WorldWideScience

Sample records for direct ion pickup

  1. MAVEN Pickup Ion Constraints on Mars Neutral Escape

    Science.gov (United States)

    Rahmati, A.; Larson, D. E.; Cravens, T.; Lillis, R. J.; Dunn, P.; Halekas, J. S.; McFadden, J. P.; Mitchell, D. L.; Thiemann, E.; Connerney, J. E. P.; DiBraccio, G. A.; Espley, J. R.; Eparvier, F. G.

    2017-12-01

    Mars is currently losing its atmosphere mainly due to the escape of neutral hydrogen and oxygen. Directly measuring the rate of escaping neutrals is difficult, because the neutral density in the Mars exosphere is dominated, up to several Martian radii, by atoms that are gravitationally bound to the planet. Neutral atoms in the Martian exosphere, however, can get ionized, picked up, and accelerated by the solar wind motional electric field and energized to energies high enough for particle detectors to measure them. The MAVEN SEP instrument detects O+ pickup ions that are created at altitudes where the escaping part of the exosphere is dominant. Fluxes of these ions reflect neutral densities in the distant exosphere of Mars, allowing us to constrain neutral oxygen escape rates. The MAVEN SWIA and STATIC instruments measure pickup H+ and O+ created closer to Mars; comparisons of these data with models can be used to constrain exospheric hot O and thermal H densities and escape rates. In this work, pickup ion measurements from SEP, SWIA, and STATIC, taken during the first 3 Earth years of the MAVEN mission, are compared to the outputs of a pickup ion model to constrain the variability of neutral escape at Mars. The model is based on data from six MAVEN instruments, namely, MAG providing magnetic field used in calculating pickup ion trajectories, SWIA providing solar wind velocity as well as 3D pickup H+ and O+ spectra, SWEA providing solar wind electron spectrum used in electron impact ionization rate calculations, SEP providing pickup O+ spectra, STATIC providing mass resolved 3D pickup H+ and O+ spectra, and EUVM providing solar EUV spectra used in photoionization rate calculations. A variability of less than a factor of two is observed in hot oxygen escape rates, whereas thermal escape of hydrogen varies by an order of magnitude with Mars season. This hydrogen escape variability challenges our understanding of the H cycle at Mars, but is consistent with other

  2. Inner Source Pickup Ions Observed by Ulysses

    Science.gov (United States)

    Gloeckler, G.

    2016-12-01

    The existence of an inner source of pickup ions close to the Sun was proposed in order to explain the unexpected discovery of C+ in the high-speed polar solar wind. Here I report on detailed analyses of the composition and the radial and latitudinal variations of inner source pickup ions measured with the Solar Wind Ion Composition Spectrometer on Ulysses from 1991 to 1998, approaching and during solar minimum. We find that the C+ intensity drops off with radial distance R as R-1.53, peaks at mid latitudes and drops to its lowest value in the ecliptic. Not only was C+ observed, but also N+, O+, Ne+, Na+, Mg+, Ar+, S+, K+, CH+, NH+, OH+, H2O+, H3O+, MgH+, HCN+, C2H4+, SO+ and many other singly-charged heavy ions and molecular ions. The measured velocity distributions of inner source pickup C+ and O+ indicate that these inner source pickup ions are most likely produced by charge exchange, photoionization and electron impact ionization of neutrals close to the Sun (within 10 to 30 solar radii). Possible causes for the unexpected latitudinal variations and the neutral source(s) producing the inner source pickup ions as well as plausible production mechanisms for inner source pickup ions will be discussed.

  3. Pick-up ion energization at the termination shock

    Energy Technology Data Exchange (ETDEWEB)

    Gary, S Peter [Los Alamos National Laboratory; Winske, Dan [Los Alamos National Laboratory; Wu, Pin [BOSTON UNIV.; Schwadron, N A [BOSTON UNIV.

    2009-01-01

    One-dimensional hybrid simulations are used to investigate how pickup ions are energized at the perpendicular termination shock. Contrary to previous models based on pickup ion energy gain by repeated crossings of the shock front (shock surfing) or due to a reforming shock front, the present simulations show that pickup ion energy gain involves a gyro-phasedependent interaction with the inhomogeneous motional electric field at the shock. The process operates at all relative concentrations of pickup ion density.

  4. Survey of pickup ion signatures in the vicinity of Titan using CAPS/IMS

    Science.gov (United States)

    Regoli, L. H.; Coates, A. J.; Thomsen, M. F.; Jones, G. H.; Roussos, E.; Waite, J. H.; Krupp, N.; Cox, G.

    2016-09-01

    Pickup ion detection at Titan is challenging because ion cyclotron waves are rarely detected in the vicinity of the moon. In this work, signatures left by freshly produced pickup heavy ions (m/q ˜ 16 to m/q ˜ 28) as detected in the plasma data by the Cassini Plasma Spectrometer/Ion Mass Spectrometer (CAPS/IMS) instrument on board Cassini are analyzed. In order to discern whether these correspond to ions of exospheric origin, one of the flybys during which the reported signatures were observed is investigated in detail. For this purpose, ion composition data from time-of-flight measurements and test particle simulations to constrain the ions' origin are used. After being validated, the detection method is applied to all the flybys for which the CAPS/IMS instrument gathered valid data, constraining the region around the moon where the signatures are observed. The results reveal an escape region located in the anti-Saturn direction as expected from the nominal corotation electric field direction. These findings provide new constraints for the area of freshly produced pickup ion escape, giving an approximate escape rate of 3.3-2+3×1023 ions· s-1.

  5. Determination of interstellar pickup ion distributions in the solar wind with SOHO and Cluster

    Directory of Open Access Journals (Sweden)

    E. Möbius

    1996-05-01

    Full Text Available Over the last 10 years, the experimental basis for the study of the local interstellar medium has been substantially enhanced by the direct detection of interstellar pickup ions and of interstellar neutral helium within the heliosphere. Pickup ions can be studied for a wide range of interstellar species. However, currently the accuracy of the method to determine the parameters of the interstellar medium, namely neutral density, temperature and relative velocity, is hampered by two problems: (1 In most cases the crucial ionization rates are not available from simultaneous measurements and (2 the transport of the pickup ions in the interplanetary medium substantially modifies the measured spatial distribution of the ions. In this study we will discuss how the enhanced capabilities of the instrumentation on SOHO and Cluster in combination with ongoing efforts to model the pickup ion distributions will lead to a significant improvement over the coming years.

  6. Interaction of intersteller pick-up ions with the solar wind

    International Nuclear Information System (INIS)

    Mobius, E.; Klecker, B.; Hovestadt, D.; Scholer, M.

    1988-01-01

    The interaction of interstellar pick-up ions with the solar wind is studied by comparing a model for the velocity distribution function of pick-up ions with actual measurements of He + ions in the solar wind. The model includes the effects of pitch-angle diffusion due to interplanetary Alfven waves, adiabatic deceleration in the expanding solar wind and the radial variation of the source function. It is demonstrated that the scattering mean free path is in the range ≤0.1 AU and that energy diffusion can be neglected as compared with adiabatic deceleration. The effects of adiabatic focusing, of the radial variation of the neutral density and of an variation of the solar wind velocity with distance from the Sun are investigated. With the correct choice of these parameters the authors can model the measured energy spectra of the pick-up ions does not vary with the solar wind velocity and the direction of the interplanetary magnetic field for a given local neutral gas density and ionization rate. Therefore, the comparison of the model distributions with the measurements leads to a quantitative determination of the local interstellar gas density

  7. Oxygen Pickup Ions Measured by MAVEN Outside the Martian Bow Shock

    Science.gov (United States)

    Rahmati, A.; Cravens, T.; Larson, D. E.; Lillis, R. J.; Dunn, P.; Halekas, J. S.; Connerney, J. E. P.; Eparvier, F. G.; Thiemann, E.; Mitchell, D. L.; Jakosky, B. M.

    2015-12-01

    The MAVEN (Mars Atmosphere and Volatile EvolutioN) spacecraft entered orbit around Mars on September 21, 2014 and has since been detecting energetic oxygen pickup ions by its SEP (Solar Energetic Particles) and SWIA (Solar Wind Ion Analyzer) instruments. The oxygen pickup ions detected outside the Martian bowshock and in the upstream solar wind are associated with the extended hot oxygen exosphere of Mars, which is created mainly by the dissociative recombination of molecular oxygen ions with electrons in the ionosphere. We use analytic solutions to the equations of motion of pickup ions moving in the undisturbed upstream solar wind magnetic and motional electric fields and calculate the flux of oxygen pickup ions at the location of MAVEN. Our model calculates the ionization rate of oxygen atoms in the exosphere based on the hot oxygen densities predicted by Rahmati et al. (2014), and the sources of ionization include photo-ionization, charge exchange, and electron impact ionization. The photo-ionization frequency is calculated using the FISM (Flare Irradiance Spectral Model) solar flux model, based on MAVEN EUVM (Extreme Ultra-Violet Monitor) measurements. The frequency of charge exchange between a solar wind proton and an oxygen atom is calculated using MAVEN SWIA solar wind proton flux measurements, and the electron impact ionization frequency is calculated based on MAVEN SWEA (Solar Wind Electron Analyzer) solar wind electron flux measurements. The solar wind magnetic field used in the model is from the measurements taken by MAVEN MAG (magnetometer) in the upstream solar wind. The good agreement between our predicted pickup oxygen fluxes and the MAVEN SEP and SWIA measured ones confirms detection of oxygen pickup ions and these model-data comparisons can be used to constrain models of hot oxygen densities and photochemical escape flux.

  8. Probing the Martian Exosphere and Neutral Escape Using Pickup Ions Measured by MAVEN

    Science.gov (United States)

    Rahmati, A.; Larson, D. E.; Cravens, T.; Halekas, J. S.; Lillis, R. J.; McFadden, J. P.; Mitchell, D. L.; Thiemann, E.; Connerney, J. E. P.; Dunn, P.; DiBraccio, G. A.; Espley, J. R.; Eparvier, F. G.; Jakosky, B. M.

    2016-12-01

    Soon after the MAVEN (Mars Atmosphere and Volatile EvolutioN) spacecraft started orbiting Mars in September 2014, the SEP (Solar Energetic Particle), SWIA (Solar Wind Ion Analyzer), and STATIC (Supra-Thermal and Thermal Ion Composition) instruments onboard the spacecraft started detecting planetary pickup ions. SEP can measure energetic (>50 keV) oxygen pickup ions, the source of which is the extended hot oxygen exosphere of Mars. Model results show that these pickup ions originate from tens of Martian radii upstream of Mars and are energized by the solar wind motional electric field as they gyrate back towards Mars. SEP is blind to pickup hydrogen, as the low energy threshold for detection of hydrogen in SEP is 20 keV; well above the maximum pickup hydrogen energy, which is four times the solar wind proton energy. SWIA and STATIC, on the other hand, can detect both pickup oxygen and pickup hydrogen with energies below 30 keV and created closer to Mars. During the times when MAVEN is outside the Martian bow shock and in the upstream undisturbed solar wind, the solar wind velocity measured by SWIA and the solar wind (or interplanetary) magnetic field measured by the MAG (magnetometer) instrument can be used to model pickup oxygen and hydrogen fluxes near Mars. Solar wind flux measurements of the SWIA instrument are used in calculating charge-exchange frequencies, and data from the EUVM (Extreme Ultraviolet Monitor) and SWEA (Solar Wind Electron Analyzer) instruments are also used in calculating photo-ionization and electron impact frequencies of neutral species in the Martian exosphere. By comparing SEP, SWIA, and STATIC measured pickup ion fluxes with model results, the Martian thermal hydrogen and hot oxygen neutral densities can be probed outside the bow shock, which would place constraints on estimates of oxygen and hydrogen neutral escape rates. We will present model-data comparisons of pickup ions measured outside the Martian bow shock. Our analysis reveals an

  9. VOYAGER OBSERVATIONS OF MAGNETIC WAVES DUE TO NEWBORN INTERSTELLAR PICKUP IONS: 2–6 au

    International Nuclear Information System (INIS)

    Aggarwal, Poornima; Taylor, David K.; Smith, Charles W.; Joyce, Colin J.; Fisher, Meghan K.; Isenberg, Philip A.; Vasquez, Bernard J.; Schwadron, Nathan A.; Cannon, Bradford E.; Richardson, John D.

    2016-01-01

    We report observations by the Voyager 1 and 2 spacecraft of low-frequency magnetic waves excited by newborn interstellar pickup ions H + and He + during 1978–1979 when the spacecraft were in the range from 2 to 6.3 au. The waves have the expected association with the cyclotron frequency of the source ions, are left-hand polarized in the spacecraft frame, and have minimum variance directions that are quasi-parallel to the local mean magnetic field. There is one exception to this in that one wave event that is excited by pickup H + is right-hand polarized in the spacecraft frame, but similar exceptions have been reported by Cannon et al. and remain unexplained. We apply the theory of Lee and Ip that predicts the energy spectrum of the waves and then compare growth rates with turbulent cascade rates under the assumption that turbulence acts to destroy the enhanced wave activity and transport the associated energy to smaller scales where dissipation heats the background plasma. As with Cannon et al., we find that the ability to observe the waves depends on the ambient turbulence being weak when compared with growth rates, thereby allowing sustained wave growth. This analysis implies that the coupled processes of pitch-angle scattering and wave generation are continuously associated with newly ionized pickup ions, despite the fact that the waves themselves may not be directly observable. When waves are not observed, but wave excitation can be argued to be present, the wave energy is simply absorbed by the turbulence at a rate that prevents significant accumulation. In this way, the kinetic process of wave excitation by scattering of newborn ions continues to heat the plasma without producing observable wave energy. These findings support theoretical models that invoke efficient scattering of new pickup ions, leading to turbulent driving in the outer solar wind and in the IBEX ribbon beyond the heliopause.

  10. VOYAGER OBSERVATIONS OF MAGNETIC WAVES DUE TO NEWBORN INTERSTELLAR PICKUP IONS: 2–6 au

    Energy Technology Data Exchange (ETDEWEB)

    Aggarwal, Poornima [Electrical Engineering Department, Cooper Union, New York, NY 10003 (United States); Taylor, David K. [Rensselaer Polytechnic Institute, Troy, NH 12180 (United States); Smith, Charles W.; Joyce, Colin J.; Fisher, Meghan K.; Isenberg, Philip A.; Vasquez, Bernard J.; Schwadron, Nathan A. [Physics Department and Space Science Center, Institute for the Study of Earth, Oceans, and Space, University of New Hampshire, Durham, NH 03824 (United States); Cannon, Bradford E. [Physics Department, Florida State University, Tallahassee, FL 32306 (United States); Richardson, John D., E-mail: neema2000@gmail.com, E-mail: daves@orol.org, E-mail: Charles.Smith@unh.edu, E-mail: cjl46@wildcats.unh.edu, E-mail: mkl54@wildcats.unh.edu, E-mail: Phil.Isenberg@unh.edu, E-mail: Bernie.Vasquez@unh.edu, E-mail: N.Schwadron@unh.edu, E-mail: bc13h@my.fsu.edu, E-mail: jdr@space.mit.edu [Kavli Institute for Astrophysics and Space Research, Massachusetts Institute of Technology, 37-655, Cambridge, MA 02139 (United States)

    2016-05-10

    We report observations by the Voyager 1 and 2 spacecraft of low-frequency magnetic waves excited by newborn interstellar pickup ions H{sup +} and He{sup +} during 1978–1979 when the spacecraft were in the range from 2 to 6.3 au. The waves have the expected association with the cyclotron frequency of the source ions, are left-hand polarized in the spacecraft frame, and have minimum variance directions that are quasi-parallel to the local mean magnetic field. There is one exception to this in that one wave event that is excited by pickup H{sup +} is right-hand polarized in the spacecraft frame, but similar exceptions have been reported by Cannon et al. and remain unexplained. We apply the theory of Lee and Ip that predicts the energy spectrum of the waves and then compare growth rates with turbulent cascade rates under the assumption that turbulence acts to destroy the enhanced wave activity and transport the associated energy to smaller scales where dissipation heats the background plasma. As with Cannon et al., we find that the ability to observe the waves depends on the ambient turbulence being weak when compared with growth rates, thereby allowing sustained wave growth. This analysis implies that the coupled processes of pitch-angle scattering and wave generation are continuously associated with newly ionized pickup ions, despite the fact that the waves themselves may not be directly observable. When waves are not observed, but wave excitation can be argued to be present, the wave energy is simply absorbed by the turbulence at a rate that prevents significant accumulation. In this way, the kinetic process of wave excitation by scattering of newborn ions continues to heat the plasma without producing observable wave energy. These findings support theoretical models that invoke efficient scattering of new pickup ions, leading to turbulent driving in the outer solar wind and in the IBEX ribbon beyond the heliopause.

  11. Revisiting the theory of the evolution of pick-up ion distributions: magnetic or adiabatic cooling?

    Directory of Open Access Journals (Sweden)

    H. J. Fahr

    2007-01-01

    Full Text Available We study the phasespace behaviour of heliospheric pick-up ions after the time of their injection as newly created ions into the solar wind bulk flow from either charge exchange or photoionization of interplanetary neutral atoms. As interaction with the ambient MHD wave fields we allow for rapid pitch angle diffusion, but for the beginning of this paper we shall neglect the effect of quasilinear or nonlinear energy diffusion (Fermi-2 acceleration induced by counterflowing ambient waves. In the up-to-now literature connected with the convection of pick-up ions by the solar wind only adiabatic cooling of these ions is considered which in the solar wind frame takes care of filling the gap between the injection energy and energies of the thermal bulk of solar wind ions. Here we reinvestigate the basics of the theory behind this assumption of adiabatic pick-up ion reactions and correlated predictions derived from it. We then compare it with the new assumption of a pure magnetic cooling of pick-up ions simply resulting from their being convected in an interplanetary magnetic field which decreases in magnitude with increase of solar distance. We compare the results for pick-up ion distribution functions derived along both ways and can point out essential differences of observational and diagnostic relevance. Furthermore we then include stochastic acceleration processes by wave-particle interactions. As we can show, magnetic cooling in conjunction with diffusive acceleration by wave-particle interaction allows for an unbroken power law with the unique power index γ=−5 beginning from lowest velocities up to highest energy particles of about 100 KeV which just marginally can be in resonance with magnetoacoustic turbulences. Consequences for the resulting pick-up ion pressures are also analysed.

  12. Revisiting the theory of the evolution of pick-up ion distributions: magnetic or adiabatic cooling?

    Directory of Open Access Journals (Sweden)

    H. J. Fahr

    2008-01-01

    Full Text Available We study the phasespace behaviour of heliospheric pick-up ions after the time of their injection as newly created ions into the solar wind bulk flow from either charge exchange or photoionization of interplanetary neutral atoms. As interaction with the ambient MHD wave fields we allow for rapid pitch angle diffusion, but for the beginning of this paper we shall neglect the effect of quasilinear or nonlinear energy diffusion (Fermi-2 acceleration induced by counterflowing ambient waves. In the up-to-now literature connected with the convection of pick-up ions by the solar wind only adiabatic cooling of these ions is considered which in the solar wind frame takes care of filling the gap between the injection energy and energies of the thermal bulk of solar wind ions. Here we reinvestigate the basics of the theory behind this assumption of adiabatic pick-up ion reactions and correlated predictions derived from it. We then compare it with the new assumption of a pure magnetic cooling of pick-up ions simply resulting from their being convected in an interplanetary magnetic field which decreases in magnitude with increase of solar distance. We compare the results for pick-up ion distribution functions derived along both ways and can point out essential differences of observational and diagnostic relevance. Furthermore we then include stochastic acceleration processes by wave-particle interactions. As we can show, magnetic cooling in conjunction with diffusive acceleration by wave-particle interaction allows for an unbroken power law with the unique power index γ=−5 beginning from lowest velocities up to highest energy particles of about 100 KeV which just marginally can be in resonance with magnetoacoustic turbulences. Consequences for the resulting pick-up ion pressures are also analysed.

  13. Pickup Ions in the Plasma Environments of Mars, Comets, and Enceladus

    Science.gov (United States)

    Cravens, T.; Rahmati, A.; Sakai, S.; Madanian, H.; Larson, D. E.; Lillis, R. J.; Halekas, J. S.; Goldstein, R.; Burch, J. L.; Clark, G. B.; Jakosky, B. M.

    2015-12-01

    Ions created within a flowing plasma by ionization of neutrals respond to the electric and magnetic fields associated with the flow becoming what are called pick-up ions (PUI). PUI play an important role in many solar system plasma environments and affect the energy and momentum balance of the plasma flow. PUI have been observed during several recent space missions and PUI data will be compared and interpreted using models. Pick-up oxygen ions were observed in the solar wind upstream of Mars by the Solar Energetic Particle (SEP) and Solar Wind Ion Analyzer (SWIA) instruments on NASA's MAVEN (Mars Atmosphere and Volatile EvolutioN) spacecraft. The pick-up oxygen ions are created when atoms in the hot corona are ionized by solar radiation and charge exchange with solar wind protons. The ion fluxes measured by SEP can constrain the oxygen escape rate from Mars. PUI were also been detected at distances of 10 - 100 km from the nucleus of comet 67P/Churyumov- Gerasimenko (67P/CG) by plasma instruments (IES and ICA) onboard the Rosetta Orbiter when the comet was at 3 AU. The newly-born cometary ions are accelerated by the solar wind motional electric field but remain un-magnetized, as suggested by pre-encounter models (Rubin et al., 2014). The inner magnetosphere of Saturn and the water plume of the icy satellite Enceladus provide a third example of PUI. H2O+ ions created by ionization of neutral water producing ions that are picked-up by the co-rotating magnetospheric plasma flow. These ions then undergo a complex interaction with the plume gas including collisions that convert most H2O+ ions to H3O+, as measured by the Ion and Neutral Mass Spectrometer (INMS) onboard the Cassini spacecraft.

  14. Cometary pick-up ions observed near Giacobini-Zinner

    Science.gov (United States)

    Gloeckler, G.; Hovestadt, D.; Ipavich, F. M.; Scholer, M.; Klecker, B.

    1986-01-01

    The number and energy density of cometary water-group ions observed near Comet Giacobini-Zinner are derived using the rest-frame distribution functions. The data reveal that density profiles of inbound and outbound passes and their shape correlate with pick-up ion production model predictions. The lose rate and production rate of water-group cometary molecules calculated from predicted and measured density profiles are 2 x 10 to the -6th/sec and 2.6 x 10 to the 28th/sec respectively. The shapes of the distribution functions are examined to study the solar wind/cometary ions interaction process.

  15. Cassini CAPS Identification of Pickup Ion Compositions at Rhea

    Science.gov (United States)

    Desai, R. T.; Taylor, S. A.; Regoli, L. H.; Coates, A. J.; Nordheim, T. A.; Cordiner, M. A.; Teolis, B. D.; Thomsen, M. F.; Johnson, R. E.; Jones, G. H.; Cowee, M. M.; Waite, J. H.

    2018-02-01

    Saturn's largest icy moon, Rhea, hosts a tenuous surface-sputtered exosphere composed primarily of molecular oxygen and carbon dioxide. In this Letter, we examine Cassini Plasma Spectrometer velocity space distributions near Rhea and confirm that Cassini detected nongyrotropic fluxes of outflowing CO2+ during both the R1 and R1.5 encounters. Accounting for this nongyrotropy, we show that these possess comparable along-track densities of ˜2 × 10-3 cm-3. Negatively charged pickup ions, also detected during R1, are surprisingly shown as consistent with mass 26 ± 3 u which we suggest are carbon-based compounds, such as CN-, C2H-, C2-, or HCO-, sputtered from carbonaceous material on the moon's surface. The negative ions are calculated to possess along-track densities of ˜5 × 10-4 cm-3 and are suggested to derive from exogenic compounds, a finding consistent with the existence of Rhea's dynamic CO2 exosphere and surprisingly low O2 sputtering yields. These pickup ions provide important context for understanding the exospheric and surface ice composition of Rhea and of other icy moons which exhibit similar characteristics.

  16. Pick-Up Ion Instabilities at Planetary Magnetospheres

    Science.gov (United States)

    Strangeway, Robert J.; Sharber, James (Technical Monitor)

    2001-01-01

    This effort involved the analysis of low frequency waves as observed by the Galileo spacecraft near the Galilean moon, Io. Io is a significant source of material, especially SO2, and various products of dissociation, and further these atoms and molecules are readily ionized. The initial velocity of the ions is essentially that of the neutral species, i.e., the Keplerian velocity. The plasma, on the other hand is co-rotating, and there is a differential flow of the order 57 km/s between the plasma and the neutral particles. Thus pick-up ion instabilities are Rely to occur within the Jovian magnetosphere. Indeed, magnetometer observations from the Galileo spacecraft clearly show ion cyclotron waves that have been identified with a large variety of plasma species, such as O+, S++ (which has the same gyro-frequency as O+), S+, and SO2+. Typically, however, the dominant frequency is near the SO2+ gyro-frequency. The research effort was originally planned to be a team effort between Robert J. Strangeway as the Principal Investigator, and Debbie Huddleston, who was an Assistant Research Geophysicist at UCLA. Unfortunately, Dr. Huddleston took a position within Industry. The effort was therefore descoped, and Dr. Strangeway instead pursued a collaboration with Dr. Xochitl Blanco-Cano, of the Instituto de Geofisica, Universidad Nacional Autonoma de Mexico. This has proved to be a productive collaboration, with several papers and publications arising out of the effort. The magnetic field oscillations near lo generally fall into two types: ion cyclotron waves, with frequencies near an ion gyro-frequency, and lower frequency mirror-mode waves. The ion cyclotron waves are mainly transverse, and frequently propagate along the ambient magnetic field. The mirror-mode waves are compressional waves, and they have essentially zero frequency in the plasma rest frame. One of the purposes of our investigation is to understand what controls the types of wave modes that occur, since both

  17. Modeling and Observation of Interstellar He+ Pickup Ions in the Inner Heliosphere

    Science.gov (United States)

    Chen, Junhong

    Interstellar pickup ions constitute a charged particle population that originates from interstellar neutrals inside the heliosphere. They are produced by photoionization, charge exchange with solar wind ions, and electron impact ionization (EI). Once ionized, they are picked up by the interplanetary magnetic field (IMF) and rapidly swept outward with the solar wind. Typically, pickup ion distributions have been described in terms of a velocity distribution function that evolves through fast pitch angle scattering followed by adiabatic cooling during radial transport in the reference frame of the solar wind [e.g., Vasyliunas & Siscoe, 1976, VS76 hereafter]. In the VS76 model, the slope of the isotropic velocity distributions is controlled by the combination of the ionization rate and the cooling process. Thus far, for the cooling index that relates the slope of the velocity distribution to the radial transport and expansion of the pickup ions a constant value of 3/2 has been widely used. The implicit assumptions to arrive at this value are immediate PUI isotropization due to pitch angle scattering and solar wind expansion with the square of the distance from the Sun. Any experimental determination of the cooling index depends on the knowledge of the ionization rate and its spatial variation, as well as solar wind and interplanetary conditions. In this thesis, we study their influences on the PUI cooling index and separate them by making use of the two complementary helium PUI data sets from SWICS instrument on the ACE spacecraft, and PLASTIC instrument on STEREO spacecraft. We use the pickup ion observations from ACE SIWCS in the last solar cycle to determine the cooling index, and the possible effects of the electron impact ionization on the determination of the cooling index. With pickup ion observations from STEREO PLASTIC, we determine how solar wind expansion patterns affect the cooling index. We find that the cooling index varies substantially with solar

  18. Seasonal variation of Martian pick-up ions: Evidence of breathing exosphere

    Science.gov (United States)

    Yamauchi, M.; Hara, T.; Lundin, R.; Dubinin, E.; Fedorov, A.; Sauvaud, J.-A.; Frahm, R. A.; Ramstad, R.; Futaana, Y.; Holmstrom, M.; Barabash, S.

    2015-12-01

    The Mars Express (MEX) Ion Mass Analyser (IMA) found that the detection rate of the ring-like distribution of protons in the solar wind outside of the bow shock to be quite different between Mars orbital summer (around perihelion) and orbital winter (around aphelion) for four Martian years, while the north-south asymmetry is much smaller than the perihelion-aphelion difference. Further analyses using eight years of MEX/IMA solar wind data between 2005 and 2012 has revealed that the detection frequency of the pick-up ions originating from newly ionized exospheric hydrogen with certain flux strongly correlates with the Sun-Mars distance, which changes approximately every two years. Variation due to the solar cycle phase is not distinguishable partly because this effect is masked by the seasonal variation under the MEX capability of plasma measurements. This finding indicates that the variation in solar UV has a major effect on the formation of the pick-up ions, but this is not the only controlling factor.

  19. ENERGETIC NEUTRAL ATOMS: AN ADDITIONAL SOURCE FOR HELIOSPHERIC PICKUP IONS

    International Nuclear Information System (INIS)

    Bochsler, Peter; Moebius, Eberhard

    2010-01-01

    Recently, Schwadron and McComas discussed the possibility of inner source pickup particles originating from the ionization of energetic neutral atoms (ENAs), based on new data from the IBEX mission. This proposition has some interesting features, namely, it might be able to explain why inner source pickup ions (PUIs) have a composition resembling solar abundances and show no indication of overabundance of refractory elements, although this should be expected, if the conventional explanation of solar wind-dust interaction for the origin of this heliospheric component were correct. In this Letter, we explore further consequences for ENA-related PUIs and investigate their velocity distributions. We conclude that this model will not reproduce the observed velocity distributions of inner source PUIs and point out a substantial deviation in their composition. However, it seems likely that the ionization of ENAs as observed with IBEX could contribute a significant amount of heliospheric suprathermal tail ions. Some possible consequences of our investigation for heliospheric particle populations are briefly discussed.

  20. Sodium Pick-Up Ion Observations in the Solar Wind Upstream of Mercury

    Science.gov (United States)

    Jasinski, J. M.; Raines, J. M.; Slavin, J. A.; Regoli, L. R.; Murphy, N.

    2018-05-01

    We present the first observations of sodium pick-up ions upstream of Mercury’s magnetosphere. From these observations we infer properties of Mercury’s sodium exosphere and implications for the solar wind interaction with Mercury’s magnetosphere.

  1. Near Earth Inner-Source and Interstellar Pickup Ions Observed with the Hot Plasma Composition Analyzer of the Magnetospheric Multiscale Mission Mms-Hpca

    Science.gov (United States)

    Gomez, R. G.; Fuselier, S. A.; Mukherjee, J.; Gonzalez, C. A.

    2017-12-01

    Pickup ions found near the earth are generally picked up in the rest frame of the solar wind, and propagate radially outward from their point of origin. While propagating, they simultaneously gyrate about the magnetic field. Pickup ions come in two general populations; interstellar and inner source ions. Interstellar ions originate in the interstellar medium, enter the solar system in a neutral charge state, are gravitationally focused on the side of the sun opposite their arrival direction and, are ionized when they travel near the sun. Inner-source ions originate at a location within the solar system and between the sun and the observation point. Both pickup ion populations share similarities in composition and charge states, so measuring of their dynamics, using their velocity distribution functions, f(v)'s, is absolutely essential to distinguishing them, and to determining their spatial and temporal origins. Presented here will be the results of studies conducted with the four Hot Plasma Composition Analyzers of the Magnetospheric Multiscale Mission (MMS-HPCA). These instruments measure the full sky (4π steradians) distribution functions of near earth plasmas at a 10 second cadence in an energy-to-charge range 0.001-40 keV/e. The instruments are also capable of parsing this combined energy-solid angle phase space with 22.5° resolution polar angle, and 11.25° in azimuthal angle, allowing for clear measurement of the pitch angle scattering of the ions.

  2. Determining the Interstellar Wind Longitudinal Inflow Evolution Using Pickup Ions in the Helium Focusing Cone

    Science.gov (United States)

    Spitzer, S. A.; Gilbert, J. A.; Lepri, S. T.

    2017-12-01

    We propose to determine the longitudinal inflow direction of the local interstellar medium through the Heliosphere. This longitudinal inflow direction directly correlates to the longitudinal direction of the helium focusing cone with respect to the Sun. We can calculate this direction by finding the He+ pickup ion density peak as mass spectrometers such as ACE/SWICS, Wind/STICS, and Helios/Micrometeoroid Detector and Analyzer pass through the focusing cone. Mapping from the location of this density peak to the Sun, around which the helium is focused, will directly yield the desired longitudinal direction. We will find this direction for each year since the first measurements in the 1970s through the present and thereby analyze its evolution over time. This poster outlines our proposed method and initial results.

  3. Comparative pick-up ion distributions at Mars and Venus: Consequences for atmospheric deposition and escape

    Science.gov (United States)

    Curry, Shannon M.; Luhmann, Janet; Ma, Yingjuan; Liemohn, Michael; Dong, Chuanfei; Hara, Takuya

    2015-09-01

    Without the shielding of a substantial intrinsic dipole magnetic field, the atmospheres of Mars and Venus are particularly susceptible to similar atmospheric ion energization and scavenging processes. However, each planet has different attributes and external conditions controlling its high altitude planetary ion spatial and energy distributions. This paper describes analogous test particle simulations in background MHD fields that allow us to compare the properties and fates, precipitation or escape, of the mainly O+ atmospheric pick-up ions at Mars and Venus. The goal is to illustrate how atmospheric and planetary scales affect the upper atmospheres and space environments of our terrestrial planet neighbors. The results show the expected convection electric field-related hemispheric asymmetries in both precipitation and escape, where the degree of asymmetry at each planet is determined by the planetary scale and local interplanetary field strength. At Venus, the kinetic treatment of O+ reveals a strong nightside source of precipitation while Mars' crustal fields complicate the simple asymmetry in ion precipitation and drive a dayside source of precipitation. The pickup O+ escape pattern at both Venus and Mars exhibits low energy tailward escape, but Mars exhibits a prominent, high energy 'polar plume' feature in the hemisphere of the upward convection electric field while the Venus ion wake shows only a modest poleward concentration. The overall escape is larger at Venus than Mars (2.1 ×1025 and 4.3 ×1024 at solar maximum, respectively), but the efficiency (likelihood) of O+ escaping is 2-3 times higher at Mars. The consequences of these comparisons for pickup ion related atmospheric energy deposition, loss rates, and detection on spacecraft including PVO, VEX, MEX and MAVEN are considered. In particular, both O+ precipitation and escape show electric field controlled asymmetries that grow with energy, while the O+ fluxes and energy spectra at selected spatial

  4. On the Stability of Pick-up Ion Ring Distributions in the Outer Heliosheath

    Science.gov (United States)

    Summerlin, Errol J.; Viñas, Adolfo F.; Moore, Thomas E.; Christian, Eric R.; Cooper, John F.

    2014-10-01

    The "secondary energetic neutral atom (ENA)" hypothesis for the ribbon feature observed by the Interstellar Boundary Explorer (IBEX) posits that the neutral component of the solar wind continues beyond the heliopause and charge exchanges with interstellar ions in the Outer Heliosheath (OHS). This creates pick-up ions that gyrate about the draped interstellar magnetic field (ISMF) lines at pitch angles near 90° on the locus where the ISMF lies tangential to the heliopause and perpendicular to the heliocentric radial direction. This location closely coincides with the location of the ribbon feature according to the prevailing inferences of the ISMF orientation and draping. The locally gyrating ions undergo additional charge exchange and escape as free-flying neutral atoms, many of which travel back toward the inner solar system and are imaged by IBEX as a ribbon tracing out the locus described above. For this mechanism to succeed, the pick-up ions must diffuse in pitch angle slowly enough to permit secondary charge exchange before their pitch angle distribution substantially broadens away from 90°. Previous work using linear Vlasov dispersion analysis of parallel propagating waves has suggested that the ring distribution in the OHS is highly unstable, which, if true, would make the secondary ENA hypothesis incapable of rendering the observed ribbon. In this paper, we extend this earlier work to more realistic ring distribution functions. We find that, at the low densities necessary to produce the observed IBEX ribbon via the secondary ENA hypothesis, growth rates are highly sensitive to the temperature of the beam and that even very modest temperatures of the ring beam corresponding to beam widths of distributions necessary to produce the observed IBEX ENA flux via the secondary ENA hypothesis will be unstable to their own self-generated turbulence.

  5. Effects of time-dependent photoionization on interstellar pickup atoms

    International Nuclear Information System (INIS)

    Isenberg, P.A.; Lee, M.A.

    1995-01-01

    We present an analytical model for the density variations of interstellar pickup ions in the solar wind due to a time-dependent variation in the photoionization rate, our model predicts a pickup ion density enhancement lasting for a time of the order of the duration of the increase plus the solar wind convection time to the observation point. If the photoionization rate returns to its initial value, this enhancement is followed by a decreased pickup ion density resulting from a depleted interstellar neutral particle density. In the absence of further variations in the photoionization rate, the pickup ion density recovers on a time which scales as the radial position of the observation point divided by the inflow speed of the neutral particles. Gradual variations in the photoionization rate result in a pickup ion density which tends to track the ionization rate, though the density variations are smoothed and delayed in time due to the solar wind convection of ions picked up at points closer to the Sun. 27 refs., 4 figs

  6. Challenges in the determination of the interstellar flow longitude from the pickup ion cutoff

    Science.gov (United States)

    Taut, A.; Berger, L.; Möbius, E.; Drews, C.; Heidrich-Meisner, V.; Keilbach, D.; Lee, M. A.; Wimmer-Schweingruber, R. F.

    2018-03-01

    Context. The interstellar flow longitude corresponds to the Sun's direction of movement relative to the local interstellar medium. Thus, it constitutes a fundamental parameter for our understanding of the heliosphere and, in particular, its interaction with its surroundings, which is currently investigated by the Interstellar Boundary EXplorer (IBEX). One possibility to derive this parameter is based on pickup ions (PUIs) that are former neutral ions that have been ionized in the inner heliosphere. The neutrals enter the heliosphere as an interstellar wind from the direction of the Sun's movement against the partially ionized interstellar medium. PUIs carry information about the spatial variation of their neutral parent population (density and flow vector field) in their velocity distribution function. From the symmetry of the longitudinal flow velocity distribution, the interstellar flow longitude can be derived. Aim. The aim of this paper is to identify and eliminate systematic errors that are connected to this approach of measuring the interstellar flow longitude; we want to minimize any systematic influences on the result of this analysis and give a reasonable estimate for the uncertainty. Methods: We use He+ data measured by the PLAsma and SupraThermal Ion Composition (PLASTIC) sensor on the Solar TErrestrial RElations Observatory Ahead (STEREO A) spacecraft. We analyze a recent approach, identify sources of systematic errors, and propose solutions to eliminate them. Furthermore, a method is introduced to estimate the error associated with this approach. Additionally, we investigate how the selection of interplanetary magnetic field angles, which is closely connected to the pickup ion velocity distribution function, affects the result for the interstellar flow longitude. Results: We find that the revised analysis used to address part of the expected systematic effects obtains significantly different results than presented in the previous study. In particular

  7. Background and Pickup Ion Velocity Distribution Dynamics in Titan's Plasma Environment: 3D Hybrid Simulation and Comparison with CAPS T9 Observations

    Science.gov (United States)

    Lipatov, A. S.; Sittler, E. C., Jr.; Hartle, R. E.; Cooper, J. F.; Simpson, D. G.

    2011-01-01

    In this report we discuss the ion velocity distribution dynamics from the 3D hybrid simulation. In our model the background, pickup, and ionospheric ions are considered as a particles, whereas the electrons are described as a fluid. Inhomogeneous photoionization, electron-impact ionization and charge exchange are included in our model. We also take into account the collisions between the ions and neutrals. The current simulation shows that mass loading by pickup ions H(+); H2(+), CH4(+) and N2(+) is stronger than in the previous simulations when O+ ions are introduced into the background plasma. In our hybrid simulations we use Chamberlain profiles for the atmospheric components. We also include a simple ionosphere model with average mass M = 28 amu ions that were generated inside the ionosphere. The moon is considered as a weakly conducting body. Special attention will be paid to comparing the simulated pickup ion velocity distribution with CAPS T9 observations. Our simulation shows an asymmetry of the ion density distribution and the magnetic field, including the formation of the Alfve n wing-like structures. The simulation also shows that the ring-like velocity distribution for pickup ions relaxes to a Maxwellian core and a shell-like halo.

  8. A MEASUREMENT OF THE ADIABATIC COOLING INDEX FOR INTERSTELLAR HELIUM PICKUP IONS IN THE INNER HELIOSPHERE

    International Nuclear Information System (INIS)

    Saul, Lukas; Wurz, Peter; Kallenbach, Reinald

    2009-01-01

    Interstellar neutral gas enters the inner heliosphere where it is ionized and becomes the pickup ion population of the solar wind. It is often assumed that this population will subsequently cool adiabatically, like an expanding ideal gas due, to the divergent flow of the solar wind. Here, we report the first independent measure of the effective adiabatic cooling index in the inner heliosphere from SOHO CELIAS measurements of singly charged helium taken during times of perpendicular interplanetary magnetic field. We use a simple adiabatic transport model of interstellar pickup helium ions, valid for the upwind region of the inner heliosphere. The time averaged velocity spectrum of helium pickup ions measured by CELIAS/CTOF is fit to this model with a single free parameter which indicates an effective cooling rate with a power-law index of γ = 1.35 ± 0.2. While this average is consistent with the 'ideal-gas' assumption of γ = 1.5, the analysis indicates that such an assumption will not apply in general, and that due to observational constraints further measurements are necessary to constrain the cooling process. Implications are discussed for understanding the transport processes in the inner heliosphere and improving this measurement technique.

  9. On the Effects of Pickup Ion-driven Waves on the Diffusion Tensor of Low-energy Electrons in the Heliosphere

    Energy Technology Data Exchange (ETDEWEB)

    Engelbrecht, N. Eugene, E-mail: n.eugene.engelbrecht@gmail.com [Center for Space Research, North-West University, Potchefstroom, 2522 (South Africa)

    2017-11-01

    The effects of Alfvén cyclotron waves generated due to the formation in the outer heliosphere of pickup ions on the transport coefficients of low-energy electrons is investigated here. To this end, parallel mean free path (MFP) expressions are derived from quasilinear theory, employing the damping model of dynamical turbulence. These are then used as inputs for existing expressions for the perpendicular MFP and turbulence-reduced drift coefficient. Using outputs generated by a two-component turbulence transport model, the resulting diffusion coefficients are compared with those derived using a more typically assumed turbulence spectral form, which neglects the effects of pickup ion-generated waves. It is found that the inclusion of pickup ion effects greatly leads to considerable reductions in the parallel and perpendicular MFPs of 1–10 MeV electrons beyond ∼10 au, which are argued to have significant consequences for studies of the transport of these particles.

  10. On the stability of pick-up ion ring distributions in the outer heliosheath

    International Nuclear Information System (INIS)

    Summerlin, Errol J.; Viñas, Adolfo F.; Moore, Thomas E.; Christian, Eric R.; Cooper, John F.

    2014-01-01

    The 'secondary energetic neutral atom (ENA)' hypothesis for the ribbon feature observed by the Interstellar Boundary Explorer (IBEX) posits that the neutral component of the solar wind continues beyond the heliopause and charge exchanges with interstellar ions in the Outer Heliosheath (OHS). This creates pick-up ions that gyrate about the draped interstellar magnetic field (ISMF) lines at pitch angles near 90° on the locus where the ISMF lies tangential to the heliopause and perpendicular to the heliocentric radial direction. This location closely coincides with the location of the ribbon feature according to the prevailing inferences of the ISMF orientation and draping. The locally gyrating ions undergo additional charge exchange and escape as free-flying neutral atoms, many of which travel back toward the inner solar system and are imaged by IBEX as a ribbon tracing out the locus described above. For this mechanism to succeed, the pick-up ions must diffuse in pitch angle slowly enough to permit secondary charge exchange before their pitch angle distribution substantially broadens away from 90°. Previous work using linear Vlasov dispersion analysis of parallel propagating waves has suggested that the ring distribution in the OHS is highly unstable, which, if true, would make the secondary ENA hypothesis incapable of rendering the observed ribbon. In this paper, we extend this earlier work to more realistic ring distribution functions. We find that, at the low densities necessary to produce the observed IBEX ribbon via the secondary ENA hypothesis, growth rates are highly sensitive to the temperature of the beam and that even very modest temperatures of the ring beam corresponding to beam widths of <1° are sufficient to damp the self-generated waves associated with the ring beam. Thus, at least from the perspective of linear Vlasov dispersion analysis of parallel propagating waves, there is no reason to expect that the ring distributions necessary to

  11. Imprints from the solar cycle on the helium atom and helium pickup ion distributions

    Directory of Open Access Journals (Sweden)

    D. Rucinski

    Full Text Available Neutral interstellar helium atoms penetrate into the solar system almost unaffected by gas–plasma interactions in the heliospheric interface region, and thus can be considered as carriers of original information on the basic parameters (like density, temperature, bulk velocity of the Very Local Interstellar Medium (VLISM. Such information can nowadays be derived from analysis of data obtained from different experimental methods: in situ measurements of He atoms (Ulysses, observations of the solar backscattered He 584 A radiation (EUVE, in situ measurements of He + pickup ions (AMPTE, Ulysses, Wind, SOHO, ACE. In view of the current coordinated international ISSI campaign devoted to the study of the helium focusing cone structure and its evolution, we analyze expected variations of neutral He density, of He + pickup fluxes and of their phase space distributions at various phases of the solar activity cycle based on a realistic time-dependent modelling of the neutral helium and He + pickup ion distributions, which reflect solar cycle-induced variations of the photoionization rate. We show that the neutral helium density values are generally anticorrelated with the solar activity phase and in extreme cases (near the downwind axis the maximum-to-minimum density ratio may even exceed factors of ~ 3 at 1 AU. We also demonstrate that in the upwind hemisphere (at 1 AU and beyond the He + fluxes are correlated with the solar cycle activity, whereas on the downwind side the maximum of the expected flux up to distances of ~ 3 AU occurs around solar minimum epoch, and only further away does the correlation with solar activity become positive. Finally, we present the response of the phase space distribution spectra of He + pickup ions (in the solar wind frame for different epochs of the solar cycle and heliocentric distances from 1 to 5 AU covering the range of Ulysses, Wind and ACE observations.

    Key words. Solar physics, astrophysics and astronomy

  12. Imprints from the solar cycle on the helium atom and helium pickup ion distributions

    Directory of Open Access Journals (Sweden)

    D. Rucinski

    2003-06-01

    Full Text Available Neutral interstellar helium atoms penetrate into the solar system almost unaffected by gas–plasma interactions in the heliospheric interface region, and thus can be considered as carriers of original information on the basic parameters (like density, temperature, bulk velocity of the Very Local Interstellar Medium (VLISM. Such information can nowadays be derived from analysis of data obtained from different experimental methods: in situ measurements of He atoms (Ulysses, observations of the solar backscattered He 584 A radiation (EUVE, in situ measurements of He + pickup ions (AMPTE, Ulysses, Wind, SOHO, ACE. In view of the current coordinated international ISSI campaign devoted to the study of the helium focusing cone structure and its evolution, we analyze expected variations of neutral He density, of He + pickup fluxes and of their phase space distributions at various phases of the solar activity cycle based on a realistic time-dependent modelling of the neutral helium and He + pickup ion distributions, which reflect solar cycle-induced variations of the photoionization rate. We show that the neutral helium density values are generally anticorrelated with the solar activity phase and in extreme cases (near the downwind axis the maximum-to-minimum density ratio may even exceed factors of ~ 3 at 1 AU. We also demonstrate that in the upwind hemisphere (at 1 AU and beyond the He + fluxes are correlated with the solar cycle activity, whereas on the downwind side the maximum of the expected flux up to distances of ~ 3 AU occurs around solar minimum epoch, and only further away does the correlation with solar activity become positive. Finally, we present the response of the phase space distribution spectra of He + pickup ions (in the solar wind frame for different epochs of the solar cycle and heliocentric distances from 1 to 5 AU covering the range of Ulysses, Wind and ACE observations.Key words. Solar physics, astrophysics and astronomy

  13. Solar cycle variation of interstellar neutral He, Ne, O density and pick-up ions along the Earth's orbit

    OpenAIRE

    Sokół, Justyna M.; Bzowski, Maciej; Kubiak, Marzena A.; Möbius, Eberhard

    2016-01-01

    We simulated the modulation of the interstellar neutral (ISN) He, Ne, and O density and pick-up ion (PUI) production rate and count rate along the Earth's orbit over the solar cycle from 2002 to 2013 to verify if solar cycle-related effects may modify the inferred ecliptic longitude of the ISN inflow direction. We adopted the classical PUI model with isotropic distribution function and adiabatic cooling, modified by time- and heliolatitude-dependent ionization rates and non-zero injection spe...

  14. Heliospheric pick-up ions influencing thermodynamics and dynamics of the distant solar wind

    Directory of Open Access Journals (Sweden)

    H. J. Fahr

    2002-01-01

    Full Text Available Neutral interstellar H-atoms penetrate into the inner heliosphere and upon the event of ionization are converted into pick-up ions (PUIs. The magnetized solar wind flow incorporates these ions into the plasma bulk and enforces their co-motion. By nonlinear interactions with wind-entrained Alfvén waves, these ions are then processed in the comoving velocity space. The complete pick-up process is connected with forces acting back to the original solar wind ion flow, thereby decelerating and heating the solar wind plasma. As we show here, the resulting deceleration cannot be treated as a pure loading effect, but requires adequate consideration of the action of the pressure of PUI-scattered waves operating by the PUI pressure gradient. Hereby, it is important to take into proper account the stochastic acceleration which PUIs suffer from at their convection out of the inner heliosphere by quasi-linear interactions with MHD turbulences. Only then can the presently reported VOYAGER observations of solar wind decelerations and heatings in the outer heliosphere be understood in view of the most likely values of interstellar gas parameters, such as an H-atom density of 0.12 cm-3 . Solar wind protons (SWPs appear to be globally heated in their motion to larger solar distances. Ascribing the needed heat transfer to the action of suprathermal PUIs, which drive MHD waves that are partly absorbed by SWPs, in order to establish the observed SWP polytropy, we can obtain a quantitative expression for the solar wind proton pressure as a function of solar distance. This expression clearly shows the change from an adiabatic to a quasi-polytropic SWP behaviour with a decreasing polytropic index at increasing distances. This also allows one to calculate the average percentage of initial pick-up energy fed into the thermal proton energy. In a first order evaluation of this expression, we can estimate that about 10% of the initial PUI injection energy is eventually

  15. MgB2 magnetometer with directly coupled pick-up loop

    NARCIS (Netherlands)

    Portesi, C.; Mijatovic, D.; Veldhuis, Dick; Brinkman, Alexander; Monticone, E.; Gonnelli, R.S.

    2006-01-01

    magnetometer with a directly coupled pick-up loop. We used an all in situ technique for fabricating magnesium diboride films, which consists of the co-evaporation of B and Mg by means of an e-gun and a resistive heater respectively. Consequently, we realized the superconducting device, which

  16. Modelling of interplanetary pickup ion fluxes and relevance for LISM parameters

    International Nuclear Information System (INIS)

    Fahr, H.J.; Rucinski, D.

    1989-01-01

    It has been known for many years that neutral interstellar atoms enter the solar system from the upwind side and penetrate deep into the inner heliosphere. Helium atoms, in particular, advance towards very small solar distances before they are ionized and then again convected as He - pickup ions outwards with the solar wind. Since these ions were recently detected in space, we concentrate here on calculations of He + production rates and He + fluxes. It is shown that inside 1 a.u., the He - production is essentially determined both by solar e.u.v. photoionization and by electron impact ionization. We calculate He + production rates as a function of space coordinates, taking into account the core-halo structure of the energy distribution of solar wind electrons and their temperature distribution with distance according to relevant solar wind models. For this purpose, a newly developed program to compute He densities was used. In contrast to the production of H + , the He - production rates are found to be higher on the downwind axis than on the upwind axis by a factor of 5. We also determine partial and total He + ion fluxes as a function of solar distance and longitude. It is interesting to note that only the values for total fluxes agree well with the integrated He + fluxes measured by the SULEICA experiment aboard the AMPTE satellite. This indicates that pickup ions under the influence of the intrinsic MHD wave turbulence in the solar wind change their primary seed distribution function by rapid pitch-angle scattering and subsequent adiabatic cooling. To interpret the He + intensity profile along the orbit of the Earth in terms of LISM helium parameters, we point to the need to take into account carefully electron impact ionization in order to prevent misinterpretations. (author)

  17. Comet 73P Measurements of Solar Wind Interactions, Cometary Ion Pickup, and Spatial Distribution

    Science.gov (United States)

    Gilbert, J. A.; Lepri, S. T.; Rubin, M.; Combi, M. R.; Zurbuchen, T.

    2015-12-01

    Several fragments of Comet 73P/Schwassmann-Wachmann 3 passed near the Earth following a 2006 disintegration episode. Unique measurements regarding the charge state composition and the elemental abundances of both cometary and heliospheric plasma were made during this time by both the ACE/SWICS and Wind/STICS sensors. As the solar wind passed through the neutral cometary coma, it experienced charge exchange that was observed as an increase in the ratio of He+/He++. In addition, particles originating from fragments trailing the major cometary objects were ionized and picked up by the solar wind. The cometary material can be identified by the concentrations of water-group pickup ions having a mass-per-charge ratio of 16-18 amu/e, indicating that these are actively sublimating fragments. Here we present an analysis of cometary composition, spatial distribution, directionality, and heliospheric interactions with a focus on Helium, Carbon (C/O), and water-group ions.

  18. MgB2 magnetometer with a directly coupled pick-up loop

    Science.gov (United States)

    Portesi, C.; Mijatovic, D.; Veldhuis, D.; Brinkman, A.; Monticone, E.; Gonnelli, R. S.

    2006-05-01

    In this work, we show the results obtained in the fabrication and characterization of an MgB2 magnetometer with a directly coupled pick-up loop. We used an all in situ technique for fabricating magnesium diboride films, which consists of the co-evaporation of B and Mg by means of an e-gun and a resistive heater respectively. Consequently, we realized the superconducting device, which incorporates two nanobridges as weak links in a superconducting loop. The nanobridges were realized by focused ion beam milling; they were 240 nm wide and had a critical current density of 107 A cm-2. The magnetometer was characterized at different temperatures and also measurements of the noise levels have been performed. The device shows Josephson quantum interference up to 20 K and the calculated effective area at low temperatures was 0.24 mm2. The transport properties of the magnetometer allow determining fundamental materials properties of the MgB2 thin films, such as the penetration depth.

  19. A Data-driven Model of the Solar Wind, Interstellar Pickup Ions, and Turbulence Throughout the Interplanetary Space

    Science.gov (United States)

    Kim, T. K.; Kryukov, I.; Pogorelov, N. V.; Elliott, H. A.; Zank, G. P.

    2017-12-01

    The outer heliosphere is an interesting region characterized by the interaction between the solar wind and the interstellar neutral atoms. Having accomplished the mission to Pluto in 2015 and currently on the way to the Kuiper Belt, the New Horizons spacecraft is following the footsteps of the two Voyager spacecraft that previously explored this region lying roughly beyond 30 AU from the Sun. We model the three-dimensional, time-dependent solar wind plasma flow to the outer heliosphere using our own software Multi-Scale Fluid-Kinetic Simulation Suite (MS-FLUKSS), which, in addition to the thermal solar wind plasma, takes into account charge exchange of the solar wind protons with interstellar neutral atoms and treats nonthermal ions (i.e., pickup ions) born during this process as a separate fluid. Additionally, MS-FLUKSS allows us to model turbulence generated by pickup ions. We use MS-FLUKSS to investigate the evolution of plasma and turbulent fluctuations along the trajectory of the New Horizons spacecraft using plasma and turbulence parameters from OMNI data as time-dependent boundary conditions at 1 AU for the Reynolds-averaged MHD equations. We compare the model with in situ plasma observations by New Horizons, Voyager 2, and Ulysses. We also compare the model pickup proton parameters with those derived from the Ulysses-SWICS data.

  20. Beam-phase monitoring with non-destructive pickup

    International Nuclear Information System (INIS)

    Bogaty, J.; Clifft, B.E.

    1995-01-01

    An intensity and phase-sensitive capacitive pickup was installed at the entrance to the PII linac. This device is based on an extension of the design of the Beam Current Monitor developed as part of the ATLAS radiation safety system. The purpose of the pickup is to allow the arrival phase of the beam from the ECR source at the entrance to the PII linac to be set to a standard which reproduces previous tune conditions and establishes a standard. The new pickups and associated electronics demonstrated sensitivity well below 1 electrical nanoamp but can handle beam currents of many electrical microamps as well. In addition to phase information, beam current is also measured by the units thus providing a continuous, non-intercepting current readout as well. From the very first use of PII, we established a few open-quotes reference tunesclose quotes for the linac and scaled those tunes for any other beam desired. For such scaling to work properly, the velocity and phase of the beam from the ion source must be fixed and reproducible. In last year's FWP the new ATLAS Master Oscillator System was described. The new system has the ability of easily adjusting the beam arrival phase at the entrance to each of the major sections of the facility - PII, Booster, ATLAS. Our present techniques for establishing the beam arrival phase at the entrance of each of the linac sections are cumbersome and, sometimes, intellectually challenging. The installation of these capacitative pickups at the entrance to each of the linac sections will make the determination and setting of the beam arrival phase direct, simple, and dynamic. This should dramatically shorten our setup time for open-quotes old-tuneclose quotes configurations and increase useful operating hours. Permanent electronics for the PII entrance pickup is under construction

  1. MgB{sub 2} magnetometer with a directly coupled pick-up loop

    Energy Technology Data Exchange (ETDEWEB)

    Portesi, C [Istituto Elettrotecnico Nazionale Galileo Ferraris, Strada delle Cacce 91, I-10135 Turin (Italy); Mijatovic, D [Low Temperature Division and Mesa Research Institute, University of Twente, PO Box 217, 7500 AE Enschede (Netherlands); Veldhuis, D [Low Temperature Division and Mesa Research Institute, University of Twente, PO Box 217, 7500 AE Enschede (Netherlands); Brinkman, A [Low Temperature Division and Mesa Research Institute, University of Twente, PO Box 217, 7500 AE Enschede (Netherlands); Monticone, E [Istituto Elettrotecnico Nazionale Galileo Ferraris, Strada delle Cacce 91, I-10135 Turin (Italy); Gonnelli, R S [INFM, Dipartimento di Fisica, Politecnico di Torino, Corso Duca degli Abruzzi 24, I-10129 Turin (Italy)

    2006-05-15

    In this work, we show the results obtained in the fabrication and characterization of an MgB{sub 2} magnetometer with a directly coupled pick-up loop. We used an all in situ technique for fabricating magnesium diboride films, which consists of the co-evaporation of B and Mg by means of an e-gun and a resistive heater respectively. Consequently, we realized the superconducting device, which incorporates two nanobridges as weak links in a superconducting loop. The nanobridges were realized by focused ion beam milling; they were 240 nm wide and had a critical current density of 10{sup 7} A cm{sup -2}. The magnetometer was characterized at different temperatures and also measurements of the noise levels have been performed. The device shows Josephson quantum interference up to 20 K and the calculated effective area at low temperatures was 0.24 mm{sup 2}. The transport properties of the magnetometer allow determining fundamental materials properties of the MgB{sub 2} thin films, such as the penetration depth.

  2. Dynamic devices - pickups and kickers

    International Nuclear Information System (INIS)

    Lambertson, G.

    1986-08-01

    A given configuration of electrodes may be used either as a pickup or as a kicker; that duality is addressed. Some general relations between longitudinal and transverse effects and between the respones as pickup and as kicker are derived. Dynamic effects are seen to be entirely determined by the longitudinal electric fields in the direction of the beam current when the electrode is excited as a kicker. Response functions that serve as figures of merit are defined. The responses of specific examples of pickups and kickers are analyzed. An approach to the calculation of the transverse variation of coupling over the electrode aperture is preented

  3. Fully stripped heavy ion yield vs energy for Xe and Au ions

    International Nuclear Information System (INIS)

    Thieberger, P.; Wegner, H.E.; Alonzo, J.; Gould, H.; Anholt, R.E.; Meyerhof, W.E.

    1985-01-01

    The Bevalac is now capable of accelerating U-238 ions to approximately 1 GeV/amu and measurements have shown that fully stripped U-238 ions are produced with good yield at these energies. However, knowing the stripping yields at different energies for U-238 does not allow an accurate prediction for other, lower Z projectiles. Consequently, extensive stripping yield measurements were made for Au-197 and Xe-139 ions. In addition to the stripping measurements from the direct Bevalac beam, pickup measurements were also made with specially prepared bare, one electron, and two electron ions. Since many research groups are considering heavy ion storage rings and/or synchrotrons, the pickup cross section for bare ions is important to estimate beam lifetime in terms of the average machine vacuum. Since the Mylar target provides a pickup probability similar to air, a preliminary analysis of the Xe 54+ and U 92+ data are presented along with predictions for other ions ranging down to Fe 26+ . 11 refs., 3 figs., 1 tab

  4. Fully stripped heavy ion yield vs energy for Xe and Au ions

    Energy Technology Data Exchange (ETDEWEB)

    Thieberger, P.; Wegner, H.E.; Alonzo, J.; Gould, H.; Anholt, R.E.; Meyerhof, W.E.

    1985-01-01

    The Bevalac is now capable of accelerating U-238 ions to approximately 1 GeV/amu and measurements have shown that fully stripped U-238 ions are produced with good yield at these energies. However, knowing the stripping yields at different energies for U-238 does not allow an accurate prediction for other, lower Z projectiles. Consequently, extensive stripping yield measurements were made for Au-197 and Xe-139 ions. In addition to the stripping measurements from the direct Bevalac beam, pickup measurements were also made with specially prepared bare, one electron, and two electron ions. Since many research groups are considering heavy ion storage rings and/or synchrotrons, the pickup cross section for bare ions is important to estimate beam lifetime in terms of the average machine vacuum. Since the Mylar target provides a pickup probability similar to air, a preliminary analysis of the Xe/sup 54 +/ and U/sup 92 +/ data are presented along with predictions for other ions ranging down to Fe/sup 26 +/. 11 refs., 3 figs., 1 tab.

  5. Pickup protons at quasi-perpendicular shocks: full particle electrodynamic simulations

    Directory of Open Access Journals (Sweden)

    S. Matsukiyo

    2007-02-01

    Full Text Available We have performed 3 one-dimensional full particle electromagnetic simulations of a quasi-perpendicular shock with the same Alfvén Mach number MA~5, shock normal-magnetic field angle ΘBn=87° and ion and electron beta (particle to magnetic field pressure of 0.1. In the first run we used an ion to electron mass ratio close to the physical one (mi/me=1024. As expected from previous high mass ratio simulations the Modified Two-Stream instability develops in the foot of the shock, and the shock periodically reforms itself. We have then self-consistently included in the simulation 10% pickup protons distributed on a shell in velocity space as a third component. In a run with an unrealistically low mass ratios of 200 the shock still reforms itself; reformation is due to accumulation of specularly reflected particles at the upstream edge of the foot. In a third run including pickup protons we used a mass ratio of 1024. The shock reforms periodically as in the low mass ratio run with a somewhat smaller time constant. The specular reflection of pickup protons results in an increase of the shock potential some distance ahead of the shock foot and ramp. The minimum scale of the cross shock potential during reformation is about 7 electron inertial length λe. We do not find any pickup proton acceleration in the ramp or downstream of the shock beyond the energy which specularly reflected ions gain by the motional electric field of the solar wind during their upstream gyration.

  6. The Velocity Distribution Of Pickup He+ Measured at 0.3 AU by MESSENGER

    Science.gov (United States)

    Gershman, Daniel J.; Fisk, Lennard A.; Gloeckler, George; Raines, Jim M.; Slavin, James A.; Zurbuchen, Thomas H.; Solomon, Sean C.

    2014-06-01

    During its interplanetary trajectory in 2007-2009, the MErcury Surface, Space ENvrionment, GEochemistry, and Ranging (MESSENGER) spacecraft passed through the gravitational focusing cone for interstellar helium multiple times at a heliocentric distance R ≈ 0.3 AU. Observations of He+ interstellar pickup ions made by the Fast Imaging Plasma Spectrometer sensor on MESSENGER during these transits provide a glimpse into the structure of newly formed inner heliospheric pickup-ion distributions. This close to the Sun, these ions are picked up in a nearly radial interplanetary magnetic field. Compared with the near-Earth environment, pickup ions observed near 0.3 AU will not have had sufficient time to be energized substantially. Such an environment results in a nearly pristine velocity distribution function that should depend only on pickup-ion injection velocities (related to the interstellar gas), pitch-angle scattering, and cooling processes. From measured energy-per-charge spectra obtained during multiple spacecraft observational geometries, we have deduced the phase-space density of He+ as a function of magnetic pitch angle. Our measurements are most consistent with a distribution that decreases nearly monotonically with increasing pitch angle, rather than the more commonly modeled isotropic or hemispherically symmetric forms. These results imply that pitch-angle scattering of He+ may not be instantaneous, as is often assumed, and instead may reflect the velocity distribution of initially injected particles. In a slow solar wind stream, we find a parallel-scattering mean free path of λ || ~ 0.1 AU and a He+ production rate of ~0.05 m-3 s-1 within 0.3 AU.

  7. Resonant pickups for non-destructive single-particle detection in heavy-ion storage rings and first experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Sanjari, Mohammad Shahab

    2013-04-26

    Nuclear astrophysics studies on highly charged radionuclides benefit from accelerator facilities with storage rings, where exotic nuclides produced with small yields can be efficiently investigated. Currently there are two accelerator facilities capable of storing highly charged heavy ions, GSI in Darmstadt and IMP in Lanzhou. Non-destructive detection methods are often used for in-flight measurements based on frequency analysis. The sensitivity of such detection systems are of primary importance specially when number of stored ions is small. Furthermore, since the exotic nuclides of interest are as a rule short-lived, the detectors must be fast. One common form of such detectors are parallel plate SCHOTTKY monitors, on which particles induce a mirror charge at each passage. This method has been successfully used at ESR experimental storage ring of GSI since 1991. In this work we describe a new resonant SCHOTTKY pickup operating as a high sensitive cavity current monitor which was mounted and commissioned in the ESR early 2010. It was successfully used in several storage ring experiments. A very similar pickup was mounted in CSRe at IMP Lanzhou in 2011. First in-ring tests have been performed and new experimental results are pending. The spectral analysis of acquired signals by the new detector has enabled a broad range of new physics experiments. The theory of operation and first experimental results and future perspectives are presented in this thesis.

  8. Resonant pickups for non-destructive single-particle detection in heavy-ion storage rings and first experimental results

    International Nuclear Information System (INIS)

    Sanjari, Mohammad Shahab

    2013-01-01

    Nuclear astrophysics studies on highly charged radionuclides benefit from accelerator facilities with storage rings, where exotic nuclides produced with small yields can be efficiently investigated. Currently there are two accelerator facilities capable of storing highly charged heavy ions, GSI in Darmstadt and IMP in Lanzhou. Non-destructive detection methods are often used for in-flight measurements based on frequency analysis. The sensitivity of such detection systems are of primary importance specially when number of stored ions is small. Furthermore, since the exotic nuclides of interest are as a rule short-lived, the detectors must be fast. One common form of such detectors are parallel plate SCHOTTKY monitors, on which particles induce a mirror charge at each passage. This method has been successfully used at ESR experimental storage ring of GSI since 1991. In this work we describe a new resonant SCHOTTKY pickup operating as a high sensitive cavity current monitor which was mounted and commissioned in the ESR early 2010. It was successfully used in several storage ring experiments. A very similar pickup was mounted in CSRe at IMP Lanzhou in 2011. First in-ring tests have been performed and new experimental results are pending. The spectral analysis of acquired signals by the new detector has enabled a broad range of new physics experiments. The theory of operation and first experimental results and future perspectives are presented in this thesis.

  9. Ulysses observations of magnetic waves due to newborn interstellar pickup ions. I. New observations and linear analysis

    Energy Technology Data Exchange (ETDEWEB)

    Cannon, Bradford E. [Physics Department, Florida State University, Tallahassee, FL (United States); Smith, Charles W.; Isenberg, Philip A.; Vasquez, Bernard J. [Physics Department and Space Science Center, Institute for the Study of Earth, Oceans, and Space, University of New Hampshire, Durham, NH (United States); Murphy, Neil [Jet Propulsion Laboratory, Mail Stop 180-600, 4800 Oak Grove Drive, Pasadena, CA (United States); Nuno, Raquel G., E-mail: bc13h@my.fsu.edu, E-mail: Charles.Smith@unh.edu, E-mail: Phil.Isenberg@unh.edu, E-mail: Bernie.Vasquez@unh.edu, E-mail: Neil.Murphy@jpl.nasa.gov, E-mail: raquel.nuno@asu.edu [School of Earth and Space Exploration, Arizona State University, Tempe, AZ (United States)

    2014-04-01

    We have examined Ulysses magnetic field data using dynamic spectrogram techniques that compute wave amplitude, polarization, and direction of propagation over a broad range of frequencies and time. Events were identified that showed a strong polarization signature and an enhancement of power above the local proton gyrofrequency. We perform a statistical study of 502 wave events in an effort to determine when, where, and why they are observed. Most notably, we find that waves arising from newborn interstellar pickup ions are relatively rare and difficult to find. The quantities normally employed in theories of wave growth are neutral atom density and quantities related to their ionization and the subsequent dynamics such as wind speed, solar wind flux, and magnetic field orientation. We find the observations of waves to be largely uncorrelated to these quantities except for mean field direction where quasi-radial magnetic fields are favored and solar wind proton flux where wave observations appear to be favored by low flux conditions which runs contrary to theoretical expectations of wave generation. It would appear that an explanation based on source physics and instability growth rates alone is not adequate to account for the times when these waves are seen.

  10. Pickup protons at quasi-perpendicular shocks: full particle electrodynamic simulations

    Directory of Open Access Journals (Sweden)

    S. Matsukiyo

    2007-02-01

    Full Text Available We have performed 3 one-dimensional full particle electromagnetic simulations of a quasi-perpendicular shock with the same Alfvén Mach number MA~5, shock normal-magnetic field angle ΘBn=87° and ion and electron beta (particle to magnetic field pressure of 0.1. In the first run we used an ion to electron mass ratio close to the physical one (mi/me=1024. As expected from previous high mass ratio simulations the Modified Two-Stream instability develops in the foot of the shock, and the shock periodically reforms itself. We have then self-consistently included in the simulation 10% pickup protons distributed on a shell in velocity space as a third component. In a run with an unrealistically low mass ratios of 200 the shock still reforms itself; reformation is due to accumulation of specularly reflected particles at the upstream edge of the foot. In a third run including pickup protons we used a mass ratio of 1024. The shock reforms periodically as in the low mass ratio run with a somewhat smaller time constant. The specular reflection of pickup protons results in an increase of the shock potential some distance ahead of the shock foot and ramp. The minimum scale of the cross shock potential during reformation is about 7 electron inertial length λe. We do not find any pickup proton acceleration in the ramp or downstream of the shock beyond the energy which specularly reflected ions gain by the motional electric field of the solar wind during their upstream gyration.

  11. Dayside pickup oxygen ion precipitation at Venus and Mars: Spatial distributions, energy deposition and consequences

    International Nuclear Information System (INIS)

    Luhmann, J.G.; Kozyra, J.U.

    1991-01-01

    The fluxes and energy spectra of picked-up planetary O + ions incident on the dayside atmospheres of Venus and Mars are calculated using the neutral exposure models of Nagy and Cravens (1988) and the Spreiter and Stahara (1980) gasdynamic model of the magnetosheath electric and magnetic field. Cold (∼10 eV) O + ions are launched from hemispherical grids of starting points covering the daysides of the planets and their trajectories are followed until they either impact the dayside obstacle or cross the terminator plane. The impacting, or precipitating, ion fluxes are weighted according to the altitude of the hemispherical starting point grid in a manner consistent with the exosphere density models and the local photoion production rate. Maps of precipitating ion number flux and energy flux show the asymmetrical distribution of dayside energy deposition expected from this source which is unique to the weakly magnetized planets. Although the associated heating of the atmosphere and ionsphere is found to be negligible compared to that from the usual sources, backscattered or sputtered neutral oxygen atoms are produced at energies exceeding that needed for escape from the gravitational fields of both planets. These neutral winds, driven by pickup ion precipitation, represent a possibly significant loss of atmospheric constituents over the age of the solar system

  12. On ion injection at quasiparallel shocks

    International Nuclear Information System (INIS)

    Scholer, M.; Kucharek, H.; Kato, C.

    2002-01-01

    A large number of numerical experiments has been performed in order to study the interaction of interstellar pickup protons and helium ions with quasiparallel collisionless shocks. The shocks are modeled by a one-dimensional hybrid simulation method which treats the ions as macroparticles and the electrons as a massless fluid. Solar wind alpha particles and pickup protons are included self-consistently. In addition, the particle splitting method is used for the solar wind ions so that the distribution function can be followed over more than 10 orders of magnitude. A large part of the pickup ion distribution is reflected; the reflection efficiency is very high, and can reach in cases where the pickup ion density is low as much as 50%-60%. The reflection efficiency is almost independent of magnetic field-shock normal angle. This indicates that magnetic mirroring is unimportant and does not lead to larger reflection efficiencies. The reflection efficiency of pickup protons rapidly decreases when the pickup ion density exceeds a few percent of the solar wind density. An addition of 25% pickup protons decreases the reflection coefficient for these ions to ∼10%. This represents the fact that a quasiparallel shock cannot be considered as being uncoupled from the upstream region: at high additions of pickup ions the shock structure is changed in such a way as to reflect less pickup ions. The intensity of diffuse ions upstream of a quasiparallel shock does not depend on the temperature of the core distribution. Within the framework of the present model even solar wind distributions with a hard power law tail do not produce higher intensities of diffuse ions. It is argued that this can be understood by the fact that the intrinsic self-consistency between the processes in the upstream region and at the shock transition determines the injection and reflection properties of the core solar wind distribution

  13. INTERSTELLAR PICKUP ION PRODUCTION IN THE GLOBAL HELIOSPHERE AND HELIOSHEATH

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Y.; Florinski, V.; Guo, X., E-mail: yw0009@uah.edu [Center for Space Plasma and Aeronomic Research, University of Alabama in Huntsville, Huntsville, AL 35805 (United States)

    2016-11-20

    Interstellar pickup ions (PUIs) play a significant part in mediating the solar wind (SW) interaction with the interstellar medium. In this paper, we examine the details of spatial variation of the PUI velocity distribution function (VDF) in the SW by solving the PUI transport equation. We assume the PUI distribution is isotropic resulting from strong pitch-angle scattering by wave–particle interaction. A three-dimensional model combining the MHD treatment of the background SW and neutrals with a kinetic treatment of PUIs throughout the heliosphere and the surrounding local interstellar medium has been developed. The model generates PUI power-law tails via second-order Fermi process. We analyze how PUIs transform across the heliospheric termination shock and obtain the PUI phase space distribution in the inner heliosheath including continuing velocity diffusion. Our simulated PUI spectra are compared with observations made by New Horizons , Ulysses , Voyager 1, 2 , and Cassini , and a satisfactory agreement is demonstrated. Some specific features in the observations, for example, a cutoff of PUI VDF at v = V {sub SW} and a f ∝ v {sup -5} tail in the reference frame of the SW, are well represented by the model.

  14. Detection of interstellar pick-up hydrogen in the solar system

    Science.gov (United States)

    Gloeckler, G.; Geiss, J.; Balsiger, H.; Fisk, L. A.; Galvin, A. B.; Ipavich, F. M.; Ogilvie, K. W.; Von Steiger, R.; Wilken, B.

    1993-01-01

    Interstellar hydrogen ionized primarily by the solar wind has been detected by the Solar Wind Ion Composition Spectrometer instrument on the Ulysses spacecraft at a distance of 4.8 AUs from the sun. This 'pick-up' hydrogen is identified by its distinct velocity distribution function, which drops abruptly at twice the local solar wind speed. From the measured fluxes of pick-up protons and singly charged helium, the number densities of neutral hydrogen and helium in the distant regions of the solar system are estimated to be 0.077 +/- 0.015 and 0.013 +/- 0.003 per cu cm, respectively.

  15. Solar cycle variation of interstellar neutral He, Ne, O density and pick-up ions along the Earth's orbit

    Science.gov (United States)

    Sokół, Justyna M.; Bzowski, Maciej; Kubiak, Marzena A.; Möbius, Eberhard

    2016-06-01

    We simulated the modulation of the interstellar neutral (ISN) He, Ne, and O density and pick-up ion (PUI) production rate and count rate along the Earth's orbit over the solar cycle (SC) from 2002 to 2013 to verify if SC-related effects may modify the inferred ecliptic longitude of the ISN inflow direction. We adopted the classical PUI model with isotropic distribution function and adiabatic cooling, modified by time- and heliolatitude-dependent ionization rates and non-zero injection speed of PUIs. We found that the ionization losses have a noticeable effect on the derivation of the ISN inflow longitude based on the Gaussian fit to the crescent and cone peak locations. We conclude that the non-zero radial velocity of the ISN flow and the energy range of the PUI distribution function that is accumulated are of importance for a precise reproduction of the PUI count rate along the Earth orbit. However, the temporal and latitudinal variations of the ionization in the heliosphere, and particularly their variation on the SC time-scale, may significantly modify the shape of PUI cone and crescent and also their peak positions from year to year and thus bias by a few degrees the derived longitude of the ISN gas inflow direction.

  16. Acoustic emission pickup essentially for waveguide

    International Nuclear Information System (INIS)

    Asty, Michel; Saglio, Robert.

    1979-01-01

    Lambda wave length acoustic emission pickup comprising two juxtaposed piezoelectric capsules of equal lambda/2 thickness and with opposite polarization, separated by an electrically insulating foil, the two opposite sides of the capsules being earthed. The electric signal resulting from the acoustic emission is picked up on the two sides facing both sides of the insulating foil and the assembly of the two piezoelectric capsules is mounted on a base insulating it from the structure on which the acoustic emission is being listened to. Application of this pickup to the surveillance of defects in the steel vessels of nuclear reactors, characterized in that it is placed at the end of a metal ultrasonic wave guide the other end of which is welded directly to the vessel [fr

  17. Observations of Low-Frequency Magnetic Waves due to Newborn Interstellar Pickup Ions Using ACE, Ulysses, and Voyager Data

    Science.gov (United States)

    Smith, Charles W.; Aggarwal, Poornima; Argall, Matthew R.; Burlaga, Leonard F.; Bzowski, Maciej; Cannon, Bradford E.; Gary, S. Peter; Fisher, Meghan K.; Gilbert, Jason A.; Hollick, Sophia J.; Isenberg, Philip A.; Joyce, Colin J.; Murphy, Neil; Nuno, Raquel G.; Pine, Zackary B.; Richardson, John D.; Schwadron, Nathan A.; Skoug, Ruth M.; Sokół, Justyna M.; Taylor, David K.; Vasquez, Bernard J.

    2017-09-01

    Wave excitation by newborn interstellar pickup ions (PUIs) plays a significant role in theories that attempt to describe IBEX and Voyager observations in the solar wind and heliosheath. The same dynamic processes can be far-reaching and extend into the inner heliosphere to at least 1AU and likely to smaller heliocentric distances. While the high-resolution magnetic field measurements required to study these waves are not yet available in the heliosheath, we have studied a range of available observations and found evidence of waves due to interstellar PUIs using ACE (1998-2015 at 1 AU), Ulysses (1996-2006 at 2 to 5 AU, high and low latitudes) and Voyager (1978-1979 and 2 to 6 AU) observations. Efforts to extend the Voyager observations to 35 AU are ongoing. We have examined these data sets and report on observations of low-frequency waves that result from newborn interstellar pickup H+ and He+ ions. Although not as common as theory originally predicted, we presently have identified 524 independent occurrences. Our conclusion from studying these waves is that they are seen only when the ambient turbulence is sufficiently weak. The instability that generates these waves requires a slow accumulation of wave energy over several to tens of hours to achieve observable wave amplitudes. In regions where the turbulence is moderate to strong, the turbulence absorbs the wave energy before it can reach observable levels and transports the energy to the dissipation scales where it heats the background thermal particles. Only intervals with the weakest turbulence will permit energy accumulation over this time scale. These conditions are most often, but not exclusively, achieved in solar wind rarefaction regions.

  18. Pickup Ion Dynamics in the Outer Heliosheath Associated with the Growth of Kelvin-Helmholtz Instability at the Heliopause

    Science.gov (United States)

    Tsubouchi, K.

    2017-12-01

    A discovery of "IBEX ribbon", localized bright emission of energetic neutral atoms, has brought new insights into the plasma environment of its source region beyond the heliosphere. It has been basically established that its geometrical property is associated with the local interstellar magnetic field draped on the heliopause, and pickup ions (PUIs) in the outer heliosheath (OHS) must be its primary source particles. Understanding the PUI dynamics in OHS more in detail is our motivation for this study. We performed two-dimensional hybrid simulations to evaluate the response of PUIs to the structural variation in the heliosheath. We assumed the simulation system such that the background plasma is hot solar wind in the inner heliosheath and cold interstellar plasma in OHS, and the directions of these flows are tangential to the heliopause. Such a situation leads to the growth of Kelvin-Helmholtz instability (KHI), where the plasma mixing and turbulence excitation takes place. We identified that non-stationarity and non-uniformity emerges in the PUI density structure in a specific energy range as KHI process advances. Relevance of these results to the expected observation like IBEX ribbon will be discussed.

  19. AA, stochastic precooling pickup

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    The freshly injected antiprotons were subjected to fast stochastic "precooling". In this picture of a precooling pickup, the injection orbit is to the left, the stack orbit to the far right. After several seconds of precooling with the system's kickers (in momentum and in the vertical plane), the precooled antiprotons were transferred, by means of RF, to the stack tail, where they were subjected to further stochastic cooling in momentum and in both transverse planes, until they ended up, deeply cooled, in the stack core. During precooling, a shutter near the central orbit shielded the pickups from the signals emanating from the stack-core, whilst the stack-core was shielded from the violent action of the precooling kickers by a shutter on these. All shutters were opened briefly during transfer of the precooled antiprotons to the stack tail. Here, the shutter is not yet mounted. Precooling pickups and kickers had the same design, except that the kickers had cooling circuits and the pickups had none. Peering th...

  20. Ion heating and energy partition at the heliospheric termination shock: hybrid simulations and analytical model

    Energy Technology Data Exchange (ETDEWEB)

    Gary, S Peter [Los Alamos National Laboratory; Winske, Dan [Los Alamos National Laboratory; Wu, Pin [BOSTON UNIV.; Schwadron, N A [BOSTON UNIV.; Lee, M [UNIV OF NEW HAMPSHIRE

    2009-01-01

    The Los Alamos hybrid simulation code is used to examine heating and the partition of dissipation energy at the perpendicular heliospheric termination shock in the presence of pickup ions. The simulations are one-dimensional in space but three-dimensional in field and velocity components, and are carried out for a range of values of pickup ion relative density. Results from the simulations show that because the solar wind ions are relatively cold upstream, the temperature of these ions is raised by a relatively larger factor than the temperature of the pickup ions. An analytic model for energy partition is developed on the basis of the Rankine-Hugoniot relations and a polytropic energy equation. The polytropic index {gamma} used in the Rankine-Hugoniot relations is varied to improve agreement between the model and the simulations concerning the fraction of downstream heating in the pickup ions as well as the compression ratio at the shock. When the pickup ion density is less than 20%, the polytropic index is about 5/3, whereas for pickup ion densities greater than 20%, the polytropic index tends toward 2.2, suggesting a fundamental change in the character of the shock, as seen in the simulations, when the pickup ion density is large. The model and the simulations both indicate for the upstream parameters chosen for Voyager 2 conditions that the pickup ion density is about 25% and the pickup ions gain the larger share (approximately 90%) of the downstream thermal pressure, consistent with Voyager 2 observations near the shock.

  1. THE ROLE OF PICKUP IONS ON THE STRUCTURE OF THE VENUSIAN BOW SHOCK AND ITS IMPLICATIONS FOR THE TERMINATION SHOCK

    International Nuclear Information System (INIS)

    Lu Quanming; Shan Lican; Zhang Tielong; Wu Mingyu; Wang Shui; Zank, Gary P.; Yang Zhongwei; Du Aimin

    2013-01-01

    The recent crossing of the termination shock by Voyager 2 has demonstrated the important role of pickup ions (PUIs) in the physics of collisionless shocks. The Venus Express (VEX) spacecraft orbits Venus in a 24 hr elliptical orbit that crosses the bow shock twice a day. VEX provides a unique opportunity to investigate the role of PUIs on the structure of collisionless shocks more generally. Using VEX observations, we find that the strength of the Venusian bow shock is weaker when solar activity is strong. We demonstrate that this surprising anti-correlation is due to PUIs mediating the Venusian bow shock

  2. Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode

    Energy Technology Data Exchange (ETDEWEB)

    Angelico, E.; Seiss, T. [Enrico Fermi Institute, University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637 (United States); Adams, B. [Incom, Inc., 294 SouthBridge Rd, Charlton, Massachusetts 01507 (United States); Elagin, A.; Frisch, H.; Spieglan, E. [Enrico Fermi Institute, University of Chicago, 5640 S Ellis Ave, Chicago, IL 60637 (United States)

    2017-02-21

    We have designed and tested a robust 20×20 cm{sup 2} thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10 nm-thick NiCr film deposited on a 96% pure Al{sub 2}O{sub 3} 3 mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50 Ω 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20×20 cm{sup 2} array of 2-dimensional square ‘pads’ with sides of 1.27 cm or 2.54 cm. The rise-time of the fast input pulse is maintained for both pickup patterns. For the pad pattern, we observe 80% of the directly coupled amplitude. For the strip pattern we measure 34% of the directly coupled amplitude on the central strip of a broadened signal. The physical decoupling of the photodetector from the pickup pattern allows easy customization for different applications while maintaining high analog bandwidth.

  3. THE IBEX RIBBON AND THE PICKUP ION RING STABILITY IN THE OUTER HELIOSHEATH. II. MONTE-CARLO AND PARTICLE-IN-CELL MODEL RESULTS

    Energy Technology Data Exchange (ETDEWEB)

    Niemiec, J. [Institute of Nuclear Physics PAN, Radzikowskiego 152 31-342 Krakow (Poland); Florinski, V.; Heerikhuisen, J. [Department of Space Science and Center for Space Plasma and Aeronomic Research, University of Alabama in Huntsville, Huntsville, AL 35899 (United States); Nishikawa, K.-I., E-mail: jacek.niemiec@ifj.edu.pl, E-mail: vaf0001@uah.edu, E-mail: jh0004@uah.edu, E-mail: ken-ichi.nishikawa-1@nasa.gov [Department of Physics, University of Alabama in Huntsville, Huntsville, AL 35899 (United States)

    2016-08-01

    The nearly circular ribbon of energetic neutral atom (ENA) emission discovered by NASA’s Interplanetary Boundary EXplorer satellite ( IBEX ), is most commonly attributed to the effect of charge exchange of secondary pickup ions (PUIs) gyrating about the magnetic field in the outer heliosheath (OHS) and the interstellar space beyond. The first paper in the series (Paper I) presented a theoretical analysis of the pickup process in the OHS and hybrid-kinetic simulations, revealing that the kinetic properties of freshly injected proton rings depend sensitively on the details of their velocity distribution. It was demonstrated that only rings that are not too narrow (parallel thermal spread above a few km s{sup −1}) and not too wide (parallel temperature smaller than the core plasma temperature) could remain stable for a period of time long enough to generate ribbon ENAs. This paper investigates the role of electron dynamics and the extra spatial degree of freedom in the ring ion scattering process with the help of two-dimensional full particle-in-cell (PIC) kinetic simulations. A good agreement is observed between ring evolution under unstable conditions in hybrid and PIC models, and the dominant modes are found to propagate parallel to the magnetic field. We also present more realistic ribbon PUI distributions generated using Monte Carlo simulations of atomic hydrogen in the global heliosphere and examine the effect of both the cold ring-like and the hot “halo” PUIs produced from heliosheath ENAs on the ring stability. It is shown that the second PUI population enhances the fluctuation growth rate, leading to faster isotropization of the solar-wind-derived ring ions.

  4. Solar wind heating by an embedded quasi-isothermal pick-up ion fluid

    Directory of Open Access Journals (Sweden)

    H. J. Fahr

    Full Text Available It is well known that the solar wind plasma consists of primary ions of solar coronal origin and secondary ions of interstellar origin. Interstellar H-atoms penetrate into the inner heliosphere and when ionized there are converted into secondary ions. These are implanted into the magnetized solar wind flow and are essentially enforced to co-move with this flow. By nonlinear interactions with wind-entrained Alfvén waves the latter are processed in the co-moving velocity space. This pick-up process, however, also causes actions back upon the original solar wind flow, leading to a deceleration, as well as a heating of the solar wind plasma. The resulting deceleration is not only due to the loading effect, but also due to the action of the pressure gradient. To calculate the latter, it is important to take into account the stochastic acceleration that suffers at their convection out of the inner heliosphere by the quasi-linear interactions with MHD turbulences. Only then can the presently reported VOYAGER observations of solar wind decelerations and heatings in the outer heliosphere be understood in terms of the current, most likely values of interstellar gas parameters. In a consistent view of the thermodynamics of the solar wind plasma, which is composed of secondary ions and solar wind protons, we also derive that the latter are globally heated at their motion to larger solar distances. The arising heat transfer is due to the action of suprathermal ions which drive MHD waves that are partially absorbed by solar wind protons and thereby establish their observed quasi-polytropy. We obtain a quantitative expression for the solar wind proton pressure as a function of solar distance. This expression clearly shows the change from an adiabatic to a quasi-polytropic behaviour with a decreasing polytropic index at increasing distances, as has been observed by the VOYAGERS. This also allows one to calculate the average percentage of the intitial energy

  5. Solar wind heating by an embedded quasi-isothermal pick-up ion fluid

    Directory of Open Access Journals (Sweden)

    H. J. Fahr

    2002-10-01

    Full Text Available It is well known that the solar wind plasma consists of primary ions of solar coronal origin and secondary ions of interstellar origin. Interstellar H-atoms penetrate into the inner heliosphere and when ionized there are converted into secondary ions. These are implanted into the magnetized solar wind flow and are essentially enforced to co-move with this flow. By nonlinear interactions with wind-entrained Alfvén waves the latter are processed in the co-moving velocity space. This pick-up process, however, also causes actions back upon the original solar wind flow, leading to a deceleration, as well as a heating of the solar wind plasma. The resulting deceleration is not only due to the loading effect, but also due to the action of the pressure gradient. To calculate the latter, it is important to take into account the stochastic acceleration that suffers at their convection out of the inner heliosphere by the quasi-linear interactions with MHD turbulences. Only then can the presently reported VOYAGER observations of solar wind decelerations and heatings in the outer heliosphere be understood in terms of the current, most likely values of interstellar gas parameters. In a consistent view of the thermodynamics of the solar wind plasma, which is composed of secondary ions and solar wind protons, we also derive that the latter are globally heated at their motion to larger solar distances. The arising heat transfer is due to the action of suprathermal ions which drive MHD waves that are partially absorbed by solar wind protons and thereby establish their observed quasi-polytropy. We obtain a quantitative expression for the solar wind proton pressure as a function of solar distance. This expression clearly shows the change from an adiabatic to a quasi-polytropic behaviour with a decreasing polytropic index at increasing distances, as has been observed by the VOYAGERS. This also allows one to calculate the average percentage of the intitial energy

  6. Comparative study of ion cyclotron waves at Mars, Venus and Earth

    Science.gov (United States)

    Wei, H. Y.; Russell, C. T.; Zhang, T. L.; Blanco-Cano, X.

    2011-08-01

    Ion cyclotron waves are generated in the solar wind when it picks up freshly ionized planetary exospheric ions. These waves grow from the free energy of the highly anisotropic distribution of fresh pickup ions, and are observed in the spacecraft frame with left-handed polarization and a wave frequency near the ion's gyrofrequency. At Mars and Venus and in the Earth's polar cusp, the solar wind directly interacts with the planetary exospheres. Ion cyclotron waves with many similar properties are observed in these diverse plasma environments. The ion cyclotron waves at Mars indicate its hydrogen exosphere to be extensive and asymmetric in the direction of the interplanetary electric field. The production of fast neutrals plays an important role in forming an extended exosphere in the shape and size observed. At Venus, the region of exospheric proton cyclotron wave production may be restricted to the magnetosheath. The waves observed in the solar wind at Venus appear to be largely produced by the solar-wind-Venus interaction, with some waves at higher frequencies formed near the Sun and carried outward by the solar wind to Venus. These waves have some similarity to the expected properties of exospherically produced proton pickup waves but are characterized by magnetic connection to the bow shock or by a lack of correlation with local solar wind properties respectively. Any confusion of solar derived waves with exospherically derived ion pickup waves is not an issue at Mars because the solar-produced waves are generally at much higher frequencies than the local pickup waves and the solar waves should be mostly absorbed when convected to Mars distance as the proton cyclotron frequency in the plasma frame approaches the frequency of the solar-produced waves. In the Earth's polar cusp, the wave properties of ion cyclotron waves are quite variable. Spatial gradients in the magnetic field may cause this variation as the background field changes between the regions in which

  7. INTERSTELLAR PICK-UP IONS OBSERVED BETWEEN 11 AND 22 AU BY NEW HORIZONS

    International Nuclear Information System (INIS)

    Randol, B. M.; McComas, D. J.; Schwadron, N. A.

    2013-01-01

    We report new observations by the Solar Wind Around Pluto instrument on the New Horizons spacecraft, which measures energy per charge (E/q) spectra of solar wind and interstellar pick-up ions (PUIs) between 11 AU and 22 AU from the Sun. The data provide an unprecedented look at PUIs as there have been very few measurements of PUIs beyond 10 AU. We analyzed the PUI part of the spectra by comparing them to the classic Vasyliunas and Siscoe PUI model. Our analysis indicates that PUIs are usually well-described by this distribution. We derive parameters relevant to PUI studies, such as the ionization rate normalized to 1 AU. Our result for the average ionization rate between 11 and 12 AU agrees with an independently derived average value found during the same time. Later, we find a general increase in the ionization rate, which is consistent with the increase in solar activity. We also calculate the PUI thermal pressure, which appears to be roughly consistent with previous results. Through fitting of the solar wind proton peaks in our spectra, we derive solar wind thermal pressures. Based on our analysis, we predict a ratio of PUI thermal pressure to solar wind thermal pressure just inside the termination shock to be between 100 and >1000.

  8. Investigating Systematic Errors of the Interstellar Flow Longitude Derived from the Pickup Ion Cutoff

    Science.gov (United States)

    Taut, A.; Berger, L.; Drews, C.; Bower, J.; Keilbach, D.; Lee, M. A.; Moebius, E.; Wimmer-Schweingruber, R. F.

    2017-12-01

    Complementary to the direct neutral particle measurements performed by e.g. IBEX, the measurement of PickUp Ions (PUIs) constitutes a diagnostic tool to investigate the local interstellar medium. PUIs are former neutral particles that have been ionized in the inner heliosphere. Subsequently, they are picked up by the solar wind and its frozen-in magnetic field. Due to this process, a characteristic Velocity Distribution Function (VDF) with a sharp cutoff evolves, which carries information about the PUI's injection speed and thus the former neutral particle velocity. The symmetry of the injection speed about the interstellar flow vector is used to derive the interstellar flow longitude from PUI measurements. Using He PUI data obtained by the PLASTIC sensor on STEREO A, we investigate how this concept may be affected by systematic errors. The PUI VDF strongly depends on the orientation of the local interplanetary magnetic field. Recently injected PUIs with speeds just below the cutoff speed typically form a highly anisotropic torus distribution in velocity space, which leads to a longitudinal transport for certain magnetic field orientation. Therefore, we investigate how the selection of magnetic field configurations in the data affects the result for the interstellar flow longitude that we derive from the PUI cutoff. Indeed, we find that the results follow a systematic trend with the filtered magnetic field angles that can lead to a shift of the result up to 5°. In turn, this means that every value for the interstellar flow longitude derived from the PUI cutoff is affected by a systematic error depending on the utilized magnetic field orientations. Here, we present our observations, discuss possible reasons for the systematic trend we discovered, and indicate selections that may minimize the systematic errors.

  9. Five Characteristics of China Made Pickup

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    <正> Compared with imported ones, the domestic-made pick-ups have the characteristics as follows: Technology: over the past several years, along with the fierce market competition, the technologies of over 30 pick-up makers in China seem to be mature. Some makers have possessed a production capacity of 30,000 units every

  10. Assessing tether anchor labeling and usability in pickup trucks.

    Science.gov (United States)

    Klinich, Kathleen D; Manary, Miriam A; Malik, Laura A; Flannagan, Carol A; Jermakian, Jessica S

    2018-04-03

    The objective of this study was to investigate vehicle factors associated with child restraint tether use and misuse in pickup trucks and evaluate 4 labeling interventions designed to educate consumers on proper tether use. Volunteer testing was performed with 24 subjects and 4 different pickup trucks. Each subject performed 8 child restraint installations among the 4 pickups using 2 forward-facing restraints: a Britax Marathon G4.1 and an Evenflo Triumph. Vehicles were selected to represent 4 different implementations of tether anchors among pickups: plastic loop routers (Chevrolet Silverado), webbing routers (Ram), back wall anchors (Nissan Frontier), and webbing routers plus metal anchors (Toyota Tundra). Interventions included a diagram label, Quick Response (QR) Code linked to video instruction, coordinating text label, and contrasting text tag. Subjects used the child restraint tether in 93% of trials. However, tether use was completely correct in only 9% of trials. An installation was considered functional if the subject attached the tether to a tether anchor and had a tight installation (ignoring routing and head restraint position); 28% of subjects achieved a functional installation. The most common installation error was attaching the tether hook to the anchor/router directly behind the child restraint (near the top of the seatback) rather than placing the tether through the router and attaching it to the anchor in the adjacent seating position. The Nissan Frontier, with the anchor located on the back wall of the cab, had the highest rate of correct installations but also had the highest rate of attaching the tether to components other than the tether anchor (seat adjustor, child restraint storage hook, around head restraint). None of the labeling interventions had a significant effect on correct installation; not a single subject scanned the QR Code to access the video instruction. Subjects with the most successful installations spent extensive time

  11. Electromagnetically-induced nuclear-charge pickup observed in ultra-relativistic Pb collisions

    International Nuclear Information System (INIS)

    Scheidenberger, C.; Aumann, T.; Pshenichnov, I.A.; Russian Academy of Sciences, Moscow

    2002-01-01

    A strong increase of inclusive nuclear-charge pickup cross sections, forming 83 Bi from 158 A GeV 82 Pb ions, is observed in comparison to similar measurements at 10.6 A GeV. From the dependence of these cross sections on target atomic number, this increase is attributed to the electromagnetic process of pion production by equivalent photons. The observed cross sections can be reproduced quantitatively using the recently developed RELDIS code. (orig.)

  12. A study of charge-pickup interactions by (158A GeV) Pb nuclei

    International Nuclear Information System (INIS)

    Sher, G.; Shahzad, M.I.

    2012-01-01

    Study of the relativistic heavy-ion collision is important to focus on probing phase transitions between hadrons and quark-gluon phases in the extreme conditions of temperature and density of nuclear matter formed in the collisions. These states of nuclear matter are expected to be created in relativistic nuclear collisions with large overlap of interacting nuclei, the Lorentz-boosted Coulomb potential Vc proportional to alpha gamma Z/b of a partner with charge Z is very strong, where b is impact parameter and is the fine structure constant. Either one or both nuclei may be disintegrated by the electromagnetic forces in ultra-peripheral collisions at b = R1 + R2, where R1 and R2 are the nuclear radii. This distinct feature of electromagnetic dissociation makes it possible to study the behavior of nuclear matter under electromagnetic fields. The nuclear charge-pickup ( delta Z = +1) by Pb projectiles at energy 158A GeV interacting with targets Bi, Pb, Cu and Al was investigated using CR39 nuclear track detectors. The target-detector stacks were exposed at CERN SPS beam facility. The projectile and fragments charge states have been identified using the etch-cone lengths for charge-pickup at Z = 83 of residual nuclei. Our measured charge-pickup cross sections (delta Z = +1) are shown. It was observed that for the heavy targets the increase in the cross section is anticipated by substantial contribution of electromagnetic dissociation process of production by virtual photons which is almost negligible at 10.6A GeV. In the light target region, our measured cross sections and charge-pickup cross sections reported at energy 10.6A GeV show dominant nuclear contribution and very small contribution of electromagnetic dissociation term. A strong dependence of charge-pickup cross sections on the target mass number was observed particularly in the heavy targets. (orig./A.B.)

  13. High frequency permeameter with semi-rigid pick-up coil

    International Nuclear Information System (INIS)

    Shin, Sung-Yong; Shin, Kwang-Ho . E-mail : khshin@star.ks.ac.kr; Kim, Jong-sung; Kim, Young-Hak; Lim, Sang-Ho; Sa-gong, Geon

    2006-01-01

    In this study, we propose the application of semi-rigid cable loop as a single turn shielded loop pick-up coil for the high frequency permeameter. Since the semi-rigid cable pick-up coil has simple structure, it is very easy to make the pick-up coil with bending and conventional soldering. The permeability of cobalt base amorphous ribbon was investigated using the developed permeameter for demonstrating its performance. The permeability of the amorphous ribbon was driven from the S-parameters measured using a network analyzer and permameter having the semi-rigid pick-up coil

  14. Electrostatic pickup station

    CERN Multimedia

    CERN PhotoLab

    1982-01-01

    Electrostatic pickup station, with 4 interleaved electrodes, to measure beam position in the horizontal and vertical plane. This type is used in the transfer lines leaving the PS (TT2, TT70, TTL2). See also 7904075.

  15. Resonant interactions between cometary ions and low frequency electromagnetic waves

    Science.gov (United States)

    Thorne, Richard M.; Tsurutani, Bruce T.

    1987-01-01

    The conditions for resonant wave amplification in a plasma with a ring-beam distribution which is intended to model pick-up ions in a cometary environment are investigated. The inclination between the interplanetary field and the solar wind is found to play a crucial role in governing both the resonant frequency and the growth rate of any unstable mode. It is suggested that the low-frequency MHD mode should experience the most rapid amplification for intermediate inclination. In the frame of the solar wind, such waves should propagate along the field in the direction upstream toward the sun with a phase speed lower than the beaming velocity of the pick-up ions. This mechanism may account for the presence of the interior MHD waves noted by satellites over a region surrounding comets Giacobini-Zinner and Halley.

  16. AA, closed orbit observation pickup

    CERN Multimedia

    1980-01-01

    Electrostatic pickups around the circumference of the AA served for the measurement of the closed orbits across the wide momentum range of +- 3% to either side of central orbit. The pickups were of the "shoebox" type, with diagonal cuts, a horizontal and a vertical one mechanically coupled together. They were located where they would not require extra space. The small ones, like the one we see here, were inserted into the vacuum chamber of the BLG (long and narrow) bending magnets. See also 8001372, 8010042, 8010045

  17. Comparison of magnetosonic wave and water group ion energy densities at Comet Giacobini-Zinner

    Science.gov (United States)

    Staines, K.; Balogh, A.; Cowley, S. W. H.; Forster, P. M. De F.; Hynds, R. J.; Yates, T. S.; Sanderson, T. R.; Wenzel, K.-P.; Tsurutani, B. T.

    1991-01-01

    Measurements of the Comet Giacobini-Zinner (GZ) are presented to determine to what extent wave-particle scattering redistributed the initial pick-up energy of the ion population. Also examined is the difference between the ion thermal energy and the energy in the magnetic fields of the waves. In spite of uncertainty of about a factor of 2 noted in the pick-up and mass-loaded regions, it is shown that less than approximately 50 percent of the pick-up energy is converted into wave magnetic energy in the inbound pick-up region.

  18. High-performance pickups for beam diagnostics. Design, analysis, characterization and implementation

    International Nuclear Information System (INIS)

    Angelovski, Aleksandar

    2015-01-01

    This work introduces the design, analysis, characterization and implementation of high-performance pickups for two beam diagnostic instruments, a Bunch Arrival-time Monitor (BAM) and an Energy Beam Position Monitor (EBPM) at the European XFEL. As a part of the BAM the cone-shaped pickups are proposed along with the corresponding RF-frontend. The designed pickups deliver a beam induced signal with a slope steepness of around 400 mV/ps and a bandwidth of 40 GHz. These signal characteristics are well inside the design requirements, i.e., a slope steepness of 300 mV/ps and more than ten times better compared to the signal from the state-of-the-art pickups. The pickups are installed and commissioned at three accelerator facilities, FLASH at DESY, the quasi-CW SRF accelerator ELBE at the Helmholtz-Zentrum Dresden-Rossendorf and the SwissFEL injector test facility at Paul Scherrer Institute. The obtained measurement results from the installed pickups are in good agreement with the simulations. A comparison between the signal measurements with the cone-shaped pickup and the state-of-the-art is performed at ELBE showing an improvement by a factor of ten. The potential of the pickups for sub-10 fs arrival-time measurements for bunch charges of 20 pC is demonstrated at ELBE and at SwissFEL injector test facility. The introduced coneshaped pickups are the first commercially available pickups with a bandwidth of up to 40 GHz. For the EBPM, a modular pickup structure with two types of planar pickups, microstrip transmission line and grounded coplanar waveguide with perpendicular connectors is investigated. The transition region between the connector and the line is optimized for two substrate materials, alumina and glass with a reflection coefficient better than -20 dB up to 6 GHz.

  19. AA, closed orbit observation pickup

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    Electrostatic pickups around the circumference of the AA served for the measurement of the closed orbits across the wide momentum range of +- 3% to either side of central orbit. The pickups were of the "shoebox" type, with diagonal cuts, a horizontal and a vertical one mechanically coupled together. They were located where they would not require extra space. The wide ones (very wide indeed: 70 cm), like the one we see here, were placed inside the vacuum chamber of the wide quadrupoles QFW, at maximum dispersion. See also 8001372, 8001383, 8010045

  20. AA, closed orbit observation pickup

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    Electrostatic pickups around the circumference of the AA served for the measurement of the closed orbits across the wide momentum range of +- 3% to either side of central orbit. The pickups were of the "shoebox" type, with diagonal cuts, a horizontal and a vertical one mechanically coupled together. They were located where they would not require extra space. The wide ones (very wide indeed: 70 cm), like the one we see here, were placed inside the vacuum chamber of the wide quadrupoles, QFW, at maximum dispersion. See also 8001372,8001383, 8010042

  1. AA, closed orbit observation pickup

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    Electrostatic pickups around the circumference of the AA served for the measurement of the closed orbits across the wide momentum range of +- 3% to either side of central orbit. The pickups were of the "shoebox" type, with diagonal cuts, a horizontal and a vertical one mechanically coupled together. They were located where they would not require extra space. The small ones, like the one we see here, were inserted into the vacuum chamber of the BLG (long and narrow) bending magnets. Werner Sax contemplates his achievement. See also 8001383, 8010042, 8010045.

  2. Electrostatic pickup station

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    Electrostatic pickup station, with 4 electrodes, to measure beam position in the horizontal and vertical plane. This type is used in the transfer lines leaving the PS (TT2, TTL2, TT70). See also 8206063, where the electrode shapes are clearly visible.

  3. Observations from 1 to 6 AU of Low-Frequency Magnetic Waves due to Newborn Interstellar Pickup Ions Using Ulysses, Voyager and ACE Data

    Science.gov (United States)

    Smith, C. W.; Aggarwal, P.; Argall, M. R.; Burlaga, L. F.; Bzowski, M.; Cannon, B. E.; Gary, S. P.; Fisher, M. K.; Gilbert, J. A.; Hollick, S. J.; Isenberg, P. A.; Joyce, C. J.; Murphy, N.; Nuno, R. G.; Pine, Z. B.; Richardson, J. D.; Schwadron, N.; Skoug, R. M.; Sokol, J. M.; Taylor, D. K.; Vasquez, B. J.; Zurbuchen, T.

    2016-12-01

    Wave excitation by newborn interstellar pickup ions (PUIs) play a significant role in theories that attempt to describe IBEX and Voyager observations in the heliosheath as well as solar wind heating. The same dynamic processes can be far-reaching and extend into the inner heliosphere to at least 1AU and likely to smaller heliocentric distances. While the high-resolution magnetic field measurements required to study these waves are not yet available in the heliosheath, we have studied a range of available observations and found evidence of waves due to interstellar PUIs using ACE (1998-2015 at 1 AU), Ulysses (1996-2006 at 2 to 5 AU, high and low latitudes) and Voyager (1978-1979 and 2 to 6 AU) observations. Efforts to extend the Voyager observations to 35 AU are ongoing. We have examined these data sets and report on observations of low-frequency waves that result from newborn interstellar pickup H+ and He+ ions. Although not as common as theory once predicted, we presently have identified 524 independent occurrences. Our conclusion from studying these waves is that they are seen only when the ambient turbulence is sufficiently weak. The instability that leads to the generation of these waves requires a slow accumulation of wave energy over several to tens of hours to achieve the observed wave amplitudes. In regions where the turbulence is moderate to strong, the turbulence consumes the wave energy before it can reach observable levels and transports the energy to the dissipation scales where it heats the background thermal particles. Only intervals with the weakest turbulence will permit energy accumulation over this time scale. These conditions are most often, but not exclusively, achieved in solar wind rarefaction regions.

  4. INTERSTELLAR PICKUP ION ACCELERATION IN THE TURBULENT MAGNETIC FIELD AT THE SOLAR WIND TERMINATION SHOCK USING A FOCUSED TRANSPORT APPROACH

    Energy Technology Data Exchange (ETDEWEB)

    Ye, Junye; Roux, Jakobus A. le; Arthur, Aaron D. [Department of Space Science, University of Alabama in Huntsville, Huntsville, AL 35899 (United States)

    2016-08-01

    We study the physics of locally born interstellar pickup proton acceleration at the nearly perpendicular solar wind termination shock (SWTS) in the presence of a random magnetic field spiral angle using a focused transport model. Guided by Voyager 2 observations, the spiral angle is modeled with a q -Gaussian distribution. The spiral angle fluctuations, which are used to generate the perpendicular diffusion of pickup protons across the SWTS, play a key role in enabling efficient injection and rapid diffusive shock acceleration (DSA) when these particles follow field lines. Our simulations suggest that variation of both the shape ( q -value) and the standard deviation ( σ -value) of the q -Gaussian distribution significantly affect the injection speed, pitch-angle anisotropy, radial distribution, and the efficiency of the DSA of pickup protons at the SWTS. For example, increasing q and especially reducing σ enhances the DSA rate.

  5. Characterization of BPM pickup designs for the HESR rate at FAIR using simulations and numerical calculations

    Energy Technology Data Exchange (ETDEWEB)

    Halama, Arthur; Kamerdzhiev, Vsevolod; Boehme, Christian; Srinivasan, Sudharsan [Forschungszentrum Juelich, IKP-4 (Germany)

    2016-07-01

    The institute of Nuclear Physics 4(IKP-4) of the Research Center Juelich (FZJ) is in charge of building and commissioning the High Energy Storage Ring (HESR) within the international Facility for Antiproton and Ion Research (FAIR) at Darmstadt. Simulations and numerical calculations were performed to characterize the initial beam position pickup design. Capacitive couplings of the electrodes and the behavior of the electrical equivalent circuit were investigated. This made room for changes to the design and performance increase. A prototype of the BPM pickup was constructed and tested on a dedicated test bench. Preliminary results will be presented. In order to gain higher signal levels and higher sensitivity, another suggested design was characterized as well and put into comparison.

  6. Naturalistic drive cycle synthesis for pickup trucks.

    Science.gov (United States)

    Liu, Zifan; Ivanco, Andrej; Filipi, Zoran

    2015-09-01

    Future pick-up trucks are meeting much stricter fuel economy and exhaust emission standards. Design tradeoffs will have to be carefully evaluated to satisfy consumer expectations within the regulatory and cost constraints. Boundary conditions will obviously be critical for decision making: thus, the understanding of how customers are driving in naturalistic settings is indispensable. Federal driving schedules, while critical for certification, do not capture the richness of naturalistic cycles, particularly the aggressive maneuvers that often shape consumer perception of performance. While there are databases with large number of drive cycles, applying all of them directly in the design process is impractical. Therefore, representative drive cycles that capture the essence of the naturalistic driving should be synthesized from naturalistic driving data. Naturalistic drive cycles are firstly categorized by investigating their micro-trip components, defined as driving activities between successive stops. Micro-trips are expected to characterize underlying local traffic conditions, and separate different driving patterns. Next, the transitions from one vehicle state to another vehicle state in each cycle category are captured with Transition Probability Matrix (TPM). Candidate drive cycles can subsequently be synthesized using Markov Chain based on TPMs for each category. Finally, representative synthetic drive cycles are selected through assessment of significant cycle metrics to identify the ones with smallest errors. This paper provides a framework for synthesis of representative drive cycles from naturalistic driving data, which can subsequently be used for efficient optimization of design or control of pick-up truck powertrains. Manufacturers will benefit from representative drive cycles in several aspects, including quick assessments of vehicle performance and energy consumption in simulations, component sizing and design, optimization of control strategies, and

  7. Ford F250 Dedicated CNG Pickup

    International Nuclear Information System (INIS)

    Eudy, Leslie

    1999-01-01

    The U.S. Department of Energy (DOE) is encouraging the use of alternative fuels and alternative fuel vehicles (AFVs). To support this activity, DOE has directed the National Renewable Energy Laboratory (NREL) to conduct projects to evaluate the performance and acceptability of light-duty AFVs. In this study, we tested a pair of 1998 Ford F-250 pickups: one dedicated compressed natural gas (CNG) model and a gasoline model as closely matched as possible. Each vehicle was run through a series of tests to evaluate acceleration, fuel economy, braking, and cold-start capabilities, as well as more subjective performance indicators such as handling, climate control, and noise

  8. Simulated orbits of heavy planetary ions at Mars for different IMF configurations

    Science.gov (United States)

    Curry, Shannon; Luhmann, Janet; Livi, Roberto; Hara, Takuya; Dong, Chuanfei; Ma, Yingjuan; McFadden, James; Bougher, Stephen

    2014-11-01

    We present simulated detections of O+, O2+ and CO2+ ions at Mars along a virtual orbit in the Mars space environment. Planetary pick-up ions are formed through the direct interaction of the solar wind with the neutral upper atmosphere, causing the newly created ions to be picked up and accelerated by the background convective electric field. Because previous missions such as Mars Global Surveyor (MGS) and Mars Express (MEX) have not been able to measure the interplanetary magnetic field (IMF) components simultaneously with plasma measurements, the response of heavy planetary pick-up ions to changes in the IMF has not been well characterized. Using a steady-state multi-species MHD model to provide the background electric and magnetic fields, the Mars Test Particle (MTP) simulation can trace each of these particles along field lines in near-Mars space and construct virtual ion detections from a spacecraft orbit. Specifically, we will present energy-time spectrograms and velocity space distributions (VSDs) for a selection of orbits during different IMF configurations and solar cycle conditions. These simulated orbits have broader implications for how to measure ion escape. Using individual particle traces, the origin and trajectories of different ion populations can be analyzed in order to assess how and where they contribute to the total atmospheric escape rate, which is a major objective of the upcoming MAVEN mission.

  9. Ulysses observations of magnetic waves due to newborn interstellar pickup ions. II. Application of turbulence concepts to limiting wave energy and observability

    Energy Technology Data Exchange (ETDEWEB)

    Cannon, Bradford E. [Physics Department, Florida State University, Tallahassee, FL 32306 (United States); Smith, Charles W.; Isenberg, Philip A.; Vasquez, Bernard J.; Joyce, Colin J. [Physics Department and Space Science Center, Institute for the Study of Earth, Oceans, and Space, University of New Hampshire, Durham, NH 03824 (United States); Murphy, Neil [Jet Propulsion Laboratory, Mail Stop 180-600, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States); Nuno, Raquel G., E-mail: bc13h@my.fsu.edu, E-mail: Charles.Smith@unh.edu, E-mail: Phil.Isenberg@unh.edu, E-mail: Bernie.Vasquez@unh.edu, E-mail: cjl46@wildcats.unh.edu, E-mail: Neil.Murphy@jpl.nasa.gov, E-mail: raquel.nuno@asu.edu [School of Earth and Space Exploration, Arizona State University, Tempe, AZ 85287 (United States)

    2014-06-01

    The low-frequency magnetic waves that arise from the isotropization of newborn interstellar pickup ions (PUIs) are reasonably well described by linear and quasi-linear kinetic theory in so far as those theories predict the wave frequency and polarization in the spacecraft frame. Those theories fail to describe the scarce observability of the waves. Quasilinear theory predicts that the wave power should accumulate over long periods of time as the relatively weak kinetic instability slowly adds power to the observed spectrum. At the same time it has been argued that the same wave energy must serve as a secondary source of thermal ion heating in the outer heliosphere once the initial turbulence is depleted. To the extent that turbulent transport of the wave energy acts against the spectrally confined accumulation of wave energy, turbulence should be a limiting factor in observability. We argue that turbulence does limit the observability of the waves and we use turbulence theory to predict the observed wave energy. We compare this prediction against a database of 502 wave observations attributed to newborn interstellar PUIs observed by the Ulysses spacecraft.

  10. Ulysses observations of magnetic waves due to newborn interstellar pickup ions. II. Application of turbulence concepts to limiting wave energy and observability

    International Nuclear Information System (INIS)

    Cannon, Bradford E.; Smith, Charles W.; Isenberg, Philip A.; Vasquez, Bernard J.; Joyce, Colin J.; Murphy, Neil; Nuno, Raquel G.

    2014-01-01

    The low-frequency magnetic waves that arise from the isotropization of newborn interstellar pickup ions (PUIs) are reasonably well described by linear and quasi-linear kinetic theory in so far as those theories predict the wave frequency and polarization in the spacecraft frame. Those theories fail to describe the scarce observability of the waves. Quasilinear theory predicts that the wave power should accumulate over long periods of time as the relatively weak kinetic instability slowly adds power to the observed spectrum. At the same time it has been argued that the same wave energy must serve as a secondary source of thermal ion heating in the outer heliosphere once the initial turbulence is depleted. To the extent that turbulent transport of the wave energy acts against the spectrally confined accumulation of wave energy, turbulence should be a limiting factor in observability. We argue that turbulence does limit the observability of the waves and we use turbulence theory to predict the observed wave energy. We compare this prediction against a database of 502 wave observations attributed to newborn interstellar PUIs observed by the Ulysses spacecraft.

  11. Interference between direct and indirect modes in two-nucleon transfer reactions with heavy ions

    International Nuclear Information System (INIS)

    Scott, D.K.; Harvey, B.G.; Hendrie, D.L.; Jahnke, U.; Kraus, L.; Maguire, C.F.; Mahoney, J.; Terrien, Y.; Yagi, K.; Glendenning, N.K.

    1975-01-01

    Direct and indirect transitions to the lowest 2 + collective states are shown to interfere constructively in the pickup reaction 122 Sn( 16 O, 18 O) 120 Sn at 104 MeV, and destructively in the inverse stripping reaction 120 Sn( 18 O, 16 O) 122 Sn at 99 MeV

  12. Slot-type pickup/kicker for AA stochastic cooling

    CERN Multimedia

    1979-01-01

    A "slotted transmission line" was used for both pickups and kickers of the stochastic cooling systems of the AA. They served for the cooling of the high-density antiproton stack, in momentum and both transverse planes. In the beginning, in a single band, 1-2 GHz, later in 2 bands, 2-4 and 4-8 GHz. View down the centre of a pickup or kicker. See also 7906189, 7906190, 7906583.

  13. The pick-up mechanism in composite particle emission processes

    International Nuclear Information System (INIS)

    Zhang Jingshang; Yan Shiwei; Wang Cuilan

    1992-01-01

    The pick-up mechanism has been included in the exciton model for the light composite particle emissions. Based on the cluster phase space integration method the formation probabilities of α,d,t, 3 He are obtained. The calculation results of (n,t) cross sections indicate that this theoretical method can reproduce the experimental data nicely. For triton emissions in pre-equilibrium reaction processes, the semi-direct reactions are the dominant terms which are just omitted in the previous model calculation

  14. Dynamic devices: A primer on pickups and kickers

    International Nuclear Information System (INIS)

    Goldberg, D.A.; Lambertson, G.R.

    1991-11-01

    A charged-particle beam generates electromagnetic fields which in turn interact with the beam's surroundings. These interactions can produce fields which act back on the beam itself, or, if the ''surroundings'' are of suitably designed form (e.g., sensing electrodes with electrical connection to the ''outside world''), can provide information on various properties of the beam; such electrodes are generally known as pickups. Similarly, charged- particle beams respond to the presence of externally imposed electromagnetic fields; devices used to generate such fields are generally known as kickers. As we shall show, the behavior of an electrode system when it functions as a pickup is intimately related to its behavior as a kicker. A number of papers on pickup behavior have appeared in recent years in most of which the primary emphasis has been on beam instrumentation; there have also been several workshops on the subject. There have been several papers which have treated both pickup and kicker behavior of a particular electrode system, but this has been done in the context of discussing a specialized application, such as a stochastic cooling system. The approach in the present paper is similar to that of earlier works by one of the authors, which is to provide a unified treatment of pickup and kicker behavior, and, it is hoped, to give the reader an understanding which is both general and fundamental enough to make the above references easily accessible to him. As implied by the revised title, we have done the re-writing with the non-expert in mind. We have made the introduction both lengthier and more detailed, and done the same with much of the explanatory material and discussion

  15. Dynamic devices: A primer on pickups and kickers

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, D.A.; Lambertson, G.R.

    1991-11-01

    A charged-particle beam generates electromagnetic fields which in turn interact with the beam`s surroundings. These interactions can produce fields which act back on the beam itself, or, if the ``surroundings`` are of suitably designed form (e.g., sensing electrodes with electrical connection to the ``outside world``), can provide information on various properties of the beam; such electrodes are generally known as pickups. Similarly, charged- particle beams respond to the presence of externally imposed electromagnetic fields; devices used to generate such fields are generally known as kickers. As we shall show, the behavior of an electrode system when it functions as a pickup is intimately related to its behavior as a kicker. A number of papers on pickup behavior have appeared in recent years in most of which the primary emphasis has been on beam instrumentation; there have also been several workshops on the subject. There have been several papers which have treated both pickup and kicker behavior of a particular electrode system, but this has been done in the context of discussing a specialized application, such as a stochastic cooling system. The approach in the present paper is similar to that of earlier works by one of the authors, which is to provide a unified treatment of pickup and kicker behavior, and, it is hoped, to give the reader an understanding which is both general and fundamental enough to make the above references easily accessible to him. As implied by the revised title, we have done the re-writing with the non-expert in mind. We have made the introduction both lengthier and more detailed, and done the same with much of the explanatory material and discussion.

  16. Dynamic devices: A primer on pickups and kickers

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, D.A.; Lambertson, G.R.

    1991-11-01

    A charged-particle beam generates electromagnetic fields which in turn interact with the beam's surroundings. These interactions can produce fields which act back on the beam itself, or, if the surroundings'' are of suitably designed form (e.g., sensing electrodes with electrical connection to the outside world''), can provide information on various properties of the beam; such electrodes are generally known as pickups. Similarly, charged- particle beams respond to the presence of externally imposed electromagnetic fields; devices used to generate such fields are generally known as kickers. As we shall show, the behavior of an electrode system when it functions as a pickup is intimately related to its behavior as a kicker. A number of papers on pickup behavior have appeared in recent years in most of which the primary emphasis has been on beam instrumentation; there have also been several workshops on the subject. There have been several papers which have treated both pickup and kicker behavior of a particular electrode system, but this has been done in the context of discussing a specialized application, such as a stochastic cooling system. The approach in the present paper is similar to that of earlier works by one of the authors, which is to provide a unified treatment of pickup and kicker behavior, and, it is hoped, to give the reader an understanding which is both general and fundamental enough to make the above references easily accessible to him. As implied by the revised title, we have done the re-writing with the non-expert in mind. We have made the introduction both lengthier and more detailed, and done the same with much of the explanatory material and discussion.

  17. PAL-XFEL cavity beam position monitor pick-up design and beam test

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sojeong, E-mail: sojung8681@postech.ac.kr; Park, Young Jung; Kim, Changbum; Kim, Seung Hwan; Shin, Dong Cheol; Han, Jang-Hui; Ko, In Soo

    2016-08-11

    As an X-ray Free Electron Laser, PAL-XFEL is about to start beam commissioning. X-band cavity beam position monitor (BPM) is used in the PAL-XFEL undulator beam line. Prototypes of cavity BPM pick-up were designed and fabricated to test the RF characteristics. Also, the beam test of a cavity BPM pick-up was done in the Injector Test Facility (ITF). In the beam test, the raw signal properties of the cavity BPM pick-up were measured at a 200 pC bunch charge. According to the RF test and beam test results, the prototype cavity BPM pick-up design was confirmed to meet the requirements of the PAL-XFEL cavity BPM system.

  18. Structure of Ion Outflow in the Martian Magnetotail

    Science.gov (United States)

    McFadden, J. P.; Mitchell, D.; Luhmann, J. G.; Connerney, J. E. P.; Jakosky, B. M.

    2017-12-01

    The Suprathermal And Thermal Ion Composition (STATIC) sensor on the MAVEN spacecraft provides a detailed look at the structure of ion outflow in the Martian magnetotail including ion composition, energization, and flow. Mars' magnetotail contains a mixture of cold (multi-species ions, tailward-moving cold multi-species ions, suprathermal ions of a few tens of eV, warm (about 100 eV) proton populations, and heavy (primarily O+) pickup ions at energies from 1 to 10 keV which may display several simultaneous peaks in energy flux. The cold tailward-moving ions represent a significant fraction of the Martian ion loss, perhaps comparable to loses from molecular oxygen dissociation. The suprathermal tail that accompanies the cold ions varies greatly and provides clues to ion escape. The warm protons, on first examination, appear to be of sheath origin, displaying a similar energy distribution and accompanied by a tenuous warm population at M/Q=2 (which could be either solar wind alphas or molecular hydrogen ions of ionospheric origin). STATIC produces a weak ghost peak at M/Q=11-12 when observing molecular hydrogen ions, but not alphas, often allowing the instrument to distinguish the source of protons. Measurements show the warm protons are of ionospheric origin in the central tail and transition to sheath plasma in the umbra. Energetic (1-10 keV) pickup oxygen in the magnetotail is produced on the nightside, near the pole where the IMF convection electric field points toward the planet, the same hemisphere where sputtering occurs. When two spectral peaks are observed, these tailward-moving ions differ in direction by relatively small angles (about 20 degrees). These peaks can persist for tens of minutes indicating approximately time-stationary acceleration, and therefore acceleration in potential fields. Magnetotail structure and geometry can be inferred not only from the local magnetic field, but also from the measured electron distributions which indicate source

  19. Spin polarization of 34Al fragments produced by nucleon pickup at intermediate energies

    International Nuclear Information System (INIS)

    Turzo, K.; Himpe, P.; Borremans, D.; Mallion, S.; Neyens, G.; Vermeulen, N.; Yordanov, D.; Balabanski, D.L.; Belier, G.; Daugas, J.M.; Georgiev, G.; Oliveira de Santos, F.; Matea, I.; Stodel, Ch.; Penionzhkevich, Yu. E.

    2006-01-01

    The polarization of 34 Al fragments, produced by single neutron pickup from a 9 Be target by a 36 S projectile at 77.5 MeV/nucleon, have been observed at GANIL via the detection of resonantly destroyed β-asymmetry. The reaction-induced polarization is deduced using a tentative spin/parity assignment for the 34 Al ground state. A positive polarization was measured near the peak of the 34 Al yield curve. A kinematical model based on the spectator-participant model for projectile fragmentation reactions has been extended in order to take into account the features of pickup reactions, i.e., the picked-up nucleon having an average momentum equal to the Fermi momentum and aligned along the incident beam direction. The trend-line in the observed spin-orientation is very well reproduced by this model

  20. Ion cyclotron emission calculations using a 2D full wave numerical code

    International Nuclear Information System (INIS)

    Batchelor, D.B.; Jaeger, E.F.; Colestock, P.L.

    1987-01-01

    Measurement of radiation in the HF band due to cyclotron emission by energetic ions produced by fusion reactions or neutral beam injection promises to be a useful diagnostic on large devices which are entering the reactor regime of operation. A number of complications make the modelling and interpretation of such measurements difficult using conventional geometrical optics methods. In particular the long wavelength and lack of high directivity of antennas in this frequency regime make observation of a single path across the plasma into a viewing dump impractical. Pickup antennas effectively see the whole plasma and wall reflection effects are important. We have modified our 2D full wave ICRH code 2 to calculate wave fields due to a distribution of energetic ions in tokamak geometry. The radiation is modeled as due to an ensemble of localized source currents distributed in space. The spatial structure of the coherent wave field is then calculated including cyclotron harmonic damping as compared to the usual procedure of incoherently summing powers of individual radiators. This method has the advantage that phase information from localized radiating currents is globally retained so the directivity of the pickup antennas is correctly represented. Also standing waves and wall reflections are automatically included

  1. Charge-pickup of 238U at relativistic energies

    International Nuclear Information System (INIS)

    Rubehn, T.; Bassini, R.; Blaich, T.; Imme, G.; Iori, I.; Kunze, W.D.; Lindenstruth, V.; Lynen, U.; Moehlenkamp, T.; Moretto, L.G.; Ocker, B.; Pochodzalla, J.; Raciti, G.; Schuettauf, A.; Serfling, V.; Trautmann, W.; Trzcinski, A.; Verde, G.; Woerner, A.; Zude, E.; Zwieglinski, B.

    1995-10-01

    Cross sections for the charge-pickup of 238 U projectiles were measured at E/A=600 and 1000 MeV for seven different targets (Be, C, Al, Cu, In, Au and U). Events with two fission fragments with a sum charge of 93 in the exit channel were selected. Due to the significant excitation energy, the dominant part of produced Np nuclei fission instead of decaying to the ground state by evaporation. The observed cross sections can be well reproduced by intranuclear-cascade-plus-evaporation calculations and, therefore, confirm recent results that no exotic processes are needed to explain charge-pickup processes. (orig.)

  2. Evaluation of strip-line pick-up system for the SPS wideband transverse feedback system

    CERN Document Server

    Kotzian, G; Steinhagen, R J; Valuch, D; Wehrle, U

    2017-01-01

    The proposed SPS Wideband Transverse Feedback sys- tem requires a wide-band pick-up system to be able to de- tect intra-bunch motion within the SPS proton bunches, captured and accelerated in a 200 MHz bucket. We present the electro-magnetic design of transverse beam position pick-up options optimised for installation in the SPS and evaluate their performance reach with respect to direct time domain sampling of the intra-bunch motion. The analy- sis also discusses the achieved subsystem responses of the associated cabling with new low dispersion smooth wall coaxial cables, wide-band generation of intensity and posi- tion signals by means of 180 degree RF hybrids as well as passive techniques to electronically suppress the beam off- set signal, needed to optimise the dynamic range and posi- tion resolution of the planned digital intra-bunch feedback system.

  3. Water-Group Ion Distributions in the Mid-Cometosheath of Comet Halley

    Science.gov (United States)

    Huddleston, D. E.; Neugebauer, M.; Goldstein, B. E.

    1993-01-01

    In the mid-cometosheath of comet Halley (1-2x10^5 km from the nucleus) the center- of-mass plasma frame is approximately the bulk flow velocity of the cometary ions, and the Alfven wave speed is an appreciable fraction of the flow speed. Here, the peaks of the water-group ion distributions observed by the Giotto Ion Mass Spectrometer are at velocities consistently below the expected pickup speed. It is shown that this effect is consistent with the scattering of the new pickup ions onto a bispherical shell distribution. The model does not fit the data inside similar 1.2x10^5 km however, possibly as a result of the growing importance of collisions or the presence of other processes such as scattering on obliquely-propagating magnetosonic waves.

  4. Water group ion distributions in the midcometosheath of comet Halley

    Science.gov (United States)

    Huddleston, D. E.; Neugebauer, M.; Goldstein, Bruce E.

    1993-01-01

    In the midcometosheath of comet Halley (1 x 10(exp 5) to 2 x 10(exp 5) km from the nucleus) the center-of-mass plasma frame is approximately the bulk flow velocity of the cometary ions, and the Alfven wave speed is an appreciable fraction of the flow speed. Here, the peaks of the water group ion distributions observed by the Giotto ion mass spectrometer are at velocities consistently below the expected pickup speed. It is shown that this effect is consistent with the scattering of the new pickup ions onto a bispherical shell distribution. The model does not fit the data inside approximately 1.2 x 10(exp 5) km, however, possibly as a result of the growing importance of collisions or the presence of other processes such as scattering on obliquely propagating magnetosonic waves.

  5. Cometary water-group ions in the region surrounding Comet Giacobini-Zinner - Distribution functions and bulk parameter estimates

    Science.gov (United States)

    Staines, K.; Balogh, A.; Cowley, S. W. H.; Richardson, I. G.; Sanderson, T. R.; Tsurutani, B. T.

    1991-01-01

    The bulk parameters (number density and thermal energy density) of cometary water-group ions in the region surrounding Comet Giacobini-Zinner have been derived using data from the EPAS instrument on the ICE spacecraft. The derivation is based on the assumption that the pick-up ion distribution function is isotropic in the frame of the bulk flow, an approximation which has previously been shown to be reasonable within about 400,000 km of the comet nucleus along the spacecraft trajectory. The transition between the pick-up and mass-loaded regions occurs at the cometary shock, which was traversed at a cometocentric distance of about 100,000 km along the spacecraft track. Examination of the ion distribution functions in this region, transformed to the bulk flow frame, indicates the occurrence of a flattened distribution in the vicinity of the local pick-up speed, and a steeply falling tail at speeds above, which may be approximated as an exponential in ion speed.

  6. Observation of Magnetic Waves Excited by Newborn Interstellar Pickup He+ Observed by the Voyager 2 Spacecraft at 30 au

    Energy Technology Data Exchange (ETDEWEB)

    Argall, Matthew R.; Hollick, Sophia J.; Pine, Zackary B., E-mail: Matthew.Argall@unh.edu, E-mail: sjhollick@hotmail.com, E-mail: zbpine@gmail.com [Physics Department and Space Science Center, Morse Hall, University of New Hampshire, Durham, New Hampshire (United States); and others

    2017-11-01

    We report two observations of magnetic waves due to He{sup +} pickup ions observed by the Voyager 2 spacecraft in mid-1989 to demonstrate that such waves occur as far out as ∼30 au from the Sun. The observations are sufficiently far from planets, interplanetary shocks, and other possible sources of energetic particles to make newborn interstellar He{sup +} the only likely explanation for the source of the waves. Additionally, the low-frequency waves that might be expected for a variety of cometary pickup species are not seen. The events studied here were picked from a preliminary list of ∼300 events that were discovered based on polarization signatures in daily spectrograms of the magnetic field between 1977 and 1990. Analysis of those observations is ongoing. We present an analysis of these two observations using the same techniques we have employed for recently reported observations closer to the Sun.

  7. In-situ electrochemical impedance spectroscopy measurements of zirconium alloy oxide conductivity: Relationship to hydrogen pickup

    International Nuclear Information System (INIS)

    Couet, Adrien; Motta, Arthur T.; Ambard, Antoine; Livigni, Didier

    2017-01-01

    Highlights: • In-situ electrochemistry on zirconium alloys in 360 °C pure water show oxide layer resistivity changes during corrosion. • A linear relationship is observed between oxide resistivity and instantaneous hydrogen pickup fraction. • The resistivity of the oxide layer formed on Zircaloy-4 (and thus its hydrogen pickup fraction) is higher than on Zr-2.5Nb. - Abstract: Hydrogen pickup during nuclear fuel cladding corrosion is a critical life-limiting degradation mechanism for nuclear fuel. Following a program dedicated to zirconium alloys, corrosion, it has been hypothesized that oxide electronic resistivity determines hydrogen pickup. In-situ electrochemical impedance spectroscopy experiments were performed on Zircaloy-4 and Zr-2.5Nb alloys in 360 °C water. The oxide resistivity was measured as function of time. The results show that as the oxide resistivity increases so does the hydrogen pickup fraction. The resistivity of the oxide layer formed on Zircaloy-4 is higher than on Zr-2.5Nb, resulting in a higher hydrogen pickup fraction of Zircaloy-4, compared to Zr-2.5Nb.

  8. Structure of the Heliotail from Interstellar Boundary Explorer Observations: Implications for the 11-year Solar Cycle and Pickup Ions in the Heliosheath

    Energy Technology Data Exchange (ETDEWEB)

    Zirnstein, E. J.; McComas, D. J. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States); Heerikhuisen, J.; Zank, G. P.; Pogorelov, N. V. [Department of Space Science, University of Alabama in Huntsville, Huntsville, AL 35899 (United States); Funsten, H. O. [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Reisenfeld, D. B. [Department of Physics and Astronomy, University of Montana, Missoula, MT 59812 (United States); Schwadron, N. A., E-mail: ejz@princeton.edu [Southwest Research Institute, San Antonio, TX 78228 (United States)

    2017-02-20

    Interstellar Boundary Explorer ( IBEX ) measurements of energetic neutral atoms (ENAs) from the heliotail show a multi-lobe structure of ENA fluxes as a function of energy between ∼0.71 and 4.29 keV. Below ∼2 keV, there is a single structure of enhanced ENA fluxes centered near the downwind direction. Above ∼2 keV, this structure separates into two lobes, one north and one south of the solar equatorial plane. ENA flux from these two lobes can be interpreted as originating from the fast solar wind (SW) propagating through the inner heliosheath (IHS). Alternatively, a recently published model of the heliosphere suggests that the heliotail may split into a “croissant-like” shape, and that such a geometry could be responsible for the heliotail ENA feature. Here we present results from a time-dependent simulation of the heliosphere that produces a comet-like heliotail, and show that the 11-year solar cycle leads to the formation of ENA lobes with properties remarkably similar to those observed by IBEX . The ENA energy at which the north and south lobes appear suggests that the pickup ion (PUI) temperature in the slow SW of the IHS is ∼10{sup 7} K. Moreover, we demonstrate that the extinction of PUIs by charge-exchange is an essential process required to create the observed global ENA structure. While the shape and locations of the ENA lobes as a function of energy are well reproduced by PUIs that cross the termination shock, the results appear to be sensitive to the form of the distribution of PUIs injected in the IHS.

  9. Cation distribution in spinels and its effect on activity pick-up and passivation behaviour

    International Nuclear Information System (INIS)

    Subramanian, H.; Velmurugan, S.; Narasimhan, S.V.

    2000-01-01

    Spinels are found to be the major corrosion products in the primary heat transport system or nuclear reactors. These corrosion products are activated in the core and are picked up on the deposited corrosion product oxides, which lead to the radiation field buildup on out of core surfaces. In order to mitigate this phenomenon, it is extremely important to understand the structural changes that take place in a spinel in the primary heat transport system. Most of the spinels found in reactor systems are mixed spinels. Cation distribution in tetrahedral and octahedral sites of these spinels, which is temperature dependent, will affect the pickup of active metal ions from solution into these spinels. Distribution of cations in simple spinels was estimated by minimising the Gibbs energy change for the migration of ions between tetrahedral and octahedral sites, based on the assumption that it is the configurational entropy change for the process that dominates the distribution. Cation distribution for mixed spinels was also calculated using the same method. Energy demand for the exchange of an aqueous ion with these spinels has been estimated. (author)

  10. Pickup Protons: Comparisons using the Three-Dimensional MHD HHMS-PI model and Ulysses SWICS Measurements

    Science.gov (United States)

    Intriligator, Devrie S.; Detman, Thomas; Gloecker, George; Gloeckler, Christine; Dryer, Murray; Sun, Wei; Intriligator, James; Deehr, Charles

    2012-01-01

    We report the first comparisons of pickup proton simulation results with in situ measurements of pickup protons obtained by the SWICS instrument on Ulysses. Simulations were run using the three dimensional (3D) time-dependent Hybrid Heliospheric Modeling System with Pickup Protons (HHMS-PI). HHMS-PI is an MHD solar wind model, expanded to include the basic physics of pickup protons from neutral hydrogen that drifts into the heliosphere from the local interstellar medium. We use the same model and input data developed by Detman et al. (2011) to now investigate the pickup protons. The simulated interval of 82 days in 2003 2004, includes both quiet solar wind (SW) and also the October November 2003 solar events (the Halloween 2003 solar storms). The HHMS-PI pickup proton simulations generally agree with the SWICS measurements and the HHMS-PI simulated solar wind generally agrees with SWOOPS (also on Ulysses) measurements. Many specific features in the observations are well represented by the model. We simulated twenty specific solar events associated with the Halloween 2003 storm. We give the specific values of the solar input parameters for the HHMS-PI simulations that provide the best combined agreement in the times of arrival of the solar-generated shocks at both ACE and Ulysses. We show graphical comparisons of simulated and observed parameters, and we give quantitative measures of the agreement of simulated with observed parameters. We suggest that some of the variations in the pickup proton density during the Halloween 2003 solar events may be attributed to depletion of the inflowing local interstellar medium (LISM) neutral hydrogen (H) caused by its increased conversion to pickup protons in the immediately preceding shock.

  11. Development of a doorframe-typed swinging seedling pick-up device for automatic field transplantation

    Energy Technology Data Exchange (ETDEWEB)

    Han, H.; Mao, H.; Hu, J.; Tian, K.

    2015-07-01

    A doorframe-typed swing seedling pick-up device for automatic field transplanters was developed and evaluated in a laboratory. The device, consisting of a path manipulator and two grippers, can move the pins slowly to extract seedlings from the tray cells and return quickly to the pick-up point for the next extraction. The path manipulator was constructed with the creative design of type-Ⅱ mechanism combination in series. It consists of an oscillating guide linkage mechanism and a grooved globoidal cam mechanism. The gripper is a pincette-type mechanism using the pick-up pins to penetrate into the root mass for seedling extraction. The dynamic analysis of the designed seedling pick-up device was simulated with ADAMS software. Being the first prototype, various performance tests under local production conditions were conducted to find out the optimal machine operation parameters and transplant production conditions. As the gripper with multiple fine pins was moved by the swing pick-up device, it can effectively complete the transplanting work cycle of extracting, transferring, and discharging a seedling. The laboratory evaluation showed that the pick-up device equipped with two grippers can extract 80 seedlings/min with a 90% success and a 3% failure in discharging seedlings, using 42-day-old tomato plantlets. The quality of extracting seedlings was satisfactory. (Author)

  12. Single-Commodity Vehicle Routing Problem with Pickup and Delivery Service

    Directory of Open Access Journals (Sweden)

    Goran Martinovic

    2008-01-01

    Full Text Available We present a novel variation of the vehicle routing problem (VRP. Single commodity cargo with pickup and delivery service is considered. Customers are labeled as either cargo sink or cargo source, depending on their pickup or delivery demand. This problem is called a single commodity vehicle routing problem with pickup and delivery service (1-VRPPD. 1-VRPPD deals with multiple vehicles and is the same as the single-commodity traveling salesman problem (1-PDTSP when the number of vehicles is equal to 1. Since 1-VRPPD specializes VRP, it is hard in the strong sense. Iterative modified simulated annealing (IMSA is presented along with greedy random-based initial solution algorithm. IMSA provides a good approximation to the global optimum in a large search space. Experiment is done for the instances with different number of customers and their demands. With respect to average values of IMSA execution times, proposed method is appropriate for practical applications.

  13. AA precooling pickup

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    The freshly injected antiprotons, while circulating on the injection orbit, were subjected to fast stochastic "precooling" for several seconds (in momentum and in the vertical plane). This precooling pickup is being readied by Gerard Laurent for installation in its tank. Precooling PUs and kickers were of identical construction (except for the kickers having cooling circuits), with C-shaped ferrites sandwiched between C-shaped metal plates and couplers at the back of the C. For reasons explained in 8002234, they were also equipped with shutters which closed the open side of the C when there was beam on the injection orbit. For more on precooling see 8020234, 8004064.

  14. Enhanced Schottky signals from electron-cooled, coasting beams in a heavy-ion storage ring

    Energy Technology Data Exchange (ETDEWEB)

    Krantz, C., E-mail: claude.krantz@mpi-hd.mpg.d [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany); Blaum, K.; Grieser, M. [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany); Litvinov, Yu.A. [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany); GSI Helmholtzzentrum fuer Schwerionenforschung, Planckstrasse 1, D-64291 Darmstadt (Germany); Repnow, R.; Wolf, A. [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany)

    2011-02-11

    Measurements at the Test Storage Ring of the Max-Planck-Institut fuer Kernphysik in Heidelberg (Germany) have shown that the signal amplitude induced in a Schottky-noise pickup electrode by a coasting electron-cooled ion beam can be greatly enhanced by exposure of the latter to a perturbing radiofrequency signal which is detuned from the true beam revolution frequency. The centre frequencies obtained from harmonic analysis of the observed pickup signal closely follow those imposed on the ions by the electron cooling force. The phenomenon can be exploited to measure the true revolution frequency of ion beams of very low intensity, whose pure Schottky noise is too weak to be measurable under normal circumstances.

  15. Solenoid pick-up problem in the CREN-K Triga Mark 2 reactor

    International Nuclear Information System (INIS)

    Malu wa Kalenga; Kobakozete Itono; Diazengwa Mpaka; Mampaka Mana Mouiny; Itio Momba

    1981-01-01

    During a lazy susan forty irradiation tube inspection with the specimen lifting device, the solenoid-operated specimen pick-up tool happened to be locked in the number fourteen position loading tube. The present paper describes the successful experiment which was carried out to solve a potential damaging situation for the safe and useful operation of the reactor. The first step in the investigation process was to ascertain what has indeed occurred in the reactor core to avoid any ill advised step which will worsen the situation. The alternatives were the following: a) The specimen tube was not lined with the loading tube; b) The lazy susan was not working properly due example to the fact that a roll pin in a drive shaft coupling inside the drive shaft tube has been broken; c) The pick-up tool has produced through the cleanout hole in the bottom of the specimen tube and engage the hole; d) The pick-up tool might have slided most of the way between the lazy susan and its housing. By moving up and down the pick-up tool and rotating back and forth the lazy susan it was possible to come to the conclusion that alternative c) was the most likely. It was not possible to release the pick-up tool because its engaging arms could not be activated as was often the case when lifting aluminium container

  16. Solenoid pick-up problem in the CREN-K Triga Mark 2 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Malu wa Kalenga; Kobakozete Itono; Diazengwa Mpaka; Mampaka Mana Mouiny; Itio Momba (Commissariat des Sciences Nucleaires, Kinshasa (Zaire). Centre Regional d' Etudes Nucleaires)

    1981-01-01

    During a lazy susan forty irradiation tube inspection with the specimen lifting device, the solenoid-operated specimen pick-up tool happened to be locked in the number fourteen position loading tube. The present paper describes the successful experiment which was carried out to solve a potential damaging situation for the safe and useful operation of the reactor. The first step in the investigation process was to ascertain what has indeed occurred in the reactor core to avoid any ill advised step which will worsen the situation. The alternatives were the following: a) The specimen tube was not lined with the loading tube; b) The lazy susan was not working properly due example to the fact that a roll pin in a drive shaft coupling inside the drive shaft tube has been broken; c) The pick-up tool has produced through the cleanout hole in the bottom of the specimen tube and engage the hole; d) The pick-up tool might have slided most of the way between the lazy susan and its housing. By moving up and down the pick-up tool and rotating back and forth the lazy susan it was possible to come to the conclusion that alternative c) was the most likely. It was not possible to release the pick-up tool because its engaging arms could not be activated as was often the case when lifting aluminium container.

  17. Developments at an electrostatic cryogenic storage ring for electron-cooled keV energy ion beams

    International Nuclear Information System (INIS)

    Vogel, Stephen

    2016-01-01

    This work is devoted to final setup activities and the commissioning of an electrostatic cryogenic storage ring (CSR) at the Max Planck Institute for Nuclear Physics (MPIK) in Heidelberg. The first cryogenic operation of CSR in 2015 has been documented and characterized using a set of non-destructive beam diagnostic tools developed within this work. These are (1) the current pick-up system for the determination of the current of the stored ion beam and its velocity, (2) a position pick-up system for measuring the transverse position of the ion beam center at six symmetric locations of the storage ring circumference, and (3) a Schottky pick-up system for the monitoring of coasting ion beams. Despite the requirements imposed by the cryogenic operation, the developed diagnostic system demonstrated its full functionality. First characterizations of the storage ring properties and the performance of the diagnostic system are presented. Based on previous work, an electron cooling system for CSR has been developed and largely realized. With the implementation into CSR in 2016, the electron cooler will enhance the storage ring into a unique experimental facility for electron-ion collision studies. With this CSR is on the track to become the first cryogenic storage ring featuring actively cooled ion beams.

  18. Analytical model of tilted driver–pickup coils for eddy current nondestructive evaluation

    Science.gov (United States)

    Cao, Bing-Hua; Li, Chao; Fan, Meng-Bao; Ye, Bo; Tian, Gui-Yun

    2018-03-01

    A driver-pickup probe possesses better sensitivity and flexibility due to individual optimization of a coil. It is frequently observed in an eddy current (EC) array probe. In this work, a tilted non-coaxial driver-pickup probe above a multilayered conducting plate is analytically modeled with spatial transformation for eddy current nondestructive evaluation. Basically, the core of the formulation is to obtain the projection of magnetic vector potential (MVP) from the driver coil onto the vector along the tilted pickup coil, which is divided into two key steps. The first step is to make a projection of MVP along the pickup coil onto a horizontal plane, and the second one is to build the relationship between the projected MVP and the MVP along the driver coil. Afterwards, an analytical model for the case of a layered plate is established with the reflection and transmission theory of electromagnetic fields. The calculated values from the resulting model indicate good agreement with those from the finite element model (FEM) and experiments, which validates the developed analytical model. Project supported by the National Natural Science Foundation of China (Grant Nos. 61701500, 51677187, and 51465024).

  19. Analysis of Pick-Up Development in Punching

    DEFF Research Database (Denmark)

    Olsson, David Dam; Bay, Niels; Andreasen, Jan Lasson

    2002-01-01

    The development of pick-up of work piece material on the punch surface with increasing number of strokes during punching of stainless steel sheet is investigated applying Scanning Electron Microscopy (SEM), 3D roughness mapping and measurements of the backstroke force. It is found that pick...

  20. Trajectory bending and energy spreading of charged ions in time-of-flight telescopes used for ion beam analysis

    International Nuclear Information System (INIS)

    Laitinen, Mikko; Sajavaara, Timo

    2014-01-01

    Carbon foil time pick-up detectors are widely used in pairs in ion beam applications as time-of-flight detectors. These detectors are suitable for a wide energy range and for all ions but at the lowest energies the tandem effect limits the achievable time of flight and therefore the energy resolution. Tandem effect occurs when an ion passes the first carbon foil of the timing detector and its charge state is changed. As the carbon foil of the first timing detector has often a non-zero voltage the ion can accelerate or decelerate before and after the timing detector. The combination of different charge state properties before and after the carbon foil now induces spread to the measured times of flight. We have simulated different time pick-up detector orientations, voltages, ions and ion energies to examine the tandem effect in detail and found out that the individual timing detector orientation and the average ion charge state have a very small influence to the magnitude of the tandem effect. On the other hand, the width of the charge state distribution for particular ion and energy in the first carbon foil, and the carbon foil voltage contributes linearly to the magnitude of the tandem effect. In the simulations low energy light ion trajectories were observed to bend in the electric fields of the first timing gate, and the magnitude of this bending was studied. It was found out that 50–150 keV proton trajectories can even bend outside the second timing gate

  1. Direct photons in heavy-ion collisions

    Energy Technology Data Exchange (ETDEWEB)

    Baeuchle, Bjoern

    2010-12-13

    Direct photon emission from heavy-ion collisions has been calculated and compared to available experimental data. Three different models have been combined to extract direct photons from different environments in a heavy-ion collision: Thermal photons from partonic and hadronic matter have been extracted from relativistic, non-viscous 3+1-dimensional hydrodynamic calculations. Thermal and non-thermal photons from hadronic interactions have been calculated from relativistic transport theory. The impact of different physics assumptions about the thermalized matter has been studied. The models used for the determination of photons from both hydrodynamic and transport calculations have been elucidated and their numerical properties tested. The origin of direct photons, itemised by emission stage, emission time, channel and baryon number density, has been investigated for various systems, as have the transverse momentum spectra and elliptic flow patterns of direct photons. Taking into account the full (vacuum) spectral function of the rho-meson decreases the direct photon emission by approximately 10% at low photon transverse momentum. In all systems that have been considered -- heavy-ion collisions at E{sub lab}=35 AGeV and 158 AGeV, (s{sub NN}){sup 1/2}=62.4 GeV, 130 GeV and 200 GeV -- thermal emission from a system with partonic degrees of freedom is greatly enhanced over that from hadronic systems, while the difference between the direct photon yields from a viscous and a non-viscous hadronic system (transport vs. hydrodynamics) is found to be very small. Predictions for direct photon emission in central U+U-collisions at 35 AGeV have been made. (orig.)

  2. Direct photons in heavy-ion collisions

    International Nuclear Information System (INIS)

    Baeuchle, Bjoern

    2010-01-01

    Direct photon emission from heavy-ion collisions has been calculated and compared to available experimental data. Three different models have been combined to extract direct photons from different environments in a heavy-ion collision: Thermal photons from partonic and hadronic matter have been extracted from relativistic, non-viscous 3+1-dimensional hydrodynamic calculations. Thermal and non-thermal photons from hadronic interactions have been calculated from relativistic transport theory. The impact of different physics assumptions about the thermalized matter has been studied. The models used for the determination of photons from both hydrodynamic and transport calculations have been elucidated and their numerical properties tested. The origin of direct photons, itemised by emission stage, emission time, channel and baryon number density, has been investigated for various systems, as have the transverse momentum spectra and elliptic flow patterns of direct photons. Taking into account the full (vacuum) spectral function of the rho-meson decreases the direct photon emission by approximately 10% at low photon transverse momentum. In all systems that have been considered -- heavy-ion collisions at E lab =35 AGeV and 158 AGeV, (s NN ) 1/2 =62.4 GeV, 130 GeV and 200 GeV -- thermal emission from a system with partonic degrees of freedom is greatly enhanced over that from hadronic systems, while the difference between the direct photon yields from a viscous and a non-viscous hadronic system (transport vs. hydrodynamics) is found to be very small. Predictions for direct photon emission in central U+U-collisions at 35 AGeV have been made. (orig.)

  3. Three-dimensional magnetic nanoparticle imaging using small field gradient and multiple pickup coils

    Energy Technology Data Exchange (ETDEWEB)

    Sasayama, Teruyoshi, E-mail: sasayama@sc.kyushu-u.ac.jp; Tsujita, Yuya; Morishita, Manabu; Muta, Masahiro; Yoshida, Takashi; Enpuku, Keiji

    2017-04-01

    We propose a magnetic particle imaging (MPI) method based on third harmonic signal detection using a small field gradient and multiple pickup coils. First, we developed a system using two pickup coils and performed three-dimensional detection of two magnetic nanoparticle (MNP) samples, which were spaced 15 mm apart. In the experiments, an excitation field strength of 1.6 mT was used at an operating frequency of 3 kHz. A DC gradient field with a typical value of 0.2 T/m was also used to produce the so-called field-free line. A third harmonic signal generated by the MNP samples was detected using the two pickup coils, and the samples were then mechanically scanned to obtain field maps. The field maps were subsequently analyzed using the nonnegative least squares method to obtain three-dimensional position information for the MNP samples. The results show that the positions of the two MNP samples were estimated with good accuracy, despite the small field gradient used. Further improvement in MPI performance will be achieved by increasing the number of pickup coils used. - Highlights: • 3D magnetic particle imaging system combining field-free line and two pickup coils. • Imaging method based on third harmonic signal detection and small field gradient. • Nonnegative least squares method for 3D magnetic nanoparticle image reconstruction. • High spatial resolution despite use of small field gradient.

  4. Carbon monoxide poisoning in children riding in the back of pickup trucks.

    Science.gov (United States)

    Hampson, N B; Norkool, D M

    OBJECTIVE - To describe the case characteristics of a series of children poisoned with carbon monoxide while traveling in the back of pickup trucks. DESIGN - Pediatric cases referred for treatment of carbon monoxide poisoning with hyperbaric oxygen between 1986 and 1991 were reviewed. Those cases that occurred during travel in the back of pickup trucks were selected. Clinical follow-up by telephone interview ranged from 2 to 55 months. SETTING - A private, urban, tertiary care center in Seattle, Wash. PATIENTS - Twenty children ranging from 4 to 16 years of age. INTERVENTION - All patients were treated with hyperbaric oxygen. MAIN OUTCOME MEASURES - Characteristics of the poisoning incident and clinical patient outcome. RESULTS - Of 68 pediatric patients treated for accidental carbon monoxide poisoning, 20 cases occurred as children rode in the back of pickup trucks. In 17 of these, the children were riding under a rigid closed canopy on the rear of the truck, while three episodes occurred as children rode beneath a tarpaulin. Average carboxyhemoglobin level on emergency department presentation was 18.2% +/- 2.4% (mean +/- SEM; range, 1.6% to 37.0%). Loss of consciousness occurred in 15 of the 20 children. One child died of cerebral edema, one had permanent neurologic deficits, and 18 had no recognizable sequelae related to the episode. In all cases, the truck exhaust system had a previously known leak or a tail pipe that exited at the rear rather than at the side of the pickup truck. CONCLUSIONS - Carbon monoxide poisoning is a significant hazard for children who ride in the back of pickup trucks. If possible, this practice should be avoided.

  5. Hydrogen pickup and redistribution in alpha-annealed Zircaloy-4

    International Nuclear Information System (INIS)

    Kammenzind, B.F.; Franklin, D.G.; Duffin, W.J.; Peters, H.R.

    1996-01-01

    Zircaloy-4, which is widely used as a core structural material in Pressurized-Water Reactors (PWR), picks up hydrogen during service. Hydrogen solubility in Zircaloy-4 is low and hydrides precipitate after the Zircaloy-4 matrix becomes supersaturated with hydrogen. These hydrides embrittle the Zircaloy-4. To study hydrogen pickup and concentration, a postirradiation nondestructive radiographic technique for measuring hydrogen concentration was developed and qualified. Experiments on hydrogen pickup were conducted in the Advanced Test Reactor (ATR). Ex-reactor tests were conducted to determine the conditions for which hydrogen would dissolve, migrate, and precipitate. Finally, a phenomenological model for hydrogen diffusion was indexed to the data. This presentation describes the equipment and the model, presents the results of experiments, and compares the model predictions to experimental results

  6. Influence of the Interplanetary Convective Electric Field on the Distribution of Heavy Pickup Ions Around Mars

    Science.gov (United States)

    Johnson, B. C.; Liemohn, M. W.; Fränz, M.; Ramstad, R.; Stenberg Wieser, G.; Nilsson, H.

    2018-01-01

    This study obtains a statistical representation of 2-15 keV heavy ions outside of the Martian-induced magnetosphere and depicts their organization by the solar wind convective electric field (ESW). The overlap in the lifetime of Mars Global Surveyor (MGS) and Mars Express (MEX) provides a period of nearly three years during which magnetometer data from MGS can be used to estimate the direction of ESW in order to better interpret MEX ion data. In this paper we use MGS estimates of ESW to express MEX ion measurements in Mars-Sun-Electric field (MSE) coordinates. A new methodological technique used in this study is the limitation of the analysis to a particular instrument mode for which the overlap between proton contamination and plume observations is rare. This allows for confident energetic heavy ion identification outside the induced magnetosphere boundary. On the dayside, we observe high count rates of 2-15 keV heavy ions more frequently in the +ESW hemisphere (+ZMSE) than in the -ESW hemisphere, but on the nightside the reverse asymmetry was found. The results are consistent with planetary origin ions being picked up by the solar wind convective electric field. Though a field of view hole hinders quantification of plume fluxes and velocity space, this new energetic heavy ion identification technique means that Mars Express should prove useful in expanding the time period available to assess general plume loss variation with drivers.

  7. A model for hydrogen pickup for BWR cladding materials

    International Nuclear Information System (INIS)

    Hede, G.; Kaiser, U.

    2001-01-01

    It has been observed that rod elongation is driven by the hydrogen pickup but not by corrosion as such. Based on this a non-destructive method to determine clad hydrogen concentration has been developed. The method is based on the observation that there are three different mechanisms behind the rod growth: the effect of neutron irradiation on the Zircaloy microstructure, the volume increase of the cladding as an effect of hydride precipitation and axial pellet-cladding-mechanical-interaction (PCMI). The derived correlation is based on the experience of older cladding materials, inspected at hot-cell laboratories, that obtained high hydrogen levels (above 500 ppm) at lower burnup (assembly burnup below 50 MWd/kgU). Now this experience can be applied, by interpolation, on more modern cladding materials with a burnup beyond 50 MWd/kgU by analysis of the rod growth database of the respective cladding materials. Hence, the method enables an interpolation rather than an extrapolation of present day hydrogen pickup database, which improves the reliability and accuracy. Further, one can get a good estimate of the hydrogen pickup during an ongoing outage based on a non-destructive method. Finally, rod growth measurements are normally performed for a large population of rods, hence giving a good statistics compared to examination of a few rods at a hot cell. (author)

  8. Lifetime measurements in an electrostatic ion beam trap using image charge monitoring

    International Nuclear Information System (INIS)

    Rahinov, Igor; Toker, Yoni; Heber, Oded; Rappaport, Michael; Zajfman, Daniel; Strasser, Daniel; Schwalm, Dirk

    2012-01-01

    A technique for mass-selective lifetime measurements of keV ions in a linear electrostatic ion beam trap is presented. The technique is based on bunching the ions using a weak RF potential and non-destructive ion detection by a pick-up electrode. This method has no mass-limitation, possesses the advantage of inherent mass-selectivity, and offers a possibility of measuring simultaneously the lifetimes of different ion species with no need for prior mass-selection.

  9. Cometary ion instabilities in the solar wind

    Czech Academy of Sciences Publication Activity Database

    Matteini, L.; Schwartz, S. J.; Hellinger, Petr

    2015-01-01

    Roč. 119, Special Is. (2015), s. 3-12 ISSN 0032-0633 R&D Projects: GA ČR GA15-10057S Institutional support: RVO:67985815 Keywords : cometary plasma * hybrid simulations * pick-up ion instabilities Subject RIV: BN - Astronomy, Celestial Mechanics, Astrophysics Impact factor: 1.942, year: 2015

  10. Tracked "Pick-Up" Ultrasound for Robot-Assisted Minimally Invasive Surgery.

    Science.gov (United States)

    Schneider, Caitlin; Nguan, Christopher; Rohling, Robert; Salcudean, Septimiu

    2016-02-01

    We present a novel "pick-up" ultrasound transducer for intraabdominal robot-assisted minimally invasive surgery. Such a "pick-up" ultrasound transducer is inserted through an abdominal incision at the beginning of the procedure and remains in the abdominal cavity throughout, eliminating the need for a dedicated port or a patient bedside surgical assistant. The transducer has a handle that can be grasped in a repeatable manner using a da Vinci Prograsp tool, allowing the transducer to be accurately manipulated by the surgeon using the da Vinci Robot. This is one way to enable 3-D tracking of the transducer, and, thus, mapping of the vasculature. The 3-D vascular images can be used to register preoperative CT to intraoperative camera images. To demonstrate the feasibility of the approach, we use an ultrasound vessel phantom to register a CT surface model to extracted ultrasound vessel models. The 3-D vascular phantom images are generated by segmenting B-mode images and tracking the pick-up ultrasound transducer with the da Vinci kinematics, internal electromagnetic sensor, or visible fiducials suitable for camera tracking. Reconstruction results using da Vinci kinematics for tracking give a target registration error of 5.4 ± 1.7 mm.

  11. An assessment of the waterside corrosion and hydrogen pick-up in the zircaloy-2 pressure tubes of PHWR

    International Nuclear Information System (INIS)

    Sah, D.N.

    1992-01-01

    In view of the deleterious effect of hydriding on the operating life of zircaloy-2 pressure tubes in PHWRs there is an urgent need for the assessment of the status of the pressure tubes with respect to corrosion and hydrogen pick-up in the operating PHWRs. A model has been developed for analysing the waterside corrosion and hydrogen pick-up in the zircaloy-2 pressure tubes under reactor operating conditions. This model predicts the axial profiles of oxide layer thickness and hydrogen pick-up in the pressure tubes as a function of the operating time of the reactor. The prediction of hydrogen pick-up by the model in the F-10 pressure tube of RAPS-I have been found to be in good agreement with the measured value of hydrogen content. This report gives a brief description of the model and its predictions on the present status of hydrogen pick-up in the pressure tubes of lead reactor RAPS-II. (author). 6 refs., 5 figs., 2 tabs

  12. Some calculated (p,α) cross-sections using the alpha particle knock-on and triton pick-up reaction mechanisms: An optimisation of the single-step Feshbach-Kerman-Koonin (FKK) theory

    Energy Technology Data Exchange (ETDEWEB)

    Olise, Felix S.; Ajala, Afis; Olamiyl, Hezekiah B. [Dept. of Physics and Engineering Physics, Obafemi Awolowo University, Ile-Ife (Nigeria)

    2016-04-15

    The Feshbach-Kerman-Koonin (FKK) multi-step direct (MSD) theory of pre-equilibrium reactions has been used to compute the single-step cross-sections for some (p,α) reactions using the knock-on and pick-up reaction mechanisms at two incident proton energies. For the knock-on mechanism, the reaction was assumed to have taken place by the direct ejection of a preformed alpha cluster in a shell-model state of the target. But the reaction was assumed to have taken place by the pick-up of a preformed triton cluster (also bound in a shell-model state of the target core) by the incident proton for the pick-up mechanism. The Yukawa forms of potential were used for the proton-alpha (for the knock-on process) and proton-triton (for the pick-up process) interaction and several parameter sets for the proton and alpha-particle optical potentials. The calculated cross-sections for both mechanisms gave satisfactory fits to the experimental data. Furthermore, it has been shown that some combinations of the calculated distorted wave Born approximation cross-sections for the two reaction mechanisms in the FKK MSD theory are able to give better fits to the experimental data, especially in terms of range of agreement. In addition, the theory has been observed to be valid over a wider range of energy.

  13. Some Calculated (p,α Cross-Sections Using the Alpha Particle Knock-On and Triton Pick-Up Reaction Mechanisms: An Optimisation of the Single-Step Feshbach–Kerman–Koonin (FKK Theory

    Directory of Open Access Journals (Sweden)

    Felix S. Olise

    2016-04-01

    Full Text Available The Feshbach–Kerman–Koonin (FKK multi-step direct (MSD theory of pre-equilibrium reactions has been used to compute the single-step cross-sections for some (p,α reactions using the knock-on and pick-up reaction mechanisms at two incident proton energies. For the knock-on mechanism, the reaction was assumed to have taken place by the direct ejection of a preformed alpha cluster in a shell-model state of the target. But the reaction was assumed to have taken place by the pick-up of a preformed triton cluster (also bound in a shell-model state of the target core by the incident proton for the pick-up mechanism. The Yukawa forms of potential were used for the proton-alpha (for the knock-on process and proton-triton (for the pick-up process interaction and several parameter sets for the proton and alpha-particle optical potentials. The calculated cross-sections for both mechanisms gave satisfactory fits to the experimental data. Furthermore, it has been shown that some combinations of the calculated distorted wave Born approximation cross-sections for the two reaction mechanisms in the FKK MSD theory are able to give better fits to the experimental data, especially in terms of range of agreement. In addition, the theory has been observed to be valid over a wider range of energy.

  14. Uptake of methanol on mixed HNO3/H2O clusters: An absolute pickup cross section

    Science.gov (United States)

    Pysanenko, A.; Lengyel, J.; Fárník, M.

    2018-04-01

    The uptake of atmospheric oxidized organics on acid clusters is relevant for atmospheric new particle formation. We investigate the pickup of methanol (CH3OH) on mixed nitric acid-water clusters (HNO3)M(H2O)N by a combination of mass spectrometry and cluster velocity measurements in a molecular beam. The mass spectra of the mixed clusters exhibit (HNO3)m(H2O)nH+ series with m = 0-3 and n = 0-12. In addition, CH3OH.(HNO3)m(H2O)nH+ series with very similar patterns appear in the spectra after the methanol pickup. The velocity measurements prove that the undoped (HNO3)m(H2O)nH+ mass peaks in the pickup spectra originate from the neutral (HNO3)M(H2O)N clusters which have not picked up any CH3OH molecule, i.e., methanol has not evaporated upon the ionization. Thus the fraction of the doped clusters can be determined and the mean pickup cross section can be estimated, yielding σs ¯ ≈ 20 Å2. This is compared to the lower estimate of the mean geometrical cross section σg ¯ ≈ 60 Å2 obtained from the theoretical cluster geometries. Thus the "size" of the cluster corresponding to the methanol pickup is at least 3-times smaller than its geometrical size. We have introduced a method which can yield the absolute pickup cross sections relevant to the generation and growth of atmospheric aerosols, as illustrated in the example of methanol and nitric acid clusters.

  15. Direct processes in heavy ion reactions

    International Nuclear Information System (INIS)

    Bunakov, V.E.; Zagrebaev, V.I.

    1983-01-01

    Direct processes in heavy ion reactions are investigated. Relative theoretical contributions in the inclusive spectrum of α particles on processes of stripping breakup and inelastic breakup are estimated using the 22 Ne+ 181 Ta reaction as an example. The consideration is performed taking into account Coulomb and nuclear distortions in the inlet and outlet ion channels. It is shown that the hard edge of α spectrum and its maximum are well described by peripheral direct processes. The hard spectrum edge is conditioned by the pure process of ''incomplete fussion'' bringing about the production af a compound nucleus. The main part of inclusive spectrum is conditioned by reactions of inelastic and elastic breakup not connected with the production of a compound nucleus

  16. One-nucleon pickup reactions and compound-nuclear decays

    Science.gov (United States)

    Escher, J. E.; Burke, J. T.; Casperson, R. J.; Hughes, R. O.; Scielzo, N. D.

    2018-05-01

    One-nucleon transfer reactions, long used as a tool to study the structure of nuclei, are potentially valuable for determining reaction cross sections indirectly. This is significant, as many reactions of interest to astrophysics and other applications involve short-lived isotopes and cannot be measured directly. We describe a procedure for obtaining constraints for calculations of neutron capture cross sections using observables from experiments with transfer reactions. As a first step toward demonstrating the method, we outline the theory developments used to properly describe the production of the compound nucleus 88Y* via the one-nucleon pickup reaction 89Y(p,d)88Y* and test the description with data from a recent experiment. We indicate how this development can be used to extract the unknown 87Y(n,γ) cross section from 89Y(p,dγ) data. The example illustrates a more generally applicable method for determining unknown cross sections via a combination of theory and transfer (or inelastic scattering) experiments.

  17. Future directions in electron--ion collision physics

    International Nuclear Information System (INIS)

    Reed, K.J.; Griffin, D.C.

    1992-01-01

    This report discusses the following topics: Summary of session on synergistic co-ordination of theory and experiment; synergism between experiment and theory in atomic physics; comparison of theory and experiment for electron-ion excitation and ionization; summary of session on new theoretical and computational methods; new theoretical and computational methods-r-matrix calculations; the coulomb three-body problem: a progress report; summary of session on needs and applications for electron-ion collisional data; electron-ion collisions in the plasma edge; needs and applications of theoretical data for electron impact excitation; summary of session on relativistic effects, indirect effects, resonance, etc; direct and resonant processes in electron-ion collisions; relativistic calculations of electron impact ionization and dielectronic recombination cross section for highly charged ions; electron-ion recombination in the close-coupling approximation; modified resonance amplitudes with strongly correlated channels; a density-matrix approach to the broadening of spectral lines by autoionization, radiative transitions and electron-ion collisions; towards a time-dependent description of electron-atom/ion collisions two electron systems; and comments on inclusion of the generalized bright interaction in electron impact excitation of highly charged ions

  18. High-lying neutron hole strengths observed in pick-up reactions

    International Nuclear Information System (INIS)

    Gales, S.

    1980-01-01

    Neutron-hole states in orbits well below the Fermi surface have been observed in a number of medium-heavy nuclei from A=90 to 209 using one nucleon pick-up reactions. The excitation energies, angular distributions of such broad and enhanced structures will be discussed. The fragmentation of the neutron-hole strengths as well as the spreading of such simple mode of excitations into more complex states are compared to recent calculations within the quasiparticle-phonon or the single particle-vibration coupling nuclear models. We report on recent measurements of J for inner-hole states in 89 Zr and 115 Sn 119 Sn using the analyzing power of the (p,d) and (d,t) reactions. Large enhancement of cross-sections are observed at high excitation energy in the study of the (p,t) reactions on Zr, Cd, Sn, Te and Sm isotopes. The systematic features of such high-lying excitation are related to the ones observed in one neutron pick-up experiments. The origin of such concentration of two neutron-hole strengths in Cd and Sn isotopes will be discussed. Preliminary results obtained in the study of the (α, 6 He) reaction at 218 MeV incident energy on 90 Zr, 118 Sn and 208 Pb targets are presented and compared to the (p,t) results. Finally the properties of hole-analog states populated in neutron pick-up reactions (from 90 Zr to 208 Pb) will be presented

  19. Pickup ion processes associated with spacecraft thrusters: Implications for solar probe plus

    Energy Technology Data Exchange (ETDEWEB)

    Clemens, Adam, E-mail: a.j.clemens@qmul.ac.uk; Burgess, David [School of Physics and Astronomy, Queen Mary University of London, London (United Kingdom)

    2016-03-15

    Chemical thrusters are widely used in spacecraft for attitude control and orbital manoeuvres. They create an exhaust plume of neutral gas which produces ions via photoionization and charge exchange. Measurements of local plasma properties will be affected by perturbations caused by the coupling between the newborn ions and the plasma. A model of neutral expansion has been used in conjunction with a fully three-dimensional hybrid code to study the evolution and ionization over time of the neutral cloud produced by the firing of a mono-propellant hydrazine thruster as well as the interactions of the resulting ion cloud with the ambient solar wind. Results are presented which show that the plasma in the region near to the spacecraft will be perturbed for an extended period of time with the formation of an interaction region around the spacecraft, a moderate amplitude density bow wave bounding the interaction region and evidence of an instability at the forefront of the interaction region which causes clumps of ions to be ejected from the main ion cloud quasi-periodically.

  20. Vehicle test report: Battronic pickup truck

    Science.gov (United States)

    Price, T. W.; Shain, T. W.; Freeman, R. J.; Pompa, M. F.

    1982-01-01

    An electric pickup truck was tested to characterize certain parameters and to provide baseline data that can be used for the comparison of improved batteries that may be incorporated into the vehicle at a later time. The vehicle tests were concentrated on the electrical drive subsystem; i.e., the batteries, controller, and motor. The tests included coastdowns to characterize the road load and range evaluations for both cyclic and constant speed conditions. A qualitative evaluation of the vehicle's performance was made by comparing its constant speed range performance with other vehicles.

  1. Slot-type pickup/kicker for AA stochastic cooling

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    A "slotted transmission line" was used for both pickups and kickers of the stochastic cooling systems of the AA. They served for the cooling of the high-density antiproton stack, in momentum and both transverse planes. In the beginning in a single band, 1-2 GHz, later in 2 bands, 2-4 and 4-8 GHz. See also 7906190, 7906193.

  2. Beam position monitor R&D for keV ion beams

    CERN Document Server

    Naveed, S; Nosych, A; Søby,L

    2013-01-01

    Beams of cooled antiprotons at keV energies shall be provided by the Ultra-low energy Storage Ring (USR) at the Facility for Low energy Antiproton and Ion Research (FLAIR) and the Extra Low ENergy Antiproton ring (ELENA) at CERN's Antiproton Decelerator (AD) facility. Both storage rings put challenging demands on the beam position monitoring (BPM) system as their capacitive pick-ups should be capable of determining the beam position of beams at low intensities and low velocities, close to the noise level of state-of-the-art electronics. In this contribution we describe the design and anticipated performance of BPMs for low-energy ion beams with a focus on the ELENA orbit measurement systems. We also present the particular challenges encountered in the numerical simulation of pickup response at very low beta values. Finally, we provide an outlook on how the implementation of faster algorithms for the simulation of BPM characteristics could potentially help speed up such studies considerably.

  3. Study of the continuum in heavy ion inelastic spectra by light particle coincidence measurements

    International Nuclear Information System (INIS)

    Scarpaci, J.A.; Blumenfeld, Y.; Chomaz, P.; Frascaria, N.; Garron, J.P.; Roynette, J.C.; Suomijarvi, T.; Van der Woude, A.; Alamanos, N.; Fernandez, B.; Gillibert, A.; Van der Woude, A.; Lepine, A.

    1990-01-01

    The continuum in heavy ion inelastic spectra contains, in addition to the excitation of target nucleus states, contributions from pick-up break-up and knock out reactions. In the case of the 40 Ca + 40 Ca collision at 50 MeV/N these contributions are separated and their relative importance assessed by the measurement of light charged particles in coincidence with the inelastically scattered fragments. The pick-up break-up contribution is found to make up less than half of the cross section at high excitation energies, conversely, the knock out process is important

  4. Musical instrument pickup based on a laser locked to an optical fiber resonator.

    Science.gov (United States)

    Avino, Saverio; Barnes, Jack A; Gagliardi, Gianluca; Gu, Xijia; Gutstein, David; Mester, James R; Nicholaou, Costa; Loock, Hans-Peter

    2011-12-05

    A low-noise transducer based on a fiber Fabry-Perot (FFP) cavity was used as a pickup for an acoustic guitar. A distributed feedback (DFB) laser was locked to a 25 MHz-wide resonance of the FFP cavity using the Pound-Drever-Hall method. The correction signal was used as the audio output and was preamplified and sampled at up to 96 kHz. The pickup system is largely immune against optical noise sources, exhibits a flat frequency response from the infrasound region to about 25 kHz, and has a distortion-free audio output range of about 50 dB.

  5. The role of charge-exchange cross-section for pickup protons and neutrals in the inner heliosheath

    Science.gov (United States)

    Chalov, S. V.

    2018-06-01

    The process of deceleration of the solar wind downstream of the termination shock is studied on the basis of a one-dimensional multi-component model. It is assumed that the solar wind consists of thermal protons, electrons and interstellar pickup protons. The protons interact with interstellar hydrogen atoms by charge-exchange. Two cases are considered. In the first one, the charge-exchange cross-section for thermal protons and hydrogen atoms is the same as for pickup protons and atoms. Under this condition, there is a strong dependence of the solar wind velocity on the downstream temperature of pickup protons. When the proton temperature is close to 10 keV, the change in the velocity with the distance from the termination shock is similar to that measured on the Voyager 1 spacecraft: linear velocity decrease is accompanied by an extended transition region with near-zero velocity. However, with a more careful approach to the choice of the charge-exchange cross-section, the situation changes dramatically. The strong dependence of the solar wind speed on the pickup proton temperature disappears and the transition region in the heliosheath disappears as well, at least at reasonable distances from the TS.

  6. A comb-sampling method for enhanced mass analysis in linear electrostatic ion traps

    Energy Technology Data Exchange (ETDEWEB)

    Greenwood, J. B.; Kelly, O.; Calvert, C. R.; Duffy, M. J.; King, R. B.; Belshaw, L.; Graham, L.; Alexander, J. D.; Williams, I. D. [Centre for Plasma Physics, School of Mathematics and Physics, Queen' s University Belfast, Belfast BT7 1NN (United Kingdom); Bryan, W. A. [Department of Physics, Swansea University, Swansea SA2 8PP (United Kingdom); Turcu, I. C. E.; Cacho, C. M.; Springate, E. [Central Laser Facility, STFC Rutherford Appleton Laboratory, Didcot, Oxfordshire OX11 0QX (United Kingdom)

    2011-04-15

    In this paper an algorithm for extracting spectral information from signals containing a series of narrow periodic impulses is presented. Such signals can typically be acquired by pickup detectors from the image-charge of ion bunches oscillating in a linear electrostatic ion trap, where frequency analysis provides a scheme for high-resolution mass spectrometry. To provide an improved technique for such frequency analysis, we introduce the CHIMERA algorithm (Comb-sampling for High-resolution IMpulse-train frequency ExtRAaction). This algorithm utilizes a comb function to generate frequency coefficients, rather than using sinusoids via a Fourier transform, since the comb provides a superior match to the data. This new technique is developed theoretically, applied to synthetic data, and then used to perform high resolution mass spectrometry on real data from an ion trap. If the ions are generated at a localized point in time and space, and the data is simultaneously acquired with multiple pickup rings, the method is shown to be a significant improvement on Fourier analysis. The mass spectra generated typically have an order of magnitude higher resolution compared with that obtained from fundamental Fourier frequencies, and are absent of large contributions from harmonic frequency components.

  7. MAVEN SupraThermal and Thermal Ion Compostion (STATIC) Instrument

    Science.gov (United States)

    McFadden, J. P.; Kortmann, O.; Curtis, D.; Dalton, G.; Johnson, G.; Abiad, R.; Sterling, R.; Hatch, K.; Berg, P.; Tiu, C.; Gordon, D.; Heavner, S.; Robinson, M.; Marckwordt, M.; Lin, R.; Jakosky, B.

    2015-12-01

    The MAVEN SupraThermal And Thermal Ion Compostion (STATIC) instrument is designed to measure the ion composition and distribution function of the cold Martian ionosphere, the heated suprathermal tail of this plasma in the upper ionosphere, and the pickup ions accelerated by solar wind electric fields. STATIC operates over an energy range of 0.1 eV up to 30 keV, with a base time resolution of 4 seconds. The instrument consists of a toroidal "top hat" electrostatic analyzer with a 360° × 90° field-of-view, combined with a time-of-flight (TOF) velocity analyzer with 22.5° resolution in the detection plane. The TOF combines a -15 kV acceleration voltage with ultra-thin carbon foils to resolve H+, He^{++}, He+, O+, O2+, and CO2+ ions. Secondary electrons from carbon foils are detected by microchannel plate detectors and binned into a variety of data products with varying energy, mass, angle, and time resolution. To prevent detector saturation when measuring cold ram ions at periapsis (˜10^{1 1} eV/cm2 s sr eV), while maintaining adequate sensitivity to resolve tenuous pickup ions at apoapsis (˜103 eV/cm2 s sr eV), the sensor includes both mechanical and electrostatic attenuators that increase the dynamic range by a factor of 103. This paper describes the instrument hardware, including several innovative improvements over previous TOF sensors, the ground calibrations of the sensor, the data products generated by the experiment, and some early measurements during cruise phase to Mars.

  8. Power, Space and Resistance: Foucauldian Reading of "The Pickup"

    Science.gov (United States)

    Babapi, Nasrin; Parvaneh, Farid

    2015-01-01

    The present article is an attempt to read Nadin Gordimer's "The Pickup" from the lens of Foucault. It starts with Foucault's assumption that power is everything and any kind of relation in the world is defined through the discourses of power. It discusses the techniques through which the power dominates its authority over the subjects…

  9. Medium-energy electrons and heavy ions in Jupiter's magnetosphere - Effects of lower hybrid wave-particle interactions

    Science.gov (United States)

    Barbosa, D. D.

    1986-01-01

    A theory of medium-energy (about keV) electrons and heavy ions in Jupiter's magnetosphere is presented. Lower hybrid waves are generated by the combined effects of a ring instability of neutral wind pickup ions and the modified two-stream instability associated with transport of cool Iogenic plasma. The quasi-linear energy diffusion coefficient for lower hybrid wave-particle interactions is evaluated, and several solutions to the diffusion equation are given. Calculations based on measured wave properties show that the noise substantially modifies the particle distribution functions. The effects are to accelerate superthermal ions and electrons to keV energies and to thermalize the pickup ions on time scales comparable to the particle residence time. The S(2+)/S(+) ratio at medium energies is a measure of the relative contribution from Iogenic thermal plasma and neutral wind ions, and this important quantity should be determined from future measurements. The theory also predicts a preferential acceleration of heavy ions with an accleration time that scales inversely with the root of the ion mass. Electrons accelerated by the process contribute to further reionization of the neutral wind by electron impact, thus providing a possible confirmation of Alfven's critical velocity effect in the Jovian magnetosphere.

  10. Position pickup of the PS Booster

    CERN Multimedia

    CERN PhotoLab

    1975-01-01

    The beam position around the 4 rings of the PS Booster (originally 800 MeV, now 1.4 GeV), is measured with electrostatic pickups (PU). They consist of a ceramic cylinder forming part of the vacuum chamber, and, in order to save space, they are located inside the multipole lenses. The inside of the ceramic is coated with a metallic layer, into which the form of the electrodes was cut by computer-controlled micro-sandblasting. Each PU has a pair of horizontal and a pair of vertical electrodes, as well as a separate intensity-sensing circular electrode.

  11. Direct and Recoil-Induced Electron Emission from Ion-Bombarded Solids

    DEFF Research Database (Denmark)

    Holmen, G.; Svensson, B.; Schou, Jørgen

    1979-01-01

    The kinetic emission of secondary electrons from ion-bombarded solid surfaces is split into two contributions, a direct one caused by ionizing collisions between the bombarding ion and target atoms, and an indirect one originating from ionizing collisions undergone by recoil atoms with other target...... atoms. The direct contribution, which has been treated by several authors in previous studies, shows a behavior that is determined primarily by the electronic stopping power of the bombarding ion, while the indirect contribution is nonproportionally related to the nuclear stopping power. This latter...

  12. Branch-and-Cut-and-Price for the Pickup and Delivery Problem with Time Windows

    DEFF Research Database (Denmark)

    Røpke, Stefan; Cordeau, Jean-Francois

    2009-01-01

    In the pickup and delivery problem with time windows (PDPTW), vehicle routes must be designed to satisfy a set of transportation requests, each involving a pickup and a delivery location, under capacity, time window, and precedence constraints. This paper introduces a new branch......-and-cut-and-price algorithm in which lower bounds are computed by solving through column generation the linear programming relaxation of a set partitioning formulation. Two pricing subproblems are considered in the column generation algorithm: an elementary and a non-elementary shortest path problem. Valid inequalities...

  13. Ac-loss measurement of coated conductors: The influence of the pick-up coil position

    International Nuclear Information System (INIS)

    Schmidt, Curt

    2008-01-01

    The ac-loss measurement by the magnetization method requires calibration for obtaining absolute values. A convenient way of calibration is the calorimetric measurement which yields, within the measuring accuracy, absolute loss values. In the magnetization measurement the hysteresis loop of sample magnetization which determines the losses is measured via the integration of magnetic flux penetrating a pick-up coil. The ratio of flux integral to magnetization integral and hence the calibration factor is however, for a given pick-up coil geometry, not exactly a constant, but depends on the magnetization current pattern within the sample. Especially for thin tapes in perpendicular external field this effect has to be taken into consideration in order to avoid miss measurements. The relation between measured flux and sample magnetization was calculated for special cases of magnetization current distribution in the sample as a function of the pick-up coil position. Furthermore calibration factors were measured as a function of the ac-field amplitude and the result compared with available theoretical models. A good agreement was found between experiment and theory

  14. GRASP with path-relinking for the selective pickup and delivery problem

    DEFF Research Database (Denmark)

    Ho, Sin C.; Szeto, W. Y.

    2016-01-01

    Bike sharing systems are very popular nowadays. One of the characteristics is that bikes are picked up from some surplus bike stations and transported to all deficit bike stations by a repositioning vehicle with limited capacity to satisfy the demand of deficit bike stations. Motivated by this real...... world bicycle repositioning problem, we study the selective pickup and delivery problem, where demand at every delivery node has to be satisfied by the supply collected from a subset of pickup nodes. The objective is to minimize the total travel cost incurred from visiting the nodes. We present a GRASP...... with path-relinking for solving the described problem. Experimental results show that this simple heuristic improves the existing results in the literature with an average improvement of 5.72% using small computing times. The proposed heuristic can contribute to the development of effective and efficient...

  15. Slot-type pickup/kicker for AA stochastic cooling

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    A "slotted transmission line" was used for both pickups and kickers of the cooling systems of the AA. They served for the cooling of the high-density antiproton stack, in momentum and both transverse planes. In the beginning in a single band, 1-2 GHz, later in 2 bands, 2-4 and 4-8 GHz. Here we see the slotted electrodes partly pulled out of the outer casing. See also 7906189, 7906581X, 7896193.

  16. (p, α) reactions: knock-on(out) or pick-up

    International Nuclear Information System (INIS)

    Gadioli, E.

    1983-01-01

    Nothwithstanding the great lot of data collected starting from the beginning of fifties, it cannot be said that a good degree of knowledge about the (p, α) reaction mechanism has been reached. Experimental data are usually interpreted or on the basis of a pure pick-up or knock-on(out) mechanism, though many results suggest the importance of both mechanism

  17. MAVEN Observations of Escaping Planetary Ions from the Martian Atmosphere: Mass, Velocity, and Spatial Distributions

    Science.gov (United States)

    Dong, Yaxue; Fang, Xiaohua; Brain, D. A.; McFadden, James P.; Halekas, Jasper; Connerney, Jack

    2015-04-01

    The Mars-solar wind interaction accelerates and transports planetary ions away from the Martian atmosphere through a number of processes, including ‘pick-up’ by electromagnetic fields. The MAVEN spacecraft has made routine observations of escaping planetary ions since its arrival at Mars in September 2014. The SupraThermal And Thermal Ion Composition (STATIC) instrument measures the ion energy, mass, and angular spectra. It has detected energetic planetary ions during most of the spacecraft orbits, which are attributed to the pick-up process. We found significant variations in the escaping ion mass and velocity distributions from the STATIC data, which can be explained by factors such as varying solar wind conditions, contributions of particles from different source locations and different phases during the pick-up process. We also study the spatial distributions of different planetary ion species, which can provide insight into the physics of ion escaping process and enhance our understanding of atmospheric erosion by the solar wind. Our results will be further interpreted within the context of the upstream solar wind conditions measured by the MAVEN Solar Wind Ion Analyzer (SWIA) instrument and the magnetic field environment measured by the Magnetometer (MAG) instrument. Our study shows that the ion spatial distribution in the Mars-Sun-Electric-Field (MSE) coordinate system and the velocity space distribution with respect to the local magnetic field line can be used to distinguish the ions escaping through the polar plume and those through the tail region. The contribution of the polar plume ion escape to the total escape rate will also be discussed.

  18. Beam emittance measurements on multicusp ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Sarstedt, M.; Lee, Y.; Leung, K.N. [and others

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 {mu}m patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma.

  19. Beam emittance measurements on multicusp ion sources

    International Nuclear Information System (INIS)

    Sarstedt, M.; Lee, Y.; Leung, K.N.

    1995-08-01

    Multicusp ion sources are used for various applications. Presently, the implementation of this type of ion source planned for the development of an ion beam lithography machine, which will be used for the projection of sub-0.2 μm patterns onto a wafer substrate. Since, for this application, a very good beam quality and a small ion energy spread are required, emittance measurements have been performed on a multicusp ion source for various source conditions. It is shown that the installation of proper capacitors between the extraction electrodes is necessary to avoid rf-pickup, which otherwise leads to a distortion of the beam emittance. The influence of the magnetic filter field on the beam emittance has been investigated, and the beam emittance of a dc filament-discharge plasma has also been compared to that of an rf-generated plasma

  20. The effect of minor alloying elements on oxidation and hydrogen pickup in Zr-2.5Nb

    International Nuclear Information System (INIS)

    Ploc, R.A.

    2002-01-01

    In CANDU reactors, fuel and coolant are contained in horizontal pressure tubes made of Zr-2.5 wt% Nb alloy. In the past decade, the effect of more than 20 impurity elements, in various concentrations, on oxidation and deuterium pickup (at 300 o C, pD = 10.5, Li 2 O) have been investigated in over 70 Zr-2.5Nb alloys. The studies were performed using non-consumable arc-melted alloy logs that were rolled and made into corrosion coupons and corroded in autoclaves. This study represents one of the largest collections of previously unpublished data on the effect of impurity elements on oxide film growth and deuterium pickup in a zirconium alloy. Elements such as Al, Ti, Mn, and Pt, to name but a few, were found to significantly accelerate the corrosion process. Some elements, such as tin, had a positive effect on oxidation (lowers the rate of oxide film development) and a negative effect on hydrogen pickup (increases pickup). Three parameters were important to the corrosion process, namely, microstructure, surface finish, and synergistic interactions between the impurity elements. The above studies culminated in two response surface analyses (RSA). The first was conducted on the effect of C and Fe on oxygen and deuterium pickup in Zr-2.5Nb drop castings corroded at 325 o C in CANDU conditions. The second study was performed in autoclaves at 300 o C on the affect of four impurity elements, C, Fe, Cr, and Si, in Zr-2.5Nb micro-tubes, which possess the same microstructure as full-size pressure tubes. The first RSA revealed a quadratic dependence of corrosion on C and Fe concentrations, with an optimum resistance at about 30 ppm (wt) C and 1100 ppm (wt) Fe. This has been partially confirmed by out-reactor corrosion of Zr-2.5Nb-Fe micro-pressure tubes. Trends in- and out-reactor were similar for oxidation but different in magnitude for deuterium pickup. There is no linear dependence on the Fe concentration in-reactor, implying that Fe and C form a complex. The second RSA

  1. The effect of minor alloying elements on oxidation and hydrogen pickup in Zr-2.5Nb

    International Nuclear Information System (INIS)

    Ploc, R.A.

    2002-01-01

    In CANDU reactors, fuel and coolant are contained in horizontal pressure tubes made of Zr-2.5 wt% Nb alloy. In the past decade, the effect of more than 20 impurity elements, in various concentrations, on oxidation and deuterium pickup (at 300 deg C, pD = 10.5, Li 2 O) have been investigated in over 70 Zr-2.5Nb alloys. The studies were performed using non-consumable arc-melted alloy logs that were rolled and made into corrosion coupons and corroded in autoclaves. This study represents one of the largest collections of previously unpublished data on the effect of impurity elements on oxide film growth and deuterium pickup in a zirconium alloy. Elements such as Al, Ti, Mn, and Pt, to name but a few, were found to significantly accelerate the corrosion process. Some elements, such as tin, had a positive effect on oxidation (lowers the rate of oxide film development) and a negative effect on hydrogen pickup (increases pickup). Three parameters were important to the corrosion process, namely, microstructure, surface finish, and synergistic interactions between the impurity elements. The above studies culminated in two response surface analyses (RSA). The first was conducted on the effect of C and Fe on oxygen and deuterium pickup in Zr-2.5Nb drop castings corroded at 325 deg C in CANDU conditions. The second study was performed in autoclaves at 300 deg C on the affect of four impurity elements, C, Fe, Cr, and Si, in Zr-2.5Nb micro-tubes, which possess the same microstructure as full-size pressure tubes. The first RSA revealed a quadratic dependence of corrosion on C and Fe concentrations, with an optimum resistance at about 30 ppm (wt) C and 1100 ppm (wt) Fe. This has been partially confirmed by out-reactor corrosion of Zr-2.5Nb-Fe micro-pressure tubes. Trends in- and out-reactor were similar for oxidation but different in magnitude for deuterium pickup. There is no linear dependence on the Fe concentration in-reactor, implying that Fe and C form a complex. The second

  2. Plasma flow measurement using directional Langmuir probe under weakly ion-magnetized conditions

    Energy Technology Data Exchange (ETDEWEB)

    Nagaoka, Kenichi; Okamoto, Atsushi [Graduate School of Science, Nagoya Univ., Nagoya (Japan); Yoshimura, Shinji; Tanaka, Masayoshi Y. [National Inst. for Fusion Science, Toki, Gifu (Japan)

    2000-07-01

    It is both experimentally and theoretically demonstrated that ion flow velocity at an arbitrary angle with respect to the magnetic field can be measured with a directional Langmuir probe. Based on the symmetry argument, we show that the effect of magnetic field on directional probe current is exactly canceled in determining the ion flow velocity, and obtain the generalized relation between flow velocity and directional probe currents valid for any flowing direction. The absolute value of the flow velocity is determined by an in situ calibration method of the probe. The applicability limit of the present method to a strongly ion-magnetized plasma is experimentally examined. (author)

  3. First-Year Wilkinson Microwave Anisotropy Probe (WMAP) Observations: Galactic Signal Contamination from Sidelobe Pickup

    Science.gov (United States)

    Barnes, C.; Hill, R. S.; Hinshaw, G.; Page, L.; Bennett, C. L.; Halpern, M.; Jarosik, N.; Kogut, A.; Limon, M.; Meyer, S. S.; Tucker, G. S.; Wollack, E.; Wright, E. L.

    2003-09-01

    Since the Galactic center is ~1000 times brighter than fluctuations in the cosmic microwave background (CMB), CMB experiments must carefully account for stray Galactic pickup. We present the level of contamination due to sidelobes for the first-year CMB maps produced by the Wilkinson Microwave Anisotropy Probe (WMAP) observatory. For each radiometer, full 4π sr antenna gain patterns are determined from a combination of numerical prediction and ground-based and space-based measurements. These patterns are convolved with the WMAP first-year sky maps and observatory scan pattern to generate the expected sidelobe signal contamination, for both intensity and polarized microwave sky maps. When the main beams are outside of the Galactic plane, we find rms values for the expected sidelobe pickup of 15, 2.1, 2.0, 0.3, and 0.5 μK for the K, Ka, Q, V, and W bands, respectively. Except for at the K band, the rms polarized contamination is the Galactic pickup are presented. WMAP is the result of a partnership between Princeton University and the NASA Goddard Space Flight Center. Scientific guidance is provided by the WMAP Science Team.

  4. The ATLAS beam pick-up based timing system

    International Nuclear Information System (INIS)

    Ohm, C.; Pauly, T.

    2010-01-01

    The ATLAS BPTX stations are composed of electrostatic button pick-up detectors, located 175 m away along the beam pipe on both sides of ATLAS. The pick-ups are installed as a part of the LHC beam instrumentation and used by ATLAS for timing purposes. The usage of the BPTX signals in ATLAS is twofold: they are used both in the trigger system and for LHC beam monitoring. The BPTX signals are discriminated with a constant-fraction discriminator to provide a Level-1 trigger when a bunch passes through ATLAS. Furthermore, the BPTX detectors are used by a stand-alone monitoring system for the LHC bunches and timing signals. The BPTX monitoring system measures the phase between collisions and clock with a precision better than 100 ps in order to guarantee a stable phase relationship for optimal signal sampling in the sub-detector front-end electronics. In addition to monitoring this phase, the properties of the individual bunches are measured and the structure of the beams is determined. On September 10, 2008, the first LHC beams reached the ATLAS experiment. During this period with beam, the ATLAS BPTX system was used extensively to time in the read-out of the sub-detectors. In this paper, we present the performance of the BPTX system and its measurements of the first LHC beams.

  5. Ion-beam-directed self-organization of conducting nanowire arrays

    International Nuclear Information System (INIS)

    Batzill, M.; Bardou, F.; Snowdon, K. J.

    2001-01-01

    Glancing-incidence ion-beam irradiation has been used both to ease kinetic constraints which otherwise restrict the establishment of long-range order and to impose external control on the orientation of nanowire arrays formed during stress-field-induced self-ordering of calcium atoms on a CaF 2 (111) surface. The arrays exhibit exceptional long-range order, with the long axis of the wires oriented along the azimuthal direction of ion-beam incidence. Transport measurements reveal a highly anisotropic electrical conductivity, whose maximum lies in the direction of the long axis of the 10.1-nm-period calcium wires

  6. Biomolecular ions in superfluid helium nanodroplets

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Florez, Ana Isabel

    2016-07-01

    droplets has been recorded. The experimental results show well resolved spectra, which are in good agreement with theoretical calculations. Moreover, the weakly interacting nature of helium droplets is confirmed by the excellent agreement obtained with the available gas-phase data. Using standard gas-phase mass spectrometry techniques allows to study the molecular ions as a function of charge state. As a result, the role of the interplay between Coulomb repulsion and hydrogen bonding in the secondary structure of the target molecules can be investigated. For this purpose, the infrared spectra of the proteins ubiquitin and cytochrome c embedded in helium droplets were recorded. The experimental results are interpreted in terms of a charge induced unzipping of the proteins, where a structural transition from helical into extended C{sub 5}-type hydrogen bonded structures occurs. This interpretation is supported by simple energy considerations, as well as by quantum chemical calculations on model peptides. The transition in secondary structure observed here is most likely universal for isolated proteins in the gas phase. Embedding positively charged ions inside helium droplets also offers the possibility to directly investigate the intrinsic properties of helium droplets. One fundamental characteristic of helium droplets is their unique ability to pick up the species with which they collide. In order to gain more insight into this process, the presence of an electrical charge was used to accelerate and detect the ion-doped droplets as a function of the mass and size of the dopant. A systematic investigation of the pick-up probability demonstrates the existence of a dopant dependent minimum droplet size below which no pick-up occurs. As a result, different hypotheses and theoretical models are proposed and discussed in order to shed more light into the constraints and limitations of the pick-up process.

  7. Biomolecular ions in superfluid helium nanodroplets

    International Nuclear Information System (INIS)

    Gonzalez Florez, Ana Isabel

    2016-01-01

    droplets has been recorded. The experimental results show well resolved spectra, which are in good agreement with theoretical calculations. Moreover, the weakly interacting nature of helium droplets is confirmed by the excellent agreement obtained with the available gas-phase data. Using standard gas-phase mass spectrometry techniques allows to study the molecular ions as a function of charge state. As a result, the role of the interplay between Coulomb repulsion and hydrogen bonding in the secondary structure of the target molecules can be investigated. For this purpose, the infrared spectra of the proteins ubiquitin and cytochrome c embedded in helium droplets were recorded. The experimental results are interpreted in terms of a charge induced unzipping of the proteins, where a structural transition from helical into extended C 5 -type hydrogen bonded structures occurs. This interpretation is supported by simple energy considerations, as well as by quantum chemical calculations on model peptides. The transition in secondary structure observed here is most likely universal for isolated proteins in the gas phase. Embedding positively charged ions inside helium droplets also offers the possibility to directly investigate the intrinsic properties of helium droplets. One fundamental characteristic of helium droplets is their unique ability to pick up the species with which they collide. In order to gain more insight into this process, the presence of an electrical charge was used to accelerate and detect the ion-doped droplets as a function of the mass and size of the dopant. A systematic investigation of the pick-up probability demonstrates the existence of a dopant dependent minimum droplet size below which no pick-up occurs. As a result, different hypotheses and theoretical models are proposed and discussed in order to shed more light into the constraints and limitations of the pick-up process.

  8. Flow direction variations of low energy ions as measured by the ion electron sensor (IES) flying on board of Rosetta

    Science.gov (United States)

    Szegö, Karoly; Nemeth, Zoltan; Foldy, Lajos; Burch, James L.; Goldstein, Raymond; Mandt, Kathleen; Mokashi, Prachet; Broiles, Tom

    2015-04-01

    The Ion Electron Sensor (IES) simultaneously measures ions and electrons with two separate electrostatic plasma analyzers in the energy range of 4 eV- 22 keV for ions. The field of view is 90ox360o, with angular resolution 5ox45o for ions, with a sector containing the solar wind being further segmented to 5o × 5o. IES has operated continuously since early 2014. In the ion data a low energy (energy ions. Here we analyze the arrival direction of this low energy component. The origin of these low energy ions is certainly the ionized component of the neutral gas emitted due to solar activity from comet 67P/Churiumov-Gerasimenko. The low energy component in general shows a 6h periodicity due to cometary rotation. The data show, however, that the arrival direction of the low energy ions is smeared both in azimuth and elevation, due possibly to the diverse mechanisms affecting these ions. One of these effects is the spacecraft potential (~-10V), which accelerates the ions towards the spacecraft omnidirectionally. To characterize the flow direction in azimuth-elevation, we have integrated over the lowest 8 energy channels using weighted energy: sum(counts * energy)/sum(counts); and considered only cases when the counts are above 30. When we apply higher cut for counts, the flow direction became more definite. For this analysis we use data files where the two neighbouring energy values and elevation values are collapsed; and the azimuthal resolution is 45o, that is the solar wind azimuthal segmentation is also collapsed. Here we use day 2014.09.11. as illustration. On that day a solar wind shock reached the spacecraft at about ~10 UT. After the shock transition the energy of the solar wind became higher, and after ~12 UT the flow direction of the solar wind fluctuated, sometimes by 35o. On this day Rosetta flew at about 29.3-29.6 km from the nucleus. In the azimuth-elevation plots summed over "weighted energy" (as defined above) we were able to identify two flow directions

  9. Testbeam Studies on Pick-Up in Sensors with Embedded Pitch Adapters

    CERN Document Server

    Rehnisch, Laura; The ATLAS collaboration

    2018-01-01

    Embedded pitch adapters are an alternative solution to external pitch adapters widely used to facilitate the wire-bonding step when connecting silicon strip sensors and readout electronics of different pitch. The pad-pitch adaption can be moved into the sensor fabrication step by implementing a second layer of metal tracks, connected by vias to the primary metal layer of sensor strips. Such a solution, however, might bear the risk of performance losses introduced by various phenomena. One of these effects, the undesired capacitive coupling between the silicon bulk and this second metal layer (pick-up) has been investigated in photon testbeam measurements. For a worst-case embedded pitch adapter design, expected to be maximally susceptible to pick-up, a qualitative analysis has visualized the effect as a function of the location on the second metal layer structure. It was further found that the unwanted effect decreases towards expected values for operating thresholds of the binary readout used. Suggestions fo...

  10. Direct deposition of gold on silicon with focused ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Nebiker, P.W.; Doebeli, M. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Muehle, R. [Eidgenoessische Technische Hochschule, Zurich (Switzerland)

    1997-09-01

    Irradiation with ions at very low energies (below 500 eV) no longer induces a removal of substrate material, but the ions are directly deposited on the surface. In this way, gold has been deposited on silicon with focused ion beam exposure and the properties of the film have been investigated with atomic force microscopy and Auger electron spectroscopy. (author) 3 figs., 1 ref.

  11. Review of high excitation energy structures in heavy ion collisions: target excitations and three body processes

    International Nuclear Information System (INIS)

    Frascaria, N.

    1987-09-01

    A review of experimental results on high excitation energy structures in heavy ion inelastic scattering is presented. The contribution to the spectra of the pick-up break-up mechanism is discussed in the light of the data obtained with light heavy ion projectiles. Recent results obtained with 40 Ar beams at various energies will show that target excitations contribute strongly to the measured cross section

  12. Isotopic and velocity distributions of {sub 83}Bi produced in charge-pickup reactions of {sup 208}{sub 82}PB at 1 A GeV

    Energy Technology Data Exchange (ETDEWEB)

    Kelic, A.; Schmidt, K.H.; Enqvist, T. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (DE)] [and others

    2004-07-01

    Isotopically resolved cross sections and velocity distributions have been measured in charge-pickup reactions of 1 A GeV {sup 208}Pb with proton, deuterium and titanium target. The total and partial charge-pickup cross sections in the reactions {sup 208}Pb + {sup 1}H and {sup 208}Pb + {sup 2}H are measured to be the same in the limits of the error bars. A weak increase in the total charge-pickup cross section is seen in the reaction of {sup 208}Pb with the titanium target. The measured velocity distributions show different contributions - quasi-elastic scattering and {delta}-resonance excitation - to the charge-pickup production. Data on total and partial charge-pickup cross sections from these three reactions are compared with other existing data and also with model calculations based on the coupling of different intra-nuclear cascade codes and an evaporation code. (orig.)

  13. 47 CFR 74.431 - Special rules applicable to remote pickup stations.

    Science.gov (United States)

    2010-10-01

    ... occur outside the studio back to studio or production center. The transmitted material shall be intended... system. (b) Remote pickup mobile or base stations may be used for communications related to production..., Hawaii, Puerto Rico, and the Virgin Islands may be used for any purpose related to the programming or...

  14. Direct energy recovery from helium ion beams by a beam direct converter with secondary electron suppressors

    International Nuclear Information System (INIS)

    Yoshikawa, K.; Yamamoto, Y.; Toku, H.; Kobayashi, A.; Okazaki, T.

    1989-01-01

    A 5-yr study of beam direct energy conversion was performed at the Kyoto University Institute of Atomic Energy to clarify the essential features of direct energy recovery from monoenergetic ion beams so that the performance characteristics of energy recovery can be predicted reasonably well by numerical calculations. The study used an improved version of an electrostatically electron-suppressed beam direct converter. Secondary electron suppressor grids were added, and a helium ion beam was used with typical parameters of 15.4 keV, 90 mA, and 100 ms. This paper presents a comparison of experimental results with numerical results by the two-dimensional Kyoto University Advanced Dart (KUAD) code, including evaluation of atomic processes

  15. Lubricant Film Breakdown and Material Pick-Up in Sheet Forming of Advanced High Strength Steels and Stainless Steels when Using Environmental Friendly Lubricants

    DEFF Research Database (Denmark)

    Ceron, Ermanno; Olsson, M.; Bay, Niels

    2014-01-01

    chemically with the tool and workpiece material forming thin films, which adhere strongly to the surfaces and reduce the tendency to metal-metal contact and material pick-up. Production tests of new, environmentally benign tribo-systems are, however, costly and laboratory tests are preferred as a preliminary...... the tribological performance, i.e. tendency to material pick-up and galling, of the evaluated tribo-systems. Moreover the SEM analysis shows that different workpiece materials result in different types of material pick-up....

  16. Preliminary Specifications for the PS Pick-ups Amplifier to be used in the Transverse Damping System

    CERN Document Server

    Belleman, J; CERN. Geneva. AB Department

    2003-01-01

    The pick-up amplification stage to be used for the CODD in the PS is presently under redesign. It appears that the constraints for the circuit are very similar to those of the transverse feedback project. The AB/BDI group and in particular its PI section has kindly agreed to fulfil the RF group constraints so as to obtain a common design with a common control interface. The reliability aspect is not treated here. Nevertheless radiation has been considered. At the locations foreseen for the pick-ups (SS 2, 94, 98), the annual dose measured on the vacuum chamber (ref: CERN-TIS-2002-06-TE) is about 1000 Gray per year. This value is to be compared to the 100 Gy considered as the critical dose for electronic circuits. The radiation problem has been solved for the CODD pick-ups using distance and shield (active circuits 2 meters below the floor composed of concrete slabs). The same lay out will be applied for the dampers with the drawback of the capacitive plates being loaded with a low impedance -5 meters long- ca...

  17. Normative values and the effects of age, gender, and handedness on the Moberg Pick-Up Test.

    Science.gov (United States)

    Amirjani, Nasim; Ashworth, Nigel L; Gordon, Tessa; Edwards, David C; Chan, K Ming

    2007-06-01

    The Moberg Pick-Up Test is a standardized test for assessing hand dexterity. Although reduction of sensation in the hand occurs with aging, the effect of age on a subject's performance of the Moberg Pick-Up Test has not been examined. The primary goal of this study was to examine the impact of aging and, secondarily, the impact of gender and handedness, on performance of the Moberg Pick-Up Test in 116 healthy subjects. The average time to complete each of the four subsets of the test was analyzed using the Kruskal-Wallis, Mann-Whitney U, and Wilcoxon signed-rank tests. The results show that hand dexterity of the subjects was significantly affected by age, with young subjects being the fastest and elderly subjects the slowest. Women accomplished the test faster than men, and task performance with the dominant hand was faster than with the non-dominant hand. Use of normative values established based on age and gender is a valuable objective tool to gauge hand function in patients with different neurologic disorders.

  18. Properties of Laser-Produced Highly Charged Heavy Ions for Direct Injection Scheme

    CERN Document Server

    Sakakibara, Kazuhiko; Hayashizaki, Noriyosu; Ito, Taku; Kashiwagi, Hirotsugu; Okamura, Masahiro

    2005-01-01

    To accelerate highly charged intense ion beam, we have developed the Direct Plasma Injection Scheme (DPIS) with laser ion source. In this scheme an ion beam from a laser ion source is injected directly to a RFQ linac without a low energy beam transport (LEBT) and the beam loss in the LEBT can be avoided. We achieved high current acceleration of carbon ions (60mA) by DPIS with the high current optimized RFQ. As the next setp we will use heavier elements like Ag, Pb, Al and Cu as target in LIS (using CO2, Nd-YAG or other laser) for DPIS and will examine properties of laser-produced plasma (the relationship of between charge state and laser power density, the current dependence of the distance from the target, etc).

  19. Inelastic heavy ion scattering on 90Zr and 208Pb at intermediate energies

    International Nuclear Information System (INIS)

    Blumenfeld, Y.; Beaumel, D.; Chomaz, P.; Frascaria, N.; Garron, J.P.; Jacmart, J.C.; Roynette, J.C.; Scarpaci, J.A.; Suomijarvi, T.

    1988-01-01

    Heavy ion inelastic scattering has been investigated using the SPEG spectrometer at GANIL. It is shown that the use of such a high resolution spectrometer allows a quantitative study of the giant resonances excited in heavy ion collisions. The contribution of the pick-up break-up mechanism to the high excitation energy region (E > 30 MeV) is then discussed. Recent results obtained with 40 Ar beams at two different incident energies show that target excitations are also present in this energy region

  20. Pickup design for high bandwidth bunch arrival-time monitors in free-electron lasers

    Energy Technology Data Exchange (ETDEWEB)

    Angelovski, Aleksandar; Penirschke, Andreas; Jakoby, Rolf [TU Darmstadt (Germany). Institut fuer Mikrowellentechnik und Photonik; Kuhl, Alexander; Schnepp, Sascha [TU Darmstadt (Germany). Graduate School of Computational Engineering; Bock, Marie Kristin; Bousonville, Michael; Schlarb, Holger [Deutsches Elektronen-Synchrotron DESY, Hamburg (Germany); Weiland, Thomas [TU Darmstadt (Germany). Institut fuer Theorie Elektromagnetischer Felder

    2012-07-01

    The increased demands for low bunch charge operation mode in the free-electron lasers (FELs) require an upgrade of the existing synchronization equipment. As a part of the laser-based synchronization system, the bunch arrival-time monitors (BAMs) should have a sub-10 femtosecond precision for high and low bunch charge operation. In order to fulfill the resolution demands for both modes of operation, the bandwidth of such a BAM should be increased up to a cutoff frequency of 40 GHz. In this talk, we present the design and the realization of high bandwidth cone-shaped pickup electrodes as a part of the BAM for the FEL in Hamburg (FLASH) and the European X-ray free-electron laser (European XFEL). The proposed pickup was simulated with CST STUDIO SUITE, and a non-hermetic model was built up for radio frequency (rf) measurements.

  1. Laparoscopic ovum pick-up in spotted paca ( Cuniculus pacas )

    OpenAIRE

    Barros,F.F.P.C.; Teixeira,P.P.M.; Uscategui,R.A.R.; Coutinho,L.N.; Brito,M.B.S.; Kawanami,A.E.; Almeida,V.T.; Mariano,R.S.G.; Nociti,R.P.; Machado,M.R.F.; Vicente,W.R.R.

    2016-01-01

    ABSTRACT The aim of this work is study the laparoscopic ovum pick-up (LapOPU) technique in spotted paca, describing surgery details, complications and oocyte recovery rate. Nine healthy adult non-pregnant captive females were used, in a total of 39 procedures. When the surgical plane of anaesthesia was achieved, the females were positioned at 20º Trendelenburg. Three 6mm trocars were placed on right and left inguinal and hypogastric regions. Abdomen was inflated with CO2 and the intra-abdomin...

  2. High-performance integrated pick-up circuit for SPAD arrays in time-correlated single photon counting

    Science.gov (United States)

    Acconcia, Giulia; Cominelli, Alessandro; Peronio, Pietro; Rech, Ivan; Ghioni, Massimo

    2017-05-01

    The analysis of optical signals by means of Single Photon Avalanche Diodes (SPADs) has been subject to a widespread interest in recent years. The development of multichannel high-performance Time Correlated Single Photon Counting (TCSPC) acquisition systems has undergone a fast trend. Concerning the detector performance, best in class results have been obtained resorting to custom technologies leading also to a strong dependence of the detector timing jitter from the threshold used to determine the onset of the photogenerated current flow. In this scenario, the avalanche current pick-up circuit plays a key role in determining the timing performance of the TCSPC acquisition system, especially with a large array of SPAD detectors because of electrical crosstalk issues. We developed a new current pick-up circuit based on a transimpedance amplifier structure able to extract the timing information from a 50-μm-diameter custom technology SPAD with a state-of-art timing jitter as low as 32ps and suitable to be exploited with SPAD arrays. In this paper we discuss the key features of this structure and we present a new version of the pick-up circuit that also provides quenching capabilities in order to minimize the number of interconnections required, an aspect that becomes more and more crucial in densely integrated systems.

  3. A gas ionisation Direct-STIM detector for MeV ion microscopy

    International Nuclear Information System (INIS)

    Norarat, Rattanaporn; Guibert, Edouard; Jeanneret, Patrick; Dellea, Mario; Jenni, Josef; Roux, Adrien; Stoppini, Luc; Whitlow, Harry J.

    2015-01-01

    Direct-Scanning Transmission Ion Microscopy (Direct-STIM) is a powerful technique that yields structural information in sub-cellular whole cell imaging. Usually, a Si p-i-n diode is used in Direct-STIM measurements as a detector. In order to overcome the detrimental effects of radiation damage which appears as a broadening in the energy resolution, we have developed a gas ionisation detector for use with a focused ion beam. The design is based on the ETH Frisch grid-less off-axis Geiger–Müller geometry. It is developed for use in a MeV ion microscope with a standard Oxford Microbeams triplet lens and scanning system. The design has a large available solid angle for other detectors (e.g. proton induced fluorescence). Here we report the performance for imaging ReNcells VM with μm resolution where energy resolutions of <24 keV fwhm could be achieved for 1 MeV protons using isobutane gas

  4. Hi-Vision telecine system using pickup tube

    Science.gov (United States)

    Iijima, Goro

    1992-08-01

    Hi-Vision broadcasting, offering far more lifelike pictures than those produced by existing television broadcasting systems, has enormous potential in both industrial and commercial fields. The dissemination of the Hi-Vision system will enable vivid, movie theater quality pictures to be readily enjoyed in homes in the near future. To convert motion film pictures into Hi-Vision signals, a telecine system is needed. The Hi-Vision telecine systems currently under development are the "laser telecine," "flying-spot telecine," and "Saticon telecine" systems. This paper provides an overview of the pickup tube type Hi-Vision telecine system (referred to herein as the Saticon telecine system) developed and marketed by Ikegami Tsushinki Co., Ltd.

  5. Relationship between wave energy and free energy from pickup ions in the Comet Halley environment

    Science.gov (United States)

    Huddleston, D. E.; Johnstone, A. D.

    1992-01-01

    The free energy available from the implanted heavy ion population at Comet Halley is calculated by assuming that the initial unstable velocity space ring distribution of the ions evolves toward a bispherical shell. Ultimately this free energy adds to the turbulence in the solar wind. Upstream and downstream free energies are obtained separately for the conditions observed along the Giotto spacecraft trajectory. The results indicate that the waves are mostly upstream propagating in the solar wind frame. The total free energy density always exceeds the measured wave energy density because, as expected in the nonlinear process of ion scattering, the available energy is not all immediately released. An estimate of the amount which has been released can be obtained from the measured oxygen ion distributions and again it exceeds that observed. The theoretical analysis is extended to calculate the k spectrum of the cometary-ion-generated turbulence.

  6. A Substantial Plume of Escaping Planetary Ions in the MSE Northern Hemisphere Observed by MAVEN

    Science.gov (United States)

    Dong, Y.; Fang, X.; Brain, D. A.; McFadden, J. P.; Halekas, J. S.; Connerney, J. E. P.; Curry, S.; Harada, Y.; Luhmann, J. G.; Jakosky, B. M.

    2015-12-01

    The Mars-solar wind interaction accelerates and transports planetary ions away from Mars through a number of processes, including pick-up by the electromagnetic fields. The Mars Atmospheric and Volatile EvolutioN (MAVEN) spacecraft has frequently detected strong escaping planetary ion fluxes in both tailward and upstream solar wind motional electric field directions since the beginning of its science phase in November 2014. Our statistical study using three-month MAVEN data from November 2014 through February 2015 illustrates a substantial plume-like escaping planetary ion population organized by the upstream electric field with strong fluxes widely distributed in the northern hemisphere of the Mars-Sun-Electric-field (MSE) coordinate system, which is generally consistent with model predictions. The plume constitutes an important planetary ion escape channel from the Martian atmosphere in addition to the tailward escape. The >25eV O+ escape rate through the plume is estimated to be ~35% of the tailward escape and ~25% of the total escape. We will compare the dynamics of the plume and tailward escaping ions based on their velocity-space distributions with respect to the electromagnetic fields. We will also discuss the variations of the plume characteristics between different ion species (O+, O2+, and CO2+) and from the effect of different solar wind and interplanetary magnetic field (IMF) conditions.

  7. Methane Group Ions in Saturn’s Outer Magnetosphere?

    Science.gov (United States)

    Sittler, E. C.; Hartle, R. E.; Cooper, J. F.; Johnson, R. E.; Smith, H.; Shappirio, M.; Reisenfeld, D. B.

    2009-12-01

    Yelle et al. [2008] have estimated from Cassini Ion Neutral Mass Spectrometer (INMS) measurements that methane is escaping from Titan’s upper atmosphere at the rate of 2.5-3.0×109 mol/cm2/s and in order to explain this loss rate Strobel [2008] has proposed a hydrodynamic escape model to explain such high loss rates. This translates to loss of 2.8×1027 methane mol/s. The consequence of this work is the formation of a methane torus around Saturn which will dissociate to CH3 and other fragments of methane. The CH3 will then become ionized to form CH3+ with pickup energies ≈ keV after which it can be detected by the Cassini Plasma Spectrometer (CAPS) Ion Mass Spectrometer (IMS). Up till now the ion composition within Saturn’s outer magnetosphere in the vicinity of Titan’s orbit have yielded negative results with water group ions W+ dominating. The water group ions probably result from the emission of fast neutrals from the Enceladus torus via charge exchange reactions but still gravitationally bound to Saturn [see Johnson et al., 2005 and Sittler et al. 2006] and then become ionized in the outer magnetosphere as ~≈keV pickup ions. The CAPS IMS produces two ion composition data products, one called Straight Through (ST) and the other Linear Electric Field (LEF). The first has a higher sensitivity, while the latter has a greater discrimination in time-of-flight (TOF). For ST data O+ and CH4+ have similar TOF with the primary discriminator being the O- fragment which appears at a different TOF than for mass 16 ions. One can also look for other discriminators called ghost peaks. In case of LEF W+ ions produce TOF peak close to that for atomic O+ and the methane will produce TOF close to that for atomic C+ which has a significantly different(shorter) TOF than O+. We will be reporting on our continual search for methane ions within Saturn’s outer magnetosphere. References: 1. Yelle, R. V., J. Cui and I.C.F. Müller-Wodarg, JGR, 2008. 2. Strobel, D. F., Icarus

  8. Development of 80- and 100- Mile Work Day Cycles Representative of Commercial Pickup and Delivery Operation

    Energy Technology Data Exchange (ETDEWEB)

    Duran, Adam W [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kelly, Kenneth J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kresse, John [Cummins; Li, Ke [Cummins

    2018-04-03

    When developing and designing new technology for integrated vehicle systems deployment, standard cycles have long existed for chassis dynamometer testing and tuning of the powertrain. However, to this day with recent developments and advancements in plug-in hybrid and battery electric vehicle technology, no true 'work day' cycles exist with which to tune and measure energy storage control and thermal management systems. To address these issues and in support of development of a range-extended pickup and delivery Class 6 commercial vehicle, researchers at the National Renewable Energy Laboratory in collaboration with Cummins analyzed 78,000 days of operational data captured from more than 260 vehicles operating across the United States to characterize the typical daily performance requirements associated with Class 6 commercial pickup and delivery operation. In total, over 2.5 million miles of real-world vehicle operation were condensed into a pair of duty cycles, an 80-mile cycle and a 100-mile cycle representative of the daily operation of U.S. class 3-6 commercial pickup and delivery trucks. Using novel machine learning clustering methods combined with mileage-based weighting, these composite representative cycles correspond to 90th and 95th percentiles for daily vehicle miles traveled by the vehicles observed. In addition to including vehicle speed vs time drive cycles, in an effort to better represent the environmental factors encountered by pickup and delivery vehicles operating across the United States, a nationally representative grade profile and key status information were also appended to the speed vs. time profiles to produce a 'work day' cycle that captures the effects of vehicle dynamics, geography, and driver behavior which can be used for future design, development, and validation of technology.

  9. The Multi-commodity One-to-one Pickup-and-delivery Traveling Salesman Problem with Path Duration Limits

    DEFF Research Database (Denmark)

    Plum, Christian Edinger Munk; Pisinger, David; Salazar-González, Juan-José

    2012-01-01

    The design of container shipping networks is an important real world problem, with assets and operational costs in billions of dollars. To guide the optimal deployment of the ships, a single vessel roundtrip is considered by minimizing operational costs and flowing the best paying cargo under...... commercial constraints. Inspiration for formulation and solution method is taken from the rich research done within pickup and delivery problems. The problem, the multicommodity one-toone pickup and delivery traveling salesman problem with path duration limits is, to the best of out knowledge, considered...... for the first time. An arc flow and a path flow model are presented. A Branch and Cut and Price solution method is proposed and implemented....

  10. Comparison of magnetic and electrostatic Schottky pick-up in the CERN AD

    CERN Document Server

    Federmann, S

    2013-01-01

    The present note is intended to exploit the possibility of using a dedicated electrostatic beam pick-up for Schottky diagnostics in the future ELENA ring. A test setup is described allowing the evaluation of its performance compared to the extra low-noise beam current transformer used successfully in the AD. The results of this experiment are summarized and discussed.

  11. Magnetic Reconnection Processes Involving Modes Propagating in the Ion Diamagnetic Velocity Direction

    Science.gov (United States)

    Buratti, P.; Coppi, B.; Pucella, G.; Zhou, T.

    2013-10-01

    Experiments in weakly collisional plasma regimes, (e.g. neutral beam heated plasmas in the H-regime), measuring the Doppler shift associated with the plasma local rotation, have shown that the toroidal mode phase velocity vph in the frame with Er = 0 is in the direction of the ion diamagnetic velocity. For ohmically heated plasmas, with higher collisionalities, vph in the laboratory frame is in the direction of the electron diamagnetic velocity, but plasma rotation is reversed as well, and vph, in the Er = 0 frame, is in the ion diamagnetic velocity direction. Theoretically, two classes of reconnecting modes should emerge: drift-tearing modes and ``inductive modes'' that depend on the effects of a finite plasma inductivity. The former modes, with vph in the direction of the electron diamagnetic velocity, require the pre-excitation of a different kind of mode in order to become unstable in weakly collisional regimes. The second kind of modes has a growth rate associated with the relevant finite ion viscosity. A comprehensive theory is presented. Sponsored in part by the US DOE.

  12. A spin-filter polarimeter for low energy hydrogen and deuterium ion beams

    International Nuclear Information System (INIS)

    Lemieux, S.K.; Clegg, T.B.; Karwowski, H.J.; Thompson, W.J.; Crosson, E.R.

    1993-01-01

    An efficient polarimeter which reveals populations of individual hyperfine states of nuclear-spin-polarized H ± (or D ± ) ion beams has been tested. This device is based on unique properties of a three-level interaction in the 2S 1/2 and 2P 1/2 states of hydrogen (or deuterium) atoms, created when the incident, polarized ion beams undergo electron pickup in cesium vapour. Used on a polarized ion source, its efficiency faciy facilitates both rapid optimization and continual monitoring of parameters that affect the beam polarization. With such sources, and perhaps in applications with polarized gas jet targets, the device has potential for an absolute accuracy of better than 2%. (orig.)

  13. Exceptional ion rejection ability of directional solvent for non-membrane desalination

    Energy Technology Data Exchange (ETDEWEB)

    Rish, Daniel [Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, Indiana 46556 (United States); Department of Civil Engineering, University of Notre Dame, Notre Dame, Indiana 46556 (United States); Luo, Shirui; Kurtz, Brien [Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, Indiana 46556 (United States); Luo, Tengfei, E-mail: tluo@nd.edu [Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, Indiana 46556 (United States); Center for Sustainable Energy at Notre Dame, University of Notre Dame, Notre Dame, Indiana 46556 (United States)

    2014-01-13

    The recently demonstrated directional solvent extraction (DSE) is promising for very low temperature, membrane-free water desalination. In this paper, we combine atomistic simulations and experimental validation to demonstrate that the currently used directional solvent, decanoic acid, can reject all major salt ions in seawater, with very high rejection rates. The salinities of the DSE recovered water show that ion rejection rates are ∼98%–99%—similar to those of the best reverse osmosis membranes. Our test also shows that the DSE process can desalt seawater to produce fresh water that meets drinking water standards.

  14. Exceptional ion rejection ability of directional solvent for non-membrane desalination

    International Nuclear Information System (INIS)

    Rish, Daniel; Luo, Shirui; Kurtz, Brien; Luo, Tengfei

    2014-01-01

    The recently demonstrated directional solvent extraction (DSE) is promising for very low temperature, membrane-free water desalination. In this paper, we combine atomistic simulations and experimental validation to demonstrate that the currently used directional solvent, decanoic acid, can reject all major salt ions in seawater, with very high rejection rates. The salinities of the DSE recovered water show that ion rejection rates are ∼98%–99%—similar to those of the best reverse osmosis membranes. Our test also shows that the DSE process can desalt seawater to produce fresh water that meets drinking water standards

  15. The Influence of Pickup Protons, from Interstellar Neutral Hydrogen, on the Propagation of Interplanetary Shocks from the Halloween 2003 Solar Events to ACE and Ulysses: A 3-D MHD Modeling Study

    Science.gov (United States)

    Detman, T. R.; Intriligator, D. S.; Dryer, M.; Sun, W.; Deehr, C. S.; Intriligator, J.

    2012-01-01

    We describe our 3-D, time ]dependent, MHD solar wind model that we recently modified to include the physics of pickup protons from interstellar neutral hydrogen. The model has a time-dependent lower boundary condition, at 0.1 AU, that is driven by source surface map files through an empirical interface module. We describe the empirical interface and its parameter tuning to maximize model agreement with background (quiet) solar wind observations at ACE. We then give results of a simulation study of the famous Halloween 2003 series of solar events. We began with shock inputs from the Fearless Forecast real ]time shock arrival prediction study, and then we iteratively adjusted input shock speeds to obtain agreement between observed and simulated shock arrival times at ACE. We then extended the model grid to 5.5 AU and compared those simulation results with Ulysses observations at 5.2 AU. Next we undertook the more difficult tuning of shock speeds and locations to get matching shock arrival times at both ACE and Ulysses. Then we ran this last case again with neutral hydrogen density set to zero, to identify the effect of pickup ions. We show that the speed of interplanetary shocks propagating from the Sun to Ulysses is reduced by the effects of pickup protons. We plan to make further improvements to the model as we continue our benchmarking process to 10 AU, comparing our results with Cassini observations, and eventually on to 100 AU, comparing our results with Voyager 1 and 2 observations.

  16. Experimental cross sections for the pickup of electrons by relativistic nuclei

    International Nuclear Information System (INIS)

    Raisbeck, G.M.; Crawford, H.J.; Lindstroem, P.J.; Greiner, D.E.; Beiser, F.S.; Heckman, H.H.

    1977-01-01

    Cross sections for the pickup of electrons in a variety of targets have been measured with beams of 12 C (150, 250, 400 MeV/n), 20 Ne (250, 400, 1050, 2100 MeV/n) and 40 Ar (400, 1050 MeV/n) from the Bevalac accelerator. The interpretation of the results in terms of radiative and non-radiative capture, and the implications for cosmic ray propagation studies are discussed. (author)

  17. High-resolution ion pulse ionization chamber with air filling for the {sup 222}Rn decays detection

    Energy Technology Data Exchange (ETDEWEB)

    Gavrilyuk, Yu.M.; Gangapshev, A.M.; Gezhaev, A.M.; Etezov, R.A.; Kazalov, V.V.; Kuzminov, V.V. [Baksan Neutrino Observatory,Institute for Nuclear Research RAS, 361609 Neutrino (Russian Federation); Panasenko, S.I. [V.N.Karazin Kharkiv National University, 61022 Kharkiv (Ukraine); Ratkevich, S.S., E-mail: ssratk@gmail.com [V.N.Karazin Kharkiv National University, 61022 Kharkiv (Ukraine); Tekueva, D.A.; Yakimenko, S.P. [Baksan Neutrino Observatory,Institute for Nuclear Research RAS, 361609 Neutrino (Russian Federation)

    2015-11-21

    The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register α-particles from the {sup 222}Rn and its daughter's decays in the filled air sample. The detector is less sensitive to electromagnetic pick-ups and mechanical noises. The digital pulse processing method is proposed to improve the energy resolution of the ion pulse ionization chamber. An energy resolution of 1.6% has been achieved for the 5.49 MeV α-line. The dependence of the energy resolution on high voltage and working media pressure has been investigated and the results are presented. - Highlights: • The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. • The chamber is intended to register alpha-particles from {sup 222}Rn and its daughter's decays in the filled air sample. • The detector is less sensitive to electromagnetic pick-ups and mechanical noises. • An energy resolution of 1.6% has been achieved for the 5.49 MeV alpha-line. The dependence of the energy resolution on high voltage and working media pressure have been investigated and the results are presented.

  18. Transfer reactions with very heavy ions. Quarterly report 3. quarter 1987

    International Nuclear Information System (INIS)

    Juutinen, Sakari.

    1988-03-01

    This thesis deals with the reaction mechanism of the few-nucleon transfer reactions between the 58 Ni projectiles and the Dy targets. A series of transfer experiments utilizing the particle-γ coincidence technique was performed. Particle detection was used to give the scattering angles of two reaction products and the reaction channel was selected by the discrete γ-rays in the Ge detectors. Total γ-ray energy and multiplicity distributions were measured by the Spin Spectrometer. Total γ-ray energy and multiplicity distributions, γ-ray spectra obtained by the Ge and NaI detectors and angular distributions of the projectile-like ions are discussed. For one- and two-neutron transfer the experimental results provide direct evidence of a cold mechanism populating high-spin states near the yrast line. A schematic model for the transfer mechanism is proposed. This model accounts for the prominent features of one- and two-neutron pickup

  19. The Role of Pickup Ion Dynamics Outside of the Heliopause in the Limit of Weak Pitch Angle Scattering: Implications for the Source of the IBEX Ribbon

    Science.gov (United States)

    Zirnstein, E. J.; Heerikhuisen, J.; Dayeh, M. A.

    2018-03-01

    We present a new model of the Interstellar Boundary Explorer (IBEX) ribbon based on the secondary energetic neutral atom (ENA) mechanism, under the assumption that there is negligible pitch angle scattering of pickup ions (PUIs) outside the heliopause. Using the results of an MHD-plasma/kinetic-neutral simulation of the heliosphere, we generate PUIs in the outer heliosheath, solve their transport using guiding center theory, and compute ribbon ENA fluxes at 1 au. We implement several aspects of the PUI dynamics, including (1) parallel motion along the local interstellar magnetic field (ISMF), (2) advective transport with the interstellar plasma, (3) the mirror force acting on PUIs propagating along the ISMF, and (4) betatron acceleration of PUIs as they are advected within an increasing magnetic field toward the heliopause. We find that ENA fluxes at 1 au are reduced when PUIs are allowed to move along the ISMF, and ENA fluxes are reduced even more by the inclusion of the mirror force, which pushes particles away from IBEX lines of sight. Inclusion of advection and betatron acceleration do not result in any significant change in the ribbon. Interestingly, the mirror force reduces the ENA fluxes from the inner edge of the ribbon more than those from its outer edge, effectively reducing the ribbon’s width by ∼6° and increasing its radius projected on the sky. This is caused by the asymmetric draping of the ISMF around the heliopause, such that ENAs from the ribbon’s inner edge originate closer to the heliopause, where the mirror force is strongest.

  20. What Skills and Tactics Are Needed to Play Adult Pick-Up Basketball Games?

    Science.gov (United States)

    Wang, Jianyu; Liu, Wenhao; Moffit, Jeffrey

    2010-01-01

    The purpose of this study was to examine skill levels and performance patterns of regular players of pick-up basketball games. By a survey, 65 participants were identified as regular players and participated in the study. An observational instrument used to analyze game performance of the participants was developed and both content and construct…

  1. Direct photon production in heavy-ion reactions at SPS and RHIC

    Indian Academy of Sciences (India)

    They are considerably below the heavy-ion results which indicates that a simple scaling of prompt photons as observed in pp is not sufficient to explain the direct photons in central. Pb+Pb reactions. It is also instructive to compare the γ/π0 ratio extracted from heavy-ion data to those from pp and pC in figure 3. The value in ...

  2. A Combination of Meta-heuristic and Heuristic Algorithms for the VRP, OVRP and VRP with Simultaneous Pickup and Delivery

    Directory of Open Access Journals (Sweden)

    Maryam Ashouri

    2017-07-01

    Full Text Available Vehicle routing problem (VRP is a Nondeterministic Polynomial Hard combinatorial optimization problem to serve the consumers from central depots and returned back to the originated depots with given vehicles. Furthermore, two of the most important extensions of the VRPs are the open vehicle routing problem (OVRP and VRP with simultaneous pickup and delivery (VRPSPD. In OVRP, the vehicles have not return to the depot after last visit and in VRPSPD, customers require simultaneous delivery and pick-up service. The aim of this paper is to present a combined effective ant colony optimization (CEACO which includes sweep and several local search algorithms which is different with common ant colony optimization (ACO. An extensive numerical experiment is performed on benchmark problem instances addressed in the literature. The computational result shows that suggested CEACO approach not only presented a very satisfying scalability, but also was competitive with other meta-heuristic algorithms in the literature for solving VRP, OVRP and VRPSPD problems. Keywords: Meta-heuristic algorithms, Vehicle Routing Problem, Open Vehicle Routing Problem, Simultaneously Pickup and Delivery, Ant Colony Optimization.

  3. HTS planar gradiometer consisting of SQUID with multi-turn input coil and large pickup coil made of GdBCO coated conductor

    International Nuclear Information System (INIS)

    Tsukamoto, Akira; Adachi, Seiji; Oshikubo, Yasuo; Hato, Tsunehiro; Enpuku, Keiji; Sugisaki, Masaki; Arai, Eiichi; Tanabe, Keiichi

    2013-01-01

    Highlights: ► We fabricated a large HTS gradiometer with 350-mm-long baseline. ► A 6-turn gradiometric planar pickup was made of a HTS coated conductor. ► A 26-turn HTS input coil chip was stacked on a HTS thin film gradiometer chip. ► A mechanical balancing structure was also implemented. ► The fabricated gradiometer showed a gradient field noise of 0.8 fT/cm Hz 1/2 . -- Abstract: We have investigated the fabrication of a high-temperature superconducting (HTS) gradiometer with long baseline for geophysical applications. The proof-of-concept gradiometer using a 1-turn pickup coil made of a GdBa 2 Cu 3 O y coated conductor (GCC) and 5.5-turn input coil integrated on a SQUID was fabricated in our previous work. In this study, we have optimized the device structure to improve the frequency response, gradient field sensitivity and gradiometer balance. The fabricated flux transformer consists of a 6-turn planar gradiometric pickup coil and a 26-turn input coil made of an HTS thin film. A low-melting-point alloy was used to connect polished Ag surfaces of the CGG pickup coil and Au pads of the input coil. An HTS SQUID was formed on another substrate and stacked on the input coil. A mechanical balancing structure using three pieces of GCC as a superconducting shield was also implemented. The fabricated gradiometer showed a gradient field noise of 0.8 fT/cm Hz 1/2 in the white noise regions, a gradiometer balance of 1/142, and a cutoff frequency of 9 Hz corresponding to a 2 mΩ contact resistance between the pickup coil and the input coil

  4. Parallel electric fields accelerating ions and electrons in the same direction

    International Nuclear Information System (INIS)

    Hultqvist, B; Lundin, R.

    1988-01-01

    In this contribution the authors present Viking observations of electrons and positive ions which move upward along the magnetic field lines with energies of the same order of magnitude. The authors propose that both ions and electrons are accelerated by an electric field which has low-frequency temporal variations such that the ions experience and average electrostatic potential drop along the magnetic field lines whereas the upward streaming electrons are accelerated in periods of downward pointing electric field which is quasi-static for the electrons and forces them to beam out of the field region before the field changes direction

  5. Exact Solutions to the Symmetric and Asymmetric Vehicle Routing Problem with Simultaneous Delivery and Pick-Up

    Directory of Open Access Journals (Sweden)

    Julia Rieck

    2013-05-01

    Full Text Available In reverse logistics networks, products (e.g., bottles or containers have to be transported from a depot to customer locations and, after use, from customer locations back to the depot. In order to operate economically beneficial, companies prefer a simultaneous delivery and pick-up service. The resulting Vehicle Routing Problem with Simultaneous Delivery and Pick-up (VRPSDP is an operational problem, which has to be solved daily by many companies. We present two mixed-integer linear model formulations for the VRPSDP, namely a vehicle-flow and a commodity-flow model. In order to strengthen the models, domain-reducing preprocessing techniques, and effective cutting planes are outlined. Symmetric benchmark instances known from the literature as well as new asymmetric instances derived from real-world problems are solved to optimality using CPLEX 12.1.

  6. New formulation and branch-and-cut algorithm for the pickup and delivery traveling salesman problem with multiple stacks: new formulation and branch-and-cut algorithm

    NARCIS (Netherlands)

    Sampaio Oliveira, A.H.; Urrutia, S.

    2017-01-01

    In this paper, we consider the pickup and delivery traveling salesman problem with multiple stacks in which a single vehicle must serve a set of customer requests defined by a pair of pickup and delivery destinations of an item. The vehicle contains a fixed number of stacks, where each item is

  7. Beam position pickup for antiprotons to the ISR

    CERN Multimedia

    CERN PhotoLab

    1981-01-01

    The Antiproton Project, launched for proton-antiproton collisions in the SPS (SPS collider), had a side-line for p-pbar collisions in the ISR. A new transfer line, TT6, was constructed to transport antiprotons from the 26 GeV PS to the injection line TT1 of ISR ring 2. Antiprotons were a scarce commodity. For setting up the lines, beam diagnostic devices in the antiproton path had to work reliably and precisely with just a few low-intensity pilot pules: single bunches of about 2x10**9 antiprotons every few hours. Electrostatic pickup electrodes were used to measure beam position. They could be mounted for measurement in the horizontal plane, as in this picture, or at 90 deg, for the vertical plane.

  8. Electron Cloud Buildup Characterization Using Shielded Pickup Measurements and Custom Modeling Code at CESRTA

    CERN Document Server

    Crittenden, James A

    2013-01-01

    The Cornell Electron Storage Ring Test Accelerator experimental program includes investigations into electron cloud buildup, applying various mitigation techniques in custom vacuum chambers. Among these are two 1.1-m-long sections located symmetrically in the east and west arc regions. These chambers are equipped with pickup detectors shielded against the direct beam-induced signal. They detect cloud electrons migrating through an 18-mm-diameter pattern of small holes in the top of the chamber. A digitizing oscilloscope is used to record the signals, providing time-resolved information on cloud development. Carbon-coated, TiN-coated and uncoated aluminum chambers have been tested. Electron and positron beams of 2.1, 4.0 and 5.3 GeV with a variety of bunch populations and spacings in steps of 4 and 14 ns have been used. Here we report on results from the ECLOUD modeling code which highlight the sensitivity of these measurements to the physical phenomena determining cloud buildup such as the photoelectron produ...

  9. Direct nano-patterning of graphene with helium ion beams

    International Nuclear Information System (INIS)

    Naitou, Y.; Iijima, T.; Ogawa, S.

    2015-01-01

    Helium ion microscopy (HIM) was used for direct nano-patterning of single-layer graphene (SLG) on SiO 2 /Si substrates. This technique involves irradiation of the sample with accelerated helium ions (He + ). Doses of 2.0 × 10 16  He +  cm −2 from a 30 kV beam induced a metal-insulator transition in the SLG. The resolution of HIM patterning on SLG was investigated by fabricating nanoribbons and nanostructures. Analysis of scanning capacitance microscopy measurements revealed that the spatial resolution of HIM patterning depended on the dosage of He + in a non-monotonic fashion. Increasing the dose from 2.0 × 10 16 to 5.0 × 10 16  He +  cm −2 improved the spatial resolution to several tens of nanometers. However, doses greater than 1.0 × 10 17  He +  cm −2 degraded the patterning characteristics. Direct patterning using HIM is a versatile approach to graphene fabrication and can be applied to graphene-based devices

  10. Embodied intersubjective engagement in mother-infant tactile communication: a cross-cultural study of Japanese and Scottish mother-infant behaviors during infant pick-up.

    Science.gov (United States)

    Negayama, Koichi; Delafield-Butt, Jonathan T; Momose, Keiko; Ishijima, Konomi; Kawahara, Noriko; Lux, Erin J; Murphy, Andrew; Kaliarntas, Konstantinos

    2015-01-01

    This study examines the early development of cultural differences in a simple, embodied, and intersubjective engagement between mothers putting down, picking up, and carrying their infants between Japan and Scotland. Eleven Japanese and ten Scottish mothers with their 6- and then 9-month-old infants participated. Video and motion analyses were employed to measure motor patterns of the mothers' approach to their infants, as well as their infants' collaborative responses during put-down, pick-up, and carry phases. Japanese and Scottish mothers approached their infants with different styles and their infants responded differently to the short duration of separation during the trial. A greeting-like behavior of the arms and hands was prevalent in the Scottish mothers' approach, but not in the Japanese mothers' approach. Japanese mothers typically kneeled before making the final reach to pick-up their children, giving a closer, apparently gentler final approach of the torso than Scottish mothers, who bent at the waist with larger movements of the torso. Measures of the gap closure between the mothers' hands to their infants' heads revealed variably longer duration and distance gap closures with greater velocity by the Scottish mothers than by the Japanese mothers. Further, the sequence of Japanese mothers' body actions on approach, contact, pick-up, and hold was more coordinated at 6 months than at 9 months. Scottish mothers were generally more variable on approach. Measures of infant participation and expressivity indicate more active participation in the negotiation during the separation and pick-up phases by Scottish infants. Thus, this paper demonstrates a culturally different onset of development of joint attention in pick-up. These differences reflect cultures of everyday interaction.

  11. Embodied intersubjective engagement in mother–infant tactile communication: a cross-cultural study of Japanese and Scottish mother–infant behaviors during infant pick-up

    Science.gov (United States)

    Negayama, Koichi; Delafield-Butt, Jonathan T.; Momose, Keiko; Ishijima, Konomi; Kawahara, Noriko; Lux, Erin J.; Murphy, Andrew; Kaliarntas, Konstantinos

    2015-01-01

    This study examines the early development of cultural differences in a simple, embodied, and intersubjective engagement between mothers putting down, picking up, and carrying their infants between Japan and Scotland. Eleven Japanese and ten Scottish mothers with their 6- and then 9-month-old infants participated. Video and motion analyses were employed to measure motor patterns of the mothers’ approach to their infants, as well as their infants’ collaborative responses during put-down, pick-up, and carry phases. Japanese and Scottish mothers approached their infants with different styles and their infants responded differently to the short duration of separation during the trial. A greeting-like behavior of the arms and hands was prevalent in the Scottish mothers’ approach, but not in the Japanese mothers’ approach. Japanese mothers typically kneeled before making the final reach to pick-up their children, giving a closer, apparently gentler final approach of the torso than Scottish mothers, who bent at the waist with larger movements of the torso. Measures of the gap closure between the mothers’ hands to their infants’ heads revealed variably longer duration and distance gap closures with greater velocity by the Scottish mothers than by the Japanese mothers. Further, the sequence of Japanese mothers’ body actions on approach, contact, pick-up, and hold was more coordinated at 6 months than at 9 months. Scottish mothers were generally more variable on approach. Measures of infant participation and expressivity indicate more active participation in the negotiation during the separation and pick-up phases by Scottish infants. Thus, this paper demonstrates a culturally different onset of development of joint attention in pick-up. These differences reflect cultures of everyday interaction. PMID:25774139

  12. Boundary element analysis of the directional sensitivity of the concentric EMG electrode

    DEFF Research Database (Denmark)

    Henneberg, Kaj-åge; R., Plonsey

    1993-01-01

    on the intrinsic features linked to the geometry of the electrode. The results show that the cannula perturbs the potential distribution significantly. The core and the cannula electrodes measure potentials of the same order of magnitude in all of the pick-up range, except adjacent to the central wire, where...... as the mutual electrical influence between the electrode surfaces. A three-dimensional sensitivity function is defined from which information about the preferential direction of sensitivity, blind spots, phase changes, rate of attenuation, and range of pick-up radius can be derived. The study focuses...... the latter dominates the sensitivity function. The preferential directions of sensitivity are determined by.the amount of geometric offset between the individual sensitivity functions of the core and the cannula. The sensitivity function also reveals a complicated pattern of phase changes in the pick...

  13. Receivers for processing electron beam pick-up electrode signals

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    There are several methods of determining the transverse position of the electron beam, based upon sensing either the electric field, the magnetic field, or both. At the NSLS the transverse beam position monitors each consist of a set of four circular electrodes. There are 48 sets of pick-up electrodes in the X-ray ring and 24 in the VUV storage ring for determining the electron orbit, and a few extra sets installed for specialized purposes. When the beam passes between the four electrodes, charge is induced on each electrode, the amount depending upon the distance of the beam from that electrode. If V a , V b , V c and V d given by a difference between pairs of electrodes normalized for variations in beam current by dividing by the sum of electrode voltages. The method of processing these signals depends upon their time structure. The electrons circulating around the vacuum chamber are concentrated in short bunches within stability buckets produced by the accelerating voltage in the RF cavities. The charges induced on the pickup electrodes then are narrow pulses, a fraction of a nanosecond long, and would result in a monopolar voltage pulses if it were not for the impedance of the cable connecting the electrode to the processing apparatus. The capacitance between each electrode and the chamber wall is only a few picofarads and is effectively in parallel with the cable impedance (50 ohms). Thus an appreciable amount of the charge flows off the electrode while the bunch is between the electrodes, resulting in potential of opposite sign as the bunch is leaving the vicinity of the electrode. The resulting signal consists of a series of bipolar pulses, each of less than one nanosecond duration

  14. Final version of the pick-up wheels in the Pelletron tandem accelerator at Lund

    International Nuclear Information System (INIS)

    Hakansson, K.; Hellborg, R.

    1993-01-01

    A new type of pick-up wheel has been designed and constructed for the charge transport system of the Lund 3UDH Pelletron tandem accelerator. The major improvements compared with older types are a slender design with only one ball bearing and more robust contact pins with a rubber ring between the pinhead and the wheel nave. (orig.)

  15. Direct cryosorption pumping of an energetic hydrogen ion beam

    International Nuclear Information System (INIS)

    Schwenterly, S.W.; Ryan, P.M.; Tsai, C.C.

    1979-01-01

    Cryosorption pumps (CSP) are a prime candidate for the pumping of helium and deuterium-tritium (D-T) in tokamak divertor systems and may also see service in neutral beam injectors. However, the ability of a CSP to take high energy ions escaping from a plasma or neutral beam has not previously been demonstrated. In this study we arranged a 10-cm ion source of the type used in the Oak Ridge Tokamak (ORMAK) to inject a beam of ions directly into the inlet of a CSP. The pump contained two chevron baffles at 100K and 15K as well as a 15K cryosorption surface covered with a type 5A molecular sieve. The cryosurfaces were cooled by a closed-cycle helium refrigerator. For hydrogen ion pulses up to 11.5-keV energy and 1.3-A current, the pressure maintained during the pulse was only a few percent higher than that maintained with an equal flow of cold neutral gas. Pulse lengths of 100-300 ms were used. Calorimetric measurements showed that 40-60% of the I-V power was incident on the pump inlet. Cool-down and regeneration behavior of the pump will also be discussed

  16. Template-directed synthesis of oligoguanylic acids - Metal ion catalysis

    Science.gov (United States)

    Bridson, P. K.; Fakhrai, H.; Lohrmann, R.; Orgel, L. E.; Van Roode, M.

    1981-01-01

    The effects of Zn(2+), Pb(2+) and other metal ions on the efficiency and stereo-selectivity of the template-directed oligomerization of guanosine 5'-phosphorimidazolide are investigated. Reactions were run in the presence of a polyC template in a 2,6-lutidine buffer, and products analyzed by high-performance liquid chromatography on an RPC-5 column. The presence of the Pb(2+) ion is found to lead to the formation of 2'-5' linked oligomers up to the 40-mer, while Zn(2+) favors the formation of predominantly 3'-5' linked oligomers up to the 35-mer. When amounts of uracil, cytidine or adenosine 5'-phosphorimidazole equal to those of the guanosine derivative are included in the reaction mixture, the incorrect base is incorporated into the oligomer about 10% of the time with a Pb(2+) catalyst, but less than 0.5% of the time with Zn(2+). The Sn(2+), Sb(3+) and Bi(3+) ions are also found to promote the formation of 2'-5' oligomers, although not as effectively as Pb(2+), while no metal ions other than Zn(2+) promote the formation of the 3'-5' oligomers. The results may be important for the understanding of the evolution of nucleic acid replication in the absence of enzymes.

  17. 49 CFR 1242.76 - Administration; pickup and delivery, marine line haul, and rail substitute service; loading...

    Science.gov (United States)

    2010-10-01

    ... haul, and rail substitute service; loading, unloading and local marine; protective services; freight... SEPARATION OF COMMON OPERATING EXPENSES BETWEEN FREIGHT SERVICE AND PASSENGER SERVICE FOR RAILROADS 1 Operating Expenses-Transportation § 1242.76 Administration; pickup and delivery, marine line haul, and rail...

  18. Direct nano-patterning of graphene with helium ion beams

    Energy Technology Data Exchange (ETDEWEB)

    Naitou, Y., E-mail: yu-naitou@aist.go.jp [Nanoelectronics Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-1-1 Higashi, Tsukuba 305-8562 (Japan); Iijima, T.; Ogawa, S. [Nanoelectronics Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 16-1 Onogawa, Tsukuba 305-8569 (Japan)

    2015-01-19

    Helium ion microscopy (HIM) was used for direct nano-patterning of single-layer graphene (SLG) on SiO{sub 2}/Si substrates. This technique involves irradiation of the sample with accelerated helium ions (He{sup +}). Doses of 2.0 × 10{sup 16 }He{sup + }cm{sup −2} from a 30 kV beam induced a metal-insulator transition in the SLG. The resolution of HIM patterning on SLG was investigated by fabricating nanoribbons and nanostructures. Analysis of scanning capacitance microscopy measurements revealed that the spatial resolution of HIM patterning depended on the dosage of He{sup +} in a non-monotonic fashion. Increasing the dose from 2.0 × 10{sup 16} to 5.0 × 10{sup 16 }He{sup + }cm{sup −2} improved the spatial resolution to several tens of nanometers. However, doses greater than 1.0 × 10{sup 17 }He{sup + }cm{sup −2} degraded the patterning characteristics. Direct patterning using HIM is a versatile approach to graphene fabrication and can be applied to graphene-based devices.

  19. Longitudinal schottky spectra of a bunched Ne10+ ion beam at the CSRe

    International Nuclear Information System (INIS)

    Wen Weiqiang; Ma Xinwen; Zhang Dacheng

    2013-01-01

    The longitudinal Schottky spectra of a radio-frequency (RF) bunched and electron cooled 22Ne 10+ ion beam at 70 MeV/u have been studied by a newly installed resonant Schottky pick-up at the experimental cooler storage ring (CSRe), at IMP. For an RF-bunched ion beam, a longitudinal momentum spread of Δp/p=1.6 × 10 -5 has been reached with less than 107 stored ions. The reduction of momentum spread compared with a coasting ion beam was observed from Schottky noise signal of the bunched ion beam. In order to prepare the future laser cooling experiment at the CSRe, the RF-bunching power was modulated at 25 th , 50 th and 75 th harmonic of the revolution frequency, effective bunching amplitudes were extracted from the Schottky spectrum analysis. Applications of Schottky noise for measuring beam lifetime with ultra-low intensity of ion beams are presented, and it is relevant to upcoming experiments on laser cooling of relativistic heavy ion beams and nuclear physics at the CSRe. (authors)

  20. Ion trap architectures and new directions

    Science.gov (United States)

    Siverns, James D.; Quraishi, Qudsia

    2017-12-01

    Trapped ion technology has seen advances in performance, robustness and versatility over the last decade. With increasing numbers of trapped ion groups worldwide, a myriad of trap architectures are currently in use. Applications of trapped ions include: quantum simulation, computing and networking, time standards and fundamental studies in quantum dynamics. Design of such traps is driven by these various research aims, but some universally desirable properties have lead to the development of ion trap foundries. Additionally, the excellent control achievable with trapped ions and the ability to do photonic readout has allowed progress on quantum networking using entanglement between remotely situated ion-based nodes. Here, we present a selection of trap architectures currently in use by the community and present their most salient characteristics, identifying features particularly suited for quantum networking. We also discuss our own in-house research efforts aimed at long-distance trapped ion networking.

  1. An Inventory-Routing Problem with Pickups and Deliveries Arising in the Replenishment of Automated Teller Machines

    NARCIS (Netherlands)

    van Anholt, Roel G.; Coelho, Leandro C.; Laporte, Gilbert; Vis, Iris F. A.

    The purpose of this paper is to introduce, model, and solve a rich multiperiod inventory-routing problem with pickups and deliveries motivated by the replenishment of automated teller machines in the Netherlands. Commodities can be brought to and from the depot, as well as being exchanged among

  2. An inventory-routing problem with pickups and deliveries arising in the replenishment of automated teller machines

    NARCIS (Netherlands)

    Van Anholt, Roel G.; Coelho, Leandro C.; Laporte, Gilbert; Vis, Iris F.A.

    2016-01-01

    The purpose of this paper is to introduce, model, and solve a rich multiperiod inventory-routing problem with pickups and deliveries motivated by the replenishment of automated teller machines in the Netherlands. Commodities can be brought to and from the depot, as well as being exchanged among

  3. Fluorescent carbon quantum dot hydrogels for direct determination of silver ions.

    Science.gov (United States)

    Cayuela, A; Soriano, M L; Kennedy, S R; Steed, J W; Valcárcel, M

    2016-05-01

    The paper reports for the first time the direct determination of silver ion (Ag(+)) using luminescent Carbon Quantum Dot hydrogels (CQDGs). Carbon Quantum Dots (CQDs) with different superficial moieties (passivate-CQDs with carboxylic groups, thiol-CQDs and amine-CQDs) were used to prepare hybrid gels using a low molecular weight hydrogelator (LMWG). The use of the gels results in considerable fluorescence enhancement and also markedly influences selectivity. The most selective CQDG system for Ag(+) ion detection proved to be those containing carboxylic groups onto their surface. The selectivity towards Ag(+) ions is possibly due to its flexible coordination sphere compared with other metal ions. This fluorescent sensing platform is based on the strong Ag-O interaction which can quench the photoluminescence of passivate-CQDs (p-CQDs) through charge transfer. The limit of detection (LOD) and quantification (LOQ) of the proposed method were 0.55 and 1.83µgmL(-1), respectively, being applied in river water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. Current control for magnetized plasma in direct-current plasma-immersion ion implantation

    International Nuclear Information System (INIS)

    Tang Deli; Chu, Paul K.

    2003-01-01

    A method to control the ion current in direct-current plasma-immersion ion implantation (PIII) is reported for low-pressure magnetized inductively coupled plasma. The ion current can be conveniently adjusted by applying bias voltage to the conducting grid that separates plasma formation and implantation (ion acceleration) zones without the need to alter the rf input power, gas flux, or other operating conditions. The ion current that diminishes with an increase in grid bias in magnetized plasmas can be varied from 48 to 1 mA by increasing the grid voltage from 0 to 70 V at -50 kV sample bias and 0.5 mTorr hydrogen pressure. High implantation voltage and monoenergetic immersion implantation can now be achieved by controlling the ion current without varying the macroscopic plasma parameters. The experimental results and interpretation of the effects are presented in this letter. This technique is very attractive for PIII of planar samples that require on-the-fly adjustment of the implantation current at high implantation voltage but low substrate temperature. In some applications such as hydrogen PIII-ion cut, it may obviate the need for complicated sample cooling devices that must work at high voltage

  5. Measurement of the mean radial position of a lead ion beam in the CERN PS

    CERN Document Server

    Belleman, J; González, J; Johnston, S; Schulte, E C; Thivent, E

    1996-01-01

    The intensity of the lead ion beam in the PS, nominally 4×108 charges of Pb53+ per bunch, is too low for the closed orbit measurement system. However, for successful acceleration it is sufficient to know the mean radial position (MRP). A system was thus designed for simultaneous acquisition of revolution frequency and magnetic field. The frequency measurement uses a direct digital synthesiser (DDS), phase-locked to the beam signal from a special high-sensitivity pick-up. The magnetic field is obtained from the so-called B-train. From these two values, the MRP is calculated. The precision depends on the frequency measurement and on the accuracy of the value for the magnetic field. Furthermore, exact knowledge of the transition energy is essential. This paper describes the hardware and software developed for the MRP system, and discusses the issue of calibration, with a proton beam, of the B measurement.

  6. A direct-measurement technique for estimating discharge-chamber lifetime. [for ion thrusters

    Science.gov (United States)

    Beattie, J. R.; Garvin, H. L.

    1982-01-01

    The use of short-term measurement techniques for predicting the wearout of ion thrusters resulting from sputter-erosion damage is investigated. The laminar-thin-film technique is found to provide high precision erosion-rate data, although the erosion rates are generally substantially higher than those found during long-term erosion tests, so that the results must be interpreted in a relative sense. A technique for obtaining absolute measurements is developed using a masked-substrate arrangement. This new technique provides a means for estimating the lifetimes of critical discharge-chamber components based on direct measurements of sputter-erosion depths obtained during short-duration (approximately 1 hr) tests. Results obtained using the direct-measurement technique are shown to agree with sputter-erosion depths calculated for the plasma conditions of the test. The direct-measurement approach is found to be applicable to both mercury and argon discharge-plasma environments and will be useful for estimating the lifetimes of inert gas and extended performance mercury ion thrusters currently under development.

  7. Direct Detection of the Ion Pair to Free Ions Transformation upon Complexation with an Ion Receptor in Non-Polar Solvents by using Conductometry.

    Science.gov (United States)

    Iseda, Kazuya; Kokado, Kenta; Sada, Kazuki

    2018-03-01

    In this study, we performed conductometry in various organic solvents to directly detect the transformation from tetrabutylammonium chloride ( TBACl ) ion-pair salt to the free ions through complexation with meso -octamethylcalix[4]pyrrole ( CP ), which is a well-known receptor for chloride anions. In the presence of CP , the conductivity of TBACl increases in various non-polar solvents, indicating that complexation with CP enhances the ionic dissociation of TBACl in such non-polar solvents. In other words, CP recognizes chloride as an ion-paired salt as well as a free anion in non-polar solvents. Additionally, the TBA(CP - Cl ) complex exhibited a considerably lower ion-pairing constant ( K ip ) than TBACl in non-polar solvents, resulting in enhanced conductivity. Based on these findings, we can conclude that complexation of an anion with a hydrophobic anion receptor will be useful for creating functional and stimuli-responsive soft materials in organic solvents using coulombic forces.

  8. Near-surface hydrogen depletion of diamond-like carbon films produced by direct ion deposition

    Science.gov (United States)

    Markwitz, Andreas; Gupta, Prasanth; Mohr, Berit; Hübner, René; Leveneur, Jerome; Zondervan, Albert; Becker, Hans-Werner

    2016-03-01

    Amorphous atomically flat diamond-like carbon (DLC) coatings were produced by direct ion deposition using a system based on a Penning ion source, butane precursor gas and post acceleration. Hydrogen depth profiles of the DLC coatings were measured with the 15N R-NRA method using the resonant nuclear reaction 1H(15N, αγ)12C (Eres = 6.385 MeV). The films produced at 3.0-10.5 kV acceleration voltage show two main effects. First, compared to average elemental composition of the film, the near-surface region is hydrogen depleted. The increase of the hydrogen concentration by 3% from the near-surface region towards the bulk is attributed to a growth model which favours the formation of sp2 hybridised carbon rich films in the film formation zone. Secondly, the depth at which the maximum hydrogen concentration is measured increases with acceleration voltage and is proportional to the penetration depth of protons produced by the ion source from the precursor gas. The observed effects are explained by a deposition process that takes into account the contributions of ion species, hydrogen effusion and preferential displacement of atoms during direct ion deposition.

  9. Multi-directional self-ion irradiation of thin gold films: A new strategy for achieving full texture control

    International Nuclear Information System (INIS)

    Seita, Matteo; Muff, Daniel; Spolenak, Ralph

    2011-01-01

    Highlights: → Multi-directional self-ion bombardment of Au films. → Extensive selective grain growth leads to single crystal-like films. → Texture rotation is prevented by the multi-directional irradiation process. → Texture rotation rate depends on the film initial defect density. - Abstract: Post-deposition ion bombardment can be employed to convert polycrystalline films into single crystals through a process of selective grain growth. Here we report a new technique that enables selective grain growth in self-ion bombarded gold films - a system in which the formation of large single crystal domains was prevented by the occurrence of ion-induced texture rotation. Our findings suggest that the extent of the texture rotation is a function of the ion fluence and the film initial microstructure.

  10. "Ion" B-Dot and Faraday Cup Results Located Inside The Cathode Knob Of The Self Magnetic Pinch (Smp) Diode (A New Diagnostic For Diode Behavior?)

    Energy Technology Data Exchange (ETDEWEB)

    Mazarakis, Michael G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kiefer, Mark L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Leckbee, Joshua J. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Nielsen, Dan S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ziska, Derek [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-08-01

    This paper describes our effort to measure the back-streaming ions emitted from the target x-ray convertor and thus estimate the ion contribution to the A-K gap bipolar current flow. Knowing the ion contribution is quite important in order to calculate the expected x-ray dose and compare it with the actual measurements. Our plans were first to measure the total ion current using B-dot monitors, Rogowski coils, and Faraday cups and then to utilize filtered Faraday cups and time of flight techniques to identify and measure the various ionic species. The kinetic energy (velocities) of the ions should help evaluate the actual voltage applied at the anode-cathode (A-K) gap. LSP simulations found that the most prominent ions are protons and carbon single plus (C+). For an 8-MV A-K voltage, the estimated proton current back-streaming through an 1 cm in diameter hollow cathode tip was on the average 3 kA and the carbon current 0.7 kA. Since only a small fraction of the ions will make it through the cylindrical aperture, the corresponding total currents were calculated to be respectively 25kA for proton and 7 kA for carbon ions, a quite substantial contribution to the total bipolar beam current. Hence, approximately only 10% of the total back-streaming ionic currents could make it through the hollow cathode tip aperture. Unfortunately the diagnostic cables connecting the Faraday cup and the B-dot monitors to the screen room scopes experienced a large amount of charge pick-up that obliterated our effort to directly measure those relatively small currents. However, we succeeded in measuring those currents indirectly with activation techniques [Contribution of the back-streaming ions to the self-magnetic pinch (SMP) diode Current., M. G. Mazarakis, M. G. Mazarakis, M. E. Cuneo, S. D. Fournier, M. D. Johnston, M. L. Kiefer, J. J. Leckbee, D. S. Nielsen, B.V.Oliver, M. E. Sceiford, S. C. Simpson, T. J. Renk, C. L. Ruiz, T. J. Webb, and D. Ziska. Subitted for publication.]. In

  11. Time-resolved Shielded-Pickup Measurements and Modeling of Beam Conditioning Effects on Electron Cloud Buildup at CesrTA

    CERN Document Server

    Crittenden, J A; Liu, X; Palmer, M A; Santos, S; Sikora, J P; Kato, S; Calatroni, S; Rumolo, G

    2012-01-01

    The Cornell Electron Storage Ring Test Accelerator program includes investigations into electron cloud buildup in vacuum chambers with various coatings. Two 1.1-mlong sections located symmetrically in the east and west arc regions are equipped with BPM-like pickup detectors shielded against the direct beam-induced signal. They detect cloud electrons migrating through an 18-mm-diameter pattern of 0.76 mm-diameter holes in the top of the chamber. A digitizing oscilloscope is used to record the signals, providing time-resolved information on cloud development. We present new measurements of the effect of beam conditioning on a newly-installed amorphous carbon coated chamber, as well as on an extensively conditioned chamber with a diamond-like carbon coating. The ECLOUD modeling code is used to quantify the sensitivity of these measurements to model parameters, differentiating between photoelectron and secondary-electron production processes.

  12. Direction-dependent RBS channelling studies in ion implanted LiNbO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Wendler, E., E-mail: elke.wendler@uni-jena.de; Becker, G.; Rensberg, J.; Schmidt, E.; Wolf, S.; Wesch, W.

    2016-07-15

    Damage formation in ion implanted LiNbO{sub 3} was studied by Rutherford backscattering spectrometry (RBS) along various directions of the LiNbO{sub 3} crystal. From the results obtained it can be unambiguously concluded that Nb atoms being displaced during ion implantation preferably occupy the free octahedron sites of the LiNbO{sub 3} lattice structure and most likely also form Nb{sub Li} antisite defects.

  13. Polarization of {sup 23}Ne, {sup 24m,25}Al and {sup 28}P produced through single nucleon pickup and charge-exchange reactions at 100 AMeV

    Energy Technology Data Exchange (ETDEWEB)

    Ohtsubo, T., E-mail: tohtsubo@np.gs.niigata-u.ac.jp; Hirano, H.; Takahashi, S. [Niigata Univ. (Japan); Matsuta, K.; Mihara, M.; Fukuda, M. [Osaka Univ. (Japan); Nagatomo, T. [RIKEN (Japan); Izumikawa, T. [Niigata Univ., RI Center (Japan); Momota, S. [Kochi Univ. of Tech. (Japan); Nishimura, D.; Komurasaki, J.; Ishikawa, D. [Osaka Univ. (Japan); Zhou, D. M.; Zheng, Y. N.; Zhu, S. Y. [China Institute of Atomic Energy (China); Kitagawa, A.; Kanazawa, M.; Torikoshi, M.; Sato, S. [Inage-ku, NIRS (Japan); Minamisono, T. [Fukui Univ. of Tech. (Japan)

    2007-11-15

    We measured the polarization of the {beta}-emitting {sup 23}Ne (I{sup {pi}} 5/2{sup +}, T{sub 1/2} = 37.24 s) and {sup 25}Al(I{sup {pi}} = 5/2{sup +}, T{sub 1/2} = 7.18 s) produced through the one nucleon pickup reactions and {sup 24m}Al(I{sup {pi}} = 1{sup +}, T{sub 1/2} 131 ms, E{sub ex} = 426 keV) and {sup 28}P(I{sup {pi}} = 3{sup +}, T{sub 1/2} = 270 ms) produced through charge-exchange reactions in the intermediate energy heavy ion collisions. We compared them with those from the projectile fragmentation process. The larger polarization seems to persistently be positive throughout the momentum distribution, and sharper momentum distributions suggest that nuclear friction mechanism is responsible for the polarization phenomena.

  14. Direct determination of recoil ion detection efficiency for coincidence time-of-flight studies of molecular fragmentation

    International Nuclear Information System (INIS)

    Ben-Itzhak, I.; Carnes, K.D.; Ginther, S.G.; Johnson, D.T.; Norris, P.J.; Weaver, O.L.

    1993-01-01

    Molecular fragmentation of diatomic and small polyatomic molecules caused by fast ion impact has been studied. The evaluation of the cross sections of the different fragmentation channels depends strongly on the recoil ion detection efficiency, ε r (single ions proportional to ε r , and ion pairs to ε 2 r , etc.). A method is suggested for the direct determination of this detection efficiency. This method is based on the fact that fast H + + CH 4 collisions produce C 2+ fragments only in coincidence with H + and H + 2 fragments, that is, there is a negligible number of C 2+ singles, if any. The measured yield of C 2+ singles is therefore due to events in which the H + m of the H + m + C 2+ ion pair was not detected and thus is proportional to 1 - ε r . Methane fragmentation caused by 1 MeV proton impact is used to evaluate directly the recoil ion detection efficiency and to demonstrate the method of deriving the cross sections of all breakup channels. (orig.)

  15. Direct measurement of the concentration of metastable ions produced from neutral gas particles using laser-induced fluorescence

    Science.gov (United States)

    Chu, Feng; Skiff, Fred; Berumen, Jorge; Mattingly, Sean; Hood, Ryan

    2017-10-01

    Extensive information can be obtained on wave-particle interactions and wave fields by direct measurement of perturbed ion distribution functions using laser-induced fluorescence (LIF). For practical purposes, LIF is frequently performed on metastables that are produced from neutral gas particles and existing ions in other electronic states. We numerically simulate the ion velocity distribution measurement and wave-detection process using a Lagrangian model for the LIF signal. The results show that under circumstances where the metastable ion population is coming directly from the ionization of neutrals (as opposed to the excitation of ground-state ions), the velocity distribution will only faithfully represent processes which act on the ion dynamics in a time shorter than the metastable lifetime. Therefore, it is important to know the ratio of metastable population coming from neutrals to that from existing ions to correct the LIF measurements of plasma ion temperature and electrostatic waves. In this paper, we experimentally investigate the ratio of these two populations by externally launching an ion acoustic wave and comparing the wave amplitudes that are measured with LIF and a Langmuir probe using a lock-in amplifier. DE-FG02-99ER54543.

  16. Near-surface hydrogen depletion of diamond-like carbon films produced by direct ion deposition

    Energy Technology Data Exchange (ETDEWEB)

    Markwitz, Andreas, E-mail: A.Markwitz@gns.cri.nz [GNS Science, Lower Hutt (New Zealand); The MacDiarmid Institute for Advanced Materials and Nanotechnology (New Zealand); Gupta, Prasanth [GNS Science, Lower Hutt (New Zealand); The MacDiarmid Institute for Advanced Materials and Nanotechnology (New Zealand); Mohr, Berit [GNS Science, Lower Hutt (New Zealand); Hübner, René [Institute of Ion Beam Physics and Materials Research, Helmholtz-Zentrum Dresden-Rossendorf (Germany); Leveneur, Jerome; Zondervan, Albert [GNS Science, Lower Hutt (New Zealand); Becker, Hans-Werner [RUBION, Ruhr-University Bochum (Germany)

    2016-03-15

    Amorphous atomically flat diamond-like carbon (DLC) coatings were produced by direct ion deposition using a system based on a Penning ion source, butane precursor gas and post acceleration. Hydrogen depth profiles of the DLC coatings were measured with the 15N R-NRA method using the resonant nuclear reaction {sup 1}H({sup 15}N, αγ){sup 12}C (E{sub res} = 6.385 MeV). The films produced at 3.0–10.5 kV acceleration voltage show two main effects. First, compared to average elemental composition of the film, the near-surface region is hydrogen depleted. The increase of the hydrogen concentration by 3% from the near-surface region towards the bulk is attributed to a growth model which favours the formation of sp{sup 2} hybridised carbon rich films in the film formation zone. Secondly, the depth at which the maximum hydrogen concentration is measured increases with acceleration voltage and is proportional to the penetration depth of protons produced by the ion source from the precursor gas. The observed effects are explained by a deposition process that takes into account the contributions of ion species, hydrogen effusion and preferential displacement of atoms during direct ion deposition.

  17. Directed flow of baryons in heavy-ion collisions

    International Nuclear Information System (INIS)

    Ivanov, Yu.B.; Nikonov, E.G.; Toneev, V.D.; Noerenberg, W.; Shanenko, A.A.

    2000-11-01

    The collective motion of nucleons from high-energy heavy-ion collisions is analyzed within a relativistic two-fluid model for different equations of state (EoS). As function of beam energy the theoretical slope parameter F y of the differential directed flow is in good agreement with experimental data, when calculated for the QCD-consistent EoS described by the statistical mixed-phase model. Within this model, which takes the deconfinement phase transition into account, the excitation function of the directed flow left angle P x right angle turns out to be a smooth function in the whole range from SIS till SPS energies. This function is close to that for pure hadronic EoS and exhibits no minimum predicted earlier for a two-phase bag-model EoS. Attention is also called to a possible formation of nucleon antiflow (F y or∼100 A.GeV. (orig.)

  18. Charge exchange studies with Gold ions at the Brookhaven Booster and AGS

    International Nuclear Information System (INIS)

    Ahrens, L.A.; Hseuh, H.C.; Roser, T.

    1994-01-01

    Efficient acceleration of Gold ions to ll GeV/nucleon places strong constraints on the vacuum and also on the choice of thickness and material of the necessary stripping foils. Results of a number of detailed experimental studies performed with the Gold beam at the Brookhaven Booster and AGS to determine the relevant electron stripping and pick-up probabilities are presented. Of particular interest is the lifetime of the relatively low energy, partially stripped Gold beam in the Booster and the stripping efficiency to Helium-like AU +77 for injection into the AGS

  19. EFFECT OF ION ∇ B DRIFT DIRECTION ON TURBULENCE FLOW AND FLOW SHEAR

    International Nuclear Information System (INIS)

    FENZI, C; McKEE, G.R; BURRELL, K.H; CARLSTROM, T.N; FONCK, R.J; GROEBNER, R.J

    2003-01-01

    The divertor magnetic geometry has a significant effect on the poloidal flow and resulting flow shear of turbulence in the outer region of L-mode tokamak plasmas, as determined via two-dimensional measurements of density fluctuations with Beam Emission Spectroscopy on DIII-D. Plasmas with similar parameters, except that in one case the ion (del)B drift points towards the divertor X-point (lower single-null, LSN), and in the other case, the ion (del)B drift points away from the divertor X-point (upper single-null, USN), are compared. Inside of r/a=0.9, the turbulence characteristics (amplitude, flow direction, correlation lengths) are similar in both cases, while near r/a=0.92, a dramatic reversal of the poloidal flow of turbulence relative to the core flow direction is observed in plasmas with the ion (del)B drift pointing towards the divertor X-point. No such flow reversal is observed in plasmas with the ion (del)B drift pointing away from the divertor X-point. This poloidal flow reversal results in a significantly larger local shear in the poloidal turbulence flow velocity in plasmas with the ion (del)B drift pointing towards the divertor X-point. Additionally, these plasmas locally exhibit significant dispersion, with two distinct and counter-propagating turbulence modes. Likewise, the radial correlation length of the turbulence is reduced in these plasmas, consistent with biorthogonal decomposition measurements of dominant turbulence structures. The naturally occurring turbulence flow shear in these LSN plasmas may facilitate the LH transition that occurs at an input power of roughly one-half to one-third that of corresponding plasmas with the ion (del)B drift pointing away from the X-point

  20. Simulated annealing with restart strategy for the blood pickup routing problem

    Science.gov (United States)

    Yu, V. F.; Iswari, T.; Normasari, N. M. E.; Asih, A. M. S.; Ting, H.

    2018-04-01

    This study develops a simulated annealing heuristic with restart strategy (SA_RS) for solving the blood pickup routing problem (BPRP). BPRP minimizes the total length of the routes for blood bag collection between a blood bank and a set of donation sites, each associated with a time window constraint that must be observed. The proposed SA_RS is implemented in C++ and tested on benchmark instances of the vehicle routing problem with time windows to verify its performance. The algorithm is then tested on some newly generated BPRP instances and the results are compared with those obtained by CPLEX. Experimental results show that the proposed SA_RS heuristic effectively solves BPRP.

  1. Direct Measurement of Neutral/Ion Beam Power using Thermocouple Analysis

    International Nuclear Information System (INIS)

    Day, I.; Gee, S.

    2006-01-01

    Modern Neutral Beam Injection systems such as those used on JET and MAST routinely use thermocouples embedded close to the surface of beam stopping elements, such as calorimeters and ion dumps, coupled to high speed data acquisition systems to determine beam profile and position from temperature rise data. With the availability of low cost data acquisition and storage systems it is now possible to record data from all thermocouples in a fully instrumented calorimeter or ion dump on 20 ms timescales or better. This sample rate is sufficiently fast to enable the thermocouple data to be used to calculate the incident power density from 1d heat transfer theory. This power density data coupled with appropriate Gaussian fits enables the determination of the 2d beam profile and thus allows an instantaneous and direct measurement of beam power. The theory and methodology required to analyse the fast thermocouple data from the MAST calorimeter and residual ion dump thermocouples is presented and direct measurements of beam power density are demonstrated. The power of desktop computers allows such analysis to be carried out virtually instantaneously. The methods used to automate this analysis are discussed in detail. A code, utilising the theory and methodology, has been developed to allow immediate measurements of beam power on a pulse by pulse basis. The uncertainty in determining the beam power density is shown to be less than 10 %. This power density data is then fitted to a 2d Gaussian beam profile and integrated to establish the total beam power. Results of this automated analysis for the neutral beam and residual ion power of the MAST duopigatron and PINI NBI systems are presented. This technology could be applied to a beam power safety interlock system. The application to a beam shine through protection system for the inner wall of the JET Tokamak is discussed as an example. (author)

  2. Direct Reaction Experimental Studies with Beams of Radioactive Tin Ions

    Energy Technology Data Exchange (ETDEWEB)

    Jones, K. L. [University of Tennessee, Knoxville (UTK); Ahn, S.H. [University of Tennessee, Knoxville (UTK); Allmond, James M [ORNL; Ayres, A. [University of Tennessee, Knoxville (UTK); Bardayan, Daniel W [ORNL; Baugher, T. [Michigan State University, East Lansing; Bazin, D. [Michigan State University, National Superconducting Cyclotron Laboratory (NSCL); Beene, James R [ORNL; Berryman, J. S. [Michigan State University, East Lansing; Bey, A. [University of Tennessee, Knoxville (UTK); Bingham, C. R. [University of Tennessee, Knoxville (UTK); Cartegni, L. [University of Tennessee, Knoxville (UTK); Chae, K. Y. [University of Tennessee, Knoxville (UTK)/Sungkyunkwan University, Korea; Cizewski, J. A. [Rutgers University; Gade, A. [Michigan State University, National Superconducting Cyclotron Laboratory (NSCL); Galindo-Uribarri, Alfredo {nmn} [ORNL; Garcia-Ruiz, R.F. [Instituut voor Kernen Stralingsfysica, KU Leuven, B-3001, Leuven, Belgium; Grzywacz, Robert Kazimierz [ORNL; Howard, Meredith E [ORNL; Kozub, R. L. [Tennessee Technological University (TTU); Liang, J Felix [ORNL; Manning, Brett M [ORNL; Matos, M. [Louisiana State University; McDaniel, S. [Michigan State University, East Lansing; Miller, D. [University of Tennessee, Knoxville (UTK); Nesaraja, Caroline D [ORNL; O' Malley, Patrick [Rutgers University; Padgett, S [University of Tennessee, Knoxville (UTK); Padilla-Rodal, Elizabeth [Universidad Nacional Autonoma de Mexico (UNAM); Pain, Steven D [ORNL; Pittman, S. T. [University of Tennessee (UTK) and Oak Ridge National Laboratory (ORNL); Radford, David C [ORNL; Ratkiewicz, Andrew J [ORNL; Schmitt, Kyle [ORNL; Smith, Michael Scott [ORNL; Stracener, Daniel W [ORNL; Stroberg, S. [Michigan State University, East Lansing; Tostevin, Jeffrey A [ORNL; Varner Jr, Robert L [ORNL; Weisshaar, D. [Michigan State University, East Lansing; Wimmer, K. [Michigan State University, National Superconducting Cyclotron Laboratory (NSCL)/Central Michigan University; Winkler, R. [Michigan State University, East Lansing

    2015-01-01

    The tin chain of isotopes provides a unique region in which to investigate the evolution of single-particle structure, spreading from N = 50 at Sn-100, through 10 stable isotopes and the N = 82 shell closure at Sn-132 out into the r-process path. Direct reactions performed on radioactive ion beams are sensitive spectroscopic tools for studying exotic nuclei. Here we present one experiment knocking out neutrons from tin isotopes that are already neutron deficient and two reactions that add a neutron to neutron-rich Sn-130. Both techniques rely on selective particle identification and the measurement of gamma rays in coincidence with charged ions. We present the goals of the two experiments and the particle identification for the channels of interest. The final results will be presented in future publications.

  3. Direct extraction of negative lithium ions from a lithium plasma

    International Nuclear Information System (INIS)

    Wada, M.; Tsuda, H.; Sasao, M.

    1990-01-01

    Negative lithium ions (Li - ) were directly extracted from a lithium plasma in a multiline cusp plasma container. A pair of permanent magnets mounted near the extractor electrode created the filter magnetic field that separated the extraction region plasma from the main discharge plasma. The plasma electrode facing the extraction region plasma was biased with respect to the other parts of the chamber wall, which acted as discharge anodes. The larger filter magnetic field resulted larger Li - current. When the bias to the plasma electrode was several volts positive against the anode potential, extracted Li - current took the maximum for a fixed strength of the filter field. These dependences of Li - upon the filter magnetic field and the plasma electrode bias are similar to the ones of negative hydrogen ions

  4. Paul Trapping of Radioactive 6He+ Ions and Direct Observation of Their β Decay

    International Nuclear Information System (INIS)

    Flechard, X.; Lienard, E.; Mery, A.; Rodriguez, D.; Ban, G.; Durand, D.; Duval, F.; Herbane, M.; Labalme, M.; Mauger, F.; Naviliat-Cuncic, O.; Velten, Ph.; Thomas, J. C.

    2008-01-01

    We demonstrate that abundant quantities of short-lived β unstable ions can be trapped in a novel transparent Paul trap and that their decay products can directly be detected in coincidence. Low energy 6 He + (807 ms half-life) ions were extracted from the SPIRAL source at GANIL, then decelerated, cooled, and bunched by means of the buffer gas cooling technique. More than 10 8 ions have been stored over a measuring period of six days, and about 10 5 decay coincidences between the beta particles and the 6 Li ++ recoiling ions have been recorded. The technique can be extended to other short-lived species, opening new possibilities for trap assisted decay experiments

  5. The effect of Fe and C in modifying deuterium pickup in Zr-2.5Nb: a response surface analysis

    International Nuclear Information System (INIS)

    Ploc, R.A.

    2001-03-01

    A Response Surface Analysis of the effect of iron and carbon in Zr-2.5Nb-Fe/C drop-castings has shown that iron and carbon have at least a quadratic, synergistic relationship on oxidation and deuterium pickup. Tests were performed in the Halden test reactor and associated autoclave for 208 days at 598 K (325 o C). The synergism explains why pressure tube data have limited value when attempting to deduce the effect of impurity elements on pick up. Out- and in-reactor pick up were similar in trend and magnitude except for the in-reactor deuterium pickup, which was about one-quarter of that out-reactor. Minimum in-reactor deuterium ingress is predicted for 30 ppm (wt) carbon and approximately 1,100 ppm (wt) of iron. Out-reactor optimal values are similar but with slightly higher iron values. (author)

  6. The Hydrogen Pickup Behavior for Zirconium-based Alloys in Various Out-of-pile Corrosion Test Conditions

    Energy Technology Data Exchange (ETDEWEB)

    Aomi, M.; Etoh, Y.; Ishimoto, S.; Une, K. [Nippon Nuclear Fuel Development, Co., Ltd., 2163 Narita-cho, Oarai-machi, Ibaraki-ken, 311-1313 (Japan); Ito, K. [Global Nuclear Fuel Japan Co., Ltd., 3-1 Uchikawa 2-chome, Yokosuka-shi, Kanagawa-ken, 239-0836 (Japan)

    2009-06-15

    An acceleration of hydrogen absorption in zirconium alloy claddings at high burnups is one of the most important issues limiting the fuel performance from the viewpoint of cladding integrity. In this context, advanced cladding materials with higher corrosion resistant and lower hydrogen absorption properties have been widely searched in various organizations. In this study, four kinds of zirconium-based alloys, whose in-pile data had been acquired [1,2] were subjected to comprehensive out-of-pile corrosion tests with various temperature and atmosphere conditions in order to investigate the correlation between in-pile and out-of-pile corrosion and hydrogen pick-up behavior, i.e. Zry-2, GNF-Ziron (Zry-2-based alloy with {approx}0.25 wt % of Fe), Hi-FeNi Zircaloy (Zry-2-based alloy with {approx}0.25 wt % of Fe and {approx}0.1 wt% Ni), and VB (Zr-based alloy containing Sn, Cr, and {approx}0.5 wt % of Fe). All the alloys were annealed in RXA condition. The out-of-pile corrosion tests were carried out in three different conditions of 400 deg. C steam, 475 deg. C supercritical water, and 290 deg. C LiOH aqueous solution. In addition to these alloys, several Zry-2-based alloys with various iron contents were tested in 290 deg. C LiOH aqueous solution. Among the four corrosion conditions, the 290 deg. C LiOH aqueous solution test well screened the hydrogen pick-up behavior of the alloys. The hydrogen absorption decreased with higher iron contents in the alloys in both the out-of-pile and in-pile conditions. Especially, the distinct suppression of hydrogen absorption was observed for VB with the highest iron content. The similar dependence of iron content on the hydrogen pick-up fraction was also obtained for the Zry-2-based alloys with different iron contents, which were corroded in the 290 deg. C LiOH aqueous solution condition. As for the corrosion behavior in the 290 deg. C LiOH aqueous solution condition, the weight gains of Zry-2, GNF-Ziron and VB followed the 1

  7. On measuring the UNK SC-dipole bending strength with rotating pick-up coil

    International Nuclear Information System (INIS)

    Smirnov, N.L.; Tikhov, A.V.

    1993-01-01

    The experience in measuring the SC-dipole bending strength with the spotting method shown this measurement to be the most complicated and expensive. A convenient and simple method of rotating pick-up coil, which can not provide the required accuracy, may be used for this measurement combined with NMR measurements in the dipole central part. The physical ground and description of the method are given in the paper. The analysis of the errors and measurement results of the SPDMI SC-dipoles are presented. 9 refs..; 7 figs

  8. Quantitative assessment of the ion-beam irradiation induced direct damage of nucleic acid bases through FTIR spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Qing, E-mail: huangq@ipp.ac.cn [Key Laboratory of Ion Beam Bio-engineering, Institute of Technical Biology and Agriculture Engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences (China); University of Science and Technology of China, Hefei 230029, Anhui (China); Su, Xi; Yao, Guohua; Lu, Yilin; Ke, Zhigang; Liu, Jinghua; Wu, Yuejin; Yu, Zengliang [Key Laboratory of Ion Beam Bio-engineering, Institute of Technical Biology and Agriculture Engineering, Hefei Institutes of Physical Science, Chinese Academy of Sciences (China)

    2014-07-01

    Energetic particles exist ubiquitously in nature, and when they hit DNA molecules in organisms, they may induce critical biological effects such as mutation. It is however still a challenge to measure directly and quantitatively the damage imposed by the energetic ions on target DNA molecules. In this work we attempted to employ Fourier transformation infrared (FTIR) spectroscopy to assess the ion-induced direct damage of four nucleic acid bases, namely, thymine (T), cytosine (C), guanine (G), and adenine (A), which are the building blocks of DNA molecules. The samples were prepared as thin films, irradiated by argon ion-beams at raised ion fluences, and in the meantime measured by FTIR spectroscopy for the damage in a quasi-in-situ manner. It was found that the low-energy ion-beam induced radiosensitivity of the four bases shows the sequence G > T > C > A, wherein the possible mechanism was also discussed.

  9. An analysis of plasma ion toroidal rotation during large amplitude MHD activity in JET

    International Nuclear Information System (INIS)

    Snipes, J.A.; Esch, H.P.L. de; Lazzaro, E.; Stork, D.; Hellermann, M. von; Galvao, R.; Hender, T.C.; Zasche, D.

    1989-01-01

    A detailed study of plasma ion toroidal rotation in JET during large amplitude MHD activity has revealed a strong viscous force that couples plasma ions to MHD modes. Depending on the MHD modes present, this force can couple across all of the plasma cross section, across only the central region, roughly within the q=1 surface, or across only the outer region outside the q=1.5 surface. The force acts to flatten the ion toroidal rotation frequency profile, measured by the JET active charge exchange spectroscopy diagnostic, across the coupled region of plasma. The frequency of rotation in this region agrees with the MHD oscillation frequency measured by magnetic pick-up coils at the wall. The strength of the force between the ions and modes becomes evident during high power NBI when the mode locks and drags the ion toroidal rotation frequency to zero, within the errors of the measurements. The present theories of plasma rotation either ignore MHD effects entirely, consider only moderate n toroidal field ripple, or low n ripple effects. (author) 7 refs., 3 figs

  10. Investigating Global Ion and Neutral Atom Populations with IBEX and Voyager

    Science.gov (United States)

    Florinski, Vladimir

    2016-01-01

    The main objective of this project was to investigate pickup ion (PUI) production in the solar wind and heliosheath (the region between the termination shock and the heliopause) and compute the distributed energetic neutral atom fluxes throughout the helioshpere. The simulations were constrained by comparing the model output against observations from Ulysses, New Horizons, Voyager 1 and 2, and IBEX space probes. As evidenced by the number of peer reviewed journal publications resulting from the project (13 plus three submitted) and their citation rate (156 citations over three years), the project has made a lasting contribution to the field. The outcome is a significant improvement of our understanding of the pickup ion production and distribution in the distant heliosphere. The team has accomplished the entire set of tasks A-H set forth in the proposal. Namely, the transport modeling framework has been augmented with two populations of pickup ions (PUIs), the boundary conditions for the plasma and interstellar neutral hydrogen were verified against Ulysses and New Horizons PUI and an optimal set of velocity diffusion parameters established. The multi-component fluxes of PUIs were computed and isotropic velocity distributions generated for each cell in the computer simulation that covered the heliosphere from 1.5 AU to the heliopause. The distributions were carefully compared with in situ measurements at 3 AU (Ulysses), 12 AU (New Horizons), and 80-90 AU (Voyager 1 and 2) as well as those inferred from ENA fluxes measured by Cassini and IBEX (Wu et al., 2016). Some examples of modeldata comparison are shown in Figure 1. We have used coupled MHD-plasma and kinetic-neutral code to investigate the likely range of plasma and magnetic field parameters in the local interstellar medium (LISM), based on the assumption that the shape of the IBEX ribbon could be used to determine the orientation of the interstellar magnetic field. While the magnetic field is believed to be

  11. Single neutron pick-up on 104Pd

    International Nuclear Information System (INIS)

    Rodrigues, M.R.D.; Andre, J.P.A.M. de; Borello-Lewin, T.; Horodynski-Matsushigue, L.B.; Duarte, J.L.M.; Rodrigues, C.L.; Ukita, G.M.

    2006-01-01

    Low-lying levels of 103 Pd have been investigated through the (d,t) reaction on 104 Pd, at an incident deuteron energy of 15.0 MeV. Outgoing particles were momentum analyzed by an Enge magnetic spectrograph and detected in nuclear emulsion plates, with an energy resolution of 8 keV. Previous (d,t) work suffered from a much worse resolution than that here achieved. A partial analysis of the data obtained is reported, referring to six out of the fourteen scattering angles for which data were obtained. Angular distributions associated with eight of the thirteen levels seen up to 1.1 MeV of excitation have been compared to DWBA one-neutron pick-up predictions. Both, the attributed excitation energy values and the transferred angular momenta are in excellent agreement with the results of other kind of experiments, as tabulated by the Nuclear Data Sheets. Some peculiar structure characteristics, associated with the yrast 5/2 + , 3/2 + and 7/2 + states found in the Ru chain could be recognized also in 103 Pd, pointing to the possibility of a more global understanding of this transitional mass region. (author)

  12. Pick-up and impact of flexible bodies

    Science.gov (United States)

    Singh, H.; Hanna, J. A.

    2017-09-01

    Picking up, laying down, colliding, rolling, and peeling are partial-contact interactions involving moving discontinuities. We examine the balances of momentum and energy across a moving discontinuity in a string, with allowance for injection or dissipation by singular supplies. We split the energy dissipation according to its invariance properties, discuss analogies with systems of particles and connections with the literature on shocks and phase transition fronts in various bodies, and derive a compatibility relation between supplies of momentum and translation-invariant energy. For a moving contact discontinuity between a string and a smooth rigid plane in the presence of gravity, we find a surprising asymmetry between the processes of picking up and laying down, such that steady-state kinks in geometry and associated jumps in tension are not admissible during pick-up. This prediction is consistent with experimental observations. We briefly discuss related problems including the falling folded chain, peeling of an adhesive tape, and the "chain fountain". Our approach is applicable to the study of impact and locomotion, and to systems such as moored floating structures and some musical instruments that feature vibrating string and cable elements interacting with a surface.

  13. Directing the Branching Growth of Cuprous Oxide by OH- Ions

    Science.gov (United States)

    Chen, Kunfeng; Si, Yunfei; Xue, Dongfeng

    The effect of OH- ions on the branching growth of cuprous oxide microcrystals was systematically studied by a reduction route, where copper-citrate complexes were reduced by glucose under alkaline conditions. Different copper salts including Cu(NO3)2, CuCl2, CuSO4, and Cu(Ac)2 were used in this work. The results indicate that the Cu2O branching growth habit is closely correlated to the concentration of OH- ions, which plays an important role in directing the diffusion-limited branching growth of Cu2O and influencing the reduction power of glucose. A variety of Cu2O branching patterns including 6-pod, 8-pod and 24-pod branches, have been achieved without using template and surfactant. The current method can provide a good platform for studying the growth mechanism of microcrystal branching patterns.

  14. PTOLEMY, a program for heavy-ion direction-reaction calculations

    International Nuclear Information System (INIS)

    Gloeckner, D.H.; Macfarlane, M.H.; Pieper, S.C.

    1976-03-01

    Ptolemy is an IBM/360 program for the computation of nuclear elastic and direct-reaction cross sections. It carries out both optical-model fits to elastic-scattering data at one or more energies, and DWBA calculations for nucleon-transfer reactions. Ptolemy has been specifically designed for heavy-ion calculations. It is fast and does not require large amounts of core. The input is exceptionally flexible and easy to use. This report outlines the types of calculation that Ptolemy can carry out, summarizes the formulas used, and gives a detailed description of its input

  15. Direct observation of the point-defect structure of depleted-zones in ion-irradiated metals

    International Nuclear Information System (INIS)

    Wei, C.

    1978-01-01

    The point-defect structure of individual depleted zones has been studied systematically. Four-pass zone-refined tungsten field-ion microscope (FIM) specimens were irradiated in-situ at 10 K with 30 keV Cr + , Mo + , or W + ions to a total dose of (2 to 10) x 10 12 ion cm -2 and examined by the pulse field-evaporation technique at 10 K. The experimental conditions were such that each depleted zone was created by a single incident-ion. The number of vacant lattice sites within a depleted zone was compared with a modified Kinchin--Pease model. The radial distribution function was determined for each depleted zone; it was found that the vacant lattice sites within the volume of each depleted zone tended to exist in a highly clustered state. It was found that the diameter D of each depleted zone was described by the equation D approximately equal to [y 2 ]/sup 1 / 2 / where [y 2 ]/sup 1 / 2 / is the second moment of the theoretical distribution curve, of the fraction of incident ion energy deposited in atom motion, transverse to the direction of the incident ion-beam. The spatial distribution of self-interstitial atoms (SIAs) in a specimen irradiated with 30 keV Cr + ions and in a specimen irradiated with 18 keV Au + ions, at 10 K, was determined. A low bound to the average range of replacement collision sequences (RCSs) was found to be 175 +- 85 A. A detailed FIM study was also made of the vacancy structure of a (220) platelet created by a single 30 keV W + ion in a platinum-4.0 at. % gold alloy; the specimen was irradiated at 40 K and then isochronally warmed to 100 K. The (220) platelet was found to consist of 31 vacant lattice sites, lying in four (220) planes, and clustered in a disc-shaped region which is approximately 20 A in diameter. It was suggested that prismatic dislocation loops lying on (220) type planes in ion or fast neutron irradiated platinum can form as a result of the direct collapse of (220) type vacancy platelets

  16. Hot magnetospheric O+ and cold ion behavior in magnetopause reconnection: Cluster observations

    Science.gov (United States)

    Wang, S.; Kistler, L. M.; Mouikis, C. G.; Liu, Y.; Genestreti, K. J.

    2014-12-01

    In reconnection, the presence of heavy ions like O+ increases the ion mass density reducing the fluid's Alfvén speed. In addition, it may modify the reconnection structure, which can also change the reconnection rate. However, because O+ ions have a larger Larmor radii than H+ ions at the same velocity, they may not be fully entrained in the reconnection flow and may have kinetic effects other than just increasing the mass density. In this study, for the first time, the ion velocity distribution functions of H+ and O+ from one magnetopause reconnection event with a strong guide field are analyzed to determine in detail the behavior of the different ion populations. We show that the hot magnetospheric O+ ions, along with the hot magnetospheric H+ ions almost fully participate in the reconnection exhaust flows. Finite Larmor radius effects are also apparent and control how far the ions extend on the magnetosheath side. Ion signatures consistent with heating after being picked up in the reconnection exhaust flow are observed in the H+ and O+ distribution functions. The dynamics of the cold magnetospheric ions depends on where they enter the reconnection region. If they enter the reconnection region at the downstream separatrix, they will be taken away by the magnetic field in an adiabatic way as analyzed by Drake et al. (2009a); if they enter close to the diffusion region, they behave as pick-up ions.

  17. XUV-Exposed, Non-Hydrostatic Hydrogen-Rich Upper Atmospheres of Terrestrial Planets. Part II: Hydrogen Coronae and Ion Escape

    Science.gov (United States)

    Lammer, Helmut; Holmström, Mats; Panchenko, Mykhaylo; Odert, Petra; Erkaev, Nikolai V.; Leitzinger, Martin; Khodachenko, Maxim L.; Kulikov, Yuri N.; Güdel, Manuel; Hanslmeier, Arnold

    2013-01-01

    Abstract We studied the interactions between the stellar wind plasma flow of a typical M star, such as GJ 436, and the hydrogen-rich upper atmosphere of an Earth-like planet and a “super-Earth” with a radius of 2 REarth and a mass of 10 MEarth, located within the habitable zone at ∼0.24 AU. We investigated the formation of extended atomic hydrogen coronae under the influences of the stellar XUV flux (soft X-rays and EUV), stellar wind density and velocity, shape of a planetary obstacle (e.g., magnetosphere, ionopause), and the loss of planetary pickup ions on the evolution of hydrogen-dominated upper atmospheres. Stellar XUV fluxes that are 1, 10, 50, and 100 times higher compared to that of the present-day Sun were considered, and the formation of high-energy neutral hydrogen clouds around the planets due to the charge-exchange reaction under various stellar conditions was modeled. Charge-exchange between stellar wind protons with planetary hydrogen atoms, and photoionization, lead to the production of initially cold ions of planetary origin. We found that the ion production rates for the studied planets can vary over a wide range, from ∼1.0×1025 s−1 to ∼5.3×1030 s−1, depending on the stellar wind conditions and the assumed XUV exposure of the upper atmosphere. Our findings indicate that most likely the majority of these planetary ions are picked up by the stellar wind and lost from the planet. Finally, we estimated the long-time nonthermal ion pickup escape for the studied planets and compared them with the thermal escape. According to our estimates, nonthermal escape of picked-up ionized hydrogen atoms over a planet's lifetime within the habitable zone of an M dwarf varies between ∼0.4 Earth ocean equivalent amounts of hydrogen (EOH) to stars—Early atmospheres—Earth-like exoplanets—Energetic neutral atoms—Ion escape—Habitability. Astrobiology 13, 1030–1048. PMID:24283926

  18. The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole.

    Science.gov (United States)

    Rodrigues, G; Becker, R; Hamm, R W; Baskaran, R; Kanjilal, D; Roy, A

    2014-02-01

    The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged (238)U(40+) (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

  19. The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole

    Science.gov (United States)

    Rodrigues, G.; Becker, R.; Hamm, R. W.; Baskaran, R.; Kanjilal, D.; Roy, A.

    2014-02-01

    The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged 238U40+ (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

  20. Ion Diffusion-Directed Assembly Approach to Ultrafast Coating of Graphene Oxide Thick Multilayers.

    Science.gov (United States)

    Zhao, Xiaoli; Gao, Weiwei; Yao, Weiquan; Jiang, Yanqiu; Xu, Zhen; Gao, Chao

    2017-10-24

    The layer-by-layer (LbL) assembly approach has been widely used to fabricate multilayer coatings on substrates with multiple cycles, whereas it is hard to access thick films efficiently. Here, we developed an ion diffusion-directed assembly (IDDA) strategy to rapidly make multilayer thick coatings in one step on arbitrary substrates. To achieve multifunctional coatings, graphene oxide (GO) and metallic ions were selected as the typical building blocks and diffusion director in IDDA, respectively. With diffusion of metallic ions from substrate to negatively charged GO dispersion spontaneously (i.e., from high-concentration region to low-concentration region), GO was assembled onto the substrate sheet-by-sheet via sol-gel transformation. Because metallic ions with size of subnanometers can diffuse directionally and freely in the aqueous dispersion, GO was coated on the substrate efficiently, giving rise to films with desired thickness up to 10 μm per cycle. The IDDA approach shows three main merits: (1) high efficiency with a μm-scale coating rate; (2) controllability over thickness and evenness; and (3) generality for substrates of plastics, metals and ceramics with any shapes and morphologies. With these merits, IDDA strategy was utilized in the efficient fabrication of functional graphene coatings that exhibit outstanding performance as supercapacitors, electromagnetic interference shielding textiles, and anticorrosion coatings. This IDDA approach can be extended to other building blocks including polymers and colloidal nanoparticles, promising for the scalable production and application of multifunctional coatings.

  1. Ion transport membrane module and vessel system with directed internal gas flow

    Science.gov (United States)

    Holmes, Michael Jerome; Ohrn, Theodore R.; Chen, Christopher Ming-Poh

    2010-02-09

    An ion transport membrane system comprising (a) a pressure vessel having an interior, an inlet adapted to introduce gas into the interior of the vessel, an outlet adapted to withdraw gas from the interior of the vessel, and an axis; (b) a plurality of planar ion transport membrane modules disposed in the interior of the pressure vessel and arranged in series, each membrane module comprising mixed metal oxide ceramic material and having an interior region and an exterior region; and (c) one or more gas flow control partitions disposed in the interior of the pressure vessel and adapted to change a direction of gas flow within the vessel.

  2. Preparation of MgB2 superconducting microbridges by focused ion beam direct milling

    Science.gov (United States)

    Zhang, Xuena; Li, Yanli; Xu, Zhuang; Kong, Xiangdong; Han, Li

    2017-01-01

    MgB2 superconducting microbridges were prepared by focused ion beam (FIB) direct milling on MgB2 films. The surface topography of the microbridges were observed using SEM and AFM and the superconductivity was measured in this paper. Lots of cracks and holes were found near the milled area. And the superconducting transition temperature was decreased a lot and the bridges prepared were not superconducting due to ion damage after milled with large dose. Through these works, we explored the effect regular of FIB milling and experimental parameters on the performance of microbridges.

  3. Chemistry of ice: Migration of ions and gases by directional freezing of water

    Directory of Open Access Journals (Sweden)

    Umer Shafique

    2016-09-01

    Full Text Available Redistribution of anions and cations creates an electrical imbalance in ice grown from electrolyte solutions. Movement of acidic and basic ions in cooling solutions can permanently change the pH of frozen and unfrozen parts of the system, largely. The extent of pH change associated with freezing is determined by solute concentration and the extent of cooling. In the present work, redistribution of hydrogen, hydroxyl, carbonate, and bicarbonate ions was studied during directional freezing in batch aqueous systems. Controlled freezing was employed vertically as well as radially in acidic and basic solutions. In each case, the ions substantially migrated along with moving freezing front. Conductometry and pH-metry were employed to monitor the moving ions. Besides, some other experiments were carried out with molecular gases, such as oxygen, carbon dioxide, and chlorine and an azeotropic mixture like water–ethanol. Findings can be used to understand possible changes that can occur in preserving materials by freezing.

  4. An adaptive large neighborhood search heuristic for the pickup and delivery problem with time Windows and scheduled lines

    NARCIS (Netherlands)

    Ghilas, V.; Demir, E.; van Woensel, T.

    2016-01-01

    The Pickup and Delivery Problem with Time Windows and Scheduled Lines (PDPTW-SL) concerns scheduling a set of vehicles to serve freight requests such that a part of the journey can be carried out on a scheduled public transportation line. Due to the complexity of the problem, which is NP-hard, we

  5. The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, G., E-mail: gerosro@gmail.com; Kanjilal, D.; Roy, A. [Inter University Accelerator Centre, Aruna Asaf Ali Marg, New Delhi (India); Becker, R. [Institut fur Angewandte Physik der Universitaet, D-60054 Frankfurt/M (Germany); Hamm, R. W. [R and M Technical Enterprises, Inc., 4725 Arlene Place, Pleasanton, California 94566 (United States); Baskaran, R. [Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamilnadu (India)

    2014-02-15

    The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged {sup 238}U{sup 40+} (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

  6. Micromanipulation and pick-up system for X-Ray diffraction characterization of micrometer-sized single particles

    International Nuclear Information System (INIS)

    Takeichi, Y; Inami, N; Saito, K; Otori, H; Sagayama, R; Kumai, R; Ono, K; Ueno, T

    2014-01-01

    We describe a micromanipulation and pick-up system for preparing a micrometer-sized single particle for X-ray diffraction characterization. Combining a microgripper based on microelectromechanical systems, piezo-motor-driven linear stages, and a gamepad, the system provides precise and intuitive handling of the object. Single-crystal X-ray diffraction measurements of Sm-Fe-N permanent magnet were performed using this system. We also describe a method to distinguish crystallographically homogeneous particles found in powder-form samples.

  7. Theory of nuclear heavy-ion direct transfer reactions

    International Nuclear Information System (INIS)

    Crowley, B.J.B.

    1979-01-01

    We review the distorted-wave approach to direct transfer reactions and draw attention to some of the shortcomings of current theories. We show that a reformulated form of the distorted-wave Born approximation (DWBA) for transfer can lead to important simplifications of the theory, which are valid for nuclear heavy-ion induced reactions at energies > or approx. =MeV/nucleon. In particular, in the semiclassical limit, it leads to a new and simple formula for the transfer t-matrix which includes all the essential physics while offering several important advantages over standard ''full-recoil finite-range'' DWBA. One such advantage is that the new formula is more transparent in that it is amendable to interpretation and analytical manipulation. At high-energy it is shown to reduce to one earlier deduced using eikonal-DWBA. The conditions for the validity of the new theory are discussed in detail. They are shown to be generally well satisfied for small-mass transfer between heavy-ions at energies at or above those particularly favour transfer (> or approx. =10 MeV/nucleon for transfer of valence nucleons). The restriction to small mass is not due to any recoil approximation; in fact, it is only a necessary restriction at certain energies. The theory treats recoil exactly. Consideration of the optimum dynamical conditions for transfer leads to a set of matching conditions. The presence of hitherto neglected absorption, arising from dynamical effects of poor matching, it suggested and qualitatively discussed. Condition under which such absorption may be neglected are derived. Results of numerical calculations are presented showing that the theory is capable of good agreement with standard full-recoil finite-range DWBA, and that it is capable of giving at least as good an account of experimental data for nucleon-transfer between heavy-ions at energies approx.10 MeV/nucleon

  8. Musical instrument recordings made with a fiber Fabry-Perot cavity: photonic guitar pickup.

    Science.gov (United States)

    Ballard, Nicholas; Paz-Soldan, Daniel; Kung, Peter; Loock, Hans-Peter

    2010-04-10

    A 1 cm long, low-finesse fiber-optic cavity was used as a transducer for the vibrations of the soundboard of an acoustic guitar and of a violin. The reflected light is detected and then amplified and recorded using conventional audio instrumentation. The fiber-optic pickup is found to have a high response range in both amplitude (up to 100 microm displacement) and audio frequency (DC to 20 kHz) and good linearity up to a displacement of 225 microm. The audio noise is found to arise from the fiber-optic cables and, to a lesser extent, from the laser and laser driver.

  9. Coulomb thermal properties and stability of the Io plasma torus

    Science.gov (United States)

    Barbosa, D. D.; Coroniti, F. V.; Eviatar, A.

    1983-01-01

    Coulomb collisional energy exchange rates are computed for a model of the Io plasma torus consisting of newly created pickup ions, a background of thermally degraded intermediary ions, and a population of cooler electrons. The electrons are collisionally heated by both the pickup ions and background ions and are cooled by electron impact excitation of plasma ions which radiate in the EUV. It is found that a relative concentration of S III pickup ions forbidden S III/electrons = 0.1 with a temperature of 340 eV can deliver energy to the electrons at a rate of 3 x 10 to the -13th erg/cu cm per sec, sufficient to power the EUV emissions in the Io torus. The model predicts a background ion temperature Ti of about 53 eV and an electron temperature Te of about 5.5 eV on the basis of steady-state energy balance relations at Coulomb rates. The model also predicts electron temperature fluctuations at the 30 percent level on a time scale of less than 11 hours, consistent with recent observations of this phenomenon.

  10. Nonlinear MHD waves and discontinuities in the Martian magnetosheath. Observations and 2D bi-ion MHD simulations

    Science.gov (United States)

    Sauer, K.; Dubinin, E.; Baumgärtel, K.

    1998-09-01

    The characteristic scale of the Martian magnetosheath is less than the pick-up gyroradius of oxygen ions. This leads to admissible differential motion of protons and heavies and a strong coupling between both ion fluids. 2D bi-ion MHD simulations reveal many new interesting features in such Large Larmour Radius systems. The formation of an ion-composition boundary, which separates both plasmas, and structuring of the transition from proton dominated plasma of the solar wind origin to massive planetary plasma are the main features of the interaction. A comprehensive multi-instrument study of Martian plasma environment and the comparison with theoretical modelling initiated in the framework of the Visiting Science Programme of the International Space Science Institute (ISSI) in Bern (Switzerland) gives confirmation that Mars interacts with the solar wind like a comet which has a outgassing rate near to that of Grigg-Skjellerup. The results may also be relevant for small bodies which are surrounded by a neutral gas atmosphere (icy moons, asteroids, Mercury).

  11. Damage accumulation in nitrogen implanted 6H-SiC: Dependence on the direction of ion incidence and on the ion fluence

    International Nuclear Information System (INIS)

    Zolnai, Z.; Ster, A.; Khanh, N. Q.; Battistig, G.; Lohner, T.; Gyulai, J.; Kotai, E.; Posselt, M.

    2007-01-01

    The influence of crystallographic orientation and ion fluence on the shape of damage distributions induced by 500 keV N + implantation at room temperature into 6H-SiC is investigated. The irradiation was performed at different tilt angles between 0 degree sign and 4 degree sign with respect to the crystallographic axis in order to consider the whole range of beam alignment from channeling to random conditions. The applied implantation fluence range was 2.5x10 14 -3x10 15 cm -2 . A special analytical method, 3.55 MeV 4 He + ion backscattering analysis in combination with channeling technique (BS/C), was employed to measure the disorder accumulation simultaneously in the Si and C sublattices of SiC with good depth resolution. For correct energy to depth conversion in the BS/C spectra, the average electronic energy loss per analyzing He ion for the axial channeling direction was determined. It was found that the tilt angle of nitrogen implantation has strong influence on the shape of the induced disorder profiles. Significantly lower disorder was found for channeling than for random irradiation. Computer simulation of the measured BS/C spectra showed the presence of a simple defect structure in weakly damaged samples and suggested the formation of a complex disorder state for higher disorder levels. Full-cascade atomistic computer simulation of the ion implantation process was performed to explain the differences in disorder accumulation on the Si and C sublattices. The damage buildup mechanism was interpreted with the direct-impact, defect-stimulated amorphization model in order to understand damage formation and to describe the composition of structural disorder versus the ion fluence and the implantation tilt angle

  12. Boundary element analysis of the directional sensitivity of the concentric EMG electrode.

    Science.gov (United States)

    Henneberg, K A; Plonsey, R

    1993-07-01

    Assessment of the motor unit architecture based on concentric electrode motor unit potentials requires a thorough understanding of the recording characteristics of the concentric EMG electrode. Previous simulation studies have attempted to include the effect of EMG electrodes on the recorded waveforms by uniformly averaging the tissue potential at the coordinates of one- or two-dimensional electrode models. By employing the boundary element method, this paper improves earlier models of the concentric EMG electrode by including an accurate geometric representation of the electrode, as well as the mutual electrical influence between the electrode surfaces. A three-dimensional sensitivity function is defined from which information about the preferential direction of sensitivity, blind spots, phase changes, rate of attenuation, and range of pick-up radius can be derived. The study focuses on the intrinsic features linked to the geometry of the electrode. The results show that the cannula perturbs the potential distribution significantly. The core and the cannula electrodes measure potentials of the same order of magnitude in all of the pick-up range, except adjacent to the central wire, where the latter dominates the sensitivity function. The preferential directions of sensitivity are determined by the amount of geometric offset between the individual sensitivity functions of the core and the cannula. The sensitivity function also reveals a complicated pattern of phase changes in the pick-up range. Potentials from fibers located behind the tip or along the cannula are recorded with reversed polarity compared to those located in front of the tip. Rotation of the electrode about its axis was found to alter the duration, the peak-to-peak amplitude, and the rise time of waveforms recorded from a moving dipole.

  13. XUV-exposed, non-hydrostatic hydrogen-rich upper atmospheres of terrestrial planets. Part II: hydrogen coronae and ion escape.

    Science.gov (United States)

    Kislyakova, Kristina G; Lammer, Helmut; Holmström, Mats; Panchenko, Mykhaylo; Odert, Petra; Erkaev, Nikolai V; Leitzinger, Martin; Khodachenko, Maxim L; Kulikov, Yuri N; Güdel, Manuel; Hanslmeier, Arnold

    2013-11-01

    We studied the interactions between the stellar wind plasma flow of a typical M star, such as GJ 436, and the hydrogen-rich upper atmosphere of an Earth-like planet and a "super-Earth" with a radius of 2 R(Earth) and a mass of 10 M(Earth), located within the habitable zone at ∼0.24 AU. We investigated the formation of extended atomic hydrogen coronae under the influences of the stellar XUV flux (soft X-rays and EUV), stellar wind density and velocity, shape of a planetary obstacle (e.g., magnetosphere, ionopause), and the loss of planetary pickup ions on the evolution of hydrogen-dominated upper atmospheres. Stellar XUV fluxes that are 1, 10, 50, and 100 times higher compared to that of the present-day Sun were considered, and the formation of high-energy neutral hydrogen clouds around the planets due to the charge-exchange reaction under various stellar conditions was modeled. Charge-exchange between stellar wind protons with planetary hydrogen atoms, and photoionization, lead to the production of initially cold ions of planetary origin. We found that the ion production rates for the studied planets can vary over a wide range, from ∼1.0×10²⁵ s⁻¹ to ∼5.3×10³⁰ s⁻¹, depending on the stellar wind conditions and the assumed XUV exposure of the upper atmosphere. Our findings indicate that most likely the majority of these planetary ions are picked up by the stellar wind and lost from the planet. Finally, we estimated the long-time nonthermal ion pickup escape for the studied planets and compared them with the thermal escape. According to our estimates, nonthermal escape of picked-up ionized hydrogen atoms over a planet's lifetime within the habitable zone of an M dwarf varies between ∼0.4 Earth ocean equivalent amounts of hydrogen (EO(H)) to <3 EO(H) and usually is several times smaller in comparison to the thermal atmospheric escape rates.

  14. Direct-indirect mixed implosion mode in heavy ion inertial fusion

    International Nuclear Information System (INIS)

    Kawata, S.; Miyazawa, K.; Kikuchi, T.; Someya, T.

    2007-01-01

    In order to realize an effective implosion, beam illumination non-uniformity on a fuel target must be suppressed less than a few percent. In this study, a direct-indirect mixture implosion mode is proposed and discussed in heavy ion beam (HIB) inertial confinement fusion (HIF) in order to release sufficient fusion energy in a robust manner. On the other hand, the HIB illumination non-uniformity depends strongly on a target displacement dz from the center of a fusion reactor chamber. In a direct-driven implosion mode, dz of ∼20 μm was tolerable, and in an indirect-implosion mode, dz of ∼100 μm was allowable. In the direct-indirect mixture mode target, a low-density foam layer is inserted, and the radiation energy is confined in the foam layer. In the foam layer, the radiation transport is expected to smooth the HIB illumination non-uniformity in the lateral direction. Two-dimensional implosion simulations are performed, and show that the HIB illumination non-uniformity is well smoothed in the direct-indirect mixture target. Our simulation results present that a large pellet displacement of approximately a few hundred microns is allowed in order to obtain a sufficient fusion energy output in HIF

  15. A direct plasma injection system into an RFQ for clean and safe ion implantation

    International Nuclear Information System (INIS)

    Takeuchi, T.; Katayama, T.; Okamura, M.; Yano, K.; Sakumi, A.; Hattori, T.; Hayashizaki, N.; Jameson, R.A.

    2002-01-01

    A new injection system, direct plasma injection system, was tested and its principle was proved successfully. We found that one of advantages of this injection system was efficient consumption of source materials. Large portions of induced ions can be injected into a first stage accelerator. This feature is quite useful for ion implantation applications, because toxic exhaust gas can be eliminated. In order to utilize this system for industrial application, the feasibility of a boron injection scheme using a Nd:YAG laser system was investigated

  16. A Direct Simulation Monte Carlo Model Of Thermal Escape From Titan

    Science.gov (United States)

    Johnson, Robert E.; Tucker, O. J.

    2008-09-01

    Recent analysis of density profiles vs. altitude from the Ion Neutral Mass Spectrometer (INMS) on Cassini (Waite et al. 2005) suggest Titan could have loss a significant amount of atmosphere in 4 Gyr at present escape rates (e.g., Johnson 2008). Strobel 2008 applied a slow hydrodynamic escape model to Titan's atmosphere using solar heating below the exobase to drive upward thermal conduction and power escape. However, near the exobase continuum models become problematic as a result of the increasing rarefaction in the atmosphere. The microscopic nature of DSMC is directly suitable to model atmosphere flow in nominal exobase region (e.g., Michael et. al. 2005). Our Preliminary DSMC models have shown no evidence for slow hydrodynamic escape of N2 and CH4 from Titan's atmosphere using boundary conditions normalized to the atmospheric properties in Strobel (2008). In this paper we use a 1D radial Direct Simulation Monte Carlo (DSMC) model of heating in Titan's upper atmosphere to estimate the escape rate as a function of the Jean's parameter. In this way we can test under what conditions the suggested deviations from Jeans escape would occur. In addition, we will be able to extract the necessary energy deposition to power the heavy molecule loss rates suggested in recent models (Strobel 2008; Yelle et. al. 2008). Michael, M. Johnson, R.E. 2005 Energy Deposition of pickup ions and heating of Titan's atmosphere. Planat. Sp. Sci. 53, 1510-1514 Johnson, R.E., "Sputtering and Heating of Titan's Upper Atmosphere", Proc Royal Soc. (London) (2008) Strobel, D.F. 2008 Titan's hydrodynamically escaping atmosphere. Icarus 193, 588-594 Yelle, R.V., J. Cui and I. C.F. Muller-Wodarg 2008 Methane Escape from Titan's Atmosphere. J. Geophys. Res in press Waite, J.H., Jr., Niemann, H.B., Yelle, R.V. et al. 2005 Ion Neutral Mass Spectrometer Results from the First Flyby of Titan. Science 308, 982-986

  17. Integration of agglutination assay for protein detection in microfluidic disc using Blu-ray optical pickup unit and optical fluid scanning

    DEFF Research Database (Denmark)

    Uddin, Rokon; Burger, Robert; Donolato, Marco

    2015-01-01

    We present a novel strategy for thrombin detection by combining a magnetic bead based agglutination assay and low-cost microfluidic disc. The detection method is based on an optomagnetic readout system implemented using a Blu-ray optical pickup unit (OPU) as main optoelectronic component. The ass...

  18. Study of mode-converted and directly-excited ion Bernstein waves by CO2 laser scattering in Alcator C

    International Nuclear Information System (INIS)

    Takase, Y.; Fiore, C.L.; McDermott, F.S.; Moody, J.D.; Porkolab, M.; Shepard, T.; Squire, J.

    1987-01-01

    Mode-converted and directly excited ion Bernstein waves (IBW) were studied using CO 2 laser scattering in the Alcator C tokamak. During the ICRF fast wave heating experiments, mode-converted IBW was observed on the high-field side of the resonance in both second harmonic and minority heating regimes. By comparing the relative scattered powers from the two antennas separated by 180 0 toroidally, an increased toroidal wave damping with increasing density was inferred. In the IBW heating experiments, optimum direct excitation is obtained when an ion-cyclotron harmonic layer is located just behind the antenna. Wave absorption at the ω = 3Ω/sub D/ = 1.5Ω/sub H/ layer was directly observed. Edge ion heating was inferred from the IBW dispersion when this absorption layer was located in the plasma periphery, which may be responsible for the observed improvement in particle confinement

  19. Rapidly patterning micro/nano devices by directly assembling ions and nanomaterials

    OpenAIRE

    Na Liu; Feifei Wang; Lianqing Liu; Haibo Yu; Shaorong Xie; Jun Wang; Yuechao Wang; Gwo-Bin Lee; Wen J. Li

    2016-01-01

    The synthesis and assembly of components are key steps in micro/nano device manufacturing. In this article, we report an optically controlled assembly method that can rapidly pattern micro/nano devices by directly assembling ions and nanomaterials without expensive physical masks and complex etching processes. Utilizing this controllable process, different types of device components (e.g., metallic and semiconductor) can be fabricated and assembled in 10?30?seconds, which is far more rapid an...

  20. Direct acceleration of ions to low and medium energies by a crossed-laser-beam configuration

    Directory of Open Access Journals (Sweden)

    Yousef I. Salamin

    2011-07-01

    Full Text Available Calculations show that 10 keV helium and carbon ions, injected midway between two identical 1 TW-power crossed laser beams of radial polarization, can be accelerated in vacuum to energies of utility in ion lithography. As examples, identical laser beams, crossed at 10° and focused to waist radii of 7.42  μm, accelerate He^{2+} and C^{6+} ions to average kinetic energies near 75 and 165 keV over distances averaging less than 7 and 6 mm, respectively. The spread in kinetic energy in both cases is less than 1% and the particle average angular deflection is less than 7 mrad. More energy-demanding industrial applications require higher-power laser beams for their direct ion laser acceleration.

  1. Titan's plasma environment: 3D hybrid simulation and comparison with observations

    Science.gov (United States)

    Lipatov, A. S.; Sittler, E. C.; Hartle, R. E.

    2007-12-01

    A multiscale combined (fluid--kinetic) numerical method allows us to use more realistic plasma models at Titan. This method takes into account charge-exchange and photoionization processes. We study the Titan's plasma environment in case of high, intermediate and low exosphere density in Chamberlain models. The background ions H+, O+ and pickup ions H2+, CH4+ and N2+ are described in a kinetic approximation, where the electrons are approximated as a fluid. We also include an immobile ionosphere at the height 1300km. In this report we consider the multiscale spatial structure for plasma and electromagnetic field, and the velocity distribution of ions that results from the coupling between background ions and pickup ions. Special attention will be paid for the comparisons our numerical results with Voyager and Cassini observations (see e.g. [Sittler, Hartle, et al., 2005; Hartle, Sittler et al., 2006]). We shall estimate of mass loading rate for Ta, energy input to upper atmosphere from ambient +pickup ions, and the T9 encounter with two crossings. \

  2. Single neutron pick-up on {sup 104}Pd

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, M.R.D.; Andre, J.P.A.M. de; Borello-Lewin, T.; Horodynski-Matsushigue, L.B.; Duarte, J.L.M.; Rodrigues, C.L. [Universidade de Sao Paulo, SP (Brazil). Inst. de Fisica; Ukita, G.M. [Universidade de Santo Amaro, SP (Brazil). Faculdade de Psicologia

    2006-12-15

    Low-lying levels of {sup 103}Pd have been investigated through the (d,t) reaction on {sup 104}Pd, at an incident deuteron energy of 15.0 MeV. Outgoing particles were momentum analyzed by an Enge magnetic spectrograph and detected in nuclear emulsion plates, with an energy resolution of 8 keV. Previous (d,t) work suffered from a much worse resolution than that here achieved. A partial analysis of the data obtained is reported, referring to six out of the fourteen scattering angles for which data were obtained. Angular distributions associated with eight of the thirteen levels seen up to 1.1 MeV of excitation have been compared to DWBA one-neutron pick-up predictions. Both, the attributed excitation energy values and the transferred angular momenta are in excellent agreement with the results of other kind of experiments, as tabulated by the Nuclear Data Sheets. Some peculiar structure characteristics, associated with the yrast 5/2{sup +}, 3/2{sup +} and 7/2{sup +} states found in the Ru chain could be recognized also in {sup 103}Pd, pointing to the possibility of a more global understanding of this transitional mass region. (author)

  3. Nucleation and growth of defects in heavy-ion and electron-bombarded metals. Final report for the period ending February 29, 1980

    International Nuclear Information System (INIS)

    Kulcinski, G.L.

    1983-04-01

    He preinjection was found to be essential in nucleating voids in high-purity Al. Interstitial pickup in high-purity V was found to be important even under good vacuum (10 - 6 to 10 - 7 torr). Voids were found to form in V down to 200 0 C. A model was tested against rdiation disordering/ordering in Cu 3 Au. Disordering in CuPd was studied. A small negative heavy ion source (SNICS) was developed for the tandem accelerator

  4. Dispersion Theory of Direct Nuclear Reactions

    Energy Technology Data Exchange (ETDEWEB)

    Shapiro, I. S. [Institute Of Theoretical And Experimental Physics, Moscow, USSR (Russian Federation)

    1963-01-15

    reasons for the agreement if it is not accidental. In short, the theory behaves like an unpredictable person. A major success in the application of perturbation theory to direct processes in the Butler theory of deuteron stripping ((d, p), (d, n)) and pick-up ((p, d), (n, d)). The Butler theory satisfactorily predicts the position of the first maximum (by the increase of the angle) in the angular distribution of reaction products as a function of the orbital momentum of the nucleon captured by the nucleus (stripping reaction) or picked up by an incident particle (pick- up reaction). This result permitted the use of stripping and pick-up reactions in nuclear spectroscopy. At the same time this led to the problem of understanding the true meaning of the Butler approximation. This problem was also essential because the Butler theory inadequately describes several other features of the stripping and pick-up reactions (such as the change of angular distribution with the energy of incident particles, the relation of intensities at the maxima of angular distributions, absolute values of. cross-sections and, sometimes, the relative probabilities for the excitation of different states of residual nuclei). A new method in direct process theory was offered not so long ago (in 1961). The method is based on fairly general properties of the reaction amplitudes and is free from the un-justified assumptions, of the form er theory, in particular the application of perturbation theory. This method makes it possible to obtain several new results and obtain a uniform description cf a great variety of processes (such as direct reactions of the conventional type at low and medium energies, the transfer of nucleons in the bombardment of nuclei by multi-charged ions and the processes of fragmentation at high energies). At the same time the new approach explains, with surprising simplicity, the causes of the form erly enigmatic success of the Butler theory and indicates the limits of its

  5. Dispersion Theory of Direct Nuclear Reactions

    International Nuclear Information System (INIS)

    Shapiro, I.S.

    1963-01-01

    reasons for the agreement if it is not accidental. In short, the theory behaves like an unpredictable person. A major success in the application of perturbation theory to direct processes in the Butler theory of deuteron stripping ((d, p), (d, n)) and pick-up ((p, d), (n, d)). The Butler theory satisfactorily predicts the position of the first maximum (by the increase of the angle) in the angular distribution of reaction products as a function of the orbital momentum of the nucleon captured by the nucleus (stripping reaction) or picked up by an incident particle (pick- up reaction). This result permitted the use of stripping and pick-up reactions in nuclear spectroscopy. At the same time this led to the problem of understanding the true meaning of the Butler approximation. This problem was also essential because the Butler theory inadequately describes several other features of the stripping and pick-up reactions (such as the change of angular distribution with the energy of incident particles, the relation of intensities at the maxima of angular distributions, absolute values of. cross-sections and, sometimes, the relative probabilities for the excitation of different states of residual nuclei). A new method in direct process theory was offered not so long ago (in 1961). The method is based on fairly general properties of the reaction amplitudes and is free from the un-justified assumptions, of the form er theory, in particular the application of perturbation theory. This method makes it possible to obtain several new results and obtain a uniform description cf a great variety of processes (such as direct reactions of the conventional type at low and medium energies, the transfer of nucleons in the bombardment of nuclei by multi-charged ions and the processes of fragmentation at high energies). At the same time the new approach explains, with surprising simplicity, the causes of the form erly enigmatic success of the Butler theory and indicates the limits of its

  6. Soft ionization of saturated hydrocarbons, alcohols and nonpolar compounds by negative-ion direct analysis in real-time mass spectrometry.

    Science.gov (United States)

    Cody, Robert B; Dane, A John

    2013-03-01

    Large polarizable n-alkanes (approximately C18 and larger), alcohols, and other nonpolar compounds can be detected as negative ions when sample solutions are injected directly into the sampling orifice of the atmospheric pressure interface of the time-of-flight mass spectrometer with the direct analysis in real time (DART) ion source operating in negative-ion mode. The mass spectra are dominated by peaks corresponding to [M + O2]‾(•). No fragmentation is observed, making this a very soft ionization technique for samples that are otherwise difficult to analyze by DART. Detection limits for cholesterol were determined to be in the low nanogram range.

  7. Directly coupled YBCO dc SQUID magnetometers

    International Nuclear Information System (INIS)

    Petersen, P.R.E.; Shen, Y.Q.; Holst, T.; Larsen, B.H.; Sager, M.P.; Bindslev Hansen, J.

    1999-01-01

    YBa 2 Cu 3 O 7- x magnetometers have been made on 10mmx10mm MgO substrates by directly coupling the magnetometer pick-up loop to a dc SQUID with narrow strip lines. The dc SQUIDs were made with YBa 2 Cu 3 O 7-x step-edge Josephson junctions. The layout of the magnetometer pick-up loop was chosen as a compromise between maximizing the loop effective area and minimizing the loop inductance. The SQUID was designed to have L S ∼100 pH in order to obtain β L =2I 0 L S /Φ 0 approx.= 1 with the single-junction critical current I 0 ∼10 μA. We have made magnetometers with white noise levels down to 55 fT Hz -1/2 and a 1/f knee at 1 Hz (ac biased). Noise measurements were made on a field-cooled magnetometer. The noise measured at 1 Hz when cooled in 'zero field' was 175 fT Hz -1/2 . When cooled in magnetic fields of B = 50 μT and B = 100 μT we measured the noise at 1 Hz to be 430 fT Hz -1 2 and 1.3 pT Hz -1/2 , respectively. (author)

  8. Direct observation and theory of trajectory-dependent electronic energy losses in medium-energy ion scattering.

    Science.gov (United States)

    Hentz, A; Parkinson, G S; Quinn, P D; Muñoz-Márquez, M A; Woodruff, D P; Grande, P L; Schiwietz, G; Bailey, P; Noakes, T C Q

    2009-03-06

    The energy spectrum associated with scattering of 100 keV H+ ions from the outermost few atomic layers of Cu(111) in different scattering geometries provides direct evidence of trajectory-dependent electronic energy loss. Theoretical simulations, combining standard Monte Carlo calculations of the elastic scattering trajectories with coupled-channel calculations to describe inner-shell ionization and excitation as a function of impact parameter, reproduce the effects well and provide a means for far more complete analysis of medium-energy ion scattering data.

  9. Controlling trapping potentials and stray electric fields in a microfabricated ion trap through design and compensation

    International Nuclear Information System (INIS)

    Charles Doret, S; Amini, Jason M; Wright, Kenneth; Volin, Curtis; Killian, Tyler; Ozakin, Arkadas; Denison, Douglas; Hayden, Harley; Pai, C-S; Slusher, Richart E; Harter, Alexa W

    2012-01-01

    Recent advances in quantum information processing with trapped ions have demonstrated the need for new ion trap architectures capable of holding and manipulating chains of many (>10) ions. Here we present the design and detailed characterization of a new linear trap, microfabricated with scalable complementary metal-oxide-semiconductor (CMOS) techniques, that is well-suited to this challenge. Forty-four individually controlled dc electrodes provide the many degrees of freedom required to construct anharmonic potential wells, shuttle ions, merge and split ion chains, precisely tune secular mode frequencies, and adjust the orientation of trap axes. Microfabricated capacitors on dc electrodes suppress radio-frequency pickup and excess micromotion, while a top-level ground layer simplifies modeling of electric fields and protects trap structures underneath. A localized aperture in the substrate provides access to the trapping region from an oven below, permitting deterministic loading of particular isotopic/elemental sequences via species-selective photoionization. The shapes of the aperture and radio-frequency electrodes are optimized to minimize perturbation of the trapping pseudopotential. Laboratory experiments verify simulated potentials and characterize trapping lifetimes, stray electric fields, and ion heating rates, while measurement and cancellation of spatially-varying stray electric fields permits the formation of nearly-equally spaced ion chains. (paper)

  10. Direct determination of a radiation-damage profile with atomic resolution in ion-irradiated platinum. MSC report No. 5030

    International Nuclear Information System (INIS)

    Pramanik, D.; Seidman, D.N.

    1983-05-01

    The field-ion microscope (FIM) technique has been employed to determine directly a radiation damage profile, with atomic resolution, in a platinum specimen which had been irradiated at 80 0 K with 20-keV Kr + ions to a fluence of 5 x 10 12 cm - 2 . It is shown that the microscopic spatial-vacancy distribution (radiation-damage profile) is directly related to the elastically-deposited-energy profile. The experimentally constructed radiation-damage profile is compared with a theoretical damage profile - calculated employing the TRIM Monte Carlo code - and excellent agreement is obtained between the two, thus demonstrating that it is possible to go directly from a microscopic spatial distribution of vacancies to a continuous radiation-damage profile

  11. Non-Uniformity of Ion Implantation in Direct-Current Plasma Immersion Ion Implantation

    International Nuclear Information System (INIS)

    Cheng-Sen, Liu; Yu-Jia, Fan; Nan, Zhang; Li, Guan; Yuan, Yao; De-Zhen, Wang

    2010-01-01

    A particle-in-cell simulation is developed to study dc plasma immersion ion implantation. Particular attention is paid to the influence of the voltage applied to the target on the ion path, and the ion flux distribution on the target surface. It is found that the potential near the aperture within the plasma region is not the plasma potential, and is impacted by the voltage applied to the implanted target. A curved equipotential contour expands into the plasma region through the aperture and the extent of the expansion depends on the voltage. Ions accelerated by the electric field in the sheath form a beam shape and a flux distribution on the target surface, which are strongly dependent on the applied voltage. The results of the simulations demonstrate the formation mechanism of the grid-shadow effect, which is in agreement with the result observed experimentally. (physics of gases, plasmas, and electric discharges)

  12. Majority ion heating near the ion-ion hybrid layer in tokamaks

    International Nuclear Information System (INIS)

    Phillips, C.K.; Hosea, J.C.; Ignat, D.; Majeski, R.; Rogers, J.H.; Schilling, G.; Wilson, J.R.

    1995-08-01

    Efficient direct majority ion heating in a deuterium-tritium (D-T) reactor-grade plasma via absorption of fast magnetosonic waves in the ion cyclotron range of frequencies (ICRF) is discussed. Majority ion heating results from resonance overlap between the cyclotron layers and the D-T ion-ion hybrid layer in hot, dense plasmas for fast waves launched with high parallel wavenumbers. Analytic and numerical models are used to explore the regime in ITER plasmas

  13. In-situ, real-time, studies of film growth processes using ion scattering and direct recoil spectroscopy techniques.

    Energy Technology Data Exchange (ETDEWEB)

    Smentkowski, V. S.

    1999-04-22

    Time-of-flight ion scattering and recoil spectroscopy (TOF-ISARS) enables the characterization of the composition and structure of surfaces with 1-2 monolayer specificity. It will be shown that surface analysis is possible at ambient pressures greater than 3 mTorr using TOF-ISARS techniques; allowing for real-time, in situ studies of film growth processes. TOF-ISARS comprises three analytical techniques: ion scattering spectroscopy (ISS), which detects the backscattered primary ion beam; direct recoil spectroscopy (DRS), which detects the surface species recoiled into the forward scattering direction; and mass spectroscopy of recoiled ions (MSRI), which is 3 variant of DRS capable of isotopic resolution for all surface species--including H and He. The advantages and limitations of each of these techniques will be discussed. The use of the three TOF-ISARS methods for real-time, in situ film growth studies at high ambient pressures will be illustrated. It will be shown that MSRI analysis is possible during sputter deposition. It will be also be demonstrated that the analyzer used for MSRI can also be used for time of flight secondary ion mass spectroscopy (TOF-SIMS) under high vacuum conditions. The use of a single analyzer to perform the complimentary surface analytical techniques of MSRI and SIMS is unique. The dwd functionality of the MSRI analyzer provides surface information not obtained when either MSRI or SIMS is used independently.

  14. Ion pair reinforced semi-interpenetrating polymer network for direct methanol fuel cell applications.

    Science.gov (United States)

    Fang, Chunliu; Julius, David; Tay, Siok Wei; Hong, Liang; Lee, Jim Yang

    2012-06-07

    This paper describes the synthesis of ion-pair-reinforced semi-interpenetrating polymer networks (SIPNs) as proton exchange membranes (PEMs) for the direct methanol fuel cells (DMFCs). Specifically, sulfonated poly(2,6-dimethyl-1,4-phenylene oxide) (SPPO), a linear polymer proton source, was immobilized in a brominated PPO (BPPO) network covalently cross-linked by ethylenediamine (EDA). The immobilization of SPPO in the SIPN network was accomplished not only by the usual means of mechanical interlocking but also by ion pair formation between the sulfonic acid groups of SPPO and the amine moieties formed during the cross-linking reaction of BPPO with EDA. Through the ion pair interactions, the immobilization of SPPO polymer in the BPPO network was made more effective, resulting in a greater uniformity of sulfonic acid cluster distribution in the membrane. The hydrophilic amine-containing cross-links also compensated for some of the decrease in proton conductivity caused by ion pair formation. The SIPN membranes prepared as such showed good proton conductivity, low methanol permeability, good mechanical properties, and dimensional stability. Consequently, the PPO based SIPN membranes were able to deliver a higher maximum power density than Nafion, demonstrating the potential of the SIPN structure for PEM designs.

  15. Direct observation of cascade defect formation at low temperatures in ion-irradiated metals

    International Nuclear Information System (INIS)

    Muroga, T.; Hirooka, K.; Ishino, S.

    1984-01-01

    Direct transmission electron microscopy observations of cascade defect formation have been carried out in gold, Type 316 stainless steel, and aluminum irradiated by Al + , Ar - , and Xe + ions with energies between 80 and 400 keV. By utilizing a link of an ion accelerator to an electron microscope, in situ observations at low temperature (-150 0 C) have become possible. In gold, subcascade structures are clearly observed in all cases. Obvious dependence on projectile mass and energy is observed for cascade structure and vacancy clustering efficiency in gold and for defect visibility in aluminum and Type 316 stainless steel. A computer simulation calculation using MARLOWE shows subcascade distributions a little smaller in size and larger in number than the present observation

  16. An experimental study of odd mass promethium isotopes using proton stripping and pickup reactions

    International Nuclear Information System (INIS)

    Straume, O.

    1979-11-01

    Odd Pm isotopes have been studied by one proton pick-up and stripping reactions. Spin assignment and spectroscopic factors have been obtained for a number of energy levels. In the stripping reactions, the relative cross-sections have been measured with an unusually high precision by the use of a target of natural neodymium. The spectroscopic strengths have been extracted using standard distorted wave methods. The nuclear structures of these promethium isotopes fall into three categories. The spherical approach seems valid for 143 Pm and 145 Pm and the deformed regime covers 151 Pm and 153 Pm, while 147 Pm and 149 Pm remain as transitional nuclei. (Auth.)

  17. Investigation of mixed ion fields in the forward direction for 220.5 MeV/u helium ion beams: comparison between water and PMMA targets

    Science.gov (United States)

    Aricò, G.; Gehrke, T.; Jakubek, J.; Gallas, R.; Berke, S.; Jäkel, O.; Mairani, A.; Ferrari, A.; Martišíková, M.

    2017-10-01

    Currently there is a rising interest in helium ion beams for radiotherapy. For benchmarking of the physical beam models used in treatment planning, there is a need for experimental data on the composition and spatial distribution of mixed ion fields. Of particular interest are the attenuation of the primary helium ion fluence and the build-up of secondary hydrogen ions due to nuclear interactions. The aim of this work was to provide such data with an enhanced precision. Moreover, the validity and limits of the mixed ion field equivalence between water and PMMA targets were investigated. Experiments with a 220.5 MeV/u helium ion pencil beam were performed at the Heidelberg Ion-Beam Therapy Center in Germany. The compact detection system used for ion tracking and identification was solely based on Timepix position-sensitive semiconductor detectors. In comparison to standard techniques, this system is two orders of magnitude smaller, and provides higher precision and flexibility. The numbers of outgoing helium and hydrogen ions per primary helium ion as well as the lateral particle distributions were quantitatively investigated in the forward direction behind water and PMMA targets with 5.2-18 cm water equivalent thickness (WET). Comparing water and PMMA targets with the same WET, we found that significant differences in the amount of outgoing helium and hydrogen ions and in the lateral particle distributions arise for target thicknesses above 10 cm WET. The experimental results concerning hydrogen ions emerging from the targets were reproduced reasonably well by Monte Carlo simulations using the FLUKA code. Concerning the amount of outgoing helium ions, significant differences of 3-15% were found between experiments and simulations. We conclude that if PMMA is used in place of water in dosimetry, differences in the dose distributions could arise close to the edges of the field, in particular for deep seated targets. The results presented in this publication are

  18. Behaviour of direct and delayed fast ion losses during NBI on TJ-II

    International Nuclear Information System (INIS)

    Guasp, J.; Liniers; M.

    1995-09-01

    The dependence with density and beam energy of the different kind of fast ion losses, direct and delayed, during tangential balanced NBI injection in TJ-II helical axis stellerator has been analysed. Direct losses increase with energy and a strong difference between the two injection directions appears, are produced by passing particles that loss confinement in a dew mu,sec and the influence of birth profiles produces an increase with density. Delayed losses are very well separated in time from direct ones, are produced by particles experimenting pitch angle scattering an,d, most o them, correspond to trapped particles. Are much less important than the direct ones (about 1/3), decrease slowly with energy and, with CX, increase with density (an effect of initial profile). The absorption is rather independent of energy with low values at low density in reason of high shine trough and CX losses, but reovers quickly with the density increase

  19. Behaviour of direct and delayed fast ion losses during NBI on TJ-II

    International Nuclear Information System (INIS)

    Guasp, J.; Liniers, M.

    1995-01-01

    The dependence with density and beam energy of the different kind of fast ion losses, direct and delayed, during tangential balanced NBI injection in TJ-II helical axis stellarator has been analysed. Direct losses increase with energy and a strong difference between the two injection directions appears, are produced by passing particles that loss confinement in a few μsec and the influence of birth profiles produces an increase with density. Delayed losses are very well separated in time from direct ones, are produced by particles experimenting pitch angle scattering and, most o them, correspond to trapped particles. Are much less important than the direct ones (about 1/3), decrease slowly with energy and, with C X, increase with density (an effect of initial profile). The absorption is rather independent of energy with low values at low density in reason of high shine through and C X losses, but recovers quickly with the density increase. (Author) 4 refs

  20. Automatic detection of lift-off and touch-down of a pick-up walker using 3D kinematics.

    Science.gov (United States)

    Grootveld, L; Thies, S B; Ogden, D; Howard, D; Kenney, L P J

    2014-02-01

    Walking aids have been associated with falls and it is believed that incorrect use limits their usefulness. Measures are therefore needed that characterize their stable use and the classification of key events in walking aid movement is the first step in their development. This study presents an automated algorithm for detection of lift-off (LO) and touch-down (TD) events of a pick-up walker. For algorithm design and initial testing, a single user performed trials for which the four individual walker feet lifted off the ground and touched down again in various sequences, and for different amounts of frame loading (Dataset_1). For further validation, ten healthy young subjects walked with the pick-up walker on flat ground (Dataset_2a) and on a narrow beam (Dataset_2b), to challenge balance. One 88-year-old walking frame user was also assessed. Kinematic data were collected with a 3D optoelectronic camera system. The algorithm detected over 93% of events (Dataset_1), and 95% and 92% in Dataset_2a and b, respectively. Of the various LO/TD sequences, those associated with natural progression resulted in up to 100% correctly identified events. For the 88-year-old walking frame user, 96% of LO events and 93% of TD events were detected, demonstrating the potential of the approach. Copyright © 2013 IPEM. Published by Elsevier Ltd. All rights reserved.

  1. Directed light fabrication of rhenium components

    Energy Technology Data Exchange (ETDEWEB)

    Milewski, J.O.; Thoma, D.J.; Lewis, G.K.

    1997-02-01

    Directed Light Fabrication (DLF) is a direct metal deposition process that fuses powder, delivered by gas into the focal zone of a high powered laser beam to form fully dense near-net shaped components. This is accomplished in one step without the use of molds, dies, forming, pressing, sintering or forging equipment. DLF is performed in a high purity inert environment free from the contaminants associated with conventional processing such as oxide and carbon pickup, lubricants, binding agents, cooling or cleaning agents. Applications using rhenium have historically been limited in part by its workability and cost. This study demonstrates the ability to fuse rhenium metal powder, using a DLF machine, into free standing rods and describes the associated parameter study. Microstructural comparisons between DLF deposited rhenium and commercial rhenium sheet product is performed. This research combined with existing DLF technology demonstrates the feasibility of forming complex rhenium, metal shapes directly from powder.

  2. Reduction of deposition asymmetries in directly driven ion-beam and laser targets

    International Nuclear Information System (INIS)

    Mark, J.W.K.

    1985-01-01

    The authors have developed a procedure for reducing energy-dependent asymmetry in spherical targets driven directly by ion or laser beams. This work is part of a strategy for achieving illumination symmetry in such targets, which they propose as an alternative to those in the literature. This strategy allows an axially symmetric placement of beamlets, which would be convenient for some driver or reactor scenarios. It also allows the use of beam currents or energy fluxes to help reduce deposition asymmetry

  3. Testbeam Studies on Pick-Up in Sensors with Embedded Pitch Adapters

    CERN Document Server

    Rehnisch, Laura; The ATLAS collaboration

    2017-01-01

    For silicon strip sensors, the tracking information specifications can lead to challenging requirements for wire bonding. A common strategy is to use external pitch adapters to facilitate this step in the production of detector modules. A novel approach previously discussed in [1], is to implement the pitch adapters in the sensor, by embedding a second layer of metal tracks. The use of these embedded pitch adapters (EPAs) decouples the bond pad layout of the sensor from its implant layout by moving the adaption to the sensor production step. This solution, however, can yield the risk of performance losses due to the increase of inter-strip capacitance, or unwanted capacitive coupling between the metal layers (cross-talk) or the silicon bulk and the second metal layer (pick-up). In the prototyping stage of the ATLAS tracker end-cap upgrade, where different bond-pad layouts on sensor and readout chip lead to extremely challenging wire-bonding conditions, sensors with different geometries of EPA implementations ...

  4. Laparoscopic ovarian biopsy pick-up method for goats.

    Science.gov (United States)

    Brandão, Fabiana A S; Alves, Benner G; Alves, Kele A; Souza, Samara S; Silva, Yago P; Freitas, Vicente J F; Teixeira, Dárcio I A; Gastal, Eduardo L

    2018-02-01

    Biopsy pick-up (BPU) has been considered a safe method to harvest ovarian fragments from live animals. However, no studies have been reported on the use of BPU to collect in vivo ovarian tissue in goats. The goals of this study were: (i) to test different biopsy needle sizes to collect ovarian tissue in situ using the BPU method (Experiment 1), and (ii) to study ovarian tissue features such as preantral follicle density, morphology, class distribution, and stromal cell density in ovarian fragments obtained in vivo through a laparoscopic BPU method (Experiment 2). In Experiment 1, goat ovaries (n = 20) were collected in a slaughterhouse and subjected to in situ BPU. Three needles (16, 18, and 20G) were tested. In Experiment 2, the most efficient biopsy needle from Experiment 1 was used to perform laparoscopic BPU in goats (n = 8). In Experiment 1, the recovery rate was greater (P rate). Overall, 2054 preantral follicles were recorded in 5882 histological sections analyzed. Mean preantral follicular density was 28.4 ± 1.3 follicles per cm 2 . The follicular density differed (P rate in goats. Furthermore, this study described for the first time that goat ovarian biopsy fragments have a high heterogeneity in follicular density, morphology, class distribution, and stromal cell density. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Inelastic collisions of heavy ions and their reaction mechanisms; Collisions inelastiques d'ions lourds et mecanismes de reaction

    Energy Technology Data Exchange (ETDEWEB)

    Scarpaci, J.A

    2004-06-01

    This work is dedicated to the study of inelastic collisions of heavy ions. Most experiments took place in Ganil facility. The 2 first chapters introduce the notion of inelastic scattering of heavy ions. The third chapter deals with target excitation, giant monopolar or dipolar or quadrupolar resonances ant the multi-phonon concept and presents relevant experimental results from the Ca{sup 40} + Ca{sup 40} nuclear reaction at 50 MeV/A. The fourth chapter is dedicated to nuclear processes involved in inelastic collisions: pick-up break-up mechanisms, the angular distribution of emitted protons and the towing mode. These notions are applied to the reaction Zr{sup 90}(Ar{sup 40}, Ar{sup 40}'). The fifth chapter presents the solving of the time dependent Schroedinger equation (TDSE) applied to the wave function of a particle plunged in a variable potential. TDSE solving is applied to the break-up of Be{sup 11}. These calculations have been validated by comparing them with experimental results from the nuclear reaction Ti{sup 48}(Be{sup 11}, Be{sup 10} + n + {gamma}) that is described in the chapter 6. The last chapter presents the advantages of inelastic scattering considered as a tool to study exotic nuclei.

  6. First in-situ measurements of a highly fragmented comet: ACE SWICS and WIND STICS measurements

    Science.gov (United States)

    Lepri, S. T.; Gilbert, J. A.; Rubin, M.; Zurbuchen, T.; Combi, M. R.

    2011-12-01

    While many of the characteristics of comets and their local plasma environment are obtained using remote sensing via spectroscopic methods, space-based mass spectrometers allow a unique opportunity to directly sample cometary material in situ. To date there have been only a handful of in-situ spacecraft encounters with comets, such as 1P/Halley, 103P/Hartley, 81P/Wild and others. Comet 73P/Schwassmann-Wachmann started to disintegrate in 1995, two major components B and C were recovered in 2001, and it burst into more than 36 pieces during its passage near the Earth in 2006. Serendipitously, some very distant fragmentation members, well-separated from the major identified fragments, passed between the Earth and Sun. Cometary pickup ions and possibly recombined solar wind minor ions convected past the Earth in late May 2006 and were observed by both the ACE/SWICS and WIND/STICS mass spectrometers, which are located in halo orbits around the Earth-Sun L1 Lagrange point. Most of these observations took place a few days after the main comet fragments passed through the ecliptic, when their orbits crossed the spacecraft-Sun line, suggesting additional pieces lagging far behind the main fragments. In this paper, we present the first in-situ observation of these pieces that passed very close to the spacecraft (<0.07AU) and conduct a comparative analysis of composition and characteristics of pick-up ions originating from a number of the cometary fragments. We find that the pick-up ion trail related to the comet fragments is much longer than expected. We constrain the C+/O+ and He+/He++ ratio and discuss the implications for the production rates of different fragments.

  7. Effect of ion and ion-beam mass ratio on the formation of ion-acoustic solitons in magnetized plasma in the presence of electron inertia

    International Nuclear Information System (INIS)

    Kalita, B. C.; Barman, S. N.

    2009-01-01

    The propagation of ion-acoustic solitary waves in magnetized plasma with cold ions and ion-beams together with electron inertia has been investigated theoretically through the Korteweg-de Vries equation. Subject to the drift velocity of the ion beam, the existence of compressive solitons is found to become extinct as α (=cold ion mass/ion-beam mass) tends to 0.01 when γ=0.985 (γ is the beam velocity/phase velocity). Interestingly, a transitional direction of propagation of solitary waves has been unearthed for change over, from compressive solitons to rarefactive solitons based on α and σ υ (=cosine of the angle θ made by the wave propagation direction ξ with the direction of the magnetic field) for fixed Q(=electron mass/ion mass). Further, the direction of propagation of ion-acoustic waves is found to be the deterministic factor to admit compressive or rarefactive solitons subject to beam outsource.

  8. Metallic and/or oxygen ion implantation into AlN ceramics as a method of preparation for its direct bonding with copper

    International Nuclear Information System (INIS)

    Barlak, M.; Borkowska, K.; Olesinska, W.; Kalinski, D.; Piekoszewski, J.; Werner, Z.; Jagielski, J.; Sartowska, B.

    2006-01-01

    Direct bonding (DB) process is recently getting an increasing interest as a method for producing high quality joints between aluminum nitride (AlN) ceramics and copper. The metallic ions were implanted using an MEVVA type TITAN implanter with unseparated beam. Oxygen ions were implanted using a semi-industrial ion implanter without mass separation equipped with a gaseous ion source. The substrate temperature did not exceed 200 o C. Ions were implanted at two acceleration voltages, i.e. 15 and 70 kV. The fluence range was between 1·E16 and 1·E18 cm -2 . After implantation, some of the samples were characterized by the Rutherford backscattering (RBS) method. In conclusion: (a) The investigations performed in the present work confirm an assumption that ion implantation is a very promising technique as a pretreatment of AlN ceramics for the formation of the joints with copper in direct bonding process. (b) It has been shown that titanium implantation gives the best results in comparison to other metals examined (Fe, Cr, Cu) but also in comparison to double Ti+O and O+Ti implantations

  9. Symmetry issues in a class of ion beam targets using short direct drive pulses

    International Nuclear Information System (INIS)

    Mark, J.W.K.; Lindl, J.D.

    1986-01-01

    We address a class of modified ion beam targets where the symmetry issues are ameliorated in the regime of short bursts of direct drive pulses. Short pulses are here defined so that the fractional change in target radii of peak beam energy deposition are assumed to be small (during each such direct drive burst with a fixed beam focal radius). This requirement is actually not stringent on the temporal pulse-length. In fact we show an explicit example where this can be satisfied by a ≥ 60 ns direct drive pulse-train. A new beam placement scheme is used which systematically eliminated low order spherical harmonic asymmetries. The residual asymmetries of such pulses are studied with both simple model and numerical simulations

  10. Ultrafast and directional diffusion of lithium in phosphorene for high-performance lithium-ion battery.

    Science.gov (United States)

    Li, Weifeng; Yang, Yanmei; Zhang, Gang; Zhang, Yong-Wei

    2015-03-11

    Density functional theory calculations have been performed to investigate the binding and diffusion behavior of Li in phosphorene. Our studies reveal the following findings: (1) Li atom forms strong binding with phosphorus atoms and exists in the cationic state; (2) the shallow energy barrier (0.08 eV) of Li diffusion on monolayer phosphorene along zigzag direction leads to an ultrahigh diffusivity, which is estimated to be 10(2) (10(4)) times faster than that on MoS2 (graphene) at room temperature; (3) the large energy barrier (0.68 eV) along armchair direction results in a nearly forbidden diffusion, and such strong diffusion anisotropy is absent in graphene and MoS2; (4) a remarkably large average voltage of 2.9 V is predicted in the phosphorene-based Li-ion battery; and (5) a semiconducting to metallic transition induced by Li intercalation of phosphorene gives rise to a good electrical conductivity, ideal for use as an electrode. Given these advantages, it is expected that phosphorene will present abundant opportunities for applications in novel electronic device and lithium-ion battery with a high rate capability and high charging voltage.

  11. Direct processes in ion-atom collisions at intermediate and high energies

    International Nuclear Information System (INIS)

    Rodriguez Chariarse, V.D.

    1990-01-01

    This thesis deals with direct processes induced by Zp charge ion impact on one or two electron atoms and ions at intermediate energies. At a first step, a one-dimensional collision model is used in order to prove the different theoretical methods available to study collisions at such energy range, such as: perturbative and related variational principles, and distorted wave methods. The best description of both, symmetric and asymmetric collision type, is achieved by the distorted wave methods, particularly the ones using the exact impulsive wave function. As a next step, the appropriate formulations of the wave functions employed in the one-dimensional model to describe the real 3-dimensional Coulomb interaction case are examined by using the Eikonal and impulse hypothesis. In this way, the VPS and Eikonal wave functions are reviewed, and furtherly, the Eikonal form of the extended impulse wave function is derived. The Eikonal impulse approximation (EIA) is introduced. This is a distorted wave method using the Eikonal and extended impulse wave functions. The choice of the EIA prior version, i.e., the one using extended impulse wave function in the final channel for excitation is widely discussed and justified. (Author) [es

  12. Highly selective direct determination of chlorate ions by using a newly developed potentiometric electrode based on modified smectite.

    Science.gov (United States)

    Topcu, Cihan

    2016-12-01

    A novel polyvinyl chloride membrane chlorate (ClO 3 - ) selective electrode based on modified smectite was developed for the direct determination of chlorate ions and the potentiometric performance characteristics of its were examined. The best selectivity and sensitivity for chlorate ions were obtained for the electrode membrane containing ionophore/polyvinylchloride/o-nitrophenyloctylether in composition of 12/28/60 (w/w%). The proposed electrode showed a Nernstian response toward chlorate ions at pH=7 in the concentration range of 1×10 -7 -1×10 -1 M and the limit of detection was calculated as 9×10 -8 M from the constructed response plot. The linear slope of the electrode was -61±1mVdecade -1 for chlorate activity in the mentioned linear working range. The selectivity coefficients were calculated according to both the matched potential method and the separate solution method. The calculated selectivity coefficients showed that the electrode performed excellent selectivity for chlorate ions. The potentiometric response of electrode toward chlorate ions was found to be highly reproducible. The electrode potential was stable between pH=4-10 and it had a dynamic response time of <5s. The potentiometric behavior of the electrode in partial non-aqueous medium was also investigated and the obtained results (up to 5% (v/v) alcohol) were satisfactory. The proposed electrode was used during 15 weeks without any significant change in its potential response. Additionally, the electrode was very useful in water analysis studies such as dam water, river water, tap water, and swimming pool water where the direct determination of chlorate ions was required. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Quantification of the Relative Biological Effectiveness for Ion Beam Radiotherapy: Direct Experimental Comparison of Proton and Carbon Ion Beams and a Novel Approach for Treatment Planning

    International Nuclear Information System (INIS)

    Elsaesser, Thilo; Weyrather, Wilma K.; Friedrich, Thomas; Durante, Marco; Iancu, Gheorghe; Kraemer, Michael; Kragl, Gabriele; Brons, Stephan; Winter, Marcus; Weber, Klaus-Josef; Scholz, Michael

    2010-01-01

    Purpose: To present the first direct experimental in vitro comparison of the biological effectiveness of range-equivalent protons and carbon ion beams for Chinese hamster ovary cells exposed in a three-dimensional phantom using a pencil beam scanning technique and to compare the experimental data with a novel biophysical model. Methods and Materials: Cell survival was measured in the phantom after irradiation with two opposing fields, thus mimicking the typical patient treatment scenario. The novel biophysical model represents a substantial extension of the local effect model, previously used for treatment planning in carbon ion therapy for more than 400 patients, and potentially can be used to predict effectiveness of all ion species relevant for radiotherapy. A key feature of the new approach is the more sophisticated consideration of spatially correlated damage induced by ion irradiation. Results: The experimental data obtained for Chinese hamster ovary cells clearly demonstrate that higher cell killing is achieved in the target region with carbon ions as compared with protons when the effects in the entrance channel are comparable. The model predictions demonstrate agreement with these experimental data and with data obtained with helium ions under similar conditions. Good agreement is also achieved with relative biological effectiveness values reported in the literature for other cell lines for monoenergetic proton, helium, and carbon ions. Conclusion: Both the experimental data and the new modeling approach are supportive of the advantages of carbon ions as compared with protons for treatment-like field configurations. Because the model predicts the effectiveness for several ion species with similar accuracy, it represents a powerful tool for further optimization and utilization of the potential of ion beams in tumor therapy.

  14. Rutile TiO2 nanorod arrays directly grown on Ti foil substrates towards lithium-ion micro-batteries

    International Nuclear Information System (INIS)

    Dong Shanmu; Wang Haibo; Gu Lin; Zhou Xinhong; Liu Zhihong; Han Pengxian; Wang Ya; Chen Xiao; Cui Guanglei; Chen Liquan

    2011-01-01

    Nanosized rutile TiO 2 is one of the most promising candidates for anode material in lithium-ion micro-batteries owing to their smaller dimension in ab-plane resulting in an enhanced performance for area capacity. However, few reports have yet emerged up to date of rutile TiO 2 nanorod arrays growing along c-axis for Li-ion battery electrode application. In this study, single-crystalline rutile TiO 2 nanorod arrays growing directly on Ti foil substrates have been fabricated using a template-free method. These nanorods can significantly improve the electrochemical performance of rutile TiO 2 in Li-ion batteries. The capacity increase is about 10 times in comparison with rutile TiO 2 compact layer.

  15. Bi-Directional Ion Emission from Massive Gold Cluster Impacts on Nanometric Carbon Foils

    OpenAIRE

    DeBord, J. Daniel; Della-Negra, Serge; Fernandez-Lima, Francisco A.; Verkhoturov, Stanislav V.; Schweikert, Emile A.

    2012-01-01

    Carbon cluster emission from thin carbon foils (5–40 nm) impacted by individual Aun+q cluster projectiles (95–125 qkeV, n/q = 3–200) reveals features regarding the energy deposition, projectile range, and projectile fate in matter as a function of the projectile characteristics. For the first time, the secondary ion emission from thin foils has been monitored simultaneously in both forward and backward emission directions. The projectile range and depth of emission were examined as a function...

  16. New directions for ion beam processing of optical materials

    Energy Technology Data Exchange (ETDEWEB)

    White, C W; Budai, J D; Zhu, J G; Withrow, S P [Oak Ridge National Lab., TN (United States)

    1997-03-01

    Recent developments in the use of ion implantation to modify the properties of optical materials are summarized. The use of ion implantation to form nanocrystal and quantum dots is emphasized. (author)

  17. Investigation of pUC19 DNA damage induced by direct and indirect effect of 7Li ions radiation

    International Nuclear Information System (INIS)

    Sui Li; Zhao Kui; Guo Jiyu; Ni Meinan; Kong Fuquan; Cai Minghui; Yang Mingjian

    2006-01-01

    The effect of direct and indirect action on DNA damage in 7 Li ions radiation is investigated. Using 7 Li ions generated by HI-13 tandem accelerator, three conditions of pUC19 plasmid DNA samples including dry, with or without mannitol are irradiated at different doses in air. These irradiated DNA samples are analyzed with atomic force microscopy (AFM) in nanometer-scale. The changes of DNA forms as the dose increases are observed. The results show that free radical is the main factor in DNA strand breaks induced by 7 Li ions radiation under condition of aqueous solution. The mannitol can effectively scavenge free radical and reduce the yields of DNA strand breaks. The experimental results of this report can offered valuable basal data for cancer therapy by boron neutron capture therapy (BNCT) or heavy ion radiation method, etc. (author)

  18. Vehicle Routing Problem with Time Windows and Simultaneous Delivery and Pick-Up Service Based on MCPSO

    Directory of Open Access Journals (Sweden)

    Xiaobing Gan

    2012-01-01

    Full Text Available This paper considers two additional factors of the widely researched vehicle routing problem with time windows (VRPTW. The two factors, which are very common characteristics in realworld, are uncertain number of vehicles and simultaneous delivery and pick-up service. Using minimization of the total transport costs as the objective of the extension VRPTW, a mathematic model is constructed. To solve the problem, an efficient multiswarm cooperative particle swarm optimization (MCPSO algorithm is applied. And a new encoding method is proposed for the extension VRPTW. Finally, comparing with genetic algorithm (GA and particle swarm optimization (PSO algorithm, the MCPSO algorithm performs best for solving this problem.

  19. Feasibility of corona discharge ion mobility spectrometry for direct analysis of samples extracted by dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Jafari, Mohammad T; Riahi, Farhad

    2014-05-23

    The capability of corona discharge ionization ion mobility spectrometry (CD-IMS) for direct analysis of the samples extracted by dispersive liquid-liquid microextraction (DLLME) was investigated and evaluated, for the first time. To that end, an appropriate new injection port was designed and constructed, resulting in possibility of direct injection of the known sample volume, without tedious sample preparation steps (e.g. derivatization, solvent evaporation, and re-solving in another solvent…). Malathion as a test compound was extracted from different matrices by a rapid and convenient DLLME method. The positive ion mobility spectra of the extracted malathion were obtained after direct injection of carbon tetrachloride or methanol solutions. The analyte responses were compared and the statistical results revealed the feasibility of direct analysis of the extracted samples in carbon tetrachloride, resulting in a convenient methodology. The coupled method of DLLME-CD-IMS was exhaustively validated in terms of sensitivity, dynamic range, recovery, and enrichment factor. Finally, various real samples of apple, river and underground water were analyzed, all verifying the feasibility and success of the proposed method for the easy extraction of the analyte using DLLME separation before the direct analysis by CD-IMS. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Ions kinematics in an electrostatic ion beam trap

    Energy Technology Data Exchange (ETDEWEB)

    Attia, D

    2004-06-01

    In this study, I have tried to provide a better understanding of the dynamics of ions inside an electrostatic ion beam trap. The electrostatic ion trap allows to store ions moving between two electrostatic mirrors. Although the trap has been developed already seven years ago, no direct measurement of the transversal velocity distribution of the ions has been performed. Such quantity is central for understanding the conditions under which a beam should be produced (mainly emittance) in order to be trapped by such a device. The data I have obtained during the course of this work are based on an experimental technique which relies on the direct imaging of the particles exiting the trap, as well as on numerical simulations of the ion trajectories inside the trap. I have personally been involved in the hardware development of the imaging system, the data acquisition and analysis of the data as well as il all numerical calculations presented here. These results allow us to obtain, for the first time, experimental information on the transverse phase space of the trap, and contribute to the overall understanding of the ion motion in this system. (author)

  1. A directly coupled monolithic rectangular resonator forming a robust microwave plasma ion source for SIFT-MS

    International Nuclear Information System (INIS)

    Spanel, P; Hall, E F H; Workman, C T; Smith, D

    2004-01-01

    A simple ion source is described that consists of a glass discharge tube positioned judiciously in a rectangular waveguide resonator that is directly coupled to an under-run standard magnetron. This ion source operates well with gas mixtures, including rare gases, air and water vapour in the pressure range 10-100 Pa and at magnetron powers within the range 15-40 W. The main advantage of this magnetron/cavity arrangement is the absence of mechanically adjustable parts (aerial and tuning stub), in contrast to other commonly used arrangements that combine a cavity resonator that is connected to the magnetron via a launcher and a coaxial cable

  2. Direct measurement of two-electron contributions to the ground state energy of heliumlike high-Z ions

    International Nuclear Information System (INIS)

    Stoehlker, T.; Elliott, S.R.; Marrs, R.E.

    1995-09-01

    We report on a novel technique which exploits Radiative Recombination transitions for a direct experimental determination of the two-electron contributions to the ground state energy in heliumlike high-Z ions. Results are presented of a first experiment which was conducted at an electron beam ion trap for various elements ranging from Z=32 to 83. The comparison with theoretical predictions demonstrates that the achieved precision already provides a sensitive test of second order manybody contributions and approaches the size of the two-electron (screened) Lamb shift. The ptoential of the new technique will be outlined and the capability of the ESR storage ring for future investigations will be emphasized. (orig.)

  3. A directly coupled monolithic rectangular resonator forming a robust microwave plasma ion source for SIFT-MS

    Energy Technology Data Exchange (ETDEWEB)

    Spanel, P [Trans Spectra Limited, 9 The Elms, Newcastle under Lyme, ST5 8RP (United Kingdom); Hall, E F H [Trans Spectra Limited, 9 The Elms, Newcastle under Lyme, ST5 8RP (United Kingdom); Workman, C T [Trans Spectra Limited, 9 The Elms, Newcastle under Lyme, ST5 8RP (United Kingdom); Smith, D [Trans Spectra Limited, 9 The Elms, Newcastle under Lyme, ST5 8RP (United Kingdom)

    2004-05-01

    A simple ion source is described that consists of a glass discharge tube positioned judiciously in a rectangular waveguide resonator that is directly coupled to an under-run standard magnetron. This ion source operates well with gas mixtures, including rare gases, air and water vapour in the pressure range 10-100 Pa and at magnetron powers within the range 15-40 W. The main advantage of this magnetron/cavity arrangement is the absence of mechanically adjustable parts (aerial and tuning stub), in contrast to other commonly used arrangements that combine a cavity resonator that is connected to the magnetron via a launcher and a coaxial cable.

  4. Seeking Structural Specificity: Direct Modulation of Pentameric Ligand-Gated Ion Channels by Alcohols and General Anesthetics

    Science.gov (United States)

    Trudell, James R.; Harris, R. Adron

    2014-01-01

    Alcohols and other anesthetic agents dramatically alter neurologic function in a wide range of organisms, yet their molecular sites of action remain poorly characterized. Pentameric ligand-gated ion channels, long implicated in important direct effects of alcohol and anesthetic binding, have recently been illuminated in renewed detail thanks to the determination of atomic-resolution structures of several family members from lower organisms. These structures provide valuable models for understanding and developing anesthetic agents and for allosteric modulation in general. This review surveys progress in this field from function to structure and back again, outlining early evidence for relevant modulation of pentameric ligand-gated ion channels and the development of early structural models for ion channel function and modulation. We highlight insights and challenges provided by recent crystal structures and resulting simulations, as well as opportunities for translation of these newly detailed models back to behavior and therapy. PMID:24515646

  5. Two-proton pickup studies with the (6Li,8B) reaction

    International Nuclear Information System (INIS)

    Weisenmiller, R.B.

    1976-01-01

    The ( 6 Li, 8 B) reaction has been investigated on targets of 26 Mg, 24 Mg, 16 O, 13 C, 12 C, 11 B, 10 B, and 9 Be at a bombarding energy of 80.0 MeV, and on targets of 16 O, 12 C, 9 Be, 7 Li, and 6 Li at a bombarding energy of 93.3 MeV. Only levels consistent with direct, single-step two-proton pickup reaction mechanisms were observed to be strongly populated. On T/sub z/ = 0 targets, the spectroscopic selectivity of this reaction resembles that of the analogous (p,t) reaction. Additionally, these data demonstrate the dominance of spatially symmetric transfer of the two protons. On T/sub z/ greater than 0 targets the ( 6 Li, 8 B) reaction was employed to locate two previously unreported levels (at 7.47 +- 0.05 MeV and 8.86 +- 0.07 MeV) in the T/sub z/ = 2 nuclide 24 Ne and to establish the low-lying 1p-shell states in the T/sub z/ = 3 / 2 nuclei 11 Be, 9 Li, and 7 He. However, no evidence was seen for any narrow levels in the T/sub z/ = 3 / 2 nuclide 5 H nor for any narrow excited states in 7 He. The angular distributions reported here are rather featureless and decrease monotonically with increasing angle. This behavior can be shown by a semi-classical reaction theory to be a consequence of the reaction kinematics. A semi-classical approach also suggests that the kinematic term in the transition matrix element is only weakly dependent upon the angular momentum transfer (which is consistent with simple Distorted Wave Born Approximation calculations). However, only qualitative agreement was obtained between the observed relative transition yields and semi-classical predictions, using the two-nucleon coefficients of fractional parentage of Cohen and Kurath, probably due to the limitations of the semi-classical reaction theory

  6. Listing of 502 Times When the Ulysses Magnetic Fields Instrument Observed Waves Due to Newborn Interstellar Pickup Protons

    International Nuclear Information System (INIS)

    Cannon, Bradford E.; Smith, Charles W.; Isenberg, Philip A.; Vasquez, Bernard J.; Joyce, Colin J.; Murphy, Neil; Nuno, Raquel G.

    2017-01-01

    In two earlier publications we analyzed 502 intervals of magnetic waves excited by newborn interstellar pickup protons that were observed by the Ulysses spacecraft. Due to the considerable effort required in identifying these events, we provide a list of the times for the 502 wave event intervals previously identified. In the process, we provide a brief description of how the waves were found and what their properties are. We also remind the reader of the conditions that permit the waves to reach observable levels and explain why the waves are not seen more often.

  7. Listing of 502 Times When the Ulysses Magnetic Fields Instrument Observed Waves Due to Newborn Interstellar Pickup Protons

    Energy Technology Data Exchange (ETDEWEB)

    Cannon, Bradford E. [Physics Department, Florida State University, Tallahassee, Florida (United States); Smith, Charles W.; Isenberg, Philip A.; Vasquez, Bernard J.; Joyce, Colin J. [Physics Department and Space Science Center, Institute for the Study of Earth, Oceans, and Space, University of New Hampshire, Durham, New Hampshire (United States); Murphy, Neil [Jet Propulsion Laboratory, Mail Stop 180-600, 4800 Oak Grove Drive, Pasadena, California (United States); Nuno, Raquel G., E-mail: bc13h@my.fsu.edu, E-mail: Charles.Smith@unh.edu, E-mail: Phil.Isenberg@unh.edu, E-mail: Bernie.Vasquez@unh.edu, E-mail: Colin.Joyce@unh.edu, E-mail: Neil.Murphy@jpl.nasa.gov, E-mail: rgnuno@ucla.edu [Department of Earth, Planetary, and Space Sciences, University of California, Los Angeles, Los Angeles, CA (United States)

    2017-05-01

    In two earlier publications we analyzed 502 intervals of magnetic waves excited by newborn interstellar pickup protons that were observed by the Ulysses spacecraft. Due to the considerable effort required in identifying these events, we provide a list of the times for the 502 wave event intervals previously identified. In the process, we provide a brief description of how the waves were found and what their properties are. We also remind the reader of the conditions that permit the waves to reach observable levels and explain why the waves are not seen more often.

  8. Ion mobility sensor system

    Science.gov (United States)

    Xu, Jun; Watson, David B.; Whitten, William B.

    2013-01-22

    An ion mobility sensor system including an ion mobility spectrometer and a differential mobility spectrometer coupled to the ion mobility spectrometer. The ion mobility spectrometer has a first chamber having first end and a second end extending along a first direction, and a first electrode system that generates a constant electric field parallel to the first direction. The differential mobility spectrometer includes a second chamber having a third end and a fourth end configured such that a fluid may flow in a second direction from the third end to the fourth end, and a second electrode system that generates an asymmetric electric field within an interior of the second chamber. Additionally, the ion mobility spectrometer and the differential mobility spectrometer form an interface region. Also, the first end and the third end are positioned facing one another so that the constant electric field enters the third end and overlaps the fluid flowing in the second direction.

  9. Review of theoretical conceptions on regimes of oxidation and hydrogen pickup in Zr-alloys

    International Nuclear Information System (INIS)

    Likhanskii, V.; Evdokimov, I.

    2008-01-01

    In this paper the following issues are presented: 1) Experimental observations published in the journals on corrosion regimes of zirconium alloys of various compositions both for ex-pile oxidation experiments and for in-pile operating conditions of the materials. Factors experimentally stated on the effect of alloying composition, microstructure and texture on the rate of uniform corrosion and susceptibility of alloys to nodular corrosion. 2) Phenomenological models existing in publications, which describe conditions of uniform and nodular corrosion for Zr-alloys of various composition and microstructures, effect of irradiation and oxidizing medium; 3) Experimental data and phenomenological models describing regimes of hydrogen absorption in zirconium alloys; 4) Examples of application of physical models in explaining regimes, peculiarities of oxidation and hydrogen pickup for zirconium claddings of various alloying composition and microstructure

  10. Direct-driven target implosion in heavy ion fusion

    International Nuclear Information System (INIS)

    Noguchi, K.; Suzuki, T.; Kurosaki, T.; Barada, D.; Kawata, S.; Ma, Y. Y.; Ogoyski, A. I.

    2016-01-01

    In inertial confinement fusion, the driver beam illumination non-uniformity leads a degradation of fusion energy output. A fuel target alignment error would happen in a fusion reactor; the target alignment error induces heavy ion beam illumination non-uniformity on a target. On the other hand, heavy ion beam accelerator provides a capability to oscillate a beam axis with a high frequency. The wobbling beams may provide a new method to reduce or smooth the beam illumination non-uniformity. First we study the effect of driver irradiation non-uniformity induced by the target alignment error (dz) on the target implosion. We found that dz should be less than about 130 μm for a sufficient fusion energy output. We also optimize the wobbling scheme. The spiral wobbling heavy ion beams would provide a promissing scheme to the uniform beam illumination. (paper)

  11. Rotation characteristics of main ions and impurity ions in H-mode tokamak plasma

    International Nuclear Information System (INIS)

    Kim, J.; Burrell, K.H.; Gohil, P.; Groebner, R.J.; Kim, Y.; St. John, H.E.; Seraydarian, R.P.; Wade, M.R.

    1994-01-01

    Poloidal and toroidal rotation of the main ions (He 2+ ) and the impurity ions (C 6+ and B 5+ ) in H-mode helium plasmas have been measured via charge exchange recombination spectroscopy in the DIII-D tokamak. It was discovered that the main ion poloidal rotation is in the ion diamagnetic drift direction while the impurity ion rotation is in the electron diamagnetic drift direction, in qualitative agreement with the neoclassical theory. The deduced radial electric field in the edge is of the same negative-well shape regardless of which ion species is used, validating the fundamental nature of the electric field in L-H transition phenomenology

  12. Develop and pilot test smart phone/tablet app for paratransit demand-response passenger pick-up alerts to assist passengers with disabilities and reduce no-shows and dwell times.

    Science.gov (United States)

    2016-12-01

    This research produced an arrival notification system for paratransit passengers with disabilities. Almost all existing curb-to-curb paratransit services have significantly large pick-up time window ranging from 20 to 40 minutes from the scheduled ti...

  13. Ship Routing with Pickup and Delivery for a Maritime Oil Transportation System: MIP Modeland Heuristics

    DEFF Research Database (Denmark)

    Rodrigues, Vinicius Picanco; Morabito, Reinaldo; Yamashita, Denise

    2016-01-01

    This paper examines a ship routing problem with pickup and delivery and time windowsfor maritime oil transportation, motivated by the production and logistics activities of an oil companyoperating in the Brazilian coast. The transportation costs from offshore platforms to coastal terminalsare...... application of two tailor-made MIP heuristics, based on relax-and-fix and timedecomposition procedures. The model minimizes fuel costs of a heterogeneous fleet of oil tankersand costs related to freighting contracts. The model also considers company-specific constraints foroffshore oil transportation....... Computational experiments based on the mathematical models and therelated MIP heuristics are presented for a set of real data provided by the company, which confirmthe potential of optimization-based methods to find good solutions for problems of moderate sizes....

  14. Recharging of a screened ion on the molecular ion

    International Nuclear Information System (INIS)

    Karbovanets, M.I.; Lazur, V.Yu.; Yudin, G.L.; Gosudarstvennyj Komitet po Ispol'zovaniyu Atomnoj Ehnergii SSSR, Obninsk. Fiziko-Ehnergeticheskij Inst.)

    1987-01-01

    Charge exchange of a screened ion on a molecular ion is studied in the Oppenheimer-Brinkman-Cramers approximation. To calculate ion exchange probabilities and cross sections summed over the final degenerated electron states method of Green functions analogous to that applied earlier in the direct Coulomb excitation theory and atomic ionization is developed

  15. Heavy ion program at BNL: AGS, RHIC [Relativistic Heavy Ion Collider

    International Nuclear Information System (INIS)

    Barton, D.S.

    1987-01-01

    With the recent commissioning of fixed target, heavy ion physics at the AGS, Brookhaven National Laboratory (BNL) has embarked on a long range program in support of relativistic heavy ion research. Acceleration of low mass heavy ions (up to sulfur) to an energy of about 14.5 GeV/nucleon is possible with the direct connection of the BNL Tandem Van de Graaff and AGS accelerators. When completed, the new booster accelerator will provide heavy ions over the full mass range for injection and subsequent acceleration in the AGS. BNL is now engaged in an active R and D program directed toward the proposed Relativistic Heavy Ion Collider (RHIC). The results of the first operation of the low mass heavy ion program will be reviewed, and future expectations discussed. The expected performance for the heavy ion operation of the booster will be described and finally, the current status and outlook for the RHIC facility will be presented

  16. Auroral ion beams and ion acoustic wave generation by fan instability

    Energy Technology Data Exchange (ETDEWEB)

    Vaivads, A

    1996-04-01

    Satellite observations indicate that efficient energy transport among various plasma particles and between plasma waves and plasma particles is taking place in auroral ion beam regions. These observations show that two characteristic wave types are associated with the auroral ion beam regions: electrostatic hydrogen cyclotron waves with frequencies above hydrogen gyrofrequency, and low frequency waves with frequencies below hydrogen gyrofrequency. We speculate that the low frequency waves can be ion acoustic waves generated through the fan instability. The presence of a cold background ion component is necessary for the onset of this instability. A cold ion component has been directly observed and has been indirectly suggested from observations of solitary wave structures. The wave-particle interaction during the development of the fan instability results in an efficient ion beam heating in the direction perpendicular to the ambient magnetic field. The fan instability development and the ion beam heating is demonstrated in a numerical particle simulation. 23 refs, 16 figs.

  17. Direct view on the phase evolution in individual LiFePO4 nanoparticles during Li-ion battery cycling.

    Science.gov (United States)

    Zhang, Xiaoyu; van Hulzen, Martijn; Singh, Deepak P; Brownrigg, Alex; Wright, Jonathan P; van Dijk, Niels H; Wagemaker, Marnix

    2015-09-23

    Phase transitions in Li-ion electrode materials during (dis)charge are decisive for battery performance, limiting high-rate capabilities and playing a crucial role in the cycle life of Li-ion batteries. However, the difficulty to probe the phase nucleation and growth in individual grains is hindering fundamental understanding and progress. Here we use synchrotron microbeam diffraction to disclose the cycling rate-dependent phase transition mechanism within individual particles of LiFePO4, a key Li-ion electrode material. At low (dis)charge rates well-defined nanometer thin plate-shaped domains co-exist and transform much slower and concurrent as compared with the commonly assumed mosaic transformation mechanism. As the (dis)charge rate increases phase boundaries become diffuse speeding up the transformation rates of individual grains. Direct observation of the transformation of individual grains reveals that local current densities significantly differ from what has previously been assumed, giving new insights in the working of Li-ion battery electrodes and their potential improvements.

  18. Direct seawater desalination by ion concentration polarization

    Science.gov (United States)

    Kim, Sung Jae; Ko, Sung Hee; Kang, Kwan Hyoung; Han, Jongyoon

    2010-04-01

    A shortage of fresh water is one of the acute challenges facing the world today. An energy-efficient approach to converting sea water into fresh water could be of substantial benefit, but current desalination methods require high power consumption and operating costs or large-scale infrastructures, which make them difficult to implement in resource-limited settings or in disaster scenarios. Here, we report a process for converting sea water (salinity ~500 mM or ~30,000 mg l-1) to fresh water (salinity water is divided into desalted and concentrated streams by ion concentration polarization, a phenomenon that occurs when an ion current is passed through ion-selective membranes. During operation, both salts and larger particles (cells, viruses and microorganisms) are pushed away from the membrane (a nanochannel or nanoporous membrane), which significantly reduces the possibility of membrane fouling and salt accumulation, thus avoiding two problems that plague other membrane filtration methods. To implement this approach, a simple microfluidic device was fabricated and shown to be capable of continuous desalination of sea water (~99% salt rejection at 50% recovery rate) at a power consumption of less than 3.5 Wh l-1, which is comparable to current state-of-the-art systems. Rather than competing with larger desalination plants, the method could be used to make small- or medium-scale systems, with the possibility of battery-powered operation.

  19. Comments on the current status and possible future directions of research on heavy-ion interactions near the Coulomb barrier

    International Nuclear Information System (INIS)

    Satchler, G.R.

    1990-01-01

    This paper contains comments on the current status and possible future directions of research on heavy-ion interactions near the Coulomb barrier. Fusion reactions, elastic and inelastic scattering and transfer reactions are discussed

  20. In-situ observations of a bi-modal ion distribution in the outer coma of comet P/Halley

    Science.gov (United States)

    Thomsen, M. F.; Feldman, W. C.; Wilken, B.; Jockers, K.; Stuedemann, W.

    1987-01-01

    Observations obtained by the Johnstone Plasma Analyzer on the Giotto fly-by of comet Halley showed a fairly sudden decrease in the count rate of energetic (about 30 KeV) water-group ions inside about 500,000 km from the nucleus. This decrease was accompanied by the appearance of a new water-group ion population at slightly lower energies (less than 10 KeV). Close inspection reveals that this lower-energy peak was also present somewhat earlier in the postshock flow but only became prominent near the sudden transition just described. It is shown that the observed bimodal ion distribution is well explained in terms of the velocity history of the accreting solar wind flow in the outer coma. The decline in count rate of the energetic pick-up distribution is due to a relatively sudden slowing of the bulk flow there and not to a loss of particles. Hence, charge-exchange cooling of the flow is probably not important at these distances from the nucleus. The observations suggest that pitch-angle scattering is fairly efficient at least after the bow shock, but that energy diffusion is probably not very efficient.

  1. High-ion temperature experiments with negative-ion-based NBI in LHD

    International Nuclear Information System (INIS)

    Takeiri, Y.; Morita, S.; Tsumori, K.; Ikeda, K.; Oka, Y.; Osakabe, M.; Nagaoka, K.; Goto, M.; Miyazawa, J.; Masuzaki, S.; Ashikawa, N.; Yokoyama, M.; Narihara, K.; Yamada, I.; Kubo, S.; Shimozuma, T.; Inagaki, S.; Tanaka, K.; Peterson, B.J.; Ida, K.; Kaneko, O.; Komori, A.; Murakami, S.

    2005-01-01

    High-Z plasmas have been produced with Ar- and/or Ne-gas fuelling to increase the ion temperature in the LHD plasmas heated with the high-energy negative-ion-based NBI. Although the electron heating is dominant in the high-energy NBI heating, the direct ion heating power is much enhanced effectively in low-density plasmas due to both an increase in the beam absorption (ionisation) power and a reduction of the ion density in the high-Z plasmas. Intensive Ne- and/or Ar-glow discharge cleaning works well to suppress dilution of the high-Z plasmas with the wall-absorbed hydrogen. As a result, the ion temperature increases with an increase in the ion heating power normalized by the ion density, and reaches 10 keV. An increase in the ion temperature is also observed with an addition of the centrally focused ECRH to the low-density and high-Z NBI plasma, suggesting improvement of the ion transport. The results obtained in the high-Z plasma experiments with the high-energy NBI heating indicate that an increase in the direct ion heating power and improvement of the ion transport are essential to the ion temperature rise, and that a high-ion temperature would be obtained as well in hydrogen plasmas with low-energy positive-NBI heating which is planed in near future in LHD. (author)

  2. A NEW MODEL FOR THE HELIOSPHERE’S “IBEX RIBBON”

    Energy Technology Data Exchange (ETDEWEB)

    Giacalone, J.; Jokipii, J. R. [Department of Planetary Sciences, University of Arizona, Tucson, AZ (United States)

    2015-10-10

    We present a model for the narrow, ribbon-like enhancement in the emission of ∼keV energetic neutral atoms (ENA) coming from the outer heliosphere, coinciding roughly with the plane of the very local interstellar magnetic field (LISMF). We show that the pre-existing turbulent LISMF has sufficient amplitude in magnitude fluctuations to efficiently trap ions with initial pitch-angles near 90°, primarily by magnetic mirroring, leading to a narrow region of enhanced pickup-proton intensity. The pickup protons interact with cold interstellar hydrogen to produce ENAs seen at 1 AU. The computed width of the resulting ribbon of emission is consistent with observations. We also present results from a numerical model that are also generally consistent with the observations. Our interpretation relies only on the pre-existing turbulent interstellar magnetic field to trap the pickup protons. This leads to a broader local pitch-angle distribution compared to that of a ring. Our numerical model also predicts that the ribbon is double-peaked with a central depression. This is a further consequence of the (primarily) magnetic mirroring of pickup ions with pitch-angles close to 90° in the pre-existing, turbulent interstellar magnetic field.

  3. Automatic pickup of arrival time of channel wave based on multi-channel constraints

    Science.gov (United States)

    Wang, Bao-Li

    2018-03-01

    Accurately detecting the arrival time of a channel wave in a coal seam is very important for in-seam seismic data processing. The arrival time greatly affects the accuracy of the channel wave inversion and the computed tomography (CT) result. However, because the signal-to-noise ratio of in-seam seismic data is reduced by the long wavelength and strong frequency dispersion, accurately timing the arrival of channel waves is extremely difficult. For this purpose, we propose a method that automatically picks up the arrival time of channel waves based on multi-channel constraints. We first estimate the Jaccard similarity coefficient of two ray paths, then apply it as a weight coefficient for stacking the multichannel dispersion spectra. The reasonableness and effectiveness of the proposed method is verified in an actual data application. Most importantly, the method increases the degree of automation and the pickup precision of the channel-wave arrival time.

  4. Longitudinal beam diagnostic from a distributed electrostatic pick-up in CERN's ELENA ring

    CERN Document Server

    Angoletta, M E; Federmann, S; Molendijk, J; Sanchez-Quesada, J; Secouet, P J; Søby, L; Pedersen, F; Timmins, M

    2013-01-01

    The CERN Extra Low ENergy Antiproton (ELENA) Ring is a new synchrotron that will be commissioned in 2016 to further decelerate the antiprotons coming from CERN’s Antiproton Decelerator (AD). Required longitudinal diagnostics include the intensity measurement for bunched and debunched beam and the measurement of Dp/p to assess the electron cooling performance. A novel method for the calculation of these parameters is proposed for ELENA, where signals from the twenty electrostatic Pick-Ups (PU) used for orbit measurements will be combined to improve the signal-to-noise ratio. This requires that the signals be digitally down-converted, rotated and summed so that the many electrostatic PUs will function as a single, distributed PU from the processing system viewpoint. This method includes some challenges and will not be used as the baseline longitudinal diagnostics for the initial ELENA operation. This paper gives an overview of the hardware and digital signal processing involved, as well as of the challenges t...

  5. Design developments for the ITER in-Vessel equilibrium pick-up Coils and Halo current Sensors

    International Nuclear Information System (INIS)

    Chitarin, G; Grando, L.; Pomaro, N.; Peruzzo, S.; Taccon, C.

    2006-01-01

    The ITER magnetic diagnostics must provide essential information to be used both for plasma diagnostic purposes, and as feedback signals for the machine control loops. Some of the sensors have to be installed in a hostile environment characterized by severe neutron irradiation and plasma heat loads, which can reduce the sensor lifetime (due to mechanical and electrical damage) and also generate undesired DC signals, which might compromise the accuracy of the measurements obtained by time-integration. The paper is focused on the design development and optimization of a typical in-vessel tangential pick-up Coil. The work is aimed to achieve the required measurement precision in spite of Radiation Induced Electromotive Force (RIEMF) and Radiation Induced Thermo-Electric Sensitivity (RITES), which have recently been documented to take place in Mineral Insulated Cables (MIC). To this purpose, a substantial reduction of the thermal gradient and the maximum temperature due to nuclear heating in the pick-up coils is considered necessary. Within the limits of several heavy engineering constraints, a new concept of magnetic pick up coil has been developed. A winding made of a ceramic-coated conductor (instead of a MIC) and '' impregnated '' with ceramic filler is proposed. Different material choices for the coil support structure have been investigated. Similar issues are related to the Halo Sensor design. The possibility of replacing the circular tubes used as support of the Rogowski coils with a ceramic support in order to avoid the non-linear effect of the magnetic material has also been studied. The replacement of the MIC of the winding with a ceramic-coated wire is also investigated in order to increase of the effective area of the sensor. The paper includes also a critical review of each stage of the measurement chain (probes, cabling, conditioning electronics and data acquisition) in order to assess the compliance with the overall system precision that is required for

  6. Electron beam propagation in the ion focused regime (IFR) with the experimental test accelerator (ETA)

    International Nuclear Information System (INIS)

    Struve, K.W.; Lauer, E.J.; Chambers, F.W.

    1983-01-01

    The IFR is a well-known stable, low pressure (0.10 to 0.120 torr in air) propagation window. Secondary electrons created by collisions of beam electrons with gas atoms are rapidly expelled by the strong radial electric field of the beam charge. The ions that remain inside the beam partially neutralize the electric field, allowing magnetic pinch forces to focus the beam. Experiments with the ETA beam have re-verified this stable window and are reported. Image forces from a close wall IFR propagation tank are also experimentally shown to center the beam and damp transverse oscillations. Results of experiments using 5 and 15 cm dia beam tubes are reported. For p tau > 2 torr-nsec (gas pressure x time into pulse the beam charge becomes completely neutralized by the ions, allowing a build up of plasma and resultant beam-plasma instabilities. The onset of these instabilities has been measured using rf pickup loops (0 to 2 GHz) and microwave detectors (6 to 40 GHz), and are also reported

  7. Heavy-ion fusion: future promise and future directions

    International Nuclear Information System (INIS)

    Dudziak, D.J.; Saylor, W.W.; Pendergrass, J.H.

    1986-01-01

    The previous papers in this heavy-ion fusion special session have described work performed as part of the Heavy-Ion Fusion Systems Assessment (HIFSA) Project. Key technical issues in the design and costing of targets, induction linacs, beam transport, reactor, balance of plant, and systems integration have been identified and described. The HIFSA systems model was used to measure the relative value of improvements in physics understanding and technology developments in many different areas. Within the limits of our 1986 knowledge and imagination, this study defines the most attractive heavy-ion fusion (HIF) power plant concepts. The project has deliberately avoided narrowing the focus to a point facility design; thus, the generic systems modeling capability developed in the process allows for relative comparisons among design options. We will describe what are thought to be achievable breakthroughs and what the relative significance of the breakthroughs will be, although the specific mechanism for achieving some breakthroughs may not be clear at this point. This degree of optimism concerning such breakthroughs is probably at least as conservative as that used in other fusion assessments

  8. Cobalt Oxide Porous Nanofibers Directly Grown on Conductive Substrate as a Binder/Additive-Free Lithium-Ion Battery Anode with High Capacity.

    Science.gov (United States)

    Liu, Hao; Zheng, Zheng; Chen, Bochao; Liao, Libing; Wang, Xina

    2017-12-01

    In order to reduce the amount of inactive materials, such as binders and carbon additives in battery electrode, porous cobalt monoxide nanofibers were directly grown on conductive substrate as a binder/additive-free lithium-ion battery anode. This electrode exhibited very high specific discharging/charging capacities at various rates and good cycling stability. It was promising as high capacity anode materials for lithium-ion battery.

  9. Direct-write three-dimensional nanofabrication of nanopyramids and nanocones on Si by nanotumefaction using a helium ion microscope

    Science.gov (United States)

    Zhang, L.; Heinig, N. F.; Bazargan, S.; Abd-Ellah, M.; Moghimi, N.; Leung, K. T.

    2015-06-01

    The recently commercialized helium ion microscope (HIM) has already demonstrated its outstanding imaging capabilities in terms of resolution, surface sensitivity, depth of field and ease of charge compensation. Here, we show its exceptional patterning capabilities by fabricating dense lines and three-dimensional (3D) nanostructures on a Si substrate. Small focusing spot size and confined ion-Si interaction volume of a high-energy helium ion beam account for the high resolution in HIM patterning. We demonstrate that a set of resolvable parallel lines with a half pitch as small as 3.5 nm can be achieved. During helium ion bombardment of the Si surface, implantation outperforms milling due to the small mass of the helium ions, which produces tumefaction instead of depression in the Si surface. The Si surface tumefaction is the result of different kinetic processes including diffusion, coalescence and nanobubble formation of the implanted ions, and is found to be very stable structurally at room temperature. Under appropriate conditions, a linear dependence of the surface swollen height on the ion doses can be observed. This relation has enabled us to fabricate nanopyramids and nanocones, thus demonstrating that HIM patterning provides a new ‘bottom-up’ approach to fabricate 3D nanostructures. This surface tumefaction method is direct, both positioning and height accurate, and free of resist, etch, mode and precursor, and it promises new applications in nanoimprint mold fabrication and photomask clear defect reparation.

  10. Heavy-ion fusion: Future promise and future directions

    International Nuclear Information System (INIS)

    Dudziak, D.J.; Saylor, W.W.; Pendergrass, J.H.

    1986-01-01

    The previous several papers in this heavy-ion fusion special session have described work that has taken place as part of the Heavy-Ion Fusion Systems Assessment (HIFSA) project. Key technical issues in the design and costing of targets, accelerator systems, beam transport, reactor and balance-of-plant, and systems integration have been identified and described. The HIFSA systems model was used to measure the relative value of improvements in physics understanding and technology developments in many different areas. The result of this study has been to, within the limits of our 1986 imagination and creativity, define the ''most attractive'' future heavy-ion fusion (HIF) power plant at some time in the future (beyond the year 2020 in this case). The project has specifically avoided narrowing the focus to a point facility design; thus, the generic systems modeling capability developed in the process allows for a relative comparison among design options. The authors describe what are thought to be achievable breakthroughs and what the relative significance of the breakthroughs will be, although the specific mechanism for achieving some breakthroughs may not be clear at this point

  11. Non-equilibrium statistical mechanical approach for describing heavy ion reactions

    International Nuclear Information System (INIS)

    Sventek, J.S.

    1979-01-01

    With the availability of heavy-ion projectiles (A > 4) at low to intermediate energies (4 < E/A < 10), products showing various stages of relaxation for certain macroscopic variables (center-of-mass energy, orbital angular momentum, etc.) were produced in various reactions. The distributions for these macroscopic variables showed a correlation between the stage of relaxation reached and the net amount of mass transfer which had occurred in the reaction. There was also evidence that there was an asymmetry in the number of net transfers necessary for complete relaxation between stripping ad pickup reactions. A model for describing the time-evolution of these reactions has been formulated, the keystone of which is a master-equation approach for describing the time-dependence of the mass-asymmetry. This, coupled with deterministic equations of motion for the other macroscopic coordinates in the reaction lead to calculated distributions which provide an excellent qualitative description of these reactions, and, in some cases, quantitatively reproduce the experimental data quite well

  12. Two-proton pickup studies with the (6Li,8B) reaction

    Energy Technology Data Exchange (ETDEWEB)

    Weisenmiller, R.B.

    1976-12-03

    The (/sup 6/Li,/sup 8/B) reaction has been investigated on targets of /sup 26/Mg, /sup 24/Mg, /sup 16/O, /sup 13/C, /sup 12/C, /sup 11/B, /sup 10/B, and /sup 9/Be at a bombarding energy of 80.0 MeV, and on targets of /sup 16/O, /sup 12/C, /sup 9/Be, /sup 7/Li, and /sup 6/Li at a bombarding energy of 93.3 MeV. Only levels consistent with direct, single-step two-proton pickup reaction mechanisms were observed to be strongly populated. On T/sub z/ = 0 targets, the spectroscopic selectivity of this reaction resembles that of the analogous (p,t) reaction. Additionally, these data demonstrate the dominance of spatially symmetric transfer of the two protons. On T/sub z/ greater than 0 targets the (/sup 6/Li,/sup 8/B) reaction was employed to locate two previously unreported levels (at 7.47 +- 0.05 MeV and 8.86 +- 0.07 MeV) in the T/sub z/ = 2 nuclide /sup 24/Ne and to establish the low-lying 1p-shell states in the T/sub z/ = /sup 3///sub 2/ nuclei /sup 11/Be, /sup 9/Li, and /sup 7/He. However, no evidence was seen for any narrow levels in the T/sub z/ = /sup 3///sub 2/ nuclide /sup 5/H nor for any narrow excited states in /sup 7/He. The angular distributions reported here are rather featureless and decrease monotonically with increasing angle. This behavior can be shown by a semi-classical reaction theory to be a consequence of the reaction kinematics. A semi-classical approach also suggests that the kinematic term in the transition matrix element is only weakly dependent upon the angular momentum transfer (which is consistent with simple Distorted Wave Born Approximation calculations). However, only qualitative agreement was obtained between the observed relative transition yields and semi-classical predictions, using the two-nucleon coefficients of fractional parentage of Cohen and Kurath, probably due to the limitations of the semi-classical reaction theory.

  13. Direct-write three-dimensional nanofabrication of nanopyramids and nanocones on Si by nanotumefaction using a helium ion microscope

    International Nuclear Information System (INIS)

    Zhang, L; Heinig, N F; Bazargan, S; Abd-Ellah, M; Moghimi, N; Leung, K T

    2015-01-01

    The recently commercialized helium ion microscope (HIM) has already demonstrated its outstanding imaging capabilities in terms of resolution, surface sensitivity, depth of field and ease of charge compensation. Here, we show its exceptional patterning capabilities by fabricating dense lines and three-dimensional (3D) nanostructures on a Si substrate. Small focusing spot size and confined ion–Si interaction volume of a high-energy helium ion beam account for the high resolution in HIM patterning. We demonstrate that a set of resolvable parallel lines with a half pitch as small as 3.5 nm can be achieved. During helium ion bombardment of the Si surface, implantation outperforms milling due to the small mass of the helium ions, which produces tumefaction instead of depression in the Si surface. The Si surface tumefaction is the result of different kinetic processes including diffusion, coalescence and nanobubble formation of the implanted ions, and is found to be very stable structurally at room temperature. Under appropriate conditions, a linear dependence of the surface swollen height on the ion doses can be observed. This relation has enabled us to fabricate nanopyramids and nanocones, thus demonstrating that HIM patterning provides a new ‘bottom-up’ approach to fabricate 3D nanostructures. This surface tumefaction method is direct, both positioning and height accurate, and free of resist, etch, mode and precursor, and it promises new applications in nanoimprint mold fabrication and photomask clear defect reparation. (paper)

  14. Direct measurement of the plasma response to electrostatic ion waves

    International Nuclear Information System (INIS)

    Sarfaty, M.; DeSouza-Machado, S.; Skiff, F.

    1995-01-01

    Plasma wave-wave and wave-particle interactions are studied in a linear magnetized plasma. The relatively quiet plasma is produced by an argon gas-discharge. The plasma density is n e ≅ 10 9 cm -3 and the electron/ion temperatures are T e ≅ 5eV and T i = 0.05eV. A grid and a four ring antenna, both mounted on a scanning carriage, are used to launch electrostatic ion waves in the plasma. Laser Induced Fluorescence measurements of both the linear and the nonlinear plasma response to the wave fields are presented. The Vlasov-Poisson equations are used to explain the measured zero, first and second order terms of the ion distribution function in the presence of wave fields. In addition to the broadening (heating) of the ion distribution as the authors increase the wave amplitudes, induced plasma flows are observed both along and across the magnetic field

  15. Dawn-dusk asymmetry induced by the Parker spiral angle in the plasma dynamics around comet 67P/Churyumov-Gerasimenko

    Science.gov (United States)

    Behar, E.; Tabone, B.; Nilsson, H.

    2018-05-01

    When interacting, the solar wind and the ionised atmosphere of a comet exchange energy and momentum. Our aim is to understand the influence of the average Parker spiral configuration of the solar wind magnetic field on this interaction. We compare the theoretical expectations of an analytical generalised gyromotion with Rosetta observations at comet 67P/Churyumov-Gerasimenko. A statistical approach allows one to overcome the lack of upstream solar wind measurement. We find that additionally to their acceleration along (for cometary pick-up ions) or against (for solar wind ions) the upstream electric field orientation and sense, the cometary pick-up ions are drifting towards the dawn side of the coma, while the solar wind ions are drifting towards the dusk side of the coma, independent of the heliocentric distance. The dynamics of the interaction is not taking place in a plane, as often assumed in previous works.

  16. Ion Channel Conformation and Oligomerization Assessment by Site-Directed Spin Labeling and Pulsed-EPR.

    Science.gov (United States)

    Pliotas, Christos

    2017-01-01

    Mechanosensitive (MS) ion channels are multimeric integral membrane proteins that respond to increased lipid bilayer tension by opening their nonselective pores to release solutes and relieve increased cytoplasmic pressure. These systems undergo major conformational changes during gating and the elucidation of their mechanism requires a deep understanding of the interplay between lipids and proteins. Lipids are responsible for transmitting lateral tension to MS channels and therefore play a key role in obtaining a molecular-detail model for mechanosensation. Site-directed spin labeling combined with electron paramagnetic resonance (EPR) spectroscopy is a powerful spectroscopic tool in the study of proteins. The main bottleneck for its use relates to challenges associated with successful isolation of the protein of interest, introduction of paramagnetic labels on desired sites, and access to specialized instrumentation and expertise. The design of sophisticated experiments, which combine a variety of existing EPR methodologies to address a diversity of specific questions, require knowledge of the limitations and strengths, characteristic of each particular EPR method. This chapter is using the MS ion channels as paradigms and focuses on the application of different EPR techniques to ion channels, in order to investigate oligomerization, conformation, and the effect of lipids on their regulation. The methodology we followed, from the initial strategic selection of mutants and sample preparation, including protein purification, spin labeling, reconstitution into lipid mimics to the complete set-up of the pulsed-EPR experiments, is described in detail. © 2017 Elsevier Inc. All rights reserved.

  17. Direct infusion electrospray ionization–ion mobility–mass spectrometry for comparative profiling of fatty acids based on stable isotope labeling

    Energy Technology Data Exchange (ETDEWEB)

    Leng, Jiapeng, E-mail: jpleng@126.com [Department of Chemical Engineering, North University of China, Taiyuan 030051 (China); Guan, Qing [Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Shanghai 200032 (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032 (China); Sun, Tuanqi, E-mail: tuanqisun@163.com [Department of Head and Neck Surgery, Fudan University Shanghai Cancer Center (FUSCC), Shanghai 200032 (China); Department of Oncology, Shanghai Medical College, Fudan University, Shanghai 200032 (China); Wang, Haoyang [National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032 (China); Cui, Jianlan; Liu, Qinghao [Department of Chemical Engineering, North University of China, Taiyuan 030051 (China); Zhang, Zhixu; Zhang, Manyu [Agilent Technologies China Co., Ltd, Shanghai 200080 (China); Guo, Yinlong, E-mail: ylguo@sioc.ac.cn [National Center for Organic Mass Spectrometry in Shanghai, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032 (China)

    2015-08-05

    A rapid method for fatty acids (FAs) comparative profiling based on carboxyl-specific stable isotope labeling (SIL) and direct infusion electrospray ionization–ion mobility–mass spectrometry (ESI–IM–MS) is established. The design of the method takes advantage of the three-dimensional characteristics of IM–MS including drift time, m/z and ion intensity, for comparison of d0-/d6-2,4-dimethoxy-6-piperazin-1-yl pyrimidine (DMPP)-labeled FAs. In particular, without chromatographic separation, the method allowed direct FAs profiling in complex samples due to the advantageous priority of DMPP in signal enhancement as well as the extra resolution that IM–MS offered. Additionally, the d0-/d6-DMPP-labeled FAs showed expected features, including very similar drift times, 6 Da mass deviations, specific reporter ions, similar MS responses, and adherence to the drift time rule regarding the influence of carbon chain length and unsaturation on relative drift times. Therefore, the introduction of isotope analogs minimized the matrix effect and variations in quantification and ensured accurate identification of non-targeted FAs by those typical features. Peak intensity ratios between d0-/d6-DMPP-labeled ions were subsequently used in relative quantification for the detected FAs. The established strategy has been applied successfully in the rapid profiling of trace free FAs between normal and cancerous human thyroid tissues. Sixteen free FAs were found with the increased level with a statistically significant difference (p < 0.05) compared to the normal tissue samples. The integrated SIL technique and ESI–IM–MS are expected to serve as an alternative tool for high-throughput analysis of FAs in complex samples. - Highlights: • A novel method based on IM–MS and SIL was developed for FAs comparative profiling. • Without LC separation, the method allowed direct infusion profiling of FAs in complex samples. • Both of the efficiency and accuracy for FAs analyses

  18. Application of Beam Diagnostics for Intense Heavy Ion Beams at the GSI UNILAC

    CERN Document Server

    Barth, W; Glatz, J; Groening, L; Richter, S; Yaramishev, S

    2003-01-01

    With the new High Current Injector (HSI) of the GSI UNILAC the beam pulse intensity had been increased by approximately two orders of magnitudes. The HSI was mounted and commissioned in 1999; since this time the UNILAC serves as an injector for the synchrotron SIS, especially for high uranium intensities. Considering the high beam power of up to 1250 kW and the short stopping range for the UNILAC beam energies (≤12 MeV/u), accelerator components could be destroyed, even during a single beam pulse. All diagnostic elements had to be replaced preferably by non-destructive devices. The beam current is mainly measured by beam transformers instead of Faraday cups, beam positions are measured with segmented capacitive pick-ups and secondary beam monitors instead of profile harps. The 24 installed pick-ups are also used to measure intensities, widths and phase of the bunches, as well beam energies by evaluating pick-ups at different positions. The residual gas ionization monitors allow on-line measurements ...

  19. Clues From Pluto's Ions

    Science.gov (United States)

    Kohler, Susanna

    2016-05-01

    Nearly a year ago, in July 2015, the New Horizons spacecraft passed by the Pluto system. The wealth of data amassed from that flyby is still being analyzed including data from the Solar Wind Around Pluto (SWAP) instrument. Recent examination of this data has revealedinteresting new information about Plutos atmosphere and how the solar wind interacts with it.A Heavy Ion TailThe solar wind is a constant stream of charged particles released by the Sun at speeds of around 400 km/s (thats 1 million mph!). This wind travels out to the far reaches of the solar system, interacting with the bodies it encounters along the way.By modeling the SWAP detections, the authors determine the directions of the IMF that could produce the heavy ions detected. Red pixels represent IMF directions permitted. No possible IMF could reproduce the detections if the ions are nitrogen (bottom panels), and only retrograde IMF directions can produce the detections if the ions are methane. [Adapted from Zirnstein et al. 2016]New Horizons data has revealed that Plutos atmosphere leaks neutral nitrogen, methane, and carbon monoxide molecules that sometimes escape its weak gravitational pull. These molecules become ionized and are subsequently picked up by the passing solar wind, forming a tail of heavy ions behind Pluto. The details of the geometry and composition of this tail, however, had not yet been determined.Escaping MethaneIn a recent study led by Eric Zirnstein (Southwest Research Institute), the latest analysis of data from the SWAP instrument on board New Horizons is reported. The team used SWAPs ion detections from just after New Horizons closest approach to Pluto to better understand how the heavy ions around Pluto behave, and how the solar wind interacts with Plutos atmosphere.In the process of analyzing the SWAP data, Zirnstein and collaborators first establish what the majority of the heavy ions picked up by the solar wind are. Models of the SWAP detections indicate they are unlikely

  20. Hydrolysis of VX on concrete: rate of degradation by direct surface interrogation using an ion trap secondary ion mass spectrometer.

    Science.gov (United States)

    Groenewold, Gary S; Williams, John M; Appelhans, Anthony D; Gresham, Garold L; Olson, John E; Jeffery, Mark T; Rowland, Brad

    2002-11-15

    The nerve agent VX (O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate) is lethal at very low levels of exposure, which can occur by dermal contact with contaminated surfaces. Hence, behavior of VX in contact with common urban or industrial surfaces is a subject of acute interest. In the present study, VX was found to undergo complete degradation when in contact with concrete surfaces. The degradation was directly interrogated at submonolayer concentrations by periodically performing secondary ion mass spectrometry (SIMS) analyses after exposure of the concrete to VX. The abundance of the [VX + H]+ ion in the SIMS spectra was observed to decrease in an exponential fashion, consistent with first-order or pseudo-first-order behavior. This phenomenon enabled the rate constant to be determined at 0.005 min(-1) at 25 degrees C, which corresponds to a half-life of about 3 h on the concrete surface. The decrease in [VX + H]+ was accompanied by an increase in the abundance of the principal degradation product diisopropylaminoethanethiol (DESH), which arises by cleavage of the P-S bond. Degradation to form DESH is accompanied by the formation of ethyl methylphosphonic acid, which is observable only in the negative ion spectrum. A second degradation product was also implicated, which corresponded to a diisopropylvinylamine isomer (perhaps N,N-diisopropyl aziridinium) that arose via cleavage of the S-C bond. No evidence was observed for the formation of the toxic S-2-diisopropylaminoethyl methylphosphonothioic acid. The degradation rate constants were measured at four different temperatures (24-50 degrees C), which resulted in a linear Arrhenius relationship and an activation energy of 52 kJ mol(-1). This value agrees with previous values observed for VX hydrolysis in alkaline solutions, which suggests that the degradation of submonolayer VX is dominated by alkaline hydrolysis within the adventitious water film on the concrete surface.

  1. Direct observation and mechanism for enhanced field emission sites in platinum ion implanted/post-annealed ultrananocrystalline diamond films

    Energy Technology Data Exchange (ETDEWEB)

    Panda, Kalpataru, E-mail: panda@afm.eei.eng.osaka-u.ac.jp, E-mail: phy.kalpa@gmail.com; Inami, Eiichi; Sugimoto, Yoshiaki [Graduate School of Engineering, Osaka University, 2-1, Yamada-Oka, Suita, Osaka 565-0871 (Japan); Sankaran, Kamatchi J.; Tai, Nyan Hwa [Department of Materials Science and Engineering, National Tsing Hua University, Hsinchu 30013, Taiwan (China); Lin, I-Nan, E-mail: inanlin@mail.tku.edu.tw [Department of Physics, Tamkang University, Tamsui 251, Taiwan (China)

    2014-10-20

    Enhanced electron field emission (EFE) properties for ultrananocrystalline diamond (UNCD) films upon platinum (Pt) ion implantation and subsequent post-annealing processes is reported, viz., low turn-on field of 4.17 V/μm with high EFE current density of 5.08 mA/cm{sup 2} at an applied field of 7.0 V/μm. Current imaging tunneling spectroscopy (CITS) mode in scanning tunneling spectroscopy directly revealed the increased electron emission sites density for Pt ion implanted/post-annealed UNCD films than the pristine one. The high resolution CITS mapping and local current–voltage characteristic curves demonstrated that the electrons are dominantly emitted from the diamond grain boundaries and Pt nanoparticles.

  2. Direct observation and mechanism for enhanced field emission sites in platinum ion implanted/post-annealed ultrananocrystalline diamond films

    International Nuclear Information System (INIS)

    Panda, Kalpataru; Inami, Eiichi; Sugimoto, Yoshiaki; Sankaran, Kamatchi J.; Tai, Nyan Hwa; Lin, I-Nan

    2014-01-01

    Enhanced electron field emission (EFE) properties for ultrananocrystalline diamond (UNCD) films upon platinum (Pt) ion implantation and subsequent post-annealing processes is reported, viz., low turn-on field of 4.17 V/μm with high EFE current density of 5.08 mA/cm 2 at an applied field of 7.0 V/μm. Current imaging tunneling spectroscopy (CITS) mode in scanning tunneling spectroscopy directly revealed the increased electron emission sites density for Pt ion implanted/post-annealed UNCD films than the pristine one. The high resolution CITS mapping and local current–voltage characteristic curves demonstrated that the electrons are dominantly emitted from the diamond grain boundaries and Pt nanoparticles.

  3. Ion structure and sequence of ion formation in acetylene flames

    Energy Technology Data Exchange (ETDEWEB)

    Larionova, I.A.; Fialkov, B.S.; Kalinich, K.YA.; Fialkov, A.B.; Ospanov, B.S.

    1993-06-01

    Results of a study of the ion composition of acetylene-air flames burning at low pressures are reported. Data on ion formation are compared for flames of saturated hydrocarbons, oxygen-containing fuels, and acetylene. It is shown that the characteristics of ion formation in the flame front and directly ahead of it are similar to those observed in flames of other fuels. These characteristics, however, are different in the low-temperature region. 9 refs.

  4. In-Source Laser Spectroscopy with the Laser Ion Source and Trap: First Direct Study of the Ground-State Properties of ^{217,219}Po

    Directory of Open Access Journals (Sweden)

    D. A. Fink

    2015-02-01

    Full Text Available A Laser Ion Source and Trap (LIST for a thick-target, isotope-separation on-line facility has been implemented at CERN ISOLDE for the production of pure, laser-ionized, radioactive ion beams. It offers two modes of operation, either as an ion guide, which performs similarly to the standard ISOLDE resonance ionization laser ion source (RILIS, or as a more selective ion source, where surface-ionized ions from the hot ion-source cavity are repelled by an electrode, while laser ionization is done within a radio-frequency quadrupole ion guide. The first physics application of the LIST enables the suppression of francium contamination in ion beams of neutron-rich polonium isotopes at ISOLDE by more than 1000 with a reduction in laser-ionization efficiency of only 20. Resonance ionization spectroscopy is performed directly inside the LIST device, allowing the study of the hyperfine structure and isotope shift of ^{217}Po for the first time. Nuclear decay spectroscopy of ^{219}Po is performed for the first time, revealing its half-life, α-to-β-decay branching ratio, and α-particle energy. This experiment demonstrates the applicability of the LIST at radioactive ion-beam facilities for the production and study of pure beams of exotic isotopes.

  5. Directed Flow in Heavy-Ion Collisions and Its Implications for Astrophysics

    Directory of Open Access Journals (Sweden)

    Yuri B. Ivanov

    2017-11-01

    Full Text Available Analysis of directed flow ( v 1 of protons, antiprotons and pions in heavy-ion collisions is performed in the range of collision energies s N N = 2.7–39 GeV. Simulations have been done within a three-fluid model employing a purely hadronic equation of state (EoS and two versions of the EoS with deconfinement transitions: a first-order phase transition and a smooth crossover transition. The crossover EoS is unambiguously preferable for the description of experimental data at lower collision energies s N N ≲ 20 Gev. However, at higher collision energies s N N ≳ 20 Gev. the purely hadronic EoS again becomes advantageous. This indicates that the deconfinement EoS in the quark-gluon sector should be stiffer at high baryon densities than those used in the calculation. The latter finding is in agreement with that discussed in astrophysics in connection with existence of hybrid stars with masses up to about two solar masses.

  6. Ion-acoustic waves and drift waves in negative ion sources

    International Nuclear Information System (INIS)

    Gerwin, R.A.

    1989-01-01

    Attention is directed towards instabilities induced in hydrogen plasmas due to the presence of the desired H/sup /minus// ions. Preliminary investigations indicate that when the electron temperature exceeds the temperature of the background ions (H + ), the H/sup /minus// beam causes collective instabilities even at very low (even vanishing) beam velocities, provided that the non-ideal properties of the background plasma are taken into consideration. The most dangerous instabilities involve oscillations transverse to the direction of beam extraction, and may thereby degrade the beam emittance. 5 refs

  7. NOVEL POLY-GLUTAMIC ACID FUNCTIONALIZED MICROFILTRATION MEMBRANES FOR SORPTION OF HEAVY METALS AT HIGH CAPACITY

    Science.gov (United States)

    Various sorbent/ion exchange materials have been reported in the literature for metal ion entrapment. We have developed a highly innovative and new approach to obtain high metal pick-up utilizing poly-amino acids (poly-L-glutamic acid, 14,000 MW) covalently attached to membrane p...

  8. Collaborative Research: A Model of Partially Ionized Plasma Flows with Kinetic Treatment of Neutral Atoms and Nonthermal Ions

    International Nuclear Information System (INIS)

    Pogorelov, Nikolai; Zhang, Ming

    2016-01-01

    Interactions of flows of partially ionized, magnetized plasma are frequently accompanied by the presence of both thermal and non-thermal (pickup) ion components. Such interactions cannot be modeled using traditional MHD equations and require more advanced approaches to treat them. If a nonthermal component of ions is formed due to charge exchange and collisions between the thermal (core) ions and neutrals, it experiences the action of magnetic field, its distribution function is isotropized, and it soon acquires the velocity of the ambient plasma without being thermodynamically equilibrated. This situation, e. g., takes place in the outer heliosphere -- the part of interstellar space beyond the solar system whose properties are determined by the solar wind interaction with the local interstellar medium. This is also possible in laboratory, at million degrees and above, when plasma is conducting electricity far too well, which makes Ohmic heating ineffective. To attain the target temperatures one needs additional heating eventually playing a dominant role. Among such sources is a so-called neutral particle beam heating. This is a wide-spread technique (Joint European Torus and International Thermonuclear Experimental Reactor experiments) based on the injection of powerful beams of neutral atoms into ohmically preheated plasma. In this project we have investigated the energy and density separation between the thermal and nonthermal components in the solar wind and interstellar plasmas. A new model has been developed in which we solve the ideal MHD equations for mixture of all ions and the kinetic Boltzmann equation to describe the transport of neutral atoms. As a separate capability, we can treat the flow of neutral atoms in a multi-component fashion, where neutral atoms born in each thermodynamically distinct region are governed by the Euler gas dynamic equations. We also describe the behavior of pickup ions either kinetically, using the Fokker--Planck equation, or

  9. Collaborative Research: A Model of Partially Ionized Plasma Flows with Kinetic Treatment of Neutral Atoms and Nonthermal Ions

    Energy Technology Data Exchange (ETDEWEB)

    Pogorelov, Nikolai [Univ. of Alabama, Huntsville, AL (United States); Zhang, Ming [Florida Inst. of Technology, Melbourne, FL (United States)

    2016-07-31

    Interactions of flows of partially ionized, magnetized plasma are frequently accompanied by the presence of both thermal and non-thermal (pickup) ion components. Such interactions cannot be modeled using traditional MHD equations and require more advanced approaches to treat them. If a nonthermal component of ions is formed due to charge exchange and collisions between the thermal (core) ions and neutrals, it experiences the action of magnetic field, its distribution function is isotropized, and it soon acquires the velocity of the ambient plasma without being thermodynamically equilibrated. This situation, e. g., takes place in the outer heliosphere –- the part of interstellar space beyond the solar system whose properties are determined by the solar wind interaction with the local interstellar medium. This is also possible in laboratory, at million degrees and above, when plasma is conducting electricity far too well, which makes Ohmic heating ineffective. To attain the target temperatures one needs additional heating eventually playing a dominant role. Among such sources is a so-called neutral particle beam heating. This is a wide-spread technique (Joint European Torus and International Thermonuclear Experimental Reactor experiments) based on the injection of powerful beams of neutral atoms into ohmically preheated plasma. In this project we have investigated the energy and density separation between the thermal and nonthermal components in the solar wind and interstellar plasmas. A new model has been developed in which we solve the ideal MHD equations for mixture of all ions and the kinetic Boltzmann equation to describe the transport of neutral atoms. As a separate capability, we can treat the flow of neutral atoms in a multi-component fashion, where neutral atoms born in each thermodynamically distinct region are governed by the Euler gas dynamic equations. We also describe the behavior of pickup ions either kinetically, using the Fokker--Planck equation

  10. Collaborative Research: A Model of Partially Ionized Plasma Flows with Kinetic Treatment of Neutral Atoms and Nonthermal Ions

    Energy Technology Data Exchange (ETDEWEB)

    Pogorelov, Nikolai [Univ. of Alabama, Huntsville, AL (United States). Dept. of Space Science. Center for Space Plasma and; Zhang, Ming [Florida Inst. of Technology, Melbourne, FL (United States). Physics and Space Sciences Dept.; Borovikov, Sergey [Univ. of Alabama, Huntsville, AL (United States). Dept. of Space Science. Center for Space Plasma and Aeronomic Research; Heerikhuisen, Jacob [Univ. of Alabama, Huntsville, AL (United States). Dept. of Space Science. Center for Space Plasma and Aeronomic Research; Zank, Gary [Univ. of Alabama, Huntsville, AL (United States). Dept. of Space Science. Center for Space Plasma and Aeronomic Research; Gamayunov, Konstantin [Florida Inst. of Technology, Melbourne, FL (United States). Physics and Space Sciences Dept.; Colella, Phillip [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2016-07-31

    Interactions of flows of partially ionized, magnetized plasma are frequently accompanied by the presence of both thermal and non-thermal (pickup) ion components. Such interactions cannot be modeled using traditional MHD equations and require more advanced approaches to treat them. If a nonthermal component of ions is formed due to charge exchange and collisions between the thermal (core) ions and neutrals, it experiences the action of magnetic field, its distribution function is isotropized, and it soon acquires the velocity of the ambient plasma without being thermodynamically equilibrated. This situation, e. g., takes place in the outer heliosphere - the part of interstellar space beyond the solar system whose properties are determined by the solar wind interaction with the local interstellar medium. This is also possible in laboratory, at million degrees and above, when plasma is conducting electricity far too well, which makes Ohmic heating ineffective. To attain the target temperatures one needs additional heating eventually playing a dominant role. Among such sources is a so-called neutral particle beam heating. This is a wide-spread technique (Joint European Torus and International Thermonuclear Experimental Reactor experiments) based on the injection of powerful beams of neutral atoms into ohmically preheated plasma. In this project we have investigated the energy and density separation between the thermal and nonthermal components in the solar wind and interstellar plasmas. A new model has been developed in which we solve the ideal MHD equations for mixture of all ions and the kinetic Boltzmann equation to describe the transport of neutral atoms. As a separate capability, we can treat the flow of neutral atoms in a multi-component fashion, where neutral atoms born in each thermodynamically distinct regions are governed by the Euler gas dynamic equations. We also describe the behavior of pickup ions either kinetically, using the Fokker–Planck equation, or

  11. Proton pickup from /sup 27/Al via the (n,d) reaction at 56. 3 MeV

    Energy Technology Data Exchange (ETDEWEB)

    Brady, F P; Shepard, J R; King, N S.P.; McNaughton, M W; Wang, J C [California Univ., Davis (USA)

    1977-09-26

    Energy spectra of deuterons from the /sup 27/Al(n,d)/sup 26/Mg reaction due to 56.3 MeV neutrons incident have been measured for 10/sup 0/ <= thetasub(c.m.) <= 55 /sup 0/. The angular distributions for the excitations observed at 0.0, 1.81, and 4.33 MeV are quite well described by DWBA calculations and yield spectroscopic factors in agreement with shell model calculations; but with calculations based on the rotational model, the agreement is less satisfactory particularly for the 4.33 MeV level. For the states at 7.86 and 9.16 MeV the fits, assuming p-shell pick-up, are only fair. Comparison with /sup 27/Al(d,/sup 3/He)/sup 26/Mg measurements shows that the deduced spectroscopic factors for the two reactions agree quite well.

  12. Possibilities for direct optical observation of negative hydrogen ions in ion beam plasma sources via Rayleigh or Thomson scattering

    International Nuclear Information System (INIS)

    Burgess, D.D.

    1985-01-01

    The possibilities of applying optical scattering techniques to the determination of H - concentrations in plasma sources relevant to negative ion beam generation are considered. Rayleigh scattering measurements for incident wavelengths just below the H - photoionization limit appear to be only just feasible experimentally. A more promising possibility is observation of the modification in a plasma containing negative ions of the collective ion-feature in Thomson scattering. Numerical predictions of the effects of H - concentration on the spectral distribution of the ion-feature are presented. (author)

  13. High current density ion source

    International Nuclear Information System (INIS)

    King, H.J.

    1977-01-01

    A high-current-density ion source with high total current is achieved by individually directing the beamlets from an electron bombardment ion source through screen and accelerator electrodes. The openings in these screen and accelerator electrodes are oriented and positioned to direct the individual beamlets substantially toward a focus point. 3 figures, 1 table

  14. Diffuse ions produced by electromagnetic ion beam instabilities

    International Nuclear Information System (INIS)

    Winske, D.; Leroy, M.M.

    1984-01-01

    The evolution of the electromagnetic ions beam instability driven by the reflected ion component backstreaming away from the earth's how shock into the foreshock region is studied by means computer simulation. The linear the quasi-linear states of the instability are found to be in good agreement with known results for the resonant model propagating parallel to the beam along the magnetic field and with theory developed in this paper for the nonresonant mode, which propagates antiparallel to the beam direction. The quasi-linear stage, which produces large amplitude 8Bapprox.B, sinusoidal transverse waves and ''intermediate'' ion distribution, is terminated by a nonlinear phase in which strongly nonlinear, compressive waves and ''diffuse'' ion distributions are produced. Additional processes by which the diffuse ions are accelerated to observed high energies are not addressed. The results are discussed in terms of the ion distributions and hydromagnetic waves observed in the foreshock of the earth's bow shock and of interplanetary shocks

  15. Production of C, N, O, and Ne ions by pulsed ion source and acceleration of these ions in the cyclotron

    International Nuclear Information System (INIS)

    Nakajima, Hisao; Kohara, Shigeo; Kageyama, Tadashi; Kohno, Isao

    1977-01-01

    The heavy ion source, of electron bombarded hot cathode type, is usually operated by applying direct current for arc discharge. In order to accelerate Ne 6+ ion in the cyclotron, a pulsed operation of this source was attempted. Ne 6+ and O 6+ ions were accelerated successfully up to 160 MeV and more than 0.1 μA of these ion were extracted from the cyclotron. C 5+ , Ne 7+ and 22 Ne 6+ ions were also extracted with a modest intensity of beam. The intensity of C 4+ , N 4+ , N 5+ , and O 5+ ions was increased about ten times. (auth.)

  16. Direct Detection of the Ion Pair to Free Ions Transformation upon Complexation with an Ion Receptor in Non‐Polar Solvents by using Conductometry

    Science.gov (United States)

    Iseda, Kazuya

    2018-01-01

    Abstract In this study, we performed conductometry in various organic solvents to directly detect the transformation from tetrabutylammonium chloride (TBACl) ion‐pair salt to the free ions through complexation with meso‐octamethylcalix[4]pyrrole (CP), which is a well‐known receptor for chloride anions. In the presence of CP, the conductivity of TBACl increases in various non‐polar solvents, indicating that complexation with CP enhances the ionic dissociation of TBACl in such non‐polar solvents. In other words, CP recognizes chloride as an ion‐paired salt as well as a free anion in non‐polar solvents. Additionally, the TBA(CP–Cl) complex exhibited a considerably lower ion‐pairing constant (K ip) than TBACl in non‐polar solvents, resulting in enhanced conductivity. Based on these findings, we can conclude that complexation of an anion with a hydrophobic anion receptor will be useful for creating functional and stimuli‐responsive soft materials in organic solvents using coulombic forces. PMID:29610717

  17. Directly connected series coupled HTPEM fuel cell stacks to a Li-ion battery DC bus for a fuel cell electrical vehicle

    DEFF Research Database (Denmark)

    Andreasen, Søren Juhl; Ashworth, Leanne; Remón, Ian Natanael

    2008-01-01

    The work presented in this paper examines the use of pure hydrogen fuelled high temperature polymer electrolyte membrane (HTPEM) fuel cell stacks in an electrical car, charging a Li-ion battery pack. The car is equipped with two branches of two series coupled 1 kW fuel cell stacks which...... are connected directly parallel to the battery pack during operation. This enables efficient charging of the batteries for increased driving range. With no power electronics used, the fuel cell stacks follow the battery pack voltage, and charge the batteries passively. This saves the electrical and economical...... losses related to these components and their added system complexity. The new car battery pack consists of 23 Li-ion battery cells and the charging and discharging are monitored by a battery management system (BMS) which ensures safe operating conditions for the batteries. The direct connection...

  18. Characterizing Ion Flows Across a Dipolarization Front

    Science.gov (United States)

    Arnold, H.; Drake, J. F.; Swisdak, M.

    2017-12-01

    In light of the Magnetospheric Multiscale Mission (MMS) moving to study predominately symmetric magnetic reconnection in the Earth's magnetotail, it is of interest to investigate various methods for determining the relative location of the satellites with respect to the x line or a dipolarization front. We use a 2.5 dimensional PIC simulation to explore the dependence of various characteristics of a front, or flux bundle, on the width of the front in the dawn-dusk direction. In particular, we characterize the ion flow in the x-GSM direction across the front. We find a linear relationship between the width of a front, w, and the maximum velocity of the ion flow in the x-GSM direction, Vxi, for small widths: Vxi/VA=w/di*1/2*(mVA2)/Ti*Bz/Bxwhere m, VA, di, Ti, Bz, and Bx are the ion mass, upstream Alfven speed, ion inertial length, ion temperature, and magnetic fields in the z-GSM and x-GSM directions respectively. However, once the width reaches around 5 di, the relationship gradually approaches the well-known theoretical limit for ion flows, the upstream Alfven speed. Furthermore, we note that there is a reversal in the Hall magnetic field near the current sheet on the positive y-GSM side of the front. This reversal is most likely due to conservation of momentum in the y-GSM direction as the ions accelerate towards the x-GSM direction. This indicates that while the ions are primarily energized in the x-GSM direction by the front, they transfer energy to the electromagnetic fields in the y-GSM direction. The former energy transfer is greater than the latter, but the reversal of the Hall magnetic field drags the frozen-in electrons along with it outside of the front. These simulations should better able researchers to determine the relative location of a satellite crossing a dipolarization front.

  19. Trajectory separation of channeled ions in crystalline materials

    International Nuclear Information System (INIS)

    Temkin, Misha; Chakarov, Ivan; Webb, Roger

    2000-01-01

    Spatial distributions of ions implanted into crystals can be of a very complex shape with 'lobes' due to ions penetrating through open channels in several directions. This paper suggests an analytical model which represents such a distribution as a linear combination of 'random' distribution and one or more 'channeled' distributions. This study is focused on the algorithm of the separation of ion trajectories into several distributions. The first distribution includes those ions which have undergone predominantly random collisions. The other distributions include those ions which have undergone mainly 'weak' collisions and traveled mostly along the main channeling directions. Our binary collision approximation (BCA) simulator is used for generating and analyzing ion trajectories. The spatial moments can be extracted from each separated distribution. It is shown that 2D analytical distributions obtained as a linear combination of distributions derived from these moments and aligned along corresponding channeling direction are in a very good agreement with direct BCA calculations

  20. Measurements of Coulomb Cross Section for Production of Direct Electron-pairs by High Energy Ions at the CERN SPS

    CERN Multimedia

    2002-01-01

    QED predicts copious direct electron pair production by ultrarelativistic heavy nuclei in a high Z medium such as nuclear emulsion. First order QED calculations (combined screening and non-screening) for this process show that 1000@+32 electron pairs above 100~keV energy) should be emitted for a total |1|6O track length of 10.9~m in nuclear emulsion at 200~GeV/AMU. Emulsion exposures with oxygen (and other nuclei if available) at 60 and 200~GeV/AMU will be used to calibrate the energy dependent cross section @s~@j~(1n~E)|2|-|3, whose exponent depends on atomic screening. The oxygen tracks in the developed emulsions will be scanned with a microscope, and the number of direct electron pairs will be counted for individual tracks. The exposed stacks will contain sufficient emulsion (and CR39 plastic to check for possible interactions) that adequate path length will be available for exposures to @$>$~10|4~ions at each energy and ion species. \\\\ \\\\ If the absolute value of this cross section is confirmed as large a...

  1. Gaseous odd- and even-electron ions

    International Nuclear Information System (INIS)

    Wagner, W.; Heimbach, H.; Levsen, K.

    1980-01-01

    The principal collision-induced fragmentations of simple protonated ketones, aldehydes, ethers, amines, sulphides, alcohols, acids, nitriles and halides are discussed. These protonated molecules decompose mainly by loss of alkane, alkene and RX (R = alkyl, H; X = OH, SH, NH 2 , Br, I). Substantial radical losses are only observed for small protonated molecules. Deuterium-labelling demonstrates that the X-H bond is particularly strong. The fragmentation of (MH) + ions is compared with that of the corresponding (M) + sup(.) ions is compared with that of the corresponding (M) + sup(.) ions. The spectra of the (M) + sup(.) ions are dominated by direct bond cleavages, in particular α-cleavages, as a result of both the stability of the ionic fragment and the loose transition state. In (MH) + ions direct bond cleavages lead to energetically less favourable products. Thus rearrangement reactions play a more important role in the decomposition of these ions. (MH) + ions are more stable relative to fragmentation than (M) + sup(.) ions. (orig.)

  2. The Heavy Ion Sensor (HIS) Onboard Solar Orbiter (SOLO): Calibration Results and Science Outlook

    Science.gov (United States)

    Livi, S. A.; Lepri, S. T.; Raines, J. M.; Galvin, A.; Kistler, L. M.; Allegrini, F.; Ogasawara, K.; Collier, M. R.

    2017-12-01

    The HIS sensor has been designed and optimized to study heavy ions in the solar wind, suprathermal particles, and pickup ions in the range 0.5 to 75keV/e. This instrument will allow for unprecedented data collection of particle characteristics near the Sun at various heliolatitudes during both the quiet and active phases of the solar cycle. The close proximity and the quasi-corotation will allow for determination of the source regions on the sun for the observed events. As a result of the measurements HIS will take, we will be able to: link events on the surface of the Sun with structures in the interplanetary medium; determine the extent of gravitational settling in the expansion region of the solar wind; identify interplanetary shocks and characterize their spatial and temporal evolution; characterize the power spectra of density and velocity uctuations upstream and downstream of shocks; study the heating and dissipation mechanisms at shocks at various radial distances and latitudes; and identify the mechanisms that heat thermal solar wind ions near shocks and determine the energy partition at shocks. During the course of 2016 and 2017 HIS has been calibrated at the facility of SwRI and University of Bern, using a large energy range (0.1-450 keV), multiple masses (H-Fe), as well as charge states (1-6). The results show that HIS will meet or exceed all necessary requirements to fullfill its ambitious scientific goals.

  3. Laparoscopic ovum pick-up in spotted paca ( Cuniculus pacas

    Directory of Open Access Journals (Sweden)

    F.F.P.C. Barros

    2016-08-01

    Full Text Available ABSTRACT The aim of this work is study the laparoscopic ovum pick-up (LapOPU technique in spotted paca, describing surgery details, complications and oocyte recovery rate. Nine healthy adult non-pregnant captive females were used, in a total of 39 procedures. When the surgical plane of anaesthesia was achieved, the females were positioned at 20º Trendelenburg. Three 6mm trocars were placed on right and left inguinal and hypogastric regions. Abdomen was inflated with CO2 and the intra-abdominal pressure was stablished in 10mmHg. Follicular punctures were performed moving the ovaries with atraumatic forceps. For punctures, an 18-gauge 3.5 inch long needle attached to a vacuum system with pressure not exceeding 65mmHg was used. Oocytes were recovered into 50mL centrifuge tubes with media composed of PBS supplemented with 10 IU/mL of heparin and kept at 36°C. R Software was used for statistical analysis. Data normality distribution (Shapiro test and variances homoscedasticity (Bartlett test were tested and descriptive statistics (mean±SD was used to present the results. It was only possible to perform LapOPU in 30 of 39 laparoscopies (76.92%. The surgical total time was 37.34 ± 18.53 minutes. The total number of visualized follicles, aspirated follicles, and retrieved oocytes were 502, 415, and 155, respectively. And the same parameters per animal were: 14.34 ± 12.23, 11.86 ± 10.03, and 4.43 ± 4.69 respectively. Oocyte recovery rate was 32.56 ± 27.32%. In conclusion, caudal positioning of portals with slight triangulation allows good viewing of the abdominal cavity and eases the manipulation of the ovaries. Thus this described LapOPU technique is feasible in spotted paca and easy to perform.

  4. Lithium-ion batteries

    CERN Document Server

    Yoshio, Masaki; Kozawa, Akiya

    2010-01-01

    This book is a compilation of up-to-date information relative to Li-Ion technology. It provides the reader with a single source covering all important aspects of Li-Ion battery operations. It fills the gap between the old original Li-Ion technology and present state of the technology that has developed into a high state of practice. The book is designed to provide a single source for an up-to-date description of the technology associated with the Li-Ion battery industry. It will be useful to researchers interested in energy conversion for the direct conversion of chemical energy into electrica

  5. Ion trap device

    Science.gov (United States)

    Ibrahim, Yehia M.; Smith, Richard D.

    2016-01-26

    An ion trap device is disclosed. The device includes a series of electrodes that define an ion flow path. A radio frequency (RF) field is applied to the series of electrodes such that each electrode is phase shifted approximately 180 degrees from an adjacent electrode. A DC voltage is superimposed with the RF field to create a DC gradient to drive ions in the direction of the gradient. A second RF field or DC voltage is applied to selectively trap and release the ions from the device. Further, the device may be gridless and utilized at high pressure.

  6. Water cluster fragmentation probed by pickup experiments

    Czech Academy of Sciences Publication Activity Database

    Huang, Ch.; Kresin, V. V.; Pysanenko, Andriy; Fárník, Michal

    2016-01-01

    Roč. 145, č. 10 (2016), s. 104304 ISSN 0021-9606 R&D Projects: GA ČR(CZ) GA15-12386S Institutional support: RVO:61388955 Keywords : Impact ionization * ions * mass spectroscopy Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.965, year: 2016

  7. Ion microprobes

    International Nuclear Information System (INIS)

    Coles, J.N.; Long, J.V.P.

    1977-01-01

    An ion microprobe is described that has an ion extraction arrangement comprising two separate paths for ions and electrons diverging from a common point. A cone shaped or pyramidal guard electrode surrounds each path the apex angles being equal and coinciding with the said point. The guard electrodes are positioned to lie tangentially to each other and to a planar surface including the said point. An aperture is provided for the two paths at the apexes of both guard electrodes, and electrical connections between the guard electrodes enable the same potential to be applied to both guard electrodes. Means are provided for generating oppositely polarised electric fields within the guard electrodes, together with means for causing a focused ion beam to strike the common point without suffering astigmatism. The means for causing a focused ion beam to strike the said point includes an ion gun for directing an ion beam along one of the paths and means to provide an axial accelerating field there along. Optical viewing means are also provided. Existing designs enable only ions or electrons, but not both, to be extracted at any one time. (U.K.)

  8. Engineering of beam direct conversion for a 120-kV, 1-MW ion beam

    International Nuclear Information System (INIS)

    Barr, W.L.; Doggett, J.N.; Hamilton, G.W.; Kinney, J.D.; Moir, R.W.

    1977-01-01

    Practical systems for beam direct conversion are required to recover the energy from ion beams at high efficiency and at very high beam power densities in the environment of a high-power, neutral-injection system. Such an experiment is now in progress using a 120-kV beam with a maximum total current of 20 A. After neutralization, the H + component to be recovered will have a power of approximately 1MW. A system testing these concepts has been designed and tested at 15 kV, 2 kW in preparation for the full-power tests. The engineering problems involved in the full-power tests affect electron suppression, gas pumping, voltage holding, diagnostics, and measurement conditions. Planning for future experiments at higher power includes the use of cryopumping and electron suppression by a magnetic field rather than by an electrostatic field. Beam direct conversion for large fusion experiments and reactors will save millions of dollars in the cost of power supplies and electricity and will dispose of the charged beam under conditions that may mot be possible by other techniques

  9. Engineering of beam direct conversion for a 120-kV, 1-MW ion beam

    International Nuclear Information System (INIS)

    Barr, W.L.; Doggett, J.N.; Hamilton, G.W.; Kinney, J.D.; Moir, R.W.

    1977-01-01

    Practical systems for beam direct conversion are required to recover the energy from ion beams at high efficiency and at very high beam power densities in the environment of a high-power, neutral-injection system. Such an experiment is now in progress using a 120-kV beam with a maximum total current of 20 A. After neutralization, the H + component to be recovered will have a power of approximately 1 MW. A system testing these concepts has been designed and tested at 15 kV, 2 kW in preparation for the full-power tests. The engineering problems involved in the full-power tests affect electron suppression, gas pumping, voltage holding, diagnostics, and measurement conditions. Planning for future experiments at higher power includes the use of cryopumping and electron suppression by a magnetic field rather than by an electrostatic field. Beam direct conversion for large fusion experiments and reactors will save millions of dollars in the cost of power supplies and electricity and will dispose of the charged beam under conditions that may not be possible by other techniques

  10. Metal negative ion beam extraction from a radio frequency ion source

    Energy Technology Data Exchange (ETDEWEB)

    Kanda, S.; Yamada, N.; Kasuya, T.; Romero, C. F. P.; Wada, M.

    2015-04-08

    A metal ion source of magnetron magnetic field geometry has been designed and operated with a Cu hollow target. Radio frequency power at 13.56 MHz is directly supplied to the hollow target to maintain plasma discharge and induce self-bias to the target for sputtering. The extraction of positive and negative Cu ion beams have been tested. The ion beam current ratio of Cu{sup +} to Ar{sup +} has reached up to 140% when Ar was used as the discharge support gas. Cu{sup −} ion beam was observed at 50 W RF discharge power and at a higher Ar gas pressure in the ion source. Improvement of poor RF power matching and suppression of electron current is indispensable for a stable Cu{sup −} ion beam production from the source.

  11. Negative ion sources for tandem accelerator

    International Nuclear Information System (INIS)

    Minehara, Eisuke

    1980-08-01

    Four kinds of negative ion sources (direct extraction Duoplasmatron ion source, radial extraction Penniing ion source, lithium charge exchange ion source and Middleton-type sputter ion source) have been installed in the JAERI tandem accelerator. The ion sources can generate many negative ions ranging from Hydrogen to Uranium with the exception of Ne, Ar, Kr, Xe and Rn. Discussions presented in this report include mechanisms of negative ion formation, electron affinity and stability of negative ions, performance of the ion sources and materials used for negative ion production. Finally, the author will discuss difficult problems to be overcome in order to get any negative ion sufficiently. (author)

  12. Demonstration of direct energy recovery of full-energy ions at 40 keV on a PLT/ISX beam system

    International Nuclear Information System (INIS)

    Stirling, W.L.; Barber, G.C.; Dagenhart, W.K.

    1981-01-01

    Neutral beam injection systems that employ positive ion sources presently operate at energies of about 40 to 50 keV/nucleon at 60 A [Princeton Large Torus (PLT)] or 100 A [Princeton Divertor Experiment (PDX) or the Oak Ridge National Laboratory (ORNL) Impurities Study Experiment (ISX)] with about 60% conversion efficiency. However, the desire for multisecond beams in the 80-keV/nucleon energy range at approx. 10 MW/module has emphasized the need for technological advances in several areas. At such beam energies, as much as 75% of the initial beam energy is retained in the unneutralized ion components. As a result, two questions immediately come to mind: (1) how can one dispose of this energy; or better still, (2) how can one efficiently recover this energy. We have proposed and demonstrated a unique solution to this problem that not only removes the need for beam dumps but also returns from 50 to 80% of the energy contained in the full energy ion component directly and dynamically to the high voltage supply. In fact, the energy in the residual ion component is not expended. The tests were made on a PLT/ISX-type beam line at 40 keV/nucleon with about 800 kW and 0.1 s

  13. Heavy ion fusion half-year report, October 1, 1983-March 31, 1984

    International Nuclear Information System (INIS)

    1984-04-01

    Results from the Single Beam Transport Experiment (SBTE) showed that stable beam transport in a 41-period AG lattice with single-particle phase advance per period, sigma 0 + 60 0 , was possible with space-charge forces large enough to depress the phase-advance to sigma = 12 0 . We have since extended that result and have shown that depression from sigma 0 = 60 0 to sigma = 8 0 is still stable. Measurements of the Cs + ion beam attenuation in the SBTE at different gas pressures, taken together with the different lattice acceptances for singly and doubly-charged ions, have allowed us to measure both the electron pick-up and electron cross-sections for Cs + on nitrogen at 160 keV. A large effort is under way to arrive at a conceptual reference design for the Multiple Beam Experiment (MBE), so that final engineering design and prototyping can begin as soon as possible. The MBE design process has stimulated many detailed questions for the theory group and several important results have ensued. For instance, on the question of what magnitude of sextupole component could be tolerated in the lenses, computer simulation showed that, for a space-charge-dominated beam, a significant sextupole term had essentially no effect if the beam remained on axis, but led to intolerable emittance growth for the practical case of an off-axis beam

  14. Direct Analysis of Organic Compounds in Liquid Using a Miniature Photoionization Ion Trap Mass Spectrometer with Pulsed Carrier-Gas Capillary Inlet.

    Science.gov (United States)

    Lu, Xinqiong; Yu, Quan; Zhang, Qian; Ni, Kai; Qian, Xiang; Tang, Fei; Wang, Xiaohao

    2017-08-01

    A miniature ion trap mass spectrometer with capillary direct sampling and vacuum ultraviolet photoionization source was developed to conduct trace analysis of organic compounds in liquids. Self-aspiration sampling is available where the samples are drawn into the vacuum chamber through a capillary with an extremely low flow rate (less than 1 μL/min), which minimizes sample consumption in each analysis to tens of micrograms. A pulsed gas-assisted inlet was designed and optimized to promote sample transmission in the tube and facilitate the cooling of ions, thereby improving instrument sensitivity. A limit of detection of 2 ppb could be achieved for 2,4-dimethylaniline in a methanol solution. The sampling system described in the present study is specifically suitable for a miniature photoionization ion trap mass spectrometer that can perform rapid and online analysis for liquid samples. Graphical Abstract ᅟ.

  15. Ion emission microscope microanalyzer

    International Nuclear Information System (INIS)

    Cherepin, V.T.; Olckovsky, V.L.

    1977-01-01

    In the ion microanalyzer (microprobe) the object is exposed to the bombardment of a highly focused ion beam, the secondary ions emitted from the object being analyzed by means of a mass filter. In order to be able to control the position of an analysis synchronous to the local analysis of an object an ion-optical converter (electron image with a fluorescent screen) is placed behind the aperture diaphragm in the direction of the secondary ion beam. The converter allows to make visible in front of the mass filter a non-split ion image characterizing the surface of the surface investigated. Then a certain section may be selected for performing chemical and isotope analyses. (DG) [de

  16. Particle Discrimination Experiment for Direct Energy Conversion

    International Nuclear Information System (INIS)

    Yasaka, Y.; Kiriyama, Y.; Yamamoto, S.; Takeno, H.; Ishikawa, M.

    2005-01-01

    A direct energy conversion system designed for D- 3 He fusion reactor based on a field reversed configuration employs a venetian-blind type converter for thermal ions to produce DC power and a traveling wave type converter for fusion protons to produce RF power. It is therefore necessary to separate, discriminate, and guide the particle species. For this purpose, a cusp magnetic field is proposed, in which the electrons are deflected and guided along the field line to the line cusp, while the ions pass through the point cusp. A small-scale experimental device was used to study the basic characteristics of discrimination of electrons and ions in the cusp magnetic field. Ions separated from electrons are guided to an ion collector, which is operated as a one-stage direct energy converter. The conversion efficiency was measured for cases with different values of mean and spread of ion energy. These experiments successfully demonstrate direct energy conversion from plasma beams using particle discrimination by a cusp magnetic field

  17. A feasibility study on direct methanol fuel cells for laptop computers based on a cost comparison with lithium-ion batteries

    International Nuclear Information System (INIS)

    Wee, Jung-Ho

    2007-01-01

    This paper compares the total cost of direct methanol fuel cell (DMFC) and lithium (Li)-ion battery systems when applied as the power supply for laptop computers in the Korean environment. The average power output and operational time of the laptop computers were assumed to be 20 W and 3000 h, respectively. Considering the status of their technologies and with certain conditions assumed, the total costs were calculated to be US$140 for the Li-ion battery and US$362 for DMFC. The manufacturing costs of the DMFC and Li-ion battery systems were calculated to be $16.65 W -1 and $0.77 W h -1 , and the energy consumption costs to be $0.00051 W h -1 and $0.00032 W h -1 , respectively. The higher fuel consumption cost of the DMFC system was due to the methanol (MeOH) crossover loss. Therefore, the requirements for DMFCs to be able to compete with Li-ion batteries in terms of energy cost include reducing the crossover level to at an order magnitude of -9 and the MeOH price to under $0.5 kg -1 . Under these conditions, if the DMFC manufacturing cost could be reduced to $6.30 W -1 , then the DMFC system would become at least as competitive as the Li-ion battery system for powering laptop computers in Korea. (author)

  18. Plasma source ion implantation

    International Nuclear Information System (INIS)

    Conrad, J.R.; Forest, C.

    1986-01-01

    The authors' technique allows the ion implantation to be performed directly within the ion source at higher currents without ion beam extraction and transport. The potential benefits include greatly increased production rates (factors of 10-1000) and the ability to implant non-planar targets without rastering or shadowing. The technique eliminates the ion extractor grid set, beam raster equipment, drift space and target manipulator equipment. The target to be implanted is placed directly within the plasma source and is biased to a large negative potential so that plasma ions gain energy as they accelerate through the potential drop across the sheath that forms at the plasma boundary. Because the sheath surrounds the target on all sides, all surfaces of the target are implanted without the necessity to raster the beam or to rotate the target. The authors have succeeded in implanting nitrogen ions in a silicon target to the depths and concentrations required for surface treatment of materials like stainless steel and titanium alloys. They have performed ESCA measurements of the penetration depth profile of a silicon target that was biased to 30 kV in a nitrogen discharge plasma. Nitrogen ions were implanted to a depth of 700A at a peak concentration of 30% atomic. The measured profile is quite similar to a previously obtained profile in titanium targets with conventional techniques

  19. Direct formation of thin films and epitaxial overlayers at low temperatures using a low-energy (10-500 eV) ion beam deposition system

    International Nuclear Information System (INIS)

    Zuhr, R.A.; Alton, G.D.; Appleton, B.R.; Herbots, N.; Noggle, T.S.; Pennycook, S.J.

    1987-01-01

    A low-energy ion beam deposition system has been developed at Oak Ridge National Laboratory and has been applied successfully to the growth of epitaxial films at low temperatures for a number of different elements. The deposition system utilizes the ion source and optics of a commercial ion implantation accelerator. The 35 keV mass- and energy-analyzed ion beam from the accelerator is decelerated in a four-element electrostatic lens assembly to energies between 10 and 500 eV for direct deposition onto a target under UHV conditions. Current densities on the order of 10 μA/cm 2 are achieved with good uniformity over a 1.4 cm diameter spot. The completed films are characterized by Rutherford backscattering, ion channeling, cross-section transmission electron microscopy, and x-ray diffraction. The effects of substrate temperature, ion energy, and substrate cleaning have been studied. Epitaxial overlayers which show good minimum yields by ion channeling (3 to 4%) have been produced at temperatures as low as 375 0 C for Si on Si(100) and 250 0 C for Ge on Ge(100) at growth rates that exceed the solid-phase epitaxy rates at these temperatures by more than an order of magnitude

  20. Ambient mass spectrometry employing direct analysis in real time (DART) ion source for olive oil quality and authenticity assessment

    International Nuclear Information System (INIS)

    Vaclavik, Lukas; Cajka, Tomas; Hrbek, Vojtech; Hajslova, Jana

    2009-01-01

    A novel approach for the authentication of olive oil samples representing different quality grades has been developed. A new type of ion source, direct analysis in real time (DART), coupled to a high-resolution time-of-flight mass spectrometer (TOFMS) was employed for the comprehensive profiling of triacylglycerols (TAGs) and/or polar compounds extracted with a methanol-water mixture. The main parameters influencing the ionization efficiency of TAGs were the type of sample solvent, degree of sample dilution, ion beam temperature, and presence of a dopant (ammonia vapors). The ionization yield of polar compounds depended mainly on a content of water in the extract and ion beam temperature. Using DART-TOFMS, not only differentiation among extra virgin olive oil (EVOO), olive pomace oil (OPO) and olive oil (OO) could be easily achieved, but also EVOO adulteration with commonly used adulterant, hazelnut oil (HO), was feasible. Based on the linear discriminant analysis (LDA), the introduced method allowed detection of HO addition of 6 and 15% (v/v) when assessing DART-TOFMS mass profiles of polar compounds and TAGs, respectively.

  1. Ambient mass spectrometry employing direct analysis in real time (DART) ion source for olive oil quality and authenticity assessment

    Energy Technology Data Exchange (ETDEWEB)

    Vaclavik, Lukas; Cajka, Tomas; Hrbek, Vojtech [Institute of Chemical Technology Prague, Faculty of Food and Biochemical Technology, Department of Food Chemistry and Analysis, Technicka 5, 166 28 Prague 6 (Czech Republic); Hajslova, Jana, E-mail: jana.hajslova@vscht.cz [Institute of Chemical Technology Prague, Faculty of Food and Biochemical Technology, Department of Food Chemistry and Analysis, Technicka 5, 166 28 Prague 6 (Czech Republic)

    2009-07-10

    A novel approach for the authentication of olive oil samples representing different quality grades has been developed. A new type of ion source, direct analysis in real time (DART), coupled to a high-resolution time-of-flight mass spectrometer (TOFMS) was employed for the comprehensive profiling of triacylglycerols (TAGs) and/or polar compounds extracted with a methanol-water mixture. The main parameters influencing the ionization efficiency of TAGs were the type of sample solvent, degree of sample dilution, ion beam temperature, and presence of a dopant (ammonia vapors). The ionization yield of polar compounds depended mainly on a content of water in the extract and ion beam temperature. Using DART-TOFMS, not only differentiation among extra virgin olive oil (EVOO), olive pomace oil (OPO) and olive oil (OO) could be easily achieved, but also EVOO adulteration with commonly used adulterant, hazelnut oil (HO), was feasible. Based on the linear discriminant analysis (LDA), the introduced method allowed detection of HO addition of 6 and 15% (v/v) when assessing DART-TOFMS mass profiles of polar compounds and TAGs, respectively.

  2. TOPOLOGY FOR A DSP BASED BEAM CONTROL SYSTEM IN THE AGS BOOSTER

    International Nuclear Information System (INIS)

    DELONG, J.; BRENNAN, J.M.; HAYES, T.; LE, T.N.; SMITH, K.

    2003-01-01

    The AGS Booster supports beams of ions and protons with a wide range of energies on a pulse-by-pulse modulation basis. This requires an agile beam control system highly integrated with its controls. To implement this system digital techniques in the form of Digital Signal Processors, Direct Digital Synthesizers, digital receivers and high speed Analog to Digital Converters are used. Signals from the beam and cavity pick-ups, as well as measurements of magnetic field strength in the ring dipoles are processed in real time. To facilitate this a multi-processor topology with high bandwidth data links is being designed

  3. A Mutualism Quantum Genetic Algorithm to Optimize the Flow Shop Scheduling with Pickup and Delivery Considerations

    Directory of Open Access Journals (Sweden)

    Jinwei Gu

    2015-01-01

    Full Text Available A mutualism quantum genetic algorithm (MQGA is proposed for an integrated supply chain scheduling with the materials pickup, flow shop scheduling, and the finished products delivery. The objective is to minimize the makespan, that is, the arrival time of the last finished product to the customer. In MQGA, a new symbiosis strategy named mutualism is proposed to adjust the size of each population dynamically by regarding the mutual influence relation of the two subpopulations. A hybrid Q-bit coding method and a local speeding-up method are designed to increase the diversity of genes, and a checking routine is carried out to ensure the feasibility of each solution; that is, the total physical space of each delivery batch could not exceed the capacity of the vehicle. Compared with the modified genetic algorithm (MGA and the quantum-inspired genetic algorithm (QGA, the effectiveness and efficiency of the MQGA are validated by numerical experiments.

  4. Investigation of ion kinetic effects in direct-drive exploding-pusher implosions at the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Rosenberg, M. J., E-mail: mrosenbe@mit.edu; Zylstra, A. B.; Séguin, F. H.; Rinderknecht, H. G.; Frenje, J. A.; Gatu Johnson, M.; Sio, H.; Waugh, C. J.; Sinenian, N.; Li, C. K.; Petrasso, R. D. [Plasma Science and Fusion Center, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); McKenty, P. W.; Hohenberger, M.; Radha, P. B.; Delettrez, J. A.; Glebov, V. Yu.; Betti, R.; Goncharov, V. N.; Knauer, J. P.; Sangster, T. C. [Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States); and others

    2014-12-15

    Measurements of yield, ion temperature, areal density (ρR), shell convergence, and bang time have been obtained in shock-driven, D{sub 2} and D{sup 3}He gas-filled “exploding-pusher” inertial confinement fusion (ICF) implosions at the National Ignition Facility to assess the impact of ion kinetic effects. These measurements probed the shock convergence phase of ICF implosions, a critical stage in hot-spot ignition experiments. The data complement previous studies of kinetic effects in shock-driven implosions. Ion temperature and fuel ρR inferred from fusion-product spectroscopy are used to estimate the ion-ion mean free path in the gas. A trend of decreasing yields relative to the predictions of 2D DRACO hydrodynamics simulations with increasing Knudsen number (the ratio of ion-ion mean free path to minimum shell radius) suggests that ion kinetic effects are increasingly impacting the hot fuel region, in general agreement with previous results. The long mean free path conditions giving rise to ion kinetic effects in the gas are often prevalent during the shock phase of both exploding pushers and ablatively driven implosions, including ignition-relevant implosions.

  5. Comparisons between direct ion storage and thermoluminescence dosimetry individual monitoring systems, and internet reporting

    International Nuclear Information System (INIS)

    Kiuru, A.; Kahilainen, J.; Hyvoenen, H.; Vartiainen, E.

    2001-01-01

    A new electronic direct ion storage (DIS) dosemeter allows accumulated personal dose equivalent H p (d) at depths of 10 mm and 0.07 mm to be monitored in a few seconds by inserting the dosemeter into a local reader without deleting the accumulated dose. The DIS system meets general requirements on individual monitoring of hospital personnel using ionising radiation. It differs greatly from off-line thermoluminescence dosimetry systems and offers many additional benefits. The non-volatile reading takes only 5 s, is taken as often as needed, and the data are collected into a dose database, where background radiation is subtracted. Individual personnel doses are reported in Intranet as well as on the Internet at regular intervals to the National Regulatory Authorities. (author)

  6. Production of microbunched beams of very highly charged ions with an electron beam ion source

    International Nuclear Information System (INIS)

    Stoeckli, M.P.

    1998-01-01

    Electron beam ion sources produce very highly charged ions most efficiently in a batch mode as the confinement time can be directly optimized for the production of the desired charge state. If, after confinement, the voltage of the ion-confining downstream dam is lowered rapidly, all ions escape and form an ion beam pulse with a length of a few tens of μs. Raising the main trap voltage while maintaining a constant dam voltage in a open-quotes spill-over expulsionclose quotes reduces the energy spread of the expelled ions. The longer time periods of open-quotes slow-,close quotes open-quotes leaky batch mode-,close quotes and open-quotes direct current (dc) batch mode-close quotes expulsions allow for increasing the ion beam duty cycle. Combining the rapid expulsion with one of the latter methods allows for the expulsion of the ions of a single batch in many small microbunches with variable intervals, maintaining the low energy spread and the increased duty cycle of slow expulsions. Combining the open-quotes microbunchingclose quotes with open-quotes dc batch mode productionclose quotes and a multitrap operation will eventually allow for the production of equally intense ion bunches over a wide range of frequencies without any deadtime, and with minimal compromise on the most efficient production parameters. copyright 1998 American Institute of Physics

  7. Plasma ion sources and ion beam technology in microfabrications

    International Nuclear Information System (INIS)

    Ji, Lili

    2007-01-01

    For over decades, focused ion beam (FIB) has been playing a very important role in microscale technology and research, among which, semiconductor microfabrication is one of its biggest application area. As the dimensions of IC devices are scaled down, it has shown the need for new ion beam tools and new approaches to the fabrication of small-scale devices. In the meanwhile, nanotechnology has also deeply involved in material science research and bioresearch in recent years. The conventional FIB systems which utilize liquid gallium ion sources to achieve nanometer scale resolution can no longer meet the various requirements raised from such a wide application area such as low contamination, high throughput and so on. The drive towards controlling materials properties at nanometer length scales relies on the availability of efficient tools. In this thesis, three novel ion beam tools have been developed and investigated as the alternatives for the conventional FIB systems in some particular applications. An integrated focused ion beam (FIB) and scanning electron microscope (SEM) system has been developed for direct doping or surface modification. This new instrument employs a mini-RF driven plasma source to generate focused ion beam with various ion species, a FEI two-lens electron (2LE) column for SEM imaging, and a five-axis manipulator system for sample positioning. An all-electrostatic two-lens column has been designed to focus the ion beam extracted from the source. Based on the Munro ion optics simulation, beam spot sizes as small as 100 nm can be achieved at beam energies between 5 to 35 keV if a 5 (micro)m-diameter extraction aperture is used. Smaller beam spot sizes can be obtained with smaller apertures at sacrifice of some beam current. The FEI 2LE column, which utilizes Schottky emission, electrostatic focusing optics, and stacked-disk column construction, can provide high-resolution (as small as 20 nm) imaging capability, with fairly long working distance

  8. Model based optimization of driver-pickup separation for eddy current measurement of gap

    Science.gov (United States)

    Klein, G.; Morelli, J.; Krause, T. W.

    2018-04-01

    The fuel channels in CANDU® (CANada Deuterium Uranium) nuclear reactors consist of a pressure tube (PT) contained within a larger diameter calandria tube (CT). The separation between the tubes, known as the PT-CT gap, ensures PT hydride blisters, which could lead to potential cracking of the PT, do not develop. Therefore, accurate measurements are required to confirm that contact between PT and CT is not imminent. Gap measurement uses an eddy current probe. However this probe is sensitive to lift-off variations, which can adversely affect estimated gap. A validated analytical flat plate model of eddy current response to gap was used to examine the effect of driver-pickup spacing on lift-off and response to gap at a frequency of 4 kHz, which is used for in-reactor measurements. This model was compared against, and shown to have good agreement with, a COMSOL® finite element method (FEM) model. The optimum coil separation, which included the constraint of coil size, was found to be 11 mm, resulting in a phase response between lift-off and response to change in gap of 66°. This work demonstrates the advantages of using analytical models for optimizing coil designs for measurement of parameters that may negatively influence the outcome of an inspection measurement.

  9. Design of a PC Based Pressure Indicator Using Inductive Pick-up Type Transducer and Bourdon Tube Sensor

    Directory of Open Access Journals (Sweden)

    S. C. BERA

    2009-08-01

    Full Text Available Bourdon tube is a mechanical type pressure sensor and the bourdon gauge measures gauge pressure of a process pipe line or a process tank. But it is a local indicator and special costlier techniques are required to transmit the reading of bourdon gauge to a remote distance. In the present paper, a very simple inductive pick-up type technique has been developed to transmit the reading of bourdon gauge to a remote distance in the form of 1-5 Volt D.C. signal. This signal has been optically isolated to design a PC based pressure indicator using Labtech Note Book Pro software. The theoretical analysis of the whole technique has been presented in the paper. The instrument developed using this technique has been experimentally tested and the experimental results are reported in the paper. A good linearity and repeatability of the instrument has been observed.

  10. Demonstration of direct energy recovery of full energy ions at 40 keV on a PLT/ISX beam system

    International Nuclear Information System (INIS)

    Stirling, W.L.; Barber, G.C.; Dagenhart, W.K.

    1980-01-01

    The desire for multisecond beams in the 80-keV/nucleon energy range at 10 MW/module has emphasized the need for technological advances in several areas. At such beam energies, as much as 75% of the initial beam energy is retained in the unneutralized ion components. As a result, two questions immediately come to mind: how can one dispose of this energy; or better still, how can one efficiently recover this energy. The conventional way of treating such a problem is to deflect the ions out of the neutral beam and onto water-cooled plates or beam dumps. This method has worked satisfactorily for 40-keV/nucleon beams in excess of 1.5 MW and approx. 0.5 s. However, the power per unit area to be disposed of in the high power, multisecond beams mentioned above is beyond present-day technology. We have proposed and demonstrated a unique solution to this problem which not only removes the need for beam dumps but also returns from 50 to 80% of the energy contained in the full energy ion component directly and dynamically to the high voltage supply. In fact, the energy in the residual ion component is not expended. The tests were made on a PLT/ISX type beam line at 40 keV/nucleon of about 800 kW and 0.1 s

  11. 3D hybrid simulation of the Titan's plasma environment

    Science.gov (United States)

    Lipatov, Alexander; Sittler, Edward, Jr.; Hartle, Richard

    2007-11-01

    Titan plays an important role as a simulation laboratory for multiscale kinetic plasma processes which are key processes in space and laboratory plasmas. A development of multiscale combined numerical methods allows us to use more realistic plasma models at Titan. In this report, we describe a Particle-Ion--Fluid-Ion--Fluid--Electron method of kinetic ion-neutral simulation code. This method takes into account charge-exchange and photoionization processes. The model of atmosphere of Titan was based on a paper by Sittler, Hartle, Vinas et al., [2005]. The background ions H^+, O^+ and pickup ions H2^+, CH4^+ and N2^+ are described in a kinetic approximation, where the electrons are approximated as a fluid. In this report we study the coupling between background ions and pickup ions on the multiple space scales determined by the ion gyroradiis. The first results of such a simulation of the dynamics of ions near Titan are discussed in this report and compared with recent measurements made by the Cassini Plasma Spectrometer (CAPS, [Hartle, Sittler et al., 2006]). E C Sittler Jr., R E Hartle, A F Vinas, R E Johnson, H T Smith and I Mueller-Wodarg, J. Geophys. Res., 110, A09302, 2005.R E Hartle, E C Sittler, F M Neubauer, R E Johnson, et al., Planet. Space Sci., 54, 1211, 2006.

  12. MHD waves detected by ice at distances > 28 x 106 km from Comet Halley: Cometary or solar wind origin

    International Nuclear Information System (INIS)

    Tsurutani, B.T.; Brinca, A.L.; Smith, E.J.; Thorne, R.M.; Scarf, F.L.; Gosling, J.T.; Ipavich, F.M.

    1986-01-01

    Spectral analyses of the high resolution magnetic field data are employed to determine if there is evidence of cometary heavy ion pickup when ICE was closest to Halley, ∼28 x 10 6 km. No evidence is found for the presence of heavy ion cyclotron waves. However, from this search, two new wave modes are discovered in the solar wind: electromagnetic ion cyclotron waves and drift mirror mode waves. Both modes have scales of 10 to 60 s (1 to 6 T/sub p/) in the spacecraft frame. The possibility of wave generation by cometary hydrogen pickup is explored. Theoretical arguments and further experimental evidence indicates that cometary origin is improbable. The most likely source is plasma instabilities associated with solar wind stream-stream interactions. VLF electrostatic emissions are found to occur in field minima or at gradients of the drift mirror structures. Possible generation mechanisms of drift mirror mode waves, cyclotron waves and electrostatic waves are discussed

  13. Ion Mobility Mass Spectrometry Direct Isotope Abundance Analysis

    International Nuclear Information System (INIS)

    Manard, Manuel J.; Weeks, Stephan; Kyle, Kevin

    2010-01-01

    The nuclear forensics community is currently engaged in the analysis of illicit nuclear or radioactive material for the purposes of non-proliferations and attribution. One technique commonly employed for gathering nuclear forensics information is isotope analysis. At present, the state-of-the-art methodology for obtaining isotopic distributions is thermal ionization mass spectrometry (TIMS). Although TIMS is highly accurate at determining isotope distributions, the technique requires an elementally pure sample to perform the measurement. The required radiochemical separations give rise to sample preparation times that can be in excess of one to two weeks. Clearly, the nuclear forensics community is in need of instrumentation and methods that can expedite their decision making process in the event of a radiological release or nuclear detonation. Accordingly, we are developing instrumentation that couples a high resolution IM drift cell to the front end of a MS. The IM cell provides a means of separating ions based upon their collision cross-section and mass-to-charge ratio (m/z). Two analytes with the same m/z, but with different collision cross-sections (shapes) would exit the cell at different times, essentially enabling the cell to function in a similar manner to a gas chromatography (GC) column. Thus, molecular and atomic isobaric interferences can be effectively removed from the ion beam. The mobility selected chemical species could then be introduced to a MS for high-resolution mass analysis to generate isotopic distributions of the target analytes. The outcome would be an IM/MS system capable of accurately measuring isotopic distributions while concurrently eliminating isobaric interferences and laboratory radiochemical sample preparation. The overall objective of this project is developing instrumentation and methods to produce near real-time isotope distributions with a modular mass spectrometric system that performs the required gas-phase chemistry and

  14. Ion channeling

    International Nuclear Information System (INIS)

    Erramli, H.; Blondiaux, G.

    1994-01-01

    Channeling phenomenon was predicted, many years ago, by stark. The first channeling experiments were performed in 1963 by Davies and his coworkers. Parallely Robinson and Oen have investigated this process by simulating trajectories of ions in monocrystals. This technique has been combined with many methods like Rutherford Backscattering Spectrometry (R.B.S.), Particles Induced X-rays Emission (P.I.X.E) and online Nuclear Reaction (N.R.A.) to localize trace elements in the crystal or to determine crystalline quality. To use channeling for material characterization we need data about the stopping power of the incident particle in the channeled direction. The ratios of channeled to random stopping powers of silicon for irradiation in the direction have been investigated and compared to the available theoretical results. We describe few applications of ion channeling in the field of materials characterization. Special attention is given to ion channeling combined with Charged Particle Activation Analysis (C.P.A.A.) for studying the behaviour of oxygen atoms in Czochralski silicon lattices under the influence of internal gettering and in different gaseous atmospheres. Association between ion channeling and C.P.A.A was also utilised for studying the influence of the growing conditions on concentration and position of carbon atoms at trace levels in the MOVPE Ga sub (1-x) Al sub x lattice. 6 figs., 1 tab., 32 refs. (author)

  15. Sources and acceleration efficiencies for energetic particles in the heliosphere

    International Nuclear Information System (INIS)

    Kucharek, H; Moebius, E

    2006-01-01

    Shocks at solar wind stream interaction regions, coronal mass ejections and magnetospheric obstacles have long been known for their intimate link with particle acceleration. Much enhanced capabilities to determine mass and charge composition at interplanetary shocks with ACE and SOHO have enabled us to identify sources and acceleration processes for the energetic particles. Both solar wind and interstellar pickup ions are substantial sources for particle acceleration in corotating interaction regions and at coronal mass ejections driven shocks and that flare particles are re-accelerated. Suprathermal distributions, such as pickup ions and pre-existing flare populations are accelerated much more efficiently than particles out of the solar wind. Recent results of the termination shock crossing by Voyager I and the scientific goals of the upcoming IBEX mission will be discussed

  16. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  17. Direct trace analysis of metals and alloys in a quadrupole ion-trap mass spectrometer

    CERN Document Server

    Song, K S; Yang, M; Cha, H K; Lee, J M; Lee, G H

    1999-01-01

    An ion-trap mass spectrometer adopting a quadrupole ion-trap and laser ablation/ionization method was constructed. The developed system was tested for composition analysis of some metals (Cu, stainless), and alloys (hastalloy C, mumetal) by mass spectrometry. Samples were analyzed by using laser ablation from a sample probe tip followed by a mass analysis with the quadrupole ion-trap. The quadrupole ion-trap was modified to enable laser ablation by a XeCl excimer laser pulse that passed radially through the ring electrode. A mass scan of the produced ions was performed in the mass selective instability mode wherein trapped ions were successively detected by increasing the rf voltage through the ring electrode. Factors affecting the mass resolution, such as pressure of buffer gas and ablation laser power, are discussed.

  18. Development of Blue Laser Direct-Write Lithography System

    Directory of Open Access Journals (Sweden)

    Hao-Wen Chang

    2012-01-01

    Full Text Available The optical lithography system researched in this study adopted the laser direct-write lithography technology with nano-positioning stage by using retailing blue ray optical pickup head contained 405nm wavelength and 0.85 numerical aperture of focus lens as the system lighting source. The system employed a photodiode received the focusing error signal reflected by the glass substrate to identify specimen position and automatic focused control with voice coil motor. The pattern substrate was loaded on a nano-positioning stage; input pattern path automatically and collocate with inner program at the same time. This research has successfully developed a blue laser lithography process system. The single spot size can be narrowed down to 3.07 μm and the linewidth is 3.3μm, time of laser control can reach to 450 ns and the exposure pattern can be controlled by program as well.

  19. Bi-Directional Ion Emission from Massive Gold Cluster Impacts on Nanometric Carbon Foils.

    Science.gov (United States)

    Debord, J Daniel; Della-Negra, Serge; Fernandez-Lima, Francisco A; Verkhoturov, Stanislav V; Schweikert, Emile A

    2012-04-12

    Carbon cluster emission from thin carbon foils (5-40 nm) impacted by individual Au(n) (+q) cluster projectiles (95-125 qkeV, n/q = 3-200) reveals features regarding the energy deposition, projectile range, and projectile fate in matter as a function of the projectile characteristics. For the first time, the secondary ion emission from thin foils has been monitored simultaneously in both forward and backward emission directions. The projectile range and depth of emission were examined as a function of projectile size, energy, and target thickness. A key finding is that the massive cluster impact develops very differently from that of a small polyatomic projectile. The range of the 125 qkeV Au(100q) (+q) (q ≈ 4) projectile is estimated to be 20 nm (well beyond the range of an equal velocity Au(+)) and projectile disintegration occurs at the exit of even a 5 nm thick foil.

  20. Ion pairing in ionic liquids

    International Nuclear Information System (INIS)

    Kirchner, Barbara; Malberg, Friedrich; Firaha, Dzmitry S; Hollóczki, Oldamur

    2015-01-01

    In the present article we briefly review the extensive discussion in literature about the presence or absence of ion pair-like aggregates in ionic liquids. While some experimental studies point towards the presence of neutral subunits in ionic liquids, many other experiments cannot confirm or even contradict their existence. Ion pairs can be detected directly in the gas phase, but no direct method is available to observe such association behavior in the liquid, and the corresponding indirect experimental proofs are based on such assumptions as unity charges at the ions. However, we have shown by calculating ionic liquid clusters of different sizes that assuming unity charges for ILs is erroneous, because a substantial charge transfer is taking place between the ionic liquid ions that reduce their total charge. Considering these effects might establish a bridge between the contradicting experimental results on this matter. Beside these results, according to molecular dynamics simulations the lifetimes of ion–ion contacts and their joint motions are far too short to verify the existence of neutral units in these materials. (topical review)

  1. Control of colliding ion beams

    International Nuclear Information System (INIS)

    Salisbury, W.W.

    1985-01-01

    This invention relates to a method and system for enhancing the power-producing capability of a nuclear fusion reactor, and more specifically to methods and structure for enhancing the ion density in a directed particle fusion reactor. In accordance with the invention, oppositely directed ion beams constrained to helical paths pass through an annular reaction zone. The object is to produce fusion reactions due to collisions between the ion beams. The reaction zone is an annulus as between an inner-cylindrical electrode and an outer-cylindrical coaxial electrode. The beams are enhanced in ion density at spaced points along the paths by providing spline structures protruding from the walls of the electrodes into the reaction zone. This structure causes variations in the electric field along the paths followed by the ion beams. Such fields cause the beams to be successively more and less concentrated as the beams traverse the reaction zone. Points of high concentration are the points at which fusion-producing collisions are most likely to take place

  2. Dust ion-acoustic shock waves in magnetized pair-ion plasma with kappa distributed electrons

    Science.gov (United States)

    Kaur, B.; Singh, M.; Saini, N. S.

    2018-01-01

    We have performed a theoretical and numerical analysis of the three dimensional dynamics of nonlinear dust ion-acoustic shock waves (DIASWs) in a magnetized plasma, consisting of positive and negative ion fluids, kappa distributed electrons, immobile dust particulates along with positive and negative ion kinematic viscosity. By employing the reductive perturbation technique, we have derived the nonlinear Zakharov-Kuznetsov-Burgers (ZKB) equation, in which the nonlinear forces are balanced by dissipative forces (associated with kinematic viscosity). It is observed that the characteristics of DIASWs are significantly affected by superthermality of electrons, magnetic field strength, direction cosines, dust concentration, positive to negative ions mass ratio and viscosity of positive and negative ions.

  3. Direct evaluation of radiobiological parameters from clinical data in the case of ion beam therapy: an alternative approach to the relative biological effectiveness

    International Nuclear Information System (INIS)

    Cometto, A; Russo, G; Giordanengo, S; Marchetto, F; Cirio, R; Attili, A; Bourhaleb, F; Milian, F M

    2014-01-01

    The relative biological effectiveness (RBE) concept is commonly used in treatment planning for ion beam therapy. Whether models based on in vitro/in vivo RBE data can be used to predict human response to treatments is an open issue. In this work an alternative method, based on an effective radiobiological parameterization directly derived from clinical data, is presented. The method has been applied to the analysis of prostate cancer trials with protons and carbon ions. Prostate cancer trials with proton and carbon ion beams reporting 5 year-local control (LC5) and grade 2 (G2) or higher genitourinary toxicity rates (TOX) were selected from literature to test the method. Treatment simulations were performed on a representative subset of patients to produce dose and linear energy transfer distribution, which were used as explicative physical variables for the radiobiological modelling. Two models were taken into consideration: the microdosimetric kinetic model (MKM) and a linear model (LM). The radiobiological parameters of the LM and MKM were obtained by coupling them with the tumor control probability and normal tissue complication probability models to fit the LC5 and TOX data through likelihood maximization. The model ranking was based on the Akaike information criterion. Results showed large confidence intervals due to the limited variety of available treatment schedules. RBE values, such as RBE = 1.1 for protons in the treated volume, were derived as a by-product of the method, showing a consistency with current approaches. Carbon ion RBE values were also derived, showing lower values than those assumed for the original treatment planning in the target region, whereas higher values were found in the bladder. Most importantly, this work shows the possibility to infer the radiobiological parametrization for proton and carbon ion treatment directly from clinical data. (paper)

  4. Heavy ion induced DNA transfer in biological cells

    International Nuclear Information System (INIS)

    Vilaithong, T.; Yu, L.D.; Apavatjrut, P.; Phanchaisri, B.; Sangyuenyongpipat, S.; Anuntalabhochai, S.; Brown, I.G.

    2004-01-01

    Low-energy ion beam bombardment of biological materials for genetic modification purposes has experienced rapid growth in the last decade, particularly for the direct DNA transfer into living organisms including both plants and bacteria. Attempts have been made to understand the mechanisms involved in ion-bombardment-induced direct gene transfer into biological cells. Here we summarize the present status of the application of low-energy ions for genetic modification of living sample materials

  5. Evolution of direct mechanisms with incident energy from the Coulomb-barrier to relativistic energies. - Two-center effects in nucleon transfer between nuclei. - Signatures of nucleon promotion in heavy ion reactions at barrier energies

    International Nuclear Information System (INIS)

    Oertzen, W. von; Voit, H.; Imanishi, B.

    1988-10-01

    This report contains a review article considering the evolution of direct mechanisms with incident energy in heavy ion reactions and two theoretical articles concerning two-center effects in transfer reactions between heavy ions and the nucleon promotion in heavy ion reactions. See hints under the relevant topics. (HSI)

  6. Direct measurement of the transition from edge to core power coupling in a light-ion helicon source

    Science.gov (United States)

    Piotrowicz, P. A.; Caneses, J. F.; Showers, M. A.; Green, D. L.; Goulding, R. H.; Caughman, J. B. O.; Biewer, T. M.; Rapp, J.; Ruzic, D. N.

    2018-05-01

    We present time-resolved measurements of an edge-to-core power transition in a light-ion (deuterium) helicon discharge in the form of infra-red camera imaging of a thin stainless steel target plate on the Proto-Material Exposure eXperiment device. The time-resolved images measure the two-dimensional distribution of power deposition in the helicon discharge. The discharge displays a mode transition characterized by a significant increase in the on-axis electron density and core power coupling, suppression of edge power coupling, and the formation of a fast-wave radial eigenmode. Although the self-consistent mechanism that drives this transition is not yet understood, the edge-to-core power transition displays characteristics that are consistent with the discharge entering a slow-wave anti-resonant regime. RF magnetic field measurements made across the plasma column, together with the power deposition results, provide direct evidence to support the suppression of the slow-wave in favor of core plasma production by the fast-wave in a light-ion helicon source.

  7. Medium-energy ion reflection from solids

    CERN Document Server

    Mashkova, ES

    1985-01-01

    ``Medium-Energy Ion Reflection from Solids'' analyses the results of experimental, theoretical and computer investigations on the process of scattering of ions by solid surfaces. Surface scattering is a relatively young and rapidly developing branch of the physics of atomic collisions and the literature on this subject has rapidly grown.As the first monograph devoted specifically to surface scattering of ions, this book is directed at scientists involved in ion-solid interaction studies.

  8. Observations of strong ion-ion correlations in dense plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Ma, T.; Fletcher, L.; Pak, A.; Chapman, D. A.; Falcone, R. W.; Fortmann, C.; Galtier, E.; Gericke, D. O.; Gregori, G.; Hastings, J.; Landen, O. L.; Le Pape, S.; Lee, H. J.; Nagler, B.; Neumayer, P.; Turnbull, D.; Vorberger, J.; White, T. G.; Wünsch, K.; Zastrau, U.; Glenzer, S. H.; Döppner, T.

    2014-05-01

    Using simultaneous spectrally, angularly, and temporally resolved x-ray scattering, we measure the pronounced ion-ion correlation peak in a strongly coupled plasma. Laser-driven shock-compressed aluminum at ~3× solid density is probed with high-energy photons at 17.9 keV created by molybdenum He-α emission in a laser-driven plasma source. The measured elastic scattering feature shows a well-pronounced correlation peak at a wave vector of k=4k=4Å-1. The magnitude of this correlation peak cannot be described by standard plasma theories employing a linear screened Coulomb potential. Advanced models, including a strong short-range repulsion due to the inner structure of the aluminum ions are however in good agreement with the scattering data. These studies have demonstrated a new highly accurate diagnostic technique to directly measure the state of compression and the ion-ion correlations. We have since applied this new method in single-shot wave-number resolved S(k) measurements to characterize the physical properties of dense plasmas.

  9. Fast-ion response to energetic-particle-driven MHD activity in Heliotron J

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, S.; Yamamoto, S.; Mizuuchi, T.; Nagasaki, K.; Okada, H.; Minami, T.; Hanatani, K.; Konoshima, S.; Ohshima, S.; Toushi, K.; Sano, F. [Institute of Advanced Energy, Kyoto University, Gokasho, Uji (Japan); Nagaoka, K.; Suzuki, Y.; Takeiri, Y.; Yokoyama, M. [National Institute for Fusion Science, Toki, Gifu (Japan); Murakami, S. [Graduate School of Engineering, Kyoto University, Kyoto (Japan); Lee, H.Y.; Nakamura, Y.; Hosaka, K. [Graduate School of Energy Science, Kyoto University, Gokasho, Uji (Japan)

    2010-08-15

    In Heliotron J, low magnetic shear configuration, instabilities with frequency chirping in the frequency range of Alfven eigenmodes have been observed in tangentially injected neutral beam plasmas. These modes are induced by energetic-particle driven magnetohydrodynamic (MHD) instabilities such as global Alfven eigenmode or energetic particle mode. A hybrid directional Langmuir probe system has been installed into Heliotron J to investigate the response of fast-ion fluxes to the MHD modes. A high coherent response of the ion flux to the bursting modes has been observed not only by the co-directed probe but also by the counter-directed one. A linear correlation between the response of the co-directed ion flux and the mode amplitude has been found. The radial profile of the response of the co-directed ions has decreased with the minor radius and has not been obtained significantly outside last closed flux surface. These results indicate that the fast-ion response is due to a resonant convective oscillation. The ion flux response of the counter-directed probe has appeared in the growth phase of the mode burst. Its phase relation is different from that of co-directed one and magnetic probe located at the Heliotron J vacuum vessel. Two candidates of the detected ion flux of the counter-directed probe have been discussed. (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Development of exploding wire ion source for intense pulsed heavy ion beam accelerator

    International Nuclear Information System (INIS)

    Ochiai, Y.; Murata, T.; Ito, H.; Masugata, K.

    2012-01-01

    A Novel exploding wire type ion source device is proposed as a metallic ion source of intense pulsed heavy ion beam (PHIB) accelerator. In the device multiple shot operations is realized without breaking the vacuum. The basic characteristics of the device are evaluated experimentally with an aluminum wire of diameter 0.2 mm, length 25 mm. Capacitor bank of capacitance 3 μF, charging voltage 30 kV was used and the wire was successfully exploded by a discharge current of 15 kA, rise time 5.3 μs. Plasma flux of ion current density around 70 A/cm 2 was obtained at 150 mm downstream from the device. The drift velocity of ions evaluated by a time-of-flight method was 2.7x10 4 m/sec, which corresponds to the kinetic energy of 100 eV for aluminum ions. From the measurement of ion current density distribution ion flow is found to be concentrated to the direction where ion acceleration gap is placed. From the experiment the device is found to be acceptable for applying PHIB accelerator. (author)

  11. Sputtering on cobalt with noble gas ions

    International Nuclear Information System (INIS)

    Sarholt-Kristensen, L.; Johansen, A.; Johnson, E.

    1983-01-01

    Single crystals of cobalt have been bombarded with 80 keV Ar + ions and with 80 keV and 200 keV Xe + ions in the [0001] direction of the hcp phase and the [111] direction of the fcc phase. The sputtering yield has been measured as function of target temperature (20 0 C-500 0 C), showing a reduction in sputtering yield for 80 keV Ar + ions and 200 keV Xe + ions, when the crystal structure changes from hcp to fcc. In contrast to this, bombardment with 80 keV Xe + ions results in an increase in sputtering yield as the phase transition is passed. Sputtering yields for [111] nickel are in agreement with the sputtering yields for fcc cobalt indicating normal behaviour of the fcc cobalt phase. The higher sputtering yield of [0001] cobalt for certain combinations of ion mass and energy may then be ascribed to disorder induced partly by martensitic phase transformation, partly by radiation damage. (orig.)

  12. Kinetic method of ruthenium ion traces determination, basing on the reaction of oxidation of direct blue 6B, by means of hydrogen peroxide

    International Nuclear Information System (INIS)

    Suwinska, T.; Gregorowicz, A.; Matysek-Majewska, D.

    1980-01-01

    A sensitive and selective method of determination of ruthenium ion traces (1.10 - 3 μg/cm 3 ) has been worked out. The method is based on oxidation of direct blue 6B by hydrogen peroxide under acidic conditions at pH = 0,8 - 1,2 in the presence of ruthenium ions as catalyst. The method has been applied for determination of ruthenium traces in Pt, PdCl 2 , PtCl 4 and RhCl 3 .n H 2 O. In these materials ruthenium has been determined within the range of 1,10 - 2 % - 5,10 - 4 %. (author)

  13. Direction for the Future - Successive Acceleration of Positive and Negative Ions Applied to Space Propulsion

    CERN Document Server

    Aanesland, A.; Popelier, L.; Chabert, P.

    2013-12-16

    Electrical space thrusters show important advantages for applications in outer space compared to chemical thrusters, as they allow a longer mission lifetime with lower weight and propellant consumption. Mature technologies on the market today accelerate positive ions to generate thrust. The ion beam is neutralized by electrons downstream, and this need for an additional neutralization system has some drawbacks related to stability, lifetime and total weight and power consumption. Many new concepts, to get rid of the neutralizer, have been proposed, and the PEGASES ion-ion thruster is one of them. This new thruster concept aims at accelerating both positive and negative ions to generate thrust, such that additional neutralization is redundant. This chapter gives an overview of the concept of electric propulsion and the state of the development of this new ion-ion thruster.

  14. Ship Routing with Pickup and Delivery for a Maritime Oil Transportation System: MIP Model and Heuristics

    Directory of Open Access Journals (Sweden)

    Vinícius P. Rodrigues

    2016-09-01

    Full Text Available This paper examines a ship routing problem with pickup and delivery and time windows for maritime oil transportation, motivated by the production and logistics activities of an oil company operating in the Brazilian coast. The transportation costs from offshore platforms to coastal terminals are an important issue in the search for operational excellence in the oil industry, involving operations that demand agile and effective decision support systems. This paper presents an optimization approach to address this problem, based on a mixed integer programming (MIP model and a novel and exploratory application of two tailor-made MIP heuristics, based on relax-and-fix and time decomposition procedures. The model minimizes fuel costs of a heterogeneous fleet of oil tankers and costs related to freighting contracts. The model also considers company-specific constraints for offshore oil transportation. Computational experiments based on the mathematical models and the related MIP heuristics are presented for a set of real data provided by the company, which confirm the potential of optimization-based methods to find good solutions for problems of moderate sizes.

  15. Ion implantation

    International Nuclear Information System (INIS)

    Johnson, E.

    1986-01-01

    It is the purpose of the present paper to give a review of surface alloy processing by ion implantation. However, rather than covering this vast subject as a whole, the survey is confined to a presentation of the microstructures that can be found in metal surfaces after ion implantation. The presentation is limited to alloys processed by ion implantation proper, that is to processes in which the alloy compositions are altered significantly by direct injection of the implanted ions. The review is introduced by a presentation of the processes taking place during development of the fundamental event in ion implantation - the collision cascade, followed by a summary of the various microstructures which can be formed after ion implantation into metals. This is compared with the variability of microstructures that can be achieved by rapid solidification processing. The microstructures are subsequently discussed in the light of the processes which, as the implantations proceed, take place during and immediately after formation of the individual collision cascades. These collision cascades define the volumes inside which individual ions are slowed down in the implanted targets. They are not only centres for vigorous agitation but also the sources for formation of excess concentrations of point defects, which will influence development of particular microstructures. A final section presents a selection of specific structures which have been observed in different alloy systems. (orig./GSCH)

  16. Development of C6+ laser ion source and RFQ linac for carbon ion radiotherapy

    Science.gov (United States)

    Sako, T.; Yamaguchi, A.; Sato, K.; Goto, A.; Iwai, T.; Nayuki, T.; Nemoto, K.; Kayama, T.; Takeuchi, T.

    2016-02-01

    A prototype C6+ injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4.

  17. Development of C6+ laser ion source and RFQ linac for carbon ion radiotherapy

    International Nuclear Information System (INIS)

    Sako, T.; Yamaguchi, A.; Sato, K.; Goto, A.; Iwai, T.; Nayuki, T.; Nemoto, K.; Kayama, T.; Takeuchi, T.

    2016-01-01

    A prototype C 6+ injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4

  18. A laser activated ion source

    International Nuclear Information System (INIS)

    Hughes, J.; Luther-Davies, B.; Hora, H.; Kelly, J.

    1978-01-01

    Apparatus for generating energetic ions of a target material from a cold plasma of the material is described. A pulsed laser beam is directed onto the target to produce the cold plasma. Laser beam pulses are short in relation to the collision time in the plasma. Non-linear elctrodynamic forces within the plasma act to accelerate and eject ions from the plasma. The apparatus can be used to separate ions of isotopes of an element

  19. Preparation of targets by ion implantation

    International Nuclear Information System (INIS)

    Santry, D.C.

    1976-01-01

    Various factors are described which are involved in target preparation by direct ion implantation and the limitations and pitfalls of the method are emphasized. Examples are given of experiments for which ion implanted targets are well suited. (author)

  20. Direct evidence for a thermal effect of Ar+ ion bombardment in a conventional sputtering mode

    International Nuclear Information System (INIS)

    Okuyama, F.; Fujimoto, Y.

    1986-01-01

    Evidence is presented that the Ar + ion bombardment for sputtering in Auger electron spectroscopy can heat the target up to 2000 0 C if the target has poor heat conduction. Polycrystalline microneedles of Cr exhibited spherical tips after being exposed to 3 keV Ar + ions, proving that the needle tips were melted by impacting Ar + ions. Microneedles of Mo ion bombarded under the same condition were bent plastically, which perhaps reflects the thermal annealing of the needles during ion bombardment

  1. Polarization phenomena in heavy-ion reactions

    International Nuclear Information System (INIS)

    Sugimoto, K.; Ishihara, M.; Takahashi, N.

    1984-01-01

    This chapter presents a few key experiments which provide direct evidence of the polarization phenomena in heavy-ion reactions. The theory of polarization observables and measurements is given with the necessary formulae. The polarization phenomena is described and studies of product nuclear polarization in heavy-ion reactions are discussed. Studies of heavy-ion reactions induced by polarized beams are examined

  2. Magnetic blocking direct-recovery efficiency

    International Nuclear Information System (INIS)

    Whealton, J.H.; Wooten, J.H.; McGaffey, R.W.

    1981-10-01

    The ion recovery efficiency of a transverse magnetic field monochromatic direct recovery device intended for intense neutral beams is examined theoretically by solving a Poisson-Vlasov equation. An optimum in recovery efficiency is obtained for finite ion current density and excess initial speed

  3. Critically safe volume vacuum pickup for use in wet or dry cleanup of radioactive enclosures

    International Nuclear Information System (INIS)

    Zeren, J.D.

    1993-01-01

    A physical compact vacuum pickup device of critically safe volume and geometric shape is provided for use in radioactive enclosures, such as a small glove box, to facilitate manual cleanup of either wet or dry radioactive material. The device is constructed and arranged so as to remain safe when filled to capacity with plutonium-239 oxide. Two fine mesh filter bags are supported on the exterior of a rigid fine mesh stainless steel cup. This assembly is sealed within, and spaced from, the interior walls of a stainless steel canister. An air inlet communicates with the interior of the canister. A modified conventional vacuum head is physically connected to, and associated with, the interior of the mesh cup. The volume of the canister, as defined by the space between the mesh cup and the interior walls of the canister, forms a critically safe volume and geometric shape for dry radioactive particles that are gathered within the canister. A critically safe liquid volume is maintained by operation of a suction terminating float valve, and/or by operation of redundant vacuum check/liquid drain valves and placement of the air inlet. 5 figures

  4. Description of heavy-ion fusion in terms of direct reaction theory

    International Nuclear Information System (INIS)

    Hong, S.W.

    1987-01-01

    A direct reaction description of the heavy-ion fusion, proposed by Udagawa, Kim and Tamura, has been successfully used in calculating the fusion cross sections and the spin distributions for a number of systems in the energy regions from the sub-barrier to the above-barrier region. A fusion potential is introduced in this theory and the radius of the fusion potential is treated as an adjustable parameter. The theory is thus a one-parameter theory. The results obtained by Udagawa, Kim and Tamura showed that the radius parameter ranges from 1.4 to 1.5 fm, which is much larger than the radius (1.0 fm) used in other models. A hard evidence is shown to demonstrate the necessity of the long-ranged fusion potential radius in the near-barrier region. In the above-barrier region, the use of the energy-dependent optical potential and the energy-dependent fusion potential radius is proved to be essential in reproducing the measured fusion cross sections. As a further application of the theory, the double folded potential model is utilized to provide the real part of the optical potential. The imaginary part of the optical potential is determined so that not only the elastic scattering but also the fusion cross sections can be reproduced

  5. Possible origin and roles of nano-porosity in ZrO2 scales for hydrogen pick-up in Zr alloys

    Science.gov (United States)

    Lindgren, Mikaela; Geers, Christine; Panas, Itai

    2017-08-01

    A mechanistic understanding of Wagnerian build-up and subsequent non-Wagnerian break-down of barrier oxide upon oxidation of zirconium alloys by water is reiterated. Hydrogen assisted build-up of nano-porosity is addressed. Growth of sub-nanometer wide stalactitic pores owing to increasing aggregation of neutral oxygen vacancies offering a means to permeate hydrogen into the alloy is explored by density functional theory. The Wagnerian channel utilizes charge separation allowing charged oxygen vacancies and electrons to move separately from nominal anode to nominal cathode. This process becomes increasingly controlled by the charging of the barrier oxide resulting in sub-parabolic rate law for oxide growth. The break-down of the barrier oxide is understood to be preceded by avalanching hydrogen pick-up in the alloy. Pore mediated diffusion allows water to effectively short circuit the barrier oxide.

  6. Ion-Molecule Reaction Dynamics.

    Science.gov (United States)

    Meyer, Jennifer; Wester, Roland

    2017-05-05

    We review the recent advances in the investigation of the dynamics of ion-molecule reactions. During the past decade, the combination of single-collision experiments in crossed ion and neutral beams with the velocity map ion imaging detection technique has enabled a wealth of studies on ion-molecule reactions. These methods, in combination with chemical dynamics simulations, have uncovered new and unexpected reaction mechanisms, such as the roundabout mechanism and the subtle influence of the leaving group in anion-molecule nucleophilic substitution reactions. For this important class of reactions, as well as for many fundamental cation-molecule reactions, the information obtained with crossed-beam imaging is discussed. The first steps toward understanding micro-solvation of ion-molecule reaction dynamics are presented. We conclude with the presentation of several interesting directions for future research.

  7. Ion thruster performance model

    International Nuclear Information System (INIS)

    Brophy, J.R.

    1984-01-01

    A model of ion thruster performance is developed for high flux density cusped magnetic field thruster designs. This model is formulated in terms of the average energy required to produce an ion in the discharge chamber plasma and the fraction of these ions that are extracted to form the beam. The direct loss of high energy (primary) electrons from the plasma to the anode is shown to have a major effect on thruster performance. The model provides simple algebraic equations enabling one to calculate the beam ion energy cost, the average discharge chamber plasma ion energy cost, the primary electron density, the primary-to-Maxwellian electron density ratio and the Maxwellian electron temperature. Experiments indicate that the model correctly predicts the variation in plasma ion energy cost for changes in propellant gas (Ar, Kr, and Xe), grid transparency to neutral atoms, beam extraction area, discharge voltage, and discharge chamber wall temperature

  8. Electron-impact ionization of Pbq+ ions for q=1-10

    International Nuclear Information System (INIS)

    Loch, S.D.; Ludlow, J.A.; Pindzola, M.S.; Scheuermann, F.; Kramer, K.; Fabian, B.; Huber, K.; Salzborn, E.

    2005-01-01

    Theoretical calculations and experimental crossed-beam measurements are compared for electron-impact single ionization of Pb q+ ions for q=1-10. We compare with two main theoretical methods. First, we check against configuration-average distorted-wave calculations, which include both direct-ionization and indirect excitation-autoionization contributions. Second, for ion stages Pb + through to Pb 5+ , we calculate the dominant excitation-autoionization channels using level-resolved distorted-wave theory to evaluate the excitation cross sections. We find that for ion stages Pb + , Pb 2+ , and Pb 3+ , distorted-wave theory significantly overestimates the total-ionization cross section, due to an overestimation of the direct-ionization cross section from the 5d subshell. For ion stages Pb 4+ through to Pb 10+ there is good agreement between theory and experiment. We find evidence for significant metastable fraction in the ion beam of the experiment for ion stages Pb 2+ , Pb 3+ , Pb 4+ , Pb 5+ , and Pb 6+ . For ion stage Pb 3+ we find that the level-resolved distorted-wave calculation of the excitation autoionization results in a slight reduction of the configuration-average theoretical results, due to splitting of levels within the autoionizing configurations. We also investigate two semiempirical methods of calculating the direct-ionization cross sections: namely, the Lotz method and the binary encounter Bethe method. We find that both methods provide results which are significantly lower than the distorted-wave method for the 5d-subshell direct ionization of Pb + , Pb 2+ , and Pb 3+ . For the higher ion stages, both methods are lower than the distorted-wave direct-ionization cross-section results, trending towards the distorted-wave results as the ion stage increases

  9. Scalable Production of Si Nanoparticles Directly from Low Grade Sources for Lithium-Ion Battery Anode.

    Science.gov (United States)

    Zhu, Bin; Jin, Yan; Tan, Yingling; Zong, Linqi; Hu, Yue; Chen, Lei; Chen, Yanbin; Zhang, Qiao; Zhu, Jia

    2015-09-09

    Silicon, one of the most promising candidates as lithium-ion battery anode, has attracted much attention due to its high theoretical capacity, abundant existence, and mature infrastructure. Recently, Si nanostructures-based lithium-ion battery anode, with sophisticated structure designs and process development, has made significant progress. However, low cost and scalable processes to produce these Si nanostructures remained as a challenge, which limits the widespread applications. Herein, we demonstrate that Si nanoparticles with controlled size can be massively produced directly from low grade Si sources through a scalable high energy mechanical milling process. In addition, we systematically studied Si nanoparticles produced from two major low grade Si sources, metallurgical silicon (∼99 wt % Si, $1/kg) and ferrosilicon (∼83 wt % Si, $0.6/kg). It is found that nanoparticles produced from ferrosilicon sources contain FeSi2, which can serve as a buffer layer to alleviate the mechanical fractures of volume expansion, whereas nanoparticles from metallurgical Si sources have higher capacity and better kinetic properties because of higher purity and better electronic transport properties. Ferrosilicon nanoparticles and metallurgical Si nanoparticles demonstrate over 100 stable deep cycling after carbon coating with the reversible capacities of 1360 mAh g(-1) and 1205 mAh g(-1), respectively. Therefore, our approach provides a new strategy for cost-effective, energy-efficient, large scale synthesis of functional Si electrode materials.

  10. Fast-ion Dα measurements of the fast-ion distribution (invited)

    International Nuclear Information System (INIS)

    Heidbrink, W. W.

    2010-01-01

    The fast-ion Dα (FIDA) diagnostic is an application of charge-exchange recombination spectroscopy. Fast ions that neutralize in an injected neutral beam emit Balmer-α light with a large Doppler shift. The spectral shift is exploited to distinguish the FIDA emission from other bright sources of Dα light. Background subtraction is the main technical challenge. A spectroscopic diagnostic typically achieves temporal, energy, and transverse spatial resolution of ∼1 ms, ∼10 keV, and ∼2 cm, respectively. Installations that use narrow-band filters achieve high spatial and temporal resolution at the expense of spectral information. For high temporal resolution, the bandpass-filtered light goes directly to a photomultiplier, allowing detection of ∼50 kHz oscillations in FIDA signal. For two-dimensional spatial profiles, the bandpass-filtered light goes to a charge-coupled device camera; detailed images of fast-ion redistribution at instabilities are obtained. Qualitative and quantitative models relate the measured FIDA signals to the fast-ion distribution function. The first quantitative comparisons between theory and experiment found excellent agreement in beam-heated magnetohydrodynamics (MHD)-quiescent plasmas. FIDA diagnostics are now in operation at magnetic-fusion facilities worldwide. They are used to study fast-ion acceleration by ion cyclotron heating, to detect fast-ion transport by MHD modes and microturbulence, and to study fast-ion driven instabilities.

  11. Super TOF secondary ion mass spectroscopy using very highly charged primary ions up to Th70+

    International Nuclear Information System (INIS)

    Briere, M.A.; Schenkel, T.; Schneider, D.

    1995-01-01

    The LLNL Electron Beam Ion Trap (EBIT) has made low emittance beams of slow highly charged ions available for ion-solid interaction studies. Such interactions feature the dominance of electronic over collisional effects, and the shock waves generated by the ionized target atoms can desorb large numbers of large molecular species from the surface. This paper presents the first systematic study of the sputtering process due to the incidence of slow very highly charged ions; Th 70+ ions are extracted from EBIT at 7 keV * q and directed onto thin SiO 2 films on Si. Results suggest secondary ion yields of up to 25 per incident ion for Th 70+ (secondary ion yield is increased over that for singly or moderately charged ions). Correlations of the negative, positive, and negative cluster ion yields show promise for application of highly charged ion induced sputtering for enhanced sensitivity and quantitative (absolute) SIMS analysis of deep submicron scale surface layers and polymeric and biomolecular material analysis

  12. Pulsed, Inductively Generated, Streaming Plasma Ion Source for Heavy Ion Fusion Linacs

    International Nuclear Information System (INIS)

    Steven C. Glidden; Howard D Sanders; John B. Greenly; Daniel L. Dongwoo

    2006-01-01

    This report describes a compact, high current density, pulsed ion source, based on electrodeless, inductively driven gas breakdown, developed to meet the requirements on normalized emittance, current density, uniformity and pulse duration for an ion injector in a heavy-ion fusion driver. The plasma source produces >10 (micro)s pulse of Argon plasma with ion current densities >100 mA/cm2 at 30 cm from the source and with strongly axially directed ion energy of about 80 eV, and sub-eV transverse temperature. The source has good reproducibility and spatial uniformity. Control of the current density during the pulse has been demonstrated with a novel modulator coil method which allows attenuation of the ion current density without significantly affecting the beam quality. This project was carried out in two phases. Phase 1 used source configurations adapted from light ion sources to demonstrate the feasibility of the concept. In Phase 2 the performance of the source was enhanced and quantified in greater detail, a modulator for controlling the pulse shape was developed, and experiments were conducted with the ions accelerated to >40 kV

  13. The ''injection problem'' for quasiparallel shocks

    International Nuclear Information System (INIS)

    Zank, G. P.; Rice, W. K. M.; le Roux, J. A.; Cairns, I. H.; Webb, G. M.

    2001-01-01

    For a particle to be accelerated diffusively at a shock by the first-order Fermi acceleration mechanism, the particle must be sufficiently energetic that it can scatter across all the micro- and macrostructure of the shock, experiencing compression between the converging upstream and downstream states. This is the well-known ''injection problem.'' Here the interaction of ions with the ramp of a quasiparallel shock is investigated. Some ions incident on the shock experience specular reflection, caused either by the cross-shock electrostatic potential or by mirroring as the magnetic field is bent and compressed through the ramp. Scattering of reflected ions by self-generated and pre-existing turbulence in the region upstream of the shock then acts to trap backstreaming ions and return them to the ramp, where some experience further reflections. Such repeated reflections and scattering energize a subpopulation of ions up to energies sufficiently large that they can be diffusively shock accelerated. Two ion distributions are considered: pickup ions which are assumed to be described by a shell distribution, are thermal solar wind ions which may be described by a kappa distribution. Injection efficiencies are found analytically to be very high for pickup ions and much lower for thermal solar wind ions, suggesting that this injection mechanism, stochastic reflected ion or SRI acceleration, is a natural precursor for the acceleration of the anomalous cosmic ray component at a quasiparallel shock. While significantly less efficient, SRI acceleration is also viable for thermal solar wind ions described by a kappa distribution

  14. Do you know DIS? a novel passive individual dosimeterd. Direct Ion Storage dosimeter DIS-1 officially approved in Switzerland

    International Nuclear Information System (INIS)

    Fiechtner, A.; Wernli, C.

    2001-01-01

    For individual monitoring film and TLD are the most often used types of dosimeters. On a smaller scale phosphate glasses and detectors based on optically stimulated luminescence (OSL) are also in use. As a new addition to the list of available personnel dosimeters the direct ion storage (DIS) system became legally approved for the first time in Switzerland. At the Paul Scherrer Institute (PSI) the RADOS dosimetry system DIS-1 is in official use since beginning of 2001. (orig.) [de

  15. Development of C{sup 6+} laser ion source and RFQ linac for carbon ion radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sako, T., E-mail: takayuki1.sako@toshiba.co.jp; Yamaguchi, A.; Sato, K. [Toshiba Corporation, Yokohama 235-8522 (Japan); Goto, A.; Iwai, T.; Nayuki, T.; Nemoto, K.; Kayama, T. [Cancer Research Center, Yamagata University Faculty of Medicine, Yamagata 990-9585 (Japan); Takeuchi, T. [Accelerator Engineering Corporation, Chiba 263-0043 (Japan)

    2016-02-15

    A prototype C{sup 6+} injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4.

  16. Development of C⁶⁺ laser ion source and RFQ linac for carbon ion radiotherapy.

    Science.gov (United States)

    Sako, T; Yamaguchi, A; Sato, K; Goto, A; Iwai, T; Nayuki, T; Nemoto, K; Kayama, T; Takeuchi, T

    2016-02-01

    A prototype C(6+) injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4.

  17. Manipulation of inverted and direct opals by a focused ion beam scanning electron microscope (FIB SEM)

    International Nuclear Information System (INIS)

    Magni, S; Milani, M; Tatti, F; Savoia, C

    2008-01-01

    Focused ion beam (FIB) milling techniques are presented aiming at the manipulation of both tin dioxide (SnO 2 ) inverted opals and polystyrene (PS) direct opals. Different SnO 2 opals are considered in order to estimate the regularity of their bulk after the production. A SnO 2 mesoporous monolith is FIB micromachined to make it suitable for optical applications. PS direct opals are structured by FIB milling at different scales. Ordered arrays of PS opals are modified by selectively removing a single sphere. In performing this task, we discuss the effects on the FIB milling due to the gas-assisted enhanced etching and to the binding of the nearest neighbours. Techniques to achieve imaging of PS opals in absence of a conductive coating are also brought up. Furthermore, isolated PS spheres are drilled with or without enhanced etching in order to produce controlled defects on them. The FIB-assisted manipulations we show may find potential applications in the field of photonic crystals, (bio)sensors and lithography assisted by colloidal masks.

  18. What can we learn from the directed flow in heavy-ion collisions at BES RHIC energies?

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, Yu.B. [NRC ' ' Kurchatov Institute' ' , National Research Centre ' ' Kurchatov Institute' ' , Moscow (Russian Federation); Moscow Engineering Physics Institute, National Research Nuclear University ' ' MEPhI' ' , Moscow (Russian Federation); Soldatov, A.A. [Moscow Engineering Physics Institute, National Research Nuclear University ' ' MEPhI' ' , Moscow (Russian Federation)

    2016-01-15

    Analysis of directed flow (v{sub 1}) of protons, antiprotons and pions in heavy-ion collisions is performed in the range of collision energies √(s{sub NN}) = 2.7-39 GeV. Simulations have been done within a three-fluid model employing a purely hadronic equation of state (EoS) and two versions of the EoS with deconfinement transitions: a first-order phase transition and a smooth crossover transition. The crossover EoS is unambiguously preferable for the description of the most part of experimental data in this energy range. The directed flow indicates that the crossover deconfinement transition takes place in semicentral Au+Au collisions in a wide range of collision energies 4

  19. Ion cyclotron resonance heating

    International Nuclear Information System (INIS)

    Tajima, T.

    1982-01-01

    Ion cyclotron resonance heating of plasmas in tokamak and EBT configurations has been studied using 1-2/2 and 2-1/2 dimensional fully self-consistent electromagnetic particle codes. We have tested two major antenna configurations; we have also compared heating efficiencies for one and two ion species plasmas. We model a tokamak plasma with a uniform poloidal field and 1/R toroidal field on a particular q surface. Ion cyclotron waves are excited on the low field side by antennas parallel either to the poloidal direction or to the toroidal direction with different phase velocities. In 2D, minority ion heating (vsub(perpendicular)) and electron heating (vsub(parallel),vsub(perpendicular)) are observed. The exponential electron heating seems due to the decay instability. The minority heating is consistent with mode conversion of fast Alfven waves and heating by electrostatic ion cyclotron modes. Minority heating is stronger with a poloidal antenna. The strong electron heating is accompanied by toroidal current generation. In 1D, no thermal instability was observed and only strong minority heating resulted. For an EBT plasma we model it by a multiple mirror. We have tested heating efficiency with various minority concentrations, temperatures, mirror ratios, and phase velocities. In this geometry we have beach or inverse beach heating associated with the mode conversion layer perpendicular to the toroidal field. No appreciable electron heating is observed. Heating of ions is linear in time. For both tokamak and EBT slight majority heating above the collisional rate is observed due to the second harmonic heating. (author)

  20. Evaluation of metal ions in rice samples: extraction and direct determination by ICP OES

    International Nuclear Information System (INIS)

    Oliveira, Andrea; Cadore, Solange; Baccan, Nivaldo

    2012-01-01

    A method for extraction of metal ions present in rice samples using ammoniacal EDTA solution, pH = 10, as extractor agent is proposed under the following optimized conditions: 0.20 g of rice sample and 5.00 mL of ammoniacal EDTA (ethylenediaminetetraacetic acid) solution, with 5 min of ultrasound exposure time. Using robust ICP OES (inductively coupled plasma atomic emission spectrometry) conditions, direct analysis of the extraction solution was allowed, and the recovery values obtained were above 90% for most of the studied elements (P, K, Mg, Ca, Zn, Mn, Cu and Mo) with RSD -1 (Mn) - 48.68 mg kg -1 (K), showing adequate detectability for the determination of the analytes. The analysis of different samples indicated that Brazilian 'integral' rice contains higher contents of the constituents studied, followed by 'parboiled' rice, and the 'agulhinha' rice a long and thin grain type. (author)

  1. Ion irradiation studies of oxide ceramics

    International Nuclear Information System (INIS)

    Zinkle, S.J.

    1988-01-01

    This paper presents the initial results of an investigation of the depth-dependent microstructures of three oxide ceramics following ion implantation to moderate doses. The implantations were performed using ion species that occur as cations in the target material; for example, Mg + ions were used for MgO and MgAl 2 O 4 (spinel) irradiations. This minimized chemical effects associated with the implantation and allowed a more direct evaluation to be made of the effects of implanted ions on the microstructure. 11 refs., 14 figs

  2. Effect of the Ion Mass and Energy on the Response of 70-nm SOI Transistors to the Ion Deposited Charge by Direct Ionization

    International Nuclear Information System (INIS)

    Raine, M.; Gaillardin, M.; Sauvestre, J.E.; Flament, O.; Bournel, A.; Aubry-Fortuna, V.

    2010-01-01

    The response of SOI transistors under heavy ion irradiation is analyzed using Geant4 and Synopsys Sentaurus device simulations. The ion mass and energy have a significant impact on the radial ionization profile of the ion deposited charge. For example, for an identical LET, the higher the ion energy per nucleon, the wider the radial ionization track. For a 70-nm SOI technology, the track radius of high energy ions (≥ 10 MeV/a) is larger than the transistor sensitive volume; part of the ion charge recombines in the highly doped source or drain regions and does not participate to the transistor electric response. At lower energy (≤ 10 MeV/a), as often used for ground testing, the track radius is smaller than the transistor sensitive volume, and the entire charge is used for the transistor response. The collected charge is then higher, corresponding to a worst-case response of the transistor. Implications for the hardness assurance of highly-scaled generations are discussed. (authors)

  3. Electrical enhancement of direct methanol fuel cells by metal-plasma ion implantation Pt-Ru/C multilayer catalysts.

    Science.gov (United States)

    Weng, Ko-Wei; Chen, Yung-Lin; Chen, Ya-Chi; Lin, Tai-Nan

    2009-02-01

    Direct methanol fuel cells (DMFC) have been widely studied owing to their simple cell configuration, high volume energy density, short start-up time, high operational reliability and other favorable characteristics. However, major limitations include high production cost, poisoning of the catalyst and methanol crossover. This study adopts a simple technique for preparing Pt-Ru/C multilayer catalysts, including magnetron sputtering (MS) and metal-plasma ion implantation (MPII). The Pt catalysts were sputtered onto the gas diffusion layer (GDL), followed by the implantation of Ru catalysts using MPII (at an accelerating voltage of 20 kV and an implantation dose of 1 x 10(16) ions/cm2). Pt-Ru is repeatedly processed to prepare Pt-Ru/C multilayer catalysts. The catalyst film structure and microstructure were analyzed by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and scanning electronic microscopy (SEM), respectively. The cell performance was tested using a potential stat/galvano-stat. The results reveal that the membrane electrode assembly (MEA) of four multilayer structures enhances the cell performance of DMFC. The measured power density is 2.2 mW/cm2 at a methanol concentration of 2 M, with an OCV of 0.493 V.

  4. Gas-phase ion/ion reactions of peptides and proteins: acid/base, redox, and covalent chemistries.

    Science.gov (United States)

    Prentice, Boone M; McLuckey, Scott A

    2013-02-01

    Gas-phase ion/ion reactions are emerging as useful and flexible means for the manipulation and characterization of peptide and protein biopolymers. Acid/base-like chemical reactions (i.e., proton transfer reactions) and reduction/oxidation (redox) reactions (i.e., electron transfer reactions) represent relatively mature classes of gas-phase chemical reactions. Even so, especially in regards to redox chemistry, the widespread utility of these two types of chemistries is undergoing rapid growth and development. Additionally, a relatively new class of gas-phase ion/ion transformations is emerging which involves the selective formation of functional-group-specific covalent bonds. This feature details our current work and perspective on the developments and current capabilities of these three areas of ion/ion chemistry with an eye towards possible future directions of the field.

  5. Response of thermal ions to electromagnetic ion cyclotron waves

    Science.gov (United States)

    Anderson, B. J.; Fuselier, S. A.

    1994-01-01

    Electromagnetic ion cyclotron waves generated by 10 - 50 keV protons in the Earth's equatorial magnetosphere will interact with the ambient low-energy ions also found in this region. We examine H(+) and He(+) distribution functions from approx. equals 1 to 160 eV using the Hot Plasma Composition Experiment instrument on AMPTE/CCE to investigate the thermal ion response to the waves. A total of 48 intervals were chosen on the basis of electromagnetic ion cyclotron (EMIC) wave activity: 24 with prevalent EMIC waves and 24 with no EMIC waves observed on the orbit. There is a close correlation between EMIC waves and perpendicular heated ion distributions. For protons the perpendicular temperature increase is modest, about 5 eV, and is always observed at 90 deg pitch angles. This is consistent with a nonresonant interaction near the equator. By contrast, He(+) temperatures during EMIC wave events averaged 35 eV and sometimes exceeded 100 eV, indicating stronger interaction with the waves. Furthermore, heated He(+) ions have X-type distributions with maximum fluxes occurring at pitch angles intermediate between field-aligned and perpendicular directions. The X-type He(+) distributions are consistent with a gyroresonant interaction off the equator. The concentration of He(+) relative to H(+) is found to correlate with EMIC wave activity, but it is suggested that the preferential heating of He(+) accounts for the apparent increase in relative He(+) concentration by increasing the proportion of He(+) detected by the ion instrument.

  6. On the meniscus formation and the negative hydrogen ion extraction from ITER neutral beam injection relevant ion source

    Science.gov (United States)

    Mochalskyy, S.; Wünderlich, D.; Ruf, B.; Fantz, U.; Franzen, P.; Minea, T.

    2014-10-01

    The development of a large area (Asource,ITER = 0.9 × 2 m2) hydrogen negative ion (NI) source constitutes a crucial step in construction of the neutral beam injectors of the international fusion reactor ITER. To understand the plasma behaviour in the boundary layer close to the extraction system the 3D PIC MCC code ONIX is exploited. Direct cross checked analysis of the simulation and experimental results from the ITER-relevant BATMAN source testbed with a smaller area (Asource,BATMAN ≈ 0.32 × 0.59 m2) has been conducted for a low perveance beam, but for a full set of plasma parameters available. ONIX has been partially benchmarked by comparison to the results obtained using the commercial particle tracing code for positive ion extraction KOBRA3D. Very good agreement has been found in terms of meniscus position and its shape for simulations of different plasma densities. The influence of the initial plasma composition on the final meniscus structure was then investigated for NIs. As expected from the Child-Langmuir law, the results show that not only does the extraction potential play a crucial role on the meniscus formation, but also the initial plasma density and its electronegativity. For the given parameters, the calculated meniscus locates a few mm downstream of the plasma grid aperture provoking a direct NI extraction. Most of the surface produced NIs do not reach the plasma bulk, but move directly towards the extraction grid guided by the extraction field. Even for artificially increased electronegativity of the bulk plasma the extracted NI current from this region is low. This observation indicates a high relevance of the direct NI extraction. These calculations show that the extracted NI current from the bulk region is low even if a complete ion-ion plasma is assumed, meaning that direct extraction from surface produced ions should be present in order to obtain sufficiently high extracted NI current density. The calculated extracted currents, both ions

  7. Many-electron phenomena in the ionization of ions

    International Nuclear Information System (INIS)

    Mueller, A.

    2004-01-01

    Full text: Single and multiple ionization in ion-atom collisions involve a multitude of complex interactions between the electrons and nuclei of projectile and target. Some of the complexity is avoided in studies of fast collisions when the impulse approximation can be applied and the electrons can be described as independent quasi-free particles with a known momentum distribution. For the detailed investigation of ionization mechanisms that can occur in fast ion-atom collisions, it is illuminating to consider collisions of ions (or atoms) and really free electrons with a narrow energy spread. High energy resolution in electron-ion collision studies provides access to individual, possibly even state-selective, reaction pathways. Even in the simple electron-ion collision system (simple compared with the initial ion-atom problem) single and multiple ionization still involve a multitude of complex mechanisms. Besides the direct removal of one or several electrons from the target by electron impact, resonant and non-resonant formation of intermediate multiply excited states which subsequently decay by electron emission is important in single and multiple ionization of ions and atoms. Direct ionization proceeds via one-step or multi-step knock-off mechanisms which can partly be disentangled by studying effects of different projectile species. The role of multiply excited states in the ionization can be experimentally studied in great detail by a further reduction of the initial ion-atom problem. Multiply excited states of atoms and ions can be selectively populated by photon-ion interactions making use of the potential for extreme energy resolution made available at modern synchrotron radiation sources. In the review talk, examples of studies on single and multiple ionization in electron-ion collisions will be discussed in some detail. Electron-ion collision experiments will also be compared with photon-ion interaction studies. Many-electron phenomena have been observed

  8. Direct Comparison of Biologically Optimized Spread-out Bragg Peaks for Protons and Carbon Ions

    International Nuclear Information System (INIS)

    Wilkens, Jan J.; Oelfke, Uwe

    2008-01-01

    Purpose: In radiotherapy with hadrons, it is anticipated that carbon ions are superior to protons, mainly because of their biological properties: the relative biological effectiveness (RBE) for carbon ions is supposedly higher in the target than in the surrounding normal tissue, leading to a therapeutic advantage over protons. The purpose of this report is to investigate this effect by using biological model calculations. Methods and Materials: We compared spread-out Bragg peaks for protons and carbon ions by using physical and biological optimization. The RBE for protons and carbon ions was calculated according to published biological models. These models predict increased RBE values in regions of high linear energy transfer (LET) and an inverse dependency of the RBE on dose. Results: For pure physical optimization, protons yield a better dose distribution along the central axis. In biologically optimized plans, RBE variations for protons were relatively small. For carbon ions, high RBE values were found in the high-LET target region, as well as in the low-dose region outside the target. This means that the LET dependency and dose dependency of the RBE can cancel each other. We show this for radioresistant tissues treated with two opposing beams, for which the predicted carbon RBE within the target volume was lower than outside. Conclusions: For tissue parameters used in this study, the model used does not predict a biologic advantage of carbon ions. More reliable model parameters and clinical trials are necessary to explore the true potential of radiotherapy with carbon ions

  9. Ion implantation apparatus

    International Nuclear Information System (INIS)

    Forneris, J.L.; Hicks, W.W.; Keller, J.H.; McKenna, C.M.; Siermarco, J.A.; Mueller, W.F.

    1981-01-01

    The invention relates to ion bombardment or implantation apparatus. It comprises an apparatus for bombarding a target with a beam of ions, including an arrangement for measuring the ion beam current and controlling the surface potential of the target. This comprises a Faraday cage formed, at least in part, by the target and by walls adjacent to, and electrically insulated from, the target and surrounding the beam. There is at least one electron source for supplying electrons to the interior of the Faraday cage and means within the cage for blocking direct rectilinear radiation from the source to the target. The target current is measured and combined with the wall currents to provide a measurement of the ion beam current. The quantity of electrons supplied to the interior of the cage can be varied to control the target current and thereby the target surface potential. (U.K.)

  10. Cleavage reactions of the complex ions derived from self-complementary deoxydinucleotides and alkali-metal ions using positive ion electrospray ionization with tandem mass spectrometry.

    Science.gov (United States)

    Xiang, Yun; Abliz, Zeper; Takayama, Mitsuo

    2004-05-01

    The dissociation reactions of the adduct ions derived from the four self-complementary deoxydinucleotides, d(ApT), d(TpA), d(CpG), d(GpC), and alkali-metal ions were studied in detail by positive ion electrospray ionization multiple-stage mass spectrometry (ESI-MS(n)). For the [M + H](+) ions of the four deoxydinucleotides, elimination of 5'-terminus base or loss of both of 5'-terminus base and a deoxyribose were the major dissociation pathway. The ESI-MS(n) spectra showed that Li(+), Na(+), and Cs(+) bind to deoxydinucleotides mainly by substituting the H(+) of phosphate group, and these alkali-metal ions preferred to bind to pyrimidine bases rather than purine bases. For a given deoxydinucleotide, the dissociation pathway of [M + K](+) ions differed clearly from that of [M + Li](+), [M + Na](+), and [M + Cs](+) ions. Some interesting and characteristic cleavage reactions were observed in the product-ion spectra of [M + K](+) ions, including direct elimination of deoxyribose and HPO(3) from molecular ions. The fragmentation behavior of the [M + K](+) and [M + W](+) (W = Li, Na, Cs) adduct ions depend upon the sequence of bases, the interaction between alkali-metal ions and nucleobases, and the steric hindrance caused by bases.

  11. Clinic Attendance for Antiretroviral Pills Pick-Up among HIV-Positive People in Nepal: Roles of Perceived Family Support and Associated Factors.

    Science.gov (United States)

    Ayer, Rakesh; Kikuchi, Kimiyo; Ghimire, Mamata; Shibanuma, Akira; Pant, Madhab Raj; Poudel, Krishna C; Jimba, Masamine

    2016-01-01

    HIV-positive people's clinic attendance for medication pick-up is critical for successful HIV treatment. However, limited evidence exists on it especially in low-income settings such as Nepal. Moreover, the role of family support in clinic attendance remains under-explored. Therefore, this study was conducted to examine the association between perceived family support and regular clinic attendance and to assess factors associated with regular clinic attendance for antiretroviral pills pick-up among HIV-positive individuals in Nepal. A cross-sectional study was conducted among 423 HIV-positive people in three districts of Nepal. Clinic attendance was assessed retrospectively for the period of 12 months. To assess the factors associated, an interview survey was conducted using a semi-structured questionnaire from July to August, 2015. Multiple logistic regression models were used to assess the factors associated with regular clinic attendance. Of 423 HIV-positive people, only 32.6% attended the clinics regularly. They were more likely to attend them regularly when they received high family support (AOR = 3.98, 95% CI = 2.29, 6.92), participated in support programs (AOR = 1.68, 95% CI = 1.00, 2.82), and had knowledge on the benefits of antiretroviral therapy (AOR = 2.62, 95% CI = 1.15, 5.99). In contrast, they were less likely to attend them regularly when they commuted more than 60 minutes to the clinics (AOR = 0.53, 95% CI = 0.30, 0.93), when they self-rated their health status as being very good (AOR = 0.13, 95% CI = 0.04, 0.44), good (AOR = 0.14, 95% CI = 0.04, 0.46), and fair (AOR = 0.21, 95% CI = 0.06, 0.70). HIV-positive individuals are more likely to attend the clinics regularly when they receive high family support, know the benefits of antiretroviral therapy, and participate in support programs. To improve clinic attendance, family support should be incorporated with HIV care programs in resource limited settings. Service providers should also consider

  12. Clinic Attendance for Antiretroviral Pills Pick-Up among HIV-Positive People in Nepal: Roles of Perceived Family Support and Associated Factors

    Science.gov (United States)

    Kikuchi, Kimiyo; Ghimire, Mamata; Shibanuma, Akira; Pant, Madhab Raj; Poudel, Krishna C.; Jimba, Masamine

    2016-01-01

    Introduction HIV-positive people’s clinic attendance for medication pick-up is critical for successful HIV treatment. However, limited evidence exists on it especially in low-income settings such as Nepal. Moreover, the role of family support in clinic attendance remains under-explored. Therefore, this study was conducted to examine the association between perceived family support and regular clinic attendance and to assess factors associated with regular clinic attendance for antiretroviral pills pick-up among HIV-positive individuals in Nepal. Methods A cross-sectional study was conducted among 423 HIV-positive people in three districts of Nepal. Clinic attendance was assessed retrospectively for the period of 12 months. To assess the factors associated, an interview survey was conducted using a semi-structured questionnaire from July to August, 2015. Multiple logistic regression models were used to assess the factors associated with regular clinic attendance. Results Of 423 HIV-positive people, only 32.6% attended the clinics regularly. They were more likely to attend them regularly when they received high family support (AOR = 3.98, 95% CI = 2.29, 6.92), participated in support programs (AOR = 1.68, 95% CI = 1.00, 2.82), and had knowledge on the benefits of antiretroviral therapy (AOR = 2.62, 95% CI = 1.15, 5.99). In contrast, they were less likely to attend them regularly when they commuted more than 60 minutes to the clinics (AOR = 0.53, 95% CI = 0.30, 0.93), when they self-rated their health status as being very good (AOR = 0.13, 95% CI = 0.04, 0.44), good (AOR = 0.14, 95% CI = 0.04, 0.46), and fair (AOR = 0.21, 95% CI = 0.06, 0.70). Conclusion HIV-positive individuals are more likely to attend the clinics regularly when they receive high family support, know the benefits of antiretroviral therapy, and participate in support programs. To improve clinic attendance, family support should be incorporated with HIV care programs in resource limited settings

  13. The ion circus

    Energy Technology Data Exchange (ETDEWEB)

    Minaya Ramirez, Enrique [GSI Helmholtzzentrum, Darmstadt (Germany); Lunney, David [CSNSM- IN2P3/CNRS, Universite de Paris-Sud, Orsay (France)

    2010-07-01

    The ability to prepare radioactive beams for experiments in nuclear structure has seen important developments in recent years. The use of ion traps and buffer-gas cooling now enables the accumulation and purification of even short-lived nuclides. This is a key point for future installations since higher intensity also brings increased isobaric contamination which can be disastrous for background. Until now, the development of beam cooler/bunchers has relied on linear (radiofrequency quadrupole) Paul traps. In this contribution we describe the progress in developing a novel circular Paul trap. The ion circus, so named for its ability to trap ions at different positions along the ring circumference and to eject them in either perpendicular or tangential direction, has also been designed to cool and mass separate the ions over a longer flight path. The resolving power is increased as the ions orbit in the ring and are cooled with buffer gas at a much lower pressure. The first prototype is now under test in Orsay. We report results of the first tests and the future program.

  14. Molecular ion photofragment spectroscopy

    International Nuclear Information System (INIS)

    Bustamente, S.W.

    1983-11-01

    A new molecular ion photofragment spectrometer is described which features a supersonic molecular beam ion source and a radio frequency octapole ion trap interaction region. This unique combination allows several techniques to be applied to the problem of detecting a photon absorption event of a molecular ion. In particular, it may be possible to obtain low resolution survey spectra of exotic molecular ions by using a direct vibrational predissociation process, or by using other more indirect detection methods. The use of the spectrometer is demonstrated by measuring the lifetime of the O 2 + ( 4 π/sub u/) metastable state which is found to consist of two main components: the 4 π/sub 5/2/ and 4 π/sub -1/2/ spin components having a long lifetime (approx. 129 ms) and the 4 π/sub 3/2/ and 4 π/sub 1/2/ spin components having a short lifetime (approx. 6 ms)

  15. Graphene defects induced by ion beam

    Science.gov (United States)

    Gawlik, Grzegorz; Ciepielewski, Paweł; Baranowski, Jacek; Jagielski, Jacek

    2017-10-01

    The CVD graphene deposited on the glass substrate was bombarded by molecular carbon ions C3+ C6+ hydrocarbon ions C3H4+ and atomic ions He+, C+, N+, Ar+, Kr+ Yb+. Size and density of ion induced defects were estimated from evolution of relative intensities of Raman lines D (∼1350 1/cm), G (∼1600 1/cm), and D‧ (∼1620 1/cm) with ion fluence. The efficiency of defect generation by atomic ions depend on ion mass and energy similarly as vacancy generation directly by ion predicted by SRIM simulations. However, efficiency of defect generation in graphene by molecular carbon ions is essentially higher than summarized efficiency of similar group of separate atomic carbon ions of the same energy that each carbon ion in a cluster. The evolution of the D/D‧ ratio of Raman lines intensities with ion fluence was observed. This effect may indicate evolution of defect nature from sp3-like at low fluence to a vacancy-like at high fluence. Observed ion graphene interactions suggest that the molecular ion interacts with graphene as single integrated object and should not be considered as a group of atomic ions with partial energy.

  16. The smoke ion source: A device for the generation of cluster ions via inert gas condensation

    International Nuclear Information System (INIS)

    McHugh, K.M.; Sarkas, H.W.; Eaton, J.G.; Bowen, K.H.; Westgate, C.R.

    1989-01-01

    We report the development of an ion source for generating intense, continuous beams of both positive and negative cluster ions. This device is the result of the marriage of the inert gas condensation method with techniques for injecting electrons directly into expanding jets. In the preliminary studies described here, we have observed cluster ion size distributions ranging from n=1-400 for Pb n + and Pb n - and from n=12-5700 for Li n - . (orig.)

  17. Voyager observations of the interaction of the heliosphere with the interstellar medium

    Directory of Open Access Journals (Sweden)

    John D. Richardson

    2013-05-01

    Full Text Available This paper provides a brief review and update on the Voyager observations of the interaction of the heliosphere with the interstellar medium. Voyager has found many surprises: (1 a new energetic particle component which is accelerated at the termination shock (TS and leaks into the outer heliosphere forming a foreshock region; (2 a termination shock which is modulated by energetic particles and which transfers most of the solar wind flow energy to the pickup ions (not the thermal ions; (3 the heliosphere is asymmetric; (4 the TS does not accelerate anomalous cosmic rays at the Voyager locations; and (5 the plasma flow in the Voyagers 1 (V1 and 2 (V2 directions are very different. At V1 the flow was small after the TS and has recently slowed to near zero, whereas at V2 the speed has remained constant while the flow direction has turned tailward. V1 may have entered an extended boundary region in front of the heliopause (HP in 2010 in which the plasma flow speeds are near zero.

  18. Voyager observations of the interaction of the heliosphere with the interstellar medium.

    Science.gov (United States)

    Richardson, John D

    2013-05-01

    This paper provides a brief review and update on the Voyager observations of the interaction of the heliosphere with the interstellar medium. Voyager has found many surprises: (1) a new energetic particle component which is accelerated at the termination shock (TS) and leaks into the outer heliosphere forming a foreshock region; (2) a termination shock which is modulated by energetic particles and which transfers most of the solar wind flow energy to the pickup ions (not the thermal ions); (3) the heliosphere is asymmetric; (4) the TS does not accelerate anomalous cosmic rays at the Voyager locations; and (5) the plasma flow in the Voyagers 1 (V1) and 2 (V2) directions are very different. At V1 the flow was small after the TS and has recently slowed to near zero, whereas at V2 the speed has remained constant while the flow direction has turned tailward. V1 may have entered an extended boundary region in front of the heliopause (HP) in 2010 in which the plasma flow speeds are near zero.

  19. Contribution to the study of heavy-ion induced quasi-elastic processes in the 2s-1d shell

    International Nuclear Information System (INIS)

    Greiner, A.

    1982-06-01

    In the first part of this thesis, we present a study of the charge exchange reaction 28 Si( 18 O, 18 F) 28 Al at 56 MeV. This reaction can be easily understood in terms of a one-step direct charge exchange mechanism. With a very simple shell model, it can be interpreted that a neutron of the 18 O in the Jsup(π)=0 + , T=1 state interacts with a proton in the dsub(5/2) shell of 28 Si and they exchange their spin and charge forming Jsup(π)=1 + , T=0 18 F, and Jsup(π)=3 + or 2 + , T=1 28 Al. In the present analysis of data, we have first performed the direct charge exchange DWBA calculations. These results are compared with the exact-finite-range (EFR) second order DWBA calculations which take into account the successive one-nucleon stripping and pickup, and pickup and stripping process. In the second part, we wish to report results and analysis concerning the 24 Mg+ 12 C system. The 180 0 c.m. angle scattering excitation functions were measured between 12- and 27-MeV c.m. corresponding to a range in the compound 36 Ar excitation energy of 28.3 to 43.3 MeV. Several angular distributions for the elastic and inelastic scattering have been measured on the top of the bumps of the elastic scattering excitation function. These elastic scattering angular distributions cannot be fitted by a single squared Legendre polynomial of order L. A complete phase shift analysis is presented. We discuss also the shapes of the first 24 Mg 2 + inelastic scattering angular distributions with respect to the shape of the elastic scattering differential cross section [fr

  20. Ion funnel device

    Energy Technology Data Exchange (ETDEWEB)

    Ibrahim, Yehia M.; Chen, Tsung-Chi; Harrer, Marques B.; Tang, Keqi; Smith, Richard D.

    2017-11-21

    An ion funnel device is disclosed. A first pair of electrodes is positioned in a first direction. A second pair of electrodes is positioned in a second direction. The device includes an RF voltage source and a DC voltage source. A RF voltage with a superimposed DC voltage gradient is applied to the first pair of electrodes, and a DC voltage gradient is applied to the second pair of electrodes.

  1. Nanopore Device for Reversible Ion and Molecule Sensing or Migration

    Science.gov (United States)

    Pourmand, Nader (Inventor); Vilozny, Boaz (Inventor); Actis, Paolo (Inventor); Seger, R. Adam (Inventor); Singaram, Bakthan (Inventor)

    2015-01-01

    Disclosed are methods and devices for detection of ion migration and binding, utilizing a nanopipette adapted for use in an electrochemical sensing circuit. The nanopipette may be functionalized on its interior bore with metal chelators for binding and sensing metal ions or other specific binding molecules such as boronic acid for binding and sensing glucose. Such a functionalized nanopipette is comprised in an electrical sensor that detects when the nanopipette selectively and reversibly binds ions or small molecules. Also disclosed is a nanoreactor, comprising a nanopipette, for controlling precipitation in aqueous solutions by voltage-directed ion migration, wherein ions may be directed out of the interior bore by a repulsing charge in the bore.

  2. 2010 ion run: completed!

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    After a very fast switchover from protons to lead ions, the LHC has achieved performances that allowed the machine to exceed both peak and integrated luminosity by a factor of three. Thanks to this, experiments have been able to produce high-profile results on ion physics almost immediately, confirming that the LHC was able to keep its promises for ions as well as for protons.   First direct observation of jet quenching. A seminar on 2 December was the opportunity for the ALICE, ATLAS and CMS collaborations to present their first results on ion physics in front of a packed auditorium. These results are important and are already having a major impact on the understanding of the physics processes that involve the basic constituents of matter at high energies. In the ion-ion collisions, the temperature is so high that partons (quarks and gluons), which are usually constrained inside the nucleons, are deconfined to form a highly dense and hot soup known as quark-gluon plasma (QGP). The existence of ...

  3. Negative hydrogen ion production mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Bacal, M. [UPMC, LPP, Ecole Polytechnique, UMR CNRS 7648, Palaiseau (France); Wada, M. [School of Science and Engineering, Doshisha University, Kyoto 610-0321 (Japan)

    2015-06-15

    Negative hydrogen/deuterium ions can be formed by processes occurring in the plasma volume and on surfaces facing the plasma. The principal mechanisms leading to the formation of these negative ions are dissociative electron attachment to ro-vibrationally excited hydrogen/deuterium molecules when the reaction takes place in the plasma volume, and the direct electron transfer from the low work function metal surface to the hydrogen/deuterium atoms when formation occurs on the surface. The existing theoretical models and reported experimental results on these two mechanisms are summarized. Performance of the negative hydrogen/deuterium ion sources that emerged from studies of these mechanisms is reviewed. Contemporary negative ion sources do not have negative ion production electrodes of original surface type sources but are operated with caesium with their structures nearly identical to volume production type sources. Reasons for enhanced negative ion current due to caesium addition to these sources are discussed.

  4. An Induction Linac Driver For A 0.44 MJ Heavy-Ion Direct Drive Target

    International Nuclear Information System (INIS)

    Seidl, P.A.; Lee, E.P.; Bangerter, R.O.; Faltens, A.

    2010-01-01

    The conceptual design of a heavy ion fusion driver system is described, including all major components. Particular issues emerging from this exercise are identified and discussed. The most important conclusion of our study is that due to stringent requirements on ion pulse phase space, we are unable to find a credible accelerator design that meets the requirements of the example target. Either the target design must be modified to accept larger ion ranges and larger focal spot sizes, or we must consider other target options.

  5. Asymmetric ion transport through ion-channel-mimetic solid-state nanopores.

    Science.gov (United States)

    Guo, Wei; Tian, Ye; Jiang, Lei

    2013-12-17

    Both scientists and engineers are interested in the design and fabrication of synthetic nanofluidic architectures that mimic the gating functions of biological ion channels. The effort to build such structures requires interdisciplinary efforts at the intersection of chemistry, materials science, and nanotechnology. Biological ion channels and synthetic nanofluidic devices have some structural and chemical similarities, and therefore, they share some common features in regulating the traverse ionic flow. In the past decade, researchers have identified two asymmetric ion transport phenomena in synthetic nanofluidic structures, the rectified ionic current and the net diffusion current. The rectified ionic current is a diode-like current-voltage response that occurs when switching the voltage bias. This phenomenon indicates a preferential direction of transport in the nanofluidic system. The net diffusion current occurs as a direct product of charge selectivity and is generated from the asymmetric diffusion through charged nanofluidic channels. These new ion transport phenomena and the elaborate structures that occur in biology have inspired us to build functional nanofluidic devices for both fundamental research and practical applications. In this Account, we review our recent progress in the design and fabrication of biomimetic solid-state nanofluidic devices with asymmetric ion transport behavior. We demonstrate the origin of the rectified ionic current and the net diffusion current. We also identify several influential factors and discuss how to build these asymmetric features into nanofluidic systems by controlling (1) nanopore geometry, (2) surface charge distribution, (3) chemical composition, (4) channel wall wettability, (5) environmental pH, (6) electrolyte concentration gradient, and (7) ion mobility. In the case of the first four features, we build these asymmetric features directly into the nanofluidic structures. With the final three, we construct

  6. H- formation process in a multicusp ion source

    International Nuclear Information System (INIS)

    Leung, K.N.; Kunkel, W.B.

    1987-07-01

    In recent years, H - ions have been found important applications in high energy accelerators and in neutral beam heating of fusion plasmas. There are different techniques for producing the H - or D - ions. The most attractive scheme is the direct extraction of H - ions from a hydrogen discharge. This technique requires no cesium and it utilizes the existing large area positive ion source technology. This paper investigates this techniques. 14 refs

  7. Apparatus and method for extracting power from energetic ions produced in nuclear fusion

    Science.gov (United States)

    Fisch, Nathaniel J.; Rax, Jean M.

    1994-01-01

    An apparatus and method of extracting power from energetic ions produced by nuclear fusion in a toroidal plasma to enhance respectively the toroidal plasma current and fusion reactivity. By injecting waves of predetermined frequency and phase traveling substantially in a selected poloidal direction within the plasma, the energetic ions become diffused in energy and space such that the energetic ions lose energy and amplify the waves. The amplified waves are further adapted to travel substantially in a selected toroidal direction to increase preferentially the energy of electrons traveling in one toroidal direction which, in turn, enhances or generates a toroidal plasma current. In an further adaptation, the amplified waves can be made to preferentially increase the energy of fuel ions within the plasma to enhance the fusion reactivity of the fuel ions. The described direct, or in situ, conversion of the energetic ion energy provides an efficient and economical means of delivering power to a fusion reactor.

  8. Gamma irradiation testing of prototype ITER in-vessel magnetic pick-up coils

    International Nuclear Information System (INIS)

    Vermeeren, Ludo; Leysen, Willem

    2013-01-01

    Highlights: ► We tested five prototype ITER in-vessel coils up to a gamma dose of 72 MGy. ► Before and after irradiation thermal tests were also performed from 30 °C till 130 °C. ► The continuity resistances and the insulation resistances were continuously monitored. ► The observed behavior of all coils was satisfactory in all conditions. ► For the further design the mechanical robustness should be taken into account. -- Abstract: To fulfill the requirements for ITER in-vessel magnetic diagnostics, several coil prototypes have been developed, aiming at minimizing the disturbing effects of temperature gradients and radiation induced phenomena. As a first step in the radiation resistance testing of these prototypes, an in-situ high dose rate gamma radiation test on a selection of prototypes was performed. The aim of this test was to get a first experimental feedback regarding the behavior of the pick-up coil prototypes under radiation. Five prototypes (a coil wound with glass-insulated copper wire, two LTCC coils and two HTCC coils) were irradiated at a dose rate of 46 kGy/h up to a total dose of 72 MGy and at a temperature of 50 °C. During the irradiation, the continuity resistances and the insulation resistances were continuously measured. Before and after irradiation reference data were recorded as a function of temperature (from 30 °C to 130 °C). This paper includes the results of the temperature and irradiation tests and a discussion of the behavior of the prototype coils in terms of electrical and mechanical properties

  9. Trapped ion depletion by anomalous diffusion due to the dissipative trapped ion instability

    International Nuclear Information System (INIS)

    Wimmel, H.K.

    1975-07-01

    At high temperatures the KADOMTSEV-POGUTSE diffusion in tokamaks can become so large as to cause depletion of trapped ions if these are replaced with free ions by means of collisions rather than being directly recycled or injected. Modified KADOMTSEV-POGUTSE diffusion formulas are employed in order to estimate this effect in the cases of classical and anomalous collisions. The maximum trapped-ion depletion is estimated from the PENROSE stability condition. For anomalous collisions a BOHM-type diffusion is derived. Numerical examples are given for JET-like parameters (JET = Joint European Torus). Depletion is found to reduce diffusion by factors of up to 10 and more. (orig.) [de

  10. Control of Strobilurin Fungicides in Wheat Using Direct Analysis in Real Time Accurate Time-of-Flight and Desorption Electrospray Ionization Linear Ion Trap Mass Spectrometry

    NARCIS (Netherlands)

    Schurek, J.; Vaclavik, L.; Hooijerink, H.; Lacina, O.; Poustka, J.; Sharman, M.; Caldow, M.; Nielen, M.W.F.; Hajslova, J.

    2008-01-01

    Ambient mass spectrometry has been used for the analysis of strobilurin residues in wheat. The use of this novel, challenging technique, employing a direct analysis in a real time (DART) ion-source coupled with a time-of-flight mass spectrometer (TOF MS) and a desorption electrospray ionization

  11. Design of a negative ion neutral beam system for TNS

    International Nuclear Information System (INIS)

    Easoz, J.R.; Sink, D.A.

    1979-01-01

    A design is presented that suggests that a negative ion neutral beam based on direct extraction is applicable to TNS, assuming technological advancements in several areas. Improvements in negative ion sources, direct energy conversion of charged beams, and high speed cryogenic pumping are needed. The increase in efficiency over a positive ion system and the encouraging results of the first attempt at a total design justify increased effort in the development of the above mentioned areas

  12. Alkynylcarbenium ions and related unsaturated cations

    Energy Technology Data Exchange (ETDEWEB)

    Lukyanov, Sergey M; Koblik, Alla V; Muradyan, Lyudmila A [Institute of Physical and Organic Chemistry, Rostov State University, Rostov-on-Don (Russian Federation)

    1998-10-31

    Published data on carbenium ions containing carbon-carbon triple bonds both directly conjugated with the carbenium centre and separated from it are surveyed and described systematically. Ammonium, diazonium, iminium, phosphonium and iodonium cations containing alkynyl groups, which can be regarded as heteroanalogues of alkynylcarbenium ions, are also considered. The bibliography includes 283 references.

  13. Alkynylcarbenium ions and related unsaturated cations

    International Nuclear Information System (INIS)

    Lukyanov, Sergey M; Koblik, Alla V; Muradyan, Lyudmila A

    1998-01-01

    Published data on carbenium ions containing carbon-carbon triple bonds both directly conjugated with the carbenium centre and separated from it are surveyed and described systematically. Ammonium, diazonium, iminium, phosphonium and iodonium cations containing alkynyl groups, which can be regarded as heteroanalogues of alkynylcarbenium ions, are also considered. The bibliography includes 283 references

  14. High-quality laser-accelerated ion beams for medical applications

    Energy Technology Data Exchange (ETDEWEB)

    Harman, Zoltan; Keitel, Christoph H. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Salamin, Yousef I. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); American University of Sharjah (United Arab Emirates)

    2009-07-01

    Cancer radiation therapy requires accelerated ion beams of high energy sharpness and a narrow spatial profile. As shown recently, linearly and radially polarized, tightly focused and thus extremely strong laser beams should permit the direct acceleration of light atomic nuclei up to energies that may offer the potentiality for medical applications. Radially polarized beams have better emittance than their linearly polarized counterparts. We put forward the direct laser acceleration of ions, once the refocusing of ion beams by external fields is solved or radially polarized laser pulses of sufficient power can be generated.

  15. On the energy crisis in the Io plasma torus

    Science.gov (United States)

    Smith, Robert A.; Bagenal, Fran; Cheng, Andrew F.; Strobel, Darrell

    1988-01-01

    Recent calculations of the energy balance of the Io plasma torus show that the observed UV and EUV radiation cannot be maintained solely via energy input by the ion pickup mechanism. Current theoretical models of the torus must be modified to include non-local energy input. It is argued that the required energy may be supplied by inward diffusion of energetic heavy ions with energies less than about 20 keV.

  16. Development of Electrically Switched Ion Exchange Process for Selective Ion Separations

    International Nuclear Information System (INIS)

    Rassat, Scot D.; Sukamto, Johanes H.; Orth, Rick J.; Lilga, Michael A.; Hallen, Richard T.

    1999-01-01

    The electrically switched ion exchange (ESIX) process, being developed at Pacific Northwest National Laboratory, provides an alternative separation method to selectively remove ions from process and waste streams. In the ESIX process, in which an electroactive ion exchange film is deposited onto a high surface area electrode, uptake and elution are controlled directly by modulating the electrochemical potential of the film. This paper addresses engineering issues necessary to fully develop ESIX for specific industrial alkali cation separation challenges. The cycling and chemical stability and alkali cation selectivity of nickel hexacyanoferrate (NiHCF) electroactive films were investigated. The selectivity of NiHCF was determined using cyclic voltammetry and a quartz crystal microbalance to quantify ion uptake in the film. Separation factors indicated a high selectivity for cesium and a moderate selectivity for potassium in high sodium content solutions. A NiHCF film with improved redox cycling and chemical stability in a simulated pulp mill process stream, a targeted application for ESIX, was also prepared and tested

  17. Longitudinal dynamics of laser-cooled fast ion beams

    DEFF Research Database (Denmark)

    Weidemüller, M.; Eike, B.; Eisenbarth, U.

    1999-01-01

    We present recent results of our experiments on laser cooling of fast stored ion beams at the Heidelberg Test Storage Ring. The longitudinal motion of the ions is directly cooled by the light pressure force, whereas efficient transverse cooling is obtained indirectly by longitudinal-transverse co......We present recent results of our experiments on laser cooling of fast stored ion beams at the Heidelberg Test Storage Ring. The longitudinal motion of the ions is directly cooled by the light pressure force, whereas efficient transverse cooling is obtained indirectly by longitudinal....... When applying laser cooling in square-well buckets over long time intervals, hard Coulomb collisions suddenly disappear and the longitudinal temperature drops by about a factor of three. The observed longitudinal behaviour of the beam shows strong resemblance with the transition to an Coulomb...

  18. Influence of chromatin condensation on the number of direct DSB damages induced by ions studied using a Monte Carlo code

    International Nuclear Information System (INIS)

    Dos Santos, M.; Clairand, I.; Gruel, G.; Barquinero, J.F.; Villagrasa, C.; Incerti, S.

    2014-01-01

    The purpose of this work is to evaluate the influence of the chromatin condensation on the number of direct double-strand break (DSB) damages induced by ions. Two geometries of chromosome territories containing either condensed or de-condensed chromatin were implemented as biological targets in the Geant4 Monte Carlo simulation code and proton and alpha irradiation was simulated using the Geant4-DNA processes. A DBSCAN algorithm was used in order to detect energy deposition clusters that could give rise to single-strand breaks or DSBs on the DNA molecule. The results of this study show an increase in the number and complexity of DNA DSBs in condensed chromatin when compared with de-condensed chromatin. This work aims to evaluate the influence of the chromatin condensation in the number and complexity of direct DSB damages induced by proton and alpha irradiation. With the simulations of this study, the increase in the number and complexity of DSB-like clusters induced by ions in the heterochromatin when compared with euchromatin regions of the cell nucleus has been observed and quantified. These results suggest that condensed chromatin can be the location of more severe radiation-induced lesions, more difficult to repair, than de-condensed chromatin. On the other hand, it was also observed that, whatever the chromatin condensation, more possible damages are found after proton irradiation compared with alpha particles of the same LET. Nevertheless, as already remarked, this study concerns only the direct effect of ionising radiation that can be calculated from the results of the physical stage simulated with Geant4-DNA. To include indirect effects induced by radicals around the DNA molecule, the elements needed for simulating the chemical stage are being developed in the frame of the Geant4-DNA project(15, 16) and they are planned to be included in future work. With a complete calculation (direct + indirect damages) it would then be possible to estimate an energy

  19. Direct probe of the bent and linear geometries of the core-excited Renner-Teller pair states by means of the triple-ion-coincidence momentum imaging technique

    International Nuclear Information System (INIS)

    Muramatsu, Y.; Ueda, K.; Chiba, H.; Saito, N.; Lavollee, M.; Czasch, A.; Weber, T.; Jagutzki, O.; Schmidt-Boecking, H.; Moshammer, R.; Becker, U.; Kubozuka, K.; Koyano, I.

    2002-01-01

    The doubly degenerate core-excited Π state of CO 2 splits into two due to static Renner-Teller effect. Using the triple-ion-coincidence momentum imaging technique and focusing on the dependence of the measured quantities on the polarization of the incident light, we have probed, directly and separately, the linear and bent geometries for the B 1 and A 1 Renner-Teller pair states, as a direct proof of the static Renner-Teller effect

  20. Ion-ion dynamic structure factor, acoustic modes, and equation of state of two-temperature warm dense aluminum

    Science.gov (United States)

    Harbour, L.; Förster, G. D.; Dharma-wardana, M. W. C.; Lewis, Laurent J.

    2018-04-01

    The ion-ion dynamical structure factor and the equation of state of warm dense aluminum in a two-temperature quasiequilibrium state, with the electron temperature higher than the ion temperature, are investigated using molecular-dynamics simulations based on ion-ion pair potentials constructed from a neutral pseudoatom model. Such pair potentials based on density functional theory are parameter-free and depend directly on the electron temperature and indirectly on the ion temperature, enabling efficient computation of two-temperature properties. Comparison with ab initio simulations and with other average-atom calculations for equilibrium aluminum shows good agreement, justifying a study of quasiequilibrium situations. Analyzing the van Hove function, we find that ion-ion correlations vanish in a time significantly smaller than the electron-ion relaxation time so that dynamical properties have a physical meaning for the quasiequilibrium state. A significant increase in the speed of sound is predicted from the modification of the dispersion relation of the ion acoustic mode as the electron temperature is increased. The two-temperature equation of state including the free energy, internal energy, and pressure is also presented.