayana, E-mail: ayana.sato@jichi.ac.jp, E-mail: shibayam@jichi.ac.jp, E-mail: hayashi.koichi@nitech.ac.jp; Shibayama, Naoya, E-mail: ayana.sato@jichi.ac.jp, E-mail: shibayam@jichi.ac.jp, E-mail: hayashi.koichi@nitech.ac.jp; Okabe, Takahiro [Division of Biophysics, Department of Physiology, Jichi Medical University, Yakushiji, Shimotsuke 329-0498 (Japan); Happo, Naohisa [Department of Computer and Network Engineering, Graduate School of Information Sciences, Hiroshima City University, Asa-Minami-Ku, Hiroshima 731-3194 (Japan); Kimura, Koji [Department of Physical Science and Engineering, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555 (Japan); Matsushita, Tomohiro [Japan Synchrotron Radiation Research Institute (JASRI), SPring-8, Sayo, Hyogo 679-5198 (Japan); Park, Sam-Yong [Drug Design Laboratory, Department of Medical Life Science, Yokohama City University, Suehiro, Tsurumi, Yokohama 230-0045 (Japan); Sasaki, Yuji C. [Department of Advanced Material Science, Graduate School of Frontier Science, The University of Tokyo, Kashiwanoha, Kashiwa 277-8561 (Japan); Hayashi, Kouichi, E-mail: ayana.sato@jichi.ac.jp, E-mail: shibayam@jichi.ac.jp, E-mail: hayashi.koichi@nitech.ac.jp [Department of Physical Science and Engineering, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555 (Japan); Frontier Research Institute for Materials Science, Nagoya Institute of Technology, Gokiso, Showa, Nagoya 466-8555 (Japan)

    2016-06-15

    Experimental procedure and setup for obtaining X-ray fluorescence hologram of crystalline metalloprotein samples are described. Human hemoglobin, an α{sub 2}β{sub 2} tetrameric metalloprotein containing the Fe(II) heme active-site in each chain, was chosen for this study because of its wealth of crystallographic data. A cold gas flow system was introduced to reduce X-ray radiation damage of protein crystals that are usually fragile and susceptible to damage. A χ-stage was installed to rotate the sample while avoiding intersection between the X-ray beam and the sample loop or holder, which is needed for supporting fragile protein crystals. Huge hemoglobin crystals (with a maximum size of 8 × 6 × 3 mm{sup 3}) were prepared and used to keep the footprint of the incident X-ray beam smaller than the sample size during the entire course of the measurement with the incident angle of 0°-70°. Under these experimental and data acquisition conditions, we achieved the first observation of the X-ray fluorescence hologram pattern from the protein crystals with minimal radiation damage, opening up a new and potential method for investigating the stereochemistry of the metal active-sites in biomacromolecules.

  17. X-ray diffraction study of directionally grown perylene crystallites

    DEFF Research Database (Denmark)

    Breiby, Dag W.; Lemke, H. T.; Hammershøj, P.

    2008-01-01

    Using grazing incidence X-ray diffraction, perylene crystallites grown on thin highly oriented poly(tetrafluoroethylene) (PTFE) films on silicon substrates have been investigated. All the perylene crystallites are found to orient with the ab plane of the monoclinic unit cell parallel to the subst......Using grazing incidence X-ray diffraction, perylene crystallites grown on thin highly oriented poly(tetrafluoroethylene) (PTFE) films on silicon substrates have been investigated. All the perylene crystallites are found to orient with the ab plane of the monoclinic unit cell parallel...... to the substrate. The scattering data is interpreted as a trimodal texture of oriented perylene crystallites, induced by interactions between the perylene molecules and the oriented PTFE substrate. Three families of biaxial orientations are seen, with the axes (h = 1, 2, or 3) parallel to the PTFE alignment......, all having the ab-plane parallel to the substrate. About 92% of the scattered intensity corresponds to a population with highly parallel to (PTFE)....

  18. 3D contrast-enhanced MR portography and direct X-ray portography: a correlation study

    Energy Technology Data Exchange (ETDEWEB)

    Lin Jiang; Zhou Kangrong; Chen Zuang; Wang Jianhua; Yan Ziping [Department of Radiology, ZhongShan Hospital, Fudan University, Shanghai (China); Wang Yixiang J. [Department of Radiology, Rui Jin Hospital, Shanghai Second Medical Univeristy, Shanghai (China)

    2003-06-01

    Our objective was to compare 3D contrast-enhanced MR portography (3D CE MRP) on a 1.5-T MR imager with direct X-ray portography. Twenty-six consecutive patients underwent 3D CE MRP with in-plane resolution of 1.4 or 1.8 mm, and direct X-ray portography. The findings of these two methods were evaluated and compared. The main portal vein (PV), right PV with its anterior and posterior segmental branches, and left PV including its sagittal segment were shown clearly without diagnostic problem in all cases on MRP. The main PV appearance was accordant with MRP and X-ray. For intrahepatic PVs, the results agreed in 21 patients but disagreed in 5 patients. In 1 patient with a huge tumor in right liver, the right posterior PV was classified as occluded at MRP, but diffusely narrowed at X-ray. The findings of left intrahepatic PV were discordant in 3 patients with hepatocelluar carcinoma in the left lobe. The MRP demonstrated complete occlusion of the left PVs, whereas X-ray showed proximal narrowing and distal occlusion. In another patient with hepatocelluar carcinoma, a small non-occlusive thrombus involving the sagittal segment of the left PV was seen on MRP but not on X-ray. With demonstration of varices and portosystemic shunts, MRP showed results similar to those of X-ray, except one recanalized para-umbilical vein was excluded from the field of view at MRP due to the patient's limited ability of breathholding. The 3D CE MRP correlated well with direct X-ray portography in most cases, it was limited in distinguishing narrowing of an intrahepatic PV from occlusion, but it showed advantage in demonstrating small thrombus within PV. (orig.)

  19. Direct observation of unstained wet biological samples by scanning-electron generation X-ray microscopy.

    Science.gov (United States)

    Ogura, Toshihiko

    2010-01-01

    Analytical tools of nanometre-scale resolution are indispensable in the fields of biology, physics and chemistry. One suitable tool, the soft X-ray microscope, provides high spatial resolution of visible light for wet specimens. For biological specimens, X-rays of water-window wavelength between carbon (284 eV; 4.3 nm) and oxygen (540 eV; 2.3 nm) absorption edges provide high-contrast imaging of biological samples in water. Among types of X-ray microscope, the transmission X-ray microscope using a synchrotron radiation source with diffractive zone plates offers the highest spatial resolution, approaching 15-10nm. However, even higher resolution is required to measure proteins and protein complexes in biological specimens; therefore, a new type of X-ray microscope with higher resolution that uses a simple light source is desirable. Here we report a novel scanning-electron generation X-ray microscope (SGXM) that demonstrates direct imaging of unstained wet biological specimens. We deposited wet yeasts in the space between two silicon nitride (Si(3)N(4)) films. A scanning electron beam of accelerating voltage 5 keV and current 1.6 nA irradiates the titanium (Ti)-coated Si(3)N(4) film, and the soft X-ray signal from it is detected by an X-ray photodiode (PD) placed below the sample. The SGXM can theoretically achieve better than 5 nm resolution. Our method can be utilized easily for various wet biological samples of bacteria, viruses, and protein complexes.

  20. Dense Heavy Metal Aerosol Monitoring by Direct X-Ray Fluorescence

    Science.gov (United States)

    1989-06-01

    TECHNICAL REPORT BRL-TR-3003 BRL 0 sDENSE HEAVY METAL AEROSOL MONITORING BY DIRECT X-RAY FLUORESCENCE I GEORGE M. THOMSON flgDTIC ELF% CTE b JUN 16...21005-5066 /F 6261A jIN8 1001I 11. TITLE (-’mi- Sawt Cauif&aan)II DENSE HEAVY METAL AEROSOL MONITORMN BY DIRECT X-RAY FLUORESCENCE 12. PERSONAL AUTHOR(S...Before proceeding, a definition of the term "dense, heavy - metal aerosol" is in order. For present purposes, it is an aerosol in which the suspended

  1. Development of a Direct Fabrication Technique for Full-Shell X-Ray Optics

    Science.gov (United States)

    Gubarev, M.; Kolodziejczak, J. K.; Griffith, C.; Roche, J.; Smith, W. S.; Kester, T.; Atkins, C.; Arnold, W.; Ramsey, B.

    2016-01-01

    Future astrophysical missions will require fabrication technology capable of producing high angular resolution x-ray optics. A full-shell direct fabrication approach using modern robotic polishing machines has the potential for producing high resolution, light-weight and affordable x-ray mirrors that can be nested to produce large collecting area. This approach to mirror fabrication, based on the use of the metal substrates coated with nickel phosphorous alloy, is being pursued at MSFC. The design of the polishing fixtures for the direct fabrication, the surface figure metrology techniques used and the results of the polishing experiments are presented.

  2. Transfer Functions for Direct Temporal Structure Measurement of Femtosecond Soft X-Ray

    Institute of Scientific and Technical Information of China (English)

    GE Yu-Cheng

    2005-01-01

    @@ Under cross correlation between linearly polarized short duration laser and narrow bandwidth soft x-ray, the temporal structure of femtosecond soft x-ray can be directly reconstructed via the presented transfer functions from energy derivative of the excited photoelectron energy spectrum measured in the direction of or perpendicular to the laser polarization. The method has a broader temporal measurement range. The energy resolution of a photoelectron spectrometer and the size of energy bin are two important parameters for both measurement and calculation. The methods can be used for ultra-fast measurements and pump-probe detections on the femtosecond time scale.

  3. Directly-deposited blocking filters for high-performance silicon x-ray detectors

    Science.gov (United States)

    Bautz, M.; Kissel, S.; Masterson, R.; Ryu, K.; Suntharalingam, V.

    2016-07-01

    Silicon X-ray detectors often require blocking filters to mitigate noise and out-of-band signal from UV and visible backgrounds. Such filters must be thin to minimize X-ray absorption, so direct deposition of filter material on the detector entrance surface is an attractive approach to fabrication of robust filters. On the other hand, the soft (E X-ray spectral resolution of the detector is sensitive to the charge collection efficiency in the immediate vicinity of its entrance surface, so it is important that any filter layer is deposited without disturbing the electric field distribution there. We have successfully deposited aluminum blocking filters, ranging in thickness from 70 to 220nm, on back-illuminated CCD X-ray detectors passivated by means of molecular beam epitaxy. Here we report measurements showing that directly deposited filters have little or no effect on soft X-ray spectral resolution. We also find that in applications requiring very large optical density (> OD 6) care must be taken to prevent light from entering the sides and mounting surfaces of the detector. Our methods have been used to deposit filters on the detectors of the REXIS instrument scheduled to fly on OSIRIS-ReX later this year.

  4. DIRECT MEASUREMENT OF THE X-RAY TIME-DELAY TRANSFER FUNCTION IN ACTIVE GALACTIC NUCLEI

    Energy Technology Data Exchange (ETDEWEB)

    Legg, E.; Miller, L. [Department of Physics, Oxford University, Keble Road, Oxford OX1 3RH (United Kingdom); Turner, T. J.; Giustini, M.; Reeves, J. N. [Department of Physics, University of Maryland Baltimore County, Baltimore, MD 21250 (United States); Kraemer, S. B. [Institute for Astrophysics and Computational Sciences, Department of Physics, The Catholic University of America, Washington, DC 20064 (United States)

    2012-11-20

    The origin of the observed time lags, in nearby active galactic nuclei (AGNs), between hard and soft X-ray photons is investigated using new XMM-Newton data for the narrow-line Seyfert I galaxy Ark 564 and existing data for 1H 0707-495 and NGC 4051. These AGNs have highly variable X-ray light curves that contain frequent, high peaks of emission. The averaged light curve of the peaks is directly measured from the time series, and it is shown that (1) peaks occur at the same time, within the measurement uncertainties, at all X-ray energies, and (2) there exists a substantial tail of excess emission at hard X-ray energies, which is delayed with respect to the time of the main peak, and is particularly prominent in Ark 564. Observation (1) rules out that the observed lags are caused by Comptonization time delays and disfavors a simple model of propagating fluctuations on the accretion disk. Observation (2) is consistent with time lags caused by Compton-scattering reverberation from material a few thousand light-seconds from the primary X-ray source. The power spectral density and the frequency-dependent phase lags of the peak light curves are consistent with those of the full time series. There is evidence for non-stationarity in the Ark 564 time series in both the Fourier and peaks analyses. A sharp 'negative' lag (variations at hard photon energies lead soft photon energies) observed in Ark 564 appears to be generated by the shape of the hard-band transfer function and does not arise from soft-band reflection of X-rays. These results reinforce the evidence for the existence of X-ray reverberation in type I AGN, which requires that these AGNs are significantly affected by scattering from circumnuclear material a few tens or hundreds of gravitational radii in extent.

  5. Chandra Observation of an X-ray Flare at Saturn: Evidence for Direct Solar Control on Saturn's Disk X-ray Emissions

    CERN Document Server

    Bhardwaj, A; Elsner, R F; Ford, P G; Gladstone, G R; Bhardwaj, Anil; Cravens, Thomas E.; Elsner, Ronald F.; Ford, Peter G.

    2005-01-01

    Saturn was observed by Chandra ACIS-S on 20 and 26-27 January 2004 for one full Saturn rotation (10.7 hr) at each epoch. We report here the first observation of an X-ray flare from Saturn's non-auroral (low-latitude) disk, which is seen in direct response to an M6-class flare emanating from a sunspot that was clearly visible from both Saturn and Earth. Saturn's disk X-ray emissions are found to be variable on time scales of hours to weeks to months, and correlated with solar F10.7 cm flux. Unlike Jupiter, X-rays from Saturn's polar (auroral) region have characteristics similar to those from its disk. This report, combined with earlier studies, establishes that disk X-ray emissions of the giant planets Saturn and Jupiter are directly regulated by processes happening on the Sun. We suggest that these emissions could be monitored to study X-ray flaring from solar active regions when they are on the far side and not visible to Near-Earth space weather satellites.

  6. X-ray laser; Roentgenlaser

    Energy Technology Data Exchange (ETDEWEB)

    Samuelsen, Emil J.; Breiby, Dag W.

    2009-07-01

    X-ray is among the most important research tools today, and has given priceless contributions to all disciplines within the natural sciences. State of the art in this field is called XFEL, X-ray Free Electron Laser, which may be 10 thousand million times stronger than the x-rays at the European Synchrotron Radiation Facility in Grenoble. In addition XFEL has properties that allow the study of processes which previously would have been impossible. Of special interest are depictions on atomic- and molecular level by the use of x-ray holographic methods, and being able to study chemical reactions in nature's own timescale, the femtosecond. Conclusion: The construction of x-ray lasers is a natural development in a scientific field which has an enormous influence on the surrounding society. While the discovery of x-ray was an important breakthrough in itself, new applications appear one after the other: Medical depiction, dissemination, diffraction, DNA and protein structures, synchrotron radiation and tomography. There is reason to believe that XFEL implies a technological leap as big as the synchrotrons some decades ago. As we are now talking about studies of femtosecond and direct depiction of chemical reactions, it is obvious that we are dealing with a revolution to come, with extensive consequences, both scientifically and culturally. (EW)

  7. Direct X-ray photoconversion in flexible organic thin film devices operated below 1 V

    Science.gov (United States)

    Basiricò, Laura; Ciavatti, Andrea; Cramer, Tobias; Cosseddu, Piero; Bonfiglio, Annalisa; Fraboni, Beatrice

    2016-10-01

    The application of organic electronic materials for the detection of ionizing radiations is very appealing thanks to their mechanical flexibility, low-cost and simple processing in comparison to their inorganic counterpart. In this work we investigate the direct X-ray photoconversion process in organic thin film photoconductors. The devices are realized by drop casting solution-processed bis-(triisopropylsilylethynyl)pentacene (TIPS-pentacene) onto flexible plastic substrates patterned with metal electrodes; they exhibit a strong sensitivity to X-rays despite the low X-ray photon absorption typical of low-Z organic materials. We propose a model, based on the accumulation of photogenerated charges and photoconductive gain, able to describe the magnitude as well as the dynamics of the X-ray-induced photocurrent. This finding allows us to fabricate and test a flexible 2 × 2 pixelated X-ray detector operating at 0.2 V, with gain and sensitivity up to 4.7 × 104 and 77,000 nC mGy-1 cm-3, respectively.

  8. X-ray-to-current signal conversion characteristics of trench-structured photodiodes for direct-conversion-type silicon X-ray sensor

    Science.gov (United States)

    Ariyoshi, Tetsuya; Funaki, Shota; Sakamoto, Kenji; Baba, Akiyoshi; Arima, Yutaka

    2017-04-01

    To reduce the radiation dose required in medical X-ray diagnoses, we propose a high-sensitivity direct-conversion-type silicon X-ray sensor that uses trench-structured photodiodes. This sensor is advantageous in terms of its long device lifetime, noise immunity, and low power consumption because of its low bias voltage. With this sensor, it is possible to detect X-rays with almost 100% efficiency; sensitivity can therefore be improved by approximately 10 times when compared with conventional indirect-conversion-type sensors. In this study, a test chip was fabricated using a single-poly single-metal 0.35 µm process. The formed trench photodiodes for the X-ray sensor were approximately 170 and 300 µm deep. At a bias voltage of 25 V, the absorbed X-ray-to-current signal conversion efficiencies were 89.3% (theoretical limit; 96.7%) at a trench depth of 170 µm and 91.1% (theoretical limit; 94.3%) at a trench depth of 300 µm.

  9. MAXI/GSC detection of weak X-ray enhancement from the direction of NGC 6440

    Science.gov (United States)

    Negoro, H.; Ueno, S.; Tomida, H.; Ishikawa, M.; Sugawara, Y.; Isobe, N.; Shimomukai, R.; Mihara, T.; Sugizaki, M.; Nakahira, S.; Iwakiri, W.; Shidatsu, M.; Yatabe, F.; Takao, Y.; Matsuoka, M.; Kawai, N.; Sugita, S.; Yoshii, T.; Tachibana, Y.; Harita, S.; Morita, K.; Yoshida, A.; Sakamoto, T.; Serino, M.; Kawakubo, Y.; Kitaoka, Y.; Hashimoto, T.; Tsunemi, H.; Yoneyama, T.; Nakajima, M.; Kawase, T.; Sakamaki, A.; Ueda, Y.; Hori, T.; Tanimoto, A.; Oda, S.; Tsuboi, Y.; Nakamura, Y.; Sasaki, R.; Kawai, H.; Yamauchi, M.; Hanyu, C.; Hidaka, K.; Kawamuro, T.; Yamaoka, K.

    2017-10-01

    MAXI/GSC detects weak X-ray enhancement from the direction of the globular cluster NGC 6440. The 4-10 keV X-ray flux has been increasing since around 2017 September 29. Using data in 7 scan transits from 23:08 on October 3 to 06:07 on October 4, we obtain the source position at (R.A., Dec) = (267.335 deg, -20.047 deg) = (17 49 20, -20 02 49) (J2000) with a statistical 90% C.L. elliptical error region with long and short radii of 0.38 deg and 0.28 deg, respectively.

  10. Test of high-angular-resolution X-ray photoelectron diffraction and holographic imaging for c(2 × 2)S on Ni(001)

    Science.gov (United States)

    Saiki, R. S.; Kaduwela, A. P.; Kim, Y. J.; Friedman, D. J.; Osterwalder, J.; Thevuthasan, S.; Fadley, C. S.

    1992-12-01

    We have obtained azimuthal X-ray photoelectron diffraction (XPD) data with a high angular resolution of ± 1.5° for S2p emission from the well-defined surface structure of c(2 × 2)S on Ni(001). The relatively high position of the adsorbate with respect to the substrate makes this a stringent test case of the structural sensitivity of forward-scattering-dominated XPD. With this higher resolution, the data are nonetheless found to be sensitive to atomic structure, including in particular both the vertical height of S above Ni ( z) and the first-to-second layer Ni interplanar spacing ( d12). A single scattering cluster (SSC) theoretical analysis using R-factors to judge goodness of fit yields z = 1.39 ± 0.05 Å and d 12 = 1.86 ± 0.05 Å, in excellent agreement with other recent experimental and theoretical studies. This analysis also indicates that clusters of up to at least 25 Å in radius (200-250 atoms) are needed to accurately describe all of the diffraction fine structure observed; thus, although XPD is primarily a short-range order probe, high-resolution data provides sensitivity to order that may go out as far as 10-15 neighbor shells. For takeoff angles with respect to the surface of less than about 10°, multiple scattering effects appear to become more important, as verified by fully converged multiple scattering cluster (MSC) calculations; however, for takeoff angles larger than 10°, these effects fall away rapidly, making a single-scattering analysis of such data still a useful approach. Finally, we have analyzed our experimental data and SSC simulations of it using recently suggested Fourier-transform holographic inversion methods. Although our data are too limited to permit fully accurate holographic imaging, features associated with the nearest neighbor S atoms in the adsorbate overlayer are seen in both experimental and theoretical images. In addition, the theoretical calculations indicate that the atomic images can be improved if: the solid angle

  11. Direct Measurement of the X-ray Time-Delay Transfer Function in Active Galactic Nuclei

    CERN Document Server

    Legg, E; Turner, T J; Giustini, M; Reeves, J N; Kraemer, S B

    2012-01-01

    The origin of the observed time lags, in nearby active galactic nuclei (AGN), between hard and soft X-ray photons is investigated using new XMM-Newton data for the narrow-line Seyfert I galaxy Ark 564 and existing data for 1H0707-495 and NGC 4051. These AGN have highly variable X-ray light curves that contain frequent, high peaks of emission. The averaged light curve of the peaks is directly measured from the time series, and it is shown that (i) peaks occur at the same time, within the measurement uncertainties, at all X-ray energies, and (ii) there exists a substantial tail of excess emission at hard X-ray energies, which is delayed with respect to the time of the main peak, and is particularly prominent in Ark 564. Observation (i) rules out that the observed lags are caused by Comptonization time delays and disfavors a simple model of propagating fluctuations on the accretion disk. Observation (ii) is consistent with time lags caused by Compton-scattering reverberation from material a few thousand light-se...

  12. Direct Measurement of Mammographic X-Ray Spectra with a Digital CdTe Detection System

    Directory of Open Access Journals (Sweden)

    Giuseppe Raso

    2012-06-01

    Full Text Available In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP system, for high-rate X-ray spectroscopy in mammography (1–30 keV. The DPP system performs a height and shape analysis of the detector pulses, sampled and digitized by a 14-bit, 100 MHz ADC. We show the results of the characterization of the detection system both at low and high photon counting rates by using monoenergetic X-ray sources and a nonclinical X-ray tube. The detection system exhibits excellent performance up to 830 kcps with an energy resolution of 4.5% FWHM at 22.1 keV. Direct measurements of clinical molybdenum X-ray spectra were carried out by using a pinhole collimator and a custom alignment device. A comparison with the attenuation curves and the half value layer values, obtained from the measured and simulated spectra, from an ionization chamber and from a solid state dosimeter, also shows the accuracy of the measurements. These results make the proposed detection system a very attractive tool for both laboratory research, calibration of dosimeters and advanced quality controls in mammography.

  13. Studies of multilayer structure in depth direction by soft X-ray spectroscopy

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    It is demonstrated that two kinds of soft X-ray spectroscopy are useful as nondestructive methods to investigate multilayer structures modified by interdiffusion or by chemical reaction of adjoining layers in depth direction. One is the total electron yield (TEY) spectroscopy involving angular dependence measurement. Using this method, it was found that in LiF/Si/LiF trilayers, the Si layers exhibited a characteristic similar to porous Si, and in CaF2/Si/CaF2 trilayers, it was found that CaF2 segregated through the Si layer. Moreover, it has been shown that the thickness of the top layer of a Mo/Si X-ray multilayer can be determined by analyzing TEY signals generated by the standing wave. The other is the soft X-ray emission spectroscopy involving spectral shape analysis. Using this method,it was found that in Mo/Si X-ray multilayers, the interdiffusion or chemical reaction giving rise to deterioration of reflectance character occurs in as-deposited samples as well as in heated samples. In antiferromagnetic Fe/Si multilayers, it was confirmed that there was no existence of pure Si layers, but insulating FeSi2 layers were present. This result suggests that the source of antiferromagnetic coupling is not conduction electrons but quantum wave interference.

  14. Direct X-Ray Imaging of Transient Spin Accumulation near a Ferromagnet/Nonmagnet Interface

    Science.gov (United States)

    Chen, Zhao; Kukreja, Roopali; Bonetti, Stefano; Backes, Dirk; Kent, Andrew; Katine, Jordan; Durr, Hermann; Ohldag, Hendrik; Stohr, Joachim

    2015-03-01

    The physics of spin transport across a ferromagnet/nonmagnet interface is not well understood, even though such interfaces are common in spintronic devices. We use time-resolved x-ray spectro-microscopy to directly image transient spin accumulation in a Cu film caused by an injected spin current from an adjacent Co film. The measurement uses element-specific, circularly polarized x-rays detected via a scanning transmission x-ray microscope (STXM) in conjunction with 1.28MHz temporal modulation for remarkably increased x-ray sensitivity to spin signals. The transient moments per atom within the spin diffusion length from the interface were measured to be 8 x 10-5μB per Cu atom and 1.5 x 10-4μB per Co atom. The transient spin signal in Cu is found to be confined to states at the Fermi level, as expected, but we also observe a second peak of the same spin polarization in the spin accumulation signal that is 0.7eV higher than Fermi. The transient moments in the 28nm thick Cu layer exhibit the same spin sign as both the hybridization-induced static spins in Cu at the Cu/Co interface and the spins in the Co film. In contrast, the transient moments in the Co layer have the opposite sign, consistent with magnetization depleting from the Co polarizing layer.

  15. Impulsive solar X-ray bursts. 4: Polarization, directivity and spectrum of the reflected and total bremsstrahlung radiation from a beam of electrons directed toward the photosphere

    Science.gov (United States)

    Langer, S. H.; Petrosian, V.

    1976-01-01

    A Monte Carlo method is described for evaluation of the spectrum, directivity and polarization of X-rays diffusely reflected from stellar photospheres. the accuracy of the technique is evaluated through comparison with analytic results. Using the characteristics of the incident X-rays of the model for solar X-ray flares, the spectrum, directivity and polarization of the reflected and the total X-ray fluxes are evaluated. The results are compared with observations.

  16. Direct and secondary nuclear excitation with x-ray free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Gunst, Jonas; Wu, Yuanbin, E-mail: yuanbin.wu@mpi-hd.mpg.de; Kumar, Naveen; Keitel, Christoph H.; Pálffy, Adriana, E-mail: Palffy@mpi-hd.mpg.de [Max-Planck-Institut für Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany)

    2015-11-15

    The direct and secondary nuclear excitation produced by an x-ray free electron laser when interacting with a solid-state nuclear target is investigated theoretically. When driven at the resonance energy, the x-ray free electron laser can produce direct photoexcitation. However, the dominant process in that interaction is the photoelectric effect producing a cold and very dense plasma in which also secondary processes such as nuclear excitation by electron capture may occur. We develop a realistic theoretical model to quantify the temporal dynamics of the plasma and the magnitude of the secondary excitation therein. Numerical results show that depending on the nuclear transition energy and the temperature and charge states reached in the plasma, secondary nuclear excitation by electron capture may dominate the direct photoexcitation by several orders of magnitude, as it is the case for the 4.8 keV transition from the isomeric state of {sup 93}Mo, or it can be negligible, as it is the case for the 14.4 keV Mössbauer transition in {sup 57}Fe. These findings are most relevant for future nuclear quantum optics experiments at x-ray free electron laser facilities.

  17. Full three-dimensional direction-dependent x-ray scattering tomography

    Science.gov (United States)

    Zhu, Zheyuan; Pang, Shuo

    2017-03-01

    Small-angle X-ray scattering (SAXS) detects the angular-dependent, coherently scattered X-ray photons, which provide improved contrast among different types of tissues or materials in medical diagnosis and material characterizations. By combining SAXS with computed tomography (CT), coherent scattering computed tomography (CSCT) enables the detection of spatially-resolved, material-specific scattering profile inside an extended object. However, conventional CSCT lacks the ability to distinguish direction-dependent coherent scattering signal, because of its assumptions that the materials are amorphous with isotropic scattering profiles. To overcome this issue, we propose a new CSCT imaging strategy, which can resolve the three-dimensional scattering profile for each object pixel, by incorporating detector movement into each CSCT projection measurement. The full reconstruction of the three-dimensional momentum transfer profile of a two-dimensional object has been successfully demonstrated. Our setup only requires a table-top Xray source and a panel detector. The presented method demonstrates the potential to achieve low-cost, high-specificity X-ray tissue imaging and material characterization.

  18. A directly converting high-resolution intra-oral X-ray imaging sensor

    CERN Document Server

    Spartiotis, K; Schulman, T; Puhakka, K; Muukkonen, K

    2003-01-01

    A digital intra-oral X-ray imaging sensor with an active area of 3.6x2.9 cm sup 2 and consisting of six charge-integrating CMOS signal readout circuits bump bonded to one high-resistivity silicon pixel detector has been developed and tested. The pixel size is 35 mu m. The X-rays entering the sensor window are converted directly to electrical charge in the depleted detector material yielding minimum lateral signal spread and maximum image sharpness. The signal charge is collected on the gates of the input field effect transistors of the CMOS signal readout circuits. The analog signal readout is performed by multiplexing in the current mode independent of the signal charge collection enabling multiple readout cycles with negligible dead time and thus imaging with wide dynamic range. Since no intermediate conversion material of X-rays to visible light is needed, the sensor structure is very compact. The analog image signals are guided from the sensor output through a thin cable to signal processing, AD conversio...

  19. Direct analysis of biological samples by total reflection X-ray fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Lue M, Marco P. [Unidad de Analisis Instrumental, Departamento de Quimica y Suelos, Decanato de Agronomia, Universidad Centro-occidental Lisandro Alvarado, Apartado Postal 4076, Cabudare 3023 (Venezuela)]. E-mail: luemerumarco@yahoo.es; Hernandez-Caraballo, Edwin A. [Instituto Venezolano-Andino para la Investigacion Quimica (IVAIQUIM), Facultad de Ciencias, Universidad de los Andes, Merida 5101 (Venezuela)

    2004-08-31

    The technique of total reflection X-ray fluorescence (TXRF) is well suited for the direct analysis of biological samples due to the low matrix interferences and simultaneous multi-element nature. Nevertheless, biological organic samples are frequently analysed after digestion procedures. The direct determination of analytes requires shorter analysis time, low reactive consumption and simplifies the whole analysis process. On the other hand, the biological/clinical samples are often available in minimal amounts and routine studies require the analysis of large number of samples. To overcome the difficulties associated with the analysis of organic samples, particularly of solid ones, different procedures of sample preparation and calibration to approach the direct analysis have been evaluated: (1) slurry sampling, (2) Compton peak standardization, (3) in situ microwave digestion, (4) in situ chemical modification and (5) direct analysis with internal standardization. Examples of analytical methods developed by our research group are discussed. Some of them have not been previously published, illustrating alternative strategies for coping with various problems that may be encountered in the direct analysis by total reflection X-ray fluorescence spectrometry.

  20. Application of direct peak analysis to energy dispersive x-ray fluorescence spectra

    Energy Technology Data Exchange (ETDEWEB)

    Nielson, K.K.

    1977-07-01

    A modified Covell method for direct peak analysis has been applied to energy dispersive x-ray fluorescence spectra. The method is background independent and is well-suited to computerized data reduction. It provides acceptable precision, minimizes errors from instrumental gain shift, and permits peak overlap correction. Peak overlap errors exhibit both positive and negative nodes as a function of peak separation distance, and are corrected using concentration ratios determined from thin, single-element standards. Peak precisions and overlaps are evaluated as a function of window width to aid in width selection. Least-square polynomial smoothing prior to peak analysis significantly improves peak area precisions without significantly affecting their accuracies.

  1. Direct and secondary nuclear excitation with x-ray free-electron lasers

    CERN Document Server

    Gunst, Jonas; Kumar, Naveen; Keitel, Christoph H; Pálffy, Adriana

    2015-01-01

    The direct and secondary nuclear excitation produced by an x-ray free electron laser when interacting with a solid-state nuclear target is investigated theoretically. When driven at the resonance energy, the x-ray free electron laser can produce direct photoexcitation. However, the dominant process in that interaction is the photoelectric effect producing a cold and very dense plasma in which also secondary processes such as nuclear excitation by electron capture may occur. We develop a realistic model to quantify the temporal dynamics of the plasma and the magnitude of the secondary excitation therein. Numerical results show that depending on the nuclear transition energy and the temperature and charge states reached in the plasma, secondary nuclear excitation by electron capture may dominate the direct photoexcitation by several orders of magnitude, as it is the case for the 4.8 keV transition from the isomeric state of $^{93}$Mo, or it can be negligible, as it is the case for the 14.4 keV M\\"ossbauer trans...

  2. Direct Comparison of the X-Ray Emission and Absorption of Cerium Oxide

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, J G; Yu, S W; Chung, B W; Waddill, G D; Denlinger, J D

    2010-11-24

    Bremstrahlung Isochromat Spectroscopy (BIS). The XES spectra were collected using a Specs electron gun for the excitation and the XES 350 grating monochromator and channel plate system from Scienta as the photon detection. Spectra were collected in 'normal mode,' where the electron gun kinetic energy (KE) and the energy position of the center of the channel plate were both fixed and the energy distribution in the photon (hv) spectrum was derived from the intensities distributed across the channel plate detector in the energy dispersal direction. The polycrystalline Ce sample was oxidized by exposure to air at ambient pressures. After introduction to the ultra-high vacuum system, the oxidized sample was bombarded with Ar, to clean the topmost surface region and stabilize the surface and near surface regions. Although CeO{sub 2} would be the thermodynamically preferred composition in an oxygen rich environment, the combination of a vacuum environment and ion etching may have driven the near surface region into a Ce{sub 2}O{sub 3} stoichiometry. XES data collection occurred with the sample at or near room temperature. The base pressure of the system was 3 x 10{sup -10} torr, but the pressure changed depending the energy and current of the electron gun. For example, with the XES measurements at KE = 3KeV, the pressure was approximately 8 to 9 x 10{sup -10} torr and the excitation current to the sample was typically 0.01 mA. More detail of the sample preparation and analysis can be found in Reference 1. The XAS experiments were performed at Beamline 8 of the Advance Light Source, as part of a larger collaboration. The ex situ sample used at the ALS was prepared in a fashion similar to that described above. X-ray Emission Spectroscopy (XES) and X-ray Absorption Spectroscopy (XAS), have been used to investigate the photon emission and absorption associated with the Ce3d{sub 5/2} and Ce3d{sub 3/2} core-levels in CeOxide. A comparison of the two processes and

  3. Direct observation of pentacene-thiol interaction using x-ray spectroscopy

    Science.gov (United States)

    Jia, Zhang; Lee, Vincent; Floreano, Luca; Verdini, Alberto; Cossaro, Albano; Morgante, Alberto; Kymissis, Ioannis

    2010-03-01

    There has been an intense interest in the surface modification of the source-drain electrodes for organic field effect transistors (OFETs) to improve their performance. A number of thiol based self assembled monolayers demonstrated improvements to the contact resistance and channel performance. Morphological improvements at the contacts, a change in the effective work function, and charge transfer between the thiols and the semiconductor have all been credited with the observed performance improvements. Using in-situ semiconductor deposition together with x-ray photoelectron spectroscopy and near-edge x-ray absorption fine structure, we are able to directly probe two technologically relevant OFET stacks. This work directly measures the interaction between pentacene and two thiols which have been associated to contact improvement: an electroneutral thiol (1-hexadecanethiol) and an electronegative thiol (pentafluorobenzenethiol). Based on our results we observe no chemical interaction between pentacene and the thiol. The electrical improvements to transistor performance, based on these systems, can be attributed to work function shifts of the contacts and morphological improvements of the organic semiconductor.

  4. Focal spot deblurring for high resolution direct conversion x-ray detectors

    Science.gov (United States)

    Setlur Nagesh, S. V.; Rana, R.; Russ, M.; Ionita, Ciprian N.; Bednarek, D. R.; Rudin, S.

    2016-03-01

    Small pixel high resolution direct x-ray detectors have the advantage of higher spatial sampling and decreased blurring characteristic. The limiting factors for such systems becomes the degradation due to the focal spot size. One solution is a smaller focal spot; however, this can limit the output of the x-ray tube. Here a software solution of deconvolving with an estimated focal spot blur is presented. To simulate images from a direct detector affected with focal-spot blur, first a set of high-resolution stent images (FRED from Microvention, Inc., Tustin, CA) were acquired using a 75μm pixel size Dexela-Perkin-Elmer detector and frame averaged to reduce quantum noise. Then the averaged image was blurred with a known Gaussian blur. To add noise to the blurred image a flat-field image was multiplied with the blurred image. Both the ideal and the noisy-blurred images were then deconvolved with the known Gaussian function using either threshold-based inverse filtering or Weiner deconvolution. The blur in the ideal image was removed and the details were recovered successfully. However, the inverse filtering deconvolution process is extremely susceptible to noise. The Weiner deconvolution process was able to recover more of the details of the stent from the noisy-blurred image, but for noisier images, stent details are still lost in the recovery process.

  5. Towards the reconstruction of 3D orientation information from direction-sensitive X-ray projections

    Energy Technology Data Exchange (ETDEWEB)

    Malecki, Andreas; Biernath, Thomas; Bech, Martin; Potdevin, Guillaume; Pfeiffer, Franz [Technische Univ. Muenchen (Germany). Dept. of Physics (E17); Technische Univ. Muenchen (Germany). Inst. of Medical Engineering (IMETUM); Lasser, Tobias [Technische Univ. Muenchen (Germany). Chair for Computer Aided Medical Procedures and Augmented Reality (CAMP)

    2011-07-01

    For medical in vivo applications the resolution of a computed tomography (CT) scan is limited by the acceptable patient received dose. Thus it does not allow to image microstructures in the body. Novel X-ray contrast mechanisms provide two additional signal channels, phase contrast and dark-field contrast. In this study we report on our progress to use the dark-field signal to gain micro-structural information by reconstructing a tensor field describing the local sample scattering power. For that purpose we developed an experimental setup composed of an X-ray tube, a Talbot Lau interferometer, an Euler cradle to orient the sample and a detector. This setup allows a direct measurement of the sample scattering strength in all directions. The reconstruction of several test samples is done using filtered back-projection or the algebraic reconstruction technique. The definition of the physical model behind the reconstructed quantity is obtained from a second ansatz by using 3D density map (micro-CT) data as an input to a computer simulation of the whole setup. We consider this project important for diagnostic improvements in the case of bone pathologies. (orig.)

  6. The suppression of direct collapse black hole formation by soft X-ray irradiation

    Science.gov (United States)

    Inayoshi, Kohei; Tanaka, Takamitsu L.

    2015-07-01

    The origin of supermassive black holes (SMBHs) in galactic nuclei is one of the major unsolved problems in astrophysics. One hypothesis is that they grew from ≳ 105 M⊙ black holes that formed in the `direct collapse' of massive gas clouds that have low concentrations of both metals and molecular hydrogen (H2). Such clouds could form in the early (z ≳ 10) Universe if pre-galactic gas is irradiated by H2-photodissociating, far-ultraviolet (FUV) light from a nearby star-forming galaxy. In this work, we re-examine the critical FUV flux Jcrit that is required to keep H2 photodissociated and lead to direct collapse. We submit that the same galaxies that putatively supply the extraordinary FUV fluxes required for direct collapse should also produce copious amounts of soft X-rays, which work to offset H2 photodissociation by increasing the ionization fraction and promoting H2 formation. Accounting for this effect increases the value of Jcrit by a factor of at least 3-10, depending on the brightness temperature of FUV radiation. This enhancement of Jcrit suppresses the abundance of potential direct collapse sites at z > 10 by several orders of magnitude. Recent studies - without accounting for the soft X-rays from the FUV source galaxies - had already arrived at large values of Jcrit that implied that direct collapse may occur too rarely to account for the observed abundance of high-redshift quasars. Our results suggest that Jcrit should be even higher than previously estimated, and pose an additional challenge for the direct collapse scenario via strong FUV radiation to explain the high-redshift quasar population.

  7. Positive or negative? The impact of X-ray feedback on the formation of direct collapse black hole seeds

    Science.gov (United States)

    Regan, John A.; Johansson, Peter H.; Wise, John H.

    2016-09-01

    A nearby source of Lyman-Werner (LW) photons is thought to be a central component in dissociating H2 and allowing for the formation of a direct collapse black hole seed. Nearby sources are also expected to produce copious amounts of hydrogen ionizing photons and X-ray photons. We study here the feedback effects of the X-ray photons by including a spectrum due to high-mass X-ray binaries on top of a galaxy with a stellar spectrum. We explicitly trace photon packages emerging from the nearby source and track the radiative and chemical effects of the multifrequency source (Ephoton = 0.76 eV → 7500 eV). We find that X-rays have a strongly negative feedback effect, compared to a stellar only source, when the radiative source is placed at a separation greater than ≳ 1 kpc. The X-rays heat the low and medium density gas in the envelope surrounding the collapsing halo suppressing the mass inflow. The result is a smaller enclosed mass compared to the stellar only case. However, for separations of ≲ 1 kpc, the feedback effects of the X-rays becomes somewhat neutral. The enhanced LW intensity at close separations dissociates more H2 and this gas is heated due to stellar photons alone, the addition of X-rays is then not significant. This distance dependence of X-ray feedback suggests that a Goldilocks zone exists close to a forming galaxy where X-ray photons have a much smaller negative feedback effect and ideal conditions exist for creating massive black hole seeds.

  8. Doses under automatic exposure control (AEC) for direct digital radiographic (DDR) X-ray systems.

    Science.gov (United States)

    Bowden, Louise; Faulkner, Ronan; Clancy, Conor; Gallagher, Aoife; Devine, Mark; Gorman, Dermot; O'Reilly, Geraldine; Dowling, Anita

    2011-09-01

    Current guidelines quote tolerances for automatic exposure control (AEC) device performance for X-ray systems as 'Baseline ± X %'. However, in the situation where a baseline figure has not yet been achieved, as in the case of commissioning assessments, this tolerance is not relevant. The purpose of this work is to provide mean doses for direct digital radiography (DDR) X-ray system, operating in AEC, against which comparisons can be made. Dose measurements have been recorded under AEC operation on 29 DDR detectors from three different manufacturers. Two different testing protocols were examined: (1) water equivalent phantoms in front of the DDR detector and (2) aluminium block at the tube head. The average patient exit dose, using the aluminium block was 4.6 μGy with the antiscatter grid in place and 4.0 μGy with the grid removed. Using the water phantoms, the average dose was measured at 17.1 μGy with the antiscatter grid in place and 5.4 μGy with grid removed. Based on these results, it is clear that different testing configurations significantly impact on the measured dose.

  9. Counting and integrating microelectronics development for direct conversion X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kraft, E.

    2008-02-15

    A novel signal processing concept for X-ray imaging with directly converting pixelated semiconductor sensors is presented. The novelty of this approach compared to existing concepts is the combination of charge integration and photon counting in every single pixel. Simultaneous operation of both signal processing chains extends the dynamic range beyond the limits of the individual schemes and allows determination of the mean photon energy. Medical applications such as X-ray computed tomography can benefit from this additional spectral information through improved contrast and the ability to determine the hardening of the tube spectrum due to attenuation by the scanned object. A prototype chip in 0.35-micrometer technology has been successfully tested. The pixel electronics are designed using a low-swing differential current mode logic. Key element is a configurable feedback circuit for the charge sensitive amplifier which provides continuous reset, leakage current compensation and replicates the input signal for the integrator. The thesis focusses on the electronic characterization of a second generation prototype chip and gives a detailed discussion of the circuit design. (orig.)

  10. Resolving the Crab Nebula with Direct Hard X-Ray Imaging

    Science.gov (United States)

    Swartz, Douglas A.; Ramsey, Brian D.; Tennant, Allyn F.; Dietz, Kurtis L.; Apple, Jeff A.; Gaskin, Jessica A.; Weisskopf, Martin

    2008-01-01

    We report the first direct hard (25--60 keV) X-ray imaging observation of the Crab Nebula that resolves structure to approximately 0.25 pc. The observation was performed over a 1.4 hour period during a balloon flight from Ft. Sumner, NM, on 2007 May 27. The source was detected in the energy band above the atmospheric cutoff at approx.25 keV and below the mirror graze angle cutoff at approx.60 keV. The image shows elongation about 25 degrees E of N in the direction along the plane of the torus (and perpendicular to the jet axis) with a slight surface-brightness enhancement NE of the pulsar. The spectrum within a 1.7 arcminute radius region centered on the Crab pulsar can be fitted with a Gamma=2 power law absorbed by an atmospheric column consistent with the balloon altitude at the time of observation.

  11. Design of hybrid sol gel films for direct x-ray and electron beam nanopatterning

    Science.gov (United States)

    Brusatin, Giovanna; Della Giustina, Gioia; Romanato, Filippo; Guglielmi, Massimo

    2008-04-01

    New epoxy based sol-gel organic inorganic materials, showing lithographic resist-like properties without the addition of any photocatalysts, are presented. To obtain a material sensitive to radiation, specific sol-gel syntheses based on an organically modified alkoxide containing an epoxy ring, 3-glycidoxypropyltrimethoxysilane (GPTMS), have been developed. The synthesis and the patternability of hybrid materials have been obtained controlling the inorganic crosslinking degree and with an almost total absence of organic polymerization. Two examples of directly patternable hybrid films, called GB and GGe, have been synthesized using acidic (GGe) and basic (GB) conditions and obtaining different compositions. After electron beam lithography (EBL) or x-ray synchrotron radiation lithography (XRL) the polymerization of the organic component of the sol-gel film occurs, generating a hardening of the structure after post-exposure baking. The exposed polymerized material becomes insoluble, determining a negative resist-like behaviour of the film: the lithographic process of nanopatterning results from the dissolution of the unexposed areas in proper solvents (developers). Spatial resolution of the order of 200 nm is reported and a contrast of 2.2 is achieved. The novelty of this work is that epoxy based materials, which have enhanced thermomechanical stability with respect to the more usual acrylic based resins, are directly nanopatterned for the first time by electron beam (EB) and/or x-ray beam radiation exposure without the aid of catalysts for polymerization. In contrast to common resists that are sacrificial layers of the fabrication process, direct patternable sol-gel hybrids constitute the final material of the devices. In fact, an example of doping with a light emitting dye is reported together with the achievement of directly patterned structures by EBL and XRL.

  12. X-Ray Radiographic Observation of Directional Solidification Under Microgravity: XRMON-GF Experiments on MASER12 Sounding Rocket Mission

    Science.gov (United States)

    Reinhart, G.; NguyenThi, H.; Bogno, A.; Billia, B.; Houltz, Y.; Loth, K.; Voss, D.; Verga, A.; dePascale, F.; Mathiesen, R. H.; Zimmermann, G.

    2012-01-01

    The European Space Agency (ESA) - Microgravity Application Promotion (MAP) programme entitled XRMON (In situ X-Ray MONitoring of advanced metallurgical processes under microgravity and terrestrial conditions) aims to develop and perform in situ X-ray radiography observations of metallurgical processes in microgravity and terrestrial environments. The use of X-ray imaging methods makes it possible to study alloy solidification processes with spatio-temporal resolutions at the scales of relevance for microstructure formation. XRMON has been selected for MASER 12 sounding rocket experiment, scheduled in autumn 2011. Although the microgravity duration is typically six minutes, this short time is sufficient to investigate a solidification experiment with X-ray radiography. This communication will report on the preliminary results obtained with the experimental set-up developed by SSC (Swedish Space Corporation). Presented results dealing with directional solidification of Al-Cu confirm the great interest of performing in situ characterization to analyse dynamical phenomena during solidification processes.

  13. How realistic UV spectra and X-rays suppress the abundance of direct collapse black holes

    Science.gov (United States)

    Latif, M. A.; Bovino, S.; Grassi, T.; Schleicher, D. R. G.; Spaans, M.

    2015-01-01

    Observations of high-redshift quasars at z > 6 indicate that they harbour supermassive black holes (SMBHs) of a billion solar masses. The direct collapse scenario has emerged as the most plausible way to assemble SMBHs. The nurseries for the direct collapse black holes are massive primordial haloes illuminated with an intense UV flux emitted by Population II (Pop II) stars. In this study, we compute the critical value of such a flux (J_{21}^crit) for realistic spectra of Pop II stars through three-dimensional cosmological simulations. We derive the dependence of J_{21}^crit on the radiation spectra, on variations from halo to halo, and on the impact of X-ray ionization. Our findings show that the value of J_{21}^crit is a few times 104 and only weakly depends on the adopted radiation spectra in the range between Trad = 2 × 104and105 K. For three simulated haloes of a few times 107 M⊙, J_{21}^crit varies from 2 × 104 to 5 × 104. The impact of X-ray ionization is almost negligible and within the expected scatter of J_{21}^crit for background fluxes of JX, 21 ≤ 0.1. The computed estimates of J_{21}^crit have profound implications for the quasar abundance at z = 10 as it lowers the number density of black holes forming through an isothermal direct collapse by a few orders of magnitude below the observed black hole density. However, the sites with moderate amounts of H2 cooling may still form massive objects sufficient to be compatible with observations.

  14. Studying fatigue damage evolution in uni-directional composites using x-ray computed tomography

    DEFF Research Database (Denmark)

    Mikkelsen, Lars Pilgaard

    , it will be possible to lower the costs of energy for wind energy based electricity. In the present work, a lab-source x-ray computed tomography equipment (Zeiss Xradia 520 Versa) has been used in connection with ex-situ fatigue testing of uni-directional composites in order to identify fibre failure during...... the fatigue loading. The load carrying laminates in wind turbine blades is typically based on a number of non-crimp fabrics in which the load carrying fibres are oriented in the axial direction of the blades. In order to ease the handling of the fabric during the dry fabric layup and to ensure a good...... alignment of the final laminates, approximately 10% of the fibres are oriented in secondary directions as so-called backing bundles and stitched to the uni-directionally oriented bundles. Due to the coarse structure of the non-crimp fabric, test samples with a larger cross-section (compared to other...

  15. Holographic Interferometry (HI), Infrared Vision and X-Ray Fluorescence (XRF) spectroscopy for the assessment of painted wooden statues: a new integrated approach

    Energy Technology Data Exchange (ETDEWEB)

    Sfarra, Stefano; Ambrosini, Dario; Paoletti, Domenica [University of L' Aquila, Department of Industrial and Information Engineering and Economics, Las.E.R. Laboratory, Loc. Monteluco di Roio, AQ (Italy); Ibarra-Castanedo, Clemente; Maldague, Xavier [Laval University, Computer Vision and Systems Laboratory, Department of Electrical and Computer Engineering, Quebec City (Canada); Ridolfi, Stefano [Ars Mensurae, Rome (Italy); Cerichelli, Giorgio [University of L' Aquila, Department of Physical and Chemical Sciences, Loc. Coppito, AQ (Italy)

    2014-06-15

    Wood has been routinely employed in decorative arts, as well as in sculptures and paintings (support) during the Middle Ages, because of its unique aesthetic virtues. It may safely be assumed that wood, as a material for monumental sculpture, was much more commonly employed in the mediaeval period than existing examples would seem to indicate (Bulletin of the metropolitan Museum of Art, 2013). Wood is easily obtainable; it could be carved and put in place with less difficulty than stone, it is chemically stable when dry, and its surface offers a compatible substrate for paint application. However, the use of wood is not without pitfalls, and requires an understanding of its anisotropic and hygroscopic nature. It is also dimensionally unstable and subject to deterioration by fungi and insects. Moisture-related dimensional changes are certainly among the most challenging problems in painting conservation. With the purpose of preventing important damages, the use of non-or microdestructive testing (NDT) techniques is undoubtedly of paramount interest for painted wooden statues of great value. This work has a threefold purpose: (1) to validate the effectiveness of an integrated approach using near-infrared (NIR) reflectography, square pulse thermography (SPT), and holographic interferometry (HI) techniques for discovering old repairs and/or inclusions of foreign materials in a wooden structure, (2) to confirm and approximately date the restoration carried out by x-ray fluorescence (XRF) spectroscopy and energy-dispersive x-ray spectroscopy (EDS) (that is assembled with a scanning electron microscopy - SEM) techniques, and (3) to combine into a multidisciplinary approach two quantitative NDT results coming from optical and thermographic methods. The subject of the present study was a statue named ''Virgin with her Child'' (XIV century), whose origins are mysterious and not properly documented. (orig.)

  16. Holographic Interferometry (HI), Infrared Vision and X-Ray Fluorescence (XRF) spectroscopy for the assessment of painted wooden statues: a new integrated approach

    Science.gov (United States)

    Sfarra, Stefano; Ibarra-Castanedo, Clemente; Ridolfi, Stefano; Cerichelli, Giorgio; Ambrosini, Dario; Paoletti, Domenica; Maldague, Xavier

    2014-06-01

    Wood has been routinely employed in decorative arts, as well as in sculptures and paintings (support) during the Middle Ages, because of its unique aesthetic virtues. It may safely be assumed that wood, as a material for monumental sculpture, was much more commonly employed in the mediaeval period than existing examples would seem to indicate (Bulletin of the metropolitan Museum of Art, 2013). Wood is easily obtainable; it could be carved and put in place with less difficulty than stone, it is chemically stable when dry, and its surface offers a compatible substrate for paint application. However, the use of wood is not without pitfalls, and requires an understanding of its anisotropic and hygroscopic nature. It is also dimensionally unstable and subject to deterioration by fungi and insects. Moisture-related dimensional changes are certainly among the most challenging problems in painting conservation. With the purpose of preventing important damages, the use of non-or microdestructive testing (NDT) techniques is undoubtedly of paramount interest for painted wooden statues of great value. This work has a threefold purpose: (1) to validate the effectiveness of an integrated approach using near-infrared (NIR) reflectography, square pulse thermography (SPT), and holographic interferometry (HI) techniques for discovering old repairs and/or inclusions of foreign materials in a wooden structure, (2) to confirm and approximately date the restoration carried out by x-ray fluorescence (XRF) spectroscopy and energy-dispersive x-ray spectroscopy (EDS) (that is assembled with a scanning electron microscopy—SEM) techniques, and (3) to combine into a multidisciplinary approach two quantitative NDT results coming from optical and thermographic methods. The subject of the present study was a statue named "Virgin with her Child" (XIV century), whose origins are mysterious and not properly documented.

  17. Impulsive solar X-ray bursts. III - Polarization, directivity, and spectrum of the reflected and total bremsstrahlung radiation from a beam of electrons directed toward the photosphere

    Science.gov (United States)

    Langer, S. H.; Petrosian, V.

    1977-01-01

    The paper presents the spectrum, directivity, and state of polarization of the bremsstrahlung radiation expected from a beam of high-energy electrons spiraling along radial magnetic field lines toward the photosphere. A Monte Carlo method is then described for evaluation of the spectrum, directivity, and polarization of X-rays diffusely reflected from stellar photospheres. The accuracy of the technique is evaluated through comparison with analytic results. The calculated characteristics of the incident X-rays are used to evaluate the spectrum, directivity, and polarization of the reflected and total X-ray fluxes. The results are compared with observations.

  18. How realistic UV spectra and X-rays suppress the abundance of direct collapse black holes

    CERN Document Server

    Latif, M A; Grassi, T; Schleicher, D R G; Spaans, M

    2014-01-01

    Observations of high redshift quasars at $z>6$ indicate that they harbor supermassive black holes (SMBHs) of a billion solar masses. The direct collapse scenario has emerged as the most plausible way to assemble SMBHs. The nurseries for the direct collapse black holes are massive primordial halos illuminated with an intense UV flux emitted by population II stars. In this study, we compute the critical value of such a flux ($J_{21}^{\\rm crit}$) for realistic spectra of pop II stars through three-dimensional cosmological simulations. We derive the dependence of $J_{21}^{\\rm crit}$ on the radiation spectra, on variations from halo to halo, and on the impact of X-ray ionization. Our findings show that the value of $J_{21}^{\\rm crit}$ is a few times $\\rm 10^4$ and only weakly depends on the adopted radiation spectra in the range between $T_{\\rm rad}=2 \\times 10^4-10^5$ K. For three simulated halos of a few times $\\rm 10^{7}$~M$_{\\odot}$, $J_{21}^{\\rm crit}$ varies from $\\rm 2 \\times 10^4 - 5 \\times 10^4$. The impa...

  19. Direct X-ray photoconversion in flexible organic thin film devices operated below 1 V.

    Science.gov (United States)

    Basiricò, Laura; Ciavatti, Andrea; Cramer, Tobias; Cosseddu, Piero; Bonfiglio, Annalisa; Fraboni, Beatrice

    2016-10-06

    The application of organic electronic materials for the detection of ionizing radiations is very appealing thanks to their mechanical flexibility, low-cost and simple processing in comparison to their inorganic counterpart. In this work we investigate the direct X-ray photoconversion process in organic thin film photoconductors. The devices are realized by drop casting solution-processed bis-(triisopropylsilylethynyl)pentacene (TIPS-pentacene) onto flexible plastic substrates patterned with metal electrodes; they exhibit a strong sensitivity to X-rays despite the low X-ray photon absorption typical of low-Z organic materials. We propose a model, based on the accumulation of photogenerated charges and photoconductive gain, able to describe the magnitude as well as the dynamics of the X-ray-induced photocurrent. This finding allows us to fabricate and test a flexible 2 × 2 pixelated X-ray detector operating at 0.2 V, with gain and sensitivity up to 4.7 × 10(4) and 77,000 nC mGy(-1) cm(-3), respectively.

  20. Direct observation of ultrafast atomic motion using time-resolved X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Shymanovich, U.

    2007-11-13

    This thesis is dedicated to the study of the atomic motion in laser irradiated solids on a picosecond to subpicosecond time-scale using the time-resolved X-ray diffraction technique. In the second chapter, the laser system, the laser-plasma based X-ray source and the experimental setup for optical pump / X-ray probe measurements were presented. Chapter 3 is devoted to the characterization and comparison of different types of X-ray optics. Chapter 4 presented the time-resolved X-ray diffraction experiments performed for this thesis. The first two sections of this chapter discuss the measurements of initially unexpected strain-induced transient changes of the integrated reflectivity of the X-ray probe beam. The elimination of the strain-induced transient changes of the integrated reflectivity represented an important prerequisite to perform the study of lattice heating in Germanium after femtosecond optical excitation by measuring the transient Debye-Waller effect. The third section describes the investigations of acoustic waves upon ultrafast optical excitation and discusses the two different pressure contributions driving them: the thermal and the electronic ones. (orig.)

  1. Direct observation of lithium polysulfides in lithium-sulfur batteries using operando X-ray diffraction

    Science.gov (United States)

    Conder, Joanna; Bouchet, Renaud; Trabesinger, Sigita; Marino, Cyril; Gubler, Lorenz; Villevieille, Claire

    2017-06-01

    In the on going quest towards lithium-battery chemistries beyond the lithium-ion technology, the lithium-sulfur system is emerging as one of the most promising candidates. The major outstanding challenge on the route to commercialization is controlling the so-called polysulfide shuttle, which is responsible for the poor cycling efficiency of the current generation of lithium-sulfur batteries. However, the mechanistic understanding of the reactions underlying the polysulfide shuttle is still incomplete. Here we report the direct observation of lithium polysulfides in a lithium-sulfur cell during operation by means of operando X-ray diffraction. We identify signatures of polysulfides adsorbed on the surface of a glass-fibre separator and monitor their evolution during cycling. Furthermore, we demonstrate that the adsorption of the polysulfides onto SiO2 can be harnessed for buffering the polysulfide redox shuttle. The use of fumed silica as an electrolyte additive therefore significantly improves the specific charge and Coulombic efficiency of lithium-sulfur batteries.

  2. Theoretical approach to direct resonant inelastic X-ray scattering on magnets and superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Marra, Pasquale

    2015-10-26

    The capability to probe the dispersion of elementary spin, charge, orbital, and lattice excitations has positioned resonant inelastic X-ray scattering (RIXS) at the forefront of photon science. In this work, we will investigate how RIXS can contribute to a deeper understanding of the orbital properties and of the pairing mechanism in unconventional high-temperature superconductors. In particular, we show how direct RIXS spectra of magnetic excitations can reveal long-range orbital correlations in transition metal compounds, by discriminating different kind of orbital order in magnetic and antiferromagnetic systems. Moreover, we show how RIXS spectra of quasiparticle excitations in superconductors can measure the superconducting gap magnitude, and reveal the presence of nodal points and phase differences of the superconducting order parameter on the Fermi surface. This can reveal the properties of the underlying pairing mechanism in unconventional superconductors, in particular cuprates and iron pnictides, discriminating between different superconducting order parameter symmetries, such as s,d (singlet pairing) and p wave (triplet pairing).

  3. X-ray Cavities in Galaxy Groups and Clusters: Central Gas Entropy Excess as Direct Evidence for AGN Feedback

    Indian Academy of Sciences (India)

    Yu Wang

    2011-03-01

    Observations of X-ray jets and cavities in clusters of galaxies observed by Chandra are briefly reviewed. A recent study on the excess of central gas entropy, which can be considered as direct evidence for AGN feedback in galaxy groups and clusters is presented. An expanded account of this study has been presented in RAA (Wang et al. 2010).

  4. X-ray Structure of Native Scorpion Toxin BmBKTx1 by Racemic Protein Crystallography Using Direct Methods

    Energy Technology Data Exchange (ETDEWEB)

    Mandal, Kalyaneswar; Pentelute, Brad L.; Tereshko, Valentina; Kossiakoff, Anthony A.; Kent, Stephen B.H.; (UC)

    2009-04-08

    Racemic protein crystallography, enabled by total chemical synthesis, has allowed us to determine the X-ray structure of native scorpion toxin BmBKTx1; direct methods were used for phase determination. This is the first example of a protein racemate that crystallized in space group I41/a.

  5. Solution of Ge(111)-(4x4)-Ag structure using direct methods applied to X-ray diffraction data

    DEFF Research Database (Denmark)

    Collazo-Davila, C.; Grozea, D.; Marks, L.D.

    1998-01-01

    A structure model for the Ge(111)-(4 x 4)-Ag surface is proposed. The model was derived by applying direct methods to surface X-ray diffraction data. It is a missing top layer reconstruction with six Ag atoms placed on Ge substitutional sites in one triangular subunit of the surface unit cell...

  6. Using "Tender" X-ray Ambient Pressure X-Ray Photoelectron Spectroscopy as A Direct Probe of Solid-Liquid Interface.

    Science.gov (United States)

    Axnanda, Stephanus; Crumlin, Ethan J; Mao, Baohua; Rani, Sana; Chang, Rui; Karlsson, Patrik G; Edwards, Mårten O M; Lundqvist, Måns; Moberg, Robert; Ross, Phil; Hussain, Zahid; Liu, Zhi

    2015-05-07

    We report a new method to probe the solid-liquid interface through the use of a thin liquid layer on a solid surface. An ambient pressure XPS (AP-XPS) endstation that is capable of detecting high kinetic energy photoelectrons (7 keV) at a pressure up to 110 Torr has been constructed and commissioned. Additionally, we have deployed a "dip &pull" method to create a stable nanometers-thick aqueous electrolyte on platinum working electrode surface. Combining the newly constructed AP-XPS system, "dip &pull" approach, with a "tender" X-ray synchrotron source (2 keV-7 keV), we are able to access the interface between liquid and solid dense phases with photoelectrons and directly probe important phenomena occurring at the narrow solid-liquid interface region in an electrochemical system. Using this approach, we have performed electrochemical oxidation of the Pt electrode at an oxygen evolution reaction (OER) potential. Under this potential, we observe the formation of both Pt(2+) and Pt(4+) interfacial species on the Pt working electrode in situ. We believe this thin-film approach and the use of "tender" AP-XPS highlighted in this study is an innovative new approach to probe this key solid-liquid interface region of electrochemistry.

  7. X-Ray Surveys

    CERN Document Server

    Giommi, P; Perri, M

    1998-01-01

    A review of recent developments in the field of X-ray surveys, especially in the hard (2-10 and 5-10 keV) bands, is given. A new detailed comparison between the measurements in the hard band and extrapolations from ROSAT counts, that takes into proper account the observed distribution of spectral slopes, is presented. Direct comparisons between deep ROSAT and BeppoSAX images show that most hard X-ray sources are also detected at soft X-ray energies. This may indicate that heavily cutoff sources, that should not be detectable in the ROSAT band but are expected in large numbers from unified AGN schemes, are in fact detected because of the emerging of either non-nuclear components, or of reflected, or partially transmitted nuclear X-rays. These soft components may complicate the estimation of the soft X-ray luminosity function and cosmological evolution of AGN.

  8. Use of a solar panel as a directionally sensitive large-area radiation monitor for direct and scattered x-rays and gamma-rays.

    Science.gov (United States)

    Abdul-Majid, S

    1987-01-01

    The characteristics of a 25.4 X 91 cm solar cell panel used as an x-ray and gamma-ray radiation monitor are presented. Applications for monitoring the primary x-ray beam are described at different values of operating currents and voltages as well as for directional dependence of scattered radiation. Other applications in gamma-ray radiography are also given. The detector showed linear response to both x-ray and gamma-ray exposures. The equipment is rigid, easy to use, relatively inexpensive and requires no power supply or any complex electronic equipment.

  9. Spectroscopic imaging, diffraction, and holography with x-ray photoemission

    Energy Technology Data Exchange (ETDEWEB)

    1992-02-01

    X-ray probes are capable of determining the spatial structure of an atom in a specific chemical state, over length scales from about a micron all the way down to atomic resolution. Examples of these probes include photoemission microscopy, energy-dependent photoemission diffraction, photoelectron holography, and X-ray absorption microspectroscopy. Although the method of image formation, chemical-state sensitivity, and length scales can be very different, these X-ray techniques share a common goal of combining a capability for structure determination with chemical-state specificity. This workshop will address recent advances in holographic, diffraction, and direct imaging techniques using X-ray photoemission on both theoretical and experimental fronts. A particular emphasis will be on novel structure determinations with atomic resolution using photoelectrons.

  10. Direct X-ray detection with hybrid solar cells based on organolead halide perovskites

    Science.gov (United States)

    Gill, Hardeep Singh; Elshahat, Bassem; Sajo, Erno; Kumar, Jayant; Kokil, Akshay; Zygmanski, Piotr; Li, Lian; Mosurkal, Ravi

    2014-03-01

    Organolead halide perovskite materials are attracting considerable interest due to their exceptional opto-electronic properties, such as, high charge carrier mobilities, high exciton diffusion length, high extinction coefficients and broad-band absorption. These interesting properties have enabled their application in high performance hybrid photovoltaic devices. The high Z value of their constituents also makes these materials efficient for absorbing X-rays. Here we will present on the efficient use of hybrid solar cells based on organolead perovskite materials as X-ray detectors. Hybrid solar cells based on CH3NH3PbI3 were fabricated using facile processing techniques on patterned indium tin oxide coated glass substrates. The solar cells typically had a planar configuration of ITO/CH3NH3PbI3/P3HT/Ag. High sensitivity for X-rays due to high Z value, larger carrier mobility and better charge collection was observed. Detecting X-rays with energies relevant to medical oncology applications opens up the potential for diagnostic imaging applications.

  11. An X-ray diffraction study of direct-bonded silicon interfaces

    DEFF Research Database (Denmark)

    Howes, P.B.; Benamara, M.; Grey, F.

    1998-01-01

    Semiconductor wafer bonding techniques have been used to create a giant twist grain boundary from two Si(001) wafers. We show, using X-ray diffraction measurements that after annealing the interface forms a highly ordered superstructure with relaxations extending to many layers into the crystals...

  12. Toward Low-Voltage and Bendable X-Ray Direct Detectors Based on Organic Semiconducting Single Crystals.

    Science.gov (United States)

    Ciavatti, Andrea; Capria, Ennio; Fraleoni-Morgera, Alessandro; Tromba, Giuliana; Dreossi, Diego; Sellin, Paul J; Cosseddu, Piero; Bonfiglio, Annalisa; Fraboni, Beatrice

    2015-11-25

    Organic materials have been mainly proposed as ionizing radiation detectors in the indirect conversion approach. The first thin and bendable X-ray direct detectors are realized (directly converting X-photons into an electric signal) based on organic semiconducting single crystals that possess enhanced sensitivity, low operating voltage (≈5 V), and a minimum detectable dose rate of 50 μGy s(-1) .

  13. Amorphous and Polycrystalline Photoconductors for Direct Conversion Flat Panel X-Ray Image Sensors

    Directory of Open Access Journals (Sweden)

    Karim S. Karim

    2011-05-01

    Full Text Available In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs. We first outline the essential requirements for an ideal large area photoconductor for use in a FPXI, and discuss how some of the current amorphous and polycrystalline semiconductors fulfill these requirements. At present, only stabilized amorphous selenium (doped and alloyed a-Se has been commercialized, and FPXIs based on a-Se are particularly suitable for mammography, operating at the ideal limit of high detective quantum efficiency (DQE. Further, these FPXIs can also be used in real-time, and have already been used in such applications as tomosynthesis. We discuss some of the important attributes of amorphous and polycrystalline x-ray photoconductors such as their large area deposition ability, charge collection efficiency, x-ray sensitivity, DQE, modulation transfer function (MTF and the importance of the dark current. We show the importance of charge trapping in limiting not only the sensitivity but also the resolution of these detectors. Limitations on the maximum acceptable dark current and the corresponding charge collection efficiency jointly impose a practical constraint that many photoconductors fail to satisfy. We discuss the case of a-Se in which the dark current was brought down by three orders of magnitude by the use of special blocking layers to satisfy the dark current constraint. There are also a number of polycrystalline photoconductors, HgI2 and PbO being good examples, that show potential for commercialization in the same way that multilayer stabilized a-Se x-ray photoconductors were developed for commercial applications. We highlight the unique nature of avalanche multiplication in a-Se and how it has led to the development of the commercial HARP video-tube. An all solid state version of the

  14. Amorphous and polycrystalline photoconductors for direct conversion flat panel x-ray image sensors.

    Science.gov (United States)

    Kasap, Safa; Frey, Joel B; Belev, George; Tousignant, Olivier; Mani, Habib; Greenspan, Jonathan; Laperriere, Luc; Bubon, Oleksandr; Reznik, Alla; DeCrescenzo, Giovanni; Karim, Karim S; Rowlands, John A

    2011-01-01

    In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs). We first outline the essential requirements for an ideal large area photoconductor for use in a FPXI, and discuss how some of the current amorphous and polycrystalline semiconductors fulfill these requirements. At present, only stabilized amorphous selenium (doped and alloyed a-Se) has been commercialized, and FPXIs based on a-Se are particularly suitable for mammography, operating at the ideal limit of high detective quantum efficiency (DQE). Further, these FPXIs can also be used in real-time, and have already been used in such applications as tomosynthesis. We discuss some of the important attributes of amorphous and polycrystalline x-ray photoconductors such as their large area deposition ability, charge collection efficiency, x-ray sensitivity, DQE, modulation transfer function (MTF) and the importance of the dark current. We show the importance of charge trapping in limiting not only the sensitivity but also the resolution of these detectors. Limitations on the maximum acceptable dark current and the corresponding charge collection efficiency jointly impose a practical constraint that many photoconductors fail to satisfy. We discuss the case of a-Se in which the dark current was brought down by three orders of magnitude by the use of special blocking layers to satisfy the dark current constraint. There are also a number of polycrystalline photoconductors, HgI(2) and PbO being good examples, that show potential for commercialization in the same way that multilayer stabilized a-Se x-ray photoconductors were developed for commercial applications. We highlight the unique nature of avalanche multiplication in a-Se and how it has led to the development of the commercial HARP video-tube. An all solid state version of the HARP has been

  15. DIRECT SPATIAL ASSOCIATION OF AN X-RAY FLARE WITH THE ERUPTION OF A SOLAR QUIESCENT FILAMENT

    Energy Technology Data Exchange (ETDEWEB)

    Holman, Gordon D.; Foord, Adi, E-mail: gordon.d.holman@nasa.gov [Code 671, NASA Goddard Space Flight Center, Greenbelt, MD 20771 (United States)

    2015-05-10

    Solar flares primarily occur in active regions. Hard X-ray flares have been found to occur only in active regions. They are often associated with the eruption of active region filaments and coronal mass ejections (CMEs). CMEs can also be associated with the eruption of quiescent filaments, not located in active regions. Here we report the first identification of a solar X-ray flare outside an active region observed by the Ramaty High Energy Solar Spectroscopic Imager (RHESSI). The X-ray emission was directly associated with the eruption of a long, quiescent filament and fast CME. Images from RHESSI show this flare emission to be located along a section of the western ribbon of the expanding, post-eruption arcade. EUV images from the Solar Dynamics Observatory Atmospheric Imaging Assembly show no connection between this location and nearby active regions. Therefore the flare emission is found not to be located in or associated with an active region. However, a nearby, small, magnetically strong dipolar region provides a likely explanation for the existence and location of the flare X-ray emission. This emerging dipolar region may have also triggered the filament eruption.

  16. An Automated Census Of Variable X-Ray Objects in the Direction of Clusters of Galaxies

    Science.gov (United States)

    MacIntosh, Lupe; Cunningham, Elizabeth; Ulmer, Melville P.

    2017-01-01

    Since the launch of the Chandra X-ray Observatory in 1999, broad x-ray surveys have been the primary means of discovering new objects in the sky. We present the results of one such survey, examining variable x-ray sources in archival Chandra data. Our survey maximizes the possibility of finding novel and interesting sources by searching for all x-ray variable sources and manually categorizing variable objects. This allows for the identification of interesting objects with common classifications, like a typical galaxy with unusual fluctuations. To further increase the probability of finding sources we focused on galaxy clusters, allowing us to look at over a thousand galaxies per observation. Our analysis was based on a previously compiled database of source fluxes, over all available observations and across energies from 0.2 keV to 12 keV. We converted the soft x-ray flux (0.5 to 2 keV) to count rate, then fit it to the average count rate using least squares regression. Variable sources are defined as those with c2 > 50 over the total observed time. We then categorized variable objects and found optical counterparts. Our criteria identified 49 variable sources from a total of 58,000 sources in our database, though we estimate up to 20% of the database is extraneous double sources. Of these variable sources, 9 had not been previously identified in the SIMBAD database and 28 had not been previously categorized as variable. A majority of the objects found were expected, such as various classes of active galactic nuclei and variable red dwarfs. Other more interesting objects include a variable A-type star and an ultraluminous galaxy.

  17. X-ray laser measurements of direct drive imprint on vulcan

    Energy Technology Data Exchange (ETDEWEB)

    Kalantar, D.H.; Wolfrum, E.; Zhang, J. [and others

    1997-07-01

    High gain direct drive inertial confinement fusion requires very uniform irradiation of a hollow spherical shell with a layer of fusionable deuterium and tritium on its inner surface. The intensity of laser irradiation builds up in several nanoseconds from an initial `foot` at {approximately}10{sup 13} W/cm{sup 2} to more than 10{sup 15} W/cm{sup 2} during the main drive pulse. Laser ablation of the capsule surface produces a high pressure, accelerating the shell radially inward, and resulting in Rayleigh-Taylor (R-T) growth of surface perturbations originating from both the initial surface roughness of the capsule and from imprint of spatial non- uniformities in the laser drive intensity early in the laser pulse. The uniformity of illumination on a direct drive implosion capsule is determined on a large scale by the multi-beam irradiation geometry, and on a small scale by beam smoothing techniques. By using a large number of beams (such as the 60 beams of the Omega laser or 48 beam clusters for the NIF), large scale non-uniformities due to the overlap of the laser focal spots are adequately reduced. Random phase plates (RPPs) are introduced to smooth the individual beam focal spots. The spatial intensity variations of the individual beam speckle patterns may be smoothed by spectral dispersion (SD) with induced spatial incoherence (ISI) or by using partially coherent light. We performed experiments to study the imprint under conditions simulating the low intensity foot of the pulse on an ignition target, such as designed for the NIF. We used a 0.53 micrometer laser wavelength, and considered the imprint in thin Al foils due to both a broadband distribution of modes such as those in smoothed speckle patterns, and a single mode optical intensity variation. We characterized the laser imprint using a Ge x-ray laser and multilayer imaging optics, as described previously. In this paper we summarize and compare the multiple and single mode imprinting results. 9 refs., 7

  18. Diagnosing Direct-Drive, Shock-Heated, and Compressed Plastic Planar Foils with Noncollective Spectrally Resolved X-Ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Sawada, H.; Regan, S.P.; Meyerhofer, D.D.; Igumenshchev, I.V.; Goncharov, V.N.; Boehly, T.R.; Epstein, R.; Sangster, T.C.; Smalyuk, V.A.; Yaakobi, B.; Gregori, G.; Glenzer, S.H.; Landen, O.L.

    2007-12-14

    The electron temperature (Te) and average ionization (Z) of nearly Fermi-degenerate, direct-drive, shock-heated, and compressed plastic planar foils were investigated using noncollective spectrally resolved x-ray scattering on the OMEGA Laser System. Plastic (CH) and Br-doped CH foils were driven with six beams, having an overlapped intensity of ~1 × 10^14 W/cm^2 and generating ~15-Mbar pressure in the foil.

  19. Instability of Solution of Phase Retrieval in Direct Diffraction Phase-Contrast Imaging with Partially Coherent X-Ray Source

    Institute of Scientific and Technical Information of China (English)

    GUO Hua; HAN Shen-Sheng

    2006-01-01

    The theoretical model of direct diffraction phase-contrast imaging with partially coherent x-ray source is expressedby an operator of multiple integral. It is presented that the integral operator is linear. The problem of its phaseretrieval is described by solving an operator equation of multiple integral. It is demonstrated that the solution ofthe phase retrieval is unstable. The numerical simulation is performed and the result validates that the solutionof the phase retrieval is unstable.

  20. Abundance Constraints and Direct Redshift Measurement of the Diffuse X-ray Emission from a Distant Cluster of Galaxies

    CERN Document Server

    Hashimoto, Y; Böhringer, H; Fabian, A C; Hasinger, G; Mainieri, V; Brunner, H; Hashimoto, Yasuhiro; Barcons, Xavier; Boehringer, Hans; Fabian, Andrew C.; Hasinger, Guenther; Mainieri, Vincenzo; Brunner, Hermann

    2004-01-01

    We report on the XMM-Newton (XMM) observation of RXJ1053.7+5735, one of the most distant X-ray selected clusters of galaxies, which also shows an unusual double-lobed X-ray morphology, indicative of a possible equal-mass cluster merger. The cluster was discovered during the ROSAT deep pointings in the direction of the Lockman Hole. All XMM Lockman Hole observations (PV, AO-1 & AO-2 phases) with the European Photon Imaging Camera (EPIC) were combined for the analysis, totaling exposure times ~ 648 ks, 738 ks, and 758 ks for pn, MOS1, and MOS2, respectively. With this 'deep' dataset, we could detect the Fe K line and obtain a strong constraint on cluster metallicity, which is difficult to achieve for clusters at z > 1. The best-fit abundance is 0.46 +0.11/-0.07 times the solar value. The Fe line emission also allows us to directly estimate the redshift of diffuse gas, with a value z = 1.14 +0.01/-0.01. This is one of the first clusters whose X-ray redshift is directly measured prior to the secure knowledge ...

  1. The direct cooling tail method for X-ray burst analysis to constrain neutron star masses and radii

    Science.gov (United States)

    Suleimanov, Valery F.; Poutanen, Juri; Nättilä, Joonas; Kajava, Jari J. E.; Revnivtsev, Mikhail G.; Werner, Klaus

    2017-04-01

    Determining neutron star (NS) radii and masses can help to understand the properties of matter at supra-nuclear densities. Thermal emission during thermonuclear X-ray bursts from NSs in low-mass X-ray binaries provides a unique opportunity to study NS parameters, because of the high fluxes, large luminosity variations and the related changes in the spectral properties. The standard cooling tail method uses hot NS atmosphere models to convert the observed spectral evolution during cooling stages of X-ray bursts to the Eddington flux FEdd and the stellar angular size Ω. These are then translated to the constraints on the NS mass M and radius R. Here we present the improved, direct cooling tail method that generalizes the standard approach. First, we adjust the cooling tail method to account for the bolometric correction to the flux. Then, we fit the observed dependence of the blackbody normalization on flux with a theoretical model directly on the M-R plane by interpolating theoretical dependences to a given gravity, hence ensuring only weakly informative priors for M and R instead of FEdd and Ω. The direct cooling method is demonstrated using a photospheric radius expansion burst from SAX J1810.8-2609, which has happened when the system was in the hard state. Comparing to the standard cooling tail method, the confidence regions are shifted by 1σ towards larger radii, giving R = 11.5-13.0 km at M = 1.3-1.8 M⊙ for this NS.

  2. X-ray holography with atomic resolution

    Science.gov (United States)

    Tegze, Miklós; Faigel, Gyula

    1996-03-01

    DIFFRACTION methods for crystallographic structure determination suffer from the so-called 'phase problem'; a diffraction pattern provides intensity but not phase information for the scattered beams, and therefore cannot be uniquely inverted to obtain the crystal structure of a sample. Holographic methods1, on the other hand, offer a means of extracting both intensity and phase information. To be useful for crystallographic applications, holography must be implemented with radiation of sufficiently small wavelength to resolve atomic-scale features2. One method, electron-emission holography3-9, uses electron waves and is a powerful tool for studying surface structure; but it cannot image the internal structure of solids because of complications arising from the highly anisotropic nature of electron scattering processes. A proposed alternative method uses X-rays2,10-13, which scatter more isotropically than electrons. Here we demonstrate the efficacy of atomic-scale X-ray holography by obtaining direct images of the three-dimensional arrangement of strontium atoms in the cubic perovskite SrTiO3. With more intense synchrotron sources for illumination, and with the development of improved X-ray detectors, X-ray holography should become a powerful general technique for unambiguous structure determination in condensed matter systems.

  3. X-ray self-emission imaging used to diagnose 3-D nonuniformities in direct-drive ICF implosions

    Science.gov (United States)

    Davis, A. K.; Michel, D. T.; Craxton, R. S.; Epstein, R.; Hohenberger, M.; Mo, T.; Froula, D. H.

    2016-11-01

    As hydrodynamics codes develop to increase understanding of three-dimensional (3-D) effects in inertial confinement fusion implosions, diagnostics must adapt to evaluate their predictive accuracy. A 3-D radiation postprocessor was developed to investigate the use of soft x-ray self-emission images of an imploding target to measure the size of nonuniformities on the target surface. Synthetic self-emission images calculated from 3-D simulations showed a narrow ring of emission outside the ablation surface of the target. Nonuniformities growing in directions perpendicular to the diagnostic axis were measured through angular variations in the radius of the steepest intensity gradient on the inside of the ring and through changes in the peak x-ray intensity in the ring as a function of angle. The technique was applied to an implosion to measure large 3-D nonuniformities resulting from two dropped laser beam quads at the National Ignition Facility.

  4. Directly Characterizing the Relative Strength and Momentum Dependence of Electron-Phonon Coupling Using Resonant Inelastic X-Ray Scattering

    Science.gov (United States)

    Devereaux, T. P.; Shvaika, A. M.; Wu, K.; Wohlfeld, K.; Jia, C. J.; Wang, Y.; Moritz, B.; Chaix, L.; Lee, W.-S.; Shen, Z.-X.; Ghiringhelli, G.; Braicovich, L.

    2016-10-01

    The coupling between lattice and charge degrees of freedom in condensed matter materials is ubiquitous and can often result in interesting properties and ordered phases, including conventional superconductivity, charge-density wave order, and metal-insulator transitions. Angle-resolved photoemission spectroscopy and both neutron and nonresonant x-ray scattering serve as effective probes for determining the behavior of appropriate, individual degrees of freedom—the electronic structure and lattice excitation, or phonon dispersion, respectively. However, each provides less direct information about the mutual coupling between the degrees of freedom, usually through self-energy effects, which tend to renormalize and broaden spectral features precisely where the coupling is strong, impacting one's ability to quantitatively characterize the coupling. Here, we demonstrate that resonant inelastic x-ray scattering, or RIXS, can be an effective tool to directly determine the relative strength and momentum dependence of the electron-phonon coupling in condensed matter systems. Using a diagrammatic approach for an eight-band model of copper oxides, we study the contributions from the lowest-order diagrams to the full RIXS intensity for a realistic scattering geometry, accounting for matrix element effects in the scattering cross section, as well as the momentum dependence of the electron-phonon coupling vertex. A detailed examination of these maps offers a unique perspective into the characteristics of electron-phonon coupling, which complements both neutron and nonresonant x-ray scattering, as well as Raman and infrared conductivity.

  5. Directly Characterizing the Relative Strength and Momentum Dependence of Electron-Phonon Coupling Using Resonant Inelastic X-Ray Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Devereaux, T.P.; Shvaika, A.M.; Wu, K.; Wohlfeld, K.; Jia, C.J.; Wang, Y.; Moritz, B.; Chaix, L.; Lee, W.-S.; Shen, Z.-X.; Ghiringhelli, G.; Braicovich, L.

    2016-10-25

    The coupling between lattice and charge degrees of freedom in condensed matter materials is ubiquitous and can often result in interesting properties and ordered phases, including conventional superconductivity, charge-density wave order, and metal-insulator transitions. Angle-resolved photoemission spectroscopy and both neutron and nonresonant x-ray scattering serve as effective probes for determining the behavior of appropriate, individual degrees of freedom—the electronic structure and lattice excitation, or phonon dispersion, respectively. However, each provides less direct information about the mutual coupling between the degrees of freedom, usually through self-energy effects, which tend to renormalize and broaden spectral features precisely where the coupling is strong, impacting one’s ability to quantitatively characterize the coupling. Here, we demonstrate that resonant inelastic x-ray scattering, or RIXS, can be an effective tool to directly determine the relative strength and momentum dependence of the electron-phonon coupling in condensed matter systems. Using a diagrammatic approach for an eight-band model of copper oxides, we study the contributions from the lowest-order diagrams to the full RIXS intensity for a realistic scattering geometry, accounting for matrix element effects in the scattering cross section, as well as the momentum dependence of the electron-phonon coupling vertex. A detailed examination of these maps offers a unique perspective into the characteristics of electron-phonon coupling, which complements both neutron and nonresonant x-ray scattering, as well as Raman and infrared conductivity.

  6. The direct cooling tail method for X-ray burst analysis to constrain neutron star masses and radii

    CERN Document Server

    Suleimanov, Valery F; Nättilä, Joonas; Kajava, Jari J E; Revnivtsev, Mikhail G; Werner, Klaus

    2016-01-01

    Determining neutron star (NS) radii and masses can help to understand the properties of matter at supra-nuclear densities. Thermal emission during thermonuclear X-ray bursts from NSs in low-mass X-ray binaries provides a unique opportunity to study NS parameters, because of the high fluxes, large luminosity variations and the related changes in the spectral properties. The standard cooling tail method uses hot NS atmosphere models to convert the observed spectral evolution during cooling stages of X-ray bursts to the Eddington flux F_Edd and the stellar angular size \\Omega. These are then translated to the constraints on the NS mass M and radius R. Here we present the improved, direct cooling tail method that generalises the standard approach. First, we adjust the cooling tail method to account for the bolometric correction to the flux. Then, we fit the observed dependence of the blackbody normalization on flux with a theoretical model directly on the M-R plane by interpolating theoretical dependences to a gi...

  7. Rapid prototyping of Fresnel zone plates via direct Ga(+) ion beam lithography for high-resolution X-ray imaging.

    Science.gov (United States)

    Keskinbora, Kahraman; Grévent, Corinne; Eigenthaler, Ulrike; Weigand, Markus; Schütz, Gisela

    2013-11-26

    A significant challenge to the wide utilization of X-ray microscopy lies in the difficulty in fabricating adequate high-resolution optics. To date, electron beam lithography has been the dominant technique for the fabrication of diffractive focusing optics called Fresnel zone plates (FZP), even though this preparation method is usually very complicated and is composed of many fabrication steps. In this work, we demonstrate an alternative method that allows the direct, simple, and fast fabrication of FZPs using focused Ga(+) beam lithography practically, in a single step. This method enabled us to prepare a high-resolution FZP in less than 13 min. The performance of the FZP was evaluated in a scanning transmission soft X-ray microscope where nanostructures as small as sub-29 nm in width were clearly resolved, with an ultimate cutoff resolution of 24.25 nm, demonstrating the highest first-order resolution for any FZP fabricated by the ion beam lithography technique. This rapid and simple fabrication scheme illustrates the capabilities and the potential of direct ion beam lithography (IBL) and is expected to increase the accessibility of high-resolution optics to a wider community of researchers working on soft X-ray and extreme ultraviolet microscopy using synchrotron radiation and advanced laboratory sources.

  8. Direct Polishing of Full-Shell, High-Resolution X-Ray Optics

    Science.gov (United States)

    Roche, Jacqueline M.; Gubarev, Mikhail V.; Smith, W. Scott; O'Dell, Stephen L.; Kolodziejczak, Jeffrey J.; Weisskopf, Martin C.; Ramsey, Brian D.; Elsner, Ronald F.

    2014-01-01

    Future x-ray telescopes will likely require lightweight mirrors to attain the large collecting areas needed to accomplish the science objectives. Understanding and demonstrating processes now is critical to achieving sub-arcsecond performance in the future. Consequently, designs not only of the mirrors but of fixtures for supporting them during fabrication, metrology, handling, assembly, and testing must be adequately modeled and verified. To this end, MSFC is using finite-element modeling to study the effects of mounting on thin, full-shell grazing-incidence mirrors, during all processes leading to a flight.

  9. Structural and electrical properties of polycrystalline CdTe films for direct X-ray imaging detectors

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Bo Kyung, E-mail: goldrain99@kaist.ac.kr [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan, Repulic of Korea (Korea, Republic of); Yang, Keedong [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan, Repulic of Korea (Korea, Republic of); Cha, Eun Seok; Yong, Seok-Min [Department of Materials Science and Engineering, KAIST, Daejeon, Repulic of Korea (Korea, Republic of); Heo, Duchang; Kim, Ryun Kyung; Jeon, Seongchae; Seo, Chang-Woo; Kim, Cho Rong [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan, Repulic of Korea (Korea, Republic of); Ahn, Byung Tae [Department of Materials Science and Engineering, KAIST, Daejeon, Repulic of Korea (Korea, Republic of); Lee, Tae-Bum [Advanced Medical Device Research Center, Korea Electrotechnology Research Institute, Ansan, Repulic of Korea (Korea, Republic of)

    2013-12-11

    We introduce polycrystalline cadmium telluride (CdTe) with high atomic number and density, low effective energy and wide band gap for application in large area diagnostic X-ray digital imaging. In this work, polycrystalline CdTe films were fabricated on ITO/glass substrate by both physical vapor deposition (PVD) with slow deposition rate and pressure of 10{sup −6} Torr and the closed space sublimation (CSS) method with high deposition rate and low vacuum pressure(10{sup −2} Torr). The various polycrystalline CdTe films were grown at different deposition rates and substrate temperatures. Physical properties such as microstructures and the crystal structure of the polycrystalline samples were investigated by SEM and XRD patterns respectively. The PVD method resulted in microstructures with columnar shape and more uniform surface, while the CSS method produced microstructures with many larger grains and less uniform surface. The films were polycrystalline structures with a preferential (111) direction. The electrical and optical properties such as the dark current as a function of applied bias voltage and X-ray sensitivity of the fabricated films were measured and investigated under X-ray exposure.

  10. Structural and electrical properties of polycrystalline CdTe films for direct X-ray imaging detectors

    Science.gov (United States)

    Cha, Bo Kyung; Yang, Keedong; Cha, Eun Seok; Yong, Seok-Min; Heo, Duchang; Kim, Ryun Kyung; Jeon, Seongchae; Seo, Chang-Woo; Kim, Cho Rong; Ahn, Byung Tae; Lee, Tae-Bum

    2013-12-01

    We introduce polycrystalline cadmium telluride (CdTe) with high atomic number and density, low effective energy and wide band gap for application in large area diagnostic X-ray digital imaging. In this work, polycrystalline CdTe films were fabricated on ITO/glass substrate by both physical vapor deposition (PVD) with slow deposition rate and pressure of 10-6 Torr and the closed space sublimation (CSS) method with high deposition rate and low vacuum pressure(10-2 Torr). The various polycrystalline CdTe films were grown at different deposition rates and substrate temperatures. Physical properties such as microstructures and the crystal structure of the polycrystalline samples were investigated by SEM and XRD patterns respectively. The PVD method resulted in microstructures with columnar shape and more uniform surface, while the CSS method produced microstructures with many larger grains and less uniform surface. The films were polycrystalline structures with a preferential (111) direction. The electrical and optical properties such as the dark current as a function of applied bias voltage and X-ray sensitivity of the fabricated films were measured and investigated under X-ray exposure.

  11. Measurement of illite particle thickness using a direct Fourier transform of small-angle X-ray scattering data

    Science.gov (United States)

    Shang, C.; Rice, J.A.; Eberl, D.D.; Lin, S.-J.

    2003-01-01

    It has been suggested that interstratified illite-smectite (I-S) minerals are composed of aggregates of fundamental particles. Many attempts have been made to measure the thickness of such fundamental particles, but each of the methods used suffers from its own limitations and uncertainties. Small-angle X-ray scattering (SAXS) can be used to measure the thickness of particles that scatter X-rays coherently. We used SAXS to study suspensions of Na-rectorite and other illites with varying proportions of smectite. The scattering intensity (I) was recorded as a function of the scattering vector, q = (4 ??/??) sin(??/2), where ?? is the X-ray wavelength and ?? is the scattering angle. The experimental data were treated with a direct Fourier transform to obtain the pair distance distribution function (PDDF) that was then used to determine the thickness of illite particles. The Guinier and Porod extrapolation were used to obtain the scattering intensity beyond the experimental q, and the effects of such extrapolations on the PDDF were examined. The thickness of independent rectorite particles (used as a reference mineral) is 18.3 A??. The SAXS results are compared with those obtained by X-ray diffraction peak broadening methods. It was found that the power-law exponent (??) obtained by fitting the data in the region of q = 0.1 -0.6 nm-1 to the power law (I = Ioq-??) is a linear function of illite particle thickness. Therefore, illite particle thickness could be predicted by the linear relationship as long as the thickness is within the limit where ?? <4.0.

  12. Direct X-ray radiogrammetry versus dual-energy X-ray absorptiometry: assessment of bone density in children treated for acute lymphoblastic leukaemia and growth hormone deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Rijn, Rick R. van; Wittenberg, Rianne [Academic Medical Centre Amsterdam, Department of Radiology, Amsterdam Zuid-Oost (Netherlands); Boot, Annemieke; Sluis, Inge M. van der; MuinckKeizer-Schrama, Sabine M.P.F. de [Erasmus MC-Sophia Children' s Hospital, Department of Paediatric Endocrinology, Rotterdam (Netherlands); Heuvel-Eibrink, Marry M. van den [Erasmus MC-Sophia Children' s Hospital, Department of Paediatric Haematology/Oncology, Rotterdam (Netherlands); Lequin, Maarten H. [Erasmus MC-Sophia Children' s Hospital, Department of Paediatric Radiology, Rotterdam (Netherlands); Kuijk, Cornelis Van [University Medical Centre ' Radboud' , Department of Radiology, Nijmegen (Netherlands)

    2006-03-15

    In recent years interest in bone densitometry in children has increased. To evaluate the clinical application of digital X-ray radiogrammetry (DXR) and compare the results with those of dual-energy X-ray absorptiometry (DXA). A total of 41 children with acute lymphoblastic leukaemia (ALL) and 26 children with growth hormone deficiency (GHD) were included in this longitudinal study. Radiographs of the left hand were obtained and used for DXR. DXA of the total body and of the lumbar spine was performed. In both study populations significant correlations between DXR and DXA were found, and, with the exception of the correlation between DXR bone mineral density (DXR-BMD) and bone mineral apparent density in the GHD population, all correlations had a P-value of <0.001. During treatment a change in DXR-BMD was found in children with GHD. Our study showed that DXR in a paediatric population shows a strong correlation with DXA of the lumbar spine and total body and that it is able to detect a change in BMD during treatment. (orig.)

  13. An accelerated direct demodulation method for image reconstruction using spherical data from the hard X-ray modulation telescope

    Institute of Scientific and Technical Information of China (English)

    Zhuo-Xi Huo; Jian-Feng Zhou

    2013-01-01

    The hard X-ray modulation telescope (HXMT) mission is mainly devoted to performing an all-sky survey at 1-250 keV with both high sensitivity and high spatial resolution.The observed data reduction as well as the image reconstruction for HXMT can be achieved by using the direct demodulation method (DDM).However the original DDM is too computationally expensive for multi-dimensional data with high resolution to be employed for HXMT data.We propose an accelerated direct demodulation method especially adapted for data from HXMT.Simulations are also presented to demonstrate this method.

  14. Skull x-ray

    Science.gov (United States)

    X-ray - head; X-ray - skull; Skull radiography; Head x-ray ... There is low radiation exposure. X-rays are monitored and regulated to provide the minimum amount of radiation exposure needed to produce the image. Most ...

  15. Neck x-ray

    Science.gov (United States)

    X-ray - neck; Cervical spine x-ray; Lateral neck x-ray ... There is low radiation exposure. X-rays are monitored so that the lowest amount of radiation is used to produce the image. Pregnant women and ...

  16. Phase contrast X-ray microtomography of the Rhodnius prolixus head: Comparison of direct reconstruction and phase retrieval approach

    Science.gov (United States)

    Almeida, A. P.; Braz, D.; Nogueira, L. P.; Colaço, M. V.; Soares, J.; Cardoso, S. C.; Garcia, E. S.; Azambuja, P.; Gonzalez, M. S.; Mohammadi, S.; Tromba, G.; Barroso, R. C.

    2014-02-01

    We have used phase-contrast X-ray microtomography (PPC-μCT) to study the head of the blood-feeding bug, Rhodnius prolixus, which is one of the most important insect vector of Trypanosoma cruzi, ethiologic agent of Chagas disease in Latin America. Images reconstructed from phase-retrieved projections processed by ANKA phase are compared to those obtained through direct tomographic reconstruction of the flat-field-corrected transmission radiographs. It should be noted that the relative locations of the important morphological internal structures are observable with a precision that is difficult to obtain without the phase retrieval approach.

  17. Determining the directional strain shift coefficients for tensile Ge: a combined x-ray diffraction and Raman spectroscopy study

    Science.gov (United States)

    Etzelstorfer, Tanja; Wyss, Andreas; Süess, Martin J.; Schlich, Franziska F.; Geiger, Richard; Frigerio, Jacopo; Stangl, Julian

    2017-02-01

    In this work the calibration of the directional Raman strain shift coefficient for tensile strained Ge microstructures is reported. The strain shift coefficient is retrieved from micro-Raman spectroscopy measurements in combination with absolute strain measurements from x-ray diffraction using focused synchrotron radiation. The results are used to fit the phonon deformation potentials. A linear dependence of the phonon deformation potentials p and q is revealed. The method can be extended to provide strain calibration of Raman experiments also in other material system.

  18. Green direct determination of mineral elements in artichokes by infrared spectroscopy and X-ray fluorescence.

    Science.gov (United States)

    Mir-Marqués, Alba; Martínez-García, Maria; Garrigues, Salvador; Cervera, M Luisa; de la Guardia, Miguel

    2016-04-01

    Near infrared (NIR) and X-ray fluorescence (XRF) spectroscopy were investigated to predict the concentration of calcium, potassium, iron, magnesium, manganese and zinc in artichoke samples. Sixty artichokes were purchased from different Spanish areas (Benicarló, Valencia and Murcia). NIR and XRF spectra, combined with partial least squares (PLS) data treatment, were used to develop chemometric models for the prediction of mineral concentration. To obtain reference data, samples were mineralised and analysed by inductively coupled plasma optical emission spectrometry (ICP-OES). Coefficients of determination obtained for the regression between predicted values and reference ones for calcium, potassium, magnesium, iron, manganese and zinc were 0.61, 0.79, 0.53, 0.77, 0.54 and 0.60 for NIR and 0.96, 0.93, 0.80, 0.79, 0.76 and 0.90 for XRF, respectively. Both assayed methodologies, offer green alternatives to classical mineral analysis, but XRF provided the best results in order to be used as a quantitative screening method.

  19. Direct hot slumping and accurate integration process to manufacture prototypal x-ray optical units made of glass

    Science.gov (United States)

    Civitani, M.; Ghigo, M.; Basso, S.; Proserpio, L.; Spiga, D.; Salmaso, B.; Pareschi, G.; Tagliaferri, G.; Burwitz, V.; Hartner, G.; Menz, B.; Bavdaz, M.; Wille, E.

    2013-09-01

    X-ray telescopes with very large collecting area, like the proposed International X-ray Observatory (IXO, with around 3 m2 at 1 keV), need to be composed of a large number high quality mirror segments, aiming at achieving an angular resolution better than 5 arcsec HEW (Half-Energy-Width). A possible technology to manufacture the modular elements that will compose the entire optical module, named X-ray Optical Units (XOUs), consists of stacking in Wolter-I configuration several layers of thin foils of borosilicate glass, previously formed by hot slumping. The XOUs are subsequently assembled to form complete multi-shell optics with Wolter-I geometry. The achievable global angular resolution of the optic relies on the required surface shape accuracy of slumped foils, on the smoothness of the mirror surfaces and on the correct integration and co-alignment of the mirror segments. The Brera Astronomical Observatory (INAF-OAB) is leading a study, supported by ESA, concerning the implementation of the IXO telescopes based on thin slumped glass foils. In addition to the opto-mechanical design, the study foresees the development of a direct hot slumping thin glass foils production technology. Moreover, an innovative assembly concept making use of Wolter-I counter-form moulds and glass reinforcing ribs is under development. The ribs connect pairs of consecutive foils in an XOU stack, playing a structural and a functional role. In fact, as the ribs constrain the foil profile to the correct shape during the bonding, they damp the low-frequency profile errors still present on the foil after slumping. A dedicated semirobotic Integration MAchine (IMA) has been realized to this scope and used to build a few integrated prototypes made of several layers of slumped plates. In this paper we provide an overview of the project, we report the results achieved so far, including full illumination intra-focus X-ray tests of the last integrated prototype that are compliant with a HEW of

  20. Songlines from Direct Collapse Seed Black Holes: Effects of X-rays on Black Hole Growth and Stellar Populations

    CERN Document Server

    Aykutalp, Aycin; Spaans, Marco; Meijerink, Rowin

    2014-01-01

    In the last decade, the growth of supermassive black holes (SMBHs) has been intricately linked to galaxy formation and evolution and is a key ingredient in the assembly of galaxies. To investigate the origin of SMBHs, we perform cosmological simulations that target the direct collapse black hole (DCBH) seed formation scenario in the presence of two different strong Lyman-Werner (LW) background fields. These simulations include the X-ray irradiation from a central massive black hole (MBH), $\\rm{H}_2$ self-shielding and stellar feedback from metal-free and metal-enriched stars. We find in both simulations that local X-ray feedback induces metal-free star formation $\\sim 0.5$ Myr after the MBH forms. The MBH accretion rate reaches a maximum of $10^{-3}$ $M_{\\odot}$ yr$^{-1}$ in both simulations. However, the duty cycle differs which is derived to be $6\\%$ and $50\\%$ for high and low LW cases, respectively. The MBH in the high LW case grows only $\\sim 6\\%$ in 100 Myr compared to $16\\%$ in the low LW case. We find...

  1. Songlines from Direct Collapse Seed Black Holes: Effects of X-Rays on Black Hole Growth and Stellar Populations

    Science.gov (United States)

    Aykutalp, Aycin; Wise, John H.; Spaans, Marco; Meijerink, Rowin

    2014-12-01

    In the last decade, the growth of supermassive black holes (SMBHs) has been intricately linked to galaxy formation and evolution and is a key ingredient in the assembly of galaxies. To investigate the origin of SMBHs, we perform cosmological simulations that target the direct collapse black hole seed formation scenario in the presence of two different strong Lyman-Werner (LW) background fields. These simulations include the X-ray irradiation from a central massive black hole (MBH), H2 self-shielding, and stellar feedback from metal-free and metal-enriched stars. We find in both simulations that local X-ray feedback induces metal-free star formation ~0.5 Myr after the MBH forms. The MBH accretion rate reaches a maximum of 10-3 M ⊙ yr-1 in both simulations. However, the duty cycle differs and is derived to be 6% and 50% for the high and low LW cases, respectively. The MBH in the high LW case grows only ~6% in 100 Myr compared to 16% in the low LW case. We find that the maximum accretion rate is determined by the local gas thermodynamics, whereas the duty cycle is determined by the large-scale gas dynamics and gas reservoir. We conclude that radiative feedback from the central MBH plays an important role in star formation in the nuclear regions and stifling initial MBH growth relative to the typical Eddington rate argument, and that initial MBH growth might be affected by the local LW radiation field.

  2. Single shot x-ray phase contrast imaging using a direct conversion microstrip detector with single photon sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Kagias, M.; Cartier, S.; Wang, Z.; Stampanoni, M. [Swiss Light Source, Paul Scherrer Institute, 5232 Villigen (Switzerland); Institute for Biomedical Engineering, University and ETH Zurich, 8092 Zurich (Switzerland); Bergamaschi, A.; Dinapoli, R.; Mozzanica, A.; Schmitt, B. [Swiss Light Source, Paul Scherrer Institute, 5232 Villigen (Switzerland)

    2016-06-06

    X-ray phase contrast imaging enables the measurement of the electron density of a sample with high sensitivity compared to the conventional absorption contrast. This is advantageous for the study of dose-sensitive samples, in particular, for biological and medical investigations. Recent developments relaxed the requirement for the beam coherence, such that conventional X-ray sources can be used for phase contrast imaging and thus clinical applications become possible. One of the prominent phase contrast imaging methods, Talbot-Lau grating interferometry, is limited by the manufacturing, alignment, and photon absorption of the analyzer grating, which is placed in the beam path in front of the detector. We propose an alternative improved method based on direct conversion charge integrating detectors, which enables a grating interferometer to be operated without an analyzer grating. Algorithms are introduced, which resolve interference fringes with a periodicity of 4.7 μm recorded with a 25 μm pitch Si microstrip detector (GOTTHARD). The feasibility of the proposed approach is demonstrated by an experiment at the TOMCAT beamline of the Swiss Light Source on a polyethylene sample.

  3. Direct measurements of multi-photon induced nonlinear lattice dynamics in semiconductors via time-resolved x-ray scattering

    Science.gov (United States)

    Williams, G. Jackson; Lee, Sooheyong; Walko, Donald A.; Watson, Michael A.; Jo, Wonhuyk; Lee, Dong Ryeol; Landahl, Eric C.

    2016-12-01

    Nonlinear optical phenomena in semiconductors present several fundamental problems in modern optics that are of great importance for the development of optoelectronic devices. In particular, the details of photo-induced lattice dynamics at early time-scales prior to carrier recombination remain poorly understood. We demonstrate the first integrated measurements of both optical and structural, material-dependent quantities while also inferring the bulk impulsive strain profile by using high spatial-resolution time-resolved x-ray scattering (TRXS) on bulk crystalline gallium arsenide. Our findings reveal distinctive laser-fluence dependent crystal lattice responses, which are not described by previous TRXS experiments or models. The initial linear expansion of the crystal upon laser excitation stagnates at a laser fluence corresponding to the saturation of the free carrier density before resuming expansion in a third regime at higher fluences where two-photon absorption becomes dominant. Our interpretations of the lattice dynamics as nonlinear optical effects are confirmed by numerical simulations and by additional measurements in an n-type semiconductor that allows higher-order nonlinear optical processes to be directly observed as modulations of x-ray diffraction lineshapes.

  4. X-ray Fluorescence Sectioning

    CERN Document Server

    Cong, Wenxiang

    2012-01-01

    In this paper, we propose an x-ray fluorescence imaging system for elemental analysis. The key idea is what we call "x-ray fluorescence sectioning". Specifically, a slit collimator in front of an x-ray tube is used to shape x-rays into a fan-beam to illuminate a planar section of an object. Then, relevant elements such as gold nanoparticles on the fan-beam plane are excited to generate x-ray fluorescence signals. One or more 2D spectral detectors are placed to face the fan-beam plane and directly measure x-ray fluorescence data. Detector elements are so collimated that each element only sees a unique area element on the fan-beam plane and records the x-ray fluorescence signal accordingly. The measured 2D x-ray fluorescence data can be refined in reference to the attenuation characteristics of the object and the divergence of the beam for accurate elemental mapping. This x-ray fluorescence sectioning system promises fast fluorescence tomographic imaging without a complex inverse procedure. The design can be ad...

  5. Micromechanical Time-Lapse X-ray CT Study of Fatigue Damage in Uni-Directional Fibre Composites

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Lowe, Tristan; Withers, Philip J.

    2015-01-01

    This study considers fatigue damage evolution in a uni-directional (UD) glass fibre composite used for wind turbine blades which is manufactured from a non-crimp fabric. It is the initial part of a time-lapse study where the damage progression is followed in a sample during a fatigue test....... In the current study 3D X-ray Computed Tomography (XCT) is used to characterise the fatigue damage in the material at three different stages of the fatigue life of a tension-tension fatigue test. 3D XCT is performed on rectangular samples (4x4x110mm) cut out from pre-fatigued full-size fatigue test specimens...

  6. Effect of Oxide Level on Pore Formation in A356 Alloy by X-Ray Imaging and Directional Solidification Technology

    Science.gov (United States)

    Liao, Hengcheng; Song, Wan; Wang, Qigui; Zhao, Lei; Fan, Ran

    Effect of oxide level on porosity formation in an A356 alloy was investigated using micro-focus X-ray imaging and directional solidification technology. The increase of oxide level in liquid aluminum was achieved by violently stirring molten metal at elevated temperature. During solidification, the increased oxide content in melt significantly increases the amount of active nucleation sites for porosity and thus raises the nucleation temperature of pores. The fast growth of those early formed pores further restrains the succeeding nucleation operations of new pores in local regions and results in a considerable reduction in pore density. It was also found that the melt with high oxide content shows less dependency of growth rate reduction with local temperature.

  7. Chest X Ray?

    Science.gov (United States)

    ... this page from the NHLBI on Twitter. Chest X Ray A chest x ray is a fast and painless imaging test ... tissue scarring, called fibrosis. Doctors may use chest x rays to see how well certain treatments are ...

  8. X-Rays

    Science.gov (United States)

    X-rays are a type of radiation called electromagnetic waves. X-ray imaging creates pictures of the inside of ... different amounts of radiation. Calcium in bones absorbs x-rays the most, so bones look white. Fat ...

  9. Medical X-Rays

    Science.gov (United States)

    ... Benefits The discovery of X-rays and the invention of CT represented major advances in medicine. X- ... in X-ray and CT Examinations — X-ray definition, dose measurement, safety precautions, risk, and consideration with ...

  10. Direct Characterization of Kerogen By X-Ray And Solid-State **13C Nuclear Magnetic Resonance Methods

    Energy Technology Data Exchange (ETDEWEB)

    Keleman, S.R.; Afeworki, M.; Gorbaty, M.L.; Sansone, M.; Kwiatek, P.J.; Walters, C.C.; Freund, H.; Siskin, M.; Bence, A.E.; Curry, D.J.; Solum, M.; Pugmire, R.J.; Vandenbroucke, M.; Leblond, M.; Behar, F.

    2007-07-09

    and S-XANES results indicate that the relative level of aromatic sulfur increases with an increasing amount of aromatic carbon for all kerogens. XPS show that the majority of nitrogen exists as pyrrolic forms in comparable relative abundances in all kerogens studied. The direct characterization results using X-ray and NMR methods for nitrogen, sulfur, oxygen, and carbon chemical structures provide a basis for developing both specific and general average chemical structural models for different organic matter type kerogens.

  11. Direct Characterization of Kerogen by X-ray and Solid-State [superscript 13]C Nuclear Magnetic Resonance Methods

    Energy Technology Data Exchange (ETDEWEB)

    Kelemen, S. R.; Afeworki, M.; Gorbaty, M.L.; Sansone, M.; Kwiatek, P.J.; Walters, C.C.; Freund, H.; Siskin, M.; Bence, A.E.; Curry, D.J.; Solum, M.; Pugmire, R.J.; Vandenbroucke, M.; Leblond, M.; Behar, F. (ExxonMobil); (ExxonMobil); (IFP); (Utah)

    2008-06-12

    kerogens. XPS and S-XANES results indicate that the relative level of aromatic sulfur increases with an increasing amount of aromatic carbon for all kerogens. XPS show that the majority of nitrogen exists as pyrrolic forms in comparable relative abundances in all kerogens studied. The direct characterization results using X-ray and NMR methods for nitrogen, sulfur, oxygen, and carbon chemical structures provide a basis for developing both specific and general average chemical structural models for different organic matter type kerogens.

  12. Subfemtosecond X-ray Pulses Produced Directly by High Harmonic Generation

    Institute of Scientific and Technical Information of China (English)

    WANG Ying-Song; XU Zhi-Zhan

    2000-01-01

    The generation of subfemtosecond pulses in hydrogen-like atoms through high-harmonic generation by using superintense multicycle driver pulses is numerically investigated. It is shown that a single subfemtosecond pulse can be directly generated when the driver pulse is strong enough to deplete the neutral atoms within several optical cycles. The propagation effect is neglected during the numerical examinations.

  13. Application of x-ray direct methods to surface reconstructions: The solution of projected superstructures

    Science.gov (United States)

    Torrelles, X.; Rius, J.; Boscherini, F.; Heun, S.; Mueller, B. H.; Ferrer, S.; Alvarez, J.; Miravitlles, C.

    1998-02-01

    The projections of surface reconstructions are normally solved from the interatomic vectors found in two-dimensional Patterson maps computed with the intensities of the in-plane superstructure reflections. Since for difficult reconstructions this procedure is not trivial, an alternative automated one based on the ``direct methods'' sum function [Rius, Miravitlles, and Allmann, Acta Crystallogr. A52, 634 (1996)] is shown. It has been applied successfully to the known c(4×2) reconstruction of Ge(001) and to the so-far unresolved In0.04Ga0.96As (001) p(4×2) surface reconstruction. For this last system we propose a modification of one of the models previously proposed for GaAs(001) whose characteristic feature is the presence of dimers along the fourfold direction.

  14. The suppression of direct collapse black hole formation by soft X-ray irradiation

    CERN Document Server

    Inayoshi, Kohei

    2014-01-01

    The origins of supermassive black holes (SMBHs) in galactic nuclei is one of the major unsolved problems in astrophysics. One hypothesis is that they grew from >10^5 Msun black holes that formed in the `direct collapse' of massive gas clouds that have low concentrations of both metals and molecular hydrogen (H2). Such clouds could form in the early (z>10) Universe if pre-galactic gas is irradiated by H2-photodissociating, far-ultraviolet (FUV) light from a nearby star-forming galaxy. The key uncertainties with this scenario are (1) how strong the FUV flux must be to sufficiently suppress the H2 abundance to prevent fragmentation and ordinary star formation; and (2) whether the requisite conditions arise frequently enough in nature to account for the observed number density of SMBHs (luminous quasars) at high redshifts. In this work, we re-examine the critical FUV flux J_crit that is required to keep H2 photodissociated and lead to direct collapse. We show that J_crit could be much higher than previously belie...

  15. X-ray phase contrast imaging at MAMI

    Energy Technology Data Exchange (ETDEWEB)

    El-Ghazaly, M.; Backe, H.; Lauth, W.; Kube, G.; Kunz, P.; Sharafutdinov, A.; Weber, T. [Universitaet Mainz, Institut fuer Kernphysik, Mainz (Germany)

    2006-05-15

    Experiments have been performed to explore the potential of the low emittance 855 MeV electron beam of the Mainz Microtron MAMI for imaging with coherent X-rays. Transition radiation from a micro-focused electron beam traversing a foil stack served as X-ray source with good transverse coherence. Refraction contrast radiographs of low absorbing materials, in particular polymer strings with diameters between 30 and 450 {mu}m, were taken with a polychromatic transition radiation X-ray source with a spectral distribution in the energy range between 8 and about 40 keV. The electron beam spot size had standard deviation {sigma}{sub h}=(8.6{+-}0.1) {mu}m in the horizontal and {sigma}{sub v}=(7.5{+-}0.1) {mu}m in the vertical direction. X-ray films were used as detectors. The source-to-detector distance amounted to 11.4 m. The objects were placed in a distance of up to 6m from the X-ray film. Holograms of strings were taken with a beam spot size {sigma}{sub v}=(0.50{+-}0.05) {mu}m in vertical direction, and a monochromatic X-ray beam of 6keV energy. A good longitudinal coherence has been obtained by the (111) reflection of a flat silicon single crystal in Bragg geometry. It has been demonstrated that a direct exposure CCD chip with a pixel size of 13 x 13 {mu}m{sup 2} provides a highly efficient on-line detector. Contrast images can easily be generated with a complete elimination of all parasitic background. The on-line capability allows a minimization of the beam spot size by observing the smallest visible interference fringe spacings or the number of visible fringes. It has been demonstrated that X-ray films are also very useful detectors. The main advantage in comparison with the direct exposure CCD chip is the resolution. For the Structurix D3 (Agfa) X-ray film the standard deviation of the resolution was measured to be {sigma}{sub f}=(1.2{+-}0.4) {mu}m, which is about a factor of 6 better than for the direct exposure CCD chip. With the small effective X-ray spot size

  16. Direct evidence of Ni magnetic moment in TbNi{sub 2}Mn—X-ray magnetic circular dichroism

    Energy Technology Data Exchange (ETDEWEB)

    Yu, D.H., E-mail: dyu@ansto.gov.au [Bragg Institute, Australian Nuclear Science and Technology Organisation, Lucas Heights, Sydney, NSW 2234 (Australia); Huang, Meng-Jie [National Synchrotron Radiation Research Center, 101 Hsin-Ann Road, Hsinchu Science Park, Hsinchu 30076, Taiwan (China); Wang, J.L. [Bragg Institute, Australian Nuclear Science and Technology Organisation, Lucas Heights, Sydney, NSW 2234 (Australia); School of Physical, Environmental and Mathematical Sciences, University of New South Wales, Canberra at the Australian Defense Force Academy, Sydney, ACT 2600 (Australia); Institute for Superconductivity and Electronic Materials, University of Wollongong, Wollongong, NSW 2522 (Australia); Su, Hui-Chia; Lin, Hong-Ji; Chen, Chien-Te [National Synchrotron Radiation Research Center, 101 Hsin-Ann Road, Hsinchu Science Park, Hsinchu 30076, Taiwan (China); Campbell, S.J. [School of Physical, Environmental and Mathematical Sciences, University of New South Wales, Canberra at the Australian Defense Force Academy, Sydney, ACT 2600 (Australia)

    2014-12-15

    We have investigated the individual magnetic moments of Ni, Mn and Tb atoms in the intermetallic compound TbNi{sub 2}Mn in the Laves phase (magnetic phase transition temperature T{sub C} ∼131 K) by X-ray magnetic circular dichroism (XMCD) studies at 300 K, 80 K and 20 K. Analyses of the experimental results reveal that Ni atoms at 20 K in an applied magnetic field of 1 T carry an intrinsic magnetic moment of spin and orbital magnetic moment contributions 0.53±0.01 μ{sub B} and 0.05±0.01 μ{sub B}, respectively. These moment values are similar to those of the maximum saturated moment of Ni element. A very small magnetic moment of order <0.1 μ{sub B} has been measured for Mn. This suggests that Mn is antiferromagnetically ordered across the two nearly equally occupied sites of 16d and 8a. A magnetic moment of up to ∼0.3 μ{sub B} has been observed for the Tb atoms. Identification of a magnetic moment on the Ni atoms has provided further evidence for the mechanism of enhancement of the magnetic phase transition temperature in TbNi{sub 2}Mn compared with TbNi{sub 2} (T{sub C}∼37.5 K) and TbMn{sub 2} (T{sub C}∼54 K) due to rare earth–transition metal (R–T) and transition metal–transition metal (T–T) interactions. The behaviour of the X-ray magnetic circular dichroism spectra of TbNi{sub 2}Mn at 300 K, 80 K and 20 K – above and below the magnetic ordering temperature T{sub C} ∼131 K – is discussed. - Highlights: • We study the magnetic moment of TbNi{sub 2}Mn with XMCD. • We observe directly the Ni intrinsic magnetic moment in TbNi{sub 2}Mn. • We find that Mn ordered antiferromagnetically across the 16d and 8a sites. • We confirm the mechanism for increasing the magnetic phase transition temperature.

  17. Characterization of uranium bearing material using x-ray fluorescence and direct gamma-rays measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Mujaini, M., E-mail: madihah@uniten.edu.my; Chankow, N. [Faculty of Engineering, Chulalongkorn University Phyathai Rd., Wang Mai, Patumwan, Bangkok 10330 (Thailand); Yusoff, M. Z.; Hamid, N. A. [College of Engineering, Universiti Tenaga Nasional 43000 Kajang, Selangor (Malaysia)

    2016-01-22

    Uranium ore can be easily detected due to various gamma-ray energies emitted from uranium daughters particularly from {sup 238}U daughters such as {sup 214}Bi, {sup 214}Pb and {sup 226}Ra. After uranium is extracted from uranium ore, only low energy gamma-rays emitted from {sup 235}U may be detected if the detector is placed in close contact to the specimen. In this research, identification and characterization of uranium bearing materials is experimentally investigated using direct measurement of gamma-rays from {sup 235}U in combination with the x-ray fluorescence (XRF) technique. Measurement of gamma-rays can be conducted by using high purity germanium (HPGe) detector or cadmium telluride (CdTe) detector while a {sup 57}Coradioisotope-excited XRF spectrometer using CdTe detector is used for elemental analysis. The proposed technique was tested with various uranium bearing specimens containing natural, depleted and enriched uranium in both metallic and powder forms.

  18. Photo-responsivity characterizations of CdTe films for direct-conversion X-ray detectors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ryun Kyung; Cha, Bo Kyung; Jeon, Sung Chae; Seo, Chang Woo [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of); Yun, Seung Man [Pusan National University, Busan (Korea, Republic of)

    2014-08-15

    We have fabricated and investigated thin, polycrystalline, cadmium-telluride (CdTe) films in order to utilize them for optical switching readout layers in direct-conversion X-ray detectors. The polycrystalline CdTe films are fabricated on ITO glasses by using the physical vapor deposition (PVD) method at a slow deposition rate and a pressure of 10{sup -6} torr. CdTe films with thicknesses of 5 and 20 μm are grown. The electrical and the optical characteristics of the CdTe films are investigated by measuring the dark-current and the photo-current as functions of the applied field under different wavelengths of light. Higher photo-currents are generated at the longer wavelengths of light for the same applied voltage. When a higher electrical field is applied to the 20 μm-thick CdTe film, a higher dark-current, a higher photo-current, a larger number of charges, and a higher quantum efficiency are generated.

  19. Resonant soft X-ray reflectivity of ultrathin polymer films at the C-edge: A direct approach

    Directory of Open Access Journals (Sweden)

    Alain Gibaud

    2016-09-01

    Full Text Available The use of resonant soft X-ray reflectivity (RSXRR in s-polarization is presented with the aim to show how far it is possible to go in the understanding the evolution of the refractive index n(E=1−δ(E−iβ(E of a ultrathin polystyrene film when the RSXRR is measured through the C-edge. We evidence that a direct fit to the data provides a very good estimation of δ(E and β(E in a large range of energies. Nevertheless, at some specific energy close to C-edge we observe that it is not possible to obtain a satisfactory fit to the data though the same formalism is applied to calculate the reflectivity. We show that even though we take into account the energy resolution of the incident beam, we still end up with a poor fit at these energies. Incorporating the strong contribution of 2nd order photons appeared near C-edge we could not eliminate the discrepancy. Probably the data normalisations have some impacts on such discrepancies at some specific energies.

  20. Resonant soft X-ray reflectivity of ultrathin polymer films at the C-edge: A direct approach

    Science.gov (United States)

    Gibaud, Alain; Bal, Jayanta Kumar; Gullikson, Eric M.; Wang, Cheng; Vignaud, Guillaume

    2016-09-01

    The use of resonant soft X-ray reflectivity (RSXRR) in s-polarization is presented with the aim to show how far it is possible to go in the understanding the evolution of the refractive index n (E ) =1 -δ (E ) -i β (E ) of a ultrathin polystyrene film when the RSXRR is measured through the C-edge. We evidence that a direct fit to the data provides a very good estimation of δ (E ) and β (E ) in a large range of energies. Nevertheless, at some specific energy close to C-edge we observe that it is not possible to obtain a satisfactory fit to the data though the same formalism is applied to calculate the reflectivity. We show that even though we take into account the energy resolution of the incident beam, we still end up with a poor fit at these energies. Incorporating the strong contribution of 2nd order photons appeared near C-edge we could not eliminate the discrepancy. Probably the data normalisations have some impacts on such discrepancies at some specific energies.

  1. Ex-situ time-lapse x-ray CT study of 3D micro-structural fatigue damage evolution in uni-directional composites

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Wang, Ying; Zangenberg Hansen, Jens

    2016-01-01

    In this study, the progress of damage under tension-tension fatigue of a uni-directional (UD) glass fibre composite made from a non-crimp fabric is studied using transilluminated white light imaging (TWLI) and X-ray computed tomography (CT). TWLI images are automatically captured throughout...

  2. Expert knowledge as defined by the X-Ray Ordinance. Directive on competence and expert knowledge in radiation protection, required for operators of X-ray equipment in medicine, dentistry, and veterinary medicine, as defined by the X-Ray Ordinance of January 8, 1987. Fachkunde nach Roentgenverordnung. Richtlinie Fachkunde und Kenntnisse im Strahlenschutz fuer den Betrieb von Roentgeneinrichtungen in der Medizin, Zahnmedizin und Tiermedizin nach der Roentgenverordnung vom 8. Januar 1987

    Energy Technology Data Exchange (ETDEWEB)

    1987-01-01

    The radiation protection officer or any person responsible for radiation safety have to give proof of their expert knowledge in accordance with sections 3, 4 of the X-Ray Ordinance. Proof of expert knowledge has to be furnished within the procedure of appointment (sec. 13, sub-sec. (3) X-Ray Ordinance). The directive defines the scope of the expert knowledge required, and the scope of expert knowledge persons must have, or acquire, who are responsible for radiation protection within the preview of sec. 23, no. 2, 4 and sec. 29, sub-sec. 1, no. 3 of the X-Ray Ordinance.

  3. Design of Highly Directive Ni-Like Ag X-Ray Laser at 13.9 nm

    Institute of Scientific and Technical Information of China (English)

    ZHAO Jing; DONG Quan-Li; WANG Shou-Jun; ZHANG Lei; ZHANG Jie

    2008-01-01

    @@ We theoretically investigate a 13.9 nm Ni-like Ag x-ray laser using a one-dimensional hydrodynamic code coupled with an atomic physics data package. The population inversion is transiently pumped by a grazing incident 0.5 ps main pulse irradiating into an optimized plasma, which is generated by a normal incidence 300 ps pulse and a subsequent grazing incidence 300 ps pulse. The effect of the grazing-incidence angle on the source position of the output x-ray laser is investigated. Near zero deflecting angle is found for the peak output intensity of the Ni-like Ag x-ray lasers, with a small FWHM divergence of 5mrad. It is predicted that saturation can be achieved with a total pump energy of 165mJ.

  4. Compressive sensing for direct millimeter-wave holographic imaging.

    Science.gov (United States)

    Qiao, Lingbo; Wang, Yingxin; Shen, Zongjun; Zhao, Ziran; Chen, Zhiqiang

    2015-04-10

    Direct millimeter-wave (MMW) holographic imaging, which provides both the amplitude and phase information by using the heterodyne mixing technique, is considered a powerful tool for personnel security surveillance. However, MWW imaging systems usually suffer from the problem of high cost or relatively long data acquisition periods for array or single-pixel systems. In this paper, compressive sensing (CS), which aims at sparse sampling, is extended to direct MMW holographic imaging for reducing the number of antenna units or the data acquisition time. First, following the scalar diffraction theory, an exact derivation of the direct MMW holographic reconstruction is presented. Then, CS reconstruction strategies for complex-valued MMW images are introduced based on the derived reconstruction formula. To pursue the applicability for near-field MMW imaging and more complicated imaging targets, three sparsity bases, including total variance, wavelet, and curvelet, are evaluated for the CS reconstruction of MMW images. We also discuss different sampling patterns for single-pixel, linear array and two-dimensional array MMW imaging systems. Both simulations and experiments demonstrate the feasibility of recovering MMW images from measurements at 1/2 or even 1/4 of the Nyquist rate.

  5. Extremity x-ray

    Science.gov (United States)

    ... degenerative) Bone tumor Broken bone (fracture) Dislocated bone Osteomyelitis (infection) Arthritis Other conditions for which the test ... Bone tumor Bone x-ray Broken bone Clubfoot Osteomyelitis X-ray Review Date 7/3/2016 Updated ...

  6. Abdominal x-ray

    Science.gov (United States)

    ... are, or may be, pregnant. Alternative Names Abdominal film; X-ray - abdomen; Flat plate; KUB x-ray ... Assistant Studies, Department of Family Medicine, UW Medicine, School of Medicine, University of Washington, Seattle, WA. Also ...

  7. X-ray diffraction contrast tomography (DCT) system, and an X-ray diffraction contrast tomography (DCT) method

    DEFF Research Database (Denmark)

    2012-01-01

    Source: US2012008736A An X-ray diffraction contrast tomography system (DCT) comprising a laboratory X-ray source (2), a staging device (5) rotating a polycrystalline material sample in the direct path of the X-ray beam, a first X-ray detector (6) detecting the direct X-ray beam being transmitted...... through the crystalline material sample, a second X-ray detector (7) positioned between the staging device and the first X-ray detector for detecting diffracted X-ray beams, and a processing device (15) for analysing detected values. The crystallographic grain orientation of the individual grain...

  8. Fatigue damage assessment of uni-directional non-crimp fabric reinforced polyester composite using X-ray computed tomography

    DEFF Research Database (Denmark)

    Jespersen, Kristine Munk; Zangenberg Hansen, Jens; Lowe, Tristan

    2016-01-01

    In this study, the progression of tension-tension fatigue (R=0.1) damage in a unidirectional (UD) composite made from a non-crimp glass fibre fabric used for wind turbine blades is investigated using multi-scale 3D X-ray computed tomography (CT). Initially, a representative volume is examined...

  9. Direct Synthesis of Carbon Nanotube Field Emitters on Metal Substrate for Open-Type X-ray Source in Medical Imaging.

    Science.gov (United States)

    Gupta, Amar Prasad; Park, Sangjun; Yeo, Seung Jun; Jung, Jaeik; Cho, Chonggil; Paik, Sang Hyun; Park, Hunkuk; Cho, Young Chul; Kim, Seung Hoon; Shin, Ji Hoon; Ahn, Jeung Sun; Ryu, Jehwang

    2017-07-29

    We report the design, fabrication and characterization of a carbon nanotube enabled open-type X-ray system for medical imaging. We directly grew the carbon nanotubes used as electron emitter for electron gun on a non-polished raw metallic rectangular-rounded substrate with an area of 0.1377 cm² through a plasma enhanced chemical vapor deposition system. The stable field emission properties with triode electrodes after electrical aging treatment showed an anode emission current of 0.63 mA at a gate field of 7.51 V/μm. The 4.5-inch cubic shape open type X-ray system was developed consisting of an X-ray aperture, a vacuum part, an anode high voltage part, and a field emission electron gun including three electrodes with focusing, gate and cathode electrodes. Using this system, we obtained high-resolution X-ray images accelerated at 42-70 kV voltage by digital switching control between emitter and ground electrode.

  10. Direct Synthesis of Carbon Nanotube Field Emitters on Metal Substrate for Open-Type X-ray Source in Medical Imaging

    Directory of Open Access Journals (Sweden)

    Amar Prasad Gupta

    2017-07-01

    Full Text Available We report the design, fabrication and characterization of a carbon nanotube enabled open-type X-ray system for medical imaging. We directly grew the carbon nanotubes used as electron emitter for electron gun on a non-polished raw metallic rectangular-rounded substrate with an area of 0.1377 cm2 through a plasma enhanced chemical vapor deposition system. The stable field emission properties with triode electrodes after electrical aging treatment showed an anode emission current of 0.63 mA at a gate field of 7.51 V/μm. The 4.5-inch cubic shape open type X-ray system was developed consisting of an X-ray aperture, a vacuum part, an anode high voltage part, and a field emission electron gun including three electrodes with focusing, gate and cathode electrodes. Using this system, we obtained high-resolution X-ray images accelerated at 42–70 kV voltage by digital switching control between emitter and ground electrode.

  11. X-Ray Supernovae

    CERN Document Server

    Immler, S; Immler, Stefan; Lewin, Walter H.G.

    2002-01-01

    We present a review of X-ray observations of supernovae (SNe). By observing the (~0.1--100 keV) X-ray emission from young SNe, physical key parameters such as the circumstellar matter (CSM) density, mass-loss rate of the progenitor and temperature of the outgoing and reverse shock can be derived as a function of time. Despite intensive search over the last ~25 years, only 15 SNe have been detected in X-rays. We review the individual X-ray observations of these SNe and discuss their implications as to our understanding of the physical processes giving rise to the X-ray emission.

  12. Evaluation of X-ray fluorescence spectroscopy as a method for the rapid and direct determination of sodium in cheese.

    Science.gov (United States)

    Stankey, J A; Akbulut, C; Romero, J E; Govindasamy-Lucey, S

    2015-08-01

    Cheese manufacturers indirectly determine Na in cheese by analysis of Cl using the Volhard method, assuming that all Cl came from NaCl. This method overestimates the actual Na content in cheeses when Na replacers (e.g., KCl) are used. A direct and rapid method for Na detection is needed. X-ray fluorescence spectroscopy (XRF), a mineral analysis technique used in the mining industry, was investigated as an alternative method of Na detection in cheese. An XRF method for the detection of Na in cheese was developed and compared with inductively coupled plasma optical emission spectroscopy (ICP-OES; the reference method for Na in cheese) and Cl analyzer. Sodium quantification was performed by multi-point calibration with cheese standards spiked with NaCl ranging from 0 to 4% Na (wt/wt). The Na concentration of each of the cheese standards (discs: 30mm×7mm) was quantified by the 3 methods. A single laboratory method validation was performed; linearity, precision, limit of detection, and limit of quantification were determined. An additional calibration graph was created using cheese standards made from natural or process cheeses manufactured with different ratios of Na:K. Both Na and K calibration curves were linear for the cheese standards. Sodium was quantified in a variety of commercial cheese samples. The Na data obtained by XRF were in agreement with those from ICP-OES and Cl analyzer for most commercial natural cheeses. The XRF method did not accurately determine Na concentration for several process cheese samples, compared with ICP-OES, likely due to the use of unknown types of Na-based emulsifying salts (ES). When a calibration curve was created for process cheese with the specific types of ES used for this cheese, Na content was successfully predicted in the samples. For natural cheeses, the limit of detection and limit of quantification for Na that can be determined with an acceptable level of repeatability, precision, and trueness was 82 and 246mg/100g of

  13. Flow visualization and void fraction measurement in liquid-metal/water direct contact heat exchange by X-ray attenuation technique

    Science.gov (United States)

    Liu, Xin

    One concept being considered for steam generation in particular next generation nuclear reactor designs, involves water coming into direct contact with a circulating molten metal. To optimize the design of such direct contact heat exchange and vaporization systems, detailed knowledge is necessary of the various flow regimes, interfacial transport phenomena, heat transfer and operational stability. With the development of high performance digital detectors, radiography using X-rays or neutrons maybe a suitable technique to obtain information about that direct-contact interaction; i.e., void volume fractions, length scales and dynamic behavior. Under the basis of previous investigations, a complete methodology of the X-ray radiography for two-phase flow measurement has been developed from the facility and imaging analysis aspects. Through this developed methodology, a high energy X-ray imaging system is optimized for the direct-contact heat exchange experiment. Beside an on-line calibration procedure which practically quantifies the imaging system's performance, the extended linear system theory and Rose's model have also been used to evaluate the imaging system's performance, respectively. The bottleneck of the current imaging system and the future of system improvement direction have been pointed out. With our real-time, large-area high energy X-ray imaging system, the two-phase flow was visualized and stored digitally. An efficient image processing strategy has also been established by combining several optimal digital image processing algorithms. The approach has been implemented into a software computational tool written in MATLAB called T-XIP. Time-dependent heat transfer related variables, such as void fraction (void volume), local heat transfer coefficient, etc., were calculated using this software tool. Finally, an error analysis associated with the void fraction measurement has been given based on two procedures.

  14. In-situ visualization of N2 evolution in operating direct hydrazine hydrate fuel cell by soft X-ray radiography

    Science.gov (United States)

    Sakamoto, Tomokazu; Deevanhxay, Phengxay; Asazawa, Koichiro; Tsushima, Shohji; Hirai, Shuichiro; Tanaka, Hirohisa

    2014-04-01

    Soft X-ray radiography technique was firstly applied to operating direct hydrazine hydrate fuel cell (DHFCs) in order to visualize N2 gas behaviors with high spatial and temporal resolution. Two different cells for in-situ visualization of N2 gas in the DHFCs in in-plane and through-plane direction were designed and fabricated. The utilization of soft X-ray made the visualization of generated N2 behavior in the DHFC possible with the spatial resolution of 1.5 μm and the temporal resolution of 2.0 s frame-1. In the in-plane visualization, the inhomogeneous N2 gas distribution, suggesting non-uniform reaction distribution in the anode of DHFC, was observed. In the through-plane visualization, N2 gas accumulation under the rib of anode and discharge to the channel was clearly observed, which are related with cell performance instability.

  15. Direct determination of trace elements in boron nitride powders by slurry sampling total reflection X-ray fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Amberger, Martin A.; Hoeltig, Michael [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany); Broekaert, Jose A.C., E-mail: jose.broekaert@chemie.uni-hamburg.d [University of Hamburg, Institute for Inorganic and Applied Chemistry, Martin-Luther-King-Platz 6, D-20146 Hamburg (Germany)

    2010-02-15

    The use of slurry sampling total reflection X-ray fluorescence spectrometry (SlS-TXRF) for the direct determination of Ca, Cr, Cu, Fe, Mn and Ti in four boron nitride powders has been described. Measurements of the zeta potential showed that slurries with good stabilities can be obtained by the addition of polyethylenimine (PEI) at a concentration of 0.1 wt.% and by adjusting the pH at 4. For the optimization of the concentration of boron nitride in the slurries the net line intensities and the signal to background ratios were determined for the trace elements Ca and Ti as well as for the internal standard element Ga in the case of concentrations of boron nitride ranging from 1 to 30 mg mL{sup -1}. As a compromise with respect to high net line intensities and high signal to background ratios, concentrations of 5 mg mL{sup -1} of boron nitride were found suitable and were used for all further measurements. The limits of detection of SlS-TXRF for the boron nitride powders were found to range from 0.062 to 1.6 mug g{sup -1} for Cu and Ca, respectively. Herewith, they are higher than those obtained in solid sampling and slurry sampling graphite furnace atomic absorption spectrometry (SoS-GFAAS, SlS-GFAAS) as well as those of solid sampling electrothermal evaporation inductively coupled plasma optical emission spectrometry (SoS-ETV-ICP-OES). For Ca and Fe as well as for Cu and Fe, however, they were found to be lower than for GFAAS and for ICP-OES subsequent to wet chemical digestion, respectively. The universal applicability of SlS-TXRF to the analysis of samples with a wide variety of matrices could be demonstrated by the analysis of certified reference materials such as SiC, Al{sub 2}O{sub 3}, powdered bovine liver and borate ore with a single calibration. The correlation coefficients of the plots for the values found for Ca, Fe and Ti by SlS-TXRF in the boron nitride powders as well as in the before mentioned samples versus the reference values for the respective

  16. Direct determination of intermolecular structure of ethanol adsorbed in micropores using X-ray diffraction and reverse Monte Carlo analysis

    OpenAIRE

    Iiyama, Taku; Hagi, Kousuke; Urushibara, Takafumi; Ozeki, Sumio

    2009-01-01

    The intermolecular structure of C(2)H(5)OH molecules confined in slit-shaped graphitic micropore of activated carbon fiber was investigated by in situ X-ray diffraction (XRD) measurement and reverse Monte Carlo (RMC) analysis. The pseudo-3-dimensional intermolecular structure Of C(2)H(5)OH adsorbed in the micropores was determined by applying the RMC analysis to XRD data, assuming a simple slit-shaped space composed of double graphene sheets. The results were consistent with conventional Mont...

  17. New Directions in X-Ray Light Sources or Fiat Lux: what's under the dome and watching atoms with x-rays (LBNL Summer Lecture Series)

    Energy Technology Data Exchange (ETDEWEB)

    Falcone, Roger

    2008-07-15

    Summer Lecture Series 2008: Molecular movies of chemical reactions and material phase transformations need a strobe of x-rays, the penetrating light that reveals how atoms and molecules assemble in chemical and biological systems and complex materials. Roger Falcone, Director of the Advanced Light Source,will discuss a new generation of x ray sources that will enable a new science of atomic dynamics on ultrafast timescales.

  18. Color multiplexing using directional holographic gratings and linear polarization

    Energy Technology Data Exchange (ETDEWEB)

    Lugo, L I; Rodriguez, A; Ramirez, G; Guel, S; Nunez, O F, E-mail: roca@cactus.iico.uaslp.mx [Instituto de Investigacion en Comunicacion Optica (IICO) Universidad Autonoma de San Luis Potosi, S.L.P. (UASLP) (Mexico)

    2011-01-01

    We propose a system of multiplexing and de-multiplexing, which uses a holographic diffraction grating to compel modulated light of different colors to be sent through an optical fiber. Diffraction gratings were fabricated specifically to pick the desired direction in which we wanted the light of different wavelengths to impinge the optic fiber, and also to be separated at the output. It was been found that the system preserves the polarization of light, which give us a one more freedom degree, allowing us to process twice the original information amount.

  19. X-Ray Polarimetry

    CERN Document Server

    Kaaret, Philip

    2014-01-01

    We review the basic principles of X-ray polarimetry and current detector technologies based on the photoelectric effect, Bragg reflection, and Compton scattering. Recent technological advances in high-spatial-resolution gas-filled X-ray detectors have enabled efficient polarimeters exploiting the photoelectric effect that hold great scientific promise for X-ray polarimetry in the 2-10 keV band. Advances in the fabrication of multilayer optics have made feasible the construction of broad-band soft X-ray polarimeters based on Bragg reflection. Developments in scintillator and solid-state hard X-ray detectors facilitate construction of both modular, large area Compton scattering polarimeters and compact devices suitable for use with focusing X-ray telescopes.

  20. Direct observation of high-spin states in manganese dimer and trimer cations by x-ray magnetic circular dichroism spectroscopy in an ion trap

    Energy Technology Data Exchange (ETDEWEB)

    Zamudio-Bayer, V. [Physikalisches Institut, Universität Freiburg, Stefan-Meier-Straße 21, 79104 Freiburg (Germany); Institut für Methoden und Instrumentierung der Forschung mit Synchrotronstrahlung, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Straße 15, 12489 Berlin (Germany); Hirsch, K.; Langenberg, A.; Kossick, M. [Institut für Methoden und Instrumentierung der Forschung mit Synchrotronstrahlung, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Straße 15, 12489 Berlin (Germany); Institut für Optik und Atomare Physik, Technische Universität Berlin, Hardenbergstraße 36, 10623 Berlin (Germany); Ławicki, A.; Lau, J. T., E-mail: tobias.lau@helmholtz-berlin.de [Institut für Methoden und Instrumentierung der Forschung mit Synchrotronstrahlung, Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Albert-Einstein-Straße 15, 12489 Berlin (Germany); Terasaki, A. [Cluster Research Laboratory, Toyota Technological Institute, 717-86 Futamata, Ichikawa, Chiba 272-0001 (Japan); Department of Chemistry, Kyushu University, 6-10-1 Hakozaki, Higashi-ku, Fukuoka 812-8581 (Japan); Issendorff, B. von [Physikalisches Institut, Universität Freiburg, Stefan-Meier-Straße 21, 79104 Freiburg (Germany)

    2015-06-21

    The electronic structure and magnetic moments of free Mn{sub 2}{sup +} and Mn{sub 3}{sup +} are characterized by 2p x-ray absorption and x-ray magnetic circular dichroism spectroscopy in a cryogenic ion trap that is coupled to a synchrotron radiation beamline. Our results directly show that localized magnetic moments of 5 μ{sub B} are created by 3d{sup 5}({sup 6}S) states at each ionic core, which are coupled ferromagnetically to form molecular high-spin states via indirect exchange that is mediated in both cases by a delocalized valence electron in a singly occupied 4s derived antibonding molecular orbital with an unpaired spin. This leads to total magnetic moments of 11 μ{sub B} for Mn{sub 2}{sup +} and 16 μ{sub B} for Mn{sub 3}{sup +}, with no contribution of orbital angular momentum.

  1. Direct analysis of blood serum by total reflection X-ray fluorescence spectrometry and application of an artificial neural network approach for cancer diagnosis*1

    Science.gov (United States)

    Hernández-Caraballo, Edwin A.; Marcó-Parra, Lué M.

    2003-12-01

    Iron, copper, zinc and selenium were determined directly in serum samples from healthy individuals ( n=33) and cancer patients ( n=27) by total reflection X-ray fluorescence spectrometry using the Compton peak as internal standard [L.M. Marcó P. et al., Spectrochim. Acta Part B 54 (1999) 1469-1480]. The standardized concentrations of these elements were used as input data for two-layer artificial neural networks trained with the generalized delta rule in order to classify such individuals according to their health status. Various artificial neural networks, comprising a linear function in the input layer, a hyperbolic tangent function in the hidden layer and a sigmoid function in the output layer, were evaluated for such a purpose. Of the networks studied, the (4:4:1) gave the highest estimation (98%) and prediction rates (94%). The latter demonstrates the potential of the total reflection X-ray fluorescence spectrometry/artificial neural network approach in clinical chemistry.

  2. Direct Observation of High-Spin States in Manganese Dimer and Trimer Cations by X-ray Magnetic Circular Dichroism Spectroscopy in an Ion Trap

    CERN Document Server

    Zamudio-Bayer, Vicente; Langenberg, Andreas; Kossick, Martin; Ławicki, Arkadiusz; Terasaki, Akira; von Issendorff, Bernd; Lau, J Tobias

    2015-01-01

    The electronic structure and magnetic moments of free Mn$_2^+$ and Mn$_3^+$ are characterized by $2p$ x-ray absorption and x-ray magnetic circular dichroism spectroscopy in a cryogenic ion trap that is coupled to a synchrotron radiation beamline. Our results show directly that localized magnetic moments of 5 $\\mu_B$ are created by $3d^5 (^6\\mathrm{S})$ states at each ionic core, which are coupled in parallel to form molecular high-spin states via indirect exchange that is mediated in both cases by a delocalized valence electron in a singly-occupied $4s$ derived orbital with an unpaired spin. This leads to total magnetic moments of 11 $\\mu_B$ for Mn$_2^+$ and 16 $\\mu_B$ for Mn$_3^+$, with no contribution of orbital angular momentum.

  3. Direct correlation of solar cell performance with metal impurity distributions in polycrystalline silicon using synchrotron-based x-ray analysis

    Energy Technology Data Exchange (ETDEWEB)

    McHugo, S.A.; Thompson, A.C.; Lamble, G. [Lawrence Berkeley National Lab., CA (United States)] [and others

    1998-12-31

    The work presented here directly measures metal impurity distributions and their chemical state in as-grown and fully processed polycrystalline silicon sued for terrestrial-based solar cells. The goal was to determine if a correlation exists between poorly performing regions of solar cells and metal impurity distributions as well as to ascertain the chemical state of the impurities. Synchrotron-based x-ray fluorescence mapping and x-ray absorption spectroscopy, both with a spatial resolution of 1 {micro}m, were used to measure impurity distributions and chemical state, respectively, in poorly performing regions of polycrystalline silicon. The Light Beam Induced Current method was used to measure minority carrier recombination in the material in order to identify poor performance regions. The authors have detected iron, chromium, nickel, gold and copper impurity precipitates and they have recognized a direct correlation between impurity distributions and poor performing regions in both as-grown and fully processed material. Furthermore, from x-ray absorption studies, they have initial results, indicating that the Fe in this material is in oxide form, not FeSi{sub 2}. These results provide a fundamental understanding into the efficiency-limiting factors of polycrystalline silicon solar cells as well as yielding insight for methods of solar cell improvement.

  4. [Correlation between basic imaging properties and subjective evaluations of two digital radiographic X-ray systems based on direct-conversion flat panel detector].

    Science.gov (United States)

    Sakaguchi, Taro; Katayama, Reiji; Morishita, Junji; Sakai, Shinji; Kuroki, Hidefumi; Ohkubo, Seiji; Maeda, Takashi; Hayabuchi, Naofumi

    2010-11-20

    The purpose of this study was to examine the correlation between the basic imaging properties of two digital radiographic X-ray systems with a direct conversion flat-panel detector and their image qualities, which were evaluated by the observer in hard copy and soft copy studies. The subjective image quality was evaluated and compared in terms of the low-contrast detectability and image sharpness in the two digital radiographic X-ray systems. We applied the radiographs of a contrast detail phantom to the evaluation of low-contrast detectability and analyzed the contrast detail diagrams. Finally, low-contrast detectability was evaluated by the image quality figure (IQF) calculated from the contrast detail diagrams. Also, the subjective image sharpness of human dry bones of two systems was examined and evaluated by the normalized-rank method. The results indicated that System A tended to provide superior subjective image quality compared to System B in both observer studies. We also found high correlations between IQFs and basic imaging properties, such as the noise power spectrum (NPS) and the noise equivalent quantum (NEQ). In conclusion, the low-contrast detectability of the two digital radiographic X-ray systems with a direct conversion flat-panel detector corresponded to the NPS and the NEQ in both outputs (soft copy and hard copy). On the other hand, the subjective image sharpness of human dry bones was affected by their noise properties.

  5. Determining the orientation angle of directional leads for deep brain stimulation using computed tomography and digital x-ray imaging: A phantom study.

    Science.gov (United States)

    Sitz, Alexander; Hoevels, Mauritius; Hellerbach, Alexandra; Gierich, Andreas; Luyken, Klaus; Dembek, Till A; Klehr, Martin; Wirths, Jochen; Visser-Vandewalle, Veerle; Treuer, Harald

    2017-09-01

    Orientating the angle of directional leads for deep brain stimulation (DBS) in an axial plane introduces a new degree of freedom that is indicated by embedded anisotropic directional markers. Our aim was to develop algorithms to determine lead orientation angles from computed tomography (CT) and stereotactic x-ray imaging using standard clinical protocols, and subsequently assess the accuracy of both methods. In CT the anisotropic marker artifact was taken as a signature of the lead orientation angle and analyzed using discrete Fourier transform of circular intensity profiles. The orientation angle was determined from phase angles at a frequency 2/360° and corrected for aberrations at oblique leads. In x-ray imaging, frontal and lateral images were registered to stereotactic space and sub-images containing directional markers were extracted. These images were compared with projection images of an identically located virtual marker at different orientation angles. A similarity index was calculated and used to determine the lead orientation angle. Both methods were tested using epoxy phantoms containing directional leads (Cartesia™, Boston Scientific, Marlborough, USA) with known orientation. Anthropomorphic phantoms were used to compare both methods for DBS cases. Mean deviation between CT and x-ray was 1.5° ± 3.6° (range: -2.3° to 7.9°) for epoxy phantoms and 3.6° ± 7.1° (range: -5.6° to 14.6°) for anthropomorphic phantoms. After correction for imperfections in the epoxy phantoms, the mean deviation from ground truth was 0.0° ± 5.0° (range: -12° to 14°) for x-ray. For CT the results depended on the polar angle of the lead in the scanner. Mean deviation was -0.3° ± 1.9° (range: -4.6° to 6.6°) or 1.6° ± 8.9° (range: -23° to 34°) for polar angles ≤ 40° or > 40°. The results show that both imaging modalities can be used to determine lead orientation angles with high accuracy. CT is superior to x-ray imaging, but oblique leads (polar

  6. Topological X-Rays and MRIs

    Science.gov (United States)

    Lynch, Mark

    2002-01-01

    Let K be a compact subset of the interior of the unit disk D in the plane and suppose one can't see through the boundary of D and identify K. However, assume that one can take "topological X-rays" of D which measure the "density" of K along the lines of the X-rays. By taking these X-rays from all directions, a "topological MRI" is generated for…

  7. Measurements of the ablation-front trajectory and low-mode nonuniformity in direct-drive implosions using x-ray self-emission shadowgraphy

    Institute of Scientific and Technical Information of China (English)

    D.T.Michel; A.K.Davis; W.Armstrong; R.Bahr; R.Epstein; V.N.Goncharov; M.Hohenberger; I.V.Igumenshchev; R.Jungquist; D.D.Meyerhofer; P.B.Radha; T.C.Sangster; C.Sorce; D.H.Froula

    2015-01-01

    Self-emission x-ray shadowgraphy provides a method to measure the ablation-front trajectory and low-mode nonuniformity of a target imploded by directly illuminating a fusion capsule with laser beams. The technique uses time-resolved images of soft x-rays(>1 ke V) emitted from the coronal plasma of the target imaged onto an x-ray framing camera to determine the position of the ablation front. Methods used to accurately measure the ablation-front radius(δ R= ±1.15 μm), image-to-image timing(δ( t)= ±2.5 ps) and absolute timing(δt= ±10 ps) are presented.Angular averaging of the images provides an average radius measurement of δ( Rav)= ±0.15 μm and an error in velocity of δV / V= ±3%. This technique was applied on the Omega Laser Facility [Boehly et al., Opt. Commun. 133, 495(1997)] and the National Ignition Facility [Campbell and Hogan, Plasma Phys. Control. Fusion 41, B39(1999)].

  8. Effect of x-ray incident direction and scintillator layer design on image quality of indirect-conversion flat-panel detector with GOS phosphor

    Science.gov (United States)

    Sato, K.; Nariyuki, F.; Nomura, H.; Takasu, A.; Fukui, S.; Nakatsu, M.; Okada, Y.; Nabeta, T.; Hosoi, Y.

    2011-03-01

    In this study, we characterized the image quality of two types of indirect-conversion flat-panel detectors: an X-ray incident-side photo-detection system (IS) and an X-ray penetration-side photo-detection system (PS). These detectors consist of a Gd2O2S:Tb (GOS) scintillator coupled with a photodiode thin film transistor (PD-TFT) array on a glass substrate. The detectors have different X-ray incident directions, glass substrates, and scintillators. We also characterized the effects of layered scintillator structures on the image quality by using a single-layered scintillator containing large phosphor grains and a double-layered scintillator consisting of a layer of large phosphor grains and a layer of small phosphor grains. The IS system consistently demonstrated a higher MTF than the PS system for a scintillator of the same thickness. Moreover, the IS system showed a higher DQE than the PS system when a thick scintillator was used. While the double-layered scintillators were useful for improving the MTF in both systems, a thick single-layered scintillator was preferable for obtaining a high DQE when the IS system was applied. These results indicate that an IS system can efficiently utilize the light emitted from the phosphor at the far side of the PD without the occurrence of blurring. The use of IS systems makes it possible to increase the thickness of the scintillator layer for improving the sensitivity without reducing the MTF, which increases the DQE. The DQE of the IS system was 1.2 times that of the PS system, despite the absorption of X-rays at the glass substrate before entering the phosphor.

  9. Direct measurement of the position accuracy for low energy X-ray photons with a pnCCD

    Science.gov (United States)

    Ihle, S.; Holl, P.; Kalok, D.; Hartmann, R.; Ryll, H.; Steigenhöfer, D.; Strüder, L.

    2017-02-01

    We undertook a comparative study on optimizing the position accuracy of pnCCDs for single X-ray photon measurements. Various methods were analyzed by Monte Carlo simulations and related to experimental data obtained with a focused X-ray beam. Even with low energy photons of 1320 eV, a position accuracy much smaller than the actual pixel size of 48 μm × 48 μm can be achieved. This is possible since signal charges from a single photon interaction spread into more than one pixel, allowing a reconstruction of the original point of interaction. We found that a) making a decision on which pixels to use for the reconstruction and b) choosing a centroiding algorithm for carrying out the reconstruction were particularly crucial. For a) we introduce a new and superior method using a two step analysis with an adaptive pattern. It is compared to using a threshold or a fixed pattern. For b) we present a Center-of-Gravity method with a Gaussian correction taking into account the shape of the signal charge cloud. Both methods are also optimized for fast execution by implementing lookup tables rather than time consuming calculations. Our results show that with the appropriate analysis an uncertainty of the position measurement of better than 3.0 μm rms for 1320 eV photons is possible.

  10. X-Ray

    Science.gov (United States)

    ... You may be allowed to remain with your child during the test. If you remain in the room during the X-ray exposure, you'll likely be asked to wear a lead apron to shield you from unnecessary exposure. After the X-ray ...

  11. Dental x-rays

    Science.gov (United States)

    ... X-rays are a form of high energy electromagnetic radiation. The x-rays penetrate the body to form ... for detecting cavities, unless the decay is very advanced and deep. Many ... The amount of radiation given off during the procedure is less than ...

  12. X-ray Polarimetry

    Science.gov (United States)

    Kallman, T.

    In spite of the recent advances in X-ray instrumentation, polarimetry remains an area which has been virtually unexplored in the last 20 years. The scientific motivation to study polarization has increased during this time: emission models designed to repro- duce X-ray spectra can be tested using polarization, and polarization detected in other wavelength bands makes clear predictions as to the X-ray polarization. Polarization remains the only way to infer geometrical properties of sources which are too small to be spatially resolved. At the same time, there has been recent progress in instrumen- tation which is likely to allow searches for X-ray polarization at levels significantly below what was possible for early detectors. In this talk I will review the history of X-ray polarimetry, discuss some experimental techniques and the scientific problems which can be addressed by future experiments.

  13. Direct observation of bi-alkali antimonide photocathodes growth via in operando x-ray diffraction studies

    Directory of Open Access Journals (Sweden)

    M. Ruiz-Osés

    2014-12-01

    Full Text Available Alkali antimonides have a long history as visible-light-sensitive photocathodes. This work focuses on the process of fabrication of the bi-alkali photocathodes, K2CsSb. In-situ synchrotron x-ray diffraction and photoresponse measurements were used to monitor phase evolution during sequential photocathode growth mode on Si(100 substrates. The amorphous-to-crystalline transition for the initial antimony layer was observed at a film thickness of 40 Å . The antimony crystalline structure dissolved upon potassium deposition, eventually recrystallizing upon further deposition into K-Sb crystalline modifications. This transition, as well as the conversion of potassium antimonide to K2CsSb upon cesium deposition, is correlated with changes in the quantum efficiency.

  14. Direct experimental determination of spiral spin structures via the dichroism extinction effect in resonant elastic soft x-ray scattering

    Science.gov (United States)

    Zhang, S. L.; van der Laan, G.; Hesjedal, T.

    2017-09-01

    Long-wavelength spin spiral structures are ubiquitous in a large variety of magnetic materials. The detailed magnetic structure can take many variations owing to their different physical origins. Therefore, the unambiguous structural determination is crucial for understanding these spin systems, though such a task is experimentally challenging. Here, we show that ordered spin spiral structures can be fully determined in a single measurement by dichroic resonant elastic x-ray scattering using circularly polarized light. It is found that at certain geometrical conditions, the circular dichroism of the diffraction vanishes completely, revealing a one-to-one correspondence with the spin structure. We demonstrate both theoretically and experimentally this experimental principle, which allows for unambiguous structure determination immediately from the measured signal, whereby no modeling-based data refinement is needed. This largely expands the capabilities of conventional magnetic characterization techniques.

  15. Direct measurement procedure for three-dimensional local crack driving force using synchrotron X-ray microtomography

    Energy Technology Data Exchange (ETDEWEB)

    Toda, H. [Department of Production Systems Engineering, Toyohashi University of Technology, 1-1, Hibarigaoka, Tempaku, Toyohashi, Aichi 441-8580 (Japan)], E-mail: toda@pse.tut.ac.jp; Yamamoto, S.; Kobayashi, M. [Department of Production Systems Engineering, Toyohashi University of Technology, 1-1, Hibarigaoka, Tempaku, Toyohashi, Aichi 441-8580 (Japan); Uesugi, K. [Japan Synchrotron Radiation Research Institute, 1-1-1, Kouto, Mikazuki-cho, Sayo-gun, Hyogo 679-5198 (Japan); Zhang, H. [Department of Production Systems Engineering, Toyohashi University of Technology, 1-1, Hibarigaoka, Tempaku, Toyohashi, Aichi 441-8580 (Japan)

    2008-12-15

    X-ray microtomography has been utilized for the observation of ductile fractures in an aluminum alloy with an Al/Al-Si dual phase structure. A procedure for analyzing a series of tomographic images is proposed for extracting the variation in the local crack-tip opening displacement (CTOD), and its feasibility is confirmed. Complicated crack growth behavior and the formation of uncracked ligaments ahead of a crack tip are observed in the alloy owing to the marked difference in local fracture toughness between the two phases. The proposed technique has provided a quantitative interpretation for such phenomena. It is clarified that a conventional measurement significantly overestimates the CTOD level. The transition behavior in CTOD has been revealed over a certain distance across an interface between the two phases, suggesting the existence of scaling effects that influence the microstructure/fracture relationship. Overall the current method could offer a highly effective way of assessing three-dimensional local fracture behavior.

  16. X-ray crystallography

    Science.gov (United States)

    2001-01-01

    X-rays diffracted from a well-ordered protein crystal create sharp patterns of scattered light on film. A computer can use these patterns to generate a model of a protein molecule. To analyze the selected crystal, an X-ray crystallographer shines X-rays through the crystal. Unlike a single dental X-ray, which produces a shadow image of a tooth, these X-rays have to be taken many times from different angles to produce a pattern from the scattered light, a map of the intensity of the X-rays after they diffract through the crystal. The X-rays bounce off the electron clouds that form the outer structure of each atom. A flawed crystal will yield a blurry pattern; a well-ordered protein crystal yields a series of sharp diffraction patterns. From these patterns, researchers build an electron density map. With powerful computers and a lot of calculations, scientists can use the electron density patterns to determine the structure of the protein and make a computer-generated model of the structure. The models let researchers improve their understanding of how the protein functions. They also allow scientists to look for receptor sites and active areas that control a protein's function and role in the progress of diseases. From there, pharmaceutical researchers can design molecules that fit the active site, much like a key and lock, so that the protein is locked without affecting the rest of the body. This is called structure-based drug design.

  17. X-ray lasers

    CERN Document Server

    Elton, Raymond C

    2012-01-01

    The first in its field, this book is both an introduction to x-ray lasers and a how-to guide for specialists. It provides new entrants and others interested in the field with a comprehensive overview and describes useful examples of analysis and experiments as background and guidance for researchers undertaking new laser designs. In one succinct volume, X-Ray Lasers collects the knowledge and experience gained in two decades of x-ray laser development and conveys the exciting challenges and possibilities still to come._Add on for longer version of blurb_M>The reader is first introduced

  18. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90° Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated ~ 300 fs, 30 keV (0.4 Å) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has been demonstrated as a

  19. Ultrashort X-ray pulse science

    Energy Technology Data Exchange (ETDEWEB)

    Chin, Alan Hap [Univ. of California, Berkeley, CA (US). Dept. of Physics; Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    1998-05-01

    A variety of phenomena involves atomic motion on the femtosecond time-scale. These phenomena have been studied using ultrashort optical pulses, which indirectly probe atomic positions through changes in optical properties. Because x-rays can more directly probe atomic positions, ultrashort x-ray pulses are better suited for the study of ultrafast structural dynamics. One approach towards generating ultrashort x-ray pulses is by 90{sup o} Thomson scattering between terawatt laser pulses and relativistic electrons. Using this technique, the author generated {approx} 300 fs, 30 keV (0.4 {angstrom}) x-ray pulses. These x-ray pulses are absolutely synchronized with ultrashort laser pulses, allowing femtosecond optical pump/x-ray probe experiments to be performed. Using the right-angle Thomson scattering x-ray source, the author performed time-resolved x-ray diffraction studies of laser-perturbated InSb. These experiments revealed a delayed onset of lattice expansion. This delay is due to the energy relaxation from a dense electron-hole plasma to the lattice. The dense electron-hole plasma first undergoes Auger recombination, which reduces the carrier concentration while maintaining energy content. Longitudinal-optic (LO) phonon emission then couples energy to the lattice. LO phonon decay into acoustic phonons, and acoustic phonon propagation then causes the growth of a thermally expanded layer. Source characterization is instrumental in utilizing ultrashort x-ray pulses in time-resolved x-ray spectroscopies. By measurement of the electron beam diameter at the generation point, the pulse duration of the Thomson scattered x-rays is determined. Analysis of the Thomson scattered x-ray beam properties also provides a novel means of electron bunch characterization. Although the pulse duration is inferred for the Thomson scattering x-ray source, direct measurement is required for other x-ray pulse sources. A method based on the laser-assisted photoelectric effect (LAPE) has

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  1. Feasibility for direct rapid energy dispersive X-ray fluorescence (EDXRF) and scattering analysis of complex matrix liquids by partial least squares.

    Science.gov (United States)

    Angeyo, K H; Gari, S; Mustapha, A O; Mangala, J M

    2012-11-01

    The greatest challenge to material characterization by XRF technique is encountered in direct trace analysis of complex matrices. We exploited partial least squares (PLS) in conjunction with energy dispersive X-ray fluorescence and scattering (EDXRFS) spectrometry to rapidly (200 s) analyze lubricating oils. The PLS-EDXRFS method affords non-invasive quality assurance (QA) analysis of complex matrix liquids as it gave optimistic results for both heavy- and low-Z metal additives. Scatter peaks may further be used for QA characterization via the light elements.

  2. Direct Synthesis of Carbon Nanotube Field Emitters on Metal Substrate for Open-Type X-ray Source in Medical Imaging

    OpenAIRE

    Amar Prasad Gupta; Sangjun Park; Seung Jun Yeo; Jaeik Jung; Chonggil Cho; Sang Hyun Paik; Hunkuk Park; Young Chul Cho; Seung Hoon Kim; Ji Hoon Shin; Jeung Sun Ahn; Jehwang Ryu

    2017-01-01

    We report the design, fabrication and characterization of a carbon nanotube enabled open-type X-ray system for medical imaging. We directly grew the carbon nanotubes used as electron emitter for electron gun on a non-polished raw metallic rectangular-rounded substrate with an area of 0.1377 cm2 through a plasma enhanced chemical vapor deposition system. The stable field emission properties with triode electrodes after electrical aging treatment showed an anode emission current of 0.63 mA at a...

  3. Comparison of direct (X-ray diffraction and infrared spectrophotometry) and indirect (infrared spectrophotometry) methods for the analysis of alpha-quartz in airborne dusts.

    Science.gov (United States)

    Kauffer, E; Masson, A; Moulut, J C; Lecaque, T; Protois, J C

    2005-11-01

    In this study, the alpha-quartz contents measured by different analytical techniques (X-ray diffraction, direct method; and infrared spectrophotometry, direct and indirect methods) were compared. The analyses were carried out on filters sampled in an industrial setting by means of a Dorr-Oliver cyclone. To verify the methodology used, filters loaded with pure alpha-quartz were also analysed. By and large, the agreement between the two direct methods was close on average, but on the basis of a comparison of the individual results, considerable differences exist. In absolute value, the mean relative deviation between the two techniques was infrared) were on average 13% lower than the results obtained by the two direct methods with a more important difference (23%) for samples where calcite was identified by X-ray diffraction in comparison with those where it was not (8%). This underestimation, which was not owing to dust losses during preparation, is probably explained by the elimination of organic compounds during dust calcinations or by the transformation of mineral compounds. The indirect method introduces additional sample handling operations with more risk of material loss. When the quantity of calcined material was <0.4 mg, the weighing operations necessary to correct any losses of material resulted in considerable variability. In terms of overall uncertainty, it would be better in this case not to carry out correction and to employ an operating mode favouring the recovery of a maximum of material while accepting a bias of about 5-7%.

  4. Bone x-ray

    Science.gov (United States)

    ... or broken bone Bone tumors Degenerative bone conditions Osteomyelitis (inflammation of the bone caused by an infection) ... Multiple myeloma Osgood-Schlatter disease Osteogenesis imperfecta Osteomalacia Osteomyelitis Paget disease of the bone Rickets X-ray ...

  5. Hand x-ray

    Science.gov (United States)

    ... include fractures, bone tumors , degenerative bone conditions, and osteomyelitis (inflammation of the bone caused by an infection). ... chap 46. Read More Bone tumor Broken bone Osteomyelitis X-ray Review Date 9/8/2014 Updated ...

  6. Pelvis x-ray

    Science.gov (United States)

    X-ray - pelvis ... Tumors Degenerative conditions of bones in the hips, pelvis, and upper legs ... hip joint Tumors of the bones of the pelvis Sacroiliitis (inflammation of the area where the sacrum ...

  7. Chest X-Ray

    Medline Plus

    Full Text Available ... and use a very small dose of ionizing radiation to produce pictures of the inside of the ... x-ray use a tiny dose of ionizing radiation, the benefit of an accurate diagnosis far outweighs ...

  8. Chest X-Ray

    Medline Plus

    Full Text Available ... Index A-Z Spotlight October is National Breast Cancer Awareness Month Recently posted: Medical Imaging Costs Magnetoencephalography ( ... of lung conditions such as pneumonia, emphysema and cancer. A chest x-ray requires no special preparation. ...

  9. Chest X-Ray

    Medline Plus

    Full Text Available ... chest x-ray is used to evaluate the lungs, heart and chest wall and may be used ... diagnose and monitor treatment for a variety of lung conditions such as pneumonia, emphysema and cancer. A ...

  10. X-ray - skeleton

    Science.gov (United States)

    ... x-ray particles pass through the body. A computer or special film records the images. Structures that ... M. is also a founding member of Hi-Ethics and subscribes to the principles of the Health ...

  11. X-Ray Diffraction.

    Science.gov (United States)

    Smith, D. K.; Smith, K. L.

    1980-01-01

    Reviews applications in research and analytical characterization of compounds and materials in the field of X-ray diffraction, emphasizing new developments in applications and instrumentation in both single crystal and powder diffraction. Cites 414 references. (CS)

  12. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  13. X-Ray Diffraction.

    Science.gov (United States)

    Smith, D. K.; Smith, K. L.

    1980-01-01

    Reviews applications in research and analytical characterization of compounds and materials in the field of X-ray diffraction, emphasizing new developments in applications and instrumentation in both single crystal and powder diffraction. Cites 414 references. (CS)

  14. Chest X-Ray

    Medline Plus

    Full Text Available ... breath, persistent cough, fever, chest pain or injury. It may also be useful to help diagnose and ... have some concerns about chest x-rays. However, it’s important to consider the likelihood of benefit to ...

  15. Chest X-Ray

    Medline Plus

    Full Text Available ... CT Angiography Video: Myelography Video: CT of the Heart Video: Radioiodine I-131 Therapy Radiology and You ... x-ray is used to evaluate the lungs, heart and chest wall and may be used to ...

  16. X-rays and magnetism.

    Science.gov (United States)

    Fischer, Peter; Ohldag, Hendrik

    2015-09-01

    Magnetism is among the most active and attractive areas in modern solid state physics because of intriguing phenomena interesting to fundamental research and a manifold of technological applications. State-of-the-art synthesis of advanced magnetic materials, e.g. in hybrid structures paves the way to new functionalities. To characterize modern magnetic materials and the associated magnetic phenomena, polarized x-rays have emerged as unique probes due to their specific interaction with magnetic materials. A large variety of spectroscopic and microscopic techniques have been developed to quantify in an element, valence and site-sensitive way properties of ferro-, ferri-, and antiferromagnetic systems, such as spin and orbital moments, and to image nanoscale spin textures and their dynamics with sub-ns time and almost 10 nm spatial resolution. The enormous intensity of x-rays and their degree of coherence at next generation x-ray facilities will open the fsec time window to magnetic studies addressing fundamental time scales in magnetism with nanometer spatial resolution. This review will give an introduction into contemporary topics of nanoscale magnetic materials and provide an overview of analytical spectroscopy and microscopy tools based on x-ray dichroism effects. Selected examples of current research will demonstrate the potential and future directions of these techniques.

  17. Observation of femtosecond X-ray interactions with matter using an X-ray-X-ray pump-probe scheme.

    Science.gov (United States)

    Inoue, Ichiro; Inubushi, Yuichi; Sato, Takahiro; Tono, Kensuke; Katayama, Tetsuo; Kameshima, Takashi; Ogawa, Kanade; Togashi, Tadashi; Owada, Shigeki; Amemiya, Yoshiyuki; Tanaka, Takashi; Hara, Toru; Yabashi, Makina

    2016-02-01

    Resolution in the X-ray structure determination of noncrystalline samples has been limited to several tens of nanometers, because deep X-ray irradiation required for enhanced resolution causes radiation damage to samples. However, theoretical studies predict that the femtosecond (fs) durations of X-ray free-electron laser (XFEL) pulses make it possible to record scattering signals before the initiation of X-ray damage processes; thus, an ultraintense X-ray beam can be used beyond the conventional limit of radiation dose. Here, we verify this scenario by directly observing femtosecond X-ray damage processes in diamond irradiated with extraordinarily intense (∼10(19) W/cm(2)) XFEL pulses. An X-ray pump-probe diffraction scheme was developed in this study; tightly focused double-5-fs XFEL pulses with time separations ranging from sub-fs to 80 fs were used to excite (i.e., pump) the diamond and characterize (i.e., probe) the temporal changes of the crystalline structures through Bragg reflection. It was found that the pump and probe diffraction intensities remain almost constant for shorter time separations of the double pulse, whereas the probe diffraction intensities decreased after 20 fs following pump pulse irradiation due to the X-ray-induced atomic displacement. This result indicates that sub-10-fs XFEL pulses enable conductions of damageless structural determinations and supports the validity of the theoretical predictions of ultraintense X-ray-matter interactions. The X-ray pump-probe scheme demonstrated here would be effective for understanding ultraintense X-ray-matter interactions, which will greatly stimulate advanced XFEL applications, such as atomic structure determination of a single molecule and generation of exotic matters with high energy densities.

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... holds the x-ray film or image recording plate . Sometimes the x-ray is taken with the ... an x-ray film holder or image recording plate is placed beneath the patient. top of page ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) ... diagnosis and disease management. top of page How is the procedure performed? The technologist, an individual specially ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... holds the x-ray film or image recording plate . Sometimes the x-ray is taken with the ... an x-ray film holder or image recording plate is placed beneath the patient. top of page ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... drawer under the table holds the x-ray film or image recording plate . Sometimes the x-ray ... extended over the patient while an x-ray film holder or image recording plate is placed beneath ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... that might interfere with the x-ray images. Women should always inform their physician and x-ray ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  3. Atomic holography with electrons and x-rays: Theoretical and experimental studies

    Energy Technology Data Exchange (ETDEWEB)

    Len, Patrick Michael [Univ. of California, Davis, CA (United States). Dept. of Physics

    1997-06-01

    Gabor first proposed holography in 1948 as a means to experimentally record the amplitude and phase of scattered wavefronts, relative to a direct unscattered wave, and to use such a "hologram" to directly image atomic structure. But imaging at atomic resolution has not yet been possible in the way he proposed. Much more recently, Szoeke in 1986 noted that photoexcited atoms can emit photoelectron of fluorescent x-ray wavefronts that are scattered by neighboring atoms, thus yielding the direct and scattered wavefronts as detected in the far field that can then be interpreted as holographic in nature. By now, several algorithms for directly reconstructing three-dimensional atomic images from electron holograms have been proposed (e.g. by Barton) and successfully tested against experiment and theory. Very recently, Tegze and Faigel, and Grog et al. have recorded experimental x-ray fluorescence holograms, and these are found to yield atomic images that are more free of the kinds of aberrations caused by the non-ideal emission or scattering of electrons. The basic principles of these holographic atomic imaging methods are reviewed, including illustrative applications of the reconstruction algorithms to both theoretical and experimental electron and x-ray holograms. The author also discusses the prospects and limitations of these newly emerging atomic structural probes.

  4. Direct navigation on 3D rotational x-ray data acquired with a mobile propeller C-arm: accuracy and application in functional endoscopic sinus surgery.

    Science.gov (United States)

    van de Kraats, Everine B; Carelsen, Bart; Fokkens, Wytske J; Boon, Sjirk N; Noordhoek, Niels; Niessen, Wiro J; van Walsum, Theo

    2005-12-21

    Recently, three-dimensional (3D) rotational x-ray imaging has been combined with navigation technology, enabling direct 3D navigation for minimally invasive image guided interventions. In this study, phantom experiments are used to determine the accuracy of such a navigation set-up for a mobile C-arm with propeller motion. After calibration of the C-arm system, the accuracy is evaluated by pinpointing divots on a special-purpose phantom with known geometry. This evaluation is performed both with and without C-arm motion in between calibration and registration for navigation. The variation caused by each of the individual transformations in the calibration and registration process is also studied. The feasibility of direct navigation on 3D rotational x-ray images for functional endoscopic sinus surgery has been evaluated in a cadaver navigation experiment. Navigation accuracy was approximately 1.0 mm, which is sufficient for functional endoscopic sinus surgery. C-arm motion in between calibration and registration slightly degraded the registration accuracy by approximately 0.3 mm. Standard deviations of each of the transformations were in the range 0.15-0.31 mm. In the cadaver experiment, the navigation images were considered in good correspondence with the endoscopic images by an experienced ENT surgeon. Availability of 3D localization information provided by the navigation system was considered valuable by the ENT surgeon.

  5. Direct navigation on 3D rotational x-ray data acquired with a mobile propeller C-arm: accuracy and application in functional endoscopic sinus surgery

    Science.gov (United States)

    van de Kraats, Everine B.; Carelsen, Bart; Fokkens, Wytske J.; Boon, Sjirk N.; Noordhoek, Niels; Niessen, Wiro J.; van Walsum, Theo

    2005-12-01

    Recently, three-dimensional (3D) rotational x-ray imaging has been combined with navigation technology, enabling direct 3D navigation for minimally invasive image guided interventions. In this study, phantom experiments are used to determine the accuracy of such a navigation set-up for a mobile C-arm with propeller motion. After calibration of the C-arm system, the accuracy is evaluated by pinpointing divots on a special-purpose phantom with known geometry. This evaluation is performed both with and without C-arm motion in between calibration and registration for navigation. The variation caused by each of the individual transformations in the calibration and registration process is also studied. The feasibility of direct navigation on 3D rotational x-ray images for functional endoscopic sinus surgery has been evaluated in a cadaver navigation experiment. Navigation accuracy was approximately 1.0 mm, which is sufficient for functional endoscopic sinus surgery. C-arm motion in between calibration and registration slightly degraded the registration accuracy by approximately 0.3 mm. Standard deviations of each of the transformations were in the range 0.15-0.31 mm. In the cadaver experiment, the navigation images were considered in good correspondence with the endoscopic images by an experienced ENT surgeon. Availability of 3D localization information provided by the navigation system was considered valuable by the ENT surgeon.

  6. Direct navigation on 3D rotational x-ray data acquired with a mobile propeller C-arm: accuracy and application in functional endoscopic sinus surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kraats, Everine B van de [Image Sciences Institute, University Medical Center Utrecht (Netherlands); Carelsen, Bart [Academic Medical Center Amsterdam, Medical Physics Department (Netherlands); Fokkens, Wytske J [Academic Medical Center Amsterdam, Department of Otorhinolaryngology (Netherlands); Boon, Sjirk N [Philips Medical Systems, Best (Netherlands); Noordhoek, Niels [Philips Medical Systems, Best (Netherlands); Niessen, Wiro J [Image Sciences Institute, University Medical Center Utrecht (Netherlands); Walsum, Theo van [Image Sciences Institute, University Medical Center Utrecht (Netherlands)

    2005-12-21

    Recently, three-dimensional (3D) rotational x-ray imaging has been combined with navigation technology, enabling direct 3D navigation for minimally invasive image guided interventions. In this study, phantom experiments are used to determine the accuracy of such a navigation set-up for a mobile C-arm with propeller motion. After calibration of the C-arm system, the accuracy is evaluated by pinpointing divots on a special-purpose phantom with known geometry. This evaluation is performed both with and without C-arm motion in between calibration and registration for navigation. The variation caused by each of the individual transformations in the calibration and registration process is also studied. The feasibility of direct navigation on 3D rotational x-ray images for functional endoscopic sinus surgery has been evaluated in a cadaver navigation experiment. Navigation accuracy was approximately 1.0 mm, which is sufficient for functional endoscopic sinus surgery. C-arm motion in between calibration and registration slightly degraded the registration accuracy by approximately 0.3 mm. Standard deviations of each of the transformations were in the range 0.15-0.31 mm. In the cadaver experiment, the navigation images were considered in good correspondence with the endoscopic images by an experienced ENT surgeon. Availability of 3D localization information provided by the navigation system was considered valuable by the ENT surgeon.

  7. X-Ray Absorption with Transmission X-Ray Microscopes

    NARCIS (Netherlands)

    de Groot, F.M.F.

    2016-01-01

    In this section we focus on the use of transmission X-ray microscopy (TXM) to measure the XAS spectra. In the last decade a range of soft X-ray and hard X-ray TXM microscopes have been developed, allowing the measurement of XAS spectra with 10–100 nm resolution. In the hard X-ray range the TXM

  8. Perspectives of medical X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Freudenberger, J. E-mail: joerg.freudenberger@med.siemens.de; Hell, E.; Knuepfer, W

    2001-06-21

    While X-ray image intensifiers (XII), storage phosphor screens and film-screen systems are still the work horses of medical imaging, large flat panel solid state detectors using either scintillators and amorphous silicon photo diode arrays (FD-Si), or direct X-ray conversion in amorphous selenium are reaching maturity. The main advantage with respect to image quality and low patient dose of the XII and FD-Si systems is caused by the rise of the Detector Quantum Efficiency originating from the application of thick needle-structured phosphor X-ray absorbers. With the detectors getting closer to an optimal state, further progress in medical X-ray imaging requires an improvement of the usable source characteristics. The development of clinical monochromatic X-ray sources of high power would not only allow an improved contrast-to-dose ratio by allowing smaller average photon energies in applications but would also lead to new imaging techniques.

  9. Perspectives of medical X-ray imaging

    Science.gov (United States)

    Freudenberger, J.; Hell, E.; Knüpfer, W.

    2001-06-01

    While X-ray image intensifiers (XII), storage phosphor screens and film-screen systems are still the work horses of medical imaging, large flat panel solid state detectors using either scintillators and amorphous silicon photo diode arrays (FD-Si), or direct X-ray conversion in amorphous selenium are reaching maturity. The main advantage with respect to image quality and low patient dose of the XII and FD-Si systems is caused by the rise of the Detector Quantum Efficiency originating from the application of thick needle-structured phosphor X-ray absorbers. With the detectors getting closer to an optimal state, further progress in medical X-ray imaging requires an improvement of the usable source characteristics. The development of clinical monochromatic X-ray sources of high power would not only allow an improved contrast-to-dose ratio by allowing smaller average photon energies in applications but would also lead to new imaging techniques.

  10. X-ray Pulsars

    CERN Document Server

    Walter, Roland

    2016-01-01

    X-ray pulsars shine thanks to the conversion of the gravitational energy of accreted material to X-ray radiation. The accretion rate is modulated by geometrical and hydrodynamical effects in the stellar wind of the pulsar companions and/or by instabilities in accretion discs. Wind driven flows are highly unstable close to neutron stars and responsible for X-ray variability by factors $10^3$ on time scale of hours. Disk driven flows feature slower state transitions and quasi periodic oscillations related to orbital motion and precession or resonance. On shorter time scales, and closer to the surface of the neutron star, X-ray variability is dominated by the interactions of the accreting flow with the spinning magnetosphere. When the pulsar magnetic field is large, the flow is confined in a relatively narrow accretion column, whose geometrical properties drive the observed X-ray emission. In low magnetized systems, an increasing accretion rate allows the ignition of powerful explosive thermonuclear burning at t...

  11. Direct Observation of Phase Transformations in Austenitic Stainless Steel Welds Using In-situ Spatially Resolved and Time-resolved X-ray Diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Elmer, J.; Wong, J.; Ressler, T.

    1999-09-23

    Spatially resolved x-ray diffraction (SRXRD) and time resolved x-ray diffraction (TRXRD) were used to investigate real time solid state phase transformations and solidification in AISI type 304 stainless steel gas tungsten arc (GTA) welds. These experiments were conducted at Stanford Synchrotron Radiation Laboratory (SSRL) using a high flux beam line. Spatially resolved observations of {gamma} {leftrightarrow} {delta} solid state phase transformations were performed in the heat affected zone (HAZ) of moving welds and time-resolved observations of the solidification sequence were performed in the fusion zone (FZ) of stationary welds after the arc had been terminated. Results of the moving weld experiments showed that the kinetics of the {gamma}{yields}{delta} phase transformation on heating in the HAZ were sufficiently rapid to transform a narrow region surrounding the liquid weld pool to the {delta} ferrite phase. Results of the stationary weld experiments showed, for the first time, that solidification can occur directly to the {delta} ferrite phase, which persisted as a single phase for 0.5s. Upon solidification to {delta}, the {delta} {yields} {gamma} phase transformation followed and completed in 0.2s as the weld cooled further to room temperature.

  12. Direct mapping of 19F in 19FDG-6P in brain tissue at subcellular resolution using soft X-ray fluorescence

    Science.gov (United States)

    Poitry-Yamate, C.; Gianoncelli, A.; Kourousias, G.; Kaulich, B.; Lepore, M.; Gruetter, R.; Kiskinova, M.

    2013-10-01

    Low energy x-ray fluorescence (LEXRF) detection was optimized for imaging cerebral glucose metabolism by mapping the fluorine LEXRF signal of 19F in 19FDG, trapped as intracellular 19F-deoxyglucose-6-phosphate (19FDG-6P) at 1μm spatial resolution from 3μm thick brain slices. 19FDG metabolism was evaluated in brain structures closely resembling the general cerebral cytoarchitecture following formalin fixation of brain slices and their inclusion in an epon matrix. 2-dimensional distribution maps of 19FDG-6P were placed in a cytoarchitectural and morphological context by simultaneous LEXRF mapping of N and O, and scanning transmission x-ray (STXM) imaging. A disproportionately high uptake and metabolism of glucose was found in neuropil relative to intracellular domains of the cell body of hypothalamic neurons, showing directly that neurons, like glial cells, also metabolize glucose. As 19F-deoxyglucose-6P is structurally identical to 18F-deoxyglucose-6P, LEXRF of subcellular 19F provides a link to in vivo 18FDG PET, forming a novel basis for understanding the physiological mechanisms underlying the 18FDG PET image, and the contribution of neurons and glia to the PET signal.

  13. X-rays, clumping and wind structures

    Science.gov (United States)

    Oskinova, Lidia; Hamann, Wolf-Rainer; Ignace, Richard; Feldmeier, Achim

    2011-01-01

    X-ray emission is ubiquitous among massive stars. In the last decade, X-ray observations revolutionized our perception of stellar winds but opened a Pandora's box of urgent problems. X-rays penetrating stellar winds suffer mainly continuum absorption, which greatly simplifies the radiative transfer treatment. The small and large scale structures in stellar winds must be accounted for to understand the X-ray emission from massive stars. The analysis of X-ray spectral lines can help to infer the parameters of wind clumping, which is prerequisite for obtaining empirically correct stellar mass-loss rates. The imprint of large scale structures, such as CIRs and equatorial disks, on the X-ray emission is predicted, and new observations are testing theoretical expectations. The X-ray emission from magnetic stars proves to be more diverse than anticipated from the direct application of the magnetically-confined wind model. Many outstanding questions about X-rays from massive stars will be answered when the models and the observations advance.

  14. Core Perylene Diimide Designs via Direct Bay and Ortho (Poly)trifluoromethylation: Synthesis, Isolation, X-ray Structures, Optical and Electronic Properties

    Energy Technology Data Exchange (ETDEWEB)

    Clikeman, Tyler T.; Bukovsky, Eric V.; Wang, Xue B.; Chen, Yu-Sheng; Rumbles, Garry; Strauss, Steven H.; Boltalina, Olga V.

    2015-09-22

    We developed an efficient solvent- and catalyst-free direct polytrifluoromethylation of solid perylene-3,4,9,10-tetracarboxylic dianhydride that produced a new family of (poly)perfluoroalkyl bay and ortho substituted PDIs with two different imide substituents. Direct hydrogen substitution with CN group led to the synthesis of a cyanated perfluoroalkyl PDI derivative for the first time. Absorption, steady-state and time-resolved emission, X-ray diffraction, electrochemical, and gas-phase electron affinity data allowed for systematic studies of substitution effects at bay, ortho, and imide positions in the new PDIs. Solid-state packing showed remarkable variations in the intermolecular interactions that are important for charge transport and photophysical properties. Analysis of the electrochemical data for 143 electron poor PDIs, including newly reported compounds, revealed some general trends and peculiar effects of electron withdrawing group substitution at all three positions.

  15. Core Perylene Diimide Designs via Direct Bay- and ortho-(Poly)trifluoromethylation: Synthesis, Isolation, X-Ray Structures, Optical and Electronic Properties

    Energy Technology Data Exchange (ETDEWEB)

    Clikeman, Tyler T. [Colorado State Univ., Fort Collins, CO (United States); Bukovsky, Eric V. [Colorado State Univ., Fort Collins, CO (United States); Wang, Xue-Bin [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chen, Yu-Sheng [Univ. of Chicago, IL (United States); Rumbles, Garry [National Renewable Energy Lab. (NREL), Golden, CO (United States); Strauss, Steven H. [Colorado State Univ., Fort Collins, CO (United States); Boltalina, Olga V. [Colorado State Univ., Fort Collins, CO (United States)

    2015-09-22

    We developed an efficient solvent- and catalyst-free direct polytrifluoromethylation of solid perylene-3,4,9,10-tetracarboxylic dianhydride that produced a new family of (poly)perfluoroalkyl bay- and ortho-substituted PDIs with two different imide substituents. Direct hydrogen substitution with CN group led to the synthesis of a cyanated perfluoroalkyl PDI derivative for the first time. Absorption, steady-state and time-resolved emission, X-ray diffraction, electrochemical, and gas-phase electron affinity data allowed for systematic studies of substitution effects at bay, ortho, and imide positions in the new PDIs. Solid-state packing showed remarkable variations in the intermolecular interactions that are important for charge transport and photophysical properties. Moreover, analysis of the electrochemical data for 143 electron poor PDIs, including newly reported compounds, revealed some general trends and peculiar effects from substituting electron-withdrawing groups at all three positions.

  16. X-Ray Protection

    Science.gov (United States)

    1955-01-01

    15,000. • When developed In Kodak liquid X-ray developer for 5 min at a temperature of 200 C. b Film sensitivities vary with photon energy by the...for example temporomandibular -joint exposures where a skin dose of 25 r or more may be obtained during a single exposure with 65 kvp, 1.5 mm aluminum...communication. W. J. Updegrave, Temporomandibular articulation-X-ray examina- tion, Dental Radiography and Photography 26, No. 3, 41 (1953). H. 0. Wyckoff, R. J

  17. X-ray Reflection

    Science.gov (United States)

    Fabian, A. C.; Ross, R. R.

    2010-12-01

    Material irradiated by X-rays produces backscattered radiation which is commonly known as the Reflection Spectrum. It consists of a structured continuum, due at high energies to the competition between photoelectric absorption and electron scattering enhanced at low energies by emission from the material itself, together with a complex line spectrum. We briefly review the history of X-ray reflection in astronomy and discuss various methods for computing the reflection spectrum from cold and ionized gas, illustrated with results from our own work reflionx. We discuss how the reflection spectrum can be used to obtain the geometry of the accretion flow, particularly the inner regions around black holes and neutron stars.

  18. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a very small dose of ... x-ray , is a two-dimensional (2-D) dental x-ray examination that captures the entire mouth ...

  19. Direct laser writing defects in holographic lithography-created photonic lattices.

    Science.gov (United States)

    Sun, Hong-Bo; Nakamura, Atsushi; Kaneko, Koshiro; Shoji, Satoru; Kawata, Satoshi

    2005-04-15

    As a well-established laser fabrication approach, holographic lithography, or multibeam interference patterning, is known for its capability to create long-range ordered large-volume photonic crystals (PhCs) rapidly. Its broad use is, however, hampered by difficulty in inducing artificially designed defects for device functions. We use pinpoint femtosecond laser ablation to remove and two-photon photopolymerization to add desired defective features to obtain photonic acceptors and photonic donors, respectively, in an otherwise complete PhC matrix produced by holographic lithography. The combined use of the two direct laser writing technologies would immediately make holographic lithography a promising industrial tool for PhC manufacture.

  20. Chest X-Ray

    Medline Plus

    Full Text Available ... Therapy November 8 is the International Day of Radiology (IDoR) Radiology and You Sponsored by Image/Video Gallery Your Radiologist Explains Chest X-ray Transcript Welcome to Radiology Info dot org! Hello, I’m Dr. Geoffrey ...

  1. X-ray structure at 1.75 resolution of a norovirus 3C protease linked to an active site-directed peptide inhibitor

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Jon [University of Southampton, England; Coates, Leighton [ORNL; Hussey, Robert [University of Southampton, England

    2010-01-01

    Noroviruses are recognized universally as the most important cause of human epidemic non-bacterial gastroenteritis. Viral replication requires a 3C cysteine protease that cleaves a 200kDa viral polyprotein into its constituent functional proteins. Here we describe the X-ray structure of the Southampton norovirus 3C protease (SV3CP) bound to an active site-directed peptide inhibitor (MAPI) which has been refined at 1.75 resolution, following initial MAD phasing with a selenomethionine derivative. The inhibitor, acetyl-Glu-Phe-Gln-Leu-Gln-X, based on a 3C protease cleavage recognition sequences in the 200kDa polyprotein substrate, reacts covalently through its propenylethylester group (X) with the active site nucleophile, Cys 139. The 3C protease-inhibitor structure permits, for the first time, the identification of substrate recognition and binding groups and provides important new information for the development of antiviral prophylactics.

  2. A Monte Carlo study of x-ray fluorescence in x-ray detectors.

    Science.gov (United States)

    Boone, J M; Seibert, J A; Sabol, J M; Tecotzky, M

    1999-06-01

    Advances in digital x-ray detector systems have led to a renewed interest in the performance of x-ray phosphors and other detector materials. Indirect flat panel x-ray detector and charged coupled device (CCD) systems require a more technologically challenging geometry, whereby the x-ray beam is incident on the front side of the scintillator, and the light produced must diffuse to the back surface of the screen to reach the photoreceptor. Direct detector systems based on selenium have also enjoyed a growing interest, both commercially and academically. Monte Carlo simulation techniques were used to study the x-ray scattering (Rayleigh and Compton) and the more prevalent x-ray fluorescence properties of seven different x-ray detector materials, Gd2O2S, CsI, Se, BaFBr, YTaO4, CaWO4, and ThO2. The redistribution of x-ray energy, back towards the x-ray source, in a forward direction through the detector, and lateral reabsorption in the detector was computed under monoenergetic conditions (1 keV to 130 keV by 1 keV intervals) with five detector thicknesses, 30, 60, 90, 120, and 150 mg/cm2 (Se was studied from 30 to 1000 mg/cm2). The radial distribution (related to the point spread function) of reabsorbed x-ray energy was also determined. Representative results are as follows: At 55 keV, more (31.3%) of the incident x-ray energy escaped from a 90 mg/cm2Gd2O2S detector than was absorbed (27.9%). Approximately 1% of the total absorbed energy was reabsorbed greater than 0.5 mm from the primary interaction, for 90 mg/cm2 CsI exposed at 100 kVp. The ratio of reabsorbed secondary (fluorescence + scatter) radiation to the primary radiation absorbed in the detectors (90 mg/cm2) (S/P) was determined as 10%, 16%, 2%, 12%, 3%, 3%, and 0.3% for a 100 kVp tungsten anode x-ray spectrum, for the Gd2O2S, CsI, Se, BaFBr, YTaO4, CaWO4, and ThO2 detectors, respectively. The results indicate significant x-ray fluorescent escape and reabsorption in common x-ray detectors. These findings

  3. Do the results of respirable dust samples obtained from direct-on-filter X-ray diffraction, direct-on-filter infrared and indirect infrared (KBr pellet) methods correlate?

    CSIR Research Space (South Africa)

    Pretorius, C

    2010-11-01

    Full Text Available determines how the dust is distributed on the filter (analysis area of XRD vs FTIR). Current research Acknowledgements The Mine Health and Safety Council (MHSC) of South Africa provided the funding for this research project (SIM 080601) References 1.... ?MDHS 101. Direct-on-filter analysis by infrared spectroscopy and X-ray diffraction?, February 2005, Health and Safety Laboratory: Methods for the Determination of Hazardous Substances. 2. Occupational Health and Safety Administration (OSHA), Quartz...

  4. X-Ray Astronomy

    Science.gov (United States)

    Wu, S. T.

    2000-01-01

    Dr. S. N. Zhang has lead a seven member group (Dr. Yuxin Feng, Mr. XuejunSun, Mr. Yongzhong Chen, Mr. Jun Lin, Mr. Yangsen Yao, and Ms. Xiaoling Zhang). This group has carried out the following activities: continued data analysis from space astrophysical missions CGRO, RXTE, ASCA and Chandra. Significant scientific results have been produced as results of their work. They discovered the three-layered accretion disk structure around black holes in X-ray binaries; their paper on this discovery is to appear in the prestigious Science magazine. They have also developed a new method for energy spectral analysis of black hole X-ray binaries; four papers on this topics were presented at the most recent Atlanta AAS meeting. They have also carried Monte-Carlo simulations of X-ray detectors, in support to the hardware development efforts at Marshall Space Flight Center (MSFC). These computation-intensive simulations have been carried out entirely on the computers at UAH. They have also carried out extensive simulations for astrophysical applications, taking advantage of the Monte-Carlo simulation codes developed previously at MSFC and further improved at UAH for detector simulations. One refereed paper and one contribution to conference proceedings have been resulted from this effort.

  5. X-ray lithography masking

    Science.gov (United States)

    Smith, Henry I. (Inventor); Lim, Michael (Inventor); Carter, James (Inventor); Schattenburg, Mark (Inventor)

    1998-01-01

    X-ray masking apparatus includes a frame having a supporting rim surrounding an x-ray transparent region, a thin membrane of hard inorganic x-ray transparent material attached at its periphery to the supporting rim covering the x-ray transparent region and a layer of x-ray opaque material on the thin membrane inside the x-ray transparent region arranged in a pattern to selectively transmit x-ray energy entering the x-ray transparent region through the membrane to a predetermined image plane separated from the layer by the thin membrane. A method of making the masking apparatus includes depositing back and front layers of hard inorganic x-ray transparent material on front and back surfaces of a substrate, depositing back and front layers of reinforcing material on the back and front layers, respectively, of the hard inorganic x-ray transparent material, removing the material including at least a portion of the substrate and the back layers of an inside region adjacent to the front layer of hard inorganic x-ray transparent material, removing a portion of the front layer of reinforcing material opposite the inside region to expose the surface of the front layer of hard inorganic x-ray transparent material separated from the inside region by the latter front layer, and depositing a layer of x-ray opaque material on the surface of the latter front layer adjacent to the inside region.

  6. Influence of angle's ranges for recording an X-ray fluorescence hologram on reconstructed atomic images

    Institute of Scientific and Technical Information of China (English)

    XIE Hong-Lan; CHEN Jian-Wen; GAO Hong-Yi; ZHU Hua-Feng; LI Ru-Xin; XU Zhi-Zhan

    2004-01-01

    X-ray fluorescence holography (XFH) is a novel method for three-dimensional (3D) imaging of atomic structure. Theoretically, in an XFH experiment, one has to measure the fluorescence energy on a spherical surface to get well-resolved 3D images of atoms. But in practice, the experimental system arrangement does not allow the measurement of the fluorescent intensity oscillations in the full sphere. The holographic information losses because of the limited sampling range (less than 4π) will directly result in defective reconstructed atomic images. In this work, the atomic image of a Fe single crystal (001) was reconstructed by numerically simulating X-ray fluorescence holograms of the crystal at different recording angle's ranges and step lengths. Influences of the ranges of azimuth angles and polar angles and the step length of polar angles on the reconstructed atomic images were discussed.

  7. Production of the laminar gratings in the VUV and soft x-ray region

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Makoto; Sasai, Hiroyuki; Sano, Kazuo; Harada, Yoshihisa [Shimadzu Corp., Production Engineering Laboratory, Kyoto (Japan)

    2000-03-01

    The appearance of third-generation synchrotron radiation sources has demanded the high performance grazing-incidence monochromators for VUV and soft x-ray region. Also the diffraction gratings which were optical elements have been required the characteristic of high heat-resistant, well cooling, with a large size and low-micro- roughness. In this paper, how to product of the laming gratings by means of holographic exposure method and ion-beam etching technology, with direct etched in the silicon crystal blank are reviewed. (author)

  8. X-ray diffraction contrast tomography (DCT) system, and an X-ray diffraction contrast tomography (DCT) method

    DEFF Research Database (Denmark)

    2012-01-01

    Source: US2012008736A An X-ray diffraction contrast tomography system (DCT) comprising a laboratory X-ray source (2), a staging device (5) rotating a polycrystalline material sample in the direct path of the X-ray beam, a first X-ray detector (6) detecting the direct X-ray beam being transmitted ...... in the polycrystalline sample is determined based on the two-dimensional position of extinction spots and the associated angular position of the sample for a set of extinction spots pertaining to the individual grain....

  9. Nonrelativistic quantum X-ray physics

    CERN Document Server

    Hau-Riege, Stefan P

    2015-01-01

    Providing a solid theoretical background in photon-matter interaction, Nonrelativistic Quantum X-Ray Physics enables readers to understand experiments performed at XFEL-facilities and x-ray synchrotrons. As a result, after reading this book, scientists and students will be able to outline and perform calculations of some important x-ray-matter interaction processes. Key features of the contents are that the scope reaches beyond the dipole approximation when necessary and that it includes short-pulse interactions. To aid the reader in this transition, some relevant examples are discussed in detail, while non-relativistic quantum electrodynamics help readers to obtain an in-depth understanding of the formalisms and processes. The text presupposes a basic (undergraduate-level) understanding of mechanics, electrodynamics, and quantum mechanics. However, more specialized concepts in these fields are introduced and the reader is directed to appropriate references. While primarily benefiting users of x-ray light-sou...

  10. Panoramic Dental X-Ray

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Panoramic Dental X-ray Panoramic dental x-ray uses a ... Your e-mail address: Personal message (optional): Bees: Wax: Notice: RadiologyInfo respects your privacy. Information entered here ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the body. X-rays are the oldest and most frequently used form of medical imaging. A bone ... bones. top of page How should I prepare? Most bone x-rays require no special preparation. You ...

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... tissue shows up in shades of gray and air appears black. Until recently, x-ray images were ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  13. Soft X-ray Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Seely, John

    1999-05-20

    The contents of this report cover the following: (1) design of the soft x-ray telescope; (2) fabrication and characterization of the soft x-ray telescope; and (3) experimental implementation at the OMEGA laser facility.

  14. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? A bone x-ray is used to: ... and x-rays. top of page What does the equipment look like? The equipment typically used for ...

  15. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... standards used by radiology professionals. Modern x-ray systems have very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Us News Physician Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses ... assess trauma patients in emergency departments. A CT scan can image complicated fractures, subtle fractures or dislocations. ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patient. top of page How does the procedure work? X-rays are a form of radiation like ... very controlled x-ray beams and dose control methods to minimize stray (scatter) radiation. This ensures that ...

  20. Abdomen X-Ray (Radiography)

    Science.gov (United States)

    ... Professions Site Index A-Z X-ray (Radiography) - Abdomen Abdominal x-ray uses a very small dose ... to produce pictures of the inside of the abdominal cavity. It is used to evaluate the stomach, liver, ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... radiation like light or radio waves. X-rays pass through most objects, including the body. Once it ... organs, allow more of the x-rays to pass through them. As a result, bones appear white ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... position possible that still ensures x-ray image quality. top of page Who interprets the results and ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... and x-rays. A Word About Minimizing Radiation Exposure Special care is taken during x-ray examinations ... patient's body not being imaged receive minimal radiation exposure. top of page What are the limitations of ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... fracture. guide orthopedic surgery, such as spine repair/fusion, joint replacement and fracture reductions. look for injury, ... and Media Arthritis X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to X-ray ( ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? A bone x-ray is used to: ... and x-rays. top of page What does the equipment look like? The equipment typically used for ...

  6. Incommensurate modulations in Bi-2212 high-T_c superconductor revealed by single-crystal X-ray analysis using direct methods

    Institute of Scientific and Technical Information of China (English)

    付正清; 李阳; 程庭柱; 张裕恒; 顾秉林; 范海福

    1995-01-01

    The incommensurate modulated structure of the Bi2Sr2Ca1Cu2Oy high-Tc superocnductor has been studied by direct methods with X-ray diffraction data from a single crystal. The super-space group is N111Bbmb with three-dimensional unit cell parameters a = 0.54222 nm, b=0.5437 nm, c=3.0537 run, α=β=γ=90° andthemodula-tion wave vector q=(0, 0.22, 1). 543 main reflections, 867 first-order and 469 second-order satellite reflections have been observed. Phases of main reflections are derived by a conventional direct-method program SAPI91. The phases of satellite reflections are derived by the program DIMS running with default control based on the known phases of main reflections. The atomic parameters of the basic structure and of the modulation so obtained consist with the results from other authors. For the first time the structure details of the incommensurate modulation in the Bi-2212 phase are observed directly without relying on any assumed model of modulation.

  7. Doses measured using AEC on direct digital radiographic (DDR) X-rays systems: updated results with an RP 162 perspective.

    Science.gov (United States)

    Bowden, L; Faulkner, R; Gallagher, A; O'Connor, U; Walsh, C; Dowling, A; O'Reilly, G

    2013-02-01

    As digital technology in diagnostic radiology systems becomes more prevalent, there is a need to provide comparative dose information for these new systems. This is needed in particular for testing the automatic exposure control (AEC) devices on direct digital radiography (DDR) systems as there is no consensus on the receptor dose level in the current guidelines. The new European Commission RP 162 document sets the suspension level for the 'verification of kerma at receptor entrance in computed radiography and DDR systems under AEC' as ≥10 µGy. This document also notes that alternate methodologies are acceptable, and may require adjustment in the suspension level if used. This study provides a range of typical doses under AEC for DDR systems, for a variety measurement methodologies, including that described in RP 162.

  8. X-Ray Exam: Hip

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Hip KidsHealth > For Parents > X-Ray Exam: Hip A A A What's in ... español Radiografía: cadera What It Is A hip X-ray is a safe and painless test that ...

  9. X-Ray Exam: Finger

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Finger KidsHealth > For Parents > X-Ray Exam: Finger A A A What's in ... español Radiografía: dedo What It Is A finger X-ray is a safe and painless test that ...

  10. X-Ray Exam: Foot

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Foot KidsHealth > For Parents > X-Ray Exam: Foot A A A What's in ... español Radiografía: pie What It Is A foot X-ray is a safe and painless test that ...

  11. X-Ray Exam: Wrist

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Wrist KidsHealth > For Parents > X-Ray Exam: Wrist A A A What's in ... español Radiografía: muñeca What It Is A wrist X-ray is a safe and painless test that ...

  12. X-Ray Exam: Ankle

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Ankle KidsHealth > For Parents > X-Ray Exam: Ankle A A A What's in ... español Radiografía: tobillo What It Is An ankle X-ray is a safe and painless test that ...

  13. X-Ray Exam: Pelvis

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Pelvis KidsHealth > For Parents > X-Ray Exam: Pelvis A A A What's in ... español Radiografía: pelvis What It Is A pelvis X-ray is a safe and painless test that ...

  14. X-Ray Exam: Forearm

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Forearm KidsHealth > For Parents > X-Ray Exam: Forearm A A A What's in ... español Radiografía: brazo What It Is A forearm X-ray is a safe and painless test that ...

  15. X-ray selected BALQSOs

    CERN Document Server

    Page, M J; Ceballos, M; Corral, A; Ebrero, J; Esquej, P; Krumpe, M; Mateos, S; Rosen, S; Schwope, A; Streblyanska, A; Symeonidis, M; Tedds, J A; Watson, M G

    2016-01-01

    We study a sample of six X-ray selected broad absorption line (BAL) quasi-stellar objects (QSOs) from the XMM-Newton Wide Angle Survey. All six objects are classified as BALQSOs using the classic balnicity index, and together they form the largest sample of X-ray selected BALQSOs. We find evidence for absorption in the X-ray spectra of all six objects. An ionized absorption model applied to an X-ray spectral shape that would be typical for non-BAL QSOs (a power law with energy index alpha=0.98) provides acceptable fits to the X-ray spectra of all six objects. The optical to X-ray spectral indices, alpha_OX, of the X-ray selected BALQSOs, have a mean value of 1.69 +- 0.05, which is similar to that found for X-ray selected and optically selected non-BAL QSOs of similar ultraviolet luminosity. In contrast, optically-selected BALQSOs typically have much larger alpha_OX and so are characterised as being X-ray weak. The results imply that X-ray selection yields intrinsically X-ray bright BALQSOs, but their X-ray sp...

  16. X-ray Crystallography Facility

    Science.gov (United States)

    2000-01-01

    Edward Snell, a National Research Council research fellow at NASA's Marshall Space Flight Center (MSFC), prepares a protein crystal for analysis by x-ray crystallography as part of NASA's structural biology program. The small, individual crystals are bombarded with x-rays to produce diffraction patterns, a map of the intensity of the x-rays as they reflect through the crystal.

  17. X-ray Polarization from High Mass X-ray Binaries

    CERN Document Server

    Kallman, T; Blondin, J

    2015-01-01

    X-ray astronomy allows study of objects which may be associated with compact objects, i.e. neutron stars or black holes, and also may contain strong magnetic fields. Such objects are categorically non-spherical, and likely non-circular when projected on the sky. Polarization allows study of such geoemetric effects, and X-ray polarimetry is likely to become feasible for a significant number of sources in the future. A class of potential targets for future X-ray polarization observations is the high mass X-ray binaries (HMXBs), which consist of a compact object in orbit with an early type star. In this paper ws show that X-ray polarization from HMXBs has a distinct signature which depends on the source inclination and orbital phase. The presence of the X-ray source displaced from the star creates linear polarization even if the primary wind is spherically symmetric whenever the system is viewed away from conjunction. Direct X-rays dilute this polarization whenever the X-ray source is not eclipsed; at mid-eclips...

  18. Steroid hormones partition to distinct sites in a model membrane bilayer: direct demonstration by small-angle X-ray diffraction.

    Science.gov (United States)

    Golden, G A; Rubin, R T; Mason, R P

    1998-01-19

    The classical, genomic mechanisms of steroid hormone action cannot account for their rapid cellular effects. Membrane-bound steroid receptors have been partially characterized, but many rapid steroid effects occur in the absence of steroid-protein binding. Although it has been proposed that these effects could be due to steroid-induced biophysical alterations of the cell membrane, only indirect supporting evidence for this hypothesis has been forthcoming. In the present study, the ability of cortisol and estradiol (E2), natural steroids of different lipophilicity, to induce alterations in a model membrane (lecithin) bilayer was examined directly by small-angle X-ray diffraction under physiologic-like conditions. Within minutes, both steroids partitioned to distinct sites in the membrane. With increasing membrane cholesterol content, cortisol was displaced toward the polar headgroup region of the phospholipid bilayer, whereas E2 was displaced in the opposite direction, toward the nonpolar hydrocarbon core. Membrane-based partition coefficients (Kp[mem]) for both steroids (>100:1) were highest at those cholesterol concentrations that displaced the steroids toward the headgroup region (high cholesterol for cortisol; low for E2). Both steroids, when located in the headgroup region, increased overall bilayer width by 3-4 A, a change that could modulate the structure and function of integral membrane proteins independent from steroid effects on the genome.

  19. SMM x ray polychromator

    Science.gov (United States)

    Saba, J. L. R.

    1993-01-01

    The objective of the X-ray Polychromator (XRP) experiment was to study the physical properties of solar flare plasma and its relation to the parent active region to understand better the flare mechanism and related solar activity. Observations were made to determine the temperature, density, and dynamic structure of the pre-flare and flare plasma as a function of wavelength, space and time, the extent to which the flare plasma departs from thermal equilibrium, and the variation of this departure with time. The experiment also determines the temperature and density structure of active regions and flare-induced changes in the regions.

  20. X-ray today

    Energy Technology Data Exchange (ETDEWEB)

    Neitzel, U. [Philips Medical Systems, Hamburg (Germany)

    2001-09-01

    The interest attracted by the new imaging modalities tends to overshadow the continuing importance of projection radiography and fluoroscopy. Nevertheless, projection techniques still represent by far the greatest proportion of diagnostic imaging examinations, and play an essential role in the growing number of advanced interventional procedures. This article describes some of the latest developments in X-ray imaging technology, using two products from the Philips range as examples: the Integris Allura cardiovascular system with 3D image reconstruction, and the BV Pulsera: a high-end, multi-functional mobile C-arm system with cardiac capabilities. (orig.)

  1. Elliptical X-Ray Spot Measurement

    CERN Document Server

    Richardson, R A; Weir, J T; Richardson, Roger A.; Sampayan, Stephen; Weir, John T.

    2000-01-01

    The so-called roll bar measurement uses a heavy metal material, optically thick to x-rays, to form a shadow of the x-ray origination spot. This spot is where an energetic electron beam interacts with a high Z target. The material (the "roll bar") is slightly curved to avoid alignment problems. The roll bar is constructed and positioned so that the x-rays are shadowed in the horizontal and vertical directions, so information is obtained in two dimensions. If a beam profile is assumed (or measured by other means), the equivalent x-ray spot size can be calculated from the x-ray shadow cast by the roll bar. Thus the ellipticity of the beam can be calculated, assuming the ellipse of the x-ray spot is aligned with the roll bar. The data is recorded using a scintillator and gated camera. Data will be presented from measurements using the ETA II induction LINAC. The accuracy of the measurement is checked using small elliptical targets.

  2. The X-ray imager on AXO

    Science.gov (United States)

    Budtz-Jørgensen, C.; Kuvvetli, I.; Westergaard, N. J.; Jonasson, P.; Reglero, V.; Eyles, C.

    2001-02-01

    DSRI has initiated a development program of CZT X-ray and gamma-ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as the so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low-power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: the X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and is dedicated to observations of X-ray generating processes in the Earth's atmosphere. Of special interest will be simultaneous optical and X-ray observations of sprites that are flashes appearing directly above an active thunderstorm system. Additional objective is a detailed mapping of the auroral X-ray and optical emission. XRI comprises a coded mask and a 20×40 cm 2 CZT detector array covering an energy range from 5 to 200 keV.

  3. Direct imaging by atomic force microscopy of surface-localized self-assembled monolayers on a cuprate superconductor and surface X-ray scattering analysis of analogous monolayers on the surface of water

    DEFF Research Database (Denmark)

    Schougaard, Steen B.; Reitzel, Niels; Bjørnholm, Thomas

    2007-01-01

    A self-assembled monolayer of CF3(CF2)(3)(CH2)(11)NH2 atop the (001) surface of the high-temperature superconductor YBa2Cu3O7-x was imaged by atomic force microscopy (AFM). The AFM images provide direct 2D-structural evidence for the epitaxial 5.5 angstrom square root 2 x root 2R45 degrees unit...... was studied by grazing-incidence X-ray diffraction and specular X-ray reflectivity. Structural differences and similarities between the water-supported and superconductor-localized monolayers are discussed....

  4. Direct Observation of Cooperative Protein Structural Dynamics of Homodimeric Hemoglobin from 100 ps to 10 ms with Pump-Probe X-ray Solution Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Hwan; Muniyappan, Srinivasan; Oang, Key Young; Kim, Jong Goo; Nozawa, Shunsuke; Sato, Tokushi; Koshihara, Shin-ya; Henning, Robert; Kosheleva, Irina; Ki, Hosung; Kim, Youngmin; Kim, Tae Wu; Kim, Jeongho; Adachi, Shin-ichi; Ihee, Hyotcherl [JS; (JSTA); (KAIST); (UC); (KEK)

    2012-05-29

    Proteins serve as molecular machines in performing their biological functions, but the detailed structural transitions are difficult to observe in their native aqueous environments in real time. For example, despite extensive studies, the solution-phase structures of the intermediates along the allosteric pathways for the transitions between the relaxed (R) and tense (T) forms have been elusive. In this work, we employed picosecond X-ray solution scattering and novel structural analysis to track the details of the structural dynamics of wild-type homodimeric hemoglobin (HbI) from the clam Scapharca inaequivalvis and its F97Y mutant over a wide time range from 100 ps to 56.2 ms. From kinetic analysis of the measured time-resolved X-ray solution scattering data, we identified three structurally distinct intermediates (I1, I2, and I3) and their kinetic pathways common for both the wild type and the mutant. The data revealed that the singly liganded and unliganded forms of each intermediate share the same structure, providing direct evidence that the ligand photolysis of only a single subunit induces the same structural change as the complete photolysis of both subunits does. In addition, by applying novel structural analysis to the scattering data, we elucidated the detailed structural changes in the protein, including changes in the heme-heme distance, the quaternary rotation angle of subunits, and interfacial water gain/loss. The earliest, R-like I1 intermediate is generated within 100 ps and transforms to the R-like I2 intermediate with a time constant of 3.2 ± 0.2 ns. Subsequently, the late, T-like I3 intermediate is formed via subunit rotation, a decrease in the heme-heme distance, and substantial gain of interfacial water and exhibits ligation-dependent formation kinetics with time constants of 730 ± 120 ns for the fully photolyzed form and 5.6 ± 0.8 μs for the partially photolyzed form. For

  5. X-ray lithography source

    Science.gov (United States)

    Piestrup, Melvin A.; Boyers, David G.; Pincus, Cary

    1991-01-01

    A high-intensity, inexpensive X-ray source for X-ray lithography for the production of integrated circuits. Foil stacks are bombarded with a high-energy electron beam of 25 to 250 MeV to produce a flux of soft X-rays of 500 eV to 3 keV. Methods of increasing the total X-ray power and making the cross section of the X-ray beam uniform are described. Methods of obtaining the desired X-ray-beam field size, optimum frequency spectrum and elminating the neutron flux are all described. A method of obtaining a plurality of station operation is also described which makes the process more efficient and economical. The satisfying of these issues makes transition radiation an exellent moderate-priced X-ray source for lithography.

  6. Direct observation of strain in InAs quantum dots and cap layer during molecular beam epitaxial growth using in situ X-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Shimomura, Kenichi; Ohshita, Yoshio; Kamiya, Itaru, E-mail: kamiya@toyota-ti.ac.jp [Toyota Technological Institute, 2-12-1 Hisakata, Tempaku, Nagoya 468-8511 (Japan); Suzuki, Hidetoshi [Faculty of Engineering, University of Miyazaki, 1-1 Gakuen Kibanadai-nishi, Miyazaki 889-2192 (Japan); Sasaki, Takuo; Takahasi, Masamitu [Quantum Beam Science Center, Japan Atomic Energy Agency, Koto 1-1-1, Sayo-cho, Hyogo 679-5148 (Japan)

    2015-11-14

    Direct measurements on the growth of InAs quantum dots (QDs) and various cap layers during molecular beam epitaxy are performed by in situ X-ray diffraction (XRD). The evolution of strain induced both in the QDs and cap layers during capping is discussed based on the XRD intensity transients obtained at various lattice constants. Transients with different features are observed from those obtained during InGaAs and GaAs capping. The difference observed is attributed to In-Ga intermixing between the QDs and the cap layer under limited supply of In. Photoluminescence (PL) wavelength can be tuned by controlling the intermixing, which affects both the strain induced in the QDs and the barrier heights. The PL wavelength also varies with the cap layer thickness. A large redshift occurs by reducing the cap thickness. The in situ XRD observation reveals that this is a result of reduced strain. We demonstrate how such information about strain can be applied for designing and preparing novel device structures.

  7. The potential for extending the spectral range accessible to the european X-ray free electron laser in the direction of longer wavelengths

    CERN Document Server

    Saldin, E L; Yurkov, M V

    2004-01-01

    The baseline specifications of European XFEL give a range of wavelengths between 0.1 nm and 2 nm. This wavelength range at fixed electron beam energy 17.5 GeV can be covered by operating the SASE FEL with three undulators which have different period and tunable gap. A study of the potential for the extending the spectral range accessible to the XFEL in the direction of longer wavelengths is presented. The extension of the wavelength range to 6 nm would be cover the water window in the VUV region, opening the facility to a new class of experiments. There are at least two possible sources of VUV radiation associated with the X-ray FEL; the "low (2.5 GeV) energy electron beam dedicated" and the " 17.5 GeV spent beam parasitic" (or "after-burner") source modes. The second alternative, "after-burner undulator" is the one we regard as most favorable. It is possible to place an undulator as long as 80 meters after 2 nm undulator. Ultimately, VUV undulator would be able to deliver output power approaching 100 GW. A b...

  8. Coded Aperture Imaging for Fluorescent X-rays-Biomedical Applications

    Energy Technology Data Exchange (ETDEWEB)

    Haboub, Abdel; MacDowell, Alastair; Marchesini, Stefano; Parkinson, Dilworth

    2013-06-01

    Employing a coded aperture pattern in front of a charge couple device pixilated detector (CCD) allows for imaging of fluorescent x-rays (6-25KeV) being emitted from samples irradiated with x-rays. Coded apertures encode the angular direction of x-rays and allow for a large Numerical Aperture x- ray imaging system. The algorithm to develop the self-supported coded aperture pattern of the Non Two Holes Touching (NTHT) pattern was developed. The algorithms to reconstruct the x-ray image from the encoded pattern recorded were developed by means of modeling and confirmed by experiments. Samples were irradiated by monochromatic synchrotron x-ray radiation, and fluorescent x-rays from several different test metal samples were imaged through the newly developed coded aperture imaging system. By choice of the exciting energy the different metals were speciated.

  9. X-ray polarimetry on-board HXMT

    CERN Document Server

    Soffitta, Paolo; Tagliaferri, Gianpiero; Costa, Enrico; Pareschi, Giovanni; Basso, Stefano; Cotroneo, Vincenzo; Frutti, Massimo; Lazzarotto, Francesco; Muleri, Fabio; Rubini, Alda; Spandre, Gloria; Brez, Alessandro; Baldini, Luca; Bregeon, Jean; Minuti, Massimo; Matt, Giorgio; Frontera, Filippo

    2008-01-01

    The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fraction of the HXMT time will be spent on dedicated pointing of particular sources, it could host, with moderate additional resources a pair of X-ray telescopes, each with a photoelectric X-ray polarimeter (EXP2, Efficient X-ray Photoelectric Polarimeter) in the focal plane. We present the design of the telescopes and the focal plane instrumentation and discuss the performance of this instrument to detect the degree and angle of linear polarization of some representative sources. Notwithstanding the limited resources, the proposed instrument can represent a breakthrough in X-ray Polarimetry.

  10. X-ray Chirped Pulse Amplification: towards GW Soft X-ray Lasers

    Directory of Open Access Journals (Sweden)

    Marta Fajardo

    2013-07-01

    Full Text Available Extensive modeling of the seeding of plasma-based soft X-ray lasers is reported in this article. Seminal experiments on amplification in plasmas created from solids have been studied in detail and explained. Using a transient collisional excitation scheme, we show that a 18 µJ, 80 fs fully coherent pulse is achievable by using plasmas pumped by a compact 10 Hz laser. We demonstrate that direct seeding of plasmas created by nanosecond lasers is not efficient. Therefore, we propose and fully study the transposition to soft X-rays of the Chirped Pulse Amplification (CPA technique. Soft X-ray pulses with energy of 6 mJ and 200 fs duration are reachable by seeding plasmas pumped by compact 100 J, sub-ns, 1 shot/min lasers. These soft X-ray lasers would reach GW power, corresponding to an increase of 100 times as compared to the highest peak power achievable nowadays in the soft X-ray region (30 eV–1 keV. X-ray CPA is opening new horizon for soft x-ray ultra-intense sources.

  11. Imaging in Hard X-ray Astronomy

    CERN Document Server

    Li Ti Pei

    2002-01-01

    The energy range of hard X-rays is a key waveband to the study of high energy processes in celestial objects, but still remains poorly explored. In contrast to direct imaging methods used in the low energy X-ray and high energy gamma-ray bands, currently imaging in the hard X-ray band is mainly achieved through various modulation techniques. A new inversion technique, the direct demodulation method, has been developed since early 90s. With this technique, wide field and high resolution images can be derived from scanning data of a simple collimated detector. The feasibility of this technique has been confirmed by experiment, balloon-borne observation and analyzing simulated and real astronomical data. Based the development of methodology and instrumentation, a high energy astrophysics mission -- Hard X-ray Modulation Telescope (HXMT) has been proposed and selected in China for a four-year Phase-A study. The main scientific objectives are a full-sky hard X-ray (20-200 keV) imaging survey and high signal-to-noi...

  12. Visualization of x-ray computer tomography using computer-generated holography

    Science.gov (United States)

    Daibo, Masahiro; Tayama, Norio

    1998-09-01

    The theory converted from x-ray projection data to the hologram directly by combining the computer tomography (CT) with the computer generated hologram (CGH), is proposed. The purpose of this study is to offer the theory for realizing the all- electronic and high-speed seeing through 3D visualization system, which is for the application to medical diagnosis and non- destructive testing. First, the CT is expressed using the pseudo- inverse matrix which is obtained by the singular value decomposition. CGH is expressed in the matrix style. Next, `projection to hologram conversion' (PTHC) matrix is calculated by the multiplication of phase matrix of CGH with pseudo-inverse matrix of the CT. Finally, the projection vector is converted to the hologram vector directly, by multiplication of the PTHC matrix with the projection vector. Incorporating holographic analog computation into CT reconstruction, it becomes possible that the calculation amount is drastically reduced. We demonstrate the CT cross section which is reconstituted by He-Ne laser in the 3D space from the real x-ray projection data acquired by x-ray television equipment, using our direct conversion technique.

  13. Topological X-Rays Revisited

    Science.gov (United States)

    Lynch, Mark

    2012-01-01

    We continue our study of topological X-rays begun in Lynch ["Topological X-rays and MRI's," iJMEST 33(3) (2002), pp. 389-392]. We modify our definition of a topological magnetic resonance imaging and give an affirmative answer to the question posed there: Can we identify a closed set in a box by defining X-rays to probe the interior and without…

  14. X-ray instrumentation for SR beamlines

    CERN Document Server

    Kovalchuk, M V; Zheludeva, S I; Aleshko-Ozhevsky, O P; Arutynyan, E H; Kheiker, D M; Kreines, A Y; Lider, V V; Pashaev, E M; Shilina, N Y; Shishkov, V A

    2000-01-01

    The main possibilities and parameters of experimental X-ray stations are presented: 'Protein crystallography', 'X-ray structure analysis', 'High-precision X-ray optics', 'X-ray crystallography and material science', 'X-ray topography', 'Photoelectron X-ray standing wave' that are being installed at Kurchatov SR source by A.V. Shubnikov Institute of Crystallography.

  15. Soft X-ray optics

    CERN Document Server

    Spiller, Eberhard A

    1993-01-01

    This text describes optics mainly in the 10 to 500 angstrom wavelength region. These wavelengths are 50 to 100 times shorter than those for visible light and 50 to 100 times longer than the wavelengths of medical x rays or x-ray diffraction from natural crystals. There have been substantial advances during the last 20 years, which one can see as an extension of optical technology to shorter wavelengths or as an extension of x-ray diffraction to longer wavelengths. Artificial diffracting structures like zone plates and multilayer mirrors are replacing the natural crystals of x-ray diffraction.

  16. X-ray Absorption Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Yano, Junko; Yachandra, Vittal K.

    2009-07-09

    This review gives a brief description of the theory and application of X-ray absorption spectroscopy, both X-ray absorption near edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), especially, pertaining to photosynthesis. The advantages and limitations of the methods are discussed. Recent advances in extended EXAFS and polarized EXAFS using oriented membranes and single crystals are explained. Developments in theory in understanding the XANES spectra are described. The application of X-ray absorption spectroscopy to the study of the Mn4Ca cluster in Photosystem II is presented.

  17. In-plane X-ray diffraction study of the C-60/Au(110) p(6x5) reconstructed surface by direct methods

    NARCIS (Netherlands)

    Torrelles, X.; Rius, J.; Pedio, M.; Felici, R.; Rudolf, P.; Ferrer, S.; Miravitlles, C.; Alvarez, J.

    1999-01-01

    Adsorption of C60 on the highly anisotropic Au(110) 1 × 2 reconstructed surface leads to an ordered quasi hexagonal 6 × 5 superstructure. This interfacial reconstruction has been investigated by grazing incidence X-ray diffraction. Analysis of the in-plane data set reveals four C60 molecules per (6

  18. Direct monitoring of calcium-triggered phase transitions in cubosomes using small-angle X-ray scattering combined with microfluidics

    DEFF Research Database (Denmark)

    Ghazal, Aghiad; Gontsarik, Mark; Kutter, Jörg P.

    2016-01-01

    This article introduces a simple microfluidic device that can be combined with synchrotron small-angle X-ray scattering (SAXS) for monitoring dynamic structural transitions. The microfluidic device is a thiol-ene-based system equipped with 125 µm-thick polystyrene windows, which are suitable for ...

  19. In-plane X-ray diffraction study of the C-60/Au(110) p(6x5) reconstructed surface by direct methods

    NARCIS (Netherlands)

    Torrelles, X.; Rius, J.; Pedio, M.; Felici, R.; Rudolf, P.; Ferrer, S.; Miravitlles, C.; Alvarez, J.

    1999-01-01

    Adsorption of C60 on the highly anisotropic Au(110) 1 × 2 reconstructed surface leads to an ordered quasi hexagonal 6 × 5 superstructure. This interfacial reconstruction has been investigated by grazing incidence X-ray diffraction. Analysis of the in-plane data set reveals four C60 molecules per (6

  20. Direct observation of strain in bulk subgrains and dislocation walls by high angular resolution three-dimensional X-ray diffraction

    DEFF Research Database (Denmark)

    Jakobsen, Bo; Lienert, U.; Almer, J.;

    2008-01-01

    The X-ray diffraction (XRD) method "high angular resolution 3DXRD" is briefly introduced, and results are presented for a single bulk grain in a polycrystalline copper sample deformed in tension. It is found that the three-dimensional reciprocal-space intensity distribution of a 400 reflection...

  1. Nordic working group on x-ray diagnostics - Practical implementation of the directive on medical exposures in the Nordic EU countries

    Energy Technology Data Exchange (ETDEWEB)

    Waltenburg, H.N.; Groen, P. [National Institute of Radiation Hygiene, Herlev (Denmark); Leitz, W. [Swedish Radiation Protection Authority, Stockholm (Sweden); Servomaa, A. [Finnish Centre for Radiation and Nuclear Safety, Helsinki (Finland); Einarsson, G. [Icelandic Radiation Protection Institute, Reykjavik (Iceland); Olerud, H. [Norwegian Radiation Protection Authority, Oslo (Norway)

    2003-06-01

    . We will not cover all aspects of MED, instead we have chosen specific points that we think are the most interesting. The scope is limited to diagnostic applications of x-rays, excluding dental, therapy and nuclear medicine applications. (orig.)

  2. X-Ray Wakes in Abell 160

    CERN Document Server

    Drake, N; Sakelliou, I; Pinkney, J C; Drake, Nick; Merrifield, Michael R.; Sakelliou, Irini; Pinkney, Jason C.

    2000-01-01

    `Wakes' of X-ray emission have now been detected trailing behind a few (at least seven) elliptical galaxies in clusters. To quantify how widespread this phenomenon is, and what its nature might be, we have obtained a deep (70 ksec) X-ray image of the poor cluster Abell 160 using the ROSAT HRI. Combining the X-ray data with optical positions of confirmed cluster members, and applying a statistic designed to search for wake-like excesses, we confirm that this phenomenon is observed in galaxies in this cluster. The probability that the detections arise from chance is less than 0.0038. Further, the wakes are not randomly distributed in direction, but are preferentially oriented pointing away from the cluster centre. This arrangement can be explained by a simple model in which wakes arise from the stripping of their host galaxies' interstellar media due to ram pressure against the intracluster medium through which they travel.

  3. Laboratory Data for X-Ray Astronomy

    Energy Technology Data Exchange (ETDEWEB)

    Beiersdorfer, P.; Brown, G.V.; Chen, H.; Gu, M.F.; Kahn, S.M.; Lepson, J.K.; Savin, D.W.; Utter, S.B.

    2000-03-02

    Laboratory facilities have made great strides in producing large sets of reliable data for X-ray astronomy, which include ionization and recombination cross sections needed for charge balance calculations as well as the atomic data needed for interpreting X-ray line formation. We discuss data from the new generation sources and pay special attention to the LLNL electron beam ion trap experiment, which is unique in it's ability to provide direct laboratory access to spectral data under precisely controlled conditions that simulate those found in many astrophysical plasmas. Examples of spectral data obtained in the 1-160 A wavelength range are given illustrating the type of laboratory X-ray data produced in support of such missions as Chandra, XMM, ASCA and EUVE.

  4. X-Ray Attenuation Cell

    Energy Technology Data Exchange (ETDEWEB)

    Ryutov, D.; Toor, A.

    2000-03-03

    To minimize the pulse-to-pulse variation, the LCLS FEL must operate at saturation, i.e. 10 orders of magnitude brighter spectral brilliance than 3rd-generation light sources. At this intensity, ultra-high vacuums and windowless transport are required. Many of the experiments, however, will need to be conducted at a much lower intensity thereby requiring a reliable means to reduce the x-ray intensity by many orders of magnitude without increasing the pulse-to-pulse variation. In this report we consider a possible solution for controlled attenuation of the LCLS x-ray radiation. We suggest using for this purpose a windowless gas-filled cell with the differential pumping. Although this scheme is easily realizable in principle, it has to be demonstrated that the attenuator can be made short enough to be practical and that the gas loads delivered to the vacuum line of sight (LOS) are acceptable. We are not going to present a final, optimized design. Instead, we will provide a preliminary analysis showing that the whole concept is robust and is worth further study. The spatial structure of the LCLS x-ray pulse at the location of the attenuator is shown in Fig. 1. The central high-intensity component, due to the FEL, has a FWHM of {approx}100 {micro}m. A second component, due to the undulator's broad band spontaneous radiation is seen as a much lower intensity ''halo'' with a FWHM of 1 mm. We discuss two versions of the attenuation cell. The first is directed towards a controlled attenuation of the FEL up to the 4 orders of magnitude in the intensity, with the spontaneous radiation halo being eliminated by collimators. In the second version, the spontaneous radiation is not sacrificed but the FEL component (as well as the first harmonic of the spontaneous radiation) gets attenuated by a more modest factor up to 100. We will make all the estimates assuming that the gas used in the attenuator is Xenon and that the energy of the FEL is 8.25 keV. At

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... bone absorbs much of the radiation while soft tissue, such as muscle, fat and organs, allow more of the x-rays to pass through them. As a result, bones appear white on the x-ray, soft tissue shows up in shades of gray and air ...

  7. Development of a new X-ray source using backscattered X-ray with the use of a cold cathode

    Science.gov (United States)

    Tanizawa, Keisuke; Sekiya, Tetsuo; Ohshio, Shigeo; Akasaka, Hiroki; Saitoh, Hidetoshi

    2011-02-01

    The development of an intense X-ray source using backscattered X-ray produced using an advanced electrode configuration is described. The electrodes were composed of field emitters deposited on a wire mounted on a perforated plate as the cathode and a copper plate as the anode. Electrons from these emitters collided with the copper plate and X-ray was generated at collision points. The backscattered X-ray in the direction normal to the electron trajectory through a hole in the anode escaped from the vacuum chamber through a beryllium window. Continuous and characteristic X-rays were detected at an applied voltage lower than that of a conventional X-ray source from 3.0 to 9.4 kV, respectively. Moreover, the X-ray dosage measured with a survey meter reached 0.95 mSv/h at 5.0 kV of applied voltage. The transmission images of three types of material used as an X-ray source for the X-ray imaging system indicate three advantages; low power consumption, focal point controllable by adjusting applied voltage, and photographable motion picture of X-ray transmission.

  8. Focusing X-Ray Telescopes

    Science.gov (United States)

    O'Dell, Stephen; Brissenden, Roger; Davis, William; Elsner, Ronald; Elvis, Martin; Freeman, Mark; Gaetz, Terrance; Gorenstein, Paul; Gubarev, Mikhall; Jerlus, Diab; Juda, Michael; Kolodziejczak, Jeffrey; Murray, Stephen; Petre, Robert; Podgorski, William; Ramsey, Brian; Reid, Paul; Saha, Timo; Wolk, Scott; Troller-McKinstry, Susan; Weisskopf, Martin; Wilke, Rudeger; Zhang, William

    2010-01-01

    During the half-century history of x-ray astronomy, focusing x-ray telescopes, through increased effective area and finer angular resolution, have improved sensitivity by 8 orders of magnitude. Here, we review previous and current x-ray-telescope missions. Next, we describe the planned next-generation x-ray-astronomy facility, the International X-ray Observatory (IXO). We conclude with an overview of a concept for the next next-generation facility, Generation X. Its scientific objectives will require very large areas (about 10,000 sq m) of highly-nested, lightweight grazing-incidence mirrors, with exceptional (about 0.1-arcsec) resolution. Achieving this angular resolution with lightweight mirrors will likely require on-orbit adjustment of alignment and figure.

  9. X-Ray Tomographic Reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Bonnie Schmittberger

    2010-08-25

    Tomographic scans have revolutionized imaging techniques used in medical and biological research by resolving individual sample slices instead of several superimposed images that are obtained from regular x-ray scans. X-Ray fluorescence computed tomography, a more specific tomography technique, bombards the sample with synchrotron x-rays and detects the fluorescent photons emitted from the sample. However, since x-rays are attenuated as they pass through the sample, tomographic scans often produce images with erroneous low densities in areas where the x-rays have already passed through most of the sample. To correct for this and correctly reconstruct the data in order to obtain the most accurate images, a program employing iterative methods based on the inverse Radon transform was written. Applying this reconstruction method to a tomographic image recovered some of the lost densities, providing a more accurate image from which element concentrations and internal structure can be determined.

  10. X-Ray Diffraction Apparatus

    Science.gov (United States)

    Blake, David F. (Inventor); Bryson, Charles (Inventor); Freund, Friedmann (Inventor)

    1996-01-01

    An x-ray diffraction apparatus for use in analyzing the x-ray diffraction pattern of a sample is introduced. The apparatus includes a beam source for generating a collimated x-ray beam having one or more discrete x-ray energies, a holder for holding the sample to be analyzed in the path of the beam, and a charge-coupled device having an array of pixels for detecting, in one or more selected photon energy ranges, x-ray diffraction photons produced by irradiating such a sample with said beam. The CCD is coupled to an output unit which receives input information relating to the energies of photons striking each pixel in the CCD, and constructs the diffraction pattern of photons within a selected energy range striking the CCD.

  11. The fast wavelet X-ray transform

    NARCIS (Netherlands)

    R.A. Zuidwijk; P.M. de Zeeuw (Paul)

    1999-01-01

    textabstractThe wavelet X-ray transform computes one-dimensional wavelet transforms along lines in Euclidian space in order to perform a directional time-scale analysis of functions in several variables. A fast algorithm is proposed which executes this transformation starting with values given on a

  12. CMOS APS detector characterization for quantitative X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Endrizzi, Marco, E-mail: m.endrizzi@ucl.ac.uk [Dipartimento di Fisica, Università di Siena, Via Roma 56, 53100 Siena (Italy); Istituto Nazionale di Fisica Nucleare INFN, sezione di Pisa, 56127 Pisa (Italy); Oliva, Piernicola [Dipartimento di Chimica e Farmacia, Università di Sassari, via Piandanna 4, 07100 Sassari (Italy); Istituto Nazionale di Fisica Nucleare INFN, Sezione di Cagliari, 09042 Cagliari (Italy); Golosio, Bruno [Sezione di Matematica, Fisica e Ingegneria dell' Informazione, Università di Sassari, via Piandanna 4, 07100 Sassari (Italy); Istituto Nazionale di Fisica Nucleare INFN, Sezione di Cagliari, 09042 Cagliari (Italy); Delogu, Pasquale [Dipartimento di Fisica “E. Fermi”, Università di Pisa, Largo B. Pontecorvo 3, 56127 Pisa (Italy); Istituto Nazionale di Fisica Nucleare INFN, sezione di Pisa, 56127 Pisa (Italy)

    2013-03-01

    An X-ray Imaging detector based on CMOS Active Pixel Sensor and structured scintillator is characterized for quantitative X-ray imaging in the energy range 11–30 keV. Linearity, dark noise, spatial resolution and flat-field correction are the characteristics of the detector subject of investigation. The detector response, in terms of mean Analog-to-Digital Unit and noise, is modeled as a function of the energy and intensity of the X-rays. The model is directly tested using monochromatic X-ray beams and it is also indirectly validated by means of polychromatic X-ray-tube spectra. Such a characterization is suitable for quantitative X-ray imaging and the model can be used in simulation studies that take into account the actual performance of the detector.

  13. Transient and Capillary Collisional X-ray Laser

    Energy Technology Data Exchange (ETDEWEB)

    Shlyaptsev, V N; Dunn, J; Fournier, K B; Moon, S; Osterheld, A L; Rocca, J J; Detering, F; Rozmus, W; Matte, J P; Fiedorowicz, H; Bartnik, A; Kanouff, M

    2001-12-17

    In this work we report our numerical modeling results of laser-generated transient inversion and capillary discharge X-ray lasers. In the search for more efficient X-ray lasers we look closely at other approaches in conjunction with experiments at LLNL. In the search for improved X-ray lasers we perform modeling and experimental investigations of low density targets including gas puff targets. We have found the importance of plasma kinetics in transient X-ray lasers by expanding the physical model beyond hydrodynamics approach with Particle In Cell (PIC) and Fokker-Planck codes. The evidence of the Langdon effect was inferred from the recent experimental data obtained with the Ni-like Pd X-ray laser. We continue modeling different kinds of capillary discharge plasma configurations directed toward shorter wavelength X-ray lasers, plasma diagnostics and other applications.

  14. X-ray monitoring optical elements

    Energy Technology Data Exchange (ETDEWEB)

    Stoupin, Stanislav; Shvydko, Yury; Katsoudas, John; Blank, Vladimir D.; Terentyev, Sergey A.

    2016-12-27

    An X-ray article and method for analyzing hard X-rays which have interacted with a test system. The X-ray article is operative to diffract or otherwise process X-rays from an input X-ray beam which have interacted with the test system and at the same time provide an electrical circuit adapted to collect photoelectrons emitted from an X-ray optical element of the X-ray article to analyze features of the test system.

  15. X-ray diagnostics for TFTR

    Energy Technology Data Exchange (ETDEWEB)

    von Goeler, S.; Hill, K.W.; Bitter, M.

    1982-12-01

    A short description of the x-ray diagnostic preparation for the TFTR tokamak is given. The x-ray equipment consists of the limiter x-ray monitoring system, the soft x-ray pulse-height-analysis-system, the soft x-ray imaging system and the x-ray crystal spectrometer. Particular attention is given to the radiation protection of the x-ray systems from the neutron environment.

  16. X-RAY POLARIZATION FROM HIGH-MASS X-RAY BINARIES

    Energy Technology Data Exchange (ETDEWEB)

    Kallman, T. [NASA/GSFC, Code 662, Greenbelt, MD 20771 (United States); Dorodnitsyn, A. [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States); Blondin, J. [Department of Physics, North Carolina State University, Raleigh, NC 27695-8202 (United States)

    2015-12-10

    X-ray astronomy allows study of objects that may be associated with compact objects, i.e., neutron stars or black holes, and also may contain strong magnetic fields. Such objects are categorically nonspherical, and likely noncircular when projected on the sky. Polarization allows study of such geometric effects, and X-ray polarimetry is likely to become feasible for a significant number of sources in the future. Potential targets for future X-ray polarization observations are the high-mass X-ray binaries (HMXBs), which consist of a compact object in orbit with an early-type star. In this paper we show that X-ray polarization from HMXBs has a distinct signature that depends on the source inclination and orbital phase. The presence of the X-ray source displaced from the star creates linear polarization even if the primary wind is spherically symmetric whenever the system is viewed away from conjunction. Direct X-rays dilute this polarization whenever the X-ray source is not eclipsed; at mid-eclipse the net polarization is expected to be small or zero if the wind is circularly symmetric around the line of centers. Resonance line scattering increases the scattering fraction, often by large factors, over the energy band spanned by resonance lines. Real winds are not expected to be spherically symmetric, or circularly symmetric around the line of centers, owing to the combined effects of the compact object gravity and ionization on the wind hydrodynamics. A sample calculation shows that this creates polarization fractions ranging up to tens of percent at mid-eclipse.

  17. Development of X-ray CCD camera based X-ray micro-CT system.

    Science.gov (United States)

    Sarkar, Partha S; Ray, N K; Pal, Manoj K; Baribaddala, Ravi; Agrawal, Ashish; Kashyap, Y; Sinha, A; Gadkari, S C

    2017-02-01

    Availability of microfocus X-ray sources and high resolution X-ray area detectors has made it possible for high resolution microtomography studies to be performed outside the purview of synchrotron. In this paper, we present the work towards the use of an external shutter on a high resolution microtomography system using X-ray CCD camera as a detector. During micro computed tomography experiments, the X-ray source is continuously ON and owing to the readout mechanism of the CCD detector electronics, the detector registers photons reaching it during the read-out period too. This introduces a shadow like pattern in the image known as smear whose direction is defined by the vertical shift register. To resolve this issue, the developed system has been incorporated with a synchronized shutter just in front of the X-ray source. This is positioned in the X-ray beam path during the image readout period and out of the beam path during the image acquisition period. This technique has resulted in improved data quality and hence the same is reflected in the reconstructed images.

  18. Magnetar-like X-ray bursts from an anomalous X-ray pulsar.

    Science.gov (United States)

    Gavriil, F P; Kaspi, V M; Woods, P M

    2002-09-12

    Anomalous X-ray pulsars (AXPs) are a class of rare X-ray emitting pulsars whose energy source has been perplexing for some 20 years. Unlike other X-ray emitting pulsars, AXPs cannot be powered by rotational energy or by accretion of matter from a binary companion star, hence the designation 'anomalous'. Many of the rotational and radiative properties of the AXPs are strikingly similar to those of another class of exotic objects, the soft-gamma-ray repeaters (SGRs). But the defining property of the SGRs--their low-energy-gamma-ray and X-ray bursts--has not hitherto been observed for AXPs. Soft-gamma-ray repeaters are thought to be 'magnetars', which are young neutron stars whose emission is powered by the decay of an ultra-high magnetic field; the suggestion that AXPs might also be magnetars has been controversial. Here we report two X-ray bursts, with properties similar to those of SGRs, from the direction of the anomalous X-ray pulsar 1E1048.1 - 5937. These events imply a close relationship (perhaps evolutionary) between AXPs and SGRs, with both being magnetars.

  19. Development of X-ray CCD camera based X-ray micro-CT system

    Science.gov (United States)

    Sarkar, Partha S.; Ray, N. K.; Pal, Manoj K.; Baribaddala, Ravi; Agrawal, Ashish; Kashyap, Y.; Sinha, A.; Gadkari, S. C.

    2017-02-01

    Availability of microfocus X-ray sources and high resolution X-ray area detectors has made it possible for high resolution microtomography studies to be performed outside the purview of synchrotron. In this paper, we present the work towards the use of an external shutter on a high resolution microtomography system using X-ray CCD camera as a detector. During micro computed tomography experiments, the X-ray source is continuously ON and owing to the readout mechanism of the CCD detector electronics, the detector registers photons reaching it during the read-out period too. This introduces a shadow like pattern in the image known as smear whose direction is defined by the vertical shift register. To resolve this issue, the developed system has been incorporated with a synchronized shutter just in front of the X-ray source. This is positioned in the X-ray beam path during the image readout period and out of the beam path during the image acquisition period. This technique has resulted in improved data quality and hence the same is reflected in the reconstructed images.

  20. Semiconductor X-ray detectors

    CERN Document Server

    Lowe, Barrie Glyn

    2014-01-01

    Identifying and measuring the elemental x-rays released when materials are examined with particles (electrons, protons, alpha particles, etc.) or photons (x-rays and gamma rays) is still considered to be the primary analytical technique for routine and non-destructive materials analysis. The Lithium Drifted Silicon (Si(Li)) X-Ray Detector, with its good resolution and peak to background, pioneered this type of analysis on electron microscopes, x-ray fluorescence instruments, and radioactive source- and accelerator-based excitation systems. Although rapid progress in Silicon Drift Detectors (SDDs), Charge Coupled Devices (CCDs), and Compound Semiconductor Detectors, including renewed interest in alternative materials such as CdZnTe and diamond, has made the Si(Li) X-Ray Detector nearly obsolete, the device serves as a useful benchmark and still is used in special instances where its large, sensitive depth is essential. Semiconductor X-Ray Detectors focuses on the history and development of Si(Li) X-Ray Detect...

  1. Sample holder for X-ray diffractometry

    Science.gov (United States)

    Hesch, Victor L.

    1992-01-01

    A sample holder for use with X-ray diffractometers with the capability to rotate the sample, as well as to adjust the position of the sample in the x, y, and z directions. Adjustment in the x direction is accomplished through loosening set screws, moving a platform, and retightening the set screws. Motion translators are used for adjustment in the y and z directions. An electric motor rotates the sample, and receives power from the diffractometer.

  2. Impulsive solar X-ray bursts. 3: Polarization and directivity of bremsstrahlung radiation from a beam of electrons directed toward the photosphere

    Science.gov (United States)

    Langer, S. H.; Petrosian, V.

    1976-01-01

    The spectrum, directivity and state of polarization is presented of the bremsstrahlung radiation expected from a beam of high energy electrons spiraling along radial magnetic field lines toward the photosphere. The results are used for calculation of the characteristics of the reflected plus direct flux.

  3. A Solution to Hammer's X-ray Reconstruction Problem

    DEFF Research Database (Denmark)

    Gardner, Richard J.; Kiderlen, Markus

    2007-01-01

    We propose algorithms for reconstructing a planar convex body K from possibly noisy measurements of either its parallel X-rays taken in a fixed finite set of directions or its point X-rays taken at a fixed finite set of points, in known situations that guarantee a unique solution when the data is...

  4. The NuSTAR Extragalactic Survey: First Direct Measurements of the Greater Than Or Similar To 10 Kev X-Ray Luminosity Function For Active Galactic Nuclei At z > 0.1

    DEFF Research Database (Denmark)

    Aird, J.; Alexander, D. M.; Ballantyne, D. R.;

    2015-01-01

    number of sources in our sample, leading to small, systematic differences in our binned estimates of the XLF. Adopting a model with a lower intrinsic fraction of Compton-thick sources and a larger population of sources with column densities NH ∼1023-24 cm-2 or a model with stronger Compton reflection......We present the first direct measurements of the rest-frame 10-40 keV X-ray luminosity function (XLF) of active galactic nuclei (AGNs) based on a sample of 94 sources at 0.1 sources in the Nuclear Spectroscopic Telescope Array (NuSTAR) extragalactic survey...... component (with a relative normalization of R ∼ 2 at all luminosities) can bring extrapolations of the XLF from 2-10 keV into agreement with our NuSTAR sample. Ultimately, X-ray spectral analysis of the NuSTAR sources is required to break this degeneracy between the distribution of absorbing column...

  5. The expert knowledge as defined by the X-ray Ordinance. Directive on competence and expert knowledge in radiation protection, required for the personnel applying X-ray equipment in medicine, dentistry, and veterinary medicine, as defined by the X-ray Ordinance/medicine. Fachkunde nach Roentgenverordnung. Richtlinie Fachkunde und Kenntnisse im Strahlenschutz fuer den Betrieb von Roentgeneinrichtungen in der Medizin, Zahnmedizin und bei der Anwendung von Roentgenstrahlen auf Tiere - Fachkunde nach Roentgenverordnung/Medizin

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-01

    Persons applying within their role responsibility X-rays in medicine or veterinary medicine, or persons with a responsibility as radiation protection officer or according to section 24, sub-sec. (3) Radiation Protection Ordinance have to give proof of the required expert knowledge (section 3, sub-sec. (2), no. 3, section 4, sub-sec. (1) no. 3, section 13, sub-sec. (4), section 23 no.s. 1 and 3 of the X-ray Ordinance). In addition, persons applying X-rays under the supervision and responsibility of a medical specialist or dentist, have to acquire the knowledge in radiation protection as defined by section 23, no. 2 and 4 X-ray Ordinance. As to the application of X-rays in veterinary medicine, the expert knowledge required is defined in section 3, sub-sec. (2) no. 3, section 4, sub-sec. 1 no. 3, section 13, sub-sec. (4), section 29 sub-sec. (1) no. 4 of the X-ray Ordinance. The knowledge to be acquired in radiation protection is given in section 29, sub-sec. (1) no. 3 of the X-ray Ordinance. The radiation protection officer or persons responsible for radiation protection have to give proof of their expert knowledge within the course of the licensing or notification procedure in accordance with sections 3 and 4 of the X-ray Ordinance, or in the course of the procedure for appointment of a radiation protection officier in accordance with section 13, sub-sec. (3) of the X-ray Ordinance. (orig.).

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... during x-ray examinations to use the lowest radiation dose possible while producing the best images for evaluation. National and international radiology protection organizations continually review ...

  7. Bone X-Ray (Radiography)

    Science.gov (United States)

    ... bony fragments following treatment of a fracture. guide orthopedic surgery, such as spine repair/fusion, joint replacement ... A portable x-ray machine is a compact apparatus that can be taken to the patient in ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the oldest and most frequently used form of medical imaging. A bone x-ray makes images of any ... a radiologist or other physician. To locate a medical imaging or radiation oncology provider in your community, you ...

  9. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... replacement and fracture reductions. look for injury, infection, arthritis , abnormal bone growths and bony changes seen in ... injuries, including fractures, and joint abnormalities, such as arthritis. X-ray equipment is relatively inexpensive and widely ...

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... top of page What are the benefits vs. risks? Benefits Bone x-rays are the fastest and ... in the typical diagnostic range for this exam. Risks There is always a slight chance of cancer ...

  11. CELESTIAL X-RAY SOURCES.

    Science.gov (United States)

    sources, (4) the physical conditions in the pulsating x-ray source in the Crab Nebula , and (5) miscellaneous related topics. A bibliography of all work performed under the contract is given. (Author)

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... asked to wait until the radiologist determines that all the necessary images have been obtained. A bone ... while it may be barely seen, if at all, on a hip x-ray. For suspected spine ...

  13. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patients and physicians. Because x-ray imaging is fast and easy, it is particularly useful in emergency ... diagnosis and treatment of the individual patient's condition. Ultrasound imaging, which uses sound waves instead of ionizing ...

  14. X-Ray Assembler Data

    Data.gov (United States)

    U.S. Department of Health & Human Services — Federal regulations require that an assembler who installs one or more certified components of a diagnostic x-ray system submit a report of assembly. This database...

  15. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... a form of radiation like light or radio waves. X-rays pass through most objects, including the ... individual patient's condition. Ultrasound imaging, which uses sound waves instead of ionizing radiation to create diagnostic images, ...

  16. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... pregnant. Many imaging tests are not performed during pregnancy so as not to expose the fetus to ... See the Safety page for more information about pregnancy and x-rays. top of page What does ...

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... are easily accessible and are frequently compared to current x-ray images for diagnosis and disease management. ... of North America, Inc. (RSNA). To help ensure current and accurate information, we do not permit copying ...

  18. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... ionizing radiation to produce pictures of any bone in the body. It is commonly used to diagnose ... bone x-ray makes images of any bone in the body, including the hand, wrist, arm, elbow, ...

  19. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... examination may also be necessary so that any change in a known abnormality can be monitored over ...

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... patients and physicians. Because x-ray imaging is fast and easy, it is particularly useful in emergency ... 06, 2016 Send us your feedback Did you find the information you were looking for? Yes No ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... in emergency rooms, physician offices, ambulatory care centers, nursing homes and other locations, making it convenient for ... Safety page for more information about radiation dose. Women should always inform their physician or x-ray ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... evaluation with additional views or a special imaging technique. A follow-up examination may also be necessary ... radiology protection organizations continually review and update the technique standards used by radiology professionals. Modern x-ray ...

  3. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray images were maintained on large film sheets (much like a large photographic negative). Today, most ... accredited facilities database . This website does not provide cost information. The costs for specific medical imaging tests, ...

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... x-ray machine is a compact apparatus that can be taken to the patient in a hospital ... so that any change in a known abnormality can be monitored over time. Follow-up examinations are ...

  5. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... in a known abnormality can be monitored over time. Follow-up examinations are sometimes the best way ...

  6. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... code: Phone no: Thank you! Do you have a personal story about radiology? Share your patient story ...

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... current x-ray images for diagnosis and disease management. top of page How is the procedure performed? ... these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological ...

  8. Electromechanical x-ray generator

    Energy Technology Data Exchange (ETDEWEB)

    Watson, Scott A; Platts, David; Sorensen, Eric B

    2016-05-03

    An electro-mechanical x-ray generator configured to obtain high-energy operation with favorable energy-weight scaling. The electro-mechanical x-ray generator may include a pair of capacitor plates. The capacitor plates may be charged to a predefined voltage and may be separated to generate higher voltages on the order of hundreds of kV in the AK gap. The high voltage may be generated in a vacuum tube.

  9. Accelerator x-ray sources

    CERN Document Server

    Talman, Richard

    2007-01-01

    This first book to cover in-depth the generation of x-rays in particle accelerators focuses on electron beams produced by means of the novel Energy Recovery Linac (ERL) technology. The resulting highly brilliant x-rays are at the centre of this monograph, which continues where other books on the market stop. Written primarily for general, high energy and radiation physicists, the systematic treatment adopted by the work makes it equally suitable as an advanced textbook for young researchers.

  10. X-ray fluorescence holography

    CERN Document Server

    Hayashi, K; Takahashi, Y

    2003-01-01

    X-ray fluorescence holography (XFH) is a new structural analysis method of determining a 3D atomic arrangement around fluorescing atoms. We developed an XFH apparatus using advanced X-ray techniques and succeeded in obtaining high-quality hologram data. Furthermore, we introduced applications to the structural analysis of a thin film and the environment around dopants and, discussed the quantitative analysis of local lattice distortion. (author)

  11. X-ray Sensitive Material

    Science.gov (United States)

    2015-12-01

    these published reports. There were two main types of X-ray detection methods: “indirect,” which uses a scintillation material coupled to a light...Reference 3), inorganic semiconductors (silicon [Si], cadmium zinc telluride [CdZnTe]) (Reference 4) and selenium (References 5 and 6), Ne-Xe...metal-oxide semiconductor field-effect transistor (MOSFET) X-ray dosimeters (Reference 24). Electrets may be charged by a range of methods

  12. X-ray voltabsorptometry on redox proteins

    Energy Technology Data Exchange (ETDEWEB)

    Ascone, Isabella [Dipartimento di Fisica, Universita di Roma ' La Sapienza' , P.le A. Moro 5, 00185 Rome (Italy) and LURE/CNRS Centre Universitaire Paris-Sud, bat. 209 D, B.P. 34, 91898 Orsay Cedex (France)]. E-mail: i.ascone@caspur.it; Zamponi, Silvia [Dipartimento di Scienze Chimiche, Universita di Camerino, Via S. Agostino 1, 62032 Camerino (Italy); Cognigni, Andrea [LURE/CNRS Centre Universitaire Paris-Sud, bat. 209 D, B.P. 34, 91898 Orsay Cedex (France); Marmocchi, Franco [Dipartimento di Biologia Molecolare, Cellulare e Animale, Universita di Camerino, Via Camerini, 1 Camerino (Italy); Marassi, Roberto [Dipartimento di Scienze Chimiche, Universita di Camerino, Via S. Agostino 1, 62032 Camerino (Italy)

    2005-04-15

    Biological X-ray absorption spectroscopy (BioXAS) is able to describe the metal environment in a metalloprotein and is sensitive to metal oxidation state. Coupling of BioXAS and electrochemistry permits the characterization of different oxidation states and avoids uncontrolled protein redox state changes due to X-ray beam irradiation. XAS spectroelectrochemistry requires electrochemical cells specifically designed to meet the requirements of both XAS measurements and electrochemical effectiveness in potential control. In this context, this paper describes a new cell tested with different types of working electrodes developed for BioXAS, in particular for in situ studies of redox proteins. The XAS electrochemical measurements of a relatively high-molecular-weight protein (Cu,Zn superoxide dismutase) for which it is difficult to observe direct electrochemistry have been achieved. New working electrodes, capable of fast and unmediated electron transfer, are described. The cell permits to isolate protein redox states and to measure X-ray absorption intensity during a potential scan (X-ray voltabsorptometry)

  13. X-Rays, Pregnancy and You

    Science.gov (United States)

    ... and Procedures Medical Imaging Medical X-ray Imaging X-Rays, Pregnancy and You Share Tweet Linkedin Pin ... the decision with your doctor. What Kind of X-Rays Can Affect the Unborn Child? During most ...

  14. Fast and direct Na and K determination in table, marine, and low-sodium salts by X-ray fluorescence and chemometrics.

    Science.gov (United States)

    Da-Col, José A; Bueno, Maria I M S; Melquiades, Fábio L

    2015-03-11

    X-ray fluorescence (XRF) is a fast, low-cost, nondestructive, and truly multielement analytical technique. The objectives of this study are to quantify the amount of Na(+) and K(+) in samples of table salt (refined, marine, and light) and to compare three different methodologies of quantification using XRF. A fundamental parameter method revealed difficulties in quantifying accurately lighter elements (Z fast. Na(+) quantifications provided calibration errors lower than 16% and a correlation of 0.995. Of great concern was the observation of high Na(+) levels in low-sodium salts. The presented application may be performed in a fast and multielement fashion, in accordance with Green Chemistry specifications.

  15. Direct observation of the critical relaxation of polarization clusters in BaTiO3 using a pulsed x-ray laser technique.

    Science.gov (United States)

    Namikawa, K; Kishimoto, M; Nasu, K; Matsushita, E; Tai, R Z; Sukegawa, K; Yamatani, H; Hasegawa, H; Nishikino, M; Tanaka, M; Nagashima, K

    2009-11-06

    We have developed a new method to investigate the relaxation time of the dipole moment in polarization clusters in BaTiO3. Time correlation of speckle intensities was measured by the use of a double pulsed soft x-ray laser. The evolution of the relaxation time of the dipole moment near the Curie temperature (T(C)) was investigated. The maximum relaxation time (approximately 90 ps) is shown to appear at a temperature of 4.5 K above the T(C), being coincident with the one where the maximum polarization takes place. This method is widely applicable to any other critical decay processes at phase transitions.

  16. X-ray shout echoing through space

    Science.gov (United States)

    2004-01-01

    a flash of X-rays hi-res Size hi-res: 3991 Kb Credits: ESA, S. Vaughan (University of Leicester) EPIC camera shows the expanding rings caused by a flash of X-rays XMM-Newton's X-ray EPIC camera shows the expanding rings caused by a flash of X-rays scattered by dust in our Galaxy. The X-rays were produced by a powerful gamma-ray burst that took place on 3 December 2003. The slowly fading afterglow of the gamma-ray burst is at the centre of the expanding rings. Other, unrelated, X-ray sources can also be seen. The time since the gamma-ray explosion is shown in each panel in hours. At their largest size, the rings would appear in the sky about five times smaller than the full moon. a flash of X-rays hi-res Size hi-res: 2153 Kb Credits: ESA, S. Vaughan (University of Leicester) EPIC camera shows the expanding rings caused by a flash of X-rays (Please choose "hi-res" version for animation) XMM-Newton's X-ray EPIC camera shows the expanding rings caused by a flash of X-rays scattered by dust in our Galaxy. The X-rays were produced by a powerful gamma-ray burst that took place on 3 December 2003. The slowly fading afterglow of the gamma-ray burst is at the centre of the expanding rings. Other, unrelated, X-ray sources can also be seen. The time since the gamma-ray explosion is shown in each panel in seconds. At their largest size, the rings would appear in the sky about five times smaller than the full moon. This echo forms when the powerful radiation of a gamma-ray burst, coming from far away, crosses a slab of dust in our Galaxy and is scattered by it, like the beam of a lighthouse in clouds. Using the expanding rings to precisely pin-point the location of this dust, astronomers can identify places where new stars and planets are likely to form. On 3 December 2003 ESA's observatory, Integral, detected a burst of gamma rays, lasting about 30 seconds, from the direction of a distant galaxy. Within minutes of the detection, thanks to a sophisticated alert network, many

  17. Efficacy of Combined Endoscopic Lithotomy and Extracorporeal Shock Wave Lithotripsy, and Additional Electrohydraulic Lithotripsy Using the SpyGlass Direct Visualization System or X-Ray Guided EHL as Needed, for Pancreatic Lithiasis

    Directory of Open Access Journals (Sweden)

    Ken Ito

    2014-01-01

    Full Text Available Introduction. To evaluate the efficacy of combined endoscopic lithotomy and extracorporeal shock wave lithotripsy (ESWL, and additional electrohydraulic lithotripsy (EHL as needed, for the treatment of pancreatic duct stones, we retrospectively evaluated 98 patients with chronic pancreatitis and pancreatic lithiasis. Methods. For the management of main pancreatic duct (MPD stones in 98 patients, we performed combined endoscopic treatment (ET/ESWL therapy as the first treatment option. When combined ET/ESWL was unsuccessful, EHL with the SpyGlass Direct Visualization system or X-ray guided EHL was performed. Outpatient ESWL was reserved as one of the final treatment options. Results. Fragmentation was successful in 80 (81.6% patients as follows: combined ET/ESWL: 67 cases; SpyGlass EHL: 4 cases; X-ray guided EHL: 3 cases; and outpatient ESWL: 6 cases. Successful outcome was obtained by combined ET/ESWL in 67 of the 98 patients (74.5%, by EHL in 7 of 14 patients (7.1%, and by outpatient ESWL in 6 of 6 patients (6.1%. Negotiating the guidewire through a severe MPD stricture was significantly associated with a higher rate of stone fragmentation (P=0.0003. Conclusions. In cases where combined ET/ESWL was not successful for stone clearance, EHL using the SpyGlass system or X-ray guided EHL was effective in cases where the guidewire could be negotiated through the MPD stricture and it increased the fragmentation rate.

  18. Investigation of magnetically smart films applied to correct the surface profile of light weight X-ray optics in two directions

    Science.gov (United States)

    Wang, Xiaoli; Yao, Youwei; Cao, Jian; Vaynman, Semyon; Graham, Michael E.; Liu, Tianchen; Ulmer, M. P.

    2015-09-01

    Our goal is to improve initially fabricated X-ray optics figures by applying a magnetic field to drive a magnetic smart material (MSM) coating on the non-reflecting side of the mirror. The consequent deformation of the surface should be three-dimensional. Here we will report on the results of working with a glass sample of 50x50x0.2 mm that has been coated with MSMs. The coated glass can be deformed in 3 dimensions and its surface profile was measured under our Zygo NewView white light interferometer (WLI). The driving magnetic field was produced via a pseudo-magnetic write head made up of two permanent magnet posts. The magnet posts were moved about the bottom of the glass sample with a 3-d computer controlled translation stage. The system allowed four degrees of freedom of motion, i.e., up and down, side to side, back and forth, and rotation of the posts (3.175 mm diameter) about the vertical axis to allow us to change the orientation of the magnetic field in the (horizontal) plane of the sample. We established a finite element analysis (FEA) model to predict deformations and compare with the observed results in order to guide the application of the magnetically controlled MSMs to improve the future X-ray optics figures.

  19. Design studies for ITER x-ray diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Hill, K.W.; Bitter, M.; von Goeler, S.; Hsuan, H.

    1995-01-01

    Concepts for adapting conventional tokamak x-ray diagnostics to the harsh radiation environment of ITER include use of grazing-incidence (GI) x-ray mirrors or man-made Bragg multilayer (ML) elements to remove the x-ray beam from the neutron beam, or use of bundles of glass-capillary x-ray ``light pipes`` embedded in radiation shields to reduce the neutron/gamma-ray fluxes onto the detectors while maintaining usable x-ray throughput. The x-ray optical element with the broadest bandwidth and highest throughput, the GI mirror, can provide adequate lateral deflection (10 cm for a deflected-path length of 8 m) at x-ray energies up to 12, 22, or 30 keV for one, two, or three deflections, respectively. This element can be used with the broad band, high intensity x-ray imaging system (XIS), the pulseheight analysis (PHA) survey spectrometer, or the high resolution Johann x-ray crystal spectrometer (XCS), which is used for ion-temperature measurement. The ML mirrors can isolate the detector from the neutron beam with a single deflection for energies up to 50 keV, but have much narrower bandwidth and lower x-ray power throughput than do the GI mirrors; they are unsuitable for use with the XIS or PHA, but they could be used with the XCS; in particular, these deflectors could be used between ITER and the biological shield to avoid direct plasma neutron streaming through the biological shield. Graded-d ML mirrors have good reflectivity from 20 to 70 keV, but still at grazing angles (<3 mrad). The efficiency at 70 keV for double reflection (10 percent), as required for adequate separation of the x-ray and neutron beams, is high enough for PHA requirements, but not for the XIS. Further optimization may be possible.

  20. Towards multi-order hard X-ray imaging with multilayer zone plates.

    Science.gov (United States)

    Osterhoff, Markus; Eberl, Christian; Döring, Florian; Wilke, Robin N; Wallentin, Jesper; Krebs, Hans-Ulrich; Sprung, Michael; Salditt, Tim

    2015-02-01

    This article describes holographic imaging experiments using a hard X-ray multilayer zone plate (MZP) with an outermost zone width of 10 nm at a photon energy of 18 keV. An order-sorting aperture (OSA) is omitted and emulated during data analysis by a 'software OSA'. Scanning transmission X-ray microscopy usually carried out in the focal plane is generalized to the holographic regime. The MZP focus is characterized by a three-plane phase-retrieval algorithm to an FWHM of 10 nm.

  1. Planetary X-ray studies: past, present and future

    Science.gov (United States)

    Branduardi-Raymont, Graziella

    2016-07-01

    Our solar system is a fascinating physics laboratory and X-ray observations are now firmly established as a powerful diagnostic tool of the multiple processes taking place in it. The science that X-rays reveal encompasses solar, space plasma and planetary physics, and the response of bodies in the solar system to the impact of the Sun's activity. This talk will review what we know from past observations and what we expect to learn in the short, medium and long term. Observations with Chandra and XMM-Newton have demonstrated that the origin of Jupiter's bright soft X-ray aurorae lies in the Charge eXchange (CX) process, likely to involve the interaction with atmospheric neutrals of local magnetospheric ions, as well as those carried in the solar wind. At higher energies electron bremsstrahlung is thought to be the X-ray emitting mechanism, while the whole planetary disk acts as a mirror for the solar X-ray flux via Thomson and fluorescent scattering. This 'X-ray mirror' phenomenon is all that is observed from Saturn's disk, which otherwise lacks X-ray auroral features. The Earth's X-ray aurora is bright and variable and mostly due to electron bremsstrahlung and line emission from atmospheric species. Un-magnetised planets, Venus and Mars, do not show X-ray aurorae but display the interesting combination of mirroring the solar X-ray flux and producing X-rays by Solar Wind Charge eXchange (SWCX) in their exospheres. These processes respond to different solar stimulation (photons and solar wind plasma respectively) hence their relative contributions are seen to vary according to the Sun's output. Present and future of planetary X-ray studies are very bright. We are preparing for the arrival of the Juno mission at Jupiter this summer and for coordinated observations with Chandra and XMM-Newton on the approach and later during Juno's orbital phase. These will allow direct correlation of the local plasma conditions with the X-ray emissions and the establishment of the

  2. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors

  3. Modeling X-ray Emission Around Galaxies

    CERN Document Server

    Anderson, Michael E

    2014-01-01

    Extended X-ray emission can be studied either spatially (through its surface brightness profile) or spectrally (by analyzing the spectrum at various locations in the field). Both techniques have advantages and disadvantages, and when the emission becomes particularly faint and/or extended, the two methods can disagree. We argue that an ideal approach would be to model the events file directly, and therefore to use both the spectral and spatial information which are simultaneously available for each event. In this work we propose a first step in this direction, introducing a method for spatial analysis which can be extended to leverage spectral information simultaneously. We construct a model for the entire X-ray image in a given energy band, and generate a likelihood function to compare the model to the data. A critical goal of this modeling is disentangling vignetted and unvignetted backgrounds through their different spatial distributions. Employing either maximum likelihood or Markov Chain Monte Carlo, we ...

  4. Evidence for the Galactic X-ray Bulge, 2

    CERN Document Server

    Park, S; Dame, T M

    1998-01-01

    A mosaic of 5 \\ros~PSPC pointed observations in the Galactic plane ($l\\sim25^{\\circ}$) reveals X-ray shadows in the $0.5-2.0$ keV band cast by distant molecular clouds. The observed on-cloud and off-cloud X-ray fluxes indicate that $\\sim15$% and $\\sim37$% of the diffuse X-ray background in this direction in the \\tq~keV and 1.5 keV bands, respectively, originates behind the molecular gas which is located at $\\sim$3 kpc from the Sun. The implication of the derived background X-ray flux beyond the absorbing molecular cloud is consistent with, and lends further support to recent observations of a Galactic X-ray bulge.

  5. High Resolution X-ray-Induced Acoustic Tomography

    Science.gov (United States)

    Xiang, Liangzhong; Tang, Shanshan; Ahmad, Moiz; Xing, Lei

    2016-05-01

    Absorption based CT imaging has been an invaluable tool in medical diagnosis, biology, and materials science. However, CT requires a large set of projection data and high radiation dose to achieve superior image quality. In this letter, we report a new imaging modality, X-ray Induced Acoustic Tomography (XACT), which takes advantages of high sensitivity to X-ray absorption and high ultrasonic resolution in a single modality. A single projection X-ray exposure is sufficient to generate acoustic signals in 3D space because the X-ray generated acoustic waves are of a spherical nature and propagate in all directions from their point of generation. We demonstrate the successful reconstruction of gold fiducial markers with a spatial resolution of about 350 μm. XACT reveals a new imaging mechanism and provides uncharted opportunities for structural determination with X-ray.

  6. X-ray Echo Spectroscopy

    Science.gov (United States)

    Shvyd'ko, Yuri

    2016-02-01

    X-ray echo spectroscopy, a counterpart of neutron spin echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a pointlike x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-0.02 meV ultrahigh-resolution IXS applications (resolving power >108 ) with broadband ≃5 - 13 meV dispersing systems are introduced featuring more than 103 signal enhancement. The technique is general, applicable in different photon frequency domains.

  7. X-ray echo spectroscopy

    CERN Document Server

    Shvyd'ko, Yuri

    2015-01-01

    X-ray echo spectroscopy, a counterpart of neutron spin-echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a point-like x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x-rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1--0.02-meV ultra-high-resolution IXS applications (resolving power $> 10^8$) with broadband $\\simeq$~5--13~meV dispersing systems are introduced featuring more than $10^3$ signal e...

  8. X-ray Echo Spectroscopy.

    Science.gov (United States)

    Shvyd'ko, Yuri

    2016-02-26

    X-ray echo spectroscopy, a counterpart of neutron spin echo, is being introduced here to overcome limitations in spectral resolution and weak signals of the traditional inelastic x-ray scattering (IXS) probes. An image of a pointlike x-ray source is defocused by a dispersing system comprised of asymmetrically cut specially arranged Bragg diffracting crystals. The defocused image is refocused into a point (echo) in a time-reversal dispersing system. If the defocused beam is inelastically scattered from a sample, the echo signal acquires a spatial distribution, which is a map of the inelastic scattering spectrum. The spectral resolution of the echo spectroscopy does not rely on the monochromaticity of the x rays, ensuring strong signals along with a very high spectral resolution. Particular schemes of x-ray echo spectrometers for 0.1-0.02 meV ultrahigh-resolution IXS applications (resolving power >10^{8}) with broadband ≃5-13  meV dispersing systems are introduced featuring more than 10^{3} signal enhancement. The technique is general, applicable in different photon frequency domains.

  9. Optoelectronic Picosecond Detection of Synchrotron X-rays

    Energy Technology Data Exchange (ETDEWEB)

    Durbin, Stephen M. [Purdue Univ., West Lafayette, IN (United States)

    2017-08-04

    The goal of this research program was to develop a detector that would measure x-ray time profiles with picosecond resolution. This was specifically aimed for use at x-ray synchrotrons, where x-ray pulse profiles have Gaussian time spreads of 50-100 ps (FWHM), so the successful development of such a detector with picosecond resolution would permit x-ray synchrotron studies to break through the pulse width barrier. That is, synchrotron time-resolved studies are currently limited to pump-probe studies that cannot reveal dynamics faster than ~50 ps, whereas the proposed detector would push this into the physically important 1 ps domain. The results of this research effort, described in detail below, are twofold: 1) the original plan to rely on converting electronic signals from a semiconductor sensor into an optical signal proved to be insufficient for generating signals with the necessary time resolution and sensitivity to be widely applicable; and 2) an all-optical method was discovered whereby the x-rays are directly absorbed in an optoelectronic material, lithium tantalate, which can then be probed by laser pulses with the desired picosecond sensitivity for detection of synchrotron x-rays. This research program has also produced new fundamental understanding of the interaction of x-rays and optical lasers in materials that has now created a viable path for true picosecond detection of synchrotron x-rays.

  10. Neutron and X-ray Detectors

    Energy Technology Data Exchange (ETDEWEB)

    Carini, Gabriella [SLAC National Accelerator Lab., Menlo Park, CA (United States); Denes, Peter [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Gruener, Sol [Cornell Univ., Ithaca, NY (United States); Lessner, Elianne [Dept. of Energy (DOE), Washington DC (United States). Office of Science Office of Basic Energy Sciences

    2012-08-01

    (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors

  11. Direct Observations of Austenite, Bainite and Martensite Formation During Arc Welding of 1045 Steel using Time Resolved X-Ray Diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Elmer, J; Palmer, T; Babu, S; Zhang, W; DebRoy, T

    2004-02-17

    In-situ Time Resolved X-Ray Diffraction (TRXRD) experiments were performed during stationary gas tungsten arc (GTA) welding of AISI 1045 C-Mn steel. These synchrotron-based experiments tracked, in real time, phase transformations in the heat-affected zone of the weld under rapid heating and cooling conditions. The diffraction patterns were recorded at 100 ms intervals, and were later analyzed using diffraction peak profile analysis to determine the relative fraction of ferrite ({alpha}) and austenite ({gamma}) phases in each diffraction pattern. Lattice parameters and diffraction peak widths were also measured throughout the heating and cooling cycle of the weld, providing additional information about the phases that were formed. The experimental results were coupled with a thermofluid weld model to calculate the weld temperatures, allowing time-temperature transformation kinetics of the {alpha} {yields} {gamma} phase transformation to be evaluated. During heating, complete austenitization was observed in the heat affected zone of the weld and the kinetics of the {alpha} {yields} {gamma} phase transformation were modeled using a Johnson-Mehl-Avrami (JMA) approach. The results from the 1045 steel weld were compared to those of a 1005 low carbon steel from a previous study. Differences in austenitization rates of the two steels were attributed to differences in the base metal microstructures, particularly the relative amounts of pearlite and the extent of the allotriomorphic ferrite phase. During weld cooling, the austenite transformed to a mixture of bainite and martensite. In situ diffraction was able to distinguish between these two non-equilibrium phases based on differences in their lattice parameters and their transformation rates, resulting in the first real time x-ray diffraction observations of bainite and martensite formation made during welding.

  12. X-ray imaging: Perovskites target X-ray detection

    Science.gov (United States)

    Heiss, Wolfgang; Brabec, Christoph

    2016-05-01

    Single crystals of perovskites are currently of interest to help fathom fundamental physical parameters limiting the performance of perovskite-based polycrystalline solar cells. Now, such perovskites offer a technology platform for optoelectronic devices, such as cheap and sensitive X-ray detectors.

  13. Portable X-Ray Device

    Science.gov (United States)

    1983-01-01

    Portable x-ray instrument developed by NASA now being produced commercially as an industrial tool may soon find further utility as a medical system. The instrument is Lixiscope - Low Intensity X-Ray Imaging Scope -- a self-contained, battery-powered fluoroscope that produces an instant image through use of a small amount of radioactive isotope. Originally developed by Goddard Space Flight Center, Lixiscope is now being produced by Lixi, Inc. which has an exclusive NASA license for one version of the device.

  14. Benefits of X-Ray CMT for the modeling of C/C composites

    Energy Technology Data Exchange (ETDEWEB)

    Coindreau, Olivia; Lachaud, Jean; Vignoles, Gerard L. [LCTS - UMR 5801 CNRS-Universite Bordeaux 1-Safran-CEA 3, Allee La Boetie, Pessac, F33600 (France); Mulat, Christianne [LCTS - UMR 5801 CNRS-Universite Bordeaux 1-Safran-CEA 3, Allee La Boetie, Pessac, F33600 (France); IMS - UMR5218 CNRS-Universite Bordeaux 1-IPB 351, Avenue de la Liberation, Talence, F33410 (France); Germain, Christian [IMS - UMR5218 CNRS-Universite Bordeaux 1-IPB 351, Avenue de la Liberation, Talence, F33410 (France)

    2011-03-15

    C/C composites have application in very demanding areas like aerospace, fusion technology, etc. and thus their optimization is crucial, both in the control of processing routes and in the prediction of their behavior in use. Intense modeling efforts have been performed in these directions. To help a direct application on actual materials, with possibly complex reinforcement architectures, X-ray computerized micro-tomography (CMT) is a beneficial technique, since it allows producing extremely detailed representations of these architectures. However, there is a long way from the crude X-ray projections to the information that is directly usable in C/C composite modeling. This paper summarizes several achievements in this domain and discusses the obtained results, concerning (i) composites imaging by phase contrast CMT and holographic CMT, (ii) evaluation of effective geometrical and transfer properties in fiber arrangements and actual fiber-reinforced composites, (iii) modeling of degradation by ablation, and (iv) modeling of processing by chemical vapor infiltration. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. X-ray diagnostics of massive star winds

    Science.gov (United States)

    Oskinova, Lidia M.

    2016-09-01

    Nearly all types of massive stars with radiatively driven stellar winds are X-ray sources that can be observed by the presently operating powerful X-ray telescopes. In this review I briefly address recent advances in our understanding of stellar winds obtained from X-ray observations. X-rays may strongly influence the dynamics of weak winds of main sequence B-type stars. X-ray pulsations were detected in a β Cep type variable giving evidence of tight photosphere-wind connections. The winds of OB dwarfs with subtypes later than O9V may be predominantly in a hot phase, and X-ray observations offer the best window for their studies. The X-ray properties of OB supergiants are largely determined by the effects of radiative transfer in their clumped stellar winds. The recently suggested method to directly measure mass-loss rates of O stars by fitting the shapes of X-ray emission lines is considered but its validity cannot be confirmed. To obtain robust quantitative information on stellar wind parameters from X-ray spectroscopy, a multiwavelength analysis by means of stellar atmosphere models is required. Independent groups are now performing such analyses with encouraging results. Joint analyses of optical, UV, and X-ray spectra of OB supergiants yield consistent mass-loss rates. Depending on the adopted clumping parameters, the empirically derived mass-loss rates are a factor of a few smaller or comparable to those predicted by standard recipes (Vink et al., 2001). All sufficiently studied O stars display variable X-ray emission that might be related to corotating interaction regions in their winds. In the latest stages of stellar evolution, single red supergiants (RSG) and luminous blue variable (LBV) stars do not emit observable amounts of X-rays. On the other hand, nearly all types of Wolf-Rayet (WR) stars are X-ray sources. X-ray spectroscopy allows a sensitive probe of WR wind abundances and opacities.

  16. X-ray Compton line scan tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kupsch, Andreas; Lange, Axel; Jaenisch, Gerd-Ruediger [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany). Fachgruppe 8.5 - Mikro-ZfP; Hentschel, Manfred P. [Technische Univ. Berlin (Germany); Kardjilov, Nikolay; Markoetter, Henning; Hilger, Andre; Manke, Ingo [Helmholtz-Zentrum Berlin (HZB) (Germany); Toetzke, Christian [Potsdam Univ. (Germany)

    2015-07-01

    The potentials of incoherent X-ray scattering (Compton) computed tomography (CT) are investigated. The imaging of materials of very different atomic number or density at once is generally a perpetual challenge for X-ray tomography or radiography. In a basic laboratory set-up for simultaneous perpendicular Compton scattering and direct beam attenuation tomography are conducted by single channel photon counting line scans. This results in asymmetric distortions of the projection profiles of the scattering CT data set. In a first approach, corrections of Compton scattering data by taking advantage of rotational symmetry yield tomograms without major geometric artefacts. A cylindrical sample composed of PE, PA, PVC, glass and wood demonstrates similar Compton contrast for all the substances, while the conventional absorption tomogram only reveals the two high order materials. Comparison to neutron tomography reveals astonishing similarities except for the glass component (without hydrogen). Therefore, Compton CT offers the potential to replace neutron tomography, which requires much more efforts.

  17. Design of folded holographic spectrum-splitting photovoltaic system for direct and diffuse illumination conditions

    Science.gov (United States)

    Wu, Yuechen; Vorndran, Shelby D.; Russo, Juan M.; Ayala, Silvana; Kostuk, Raymond K.

    2014-10-01

    Spectrum-splitting is a beneficial technique to increase the efficiency and reduce the cost of photovoltaic (PV) systems. This method divides the incident solar spectrum into spectral components that are spatially separated and directed to PV cells with matching spectral responsivity characteristics. This approach eliminates problems associated with current and lattice matching that must be maintained in tandem multi-junction systems. In this paper, a two-junction holographic spectrum-splitting photovoltaic system is demonstrated with a folded PV geometry. The system is designed to use both direct and diffuse solar irradiation. It consists of holographic elements, a wedge-shaped optical guide, and PV substrates with back reflectors. The holographic elements and back reflectors spatially separate the incident solar spectrum and project spectral components onto matching PV cell types. In addition, the wedge-shaped optical guide traps diffuse illumination inside the system to increase absorption. In this paper, the wedge spectrum splitting system is analyzed using tabulated data for InGaP2/GaAs cells with direct illumination combined with experimental data for reflection volume holograms. A system efficiency of 31.42% is obtained with experimental reflection hologram data. This efficiency is a 21.42% improvement over a similar system that uses one PV cell with the highest efficiency (GaAs). Simulation results show large acceptance angle for both in-plane and out-of plane directions. Simulation of the output power of the system with different configurations at different times of the year are also presented.

  18. Neutron Stars in X-ray Binaries and their Environments

    Science.gov (United States)

    Paul, Biswajit

    2017-09-01

    Neutron stars in X-ray binary systems are fascinating objects that display a wide range of timing and spectral phenomena in the X-rays. Not only parameters of the neutron stars, like magnetic field strength and spin period evolve in their active binary phase, the neutron stars also affect the binary systems and their immediate surroundings in many ways. Here we discuss some aspects of the interactions of the neutron stars with their environments that are revelaed from their X-ray emission. We discuss some recent developments involving the process of accretion onto high magnetic field neutron stars: accretion stream structure and formation, shape of pulse profile and its changes with accretion torque. Various recent studies of reprocessing of X-rays in the accretion disk surface, vertical structures of the accretion disk and wind of companion star are also discussed here. The X-ray pulsars among the binary neutron stars provide excellent handle to make accurate measurement of the orbital parameters and thus also evolution of the binray orbits that take place over time scale of a fraction of a million years to tens of millions of years. The orbital period evolution of X-ray binaries have shown them to be rather complex systems. Orbital evolution of X-ray binaries can also be carried out from timing of the X-ray eclipses and there have been some surprising results in that direction, including orbital period glitches in two X-ray binaries and possible detection of the most massive circum-binary planet around a Low Mass X-ray Binary.

  19. Comparing neutron and X-ray images from NIF implosions

    Directory of Open Access Journals (Sweden)

    Wilson D.C.

    2013-11-01

    Full Text Available Directly laser driven and X-radiation driven DT filled capsules differ in the relationship between neutron and X-ray images. Shot N110217, a directly driven DT-filled glass micro-balloon provided the first neutron images at the National Ignition Facility. As seen in implosions on the Omega laser, the neutron image can be enclosed inside time integrated X-ray images. HYDRA simulations show the X-ray image is dominated by emission from the hot glass shell while the neutron image arises from the DT fuel it encloses. In the absence of mix or jetting, X-ray images of a cryogenically layered THD fuel capsule should be dominated by emission from the hydrogen rather than the cooler plastic shell that is separated from the hot core by cold DT fuel. This cool, dense DT, invisible in X-ray emission, shows itself by scattering hot core neutrons. Germanium X-ray emission spectra and Ross pair filtered X-ray energy resolved images suggest that germanium doped plastic emits in the torus shaped hot spot, probably reducing the neutron yield.

  20. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ... This ensures that those parts of a patient's body not being imaged receive minimal radiation ... x-ray images are among the clearest, most detailed views of ...

  1. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... encourage linking to this site. × Recommend RadiologyInfo to a friend Send to (friend's e-mail address): From ( ...

  2. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z X-ray ( ... are the fastest and easiest way for your doctor to view and assess bone fractures, injuries and ...

  3. X-Ray Diffractive Optics

    Science.gov (United States)

    Dennis, Brian; Li, Mary; Skinner, Gerald

    2013-01-01

    X-ray optics were fabricated with the capability of imaging solar x-ray sources with better than 0.1 arcsecond angular resolution, over an order of magnitude finer than is currently possible. Such images would provide a new window into the little-understood energy release and particle acceleration regions in solar flares. They constitute one of the most promising ways to probe these regions in the solar atmosphere with the sensitivity and angular resolution needed to better understand the physical processes involved. A circular slit structure with widths as fine as 0.85 micron etched in a silicon wafer 8 microns thick forms a phase zone plate version of a Fresnel lens capable of focusing approx. =.6 keV x-rays. The focal length of the 3-cm diameter lenses is 100 microns, and the angular resolution capability is better than 0.1 arcsecond. Such phase zone plates were fabricated in Goddard fs Detector Development Lab. (DDL) and tested at the Goddard 600-microns x-ray test facility. The test data verified that the desired angular resolution and throughput efficiency were achieved.

  4. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... and places the x-ray film holder or digital recording plate under the table in the area of the body being imaged. When necessary, sandbags, pillows or other positioning devices will be used to help you maintain the ...

  5. Alpha proton x ray spectrometer

    Science.gov (United States)

    Rieder, Rudi; Waeke, H.; Economou, T.

    1994-01-01

    Mars Pathfinder will carry an alpha-proton x ray spectrometer (APX) for the determination of the elemental chemical composition of Martian rocks and soils. The instrument will measure the concentration of all major and some minor elements, including C, N, and O at levels above typically 1 percent.

  6. X-ray backscatter imaging

    Science.gov (United States)

    Dinca, Dan-Cristian; Schubert, Jeffrey R.; Callerame, J.

    2008-04-01

    In contrast to transmission X-ray imaging systems where inspected objects must pass between source and detector, Compton backscatter imaging allows both the illuminating source as well as the X-ray detector to be on the same side of the target object, enabling the inspection to occur rapidly and in a wide variety of space-constrained situations. A Compton backscatter image is similar to a photograph of the contents of a closed container, taken through the container walls, and highlights low atomic number materials such as explosives, drugs, and alcohol, which appear as especially bright objects by virtue of their scattering characteristics. Techniques for producing X-ray images based on Compton scattering will be discussed, along with examples of how these systems are used for both novel security applications and for the detection of contraband materials at ports and borders. Differences between transmission and backscatter images will also be highlighted. In addition, tradeoffs between Compton backscatter image quality and scan speed, effective penetration, and X-ray source specifications will be discussed.

  7. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  8. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... for more information about pregnancy and x-rays. A Word About Minimizing Radiation Exposure Special care is ... encourage linking to this site. × Recommend RadiologyInfo to a friend Send to (friend's e-mail address): From ( ...

  9. Stellar X-Ray Polarimetry

    Science.gov (United States)

    Swank, J.

    2011-01-01

    Most of the stellar end-state black holes, pulsars, and white dwarfs that are X-ray sources should have polarized X-ray fluxes. The degree will depend on the relative contributions of the unresolved structures. Fluxes from accretion disks and accretion disk corona may be polarized by scattering. Beams and jets may have contributions of polarized emission in strong magnetic fields. The Gravity and Extreme Magnetism Small Explorer (GEMS) will study the effects on polarization of strong gravity of black holes and strong magnetism of neutron stars. Some part of the flux from compact stars accreting from companion stars has been reflected from the companion, its wind, or accretion streams. Polarization of this component is a potential tool for studying the structure of the gas in these binary systems. Polarization due to scattering can also be present in X-ray emission from white dwarf binaries and binary normal stars such as RS CVn stars and colliding wind sources like Eta Car. Normal late type stars may have polarized flux from coronal flares. But X-ray polarization sensitivity is not at the level needed for single early type stars.

  10. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... dislocations. In elderly or patients with osteoporosis, a hip fracture may be clearly seen on a CT scan, while it may be barely seen, if at all, on a hip x-ray. For suspected spine injury or other ...

  11. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... An x-ray (radiograph) is a noninvasive medical test that helps physicians diagnose and treat medical conditions. ...

  12. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    OpenAIRE

    de Groot, F. M. F.

    2001-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption process. Section II discusses 1s X-ray absorption, i.e., the K edges, and section III deals with 2p X-ray absorption, the L edges. X-ray emission is discussed in, respectively, the L edges. X-ray emis...

  13. Direct CO(2) laser-based generation of holographic structures on the surface of glass.

    Science.gov (United States)

    Wlodarczyk, Krystian L; Weston, Nicholas J; Ardron, Marcus; Hand, Duncan P

    2016-01-25

    A customized CO(2) laser micromachining system was used for the generation of phase holographic structures directly on the surface of fused silica (HPFS(®)7980 Corning) and Borofloat(®)33 (Schott AG) glass. This process used pulses of duration 10µs and nominal wavelength 10.59µm. The pulse energy delivered to the glass workpiece was controlled by an acousto-optic modulator. The laser-generated structures were optically smooth and crack free. We demonstrated their use as diffractive optical elements (DOEs), which could be exploited as anti-counterfeiting markings embedded into valuable glass-made components and products.

  14. Optimized setup for integral refractive index direct determination applying digital holographic microscopy by reflection and transmission

    Science.gov (United States)

    Frómeta, M.; Moreno, G.; Ricardo, J.; Arias, Y.; Muramatsu, M.; Gomes, L. F.; Palácios, G.; Palácios, F.; Velázquez, H.; Valin, J. L.; Ramirez Q, L.

    2017-03-01

    In this paper the integral refractive index of a microscopic sample was directly measured by applying Digital Holographic Microscopy (DHM) capturing transmission and reflection holograms simultaneously, of the same sample's region, using Mach-Zehnder and Michelson micro interferometers for transmission and reflection holograms capture and modeling the 3D sample in a medium of known refractive index nm. The system was calibrated using standard polystyrene sphere immersed in water with known diameter and refractive index, and the method was applied for erythrocyte integral refractive index determination. The results are in accordance with predicted, the measurements error of the order of ± 0.005 in absolute values.

  15. In-line holography and coherent diffractive imaging with x-ray waveguides

    Science.gov (United States)

    de Caro, L.; Giannini, C.; Pelliccia, D.; Mocuta, C.; Metzger, T. H.; Guagliardi, A.; Cedola, A.; Burkeeva, I.; Lagomarsino, S.

    2008-02-01

    A Fresnel coherent diffraction imaging experiment with hard x rays is here presented, using two planar crossed waveguides as optical elements, leading to a virtual pointlike source. The coherent wave field obtained with this setup is used to illuminate a micrometric single object having the shape of a butterfly. A digital two-dimensional in-line holographic reconstruction of the unknown object at low resolution (200nm) has been obtained directly via fast Fourier transform (FFT) of the raw data. The object and its twin image are well separated because suitable geometrical conditions are satisfied. A good estimate of the incident wave field phase has been extracted directly from the FFT of the raw data. A partial object reconstruction with 50nm spatial resolution was achieved by fast iterative phase retrieval, the major limitation for a full reconstruction being the nonideal structure of the guided beam. The method offers a route for fast and reliable phase retrieval in x-ray coherent diffraction.

  16. High-Resolution X-ray Emission and X-ray Absorption Spectroscopy

    NARCIS (Netherlands)

    Groot, F.M.F. de

    2000-01-01

    In this review, high-resolution X-ray emission and X-ray absorption spectroscopy will be discussed. The focus is on the 3d transition-metal systems. To understand high-resolution X-ray emission and reso-nant X-ray emission, it is first necessary to spend some time discussing the X-ray absorption

  17. Radiation chemical effects of X-rays on liquids

    Energy Technology Data Exchange (ETDEWEB)

    Holroyd, R.A.; Preses, J.M.

    1998-11-01

    This review describes some of the chemical changes induced by photoelectrons which are released in liquids when X-rays are absorbed. Both experimental studies and theory are discussed. In part 1, the basic processes occurring upon absorption of X-rays are described. Parts 2 and 3 deal with hydrocarbon liquids; in part 2 the ion yields, including effects at K-edges, and in part 3, the yields of excited states. Part 4 discusses chemical effects of X-rays in aqueous solutions. The authors end with a summary of future needs and directions.

  18. A dedicated endstation for waveguide-based X-ray imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kalbfleisch, Sebastian

    2013-07-01

    X-ray microscopy has emerged as a powerful and versatile imaging technique in many fields of science over the last years, offering insights in opaque media at high spatial resolution. A major challenge remains the fabrication of suitable X-ray lenses, e.g., Fresnel zone plates or compound refractive lenses. In an alternative approach of a lensless imaging scheme the sample is illuminated by a coherent X-ray beam. The sample information is then reconstructed from the recorded diffraction signal by numerical iterative algorithms. Within this thesis the basics of lensless holographic imaging with X-Ray waveguides are summarised and extended to the concept of waveguide-based X-ray interferometry. The specific instrumentation required for the conceptual experiments of waveguidebased holographic imaging is explained and illustrated by the obtained results. Based on the results of these conceptual experiments a dedicated synchrotron endstation for waveguide-based holographic imaging was designed and built. The specifications and properties of the Kirkpatrick-Baez focussing mirrors and other mechanical and optical components are described in detail, along with the instrument control system and various available detectors. First commissioning results prove the imaging abilities of the presented endstation.

  19. X-ray reprocessing in binaries

    Science.gov (United States)

    Paul, Biswajit

    2016-07-01

    We will discuss several aspects of X-ray reprocessing into X-rays or longer wavelength radiation in different kinds of binary systems. In high mass X-ray binaries, reprocessing of hard X-rays into emission lines or lower temperature black body emission is a useful tool to investigate the reprocessing media like the stellar wind, clumpy structures in the wind, accretion disk or accretion stream. In low mass X-ray binaries, reprocessing from the surface of the companion star, the accretion disk, warps and other structures in the accretion disk produce signatures in longer wavelength radiation. X-ray sources with temporal structures like the X-ray pulsars and thermonuclear burst sources are key in such studies. We will discuss results from several new investigations of X-ray reprocessing phenomena in X-ray binaries.

  20. The Classification of Extragalactic X-ray Jets

    Science.gov (United States)

    Harris, D. E.; Massaro, F.; Cheung, C. C.

    2010-07-01

    The overall classification of X-ray jets has clung to that prevalent in the radio: FRI vs. FRO (including quasars). Indeed, the common perception is that X-ray emission from FRI's is synchrotron emission whereas that from FRII's may be IC/CMB and/or synchrotron. Now that we have a sizable collection of sources with detected X-ray emission from jets and hotspots, it seems that a more unbiased study of these objects could yield additional insights on jets and their X-ray emission. The current contribution is a first step in the process of analyzing all of the relevant parameters for each detected component for the sources collected in the XJET website. This initial effort involves measuring the ratio of X-ray to radio fluxes and evaluating correlations with other jet parameters. For single zone synchrotron X-ray emission, we anticipate that larger values of fx/fr should correlate inversely with the average magnetic field strength (if the acceleration process is limited by loss time equals acceleration time). Beamed IC/CMB X-rays should produce larger values of fx/fr for smaller values of the angle between the jet direction and the line of sight but will also be affected by the low frequency radio spectral index.

  1. NSLS-II X-ray diagnostics development

    CERN Document Server

    Ilinski, Petr

    2013-01-01

    NSLS-II x-ray diagnostics will provide continuous online data of electron beam dimensions, which will be used to derive electron beam emittance and energy spread. It will also provide information of electron beam tilt for coupling evaluation. X-ray diagnostics will be based on imaging of bending magnet and three-pole wiggler synchrotron radiation sources. Diagnostics from three-pole wiggler source will be used to derive particles energy spread. Beta and dispersion functions will have to be evaluated for emittance and particles energy spread calculations. Due to small vertical source sizes imaging need to be performed in x-ray energy range. X-ray optics with high numerical aperture, such as compound refractive lens, will be used to achieve required spatial resolution. Optical setups with different magnifications in horizontal and vertical directions fill be employed to deal with large aspect ratio of the source. X-ray diagnostics setup will include x-ray imaging optics, monochromatization, x-ray imaging and re...

  2. X-ray diagnostics of massive star winds

    CERN Document Server

    Oskinova, Lidia

    2016-01-01

    Nearly all types of massive stars with radiatively driven stellar winds are X-ray sources that can be observed by the presently operating powerful X-ray telescopes. In this review I briefly address recent advances in our understanding of stellar winds obtained from X-ray observations. The winds of OB dwarfs with subtypes later than O9V may be predominantly in a hot phase, and X-ray observations offer the best window for their studies. The X-ray properties of OB supergiants are largely determined by the effects of radiative transfer in their clumped stellar winds. The recently suggested method to directly measure mass-loss rates of O stars by fitting the shapes of X-ray emission lines is considered but its validity cannot be confirmed. To obtain robust quantitative information on stellar wind parameters from X-ray spectroscopy, a multiwavelength analysis by means of stellar atmosphere models is required. Independent groups are now performing such analyses with encouraging results. Joint analyses of optical, UV...

  3. X-ray structures of recombinant yeast cytochrome c peroxidase and three heme-cleft mutants prepared by site-directed mutagenesis

    Energy Technology Data Exchange (ETDEWEB)

    Wang, J.; Mauro, J.M.; Edwards, S.L.; Oatley, S.J.; Fishel, L.A.; Ashford, V.A.; Xuong, Nguyenhuu; Kraut, J. (Univ. of California at San Diego, La Jolla (USA))

    1990-08-07

    The 2.2-{angstrom} x-ray structure for CCP(MI), a plasmid-encoded form of Saccharomyces cerevisiae cytochrome c peroxidase (CCP) expressed in Escherichia coli has been solved, together with the structures of three specifically designed single-site heme-cleft mutants. The structure of CCP(MI) was solved by using molecular replacement methods, since its crystals grow differently from the crystals of CCP isolated from bakers' yeast used previously for structural solution. Small distal-side differences between CCP(MI) and bakers' yeast CCP are observed, presumably due to a strain-specific Thr-53 {yields} Ile substitution in CCP(MI). The observation of a vacant sixth coordination site in this structure differs from the results of solution resonance Raman studies, which predict hexacoordinated high-spin iron. The coordination behavior of this W51F mutant is apparently altered in the presence of a precipitating agent, 30% 2-methyl-2,4-pentanediol. A proximal Trp-191 {yields} Phe mutant that has substantially diminished enzyme activity and altered magnetic properties accommodates the substitution by allowing the side chain of Phe-191, together with the segment of backbone to which it is attached, to move toward the heme. This relatively large local perturbation is accompanied by numerous small adjustments resulting in a slight overall compression of the enzyme's proximal domain; however, the iron coordination sphere is essentially unchanged. This structures rules out a major alteration in protein conformation as a reason for the dramatically decreased activity of the W191F mutant. From the alteration of local structure that occurs in this mutant, coupled with the results of preliminary functional studies, the authors infer that Asp-235 exerts influence on the heme iron so as to keep its sixth coordination site vacant, and hence reactive with peroxide substrate, over a wide pH range.

  4. Theory of time-resolved inelastic x-ray diffraction

    DEFF Research Database (Denmark)

    Lorenz, Ulf; Møller, Klaus Braagaard; Henriksen, Niels Engholm

    2010-01-01

    Starting from a general theory of time-resolved x-ray scattering, we derive a convenient expression for the diffraction signal based on a careful analysis of the relevant inelastic scattering processes. We demonstrate that the resulting inelastic limit applies to a wider variety of experimental...... conditions than similar, previously derived formulas, and it directly allows the application of selection rules when interpreting diffraction signals. Furthermore, we present a simple extension to systems simultaneously illuminated by x rays and a laser beam....

  5. X-ray high temperature study of interphase strains in directionally crystallized eutectics. [Heat resisting alloys:Ni-Cr-Co-Al-Ti-Mo-W, and Co-Cr-Ni

    Energy Technology Data Exchange (ETDEWEB)

    Samojlov, A.I.; Ignatova, I.A.; Khatsinskaya, I.M.; Dodonova, L.P.; Krivko, A.I.; Kozlova, V.S.

    1981-01-01

    The technique of the determination of thermal interphase strains in the matrix and reinforced phases of directionally crystallized composits (eutectics) is developed. On the basis of previously suggested general principles of calculation tested at room temperature on the eutectics ..gamma../..gamma..'- MC the peculiarities and regularities of the formation of the strained state of phases (in Ni-Cr-Co-Al-Ti-Mo-W and Co-Cr-Ni alloys ..gamma../..gamma..' - MC and CoTaC-3) in a wide temperature range from the formation temperature to the room one are presented. On the basis of experimentally determined temperature dependence of X-ray strain of the matrix phase and adopted structural model the method of the determination of the level and sign of strains during the heating and cooling of the material in the given temperature range is presented. The existence of hysteresis of the curves of the sigmasub(i)=sigmasub(i)(T) dependences, characteristic of the given composite is established. The results of X-ray tensometry are compared with the results of dilatometric studies of the same eutectics.

  6. Direct imaging by atomic force microscopy of surface-localized self-assembled monolayers on a cuprate superconductor and surface X-ray scattering analysis of analogous monolayers on the surface of water

    Energy Technology Data Exchange (ETDEWEB)

    Schougaard, Steen B. [Departement de Chimie, Universite du Quebec a Montreal, Case postale 8888, Succ. Centre-ville, Montreal, Quebec, H3C 3P8 (Canada); Texas Materials Institute, Center for Nano and Molecular Science and Engineering, Department Chemistry and Biochemistry, University of Texas at Austin, Austin, TX, 78722 (United States)], E-mail: schougaard.steen@uqam.ca; Reitzel, Niels; Bjornholm, Thomas [Nano-Science Center, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen (Denmark); Kjaer, Kristian [Max-Planck Institute of Colloids and Interfaces, Am Muehlenberg, D-14476 Potsdam (Germany); Niels Bohr Institute, University of Copenhagen, Universitetsparken 5, DK-2100 Copenhagen (Denmark); Jensen, Torben R. [Interdisciplinary Nanoscience Center (iNANO), Department of Chemistry, University of Aarhus, DK-8000 Aarhus C (Denmark); Shmakova, Olga E.; Colorado, Ramon; Lee, T. Randall [Department of Chemistry, University of Houston, Houston, TX 77204-5003 (United States); Choi, J.-H.; Markert, John T.; Derro, David; Lozanne, Alex de [Department of Physics, University of Texas at Austin, Austin, TX 78712-1081 (United States); McDevitt, John T. [Texas Materials Institute, Center for Nano and Molecular Science and Engineering, Department Chemistry and Biochemistry, University of Texas at Austin, Austin, TX, 78722 (United States)

    2007-09-14

    A self-assembled monolayer of CF{sub 3}(CF{sub 2}){sub 3}(CH{sub 2}){sub 11}NH{sub 2} atop the (001) surface of the high-temperature superconductor YBa{sub 2}Cu{sub 3}O{sub 7-x} was imaged by atomic force microscopy (AFM). The AFM images provide direct 2D-structural evidence for the epitaxial 5.5 A square {radical}2 x {radical}2R45{sup o} unit cell previously predicted for alkyl amines by molecular modeling [J.E. Ritchie, C.A. Wells, J.-P. Zhou, J. Zhao, J.T. McDevitt, C.R. Ankrum, L. Jean, D.R. Kanis, J. Am. Chem. Soc. 120 (1998) 2733]. Additionally, the 3D structure of an analogous Langmuir monolayer of CF{sub 3}(CF{sub 2}){sub 9}(CH{sub 2}){sub 11}NH{sub 2} on water was studied by grazing-incidence X-ray diffraction and specular X-ray reflectivity. Structural differences and similarities between the water-supported and superconductor-localized monolayers are discussed.

  7. An intraoral miniature x-ray tube based on carbon nanotubes for dental radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Jin; Kim, Hyun Nam; Raza, Hamid Saeed; Park, Han Beom; Cho, Sung Oh [Dept. of Nuclear and Quantum Engineering, Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2016-06-15

    A miniature X-ray tube based on a carbon-nanotube electron emitter has been employed for the application to a dental radiography. The miniature X-ray tube has an outer diameter of 7 mm and a length of 47 mm. The miniature X-ray tube is operated in a negative high-voltage mode in which the X-ray target is electrically grounded. In addition, X-rays are generated only to the teeth directions using a collimator while X-rays generated to other directions are shielded. Hence, the X-ray tube can be safely inserted into a human mouth. Using the intra-oral X-ray tube, a dental radiography is demonstrated where the positions of an X-ray source and a sensor are reversed compared with a conventional dental radiography system. X-ray images of five neighboring teeth are obtained and, furthermore, both left and right molar images are achieved by a single X-ray shot of the miniature X-ray tube.

  8. X-Ray-powered Macronovae

    Science.gov (United States)

    Kisaka, Shota; Ioka, Kunihito; Nakar, Ehud

    2016-02-01

    A macronova (or kilonova) was observed as an infrared excess several days after the short gamma-ray burst GRB 130603B. Although the r-process radioactivity is widely discussed as an energy source, it requires a huge mass of ejecta from a neutron star (NS) binary merger. We propose a new model in which the X-ray excess gives rise to the simultaneously observed infrared excess via thermal re-emission, and explore what constraints this would place on the mass and velocity of the ejecta. This X-ray-powered model explains both the X-ray and infrared excesses with a single energy source such as the central engine like a black hole, and allows for a broader parameter region than the previous models, in particular a smaller ejecta mass ˜ {10}-3{--}{10}-2{M}⊙ and higher iron abundance mixed as suggested by general relativistic simulations for typical NS-NS mergers. We also discuss the other macronova candidates in GRB 060614 and GRB 080503, and the implications for the search of electromagnetic counterparts to gravitational waves.

  9. Be/X-ray binaries

    CERN Document Server

    Reig, Pablo

    2011-01-01

    The purpose of this work is to review the observational properties of Be/X-ray binaries. The open questions in Be/X-ray binaries include those related to the Be star companion, that is, the so-called "Be phenomenon", such as, timescales associated to the formation and dissipation of the equatorial disc, mass-ejection mechanisms, V/R variability, and rotation rates; those related to the neutron star, such as, mass determination, accretion physics, and spin period evolution; but also, those that result from the interaction of the two constituents, such as, disc truncation and mass transfer. Until recently, it was thought that the Be stars' disc was not significantly affected by the neutron star. In this review, I present the observational evidence accumulated in recent years on the interaction between the circumstellar disc and the compact companion. The most obvious effect is the tidal truncation of the disc. As a result, the equatorial discs in Be/X-ray binaries are smaller and denser than those around isolat...

  10. X-Ray Crystallography Reagent

    Science.gov (United States)

    Morrison, Dennis R. (Inventor); Mosier, Benjamin (Inventor)

    2003-01-01

    Microcapsules prepared by encapsulating an aqueous solution of a protein, drug or other bioactive substance inside a semi-permeable membrane by are disclosed. The microcapsules are formed by interfacial coacervation under conditions where the shear forces are limited to 0-100 dynes per square centimeter at the interface. By placing the microcapsules in a high osmotic dewatering solution. the protein solution is gradually made saturated and then supersaturated. and the controlled nucleation and crystallization of the protein is achieved. The crystal-filled microcapsules prepared by this method can be conveniently harvested and stored while keeping the encapsulated crystals in essentially pristine condition due to the rugged. protective membrane. Because the membrane components themselves are x-ray transparent, large crystal-containing microcapsules can be individually selected, mounted in x-ray capillary tubes and subjected to high energy x-ray diffraction studies to determine the 3-D smucture of the protein molecules. Certain embodiments of the microcapsules of the invention have composite polymeric outer membranes which are somewhat elastic, water insoluble, permeable only to water, salts, and low molecular weight molecules and are structurally stable in fluid shear forces typically encountered in the human vascular system.

  11. Direct observation of temperature dependent magnetic domain structure of the multiferroic La{sub 0.66}Sr{sub 0.34}MnO{sub 3}/BiFeO{sub 3} bilayer system by x-ray linear dichroism- and x-ray magnetic circular dichroism-photoemission electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Mix, C.; Finizio, S.; Jakob, G.; Kläui, M. [Institut für Physik, Johannes Gutenberg Universität Mainz, Staudingerweg 7, D-55128 Mainz (Germany); Buzzi, M.; Nolting, F. [Swiss Light Source, Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland); Kronast, F. [Helmholtz-Zentrum-Berlin für Materialien und Energie GmbH, Albert-Einstein Straße 15, D-12489 Berlin (Germany)

    2014-05-21

    Low-thickness La{sub 0.66}Sr{sub 0.34}MnO{sub 3} (LSMO)/BiFeO{sub 3} (BFO) thin film samples deposited on SrTiO{sub 3} were imaged by high resolution x-ray microscopy at different temperatures. The ultra-thin thickness of the top layer allows to image both the ferromagnetic domain structure of LSMO and the multiferroic domain structure of the buried BFO layer, opening a path to a direct observation of coupling at the interface on a microscopic level. By comparing the domain size and structure of the BFO and LSMO, we observed that, in contrast to LSMO single layers, LSMO/BFO multilayers show a strong temperature dependence of the ferromagnetic domain structure of the LSMO. Particularly, at 40 K, a similar domain size for BFO and LSMO is observed. This indicates a persistence of exchange coupling on the microscopic scale at a temperature, where the exchange bias as determined by magnetometer measurements is vanishing.

  12. Kinematics of Supernova Remnants: Status of X-Ray Observations

    CERN Document Server

    Dewey, Daniel

    2010-01-01

    A supernova (SN) explosion drives stellar debris into the circumstellar material (CSM) filling a region on a scale of parsecs with X-ray emitting plasma. The velocities involved in supernova remnants (SNRs), thousands of km/s, can be directly measured with medium and high-resolution X-ray spectrometers and add an important dimension to our understanding of the last stages of the progenitor, the explosion mechanism, and the physics of strong shocks. After touching on the ingredients of SNR kinematics, I present a summary of the still-growing measurement results from SNR X-ray observations. Given the advances in 2D/3D hydrodynamics, data analysis techniques, and especially X-ray instrumentation, it is clear that our view of SNRs will continue to deepen in the decades ahead.

  13. Kinematics of Supernova Remnants: Status of X-Ray Observations

    Science.gov (United States)

    Dewey, Daniel

    2010-12-01

    A supernova (SN) explosion drives stellar debris into the circumstellar material (CSM) filling a region on a scale of parsecs with X-ray emitting plasma. The velocities involved in supernova remnants (SNRs), thousands of km s-1, can be directly measured with medium and high-resolution X-ray spectrometers and add an important dimension to our understanding of the last stages of the progenitor, the explosion mechanism, and the physics of strong shocks. After touching on the ingredients of SNR kinematics, I present a summary of the still-growing measurement results from SNR X-ray observations. Given the advances in 2D/3D hydrodynamics, data analysis techniques, and especially X-ray instrumentation, it is clear that our view of SNRs will continue to deepen in the decades ahead.

  14. Vitreous carbon mask substrate for X-ray lithography

    Science.gov (United States)

    Aigeldinger, Georg [Livermore, CA; Skala, Dawn M [Fremont, CA; Griffiths, Stewart K [Livermore, CA; Talin, Albert Alec [Livermore, CA; Losey, Matthew W [Livermore, CA; Yang, Chu-Yeu Peter [Dublin, CA

    2009-10-27

    The present invention is directed to the use of vitreous carbon as a substrate material for providing masks for X-ray lithography. The new substrate also enables a small thickness of the mask absorber used to pattern the resist, and this enables improved mask accuracy. An alternative embodiment comprised the use of vitreous carbon as a LIGA substrate wherein the VC wafer blank is etched in a reactive ion plasma after which an X-ray resist is bonded. This surface treatment provides a surface enabling good adhesion of the X-ray photoresist and subsequent nucleation and adhesion of the electrodeposited metal for LIGA mold-making while the VC substrate practically eliminates secondary radiation effects that lead to delamination of the X-ray resist form the substrate, the loss of isolated resist features, and the formation of a resist layer adjacent to the substrate that is insoluble in the developer.

  15. Chest X-Ray (Chest Radiography)

    Science.gov (United States)

    ... clothing that might interfere with the x-ray images. Women should always inform their physician and x-ray ... small burst of radiation that passes through the body, recording an image on photographic film or a special detector. Different ...

  16. X-ray image quality in radiography

    Energy Technology Data Exchange (ETDEWEB)

    Borcke, E.

    1987-01-01

    A proposal is worked out to express X-ray image quality by means of a meaningful and practically useful numerical system. Attenuations have been selected in such a manner that whole numbers of quality value figures ranging from -10 to +60 result in meaningful associations with radiological indications. Individual parameters are incorporated into the resulting values. A test body for determining information sensitivity figures is described that is practical easy built and inexpensive; its most important feature, however, is that it is reproducible and permits international comparisons. This test body provides a direct linking with the quality value figures.

  17. Aviation security x-ray detection challenges

    Science.gov (United States)

    Harvey, T.

    2016-05-01

    In this paper, a review of the background and some drivers are provided for X-ray screening for aviation security. Some of the key considerations are highlighted along with impacts of the image-based approaches and signature approaches. The role of information theory is discussed along with some recent work that may influence the technical direction by posing the question: "what measurements, parameters and metrics should be considered in future system design?" A path forward should be based on information theory, however electronic machines will likely interface with humans and be dollar-cost driven, so ultimately solutions must consider additional parameters other than only technical performance factors.

  18. X-Ray Exam: Scoliosis (For Parents)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Scoliosis KidsHealth > For Parents > X-Ray Exam: Scoliosis A A A What's in ... español Radiografía: escoliosis What It Is A scoliosis X-ray is a relatively safe and painless test ...

  19. X-Ray Exam: Neck (For Parents)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Neck KidsHealth > For Parents > X-Ray Exam: Neck A A A What's in ... español Radiografía: cuello What It Is A neck X-ray is a safe and painless test that ...

  20. X-Ray Exam: Femur (Upper Leg)

    Science.gov (United States)

    ... Old Feeding Your 1- to 2-Year-Old X-Ray Exam: Femur (Upper Leg) KidsHealth > For Parents > X-Ray Exam: Femur (Upper Leg) A A A ... español Radiografía: fémur What It Is A femur X-ray is a safe and painless test that ...

  1. Center for X-ray Optics, 1988

    Energy Technology Data Exchange (ETDEWEB)

    1989-04-01

    This report briefly reviews the following topics: soft-x-ray imaging; reflective optics for hard x-rays; coherent XUV sources; spectroscopy with x-rays; detectors for coronary artery imaging; synchrotron-radiation optics; and support for the advanced light source.

  2. Cryotomography x-ray microscopy state

    Science.gov (United States)

    Le Gros, Mark; Larabell, Carolyn A.

    2010-10-26

    An x-ray microscope stage enables alignment of a sample about a rotation axis to enable three dimensional tomographic imaging of the sample using an x-ray microscope. A heat exchanger assembly provides cooled gas to a sample during x-ray microscopic imaging.

  3. A proposal for a collecting mirror assembly for large divergence x-ray sources.

    Science.gov (United States)

    Ichimaru, Satoshi; Hatayama, Masatoshi; Ohchi, Tadayuki; Oku, Satoshi

    2014-11-01

    We propose a new type of collecting mirror assembly (CMA) for x rays, which will enable us to build a powerful optical system for collecting x rays from large divergence sources. The CMA consists of several mirror sections connected in series. The angle of each section is designed so that the x rays reflected from it are parallel to the x rays directly incident on the following sections. A simplified CMA structure is designed and applied to the Al-Kα emission line. It is estimated that by using the CMA the number of x rays detected could be increased by a factor of about 2.5.

  4. Moving-Article X-Ray Imaging System and Method for 3-D Image Generation

    Science.gov (United States)

    Fernandez, Kenneth R. (Inventor)

    2012-01-01

    An x-ray imaging system and method for a moving article are provided for an article moved along a linear direction of travel while the article is exposed to non-overlapping x-ray beams. A plurality of parallel linear sensor arrays are disposed in the x-ray beams after they pass through the article. More specifically, a first half of the plurality are disposed in a first of the x-ray beams while a second half of the plurality are disposed in a second of the x-ray beams. Each of the parallel linear sensor arrays is oriented perpendicular to the linear direction of travel. Each of the parallel linear sensor arrays in the first half is matched to a corresponding one of the parallel linear sensor arrays in the second half in terms of an angular position in the first of the x-ray beams and the second of the x-ray beams, respectively.

  5. Characterization of a free-air ionization chamber in direct X-ray beams as used in mammography; Caracterizacao de uma camara de ionizacao de ar-livre em feixes diretos de raios X utilizados em mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Mateus Hilario de

    2014-08-01

    At this work stability and characterization tests were undertaken on a Victoreen free-air ionization chamber, model 481. The tests were realized using direct X-ray beams as a contribution for its establishment as a primary standard system of the quantity air kerma. The characterization tests were: saturation curve, ion collection efficiency, polarity effect, response linearity with the air kerma rate and response linearity with the chamber volume variation. The ion collection efficiency allowed the determination of the ion recombination factor. Most of the test results showed agreement with the limits established by international standards. Furthermore, the air attenuation factors for the mammography beams with aluminum and molybdenum filters were obtained. The factors for photon transmission and scattering at the diaphragm edges were also determined for mammography beams with aluminum filter and for the standard beam with molybdenum filter. (author)

  6. Direct Evidence of the Symmetry Change of Co-3d Orbitals Associated with the Spin-State Transition in LaCoO3 by X-ray Compton Scattering

    Science.gov (United States)

    Kobayashi, Yoshihiko; Sakurai, Yoshiharu; Itou, Masayoshi; Sato, Keisuke; Asai, Kichizo

    2015-11-01

    We have investigated the electron momentum density of Co-3d electrons in LaCoO3 using X-ray Compton scattering in order to demonstrate the symmetry change of the Co(3d) electron orbital states through the spin-state transition. The electron momentum density reconstructed from the Compton profiles indicates the symmetry change in the 3d electron-orbital states between below and above 100 K, which provides the first microscopic direct evidence for the orbital symmetry change of occupied electronic state associated with the spin-state transition in LaCoO3. The reproduced electron orbital states show a covalent bond with O-2p orbitals, which is responsible for the collectiveness in the characteristics of the spin-state transition.

  7. The influence of methanol on the chemical state of PtRu anodes in a high-temperature direct methanol fuel cell studied in situ by synchrotron-based near-ambient pressure x-ray photoelectron spectroscopy

    Science.gov (United States)

    Saveleva, Viktoriia A.; Daletou, Maria K.; Savinova, Elena R.

    2017-01-01

    Synchrotron radiation-based near-ambient pressure x-ray photoelectron spectroscopy (NAP-XPS) has recently become a powerful tool for the investigation of interfacial phenomena in electrochemical power sources such as batteries and fuel cells. Here we present an in situ NAP-XPS study of the anode of a high-temperature direct methanol fuel cell with a phosphoric acid-doped hydrocarbon membrane, which reveals an enhanced flooding of the Pt3Ru anode with phosphoric acid in the presence of methanol. An analysis of the electrode surface composition depending on the cell voltage and on the presence of methanol reveals the strong influence of the latter on the extent of Pt oxidation and on the transformation of Ru into Ru (IV) hydroxide.

  8. Geometry calibration between X-ray source and detector for tomosynthesis with a portable X-ray system.

    Science.gov (United States)

    Sato, Kohei; Ohnishi, Takashi; Sekine, Masashi; Haneishi, Hideaki

    2017-05-01

    Tomosynthesis is attracting attention as a low-dose tomography technology compared with X-ray CT. However, conventional tomosynthesis imaging devices are large and stationary. Furthermore, there is a limitation in the working range of the X-ray source during image acquisition. We have previously proposed the use of a portable X-ray device for tomosynthesis that can be used for ward rounds and emergency medicine. The weight of this device can be reduced by using a flat panel detector (FPD), and flexibility is realized by the free placement of the X-ray source and FPD. Tomosynthesis using a portable X-ray device requires calibration of the geometry between the X-ray source and detector at each image acquisition. We propose a method for geometry calibration and demonstrate tomosynthesis image reconstruction by this method. An image processing-based calibration method using an asymmetric and multilayered calibration object (AMCO) is presented. Since the AMCO is always attached to the X-ray source housing for geometry calibration, the additional setting of a calibration object or marker around or on the patients is not required. The AMCO's multilayer structure improves the calibration accuracy, especially in the out-of-plane direction. Two experiments were conducted. The first was performed to evaluate the calibration accuracy using an XY positioning stage and a gonio stage. As a result, an accuracy of approximately 1 mm was achieved both in the in-plane and out-of-plane directions. An angular accuracy of approximately [Formula: see text] was confirmed. The second experiment was conducted to evaluate the reconstructed image using a foot model phantom. Only the sagittal plane could be clearly observed with the proposed method. We proposed a tomosynthesis imaging system using a portable X-ray device. From the experimental results, the proposed method could provide sufficient calibration accuracy and a clear sagittal plane of the reconstructed tomosynthesis image.

  9. 定向X射线检测系统检验辐射场的调校方法%Adjustment and Calibration Method of Inspection Radiation Field for Directional X-ray Inspection System

    Institute of Scientific and Technical Information of China (English)

    刘通; 边昭斌; 张圣光; 蒋太秋

    2015-01-01

    介绍了螺旋缝埋弧焊管检测用定向X射线检测系统检验辐射场的构成,以及实际检验中需要调整DR检测系统的机构,如探臂、射线管头、平板探测器等的调整。重点介绍了定向X射线检测系统检验辐射场的两种调校方法,即螺栓校准和辐射场校准器校准,分析了两种调校方法的优缺点。以自主设计的辐射场校准器调校方法为例,通过对φ325 mm×8 mm焊管进行辐射场差异模拟试验,得到了不正确调校辐射场对焊偏检验结果有一定影响的结论。%In this article, it briefly introduced the structure of inspection radiation field for directional X-ray inspection system used in SAWH pipe, and some organizations need to adjust DR inspection system, such as exploring arm, tube head, flat panel detector etc. It emphasized 2 adjustment and calibration methods for directional X-ray inspection system, the bolt calibration and radiation field calibrator, and analyzed advantages and disadvantages for the above two methods. Taking independent design radiation field calibrator calibration method as sample, through radiation field difference simulation test for φ325 mm ×8 mm welded pipe, it is concluded that incorrect calibration radiation field has certain influence on misalignment inspection result.

  10. Coherent methods in X-ray scattering

    Energy Technology Data Exchange (ETDEWEB)

    Gorobtsov, Oleg

    2017-05-15

    X-ray radiation has been used to study structural properties of materials for more than a hundred years. Construction of extremely coherent and bright X-ray radiation sources such as free electron lasers (FELs) and latest generationstorage rings led to rapid development of experimental methods relying on high radiation coherence. These methods allow to perform revolutionary studies in a wide range of fields from solid state physics to biology. In this thesis I focus on several important problems connected with the coherent methods. The first part considers applications of dynamical diffraction theory on crystals to studies with coherent X-ray radiation. It presents the design of a high-resolution spectrometer for free electron lasers that should allow to resolve spectral structure of individual FEL pulses. The spectrometer is based on the principle of dynamical diffraction focusing. The knowledge of individual FEL pulse spectra is necessary for understanding FEL longitudinal coherence. In the same part I present quasi-kinematical approximation to dynamical theory which allows to treat analytically phase effects observed in X-ray coherent imaging on nanocrystals. These effects may play a big role when methods such as ptychography are used to study crystalline samples. The second part deals with measurements of FEL coherence properties using intensity - intensity interferometry. Results of several experiments performed at FELs FLASH and LCLS are revealed in this section. I have developed models and theories to explain the behavior observed in experiments on FLASH. These models allowed to extract information about external positional jitter of FEL pulses and secondary beams present in FEL radiation. In the LCLS experiment the Hanbury Brown and Twiss type interferometry was performed on Bragg peaks from colloidal crystal. This did not require additional measurements without the sample and information was extracted directly from diffraction patterns. Therefore intensity

  11. X-Ray Visions of SS Cygni

    Science.gov (United States)

    Young, D. L.

    2004-12-01

    The Chandra X-Ray Observatory is the most sophisticated X-ray observatory launched by NASA. Chandra is designed to observe X-rays from highenergy regions of the universe, such as X-ray binary stars. On September 14, 2000, triggered by alerts from amateur astronomers worldwide, Chandra observed the outburst of the brightest northern dwarf nova SS Cygni. The cooperation of hundreds of amateur variable star astronomers and the Chandra X-Ray scientists and spacecraft specialists provided proof that the collaboration of amateur and professional astronomers is a powerful tool to study cosmic phenomena.

  12. X-ray Spectroscopy of Cooling Cluster

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, J.R.; /SLAC; Fabian, A.C.; /Cambridge U., Inst. of Astron.

    2006-01-17

    We review the X-ray spectra of the cores of clusters of galaxies. Recent high resolution X-ray spectroscopic observations have demonstrated a severe deficit of emission at the lowest X-ray temperatures as compared to that expected from simple radiative cooling models. The same observations have provided compelling evidence that the gas in the cores is cooling below half the maximum temperature. We review these results, discuss physical models of cooling clusters, and describe the X-ray instrumentation and analysis techniques used to make these observations. We discuss several viable mechanisms designed to cancel or distort the expected process of X-ray cluster cooling.

  13. Comets: mechanisms of x-ray activity

    Science.gov (United States)

    Ibadov, Subhon

    2016-07-01

    Basic mechanisms of X-ray activity of comets are considered, including D-D mechanism corresponding to generation of X-rays due to production of hot short-living plasma clumps at high-velocity collisions between cometary and interplanetary dust particles as well as M-M one corresponding to production of X-rays due to recombination of multicharge ions of solar wind plasma via charge exchange process at their collisions with molecules/atoms of the cometary atmospheres. Peculiarities of the variation of the comet X-ray spectrum and X-ray luminosity with variation of its heliocentric distance are revealed.

  14. The CZT X-ray Imager on AXO

    Science.gov (United States)

    Budtz-Jørgensen, C.; Kuvvetli, I.; Westergaard, N. J.; Jonasson, P.; Reglero, V.; Eyles, C.; Neubert, T.

    2001-03-01

    DSRI has initiated a development program of CZT X-ray and gamma ray detectors employing strip readout techniques. A dramatic improvement of the energy response was found operating the detectors as so-called drift detectors. For the electronic readout, modern ASIC chips were investigated. Modular design and the low power electronics will make large area detectors using the drift strip method feasible. The performance of a prototype CZT system will be presented and discussed. One such detector system has been proposed for future space missions: The X-Ray Imager (XRI) on the Atmospheric X-ray Observatory (AXO), which is a mission proposed to the Danish Small Satellite Program and is dedicated to observations of X-ray generating processes in the Earth's atmosphere. Of special interest will be simultaneous optical and X-ray observations of sprites that are flashes appearing directly above an active thunderstorm system. Additional objective is a detailed mapping of the auroral X-ray and optical emission. XRI comprises a coded mask and a 20 cm × 40 cm CZT detector array covering an energy range from 5 to 200 keV.

  15. X-rays from solar system objects

    CERN Document Server

    Bhardwaj, Anil; Gladstone, G Randall; Cravens, Thomas E; Lisse, Carey M; Dennerl, Konrad; Branduardi-Raymont, Graziella; Wargelin, Bradford J; Waite, J Hunter; Robertson, Ina; Ostgaard, Nikolai; Beiersdorfer, Peter; Snowden, Steven L; Kharchenko, Vasili; 10.1016/j.pss.2006.11.009

    2010-01-01

    During the last few years our knowledge about the X-ray emission from bodies within the solar system has significantly improved. Several new solar system objects are now known to shine in X-rays at energies below 2 keV. Apart from the Sun, the known X-ray emitters now include planets (Venus, Earth, Mars, Jupiter, and Saturn), planetary satellites (Moon, Io, Europa, and Ganymede), all active comets, the Io plasma torus (IPT), the rings of Saturn, the coronae (exospheres) of Earth and Mars, and the heliosphere. The advent of higher-resolution X-ray spectroscopy with the Chandra and XMM-Newton X-ray observatories has been of great benefit in advancing the field of planetary X-ray astronomy. Progress in modeling X-ray emission, laboratory studies of X-ray production, and theoretical calculations of cross-sections, have all contributed to our understanding of processes that produce X-rays from the solar system bodies. At Jupiter and Earth, both auroral and non-auroral disk X-ray emissions have been observed. X-ray...

  16. X-ray metrology and performance of a 45-cm long x-ray deformable mirror.

    Science.gov (United States)

    Poyneer, Lisa A; Brejnholt, Nicolai F; Hill, Randall; Jackson, Jessie; Hagler, Lisle; Celestre, Richard; Feng, Jun

    2016-05-01

    We describe experiments with a 45-cm long x-ray deformable mirror (XDM) that have been conducted in End Station 2, Beamline 5.3.1 at the Advanced Light Source. A detailed description of the hardware implementation is provided. We explain our one-dimensional Fresnel propagation code that correctly handles grazing incidence and includes a model of the XDM. This code is used to simulate and verify experimental results. Initial long trace profiler metrology of the XDM at 7.5 keV is presented. The ability to measure a large (150-nm amplitude) height change on the XDM is demonstrated. The results agree well with the simulated experiment at an error level of 1 μrad RMS. Direct imaging of the x-ray beam also shows the expected change in intensity profile at the detector.

  17. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Hatoyama, Saitama (Japan). Advanced Research Lab.

    1996-08-01

    X-ray transmission imaging that creates image contrast from the distribution of the X-ray absorption coefficient is not sensitive to materials consisting of light elements such as hydrogen, carbon, nitrogen, and oxygen. On the other hand, the X-ray phase shift caused by the light elements is substantial enough to be detected even when absorption is almost zero. Hence, phase-contrast X-ray imaging is a promising technique for observing the structure inside biological soft tissues without the need for staining and without serious radiation exposure. Using fringe scanning X-ray interferometry, the X-ray phase shift caused by an object was measured. Three-dimensional image reconstruction of cancerous tissues using the measured phase shifts was enabled under tomographic configuration phase-contrast X-ray computed tomography (CT). (author)

  18. A new method to calibrate the absolute sensitivity of a soft X-ray streak camera

    Science.gov (United States)

    Yu, Jian; Liu, Shenye; Li, Jin; Yang, Zhiwen; Chen, Ming; Guo, Luting; Yao, Li; Xiao, Shali

    2016-12-01

    In this paper, we introduce a new method to calibrate the absolute sensitivity of a soft X-ray streak camera (SXRSC). The calibrations are done in the static mode by using a small laser-produced X-ray source. A calibrated X-ray CCD is used as a secondary standard detector to monitor the X-ray source intensity. In addition, two sets of holographic flat-field grating spectrometers are chosen as the spectral discrimination systems of the SXRSC and the X-ray CCD. The absolute sensitivity of the SXRSC is obtained by comparing the signal counts of the SXRSC to the output counts of the X-ray CCD. Results show that the calibrated spectrum covers the range from 200 eV to 1040 eV. The change of the absolute sensitivity in the vicinity of the K-edge of the carbon can also be clearly seen. The experimental values agree with the calculated values to within 29% error. Compared with previous calibration methods, the proposed method has several advantages: a wide spectral range, high accuracy, and simple data processing. Our calibration results can be used to make quantitative X-ray flux measurements in laser fusion research.

  19. Full-field transmission x-ray imaging with confocal polycapillary x-ray optics.

    Science.gov (United States)

    Sun, Tianxi; Macdonald, C A

    2013-02-07

    A transmission x-ray imaging setup based on a confocal combination of a polycapillary focusing x-ray optic followed by a polycapillary collimating x-ray optic was designed and demonstrated to have good resolution, better than the unmagnified pixel size and unlimited by the x-ray tube spot size. This imaging setup has potential application in x-ray imaging for small samples, for example, for histology specimens.

  20. Cascaded-systems analysis of sandwich x-ray detectors

    Science.gov (United States)

    Kim, D. W.; Kim, J.; Yun, S.; Youn, H.; Kim, H. K.

    2016-12-01

    Active sandwich-like multilayer detectors have been developed, and their potential for motion-artifact-free dual-energy x-ray imaging at a single exposure has been demonstrated in the material decomposition context. Since the sandwich detector uses the x-ray beam transmittance through the front layer, direct x-ray interaction within photodiodes in the front layer is unavoidable, and which can increase noise in the front detector images. Similar direct x-ray interaction can also occur in the rear detector layer. To obtain a better contrast performance, an additional filter layer can be placed between the two detector layers. However, this filter layer can increase adversely noise in images obtained from the rear detector layer by reducing the number of x-ray photons reaching it. A theoretical model, which can describe the signal-to-noise performance of the sandwich detector as functions of various design parameters, has been developed by using a linear cascaded-systems theory. From the cascaded-systems analysis, the direct x-ray interaction increases noise at the high spatial frequencies where the number of secondary quanta lessens. The intermediate filter layer enhances the contribution of additive electronic noise in the overall noise performance of the rear detector layer. The detailed cascaded-systems analysis on the x-ray sandwich detectors are reported in comparisons with the measured noise-power spectra and detective quantum efficiencies. The developed model will be useful for a better design and practical use of a sandwich detector for single-shot dual-energy imaging.

  1. Editorial: Focus on X-ray Beams with High Coherence

    Science.gov (United States)

    Robinson, Ian; Gruebel, Gerhard; Mochrie, Simon

    2010-03-01

    /Pd multilayer films K A Seu, R Su, S Roy, D Parks, E Shipton, E E Fullerton and S D Kevan Holographic and diffractive x-ray imaging using waveguides as quasi-point sources K Giewekemeyer, H Neubauer, S Kalbfleisch, S P Krüger and T Salditt Mapping the conformations of biological assemblies P Schwander, R Fung, G N Phillips Jr and A Ourmazd Imaging the displacement field within epitaxial nanostructures by coherent diffraction: a feasibility study Ana Diaz, Virginie Chamard, Cristian Mocuta, Rogerio Magalhães-Paniago, Julian Stangl, Dina Carbone, Till H Metzger and Günther Bauer The potential for two-dimensional crystallography of membrane proteins at future x-ray free-electron laser sources Cameron M Kewish, Pierre Thibault, Oliver Bunk and Franz Pfeiffer Coherence properties of hard x-ray synchrotron sources and x-ray free-electron lasers I A Vartanyants and A Singer Coherent imaging of biological samples with femtosecond pulses at the free-electron laser FLASH A P Mancuso, Th Gorniak, F Staier, O M Yefanov, R Barth, C Christophis, B Reime, J Gulden, A Singer, M E Pettit, Th Nisius, Th Wilhein, C Gutt, G Grübel, N Guerassimova, R Treusch, J Feldhaus, S Eisebitt, E Weckert, M Grunze, A Rosenhahn and I A Vartanyants

  2. Imaging local electric fields produced upon synchrotron X-ray exposure.

    Science.gov (United States)

    Dettmar, Christopher M; Newman, Justin A; Toth, Scott J; Becker, Michael; Fischetti, Robert F; Simpson, Garth J

    2015-01-20

    Electron-hole separation following hard X-ray absorption during diffraction analysis of soft materials under cryogenic conditions produces substantial local electric fields visualizable by second harmonic generation (SHG) microscopy. Monte Carlo simulations of X-ray photoelectron trajectories suggest the formation of substantial local electric fields in the regions adjacent to those exposed to X-rays, indicating a possible electric-field-induced SHG (EFISH) mechanism for generating the observed signal. In studies of amorphous vitreous solvents, analysis of the SHG spatial profiles following X-ray microbeam exposure was consistent with an EFISH mechanism. Within protein crystals, exposure to 12-keV (1.033-Å) X-rays resulted in increased SHG in the region extending ∼ 3 μm beyond the borders of the X-ray beam. Moderate X-ray exposures typical of those used for crystal centering by raster scanning through an X-ray beam were sufficient to produce static electric fields easily detectable by SHG. The X-ray-induced SHG activity was observed with no measurable loss for longer than 2 wk while maintained under cryogenic conditions, but disappeared if annealed to room temperature for a few seconds. These results provide direct experimental observables capable of validating simulations of X-ray-induced damage within soft materials. In addition, X-ray-induced local fields may potentially impact diffraction resolution through localized piezoelectric distortions of the lattice.

  3. Off-axis holographic lens spectrum-splitting photovoltaic system for direct and diffuse solar energy conversion.

    Science.gov (United States)

    Vorndran, Shelby D; Chrysler, Benjamin; Wheelwright, Brian; Angel, Roger; Holman, Zachary; Kostuk, Raymond

    2016-09-20

    This paper describes a high-efficiency, spectrum-splitting photovoltaic module that uses an off-axis volume holographic lens to focus and disperse incident solar illumination to a rectangular shaped high-bandgap indium gallium phosphide cell surrounded by strips of silicon cells. The holographic lens design allows efficient collection of both direct and diffuse illumination to maximize energy yield. We modeled the volume diffraction characteristics using rigorous coupled-wave analysis, and simulated system performance using nonsequential ray tracing and PV cell data from the literature. Under AM 1.5 illumination conditions the simulated module obtained a 30.6% conversion efficiency. This efficiency is a 19.7% relative improvement compared to the more efficient cell in the system (silicon). The module was also simulated under a typical meteorological year of direct and diffuse irradiance in Tucson, Arizona, and Seattle, Washington. Compared to a flat panel silicon module, the holographic spectrum splitting module obtained a relative improvement in energy yield of 17.1% in Tucson and 14.0% in Seattle. An experimental proof-of-concept volume holographic lens was also fabricated in dichromated gelatin to verify the main characteristics of the system. The lens obtained an average first-order diffraction efficiency of 85.4% across the aperture at 532 nm.

  4. Hard x-ray imaging polarimeter for PolariS

    Science.gov (United States)

    Hayashida, Kiyoshi; Kim, Juyong; Sadamoto, Masaaki; Yoshinaga, Keigo; Gunji, Shuichi; Mihara, Tatehiro; Kishimoto, Yuji; Kubo, Hidetoshi; Mizuno, Tsunefumi; Takahashi, Hiromitsu; Dotani, Tadayasu; Yonetoku, Daisuke; Nakamori, Takeshi; Yoneyama, Tomokage; Ikeyama, Yuki; Kamitsukasa, Fumiyoshi

    2016-07-01

    Hard X-ray imaging polarimeters are developed for the X-ray γ-ray polaeimtery satellite PolariS. The imaging polarimter is scattering type, in which anisotropy in the direction of Compton scattering is employed to measure the hard X-ray (10-80 keV) polarization, and is installed on the focal planes of hard X-ray telescopes. We have updated the design of the model so as to cover larger solid angles of scattering direction. We also examine the event selection algorithm to optimize the detection efficiency of recoiled electrons in plastic scintillators. We succeed in improving the efficiency by factor of about 3-4 from the previous algorithm and criteria for 18-30 keV incidence. For 23 keV X-ray incidence, the recoiled electron energy is about 1 keV. We measured the efficiency to detect recoiled electrons in this case, and found about half of the theoretical limit. The improvement in this efficiency directly leads to that in the detection efficiency. In other words, however, there is still a room for improvement. We examine various process in the detector, and estimate the major loss is primarily that of scintillation light in a plastic scintillator pillar with a very small cross section (2.68mm squared) and a long length (40mm). Nevertheless, the current model provides the MDP of 6% for 10mCrab sources, which are the targets of PolariS.

  5. Mutual control of X-rays and nuclear transitions

    Energy Technology Data Exchange (ETDEWEB)

    Gunst, Jonas Friedrich

    2015-12-14

    In the course of this Thesis the mutual control between X-rays and nuclear transitions is investigated theoretically. In the first Part, we study the nuclear photoexcitation with the highly brilliant and coherent X-ray free-electron lasers (XFELs). Apart from amplifying the direct resonant interaction with nuclear transitions, the super-intense XFEL can produce new states of matter like cold, high-density plasmas where secondary nuclear excitation channels may come into play, e.g., nuclear excitation by electron capture (NEEC). Our results predict that in the case of {sup 57}Fe targets secondary NEEC can be safely neglected, whereas it is surprisingly the dominating contribution (in comparison to the direct photoexcitation) for the XFEL-induced {sup 93m}Mo isomer triggering. Based on these case studies, we elaborate a general set of criteria to identify the prevailing excitation channel for a certain nuclear isotope. These criteria may be most relevant for future nuclear resonance experiments at XFEL facilities. On the opposite frontier, the interplay between single X-ray photons and nuclear transitions offer potential storage and processing applications for information science in their most compact form. In the second Part of this Thesis, we show that nuclear forward scattering off {sup 57}Fe targets can be employed to process polarization-encoded single X-rays via timed magnetic field rotations. Apart from the realization of logical gates with X-rays, the polarization encoding is used to design an X-ray quantum eraser scheme where the interference between scattering paths can be switched off and on in a controlled manner. Such setups may advance time-energy complementarity tests to so far unexplored parameter regimes, e.g., to the domain of X-ray quanta.

  6. Controlling X-rays With Light

    Energy Technology Data Exchange (ETDEWEB)

    Glover, Ernie; Hertlein, Marcus; Southworth, Steve; Allison, Tom; van Tilborg, Jeroen; Kanter, Elliot; Krassig, B.; Varma, H.; Rude, Bruce; Santra, Robin; Belkacem, Ali; Young, Linda

    2010-08-02

    Ultrafast x-ray science is an exciting frontier that promises the visualization of electronic, atomic and molecular dynamics on atomic time and length scales. A largelyunexplored area of ultrafast x-ray science is the use of light to control how x-rays interact with matter. In order to extend control concepts established for long wavelengthprobes to the x-ray regime, the optical control field must drive a coherent electronic response on a timescale comparable to femtosecond core-hole lifetimes. An intense field is required to achieve this rapid response. Here an intense optical control pulse isobserved to efficiently modulate photoelectric absorption for x-rays and to create an ultrafast transparency window. We demonstrate an application of x-ray transparencyrelevant to ultrafast x-ray sources: an all-photonic temporal cross-correlation measurement of a femtosecond x-ray pulse. The ability to control x-ray/matterinteractions with light will create new opportunities at current and next-generation x-ray light sources.

  7. Direct imaging electron microscopy (EM) methods in modern structural biology: overview and comparison with X-ray crystallography and single-particle cryo-EM reconstruction in the studies of large macromolecules.

    Science.gov (United States)

    Miyaguchi, Katsuyuki

    2014-10-01

    Determining the structure of macromolecules is important for understanding their function. The fine structure of large macromolecules is currently studied primarily by X-ray crystallography and single-particle cryo-electron microscopy (EM) reconstruction. Before the development of these techniques, macromolecular structure was often examined by negative-staining, rotary-shadowing and freeze-etching EM, which are categorised here as 'direct imaging EM methods'. In this review, the results are summarised by each of the above techniques and compared with respect to four macromolecules: the ryanodine receptor, cadherin, rhodopsin and the ribosome-translocon complex (RTC). The results of structural analysis of the ryanodine receptor and cadherin are consistent between each technique. The results obtained for rhodopsin vary to some extent within each technique and between the different techniques. Finally, the results for RTC are inconsistent between direct imaging EM and other analytical techniques, especially with respect to the space within RTC, the reasons for which are discussed. Then, the role of direct imaging EM methods in modern structural biology is discussed. Direct imaging methods should support and verify the results obtained by other analytical methods capable of solving three-dimensional molecular architecture, and they should still be used as a primary tool for studying macromolecule structure in vivo.

  8. Effect of curve gro ove on the sp ectral resolution for soft X-ray holographic flat-field gratings%软X射线全息平焦场光栅的条纹弯曲现象及其对光谱分辨率的影响∗

    Institute of Scientific and Technical Information of China (English)

    陈火耀; 刘正坤; 王庆博; 易涛; 杨国洪; 洪义麟; 付绍军

    2014-01-01

    软X射线平焦场光栅光谱仪是等离子体诊断的重要仪器,其核心光学元件全息平焦场光栅通常采用非球面波记录光路制作,因此光栅条纹存在弯曲的现象.光栅条纹的弯曲会影响光谱成像质量,从而影响系统的光谱分辨率.记录光路的优化,只保证光栅子午面的线密度分布,因此优化的记录光路并不是惟一的,所以在保证子午面的线密度分布的同时能制作具有不同弯曲程度条纹的光栅.针对应用于0.8—6 nm的全息平焦场光栅,利用光线追迹方法分析了不同弯曲程度条纹光栅的光谱成像,发现采用柱面反射镜制作的接近于直条纹的光栅具有较好的光谱成像质量.相对于弯曲条纹的光栅,接近于直条纹的光栅理论光谱分辨率有明显的提高,入射波长为3 nm时,光谱分辨率从626提升到953,入射波长为5 nm时,光谱分辨率从635提高到1222.%The soft X-ray spectrograph is an important instrument for plasma diagnostics. As the core optical element of spectrograph, holographic flat-field grating is fabricated by aspheric wave-front recording optics, so grooves on the surface are curve. The curve grooves of the grating would affect the spectral image properties, thus influencing spectral resolutions. In the design of recording optics, only the groove density distribution on the surface in meridian line should be guaranteed, so optimized recording optics is not unique. Thus gratings with different curvatures of grooves but with expected groove density distribution could be obtained. For holographic flat-field gratings used in a 0.8–6 nm region, we analyze the influences of different curve grooves on the spectral image by ray tracing, and find that the almost straight grooves which are obtained by means of cylinder mirror can obtain the better spectral images. The theoretical results show that the spectral resolutions of grating with almost straight grooves are obviously improved compared

  9. Diffractive X-Ray Telescopes

    Science.gov (United States)

    Skinner, Gerald K.

    2010-01-01

    Diffractive X-ray telescopes, using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution many orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro-arc-seconds or even better, that would allow, for example, imaging of the distorted spacetime in the immediate vicinity of the super-massive black holes in the center of active galaxies. What then is precluding their immediate adoption? Extremely long focal lengths, very limited bandwidth, and difficulty stabilizing the image are the main problems. The history, and status of the development of such lenses is reviewed here and the prospects for managing the challenges that they present are discussed.

  10. Diffractive X-ray Telescopes

    CERN Document Server

    Skinner, Gerald K

    2010-01-01

    Diffractive X-ray telescopes using zone plates, phase Fresnel lenses, or related optical elements have the potential to provide astronomers with true imaging capability with resolution several orders of magnitude better than available in any other waveband. Lenses that would be relatively easy to fabricate could have an angular resolution of the order of micro-arc-seconds or even better, that would allow, for example, imaging of the distorted space- time in the immediate vicinity of the super-massive black holes in the center of active galaxies What then is precluding their immediate adoption? Extremely long focal lengths, very limited bandwidth, and difficulty stabilizing the image are the main problems. The history, and status of the development of such lenses is reviewed here and the prospects for managing the challenges that they present are discussed.

  11. Optimization of the quantitative direct solid total-reflection X-ray fluorescence analysis of glass microspheres functionalized with Zr organometallic compounds

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-Ruiz, Ramon, E-mail: ramon.fernandez@uam.e [Servicio Interdepartamental de Investigacion, Facultad de Ciencias, Universidad Autonoma de Madrid, Cantoblanco, E-28049, Madrid (Spain); Andres, Roman; Jesus, Ernesto de [Departamento de Quimica Inorganica, Universidad de Alcala, Campus Universitario, 28871, Alcala de Henares, Madrid (Spain); Terreros, Pilar [Instituto de Catalisis y Petroleo-Quimica, CSIC, Cantoblanco, 28049, Madrid (Spain)

    2010-06-15

    Quantitative determination of Zr in the system constituted by quartz microspheres functionalized with two kinds of organometallic compounds has been studied due to the importance of the correct quantization of the Zr from a catalytic point of view. Two parallel approximations were done, i.e. acid leaching and direct solid quantization. To validate the acid leaching TXRF measures, ICP-MS analysis were carried out. The results obtained by means of the optimization of the quantitative direct solid procedure show that, with a previous particle size distribution modification, TXRF obtain the same analytical results as ICP-MS and TXRF by acid leaching way but without previous chemical acid manipulation. This fact implies an important improvement for the analysis time, reagents costs and analysis facility and it proves again the versatility of TXRF to solve analytical problems in an easy, quick and accurate way. Additionally and for the direct solid TXRF measurements, a deeper study was done to evaluate the intrinsic analytical parameters of the Zr TXRF analysis of this material. So, the influence of the particle size distributions (modified by means of a high power ultrasound probe) with respect to uncertainty and detection limits for Zr were developed. The main analytical conclusion was the strong correlation between the average particle sizes and the TXRF analytical parameters of Zr measurements, i.e. concentration, accuracy, uncertainty and detection limits.

  12. Warm, Dense Plasma Characterization by X-ray Thomson Scattering

    Energy Technology Data Exchange (ETDEWEB)

    Landen, O L; Glenzer, S H; Cauble, R C; Lee, R W; Edwards, J E; Degroot, J S

    2000-07-18

    We describe how the powerful technique of spectrally resolved Thomson scattering can be extended to the x-ray regime, for direct measurements of the ionization state, density, temperature, and the microscopic behavior of dense cool plasmas. Such a direct measurement of microscopic parameters of solid density plasmas could eventually be used to properly interpret laboratory measurements of material properties such as thermal and electrical conductivity, EUS and opacity. In addition, x-ray Thomson scattering will provide new information on the characteristics of rarely and hitherto difficult to diagnose Fermi degenerate and strongly coupled plasmas.

  13. Amorphous silica studied by high energy x-ray diffraction

    DEFF Research Database (Denmark)

    Poulsen, H.F.; Neuefeind, J.; Neumann, H.B.

    1995-01-01

    The use of hard X-rays (60-300 keV) for diffraction studies of disordered materials has several advantages: higher resolution in direct space, smaller correction terms, removal of truncation effects, the possibility for operating in extreme environments and for direct comparison between X-ray.......3(3)degrees with a rms value of 4.2(3)degrees. For the Si-O-Si bond angle, several types of distribution V(alpha) = V-1(alpha) sin(alpha) were investigated. Best fits were obtained for rather broad distributions with V having its maximum at 147 degrees and V-1 at 180 degrees....

  14. High-resolution accelerator alignment using x-ray optics

    Directory of Open Access Journals (Sweden)

    Bingxin Yang

    2006-03-01

    Full Text Available We propose a novel alignment technique utilizing the x-ray beam of an undulator in conjunction with pinholes and position-sensitive detectors for positioning components of the accelerator, undulator, and beam line in an x-ray free-electron laser. Two retractable pinholes at each end of the undulator define a stable and reproducible x-ray beam axis (XBA. Targets are precisely positioned on the XBA using a pinhole camera technique. Position-sensitive detectors responding to both x-ray and electron beams enable direct transfer of the position setting from the XBA to the electron beam. This system has the potential to deliver superior alignment accuracy (1–3   μm for target pinholes in the transverse directions over a long distance (200 m or longer. It can be used to define the beam axis of the electron-beam–based alignment, enabling high reproducibility of the latter. This x-ray–based concept should complement the electron-beam–based alignment and the existing survey methods to raise the alignment accuracy of long accelerators to an unprecedented level. Further improvement of the transverse accuracy using x-ray zone plates will be discussed. We also propose a concurrent measurement scheme during accelerator operation to allow real-time feedback for transverse position correction.

  15. Handbook of X-Ray Data

    CERN Document Server

    Zschornack, Günter

    2007-01-01

    This sourcebook is intended as an X-ray data reference for scientists and engineers working in the field of energy or wavelength dispersive X-ray spectrometry and related fields of basic and applied research, technology, or process and quality controlling. In a concise and informative manner, the most important data connected with the emission of characteristic X-ray lines are tabulated for all elements up to Z = 95 (Americium). This includes X-ray energies, emission rates and widths as well as level characteristics such as binding energies, fluorescence yields, level widths and absorption edges. The tabulated data are characterized and, in most cases, evaluated. Furthermore, all important processes and phenomena connected with the production, emission and detection of characteristic X-rays are discussed. This reference book addresses all researchers and practitioners working with X-ray radiation and fills a gap in the available literature.

  16. Advances in nanomagnetism via X-ray techniques

    Energy Technology Data Exchange (ETDEWEB)

    Srajer, G. [Advanced Photon Source, Argonne National Laboratory, Argonne, IL 60439 (United States)]. E-mail: srajerg@aps.anl.gov; Lewis, L.H. [Center for Functional Nanomaterials, Brookhaven National Laboratory, Upton, NY 11973-5000 (United States); Bader, S.D. [Materials Science Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Epstein, A.J. [Department of Physics and Department of Chemistry, Ohio State University, Columbus, OH 43210 (United States); Fadley, C.S. [Department of Physics, University of California Davis, Davis, CA 95616 (United States); Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Fullerton, E.E. [San Jose Research Center, Hitachi Global Storage Technologies, San Jose, CA 95120 (United States); Hoffmann, A. [Materials Science Division, Argonne National Laboratory, Argonne, IL 60439 (United States); Kortright, J.B. [Materials Sciences Division, Lawrence Berkeley National Laboratory, Berkeley, CA 94720 (United States); Krishnan, Kannan M. [Department of Materials Science, University of Washington, Seattle, WA 98195 (United States); Majetich, S.A. [Physics Department, Carnegie Mellon University, Pittsburgh, PA 15213 (United States); Rahman, T.S. [Dept. of Physics, Carwell Hall, Kansas State University, Manhattan, KS 66506 (United States); Ross, C.A. [Dept. of Materials Science and Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139 (United States); Salamon, M.B. [Dept. of Physics, University of Illinois at Urbana-Champaign, 1110 W. Green Street, Urbana, IL 61801 (United States); Schuller, I.K. [Physics Department-0319, University of California-San Diego, La Jolla, CA 92093 (United States); Schulthess, T.C. [Center for Nanophase Materials Sciences, Oak Ridge National Laboratory, P. O. Box 2008, Oak Ridge, TN 37830-6164 (United States); Sun, J.Z. [IBM Research, 1101 Kitchawan Rd., Rt. 134, Yorktown Heights, NY 10598 (United States)

    2006-12-15

    This report examines the current status and the future directions of the field of nanomagnetism and assesses the ability of hard X-ray synchrotron facilities to provide new capabilities for making advances in this field. The report first identifies major research challenges that lie ahead in three broadly defined subfields of nanomagnetism: confined systems, clusters and complex oxides. It then examines the relevant experimental capabilities that are currently available at hard X-ray synchrotron light sources, using the Advanced Photon Source (APS) at Argonne as an example. Finally, recommendations are made for future development in X-ray facilities that will enhance the study of nanomagnetism, including new experimental directions, modifications that would enable in situ sample preparation, and measurements at high magnetic fields and/or low temperatures. In particular, in situ sample preparation is of high priority in many experiments, especially those in the area of surface magnetism.

  17. X-ray Optics for BES Light Source Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Dennis [Argonne National Lab. (ANL), Argonne, IL (United States); Padmore, Howard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lessner, Eliane [Dept. of Energy (DOE), Washington DC (United States). Office of Science

    2013-03-27

    potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today’s optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27–29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of

  18. X-ray Optics for BES Light Source Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Mills, Dennis [Argonne National Lab. (ANL), Argonne, IL (United States); Padmore, Howard [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Lessner, Eliane [Dept. of Energy (DOE), Washington DC (United States). Office of Science

    2013-03-27

    potentially revolutionary science involves soft excitations such as magnons and phonons; in general, these are well below the resolution that can be probed by today’s optical systems. The study of these low-energy excitations will only move forward if advances are made in high-resolution gratings for the soft X-ray energy region, and higher-resolution crystal analyzers for the hard X-ray region. In almost all the forefront areas of X-ray science today, the main limitation is our ability to focus, monochromate, and manipulate X-rays at the level required for these advanced measurements. To address these issues, the U.S. Department of Energy (DOE) Office of Basic Energy Sciences (BES) sponsored a workshop, X-ray Optics for BES Light Source Facilities, which was held March 27–29, 2013, near Washington, D.C. The workshop addressed a wide range of technical and organizational issues. Eleven working groups were formed in advance of the meeting and sought over several months to define the most pressing problems and emerging opportunities and to propose the best routes forward for a focused R&D program to solve these problems. The workshop participants identified eight principal research directions (PRDs), as follows: Development of advanced grating lithography and manufacturing for high-energy resolution techniques such as soft X-ray inelastic scattering. Development of higher-precision mirrors for brightness preservation through the use of advanced metrology in manufacturing, improvements in manufacturing techniques, and in mechanical mounting and cooling. Development of higher-accuracy optical metrology that can be used in manufacturing, verification, and testing of optomechanical systems, as well as at wavelength metrology that can be used for quantification of individual optics and alignment and testing of beamlines. Development of an integrated optical modeling and design framework that is designed and maintained specifically for X-ray optics. Development of

  19. Scanning electron microscopy (SEM) and X-ray dispersive spectrometry evaluation of direct laser metal sintering surface and human bone interface: a case series.

    Science.gov (United States)

    Mangano, Carlo; Piattelli, Adriano; Raspanti, Mario; Mangano, Francesco; Cassoni, Alessandra; Iezzi, Giovanna; Shibli, Jamil Awad

    2011-01-01

    Recent studies have shown that direct laser metal sintering (DLMS) produces structures with complex geometry and consequently that allow better osteoconductive properties. The aim of this patient report was to evaluate the early bone response to DLMS implant surface retrieved from human jaws. Four experimental DLMS implants were inserted in the posterior mandible of four patients during conventional dental implant surgery. After 8 weeks, the micro-implants and the surrounding tissue were removed and prepared for scanning electron microscopy (SEM) and histomorphometric analysis to evaluate the bone-implant interface. The SEM and EDX evaluations showed a newly formed tissue composed of calcium and phosphorus. The bone-to-implant contact presented a mean of 60.5 ± 11.6%. Within the limits of this patient report, data suggest that the DLMS surfaces presented a close contact with the human bone after a healing period of 8 weeks.

  20. X-Ray Eclipses of Active Galactic Nuclei

    Science.gov (United States)

    Zhang, Fupeng; Yu, Qingjuan; Lu, Youjun

    2017-08-01

    X-ray variation is a ubiquitous feature of active galactic nuclei (AGNs); however, its origin is not well understood. In this paper, we show that the X-ray flux variations in some AGNs, and correspondingly, the power spectral densities (PSDs) of the variations, may be interpreted as being caused by absorptions of eclipsing clouds or clumps in the broad-line region (BLR) and the dusty torus. By performing Monte Carlo simulations for a number of plausible cloud models, we systematically investigate the statistics of the X-ray variations resulting from the cloud eclipsing and the PSDs of the variations. For these models, we show that the number of eclipsing events can be significant and the absorption column densities due to those eclipsing clouds can be in the range from 1021 to {10}24 {{cm}}-2, leading to significant X-ray variations. We find that the PSDs obtained from the mock observations for the X-ray flux and the absorption column density resulting from these models can be described by a broken double power law, similar to those directly measured from observations of some AGNs. The shape of the PSDs depend strongly on the kinematic structures and the intrinsic properties of the clouds in AGNs. We demonstrate that the X-ray eclipsing model can naturally lead to a strong correlation between the break frequencies (and correspondingly the break timescales) of the PSDs and the masses of the massive black holes (MBHs) in the model AGNs, which can be well consistent with the one obtained from observations. Future studies of the PSDs of the AGN X-ray (and possibly also the optical-UV) flux and column density variations may provide a powerful tool to constrain the structure of the BLR and the torus and to estimate the MBH masses in AGNs.

  1. Development of a flat-panel X-ray source

    Science.gov (United States)

    Grant, Edwin Joseph

    A novel flat-panel transmission type X-ray source was developed for both medical and industrial use. Depending on the geometry of the given situation, the flat-panel X-ray source could be used in tomography, radiography or tomosynthesis. Furthermore, the unit could be used as a portable X-ray scanner or an integral part of an existing detection system. The design incorporates a field emission cathode made of ultra-nanocrystalline diamonds (UNCD) doped with nitrogen. These field emitters show good electron output at low power and can be deposited over large areas as is the case with carbon nanotube "forest" (CNT) cathodes. This work presents the first generation of the UNCD based FEA prototype which was manufactured at the Center of Nanoscale Material, within Argonne National Laboratory, with standard microfabrication techniques. The prototype is a 3 x 3 pixel field emission array (FEA), with a pixel size of 225 mum by 225 mum and a pitch of 500 mum. The fabricated cathode was developed using a microfabrication process which allows for individual electrically addressable UNCD gated arrays on-chip which demonstrated monolithic integration of the electron extraction grid. The transmission target consists of tungsten for X-ray generation, which is sputtered directly upon a thin aluminum sheet as an X-ray filter. A low voltage power supply allows for electron extraction between the cathode and the grid; while a high voltage power supply accelerates the electrons towards the anode. A low energy X-ray high purity germanium detector (HPGe) is mounted outside of the vacuum chamber for X-ray detection and measurement.

  2. X-ray data booklet. Revision

    Energy Technology Data Exchange (ETDEWEB)

    Vaughan, D. (ed.)

    1986-04-01

    A compilation of data is presented. Included are properties of the elements, electron binding energies, characteristic x-ray energies, fluorescence yields for K and L shells, Auger energies, energy levels for hydrogen-, helium-, and neonlike ions, scattering factors and mass absorption coefficients, and transmission bands of selected filters. Also included are selected reprints on scattering processes, x-ray sources, optics, x-ray detectors, and synchrotron radiation facilities. (WRF)

  3. X-ray generation using carbon nanotubes

    OpenAIRE

    Parmee, Richard J.; Collins, Clare M.; William I. Milne; Cole, Matthew T.

    2015-01-01

    This is the final published version. It first appeared at http://www.nanoconvergencejournal.com/content/2/1/1. Since the discovery of X-rays over a century ago the techniques applied to the engineering of X-ray sources have remained relatively unchanged. From the inception of thermionic electron sources, which, due to simplicity of fabrication, remain central to almost all X-ray applications, there have been few fundamental technological advances. However, with the emergence of ever more d...

  4. Applications of soft x-ray lasers

    Energy Technology Data Exchange (ETDEWEB)

    Skinner, C.H.

    1993-08-01

    The high brightness and short pulse duration of soft x-ray lasers provide unique advantages for novel applications. Imaging of biological specimens using x-ray lasers has been demonstrated by several groups. Other applications to fields such as chemistry, material science, plasma diagnostics, and lithography are beginning to emerge. We review the current status of soft x-ray lasers from the perspective of applications, and present an overview of the applications currently being developed.

  5. Phase-contrast X-ray CT

    Energy Technology Data Exchange (ETDEWEB)

    Momose, Atsushi [Hitachi Ltd., Saitama (Japan). Advanced Research Laboratory; Takeda, Tohoru; Itai, Yuji

    1995-12-01

    Phase-contrast X-ray computed tomography (CT) enabling the observation of biological soft tissues without contrast enhancement has been developed. The X-ray phase shift caused by an object is measured and input to a standard CT reconstruction algorithm. A thousand times increase in the image sensitivity to soft tissues is achieved compared with the conventional CT using absorption contrast. This is because the X-ray phase shift cross section of light elements is about a thousand times larger than the absorption cross section. The phase shift is detected using an X-ray interferometer and computer analyses of interference patterns. Experiments were performed using a synchrotron X-ray source. Excellent image sensitivity is demonstrated in the observation of cancerous rabbit liver. The CT images distinguish cancer lesion from normal liver tissue and, moreover, visualize the pathological condition in the lesion. Although the X-ray energy employed and the present observation area size are not suitable for medical applications as they are, phase-contrast X-ray CT is promising for investigating the internal structure of soft tissue which is almost transparent for X-rays. The high sensitivity also provides the advantage of reducing X-ray doses. (author).

  6. An Imaging X-Ray Polarimetry Mission

    Science.gov (United States)

    Weisskopf, Martin C.; Bellazini, Ronaldo; Costa, Enrico; Ramsey, Brian; O'Dell, Steve; Elsner, Ronald; Pavlov, George; Matt, Giorgio; Kaspi, Victoria; Tennant, Allyn; Coppi, Paolo; Wu, Kinwah; Siegmund, Oswald

    2008-01-01

    Technical progress both in x-ray optics and in polarization-sensitive x-ray detectors, which our groups have pioneered, enables a scientifically powerful---yet inexpensive---dedicated mission for imaging x-ray polarimetry. Such a mission is sufficiently sensitive to measure x-ray (linear) polarization for a broad range of cosmic sources --particularly those involving neutron stars, stellar black holes, and supermassive black holes (active galactic nuclei). We describe the technical elements, discuss a mission concept, and synopsize the important physical and astrophysical questions such a mission would address.

  7. The efficacy of x-ray pelvimetry

    Energy Technology Data Exchange (ETDEWEB)

    Barton, J.J. (Univ. of Illinois, Chicago); Garbaciak, J.A. Jr.; Ryan, G.M., Jr.

    1982-06-01

    Comparison is made of x-ray pelvimetry use on a public and private service in 1974 with experience in 1979, when the clinic service did no x-ray pelvimetry while the private service continued as before. It is concluded that the use of x-ray pelvimetry is inadequate as a predictor of cesarean section because of cephalopelvic disproportion, does not improve neonatal mortality, and poses potential hazards to the mother and fetus. Its use in the management of breech presentations is not currently established by our data. Guidelines are presented for the management of patients in labor without using x-ray pelvimetry.

  8. Symbiotic Stars in X-rays

    Science.gov (United States)

    Luna, G. J. M.; Sokoloski, J. L.; Mukai, K.; Nelson, T.

    2014-01-01

    Until recently, symbiotic binary systems in which a white dwarf accretes from a red giant were thought to be mainly a soft X-ray population. Here we describe the detection with the X-ray Telescope (XRT) on the Swift satellite of 9 white dwarf symbiotics that were not previously known to be X-ray sources and one that was previously detected as a supersoft X-ray source. The 9 new X-ray detections were the result of a survey of 41 symbiotic stars, and they increase the number of symbiotic stars known to be X-ray sources by approximately 30%. Swift/XRT detected all of the new X-ray sources at energies greater than 2 keV. Their X-ray spectra are consistent with thermal emission and fall naturally into three distinct groups. The first group contains those sources with a single, highly absorbed hard component, which we identify as probably coming from an accretion-disk boundary layer. The second group is composed of those sources with a single, soft X-ray spectral component, which likely arises in a region where low-velocity shocks produce X-ray emission, i.e. a colliding-wind region. The third group consists of those sources with both hard and soft X-ray spectral components. We also find that unlike in the optical, where rapid, stochastic brightness variations from the accretion disk typically are not seen, detectable UV flickering is a common property of symbiotic stars. Supporting our physical interpretation of the two X-ray spectral components, simultaneous Swift UV photometry shows that symbiotic stars with harder X-ray emission tend to have stronger UV flickering, which is usually associated with accretion through a disk. To place these new observations in the context of previous work on X-ray emission from symbiotic stars, we modified and extended the alpha/beta/gamma classification scheme for symbiotic-star X-ray spectra that was introduced by Muerset et al. based upon observations with the ROSAT satellite, to include a new sigma classification for sources with

  9. Hard X-ray Modulation Telescope

    Institute of Scientific and Technical Information of China (English)

    LU Fangjun

    2011-01-01

    The Hard X-ray Modulation Telescope (HXMT) will be China's first astronomical satellite. On board HXMT there are three kinds of slat-collimated telescopes, the High Energy X-ray Telescope (HE, 20-250 keV, 5000 cm^2), the Medium Energy X-ray Telescope (ME, 5-30 keV, 952 cm^2), and the Low Energy X-ray Telescope (LE, 1-15 keV, 384 cm^2).

  10. An Imaging X-Ray Polarimetry Mission

    Science.gov (United States)

    Weisskopf, Martin C.; Bellazini, Ronaldo; Costa, Enrico; Ramsey, Brian; O'Dell, Steve; Elsner, Ronald; Pavlov, George; Matt, Giorgio; Kaspi, Victoria; Tennant, Allyn; hide

    2008-01-01

    Technical progress both in x-ray optics and in polarization-sensitive x-ray detectors, which our groups have pioneered, enables a scientifically powerful---yet inexpensive---dedicated mission for imaging x-ray polarimetry. Such a mission is sufficiently sensitive to measure x-ray (linear) polarization for a broad range of cosmic sources --particularly those involving neutron stars, stellar black holes, and supermassive black holes (active galactic nuclei). We describe the technical elements, discuss a mission concept, and synopsize the important physical and astrophysical questions such a mission would address.

  11. X-rays from the youngest stars

    Science.gov (United States)

    Feigelson, Eric D.

    1994-01-01

    The X-ray properties of classical and weak-lined T Tauri stars are briefly reviewed, emphasizing recent results from the ROSAT satellite and prospects for ASCA. The interpretation of the high level of T Tauri X-rays as enhanced solar-type magnetic activity is discussed and criticized. The census of X-ray emitters is significantly increasing estimates of galactic star formation efficiency, and X-ray emission may be important for self-regulation of star formation. ASCA images will detect star formation regions out to several kiloparsecs and will study the magnetically heated plasma around T Tauri stars. However, images will often suffer from crowding effects.

  12. X-ray emission from comets.

    Science.gov (United States)

    Cravens, T E

    2002-05-10

    The discovery of x-ray emission from comet Hyakutake was surprising given that comets are known to be cold. Observations by x-ray satellites such as the Röntgen Satellite (ROSAT) indicate that x-rays are produced by almost all comets. Theoretical and observational work has demonstrated that charge-exchange collisions of highly charged solar wind ions with cometary neutral species can explain this emission. X-ray observations of comets and other solar system objects may be used to determine the structure and dynamics of the solar wind.

  13. X-ray pulsar rush in 1998

    Energy Technology Data Exchange (ETDEWEB)

    Imanishi, K.; Tsujimoto, K.; Nishiuchi, Mamiko; Yokogawa, J.; Koyama, K. [Kyoto Univ., Faculty of Science, Kyoto (Japan)

    1999-08-01

    We present recent remarkable topics about discoveries of X-ray pulsars. 1. Pulsations from two Soft Gamma-ray Repeaters: These pulsars have enormously strong magnetic field (B {approx} 10{sup 15} G), thus these are called as 'magnetar', new type of X-ray pulsars. 2. New Crab-like pulsars: These discoveries lead to suggesting universality of Crab-like pulsars. 3. An X-ray bursting millisecond pulsar: This is strong evidence for the recycle theory of generating radio millisecond pulsars. 4. X-ray pulsar rush in the SMC: This indicates the younger star formation history in the SMC. (author)

  14. Dominating IgE-binding epitope of Bet v 1, the major allergen of birch pollen, characterized by X-ray crystallography and site-directed mutagenesis.

    Science.gov (United States)

    Spangfort, Michael D; Mirza, Osman; Ipsen, Henrik; Van Neerven, R J Joost; Gajhede, Michael; Larsen, Jørgen N

    2003-09-15

    Specific allergy vaccination is an efficient treatment for allergic disease; however, the development of safer vaccines would enable a more general use of the treatment. Determination of molecular structures of allergens and allergen-Ab complexes facilitates epitope mapping and enables a rational approach to the engineering of allergen molecules with reduced IgE binding. In this study, we describe the identification and modification of a human IgE-binding epitope based on the crystal structure of Bet v 1 in complex with the BV16 Fab' fragment. The epitope occupies approximately 10% of the molecular surface area of Bet v 1 and is clearly conformational. A synthetic peptide representing a sequential motif in the epitope (11 of 16 residues) did not inhibit the binding of mAb BV16 to Bet v 1, illustrating limitations in the use of peptides for B cell epitope characterization. The single amino acid substitution, Glu(45)-Ser, was introduced in the epitope and completely abolished the binding of mAb BV16 to the Bet v 1 mutant within a concentration range 1000-fold higher than wild type. The mutant also showed up to 50% reduction in the binding of human polyclonal IgE, demonstrating that glutamic acid 45 is a critical amino acid also in a major human IgE-binding epitope. By solving the three-dimensional crystal structure of the Bet v 1 Glu(45)-Ser mutant, it was shown that the change in immunochemical activity is directly related to the Glu(45)-Ser substitution and not to long-range structural alterations or collapse of the Bet v 1 mutant tertiary structure.

  15. Reconstruction method for x-ray imaging capsule

    Science.gov (United States)

    Rubin, Daniel; Lifshitz, Ronen; Bar-Ilan, Omer; Weiss, Noam; Shapiro, Yoel; Kimchy, Yoav

    2017-03-01

    A colon imaging capsule has been developed by Check-Cap Ltd (C-Scan® Cap). For the procedure, the patient swallows a small amount of standard iodinated contrast agent. To create images, three rotating X-ray beams are emitted towards the colon wall. Part of the X-ray photons are backscattered from the contrast medium and the colon. These photons are collected by an omnidirectional array of energy discriminating photon counting detectors (CdTe/CZT) within the capsule. X-ray fluorescence (XRF) and Compton backscattering photons pertain different energies and are counted separately by the detection electronics. The current work examines a new statistical approach for the algorithm that reconstructs the lining of the colon wall from the X-ray detector readings. The algorithm performs numerical optimization for finding the solution to the inverse problem applied to a physical forward model, reflecting the behavior of the system. The forward model that was employed, accounts for the following major factors: the two mechanisms of dependence between the distance to the colon wall and the number photons, directional scatter distributions, and relative orientations between beams and detectors. A calibration procedure has been put in place to adjust the coefficients of the forward model for the specific capsule geometry, radiation source characteristics, and the detector response. The performance of the algorithm was examined in phantom experiments and demonstrated high correlation between actual phantom shape and x-ray image reconstruction. Evaluation is underway to assess the algorithm performance in clinical setting.

  16. Probing magnetar magnetosphere through X-ray polarization measurements

    Science.gov (United States)

    Taverna, R.; Muleri, F.; Turolla, R.; Soffitta, P.; Fabiani, S.; Nobili, L.

    2014-02-01

    The study of magnetars is of particular relevance since these objects are the only laboratories where the physics in ultra-strong magnetic fields can be directly tested. Until now, spectroscopic and timing measurements at X-ray energies in soft gamma repeaters and anomalous X-ray pulsars (AXPs) have been the main source of information about the physical properties of a magnetar and of its magnetosphere. Spectral fitting in the ˜0.5-10 keV range allowed us to validate the `twisted magnetosphere' model, probing the structure of the external field and estimating the density and velocity of the magnetospheric currents. Spectroscopy alone, however, may fail in disambiguating the two key parameters governing magnetospheric scattering (the charge velocity and the twist angle) and is quite insensitive to the source geometry. X-ray polarimetry, on the other hand, can provide a quantum leap in the field by adding two extra observables, the linear polarization degree and the polarization angle. Using the bright AXP 1RXS J170849.0-400910 as a template, we show that phase-resolved polarimetric measurements can unambiguously determine the model parameters, even with a small X-ray polarimetry mission carrying modern photoelectric detectors and existing X-ray optics. We also show that polarimetric measurements can pinpoint vacuum polarization effects and thus provide indirect evidence for ultra-strong magnetic fields.

  17. X-ray Measurements of Laser Irradiated Foam Filled Liners

    Science.gov (United States)

    Patankar, Siddharth; Mariscal, Derek; Goyon, Clement; Baker, Kevin; MacLaren, Stephan; Hammer, Jim; Baumann, Ted; Amendt, Peter; Menapace, Joseph; Berger, Bob; Afeyan, Bedros; Tabak, Max; Dixit, Sham; Kim, Sung Ho; Moody, John; Jones, Ogden

    2016-10-01

    Low-density foam liners are being investigated as sources of efficient x-rays. Understanding the laser-foam interaction is key to modeling and optimizing foam composition and density for x-ray production with reduced backscatter. We report on the experimental results of laser-irradiated foam liners filled with SiO2 and Ta2O5 foams at densities between 2 to 30mg/cc. The foam liners consist of polyimide tubes filled with low-density foams and sealed with a gold foil at one end. The open end of the tube is driven with 250J of 527nm laser light in a 2ns 2-step pulse using the Jupiter Laser Facility at LLNL. A full aperture backscatter system is used to diagnose the coupled energy and losses. A streaked x-ray camera and filtered x-ray pinhole cameras are used to measure laser penetration into the low-density foam for different mass densities. A HOPG crystal spectrometer is used to estimate a thermal electron temperature. Comparisons with beam propagation and x-ray emission simulations are presented. This work was performed under the auspices of the U.S. Department of Energy by the Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344, with funding support from the Laboratory Directed Research and Development Program under project 15.

  18. X-ray crystallography facility for the international space station

    Science.gov (United States)

    McDdonald, William T.; Lewis, Johanna L.; Smith, Craig D.; Delucas, Lawrence J.

    1997-01-01

    Directed by NASA's Office of Space Access and Technology (OSAT), the University of Alabama at Birmingham (UAB) Center for Macromolecular Crystallography (CMC) recently completed a Design Feasibility Study for the X-ray Crystallography Facility (XCF) for the International Space Station (ISS). The XCF is a facility for growing macromolecular protein crystals; harvesting, selecting, and mounting sample crystals, and snap-freezing the samples, if necessary; performing x-ray diffraction; and downlinking the diffraction data to the ground. Knowledge of the structure of protein molecules is essential for the development of pharmaceuticals by structure-based drug design techniques. Currently, x-ray diffraction of high quality protein crystals is the only method of determining the structure of these macromolecules. High quality protein crystals have been grown in microgravity onboard the Space Shuttle Orbiter for more than 10 years, but these crystals always have been returned to Earth for x-ray diffraction. The XCF will allow crystal growth, harvesting, mounting, and x-ray diffraction onboard the ISS, maximizing diffraction data quality and timeliness. This paper presents the XCF design concept, describing key feasibility issues for the ISS application and advanced technologies and operational features which resolve those issues. The conclusion is that the XCF design is feasible and can be operational onboard the ISS by early in 2002.

  19. Quality control for X-ray dosimetry with Fricke dosimeter

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Vivianne Lucia Bormann de [Centro Regional de Cincias Nucleares (CRCN-NE/CNEN-PE), Recife, PE (Brazil)]. E-mail: lsouza@cnen.gov.br; Austerlitz, C. [East Carolina University, NC (United States)]. E-mail: camposc@ecu.edu

    2007-07-01

    It is a well-established fact that the success of radiation therapy is dependent on the accurate dosimetry of the radiation beam used. This dosimetry must include equipment performance as well. A system for Fricke dosimetry was used for this purpose. The Fricke solution and a parallel ionization chamber (used for comparison) were irradiated with an X-ray beam from a Pantak X-ray equipment. The ionization chamber was positioned at a distance of 500 mm of the focal point, in the central axis of the X-ray field which is defined as 100x100 mm{sup 2} at the calibration distance. A plexiglas phantom appropriate to hold the polypropylene tube was used to irradiate the vials with the Fricke solution. The irradiated solutions were transferred directly from the polypropylene vials to 10 mm length cuvettes and the optical densities were measured in 304 nm using a Beckman Counter Model DU 640 spectrophotometer. Three institutions were visited to verify their procedures and two were in accordance with the lAEA recommended procedures for soft X-ray dosimetry. The results of the measurements performed in the institutions visited show that the Fricke dosimeter system developed can be used for quality control for soft X-ray equipment. (author)

  20. Optical Shaping of X-Ray Free-Electron Lasers

    Science.gov (United States)

    Marinelli, A.; Coffee, R.; Vetter, S.; Hering, P.; West, G. N.; Gilevich, S.; Lutman, A. A.; Li, S.; Maxwell, T.; Galayda, J.; Fry, A.; Huang, Z.

    2016-06-01

    In this Letter we report the experimental demonstration of a new temporal shaping technique for x-ray free-electron lasers (FELs). This technique is based on the use of a spectrally shaped infrared (IR) laser and allows optical control of the x-ray generation process. By accurately manipulating the spectral amplitude and phase of the IR laser, we can selectively modify the electron bunch longitudinal emittance thus controlling the duration of the resulting x-ray pulse down to the femtosecond time scale. Unlike other methods currently in use, optical shaping is directly applicable to the next generation of high-average power x-ray FELs such as the Linac Coherent Light Source-II or the European X-FEL, and it enables pulse shaping of FELs at the highest repetition rates. Furthermore, this laser-shaping technique paves the way for flexible tailoring of complex multicolor FEL pulse patterns required for nonlinear multidimensional x-ray spectroscopy as well as novel multicolor diffraction imaging schemes.

  1. X-ray linear dichroism dependence on ferroelectric polarization.

    Science.gov (United States)

    Polisetty, S; Zhou, J; Karthik, J; Damodaran, A R; Chen, D; Scholl, A; Martin, L W; Holcomb, M

    2012-06-20

    X-ray absorption spectroscopy and photoemission electron microscopy are techniques commonly used to determine the magnetic properties of thin films, crystals, and heterostructures. Recently, these methods have been used in the study of magnetoelectrics and multiferroics. The analysis of such materials has been compromised by the presence of multiple order parameters and the lack of information on how to separate these coupled properties. In this work, we shed light on the manifestation of dichroism from ferroelectric polarization and atomic structure using photoemission electron microscopy and x-ray absorption spectroscopy. Linear dichroism arising from the ferroelectric order in the PbZr0:2Ti0:8O3 thin films was studied as a function of incident x-ray polarization and geometry to unambiguously determine the angular dependence of the ferroelectric contribution to the dichroism. These measurements allow us to examine the contribution of surface charges and ferroelectric polarization as potential mechanisms for linear dichroism. The x-ray linear dichroism from ferroelectric order revealed an angular dependence based on the angle between the ferroelectric polarization direction and the x-ray polarization axis, allowing a formula for linear dichroism in ferroelectric samples to be defined.

  2. Optical, x-ray and microwave diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Tudisco, S.; Mascali, D.; Altana, C.; Anzalone, A.; Gammino, S.; Musumarra, A.; Musumeci, F.; Scordino, A. [INFN-LNS Via S. Sofia 62, 95123 Catania (Italy); Romano, F. P. [INFN-LNS Via S. Sofia 62, 95123 Catania (Italy); IBAM-CNR, Via Biblioteca 4, 95100 Catania (Italy); Tramontana, A. [INFN-LNS Via S. Sofia 62, 95123 Catania (Italy); Università di Catania, Dipartimento di Fisica e Astronomia, Via S. Sofia 64, Catania (Italy)

    2013-07-26

    Laser-driven ion acceleration is a new approach for the particles acceleration, which allows obtaining ion beams with unique properties, such as short burst duration, large particle number, small size source size, low transverse emittance. Currently, two main acceleration mechanisms have been identified and investigated: target normal sheath acceleration (TNSA) and radiation pressure acceleration (RPA). Electrons dynamics and energies are strongly coupled to these acceleration mechanisms and they can be investigated with optical and X-ray techniques. The main aim of these studies are the identification of few physical observables that can be directly correlated to the proton emission obtained (in terms of reproducibility and intensity) in operations with different target material and structure and laser-target interaction parameters.

  3. EXTraS discovery of two pulsators in the direction of the LMC: a Be/X-ray binary pulsar in the LMC and a candidate double-degenerate polar in the foreground

    CERN Document Server

    Haberl, F; Castillo, G A Rodriguez; Vasilopoulos, G; Delvaux, C; De Luca, A; Carpano, S; Esposito, P; Novara, G; Salvaterra, R; Tiengo, A; D'Agostino, D; Udalski, A

    2016-01-01

    The EXTraS project to explore the X-ray Transient and variable Sky searches for coherent signals in the X-ray archival data of XMM-Newton. XMM-Newton performed more than 400 pointed observations in the region of the Large Magellanic Cloud (LMC). We inspected the results of the EXTraS period search to systematically look for new X-ray pulsators in our neighbour galaxy. We analysed the XMM-Newton observations of two sources from the 3XMM catalogue which show significant signals for coherent pulsations. 3XMM J051259.8-682640 was detected as source with hard X-ray spectrum in two XMM-Newton observations, revealing a periodic modulation of the X-ray flux with 956~s. As optical counterpart we identify an early-type star with Halpha emission. The OGLE I-band light curve exhibits a regular pattern with three brightness dips which mark a period of ~1350 d. The X-ray spectrum of 3XMM J051034.7-670356 is dominated by a super-soft blackbody-like emission component (kT ~ 70 eV) which is modulated by nearly 100% with a per...

  4. Ultrafast Time Resolved X-ray Diffraction Studies of Laser Heated Metals and Semiconductors

    Science.gov (United States)

    Chen, Peilin; Tomov, I. V.; Rentzepis, P. M.

    1998-03-01

    Time resolved hard x-ray diffraction has been employed to study the dynamics of lattice structure deformation. When laser pulse energy is deposited in a material it generates a non uniform transient temperature distribution, which alters the lattice structure of the crystal. The deformed crystal lattice will change the angle of diffraction for a monochromatic x-ray beam. We report picosecond and nanosecond time resolved x-ray diffraction measurements of the lattice temperature distribution, transient structure and stress, in Pt (111) and GaAs (111) crystals, caused by pulsed UV laser irradiation. An ArF excimer laser operated at 300 Hz was used, both, to drive an x-ray diode with copper anode and heat the crystal. Bragg diffracted x-ray radiation was recorded by a direct imaging x-ray CCD. Changes in the diffraction patterns induced by a few millijouls pulse energy were observed at different time delays between the laser heating pulse and the x-ray probing pulse. A kinematical model for time resolved x-ray diffraction was used to analyze the experimental data. Good agreement between the measured and calculated scattered x-ray intensities profiles was achieved, indicating that detailed time resolved x-ray diffraction measurements can be made with nanosecond and picosecond resolution for small temperature changes. Our system can detect changes in the lattice spacing of about 10-3 A.

  5. Muonic X-ray spectroscopy: Effect of the presence of protons on X-ray production

    National Research Council Canada - National Science Library

    Mohamadsalehi, F; Gheisari, R; Rahimi, N

    2016-01-01

    ... . The target has a high efficiency for analyzing characteristic X-rays in ion implantation. To predict the effect of the presence of protons on X-ray production, we have proposed a new kinetic schema...

  6. SMM X-ray polychromator

    Science.gov (United States)

    Strong, Keith T.; Haisch, Bernhard M. (Compiler); Lemen, James R. (Compiler); Acton, L. W.; Bawa, H. S.; Claflin, E. S.; Freeland, S. L.; Slater, G. L.; Kemp, D. L.; Linford, G. A.

    1988-01-01

    The range of observing and analysis programs accomplished with the X-Ray Polychromator (XRP) instruments during the decline of solar cycle 21 and the rise of the solar cycle 22 is summarized. Section 2 describes XRP operations and current status. This is meant as a guide on how the instrument is used to obtain data and what its capabilities are for potential users. The science section contains a series of representative abstracts from recently published papers on major XRP science topics. It is not meant to be a complete list but illustrates the type of science that can come from the analysis of the XRP data. There then follows a series of appendixes that summarize the major data bases that are available. Appendix A is a complete bibliography of papers and presentations produced using XRP data. Appendix B lists all the spectroscopic data accumulated by the Flat Crystal Spectrometer (FCS). Appendix C is a compilation of the XRP flare catalogue for events equivalent to a GOES C-level flare or greater. It lists the start, peak and end times as well as the peak Ca XIX flux.

  7. X-ray computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kalender, Willi A [Institute of Medical Physics, University Erlangen-Nuernberg, Henkestr. 91, D-91052 Erlangen (Germany)

    2006-07-07

    X-ray computed tomography (CT), introduced into clinical practice in 1972, was the first of the modern slice-imaging modalities. To reconstruct images mathematically from measured data and to display and to archive them in digital form was a novelty then and is commonplace today. CT has shown a steady upward trend with respect to technology, performance and clinical use independent of predictions and expert assessments which forecast in the 1980s that it would be completely replaced by magnetic resonance imaging. CT not only survived but exhibited a true renaissance due to the introduction of spiral scanning which meant the transition from slice-by-slice imaging to true volume imaging. Complemented by the introduction of array detector technology in the 1990s, CT today allows imaging of whole organs or the whole body in 5 to 20 s with sub-millimetre isotropic resolution. This review of CT will proceed in chronological order focussing on technology, image quality and clinical applications. In its final part it will also briefly allude to novel uses of CT such as dual-source CT, C-arm flat-panel-detector CT and micro-CT. At present CT possibly exhibits a higher innovation rate than ever before. In consequence the topical and most recent developments will receive the greatest attention. (review)

  8. Design and experimental study of a two-dimensional position sensitive X-ray detector

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    A prototype of a two-dimensional position sensitive X-ray detector was designed and constructed for small angle X-ray scattering experiments at BSFR (Beijing Synchrotron Radiation Facility). The detector is based on MWPC with cathode strip readout, and has a sensitive area of 200 mmx200 mm. The spatial resolution (FWHM) of about 210 μm along the anode wire direction was obtained from the 55Fe X-ray test of the detector.

  9. Enhancement of X-ray detection by single-walled carbon nanotube enriched flexible polymer composite

    OpenAIRE

    Han, Heetak; Lee, Sanggeun; Seo, Jungmok; Mahata, Chandreswar; Cho, Sung Hwan; Han, A-Reum; Hong, Keun-Sung; Park, Joon-Ho; Soh, Myung-Jin; Park, Cheolmin; Lee, Taeyoon

    2014-01-01

    Abstract Although organic-based direct conversion X-ray detectors have been developed, their photocurrent generation efficiency has been limited by recombination of excitons due to the intrinsically poor electrical properties of organic materials. In this report, we fabricated a polymer-based flexible X-ray detector and enhanced the X-ray detection sensitivity using a single-walled carbon nanotube (SWNT) enriched polymer composite. When this SWNT enriched polymer composite was used as the act...

  10. Recent advances in X-ray compatible microfluidics for applications in soft materials and life sciences

    DEFF Research Database (Denmark)

    Ghazal, Aghiad; Lafleur, Josiane P; Mortensen, Kell

    2016-01-01

    preparation. Microfluidic-based sample preparation techniques have emerged as elegant alternatives that can be integrated directly into the experimental X-ray setup remedying several shortcomings of more traditional methods. We review the use of microfluidic devices in conjunction with X-ray measurements...... at large scale X-ray facilities is still emerging and far from mature, but it definitely offers an exciting array of new possibilities....

  11. Soft x-ray imaging by a commercial solid-state television camera

    Science.gov (United States)

    Matsushima, Isao; Koyama, Kazuyoshi; Tanimoto, Mitsumori; Yano, Masaaki

    1987-04-01

    A commerical, solid-state television camera has been used to record images of soft x radiation (0.8-12 keV). The performance of the camera is theoretically analyzed and experimentally evaluated compared with an x-ray photographic film (Kodak direct exposure film). In the application, the camera has been used to provide image patterns of x rays from laser-produced plasmas. It is demonstrated that the camera has several advantages over x-ray photographic film.

  12. Soft x-ray imaging by a commercial solid-state television camera

    Energy Technology Data Exchange (ETDEWEB)

    Matsushima, I.; Koyama, K.; Tanimoto, M.; Yano, M.

    1987-04-01

    A commerical, solid-state television camera has been used to record images of soft x radiation (0.8--12 keV). The performance of the camera is theoretically analyzed and experimentally evaluated compared with an x-ray photographic film (Kodak direct exposure film). In the application, the camera has been used to provide image patterns of x rays from laser-produced plasmas. It is demonstrated that the camera has several advantages over x-ray photographic film.

  13. Opening a New Window to Fundamental Physics and Astrophysics: X-ray Polarimetry

    CERN Document Server

    Costa, E; Soffitta, P; Persio, G; Feroci, M; Morelli, E; Muleri, F; Pacciani, L; Rubini, A; Baldini, L; Bitti, F; Brez, A; Cavalca, F; Latronico, L; Massai, M M; Omodei, N; Sgro', C; Spandre, G; Matt, G; Perola, G C; Santangelo, A; Celotti, A; Barret, D; Vilhu, O; Piro, L; Fraser, G; Courvoisier, T J L; Barcons, X

    2006-01-01

    An extensive theoretical literature predicts that X-ray Polarimetry can directly determine relevant physical and geometrical parameters of astrophysical sources, and discriminate between models further than allowed by spectral and timing data only. X-ray Polarimetry can also provide tests of Fundamental Physics. A high sensitivity polarimeter in the focal plane of a New Generation X-ray telescope could open this new window in the High Energy Sky.

  14. Ancient administrative handwritten documents: X-ray analysis and imaging

    Energy Technology Data Exchange (ETDEWEB)

    Albertin, F., E-mail: fauzia.albertin@epfl.ch [Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland); Astolfo, A. [Paul Scherrer Institut (PSI), Villigen (Switzerland); Stampanoni, M. [Paul Scherrer Institut (PSI), Villigen (Switzerland); ETHZ, Zürich (Switzerland); Peccenini, Eva [University of Ferrara (Italy); Technopole of Ferrara (Italy); Hwu, Y. [Academia Sinica, Taipei, Taiwan (China); Kaplan, F. [Ecole Polytechnique Fédérale de Lausanne (EPFL) (Switzerland); Margaritondo, G. [Ecole Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland)

    2015-01-30

    The heavy-element content of ink in ancient administrative documents makes it possible to detect the characters with different synchrotron imaging techniques, based on attenuation or refraction. This is the first step in the direction of non-interactive virtual X-ray reading. Handwritten characters in administrative antique documents from three centuries have been detected using different synchrotron X-ray imaging techniques. Heavy elements in ancient inks, present even for everyday administrative manuscripts as shown by X-ray fluorescence spectra, produce attenuation contrast. In most cases the image quality is good enough for tomography reconstruction in view of future applications to virtual page-by-page ‘reading’. When attenuation is too low, differential phase contrast imaging can reveal the characters from refractive index effects. The results are potentially important for new information harvesting strategies, for example from the huge Archivio di Stato collection, objective of the Venice Time Machine project.

  15. X-Ray Shadowing Experiments Toward Infrared Dark Clouds

    Science.gov (United States)

    Anderson, L. E.; Snowden, S.; Bania, T. M.

    2009-01-01

    We searched for X-ray shadowing toward two infrared dark clouds (IRDCs) using the MOS detectors on XMM-Newton to learn about the Galactic distribution of X-ray emitting plasma. IRDCs make ideal X-ray shadowing targets of 3/4 keY photons due to their high column densities, relatively large angular sizes, and known kinematic distances. Here we focus on two clouds near 30 deg Galactic longitude at distances of 2 and 5 kpc from the Sun. We derive the foreground and background column densities of molecular and atomic gas in the direction of the clouds. We find that the 3/4 ke V emission must be distributed throughout the Galactic disk. It is therefore linked to the structure of the cooler material of the ISM, and to the birth of stars.

  16. Detection of buried landmine with X-ray backscatter technique

    Energy Technology Data Exchange (ETDEWEB)

    Yuk, Sunwoo [Department of Electronics and Information Engineering, Korea University, Seoul (Korea, Republic of)]. E-mail: sunwoo@korea.ac.kr; Kim, Kwang Hyun [Chosun University, 375, Seosuk-Dong, Dong-Gu, Gwangju (Korea, Republic of); Yi, Yun [Department of Electronics and Information Engineering, Korea University, Seoul (Korea, Republic of)

    2006-11-30

    We describe a continuously operating scanning X-ray imaging system developed for landmine detection based on a backscatter X-ray principle, thus detection is done from the same side as the source. The source operates at 120 kV p and 3 mA. To study the physics of Compton X-ray backscattering, the photon transport factor, backscatter factor (BSF) and backscatter probability (BSP) were simulated using Monte-Carlo calculations using the generalized particle transport program MCNP. Based on the Monte-Carlo analyses results, a mine detecting system has been designed. It potentially has a low false alarm rate and a high detection probability, and a direct imaging facility.

  17. X-ray targeted bond or compound destruction

    Energy Technology Data Exchange (ETDEWEB)

    Pravica, Sr., Michael G.

    2016-11-01

    This document provides methods, systems, and devices for inducing a decomposition reaction by directing x-rays towards a location including a particular compound. The x-rays can have an irradiation energy that corresponds to a bond distance of a bond in the particular compound in order to break that bond and induce a decomposition of that particular compound. In some cases, the particular compound is a hazardous substance or part of a hazardous substance. In some cases, the particular compound is delivered to a desired location in an organism and x-rays induce a decomposition reaction that creates a therapeutic substance (e.g., a toxin that kills cancer cells) in the location of the organism. In some cases, the particular compound decomposes to produce a reactant in a reactor apparatus (e.g., fuel cell or semiconductor fabricator).

  18. X-ray natural circular dichroism in copper metaborate

    Energy Technology Data Exchange (ETDEWEB)

    Ovchinnikova, E. N. [Moscow State University (Russian Federation); Rogalev, A.; Wilhelm, F. [European Synchrotron Radiation Facility (France); Kozlovskaya, K. A.; Oreshko, A. P., E-mail: ap.oreshko@physics.msu.ru [Moscow State University (Russian Federation); Dmitrienko, V. E. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2016-07-15

    The local electronic structure of copper ions in a copper metaborate CuB{sub 2}O{sub 4} crystal is studied on the ESRF synchrotron using X-ray absorption polarization-dependent spectroscopy. The X-ray natural circular dichroism near the K absorption edge of copper is measured in the direction that is perpendicular to crystal axis c. The data obtained indicate the presence of hybridized p–d electronic states of copper. Theoretical calculations are used to separate the contributions of the two crystallographically nonequivalent positions of copper atoms in the unit cell of CuB{sub 2}O{sub 4} to the absorption and X-ray circular dichroism spectra of the crystal.

  19. The Herbig Ae Star HD 163296 in X-Rays

    Science.gov (United States)

    Swartz, Douglas A.; Drake, Jeremy J.; Elsner, Ronald F.; Ghosh, Kajal K.; Grady, Carol A.; Wassell, Edward

    2004-01-01

    Chandra X-ray imaging spectroscopy of the nearby Herbig Ae star HD 163296 at 100 AU angular resolution is reported. A point-like, soft (kT approximately 0.5 approximately kev), emission-line source is detected at the location of the star with an X-ray luminosity of 4.0e29 erg/s. In addition, faint emission along the direction of a previously-detected Ly-alpha-emitting jet and Herbig-Haro outflow may be present. The relatively low luminosity, lack of a hard spectral component, and absence of strong X-ray variability in HD 163296 can be explained as originating from optically-thin shock-heated gas accreting onto the stellar surface along magnetic field lines. This would require a (dipole) magnetic field strength at the surface of HD 163296 of at least approximately 100 approximately G and perhaps as high as several kG.

  20. Magnetic x-ray dichroism in ultrathin epitaxial films

    Energy Technology Data Exchange (ETDEWEB)

    Tobin, J.G.; Goodman, K.W. [Lawrence Berkeley National Lab., CA (United States); Cummins, T.R. [Univ. of Missouri, Rolla, MO (United States)] [and others

    1997-04-01

    The authors have used Magnetic X-ray Linear Dichroism (MXLD) and Magnetic X-ray Circular Dichroism (MXCD) to study the magnetic properties of epitaxial overlayers in an elementally specific fashion. Both MXLD and MXCD Photoelectron Spectroscopy were performed in a high resolution mode at the Spectromicroscopy Facility of the ALS. Circular Polarization was obtained via the utilization of a novel phase retarder (soft x-ray quarter wave plate) based upon transmission through a multilayer film. The samples were low temperature Fe overlayers, magnetic alloy films of NiFe and CoNi, and Gd grown on Y. The authors results include a direct comparison of high resolution angle resolved Photoelectron Spectroscopy performed in MXLD and MXCD modes as well as structural studies with photoelectron diffraction.

  1. 30S Beam Development and X-ray Bursts

    CERN Document Server

    Kahl, D; Kubono, S; Binh, D N; Chen, J; Hashimoto, T; Hayakawa, S; Kaji, D; Kim, A; Kurihara, Y; Lee, N H; Nishimura, S; Ohshiro, Y; nia, K Setoodeh; Wakabayashi, Y; Yamaguchi, H; 10.1063/1.3362583

    2010-01-01

    Over the past three years, we have worked on developing a well-characterized 30S radioactive beam to be used in a future experiment aiming to directly measure the 30S(alpha,p) stellar reaction rate within the Gamow window of Type I X-ray bursts. The importance of the 30S(alpha,p) reaction to X-ray bursts is discussed. Given the astrophysical motivation, the successful results of and challenges involved in the production of a low-energy 30S beam are detailed. Finally, an overview of our future plans regarding this on-going project are presented.

  2. Image processing system for digital chest X-ray images

    Energy Technology Data Exchange (ETDEWEB)

    Cocklin, M.; Gourlay, A.; Jackson, P.; Kaye, G.; Miessler, M. (I.B.M. U.K. Scientific Centre, Winchester (UK)); Kerr, I.; Lams, P. (Radiology Department, Brompton Hospital, London (UK))

    1984-01-01

    This paper investigates the requirements for image processing of digital chest X-ray images. These images are conventionally recorded on film and are characterised by large size, wide dynamic range and high resolution. X-ray detection systems are now becoming available for capturing these images directly in photoelectronic-digital form. The hardware and software facilities required for handling these images are described. These facilities include high resolution digital image displays, programmable video look up tables, image stores for image capture and processing and a full range of software tools for image manipulation. Examples are given of the applications of digital image processing techniques to this class of image.

  3. Acoustically modulated x-ray phase contrast imaging.

    Science.gov (United States)

    Hamilton, Theron J; Bailat, Claude J; Rose-Petruck, Christoph; Diebold, Gerald J

    2004-11-07

    We report the use of ultrasonic radiation pressure with phase contrast x-ray imaging to give an image proportional to the space derivative of a conventional phase contrast image in the direction of propagation of an ultrasonic beam. Intense ultrasound is used to exert forces on objects within a body giving displacements of the order of tens to hundreds of microns. Subtraction of images made with and without the ultrasound field gives an image that removes low spatial frequency features and highlights high frequency features. The method acts as an acoustic 'contrast agent' for phase contrast x-ray imaging, which in soft tissue acts to highlight small density changes.

  4. Diffraction leveraged modulation of X-ray pulses using MEMS-based X-ray optics

    Science.gov (United States)

    Lopez, Daniel; Shenoy, Gopal; Wang, Jin; Walko, Donald A.; Jung, Il-Woong; Mukhopadhyay, Deepkishore

    2016-08-09

    A method and apparatus are provided for implementing Bragg-diffraction leveraged modulation of X-ray pulses using MicroElectroMechanical systems (MEMS) based diffractive optics. An oscillating crystalline MEMS device generates a controllable time-window for diffraction of the incident X-ray radiation. The Bragg-diffraction leveraged modulation of X-ray pulses includes isolating a particular pulse, spatially separating individual pulses, and spreading a single pulse from an X-ray pulse-train.

  5. X-ray lasers: Multicolour emission

    Science.gov (United States)

    Feng, Chao; Deng, Haixiao

    2016-11-01

    The X-ray free-electron laser at the SLAC National Accelerator Laboratory in the US can now generate multicolour X-ray pulses with unprecedented brightness using the fresh-slice technique. The development opens the way to new forms of spectroscopy.

  6. X-Ray Detection Visits the Classroom

    Science.gov (United States)

    Peralta, Luis; Farinha, Ana; Pinto, Ana

    2008-01-01

    Film has been used to detect x-rays since the early days of their discovery by Rontgen. Although nowadays superseded by other techniques, film still provides a cheap means of x-ray detection, making it attractive in high-school or undergraduate university courses. If some sort of quantitative result is required, the film's optical absorbance or…

  7. Accelerator-driven X-ray Sources

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dinh Cong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-11-09

    After an introduction which mentions x-ray tubes and storage rings and gives a brief review of special relativity, the subject is treated under the following topics and subtopics: synchrotron radiation (bending magnet radiation, wiggler radiation, undulator radiation, brightness and brilliance definition, synchrotron radiation facilities), x-ray free-electron lasers (linac-driven X-ray FEL, FEL interactions, self-amplified spontaneous emission (SASE), SASE self-seeding, fourth-generation light source facilities), and other X-ray sources (energy recovery linacs, Inverse Compton scattering, laser wakefield accelerator driven X-ray sources. In summary, accelerator-based light sources cover the entire electromagnetic spectrum. Synchrotron radiation (bending magnet, wiggler and undulator radiation) has unique properties that can be tailored to the users’ needs: bending magnet and wiggler radiation is broadband, undulator radiation has narrow spectral lines. X-ray FELs are the brightest coherent X-ray sources with high photon flux, femtosecond pulses, full transverse coherence, partial temporal coherence (SASE), and narrow spectral lines with seeding techniques. New developments in electron accelerators and radiation production can potentially lead to more compact sources of coherent X-rays.

  8. X-raying clumped stellar winds

    CERN Document Server

    Oskinova, L M; Feldmeier, A

    2008-01-01

    X-ray spectroscopy is a sensitive probe of stellar winds. X-rays originate from optically thin shock-heated plasma deep inside the wind and propagate outwards throughout absorbing cool material. Recent analyses of the line ratios from He-like ions in the X-ray spectra of O-stars highlighted problems with this general paradigm: the measured line ratios of highest ions are consistent with the location of the hottest X-ray emitting plasma very close to the base of the wind, perhaps indicating the presence of a corona, while measurements from lower ions conform with the wind-embedded shock model. Generally, to correctly model the emerging X-ray spectra, a detailed knowledge of the cool wind opacities based on stellar atmosphere models is prerequisite. A nearly grey stellar wind opacity for the X-rays is deduced from the analyses of high-resolution X-ray spectra. This indicates that the stellar winds are strongly clumped. Furthermore, the nearly symmetric shape of X-ray emission line profiles can be explained if t...

  9. Cryogenic imaging x-ray spectrometer

    NARCIS (Netherlands)

    Wiegerink, Remco J.; van Baar, J.J.J.; de Boer, J.H.; Ridder, M.L.; Bruijn, M.P.; Germeau, A.; Hoevers, H.F.C.

    2005-01-01

    A micro-calorimeter array consisting of superconducting transition-edge sensors is under development for the X-ray imaging spectrometer on board of ESA's XEUS (X-ray Evolving Universe Spectroscopy) mission. An array of 32 /spl times/ 32 pixels with a pixel size of 250 micron square is envisaged. So

  10. Low Energy X-Ray Diagnostics - 1981.

    Science.gov (United States)

    1981-01-01

    Filtering, and Scattering of Soft X-Rays by Mirrors Victor Rehn Michelson Laboratory, Physics Division Naval Weapons Center, China Lake, California...met with in K.Tregidgo, 18, 2003 (1979). the manufacture of X-ray optical components. In 32. W.P.Linnik, C. R. Acad. Sci. URSS ., 5, 210 (1933). general

  11. Soft X-ray techniques to study mesoscale magnetism

    Energy Technology Data Exchange (ETDEWEB)

    Kortright, Jeffrey B.

    2003-06-26

    Heterogeneity in magnetization (M) is ubiquitous in modern systems. Even in nominally homogeneous materials, domains or pinning centers typically mediate magnetization reversal. Fundamental lengths determining M structure include the domain wall width and the exchange stiffness length, typically in the 4-400 nm range. Chemical heterogeneity (phase separation, polycrystalline microstructure, lithographic or other patterning, etc.) with length scales from nanometers to microns is often introduced to influence magnetic properties. With 1-2 nm wavelengths {lambda}, soft x-rays in principle can resolve structure down to {lambda}/2, and are well suited to study these mesoscopic length scales [1, 2]. This article highlights recent advances in resonant soft x-ray methods to resolve lateral magnetic structure [3], and discusses some of their relative merits and limitations. Only techniques detecting x-ray photons (rather than photo-electrons) are considered [4], since they are compatible with strong applied fields to probe relatively deeply into samples. The magneto-optical (MO) effects discovered by Faraday and Kerr were observed in the x-ray range over a century later, first at ''hard'' wavelengths in diffraction experiments probing interatomic magnetic structure [5]. In the soft x-ray range, magnetic linear [6] and circular [7] dichroism spectroscopies first developed that average over lateral magnetic structure. These large resonant MO effects enable different approaches to study magnetic structure or heterogeneity that can be categorized as microscopy or scattering [1]. Direct images of magnetic structure result from photo-emission electron microscopes [4, 8] and zone-plate microscopes [9, 10]. Scattering techniques extended into the soft x-ray include familiar specular reflection that laterally averages over structure but can provide depth-resolved information, and diffuse scattering and diffraction that provide direct information about lateral

  12. The NuSTAR Extragalactic Surveys: First Direct Measurements of the >10 keV X-Ray Luminosity Function for Active Galactic Nuclei at z>0.1

    CERN Document Server

    Aird, J; Ballantyne, D R; Civano, F; Del-Moro, A; Hickox, R C; Lansbury, G B; Mullaney, J R; Bauer, F E; Brandt, W N; Comastri, A; Fabian, A C; Gandhi, P; Harrison, F A; Luo, B; Stern, D; Treister, E; Zappacosta, L; Ajello, M; Assef, R; Boggs, S E; Brightman, M; Christensen, F E; Craig, W W; Elvis, M; Forster, K; Balokovic, M; Grefenstette, B W; Hailey, C J; Koss, M; LaMassa, S M; Madsen, K K; Puccetti, S; Saez, C; Urry, C M; Wik, D R; Zhang, W

    2015-01-01

    We present the first direct measurements of the rest-frame 10-40 keV X-ray luminosity function (XLF) of Active Galactic Nuclei (AGNs) based on a sample of 94 sources at 0.1 < z <3, selected at 8-24 keV energies from sources in the NuSTAR extragalactic survey program. Our results are consistent with the strong evolution of the AGN population seen in prior, lower-energy studies of the XLF. However, different models of the intrinsic distribution of absorption, which are used to correct for selection biases, give significantly different predictions for the total number of sources in our sample, leading to small, systematic differences in our binned estimates of the XLF. Adopting a model with a lower intrinsic fraction of Compton-thick sources and a larger population of sources with column densities N_H ~ 10^{23-24} /cm2 or a model with stronger Compton reflection component (with a relative normalization of R ~ 2 at all luminosities) can bring extrapolations of the XLF from 2-10 keV into agreement with our N...

  13. New Insights into X-ray Binaries

    CERN Document Server

    Casares, Jorge

    2009-01-01

    X-ray binaries are excellent laboratories to study collapsed objects. On the one hand, transient X-ray binaries contain the best examples of stellar-mass black holes while persistent X-ray binaries mostly harbour accreting neutron stars. The determination of stellar masses in persistent X-ray binaries is usually hampered by the overwhelming luminosity of the X-ray heated accretion disc. However, the discovery of high-excitation emission lines from the irradiated companion star has opened new routes in the study of compact objects. This paper presents novel techniques which exploits these irradiated lines and summarises the dynamical masses obtained for the two populations of collapsed stars: neutron stars and black holes.

  14. An X-ray view of quasars

    CERN Document Server

    Singh, K P

    2013-01-01

    I present an overview of observational studies of quasars of all types, with particular emphasis on X-ray observational studies. The presentation is based on the most popularly accepted unified picture of quasars - collectively referred to as AGN (active galactic nuclei) in this review. Characteristics of X-ray spectra and X-ray variability obtained from various X-ray satellites over the last 5 decades have been presented and discussed. The contribution of AGN in understanding the cosmic X-ray background is discussed very briefly. Attempt has been made to provide up-to-date information; however, this is a vast subject and this presentation is not intended to be comprehensive.

  15. LOBSTER - New Space X-Ray telescopes

    Energy Technology Data Exchange (ETDEWEB)

    Hudec, R. [Astronomical Institute, Academy of Sciences of the Czech Republic, CZ-251 65 Ondrejov (Czech Republic); Pina, L. [Faculty of Nuclear Science, Czech Technical University, Prague (Czech Republic); Simon, V. [Astronomical Institute, Academy of Sciences of the Czech Republic, CZ-251 65 Ondrejov (Czech Republic); Sveda, L. [Faculty of Nuclear Science, Czech Technical University, Prague (Czech Republic); Inneman, A.; Semencova, V. [Center for Advanced X-ray Technologies, Reflex, Prague (Czech Republic); Skulinova, M. [Astronomical Institute, Academy of Sciences of the Czech Republic, CZ-251 65 Ondrejov (Czech Republic)

    2007-04-15

    We discuss the technological and scientific aspects of fully innovative very wide-field X-ray telescopes with high sensitivity. The prototypes of Lobster telescopes designed, developed and tested are very promising, allowing the proposals for space projects with very wide-field Lobster Eye X-ray optics to be considered for the first time. The novel telescopes will monitor the sky with unprecedented sensitivity and angular resolution of order of 1 arcmin. They are expected to contribute essentially to study of various astrophysical objects such as AGN, SNe, Gamma-ray bursts (GRBs), X-ray flashes (XRFs), galactic binary sources, stars, CVs, X-ray novae, various transient sources, etc. For example, the Lobster optics based X-ray All Sky Monitor is capable to detect around 20 GRBs and 8 XRFs yearly and this will surely significantly contribute to the related science.

  16. High Energy Vision: Processing X-rays

    CERN Document Server

    DePasquale, Joseph; Edmonds, Peter

    2015-01-01

    Astronomy is by nature a visual science. The high quality imagery produced by the world's observatories can be a key to effectively engaging with the public and helping to inspire the next generation of scientists. Creating compelling astronomical imagery can, however, be particularly challenging in the non-optical wavelength regimes. In the case of X-ray astronomy, where the amount of light available to create an image is severely limited, it is necessary to employ sophisticated image processing algorithms to translate light beyond human vision into imagery that is aesthetically pleasing while still being scientifically accurate. This paper provides a brief overview of the history of X-ray astronomy leading to the deployment of NASA's Chandra X-ray Observatory, followed by an examination of the specific challenges posed by processing X-ray imagery. The authors then explore image processing techniques used to mitigate such processing challenges in order to create effective public imagery for X-ray astronomy. ...

  17. Globular Cluster X-ray Sources

    CERN Document Server

    Verbunt, F

    2004-01-01

    After a brief historical overview we discuss the luminous X-ray sources in globular clusters of our Galaxy. This is followed by an overview of the very luminous X-ray sources studied in globular clusters of 14 other galaxies, and a discussion of their formation and the relation to X-ray sources outside globular clusters. We describe the discovery and classification of low-luminosity X-ray sources, and end the review with some remarks on the formation and evolution of X-ray sources in globular clusters. Observational results are summarized in three tables. Comments are very welcome. Please send them to F.W.M.Verbunt@astro.uu.nl and lewin@mit.edu.

  18. X-Rays from Green Pea Analogs

    Science.gov (United States)

    Brorby, Matthew

    2014-09-01

    X-rays may have contributed to the heating and reionization of the IGM in the early universe. High mass X-ray binaries (HMXB) within small, low-metallicity galaxies are expected to be the main source of X-rays at this time. Since studying these high-redshift galaxies is currently impossible, we turn to local analogs that have the same properties the galaxies in the early are expected to have. A number of recent studies have shown an enhanced number of HMXBs in nearby low metallicity galaxies. We propose to observe a sample of metal-deficient luminous compact galaxies (LCG) in order to determine if the X-ray luminosity is enhanced relative to SFR, thereby providing further evidence to the importance of X-rays in the early universe.

  19. X-ray Fourier ptychographic microscopy

    CERN Document Server

    Simons, H; Guigay, J P; Detlefs, C

    2016-01-01

    Following the recent developement of Fourier ptychographic microscopy (FPM) in the visible range by Zheng et al. (2013), we propose an adaptation for hard x-rays. FPM employs ptychographic reconstruction to merge a series of low-resolution, wide field of view images into a high-resolution image. In the x-ray range this opens the possibility to overcome the limited numerical aperture of existing x-ray lenses. Furthermore, digital wave front correction (DWC) may be used to charaterize and correct lens imperfections. Given the diffraction limit achievable with x-ray lenses (below 100 nm), x-ray Fourier ptychographic microscopy (XFPM) should be able to reach resolutions in the 10 nm range.

  20. X-ray diffraction: instrumentation and applications.

    Science.gov (United States)

    Bunaciu, Andrei A; Udriştioiu, Elena Gabriela; Aboul-Enein, Hassan Y

    2015-01-01

    X-ray diffraction (XRD) is a powerful nondestructive technique for characterizing crystalline materials. It provides information on structures, phases, preferred crystal orientations (texture), and other structural parameters, such as average grain size, crystallinity, strain, and crystal defects. X-ray diffraction peaks are produced by constructive interference of a monochromatic beam of X-rays scattered at specific angles from each set of lattice planes in a sample. The peak intensities are determined by the distribution of atoms within the lattice. Consequently, the X-ray diffraction pattern is the fingerprint of periodic atomic arrangements in a given material. This review summarizes the scientific trends associated with the rapid development of the technique of X-ray diffraction over the past five years pertaining to the fields of pharmaceuticals, forensic science, geological applications, microelectronics, and glass manufacturing, as well as in corrosion analysis.

  1. X-ray modeling for SMILE

    Science.gov (United States)

    Sun, T.; Wang, C.; Wei, F.; Liu, Z. Q.; Zheng, J.; Yu, X. Z.; Sembay, S.; Branduardi-Raymont, G.

    2016-12-01

    SMILE (Solar wind Magnetosphere Ionosphere Link Explorer) is a novel mission to explore the coupling of the solar wind-magnetosphere-ionosphere system via providing global images of the magnetosphere and aurora. As the X-ray imaging is a brand new technique applied to study the large scale magnetopause, modeling of the solar wind charge exchange (SWCX) X-ray emissions in the magnetosheath and cusps is vital in various aspects: it helps the design of the Soft X-ray Imager (SXI) on SMILE, selection of satellite orbits, as well as the analysis of expected scientific outcomes. Based on the PPMLR-MHD code, we present the simulation results of the X-ray emissions in geospace during storm time. Both the polar orbit and the Molniya orbit are used. From the X-ray images of the magnetosheath and cusps, the magnetospheric responses to an interplanetary shock and IMF southward turning are analyzed.

  2. Sample Environment in Experiments using X-Ray Synchrotron Radiation

    DEFF Research Database (Denmark)

    Buras, B

    1984-01-01

    Modern electron (positron) storage rings are able to emit very intense X-ray radiation with a continuous spectrum extending to 0.1 A, from bending magnets and insertion devices (wavelength shifters and multipole wigglers). It can be used directly for white beam experiments and/or for monochromati...

  3. Data Calculation of X-Ray Arising From Nuclear Decay

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The x-ray data are relevant in nuclear decay data. In a gamma transition process, gamma transition energy will be transferred directly to an orbital electron in different atomic shells throughelectronic-magnetic interaction. The orbital electrons which have gotten transition energies overcomeatomic-electron binding energy and will emit out from different atomic shells, and leave vacancies. In an

  4. The Large Observatory for X-ray Timing (LOFT)

    NARCIS (Netherlands)

    Feroci, M.; Stella, L.; van der Klis, M.; Courvoisier, T.J.L.; Hernanz, M.; Hudec, R.; Santangelo, A.; Walton, D.; Zdziarski, A.; Barret, D.; Belloni, T.; Braga, J.; Brandt, S.; Budtz-Jørgensen, C.; Campana, S.; den Herder, J.W.; Huovelin, J.; Israel, G.L.; Pohl, M.; Ray, P.; Vacchi, A.; Zane, S.; Argan, A.; Attinà, P.; Bertuccio, G.; Bozzo, E.; Campana, R.; Chakrabarty, D.; Costa, E.; De Rosa, A.; Del Monte, E.; Di Cosimo, S.; Donnarumma, I.; Evangelista, Y.; Haas, D.; Jonker, P.; Korpela, S.; Labanti, C.; Malcovati, P.; Mignani, R.; Muleri, F.; Rapisarda, M.; Rashevsky, A.; Rea, N.; Rubini, A.; Tenzer, C.; Wilson-Hodge, C.; Winter, B.; Wood, K.; Zampa, G.; Zampa, N.; Abramowicz, M.A.; Alpar, M.A.; Altamirano, D.; Alvarez, J.M.; Amati, L.; Amoros, C.; Antonelli, L.A.; Artigue, R.; Azzarello, P.; Bachetti, M.; Baldazzi, G.; Barbera, M.; Barbieri, C.; Basa, S.; Baykal, A.; Belmont, R.; Boirin, L.; Bonvicini, V.; Burderi, L.; Bursa, M.; Cabanac, C.; Cackett, E.; Caliandro, G.A.; Casella, P.; Chaty, S.; Chenevez, J.; Coe, M.J.; Collura, A.; Corongiu, A.; Covino, S.; Cusumano, G.; D'Amico, F.; Dall'Osso, S.; De Martino, D.; De Paris, G.; Di Persio, G.; Di Salvo, T.; Done, C.; Dovčiak, M.; Drago, A.; Ertan, U.; Fabiani, S.; Falanga, M.; Fender, R.; Ferrando, P.; Della Monica Ferreira, D.; Fraser, G.; Frontera, F.; Fuschino, F.; Galvez, J.L.; Gandhi, P.; Giommi, P.; Godet, O.; Göǧüş, E.; Goldwurm, A.; Götz, D.; Grassi, M.; Guttridge, P.; Hakala, P.; Henri, G.; Hermsen, W.; Horak, J.; Hornstrup, A.; in 't Zand, J.J.M.; Isern, J.; Kalemci, E.; Kanbach, G.; Karas, V.; Kataria, D.; Kennedy, T.; Klochkov, D.; Kluźniak, W.; Kokkotas, K.; Kreykenbohm, I.; Krolik, J.; Kuiper, L.; Kuvvetli, I.; Kylafis, N.; Lattimer, J.M.; Lazzarotto, F.; Leahy, D.; Lebrun, F.; Lin, D.; Lund, N.; Maccarone, T.; Malzac, J.; Marisaldi, M.; Martindale, A.; Mastropietro, M.; McClintock, J.; McHardy, I.; Mendez, M.; Mereghetti, S.; Miller, M.C.; Mineo, T.; Morelli, E.; Morsink, S.; Motch, C.; Motta, S.; Muñoz-Darias, T.; Naletto, G.; Neustroev, V.; Nevalainen, J.; Olive, J.F.; Orio, M.; Orlandini, M.; Orleanski, P.; Ozel, F.; Pacciani, L.; Paltani, S.; Papadakis, I.E.; Papitto, A.; Patruno, A.; Pellizzoni, A.; Petráček, V.; Petri, J.; Petrucci, P.O.; Phlips, B.; Picolli, L.; Possenti, A.; Psaltis, D.; Rambaud, D.; Reig, P.; Remillard, R.; Rodriguez, J.; Romano, P.; Romanova, M.; Schanz, T.; Schmid, C.; Segreto, A.; Shearer, A.; Smith, A.; Smith, P.J.; Soffitta, P.; Stergioulas, N.; Stolarski, M.; Stuchlik, Z.; Tiengo, A.; Torres, D.; Török, G.; Turolla, R.; Uttley, P.; Vaughan, S.; Vercellone, S.; Waters, R.; Watts, A.; Wawrzaszek, R.; Webb, N.; Wilms, J.; Zampieri, L.; Zezas, A.; Ziolkowski, J.

    2012-01-01

    High-time-resolution X-ray observations of compact objects provide direct access to strong-field gravity, to the equation of state of ultradense matter and to black hole masses and spins. A 10 m2-class instrument in combination with good spectral resolution is required to exploit the relevant diagno

  5. The Large Observatory for X-ray Timing (LOFT)

    NARCIS (Netherlands)

    Feroci, M.; Stella, L.; van der Klis, M.; Courvoisier, T. J.-L.; Hernanz, M.; Hudec, R.; Santangelo, A.; Walton, D.; Zdziarski, A.; Barret, D.; Belloni, T.; Braga, J.; Brandt, S.; Budtz-Jørgensen, C.; Campana, S.; den Herder, J.-W.; Huovelin, J.; Israel, G. L.; Pohl, M.; Ray, P.; Vacchi, A.; Zane, S.; Argan, A.; Attinà, P.; Bertuccio, G.; Bozzo, E.; Campana, R.; Chakrabarty, D.; Costa, E.; De Rosa, A.; Del Monte, E.; Di Cosimo, S.; Donnarumma, I.; Evangelista, Y.; Haas, D.; Jonker, P.; Korpela, S.; Labanti, C.; Malcovati, P.; Mignani, R.; Muleri, F.; Rapisarda, M.; Rashevsky, A.; Rea, N.; Rubini, A.; Tenzer, C.; Wilson-Hodge, C.; Winter, B.; Wood, K.; Zampa, G.; Zampa, N.; Abramowicz, M. A.; Alpar, M. A.; Altamirano, D.; Alvarez, J. M.; Amati, L.; Amoros, C.; Antonelli, L. A.; Artigue, R.; Azzarello, P.; Bachetti, M.; Baldazzi, G.; Barbera, M.; Barbieri, C.; Basa, S.; Baykal, A.; Belmont, R.; Boirin, L.; Bonvicini, V.; Burderi, L.; Bursa, M.; Cabanac, C.; Cackett, E.; Caliandro, G. A.; Casella, P.; Chaty, S.; Chenevez, J.; Coe, M. J.; Collura, A.; Corongiu, A.; Covino, S.; Cusumano, G.; D'Amico, F.; Dall'Osso, S.; De Martino, D.; De Paris, G.; Di Persio, G.; Di Salvo, T.; Done, C.; Dovčiak, M.; Drago, A.; Ertan, U.; Fabiani, S.; Falanga, M.; Fender, R.; Ferrando, P.; Della Monica Ferreira, D.; Fraser, G.; Frontera, F.; Fuschino, F.; Galvez, J. L.; Gandhi, P.; Giommi, P.; Godet, O.; Göǧüş, E.; Goldwurm, A.; Götz, D.; Grassi, M.; Guttridge, P.; Hakala, P.; Henri, G.; Hermsen, W.; Horak, J.; Hornstrup, A.; in't Zand, J. J. M.; Isern, J.; Kalemci, E.; Kanbach, G.; Karas, V.; Kataria, D.; Kennedy, T.; Klochkov, D.; Kluźniak, W.; Kokkotas, K.; Kreykenbohm, I.; Krolik, J.; Kuiper, L.; Kuvvetli, I.; Kylafis, N.; Lattimer, J. M.; Lazzarotto, F.; Leahy, D.; Lebrun, F.; Lin, D.; Lund, N.; Maccarone, T.; Malzac, J.; Marisaldi, M.; Martindale, A.; Mastropietro, M.; McClintock, J.; McHardy, I.; Mendez, M.; Mereghetti, S.; Miller, M. C.; Mineo, T.; Morelli, E.; Morsink, S.; Motch, C.; Motta, S.; Muñoz-Darias, T.; Naletto, G.; Neustroev, V.; Nevalainen, J.; Olive, J. F.; Orio, M.; Orlandini, M.; Orleanski, P.; Ozel, F.; Pacciani, L.; Paltani, S.; Papadakis, I.; Papitto, A.; Patruno, A.; Pellizzoni, A.; Petráček, V.; Petri, J.; Petrucci, P. O.; Phlips, B.; Picolli, L.; Possenti, A.; Psaltis, D.; Rambaud, D.; Reig, P.; Remillard, R.; Rodriguez, J.; Romano, P.; Romanova, M.; Schanz, T.; Schmid, C.; Segreto, A.; Shearer, A.; Smith, A.; Smith, P. J.; Soffitta, P.; Stergioulas, N.; Stolarski, M.; Stuchlik, Z.; Tiengo, A.; Torres, D.; Török, G.; Turolla, R.; Uttley, P.; Vaughan, S.; Vercellone, S.; Waters, R.; Watts, A.; Wawrzaszek, R.; Webb, N.; Wilms, J.; Zampieri, L.; Zezas, A.; Ziolkowski, J.

    2012-01-01

    High-time-resolution X-ray observations of compact objects provide direct access to strong-field gravity, to the equation of state of ultradense matter and to black hole masses and spins. A 10 m(2)-class instrument in combination with good spectral resolution is required to exploit the relevant diag

  6. Correlations between pulsed X-ray flux and radio arrival time in the Vela pulsar

    CERN Document Server

    Lommen, A N; Gwinn, C; Arzoumanian, Z; Harding, A; Strickman, M S; Dodson, R; McCulloch, P; Moffett, D

    2007-01-01

    We report the results of simultaneous observations of the Vela pulsar in X-rays and radio from the RXTE satellite and the Mount Pleasant Radio Observatory in Tasmania. We sought correlations between the Vela's X-ray and radio flux densities and radio arrival times on a pulse by pulse basis. We found significantly higher flux density in Vela's main X-ray peak during radio pulses that arrived early. This excess flux shifts to the 'trough' following the 2nd X-ray peak during radio pulses that arrive later. We suggest that the mechanism producing the radio pulses is intimately connected to the mechanism producing X-rays. Current models using resonant absorption in the outer magnetosphere as a cause of the radio emission, and less directly of the X-ray emission, are explored as a possible explanation for the correlation.

  7. The spatial, spectral and polarization properties of solar flare X-ray sources

    CERN Document Server

    Jeffrey, Natasha L S

    2014-01-01

    X-rays are a valuable diagnostic tool for the study of high energy accelerated electrons. Bremsstrahlung X-rays produced by, and directly related to, high energy electrons accelerated during a flare, provide a powerful diagnostic tool for determining both the properties of the accelerated electron distribution, and of the flaring coronal and chromospheric plasmas. This thesis is specifically concerned with the study of spatial, spectral and polarization properties of solar flare X-ray sources via both modelling and X-ray observations using the Ramaty High Energy Solar Spectroscopic Imager (RHESSI). Firstly, a new model is presented, accounting for finite temperature, pitch angle scattering and initial pitch angle injection. This is developed to accurately infer the properties of the acceleration region from the observations of dense coronal X-ray sources. Moreover, examining how the spatial properties of dense coronal X-ray sources change in time, interesting trends in length, width, position, number density ...

  8. Tabletop Ultrabright Kiloelectronvolt X-Ray Sources from Xe and Kr Hollow Atom States

    Science.gov (United States)

    Sankar, Poopalasingam

    Albert Einstein, the father of relativity, once said, "Look deep into nature, and then you will understand everything better". Today available higher resolution tabletop tool to look deep into matters and living thing is an x-ray source. Although the available tabletop x-rays sources of the 20th century, such as the ones used for medical or dental x-rays are tremendously useful for medical diagnostics and industry, a major disadvantage is that they have low quality skillful brightness, which limits its resolution and accuracy. In the other hand, x-ray free-electrons laser (XFEL) and synchrotron radiation sources provided extreme bright x-rays. However, number of applications of XFEL and synchrotron such as medical and industrials, has been hampered by their size, complexity, and cost. This has set a goal of demonstrating x-ray source with enough brightness for potential applications in an often-called tabletop compact x-ray source that could be operated in university laboratory or hospitals. We have developed two tabletop ultrabright keV x-ray sources, one from a Xe hollow-atom states and the other one from Kr hollow-atom stares with a unique characteristic that makes them complementary to currently-available extreme-light sources; XFEL, and synchrotron x-ray source. Upgraded tabletop ultra-fast KrF* pump-laser interacts with target rare-gas clusters and produces hollow-atom states, which later coherently collapse to the empty inner-shell and thereby generate keV x-ray radiation. The KrF* pump-laser beam is self-focused and forms a self-channel to guide the generated x-ray radiation in the direction of the pump-laser beam to produce directed x-ray beam. Xe (M) x-ray source operates at 1.2-1.6 nm wavelength while the Kr(L) x-ray source operates in 600-800 pm wavelength. System is mounted upon 3 optical-tables (5´x12´) with two KrF amplifiers at a repetition rate of 0.1 Hz. A lower bound for brightness value for both Xe and Kr x-ray sources is 1026 photons s-1mm-2

  9. Heterodyne-Detected Ultrafast X-Ray Diffraction and Scattering from Nonstationary States

    CERN Document Server

    Bennett, Kochise; Mukamel, Shaul

    2016-01-01

    Free-electron laser hard X-ray light sources can provide high fluence, femtosecond pulses, enabling the time-resolved probing of structural dynamics and elementary relaxation processes in molecules. Traditional X-ray elastic scattering from crystals in the ground state consists of sharp Bragg diffraction peaks that arise from pairs of molecules and reveal the ground state charge density. Scattering of ultrashort X-ray pulses from gases, liquids, and even single molecules is more complex and involves both single- and two- molecule contributions, diffuse (non-Bragg) features, elastic and inelastic components, contributions of electronic coherences in nonstationary states, and interferences between scattering off different states (heterodyne detection). We present a unified description that covers all these processes and discuss their relative magnitudes for gas-phase NaI. Conditions for the observation of holographic (heterodyne) interference, which has been recently discussed [1], are clarified.

  10. Comparison of image quality using a X-ray stereotactical whole-body system and a direct flat-panel X-ray device in examinations of the pelvis and knee; Bildqualitativer Vergleich eines roentgenstereotaktischen Ganzkoerperaufnahmesystems mit der direkten Flachdetektor-Radiografie anhand von Untersuchungen des Beckens und des Knies

    Energy Technology Data Exchange (ETDEWEB)

    Krug, K.B.; Weber, C.; Schwabe, H. [Klinikum der Koeln Univ. (Germany). Inst. fuer Radiologische Diagnostik; and others

    2014-01-15

    Purpose: The novel biplanar X-ray unit 'EOS', EOS Imaging, allows to acquire simultaneously 2 perpendicular planes of full-length spine and limbs and to measure spatially correct angles based on the acquired image data sets. This is to be seen alongside with a low spatial resolution, high investment costs and high operating expenses. The use of the biplanar X-ray unit in morphology based skeletal radiography might improve the cost-benefit-relation. Thus, the purpose of this study was to compare image quality of the EOS-unit and the flat panel (FP)-technology as reference in a clinical setting. Materials and Methods: All 114 patients of the Orthopedic Hospital Dept., who had a biplanar full-length lower limb radiograph and a FP-examination of the pelvis and/or the knee with maximum time interval of 3 months without changes in the clinical and radiological findings were included in the study. All X-ray examinations had been carried out due to clinical indications. Secondary captures comparable to the FP-images were extracted from the electronic EOS-image data sets. 4 radiologists independently from each other compared the visualization of normal anatomical structures of the pseudonymous EOS- and FP-images in a randomized order. Results: In the overview of all readers and all skeletal regions image quality of the FP-images was considered being superior in a mean of 83 {+-} 13 % standard deviation of the pair comparisons (minimum 48 %, maximum 100 %). Image quality of the EOS-images was assessed as being superior in 2 {+-} 3 % of the cases (0 %, 10 %). Image quality of 0.8 {+-} 3 % of the FP-images (0 %, 17 %) and 30 {+-} 34 % (0 %, 100 %) of the EOS-images was estimated as diagnostically inadequate. 30 {+-} 33 % of the pair comparisons (0 %, 100 %) showed a diagnostically inadequate image quality of the EOS-images and a diagnostically good image quality of the FP-images. Conclusion: Image quality of biplanar full-length lower limb X-ray examinations is not

  11. On the theory of time-resolved x-ray diffraction

    DEFF Research Database (Denmark)

    Henriksen, Niels Engholm; Møller, Klaus Braagaard

    2008-01-01

    We derive the basic theoretical formulation for X-ray diffraction with pulsed fields, using a fully quantized description of light and matter. Relevant time scales are discussed for coherent as well as incoherent X-ray pulses, and we provide expressions to be used for calculation...... of the experimental diffraction signal for both types of X-ray sources. We present a simple analysis of time-resolved X-ray scattering for direct bond breaking in diatomic molecules. This essentially analytical approach highlights the relation between the signal and the time-dependent quantum distribution...

  12. First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline

    Institute of Scientific and Technical Information of China (English)

    DENG Biao; YANG Qun; XIE Hong-Lan; DU Guo-Hao; XIAO Wi-Qiao

    2011-01-01

    X-ray fluorescence CT is a non-destructive technique for detecting elemental composition and distribution inside a specimen. In this paper, the first experimental results of X-ray fluorescence CT obtained at the SSRF X-ray imaging beamline (BL13W1) are described. The test samples were investigated and the 2D elemental image was reconstructed using a filtered back-projection algorithm. In the sample the element Cd was observed. Up to now, the X-ray fluorescence CT could be carried out at the SSRF X-ray imaging beamline.

  13. Accuracy evaluation of a Compton X-ray spectrometer with bremsstrahlung X-rays generated by a 6 MeV electron bunch

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Sadaoki, E-mail: kojima-s@ile.osaka-u.ac.jp; Arikawa, Yasunobu; Zhang, Zhe; Ikenouchi, Takahito; Morace, Alessio; Nagai, Takahiro; Abe, Yuki; Sakata, Shouhei; Inoue, Hiroaki; Utsugi, Masaru; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Fujioka, Shinsuke; Azechi, Hiroshi [Institute of Laser Engineering, Osaka University, 2-6 Yamada-oka, Suita, Osaka 565-0871 (Japan); Nishimura, Yasuhiko; Togawa, Hiromi [Toyota Technical Development Corporation, 1-21 Imae, Hanamoto-cho, Toyota, Aichi 470-0334 (Japan); Ozaki, Tetsuo [National Institute for Fusion Science, 322-6 Oroshicho, Toki, Gifu 509-5292 (Japan); Kato, Ryukou [The Institute of Science and Industrial Research, Osaka University, 2-6 Yamada-oka, Suita, Osaka (Japan)

    2014-11-15

    A Compton-scattering-based X-ray spectrometer is developed to obtain the energy distribution of fast electrons produced by intense laser and matter interactions. Bremsstrahlung X-rays generated by fast electrons in a material are used to measure fast electrons’ energy distribution in matter. In the Compton X-ray spectrometer, X-rays are converted into recoil electrons by Compton scattering in a converter made from fused silica glass, and a magnet-based electron energy analyzer is used to measure the energy distribution of the electrons that recoil in the direction of the incident X-rays. The spectrum of the incident X-rays is reconstructed from the energy distribution of the recoil electrons. The accuracy of this spectrometer is evaluated using a quasi-monoenergetic 6 MeV electron bunch that emanates from a linear accelerator. An electron bunch is injected into a 1.5 mm thick tungsten plate to produce bremsstrahlung X-rays. The spectrum of these bremsstrahlung X-rays is obtained in the range from 1 to 9 MeV. The energy of the electrons in the bunch is estimated using a Monte Carlo simulation of particle-matter interactions. The result shows that the spectrometer's energy accuracy is ±0.5 MeV for 6.0 MeV electrons.

  14. X-Ray Background from Early Binaries

    Science.gov (United States)

    Kohler, Susanna

    2016-11-01

    What impact did X-rays from the first binary star systems have on the universe around them? A new study suggests this radiation may have played an important role during the reionization of our universe.Ionizing the UniverseDuring the period of reionization, the universe reverted from being neutral (as it was during recombination, the previous period)to once again being ionized plasma a state it has remained in since then. This transition, which occurred between 150 million and one billion years after the Big Bang (redshift of 6 z 20), was caused by the formation of the first objects energetic enough to reionize the universes neutral hydrogen.ROSAT image of the soft X-ray background throughout the universe. The different colors represent different energy bands: 0.25 keV (red), 0.75 keV (green), 1.5 keV (blue). [NASA/ROSAT Project]Understanding this time period in particular, determining what sources caused the reionization, and what the properties were of the gas strewn throughout the universe during this time is necessary for us to be able to correctly interpret cosmological observations.Conveniently, the universe has provided us with an interesting clue: the large-scale, diffuse X-ray background we observe all around us. What produced these X-rays, and what impact did this radiation have on the intergalactic medium long ago?The First BinariesA team of scientists led by Hao Xu (UC San Diego) has suggested that the very first generation of stars might be an important contributor to these X-rays.This hypothetical first generation, Population III stars, are thought to have formed before and during reionization from large clouds of gas containing virtually no metals. Studies suggest that a large fraction of Pop III stars formed in binaries and when those stars ended their lives as black holes, ensuing accretion from their companions could produceX-ray radiation.The evolution with redshift of the mean X-ray background intensities. Each curve represents a different

  15. X-ray in Zeta-Ori

    Science.gov (United States)

    López-García, M. A.; López-Santiago, J. L.; Albacete-Colombo, J. F.; De Castro, E.

    2013-05-01

    Nearby star-forming regions are ideal laboratories to study high-energy emission processes but they usually present high absorption what makes difficult to detect the stellar population inside the molecular complex. As young late-type stars show high X-ray emission and X-ray photons are little absorbed by interstellar material, X-ray dedicated surveys are an excellent tool to detect the low-mass stellar population in optically absorbed regions. In this work, we present a study of the star-forming region Zeta-Ori and its surroundings. We combine optical, infrared and X-ray data. Properties of the X-ray emiting plasma and infrared features of the young stellar objects detected in the XMM-Newton observation are determined. The southern part of the Orion B giant molecular cloud complex harbor other star forming regions, as NGC 2023 and NGC 2024, we use this regions to compare. We study the spectral energy distribution of X-ray sources. Combining these results with infrared, the X-ray sources are classified as class I, class II and class III objects. The X-ray spectrum and ligth curve of detected X-ray sources is analyzed to found flares. We use a extincion-independent index to select the stars with circumstellar disk, and study the relationship between the present of disk and the flare energy. The results are similar to others studies and we conclude that the coronal properties of class II and class III objects in this region do not differ significantly from each other and from stars of similar infrared class in the ONC.

  16. X-ray phase-contrast methods

    Energy Technology Data Exchange (ETDEWEB)

    Lider, V. V., E-mail: lider@ns.crys.ras.ru; Kovalchuk, M. V. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2013-11-15

    This review is devoted to a comparative description of the methods for forming X-ray phase-contrast images of weakly absorbing (phase) objects. These include the crystal interferometer method, the Talbot interferometer method, diffraction-enhanced X-ray imaging, and the in-line method. The potential of their practical application in various fields of science and technology is discussed. The publications on the development and optimization of X-ray phase-contrast methods and the experimental study of phase objects are analyzed.

  17. Two-dimensional x-ray diffraction

    CERN Document Server

    He, Bob B

    2009-01-01

    Written by one of the pioneers of 2D X-Ray Diffraction, this useful guide covers the fundamentals, experimental methods and applications of two-dimensional x-ray diffraction, including geometry convention, x-ray source and optics, two-dimensional detectors, diffraction data interpretation, and configurations for various applications, such as phase identification, texture, stress, microstructure analysis, crystallinity, thin film analysis and combinatorial screening. Experimental examples in materials research, pharmaceuticals, and forensics are also given. This presents a key resource to resea

  18. A Burst Chasing X-ray Polarimeter

    Science.gov (United States)

    Hill, Joanne

    2007-01-01

    This viewgraph presentation reviews the rationale, design, and importance of an X-Ray Polarimeter. There is a brief discussion of Gamma Ray Bursts, followed by a review of the theories of Gamma-Ray Bursts Polarization. This leads to the question of "How do we measure the polarization?" and a discussion of the GRB x-ray emission, the photoelectric effect and photoelectric polarimetry. The requirements for the work, can only be approached using a gas detector. This leads to a discussion of a Micropattern Gas Polarimeter, and the Time-Projection Chamber (TPC) X-ray Polarimeter.

  19. Speckle Scanning Based X-ray Imaging

    CERN Document Server

    Berujon, Sebastien

    2015-01-01

    The X-ray near field speckle scanning concept is an approach recently introduced to obtain absorption, phase and darkfield images of a sample. In this paper, we demonstrate ways of recovering from a sample its ultra-small angle X-ray scattering distribution using numerical deconvolution, and the 2D phase gradient signal from random step scans, the latter being used to elude the flat field correction error. Each feature is explained theoretically and demonstrated experimentally at a synchrotron X-ray facility.

  20. Soft X-Ray Laser Development

    Science.gov (United States)

    1989-10-01

    AND SUBTrI 5. FUNDING NUMBERS Soft X-ray Laser Development 61102F/2301/A8 L AUTHOR(S) ( Szymon Suckewer 7. PERFORMING ORGANIZATION NAME(S) AND ADORESS...REPORT Report of Progress on Soft X-ray Laser Development submitted to Air Force Office of Scientific Research by Acession For DT!C T.IB Princeton...x-ray laser development by Jaegl6 and coworkers 6, however the present work on aluminium plasmas pumped with a low energy Nd laser was primarily