WorldWideScience

Sample records for direct solid-phase radioimmunoassay

  1. Solid phase radioimmunoassays

    International Nuclear Information System (INIS)

    Wide, L.

    1977-01-01

    Solid phase coupled antibodies were introduced to facilitate the separation of bound and free labelled ligand in the competitive inhibition radioimmunoassay. Originally, the solid matrix used was in the form of small particles and since then a number of different matrices have been used such as very fine powder particles, gels, paper and plastic discs, magnetic particles and the inside surface of plastic tubes. The coupling of antibodies may be that of a covalent chemical binding, a strong physical adsorbtion, or an immunological binding to a solid phase coupled antigen. New principles of radioimmunoassay such as the solid phase sandwich techniques and the immunoradiometric assay were developped from the use of solid phase coupled antigens and antibodies. The solid phase sandwich techniques are reagent excess methods with a very wide applicability. Several of the different variants of solid phase techniques are suitable for automation. Advantages and disadvantages of solid phase radioimmunoassays when compared with those using soluble reagents are discussed. (orig.) [de

  2. Differing results of direct and indirect solid phase radioimmunoassay for HBsAg in acute hepatitis

    International Nuclear Information System (INIS)

    Strohm, W.D.; Legler, K.; Gerlich, W.; Stamm, B.; Zimmer, S.; Biotest-Serum-Institut G.m.b.H., Frankfurt am Main; Goettingen Univ.

    1978-01-01

    In 54 patients suffering from active viral hepatitis the indirect solid phase radioimmunoassay (ind-SPRIA) for HBsAg was positive in 9 cases the direct solid phase radioimmunoassay (d-SPRIA) being negative. In 2 further cases ind-SPRIA was positive during several weeks but d-SPRIA only once. AntiHBc could be detected in 9 of these patients. In 7 patients the usual decrease of the transaminase activity was followed by a second elavation with prolongation of the disease. The unknown factor detected by ind-SPRIA suggests a special of acute hepatitis. (orig.) [de

  3. Differing results of direct and indirect solid phase radioimmunoassay for HBsAg in acute hepatitis

    Energy Technology Data Exchange (ETDEWEB)

    Strohm, W D; Legler, K; Gerlich, W; Stamm, B; Zimmer, S [Frankfurt Univ. (Germany, F.R.). Abt. fuer Gastroenterologie; Biotest-Serum-Institut G.m.b.H., Frankfurt am Main (Germany, F.R.); Goettingen Univ. (Germany, F.R.). Hygiene-Institut)

    1978-09-01

    In 54 patients suffering from active viral hepatitis the indirect solid phase radioimmunoassay (ind-SPRIA) for HBsAg was positive in 9 cases the direct solid phase radioimmunoassay (d-SPRIA) being negative. In 2 further cases ind-SPRIA was positive during several weeks but d-SPRIA only once. AntiHBc could be detected in 9 of these patients. In 7 patients the usual decrease of the transaminase activity was followed by a second elavation with prolongation of the disease. The unknown factor detected by ind-SPRIA suggests a special of acute hepatitis.

  4. Direct solid phase radioimmunoassay for chicken lipoprotein lipase

    International Nuclear Information System (INIS)

    Cheung, A.H.; Bensadoun, A.; Cheng, C.

    1979-01-01

    A direct, noncompetitive immunoassay for chicken lipoprotein lipase (LPL) was developed. Antibodies to LPL were purified by immunoadsorption chromatography of goat antisera on an LPL-Sepharose column. Purified anti-LPL immunoglobulins were coupled covalently to hydrophilic polyacrylamide beads by a carbodiimide reagent. An excess amount of these beads was incubated with the sample on the standard to be assayed. The amount of LPL immobilized by the heads was then detected by an excess amount of 125 I-labeled anti-LPL immunoglobulin. A linear relationship was obtained between the radioactivity bound and the amount of highly purified LPL used as a standard. The range of the assay was from 0.1 to 1.1 ng PLP. The assay was specific for chicken LPL and showed no cross-reactivity with liver lipase. It does not distinguish heat-inactivated from catalytically active enzyme species. This assay should be useful in studies of lipoprotein lipase where both catalytic activity and enzyme mass need to be quantitated

  5. Direct solid-phase radioimmunoassay for the detection of Aujeszky's disease antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Doeller, G; Jakubik, J

    1980-06-01

    A direct solid-phase radioimmunoassy (dRIA) was developed in order to demonstrate antibodies against Aujeszky's disease virus (ADV) in sera obtained from pigs and rabbits. In the presence of guinea-pig complement the above test is 160-fold to 1500-fold more sensitive than the neutralization test (NT) and 320-fold to 150 000-fold more sensitive than sera obtained from an ADV-infected farm, which were found to be negative in the complement assisted NT. It is possible to test a single dilution of unknown serum by dRIA by comparing same with a standard curve and to make a statement regarding its ADV-specific binding capacity to /sup 125/I-labelled ADV antigen. The advantages of dRIA in comparison to the indirect RIA and the advantages and disadvantages with regard to ELISA were discussed.

  6. Solid phase tube radioimmunoassay for digoxin detection

    International Nuclear Information System (INIS)

    Stellner, K.; Glatz, C.; Linke, R.

    1975-01-01

    A solid phase radioimmunoassay with 125 I is described for cardiac patients. The test for the digoxin determination and the poisoning due to cardiac glycosides can be measured very accurately and carried out easily. In addition, the test determination can be automatically performed in connection with other tests. (GSE/LH) [de

  7. Development and evaluation of a simple, direct, solid-phase radioimmunoassay of serum cortisol from readily available reagents

    International Nuclear Information System (INIS)

    McConway, M.G.; Chapman, R.S.

    1986-01-01

    A simple, rapid solid-phase radioimmunoassay for serum cortisol was developed using cortisol antibody and commercially available radioiodinated cortisol ligand. The assay involves a 1-h incubation at ambient temperature, using the antibody covalently linked by the easily performed carbonyldiimidazole method, to microcrystalline cellulose. A detailed comparison of the accepted 0.125 mol/l citrate, pH 4.0, and an alternative 0.1 mol/l phosphate/8-anilinonaphthalene sulphonic acid, pH 7.4, diluent demonstrated similar precision and recovery. Phosphate, pH 7.4 diluent was adopted as the diluent of choice, since it was economical of antibody and maintained good precision over a wider working range of cortisol concentration. (Auth.)

  8. Solid phase separation technique for use in radioimmunoassays

    International Nuclear Information System (INIS)

    Tu, J.I.

    1979-01-01

    A radioimmunoassay procedure, and article of manufacture for carrying out that procedure, are disclosed herein. The solid phase separation technique utilized in the radioimmunoassay of this invention utilizes a test tube, the internal surface of which has been coated with two antibody layers

  9. Solid phase radioimmunoassay for HBe Ag and anti-HBe

    Energy Technology Data Exchange (ETDEWEB)

    Froesner, G G; Deinhardt, F [Muenchen Univ. (Germany, F.R.). Inst. fuer Hygiene und Medizinische Mikrobiologie; Sugg, U [Tuebingen Univ. (Germany, F.R.). Abt. fuer Transfusionswesen mit Blutbank; Haas, H [Staedtische Krankenanstalten Esslingen (Germany, F.R.). Zentrallabor; Overby, R L [Abbott Labs., North Chicago, IL (USA)

    1978-04-01

    A highly sensitive solid phase radioimmunoassay for the detection of hepatitis Be-antigen (HBeAg) and anti-HBe is described. Iodine-125 labelled anti-HBe is used as a tracer. The assay is about 500 foLd more sensitive than immunodiffusion.

  10. A solid-phase-radioimmunoassay for total serum thyroxine

    International Nuclear Information System (INIS)

    Moedder, G.; Sokolowski, G.

    1978-01-01

    A new solid phase radioimmunoassay for total serum thyroxine was evaluated over a longer time under clinical routine conditions and compared with an established test system. The results show up that the T 4 values are precise, reliable and reproducible, the is incomplicate to handle and well suitable for semiautomatic pipetting systems. (orig.) 891 MG [de

  11. Solid phase double-antibody radioimmunoassay procedure

    International Nuclear Information System (INIS)

    Niswender, G.D.

    1977-01-01

    The present invention is concerned with the radioimmunoassay (RIA) procedure for assaying body fluid content of an antigenic substance which may either be an antigen itself or a hapten capable of being converted, such as by means of reaction with a protein, to an antigenic material. The present invention is concerned with a novel and improved modification of a double-antibody RIA technique in which there is a first antibody that is specific to the antigenic substance suspected to be present in a body fluid from which the assay is intended. The second antibody, however, is not specific to the antigenic substance or analyte, but is an antibody against the first antibody

  12. Double antibody solid-phase radioimmunoassay for staphylococcal enterotoxin A

    International Nuclear Information System (INIS)

    Lindroth, S.; Niskanen, A.

    1977-01-01

    A double antibody solid-phase (DASP) radioimmunoassay for staphylococcal enterotoxin A is described. In the assay the antigen-antibody complex is precipitated by anti-rabbit serum which is adsorbed onto a solid carrier (cellulose). The method is sensitive to 200 pg of enterotoxin. It was possible to detect a little as 2-5 ng of enterotoxin A/ml food extract from minced meat and sausage. Enterotoxins B and C were not found to inhibit the uptake of labled enterotoxin A at a level which might distort the results of the enterotoxin A assay. The DASP technique is sensitive, rapid, and easy to perform and thus compares favorably with other radioimmunoassays for enterotoxin. (orig.) [de

  13. Solid phase 125I labelled radioimmunoassay for spermidine

    International Nuclear Information System (INIS)

    Zhao Shimin

    1991-01-01

    Using 125 I labelled monoclonal antibody against spermidine and solid phase antigen spermidine-bovine serum albumin conjugate, the radioimmunoassay for spermidine was developed. The sensitivity of this method was about 8 times higher than that of liquid phase 14 C labelled spermidine radioimmunoassay, reaching detection limit of 10 ng/ml (0.5 ng/tube). The working range of standard curve was 0-10 5 ng/ml. The new method was suitable for spermidine measurements in saliva, stomach fluid, and cerebrospinal fluid. The coefficients of variation (CV) of within and between-assay were 4% and 13%, respectively. Preliminary clinical measurements showed that the spermidine levels in saliva of cancer patients and in cerebrospinal fluid of leukemia patients were significantly elevated

  14. New Solid Phases for Estimation of Hormones by Radioimmunoassay Technique

    International Nuclear Information System (INIS)

    Sheha, R.R.; Ayoub, H.S.M.; Shafik, M.

    2013-01-01

    The efforts in this study were initiated to develop and validate new solid phases for estimation of hormones by radioimmunoassay (RIA). The study argued the successful application of different hydroxy apatites (HAP) as new solid phases for estimation of Alpha fetoprotein (AFP), Thyroid Stimulating hormone (TSH) and Luteinizing hormone (LH) in human serum. Hydroxy apatites have different alkali earth elements were successfully prepared by a well-controlled co-precipitation method with stoichiometric ratio value 1.67. The synthesized barium and calcium hydroxy apatites were characterized using XRD and Ftir and data clarified the preparation of pure structures of both BaHAP and CaHAP with no evidence on presence of other additional phases. The prepared solid phases were applied in various radioimmunoassay systems for separation of bound and free antigens of AFP, TSH and LH hormones. The preparation of radiolabeled tracer for these antigens was carried out using chloramine-T as oxidizing agent. The influence of different parameters on the activation and coupling of the used apatite particles with the polyclonal antibodies was systematically investigated and the optimum conditions were determined. The assay was reproducible, specific and sensitive enough for regular estimation of the studied hormones. The intra-and inter-assay variation were satisfactory and also the recovery and dilution tests indicated an accurate calibration. The reliability of these apatite particles had been validated by comparing the results that obtained by using commercial kits. The results finally authenticates that hydroxyapatite particles would have a great potential to address the emerging challenge of accurate quantitation in laboratory medical application

  15. Solid phase radioimmunoassays for human C-reactive protein

    International Nuclear Information System (INIS)

    Shine, B.; Beer, F.C. de; Pepys, M.B.

    1981-01-01

    Two new, rapid and sensitive radioimmunoassays for human C-reactive protein (CRP) have been established using antiserum coupled to magnetizable cellulose particles, which facilitate phase separation. A single antibody method, using solid phase anti-CRP, provides a sensitivity of 50 μg/l with a 1-h incubation time and intra- and inter-assay coefficients of variation of 10%. A double antibody method, using fluid phase rabbit anti-CRP serum and solid phase sheep anti-rabbit IgG serum, provides a sensitivity of 3 μg/l with an overnight incubation and intra- and inter-assay coefficients of variation of 10%. Among 468 sera from normal adult volunteer blood donors the median CRP concentration was 800 μg/l, interquartile range 340-1700 μg/l and range 70-29,000 μg/l. Ninety percent of samples contained less than 3 mg/l and 99% less than 10 mg/l. Low levels (14-650 μg/l) of CRP were detected both in amniotic fluids and in cerebrospinal fluids. (Auth.)

  16. Liquid-phase and solid-phase radioimmunoassay with herpes simplex virus type 1 nucleocapsids

    International Nuclear Information System (INIS)

    Bystricka, M.; Rajcani, J.; Libikova, H.; Sabo, A.; Foeldes, O.; Sadlon, J.

    1985-01-01

    Liquid-phase radioimmunoassay and solid-phase radioimmunoassay are described using 125 I-labelled or immobilized nucleocapsids (NC) of herpes simplex virus (HSV) type1. These techniques appeared sensitive and specific for quantitation of HSV-NC antigens and corresponding antibodies. (author)

  17. Three magnetic particles solid phase radioimmunoassay for T4: Comparison of their results with established methods

    International Nuclear Information System (INIS)

    Bashir, T.

    1996-01-01

    The introduction of solid phase separation techniques is an important improvement in radioimmunoassays and immunoradiometric assays. Magnetic particle solid phase method has additional advantages over others, as the separation is rapid and centrifugation is not required. Three types of magnetic particles have been studied in T 4 RIA and the results have been compared with commercial kits and other established methods. (author). 4 refs, 9 figs, 2 tabs

  18. Solid phase radioimmunoassays using labelled antibodies: a conceptual framework for designing assays

    International Nuclear Information System (INIS)

    Kalmakoff, J.; Parkinson, A.J.; Crawford, A.M.; Williams, B.R.G.

    1977-01-01

    A simple theoretical model for the antigen-antibody reaction is presented and used to evaluate the optimum conditions for designing solid phase radioimmunoassays (RIA) using labelled antibodies. Both theoretical and experimental data are presented, using a wide variety of antigens and their corresponding antibodies. The types of RIA described include the direct, the indirect, the direct sandwich assays for detecting either antigen or antibody. The experimental results confirm in a semiquantitative manner that the greatest sensitivity of the RIA is achieved when the smallest amount of labelled antibody is used, that whenever possible the antigen/antibody ratio should be greater than unity(>1), and that the formation of the antigen-antibody complex is dependent on the mass action effect

  19. Application of solid-phase antibodies to radioimmunoassay

    International Nuclear Information System (INIS)

    McConway, M.G.; Chapman, R.S.

    1986-01-01

    Two types of polymeric microparticle, Dynospheres and reprecipitated acid-hydrolysed nylon 6/6, and two methods of activating these particles with either tresyl chloride or carbonyldiimidazole (CDI) prior to covalent linkage of antibodies were investigated with a view towards their respective adoption for the preparation of general solid-phase reagents for immunoassay applications. Activation of each particle and coupling of antibodies was rapid irrespective of the activator. CDI proved to be the activator of choice since it was cheap, less hazardous, more efficient and less pH dependent than tresyl chloride. Both types of microparticle remain buoyant during the RIA incubation periods and form stable pellets after centrifugation. In second antibody applications immobilisation of the first antibody occurs with a short incubation period of 30 min. Nylon microparticles have a higher antibody-coupling capacity and are the particles of choice in both first and second antibody applications. However, the nylon microparticles possess marginally higher non-specific binding characteristics. (Auth.)

  20. Process for preparation of a solid-phase radioimmunoassay support and use thereof

    International Nuclear Information System (INIS)

    Meriadec, B.; Roubertie, P.

    1979-01-01

    A process is described for the preparation of a support useful in radioimmunoassay chromatographic columns. The process involves the preparation of a chromatographic gel capable of selectively retaining one or more components contained in an antigen-antibody-containing solution. The gel is bound to the appropriate antiserum, then freeze-dried, pulverized and compressed into a tablet. The tablet support swells upon contact with an antigen-antibody-containing solution to conform to the shape of the columns. An example of the application of this support in the radioimmunoassay of thyroid-stimulating hormone is described. This type of support is also particularly useful in second antibody solid phase radioimmunoassays since there is no limit to the size of the antigen to which this technology may be applied. (U.K.)

  1. Application of a sepharose bead immunofluorescence assay and a solid-phase radioimmunoassay to the bovine leukemia virus system

    International Nuclear Information System (INIS)

    Fiebach, H.; Uckert, W.; Micheel, B.

    1982-01-01

    Several fluorescence assays with bovine leukemia virus (BLV) conjugated to activated Sepharose 4B were used for the detection of BLV and anti-BLV antibodies. These tests were compared with a solid-phase radioimmunoassay and found to be in the same sensitivity range. Sepharose bead immunofluorescence assay and solid-phase radioimmunoassay can be applied to the diagnosis of BLV infection in cattle. (author)

  2. Application of a sepharose bead immunofluorescence assay and a solid-phase radioimmunoassay to the bovine leukemia virus system

    Energy Technology Data Exchange (ETDEWEB)

    Fiebach, H.; Uckert, W.; Micheel, B. (Akademie der Wissenschaften der DDR, Berlin. Zentralinstitut fuer Krebsforschung)

    Several fluorescence assays with bovine leukemia virus (BLV) conjugated to activated Sepharose 4B were used for the detection of BLV and anti-BLV antibodies. These tests were compared with a solid-phase radioimmunoassay and found to be in the same sensitivity range. Sepharose bead immunofluorescence assay and solid-phase radioimmunoassay can be applied to the diagnosis of BLV infection in cattle.

  3. The development of a general solid-phase radioimmunoassay method. Application to follicle stimulating hormone and to luteinizing hormone radioimmunoassays

    International Nuclear Information System (INIS)

    Fleury, B.

    1981-10-01

    A solid phase method of radioimmunoassay utilizing a second antibody adsorbed onto tubes was developed. Polyethylene tubes were selected for their adsorption capacity. The following topics were emphasized: the rate of labelled antigen uptake on the second antibody adsorbed on the tubes through the medium of the first antibody; the influence of the second antibody on the antigen-first antibody reaction and comparison with the immunoprecipiting technique; the various factors able to influence the calibration curve and applications to assay optimization; the performances of hFSH AND hLH assays [fr

  4. A competitive solid-phase radioimmunoassay for quantitation of the major allergen of Parietaria pollen

    International Nuclear Information System (INIS)

    Corbi, A.L.; Ayuso, R.; Lombardero, M.; Duffort, O.; Carreira, J.

    1985-01-01

    A competitive solid-phase radioimmunoassay has been developed for quantitation of the major allergen of Parietaria judaica pollen. The assay is based on: (1) the ability of AC/1.1 monoclonal antibody to bind specifically to the P. judaica major allergen, and (2) the ability of crude pollen extracts or purified allergen to inhibit the binding of 125 I-labelled allergen to solid-phase-bound AC/1.1 monoclonal antibody. The assay is sensitive enough to detect as little as 10 ng of allergen. A good correlation is found when the results obtained are compared with those produced by RAST inhibition (r = 0.95; P < 0.001). Thus, this method can also be used for the estimation of the allergenic activity of P. judaica pollen extracts. The assay is easily completed in 2 h, allowing simultaneous analysis of a number of extracts. (Auth.)

  5. Solid-phase radioimmunoassay of immunoglobulins G, A and M: applicability in analysis of sucrose gradients

    Energy Technology Data Exchange (ETDEWEB)

    Eriksen, E F; Danielsen, H [Aarhus Kommunehospital (Denmark). Medical Department C; Johansen, A S [Aarhus Univ. (Denmark). Institute of Medical Biochemistry; Larsson, L I [Unit of Histochemistry, University Institute of Pathology, Copenhagen, Denmark

    1984-01-01

    A simple and sensitive solid-phase radioimmunoassay for the detection of immunoglobulins G, A and M in sucrose gradients is described. The solid-phase consisted of immunoglobulins adsorbed to polystyrene tubes. Using buffers without detergent and /sup 125/I-labeled sheep anti-rabbit IgA as radioligand, the assay was able to detect 0.8 ng per tube in the IgG assay and 1.6 ng per tube in the IgA and IgM assays. Standard curves with antigen dissolved in 10% and 32% sucrose were superimposable and did not deviate from standard curves with antigen dissolved in buffer without sucrose. Using these techniques on ultracentrifugation samples from patients with systemic lupus erythematosus, Schoenlein-Henoch nephritis and IgA glorulonephritis is was possible to detect both immunoglobulin fragments and immunoglobulin aggregates at the same time without prior dialysis of the samples.

  6. Development of a solid phase technic for radioimmunoassay of triiodothyronine (T3) in serum

    International Nuclear Information System (INIS)

    Hamada, M.M.; Mesquita, C.H.; Silva, C.P.G. da.

    1988-10-01

    We have developed a solid phase radioimmunoassay (RIA) system for triiodothyronine (T 3 ), by immobilizing triiodothyronine antibodies on the inner wall of reaction tubes. The antibody-coated tubes were made via reaction of antibody with glutaraldeyde residue pre coated on the inner wall of the tubes by alkaline self-polimerization. The quality of the coated tubes was tested through its performance in the RIA methodology, by analysing the following RIA parameters: minimum detectable dose (MDD), nonspecific binding (NSB), ''X 50% '', slope of the standard curve, intra and inter-assay precision, accuracy of the method and figure of merit. The serum levels of T 3 in hypothyroid and hyperthyroid patients and the normal values range were determined for the solid phase RIA system. The results are in agreement with found in the literature. (author) [pt

  7. A new solid-phase sandwich radioimmunoassay and its application to the detection of snake venom

    International Nuclear Information System (INIS)

    Coulter, A.R.; Cox, J.C.; Sutherland, S.K.; Waddel, C.J.

    1978-01-01

    A solid-phase sandwich radioimmunoassay is described which can be used for the detection and quantitative estimation of crude snake venom and a snake neurotoxin in clinical and experimental situations. Rabbit IgG antivenom or antineurotoxin, covalently coupled to a solid phase (CH-Sepharose 4B) is incubated with sample of unknown venom concentration. Venom bound by the solid-phase antibody is detected by reaction with 125 I-labelled rabbit IgG antivenom or antineurotoxin ([ 125 I]IgG). The resultant count, T, is the total (specific and non-specific) uptake of [ 125 I]IgG. Non-specific binding N, is similarly determined, but with normal rabbit IgG antivenom or antineurotoxin ([ 125 I]IgG). The resultant count, T, is the total (specific and non-specific) uptake of [ 125 I]IgG. Non-specific binding N, is similarly determined, but with normal rabbit IgG bound to the solid phase. A T:N value greater than 1.8 for human serum or urine indicates the presence of venom in a sample (P>0.95). Positive samples are assayed at several dilutions and the venom present estimated from the specific count (T-N). Levels of 0.4 ng/ml of crude tiger snake venom (TSV) and 0.1 ng/ml of neurotoxin can be reliably detected by this procedure. (Auth.)

  8. Detection and specifity of class specific antibodies to whole bacteria cells using a solid phase radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Czerkinsky, C.; Rees, A.S.; Bergimeier, L.A.; Challacombe, S.J. (Guy' s Hospital Medical and Dental Schools, London (UK))

    1983-07-01

    A solid phase radioimmunoassay has been developed which can be used for the detection of isotype specific antibodies to whole bacteria and other particulate antigens, and is applicable to a variety of species. Bacteria are bound to the solid phase by the use either of antibodies, or of methyl glyoxal. Both methods result in a sensitive and reproducible assay, and bacteria do not appear to desorb from the solid phase. The specificity of antibodies to whole bacteria was examined by absorption of antisera with various species of bacteria and retesting, or by determining the binding of antisera to various bacteria bound to the solid phase. Both methods revealed specificity for the bacteria examined. Inhibition studies showed that antibodies to Streptococcus mutans whole cells could be inhibited by purified cell surface antigens glucosyltransferase and antigen I/II, but only minimally by lipoteichoic acid, c polysaccharide or dextran. In murine antisera antibodies of the IgG, IgM, and IgA classes could be detected at amounts of less than 1 ng/ml.

  9. Solid Phase Radioimmunoassay for Measuring Serum Prolactin Using Antibody Coupled Magnetizable Particles

    International Nuclear Information System (INIS)

    El-Bayoumy, A.S.A.

    2012-01-01

    The objective of the present work was to prepare solid phase radioimmunoassay (RIA) reagents. Development as well as optimization and validation of RIA system using solid phase magnetic particles for the measurement of prolactin (PRL) in human serum are described. The production of polyclonal antibodies was carried out by immunizing three Balb/C mice intraperitoneal through primary injection and two booster doses. Low density magnetizable cellulose iron oxide particles have been used to couple covalently to the IgG fraction of polyclonal anti-prolactin using carbonyl diimidazole activation method and applied as a solid phase separating agent for RIA of serum prolactin. Preparation of 125 I-PRL tracer was prepared using lactoperoxidase method and it was purified by gel filtration using sephadex G-100. The PRL standards were prepared using a highly purified PRL antigen with assay buffer as standard matrix. Optimization and validation of the assay were carried out. The results obtained provide a low cost, simple, sensitive, specific and accurate RIA system of prolactin based on magnetizable solid phase separation. These magnetic particles retain their characteristics during storage for 6 months at 4 degree C. In conclusion, this assay could be used as a useful diagnostic tool for pituitary dysfunction and possible reproductive disability.

  10. Radioimmunoassay of diagoxin with the aid of the solid phase - microtitre plating technique

    International Nuclear Information System (INIS)

    Scheidt, C.

    1982-01-01

    Preliminary results are reported here on the development of a digoxin-radioimmunoassay with an anti-digoxin antibody (goat) in a solid phase technique (mictrotitre plate). The advantages compared to conventional RIAs are: Cross reactions towards digoxin is minimal, both in vitro and in vivo. The calibraton range extends from 0.25 to 8 ng/ml. The radioactive load could be reduced significantly by use of smaller amounts of tracer (0.004 μCi/single determination) and by reduction of waste volume (solid), waste weight (solid) and liquid waste. The DIGOXIN RIA BIOTEST MTP is, in addition, the only digoxin radioimmunoassay where radioactive waste is produced in a sealed form. The test is a simple one and can be carried out without the need for complicated apparatus and techniques. (orig./MG) [de

  11. A solid phase radioimmunoassay for free triiodothyronine in serum: assay development and validation

    International Nuclear Information System (INIS)

    Liu Fangyan; Zhou Meiying; Yin Linxiang; Yang Jianzhong; Hua Chenglin

    1999-01-01

    A solid phase radioimmunoassay for free triiodothyronine in serum was developed based on double-antibody coated tubes. The method was turned out to be reliable with good reproducibility, higher sensitivity and easy performance. The measurable range of FT 3 in serum was 1.2 to 38 pmol/L. The mean coefficients of variation within and between assays were 1.79%∼3.18% and 4.72%∼9.31%, respectively. The FT 3 concentrations in euthyroid serum as determined by this method were 2.8 to 7.8 pmol/L. The FT 3 values determined by this new method correlated well with those measured by a commercial radioimmunoassay (r = 0.853)

  12. New solid phase radioimmunoassay (CLB-RIA) for the detection of hepatitis-B antigen and antibody

    Energy Technology Data Exchange (ETDEWEB)

    Duimel, W J [Centraal Laboratorium van de Bloedtransfusiedienst, Amsterdam; Brummelhuis, H G.J.

    1975-07-01

    A new competitive solid phase radioimmunoassay (CLB-RIA) has been developed for the detection of HBAg and HBAb in human serum and plasma. In the assay, sheep antibodies to HBAg, covalently linked to an insoluble carrier, highly purified /sup 125/I labelled HBAg and the serum or plasma sample are incubated for 20 h at room temperature. After incubation, the bound and the free fraction of the tracer are separated by centrifugation. The presence of both HBAg and HBAb results in a decrease of the amount of bound tracer, when compared with a negative control serum. Differentiation between HBAg and HBAb requires the use of another type of radioimmunoassay. For this purpose a sandwich solid phase radioimmunoassay, for the detection of HBAb only, has been developed (CLB-AURIA). In this, assay-purified HBAg is covalently linked to an insoluble carrier. Using a mixture of both immunosorbents (insolubilized HBAg and HBAb), it is possible to detect and to distinguish HBAg and HBAb in one single solid phase radioimmunoassay (CLB-MIRIA). The influence of three parameters on the CLB-RIA, the incubation time, the amount of tracer and the effect of Tween-20 has been studied. The sensitivity of the described solid phase CLB-RIA for the detection of HBAg is comparable to that of other radioimmunoassays reported in literature; its specificity is very high.

  13. Studies on Purification and Coatation of Polyclonal Antibody for Prolactin Solid Phase Radioimmunoassay in Human Serum

    International Nuclear Information System (INIS)

    El-Bayoumy, A.S.A.; Sallam, Kh.M.; Shafik, H.M.

    2012-01-01

    The objective of the present study was oriented to produce purified polyclonal antibody to prepare a prolactin solid phase coated tubes radioimmunoassay system. In the present study, production of polyclonal antibodies was carried out through immunization of three healthy white male mature New Zealand rabbits with a highly purified sheep prolactin antigen. The obtained anti-sera was purified using an anion exchange reactive group, diethylamino ethyle (DEAE) covalently linked to Sepharose. The purified polyclonal antibody was used for coating polystyrene tubes. The preparation of 125 I-prolactin tracer was carried out using chloramine-T method. The preparation of standards was performed using assay buffer to cover the range from 2 to 200 ng/ml. The optimization and validation tests of the assay were performed to evaluate the validity of the prepared system. In conclusion, this low cost assay would be used in diagnosis of pituitary dysfunction and diagnosis of infertility in males and females

  14. Development Of Radioimmunoassay For Prolactin HORMONE Using Solid Phase Magnetic Particles

    International Nuclear Information System (INIS)

    SHAFIK, H.M.; MEHANY, N.L.

    2009-01-01

    The preparation and development of primary reagents of prolactin (PRL) radioimmunoassay (RIA) technique using solid phase magnetic particles with low cost is considered to be the main objective of the present study. The production of polyclonal antibodies was undertaken by immunizing four female New-Zealand rabbits through primary injection and four booster doses subcutaneously. The preparation of 125 I-prolactin radiotracer was carried out using chloramine-T. The preparation of standard prolactin was undertaken by preparing stock standard solution of prolactin and diluted with assay buffer. Activation and coupling of low magnetizable particles with the purified anti-PRL was carried out. Optimization and validation of the assay were carried out. The results obtained provide a highly sensitive, specific and accurate RIA system of PRL. In conclusion, this assay could be used in diagnosis of galactorrhea, prolactinoma, visual impairment and diagnosis of infertility in males and females.

  15. Studies on Purification and Coatation of Polyclonal Antibody for Prolactin Solid Phase Radioimmunoassay in Human Serum

    International Nuclear Information System (INIS)

    El-Bayoumy, A.S.A.; Sallam, Kh.M.; Shafik, H.M.

    2014-01-01

    The objective of the present study was oriented to produce purified polyclonal antibody to prepare a prolactin solid phase coated tubes radioimmunoassay system. In the present study, production of polyclonal antibodies was carried out through immunization of three healthy white male mature New Zealand rabbits with a highly purified sheep prolactin antigen. The obtained anti-sera was purified using an anion exchange reactive group, diethylamino ethyle (DEAE) covalently linked to Sepharose. The purified polyclonal antibody was used for coating polystyrene tubes. The preparation of 125 I-prolactin tracer was carried out using chloramine-T method. The preparation of standards was performed using assay buffer to cover the range from 2 to 200 ng/ml. The optimization and validation tests of the assay were performed to evaluate the validity of the prepared system. In conclusion, this low cost assay would be used in diagnosis of pituitary dysfunction and diagnosis of infertility in males and females.

  16. Simultaneous measurement of thyroxine and triiodothyronine in trout plasma using a solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Omeljaniuk, R.J.; Cook, R.F.; Eales, J.G.

    1984-01-01

    A solid-phase radioimmunoassay (RIA) employing miniature G-25 Sephadex columns and a single isotope was evaluated for simultaneous measurement of T 3 (3,5,3'-triiodo-L-thyronine) and T 4 (L-thyroxine) in trout plasma. The method was judged reliable based on the characteristics of the standard curves, the high and consistent recoveries of T 3 (87.0 or 86.7 percent) and T 4 (103 or 98 percent) added either singly or in combination, low inter-( 3 and T 4 after plasma dilution, and acceptable correlations between hormone values obtained using either the simultaneous or single RIA methods (rsub(T3) = 0.89; rsub(T4) = 0.91). It is concluded that the simultaneous RIA with its savings in time, plasma volume, and reagents can be used to advantage to measure T 3 and T 4 in plasma of trout and presumably other vertebrates

  17. Analysis of a solid-phase radioimmunoassay for antibodies to cytoplasmic antigen fractions of Candida albicans

    International Nuclear Information System (INIS)

    Mauch, H.; Bromback, J.

    1981-01-01

    An indirect solid-phase radioimmunoassay (SPRIA) in individual polystyrene microtiter cups has been adapted for measurement of antibody to various cytoplasmic and carbohydrate antigen fractions of Candida albicans. The assay was optimized for sensitivity, precision and linearization of serum dilution curves. The optimized procedure allows computerized measurement of anti-Candida antibodies and can be used for measurement of antibody over a wide concentration range. The procedure obviates variation due to changes in day-to-day counts as a result of isotope decay and end-point antibody dilutions. The assay has been used to demonstrate a Poisson-like distribution of antibody levels in the sera of persons showing no symptoms of candidiasis. The minimum antibody level detectable by the assay is about two orders of magnitude lower than the lowest level found in human serum and 4 orders of magnitude lower than the most sensitive test used hitherto, the hemagglutination test. (Auth.)

  18. Quantitation of complement factor D in human serum by a solid-phase radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Barnum, S R; Niemann, M A; Kearney, J F; Volanakis, J E [Alabama Univ., Birmingham (USA)

    1984-03-16

    A sensitive solid-phase radioimmunoassay is described which quantitates human D to 1-2 ng/ml. The assay was used to measure the concentration of D in normal and acute-phase sera and sera from individuals with systemic lupus erythematosus. All 3 groups of sera had comparable levels of D with mean values of 1.8, 2.3 and 2.5 ..mu..g/ml, respectively. Also tested were sera decomplemented in vitro by activators of the classical and alternative pathways. The results indicated that D is not depleted by alternative or classical pathway activation. However, heat inactivation (56/sup 0/C, 30 min) of serum resulted in almost complete loss of antigenic D.

  19. Micro solid-phase radioimmunoassay for detection of herpesvirus type-specific antibody: parameters involved in standardization

    Energy Technology Data Exchange (ETDEWEB)

    Matson, D.O.; Adler-Storthz, K.; Adam, E.; Dreesman, G.R. (Baylor Univ., Houston, TX (USA). Coll. of Medicine)

    1983-02-01

    A micro solid-phase radioimmunoassay (micro-SPRIA) was developed to demonstrate type-specific antibodies to herpes simplex virus types 1 and 2 (HSV1 and HSV2). Glycoproteins from the 123,000 dalton region of HSV1 (VP123) and the 119,000 dalton region of HSV2 (VP119) were isolated on preparative polyacrylamide gels for use as antigens in the micro-SPRIA. Human sera selected from clinical samples by virological history and appropriate microneutralization data were used to standardize the micro-SPRIA. Optimization of the assay required the use of siliconized microtiter wells for adsorption of antigen. Maximized results were highly dependent on the concentrations of antigen, primary antibody, and secondary antibody as well as the diluents used for these principal test reagents. Incorporation of HSV glycoproteins of each respective type with the optimal condition established in this study facilitates the direct detection of type-specific antibody in human sera.

  20. Development and evaluation of a magnetic solid-phase radioimmunoassay for total human thyroxine (T4)

    International Nuclear Information System (INIS)

    Abbas, S. H.; Hassan, A. M. E.; Abdalla, O. M.; Zahran, A. B.; Shabbo, N. M.; Ali, N. I.; Gubara, A.

    2009-02-01

    In this study a simple and rapid magnetic solid-phase radioimmunoassay (RIA) for human thyroxine (T4) was developed using locally raised sheep thyroxine antibody and radioiodinated thyroxine (T4) tracer by chloramine-T method. The assay involves two hours incubation at ambient temperature rang (30 to 35 o C ) associated with the antibody covalently linked by the easily performed carbonyldiimidazole (CDI) method to magnetic particles obtained from SIPAC. 0.1% triton with sodium azide used as a wash buffer. L-Thyroxine Na-salt peta hydrate from sigma was used for the preparation of standards and quality control sera. The coupled magnetic anti-T4 solid phase titrated in order to find out the suitable antibody concentration (titre) to be used in the assay. Optimizations followed by validation procedures were done. When correlated with kits imported from NETRIA and AMERSHAM, results were found to be highly comparable r=0.965 and p<0.05. Shelf life was also studied, so that the local prepared T4 RIA magnetic reagents can be used for the measurement of total human thyroxine with a very low cost compared to imported kits. (Author)

  1. Production and Characterization of Anti-LH Polyclonal Antibodies for Establishment of Sepharose Solid Phase Radioimmunoassay

    International Nuclear Information System (INIS)

    Ebeid, N.H.; Mehany, N.L.

    2016-01-01

    The present study was designed to achieve the production and characterization of polyclonal antibody of luteinizing hormone (Anti-LH) as a basic component of LH radioimmunoassay (RIA). The main objective was to improve the immunogenicity of LH by conjugation of LH with bovine serum albumin (LH: BSA) as a protein carrier using Ethyl dimethylaminopropyl Carbodiimide (ECDI). Production of Anti-LH was described where LH : BSA immunogen was immunized into three male mature white New-Zealand rabbits through primary immunization and four boosters. The criteria for selecting LH antiserum for liquid phase RIA system were mainly titer, displacement and immuno response profile and followed by partial purification of IgG-LH. The radioiodinated 125 I-LH tracer was carried out using Chloramine-T as an oxidizing agent and the tracer was purified through PD-10 column. The preparation of LH standards was carried out. Coupling of purified IgG-LH to activated Sepharose particles CL-4B was carried out after activation of Sepharose particles with 1,1-carbonyldiimidazole. Extensive studies were carried out to obtain the optimum conditions of using solid phase Sepharose particles to reach the optimum separation efficiency. The results of validation tests revealed that the local solid phase RIA system is precise and accurate to detect LH concentration in human serum to be used as a diagnostic tool in investigating the infertility in the hypothalamic pituitary gonadal disorders

  2. Applications of a solid phase radioimmunoassay (SPRIA) to the micro-determination of ABO blood group

    International Nuclear Information System (INIS)

    Wu Fenqiang; Guo Jingyuan

    1995-01-01

    The authors report a simple, rapid, sensitive and accurate solid phase radioimmunoassay (SPRIA) method which has been improved. The research included the tests of its methodological parameters, sensitivity, accuracy, and the studies on its applications to the detection of blood group substances in varied forensic biological materials. The coefficient variation of intra-assay was 5.6%, and that of inter-assay was 10.15%. As to its applications to the forensic serology, the ABO blood groups of human bloodstain, hair follicular tissues and salivary stains had been tested and the results were satisfying. Later, 50 unknown type bloodly samples had been blind tested. The judging level used to identify the positive and negative wells was 800 cpm, that meant, if the radioactive count of a well were over 800 cpm, it was determined as a positive well, if that of a well were below 800 cpm, it was negative well. As SPRIA is a method of micro-determination which can micro-test the blood group antigens contained in varied forensic biological materials, it should has a good future of its applications to the forensic medicine fields

  3. Rubella serology by solid-phase radioimmunoassay: its potential for screening programmes

    International Nuclear Information System (INIS)

    Sugishita, C.; O'Shea, S.; Best, J.M.; Banatvala, J.E.

    1978-01-01

    Sera from 269 adult females who had experienced naturally acquired or vaccine-induced infection by rubella virus, including immune persons challenged intranasally with rubella vaccine (RA27/3) as well as sera from 100 patients attending antenatal clinics, were tested for rubella antibodies by the conventional haemagglutination inhibition tests (HAI), as well as a newly developed solid-phase radioimmunoassay (RIA) for rubella immunoglobulin G(IgG) antibodies. Following both naturally acquired and vaccine-induced infection, titres by RIA were approximately ten-fold higher than by HAI. The RIA test was particularly useful in assessing the true immune status of those with apparently low levels of HAI antibody and has the added advantage that pretreatment of sera to remove inhibitors of haemagglutination and red cell agglutinins is unnecessary. The RIA test has potential for the large-scale screening programmes which need to be carried out if the Department of Health and Social Security recommendation, that women attending antenatal and family planning clinics be screened for rubella antibodies, is to be effectively met. (author)

  4. Solid phase radioimmunoassay for detection of malaria antigen. Comparison of monoclonal and polyclonal antibodies

    International Nuclear Information System (INIS)

    Khusmith, S.; Tharavanij, S.; Patarapotikul, J.; Kasemsuth, R.; Bunnag, D.

    1986-01-01

    A solid phase competitive binding radioimmunoassay (RIA) was developed for the detection of Plasmodium falciparum in infected blood. A suspension of NP40 treated red blood cells was mixed with labelled antimalarial IgG, incubated and then added to malarial antigen coated microtitre plate. Antimalarial IgGs were purified either from high titre sera from individuals living in a malaria endemic area in Thailand or from a locally produced monoclonal antibody (MAB) which showed a bright generalized immunofluorescent staining pattern against all blood stages of P. falciparum, including gametocytes. This MAB reacted with 27 of 31 P. falciparum isolates from Thailand. Using dilution of red blood cells from in vitro cultures of P. falciparum, the test was found to detect parasites at levels equivalent to 13 and 2.2 parasites/10 6 red blood cells with labelled polyclonal IgG (PIgG) and labelled monoclonal IgG (MIgG), respectively. No false positive results were obtained among samples from non-malarial subjects. Of the samples that gave negative results upon microscopic examination, 50 and 35% were still positive with RIA using MIgG and PIgG, respectively. There was a correlation between RIA and the number of parasites, especially when MIgG was used. The results indicate that the IgG fraction of sera from individuals with natural acquired immunity to malaria showed a lower degree of sensitivity in parasite detection than the IgG from monoclonal antibody. (author)

  5. Micro solid-phase radioimmunoassay for detection of herpesvirus type-specific antibody: specificity and sensitivity

    Energy Technology Data Exchange (ETDEWEB)

    Adler-Storthz, K.; Matson, D.O.; Adam, E.; Dreesman, G.R. (Baylor Univ., Houston, TX (USA). Coll. of Medicine)

    1983-02-01

    The specificity and sensitivity of a micro solid-phase radioimmunoassay (micro-SPRIA) that detects type-specific IgG antibody to herpes simplex virus types 1 and 2 (HSV1 and HSV2) were evaluated. Glycoproteins VP123 (molecular weight, 123,000) of HSV1 and VP119 (molecular weight, 119,000) of HSV2 were found to display the greatest degree of antigenic type-specificity of several HSV antigens tested with the micro-SPRIA technique. When testing a group of sera, negative for anti-HSV antibodies by microneutralization, in the micro-SPRIA, a range of negative reactivities was noted, suggesting that cut-points should be determined for each antigen preparation. The micro-SPRIA detected appropriate antibody activity in patients with recurrent infection and a marked agreement was noted in comparison to detection of anti-HSV antibodies measured with the microneutralization test. The type-specificity of the micro-SPRIA was substantiated by the independence of test results using VP119 and VP123 antigens for a random group of positive sera. The assay is rapid, specific, and sensitive and allows the testing of multiple serum samples with a standardized set of reagents.

  6. Solid phase radioimmunoassay for detection of serum autoantibodies in systemic lupus erythematosus

    Energy Technology Data Exchange (ETDEWEB)

    Smith, K O; Harrington, J T; Gehle, W D

    1977-03-01

    Solid phase radioimmunoassay (RIA) methods for measuring autoantibodies in systemic lupus erythematosus (SLE) patients' serum were developed to improve the sensitvity and quantitative precision of the determinations. Two mechanical systems were studied: (1) acetone fixed cell monolayers in glass tubes and (2) antigen coated plastic beads. Both systems were senssitive and reproducible. The most sensitive, versatile system involves the coating of the plastic beads with nuclear antigen(s), incubation overnight with sera and labelling with /sup 125/I conjugated antihuman globulin. Linear binding of this radioactive tag is obtained over a wide range of SLE serum dilutions and the slopes of the serum dilution titration curves are almost identical for all SLE patients' sera tested. Therefore, a standard titration curve can be constructed from the results with a positive serum, and end-point dilutions of unknown sera estimated from results obtained with a single serum dilution. Alternatively, binding ratios of unknown sera can be usefully compared at fixed dilutions with standard positive and negative sera. For example, high binding ratios (>3.0) were obtained with 19/20 SLE sera and 0/20 control sera. Antigens used in these systems include crude, whole-cell lysates and lysates from purified nuclei.

  7. Anti-glomerular basement membrane autoantibodies in the Brown Norway rat: detection by a solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Bowman, C.; Peters, D.K.; Lockwood, C.M.

    1983-01-01

    A solid-phase radioimmunoassay (RIA) is described for the detection of IgG autoantibodies to glomerular basement membrane (GBM) induced in the Brown Norway rat by mercuric chloride. The assay involves the adsorption of a collagenase digest of GBM to plastic microtitre plates and detection of bound antibody with affinity purified radiolabelled rabbit anti-rat IgG. Comparison with existing immunofluorescence methods for detection of anti-GBM antibody showed that the solid-phase RIA is highly sensitive, allowing detection of antibody in solutions with as low as 0.5 ng protein/ml. The assay is suitable for detection of anti-GBM antibody both in serum and in eluates from nephritic kidneys. The assay proved to be specific in competitive studies of inhibition brought about by GBM, keyhole limpet antigen and ovalbumin. This solid-phase RIA is reproducible, robust and easy to perform. (Auth.)

  8. Solid-phase radioimmunoassay for the detection fo IgG antibodies to gramineae pollen (Dactylis glomerata) and to acarida (dermatophagoides Pteronyssinus)

    Energy Technology Data Exchange (ETDEWEB)

    Guilloux, L.; Ville, G.

    1985-01-01

    A solid-phase radioimmunoassay using SVI-protein A onto polystyrene microplates, was applied successfully for the detection of IgG antibodies to acarida and to grass pollen in allergic patients and in patients undergoing desensitization therapy.

  9. Solid phase radioimmunoassay for plasma testosterone using a plastic microtiter tray

    International Nuclear Information System (INIS)

    Hosogi, Hidemi

    1975-01-01

    In order to simplify radioimmunoassay for plasma testosterone and to measure many samples at the same time, a method of solid phase radioimmunoassay utilizing a plastic disposable microtiter tray (DMT) by which chromatography can be omitted was investigated. Other steroids except for 5α-dihydrotestosterone (5α-DHT) had a low degree of cross reactivity with the antiserum. Five α-DHT which could be measured together with testosterone in this assay was not a problem clinically because of its strong androgenic activity. The best standard curve was obtained when the antiserum was diluted to 1:1000. The sensitivity of this assay was 10 pg-tube. The maximal adsorption of antibody to plastic DMT was observed when the pH of the antiserum was within the range of 6.5-9.5 and the precoating time was 24 hr at room temperature. The best pH of the incubation buffer was 0.8, and the antigen-antibody reaction became a plateau when the incubation exceeded 6 hrs. The water blank in this assay was 4.6 +- 2.1 pg/tube. The recovery of testosterone (50, 100, 200 pg) when added to 0.1 ml female plasma was 99 +- 6.8%. Coefficients of variation within assay and between assays were below 11.2% and 20.0%, respectively. Correlation between this method and the dextran-coated charcoal method was fairly good (r=0.938). Plasma testosterone levels in 10 normal males and 12 normal females were 616 +- 202 (mean +- SD) ng/dl and 66 +- 29 (mean +- SD) ng/dl, respectively. The levels were low in patients with hypopituitarism, hypogonadism and acromegaly. They were normal in patients with Cushing's syndrome due to adrenal hyperplasia and adenoma, but they were high in a patient with adrenal carcinoma. In a patient with testicular feminization, the level was 632 ng/dl. This increased after the administration of HCG, and decreased to 127.5 ng/dl after castration. (auth.)

  10. A simple solid-phase radioimmunoassay for the measurement of IgG secreted in vitro by human lymphocytes

    International Nuclear Information System (INIS)

    Romagnani, S.; Prete, G.F. del; Giudizi, G.M.; Almerigogna, F.; Ricci, M.

    1979-01-01

    A radioimmunoassay is described for measuring IgG, based on the ability of immunoglobulins of this class to inhibit the binding of radioiodinated staphylococcal protein A to IgG linked to a solid phase. The solid phase is represented by ox erythrocytes coated with anti-ox erthrocyte rabbit IgG, a reagent used for detecting cells equipped with receptors for the Fc fragment of IgG. By this assay the IgG secreted in vitro by human peripheral blood lymphocytes stimulated with PWM and those present in samples of very diluted human sera were measured. It was found that the assay is a very rapid, simple and and reproducible procedure for the detection of IgG immunoglobulin at the nanogram level. (Auth.)

  11. The detection and specifity of class specific antibodies to whole bacteria cells using a solid phase radioimmunoassay

    International Nuclear Information System (INIS)

    Czerkinsky, C.; Rees, A.S.; Bergimeier, L.A.; Challacombe, S.J.

    1983-01-01

    A solid phase radioimmunoassay has been developed which can be used for the detection of isotype specific antibodies to whole bacteria and other particulate antigens, and is applicable to a variety of species. Bacteria are bound to the solid phase by the use either of antibodies, or of methyl glyoxal. Both methods result in a sensitive and reproducible assay, and bacteria do not appear to desorb from the solid phase. The specificity of antibodies to whole bacteria was examined by absorption of antisera with various species of bacteria and retesting, or by determining the binding of antisera to various bacteria bound to the solid phase. Both methods revealed specificity for the bacteria examined. Inhibition studies showed that antibodies to Streptococcus mutans whole cells could be inhibited by purified cell surface antigens glucosyltransferase and antigen I/II, but only minimally by lipoteichoic acid, c polysaccharide or dextran. In murine antisera antibodies of the IgG, IgM, and IgA classes could be detected at amounts of less than 1 ng/ml. (author)

  12. Development of solid phase radioimmunoassay using antibody coupled magnetizable particles for measurement of progesterone in human serum

    International Nuclear Information System (INIS)

    Mehany, N.L.

    2007-01-01

    The aim of the present study was to prepare solid phase radioimmunoassay (RIA) reagents. Development as well as optimization and validation of RIA system using solid phase magnetic particles for the measurement of progesterone in human serum are described. The production of polyclonal antibodies was carried out by immunizing five white New-Zealand rabbits subcutaneously. Low density magnetizable cellulose iron oxide particles have been used to couple covalently to the IgG fraction of polyclonal anti-progesterone using carbonyl diimidazole activation method and applied as a solid phase separating agent for RIA of serum progesterone. 125 I-progesterone tracer was prepared using chloramine-T and iodogen oxidation methods and purified using high performance liquid chromatography. The progesterone standards were prepared using highly purified progesterone powder with hormone free serum as standard matrix. Optimization and validation of the assay were carried out. The results obtained provide a low cost, simple, sensitive, specific and accurate RIA system of progesterone based on magnetizable solid phase separation. This may be extremely helpful in diagnosis and proper management of ovulation during childbearing years

  13. Development Of Solid Phase Radioimmunoassay Using Antibody Coupled Cellulose Particles For Measurement Of Prolactin In Human Serum

    International Nuclear Information System (INIS)

    Abdel-Ghany, I.Y.

    2013-01-01

    The objective of the present study was to prepare solid phase radioimmunoassay (RIA) reagents. Development as well as optimization and validation of RIA system using solid phase cellulose particles for the measurement of prolactin (PRL) in human serum were described. The production of polyclonal antibodies was carried out by immunizing three Balb/C mice intraperitoneal through primary injection and two booster doses. The activation of cellulose particles using 1,1-carbonyl diimidazole (CDI) and coupling of these solid phase particles with IgG fraction of mouse anti-PRL were carried out. Preparation of 125 I-PRL tracer was prepared using lactoperoxidase method then purified by gel filtration using sephadex G-100. The PRL standards were prepared using a highly purified PRL antigen with assay buffer as standard matrix. Optimization and validation of the assay were carried out. The results obtained provide a low cost, simple, sensitive, specific and accurate RIA system of prolactin based on solid phase separation. These cellulose particles retain their characteristics during storage for 6 months at 4 degree C. In conclusion, this assay could be used as a useful diagnostic tool for pituitary dysfunctions and possible reproductive disability

  14. General approach to standardization of the solid-phase radioimmunoassay for quantitation of class-specific antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Zollinger, W D; Boslego, J W [Walter Reed Army Inst. of Research, Washington, DC (USA)

    1981-10-30

    The feasibility of using an anti-human immunoglobulin/human immunoglobulin/(/sup 125/I)anti-human immunoglobulin 'sandwich' in a solid-phase radioimmunoassay to produce a standard curve which could be used to quantitate antigen-specific antibody of a particular immunoglobulin class was investigated. The amount of secondary antibody (SAb) bound was determined as a function of whether the primary antibody (PAb) was bound to its specific solid-phase antigen or by a solid-phase anti-human immunoglobulin. No significant difference between the two values was observed. Quantitation of anti-tetanus toxoid antibody by this method was in a good agreement with quantitative precipitin tests. Comparison of SAb binding as a function of the way the PAb is bound was extended to class-specific PAb by use of murine monoclonal antibodies to meningococcal antigens. In most cases somewhat greater binding of SAb occurred when PAb was bound to antigen, but in several cases where low avidity antibody and/or poor quality antigens were used, greater SAb binding occurred when PAb was bound by anti-mouse immunoglobulin. The results indicate that this approach may be useful as a general method for standardizing the SPRIA and other solid-phase immunoassays such as the ELISA to measure class-specific antibody.

  15. 3H and 125I radioimmunoassays of haloperidol compared with fluoroimmunoassay involving antibody coupled to magnetizable solid phase

    International Nuclear Information System (INIS)

    Rowell, F.J.; Hui, S.M.; Kamel, S.R.

    1981-01-01

    Radioimmunoassays for haloperidol are described, involving use of tritium-or 125 I-labeled drug or tritium-labeled spiroperidol, and a rabbit antiserum to a drug/bovine serum albumin conjugate. The 125 I-labeled drug was prepared by the Chloramine T iodination technique. A fluoroimmunoassay for haloperidol is also described in which the antiserum is coupled to magnetizable solid-phase medium, and fluorescein-labeled haloperidol is used. The assays have acceptable accuracy, precision, and reproducibility, and are specific for haloperidol and similar butyrophenones, with no significant interference from known metabolites and other drugs. Only the radioimmunoassays have sufficient sensitivity to cover the whole range of haloperidol concentrations in serum. The fluoroimmunoassay can be used to monitor high concentrations of haloperidol in 150 μL samples or the complete concentration range of 1-mL serum samples that are extracted and concentrated before assay

  16. 3H and 125I radioimmunoassays of haloperidol compared with fluoroimmunoassay involving antibody coupled to magnetizable solid phase

    International Nuclear Information System (INIS)

    Rowell, F.J.; Hui, S.M.; Kamel, S.R.

    1981-01-01

    Radioimmunoassays for haloperidol are described, involving use of tritium- or 125I-labeled drug or tritium-labeled spiroperidol, and a rabbit antiserum to a drug/bovine serum albumin conjugate. The 125I-labeled drug was prepared by the Chloramine T iodination technique. A fluoroimmunoassay for haloperidol is also described in which the antiserum is coupled to magnetizable solid-phase medium, and fluorescein-labeled haloperidol is used. The assays have acceptable accuracy, precision, and reproducibility, and are specific for haloperidol and similar butyrophenones, with no significant interference from known metabolites and other drugs. Only the radioimmunoassays have sufficient sensitivity to cover the whole range of haloperidol concentrations in serum. The fluoroimmunoassay can be used to monitor high concentrations of haloperidol in 150-microL samples or the complete concentration range of 1-mL serum samples that are extracted and concentrated before assay

  17. Solid-phase radioimmunoassay for Epstein-Barr virus-associated membrane antigen prepared from B95-8 cell culture supernatants

    International Nuclear Information System (INIS)

    Doelken, G.; Klein, G.

    1977-01-01

    Epstein-Barr virus (EBV)-associated membrane antigen (MA) was concentrated from B95-8 cell culture media by precipitation with polyethylene glycol followed by chromatography on Bio-Gel A-50m. In a RAJI cell-binding assay, MA-positive material could only be found in the void volume of the column. After ultracentrifugation all antigenic activity appeared in the pellet, which suggested that MA was present in aggregates, presumably fragments of cellular membranes and/or virus envelopes. The MA-containing preparation was photopolymerized in polyacrylamide gel. The homogenized gel was used in a solid-phase radioimmunoassay with 125 I-labeled IgG from an anti-MA positive reference serum and an anti-MA negative control serum. The specificity of the reaction was confirmed in blocking tests with anti-EBV positive and negative sera. A good correlation was found between the results obtained in the radioimmunoassay and the results obtained in direct immunofluorescence tests for the detection of MA. The existence of at least two subspecificities of the MA complex could be confirmed by this radioimmunoassay

  18. Solid Phase Radioimmunoassay for Measuring Serum Triiodothyronine and Thyroxine using Different Preparations of Their Labeled Hormones

    International Nuclear Information System (INIS)

    El Kolaly, M.T; Mehany, N.L; Ayyoub, S.M.; Hassan, S.E.M.

    2005-01-01

    The goal of the present work was oriented to prepare stable polystyrene coated tubes for direct radioimmunoassay (RIA) of triiodothyronine (T 3 ) and thyroxine (T 4 ) in human serum or plasma. Coating process was performed using sheep polyclonal antisera specific for each of T 3 and T 4 . The stability study showed that these tubes could be stored for up to one year at 4 degree without any appreciable reduction in their binding. The preparations of 25 I-T 3 and 125 I-T 4 were carried out by two different methods [chloramine-T(Ch-T) and iodogen] . It was found that Ch-T method gave approximately the same results as iodogen method. Twenty five samples of different thyroid status were assayed for T 3 and T 4 using the present systems and with commerically available kits (coated tubes, DPC). The statistical analysis revealed good correlations between the results from the present systems using T 3 and T 4 tracers prepared by Ch-T and iodogen methods and The DPC kits. This may be extremely helpful in diagnosis and proper management of thyroid dysfunctions

  19. Development of a solid-phase radioimmunoassay for antibody to antigens of Babesia bovis infected bovine erythrocytes

    Energy Technology Data Exchange (ETDEWEB)

    Kahl, L.P.; Anders, R.F.; Mitchell, G.F. (Walter and Eliza Hall Inst. of Medical Research, Parkville (Australia)); Callow, L.L.; Rodwell, B.J. (Animal Research Inst. Wacol (Australia). Tick Fever Research Centre)

    1982-06-01

    A quantitative solid-phase radioimmunoassay (RIA) has been developed for the purpose of ranking sera from exposed animals according to their titre of anti-B. bovis antibody. The antigen was a sonicate of lysed infected blood cells, and antibody binding was detected with /sup 125/I-labelled anti-bovine IgG. The assay was tested using sera from experimentally infected splenectomized and intact cattle and from animals resident in an endemic area. A high specificity for B. bovis was demonstrated. There was good agreement in identifying exposed cattle when the test was compared with an indirect fluorescent antibody (IFA) test although no correlation was seen between titres obtained in the two tests. Analysis of the effects of challenge infection with B. bovis on IFA and RIA titres in previously exposed animals illustrated that the RIA was a more sensitive test for detecting changes in antibody titre.

  20. Rapid solid-phase radioimmunoassay for detection of equine infectious anemia viral antigen and antibodies: parameters involved in standardization

    International Nuclear Information System (INIS)

    Horenstein, A.L.; Feinstein, R.E.

    1985-01-01

    Solid-phase radioimmunoassays (SPRIA) are described for the detection of equine infectious anemia (EIA) viral antigen and antibodies. Protein-antigen P29 currently used in the agar-gel immunodiffusion (AGID) test was used as antigen in the SPRIA. The specificity of the reaction was assessed by inhibition with the antigen. The reaction of immune serum against EIA-virus antigen adsorbed to the wells, was completely inhibited by the antigen in solution. This property was applied in an indirect competitive SPRIA for the detection of viral protein P29. The detection threshold of the SPRIA for EIA virus protein was about 5 ng and about 1 ng of antibody can be detected. The assay is rapid, specific and sensitive and allows the testing of multiple serum samples with the advantage of employing a single secondary labelled antibody. (orig.)

  1. Detection and purification of rat and goat immunoglobulin G antibodies using protein G-based solid phase radioimmunoassays

    International Nuclear Information System (INIS)

    Nilson, B.; Aakerstroem, B.; Bjoerck, L.

    1986-01-01

    Using the newly described streptococcal surface protein, protein G, which has powerful immunoglobulin G binding properties, solid-phase radioimmunoassays were developed for the quantitation of goat and rat immunoglobulin G bound to the plastic surface of microtiter plates. The binding of goat immunoglobulin G to the surface via a specific antigen (guinea pig alpha 1 -microglobulin) permitted the determination of antigen-specific antibodies with a detection limit of 50-100 ng. Optimum assay conditions were established and the whole assay procedure could be brought to completion at room temperature in less than a working day. The value of the assays was illustrated by monitoring rat and goat immunoglobulin G antibodies during their purification from whole sera by classical chromatographic procedures. (Auth.)

  2. Routine ultramicro-measurement of human growth hormone in plasma by solid-phase radioimmunoassay and its clinical application

    International Nuclear Information System (INIS)

    Ogawa, Norio; Takahara, Jiro; Ofuji, Tadashi

    1975-01-01

    The development and application of the method for the ultramicromeasurement of human growth hormone (HGH) in plasma based on the solid-phase radioimmunoassay (RIA) by using antibody-coated disposable microtiter trays was reported. There was no statistical significance between the basal HGH level obtained from this method and that from the double-antibody RIA in normal subjects. On the other hand, the mean basal plasma HGH level after an overnight fasting in 21 hypopituitary patients was 484 pg/ml (+-282; 1 SD) by this method, and this was significantly lower (P<0.001) than 1376 pg/ml (+-498; 1 SD) by the double-antibody RIA. These data show that determination of basal plasma HGH levels by this method is of much value in the diagnosis of hypopituitarism. (JPN)

  3. Measurement of IgG antibodies to house dust mite and grass pollen by a solid-phase radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Delespesse, G; Debisschop, M J; Flament, J [Hopital Saint Pierre, Louvain (Belgium). Lab. de Recherches de la Clinique Medicale

    1979-09-01

    A solid-phase radioimmunoassay was used to measure specific IgG antibodies to either Dermatophagoides pteronyssinus (DPT) or grass pollens. Radiolabelled protein A from Staphylococcus aureus (SpA) was used to determine the IgG antibodies attached to the microtubes. The binding of IgG from either normal or allergic sera to DPT-coated tubes was antigen specific and mediated by the Fab fragment of the immunoglobulin. IgG antibodies from non-allergic serum competed with IgE antibodies to DPT. IgE antibodies did not significantly interfere with the assay. Indeed heating a reaginic serum resulted in a striking reduction of the (/sup 125/I) anti- IgE binding to allergen-coated tubes without modifying the (/sup 125/I)-SpA binding. Furthermore, filtration of a reaginic serum through Sephacryl S-200 separated a peak of IgE antibodies. The solid phase method was more sensitive than a double-antibody technique employing the same DPT extract as labelled antigen. Non-allergic subjects had less IgG antibodies to DPT or grass pollens than allergic patients. In untreated patients, there was a good correlation between levels of IgG and IgE antibodies to grass pollens but not to DPT. Patients hyposensitized to house dust mite had on the average three times more specific IgG antibodies than untreated cases. (author).

  4. Measurement of IgG antibodies to house dust mite and grass pollen by a solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Delespesse, G.; Debisschop, M.J.; Flament, J.

    1979-01-01

    A solid-phase radioimmunoassay was used to measure specific IgG antibodies to either Dermatophagoides pteronyssinus (DPT) or grass pollens. Radiolabelled protein A from Staphylococcus aureus (SpA) was used to determine the IgG antibodies attached to the microtubes. The binding of IgG from either normal or allergic sera to DPT-coated tubes was antigen specific and mediated by the Fab fragment of the immunoglobulin. IgG antibodies from non-allergic serum competed with IgE antibodies to DPT. IgE antibodies did not significantly interfere with the assay. Indeed heating a reaginic serum resulted in a striking reduction of the ( 125 I) anti- IgE binding to allergen-coated tubes without modifying the ( 125 I)-SpA binding. Furthermore, filtration of a reaginic serum through Sephacryl S-200 separated a peak of IgE antibodies. The solid phase method was more sensitive than a double-antibody technique employing the same DPT extract as labelled antigen. Non-allergic subjects had less IgG antibodies to DPT or grass pollens than allergic patients. In untreated patients, there was a good correlation between levels of IgG and IgE antibodies to grass pollens but not to DPT. Patients hyposensitized to house dust mite had on the average three times more specific IgG antibodies than untreated cases. (author)

  5. A simplified radioimmunoassay for digoxin determination using a 125-I-labelled solid-phase kit

    International Nuclear Information System (INIS)

    Doering, W.; Bluemel, E.

    1978-01-01

    Our experience with a commercially available kit (Radioimmunoassay DIGOXIN, Boehringer, Mannheim) using ( 125 J)-labelled digoxin and antibody-coated tubes is reported. This simplified method requires only two pipetting steps per sample and results can be obtained in 70 min. The intra- and interassay coefficient of variation ranged between 7% and 8%. The specific digoxin antibody antibody gave no clinical relevant cross-reactions with spironolactone or prednisone ( [de

  6. Solid-phase radioimmunoassay for the detection fo IgG antibodies to gramineae pollen (Dactylis glomerata) and to acarida (dermatophagoides Pteronyssinus)

    International Nuclear Information System (INIS)

    Guilloux, L.; Ville, G.

    1985-01-01

    A solid-phase radioimmunoassay using 125 I-protein A onto polystyrene microplates, was applied successfully for the detection of IgG antibodies to acarida and to grass pollen in allergic patients and in patients undergoing desensitization therapy [fr

  7. Frequency of hepatitis B surface antibody (anti-HBs) in various Canadian populations as measured by modified solid-phase radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Bishai, F R; MacMillan, S; Rhodes, A J [Ontario Ministry of Health, Toronto, Ont.; Dempster, G [University Hospital, Saskatoon, Sask.; Spence, L [Toronto Univ., Ontario (Canada). Dept. of Medicine; Wrobel, D M [Toronto Centre of Canadian Red Cross Blood Transfusion Service, Ont.

    1977-01-01

    A short incubation solid-phase radioimmunoassay test was developed and used for the detection of hepatitis B surface antibody (anti-HBs) in the sera collected from patients recovering from hepatitis B infection, health care personnel, staff and residents of an intstitution for the mentally retarded and in pregnant and non-pregnant women in Ontario.

  8. Frequency of hepatitis B surface antibody (anti-HBs) in various Canadian populations as measured by modified solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Bishai, F.R.; MacMillan, S.; Rhodes, A.J.; Dempster, G.; Spence, L.; Wrobel, D.M.

    1977-01-01

    A short incubation solid-phase radioimmunoassay test was developed and used for the detection of hepatitis B surface antibody (anti-HBs) in the sera collected from patients recovering from hepatitis B infection, health care personnel, staff and residents of an intstitution for the mentally retarded and in pregnant and non-pregnant women in Ontario. (author)

  9. Detection of viral antigens by solid phase radioimmunoassay on polyethylene film

    Energy Technology Data Exchange (ETDEWEB)

    Prokudina, E N; Semenova, N P; Zhdanov, V M

    1986-04-01

    Polyethylene film, without any pretreatment, may serve as a solid phase (SP) for RIA. Viral antigens (HBsAg, and influenza virus) are detected by SP-RIA on the film with a sensitivity of about 2-3 ng/ml or 40-60 pg/assay. The use of polyethylene film allows one to record RIA autographically. The use of micro amounts of reagents and specimens tested is an added advantage. No special equipment is necessary, the method is inexpensive, easy to perform and may be used for mass screening. (Auth.). 7 refs.; 4 figs.

  10. Highly sensitive solid-phase radioimmunoassay for the assay of Plasmodium falciparum antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Avraham, H.; Golenser, J.; Gazitt, Y.; Spira, D.T.; Sulitzeanu, D. (Hebrew Univ., Jerusalem (Israel). Hadassah Medical School)

    1982-08-27

    A highly sensitive radioimmunoassay for detection of P. falciparum antibodies and antigens is described. A partially purified P. falciparum antigen preparation is obtained from in vitro cultured parasites enriched after gelatin sedimentation by sonicating the infected red blood cells and precipitating the proteins with 50% saturated ammonium sulfate. The precipitate is dissolved in buffer, ultracentrifuged and used to coat wells of microtiter plates. Anti-P. falciparum antibodies are detected by incubating antiserum dilutions in the coated wells and detecting the bound IgG with radioiodinated staphylococcal protein A. P. falciparum antigens are detected by their ability to inhibit binding of antibodies to the coated wells. Sera of individuals with a history of P. falciparum infection contain antibodies detectable at a dilution of 1:75,000. P. falciparum RBC infected in vitro can be detected at levels of parasitemia of the order of 1 parasite or less per 10/sup 6/ RBC.

  11. Detection of hepatitis B surface antigen by solid phase radioimmunoassay and immunometric assay (using enhanced luminescence)

    International Nuclear Information System (INIS)

    Nicholson, S.; Efandis, T.; Gust, I.

    1991-01-01

    A study was performed to assess the sensitivity and specificity of the amerlite monoclonal immunoassay for detection of hepatitis B surface antigen (HBsAG) by comparison with the Abbott Ausria II radioimmunoassay (RI). Serial bleeds from 34 patients with acute or chronic hepatitis B were tested by both assays. The Abbott Ausria II assay detected HBsAG longer than the Amersham Amerlite assay on two occasions and earlier on one occasion. Twelve patients with low HBsAg positive results (confirmed by Ausria II) were tested by the Amerlite assay, four were repeatably positive, five repeatably negative and three gave borderline results (which on repeat testing were negative). A similar trend was seen when a panel of sera containing known concentrations of HBsAG was tested. Replicate testing of 10 specimens eight times showed very good reproducibility by the Amerlite assay. Overall, the specificity of both assays was comparable, however differences in sensitivity were observed. 3 tabs

  12. A highly sensitive solid-phase radioimmunoassay for the assay of Plasmodium falciparum antigens and antibodies

    International Nuclear Information System (INIS)

    Avraham, H.; Golenser, J.; Gazitt, Y.; Spira, D.T.; Sulitzeanu, D.

    1982-01-01

    A highly sensitive radioimmunoassay for detection of P. falciparum antibodies and antigens is described. A partially purified P. falciparum antigen preparation is obtained from in vitro cultured parasites enriched after gelatin sedimentation by sonicating the infected red blood cells and precipitating the proteins with 50% saturated ammonium sulfate. The precipitate is dissolved in buffer, ultracentrifuged and used to coat wells of microtiter plates. Anti-P. falciparum antibodies are detected by incubating antiserum dilutions in the coated wells and detecting the bound IgG with radioiodinated staphylococcal protein A. P. falciparum antigens are detected by their ability to inhibit binding of antibodies to the coated wells. Sera of individuals with a history of P. falciparum infection contain antibodies detectable at a dilution of 1:75,000. P. falciparum RBC infected in vitro can be detected at levels of parasitemia of the order of 1 parasite or less per 10 6 RBC. (Auth.)

  13. A ''reverse'' solid-phase radio-immuno-assay for IgM-antibodies to hepatitis A virus

    International Nuclear Information System (INIS)

    Meurman, O.H.; Matter, L.; Krishna, R.V.; Krech, U.H.

    1981-01-01

    A ''reverse'' solid-phase radio-immuno-assay for IgM antibodies to hepatitis A virus (HAV) was developed. Anti-human IgM immunoglobulins were bound on the wells of polyvinylchloride microtiter plates. Serum specimens were incubated in the anti-human IgM coated wells and bound IgM antibodies were then assayed for antigen specificity by subsequent incubations with HAV antigen and 125 I-labelled human anti-HAV IgG. The test showed a high sensitivity and specificity for anti-HAV IgM antibodies. No false-positive reactions were observed either in the sera from patients with hepatobiliary disorders other than HAV infection or in the sera containing both rheumatoid factor and anti-HAV IgG antibodies. In acute HAV infections specific IgM antibodies were present already in the first specimens taken within a few days after the onset of jaundice. The persistence of the IgM antibodies was from 4 to 6 months. IgM antibody titers up to 1,000,000 were observed in the acute phase of HAV infection. In routine diagnostic work the titration of the sera was not necessary, since a reliable qualitative result was obtained by testing the sera in a single dilution of 1:100. A similar ''reverse'' immuno-assay principle may be adaptable for the diagnostic determination of IgM antibodies to different viral and microbial antigens. (author)

  14. The diagnosis of malaria infection using a solid-phase radioimmunoassay for the detection of malaria antigens

    International Nuclear Information System (INIS)

    Mackey, L.; Perrin, L.; Leemans, E.; Lambert, P.H.

    1980-01-01

    A method was devised to show that malaria parasites can be detected serologically in infected blood with a high degree of sensitivity. Using a murine malaria model, parasites were demonstrated in a solid-phase radio-immunoassay which measured antibody-binding inhibition. Lysed red blood cells (r.b.c.) were incubated with labelled specific antibody and were then reacted in antigen-coated tubes. The degree of inhibition of antibody binding in the tubes correlated with the level of parasitaemia in the test blood. Using homologous antisera the test detected infection at a level of 1 parasite/million r.b.c.. The specificity of the method was shown by comparison of antibody-binding inhibition in normal and infected r.b.c. and in r.b.c. from non-infected mice with induced reticulocytosis. The sensitivity was shown in vitro in tests of serially diluted blood of high parasitaemia and in vivo for the detection of early infection. The presence of antibody in the test blood did not significantly affect the sensitivity of parasite detection. (author)

  15. Solid phase radioimmunoassay for quantitation of IgM rheumatoid factor (RF). Comparison with agglutination techniques and radioimmunoprecipitation polyethylene glycol assay (RIPEGA)

    Energy Technology Data Exchange (ETDEWEB)

    Herrmann, D.; Jaeger, L.; Hein, G.; Henzgen, M.; Fiebig, H.; Schlenvoigt, G.; Vogelsang, H. (Friedrich-Schiller-Universitaet, Jena (German Democratic Republic). Bereich Medizin; Karl-Marx-Universitaet, Leipzig (German Democratic Republic). Sektion Biowissenschaften)

    1985-01-01

    A solid-phase radioimmunoassay capable of detecting nanogram quantities of human IgM rheumatoid factor using a monoclonal anti-..mu..-chain antibody is described. Human IgG did not interfere with the detection of IgM RF by this method. The small nonspecific binding of nonRF IgM to the human IgG coated tubes utilized in the assay must be corrected for by assaying samples in parallel bovine serum albumin coated control tubes only in cases of deviation of IgM from normal range. 69 coded and randomly arranged sera from patients with rheumatoid arthritis (RA), nonrheumatic joint diseases and healthy adult control subjects were investigated by this method, agglutination techniques as well as RIPEGA. A good correlation between solid-phase radioimmunoassay and agglutination techniques was found. Patients with seropositive RA had significantly higher concentrations of IgM RF than seronegative RA patients or control subjects.

  16. Use of a solid-phase radioimmunoassay and formalin-fixed whole bacterial antigen in the detection of antigen-specific immunoglobulin in prostatic fluid.

    OpenAIRE

    Shortliffe, L M; Wehner, N; Stamey, T A

    1981-01-01

    The prostatic fluid of two patients with Escherichia coli bacterial prostatitis was analyzed for evidence of a local immune response to bacterial infection. A solid-phase radioimmunoassay was modified to measure the immunoglobulin (Ig)A and IgG antigen-specific antibody responses to infecting bacteria in serum and prostatic fluid from patient. Formalin-fixed whole E. coli were used as antigen. In one patient with acute E. coli prostatic infection, measurements of antigen-specific antibody con...

  17. Anti-double strand (ds) DNA antibody formation by NZB/W (F1) spleen cells in a microculture system detected by solid phase radioimmunoassay.

    Science.gov (United States)

    Okudaira, H; Terada, E; Ogita, T; Aotsuka, S; Yokohari, R

    1981-01-01

    A solid-phase radioimmunoassay method was devised to detect mouse anti-double strand (ds) DNA antibody. This method could easily detect the anti-dsDNA antibody in 1 : 10,000 dilutions (1 unit) of pooled 9-10-month-old female NZB/W F1 sera. The sensitivity was about 10(3)- and 10(2)-fold higher than that of the modified Farr method and of the double antibody technique respectively. NZB/W mice developed high titer anti-dsDNA antibody as they grew older. Spleen cells brought to a microculture system using flat-bottomed polystyrene plates produced anti-dsDNA antibody clearly detectable by solid-phase radioimmunoassay. Anti-dsDNA antibody produced in vitro (y units) was in close correlation with the anti-dsDNA antibody titer of the spleen donor (x units) (y = 4.8 X 10(-2) x -65, gamma = 0.94, P less than 0.001). A combination of the microculture system and solid-phase radioimmunoassay was recommended for the characterization of anti-dsDNA antibody-forming cells.

  18. Anti-double strand (ds) DNA antibody formation by NZB/W (F1) spleen cells in a microculture system detected by solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Okudaira, H.; Terada, E.; Ogita, T.; Aotsuka, S.; Yokohari, R.

    1981-01-01

    A solid-phase radioimmunoassay method was devised to detect mouse anti-double strand (ds) DNA antibody. This method could easily detect the anti-ds DNA antibody in 1 : 10,000 dilutions (1 unit) of pooled 9-10 month-old female NZB/W F1 sera. The sensitivity was about 10 3 and 10 2 -fold higher than that of the modified Farr method and of the double antibody technique respectively. NZB/W mice developed high titer anti-dsDNA antibody as they grew older. Spleen cells brought to a microculture system using flat-bottomed polystyrene plates produced anti-dsDNA antibody clearly detectable by solid-phase radioimmunoassay. Anti-dsDNA antibody produced in vitro (y units) was in close correlation with the anti-dsDNA antibody titer of the spleen donor (x units) (y = 4.8 X 10 -2 x-65, γ = 0.94, P < 0.001). A combination of the microculture system and solid-phase radioimmunoassay was recommended for the characterization of anti-dsDNA antibody-forming cells. (Auth.)

  19. Evaluation of two reverse passive haemagglutination techniques and a solid-phase radioimmunoassay for detection of hepatitis B surface antigen

    Energy Technology Data Exchange (ETDEWEB)

    Zhuang, H [Beijing Medical College (China); Coulepis, A G; Gust, I D [Fairfield Hospital for Communicable Diseases, Melbourne (Australia)

    1972-08-01

    The sensitivity and specificity of two commercially available reverse passive haemagglutination tests (Hepatest and Raphadex B) for the detection of hepatitis B surface antigen, were compared with the most widely used radioimmunoassay (Ausria II-125). A selected group of 282 sera were tested: these included the Australian hepatitis B reference panel, and a batch of 257 sera collected from patients with acute hepatitis B, chronic carriers of hepatitis B surface antigen and two populations in which hepatitis B virus infection is known to be endemic. The two reverse passive haemagglutination techniques were of comparable sensitivity but slightly less sensitive than radioimmunoassay. While radioimmunoassay still remains the test of choice for blood transfusion services, the reverse passive haemagglutination techniques are of great value for smaller laboratories and for field studies because of their longer shelf life, the absence of radioactive reagents and the lack of need to acquire a gammacounter.

  20. Observation on the stability of the solid phase microparticles separating technique in T3, T4 radioimmunoassay

    International Nuclear Information System (INIS)

    Chen Guangliang; Chen Xunmin

    1995-01-01

    The solid phase T 3 ,T 4 RIA is adopted at various laboratories. The data analysis from the effective dose and quality control of samples indicates that the separation technique is of good effect and high stability. It is an effective separation technique for the quality control in RIA

  1. Establishment of an indirect solid phase radioimmunoassay for the detection of HSV-type I-specific antibodies in human serum

    International Nuclear Information System (INIS)

    Buchow, H.

    1982-01-01

    An indirect solid phase radioimmunoassay (IFRIA) was developed for the detection in human serum of antibodies against Herpes simplex virus (HSV) type I. The IFRIA was carried out according to the 'sandwich' principle. In comparison to other serological routine methods, especially the complement binding reaction (CBR) commonly used for HSV diagnostic, the IFRIA excelled by being a test which is quick to carry out and by lacking the subjectivity by the researcher in the evaluation of the test results, as well as by the use of patients serum which had not been previously treated. Comparative studies between IFRIA and CBR resulted in no agreement between the respectively attained maximum titer. As a reason for this the different qualities of the antibodies which can be determined by each test were discussed. For the addition of this test to the routine diagnostic further studies in the preservation of the specificity of the antigen in the case of longer storage are requisite. (orig.) [de

  2. A solid-phase radioimmunoassay for measurement of circulating antibody titres to wheat gliadin and its subfractions in patients with adult coeliac disease

    International Nuclear Information System (INIS)

    Ciclitira, P.J.; Ellis, H.J.; Evans, D.J.

    1983-01-01

    A solid-phase radioimmunoassay for the measurement of circulating antibody titres to wheat gliadin is described. Using this assay, the authors have measured antibody titres to unfractionated gliadin in normal healthy controls, in coeliac patients on a gluten-free or a normal diet, and in patients with ulcerative colitis and Crohn's disease. High titres of antibodies to unfractionated gliadin were observed only in the patients with untreated coeliac disease. Antibody titres to α, #betta#, #betta# and #betta# gliadin subfractions were measured in patients with untreated coeliac disease and compared with titres in normal controls. Patients with untreated coeliac disease had higher antibody titres to the gliadin subfractions. No specific pattern of circulating antibody titres to gliadin subfractions was observed in the untreated coeliac patients which would provide a diagnostic profile. These results suggest shared antigenicity between the gliadin subfractions. (Auth.)

  3. Solid-phase radioimmunoassay for measurement of circulating antibody titres to wheat gliadin and its subfractions in patients with adult coeliac disease

    Energy Technology Data Exchange (ETDEWEB)

    Ciclitira, P.J.; Ellis, H.J. (Guy' s Hospital, London (UK)); Evans, D.J. (Hammersmith Hospital, London (UK))

    1983-08-26

    A solid-phase radioimmunoassay for the measurement of circulating antibody titres to wheat gliadin is described. Using this assay, the authors have measured antibody titres to unfractionated gliadin in normal healthy controls, in coeliac patients on a gluten-free or a normal diet, and in patients with ulcerative colitis and Crohn's disease. High titres of antibodies to unfractionated gliadin were observed only in the patients with untreated coeliac disease. Antibody titres to ..cap alpha.., ..beta.., ..gamma.. and ..omega.. gliadin subfractions were measured in patients with untreated coeliac disease and compared with titres in normal controls. Patients with untreated coeliac disease had higher antibody titres to the gliadin subfractions. No specific pattern of circulating antibody titres to gliadin subfractions was observed in the untreated coeliac patients which would provide a diagnostic profile. These results suggest shared antigenicity between the gliadin subfractions.

  4. Use of a solid-phase 3H-radioimmunoassay for the measurement of immunoglobulin produced in short-term cultures of antibody-secreting cells

    International Nuclear Information System (INIS)

    Mongini, P.K.A.; Heber-Katz, E.

    1982-01-01

    A solid-phase radioimmunoassay (RIA) for assaying immunoglobulin produced from antibody-secreting myeloma, hybridoma and immune spleen cells is described. Specific antibody is detected by culturing antibody-producing cells on antigen-coated flexible polyvinylchloride microtiter wells, washing away the cells, and measuring the bound specific antibody with tritiated affinity-purified anti-isotype reagents. Antibody produced from 10 3 myeloma cells can be detected with as little as 4 h of incubation. With 24-48 h of incubation, antibody from as few as approximately 3-15 myeloma, hybridoma or immune spleen plaque-forming cells (PFC) can be detected. This culture-well RIA has certain distinct advantages over the hemolytic PFC assay and RIA assays in which antibody in culture supernatants is measured. (Auth.)

  5. Type-specific IgG and IgA antibodies in old lymphogranuloma venerum determined by solid-phase radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Meurman, O.; Terho, P.; Sonck, C.E.

    1981-01-01

    A solid-phase radioimmunoassay (RIA) using egg-grown purified Chlamydia trachomatis lymphogranuloma venereum (LGV) serotypes L1, L2, and L3 as antigen was used to measure type-specific IgG and IgA antibodies in sera of 36 patients who had contracted LGV infection about 40 years ago. The RIA test gave compatible results with the standard microimmunofluorescence test, and by RIA it was possible to identify the infecting serotype in 30 out of 36 patients studied. In 28 cases this was L2 and in two cases L1. Each patient had IgG antibodies and most of them (80%) IgA antibodies to at least one of the LGV serotypes. The antibody titers were still high 40 years after the acute infection, being higher than in male patients with a recent chlamydial urethritis. Highest antibody titers were detected in LGV patients who had a severe disease with intestinal involvement.

  6. Type-specific IgG and IgA antibodies in old lymphogranuloma venerum determined by solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Meurman, O.; Terho, P.; Sonck, C.E.

    1981-01-01

    A solid-phase radioimmunoassay (RIA) using egg-grown purified Chlamydia trachomatis lymphogranuloma venereum (LGV) serotypes L1, L2, and L3 as antigen was used to measure type-specific IgG and IgA antibodies in sera of 36 patients who had contracted LGV infection about 40 years ago. The RIA test gave compatible results with the standard microimmunofluorescence test, and by RIA it was possible to identify the infecting serotype in 30 out of 36 patients studied. In 28 cases this was L2 and in two cases L1. Each patient had IgG antibodies and most of them (80%) IgA antibodies to at least one of the LGV serotypes. The antibody titers were still high 40 years after the acute infection, being higher than in male patients with a recent chlamydial urethritis. Highest antibody titers were detected in LGV patients who had a severe disease with intestinal involvement. (orig.)

  7. The effect of high antigen density on solid-phase radioimmunoassays for antibody regardless of immunoglobulin class

    International Nuclear Information System (INIS)

    Rubin, R.L.; Hardtke, M.A.; Carr, R.I.

    1980-01-01

    Human sera containing antibody to casein or to bovine serum albumin were used to assess the validity and utility of a solid-phase assay for quantitating antibody activity. Rabbit anti-human immunoglobulin radiolabeled with 125 I and capable of reacting with all human immunoglobulin classes was used to detect antibody bound to antigen immobilized to polystyrene tubes by a new covalent technique. This method results in very high antigen concentrations in highly stable association with polystyrene tubes. Kinetic and absorption studies demonstrated that low avidity antibodies are better detected when antigen is immobilized by the covalent method than when passively adsorbed. Conditions are described for minimizing artifactual interactions and for obtaining results similar to those obtained with conventional, liquid-phase assays. Failure to reach equilibrium in solid-phase assays and other problems are proposed to explain, in part, the inability to obtain a better correlation between solid- and liquid-phase immunoassays. (Auth.)

  8. Serological analysis of human IgG and IgE anti-insulin antibodies by solid-phase radioimmunoassays

    International Nuclear Information System (INIS)

    Hamilton, R.G.; Rendell, M.; Adkinson, N.F. Jr.

    1980-01-01

    A single solid-phase assay system which is useful for quantitative measurement of both IgG and IgE anti-insulin antibodies in human serum has been developed. Insulin-specific immunoglobulins are absorbed from human serum by excess quantities of insulin-agarose. After washes to remove unbound immunoglobulins, radioiodinated Staph A or rabbit anti-human IgE is added to detect bound IgG or IgE anbitodies, respectively

  9. Rapid washing of filter paper discs in a solid-phase radioimmunoassay with a constant flow washing device

    International Nuclear Information System (INIS)

    Kemeny, D.M.; West, F.B.

    1982-01-01

    A machine has been developed for the rapid washing of the cellulose filter paper discs that are used in a number of radioimmunoassays. The machine is simple in design, easy to use, and is capable of washing 96 filter paper discs simultaneously. The efficiency of the machine is demonstrated by a RAST assay for measuring IgE antibodies to the venom. Time taken to wash the discs was reduced 3-fold without loss of sensitivity or reproducibility. (Auth.)

  10. Evaluation of the double antibody - solid phase radioimmunoassay technique in plasma LH and FSH and urinary LH measurements

    International Nuclear Information System (INIS)

    Karonen, S.-L.; Laehteenmaeki, P.; Hohenthal, U.; Adlercreutz, H.

    1978-01-01

    Double antibody phase (DASP) radioimmunoassay methods for plasma LH and FSH and urinary LH were developed and carefully evaluated as to their reliability and practicability. The peptide hormones were iodinated enzymatically with immobilized lactoperoxidase which resulted in pure and stable products of unchanged immunoreactivity. The sensitivities of these assay methods are 0.02, 0.17 and 0.20 mlU/tube for plasma LH (MRC 68/40) and FSH (MRC 68/39) and urinary LH (IRP-HMG, urinary), respectively. Interassay coefficients of variation obtained over a 6-18 month period were 14.2, 14.7 and 12.8%, respectively. The latter values for plasma LH and FSH assays were obtained from one level pool samples, and the value for urinary LH is the mean of those obtained from two pools of different levels. Plasma reference values for LH and FSH obtained using these methods are about 1.8-2.9 times higher than those cited for other types of radioimmunoassay. However, the values obtained for LH in urine are similar to those reported in the literature. It is suggested that the DASP technique is less influenced by interference from plasma proteins and because of this gives plasma values closer to the true ones. It is concluded that the methods are well suited for use as routine clinical assays in laboratories with a high work load. (Auth.)

  11. Prebeta-migrating high density lipoprotein: quantitation in normal and hyperlipidemic plasma by solid phase radioimmunoassay following electrophoretic transfer

    International Nuclear Information System (INIS)

    Ishida, B.Y.; Frolich, J.; Fielding, C.J.

    1987-01-01

    A quantitative solid phase immunoassay has been developed for the determination of the mass of electrophoretically separated prebeta apolipoprotein A-I (apoA-I) in human plasma. Conditions have been identified for the quantitative transfer and immunoblotting of the apolipoprotein in the absence of organic solvents or detergents. In normolipidemic plasma, the prebeta-migrating fraction of apoA-I represented 4.2 +/- 1.8% of total apoA-I (61 +/- 26 micrograms of apoA-I per ml of plasma). Significantly higher levels were found in hypercholesterolemia of genetic origin, in primary and secondary hypertriglyceridemia, and in congenital lecithin:cholesterol acyltransferase deficiency. In all cases prebeta-migrating apoA-I consisted in large part of low molecular weight lipoprotein species, compared to the size of the major, alpha-migrating apoA-I fraction

  12. Double-antibody solid-phase radioimmunoassay: a simplified phase-separation procedure applied to various ligands

    International Nuclear Information System (INIS)

    Tevaarwerk, G.J.M.; Boyle, D.A.; Hurst, C.J.; Anguish, I.; Uksik, P.

    1980-01-01

    The purpose was to develop a simplified and reliable method of separating free from antibody-bound ligand using a precipitating antibody linked to a cellulose derivative. Dose-response curves and control sera were set up in parallel for various pituitary and placental polypeptides, steroid hormones, insulin, glucagon, triiodothyronine, thyroxine, angiotensin I, calcitonin, gastrin, cyclic AMP, and digoxin. After first-antibody reactions had reached equilibrium, free and bound ligand were separated using a double-antibody solid-phase system in parallel with conventional methods, including dextran-coated charcoal, double-antibody precipitation, single-antibody solid phase, organic solvents, salt precipitation, and anion-exchange resins. The effect of variations in temperature, incubation time, protein content, pH, and amount of separating material added were studied. The results showed that separation was complete within 1 hr for small ligand molecules and within 2 hr for larger ones. Dose-response curves and control-sera results closely paralleled those obtained with conventional methods. The method was not affected by moderate variations in incubation variables. Nonspecific binding was less than 3% in all assays, while intra-assay and interassay coefficients of variation were similar to those obtained with conventional phase-separation methods. It is concluded that the method is a simple and rapid alternative phase-separation system. It has the advantage of being free from common nonspecific intersample variations, and can be applied to any assay system based on rabbit or guinea pig antibodies without preliminay time- or reagent-consuming titration or adjustments to establish optimum phase-separating conditions

  13. A solid-phase radioimmunoassay for IgG gliadin antibodies using 125I-labelled staphylococcal protein A

    International Nuclear Information System (INIS)

    Troncone, R.; Pignata, C.; Farris, E.; Ciccimarra, F.

    1983-01-01

    A sensitive radioimmunoassay for IgG gliadin antibodies is described. Serum specimens were added to wells of plastic microtitre plates coated with gliadin. After removal of the unbound material, gliadin antibodies were detected by adding 125 I-labelled staphylococcal protein A ( 125 I-SpA). Serum specimens from coeliac patients on a normal diet or on a gluten-free diet were tested, as well as sera from an age-matched control group. Measurements to obtain precise quantitative values were made with gliadin antibody-rich serum as reference standard. High titres of gliadin antibodies were found in 18 out of 19 coeliac patients on a normal diet (95%); in patients on a strict gluten-free diet serum values did not exceed 2 S.D. of the control mean. Due to the high sensitivity of the method a low but detectable amount of gliadin antibody was present in the sera of all controls. (Auth.)

  14. Solid-phase radioimmunoassay for IgG gliadin antibodies using /sup 125/I-labelled staphylococcal protein A

    Energy Technology Data Exchange (ETDEWEB)

    Troncone, R.; Pignata, C.; Farris, E.; Ciccimarra, F. (Naples Univ. (Italy). II Facolta di Medicina)

    1983-10-14

    A sensitive radioimmunoassay for IgG gliadin antibodies is described. Serum specimens were added to wells of plastic microtitre plates coated with gliadin. After removal of the unbound material, gliadin antibodies were detected by adding /sup 125/I-labelled staphylococcal protein A (/sup 125/I-SpA). Serum specimens from coeliac patients on a normal diet or on a gluten-free diet were tested, as well as sera from an age-matched control group. Measurements to obtain precise quantitative values were made with gliadin antibody-rich serum as reference standard. High titres of gliadin antibodies were found in 18 out of 19 coeliac patients on a normal diet (95%); in patients on a strict gluten-free diet serum values did not exceed 2 S.D. of the control mean. Due to the high sensitivity of the method a low but detectable amount of gliadin antibody was present in the sera of all controls.

  15. Solid-phase enzyme immunoassay or radioimmunoassay for the detection of immune complexes based on their recognition by conglutinin: conglutinin-binding test

    International Nuclear Information System (INIS)

    Casali, P.; Bossus, A.; Carpentier, N.A.; Lambert, P.H.

    1977-01-01

    Bovine conglutinin was used in a solid-phase assay for the detection of immune complexes. In a first step, the tested serum sample was incubated in polypropylene tubes coated with conglutinin to allow C3-coated immune complexes to bind to solid-phase conglutinin. In a second step, the conglutinin-bound complexes were detected using an enzyme-conjugated or radiolabelled anti-immunoglobulin antibody. The conglutinin-binding (KgB) test did not suffer from the interference of DNA, heparin or endotoxins. Its limit of sensitivity for aggregated IgG was 3 μg/ml undiluted human serum. Immune complexes prepared in vitro using tetanus toxoid, or DNA, and corresponding antibodies in human sera could be detected at various antigen/antibody ratios and at antibody concentrations lower than 8 μg/ml. The KgB test allowed for the detection of immune complexes in sera from patients with systemic lupus erythematosus, rheumatoid arthritis, idiopathic vasculitis, leprosy and leukemia. These sera were also tested using the 125 I-labelled Clq-binding activity (BA) test and the KgB test simultaneously, and a significant rank order correlation was observed. In patients with leukemia, a significant correlation was observed using three tests, KgB, 125 I-labelled Clq BA and Raji-cell radioimmunoassay (RIA). Therefore, the KgB test appears as a simple and reproducible method, utilizing a very stable reagent, with a sensitivity and specificity comparable to the other tests studied and allowing for clinical application. (author)

  16. Free thyroxine by solid phase radioimmunoassay: improvement in the laboratory diagnosis of thyroid status in severely ill patients

    Energy Technology Data Exchange (ETDEWEB)

    Bayer, M.F.; McDougall, I.R. (Stanford Univ., CA (USA). School of Medicine)

    1982-02-05

    During severe systemic illness total thyroid hormone levels are often low, and measurement of total hormones often does not differentiate between euthyroid and hypothyroid patients. Therefore serum free thyroxine levels were tested by radioimmunoassay (antibody-coated tubes, Clinical Assays) as an alternative diagnostic test in three groups of severely ill patients with subnormal triiodothyronine. Free thyroxine estimates agreed with the clinical impression and TSH in 91% of cases in group 1 (47 patients with no history or clinical evidence of thyroid disorder), in 96% of cases in group 2 (24 euthyroid patients with a history of thyroid disease, including some on thyroid replacement) and 90% of cases in group 3 (10 hypothyroid patients). By contrast, the free thyroxine index did so in only 53% (group 1), 46% (group 2) or 100% (group 3). Sequential studies showed little change in free thyroxine and TSH levels in euthyroid patients during illness and recovery, and a good negative correlation between free thyroxine and TSH in hypothyroid patients. Free thyroxine measurements (and TSH) discriminate between euthyroid and hypothyroid sick patients better than other thyroid function tests including the free thyroxine index, and can be employed routinely: a distinct advantage over free thyroxine measured by equilibrium dialysis.

  17. Chlamydial serum IgG, IgA and local IgA antibodies in patients with genital-tract infections measured by solid-phase radioimmunoassay

    International Nuclear Information System (INIS)

    Terho, P.; Meurman, O.

    1981-01-01

    A solid-phase radioimmunoassay (RIA) for IgG and IgA class antibodies to Chlamydia trachomatis was developed with C. trachomatis serotype L2 as antigen. The assay was sensitive, reproducible and correlated well with an immunofluorescence test (r = 0.85). Serum IgG antibodies were detected in 79% of Chlamydia isolation-positive versus 43% of isolation-negative male patients with urethritis and serum IgA antibodies in 53% and 21%, respectively. Urethral IgA antibodies, measured from specimens taken for chlamydial isolation, could be detected in 94% and 38%, respectively. From 737 male urethral and 909 female cervical secretions screened for the presence of IgA antibodies, about half were isolation and IgA negative. Only 4% (6/151) of male and 5.4% (2/37) of female isolation-positive specimens were IgA negative. The determination of local IgA antibodies may be used as a screening test in chlamydial genital infections. (author)

  18. Determination of parathion in biological fluids by means of direct Solid Phase Microextraction.

    OpenAIRE

    Gallardo, Eugenia; Barroso, Mário; Margalho, C.; Cruz, Angelines; Vieira, Duarte Nuno; López-Rivadulla, Manuel

    2010-01-01

    A new and simple procedure for the determination of parathion in human whole blood and urine using direct immersion (DI) solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. This technique was developed using only 100 ìL of sample, and ethion was used as internal standard (IS). A 65-ìm Carbowax/divinylbenzene (CW/DVB) SPME fibre was selected for sampling, and the main parameters affecting the SPME process such as extraction ...

  19. Direct solid-phase microextraction combined with gas and liquid chromatography for the determination of lidocaine in human urine

    NARCIS (Netherlands)

    Koster, E.H M; Hofman, N.S K; de Jong, G.J.

    Solid-phase microextraction (SPME) has been combined with gas chromatography (GC) and liquid chromatography (LC) for the determination of lidocaine in human urine. A polydimethylsiloxane (PDMS) coated fibre was directly immersed into buffered urine. Extraction conditions such as time, pH, ionic

  20. Determination of parathion in biological fluids by means of direct solid-phase microextraction.

    Science.gov (United States)

    Gallardo, E; Barroso, M; Margalho, C; Cruz, A; Vieira, D N; López-Rivadulla, M

    2006-11-01

    A new and simple procedure for the determination of parathion in human whole blood and urine using direct immersion (DI) solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS) is presented. This technique was developed using only 100 microL of sample, and ethion was used as internal standard (IS). A 65-microm Carbowax/divinylbenzene (CW/DVB) SPME fibre was selected for sampling, and the main parameters affecting the SPME process such as extraction temperature, adsorption and desorption time, salt addition, agitation and pH effect were optimized to enhance the sensitivity of the method. This optimization was also performed to allow the qualitative determination of parathion's main metabolite, paraoxon, in blood. The limits of detection and quantitation for parathion were 3 and 10 ng/mL for urine and 25 and 50 ng/mL for blood, respectively. For paraoxon, the limit of detection was 50 ng/mL in blood. The method showed linearity between the LOQ and 50 microg/mL for both matrices, with correlation coefficients ranging from 0.9954 to 0.9999. Precision and accuracy were in conformity with the criteria normally accepted in bioanalytical method validation. The mean absolute recoveries were 35.1% for urine and 6.7% for blood. Other parameters such as dilution of sample and stability were also validated. Its simplicity and the fact that only 100 microL of sample is required to accomplish the analysis make this method useful in forensic toxicology laboratories to determine this compound in intoxications, and it can be considered an alternative to other methods normally used for the determination of this compound in biological media.

  1. Fabrication of a Schottky junction diode with direct growth graphene on silicon by a solid phase reaction

    International Nuclear Information System (INIS)

    Kalita, Golap; Hirano, Ryo; Ayhan, Muhammed E; Tanemura, Masaki

    2013-01-01

    We demonstrate fabrication of a Schottky junction diode with direct growth graphene on n-Si by the solid phase reaction approach. Metal-assisted crystallization of a-C thin film was performed to synthesize transfer-free graphene directly on a SiO 2 patterned n-Si substrate. Graphene formation at the substrate and catalyst layer interface is achieved in presence of a Co catalytic and CoO carbon diffusion barrier layer. The as-synthesized material shows a linear current–voltage characteristic confirming the metallic behaviour of the graphene structure. The direct grown graphene on n-Si substrate creates a Schottky junction with a potential barrier of 0.44 eV and rectification diode characteristic. Our finding shows that the directly synthesized graphene on Si substrate by a solid phase reaction process can be a promising technique to fabricate an efficient Schottky junction device. (paper)

  2. Development of an interface for directly coupled solid-phase extraction and GC-MS analysis

    NARCIS (Netherlands)

    Öllers, M.J.H.; van Lieshout, H.P.M.; Janssen, J.G.M.; Cramers, C.A.M.G.

    Solid-phase extraction (SPE) is widely used as a sample preparation technique in numerous application areas of chromatography. Large-volume injection is an attractive technique for coupling SPE to gas chromatography (GC) because it provides improved detection limits and circumvents the need for

  3. Solid-phase radioimmunoassay for vitamin B12 in serum, with use of radioiodinated tyrosine methyl ester of vitamin B12

    International Nuclear Information System (INIS)

    Endres, D.B.; Painter, K.; Niswender, G.D.

    1978-01-01

    Although radioassays for vitamin B 12 with use of any of several binding proteins have been available for many years, a radioimmunoassay for B 12 has not been reported. We describe here such a radioimmunoassay, incorporating, for the first time, a radioiodinated tyrosine methyl ester of B 12 as the radioactive tracer. Polypropylene tubes are coated with antiserum raised in a rabbit against B 12 /bovine serum albumin to simplify the separation of bound and free radioactivity. Factors affecting the preparation of coated tubes are described. The assay is accurate, sensitive, precise, and specific for vitamin B 12 . Accuracy of the assay is unaffected by the presence of denatured protein. The advantages of this radioimmunoassay over conventional radioassays are discussed

  4. Preconcentrate of thorium in solid phase and its direct determination by X-ray fluorescence in natural waters

    International Nuclear Information System (INIS)

    Carvalho, Marcelo S. de; Domingues, Maria de Lourdes F.; Mantovano, Jose Luiz; Cunha, Jose Waldemar S.D. da

    2000-01-01

    This paper describe a methodology to pre concentrate thorium from natural water samples by using solid phase extraction (SPE) before its direct determination by X-ray fluorescence. Polyurethane foam supporting 2- ethyl hexyl phosfonic acid was used as SPE. The extraction was maximum at 0.25 mol/L in hydrochloric acid, for 30 minutes of shaking time. At least 8 mg/L thorium could be determined what allowed us to apply this methodology successfully for determination of thorium in natural water reference samples. (author)

  5. Comparison of electron microscopy, enzyme-linked immunosorbent assay, solid-phase radioimmunoassay, and indirect immunofluorescence for detection of human rotavirus antigen in faeces

    Energy Technology Data Exchange (ETDEWEB)

    Birch, C J; Lehmann, N I; Hawker, A J; Marshall, J A; Gust, I D [Fairfield Hospital for Communicable Diseases, Victoria (Australia). Virology Dept.

    1979-07-01

    Four techniques were compared for their practicability, speed, and sensitivity for the detection of human rotavirus. Radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) were found to be the most sensitive means of identifying rotavirus and, once processed, up to 40 specimens could be examined daily. Electron microscopy, although less sensitive than these techniques, had the advantage of being able to detect other viral agents present in faecal extracts. Indirect immunofluorescence failed to detect rotavirus as often as the other three methods. In laboratories where routine examination of faecal specimens from patients with gastroenteritis is required, ELISA and RIA are useful alternatives to electron microscopy.

  6. Comparison of electron microscopy, enzyme-linked immunosorbent assay, solid-phase radioimmunoassay, and indirect immunofluorescence for detection of human rotavirus antigen in faeces

    International Nuclear Information System (INIS)

    Birch, C.J.; Lehmann, N.I.; Hawker, A.J.; Marshall, J.A.; Gust, I.D.

    1979-01-01

    Four techniques were compared for their practicability, speed, and sensitivity for the detection of human rotavirus. Radioimmunoassay (RIA) and enzyme-linked immunosorbent assay (ELISA) were found to be the most sensitive means of identifying rotavirus and, once processed, up to 40 specimens could be examined daily. Electron microscopy, although less sensitive than these techniques, had the advantage of being able to detect other viral agents present in faecal extracts. Indirect immunofluorescence failed to detect rotavirus as often as the other three methods. In laboratories where routine examination of faecal specimens from patients with gastroenteritis is required, ELISA and RIA are useful alternatives to electron microscopy. (author)

  7. A solid phase micro-radioimmunoassay to detect minute amounts of Ig class specific anti-viral antibody in a mouse model system

    International Nuclear Information System (INIS)

    Charlton, D.; Blandford, G.; Toronto Univ., Ontario

    1975-01-01

    A simple and rapid micro-radioimmunoassay was developed to detect and quantitate class specific mouse anti-sendai virus antibodies. Two different 125 I-labelled indicator systems were studied. After incubation of test serum with antigen one system used 125 I-rabbit anti-mouse IgG (RIA 1) and the second employed rabbit anti-mouse IgG, IgA or IgM followed by 125 I-sheep anti-rabbit immunoglobulin reagent (RIA 2). The RIA 2 method was adopted for routine use as it was more sensitive, gave better discrimination between sample and back-ground counts and eliminated the need for several labelled rabbit anti-mouse Ig class specific antisera. The technique was found to be about 100 times more sensitive than conventional HI tests, specific, reliable and economical of reagents and time

  8. Solid-phase enzyme immunoassay or radioimmunoassay for the detection of immune complexes based on their recognition by conglutinin: conglutinin-binding test. A comparative study with /sup 125/I-labelled Clq binding and Raji-cell RIA tests

    Energy Technology Data Exchange (ETDEWEB)

    Casali, P; Bossus, A; Carpentier, N A; Lambert, P H [Hopital Cantonal Geneve (Switzerland)

    1977-01-01

    Bovine conglutinin was used in a solid-phase assay for the detection of immune complexes. In a first step, the tested serum sample was incubated in polypropylene tubes coated with conglutinin to allow C3-coated immune complexes to bind to solid-phase conglutinin. In a second step, the conglutinin-bound complexes were detected using an enzyme-conjugated or radiolabelled anti-immunoglobulin antibody. The conglutinin-binding (KgB) test did not suffer from the interference of DNA, heparin or endotoxins. Its limit of sensitivity for aggregated IgG was 3 ..mu..g/ml undiluted human serum. Immune complexes prepared in vitro using tetanus toxoid, or DNA, and corresponding antibodies in human sera could be detected at various antigen/antibody ratios and at antibody concentrations lower than 8 ..mu..g/ml. The KgB test allowed for the detection of immune complexes in sera from patients with systemic lupus erythematosus, rheumatoid arthritis, idiopathic vasculitis, leprosy and leukemia. These sera were also tested using the /sup 125/I-labelled Clq-binding activity (BA) test and the KgB test simultaneously, and a significant rank order correlation was observed. In patients with leukemia, a significant correlation was observed using three tests, KgB, /sup 125/I-labelled Clq BA and Raji-cell radioimmunoassay (RIA). Therefore, the KgB test appears as a simple and reproducible method, utilizing a very stable reagent, with a sensitivity and specificity comparable to the other tests studied and allowing for clinical application.

  9. Standardization and application of the solid phase C1q radioimmunoassay using soluble tetanus toxoid-antitetanus immune complexes in sera of patients with chronic polyarthritis and Lupus erythematodes

    International Nuclear Information System (INIS)

    Menzel, E.J.; Steffen, C.; Smolen, J.

    1982-01-01

    Soluble tetanus-antitetanus immune complexes were prepared with affinity-chromatography and gel chromatography. Serial dilutions of these immune complex preparations were tested in a solid phase C1q radioimmunoassay. Soluble immune complexes as well as aggregated human gamma globulin of identical protein concentrations were comparatively investigated. Soluble immune complexes rendered a more sensitive standardization of RIA. According to these observations a relation between μg/ml equivalents of defined tetanus-antitetanus complexes and ng second antibody obtained in C1q-RIA was calculated. Upper limit of mean values and two standard deviations of ng second antibody obtained in investigations of 55 normal sera was designated as 1 unit immune complexes and regarded as border line of negative results. Multiplication of μg/ml immune complex equivalents of 1 unit led to a scale of 1 to 15 units, showing the area of positive results. According to these values a standardization curve was constructed allowing a conversion of ng-second antibody obtained in serum investigations into immune complex units equivalent to defined standard immune complexes. With this curve investigation results of 56 RA sera and 21 SLE sera were expressed in the range of units, making a distinct gradation of positive results and a clear cut separation of positive and negative results possible. SLE sera of patients in acute stage showed highly positive results. (orig.) [de

  10. Standardization and application of the solid phase C1q radioimmunoassay using soluble tetanus toxoid-antitetanus immune complexes in sera of patients with chronic polyarthritis and Lupus erythematodes

    Energy Technology Data Exchange (ETDEWEB)

    Menzel, E J; Steffen, C; Smolen, J

    1982-11-22

    Soluble tetanus-antitetanus immune complexes were prepared with affinity-chromatography and gel chromatography. Serial dilutions of these immune complex preparations were tested in a solid phase C1q radioimmunoassay. Soluble immune complexes as well as aggregated human gamma globulin of identical protein concentrations were comparatively investigated. Soluble immune complexes rendered a more sensitive standardization of RIA. According to these observations a relation between ..mu..g/ml equivalents of defined tetanus-antitetanus complexes and ng second antibody obtained in C1q-RIA was calculated. Upper limit of mean values and two standard deviations of ng second antibody obtained in investigations of 55 normal sera was designated as 1 unit immune complexes and regarded as border line of negative results. Multiplication of ..mu..g/ml immune complex equivalents of 1 unit led to a scale of 1 to 15 units, showing the area of positive results. According to these values a standardization curve was constructed allowing a conversion of ng-second antibody obtained in serum investigations into immune complex units equivalent to defined standard immune complexes. With this curve investigation results of 56 RA sera and 21 SLE sera were expressed in the range of units, making a distinct gradation of positive results and a clear cut separation of positive and negative results possible. SLE sera of patients in acute stage showed highly positive results.

  11. Effect of Binding Components in Complex Sample Matrices on Recovery in Direct Immersion Solid-Phase Microextraction: Friends or Foe?

    Science.gov (United States)

    Alam, Md Nazmul; Pawliszyn, Janusz

    2018-02-20

    The development of matrix compatible coatings for solid-phase microextraction (SPME) has enabled direct extraction of analytes from complex sample matrices. The direct immersion (DI) mode of SPME when utilized in conjunction with such extraction phases facilitates extraction of a wide range of analytes from complex matrices without the incurrence of fouling or coating saturation. In this work, mathematical models and computational simulations were employed to investigate the effect of binding components present in complex samples on the recovery of small molecules varying in logP for extractions carried out using the direct immersion approach. The presented findings corroborate that the studied approach indeed enables the extraction of both polar and nonpolar analytes from complex matrices, provided a suitable sorbent is employed. Further results indicated that, in certain cases, the kinetics of extraction of a given analyte in its free form might be dependent on the desorption kinetics of their bound form from matrix components, which might lower total recoveries of analytes with high affinity for the matrix. However, the binding of analytes to matrix components also enables SPME to extract a balanced quantity of different logP analytes, facilitated by multiphase equilibria, with a single extraction device.

  12. Rapid Determination of Clenbuterol in Pork by Direct Immersion Solid-Phase Microextraction Coupled with Gas Chromatography-Mass Spectrometry.

    Science.gov (United States)

    Ye, Diru; Wu, Susu; Xu, Jianqiao; Jiang, Ruifen; Zhu, Fang; Ouyang, Gangfeng

    2016-02-01

    Direct immersion solid-phase microextraction (DI-SPME) coupled with gas chromatography-mass spectrometry (GC-MS) was developed for rapid analysis of clenbuterol in pork for the first time. In this work, a low-cost homemade 44 µm polydimethylsiloxane (PDMS) SPME fiber was employed to extract clenbuterol in pork. After extraction, derivatization was performed by suspending the fiber in the headspace of the 2 mL sample vial saturated with a vapor of 100 µL hexamethyldisilazane. Lastly, the fiber was directly introduced to GC-MS for analysis. All parameters that influenced absorption (extraction time), derivatization (derivatization reagent, time and temperature) and desorption (desorption time) were optimized. Under optimized conditions, the method offered a wide linear range (10-1000 ng g(-1)) and a low detection limit (3.6 ng g(-1)). Finally, the method was successfully applied in the analysis of pork from the market, and recoveries of the method for spiked pork were 97.4-105.7%. Compared with the traditional solvent extraction method, the proposed method was much cheaper and fast. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Direct solid phase microextraction combined with gas chromatography - Mass spectrometry for the determination of biogenic amines in wine.

    Science.gov (United States)

    Papageorgiou, Myrsini; Lambropoulou, Dimitra; Morrison, Calum; Namieśnik, Jacek; Płotka-Wasylka, Justyna

    2018-06-01

    A direct method based on immersion solid phase microextraction (DI-SPME) gas chromatography mass-spectrometry (GC-MS) was optimized and validated for the determination of 16 biogenic amines in Polish wines. In the analysis two internal standards were used: 1,7-diaminoheptane and bis-3-aminopropylamine. The method allows for simultaneous extraction and derivatization, providing a simple and fast mode of extraction and enrichment. Different parameters which affect the extraction procedure were studied and optimized including ionic strength (0-25%), fiber materials (PDMS/DVB, PDMS/DVD + OC, Polyacrylate, Carboxen/PDMS and DVB/CAR/PDMS) and timings of the extraction, derivatization and desorption processes. Validation studies confirmed the linearity, sensitivity, precision and accuracy of the method. The method was successfully applied to the analysis of 44 wine samples originating from several regions of Poland and 3 wine samples from other countries. Analysis showed that many of the samples contained all examined biogenic amines. The method, assessed using an Eco-Scale tool with satisfactory results, was found to be green in terms of hazardous chemicals and solvents usage, energy consumption and production of waste. Therefore the proposed method can be safely used in the wine industry for routine analysis of BAs in wine samples with a minimal detrimental impact on human health and the environment. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. The use of solid sorbents for direct accumulation of organic compounds from water matrices : a review of solid-phase extraction techniques

    NARCIS (Netherlands)

    Liska, I.; Krupcik, J.; Leclercq, P.A.

    1989-01-01

    The main principles of solid-phase extraction techniques are reviewed in this paper. Various solid sorbents can be used as a suitable trap for direct accumulation of organic compounds from aqueous solutions. The trapped analytes can be desorbed by elution with suitably chosen liquid phases. These

  15. Headspace versus direct immersion solid phase microextraction in complex matrixes: investigation of analyte behavior in multicomponent mixtures.

    Science.gov (United States)

    Gionfriddo, Emanuela; Souza-Silva, Érica A; Pawliszyn, Janusz

    2015-08-18

    This work aims to investigate the behavior of analytes in complex mixtures and matrixes with the use of solid-phase microextraction (SPME). Various factors that influence analyte uptake such as coating chemistry, extraction mode, the physicochemical properties of analytes, and matrix complexity were considered. At first, an aqueous system containing analytes bearing different hydrophobicities, molecular weights, and chemical functionalities was investigated by using commercially available liquid and solid porous coatings. The differences in the mass transfer mechanisms resulted in a more pronounced occurrence of coating saturation in headspace mode. Contrariwise, direct immersion extraction minimizes the occurrence of artifacts related to coating saturation and provides enhanced extraction of polar compounds. In addition, matrix-compatible PDMS-modified solid coatings, characterized by a new morphology that avoids coating fouling, were compared to their nonmodified analogues. The obtained results indicate that PDMS-modified coatings reduce artifacts associated with coating saturation, even in headspace mode. This factor, coupled to their matrix compatibility, make the use of direct SPME very practical as a quantification approach and the best choice for metabolomics studies where wide coverage is intended. To further understand the influence on analyte uptake on a system where additional interactions occur due to matrix components, ex vivo and in vivo sampling conditions were simulated using a starch matrix model, with the aim of mimicking plant-derived materials. Our results corroborate the fact that matrix handling can affect analyte/matrix equilibria, with consequent release of high concentrations of previously bound hydrophobic compounds, potentially leading to coating saturation. Direct immersion SPME limited the occurrence of the artifacts, which confirms the suitability of SPME for in vivo applications. These findings shed light into the implementation of in

  16. Solid-phase spectrophotometry

    International Nuclear Information System (INIS)

    Brykina, G.D.; Marchenko, D.Yu.; Shpigun, O.A.

    1995-01-01

    Solid-phase spectrophotometry (SPS), which is based on the direct measurement of light absorption of an ion exchanger containing a substance of interest, was reviewed. Since 1976, it has been known that aborbance of an ion exchanger is directly proportional to the concentration of a particular ion in solution. A similar dependence can also be followed for other sorbents, as well as for foams, membranes, films, etc., which do not exhibit ion exchange properties. One can use absorption, diffuse reflection, and luminescence spectra parameters as an analytical signal. Thus, SPS of ion exchangers is among the analytical techniques that combine the sorption concentration and surface determination of the substance of interest. This review summarizes the advancements in SPS over the last six years and demonstrates the prospects for its development. Special attention is paid to experimental methods for measuring solid-phase absorption and to the basic procedures of sample preparation, including new ones. These two facets are of great importance for obtaining precise results and extending the capabilities of SPS

  17. Direct salivary cortisol radio-immunoassay determination. Clinical applications

    International Nuclear Information System (INIS)

    Simon, C.; Cherfan, J.; Kurtz, F.; Vignon, F.; Schlienger, J.L.; Chabrier, G.

    1987-01-01

    Salivary cortisol levels reflect the biologically active free fraction of blood cortisol. The authors describe the results obtained with the aim of a radio-immunoassay commercial serum cortisol kit, without prealable extraction in different physiological and pathological situations. Salivary cortisol determination appears performant both in nycthemeral studies and in stimulation or freination tests [fr

  18. Unitized solid phase immunoassay kit and method

    International Nuclear Information System (INIS)

    1975-01-01

    A unitized solid phase kit for radioimmunoassay is disclosed. All of the necessary assay reagents are incorporated into a single tube wherein all phases of the assay procedure are performed, requiring only the addition of the patient's sample. Antibody is bound to the tube surface while labelled antigen is also present but unbound. Storage in the absence of air and water results in the stabilization of the reagents such that the system can be stored for long periods

  19. New sensitive direct radioimmunoassay for human plasma renin and its clinical application

    International Nuclear Information System (INIS)

    Higaki, J.; Ogihara, T.; Imai, N.; Kumahara, Y.; Hontani, S.; Nishiura, M.; Ogawa, H.; Hirose, S.; Murakami, K.

    1984-01-01

    A new sensitive direct radioimmunoassay for human plasma renin has been developed. Renin was purified from Haas' preparation utilizing a pepstatin-C 6 -Sepharose affinity chromatography. Antiserum, prepared by immunizing rabbits with the purified renin, was used for the direct radioimmunoassay at a final dilution of 1:30,000. The antibody was specific for human renal and plasma renin, but did not cross-react with cathepsin D, trypsin, or renins of mouse, dog, and rat. Radioimmunoassay was performed by the double antibody technique using the delayed tracer addition method. In this method, a standard curve was obtained over a range from 0.2 to 8.0 ng/ml. The values from this assay correlated well with total renin activity measured as the generation rate of angiotensin I after trypsin activation, but correlated weakly with active renin activity. This finding disclosed that both active and inactive renin were detected by this method. In normal participants, plasma renin concentration determined by direct radioimmunoassay was increased by standing and furosemide injection. The plasma renin concentration determined by direct radioimmunoassay of patients with essential hypertension was not significantly different from values in normal controls. The values were higher in patients with renovascular hypertension, malignant hypertension and Bartter's syndrome, but lower in patients with primary aldosteronism than in normal controls. 20 references, 7 figures

  20. New, advantageous approach to the direct radioimmunoassay of cortisol

    International Nuclear Information System (INIS)

    Tilden, R.L.

    1977-01-01

    Radioimmunoassay of serum cortisol is simplified by a unique solution to the problem of eliminating competition between cortisol-binding globulin and cortisol immunoglobulin. Increasing incubation temperature tends to release cortisol from its carrier protein while favoring the immunoglobulin reaction. We applied this methodology, using reagents supplied as a commercial kit. Serum, 5 μl, is diluted with 125 I-containing tris(hydroxymethyl)aminomethane buffer and incubated at 45 0 C for 1 h, then aspirated. All standards are constituted in steroid-deprived serum. The clinical validity of the method is supported by comparisons with conventional methods during months of use under routine laboratory conditions. The simplified method also offers improved performance characteristics and, as described, is fully instrumented. The significance of this use of thermodynamic properties is discussed in terms of more general applicability

  1. Improved radioimmunoassay for thyroid hormone and reagent

    International Nuclear Information System (INIS)

    1980-01-01

    Improvements in the radioimmunoassay of the thyroid hormones, thyroxine or triiodothyronine, are described. Hydrolyzed cross-linked polyacrylamide particles covalently bonded against the thyroid hormone are employed as solid phase substrates for the thyroid hormone antibodies. The polyacrylamide particles are dyed yellow or blue to facilitate the various manipulative steps during the radioimmunoassay. The particles are characterized by their ability to form stable hydrophilic suspensions. As a result the reaction mixture, during which thyroid hormone is separated from serum proteins and competitive binding in the presence of radioactive tracer with the antibody occurs, requires no agitation to maintain the desired homogeneous condition. This is in contrast to the settling problems experienced with cellulose, dextran and glass particles. In addition, the non-specific binding property of the polyacrylamide particles is so low that the initially separated solid phase particles following incubation can be directly measured for radioactivity levels without any initial washings thus increasing the speed and convenience of the assay procedure. Details of the preparation of the dyed, hydrolyzed polyacrylamide particles, the coupling of antiserum to these particles and the radioimmunoassay procedure are given. Data obtained from the radioimmunoassays of hypothyroid, euthyroid and hyperthyroid sera demonstrated the satisfactory performance of the assay. (U.K.)

  2. Solid-Phase Microextraction Coupled to Capillary Atmospheric Pressure Photoionization-Mass Spectrometry for Direct Analysis of Polar and Nonpolar Compounds.

    Science.gov (United States)

    Mirabelli, Mario F; Zenobi, Renato

    2018-04-17

    A novel capillary ionization source based on atmospheric pressure photoionization (cAPPI) was developed and used for the direct interfacing between solid-phase microextraction (SPME) and mass spectrometry (MS). The efficiency of the source was evaluated for direct and dopant-assisted photoionization, analyzing both polar (e.g., triazines and organophosphorus pesticides) and nonpolar (polycyclic aromatic hydrocarbons, PAHs) compounds. The results show that the range of compound polarity, which can be addressed by direct SPME-MS can be substantially extended by using cAPPI, compared to other sensitive techniques like direct analysis in real time (DART) and dielectric barrier discharge ionization (DBDI). The new source delivers a very high sensitivity, down to sub parts-per-trillion (ppt), making it a viable alternative when compared to previously reported and less comprehensive direct approaches.

  3. Direct observation of solid-phase adsorbate concentration profile in powdered activated carbon particle to elucidate mechanism of high adsorption capacity on super-powdered activated carbon.

    Science.gov (United States)

    Ando, Naoya; Matsui, Yoshihiko; Matsushita, Taku; Ohno, Koichi

    2011-01-01

    Decreasing the particle size of powdered activated carbon (PAC) by pulverization increases its adsorption capacities for natural organic matter (NOM) and polystyrene sulfonate (PSS, which is used as a model adsorbate). A shell adsorption mechanism in which NOM and PSS molecules do not completely penetrate the adsorbent particle and instead preferentially adsorb near the outer surface of the particle has been proposed as an explanation for this adsorption capacity increase. In this report, we present direct evidence to support the shell adsorption mechanism. PAC particles containing adsorbed PSS were sectioned with a focused ion beam, and the solid-phase PSS concentration profiles of the particle cross-sections were directly observed by means of field emission-scanning electron microscopy/energy-dispersive X-ray spectrometry (FE-SEM/EDXS). X-ray emission from sulfur, an index of PSS concentration, was higher in the shell region than in the inner region of the particles. The X-ray emission profile observed by EDXS did not agree completely with the solid-phase PSS concentration profile predicted by shell adsorption model analysis of the PSS isotherm data, but the observed and predicted profiles were not inconsistent when the analytical errors were considered. These EDXS results provide the first direct evidence that PSS is adsorbed mainly in the vicinity of the external surface of the PAC particles, and thus the results support the proposition that the increase in NOM and PSS adsorption capacity with decreasing particle size is due to the increase in external surface area on which the molecules can be adsorbed. Copyright © 2010 Elsevier Ltd. All rights reserved.

  4. Direct modification of hydrogen/deuterium-terminated diamond particles with polymers to form reversed and strong cation exchange solid phase extraction sorbents.

    Science.gov (United States)

    Yang, Li; Jensen, David S; Vail, Michael A; Dadson, Andrew; Linford, Matthew R

    2010-12-03

    We describe direct polymer attachment to hydrogen and deuterium-terminated diamond (HTD and DTD) surfaces using a radical initiator (di-tert-amyl peroxide, DTAP), a reactive monomer (styrene) and a crosslinking agent (divinylbenzene, DVB) to create polystyrene encapsulated diamond. Chemisorbed polystyrene is sulfonated with sulfuric acid in acetic acid. Surface changes were followed by X-ray photoelectron spectroscopy (XPS), time-of-flight secondary ion mass spectrometry (ToF-SIMS) and diffuse reflectance Fourier transform infrared spectroscopy (DRIFT). Finally, both polystyrene-modified DTD and sulfonated styrene-modified DTD were used in solid phase extraction (SPE). Percent recovery and column capacity were investigated for both phenyl (polystyrene) and sulfonic acid treated polystyrene SPE columns. These diamond-based SPE supports are stable under basic conditions, which is not the case for silica-based SPE supports. Copyright © 2010. Published by Elsevier B.V.

  5. Ultrasensitive radioimmunoassay for direct determination of free triiodothyronine concentration in serum

    International Nuclear Information System (INIS)

    Weeke, J.; Oerskov, H.

    1975-01-01

    Free triiodothyronine (T 3 ) in serum has been measured directly in dialysates of serum, using a wick chromatographic radioimmunoassay. Adequate sensitivity was attained by the use of [ 125 I]T 3 with a very high specific activity (2,000 to 3,000μCi/μg). Sera were dialysed against a Krebs-Ringer bicarbonate buffer modified so as to be similar to plasma water. Dialysis took place under carefully controlled circumstances. The influence on the equilibrium of total to free T 3 of temperature, serum dilution and dialysis time was studied. By the present method, free T 3 in serum from groups of subjects including 20 men, 10 women taking oral contraceptives and 20 women with normal menstrual cycles were identical, averaging 5.2 pg/ml. A chromatographic radioimmunoassay of total T 3 using high specific activity [ 125 I]T 3 and a very small test sample is also described. (auth.)

  6. Solid phase extraction membrane

    Science.gov (United States)

    Carlson, Kurt C [Nashville, TN; Langer, Roger L [Hudson, WI

    2002-11-05

    A wet-laid, porous solid phase extraction sheet material that contains both active particles and binder and that possesses excellent wet strength is described. The binder is present in a relatively small amount while the particles are present in a relatively large amount. The sheet material is sufficiently strong and flexible so as to be pleatable so that, for example, it can be used in a cartridge device.

  7. Measurement of antibodies to tubulin by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Mead, G M; Cowin, P; Whitehouse, J M.A. [CRC Medical Oncology Unit, Southampton General Hospital, Southampton, U.K.

    1979-07-24

    A solid-phase double antibody radioimmunoassay capable of measuring antibody to tubulin, the principal component of microtubules, is described. This assay is simple, combining sensitivity with specificity and also allowing determination of antibody subclasses.

  8. Fast analysis of glycosides based on HKUST-1-coated monolith solid-phase microextraction and direct analysis in real-time mass spectrometry.

    Science.gov (United States)

    Li, Xianjiang; Wang, Xin; Ma, Wen; Ai, Wanpeng; Bai, Yu; Ding, Li; Liu, Huwei

    2017-04-01

    Glycosides are a kind of highly important natural aromatic precursors in tobacco leaves. In this study, a novel HKUST-1-coated monolith dip-it sampler was designed for the fast and sensitive analysis of trace glycosides using direct analysis in real-time mass spectrometry. This device was prepared in two steps: in situ polymerization of monolith in a glass capillary of dip-it and layer-by-layer growth of HKUST-1 on the surface of monolith. Sufficient extraction was realized by immersing the tip to solution and in situ desorption was carried out by plasma direct analysis in real time. Compared with traditional solid-phase microextraction protocols, sample desorption was not needed anymore, and only extraction conditions were needed to be optimized in this method, including the gas temperature of direct analysis in real time, extraction time, and CH 3 COONH 4 additive concentration. This method enabled the simultaneous detection of six kinds of glycosides with the limits of detection of 0.02-0.05 μg/mL and the linear ranges covering two orders of magnitude with the limits of quantitation of 0.05-0.1 μg/mL. Moreover, the developed method was applied for the glycosides analysis of three tobacco samples, which only took about 2 s for every sample. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  10. Solid phase transformations

    CERN Document Server

    Čermák, J

    2008-01-01

    This special-topic book, devoted to ""Solid Phase Transformations"" , covers a broad range of phenomena which are of importance in a number of technological processes. Most commercial alloys undergo thermal treatment after casting, with the aim of imparting desired compositions and/or optimal morphologies to the component phases. In spite of the fact that the topic has lain at the center of physical metallurgy for a long time, there are numerous aspects which are wide open to potential investigative breakthroughs. Materials with new structures also stimulate research in the field, as well as n

  11. Determination of strontium-90 from direct separation of yttrium-90 by solid phase extraction using DGA Resin for seawater monitoring.

    Science.gov (United States)

    Tazoe, Hirofumi; Obata, Hajime; Yamagata, Takeyasu; Karube, Zin'ichi; Nagai, Hisao; Yamada, Masatoshi

    2016-05-15

    It is important for public safety to monitor strontium-90 in aquatic environments in the vicinity of nuclear related facilities. Strontium-90 concentrations in seawater exceeding the background level have been observed in accidents of nuclear facilities. However, the analytical procedure for measuring strontium-90 in seawater is highly demanding. Here we show a simple and high throughput analytical technique for the determination of strontium-90 in seawater samples using a direct yttrium-90 separation. The DGA Resin is used to determine the abundance of strontium-90 by detecting yttrium-90 decay (beta-emission) in secular equilibrium. The DGA Resin can selectively collect yttrium-90 and remove naturally occurring radionuclides such as (40)K, (210)Pb, (214)Bi, (238)U, and (232)Th and anthropogenic radionuclides such as (140)Ba, and (140)La. Through a sample separation procedure, a high chemical yield of yttrium-90 was achieved at 95.5±2.3%. The result of IAEA-443 certified seawater analysis (107.7±3.4 mBq kg(-1)) was in good agreement with the certified value (110±5 mBq kg(-1)). By developed method, we can finish analyzing 8 samples per day after achieving secular equilibrium, which is a reasonably fast throughput in actual seawater monitoring. By processing 3 L of seawater sample and applying a counting time of 20 h, minimum detectable activity can be as low as 1.5 mBq kg(-1), which could be applied to monitoring for the contaminated marine environment. Reproducibility was found to be 3.4% according to 10 independent analyses of natural seawater samples from the vicinity of the Fukushima Daiichi Nuclear Power Plant in September 2013. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Beating Bias in the Directed Evolution of Proteins: Combining High-Fidelity on-Chip Solid-Phase Gene Synthesis with Efficient Gene Assembly for Combinatorial Library Construction.

    Science.gov (United States)

    Li, Aitao; Acevedo-Rocha, Carlos G; Sun, Zhoutong; Cox, Tony; Xu, Jia Lucy; Reetz, Manfred T

    2018-02-02

    Saturation mutagenesis (SM) constitutes a widely used technique in the directed evolution of selective enzymes as catalysts in organic chemistry and in the manipulation of metabolic paths and genomes, but the quality of the libraries is far from optimal due to the inherent amino acid bias. Herein, it is shown how this fundamental problem can be solved by applying high-fidelity solid-phase chemical gene synthesis on silicon chips followed by efficient gene assembly. Limonene epoxide hydrolase was chosen as the catalyst in the model desymmetrization of cyclohexene oxide with the stereoselective formation of (R,R)- and (S,S)-cyclohexane-1,2-diol. A traditional combinatorial PCR-based SM library, produced by simultaneous randomization at several residues by using a reduced amino acid alphabet, and the respective synthetic library were constructed and compared. Statistical analysis at the DNA level with massive sequencing demonstrates that, in the synthetic approach, 97 % of the theoretically possible DNA mutants are formed, whereas the traditional SM library contained only about 50 %. Screening at the protein level also showed the superiority of the synthetic library; many highly (R,R)- and (S,S)-selective variants being discovered are not found in the traditional SM library. With the prices of synthetic genes decreasing, this approach may point the way to future directed evolution. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Determination of phthalate esters in vegetable oils using direct immersion solid-phase microextraction and fast gas chromatography coupled with triple quadrupole mass spectrometry.

    Science.gov (United States)

    Barp, Laura; Purcaro, Giorgia; Franchina, Flavio A; Zoccali, Mariosimone; Sciarrone, Danilo; Tranchida, Peter Q; Mondello, Luigi

    2015-08-05

    Phthalates are a group of synthetic compounds mainly used as plasticizers, which have been classified as endocrine-disrupting chemicals and potential human-cancer causing agents. They can be found in high amounts in foods, deriving mainly from plastic packaging. The analytical determination of these compounds is very challenging since they are ubiquitous. Therefore, minimization of sample manipulation is highly desirable. The present work exploited the application of a solid-phase microextraction method for the analysis of phthalates in vegetable oil. A preliminary comparison between a polydimethylsiloxane (PDMS) and a Carbopack Z/PDMS fiber was carried out both in the headspace and direct immersion extraction modes. Before immersing the fiber, a rapid liquid-liquid extraction was performed using acetonitrile to remove the bulk of triglycerides. PDMS in the direct immersion mode showed the best performance. The method was fully validated obtaining a good linearity with a coefficient of correlation of over 0.9960 for all compounds, repeatability and accuracy values generally better than 10%, and very good limit of quantification values. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Determination of ibuprofen enantiomers in breast milk using vortex-assisted matrix solid-phase dispersion and direct chiral liquid chromatography.

    Science.gov (United States)

    León-González, M E; Rosales-Conrado, N

    2017-09-08

    A mixture of β-cyclodextrin (β-CD) and primary and secondary amine (PSA) sorbents was employed for the extraction and quantification of ibuprofen enantiomers from human breast milk, combining a vortex-assisted matrix solid-phase dispersion method (MSPD) and direct chiral liquid chromatography (CLC) with ultraviolet detection (UV). The MSPD sample preparation procedure was optimized focusing on both the type and amount of dispersion/sorption sorbents and the nature of the elution solvent, in order to obtain acceptable recoveries and avoiding enantiomer conversion. These MSPD parameters were optimized with the aid of an experimental design approach. Hence, a factorial design was used for identification of the main variables affecting the extraction process of ibuprofen enantiomers. Under optimum selected conditions, MSPD combined with direct CLC-UV was successfully applied for ibuprofen enantiomeric determination in breast milk at enantiomer levels between 0.15 and 6.0μgg -1 . The proposed analytical method also provided good repeatability, with relative standard deviations of 6.4% and 8.3% for the intra-day and inter-day precision, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Reliability of pregnancy diagnosis in sows by direct radioimmunoassay of estrone sulfate

    International Nuclear Information System (INIS)

    Kalab, P.; Hajek, J.

    1988-01-01

    Pregnancy diagnosis in sows using direct radioimmunoassay of estrone sulfate in the blood serum without sample extraction is described. It was found that for pregnancy diagnosis the period between days 22 and 30 of pregnancy can be used since in this period the estrone sulfate concentrations in all pregnant sows markedly exceeded those of 64 non-pregnant animals. The estrone sulfate estimation cannot be used for pregnancy diagnosis before day 22 and between days 30 and 40 because the estrone sulfate concentrations in most samples collected in these periods were lower than 4 nmol.l -1 . (author). 1 fig., 6 refs

  16. A direct radio-immunoassay for plasma aldosterone: significance of endogenous cortisol

    International Nuclear Information System (INIS)

    Man, A.J.M. de; Hofman, J.A.; Hendriks, Th.; Rosmalen, F.M.A.; Ross, H.A.; Benraad, Th.J.

    1980-01-01

    A direct radio-immunoassay for plasma aldosterone was developed, using a highly specific antiserum raised in sheep. An excellent correlation was observed between its results and the levels measured after extraction and chromatography. The necessity of including a blocking agent to inhibit the binding of aldosterone to plasma proteins was investigated. It was found that in low-cortisol ( 10 μg/100 ml) the final assay result was independent of the presence of ANS. The effect of cortisol was interpreted in terms of its influence on aldosterone binding to plasma proteins in the absence of a blocking agent. (Auth.)

  17. High throughput screening of phenoxy carboxylic acids with dispersive solid phase extraction followed by direct analysis in real time mass spectrometry.

    Science.gov (United States)

    Wang, Jiaqin; Zhu, Jun; Si, Ling; Du, Qi; Li, Hongli; Bi, Wentao; Chen, David Da Yong

    2017-12-15

    A high throughput, low environmental impact methodology for rapid determination of phenoxy carboxylic acids (PCAs) in water samples was developed by combing dispersive solid phase extraction (DSPE) using velvet-like graphitic carbon nitride (V-g-C 3 N 4 ) and direct analysis in real time mass spectrometry (DART-MS). Due to the large surface area and good dispersity of V-g-C 3 N 4 , the DSPE of PCAs in water was completed within 20 s, and the elution of PCAs was accomplished in 20 s as well using methanol. The eluents were then analyzed and quantified using DART ionization source coupled to a high resolution mass spectrometer, where an internal standard was added in the samples. The limit of detection ranged from 0.5 ng L -1 to 2 ng L -1 on the basis of 50 mL water sample; the recovery 79.9-119.1%; and the relative standard deviation 0.23%-9.82% (≥5 replicates). With the ease of use and speed of DART-MS, the whole protocol can complete within mere minutes, including sample preparation, extraction, elution, detection and quantitation. The methodology developed here is simple, fast, sensitive, quantitative, requiring little sample preparation and consuming significantly less toxic organic solvent, which can be used for high throughput screening of PCAs and potentially other contaminants in water. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Application of headspace and direct immersion solid-phase microextraction in the analysis of organothiophosphates related to the Chemical Weapons Convention from water and complex matrices.

    Science.gov (United States)

    Althoff, Marc André; Bertsch, Andreas; Metzulat, Manfred; Klapötke, Thomas M; Karaghiosoff, Konstantin L

    2017-11-01

    The successful application of headspace (HS) and direct immersion (DI) solid phase microextraction (SPME) for the unambiguous identification and characterization of a series of toxic thiophosphate esters, such as Amiton (I), from aqueous phases and complex matrices (e.g. grass and foliage) has been demonstrated. A Thermo Scientific gas chromatograph (GC) - tandem mass spectrometer (MS/MS) system with a TriPlus RSH® autosampler and a SPME tool was used to investigate the effect of different parameters that influence the extraction efficiency: e.g. pH of the sample matrix and extraction temperature. The developed methods were employed for the detection of several Amiton derivatives (Schedule II of the CWC) that are structurally closely related to each other; some of which are new and have not been reported in literature previously. In addition, a novel DI SPME method from complex matrices for the analysis of organophosphates related to the CWC was developed. The studies clearly show that DI SPME for complex matrices is superior to HS extraction and can potentially be applied to other related compounds controlled under the CWC. Copyright © 2017. Published by Elsevier B.V.

  19. Development of a polymeric ionic liquid coating for direct-immersion solid-phase microextraction using polyhedral oligomeric silsesquioxane as cross-linker.

    Science.gov (United States)

    Chen, Chunyan; Liang, Xiaotong; Wang, Jianping; Zou, Ying; Hu, Huiping; Cai, Qingyun; Yao, Shouzhuo

    2014-06-27

    A novel solid-phase microextraction (SPME) fiber was developed by chemical binding of a crosslinked polymeric ionic liquid (PIL) on the surface of an anodized Ti wire, and was applied in direct-immersion mode for the extraction of perfluorinated compounds (PFCs) from water samples coupled with high performance liquid chromatography-tandem mass spectrometry analysis. The PIL coatings were synthesized by using 1-vinyl-3-hexylimidazolium hexafluorophosphate as monomer and methylacryloyl-substituted polyhedral oligomeric silsesquioxane (POSS) as cross-linker via free radical reaction. The proposed fiber coating exhibited high mechanical stability due to the chemical bonding between the coating and the Ti wire surface. The integration of POSS reagent enhanced the organic solvent resistance of the coating. The parameters affecting the extraction performance of the fiber coating including extraction time, pH of solution, ionic strength and desorption conditions were optimized. The developed PIL-POSS fiber showed good linearity (R<0.998) between 0.1 and 50ngmL(-1) with method detection limits ranging from 0.005 to 0.08ngmL(-1) depending on the analyte, and with relative standard deviation for single-fiber repeatability and fiber-to-fiber reproducibility less than 8.6% and 9.5%, respectively. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Solid phase syntheses of oligoureas

    Energy Technology Data Exchange (ETDEWEB)

    Burgess, K.; Linthicum, D.S.; Russell, D.H.; Shin, H.; Shitangkoon, A.; Totani, R.; Zhang, A.J.; Ibarzo, J. [Texas A& M Univ., College Station, TX (United States)

    1997-02-19

    Isocyanates 7 were formed from monoprotected diamines 3 or 6, which in turn can be easily prepared from commercially available N-BOC- or N-FMOC-protected amino acid derivatives. Isocyanates 7, formed in situ, could be coupled directly to a solid support functionalized with amine groups or to amino acids anchored on resins using CH{sub 2}Cl{sub 2} as solvent and an 11 h coupling time at 25 {degree}C. Such couplings afforded peptidomimetics with an N-phthaloyl group at the N-terminus. The optimal conditions identified for removal of the N-phthaloyl group were to use 60% hydrazine in DMF for 1-3 h. Several sequences of amino acids coupled to ureas (`peptidic ureas`) and of sequential urea units (`oligoureas`) were prepared via solid phase syntheses and isolated by HPLC. Partition coefficients were measured for two of these peptidomimetics, and their water solubilities were found to be similar to the corresponding peptides. A small library of 160 analogues of the YGGFL-amide sequence was prepared via Houghten`s tea bag methodology. This library was tested for binding to the anti-{beta}-endorphin monoclonal antibody. Overall, this paper describes methodology for solid phase syntheses of oligourea derivatives with side chains corresponding to some of the protein amino acids. The chemistry involved is ideal for high-throughput syntheses and screening operations. 51 refs., 3 figs., 2 tabs.

  1. Solid phase microextraction.

    Science.gov (United States)

    Pawliszyn, J

    2001-01-01

    Solid Phase Microextraction (SPME) uses a small volume of sorbent dispersed typically on the surface of small fibres, to isolate and concentrate analytes from sample matrix. After contact with sample, analytes are absorbed or adsorbed by the fibre phase (depending on the nature of the coating) until an equilibrium is reached in the system. The amount of an analyte extracted by the coating at equilibrium is determined by the magnitude of the partition coefficient of the analyte between the sample matrix and the coating material. After the extraction step, the fibres are transferred, with the help of a syringe-like handling device, to analytical instrument, for separation and quantitation of target analytes. This technique integrates sampling, extraction and sample introduction and is a simple way of facilitating on-site monitoring. Applications of this technique include environmental monitoring, industrial hygiene, process monitoring, clinical, forensic, food, flavour, fragrance and drug analyses, in laboratory and on-site analysis.

  2. Solid-phase microextraction

    DEFF Research Database (Denmark)

    Nilsson, Torben

    The objective of this study has been to develop new analytical methods using the rapid, simple and solvent-free extraction technique solid-phase microextraction (SPME) for the quantitative analysis of organic pollutants at trace level in drinking water and environmental samples. The dynamics...... of SPME were examined for halogenated and non-halogenated volatile hydrocarbons, and a standard method for their quantitative analysis in aqueous samples was developed and validated in inter-laboratory studies on the basis of reference material and in comparison with the traditional methods....... The influences of some possible interferences on the SPME process were examined, and new SPME probes were tested for the in situ monitoring of groundwater pollutants. Inter-laboratory studies were carried out also for the validation of SPME for the quantitative analysis of organochlorine, organonitrogen...

  3. A four-step sandwich radioimmunoassay for direct selection of monoclonal antibodies to allergen molecules

    International Nuclear Information System (INIS)

    Ley, V.; Corbi, A.L.; Sanchez-Madrid, F.; Carreira, J.C.

    1985-01-01

    A 4-step radioimmunoassay has been devised for direct identification of monoclonal antibodies (MAb) directed to IgE-binding molecules. Polyvinyl chloride wells coated with purified anti-mouse kappa chain MAb (187-1) were successively incubated with: (1) MAb-containing hybridoma supernatants, (2) allergen extract, (3) allergic patients' serum pool, and (4) 125 I-labeled anti-human IgE antiserum, to detect MAb-allergen-IgE complexes. MAb to allergens from Parietaria judaica pollen and Dermatophagoides mites have been selected with this screening procedure. The affinity-purified allergen molecules competed the binding of IgE to allergen extracts coated to paper discs in a RAST inhibition assay, confirming the anti-allergen specificity of the selected MAb. This screening method is sensitive enough to allow detection of MAb directed to poorly represented allergens. (Auth.)

  4. Direct determination of enthalpies of solid phase reactions by immersion method; Determination directe des enthalpies de reaction en phase solide par une methode de plongee

    Energy Technology Data Exchange (ETDEWEB)

    Roux, A; Richard, M; Eyraud, L; Stevanovic, M; Elston, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    It is not generally possible to measure the enthalpy change corresponding to solid phase reactions using the dynamic differential thermal analysis method because these reactions are usually too slow at the temperature of operation of present equipment. A ballistic differential thermal analysis apparatus has been developed which is based on an immersion-compensation method; it overcomes the difficulties previously encountered. This apparatus has been used after calibration for determining the enthalpies of formation of calcium and cadmium titanates. and also the Wigner energies of BeO, MgO and Al{sub 2}O{sub 3} samples irradiated at variable dose at a temperature of under 100 deg. C. (authors) [French] Il n'est generalement pas possible de mesurer la variation d'enthalpie correspondant aux reactions en phase solide par la methode d'analyse thermique differentielle dynamique. En effet, ces reactions sont le plus souvent trop lentes aux temperatures d'utilisation des dispositifs actuels. Un appareil d'analyse thermique differentielle balistique, base sur une methode de plongee avec compensation, a ete mis au point et permet de surmonter les difficultes precedentes. Apres etalonnages, cet appareil a ete utilise pour la determination des enthalpies de formation du titanate de calcium et du titanate de cadmium ainsi que pour celle des energies Wigner emmagasinees dans des echantillons de BeO, MgO et Al{sub 2}O{sub 3} irradies a une temperature inferieure a 100 deg. C et a differentes doses. (auteurs)

  5. Hormonal monitoring of early pregnancy by a direct radioimmunoassay of steroid glucuronides in first morning urine

    Energy Technology Data Exchange (ETDEWEB)

    Mendizabal, A.F.; Quiroga, S.; Farinati, Z.; Lahoz, M.; Nagle, C.

    1984-11-01

    The usefulness of the direct 4-hour radioimmunoassay of estriol-16-glucuronide (E/sub 3/G) and pregnanediol-3-glucuronide (P/sub 2/G) in first morning urine (FMU) for establishing a prognosis of the early pregnancy outcome was evaluated in 106 patients that became pregnant. Microaliquots of FMU were serially assayed from day 3 of the conception cycle until day 80 of pregnancy. The E/sub 3/G and P/sub 2/G profiles of 19 pregnancies which terminated in spontaneous abortion with either a diagnosis of the blighted ovum syndrome (n = 11) or presumption of a corpus luteum/trophoblast failure (n = 8) have been compared with those of clinically normal pregnancies (n = 87). Normal pregnancies displayed typical patterns of E/sub 3/G and P/sub 2/G development, while variations were observed in abortive events that reflected changes of the fetoplacental unit.

  6. Iodine-125 radioimmunoassay for the direct detection of benzodiazepines in blood and urine

    Energy Technology Data Exchange (ETDEWEB)

    Goddard, C.P.; Stead, A.H.; Mason, P.A.; Law, B.; Moffat, A.C.; McBrien, M.; Cosby, S.

    1986-05-01

    A radioimmunoassay (RIA) for the direct detection of benzodiazepines in blood and urine is described. It is based on a commercially available antiserum and an easily synthesised radio-iodinated derivative of clonazepam that allows the use of relatively simple gamma-counting procedures. The assay can detect low therapeutic levels of all of the benzodiazepines currently available in the UK in 50-..mu..l samples of blood and urine (1-50 ng ml/sup -1/, depending on the drug); no prior sample preparation is required. It is inexpensive, rapid, simple to perform and is broadly specific for the benzodiazepine class of drugs. The assay offers a most suitable means of screening large numbers of samples of forensic interest for the presence of the benzodiazepines.

  7. Hormonal monitoring of early pregnancy by a direct radioimmunoassay of steroid glucuronides in first morning urine

    International Nuclear Information System (INIS)

    Mendizabal, A.F.; Quiroga, S.; Farinati, Z.; Lahoz, M.; Nagle, C.

    1984-01-01

    The usefulness of the direct 4-hour radioimmunoassay of estriol-16-glucuronide (E 3 G) and pregnanediol-3-glucuronide (P 2 G) in first morning urine (FMU) for establishing a prognosis of the early pregnancy outcome was evaluated in 106 patients that became pregnant. Microaliquots of FMU were serially assayed from day 3 of the conception cycle until day 80 of pregnancy. The E 3 G and P 2 G profiles of 19 pregnancies which terminated in spontaneous abortion with either a diagnosis of the blighted ovum syndrome (n = 11) or presumption of a corpus luteum/trophoblast failure (n = 8) have been compared with those of clinically normal pregnancies (n = 87). Normal pregnancies displayed typical patterns of E 3 G and P 2 G development, while variations were observed in abortive events that reflected changes of the fetoplacental unit

  8. An iodine-125 radioimmunoassay for the direct detection of benzodiazepines in blood and urine

    International Nuclear Information System (INIS)

    Goddard, C.P.; Stead, A.H.; Mason, P.A.; Law, B.; Moffat, A.C.; McBrien, M.; Cosby, S.

    1986-01-01

    A radioimmunoassay (RIA) for the direct detection of benzodiazepines in blood and urine is described. It is based on a commercially available antiserum and an easily synthesised radio-iodinated derivative of clonazepam that allows the use of relatively simple gamma-counting procedures. The assay can detect low therapeutic levels of all of the benzodiazepines currently available in the UK in 50-μl samples of blood and urine (1-50 ng ml -1 , depending on the drug); no prior sample preparation is required. It is inexpensive, rapid, simple to perform and is broadly specific for the benzodiazepine class of drugs. The assay offers a most suitable means of screening large numbers of samples of forensic interest for the presence of the benzodiazepines. (author)

  9. Direct radioimmunoassay of proinsulin and insulin in human plasma by the chromatographic technique

    Energy Technology Data Exchange (ETDEWEB)

    Megahed, Y M; Abdel-Wahab, M F; El-Shawarbie, K; Sadek, S; Amer, M S [Atomic Energy Establishment, Cairo (Egypt). Radioisotope Department; Ain Shams Univ., Cairo (Egypt). Faculty of Medicine)

    1976-04-01

    Specific method for direct radioimmunoassay of IRP and IRI separately in human plasma has been described. The method is used for extraction of total insulin and separation of IRP from IRI by paper chromatography to be assayed separately. The separation of the two components is identified and confirmed by column chromatography, paper chromatography and ultraviolet spectral analysis in comparison with the standard compounds. 134 plasma samples of different cases were investigated for the determination of IRI, IRP and IRT. Out of these 39 were normals, 16 normal obes, 21 juvinil diabetes, 18 overt adult diabetes, 10 recent adult diabetes, 12 hypothyroidism and 18 bilharzial hepatosplenomegaly. They were used to evaluate the test levels in comparison with blood sugar concentration.

  10. Direct Zinc Determination in Brazilian Sugar Cane Spirit by Solid-Phase Extraction Using Moringa oleifera Husks in a Flow System with Detection by FAAS

    OpenAIRE

    Alves, Vanessa N.; Borges, Simone S. O.; Coelho, Nivia M. M.

    2011-01-01

    This paper reports a method for the determination of zinc in Brazilian sugar cane spirit, (cachaça in Portuguese), using solid-phase extraction with a flow injection analysis system and detection by FAAS. The sorbent material used was activated carbon obtained from Moringa oleifera husks. Flow and chemical variables of the proposed system were optimized through multivariate designs. The factors selected were sorbent mass, sample pH, sample flow rate, and eluent concentration. The optimum extr...

  11. Automated direct-immersion solid-phase microextraction using crosslinked polymeric ionic liquid sorbent coatings for the determination of water pollutants by gas chromatography.

    Science.gov (United States)

    Cordero-Vaca, María; Trujillo-Rodríguez, María J; Zhang, Cheng; Pino, Verónica; Anderson, Jared L; Afonso, Ana M

    2015-06-01

    Four different crosslinked polymeric ionic liquid (PIL)-based sorbent coatings were evaluated in an automated direct-immersion solid-phase microextraction method (automated DI-SPME) in combination with gas chromatography (GC). The crosslinked PIL coatings were based on vinyl-alkylimidazolium- (ViCnIm-) or vinylbenzyl-alkylimidazolium- (ViBzCnIm-) IL monomers, and di-(vinylimidazolium)dodecane ((ViIm)2C12-) or di-(vinylbenzylimidazolium)dodecane ((ViBzIm)2C12-) dicationic IL crosslinkers. In addition, a PIL-based hybrid coating containing multi-walled carbon nanotubes (MWCNTs) was also studied. The studied PIL coatings were covalently attached to derivatized nitinol wires and mounted onto the Supelco assembly to ensure automation when acting as SPME coatings. Their behavior was evaluated in the determination of a group of water pollutants, after proper optimization. A comparison was carried out with three common commercial SPME fibers. It was observed that those PILs containing a benzyl group in their structures, either in the IL monomer and crosslinker (PIL-1-1) or only in the crosslinker (PIL-0-1), were the most efficient sorbents for the selected analytes. The validation of the overall automated DI-SPME-GC-flame ionization detector (FID) method gave limits of detection down to 135 μg · L(-1) for p-cresol when using the PIL-1-1 and down to 270 μg · L(-1) when using the PIL-0-1; despite their coating thickness: ~2 and ~5 μm, respectively. Average relative recoveries with waters were of 85 ± 14 % and 87 ± 15 % for PIL-1-1 and PIL-0-1, respectively. Precision values as relative standard deviation were always lower than 4.9 and 7.6 % (spiked level between 10 and 750 μg · L(-1), as intra-day precision). Graphical Abstract Automated DI-SPME-GC-FID using crosslinked-PILs sorbent coatings for the determination of waterpollutants.

  12. Parameters optimization using experimental design for headspace solid phase micro-extraction analysis of short-chain chlorinated paraffins in waters under the European water framework directive.

    Science.gov (United States)

    Gandolfi, F; Malleret, L; Sergent, M; Doumenq, P

    2015-08-07

    The water framework directives (WFD 2000/60/EC and 2013/39/EU) force European countries to monitor the quality of their aquatic environment. Among the priority hazardous substances targeted by the WFD, short chain chlorinated paraffins C10-C13 (SCCPs), still represent an analytical challenge, because few laboratories are nowadays able to analyze them. Moreover, an annual average quality standards as low as 0.4μgL(-1) was set for SCCPs in surface water. Therefore, to test for compliance, the implementation of sensitive and reliable analysis method of SCCPs in water are required. The aim of this work was to address this issue by evaluating automated solid phase micro-extraction (SPME) combined on line with gas chromatography-electron capture negative ionization mass spectrometry (GC/ECNI-MS). Fiber polymer, extraction mode, ionic strength, extraction temperature and time were the most significant thermodynamic and kinetic parameters studied. To determine the suitable factors working ranges, the study of the extraction conditions was first carried out by using a classical one factor-at-a-time approach. Then a mixed level factorial 3×2(3) design was performed, in order to give rise to the most influent parameters and to estimate potential interactions effects between them. The most influent factors, i.e. extraction temperature and duration, were optimized by using a second experimental design, in order to maximize the chromatographic response. At the close of the study, a method involving headspace SPME (HS-SPME) coupled to GC/ECNI-MS is proposed. The optimum extraction conditions were sample temperature 90°C, extraction time 80min, with the PDMS 100μm fiber and desorption at 250°C during 2min. Linear response from 0.2ngmL(-1) to 10ngmL(-1) with r(2)=0.99 and limits of detection and quantification, respectively of 4pgmL(-1) and 120pgmL(-1) in MilliQ water, were achieved. The method proved to be applicable in different types of waters and show key advantages, such

  13. Multiplexed Colorimetric Solid-Phase Extraction

    Science.gov (United States)

    Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.

    2009-01-01

    Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).

  14. Androgen radioimmunoassay in the ram: results of direct plasma testosterone and dehydroepiandrosterone measurement and physiological evaluation

    International Nuclear Information System (INIS)

    Garnier, D.-H.; Cotta, Y.; Terqui, M.

    1978-01-01

    Different radioimmunoassays of testosterone (T) dehydroepiandrosterone (DHA) and 5 α-dihydrotestosterone (5 α-DHT) were investigated for ram plasma. Specificity of the antisera, lack of noticeable binding in plasma, very low levels of other androgens allow direct plasma RIA for DHA and T by the double antibody technique. The levels obtained by this simplified method are in agreement with those found after extraction alone, after extraction and celite chromatography and after quantification with a completely different technique such as gas chromatography. The within assay variabilities for T and DHA were 4.7 p. 100 and 4.6 p. 100 respectively but vary with the level of steroid in plasma. The inter assay variabilities of T were 9.5 p. 100 and 3.2 p. 100 for 1.5 and 11.6 ng/ml of plasma respectively. The antiserum for 5 α-DHT have a specificity such that, even after celite chromatography some androgens (5 β-DHT) may interfere. However determinations of 5 α/5 β-DHT amounts are possible. The physiological validations of direct plasma T and DHA RIA were studied in various conditions. The DHA plasma variations are similar to those of T in Ram from birth to puberty, but the levels are lower. DHA plasma levels show a seasonal variation as does testosterone. Variations within 24 hrs of these two androgens were in synchrony. The direct plasma T and DHA assays are useful and inexpensive tools to characterize ram testicular function

  15. Free thyroxin by radioimmunoassay: evaluation of a new direct method involving a radiolabeled thyroxin analog

    International Nuclear Information System (INIS)

    Kubasik, N.P.; Lundberg, P.A.; Brodows, R.G.; Hallauer, G.D.; Same, D.G.; Lindstedt, G.; Bengtsson, C.; Nystroem, E.

    1983-01-01

    The first performance evaluation of a new direct method for free thyroxin (T4) in serum by radioimmunoassay, with use of coated tubes and a radioiodinated T4 analog (Diagnostic Products Corp.) is presented. The assay is precise and robust: within-run imprecision (CV), 3.1-6.6%; between-run imprecision, 4.0-7.9%; no demonstrable variation between technologists irrespective of experience with the method. No outliers were observed when we compared the free T4 results with serum total T4. Reference values are reported for a total of 1243 euthyroid subjects; there was no significant age effect on serum free T4 in women 26 to 72 years old. The biological variation was about +/- 35% of the mean (2 SD). Free T4 results are the same for serum and plasma. The assay performs well in hypothyroidism and hyperthyroidism, and distinguishes individuals with thyroid disease from normal individuals. Free T4 values in women taking oral contraceptives are normal. Depressed results were often observed in acute nonthyroidal illness and continuing pregnancy. These results were directly comparable with those of another commercial direct radiolabeled-T4 analog kit for free T4

  16. Adrenal status assessed by direct radioimmunoassay of cortisol in whole saliva or parotid saliva

    International Nuclear Information System (INIS)

    Walker, R.F.; Riad-Fahmy, D.; Read, G.F.

    1978-01-01

    We describe a direct radioimmunoassay for cortisol in 10-μl volumes of parotid saliva or whole saliva. Binding proteins are absent from these fluids, as demonstrated by the excellent correlation between results for samples assayed directly and by a comparison procedure involving extraction with 1,2-dichloroethane. The direct assay is specific, precise, and had a lower limit of sensitivity of 4 pg per assay tube. Comparison of cortisol concentrations in plasma, parotid saliva, and whole saliva in persons undergoing investigations for assessing adrenal function, including stimulation with cosyntropin (Synachthen) and suppression with dexamethasone, indicated that changes in plasma cortisol concentration were accurately and immediately reflected in saliva from either the parotid-gland or whole saliva. A marked circadian rhythm has also been demonstrated for cortisol in parotid-gland saliva and whole saliva. We had to modify the 1,2-dichloroethane extraction procedure for accurate determination of cortisol in parotid saliva and whole saliva of patients undergoing treatment with metyrapone

  17. Solid-phase extraction with the metal-organic framework MIL-101(Cr) combined with direct analysis in real time mass spectrometry for the fast analysis of triazine herbicides.

    Science.gov (United States)

    Li, Xianjiang; Xing, Jiawei; Chang, Cuilan; Wang, Xin; Bai, Yu; Yan, Xiuping; Liu, Huwei

    2014-06-01

    MIL-101(Cr) is an excellent metal-organic framework with high surface area and nanoscale cavities, making it promising in solid-phase extraction. Herein, we used MIL-101(Cr) as a solid-phase extraction packing material combined with fast detection of direct analysis in real time mass spectrometry (DART-MS) for the analysis of triazine herbicides. After systematic optimization of the operation parameters, including the gas temperature of DART, the moving speed of the 1D platform, solvent for desorption, amount of MIL-101(Cr) extraction time, eluent volume and salt concentration, this method can realize the simultaneous detection of five kinds of triazine herbicides. The limits of detection were 0.1∼0.2 ng/mL and the linear ranges covered more than two orders of magnitude with the quantitation limits of 0.5∼1 ng/mL. Moreover, the developed method has been applied for the analysis of lake water samples and the recoveries for spiked analytes were in the range of 85∼110%. These results showed that solid-phase extraction with metal-organic frameworks is an efficient sample preparation approach for DART-MS analysis and could find more applications in environmental analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. A radioimmunoassay for chicken avidin

    International Nuclear Information System (INIS)

    Kulomaa, M.S.; Elo, H.A.; Tuohimaa, P.J.

    1978-01-01

    A double-antibody solid-phase radioimmunoassay for chicken avidin is reported. Avidin was labelled with 125 I by the chloramine-T method. The bound and free avidin were separated with a second antibody bound to a solid matrix. In the logit-log scale the standard curve was linear from 1-2 to 100-200ng of avidin/ml. Cross-reaction of ovalbumin was less than 0.015%. Saturation of biotin-binding sites of avidin with an excess of biotin decreased radioimmunoassay values by about 15%. Recovery studies indicated that avidin can be assayed from all chicken tissues studied with radioimmunoassay, whereas the [ 14 C]biotin/bentonite method gave poor recoveries for avidin in the liver and kidney. Radioimmunoassay and the [ 14 C]biotin/bentonite method gave similar concentrations for oviduct avidin. (author)

  19. Direct radioimmunoassay of 17. beta. -estradiol in ether extracts of bovine

    Energy Technology Data Exchange (ETDEWEB)

    Medina, M.B.

    Anabolic estrogens such as 17..beta..-estradiol or 17..beta..-estradiol benzoate are used to promote growth and increase feed efficiency in food-producing cattle. This paper describes a technique to produce a more specific antibody to 17..beta..-estradiol by intradermal immunization using microquantities of 6-(carboxymethyl)-17..beta..-estradiol oxime bovine serum albumin and the development of a radioimmunoassay (RIA) procedure to measure directly the amounts of 17..beta..-estradiol in ether extracts of bovine serum without using cleanup procedures. Results demonstrated that a specific and sensitive antibody was produced, and a titer of 1:10,000 was used in the RIA procedure. Antibody cross-reactivity with ..beta..-estradiol metabolites and other anabolic estrogens was negligible. The untreated bovine sera showed 0-24 pg of apparent 17..beta..-estradiol/mL, while 0-31 pg/mL total estrogens had been reported in the literature. This assay can measure 5-100 pg in 20-250..mu..L/sample. This method can be used before or immediately after slaughter to monitor the residual amounts of estradiol used in the treatment of cattle.

  20. Direct radioimmunoassay of 17β-estradiol in ether extracts of bovine

    International Nuclear Information System (INIS)

    Medina, M.B.

    1986-01-01

    Anabolic estrogens such as 17β-estradiol or 17β-estradiol benzoate are used to promote growth and increase feed efficiency in food-producing cattle. This paper describes a technique to produce a more specific antibody to 17β-estradiol by intradermal immunization using microquantities of 6-(carboxymethyl)-17β-estradiol oxime bovine serum albumin and the development of a radioimmunoassay (RIA) procedure to measure directly the amounts of 17β-estradiol in ether extracts of bovine serum without using cleanup procedures. Results demonstrated that a specific and sensitive antibody was produced, and a titer of 1:10,000 was used in the RIA procedure. Antibody cross-reactivity with β-estradiol metabolites and other anabolic estrogens was negligible. The untreated bovine sera showed 0-24 pg of apparent 17β-estradiol/mL, while 0-31 pg/mL total estrogens had been reported in the literature. This assay can measure 5-100 pg in 20-250μL/sample. This method can be used before or immediately after slaughter to monitor the residual amounts of estradiol used in the treatment of cattle

  1. Validation of a direct radioimmunoassay of melatonin in the blue fox

    International Nuclear Information System (INIS)

    Forsberg, M.; Madej, A.

    1987-01-01

    A direct radioimmunoassay procedure for the determination of melatonin in the blood of blue fox has been validated and applied. The assay required 50 μl of sample and standard, 100 μl of antiserum and 100 μl of ( 3 H)melatonin. After overnight incubation at 4 deg. C the antibody bound melatonin was separated from the free hormone with dextran-coated charcoal. Following centrifugation the antibody bound ( 3 H)melatonin was determined in a beta scintillation counter. The antiserum bound 30-35 % of the ( 3 H)melatonin at a final dilution of 1:36000. The non specific binding represented less than 5 % of the total radioactivity in all assays. The lowest detectable amount of melatonin was 2.6 fmol/tube, corresponding to 52.5 pmol/l. The inter-assay coefficient of variation at 178 and 510 pmol/l was 15.6 and 8.8 %, respectively. The precision profile, calculated from a 10-replicate standard curve, showed that the coefficient of variation decreased from 43 % at 84 pmol/l to 15 % at 336 pmol/l, and remainded at or below 10 % for concentrations exceeding 670 pmol/l. Plasma was collected from 2 male blue foxes at about hourly intervals during a 24 h period in September and assayed for melatonin. Maximum (421 pmol/l) and minimum (97 pmol/l) concentrations of the hormone were inversely related to light intensity. (author)

  2. Specificity of direct radioimmunoassays of unconjugated estrone and estradiol-17β in plasma

    International Nuclear Information System (INIS)

    Grenier, J.; Strauss, N.; Scholler, R.

    1977-01-01

    Procedures for radioimmunoassay of estrone and estradiol-17β in plasma, which do not include a chromatographic step or even plasma extractions are now described in the literature and are recommended in most commercially available kits. Besides leading often to a systematic overestimation of estrogen concentrations, such techniques are liable to give results which are volume-dependent. Since this defect might be due to the type of antiserum used or the mode of separation of free and antibodybound steroid, the influence of plasma volume was studied, either with a modification of Castanier and Scholler method - i.e. suppression of Sephadex LH-20 chromatography -, using antisera of different types, or with estrogen kits. The separation step was a toluene extraction in the modified method, and dextran-coated charcoal or polyethylene glycol in procedures of commercial kits. The volume effect was always found, with varying degrees, according to the plasma sample. It was most marked in plasmas of hyperlipidemic patients. The addition of fatty acids, at an upper physiological dose, led to a modification of the standard curve, with over-estimation at low levels and under-estimation at high levels, resulting in calculated estrogen concentrations depending on volume. The use of highly specific antiserum as determined by cross-reaction studies with authentic steroids does not necessarily imply the possibility of performing direct assays which ought to pass the test of plasma volume effect before being accepted. (orig.) [de

  3. Direct radioimmunoassay of serum progesterone using heterologous bridge tracer and antibody

    International Nuclear Information System (INIS)

    Kothari, K.; Pillai, M.R.A.

    1998-01-01

    The standardisation of a direct radioimmunoassay for progesterone using an 125 I labeled progesterone prepared by iodinating the tyrosine methyl ester (TME) conjugated to a progesterone hemiphthalate derivative and an antibody prepared using a progesterone linked to bovine serum albumin through 11α hemisuccinate derivative is described. The hemiphthalate derivative of progesterone was prepared by reacting 11α-hydroxy progesterone with phthalic anhydride which was then conjugated to TME by using isobutyl chloroformate. The conjugate was iodinated with 125 I using chloramine-T as oxidising agent and purified by thin layer chromatography. Radiochemical purity of the tracer was >95% in all batches. The tracer gave 70-75% binding with excess antibody. Assays were optimised with 8-anilino-1-naphthalene sulphonic acid (ANS) and sodium salicylate as blocking agents to release the progesterone from binding proteins. The assays optimised with sodium salicylate as blocking agent has a sensitivity of 0.25 ng/ml and a working range of 0.25-50 ng/ml, whereas the assay with ANS has a sensitivity of 0.75 ng/ml and a working range of 0.75-100 ng/ml. Serum samples were analysed and compared with the values obtained with a homologous bridge assay. (author)

  4. Serum and urinary oestrone sulphate in pregnancy and delivery measured by a direct radioimmunoassay

    International Nuclear Information System (INIS)

    Honjo, Hideo; Kitawaki, Jo; Itoh, Masafumi; Yasuda, Jinsuke; Yamamoto, Takara; Yamamoto, Takao; Okada, Hiroji; Ohkubo, Tadashi; Nambara, Toshio

    1986-01-01

    Serum and urinary levels of oestrone sulphate in pregnancy and delivery were measured by a direct radioimmunoassay without hydrolysis. the serum and urinary oestrone sulphate increased as pregnancy progressed. the mean level of serum oestrone sulphate increased to the highest peak of 494 pmol/ml at the 35th gestational week and then decreased. The mean level of urinary oestrone sulphate increased to the highest peak of 1.28 μmol/l at the 34th gestational week and the decreased. At vaginal deliveries, the mean level of maternal peripheral serum oestrone sulphate increased hourly at as high a level as 979 pmol/ml. The mean serum level of oestrone sulphate was 204 pmol/ml in the umbilical artery and 145 pmol/ml in the umbilical vein. At Caesarean section, on the other hand, the maternal peripheral serum level of oestrone sulphate averaged 362 pmol/ml. The mean serum levels of oestrone sulphate wre 90.7 pmol/ml and 171 pmol/ml in the umbilical artery and umbilical vein, respectively. These results suggest a maternal origin of oestrone sulphate in pregnancy, with fluctuations in the levels being of interest in relation to labour pain. (author)

  5. Indirect solid-phase immunosorbent assay for detection of arenavirus antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A [Institute of Poliomyelitis anU Viral Encephalities of the U.S.S.R. Academy of Medical Sciences, Moscow

    1984-05-01

    Indirect enzyme-linked immunosorbent assay (ELISA) and solid phase radioimmunoassay (SPRIA) using either enti-human or anti-mouse IgG labelled with horseradish peroxidase and /sup 125/I, respectively, were developed for the detection of Junin, Machupo, Tacaribe, Amapari, Tamiami, Lassa and LCM arenaviruses. Both methods allow high sensitivity detection of arenavirus antigens and antibodies.

  6. Solid-phase peptide synthesis

    DEFF Research Database (Denmark)

    Jensen, Knud Jørgen

    2013-01-01

    This chapter provides an introduction to and overview of peptide chemistry with a focus on solid-phase peptide synthesis. The background, the most common reagents, and some mechanisms are presented. This chapter also points to the different chapters and puts them into perspective.......This chapter provides an introduction to and overview of peptide chemistry with a focus on solid-phase peptide synthesis. The background, the most common reagents, and some mechanisms are presented. This chapter also points to the different chapters and puts them into perspective....

  7. Direct-immersion solid-phase microextraction coupled to fast gas chromatography mass spectrometry as a purification step for polycyclic aromatic hydrocarbons determination in olive oil.

    Science.gov (United States)

    Purcaro, Giorgia; Picardo, Massimo; Barp, Laura; Moret, Sabrina; Conte, Lanfranco S

    2013-09-13

    The aim of the present work was to optimize a preparation step for polycyclic aromatic hydrocarbons in a fatty extract. Solid-phase microextraction is an easy preparation technique, which allows to minimize solvent consumption and reduce sample manipulation. A Carbopack Z/polydimethylsiloxane fiber, particularly suitable for extraction of planar compounds, was employed to extract polycyclic aromatic hydrocarbons from a hexane solution obtained after a previous extraction with acetonitrile from oil, followed by a liquid-liquid partition between acetonitrile and hexane. The proposed method was a rapid and sensitive solution to reduce the interference of triglycerides saving the column life and avoiding frequent cleaning of the mass spectrometer ion source. Despite the non-quantitative extraction of polycyclic aromatic hydrocarbons from oil using acetonitrile, the signal-to-noise ratio was significantly improved obtaining a limit of detection largely below the performance criteria required by the European Union legislation. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Multiple solid-phase microextraction

    NARCIS (Netherlands)

    Koster, EHM; de Jong, GJ

    2000-01-01

    Theoretical aspects of multiple solid-phase microextraction are described and the principle is illustrated with the extraction of lidocaine from aqueous solutions. With multiple extraction under non-equilibrium conditions considerably less time is required in order to obtain an extraction yield that

  9. Direct Zinc Determination in Brazilian Sugar Cane Spirit by Solid-Phase Extraction Using Moringa oleifera Husks in a Flow System with Detection by FAAS.

    Science.gov (United States)

    Alves, Vanessa N; Borges, Simone S O; Coelho, Nivia M M

    2011-01-01

    This paper reports a method for the determination of zinc in Brazilian sugar cane spirit, (cachaça in Portuguese), using solid-phase extraction with a flow injection analysis system and detection by FAAS. The sorbent material used was activated carbon obtained from Moringa oleifera husks. Flow and chemical variables of the proposed system were optimized through multivariate designs. The factors selected were sorbent mass, sample pH, sample flow rate, and eluent concentration. The optimum extraction conditions were obtained using a sample pH of 4.0, a sample flow rate of 6.0 mL min(-1), 30.0 mg of sorbent mass, and 1.0 mol L(-1) HNO(3) as the eluent at a flow rate of 4.0 mL min(-1). The limit of detection for zinc was 1.9 μg L(-1), and the precision was below 0.82% (20.0 μg L(-1), n = 7). The analytical curve was linear from 2 to 50 μg L(-1), with a correlation coefficient of 0.9996. The method developed was successfully applied to spiked Brazilian sugar cane spirit, and accuracy was assessed through recovery tests, with results ranging from 83% to 100%.

  10. Direct Zinc Determination in Brazilian Sugar Cane Spirit by Solid-Phase Extraction Using Moringa oleifera Husks in a Flow System with Detection by FAAS

    Directory of Open Access Journals (Sweden)

    Vanessa N. Alves

    2011-01-01

    Full Text Available This paper reports a method for the determination of zinc in Brazilian sugar cane spirit, (cachaça in Portuguese, using solid-phase extraction with a flow injection analysis system and detection by FAAS. The sorbent material used was activated carbon obtained from Moringa oleifera husks. Flow and chemical variables of the proposed system were optimized through multivariate designs. The factors selected were sorbent mass, sample pH, sample flow rate, and eluent concentration. The optimum extraction conditions were obtained using a sample pH of 4.0, a sample flow rate of 6.0 mL min-1, 30.0 mg of sorbent mass, and 1.0 mol L-1 HNO3 as the eluent at a flow rate of 4.0 mL min-1. The limit of detection for zinc was 1.9 μg L-1, and the precision was below 0.82% (20.0 μg L-1, n=7. The analytical curve was linear from 2 to 50 μg L-1, with a correlation coefficient of 0.9996. The method developed was successfully applied to spiked Brazilian sugar cane spirit, and accuracy was assessed through recovery tests, with results ranging from 83% to 100%.

  11. Direct preparation of a graphene oxide modified monolith in a glass syringe as a solid-phase extraction cartridge for the extraction of quaternary ammonium alkaloids from Chinese patent medicine.

    Science.gov (United States)

    Liang, Xiaojing; Wang, Licheng; Wang, Shuai; Li, Yijing; Guo, Yong

    2017-11-01

    Packed cartridges have been widely used in solid-phase extraction. However, there are still some drawbacks, such as they are blocked easily and the method is time-consuming. In view of the advantages of monoliths, a monolithic extraction material has been directly synthesized in a glass syringe without any gap between the monolith and syringe inner wall. The monolithic syringe was modified with graphene oxide by loading graphene oxide dispersion onto it. The content of graphene oxide and the surface topography of the monolith have been evaluated by elemental analysis and scanning electron microscopy, respectively, which confirmed the successful modification. This prepared graphene oxide-modified monolithic syringe was directly used as a traditional solid-phase extraction cartridge. As expected, it shows good permeability and excellent capability for the extraction of quaternary ammonium alkaloids. The sample loading velocity (1-6 mL/min) does not affect the recovery. Under the optimal conditions, good linearities (R = 0.9992-0.9998) were obtained for five quaternary ammonium alkaloids, and the limits of detection and quantification were 0.5-1 and 1-2 μg/L, respectively. The proposed method was successfully applied for the analysis of quaternary ammonium alkaloids in Chinese patent medicine. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Progesterone radioimmunoassay

    International Nuclear Information System (INIS)

    Allen, R.M.; Redshaw, M.R.

    1981-01-01

    This patent claims a radioimmunoassay for progesterone, which comprises contacting, in an acidic medium a sample of liquid with a predetermined amount of antibodies raised against a progesterone-protein complex, the protein being attached to the 11-position of progesterone by means of a bridging group and with a predetermined amount of a progesterone derivative having an iodinatable group attached to its 3-position by means of a bridging group, the iodinatable group being iodinated with one or more atom(s) of a radioisotope of iodine, separating the steroid bound in the resulting antibody-antigen complex from the free steroid and measuring the radioactivity of the free steroid component or of the antibody-antigen complex. Sufficient sensitivity has been achieved to enable a progesterone assay to be carried out directly on a sample of biological fluid, such as serum, plasma, urine or milk. (U.K.)

  13. Fast and robust direct immersion solid phase microextraction coupled with gas chromatography-time-of-flight mass spectrometry method employing a matrix compatible fiber for determination of triazole fungicides in fruits.

    Science.gov (United States)

    Silva, Érica A Souza; Lopez-Avila, Viorica; Pawliszyn, Janusz

    2013-10-25

    A fast and robust method was developed for the determination of ten triazole fungicides in fruit samples using direct immersion solid-phase microextraction coupled to gas chromatography with time-of-flight mass spectrometry detection (DI-SPME-GC-ToFMS). In this work, a newly developed concept of solid-phase microextraction (SPME) sorbent, which allows for direct immersion extraction in complex food matrices, has been applied in the analysis of 10 triazole fungicides in grapes and strawberries pulps. Potential factors affecting the extraction efficiency were investigated and optimized, including extraction temperature, sample pH, and ionic strength, agitation speed, extraction and desorption times. Under optimized conditions, the method was linear for over 4 orders of magnitude in concentration, with linear regression coefficients (R(2)) greater than 0.99 for all test compounds in both matrices. Method reproducibility, as determined by analysis of spiked grapes and strawberries, was better than ±20%. The limits of quantitation objective (LOQs) ranged from 0.25 to 5 ng g(-1) for both matrices, well below the maximum residues levels allowed for those compounds in both matrices. The method was successfully applied in the analysis of commercial samples of grapes and strawberries. Finally, the new SPME method was compared to a modified version of t QuEChERS AOAC method: the limits of quantitation reached by SPME were at least one order of magnitude lower than those achieved by the QuEChERS method, whereas precision and accuracy were comparable for both methods. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Direct radioimmunoassay for the detection of barbiturates in blood and urine

    International Nuclear Information System (INIS)

    Mason, P.A.; Law, B.; Pocock, K.; Moffat, A.C.

    1982-01-01

    A radioimmunoassay has been developed for the detection of barbiturates in blood and urine without any pre-treatment of the sample. It is based on a radioiodinated derivative of 4-hydroxyphenobarbitone which allows use of relatively simple gamma-counting procedures. The assay can detect therapeutic levels of barbiturates in very small amounts (50 μl) of blood and urine samples. It is cheap, rapid, simple to perform and is broadly specific for the barbiturate class of drugs to the exclusion of related drugs. The assay is, therefore, very well suited to the task of screening large numbers of samples for the presence of barbiturates. (author)

  15. Design of indirect solid-phase immunosorbent methods for detecting arenavirus antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A

    1984-05-01

    Specifications have been elaborated for formulating indirect solid-phase enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (SPRIA) methods that employ anti-human and anti-mice G class immunoglobulin (IgG), conjugated with horseradish peroxidase and /sup 125/I for detecting the arenaviruses Junin, Machupo, Tacaribe, Amalpari, Tamiami, Lassa, and LCM (lymphocytic choriomeningitis). These methods make it possible to identify with a high degree of sensitivity arenavirus antigens and antibodies in various kinds of material.

  16. Determination of organotin compounds in waters by headspace solid phase microextraction gas chromatography triple quadrupole tandem mass spectrometry under the European Water Framework Directive.

    Science.gov (United States)

    Moscoso-Pérez, C; Fernández-González, V; Moreda-Piñeiro, J; López-Mahía, P; Muniategui-Lorenzo, S; Prada-Rodríguez, D

    2015-03-13

    The European Union Water Framework Directive (2013/39/EU) sets very restrictive environmental quality standards for 45 priority substances and other pollutants, including organotin compounds (OTCs). Therefore, it is necessary to develop analytical methods in compliance with the environmental quality standard (EQSs) proposed to protect the aquatic environment and humans. The proposed method (HS-SPME-GC-QqQ-MS/MS) allows the determination of OTCs, i.e. monobutyltin (MBT), dibutyltin (DBT) and TBT in water in the range of few ng L(-1). The method is nearly full automated, sensitive and simple; it involves less reagents, reduces waste, and is less-time consuming than traditional methods for OTCs. As such, the procedure connects with the principles of green analytical chemistry. Additionally, good precision (RSD<20%), a very low method quantification limit (MQL) (0.76 ng L(-1) for TBT by using only 10 mL of sample) and excellent linearity (range MQL-20 ng L(-1)) are achieved. Under these conditions, the very restrictive limits for the environmental quality standards (EQS) fixed by the 2013/39/EU Directive are achieved. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Methodical evaluation and improvement of matrix compatible PDMS-overcoated coating for direct immersion solid phase microextraction gas chromatography (DI-SPME-GC)-based applications.

    Science.gov (United States)

    Souza-Silva, Érica A; Gionfriddo, Emanuela; Shirey, Robert; Sidisky, Len; Pawliszyn, Janusz

    2016-05-12

    The main quest for the implementation of direct SPME to complex matrices has been the development of matrix compatible coatings that provide sufficient sensitivity towards the target analytes. In this context, we present here a thorough evaluation of PDMS-overcoated fibers suitable for simultaneous extraction of different polarities analytes, while maintaining adequate matrix compatibility. For this, eleven analytes were selected, from various application classes (pesticides, industrial chemicals and pharmaceuticals) and with a wide range of log P values (ranging from 1.43 to 6). The model matrix chosen was commercial Concord grape juice, which is rich in pigments such as anthocyanins, and contains approximately 20% of sugar (w/w). Two types of PDMS, as well as other intrinsic factors associated with the PDMS-overcoated fiber fabrication are studied. The evaluation showed that the PDMS-overcoated fibers considerably slowed down the coating fouling process during direct immersion in complex matrices of high sugar content. Longevity differences could be seen between the two types of PDMS tested, with a proprietary Sylgard(®) giving superior performance because of lesser amount of reactive groups and enhanced hydrophobicity. Conversely, the thickness of the outer layer did not seem to have a significant effect on the fiber lifetime. We also demonstrate that the uniformity of the overcoated PDMS layer is paramount to the achievement of reliable data and extended fiber lifetime. Employing the optimum overcoated fiber, limits of detection (LOD) in the range of 0.2-1.3 ng/g could be achieved. Additional improvement is attainable by introducing washing of the coatings after desorption, so that any carbon build-up (fouling) left on the coating surface after thermal desorption can be removed. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. A simple and rapid characterization of influenza virus isolates by monoclonal antibodies in radioimmunoassay

    International Nuclear Information System (INIS)

    Kostolansky, F.; Styk, B.; Russ, G.

    1986-01-01

    Radioimmunoassay is described with infectious allantoic fluid directly bound to solid phase, suitable for the detection and further characterization of influenza virus isolates. This simple and rapid method was applied for the description of isolates obtained from different regions of Czechoslovakia during the influenza epidemic in 1983. The results confirmed that all 13 examined isolates represented influenza A viruses possessing H3 subtype haemagglutinin very similar to haemagglutinin of influenza viruses A/Bangkok/1/79 (H3N2), A/Belgium/2/81 (H3N2) and A/Philippines/2/82 (H3N2). (author)

  19. Ultrafast Screening and Quantitation of Pesticides in Food and Environmental Matrices by Solid-Phase Microextraction-Transmission Mode (SPME-TM) and Direct Analysis in Real Time (DART).

    Science.gov (United States)

    Gómez-Ríos, Germán Augusto; Gionfriddo, Emanuela; Poole, Justen; Pawliszyn, Janusz

    2017-07-05

    The direct interface of microextraction technologies to mass spectrometry (MS) has unquestionably revolutionized the speed and efficacy at which complex matrices are analyzed. Solid Phase Micro Extraction-Transmission Mode (SPME-TM) is a technology conceived as an effective synergy between sample preparation and ambient ionization. Succinctly, the device consists of a mesh coated with polymeric particles that extracts analytes of interest present in a given sample matrix. This coated mesh acts as a transmission-mode substrate for Direct Analysis in Real Time (DART), allowing for rapid and efficient thermal desorption/ionization of analytes previously concentrated on the coating, and dramatically lowering the limits of detection attained by sole DART analysis. In this study, we present SPME-TM as a novel tool for the ultrafast enrichment of pesticides present in food and environmental matrices and their quantitative determination by MS via DART ionization. Limits of quantitation in the subnanogram per milliliter range can be attained, while total analysis time does not exceed 2 min per sample. In addition to target information obtained via tandem MS, retrospective studies of the same sample via high-resolution mass spectrometry (HRMS) were accomplished by thermally desorbing a different segment of the microextraction device.

  20. Steroid radioimmunoassays

    International Nuclear Information System (INIS)

    Shinde, Y.; Hacker, R.R.; Ntunde, B.; Smith, V.G.

    1981-01-01

    An estrogen radioimmunoassay was used to study the problem of blanks in steroid assays. Negligible binding (1.5 percent) in the non-antibody tubes prevailed throughout the study. The assay was validated using accepted procedures. Both water and solvent blanks had estrogen concentrations of 7-9 pg/tube. However, neither water nor solvent blanks showed a dose-related response, indicating that they were 'real' blanks. Exogenous estradiol, when added to water and solvent in quantities less than the estimated blank, was not quantitatively recovered. However, exogenous estradiol added to the water solvent in quantities greater than the blank estimate was quantitatively recovered. The sensitivity of the reference standard curve was 6-10 pg/tube, approximately the same as the blank estimate. These results indicated that the estimates of water and solvent blanks were measures of the assay sensitivity. In such circumstances, it is suggested that blank estimates should not be subtracted from sample values. If the blank estimates are high, attention should be directed towards improving the sensitivity of the assay

  1. Cold vapor-solid phase microextraction using amalgamation in different Pd-based substrates combined with direct thermal desorption in a modified absorption cell for the determination of Hg by atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Romero, Vanesa; Costas-Mora, Isabel; Lavilla, Isela; Bendicho, Carlos

    2011-01-01

    In this work, different Pd-based substrates (i.e. Pd wire, Pd-coated stainless steel wire and Pd-coated SiO 2 ) are tried for microextraction of Hg prior to its release into a modified quartz T-cell so as to develop a cost-effective, sensitive and easy-to-handle coupling between solid-phase microextraction (SPME) and atomic absorption spectrometry. The new design allows a direct sample injection from the SPME device into a quartz T-cell thus avoiding analyte dilution. Mercury amalgamation onto a Pd wire provided the best performance in respect to sensitivity and fiber lifetime, but Pd wires could not be implemented in the SPME device due to their poor mechanical characteristics. On the contrary, Pd-coated SiO 2 fibers could be easily adapted to the typical sampling device used for SPME. Narrow time-dependent absorption signal profiles that could be integrated within 25 s were obtained. The detection limit was 90 pg mL -1 of Hg, and the repeatability expressed as relative standard deviation was 4.3%.

  2. Quantification of 2,5-dimethyl-4-hydroxy-3(2H)-furanone using solid-phase extraction and direct microvial insert thermal desorption gas chromatography-mass spectrometry.

    Science.gov (United States)

    Du, Xiaofen; Qian, Michael

    2008-10-24

    A GC-MS method for the determination of furaneol in fruit juice was developed using Lichrolut-EN solid-phase extraction (SPE) coupled to microvial insert thermal desorption. Lichrolut-EN can effectively extract furaneol from juice, and had much less retention for pigments and other non-volatiles than HLB and C18 columns. The furaneol can be completely eluted out from the Lichrolut-EN SPE column with 1mL of methanol, which can be directly analyzed on GC-MS using an automated large volume microvial insert thermal desorption technique without further purification and concentration. The method is sensitive, has good recovery (98%) and reproducibility (CVfuraneol in some commonly grown strawberry, raspberry, and blackberry cultivars in Pacific Northwest of the United States was determined. Strawberries had the highest concentration of furaneol with 'Totem' and 'Pinnacle' cultivars over 13mgkg(-1) fruit. 'Marion' blackberry had 5 times more furaneol than 'Black Diamond', and 16 times more than 'Thornless Evergreen' blackberry. Raspberries had furaneol concentration ranged from 0.8 to 1.1mgkg(-1) fruit.

  3. Direct determination of free thyroxine in two simultaneous radioimmunoassays with different test principles

    International Nuclear Information System (INIS)

    Lohkamp, F.; Schmidt, M.

    1982-01-01

    Serum FT 4 was measured simultaneously by the commercial FT 4 kits of Amersham-Buchler and Corning Medical in 4 groups with defined thyroid function as follows: 57 euthroid subjects with and without goitre, 27 patients on T 4 supplementation. 12 subjects on oral contraceptives and 26 subclinically hyperthyroid patients. All patients underwent physical examination, thyroid scintigraphy and additional in-vitro tests (total thyroxine T 4 , total triiodothyronine T 3 and TRH/TSH assay). Both assays generally correlated well with the definded thyroid functional status except for the patients on oral contraceptives. Contrary to the FT 4 -test (Amersham-Buchler) in this group the FT 4 -test (Corning Medical) produced a significantly increased mean for FT 4 as compared to the euthyroid group thus indicating a probably insufficient compensation for high but not necessarily abnormal levels of TBG concentration. Using the FT 4 -assay (Amersham-Buchler) the normal range of FT 4 values of euthyroid subjects from the area of Bamberg with marked iodine deficiency agrees well with recently published results of a multicentre trial thus confirming the assumption of serum FT 4 not being strongly dependent on iodine intake. The results of the FT 4 -test (Corning) showed a wider scatter of normal ranges of FT 4 values for all groups and concomitantly reduced discrimination compared to the corresponding simultaneously obtained FT 4 -test (Amersham-Buchler) results. Though cost and time saving, the commercial radioimmunoassays will require further critical evaluation of normal range validity on larger populations of defined abnormalities will require further critical evaluation of normal range validity on larger populations of defined abnormalities of thyroid function to elucidate inherent deficiencies of the new FT 4 methods and of their diagnostic efficiency. (orig./MG) [de

  4. In-tube solid-phase microextraction based on NH2-MIL-53(Al)-polymer monolithic column for online coupling with high-performance liquid chromatography for directly sensitive analysis of estrogens in human urine.

    Science.gov (United States)

    Luo, Xialin; Li, Gongke; Hu, Yufei

    2017-04-01

    In this work, a novel NH 2 -MIL-53(Al) incorporated poly(styrene-divinylbenzene-methacrylic acid) (poly(St-DVB-MAA)) monolith was prepared via chemical fabrication. Moreover, it has been efficiently applied to the in-tube solid-phase microextraction (SPME) for online coupling with high-performance liquid chromatography (HPLC) to the direct determination of five estrogens in human urine samples. The NH 2 -MIL-53(Al)-polymer monolith was suitable for in-tube SPME owing to its good permeability, high extraction efficiency, chemical stability, good reproducibility and long lifetime. The extraction conditions including extraction solvent, pH of sample solution, flow rate of extraction and desorption, and desorption volume were investigated. Under the optimum conditions, the enrichment factors were 180-304 and saturated amounts of extraction were 2326-21393 pmol for estriol, 17β-estradiol, estrone, ethinyl estradiol and progesterone, respectively. The adsorption mechanism was also explored which contributed to its strong extraction to target compounds. The proposed method had low limit of detection (2.0-40ng/L) and good linearity (with R 2 between 0.9908 and 0.9978). Four endogenous estrogens were detected in urine samples and the recoveries of all five analytes were ranged from 75.1-120% with relative standard deviations (RSDs) less than 8.7%. The results showed that the proposed online SPME-HPLC method based on NH 2 -MIL-53(Al)-polymer monolithic column was highly sensitive for directly monitoring trace amount of estrogens in human urine sample. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. Solid Phase Extraction and Spectrophotometric Determination of ...

    African Journals Online (AJOL)

    NJD

    2005-04-15

    Apr 15, 2005 ... to the economy and has significant industrial applications. The development of a ... Waters Solid Phase Extraction (SPE) device (the device can carry out twenty ... HPLC grade dimethyl formamide (DMF) (Fisher. Corporation ...

  6. solid phase extraction method for selective determination

    African Journals Online (AJOL)

    FATOKI

    determination of phthalate ester plasticizers in rivers and marine water samples. Of the ... samples that receive effluent from industries that use phthalate esters. ... Keywords Phthalates, Plasticizers, Solid Phase Gas Chromatography.

  7. Comparison of direct, headspace and headspace cold fiber modes in solid phase microextraction of polycyclic aromatic hydrocarbons by a new coating based on poly(3,4-ethylenedioxythiophene)/graphene oxide composite.

    Science.gov (United States)

    Banitaba, Mohammad Hossein; Hosseiny Davarani, Saied Saeed; Kazemi Movahed, Siyavash

    2014-01-17

    A novel nanocomposite coating made of poly(3,4-ethylenedioxythiophene) (PEDOT) and graphene oxide was electrochemically prepared on gold wire. The prepared fiber was applied to the solid-phase microextraction (SPME) and gas chromatographic analysis of six polycyclic aromatic hydrocarbons (PAHs). Three modes of extraction i.e. direct immersion (DI), headspace (HS) and headspace cold fiber (HS-CF) in SPME were investigated. The results were compared under optimized conditions of each mode, considering the effects of the three most important parameters which are extraction temperature, extraction time and ionic strength. The comparison showed that HS-CF-SPME results in the best outcome for the extraction of PAHs from water samples. Under the optimized conditions of this mode, the calibration curves were linear within the range of 0.4-600μgL(-1) and the detection limits were between 0.05 and 0.13μgL(-1). The intra-day and inter-day relative standard deviations obtained at 10μgL(-1) (n=5), using a single fiber, were 4.1-6.8% and 4.8-8.4%, respectively. The fiber-to-fiber repeatabilities (n=4), expressed as the relative standard deviations (RSD%), were between 6.5% and 10.7% at a 10μgL(-1) concentration level. The method was successfully applied to the analysis of PAHs in seawater samples showing recoveries from 85% to 107%. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Single-Use Poly(etheretherketone) Solid-Phase Microextraction-Transmission Mode Devices for Rapid Screening and Quantitation of Drugs of Abuse in Oral Fluid and Urine via Direct Analysis in Real-Time Tandem Mass Spectrometry.

    Science.gov (United States)

    Vasiljevic, Tijana; Gómez-Ríos, Germán Augusto; Pawliszyn, Janusz

    2018-01-02

    The analysis of oral fluid (OF) and urine samples to detect drug consumption has garnered considerable attention as alternative biomatrices. Efficient implementation of microextraction and ambient ionization technologies for rapid detection of target compounds in such biomatrices creates a need for biocompatible devices which can be implemented for in vivo sampling and easily interfaced with mass spectrometry (MS) analyzers. This study introduces a novel solid-phase microextraction-transmission mode (SPME-TM) device made of poly(etheretherketone) (PEEK) mesh that can rapidly detect prohibited substances in biofluids via direct analysis in real-time tandem MS (DART-MS/MS). PEEK mesh was selected due to its biocompatibility, excellent resistance to various organic solvents, and its ability to withstand relatively high temperatures (≤350 °C). The meshes were coated with hydrophilic-lipophilic-balance particle-poly(acrylonitrile) (HLB-PAN) slurry. The robustness of the coated meshes was tested by performing rapid vortex agitation (≥3200 rpm) in LC/MS-grade solvents and by exposing them to the DART source jet stream at typical operational temperatures (∼250-350 °C). PEEK SPME-TM devices proved to be robust and were therefore used to perform ex vivo analysis of drugs of abuse spiked in urine and OF samples. Excellent results were obtained for all analytes under study; furthermore, the tests yielded satisfactory limits of quantitation (median, ∼0.5 ng mL -1 ), linearity (≥0.99), and accuracy (80-120%) over the evaluated range (0.5-200 ng mL -1 ). This research highlights plastic SPME-TM's potential usefulness as a method for rapidly screening for prohibited substances in on-site/in vivo scenarios, such as roadside or workplace drug testing, antidoping controls, and pain management programs.

  9. Sensitive chain specific radioimmunoassay for human immunoglobulins using monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Sikora, K; Alderson, T St.J.; Ellis, J [Ludwig Institute for Cancer Research, Cambridge (UK)

    1983-02-25

    A sensitive radioimmunoassay is described for human immunoglobulins. This solid-phase assay uses commercially available monoclonal antibodies and is specific for different Ig chain types. Levels of less than 20 ng/ml Ig are detectable. The assay is suitable for the analysis of human hybridoma supernatants.

  10. Radioimmunoassay of estriol-16-glucuronide using tritiated and radioiodinated radioligands: direct radioimmunoassay of urinary estriol-16-glucuronide during the menstrual cycle

    International Nuclear Information System (INIS)

    Stanczyk, F.Z.; Miyakawa, I.; Soares, J.R.; Goebelsmann, U.

    1979-01-01

    Estriol-16-glucuronide-[ 125 I]-iodohistamine (E 3 -16G-[ 125 ]) was prepared and utilized in a radioimmunoassay (RIA) in conjunction with anti-estriol-16-glucuronide-bovine serum albumin (E 3 -16G-BSA) serum (RIA No.1). This RIA was then compared with two other RIA methods employing [ 3 H]-labeled estriol-16-glucuronide (E 3 -16G) together with either anti-E 3 -16G-BAS serum (RIA No.2) or anti-estriol-16-glucuronide-2-azobenzoic acid-bovine serum albumin (E 3 -16G-2-BSA) serum (RIA No. 3). All three RIA's were accurate and precise, however, they differed in assay sensitivity and specificity. Most sensitive was RIA No.1 and least sensitive was RIA No.3. Both RIA's No.1 and 2 were less specific than RIA No.3. since unconjugated estriol and estrone 3-sulfate exhibited large and comparable cross-reactions in RIA's No.1 and 2, averaging 50% and 41% respectively. Furthermore, measurement of E 3 -16G in 10 different urine aliquots collected from non-pregnant women employing RIA's No. 1-3 showed that RIA's No. 1 and 2 yielded comparable results, however, the results obtained by RIA No.3 were, on the average, 26% lower than the mean of the values measured with RIA's No. 1 and 2. Consequently, RIA Bo.3 was used to measure daily 24-hour urinary E 3 -16G excretion in 7 women throughout an entire menstrual cycle. These data are in agreement with colorimetric and fluorimetric estimates of 24-h urinary estriol values throughout the menstrual cycle. The perovulatory rise of urinary E 3 -16G excretion, as quantitated by this RIA, is comparable to that of serum estradiol measured in the same 7 women, but peaks 1 to 2 days later than the serum estradiol surge. (author)

  11. Novel materials and methods for solid-phase extraction and liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Ambrose, Diana [Iowa State Univ., Ames, IA (United States)

    1997-06-24

    This report contains a general introduction which discusses solid-phase extraction and solid-phase micro-extraction as sample preparation techniques for high-performance liquid chromatography, which is also evaluated in the study. This report also contains the Conclusions section. Four sections have been removed and processed separately: silicalite as a sorbent for solid-phase extraction; a new, high-capacity carboxylic acid functionalized resin for solid-phase extraction; semi-micro solid-phase extraction of organic compounds from aqueous and biological samples; and the high-performance liquid chromatographic determination of drugs and metabolites in human serum and urine using direct injection and a unique molecular sieve.

  12. Three-site sandwich radioimmunoassay with monoclonal antibodies for a sensitive determination of human alpha-fetoprotein

    International Nuclear Information System (INIS)

    Nomura, M.; Imai, M.; Takahashi, K.; Kumakura, T.; Tachibana, K.; Aoyagi, S.; Usuda, S.; Nakamura, T.; Miyakawa, Y.; Mayumi, M.

    1983-01-01

    Utilizing monoclonal antibodies against human alpha-fetoprotein, 3 distinct antigenic determinants were identified. These antigenic determinants, provisionally designated a, b and c, were arranged in such a manner that the binding of one determinant with the corresponding antibody did not inhibit, or only barely inhibited the binding of antibodies directed to the other 2 determinants. Monoclonal antibodies with 3 different specificities were, therefore, applied to develop a sandwich-type solid-phase radioimmunoassay of the antigen in which wells were coated with anti-a, and radiolabeled anti-b together with radiolabeled anti-c was employed to detect the bound antigen. The 3-site sandwich radioimmunoassay involving 3 different determinants gave a higher sensitivity than 2-site assays in which only anti-b or anti-c was employed as a radiolabeled reagent, because the radioactivity of the 2 labeled antibodies was added on the antigen bound to immobilized anti-a. (Auth.)

  13. Utilization of highly robust and selective crosslinked polymeric ionic liquid-based sorbent coatings in direct-immersion solid-phase microextraction and high-performance liquid chromatography for determining polar organic pollutants in waters.

    Science.gov (United States)

    Pacheco-Fernández, Idaira; Najafi, Ali; Pino, Verónica; Anderson, Jared L; Ayala, Juan H; Afonso, Ana M

    2016-09-01

    Several crosslinked polymeric ionic liquid (PIL)-based sorbent coatings of different nature were prepared by UV polymerization onto nitinol wires. They were evaluated in a direct-immersion solid-phase microextraction (DI-SPME) method in combination with high-performance liquid chromatography (HPLC) and diode array detection (DAD). The studied PIL coatings contained either vinyl alkyl or vinylbenzyl imidazolium-based (ViCnIm- or ViBCnIm-) IL monomers with different anions, as well as different dicationic IL crosslinkers. The analytical performance of these PIL-based SPME coatings was firstly evaluated for the extraction of a group of 10 different model analytes, including hydrocarbons and phenols, while exhaustively comparing the performance with commercial SPME fibers such as polydimethylsyloxane (PDMS), polyacrylate (PA) and polydimethylsiloxane/divinylbenzene (PDMS/DVB), and using all fibers under optimized conditions. Those fibers exhibiting a high selectivity for polar compounds were selected to carry out an analytical method for a group of 5 alkylphenols, including bisphenol-A (BPA) and nonylphenol (n-NP). Under optimum conditions, average relative recoveries of 108% and inter-day precision values (3 non-consecutive days) lower than 19% were obtained for a spiked level of 10µgL(-1). Correlations coefficients for the overall method ranged between 0.990 and 0.999, and limits of detection were down to 1µgL(-1). Tap water, river water, and bottled water were analyzed to evaluate matrix effects. Comparison with the PA fiber was also performed in terms of analytical performance. Partition coefficients (logKfs) of the alkylphenols to the SPME coating varied from 1.69 to 2.45 for the most efficient PIL-based fiber, and from 1.58 to 2.30 for the PA fiber. These results agree with those obtained by the normalized calibration slopes, pointing out the affinity of these PILs-based coatings. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. A reactor/separator device for use in automated solid phase immunoassay

    International Nuclear Information System (INIS)

    Farina, P.R.; Ordonez, K.P.; Siewers, I.J.

    1979-01-01

    A reactor/separator device is described for use in automated solid phase immunoassay, including radioimmunoassays. The device is a column fitted at the bottom portion with a water impermeable disc which can hold, for example, immunoabsorbents, immobilized antisera or ion exchange resins. When the contents of the column supported by the disc are brought into contact with an aqueous phase containing reagents or reactants, a chemical reaction is initiated. After the reaction, centrifugally applied pressure forces the aqueous phase through the filter disc making it water permeable and separating a desired component for subsequent analysis. The reactor/separator device of the present invention permits kinetic solid phase assays (non-equilibrium conditions) to be carried out which would be difficult to perform by other conventional methods. (author)

  15. Radioimmuoassay study of antidigitoxin antibodies in liquid phase and after coupling on a solid phase

    International Nuclear Information System (INIS)

    Collignon, A.; German, A.; Scherrmann, J.M.; Bourdon, R.

    1983-01-01

    Antidigitoxin antibodies prepared by immunizing rabbits with a digitoxin-bovine serum albumin conjugate have been studied by radioimmunoassay in the native serum (homogeneous phase antibodies) and after coupling on glass beads (heterogeneous phase antibodies). Homogeneous phase antibodies present a satisfactory titer and affinity constant and react very specifically with digitoxin. Fixation of antibodies on a solid phase induce a loss of their immunoreactivity as it is showed by modification of the inhibition curves, by a greater sensitivity to the chemical structure of the tracer and by a decrease of the affinity constant. Reactionnal kinetic and sensitivity to the incubation temperature are not modified. Heterogeneous phase antibodies present a greater stability. Both antibodies types can be used for a digitoxin radioimmunoassay [fr

  16. Direct radioimmunoassay (RIA) of salivary testosterone: correlation with free and total serium testosterone

    International Nuclear Information System (INIS)

    Vittek, J.; L'Hommedieu, D.G.; Gordon, G.G.; Rappaport, S.C.; Southren, A.L.

    1985-01-01

    Simple and sensitive direct RIA for determination of salivary testosterone was developed by using RSL NOSOLVEX TM (125 1) kit produced by Radioassay System Laboratories (Carcon, California). In addition, a relationship between salivary and serum free and total testosterone concentrations was studied in randomly selected 45 healthy subjects, 5 females on oral contraceptive pills and 28 hypertensive patients on various treatment regimens. The lowest weight of testosterone detectable by the modified method was equivalent to 1 pg/ml of saliva, taking into account analytical variability. Intra- and interassay coefficients of variation were 5.09 +/- 2.7% and 8.2 +/- 5.9% respectively. Statistically significant correlations were found between salivary and serum free testosterone (r = 0.97) and salivary and serum total testosterone concentrations (r = 0.70 - 0.87). The exception to this was a group of hypertensive females in which no correlation (r = 0.14) between salivary and total serum testosterone was found. It is also of interest that, while salivary testosterone was significantly increased in subjects taking oral contraceptives and most of the hypertensive patients, the total serum testosterone concentration was in normal range. These findings suggest that the determination of salivary testosterone is a reliable method to detect changes in the concentration of available biologically active hormone in the circulation. 21 references, 4 figures, 1 table

  17. Direct radioimmunoassay of urinary estrogen and pregnanediol glucuronides during the menstrual cycle

    International Nuclear Information System (INIS)

    Stanczyk, F.Z.; Miyakawa, I.; Goebelsmann, U.

    1980-01-01

    Assays measuring immunoreactive estrone glucuronide (E 1 G), estradiol-3-glucuronide (E 2 -3G), estradiol-17β-glucuronide (E 2 -17G), estriol-3-glucuronide (E 3 -3G), estriol-16α-glucuronide (E 3 -16G), and pregnanediol-3α-glucuronide (Pd-3G) directly in diluted urine were developed and validated. These estrogen and pregnanediol glucuronide fractions were measured in aliquots of 24-hour and overnight samples of urine collected daily from seven women for one menstrual cycle. Urinary hormone excretion was correlated with daily serum estradiol (E 2 ), progesterone (P), and lutenizing hormonee (LH) levels. A sharp midcycle LH peak preceded by a preovulatory rise in serum E 2 and followed by luteal phase serum P levels were noted in each of the seven apparently ovulatory cycles. Twenty-four-hour and overnight urinary excretion patterns of estrogen glucuronides were similar to those of serum E 2 . Of the five estrogen glucuronide fractions tested, excretion of E 2 -17G exhibited the earliest and steepest ascending slope of the preovulatory estrogen surge and correlated best with serum E 2 levels. Urinary excretion of E 1 -G, E 2 -3G, and E 3 -16G also showed an early and steep preovulatory rise and preceded that of E 3 -3G, whereas urinary excretion of E 3 -3G exhibited the poorest correlation with serum E 2 concentrations. The urinary excretion of Pd-3G rose parallel to serum P levels and was markedly elevated 2 to 3 days after the midcycle LH peak in both 24-hour and overnight collections of urine. These results indicate that among the urinary estrogen conjugate fractions tested, E 2 -17G is the one that most suitably predicts ovulation

  18. Direct radioimmunoassay of urinary estrogen and pregnanediol glucuronides during the menstrual cycle

    Energy Technology Data Exchange (ETDEWEB)

    Stanczyk, F.Z.; Miyakawa, I.; Goebelsmann, U.

    1980-06-15

    Assays measuring immunoreactive estrone glucuronide (E/sub 1/G), estradiol-3-glucuronide (E/sub 2/-3G), estradiol-17..beta..-glucuronide (E/sub 2/-17G), estriol-3-glucuronide (E/sub 3/-3G), estriol-16..cap alpha..-glucuronide (E/sub 3/-16G), and pregnanediol-3..cap alpha..-glucuronide (Pd-3G) directly in diluted urine were developed and validated. These estrogen and pregnanediol glucuronide fractions were measured in aliquots of 24-hour and overnight samples of urine collected daily from seven women for one menstrual cycle. Urinary hormone excretion was correlated with daily serum estradiol (E/sub 2/), progesterone (P), and lutenizing hormonee (LH) levels. A sharp midcycle LH peak preceded by a preovulatory rise in serum E/sub 2/ and followed by luteal phase serum P levels were noted in each of the seven apparently ovulatory cycles. Twenty-four-hour and overnight urinary excretion patterns of estrogen glucuronides were similar to those of serum E/sub 2/. Of the five estrogen glucuronide fractions tested, excretion of E/sub 2/-17G exhibited the earliest and steepest ascending slope of the preovulatory estrogen surge and correlated best with serum E/sub 2/ levels. Urinary excretion of E/sub 1/-G, E/sub 2/-3G, and E/sub 3/-16G also showed an early and steep preovulatory rise and preceded that of E/sub 3/-3G, whereas urinary excretion of E/sub 3/-3G exhibited the poorest correlation with serum E/sub 2/ concentrations. The urinary excretion of Pd-3G rose parallel to serum P levels and was markedly elevated 2 to 3 days after the midcycle LH peak in both 24-hour and overnight collections of urine. These results indicate that among the urinary estrogen conjugate fractions tested, E/sub 2/-17G is the one that most suitably predicts ovulation.

  19. Radioimmunoassay apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Apparatus for performing a quantitative radioimmunoassay comprising: a substantially spherical bead for carrying an antibody and a gripper for gripping said bead, said gripper comprising an integrally formed unit having a single elongate handle portion and a plurality of resilient fingers arranged at the base of the handle so that when said bead is secured within said fingers, said bead may be freely rotated about any diametric axis of the bead. In particular the invention relates to an apparatus for a two site immunoradiometric assay for serum ferritin in human blood samples. (author)

  20. Solid-phase reductive amination for glycomic analysis.

    Science.gov (United States)

    Jiang, Kuan; Zhu, He; Xiao, Cong; Liu, Ding; Edmunds, Garrett; Wen, Liuqing; Ma, Cheng; Li, Jing; Wang, Peng George

    2017-04-15

    Reductive amination is an indispensable method for glycomic analysis, as it tremendously facilitates glycan characterization and quantification by coupling functional tags at the reducing ends of glycans. However, traditional in-solution derivatization based approach for the preparation of reductively aminated glycans is quite tedious and time-consuming. Here, a simpler and more efficient strategy termed solid-phase reductive amination was investigated. The general concept underlying this new approach is to streamline glycan extraction, derivatization, and purification on non-porous graphitized carbon sorbents. Neutral and sialylated standard glycans were utilized to test the feasibility of the solid-phase method. As results, almost complete labeling of those glycans with four common labels of aniline, 2-aminobenzamide (2-AB), 2-aminobenzoic acid (2-AA) and 2-amino-N-(2-aminoethyl)-benzamide (AEAB) was obtained, and negligible desialylation occurred during sample preparation. The labeled glycans derived from glycoproteins showed excellent reproducibility in high performance liquid chromatography (HPLC) and matrix assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) analysis. Direct comparisons based on fluorescent absorbance and relative quantification using isotopic labeling demonstrated that the solid-phase strategy enabled 20-30% increase in sample recovery. In short, the solid-phase strategy is simple, reproducible, efficient, and sensitive for glycan analysis. This method was also successfully applied for N-glycan profiling of HEK 293 cells with MALDI-TOF MS, showing its attractive application in the high-throughput analysis of mammalian glycome. Published by Elsevier B.V.

  1. Radioimmunoassay for thyroid stimulating hormone (TSH)

    International Nuclear Information System (INIS)

    1980-01-01

    An improved double antibody radioimmunoassay method is described for the determination of thyroid stimulating hormone (TSH) in biological and other fluids. Highly purified second antibody is immobilised on to hydrophilic, hydrolyzed polyacrylamide particles of a suspendable size to form a solid phase second antibody reagent. The immobilised second antibody reagent is used to precipitate the reaction product of the first antibody with labelled and unlabelled thyroid stimulating hormone (TSH-anti-TSH-complex) so as to produce a two-phase system which permits rapid and efficient separation of bound TSH in the solid phase from free TSH in the liquid phase. Details of the preparation of this novel second antibody-polyacrylamide reagent and of the assay procedure for human TSH are described. (U.K.)

  2. Utilization of a single antiserum for the direct radioimmunoassay of prostaglandins E and F in semen and prostaglandin F in amniotic fluid

    International Nuclear Information System (INIS)

    Clarke, A.H.; Ing, R.M.Y.; Jones, W.R.; Llewellyn-Jones, D.; Shutt, D.A.

    1974-01-01

    Antibodies to both prostaglandin F (PGF) and prostaglandin E (PGE) were raised in rabbits after they were immunized with prostaglandin F/sub 2a/ conjugated to bovine serum albumin (PGF/sub 2a/--BSA). The antisera were group specific although the antibodies to the F group of prostaglandins showed greater specificity than those to the E group. The antisera were sufficiently specific however to allow the direct radioimmunoassay of PGF and PGE in human semen and PGF in amniotic fluid during induced abortion. Specificity of the direct radioimmunoassay was checked by chromatographic separation of the prostaglandins prior to analysis. Estimation of the prostaglandins in the semen of 30 men attending the infertility clinic showed that 19 of the men had normal semen levels of PGE and PGF of 68 +- 7 (SE) and 6.0 +- 0.6 μg/ml respectively, as compared with data on normal fertile males, whilst the other 11 men had lower levels of 16 +- 2 (SE) and 0.8 +- 0.1 μg/ml respectively. Application of the method to amniotic fluid showed that the PGF concentration in amniotic fluid during the induction of abortion with extra-ovular saline increased from less than 0.6 ng/ml to 6.4 ng/ml when the induction-abortion intervals ranged from 6 to 48 hours. (U.S.)

  3. Apparatus for use in radioimmunoassays

    International Nuclear Information System (INIS)

    Chen, C-H.; Tsay, H-M.; Heyer, R.E.

    1979-01-01

    Apparatus for solid-phase antibody separation techniques used in radioimmunoassays is described in this invention. It consists of a rectangular prism tray with multiple wells protruding into its interior from one side. Near the base of the tray is an orifice used for creating evacuated condition within the structure. At the base of each well there is an orifice of such size and shape as to retain an aqueous liquid under given pressure conditions but permit the evacuation of this liquid at reduced pressure. The outlet of these orifices is in the shape of an inverted conical frustrum. Each of the wells contains an antibody coated disc of porous cellulose paper surrounded by a plastic support. The porous nature of the cellulose paper ensures contact between the antibody coating and the antigen. The use of antibody coated porous cellulose paper in combination with the vacuum operated apparatus simplifies the manipulative steps whilst still maintaining the sensitivity of the radioimmunoassay. It also obviates the need for aspiration and thus lessens the risk of contamination from one sample to another. (UK)

  4. Radioimmunoassay for thyroid-stimulating hormone (TSH)

    International Nuclear Information System (INIS)

    Blakemore, J.I.; Lewin, N.; Burgett, M.W.

    1978-01-01

    This invention provides a method for the radioimmunoassay of thyroid-stimulating hormone which utilizes a rapid and convenient version of a double antibody procedure. Highly purified second antibody is bound, by means of covalent bonds, to hydrolyzed polyacrylamide particles to produce a two-phase system. The solid phase comprises immobilized second antibody bound to the reaction product of labeled and unlabeled thyroid-stimulating hormone with the first antibody (first antibody-antigen complex) and the liquid phase comprises free (unbound) labeled and unlabeled thyroid-stimulating hormone. The two phases are separated and the radioactivity of either phase is measured

  5. A double antibody radioimmunoassay specific for placental alkaline phosphatase

    International Nuclear Information System (INIS)

    Dass, S.; Bagshawe, K.D.

    1984-01-01

    Placental alkaline phosphatase (PLAP) is normally found in enzymically measurable amounts in second and third trimester pregnancy serum. Its occurrence in sera and tumours from patients with malignant disease has led to the development of methods to specifically identify and quantitate the enzyme. Recently immunological techniques have been used, employing antibodies raised to purified PLAP; these include solid phase radioimmunoassays and enzyme-immunoassay. The development of a sensitive, specific, automated double-antibody radioimmunoassay for the measurement of PLAP in serum is reported. (Auth.)

  6. Automated Solid-Phase Radiofluorination Using Polymer-Supported Phosphazenes

    DEFF Research Database (Denmark)

    Mathiessen, Bente; Zhuravlev, Fedor

    2013-01-01

    of [18F]FDG. The combination of compact form factor, simplicity of [18F]F− recovery and processing, and column reusability can make solid phase radiofluorination an attractive radiochemistry platform for the emerging dose-on-demand instruments for bedside production of PET radiotracers.......The polymer supported phosphazene bases PS-P2tBu and the novel PS-P2PEG allowed for efficient extraction of [18F]F− from proton irradiated [18O]H2O and subsequent radiofluorination of a broad range of substrates directly on the resin. The highest radiochemical yields were obtained with aliphatic...

  7. Radioimmunoassay for detection of VP1 specific neutralizing antibodies of foot and mouse disease virus

    International Nuclear Information System (INIS)

    Patzer, E.J.; Jackson, M.L.; Moore, D.M.

    1985-01-01

    A solid-phase radioimmunoassay was developed for the detection of antibodies against a specific region of the VP1 protein of the A24 and O1 serotypes of foot and mouth disease virus. The antibody titers from the radioimmunoassay showed a positive correlation with neutralizing antibody titers determined by a mouse protection assay. The specificity of the assay resides in the peptide used as antigen. The assay is rapid, reproducible and does not require the use of whole virions. (orig.)

  8. Solid-phase peptide quantitation assay using labeled monoclonal antibody and glutaraldehyde fixation

    International Nuclear Information System (INIS)

    Kasprzyk, P.G.; Cuttitta, F.; Avis, I.; Nakanishi, Y.; Treston, A.; Wong, H.; Walsh, J.H.; Mulshine, J.L.

    1988-01-01

    A solid-phase radioimmunoassay utilizing iodinated peptide-specific monoclonal antibody as a detection system instead of labeled peptide has been developed. Regional specific monoclonal antibodies to either gastrin-releasing peptide or gastrin were used as models to validate the general application of our modified assay. Conditions for radioactive labeling of the monoclonal antibody were determined to minimize oxidant damage, which compromises the sensitivity of other reported peptide quantitation assays. Pretreatment of 96-well polyvinyl chloride test plates with a 5% glutaraldehyde solution resulted in consistent retention of sufficient target peptide on the solid-phase matrix to allow precise quantitation. This quantitative method is completed within 1 h of peptide solid phasing. Pretreatment of assay plates with glutaraldehyde increased binding of target peptide and maximized antibody binding by optimizing antigen presentation. The hypothesis that glutaraldehyde affects both peptide binding to the plate and orientation of the peptide was confirmed by analysis of several peptide analogs. These studies indicate that peptide binding was mediated through a free amino group leaving the carboxy-terminal portion of the target peptide accessible for antibody binding. It was observed that the length of the peptide also affects the amount of monoclonal antibody that will bind. Under the optimal conditions, results from quantitation of gastrin-releasing peptide in relevant samples agree well with those from previously reported techniques. Thus, we report here a modified microplate assay which may be generally applied for the rapid and sensitive quantitation of peptide hormones

  9. Solid-phase equilibria on Pluto's surface

    Science.gov (United States)

    Tan, Sugata P.; Kargel, Jeffrey S.

    2018-03-01

    Pluto's surface is covered by volatile ices that are in equilibrium with the atmosphere. Multicomponent phase equilibria may be calculated using a thermodynamic equation of state and, without additional assumptions, result in methane-rich and nitrogen-rich solid phases. The former is formed at temperature range between the atmospheric pressure-dependent sublimation and condensation points, while the latter is formed at temperatures lower than the sublimation point. The results, calculated for the observed 11 μbar atmospheric pressure and composition, are consistent with recent work derived from observations by New Horizons.

  10. Radioimmunoassay in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Ametov, A S

    1982-01-01

    A wide application of radioimmunoassay in clinical practice is shown. The main theoretical aspects of radioimmunoassay and the fields of application in clinical practice - endocrinology, oncology, allergology, cardiology, pharmacology, pediatrics, hematology, obstetrics and gynecology, are presented.

  11. Trypsin radioimmunoassay

    International Nuclear Information System (INIS)

    Scheithauer, R.; Wolf, F.; Tympner, F.

    1981-01-01

    In 29 patients with suspicion of pancreatic disease standard secretin-pancreozymin-test was performed parallel to trypsin determination by radioimmunoassay before and after stimulation with secretin. Mean serum trypsin in normal subjects was 175 ng BIT/ml (range 90-250), the maximum after stimulation being 20 minutes after secreting injection (range 110-550). Preliminary normal values are 270 ng BIT/ml for basal concentration and 650 ng BIT/ml for 20 min after secretin stimulation. In the group of normals there was no case of misinterpretation. In patients with several pathological parameters (n = 10) basal trypsin concentration was increased in 7 cases, the stimulated value was concordant with the definite diagnosis in every case. Significant advantage for diagnostics was derived in patients having had pancreatic diseases before, however being actually normal with respect to standard diagnostic parameters. All these patients revealed increased trypsin concentrations after stimulation and 50% of them showed increased basal values. Equivocal results were seen in patients with endstage pancreatitis as well as in case of obstruction during reduced secretion. (orig.) [de

  12. Evaluation of a solid-phase RIA technique and a solid-phase ELISA technique for demonstrating hepatitis-B surface antigen

    International Nuclear Information System (INIS)

    Vranckx, R.; Cole, J.; Peetermans, M.

    1978-01-01

    The sensitivities of a solid-phase radioimmunoassay (RIA), a solid-phase enzyme immunoassay (ELISA) and a haemagglutination test (RPHA) for the detection of the hepatitis-B surface antigen (HBsAg) were compared (1) by screening a panel of 300 sera (97 positives and 203 negatives), and (2) by titrating serial dilutions of 10 positive sera. Ninety-seven sera were positive by RIA, 95% were detected by ELISA and 81% were detected by RPHA. In the serial dilutions, the average end-points of the titrations were 0.005ng/ml for RIA, 0.01ng/ml for ELISA and 0.04 ng/ml for RPHA. It can be concluded that the sensitivity of the ELISA test is intermediate between that of the RIA and the RPHA. The ELISA and the RPHA tests seem to be a little more sensitive for the detection of subtype ay than for the detection of subtype ad. (author)

  13. Comparison of radioimmunoassay and ELISA methods for detection of antibodies to chromatin components

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, E; Cheng, N [North Carolina Univ., Chapel Hill (USA). Dept. of Bacteriology and Immunology

    1983-09-16

    A solid phase radioimmunoassay has been compared with an enzyme-linked immunosorbent assay (ELISA) for efficacy in measuring anti-chromatin antibodies. The low backgrounds achieved with the radioimmunoassay method produced a high signal-to-noise ratio and enabled detection of the human test antiserum at a dilution of 1:102,400. By contrast, the ELISA could detect the same antiserum only at a dilution of 1;3200 and above. The radioimmunoassay was consistently more sensitive than the ELSIA for detection of anti-chromatin antibodies in a number of human and mouse sera and ascites fluid containing a monoclonal antibody. Factors affecting sensitivity in both assays are discussed.

  14. Handbook of radioimmunoassay

    International Nuclear Information System (INIS)

    Abraham, G.E.

    1977-01-01

    This handbook provides clear, detailed descriptions of ways to set up radioimmunoassay procedures for a variety of polypeptides and low molecular weight compounds. It covers extensively the subjects of statistical evaluation of radioimmunoassay, instrumentation in radioimmunoassay, and radiation safety in the performance of radioimmunoassay. Related nonconventional methods are also discussed. Contributors to this handbook have presented their own procedures for performing the radioimmunoassay and their rationale for choosing particular reagents and conditions. Emphasis is on providing sufficient information to enable relatively inexperienced immunoassayists to set up assay systems with a minimum of difficulty

  15. Conjugated oestrogen during the menstrual cycle measured by a direct radioimmunoassay with an antiserum prepared against oestradiol-17-glucosiduronate-(C-6)-BSA conjugate

    Energy Technology Data Exchange (ETDEWEB)

    Honjo, H.; Otsubo, K.; Yasuda, J.; Kitawaki, J.; Okada, H. (Department of Obstetrics and Gynaecology, Kyoto Prefectural University of Medicine, Kyoto); Ohkubo, T.; Nambara, T. (Pharmaceutical Institute, Tohoku University, Sendai, Japan)

    1984-01-01

    Early morning and 24 h urine samples and serum were collected daily throughout the menstrual cycle in women. Urinary oestradiol-17-glucosiduronate (E/sub 2/-17G) was measured with a direct radioimmunoassay whose antiserum has been prepared against E/sub 2/-17-G-(C-6)-bovine serum albumin conjugate and was very specific. On the average, E/sub 2/-17-G in early morning and 24 h urine samples showed a prominent peak one day before the peak of urinary LH. The time relationship between these urinary E/sub 2/-17-G and serum E/sub 2/ levels and peaks was also investigated.

  16. Radioimmunoassay and enzyme-linked immunoassay of antibodies directed against lymphadenopathy-associated virus (LAV) proteins larger than the core protein (P24)

    International Nuclear Information System (INIS)

    Neurath, A.R.; Strick, N.; Lee, Y.S.; Nilsen, T.; Baker, L.; Sproul, P.; Rubinstein, P.; Taylor, P.; Stevens, C.E.; Gold, J.W.M.

    1985-01-01

    Molecular exclusion chromatography of crude LAV antigen preparations allows separation of most of P24 from larger proteins of LAV (PL). PL and 125 I- or beta-lactamase-labeled anti-LAV were used as reagents for radioimmunoassay (RIA) - or enzyme-linked immunoassay (ELISA) - inhibition tests to detect antibodies directed predominantly against PL (anti-PL). Among 257 individuals belonging to groups at high risk of developing AIDS, 117 (45.5%) were positive for anti-PL and 108 (42%) for anti-P24, respectively. The 2 individuals among 600 random blood donors found to be anti-P24-positive in the preceding study also had anti-PL in their serum. Sera from 500 additional blood donors were screened for anti-PL and 1 of these was positive. The implication of these findings for screening of blood donors is discussed. (Auth.)

  17. Radioimmunoassay and enzyme-linked immunoassay of antibodies directed against lymphadenopathy-associated virus (LAV) proteins larger than the core protein (P24)

    Energy Technology Data Exchange (ETDEWEB)

    Neurath, A R; Strick, N; Lee, Y S; Nilsen, T; Baker, L; Sproul, P; Rubinstein, P; Taylor, P; Stevens, C E; Gold, J W.M.

    1985-10-01

    Molecular exclusion chromatography of crude LAV antigen preparations allows separation of most of P24 from larger proteins of LAV (PL). PL and /sup 125/I- or beta-lactamase-labeled anti-LAV were used as reagents for radioimmunoassay (RIA) - or enzyme-linked immunoassay (ELISA) - inhibition tests to detect antibodies directed predominantly against PL (anti-PL). Among 257 individuals belonging to groups at high risk of developing AIDS, 117 (45.5%) were positive for anti-PL and 108 (42%) for anti-P24, respectively. The 2 individuals among 600 random blood donors found to be anti-P24-positive in the preceding study also had anti-PL in their serum. Sera from 500 additional blood donors were screened for anti-PL and 1 of these was positive. The implication of these findings for screening of blood donors is discussed. 17 refs.; 2 figs.; 1 table.

  18. Fluorine incorporation during Si solid phase epitaxy

    International Nuclear Information System (INIS)

    Impellizzeri, G.; Mirabella, S.; Romano, L.; Napolitani, E.; Carnera, A.; Grimaldi, M.G.; Priolo, F.

    2006-01-01

    We have investigated the F incorporation and segregation in preamorphized Si during solid phase epitaxy (SPE) at different temperatures and for several implanted-F energies and fluences. The Si samples were amorphized to a depth of 550 nm by implanting Si at liquid nitrogen temperature and then enriched with F at different energies (65-150 keV) and fluences (0.07-5 x 10 14 F/cm 2 ). Subsequently, the samples were regrown by SPE at different temperatures: 580, 700 and 800 deg. C. We have found that the amount of F incorporated after SPE strongly depends on the SPE temperature and on the energy and fluence of the implanted-F, opening the possibility to tailor the F profile during SPE

  19. A sensitive chain specific radioimmunoassay for human immunoglobulins using monoclonal antibodies

    International Nuclear Information System (INIS)

    Sikora, K.; Alderson, T.St.J.; Ellis, J.

    1983-01-01

    A sensitive radioimmunoassay is described for human immunoglobulins. This solid-phase assay uses commercially available monoclonal antibodies and is specific for different Ig chain types. Levels of less than 20 ng/ml Ig are detectable. The assay is suitable for the analysis of human hybridoma supernatants. (Auth.)

  20. SOLID-PHASE PEPTIDE SYNTHESIS OF ISOTOCIN WITH AMIDE ...

    African Journals Online (AJOL)

    SOLID-PHASE PEPTIDE SYNTHESIS OF ISOTOCIN WITH AMIDE OF ASPARAGINE PROTECTED WITH 1-TETRALINYL. TRIFLUOROMETHANESULPHONIC ACID (TFMSA) DEPROTECTION, CLEAVAGE AND AIR OXIDATION OF MERCAPTO GROUPS TO DISULPHIDE.

  1. Radioimmunoassay of measles virus hemagglutinin protein G

    International Nuclear Information System (INIS)

    Lund, G.A.; Salmi, A.A.

    1982-01-01

    Guinea pig and rabbit antisera from animals immunized with purified measles virus hemagglutinin (G) protein were used to establish a solid-phase four-layer radioimmunoassay for quantitative measurement of the G protein. The sensitivity of the assay was 2 ng of purified G protein, and 200 μg of protein from uninfected Vero cells neither decreased the sensitivity nor reacted non-specifically in the assay. Radioimmunoassay standard dose-response curves were established and unknown values interpolated from these using the logit program of a desktop computer. Using this procedure, a measles virus growth curve in infected Vero cells was determined by measurement of G protein production. Under these same conditions, hemagglutination was not sensitive enough to detect early hemagglutinin production. Viral antigens in canine distemper virus, Newcastle disease virus, parainfluenza viruses 1-4, simian virus 5, and respiratory syncytial virus-infected cell lysates did not cross-react in the radioimmunoassay. A small degree of cross-reactivity was detected with mumps viral antigens, both with Vero cell-derived (wild-type strain) and egg-derived (Enders strain) purified virus preparations and with a cell lysate antigen prepared from wild-type mumps virus-infected Vero cells. (Auth.)

  2. Radioimmunoassay of measles virus hemagglutinin protein G

    Energy Technology Data Exchange (ETDEWEB)

    Lund, G A; Salmi, A A [Turku Univ. (Finland)

    1982-08-01

    Guinea pig and rabbit antisera from animals immunized with purified measles virus hemagglutinin (G) protein were used to establish a solid-phase four-layer radioimmunoassay for quantitative measurement of the G protein. The sensitivity of the assay was 2 ng of purified G protein, and 200 ..mu..g of protein from uninfected Vero cells neither decreased the sensitivity nor reacted non-specifically in the assay. Radioimmunoassay standard dose-response curves were established and unknown values interpolated from these using the logit program of a desktop computer. Using this procedure, a measles virus growth curve in infected Vero cells was determined by measurement of G protein production. Under these same conditions, hemagglutination was not sensitive enough to detect early hemagglutinin production. Viral antigens in canine distemper virus, Newcastle disease virus, parainfluenza viruses 1-4, simian virus 5, and respiratory syncytial virus-infected cell lysates did not cross-react in the radioimmunoassay. A small degree of cross-reactivity was detected with mumps viral antigens, both with Vero cell-derived (wild-type strain) and egg-derived (Enders strain) purified virus preparations and with a cell lysate antigen prepared from wild-type mumps virus-infected Vero cells.

  3. Two-dimensional solid-phase extraction strategy for the selective enrichment of aminoglycosides in milk.

    Science.gov (United States)

    Shen, Aijin; Wei, Jie; Yan, Jingyu; Jin, Gaowa; Ding, Junjie; Yang, Bingcheng; Guo, Zhimou; Zhang, Feifang; Liang, Xinmiao

    2017-03-01

    An orthogonal two-dimensional solid-phase extraction strategy was established for the selective enrichment of three aminoglycosides including spectinomycin, streptomycin, and dihydrostreptomycin in milk. A reversed-phase liquid chromatography material (C 18 ) and a weak cation-exchange material (TGA) were integrated in a single solid-phase extraction cartridge. The feasibility of two-dimensional clean-up procedure that experienced two-step adsorption, two-step rinsing, and two-step elution was systematically investigated. Based on the orthogonality of reversed-phase and weak cation-exchange procedures, the two-dimensional solid-phase extraction strategy could minimize the interference from the hydrophobic matrix existing in traditional reversed-phase solid-phase extraction. In addition, high ionic strength in the extracts could be effectively removed before the second dimension of weak cation-exchange solid-phase extraction. Combined with liquid chromatography and tandem mass spectrometry, the optimized procedure was validated according to the European Union Commission directive 2002/657/EC. A good performance was achieved in terms of linearity, recovery, precision, decision limit, and detection capability in milk. Finally, the optimized two-dimensional clean-up procedure incorporated with liquid chromatography and tandem mass spectrometry was successfully applied to the rapid monitoring of aminoglycoside residues in milk. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Serum 3,3'-L-diiodothyronine, a direct radioimmunoassay in human serum: method and clinical results

    International Nuclear Information System (INIS)

    Burger, A.; Sakoloff, C.

    1977-01-01

    A specific radioimmunoassay for 3,3'-diiodothyronine (T 2 ) is described which is capable of detecting as little as 1.3 ng/dl. The antiserum recognizes mainly T 2 ; biliary conjugates of T 2 bind slightly to the antibody. The intraassay and interassay coefficients of variation were, respectively, 5.7% and 13.1%. T 2 was detected in the serum of hypothyroid patients treated with triiodothyronine (T 3 ) and in euthyroid subjects treated with reverse triiodothyronine (rT 3 ). These results suggest that both T 3 and rT 3 are deiodinated to T 2 . Serum concentrations of T 2 in normal subjects decreased with age. Between 20 and 40 years the mean concentration was 4.3 +- 2.0 ng/dl (2 SD), between 41 and 60 years it varied from 1.9 to 5.8 ng/dl (3.8 +- 0.3 ng/dl, SE) and in elderly subjects have 60 years concentrations varied from unmeasurable to 4 ng/dl (2.9 +- 0.4 ng/dl, SE). Low serum T 2 concentrations were found in anorexia nervosa (2.5 +- 0.3 ng/dl, SE). In hypothyroidism the serum concentrations were low or unmeasurable. As most of the hypothyroid subjects were elderly their serum T 2 concentrations overlapped with the low values found in the elderly euthyroid subjects. In classical hyperthyroidism serum T 2 concentrations were greatly increased (3.3 to 31 ng/dl (11.8 +- 2.7 ng/dl, SE) but in ''T 3 toxicosis'' the concentrations were only modestly increased

  5. Solid-phase extraction of carotenoids.

    Science.gov (United States)

    Shen, Yao; Hu, Yumin; Huang, Ke; Yin, Shi'an; Chen, Bo; Yao, Shouzhuo

    2009-07-24

    In this work, solid-phase extraction (SPE) trapping performance of lutein and beta-carotene, which were used as the model molecules of carotenoids, was investigated. The absorption, elution, and enrichment of carotenoids on SPE cartridges with four different sorbents, i.e. C(30), C(18), diol, and silica, were compared respectively with the help of frontal analysis technique. The high retentions of both lutein and beta-carotene were achieved on the C(18) and C(30) cartridges. The diol and silica cartridges only had good retention for lutein. The optimized SPE method for sample pretreatment for the carotenoids analysis was obtained after the investigation of trapping performance. The method was applied successfully to the analysis of biological sample, i.e. serum and human breast milk. The recovery, accuracy, and precision of SPE method comparing with those of traditional liquid-liquid extraction (LLE) method for the sample pretreatment for the analysis of carotenoids owned a number of advantages such as rapid, no chloroform used, and accurate versus LLE.

  6. Combinatorial Solid-Phase Synthesis of Balanol Analogues

    DEFF Research Database (Denmark)

    Nielsen, John; Lyngsø, Lars Ole

    1996-01-01

    The natural product balanol has served as a template for the design and synthesis of a combinatorial library using solid-phase chemistry. Using a retrosynthetic analysis, the structural analogues have been assembled from three relatively accessible building blocks. The solid-phase chemistry inclu...

  7. Role of nanoparticles in analytical solid phase microextraction (SPME)

    NARCIS (Netherlands)

    Zielinska, K.; Leeuwen, van H.P.

    2013-01-01

    Solid phase microextraction (SPME) is commonly used to measure the free concentration of fairly hydrophobic substances in aqueous media on the basis of their partitioning between sample solution and a solid phase. Here we study the role of nanoparticles that may sorb the analyte in the sample

  8. Solid-phase cloning for high-throughput assembly of single and multiple DNA parts

    DEFF Research Database (Denmark)

    Lundqvist, Magnus; Edfors, Fredrik; Sivertsson, Åsa

    2015-01-01

    We describe solid-phase cloning (SPC) for high-throughput assembly of expression plasmids. Our method allows PCR products to be put directly into a liquid handler for capture and purification using paramagnetic streptavidin beads and conversion into constructs by subsequent cloning reactions. We ...

  9. Determination of phenobarbital by radioimmunoassay

    International Nuclear Information System (INIS)

    Yamaoka, A.; Takatori, T.

    1979-01-01

    A radioimmunoassay for phenobarbital has been studied. Antiphenobarbital antisera were obtained by repeated immunization of rabbits with p-succinamidophenobarbital conjugated to bovine serum albumin. Less than 0.2 pmol of phenobarbital could be measured by this procedure. The specificity of the antibodies was directed to substituents on the nitrogen atoms of the barbituric rings as well as to substituents at the carbon 5-position of the ring. (Auth.)

  10. Solid-phase extraction versus matrix solid-phase dispersion: Application to white grapes.

    Science.gov (United States)

    Dopico-García, M S; Valentão, P; Jagodziñska, A; Klepczyñska, J; Guerra, L; Andrade, P B; Seabra, R M

    2007-11-15

    The use of matrix solid-phase dispersion (MSPD) was tested to, separately, extract phenolic compounds and organic acids from white grapes. This method was compared with a more conventional analytical method previously developed that combines solid liquid extraction (SL) to simultaneously extract phenolic compounds and organic acids followed by a solid-phase extraction (SPE) to separate the two types of compounds. Although the results were qualitatively similar for both techniques, the levels of extracted compounds were in general quite lower on using MSPD, especially for organic acids. Therefore, SL-SPE method was preferred to analyse white "Vinho Verde" grapes. Twenty samples of 10 different varieties (Alvarinho, Avesso, Asal-Branco, Batoca, Douradinha, Esganoso de Castelo Paiva, Loureiro, Pedernã, Rabigato and Trajadura) from four different locations in Minho (Portugal) were analysed in order to study the effects of variety and origin on the profile of the above mentioned compounds. Principal component analysis (PCA) was applied separately to establish the main sources of variability present in the data sets for phenolic compounds, organic acids and for the global data. PCA of phenolic compounds accounted for the highest variability (77.9%) with two PCs, enabling characterization of the varieties of samples according to their higher content in flavonol derivatives or epicatechin. Additionally, a strong effect of sample origin was observed. Stepwise linear discriminant analysis (SLDA) was used for differentiation of grapes according to the origin and variety, resulting in a correct classification of 100 and 70%, respectively.

  11. Air sampling with solid phase microextraction

    Science.gov (United States)

    Martos, Perry Anthony

    There is an increasing need for simple yet accurate air sampling methods. The acceptance of new air sampling methods requires compatibility with conventional chromatographic equipment, and the new methods have to be environmentally friendly, simple to use, yet with equal, or better, detection limits, accuracy and precision than standard methods. Solid phase microextraction (SPME) satisfies the conditions for new air sampling methods. Analyte detection limits, accuracy and precision of analysis with SPME are typically better than with any conventional air sampling methods. Yet, air sampling with SPME requires no pumps, solvents, is re-usable, extremely simple to use, is completely compatible with current chromatographic equipment, and requires a small capital investment. The first SPME fiber coating used in this study was poly(dimethylsiloxane) (PDMS), a hydrophobic liquid film, to sample a large range of airborne hydrocarbons such as benzene and octane. Quantification without an external calibration procedure is possible with this coating. Well understood are the physical and chemical properties of this coating, which are quite similar to those of the siloxane stationary phase used in capillary columns. The log of analyte distribution coefficients for PDMS are linearly related to chromatographic retention indices and to the inverse of temperature. Therefore, the actual chromatogram from the analysis of the PDMS air sampler will yield the calibration parameters which are used to quantify unknown airborne analyte concentrations (ppb v to ppm v range). The second fiber coating used in this study was PDMS/divinyl benzene (PDMS/DVB) onto which o-(2,3,4,5,6- pentafluorobenzyl) hydroxylamine (PFBHA) was adsorbed for the on-fiber derivatization of gaseous formaldehyde (ppb v range), with and without external calibration. The oxime formed from the reaction can be detected with conventional gas chromatographic detectors. Typical grab sampling times were as small as 5 seconds

  12. A sensitive radioimmunoassay for fentanyl

    International Nuclear Information System (INIS)

    Michiels, M.; Hendriks, R.; Heykants, J.

    1977-01-01

    Antiserum to fentanyl was obtained in rabbits repeatedly injected with carboxyfentanyl conjugated to bovine serum albumin. Using the antiserum, a highly sensitive radioimmunoassay has been developed, based on the dextran-coated charcoal method. It proved possible to assay the drug directly in plasma, in amounts as small as 30 picogram in 0.5 ml. The antibody was highly specific for fentanyl and no cross-reaction was observed with its major metabolites. This sensitive and specific radioimmunoassay method was employed to determine fentanyl in plasma from six volunteers after an intravenous bolus of 0.2 mg, and in plasma from dogs treated both intravenously and subcutaneously with 0.02 mg/kg. The plasma level of fentanyl could be followed for up to 6 h after a therapeutic dose in dogs and man. (orig.) [de

  13. Radioimmunoassay of total IgE and allergen-specific IgE antibodies with a uniform indicator system in allergies of childhood

    International Nuclear Information System (INIS)

    Struy, H.; Schuster, R.; Sollich, V.; Thal, W.; Morenz, J.

    1984-01-01

    Solid-phase radioimmunoassays for the determination of allergen-specific and total IgE have been developed. In an indirect solid-phase radioimmunoassay for the measurement of allergen-specific antibodies PVC blisters coated with allergens and in a sandwich solid-phase radioimmunoassay blisters coated with antihuman IgE antibodies are incubated sequentially with patient serum, unlabelled antihuman IgE from rabbits purified by affinity chromatography, and finally with antirabbitglobulin from sheep. Antirabbitglobuline was purified by immunoadsorption. The 125 I-labelled antibody with a specific activity of 30 kBq/μg antibody protein could be used universally for the determination of antibodies of each immunoglobulin class. In 160 patients mostly with seasonal asthma these assays supported RAST and PRIST kits and were helpful in the diagnosis of atopic diseases. (author)

  14. Radioimmunoassay for chicken avidin. Comparison with a (/sup 14/C)biotin-binding method

    Energy Technology Data Exchange (ETDEWEB)

    Kulomaa, M S; Elo, H A; Tuohimaa, P J [Tampere Univ. of Tech. (Finland)

    1978-11-01

    A double-antibody solid-phase radioimmunoassay for chicken avidin is reported. Avidin was labelled with /sup 125/I by the chloramine-T method. The bound and free avidin were separated with a second antibody bound to a solid matrix. In the logit-log scale the standard curve was linear from 1-2 to 100-200ng of avidin/ml. Cross-reaction of ovalbumin was less than 0.015%. Saturation of biotin-binding sites of avidin with an excess of biotin decreased radioimmunoassay values by about 15%. Recovery studies indicated that avidin can be assayed from all chicken tissues studied with radioimmunoassay, whereas the (/sup 14/C)biotin/bentonite method gave poor recoveries for avidin in the liver and kidney. Radioimmunoassay and the (/sup 14/C)biotin/bentonite method gave similar concentrations for oviduct avidin.

  15. Development and Application of Solid Phase Extraction Method for ...

    African Journals Online (AJOL)

    NICO

    for the addition of organic modifier, sample load volume, conditioning solvent, washing solvent and ... Solid phase extraction, polycyclic aromatic hydrocarbons, water samples, ... such as polymeric, activated carbon or silica modified with.

  16. Determination of 8 Synthetic Food Dyes by Solid Phase Extraction ...

    African Journals Online (AJOL)

    Keywords: Synthetic colors, Food, Fruit flavored drinks, Solid phase extraction, RP-HPLC. Tropical Journal of ..... food dyes by thin-layer chromatography-fast atom bombardment ... food dyes in soft drinks containing natural pigments by.

  17. Solid phase extraction method for determination of mitragynine in ...

    African Journals Online (AJOL)

    All rights reserved. ... 1Department of Pharmacology, 2Department of Applied Science, 3Police Forensic Science Center 10, Yala 95000, 4Natural ... Purpose: To develop a solid phase extraction (SPE) method that utilizes reverse-phase high.

  18. Application of solid-phase microextraction in analytical toxicology.

    Science.gov (United States)

    Pragst, Fritz

    2007-08-01

    Solid-phase microextraction (SPME) is a miniaturized and solvent-free sample preparation technique for chromatographic-spectrometric analysis by which the analytes are extracted from a gaseous or liquid sample by absorption in, or adsorption on, a thin polymer coating fixed to the solid surface of a fiber, inside an injection needle or inside a capillary. In this paper, the present state of practical performance and of applications of SPME to the analysis of blood, urine, oral fluid and hair in clinical and forensic toxicology is reviewed. The commercial coatings for fibers or needles have not essentially changed for many years, but there are interesting laboratory developments, such as conductive polypyrrole coatings for electrochemically controlled SPME of anions or cations and coatings with restricted-access properties for direct extraction from whole blood or immunoaffinity SPME. In-tube SPME uses segments of commercial gas chromatography (GC) capillaries for highly efficient extraction by repeated aspiration-ejection cycles of the liquid sample. It can be easily automated in combination with liquid chromatography but, as it is very sensitive to capillary plugging, it requires completely homogeneous liquid samples. In contrast, fiber-based SPME has not yet been performed automatically in combination with high-performance liquid chromatography. The headspace extractions on fibers or needles (solid-phase dynamic extraction) combined with GC methods are the most advantageous versions of SPME because of very pure extracts and the availability of automatic samplers. Surprisingly, substances with quite high boiling points, such as tricyclic antidepressants or phenothiazines, can be measured by headspace SPME from aqueous samples. The applicability and sensitivity of SPME was essentially extended by in-sample or on-fiber derivatization. The different modes of SPME were applied to analysis of solvents and inhalation narcotics, amphetamines, cocaine and metabolites

  19. Evaluation of a solid phase R.I.A. technique and solid phase E.L.I.S.A. technique for the demonstration of hepatitis B surface antigen

    International Nuclear Information System (INIS)

    Vranckx, R.; Cole, J.; Peetermans, M.

    1977-01-01

    We compared the sensitivity of a solidphase radio-immunoassay (R.I.A.), a solid-phase enzyme-immunoassay (E.L.I.S.A.) and a hemagglutination test (R.P.H.A.) for the detection of the HBs Ag in two ways: 1) by screening a panel of 300 sera (97 positives and 203 negatives) 2) by titrating serial dilutions of 10 positive sera. Ninety seven sera were positive by R.I.A., 95% were detected by E.L.I.S.A. and 81% were detected by R.P.H.A. In the serial dilutions the average end points of the titration were for R.I.A. 0.005 ng/ml, for E.L.I.S.A. 0,01 ng/ml and for R.P.H.A. 0.04 ng/ml. It can be concluded that the sensitivity of the E.L.I.S.A. test is intermediate between the sensitivity of the R.I.A. and the sensitivity of the R.P.H.A. The E.L.I.S.A. and the R.P.H.A. tests seam to be a little more sensitive for the detection of subtype ay than the detection of subtype ad. (orig.) [de

  20. Micro versus macro solid phase extraction for monitoring water contaminants: a preliminary study using trihalomethanes.

    Science.gov (United States)

    Alexandrou, Lydon D; Spencer, Michelle J S; Morrison, Paul D; Meehan, Barry J; Jones, Oliver A H

    2015-04-15

    Solid phase extraction is one of the most commonly used pre-concentration and cleanup steps in environmental science. However, traditional methods need electrically powered pumps, can use large volumes of solvent (if multiple samples are run), and require several hours to filter a sample. Additionally, if the cartridge is open to the air volatile compounds may be lost and sample integrity compromised. In contrast, micro cartridge based solid phase extraction can be completed in less than 2 min by hand, uses only microlitres of solvent and provides comparable concentration factors to established methods. It is also an enclosed system so volatile components are not lost. The sample can also be eluted directly into a detector (e.g. a mass spectrometer) if required. However, the technology is new and has not been much used for environmental analysis. In this study we compare traditional (macro) and the new micro solid phase extraction for the analysis of four common volatile trihalomethanes (trichloromethane, bromodichloromethane, dibromochloromethane and tribromomethane). The results demonstrate that micro solid phase extraction is faster and cheaper than traditional methods with similar recovery rates for the target compounds. This method shows potential for further development in a range of applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. A simplified radiometabolite analysis procedure for PET radioligands using a solid phase extraction with micellar medium

    International Nuclear Information System (INIS)

    Nakao, Ryuji; Halldin, Christer

    2013-01-01

    A solid phase extraction method has been developed for simple and high-speed direct determination of PET radioligands in plasma. Methods: This methodology makes use of a micellar medium and a solid-phase extraction cartridge for displacement of plasma protein bound radioligand and separation of PET radioligands from their radiometabolites without significant preparation. The plasma samples taken from monkey or human during PET measurements were mixed with a micellar eluent containing an anionic surfactant sodium dodecyl sulphate and loaded onto SPE cartridges. The amount of radioactivity corresponding to parent radioligand (retained on the cartridge) and its radioactive metabolites (eluted with micellar eluent) was measured. Results: Under the optimized conditions, excellent separation of target PET radioligands from their radiometabolites was achieved with a single elution and short run-time of 1 min. This method was successfully applied to study the metabolism for 11 C-labelled radioligands in human or monkey plasma. The amount of parent PET radioligands estimated by micellar solid phase extraction strongly corresponded with that determined by radio-LC. The improved throughput permitted the analysis of a large number of plasma samples (up to 13 samples per one PET study) for accurate estimation of metabolite-corrected input function during quantitative PET imaging studies. Conclusion: Solid phase extraction together with micellar medium is fast, sensitive and easy to use, and therefore it is an attractive alternative method to determine relative composition of PET radioligands in plasma

  2. A radioimmunoassay for the detection of adrenal autoantibodies

    International Nuclear Information System (INIS)

    Kosowicz, J.; Gryczynska, M.; Bottazzo, G.F.

    1986-01-01

    A solid phase radioimmunoassay for adrenal antibodies is described. In the assay plastic tubes coated with adrenal microsomes (100 μg/ml) were incubated with human sera diluted from 1:50 to 1:5000 and the retained antibodies detected by subsequent incubation with 125 I-labelled protein A. The method was precise over the range of serum dilution of 1:250 to 1:5000. In the group of 30 patients with Addison's disease 19 had positive results in adrenal antibody radioimmunoassay (RIA). Comparative studies of RIA and immunofluorescence (IFL) revealed that there was partial correlation of adrenal antibody results in patients with high titre antibodies whereas RIA usually was more sensitive than IFL in patients with low titre antibodies. Computerized tomography (CT) displayed bilateral adrenal atrophy in most patients who had adrenal antibodies. On the other hand, patients with low RIA results and negative IFL antibodies had predominantly adrenal calcifications on scans. (author)

  3. Detection of gonococcal antigens in urine by radioimmunoassay

    International Nuclear Information System (INIS)

    Thornley, M.J.; Wilson, D.V.; Hormaeche, R.D. de; Coombs, R.R.A.; Oates, J.K.

    1979-01-01

    A method of detecting gonococcal antigens by solid-phase radioimmunoassay with radioactively labelled antibody is described. A specificity test has been developed that enables this method to be used to detect gonococcal antigens in urine sediments. When sediments from samples of urine from male patients with gonorrhoea were tested, 31 (74%) of 42 gave positive results, clearly distinguishing them from sediments from urine samples from men with non-specific urethritis, none of which was positive. Ten of 14 urine sediments from urine samples from women with gonorrhoea gave positive results, as did 3 of 18 sediments from urine samples from women patients without gonorrhoea.These experiments demonstrate that gonococcal antigens can be detected in urine by radioimmunoassay; the method could be useful in diagnosis if, after refinement, its sensitivity and specificity were to be increased. (author)

  4. IN SITU SOLID-PHASE EXTRACTION AND ANALYSIS OF ...

    Science.gov (United States)

    Fragrance materials, such as synthetic musks in aqueous samples, are normally analyzed by GC/MS in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of 1-L samples. A 1-L sample, however, usually provides too little analyte for full-scan data acquisition.We have developed an on-site extraction method for extracting synthetic musks from 60 L of wastewater effluent. Such a large sample volume permits high-quality, full-scan mass spectra to be obtained for various synthetic musk compounds. Quantification of these compounds was conveniently achieved from the full-scan data directly, without preparing SIM descriptors for each compound to acquire SIM data. The research focused on in the subtasks is the development and application of state-of the-art technologies to meet the needs of the public, Office of Water, and ORD in the area of Water Quality. Located In the subtasks are the various research projects being performed in support of this Task and more in-depth coverage of each project. Briefly, each project's objective is stated below.Subtask 1: To integrate state-of-the-art technologies (polar organic chemical integrative samplers, advanced solid-phase extraction methodologies with liquid chromatography/electrospray/mass spectrometry) and apply them to studying the sources and fate of a select list of PPCPs. Application and improvement of analytical methodologies that can detect non-volatile, polar, water-s

  5. ON-SITE SOLID-PHASE EXTRACTION AND LABORATORY ...

    Science.gov (United States)

    Fragrance materials such as synthetic musks in aqueous samples, are normally determined by gas chromatography/mass spectrometry in the selected ion monitoring (SIM) mode to provide maximum sensitivity after liquid-liquid extraction of I -L samples. Full-scan mass spectra are required to verify that a target analyte has been found by comparison with the mass spectra of fragrance compounds in the NIST mass spectral library. A I -L sample usually provides insufficient analyte for full scan data acquisition. This paper describes an on-site extraction method developed at the U.S. Environmental Protection Agency (USEPA)- Las Vegas Nevada - for synthetic musks from 60 L of wastewater effluent. Such a large sample volume permits high-quality, full-scan mass spectra to be obtained for a wide array of synthetic musks. Quantification of these compounds was achieved from the full-scan data directly, without the need to acquire SIM data. The detection limits obtained with this method are an order of magnitude lower than those obtained from liquid-liquid and other solid phase extraction methods. This method is highly reproducible, and recoveries ranged from 80 to 97% in spiked sewage treatment plant effluent. The high rate of sorbent-sample mass transfer eliminated the need for a methanolic activation step, which reduced extraction time, labor, and solvent use, More samples could be extracted in the field at lower cost. After swnple extraction, the light- weight cartridges ar

  6. Radioimmunoassay for the detection of Australia-SH antigen

    Energy Technology Data Exchange (ETDEWEB)

    Gerhardt, H [Giessen Univ. (Germany, F.R.). Zentrum fuer Innere Medizin

    1974-06-01

    Among infectious diseases, hepatitis presents a great problem in all countries with a high medical standard. The number of Australia antigen-positive cases rises from year to year, due to the increase in drug-fixer hepatitis and blood transfusions. Highly sensitive and at the same time practicable methods are therefore required for the identification of Australia antigen carriers and their elimination as blood donors. The most sensitive of all currently used tests for the detection of Australia antigen is the 'solid phase' radioimmunoassay since it permits an objective and quantitative measurement of the antigen.

  7. Radioimmunoassay for human ACTH

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, S; Oyama, H; Tenku, A; Horino, M [Kawasaki Medicial School, Kurashiki, Okayama (Japan); Kobayashi, K

    1977-03-01

    A radioimmunoassay method for human adrenocorticotropic hormone (ACTH) is described. The antiserum was produced in a guinea pig by multiple injections of a total of 1 mg of porcine ACTH adsorbed with CM-cellulose and mixed with complete Freund's adjuvant. The antiserum used for this study at a final dilution of 1:500,000 was obtained from a guinea pig after 10 immunizations. A highly purified native ACTH (Li, ..cap alpha.. sub(h)sup(1-39) ACTH) was used as an assay standard and a tracer hormone. Separation of free and bound hormone was achieved by dextran coated charcoal. Extraction of ACTH from plasma samples was performed by Donald's method modified with silicic acid. The antibody appeared to be directed against the C-terminal portion of the hormone molecule and showed no significant reaction with other pituitary hormones (GH, TSH, LH, FSH, Hpr, Oxytocin, Arginine-and Lysine-Vasopressin). Plasma ACTH levels of 5 healthy subjects at nine o'clock averaged 32 +- 8.5 pg/ml (M +- SD). Plasma ACTH concentrations in a case of Sheehan's syndrome and of an untreated adrenogenital syndrome at nine o'clock were less than 20 and 194 pg/ml, respectively. A case of Cushing's syndrome accompanied with bilateral nodular hyperplasia of the adrenal cortex showed diminished diurnal variation and normal levels of plasma ACTH. In contrast, elevated plasma ACTH levels and lack of diurnal rhythm of ACTH secretion were observed in a suspected case of Cushing's disease.

  8. Preparation of bioconjugates by solid-phase conjugation to ion exchange matrix-adsorbed carrier proteins

    DEFF Research Database (Denmark)

    Houen, G.; Olsen, D.T.; Hansen, P.R.

    2003-01-01

    A solid-phase conjugation method utilizing carrier protein bound to an ion exchange matrix was developed. Ovalbumin was adsorbed to an anion exchange matrix using a batch procedure, and the immobilized protein was then derivatized with iodoacetic acid N-hydroxysuccinimid ester. The activated......, and immunization experiments with the eluted conjugates showed that the more substituted conjugates gave rise to the highest titers of glutathione antibodies. Direct immunization with the conjugates adsorbed to the ion exchange matrix was possible and gave rise to high titers of glutathione antibodies. Conjugates...... of ovalbumin and various peptides were prepared in a similar manner and used for production of peptide antisera by direct immunization with the conjugates bound to the ion exchanger. Advantages of the method are its solid-phase nature, allowing fast and efficient reactions and intermediate washings...

  9. Assessment of the specificity of norethisterone radioimmunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Bedolla-Tovar, N; Rahman, S A; Cekan, S Z; Diczfalusy, E [Swedish Medical Research Council, Karolinska Hospital, Stockholm

    1978-06-01

    It is concluded that (1) the significance of cross- reaction studies as well as that of the parallelism test for the assessment of the over-all specificity of the assay is limited, (2) a single chromatography prior to the radioimmunoassay proper improves the assay specificity, but may not be sufficient to remove all interfering compounds, (3) a comparison of the direct and chromatographic assay procedures using several antisera is useful for the selection of the relatively most specific radioimmunoassay procedure. In the present study, this is the technique employing either antiserum C or antiserum D, the latter, however, only after chromatography.

  10. Linkage of biomolecules to solid phases for immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Topics covered by this lecture include a brief review of the principal methods of linkage of biomolecules to solid phase matrices. Copies of the key self explanatory slides are presented as figures together with reprints of two publications by the author dealing with a preferred chemistry for the covalent linkage of antibodies to hydroxyl and amino functional groups and the effects of changes in solid phase matrix and antibody coupling chemistry on the performance of a typical excess reagent immunoassay for thyroid stimulating hormone

  11. Solid-phase synthesis of complex and pharmacologically interesting heterocycles

    DEFF Research Database (Denmark)

    Nielsen, Thomas Eiland

    2009-01-01

    Efficient routes for the creation of heterocycles continue to be one of the primary goals for solid-phase synthesis. Recent advances in this field rely most notably on transition-metal-catalysis and N-acyliminium chemistry to mediate a range of cyclization processes for the generation of compounds...... with significant structural complexity and diversity. This review describes some of the most systematic solid-phase approaches that are potentially suited for pharmaceutical applications, that is, the methods described are useful for the synthesis of compound collections, and exhibit tunable stereochemistry...

  12. Preparation of iodine - 125 - labeled insulin for radioimmunoassay: comparison of chloramine T and iodogen iodination

    International Nuclear Information System (INIS)

    Toledo e Souza, I.T. de; Giannella Neto, D.; Wajchenberg, B.L.

    1988-05-01

    Stoichiometric iodination of porcine insulin was performed to the general method of Hunter and Greenwood with modifications recommended by Roth. These method was compared with radioidination using Iodogen. Films of Iodogen react rapidly in the solid phase with aqueous mixtures of I - and proteins. For two methods satisfactory activity of the labeled porcine insulin was obtained and characteristics of the radioimmunoassay were studied. (author) [pt

  13. Radioimmunoassay for tetrahydrocortisol

    International Nuclear Information System (INIS)

    Mougey, E.H.

    1978-01-01

    A radioimmunoassay for urinary tetrahydrocortisol (THF) is described. Antibodies were produced in rabbits against a THF-monohemisuccinate:bovine serum albumin conjugate. The radioimmunoassay procedure involves enzymic hydrolysis of the urine, extraction with ethyl acetate, radioimmunoassay, and separation of free from bound steroid with Somogyi reagents. The antibody showed some cross-reaction with tetrahydro substance S (36%) which does not occur in urine in appreciable amounts and with tetrahydrocortisone (10%) which does. An analysis of monkey urine extracts before and after tlc purification revealed that the THF antibody was specific enough to permit assay of urines for THF during stress experiments without a purification step. THF values obtained correlated very highly with 17-hydroxycorticosteroid values on the same urines obtained from monkeys during a chair restraint experience (r = 0.97). Also for comparison pruposes these same urines were assayed for free THF, total cortisol, and free cortisol. The free (unconjugated) steroids showed the greatest percentage increase over basal levels

  14. Radioimmunoassay for biopterin

    International Nuclear Information System (INIS)

    Nagatsu, Toshiharu; Yamaguchi, Tokio; Kato, Takeshi; Sugimoto, Takashi; Matsuura, Sadao.

    1979-01-01

    Specific antibodies against biopterin, neopterin, and 6,7-dimethylpterin were prepared and a new type of radioimmunoassay, to which these pterins were subjected was developed. This new type of radioimmunoassay was used to determine biopterin in human urine. Specific antiserum against biopterin did not crossreact significantly with tetrahydro-biopterin, dihydro-biopterin, neopterin, 6,7-dimethylpterin, pterin, or folic acid and showed 30% binding of biopterinyl-caproyl- ( 125 I ) tyramide at a dilution of 1:800. The antisera against neopterin and dimethylpterin also showed a high specificity and did not cross-react significantly with the other pterins. The sensitivity of the radioimmunoassay was increased about ten-fold by pre-incubating the antiserum with 6,7-dimethylpterinyl-caproyl to remove antibodies against the caproic acid moiety of the biopterin conjugate. The recovery of biopterin or tetrahydro-biopterin added human urine was nearly 100% according to this type of radioimmunoassay, and the biopterin concentrations in the urine that were obtained by means of this type of radioimmunoassay showed a fairly good agreement with the values obtained by means of bioassay. The biopterin contents per milliliter of human urine showed considerable variations depending on the subjects, but those per milligram of creatinine were found to be fairly constant in normal subjects. Therefore, biopterin concentrations per milligram of creatinine in human urine may be a good indicator of biopterin metabolism in clinical chemistry. This new type of radioimmunoassay is simple, highly specific, and reproducible. Therefore, it may be very useful for the screening of atypical phenylketonuria due to biopterin deficiency and also for the study of the pathogenesis of various biopterin metabolic diseases. (J.P.N.)

  15. Radioimmunoassay for biopterin

    Energy Technology Data Exchange (ETDEWEB)

    Nagatsu, T; Yamaguchi, T; Kato, T [Tokyo Inst. of Tech. (Japan); Sugimoto, T; Matsuura, S

    1979-06-01

    Specific antibodies against biopterin, neopterin, and 6,7-dimethylpterin were prepared and a new type of radioimmunoassay, to which these pterins were subjected was developed. This new type of radioimmunoassay was used to determine biopterin in human urine. Specific antiserum against biopterin did not crossreact significantly with tetrahydro-biopterin, dihydro-biopterin, neopterin, 6,7-dimethylpterin, pterin, or folic acid and showed 30% binding of biopterinyl-caproyl- ( /sup 125/I ) tyramide at a dilution of 1:800. The antisera against neopterin and dimethylpterin also showed a high specificity and did not cross-react significantly with the other pterins. The sensitivity of the radioimmunoassay was increased about ten-fold by pre-incubating the antiserum with 6,7-dimethylpterinyl-caproyl to remove antibodies against the caproic acid moiety of the biopterin conjugate. The recovery of biopterin or tetrahydro-biopterin added human urine was nearly 100% according to this type of radioimmunoassay, and the biopterin concentrations in the urine that were obtained by means of this type of radioimmunoassay showed a fairly good agreement with the values obtained by means of bioassay. The biopterin contents per milliliter of human urine showed considerable variations depending on the subjects, but those per milligram of creatinine were found to be fairly constant in normal subjects. Therefore, biopterin concentrations per milligram of creatinine in human urine may be a good indicator of biopterin metabolism in clinical chemistry. This new type of radioimmunoassay is simple, highly specific, and reproducible. Therefore, it may be very useful for the screening of atypical phenylketonuria due to biopterin deficiency and also for the study of the pathogenesis of various biopterin metabolic diseases.

  16. Monolithic graphene fibers for solid-phase microextraction.

    Science.gov (United States)

    Fan, Jing; Dong, Zelin; Qi, Meiling; Fu, Ruonong; Qu, Liangti

    2013-12-13

    Monolithic graphene fibers for solid-phase microextraction (SPME) were fabricated through a dimensionally confined hydrothermal strategy and their extraction performance was evaluated. For the fiber fabrication, a glass pipeline was innovatively used as a hydrothermal reactor instead of a Teflon-lined autoclave. Compared with conventional methods for SPME fibers, the proposed strategy can fabricate a uniform graphene fiber as long as several meters or more at a time. Coupled to capillary gas chromatography (GC), the monolithic graphene fibers in a direct-immersion (DI) mode achieved higher extraction efficiencies for aromatics than those for n-alkanes, especially for polycyclic aromatic hydrocarbons (PAHs), thanks to π-π stacking interaction and hydrophobic effect. Additionally, the fibers exhibited excellent durability and can be repetitively used more than 160 times without significant loss of extraction performance. As a result, an optimum extraction condition of 40°C for 50min with 20% NaCl (w/w) was finally used for SPME of PAHs in aqueous samples. For the determination of PAHs in water samples, the proposed DI-SPME-GC method exhibited linear range of 0.05-200μg/L, limits of detection (LOD) of 4.0-50ng/L, relative standard deviation (RSD) less than 9.4% and 12.1% for one fiber and different fibers, respectively, and recoveries of 78.9-115.9%. The proposed method can be used for analysis of PAHs in environmental water samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. A solid phase radio immunoassay on hydrophobic membrane filters: detection of antibodies to gonocal surface antigens

    International Nuclear Information System (INIS)

    Lambden, P.R.; Watt, P.J.

    1978-01-01

    A solid phase radioimmunoassay (SPRIA) has been developed for detection of IgG antibodies to gonococcal outer membrane components. Gonococcal antigens was immobilised on a solid support by covalent coupling to CNBr-activated Sepharose in the presence of the detergent Triton X-100. Binding of specific antibody to the Sepharose-antigen complex was detected using radiolabelled Protein A as the antiglobulin. Protein A was labelled by radioacetylation with tritiated acetic anhydride, yielding a product of high specific activity and high stability. No detectable loss of activity was observed over a ten month period. The entire assay was performed on Mitex teflon hydrophobic membrane filters which held the Sepharose beads and aqueous supernatant as a discrete drop of liquid. The supernatants and incubation were easily and rapidly removed from the beads by suction on a specially-designed manifold system. This procedure removed the need for repeated and time-consuming centrifugations. Titres were obtained graphically from double log plots of cpm bound versus antiserum dilution by extrapolation of the straight line to a point corresponding to twice the control level of radioactivity binding. The assay proved to be a very reliable and simple procedure for the detection of IgG antibodies to gonococcal surface antigens. (Auth.)

  18. ''reverse'' solid-phase radioimmunoasssay for IgM-antibodies to hepatitis A virus

    Energy Technology Data Exchange (ETDEWEB)

    Meurman, O H; Matter, L; Krishna, R V; Krech, U H [Institute of Medical Microbiology, St. Gallen, Switzerland

    1981-01-01

    A ''reverse'' solid-phase radio-immuno-assay for IgM antibodies to hepatitis A virus (HAV) was developed. Anti-human IgM immunoglobulins were bound on the wells of polyvinylchloride microtiter plates. Serum specimens were incubated in the anti-human IgM coated wells and bound IgM antibodies were then assayed for antigen specificity by subsequent incubations with HAV antigen and /sup 125/I-labelled human anti-HAV IgG. The test showed a high sensitivity and specificity for anti-HAV IgM antibodies. No false-positive reactions were observed either in the sera from patients with hepatobiliary disorders other than HAV infection or in the sera containing both rheumatoid factor and anti-HAV IgG antibodies. In acute HAV infections specific IgM antibodies were present already in the first specimens taken within a few days after the onset of jaundice. The persistence of the IgM antibodies was from 4 to 6 months. IgM antibody titers up to 1,000,000 were observed in the acute phase of HAV infection. In routine diagnostic work the titration of the sera was not necessary, since a reliable qualitative result was obtained by testing the sera in a single dilution of 1:100. A similar reverse immuno-assay principle may be adaptable for the diagnostic determination of IgM antibodies to different viral and microbial antigens.

  19. Solid-phase oligosaccharide and glycopeptide synthesis using glycosynthases

    DEFF Research Database (Denmark)

    Tolborg, Jakob Fjord; Petersen, Lars; Jensen, Knud Jørgen

    2002-01-01

    and the prospect of automatability. Here, we report the first application of glycosynthases to solid-phase oligosaccharide synthesis by use of the 51 kDa serine and glycine mutants of Agrobacterium sp. beta-glucosidase, Abg E358S and E358G. Acceptors were linked to PEGA resin through a backbone amide linker (BAL...

  20. Zirconium determination in rocks by solid-phase spectrophotometry

    International Nuclear Information System (INIS)

    Brykina, G.D.; Lebedeva, G.G.; Agapova, G.F.; AN SSSR, Moscow

    1990-01-01

    A method was developed for determination of zirconium in rocks by solid-phase spectrophotometry using AV-17x8-Cl anion exchanger modified with xylenol orange. Relative standard deviation at the level of (2-4.9)x10 -3 % ZrO 2 was about 0.245

  1. Solid Phase Characterization of Tank 241-C-105 Grab Samples

    International Nuclear Information System (INIS)

    Ely, T. M.; LaMothe, M. E.; Lachut, J. S.

    2016-01-01

    The solid phase characterization (SPC) of three grab samples from single-shell Tank 241-C-105 (C-105) that were received at the laboratory the week of October 26, 2015, has been completed. The three samples were received and broken down in the 11A hot cells.

  2. Solid-phase microextraction for the analysis of biological samples

    NARCIS (Netherlands)

    Theodoridis, G; Koster, EHM; de Jong, GJ

    2000-01-01

    Solid-phase microextraction (SPME) has been introduced for the extraction of organic compounds from environmental samples. This relatively new extraction technique has now also gained a lot of interest in a broad field of analysis including food, biological and pharmaceutical samples. SPME has a

  3. N-Acyliminium Intermediates in Solid-Phase Synthesis

    DEFF Research Database (Denmark)

    Quement, Sebastian Thordal le; Petersen, Rico; Meldal, M.

    2010-01-01

    N-Acyliminium ions are powerful intermediates in synthetic organic chemistry. Examples of their use are numerous in solution-phase synthesis, but there are unmerited few reports on these highly reactive electrophiles in solid-phase synthesis. The present review covers the literature to date and i...

  4. Development of headspace solid-phase microextraction method for ...

    African Journals Online (AJOL)

    A headspace solid-phase microextraction (HS-SPME) method was developed as a preliminary investigation using univariate approach for the analysis of 14 multiclass pesticide residues in fruits and vegetable samples. The gas chromatography mass spectrometry parameters (desorption temperature and time, column flow ...

  5. Solid-phase synthesis of 3-amino-2-pyrazolines

    DEFF Research Database (Denmark)

    Nielsen, John

    1998-01-01

    The development of a solid-phase synthesis of 3-amino-2-pyrazolines is described. Conjugate addition of hydrazines to alpha,beta-unsaturated nitriles followed by cyclization yields 3-amino-2-pyrazolines. Acylation or sulfonation of the free amino-group yields a 24 member library of 3-amino-2...

  6. Investigation of binary solid phases by calorimetry and kinetic modelling

    NARCIS (Netherlands)

    Matovic, M.

    2007-01-01

    The traditional methods for the determination of liquid-solid phase diagrams are based on the assumption that the overall equilibrium is established between the phases. However, the result of the crystallization of a liquid mixture will typically be a non-equilibrium or metastable state of the

  7. Copper welding in solid phase; Svarka medi v tverdoj faze

    Energy Technology Data Exchange (ETDEWEB)

    Avagyan, V Sh

    1993-12-31

    An analysis of the publications on the technology of diffusion welding of copper in solid phase is carried out. The aspects of diffusion welding of copper with silver, aluminium, nickels, chromium, titanium, stainless steel and refractory metals are considered 35 refs.

  8. Solid-Phase Extraction Combined with High Performance Liquid ...

    African Journals Online (AJOL)

    Methods: Solid-phase extraction method was employed for the extraction of the estrogen from milk and high performance liquid chromatography-diode array detector (HPLC-DAD) was used for the determination of estrogen. Results: Optimal chromatographic conditions were achieved on an Eclipse XDB-C18 column at a ...

  9. Radioimmunoassay of pancreatic glucagon

    International Nuclear Information System (INIS)

    Nooijen, W.J.

    1979-01-01

    The author presents some of the problems and concepts related to the development of a radioimmunoassay of pancreatic glucagon. A specific derivatization of glucagon for raising specific anti-glucagon antisera is introduced, and special procedures for diminishing the non-specific effect are outlined. (G.T.H.)

  10. Erythropoietin radioimmunoassay studies

    International Nuclear Information System (INIS)

    Garcia, J.F.

    1982-01-01

    A highly sensitive radioimmunoassay capable of measuring erythropoietin concentrations in very small amounts of serum as been developed. After establishing normal human values on a large series of serum samples, serum samples from patients with polycythemia vera and patients with secondary polycythemia were obtained and the erythropoietin concentrations measured

  11. A new solid phase enzyme immuno assay using a monoclonal antibody for CEA determinations in patients with various carcinomas

    International Nuclear Information System (INIS)

    Staab, H.J.; Glock, S.; Hornung, A.

    1982-01-01

    The clinical validity of carcinoembryonic antigen (CEA) determination with a new solid phase enzyme immuno assay using a monoclonal antibody (EIA-m) in comparison with a common CEA radioimmunoassay with polyclonal antisera (RIA) was investigated for primary diagnosis in 123 patients with various malignancies and in the postoperative followup of 83 patients with gastrointestinal cancers over a period of about one year. The normal range of the new CEA test in which CEA was directly measured without any further extraction, was calculated from the CEA distribution of 147 healthy blood donors and found to be 0-1.5 μg CEA/l. Besides a very fine reproducibility the CEA-m exhibited a pronounced specificity for CEA from patients with colorectal cancers compared with the RIA. Using a cut-off level of >=1.5 μg CEA/l serum with the EIA-m, the test gave a specificity of 76% with a sensitivity of 72% for preoperative serum specimen of 82 patients with colorectal cancers and a control group of 53 patients with nonmalignant gastrointestinal diseases. In this groups of patients the EIA-m was superior to the RIA test which had a sensitivity of 75% at a specificity of 62% using a threshold of >=2.0 μg CEA/l serum. In the followup studies 3 basic tendencies of the CEA time courses well distinguished from each other could be established for both CEA-Tests. Tumor progression, characterized by steadily increasing CEA levels were evident in 20/23 cases with recurrent disease while decreasing or essentially unchanged CEA levels correlated with NED status in the patients. Furthermore 3/23 cases with metastasis in the followup had initial CEA increases indicated by EIA-m, 3-5 months before this increase of the CEA values was evident with the RIA. Transient CEA elevations, not associated with malignant growth, were found less frequently with the new EIA-m compared to the RIA. (orig.) [de

  12. Studies in Solid Phase Peptide Synthesis: A Personal Perspective

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, A R

    2007-06-01

    By the early 1970s it had became apparent that the solid phase synthesis of ribonuclease A could not be generalized. Consequently, virtually every aspect of solid phase peptide synthesis (SPPS) was reexamined and improved during the decade of the 1970s. The sensitive detection and elimination of possible side reactions (amino acid insertion, N{sup {alpha}}-trifluoroacetylation, N{sup {alpha}{var_epsilon}}-alkylation) was examined. The quantitation of coupling efficiency in SPPS as a function of chain length was studied. A new and improved support for SPPS, the 'PAM-resin', was prepared and evaluated. These and many other studies from the Merrifield laboratory and elsewhere increased the general acceptance of SPPS leading to the 1984 Nobel Prize in Chemistry for Bruce Merrifield.

  13. Semi-automated microwave assisted solid-phase peptide synthesis

    DEFF Research Database (Denmark)

    Pedersen, Søren Ljungberg

    with microwaves for SPPS has gained in popularity as it for many syntheses has provided significant improvement in terms of speed, purity, and yields, maybe especially in the synthesis of long and "difficult" peptides. Thus, precise microwave heating has emerged as one new parameter for SPPS, in addition...... to coupling reagents, resins, solvents etc. We have previously reported on microwave heating to promote a range of solid-phase reactions in SPPS. Here we present a new, flexible semi-automated instrument for the application of precise microwave heating in solid-phase synthesis. It combines a slightly modified...... Biotage Initiator microwave instrument, which is available in many laboratories, with a modified semi-automated peptide synthesizer from MultiSynTech. A custom-made reaction vessel is placed permanently in the microwave oven, thus the reactor does not have to be moved between steps. Mixing is achieved...

  14. Binding of properdin to solid-phase immune complexes

    DEFF Research Database (Denmark)

    Junker, A; Baatrup, G; Svehag, S E

    1998-01-01

    The capacity of serum to support deposition of C3, properdin and factor B was studied by enzyme-linked immunosorbent assay using solid-phase immune complexes (IC) for activation of complement. Deposition of C3 and properdin occurred in fairly dilute normal human serum (NHS), but factor B uptake...... fixed to IC was the principal ligand for properdin in the assay. The findings could have biological implications relating to complement-mediated modification of immune complexes in disease....

  15. Investigation of binary solid phases by calorimetry and kinetic modelling

    OpenAIRE

    Matovic, M.

    2007-01-01

    The traditional methods for the determination of liquid-solid phase diagrams are based on the assumption that the overall equilibrium is established between the phases. However, the result of the crystallization of a liquid mixture will typically be a non-equilibrium or metastable state of the solid. For a proper description of the crystallization process the equilibrium approach is insufficient and a kinetic approach is actually required. In this work, we show that during slow crystallizatio...

  16. Chromatography, solid-phase extraction, and capillary electrochromatography with MIPs.

    Science.gov (United States)

    Tóth, Blanka; Horvai, George

    2012-01-01

    Most analytical applications of molecularly imprinted polymers are based on their selective adsorption properties towards the template or its analogs. In chromatography, solid phase extraction and electrochromatography this adsorption is a dynamic process. The dynamic process combined with the nonlinear adsorption isotherm of the polymers and other factors results in complications which have limited the success of imprinted polymers. This chapter explains these problems and shows many examples of successful applications overcoming or avoiding the problems.

  17. Solid-phase synthesis of molecularly imprinted nanoparticles.

    Science.gov (United States)

    Canfarotta, Francesco; Poma, Alessandro; Guerreiro, Antonio; Piletsky, Sergey

    2016-03-01

    Molecularly imprinted polymers (MIPs) are synthetic materials, generally based on acrylic or methacrylic monomers, that are polymerized in the presence of a specific target molecule called the 'template' and capable of rebinding selectively to this target molecule. They have the potential to be low-cost and robust alternatives to biomolecules such as antibodies and receptors. When prepared by traditional synthetic methods (i.e., with free template in solution), their usefulness has been limited by high binding site heterogeneity, the presence of residual template and the fact that the production methods are complex and difficult to standardize. To overcome some of these limitations, we developed a method for the synthesis of MIP nanoparticles (nanoMIPs) using an innovative solid-phase approach, which relies on the covalent immobilization of the template molecules onto the surface of a solid support (glass beads). The obtained nanoMIPs are virtually free of template and demonstrate high affinity for the target molecule (e.g., melamine and trypsin in our published work). Because of an affinity separation step performed on the solid phase after polymerization, poor binders and unproductive polymer are removed, so the final product has more uniform binding characteristics. The overall protocol, starting from the immobilization of the template onto the solid phase and including the purification and characterization of the nanoparticles, takes up to 1 week.

  18. Silica Modified with Polyaniline as a Potential Sorbent for Matrix Solid Phase Dispersion (MSPD) and Dispersive Solid Phase Extraction (d-SPE) of Plant Samples

    Science.gov (United States)

    Sowa, Ireneusz; Wójciak-Kosior, Magdalena; Strzemski, Maciej; Sawicki, Jan; Staniak, Michał; Dresler, Sławomir; Szwerc, Wojciech; Mołdoch, Jarosław; Latalski, Michał

    2018-01-01

    Polyaniline (PANI) is one of the best known conductive polymers with multiple applications. Recently, it was also used in separation techniques, mostly as a component of composites for solid-phase microextraction (SPME). In the present paper, sorbent obtained by in situ polymerization of aniline directly on silica gel particles (Si-PANI) was used for dispersive solid phase extraction (d-SPE) and matrix solid–phase extraction (MSPD). The efficiency of both techniques was evaluated with the use of high performance liquid chromatography with diode array detection (HPLC-DAD) quantitative analysis. The quality of the sorbent was verified by Raman spectroscopy and microscopy combined with automated procedure using computer image analysis. For extraction experiments, triterpenes were chosen as model compounds. The optimal conditions were as follows: protonated Si-PANI impregnated with water, 160/1 sorbent/analyte ratio, 3 min of extraction time, 4 min of desorption time and methanolic solution of ammonia for elution of analytes. The proposed procedure was successfully used for pretreatment of plant samples. PMID:29565297

  19. Silica Modified with Polyaniline as a Potential Sorbent for Matrix Solid Phase Dispersion (MSPD and Dispersive Solid Phase Extraction (d-SPE of Plant Samples

    Directory of Open Access Journals (Sweden)

    Ireneusz Sowa

    2018-03-01

    Full Text Available Polyaniline (PANI is one of the best known conductive polymers with multiple applications. Recently, it was also used in separation techniques, mostly as a component of composites for solid-phase microextraction (SPME. In the present paper, sorbent obtained by in situ polymerization of aniline directly on silica gel particles (Si-PANI was used for dispersive solid phase extraction (d-SPE and matrix solid–phase extraction (MSPD. The efficiency of both techniques was evaluated with the use of high performance liquid chromatography with diode array detection (HPLC-DAD quantitative analysis. The quality of the sorbent was verified by Raman spectroscopy and microscopy combined with automated procedure using computer image analysis. For extraction experiments, triterpenes were chosen as model compounds. The optimal conditions were as follows: protonated Si-PANI impregnated with water, 160/1 sorbent/analyte ratio, 3 min of extraction time, 4 min of desorption time and methanolic solution of ammonia for elution of analytes. The proposed procedure was successfully used for pretreatment of plant samples.

  20. Determination of total bile acids in serum. A comparison of a radioimmunoassay with an enzymatic-fluorimetric method

    International Nuclear Information System (INIS)

    Starkey, B.J.; Marks, V.

    1982-01-01

    A solid phase radioimmunoassay kit method for total conjugated bile acids has been compared to an enzymatic fluorimetric method for total serum bile acids. The methods were compared with respect to: precision, cross-reactivity (molar equivalence) of different bile salts, recovery of different bile salts from serum, the reference range for a healthy population, linearity, coefficient of correlation, diagnostic effectiveness, cost and ease of assay. Both assays seemed equally capable of predicting the presence or absence of liver disease. Radioimmunoassay had little advantage over the enzymatic-fluorimetric method. Its relative ease was far outweighed by its greater cost and poorer analytical performance. (Auth.)

  1. The study of long-term stability in liquid-solid phases for HLW disposal

    International Nuclear Information System (INIS)

    Wei, Y.Y.; Tseng, C.L.; Yang, J.Y.; Ke, C.H.; Wang, T.H.; Jan, Y.L.; Lee, C.B.; Lan, P.L.; Hsu, C.N.; Tsai, S.C.; Li, M.H.; Teng, S.P.

    2005-01-01

    Full text of publication follows: This study is conducted to observe changes in both chemical properties of buffer materials and liquid phases over an experimental period of 2 years. In our experiments, bentonite powder and crushed granite are separately mixed with synthetic groundwater, synthetic seawater and de-ionised water at a fixed liquid-solid ratio of 30. A mixed set with both bentonite and granite together as solid phase is also investigated. During this study, aliquots of the liquid phases are sampled every two months and pH and Eh values are measured immediately. Concentrations of Na, Mg, K, Al, Ca, Ti, Mn, Ba, Fe, Sr, Li and Th are analyzed in the liquid phase directly by ICP-AES. After separation by centrifugation followed by freeze drying and digestion, the solid phases are analyzed as well for elemental composition. Alteration of solid phases during the experimental period is discussed. The preliminary results show that the pH values of the three solutions vary considerably in the individual experimental systems containing bentonite, granite or the mixed system. In general, higher pH values are found in DI-water for all solid phases. Eh values fluctuate a lot in the range 100 to 300 mV in all experiment sets. Different to the experiments with granite for which similar Eh values are found in all solutions, a significantly different Eh-value is found in the experiment with bentonite in DI-water as compared to the other solutions. The results from element analysis indicate that equilibrium is achieved after only two months and element concentrations change only slightly thereafter. We conclude from our experiments that both bentonite and granite keep their characteristics as radionuclide sorbents in the vicinity of a nuclear waste repository. Reaction equilibria appear to be attained rapidly. Because there are just a few alterations in this study, it would be a huge error source in analyzing from the inhomogeneous solid phase such as granite and losses

  2. Radioimmunoassay in endocpinology

    International Nuclear Information System (INIS)

    Ametov, A.S.; Torjtsina, L.K.

    1983-01-01

    Radioimmunoassay of the level of various hormones in blood for the diagnosis of thyroid gland diseases, diabetes mellitus, pancreatic gland diseases, adrenal cortex, phophorous-calcium exchange, cerebral-hypophysial deseases, peripheric endocrine glands diseases and others are considered. It is shown that CEA methods implantation in clinical practice permits to obtain a number of new data on mechanism of neurohumoral interrelations of various organs and organism systems

  3. Automation systems for radioimmunoassay

    International Nuclear Information System (INIS)

    Yamasaki, Paul

    1974-01-01

    The application of automation systems for radioimmunoassay (RIA) was discussed. Automated systems could be useful in the second step, of the four basic processes in the course of RIA, i.e., preparation of sample for reaction. There were two types of instrumentation, a semi-automatic pipete, and a fully automated pipete station, both providing for fast and accurate dispensing of the reagent or for the diluting of sample with reagent. Illustrations of the instruments were shown. (Mukohata, S.)

  4. Chemical Kinetics of Progesterone Radioimmunoassay System

    International Nuclear Information System (INIS)

    Abdel-Fattah, A.A.; Moustsfs, K.A.; El-Kolally, M.T.

    2004-01-01

    Progesterone is one of the steroids secreted by the corpus Iuteum in females during the menstrual cycle, and in a much higher amount by the placenta during pregnancy. It is also secreted in a minor quantities by the adrenal cortex in both males and females. Measurement of serum progesterone represents one of diagnostic values in menstrual disorders and infertility. The progesterone radioimmunoassay is based on the competition between unlabelled progesterone and a fixed quantity of 125 I-labeled progesterone for a limited number of binding sites on progesterone specific antibody. Allowing for a fixed amount of magnetizable immunosorbent to react, the antigen-antibody complex is bound on solid particles which are then separated by magnetic rack, and the radioactivity of the solid phase was counted using gamma counter. In this work, the chemical kinetics of the assay was followed, where the specific rate constant (K) was calculated at 4 degree and 37 degree and the activation energy (E act ) were calculated and the reaction rate was deduced

  5. Comparative study of radioimmunoassay dates

    International Nuclear Information System (INIS)

    Venegas Sanchez, Ruth.

    1986-01-01

    The radioimmunoassay is frequently used in clinical chemistry for the concentration determination of several substances like hormones as thyrotropine and thyroxine. In this experiment the dates of tyroxine radioimmunoassay are processed by three methods: a) like the recommendation of the IAEA, b) Dr. G. Chase method, c) according to the provider. The best method was Dr. Chase's. (author)

  6. Solid-phase vibrational redox reactions in coordinated oxides

    International Nuclear Information System (INIS)

    Kostikova, G.P.; Korol'kov, D.V.; Kostikov, Yu.P.

    1996-01-01

    The properties of multicomponent oxides (YBa 2 Cu 3 O 7-x , etc.), incorporating different valency forms of each of two (or more) different elements have been compared with the properties of the known chemical systems, where vibrational (periodic) redox-reactions are realized a fortiori. The essence of the new theoretical concept suggested consists in the following: high-T c superconductivity of the complex oxides and similar compounds originates from vibrational redox reaction proceeding in solid phase and involving different valency atoms of every element

  7. Solid phase micro-extraction in environmental atmosphere

    International Nuclear Information System (INIS)

    Tao Ping; Wei Lifan; Tan Yun

    2002-01-01

    Solid phase micro-extraction (SPME) is an advanced technique of sample pretreatment in environmental atmosphere analysis, i.e., a sampling method of extracting volatile organic compounds from environmental gas. According to the primary survey on the theory and application of SPME, a suitable extraction tip, i.e., a coated fused silica fiber, is selected to construct a SPME apparatus. This SPME apparatus is used to extract volatile organic compounds from environmental atmosphere and a qualitative detection is conducted in gas chromatography-mass spectrometer system. Good experimental results are obtained

  8. Solid-Phase S-Alkylation Promoted by Molecular Sieves.

    Science.gov (United States)

    Calce, Enrica; Leone, Marilisa; Mercurio, Flavia Anna; Monfregola, Luca; De Luca, Stefania

    2015-11-20

    A solid-phase S-alkylation procedure to introduce chemical modification on the cysteine sulfhydryl group of a peptidyl resin is reported. The reaction is promoted by activated molecular sieves and consists of a solid-solid process, since both the catalyst and the substrate are in a solid state. The procedure was revealed to be efficient and versatile, particularly when used in combination with the solution S-alkylation approach, allowing for the introduction of different molecular diversities on the same peptide molecule.

  9. Wax Precipitation Modeled with Many Mixed Solid Phases

    DEFF Research Database (Denmark)

    Heidemann, Robert A.; Madsen, Jesper; Stenby, Erling Halfdan

    2005-01-01

    The behavior of the Coutinho UNIQUAC model for solid wax phases has been examined. The model can produce as many mixed solid phases as the number of waxy components. In binary mixtures, the solid rich in the lighter component contains little of the heavier component but the second phase shows sub......-temperature and low-temperature forms, are pure. Model calculations compare well with the data of Pauly et al. for C18 to C30 waxes precipitating from n-decane solutions. (C) 2004 American Institute of Chemical Engineers....

  10. Sensitive and fast mutation detection by solid phase chemical cleavage

    DEFF Research Database (Denmark)

    Hansen, Lise Lotte; Justesen, Just; Kruse, Torben A

    1996-01-01

    We have developed a solid phase chemical cleavage method (SpCCM) for screening large DNA fragments for mutations. All reactions can be carried out in microtiterwells from the first amplification of the patient (or test) DNA through the search for mutations. The reaction time is significantly...... reduced compared to the conventional chemical cleavage method (CCM), and even by using a uniformly labelled probe, the exact position and nature of the mutation can be revealed. The SpCCM is suitable for automatization using a workstation to carry out the reactions and a fluorescent detection-based DNA...

  11. Automation of radioimmunoassay

    International Nuclear Information System (INIS)

    Yamaguchi, Chisato; Yamada, Hideo; Iio, Masahiro

    1974-01-01

    Automation systems for measuring Australian antigen by radioimmunoassay under development were discussed. Samples were processed as follows: blood serum being dispensed by automated sampler to the test tube, and then incubated under controlled time and temperature; first counting being omitted; labelled antibody being dispensed to the serum after washing; samples being incubated and then centrifuged; radioactivities in the precipitate being counted by auto-well counter; measurements being tabulated by automated typewriter. Not only well-type counter but also position counter was studied. (Kanao, N.)

  12. Radioimmunoassay in microtiter plates

    International Nuclear Information System (INIS)

    Hirschberg, T.; Hirschberg, H.

    1987-01-01

    A radioimmunoassay was performed in the wells of casein-coated microplates employing 125 I-labelled sheep anti-human second antibody. The antigen-antibody complexes were thereafter dislodged from the well walls using detergent sodium dodecyl sulfate (SDS) and the entire contents of the wells were simultaneously absorbed into 48 cellulose acetate-absorbing cartridges. All 48 cartridges were transferred to counting vials and the radioactivity determined by standard gamma counting techniques. The particular advantage of the method described here is the ease with which the supernatants can be collected and transferred to counting vials with minimal handling of radioactive samples. 6 refs.; 1 figure; 1 table

  13. Radioimmunoassay of plasma progesterone

    Energy Technology Data Exchange (ETDEWEB)

    Langer, L; Veleminsky, J [Institute of Clinical Endocrinology, Lubochna (Czechoslovakia); Hampl, R; Starka, L [Vyzkumny Ustav Endokrinologicky, Prague (Czechoslovakia); Holan, J [Comenius Univ., School of Medicine, Martin (Czechoslovakia). Dept. of Physics and Nuclear Medicine

    1978-06-30

    A simple modification of plasma progesterone radioimmunoassay is described. 11..cap alpha..-Hydroxyprogesterone hemisuccinate - BSA conjugate was used as an immunogen. (1,2,6,7-H-3) Progesterone specific radioactivity 82 Ci.mmol/sup -1/ was purchased from Radiochemical Centre Amersham (England). The method has been applied for the analysis of more than 2000 plasma samples. The typical fluctuation of progesterone in plasma during the menstrual cycle, using data obtained with this method is illustrated. The reliability criteria of the method are given.

  14. Radioimmunoassay for Melatonin

    International Nuclear Information System (INIS)

    Tapp, E.; Skinner, R.G.; Phillips, V.

    1980-01-01

    A radioimmunoassay for melatonin has been developed and used to measure the level of melatonin of male and post-menopausal female patients coming to operation for benign and malignant conditions. The amount of melatonin in the serum of the females was considerably lower than that in males. No difference could be found between patients suffering from benign and malignant conditions. A patient with a non-parenchymatous pineal tumour had considerably lower levels in the serum at three months after surgery and radiotherapy. A further month later melatonin could not be found in samples of serum taken over a 24-hour period. (author)

  15. Anamnesis of the radioimmunoassay: A historical reminiscence

    Energy Technology Data Exchange (ETDEWEB)

    Kallee, E

    1984-01-27

    Anamnesis of the Radioimmunoassay - A Historical Reminiscence: Several requirements have to be met before the first radioimmunoassay of a proteohormone (i.e., insulin) could be developed. One of these requirements was that iodination ought not substantially impair the immunologic properties of the insulin molecule. Since the reversibility of antigen adsorption to antibodies is the most important basis of all immunoassays, the adsorptive behavior of proteins first had to be studied at extremely low protein concentrations. Only after these requirements had been investigated was direct electrophoretic detection of a nonprecipitating anti-hormone antibody possible by desorption of insulin on filter paper. Later, the inaccuracy of the species specificity of insulin-binding antibodies proved to be particularly useful for the determination of insulin in human sera.

  16. Solid phase crystallisation of HfO2 thin films

    International Nuclear Information System (INIS)

    Modreanu, M.; Sancho-Parramon, J.; O'Connell, D.; Justice, J.; Durand, O.; Servet, B.

    2005-01-01

    In this paper, we report on the solid phase crystallisation of carbon-free HfO 2 thin films deposited by plasma ion assisted deposition (PIAD). After deposition, the HfO 2 films were annealed in N 2 ambient for 3 h at 350, 550 and 750 deg. C. Several characterisation techniques including X-ray reflectometry (XRR), X-ray diffraction (XRD), spectroscopic ellipsometry (SE) and atomic force microscopy (AFM) were used for the physical characterisation of as-deposited and annealed HfO 2 . XRD has revealed that the as-deposited HfO 2 film is in an amorphous-like state with only traces of crystalline phase and that the annealed films are in a highly crystalline state. These results are in good agreement with the SE results showing an increase of refractive index by increasing the annealing temperature. XRR results show a significant density gradient over the as-deposited film thickness, which is characteristic of the PIAD method. The AFM measurements show that the HfO 2 layers have a smooth surface even after annealing at 750 deg. C. The present study demonstrates that the solid phase crystallisation of HfO 2 PIAD thin films starts at a temperature as low as 550 deg. C

  17. Preparation and evaluation of primary reagents for the radioimmunoassay of prolactin hormone as a diagnostic marker for some clinical applications

    International Nuclear Information System (INIS)

    Ebeid, N.H.A.

    2010-01-01

    The preparation of high technology radioimmunoassay (RIA) reagents with low cost is considered to be one of the main objectives of the present study. This may be extremely helpful in diagnosis and treatment of disorders of the anterior pituitary gland or the hypothalamus portion of the brain. The local prolactin (PRL) liquid-phase and solid-phase RIA systems were prepared for the invitro assessment of human prolactin in human serum i.e., (hyperprolactinemia, can occur as a result of pituitary adenomas and hypoprolactinemia are observed in cases of hypopituitarism).The objectives of the present work were designed to achieve: -The production of PRL polyclonal antibodies , PRL standards and radiolabeled PRL tracers. - Optimization of local radioimmunoassay methods (liquid phase - double antibody and solid phase - cellulose particles). - Validation studies of the local assay were carried out using the performance characteristics of the succeeded immunoassays. In the present study, liquid phase and solid phase RIA systems for measurement of PRL proved to be specific, sensitive, precise and accurate. This may suggest that, the liquid and solid phase RIA techniques should be suited for routine laboratory use and have been used effectively in the diagnosis and treatment of patient with pituitary dysfunctions and possible reproductive disability.

  18. Radioimmunoassay of steroid hormone

    International Nuclear Information System (INIS)

    Murakami, Tadashi

    1975-01-01

    Low acid pepsin treated gamma-globulin was applied to ammonium sulfate salting out method, which was a method to separate bound fraction from free one in radioimmunoassay of steroid hormone, and the effect of the separation and the standard curve were examined. Pepsin treated gamma-globulin was prepared in pH 1.5 to 5.5 and then the pepsin was completely removed. It had an effect to accelerate the precipitation in radioimmunoassay of steroid hormone labelled with 3 H. The effect of pepsin treated gamma-globulin to adhere free steroid hormone and to slat out bound one was compared with that of human gamma-globulin. Pepsin treated gamma-globulin, which was water soluble, could easier reach its optimal concentration, and the separation effect was better than human gamma-globulin. The standard curve of it was steeper, particularly in a small dose, and the reproducibility was also better. It could be applied not only to aldosterone and DOC, but also to the steroid hormones, such as progesterone and DHEA, and it seemed suitable for routine measurement method. (Kanao, N.)

  19. Radioimmunoassay of oxytocin

    International Nuclear Information System (INIS)

    Dawood, M.Y.; Raghavan, K.S.; Pociask, C.

    1978-01-01

    The evaluation of a radioimmunoassay of oxytocin is described. The method involved careful collection and transportation of blood at 4 0 C, acidification of the plasma, extraction with Fuller's earth and radioimmunoassay using antisera raised in rabbits immunized against oxytocin conjugated to bovine serum albumin and 125 I-labelled oxytocin. The antisera showed insignificant cross-reaction with a variety of small peptides including vasopressin and vasotocin. The limit of detection of the assay was 2.5 pg with intra-assay and interassay coefficients of variation of 7 to 15% and 12 to 18% respectively. Seventy-seven per cent (88 out of 116) of the pregnant women tested had detect-able maternal plasma oxytocin. Serial samples of maternal plasma showed a significant increase in oxytocin from the first to the second stage of labour and a significant decrease in the third stage. Oxytocin concentrations in the umbilical arterial plasma were significantly higher in patients in labour. The significance of these findings is discussed. (author)

  20. Radioimmunoassay of platelet proteins

    International Nuclear Information System (INIS)

    Pepper, D.S.

    1987-01-01

    The radioimmunoassay of platelet-specific proteins has proven to be an excellent way of monitoring platelet activation in vivo. In contrast to earlier methods such as aggregometry, which has been the major tool used in the evaluation of antiplatelet drugs, the RIAs are capable of working with samples which have been subjected to physiological conditions such as haematocrit, oxygen tension, shear rate and ionized calcium concentration. Also, in contrast to aggregometry, no choice of agonist is necessary. Thus, for the first time it has been possible to monitor the effects of therapeutic intervention with drugs upon the platelet release reaction in vivo. It seems reasonable to equate the release reaction in vivo with activation in vivo, though the stimuli necessarily remain unknown. Nevertheless, the fact that a significant number of the compounds mentioned in Table 3 are indeed capable of reducing platelet activation in vivo and that this effect can be measured objectively is a major step forward in our understanding of platelet pharmacology. Two important goals remain to be achieved, however, the establishment of nonhuman animal models for the evaluation of newer compounds in vivo and longer-term goal of proving in the clinical setting the relevance or otherwise of platelet activation per se to the clinical outcome of a particular disease. In this respect, the availability of accurate, reliable and specific radioimmunoassays has a central role

  1. Determination of antibodies for the core antigen of the hepatitis B virus by means of a direct radioimmunoassay with /sup 32/P-marked core particles. Nachweis von Antikoerpern gegen das Core Antigen des Hepatitis B Virus durch einen direkten Radioimmunoassay mit /sup 32/P markierten Core Partikeln

    Energy Technology Data Exchange (ETDEWEB)

    Wolff, W

    1983-11-04

    After characterization of the protein kinase of the hepatitus B virus and the purification of this enzyme, the enzyme was proved to be a component of the core particle with a high affinity for ATP. Based on this a new procedure for the determination of the diagnostically important antibody for HBcAg (anti HBc) is presented, namely the direct radioimmunoassay by means of the marking of HBcAg with /sup 32/P. This procedure is much more sensitive than the traditional inhibitory test using an enzyme-marked anti-HBc immunoglobulin as a reagent (EIBA). Using this new RIA anti-HBc was shown to be present in the majority of the EIBA anti-HBc positive serums and also in a large number of EIBA anti-HBc negative serums from a population at high risk for the Hepatitis B virus. The significance of reproducible threshold values was also shown. RIA activity was seldom found in healthy blood donors without HBsAg and anti-HBs. On the other hand blood donors with increased serum transaminase values showed a significantly higher frequency of activity. This weak activity only determinable in dRIA, could be attributed to a very limited heaptitis B viral infection or to a cross-reaction. (TRV)

  2. Application of solid-phase radioimmunoassay in determining antibodies to Aujeszky's disease virus in blood serum of vaccinated pigs

    International Nuclear Information System (INIS)

    Rodak, L.; Smid, B.; Valicek, L.

    1983-01-01

    In the blood sera of pigs vaccinated with inactivated vaccines manufactured by three different manufacturers the RIA method was used to determine the specific antibodies to the virus of Aujeszky's disease. In certain groups of vaccinated pigs the results of the RIA examination are unfavourably affected by the bond of antibodies to the cellular antigenous determinants. This proves that following vaccination antibodies are formed not only against the viral antigen but also against the antigens of cells on which the vaccination virus is propagated. These shortcomings are eliminated by the use of suitable cellular cultures for the preparation of viral and control antigens. Antigens are applicable for RIA and for ELISA examinations of blood sera of infected and vaccinated pigs. The advantages are described of the RIA and ELISA methods as compared with the virus neutralization test. (author)

  3. Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    Energy Technology Data Exchange (ETDEWEB)

    Lange, W; Koehler, H; Apodaca, J [Bundesgesundheitsamt, Berlin (Germany, F.R.). Abt. fuer Virologie

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were re-examined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not encountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test.

  4. Application of solid-phase radioimmunoassay in determining antibodies to Aujeszky's disease virus in blood serum of vaccinated pigs

    Energy Technology Data Exchange (ETDEWEB)

    Rodak, L; Smid, B; Valicek, L [Vyzkumny Ustav Veterinarniho Lekarstvi, Brno-Medlanky (Czechoslovakia)

    1983-11-01

    In the blood sera of pigs vaccinated with inactivated vaccines manufactured by three different manufacturers the RIA method was used to determine the specific antibodies to the virus of Aujeszky's disease. In certain groups of vaccinated pigs the results of the RIA examination are unfavourably affected by the bond of antibodies to the cellular antigenous determinants. This proves that following vaccination antibodies are formed not only against the viral antigen but also against the antigens of cells on which the vaccination virus is propagated. These shortcomings are eliminated by the use of suitable cellular cultures for the preparation of viral and control antigens. Antigens are applicable for RIA and for ELISA examinations of blood sera of infected and vaccinated pigs. The advantages are described of the RIA and ELISA methods as compared with the virus neutralization test.

  5. The Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    International Nuclear Information System (INIS)

    Lange, W.; Koehler, H.; Apodaca, J.

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott Laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1,968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1,968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were reexamined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not ecountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test. (orig.) [de

  6. The Ausab test - a radioimmunoassay in the solid phase for the detection of antibodies against HBsAg

    International Nuclear Information System (INIS)

    Lange, W.; Koehler, H.; Apodaca, J.

    1974-01-01

    The suitability of a newly developed RIA (Ausab test, Abbott laboratories) for the detection of antibodies against the Hepatitis B (surface) antigen (HBsAg) has been tested on 1968 sera of blood donors. Reproducibility test and specificity test were included. During the examination the technique of the Ausab test was changed from the original one-step to the two-step procedure. With the one-step technique 431 of 1968 sera (21.9%) showed positive reactions. During the test problems concerning the differentiation between positive and negative results were encountered due to high unspecific binding of radioactivity. Positive sera were re-examined employing the two-step technique and only 77.4% of the previously positive reactions could be reproduced. 50 sera that were negative in the one-step test remained negative in the two-step test. Difficulties concerning nonspecific binding of radioactivity as observed with the one-step technique were not encountered with the two-step procedure. On 92 of the confirmed positive sera a specificity test was run and 90 (97.8%) proved to be specific. A calculated 16.5% of the blood donors in Berlin have to be considered as antibody carriers. Only 6 of the Ausab positive sera were found to give positive reactions in CEP. 3 sera that were initially positive in CEP could neither be confirmed in a repeated CEP nor in the Ausab test. (orig.) [de

  7. Experimental and computational studies on molecularly imprinted solid-phase extraction for gonyautoxins 2,3 from dinoflagellate Alexandrium minutum.

    Science.gov (United States)

    Lian, Ziru; Li, Hai-Bei; Wang, Jiangtao

    2016-08-01

    An innovative and effective extraction procedure based on molecularly imprinted solid-phase extraction (MISPE) was developed for the isolation of gonyautoxins 2,3 (GTX2,3) from Alexandrium minutum sample. Molecularly imprinted polymer microspheres were prepared by suspension polymerization and and were employed as sorbents for the solid-phase extraction of GTX2,3. An off-line MISPE protocol was optimized. Subsequently, the extract samples from A. minutum were analyzed. The results showed that the interference matrices in the extract were obviously cleaned up by MISPE procedures. This outcome enabled the direct extraction of GTX2,3 in A. minutum samples with extraction efficiency as high as 83 %, rather significantly, without any need for a cleanup step prior to the extraction. Furthermore, computational approach also provided direct evidences of the high selective isolation of GTX2,3 from the microalgal extracts.

  8. Human aldolase B subunit-specific radioimmunoassay

    International Nuclear Information System (INIS)

    Asaka, M.; Alpert, E.

    1983-01-01

    A radioimmunoassay was developed for the direct quantification of aldolase B in human serum and tissues. The method is a double-antibody radioimmunoassay technique using radioiodinated aldolase B homopolymer as ligand, chicken antibodies to aldolase B and rabbit antibodies to chicken IgG. This radioimmunoassay was shown to be specific for the aldolase B subunit, with no cross-reactivity with either human aldolase A subunit or homopolymeric human aldolase C (C 4 ). The lowest measurable amount by this method was 2 ng/ml. Aldolase B is predominantly found in normal liver tissue, with relatively-high aldolase B levels also observed in kidney. Aldolase B levels in the serum obtained from 11 normal subjects ranged from 23 to 38 ng/ml, with a mean of 28.5 +- 9.2 (S.D.) ng/ml. Almost all of patients with hepatitis had serum aldolase B levels greater than 30 ng/ml. In cancer patients, serum aldolase B was slightly elevated in patients with metastatic liver cancer and primary lever cell carcinoma, whereas no elevation of serum aldolase B was shown in patients without liver metastasis. (Auth.)

  9. Serum 3,3'-L-diiodothyronine, a direct radioimmunoassay in human serum: method and clinical results. [/sup 125/I tracer technique

    Energy Technology Data Exchange (ETDEWEB)

    Burger, A.; Sakoloff, C.

    1977-09-01

    A specific radioimmunoassay for 3,3'-diiodothyronine (T/sub 2/) is described which is capable of detecting as little as 1.3 ng/dl. The antiserum recognizes mainly T/sub 2/; biliary conjugates of T/sub 2/ bind slightly to the antibody. The intraassay and interassay coefficients of variation were, respectively, 5.7% and 13.1%. T/sub 2/ was detected in the serum of hypothyroid patients treated with triiodothyronine (T/sub 3/) and in euthyroid subjects treated with reverse triiodothyronine (rT/sub 3/). These results suggest that both T/sub 3/ and rT/sub 3/ are deiodinated to T/sub 2/. Serum concentrations of T/sub 2/ in normal subjects decreased with age. Between 20 and 40 years the mean concentration was 4.3 +- 2.0 ng/dl (2 SD), between 41 and 60 years it varied from 1.9 to 5.8 ng/dl (3.8 +- 0.3 ng/dl, SE) and in elderly subjects have 60 years concentrations varied from unmeasurable to 4 ng/dl (2.9 +- 0.4 ng/dl, SE). Low serum T/sub 2/ concentrations were found in anorexia nervosa (2.5 +- 0.3 ng/dl, SE). In hypothyroidism the serum concentrations were low or unmeasurable. As most of the hypothyroid subjects were elderly their serum T/sub 2/ concentrations overlapped with the low values found in the elderly euthyroid subjects. In classical hyperthyroidism serum T/sub 2/ concentrations were greatly increased (3.3 to 31 ng/dl (11.8 +- 2.7 ng/dl, SE) but in ''T/sub 3/ toxicosis'' the concentrations were only modestly increased (2.4 to 8.8 ng/dl, 5.2 +- 0.8 ng/dl, SE).

  10. Solid-Phase Synthesis of RNA Analogs Containing Phosphorodithioate Linkages.

    Science.gov (United States)

    Yang, Xianbin

    2017-09-18

    The oligoribonucleotide phosphorodithioate (PS2-RNA) modification uses two sulfur atoms to replace two non-bridging oxygen atoms at an internucleotide phosphorodiester backbone linkage. Like a natural phosphodiester RNA backbone linkage, a PS2-modified backbone linkage is achiral at phosphorus. PS2-RNAs are highly stable to nucleases and several in vitro assays have demonstrated their biological activity. For example, PS2-RNAs silenced mRNA in vitro and bound to protein targets in the form of PS2-aptamers (thioaptamers). Thus, the interest in and promise of PS2-RNAs has drawn attention to synthesizing, isolating, and characterizing these compounds. RNA-thiophosphoramidite monomers are commercially available from AM Biotechnologies and this unit describes an effective methodology for solid-phase synthesis, deprotection, and purification of RNAs having PS2 internucleotide linkages. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 John Wiley & Sons, Inc.

  11. Use of solid-phase salt catalysts in furfural preparation

    Energy Technology Data Exchange (ETDEWEB)

    Morozov, E.F.; Shkut, V.M.; Kebich, M.S.; Kuznetsova, T.A.

    1981-01-01

    The manufacture of furfural (I) from tanning waste, birch sawdust, or corncobs at 220-230 degrees in the presence of 2.0-3.0% double superphosphate, ammophos, (NH/sub 4/)/sub 2/SO/sub 4/, NH/sub 4/NO/sub 3/, or NH/sub 4/Cl was evaluated. Most of I is formed within 40 minutes in the presence of NH4NO3 or NH4Cl, and within 55 minutes in the presence of double superphosphate. The highest yield of I was obtained in the presence of NH4NO3 and/or NH4Cl. The solid-phase catalyst caused a little degradation of lignocellulose.

  12. Radioimmunoassay of anabolic steroids

    International Nuclear Information System (INIS)

    Hampl, R.; Stranska, I.; Starka, L.; Picha, J.; Chundela, B.

    1978-01-01

    Alternative antisera against 17 α-methyltestosterone and 19-nortestosterone were raised and used for radioimmunoassay of anabolic steroids. Tritiated compounds were used as radioligands. The RIA method suitable for doping control is proposed for 17 α-alkylated anabolic steroids in both plasma and urine, using qoat antiserum against methyltestosterone-3-carboxymethyloxime-BSA. Sensitivity of the method was expressed as least amount of nonradioactive methandienone which, when added to normal urine or plasma, caused statistically significant decrease of measured supernatant radioactivity at 99% level. The amounts from 50 to 500 pg were tested, each in eight parallel determinations. The amounts of 100 pg for plasma and 200 pg for urine met these criteria. The respective coefficients of variation did not depend on the amount of steroid added in this range. They averaged 4.60% for plasma and 4.95% for urine, respectively. (T.I.)

  13. Radioimmunoassay for jasmonic acid

    Energy Technology Data Exchange (ETDEWEB)

    Knoefel, H.D.; Brueckner, C.; Kramell, R.; Sembdner, G.; Schreiber, K. (Akademie der Wissenschaften der DDR, Halle/Saale. Inst. fuer Biochemie der Pflanzen)

    1984-01-01

    A radioimmunoassay (RIA) for the natural plant growth regulator jasmonic acid (JA) was developed. The antiserum was raised in rabbits against (+-)-JA linked to bovine serum albumin. As tracer tritium labelled (+-)-JA (spec. act. 7.4 x 10/sup 9/ Bq x mmol/sup -1/) was used. Cross-reactivity studies with compounds structurally related to JA demonstrated the antiserum to be specific for JA, abscisic acid normally present in the same extract does not interfer. The RIA has a detection limit of 2 ng (-)-JA methylester, a measuring range 2-200 ng, and no extensive purification is required prior to estimation. Therefore, in JA analysis the RIA described is superior to GC, HPLC, and bioassay. This new method has been employed for studies on the distribution of JA in different plant organs of the broad bean, Vicia faba L.

  14. Radioimmunoassay of synthetic steroids

    Energy Technology Data Exchange (ETDEWEB)

    Raynaud, J -P; Bucourt, R; Salmon, J

    1975-12-01

    The sensitivity of a radioimmunoassay depends on the intrinsic association constant of the interaction between ligand and antibody. Its specificity depends on the position of the chain which forms the link with the antigen. Thus, an antibody specific of estradiol has been obtained by coupling estradiol to albumin via a chain at position 7. For synthetic steroids the structure of which is sufficiency different from that of natural hormones, the requirements for a sensitive assay method not involving chromatography are simply maximum affinity and positioning of the couple at a site which does not undergo metabolic attack. These criteria were used to develop assays for R 2858 and R 2453 which obviate the need to administer radioactive product in clinical pharmacology. Cross-reaction with structural analogs may be used to assay competitors. Thus, R 2323 antibody, highly specific for endogenous steroids, may be used to assay other trienes such as R 1697 (trenbolone) and R 2010 (norgestrienone).

  15. Delta antibody radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Kselikova, M; Urbankova, J

    1985-11-15

    The principle and procedure are described of the radioimmunoassay of delta antibody (delta-Ab) using the ABBOTT ANTI-DELTA kit by Abbott Co. A description is given of the kit, the working procedure and the method of evaluation. The results are reported of the incidence of delta-Ab in sera of patients with viral hepatitis B, in haemophiliacs, carriers of the hepatitis B virus surface antigen (HBsAg) and blood donors. The presence was detected of delta-Ab in one HBsAg carrier. The necessity is emphasized of delta-Ab determinations in the blood of donors in view of the antibody transfer with blood and blood preparations.

  16. Radioimmunoassay of erythropoietin

    Energy Technology Data Exchange (ETDEWEB)

    Goldwasser, E; Sherwood, J B [Chicago Univ., IL (USA). Dept. of Biochemistry

    1981-07-01

    A brief review of the historical development of the radioimmunoassay (RIA) for serum erythropoietin is given. It has been shown that there is reasonable agreement between the results obtained by RIA and those obtained by the previously used bioassay. By RIA, a mean normal serum titre of 18 mu/ml erythropoietin has been determined in a study of 445 individuals. Serum erythropoietin results for patients with polycythaemia vera have not been shown to be significantly different from normal values but in patients with secondary polycythaemia, serum titres averaging 94 mu/ml have been found. The predicted physiological changes in erythropoietin titre have also been demonstrated in humans using the RIA; increasing after bleeding and decreasing after red cell administration. Studies of erythropoietin levels in experimental animals have shown that, with the particular antiserum used, the sensitivity of the RIA is markedly reduced.

  17. Clinical indications of prolactin radioimmunoassay

    International Nuclear Information System (INIS)

    Lengyel, A.M.J.; Vieira, J.G.H.; Zanella, M.R.; Zampieri, M.; Chacra, A.R.

    1980-01-01

    Is a review is presented of the main clinical uses of prolactin measurements, including the galactorrhea-amenorrhea syndrome, an experiment employing the prolactin radioimmunoassay is related. (Author) [pt

  18. Automatic computation of radioimmunoassay data

    International Nuclear Information System (INIS)

    Toyota, Takayoshi; Kudo, Mikihiko; Abe, Kanji; Kawamata, Fumiaki; Uehata, Shigeru.

    1975-01-01

    Radioimmunoassay provided dose response curves which showed linearity by the use of logistic transformation (Rodbard). This transformation which was applicable to radioimmunoassay should be useful for the computer processing of insulin and C-peptide assay. In the present studies, standard curves were analysed by testing the fit of analytic functions to radioimmunoassay of insulin and C-peptides. A program for use in combination with the double antibody technique was made by Dr. Kawamata. This approach was evidenced to be useful in order to allow automatic computation of data derived from the double antibody assays of insulin and C-peptides. Automatic corrected calculations of radioimmunoassay data of insulin was found to be satisfactory. (auth.)

  19. Specificity and sensitivity of binding proteins in the radioimmunoassay of cortisol

    International Nuclear Information System (INIS)

    Gijzen, A.H.J.

    1977-01-01

    A comparison concerning avidity towards cortisol and 10 other steroids was made between several binding proteins either in solution or bound to cellulose as so called ''solid phase'' reagent. Human blood cortisol binding protein (CBP, transcortin), and two distinctly different cortisol-binding rabbit antisera and the isolated immunoglobulins thereof were compared in their avidity to bind cortisol and several other steroids. The antisera were harvested from rabbits immunized with either cortisol-21-succinyl-albumin (CSA) or cortisol-3-oxim-albumin (COA). The latter antiserum, having the highest titre in cortisol titration, showed the greatest specificity and was most useful as a binding reagent in cortisol radioimmunoassay when used as a solid phase reagent. The determination of cortisol in micro samples of blood serum is possible without steroid extraction or serum protein denaturation and with only minor influence of steroid impurities in the sample to be analyzed. Affinity constants for all compared binding reagents and steroids are given

  20. Prospective study of radioimmunoassay for antibodies against neutrophil cytoplasm in diagnosis of systemic vasculitis

    International Nuclear Information System (INIS)

    Savage, C.O.S.; Winearls, C.G.; Jones, S.; Marshall, P.D.; Lockwood, C.M.

    1987-01-01

    The diagnosis and management of Wegener's granulomatosis and microscopic polyarteritis are complicated by the lack of specific diagnostic tests. The diagnostic performance of a solid-phase radioimmunoassay, which detects the autoantibodies against neutrophil cytoplasm present in these disorders, was assessed in a prospective study of patients with suspected vasculitis and/or rapidly progressive nephritis. The assay had a sensitivity and specificity of 96% when carried out in combination with a specific inhibition stage and indirect immunofluorescence staining of alcohol-fixed normal neutrophils. (author)

  1. Radioimmunoassay of class-specific antibodies to Streptococcus mutans in monkey serum and saliva

    International Nuclear Information System (INIS)

    Walker, J.; Colman, G.; Huges, M.

    1979-01-01

    A radioimmunoassay (RIA) has been developed to measure class-specific antibodies to Streptococcus mutans in the serum and saliva of monkeys (Macaca fascicularis). Antihuman immunoglobulin antibodies purified by affinity chromatography on immobilised monkey immoglobulins and labelled with 125 I were employed. Formalised cells of S. mutans and an extract of culture supernatant adsorbed to polystyrene wells were used as solid-phase antigens. The coefficients of variation of IgG, IgA, and IgM assays were less than or equal to 10% for both antigen systems. It is shown that this RIA is a sensitive, reproducible and quantitative method. (Auth.)

  2. A radioimmunoassay method for the rapid detection of Candida antibodies is experimental systematic candidiasis

    International Nuclear Information System (INIS)

    Huang, Y.; Berry, W.; Cooper, H.; Zachariah, Y.; Newman, T.

    1979-01-01

    Rabbits were employed as experimental models to evaluate a solid-phase radioimmunoassay (RIA) method for the diagnosis of systematic candidiasis. Ten rabbits were incubated subcutaneously to mimic superficial candidiasis and were found to produce no antibodies to Candida as determined by both immunodiffusion and RIA procedures. However, 94 per cent of 18 rabbits systematically infected by intravenous injection of Candida cells were observed to produce antibody as assessed by the RIA technique. These data encourage further tests with human sera and the continued development of this RIA procedure as a useful tool in the early serodiagnosis of systematic candidiasis. (Auth.)

  3. Radioimmunoassay and some properties of human antibodies to hepatitis B core antigen

    Energy Technology Data Exchange (ETDEWEB)

    Neurath, A R; Szmuness, W; Stevens, C E; Strick, N; Harley, E J [New York Blood Center, N.Y. (USA)

    1978-03-01

    A solid-phase radioimmunoassay for antibodies to hepatitis B core antigen (anti-HBsub(c)) is described. Polystyrene beads coated with anti-HBsub(c), hepatitis B core antigen prepared from pooled sera of humans infected with hepatitis B virus (HBV) and /sup 125/I-labelled anti-HBsub(c) were used for the test. Distinct patterns of development and changes of anti-HBsub(c) and their immunological properties are all related to variations of other markers specific for HBV infections. Knowledge concerning the detailed features of the immune response to hepatitis B core antigen may provide deeper insight into the pathogenesis of HBV infections.

  4. Radioimmunoassay for quantification of anti-tuberculin antibody concentration in guinea pig sera

    Energy Technology Data Exchange (ETDEWEB)

    Mauch, H [Universitaet des Saarlandes, Homburg/Saar (Germany, F.R.). Medizinische Klinik und Poliklinik; Kuemel, G [Universitaet des Saarlandes, Homburg/Saar (Germany, F.R.). Virologische Abt.

    1978-04-01

    A well suited model system for the study of the role of antibodies in immunoregulation is the BCG-infected guinea pig. The assessment of a detailed analysis of the antibody kinetics after BCG infection in comparison to the kinetics of cell-mediated immunity by the delayed type hypersensitivity reaction requires that a specially sensitive, reproducible and precise assay for the determination of antibody concentration is at hand. The methods hitherto available do not meet these requirements. There was developed an indirect double antibody solid phase radioimmunoassay for that purpose.

  5. Radiommunoassay for triiodothyronine in serum. Development of the solid phase technic and comparison with two liquid phase RIA systems: the polyethylene glycol (PEG) and double antibody methods

    International Nuclear Information System (INIS)

    Hamada, M.M.

    1985-01-01

    A solid phase radioimmunoassay (RIA) system for triiodothyronine (T 3 ) was established by immobilizing triiodothyronine antibodies on the inner wall of reaction tubes. The antibody-coated tubes were made via reaction of antibody with glutaraldeyde residue pre coated on the inner wall of the tubes by alkaline self-polimerization. The quality of the coated tubes was tested through its performance in RIA methodology, by analysing the following RIA parameters: minimum detectable dose (MMD), nonspecific binding (NSB), X 50%, slope of the standard curve, intra and inter assay precision, accuracy of the method and figure of merit. The quality and characteristics of the reagents used in the RIA were analysed. (M.A.C.) [pt

  6. Improved resins and novel materials and methods for solid phase extraction and high performance liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Freeze, Ronald [Iowa State Univ., Ames, IA (United States)

    1997-10-08

    Solid-phase extraction (SPE) has grown to be one of the most widely used methods for isolation and preconcentration of a vast range of compounds from aqueous solutions. By modifying polymeric SPE resins with chelating functional groups, the selective uptake of metals was accomplished. The resin, along with adsorbed metals, was vaporized in the ICP and detection of the metals was then possible using either mass or emission spectroscopy. Drug analyses in biological fluids have received heightened attention as drug testing is on the increase both in sports and in the work environment. By using a direct-injection technique, biological fluids can be injected directly into the liquid chromatographic system with no pretreatment. A new surfactant, a sulfonated form of Brij-30 (Brij-S) is shown to prevent the uptake of serum proteins on commercial HPLC columns by forming a thin coating on the silica C18 surface. Excellent separations of eight or more drugs with a wide range of retention times were obtained. The separations had sharper peaks and lower retention times than similar separations performed with the surfactant sodium dodecylsulfate (SDS). Quantitative recovery of a number of drugs with limits of detection near 1 ppm with a 5 μl injection volume were obtained. Finally, a method for solid-phase extraction in a syringe is introduced. The system greatly reduced the volume of solvent required to elute adsorbed analytes from the SPE bed while providing a semi-automated setup. SPE in a syringe consists of a very small bed of resin-loaded membrane packed into a GC or HPLC syringe. After extraction, elution was performed with just a few μl of solvent. This small elution volume allowed injection of the eluent directly from the syringe into the chromatographic system, eliminating the handling problems associated with such small volumes.

  7. Automated solid-phase subcloning based on beads brought into proximity by magnetic force.

    Science.gov (United States)

    Hudson, Elton P; Nikoshkov, Andrej; Uhlen, Mathias; Rockberg, Johan

    2012-01-01

    In the fields of proteomics, metabolic engineering and synthetic biology there is a need for high-throughput and reliable cloning methods to facilitate construction of expression vectors and genetic pathways. Here, we describe a new approach for solid-phase cloning in which both the vector and the gene are immobilized to separate paramagnetic beads and brought into proximity by magnetic force. Ligation events were directly evaluated using fluorescent-based microscopy and flow cytometry. The highest ligation efficiencies were obtained when gene- and vector-coated beads were brought into close contact by application of a magnet during the ligation step. An automated procedure was developed using a laboratory workstation to transfer genes into various expression vectors and more than 95% correct clones were obtained in a number of various applications. The method presented here is suitable for efficient subcloning in an automated manner to rapidly generate a large number of gene constructs in various vectors intended for high throughput applications.

  8. Density-functional theory for fluid-solid and solid-solid phase transitions.

    Science.gov (United States)

    Bharadwaj, Atul S; Singh, Yashwant

    2017-03-01

    We develop a theory to describe solid-solid phase transitions. The density functional formalism of classical statistical mechanics is used to find an exact expression for the difference in the grand thermodynamic potentials of the two coexisting phases. The expression involves both the symmetry conserving and the symmetry broken parts of the direct pair correlation function. The theory is used to calculate phase diagram of systems of soft spheres interacting via inverse power potentials u(r)=ε(σ/r)^{n}, where parameter n measures softness of the potential. We find that for 1/nfcc) structure while for 1/n≥0.154 the body-centred-cubic (bcc) structure is preferred. The bcc structure transforms into the fcc structure upon increasing the density. The calculated phase diagram is in good agreement with the one found from molecular simulations.

  9. Separation and Purification of Sulforaphane from Broccoli by Solid Phase Extraction

    Directory of Open Access Journals (Sweden)

    Kyung Ho Row

    2011-03-01

    Full Text Available A simple solid-phase extraction (SPE method for the determination of sulforaphane in broccoli has been developed. The optimal conditions were found to be use of a silica SPE cartridge, and ethyl acetate and dichloromethane as washing and eluting solvents, respectively, which could eliminate interferences originating from the broccoli matrix. The extracts were sufficiently clean to be directly injected into high-performance liquid chromatography (HPLC for further chromatographic analysis. Good linearity was obtained from 0.05 to 200 μg/mL (r = 0.998 for sulforaphane with the relative standard deviations less than 3.6%. The mean recoveries of sulforaphane from broccoli were more than 90.8% and the detection limit (S/N = 3:1 was 0.02 μg/mL. The SPE method provides a higher yield of sulforaphane from crude extracts compared to conventional liquid-liquid extraction.

  10. Influence of the volume ratio of solid phase on carrying capacity of regular porous structure

    Directory of Open Access Journals (Sweden)

    Monkova Katarina

    2017-01-01

    Full Text Available Direct metal laser sintering is spread technology today. The main advantage of this method is the ability to produce parts which have a very complex geometry and which can be produced only in very complicated way by classical conventional methods. Special category of such components are parts with porous structure, which can give to the product extraordinary combination of properties. The article deals with some aspects that influence the manufacturing of regular porous structures in spite of the fact that input technological parameters at various samples were the same. The main goal of presented research has been to investigate the influence of the volume ratio of solid phase on carrying capacity of regular porous structure. Realized tests have indicated that the unit of regular porous structure with lower volume ratio is able to carry a greater load to failure than the unit with higher volume ratio.

  11. Radioimmunoassay of polypeptide hormones and enzymes

    International Nuclear Information System (INIS)

    Felber, J.P.

    1974-01-01

    General principles of radioimmunoassay are reviewed. Detailed procedures are reviewed for the following hormones: insulin, pituitary hormones, gonadotropins, parathyroid hormone, ACTH, glucagon, gastrin, and peptide hormones. Radioimmunoassay of enzymes is also discussed. (U.S.)

  12. Automated solid-phase peptide synthesis to obtain therapeutic peptides

    Directory of Open Access Journals (Sweden)

    Veronika Mäde

    2014-05-01

    Full Text Available The great versatility and the inherent high affinities of peptides for their respective targets have led to tremendous progress for therapeutic applications in the last years. In order to increase the drugability of these frequently unstable and rapidly cleared molecules, chemical modifications are of great interest. Automated solid-phase peptide synthesis (SPPS offers a suitable technology to produce chemically engineered peptides. This review concentrates on the application of SPPS by Fmoc/t-Bu protecting-group strategy, which is most commonly used. Critical issues and suggestions for the synthesis are covered. The development of automated methods from conventional to essentially improved microwave-assisted instruments is discussed. In order to improve pharmacokinetic properties of peptides, lipidation and PEGylation are described as covalent conjugation methods, which can be applied by a combination of automated and manual synthesis approaches. The synthesis and application of SPPS is described for neuropeptide Y receptor analogs as an example for bioactive hormones. The applied strategies represent innovative and potent methods for the development of novel peptide drug candidates that can be manufactured with optimized automated synthesis technologies.

  13. Solid-phase glycan isolation for glycomics analysis.

    Science.gov (United States)

    Yang, Shuang; Zhang, Hui

    2012-12-01

    Glycosylation is one of the most significant protein PTMs. The biological activities of proteins are dramatically changed by the glycans associated with them. Thus, structural analysis of the glycans of glycoproteins in complex biological or clinical samples is critical in correlation with the functions of glycans with diseases. Profiling of glycans by HPLC-MS is a commonly used technique in analyzing glycan structures and quantifying their relative abundance in different biological systems. Methods relied on MS require isolation of glycans from negligible salts and other contaminant ions since salts and ions may interfere with the glycans, resulting in poor glycan ionization. To accomplish those objectives, glycan isolation and clean-up methods including SPE, liquid-phase extraction, chromatography, and electrophoresis have been developed. Traditionally, glycans are isolated from proteins or peptides using a combination of hydrophobic and hydrophilic columns: proteins and peptides remain on hydrophobic absorbent while glycans, salts, and other hydrophilic reagents are collected as flowthrough. The glycans in the flowthrough are then purified through graphite-activated carbon column by hydrophilic interaction LC. Yet, the drawback in these affinity-based approaches is nonspecific binding. As a result, chemical methods by hydrazide or oxime have been developed for solid-phase isolation of glycans with high specificity and yield. Combined with high-resolution MS, specific glycan isolation techniques provide tremendous potentials as useful tools for glycomics analysis. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Solid phase epitaxy of amorphous silicon carbide: Ion fluence dependence

    International Nuclear Information System (INIS)

    Bae, I.-T.; Ishimaru, Manabu; Hirotsu, Yoshihiko; Sickafus, Kurt E.

    2004-01-01

    We have investigated the effect of radiation damage and impurity concentration on solid phase epitaxial growth of amorphous silicon carbide (SiC) as well as microstructures of recrystallized layer using transmission electron microscopy. Single crystals of 6H-SiC with (0001) orientation were irradiated with 150 keV Xe ions to fluences of 10 15 and 10 16 /cm 2 , followed by annealing at 890 deg. C. Full epitaxial recrystallization took place in a specimen implanted with 10 15 Xe ions, while retardation of recrystallization was observed in a specimen implanted with 10 16 /cm 2 Xe ions. Atomic pair-distribution function analyses and energy dispersive x-ray spectroscopy results suggested that the retardation of recrystallization of the 10 16 Xe/cm 2 implanted sample is attributed to the difference in amorphous structures between the 10 15 and 10 16 Xe/cm 2 implanted samples, i.e., more chemically disordered atomistic structure and higher Xe impurity concentration in the 10 16 Xe/cm 2 implanted sample

  15. Sample preparation with solid phase microextraction and exhaustive extraction approaches: Comparison for challenging cases.

    Science.gov (United States)

    Boyacı, Ezel; Rodríguez-Lafuente, Ángel; Gorynski, Krzysztof; Mirnaghi, Fatemeh; Souza-Silva, Érica A; Hein, Dietmar; Pawliszyn, Janusz

    2015-05-11

    In chemical analysis, sample preparation is frequently considered the bottleneck of the entire analytical method. The success of the final method strongly depends on understanding the entire process of analysis of a particular type of analyte in a sample, namely: the physicochemical properties of the analytes (solubility, volatility, polarity etc.), the environmental conditions, and the matrix components of the sample. Various sample preparation strategies have been developed based on exhaustive or non-exhaustive extraction of analytes from matrices. Undoubtedly, amongst all sample preparation approaches, liquid extraction, including liquid-liquid (LLE) and solid phase extraction (SPE), are the most well-known, widely used, and commonly accepted methods by many international organizations and accredited laboratories. Both methods are well documented and there are many well defined procedures, which make them, at first sight, the methods of choice. However, many challenging tasks, such as complex matrix applications, on-site and in vivo applications, and determination of matrix-bound and free concentrations of analytes, are not easily attainable with these classical approaches for sample preparation. In the last two decades, the introduction of solid phase microextraction (SPME) has brought significant progress in the sample preparation area by facilitating on-site and in vivo applications, time weighted average (TWA) and instantaneous concentration determinations. Recently introduced matrix compatible coatings for SPME facilitate direct extraction from complex matrices and fill the gap in direct sampling from challenging matrices. Following introduction of SPME, numerous other microextraction approaches evolved to address limitations of the above mentioned techniques. There is not a single method that can be considered as a universal solution for sample preparation. This review aims to show the main advantages and limitations of the above mentioned sample

  16. Radioimmunoassay for urinary albumin

    International Nuclear Information System (INIS)

    Woo, J.; Floyd, M.; Cannon, D.C.; Kahan, B.

    1978-01-01

    We describe a rapid, sensitive, and precise radioimmunoassay for urinary albumin (U/sub alb/). Aliquots of diluted urine were incubated at room temperature for 1 h with 125 I-labelled albumin and a rabbit antiserum monospecifid for human albumin. Phase separation was effected by the double-antibody technique. The dose-response curve was linear in the range of 15.6 to 10,000 ng, equivalent to 4 to 3000 mg/liter of urine. The limit of sensitivity was 16 ng of albumin. The coefficient of assay variation was 4.8%, both at 44 mg/liter and at 1304 mg/liter. A displacement curve obtained with a serially diluted urine sample of high albumin concentration was completely superimposable with the curve for which human albumin was used as a standard. In 26 normal individuals the range for U/sub alb/ was 2.2 to 12.6 mg/24 h, and for albumin clearance (C/sub alb/), 1.8 x 10 -5 --19.6 x 10 -5 ml/min. After renal homografts in 25 patients, U/sub alb/ ranged from 16.9 to 9928 mg/24 h, and C/sub alb/ from 2.7 x 10 -4 to 1.7 x 10 -1 ml/min. Both increased U/sub alb/ and C/sub alb/ correlated well with the severity of renal homograft rejection

  17. Radioimmunoassay and related procedures in medicine

    International Nuclear Information System (INIS)

    1978-01-01

    Full text: Radioassay procedures for the measurement of substances such as hormones, vitamins and drugs in the body fluids and tissues, above all in the blood, are now in the front rank of medical applications of radioactive materials. These procedures, which are carried out on specimens in the medical laboratory and do not involve the administration of any radioactive material to the patient, are now widely employed in the routine diagnosis and investigation of disease, whilst their use in research has led to important advances in many branches of medicine. Typical of radioassay methods is radioimmunoassay, which depends on the antigen-antibody reaction between the substance to be measured and the antibodies in an antiserum against that substance produced in a guinea-pig, rabbit, sheep or other animal. The importance of radioimmunoassay was recently underlined by the award of the Nobel Prize in medicine for 1977 to Dr. Rosalyn Yalow of the United States of America for her pioneer work on the method over the past two decades, particularly in relation to the measurement of protein hormones. This symposium was the third on the subject to have been sponsored by the IAEA. The first took place in Vienna in 1969 and the second in Istanbul in 1973. During the four years from 1973 to 1977, the growing commercial availability of reagents and kits for radioassays brought them into routine use. This in turn led to an increasing awareness of the need for assay standardization and quality control and to an increasing attention to techniques of assay data analysis. The burgeoning demands made on assay services stimulated interest in the possibilities for automation of assay procedures. Promising new methods were developed, notably solid-phase radioassay and radioreceptor assay. At the same time there was a resurgence of interest in alternative assay methods not based on the use of radioactive materials, which made a critical re-examination of the entire subject desirable. The

  18. Radioimmunoassay and related procedures in medicine

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1978-02-15

    Full text: Radioassay procedures for the measurement of substances such as hormones, vitamins and drugs in the body fluids and tissues, above all in the blood, are now in the front rank of medical applications of radioactive materials. These procedures, which are carried out on specimens in the medical laboratory and do not involve the administration of any radioactive material to the patient, are now widely employed in the routine diagnosis and investigation of disease, whilst their use in research has led to important advances in many branches of medicine. Typical of radioassay methods is radioimmunoassay, which depends on the antigen-antibody reaction between the substance to be measured and the antibodies in an antiserum against that substance produced in a guinea-pig, rabbit, sheep or other animal. The importance of radioimmunoassay was recently underlined by the award of the Nobel Prize in medicine for 1977 to Dr. Rosalyn Yalow of the United States of America for her pioneer work on the method over the past two decades, particularly in relation to the measurement of protein hormones. This symposium was the third on the subject to have been sponsored by the IAEA. The first took place in Vienna in 1969 and the second in Istanbul in 1973. During the four years from 1973 to 1977, the growing commercial availability of reagents and kits for radioassays brought them into routine use. This in turn led to an increasing awareness of the need for assay standardization and quality control and to an increasing attention to techniques of assay data analysis. The burgeoning demands made on assay services stimulated interest in the possibilities for automation of assay procedures. Promising new methods were developed, notably solid-phase radioassay and radioreceptor assay. At the same time there was a resurgence of interest in alternative assay methods not based on the use of radioactive materials, which made a critical re-examination of the entire subject desirable. The

  19. Complement fixation by solid phase immune complexes. Reduced capacity in SLE sera

    DEFF Research Database (Denmark)

    Baatrup, G; Jonsson, H; Sjöholm, A

    1988-01-01

    We describe an ELISA for assessment of complement function based on the capacity of serum to support fixation of complement components to solid phase immune complexes (IC). Microplates were coated with aggregated bovine serum albumin (BSA) followed by rabbit anti-BSA IgG. The solid phase IC were...

  20. Facile synthesis of aliphatic isothiocyanates and thioureas on solid phase using peptide coupling reagents

    DEFF Research Database (Denmark)

    Boas, Ulrik; Andersen, Heidi Gertz; Christensen, Jørn B.

    2004-01-01

    Peptide coupling reagents can be used as versatile reagents for the formation of aliphatic isothiocyanates and thioureas on solid phase from the corresponding solid-phase anchored aliphatic primary amines. The formation of the thioureas is fast and highly chemoselective, and proceeds via formatio...

  1. Comparative solution and solid-phase glycosylations toward a disaccharide library

    DEFF Research Database (Denmark)

    Agoston, K.; Kröger, Lars; Agoston, Agnes

    2009-01-01

    A comparative study on solution-phase and solid-phase oligosaccharide synthesis was performed. A 16-member library containing all regioisomers of Glc-Glc, Glc-Gal, Gal-Glc, and Gal-Gal disaccharides was synthesized both in solution and on solid phase. The various reaction conditions for different...

  2. Faults of solid-phase welding in titanium joints and their effect on strength

    International Nuclear Information System (INIS)

    Matyushkin, B.A.; Redchits, V.V.

    1982-01-01

    A possibility of the usage of thermal arc energy for the determination of the kinetics of solid-phase joint formation of the VT20 titanium alloy is found out experimentally. Positive action of diffusion annealing upon mechanical properties. of solid-phase joints is explained by the defect elimination

  3. Radioimmunoassay for a human prostate specific antigen

    International Nuclear Information System (INIS)

    Machida, T.; Miki, M.; Ohishi, Y.; Kido, A.; Morikawa, J.; Ogawa, Y.

    1983-01-01

    As a marker for prostatic cancer, a prostate-specific antigen was purified from human prostatic tissues. Double antibody radioimmunoassay utilizing immune reaction was developed on the basis of the purified prostatic antigen (PA). Measurement results have revealed that PA radioimmunoassay is much better than prostatic acid phosphatase (PAP) radioimmunoassay in the diagnosis of prostatic cancer

  4. A linear graph for digoxin radioimmunoassay

    International Nuclear Information System (INIS)

    Smith, S.E.; Richter, A.

    1975-01-01

    The determination of drug or hormone concentrations by radio-immunoassay involves interpolation of values for radioisotope counts within standard curves, a technique which requires some dexterity in curve drawing and which results in some inaccuracy in practice. Most of the procedures designed to overcome these difficulties are complex and time-consuming. In radioimmunoassays involving saturation of the antibody-binding sites a special case exists in that the bound radioactivity is directly proportional to the specific activity of the ligand in the system. Thus a graph of the ratio of radioactivity bound in the absence to that in the presence of added non-radioactive ligand is linear against the concentration of added ligand (Hales,C.N., and Randle, P.J., 1963, Biochem. J., vol. 88, 137). A description is given of a simple and convenient modification of their method, and its application to the routine clinical determination of digoxin using a commercial kit (Lanoxitest β digoxin radioimmunoassay kit, Wellcome Reagents Ltd.). Specially constructed graph paper, which yields linearity with standard solutions, was designed so that it could be used directly without data transmission. The specific activity function appears as the upper arithmetical horizontal scale; corresponding values of the concentration of non-radioactive ligand in the solution added were individually calculated and appear on the lower scale opposite the appropriate values of the upper scale. The linearity of the graphs obtained confirmed that binding of digoxin was approximately constant through the range of clinical concentrations tested (0.5 to 8ng/ml), although binding declined slightly at higher concentrations. (U.K.)

  5. Performance of a Zerovalent Iron Reactive Barrier for the Treatment of Arsenic in Groundwater: Part 2. Geochemical Modeling and Solid Phase Studies

    Science.gov (United States)

    Arsenic uptake processes were evaluated in a zerovalent iron reactive barrier installed at a lead smelting facility using geochemical modeling, solid-phase analysis, and X-ray absorption spectroscopy techniques. Aqueous speciation of arsenic plays a key role in directing arsenic...

  6. MOLECULARLY IMPRINTED SOLID PHASE EXTRACTION FOR TRACE ANALYSIS OF DIAZINON IN DRINKING WATER

    Directory of Open Access Journals (Sweden)

    M. Rahiminejad ، S. J. Shahtaheri ، M. R. Ganjali ، A. Rahimi Forushani ، F. Golbabaei

    2009-04-01

    Full Text Available Amongst organophosphate pesticides, the one most widely used and common environmental contaminant is diazinon; thus methods for its trace analysis in environmental samples must be developed. Use of diazinon imprinted polymers such as sorbents in solid phase extraction, is a prominent and novel application area of molecular imprinted polymers. For diazinon extraction, high performance liquid chromatography analysis was demonstrated in this study. During optimization of the molecular imprinted solid phase extraction procedure for efficient solid phase extraction of diazinon, Plackett-Burman design was conducted. Eight experimental factors with critical influence on molecular imprinted solid phase extraction performance were selected, and 12 different experimental runs based on Plackett-Burman design were carried out. The applicability of diazinon imprinted polymers as the sorbent in solid phase extraction, presented obtained good recoveries of diazinon from LC-grade water. An increase in pH caused an increase in the recovery on molecular imprinted solid phase extraction. From these results, the optimal molecular imprinted solid phase extraction procedure was as follows: solid phase extraction packing with 100 mg diazinon imprinted polymers; conditioning with 5 mL of methanol and 6 mL of LC-grade water; sample loading containing diazinon (pH=10; washing with 1 mL of LC-grade water, 1 mL LC- grade water containing 30% acetonitrile and 0.5 mL of acetonitrile, respectively; eluting with 1 mL of methanol containing 2% acetic acid. The percentage recoveries obtained by the optimized molecular imprinted solid phase extraction were more than 90% with drinking water spiked at different trace levels of diazinon. Generally speaking, the molecular imprinted solid phase extraction procedure and subsequent high performance liquid chromatography analysis can be a relatively fast and proper approach for qualitative and quantitative analysis of diazinon in

  7. Observation of a New High-Pressure Solid Phase in Dynamically Compressed Aluminum

    Science.gov (United States)

    Polsin, D. N.

    2017-10-01

    Aluminum is ideal for testing theoretical first-principles calculations because of the relative simplicity of its atomic structure. Density functional theory (DFT) calculations predict that Al transforms from an ambient-pressure, face-centered-cubic (fcc) crystal to the hexagonal close-packed (hcp) and body-centered-cubic (bcc) structures as it is compressed. Laser-driven experiments performed at the University of Rochester's Laboratory for Laser Energetics and the National Ignition Facility (NIF) ramp compressed Al samples to pressures up to 540 GPa without melting. Nanosecond in-situ x-ray diffraction was used to directly measure the crystal structure at pressures where the solid-solid phase transformations of Al are predicted to occur. Laser velocimetry provided the pressure in the Al. Our results show clear evidence of the fcc-hcp and hpc-bcc transformations at 216 +/- 9 GPa and 321 +/- 12 GPa, respectively. This is the first experimental in-situ observation of the bcc phase in compressed Al and a confirmation of the fcc-hcp transition previously observed under static compression at 217 GPa. The observations indicate these solid-solid phase transitions occur on the order of tens of nanoseconds time scales. In the fcc-hcp transition we find the original texture of the sample is preserved; however, the hcp-bcc transition diminishes that texture producing a structure that is more polycrystalline. The importance of this dynamic is discussed. The NIF results are the first demonstration of x-ray diffraction measurements at two different pressures in a single laser shot. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.

  8. Isolation/separation of plasmid DNA using hemoglobin modified magnetic nanocomposites as solid-phase adsorbent.

    Science.gov (United States)

    Chen, Xu-Wei; Mao, Quan-Xing; Liu, Jia-Wei; Wang, Jian-Hua

    2012-10-15

    Hemoglobin (Hb) modified magnetic nanocomposites are prepared by immobilization of Hb onto the surface of amino-functionalized Fe(3)O(4)@SiO(2) magnetic nanoparticles via covalent bonding with glutaraldehyde as cross-linker. The obtained nanocomposites are characterized with FT-IR, SEM, XRD and surface charge analysis. A direct solid-phase extraction procedure for the isolation/separation of plasmid DNA using this nanocomposite as a novel adsorbent is thus developed. Some important experimental parameters governing the sorption efficiency, i.e., the pH of sample solution and the ionic strength, are investigated. The Hb modified magnetic nanocomposites provide a sorption capacity of 27.86 mg g(-1) for DNA. By using 2.0mg of the nanocomposites as sorption medium and a suitable acidity of pH 6.1, a sorption efficiency of 93% is achieved for 25 μg mL(-1) of DNA in 1.0 mL of sample solution. Afterwards, the absorbed DNA could be readily recovered by using 1.0 mL of Tris-HCl buffer (pH 8.9, 0.01 mol L(-1)), giving rise to a recovery of ca. 68.3%. The present solid-phased extraction protocol is applied for the isolation of plasmid DNA from Escherichia coli culture, resulting in comparable yield and purity of plasmid DNA with respect to those obtained by using commercial kits. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Ultrarapid mutation detection by multiplex, solid-phase chemical cleavage

    Energy Technology Data Exchange (ETDEWEB)

    Rowley, G.; Saad, S.; Giannelli, F.; Green, P.M. [Guy`s & St. Thomas`s Hospitals, London (United Kingdom)

    1995-12-10

    The chemical cleavage of mismatches in heteroduplexes formed by probe and test DNA detects and locates any sequence change in long DNA segments ({approximately}1.8 kb), and its efficiency has been well tested in the analysis of both average (e.g., coagulation factor IX) and large, complex genes (e.g., coagulation factor VIII and dystrophin). In the latter application RT/PCR products allow the examination of all essential sequences of the gene in a minimum number of reactions. We use two specific chemical reactants (hydroxylamine and osmium tetroxide) and piperidine cleavage of the above procedure to develop a very fast mutation screening method. This is based on: (1) 5{prime} or internal fluorescent labeling to allow concurrent screening of three to four DNA fragments and (2) solid-phase chemistry to use a microliter format and reduce the time required for the procedure, from amplification of sequence to gel loading inclusive, to one person-working-day. We test the two variations of the method, one entailing 5{prime} labeling of probe DNA and the other uniform labeling of both probe and target DNA, by detecting 114 known hemophilia B (coagulation factor IX) mutations and by analyzing 129 new patients. Uniform labeling of both probe and target DNA prior to formation of the heteroduplexes leads to almost twofold redundancy in the ability to detect mutations. Alternatively, the latter procedure may offer very efficient though less than 100% screening for sequence changes with only hydroxylamine. The full method with two chemical reactions (hydroxylamine and osmium tetroxide) should allow one person to screen with virtually 100% accuracy more than 300 kb of sequence in three ABI 373 gels in 1 day. 26 refs., 7 figs., 1 tab.

  10. Investigation of impurity-helium solid phase decomposition

    International Nuclear Information System (INIS)

    Boltnev, R.E.; Gordon, E.B.; Krushinskaya, I.N.; Martynenko, M.V.; Pel'menev, A.A.; Popov, E.A.; Khmelenko, V.V.; Shestakov, A.F.

    1997-01-01

    The element composition of the impurity-helium solid phase (IHSP), grown by injecting helium gas jet, involving Ne, Ar, Kr, and Xe atoms and N 2 molecules, into superfluid helium, has been studied. The measured stoichiometric ratios, S = N H e / N I m, are well over the values expected from the model of frozen together monolayer helium clusters. The theoretical possibility for the freezing of two layers helium clusters is justified in the context of the model of IHSP helium subsystem, filled the space between rigid impurity centers. The process of decomposition of impurity-helium (IH)-samples taken out of liquid helium in the temperature range 1,5 - 12 K and the pressure range 10-500 Torr has been studied. It is found that there are two stages of samples decomposition: a slow stage characterized by sample self cooling and a fast one accompanied by heat release. These results suggest, that the IHSP consists of two types of helium - weakly bound and strongly bound helium - that can be assigned to the second and the first coordination helium spheres, respectively, formed around heavy impurity particles. A tendency for enhancement of IHSP thermo stability with increasing the impurity mass is observed. Increase of helium vapor pressure above the sample causes the improvement of IH sample stability. Upon destruction of IH samples, containing nitrogen atoms, a thermoluminescence induced by atom recombination has been detected in the temperature region 3-4,5 K. This suggests that numerous chemical reactions may be realized in solidified helium

  11. Solid-phase thermolysis of hexachlororuthenates (4) of onium type

    Energy Technology Data Exchange (ETDEWEB)

    Kukushkin, Yu N; Maslov, E I; Ryabkova, T P; Lobadyuk, V I [Leningradskij Tekhnologicheskij Inst. (USSR)

    1982-10-01

    Methods of thermogravimetry, infrared spectroscopy, electron absorption spectra and magnetic moment measurings were used to a study thermal solid-phase behaviour of onium hexachlororuthenates (4) of (AH)/sub 2/(RuCl/sub 6/) and (A'H/sub 2/)(RuCl/sub 6/) type, where A-benzimidazole (BAZ), pyridine (py), ammonia, A'-phenanthroline-ortho (o-phen), ethylenediamine (en). It was established that heating of solid (BAZH)/sub 2/(RuCl/sub 6/)x2H/sub 2/O and (o-phen H/sub 2/)(RuCl/sub 6/)xH/sub 2/O in 20-500 deg C range leads to separation of crystallization water and the following extraction of hydrogen chloride with formation of cis-(Ru(BAZ)/sub 2/Cl/sub 4/) and (Ru(o-phen)Cl/sub 4/). (pyH)/sub 2/(RuCl/sub 6/) heating causes initially the separation of two moles of hydrogen chloride with formation of cis-(Ru(py)/sub 2/Cl/sub 4/); further increase of temperature leads to reduction separation of chloride with formation of (Ru(py)/sub 2/Cl/sub 3/)/sub 2/ dimer. The mixture of ruthernium chlorides is prepared under conditions of isothermal heating of (NH/sub 4/)/sub 2/(RuCl/sub 6/) and (enH/sub 2/)(RuCl/sub 6/) compounds at temperatures close to the beginning of their decomposition. The separation of intermediate ruthenium compounds of diamine type with ammonia and ethylendiamine failed.

  12. Radioimmunoassay for human myoglobin

    International Nuclear Information System (INIS)

    Kondo, Akira

    1981-01-01

    1 A new radioimmunoassay (RIA) for human myoglobin (Mb) using two antibody technique was developed as a microassay of Mb. This RIA is characterized as follows; 1) Radioiodination of human Mb was successfully done for the first time by chloramine T method, which yielded Iabelled Mb with high specific activities ranging 40 - 60 μCi/μg. 2) Affinity chromatography was used to obtain purified anti-human Mb antibody, which improved the sensitivity of the RIA remarkably, and excluded the effects of serum and urine. 2 The sensitivity of the RIA was 1 ng/ml in sera and 2 ng/ml in urine. The average recovery was 92.7%. Both intra-assay and inter-assay coefficients of variation were below 10%. 3 With this method, Mb purified from skeletal and cardiac muscles was shown to have same immunological nature. 4 Serum concentrations of Mb in normal adults were 13.1 +- 6.1 ng/ml (mean +- S.D.) with a range of 1 - 28 ng/ml. No sex difference was observed. Urinary Mb Ievels in normal adults were less than 4 ng/ml and 24-hour urinary excretions were less than 6 μg. With this method, serum and urinary Mb concentrations were determined in patients with various disorders such as myopathies and myocardial disorders and with anesthesia. Serum Mb concentrations were revealed to be elevated to 50000 ng/ml in malignant hyperthermia, 4000 ng/ml in acute myocardial infarction, 1000 ng/ml in Duchenne muscular dystrophy and 4000 ng/ml in polymyositis. Urinary Mb level was elevated when serum Mb rose to 2000 - 3000 ng/ml. 5 In order to apply RIA of Mb in daily clinical practices, time needed for the assay was shortened by separation of free and antibody-bound Mb by the polyethylene glycol method immediately after incubation was performed at 37 0 C for 2 hours. (author)

  13. Radioimmunoassay for human myoglobin

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, A. (Tokushima Univ. (Japan). School of Medicine)

    1981-04-01

    1 A new radioimmunoassay (RIA) for human myoglobin (Mb) using two antibody technique was developed as a microassay of Mb. This RIA is characterized as follows; 1) Radioiodination of human Mb was successfully done for the first time by chloramine T method, which yielded Iabelled Mb with high specific activities ranging 40 - 60 ..mu..Ci/..mu..g. 2) Affinity chromatography was used to obtain purified anti-human Mb antibody, which improved the sensitivity of the RIA remarkably, and excluded the effects of serum and urine. 2 The sensitivity of the RIA was 1 ng/ml in sera and 2 ng/ml in urine. The average recovery was 92.7%. Both intra-assay and inter-assay coefficients of variation were below 10%. 3 With this method, Mb purified from skeletal and cardiac muscles was shown to have same immunological nature. 4 Serum concentrations of Mb in normal adults were 13.1 +- 6.1 ng/ml (mean +- S.D.) with a range of 1 - 28 ng/ml. No sex difference was observed. Urinary Mb Ievels in normal adults were less than 4 ng/ml and 24-hour urinary excretions were less than 6 ..mu..g. With this method, serum and urinary Mb concentrations were determined in patients with various disorders such as myopathies and myocardial disorders and with anesthesia. Serum Mb concentrations were revealed to be elevated to 50000 ng/ml in malignant hyperthermia, 4000 ng/ml in acute myocardial infarction, 1000 ng/ml in Duchenne muscular dystrophy and 4000 ng/ml in polymyositis. Urinary Mb level was elevated when serum Mb rose to 2000 - 3000 ng/ml. 5 In order to apply RIA of Mb in daily clinical practices, time needed for the assay was shortened by separation of free and antibody-bound Mb by the polyethylene glycol method immediately after incubation was performed at 37/sup 0/C for 2 hours.

  14. Radioimmunoassay for pyridostigmine

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, H.G.; Lukey, B.J.; Gepp, R.T.; Corpuz, R.P.; Lieske, C.N.

    1988-01-01

    Pyridostigmine is a cholinergic drug used for the treatment of myasthenia gravis and for antagonizing the effects of non-depolarizing muscle relaxants. In addition, military organizations in several countries have an active interest in pyridostigmine as a pretreatment compound for nerve agent poisoning. Anti-pyridostigmine antibodies were produced in rabbits using a pyridostigmine analog conjugated to keyhole limpet hemocyanin. These antibodies were used for development of a radioimmunoassay that has a linear standard curve (r2=0.986) ranging from 0.5 to 10.0 ng/ml of pyridostigmine bromide in a 0.1-ml plasma sample. This assay measures pyridostigmine in plasma with better sensitivity and much greater through-put than do current state-of-the-art high-performance liquid chromatography techniques. In addition, only small volumes (100ml) of the plasma samples are required. Plasma levels of pyridostigmine were determined in the rat after intramuscular administration (0.056mg/kg) of pyridostigmine bromide. Estimates of the various pharmacokinetic parameters were calculated using the computer program NONLIN84. The results were as follows: apparent volume of distribution = 1.97 1/kg, absorption rate constant = 0.277 min-1, elimination rate constant = 0.0273 min-1, area under the curve = 1010 ng x min/ml, absorption rate half-life = 2.41 min, elimination rate half-life = 24.8 min, maximal plasma concentration (Cmax) = 21.3 ng/ml and time to Cmax = 9.02 min.

  15. Peptide radioimmunoassays in clinical medicine

    International Nuclear Information System (INIS)

    Geokas, M.C.; Yalow, R.S.; Straus, E.W.; Gold, E.M.

    1982-01-01

    The radioimmunoassay technique, first developed for the determination of hormones, has been applied to many substances of biologic interest by clinical and research laboratories around the world. It has had an enormous effect in medicine and biology as a diagnostic tool, a guide to therapy, and a probe for the fine structure of biologic systems. For instance, the assays of insulin, gastrin, secretin, prolactin, and certain tissue-specific enzymes have been invaluable in patient care. Further refinements of current methods, as well as the emergence of new immunoassay techniques, are expected to enhance precision, specificity, reliability, and convenience of the radioimmunoassay in both clinical and research laboratories

  16. Radioimmunoassay reagent and its use in a radioimmunoassay

    International Nuclear Information System (INIS)

    Polito, A.J.; Knight, W.S.

    1977-01-01

    A radioimmunoassay to detect or determine a steroid of the cortisone and aldosterone group has been developed. The invention particularly concerns a steroid derivative containing imidazole group which is radioactively labelled. The invented reagents are labelled with iodine 125. (VJ) [de

  17. Local Cloudiness Development Forecast Based on Simulation of Solid Phase Formation Processes in the Atmosphere

    Science.gov (United States)

    Barodka, Siarhei; Kliutko, Yauhenia; Krasouski, Alexander; Papko, Iryna; Svetashev, Alexander; Turishev, Leonid

    2013-04-01

    Nowadays numerical simulation of thundercloud formation processes is of great interest as an actual problem from the practical point of view. Thunderclouds significantly affect airplane flights, and mesoscale weather forecast has much to contribute to facilitate the aviation forecast procedures. An accurate forecast can certainly help to avoid aviation accidents due to weather conditions. The present study focuses on modelling of the convective clouds development and thunder clouds detection on the basis of mesoscale atmospheric processes simulation, aiming at significantly improving the aeronautical forecast. In the analysis, the primary weather radar information has been used to be further adapted for mesoscale forecast systems. Two types of domains have been selected for modelling: an internal one (with radius of 8 km), and an external one (with radius of 300 km). The internal domain has been directly applied to study the local clouds development, and the external domain data has been treated as initial and final conditions for cloud cover formation. The domain height has been chosen according to the civil aviation forecast data (i.e. not exceeding 14 km). Simulations of weather conditions and local clouds development have been made within selected domains with the WRF modelling system. In several cases, thunderclouds are detected within the convective clouds. To specify the given category of clouds, we employ a simulation technique of solid phase formation processes in the atmosphere. Based on modelling results, we construct vertical profiles indicating the amount of solid phase in the atmosphere. Furthermore, we obtain profiles demonstrating the amount of ice particles and large particles (hailstones). While simulating the processes of solid phase formation, we investigate vertical and horizontal air flows. Consequently, we attempt to separate the total amount of solid phase into categories of small ice particles, large ice particles and hailstones. Also, we

  18. Biological treatment of soils contaminated with hydrophobic organics using slurry and solid phase techniques

    International Nuclear Information System (INIS)

    Cassidy, D.P.; Irvine, R.L.

    1995-01-01

    Both slurry-phase and solid-phase bioremediation are effective ex situ soil decontamination methods. Slurry is energy intensive relative to solid-phase treatment, but provides homogenization and uniform nutrient distribution. Limited contaminant bioavailability at concentrations above the required cleanup level reduces biodegradation rates and renders solid phase bioremediation more cost effective than complete treatment in a bioslurry reactor. Slurrying followed by solid-phase bioremediation combines the advantages and minimizes the weaknesses of each treatment method when used alone. A biological treatment system consisting of slurrying followed by aeration in solid phase bioreactors was developed and tested in the laboratory using a silty clay load contaminated with diesel fuel. The first set of experiments was designed to determine the impact of the water content and mixing time during slurrying on the ate and extent of contaminant removal in continuously aerated solid phase bioreactors. The second set of experiments compared the volatile and total diesel fuel removal in solid phase bioreactors using periodic and continuous aeration strategies

  19. Recent advances in steroid radioimmunoassay

    International Nuclear Information System (INIS)

    Jeffcoate, S.L.

    1977-01-01

    The advances since 1974 in the techniques of measuring steroid molecules by radioimmunoassay are reviewed in this paper. They are considered under the following headings: preparation and use of antisera; preparation and use of tracers; preparation of biological samples before assay; dispensing of the reagents in the assay; separation of free and bound radioactivity; counting and data processing; quality control and standardization. (orig.) [de

  20. Biological treatment of soils contaminated with hydrophobic organics using slurry- and solid-phase techniques

    Science.gov (United States)

    Cassidy, Daniel H.; Irvine, Robert L.

    1995-10-01

    Both slurry-phase and solid-phase bioremediation are effective ex situ soil decontamination methods. Slurrying is energy intensive relative to solid-phase treatment, but provides homogenization and uniform nutrient distribution. Limited contaminant bioavailability at concentrations above the required cleanup level reduces biodegradation rates and renders solid phase bioremediation more cost effective than complete treatment in a bio-slurry reactor. Slurrying followed by solid-phase bioremediation combines the advantages and minimizes the weaknesses of each treatment method when used alone. A biological treatment system consisting of slurrying followed by aeration in solid phase bioreactors was developed and tested in the laboratory using a silty clay loam contaminated with diesel fuel. The first set of experiments was designed to determine the impact of the water content and mixing time during slurrying on the rate an extent of contaminant removal in continuously aerated solid phase bioreactors. The second set of experiments compared the volatile and total diesel fuel removal in solid phase bioreactors using periodic and continuous aeration strategies. Results showed that slurrying for 1.5 hours at a water content less than saturation markedly increased the rate and extent of contaminant biodegradation in the solid phase bioreactors compared with soil having no slurry pretreatment. Slurrying the soil at or above its saturation moisture content resulted in lengthy dewatering times which prohibited aeration, thereby delaying the onset of biological treatment in the solid phase bioreactors. Results also showed that properly operated periodic aeration can provide less volatile contaminant removal and a grater fraction of biological contaminant removal than continuous aeration.

  1. Epitope mapping of the carcinoembryonic antigen by monoclonal antibodies and establishment of a new improved radioimmunoassay system

    International Nuclear Information System (INIS)

    Kuroki, Masahide; Arakawa, Fumiko; Matsunaga, Akira; Okamoto, Naomi; Takakura, Kyoko; Matsuoka, Yuji; Higuchi, Hiroshi.

    1987-01-01

    A comprehensive mapping of epitopes on the carcinoembryonic antigen (CEA) molecule has been achieved by analyses of the specificities of 146 monoclonal antibodies (MAbs) from more than 300 hybridomas established recently. The reactivities of MAbs were analyzed by radio-immunoassays (RIA) with highly purified preparations of CEA and related antigens including normal fecal antigen-1 (NFA-1), NFA-2 in normal adult feces, nonspecific cross-reacting antigen (NCA) in lung and NCA-2 in meconium. The MAbs could be divided into five groups: group I, 23 clones directed to the NCA-common part of the CEA molecule; group II, 31 clones directed to the normal fecal cross-reacting antigen (NFCA)-common part; group III, 46 clones directed to the NFA-1-common part; group IV, 33 clones reactive with the heterogeneous carbohydrate part; and group V, 13 clones directed to the CEA-distinctive part which seemed to be highly specific for CEA. Mutual inhibitions of CEA binding between MAbs of the individual groups revealed that at least 25 different subgroups can be defined i.e., 4, 7, 8, 4, and 2 subgroups in groups I to V, respectively. The epitopes recognized by the group IV MAbs were found to be sensitive to oxidation with periodate, while the epitopes defined by MAbs of the other groups were resistant to this treatment. A solid-phase sandwich-type RIA system for CEA was established by using 2 MAbs from groups II and III as the CEA catcher and an MAb of group V as the tracer. This assay was shown to exhibit improved cancer-specificity and accuracy in the estimation of serum CEA levels. (author)

  2. Radioimmunoassay of bleomycin in plasma and urine

    International Nuclear Information System (INIS)

    Teale, J.D.; Clough, J.M.; Marks, V.

    1977-01-01

    Antibodies to bleomycin were raised by immunization of sheep and rabbits with bleomycin-albumin conjugates. The combination of a high-titre, high-avidity sheep antiserum and iodinated bleomycin produced a radioimmunoassay sensitive to 8 ng of bleomycin per ml of plasma or urine. Untreated specimens (100 μl) of plasma or urine could be added directly to the assay tubes. The anti-serum was specific for bleomycin and showed no cross-reaction with other anti-cancer agents used in combination chemotherapy. Over a concentration range of 20 to 100 ng/ml. recovery of bleomycin from plasma was 110% and from urine, 93%. Repeated assay of plasma samples showed a decrease in bleomycin levels unless the samples were kept at 4 0 C or below. Assay of bleomycin levels in plasma and urine from patients under treatment with bleomycin showed similarities with results reported using a microbiological assay. The radioimmunoassay offers a more reliable, rapid and sensitive method for the measurement of bleomycin. (author)

  3. Specific bile acid radioimmunoassays for separate determinations of unconjugated cholic acid, conjugated cholic acid and conjugated deoxycholic acid in serum and their clinical application

    International Nuclear Information System (INIS)

    Matern, S.; Gerok, W.

    1977-01-01

    Specific radioimmunoassays for separate determinations of serum unconjugated cholic, conjugated cholic and conjugated deoxycholic acids have been developed. Prior to the radioimmunoassay, extraction of serum bile acids was performed with Amberlite XAD-2. Unconjugated cholic acid was separated from glyco- and taurocholic acids by thin-layer chromatography. At 50% displacement of bound labeled glyco[ 3 H]cholic acid using antiserum obtained after immunization with cholic acid-bovine serum albumin-conjugate the cross-reactivity of taurocholic acid was 100%, cholic acid 80%, glycochenodeoxycholic acid 10%, chenodeoxycholic acid 7%, conjugated deoxycholic acid 3%, and conjugated lithocholic acid 3 H]cholic acid was linear on a logit-log plot from 5 to 80 pmol of unlabeled glycocholic acid. Fasting serum conjugated cholic acid in healthy subjects was 0.68 +- 0.34 μmol/l. Unconjugated cholic acid was determined by a solid phase radioimmunoassay using the cholic acid antibody chemically bound to Sepharose. The displacement curve of [ 3 H]cholic acid in the solid phase radioimmunoassay was linear on a logit-log plot from 5 to 200 pmol of unlabeled cholic acid. The coefficient of variation between samples was 5%. Fasting serum conjugated deoxycholic acid concentrations in 10 healthy subjects ranged from 0.18 to 0.92 μmol/l determined by a radioimmunoassay using antiserum obtained after immunization with deoxycholic acid-bovine serum albumin-conjugate. The clinical application of these bile acid radioimmunoassays is shown by an 'oral cholate tolerance test' as a sensitive indicator of liver function and by an 'oral cholyglycine tolerance test' as a useful test for bile acid absorption. (orig.) [de

  4. Improved detection limits for phthalates by selective solid-phase micro-extraction

    KAUST Repository

    Zia, Asif I.; Afsarimanesh, Nasrin; Xie, Li; Nag, Anindya; Al-Bahadly, I. H.; Yu, P. L.; Kosel, Jü rgen

    2016-01-01

    Presented research reports on an improved method and enhanced limits of detection for phthalates; a hazardous additive used in the production of plastics by solid-phase micro-extraction (SPME) polymer in comparison to molecularly imprinted solid

  5. Recent Application of Solid Phase Based Techniques for Extraction and Preconcentration of Cyanotoxins in Environmental Matrices.

    Science.gov (United States)

    Mashile, Geaneth Pertunia; Nomngongo, Philiswa N

    2017-03-04

    Cyanotoxins are toxic and are found in eutrophic, municipal, and residential water supplies. For this reason, their occurrence in drinking water systems has become a global concern. Therefore, monitoring, control, risk assessment, and prevention of these contaminants in the environmental bodies are important subjects associated with public health. Thus, rapid, sensitive, selective, simple, and accurate analytical methods for the identification and determination of cyanotoxins are required. In this paper, the sampling methodologies and applications of solid phase-based sample preparation methods for the determination of cyanotoxins in environmental matrices are reviewed. The sample preparation techniques mainly include solid phase micro-extraction (SPME), solid phase extraction (SPE), and solid phase adsorption toxin tracking technology (SPATT). In addition, advantages and disadvantages and future prospects of these methods have been discussed.

  6. Utilizing ion-pairing hydrophilic interaction chromatography solid phase extraction for efficient glycopeptide enrichment in glycoproteomics

    DEFF Research Database (Denmark)

    Mysling, Simon; Palmisano, Giuseppe; Højrup, Peter

    2010-01-01

    Glycopeptide enrichment is a prerequisite to enable structural characterization of protein glycosylation in glycoproteomics. Here we present an improved method for glycopeptide enrichment based on zwitter-ionic hydrophilic interaction chromatography solid phase extraction (ZIC-HILIC SPE...

  7. Preparation and characterization of a novel polymeric based solid-solid phase change heat storage material

    International Nuclear Information System (INIS)

    Xi Peng; Gu Xiaohua; Cheng Bowen; Wang Yufei

    2009-01-01

    Here we reported a two-step procedure for preparing a novel polymeric based solid-solid phase change heat storage material. Firstly, a copolymer monomer containing a polyethylene glycol monomethyl ether (MPEG) phase change unit and a vinyl unit was synthesized via the modification of hydrogen group of MPEG. Secondly, by copolymerization of the copolymer monomer and phenyl ethylene, a novel polymeric based solid-solid phase change heat storage material was prepared. The composition, structure and properties of the novel polymeric based solid-solid phase change material were characterized by IR, 1 H NMR, DSC, WAXD, and POM, respectively. The results show that the novel polymeric based solid-solid phase change material possesses of excellent crystal properties and high phase change enthalpy.

  8. Evaluation of a Solid Phase DNA Binding Matrix for Downstream PCR Analysis

    National Research Council Canada - National Science Library

    Bader, Douglas E; Fisher, Glen R; Stratilo, Chad W

    2005-01-01

    A commercially available solid-phase DNA binding matrix (FTA cards) was evaluated for its ability to capture and release DNA for downstream gene amplification and detection assays using polymerase chain reaction (PCR...

  9. Ion-selective solid-phase electrode sensitive to ammonium ions

    International Nuclear Information System (INIS)

    Vlasov, Yu.G.; Milonova, M.S.; Antonov, P.P.; Bychkov, E.A.; Ehfa, A.Ya.

    1983-01-01

    Ammonium phosphomolybdate is investigated for the purpose of using it as membrane material of ammonium-selective solid-phase electrodes. Estimation of proton mobility and ion conductivity of ammonium phosphomolybdate is performed

  10. Development and application of radioimmunoassay and enzyme immunoassays in microbiological and immunological diagnosis. 3. Comparative studies for the detection of virus antibodies with passive hemagglutination test, radioimmunoassay and enzyme immunoassay, resp

    Energy Technology Data Exchange (ETDEWEB)

    Lauf, H; Struy, H; Morenz, J [Medizinische Akademie, Magdeburg (German Democratic Republic)

    1982-06-01

    Radioimmuno- and enzyme immunoassays (solid phase RIA and ELISA) developed by the authors for the determination of antibodies of adeno-2- and parainfluenza-1-viruses are described and the detection sensibility for antibodies is compared with that of the conventional passive hemagglutination test. The sensibility of the radioimmunoassay for the detection of IgG antibodies against adeno-2-viruses is nearly 10 times higher than that of the passive hemagglutination. RIA and ELISA show no essential differences in their detection sensibilities in the detection of IgG antibodies against parainfluenza-1-viruses.

  11. Passive sampling of ambient ozone by solid phase microextraction with on-fiber derivatization

    International Nuclear Information System (INIS)

    Lee, I-S.; Tsai, S.-W.

    2008-01-01

    The solid phase microextraction (SPME) device with the polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber was used as a passive sampler for ambient ozone. Both O-2,3,4,5,6-(pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) and 1,2-di-(4-pyridyl)ethylene (DPE) were loaded onto the fiber before sampling. The SPME fiber assembly was then inserted into a PTFE tubing as a passive sampler. Known concentrations of ozone around the ambient ground level were generated by a calibrated ozone generator. Laboratory validations of the SPME passive sampler with the direct-reading ozone monitor were performed side-by-side in an exposure chamber at 25 deg. C. After exposures, pyriden-4-aldehyde was formed due to the reaction between DPE and ozone. Further on-fiber derivatizations between pyriden-4-aldehyde and PFBHA were followed and the derivatives, oximes, were then determined by portable gas chromatography with electron capture detector. The experimental sampling rate of the SPME ozone passive sampler was found to be 1.10 x 10 -4 cm 3 s -1 with detection limit of 58.8 μg m -3 h -1 . Field validations with both SPME device and the direct-reading ozone monitor were also performed. The correlations between the results from both methods were found to be consistent with r = 0.9837. Compared with other methods, the current designed sampler provides a convenient and sensitive tool for the exposure assessments of ozone

  12. A rapid solid-phase extraction fluorometric method for thiamine and riboflavin in salmonid eggs

    Science.gov (United States)

    Zajicek, James L.; Tillitt, Donald E.; Brown, Scott B.; Brown, Lisa R.; Honeyfield, Dale C.; Fitzsimons, John D.

    2005-01-01

    A new method has been developed and successfully applied to the selective measurement of thiamine (nonphosphorylated), total thiamine (sum of thiamine, thiamine monophosphate [TMP], thiamine diphosphate [TDP], and thiamine triphosphate [TTP]), and potentially interfering riboflavin in acidic (2% trichloroacetic acid) extracts of selected salmonid and walleye egg samples. Acidic extracts of eggs were applied directly to end-capped C18, reversed-phase solid-phase extraction (SPE) columns and separated into three fractions by elution with mixtures of PO4 buffer (pH 2), methanol (10%), and acetonitrile (20%). All thiamine compounds recovered in the first two fractions were oxidized to their corresponding thiochromes with alkaline potassium hexacyanoferrate, and we measured the thiochrome fluorescence (excitation at 360 nm, emission at 460 nm) in a 96-well microplate reader. Riboflavin, recovered in third fraction (eluted with pH 2, 20% acetonitrile), was analyzed directly by measuring the fluorescence of this fraction (excitation at 450 nm, emission at 530 nm). Significant portions of the phosphate esters of thiamine (TMP, TDP, and presumably TTP), when present at low concentrations (extract thiamine compounds into 2% trichlororacetic acid solution; an inexpensive, commercially available SPE column; small amounts of sample (0.5-1 g); microliter volumes of solvents per sample; a traditional, relatively nonhazardous, oxidation of thiamine compounds to fluorescent thiochromes; and an ultraviolet-visible-wavelength-filter fluorometer for the measurements. ?? Copyright by the American Fisheries Society 2005.

  13. A new procedure for coupling antibody to paper discs for radioimmunoassay: application to the determination of alpha-fetoprotein

    International Nuclear Information System (INIS)

    Sasaki, T.; Tsukada, Y.; Hirai, H.

    1983-01-01

    Horse anti-alpha-fetoprotein was coupled to CM-cellulose discs by a modified carbodiimide reaction. The resulting coupled CM-discs were used in solid-phase radioimmunoassay of human alpha-fetoprotein. The sensitivity of these discs and conventional BrCN activated filter paper discs coupled anti-alpha-fetoprotein was approximately the same. A fair correlation between the alpha-fetoprotein levels determined by both methods was observed. The coupling procedure with carbodiimide is simple and the use of hazardous BrCN is eliminated. (Auth.)

  14. Radioimmunoassay for plasma renin activity

    International Nuclear Information System (INIS)

    1975-01-01

    A radioimmunoassay for the determination of renin activity in blood plasma is described. The plasma sample is mixed with a generator buffer solution also containing an inhibitor for enzymes which convert angiotensin I into other substances. The renin in the plasma sample converts angiotensinogen into angiotensin I. The amount of angiotensin I is then measured with a competitive binding method using 125 I-labelled angiotensin I and antibodies to angiotensin I

  15. Radioimmunoassays of papain in beer

    International Nuclear Information System (INIS)

    Rauch, P.; Fukal, L.; Strejcek, F.; Kas, J.

    1984-01-01

    A radioimmunoassay (RIA) of papain is described which is capable of detecting 0.2 μg of papain/ml in beer, a level approximately 1% of that normally used for chillproofing. Changes in incubation conditions significantly accelerate the papain determination with only slight loss of accuracy. Apart from the high sensitivity it has been shown that the method is highly specific and distinguishes papain from the other chillproofing enzymes used. (author)

  16. The promotion of radioimmunoassay in human health

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1983-01-01

    Radioimmunoassay is an analytical technique which makes use of highly specific and sensitive antibodies to segregate particular substances of interest and radioactive tracers to permit quantification of minute amounts. Some procedures use specific biological ''reagents'' other than antibodies and tracers other than radionuclides. Radioimmunoassay plays an enormous role in medical diagnosis and research. Depending on the services to be performed, the radioimmunoassay laboratories are classified into 4 categories. The laboratory of each category is staffed and equipped with facilities according to its scope and quantity of work. From 1980-1982, nearly US$ 2 million had been used under the Agency's Technical Cooperation Programme for the promotion of radioimmunoassay in human health

  17. Promotion of radioimmunoassay in human health

    Energy Technology Data Exchange (ETDEWEB)

    Dudley, R A [International Atomic Energy Agency, Vienna (Austria). Div. of Life Sciences

    1983-06-01

    Radioimmunoassay is an analytical technique which makes use of highly specific and sensitive antibodies to segregate particular substances of interest and radioactive tracers to permit quantification of minute amounts. Some procedures use specific biological ''reagents'' other than antibodies and tracers other than radionuclides. Radioimmunoassay plays an enormous role in medical diagnosis and research. Depending on the services to be performed, the radioimmunoassay laboratories are classified into 4 categories. The laboratory of each category is staffed and equipped with facilities according to its scope and quantity of work. From 1980-1982, nearly US $2 million had been used under the Agency's Technical Cooperation Programme for the promotion of radioimmunoassay in human health.

  18. Abnormal gas-liquid-solid phase transition behaviour of water observed with in situ environmental SEM.

    Science.gov (United States)

    Chen, Xin; Shu, Jiapei; Chen, Qing

    2017-04-24

    Gas-liquid-solid phase transition behaviour of water is studied with environmental scanning electron microscopy for the first time. Abnormal phenomena are observed. At a fixed pressure of 450 Pa, with the temperature set to -7 °C, direct desublimation happens, and ice grows continuously along the substrate surface. At 550 Pa, although ice is the stable phase according to the phase diagram, metastable liquid droplets first nucleate and grow to ~100-200 μm sizes. Ice crystals nucleate within the large sized droplets, grow up and fill up the droplets. Later, the ice crystals grow continuously through desublimation. At 600 Pa, the metastable liquid grows quickly, with some ice nuclei floating in it, and the liquid-solid coexistence state exists for a long time. By lowering the vapour pressure and/or increasing the substrate temperature, ice sublimates into vapour phase, and especially, the remaining ice forms a porous structure due to preferential sublimation in the concave regions, which can be explained with surface tension effect. Interestingly, although it should be forbidden for ice to transform into liquid phase when the temperature is well below 0 °C, liquid like droplets form during the ice sublimation process, which is attributed to the surface tension effect and the quasiliquid layers.

  19. The Gaseous Phase as a Probe of the Astrophysical Solid Phase Chemistry

    Energy Technology Data Exchange (ETDEWEB)

    Abou Mrad, Ninette; Duvernay, Fabrice; Isnard, Robin; Chiavassa, Thierry; Danger, Grégoire, E-mail: gregoire.danger@univ-amu.fr [Aix-Marseille Université, PIIM UMR-CNRS 7345, F-13397 Marseille (France)

    2017-09-10

    In support of space missions and spectroscopic observations, laboratory experiments on ice analogs enable a better understanding of organic matter formation and evolution in astrophysical environments. Herein, we report the monitoring of the gaseous phase of processed astrophysical ice analogs to determine if the gaseous phase can elucidate the chemical mechanisms and dominant reaction pathways occurring in the solid ice subjected to vacuum ultra-violet (VUV) irradiation at low temperature and subsequently warmed. Simple (CH{sub 3}OH), binary (H{sub 2}O:CH{sub 3}OH, CH{sub 3}OH:NH{sub 3}), and ternary ice analogs (H{sub 2}O:CH{sub 3}OH:NH{sub 3}) were VUV-processed and warmed. The evolution of volatile organic compounds in the gaseous phase shows a direct link between their relative abundances in the gaseous phase, and the radical and thermal chemistries modifying the initial ice composition. The correlation between the gaseous and solid phases may play a crucial role in deciphering the organic composition of astrophysical objects. As an example, possible solid compositions of the comet Lovejoy are suggested using the abundances of organics in its comae.

  20. A review on procedures for the preparation of coatings for solid phase microextraction

    International Nuclear Information System (INIS)

    Aziz-Zanjani, Mohammad Ovais; Mehdinia, Ali

    2014-01-01

    Introduced in the 1990s, solid-phase microextraction (SPME) has found numerous applications. This is due to the solventless nature of SPME and the large variety of sorbents and coatings available. Highly diverse procedures have been applied to coat supports such as fused silica fibers or metal wires with sorbents in order to enhance capability, selectivity and robustness of SPME. Lately, research also is directed towards more simple methods for deposition of different types of coatings. Several of these methods have resulted in better stability and higher effective surface areas of the coatings. This review (with 128 references) covers the state of the art in methods for coating materials for use in SPME. It is divided into the following sections: (a) Dip methods and physical agglutination methods, (b) sol-gel technology, (c) chemical grafting, (d) electrochemical methods for coating (such as electrodeposition, anodizing and electrophoretic deposition), (e) electrospinning, (f) liquidphase deposition, and (g) hydrothermal methods. A final section covers conclusions and future trends. (author)

  1. Improved performance of a double antibody radioimmunoassay for carcinoembryonic antigen

    International Nuclear Information System (INIS)

    Zimmerman, R.

    1979-01-01

    A new double antibody solid-phase radioimmunoassay (RIA) for carcinoembryonic antigen (CEA) is critically analyzed. The aim of the study was 4-fold: (a) to define the level of sensitivity (a comparison of 3 different assay procedures revealed that the author's sequential assay was more sensitive than most previously reported RIAs, while competitive and non-equilibrium assay had wider measuring ranges); (b) to analyze recoveries of CEA in either serum, plasma or urine (the recovery , even in urine, was very close to expected values, indicating that no CEA is lost or degraded during brief storage or in the extraction procedure); (c) to evaluate inter- and intra-assay variations, since most clinical management is dependent on serial assays rather than single determinations. The coefficients of variation were low both within and between assays. A change of 3 ng CEA is required for significant change (>2 S.D.) at the normal serum level which is 16 ng CEA/ml in the authors assay. At levels above normal, a change of 4 ng is required; (d) the assay was also developed for determination of CEA levels in a large series of perchlorid acid treated serum, plasma or urine samples. This forms the basis for an assay suitable for serial assays with high sensitivity and accuracy in various neoplastic diseases. (Auth.)

  2. Human leukocytic pyrogen: purification and development of a radioimmunoassay.

    Science.gov (United States)

    Dinarello, C A; Renfer, L; Wolff, S M

    1977-10-01

    Leukocytic pyrogen is a small endogenous protein that mediates fever. Because of the limitations of bioassays, circulating leukocytic pyrogen has not been demonstrated during fever in humans. The pyrogen was produced in vitro after phagocytosis of staphylococci by blood monocytes. Antibody against the pyrogen was obtained from rabbits immunized with leukocytic pyrogen and the antiserum was purified by solid-phase immunoadsorbants. Purified antibody to the pyrogen was attached to activated Sepharose 4B and used in conjunction with gel filtration to purify the pyrogen. The pyrogen was labeled with 125I and further purified by gel filtration and ion-exchange chromatography. The final preparation of 125I-labeled pyrogen demonstrated a homogeneous band during isoelectric focusing and other separation procedures. With antibody to pyrogen attached to Sepharose, less than 0.1 of a rabbit pyrogenic dose of human leukocytic pyrogen inhibited the binding of 125I-labeled pyrogen to this immunoadsorbant, and this inhibition was not affected by the presence of human serum. Thus, a radioimmunoassay for human leukocytic pyrogen has been developed that may be used to detect circulating pyrogen during fever in humans.

  3. Radioimmunoassay method for detection of gonorrhea antibodies

    International Nuclear Information System (INIS)

    1975-01-01

    A novel radioimmunoassay for the detection of gonorrhea antibodies in serum is described. A radionuclide is bound to gonorrhea antigens produced by a growth culture. In the presence of gonorrhea antibodies in the serum, an antigen-antibody conjugate is formed, the concentration of which can be measured with conventional radiometric methods. The radioimmunoassay is highly specific

  4. Simple fabrication of solid phase microextraction fiber employing nitrogen-doped ordered mesoporous polymer by in situ polymerization.

    Science.gov (United States)

    Zheng, Juan; Liang, Yeru; Liu, Shuqin; Jiang, Ruifen; Zhu, Fang; Wu, Dingcai; Ouyang, Gangfeng

    2016-01-04

    A combination of nitrogen-doped ordered mesoporous polymer (NOMP) and stainless steel wires led to highly sensitive, selective, and stable solid phase microextraction (SPME) fibers by in situ polymerization for the first time. The ordered structure of synthesized NOMP coating was illustrated by transmission electron microscopy (TEM) and X-ray diffraction (XRD), and microscopy analysis by scanning electron microscopy (SEM) confirmed a homogenous morphology of the NOMP-coated fiber. The NOMP-coated fiber was further applied for the extraction of organochlorine pesticides (OCPs) with direct-immersion solid-phase microextraction (DI-SPME) method followed by gas chromatography-mass spectrometry (GC-MS) quantification. Under the optimized conditions, low detection limits (0.023-0.77 ng L(-1)), a wide linear range (9-1500 ng L(-1)), good repeatability (3.5-8.1%, n=6) and excellent reproducibility (1.5-8.3%, n=3) were achieved. Moreover, the practical feasibility of the proposed method was evaluated by determining OCPs in environmental water samples with satisfactory recoveries. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. A multilevel simulation approach to derive the slip boundary condition of the solid phase in two-fluid models

    Science.gov (United States)

    Feng, Zhi-Gang; Michaelides, Efstathios; Mao, Shaolin

    2011-11-01

    The simulation of particulate flows for industrial applications often requires the use of a two-fluid model (TFM), where the solid particles are considered as a separate continuous phase. One of the underlining uncertainties in the use of aTFM in multiphase computations comes from the boundary condition of the solid phase. The no-slip condition at a solid boundary is not a valid assumption for the solid phase. Instead, several researchers advocate a slip condition as a more appropriate boundary condition. However, the question on the selection of an exact slip length or a slip velocity coefficient is still unanswered. In the present work we propose a multilevel simulation approach to compute the slip length that is applicable to a TFM. We investigate the motion of a number of particles near a vertical solid wall, while the particles are in fluidization using a direct numerical simulation (DNS); the positions and velocities of the particles are being tracked and analyzed at each time step. It is found that the time- and vertical-space averaged values of the particle velocities converge, yielding velocity profiles that can be used to deduce the particle slip length close to a solid wall. This work was supported by a grant from the DOE-NETL (DE-NT0008064) and by a grant from NSF (HRD-0932339).

  6. Solid-phase extraction procedures in systematic toxicological analysis

    NARCIS (Netherlands)

    Franke, J.P.; de Zeeuw, R.A

    1998-01-01

    In systematic toxicological analysis (STA) the substance(s) present is (are) not known at the start of the analysis. in such an undirected search the extraction procedure cannot be directed to a given substance but must be a general procedure where a compromise must be reached in that the substances

  7. Haptoglobin radioassay based on binding to solid-phase hemoglobin

    International Nuclear Information System (INIS)

    Hooper, D.C.; Reed, R.A.; Peacock, A.C.

    1979-01-01

    A specific and sensitive assay for haptoglobin based on binding to an easily prepred Sepharose-bound hemoglobin reagent is described. The assay is suitable for directly determining radiolabeled amino acid incorporation into haptoglobin in several liver cell systems in vitro and can be adapted to measure unlabeled free haptoglobin in plasma samples regardlss of the presence of the haptoglobin--hemoglobin complex

  8. Solid-Phase Contact Assay That Uses a lux-Marked Nitrosomonas europaea Reporter Strain To Estimate Toxicity of Bioavailable Linear Alkylbenzene Sulfonate in Soil

    OpenAIRE

    Brandt, Kristian K.; Pedersen, Anders; Sørensen, Jan

    2002-01-01

    Information about in situ toxicity of the bioavailable pools of adsorptive soil pollutants is a prerequisite for proper ecological risk assessment in contaminated soils. Such toxicity data may be obtained by assays allowing for direct exposure of introduced test microorganisms to the toxicants, as they appear in solid solution equilibria in the natural soil. We describe a novel sensitive solid-phase contact assay for in situ toxicity testing of soil pollutants based on a recombinant biolumine...

  9. Microwave assisted solid phase extraction for separation preconcentration sulfamethoxazole in wastewater using tyre based activated carbon as solid phase material prior to spectrophotometric determination

    Science.gov (United States)

    Mogolodi Dimpe, K.; Mpupa, Anele; Nomngongo, Philiswa N.

    2018-01-01

    This work was chiefly encouraged by the continuous consumption of antibiotics which eventually pose harmful effects on animals and human beings when present in water systems. In this study, the activated carbon (AC) was used as a solid phase material for the removal of sulfamethoxazole (SMX) in wastewater samples. The microwave assisted solid phase extraction (MASPE) as a sample extraction method was employed to better extract SMX in water samples and finally the analysis of SMX was done by the UV-Vis spectrophotometer. The microwave assisted solid phase extraction method was optimized using a two-level fractional factorial design by evaluating parameters such as pH, mass of adsorbent (MA), extraction time (ET), eluent ratio (ER) and microwave power (MP). Under optimized conditions, the limit of detection (LOD) and limit of quantification (LOQ) were 0.5 μg L- 1 and 1.7 μg L- 1, respectively, and intraday and interday precision expressed in terms of relative standard deviation were > 6%.The maximum adsorption capacity was 138 mg g- 1 for SMX and the adsorbent could be reused eight times. Lastly, the MASPE method was applied for the removal of SMX in wastewater samples collected from a domestic wastewater treatment plant (WWTP) and river water.

  10. Solid phase fermentation of Helianthus tuberosus for ethanol

    Energy Technology Data Exchange (ETDEWEB)

    Baerwald, G.; Hamad, S.H.

    1989-01-01

    The direct fermentation of pure inulin and hammer mill crushed Helianthus tuberosus tubers (topinambur, Jerusalem artichoke) was studied using two heat-tolerant yeasts, namely Kluyveromyces marxianus and Candida kefyr. A Saccharomyces cerevisiae was included in the study so as to compare the yields of these two yeasts with that of a commercial distiller's yeast. The inulin fermentation was carried out in an 18-L bioreactor using the fed-batch and the batch-fermentation methods. The final ethanol concentration was 6.1% (L/L) which represents 82% of the theoretical yield. Commercial scale experiments with hammer mill crushed tubers gave yields lower than those found in the laboratory: 69% of the theoretical yield for direct fermentation without enzyme addition, and about 91% when cellolytic enzymes were added.

  11. Solid-phase microextraction for bioconcentration studies according to OECD TG 305

    Energy Technology Data Exchange (ETDEWEB)

    Duering, Rolf-Alexander; Boehm, Leonard [Land Use and Nutrition (IFZ) Justus Liebig University Giessen, Institute of Soil Science and Soil Conservation, Research Centre for BioSystems, Giessen (Germany); Schlechtriem, Christian [Fraunhofer Institute for Molecular Biology and Applied Ecology (IME), Schmallenberg (Germany)

    2012-12-15

    An important aim of the European Community Regulation on chemicals and their safe use is the identification of (very) persistent, (very) bioaccumulative, and toxic substances. In other regulatory chemical safety assessments (pharmaceuticals, biocides, pesticides), the identification of such (very) persistent, (very) bioaccumulative, and toxic substances is of increasing importance. Solid-phase microextraction is especially capable of extracting total water concentrations as well as the freely dissolved fraction of analytes in the water phase, which is available for bioconcentration in fish. However, although already well established in environmental analyses to determine and quantify analytes mainly in aqueous matrices, solid-phase microextraction is still a rather unusual method in regulatory ecotoxicological research. Here, the potential benefits and drawbacks of solid-phase microextraction are discussed as an analytical routine approach for aquatic bioconcentration studies according to OECD TG 305, with a special focus on the testing of hydrophobic organic compounds characterized by log K{sub OW}> 5. (orig.)

  12. Tetraphenylimidodiphosphinate as solid phase extractant for preconcentrative separation of thorium from aqueous solution

    International Nuclear Information System (INIS)

    Na Liu; Yanfei Wang; Chuhua He

    2016-01-01

    A simple and reliable method for solid phase extraction of thorium using tetraphenylimidodiphosphinate is presented. The solid phase extraction process was optimized at equilibrium time 3 h, pH = 4.5, initial concentration 30 mg L -1 and extractant dosage 0.01 g with 98.95 % of removal efficiency and 29.68 mg g -1 of adsorption capacity. The interfering ions experiments indicated that it had almost no effect on thorium adsorption. Kinetics data follow the pseudo-first-order model and equilibrium data agreed with the Langmuir isotherm model very well. FT-IR analysis indicated that imino group and phosphoryl acted as the significant roles in the solid phase extraction process. (author)

  13. Solid phase extraction-electrospray ionization mass spectrometric method for the determination of palladium

    International Nuclear Information System (INIS)

    Pranaw Kumar; Telmore, Vijay M.; Jaison, P.G.; Sarkar, Arnab; Alamelu, D.; Aggarwal, S.K.

    2015-01-01

    Platinum group of element (PGEs) are extensively used as a catalyst and anticancer reagent. Due to the soft nature of PGEs, sulphur based donar ligands are used for the separation of these elements. Studies on the formation of different species are helpful for obtaining the ideas about separation of these elements from the complex matrices. Palladium (Pd) is studied as a representative element which is also formed by nuclear fission of fissile nuclides. In view of the relatively small amount of solvent required for separation, solid phase extraction is preferred over most of the separation methods. Solid phase extraction method using DPX as a stationary phase was previously reported for the separation of Pd in SHLLW using benzoylthiourea as a ligand. However, in case of large volume samples manual extraction by DPX is tedious task. In the present studies, the feasibility of extraction using benzoylthiourea on automated solid phase extraction system was carried out for the extraction of Pd

  14. Solid-phase route to Fmoc-protected cationic amino acid building blocks

    DEFF Research Database (Denmark)

    Clausen, Jacob Dahlqvist; Linderoth, Lars; Nielsen, Hanne Mørck

    2012-01-01

    Diamino acids are commonly found in bioactive compounds, yet only few are commercially available as building blocks for solid-phase peptide synthesis. In the present work a convenient, inexpensive route to multiple-charged amino acid building blocks with varying degree of hydrophobicity...... was developed. A versatile solid-phase protocol leading to selectively protected amino alcohol intermediates was followed by oxidation to yield the desired di- or polycationic amino acid building blocks in gram-scale amounts. The synthetic sequence comprises loading of (S)-1-(p-nosyl)aziridine-2-methanol onto...... of simple neutral amino acids as well as analogs displaying high bulkiness or polycationic side chains was prepared. Two building blocks were incorporated into peptide sequences using microwave-assisted solid-phase peptide synthesis confirming their general utility....

  15. A radioimmunoassay for abscisic acid

    International Nuclear Information System (INIS)

    Walton, D.; Dashek, W.; Galson, E.

    1979-01-01

    We have developed a radioimmunoassay (RIA) for abscisic acid (ABA) in the 0.1 ng to 2.5 ng range. Antibodies were obtained from rabbits immunized with ABA bound via its carboxyl group to bovine serum albumin. Cross-reactivity studies indicate that ABA esters are completely cross-reactive with ABA, while trans, trans abscisic acid (t-ABA) phaseic acid (PA) and dihydrophaseic acid (DPA) have much lower but significant cross-reactivities. Purification methods which reduce the levels of cross-reacting substances are described. (orig.) 891 AJ/orig. 892 MKO [de

  16. Radioimmunoassay and other related techniques

    International Nuclear Information System (INIS)

    Zarkawi, Moutaz

    1993-04-01

    The article reviews principles, requirements and reliability criteria of radioimmunoassay (RIA). Since basic reactions involved in RIA and related techniques are derived from reactions which take place in the immune system (IS) of humans and animals, the IS and the way it works will be described. In addition to RIA which involves the use of isotopes as tracers (labels), other non-radioisotopic and recent immunoassay techniques i.e. enzyme-linked immunosorbent assay (ELISA), chemiluminescence immunoassay (CLIA) and fluoroimmunoassay (FIA) will be dealt with. Some important and related terms will be defined and explained. (author). 59 refs., 4 figs

  17. Radioimmunoassay of cholylglycine in serum

    International Nuclear Information System (INIS)

    Wakushima, Tadashi; Yamanishi, Yasuhito; Hirayama, Chisato

    1979-01-01

    Serum levels of cholylglycines (CG) were determined by radioimmunoassay and that of total bile acids (TBA) by enzymatic method. In normal subjects, serum levels of CG, TBA and CG/TBA ratio were 0.6 +- 0.4 μM, 7 +- 2 μM, and 0.08 +- 0.06, respectively. They were increased markedly in acute hepatitis and moderately in chronic hepatitis and cirrhosis. Thus, measurement of serum CG as compared with serum TBA appears to be a sensitive liver test. (author)

  18. Radioimmunoassay in children with glomerulonephritis

    International Nuclear Information System (INIS)

    Ametov, A.S.; Gavryushova, L.P.; Shashinka, M.; Mumladze, Eh.B.; Tvorogova, T.M.; Dakhuk, B.; Dronova, V.I.; Toritsina, D.K.; Petrova, T.V.

    1985-01-01

    Proceeding from a radioimmunoassay of various biologically active substances in the blood and urine (ACTH, cortisol, FSH, LH, prolatin, progesterone, estradiol, plasma renin activity and β 2 -microglobulin) of 220 children with glomerulonephritis change of all indices with relation to the type and gravity of glomerulonephritis as well as renal function was revealed. The nature of influence on corticosteroid and immunosuppressive therapy was shown. The authors consider it appropriate to use the determination of biologically active substances in the blood and urine for a more profound estimation of a child's status

  19. A Photolabile Linker for the Solid-Phase Synthesis of Peptide Hydrazides and Heterocycles

    DEFF Research Database (Denmark)

    Qvortrup, Katrine; Komnatnyy, Vitaly V.; Nielsen, Thomas Eiland

    2014-01-01

    A photolabile hydrazine linker for the solid-phase synthesis of peptide hydrazides and hydrazine-derived heterocycles is presented. The developed protocols enable the efficient synthesis of structurally diverse peptide hydrazides derived from the standard amino adds, including those with side......-chain protected residues at the C-terminal of the resulting peptide hydrazide, and are useful for the synthesis of dihydropyrano[2,3-c]pyrazoles. The linker is compatible with most commonly used coupling reagents and protecting groups for solid-phase peptide synthesis....

  20. Solid-phase extraction and determination of trace elements in environmental samples using naphthalene adsorbent

    International Nuclear Information System (INIS)

    Pourreza, N.

    2004-01-01

    Naphthalene co-precipitated with quaternary ammonium salt such as tetraoctyl ammonium bromide and methyltrioctyl ammonium chloride have been used as adsorbent for solid phase extraction of metal ions such as Hg, Cd and Fe. The metal ions are retained on the adsorbent in a column as their complexes with suitable ligands and eluted by an eluent before instrumental measurements. The optimization of the procedures for solid phase extraction and consequent determination of trace elements and application to environmental samples especially water samples will be discussed. (author)

  1. Use of the 2-chlorotrityl chloride resin for microwave-assisted solid phase peptide synthesis.

    Science.gov (United States)

    Ieronymaki, Matthaia; Androutsou, Maria Eleni; Pantelia, Anna; Friligou, Irene; Crisp, Molly; High, Kirsty; Penkman, Kirsty; Gatos, Dimitrios; Tselios, Theodore

    2015-09-01

    A fast and efficient microwave (MW)-assisted solid-phase peptide synthesis protocol using the 2-chlorotrityl chloride resin and the Fmoc/tBu methodology, has been developed. The established protocol combines the advantages of MW irradiation and the acid labile 2-chlorotrityl chloride resin. The effect of temperature during the MW irradiation, the degree of resin substitution during the coupling of the first amino acids and the rate of racemization for each amino acid were evaluated. The suggested solid phase methodology is applicable for orthogonal peptide synthesis and for the synthesis of cyclic peptides. © 2015 Wiley Periodicals, Inc.

  2. Heterologous radioimmunoassay for arginine vasopressin

    International Nuclear Information System (INIS)

    Shimamoto, K.; Murase, T.; Yamaji, T.

    1976-01-01

    A sensitive and specific radioimmunoassay for arginine vasopressin (AVP) was developed utilizing the antisera against lysine vasopressin (LVP) in combination with a labeled AVP. The assay employs an acetone extraction procedure and detects as little as 0.8 pg. per millimeter of AVP in human plasma. In normal subjects, the mean (+- S.D.) plasma concentration of AVP was 4.9 +- 1.2 pg. per milliliter after fluid deprivation and 1.2 +- 0.4 pg. per milliliter after water loading. Plasma AVP levels correlated significantly with plasma osmolalities. In four patients with diabetes insipidus, plasma AVP concentrations ranged from less than 0.8 to 1.2 pg. per milliliter, whereas six patients with the syndrome of inappropriate ADH secretion showed plasma levels of AVP which correspond to those of the dehydrated state in normal subjects or greater, although plasma osmolalities were low in all cases. It was concluded that the present radioimmunoassay method for AVP provides a useful way of assessing neurohypophyseal function in man

  3. An improved method for the radioimmunoassay of free-thyroxine in serum dialysates

    International Nuclear Information System (INIS)

    Giles, A.F.

    1982-01-01

    A convenient, sensitive radioimmunoassay (using 125 I) of free thyroxine in serum dialysates is described. The method utilizes a solid phase separation system (pre-formed double antibody) and a relatively short incubation period (220 min) with a staggered addition of tracer. Blanks were low and consistent. The normal range for non-pregnant euthyroid samples (n = 59) was 11-23 pmol/l. Third trimester pregnancy samples were mostly within the normal range but at the lower end. Patients on T4 replacement showed a much wider variation in free T4 levels with many samples in the hyperthyroid region. Some hypothyroid samples had undetectable free T4 levels and hyperthyroid samples were frequently greater than 80 pmol/l. (author)

  4. Radioimmunoassay for detecting antibodies against murine malarial parasite antigens: monoclonal antibodies recognizing Plasmodium yoelii antigens

    International Nuclear Information System (INIS)

    Kim, K.J.; Taylor, D.W.; Evans, C.B.; Asofsky, R.

    1980-01-01

    A solid-phase radioimmunoassay (SPRIA) in microtiter wells was established for detecting antibodies against Plasmodium yoelii Ag. The SPRIA was found (1) to require as little as 5 μg of crude parasite Ag per well, (2) to be able to detect 0.5 ng of monoclonal Ab, and (3) to be 10 4 times more sensitive than the indirect fluorescent Ab staining technique. In a modification of the above assay using intact RBC as an Ag, hyperimmune serum showed significant binding to the surface of erythrocytes of mice infected with P. yoelii parasites but not to RBC of normal mice. Hybridomas were prepared by fusing infected mouse spleen cells with myeloma cells. Using the SPRIA, hybrids secreting Ab against P. yoelii 17XL Ag were detected

  5. Evaluation of extraction methods for progesterone determination in rabbit (Oryctolagus cuniculus) feces by radioimmunoassay

    International Nuclear Information System (INIS)

    Korndoerfer, Clotilde Maria; Meirelles, Cyro Ferreira; Bueno, Ives Claudio da Silva; Abdalla, Adibe Luiz

    1998-01-01

    The purpose of this study was to find a practical procedure for the extraction of progesterone (P 4 ) from feces and to determine if the P4 plasma profiles during pregnancy were reflected in total fecal P4 of pregnant rabbits. The rabbit was used as model for the techniques. Plasma and feces were collected from 11 rabbits during a period of 42 days. Three different methods of P4 extraction were used. The total P4 was measured by solid-phase radioimmunoassay (RIA) with 125 I-P4 as the tracer. Results suggested that it was possible to extract total P4 from rabbit feces with methanol and petroleum ether. Plasma and fecal P4 profiles were compared for both pregnant and ovariectomized rabbits. It was possible to differentiate total P4 extracted from day two through 28 after breeding (p<0.01). (author)

  6. Evaluation of extraction methods for progesterone determination in rabbit (Oryctolagus cuniculus) feces by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Korndoerfer, Clotilde Maria; Meirelles, Cyro Ferreira; Bueno, Ives Claudio da Silva; Abdalla, Adibe Luiz [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Secao de Ciencias Animais]. E-mail: cfmeirel@esalq.usp.br

    1998-07-01

    The purpose of this study was to find a practical procedure for the extraction of progesterone (P{sub 4}) from feces and to determine if the P4 plasma profiles during pregnancy were reflected in total fecal P4 of pregnant rabbits. The rabbit was used as model for the techniques. Plasma and feces were collected from 11 rabbits during a period of 42 days. Three different methods of P4 extraction were used. The total P4 was measured by solid-phase radioimmunoassay (RIA) with {sup 125} I-P4 as the tracer. Results suggested that it was possible to extract total P4 from rabbit feces with methanol and petroleum ether. Plasma and fecal P4 profiles were compared for both pregnant and ovariectomized rabbits. It was possible to differentiate total P4 extracted from day two through 28 after breeding (p<0.01). (author)

  7. Radioimmunoassay and characterization of woodchuck hepatitis virus core antigen and antibody

    Energy Technology Data Exchange (ETDEWEB)

    Ponzetto, A; Cote, P J; Ford, E C; Engle, R; Gerin, J L; Cicmanec, J; Shapiro, M; Purcell, R H

    1985-06-01

    Solid-phase radioimmunoassays for woodchuck hepatitis virus core antigen (WHcAg) and antibody (anti-WHc) were developed. WHcAg in woodchuck liver homogenates was characterized by ultracentrifugation in CsCl gradients; both heavy and light cores were obtained from the liver of an animal during acute WHV infection, which is consistent with observations in hepatitis B virus infection in man. Endpoint titers of anti-WHc were higher in chronic WHV carriers than in animals recovered from acute infections. Both IgM and IgG anti-WHc antibodies were produced by infected woodchucks. A survey of colony woodchucks demonstrated that 88/89 animals having one or more markers of past or ongoing WHV infection were positive for anti-WHc. Thus, serum anti-WHc appears to be a sensitive marker of WHV infection.

  8. Sensitive radioimmunoassay for the determination of antibodies to mouse hepatitis virus

    Energy Technology Data Exchange (ETDEWEB)

    Leibowitz, J L [California Univ., San Diego, La Jolla (USA); Fung, L S; Levy, G A [Toronto Univ., Ontario (Canada)

    1983-05-01

    A solid-phase radioimmunoassay is described for the detection of antibodies to mouse hepatitis virus. Viruses were purified by velocity and isopycnic gradient centrifugation and 96-well plastic plates were coated with viral antigens. To allow the detection of most serotypes of low titered antisera, a pool of antigens from several viral serotypes were employed. The second antibody, an affinity-purified goat antimouse immunoglobulin, detects IgG, IgM and IgA antibodies. This assay is more sensitive than either the plaque reduction assay or the commercially available enzyme-linked immunosorbant assay and proved to be useful for screening mouse colonies for the presence of mouse hepatitis virus, following seroconversion in experimental animals and in the production of monoclonal antibodies to both structural and nonstructural proteins.

  9. A sensitive radioimmunoassay for the determination of antibodies to mouse hepatitis virus

    International Nuclear Information System (INIS)

    Leibowitz, J.L.; Fung, L.S.; Levy, G.A.

    1983-01-01

    A solid-phase radioimmunoassay is described for the detection of antibodies to mouse hepatitis virus. Viruses were purified by velocity and isopycnic gradient centrifugation and 96-well plastic plates were coated with viral antigens. To allow the detection of most serotypes of low titered antisera, a pool of antigens from several viral serotypes were employed. The second antibody, an affinity-purified goat antimouse immunoglobulin, detects IgG, IgM and IgA antibodies. This assay is more sensitive than either the plaque reduction assay or the commercially available enzyme-linked immunosorbant assay and proved to be useful for screening mouse colonies for the presence of mouse hepatitis virus, following seroconversion in experimental animals and in the production of monoclonal antibodies to both structural and nonstructural proteins. (Auth.)

  10. Membrane solid-phase extraction: Field application for isolation of polycyclic aromatic hydrocarbons from water samples

    International Nuclear Information System (INIS)

    Furlong, E.T.; Koleis, J.C.; Gates, P.M.

    1995-01-01

    Solid-phase extraction (SPE) membranes (M-SPE) were used to isolate microgram-per-liter to nanogram-per-liter quantities of polycyclic aromatic hydrocarbons (PAH) in 4- to 8-liter ground-water samples from a crude-oil-contaminated ground-water site near Bemidji, Minnesota. The M-SPE method was evaluated (1) under laboratory conditions using reagent water fortified with individual PAH at 1.23 micrograms per liter, and (2) at the Bemidji site. At the site, ground-water samples were processed and PAH isolated using a M-SPE system connected directly to the well pump. Following sample isolation, all M-SPE samples were extracted using dichloromethane and analyzed by gas chromatography-mass spectrometry with selected-ion monitoring. Operationally, the M-SPE method provided a simple means to isolate PAH on site at the wellhead, particularly for anoxic water samples. Acceptable recoveries, ranging from 56 to over 100 percent, were observed for lower molecular weight PAH (naphthalene to pyrene) using the M-SPE method. Recoveries using M-SPE were somewhat lower, but reproducible, for higher molecular weight PAH (chrysene to benzo[ghi]perylene), ranging from 18 to 56 percent. M-SPE provides the capability to collect and field isolate PAH from a sufficiently large number of samples to identify environmental chemical processes occurring at individual compound concentrations of 50 to 1,200 nanograms per liter. Using M-SPE, the potential for facilitated transport of PAH by in situ-derived dissolved organic carbon (DOC) was evaluated at the site. Plots comparing DOC and PAH concentrations indicate that PAH concentrations increase exponentially with linear increases in DOC concentrations

  11. Chromium speciation in environmental samples using a solid phase spectrophotometric method

    Science.gov (United States)

    Amin, Alaa S.; Kassem, Mohammed A.

    2012-10-01

    A solid phase extraction technique is proposed for preconcentration and speciation of chromium in natural waters using spectrophotometric analysis. The procedure is based on sorption of chromium(III) as 4-(2-benzothiazolylazo)2,2'-biphenyldiol complex on dextran-type anion-exchange gel (Sephadex DEAE A-25). After reduction of Cr(VI) by 0.5 ml of 96% concentrated H2SO4 and ethanol, the system was applied to the total chromium. The concentration of Cr(VI) was calculated as the difference between the total Cr and the Cr(III) content. The influences of some analytical parameters such as: pH of the aqueous solution, amounts of 4-(2-benzothiazolylazo)2,2'-biphenyldiol (BTABD), and sample volumes were investigated. The absorbance of the gel, at 628 and 750 nm, packed in a 1.0 mm cell, is measured directly. The molar absorptivities were found to be 2.11 × 107 and 3.90 × 107 L mol-1 cm-1 for 500 and 1000 ml, respectively. Calibration is linear over the range 0.05-1.45 μg L-1 with RSD of <1.85% (n = 8.0). Using 35 mg exchanger, the detection and quantification limits were 13 and 44 ng L-1 for 500 ml sample, whereas for 1000 ml sample were 8.0 and 27 ng L-1, respectively. Increasing the sample volume can enhance the sensitivity. No considerable interferences have been observed from other investigated anions and cations on the chromium speciation. The proposed method was applied to the speciation of chromium in natural waters and total chromium preconcentration in microwave digested tobacco, coffee, tea, and soil samples. The results were simultaneously compared with those obtained using an ET AAS method, whereby the validity of the method has been tested.

  12. immobilization of sheep anti-T3 antibodies on the surface of filter paper discs and use it as a solid phase for detection of triiodothyronine

    International Nuclear Information System (INIS)

    Moustafa, K.A.

    2010-01-01

    immunoassays are the most widely used analytical techniques and have been successfully applied to an extensive range of substances including both large and small molecules, cellular components and viruses. the present study describes the development and validation of a sensitive and specific radioimmunoassay (RIA) for triiodothyronine hormone (T 3 ) quantification using purified anti-T 3 antibodies which immobilized onto the surface of filter paper discs and acts as a solid phase anti-T 3 . also, the purified triiodothyronine was used for tracer and standard preparation. the T 3 -tracer was prepared by using chloramine-T method for iodination of purified T 3 with radio labeled iodine -125. the assay allowed to measure serum T 3 hormone levels with a sensitivity of 0.16 ng/ml. serial T 3 serum sample dilutions were linear. the recovery of T 3 from T 3 serum samples ranged from 83.87 % to 116.1 %. there was a tight correlation between T 3 values measured by the prepared system and by that of commercially available T 3 -RIA kit. in conclusion, the prepared T 3 -RIA system was sensitive, linear, accurate, precise and reproducible.

  13. Automated Solid-Phase Subcloning Based on Beads Brought into Proximity by Magnetic Force

    DEFF Research Database (Denmark)

    Hudson, Elton P.; Nikoshkov, Andrej; Uhlén, Mathias

    2012-01-01

    In the fields of proteomics, metabolic engineering and synthetic biology there is a need for high-throughput and reliable cloning methods to facilitate construction of expression vectors and genetic pathways. Here, we describe a new approach for solid-phase cloning in which both the vector and th...

  14. Dispersive solid-phase imprinting of proteins for the production of plastic antibodies

    DEFF Research Database (Denmark)

    Ashley, Jon; Feng, Xiaotong; Halder, Arnab

    2018-01-01

    We describe a novel dispersive solid-phase imprinting technique for the production of nano-sized molecularly imprinted polymers (nanoMIPs) as plastic antibodies. The template was immobilized on in-house synthesized magnetic microspheres instead of conventional glass beads. As a result, high...

  15. Practical application of solid phase spectrophotometry in analysis of materials and goods of mining and metallurgy

    International Nuclear Information System (INIS)

    Duan Qunzhang

    1999-01-01

    The author reviewed recent development and practical application of solid phase spectrophotometry in analysis of materials and goods of mining-metallurgy. Separation and preconcentration and conditions of coloring determination, sensitivity and range of detection, as well as interference of corresponding method are discussed

  16. The constitutive distributed parameter model of multicomponent chemical processes in gas, fluid and solid phase

    International Nuclear Information System (INIS)

    Niemiec, W.

    1985-01-01

    In the literature of distributed parameter modelling of real processes is not considered the class of multicomponent chemical processes in gas, fluid and solid phase. The aim of paper is constitutive distributed parameter physicochemical model, constructed on kinetics and phenomenal analysis of multicomponent chemical processes in gas, fluid and solid phase. The mass, energy and momentum aspects of these multicomponent chemical reactions and adequate phenomena are utilized in balance operations, by conditions of: constitutive invariance for continuous media with space and time memories, reciprocity principle for isotropic and anisotropic nonhomogeneous media with space and time memories, application of definitions of following derivative and equation of continuity, to the construction of systems of partial differential constitutive state equations, in the following derivative forms for gas, fluid and solid phase. Couched in this way all physicochemical conditions of multicomponent chemical processes in gas, fluid and solid phase are new form of constitutive distributed parameter model for automatics and its systems of equations are new form of systems of partial differential constitutive state equations in sense of phenomenal distributed parameter control

  17. Solid-phase synthesis of head and tail bis-acridinylated peptides

    Czech Academy of Sciences Publication Activity Database

    Šebestík, Jaroslav; Matějka, P.; Hlaváček, Jan; Stibor, I.

    2004-01-01

    Roč. 45, č. 6 (2004), s. 1203-1205 ISSN 0040-4039 R&D Projects: GA ČR GA203/02/1379 Institutional research plan: CEZ:AV0Z4055905 Keywords : 9-amino acridine * solid phase synthesis * head and tail peptide conjugates Subject RIV: CC - Organic Chemistry Impact factor: 2.484, year: 2004

  18. Solid-phase synthesis of an apoptosis-inducing tetrapeptide mimicking the Smac protein

    DEFF Research Database (Denmark)

    Le Quement, Sebastian Thordal; Ishøy, Mette; Petersen, Mette Terp

    2011-01-01

    An approach for the solid-phase synthesis of apoptosis-inducing Smac peptidomimetics is presented. Using a Rink linker strategy, tetrapeptides mimicking the N-4-terminal residue of the Smac protein [(N-Me)AVPF sequence] were synthesized on PEGA resin in excellent purities and yields. Following two...

  19. A convenient procedure for the solid-phase synthesis of hydroxamic acids on PEGA resins

    DEFF Research Database (Denmark)

    Nandurkar, Nitin Subhash; Petersen, Rico; Qvortrup, Katrine

    2011-01-01

    An efficient method for the solid-phase synthesis of hydroxamic acids is described. The method comprises the nucleophilic displacement of esters immobilized on PEGA resins with hydroxylamine/sodium hydroxide in isopropanol. The hydroxyaminolysis protocol is compatible with a broad range of PEGA...

  20. Solid-phase synthesis of polyfunctional polylysine dendrons using aldehyde linkers

    DEFF Research Database (Denmark)

    Svenssen, Daniel K.; Mirsharghi, Sahar; Boas, Ulrik

    2014-01-01

    A straightforward method for the solid-phase synthesis of C-terminally modified polylysine dendrons has been developed by applying bisalkoxybenzaldehyde and trisalkoxybenzaldehyde linkers. The method has been used for the synthesis of polylysine dendrons with a variety of C-terminal ‘tail groups’...

  1. Investigation into process of solid-phase synthesis of calcium vanadates

    International Nuclear Information System (INIS)

    Fotiev, A.A.; Krasnenko, T.I.; Slobodin, B.V.

    1983-01-01

    Processes of solid-phase synthesis of calcium vanadates by Toubandt method, measuring electric conductivity and Ca 45 and V 48 radioactive indicators are investigated. It is shown that reaction diffusion during calcium vanadates production from oxides is ensured by calcium and oxygen ions or calcium ions and electrons through the product layer, as to oxygen - through the gas phase

  2. Critical micelle concentration values for different surfactants measured with solid-phase microextraction fibers

    NARCIS (Netherlands)

    Haftka, Joris J H; Scherpenisse, Peter; Oetter, G??nter; Hodges, Geoff; Eadsforth, Charles V.; Kotthoff, Matthias; Hermens, Joop L M

    The amphiphilic nature of surfactants drives the formation of micelles at the critical micelle concentration (CMC). Solid-phase microextraction (SPME) fibres were used in the present study to measure CMC values of twelve nonionic, anionic, cationic and zwitterionic surfactants. The SPME derived CMC

  3. Influence of Calcium on Microbial Reduction of Solid Phase Uranium (VI)

    International Nuclear Information System (INIS)

    Liu, Chongxuan; Jeon, Byong-Hun; Zachara, John M.; Wang, Zheming

    2007-01-01

    The effect of calcium on microbial reduction of a solid phase U(VI), sodium boltwoodite (NaUO2SiO3OH · 1.5H2O), was evaluated in a culture of a dissimilatory metal-reducing bacterium (DMRB), Shewanella oneidensis strain MR-1. Batch experiments were performed in a non-growth bicarbonate medium with lactate as electron donor at pH 7 buffered with PIPES. Calcium increased both the rate and extent of Na-boltwoodite dissolution by increasing its solubility through the formation of a ternary aqueous calcium-uranyl-carbonate species. The ternary species, however, decreased the rates of microbial reduction of aqueous U(VI). Laser-induced fluorescence spectroscopy (LIFS) and transmission electron microscopy (TEM) revealed that microbial reduction of solid phase U(VI) is a sequentially coupled process of Na-boltwoodite dissolution, U(VI) aqueous speciation, and microbial reduction of dissolved U(VI) to U(IV) that accumulated on bacterial surfaces/periplasm. The overall rates of microbial reduction of solid phase U(VI) can be described by the coupled rates of dissolution and microbial reduction that were both influenced by calcium. The results demonstrated that dissolved U(VI) concentration during microbial reduction was a complex function of solid phase U(VI) dissolution kinetics, aqueous U(VI) speciation, and microbial activity

  4. Recent developments and future trends in solid phase microextraction techniques towards green analytical chemistry.

    Science.gov (United States)

    Spietelun, Agata; Marcinkowski, Łukasz; de la Guardia, Miguel; Namieśnik, Jacek

    2013-12-20

    Solid phase microextraction find increasing applications in the sample preparation step before chromatographic determination of analytes in samples with a complex composition. These techniques allow for integrating several operations, such as sample collection, extraction, analyte enrichment above the detection limit of a given measuring instrument and the isolation of analytes from sample matrix. In this work the information about novel methodological and instrumental solutions in relation to different variants of solid phase extraction techniques, solid-phase microextraction (SPME), stir bar sorptive extraction (SBSE) and magnetic solid phase extraction (MSPE) is presented, including practical applications of these techniques and a critical discussion about their advantages and disadvantages. The proposed solutions fulfill the requirements resulting from the concept of sustainable development, and specifically from the implementation of green chemistry principles in analytical laboratories. Therefore, particular attention was paid to the description of possible uses of novel, selective stationary phases in extraction techniques, inter alia, polymeric ionic liquids, carbon nanotubes, and silica- and carbon-based sorbents. The methodological solutions, together with properly matched sampling devices for collecting analytes from samples with varying matrix composition, enable us to reduce the number of errors during the sample preparation prior to chromatographic analysis as well as to limit the negative impact of this analytical step on the natural environment and the health of laboratory employees. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Automatic reactor for solid-phase synthesis of molecularly imprinted polymeric nanoparticles (MIP NPs) in water.

    Science.gov (United States)

    Poma, Alessandro; Guerreiro, Antonio; Caygill, Sarah; Moczko, Ewa; Piletsky, Sergey

    We report the development of an automated chemical reactor for solid-phase synthesis of MIP NPs in water. Operational parameters are under computer control, requiring minimal operator intervention. In this study, "ready for use" MIP NPs with sub-nanomolar affinity are prepared against pepsin A, trypsin and α-amylase in only 4 hours.

  6. Automatic reactor for solid-phase synthesis of molecularly imprinted polymeric nanoparticles (MIP NPs) in water

    OpenAIRE

    Poma, Alessandro; Guerreiro, Antonio; Caygill, Sarah; Moczko, Ewa; Piletsky, Sergey

    2014-01-01

    We report the development of an automated chemical reactor for solid-phase synthesis of MIP NPs in water. Operational parameters are under computer control, requiring minimal operator intervention. In this study, “ready for use” MIP NPs with sub-nanomolar affinity are prepared against pepsin A, trypsin and α-amylase in only 4 hours.

  7. Microwave-assisted solid-phase Ugi four-component condensations

    DEFF Research Database (Denmark)

    Nielsen, John

    1999-01-01

    An 18-member library was constructed from 2 isocyanides, 3 aldehydes and 3 carboxylic acids via microwave-assisted solid-phase Ugi reactions on TentaGel S RAM. Products of high purity were obtained in moderate to excellent yields after reaction times of 5 minutes or less (irradiation at 60W). (C...

  8. Rapid and convenient semi-automated microwave-assisted solid-phase synthesis of arylopeptoids

    DEFF Research Database (Denmark)

    Rasmussen, Jakob Ewald; Boccia, Marcello Massimo; Nielsen, John

    2014-01-01

    A facile and expedient route to the synthesis of arylopeptoid oligomers (N-alkylated aminomethyl benz-amides) using semi-automated microwave-assisted solid-phase synthesis is presented. The synthesis was optimized for the incorporation of side chains derived from sterically hindered or unreactive...

  9. Solid-phase micro-extraction in bioanalysis, exemplified by lidocaine determination

    NARCIS (Netherlands)

    de Jong, GJ; Koster, EHM

    2000-01-01

    Solid-phase micro-extraction (SPME) is a never sample preparation technique that can be used for gaseous, liquid or solid samples in conjunction with GC, HPLC or CE (e.g. [1]). The use of SPME for the analysis of drugs in biofluids is also becoming popular (e.g. [2]). The principle is that a fused

  10. Solid phase stability of molybdenum under compression: Sound velocity measurements and first-principles calculations

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiulu [Laboratory for Shock Wave and Detonation Physics Research, Institute of Fluid Physics, P.O. Box 919-102, 621900 Mianyang, Sichuan (China); Laboratory for Extreme Conditions Matter Properties, Southwest University of Science and Technology, 621010 Mianyang, Sichuan (China); Liu, Zhongli [Laboratory for Shock Wave and Detonation Physics Research, Institute of Fluid Physics, P.O. Box 919-102, 621900 Mianyang, Sichuan (China); College of Physics and Electric Information, Luoyang Normal University, 471022 Luoyang, Henan (China); Jin, Ke; Xi, Feng; Yu, Yuying; Tan, Ye; Dai, Chengda; Cai, Lingcang [Laboratory for Shock Wave and Detonation Physics Research, Institute of Fluid Physics, P.O. Box 919-102, 621900 Mianyang, Sichuan (China)

    2015-02-07

    The high-pressure solid phase stability of molybdenum (Mo) has been the center of a long-standing controversy on its high-pressure melting. In this work, experimental and theoretical researches have been conducted to check its solid phase stability under compression. First, we performed sound velocity measurements from 38 to 160 GPa using the two-stage light gas gun and explosive loading in backward- and forward-impact geometries, along with the high-precision velocity interferometry. From the sound velocities, we found no solid-solid phase transition in Mo before shock melting, which does not support the previous solid-solid phase transition conclusion inferred from the sharp drops of the longitudinal sound velocity [Hixson et al., Phys. Rev. Lett. 62, 637 (1989)]. Then, we searched its structures globally using the multi-algorithm collaborative crystal structure prediction technique combined with the density functional theory. By comparing the enthalpies of body centered cubic structure with those of the metastable structures, we found that bcc is the most stable structure in the range of 0–300 GPa. The present theoretical results together with previous ones greatly support our experimental conclusions.

  11. Solid-phase extraction of berries’ anthocyanins and evaluation of their antioxidative properties

    Czech Academy of Sciences Publication Activity Database

    Denev, P.; Číž, Milan; Ambrožová, Gabriela; Lojek, Antonín; Yanakieva, I.; Kratchanova, M.

    2010-01-01

    Roč. 123, č. 4 (2010), s. 1055-1061 ISSN 0308-8146 R&D Projects: GA MŠk(CZ) OC08058 Institutional research plan: CEZ:AV0Z50040507; CEZ:AV0Z50040702 Keywords : anthocyanins * solid-phase extraction * berry extracts Subject RIV: BO - Biophysics Impact factor: 3.458, year: 2010

  12. Characterization of rhamnolipids by liquid chromatography/mass spectrometry after solid-phase extraction.

    Science.gov (United States)

    Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko

    2016-04-01

    Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.

  13. [Determination of patulin in fruits and jam by solid phase extraction-ultra performance liquid chromatography].

    Science.gov (United States)

    Lü, Weichao; Shen, Shuchang; Wang, Chao

    2017-11-08

    With magnesium silicate, silica gel, diatomite and calcium sulfate as raw materials, a new solid phase extraction column was prepared through a series of processes of grinding to ethanol homogenate, drying and packing into polypropylene tube. The sample was hydrolyzed by pectinase, extracted by acetonitrile and purified by solid phase extraction. The target compounds were separated on a C18 column (100 mm×2.1 mm, 1.8 μm), using 0.8% (v/v) tetrahydrofuran solution as mobile phase with a flow rate of 0.5 mL/min. The detection wavelength was 276 nm. The effect of pectinase on extraction yield and purification effect of solid-phase extraction column were investigated. The optimum chromatographic conditions were selected. There was a good linear relationship between the peak heights and the mass concentrations of patulin in the range of 0.1 to 10 mg/L with the correlation coefficient ( R 2 ) of 1. The limit of detection for this method was 10.22 μg/kg. The spiked recoveries of samples were 86.58%-94.84% with the relative standard deviations (RSDs) of 1.45%-2.28%. The results indicated that the self-made solid phase extraction column had a good purification efficiency, and the UPLC had a high separation efficiency. The method is simple, accurate and of great significance for the quality and safety control of fruit products.

  14. Technical note: New applications for on-line automated solid phase extraction

    OpenAIRE

    MacFarlane, John D.

    1997-01-01

    This technical note explains the disadvantages of manual solid phase extraction (SPE) techniques and the benefits to be gained with automatic systems. The note reports on a number of general and highly specific applications using the Sample Preparation Unit OSP-2A.

  15. Speciation analysis of aqueous nanoparticulate diclofenac complexes by solid-phase microextraction

    NARCIS (Netherlands)

    Zielinska, K.; Leeuwen, van H.P.; Thibault, S.; Town, R.M.

    2012-01-01

    The dynamic sorption of an organic compound by nanoparticles (NPs) is analyzed by solid-phase microextraction (SPME) for the example case of the pharmaceutical diclofenac in dispersions of impermeable (silica, SiO(2)) and permeable (bovine serum albumin, BSA) NPs. It is shown that only the

  16. Prediction of transport phenomena in near and far field: interaction solid phase/fluid phase

    International Nuclear Information System (INIS)

    Mingarro, E.

    1995-01-01

    The prediction of transport phenomena in near and far field is presented in the present report. The study begins with the analysis of solid phases stability: solubility of storage waste: UO 2 and solubility of radionuclides the redox and sorption-desorption conditions are the last aspects studied to predict the transport phenomena

  17. Chemically and geographically distinct solid-phase iron pools in the Southern Ocean

    CSIR Research Space (South Africa)

    Mtshali, TN

    2012-11-01

    Full Text Available Iron is a limiting nutrient in many parts of the oceans, including the unproductive regions of the Southern Ocean. Although the dominant fraction of the marine iron pool occurs in the form of solid-phase particles, its chemical speciation...

  18. Immunochemical cross-reactivity between albumin and solid-phase adsorbed histamine

    DEFF Research Database (Denmark)

    Poulsen, L K; Nolte, H; Søndergaard, I

    1990-01-01

    For production of an antibody against histamine, this was coupled to human serum albumin (HSA) and used for immunization of rabbits. To test the antiserum, an immunoradiometric assay was developed comprising solid-phase bound histamine, antisera and radiolabelled protein A. Titration and inhibition...

  19. Graft-copolymerization of styrene on polypropylene in the solid phase

    NARCIS (Netherlands)

    Beenen, W.; VanderWal, D.; Janssen, L.P.B.M.; Buijtenhuijs, A.; Hogt, A.H.; Wal, Douwe J. v.d.

    The graft-copolymerization of styrene on PP in the solid phase has been studied under various reaction conditions using a radical initiator. Polymerization kinetics were investigated by DSC experiments and reactions in glass ampoules. The conversion rate and grafting efficiency of styrene appeared

  20. Linkers, resins, and general procedures for solid-phase peptide synthesis

    DEFF Research Database (Denmark)

    Shelton, Anne Pernille Tofteng; Jensen, Knud Jørgen

    2013-01-01

    and linkers for solid-phase synthesis is a key parameter for successful peptide synthesis. This chapter provides an overview of the most common and useful resins and linkers for the synthesis of peptides with C-terminal amides, carboxylic acids, and more. The chapter finishes with robust protocols for general...

  1. The Pictet-Spengler reaction in solid-phase combinatorial chemistry

    DEFF Research Database (Denmark)

    Nielsen, Thomas E; Diness, Frederik; Meldal, Morten

    2003-01-01

    The Pictet-Spengler reaction is an important reaction for the generation of tetrahydro-beta-carbolines and tetrahydroisoquinoline ring systems, which exhibit a range of biological and pharmacological properties. This review covers the solid-phase Pictet-Spengler reaction, as employed in solid...

  2. Dynamic speciation analysis of atrazine in aqueous latex nanoparticle dispersions using solid phase microextraction (SPME)

    NARCIS (Netherlands)

    Benhabib, K.; Town, R.M.; Leeuwen, van H.P.

    2009-01-01

    Solid phase microextraction (SPME) is applied in the dynamic speciation analysis of the pesticide atrazine in an aqueous medium containing sorbing latex nanoparticles. It is found that the overall rate of extraction of the analyte is faster than in the absence of nanoparticles and governed by the

  3. Solid phase microextraction speciation analysis of triclosan in aqueous mediacontaining sorbing nanoparticles

    NARCIS (Netherlands)

    Zielinska, K.

    2014-01-01

    Solid phase microextraction (SPME) is applied in the speciation analysis of the hydrophobic compound triclosan in an aqueous medium containing sorbing SiO2 nanoparticles (NPs). It is found that these NPs, as well as their complexes with triclosan, partition between the bulk medium and the solid

  4. Radioimmunoassays of hidden viral antigens

    International Nuclear Information System (INIS)

    Neurath, A.R.; Strick, N.; Baker, L.; Krugman, S.

    1982-01-01

    Antigens corresponding to infectious agents may be present in biological specimens only in a cryptic form bound to antibodies and, thus, may elude detection. We describe a solid-phase technique for separation of antigens from antibodies. Immune complexes are precipitated from serum by polyethylene glycol, dissociated with NaSCN, and adsorbed onto nitrocellulose or polystyrene supports. Antigens remain topographically separated from antibodies after removal of NaSCN and can be detected with radiolabeled antibodies. Genomes from viruses immobilized on nitrocellulose can be identified by nucleic acid hybridization. Nanogram quantities of sequestered hepatitis B surface and core antigens and picogram amounts of hepatitis B virus DNA were detected. Antibody-bound adenovirus, herpesvirus, and measles virus antigens were discerned by the procedure

  5. Radioimmunoassay of creatine kinase isoenzymes in human serum: isoenzyme MM

    International Nuclear Information System (INIS)

    Van Steirteghem, A.C.; Zweig, M.H.; Schechter, A.N.

    1978-01-01

    Measurement of the mass concentration of serum enzymes by radioimmunoassay provides direct quantitation of specific isoenzymes and may be less subject to some of the limitations of traditional assay procedures for enzymes. We describe the development of a sensitive and specific radioimmunoassay for the muscle isoenzyme of creatine kinase, CK-MM, in human serum. CK-MM, purified from human skeletal muscle, was used to raise high-titer antisera and for iodination by the Chloramine T method. The radioimmunoassay required 50 μl of sample, utilized a double-antibody separation method, and was completed in 24 h. Cross reactivity with CK-BB was virtually zero, 3 to 17 percent with CK-MB. The mass concentration of CK-MM in the serum of healthy subjects ranged from 36 to 1668 μg/liter and correlated closely with total CK enzymatic activity. Serum concentrations of CK-MM from casually selected patients correlated less well with total CK enzymatic activity, suggesting the existence of other CK isoenzymes or the presence of inactive forms

  6. Solid-Phase Extraction Strategies to Surmount Body Fluid Sample Complexity in High-Throughput Mass Spectrometry-Based Proteomics

    Science.gov (United States)

    Bladergroen, Marco R.; van der Burgt, Yuri E. M.

    2015-01-01

    For large-scale and standardized applications in mass spectrometry- (MS-) based proteomics automation of each step is essential. Here we present high-throughput sample preparation solutions for balancing the speed of current MS-acquisitions and the time needed for analytical workup of body fluids. The discussed workflows reduce body fluid sample complexity and apply for both bottom-up proteomics experiments and top-down protein characterization approaches. Various sample preparation methods that involve solid-phase extraction (SPE) including affinity enrichment strategies have been automated. Obtained peptide and protein fractions can be mass analyzed by direct infusion into an electrospray ionization (ESI) source or by means of matrix-assisted laser desorption ionization (MALDI) without further need of time-consuming liquid chromatography (LC) separations. PMID:25692071

  7. Solid-phase crystallization of amorphous silicon on ZnO:Al for thin-film solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Becker, C.; Conrad, E.; Dogan, P.; Fenske, F.; Gorka, B.; Haenel, T.; Lee, K.Y.; Rau, B.; Ruske, F.; Weber, T.; Gall, S.; Rech, B. [Helmholtz-Zentrum Berlin fuer Materialien und Energie (formerly Hahn-Meitner-Institut Berlin), Kekulestr. 5, D-12489 Berlin (Germany); Berginski, M.; Huepkes, J. [Institute of Photovoltaics, Forschungszentrum Juelich GmbH, D-52425 Juelich (Germany)

    2009-06-15

    The suitability of ZnO:Al thin films for polycrystalline silicon (poly-Si) thin-film solar cell fabrication was investigated. The electrical and optical properties of 700 -nm-thick ZnO:Al films on glass were analyzed after typical annealing steps occurring during poly-Si film preparation. If the ZnO:Al layer is covered by a 30 nm thin silicon film, the initial sheet resistance of ZnO:Al drops from 4.2 to 2.2 {omega} after 22 h annealing at 600 C and only slightly increases for a 200 s heat treatment at 900 C. A thin-film solar cell concept consisting of poly-Si films on ZnO:Al coated glass is introduced. First solar cell results will be presented using absorber layers either prepared by solid-phase crystallization (SPC) or by direct deposition at 600 C. (author)

  8. Fractionation, solid-phase immobilization and chemical degradation of long pectin oligogalacturonides. Initial steps towards sequencing of oligosaccharides

    DEFF Research Database (Denmark)

    Guillaumie, Fanny; Justesen, Sune Frederik Lamdahl; Mutenda, K.E.

    2006-01-01

    This work presents the optimized separation of pectin oligomers, their analysis by matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS), their subsequent immobilization to supports, and our initial steps towards solid-support assisted sequencing. The ambient...... were produced in excellent purity (> 95%). Elution of OGAs followed by direct analysis of the peak fractions by MALDI-TOF MS. Purified OGAs (DP 5-7) were chemoselectively immobilized onto aminooxy-terminated polyethylene glycol polyacrylamide (PEGA) supports. Solid-phase anchoring took place...... at the reducing end of the oligosaccharide and resulted in the formation of an oxime linkage. The very high coupling yields confirmed the general suitability of aminooxy-PEGA resins for the immobilization of OGAs of different lengths. The OGA-functionalized PEGA supports were subsequently treated with aq TFA...

  9. Biological nitrate removal from water and wastewater by solid-phase denitrification process.

    Science.gov (United States)

    Wang, Jianlong; Chu, Libing

    2016-11-01

    Nitrate pollution in receiving waters has become a serious issue worldwide. Solid-phase denitrification process is an emerging technology, which has received increasing attention in recent years. It uses biodegradable polymers as both the carbon source and biofilm carrier for denitrifying microorganisms. A vast array of natural and synthetic biopolymers, including woodchips, sawdust, straw, cotton, maize cobs, seaweed, bark, polyhydroxyalkanoate (PHA), polycaprolactone (PCL), polybutylene succinate (PBS) and polylactic acid (PLA), have been widely used for denitrification due to their good performance, low cost and large available quantities. This paper presents an overview on the application of solid-phase denitrification in nitrate removal from drinking water, groundwater, aquaculture wastewater, the secondary effluent and wastewater with low C/N ratio. The types of solid carbon source, the influencing factors, the microbial community of biofilm attached on the biodegradable carriers, the potential adverse effect, and the cost of denitrification process are introduced and evaluated. Woodchips and polycaprolactone are the popular and competitive natural plant-like and synthetic biodegradable polymers used for denitrification, respectively. Most of the denitrifiers reported in solid-phase denitrification affiliated to the family Comamonadaceae in the class Betaproteobacteria. The members of genera Diaphorobacter, Acidovorax and Simplicispira were mostly reported. In future study, more attention should be paid to the simultaneous removal of nitrate and toxic organic contaminants such as pesticide and PPCPs by solid-phase denitrification, to the elucidation of the metabolic and regulatory relationship between decomposition of solid carbon source and denitrification, and to the post-treatment of the municipal secondary effluent. Solid-phase denitrification process is a promising technology for the removal of nitrate from water and wastewater. Copyright © 2016

  10. Development of a solid-phase assay for measurement of proteolytic enzyme activity

    International Nuclear Information System (INIS)

    Varani, J.; Johnson, K.; Kaplan, J.

    1980-01-01

    A solid-phase, plate assay was developed for the measurement of proteolytic enzyme activity. In this assay procedure, radiolabeled substrates were dried onto the surface of microtiter wells. Following drying, the wells were washed two times with saline to remove the nonadherent substrate. When proteolytic enzymes were added to the wells, protein hydrolysis occurred, releasing radioactivity into the supernatant fluid. The amount of protein hydrolysis that occurred was reflected by the amount of radioactivity in the supernatant fluid. When 125 I-hemoglobin was used as the substrate, it was as susceptible to hydrolysis by trypsin in the solid-phase assay as it was in solution in a standard assay procedure. Protease activity from a variety of sources (including from viable cells as well as from extracellular sources) were also able to hydrolyze the hemoglobin on the plate. 125 I-Labeled serum albumen, fibrinogen, and rat pulmonary basement membrane were also susceptible to hydrolysis by trypsin in the solid phase. When [ 14 C]elastin was dried onto the plate, it behaved in a similar manner to elastin in solution. It was resistant to hydrolysis by nonspecific proteases such as trypsin and chymotrypsin but was highly susceptible to hydrolysis by elastase. The solid-phase plate assay has several features which recommended it for routine use. It is as sensitive as standard tube assays (and much more sensitive than routinely used colormetric assays). It is quick and convenient; there are no precipitation, centrifugation, or filtration steps. In addition, very small volumes of radioactive wastes are generated. Another advantage of the solid-phase plate assay is the resistance of the dried substrates to spontaneous breakdown and to microbial contamination. Finally, this assay is suitable for use with viable cells as well as for extracellular proteases

  11. Liquid chromatography tandem mass spectrometry method using solid-phase extraction and bead-beating-assisted matrix solid-phase dispersion to quantify the fungicide tebuconazole in controlled frog exposure study: analysis of water and animal tissue

    DEFF Research Database (Denmark)

    Hansen, Martin; Poulsen, Rikke; Luong, Xuan

    2014-01-01

    and on tissue from exposed and non-exposed adult X. laevis. Using solid-phase extraction (SPE), the analytical method allows for quantification of tebuconazole at concentrations as low as 3.89 pg mL(-1) in 10 mL water samples. Using bead-beating-assisted matrix solid-phase dispersion (MSPD), it was possible...

  12. Determination of amphetamine-type stimulants in oral fluid by solid-phase microextraction and gas chromatography-mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Daniele Z., E-mail: daniele.dzs@dpf.gov.br [Setor Tecnico-Cientifico, Superintendencia Regional do Departamento de Policia Federal no Rio Grande do Sul, 1365 Ipiranga Avenue, Azenha, Zip Code 90160-093 Porto Alegre, Rio Grande do Sul (Brazil); Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Boehl, Paula O.; Comiran, Eloisa; Mariotti, Kristiane C. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil); Pechansky, Flavio [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Duarte, Paulina C.A.V. [Secretaria Nacional de Politicas sobre Drogas (SENAD), Esplanada dos Ministerios, Block ' A' , 5th floor, Zip Code 70050-907 Brasilia, Distrito Federal (Brazil); De Boni, Raquel [Centro de Pesquisa em Alcool e Drogas (CPAD), Hospital de Clinicas de Porto Alegre, Universidade Federal do Rio Grande do Sul, 2350, Ramiro Barcelos Street, Zip Code 90035-903 Porto Alegre, Rio Grande do Sul (Brazil); Froehlich, Pedro E.; Limberger, Renata P. [Programa de Pos-Graduacao em Ciencias Farmaceuticas, Faculdade de Farmacia, Universidade Federal do Rio Grande do Sul, 2752 Ipiranga Avenue, Santana, Zip Code 90610-000 Porto Alegre, Rio Grande do Sul (Brazil)

    2011-06-24

    Graphical abstract: Highlights: > Propylchloroformate derivatization of amphetamine-type stimulants in oral fluid. > Direct immersion solid-phase microextraction/gas chromatography-mass spectrometry. > Linear range 2(4)-256 ng mL{sup -1}, detection limits 0.5-2 ng mL{sup -1}. > Accuracy 98-112%, precision <15% of RSD, recovery 77-112%. > Importance of residual evaluation in checking model goodness-of-fit. - Abstract: A method for the simultaneous identification and quantification of amphetamine (AMP), methamphetamine (MET), fenproporex (FEN), diethylpropion (DIE) and methylphenidate (MPH) in oral fluid collected with Quantisal{sup TM} device has been developed and validated. Thereunto, in-matrix propylchloroformate derivatization followed by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry were employed. Deuterium labeled AMP was used as internal standard for all the stimulants and analysis was performed using the selected ion monitoring mode. The detector response was linear for the studied drugs in the concentration range of 2-256 ng mL{sup -1} (neat oral fluid), except for FEN, whereas the linear range was 4-256 ng mL{sup -1}. The detection limits were 0.5 ng mL{sup -1} (MET), 1 ng mL{sup -1} (MPH) and 2 ng mL{sup -1} (DIE, AMP, FEN), respectively. Accuracy of quality control samples remained within 98.2-111.9% of the target concentrations, while precision has not exceeded 15% of the relative standard deviation. Recoveries with Quantisal{sup TM} device ranged from 77.2% to 112.1%. Also, the goodness-of-fit concerning the ordinary least squares model in the statistical inference of data has been tested through residual plotting and ANOVA. The validated method can be easily automated and then used for screening and confirmation of amphetamine-type stimulants in drivers' oral fluid.

  13. Determination of amphetamine-type stimulants in oral fluid by solid-phase microextraction and gas chromatography-mass spectrometry

    International Nuclear Information System (INIS)

    Souza, Daniele Z.; Boehl, Paula O.; Comiran, Eloisa; Mariotti, Kristiane C.; Pechansky, Flavio; Duarte, Paulina C.A.V.; De Boni, Raquel; Froehlich, Pedro E.; Limberger, Renata P.

    2011-01-01

    Graphical abstract: Highlights: → Propylchloroformate derivatization of amphetamine-type stimulants in oral fluid. → Direct immersion solid-phase microextraction/gas chromatography-mass spectrometry. → Linear range 2(4)-256 ng mL -1 , detection limits 0.5-2 ng mL -1 . → Accuracy 98-112%, precision TM device has been developed and validated. Thereunto, in-matrix propylchloroformate derivatization followed by direct immersion solid-phase microextraction and gas chromatography-mass spectrometry were employed. Deuterium labeled AMP was used as internal standard for all the stimulants and analysis was performed using the selected ion monitoring mode. The detector response was linear for the studied drugs in the concentration range of 2-256 ng mL -1 (neat oral fluid), except for FEN, whereas the linear range was 4-256 ng mL -1 . The detection limits were 0.5 ng mL -1 (MET), 1 ng mL -1 (MPH) and 2 ng mL -1 (DIE, AMP, FEN), respectively. Accuracy of quality control samples remained within 98.2-111.9% of the target concentrations, while precision has not exceeded 15% of the relative standard deviation. Recoveries with Quantisal TM device ranged from 77.2% to 112.1%. Also, the goodness-of-fit concerning the ordinary least squares model in the statistical inference of data has been tested through residual plotting and ANOVA. The validated method can be easily automated and then used for screening and confirmation of amphetamine-type stimulants in drivers' oral fluid.

  14. A sensitive radioimmunoassay for colchicine

    International Nuclear Information System (INIS)

    Scherrmann, J.M.; Boudet, L.; Pontikis, R.; Nguyen-Hoang-Nam; Fournier, E.

    1980-01-01

    A sensitive and rapid radioimmunoassay for colchicine was developed using an antibody raised in goats after injection of N-desacetylthiocolchicine conjugated with bovine serum albumin. The incubation time is short and dextran-coated charcoal was used for the separation. The sensitivity of the assay was 0.35 ng/ml urine or serum. A low cross-reactivity was observed with colchicine derivatives and the other drugs tested. The RIA was applied to the measurement of colchicine in the serum of a patient given a 1mg oral dose of the drug. Peak levels of colchicine were attained at 2 hrs. following administration and the drug was rapidly distributed, the concentration decreasing to < 1 ng/ml by 8 hrs. The 24 and 48 hr. concentrations indicated a prolonged excretion of colchicine and a long elimination half-time. (U.K.)

  15. Radioimmunoassay for nortriptyline and amitriptyline

    International Nuclear Information System (INIS)

    Turner, P.

    1977-01-01

    A description has been given (Aherne, G.W.; Marks, V.; Mould, G.; Stout, G.; Lancet; 1214, June 4 (1977)) of a radioimmunoassay (RIA) technique having advantages for monitoring patient response by estimation of plasma concentrations of nortriptyline and amitriptyline. A wide range of monoamine-reuptake-inhibiting drugs is now used in the treatment of depressive illness. There are other analytical techniques such as gas-liquid chromatography which can be used in the estimation of most of these drugs and their major metabolites, as well as for the identification of some other centrally-acting drugs such as benzodiazepines. The chromatographic technique was able to detect the administration of the wrong drug in one comparative study of two antidepressive drugs. Chromatographic and RIA methods therefore both have their own analytical roles according to the clinical or research problem being investigated. (U.K.)

  16. Improved radioimmunoassay of plasma cortisol

    International Nuclear Information System (INIS)

    Donohue, J.; Sgoutas, D.

    1975-01-01

    We report a simplified radioimmunoassay procedure for determination of plasma cortisol. The method offers the advantage that tracer, antibody, and assay buffer are added in a single step with the use of semi-automated equipment. Thus, critical pipetting procedures are minimized, and assay time is reduced to 4 h. No prior extraction or chromatographic purification of cortisol is required. The procedure is simple, reliable, and accurate. For either between-assay or within-assay determinations, the coefficients of variation are about 6 percent. Our results compare well with those obtained from a procedure that included extraction and chromatographic purification of cortisol in several plasma samples. Conditions for optimizing the assay are also discussed. (auth)

  17. Preparation of albumin radioimmunoassay kit

    International Nuclear Information System (INIS)

    Chen Suoshu; Wang Yanzhen; Wang Zhenshan

    1990-01-01

    This paper presents the preparation of Albumin (Alb) radioimmunoassay kit and its preliminary clinical application. The kit is mainly applied to the measurement of Alb concentration in human urine, adopting second antibody-PEG method. The measurement range is (1-50 μg/ml). The curve obtained with a serially diluted urine sample of high Alb concentration was a straight line. Recovery, detectability, intra- and inter-batch variation coefficients were 95.7%-103.6%, 0.1 μg/ml, 5.8% and 6.4% respectively. The kit was tried out clinically for measuring Alb in urine samples in about 1200 normal individuals and 600 various patients of related renal diseases. The preliminary clinical results show that Alb RIA is conducive to the early diagnosis of kidney function abnormalities

  18. Methadone radioimmunoassay: two simple methods

    International Nuclear Information System (INIS)

    Robinson, K.; Smith, R.N.

    1983-01-01

    Two simple and economical radioimmunoassays for methadone in blood or urine are described. Haemolysis, decomposition, common anticoagulants and sodium fluoride do not affect the results. One assay used commercially-available [1- 3 H](-)-methadone hydrobromide as the label, while the other uses a radioiodinated conjugate of 4-dimethylamino-2,2-diphenylpentanoic acid and L-tyrosine methyl ester. A commercially-available antiserum is used in both assays. Normethadone and α-methadol cross-react to a small extent with the antiserum while methadone metabolites, dextropropoxyphene, dipipanone and phenadoxone have negligible cross-reactivities. The 'cut-offs' of the two assays as described are 30 and 33 ng ml -1 for blood, and 24 and 21 ng ml -1 for urine. The assay using the radioiodinated conjugate can be made more sensitive if required by increasing the specific activity of the label. (author)

  19. Radioimmunoassay method for triiodothyronine and thyroxine

    International Nuclear Information System (INIS)

    Hollander, C.S.

    1975-01-01

    This invention relates to a radioimmunoassay method for triiodothyronine or thyroxine or triiodothyronine and thyroxine present in unextracted serum containing thyroxine binding prealbumin and thyroxine binding globulin. Procedures using 125 I and 131 I are described

  20. Production and use of thyroxine antisera in radioimmunoassay technique

    International Nuclear Information System (INIS)

    Abbas, Sumaia Hussein

    2000-06-01

    This study describes the production of antisera from sheep and its use in the determination of thyroxine hormone (T 4 ) level in serum using radioimmunoassay (RIA) technique. In this study two local sheep (Ovis aris) were subjected to immunization against human T 4 immunogen, sera obtained from both sheep after each injection were subjected to evaluation through titration in a purified and non purified form. The produced antibodies were used to assemble a kit for the determination of total human serum thyroxine. Different separation techniques were tried, (second antibody polyethylene glycol (PEG) assisted precipitation, polystyrene beads and magnetisable particles solid phases). For the PEG assisted precipitation, local antiserum and that produced by the North East Thamus Region Immunoassay (NETRIA donkey anti-sheep serum (DASS) as second antibodies) were tried. The final dilutions of the anti-T 4 antibody used were 1/4000 in a liquid phase using second antibody PEG assisted separation, 1/3000 using magnetizable particles and a dilution of 1/10,000 using polystyrene beads solid phase for separation. Optimization of T 4 assay conditions including incubation temperature and reaction time were done. Tests for T 4 assay validation (linearity, recovery and responsibility) were carried out. For linearity and recovery tests, the regression coefficient ranges were found to be from (0.8 to 0.9) and (0.88 to 0.98) respectively. The assay was found to be reproducible where the coefficients of variation within and between assays were less than 10%. The locally developed assay was found to be comparable with NETRIA assay as a reference method with a correlation coefficient of 0.88, 0.93 and 0.87 for PEG assisted separation, magnetizable particles and polystyrene beads techniques respectively. The clinical validation tests showed a reliable sensitivity, specificity and efficiency with values of 97%, 94% and 96% respectively. When the T 4 concentrations measured using the

  1. A sensitive radioimmunoassay for the detection of monoclonal anti-idiotype antibodies

    International Nuclear Information System (INIS)

    Morahan, G.

    1983-01-01

    A radioimmunoassay was developed in order to detect anti-idiotypic antibodies in the supernatants of hybrid cells. This assay is both sensitive and specific for anti-idiotypic (but not anti-allotypic) antibodies. Monoclonal antibodies present in test supernatants are bound by an anti-immunoglobulin coated solid phase. Subsequent incubation with a source of mouse immunoglobulin 'blocks' unreacted anti-immunoglobulin antibodies on the solid phase. Anti-idiotypic antibodies are then detected by their ability to bind 125 I-labelled idiotype-bearing antibody. This paper describes the use of this assay to detect monoclonal anti-idiotypic antibodies in 2 systems; the cross-reactive idiotype of A/J anti-ABA antibodies, and the idiotype expressed by the myeloma protein HOPC 8. Similarly, 125 I-labelled anti-idiotype antibodies may be used in this assay to detect monoclonal idiotype-bearing antibodies. Further modifications are described which would allow the detection of monoclonal anti-allotype antibodies. (Auth.)

  2. Determination of ciprofloxacin in Jiaozhou Bay using molecularly imprinted solid-phase extraction followed by high-performance liquid chromatography with fluorescence detection

    International Nuclear Information System (INIS)

    Lian, Ziru; Wang, Jiangtao

    2016-01-01

    A high selective pre-treatment method for the cleanup and preconcentration of ciprofloxacin in natural seawater samples was developed based on molecularly imprinted solid-phase extraction (MISPE). The ciprofloxacin imprinted polymers were synthesized and the characteristics of obtained polymers were evaluated by scanning electron microscopy, Fourier transform infrared spectroscopy and binding experiments. The imprinted materials showed high adsorption ability for ciprofloxacin and were applied as special solid-phase extraction sorbents for selective separation of ciprofloxacin. An off-line MISPE procedure was optimized and the developed MISPE method allowed direct purification and enrichment of the ciprofloxacin from the aqueous samples prior to high-performance liquid chromatography analysis. The recoveries of spiked seawater on the MISPE cartridges ranged from 75.2 to 112.4% and the relative standard deviations were less than 4.46%. Five seawater samples from Jiaozhou Bay were analyzed and ciprofloxacin was detected in two samples with the concentrations of 0.24 and 0.38 μg L −1 , respectively. - Highlights: • Ciprofloxacin molecularly imprinted polymers (Cip-MIPs) were prepared. • The characteristics and recognition efficiency of MIPs were studied. • An off-line method for Cip was developed using MIPs as solid-phase extraction. • Cip in five seawater samples from Jiaozhou Bay of China was determined.

  3. Matrix solid-phase dispersion coupled with homogeneous ionic liquid microextraction for the determination of sulfonamides in animal tissues using high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Zhibing; He, Mengyu; Jiang, Chunzhu; Zhang, Fengqing; Du, Shanshan; Feng, Wennan; Zhang, Hanqi

    2015-12-01

    Matrix solid-phase dispersion coupled with homogeneous ionic liquid microextraction was developed and applied to the extraction of some sulfonamides, including sulfamerazine, sulfamethazine, sulfathiazole, sulfachloropyridazine, sulfadoxine, sulfisoxazole, and sulfaphenazole, in animal tissues. High-performance liquid chromatography was applied to the separation and determination of the target analytes. The solid sample was directly treated by matrix solid-phase dispersion and the eluate obtained was treated by homogeneous ionic liquid microextraction. The ionic liquid was used as the extraction solvent in this method, which may result in the improvement of the recoveries of the target analytes. To avoid using organic solvent and reduce environmental pollution, water was used as the elution solvent of matrix solid-phase dispersion. The effects of the experimental parameters on recoveries, including the type and volume of ionic liquid, type of dispersant, ratio of sample to dispersant, pH value of elution solvent, volume of elution solvent, amount of salt in eluate, amount of ion-pairing agent (NH4 PF6 ), and centrifuging time, were evaluated. When the present method was applied to the analysis of animal tissues, the recoveries of the analytes ranged from 85.4 to 118.0%, and the relative standard deviations were lower than 9.30%. The detection limits for the analytes were 4.3-13.4 μg/kg. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Determination of haloacetic acids in water using layered double hydroxides as a sorbent in dispersive solid-phase extraction followed by liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Alsharaa, Abdulnaser; Sajid, Muhammad; Basheer, Chanbasha; Alhooshani, Khalid; Lee, Hian Kee

    2016-09-01

    In the present study, highly efficient and simple dispersive solid-phase extraction procedure for the determination of haloacetic acids in water samples has been established. Three different types of layered double hydroxides were synthesized and used as a sorbent in dispersive solid-phase extraction. Due to the interesting behavior of layered double hydroxides in an acidic medium (pH˂4), the analyte elution step was not needed; the layered double hydroxides are simply dissolved in acid immediately after extraction to release the analytes which are then directly introduced into a liquid chromatography with tandem mass spectrometry system for analysis. Several dispersive solid-phase extraction parameters were optimized to increase the extraction efficiency of haloacetic acids such as temperature, extraction time and pH. Under optimum conditions, good linearity was achieved over the concentration range of 0.05-100 μg/L with detection limits in the range of 0.006-0.05 μg/L. The relative standard deviations were 0.33-3.64% (n = 6). The proposed method was applied to different water samples collected from a drinking water plant to determine the concentrations of haloacetic acids. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Validation of a radioimmunoassay for rat insulin

    International Nuclear Information System (INIS)

    Delattre, E.; Boschero, A.C.

    1984-01-01

    A methodological approach that permits, in a radioimmunoassay, the evaluation of rat insulin by using bovine insulin as reference is presented. As in general the technics for radioimmunoassay of different substances follow the same principles (competitive inhibition), we believe that the methodology presented here could be used for evaluation of other hormones when the adequated referential, of know biological activity, is not available. (Author) [pt

  6. A photolabile linker for the solid-phase synthesis of 4-substituted NH-1,2,3-triazoles

    DEFF Research Database (Denmark)

    Qvortrup, Katrine; Nielsen, Thomas Eiland

    2011-01-01

    A novel photolabile linker for solid-phase synthesis is presented. The linker displays an azido handle for copper-catalyzed azide–alkyne cycloaddition reactions with a variety of alkynes, remains intact under typical solid-phase reaction conditions, and enables a mild photolytic release of 4...

  7. On-line solid phase selective separation and preconcentration of Cd(II) by solid-phase extraction using carbon active modified with methyl thymol blue

    Energy Technology Data Exchange (ETDEWEB)

    Ensafi, Ali A. [College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)], E-mail: Ensafi@cc.iut.ac.ir; Ghaderi, Ali R. [College of Chemistry, Isfahan University of Technology, Isfahan 84156-83111 (Iran, Islamic Republic of)

    2007-09-05

    An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5 M HNO{sub 3} and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 {mu}g of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5 M HNO{sub 3} solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ng mL{sup -1} Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ng mL{sup -1} Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments.

  8. On-line solid phase selective separation and preconcentration of Cd(II) by solid-phase extraction using carbon active modified with methyl thymol blue

    International Nuclear Information System (INIS)

    Ensafi, Ali A.; Ghaderi, Ali R.

    2007-01-01

    An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5 M HNO 3 and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 μg of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5 M HNO 3 solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ng mL -1 Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ng mL -1 Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments

  9. On-line solid phase selective separation and preconcentration of Cd(II) by solid-phase extraction using carbon active modified with methyl thymol blue.

    Science.gov (United States)

    Ensafi, Ali A; Ghaderi, Ali R

    2007-09-05

    An on-line flow system was used to develop a selective and efficient on-line sorbent extraction preconcentration system for cadmium. The method is based on adsorption of cadmium ions onto the activated carbon modified with methyl thymol blue. Then the adsorbed ions were washed using 0.5M HNO(3) and the eluent was used to determine the Cd(II) ions using flame atomic absorption spectrometry. The results obtained show that the modified activated carbon has the greatest adsorption capacity of 80 microg of Cd(II) per 1.0 g of the solid phase. The optimal pH value for the quantitative preconcentration was 9.0 and full desorption is achieved by using 0.5M HNO(3) solution. It is established that the solid phase can be used repeatedly without a considerable adsorption capacity loss. The detection limit was less than 1 ngmL(-1) Cd(II), with an enrichment factor of 1000. The calibration graph was linear in the range of 1-2000 ngmL(-1) Cd(II). The developed method has been applied to the determination of trace cadmium (II) in water samples and in the following reference materials: sewage sludge (CRM144R), and sea water (CASS.4) with satisfactory results. The accuracy was assessed through recovery experiments.

  10. Carbon nanotubes as adsorbent of solid-phase extraction and matrix for laser desorption/ionization mass spectrometry.

    Science.gov (United States)

    Pan, Chensong; Xu, Songyun; Zou, Hanfa; Guo, Zhong; Zhang, Yu; Guo, Baochuan

    2005-02-01

    A method with carbon nanotubes functioning both as the adsorbent of solid-phase extraction (SPE) and the matrix for matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) to analyze small molecules in solution has been developed. In this method, 10 microL suspensions of carbon nanotubes in 50% (vol/vol) methanol were added to the sample solution to extract analytes onto surface of carbon nanotubes because of their dramatic hydrophobicity. Carbon nanotubes in solution are deposited onto the bottom of tube with centrifugation. After removing the supernatant fluid, carbon nanotubes are suspended again with dispersant and pipetted directly onto the sample target of the MALDI-MS to perform a mass spectrometric analysis. It was demonstrated by analysis of a variety of small molecules that the resolution of peaks and the efficiency of desorption/ionization on the carbon nanotubes are better than those on the activated carbon. It is found that with the addition of glycerol and sucrose to the dispersant, the intensity, the ratio of signal to noise (S/N), and the resolution of peaks for analytes by mass spectrometry increased greatly. Compared with the previously reported method by depositing sample solution onto thin layer of carbon nanotubes, it is observed that the detection limit for analytes can be enhanced about 10 to 100 times due to solid-phase extraction of analytes in solution by carbon nanotubes. An acceptable result of simultaneously quantitative analysis of three analytes in solution has been achieved. The application in determining drugs spiked into urine has also been realized.

  11. Use of radioimmunoassay as a screen for antibiotics in confined animal feeding operations and confirmation by liquid chromatography/mass spectrometry

    Science.gov (United States)

    Meyer, M.T.; Bumgarner, J.E.; Varns, J.L.; Daughtridge, J.V.; Thurman, E.M.; Hostetler, K.A.

    2000-01-01

    Approximately one-half of the 50 000000 lb of antibiotics produced in the USA are used in agriculture. Because of the intensive use of antibiotics in the management of confined livestock operations, the potential exists for the transport of these compounds and their metabolites into our nation's water resources. A commercially available radioimmunoassay method, developed as a screen for tetracycline antibiotics in serum, urine, milk, and tissue, was adapted to analyze water samples at a detection level of approximately 1.0 ppb and a semiquantitative analytical range of 1-20 ppb. Liquid waste samples were obtained from 13 hog lagoons in three states and 52 surface- and ground-water samples were obtained primarily from areas associated with intensive swine and poultry production in seven states. These samples were screened for the tetracycline antibiotics by using the modified radioimmunoassay screening method. The radioimmunoassay tests yielded positive results for tetracycline antibiotics in samples from all 13 of the hog lagoons. Dilutions of 10-100-fold of the hog lagoon samples indicated that tetracycline antibiotic concentrations ranged from approximately 5 to several hundred parts per billion in liquid hog lagoon waste. Of the 52 surface- and ground-water samples collected all but two tested negative and these two samples contained tetracycline antibiotic concentrations less than 1 ppb. A new liquid chromatography/mass spectrometry method was used to confirm the radioimmunoassay results in 9 samples and also to identify the tetracycline antibiotics to which the radioimmunoassay test was responding. The new liquid chromatography/mass spectrometry method with online solid-phase extraction and a detection level of 0.5 ??g/l confirmed the presence of chlorotetracycline in the hog lagoon samples and in one of the surface-water samples. The concentrations calculated from the radioimmunoassay were a factor of 1-5 times less than those calculated by the liquid

  12. Antibody response to the lipopolysaccharide and protein antigens of Salmonella typhi during typhoid infection. I. Measurement of serum antibodies by radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Tsang, R S.W.; Chau, P Y; Lam, S K [Hong Kong Univ.; La Brooy, J T; Rowley, D [Adelaide Univ. (Australia)

    1981-12-01

    Serum antibody responses to the lipopolysaccharide and protein antigens of S. typhi in typhoid patients were studied using a solid-phase radioimmunoassay technique with /sup 125/I labelled anti-immunoglobulin antibody. Sera from 24 adult typhoid patients and 20 non-typhoid adult controls were compared. As a group, sera from typhoid patients showed increased IgA, IgG and IgM immunoglobulin levels and gave significantly higher anti-LPS and anti-protein antibody titres in all three major immunoglobulin classes than did non-typhoid controls. Levels of antibodies against LPS or protein in sera of typhoid patients were highly variable with a skew distribution. A good correlation was found between antibody titres to the LPS antigen and those to a protein antigen. No correlation, however, was found between the anti-LPS antibody titres measured by radioimmunoassay and the anti-O antibody titres measured by the Widal agglutination test. Titration of anti-LPS or anti-protein antibodies by radioimmunoassay was found to be more sensitive and specific than Widal test for the serological diagnosis of typhoid fever. The advantages of measuring antibody response by radioimmunoassay over conventional Widal test are discussed.

  13. Radioimmunoassay for 2,4-dichlorophenoxyacetic acid

    International Nuclear Information System (INIS)

    Knopp, D.; Dobberkau, H.J.; Nuhn, P.

    1985-01-01

    Antisera to 2,4-dichlorophenoxyacetic acid (2,4-D), a widely used herbicide, have been obtained from rabbits following immunization with various 2,4-D-protein conjugates. Employing [ 125 I] 2,4-D-tyramine as the radioligand for the antisera, very poor assay sensitivity was achieved because of a much higher affinity of the antibodies to the tracer. When using [6- 3 H] 2,4-D (specific radioactivity 465 GBq/mmol) a sensitive and specific radioimmunoassay (RIA) for 2,4-D could be developed, which allows determination directly in water, plasma and urine samples. Levels as low as approximately 100 pg (450 femtomoles) of 2,4-D can be detected. The antiserum is fairly specific for 2,4-D. Other related phenoxycarboxylic acids and dichlorophenol showed a cross-reactivity smaller than 10%. After a single administration of 2,4-D (0.91 mg/100 g body weight, orally) to rats, plasma and urine levels were determined at different times. Results correspond to those found in the literature, thus indicating the utility of the RIA. Further applications and limitations are discussed. (orig.)

  14. Radioimmunoassay of renin in human renal tissues

    International Nuclear Information System (INIS)

    Wowra, B.

    1981-01-01

    A method has been developed to quantitatively determine renin in human kidney tissue. The angiotensin I split off angiotensinogs by renin was radioimmunologically determined. The renin-renin substrate reaction rate followed a saturation kinetics, as it increased the larger the substrate content in the incubation medium until it acquired a maximum value; the reaction rate decreased with substrate concentrations over 40 mg/ml incubation medium. The discontinuance of the renin reaction after incubation by adding acid, boiling and neutralizing again, gave highest renin values. The RIA scattering was 8.3% for double determination of the same sample, for the determination in different RIA additions 7.0%. The detection limit was 20 pg angiotensin I. A direct comparison of radioimmunoassay and bioassay exhibited a very significant agreement of both methods, where the radioimmunologically measured renin values were on average four times larger than those obtained using biological technique. The definition of the so-called normal values for absolute and specific renin concentration in human kidney tissue enabled one to assess the renin values in various syndromes. (orig./MG) [de

  15. Radioimmunoassay of penicilloyl groups in biological fluids

    International Nuclear Information System (INIS)

    Wal, J-M.; Bories, G.

    1975-01-01

    Penicilloyl-protein conjugates may be formed in man or animals after therapeutic treatment but cannot be detected by the classical microbiological assay methods used for penicillin. Allergies have been noted in consumers of products coming from animals treated with penicillin (milk particularly). Although these compounds present a risk to public health, they passed unnoticed through hygienic food inspection. Therefore a specific and sensitive method was devised for the assay of these derivatives in biological fluids where they can be present in trace amounts. An iodine-125 labelled conjugate has been prepared. Already usable for the detection of antipenicilloyl antibodies in sera of penicillin allergic patients, it has been used for the development of a radioimmunoassay of penicilloyl groups. Assay is done directly on milk, urine and serum without previous extraction and with a detection limit of a few ppb. It permits a rapid, specific and easy to handle determination in the sera of hospital patients as well as in the inspection of animal products at the slaughter house and at the dairy

  16. A simple radioimmunoassay for plasma cortisol

    International Nuclear Information System (INIS)

    Seth, J.; Brown, L.M.

    1978-01-01

    A simple radioimmunoassay (RIA) for plasma cortisol is described which combines the advantages of (i) direct analysis of untreated plasma samples, (ii) use of solid-coupled anti-cortisol antibodies and (iii) use of a gamma-labelled radioligand. The reagents are relatively easily prepared and stable, and the analysis can be completed in 4 h. Inter-assay precision (C.V.) is 8-11%. Critical examination of specificity using high pressure liquid chromatography showed that 23-35% of the immunoassayable material in plasma was not cortisol. RIA results on samples collected under basal conditions were an average 40 nmol/l lower than fluorimetric results, while in insulin hypoglycaemia and synacthen (ACTH) stimulation tests, this difference increased to over 100 nmol/l. The RIA is technically more simple than fluorimetric, competitive-protein-binding, and many RIA methods, and can be used with advantage in the routine investigation of adrenocortical function. However, using the present antiserum, the RIA is not applicable to investigations on patients receiving metyrapone, nor in suspected cases of congenital adrenal hyperplasia. (Auth.)

  17. Steroid radioimmunoassays. The problems of blanks

    Energy Technology Data Exchange (ETDEWEB)

    Shinde, Y; Hacker, R R; Ntunde, B; Smith, V G [Guelph Univ., Ontario (Canada). Dept. of Animal and Poultry Science

    1981-06-01

    An estrogen radioimmunoassay was used to study the problem of blanks in steroid assays. Negligible binding (1.5 percent) in the non-antibody tubes prevailed throughout the study. The assay was validated using accepted procedures. Both water and solvent blanks had estrogen concentrations of 7-9 pg/tube. However, neither water nor solvent blanks showed a dose-related response, indicating that they were 'real' blanks. Exogenous estradiol, when added to water and solvent in quantities less than the estimated blank, was not quantitatively recovered. However, exogenous estradiol added to the water solvent in quantities greater than the blank estimate was quantitatively recovered. The sensitivity of the reference standard curve was 6-10 pg/tube, approximately the same as the blank estimate. These results indicated that the estimates of water and solvent blanks were measures of the assay sensitivity. In such circumstances, it is suggested that blank estimates should not be subtracted from sample values. If the blank estimates are high, attention should be directed towards improving the sensitivity of the assay.

  18. Solid-solid phase change thermal storage application to space-suit battery pack

    Science.gov (United States)

    Son, Chang H.; Morehouse, Jeffrey H.

    1989-01-01

    High cell temperatures are seen as the primary safety problem in the Li-BCX space battery. The exothermic heat from the chemical reactions could raise the temperature of the lithium electrode above the melting temperature. Also, high temperature causes the cell efficiency to decrease. Solid-solid phase-change materials were used as a thermal storage medium to lower this battery cell temperature by utilizing their phase-change (latent heat storage) characteristics. Solid-solid phase-change materials focused on in this study are neopentyl glycol and pentaglycerine. Because of their favorable phase-change characteristics, these materials appear appropriate for space-suit battery pack use. The results of testing various materials are reported as thermophysical property values, and the space-suit battery operating temperature is discussed in terms of these property results.

  19. The Effects of Solid Phase Additives on Sintering Properties of Alumina Bioceramic

    Institute of Scientific and Technical Information of China (English)

    WANG Xin-yu; LI Shi-pu; HE Jian-hua; JIANG Xin; LI Jian-hua

    2003-01-01

    In order to reduce the sintering temperature and improve the preparing conditions of alumina bioceramics,the Mg-Zr-Y composite solid phase additives were added into high purity Al2O3 micro-powder by chemical coprecipitation method.The powder was shaped under 200MPa cold isostatic pressure,and then the biscuits were sintered at 1600℃ under normal pressure.The sintered alumina materials were tested and the sintering mechanism was discussed.The results show that physical properties of the material were improved comparatively.The Mg-Zr-Y composite solid additives could promote the sintering of alumina bioceramics and the mechanism is solid phase sintering.

  20. A Facile, Choline Chloride/Urea Catalyzed Solid Phase Synthesis of Coumarins via Knoevenagel Condensation

    Directory of Open Access Journals (Sweden)

    Hosanagara N. Harishkumar

    2011-01-01

    Full Text Available The influence of choline chloride/urea ionic liquid in solid phase on the Knoevenagel condensation is demonstrated. The active methylene compounds such as meldrum’s acid, diethylmalonate, ethyl cyanoacetate, dimethylmalonate, were efficiently condensed with various salicylaldehydes in presence of choline chloride/urea ionic liquid without using any solvents or additional catalyst. The reaction is remarkably facile because of the air and water stability of the catalyst, and needs no special precautions. The reactions were completed within 1hr with excellent yields (95%. The products formed were sufficiently pure, and can be easily recovered. The use of ionic liquid choline chloride/urea in solid phase offered several significant advantages such as low cost, greater selectivity and easy isolation of products.

  1. Solid-Phase Synthesis of Smac Peptidomimetics Incorporating Triazoloprolines and Biarylalanines

    DEFF Research Database (Denmark)

    Le Quement, Sebastian T.; Ishoey, Mette; Petersen, Mette T.

    2011-01-01

    by deactivating proteolytic caspases. The Smac protein has an antagonistic effect on IAPs, thus providing structural clues for the synthesis of new pro-apoptotic compounds. Herein, we report a solid-phase approach for the synthesis of Smac-derived tetrapeptide libraries. On the basis of a common (N......-Me)AVPF sequence, peptides incorporating triazoloprolines and biarylalanines were synthesized by means of Cu(I)-catalyzed azide–alkyne cycloaddition and Pd-catalyzed Suzuki cross-coupling reactions. Solid-phase procedures were optimized to high efficiency, thus accessing all products in excellent crude purities...... and yields (both typically above 90%). The peptides were subjected to biological evaluation in a live/dead cellular assay which revealed that structural decorations on the AVPF sequence indeed are highly important for cytotoxicity toward HeLa cells....

  2. Solid-solid phase transitions in Fe nanowires induced by axial strain

    International Nuclear Information System (INIS)

    Sandoval, Luis; Urbassek, Herbert M

    2009-01-01

    By means of classical molecular-dynamics simulations we investigate the solid-solid phase transition from a bcc to a close-packed crystal structure in cylindrical iron nanowires, induced by axial strain. The interatomic potential employed has been shown to be capable of describing the martensite-austenite phase transition in iron. We study the stress versus strain curves for different temperatures and show that for a range of temperatures it is possible to induce a solid-solid phase transition by axial strain before the elasticity is lost; these transition temperatures are below the bulk transition temperature. The two phases have different (non-linear) elastic behavior: the bcc phase softens, while the close-packed phase stiffens with temperature. We also consider the reversibility of the transformation in the elastic regimes, and the role of the strain rate on the critical strain necessary for phase transition.

  3. Aqueous Microwave-Assisted Solid-Phase Synthesis Using Boc-Amino Acid Nanoparticles

    Directory of Open Access Journals (Sweden)

    Yoshinobu Fukumori

    2013-07-01

    Full Text Available We have previously developed water-based microwave (MW-assisted peptide synthesis using Fmoc-amino acid nanopaticles. It is an organic solvent-free, environmentally friendly method for peptide synthesis. Here we describe water-based MW-assisted solid-phase synthesis using Boc-amino acid nanoparticles. The microwave irradiation allowed rapid solid-phase reaction of nanoparticle reactants on the resin in water. We also demonstrated the syntheses of Leu-enkephalin, Tyr-Gly-Gly-Phe-Leu-OH, and difficult sequence model peptide, Val-Ala-Val-Ala-Gly-OH, using our water-based MW-assisted protocol with Boc-amino acid nanoparticles.

  4. Molecularly imprinted solid-phase extraction in the analysis of agrochemicals.

    Science.gov (United States)

    Yi, Ling-Xiao; Fang, Rou; Chen, Guan-Hua

    2013-08-01

    The molecular imprinting technique is a highly predeterminative recognition technology. Molecularly imprinted polymers (MIPs) can be applied to the cleanup and preconcentration of analytes as the selective adsorbent of solid-phase extraction (SPE). In recent years, a new type of SPE has formed, molecularly imprinted polymer solid-phase extraction (MISPE), and has been widely applied to the extraction of agrochemicals. In this review, the mechanism of the molecular imprinting technique and the methodology of MIP preparations are explained. The extraction modes of MISPE, including offline and online, are discussed, and the applications of MISPE in the analysis of agrochemicals such as herbicides, fungicides and insecticides are summarized. It is concluded that MISPE is a powerful tool to selectively isolate agrochemicals from real samples with higher extraction and cleanup efficiency than commercial SPE and that it has great potential for broad applications.

  5. Solid phase extraction and metabolic profiling of exudates from living copepods

    DEFF Research Database (Denmark)

    Selander, Erik; Heuschele, Jan; Nylund, Göran M.

    2016-01-01

    describe the development of a closed loop solid phase extraction setup that allows for extraction of exuded metabolites from live copepods. We captured exudates from male and female Temora longicornis and analyzed the content with high resolution LC-MS. Chemometric methods revealed 87 compounds...... that solid phase extraction in combination with metabolic profiling of exudates is a useful tool to develop our understanding of the chemical interplay between pelagic organisms....... Copepodamide G, known to induce defensive responses in phytoplankton, was among the ten compounds of highest relative abundance in both male and female extracts. The presence of copepodamide G shows that the method can be used to capture and analyze chemical signals from living source organisms. We conclude...

  6. Fifty years of solid-phase extraction in water analysis--historical development and overview.

    Science.gov (United States)

    Liska, I

    2000-07-14

    The use of an appropriate sample handling technique is a must in an analysis of organic micropollutants in water. The efforts to use a solid phase for the recovery of analytes from a water matrix prior to their detection have a long history. Since the first experimental trials using activated carbon filters that were performed 50 years ago, solid-phase extraction (SPE) has become an established sample preparation technique. The initial experimental applications of SPE resulted in widespread use of this technique in current water analysis and also to adoption of SPE into standardized analytical methods. During the decades of its evolution, chromatographers became aware of the advantages of SPE and, despite many innovations that appeared in the last decade, new SPE developments are still expected in the future. A brief overview of 50 years of the history of the use of SPE in organic trace analysis of water is given in presented paper.

  7. Solid-phase extraction NMR studies of chromatographic fractions of saponins from Quillaja saponaria.

    Science.gov (United States)

    Nyberg, Nils T; Baumann, Herbert; Kenne, Lennart

    2003-01-15

    The saponin mixture QH-B from the tree Quillaja saponaria var. Molina was fractionated by RP-HPLC in several steps. The fractions were analyzed by solid-phase extraction NMR (SPE-NMR), a technique combining the workup by solid-phase extraction with on-line coupling to an NMR flow probe. Together with MALDI-TOF mass spectrometry and comparison with chemical shifts of similar saponins, the structures of both major and minor components in QH-B could be obtained. The procedure described is a simple method to determine the structure of components in a complex mixture. The two major fractions of the mixture were found to contain at least 28 saponins, differing in the carbohydrate substructures. Eight of these have not previously been determined. The 28 saponins formed 14 equilibrium pairs by the migration of an O-acyl group between two adjacent positions on a fucosyl residue.

  8. Investigation of solid-phase hydrogenation of amino acids and peptides

    International Nuclear Information System (INIS)

    Zolotarev, Yu.A.; Myasoedov, N.F.; Zajtsev, D.A.; Lubnin, M.Yu.; Tatur, V.Yu.; Kozik, V.S.; Dorokhova, E.M.; Rozenberg, S.N.

    1990-01-01

    The possibility of synthesizing amino acids and peptides multiply labelled with tritium or deuterium by the method of solid-phase isotopic exchange with gaseous hydrogen isotopes was verified. Establishment of the isotopic hydrogen equilibrium between the gaseous phase and the solid phase formed by the amino acid molecules was found experimentally. The activation energy of the isotopic exchange is 13 kcal/mol. A mathematical model was set up for the isotopic exchange with a probable substitution of hydrogen atoms. Uniformly labelled amino acids were obtained in a high optical purity and with 80 to 90% hydrogen substitution by deuterium and tritium. Tritiated peptides were prepared in high yields at molar activities of 1.5 to 3.7 TBq/mmol. (author). 4 tabs

  9. New Approaches in Soil Organic Matter Fluorescence; A Solid Phase Fluorescence Approach

    Science.gov (United States)

    Bowman, M. M.; Sanclements, M.; McKnight, D. M.

    2017-12-01

    Fluorescence spectroscopy is a well-established technique to investigate the composition of organic matter in aquatic systems and is increasingly applied to soil organic matter (SOM). Current methods require that SOM be extracted into a liquid prior to analysis by fluorescence spectroscopy. Soil extractions introduce an additional layer of complexity as the composition of the organic matter dissolved into solution varies based upon the selected extractant. Water is one of the most commonly used extractant, but only extracts the water-soluble fraction of the SOM with the insoluble soil organic matter fluorescence remaining in the soil matrix. We propose the use of solid phase fluorescence on whole soils as a potential tool to look at the composition of organic matter without the extraction bias and gain a more complete understand of the potential for fluorescence as a tool in terrestrial studies. To date, the limited applications of solid phase fluorescence have ranged from food and agriculture to pharmaceutical with no clearly defined methods and limitations available. We are aware of no other studies that use solid phase fluorescence and thus no clear methods to look at SOM across a diverse set of soil types and ecosystems. With this new approach to fluorescence spectroscopy there are new challenges, such as blank correction, inner filter effect corrections, and sample preparation. This work outlines a novel method for analyzing soil organic matter using solid phase fluorescence across a wide range of soils collected from the National Ecological Observatory Network (NEON) eco-domains. This method has shown that organic matter content in soils must be diluted to 2% to reduce backscattering and oversaturation of the detector in forested soils. In mineral horizons (A) there is observed quenching of the humic-like organic matter, which is likely a result of organo-mineral complexation. Finally, we present preliminary comparisons between solid and liquid phase

  10. Visual monitoring of solid-phase extraction using chromogenic fluorous synthesis supports.

    Science.gov (United States)

    Blackburn, Christopher

    2012-03-12

    Reductive aminations and further transformations of an azo dye and fluorous tagged aldehyde are described. The intensely colored 2,4-dialkoxybenzyl protected amines undergo Fmoc-based peptide coupling, Suzuki reactions, and sulfonamide formation with product isolation facilitated by visual monitoring of fluorous solid phase extraction. Target compounds are released from the supports in high yields and purities by treatment with trifluoroacetic acid (TFA).

  11. HPLC WITH SOLID PHASE EXTRACTION FOR IDENTIFICATION AND DIAGNOSIS OF ORGANOPHOSPHOROUS POISONING IN GOATS

    Directory of Open Access Journals (Sweden)

    S. Manna

    2014-12-01

    Full Text Available High performance liquid chromatographic determination of organophosphorous compound has been done by reverse phase chromatography in goats. The goats were dying showing the symptoms of organophosphorous poisoning. The viscera and stomach contents sample were received from Project Co-Ordinator, Animal Disease Research Institute, Phulnakhara, Cuttack, Orissa. The analysis of samples by HPLC with UV detector after cleaning up in Solid Phase Extraction (SPE revealed presence of malathion that was later quantified.

  12. Integration of Solid-phase Extraction with Electrothermal Atomic Absorption Spectrometry for Determination of Trace Elements

    OpenAIRE

    NUKATSUKA, Isoshi; OHZEKI, Kunio

    2006-01-01

    An enrichment step in a sample treatment is essential for trace analysis to improve the sensitivity and to eliminate the matrix of the sample. Solid-phase extraction (SPE) is one of the widely used enrichment technique. Electrothermal atomic absorption spectrometry (ETAAS) is a well-established determination technique for trace elements. The integration of SPE with ETAAS leads to further improvement of sensitivity, an automation of the measurement and the economy in the sample size, amounts o...

  13. Optimization of the solid-phase microextraction method in the determination of Ixodes ricinus (L.) volatiles

    Czech Academy of Sciences Publication Activity Database

    Zahradníčková, Helena; Bouman, Edwin Arien Poul

    2006-01-01

    Roč. 29, č. 2 (2006), s. 236-241 ISSN 1615-9306 R&D Projects: GA ČR(CZ) GA206/04/0751 Institutional research plan: CEZ:AV0Z50070508; CEZ:AV0Z60220518 Keywords : GC/MS * Ixodes ricinus * solid-phase microextraction Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.535, year: 2006

  14. R. Bruce Merrifield and Solid-Phase Peptide Synthesis: A Historical Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, A R

    2007-12-04

    Bruce Merrifield, trained as a biochemist, had to address three major challenges related to the development and acceptance of solid-phase peptide synthesis (SPPS). The challenges were (1) to reduce the concept of peptide synthesis on a insoluble support to practice, (2) overcome the resistance of synthetic chemists to this novel approach, and (3) establish that a biochemist had the scientific credentials to effect the proposed revolutionary change in chemical synthesis. How these challenges were met is discussed in this article.

  15. Fast thermal annealing of implantation defects in silicon. Solid phase epitaxy and residual imperfection recovery

    International Nuclear Information System (INIS)

    Adekoya, O.A.

    1987-06-01

    Basic processes ruling the crystal reconstitution in solid phase during fast thermal annealing are studied; the role of electronic and thermodynamic effects at the interface is precised, following the implantations of a donor element (p + ), an acceptor element (B + ) and an intrinsic element (Ge + ). Then, after recrystallization, the electric role of residual point defects is shown together with the possibility of total recovery and an important electric activation of the doping [fr

  16. Solid phase carrier for radioimmuno analyses, as well as its manufacture and use

    International Nuclear Information System (INIS)

    Meriadec, B.; Roubertie, P.

    1979-01-01

    The solid phase carrier is in the form of a tablet containing freeze-dried protein-bonded gel, dicalcium phosphate and magnesium stearate. It is able to absorb 0.400 microlitre of an a solution containing antigen-antibody. When contacted with the solution, the tablet swells up and adapts to the shape of the column. The carrier is suitable for the TSH RIA test. (DG) [de

  17. Determination of organophosphorus pesticides using molecularly imprinted polymer solid phase extraction

    International Nuclear Information System (INIS)

    Mohd Marsin Sanagi; Syairah Salleh; Wan Aini Wan Ibrahim

    2011-01-01

    Molecularly imprinted polymer solid phase extraction (MIP-SPE) method has been developed for the determination of organophosphorus pesticides (OPPs) in water samples. The MIP was prepared by thermo-polymerization method using methacrylic acid (MAA) as functional monomer, ethylene glycol dimethacrylate (EGDMA) as crosslinker, acetonitrile as porogenic solvent and quinalphos as the template molecule. The three OPPs (diazinon, quinalphos and chloropyrifos) were selected as target analytes as they are widely used in agriculture sector. Various parameters affecting the extraction efficiency of the imprinted polymers have been evaluated to optimize the selective preconcentration of OPPs from aqueous samples. The characteristics of the MIP-SPE method were validated by high performance liquid chromatography (HPLC). The accuracy and selectivity of the MIP-SPE process developed were verified using non-imprinted polymer solid phase extraction (NIP-SPE) and a commercial C 18 -SPE was used for comparison. The recoveries of the target analytes obtained using the MIPs as the solid phase sorbent ranged from 83% to 98% (RSDs 1.05 - 1.98 %; n=3) for water sample. The developed MIP-SPE method demonstrates that it could be applied for the determination of OPPs in water samples. (author)

  18. Hypercrosslinked particles for the extraction of sweeteners using dispersive solid-phase extraction from environmental samples.

    Science.gov (United States)

    Lakade, Sameer S; Zhou, Qing; Li, Aimin; Borrull, Francesc; Fontanals, Núria; Marcé, Rosa M

    2018-04-01

    This work presents a new extraction material, namely, Q-100, based on hypercrosslinked magnetic particles, which was tested in dispersive solid-phase extraction for a group of sweeteners from environmental samples. The hypercrosslinked Q-100 magnetic particles had the advantage of suitable pore size distribution and high surface area, and showed good retention behavior toward sweeteners. Different dispersive solid-phase extraction parameters such as amount of magnetic particles or extraction time were optimized. Under optimum conditions, Q-100 showed suitable apparent recovery, ranging in the case of river water sample from 21 to 88% for all the sweeteners, except for alitame (12%). The validated method based on dispersive solid-phase extraction using Q-100 followed by liquid chromatography with tandem mass spectrometry provided good linearity and limits of quantification between 0.01 and 0.1 μg/L. The method was applied to analyze samples from river water and effluent wastewater, and four sweeteners (acesulfame, saccharin, cyclamate, and sucralose) were found in both types of sample. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Solid phase extraction for the speciation and preconcentration of inorganic selenium in water samples: a review.

    Science.gov (United States)

    Herrero Latorre, C; Barciela García, J; García Martín, S; Peña Crecente, R M

    2013-12-04

    Selenium is an essential element for the normal cellular function of living organisms. However, selenium is toxic at concentrations of only three to five times higher than the essential concentration. The inorganic forms (mainly selenite and selenate) present in environmental water generally exhibit higher toxicity (up to 40 times) than organic forms. Therefore, the determination of low levels of different inorganic selenium species in water is an analytical challenge. Solid-phase extraction has been used as a separation and/or preconcentration technique prior to the determination of selenium species due to the need for accurate measurements for Se species in water at extremely low levels. The present paper provides a critical review of the published methods for inorganic selenium speciation in water samples using solid phase extraction as a preconcentration procedure. On the basis of more than 75 references, the different speciation strategies used for this task have been highlighted and classified. The solid-phase extraction sorbents and the performance and analytical characteristics of the developed methods for Se speciation are also discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Determination of volatile compounds in grape distillates by solid-phase extraction and gas chromatography.

    Science.gov (United States)

    Lukić, Igor; Banović, Mara; Persurić, Dordano; Radeka, Sanja; Sladonja, Barbara

    2006-01-06

    Solid-phase extraction (SPE) procedure on octadecylsilica (C18) was developed for accumulation of volatile compounds from grape distillates. The procedure was optimised for final analysis by capillary gas chromatography. At mass concentrations in model solutions ranging from 0.1 to 50 mg/l solid-phase extraction recoveries of all analytes ranged from 69% for 2-phenylethanol to 102% for capric acid, with RSD values from 2 to 9%. SPE recoveries of internal standards to be added in the sample solution prior to extraction, higher alcohols 2-ethyl-1-hexanol and 1-undecanol, were 97 and 93%, respectively, with RSD values of 3%. Detection limits of analyzed compounds in model solutions ranged from 0.011 mg/l for isoamyl acetate to 0.037 mg/l for caproic acid. Method efficiency was tested in relation to acetic acid content, volume fraction of ethanol and possible matrix effects. A significant influence of matrix on SPE efficiency for geraniol, cis-2-hexen-1-ol and cis-3-hexen-1-ol was detected. For the same reason, 2-phenylethanol could not be determined by developed SPE method in samples of grape distillates. The developed solid-phase extraction method was successfully applied to determine the differences in volatile compound content in different grape distillates produced by the distillation of crushed, pressed and fermented grapes.