WorldWideScience

Sample records for direct immunoradiometric assay

  1. Serum gonadotropins levels in childhood. Critical comparison between immunoradiometric assays and radioimmunoassays

    Energy Technology Data Exchange (ETDEWEB)

    Hertogh, R. De; Vankrieken, L. (Physiology of Human Reproduction Research Unit, University of Louvain, School of Medicine, Brussels (Belgium)); Wolter, R.; Vliet, G. Van (Hopital Universitaire des Enfants, Reine Fabiola, Free University of Brussels (Belgium))

    1989-01-01

    The complex changes in serum LH and FSH levels from infancy to adulthood are diversely evaluated by radioimmunoassays or bioassays. The relative lack of sensitivity and specificity of radioimmunoassay, using polyclonal antibodies, could possibly be overcome by new immunoradiometric assays, using specific antibodies to LH and FSH. Significant differences were indeed observed between radioimmunoassays and immunoradiometric assays. During the prepubertal period, LH levels, measured by the immunoradiometric assays, were below the sensitivity of the method in the majority of the samples. LH levels were, however, well detectable when measured with radioimmunoassay, showing the heterogeneity of circulating LH structures. At the onset of puberty, LH levels increased at least 3 to 4 times in both sexes, when measured with immunoradiometric assays, whereas their increase was only 20 to 60% with the radioimmunoassays. FSH levels remained well detectable in the prepubertal period whether measured by immunoradiometric or radioimmunoassays. At pubertal onset, FSH increase in both sexes was more important in the immunoradiometric assays. The results obtained with immunoradiometric assays give a better insight into the quantitative and qualitative function of the gonadotropes during childhood. The almost complete absence of LH during the prepubertal period and the steep increase at the onset of puberty better reflects the reported data obtained with bioassays. The persistance of significant levels of FSH in the prepubertal ages, and the lesser increase at the onset of puberty, when compared with LH, illustrates that the individual regulation of LH and FSH secretion vary over time and is influenced by developmental factors. (author).

  2. Development of versatile universal reagent immunoradiometric assay technique

    International Nuclear Information System (INIS)

    Hazra, D.K.

    1982-10-01

    Immunoradiometric assays, which make use of labelled antibodies, potentially offer better sensitivity and specificity than do radioimmunoassays, which use labelled antigens. In addition, they can in principle be performed in a particularly convenient scheme wherein the same labelled reagent may be used for many different analytes - thus serving as a ''universal'' labelled reagent. Thus if the specific antibody for every analyte is raised in rabbits, and an anti-rabbit antibody is labelled, the latter may be added after the specific antibody to quantify the amount of specific antibody bound to analyte and thereby the amount of analyte present. The potential greater sensitivity and specificity of the immunoradiometric procedure, coupled with the potential convenience of the ''universal'' labelled reagent, might allow such immunoradiometric techniques to be used effectively in the study of communicable diseases in developing countries. Development of these procedures was the subject of this investigation. Many components of these procedures had to be explored and provisionally optimized, including coating of assay tubes with ''extraction'' antibody, immunological purification of antibodies, labelling of antibodies, and intermediate steps toward these goals. Applications were thereupon tested using those provisionally optimized components. The ''universal'' labelled reagent, a donkey anti-rabbit antiserum, was successfully used in the assay of TSH; however, cross reactions of the reagent with non-rabbit immunoglobulins and other materials present seriously limited the sensitivity of the method. Using conventional immunoradiometric procedures, circulating TB and amoebic antibodies could be detected in patients suffering from these diseases. Similarly, circulating antigens in the same patients could also be detected, but not with sufficient sensitivity and specificity to provide a reliable analytical system. Numerous improvements will be required before these techniques

  3. Two-site immunoradiometric assay for the MB isoenzyme of creatine kinase

    Energy Technology Data Exchange (ETDEWEB)

    Willson, V J.C.; Jones, H M; Thompson, R J [Cambridge Univ. (UK). Clinical School

    1981-06-18

    A two-site immunoradiometric assay for myocardial creatine kinase MB isoenzyme is described. The method utilizes immobilized anti-human creatine kinase BB antibodies and /sup 125/I-labelled anti-human creatine kinase MM antibodies and can specifically detect creatine kinase MB in the presence of approximately 1000-fold excess of creatine kinase MM or BB. Native kinase MB prepared from human heart and creatine kinase MB prepared by hybridisation of purified human creatine kinase MM and creatine kinase BB appeared to react identically in the assay. Serum estimations on patients with suspected myocardial infarction correlated with the presence of MB band on electrophoresis but preliminary results suggest that the two-site immunoradiometric assay may be more sensitive.

  4. A two-site immunoradiometric assay for the MB isoenzyme of creatine kinase

    International Nuclear Information System (INIS)

    Willson, V.J.C.; Jones, H.M.; Thompson, R.J.

    1981-01-01

    A two-site immunoradiometric assay for myocardial creatine kinase MB isoenzyme is described. The method utilizes immobilized anti-human creatine kinase BB antibodies and 125 I-labelled anti-human creatine kinase MM antibodies and can specifically detect creatine kinase MB in the presence of approximately 1000-fold excess of creatine kinase MM or BB. Native kinase MB prepared from human heart and creatine kinase MB prepared by hybridisation of purified human creatine kinase MM and creatine kinase BB appeared to react identically in the assay. Serum estimations on patients with suspected myocardial infarction correlated with the presence of MB band on electrophoresis but preliminary results suggest that the two-site immunoradiometric assay may be more sensitive. (Auth.)

  5. Immunological measurements on the disappearance of creatine kinase MM from the circulation. [Immunoradiometric assay

    Energy Technology Data Exchange (ETDEWEB)

    Wevers, R A; van Landeghem, A A.J.; Mul-Steinbusch, M W.F.J.; Bijdendijk, J G; Weerts, P; Kloeg, P; Soons, J B.J. [Rijksuniversiteit Utrecht (Netherlands)

    1983-07-15

    Both a two-site immunoradiometric assay and a two-site enzyme-linked immunosorbent assay for creatine kinase MM are described. Linearity, reproducibility and cross-reactivity of the assays are satisfactory. Creatine kinase MM incubated in a pH-controlled serum matrix loses its activity, but has its antigenic determinants affected as well. Of all the techniques used, only the immunoradiometric assay is capable of measuring part of the inactivated enzyme. Measurements with this assay on the sera of patients after a myocardial infarction show identical results for enzyme activity and creatine kinase protein quantity. The in vitro disappearance rate of creatine kinase activity is slow compared with the in vivo half-life of the enzyme. These two observations lead to the conclusion that creatine kinase is removed from the circulation long before it is inactivated in the blood stream.

  6. Establishment of immunoradiometric assay for free prostate-specific antigen

    International Nuclear Information System (INIS)

    Ma Lianxue

    2009-01-01

    An immunoradiometric assay (IRMA) of free prostate specific antigen (F-PSA) in serum was established. One monoclonal antibody against total PSA (T-PSA) was coated on the plastic tubes, the other against F-PSA was labeled with 125 I. The sensitivity of assay was 0.04 μg/L (n=20, +2s), the CVs were 2.9%-4.0% for the intra-assay and 3.5%-10.5% for the inter-assay and the average recovery was 102.7%. The correlative equation comparing with the FPSA-RIA (CIS BIO) is y=0.965 1 χ -0.001 1, and r=0.996 4. This F-PSA IRMA is a sensitive and precise method in detecting F-PSA and fit for the vitro assay. (authors)

  7. Radioimmunoassays and 2-site immunoradiometric "sandwich" assays: basic principles.

    Science.gov (United States)

    Rodbard, D

    1988-10-01

    The "sandwich" or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.

  8. Radioimmunoassays and 2-site immunoradiometric 'sandwich' assays: basic principles

    Energy Technology Data Exchange (ETDEWEB)

    Rodbard, D

    1988-10-01

    The 'sandwich' or noncompetitive reagent-excess, 2-site immunoradiometric assay (2-site IRMA), ELISA, USERIA, and related techniques, have several advantages compared with the traditional or competitive radioimmunoassays. IRMAs can provide improved sensitivity and specificity. However, IRMAs present some practical problems with nonspecific binding, increased consumption of antibody, biphasic dose response curve, (high dose hook effect), and may require special techniques for dose response curve analysis. We anticipate considerable growth in the popularity and importance of 2-site IRMA.

  9. Immunoradiometric assay for cytomegalovirus-specific IgG antibodies

    International Nuclear Information System (INIS)

    Klapper, P.E.; Cleator, G.M.; Prinja-Wolks, D.; Morris, D.J.

    1990-01-01

    An immunoradiometric assay (radio-immunosorbent test; RIST) for the detection of IgG antibodies to human herpesvirus 4 [human cytomegalovirus (CMV)] has been developed. The technique utilizes CMV antigen passively adsorbed to a polyvinyl microtitration plate and a radiolabelled murine monoclonal anti-human IgG antibody to detect binding of human antibody to the 'solid phase' reagent. The assay was optimized, and its specifity confirmed by testing paired acute and convalescent sera from patients with acute CMV or other human herpesvirus infections. To determine the assay's sensitivity 1433 blood donor sera were examined. The RIST was more sensitive than a standard complement fixation (CFT). Use of a monoclonal anti-human IgG antibody in the RIST reduced non-specific binding to the control uninfected cell antigen such that blood donor sera could be tested in the assay using only a CMV antigen without generating an unacceptable false positive rate. (author). 23 refs.; 1 tab

  10. Direct measurement of the precursors of adrenocorticotropin in human plasma by two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Crosby, S.R.; Stewart, M.F.; Ratcliffe, J.G.; White, A.

    1988-01-01

    An immunoradiometric assay (IRMA) for the direct measurement of the precursors of ACTH in unextracted human plasma has been developed and evaluated clinically in normal subjects and patients with disorders of the hypothalamic-pituitary-adrenal axis. The IRMA is based on an iodinated monoclonal antibody to ACTH and a monoclonal antibody to gamma MSH coupled to Sephacryl S300. The assay detects only peptides containing both epitopes, i.e. POMC (31K) and pro-ACTH (22K). The reference standard was partially purified POMC from culture medium of human corticotroph adenoma cells. The detection limit (greater than +2.5SD of the 0 standard) was 2.0 pmol/L and the within-assay coefficient of variation was less than 10% between 29 and 2600 pmol/L. Plasma concentrations of ACTH precursor peptides in 11 normal subjects sampled at 0930 h ranged from 5-34 pmol/L. The concentrations in the patient groups studied were: 260-2300 pmol/L in 5 patients with the ectopic ACTH syndrome associated with small cell lung cancer, less than 2.0-104 pmol/L in 10 patients with pituitary-dependent Cushing's disease, 23 pmol/L in a patient with Nelson's syndrome, and 3.0-230 pmol/L in 5 patients with Addison's disease. We conclude that this IRMA offers a simple and reliable method for measuring ACTH precursors in unextracted plasma. The proportionately greater elevation of ACTH precursors compared to ACTH in patients with the ectopic ACTH syndrome associated with small cell lung cancer but not in pituitary-dependent Cushing's syndrome, suggests that this assay may be clinically useful

  11. Isotopic methods or immuno diagnosis: The Radioimmunoassay and immunoradiometric assay

    International Nuclear Information System (INIS)

    Caso, R.

    1997-01-01

    This work offers an explanation about the more used isotopic techniques for immuno diagnosis: the radioimmunoassay (RIA) and immunoradiometric assay (IRMA). It describes the basic principles of these assays, the antigen-antibody reaction, the radioiodination methods with I-125 for antigens and antibodies, the purification and characterization of labelled compounds. On the order hand they present work gives a review of the methods for separate the bound and free fractions. At the end it offers the principles of the quality control of immunoassay and the future lines of research in the field of RIA and IRMA

  12. The evaluation of domestic immunoradiometric assay kit for alpha-fetoprotein

    International Nuclear Information System (INIS)

    Won, Kyoung Sook; Ryu, Jin Sook; Moon, Dae Hyuk; Lee, Hee Kyung

    2000-01-01

    Although α-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for α-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for α-fetoprotein (Riakey AFP IRMA CT R , Sin-Jin Medics, Seoul, Korea). We evaluated intra-and inter-assay precision, recovery rate, parallelism, and sensitivity of serum α-fetoprotein measurement using Riakey AFP IRMA CT R kit. The values of α-fetoprotein measured by Riakey AFP IRMA CT R kit were compared with those measured by two foreign commercial kits (α-fetoproteina of Radim and α-feto.riabead of Abbott). Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within 100±10%. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of α-fetoprotein by Riakey AFP IRMA CT R and that by two foreign commercial kits(r=3D0.98). The first Korean domestic immunoradiometric kit for α-fetoprotein, Riakey AFP IRMA CT R , performed well for clinical use.=20

  13. Immunoradiometric assay for prolactin in serum and tissue; Comparison with radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Ohnami, Shumpei; Nakata, Hajime; Eto, Sumiya (University of Occupational and Environmental Health Hospital, Kitakyushu, Fukuoka (Japan))

    1990-09-01

    Prolactin (PRL) concentrations in sera and tumors of patients with various pituitary tumors were measured by both immunoradiometric assay (IRMA) and radioimmunoassay (RIA). PRL concentrations in sera and tumor tissues measured by IRMA were well correlated with those measured by RIA. PRL concentrations in sera reflected those of tumors removed. This IRMA is a simple and useful method for PRL determination in serum and tissue. (author).

  14. Fundamental and clinical evaluation of ''SCC RIABEAD'' kit for immunoradiometric assay of squamous cell carcinoma related antigen

    International Nuclear Information System (INIS)

    Koizumi, Mitsuru; Endo, Keigo; Nakajima, Kotoko

    1987-01-01

    A commercial ''SCC RIABEAD'' kit for immunoradiometric assay of squamous cell carcinoma related antigen (SCC antigen) was fundamentally and clinically evaluated. Laboratory performance was satisfactory for intra-assay and inter-assay reproducibility, recovery, and dilution, with rapid and simple measurement techniques. Seropositivity for SCC antigen was significantly higher for squamous cell carcinoma of the liver and uterine cervix than the other histology types. In the case of cervical squamous cell carcinoma, it increased with progressing disease. Post-treatment serum levels of SCC antigen returned to negative. SCC antigen is considered to be a useful tumor marker for these diseases. There was a good correlation between the measurement values obtained from the present and conventional (SCC RIAKIT) assays. The present assay remarkably decreased false-positive cases of pulmonary benign diseases. The results showed a ''SCC RIABEAD'' to be a favorable kit for immunoradiometric assay of SSC antigen, as compared with conventional assay kit. (Namekawa, K.)

  15. A sensitive immunoradiometric assay for the detection of hepatitis B surface antigen

    International Nuclear Information System (INIS)

    Cameron, C.H.; Combridge, B.S.; Howell, D.R.; Barbara, J.A.J.

    1980-01-01

    A solid-phase immunoradiometric assay for hepatitis B surface antigen is described which has been in use since 1972. Initially it was used for reference laboratory work, but from 1974 it has also been used for screening blood and blood products. Methods for the production of reagents and their use in blood transfusion and reference work, are outlined. (Auth.)

  16. The evaluation of domestic immunoradiometric assay kit for alpha-fetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Won, Kyoung Sook; Ryu, Jin Sook; Moon, Dae Hyuk; Lee, Hee Kyung [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of)

    2000-08-01

    Although {alpha}-fetoprotein is one of the most commonly used tumor markers in Korea, most of the radioimmunoassay kits for {alpha}-fetoprotein have been imported from foreign countries. The purpose of this study was to evaluate the performance of a recently developed domestic immunoradiometric kit for {alpha}-fetoprotein (Riakey AFP IRMA CT{sup R}, Sin-Jin Medics, Seoul, Korea). We evaluated intra-and inter-assay precision, recovery rate, parallelism, and sensitivity of serum {alpha}-fetoprotein measurement using Riakey AFP IRMA CT{sup R} kit. The values of {alpha}-fetoprotein measured by Riakey AFP IRMA CT{sup R} kit were compared with those measured by two foreign commercial kits ({alpha}-fetoproteina of Radim and {alpha}-feto.riabead of Abbott). Intra-assay coefficients of variation on three different levels were 5.3% for 18.9 ng/ml, 3.4% for 133 ng/ml and 1.6% for 330 ng/ml. Inter-assay coefficients of variation were 9.7% for 20.9 ng/ml, 3.2% for 137 ng/ml and 4.1% for 330 ng/ml respectively. Recovery rate tests on all three different levels showed within 100{+-}10%. Parallelism was also good and the sensitivity was 0.63 ng/ml. There was strong correlation between the measurement of {alpha}-fetoprotein by Riakey AFP IRMA CT{sup R} and that by two foreign commercial kits(r=3D0.98). The first Korean domestic immunoradiometric kit for {alpha}-fetoprotein, Riakey AFP IRMA CT{sup R}, performed well for clinical use.

  17. Evaluation of immunoradiometric and ELISA versions of a microtitre plate assay for Bacillus anthracis spores

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, A P; Martin, K L; Cross, N L [Chemical Defence Experimental Establishment, Porton (UK); Drake, R G [Glasgow Univ. (UK). Inst. of Biochemistry

    1984-05-11

    Solid-phase indirectly-labelled antibody assays for Bacillus anthracis spores heat-fixed on polystyrene microtitre plates were compared as immunoradiometric assay (IRMA) and enzyme-linked immunosorbent assay (ELISA) versions. Signal-to-noise ratios were usually higher in the IRMA than in the ELISA performed under parallel conditions but replicates were more varied in the IRMA. The antigen detection threshold and resolution limit calculated after regression analysis were broadly comparable in the 2 types of assay.

  18. Novel immunoradiometric assay of thyroglobulin in serum with use of monoclonal antibodies selected for lack of cross-reactivity with autoantibodies

    International Nuclear Information System (INIS)

    Piechaczyk, M.; Baldet, L.; Pau, B.; Bastide, J.M.

    1989-01-01

    A multisite immunoradiometric assay for measurement of serum thyroglobulin (Tg), designated Magnogel-IRMA-Tg, has been developed, involving magnetic microbeads (Magnogel). This assay is based on the use of five anti-Tg monoclonal antibodies (MAbs) directed against three antigenic regions on the Tg molecule that are not recognized by anti-Tg autoantibodies (aAbs). Four of these MAbs, directed against two antigenic domains, were coupled to the magnetic beads and were used to trap the serum antigen. Another MAb, directed against the third region, was iodinated and served as the labeled second antibody. The Magnogel-IRMA-Tg technique is reproducible, rapid, and sensitive (lower detection limit, 3 micrograms/L). The assay reliably measures serum Tg in the presence of anti-Tg aAbs

  19. Automated immunoradiometric assay of thyrotrophin (TSH) in dried blood filter paper spots

    Energy Technology Data Exchange (ETDEWEB)

    John, R.; Woodhead, J.S. (Welsh National School of Medicine, Cardiff (UK))

    1982-11-10

    An immunoradiometric two-site assay for thyrotrophin (TSH) in dried blood filter paper spots is described. The assay is automated by means of the Kemtek 3000 automated immunoassay system. The technique uses a 6.0 mm disc punched from the dried blood samples collected as part of the screening programme for phenylketonuria. The method is sensitive and precise, and results correlate well with those obtained in TSH assays of serum samples. The procedure is rapid, results being available within 24 h of receipt of samples. Of 25204 specimens so far screened by this assay, 99.9% have TSH levels less than 15 mU/l. One false positive result has been obtained and six confirmed cases of neonatal hypothyroidism detected, giving a prevalence of 1 in 4200.

  20. Study of serum TSH content in functioning thyroid gland adenoma by 'supersensitive' immunoradiometric assay

    International Nuclear Information System (INIS)

    Foeldes, Janos; Banos, Csaba; Csillag, Jozsef; Lakatos, Peter; Tarjan, Gabor; 2546970HU)

    1987-01-01

    Determinations of serum TSH levels by immunoradiometric assay (IRMA)-math TSH (Mallinckrodt) kit and of the thyroid function by scintiscanning using 99m Tc-pertechnetate (20-40 MBq) were carried out paralelly in euthyroid and hyperthyroid patients. A comparison of the two tests allowed a better distinction of preclinical hyperthyreosis from toxic adenomas. (L.E.)

  1. Antibodies to poliovirus detected by immunoradiometric assay with a monoclonal antibody

    International Nuclear Information System (INIS)

    Spitz, M.; Fossati, C.A.; Schild, G.C.; Spitz, L.; Brasher, M.

    1982-01-01

    An immunoradiometric assay (IRMA) for the assay of antibodies to poliovirus antigens is described. Dilutions of the test sera or whole (finger prick) blood samples were incubated with the poliovirus antigen bound to a solid phase and the specific antibody was detected by the addition of a mouse anti-human IgG monoclonal antibody (McAb), which was itself revealed by iodinated sheep IgG antimouse F(ab). The authors have shown that this technique is suitable for the estimation of IgG anti-poliovirus antibodies induced in children following polio vaccine. The present study shows that SPRIA provides a simple and inexpensive method for serological studies with poliovirus particularly for use in large-scale surveys. (Auth.)

  2. Antibodies to poliovirus detected by immunoradiometric assay with a monoclonal antibody

    Energy Technology Data Exchange (ETDEWEB)

    Spitz, M.; Fossati, C.A.; Schild, G.C.; Spitz, L.; Brasher, M. (National Inst. for Biological Standards and Control, London (UK))

    1982-10-01

    An immunoradiometric assay (IRMA) for the assay of antibodies to poliovirus antigens is described. Dilutions of the test sera or whole (finger prick) blood samples were incubated with the poliovirus antigen bound to a solid phase and the specific antibody was detected by the addition of a mouse anti-human IgG monoclonal antibody (McAb), which was itself revealed by iodinated sheep IgG antimouse F(ab). The authors have shown that this technique is suitable for the estimation of IgG anti-poliovirus antibodies induced in children following polio vaccine. The present study shows that SPRIA provides a simple and inexpensive method for serological studies with poliovirus particularly for use in large-scale surveys.

  3. Direct measurement of human plasma corticotropin-releasing hormone by two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Linton, E.A.; McLean, C.; Nieuwenhuyzen Kruseman, A.C.; Tilders, F.J.; Van der Veen, E.A.; Lowry, P.J.

    1987-01-01

    A ''two-site'' immunoradiometric assay (IRMA) which allows the direct estimation of human CRH (hCRH) in plasma is described. Using this IRMA, basal levels of CRH in normal subjects ranged from 2-28 pg/mL [mean, 15 +/- 7 (+/- SD) pg/mL; n = 58]. Values in men and women were similar. Plasma CRH values within this range were also found in patients with Cushing's syndrome, Addison's disease, and Nelson's syndrome, with no correlation between plasma CRH and ACTH levels in these patients. Elevated plasma CRH levels were found in pregnant women near term [1462 +/- 752 (+/- SD) pg/mL; n = 55], and the dilution curve of this CRH-like immunoreactivity paralleled the IRMA standard curve. After its immunoadsorption from maternal plasma, this CRH-like material eluted on reverse phase high performance liquid chromatography with a retention time identical to that of synthetic CRH and had equipotent bioactivity with the synthetic peptide in the perfused anterior pituitary cell bioassay. Circulating CRH was not detected in Wistar rats, even after adrenalectomy and subsequent ether stress. Synthetic hCRH was degraded by fresh human plasma relatively slowly; 65% of added CRH remained after 1 h of incubation at 37 C. Degradation was inhibited by heat treatment (54 C; 1 h), cold treatment (4 C; 4 h), or freezing and thawing. Loss of synthetic rat CRH occurred more rapidly when fresh rat plasma was used; only 20% of added CRH remained under the same conditions. The inability to measure CRH in peripheral rat plasma may be due to the presence of active CRH-degrading enzymes which fragment the CRH molecule into forms not recognized by the CRH IRMA

  4. Measurement of human tissue-type plasminogen activator by a two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Rijken, D.C.; Juhan-Vague, I.; De Cock, F.; Collen, D.

    1983-01-01

    A two-site immunoradiometric assay for human extrinsic (tissue-type) plasminogen activator was developed by using rabbit antibodies raised against plasminogen activator purified from human melanoma cell culture fluid. Samples of 100 μl containing 1 to 100 ng/ml plasminogen activator were incubated in the wells of polyvinyl chloride microtiter plates coated with antibody. The amount of bound extrinsic plasminogen activator was quantitated by the subsequent binding of 125 I-labeled affinospecific antibody. The mean level of plasma samples taken at rest was 6.6 +/- 2.9 ng/ml (n = 54). This level increased approximately threefold by exhaustive physical exercise, venous occlusion, or infusion of DDAVP. Extrinsic plasminogen activator in plasma is composed of a fibrin-adsorbable and active component (1.9 +/- 1.1 ng/ml, n = 54, in resting conditions) and an inactive component that does not bind to a fibrin clot (probably extrinsic plasminogen activator-proteinase inhibitor complexes). The fibrin-adsorbable fraction increased approximately fivefold to eightfold after physical exercise, venous occlusion, or DDAVP injections. Potential applications of the immunoradiometric assay are illustrated by the measurement of extrinsic plasminogen activator in different tissue extracts, body fluids, and cell culture fluids and in oocyte translation products after injection with mRNA for plasminogen activator

  5. Development of a new in vivo kit for detection of prostate specific antigen in human serum using immunoradiometric assay method

    International Nuclear Information System (INIS)

    Babaei, M. H.; Behradkia, P.; Shafii, M.; Movla, M.; Forutan, H.; Najafi, R.

    2006-01-01

    Prostate is a leading site for the cancer incidence, accounted for 31.0% of new cancer cases in men. Prostate-specific antigen is widely used in the detection and monitoring of the prostate cancer. Currently, immunoassay is used to detect Prostate-specific antigen in human serum. This technique is based on the interaction between antibody and antigen. The varied immunoassay formats and equipment to run the assays allow the users to measure the analytes rapidly, with the flexibility to run a small or a large number of samples. Among different immunoassay methods, immunoradiometric assay is a more sensitive and valuable detection approach. This study has been made in 4 parts: (1) purification of Prostate-specific antigen from seminal fluid; (2) preparation of hybridoma cells which secrete monoclonal antibody (mAb) against Prostate-specific antigen , (3) selection of pair monoclonal antibody among those antibodies, and finally (4) design of an immunoradiometric assay kit and it's quality control . The results of this study were: (1) obtaining a huge amount of Prostate-specific antigen as semi-purified and purified, that is a valuable material for preparation of standard kits; (2) preparation of 8 kinds of monoclonal antibodies; (3) finding 4 pairs of monoclonal antibodies which react with different epitopes on Prostate-specific antigen molecule; and (4) preparation of immunoradiometric assay kit for measuring Prostate-specific antigen concentration in human serum

  6. Immunoradiometric assay for cytomegalovirus-specific IgG antibodies; Assay development and evaluation in blood transfusion practice

    Energy Technology Data Exchange (ETDEWEB)

    Klapper, P.E.; Cleator, G.M.; Prinja-Wolks, D.; Morris, D.J. (Medical School, Manchester (United Kingdom). Department of Medical microbiology, Virology Unit); Morell, G. (Regional Blood Transfusion Centre, manchester (United Kingdom))

    1990-03-01

    An immunoradiometric assay (radio-immunosorbent test; RIST) for the detection of IgG antibodies to human herpesvirus 4 (human cytomegalovirus (CMV)) has been developed. The technique utilizes CMV antigen passively adsorbed to a polyvinyl microtitration plate and a radiolabelled murine monoclonal anti-human IgG antibody to detect binding of human antibody to the 'solid phase' reagent. The assay was optimized, and its specifity confirmed by testing paired acute and convalescent sera from patients with acute CMV or other human herpesvirus infections. To determine the assay's sensitivity 1433 blood donor sera were examined. The RIST was more sensitive than a standard complement fixation (CFT). Use of a monoclonal anti-human IgG antibody in the RIST reduced non-specific binding to the control uninfected cell antigen such that blood donor sera could be tested in the assay using only a CMV antigen without generating an unacceptable false positive rate. (author). 23 refs.; 1 tab.

  7. An automated immunoradiometric assay of thyrotrophin (TSH) in dried blood filter paper spots

    International Nuclear Information System (INIS)

    John, R.; Woodhead, J.S.

    1982-01-01

    An immunoradiometric two-site assay for thyrotrophin (TSH) in dried blood filter paper spots is described. The assay is automated by means of the Kemtek 3000 automated immunoassay system. The technique uses a 6.0 mm disc punched from the dried blood samples collected as part of the screening programme for phenylketonuria. The method is sensitive and precise, and results correlate well with those obtained in TSH assays of serum samples. The procedure is rapid, results being available within 24 h of receipt of samples. Of 25204 specimens so far screened by this assay, 99.9% have TSH levels less than 15 mU/l. One false positive result has been obtained and six confirmed cases of neonatal hypothyroidism detected, giving a prevalence of 1 in 4200. (Auth.)

  8. Immunoradiometric assay for ferritin in human serum

    International Nuclear Information System (INIS)

    Leyland, M.J.; Ganguli, P.C.; Blower, D.; Delamore, I.W.

    1975-01-01

    A sensitiv specific and precise immunoradiometric assay for ferritin has been developed. Ferritin was measured in the serum of 160 hospital controls, 101 females (118 plus/minus 9 μg/l) and 59 males (189 plus/minus 16 μg/l). This difference was statistically significant. In 28 patients with untreated iron deficiency anemia, serum ferritin concentration (6.1plus/minus 0.7 μg/l) was significantly lower than in the controls, but it was within the normal range in 14 cases of polycythaemia vera treated by repeated phlebotomy. In 4 patients with primary haemachromatosis (2884 plus/minus 56 μg/l), 25 with secondary iron overload states (5702 plus/minus 1235 μg/l) and 8 with haemolytic anaemia (1612 plus/minus 605 μg/l), serum ferritin levels were markedly elevated. In 14 cases of transfusional siderosis there was a highly significant correlation between serum ferritin concentration and units of blood transfused. A circadian rhythmin serum ferritin concentration was observed in 7 healthy subjects. (author)

  9. First field trial of an immunoradiometric assay for the detection of malaria sporozoites in mosquitoes

    International Nuclear Information System (INIS)

    Collins, F.H.; Zavala, F.; Graves, P.M.; Cochrane, A.H.; Gwadz, R.W.; Akoh, J.; Nussenzweig, R.S.

    1984-01-01

    An immunoradiometric assay (IRMA) using a monoclonal antibody to the major surface protein of Plasmodium falciparum sporozoites was used to assess the P. falciparum sporozoite rate in a West African population of Anopheles gambiae (s.1.). Unlike current dissection techniques, the IRMA could detect sporozoite antigen in dried as well as fresh mosquitoes. In a controlled comparison, the sensitivity of the IRMA was comparable that of the dissection technique. Additionally, the IRMA was species specific and quantitative. Sensitivity of the assay was sufficient to detect sporozoite infections resulting from the development of a single oocyst

  10. Development of a second generation monoclonal immunoradiometric assay. Increased sensitivity leads to enhanced detection of hepatitis B viral infection

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, H; Wands, J R; Kameda, H

    1988-09-13

    The authors have developed and employed a second generation monoclonal immunoradiometric assay (M2-IRMA) using antibodies of high affinity for epitopes that reside on hepatitis B surface antigen (HBsAg). This assay is capable of detecting as little as 15 pg/ml of HBsAg in serum. Improvements in sensitivity over a first generation immunoradiometric assay (MI-IRMA) was achieved by increasing the sample volume and time of incubation, and subjecting the reaction to a mechanical rotary device. 164 subjects with chronic hepatitis, 105 with cirrhosis, 67 with hepatocellular carcinoma, six with acute hepatitis A, seven with acute hepatitis B, 167 chronic carriers of hepatitis B virus (HBV) and 235 healthy individuals from Japan were studied and the results of the M2-IRMA were compared to a conventional polyclonal radioimmunoassay (P-RIA). By using a more sensitive assay design (M2-IRMA), a significant number of additional cases of HBV infection heretofore unsuspected in the etiology of chronic liver disease were identified. It is concluded that improvement in assay sensitivity for HBsAg is important in the serologic diagnosis of HBV in patients with chronic hepatitis, cirrhosis and hepatocellular carcinoma. 14 refs.; 6 figs.; 6 tabs.

  11. Measurement of immunoglobulin production by peripheral blood mononuclear cells in vitro using a solid-phase immunoradiometric assay

    International Nuclear Information System (INIS)

    Roffe, L.M.; Maini, R.N.; Cohen, M.L.; Meretey, K.

    1981-01-01

    A simple solid-phase immunoradiometric assay for IgG and IgM is described. Supernatants from lymphocyte cultures are incubated in microtitre plates which have been precoated with anti-IgG or anti-IgM. Subsequent binding of 125 I-labelled anti-immunoglobulin is measured and IgG and IgM in supernatants are estimated from the standard curve constructed for each assay. The assay is specific for human IgG and IgM, is able to detect nanogram amounts and offers advantages over other techniques for evaluating in vitro lymphocyte function. (Auth.)

  12. Immunoradiometric assay of lipid A: a test for detecting and quantitating endotoxins of various origins

    Energy Technology Data Exchange (ETDEWEB)

    Nolan, J P; Vladutiu, A O; Moreno, D M; Cohen, S A; Camara, D S [State University of New York, Buffalo (USA). School of Medicine

    1982-11-26

    The ability to measure circulating endotoxin in various disease states has been hampered by the lack of a specific and quantitative assay. The test most commonly used has been the Limulus gelation assay, which measures an enzymatic effect of endotoxin rather than the substance itself. Based on a solid-phase immunoradiometric assay previously developed to detect the specific lipopolysaccharide from Escherichia coli 026, a similar assay has been developed for the lipid A moiety of endotoxins. The assay uses rabbit antibodies to lipid A which do not react with ketodeoxyoctonate, myristic or beta-hydroxymyristic acids, and detects lipid A obtained from endotoxins of various origins after acid hydrolysis of lipopolysaccharide. Experiments in rats given exogenous endotoxin suggest that this assay can be useful for quantitation of bacterial endotoxins in serum and for studying the pathophysiology of experimental endotoxemia.

  13. Establishment and clinical application of immunoradiometric assay for human growth hormone in serum

    International Nuclear Information System (INIS)

    Ji Jinfeng; Wu Congyuan; Niu Zhanpo; Zhang Kui; Song Ailing; Deng Jieying; Shi Mifan

    1992-01-01

    An immunoradiometric assay (IRMA) for human growth hormone (hGH) in serum is developed based on two high specific monoclonal antibodies against hGh. It can specifically detect the levels of serum bioactive hGh and had no cross-reaction with human prolactin (hPRL) and hGh oligmeric forms. The sensitivity was 0.2 ng/ml and the recovery for different concentrations of hGh was 92.0% ∼ 103.2%. The coefficients of variation for intra and inter-assay were<9.1% and <14.2%, respectively. Integral analysis of the results of RIA and IRMA with the patients' clinical manifestations revealed that hGh IRMA is better than hGh RIA in reflecting the clinical states of different acromegalic patients

  14. Solid-phase immunoradiometric assay for C-reactive protein using magnetisable cellulose particles

    International Nuclear Information System (INIS)

    Beer, F.C. de; Pepys, M.B.

    1982-01-01

    An immunoradiometric assay (IRMA) for C-reactive protein (CRP) was developed using magnetisable cellulose particles as the solid-phase support for anti-CRP antibodies. 125 I-labelled immunopurified anti-CRP antibody was used to quantitate the amount of CRP taken up by the solid phase. Unbound label was easily and rapidly removed by decantation after sedimenting the particles on a magnet. The assay could detect 1 μg CRP/l and had a range of up to 10 mg/l with the portion of the standard curve between 10 μg/l and 2-3 mg/l being linear. Fifty samples per hour could be processed manually from serum to CRP result with an intra-assay CV of 5.2% and an inter-assay CV of 10.0%, based on 5 replicates of 5 samples with CRP levels between 2 mg/l and 180 mg/l run in 5 separate assays. Fifty clinical samples were assayed in parallel with a standard electroimmunoassay and yielded a linear correlation coefficient (r) of 0.975 and a slope of 0.98. With its single, brief incubation step including all reagents and its simple phase separation procedure the present method may be the assay of choice when precise measurement of CRP concentrations is required rapidly. (Auth.)

  15. A new and rapid method for immunoglobulin class and subclass determination of mouse monoclonal antibodies using a solid-phase immunoradiometric assay

    International Nuclear Information System (INIS)

    Storch, M.-J.; Lohmann-Matthes, M.-L.

    1984-01-01

    A solid-phase immunoradiometric assay is described for the detection of mouse immunoglobulin classes and subclasses in unpurified and unconcentrated supernatants of hybridomas. IgG fractions from rabbit antisera specific for mouse immunoglobulin classes and subclasses are used for coating the wells of flexible microtiter plates. Monoclonal antibody present in hybridoma supernatants is bound only to wells that contain the appropriate anti-subclass antibody. The binding of hybridoma antibodies to corresponding IgG subclasses or IgM is then detected by a labeled rabbit anti-mouse antibody binding to all mouse immunoglobulins (heavy and light chains). Thus, only 1 labeled antibody is needed for all assays. The advantages of the method described are the following: results are obtained within a few hours and antibody containing hybridoma supernatants may be used without a concentration step since minute amounts of antibody are detected by the immunoradiometric assay. Cultures producing several subclasses may be early recognized as oligo/polyclonal. (Auth.)

  16. Monoclonal antibodies to human factor VII: a one step immunoradiometric assay for VII:Ag.

    OpenAIRE

    Takase, T; Tuddenham, E G; Chand, S; Goodall, A H

    1988-01-01

    Three mouse monoclonal antibodies (RFF-VII/1, RFF-VII/2, and RFF-VII/3) which bind specifically to different epitopes on human factor VII antigen were raised. Two of the antibodies, RFF-VII/1 and RFF-VII/2, bound strongly to factor VII antigen (VII:Ag), but only RFF-VII/1 and RFF-VII/3 were potent inhibitors of factor VII coagulation activity (VII:C). RFF-VII/1 and RFF-VII/2 were used in a one step, double monoclonal immunoradiometric assay for VII:Ag. This was highly reproducible and detecte...

  17. The effects of variations in the specificities of the antibody components on a two-site immunoradiometric assay for ferritin

    International Nuclear Information System (INIS)

    Cowan, S.I.; Stagg, B.H.; Niemann, E.

    1977-01-01

    Variations in the sub-unit antigenic structure of ferritins derived from various human tissues are reflected in the differing specificities of antisera raised against these ferritin preparations. In this study it was shown that antibody specificity played an important role in determining the sensitivity and overall binding of labelled antibody in a two-site immunoradiometric assay for ferritin. Homologous assay systems, in which solid phase and radiolabelled antibodies were of similar specificities, were generally less sensitive and showed lower binding than heterologous assay systems, in which solid phase and labelled antibodies were of different specificities. The source of the ferritin which was used as assay standard also played an important part in determining the sensitivity and overall binding in homologous antibody systems, spleen ferritin standards yielding assays superior to those obtained with placenta or liver ferritin standards. However, these differences between standards were not seen in a heterologous system employing solid phase antibodies directed against liver ferritin and labelled antibodies directed against placenta ferritin. The nature of the ferritin used to prepare immunoadsorbant for the purification of antibodies prior to radioiodination also affected the assay characteristics; antibodies prepared on spleen ferritin immunoadsorbant being more reactive than antibodies prepared on placenta ferritin immunoadsorbant, which in turn were more reactive then antibodies prepared on liver ferritin immunoadsorbant. (orig.) [de

  18. Use of monoclonal immunoradiometric assays for sensitive TSH measurements: evaluation of four commercially obtainable kits

    International Nuclear Information System (INIS)

    Smitz, J.; Schiettecatte, J.; Stierteghem, A.C. van; Jonckheer, M.H.

    1987-01-01

    Four commerically available monoclonal immunoradiometric methods for the assay of TSH are tested. These four kits are: RIA-GNOST TSH code 0CPL of Behring, SUCROSEP TSH IRMA of Boots, TSH-IRMA-CT-100 of Medgenix, TSH-RIA bead II Ultrasensitive of Abbott. The accuracy, sensitivity and reproducibility of the four kits are compared. The methods are also clinically evaluated. The authors concluded that the kits of Abbott, Behring and Boots are suitable for use in the routine laboratory. 4 refs.; 4 figs.; 7 tabs

  19. A two-site immunoradiometric assay for human pregnancy-associated plasma protein A (PAPP-A) using monoclonal antibodies

    International Nuclear Information System (INIS)

    Mowles, E.A.; Pinto-Furtado, L.G.; Bolton, A.E.

    1986-01-01

    A rapid, sensitive immunoradiometric assay has been developed for human pregnancy-associated plasma protein A (PAPP-A) using a purified mouse monoclonal antibody as the tracer and a rabbit polyclonal antibody to this protein in the solid-phase antibody preparation. The assay showed no measurable cross-reaction (< 0.1%) against a range of purified human placental proteins, and a good correlation with a previously described radioimmunoassay procedure when tested on samples taken throughout normal human pregnancies. No PAPP-A-like immunological activity could be detected in sera from non-pregnant women, confirming the absence of this protein from the circulation outside pregnancy. (Auth.)

  20. An immunoradiometric assay for Helicobacter pylori urease B in serum

    International Nuclear Information System (INIS)

    Bai Yanyan; Wang Zhaoyue; Bai Xia; Ruan Changgen; Miao Jingcheng; Gu Guanbing

    2008-01-01

    Objective: The aim of this study was to establish and evaluate a novel immunoradiometric assay (IRMA) for detecting helicobacter pylori (HP) urease B (ureB) in serum. Methods: HP ureB was prepared by the DNA recombinant technique. Monoclonal antibodies against HP ureB were produced by hybridoma technique and were used to establish IRMA for detecting HP ureB. Fifty patients with chronic gastric diseases were recruited in this study, including 36 with gastric ulcer disease, 9 with chronic gastritis and 5 with gastric cancer. The IRMA was compared with rapid urease test (RUT), polymerase chain reaction (PCR) test and direct-ELISA test of serum anti-ureB antibody, using HP culture from gastric biopsy samples as a 'golden standard'. Results: The sensitivity and specificity of IRMA for HP ureB were 94.6% and 76.9%, respectively, with positive and negative predictive values being 92.1% and 83.3%. The sensitivity and specificity of RUT, PCR and serum anti-ureB antibody test were 94.6% and 23.1% , 66.8% and 84.6%, 86.5% and 38.5%, respectively. IRMA and the test of serum anti-ureB antibody was not significantly different from the 'golden standard' (X 2 =1.165, P>0.05), but RUT and PCR showed statistically significant difference with the 'gold standard' (X 2 =5.333, 9.436; all P<0.05). Conclusion: IRMA for HP ureB antigen is a sensitive and specific method for detection of HP infection, and can be used in the study of etiology and pathogenesis of gastric and some other related diseases. (authors)

  1. Immunoradiometric assay for quantification of serum antibodies to dental plaque antigen in immunized dogs

    International Nuclear Information System (INIS)

    Ahlstedt, S.; Rylander, H.

    1975-01-01

    An immunoradiometric assay (IRMA) was used for quantifying dog serum antibodies to antigens from dental plaque collected from full-grown dogs. The antigens were adsorbed onto the inner surface of plastic tubes and then incubated with dog-anti-plaque serum, 125 I-labelled anti-dog plasma-immunoglobulin was used for quantification of the specific antibodies. Four 10 months old Beagle dogs in excellent gingival health were immunized for 10 weeks with ultrasonicated dog dental plaque. The antibody levels in antisera sampled 6, 8, 10 and 11 weeks after the first antigen injection were 2 to 5 times as high as those recorded before the immunizing period. The variability of the assay as judged from the difference between duplicate samples was found to be 18 percent+-4 (p<0.01) of the mean value and the variability between the same serum ran on different test occasions 13 percent+-7 (p<0.01). The specificity of the antigen-antibody reaction in the immuno assay was tested by inhibition experiments. Preincubation of the antisera with dental plaque antigen significantly inhibited the antigen-antibody reaction in the IRMA, while bovine serum albumin did not. (author)

  2. Immunoradiometric assay for quantification of serum antibodies to dental plaque antigen in immunized dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ahlstedt, S; Rylander, H [Goeteborg Univ. (Sweden)

    1975-01-01

    An immunoradiometric assay (IRMA) was used for quantifying dog serum antibodies to antigens from dental plaque collected from full-grown dogs. The antigens were adsorbed onto the inner surface of plastic tubes and then incubated with dog-anti-plaque serum, /sup 125/I-labelled anti-dog plasma-immunoglobulin was used for quantification of the specific antibodies. Four 10 months old Beagle dogs in excellent gingival health were immunized for 10 weeks with ultrasonicated dog dental plaque. The antibody levels in antisera sampled 6, 8, 10 and 11 weeks after the first antigen injection were 2 to 5 times as high as those recorded before the immunizing period. The variability of the assay as judged from the difference between duplicate samples was found to be 18 percent+-4 (p<0.01) of the mean value and the variability between the same serum ran on different test occasions 13 percent+-7 (p<0.01). The specificity of the antigen-antibody reaction in the immuno assay was tested by inhibition experiments. Preincubation of the antisera with dental plaque antigen significantly inhibited the antigen-antibody reaction in the IRMA, while bovine serum albumin did not.

  3. Two-site sandwich immunoradiometric assay of human lymphotoxin with monoclonal antibodies and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Meager, A; Parti, S; Leung, H; Woolley, J; Peil, E; Sidhu, S; Roberts, T

    1987-11-23

    Three monoclonal antibodies (MoAbs L49-15, L81-11 and L238-14) were raised against recombinant human lymphotoxin (rLT) derived from E. coli containing the cDNA sequence specifying LT. These MoAbs were ideal reagents for immunoassay of LT and a very sensitive, highly specific immunoradiometric assay (IRMA) was developed. This assay was rapid to perform and was capable of detecting as little as 10 pg/ml of LT. Application of the LT IRMA in combination with previously developed human gamma-interferon (IFN-..gamma..) and human tumour necrosis factor (TNF)-specific IRMA permitted independent estimations of these three substances to be carried out in parallel. By these means, it was found that RPMI 1788 lymphoblastoid cell line produced both LT and TNF, but not IFN-..gamma... Extensive analyses on cytokine (monokine and lymphokine) preparations derived from a variety of activated lymphocytes are also reported. Co-production of LT, TNF, and IFN-..gamma.. was a common finding, even occurring in alloantigen-specific T helper cell clones. 45 refs.; 3 figs.; 4 tabs.

  4. Solid-phase immunoradiometric assay for serum amyloid A protein using magnetisable cellulose particles

    International Nuclear Information System (INIS)

    De Beer, F.C.; Dyck, R.F.; Pepys, M.B.

    1982-01-01

    An immunoradiometric assay for human serum amyloid A protein (SAA) was developed using magnetisable cellulose particles as the solid phase. Rabbit antiserum to SAA was raised by immunization with SAA isolated from acute-phase serum by gel filtration in formic acid. The antiserum was rendered monospecific for SAA by solid-phase immunoabsorption with normal human serum, which contains only traces of SAA, and some was coupled covalently to the cellulose particles. Immunopurified anti-SAA antibodies were isolated from the monospecific anti-SAA serum by binding to, and elution from insolubilized acute-phase serum and were radiolabelled with 125 I. The assay was calibrated with an acute phase serum which contained 6000 times more SAA than normal sera with the lowest detectable level of SAA, and an arbitrary value of 6000 U/l was assigned to this standard. Sera were tested in the native, undenatured state and there was no increase in SAA immunoreactivity following alkali treatment or heating. The assay range was from 1-2000 U/l so that all SAA levels above 6 U/l could be measured on a single (1:6) dilution of serum. The intra- and interassay coefficients of variation were 11.7 and 15.0% respectively. Among 100 healthy normal subjects (50 male, 50 female) the median SAA level was 9 U/l, range <1-100, with 93% below 20 U/l and only 2% below the lower limit of sensitivity of the assay (1 U/l). (Auth.)

  5. Monoclonal antibodies for use in an immunoradiometric assay for α-foetoprotein

    International Nuclear Information System (INIS)

    Hunter, W.M.; Bennie, J.G.

    1982-01-01

    The advantages offered by a mouse IgG 1 monoclonal antibody to human α-foetoprotein (AFP) for the preparation of [ 125 I]antibody for use in an immunoradiometric assay (IRMA) have been investigated. The antibody was isolated from ascites fluid by sodium sulphate precipitation followed by gel filtration on Sephadex G-200. The freeze-dried powder and solutions thereof were stable and were used for iodination to 1 atom 125 I/molecule antibody by the chloramine-T procedure. At high antigen concentrations 70-80% of the added [ 125 ]Ab was present in the sandwich. Linear response curves in the range 1-100 μg antigen/l incubate were obtained when [ 125 I]Ab was in slight excess. In this region an Ag : Ab ratio 1.9 : 1 was obtained which is consistent with the saturation of a bifunctional antibody. Although non-specific binding (in the absence of antigen) was consistently 125 I]Ab, this was the main factor in determining assay detection limits. The serum AFP levels from both non-pregnant and pregnant subjects as measured by the IRMA using the [ 125 I]monoclonal Ab and by radioimmunoassay (RIA) using a sheep antiserum to AFP were in excellent agreement. The IRMA was manipulatively simple, employed a shorter incubation time (2h), required shorter counting times than the RIA and gave a much wider working range. The provision of a monoclonal antibody for labelling removes the one major practicability barrier which otherwise limits the development and use of the potentially superior IRMA system. (Auth.)

  6. Development of simple immunoradiometric assays using avidin coupled to polystyrene beads as a common solid phase

    International Nuclear Information System (INIS)

    Jyotsna, N.; Singh, Y.; Chouthkanthiwar, V.; Paradkar, S.; Sivaprasad, N.

    1998-01-01

    In this paper, we describe the preparation and application of avidin coupled polystyrene beads as a common solid phase for use in immunoradiometric assays (IRMAs). The assay system is based on two matched commercial monoclonal antibodies, of which, the capture antibody is biotinylated using biotinamidocaproate N-hydroxysuccinimide ester and the detection antibody is radiolabeled with 125 I by conventional Chloramine-T method. Avidin was immobilized on the polystyrene beads through a primary coat of bovine serum albumin using glutaraldhyde activation method. Various factors, such as concentration of reagents, incubation time, etc. were optimised to obtain a simple assay protocol consisting of only two pipetting steps, namely, that of a mixture of the two labelled antibodies (radiolabelled and biotinylated) and of the standard or sample. The advantage of the Avidin-Biotin system is the improved sensitivity, economy of antibody and the possibility to use a common solid phase in assays for different analytes. Using the polystyrene beads along with the novel decanting device, it has been possible to achieve the convenience of the 'coated-tube' technology without the expensive automation necessary for large scale preparation of antibody coated tubes. This protocol has been successfully applied to Prolactin, LH and FSH assays. The sensitivity of the Prolactin assay is 8μIU/mL (0.3 ng/mL), that of the FSH assay is 1mIU/mL and that of the LH assay is 0.9 mIU/mL. The intra-assay and inter-assay variations were <10%. Shelf life of the avidin coupled beads was found to be about 8 months and that of the biotin labelled antibodies up to 18 months. (author)

  7. Tear and serum IgE concentrations by Tandem-R IgE immunoradiometric assay in allergic patients

    International Nuclear Information System (INIS)

    Insler, M.S.; Lim, J.M.; Queng, J.T.; Wanissorn, C.; McGovern, J.P.

    1987-01-01

    The authors studied a population of 39 allergic and 15 nonallergic patients, and determined their tear and serum IgE concentrations. Samples of tear and serum were tested for IgE by the Tandem-R immunoradiometric assay, which uses monoclonal antibody to produce a specific assay for IgE. The serum IgE levels in the study group showed a range from 23,280 to 16 IU/ml compared with controls of 72 to 2 IU/ml. Tear IgE in the study group varied from 159 IU/ml to less than 1 IU/ml compared with controls of 8 IU/ml to less than 1 IU/ml. A statistically significant correlation between tear and serum IgE exists in the allergic patients with eye symptoms. It also exists when serum IgE was greater than 100 IU/ml, the tear IgE greater than 4 IU/ml, or when both the serum IgE was greater than 100 IU/ml and the tear IgE greater than 4 IU/ml

  8. An immunoradiometric assay for procoagulant factor VIII antigen: results in haemophilia, von Willebrand's disease and fetal plasma and serum

    International Nuclear Information System (INIS)

    Peake, I.R.; Bloom, A.L.; Giddings, J.C.; Ludlam, C.A.

    1979-01-01

    An immunoradiometric assay (IRMA) has been developed based on the inhibitor which arose in a polytransfused severe haemophiliac. The two-site IRMA measured antigens closely associated with the procoagulant parts of the factor VIII complex, which are termed FVIIIC antigens or FVIIICAG. FVIIICAG was present in normal plasma and also, at a slightly lower concentration, in normal serum. In 37 patients with haemophilia A, 36 had FVIIICAG levels of less than 10% of the normal plasma pool. In patients with von Willebrand's disease the levels of FVIIIC and FVIIICAG were in good agreement, both before and after treatment with cryoprecipitate or DDAVP. FVIIICAG was relatively stable in plasma at 37 0 C and could also be detected in cord and fetal serum. The assay is of potential value for detecting reduced levels of factor VIII, for carrier detection and for the prenatal diagnosis of haemophilia. (author)

  9. Monoclonal antibodies for use in an immunoradiometric assay for. cap alpha. -foetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, W.M.; Bennie, J.G. (Medical Research Council, Edinburgh (UK). Immunoassay Team); Brock, D.J.H.; Heyningen, V. van (Western General Hospital, Edinburgh (UK))

    1982-04-29

    The advantages offered by a mouse IgG/sub 1/ monoclonal antibody to human ..cap alpha..-foetoprotein (AFP) for the preparation of (/sup 125/I)antibody for use in an immunoradiometric assay (IRMA) have been investigated. The antibody was isolated from ascites fluid by sodium sulphate precipitation followed by gel filtration on Sephadex G-200. The freeze-dried powder and solutions thereof were stable and were used for iodination to 1 atom /sup 125/I/molecule antibody by the chloramine-T procedure. At high antigen concentrations 70-80% of the added (/sup 125/)Ab was present in the sandwich. Linear response curves in the range 1-100 ..mu..g antigen/l incubate were obtained when (/sup 125/I)Ab was in slight excess. In this region an Ag : Ab ratio 1.9 : 1 was obtained which is consistent with the saturation of a bifunctional antibody. Although non-specific binding (in the absence of antigen) was consistently <0.1% of added (/sup 125/I)Ab, this was the main factor in determining assay detection limits. The serum AFP levels from both non-pregnant and pregnant subjects as measured by the IRMA using the (/sup 125/I)monoclonal Ab and by radioimmunoassay (RIA) using a sheep antiserum to AFP were in excellent agreement. The IRMA was manipulatively simple, employed a shorter incubation time (2h), required shorter counting times than the RIA and gave a much wider working range. The provision of a monoclonal antibody for labelling removes the one major practicability barrier which otherwise limits the development and use of the potentially superior IRMA system.

  10. Analytical and clinical performances of immunoradiometric assay of total and free PSA developed locally

    International Nuclear Information System (INIS)

    Boucekkine, N.; Korso, R.; Bellazoug, K.; Ferd, N.; Bouyoucef, S.E.; Boudjemai, S.; Benzaid, A.; Bouhila, Z.

    2002-01-01

    A specific assay was developed for total and free PSA (PSAt, PSAf). Both assay use a two site IRMA with polyclonal anti PSA antibodies coated on tubes. Polyclonal antibodies were obtained after rabbit's immunisation using an under skin injection of pure PSA in multiple site. For quantification, two monoclonal antibodies were selected, the first highly specific to free PSA and the second recognising both free and bound PSA. A correlation study was performed comparatively with two commercial kits from CIS Bio and Immunotech. For that purpose, 464 serums samples ranging from 0.5 ng/ml to 3399 ng/ml were used to characterise the analytical performance of the new test. The analytical detection limit of the new test was equal to 0.05 ng/ml for the total PSA and 0.02ng/ml for the free PSA. The within run and between-day coefficients of variation were to 20 ng/ml. For BPH, no significant difference was found between the three test for the ratio PSAf/PSAt using a cut off of 14% (all were>to 14%). For the 120 patients with PC, all PSAt were > to 2 ng/ml. However the mean value of PSAt was higher for the commercial kits (14.74 ng/ml against 12.48ng/ml for the new test) but all ratio of PSAf/PSAt for the 120 newly diagnosed cancer were <14%. In conclusion, our immunoradiometric assay developed locally has a good analytical performance and its outputs are well correlated to clinical findings in prostate disease. Furthermore, a cut off of 14% for the ratio PSAf/PSAt appears to be the most accurate tools to depict a prostate cancer

  11. Clinical evaluation of thyrotropin-releasing hormone (TRH) test with a sensitive immunoradiometric thyrotropin (TSH) assay kit

    International Nuclear Information System (INIS)

    Nakamura, Saeko; Demura, Reiko; Yamanaka, Yukako; Ishiwatari, Naoko; Jibiki, Kazuko; Odagiri, Emi; Demura, Hiroshi

    1987-01-01

    Thyrotropin-releasing hormone (TRH) test was performed using a commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) in patients with endocrine diseases. The basal serum concentration of TSH ranged from 0.2 to 2.9 μU/ml in healthy subjects. The values for endocrine diseases, except for Graves' disease, were almost within the normal range. A significant increase in TSH values caused by TRH test was observed in females compared with males (4.4 - 24.7 μU/ml vs 4.1 - 12.3 μU/ml). In cases of Graves' disease, there was a good correlation between the basal TSH value and the response of TSH to TRH. However, in the other endocrine diseases, including acromegaly, prolactinoma, anorexia nervosa, Cushing syndrome, and hypopituitarism, the response of TSH to TRH did not necessarily correlated with the basal TSH value. TRH test would be of value in elucidating pathophysiologic features, as well as in accurately diagnosing secretion reserve of TSH. (Namekawa, K.)

  12. Clinical evaluation of thyrotropin-releasing hormone (TRH) test with a sensitive immunoradiometric thyrotropin (TSH) assay kit

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Saeko; Demura, Reiko; Yamanaka, Yukako; Ishiwatari, Naoko; Jibiki, Kazuko; Odagiri, Emi; Demura, Hiroshi

    1987-10-01

    Thyrotropin-releasing hormone (TRH) test was performed using a commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) in patients with endocrine diseases. The basal serum concentration of TSH ranged from 0.2 to 2.9 ..mu..U/ml in healthy subjects. The values for endocrine diseases, except for Graves' disease, were almost within the normal range. A significant increase in TSH values caused by TRH test was observed in females compared with males (4.4 - 24.7 ..mu..U/ml vs 4.1 - 12.3 ..mu..U/ml). In cases of Graves' disease, there was a good correlation between the basal TSH value and the response of TSH to TRH. However, in the other endocrine diseases, including acromegaly, prolactinoma, anorexia nervosa, Cushing syndrome, and hypopituitarism, the response of TSH to TRH did not necessarily correlated with the basal TSH value. TRH test would be of value in elucidating pathophysiologic features, as well as in accurately diagnosing secretion reserve of TSH. (Namekawa, K.).

  13. Measurement of anti-IgA antibodies by a two-site immunoradiometric assay

    International Nuclear Information System (INIS)

    Homburger, H.A.; Smith, J.R.; Jacob, G.L.; Laschinger, C.; Naylor, D.H.; Pineda, A.A.

    1981-01-01

    To enable the detection of IgG class, anti-IgA antibodies and to investigate the possible occurrence of IgE class, anti-IgA antibodies, we developed a solid phase immunoradiometric assay, which uses purified IgA coupled covalently to microcrystalline cellulose as an immunosorbent. Radiolabeled, Fc specific anti-IgG and anti-IgE antibodies were used to detect specific aIgA after incubation of test sera or controls with the immunosorbent. IgG-aIgA were detected by the IRA in 100 and 67% of control sera with class specific and limited specificity aIgA. The IRA was sensitive to approximately two ng of class specific IgG-aIgA. IgG-aIgA also were detected by IRA in 7.9% of sera from patients with urticarial transfusion reactions and 73% of sera from patients with ataxia telangiectasia and IgA deficiency. Sera from 50 normal blood donors did not have detectable IgG-aIgA. Tests for IgE-aIgA were negative in all cases, including control sera with class specific IgG-aIgA. We conclude that the IRA is a sensitive and reproducible method for detection of class specific and limited specificity IgG-aIgA, and that IgE-aIgA do not mediate urticarial transfusion reactions

  14. Studies on the 2-site immunoradiometric assay of serum ferritin and its applications for diagnosis of iron deficiency

    Energy Technology Data Exchange (ETDEWEB)

    Koseki, J.; Niitsu, Y. (Sapporo Medical Coll. (Japan). Cancer Research Inst.)

    1980-10-01

    The 2-site immunoradiometric assay using paper discs as a solid phase material was established for the measurement of serum ferritin. The standard curve was found the range from 0.5ng -- 500ng ferritin per ml and the sensitivity limit of the assay was 0.1ng ferritin per ml. The clinical value of serum ferritin assay was then investigated for diagnosis of iron deficiency. The mean serum ferritin concentrations of normal subjects were greater for males (119.8+-55.5ng/ml) than for females (56.5+-55.5ng/ml) although this sex difference was not distinct beyond the age of 45. All 15 patients with iron deficient anemia had serum ferritin concentrations below the normal range, whereas in other anemias including anemia associated with chronic inflammation, pernicious anemia, aplastic anemia, serum ferritin concentrations were normal or elevated. In 116 apparently normal subjects, 13.8% of total females had abnormally low serum ferritin concentrations with normal hemoglobin levels. The cytochrome c oxidase activity of peripheral leucocytes from those subjects were generally depleted. Most of them frequently suffered from easy fatigability, weakness, and dizziness and these complications were clearly relieved by the administration of iron. Measurement of serum ferritin was found to be quite useful for diagnosis and assessment of iron deficient states.

  15. Highly Specific Detection of Myostatin Prodomain by an Immunoradiometric Sandwich Assay in Serum of Healthy Individuals and Patients

    Science.gov (United States)

    Widera, Christian; Gottlieb, Jens; Vogel, Arndt; Schmidt, Sebastian; Brandes, Gudrun; Heuft, Hans-Gert; Lichtinghagen, Ralf; Kempf, Tibor; Wollert, Kai C.; Bauersachs, Johann; Heineke, Joerg

    2013-01-01

    Background Myostatin is a muscle derived factor that functions as a negative regulator of skeletal muscle growth. Induction of myostatin expression was observed in rodent models of muscle wasting and in cachectic patients with cancer or pulmonary disease. Therefore, there is an increasing interest to use serum myostatin as a biomarker. Methods We established an immunoradiometric sandwich assay (IRMA), which uses a commercially available chicken polyclonal, affinity purified antibody directed against human myostatin prodomain. We determined the serum concentrations of myostatin prodomain in 249 healthy individuals as well as 169 patients with heart failure, 53 patients with cancer and 44 patients with chronic pulmonary disease. Results The IRMA had a detection limit of 0.7ng/ml, an intraassay imprecision of ≤14.1% and an interassay imprecision of ≤ 18.9%. The specificity of our assay was demonstrated by size exclusion chromatography, detection of myostatin by Western-blotting and a SMAD-dependent transcriptional-reporter assay in the signal-rich serum fractions, as well as lack of interference by unspecific substances like albumin, hemoglobin or lipids. Myostatin prodomain was stable at room temperature and resistant to freeze-thaw cycles. Apparently healthy individuals over the age of 55 had a median myostatin prodomain serum concentration of 3.9ng/ml (25th-75th percentiles, 2-7ng/ml) and we could not detect increased levels in patients with stable chronic heart failure or cancer related weight loss. In contrast, we found strongly elevated concentrations of myostatin prodomain (median 26.9ng/ml, 25th-75th percentiles, 7-100ng/ml) in the serum of underweight patients with chronic pulmonary disease. Conclusions We established a highly specific IRMA for the quantification of myostatin prodomain concentration in human serum. Our assay could be useful to study myostatin as a biomarker for example in patients with chronic pulmonary disease, as we detected highly

  16. Differences in serum thyroglobulin measurements by 3 commercial immunoradiometric assay kits and laboratory standardization using Certified Reference Material 457 (CRM-457).

    Science.gov (United States)

    Lee, Ji In; Kim, Ji Young; Choi, Joon Young; Kim, Hee Kyung; Jang, Hye Won; Hur, Kyu Yeon; Kim, Jae Hyeon; Kim, Kwang-Won; Chung, Jae Hoon; Kim, Sun Wook

    2010-09-01

    Serum thyroglobulin (Tg) is essential in the follow-up of patients with differentiated thyroid carcinoma (DTC). However, interchangeability and standardization between Tg assays have not yet been achieved, even with the development of an international Tg standard (Certified Reference Material 457 [CRM-457]). Serum Tg from 30 DTC patients and serially diluted CRM-457 were measured using 3 different immunoradiometric assays (IRMA-1, IRMA-2, IRMA-3). The intraclass correlation coefficient (ICC) method was used to describe the concordance of each IRMA to CRM-457. The serum Tg measured by 3 different IRMAs correlated well (r > .85, p CRM-457, showed the best ICC (p(1) = .98) for the CRM-457. Hospitals caring for patients with DTC should either set their own cutoffs for IRMAs for Tg based on their patient pools, or adopt IRMAs standardized to CRM-457 and calibrate their laboratory using CRM-457.

  17. Basic Evaluation of Analytical Performance and Clinical Utility of Immunoradiometric TSH Assay

    International Nuclear Information System (INIS)

    Suhy, Il Kyo; Cho, Bo Youn; Lee, Hong Kyu; Koh, Chang Soon; Min, Hun Ki; Lee, Mun Ho

    1987-01-01

    To assess the analytic performance of immunoradiometric TSH assay (IRMA TSH), assay precision determined by intra and interassay variance, assay accuracy determined by dilution and recovery study, were evaluated by using two commercial kit (Abott and Daichi). Normal range of basal serum TSH and TRH stimulated TSH increment were also determined in 234 healthy subjects (male 110, female 124; age 20-70) and 30 volunteers (male 10, female 20; age 21-26). In addition, basal TSH levels of 70 patients with untreated hyperthyroidism, 50 untreated hypothyroidism, and 60 euthyroidism were measured to assess the clinical utility of IRMA TSH. The detection limit of IRMA TSH was 0.04 mU/l and 0.08 mU/l by Abott Kit and Daichi kit respectively. Using Abott kit, intraassay variance were 2.0, 3.1 and 1.4% in mean TSH concentration 2.4, 31.6 and 98.2 mU/l repectively and interassay variance were 2.0 and 3.2% in mean TSH concentration 2.3 and 31.3 mU/l. Mean recovery rate was 92.5% and dilution study showed nearly straight line. When Daichi kit was used, intrasssay variance were 5.6, 5.2 and 6.2% in mean TSH concentration of 2.4, 31.6 and 98.2 mU/1 respectively and interassay variance were 7.1 and 7.4% in mean TSH of 2.3 and 31.3 mU,/l. Mean recovery rate was 89.9%. Normal range of basal TSH and TRH stimulated peak TSH were 0.38-4.02 mU/1 and 2.85-30.8 mU/1 repectively (95% confidence interval, Abott kit used). Sensitivity and specificity of basal TSH levels for diagnosing hypothyroidism as well as specificity for diagnosing hyperthyroidism were 100% by using both kit. Sensitivity of basal TSH level for diagnosing hyperthyroidism was 100% when TSH levels were measured by Abott kit while that was 80.9% when measured by Daichi kit. These results suggest that IRMA TSH was very precise and accurate method and might be used as a first line test in the evaluation of thyroid function

  18. A three-layer immunoradiometric assay for determination of IgG subclass antibodies in Human Sera (''IgG subclass RAST'')

    International Nuclear Information System (INIS)

    Djurup, R.; Soendergaard, I.; Weeke, B.; University of Copenhagen, Denmark); Magnusson, C.G.M.

    1984-01-01

    We report the development of a three-layer immunoradiometric assay (TIRA) for measurement of IgG antibodies of all four subclasses in human sera. The first layer consists of diluted human serum, the second layer is monoclonal mouse antibodies to human IgG subclasses, and the third layer is 125 I-labelled rabbit anti-mouse IgG. Monoclonal anti-IgGI, anti-IgG3 and anti-IgG4 reacted only with their complementary IgG subclass, whereas the anti-IgG2 showed slight cross-reactivity to immunoglobins of other subclasses and classes and to light chain proteins. The observed cross-reactivity was found to be without importance, when the TIRA was applied to measurement of IgG subclass antibodies. Equipotency was established by use of appropriate dilutions of the monoclonal antibodies, and the assay was calibrated by use of human reference serum. The TIRA therefore permits reliable inter-individual and intra-individual comparisons of the IgG antibody response in all four subclasses. Non-specific binding obtained with pooled normal human serum was below 0.33%. Inter-assay coefficient of variation was between 18 and 27%. The TIRA was applied to measurement of IgG subclass antibodies to timothy grass pollen in sera from grass pollen allergies undergoing immunotherapy. (author)

  19. Studies on the 2-site immunoradiometric assay of serum ferritin and its applications for diagnosis of iron deficiency

    International Nuclear Information System (INIS)

    Koseki, Junichi; Niitsu, Yoshiro

    1980-01-01

    The 2-site immunoradiometric assay using paper discs as a solid phase material was established for the measurement of serum ferritin. The standard curve was found the range from 0.5ng -- 500ng ferritin per ml and the sensitivity limit of the assay was 0.1ng ferritin per ml. The clinical value of serum ferritin assay was then investigated for diagnosis of iron deficiency. The mean serum ferritin concentrations of normal subjects were greater for males (119.8+-55.5ng/ml) than for females (56.5+-55.5ng/ml) although this sex difference was not distinct beyond the age of 45. All 15 patients with iron deficient anemia had serum ferritin concentrations below the normal range, whereas in other anemias including anemia associated with chronic inflammation, pernicious anemia, aplastic anemia, serum ferritin concentrations were normal oe elevated. In 116 apparently normal subjects, 13.8% of total females had abnormally low serum ferritin concentrations with normal hemoglobin levels. The cytochrome c oxidase activity of peripheral leucocytes from those subjects were generally depleted. Most of them frequently suffered from easy fatiguability, weakness, and dizziness and these complications were clearly relieved by the administration of iron. Measurement of serum ferritin was found to be quite useful for diagnosis and assessment of iron deficient states. (author)

  20. Clinical experience of a sensitive immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH)

    International Nuclear Information System (INIS)

    Nakamura, Saeko; Jibiki, Kazuko; Demura, Reiko; Koike, Sachiko; Kurihara, Shigeko; Odagiri, Emi; Demura, Hiroshi

    1987-01-01

    A commercially available immunoradiometric thyrotropin (TSH) assay kit (RIA-gnost hTSH) was used to study the concentration of TSH in serum in a series of 124 patients with thyroid dysfunction and 35 normal controls. Laboratory test for RIA-gnost hTSH showed a detection limit for TSH to be 0.03 μU/ml. The basal serum concentration of TSH in normal controls ranged from 0.17 to 3.21 μU/ml, with a mean of 0.74 μU/ml. It was less than 0.04 μU/ml in all 28 untreated patients with Graves' disease, indicating the discrimination between normal and hyperthyroid subjects. In the case of untreated 7 patients with hypothalamic hypopituitarism, the basal TSH concentration ranged from 0.80 to 13.5 μU/ml. There was no consistent tendency for changes in TSH levels with normalization of free thyroxine in 8 treated patients with Graves' disease. The basal serum concentration of TSH reflected the response of TSH to thyrotropin releasing hormone in 10 treated patients with Graves' disease. The use of the RIA-gnost hTSH would be of clinical significance in the diagnosis and management of patients with Graves' disease or hypopituitarism. (Namekawa, K.)

  1. Determination of congenital hypothyroidism in neonatal by immunoradiometric assays of thyrotropin

    International Nuclear Information System (INIS)

    Contreras P, E.

    1998-01-01

    The congenital hypothyroidism is the endocrine illness more frequent of the childhood, it is the one that produce the devastating effects on the growth and the development. It represent one of the few causes of mental delay that it could be prevented if it is diagnosed and treaty on time. The infants affected with congenital hypothyroidism, could be detected for the apparent presence of some physical abnormalities, which comes the first days of the birth. Unfortunately, in the moment in which the classical manifestations are made present, it is very probable that cerebral damage already exists, for what the affected children should be tried before the three months of life administering them thyroid hormones. In Mexico the incidence of the congenital hypothyroidism is of one for each 1612 births for that is very important in the area of Public Health diagnose in early form and with certainty the congenital hypothyroidism. The TSH hormone or thyrotropin is formed in the hypophysis and intervenes in the synthesis of the thyroid hormones (T3, T4) when the concentration of these is adapted, the formation of TSH is inhibited, for that upon lacking the thyroid hormones the concentration of TSH in the blood is high. For these reasons the shot metabolic state of a newborn could be determined, quantifying the TSH in blood obtained by heel stab of the neonatal, or in coming blood from the umbilical cord, after 48 hours of being born. However because the TSH is similar to other hormones and is in extremely low concentrations, it is made necessary appeal analytic techniques of very sensitive and specific laboratory like the Immunoradiometric assays (Irma) in order to could determine the levels of this hormone in the blood. (Author)

  2. Human chorionic gonadotropin (HCG) and alphafeto protein (AFP) in sudanese pregnant women using immunoradiometric assay

    International Nuclear Information System (INIS)

    Abdalla, O. M.; Khalid, M. M.; Hassan, A.; Ali, N. I.; Khalid, A. SH.; Abdelhadi, H. A.; Khair, L. A. M.; Almahi, W. A.; Gaafar, A.; Abdalla, H.; Basheer, H.

    2004-12-01

    In this study 672 pregnant Sudanese women were involved in order to determine the reference values of human chorionic gonadotropin (HCG) and alpha feto protein (AFP). Blood samples were collected from different maternity centers in Khartoum and Omdurman maternity. Sensitive immunoradiometric assay (IRMA), method was used for measuring HCG and AFP in maternal serum. The data collected reveals that, the behavior of both AFP and HCG resemble that of the international one, where the peak concentrations of HCG are reached at 7-9 weeks of pregnancy then decrease, then staying relatively constant during the second trimester and increasing slightly towards term. The maternal serum concentration of AFP increases during pregnancy, reaching its peak during the last trimester. The concentration of AFP and HCG in maternal serum with relative couples was also compared to that of ir relative couples. Relative couples showed significant increase in maternal AFP level in the first and third trimesters (p=0.001and 0.000) respectively. The HCG concentration in both groups was not significantly different throughout the pregnancy (p>0.15). It is recommended that each laboratory establishes its own normal values. Since sudanese obstetrician depends previously on values from abroad, this study may help them to handle their patients depending on our own reference values.(Author)

  3. Human chorionic gonadotropin (HCG) and alphafeto protein (AFP) in Sudanese pregnant women using immunoradiometric assay

    International Nuclear Information System (INIS)

    Abdalla, O. M.; Khalid, M. M.; Hassan, A.; Ali, N. I.; Khalid, A. SH.; Abdelhadi, H. A.; Khair, L. A. M.; Almahi, W. A.; Gaafar, A.; Abdalla, H.; Basheer, H.

    2004-01-01

    In this study 672 pregnant Sudanese women were involved in order to determine the reference values of Human Chorionic Gonadotropin (HCG) and alpha feto protein (AFP). Blood samples were collected from different maternity centers in Khartoum and Omdurman maternity. Sensitive immunoradiometric assay (IRMA), method was used for measuring HCG and AFP in maternal serum. The data collected reveals that, the behavior of both AFP and HCG resemble that of the international one, where the peak concentrations of HCG are reached at 7-9 weeks of pregnancy then decrease, then staying relatively constant during the second trimester and increasing slightly towards term. The maternal serum concentration of AFP increases during pregnancy, reaching its peak during the last trimester. The concentration of AFP and HCG in maternal serum with relative couples was also compared to that of ir relative couples. Relative couples showed significant increase in maternal AFP level in the first and third trimesters (p= 0.001and 0.000) respectively. The HCG concentration in both groups was not significantly different throughout the pregnancy (p> 0.15). It is recommended that each laboratory establishes its own normal values. Since Sudanese obstetrician depends previously on values from abroad, this study may help them to handle their patients depending on our own reference values. (Authors)

  4. Antibodies immobilized on magnetic particles for radioimmunoassay and immunoradiometric assay of hormones. Final report of a co-ordinated research programme 1991-1995

    International Nuclear Information System (INIS)

    1996-11-01

    The IAEA organized a co-ordinated research programme (CRP) in 1991 for studying the properties of a few most promising magnetizable immunoadsorbents and standardizing some important radioimmunoassay and immunoradiometric assay procedures using them with the ultimate aim of expanding the application of these assays in developing countries using indigenously prepared reagents. Ten laboratories from nine countries of Asia, Latin America and Europe participated in this CRP which was concluded in 1995. Three different magnetizable particles prepared and investigated by the participants, namely magnetite, magnetite coated with silane and magnetite coated with polyacrolein, have emerged suitable for use in radioimmunometric assays from this CRP. Methods have been developed for coupling antibodies to these particles and using the resultant immunoadsorbents for assaying several important hormones and proteins including T 3 , T 4 , fT 3 , fT 4 , reverse T 3 , TSH, thyroglobuling(Tg), Tg-antibodies, HCG, LH, cortisol, FSH and prolacting. All the participating laboratories could develop in house methodology for solid phase assays based on magnetizable particles during the course of the CRP and benefit from the exchange of materials, information and experience amongst them. This report includes detailed results obtained by the participating laboratories as well as a summary and assessment of the achievements of the CRP. It also includes suggestions for areas of investigation for pursuing in the future. Refs, figs, tabs

  5. The value of the indirect immunoradiometric assay of serum alpha - fetoprotein in detecting liver regeneration and neoplastic transformation in chronic liver disease. Part of a coordinated programme on in vitro assay techniques

    International Nuclear Information System (INIS)

    Voiculetz, N.

    1979-07-01

    To investigate the concentration of alphafetoprotein AFP in different liver diseases and above all in liver cancer the immunoradiometric assay was utilized. The results of AFP studies were compared with regeneration index, blastic T lymphocytes transformation as well as other morphological and biochemical data. The results of the investigations indicated that: 38% of chronic benign hepatopathies displayed the values of serum AFP in normal ranges, 54% were in the range of 41 - 200ng/ml, and 8% showed 200 and more ng/ml. The most important conclusion from the work performed was that the elevation of serum AFP level in the evaluation of chronic hepatopathies, especially in cirrhoses, appears as an index of malignancy

  6. Immunoassay of blood spot TSH; development of a rapid two-site immunoradiometric assay and comparison with radioimmunoassay as a screening method for neonatal hypothyroidism

    International Nuclear Information System (INIS)

    Sutherland, R.M.; Ratcliffe, J.G.; Chapman, R.S.

    1982-01-01

    The development of a two-site immunoradiometric assay (IRMA) for thyrotropin (TSH) eluted from dried blood filter paper discs is described and compared with a conventional TSH radioimmunoassay (RIA) as a screening procedure for neonatal hypothyroidism. The two-site IRMA involves a primary incubation of excess labelled TSH antibody and the blood disc for 16-18 h at pH 8 and a secondary 3 h incubation under agitation, with solid phase TSH antibody. Bound and free fractions are separated by a semi-automated washing procedure. It is concluded that the two-site TSH IRMA has advantages over conventional RIA in speed, sensitivity, precision and ruggedness and can be recommended as an efficient screening procedure for neonatal hypothyroidism. (Auth.)

  7. A modified direct insulin lodination for insulin radioreceptor assay in human erythrocytes

    Energy Technology Data Exchange (ETDEWEB)

    Elnabrawie, F S; Megahed, Y M; Fahim, F A; Ahmed, A M [Middle Eastern Regional radioisotope center for Arab Countries biochemistry dept. Faculty of science Ain Shams university, cairo, (Egypt)

    1995-10-01

    A substitution of iodine in to the inulin molecule will easily lead to a decreased hormonal activity. Nevertheless it cannot be concluded without further investigation that one or several of the tyrosyl groups are directly involve in the degree of iodination and the loss activity has been demonstrated by many workers, (Frenkel-Conrat 1950, and de Zoeten and van Strik, 1961). On the basis of the Frenkel-Conrat experiments, lee 1957 suggested that a mono-substitution of iodine in two tyrosyl groups is possible without loss of biological activity. In general, iodination is easy to perform as usually carried out at room temperature at PH of 7.5 in a phosphate buffer medium (Megahed et al., 1976, 1979). Reaction between antigen and antibody in radioimmunoassay (RIA), immunoradiometric assay (IRMA) and radioreceptor assay (RRA), is detected by radiation emitted from a radioisotope incorporated into the antigen or antibody molecule. Ideally the radiolabelled molecule has an immunoreactivity identical to the natural molecule and this behaves in the same way as in the assay procedure. Oxidation of 125 I-iodide gives rise to the 125 I-iodination which in a mildly alkaline PH (7.5) reacts with the phenolic benzene ring of tyrosine and tyrosyl residues by a process of electrophilic attack.

  8. A modified direct insulin lodination for insulin radioreceptor assay in human erythrocytes

    International Nuclear Information System (INIS)

    Elnabrawie, F.S.; Megahed, Y.M.; Fahim, F.A.; Ahmed, A.M.

    1995-01-01

    A substitution of iodine in to the inulin molecule will easily lead to a decreased hormonal activity. Nevertheless it cannot be concluded without further investigation that one or several of the tyrosyl groups are directly involve in the degree of iodination and the loss activity has been demonstrated by many workers, (Frenkel-Conrat 1950, and de Zoeten and van Strik, 1961). On the basis of the Frenkel-Conrat experiments, lee 1957 suggested that a mono-substitution of iodine in two tyrosyl groups is possible without loss of biological activity. In general, iodination is easy to perform as usually carried out at room temperature at PH of 7.5 in a phosphate buffer medium (Megahed et al., 1976, 1979). Reaction between antigen and antibody in radioimmunoassay (RIA), immunoradiometric assay (IRMA) and radioreceptor assay (RRA), is detected by radiation emitted from a radioisotope incorporated into the antigen or antibody molecule. Ideally the radiolabelled molecule has an immunoreactivity identical to the natural molecule and this behaves in the same way as in the assay procedure. Oxidation of 125 I-iodide gives rise to the 125 I-iodination which in a mildly alkaline PH (7.5) reacts with the phenolic benzene ring of tyrosine and tyrosyl residues by a process of electrophilic attack

  9. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    International Nuclear Information System (INIS)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo

    2011-01-01

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R 2= 0.838, P 2= 0.067, P=0.316 by IRMA, and R 2= 0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients

  10. Immunoradiometric assay for the determination of E. coli proteins in recombinant dna derived human growth hormone produced at IPEN-CNEN/SP

    International Nuclear Information System (INIS)

    Soares, Carlos R.J.

    1995-01-01

    An immunoradiometric assay (IRMA) for the determination of multiple antigens was set up in order to quantify E. coli (ECP) in lots of purified recombinant human growth hormone (rec-hGH). SDS-PAGE and Western Blotting techniques were carried out, in parallel, to confirm the results obtained by IRMA and to provide more information about the contaminants. Anti-ECP antibodies were obtained by rabbit immunization with ECP, which were submitted to the same purification process utilized for rec-hGH with the exception of the last step. A strain-process-specific assay was thus set up. The antiserum obtained was purified through an affinity column prepared with the same ECP used for immunization, this provided an highly sensitive assay (0,03 ng ECP/mL). This IRMA was shown to be specific, not presenting any cross reaction with hGH and studies carried out on precision, accuracy and linearity of response with dilution confirmed its validity as one of the fundamental purity tests for rec-hGH produced at IPEN-CNEN/SP, whose principles can be easily extended to the analysis of other similar products. These studies have also shown that the utilization of an affinity column, prepared with the described anti-ECP antiserum was very effective, providing rec-hGH lots with less then 10 parts per million (0,001%) of contaminating proteins. (author). 45 refs., 15 figs., 11 tabs

  11. Immunoradiometric versus radioimmunoassay: a comparison using alpha-fetoprotein as the model analyte

    International Nuclear Information System (INIS)

    Hunter, W.M.; Budd, P.S.

    1981-01-01

    With alpha-fetoprotein as a model a formal comparison has been made between inhibition type radioimmunoassay with radioiodinated antigen, liquid-phase incubation and double antibody separation (RIA) and variants of the sandwich immunoradiometric assay (IRMA). 125 I-antibody was prepared (expensively) by labelling the IgG fraction and subsequently undertaking immunopurification to yield a reproducibly-high quality reagent, 70-75% being reactive with antigen. The same antiserum was coupled to Sepharose 4B for use in the IRMA and separation was by the sucrose layer procedure (Hunter, 1980) which obviates the need for centrifugation. The principal basis used for the comparison was computer-generated precision profiles (Ekins, 1976), each of which was derived from 10 assays of each kind. (Auth.)

  12. Ultrasensitive immunoradiometric assay for chorionic gonadotropin which does not cross-react with luteinizing hormone nor free β chain of hCG and which detects hCG in blood of non-pregnant humans

    International Nuclear Information System (INIS)

    Griffin, J.; Odell, W.D.

    1987-01-01

    A sensitive, non-competitive, two-monoclonal antibody, sandwich-type or immunoradiometric assay has been developed for human chorionic gonadotropin (hCG) which shows no cross-reaction with the free β chain of hCG nor with human luteinizing hormone (LH). In the assay procedure, two, highly selected monoclonal antibodies reacted in solution with hCG to be quantified. One antibody was covalently conjugated to biotin. This antibody was specific for the β subunit of hCG, and showed no reaction with LH nor the α subunit. The second antibody was labelled with 125 I and was specific for intact hCG and LH, showing no cross-reaction with βhCG nor the α subunit. The separation system was a polystyrene ball conjugated with biotin. This ball bound via an avidin bridge the monoclonal 'sandwich' containing hCG. Counts per minute bound to the ball were directly proportional to the amount of hCG present. The assay was specific for whole hCG and showed no reaction with βhCG, βLH, intact LH nor the free α subunit. Sensitivity was adequate to detect 'hCG-like' material in all post menopausal women and, when single samples were obtained, in over 2/3 of normal men. When multiple samples were obtained, 'hCG-like' material was detectable in all eugonadal adults studied. 27 refs.; 4 figs.; 1 table

  13. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National Univ. Seoul (Korea, Republic of)

    2011-03-15

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R{sup 2=}0.838, P<0.001). Serum HBsAg level and serum HBV DNA copies were found to be linearly related by both methods (R{sup 2=}0.067, P=0.316 by IRMA, and R{sup 2=}0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients.

  14. The trial detection of malaria sporozoit in field-collected mosquito by immunoradiometric assay in Thailand

    International Nuclear Information System (INIS)

    Kasemsuth, R.; Asavanich, A.; Sucharit, S.; Vutikes, S.; Vutikes, M.; Patamatum, S.

    1988-01-01

    The sporozoite rate, species of parasite and vector are important in the epidemiology of malaria. The investigation of sporozoite by dissection and examination under a microscope is time-consuming and it could be done only on freshly killed mosquitoes. Immunoradiometric assay (IRMA) that can detect, identify and quantify malaria sporozoite (Zavala et al., 1982) was therefore applied to detect sporozoite in laboratory-maintained Anopheles dirus and wild-caught mosquitoes. Study on P. falciparum-infected An. dirus showed that the circumsporozoite (CS) antigen was first found in the abdomen on the 10th day post-infection, whilst the sporozoites were examined in salivary glands from day 15 onwards. The malaria infection in wild-caught mosquitoes were investigated in Anopheles spp collected by human baites from three endemic areas in Thailand. Since the sporozoite rate refers to the presence of sporozoite in the salivary gland, then only head-thorax part of the specimens were detected by IRMA to prevent an exaggeration over the true results. It was found that none of mosquitoes collected from Phrae was positive for malaria. Four out of 1243 An. dirus among eight species collected from Chantaburi were positive for P. falciparum with sporozoites ranged from 270 to 3875. Of all ten species collected from Kanchanaburi, two and one out of 3123 An. minimus were positive for P. falciparum and P. vivax with sporozoites found in head-thorax portions were 1880, 2380 and 1026 respectively. It is evident that the IRMA is suitable for the investigation of malaria sporozoites in this region. The application of this technique in the further epidemiological study is in progress

  15. Fundamental and clinical study of direct immunoradiometric assay in human renin concentration

    International Nuclear Information System (INIS)

    Kurimoto, Fumihiko; Horiuchi, Junko; Sakurai, Hyoichiro; Suzuki, Hiromichi; Takita, Takashi; Saruta, Takao.

    1988-01-01

    'Renin RIA Pasteur' kit for directly measuring renin concentration in human plasma (PRC) was fundamentally and clinically evaluated. A standard curve for PRC was linear in the range of 10 - 640 pg/ml. Reproducibility, recovery, and stability were satisfactory. There was a significantly positive correlation between direct PRC and conventional plasma renin activity (PRA) and indirect PRC. PRC was directly measured in 119 healthy volunteers and 15 patients with primary aldosteronism (4), Cushing's syndrome (6), or non-functioning tumor (5). The basal PRC was 32.4 +- 18.8 pg/ml for men and 37.9 +- 22.6 pg/ml for women. PRC for primary aldosteronism was below detectable levels, and remained unchanged even after the administratin of ACTH. In the case of Cushing's syndrome, mean PRC and PRA were 19 pg/ml and 1.2 ng/ml/hr, and did not respond to ACTH. Although the administration of ATCH was significantly associated with a decreased PRC, there was only tendency toward the decreased PRA in the case of non-functioning tumors. The results indicate the usefulness of the present kit in terms of its ability to directly measure PRC without any complicated procedures. (Namekawa, K.)

  16. Fluid-phase immunoradiometric assay for the detection of qualitative abnormalities of factor VIII/von Willebrand factor in variants of von Willebrand's disease

    International Nuclear Information System (INIS)

    Girma, J.P.; Ardaillou, N.; Meyer, D.; Lavergne, J.M.; Larrieu, M.J.

    1979-01-01

    Antigenic reactivity of F.VIII/WF in variants of von Willebrand's disease (vWd) was studied with both fluid-phase and solid-phase immunoradiometric assays. Two different (rabbit and goat) 125 I-labeled specific antibodies against purified F.VIII/WF were used in both their divalent (lgG) and their monovalent (Fab fragment) forms. Dose-response curves obtained by reacting a constant amount of antibody with serial dilutions of plasmas from normal or homozygous vWd demonstrated the specificity of the test. The accuracy was significantly higher with 125 I-Fab fragments of goat anti-F.VIII/WF antiserum than intact goat lgG or rabbit lgG or Fab fragments. The significant decrease of the slope of the dose-response curves obtained with plasma from variants of vWd has been interpreted as due to the presence of abnormal F.VIII/WF molecules with decreased antigenic reactivity. A similar anomaly was found in cryosupernatant prepared from normal plasma, paralleling similarities demonstrated between variants of vWd and cryosupernatant. Results of experiments performed by reacting constant plasma dilutions from control or variants of vWd and varying concentrations of anti-F.VIII/WF Fab fragments (rabbit or goat) confirmed the decreased antigenic reactivity of variant F.VIII/WF

  17. Study on quantification of HBs-antibody by immunoradiometric assay

    International Nuclear Information System (INIS)

    Kondo, Yuichi; Itoi, Yoshihiro; Kajiyama, Shizuo

    1989-01-01

    Quantification of HBs-antibody assay was carried out using a commercialized assay kit and standard solutions of HBs-antibody recognised as 1 st reference preparation of hepatitis B immunogloblin by WHO. Standard curve of HBs-antibody was drawn with the function of 3D-spline and the correlation factor was obtained as r = 0.999. Coefficient of intra-assay variance was 3.8 % and that of inter-assay variance was 7.8 %. Dilution tests showed satisfactory results in the range of 2-16 times. Correlation between value of cut-off indices and concentration of HBs-antibody was obtained as the formula of y = 2.599 x-3.894 (r = 0.992) and 2.1 of cut-off index corresponded to about 5 mIU/ml of HBs-antibody concentration. (author)

  18. Comparative assessment of quality of immunoradiometric assay (IRMA) and chemiluminescence immunometric assay (CHEIMA) for estimation of thyroid stimulating hormone (TSH)

    International Nuclear Information System (INIS)

    Sajid, K.M.

    2009-01-01

    Biological substances like hormones, vitamins and enzymes are found in minute quantities in blood. Their estimation requires very sensitive and specific methods. The most modern method for estimation of thyroid stimulating hormone in serum is non-isotopic enzyme enhanced chemiluminescence immunometric method. In our laboratory immunoradiometric assay is in routine for the last many years. Recently interest has grown to establish non-isotopic techniques in laboratories of PAEC. However, the main requirement to adopt the new procedures is to compare their results, cost and other benefits with the existing method. Immunoassay laboratory of MINAR, therefore, conducted a study to compare the two methods. A total of 173 (males: 34 females: 139 age: between 1 and 65 years) cases of clinically confirmed thyroid status were included in the study. Serum samples of these cases were analyzed by two methods and results were compared by plotting precision profiles, correlation plots and calculating sensitivities and specificities of the methods. As the results in all the samples were not normally distributed Wilcoxon rank sum test was applied to compare the analytical results of two methods. The comparison shows that the results obtained in two methods are not completely similar (p=0.0003293), although analysis of samples in groups shows that some similarity exists between the results of hypo and hyperthyroid patients (p<=0.156 and p<=0.6138). This shows that results obtained in these two methods could sometimes disagree in final diagnosis. Although TSH-CHEIMA is analytically more sensitive than TSH-IRMA the clinical sensitivities and specificities of two methods are not significantly different. TSH-CHEIMA test completes in almost 2 hours whereas TSH-IRMA takes about 6 hours to complete. Comparison of costs shows that TSH-CHIEMA is almost 5 times more expensive than TSH-IRMA. We conclude that the two methods could sometimes disagree but the two techniques have almost same

  19. Initial diagnosis and follow-up in thyroid dysfunctions by use of immunoradiometric TSH measurement

    International Nuclear Information System (INIS)

    Joseph, K.

    1985-01-01

    4.245 patient studies with a highly sensitive immunoradiometric TSH assay revealed a normal range from 0.1 to 3.5 mU/l. Hyperthyroid patients had TSH values 6.0 mU/l. The results of TRH stimulation after nasal application of 2 mg TRH are strongly related to basal TSH measurement, thus, a demand on TRH tests exists only in basal TSH concentrations 0.1 to 0.3 mU/l and 3.5 to 6.0 mU/l for latent function anomalies. During T 4 therapy basal TSH values below 0.3 mU/l are indicative for sufficient suppression, for proof of overdosage T 3 parameters have to be used. In antithyroid drug therapy basal TSH measurement is important after the initial phase of therapy for precise antithyroid drug dosage. Therefore, the highly sensitive TSH measurement is the most important initial parameter for exclusion or evidence of thyroid function anomaly. (orig.) [de

  20. Comparison of pituitary and recombinant human thyrotropin standards in an immunoradiometric system

    International Nuclear Information System (INIS)

    Blanca Fernandez, Silvia; Rodriguez Gonzalez, Julio Cesar; Nisembaum Alas, Amaparo; Sevy Gonzalez, O.

    1998-01-01

    Results of two standards of human thyrotropin of pituitaries (B) and recombinant (C) origen supplied by the Instituto of pesquisas Energeticas y Nucleares, Brazil, were compared in our immunoradiometric reference system that use an human thyrotropin pituitary standard of local production (A). This work was supported by the International Atomic Energy Agency for an inter-regional comparison and set up of a reference standard

  1. Determination of congenital hypothyroidism in neonatal by immunoradiometric assays of thyrotropin; Determinacion de hipotiroidismo congenito en neonatos por analisis inmunoradiometrico de tirotrofina

    Energy Technology Data Exchange (ETDEWEB)

    Contreras P, E

    1998-06-01

    The congenital hypothyroidism is the endocrine illness more frequent of the childhood, it is the one that produce the devastating effects on the growth and the development. It represent one of the few causes of mental delay that it could be prevented if it is diagnosed and treaty on time. The infants affected with congenital hypothyroidism, could be detected for the apparent presence of some physical abnormalities, which comes the first days of the birth. Unfortunately, in the moment in which the classical manifestations are made present, it is very probable that cerebral damage already exists, for what the affected children should be tried before the three months of life administering them thyroid hormones. In Mexico the incidence of the congenital hypothyroidism is of one for each 1612 births for that is very important in the area of Public Health diagnose in early form and with certainty the congenital hypothyroidism. The TSH hormone or thyrotropin is formed in the hypophysis and intervenes in the synthesis of the thyroid hormones (T3, T4) when the concentration of these is adapted, the formation of TSH is inhibited, for that upon lacking the thyroid hormones the concentration of TSH in the blood is high. For these reasons the shot metabolic state of a newborn could be determined, quantifying the TSH in blood obtained by heel stab of the neonatal, or in coming blood from the umbilical cord, after 48 hours of being born. However because the TSH is similar to other hormones and is in extremely low concentrations, it is made necessary appeal analytic techniques of very sensitive and specific laboratory like the Immunoradiometric assays (Irma) in order to could determine the levels of this hormone in the blood. (Author).

  2. A simple assay for the detection of antibodies to endocrine islet cell surface antigens

    International Nuclear Information System (INIS)

    Contreas, G.; Madsen, O.D.; Vissing, H.; Lernmark, Aa.

    1986-01-01

    A simple and sensitive immunoradiometric assay for the detection of islet cell surface antibodies (CIRMA) has been developed. Live, transformed islet cells derived from a liver metastasis of a transplantable islet cell tumor were grown in removable microtiter wells and incubated with antibody. Cell-bound antibodies were quantitated using 125 I-labelled second antibodies. The assay was used to detect islet cell antibodies present in sera from non-diabetic and diabetic BB rats and proved to be particularly effective for screening hybridoma supernatants in order to identify monoclonal antibodies recognizing islet cell surface antigens. (Auth.)

  3. Immunoassays in clinical chemistry (principles of immunoradiometric assays)

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    The use of antibodies as reagents in clinical chemistry for the quantitation of a wide range of analytes has now become widely established. Initially antibodies were employed in precipitation techniques, usually for the analysis of serum proteins, in solution or in the form of antibody containing gels, e.g. immunoprecipitation, immunodiffusion, and immunoelectrophoresis. Further developments have led to the highly sensitive techniques of radioimmunoassay and recently immunometric assay for the measurement of drugs, tumour markers and hormones. In general, those techniques without the addition of a label e.g. immunoprecipitation, immunodiffusion and immunoturbidimetry are the older techniques used for the measurement of serum proteins. These techniques are relatively insensitive, measuring at the g/L. level, and in the case of immunodiffusion are generally slow. Automation coupled with the development of chemistries to enhance precipitation has, however, reduced measurement times to minutes in modern laboratories. Nevertheless these methods have detection limits of the order of 1 g/L

  4. Serum gonadotropins levels in childhood

    International Nuclear Information System (INIS)

    Hertogh, R. De; Vankrieken, L.; Wolter, R.; Vliet, G. Van

    1989-01-01

    The complex changes in serum LH and FSH levels from infancy to adulthood are diversely evaluated by radioimmunoassays or bioassays. The relative lack of sensitivity and specificity of radioimmunoassay, using polyclonal antibodies, could possibly be overcome by new immunoradiometric assays, using specific antibodies to LH and FSH. Significant differences were indeed observed between radioimmunoassays and immunoradiometric assays. During the prepubertal period, LH levels, measured by the immunoradiometric assays, were below the sensitivity of the method in the majority of the samples. LH levels were, however, well detectable when measured with radioimmunoassay, showing the heterogeneity of circulating LH structures. At the onset of puberty, LH levels increased at least 3 to 4 times in both sexes, when measured with immunoradiometric assays, whereas their increase was only 20 to 60% with the radioimmunoassays. FSH levels remained well detectable in the prepubertal period whether measured by immunoradiometric or radioimmunoassays. At pubertal onset, FSH increase in both sexes was more important in the immunoradiometric assays. The results obtained with immunoradiometric assays give a better insight into the quantitative and qualitative function of the gonadotropes during childhood. The almost complete absence of LH during the prepubertal period and the steep increase at the onset of puberty better reflects the reported data obtained with bioassays. The persistance of significant levels of FSH in the prepubertal ages, and the lesser increase at the onset of puberty, when compared with LH, illustrates that the individual regulation of LH and FSH secretion vary over time and is influenced by developmental factors. (author)

  5. Use of immunoradiometric analysis to determine Rickettsia antigens in cell cultures and chick embryos

    Energy Technology Data Exchange (ETDEWEB)

    Prozorovskiy, S.V.; Alekseeva, N.V.; Knyazeva, E.N.; Ignatovich, V.F.; Barkhatova, O.T.

    1984-02-01

    A modification of an immunoradiometric analysis to determine Rickettsia antigens in various biological substrates was studied, using rickettsious diagnostricums, egg and cell cultures of Rickettsia. The method was highly sensitive for the determination of minimal quantities of antigens in these substrates. The method appears to be promising for studies related to the detection of microorganisms and their antigens. 5 references.

  6. Direct 125I-radioligand assays for serum progesterone compared with assays involving extraction of serum

    International Nuclear Information System (INIS)

    Ratcliffe, W.A.; Corrie, J.E.T.; Dalziel, A.H.; Macpherson, J.S.

    1982-01-01

    Two direct radioimmunoassays for progesterone in 50 μL of unextracted serum or plasma with assays involving extraction of serum were compared. The direct assays include the use of either danazol at pH 7.4 or 8-anilino-1-naphthalenesulfonic acid at pH 4.0 to displace progesterone from serum binding-proteins. Progesterone is then assayed by using an antiserum to a progesterone 11α-hemisuccinyl conjugate and the radioligand 125 I-labeled progesterone 11α-glucuronyl tyramine, with separation by double-antibody techniques. Direct assays with either displacing agent gave good analytical recovery of progesterone added to human serum, and progesterone values for patients' specimens correlated well (r > 0.96) with results of assays involving extraction of serum. Precision was similar with each displacing agent over the working range 2.5-100 nmol/L and superior to that of extraction assays. We conclude that these direct assays of progesterone are analytically valid and more robust, precise, and technically convenient than many conventional methods involving extraction of serum

  7. Evaluation of the Ramco kit for serum ferritin assay

    Energy Technology Data Exchange (ETDEWEB)

    Dempster, W S; Knight, G J [Red Cross War Memorial Children' s Hospital, Cape Town (South Africa). Department of Paediatrics and Child Health; Jacobs, P [Cape Town Univ. (South Africa). Dept. of Haematology

    1979-12-22

    The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6..mu..g/l to greater than 2 000 ..mu..g/l there was a correlation coefficient between the two methods of 0,8284 (P smaller than 0,001). It is concluded that the Ramco kit is suitable for use in clinical practice.

  8. An evaluation of the Ramco kit for serum ferritin assay

    International Nuclear Information System (INIS)

    Dempster, W.S.; Knight, G.J.; Jacobs, P.

    1979-01-01

    The determination of serum ferritin levels may be of diagnostic importance in medicine. To establish whether values obtained using a commercially available kit (Ramco) were adequate for this purpose, a comparison was undertaken using a two-site immunoradiometric assay that had been developed and standardized in our laboratories. Over the range 6μg/l to greater than 2 000 μg/l there was a correlation coefficient between the two methods of 0,8284 (P smaller than 0,001). It is concluded that the Ramco kit is suitable for use in clinical practice

  9. Immunoradiometric assay of a novel proliferation marker: tumour polypeptide specific antigen in breast cancer management in north India

    International Nuclear Information System (INIS)

    Phanna-Hazra, P.; Sharma, U.; Gupta, K.K.; Bhatnagar, V.; Idnani, R.; Gangwar, P.K.; Hazra, D.K.

    2004-01-01

    Tissue Polypeptide Specific Antigen (TPS) is a novel tumour marker defined by the monoclonal antibody M3 ,discovered by Bjorklund,which is claimed to be a proliferation marker, and belonging to the cytokeratin 8-18 family. M3 defines this antigen in particular out of a group of Tissue Polypeptide antigens (TPA) charecterised by the same Swedish group and was claimed to be a pancarcinoma antigen reportedly being elevated in several different cancers in the European literature.Pancarcinoma markers are of interest in relation to cancer detection as well as for assessing therapy and prognosis.Pancarcinoma antigens are also of interest for radiobioconjugate immunotargetting both for diagnosis as well as for therapy. There were no reports on this marker in an Indian population and therefore this study was initiated at two institutions in Meerut and Agra, both in the northern state of Uttar Pradesh. In addition to 250 healthy controls, 288 cases of breast cancer were studied .In addituion benign disorders were studied: breast fibroadenosis 16, breast fibro adenoma 5, breast abscess 4. TPS levels were determined by an immunoradiometric assay. In controls all but 4 had values less than 80 Units/1,the upper normal level quoted by Bjorklund.The relationship of the serum levels of the markers to histological grade and anatomical stage of the tumour were studied. In addition several of the cases underwent therapy with chemotherapy /radiotherapy/surgery or combinations thereof. The response to treatment during follow up was categorized as Complete emission(CR),Partial Remission (PR)Stable Disease(SD), Progressive Disease(PD)and recurrence (R) by the respective clinicians using standard criteria. In the cancer subjects there was a close correlation of TPS elevation with anatomical stage. 10 cases belonged to stage 1 with TPS levels 176.1+-103.94 Units/L ,61 to stage II(TPS levels 206.45 +-168.23).,79 to stage Ilia (TPS 251.5+-168.53),83 to stage IIIB (TPS 537.35+- 691.71),and 55

  10. Evaluation of a radioreceptor assay for TSH receptor autoantibodies

    Energy Technology Data Exchange (ETDEWEB)

    Rootwelt, K.

    1988-02-01

    A commercial radioreceptor assay for TSH receptor autoantibodies (TRAb), based on solubilized porcine receptor and purified radio-iodinated bovine TSH, was tested in 264 subjects with a variety of thyroid disorders. The sensitivity of the assay for the detection of hyperthyroid Graves' disease was 91%. The assay specificity for Graves' disease was 95%. With the exception of one patient with Hashimoto's disease and one patient with de Quervain's subacute thyroiditis no subjects other than Graves' patients had detectable TRAb. Thus purely blocking TSII receptor autoantibodies were not detected with the assay. One female with thyroxine-treated idiopathic primary hypothyroidism who had given birth to two children with transiently elevated TSH, was found to have a circulating TSH-binding substance that resulted in an abnormally negative TRAb value, and highly discrepant results when TSH was measured with a double antibody TSH radioimmunoassay and an immunoradiometric assay. The TSH-binding substance was precipitated like a protein, but was not IgG. Similar findings have not previously been reported.

  11. Development of kits for radioimmunometric assays for tumour markers. RC 9823/RB. Progress report from 12/97 to 06/99

    International Nuclear Information System (INIS)

    Robles, A.M.

    1999-01-01

    The purpose of the report is to inform the activities held under the RC 9823/RB from december/1997 to June/1999 with reagents distributed by the coordinator of the project (free and total PSA). The objective of the work was to get the capacity to make reliable diagnosis of PSA and to understand what is being evaluated with PSA reagents, to develop immunoradiometric assays for PSA free and total and to optimize the conditions of these assays so as to be able to be used as a diagnostic tool as well as reference standard

  12. Immunoradiometric quantitation of tissue plasminogen activator-related antigen in human plasma: crypticity phenomenon and relationship to plasma fibrinolysis

    International Nuclear Information System (INIS)

    Wun, T.C.; Capuano, A.

    1987-01-01

    A two-site immunoradiometric assay for tissue plasminogen activator (tPA) antigen has been developed using immunoaffinity purified antibody. Various treatments enhanced the detection of tPA antigen in the plasma samples. Maximum detection was obtained by acidification of plasma to pH 4.8 to 6.5 or addition of 0.5 mol/L of L-lysine or L-arginine. Acidification or addition of lysine to plasma is also required for maximum immunoadsorption of plasma tPA antigen on anti-tPA-Ig-sepharose. These results indicate that plasma tPA antigen is partially cryptic to antibody in untreated plasma. The plasma tPA antigen isolated by immunoadsorption of either untreated plasma or acidified plasma on anti-tPA-Ig-sepharose consists mainly of a 100-kd plasminogen activator species as determined by fibrin-agar zymography. The 100-kd activity is possibly a tPA:inhibitor complex. A standardized sample preparation method was conveniently adopted by mixing 3 vol of plasma and 1 vol of 2 mol/L of L-lysine for the assay. Reconstitution and recovery studies showed that the method is specific and permits full detection of both free tPA and tPA:inhibitor complex. The validity of the assay is further supported by the finding that the spontaneous plasma fibrinolysis previously demonstrated to be dependent on plasma tPA antigen is correlated with tPA antigen content. Using the standardized assay, we found that tPA antigen concentrations in 16 blood bank plasmas are equivalent to 3.7 to 20 ng of 60 kd tPA/mL. In all the plasma tested, more than half of the antigen is undetected unless the plasma is treated as described above

  13. Immunoradiometric quantitation of tissue plasminogen activator-related antigen in human plasma: crypticity phenomenon and relationship to plasma fibrinolysis

    Energy Technology Data Exchange (ETDEWEB)

    Wun, T.C.; Capuano, A.

    1987-05-01

    A two-site immunoradiometric assay for tissue plasminogen activator (tPA) antigen has been developed using immunoaffinity purified antibody. Various treatments enhanced the detection of tPA antigen in the plasma samples. Maximum detection was obtained by acidification of plasma to pH 4.8 to 6.5 or addition of 0.5 mol/L of L-lysine or L-arginine. Acidification or addition of lysine to plasma is also required for maximum immunoadsorption of plasma tPA antigen on anti-tPA-Ig-sepharose. These results indicate that plasma tPA antigen is partially cryptic to antibody in untreated plasma. The plasma tPA antigen isolated by immunoadsorption of either untreated plasma or acidified plasma on anti-tPA-Ig-sepharose consists mainly of a 100-kd plasminogen activator species as determined by fibrin-agar zymography. The 100-kd activity is possibly a tPA:inhibitor complex. A standardized sample preparation method was conveniently adopted by mixing 3 vol of plasma and 1 vol of 2 mol/L of L-lysine for the assay. Reconstitution and recovery studies showed that the method is specific and permits full detection of both free tPA and tPA:inhibitor complex. The validity of the assay is further supported by the finding that the spontaneous plasma fibrinolysis previously demonstrated to be dependent on plasma tPA antigen is correlated with tPA antigen content. Using the standardized assay, we found that tPA antigen concentrations in 16 blood bank plasmas are equivalent to 3.7 to 20 ng of 60 kd tPA/mL. In all the plasma tested, more than half of the antigen is undetected unless the plasma is treated as described above.

  14. Plasma erythropoietin by high-detectability immunoradiometric assay in untreated and treated patients with polycythaemia vera and essential thrombocythaemia

    Energy Technology Data Exchange (ETDEWEB)

    Carneskog, J.; Kutti, J.; Wadenvik, H. [Univ. of Goeteborg, Sahlgrenska Univ. Hospital, Dept. of Medicine, Haematology Section (Sweden); Lundberg, P.A.; Lindstedt, G. [Univ. of Goeteborg, Sahlgrenska Univ. Hospital, Dept. of Clinical Chemistry and Transfusion Medicine (Sweden)

    1998-12-31

    By using an immunoradiometric method with a stated detection limit of {<=}1 IU/l (stated normal reference limit in adults 3.7-16 IU/l) we determined EDTA-plasma erythropoietin (EPO) in 58 patients with polycythaemia vera (PV) and 49 patients with essential thrombocythaemia (ET). At the time of blood sampling, 20 of the PV patients were newly diagnosed and untreated, 23 were treated by phlebotomy only, and 30 also received myelosuppressive treatment (with 32P, hydroxyurea of alpha-interferon). Of the ET patients 24 were untreated and 28 received myelosuppressive therapy. For comparison plasma EPO was also determined in 10 patients with pseudopolycythaemia (PP). In this latter group the results for plasma EPO agreed well with the cited normal reference limits. The majority of untreated PV patients (12/20) had undetectable plasma EPO concentration, and the remainder all had values below the lower normal reference limit. Plasma EPO in PV was not significantly influenced by phlebotomy therapy. Twelve of the 24 untreated ET patients (50%) had plasma EPO values below the reference interval (undetectable in 2 patients). The mean EPO concentration was significantly lower in PV patients receiving phlebotomy therapy than in patients with untreated ET. In the total material of PV and ET treated with myelosuppressive agents the PV patients showed significantly lower values for EPO concentration than did patients with ET. The present results support the view that EPO measurements by high-detectability methods are diagnostically useful and should be included in the panel of new criteria for the diagnosis of PV. (au) 20 refs.

  15. Microsomal aryl hydrocarbon hydroxylase comparison of the direct, indirect and radiometric assays

    International Nuclear Information System (INIS)

    Denison, M.S.; Murray, M.; Wilkinson, C.F.

    1983-01-01

    The direct fluorometric assay of aryl hydrocarbon hydroxlyase has been compared to the more commonly used indirect fluorometric and radiometric assays. Although rat hepatic microsomal activities measured by the direct assay were consistently higher than those obtained by the other assays, the relative changes in activity following enzyme induction and/or inhibition were similar. The direct assay provides an accurate and rapid measure of aryl hydrocarbon hydroxylase activity and avoids several problems inherent in the indirect and radiometric assays. 2 tables

  16. Random assay in radioimmunoassay: Feasibility and application compared with batch assay

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jung Min; Lee, Hwan Hee; Park, Sohyun; Kim, Tae Sung; Kim, Seok Ki [Dept. of Nuclear MedicineNational Cancer Center, Goyang (Korea, Republic of)

    2016-12-15

    The batch assay has been conventionally used for radioimmunoassay (RIA) because of its technical robustness and practical convenience. However, it has limitations in terms of the relative lag of report time due to the necessity of multiple assays in a small number of samples compared with the random assay technique. In this study, we aimed to verify whether the random assay technique can be applied in RIA and is feasible in daily practice. The coefficients of variation (CVs) of eight standard curves within a single kit were calculated in a CA-125 immunoradiometric assay (IRMA) for the reference of the practically ideal CV of the CA-125 kit. Ten standard curves of 10 kits from 2 prospectively collected lots (pLot) and 85 standard curves of 85 kits from 3 retrospectively collected lots (Lot) were obtained. Additionally, the raw measurement data of both 170 control references and 1123 patients' sera were collected retrospectively between December 2015 and January 2016. A standard curve of the first kit of each lot was used as a master standard curve for a random assay. The CVs of inter-kits were analyzed in each lot, respectively. All raw measurements were normalized by decay and radioactivity. The CA-125 values from control samples and patients' sera were compared using the original batch assay and random assay. In standard curve analysis, the CVs of inter-kits in pLots and Lots were comparable to those within a single kit. The CVs from the random assay with normalization were similar to those from the batch assay in the control samples (CVs % of low/high concentration; Lot1 2.71/1.91, Lot2 2.35/1.83, Lot3 2.83/2.08 vs. Lot1 2.05/1.21, Lot2 1.66/1.48, Lot3 2.41/2.14). The ICCs between the batch assay and random assay using patients' sera were satisfactory (Lot1 1.00, Lot2 0.999, Lot3 1.00). The random assay technique could be successfully applied to the conventional CA-125 IRMA kits. The random assay showed strong agreement with the batch assay. The

  17. Evaluation of some magnetizable immunosorbents in radioimmunoassays and immunoradiometric assays of hormones

    International Nuclear Information System (INIS)

    Jyotsna, N.; Kadwad, V.; Sivaprasad, N.; Nirmala, V.; Pal, N.; Singh, Y.; Karir, T.; Chouthkantiwar, V.; Paradkar, S.

    1996-01-01

    Immunoassays are now indispensable clinical tools in many laboratories. An essential requirement for achieving reliable assays is an efficient and clean method for separating the immune complexes from the unreacted reagents. The development of a wide variety of solid phase separation methods has contributed significantly towards the reliability and simplification of immunoassays. Antibody coated macro one-piece surfaces like plastic beads or tubes are very popular but require great skill and control at all stages of manufacture. On the other hand, finely divided supports especially magnetizable particles are cheaper and simpler to develop. A variety of materials have been used in immunoassays. Black iron oxide Fe 3 O 4 is the most commonly used material and it is generally coated with polymeric materials like polymerized alkyl silanes, m-diaminobenzene, polyacrylamide, polyacrolein, or cellulose to facilitate covalent coupling of the antibodies. In this project we have evaluated some magnetizable particles for use in RIAs and IRMAs of hormones. The particles include Fe 3 0 4 , silane coated iron oxide, polyacrolein coated iron oxide and magnetizable cellulose. Second antibody (anti rabbit IgG.) was coupled to the particles for use in RIA of T 3 , T 4 , HCG, LH and progesterone, while monoclonal antibodies were coupled for the IRMAs of TSH, FSH and prolactin (hPrl). The influence of conditions such as reaction time, ratio of antibody to particles, and stability of the adsorbents and assay performance have been studied. For developing IRMAs for TSH, FSH and prolactin, monoclonal antibodies for each of these hormones were tested using magnetizable cellulose as the solid phase. We have also prepared silanized Fe 3 0 4 particles using Hungarian magnetite particles, and also prepared magnetizable cellulose by a simple grinding process. Both these materials are being tried out in different assays. Preliminary results have been encouraging. (author). 7 refs, 3 figs, 9 tabs

  18. Determination of free insulin-like growth factor-I in human serum

    DEFF Research Database (Denmark)

    Frystyk, J.; Skjærbæk, C.; Ivarsen, P.

    2001-01-01

    Two fundamentally different methods are currently used for the determination of free insulin-like growth factor-I (IGF-I): ultrafiltration by centrifugation (UF) and direct immunoradiometric assay (IRMA). The aim was to evaluate a commercial IRMA (DSL, Webster, TX, USA) and to compare it with UF....

  19. Direct assay for urine cortisol with cortisol kit TFB

    Energy Technology Data Exchange (ETDEWEB)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki [Yamagata Univ. (Japan). Hospital

    2002-05-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 {mu}l of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  20. Direct assay for urine cortisol with cortisol kit TFB

    International Nuclear Information System (INIS)

    Manaka, Yukiko; Watanabe, Michiko; Hosoya, Takaaki

    2002-01-01

    We examined Cortisol Kit TFB for direct assay of urine cortisol. And the multiplication by dilution factor of urine cortisol values in this kit was examined. The coefficient of correlation of cortisol levels (46 urine samples) between Cortisol Kit TFB and Chemilumi ACS-Cortisol II, which is another kit for direct assay of urine cortisol, was r=0.858, y=1.86x+38.2 (p<0.001). There were differences between the both cortisol levels of each urine sample in spite of the good coefficient of correlation. The urine cortisol values obtained from the standard curve in addition of 50 μl of zero standard were 50-80% of the values obtained from the standard curve in the package insert. These results suggest that the specificity of the antibodies of both direct assay kits for urine cortisol may be different each other, and the multiplication by 1.09, the dilution factor due to the addition of zero standard to only urine sample, is unnecessary although it is indispensable for urine samples to add zero standard. Cortisol Kit TFB was very convenient for its easy assay procedure and short incubation. (author)

  1. Characterization of monoclonal antibodies directed against human thyroid stimulating hormone

    International Nuclear Information System (INIS)

    Soos, M.; Siddle, K.

    1982-01-01

    Monoclonal antibodies directed against human thyroid stimulating hormone (TSH) were obtained from hybrid myelomas, following fusion of mouse NSI myeloma cells with mouse spleen cells. Ten different antibodies were obtained from 4 separate fusions. Eight antibodies were of the IgG 1 subclass. Affinities of antibodies for TSH were in the range 2 x 10 8 -5 x 10 10 M -1 . Five of the antibodies were specific for TSH and did not react with LH, FSH or hCG. The remaining antibodies reacted with all these hormones and were assumed to recognise their common (α) subunit. The 5 specific antibodies fell into 3 subgroups recognising distinct antigenic determinants, whereas the 5 non-specific antibodies recognised a single determinant or closely related set of sites. It is concluded that these antibodies should be valuable reagents for use in sensitive and specific two-site immunoradiometric assays. (Auth.)

  2. Detection of circulating immune complexes by Raji cell assay: comparison of flow cytometric and radiometric methods

    International Nuclear Information System (INIS)

    Kingsmore, S.F.; Crockard, A.D.; Fay, A.C.; McNeill, T.A.; Roberts, S.D.; Thompson, J.M.

    1988-01-01

    Several flow cytometric methods for the measurement of circulating immune complexes (CIC) have recently become available. We report a Raji cell flow cytometric assay (FCMA) that uses aggregated human globulin (AHG) as primary calibrator. Technical advantages of the Raji cell flow cytometric assay are discussed, and its clinical usefulness is evaluated in a method comparison study with the widely used Raji cell immunoradiometric assay. FCMA is more precise and has greater analytic sensitivity for AHG. Diagnostic sensitivity by the flow cytometric method is superior in systemic lupus erythematosus (SLE), rheumatoid arthritis, and vasculitis patients: however, diagnostic specificity is similar for both assays, but the reference interval of FCMA is narrower. Significant correlations were found between CIC levels obtained with both methods in SLE, rheumatoid arthritis, and vasculitis patients and in longitudinal studies of two patients with cerebral SLE. The Raji cell FCMA is recommended for measurement of CIC levels to clinical laboratories with access to a flow cytometer

  3. A new method for the production of a magnetic immunosorbent used in radioimmunoassay and immunoradiometric assay

    International Nuclear Information System (INIS)

    Toth, G.; Keszei, V.; Sarandi, I.

    1994-01-01

    A method has been developed enabling the direct coupling of first or second antibody to finely dispersed magnetite (Fe 3 O 4 ). The immunosorbent thus produced was applied in various radioimmunoassay systems (T3, T4, TSH, Cortisol) for the separation of bound and free antigens. The elimination of the need for 'precoating' the magnetic particles with a polymer as several advantages. One of them lies in the ease of one-step production of the immunosorbent and other is the high antibody/magnetic ratio. The influence of the concentration of the immunosorbent and detergent (TWEEN 20 or TRITON X-100) on the assay parameters (Bo, NSB, etc.) has been systematically investigated and the optimum concentration of the magnetizable particles and detergent has been determined. The reliability of magnetic separation has been validated by comparing it with the conventional PEG separation method. (author) 13 refs.; 17 figs.; 9 tabs

  4. A comparative study in three commercial kits of radioligand assay for GAD-Ab

    International Nuclear Information System (INIS)

    Yang Yehua; Zhou Zhiguang; Huang Gan; Yang Feike; Li Zhangwei

    2006-01-01

    Objective: To provide data for perfect selection of glutamic acid decarboxylase antibodies (GAD-Ab) assay commercial kits. Methods: The sera of 88 titer-graded samples by radioligand assay (RLA) were measured with two types of enzyme-linked immunosorbent assay (ELISA) kits and one type of immunoradiometric assay (IRMA) kit for GAD-Ab in order to test their consistency with RLA. Another 140 diabetic sera were measured with RLA and screened by a type of suitable kit to search the cutoff point for discriminating patients who needed rechecking. Results: Compared with RLA, concordance ratio of 3 kits: Medizym kit(75%) > RSR kit(73.9%) > Biomerica kit(62.5%); Kappa value: Medizym kit (0.408, common) > RSR kit (0.405, common) > Biomerica kit (0.185, failing); correlation to RLA index: RSR kit (r= 0.992) > Medizym kit(r= 0. 791 ) > Biomerica kit (r = -0. 055); area under the receiver operating characteristic (ROC) curve: Medizym kit (0.812) > RSR kit (0. 727 ) > Biomerica kit (0.666). Conclusions: The efficiencies of RSR kit and Medizym kit are good. Serum concentration between 0.25-0.99 U/ml measured by RSR kit is suggested to further recheck by RLA. (authors)

  5. Limitations of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) for detection of filarial antigens in serum

    International Nuclear Information System (INIS)

    Hamilton, R.G.; Alexander, E.; Adkinson, N.F.

    1984-01-01

    The performance of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) was examined for quantitation of filarial antigens (Brugia malayi and Dirofilaria immitis) in serum from infected human and animal hosts and non-infected controls. Multiple PEG concentrations were employed to determine the level of non-specific binding (NSB) in non-exposed human sera (NEHS) containing no filarial antigen. The NSB observed when 3 different 125 I-labelled IgG antibodies were added to 26 NEHS varied 3-fold and was correlated significantly with total serum IgM (r = 0.80, P 2 fragment of the 125 I-labelled antibody was used, but the correlation of NSB with total serum IgM remained significant (r = 0.57, P < 0.01). The presence of rheumatoid factor in NEHS sera also significantly increased NSB by an average of 3-fold. These effects eliminated the assay's ability to detect in sera from infected hosts filarial antigen the presence of which could be readily demonstrated by an immunoradiometric assay. The RIPEGA's precision (intra-assay coefficient of variation (CV) = 21% at 35% Bsub(max)) and reproducibility (inter-assay CV = 29% at 35% Bsub(max)) are less satisfactory than many alternative immunoassays. (Auth.)

  6. Immunoassay of serum polypeptide hormones by using 125I-labelled anti(-immunoglobulin G) antibodies.

    Science.gov (United States)

    Beck, P; Nicholas, H

    1975-03-01

    1. A technique for indirectly labelling antibodies to polypeptide hormones, by combining them with radioactively labelled anti-(immunoglobulin G) is described. (a) 125I-labelled anti-(rabbit immunoglobulin G) and anti-(guinea-pig immunoglobulin G) antibodies with high specific radioactivity were prepared after purification of the antibodies on immunoadsorbents containing the respective antigens. (b) Rabbit immunoglobulin G antibodies to human growth hormone, porcine glucagon and guinea-pig immunoglobulin G antibodies to bovine insulin and bovine parathyroid hormone were combined with immunoadsorbents containing the respective polypeptide hormone antigen. (c) The immunoglobulin G antibodies to the polypeptide hormones were reacted with 125-I-labelled anti-(immunoglobulin G) antibodies directed against the appropriate species of immunoglobulin G,and the anti-hormone antibodies were combined with the hormone-containing immunoadsorbent. (d) 125I-labelled anti-(immunoglobulin G) antibodies and anti-hormone antibodies were simultaneously eluted from the hormone-containing immunoadsorbent by dilute HCl, pH 2.0. After elution the anti-(immunoglobulin G) antibodies and antihormone antibodies were allowed to recombine at pH 8.0 and 4 degrees C. 2. The resultant immunoglobulin G-anti-immunoglobulin G complex was used in immunoradiometric (labelled antibody) and two-site assays of the respective polypeptide hormone. 3. By using these immunoassays, concentrations down to 90pg of human growth hormone/ml, 100 pg of bovine insulin/ml, 80 pg of bovine parathyroid hormone/ml and 150 pg of glucagon/ml were readily detected. Assays of human plasma for growth hormone and insulin by these methods showed good agreement with results obtained by using a directly 125I-labelled anti-hormone antibody in an immunoradiometric assay of human growth hormone or by radioimmunoassay of human insulin. 4. The method described allows immunoradiometric or two-site assays to be performed starting with as

  7. Development of simple immunoradiometric assay kits for measurement of Prostate Specific Antigen (PSA)

    International Nuclear Information System (INIS)

    Najafi, R.; Zarsav, P.; Pourabdi, M.; Moharamzadeh, M.; Mahdiani, B.

    1999-01-01

    The report summarizes our results obtained in the field of PSA IRMA kits development. In these experiments, we used Avidin-Biotin technology for coating of antibodies on beads/tubes and studied various parameters, such as investigation of different types of tubes, incubation time, volume of samples etc., as well as comparing two types of Mabs of PSA (free and total) for coating on the surface of bead/tube and obtaining optimized requirements to achieve reliable and simplified assays of PSA (free and total) in serum. (author)

  8. Interpretation of growth hormone provocative tests

    DEFF Research Database (Denmark)

    Andersson, A M; Orskov, H; Ranke, M B

    1995-01-01

    To compare interpretations of growth hormone (GH) provocative tests in laboratories using six different GH immunoassays (one enzymeimmunometric assay (EIMA, assay 1), one immunoradiometric assay (IRMA, assay 5), one time-resolved fluorimmunometric assay (TRFIA, assay 3) and three radioimmunoassays...

  9. Quantitative immunoassays for diagnosis and carrier detection in cystic fibrosis

    International Nuclear Information System (INIS)

    Bullock, S.; Hayward, C.; Manson, J.; Brock, D.J.H.; Raeburn, J.A.

    1982-01-01

    Quantitative immunoprecipitation and immunoradiometric assays have been developed for a protein present in the serum of cystic fibrosis homozygotes, and to a lesser extent in the serum of heterozygotes. When tested on a panel of sera from 14 cystic fibrosis patients, 29 heterozygotes and 23 controls, the immunoprecipitation assay allowed correct assignments to be made on 94% of occasions with one batch of antiserum and 95% with another. With the same panel of sera, the immunoradiometric assay allowed 94% correct assignments. It is suggested that such accuracy is the maximum that can be expected in the present state of knowledge of cystic fibrosis. (author)

  10. Concepts for the assay of unbound thyroxine (FT4) and thyroxine binding globulin (TBG)

    International Nuclear Information System (INIS)

    Odstrchel, G.; Hertl, W.; Ward, F.B.; Travis, K.; Lindner, R.E.; Mason, R.D.

    1977-01-01

    Two new concepts for the assay of thyroid related substances are presented. One assay (FT 4 ) is based on a kinetic measurement of T 4 as it desorbs from binder proteins onto solid-phase T 4 antibody. This reaction can be described by a second order rate equation; r = k (IMA) (FT 4 ). The assay is rapid (2 hours) and gives good agreement (sigma = 0.92) with equilibrium dialysis and a normal range of 0.9 - 2.3 ng/dl. This assay uses a small sample size (25 μl) and is unaffected by drugs such as aspirin and dilantin. Pregnant and estrogen treated women gave normal FT 4 values. A new method for the measurement of functionally active TEG is also presented. In this case the labeled T 4 is partitioned between bovine serum albumin and the patient's samples. The complex is then removed from solution by solid-phase anti-TBG. A curve remiscent of an immunoradiometric assay is obtained. The assay has a sensitivity of 4 μg/ml and is unaffected by aspirin, dilantin or the patient's T 4 concentrations. Correlation with 'rocket' electrophoresis is 0.90. The normal range was 20 +- 7 μg/ml with pregnant women giving values greater than 30 μg/ml. Five hereditary deficient patients gave a value equivalent to zero TBG concentration. (orig.) [de

  11. Investigation into the dissolution and direct assay of high-fired plutonium dioxide

    International Nuclear Information System (INIS)

    Patterson, J.K.

    1976-01-01

    A fusion-melt and dissolution assay method has been developed and tested for the quantitative analysis of high-fired plutonium dioxide. The method employs fusion of the plutonium dioxide at temperatures greater than the melting point of an eutectic mixture of potassium pyrosulfate plus sodium peroxide. The resultant melt is then titrated directly by either controlled potential coulometry or a gravimetric titration, using standardized ceric sulfate as the titrant. It has been concluded from these investigations that by using the techniques described, high-fired plutonium dioxide (stochiometric) can be quantitatively dissolved and assayed to a degree heretofore beyond the state-of-the-art, while showing direct traceability to the Federal standards. After fusion, the dissolution and direct assay is applicable to existing routine analytical procedures. The method was designed so as to minimize physical handling, simplify the chemical operations, and maximize the personal safety of the analyst at an appreciable cost savings per analysis

  12. Excess antibody immunoassays for rat glandular kallikreins. Measurement of kallikrein from different organs in the presence of cross-reacting antigens

    International Nuclear Information System (INIS)

    Johansen, L.; Oerstavik, T.B.; Holck, M.; Nustad, K.

    1983-01-01

    An immunoradiometric assay has previously been developed for measurement of rat glandular kallikrein. In the present paper, further studies on the specificity and sensitivity of the method are described. Problems of interference of immunologically cross-reacting antigens were overcome by proper preabsorption of the antibody. A method was thus established in which enzymatic activity of the immunoreactive kallikrein could be measured even in the presence of enzymes sharing immunological determinants and substrate specificity with kallikrein. Two variants of the immunoradiometric assay have been evaluated. A simplified version with simultaneous addition of all reagents gave results equal to those obtained in the original assay. A further modification with delayed addition of the solid-phase antibody, gave considerable improvement in assay sensitivity. (Auth.)

  13. Comparison of the direct enzyme assay method with the membrane ...

    African Journals Online (AJOL)

    Comparison of the direct enzyme assay method with the membrane filtration technique in the quantification and monitoring of microbial indicator organisms – seasonal variations in the activities of coliforms and E. coli, temperature and pH.

  14. Direct Competitive Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Kohl, Thomas O; Ascoli, Carl A

    2017-07-05

    The competitive enzyme-linked immunosorbent assay (ELISA) (cELISA; also called an inhibition ELISA) is designed so that purified antigen competes with antigen in the test sample for binding to an antibody that has been immobilized in microtiter plate wells. The same concept works if the immobilized molecule is antigen and the competing molecules are purified labeled antibody versus antibody in a test sample. Direct cELISAs incorporate labeled antigen or antibody, whereas indirect assay configurations use reporter-labeled secondary antibodies. The cELISA is very useful for determining the concentration of small-molecule antigens in complex sample mixtures. In the direct cELISA, antigen-specific capture antibody is adsorbed onto the microtiter plate before incubation with either known standards or unknown test samples. Enzyme-linked antigen (i.e., labeled antigen) is also added, which can bind to the capture antibody only when the antibody's binding site is not occupied by either the antigen standard or antigen in the test samples. Unbound labeled and unlabeled antigens are washed away and substrate is added. The amount of antigen in the standard or the test sample determines the amount of reporter-labeled antigen bound to antibody, yielding a signal that is inversely proportional to antigen concentration within the sample. Thus, the higher the antigen concentration in the test sample, the less labeled antigen is bound to the capture antibody, and hence the weaker is the resultant signal. © 2017 Cold Spring Harbor Laboratory Press.

  15. Immunological measurements on the disappearance of creatine kinase MM from the circulation

    International Nuclear Information System (INIS)

    Wevers, R.A.; Landeghem, A.A.J. van; Mul-Steinbusch, M.W.F.J.; Bijdendijk, J.G.; Weerts, P.; Kloeg, P.; Soons, J.B.J.

    1983-01-01

    Both a two-site immunoradiometric assay and a two-site enzyme-linked immunosorbent assay for creatine kinase MM are described. Linearity, reproducibility and cross-reactivity of the assays are satisfactory. Creatine kinase MM incubated in a pH-controlled serum matrix loses its activity, but has its antigenic determinants affected as well. Of all the techniques used, only the immunoradiometric assay is capable of measuring part of the inactivated enzyme. Measurements with this assay on the sera of patients after a myocardial infarction show identical results for enzyme activity and creatine kinase protein quantity. The in vitro disappearance rate of creatine kinase activity is slow compared with the in vivo half-life of the enzyme. These two observations lead to the conclusion that creatine kinase is removed from the circulation long before it is inactivated in the blood stream. (Auth.)

  16. Development and optimization of a direct plaque assay for human and avian metapneumoviruses

    Science.gov (United States)

    Zhang, Yu; Wei, Yongwei; Li, Junan; Li, Jianrong

    2012-01-01

    The genus Metapneumovirus within the subfamily Pneumovirinae and family Paramyxoviridae includes only two viruses, human metapneumovirus (hMPV) and avian metapneumovirus (aMPV), which cause respiratory disease in humans and birds, respectively. These two viruses grow poorly in cell culture and other quantitation methods, such as indirect immuno-staining and immuno-fluorescent assays, are expensive, time consuming, and do not allow for plaque purification of the virus. In order to enhance research efforts for studying these two viruses, a direct plaque assay for both hMPV and aMPV has been developed. By optimizing the chemical components of the agarose overlay, it was found that both hMPV with a trypsin-independent F cleavage site and aMPV formed clear and countable plaques in a number of mammalian cell lines (such as Vero-E6 and LLC-MK2 cells) after 5 days of incubation. The plaque forming assay has similar sensitivity and reliability as the currently used immunological methods for viral quantitation. The plaque assay is also a more simple, rapid, and economical method compared to immunological assays, and in addition allows for plaque purification of the viruses. The direct plaque assay will be a valuable method for the quantitation and evaluation of the biological properties of some metapneumoviruses. PMID:22684013

  17. Comparison of pituitary and recombinant human thyrotropin standards in an immunoradiometric system; Comparacion de estandares de tirotropina de origen hipofisario y recombinante en un sistema immunoradiometrico

    Energy Technology Data Exchange (ETDEWEB)

    Blanca Fernandez, Silvia; Rodriguez Gonzalez, Julio Cesar; Nisembaum Alas, Amaparo; Sevy Gonzalez, O [Instituto Nacional de Endocrinologia, La Habana (Cuba)

    1999-12-31

    Results of two standards of human thyrotropin of pituitaries (B) and recombinant (C) origen supplied by the Instituto of pesquisas Energeticas y Nucleares, Brazil, were compared in our immunoradiometric reference system that use an human thyrotropin pituitary standard of local production (A). This work was supported by the International Atomic Energy Agency for an inter-regional comparison and set up of a reference standard

  18. Direct Assay of Filter Media following DEOX Testing

    International Nuclear Information System (INIS)

    R.P. Lind; J.J. Giglio; D.G. Cummings; M.W. Huntley; C.D. Morgan; K.J. Bateman; D.L. Wahlquist; D.A. Sell

    2007-01-01

    The direct assay of filter media by gamma spectrometry following DEOX testing has distinct advantages over analytical chemistry. Prior to using gamma spectrometry for the quantification of cesium (Cs-137), a calibration must be established with known sources since gamma spectrometry yields relative results. Quantitative analytical chemistry, in particular ICP-MS, has been performed on the filter media for comparison to the gamma spectrometry data. The correlation of gamma spectrometry to ICP-MS data is presented to justify the continued use of gamma spectrometry for filter media

  19. Concordance between results of somatostatin receptor scintigraphy with 111In-DOTA-DPhe1-Tyr3-octreotide and chromogranin A assay in patients with neuroendocrine tumours

    International Nuclear Information System (INIS)

    Rodrigues, Margarida; Gabriel, Michael; Heute, Dirk; Putzer, Daniel; Virgolini, Irene; Griesmacher, Andrea

    2008-01-01

    Somatostatin receptor scintigraphy (SRS) and chromogranin A (CgA) assay have successfully been implemented in the clinical work-up and management of neuroendocrine tumour (NET) patients. However, there is still a lack of studies comparing results in these patients. Our aim was to compare directly in NET patients SRS and CgA assay results with special regard to tumour features such as grade of malignancy, primary origin, disease extent and function. One hundred twenty consecutive patients with histological confirmed NETs were investigated with 111 In-DOTA-DPhe 1 -Tyr 3 -octreotide ( 111 In-DOTA-TOC) SRS and CgA immunoradiometric assay. Tumours were classified by cell characteristics [well-differentiated NETs, well-differentiated neuroendocrine carcinomas, poorly differentiated neuroendocrine carcinomas (PDNECs)], primary origin (foregut, midgut, hindgut, undetermined), disease extent (limited disease, metastases, primary tumour and metastases) and functionality (secretory, nonsecretory). SRS was positive in 107 (89%) patients; CgA levels were increased in 95 (79%) patients. Overall, concordance between SRS and CgA results was found in 84 patients. Positive SRS but normal CgA level were found in 24 patients, with higher prevalence (p 111 In-DOTA-TOC SRS proved to be more sensitive than CgA in NETs patients. Tumour differentiation, disease extent and presence of liver metastases impact both SRS and CgA results, whereas nonsecretory activity is a negative predictor of only CgA increase. PDNECs and hindgut origin of tumours predispose to discrepancies with negative SRS but increased CgA levels. (orig.)

  20. Kinetics of two-site immunoradiometric ('sandwich') assays

    International Nuclear Information System (INIS)

    Rodbard, D.; Feldman, Y.; Jaffe, M.L.; Miles, L.E.M.

    1978-01-01

    The mathematical model of the ideal two-site IRMA developed in the accompanying report, which assumes that both the first (solid phase) and second (labeled) antisera are 'homogeneous', fails to provide an explanation for the frequent occurrence of a paradoxical fall in the dose-response curve in the high-dose region ('high-dose hook effect'). Accordingly, the model has been extended in an attempt to provide a theoretical basis for these phenomena. Two mechanisms were considered: (A) heterogeneity of the first antiserum (which is bound to the solid phase), i.e. presence of two or more classes of sites with moderately to widely differing affinity constants; and (B) incomplete washing of the solid phase after the first reaction. This leads to an expanded system of five differential equations, five equations for conservation of mass, and fourteen rate constants. In the presence of a heterogeneous first antiserum, a high dose 'hook effect' will occur. Rapid dissociation of the ligand from the low affinity class of sites during the second 'wash' procedure will accentuate this effect. Thus, heterogeneity of binding sites is a sufficient explanation for the high-dose hook effect and is a likely mechanism in practice, since the antisera which are coupled to the solid phase have usually not been fractionated. The present studies also show that, even if dealing with homogeneous first antibody, one may still observe a high-dose hook effect if washing is incomplete after the first incubation with the antigen. Using computer simulation studies, factors affecting the magnitude of the 'high-dose hook effect' have been explored. (author)

  1. Direct assay of filter media following DEOX testing

    International Nuclear Information System (INIS)

    Westphal, B.R.; Lind, R.P.; Giglio, J.J.; Cummings, D.G.; Huntley, M.W.; Morgan, C.D.; Bateman, K.J.; Wahlquist, D.L.; Sell, D.A.

    2007-01-01

    The direct assay of filter media by gamma spectrometry following DEOX testing has distinct advantages over analytical chemistry. Prior to using gamma spectrometry for the quantification of cesium (Cs- 137), a calibration must be established with known sources since gamma spectrometry yields relative results. Quantitative analytical chemistry, in particular ICP-MS, has been performed on the filter media for comparison to the gamma spectrometry data. The correlation of gamma spectrometry to ICP-MS data is presented to justify the continued use of gamma spectrometry for filter media. (authors)

  2. Development of an assay for a biomarker of pregnancy and early fetal loss

    International Nuclear Information System (INIS)

    Canfield, R.E.; O'Connor, J.F.; Birken, S.; Krichevsky, A.; Wilcox, A.J.

    1987-01-01

    Human chorionic gonadotropin (hCG) is a glycoprotein hormone, secreted by the syncytiotrophoblast cells of the fertilized ovum, that enters the maternal circulation at the time of endometrial implantation. It is composed of two nonidentical subunits; α and β, with molecular weights of 14 kD and 23 kD, respectively. Human chorionic gonadotropin binds to the same receptor as hLH and displays the same biological response, namely, to stimulate the declining function of the corpus luteum to produce progestins and estrogen late in the menstrual cycle. The differences in the structures of hCG and hLH have been exploited to develop antibodies that can measure hCG specifically in the presence of hLH. Two-site antibody binding assays have been developed, based on a surface immunological concept of hCG epitopes, that involve four distinct regions to which antibodies against hCG can bind simultaneously. Antibody cooperative effects, in conjunction with kinetic advantages derived from the concentration factors by use of the sandwich assay technique (immunoradiometric assay, IRMA), have enabled development of extremely sensitive and specific measurement protocols for urinary hCG. The assay described herein permits the detection of pregnancy on an average 25.4 days after the first day of the preceding menses, as opposed to 29.5 days for conventional radioimmunoassay techniques. In addition, the greater sensitivity and specificity of this assay method has permitted the detection of episodes of fetal loss not detected by radioimmunoassay of urine specimens. A large scale epidemiological study is in progress using this assay technique as a way to identify pregnancies that are lost before becoming clinically apparent

  3. Quantum dot-linked immunosorbent assay (QLISA) using orientation-directed antibodies.

    Science.gov (United States)

    Suzuki, Miho; Udaka, Hikari; Fukuda, Takeshi

    2017-09-05

    An approach similar to the enzyme-linked immunosorbent assay (ELISA), with the advantage of saving time and effort but exhibiting high performance, was developed using orientation-directed half-part antibodies immobilized on CdSe/ZnS quantum dots. ELISA is a widely accepted assay used to detect the presence of a target substance. However, it takes time to quantify the target with specificity and sensitivity owing to signal amplification. In this study, CdSe/ZnS quantum dots are introduced as bright and photobleaching-tolerant fluorescent materials. Since hydrophilic surface coating of quantum dots rendered biocompatibility and functional groups for chemical reactions, the quantum dots were modified with half-sized antibodies after partial reduction. The half-sized antibody could be bound to a quantum dot through a unique thiol site to properly display the recognition domain for the core process of ELISA, which is an antigen-antibody interaction. The reducing conditions were investigated to generate efficient conjugates of quantum dots and half-sized antibodies. This was applied to IL-6 detection, as the quantification of IL-6 is significant owing to its close relationships with various biomedical phenomena that cause different diseases. An ELISA-like assay with CdSe/ZnS quantum dot institution (QLISA; Quantum dot-linked immunosorbent assay) was developed to detect 0.05ng/mL IL-6, which makes it sufficiently sensitive as an immunosorbent assay. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Direct fluorescence anisotropy assay for cocaine using tetramethylrhodamine-labeled aptamer.

    Science.gov (United States)

    Liu, Yingxiong; Zhao, Qiang

    2017-06-01

    Development of simple, sensitive, and rapid method for cocaine detection is important in medicine and drug abuse monitoring. Taking advantage of fluorescence anisotropy and aptamer, this study reports a direct fluorescence anisotropy (FA) assay for cocaine by employing an aptamer probe with tetramethylrhodamine (TMR) labeled on a specific position. The binding of cocaine and the aptamer causes a structure change of the TMR-labeled aptamer, leading to changes of the interaction between labeled TMR and adjacent G bases in aptamer sequence, so FA of TMR varies with increasing of cocaine. After screening different labeling positions of the aptamer, including thymine (T) bases and terminals of the aptamer, we obtained a favorable aptamer probe with TMR labeled on the 25th base T in the sequence, which exhibited sensitive and significant FA-decreasing responses upon cocaine. Under optimized assay conditions, this TMR-labeled aptamer allowed for direct FA detection of cocaine as low as 5 μM. The maximum FA change reached about 0.086. This FA method also enabled the detection of cocaine spiked in diluted serum and urine samples, showing potential for applications. Graphical Abstract The binding of cocaine to the TMR-labeled aptamer causes conformation change and alteration of the intramolecular interaction between TMR and bases of aptamer, leading to variance of fluorescence anisotropy (FA) of TMR, so direct FA analyis of cocaine is achieved.

  5. First direct fluorescence polarization assay for the detection and quantification of spirolides in mussel samples

    International Nuclear Information System (INIS)

    Otero, Paz; Alfonso, Amparo; Alfonso, Carmen; Araoz, Romulo; Molgo, Jordi; Vieytes, Mercedes R.; Botana, Luis M.

    2011-01-01

    Highlights: → A direct assay based in the binding of nAChR to spirolide toxins by FP is described. → A direct relationship between FP and 13-desMeC in the range of 10-500 nM is obtained. → FP is dependent on the 13, 19-didesMeC in a higher concentration range than 13-desMeC. → FP assay is a sensitive method to detect and quantify 13-desMeC in mussel samples. - Abstract: In 2009, we achieve the first inhibition FP assay to detect imine cyclic toxins. In the present paper we propose a new FP assay for direct quantify spirolides. This new method has resulted in significant improvement of sensitivity, rapidity and accessibility. In the method design, nicotinic acetylcholine receptor from Torpedo marmorata membranes labelled with a derivative of fluorescein was used. Spirolides, 13-desmethyl spirolide C (13-desMeC) and 13,19-didesmethyl spirolide C (13,19-didesMeC) were extracted and purified from cultures of the Alexandrium ostenfeldii dinoflagellate. Data showed the decrease of FP when toxin concentration was increased. Thus, a relationship between the FP units and the spirolides amount present in a sample was obtained. This direct assay is a reproducible, simple and very sensitive method with a detection limit about 25 nM for 13-desMeC and 150 nM for 13,19-didesMeC. The procedure was used to measure spirolides in mussel samples using an extraction and clean up protocol suitable for the FP assay. Results obtained show that this method is able to quantify 13-desMeC in the range of 50-350 μg kg -1 meat. Other liposoluble toxins did not interfere with the assay, proving a specific method. Moreover, the matrix do not affect in the range of toxin concentrations that involving risk of spirolides intoxication.

  6. First direct fluorescence polarization assay for the detection and quantification of spirolides in mussel samples

    Energy Technology Data Exchange (ETDEWEB)

    Otero, Paz; Alfonso, Amparo [Departamento de Farmacologia, Facultad de Veterinaria, Universidad de Santiago de Compostela, Campus Universitario s/n, 27002 Lugo (Spain); Alfonso, Carmen [CIFGA Laboratorio, Plaza de Santo Domingo, 1, 27001 Lugo (Spain); Araoz, Romulo; Molgo, Jordi [CNRS, Institut de Neurobiologie Alfred Fessard - FRC2118, Laboratoire de Neurobiologie et Developpement UPR3294, 1 Avenue de la Terrasse, 91198 Gif sur Yvette Cedex (France); Vieytes, Mercedes R. [Departamento de Fisiologia, Facultad de Veterinaria, Universidad de Santiago de Compostela, 27002 Lugo (Spain); Botana, Luis M., E-mail: luis.botana@usc.es [Departamento de Farmacologia, Facultad de Veterinaria, Universidad de Santiago de Compostela, Campus Universitario s/n, 27002 Lugo (Spain)

    2011-09-09

    Highlights: {yields} A direct assay based in the binding of nAChR to spirolide toxins by FP is described. {yields} A direct relationship between FP and 13-desMeC in the range of 10-500 nM is obtained. {yields} FP is dependent on the 13, 19-didesMeC in a higher concentration range than 13-desMeC. {yields} FP assay is a sensitive method to detect and quantify 13-desMeC in mussel samples. - Abstract: In 2009, we achieve the first inhibition FP assay to detect imine cyclic toxins. In the present paper we propose a new FP assay for direct quantify spirolides. This new method has resulted in significant improvement of sensitivity, rapidity and accessibility. In the method design, nicotinic acetylcholine receptor from Torpedo marmorata membranes labelled with a derivative of fluorescein was used. Spirolides, 13-desmethyl spirolide C (13-desMeC) and 13,19-didesmethyl spirolide C (13,19-didesMeC) were extracted and purified from cultures of the Alexandrium ostenfeldii dinoflagellate. Data showed the decrease of FP when toxin concentration was increased. Thus, a relationship between the FP units and the spirolides amount present in a sample was obtained. This direct assay is a reproducible, simple and very sensitive method with a detection limit about 25 nM for 13-desMeC and 150 nM for 13,19-didesMeC. The procedure was used to measure spirolides in mussel samples using an extraction and clean up protocol suitable for the FP assay. Results obtained show that this method is able to quantify 13-desMeC in the range of 50-350 {mu}g kg{sup -1} meat. Other liposoluble toxins did not interfere with the assay, proving a specific method. Moreover, the matrix do not affect in the range of toxin concentrations that involving risk of spirolides intoxication.

  7. Cell-patterned glass spray for direct drug assay using mass spectrometry

    International Nuclear Information System (INIS)

    Wu, Jing; Wang, Shiqi; Chen, Qiushui; Jiang, Hao; Liang, Shuping; Lin, Jin-Ming

    2015-01-01

    In this work, the establishment of a glass spray mass spectrometry (GS-MS) platform for direct cell-based drug assay was described. Cell co-culture, drug-induced cell apoptosis, proliferation analysis and intracellular drug absorption measurement were performed simultaneously on this specifically designed platform. Two groups of co-cultured cells (NIH-3T3/HepG2 and HepG2/MCF-7) were cultivated and they showed high viability within 3 days. The biocompatibility of the platform facilitated the subsequent bioassays, in which, cyclophosphamide (CPA) and genistein were used as the model drugs. The distinctions of cell apoptosis and proliferation between the mono-cultured and co-cultured cells were clearly observed and well explained by in situ GS-MS measurements. A satisfactory linearity of the calibration curve between the relative MS intensity and CPA concentrations was obtained using stable isotope labeling method (y = 0.16545 + 0.0985x, R"2 = 0.9937). The variations in the quantity of absorbed drug were detected and the results were consistent with the concentration-dependence of cell apoptosis. All the results demonstrated that direct cell-based drug assay could be performed on the stable isotope labeling assisted GS-MS platform in a facile and quantitative manner. - Highlights: • A versatile glass spray mass spectrometry (GS-MS) platform for direct cell-based drug assay was developed in this paper. • It has characteristics of the atmospheric pressure ionization method. • It is multifunctional for cell co-culture, bioassays, qualitative and quantitative intracellular drug absorption measurement. • GS-MS has the potential to increase the use of mass spectrometry in biological analysis.

  8. Kinetic Consideration of AFP irma assay

    International Nuclear Information System (INIS)

    Aly, M. A.; Moustafa, K.A.

    2003-01-01

    Alpha-fetoprotein (AFP) is a glycoprotein produced by the yolk sac and later by the fetal liver during pregnancy. When the neural tube is not properly formed, by the fetal liver during pregnancy. When the neural tube is not properly formed, large amounts of AFP pass into the amniotic fluid and reach the mother's blood. During pregnancy, the major interest in AFP determination in maternal serum and amniotic fluid is on the early diagnosis of fetal abnormalities. AFP also used as a tumor marker for hepatocellular carcinoma. There are many different techniques for measuring AFP in blood, but the more accurate one is the immunoassay technique. The kinetics of the interaction between AFP antigen and two matched antibodies, one labeled with radioactive isotope 1 25I (tracer) and the other is unlabelled and attached to a solid support (tube), are studied using the more recently, two sites (sandwich) immunoradiometric assay (IRMA) technique. We present here a method for determining the rate constants, using an advanced computer program (RKY), which based on the nelder-mead optimization principle. The rate constant, at three variable temperatures and three different antigen concentrations, as well as the half time of exchange (t 1/2 ) were calculated

  9. Quantitative assay for the measurement of immune responses directed against the human placenta

    Energy Technology Data Exchange (ETDEWEB)

    Davies, M; Sutcliffe, R G [Glasgow Univ. (UK)

    1982-02-12

    A quantitative in vitro immune assay based on the classical chromium release assay has been developed to detect immune responses directed against alien antigens expressed by the developing foetus and present on the maternal-facing surface of the human placenta. A plasma membrane fraction from the surface of the placenta was prepared and the vesicles thus formed were radiolabelled with /sup 51/Cr. The /sup 51/Cr-labelled vesicles, by various criteria, were found to be suitable for use as targets in a release assay. Further, by means of experimentally immunised animals, the target membranes were shown to be capable of detecting both cellular and humoral anti-placental activity.

  10. Direct microculture enzyme-linked immunosorbent assay for studying neural cells: oligodendrocytes.

    Science.gov (United States)

    Gard, A L; Warrington, A E; Pfeiffer, S E

    1988-05-01

    Oligodendrocyte development has been studied in a standardized primary microculture system initiated from day 20-21 fetal rat brain using a solid-phase enzyme-linked immunosorbent assay (ELISA) carried out directly on fixed cells (direct microculture ELISA). A highly reproducible dissociation procedure is described that allows careful control of the number of cells seeded per culture. At a seeding density of 1 x 10(5) cells/culture, up to 250 oligodendrocyte-generating microcultures consisting of 10-12% oligodendrocytes can be prepared from a single fetal rat brain, thereby permitting the simultaneous assay of multiple developmental parameters in sibling cultures. The validity of this method for quantifying myelinogenesis was established by comparing the results obtained by direct microculture ELISA with immunocytochemical counting of cells in parallel cultures. As few as 200 oligodendrocytes could be detected using a biotinylated anti-Ig and an avidin-urease conjugate detection system; CNP immunoreactivity measured by ELISA was linearly proportional to the number of immunolabeled cells between 6 and 34 days in culture; the developmental time courses of 2',3'-cyclic nucleotide 3'-phosphohydrolase (CNP) and myelin basic protein (MBP) expression determined by the two methods were very similar. Finally, cell suspensions were seeded at increasing dilution to determine the number of cells required to generate cultures that tested positive for oligodendrocytes by ELISA. As few as 9,000 cells were sufficient, predicting a minimum of 8,000 oligoprogenitors per 20-21 day fetal rat brain. The application of direct microculture ELISA for studying oligodendrocyte population size and myelinogenesis is discussed.

  11. Development and validation of the AmpFℓSTR® Identifiler® Direct PCR Amplification Kit: a multiplex assay for the direct amplification of single-source samples.

    Science.gov (United States)

    Wang, Dennis Y; Chang, Chien-Wei; Lagacé, Robert E; Oldroyd, Nicola J; Hennessy, Lori K

    2011-07-01

    The AmpFℓSTR(®) Identifiler(®) Direct PCR Amplification Kit is a new short tandem repeat multiplex assay optimized to allow the direct amplification of single-source blood and buccal samples on FTA(®) card without the need for sample purification and quantification. This multiplex assay has been validated according to the FBI/National Standards and SWGDAM guidelines. Validation results revealed that slight variations in primer concentration, master mix component concentration, and thermal cycling parameters did not affect the performance of the chemistry. The assay's sensitivity was demonstrated by amplifying known amounts of white blood cells spotted onto FTA(®) cards, and the assay's specificity was verified by establishing minimal cross-reactivity with nonhuman DNA. No effect on the age of the sample stored on the FTA(®) substrate was observed and full concordance was established in the population study. These findings of the validation study support the use of the Identifiler(®) Direct Kit for forensic standards and database samples genotyping. © 2011 American Academy of Forensic Sciences.

  12. Characterization of monoclonal antibodies against human thyrotropin and use in an immunoradiometric assay and immunohistochemistry

    International Nuclear Information System (INIS)

    Benkirane, M.; Bon, D.; Bellot, F.; Prince, P.; Delori, P.; Hassoun, J.; Carayon, P.

    1987-01-01

    Monoclonal antibodies were prepared against human thyrotropin. 13 different antibodies were characterized. Ten antibodies were of the IgG1 subclass. The affinities of the antibodies were in the range 10 9 -10 11 mol -1 .l. Four of them were specific for hTSH and did not react with hLH, hFSH, hCG or αhCG. Four reacted with these hormones and recognized the α subunit of hCG. One cross-reacted only with HFSH. The remaining four antibodies recognized the holo-hTSH only, and thus were designated as anti-conformational determinants. Monoclonal antibodies reacting with different antigenic determinants on the hTSH molecule defined seven clusters. Two of them were used to develop a simplified two-site sandwich radioimmunoassay in which one monoclonal antibody was immobilized on tubes (anti-βTSH) and another (anti-α) labelled with 125 I. This assay was highly specific and demonstrated a sensitivity level of 0.1 μIU/ml. Two monoclonal antibodies were used in immunohistochemistry and their quality and specificity was assessed in the detection of hTSH immunoreactivity in human pituitary biological sections. 20 refs.; 6 figs.; 2 tabs

  13. Increased specificity in human cardiac-myosin radioimmunoassay utilizing two monoclonal antibodies in a double sandwich assay

    International Nuclear Information System (INIS)

    Katus, H.A.; Hurrell, J.G.; Matsueda, G.R.; Ehrlich, P.; Zurawski, V.R. Jr.; Khaw, B.-A.; Haber, E.

    1982-01-01

    An immunoradiometric assay that simultaneously measured two different epitopes on the same molecule was devised to differential between cardiac- and skeletal-myosin light chains. Three monoclonal antibodies were examined that were 100% (lC5), 25% (2B9) and 17% (4F10) cross reactive, respectively, between the two antigens. One antibody of the pair to be studied was immobilized to cyanogen bromide-activated Sepharose 4B while the other was iodinated with 125 I using the lactoperoxidase method. The antigen was mixed with the immobilized antibody, the labeled antibody was added and the precipitate then washed and counted in a gamma counter. When both antibodies of the pair to be studied (immobilized and labeled) were the same (2B9), no radioactivity above background was bound to the precipitate, indicating that the second antibody could not bind to an already occupied epitope. When two different antibodies were employed, the specificity of the assay increased over that of a single antibody. The cross reactivity of a pair approximated the product of the cross reactivities of the individual antibodies. Thus, lC5 and 2B9 were 25% cross reactive together, lC5 and 4F10 17% cross reactive, and 2B9 and 4F10 4.3% cross reactive. (author)

  14. [A prospective study of adenosine triphosphate-tumor chemosensitivity assay directed chemotherapy in patients with recurrent ovarian cancer].

    Science.gov (United States)

    Gao, Yu-tao; Wu, Ling-ying; Zhang, Wei; Zhao, Dan; Li, Ning; Tian, Hai-mei; Wang, Xiao-bing; Li, Mo; Sun, Yang-chun; Li, Nan; Li, Xiao-guang

    2013-05-01

    To investigate the efficacy of adenosine triphosphate (ATP)-tumor chemosensitivity assay (TCA) directed chemotherapy in patients with recurrent epithelial ovarian cancer. From August 2010 to June 2012, recurrent epithelial ovarian cancer patients were prospectively enrollmented in Cancer Hospital, Peking Union Medical College,Chinese Academy of Medical Sciences.The entry criteria are as follows: (1) Histologically proven to be epithelial ovarian cancer. (2) Patients of recurrent ovarian cancer with bidimensionally measurable tumor, or ascitic or pleural fluid for testing. (3) Karnofsky performance status > 60. (4) A life expectancy of at least more than 6 months.According to patients desires, they were assigned into two groups: assay-directed therapy group and physician's-choice therapy group, patients' clinical and pathological characteristics, response rate to chemotherapy and progression-free survival (PFS) were compared between two groups. A total of 113 patients with recurrent epithelial ovarian cancer were prospectively enrollmented to assay-directed chemotherapy (n = 56) or physician's-choice chemotherapy (n = 57).There was no difference in median age,types of recurrence, surgical-pathological stage, pathological type, tumor grade, times of recurrence, residual disease at secondary cytoreductive surgery between assay-directed group and physician's-choice group. The overall response rate (ORR) and median PFS in the ATP-TCA group was 66% (37/56) and 7 months, while the ORR in the control group was 46% (26/57, P = 0.037), the median PFS was 4 months (P = 0.040). For platinum-resistant patients, the ORR between ATP-TCA directed chemotherapy 59% (16/27) and control group 25% (7/28) were significantly different (P = 0.010), and the median PFS between two groups were also significantly different (5 months and 2 months, respectively, P = 0.003). ATP-TCA directed chemotherapy could improve ORR and PFS in patients with recurrent epithelial ovarian cancer, especially

  15. Selection of matched pair of monoclonal antibodies for development of immunoradiometric assay (IRMA) : our experience with IRMA of TSH

    International Nuclear Information System (INIS)

    Kadwad, V.B.; Jyotsna, N.; Sivaprasad, N.

    1998-01-01

    Full text: In immunoradiometricassay (IRMA) two antibodies raised against two different epitopes of the same antigen are used, one bound to a solid phase (capture antibody) and the other labelled with 125 I (detector antibody). The development of any IRMA thus involves proper selection of the capture and detector antibody, preparation of solid phase, labelling of the antibody and assay optimization. Extensive studies have been carried out on these aspects in our laboratory with greater emphasis on the behavior of different pairs of antibodies as sandwich partners : monoclonal-monoclonal and monoclonal-polyclonal antibodies. The parameters studied include the ease of radio-iodination of different monoclonal antibodies, the effect of interchange of capture and detector antibody etc. Keeping TSH antibody as a model, two different monoclonal antibodies, a polyclonal antibody and a tracer from a commercial TSH IRMA kit were used in this study. Based on our studies an assay procedure for in-house IRMA of TSH has been developed with a sensitivity of 0.1 μIU/ml and validated

  16. Development of sensitive direct and indirect enzyme-linked immunosorbent assays (ELISAs) for monitoring bisphenol-A in canned foods and beverages.

    Science.gov (United States)

    Lu, Yang; Peterson, Joshua Richard; Gooding, John Justin; Lee, Nanju Alice

    2012-06-01

    Enzyme-linked immunosorbent assays (ELISAs) are investigated in this work for the detection of bisphenol-A (BPA), a plastic monomer and a critical contaminant in food and environment. A series of polyclonal antibodies generated in vivo using BPA-butyrate-protein conjugate and BPA-valerate-protein conjugate were evaluated on direct and indirect competitive assay formats with five competing haptens (BPA-butyrate, BPA-valerate, BPA-crotonate, BPA-acetate, and BPA-2-valerate). Two indirect ELISAs and one direct ELISA exhibiting high sensitivity and specificity for BPA were developed. The 50 % inhibition of antibody binding (IC(50)) values were 0.78 ± 0.01-1.20 ± 0.26 μg L(-1), and the limits of detection as measured by the IC(20) values were 0.10 ± 0.03-0.20 ± 0.04 μg L(-1). The assays were highly specific to BPA, only displaying low cross-reactivity (3-8 % for the indirect assays and 26 % for the direct assay) for 4-cumylphenol (4-CP), at pH 7.2. The degree of cross-reaction of 4-CP was influenced by the antibody/hapten conjugate combination, assay conditions, and the assay format. The assays were optimized for the analysis of BPA in canned vegetables, bottled water and carbonated drinks. The limits of quantification for these three evaluated sample types, based on the spike and recovery data, were 0.5, 2.5, and 100 μg L(-1), respectively.

  17. Development of a direct PCR assay to detect Taenia multiceps eggs isolated from dog feces.

    Science.gov (United States)

    Wang, Ning; Wang, Yu; Ye, Qinghua; Yang, Yingdong; Wan, Jie; Guo, Cheng; Zhan, Jiafei; Gu, Xiaobin; Lai, Weimin; Xie, Yue; Peng, Xuerong; Yang, Guangyou

    2018-02-15

    Taenia multiceps is a tapeworm that leads to the death of livestock, resulting in major economic losses worldwide. The adult stage of this parasite invades the small intestine of dogs and other canids. In the present study, we developed a direct PCR assay to detect T. multiceps eggs isolated from dog feces to help curb further outbreaks. The genomic DNA was rapidly released using a lysis buffer and the PCR reaction was developed to amplify a 433-bp fragment of the T. multiceps mitochondrial gene encoding NADH dehydrogenase subunit 5 (nad5) from eggs isolated from dog feces. The procedure could be completed within 3 h, including flotation. The sensitivity of the assay was determined by detecting DNA from defined numbers of eggs, and the specificity was determined by detecting DNA from other intestinal tapeworm and roundworm species that commonly infect dogs. In addition, 14 taeniid-positive fecal samples determined by the flotation technique were collected and further evaluated by the regular PCR and our direct PCR. The results showed that the direct PCR developed herein was sensitive enough to detect the DNA from as few as 10 T. multiceps eggs and that no cross-reactions with other tapeworm and roundworm were observed, suggesting its high sensitivity and specificity for T. multiceps detection. Moreover, 14 taeniid-positive samples were screened by the regular PCR and direct PCR, with detection rates of 78.6% and 85.7%, respectively. In conclusion, the direct PCR assay developed in the present study has high sensitivity and specificity to identify T. multiceps eggs isolated from dog feces and therefore could represent an invaluable tool to identify T. multiceps outbreaks and would contribute to future clinical applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Ultrasensitive human thyrotropin (h TSH) immunoradiometric assay (IRMA) set up, through identification and minimization of non specific bindings

    International Nuclear Information System (INIS)

    Peroni, C.N.

    1994-01-01

    An IRMA of h TSH, based on magnetic solid phase separation, was studied especially for what concerns its non specific bindings. These were identified as a product of the interaction between an altered form of radioiodinated anti-h TSH monoclonal antibody ( 125 I-m AB) and the uncoupled magnetizable cellulose particle (matrix). Apparently this form of 125 I-m AB is a type of aggregate that can be partly resolved from the main peak on Sephadex G-200 and further minimized via a single pre-incubation with the same matrix. Solid phase saturation with milk proteins, tracer storage at 4 0 C and serum addition during incubation were also found particularly effective is preventing its formation. These findings were used in order to reproducibly decrease non specific bindings to values 60 /B O ) up to values of 300-500. This way we obtained h TSH radio assays with functional sensitivities of about 0.05 m IU/L and analytical sensitivities of the order of 0.02 m IU/L, which classify them at least as among the best second generation assays and that are excellent indeed for magnetic IRMA s. A more optimistic sensitivity calculation, based on Rodbard's definition, provided values down to 0.008 m IU/L. Such sensitivities, moreover, were obtained in a very reproducible way and all over the useful tracer life. (author). 83 refs, 13 figs, 25 tabs

  19. Prospective assessment of early fetal loss using an immunoenzymometric screening assay for detection of urinary human chorionic gonadotropin.

    Science.gov (United States)

    Taylor, C A; Overstreet, J W; Samuels, S J; Boyers, S P; Canfield, R E; O'Connor, J F; Hanson, F W; Lasley, B L

    1992-06-01

    To develop an economical, nonradiometric immunoenzymometric assay (IEMA) for the detection of urinary human chorionic gonadotropin (hCG) in studies of early fetal loss. To be effective, the IEMA must have a sensitivity equal to the standard immunoradiometric assay (IRMA) and sufficient specificity to eliminate the need for screening most nonconceptive cycles with the expensive and labor-intensive IRMA. Two different assays were used to measure hCG in daily early morning urine samples from potential conceptive cycles. Women undergoing donor artificial insemination (AI) were evaluated in a prospective study. Ninety-two women volunteers were selected on the basis of apparent normal reproductive health. Artificial insemination with nonfrozen donor semen was performed by cervical cup twice each menstrual cycle at 48-hour intervals, and daily urine samples were self-collected throughout the menstrual cycle. An IEMA was developed to detect urinary hCG using the same antibodies as in the standard IRMA; a study was designed to determine whether this nonradiometric assay could successfully detect the early fetal loss that was detected by the IRMA. Of 224 menstrual cycles analyzed by both assays, a total of six early fetal losses were detected by the IRMA. When the tentative screening rule was set to allow all six of these losses and 95% of future losses to be detected by the IEMA, an additional 34 false-positive results were detected by the IEMA. The specificity of the IEMA with this rule was calculated to be 84%. An IEMA based on the same antibodies used for the standard IRMA can serve as an efficient screening assay for the detection of early fetal loss. When the IEMA is used in this manner, nearly 80% of screened menstrual cycles can be eliminated without further testing by the IRMA.

  20. Concordance between results of somatostatin receptor scintigraphy with 111In-DOTA-DPhe 1-Tyr 3-octreotide and chromogranin A assay in patients with neuroendocrine tumours.

    Science.gov (United States)

    Rodrigues, Margarida; Gabriel, Michael; Heute, Dirk; Putzer, Daniel; Griesmacher, Andrea; Virgolini, Irene

    2008-10-01

    Somatostatin receptor scintigraphy (SRS) and chromogranin A (CgA) assay have successfully been implemented in the clinical work-up and management of neuroendocrine tumour (NET) patients. However, there is still a lack of studies comparing results in these patients. Our aim was to compare directly in NET patients SRS and CgA assay results with special regard to tumour features such as grade of malignancy, primary origin, disease extent and function. One hundred twenty consecutive patients with histological confirmed NETs were investigated with (111)In-DOTA-DPhe(1)-Tyr(3)-octreotide ((111)In-DOTA-TOC) SRS and CgA immunoradiometric assay. Tumours were classified by cell characteristics [well-differentiated NETs, well-differentiated neuroendocrine carcinomas, poorly differentiated neuroendocrine carcinomas (PDNECs)], primary origin (foregut, midgut, hindgut, undetermined), disease extent (limited disease, metastases, primary tumour and metastases) and functionality (secretory, nonsecretory). SRS was positive in 107 (89%) patients; CgA levels were increased in 95 (79%) patients. Overall, concordance between SRS and CgA results was found in 84 patients. Positive SRS but normal CgA level were found in 24 patients, with higher prevalence (p<0.05) in patients with nonsecretory tumours. Conversely, negative SRS but CgA level increased were seen in 12 patients, with higher proportion (p<0.05) in patients with PDNECs and tumours of hindgut origin. Overall, (111)In-DOTA-TOC SRS proved to be more sensitive than CgA in NETs patients. Tumour differentiation, disease extent and presence of liver metastases impact both SRS and CgA results, whereas nonsecretory activity is a negative predictor of only CgA increase. PDNECs and hindgut origin of tumours predispose to discrepancies with negative SRS but increased CgA levels.

  1. Separation of radioimmunoassay in magnetic phase with particles prepared at the IPEN and its comparison with conventional methodologies

    International Nuclear Information System (INIS)

    Araujo, E.A. de.

    1991-01-01

    In the present work two main objectives were chosen. The first was the preparation for the execution of the magnetic phase separation technique, useful for the radioimmunoassay as well as for the most modern and most efficient immunoradiometric assay. The second objective, of a theoretical-practical kind and directly linked to the first, was the realization of a study about the precision of the technique with synthesized products compared with imported products and with two liquid phase separation techniques: the second antibody and polyethyleneglycol (PEG). This analysis was performed with the help of precision profiles built according to R.P.Ekins' recommendations. (author)

  2. Immunochemical cross-reactivity between albumin and solid-phase adsorbed histamine

    DEFF Research Database (Denmark)

    Poulsen, L K; Nolte, H; Søndergaard, I

    1990-01-01

    For production of an antibody against histamine, this was coupled to human serum albumin (HSA) and used for immunization of rabbits. To test the antiserum, an immunoradiometric assay was developed comprising solid-phase bound histamine, antisera and radiolabelled protein A. Titration and inhibition...

  3. Longitudinal study of serum placental GH in 455 normal pregnancies

    DEFF Research Database (Denmark)

    Chellakooty, Marla; Skibsted, Lillian; Skouby, Sven O

    2002-01-01

    women with normal singleton pregnancies at approximately 19 and 28 wk gestation. Serum placental GH concentrations were measured by a highly specific immunoradiometric assay, and fetal size was measured by ultrasound. Data on birth weight, gender, prepregnancy body mass index (BMI), parity, and smoking...

  4. Concordance between results of somatostatin receptor scintigraphy with {sup 111}In-DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide and chromogranin A assay in patients with neuroendocrine tumours

    Energy Technology Data Exchange (ETDEWEB)

    Rodrigues, Margarida [Medical University of Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria); Hietzing Hospital, Institute of Nuclear Medicine, Vienna (Austria); Gabriel, Michael; Heute, Dirk; Putzer, Daniel; Virgolini, Irene [Medical University of Innsbruck, Department of Nuclear Medicine, Innsbruck (Austria); Griesmacher, Andrea [Medical University of Innsbruck, Central Institute of Medical and Chemical Laboratory Diagnostics, Innsbruck (Austria)

    2008-10-15

    Somatostatin receptor scintigraphy (SRS) and chromogranin A (CgA) assay have successfully been implemented in the clinical work-up and management of neuroendocrine tumour (NET) patients. However, there is still a lack of studies comparing results in these patients. Our aim was to compare directly in NET patients SRS and CgA assay results with special regard to tumour features such as grade of malignancy, primary origin, disease extent and function. One hundred twenty consecutive patients with histological confirmed NETs were investigated with {sup 111}In-DOTA-DPhe{sup 1}-Tyr{sup 3}-octreotide ({sup 111}In-DOTA-TOC) SRS and CgA immunoradiometric assay. Tumours were classified by cell characteristics [well-differentiated NETs, well-differentiated neuroendocrine carcinomas, poorly differentiated neuroendocrine carcinomas (PDNECs)], primary origin (foregut, midgut, hindgut, undetermined), disease extent (limited disease, metastases, primary tumour and metastases) and functionality (secretory, nonsecretory). SRS was positive in 107 (89%) patients; CgA levels were increased in 95 (79%) patients. Overall, concordance between SRS and CgA results was found in 84 patients. Positive SRS but normal CgA level were found in 24 patients, with higher prevalence (p<0.05) in patients with nonsecretory tumours. Conversely, negative SRS but CgA level increased were seen in 12 patients, with higher proportion (p < 0.05) in patients with PDNECs and tumours of hindgut origin. Overall, {sup 111}In-DOTA-TOC SRS proved to be more sensitive than CgA in NETs patients. Tumour differentiation, disease extent and presence of liver metastases impact both SRS and CgA results, whereas nonsecretory activity is a negative predictor of only CgA increase. PDNECs and hindgut origin of tumours predispose to discrepancies with negative SRS but increased CgA levels. (orig.)

  5. Pulsatile thyrotropin secretion in patients with Cushing's syndrome

    NARCIS (Netherlands)

    Adriaanse, R.; Brabant, G.; Endert, E.; Wiersinga, W. M.

    1994-01-01

    Pulsatile and circadian thyrotropin (TSH) secretion were studied in 16 healthy controls and in three patients with Cushing's syndrome who were studied twice (before and after treatment). Blood was sampled every 10 minutes over 24 hours for TSH (immunoradiometric assay [IRMA]). Mean 24-hour TSH in

  6. Tumour associated antigen CA-50, CA-242 immunoradiometric assay (IRMA) in genitourinary malignancy and gastrointestinal carcinoma early diagnosis

    International Nuclear Information System (INIS)

    Chen Zhizhou.

    1992-04-01

    Tumour markers CA-50 and CA-242 were measured by immunometric assay (IRMA) to investigate their usefulness in the diagnosis of cancer of the pancreas, biliary tract, liver, breast, lung, gastrointestinal and genitourinary systems. The cutoff points, derived from studies on normal subjects and those with proven benign disease, were 20 u/ml and 12 u/ml for CA-50 and CA-242 respectively. Both markers were found to be generally useful with significant differences between malignant and non malignant disease. The highest positive rates, were found in cancers of the pancreas and gall bladder. The overall rate of false positives was low. It is concluded that measurements of CA-50 and CA-242 are useful in the detection of malignancy, particularly of the pancreas and biliary tract. 2 figs, 2 tabs

  7. A novel rapid direct haemagglutination-inhibition assay for measurements of humoral immune response against non-haemagglutinating Fowlpox virus strains in vaccinated chickens.

    Science.gov (United States)

    Wambura, Philemon N; Mzula, Alexanda

    2017-10-01

    Fowlpox (FP) is a serious disease in chickens caused by Fowlpox virus (FPV). One method currently used to control FPV is vaccination followed by confirmation that antibody titres are protective using the indirect haemagglutination assay (IHA). The direct haemagglutination inhibition (HI) assay is not done because most FPV strains do not agglutinate chicken red blood cells (RBCs). A novel FPV strain TPV-1 which agglutinates chicken RBCs was discovered recently and enabled a direct HI assay to be conducted using homologous sera. This study is therefore aimed at assessing the direct HI assay using a recently discovered novel haemagglutinating FPV strain TPV-1 in chickens vaccinated with a commercial vaccine containing a non-haemagglutinating FPV.Chicks vaccinated with FPV at 1 day-old had antibody geometric mean titres (GMT) of log 2 3.7 at 7 days after vaccination and log 2 8.0 at 28 days after vaccination when tested in the direct HI. Chickens vaccinated at 6 weeks-old had antibody geometric mean titres (GMT) of log 2 5.0 at 7 days after vaccination and log 2 8.4 at 28 days after vaccination when tested in the direct HI. The GMT recorded 28 days after vaccination was slightly higher in chickens vaccinated at 6-week-old than in chicks vaccinated at one-day-old. However, this difference was not significant (P > 0.05). All vaccinated chickens showed "takes". No antibody response to FPV and "takes" were detected in unvaccinated chickens (GMT 0.05). These findings indicate that a simple and rapid direct HI assay using the FPV TPV-1 strain as antigen may be used to measure antibody levels in chickens vaccinated with non-haemagglutinating strains of FPV, and that the titres are comparable to those obtained by indirect IHA.

  8. A coupled photometric assay for characterization of S-adenosyl-l-homocysteine hydrolases in the physiological hydrolytic direction.

    Science.gov (United States)

    Kailing, Lyn L; Bertinetti, Daniela; Herberg, Friedrich W; Pavlidis, Ioannis V

    2017-10-25

    S-Adenosyl-l-homocysteine hydrolases (SAHases) are important metabolic enzymes and their dysregulation is associated with some severe diseases. In vivo they catalyze the hydrolysis of S-adenosyl-l-homocysteine (SAH), the by-product of methylation reactions in various organisms. SAH is a potent inhibitor of methyltransferases, thus its removal from the equilibrium is an important requirement for methylation reactions. SAH hydrolysis is also the first step in the cellular regeneration process of the methyl donor S-adenosyl-l-methionine (SAM). However, in vitro the equilibrium lies towards the synthetic direction. To enable characterization of SAHases in the physiologically relevant direction, we have developed a coupled photometric assay that shifts the equilibrium towards hydrolysis by removing the product adenosine, using a high affinity adenosine kinase (AK). This converts adenosine to AMP and thereby forms equimolar amounts of ADP, which is phosphorylated by a pyruvate kinase (PK), in turn releasing pyruvate. The readout of the assay is the consumption of NADH during the lactate dehydrogenase (LDH) catalyzed reduction of pyruvate to lactic acid. The applicability of the assay is showcased for the determination of the kinetic constants of an SAHase from Bradyrhizobium elkanii (K M,SAH 41±5μM, v max,SAH 25±1μM/min with 0.13mg/mL enzyme). This assay is a valuable tool for in vitro characterization of SAHases with biotechnological potential, and for monitoring SAHase activity in diagnostics. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Estimates of DNA damage by the comet assay in the direct-developing frog Eleutherodactylus johnstonei (Anura, Eleutherodactylidae

    Directory of Open Access Journals (Sweden)

    Laura Carolina Valencia

    2011-01-01

    Full Text Available The aim of this study was to use the Comet assay to assess genetic damage in the direct-developing frog Eleutherodactylus johnstonei. A DNA diffusion assay was used to evaluate the effectiveness of alkaline, enzymatic and alkaline/enzymatic treatments for lysing E. johnstonei blood cells and to determine the amount of DNA strand breakage associated with apoptosis and necrosis. Cell sensitivity to the mutagens bleomycin (BLM and 4-nitroquinoline-1-oxide (4NQO was also assessed using the Comet assay, as was the assay reproducibility. Alkaline treatment did not lyse the cytoplasmic and nuclear membranes of E. johnstonei blood cells, whereas enzymatic digestion with proteinase K (40 !g/mL yielded naked nuclei. The contribution of apoptosis and necrosis (assessed by the DNA diffusion assay to DNA damage was estimated to range from 0% to 8%. BLM and 4NQO induced DNA damage in E. johnstonei blood cells at different concentrations and exposure times. Dose-effect curves with both mutagens were highly reproducible and showed consistently low coefficients of variation (CV < 10%. The results are discussed with regard to the potential use of the modified Comet assay for assessing the exposure of E. johnstonei to herbicides in ecotoxicological studies.

  10. Estimates of DNA damage by the comet assay in the direct-developing frog Eleutherodactylus johnstonei (Anura, Eleutherodactylidae).

    Science.gov (United States)

    Valencia, Laura Carolina; García, Adriana; Ramírez-Pinilla, Martha Patricia; Fuentes, Jorge Luis

    2011-10-01

    The aim of this study was to use the Comet assay to assess genetic damage in the direct-developing frog Eleutherodactylus johnstonei. A DNA diffusion assay was used to evaluate the effectiveness of alkaline, enzymatic and alkaline/enzymatic treatments for lysing E. johnstonei blood cells and to determine the amount of DNA strand breakage associated with apoptosis and necrosis. Cell sensitivity to the mutagens bleomycin (BLM) and 4-nitro-quinoline-1-oxide (4NQO) was also assessed using the Comet assay, as was the assay reproducibility. Alkaline treatment did not lyse the cytoplasmic and nuclear membranes of E. johnstonei blood cells, whereas enzymatic digestion with proteinase K (40 μg/mL) yielded naked nuclei. The contribution of apoptosis and necrosis (assessed by the DNA diffusion assay) to DNA damage was estimated to range from 0% to 8%. BLM and 4NQO induced DNA damage in E. johnstonei blood cells at different concentrations and exposure times. Dose-effect curves with both mutagens were highly reproducible and showed consistently low coefficients of variation (CV ≤ 10%). The results are discussed with regard to the potential use of the modified Comet assay for assessing the exposure of E. johnstonei to herbicides in ecotoxicological studies.

  11. Comparison of Friedewald Formula and Modified Friedewald Formula with Direct Homogeneous Assay for Low Density Lipoprotein Cholesterol Estimation

    International Nuclear Information System (INIS)

    Anwar, M.; Khan, D. A.; Khan, F. A.

    2014-01-01

    Objective: To compare the Friedewald and modified Friedewald formulae with direct homogeneous assay for serum lowdensity lipoprotein cholesterol (LDL-C) levels estimation. Study Design: Cross-sectional study. Place and Duration of Study: Armed Forces Institute of Pathology, Rawalpindi, from June to December 2011. Methodology: Healthy subjects of either gender, from Rawalpindi, aged 18-75 years were included by consecutive sampling. Patients with diabetes mellitus, chronic liver disease, chronic kidney disease, those taking lipid lowering drugs and samples with triglyceride (TG) > 4.52 mmol/l were excluded from the study. Total cholesterol, high-density lipoprotein cholesterol, TG and LDL-C were measured on Hitachi 912 chemistry analyzer (Roche). LDL-C levels were also calculated by Friedewald formula (FF) and Vujovic modified formula (VMF). Paired sample t-test and scatter plots were used for statistical analysis. Results: Although both calculated methods showed good correlation with direct assay (r > 0.93) in 300 subjects, but the difference was statistically significant. The ffLDL-C were 0.12 +- 31 mmol/l (p < 0.001) lower and vmfLDL-C were 0.11 +- 26 mmol/l (p < 0.001) higher than dLDL-C. The difference was not significant between ffLDL-C and dLDL-C at TG levels < 1.70 mmol/l (p = 0.58) and between vmfLDL-C and dLDL-C at TG levels 2.26 - 4.52 mmol/l (p = 0.38). At all other TG levels, the difference between LDL-C calculated by both formulas and dLDL-C was statistically significant (p < 0.001). As compared to direct assay, 11% and 14% subjects were classified in wrong National Cholesterol Education Programm cardiac risk categories by FF and VMF respectively. Conclusion: LDL-C should be measured by direct homogeneous assay in routine clinical laboratories, as the calculated methods did not have a uniform performance for LDL-C estimation at different TG levels. (author)

  12. Radiolabelling for immunoassay

    International Nuclear Information System (INIS)

    Chapman, R.S.

    1998-01-01

    Since the early 1960s labelled compounds employed in immunoassay techniques, both radioimmunoassay and immunoradiometric assay, have involved radioisotopes typically 3 H (tritium) and 125 Iodine. With the advent of increasingly stringent governmental regulations regarding usage and disposal of radioisotopes and the impetus of research towards improved immunoassay sensitivity following the discovery of monoclonal antibodies and their application to excess reagent immunometric assay methodology, radioisotopic labels are gradually being replaced by non-isotopic labels: enzyme, fluorescence and chemiluminescence

  13. Detecting paraprotein interference on a direct bilirubin assay by reviewing the photometric reaction data.

    Science.gov (United States)

    García-González, Elena; Aramendía, Maite; González-Tarancón, Ricardo; Romero-Sánchez, Naiara; Rello, Luis

    2017-07-26

    The direct bilirubin (D-Bil) assay on the AU Beckman Coulter instrumentation can be interfered by paraproteins, which may result in spurious D-Bil results. In a previous work, we took advantage of this fact to detect this interference, thus helping with the identification of patients with unsuspected monoclonal gammopathies. In this work, we investigate the possibility to detect interference based on the review of the photometric reactions, regardless of the D-Bil result. The D-Bil assay was carried out in a set of 2164 samples. It included a group of 164 samples with paraproteins (67 of which caused interference on the assay), as well as different groups of samples for which high absorbance background readings could also be expected (i.e. hemolyzed, lipemic, or icteric samples). Photometric reaction data were reviewed and receiver operating characteristics (ROC) curves were used to establish a cut-off for absorbance that best discriminates interference. The best cut-off was 0.0100 for the absorbance at the first photometric point of the complementary wavelength in the blank cuvette. Once the optimal cut-off for probable interference was selected, all samples analyzed in our laboratory that provided absorbance values above this cut-off were further investigated to try to discover paraproteins. During a period of 6 months, we detected 44 samples containing paraproteins, five of which belonged to patients with non-diagnosed monoclonal gammopathies. Review of the photometric reaction data permits the systematic detection of paraprotein interference on the D-Bil AU assay, even for samples for which reasonable results are obtained.

  14. Reproductive hormones disorders of Sudanese females using immunoradiometric assay (IRMA)

    International Nuclear Information System (INIS)

    Ali, N. I.; Almahi, W. A. A.; Abdalla, O. M.; Bafarag, S. M. I.; Abdelgadir, O. M.; Eltayeb, M. A. H.; Hassan, A. M. E.; Hassan, A. M. E.

    2004-12-01

    In this study fertility hormones were measured for 587 infertile Sudanese female referred from gynecological clinics. The ages of these female ranges from 16-50 years divided into seven groups. Eighty seven percent of them are in the age range between 21 and 40 year which correlate with the female's fertile period and 5.6% of them under 20 years. Sensitive (IRMA) method was used for measuring the hormone concentration. The objective of this study was to found out the percentage of hormonal disorders and its relation to the age in infertile Sudanese females. The age group (21-25) was the most affected group by the Poly Cystic Ovary Syndrome (PCOS) and represented 5.1% of the total number of patients. The least group was the age group (41-45) with a percentage of 0.4. The LH and the FSH in the age group of (31-35) was found to be higher than the other groups and represented 11.4% and 7.8% from the total number of patients respectively. The least percent of high level of LH and FSH was found to be in the most fertile age group (15-20) and it was 1.7% and 1.0% from the total number of studied patient, respectively. Those who were in the age range (26-30) with hyperprolactinaemia represented 10.4% of patients, while those with age rang (46-50) with hyperprolactinaemia represented the lowest percentage (1.2%). The percentage of patients having high LH and high FSH was 44.5% and 29.1% respectively, while the hyperprolactinaemia among the infertile Sudanese female was found to 38.2%.(Author)

  15. Rapid and direct spectrophotometric method for kinetics studies and routine assay of peroxidase based on aniline diazo substrates.

    Science.gov (United States)

    Mirazizi, Fatemeh; Bahrami, Azita; Haghbeen, Kamahldin; Shahbani Zahiri, Hossein; Bakavoli, Mehdi; Legge, Raymond L

    2016-12-01

    Peroxidases are ubiquitous enzymes that play an important role in living organisms. Current spectrophotometrically based peroxidase assay methods are based on the production of chromophoric substances at the end of the enzymatic reaction. The ambiguity regarding the formation and identity of the final chromophoric product and its possible reactions with other molecules have raised concerns about the accuracy of these methods. This can be of serious concern in inhibition studies. A novel spectrophotometric assay for peroxidase, based on direct measurement of a soluble aniline diazo substrate, is introduced. In addition to the routine assays, this method can be used in comprehensive kinetics studies. 4-[(4-Sulfophenyl)azo]aniline (λmax = 390 nm, ɛ = 32 880 M(-1) cm(-1) at pH 4.5 to 9) was introduced for routine assay of peroxidase. This compound is commercially available and is indexed as a food dye. Using this method, a detection limit of 0.05 nmol mL(-1) was achieved for peroxidase.

  16. Evaluation of a Direct Immunofluorescent Assay and/or Conjunctival Cytology for Detection of Canine Distemper Virus Antigen.

    Science.gov (United States)

    Athanasiou, Labrini V; Kantere, Maria C; Kyriakis, Constantinos S; Pardali, Dimitra; Adamama Moraitou, Katerina; Polizopoulou, Zoe S

    2018-04-01

    Canine distemper is a common and potentially lethal multisystemic disease caused by the Canine distemper virus (CDV). We evaluated the diagnostic performance of direct immunofluorescent assay (FA) and cytology to detect CDV antigen in conjunctival cells compared with an established polymerase chain reaction (PCR) detection assay used as a gold standard for CDV diagnosis. Samples were collected from 57 young dogs presenting with central nervous system signs compatible with distemper disease. Exfoliative epithelial cells were collected from the right and left conjunctiva of each animal using nylon-bristled cytobrushes for cytology and cotton swabs for FA and PCR. For the direct FA, samples were stained with anti-CDV polyclonal antiserum conjugated to fluorescein isothiocyanate and imaged using a fluorescent microscope. Out of 57 dogs tested, 19 were PCR positive (15 positive in direct FA and 4 positive in cytology, including one that was negative by PCR), whereas 37 dogs were negative in all methods. A good agreement was observed between the FA and PCR, with a κ-value of 0.833 (95% CI: 0.678-0.989). Meanwhile, there was poor agreement between cytology and PCR (κ-value of 0.164; 95% CI: -0.045 to 0.373) and a fair agreement between FA and cytology (κ-value of 0.231; 95% CI: -0.026 to 0.487). Our results indicated a poor performance of cytology for the detection of CDV antigen. In contrast, FA is a 100% specific and an adequately sensitive assay (sensitivity: 78.95%, negative likelihood ratio: 0.21, 95% CI: 0.09-0.50) for antemortem diagnosis of canine distemper.

  17. Acetone enhances the direct analysis of total condensed tannins in plant tissues by the butanol-HCl-iron assay

    Science.gov (United States)

    The butanol-HCl spectrophotometric assay is widely used to quantify extractable and insoluble forms of condensed tannin (CT, syn. proanthocyanidin) in foods, feeds, and foliage of herbaceous and woody plants. However, this method underestimates total CT content when applied directly to plant materia...

  18. A three-layer immunoradiometric assay for antibodies in different immunoglobulin classes and its application to the detection of chicken thyroglobulin autoantibodies and of antibodies to sheep erythrocytes

    International Nuclear Information System (INIS)

    Carvalho, L.C.P. de; Roitt, I.M.; Wick, G.

    1980-01-01

    A versatile solid-phase assay for detection of antibodies in different immunoglobulin classes is described. The assay has been applied to: (1) the detection of IgG and IgM antithyroglobulin autoantibodies in chickens with spontaneous autoimmune thyroiditis, and (2) the detection of anti-sheep cell antibodies in normal chickens. Thyroglobulin-coated plastic tubes or formaldehyde-fixed sheep erythrocytes were used as the solid phase. Antisera were added in succession to the solid-phase antigen so as to form 3 antibody layers: (1) chicken antibody against the solid-phase antigen; (2) heavy-chain-specific rabbit anti-chicken immunoglobulin; and (3) 125 I-labelled goat anti-rabbit immunoglobulin. The assay is suitable for routine determinations on large numbers of samples; its sensitivity enables small volumes of serum to be tested and allows considerable economy in the use of valuable class-specific antisera. The radiolabelled reagent can be readily applied to other assays employing rabbit antisera. (Auth.)

  19. Clinical utility of a two-site immunoradiometric assay for creatine kinase-MB in the detection of perioperative myocardial infarction

    International Nuclear Information System (INIS)

    DePuey, E.G.; Aessopos, A.; Monroe, L.R.; Hall, R.J.; Thompson, W.L.; Sonnemaker, R.E.; Burdine, J.A.

    1983-01-01

    In 144 patients, creatine kinase MB was measured serially at 0, 8, 16, 24, 48 and 72 h using a two-site immunoradionmetric assay (IRMA). Cardiac enzymes were also measured, including SGOT, LDH, total CPK, and CK-MB by electrophoresis. The presence of perioperative myocardial infarction (poMI) was established in 24 patients by the appearance of new electrocardiographic Q waves and/or new wall motion abnormalities detected by radionuclide ventriculography. In patients without poMI, CK-MB (IRMA) was elevated at 0 to 8 h but decreased by 16 h. In patients with poMI, peak values occurred at 16 to 24 h. Using a threshold value of 8.5 EU/I, patients with poMI could be distinguished from those without with 97% accuracy (sensitivity = 88%, specificity = 99%). We conclude that the CK-MB (IRMA) can serve as a valuable postoperative screening tet for poMI

  20. Comparison of Simplexa universal direct PCR with cytotoxicity assay for diagnosis of Clostridium difficile infection: performance, cost, and correlation with disease.

    Science.gov (United States)

    Landry, Marie L; Ferguson, David; Topal, Jeffrey

    2014-01-01

    Simplexa Clostridium difficile universal direct PCR, a real-time PCR assay for the detection of the C. difficile toxin B (tcdB) gene using the 3M integrated cycler, was compared with a two-step algorithm which includes the C. Diff Chek-60 glutamate dehydrogenase (GDH) antigen assay followed by cytotoxin neutralization. Three hundred forty-two liquid or semisolid stools submitted for diagnostic C. difficile testing, 171 GDH antigen positive and 171 GDH antigen negative, were selected for the study. All samples were tested by the C. Diff Chek-60 GDH antigen assay, cytotoxin neutralization, and Simplexa direct PCR. Of 171 GDH-positive samples, 4 were excluded (from patients on therapy or from whom duplicate samples were obtained) and 88 were determined to be true positives for toxigenic C. difficile. Of the 88, 67 (76.1%) were positive by the two-step method and 86 (97.7%) were positive by PCR. Seventy-nine were positive by the GDH antigen assay only. Of 171 GDH antigen-negative samples, none were positive by PCR. One antigen-negative sample positive by the cytotoxin assay only was deemed a false positive based on chart review. Simplexa C. difficile universal direct PCR was significantly more sensitive for detecting toxigenic C. difficile bacteria than cytotoxin neutralization (P = 0.0002). However, most PCR-positive/cytotoxin-negative patients did not have clear C. difficile disease. The estimated cost avoidance provided by a more rapid molecular diagnosis was outweighed by the cost of isolating and treating PCR-positive/cytotoxin-negative patients. The costs, clinical consequences, and impact on nosocomial transmission of treating and/or isolating patients positive for toxigenic C. difficile by PCR but negative for in vivo toxin production merit further study.

  1. Serum ferritin

    International Nuclear Information System (INIS)

    Rochna Viola, E.M.; Diaz de Domingo, N.B.; Lazarowski, A.

    1981-01-01

    Serum ferritin (SF) concentration as determined by the immunoradiometric method allows the direct measurement of a fraction of the body ferritin pool. In normal subjects, SF is an excellent index of body iron stores. In certain conditions associated with increased ferritin synthesis (such as liver disease, inflammation, malignancy, chronic disorders, ineffective erythropoiesis, or during ferrotherapy), SF may not accurately reflect body iron stores. In hyposideremic anemias SF concentration permits to differentiate those due to iron deficiency from those due to chronic disorders. With a good assay quality, subnormal SF levels are incontrovertible in the diagnosis of iron deficiency. SF determination has been investigated as possible tumor marker. When performed in combination with the alpha-fetoprotein assay, SF enhances the specificity of serodiagnosis of hepatoma. SF results must be interpreted bearing in mind the possible participation of circumstances that i) modify the body iron stores and ii) lead to increased ferritin synthesis. (author) [es

  2. Comparative efficacy of antigen and antibody detection tests for human trichinellosis

    International Nuclear Information System (INIS)

    Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.; Murrell, K.D.

    1989-01-01

    Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory products of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation

  3. Pistachio (Pistacia vera L.) Detection and Quantification Using a Murine Monoclonal Antibody-Based Direct Sandwich Enzyme-Linked Immunosorbent Assay.

    Science.gov (United States)

    Liu, Changqi; Chhabra, Guneet S; Sathe, Shridhar K

    2015-10-21

    A commercially available direct sandwich enzyme-linked immunosorbent assay (ELISA) (BioFront Technologies, Tallahassee, FL, USA) using murine anti-pistachio monoclonal antibodies (mAbs) as capture and detection antibodies was evaluated. The assay was sensitive (limit of detection = 0.09 ± 0.02 ppm full fat pistachio, linear detection range = 0.5-36 ppm, 50% maximum signal concentration = 7.9 ± 0.7 ppm), reproducible (intra- and inter-assay variability pistachio seeds subjected to autoclaving (121 °C, 15 psi, 15, 30 min), blanching (100 °C, 5, 10 min), frying (191 °C, 1 min), microwaving (500, 1000 W, 3 min), and dry roasting (140 °C, 30 min; 168 °C, 12 min). No cross-reactivity was observed in 156 food matrices, each tested at 100,000 ppm, suggesting the ELISA to be pistachio specific. The pistachio recovery ranges for spiked (10 ppm) and incurred (10-50000 ppm) food matrices were 93.1-125.6% and 35.7-112.2%, respectively. The assay did not register any false-positive or -negative results among the tested commercial and laboratory prepared samples.

  4. Evaluation of a CLEIA automated assay system for the detection of a panel of tumor markers.

    Science.gov (United States)

    Falzarano, Renato; Viggiani, Valentina; Michienzi, Simona; Longo, Flavia; Tudini, Silvestra; Frati, Luigi; Anastasi, Emanuela

    2013-10-01

    Tumor markers are commonly used to detect a relapse of disease in oncologic patients during follow-up. It is important to evaluate new assay systems for a better and more precise assessment, as a standardized method is currently lacking. The aim of this study was to assess the concordance between an automated chemiluminescent enzyme immunoassay system (LUMIPULSE® G1200) and our reference methods using seven tumor markers. Serum samples from 787 subjects representing a variety of diagnoses, including oncologic, were analyzed using LUMIPULSE® G1200 and our reference methods. Serum values were measured for the following analytes: prostate-specific antigen (PSA), alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), carbohydrate antigen 15-3 (CA15-3), carbohydrate antigen 19-9 (CA19-9), and cytokeratin 19 fragment (CYFRA 21-1). For the determination of CEA, AFP, and PSA, an automatic analyzer based on chemiluminescence was applied as reference method. To assess CYFRA 21-1, CA125, CA19-9, and CA15-3, an immunoradiometric manual system was employed. Method comparison by Passing-Bablok analysis resulted in slopes ranging from 0.9728 to 1.9089 and correlation coefficients from 0.9977 to 0.9335. The precision of each assay was assessed by testing six serum samples. Each sample was analyzed for all tumor biomarkers in duplicate and in three different runs. The coefficients of variation were less than 6.3 and 6.2 % for within-run and between-run variation, respectively. Our data suggest an overall good interassay agreement for all markers. The comparison with our reference methods showed good precision and reliability, highlighting its usefulness in clinical laboratory's routine.

  5. Measurement of some tumor markers by IRMA in vietnam

    International Nuclear Information System (INIS)

    Tran Xuan Truong

    2004-01-01

    As we known that a perfect tumor markers could be used in five different ways : for population screening, for diagnose, for monitoring therapy and for follow-up early evidence of cancer recurrence. In order to achieve perfect status a tumor markers would require total negativity in healthy subject, total positivity for single tumor type and close correlation between plasma tumor marker concentration and tumor size . The advance of monoclonal antibodies has had dramatic impact in oncology, where new tumor markers have been discovered and assay methods for all tumor markers have been improved commercially . Analytical performance of these new methods are potentially as good as that of the best Immunoradiometric assay for others analytes. In Vietnam, the first time we use immunoradiometric assay (IRMA) for the measurement of some tumor markers in normal subject and cancer diseases. These are Thyroglobulin (TG) of thyroid cancer, cancer-antigen 15-3 (CA15-3) of breast cancer and cancer-antigen 72-4 (CA72-4) of stomach cancer. We would like applying the CA72-4 in the indication of stomach cancer, CA15-3 in the differential diagnosis of breast cancer, and TG in the differential diagnosis of thyroid cancer. And all of these tumor markers were also used in the clinical follow-up and early detection of recurrence and metastatic Cancer of them. We could try researching on them much more. (authors)

  6. Evaluation of a modified IRMA for anti-D quantitation, using 3H protein A

    International Nuclear Information System (INIS)

    Dumasia, A.; Gupte, S.

    1993-01-01

    A modified immunoradiometric assay (IRMA) using tritiated ( 3 H) protein A was developed to estimate anti-D concentration. The main advantages of the assay were longer shelf life of the labelled reagent (more than two years); minimum radiation hazard and; low non specific binding. Levels of anti-D were estimated in 23 Rh (D) immunized women. A good correlation of anti-D concentration (μg/ml) with Rh antibody titre was observed (r=+ 0.89, P 3 H protein A IRMA correlated well with the severity of Rh-HDN. This assay could quantitate anti-D in sera having exclusively IgG 3 subtype. (author). 20 refs., 2 figs., 2 tabs

  7. Reproductive Hormones Disorders Of Sudanese Infertile Females Using Immunoradiometric assay (IRMA)

    International Nuclear Information System (INIS)

    Ali, N. I.; Almahi, W. A. A.; Abdalla, O. M.; Bafarag, S. M. I.; Abdelgadir, O. M.; Eltayeb, M. A. H.; Hassan, A. M. E.; Hassan, A. M. E.

    2004-01-01

    In this study fertility hormones were measured for 587 infertile Sudanese female referred from gynecological clinics. The ages of these female ranges from 16 - 50 years divided into seven groups. Eighty seven percent of them are in the age range between 21 and 40 year which correlate with the female's fertile period and 5.6% of them under 20 years. Sensitive (IRMA) method was used for measuring the hormone concentration. The objective of this study was to found out the percentage of hormonal disorders and its relation to the age in infertile Sudanese females. The age group (21 - 25) was the most affected group by the Poly-Cystic Ovary Syndrome (PCOS) and represented 5.1% of the total number of patients. The least group was the age group (41- 45) with a percentage of 0.4. The LH and the FSH in the age group of (31- 35) was found to be higher than the other groups and represented 11.4% and 7.8% from the total number of patients respectively. The least percent of high level of LH and FSH was found to be in the most fertile age group (15 - 20) and it was 1.7% and 1.0% from the total number of studied patient, respectively. Those who were in the age range (26 - 30) with hyperprolactinemia represented 10.4% of patients, while those with age range (46 - 50) with hyperprolactinemia represented the lowest percentage (1.2%). The percentage of patients having high LH and high FSH was 44.5% and 29.1% respectively , while the hyperprolactinemia among the infertile Sudanese female was found to 38.2%. (Authors)

  8. Development and evaluation of novel one-step TaqMan realtime RT-PCR assays for the detection and direct genotyping of genogroup I and II noroviruses

    DEFF Research Database (Denmark)

    Schultz, Anna Charlotte; Vega, Everado; Dalsgaard, Anders

    2011-01-01

    BackgroundCurrent detection and genotyping methods of genogroup (G) I and II noroviruses (NoVs) consist of a 2-step approach including detection of viral RNA by TaqMan realtime RT-PCR (RT-qPCR) followed by conventional RT-PCR and sequencing of partial regions of ORF1 or ORF2. ObjectiveTo develop ......Man RT-qPCR assays for the sensitive detection and direct genotyping of GI and GII NoVs from clinical and environmental matrices...... novel long-template one-step TaqMan assays (L-RT-qPCR) for the rapid detection and direct genotyping of GI and GII NoVs and to evaluate the sensitivity and specificity of the assays. Study designGI and GII-specific broadly reactive L-RT-qPCR assays were developed by combining existing NoV primers...... and probes targeting the open reading frame (ORF)1–ORF2 junction as well as region C at the 5′–ORF2. The assays were validated using GI and GII RNA transcripts and a coded panel of 75 stool samples containing NoV strains representing 9 GI genotypes and 12 GII genotypes, as well as sapoviruses, astroviruses...

  9. Development of kits for radioimmunometric assays for tumour markers. Final report of a co-ordinated research project 1997-2001

    International Nuclear Information System (INIS)

    2002-08-01

    in the programme. Efforts in the CRP were focussed on developing and validating methodologies for solid phase immunoradiometric assays (IRMA) for both total and free PSA. The procedures and protocols developed in the participating laboratories for preparation of the primary reagents needed for the assays, including purified PSA, matched pair anti PSA MoAbs, 125 I labelled MoAb tracer, solid phase bound capture MoAb and PSA standards and the different assay formats standardized, are detailed in the report. This report is expected to serve as a good practical guidebook for any one intending to develop IRMA for free or total PSA

  10. Minimization of nonspecific binding to improve the sensitivity of a magnetic immunoradiometric assay (IRMA) for human thyrotropin (hTSH)

    International Nuclear Information System (INIS)

    Peroni, C.N.; Ribela, M.T.C.P.; Bartolini, P.

    1996-01-01

    An IRMA of hTSH, based on magnetic solid phase separation, was studied especially in terms of its nonspecific bindings (B 0 ). These were identified as a product of the interaction between radioiodinated anti-hTSH monoclonal antibody ( 125 I-mAB) and the uncoupled magnetizable cellulose particle (matrix). The negative effects of B 0 on the assay performance were minimized and practically eliminated, in the optimized system, with tracer storage at 4 deg. C, repurification and pre-incubation with the same matrix, serum addition during incubation and solid phase saturation with milk proteins. These findings were used in order to reproducibly decrease non specific binding to values 60 /B 0 ) into values of 300-500. This way, hTSH IRMAs were obtained with functional sensitivities of about 0.05 mlU/L and analytical sensitivities of the order of 0.02 mlU/L, which represent an approximate 10-fold increase in sensitivity when compared with non-optimized system. A more optimistic sensitivity calculation, based on Rodbard's definition, provided values down to 0.008 mlU/L. Such sensitivities, moreover, were obtained in a very reproducible way and all over the useful tracer life. (author). 10 refs, 1 fig., 8 tabs

  11. Three magnetic particles solid phase radioimmunoassay for T4: Comparison of their results with established methods

    International Nuclear Information System (INIS)

    Bashir, T.

    1996-01-01

    The introduction of solid phase separation techniques is an important improvement in radioimmunoassays and immunoradiometric assays. Magnetic particle solid phase method has additional advantages over others, as the separation is rapid and centrifugation is not required. Three types of magnetic particles have been studied in T 4 RIA and the results have been compared with commercial kits and other established methods. (author). 4 refs, 9 figs, 2 tabs

  12. Report of the second research co-ordination meeting of the CRP on development of kits for radioimmunometric assays for tumour markers

    International Nuclear Information System (INIS)

    1999-01-01

    A Co-ordinated Research Programme (CRP) on 'Development of Kits for Immunoradiometric Assays for tumour markers' was started towards the end of 1997. Ten laboratories from different parts of the world with experience in development of immunoassays are participating in this project and the first Research Co-ordination Meeting (RCM) was held at the Agency Head Quarters in Vienna during 3-7 December, 1997. Based on the discussions and recommendations made during this meeting, the participants have carried out the project work at their laboratories during the past 18 months. During this period two consignments (November 98 and March 99) of some of the essential reagents, namely the capture Mab (Mab 66; 5 mg), tracer Mabs (Mab 10; 0.5 mg for total PSA and Mab 30; 0.5 mg for free PSA assay) and PSA antigen (1.3 mg, 80% pure) were shipped to each participant to enable them to develop the assays and to assess their own in-house reagents. The second RCM was held at the University of Alberta, Edmonton, Canada, to review the results obtained thus far and to discuss the actions to be taken in the next phase of the project. All the participants presented the work done at their respective laboratories and discussed the results obtained. On the whole, it was observed that significant progress has been achieved by all the participants. In the area of production of monoclonal antibodies, significant accomplishment was achieved by Cuba, China and India. All the three laboratories had produced monoclonal antibodies against PSA and had been successful to various extents. Cuba could identify specific antibodies that could be used as capture antibody as well as tracer antibodies for free and total PSA assays. Small aliquots of these were brought and distributed to the participants for individual evaluation. China has also identified the monoclonals for an IRMA for total PSA while India had identified a monoclonal that could be used for coating. The selected antibodies have compared very

  13. Usefulness of the mycobacterium tuberculosis direct assay in early diagnosis of extrapulmonary TB

    Directory of Open Access Journals (Sweden)

    Zhang Hui-Zhang

    2014-01-01

    Full Text Available The aim of this study was to evaluate the in situ detection of living mycobacterium TB rRNA by the mycobacterium TB direct assay (MTD and its clinical significance in the early diagnosis of extrapulmonary TB. Eighty-six patients were recruited from the Shanghai Public Health Clinical Center from June to November in 2010, having been diagnosed with extrapulmonary TB, including tuberculous peritonitis (n=22, lymphatic TB (n=21, tuberculous meningitis (n=15, HIV-associated TB (n=13, nephroTB (n=9, spinal TB (n=2, cutaneous TB (n=13, parotid TB (n=1, chest wall TB (n=1, intestinal TB (n=1. One hundred and five extrapulmonary specimens, including CSF, puncture fluid, drainage, pleural fluid, urine, secretion, ascites, lymphatic tissue and marrow were collected from the patients. The samples were examined using acid-fast stain, solid culture, liquid culture and MTD in parallel. In MTD, the target segments of MTB rRNA in either cultures or clinical specimens were amplified prior to being qualitatively detected with the hybridization protection assay (HPA. The sensitivities of MTD and acid-fast staining in liquid and solid cultures were 48.6%, 41.9%, 20.0% and 14.3%, respectively. MTD sensitivity was higher than that of the others and its specificity was 100%. We concluded that MTD rRNA detection is an effective, rapid, convenient, sensitive and reliable method for the early diagnosis of extrapulmonary TB.

  14. A multimedia teaching software for self directed training in steroid receptor assay

    International Nuclear Information System (INIS)

    Ch'ong, S.L.; Myint Aye Mu; Ch'ng, H.M.; Pathmanathan, R.

    1997-01-01

    Use of information technology as one of the instructional tools in problem based learning in the discipline of chemical pathology is receiving widespread interest (1). This will hopefully speed up the process of information access, retrieval, rehearsal, cognitive apprenticeship which will ultimately improve the understanding of chemical pathology and the optimal uses of laboratory investigation techniques. This program is written for self-directed training in steroid receptor assay (we believe to be the first of its kind) with a multimedia software Authorware (purchased from Macromedia, Inc. ) to create a rich blend of animation, colours, graphics, sounds and interactive questions (without giving the answer away). It is hoped that this software can assist the trainee in the process of learning by presenting to him/her sequence of 'related' problems with feedback for success or failure-learning from error, but with assistance - in a real-world job problem or case situated learning- cognitive apprenticeship to assist the trainee in appropriate neuro-networking to make the appropriate response

  15. Acetone enhances the direct analysis of Procyanidin- and Prodelphinidin-based condensed tannins in lotus species by the butanol-HCl-iron assay

    Science.gov (United States)

    The butanol-HCl spectrophotometric assay is widely used for quantifying extractable and insoluble condensed tannins (CT, syn. proanthocyanidins) in foods, feeds, and foliage of herbaceous and woody plants, but the method underestimates total CT content when applied directly to plant material. To imp...

  16. Capillary Electrophoresis Analysis of Conventional Splicing Assays

    DEFF Research Database (Denmark)

    de Garibay, Gorka Ruiz; Acedo, Alberto; García-Casado, Zaida

    2014-01-01

    of these assays is often challenging. Here, we explore this issue by conducting splicing assays in 31 BRCA2 genetic variants. All variants were assessed by RT-PCR followed by capillary electrophoresis and direct sequencing. If assays did not produce clear-cut outputs (Class-2 or Class-5 according to analytical...

  17. Development of direct competitive biomimetic immunosorbent assay based on quantum dot label for determination of trichlorfon residues in vegetables.

    Science.gov (United States)

    Liu, Qiurui; Jiang, Mingdi; Ju, Zeliang; Qiao, Xuguang; Xu, Zhixiang

    2018-06-01

    A direct competitive biomimetic immunosorbent assay method based on molecularly imprinted polymer was developed for the determination of trichlorfon. A CdSe/ZnS quantum dot label was used as the marker. The hydrophilic imprinted film was synthesized directly on the surface of a 96-well plate, and characterized by Fourier-transform infrared spectroscopy and thermo-gravimetric analyses. The method exhibited high stability, selectivity, and sensitivity. Under optimal conditions, the limits of detection and sensitivity of the biomimetic immunosorbent assay method were 9.0 μg L -1 and 5.0 mg L -1 (0.1 mg kg -1 and 62.5 mg kg -1 for vegetable sample), respectively. Low cross-reactivity values of 19.2% and 15.6% were obtained for the structural analogues. Spinach and rape samples spiked with trichlorfon were extracted and determined by this method with recoveries ranging from 83.6% to 91.1%. The method was applied for the detection of trichlorfon residues in leek and cucumber samples, and results correlated well with those obtained using GC. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Detection of hemophilia A carriers by use of frozen plasma samples

    International Nuclear Information System (INIS)

    Yang, H.C.; Hardin, J.; Vaudreuil, C.

    1978-01-01

    The efficacy of using promptly frozen plasma samples in the diagnosis of the carrier state for hemophilia A was evaluated by simultaneous measurement of factor VIII activity and antigen in 20 normal women and 20 obligate carriers. Factor VIII antigen was measured by two methods, electroimmunoassay and immunoradiometric assay. When the factor VIII activity and antigen data were evaluated by regression analysis, 94% of the carriers were correctly identified at the 95% confidence level

  19. Time-resolved immunofluorometric assay of serum ferritin

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Yao [China Inst. of Atomic Energy, Beijing (China)

    2007-06-15

    This assay is a solid phase, two-site fluoroimmunometric assay based on the direct sandwish technique. Standards or samples containing ferritin are first reacted with immobilized anti-ferritin antibodies. Then the europium-lablled antibodies are reacted with the bound antigen. The range of this assay is 2-1000 ng/mL. The analytical sentivity is better than 0.05 ng/mL. The intra-assay variation and inter-assay variation are both below 5%; This kit was compared with Wallac DELFIA kit. The correlation is r=0.96. (authors)

  20. Direct duplex real-time loop mediated isothermal amplification assay for the simultaneous detection of cow and goat species origin of milk and yogurt products for field use.

    Science.gov (United States)

    Kim, Mi-Ju; Kim, Hae-Yeong

    2018-04-25

    A multiple loop-mediated isothermal amplification (LAMP) method was developed to detect cow and goat milk in the field using a portable fluorescence device. For rapid on-site detection, this duplex LAMP assay was used in combination with direct amplification, without DNA extraction. The cow- and goat-specific LAMP primer sets were designed based on the mitochondrial cytochrome b gene, and showed specificity against 13 other animal species in the reactions. The sensitivity of the duplex LAMP assay for cow and goat was 0.1 and 1 pg, respectively. The detection limit for both target species in milk mixtures was 2%. This assay successfully amplified and identified the two target species in 24 samples of commercial milk and yogurt products, with 30 min sampling-to-result analysis time. Therefore, this direct duplex real-time LAMP assay is useful for on-site simultaneous detection of cow and goat milk in commercial products, a capability needed to confirm accurate labeling. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Tumor necrosis factor alpha production in irradiated cells in vitro

    International Nuclear Information System (INIS)

    Koeteles, G.J.; Bognar, G.; Kubasova, T.

    1994-01-01

    Normal and tumor cell lines were used to investigate tumor necrosis factor (TNFα) production and its radiation sensitivity. The cells were irradiated with gamma rays using different doses from 0.25 Gy up to 5 Gy. The number of plated cells, changes of proliferation and TNFα production were determined during the following four post-irradiation days. For TNFα quantity measurement immuno-radiometric assay (IRMA) and enzyme amplified sensitivity assay (EASIA) was used. The results suggest that though gamma irradiation decreased cell proliferation in a dose dependent manner, the quantity produced in the post-irradiation period increased considerably in each irradiated sample. (N.T.) 3 refs.; 2 figs.; 1 tab

  2. Quantitative Fissile Assay In Used Fuel Using LSDS System

    Science.gov (United States)

    Lee, YongDeok; Jeon, Ju Young; Park, Chang-Je

    2017-09-01

    A quantitative assay of isotopic fissile materials (U235, Pu239, Pu241) was done at Korea Atomic Energy Research Institute (KAERI), using lead slowing down spectrometer (LSDS). The optimum design of LSDS was performed based on economics, easy maintenance and assay effectiveness. LSDS system consists of spectrometer, neutron source, detection and control. LSDS system induces fissile fission and fast neutrons are collected at fission chamber. The detected signal has a direct relation to the mass of existing fissile isotopes. Many current commercial assay technologies have a limitation in direct application on isotopic fissile assay of spent fuel, except chemical analysis. In the designed system, the fissile assay model was setup and the correction factor for self-shield was obtained. The isotopic fissile content assay was performed by changing the content of Pu239. Based on the fuel rod, the isotopic content was consistent with 2% uncertainty for Pu239. By applying the covering (neutron absorber), the effective shielding was obtained and the activation was calculated on the target. From the assay evaluation, LSDS technique is very powerful and direct to analyze the isotopic fissile content. LSDS is applicable for nuclear fuel cycle and spent fuel management for safety and economics. Additionally, an accurate fissile content will contribute to the international transparency and credibility on spent fuel.

  3. Competitive binding assay for fructose 2,6-bisphosphate

    International Nuclear Information System (INIS)

    Thomas, H.; Uyeda, K.

    1986-01-01

    A new direct assay method for fructose 2,6-bisphosphate has been developed based on competitive binding of labeled and unlabeled fructose 2,6-P 2 to phosphofructokinase. Phosphofructokinase (0.5-1.3 pmol promoter) is incubated with saturating concentrations (5.0-5.5 pmol) of fructose 2,6[2- 32 P]P 2 and samples containing varying concentrations of fructose 2,6-P 2 . The resulting stable binary complex is retained on nitrocellulose filters with a binding efficiency of up to 70%. Standard curves obtained with this assay show strict linearity with varying fructose 2,6-P 2 in the range of 0.5 to 45 pmol, which exceeds the sensitivity of most of the previously described assay methods. Fructose 2,6-P 2 , ATP, and high concentrations of phosphate interfere with this assay. However, the extent of this inhibition is negligible since their tissue contents are one-half to one-tenth that examined. The new assay is simple, direct, rapid, and does not require pretreatment

  4. Effect of reagins and allergen extracts on radioallergosorbent assays for mite allergen

    International Nuclear Information System (INIS)

    Tovey, E.R.; Vandenberg, R.A.

    1978-01-01

    The reproducibility of the radioallergosorbent (RAST) inhibition and direct binding assays with mite allergen were investigated in the presence of heterogeneous extracts and non-mite sensitive atopic sera. Both contain components similar to potential contaminants which would occur in the assay of mite allergen and dust allergen extracts. The standardized inhibition and direct binding assays employed had a day to day (n = 4) coefficient of variation [(s.d. x 100)/mean] of 15% and 24% respectively. The inhibition assay for mite allergen was reproducible in the presence of protein concentrations of added plant, fungal, arthropod and animal extracts in excess of the protein concentrations that occur under the operational mite assay conditions. The mite inhibition assay was also reproducible in the presence of non-mite allergen extracts, with and without additional sera containing IgE specific for the non0mite allergens. The binding of a constant quantity of mite allergen to the activated solid phase in the direct binding assay was reproducible in the presence of added bovine serum albumin, and of a fungal or arthropod extract, representing the heterogeneous components of an allergen extract at the concentrations of total protein known to occur in the direct binding assay of mite extracts. (author)

  5. Radioreceptor assays: plasma membrane receptors and assays for polypeptide and glycoprotein hormones

    International Nuclear Information System (INIS)

    Schulster, D.

    1977-01-01

    Receptors for peptide, protein and glycoprotein hormones, and the catecholamines are located on the plasma membranes of their target cells. Preparations of the receptors may be used as specific, high-affinity binding agents for these hormones in assay methodology akin to that for radioimmunoassay. A particular advantage of the radioreceptor assay is that it has a specificity directed towards the biologically active region of the hormone, rather than to some immunologically active region that may have little (or no) involvement in the expression of hormonal activity. Methods for hormone receptor preparation vary greatly, and range from the use of intact cells (as the source of hormone receptor) to the use of purified or solubilized membrane receptors. Receptors isolated from plasma membranes have proved to be of variable stability, and may be damaged during preparation and/or storage. Moreover, since they are present in relatively low concentration in the cell, their preparation in sufficient quantity for use in a radioreceptor assay may present technical problems. In general, there is good correlation between radioreceptor assays and in-vitro bioassays; differences between results from radioreceptor assays and radioimmunoassays are similar to those noted between in-vitro bioassays and radioimmunoassays. The sensitivity of the method is such that normal plasma concentrations of various hormones have been assayed by this technique. (author)

  6. Performance of a Multiplex Serological Helicobacter pylori Assay on a Novel Microfluidic Assay Platform

    Directory of Open Access Journals (Sweden)

    Angela Filomena

    2017-10-01

    Full Text Available Infection with Helicobacter pylori (H. pylori occurs in 50% of the world population, and is associated with the development of ulcer and gastric cancer. Serological diagnostic tests indicate an H. pylori infection by detecting antibodies directed against H. pylori proteins. In addition to line blots, multiplex assay platforms provide smart solutions for the simultaneous analysis of antibody responses towards several H. pylori proteins. We used seven H. pylori proteins (FliD, gGT, GroEL, HpaA, CagA, VacA, and HP0231 and an H. pylori lysate for the development of a multiplex serological assay on a novel microfluidic platform. The reaction limited binding regime in the microfluidic channels allows for a short incubation time of 35 min. The developed assay showed very high sensitivity (99% and specificity (100%. Besides sensitivity and specificity, the technical validation (intra-assay CV = 3.7 ± 1.2% and inter-assay CV = 5.5 ± 1.2% demonstrates that our assay is also a robust tool for the analysis of the H. pylori-specific antibody response. The integration of the virulence factors CagA and VacA allow for the assessment of the risk for gastric cancer development. The short assay time and the performance of the platform shows the potential for implementation of such assays in a clinical setting.

  7. An ultrafiltration assay for lysyl oxidase

    International Nuclear Information System (INIS)

    Shackleton, D.R.; Hulmes, D.J.

    1990-01-01

    A modification of the original microdistillation assay for lysyl oxidase is described in which Amicon C-10 microconcentrators are used to separate, by ultrafiltration, the 3H-labeled products released from a [4,5-3H]-lysine-labeled elastin substrate. Enzyme activity is determined by scintillation counting of the ultrafiltrate, after subtraction of radioactivity released in the presence of beta-aminopropionitrile, a specific inhibitor of the enzyme. Conditions are described which optimize both the sensitivity and the efficient use of substrate. The assay shows linear inhibition of activity in up to 1 M urea; hence, as the enzyme is normally diluted in the assay, samples in 6 M urea can be assayed directly, without prior dialysis, and corrected for partial inhibition. Comparable results are obtained when enzyme activity is assayed by ultrafiltration or microdistillation. The assay is simple and convenient and, by using disposable containers throughout, it eliminates the need for time-consuming decontamination of radioactive glassware

  8. Detection of HBsAg and Anti HBc on donors of a blood bank by IRMA and ELISA methods

    International Nuclear Information System (INIS)

    Freire Martinez, D.Y.

    1985-10-01

    Comparative evaluation of two methods, Immunoradiometric Assay (IRMA) and Enzyme Immunoassay (ELISA), for detecting HBsAg and Anti HBc was made for determining which is the most advantageous and reliable. The study was made on 300 donors of the Hospital San Juan de Dios Blood Bank. In comparison with the reference method (IRMA), ELISA shows 91.67% of sensitivity. The Anti HBc detection by IRMA is more reliable than the HBsAg detection by IRMA and ELISA for determining the carrier state

  9. Direct immunofluorescence and enzyme-linked immunosorbent assays for evaluating chlorinated hydrocarbon degrading bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Brigmon, R.L.; Franck, M.M.; Brey, J.; Fliermans, C.B. [Westinghouse Savannah River, Aiken, SC (United States). Environmental Biotechnology Section; Scott, D.; Lanclos, K. [Medical Coll. of Georgia, Augusta, GA (United States)

    1997-06-01

    Immunological procedures were developed to enumerate chlorinated hydrocarbon degrading bacteria. Polyclonal antibodies (Pabs) were produced by immunizing New Zealand white rabbits against 18 contaminant-degrading bacteria. These included methanotrophic and chlorobenzene (CB) degrading species. An enzyme-linked immunosorbent assay (ELISA) was used to test for specificity and sensitivity of the Pabs. Direct fluorescent antibodies (DFAs) were developed with these Pabs against select methanotrophic bacteria isolated from a trichloroethylene (TCE) contaminated landfill at the Savannah River Site (SRS) and cultures from the American Type Culture Collection (ATCC). Analysis of cross reactivity testing data showed some of the Pabs to be group specific while others were species specific. The threshold of sensitivity for the ELISA is 105 bacteria cells/ml. The DFA can detect as few as one bacterium per ml after concentration. Results from the DFA and ELISA techniques for enumeration of methanotrophic bacteria in groundwater were higher but not significantly different (P < 0.05) compared to indirect microbiological techniques such as MPN. These methods provide useful information on in situ community structure and function for bioremediation applications within 1--4 hours of sampling.

  10. Radioactive wastes assay technique and equipment

    International Nuclear Information System (INIS)

    Lee, K. M.; Hong, D. S; Kim, T. K.; Bae, S. M.; Shon, J. S.; Hong, K. P.

    2004-12-01

    The waste inventory records such as the activities and radio- nuclides contained in the waste packages are to be submitted with the radioactive wastes packages for the final disposal. The nearly around 10,000 drums of waste stocked in KAERI now should be assayed for the preparation of the waste inventory records too. For the successive execution of the waste assay, the investigation into the present waste assay techniques and equipment are to be taken first. Also the installation of the waste assay equipment through the comprehensive design, manufacturing and procurement should be proceeded timely. As the characteristics of the KAERI-stocked wastes are very different from that of the nuclear power plant and those have no regular waste streams, the application of the in-direct waste assay method using the scaling factors are not effective for the KAERI-generated wastes. Considering for the versal conveniency including the accuracy over the wide range of waste forms and the combination of assay time and sensitivity, the TGS(Tomographic Gamma Scanner) is appropriate as for the KAERI -generated radioactive waste assay equipment

  11. Summary, the 16th quality control survey for radioisotope in vitro tests in Japan, 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-11-01

    The results of the 16th quality control survey for radioisotope in vitro tests in Japan (1994) are summarized. Of 399 medical facilities conducting radioisotope in vitro tests, 201 were enrolled in this study. Forty items including ACTH and {alpha}-fetoprotein were selected as the subjects. Freeze-drying samples were sent to the facilities. The quality of assay tubes, duration between fusion of the samples and assay, and the condition of preservation were examined, and those influence on the assay values were studied. Radioimmunoassay, immunoradiometric assay, and other procedures using enzymes, fluorescence, and chemiluminescense were conducted. The assay values of some of the items were significantly influenced by repeated freezing and fusion of the samples. Data were collected from individual items and kits used, and analyzed. The significant difference of values between different facilities and kits used were considered due to difference of assay principle, antibodies used, and standard items. The concentration of the samples needs to be improved. (S.Y.).

  12. Comparison of a direct enzymatic assay and polyacrylamide tube gel electrophoresis for measurement of small, dense low-density lipoprotein cholesterol.

    Science.gov (United States)

    Vanavanan, Somlak; Srisawasdi, Pornpen; Rochanawutanon, Mana; Kerdmongkol, Jirapa; Kroll, Martin H

    2015-01-01

    Small, dense low-density lipoprotein cholesterol (sdLDL-C) has been linked to the progression of cardiovascular disease. We compared two methods for determination of sdLDL-C, a direct enzymatic (ENZ) method and a polyacrylamide tube gel electrophoresis (PGE) assay, and investigated the associations of both sdLDL-C measurements with metabolic syndrome. We analyzed 242 patient sera for sdLDL and atherosclerosis-related markers. The PGE method separates the intermediate-density lipoprotein particles into three midbands (MID-A to MID-C) and the LDL particles into seven subfractions (LDL1 to LDL7); the sdLDL-PGE result is calculated as the sum of cholesterol concentrations from LDL3 to LDL7. The regression equation for sdLDL-C was [ENZmmol/L]=0.779[PGE]+0.67, r=0.713. ENZ showed higher sdLDL-C concentrations than PGE (0.86±0.33 vs. 0.24±0.32 mmol/L); however, the difference was not associated with sdLDL-C concentration (p=0.290). sdLDL-C, as measured with the enzymatic assay, exhibited significant positive correlations with very-low-density lipoprotein, MID-C, MID-B, and LDL2 (all p0.600). The ENZ and PGE methods yielded similar patterns of correlation between sdLDL-C, and atherosclerosis-related markers. Using logistic regression, sdLDL-ENZ and apolipoprotein B were identified as significant predictors of metabolic syndrome (p<0.03). The ENZ assay for sdLDL-C correlated well with the PGE method. The ENZ method measures a broader range of atherogenic lipoprotein particles than PGE and has the potential to identify subjects with vascular risk, thus contributing in directing specific interventions for cardiovascular prevention.

  13. Expert system for transuranic waste assay

    Energy Technology Data Exchange (ETDEWEB)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs.

  14. Expert system for transuranic waste assay

    International Nuclear Information System (INIS)

    Zoolalian, M.L.; Gibbs, A.; Kuhns, J.D.

    1989-01-01

    Transuranic wastes are generated at the Savannah River Site (SRS) as a result of routine production of nuclear materials. These wastes contain Pu-238 and Pu-239 and are placed into lined 55-gallon waste drums. The drums are placed on monitored storage pads pending shipment to the Waste Isolation Pilot Plant in New Mexico. A passive-active neutron (PAN) assay system is used to determine the mass of the radioactive material within the waste drums. Assay results are used to classify the wastes as either low-level or transuranic (TRU). During assays, the PAN assay system communicates with an IBM-AT computer. A Fortran computer program, called NEUT, controls and performs all data analyses. Unassisted, the NEUT program cannot adequately interpret assay results. To eliminate this limitation, an expert system shell was used to write a new algorithm, called the Transuranic Expert System (TRUX), to drive the NEUT program and add decision making capabilities for analysis of the assay results. The TRUX knowledge base was formulated by consulting with human experts in the field of neutron assay, by direct experimentation on the PAN assay system, and by observing operations on a daily basis. TRUX, with its improved ability to interpret assay results, has eliminated the need for close supervision by a human expert, allowing skilled technicians to operate the PAN assay system. 4 refs., 1 fig., 4 tabs

  15. Chemiluminescence immunoassay for prostate-specific antigen

    International Nuclear Information System (INIS)

    Zhang Xuefeng; Liu Yibing; Jia Juanjuan; Xu Wenge; Li Ziying; Chen Yongli; Han Shiquan

    2008-01-01

    The chemiluminescence immunoassay (CLIA) for serum total prostate-specific antigen (T-PSA) was developed. The reaction of luminol with hydrogen peroxide was introduced into this chemiluminescence system. The detection limit is established as 0.12 μg/L (n=10, mean of zero standard + 2SD) and the analytical recovery of PSA is 83.8%-118.7%. The intra-assay and inter-assay CVs vary from 4.4%-5.0% and 6.2%-11.7%, respectively. The experimental correlation coefficient of dilution is found to be 0.999. Compared with immunoradiometric assay (IRMA) kits, the correlative equation is y=1.07x+0.68, and correlation coefficient r=0.97. The standard range for the method is 1.5-80 μg/L, and it presents good linearity. (authors)

  16. Prostate-specific antigen superior serum marker for prostatic carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Heaney, J A; Allen, M A; Keane, T; Duffy, J J

    1987-05-01

    A new immunoradiometric assay based on dual monoclonal antibody reaction system (Hybritech-TANDEM/sup R/) was used to measure serum levels of prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) in 39 patients with prostatic carcinoma (CaP), in 57 with benign prostatic hyperplasia (BPH) and in 14 without prostatic disease. Serum PSA was elevated in 82% of patients with CaP while PAP was elevated in only 54%. In this and other studies, PSA is superior to conventional serum markers in sensitivity, prediction of CaP stage and in longitudinal monitoring of disease. A 16% false positive rate precludes PSA as a screening test. The assay used was found to be simple and reliable.

  17. Prostate-specific antigen superior serum marker for prostatic carcinoma

    International Nuclear Information System (INIS)

    Heaney, J.A.; Allen, M.A.; Keane, T.; Duffy, J.J.

    1987-01-01

    A new immunoradiometric assay based on dual monoclonal antibody reaction system (Hybritech-TANDEM R ) was used to measure serum levels of prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) in 39 patients with prostatic carcinoma (CaP), in 57 with benign prostatic hyperplasia (BPH) and in 14 without prostatic disease. Serum PSA was elevated in 82% of patients with CaP while PAP was elevated in only 54%. In this and other studies, PSA is superior to conventional serum markers in sensitivity, prediction of CaP stage and in longitudinal monitoring of disease. A 16% false positive rate precludes PSA as a screening test. The assay used was found to be simple and reliable. (author)

  18. A high-throughput direct fluorescence resonance energy transfer-based assay for analyzing apoptotic proteases using flow cytometry and fluorescence lifetime measurements.

    Science.gov (United States)

    Suzuki, Miho; Sakata, Ichiro; Sakai, Takafumi; Tomioka, Hiroaki; Nishigaki, Koichi; Tramier, Marc; Coppey-Moisan, Maïté

    2015-12-15

    Cytometry is a versatile and powerful method applicable to different fields, particularly pharmacology and biomedical studies. Based on the data obtained, cytometric studies are classified into high-throughput (HTP) or high-content screening (HCS) groups. However, assays combining the advantages of both are required to facilitate research. In this study, we developed a high-throughput system to profile cellular populations in terms of time- or dose-dependent responses to apoptotic stimulations because apoptotic inducers are potent anticancer drugs. We previously established assay systems involving protease to monitor live cells for apoptosis using tunable fluorescence resonance energy transfer (FRET)-based bioprobes. These assays can be used for microscopic analyses or fluorescence-activated cell sorting. In this study, we developed FRET-based bioprobes to detect the activity of the apoptotic markers caspase-3 and caspase-9 via changes in bioprobe fluorescence lifetimes using a flow cytometer for direct estimation of FRET efficiencies. Different patterns of changes in the fluorescence lifetimes of these markers during apoptosis were observed, indicating a relationship between discrete steps in the apoptosis process. The findings demonstrate the feasibility of evaluating collective cellular dynamics during apoptosis. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. QC in RIA

    International Nuclear Information System (INIS)

    Little, J.

    1989-01-01

    A Regional Health Authority expert from the service which performs radioimmunoassays (RIA) and immunoradiometric assays (IRMA) discusses the importance of quality control in these techniques. Originally developed as an aid to endocrinology, applications are now much more widely based and include virology, microbiology, drugs testing, immunology, parasitology, veterinary science and the food industry. The origins of errors in the practice of RIA are examined, with and between batches and the limitations placed on accuracy are explained. Measurement variability between laboratories is also mentioned. (U.K.)

  20. Cryopreservation of human blood for alkaline and Fpg-modified comet assay.

    Science.gov (United States)

    Pu, Xinzhu; Wang, Zemin; Klaunig, James E

    2016-01-01

    The Comet assay is a reproducible and sensitive assay for the detection of DNA damage in eukaryotic cells and tissues. Incorporation of lesion specific, oxidative DNA damage repair enzymes (for example, Fpg, OGG1 and EndoIII) in the standard alkaline Comet assay procedure allows for the detection and measurement of oxidative DNA damage. The Comet assay using white blood cells (WBC) has proven useful in monitoring DNA damage from environmental agents in humans. However, it is often impractical to performance Comet assay immediately after blood sampling. Thus, storage of blood sample is required. In this study, we developed and tested a simple storage method for very small amount of whole blood for standard and Fpg-modified modified Comet assay. Whole blood was stored in RPMI 1640 media containing 10% FBS, 10% DMSO and 1 mM deferoxamine at a sample to media ratio of 1:50. Samples were stored at -20 °C and -80 °C for 1, 7, 14 and 28 days. Isolated lymphocytes from the same subjects were also stored under the same conditions for comparison. Direct DNA strand breakage and oxidative DNA damage in WBC and lymphocytes were analyzed using standard and Fpg-modified alkaline Comet assay and compared with freshly analyzed samples. No significant changes in either direct DNA strand breakage or oxidative DNA damage was seen in WBC and lymphocytes stored at -20 °C for 1 and 7 days compared to fresh samples. However, significant increases in both direct and oxidative DNA damage were seen in samples stored at -20 °C for 14 and 28 days. No changes in direct and oxidative DNA damage were observed in WBC and lymphocytes stored at -80 °C for up to 28 days. These results identified the proper storage conditions for storing whole blood or isolated lymphocytes to evaluate direct and oxidative DNA damage using standard and Fpg-modified alkaline Comet assay.

  1. Clinical evaluation of the Abbott RealTime MTB Assay for direct detection of Mycobacterium tuberculosis-complex from respiratory and non-respiratory samples.

    Science.gov (United States)

    Hinić, Vladimira; Feuz, Kinga; Turan, Selda; Berini, Andrea; Frei, Reno; Pfeifer, Karin; Goldenberger, Daniel

    2017-05-01

    Rapid and reliable diagnosis is crucial for correct management of tuberculosis. The Abbott RealTime MTB Assay represents a novel qualitative real-time PCR assay for direct detection of M. tuberculosis-complex (MTB) DNA from respiratory samples. The test targets two highly conserved sequences, the multi-copy insertion element IS6110 and the protein antigen B (PAB) gene of MTB, allowing even the detection of IS6610-deficient strains. We evaluated this commercial diagnostic test by analyzing 200 respiratory and, for the first time, 87 non-respiratory clinical specimens from our tertiary care institution and compared its results to our IS6110-based in-house real-time PCR for MTB as well as MTB culture. Overall sensitivity for Abbott RealTime MTB was 100% (19/19) in smear positive and 87.5% (7/8) in smear negative specimens, while the specificity of the assay was 100% (260/260). For both non-respiratory smear positive and smear negative specimens Abbott RealTime MTB tests showed 100% (8/8) sensitivity and 100% (8/8) specificity. Cycle threshold (Ct) value analysis of 16 MTB positive samples showed a slightly higher Ct value of the Abbott RealTime MTB test compared to our in-house MTB assay (mean delta Ct = 2.55). In conclusion, the performance of the new Abbott RealTime MTB Assay was highly similar to culture and in-house MTB PCR. We document successful analysis of 87 non-respiratory samples with the highly automated Abbott RealTime MTB test with no inhibition observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Identification of dioxin-like and estrogenic compounds in sediment using CALUX {sup registered} assay-directed fractionation combined with two-dimensional comprehensive GCxGC-ToF MS

    Energy Technology Data Exchange (ETDEWEB)

    Houtman, C.; Lamoree, M.; Legler, J.; Brouwer, A. [Vrije Univ., Amsterdam (Netherlands). Inst. for Environmental Studies; Jover, E. [I.I.Q.A.B.-C.S.I.C., Barcelona (Spain). Dept. of Environmental Chemistry; Adahchour, M. [Vrije Univ., Amsterdam (Netherlands). Dept. of Analytical Chemistry and Applied Spectroscopy

    2004-09-15

    The dioxin responsive (DR-) and estrogen responsive (ER-) CALUX {sup registered} -assays (Chemical Activated Luciferase Gene Expression) are mechanism-based, rapid and extremely sensitive in vitro reporter gene bioassays developed to assess dioxin-like and estrogenic activity. They provide useful information about the total dioxin-like or estrogenic potential of complex mixtures of chemicals in environmental samples. They are especially useful if combined with instrumental analytical approaches, as e.g. in bioassay-directed fractionation. In this approach, bioassays are used to direct fractionation and chemical analysis in order to elucidate compounds responsible for the toxic activity found in a sample. The present study was undertaken to elucidate dioxin-like and estrogenic chemicals in sediment from the harbor of the small town of Zierikzee in the Dutch delta area. Former research had shown high dioxin-like and estrogenic activity in sediment from this location. DR- and ER-CALUX {sup registered} assay were used to direct fractionation and chemical analysis of sediment extract. Active fractions were analyzed with comprehensive multidimensional GC x GC-Time-of-Flight Mass Spectrometry to elucidate responsible compounds.

  3. Comparative analysis of enzyme-linked immunosorbent assay and direct microscopy for the diagnosis of Giardia intestinalis in fecal samples

    Directory of Open Access Journals (Sweden)

    Shipra Singhal

    2015-01-01

    Full Text Available Context: Giardiasis is one of the most common nonviral infections causing diarrheal illness worldwide. In this prospective cross-sectional study, we evaluated the RIDASCREEN ® Giardia kit for detection of Giardia intestinalis in stool samples and compared the results with direct microscopy. Materials and methods: A total of 360 fecal samples were collected. They were then processed by wet film, iodine preparation and an enzyme-linked immunosorbent assay (ELISA kit to determine the presence of Giardia trophozoites and cysts. Statistical analysis was performed by sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy. Results and Conclusion: Of the 360 cases, 17.2% samples were positive for Giardia by direct microscopy and 23.6% were found to be positive by ELISA (sensitivity ~97%, but specificity was ~92% only. Because of less specificity, we need to perform ELISA in congruence with direct microscopy, etc. Further studies need to be performed on a larger sample size using other molecular tests in order to get more accurate estimations.

  4. Unsaturated fatty acids show clear elicitation responses in a modified local lymph node assay with an elicitation phase, and test positive in the direct peptide reactivity assay.

    Science.gov (United States)

    Yamashita, Kunihiko; Shinoda, Shinsuke; Hagiwara, Saori; Miyazaki, Hiroshi; Itagaki, Hiroshi

    2015-12-01

    The Organisation for Economic Co-operation and Development (OECD) Test Guidelines (TG) adopted the murine local lymph node assay (LLNA) and guinea pig maximization test (GPMT) as stand-alone skin sensitization test methods. However, unsaturated carbon-carbon double-bond and/or lipid acids afforded false-positive results more frequently in the LLNA compared to those in the GPMT and/or in human subjects. In the current study, oleic, linoleic, linolenic, undecylenic, fumaric, maleic, and succinic acid and squalene were tested in a modified LLNA with an elicitation phase (LLNA:DAE), and in a direct peptide reactivity assay (DPRA) to evaluate their skin-sensitizing potential. Oleic, linoleic, linolenic, undecylenic and maleic acid were positive in the LLNA:DAE, of which three, linoleic, linolenic, and maleic acid were positive in the DPRA. Furthermore, the results of the cross-sensitizing tests using four LLNA:DAE-positive chemicals were negative, indicating a chemical-specific elicitation response. In a previous report, the estimated concentration needed to produce a stimulation index of 3 (EC3) of linolenic acid, squalene, and maleic acid in the LLNA was LLNA. However, the skin-sensitizing potential of all LLNA:DAE-positive chemicals was estimated as weak. These results suggested that oleic, linoleic, linolenic, undecylenic, and maleic acid had skin-sensitizing potential, and that the LLNA overestimated the skin-sensitizing potential compared to that estimated by the LLNA:DAE.

  5. Successful kidney transplantation across a positive complement-dependent cytotoxicity crossmatch by using C1q assay-directed, bortezomib-assisted desensitization

    Science.gov (United States)

    Lee, Juhan; Park, Borae G.; Jeong, Hyang Sook; Park, Youn Hee; Kim, Sinyoung; Kim, Beom Seok; Kim, Hye Jin; Huh, Kyu Ha; Jeong, Hyeon Joo; Kim, Yu Seun

    2017-01-01

    Abstract Rationale: Human leukocyte antigen (HLA) is the major immunologic barrier in kidney transplantation (KT). Various desensitization protocols to overcome the HLA barrier have increased the opportunity for transplantation in sensitized patients. In addition, technological advances in solid-phase assays have permitted more comprehensive assessment of donor-specific antibodies. Although various desensitization therapies and immunologic techniques have been developed, the final transplantation decision is still based on the classic complement-dependent cytotoxicity (CDC) crossmatch (XM) technique. Some patients who fail to achieve negative XM have lost their transplant opportunities, even after receiving sufficient desensitization therapies. Patient concerns: A 57-year-old male with end-stage renal disease secondary to chronic glomerulonephritis was scheduled to have a second transplant from his son, but CDC XM was positive. Diagnoses: Initial CDC XM (Initial T-AHG 1:32) and flow-cytometry XM were positive. Anti-HLA-B59 donor specific antibody was detected by Luminex single antigen assay. Interventions: Herein, we report a successful case of KT across a positive CDC XM (T-AHG 1:8 at the time of transplantation) by using C1q assay-directed, bortezomib-assisted desensitization. After confirming a negative conversion in the C1q donor-specific antibody, we decided to perform KT accepting a positive AHG-CDC XM of 1:8 at the time of transplantation. Outcomes: The posttransplant course was uneventful and a protocol biopsy at 3 months showed no evidence of rejection. The patient had excellent graft function at 12 months posttransplant. Lessons: The results of XM test and solid-phase assay should be interpreted in the context of the individual patient. PMID:28953652

  6. Protein subcellular localization assays using split fluorescent proteins

    Science.gov (United States)

    Waldo, Geoffrey S [Santa Fe, NM; Cabantous, Stephanie [Los Alamos, NM

    2009-09-08

    The invention provides protein subcellular localization assays using split fluorescent protein systems. The assays are conducted in living cells, do not require fixation and washing steps inherent in existing immunostaining and related techniques, and permit rapid, non-invasive, direct visualization of protein localization in living cells. The split fluorescent protein systems used in the practice of the invention generally comprise two or more self-complementing fragments of a fluorescent protein, such as GFP, wherein one or more of the fragments correspond to one or more beta-strand microdomains and are used to "tag" proteins of interest, and a complementary "assay" fragment of the fluorescent protein. Either or both of the fragments may be functionalized with a subcellular targeting sequence enabling it to be expressed in or directed to a particular subcellular compartment (i.e., the nucleus).

  7. Radioenzymatic assay of DOPA (3,4-dihydroxyphenylalanine)

    International Nuclear Information System (INIS)

    Johnson, G.A.; Gren, J.M.; Kupiecki, R.

    1978-01-01

    We modified the single-isotope radioenzymatic assay for catecholamines [Life Sci. 21, 625(1977)] to assay 3,4-dihydroxyphenylalanine (DOPA). DOPA decarboxylase is used to convert DOPA to dopamine, which concurrently is converted to [ 3 H]-3-O-methyldopamine in the presence of catechol-O-methyltransferase and [methyl- 3 H]-S-adenosylmethionine and assayed radioenzymatically. For assay of plasma DOPA, 50 μl of untreated plasma is added directly into the incubation mixture. A duplicate mixture containing an internal standard requires a second 50-μl aliquot of plasma. Because the assay measures both DOPA and endogenous dopamine, two additional aliquots of plasma must be assayed for dopamine in the absence of the decarboxylase by the differential assay; DOPA is estimated by difference. The assay is sensitive to 25 pg (500 ng/liter of plasma). Analysis of DOPA (DOPA plus dopamine) and the concurrent differential assay of catecholamines in at least 10 samples can be done in a single working day. Plasma DOPA concentrations for 42 normotensive adults were 1430 +- 19 ng/liter (mean +- SEM). In contrast, dopamine concentrations for these same subjects averaged 23 +- 20 ng/liter. Values for the 24 women subjects (1510 +- 62 ng/liter) significantly (P = 0.04) exceeded those for the men

  8. Ecotoxicological Assessment of Aquatic Genotoxicity Using the Comet Assay

    Directory of Open Access Journals (Sweden)

    KHUSNUL YAQIN

    2006-09-01

    Full Text Available Comet assay is a novel biological analysis, which is a sensitive, flexible, simple, rapid, and inexpensive method to assess aquatic genotoxicant. Since Singh and co-workers developed the method in 1988, its use has increased exponentially in various fields. This review discourses on the application of this assay in aquatic ecosystems. Various types of cells from various aquatic organisms have been tested by various genotoxicant both direct- and indirect-acting using the comet assay. The applications of this assay suggest that it is a useful assay to assess aquatic genotoxicants. However, there are some factors, which should be taken into account when using this assay as aquatic ecotoxicological assessment device such as inter-animal and cell variability.

  9. Radioimmunoassay apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Apparatus for performing a quantitative radioimmunoassay comprising: a substantially spherical bead for carrying an antibody and a gripper for gripping said bead, said gripper comprising an integrally formed unit having a single elongate handle portion and a plurality of resilient fingers arranged at the base of the handle so that when said bead is secured within said fingers, said bead may be freely rotated about any diametric axis of the bead. In particular the invention relates to an apparatus for a two site immunoradiometric assay for serum ferritin in human blood samples. (author)

  10. Comparison of multiple assays for detecting human antibodies directed against antigens on normal and malignant tissue culture cells

    International Nuclear Information System (INIS)

    Rosenberg, S.A.; Schwarz, S.; Anding, H.; Hyatt, C.; Williams, G.M.; Johns Hopkins Univ., Baltimore, Md.

    1977-01-01

    Four separate assays of human antibody reactivity to four separate normal and malignant human tissue culture cells lines from two patients have been evaluated using a single highly-reactive allogeneic serum. The visual end-point cytolysis assay and the chromium-51 release assay were equally sensitive in measuring complement mediated antibody cytotoxicity and both were far more sensitive than a trypan blue dye exclusion assay. The assay of antibody reactivity by hemadsorption technique was about 10 times more sensitive than any of the cytotoxicity assays. This latter assay measures only IgG antibody however. These assays showed that cell lines from different patients may differ greatly in 'reactivity' to an allogeneic serum and emphasized the importance of utilizing tumor and normal cells from the same patient when using tissue culture cells to search for tumor specific reactivity. These observations emphasize the importance of utilizing multiple assays against paired normal and malignant cells from the same patient to be certain of the specificity and magnitude of the measured antibody

  11. Hyperpolarized NMR Probes for Biological Assays

    Directory of Open Access Journals (Sweden)

    Sebastian Meier

    2014-01-01

    Full Text Available During the last decade, the development of nuclear spin polarization enhanced (hyperpolarized molecular probes has opened up new opportunities for studying the inner workings of living cells in real time. The hyperpolarized probes are produced ex situ, introduced into biological systems and detected with high sensitivity and contrast against background signals using high resolution NMR spectroscopy. A variety of natural, derivatized and designed hyperpolarized probes has emerged for diverse biological studies including assays of intracellular reaction progression, pathway kinetics, probe uptake and export, pH, redox state, reactive oxygen species, ion concentrations, drug efficacy or oncogenic signaling. These probes are readily used directly under natural conditions in biofluids and are often directly developed and optimized for cellular assays, thus leaving little doubt about their specificity and utility under biologically relevant conditions. Hyperpolarized molecular probes for biological NMR spectroscopy enable the unbiased detection of complex processes by virtue of the high spectral resolution, structural specificity and quantifiability of NMR signals. Here, we provide a survey of strategies used for the selection, design and use of hyperpolarized NMR probes in biological assays, and describe current limitations and developments.

  12. An in-house assay is superior to Sepsityper for direct matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry identification of yeast species in blood cultures.

    Science.gov (United States)

    Bidart, Marie; Bonnet, Isabelle; Hennebique, Aurélie; Kherraf, Zine Eddine; Pelloux, Hervé; Berger, François; Cornet, Muriel; Bailly, Sébastien; Maubon, Danièle

    2015-05-01

    We developed an in-house assay for the direct identification, by matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry, of yeasts in blood culture. Sixty-one representative strains from 12 species were analyzed in spiked blood cultures. Our assay accurately identified 95 of 107 (88.8%) positive blood cultures and outperformed the commercial Sepsityper kit (81.7% identification). Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  13. Assay of oestrogen

    International Nuclear Information System (INIS)

    Edwards, J.C.

    1981-01-01

    A particular problem with the direct radioimmunoassay of unconjugated oestriol in pregnancy is caused by the increased amount of steroid-binding proteins present in pregnancy serum and plasma. The steroid-binding proteins react with oestriol and 125 I-labelled oestriol during the assay procedure and the steroid-protein bound 125 I-labelled oestriol is precipitated along with the antibody-bound 125 I-labelled oestriol by the ammonium sulphate solution separation system. A novel method is described whereby progesterone (1-20 μg/ml) is used to block the action of steroid-binding proteins in pregnancy serum and plasma samples, thus minimizing interference in a direct radioimmunoassay for unconjugated oestriol using a specific anti-oestriol serum. (U.K.)

  14. Effects of the oral, direct thrombin inhibitor dabigatran on five common coagulation assays.

    Science.gov (United States)

    Lindahl, Tomas L; Baghaei, Fariba; Blixter, Inger Fagerberg; Gustafsson, Kerstin M; Stigendal, Lennart; Sten-Linder, Margareta; Strandberg, Karin; Hillarp, Andreas

    2011-02-01

    Dabigatran is an oral, reversible thrombin inhibitor that has shown promising results in large clinical trials. Laboratory monitoring is not needed but the effects on common coagulation assays are incompletely known. Dabigatran was added to plasma from healthy subjects in the concentration range 0-1,000 μg/l and analysed using several reagents for activated thromboplastin time (APTT), prothrombin time (PT), fibrinogen, antithrombin, and activated protein C resistance. Typical trough concentrations are about 50 μg/l, peak concentrations 100-300 μg/l. At 100 μg/l all APTT-results were prolonged. The concentration required to double APTT ranged between 227 and 286 μg/l, the responses for all five reagents were similar. PT-reagents were much less affected with almost no samples above INR 1.2 at 100 μg/l. The effect was sample dilution dependent with PT Quick type more sensitive than PT Owren type methods. If a patient on dabigatran has prolonged APTT, >90 seconds, and Quick PT INR>2 or Owren PT INR>1.5 over-dosing or accumulation of dabigatran should be considered. Two of four fibrinogen reagents underestimated the fibrinogen concentration considerably at expected peak concentration. Methods based on inhibition of thrombin over-estimated the antithrombin concentration, but not Xa-based. The APC-resistance methods over-estimated the APC-ratio, which may lead to miss-classification of factor V Leiden patients as being normal. Different coagulation assays, and even different reagents within an assay group, display variable effects at therapeutic concentrations of dabigatran. Some of these assay variations are of clinical importance, thus knowledge is needed for a correct interpretation of results.

  15. Transuranic waste assay instrumentation: new developments and directions at the Los Alamos Scientific Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Close, D.A.; Umbarger, C.J.; West, L.; Smith, W.J.; Cates, M.R.; Noel, B.W.; Honey, F.J.; Franks, L.A.; Pigg, J.L.; Trundle, A.S.

    1978-01-01

    The Los Alamos Scientific Laboratory is developing assay instrumentation for the quantitative analysis of transuranic materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. This also includes wastes generated in the decontamination and decommissioning of facilities and wastes generated during burial ground exhumation. The assay instrumentation will have a detection capability for the transuranics of less than 10 nCi of activity per gram of waste whenever practicable.

  16. Transuranic waste assay instrumentation: new developments and directions at the Los Alamos Scientific Laboratory

    International Nuclear Information System (INIS)

    Close, D.A.; Umbarger, C.J.; West, L.; Smith, W.J.; Cates, M.R.; Noel, B.W.; Honey, F.J.; Franks, L.A.; Pigg, J.L.; Trundle, A.S.

    1978-01-01

    The Los Alamos Scientific Laboratory is developing assay instrumentation for the quantitative analysis of transuranic materials found in bulk solid wastes generated by Department of Energy facilities and by the commercial nuclear power industry. This also includes wastes generated in the decontamination and decommissioning of facilities and wastes generated during burial ground exhumation. The assay instrumentation will have a detection capability for the transuranics of less than 10 nCi of activity per gram of waste whenever practicable

  17. Cytosol cathepsin-D content and proliferative activity of human breast cancer. The Comitato Italiano per il Controllo di Qualita del Laboratorio in Oncologia.

    Science.gov (United States)

    Paradiso, A; Mangia, A; Correale, M; Abbate, I; Ferri, G; Piffanelli, A; Catozzi, L; Amadori, D; Riccobon, A; De Lena, M

    1992-01-01

    Mitogenic properties have been demonstrated in vitro for the lysosomal acidic protease cathepsin-D (cath-D). We investigated possible relationships between cath-D cytosol cell content and tumor proliferative activity in a series of 129 operable breast cancer patients. For total cytosol cath-D evaluation, a solid phase two-site immunoradiometric assay was utilized on tumor cell cytosol obtained for hormone receptor assay (DCC method). The percentage of S-phase cells was analyzed by 3H-thymidine autoradiographic assay. Median 3H-thymidine Labeling Index (3H-Tdr-LI) of the series was 2.7%; median cath-D content resulted 57 pmol/mg of protein cytosol and was significantly higher in node-positive with respect to the node-negative subgroup (p < 0.03). When classified in low, intermediate or high tumor cath-D content and slow or fast proliferative activity (cut-off: median values of the series), no significant agreement was found between the two variables. Statistical analysis, however, showed that a significant inverse correlation existed in node positive tumors between cath-D and 3H-Tdr-LI values which was even more evident in N-positive high estrogen receptor-positive (ER+) cases (coefficient of correlation = 0.6828; p = 0.0001). Cytosol cath-D content cannot be generally proposed as a direct marker of proliferative activity for operable breast cancer.

  18. Development of fluorescent methods for DNA methyltransferase assay

    Science.gov (United States)

    Li, Yueying; Zou, Xiaoran; Ma, Fei; Tang, Bo; Zhang, Chun-yang

    2017-03-01

    DNA methylation modified by DNA methyltransferase (MTase) plays an important role in regulating gene transcription, cell growth and proliferation. The aberrant DNA MTase activity may lead to a variety of human diseases including cancers. Therefore, accurate and sensitive detection of DNA MTase activity is crucial to biomedical research, clinical diagnostics and therapy. However, conventional DNA MTase assays often suffer from labor-intensive operations and time-consuming procedures. Alternatively, fluorescent methods have significant advantages of simplicity and high sensitivity, and have been widely applied for DNA MTase assay. In this review, we summarize the recent advances in the development of fluorescent methods for DNA MTase assay. These emerging methods include amplification-free and the amplification-assisted assays. Moreover, we discuss the challenges and future directions of this area.

  19. Effect-directed fingerprints of 77 botanical extracts via a generic high-performance thin-layer chromatography method combined with assays and mass spectrometry.

    Science.gov (United States)

    Krüger, S; Hüsken, L; Fornasari, R; Scainelli, I; Morlock, G E

    2017-12-22

    Quantitative effect-directed profiles of 77 industrially and freshly extracted botanicals like herbs, spices, vegetables and fruits, widely used as food ingredients, dietary supplements or traditional medicine, gave relevant information on their quality. It allows the assessment of food, dietary supplements and phytomedicines with regard to potential health-promoting activities. In contrary to sum parameter assays and targeted analysis, chromatography combined with effect-directed analysis allows fast assignment of single active compounds and evaluation of their contribution to the overall activity, originating from a food or botanical sample. High-performance thin-layer chromatography was hyphenated with UV/Vis/FLD detection and effect-directed analysis, using the 2,2-diphenyl-1-picrylhydrazyl radical, Gram-negative Aliivibrio fischeri, Gram-positive Bacillus subtilis, acetylcholinesterase and tyrosinase assays. Bioactive compounds of interest were eluted using an elution head-based interface and further characterized by electrospray ionization (high-resolution) mass spectrometry. This highly streamlined workflow resulted in a hyphenated HPTLC-UV/Vis/FLD-EDA-ESI + /ESI - -(HR)MS method. The excellent quantification power of the method was shown on three compounds. For rosmarinic acid, contents ranged from 4.5mg/g (rooibos) to 32.6mg/g (rosemary), for kaempferol-3-glucoside from 0.6mg/g (caraway) to 4.4mg/g (wine leaves), and for quercetin-3-glucoside from 1.1mg/g (hawthorn leaves) to 17.7mg/g (thyme). Three mean repeatabilities (%RSD) over 18 quantifications for the three compounds were ≤2.2% and the mean intermediate precision over three different days (%RSD, n=3) was 5.2%. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. A multiplex branched DNA assay for parallel quantitative gene expression profiling.

    Science.gov (United States)

    Flagella, Michael; Bui, Son; Zheng, Zhi; Nguyen, Cung Tuong; Zhang, Aiguo; Pastor, Larry; Ma, Yunqing; Yang, Wen; Crawford, Kimberly L; McMaster, Gary K; Witney, Frank; Luo, Yuling

    2006-05-01

    We describe a novel method to quantitatively measure messenger RNA (mRNA) expression of multiple genes directly from crude cell lysates and tissue homogenates without the need for RNA purification or target amplification. The multiplex branched DNA (bDNA) assay adapts the bDNA technology to the Luminex fluorescent bead-based platform through the use of cooperative hybridization, which ensures an exceptionally high degree of assay specificity. Using in vitro transcribed RNA as reference standards, we demonstrated that the assay is highly specific, with cross-reactivity less than 0.2%. We also determined that the assay detection sensitivity is 25,000 RNA transcripts with intra- and interplate coefficients of variance of less than 10% and less than 15%, respectively. Using three 10-gene panels designed to measure proinflammatory and apoptosis responses, we demonstrated sensitive and specific multiplex gene expression profiling directly from cell lysates. The gene expression change data demonstrate a high correlation coefficient (R(2)=0.94) compared with measurements obtained using the single-plex bDNA assay. Thus, the multiplex bDNA assay provides a powerful means to quantify the gene expression profile of a defined set of target genes in large sample populations.

  1. Development of an artificial neural network model for risk assessment of skin sensitization using human cell line activation test, direct peptide reactivity assay, KeratinoSens™ and in silico structure alert parameter.

    Science.gov (United States)

    Hirota, Morihiko; Ashikaga, Takao; Kouzuki, Hirokazu

    2018-04-01

    It is important to predict the potential of cosmetic ingredients to cause skin sensitization, and in accordance with the European Union cosmetic directive for the replacement of animal tests, several in vitro tests based on the adverse outcome pathway have been developed for hazard identification, such as the direct peptide reactivity assay, KeratinoSens™ and the human cell line activation test. Here, we describe the development of an artificial neural network (ANN) prediction model for skin sensitization risk assessment based on the integrated testing strategy concept, using direct peptide reactivity assay, KeratinoSens™, human cell line activation test and an in silico or structure alert parameter. We first investigated the relationship between published murine local lymph node assay EC3 values, which represent skin sensitization potency, and in vitro test results using a panel of about 134 chemicals for which all the required data were available. Predictions based on ANN analysis using combinations of parameters from all three in vitro tests showed a good correlation with local lymph node assay EC3 values. However, when the ANN model was applied to a testing set of 28 chemicals that had not been included in the training set, predicted EC3s were overestimated for some chemicals. Incorporation of an additional in silico or structure alert descriptor (obtained with TIMES-M or Toxtree software) in the ANN model improved the results. Our findings suggest that the ANN model based on the integrated testing strategy concept could be useful for evaluating the skin sensitization potential. Copyright © 2017 John Wiley & Sons, Ltd.

  2. Desomorphine Screening Using Commercial Enzyme-Linked Immunosorbent Assays.

    Science.gov (United States)

    Winborn, Jessica; Kerrigan, Sarah

    2017-06-01

    Desomorphine ("Krokodil") is a semi-synthetic opioid that has drawn attention as a recreational drug, particularly in Russia, neighboring former Soviet Republics, Eastern and Central Europe. It has no accepted medicinal uses and is currently a schedule I drug in the United States. In clandestine environments, desomorphine is synthesized from codeine using red phosphorous, hydroiodic acid and gasoline. Residual starting materials in illicit preparations have been associated with severe dermatological effects and extensive tissue necrosis. Desomorphine is not well studied, and there are limited reports concerning its pharmacology or detection in biological matrices. Immunoassays are widely relied upon for both antemortem and postmortem toxicology screening. Although desomorphine is an opioid of the phenanthrene-type, its ability to bind to conventional opioid antibodies has not been described. In this report we describe the cross-reactivity of desomorphine using six commercially available enzyme-linked immunosorbent assays (Immunalysis Opiates Direct ELISA, Immunalysis Oxycodone/Oxymorphone Direct ELISA, Randox Opiate ELISA, OraSure Technologies OTI Opiate Micro-plate EIA, Neogen Opiate Group ELISA and Neogen Oxycodone/Oxymorphone ELISA). Cross-reactivites were highly variable between assays, ranging from 77 to desomorphine than those directed towards oxycodone. The Immunalysis Opiates Direct ELISA produced the greatest cross-reactivity, although several of the assays evaluated produced cross-reactivity of a sufficient magnitude to be effective for desomorphine screening. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Development of an immunoradiometric method for the measurement of total PSA

    International Nuclear Information System (INIS)

    Venkatesh, M.; Korde, A.; Bapat, K.; Shukla, A.; Pillai, M.R.A.

    1999-01-01

    Development of an IRMA for total-PSA was taken up in our laboratories (Isotope Division, Bhabha Atomic Research Centre, Mumbai, India) and efforts were made to obtain monoclonals for PSA at our laboratory. Following the guidelines laid at the first meeting of this CRP we have used the reagents supplied by the Agency as well as our inhouse reagents, and attempted to develop assay procedures for measuring total-PSA in human sera

  4. Rapid, radiochemical-ligand binding assay for methotrexate

    International Nuclear Information System (INIS)

    Caston, J.D.

    1976-01-01

    A radiochemical ligand binding assay for methotrexate is provided. A binder factor comprising a partially purified dihydrofolic acid reductase preparation is employed. The binder factor is conveniently prepared by homogenizing a factor containing animal organ such as liver, and extracting with isotonic saline and ammonium sulfate. A binder cofactor, NADPH 2 , is also employed in the binding reaction. The procedure contemplates both direct and sequential assay techniques, and it is not interfered with by vast excesses of many natural folate derivatives. 12 claims, 6 drawing figures

  5. Ultrasensitive TSH: a new approach to hyperthyroidism diagnosis

    International Nuclear Information System (INIS)

    Gibold, G.; Liehn, J.C.; Deltour, G.; Delisle, M.J.

    1986-01-01

    The value of new ultrasensible and rapid immunoradiometric assay of thyroid stimulating hormone (TSH) for the diagnosis of hyperthyroidism was assessed in 130 patients with suspected hyperthyroidism and in 330 controls. The diagnosis was established by the clinical evaluation, thyroid scintigraphy and serum concentrations of thyroid hormones. Using the ROC (Receiver Operating Characteristic) curve methodology which allows the optimization of sensitivity and specificity, the physician can choose the Cut-off value between hyperthyroidism and euthyroidism. Two points of the curve seem to be interesting: using the cut-off value of 0.1 mUI/1, sensitivity is 0.98 and specificity is 0.98; using the cut-off value of 0.3 mUI/1, sensitivity is 1.00 and specificity is 0.92. Using the association TSH and FT4 (Free Thyroxin), sensitivity is 0.94 and specificity is 0.99. Sixty four per cent of euthyroid patients with TSH under 0.3 mUI/1 have one or several hot nodules and only two have no thyroid disease. A TRH (Thyrotrophin Releasing Hormone) test was carried out in 63 patients with suspected thyrotoxicosis: basal and TRH stimulated TSH levels were under 0.1 mUI/1. This immunoradiometric assay for TSH may simplify the approach to thyroid function testing in patients with suspected thyrotoxicosis: a basal TSH under 0.3 mUI/1 is sufficient to confirm a clinical suspicion of thyrotoxicosis without TRH test within four hours. In a department devoted to testing thyroid function, this new method provides a great benefit in cost and work [fr

  6. CLSI-based transference of the CALIPER database of pediatric reference intervals from Abbott to Beckman, Ortho, Roche and Siemens Clinical Chemistry Assays: direct validation using reference samples from the CALIPER cohort.

    Science.gov (United States)

    Estey, Mathew P; Cohen, Ashley H; Colantonio, David A; Chan, Man Khun; Marvasti, Tina Binesh; Randell, Edward; Delvin, Edgard; Cousineau, Jocelyne; Grey, Vijaylaxmi; Greenway, Donald; Meng, Qing H; Jung, Benjamin; Bhuiyan, Jalaluddin; Seccombe, David; Adeli, Khosrow

    2013-09-01

    The CALIPER program recently established a comprehensive database of age- and sex-stratified pediatric reference intervals for 40 biochemical markers. However, this database was only directly applicable for Abbott ARCHITECT assays. We therefore sought to expand the scope of this database to biochemical assays from other major manufacturers, allowing for a much wider application of the CALIPER database. Based on CLSI C28-A3 and EP9-A2 guidelines, CALIPER reference intervals were transferred (using specific statistical criteria) to assays performed on four other commonly used clinical chemistry platforms including Beckman Coulter DxC800, Ortho Vitros 5600, Roche Cobas 6000, and Siemens Vista 1500. The resulting reference intervals were subjected to a thorough validation using 100 reference specimens (healthy community children and adolescents) from the CALIPER bio-bank, and all testing centers participated in an external quality assessment (EQA) evaluation. In general, the transferred pediatric reference intervals were similar to those established in our previous study. However, assay-specific differences in reference limits were observed for many analytes, and in some instances were considerable. The results of the EQA evaluation generally mimicked the similarities and differences in reference limits among the five manufacturers' assays. In addition, the majority of transferred reference intervals were validated through the analysis of CALIPER reference samples. This study greatly extends the utility of the CALIPER reference interval database which is now directly applicable for assays performed on five major analytical platforms in clinical use, and should permit the worldwide application of CALIPER pediatric reference intervals. Copyright © 2013 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  7. Direct nitrate reductase assay versus microscopic observation drug susceptibility test for rapid detection of MDR-TB in Uganda.

    Directory of Open Access Journals (Sweden)

    Freddie Bwanga

    Full Text Available The most common method for detection of drug resistant (DR TB in resource-limited settings (RLSs is indirect susceptibility testing on Lowenstein-Jensen medium (LJ which is very time consuming with results available only after 2-3 months. Effective therapy of DR TB is therefore markedly delayed and patients can transmit resistant strains. Rapid and accurate tests suitable for RLSs in the diagnosis of DR TB are thus highly needed. In this study we compared two direct techniques--Nitrate Reductase Assay (NRA and Microscopic Observation Drug Susceptibility (MODS for rapid detection of MDR-TB in a high burden RLS. The sensitivity, specificity, and proportion of interpretable results were studied. Smear positive sputum was collected from 245 consecutive re-treatment TB patients attending a TB clinic in Kampala, Uganda. Samples were processed at the national reference laboratory and tested for susceptibility to rifampicin and isoniazid with direct NRA, direct MODS and the indirect LJ proportion method as reference. A total of 229 specimens were confirmed as M. tuberculosis, of these interpretable results were obtained in 217 (95% with either the NRA or MODS. Sensitivity, specificity and kappa agreement for MDR-TB diagnosis was 97%, 98% and 0.93 with the NRA; and 87%, 95% and 0.78 with the MODS, respectively. The median time to results was 10, 7 and 64 days with NRA, MODS and the reference technique, respectively. The cost of laboratory supplies per sample was low, around 5 USD, for the rapid tests. The direct NRA and MODS offered rapid detection of resistance almost eight weeks earlier than with the reference method. In the study settings, the direct NRA was highly sensitive and specific. We consider it to have a strong potential for timely detection of MDR-TB in RLS.

  8. T2 Magnetic Resonance Assay-Based Direct Detection of Three Lyme Disease-Related Borrelia Species in Whole-Blood Samples.

    Science.gov (United States)

    Snyder, Jessica L; Giese, Heidi; Bandoski-Gralinski, Cheryl; Townsend, Jessica; Jacobson, Beck E; Shivers, Robert; Schotthoefer, Anna M; Fritsche, Thomas R; Green, Clayton; Callister, Steven M; Branda, John A; Lowery, Thomas J

    2017-08-01

    In early Lyme disease (LD), serologic testing is insensitive and seroreactivity may reflect active or past infection. In this study, we evaluated a novel assay for the direct detection of three species of Borrelia spirochetes in whole blood. The T2 magnetic resonance (T2MR) assay platform was used to amplify Borrelia DNA released from intact spirochetes and to detect amplicon. Analytical sensitivity was determined from blood spiked with known concentrations of spirochetes, and the assay's limit of detection was found to be in the single-cell-per-milliliter range: 5 cells/ml for B. afzelii and 8 cells/ml for Borrelia burgdorferi and Borrelia garinii Clinical samples ( n = 66) from confirmed or suspected early LD patients were also analyzed. B. burgdorferi was detected using T2MR in 2/2 (100%) of blood samples from patients with confirmed early LD, based on the presence of erythema migrans and documentation of seroconversion or a positive real-time blood PCR. T2MR detected B. burgdorferi in blood samples from 17/54 (31%) of patients with probable LD, based on the presence of erythema migrans without documented seroconversion or of documented seroconversion in patients with a compatible clinical syndrome but without erythema migrans. Out of 21 clinical samples tested by real-time PCR, only 1 was positive and 13 were negative with agreement with T2MR. An additional 7 samples that were negative by real-time PCR were positive with T2MR. Therefore, T2MR enables a low limit of detection (LoD) for Borrelia spp. in whole blood samples and is able to detect B. burgdorferi in clinical samples. Copyright © 2017 American Society for Microbiology.

  9. Valence States Modulation Strategy for Picomole Level Assay of Hg2+ in Drinking and Environmental Water by Directional Self-Assembly of Gold Nanorods.

    Science.gov (United States)

    Chen, Lu; Lu, Linlin; Wang, Sufan; Xia, Yunsheng

    2017-06-23

    In this study, we present a valence states modulation strategy for picomole level assay of Hg 2+ using directional self-assembly of gold nanorods (AuNRs) as signal readout. Hg 2+ ions are first controllably reduced to Hg + ions by appropriate ascorbic acid, and the reduced Hg + ions react with the tips of the preadded AuNRs and form gold amalgam. Such Hg + decorated AuNRs then end-to-end self-assemble into one-dimensional architectures by the bridging effects of lysine based on the high affinity of NH 2 -Hg + interactions. Correspondingly, the AuNRs' longitudinal surface plasmon resonance is gradually reduced and a new broad band appears at 900-1100 nm region simultaneously. The resulting distinctly ratiometric signal output is not only favorable for Hg 2+ ions detection but competent for their quantification. Under optimal conditions, the linear range is 22.8 pM to 11.4 nM, and the detection limit is as low as 8.7 pM. Various transition/heavy metal ions, such as Pb 2+ , Ti 2+ , Co 2+ , Fe 3+ , Mn 2+ , Ba 2+ , Fe 2+ , Ni 2+ , Al 3+ , Cu 2+ , Ag + , and Au 3+ , do not interfere with the assay. Because of ultrahigh sensitivity and excellent selectivity, the proposed system can be employed for assaying ultratrace of Hg 2+ containing in drinking and commonly environmental water samples, which is difficult to be achieved by conventional colorimetric systems. These results indicate that the present platform possesses specific advantages and potential applications in the assay of ultratrace amounts of Hg 2+ ions.

  10. Successful kidney transplantation across a positive complement-dependent cytotoxicity crossmatch by using C1q assay-directed, bortezomib-assisted desensitization: A case report.

    Science.gov (United States)

    Lee, Juhan; Park, Borae G; Jeong, Hyang Sook; Park, Youn Hee; Kim, Sinyoung; Kim, Beom Seok; Kim, Hye Jin; Huh, Kyu Ha; Jeong, Hyeon Joo; Kim, Yu Seun

    2017-09-01

    Human leukocyte antigen (HLA) is the major immunologic barrier in kidney transplantation (KT). Various desensitization protocols to overcome the HLA barrier have increased the opportunity for transplantation in sensitized patients. In addition, technological advances in solid-phase assays have permitted more comprehensive assessment of donor-specific antibodies. Although various desensitization therapies and immunologic techniques have been developed, the final transplantation decision is still based on the classic complement-dependent cytotoxicity (CDC) crossmatch (XM) technique. Some patients who fail to achieve negative XM have lost their transplant opportunities, even after receiving sufficient desensitization therapies. A 57-year-old male with end-stage renal disease secondary to chronic glomerulonephritis was scheduled to have a second transplant from his son, but CDC XM was positive. Initial CDC XM (Initial T-AHG 1:32) and flow-cytometry XM were positive. Anti-HLA-B59 donor specific antibody was detected by Luminex single antigen assay. Herein, we report a successful case of KT across a positive CDC XM (T-AHG 1:8 at the time of transplantation) by using C1q assay-directed, bortezomib-assisted desensitization. After confirming a negative conversion in the C1q donor-specific antibody, we decided to perform KT accepting a positive AHG-CDC XM of 1:8 at the time of transplantation. The posttransplant course was uneventful and a protocol biopsy at 3 months showed no evidence of rejection. The patient had excellent graft function at 12 months posttransplant. The results of XM test and solid-phase assay should be interpreted in the context of the individual patient.

  11. Extraction-less, rapid assay for the direct detection of 2,4,6-trichloroanisole (TCA) in cork samples.

    Science.gov (United States)

    Apostolou, Theofylaktos; Pascual, Nuria; Marco, M-Pilar; Moschos, Anastassios; Petropoulos, Anastassios; Kaltsas, Grigoris; Kintzios, Spyridon

    2014-07-01

    2,4,6-trichloroanisole (TCA), the cork taint molecule, has been the target of several analytical approaches over the few past years. In spite of the development of highly efficient and sensitive tools for its detection, ranging from advanced chromatography to biosensor-based techniques, a practical breakthrough for routine cork screening purposes has not yet been realized, in part due to the requirement of a lengthy extraction of TCA in organic solvents, mostly 12% ethanol and the high detectability required. In the present report, we present a modification of a previously reported biosensor system based on the measurement of the electric response of cultured fibroblast cells membrane-engineered with the pAb78 TCA-specific antibody. Samples were prepared by macerating cork tissue and mixing it directly with the cellular biorecognition elements, without any intervening extraction process. By using this novel approach, we were able to detect TCA in just five minutes at extremely low concentrations (down to 0.2 ppt). The novel biosensor offers a number of practical benefits, including a very considerable reduction in the total assay time by one day, and a full portability, enabling its direct employment for on-site, high throughput screening of cork in the field and production facilities, without requiring any type of supporting infrastructure. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Targeting Anti-Cancer Active Compounds: Affinity-Based Chromatographic Assays

    Science.gov (United States)

    de Moraes, Marcela Cristina; Cardoso, Carmen Lucia; Seidl, Claudia; Moaddel, Ruin; Cass, Quezia Bezerra

    2016-01-01

    Affinity-based chromatography assays encompass the use of solid supports containing immobilized biological targets to monitor binding events in the isolation , identification and/or characterization of bioactive compounds. This powerful bioanalytical technique allows the screening of potential binders through fast analyses that can be directly performed using isolated substances or complex matrices. An overview of the recent researches in frontal and zonal affinity-based chromatography screening assays, which has been used as a tool in the identification and characterization of new anti-cancer agents, is discussed. In addition, a critical evaluation of the recently emerged ligands fishing assays in complex mixtures is also discussed. PMID:27306095

  13. Development of a VHH-Based Erythropoietin Quantification Assay

    DEFF Research Database (Denmark)

    Kol, Stefan; Beuchert Kallehauge, Thomas; Adema, Simon

    2015-01-01

    Erythropoietin (EPO) quantification during cell line selection and bioreactor cultivation has traditionally been performed with ELISA or HPLC. As these techniques suffer from several drawbacks, we developed a novel EPO quantification assay. A camelid single-domain antibody fragment directed against...... human EPO was evaluated as a capturing antibody in a label-free biolayer interferometry-based quantification assay. Human recombinant EPO can be specifically detected in Chinese hamster ovary cell supernatants in a sensitive and pH-dependent manner. This method enables rapid and robust quantification...

  14. Assays of D-Amino Acid Oxidase Activity

    Directory of Open Access Journals (Sweden)

    Elena Rosini

    2018-01-01

    Full Text Available D-amino acid oxidase (DAAO is a well-known flavoenzyme that catalyzes the oxidative FAD-dependent deamination of D-amino acids. As a result of the absolute stereoselectivity and broad substrate specificity, microbial DAAOs have been employed as industrial biocatalysts in the production of semi-synthetic cephalosporins and enantiomerically pure amino acids. Moreover, in mammals, DAAO is present in specific brain areas and degrades D-serine, an endogenous coagonist of the N-methyl-D-aspartate receptors (NMDARs. Dysregulation of D-serine metabolism due to an altered DAAO functionality is related to pathological NMDARs dysfunctions such as in amyotrophic lateral sclerosis and schizophrenia. In this protocol paper, we describe a variety of direct assays based on the determination of molecular oxygen consumption, reduction of alternative electron acceptors, or α-keto acid production, of coupled assays to detect the hydrogen peroxide or the ammonium production, and an indirect assay of the α-keto acid production based on a chemical derivatization. These analytical assays allow the determination of DAAO activity both on recombinant enzyme preparations, in cells, and in tissue samples.

  15. Radioisotopic 51Cr-leukocyte adherence inhibition (LAI) assay. I

    International Nuclear Information System (INIS)

    Tsang, P.H.; Tangnavarad, K.; Lesnick, G.; Holland, J.F.; Bekesi, J.G.; Perloff, M.

    1980-01-01

    A simplified radioisotopic leukocyte adherence inhibition assay ( 51 Cr-LAI assay) was used to determine tumor-directed immune responses in patients with cancer of the breast. Essential steps in development of this assay are the standardization of conditions for optimal 51 Cr uptake by peripheral blood lymphocytes (PBL) and the inclusion of autologous or normal AB serum in the incubation media. A dextrose salt mixture (GNK) was found to enhance intracellular uptake of 51 Cr significantly (8-fold) without affecting viability of the cells or without causing selective loss of lymphocyte subpopulations. The presence of 10% autologous or normal AB serum prevented non-specific LAI responses to unrelated tumor antigens. Experimental results are presented and it is seen that this short term (4 h) 51 Cr-LAI assay provides reproducible and specific results analogous to those using tube-LAI assay. The test has the advantages of being accurate, sensitive and free from technical bias. (Auth.)

  16. Status of LSDS Development for Isotopic Fissile Assay in Used Fuel

    International Nuclear Information System (INIS)

    Lee, Y.D.; Ahn, S.; Kim, H.-D.; Song, K.C.; Park, C.J.

    2015-01-01

    Because of the large amount accumulation of spent fuel, a research to solve the spent fuel problem is actively performed in Korea. One option is to develop the SFR linked with the pyro process to reuse the existing fissile materials in spent fuel. Therefore, an accurate isotopic fissile content assay becomes a key factor in the reuse of fissile material for safety and safeguards purpose. There are several commercial non-destructive technologies for nuclear material assay. However, technology for direct isotopic fissile content assay in spent fuel is not developed yet. Internationally, a verification of special nuclear material in spent fuel, mainly U-235, Pu239, Pu241, is very important for the safeguards objective. These fissile materials can be misused for nuclear weapon purpose, not for peaceful use. As a future nuclear system is developed,, improved safeguards technology must be developed for an approval of fissile materials. A direct measurement of fissile materials is very important to provide a continuous of knowledge on nuclear materials. LSDS (Lead Slowing Down Spectrometer) has an advantage to assay an isotopic fissile content directly, without any help of burnup code and history. LSDS system is under development in KAERI (Korea Atomic Energy Research Institute) for spent fuel and recycled fuel. A linear assay model was setup for U235, Pu239 and Pu241. The dominant individual fission characteristic is appeared between 0.1 eV and 1 keV range. An electron linear accelerator for compact and low cost is under development to produce high source neutron effectively and efficiently. The LSDS is also applicable for optimum design of spent fuel storage and management. The advanced fissile assay technology will contribute to increase the transparency and credibility internationally on a reuse of fissile materials in future nuclear energy system development. (author)

  17. Multicenter Clinical Evaluation of the Alere i Respiratory Syncytial Virus Isothermal Nucleic Acid Amplification Assay.

    Science.gov (United States)

    Hassan, Ferdaus; Hays, Lindsay M; Bonner, Aleta; Bradford, Bradley J; Franklin, Ruffin; Hendry, Phyllis; Kaminetsky, Jed; Vaughn, Michael; Cieslak, Kristin; Moffatt, Mary E; Selvarangan, Rangaraj

    2018-03-01

    The Alere i respiratory syncytial virus (RSV) assay is an isothermal nucleic acid amplification test capable of detecting RSV directly from respiratory specimens, with results being available in ≤13 min after test initiation. The objective of this study was to evaluate the performance characteristics of the Alere i RSV assay in a point-of-care setting by using direct nasopharyngeal (NP) swab specimens (direct NP) and nasopharyngeal swab specimens eluted and transported in viral transport medium (VTM NP). The study was a prospective, multicenter, clinical trial conducted at 9 sites across the United States to evaluate the clinical performance of the Alere i RSV assay with respiratory specimens obtained from both children (age, 60 years). The performance of the Alere i RSV assay was compared with that of the reference method, the Prodesse ProFlu+ real-time reverse transcriptase PCR (RT-PCR) assay. All specimens with discrepant test results were tested further by a second FDA-cleared PCR assay (the Verigene respiratory virus plus nucleic acid test; Luminex Inc., TX). A total of 554 subjects with signs and symptoms of respiratory infections were enrolled, and respiratory samples were collected in this study. In comparison with the ProFlu+ real-time RT-PCR, the overall sensitivity and specificity of Alere i RSV assay for the detection of RSV were 98.6% (95% confidence interval [CI], 94.4 to 99.7%) and 98.0% (95% CI, 95.8 to 99.1%), respectively, for direct NP and 98.6% (95% CI, 94.4 to 99.7%) and 97.8% (95% CI, 95.5 to 98.9%), respectively, for VTM NP. The Alere i RSV is a highly sensitive and specific molecular assay ideal for rapid RSV detection in patients in the point-of-care setting due to its minimal hands-on time and rapid result availability. Copyright © 2018 American Society for Microbiology.

  18. Aptamer-Phage Reporters for Ultrasensitive Lateral Flow Assays.

    Science.gov (United States)

    Adhikari, Meena; Strych, Ulrich; Kim, Jinsu; Goux, Heather; Dhamane, Sagar; Poongavanam, Mohan-Vivekanandan; Hagström, Anna E V; Kourentzi, Katerina; Conrad, Jacinta C; Willson, Richard C

    2015-12-01

    We introduce the modification of bacteriophage particles with aptamers for use as bioanalytical reporters, and demonstrate the use of these particles in ultrasensitive lateral flow assays. M13 phage displaying an in vivo biotinylatable peptide (AviTag) genetically fused to the phage tail protein pIII were used as reporter particle scaffolds, with biotinylated aptamers attached via avidin-biotin linkages, and horseradish peroxidase (HRP) reporter enzymes covalently attached to the pVIII coat protein. These modified viral nanoparticles were used in immunochromatographic sandwich assays for the direct detection of IgE and of the penicillin-binding protein from Staphylococcus aureus (PBP2a). We also developed an additional lateral flow assay for IgE, in which the analyte is sandwiched between immobilized anti-IgE antibodies and aptamer-bearing reporter phage modified with HRP. The limit of detection of this LFA was 0.13 ng/mL IgE, ∼100 times lower than those of previously reported IgE assays.

  19. Evaluation of a new commercial assay for diagnosis of pulmonary and nonpulmonary tuberculosis

    DEFF Research Database (Denmark)

    Johansen, I S; Thomsen, V Ø; Johansen, A

    2002-01-01

    A new commercial assay for the diagnosis of tuberculosis, the BDProbeTec ET Direct Detection assay (Becton Dickinson, USA), was evaluated using 351 respiratory and 372 nonrespiratory specimens. The results were compared to detection of Mycobacterium tuberculosis complex (MTC) by conventional...

  20. Development of a monoclonal antibody-based, congener-specific and solvent-tolerable direct enzyme-linked immunosorbgent assay for the detection of 2,2',4,4'-tetrabromodiphenyl ether in environmental samples

    Science.gov (United States)

    A sensitive direct enzyme-linked immunosorbent assay (ELISA) for the detection of 2,2',4,4'-tetrabromodiphenyl ether (BDE-47) in environmental samples was developed. A hapten mimicking the whole structure of BDE-47 was synthesized by introducing a butyric acid spacer to 5-hydroxy-BDE-47 and coupled ...

  1. Anaerobic microplate assay for direct microbial conversion of switchgrass and Avicel using Clostridium thermocellum

    Energy Technology Data Exchange (ETDEWEB)

    Oguntimein, Gbekeloluwa B. [Morgan State Univ., Baltimore, MD (United States); Rodriguez, Jr., Miguel [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); National Lab., Oak Ridge, TN (United States). BioEnergy Science Center; Dumitrache, Alexandru [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); National Lab., Oak Ridge, TN (United States). BioEnergy Science Center; Shollenberger, Todd [National Renewable Energy Lab. (NREL), Golden, CO (United States); Decker, Stephen R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Davison, Brian H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); National Lab., Oak Ridge, TN (United States). BioEnergy Science Center; Brown, Steven D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); National Lab., Oak Ridge, TN (United States). BioEnergy Science Center; LanzaTech, Inc., Skokie, IL (United States)

    2017-11-09

    Here, to develop and prototype a high-throughput microplate assay to assess anaerobic microorganisms and lignocellulosic biomasses in a rapid, cost-effective screen for consolidated bioprocessing potential. Clostridium thermocellum parent Δhpt strain deconstructed Avicel to cellobiose, glucose, and generated lactic acid, formic acid, acetic acid and ethanol as fermentation products in titers and ratios similar to larger scale fermentations confirming the suitability of a plate-based method for C. thermocellum growth studies. C. thermocellum strain LL1210, with gene deletions in the key central metabolic pathways, produced higher ethanol titers in the Consolidated Bioprocessing (CBP) plate assay for both Avicel and switchgrass fermentations when compared to the Δhpt strain. A prototype microplate assay system is developed that will facilitate high-throughput bioprospecting for new lignocellulosic biomass types, genetic variants and new microbial strains for bioethanol production.

  2. Radioimmune assay of human platelet prostaglandin synthetase

    International Nuclear Information System (INIS)

    Roth, G.J.; Machuga, E.T.

    1982-01-01

    Normal platelet function depends, in part, on platelet PG synthesis. PG synthetase (cyclo-oxygenase) catalyzes the first step in PG synthesis, the formation of PGH 2 from arachidonic acid. Inhibition of the enzyme by ASA results in an abnormality in the platelet release reaction. Patients with pparent congenital abnormalities in the enzyme have been described, and the effects have been referred to as ''aspirin-like'' defects of the platelet function. These patients lack platelet PG synthetase activity, but the actual content of PG synthetase protein in these individuals' platelets is unknown. Therefore an RIA for human platelet PG synthetase would provide new information, useful in assessing the aspirin-like defects of platelet function. An RIA for human platelet PG synthetase is described. The assay utilizes a rabbit antibody directed against the enzyme and [ 125 I]-labelled sheep PG synthetase as antigen. The human platelet enzyme is assayed by its ability to inhibit precipitation of the [ 125 I]antigen. The assay is sensitive to 1 ng of enzyme. By the immune assay, human platelets contain approximately 1200 ng of PG synethetase protein per 1.5 mg of platelet protein (approximately 10 9 platelets). This content corresponds to 10,000 enzyme molecules per platelet. The assay provides a rapid and convenient assay for the human platelet enzyme, and it can be applied to the assessment of patients with apparent platelet PG synthetase (cyclo-oxygenase) deficiency

  3. Detection of radiation-induced apoptosis using the comet assay

    International Nuclear Information System (INIS)

    Wada, Seiichi; Kobayashi, Yasuhiko; Funayama, Tomoo; Yamamoto, Kazuo; Khoa, Tran Van; Natsuhori, Masahiro; Ito, Nobuhiko

    2003-01-01

    The electrophoresis pattern of apoptotic cells detected by the comet assay has a characteristic small head and spread tail. This image has been referred to as an apoptotic comet, but it has not been previously proven to be apoptotic cells by any direct method. In order to identify this image obtained by the comet assay as corresponding to an apoptotic cell, the frequency of appearance of apoptosis was examined using CHO-K1 and L5178Y cells which were exposed to gamma irradiation. As a method for detecting apoptosis, the terminal deoxynucleotidyl transferase mediated dUTP nick end labeling (TUNEL) assay was used. When the frequency of appearance of apoptotic cells following gamma irradiation was observed over a period of time, there was a significant increase in appearance of apoptosis when using the TUNEL assay. However, there was only a slight increase when using the comet assay. In order to verify the low frequency of appearance of apoptosis when using the comet assay, we attempted to use the TUNEL assay to satin the apoptotic comets detected in the comet assay. The apoptotic comets were TUNEL positive and the normal comets were TUNEL negative. This indicates that the apoptotic comets were formed from DNA fragments with 3'-hydroxy ends that are generated as cells undergo apoptosis. Therefore, it was understood that the characteristic pattern of apoptotic comets detected by the comet assay corresponds to cells undergoing apoptosis. (author)

  4. Identification of phlebotomine sandfly bloodmeals from Baringo District, Kenya, by direct enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Ngumbi, P M; Lawyer, P G; Johnson, R N; Kiilu, G; Asiago, C

    1992-10-01

    Direct enzyme-linked immunosorbent assay (ELISA) was used to identify the sources of bloodmeals in phlebotomine sandflies from Baringo District, Rift Valley Province, Kenya. Some bloodmeals had been stored for over 4 years before being analysed. Among 356 sandflies identified, 62.9% were Phlebotomus martini, 14.8% Sergentomyia antennatus, 10% S.schwetzi, 6% S.clydei, 1.9% S.adleri, 1.6% P.duboscqi, 1.4% S.africanus and 0.8% S.bedfordi. Out of 224 P.martini bloodmeals, host source was identified for 69. The order of host preference for P.martini was: goat 28.5%, rabbit 22.7%, human 8.9% and others 8.9%. Evidence of mixed feeding was shown by four species comprising sixteen specimens, twelve of which were P.martini. The most effective methods for trapping bloodfed P. martini were sticky paper traps in termite hills, followed by light-traps. Of the 224 P.martini trapped, 58.9% were collected with traps in termite hills, and 22.7% with light traps. Roles of the three most popular hosts for P.martini should be investigated to ascertain whether they act as reservoirs in the transmission of Leishmania donovani causing visceral leishmaniasis in Kenya.

  5. Comparison of Parasite Burden Using Real-Time Polymerase Chain Reaction Assay and Limiting Dilution Assay in Leishma-nia major Infected Mouse

    Directory of Open Access Journals (Sweden)

    Somayeh GHOTLOO

    2015-12-01

    Full Text Available Background:Limiting dilution assay is considered as the gold standard method for quantifying the number of parasites in the animal model of Leishmania infection. Nowadays, real-time PCR is being increasingly applied to quantify infectious agents. In the present study, a real-time PCR assay was developed to estimate para­site burdens in lymph nodes of Leishmania major infected BALB/C mice. Enumera­tion of parasites was also performed by limiting dilution assay and compared with the results of real-time PCR based quantification.Methods:The SYBR Green based real- time PCR assay was performed to amplify a 75 bp fragment of superoxide dismutase B1 gene in the lymph nodes of L. major infected BALB/C mice 8 weeks post infection. Mice were infected subcutaneously at the base of their tail with 2 × 105L. major promastigotes in the stationary phase of growth. To compare parasite burdens obtained by real-time PCR assay with those of limiting dilution assay, twelve 8-fold serial dilutions of the lymph node homoge­nates were prepared in the Schneider medium and incubated at 26°C.After 7 days, wells containing motile parasites were identified by direct observation under an inverted light microscope and the total number of parasites was estimated using the ELIDA software.Results:Spearman's correlation coefficient of the parasite burdens between real-time PCR and limiting dilution assay was 0.72 (Pvalue = 0.008.Conclusion:Real-time PCR assay is an appropriate replacement to existing limit­ing dilution assay in quantifying parasite burden in the experimental model of Leishma­nia infection.

  6. New aspects of radioimmunochemical measurement of human parathyroid hormone using the labelled antibody technique

    International Nuclear Information System (INIS)

    Hesch, R.D.; McIntosh, C.H.S.; Woodhead, J.S.; Welsh National School of Medicine, Cardiff

    1975-01-01

    Two forms of heterogeneity of parathyroid hormone (PTH) have given rise to conflicting results: one due to the heterogeneity of the secreted species from the gland and their peripheral metabolism and the other representing the immunochemical heterogeneity of the available antibodies. We have developed sequence specific assays using the technique of labelled antibodies. Therefore, results of assays measuring the C-terminal part and the (1-34)-N-terminal part of the molecule could be compared to those of an assay for hormone bearing both N- and C-terminal antigenic determinants. This assay is supposed to detect predominantly (1-84)-intact hormone. The immunoradiometric assay of (1-34)-PTH has a sensitivity of 0.04 ng/ml. This technique avoids the critical iodination of the hormone fragment containing no tyrosine. There is the expected overlap between normal subjects and patients with primary and secondary hyperparathyroidism. The most important finding are results from patients undergoing neck catheterization. We demonstrated nonuniform secretion of different species of PTH by parathyroid adenomata and normal glands. This supports the hypothesis of cleavage of the (1-84)-molecule in the gland. (orig.) [de

  7. Evaluation of Six Different Immunoassays for Serum Thyrotropin

    International Nuclear Information System (INIS)

    Ma Donghong; Lu Hankui; Gao Yunchao; Ge Wenli; Xiong Jiang; Liu Qiaoping; Gu Qing

    2010-01-01

    To analyzes the discrepancy and association among six different thyrotropin (TSH) immunoassay methods and to study their impact on the clinical diagnoses of thyroid diseases, the 150 serum samples from three groups consisting of hyperthyroidism, hypothyroidism and healthy subjects, 50 samples in each group were included in this study. The serum TSH levels were measured simultaneously by radioimmunoassay (RIA), immunoradiometric assay (IRMA), three-type chemilumiminescence immunoassay (CLIA) and electrochemiluminescence immunoassay (ECLIA). The results showed that individual serum TSH level varied significantly from one assay to another. There was no correlation between TSH RIA and other five assays in groups of hyperthyroidism and healthy subjects(P>0.05). The correlations between TSH IRMA and four automatic assays in hyperthyroidism group were relatively low (r= 0.38∼0.41). However, among the four automatic assays, TSH levels were well correlated (r= 0.92∼0.99). For clinical diagnoses, TSH RIA alone was not useful in the differentiation of hyperthyroidism and normal subjects, and TSH IRMA was misleading in some hyperthyroidism. There were no significant differences for four TSH automatic immunoassays in differential diagnoses of thyroid diseases. (authors)

  8. A locked nucleic acid (LNA-based real-time PCR assay for the rapid detection of multiple bacterial antibiotic resistance genes directly from positive blood culture.

    Directory of Open Access Journals (Sweden)

    Lingxiang Zhu

    Full Text Available Bacterial strains resistant to various antibiotic drugs are frequently encountered in clinical infections, and the rapid identification of drug-resistant strains is highly essential for clinical treatment. We developed a locked nucleic acid (LNA-based quantitative real-time PCR (LNA-qPCR method for the rapid detection of 13 antibiotic resistance genes and successfully used it to distinguish drug-resistant bacterial strains from positive blood culture samples. A sequence-specific primer-probe set was designed, and the specificity of the assays was assessed using 27 ATCC bacterial strains and 77 negative blood culture samples. No cross-reaction was identified among bacterial strains and in negative samples, indicating 100% specificity. The sensitivity of the assays was determined by spiking each bacterial strain into negative blood samples, and the detection limit was 1-10 colony forming units (CFU per reaction. The LNA-qPCR assays were first applied to 72 clinical bacterial isolates for the identification of known drug resistance genes, and the results were verified by the direct sequencing of PCR products. Finally, the LNA-qPCR assays were used for the detection in 47 positive blood culture samples, 19 of which (40.4% were positive for antibiotic resistance genes, showing 91.5% consistency with phenotypic susceptibility results. In conclusion, LNA-qPCR is a reliable method for the rapid detection of bacterial antibiotic resistance genes and can be used as a supplement to phenotypic susceptibility testing for the early detection of antimicrobial resistance to allow the selection of appropriate antimicrobial treatment and to prevent the spread of resistant isolates.

  9. Cryogenic gamma detectors enable direct detection of 236U and minor actinides for non-destructive assay

    International Nuclear Information System (INIS)

    Miguel Velazquez; Jonathan Dreyer; Drury, O.B.; Friedrich, Stephan; Saleem Salaymeh

    2016-01-01

    We demonstrate the utility of a superconducting transition edge sensor (TES) γ-ray detector with high energy resolution and low Compton background for nondestructive assay (NDA) of a uranium sample from reprocessed nuclear fuel. We show that TES γ-detectors can separate low-energy actinide γ-emissions from the background and nearby lines, even from minor isotopes whose signals are often obscured in NDA with conventional Ge detectors. Superconducting γ-detectors may therefore bridge the gap between high-accuracy destructive assay (DA) and easier-to-use NDA. (author)

  10. Comparison of a direct and indirect ELISA for quantitating antisperm antibody in semen.

    Science.gov (United States)

    Lynch, D M; Howe, S E

    1987-01-01

    A direct and an indirect quantitative ELISA for antisperm antibody were compared using the spermatozoa and cell-free seminal fluid of 66 infertile males. The normal concentration of sperm binding immunoglobulin was less than or equal to 1.5 fg Ig per spermatozoon for the indirect seminal plasma assay and less than or equal to 1.5 fg Ig per spermatozoon by the direct assay. Of the 66 infertile males, 21% (14/66) had elevated levels of antisperm antibody in their seminal plasma and 26% (17/66) had elevated levels bound directly to their spermatozoa. The direct correlation between the results of these assays was 94%. A simple linear regression analysis between the indirect and direct measurements of antisperm antibody resulted in a correlation coefficient of r = 0.907. There was no statistically significant difference between results from the direct and indirect methods of the patients as a group. However, there was evidence of autospecificity in a small percentage of males who had elevated levels of antisperm antibody by the direct assay that was not detected by the indirect assay using pooled donor spermatozoa.

  11. Development of an enzyme-linked immunosorbent assay method to detect mustard protein in mustard seed oil

    NARCIS (Netherlands)

    Koppelman, S.J.; Vlooswijk, R.; Bottger, G.; Duijn, G. van; Schaft, P. van der; Dekker, J.; Bemgen, H. van

    2007-01-01

    An enzyme-linked immunosorbent assay for the detection of mustard protein was developed. The assay is based on a polyclonal antiserum directed against a mixture of mustard proteins raised in rabbits. The assay has a detection limit of 1.5 ppm (milligrams per kilogram) and is suitable for the

  12. Testing human sperm chemotaxis: how to detect biased motion in population assays.

    Directory of Open Access Journals (Sweden)

    Leah Armon

    Full Text Available Biased motion of motile cells in a concentration gradient of a chemoattractant is frequently studied on the population level. This approach has been particularly employed in human sperm chemotactic assays, where the fraction of responsive cells is low and detection of biased motion depends on subtle differences. In these assays, statistical measures such as population odds ratios of swimming directions can be employed to infer chemotactic performance. Here, we report on an improved method to assess statistical significance of experimentally determined odds ratios and discuss the strong impact of data correlations that arise from the directional persistence of sperm swimming.

  13. LDLCHOLESTEROLEXAMINATION (LDL-C USINGHOMOGENEOUS ASSAY

    Directory of Open Access Journals (Sweden)

    Made DwiAmbara Putra

    2013-07-01

    Full Text Available Homogeneous method describe as a method that does not require separation of free and bound label. This method has the ability tofully automate the determination of LDL-C directly small sample volume sand short examination time. In addition this method use automated pipette and control of time and temperature more accurate. There are 5 methods i.e. Solubilization homogeneous LDL-C assay (SOL from KyowaMedex, Surfactant LDL-C assay (SUR from Daiichi Pure Chemicals, Protecting LDL-assay reagent (PRO from Wako Chemicals, LDL-C assaycatalase (CAT Denka Seiken and Calixarene of LDL-C assay (CAL from International Reagents Corporation. All method is to use a variety of detergents and other chemicals that cause blocking or dissolution of specific lipoprotein classes to achieve specificity for LDL. Normal 0 false false false EN-US X-NONE X-NONE /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  14. A Compton Suppressed Gamma Ray Counter For Radio Assay of Materials

    Science.gov (United States)

    Godfrey, Benjamin

    2016-03-01

    Rare event searches, such as direct dark matter experiments, require materials with ultra-low levels of natural radioactivity. We present a neutron activation analysis (NAA) technique for assaying metals, specifically titanium used for cryostat construction. Earlier attempts at NAA encountered limitations due to bulk activation via (n, p) reactions, which contributed to large continuum backgrounds due to Compton tails. Our method involves a heavy water shielded exposure to minimize (n,p) reactions and a sodium iodide shielded high purity germanium counter for the gamma ray assay. Preliminary results on assays for U/Th/K contamination in titaniumwill be presented.

  15. Evaluation of a next generation direct whole blood enzymatic assay for hemoglobin A1c on the ARCHITECT c8000 chemistry system.

    Science.gov (United States)

    Teodoro-Morrison, Tracy; Janssen, Marcel J W; Mols, Jasper; Hendrickx, Ben H E; Velmans, Mathieu H; Lotz, Johannes; Lackner, Karl; Lennartz, Lieselotte; Armbruster, David; Maine, Gregory; Yip, Paul M

    2015-01-01

    The utility of HbA1c for the diagnosis of type 2 diabetes requires an accurate, precise and robust test measurement system. Currently, immunoassay and HPLC are the most popular methods for HbA1c quantification, noting however the limitations associated with some platforms, such as imprecision or interference from common hemoglobin variants. Abbott Diagnostics has introduced a fully automated direct enzymatic method for the quantification of HbA1c from whole blood on the ARCHITECT chemistry system. Here we completed a method evaluation of the ARCHITECT HbA1c enzymatic assay for imprecision, accuracy, method comparison, interference from hemoglobin variants and specimen stability. This was completed at three independent clinical laboratories in North America and Europe. The total imprecision ranged from 0.5% to 2.2% CV with low and high level control materials. Around the diagnostic cut-off of 48 mmol/mol, the total imprecision was 0.6% CV. Mean bias using reference samples from IFCC and CAP ranged from -1.1 to 1.0 mmol/mol. The enzymatic assay also showed excellent agreement with HPLC methods, with slopes of 1.01 and correlation coefficients ranging from 0.984 to 0.996 compared to Menarini Adams HA-8160, Bio-Rad Variant II and Variant II Turbo instruments. Finally, no significant effect was observed for erythrocyte sedimentation or interference from common hemoglobin variants in patient samples containing heterozygous HbS, HbC, HbD, HbE, and up to 10% HbF. The ARCHITECT enzymatic assay for HbA1c is a robust and fully automated method that meets the performance requirements to support the diagnosis of type 2 diabetes.

  16. Assaying Cellular Viability Using the Neutral Red Uptake Assay.

    Science.gov (United States)

    Ates, Gamze; Vanhaecke, Tamara; Rogiers, Vera; Rodrigues, Robim M

    2017-01-01

    The neutral red uptake assay is a cell viability assay that allows in vitro quantification of xenobiotic-induced cytotoxicity. The assay relies on the ability of living cells to incorporate and bind neutral red, a weak cationic dye, in lysosomes. As such, cytotoxicity is expressed as a concentration-dependent reduction of the uptake of neutral red after exposure to the xenobiotic under investigation. The neutral red uptake assay is mainly used for hazard assessment in in vitro toxicology applications. This method has also been introduced in regulatory recommendations as part of 3T3-NRU-phototoxicity-assay, which was regulatory accepted in all EU member states in 2000 and in the OECD member states in 2004 as a test guideline (TG 432). The present protocol describes the neutral red uptake assay using the human hepatoma cell line HepG2, which is often employed as an alternative in vitro model for human hepatocytes. As an example, the cytotoxicity of acetaminophen and acetyl salicylic acid is assessed.

  17. Development of a direct species-specific PCR assay for differential diagnosis of Leishmania tropica

    Czech Academy of Sciences Publication Activity Database

    Jirků, Milan; Zemanová, Eva; Al-Jawabreh, A.; Schönian, G.; Lukeš, Julius

    2006-01-01

    Roč. 55, č. 1 (2006), s. 75-79 ISSN 0732-8893 Grant - others:European Comission(EU) QLK2-CT-2001-01810 Institutional research plan: CEZ:AV0Z60220518 Keywords : Kinetoplastida * Leishmania tropica * PCR assay Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 2.553, year: 2006

  18. The loss-of-allele assay for ES cell screening and mouse genotyping.

    Science.gov (United States)

    Frendewey, David; Chernomorsky, Rostislav; Esau, Lakeisha; Om, Jinsop; Xue, Yingzi; Murphy, Andrew J; Yancopoulos, George D; Valenzuela, David M

    2010-01-01

    Targeting vectors used to create directed mutations in mouse embryonic stem (ES) cells consist, in their simplest form, of a gene for drug selection flanked by mouse genomic sequences, the so-called homology arms that promote site-directed homologous recombination between the vector and the target gene. The VelociGene method for the creation of targeted mutations in ES cells employs targeting vectors, called BACVecs, that are based on bacterial artificial chromosomes. Compared with conventional short targeting vectors, BacVecs provide two major advantages: (1) their much larger homology arms promote high targeting efficiencies without the need for isogenicity or negative selection strategies; and (2) they enable deletions and insertions of up to 100kb in a single targeting event, making possible gene-ablating definitive null alleles and other large-scale genomic modifications. Because of their large arm sizes, however, BACVecs do not permit screening by conventional assays, such as long-range PCR or Southern blotting, that link the inserted targeting vector to the targeted locus. To exploit the advantages of BACVecs for gene targeting, we inverted the conventional screening logic in developing the loss-of-allele (LOA) assay, which quantifies the number of copies of the native locus to which the mutation was directed. In a correctly targeted ES cell clone, the LOA assay detects one of the two native alleles (for genes not on the X or Y chromosome), the other allele being disrupted by the targeted modification. We apply the same principle in reverse as a gain-of-allele assay to quantify the copy number of the inserted targeting vector. The LOA assay reveals a correctly targeted clone as having lost one copy of the native target gene and gained one copy of the drug resistance gene or other inserted marker. The combination of these quantitative assays makes LOA genotyping unequivocal and amenable to automated scoring. We use the quantitative polymerase chain reaction

  19. Matrix effects of TRU [transuranic] assays using the SWEPP PAN assay system

    International Nuclear Information System (INIS)

    Smith, J.R.

    1990-08-01

    The Drum Assay System (DAS) at the Stored Waste Experimental Pilot Plant (SWEPP) is a second-generation active-passive neutron assay system. It has been used to assay over 5000 208-liter drums of transuranic waste from the Rocky Flats Plant (RFP). Data from these assays have been examined and compared with the assays performed at Rocky Flats, mainly utilize counting of 239 Pu gamma rays. For the most part the passive assays are in very good agreement with the Rocky Flats assays. The active assays are strongly correlated with the results of the other two methods, but require matrix-dependent correction factors beyond those provided by the system itself. A set of matrix-dependent correction factors has been developed from the study of the assay results. 3 refs., 4 figs., 3 tabs

  20. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo [Seoul National University college of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2+-1.7%, 3.9+-2.1%, 7.1+-6.2%, 11.2+-7.2%. The CVs by random assay were 2.1+-1.7%, 4.8+-3.1%, 3.6+-4.8%, and 7.4+-6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  1. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo

    2009-01-01

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2±1.7%, 3.9±2.1%, 7.1±6.2%, 11.2±7.2%. The CVs by random assay were 2.1±1.7%, 4.8±3.1%, 3.6±4.8%, and 7.4±6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  2. Agarose gel shift assay reveals that calreticulin favors substrates with a quaternary structure in solution

    DEFF Research Database (Denmark)

    Boelt, Sanne Grundvad; Houen, Gunnar; Højrup, Peter

    2015-01-01

    Here we present an agarose gel shift assay that, in contrast to other electrophoresis approaches, is loaded in the center of the gel. This allows proteins to migrate in either direction according to their isoelectric points. Therefore, the presented assay enables a direct visualization, separation...... structure. It is also demonstrated that the agarose gel shift assay is useful in the study of other protein interactions and can be used as an alternative method to native polyacrylamide gel electrophoresis....... measure of interactions. Therefore, no interaction studies between calreticulin and substrates in solution have been investigated previously. The results presented here indicate that calreticulin has a preference for substrates with a quaternary structure and primarily β-sheets in their secondary...

  3. Radioreceptor opioid assay

    International Nuclear Information System (INIS)

    Miller, R.J.; Chang, K.-J.

    1981-01-01

    A radioreceptor assay is described for assaying opioid drugs in biological fluids. The method enables the assay of total opioid activity, being specific for opioids as a class but lacking specificity within the class. A radio-iodinated opioid and the liquid test sample are incubated with an opiate receptor material. The percentage inhibition of the binding of the radio-iodinated compound to the opiate receptor is calculated and the opioid activity of the test liquid determined from a standard curve. Examples of preparing radio-iodinated opioids and assaying opioid activity are given. A test kit for the assay is described. Compared to other methods, this assay is cheap, easy and rapid. (U.K.)

  4. Evaluation of a new free-thyroxin assay

    International Nuclear Information System (INIS)

    Welby, M.L.; Guthrie, L.; Reilly, C.P.

    1981-01-01

    The Amerlex Free Thyroxin (T 4 ) Radioimmunoassay Kit (Amersham International Ltd.) is a new direct equilibrium radioimmunoassay for free T 4 based on an antiserum with very high affinity for T 4 , and a unique 125 l-labeled T 4 analog as tracer. It is a very simple single-tube radioimmunoassay, making use of Amerlex particles to separate antibody-bound from free species. Interassay precision (CV) is 3.7% at 13 pmol/L and 2.3% at 30 pmol/L; within-assay precision is 4.2% at 21 pmol/L. The reference interval is 11-22 pmol/L. The assay did not misclassify any patients tested who had untreated myxedema or untreated thyrotoxicosis. The free T 4 assay excelled both the free T 4 index and the T 4 /T 4 -binding globulin ratio in correcting for increased thyroxin-binding globulin from pregnancy, and it was better than the index but not better than the ratio in correcting for increased thyroxin-binding globulin in users of oral contraceptives

  5. Profiling the HER3/PI3K Pathway in Breast Tumors Using Proximity-Directed Assays Identifies Correlations between Protein Complexes and Phosphoproteins

    Science.gov (United States)

    Mukherjee, Ali; Badal, Youssouf; Nguyen, Xuan-Thao; Miller, Johanna; Chenna, Ahmed; Tahir, Hasan; Newton, Alicia; Parry, Gordon; Williams, Stephen

    2011-01-01

    Background The identification of patients for targeted antineoplastic therapies requires accurate measurement of therapeutic targets and associated signaling complexes. HER3 signaling through heterodimerization is an important growth-promoting mechanism in several tumor types and may be a principal resistance mechanism by which EGFR and HER2 expressing tumors elude targeted therapies. Current methods that can study these interactions are inadequate for formalin-fixed, paraffin-embedded (FFPE) tumor samples. Methodology and Principal Findings Herein, we describe a panel of proximity-directed assays capable of measuring protein-interactions and phosphorylation in FFPE samples in the HER3/PI3K/Akt pathway and examine the capability of these assays to inform on the functional state of the pathway. We used FFPE breast cancer cell line and tumor models for this study. In breast cancer cell lines we observe both ligand-dependent and independent activation of the pathway and strong correlations between measured activation of key analytes. When selected cell lines are treated with HER2 inhibitors, we not only observe the expected molecular effects based on mechanism of action knowledge, but also novel effects of HER2 inhibition on key targets in the HER receptor pathway. Significantly, in a xenograft model of delayed tumor fixation, HER3 phosphorylation is unstable, while alternate measures of pathway activation, such as formation of the HER3PI3K complex is preserved. Measurements in breast tumor samples showed correlations between HER3 phosphorylation and receptor interactions, obviating the need to use phosphorylation as a surrogate for HER3 activation. Significance This assay system is capable of quantitatively measuring therapeutically relevant responses and enables molecular profiling of receptor networks in both preclinical and tumor models. PMID:21297994

  6. Monte carlo feasibility study of an active neutron assay technique for full-volume UF{sub 6} cylinder assay using a correlated interrogation source

    Energy Technology Data Exchange (ETDEWEB)

    Miller, Karen A., E-mail: kamiller@lanl.gov [Los Alamos National Laboratory, Los Alamos, P.O. Box 1663 MS E540, NM 87545 (United States); Menlove, Howard O.; Swinhoe, Martyn T.; Marlow, Johnna B. [Los Alamos National Laboratory, Los Alamos, P.O. Box 1663 MS E540, NM 87545 (United States)

    2013-03-01

    Uranium cylinder assay plays an important role in the nuclear material accounting at gas centrifuge enrichment plants. The Passive Neutron Enrichment Meter (PNEM) was designed to determine uranium mass and enrichment in 30B and 48Y cylinders using total neutron and coincidence counting in the passive mode. 30B and 48Y cylinders are used to hold bulk UF{sub 6} feed, product, and tails at enrichment plants. In this paper, we report the results of a Monte-Carlo-based feasibility study for an active uranium cylinder assay system based on the PNEM design. There are many advantages of the active technique such as a shortened count time and a more direct measure of {sup 235}U content. The active system is based on a modified PNEM design and uses a {sup 252}Cf source as the correlated, active interrogation source. We show through comparison with a random AmLi source of equal strength how the use of a correlated driver significantly boosts the active signal and reduces the statistical uncertainty. We also discuss ways in which an active uranium cylinder assay system can be optimized to minimize background from {sup 238}U fast-neutron induced fission and direct counts from the interrogation source.

  7. New simple spectrophotometric assay of total carotenes in margarines

    NARCIS (Netherlands)

    Luterotti, S.; Bicanic, D.D.; Pozgaj, R.

    2006-01-01

    Direct and reliable spectrophotometric method for assaying total carotenes (TC) in margarines with the minimum of sample manipulation is proposed. For the first time saponification step used in determination of carotenes in margarines was omitted leading to a substantial cost saving and reduction of

  8. Specific and straightforward molecular investigation of β-thalassemia mutations in the Malaysian Malays and Chinese using direct TaqMan genotyping assays.

    Science.gov (United States)

    Kho, S L; Chua, K H; George, E; Tan, J A M A

    2013-07-15

    Beta-thalassemia is a life-threatening inherited blood disorder. Rapid characterization of β-globin gene mutations is necessary because of the high frequency of Malaysian β-thalassemia carriers. A combination real-time polymerase chain reaction genotyping assay using TaqMan probes was developed to confirm β-globin gene mutations. In this study, primers and probes were designed to specifically identify 8 common β-thalassemia mutations in the Malaysian Malay and Chinese ethnic groups using the Primer Express software. "Blind tests" using DNA samples from healthy individuals and β-thalassemia patients with different genotypes were performed to determine the specificity and sensitivity of this newly designed assay. Our results showed 100% sensitivity and specificity for this novel assay. In conclusion, the TaqMan genotyping assay is a straightforward assay that allows detection of β-globin gene mutations in less than 40 min. The simplicity and reproducibility of the TaqMan genotyping assay permit its use in laboratories as a rapid and cost-effective diagnostic tool for confirmation of common β-thalassemia mutations in Malaysia.

  9. Multiplexed lateral flow microarray assay for detection of citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis pv citri

    Energy Technology Data Exchange (ETDEWEB)

    Cary,; Bruce, R [Santa Fe, NM; Stubben, Christopher J [Los Alamos, NM

    2011-03-22

    The invention provides highly sensitive and specific assays for the major citrus pathogens Xylella fastidiosa and Xanthomonas axonopodis, including a field deployable multiplexed assay capable of rapidly assaying for both pathogens simultaneously. The assays are directed at particular gene targets derived from pathogenic strains that specifically cause the major citrus diseases of citrus variegated chlorosis (Xylella fastidiosa 9a5c) and citrus canker (Xanthomonas axonopodis pv citri). The citrus pathogen assays of the invention offer femtomole sensitivity, excellent linear dynamic range, and rapid and specific detection.

  10. Direct replacement of antibodies with molecularly imprinted polymer nanoparticles in ELISA--development of a novel assay for vancomycin.

    Science.gov (United States)

    Chianella, Iva; Guerreiro, Antonio; Moczko, Ewa; Caygill, J Sarah; Piletska, Elena V; De Vargas Sansalvador, Isabel M Perez; Whitcombe, Michael J; Piletsky, Sergey A

    2013-09-03

    A simple and straightforward technique for coating microplate wells with molecularly imprinted polymer nanoparticles (nanoMIPs) to develop assays similar to the enzyme-linked immunosorbent assay (ELISA) is presented here for the first time. NanoMIPs were synthesized by a solid-phase approach with an immobilized vancomycin (template) and characterized using Biacore 3000, dynamic light scattering, and electron microscopy. Immobilization, blocking, and washing conditions were optimized in microplate format. The detection of vancomycin was achieved in competitive binding experiments with a horseradish peroxidase-vancomycin conjugate. The assay was capable of measuring vancomycin in buffer and in blood plasma within the range of 0.001-70 nM with a detection limit of 0.0025 nM (2.5 pM). The sensitivity of the assay was 3 orders of magnitude better than a previously described ELISA based on antibodies. In these experiments, nanoMIPs have shown high affinity and minimal interference from blood plasma components. Immobilized nanoMIPs were stored for 1 month at room temperature without any detrimental effects to their binding properties. The high affinity of nanoMIPs and the lack of a requirement for cold chain logistics make them an attractive alternative to traditional antibodies used in ELISA.

  11. Selection of non-destructive assay methods: Neutron counting or calorimetric assay?

    International Nuclear Information System (INIS)

    Cremers, T.L.; Wachter, J.R.

    1994-01-01

    The transition of DOE facilities from production to D ampersand D has lead to more measurements of product, waste, scrap, and other less attractive materials. Some of these materials are difficult to analyze by either neutron counting or calorimetric assay. To determine the most efficacious analysis method, variety of materials, impure salts and hydrofluorination residues have been assayed by both calorimetric assay and neutron counting. New data will be presented together with a review of published data. The precision and accuracy of these measurements are compared to chemistry values and are reported. The contribution of the gamma ray isotopic determination measurement to the overall error of the calorimetric assay or neutron assay is examined and discussed. Other factors affecting selection of the most appropriate non-destructive assay method are listed and considered

  12. A quantitative and direct PCR assay for the subspecies-specific detection of Clavibacter michiganensis subsp. michiganensis based on a ferredoxin reductase gene.

    Science.gov (United States)

    Cho, Min Seok; Lee, Jang Ha; Her, Nam Han; Kim, Changkug; Seol, Young-Joo; Hahn, Jang Ho; Baeg, Ji Hyoun; Kim, Hong Gi; Park, Dong Suk

    2012-06-01

    The Gram-positive bacterium Clavibacter michiganensis subsp. michiganensis is the causal agent of canker disease in tomato. Because it is very important to control newly introduced inoculum sources from commercial materials, the specific detection of this pathogen in seeds and seedlings is essential for effective disease control. In this study, a novel and efficient assay for the detection and quantitation of C. michiganensis subsp. michiganensis in symptomless tomato and red pepper seeds was developed. A pair of polymerase chain reaction (PCR) primers (Cmm141F/R) was designed to amplify a specific 141 bp fragment on the basis of a ferredoxin reductase gene of C. michiganensis subsp. michiganensis NCPPB 382. The specificity of the primer set was evaluated using purified DNA from 16 isolates of five C. michiganensis subspecies, one other Clavibacter species, and 17 other reference bacteria. The primer set amplified a single band of expected size from the genomic DNA obtained from the C. michiganensis subsp. michiganensis strains but not from the other C. michiganensis subspecies or from other Clavibacter species. The detection limit was a single cloned copy of the ferredoxin reductase gene of C. michiganensis subsp. michiganensis. In conclusion, this quantitative direct PCR assay can be applied as a practical diagnostic method for epidemiological research and the sanitary management of seeds and seedlings with a low level or latent infection of C. michiganensis subsp. michiganensis.

  13. A Direct, Competitive Enzyme-Linked Immunosorbent Assay (ELISA) as a Quantitative Technique for Small Molecules

    Science.gov (United States)

    Powers, Jennifer L.; Rippe, Karen Duda; Imarhia, Kelly; Swift, Aileen; Scholten, Melanie; Islam, Naina

    2012-01-01

    ELISA (enzyme-linked immunosorbent assay) is a widely used technique with applications in disease diagnosis, detection of contaminated foods, and screening for drugs of abuse or environmental contaminants. However, published protocols with a focus on quantitative detection of small molecules designed for teaching laboratories are limited. A…

  14. Correlation between the genotoxicity endpoints measured by two different genotoxicity assays: comet assay and CBMN assay

    Directory of Open Access Journals (Sweden)

    Carina Ladeira

    2015-06-01

    The results concerning of positive findings by micronuclei and non significant ones by comet assay, are corroborated by Deng et al. (2005 study performed in workers occupationally exposed to methotrexate, also a cytostatic drug. According to Cavallo et al. (2009, the comet assay seems to be more suitable for the prompt evaluation of the genotoxic effects, for instance, of polycyclic aromatic hydrocarbons mixtures containing volatile substances, whereas the micronucleus test seems more appropriate to evaluate the effects of exposure to antineoplastic agents. However, there are studies that observed an increase in both the comet assay and the micronucleus test in nurses handling antineoplastic drugs, although statistical significance was only seen in the comet assay, quite the opposite of our results (Maluf & Erdtmann, 2000; Laffon et al. 2005.

  15. Application of the Single Cell Gel Electrophoresis (SCGE) Assay to Genotoxicity Evaluation in Plants and Animals

    International Nuclear Information System (INIS)

    Kim, Jin Kyu

    2007-10-01

    Application of the Single Cell Gel Electrophoresis (SCGE) Assay to Genotoxicity Evaluation in Plants and Animals. Recently, the importance of ionizing radiation and chemicals has been recognized since radio- and chemical therapy is directly related to the control of various diseases such as cancer. Radiation and the chemicals can cause biological damages while they have great applicability. It is of necessity to analyze rapidly, easily and accurately the biological effects, especially DNA damage due to those factors. Recently SCGE (single cell gel electrophoresis assay, alias comet assay) has been developed for the efficient evaluation of DNA damage. In this report, the comprehensive review will be given on the rationale, the technical applications and the advantages and shortcomings of SCGE assay. This method can be directly applied to study on toxicity, cancer, and aging in terms of the evaluation of DNA damages due to radiation and chemicals on human cellular level. It is also suggested that comet assay be used for testing genotoxicity of suspected substances, detecting irradiated foods, screening radioprotective candidates, and studying DNA repair process in various biological systems

  16. Application of the Single Cell Gel Electrophoresis (SCGE) Assay to Genotoxicity Evaluation in Plants and Animals

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Kyu

    2007-10-15

    Application of the Single Cell Gel Electrophoresis (SCGE) Assay to Genotoxicity Evaluation in Plants and Animals. Recently, the importance of ionizing radiation and chemicals has been recognized since radio- and chemical therapy is directly related to the control of various diseases such as cancer. Radiation and the chemicals can cause biological damages while they have great applicability. It is of necessity to analyze rapidly, easily and accurately the biological effects, especially DNA damage due to those factors. Recently SCGE (single cell gel electrophoresis assay, alias comet assay) has been developed for the efficient evaluation of DNA damage. In this report, the comprehensive review will be given on the rationale, the technical applications and the advantages and shortcomings of SCGE assay. This method can be directly applied to study on toxicity, cancer, and aging in terms of the evaluation of DNA damages due to radiation and chemicals on human cellular level. It is also suggested that comet assay be used for testing genotoxicity of suspected substances, detecting irradiated foods, screening radioprotective candidates, and studying DNA repair process in various biological systems.

  17. Fluorescence in situ hybridization in combination with the comet assay and micronucleus test in genetic toxicology

    Directory of Open Access Journals (Sweden)

    Hovhannisyan Galina G

    2010-09-01

    Full Text Available Abstract Comet assay and micronucleus (MN test are widely applied in genotoxicity testing and biomonitoring. While comet assay permits to measure direct DNA-strand breaking capacity of a tested agent MN test allows estimating the induced amount of chromosome and/or genome mutations. The potential of these two methods can be enhanced by the combination with fluorescence in situ hybridization (FISH techniques. FISH plus comet assay allows the recognition of targets of DNA damage and repairing directly. FISH combined with MN test is able to characterize the occurrence of different chromosomes in MN and to identify potential chromosomal targets of mutagenic substances. Thus, combination of FISH with the comet assay or MN test proved to be promising techniques for evaluation of the distribution of DNA and chromosome damage in the entire genome of individual cells. FISH technique also permits to study comet and MN formation, necessary for correct application of these methods. This paper reviews the relevant literature on advantages and limitations of Comet-FISH and MN-FISH assays application in genetic toxicology.

  18. A High-Throughput Assay for Rho Guanine Nucleotide Exchange Factors Based on the Transcreener GDP Assay.

    Science.gov (United States)

    Reichman, Melvin; Schabdach, Amanda; Kumar, Meera; Zielinski, Tom; Donover, Preston S; Laury-Kleintop, Lisa D; Lowery, Robert G

    2015-12-01

    Ras homologous (Rho) family GTPases act as molecular switches controlling cell growth, movement, and gene expression by cycling between inactive guanosine diphosphate (GDP)- and active guanosine triphosphate (GTP)-bound conformations. Guanine nucleotide exchange factors (GEFs) positively regulate Rho GTPases by accelerating GDP dissociation to allow formation of the active, GTP-bound complex. Rho proteins are directly involved in cancer pathways, especially cell migration and invasion, and inhibiting GEFs holds potential as a therapeutic strategy to diminish Rho-dependent oncogenesis. Methods for measuring GEF activity suitable for high-throughput screening (HTS) are limited. We developed a simple, generic biochemical assay method for measuring GEF activity based on the fact that GDP dissociation is generally the rate-limiting step in the Rho GTPase catalytic cycle, and thus addition of a GEF causes an increase in steady-state GTPase activity. We used the Transcreener GDP Assay, which relies on selective immunodetection of GDP, to measure the GEF-dependent stimulation of steady-state GTP hydrolysis by small GTPases using Dbs (Dbl's big sister) as a GEF for Cdc42, RhoA, and RhoB. The assay is well suited for HTS, with a homogenous format and far red fluorescence polarization (FP) readout, and it should be broadly applicable to diverse Rho GEF/GTPase pairs. © 2015 Society for Laboratory Automation and Screening.

  19. Development of a Waste Vault Directional Assay System (VDAS)

    Energy Technology Data Exchange (ETDEWEB)

    LaFleur, Adrienne Marie [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-11-08

    We are developing a portable neutron and gamma detector called VDAS with sufficient sensitivity and directional capability such that it could operate in high gamma dose rate environments. This detector will be designed such that it can be remotely deployed and adaptable to a broad range of possible facility infrastructure to record a 3D array of gross neutron and gamma measurements, including axial and radial rotation, for identifying potential SNM material locations.

  20. Radiological diagnosis of renal osteodystrophy with reference to clinical features in patients undergoing maintenance hemodialysis

    International Nuclear Information System (INIS)

    Huebsch, P.; Trattnig, S.; Barton, P.; Seidl, G.

    1989-01-01

    Pathophysiological, histological and radiological findings in renal osteodystrophy are described. Special emphasis is laid on secondary hyperparathyroidism. Preliminary results of the authors' investigations show a good correlation between radiological findings in the phalanges of the hand and the concentration of parathyroid hormone (PTH) in 14 patients. The concentration of the hormone in the blood was measured by a new 'two-site' immunoradiometric assay, which is specific for the intact, biologically active hormone. Patients with high concentrations of PTH in the blood tended to have more severe radiological changes. In 4 patients for whom radiographs of the hands revealed no pathologic findings, normal PTH concentrations in the blood were measured by this method, whereas the conventional assay gave elevated hormone concentrations for the same patients. This is due to the lack of specificity of the conventional method for the intact, biologically active hormone. Nevertheless, further investigations are needed to confirm these findings. (orig.) [de

  1. Determination of serum neuron specific enolase and glutathion S transferases levels in patients with acute cerebral infarction and its clinical significance

    International Nuclear Information System (INIS)

    Guo Jianyi; Lu Tianhe; Bao Yanmei

    2002-01-01

    Objective: To evaluate the variation of serum neuron specific enolase (NSE) and glutathion S transferases (GST) levels in patients with cerebral infarction and its clinical significance. Methods: The serum levels of NSE in cerebral infarction patients were determined with immunoradiometric assay (IRMA), and the serum level of GST were determined by enzyme immuno sandwich assay (ELISA). Results: Serum NSE levels linked in patients were significantly higher (p<0.01) and GST serum levels were significantly lower (p < 0.01) within 3 days after onset of disease than those at two weeks and those in the controls. There was a positive correlation between serum NSE levels and neurological deficit scores (p < 0.001) and a negative correlation with serum GST levels (p < 0.05). There was also a close relationship between the serum NSE levels and the volume of infarction (p < 0.001). Conclusion: There was a close relationship between the Serum levels of NSE, GST and clinical features of Patients in the early stage of cerebral infarction

  2. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  3. Evaluation of thyroid function tests in non-thyroidal illness

    International Nuclear Information System (INIS)

    Schutte, D.P.

    1988-01-01

    Normal thyroid physiology and pathophysiology with reference to non-thyroidal illness (NTI) is reviewed including specific disease states and drugs and their effect on thyroid function tests. The diagnostic utility of two new highly sensitive thyrotrophin (TSH) assays as screening tests for thyroid dysfunction are evaluated and compared with conventional thyroid function assays. A group of 40 patients with NTI was studied. This group was compared to a group of normal controls and a group of thyrotoxic patients. Conventional thyroid function tests yielded many values outside the reference range in the NTI group. The general pattern that emerged was decreased total triiodothyronine levels in 70% of NTI patients, normal to low thyroxine values, increased mean free thyroxine values (dialysis), low mean values for the free thyroxine index and varying results for newer commercial assays for free thyroxine according to methodology. The TSH response to intravenous thyroliberin (TRH) was found to be blunted compared to controls. Basal TSH levels were measured with two ultasensitive TSH assays. The immunoradiometric assays yielded fewer values outside the reference range in the NTI group than conventional thyroid function tests. This assay yielded undetectable basal TSH levels in all thyrotoxic patients and could reliably separate thyrotoxic patients from the NTI group. Basal TSH levels with ultrasensitive TSH assays correlated well with the TSH response to TRH (TSH) and could obviate the need for TRH tests. Ultrasensitive TSH assays are promising first line screening tests in NTI. 120 refs., 13 figs., 7 tabs

  4. Assessment of Genotoxicity of Ionizing radiation using Tradescantia-Comet assay

    Energy Technology Data Exchange (ETDEWEB)

    Han, Min; Ryu, Tae Ho; Hyun, Kyung Man; Kim, Jin Kyu [Korea Atomic Energy Research Institute, Jeongeup (Korea, Republic of); Wilhelmova, Nad [Institute of Experimental Botany, Prague (Czech Republic)

    2010-05-15

    Over the last two decades, several new methodologies for the detection of DNA damage have been developed. The comet assay is currently used in different areas of biological sciences to detect DNA damage. The comet assay, also called the single cell gel electrophoresis (SCGE) was first introduced by Ostling and Johanson as a microelectrophoretic technique for the direct visualization of DNA damage in individual cells. The comet assay, due to its simplicity, sensitivity and need of a few cells, is ideal as a short-term genotoxicity test. The comet assay can theoretically be applied to every type of eukaryotic cell, including plant cells. Plants are very useful as monitors of genetic effects caused by pollution in the atmosphere, water and soil. Although the genotoxic effects detected by Tradescantia tests cannot be associated with mutagenesis or even carcinogenesis in humans, these bioassays are very useful tools for screening the mutagenic potential in the environment. Experiments were conducted to study the genotoxic effects of ionizing radiations on the genome integrity, particularly of Tradescantia. The increasingly frequent use of Tradescantia as a sensitive environmental bioindicator of genotoxic effects. This study was designed to assess the genotoxicity of ionizing radiation using Tradescnatia-comet assay

  5. Assaying Used Nuclear Fuel Assemblies Using Lead Slowing-Down Spectroscopy and Singular Value Decomposition

    International Nuclear Information System (INIS)

    Kulisek, Jonathan A.; Anderson, Kevin K.; Casella, Andrew M.; Gesh, Christopher J.; Warren, Glen A.

    2013-01-01

    This study investigates the use of a Lead Slowing-Down Spectrometer (LSDS) for the direct and independent measurement of fissile isotopes in light-water nuclear reactor fuel assemblies. The current study applies MCNPX, a Monte Carlo radiation transport code, to simulate the measurement of the assay of the used nuclear fuel assemblies in the LSDS. An empirical model has been developed based on the calibration of the LSDS to responses generated from the simulated assay of six well-characterized fuel assemblies. The effects of self-shielding are taken into account by using empirical basis vectors calculated from the singular value decomposition (SVD) of a matrix containing the self-shielding functions from the assay of assemblies in the calibration set. The performance of the empirical algorithm was tested on version 1 of the Next-Generation Safeguards Initiative (NGSI) used fuel library consisting of 64 assemblies, as well as a set of 27 diversion assemblies, both of which were developed by Los Alamos National Laboratory. The potential for direct and independent assay of the sum of the masses of Pu-239 and Pu-241 to within 2%, on average, has been demonstrated

  6. A signal amplification assay for HSV type 1 viral DNA detection using nanoparticles and direct acoustic profiling

    Directory of Open Access Journals (Sweden)

    Hammond Richard

    2010-02-01

    Full Text Available Abstract Background Nucleic acid based recognition of viral sequences can be used together with label-free biosensors to provide rapid, accurate confirmation of viral infection. To enhance detection sensitivity, gold nanoparticles can be employed with mass-sensitive acoustic biosensors (such as a quartz crystal microbalance by either hybridising nanoparticle-oligonucleotide conjugates to complimentary surface-immobilised ssDNA probes on the sensor, or by using biotin-tagged target oligonucleotides bound to avidin-modified nanoparticles on the sensor. We have evaluated and refined these signal amplification assays for the detection from specific DNA sequences of Herpes Simplex Virus (HSV type 1 and defined detection limits with a 16.5 MHz fundamental frequency thickness shear mode acoustic biosensor. Results In the study the performance of semi-homogeneous and homogeneous assay formats (suited to rapid, single step tests were evaluated utilising different diameter gold nanoparticles at varying DNA concentrations. Mathematical models were built to understand the effects of mass transport in the flow cell, the binding kinetics of targets to nanoparticles in solution, the packing geometries of targets on the nanoparticle, the packing of nanoparticles on the sensor surface and the effect of surface shear stiffness on the response of the acoustic sensor. This lead to the selection of optimised 15 nm nanoparticles that could be used with a 6 minute total assay time to achieve a limit of detection sensitivity of 5.2 × 10-12 M. Larger diameter nanoparticles gave poorer limits of detection than smaller particles. The limit of detection was three orders of magnitude lower than that observed using a hybridisation assay without nanoparticle signal amplification. Conclusions An analytical model was developed to determine optimal nanoparticle diameter, concentration and probe density, which allowed efficient and rapid optimisation of assay parameters

  7. Comparison of Different Promoter Methylation Assays in Breast Cancer

    Directory of Open Access Journals (Sweden)

    Karijn P. M. Suijkerbuijk

    2010-01-01

    Full Text Available Background: Promoter hypermethylation has emerged as a promising cancer biomarker. Currently, a large variety of quantitative and non-quantitative techniques is used to measure methylation in clinical specimens. Here we directly compared three commonly used methylation assays and assessed the influence of tissue fixation, target sequence location and the amount of DNA on their performance.

  8. Self Shielding in Nuclear Fissile Assay Using LSDS

    International Nuclear Information System (INIS)

    Lee, Yong Deok; Park, Chang Je; Park, Geun Il; Song, Kee Chan

    2012-01-01

    The new technology for isotopic fissile material contents assay is under development at KAERI using lead slowing down spectrometer(LSDS). LSDS is very sensitive to distinguish fission signals from each fissile isotope in spent and recycled fuel. The accumulation of spent fuel is current big issue. The amount of spent fuels will reach the maximum storage capacity of the pools soon. Therefore, an interim storage must be searched and it should be optimized in design by applying accurate fissile content. When the storage has taken effect, all the nuclear materials must be also specified and verified for safety, economics and management. Generally, the spent fuel from PWR has unburned ∼1 % U235, produced ∼0.5 % plutonium from decay chain, ∼3 % fission products, ∼ 0.1 % minor actinides (MA) and uranium remainder. About 1.5 % fissile materials still exist in the spent fuel. Therefore, for reutilization of fissile materials in spent fuel at SFR, resource material is produced through pyro process. Fissile material contents in resource material must be analyzed before fabricating SFR fuel for reactor safety and economics. In assay of fissile content of spent fuel and recycled fuel, intense radiation background gives limitation on the direct analysis of fissile materials. However, LSDS is not influenced by such a radiation background in fissile assay. Based on the decided geometry setup, self shielding parameter was calculated at the fuel assay zone by introducing spent fuel or pyro produced nuclear material. When nuclear material is inserted into the assay area, the spent fuel assembly or pyro recycled fuel material perturbs the spatial distribution of the slowing down neutrons in lead and the prompt fast fission neutrons produced by fissile materials are also perturbed. The self shielding factor is interpreted as that how much of absorption is created inside the fuel area when it is in the lead. Self shielding effect provides a non-linear property in the isotopic

  9. Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.

    Science.gov (United States)

    Souberbielle, Jean-Claude; Fayol, Véronique; Sault, Corinne; Lawson-Body, Ethel; Kahan, André; Cormier, Catherine

    2005-02-01

    The recent development of nonradioactive automated assays for serum parathyroid hormone (PTH) and 25-hydroxyvitamin D (25OHD) has made measurement of these two hormones possible in many laboratories. In this study, we compared two new assays for PTH and 25OHD adapted on an automated analyzer, the LIAISON, with two manual immunoassays used worldwide. We studied 228 osteoporotic patients, 927 healthy individuals, 38 patients with primary hyperparathyroidism, and 167 hemodialyzed patients. Serum PTH was measured with the Allegro and the LIAISON assays, and 25OHD was measured with DiaSorin RIA and the LIAISON assay. Regression analysis was used to calculate decision thresholds for the LIAISON assays that were equivalent to those of the Allegro PTH and DiaSorin 25OHD assays. The 25OHD concentrations obtained with the LIAISON assay and the RIA in osteoporotic patients were well correlated (r = 0.83; P 50 nmol/L as eligible for the reference population for the LIAISON PTH assay. In this group, the 3rd-97th percentile interval for LIAISON PTH was 3-51 ng/L. Considering upper reference limits of 46 and 51 ng/L for the Allegro and LIAISON assays, respectively, the frequency of above-normal PTH concentrations in patients with primary hyperparathyroidism was similar in both assays. Regression analysis between serum PTH measured by the Allegro and LIAISON assays in 167 hemodialyzed patients and the corresponding Bland-Altman analysis of these data suggest that the LIAISON PTH assay tends to read higher than the Allegro assay at low concentrations but lower at high concentrations (>300 ng/L). Because clinical decision limits for both PTH and 25OHD should be assay specific, we propose equivalences between these assays and two manual assays used worldwide. These assay-specific decision limits should help potential users of the LIAISON PTH and 25OHD assays.

  10. [Determination of 25(OH)D serum levels in children with systemic lupus erythematosus and juvenile idiopathic arthritis].

    Science.gov (United States)

    Rosiles, Vanessa Hernández; Salazar, Carolina Duarte; Velazquez, Rocío Maldonado; Ruiz, Rodolfo Rivas; Clark, Patricia

    It is well recognized that vitamin D has a direct effect in bone and muscle and has been associated as well with some rheumatologic diseases. Reports in children are scarce. The aim of this study was to determine the concentration level of 25(OH)D in a group of patients with systemic lupus erythematosus (SLE) and juvenile idiopathic arthritis (JIA) and compare them with healthy controls. Vitamin D (25(OH)D) was measured with isotope-dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS), PTH with immunoradiometric assay (IRMA), calcium, phosphorus and alkaline phosphatase by colorimetric assay in 37 patients with SLE, 37 patients with JIA and 79 healthy controls. Mean 25(OH)D concentration levels were as follows: SLE 18.9±7.92ng/ml, JIA 21.97±5.55ng/ml and 23.6±3.07ng/ml in healthy controls. There was a significant difference between SLE patients vs. healthy controls (p <0.05); 29.7% of SLE patients, 35.1% of JIA patients and 31.6% of healthy controls had deficient levels of vitamin D. One third of the total sample of children in this study had deficient levels of vitamin D. Patients with SLE presented a significant difference compared with healthy controls. Copyright © 2015 Hospital Infantil de México Federico Gómez. Publicado por Masson Doyma México S.A. All rights reserved.

  11. Evaluation of Two Lyophilized Molecular Assays to Rapidly Detect Foot-and-Mouth Disease Virus Directly from Clinical Samples in Field Settings.

    Science.gov (United States)

    Howson, E L A; Armson, B; Madi, M; Kasanga, C J; Kandusi, S; Sallu, R; Chepkwony, E; Siddle, A; Martin, P; Wood, J; Mioulet, V; King, D P; Lembo, T; Cleaveland, S; Fowler, V L

    2017-06-01

    Accurate, timely diagnosis is essential for the control, monitoring and eradication of foot-and-mouth disease (FMD). Clinical samples from suspect cases are normally tested at reference laboratories. However, transport of samples to these centralized facilities can be a lengthy process that can impose delays on critical decision making. These concerns have motivated work to evaluate simple-to-use technologies, including molecular-based diagnostic platforms, that can be deployed closer to suspect cases of FMD. In this context, FMD virus (FMDV)-specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) and real-time RT-PCR (rRT-PCR) assays, compatible with simple sample preparation methods and in situ visualization, have been developed which share equivalent analytical sensitivity with laboratory-based rRT-PCR. However, the lack of robust 'ready-to-use kits' that utilize stabilized reagents limits the deployment of these tests into field settings. To address this gap, this study describes the performance of lyophilized rRT-PCR and RT-LAMP assays to detect FMDV. Both of these assays are compatible with the use of fluorescence to monitor amplification in real-time, and for the RT-LAMP assays end point detection could also be achieved using molecular lateral flow devices. Lyophilization of reagents did not adversely affect the performance of the assays. Importantly, when these assays were deployed into challenging laboratory and field settings within East Africa they proved to be reliable in their ability to detect FMDV in a range of clinical samples from acutely infected as well as convalescent cattle. These data support the use of highly sensitive molecular assays into field settings for simple and rapid detection of FMDV. © 2015 The Authors. Transboundary and Emerging Diseases Published by Blackwell Verlag GmbH.

  12. Comparison of a commercial ELISA and an immunoperoxidase monolayer assay to detect antibodies directed against porcine respiratory and reproductive syndrome virus

    NARCIS (Netherlands)

    Nodelijk, G.; Wensvoort, G.; Kroese, B.; Leengoed, van L.A.M.G.; Colijn, E.; Verheijden, J.H.M.

    1996-01-01

    A commercially available enzyme-linked immunosorbent assay (ELISA) for the detection of antibodies against porcine respiratory and reproductive syndrome virus (PRRSV) was compared to an immunoperoxidase monolayer assay (IPMA). Serum samples used were collected from pigs experimentally infected with

  13. Fissile Content Assay of Spent Fuel Using LSDS System

    International Nuclear Information System (INIS)

    Jeon, Ju Young; Lee, Yong Deok; Park, Chang Je

    2016-01-01

    About 1.5 % fissile materials still exist in the spent fuel. Therefore, for reutilization of fissile materials in spent fuel at SFR, resource material is produced through the pyro process. Fissile material contents in the resource material must be analyzed before fabricating SFR fuel for reactor safety and economics. The new technology for an isotopic fissile material content assay is under development at KAERI using a lead slowing down spectrometer (LSDS). LSDS is very sensitive to distinguish fission signals from each fissile isotope in spent and recycled fuel. In an assay of fissile content of spent fuel and recycled fuel, an intense radiation background gives limits the direct analysis of fissile materials. However, LSDS is not influenced by such a radiation background in a fissile assay. Based on the decided LSDS geometry set up, a self shielding parameter was calculated at the fuel assay zone by introducing spent fuel or pyro produced nuclear material. When nuclear material is inserted into the assay area, the spent fuel assembly or pyro recycled fuel material perturbs the spatial distribution of slowing down neutrons in lead and the prompt fast fission neutrons produced by fissile materials are also perturbed. The self shielding factor is interpreted as how much of the absorption is created inside the fuel area when it is in the lead. The self shielding effect provides a non-linear property in the isotopic fissile assay. When the self shielding is severe, the assay system becomes more complex and needs a special parameter to treat this non linear effect. Additionally, an assay of isotopic fissile content will contribute to an accuracy improvement of the burn-up code and increase the transparency and credibility for spent fuel storage and usage, as internationally increasing demand. The fissile contents result came out almost exactly with relative error ∼ 2% in case of Pu239, Pu241 for two different plutonium contents. In this study, meaningful results were

  14. Lead discovery for mammalian elongation of long chain fatty acids family 6 using a combination of high-throughput fluorescent-based assay and RapidFire mass spectrometry assay

    International Nuclear Information System (INIS)

    Takamiya, Mari; Sakurai, Masaaki; Teranishi, Fumie; Ikeda, Tomoko; Kamiyama, Tsutomu; Asai, Akira

    2016-01-01

    A high-throughput RapidFire mass spectrometry assay is described for elongation of very long-chain fatty acids family 6 (Elovl6). Elovl6 is a microsomal enzyme that regulates the elongation of C12-16 saturated and monounsaturated fatty acids. Elovl6 may be a new therapeutic target for fat metabolism disorders such as obesity, type 2 diabetes, and nonalcoholic steatohepatitis. To identify new Elovl6 inhibitors, we developed a high-throughput fluorescence screening assay in 1536-well format. However, a number of false positives caused by fluorescent interference have been identified. To pick up the real active compounds among the primary hits from the fluorescence assay, we developed a RapidFire mass spectrometry assay and a conventional radioisotope assay. These assays have the advantage of detecting the main products directly without using fluorescent-labeled substrates. As a result, 276 compounds (30%) of the primary hits (921 compounds) in a fluorescence ultra-high-throughput screening method were identified as common active compounds in these two assays. It is concluded that both methods are very effective to eliminate false positives. Compared with the radioisotope method using an expensive 14 C-labeled substrate, the RapidFire mass spectrometry method using unlabeled substrates is a high-accuracy, high-throughput method. In addition, some of the hit compounds selected from the screening inhibited cellular fatty acid elongation in HEK293 cells expressing Elovl6 transiently. This result suggests that these compounds may be promising lead candidates for therapeutic drugs. Ultra-high-throughput fluorescence screening followed by a RapidFire mass spectrometry assay was a suitable strategy for lead discovery against Elovl6. - Highlights: • A novel assay for elongation of very-long-chain fatty acids 6 (Elovl6) is proposed. • RapidFire mass spectrometry (RF-MS) assay is useful to select real screening hits. • RF-MS assay is proved to be beneficial because of

  15. Assessing protein oxidation by inorganic nanoparticles with enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Sun, Wenjie; Luna-Velasco, Antonia; Sierra-Alvarez, Reyes; Field, Jim A

    2013-03-01

    Growth in the nanotechnology industry is leading to increased production of engineered nanoparticles (NPs). This has given rise to concerns about the potential adverse and toxic effects to biological system and the environment. An important mechanism of NP toxicity is oxidative stress caused by the formation of reactive oxygen species (ROS) or via direct oxidation of biomolecules. In this study, a protein oxidation assay was developed as an indicator of biomolecule oxidation by NPs. The oxidation of the protein, bovine serum albumin (BSA) was evaluated with an enzyme-linked immunosorbent assay (ELISA) to measure the protein carbonyl derivatives formed from protein oxidation. The results showed that some NPs such as Cu(0), CuO, Mn(2)O(3), and Fe(0) caused oxidation of BSA; whereas, many of the other NPs tested were not reactive or very slowly reactive with BSA. The mechanisms involved in the oxidation of BSA protein by the reactive NPs could be attributed to the combined effects of ROS-dependent and direct protein oxidation mechanisms. The ELISA assay is a promising method for the assessment of protein oxidation by NPs, which can provide insights on NP toxicity mechanisms. Copyright © 2012 Wiley Periodicals, Inc.

  16. Biomonitoring of genotoxic risk in radar facility workers: comparison of the comet assay with micronucleus assay and chromatid breakage assay

    International Nuclear Information System (INIS)

    Garaj-Vrhovac, V.; Kopjar, N.

    2003-01-01

    Genotoxic risks of occupational exposure in a radar facility were evaluated by using alkaline comet assay, micronucleus assay and chromatid breakage assay on peripheral blood leukocytes in exposed subjects and corresponding controls. Results show that occupational exposure to microwave radiation correlates with an increase of genome damage in somatic cells. The levels of DNA damage in exposed subjects determined by using alkaline comet assay were increased compared to control and showed interindividual variations. Incidence of micronuclei was also significantly increased compared to baseline control values. After short exposure of cultured lymphocytes to bleomycin, cells of occupationally exposed subjects responded with high numbers of chromatid breaks. Although the level of chromosome damage generated by bleomycin varied greatly between individuals, in exposed subjects a significantly elevated number of chromatid breaks was observed. Our results support data reported in literature indicating that microwave radiation represents a potential DNA-damaging hazard. Alkaline comet assay is confirmed as a sensitive and highly reproducible technique for detection of primary DNA damage inflicted in somatic cells. Micronucleus assay was confirmed as reliable bio-markers of effect and chromatid breakage assay as sensitive bio-marker of individual cancer susceptibility. The results obtained also confirm the necessity to improve measures and to perform accurate health surveillance of individuals occupationally exposed to microwave radiation

  17. Direct detection of Leishmania from clinical samples.

    Science.gov (United States)

    Waitumbi, John N; Bast, Joshua; Nyakoe, Nancy; Magiri, Charles; Quintana, Miguel; Takhampunya, Ratree; Schuster, Anthony L; Van de Wyngaerde, Marshall T; McAvin, James C; Coleman, Russell E

    2017-01-01

    The ability to rapidly and accurately diagnose leishmaniasis is a military priority. Testing was conducted to evaluate diagnostic sensitivity and specificity of field-expedient Leishmania genus and visceral Leishmania specific dual-fluorogenic, hydrolysis probe (TaqMan), polymerase chain reaction assays previously established for use in vector surveillance. Blood samples of patients with confirmed visceral leishmaniasis and controls without the disease from Baringo District, Kenya, were tested. Leishmania genus assay sensitivity was 100% (14/14) and specificity was 84% (16/19). Visceral Leishmania assay sensitivity was 93% (13/14) and specificity 80% (4/5). Cutaneous leishmaniasis (CL) skin scrapes of patients from Honduras were also evaluated. Leishmania genus assay sensitivity was 100% (10/10). Visceral Leishmania assay specificity was 100% (10/10) from cutaneous leishmaniasis samples; no fluorescence above background was reported. These results show promise in a rapid, sensitive, and specific method for Leishmania direct detection from clinical samples.

  18. Analysis of primary cilia in directional cell migration in fibroblasts

    DEFF Research Database (Denmark)

    Christensen, Søren Tvorup; Veland, Iben; Schwab, Albrecht

    2013-01-01

    summarize selected methods in analyzing ciliary function in directional cell migration, including immunofluorescence microscopy, scratch assay, and chemotaxis assay by micropipette addition of PDGFRα ligands to cultures of fibroblasts. These methods should be useful not only in studying cell migration....... In particular, platelet-derived growth factor receptor alpha (PDGFRα) is compartmentalized to the primary cilium to activate signaling pathways that regulate reorganization of the cytoskeleton required for lamellipodium formation and directional migration in the presence of a specific ligand gradient. We...

  19. Comparative analysis and validation of the malachite green assay for the high throughput biochemical characterization of terpene synthases.

    Science.gov (United States)

    Vardakou, Maria; Salmon, Melissa; Faraldos, Juan A; O'Maille, Paul E

    2014-01-01

    Terpenes are the largest group of natural products with important and diverse biological roles, while of tremendous economic value as fragrances, flavours and pharmaceutical agents. Class-I terpene synthases (TPSs), the dominant type of TPS enzymes, catalyze the conversion of prenyl diphosphates to often structurally diverse bioactive terpene hydrocarbons, and inorganic pyrophosphate (PPi). To measure their kinetic properties, current bio-analytical methods typically rely on the direct detection of hydrocarbon products by radioactivity measurements or gas chromatography-mass spectrometry (GC-MS). In this study we employed an established, rapid colorimetric assay, the pyrophosphate/malachite green assay (MG), as an alternative means for the biochemical characterization of class I TPSs activity.•We describe the adaptation of the MG assay for turnover and catalytic efficiency measurements of TPSs.•We validate the method by direct comparison with established assays. The agreement of k cat/K M among methods makes this adaptation optimal for rapid evaluation of TPSs.•We demonstrate the application of the MG assay for the high-throughput screening of TPS gene libraries.

  20. Development of in vitro assay method with radioisotope

    International Nuclear Information System (INIS)

    Choi, Chang Woon; Lim, S. M.; An, S. H.; Woo, K. S.; Chung, W. S.; Lim, S. J.; Hong, S. W.; Oh, O. D.

    1999-04-01

    Radioimmunoassay (RIA) and related competitive protein-binding methods began a little over 20 years ago as a cumbersome research methodology in a few specialized laboratories. Endocrinology has been greatly enriched by the new knowledge that has come as a direct result of RIA methods. Establishment of the taxol RIA system will be expected to develop RIA for drug monitoring. Scintillation proximity assay was useful since any separation step is not required, it has the advantage of dealing with multiple samples. The increased sensitivity of the new assay in determining HCV RT([ 125 I]dUTP) suggests that it would be worth investigating whether the system can be applied to analysis. [ 125 I] lodotyramine with 98.5% radiochemical purity. Optimal background counts was certificated using varied radioactivity of radionuclides. Appropriate standard curve was obtained from SPA method successively, and the concentration of hCG from unknown serum was determined by standard curve. The result concentration of hCG from unknown serum was determined by synthesized successively and purified by HPLC system. Hybridoma reducing monoclonal anti thyroglobulin antibodies titer is measured by ELISA. These studies play an important role in development of in vitro assay with radionuclides

  1. Development of in vitro assay method with radioisotope

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Chang Woon; Lim, S. M.; An, S. H.; Woo, K. S.; Chung, W. S.; Lim, S. J.; Hong, S. W. [Korea Atomic Energy Research Institute. Korea Cancer Center Hospital, Seoul (Korea, Republic of); Oh, O. D. [Yonsei University, Seoul (Korea, Republic of)

    1999-04-01

    Radioimmunoassay (RIA) and related competitive protein-binding methods began a little over 20 years ago as a cumbersome research methodology in a few specialized laboratories. Endocrinology has been greatly enriched by the new knowledge that has come as a direct result of RIA methods. Establishment of the taxol RIA system will be expected to develop RIA for drug monitoring. Scintillation proximity assay was useful since any separation step is not required, it has the advantage of dealing with multiple samples. The increased sensitivity of the new assay in determining HCV RT([{sup 125}I]dUTP) suggests that it would be worth investigating whether the system can be applied to analysis. [{sup 125}I] lodotyramine with 98.5% radiochemical purity. Optimal background counts was certificated using varied radioactivity of radionuclides. Appropriate standard curve was obtained from SPA method successively, and the concentration of hCG from unknown serum was determined by standard curve. The result concentration of hCG from unknown serum was determined by synthesized successively and purified by HPLC system. Hybridoma reducing monoclonal anti thyroglobulin antibodies titer is measured by ELISA. These studies play an important role in development of in vitro assay with radionuclides.

  2. Development of a loop-mediated Isothermal amplification assay for sensitive and rapid detection of Vibrio parahaemolyticus

    Directory of Open Access Journals (Sweden)

    Kawahara Ryuji

    2008-09-01

    Full Text Available Abstract Background Vibrio parahaemolyticus is a marine seafood-borne pathogen causing gastrointestinal disorders in humans. Thermostable direct hemolysin (TDH and TDH-related hemolysin (TRH are known as major virulence determinants of V. parahaemolyticus. Most V. parahaemolyticus isolates from the environment do not produce TDH or TRH. Total V. parahaemolyticus has been used as an indicator for control of seafood contamination toward prevention of infection. Detection of total V. parahaemolyticus using conventional culture- and biochemical-based assays is time-consuming and laborious, requiring more than three days. Thus, we developed a novel and highly specific loop-mediated isothermal amplification (LAMP assay for the sensitive and rapid detection of Vibrio parahaemolyticus. Results The assay provided markedly more sensitive and rapid detection of V. parahaemolyticus strains than conventional biochemical and PCR assays. The assay correctly identified 143 V. parahaemolyticus strains, but did not detect 33 non-parahaemolyticus Vibrio and 56 non-Vibrio strains. Sensitivity of the LAMP assay for direct detection of V. parahaemolyticus in pure cultures and in spiked shrimp samples was 5.3 × 102 CFU per ml/g (2.0 CFU per reaction. The sensitivity of the LAMP assay was 10-fold more sensitive than that of the conventional PCR assay. The LAMP assay was markedly faster, requiring for amplification 13–22 min in a single colony on TCBS agar from each of 143 V. parahaemolyticus strains and less than 35 min in spiked shrimp samples. The LAMP assay for detection of V. parahaemolyticus required less than 40 min in a single colony on thiosulfate citrate bile salt sucrose (TCBS agar and 60 min in spiked shrimp samples from the beginning of DNA extraction to final determination. Conclusion The LAMP assay is a sensitive, rapid and simple tool for the detection of V. parahaemolyticus and will facilitate the surveillance for control of contamination of V

  3. Use of global assays to understand clinical phenotype in congenital factor VII deficiency.

    Science.gov (United States)

    Greene, L A; Goldenberg, N A; Simpson, M L; Villalobos-Menuey, E; Bombardier, C; Acharya, S S; Santiago-Borrero, P J; Cambara, A; DiMichele, D M

    2013-09-01

    Congenital factor VII (FVII) deficiency is characterized by genotypic variability and phenotypic heterogeneity. Traditional screening and factor assays are unable to reliably predict clinical bleeding phenotype and guide haemorrhage prevention strategy. Global assays of coagulation and fibrinolysis may better characterize overall haemostatic balance and aid in haemorrhagic risk assessment. We evaluated the ability of novel global assays to better understand clinical bleeding severity in congenital FVII deficiency. Subjects underwent central determination of factor VII activity (FVII:C) as well as clot formation and lysis (CloFAL) and simultaneous thrombin and plasmin generation (STP) global assay analysis. A bleeding score was assigned to each subject through medical chart review. Global assay parameters were analysed with respect to bleeding score and FVII:C. Subgroup analyses were performed on paediatric subjects and subjects with FVII ≥ 1 IU dL(-1). CloFAL fibrinolytic index (FI2 ) inversely correlated with FVII:C while CloFAL maximum amplitude (MA) and STP maximum velocity of thrombin generation (VT max) varied directly with FVII:C. CloFAL FI2 directly correlated with bleeding score among subjects in both the total cohort and paediatric subcohort, but not among subjects with FVII ≥ 1 IU dL(-1) . Among subjects with FVII ≥ 1 IU dL(-1), STP time to maximum velocity of thrombin generation and time to maximum velocity of plasmin generation inversely correlated with bleeding score. These preliminary findings suggest a novel potential link between a hyperfibrinolytic state in bleeding severity and congenital FVII deficiency, an observation that should be further explored. © 2013 John Wiley & Sons Ltd.

  4. OpenComet: An automated tool for comet assay image analysis

    Directory of Open Access Journals (Sweden)

    Benjamin M. Gyori

    2014-01-01

    Full Text Available Reactive species such as free radicals are constantly generated in vivo and DNA is the most important target of oxidative stress. Oxidative DNA damage is used as a predictive biomarker to monitor the risk of development of many diseases. The comet assay is widely used for measuring oxidative DNA damage at a single cell level. The analysis of comet assay output images, however, poses considerable challenges. Commercial software is costly and restrictive, while free software generally requires laborious manual tagging of cells. This paper presents OpenComet, an open-source software tool providing automated analysis of comet assay images. It uses a novel and robust method for finding comets based on geometric shape attributes and segmenting the comet heads through image intensity profile analysis. Due to automation, OpenComet is more accurate, less prone to human bias, and faster than manual analysis. A live analysis functionality also allows users to analyze images captured directly from a microscope. We have validated OpenComet on both alkaline and neutral comet assay images as well as sample images from existing software packages. Our results show that OpenComet achieves high accuracy with significantly reduced analysis time.

  5. Real‑time, fast neutron detection for stimulated safeguards assay

    International Nuclear Information System (INIS)

    Joyce, Malcolm J.; Adamczyk, Justyna; Plenteda, Romano; Aspinall, Michael D.; Cave, Francis D.

    2015-01-01

    The advent of low‑hazard organic liquid scintillation detectors and real‑time pulse‑shape discrimination (PSD) processing has suggested a variety of modalities by which fast neutrons, as opposed to neutrons moderated prior to detection, can be used directly to benefit safeguards needs. In this paper we describe a development of a fast‑neutron based safeguards assay system designed for the assessment of 235 U content in fresh fuel. The system benefits from real‑time pulse‑shape discrimination processing and auto‑calibration of the detector system parameters to ensure a rapid and effective set‑up protocol. These requirements are essential in optimising the speed and limit of detection of the fast neutron technique, whilst minimising the intervention needed to perform the assay.

  6. A rapid and efficient branched DNA hybridization assay to titer lentiviral vectors.

    Science.gov (United States)

    Nair, Ayyappan; Xie, Jinger; Joshi, Sarasijam; Harden, Paul; Davies, Joan; Hermiston, Terry

    2008-11-01

    A robust assay to titer lentiviral vectors is imperative to qualifying their use in drug discovery, target validation and clinical applications. In this study, a novel branched DNA based hybridization assay was developed to titer lentiviral vectors by quantifying viral RNA genome copy numbers from viral lysates without having to purify viral RNA, and this approach was compared with other non-functional (p24 protein ELISA and viral RT-qPCR) and a functional method (reporter gene expression) used commonly. The RT-qPCR method requires purification of viral RNA and the accuracy of titration therefore depends on the efficiency of purification; this requirement is ameliorated in the hybridization assay as RNA is measured directly in viral lysates. The present study indicates that the hybridization based titration assay performed on viral lysates was more accurate and has additional advantages of being rapid, robust and not dependent on transduction efficiency in different cell types.

  7. Development of a Rapid Insulin Assay by Homogenous Time-Resolved Fluorescence.

    Directory of Open Access Journals (Sweden)

    Zachary J Farino

    Full Text Available Direct measurement of insulin is critical for basic and clinical studies of insulin secretion. However, current methods are expensive and time-consuming. We developed an insulin assay based on homogenous time-resolved fluorescence that is significantly more rapid and cost-effective than current commonly used approaches. This assay was applied effectively to an insulin secreting cell line, INS-1E cells, as well as pancreatic islets, allowing us to validate the assay by elucidating mechanisms by which dopamine regulates insulin release. We found that dopamine functioned as a significant negative modulator of glucose-stimulated insulin secretion. Further, we showed that bromocriptine, a known dopamine D2/D3 receptor agonist and newly approved drug used for treatment of type II diabetes mellitus, also decreased glucose-stimulated insulin secretion in islets to levels comparable to those caused by dopamine treatment.

  8. Rapid activity-directed screening of estrogens by parallel coupling of liquid chromatography with a functional gene reporter assay and mass spectrometry

    NARCIS (Netherlands)

    Jonker, W.; Lamoree, M.H.; Houtman, C.J.; Hamers, T.; Somsen, G.W.; Kool, J.

    2015-01-01

    In this study we developed a new LC nanofractionation platform that combines a human cell (BG1.Luc) gene reporter assay with a high resolution mass spectrometer for the detection and identification of estrogenic and anti-estrogenic compounds in environmental waters. The selection of this assay was

  9. Assay strategies and methods for phospholipases

    International Nuclear Information System (INIS)

    Reynolds, L.J.; Washburn, W.N.; Deems, R.A.; Dennis, E.A.

    1991-01-01

    Of the general considerations discussed, the two issues which are most important in choosing an assay are (1) what sensitivity is required to assay a particular enzyme and (2) whether the assay must be continuous. One can narrow the options further by considering substrate availability, enzyme specificity, assay convenience, or the presence of incompatible side reactions. In addition, the specific preference of a particular phospholipase for polar head group, micellar versus vesicular substrates, and anionic versus nonionic detergents may further restrict the options. Of the many assays described in this chapter, several have limited applicability or serious drawbacks and are not commonly employed. The most commonly used phospholipase assays are the radioactive TLC assay and the pH-stat assay. The TLC assay is probably the most accurate, sensitive assay available. These aspects often outweigh the disadvantages of being discontinuous, tedious, and expensive. The radioactive E. coli assay has become popular recently as an alternative to the TLC assay for the purification of the mammalian nonpancreatic phospholipases. The assay is less time consuming and less expensive than the TLC assay, but it is not appropriate when careful kinetics are required. Where less sensitivity is needed, or when a continuous assay is necessary, the pH-stat assay is often employed. With purified enzymes, when free thiol groups are not present, a spectrophotometric thiol assay can be used. This assay is ∼ as sensitive as the pH-stat assay but is more convenient and more reproducible, although the substrate is not available commercially. Despite the many assay choices available, the search continues for a convenient, generally applicable assay that is both sensitive and continuous

  10. Flow Cytometry-Based Bead-Binding Assay for Measuring Receptor Ligand Specificity

    NARCIS (Netherlands)

    Sprokholt, Joris K.; Hertoghs, Nina; Geijtenbeek, Teunis B. H.

    2016-01-01

    In this chapter we describe a fluorescent bead-binding assay, which is an efficient and feasible method to measure interaction between ligands and receptors on cells. In principle, any ligand can be coated on fluorescent beads either directly or via antibodies. Binding between ligand-coated beads

  11. Diagnostic value of islet autoantibody assays practised in Russia. 1. Classic immunofluorescence islet cell antibody assay, immunoradiometric glutamic acid decarboxylase antibody assay, and ELISA tyrosine phosphatase antibody and insulin antibody assays

    Directory of Open Access Journals (Sweden)

    Alexei V. Timofeev

    2016-09-01

    Conclusions. We recommend to use ICA, IA-2A and GADA tests surveyed in our study for diagnosis of DM type 1 and differential diagnosis of DM. We don’t recommend IA testing with an Orgentec Anti-Insulin ELISA kit for usage in clinical practice.

  12. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    Science.gov (United States)

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Bayer HealthCare LLC, Diagnostics Division, has developed several new assays on the ADVIA Centaur immunoassay system for the detection of markers of hepatitis B virus infection in human serum and plasma. This panel includes assays for: hepatitis B surface antigen (HBsAg), a confirmatory test method for HBsAg, antibodies to hepatitis B surface antigen (anti-HBs), IgM and IgG antibodies to hepatitis B core antigen (anti-HBc Total) and IgM antibodies to hepatitis B core antigen (anti-HBc IgM). These assays employ magnetic particle separation technology with direct chemiluminescence for optimal assay performance. All of the assays are fully automated, require sample volumes ranging from 15 microl to 100 microl (with the exception of the ADVIA Centaur HBsAg Confirmatory Assay, which requires 2 x 100 microl), and have throughputs of up to 240 tests per hour. The five ADVIA Centaur HBV assays were tested in extensive performance evaluations conducted at two sites in Europe. The performance evaluations, which included samples from HBV-infected individuals, blood donors, hospitalized/clinical patients, and HBV vaccinees (for Anti-HBs evaluation), generated performance data in support of obtaining the Communautés Européennes (CE) mark for European market distribution. The HBV performance evaluations resulted in an overall diagnostic specificity > 99%, i.e. 99.94% for the ADVIA Centaur HBsAg Assay, 100% for the ADVIA Centaur Anti-HBs Assay, 100% for the ADVIA Centaur HBc IgM Assay and 99.94% for the ADVIA Centaur HBc Total Assay. All of the ADVIA Centaur assays showed a very good diagnostic sensitivity on these populations with 100% for the ADVIA Centaur HBsAg Assay, 99.0% for the ADVIA Centaur Anti-HBs Assay, 98.53% for the ADVIA Centaur HBc IgM Assay and 100% for the ADVIA Centaur HBc Total Assay. The ADVIA Centaur HBsAg Confirmatory Test confirmed 100% of the positive HBsAg samples. Testing of interfering substances and potential cross-reacting samples for all ADVIA

  13. PCR-based assays versus direct sequencing for evaluating the effect of KRAS status on anti-EGFR treatment response in colorectal cancer patients: a systematic review and meta-analysis.

    Directory of Open Access Journals (Sweden)

    Lianfeng Shan

    Full Text Available The survival rate of colorectal cancer (CRC patients carrying wild-type KRAS is significantly increased by combining anti-EGFR monoclonal antibody (mAb with standard chemotherapy. However, conflicting data exist in both the wild-type KRAS and mutant KRAS groups, which strongly challenge CRC anti-EGFR treatment. Here we conducted a meta-analysis in an effort to provide more reliable information regarding anti-EGFR treatment in CRC patients.We searched full reports of randomized clinical trials using Medline, the American Society of Clinical Oncology (ASCO, and the European Society for Medical Oncology (ESMO. Two investigators independently screened the published literature according to our inclusive and exclusive criteria and the relative data were extracted. We used Review Manager 5.2 software to analyze the data.The addition of anti-EGFR mAb to standard chemotherapy significantly improved both progression-free survival (PFS and median overall survival (mOS in the wild-type KRAS group; hazard ratios (HRs for PFS and mOS were 0.70 [95% confidence interval (CI, 0.58-0.84] and 0.83 [95% CI, 0.75-0.91], respectively. In sub-analyses of the wild-type KRAS group, when PCR-based assays are employed, PFS and mOS notably increase: the HRs were 0.74 [95% CI, 0.62-0.88] and 0.87 [95% CI, 0.78-0.96], respectively. In sub-analyses of the mutant KRAS group, neither PCR-based assays nor direct sequencing enhance PFS or mOS.Our data suggest that PCR-based assays with high sensitivity and specificity allow accurate identification of patients with wild-type KRAS and thus increase PFS and mOS. Furthermore, such assays liberate patients with mutant KRAS from unnecessary drug side effects, and provide them an opportunity to receive appropriate treatment. Thus, establishing a precise standard reference test will substantially optimize CRC-targeted therapies.

  14. Solid phase assays

    International Nuclear Information System (INIS)

    Reese, M.G.; Johnson, L.R.; Ransom, D.K.

    1980-01-01

    In a solid phase assay for quantitative determination of biological and other analytes, a sample such as serum is contacted with a receptor for the analyte being assayed, the receptor being supported on a solid support. No tracer for the analyte is added to the sample before contacting with the receptor; instead the tracer is contacted with the receptor after unbound analyte has been removed from the receptor. The assay can be otherwise performed in a conventional manner but can give greater sensitivity. (author)

  15. Detection of induced male germline mutation: Correlations and comparisons between traditional germline mutation assays, transgenic rodent assays and expanded simple tandem repeat instability assays

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Timothy M. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ont., K1S 5B6 (Canada); Lambert, Iain B. [Department of Biology, Carleton University, 1125 Colonel By Drive, Ottawa, Ont., K1S 5B6 (Canada); Williams, Andrew [Biostatistics and Epidemiology Division, Safe Environments Programme, 6604B, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Douglas, George R. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada); Yauk, Carole L. [Mutagenesis Section, Environmental and Occupational Toxicology Division, Safe Environments Programme, 0803A, Health Canada, Ottawa, Ont., K1A 0K9 (Canada)]. E-mail: carole_yauk@hc-sc.gc.ca

    2006-06-25

    Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently-the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development.

  16. Detection of induced male germline mutation: Correlations and comparisons between traditional germline mutation assays, transgenic rodent assays and expanded simple tandem repeat instability assays

    International Nuclear Information System (INIS)

    Singer, Timothy M.; Lambert, Iain B.; Williams, Andrew; Douglas, George R.; Yauk, Carole L.

    2006-01-01

    Several rodent assays are capable of monitoring germline mutation. These include traditional assays, such as the dominant lethal (DL) assay, the morphological specific locus (SL) test and the heritable translocation (HT) assay, and two assays that have been developed more recently-the expanded simple tandem repeat (ESTR) and transgenic rodent (TGR) mutation assays. In this paper, we have compiled the limited amount of experimental data that are currently available to make conclusions regarding the comparative ability of the more recently developed assays to detect germline mutations induced by chemical and radiological agents. The data suggest that ESTR and TGR assays are generally comparable with SL in detecting germline mutagenicity induced by alkylating agents and radiation, though TGR offered less sensitivity than ESTR in some cases. The DL and HT assays detect clastogenic events and are most susceptible to mutations arising in post-spermatogonial cells, and they may not provide the best comparisons with TGR and ESTR instability. The measurement of induced ESTR instability represents a relatively sensitive method of identifying agents causing germline mutation in rodents, and may also be useful for bio-monitoring exposed individuals in the human population. Any future use of the TGR and ESTR germline mutation assays in a regulatory testing context will entail more robust and extensive characterization of assay performance. This will require substantially more data, including experiments measuring multiple endpoints, a greatly expanded database of chemical agents and a focus on characterizing stage-specific activity of mutagens in these assays, preferably by sampling epididymal sperm exposed at defined pre-meiotic, meiotic and post-meiotic stages of development

  17. Analytical and clinical evaluation of the Abbott RealTime hepatitis B sequencing assay.

    Science.gov (United States)

    Huh, Hee Jae; Kim, Ji-Youn; Lee, Myoung-Keun; Lee, Nam Yong; Kim, Jong-Won; Ki, Chang-Seok

    2016-12-01

    Long-term nucleoside analogue (NA) treatment leads to selection for drug-resistant mutations in patients undergoing hepatitis B virus (HBV) therapy. The Abbott RealTime HBV Sequencing assay (Abbott assay; Abbott Molecular Inc., Des Plaines, IL, USA) targets the reverse transcriptase region of the polymerase gene and as such has the ability to detect NA resistance-associated mutations in HBV. We evaluated the analytical performance of the Abbott assay and compared its diagnostic performance to that of a laboratory-developed nested-PCR and sequencing method. The analytical sensitivity of the Abbott assay was determined using a serially-diluted WHO International Standard. To validate the clinical performances of the Abbott assay and the laboratory-developed assay, 89 clinical plasma samples with various levels of HBV DNA were tested using both assays. The limit of detection of the Abbott assay, was 210IU/ml and it successfully detected mutations when the mutant types were present at levels ≥20%. Among 89 clinical specimens, 43 and 42 were amplification positive in the Abbott and laboratory-developed assays, respectively, with 87.6% overall agreement (78/89; 95% confidence interval [CI], 78.6-93.4). The Abbott assay failed to detect the minor mutant populations in two specimens, and therefore overall concordance was 85.3% (76/89), and the kappa value was 0.79 (95% CI, 0.67-0.90). The Abbott assay showed comparable diagnostic performance to laboratory-developed nested PCR followed by direct sequencing, and may be useful as a routine method for detecting HBV NA resistance-associated mutations in clinical laboratory settings. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Targeting Anti-Cancer Active Compounds: Affinity-Based Chromatographic Assays

    OpenAIRE

    de Moraes, Marcela Cristina; Cardoso, Carmen Lucia; Seidl, Claudia; Moaddel, Ruin; Cass, Quezia Bezerra

    2016-01-01

    Affinity-based chromatography assays encompass the use of solid supports containing immobilized biological targets to monitor binding events in the isolation , identification and/or characterization of bioactive compounds. This powerful bioanalytical technique allows the screening of potential binders through fast analyses that can be directly performed using isolated substances or complex matrices. An overview of the recent researches in frontal and zonal affinity-based chromatography screen...

  19. Miniaturized Aptamer-Based Assays for Protein Detection

    Directory of Open Access Journals (Sweden)

    Alessandro Bosco

    2016-09-01

    Full Text Available The availability of devices for cancer biomarker detection at early stages of the disease is one of the most critical issues in biomedicine. Towards this goal, to increase the assay sensitivity, device miniaturization strategies empowered by the employment of high affinity protein binders constitute a valuable approach. In this work we propose two different surface-based miniaturized platforms for biomarker detection in body fluids: the first platform is an atomic force microscopy (AFM-based nanoarray, where AFM is used to generate functional nanoscale areas and to detect biorecognition through careful topographic measurements; the second platform consists of a miniaturized electrochemical cell to detect biomarkers through electrochemical impedance spectroscopy (EIS analysis. Both devices rely on robust and highly-specific protein binders as aptamers, and were tested for thrombin detection. An active layer of DNA-aptamer conjugates was immobilized via DNA directed immobilization on complementary single-stranded DNA self-assembled monolayers confined on a nano/micro area of a gold surface. Results obtained with these devices were compared with the output of surface plasmon resonance (SPR assays used as reference. We succeeded in capturing antigens in concentrations as low as a few nM. We put forward ideas to push the sensitivity further to the pM range, assuring low biosample volume (μL range assay conditions.

  20. A facile molecularly imprinted polymer-based fluorometric assay for detection of histamine

    DEFF Research Database (Denmark)

    Feng, Xiaotong; Ashley, Jon; Zhou, Tongchang

    2018-01-01

    urgently needed. In this paper, we developed a facile and cost-effective molecularly imprinted polymer (MIP)-based fluorometric assay to directly quantify histamine. Histamine-specific MIP nanoparticles (nanoMIPs) were synthesized using a modified solid-phase synthesis method. They were then immobilized...

  1. Evaluation of total PSA assay on vitros ECi and correlation with Kryptor-PSA assay.

    Science.gov (United States)

    Cassinat, B; Wacquet, M; Toubert, M E; Rain, J D; Schlageter, M H

    2001-01-01

    An increasing number of multiparametric immuno-analysers for PSA assays are available. As different immuno-assays may vary in their analytical quality and their accuracy for the follow-up of patients, expertise is necessary for each new assay. The PSA assay on the Vitros-ECi analyser has been evaluated and compared with the PSA assay from the Kryptor analyser. Variation coefficients were 0.91 to 1.98% for within-run assays, and 4.2% to 5.4% for interassay (PSA levels = 0.8 microgram/L to 33.6 micrograms/L). Dilution tests showed 93 to 136% recovery until 70 micrograms/L PSA. Functional sensitivity was estimated at 0.03 microgram/L. Equimolarity of the test was confirmed. Correlation of PSA levels measured with Vitros-ECi and Kryptor analysers displayed a correlation coefficient r2 of 0.9716. The half-lives and doubling times of PSA were similar using both methods. Vitros-ECi PSA assay meets the major criteria for the management of prostate cancer patients.

  2. Hormone assay

    International Nuclear Information System (INIS)

    Eisentraut, A.M.

    1977-01-01

    An improved radioimmunoassay is described for measuring total triiodothyronine or total thyroxine levels in a sample of serum containing free endogenous thyroid hormone and endogenous thyroid hormone bound to thyroid hormone binding protein. The thyroid hormone is released from the protein by adding hydrochloric acid to the serum. The pH of the separated thyroid hormone and thyroid hormone binding protein is raised in the absence of a blocking agent without interference from the endogenous protein. 125 I-labelled thyroid hormone and thyroid hormone antibodies are added to the mixture, allowing the labelled and unlabelled thyroid hormone and the thyroid hormone antibody to bind competitively. This results in free thyroid hormone being separated from antibody bound thyroid hormone and thus the unknown quantity of thyroid hormone may be determined. A thyroid hormone test assay kit is described for this radioimmunoassay. It provides a 'single tube' assay which does not require blocking agents for endogenous protein interference nor an external solid phase sorption step for the separation of bound and free hormone after the competitive binding step; it also requires a minimum number of manipulative steps. Examples of the assay are given to illustrate the reproducibility, linearity and specificity of the assay. (UK)

  3. Development and performance assessment of a luminex xMAP® direct hybridization assay for the detection and identification of indoor air fungal contamination.

    Science.gov (United States)

    Libert, Xavier; Packeu, Ann; Bureau, Fabrice; Roosens, Nancy H; De Keersmaecker, Sigrid C J

    2017-01-01

    Considered as a public health problem, indoor fungal contamination is generally monitored using classical protocols based on culturing. However, this culture dependency could influence the representativeness of the fungal population detected in an analyzed sample as this includes the dead and uncultivable fraction. Moreover, culture-based protocols are often time-consuming. In this context, molecular tools are a powerful alternative, especially those allowing multiplexing. In this study a Luminex xMAP® assay was developed for the simultaneous detection of 10 fungal species which are most frequently in indoor air and that may cause health problems. This xMAP® assay was found to be sensitive, i.e. its limit of detection is ranging between 0.05 and 0.01 ng of gDNA. The assay was subsequently tested with environmental air samples which were also analyzed with a classical protocol. All the species identified with the classical method were also detected with the xMAP® assay, however in a shorter time frame. These results demonstrate that the Luminex xMAP® fungal assay developed in this study could contribute to the improvement of public health and specifically to the indoor fungal contamination treatment.

  4. Development and performance assessment of a luminex xMAP® direct hybridization assay for the detection and identification of indoor air fungal contamination.

    Directory of Open Access Journals (Sweden)

    Xavier Libert

    Full Text Available Considered as a public health problem, indoor fungal contamination is generally monitored using classical protocols based on culturing. However, this culture dependency could influence the representativeness of the fungal population detected in an analyzed sample as this includes the dead and uncultivable fraction. Moreover, culture-based protocols are often time-consuming. In this context, molecular tools are a powerful alternative, especially those allowing multiplexing. In this study a Luminex xMAP® assay was developed for the simultaneous detection of 10 fungal species which are most frequently in indoor air and that may cause health problems. This xMAP® assay was found to be sensitive, i.e. its limit of detection is ranging between 0.05 and 0.01 ng of gDNA. The assay was subsequently tested with environmental air samples which were also analyzed with a classical protocol. All the species identified with the classical method were also detected with the xMAP® assay, however in a shorter time frame. These results demonstrate that the Luminex xMAP® fungal assay developed in this study could contribute to the improvement of public health and specifically to the indoor fungal contamination treatment.

  5. Assay for intrinsic factor based on blocking of the R binder of gastric juice by cobinamide

    International Nuclear Information System (INIS)

    Begley, J.A.; Trachtenberg, A.

    1979-01-01

    An in vitro assay for measurement of gastric juice intrinsic factor (IF) was developed based on the ability of the cobinamide (Cbi) [(CN, OH) Cbi] to bind to the gastric juice R-type binders of cobalamin (Cbl) and not to the IF binder. Subsequently added radioactive Cbl, CN-[ 57 Co] Cbl, binds only to the IF binders and allows for direct measurement of this Cbl binding protein. This Cbi blocking assay was found to function as well as the more conventional methods of IF measurement, G-100 column chromatography, and IF blocking antibody assay. The present assay has the advantage of eliminating the need for elaborate forms of protein separation and does not rely on a source of antibody

  6. Label-Free, LC-MS-Based Assays to Quantitate Small-Molecule Antagonist Binding to the Mammalian BLT1 Receptor.

    Science.gov (United States)

    Chen, Xun; Stout, Steven; Mueller, Uwe; Boykow, George; Visconti, Richard; Siliphaivanh, Phieng; Spencer, Kerrie; Presland, Jeremy; Kavana, Michael; Basso, Andrea D; McLaren, David G; Myers, Robert W

    2017-08-01

    We have developed and validated label-free, liquid chromatography-mass spectrometry (LC-MS)-based equilibrium direct and competition binding assays to quantitate small-molecule antagonist binding to recombinant human and mouse BLT1 receptors expressed in HEK 293 cell membranes. Procedurally, these binding assays involve (1) equilibration of the BLT1 receptor and probe ligand, with or without a competitor; (2) vacuum filtration through cationic glass fiber filters to separate receptor-bound from free probe ligand; and (3) LC-MS analysis in selected reaction monitoring mode for bound probe ligand quantitation. Two novel, optimized probe ligands, compounds 1 and 2, were identified by screening 20 unlabeled BLT1 antagonists for direct binding. Saturation direct binding studies confirmed the high affinity, and dissociation studies established the rapid binding kinetics of probe ligands 1 and 2. Competition binding assays were established using both probe ligands, and the affinities of structurally diverse BLT1 antagonists were measured. Both binding assay formats can be executed with high specificity and sensitivity and moderate throughput (96-well plate format) using these approaches. This highly versatile, label-free method for studying ligand binding to membrane-associated receptors should find broad application as an alternative to traditional methods using labeled ligands.

  7. Versatile High-Throughput Fluorescence Assay for Monitoring Cas9 Activity.

    Science.gov (United States)

    Seamon, Kyle J; Light, Yooli K; Saada, Edwin A; Schoeniger, Joseph S; Harmon, Brooke

    2018-06-05

    The RNA-guided DNA nuclease Cas9 is now widely used for the targeted modification of genomes of human cells and various organisms. Despite the extensive use of Clustered Regularly Interspaced Palindromic Repeats (CRISPR) systems for genome engineering and the rapid discovery and engineering of new CRISPR-associated nucleases, there are no high-throughput assays for measuring enzymatic activity. The current laboratory and future therapeutic uses of CRISPR technology have a significant risk of accidental exposure or clinical off-target effects, underscoring the need for therapeutically effective inhibitors of Cas9. Here, we develop a fluorescence assay for monitoring Cas9 nuclease activity and demonstrate its utility with S. pyogenes (Spy), S. aureus (Sau), and C. jejuni (Cje) Cas9. The assay was validated by quantitatively profiling the species specificity of published anti-CRISPR (Acr) proteins, confirming the reported inhibition of Spy Cas9 by AcrIIA4 and Cje Cas9 by AcrIIC1 and no inhibition of Sau Cas9 by either anti-CRISPR. To identify drug-like inhibitors, we performed a screen of 189 606 small molecules for inhibition of Spy Cas9. Of 437 hits (0.2% hit rate), six were confirmed as Cas9 inhibitors in a direct gel electrophoresis secondary assay. The high-throughput nature of this assay makes it broadly applicable for the discovery of additional Cas9 inhibitors or the characterization of Cas9 enzyme variants.

  8. High-throughput immunoturbidimetric assays for in-process determination of polyclonal antibody concentration and functionality in crude samples

    DEFF Research Database (Denmark)

    Bak, Hanne; Kyhse-Andersen, J.; Thomas, O.R.T.

    2007-01-01

    We present fast, simple immunoturbidimetric assays suitable for direct determination of antibody 'concentration' and 'functionality' in crude samples, such as in-process samples taken at various stages during antibody purification. Both assays display excellent linearity and analytical recovery. ...... antibodies, require only basic laboratory equipment, are robust, fast, cheap, easy to perform, and readily adapted to automation....

  9. Evaluation of the radioimmunoassay, indirect enzyme linked immunosorbent assay, and dot blot assay for the identification of Xanthomonas campestris pv. phaseoli

    Energy Technology Data Exchange (ETDEWEB)

    Malin, E; Belden, E L; Roth, D

    1985-09-01

    A radioimmunoassay (RIA), an indirect competitive enzyme-linked immunosorbent assay (ELISA), and a dot-blot modification of the ELISA were evaluated for detection and identification of Xanthomonas campestris pv. phaseoli (X. c. pv. phaseoli). RIA and the dot blot tests were specific for X. c. pv. phaseoli; however, significant cross reactions occurred in the indirect competitive ELISA when using anti-X. c. pv. phaseoli antiserum against other closely related bacteria. The sensitivity level of all procedures for X. c. pv. phaseoli was approximately l0/sup 5/ colony forming unitsmL. All procedures were unsatisfactory in reliably detecting low levels of X. c. pv. phaseoli directly from extracts of bean seed. However when used in conjunction with ilution plating the dot blot assay and the RIA would be useful in specifically identifying X. c. pv. phaseoli. The relative merits of these tests for identification of X. c. pv. phaseoli are discussed.

  10. The development and application of the two real-time RT-PCR assays to detect the pathogen of HFMD.

    Directory of Open Access Journals (Sweden)

    Aili Cui

    Full Text Available Large-scale Hand, Foot, and Mouth Disease (HFMD outbreaks have frequently occurred in China since 2008, affecting more than one million children and causing several hundred children deaths every year. The pathogens of HFMD are mainly human enteroviruses (HEVs. Among them, human enterovirus 71 (HEV71 and coxsackievirus A16 (CVA16 are the most common pathogens of HFMD. However, other HEVs could also cause HFMD. To rapidly detect HEV71 and CVA16, and ensure detection of all HEVs causing HFMD, two real-time hybridization probe-based RT-PCR assays were developed in this study. One is a multiplex real-time RT-PCR assay, which was developed to detect and differentiate HEV71 specifically from CVA16 directly from clinical specimens within 1-2 h, and the other is a broad-spectrum real-time RT-PCR assay, which targeted almost all HEVs. The experiments confirmed that the two assays have high sensitivity and specificity, and the sensitivity was up to 0.1 TCID50/ml for detection of HEVs, HEV71, and CVA16, respectively. A total of 213 clinical specimens were simultaneously detected by three kinds of assays, including the two real-time RT-PCR assays, direct conventional RT-PCR assay, and virus isolation assay on human rhabdomyosarcoma cells (RD cells. The total positive rate of both HEV71 and CVA16 was 69.48% with real-time RT-PCR assay, 47.42% with RT-PCR assay, and 34.58% with virus isolation assay. One HFMD clinical specimen was positive for HEV, but negative for HEV71 or CVA16, which was identified as Echovirus 11 (Echo11 by virus isolation, RT-PCR, and sequencing for the VP1 gene. The two real-time RT-PCR assays had been applied in 31 provincial HFMD labs to detect the pathogens of HFMD, which has contributed to the rapid identification of the pathogens in the early stages of HFMD outbreaks, and helped to clarify the etiologic agents of HFMD in China.

  11. Comparison of two commercial carbapenemase gene confirmatory assays in multiresistant Enterobacteriaceae and Acinetobacter baumannii-complex.

    Science.gov (United States)

    Rösner, Stephan; Gehlweiler, Kevin; Küsters, Uta; Kolbert, Mathias; Hübner, Kirsten; Pfennigwerth, Niels; Mack, Dietrich

    2018-01-01

    Multidrug-resistant Gram-negative bacilli (MDR-GNB) producing carbapenemases are increasing at an alarming speed. Rapid confirmation of carbapenemase type will be an important diagnostic step in clinical microbiology laboratories not only to reduce the risk of transmissions but also for optimising antibiotic therapy in the future. We compared diagnostic reliability of two commercially available molecular assays (Check-Direct CPE vs. AID line probe assay) for detection and typing of carbapenemase genes in 80 well-characterized isolates of MDR-GNB. Respective strains were isolated in various clinical specimens at our clinical microbiology laboratory. The reference standard included confirmation of carbapenemase-production at the molecular level at the German National Reference Laboratory for Multidrug-resistant Gram-negative bacteria (Ruhr-University Bochum, Germany). 53 Enterobacteriaceae and 27 members of the A. baumannii-complex were used in this study. The tested assays appeared highly reliable to confirm carbapenemase-producing Enterobacteriaceae (CPE) with respective sensitivities of 97.7%, but are currently unsuitable for analysis of members of the A. baumannii-complex. Both assays are easy to perform and rapid tools for confirmation and typing of the most common carbapenemase genes in Enterobacteriaceae. Implementation should be possible for any clinical microbiology laboratory with Check-Direct CPE being easier to handle and having less technological requirements.

  12. Comparison of two commercial carbapenemase gene confirmatory assays in multiresistant Enterobacteriaceae and Acinetobacter baumannii-complex.

    Directory of Open Access Journals (Sweden)

    Stephan Rösner

    Full Text Available Multidrug-resistant Gram-negative bacilli (MDR-GNB producing carbapenemases are increasing at an alarming speed. Rapid confirmation of carbapenemase type will be an important diagnostic step in clinical microbiology laboratories not only to reduce the risk of transmissions but also for optimising antibiotic therapy in the future. We compared diagnostic reliability of two commercially available molecular assays (Check-Direct CPE vs. AID line probe assay for detection and typing of carbapenemase genes in 80 well-characterized isolates of MDR-GNB. Respective strains were isolated in various clinical specimens at our clinical microbiology laboratory. The reference standard included confirmation of carbapenemase-production at the molecular level at the German National Reference Laboratory for Multidrug-resistant Gram-negative bacteria (Ruhr-University Bochum, Germany. 53 Enterobacteriaceae and 27 members of the A. baumannii-complex were used in this study. The tested assays appeared highly reliable to confirm carbapenemase-producing Enterobacteriaceae (CPE with respective sensitivities of 97.7%, but are currently unsuitable for analysis of members of the A. baumannii-complex. Both assays are easy to perform and rapid tools for confirmation and typing of the most common carbapenemase genes in Enterobacteriaceae. Implementation should be possible for any clinical microbiology laboratory with Check-Direct CPE being easier to handle and having less technological requirements.

  13. Rapid detection of microbial DNA by a novel isothermal genome exponential amplification reaction (GEAR) assay.

    Science.gov (United States)

    Prithiviraj, Jothikumar; Hill, Vincent; Jothikumar, Narayanan

    2012-04-20

    In this study we report the development of a simple target-specific isothermal nucleic acid amplification technique, termed genome exponential amplification reaction (GEAR). Escherichia coli was selected as the microbial target to demonstrate the GEAR technique as a proof of concept. The GEAR technique uses a set of four primers; in the present study these primers targeted 5 regions on the 16S rRNA gene of E. coli. The outer forward and reverse Tab primer sequences are complementary to each other at their 5' end, whereas their 3' end sequences are complementary to their respective target nucleic acid sequences. The GEAR assay was performed at a constant temperature 60 °C and monitored continuously in a real-time PCR instrument in the presence of an intercalating dye (SYTO 9). The GEAR assay enabled amplification of as few as one colony forming units of E. coli per reaction within 30 min. We also evaluated the GEAR assay for rapid identification of bacterial colonies cultured on agar media directly in the reaction without DNA extraction. Cells from E. coli colonies were picked and added directly to GEAR assay mastermix without prior DNA extraction. DNA in the cells could be amplified, yielding positive results within 15 min. Published by Elsevier Inc.

  14. Microsphere Suspension Array Assays for Detection and Differentiation of Hendra and Nipah Viruses

    Directory of Open Access Journals (Sweden)

    Adam J. Foord

    2013-01-01

    Full Text Available Microsphere suspension array systems enable the simultaneous fluorescent identification of multiple separate nucleotide targets in a single reaction. We have utilized commercially available oligo-tagged microspheres (Luminex MagPlex-TAG to construct and evaluate multiplexed assays for the detection and differentiation of Hendra virus (HeV and Nipah virus (NiV. Both these agents are bat-borne zoonotic paramyxoviruses of increasing concern for veterinary and human health. Assays were developed targeting multiple sites within the nucleoprotein (N and phosphoprotein (P encoding genes. The relative specificities and sensitivities of the assays were determined using reference isolates of each virus type, samples from experimentally infected horses, and archival veterinary diagnostic submissions. Results were assessed in direct comparison with an established qPCR. The microsphere array assays achieved unequivocal differentiation of HeV and NiV and the sensitivity of HeV detection was comparable to qPCR, indicating high analytical and diagnostic specificity and sensitivity.

  15. Diagnostic relevance of radioiron-absorption-measurements and immunoradiometric serum-ferritin-assay in the evaluation of iron stores

    International Nuclear Information System (INIS)

    Heinrich, H.C.

    1978-01-01

    Negative iron balance and enhanced iron demand respectively causes deficient iron stores (prelatent iron deficiency) with increased iron absorption, later on decrease of serum iron and increase of transferrin (latent Fe deficiency) and at least iron deficient anemia (manifest iron deficiency). In prelatend iron deficiency diagnostic 59 Fe 2+ absorption is increased and the RES cells do not show storage iron cytochemically. In latent iron deficiency in addition serum iron, transferrin iron saturation and serum ferritin is decreased and hypochromic mikrocytic anemia completes the signs of manifest iron deficiency. Besides rare cases of primary hemochromatosis and marked hyperdasia of ineffective erythropoiesis in homocygotic beta-thalassemia, hereditary non-spherocytic hemolytic anemia caused by pyruvate kinase deficiency and some sideroblastic anemias increased 59 Fe 2+ absorption is a reliable measure of exhausted iron stores. In these exceptional cases differential diagnosis between sideroachrestic and siderosensitive iron deficiency anemia can be made by measurement of serum iron and serum ferritin respectively. The etiology of iron deficiency is to be cleared by measurement of 59 Fe absorption from 59 Fe 2+ and 59 Fe-marked meat with consecutive estimation of whole body 59 Fe elimination. Shortly after completion or during oral iron therapy serum ferritin concentration is not suitable to evaluate the content of iron stores. (orig.) [de

  16. Novel Photochrome Aptamer Switch Assay (PHASA) for adaptive binding to aptamers.

    Science.gov (United States)

    Papper, Vladislav; Pokholenko, Oleksandr; Wu, Yuanyuan; Zhou, Yubin; Jianfeng, Ping; Steele, Terry W J; Marks, Robert S

    2014-11-01

    A novel Photochrome-Aptamer Switch Assay (PHASA) for the detection and quantification of small environmentally important molecules such as toxins, explosives, drugs and pollutants, which are difficult to detect using antibodies-based assays with high sensitivity and specificity, has been developed. The assay is based on the conjugation of a particular stilbene-analyte derivative to any aptamer of interest. A unique feature of the stilbene molecule is its reporting power via trans-cis photoisomerisation (from fluorescent trans-isomer to non-fluorescent cis-isomer) upon irradiation with the excitation light. The resulting fluorescence decay rate for the trans-isomer of the stilbene-analyte depends on viscosity and spatial freedom to rotate in the surrounding medium and can be used to indicate the presence of the analyte. Quantification of the assay is achieved by calibration of the fluorescence decay rate for the amount of the tested analyte. Two different formats of PHASA have been recently developed: direct conjugation and adaptive binding. New stilbene-maleimide derivatives used in the adaptive binding format have been prepared and characterised. They demonstrate effective binding to the model thiol compound and to the thiolated Malachite Green aptamer.

  17. Development of a nematode offspring counting assay for rapid and simple soil toxicity assessment.

    Science.gov (United States)

    Kim, Shin Woong; Moon, Jongmin; Jeong, Seung-Woo; An, Youn-Joo

    2018-05-01

    Since the introduction of standardized nematode toxicity assays by the American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO), many studies have reported their use. Given that the currently used standardized nematode toxicity assays have certain limitations, in this study, we examined the use of a novel nematode offspring counting assay for evaluating soil ecotoxicity based on a previous soil-agar isolation method used to recover live adult nematodes. In this new assay, adult Caenorhabditis elegans were exposed to soil using a standardized toxicity assay procedure, and the resulting offspring in test soils attracted by a microbial food source in agar plates were counted. This method differs from previously used assays in terms of its endpoint, namely, the number of nematode offspring. The applicability of the bioassay was demonstrated using metal-spiked soils, which revealed metal concentration-dependent responses, and with 36 field soil samples characterized by different physicochemical properties and containing various metals. Principal component analysis revealed that texture fraction (clay, sand, and silt) and electrical conductivity values were the main factors influencing the nematode offspring counting assay, and these findings warrant further investigation. The nematode offspring counting assay is a rapid and simple process that can provide multi-directional toxicity assessment when used in conjunction with other standard methods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. G protein-coupled receptor internalization assays in the high-content screening format.

    Science.gov (United States)

    Haasen, Dorothea; Schnapp, Andreas; Valler, Martin J; Heilker, Ralf

    2006-01-01

    High-content screening (HCS), a combination of fluorescence microscopic imaging and automated image analysis, has become a frequently applied tool to study test compound effects in cellular disease-modeling systems. This chapter describes the measurement of G protein-coupled receptor (GPCR) internalization in the HCS format using a high-throughput, confocal cellular imaging device. GPCRs are the most successful group of therapeutic targets on the pharmaceutical market. Accordingly, the search for compounds that interfere with GPCR function in a specific and selective way is a major focus of the pharmaceutical industry today. This chapter describes methods for the ligand-induced internalization of GPCRs labeled previously with either a fluorophore-conjugated ligand or an antibody directed against an N-terminal tag of the GPCR. Both labeling techniques produce robust assay formats. Complementary to other functional GPCR drug discovery assays, internalization assays enable a pharmacological analysis of test compounds. We conclude that GPCR internalization assays represent a valuable medium/high-throughput screening format to determine the cellular activity of GPCR ligands.

  19. The Comet Assay: Tails of the (Unexpected. Use of the comet assay in pharmaceutical development.

    Directory of Open Access Journals (Sweden)

    Bas-jan Van Der Leede

    2015-08-01

    Full Text Available In genotoxicity testing of pharmaceuticals the rodent alkaline comet assay is being increasingly used as a second in vivo assay in addition to the in vivo micronucleus assay to mitigate in vitro positive results as recommended by regulatory guidance. In this presentation we want to give insight into the circumstances in vivo comet assay is deployed in a Genetic Toxicology Department of a pharmaceutical company. As the in vivo comet assay is a salvage assay, it means that some events have occurred in an in vitro assay and that the compound (or metabolite responsible for this signal is potentially deselected for further development. More than often the decision to perform an in vivo comet assay is at a very early stage in development and the first time that the compound will be tested in vivo at high/toxic dose levels. As almost no toxicokinetic data and tissue distribution data are available a careful design with maximizes the chances for successful mitigation is necessary. Decisions on acute or repeated dosing need to be made and arrangements for combining the in vivo comet assay with the in vivo micronucleus assay are to be considered. Often synthesis methods need to be scaled up fast to provide the required amount of compound and information on suitable formulations needs to be in place. As exposure data is crucial for interpretation of results, analytical methods need to be brought in place rapidly. An experienced multi skilled and communicative team needs to be available to deploy successfully this kind of assays at an early stage of development. We will present a few scenarios on study conduct and demonstrate how this assay can make a difference for the further development of a new drug.

  20. Direct interaction between CD91 and C1q

    DEFF Research Database (Denmark)

    Duus, Karen; Hansen, Erik W; Tacnet, Pascale

    2010-01-01

    . C1q binding to monocytes was shown to be correlated with CD91 expression and could be inhibited by the CD91 chaperone, receptor-associated protein. We also report data showing a direct interaction between CD91 and C1q. The interaction was investigated using various protein interaction assays....... A direct interaction between purified C1q and CD91 was observed both by ELISA and a surface plasmon resonance assay, with either C1q or CD91 immobilized. The interaction showed characteristics of specificity because it was time-dependent, saturable and could be inhibited by known ligands of both CD91 and C...

  1. Evaluation of the PrimerDesign™ genesig real-time reverse transcription-polymerase chain reaction assay and the INFINITI® Respiratory Viral Panel Plus assay for the detection of human metapneumovirus in Kuwait.

    Science.gov (United States)

    Al-Turab, Mariam; Chehadeh, Wassim; Al-Mulla, Fahd; Al-Nakib, Widad

    2012-04-01

    Human metapneumovirus (hMPV) is a respiratory pathogen that was discovered in 2001 and is considered a major cause of both upper and lower respiratory tract infections. A sensitive, fast, and high-throughput diagnostic test is needed for the detection of hMPV that may assist in the clinical management as well as in the reduction of inappropriate therapy. Therefore, a comparison assessment was performed in this study between the PrimerDesign™ genesig real-time reverse transcription-polymerase chain reaction (RT-PCR) Assay and the INFINITI(®) Respiratory Viral Panel Plus Assay (RVP-Plus) for the detection of hMPV infection in patients with respiratory tract infections. A total of 200 respiratory samples were collected from 185 hospitalized patients, during the winter season in Kuwait. Of 185 patients, 10 (5.4%) were positive for hMPV RNA by the in-house RT-PCR assay, while 7 (4%) were positive for hMPV RNA by the real-time RT-PCR assay and 9 (5%) were positive for hMPV RNA by the INFINITI(®) RVP-Plus assay. The high incidence rate (60%) of hMPV infection was in January 2011. The sensitivity of the real-time RT-PCR and INFINITI(®) RVP-Plus assays was 70% and 90%, respectively, with specificity of 100% for both assays. hMPV types A and B could be identified in this study; however, discordant genotyping results were found between the direct sequencing method and the INFINITI(®) RVP-Plus assay in 33% of hMPV-positive patients. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Cell transformation assays for prediction of carcinogenic potential: state of the science and future research needs

    Science.gov (United States)

    Creton, Stuart; Aardema, Marilyn J.; Carmichael, Paul L.; Harvey, James S.; Martin, Francis L.; Newbold, Robert F.; O’Donovan, Michael R.; Pant, Kamala; Poth, Albrecht; Sakai, Ayako; Sasaki, Kiyoshi; Scott, Andrew D.; Schechtman, Leonard M.; Shen, Rhine R.; Tanaka, Noriho; Yasaei, Hemad

    2012-01-01

    Cell transformation assays (CTAs) have long been proposed as in vitro methods for the identification of potential chemical carcinogens. Despite showing good correlation with rodent bioassay data, concerns over the subjective nature of using morphological criteria for identifying transformed cells and a lack of understanding of the mechanistic basis of the assays has limited their acceptance for regulatory purposes. However, recent drivers to find alternative carcinogenicity assessment methodologies, such as the Seventh Amendment to the EU Cosmetics Directive, have fuelled renewed interest in CTAs. Research is currently ongoing to improve the objectivity of the assays, reveal the underlying molecular changes leading to transformation and explore the use of novel cell types. The UK NC3Rs held an international workshop in November 2010 to review the current state of the art in this field and provide directions for future research. This paper outlines the key points highlighted at this meeting. PMID:21852270

  3. The assay of glucocerebrosidase activity using the natural substrate

    International Nuclear Information System (INIS)

    Strasberg, P.M.; Lowden, J.A.

    1982-01-01

    The authors have examined eight published methods for the assay of glucocerebrosidase using the natural substrate glucocerebroside and tabulated the variable components and conditions while comparing these methods to their own. In each case assays were performed using a 8000 fold, partially purified human placental enzyme, having a pH optimum of 5.4-5.6 and a Ksub(m) of approximately 0.60 mmol per liter. Results were obtained by following the release of radioactive ceramide or of unlabelled glucose. In many cases published results had been based on a one- or two-hour incubation time. Apparent specific activities varied over a 70-fold difference between the various procedures. When the authors measured activities from the linear (15-30 min) portion of rate curves the values increased by 1.4 to 3 times but still ranged from 6x10 3 -180x10 3 nmol. mg -1 protein h -1 . They obtained maximum velocity using 1.2 mmol glucocerebroside, 0.5% (w/v) crude taurocholate and 2 μg enzyme protein/ml. Specific activities reported from different laboratories are not directly comparable. Conditions for assay should be optimized for the enzyme preparation to be studied. (Auth.)

  4. Evaluation of the BD Max Cdiff assay for the detection of toxigenic Clostridium difficile in human stool specimens.

    Science.gov (United States)

    Putsathit, Papanin; Morgan, Justin; Bradford, Damien; Engelhardt, Nelly; Riley, Thomas V

    2015-02-01

    The Becton Dickinson (BD) PCR-based GeneOhm Cdiff assay has demonstrated a high sensitivity and specificity for detecting Clostridium difficile. Recently, the BD Max platform, using the same principles as BD GeneOhm, has become available in Australia. This study aimed to investigate the sensitivity and specificity of BD Max Cdiff assay for the detection of toxigenic C. difficile in an Australian setting. Between December 2013 and January 2014, 406 stool specimens from 349 patients were analysed with the BD Max Cdiff assay. Direct and enrichment toxigenic culture were performed on bioMérieux ChromID C. difficile agar as a reference method. isolates from specimens with discrepant results were further analysed with an in-house PCR to detect the presence of toxin genes. The overall prevalence of toxigenic C. difficile was 7.2%. Concordance between the BD Max assay and enrichment culture was 98.5%. The sensitivity, specificity, positive predictive value and negative predictive value for the BD Max Cdiff assay were 95.5%, 99.0%, 87.5% and 99.7%, respectively, when compared to direct culture, and 91.7%, 99.0%, 88.0% and 99.4%, respectively, when compared to enrichment culture. The new BD Max Cdiff assay appeared to be an excellent platform for rapid and accurate detection of toxigenic C. difficile.

  5. Direct analysis of quantal radiation response data

    International Nuclear Information System (INIS)

    Thames, H.D. Jr.; Rozell, M.E.; Tucker, S.L.; Ang, K.K.; Travis, E.L.; Fisher, D.R.

    1986-01-01

    A direct analysis is proposed for quantal (all-or-nothing) responses to fractionated radiation and endpoint-dilution assays of cell survival. As opposed to two-step methods such as the reciprocal-dose technique, in which ED 50 values are first estimated for different fractionation schemes and then fit (as reciprocals) against dose per fraction, all raw data are included in a single maximum-likelihood treatment. The method accommodates variations such as short-interval fractionation regimens designed to determine tissue repair kinetics, tissue response to continuous exposures, and data obtained using endpoint-dilution assays of cell survival after fractionated doses. Monte-Carlo techniques were used to compare the direct and reciprocal-dose methods for analysis of small-scale and large-scale studies of response to fractionated doses. Both methods tended toward biased estimates in the analysis of small-scale (3 fraction numbers) studies. The α/β ratios showed less scatter when estimated by the direct method. The 95% confidence intervals determined by the direct method were more appropriate than those determined by reciprocal-dose analysis, for which 18% (small-scale study) or 8% (large-scale study) of the confidence intervals did not include the 'true' value of α/β. (author)

  6. Relationship between the radioisotopic footpad assay and other immunological assays in tumor bearing rats

    International Nuclear Information System (INIS)

    Mizushima, Yutaka; Takeichi, Noritoshi; Minami, Akio; Kasai, Masaharu; Itaya, Toshiyuki

    1981-01-01

    KMT-17, a fibrosarcoma induced by 3-methylcholanthrene in a WKA rat, is a sensitive tumor to various kinds of immunological assays and is a suitable model tumor for the study of the immune status in tumor bearing hosts. The antitumor immune response of KMT-17 bearing rats was studied by a radioisotopic footpad assay (FPA) in comparison with other in vivo and in vitro assays. Delayed hypersensitivity to tumor antigens measured by the FPA was observed from the 8th day after transplantation of KMT-17 cells, reached a peak on the 12 - 15th day, and then declined in the late stage on the 17th day. The kinetics of the FPA correlated well with those of an in vivo Winn assay and of an in vitro lymphocyte cytotoxicity assay ( 51 Cr-release assay). The appearance of an antitumor antibody detected by a complement dependent cytotoxicity test also correlated well with the kinetics of the FPA. A growth inhibition assay (GIA) for non-specific cell-mediated immunity also showed similar kinetics to that of the FPA. The delayed hypersensitivity footpad reaction to tumor cell extracts measured by this FPA was tumor-specific. These results suggest that the FPA is a simple and reliable in vivo assay for evaluating antitumor immunity in tumor bearing hosts. (author)

  7. Liquor oligoclonal bands assay: interpretation, correlation with other laboratory assays and importance for diagnostics of neurological disorders

    OpenAIRE

    Bagdonas, Dovydas

    2017-01-01

    Aim: to analyse the possible relationship between liquor IgG oligoclonal bands assay and other laboratory assays in neurological patients. Objectives: to determine the frequency of oligoclonal bands in neurological patients; to compare the results between serum and liquor laboratory assays in dependence of oligoclonal bands assay results; to evaluate the relationships between oligoclonal bands assay and serological-immunological assays for infectious diseases, gender, age and neurological ...

  8. Temperature Switch PCR (TSP: Robust assay design for reliable amplification and genotyping of SNPs

    Directory of Open Access Journals (Sweden)

    Mather Diane E

    2009-12-01

    Full Text Available Abstract Background Many research and diagnostic applications rely upon the assay of individual single nucleotide polymorphisms (SNPs. Thus, methods to improve the speed and efficiency for single-marker SNP genotyping are highly desirable. Here, we describe the method of temperature-switch PCR (TSP, a biphasic four-primer PCR system with a universal primer design that permits amplification of the target locus in the first phase of thermal cycling before switching to the detection of the alleles. TSP can simplify assay design for a range of commonly used single-marker SNP genotyping methods, and reduce the requirement for individual assay optimization and operator expertise in the deployment of SNP assays. Results We demonstrate the utility of TSP for the rapid construction of robust and convenient endpoint SNP genotyping assays based on allele-specific PCR and high resolution melt analysis by generating a total of 11,232 data points. The TSP assays were performed under standardised reaction conditions, requiring minimal optimization of individual assays. High genotyping accuracy was verified by 100% concordance of TSP genotypes in a blinded study with an independent genotyping method. Conclusion Theoretically, TSP can be directly incorporated into the design of assays for most current single-marker SNP genotyping methods. TSP provides several technological advances for single-marker SNP genotyping including simplified assay design and development, increased assay specificity and genotyping accuracy, and opportunities for assay automation. By reducing the requirement for operator expertise, TSP provides opportunities to deploy a wider range of single-marker SNP genotyping methods in the laboratory. TSP has broad applications and can be deployed in any animal and plant species.

  9. Immunocapture loop-mediated isothermal amplification assays for the detection of canine parvovirus.

    Science.gov (United States)

    Sun, Yu-Ling; Yen, Chon-Ho; Tu, Ching-Fu

    2017-11-01

    A loop-mediated isothermal amplification (LAMP) assay was used for rapid canine parvovirus (CPV) diagnosis. To reduce the time required and increase the sensitivity of the assay, an immunocapture (IC) technique was developed in this study to exclude the DNA extraction step in molecular diagnostic procedures for CPV. A polyclonal rabbit anti-CPV serum was produced against VP2-EpC that was cloned via DNA recombination. The polyclonal anti-VP2-EpC serum was used for virus capture to prepare microtubes. IC-LAMP was performed to amplify a specific CPV target gene sequence from the CPV viral particles that were captured on the microtubes, and the amplicons were analyzed using agarose electrophoresis or enzyme-linked immunosorbent assay (IC-LAMP-ELISA) and lateral-flow dipstick (IC-LAMP-LFD). The detection sensitivities of IC-LAMP, IC-LAMP-ELISA, and IC-LAMP-LFD were 10 -1 , 10 -1 , and 10 -1 TCID 50 /mL, respectively. Using the IC-LAMP-ELISA and IC-LAMP-LFD assays, the complete CPV diagnostic process can be achieved within 1.5h. Both of the developed IC-LAMP-based assays are simple, direct visual and efficient techniques that are applicable to the detection of CPV. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Limitations of Chromogranin A in clinical practice.

    Science.gov (United States)

    Marotta, Vincenzo; Nuzzo, Vincenzo; Ferrara, Teresa; Zuccoli, Alfonso; Masone, Milena; Nocerino, Lorenzo; Del Prete, Michela; Marciello, Francesca; Ramundo, Valeria; Lombardi, Gaetano; Vitale, Mario; Colao, Annamaria; Faggiano, Antongiulio

    2012-03-01

    Usefulness of circulating Chromogranin A (CgA) for the diagnosis of neuroendocrine tumors (NEN) is controversial. The aim of the present study was to assess the actual role of this marker as diagnostic tool. Serum blood samples were obtained from 42 subjects affected with NEN, 120 subjects affected with non-endocrine neoplasias (non-NEN) and 100 non-neoplastic subjects affected with benign nodular goitre (NNG). Determination of CgA was performed by means of immunoradiometric assay. The CgA levels among NEN-patients were not significantly different from NNG and non-NEN subjects. The Receiver operating characteristic (ROC) curves analysis failed to identify a feasible cut-off value for the differential diagnosis between NEN and the other conditions. Serum CgA is not helpful for the first-line diagnosis of NEN.

  11. Endogenous Locus Reporter Assays.

    Science.gov (United States)

    Liu, Yaping; Hermes, Jeffrey; Li, Jing; Tudor, Matthew

    2018-01-01

    Reporter gene assays are widely used in high-throughput screening (HTS) to identify compounds that modulate gene expression. Traditionally a reporter gene assay is built by cloning an endogenous promoter sequence or synthetic response elements in the regulatory region of a reporter gene to monitor transcriptional activity of a specific biological process (exogenous reporter assay). In contrast, an endogenous locus reporter has a reporter gene inserted in the endogenous gene locus that allows the reporter gene to be expressed under the control of the same regulatory elements as the endogenous gene, thus more accurately reflecting the changes seen in the regulation of the actual gene. In this chapter, we introduce some of the considerations behind building a reporter gene assay for high-throughput compound screening and describe the methods we have utilized to establish 1536-well format endogenous locus reporter and exogenous reporter assays for the screening of compounds that modulate Myc pathway activity.

  12. ABTS assay of phenol oxidase activity in soil.

    Science.gov (United States)

    Floch, Carine; Alarcon-Gutiérrez, Enrique; Criquet, Stéven

    2007-12-01

    Phenol oxidases (PO) are involved in degradation of many recalcitrant aromatic compounds and may be sensitive to some pollutants. Hence, their activities may be a useful indicator for evaluating soil quality and health. To this end, the aim of this study was to develop a simple method to assay PO activity directly in bulk samples by spectrophotometric test using 2,2'-azinobis-(-3 ethylbenzothiazoline-6-sulfononic acid) diammonium salt (ABTS) as the substrate. Three Mediterranean soils were used as models. For each soil, we studied the kinetic parameters and the effects of certain factors (i.e. amount of soil, pH, temperature, incubation time and substrate concentration) in order to determine the optimum conditions for the ABTS assay. Results showed that PO attain their optimum activities when incubating 0.1 g of soil at 30 degrees C for 5 min with 10 ml of a Modified Universal Buffer (MUB) at pH 2 and 200 microl of a 0.1 M ABTS solution.

  13. A real-time loop-mediated isothermal amplification assay for rapid detection of Shigella species.

    Science.gov (United States)

    Liew, P S; Teh, C S J; Lau, Y L; Thong, K L

    2014-12-01

    Shigellosis is a foodborne illness caused by the genus Shigella and is an important global health issue. The development of effective techniques for rapid detection of this pathogen is essential for breaking the chain of transmission. Therefore, we have developed a novel loop-mediated isothermal amplification (LAMP) assay targeting the invasion plasmid antigen H (ipaH) gene to rapidly detect Shigella species. This assay could be performed in 90 min at an optimal temperature of 64ºC, with endpoint results visualized directly. Notably, the method was found to be more sensitive than conventional PCR. Indeed, the detection limit for the LAMP assay on pure bacterial cultures was 5.9 x 10(5) CFU/ml, while PCR displayed a limit of 5.9 x 10(7) CFU/ml. In spiked lettuce samples, the sensitivity of the LAMP assay was 3.6 x 10(4) CFU/g, whereas PCR was 3.6 x 10(5) CFU/g. Overall, the assay accurately identified 32 Shigella spp. with one enteroinvasive Escherichia coli displaying positive reaction while the remaining 32 non-Shigella strains tested were negative.

  14. Co-incubation with IL-18 potentiates antigen-specific IFN-γ response in a whole-blood stimulation assay for measurement of cell-mediated immune responses in pigs experimentally infected with Lawsonia intracellularis

    DEFF Research Database (Denmark)

    Riber, Ulla; Boesen, Henriette Toft; Jakobsen, Jeanne Toft

    2011-01-01

    The whole-blood interferon-gamma (IFN-γ) assay is a quantitative in-vitro assay for a direct read out of Ag-specific cell-mediated immune (CMI) responses to infectious diseases. The IFN-γ assay is robust in severe intracellular infections like Brucella or mycobacteria, but more difficult to evalu......The whole-blood interferon-gamma (IFN-γ) assay is a quantitative in-vitro assay for a direct read out of Ag-specific cell-mediated immune (CMI) responses to infectious diseases. The IFN-γ assay is robust in severe intracellular infections like Brucella or mycobacteria, but more difficult...

  15. Bioactivity and immunoactivity of growth hormone during dynamic testing of patients with acromegaly

    International Nuclear Information System (INIS)

    Baldwin, A.L.; Norman, M.; Butler, J.; Aston, R.; Buchanan, C.

    1988-01-01

    We have used the Nb2 cell proliferation bioassay for lactogenic hormones to investigate the biological activity of hGH in sera of patients with acromegaly. The specificity of the assay has been improved by the use of monoclonal antibodies to block the activity of individual lactogenic hormones. Disease activity in patients was assessed by scoring signs and symptoms, and by measuring IGF-I concentrations in some patients. Patients with a wide spectrum of disease activity were studied using a TRH test. hGH concentrations were measured by bioassay, RIA and immunoradiometric assay (IRMA) at 0,20 and 60 min after injection of TRH. There was a high degree of correlation between log 10 of all hGH concentrations measured by bioassay and RIA (r = 0.995, P<0.0001), between bioassay and IRMA (r = 0.990, P<0.0001), and between RIA and IRMA (r = 0.995, P<0.0001). In contrast to previous reports, we found no evidence for changes in the bioactivity of hGH secreted after pituitary stimulation. (author)

  16. Percentage of free serum prostate-specific antigen: a new tool in the early diagnosis of prostatic cancer.

    Science.gov (United States)

    Toubert, M E; Guillet, J; Chiron, M; Meria, P; Role, C; Schlageter, M H; Francois, H; Borschneck, C; Nivelon, F; Desgrandchamps, F; Rastel, D; Cussenot, O; Teillac, P; Le Duc, A; Najean, Y

    1996-11-01

    Prostate-specific antigen (PSA) is a protease able to bind to serum antiproteases as alpha 1 antichymotrypsin (ACT). Free PSA (FPSA) corresponds to the fraction of total PSA (TPSA) which is unbound to ACT. Specific detection of the FPSA seems to be a valuable tool in the distinction between prostatic cancer (PCa) and benign prostatic hyperplasia (BPH). Our aim was to evaluate retrospectively the FPSA/TPSA ratio in comparison to TPSA or FPSA determination, using two new immunoradiometric assays (PSA-RIACT and FPSA-RIACT, CIS bio international, Gif Sur Yvette, France) in the early diagnosis of PCa. 256 men, with TPSA levels between 0.7 and 44.7 ng/ml (median age = 69 years), including 164 sera obtained from patients with BPH and 92 sera from patients with untreated PCa were assayed. All diagnoses were histologically confirmed and patients tested before any adjuvant treatment. The evaluation of the median FPSA/TPSA ratio in the two groups showed significantly different values (BPH group: 24.2%, PCa group: 12.1%, P 10 ng/ml).

  17. Lead Slowing-Down Spectrometry for Spent Fuel Assay: FY11 Status Report

    International Nuclear Information System (INIS)

    Warren, Glen A.; Casella, Andrew M.; Haight, R.C.; Anderson, Kevin K.; Danon, Yaron; Hatchett, D.; Becker, Bjorn; Devlin, M.; Imel, G.R.; Beller, D.; Gavron, A.; Kulisek, Jonathan A.; Bowyer, Sonya M.; Gesh, Christopher J.; O'Donnell, J.M.

    2011-01-01

    Executive Summary Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R and D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration to study the feasibility of Lead Slowing Down Spectroscopy (LSDS). This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today's confirmatory assay methods. This document is a progress report for FY2011 collaboration activities. Progress made by the collaboration in FY2011 continues to indicate the promise of LSDS techniques applied to used fuel. PNNL developed an empirical model based on calibration of the LSDS to responses generated from well-characterized used fuel. The empirical model demonstrated the potential for the direct and independent assay of the sum of the masses of 239Pu and 241Pu to within approximately 3% over a wide used fuel parameter space. Similar results were obtained using a perturbation approach developed by LANL. Benchmark measurements have been successfully conducted at LANL and at RPI using their respective LSDS instruments. The ISU and UNLV collaborative effort is focused on the fabrication and testing of prototype fission chambers lined with ultra-depleted 238U and 232Th, and uranium deposition on a stainless steel disc using spiked U3O8 from room temperature ionic liquid was successful, with improving thickness obtained. In FY2012, the collaboration plans a broad array of activities. PNNL will focus on optimizing its empirical model and minimizing its reliance on calibration data, as well continuing efforts on developing an analytical model. Additional measurements are

  18. Six rapid tests for direct detection of Clostridium difficile and its toxins in fecal samples compared with the fibroblast cytotoxicity assay.

    Science.gov (United States)

    Turgeon, David K; Novicki, Thomas J; Quick, John; Carlson, LaDonna; Miller, Pat; Ulness, Bruce; Cent, Anne; Ashley, Rhoda; Larson, Ann; Coyle, Marie; Limaye, Ajit P; Cookson, Brad T; Fritsche, Thomas R

    2003-02-01

    Clostridium difficile is one of the most frequent causes of nosocomial gastrointestinal disease. Risk factors include prior antibiotic therapy, bowel surgery, and the immunocompromised state. Direct fecal analysis for C. difficile toxin B by tissue culture cytotoxin B assay (CBA), while only 60 to 85% sensitive overall, is a common laboratory method. We have used 1,003 consecutive, nonduplicate fecal samples to compare six commercially available immunoassays (IA) for C. difficile detection with CBA: Prima System Clostridium difficile Tox A and VIDAS Clostridium difficile Tox A II, which detect C. difficile toxin A; Premier Cytoclone A/B and Techlab Clostridium difficile Tox A/B, which detect toxins A and B; and ImmunoCard Clostridium difficile and Triage Micro C. difficile panels, which detect toxin A and a species-specific antigen. For all tests, Triage antigen was most sensitive (89.1%; negative predictive value [NPV] = 98.7%) while ImmunoCard was most specific (99.7%; positive predictive value [PPV] = 95.0%). For toxin tests only, Prima System had the highest sensitivity (82.2%; NPV = 98.0%) while ImmunoCard had the highest specificity (99.7%; PPV = 95.0%). Hematopoietic stem cell transplant (HSCT) patients contributed 44.7% of all samples tested, and no significant differences in sensitivity or specificity were noted between HSCT and non-HSCT patients. IAs, while not as sensitive as direct fecal CBA, produce reasonable predictive values, especially when both antigen and toxin are detected. They also offer significant advantages over CBA in terms of turnaround time and ease of use.

  19. ELISPOT Assay for Monitoring Cytotoxic T Lymphocytes (CTL Activity in Cancer Vaccine Clinical Trials

    Directory of Open Access Journals (Sweden)

    Thomas J. Sayers

    2012-05-01

    Full Text Available The profiling and monitoring of immune responses are key elements in the evaluation of the efficacy and development of new biotherapies, and a number of assays have been introduced for analyzing various immune parameters before, during, and after immunotherapy. The choice of immune assays for a given clinical trial depends on the known or suggested immunomodulating mechanisms associated with the tested therapeutic modality. Cell-mediated cytotoxicity represents a key mechanism in the immune response to various pathogens and tumors. Therefore, the selection of monitoring methods for the appropriate assessment of cell-mediated cytotoxicity is thought to be crucial. Assays that can detect both cytotoxic T lymphocytes (CTL frequency and function, such as the IFN-γ enzyme-linked immunospot assay (ELISPOT have gained increasing popularity for monitoring clinical trials and in basic research. Results from various clinical trials, including peptide and whole tumor cell vaccination and cytokine treatment, have shown the suitability of the IFN-γ ELISPOT assay for monitoring T cell responses. However, the Granzyme B ELISPOT assay and Perforin ELISPOT assay may represent a more direct analysis of cell-mediated cytotoxicity as compared to the IFN-γ ELISPOT, since Granzyme B and perforin are the key mediators of target cell death via the granule-mediated pathway. In this review we analyze our own data and the data reported by others with regard to the application of various modifications of ELISPOT assays for monitoring CTL activity in clinical vaccine trials.

  20. Polymerase chain reaction assay for the detection of Bacillus cereus group cells

    DEFF Research Database (Denmark)

    Hansen, Bjarne Munk; Leser, Thomas D.; Hendriksen, Niels Bohse

    2001-01-01

    of the B. cereus group in food and in the environment. Using 16S rDNA as target, a PCR assay for the detection of B. cereus group cells has been developed. Primers specific for the 16S rDNA of the B. cereus group bacteria were selected and used in combination with consensus primers for 165 rDNA as internal...... PCR procedure control. The PCR procedure was optimized with respect to annealing temperature. When DNA from the B. cereus group bacteria was present, the PCR assay yielded a B. cereus specific fragment, while when non-B. cereus prokaryotic DNA was present, the consensus 165 rDNA primers directed...

  1. Absolute nuclear material assay

    Science.gov (United States)

    Prasad, Manoj K [Pleasanton, CA; Snyderman, Neal J [Berkeley, CA; Rowland, Mark S [Alamo, CA

    2010-07-13

    A method of absolute nuclear material assay of an unknown source comprising counting neutrons from the unknown source and providing an absolute nuclear material assay utilizing a model to optimally compare to the measured count distributions. In one embodiment, the step of providing an absolute nuclear material assay comprises utilizing a random sampling of analytically computed fission chain distributions to generate a continuous time-evolving sequence of event-counts by spreading the fission chain distribution in time.

  2. Direct immunofluorescence assay compared to cell culture for the diagnosis of mucocutaneous herpes simplex virus infections in children.

    Science.gov (United States)

    Caviness, A Chantal; Oelze, Lindsay L; Saz, Ulas E; Greer, Jewel M; Demmler-Harrison, Gail J

    2010-09-01

    Direct immunofluorescence assay (DFA) is commonly used for the rapid identification of herpes simplex virus (HSV) infection in mucocutaneous lesions, yet little is known about its diagnostic accuracy. To determine the diagnostic yield and accuracy of HSV DFA for the diagnosis of mucocutaneous HSV infection in pediatric patients. Retrospective cross-sectional study of all patients who underwent HSV DFA testing by the Texas Children's Hospital Diagnostic Virology between January 1, 1995 and December 31, 2005. HSV DFA sensitivity, specificity, positive likelihood ratio (LRs), and negative LRs were estimated using viral culture as the reference standard. 659 specimens were submitted for HSV DFA with concurrent viral cultures. Viral cultures were positive for HSV type 1 in 158 (24%) and HSV type 2 in 2 (0.3%). There were 433 different patients with a median age of 8.6 years. Types of lesions were as follows: 50% ulcerative, 26% vesicular, 8% erythema or purpura, 5% pustular, and 11% missing. Of the 659 specimens submitted for HSV DFA, 160 (24%) were inconclusive due to inadequate cells. Of the 499 adequate specimens, overall HSV DFA test accuracy was: sensitivity 61%, specificity 99%, LR positive 40, and LR negative 0.39. A quarter of specimens submitted for HSV DFA testing are not adequate for DFA testing. When HSV DFA can be performed, it is specific, but not sensitive, for the identification of mucocutaneous HSV infection in children. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  3. Assay method and compositions

    International Nuclear Information System (INIS)

    1977-01-01

    Methods are described for measuring catecholamine levels in human and animal body fluids and tissues using the catechol-O-methyl-transferase (COMT) radioassay. The assay involves incubating the biological sample with COMT and the tritiated methyl donor, S-adenosyl-L-methionine( 3 H)-methyl. The O-methylated ( 3 H) epinephrine and/or norepinephrine are extracted and oxidised to vanillin- 3 H which in turn is extracted and its radioactivity counted. When analysing dopamine levels the assay is extended by vanillin- 3 H and raising the pH of the aqueous periodate phase from which O-methylated ( 3 H) dopamine is extracted and counted. The assay may be modified depending on whether measurements of undifferentiated total endogenous catecholamine levels or differential analyses of the catecholamine levels are being performed. The sensitivity of the assay can be as low as 5 picograms for norepinephrine and epinephrine and 12 picograms for dopamine. The assemblance of the essential components of the assay into a kit for use in laboratories is also described. (U.K.)

  4. Analysis of JC virus DNA replication using a quantitative and high-throughput assay

    International Nuclear Information System (INIS)

    Shin, Jong; Phelan, Paul J.; Chhum, Panharith; Bashkenova, Nazym; Yim, Sung; Parker, Robert; Gagnon, David; Gjoerup, Ole; Archambault, Jacques; Bullock, Peter A.

    2014-01-01

    Progressive Multifocal Leukoencephalopathy (PML) is caused by lytic replication of JC virus (JCV) in specific cells of the central nervous system. Like other polyomaviruses, JCV encodes a large T-antigen helicase needed for replication of the viral DNA. Here, we report the development of a luciferase-based, quantitative and high-throughput assay of JCV DNA replication in C33A cells, which, unlike the glial cell lines Hs 683 and U87, accumulate high levels of nuclear T-ag needed for robust replication. Using this assay, we investigated the requirement for different domains of T-ag, and for specific sequences within and flanking the viral origin, in JCV DNA replication. Beyond providing validation of the assay, these studies revealed an important stimulatory role of the transcription factor NF1 in JCV DNA replication. Finally, we show that the assay can be used for inhibitor testing, highlighting its value for the identification of antiviral drugs targeting JCV DNA replication. - Highlights: • Development of a high-throughput screening assay for JCV DNA replication using C33A cells. • Evidence that T-ag fails to accumulate in the nuclei of established glioma cell lines. • Evidence that NF-1 directly promotes JCV DNA replication in C33A cells. • Proof-of-concept that the HTS assay can be used to identify pharmacological inhibitor of JCV DNA replication

  5. Analysis of JC virus DNA replication using a quantitative and high-throughput assay

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Jong; Phelan, Paul J.; Chhum, Panharith; Bashkenova, Nazym; Yim, Sung; Parker, Robert [Department of Developmental, Molecular and Chemical Biology, Tufts University School of Medicine, Boston, MA 02111 (United States); Gagnon, David [Institut de Recherches Cliniques de Montreal (IRCM), 110 Pine Avenue West, Montreal, Quebec, Canada H2W 1R7 (Canada); Department of Biochemistry and Molecular Medicine, Université de Montréal, Montréal, Quebec (Canada); Gjoerup, Ole [Molecular Oncology Research Institute, Tufts Medical Center, Boston, MA 02111 (United States); Archambault, Jacques [Institut de Recherches Cliniques de Montreal (IRCM), 110 Pine Avenue West, Montreal, Quebec, Canada H2W 1R7 (Canada); Department of Biochemistry and Molecular Medicine, Université de Montréal, Montréal, Quebec (Canada); Bullock, Peter A., E-mail: Peter.Bullock@tufts.edu [Department of Developmental, Molecular and Chemical Biology, Tufts University School of Medicine, Boston, MA 02111 (United States)

    2014-11-15

    Progressive Multifocal Leukoencephalopathy (PML) is caused by lytic replication of JC virus (JCV) in specific cells of the central nervous system. Like other polyomaviruses, JCV encodes a large T-antigen helicase needed for replication of the viral DNA. Here, we report the development of a luciferase-based, quantitative and high-throughput assay of JCV DNA replication in C33A cells, which, unlike the glial cell lines Hs 683 and U87, accumulate high levels of nuclear T-ag needed for robust replication. Using this assay, we investigated the requirement for different domains of T-ag, and for specific sequences within and flanking the viral origin, in JCV DNA replication. Beyond providing validation of the assay, these studies revealed an important stimulatory role of the transcription factor NF1 in JCV DNA replication. Finally, we show that the assay can be used for inhibitor testing, highlighting its value for the identification of antiviral drugs targeting JCV DNA replication. - Highlights: • Development of a high-throughput screening assay for JCV DNA replication using C33A cells. • Evidence that T-ag fails to accumulate in the nuclei of established glioma cell lines. • Evidence that NF-1 directly promotes JCV DNA replication in C33A cells. • Proof-of-concept that the HTS assay can be used to identify pharmacological inhibitor of JCV DNA replication.

  6. Validity of urinary monoamine assay sales under the "spot baseline urinary neurotransmitter testing marketing model".

    Science.gov (United States)

    Hinz, Marty; Stein, Alvin; Uncini, Thomas

    2011-01-01

    Spot baseline urinary monoamine assays have been used in medicine for over 50 years as a screening test for monoamine-secreting tumors, such as pheochromocytoma and carcinoid syndrome. In these disease states, when the result of a spot baseline monoamine assay is above the specific value set by the laboratory, it is an indication to obtain a 24-hour urine sample to make a definitive diagnosis. There are no defined applications where spot baseline urinary monoamine assays can be used to diagnose disease or other states directly. No peer-reviewed published original research exists which demonstrates that these assays are valid in the treatment of individual patients in the clinical setting. Since 2001, urinary monoamine assay sales have been promoted for numerous applications under the "spot baseline urinary neurotransmitter testing marketing model". There is no published peer-reviewed original research that defines the scientific foundation upon which the claims for these assays are made. On the contrary, several articles have been published that discredit various aspects of the model. To fill the void, this manuscript is a comprehensive review of the scientific foundation and claims put forth by laboratories selling urinary monoamine assays under the spot baseline urinary neurotransmitter testing marketing model.

  7. Evaluation of a Noncontact, Alternative Mosquito Repellent Assay System.

    Science.gov (United States)

    Tisgratog, Rungarun; Kongmee, Monthathip; Sanguanpong, Unchalee; Prabaripai, Atchariya; Bangs, Michael J; Chareonviriyaphap, Theeraphap

    2016-09-01

    A novel noncontact repellency assay system (NCRAS) was designed and evaluated as a possible alternative method for testing compounds that repel or inhibit mosquitoes from blood feeding. Deet and Aedes aegypti were used in a controlled laboratory setting. Using 2 study designs, a highly significant difference were seen between deet-treated and untreated skin placed behind the protective screens, indicating that deet was detected and was acting as a deterrence to mosquito landing and probing behavior. However, a 2nd study showed significant differences between protected (behind a metal screen barrier) and unprotected (exposed) deet-treated forearms, indicating the screen mesh might restrict the detection of deet and thus influences landing/biting response. These findings indicate the prototype NCRAS shows good promise but requires further evaluation and possible modification in design and testing protocol to achieve more desirable operational attributes in comparison with direct skin-contact repellency mosquito assays.

  8. A novel method for direct measurement of complement convertases activity in human serum.

    Science.gov (United States)

    Blom, A M; Volokhina, E B; Fransson, V; Strömberg, P; Berghard, L; Viktorelius, M; Mollnes, T E; López-Trascasa, M; van den Heuvel, L P; Goodship, T H; Marchbank, K J; Okroj, M

    2014-10-01

    Complement convertases are enzymatic complexes that play a central role in sustaining and amplification of the complement cascade. Impairment of complement function leads directly or indirectly to pathological conditions, including higher infection rate, kidney diseases, autoimmune- or neurodegenerative diseases and ischaemia-reperfusion injury. An assay for direct measurement of activity of the convertases in patient sera is not available. Existing assays testing convertase function are based on purified complement components and, thus, convertase formation occurs under non-physiological conditions. We designed a new assay, in which C5 blocking compounds enabled separation of the complement cascade into two phases: the first ending at the stage of C5 convertases and the second ending with membrane attack complex formation. The use of rabbit erythrocytes or antibody-sensitized sheep erythrocytes as the platforms for convertase formation enabled easy readout based on measurement of haemolysis. Thus, properties of patient sera could be studied directly regarding convertase activity and membrane attack complex formation. Another advantage of this assay was the possibility to screen for host factors such as C3 nephritic factor and other anti-complement autoantibodies, or gain-of-function mutations, which prolong the half-life of complement convertases. Herein, we present proof of concept, detailed description and validation of this novel assay. © 2014 British Society for Immunology.

  9. Direct LAMP Assay without Prior DNA Purification for Sex Determination of Papaya

    Directory of Open Access Journals (Sweden)

    Chi-Chu Tsai

    2016-09-01

    Full Text Available Papaya (Carica papaya L. is an economically important tropical fruit tree with hermaphrodite, male and female sex types. Hermaphroditic plants are the major type used for papaya production because their fruits have more commercial advantages than those of female plants. Sex determination of the seedlings, or during the early growth stages, is very important for the papaya seedling industry. Thus far, the only method for determining the sex type of a papaya at the seedling stage has been DNA analysis. In this study, a molecular technique—based on DNA analysis—was developed for detecting male-hermaphrodite-specific markers to examine the papaya’s sex type. This method is based on the loop-mediated isothermal amplification (LAMP and does not require prior DNA purification. The results show that the method is an easy, efficient, and inexpensive way to determine a papaya’s sex. This is the first report on the LAMP assay, using intact plant materials-without DNA purification-as samples for the analysis of sex determination of papaya. We found that using high-efficiency DNA polymerase was essential for successful DNA amplification, using trace intact plant material as a template DNA source.

  10. Performance of the Abbott RealTime MTB RIF/INH resistance assay when used to test Mycobacterium tuberculosis specimens from Bangladesh

    Directory of Open Access Journals (Sweden)

    Kostera J

    2018-05-01

    Full Text Available Joshua Kostera, Gregor Leckie, Klara Abravaya, Hong Wang Abbott Molecular, Abbott Laboratories, Des Plaines, IL, USA Introduction: The Abbott RealTime MTB RIF/INH Resistance Assay (RT MTB RIF/INH is an assay for the detection of rifampicin (RIF- and/or isoniazid (INH-resistant Mycobacterium tuberculosis (MTB. The assay can be used to test sputum, bronchial alveolar lavage, and N-Acetyl-L-Cysteine (NALC/NaOH pellets prepared from these samples. The assay can be used in direct testing mode, or in reflex mode following a MTB positive result produced by its companion assay, Abbott RT MTB. Methods: In this study, the direct testing mode was used to test paired sputum and NALC/NaOH pellets prepared from sputum collected from Bangladesh TB patients. One hundred and thirty two paired samples were tested. Results: The RT MTB RIF/INH inhibition rate was 0%. One hundred and twenty-two paired samples had results above the assay limit of detection and were analyzed by comparing with results from phenotypic drug sensitivity testing, GeneXpert MTB/RIF (Xpert, and MTBDR plus (Hain. RT MTB RIF/INH results were in good agreement with those of GeneXpert and Hain. Conclusion: The ability of this assay to detect RIF and INH resistance may contribute to the global control of multidrug resistant tuberculosis. Keywords: tuberculosis, rifampicin, isoniazid, resistance

  11. Diagnostic significance of tumor markers CEA, CA50 and CA19-9 for colorectal cancer

    International Nuclear Information System (INIS)

    Chen Yumei; Huang Gang

    2005-01-01

    Objective: To investigate the expression and diagnostic significance of three serum tumor markers (CEA, CA50, CA19-9) in patients with colorectal cancer, with special emphasis on their combined assay. Methods: Serum CEA, CA19-9 levels (with chemiluminescence immunoassay) and CA50 levels (with immunoradiometric assay) were determined in 94 patients with colorectal cancer, 20 patients with benign colorectal disorders and 37 controls. Results: The expressions of the serum tumor markers were significantly higher in patients with colorectal cancer than those in patients with benign colorectal disorders and controls (P<0.05). There was no significant difference between the levels in the latter two groups. CEA assay had the highest sensitivity (57.4%) and specificity (85.9%). Combined assay of the three could enhance both the sensitivity (62.7%) and specificity (96.5%). The serum levels of the markers were significantly higher in patients with colonic cancer than those in patients with rectal cancer (P<0.05). The levels were positively correlated with the size of the growth and stage of the disease. Serum tumor marker levels were also significantly higher in patients with metastasis (regional/distant) than those in patients without metastasis (P<0.05). Conclusion: Determination of serum CEA, CA50 and CA19-9 levels had definite value for the diagnosis and assessment of the pathology as well as biologic behavior colorectal cancer. Combined assay of the three could enhance the diagnostic sensitivity and specificity. (authors)

  12. CLSI-based transference of CALIPER pediatric reference intervals to Beckman Coulter AU biochemical assays.

    Science.gov (United States)

    Abou El Hassan, Mohamed; Stoianov, Alexandra; Araújo, Petra A T; Sadeghieh, Tara; Chan, Man Khun; Chen, Yunqi; Randell, Edward; Nieuwesteeg, Michelle; Adeli, Khosrow

    2015-11-01

    The CALIPER program has established a comprehensive database of pediatric reference intervals using largely the Abbott ARCHITECT biochemical assays. To expand clinical application of CALIPER reference standards, the present study is aimed at transferring CALIPER reference intervals from the Abbott ARCHITECT to Beckman Coulter AU assays. Transference of CALIPER reference intervals was performed based on the CLSI guidelines C28-A3 and EP9-A2. The new reference intervals were directly verified using up to 100 reference samples from the healthy CALIPER cohort. We found a strong correlation between Abbott ARCHITECT and Beckman Coulter AU biochemical assays, allowing the transference of the vast majority (94%; 30 out of 32 assays) of CALIPER reference intervals previously established using Abbott assays. Transferred reference intervals were, in general, similar to previously published CALIPER reference intervals, with some exceptions. Most of the transferred reference intervals were sex-specific and were verified using healthy reference samples from the CALIPER biobank based on CLSI criteria. It is important to note that the comparisons performed between the Abbott and Beckman Coulter assays make no assumptions as to assay accuracy or which system is more correct/accurate. The majority of CALIPER reference intervals were transferrable to Beckman Coulter AU assays, allowing the establishment of a new database of pediatric reference intervals. This further expands the utility of the CALIPER database to clinical laboratories using the AU assays; however, each laboratory should validate these intervals for their analytical platform and local population as recommended by the CLSI. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Non-destructive assay of leached hulls in a nuclear fuel reprocessing plant

    International Nuclear Information System (INIS)

    Hofstetter, K.J.; Henderson, B.C.; Gray, J.H.; Huff, G.A.

    1978-01-01

    The hull monitor at the Barnwell Nuclear Fuels Plant (BNFP) will be a remotely controlled, fully automated system designed to quantitatively assay leached hulls for undissolved U and Pu. The hull monitor will assay the hulls from one metric ton of fuel per dissolver basket with the design goal of detecting 0.1% undissolved fuel and yet remain within the framework of the BNFP materials flow of five hull baskets per day. The non-destructive assay will be accomplished using a computer-based gamma-ray pulse height analysis system employing a 5 x 5 inch NaI(Tl) scintillation detector. The intense radiations from the fission product isotopes and the activation product isotopes produced in the reactor prevent direct assay of the undissolved fuel left in the hulls. The measurement will be made indirectly by demonstrating a correlation between the amount of 144 Ce undissolved and the remaining U. The isotope 144 Ce is a direct fission product with high cumulative yield. The daughter isotope 144 Pr has a gamma ray at 2.18 MeV well above other predominant radiations in the spectrum from the major interferences 60 Co, 58 Co, 95 Zr( 95 Nb), 137 Cs and 106 Ru( 106 Rh). Segmented scanning operation of the hull monitor is accomplished by rotation and vertical transversal of the hulls container past the detector station. Proper collimation and absorbers are required to maximize the 144 Ce( 144 Pr) to background ratio. A basket indexer is provided which monitors the scanning rate and ensures repositioning. The leached hull monitor system will be interfaced to a computer-based multichannel analyzer for ease of operation and data handling. A calibration basket has been fabricated to accomodate radioactive sources and inactive Zircaloy hulls

  14. Direct replacement of antibodies with molecularly imprinted polymer (MIP) nanoparticles in ELISA – development of a novel assay for vancomycin

    Science.gov (United States)

    Chianella, Iva; Guerreiro, Antonio; Moczko, Ewa; Caygill, J. Sarah; Piletska, Elena V.; Perez De Vargas Sansalvador, Isabel M.; Whitcombe, Michael J.; Piletsky, Sergey A.

    2016-01-01

    A simple and straightforward technique for coating microplate wells with molecularly imprinted polymer nanoparticles (nanoMIPs) to develop ELISA type assays is presented here for the first time. NanoMIPs were synthesized by a solid phase approach with immobilized vancomycin (template) and characterized using Biacore 3000, dynamic light scattering and electron microscopy. Immobilization, blocking and washing conditions were optimized in microplate format. The detection of vancomycin was achieved in competitive binding experiments with a HRP-vancomycin conjugate. The assay was capable of measuring vancomycin in buffer and in blood plasma within the range 0.001-70 nM with a detection limit of 0.0025 nM (2.5 pM). The sensitivity of the assay was three orders of magnitude better than a previously described ELISA based on antibodies. In these experiments nanoMIPs have shown high affinity and minimal interference from blood plasma components. Immobilized nanoMIPs were stored for 1 month at room temperature without any detrimental effects to their binding properties. The high affinity of nanoMIPs and the lack of a requirement for cold chain logistics make them an attractive alternative to traditional antibodies used in ELISA. PMID:23947402

  15. First results with a radioreceptor-assay (TRAK-Assay) for TSH-receptor-autoantibodies

    International Nuclear Information System (INIS)

    Becker, W.; Reiners, C.; Boerner, W.

    1983-01-01

    A new radioreceptor-assay (TRAK-assay) for autoantibodies against TSH-receptors was tested in 48 untreated thyrotoxic patients (26 regional autonomies, 22 toxic diffuse goiters). None of the 26 patients with regional autonomy showed positive autoantibody-titers. 4 patients with toxic diffuse goiter and thyrotoxic exophthalmos were TRAK-positive. Positive titers of microsomal and thyreoglobulin autoantibodies could be seen in 8 of 9 patients with positive TRAK-titers. In accordance with the conventional methods for detecting thyroid-stimulating immunoglobulins the new TRAK-assay seems to be suited for differentiating between immunogenic toxic diffuse goiter (Graves' disease) and goiter with disseminated autonomy as well as for prediction of relapse. (orig.) [de

  16. Comprehensive analysis of sperm DNA fragmentation by five different assays: TUNEL assay, SCSA, SCD test and alkaline and neutral Comet assay.

    Science.gov (United States)

    Ribas-Maynou, J; García-Peiró, A; Fernández-Encinas, A; Abad, C; Amengual, M J; Prada, E; Navarro, J; Benet, J

    2013-09-01

    Sperm DNA fragmentation (SDF) is becoming an important test to assess male infertility. Several different tests are available, but no consensus has yet been reached as to which tests are most predictive of infertility. Few publications have reported a comprehensive analysis comparing these methods within the same population. The objective of this study was to analyze the differences between the five most common methodologies, to study their correlations and to establish their cut-off values, sensitivity and specificity in predicting male infertility. We found differences in SDF between fertile donors and infertile patients in TUNEL, SCSA, SCD and alkaline Comet assays, but none with the neutral Comet assay. The alkaline COMET assay was the best in predicting male infertility followed by TUNEL, SCD and SCSA, whereas the neutral COMET assay had no predictive power. For our patient population, threshold values for infertility were 20.05% for TUNEL assay, 18.90% for SCSA, 22.75% for the SCD test, 45.37% for alkaline Comet and 34.37% for neutral Comet. This work establishes in a comprehensive study that the all techniques except neutral Comet are useful to distinguish fertile and infertile men. © 2013 American Society of Andrology and European Academy of Andrology.

  17. New Technology For Fissile Assay In Spent Fuel Using LSDS

    International Nuclear Information System (INIS)

    Lee, Yongdeok; Park, Changje; Park, Geunil; Lee, Jungwon; Song, Keechan

    2012-01-01

    The principle of LSDS is very simple. The interrogated neutron induces energy dependent characteristic fission from fissile materials in spent fuel. The fission threshold detector screens the prompt fast fission neutrons from background and fissionable materials. However, intense source neutron is necessary to overcome radiation background. The detected signals have a direct relationship to the content of each fissile material. The isotopic fissile assay using LSDS is applicable for optimum design of spent fuel storage and management, quality assurance of recycled nuclear material, maximization of burnup credit. Another important application is verity burnup code and provide correction factor for improving the fissile material content, fission product correction factor for improving the fissile material content, fission product content and theoretical burnup. Additionally, the isotopic fissile content assay will increase the transparence and credibility for spent fuel storage and its re-utilization, as internationally demanded

  18. A novel multiplex PCR assay for simultaneous detection of nine clinically significant bacterial pathogens associated with bovine mastitis.

    Science.gov (United States)

    Ashraf, Aqeela; Imran, Muhammad; Yaqub, Tahir; Tayyab, Muhammad; Shehzad, Wasim; Thomson, Peter C

    2017-06-01

    For rapid and simultaneous detection of nine bovine mastitic pathogens, a sensitive and specific multiplex PCR assay was developed. The assay was standardized using reference strains and validated on mastitic milk cultures which were identified to species level based on 16S rRNA sequencing. Multiplex PCR assay also efficiently detected the target bacterial strains directly from milk. The detection limit of the assay was up to 50 pg for DNA isolated from pure cultures and 10 4  CFU/ml for spiked milk samples. As estimated by latent class analysis, the assay was sensitive up to 88% and specific up to 98% for targeted mastitic pathogens, compared with the bacterial culture method and the 16S rRNA sequence analysis. This novel molecular assay could be useful for monitoring and maintaining the bovine udder health, ensuring the bacteriological safety of milk, and conducting epidemiological studies. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Evaluation of a reverse-hybridization StripAssay for the detection of genetic polymorphisms leading to acenocoumarol sensitivity.

    Science.gov (United States)

    Gialeraki, Argyri; Markatos, Christos; Grouzi, Elisabeth; Merkouri, Efrosyni; Travlou, Anthi; Politou, Marianna

    2010-04-01

    Acenocoumarol is mainly catabolized by CYP2C9 isoform of cytochrome P450 (CYP) liver complex and exerts its anticoagulant effect through the inhibition of Vitamin K Epoxide Reductase (VKOR). The most important genetic polymorphisms which lead to an impaired enzymatic activity and therefore predispose to acenocoumarol sensitivity, are considered to be CYP2C9*2 (Arg144Cys), CYP2C9*3 (Ile359Leu) and VKORC1-1639G>A, respectively. In this study we compared the results of the PGXThrombo StripAssay kit (ViennaLab Diagnostics,Vienna, Austria) with direct DNA sequencing and in house Restriction Fragment Length Polymorphisms (RFLP) for the detection of the aforementioned Single Nucleotide Polymorphisms (SNPs). The reverse hybridization StripAssay was found to be equally effective with RFLP and direct DNA sequencing for the detection of CYP2C9*2 and CYP2C9*3 polymorphisms, respectively. The comparison of the RFLP reference method with the reverse hybridization StripAssay for the detection of VKORC1-1639 G>A polymorphism showed that the reverse hybridization StripAsssay might misclassify some A/A homozygotes as heterozygotes. Optimization of the hybridization procedures may eliminate the extra low signal band observed in some samples at the reverse hybridization StripAssay and improve its diagnostic value.

  20. Establishment and application of a modified membrane-blot assay for Rhizomucor miehei lipases aimed at improving their methanol tolerance and thermostability.

    Science.gov (United States)

    He, Dong; Luo, Wen; Wang, Zhiyuan; Lv, Pengmei; Yuan, Zhenhong; Huang, Shaowei; Xv, Jingliang

    2017-07-01

    Directed evolution has been proved an effective way to improve the stability of proteins, but high throughput screening assays for directed evolution with simultaneous improvement of two or more properties are still rare. In this study, we aimed to establish a membrane-blot assay for use in the high-throughput screening of Rhizomucor miehei lipases (RMLs). With the assistance of the membrane-blot screening assay, a mutant E47K named G10 that showed improved thermal stability was detected in the first round of error-prone PCR. Using G10 as the parent, two variants G10-11 and G10-20 that showed improved thermal stability and methanol tolerance without loss of activity compared to the wild type RML were obtained. The T 50 60 -value of G10-11 and G10-20 increased by 12°C and 6.5°C, respectively. After incubation for 1h, the remaining residual activity of G10-11 and G10-20 was 63.45% and 74.33%, respectively, in 50% methanol, and 15.98% and 30.22%, respectively, in 80% methanol. Thus, we successfully developed a membrane-blot assay that could be used for the high-throughput screening of RMLs with improved thermostability and methanol tolerance. Based on our findings, we believe that our newly developed membrane-blot assay will have potential applications in directed evolution in the future. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. High-throughput assay of 9 lysosomal enzymes for newborn screening.

    Science.gov (United States)

    Spacil, Zdenek; Tatipaka, Haribabu; Barcenas, Mariana; Scott, C Ronald; Turecek, Frantisek; Gelb, Michael H

    2013-03-01

    There is interest in newborn screening of lysosomal storage diseases (LSDs) because of the availability of treatments. Pilot studies have used tandem mass spectrometry with flow injection of samples to achieve multiplex detection of enzyme products. We report a multiplexing method of 9 enzymatic assays that uses HPLC-tandem mass spectrometry (MS/MS). The assay of 9 enzymes was carried out in 1 or 2 buffers with a cassette of substrates and internal standards and 1 or 2 punches of a dried blood spot (DBS) from a newborn screening card as the source of enzymes. The pre-HPLC-MS/MS sample preparation required only 4 liquid transfers before injection into a dual-column HPLC equipped with switching valves to direct the flow to separation and column equilibration. Product-specific and internal standard-specific ion fragmentations were used for MS/MS quantification in the selected reaction monitoring mode. Analysis of blood spots from 58 random newborns and lysosomal storage disease-affected patients showed that the assay readily distinguished affected from nonaffected individuals. The time per 9-plex analysis (1.8 min) was sufficiently short to be compatible with the workflow of newborn screening laboratories. HPLC-MS/MS provides a viable alternative to flow-injection MS/MS for the quantification of lysosomal enzyme activities. It is possible to assay 9 lysosomal enzymes using 1 or 2 reaction buffers, thus minimizing the number of separate incubations necessary.

  2. Differences in quantification of DNA double-strand breaks assessed by 53BP1/γH2AX focus formation assays and the comet assay in mammalian cells treated with irradiation and N-acetyl-L-cysteine

    International Nuclear Information System (INIS)

    Kurashige, Tomomi; Shimamura, Mika; Nagayama, Yuji

    2016-01-01

    The biological effect of ionizing radiation (IR) on genomic DNA is thought to be either direct or indirect; the latter is mediated by IR induction of free radicals and reactive oxygen species (ROS). This study was designed to evaluate the effect of N-acetyl-L-cysteine (NAC), a well-known ROS-scavenging antioxidant, on IR induction of genotoxicity, cytotoxicity and ROS production in mammalian cells, and aimed to clarify the conflicting data in previous publications. Although we clearly demonstrate the beneficial effect of NAC on IR-induced genotoxicity and cytotoxicity (determined using the micronucleus assay and cell viability/clonogenic assays), the data on NAC's effect on DNA double-strand break (DSB) formation were inconsistent in different assays. Specifically, mitigation of IR-induced DSBs by NAC was readily detected by the neutral comet assay, but not by the γH2AX or 53BP1 focus assays. NAC is a glutathione precursor and exerts its effect after conversion to glutathione, and presumably it has its own biological activity. Assuming that the focus assay reflects the biological responses to DSBs (detection and repair), while the comet assay reflects the physical status of genomic DNA, our results indicate that the comet assay could readily detect the antioxidant effect of NAC on DSB formation. However, NAC's biological effect might affect the detection of DSB repair by the focus assays. Our data illustrate that multiple parameters should be carefully used to analyze DNA damage when studying potential candidates for radioprotective compounds

  3. Rapid Detection of Staphylococcus aureus and Methicillin-Resistant S. aureus in Atopic Dermatitis by Using the BD Max StaphSR Assay.

    Science.gov (United States)

    Lee, Mi Kyung; Park, Kui Young; Jin, Taewon; Kim, Ju Hee; Seo, Seong Jun

    2017-07-01

    Eczematous lesions of atopic dermatitis (AD) patients are known to be a source of Staphylococcus aureus (SA) transmission and might be a reservoir for community-associated methicillin-resistant SA (MRSA). The BD Max StaphSR (BD-SR) is a fully automated, multiplex real-time PCR assay for the direct detection and differentiation of SA and MRSA from nasal swab samples. We evaluated the detection rates of SA and MRSA from skin lesions of outpatients with AD using the BD-SR assay, and determined the usefulness of the BD-SR assay. A total of 244 skin swab samples (skin lesions of 213 outpatients with AD and normal skin of 31 healthy controls) were tested directly by using the BD-SR assay. Of the 213 samples from patients with AD, 69 (32.4%) were positive for SA, 6 (8.7%) of which were positive for MRSA. Only 1 (3.2%) of 31 samples from healthy controls was positive for SA. The BD-SR assay is effective for the rapid detection of SA and MRSA from skin swab samples, which can provide important information for managing patients with AD and preventing the spread of MRSA. © The Korean Society for Laboratory Medicine.

  4. rK39 enzyme-linked immunosorbent assay for diagnosis of Leishmania donovani infection

    NARCIS (Netherlands)

    Zijlstra, E. E.; Daifalla, N. S.; Kager, P. A.; Khalil, E. A.; El-Hassan, A. M.; Reed, S. G.; Ghalib, H. W.

    1998-01-01

    The rK39 enzyme-linked immunosorbent assay (ELISA) was compared with the direct agglutination test (DAT) for Leishmania donovani infection in the Sudan. rK39 ELISA proved more sensitive than DAT in diagnosis of kala-azar (93 and 80%, respectively); both tests may remain positive up to 24 months

  5. Combining Cytotoxicity Assessment and Xenopus laevis Phenotypic Abnormality Assay as a Predictor of Nanomaterial Safety.

    Science.gov (United States)

    Al-Yousuf, Karamallah; Webster, Carl A; Wheeler, Grant N; Bombelli, Francesca Baldelli; Sherwood, Victoria

    2017-08-04

    The African clawed frog, Xenopus laevis, has been used as an efficient pre-clinical screening tool to predict drug safety during the early stages of the drug discovery process. X. laevis is a relatively inexpensive model that can be used in whole organism high-throughput assays whilst maintaining a high degree of homology to the higher vertebrate models often used in scientific research. Despite an ever-increasing volume of biomedical nanoparticles (NPs) in development, their unique physico-chemical properties challenge the use of standard toxicology assays. Here, we present a protocol that directly compares the sensitivity of X. laevis development as a tool to assess potential NP toxicity by observation of embryo phenotypic abnormalities/lethality after NP exposure, to in vitro cytotoxicity obtained using mammalian cell lines. In combination with conventional cytotoxicity assays, the X. laevis phenotypic assay provides accurate data to efficiently assess the safety of novel biomedical NPs. © 2017 by John Wiley & Sons, Inc. Copyright © 2017 by John Wiley & Sons, Inc.

  6. Validation of an in vitro contractility assay using canine ventricular myocytes

    Energy Technology Data Exchange (ETDEWEB)

    Harmer, A.R., E-mail: alex.harmer@astrazeneca.com; Abi-Gerges, N.; Morton, M.J.; Pullen, G.F.; Valentin, J.P.; Pollard, C.E.

    2012-04-15

    Measurement of cardiac contractility is a logical part of pre-clinical safety assessment in a drug discovery project, particularly if a risk has been identified or is suspected based on the primary- or non-target pharmacology. However, there are limited validated assays available that can be used to screen several compounds in order to identify and eliminate inotropic liability from a chemical series. We have therefore sought to develop an in vitro model with sufficient throughput for this purpose. Dog ventricular myocytes were isolated using a collagenase perfusion technique and placed in a perfused recording chamber on the stage of a microscope at ∼ 36 °C. Myocytes were stimulated to contract at a pacing frequency of 1 Hz and a digital, cell geometry measurement system (IonOptix™) was used to measure sarcomere shortening in single myocytes. After perfusion with vehicle (0.1% DMSO), concentration–effect curves were constructed for each compound in 4–30 myocytes taken from 1 or 2 dog hearts. The validation test-set was 22 negative and 8 positive inotropes, and 21 inactive compounds, as defined by their effect in dog, cynolomolgous monkey or humans. By comparing the outcome of the assay to the known in vivo contractility effects, the assay sensitivity was 81%, specificity was 75%, and accuracy was 78%. With a throughput of 6–8 compounds/week from 1 cell isolation, this assay may be of value to drug discovery projects to screen for direct contractility effects and, if a hazard is identified, help identify inactive compounds. -- Highlights: ► Cardiac contractility is an important physiological function of the heart. ► Assessment of contractility is a logical part of pre-clinical drug safety testing. ► There are limited validated assays that predict effects of compounds on contractility. ► Using dog myocytes, we have developed an in vitro cardiac contractility assay. ► The assay predicted the in vivo contractility with a good level of accuracy.

  7. Direct solid phase radioimmunoassay for chicken lipoprotein lipase

    International Nuclear Information System (INIS)

    Cheung, A.H.; Bensadoun, A.; Cheng, C.

    1979-01-01

    A direct, noncompetitive immunoassay for chicken lipoprotein lipase (LPL) was developed. Antibodies to LPL were purified by immunoadsorption chromatography of goat antisera on an LPL-Sepharose column. Purified anti-LPL immunoglobulins were coupled covalently to hydrophilic polyacrylamide beads by a carbodiimide reagent. An excess amount of these beads was incubated with the sample on the standard to be assayed. The amount of LPL immobilized by the heads was then detected by an excess amount of 125 I-labeled anti-LPL immunoglobulin. A linear relationship was obtained between the radioactivity bound and the amount of highly purified LPL used as a standard. The range of the assay was from 0.1 to 1.1 ng PLP. The assay was specific for chicken LPL and showed no cross-reactivity with liver lipase. It does not distinguish heat-inactivated from catalytically active enzyme species. This assay should be useful in studies of lipoprotein lipase where both catalytic activity and enzyme mass need to be quantitated

  8. Safeguards and Non-destructive Assay

    International Nuclear Information System (INIS)

    Carchon, R.; Bruggeman, M.

    2001-01-01

    SCK-CEN's programme on safeguards and non-destructive assay includes: (1) various activities to assure nuclear materials accountancy; (2) contributes to the implementation of Integrated Safeguards measures in Belgium and to assist the IAEA through the Belgian Support Programme; (3) renders services to internal and external customers in the field of safeguards; (4) improves passive neutron coincidence counting techniques for waste assay and safeguards verification measurements by R and D on correlation algorithms implemented via software or dedicated hardware; (5) improves gamma assay techniques for waste assay by implementing advanced scanning techniques and different correlation algorithms; and (6) develops numerical calibration techniques. Major achievements in these areas in 2000 are reported

  9. Open innovation for phenotypic drug discovery: The PD2 assay panel.

    Science.gov (United States)

    Lee, Jonathan A; Chu, Shaoyou; Willard, Francis S; Cox, Karen L; Sells Galvin, Rachelle J; Peery, Robert B; Oliver, Sarah E; Oler, Jennifer; Meredith, Tamika D; Heidler, Steven A; Gough, Wendy H; Husain, Saba; Palkowitz, Alan D; Moxham, Christopher M

    2011-07-01

    Phenotypic lead generation strategies seek to identify compounds that modulate complex, physiologically relevant systems, an approach that is complementary to traditional, target-directed strategies. Unlike gene-specific assays, phenotypic assays interrogate multiple molecular targets and signaling pathways in a target "agnostic" fashion, which may reveal novel functions for well-studied proteins and discover new pathways of therapeutic value. Significantly, existing compound libraries may not have sufficient chemical diversity to fully leverage a phenotypic strategy. To address this issue, Eli Lilly and Company launched the Phenotypic Drug Discovery Initiative (PD(2)), a model of open innovation whereby external research groups can submit compounds for testing in a panel of Lilly phenotypic assays. This communication describes the statistical validation, operations, and initial screening results from the first PD(2) assay panel. Analysis of PD(2) submissions indicates that chemical diversity from open source collaborations complements internal sources. Screening results for the first 4691 compounds submitted to PD(2) have confirmed hit rates from 1.6% to 10%, with the majority of active compounds exhibiting acceptable potency and selectivity. Phenotypic lead generation strategies, in conjunction with novel chemical diversity obtained via open-source initiatives such as PD(2), may provide a means to identify compounds that modulate biology by novel mechanisms and expand the innovation potential of drug discovery.

  10. A novel, colorimetric neutralization assay for measuring antibodies to influenza viruses.

    Science.gov (United States)

    Lehtoranta, Liisa; Villberg, Anja; Santanen, Riitta; Ziegler, Thedi

    2009-08-01

    A colorimetric cell proliferation assay for measuring neutralizing antibodies to influenza viruses in human sera is described. Following a 90-min incubation, the serum-virus mixture was transferred to Madin-Darby canine kidney cells cultured in 96-well plates. After further incubation for three days, a tetrazolium salt was added to the wells. Cellular mitochondrial dehydrogenases cleave the tetrazolium salt to formazan, and the resulting color change is read by a spectrophotometer. The absorbance values correlate directly to the number of viable cells in the assay well and thus also to the neutralizing activity of influenza-specific antibodies present in the serum. With the few hands-on manipulations required, this assay allows simultaneous testing of a considerable number of sera, offers opportunities for automation, and is suitable for use under biosafety level-3 conditions. The test was used to study the antibody response after the administration of seasonal, inactivated, trivalent influenza vaccine. Antibody titers determined by the neutralization test in pre- and post-vaccination serum pairs were compared with those obtained by the hemagglutination inhibition assay. The neutralization test yielded higher pre- and post-vaccination titers and a larger number of significant increases in post-vaccination antibody titer than the hemagglutination inhibition test. This new test format could serve as a valuable laboratory tool for influenza vaccine studies.

  11. Improved radioenzymatic assay for plasma norepinephrine using purified phenylethanolamine n-methyltransferase

    International Nuclear Information System (INIS)

    Bowsher, R.R.; Henry, D.P.

    1986-01-01

    Radioenzymatic assays have been developed for catecholamines using either catechol O-methyltransferase (COMT) or phenylethanolamine N-methyltransferase (PNMT). Assays using PNMT are specific for norepinephrine (NE) and require minimal manipulative effort but until now have been less sensitive than the more complex procedures using COMT. The authors report an improved purification scheme for bovine PNMT which has permitted development of an NE assay with dramatically improved sensitivity (0.5 pg), specificity and reproducibility (C.V. < 5%). PNMT was purified by sequential pH 5.0 treatment and dialysis and by column chromatographic procedures using DEAE-Sephacel, Sepharcryl S-200 and Phenyl-Boronate Agarose. Recovery of PNMT through the purification scheme was 50%, while blank recovery was <.001%. NE can be directly quantified in 25 ul of human plasma and an 80 tube assay can be completed within 4 h. The capillary to venous plasma NE gradient was examined in 8 normotensive male subjects. Capillary plasma (NE (211.2 +/- 61.3 pg/ml)) was lower than venous plasma NE (366.6 +/- 92.5 pg/ml) in all subjects (p < 0.005). This difference suggests that capillary (NE) may be a unique indicator of sympathetic nervous system activity in vivo. In conclusion, purification of PNMT has facilitated development of an improved radioenzymatic for NE with significantly improved sensitivity

  12. Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory.

    Science.gov (United States)

    Dhungana, Neha; Morris, Cory; Krasowski, Matthew D

    2017-08-01

    The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. Retrospective study was done over an approximately 3.5 year period. The main automated chemistry instrumentation was a Roche Diagnostics cobas 8000 line. The Roche Direct Bilirubin assay was compared to Diazyme Laboratories Direct Bilirubin Assay and Randox Laboratories Direct Bilirubin assay using manufacturer's guidelines for hemolysis index, lipemia index, and analytical measurement range (AMR). Retrospective data was analyzed for 47,333 serum/plasma specimens that had clinical orders for direct bilirubin. A total of 5943 specimens (12.6%) exceeded the hemolysis index limit for the Roche method compared to only 0.2% and 0.05% of specimens for the Diazyme and Randox methods, respectively. The impact was particularly large on patients less than 2 years old, for which 51.3% of specimens exceeded the hemolysis index for the Roche method. A total of 1671 specimens (3.5%) exceeded the lipemia index limit for the Roche method compared to less than 0.1% for the Randox method. Lastly, 988 (2.1%) of specimens had direct bilirubin concentrations exceeding the upper AMR limit of 10 mg/dL [171 µmol/L] for the Roche assay compared to less than 1% of specimens for the vanadate oxidase methods. Vanadate oxidase direct bilirubin methods offer advantages over diazo methods in terms of less interference by hemolysis and lipemia, as well as wider AMR. The advantages are particularly evident for neonatal and infant populations.

  13. Revolutionary introduction of RIA/IRMA methodology in medical diagnostics: a study employing the technique for hyperprolactinemia and its correlation with hypothyroidism

    International Nuclear Information System (INIS)

    Tasneem, A.

    2011-01-01

    The aim of the study was to determine the incidence of hyperprolactinemia, its underlying causes and consequences, and to study its correlation with hypothyroidism. The study was carried out on 1365 male and female subjects referred to Centre for Nuclear Medicine Lahore for hormonal estimation. Serum Prolactin and thyroid stimulating hormone (TSH) levels were measured using IRMA kits. Prevalence of hyperprolactinemia turned out to be 4.90%. Menstrual irregularity appeared as a major consequence. The incidence rate was the highest in the age range of 21-27 years. Hypothyroidism in hyperprolactinemic subjects was observed to be 22.7%. i) Immunoradiometric assay is a micro analytical technique which can measure very minute amount of the antigens in the serum. II) Prevalence of hypothyroidism in hyperprolactinemic subjects in our population is promising enough to estimate thyroid hormone levels in hyperprolactinemic patients. (author)

  14. Posttranslational heterogeneity of bone alkaline phosphatase in metabolic bone disease.

    Science.gov (United States)

    Langlois, M R; Delanghe, J R; Kaufman, J M; De Buyzere, M L; Van Hoecke, M J; Leroux-Roels, G G

    1994-09-01

    Bone alkaline phosphatase is a marker of osteoblast activity. In order to study the posttranscriptional modification (glycosylation) of bone alkaline phosphatase in bone disease, we investigated the relationship between mass and catalytic activity of bone alkaline phosphatase in patients with osteoporosis and hyperthyroidism. Serum bone alkaline phosphatase activity was measured after lectin precipitation using the Iso-ALP test kit. Mass concentration of bone alkaline phosphatase was determined with an immunoradiometric assay (Tandem-R Ostase). In general, serum bone alkaline phosphatase mass and activity concentration correlated well. The activity : mass ratio of bone alkaline phosphatase was low in hyperthyroidism. Activation energy of the reaction catalysed by bone alkaline phosphatase was high in osteoporosis and in hyperthyroidism. Experiments with neuraminidase digestion further demonstrated that the thermodynamic heterogeneity of bone alkaline phosphatase can be explained by a different glycosylation of the enzyme.

  15. High content screening for G protein-coupled receptors using cell-based protein translocation assays

    DEFF Research Database (Denmark)

    Grånäs, Charlotta; Lundholt, Betina Kerstin; Heydorn, Arne

    2005-01-01

    G protein-coupled receptors (GPCRs) have been one of the most productive classes of drug targets for several decades, and new technologies for GPCR-based discovery promise to keep this field active for years to come. While molecular screens for GPCR receptor agonist- and antagonist-based drugs...... will continue to be valuable discovery tools, the most exciting developments in the field involve cell-based assays for GPCR function. Some cell-based discovery strategies, such as the use of beta-arrestin as a surrogate marker for GPCR function, have already been reduced to practice, and have been used...... as valuable discovery tools for several years. The application of high content cell-based screening to GPCR discovery has opened up additional possibilities, such as direct tracking of GPCRs, G proteins and other signaling pathway components using intracellular translocation assays. These assays provide...

  16. Electrochemical Branched-DNA Assay for Polymerase Chain Reaction-Free Detection and Quantification of Oncogenes in Messenger RNA

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ai Cheng; Dai, Ziyu; Chen, Baowei; Wu, Hong; Wang, Jun; Zhang, Aiguo; Zhang, Lurong; Lim, Tit-Meng; Lin, Yuehe

    2008-12-01

    We describe a novel electrochemical branched-DNA (bDNA) assay for polymerase chain reaction (PCR)-free detection and quantification of p185 BCR-ABL leukemia fusion transcript in the population of messenger RNA (mRNA) extracted from cell lines. The bDNA amplifier carrying high loading of alkaline phosphatase (ALP) tracers was used to amplify targets signal. The targets were captured on microplate well surfaces through cooperative sandwich hybridization prior to the labeling of bDNA. The activity of captured ALP was monitored by square-wave voltammetric (SWV) analysis of the electroactive enzymatic product in the presence of 1-napthyl-phosphate. The specificity and sensitivity of assay enabled direct detection of target transcript in as little as 4.6 ng mRNA without PCR amplification. In combination with the use of a well-quantified standard, the electrochemical bDNA assay was capable of direct use for a PCR-free quantitative analysis of target transcript in total mRNA population. The approach thus provides a simple, sensitive, accurate and quantitative tool alternate to the RQ-PCR for early disease diagnosis.

  17. A comparison of assays measuring the viability of Legionella ...

    Science.gov (United States)

    Background: The relatively high prevalence of Legionella pneumophila in premise plumbing systems has been widely reported. Published reports indicate Legionella has a comparatively high resistance to chlorine and moreover has the ability to grow in phagocytic amoeba which could provide additional protection in chlorinated drinking water distribution systems. Copper-Silver (Cu-Ag) ionization treatment systems are commercially available for use in large building water systems to help control the risks from Legionella bacteria. The objectives of this study were to develop and optimize Legionella viability assays and use them to investigate the viability of Legionella bacteria after exposure to water treated with coppper and silver ions. Methods: Log phase L. pneumophila cells were used in all experiments and were generated by incubation at 35C for 48 hours in buffered yeast extract broth. Viability assays used included plating on buffered charcoal yeast extract agar to determine the number of culturable cells and treating cells with propidium monoazide (PMA) or ethidium monoazide (EMA) followed by quantitative PCR targeting mip gene of L. pneumophila. The qPCR viability assays were optimized using L. pneumophila inactivated by heat treatment at 65C for 60 min. The effectiveness of Cu-Ag ionization treatment was studied by inoculating L. pneumonia at 105 CFU/mL in water collected directly from a building water system that employed this technology and incubat

  18. Comparison of antibody responses to human papillomavirus vaccination as measured by three assays

    Directory of Open Access Journals (Sweden)

    Hilary Ann Robbins

    2014-01-01

    Full Text Available Background: Different assays, including the competitive Luminex immunoassay (cLIA, secreted alkaline phosphatase neutralization assay (SEAP-NA, and virus-like particle-based ELISA, are commonly used to measure antibody responses after human papillomavirus (HPV vaccination. Direct assay comparisons aid interpretation of immunogenicity data evaluated by different assays. Methods: We compared cLIA to SEAP-NA and ELISA among 51 HPV16/18-vaccinated women enrolled in the Costa Rica Vaccine Trial. We tested replicate serum samples collected at months 0, 1, and 12 by HPV16/18 cLIA, SEAP-NA, and ELISA. For a subset (N=10, we further tested month 24 and 36 samples. We calculated seroprevalence estimates and Spearman rank correlation coefficients comparing cLIA to SEAP-NA and ELISA.Results: After one vaccine dose, seroprevalence by SEAP-NA and ELISA was 100% (both HPV16 and HPV18, and by cLIA was 96% (95% CI 87%-100% for HPV16 and 71% (95% CI 56%-83% for HPV18. Seroprevalence was 100% by all assays after 3 doses. Correlation between assays was high after one vaccine dose (cLIA/SEAP-NA ρ=0.91 (HPV16 and ρ=0.86 (HPV18; cLIA/ELISA ρ=0.84 (HPV16 and ρ=0.74 (HPV18; all p<0.001 and remained high through month 36. Ratios of mean antibody levels to seropositivity cutoffs at month 36 were lower for cLIA than for SEAP-NA or ELISA, particularly for HPV18 (HPV18 ratio for cLIA 1.9, SEAP-NA 3.5, ELISA 3.4.Conclusion: Though correlation between cLIA and SEAP-NA/ELISA is high and stable after vaccination, the assays differ in scale and sensitivity, with notable differences after 1 vaccine dose and for HPV18. Our results demonstrate that comparisons of antibody responses to HPV vaccination measured by different assays are approximate, and must consider biological and technical differences between assays.

  19. Adrenal status assessed by direct radioimmunoassay of cortisol in whole saliva or parotid saliva

    International Nuclear Information System (INIS)

    Walker, R.F.; Riad-Fahmy, D.; Read, G.F.

    1978-01-01

    We describe a direct radioimmunoassay for cortisol in 10-μl volumes of parotid saliva or whole saliva. Binding proteins are absent from these fluids, as demonstrated by the excellent correlation between results for samples assayed directly and by a comparison procedure involving extraction with 1,2-dichloroethane. The direct assay is specific, precise, and had a lower limit of sensitivity of 4 pg per assay tube. Comparison of cortisol concentrations in plasma, parotid saliva, and whole saliva in persons undergoing investigations for assessing adrenal function, including stimulation with cosyntropin (Synachthen) and suppression with dexamethasone, indicated that changes in plasma cortisol concentration were accurately and immediately reflected in saliva from either the parotid-gland or whole saliva. A marked circadian rhythm has also been demonstrated for cortisol in parotid-gland saliva and whole saliva. We had to modify the 1,2-dichloroethane extraction procedure for accurate determination of cortisol in parotid saliva and whole saliva of patients undergoing treatment with metyrapone

  20. A sensitive radioimmunosorbent assay for the detection of plant viruses

    International Nuclear Information System (INIS)

    Ghabrial, S.A.; Shepherd, R.J.

    1980-01-01

    A simple and highly sensitive radioimmunosorbent assay (RISA) for the detection of plant viruses is described. The RISA procedure is a microplate method based on the principle of 'double-antibody sandwich' and follows essentially the protocol of the enzyme-linked immunosorbent assay (ELISA) (Clark and Adams, 1977), with the exception that 125 I-labelled γ-globulin is substituted for the γ-globulin enzyme conjugate; the bound 125 I-γ-globulin is dissociated by acidification from the double-antibody sandwich. The radioactivity is proportional to virus concentration, and cauliflower mosaic virus (CaMV) and lettuce mosaic virus (LMV) could be detected at concentrations as low as 5 and 2 ng/ml, respectively. Direct evidence of the adverse effects of conjugation with enzyme on the binding abilities of antibodies is presented. The RISA procedure should prove valuable with viruses for which the ELISA values are too low to be dependable. (author)

  1. Radioactive waste package assay facility. Volume 1. Application of assay technology

    International Nuclear Information System (INIS)

    Findlay, D.J.S.; Green, T.H.; Molesworth, T.V.; Staniforth, D.; Strachan, N.R.; Rogers, J.D.; Wise, M.O.; Forrest, K.R.

    1992-01-01

    This report, in three volumes, covers the work carried out by Taylor Woodrow Construction Ltd., and two major sub-contractors: Harwell Laboratory (AEA Technology) and Siemens Plessey Controls Ltd., on the development of a radioactive waste package assay facility, for cemented 500 litre intermediate level waste drums. In volume 1, the reasons for assay are considered together with the various techniques that can be used, and the information that can be obtained. The practical problems associated with the use of the various techniques in an integrated assay facility are identified, and the key parameters defined. Engineering and operational features are examined and provisional designs proposed for facilities at three throughput levels: 15,000, 750 and 30 drums per year respectively. The capital and operating costs for such facilities have been estimated. A number of recommendations are made for further work. 16 refs., 14 figs., 13 tabs

  2. Evaluation of Elecsys Syphilis Assay for Routine and Blood Screening and Detection of Early Infection.

    Science.gov (United States)

    Kremastinou, J; Polymerou, V; Lavranos, D; Aranda Arrufat, A; Harwood, J; Martínez Lorenzo, M J; Ng, K P; Queiros, L; Vereb, I; Cusini, M

    2016-09-01

    Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results. Copyright © 2016 Kremastinou et al.

  3. Evaluation of Elecsys Syphilis Assay for Routine and Blood Screening and Detection of Early Infection

    Science.gov (United States)

    Kremastinou, J.; Polymerou, V.; Lavranos, D.; Aranda Arrufat, A.; Harwood, J.; Martínez Lorenzo, M. J.; Ng, K. P.; Queiros, L.; Vereb, I.

    2016-01-01

    Treponema pallidum infections can have severe complications if not diagnosed and treated at an early stage. Screening and diagnosis of syphilis require assays with high specificity and sensitivity. The Elecsys Syphilis assay is an automated treponemal immunoassay for the detection of antibodies against T. pallidum. The performance of this assay was investigated previously in a multicenter study. The current study expands on that evaluation in a variety of diagnostic settings and patient populations, at seven independent laboratories. The samples included routine diagnostic samples, blood donation samples, samples from patients with confirmed HIV infections, samples from living organ or bone marrow donors, and banked samples, including samples previously confirmed as syphilis positive. This study also investigated the seroconversion sensitivity of the assay. With a total of 1,965 syphilis-negative routine diagnostic samples and 5,792 syphilis-negative samples collected from blood donations, the Elecsys Syphilis assay had specificity values of 99.85% and 99.86%, respectively. With 333 samples previously identified as syphilis positive, the sensitivity was 100% regardless of disease stage. The assay also showed 100% sensitivity and specificity with samples from 69 patients coinfected with HIV. The Elecsys Syphilis assay detected infection in the same bleed or earlier, compared with comparator assays, in a set of sequential samples from a patient with primary syphilis. In archived serial blood samples collected from 14 patients with direct diagnoses of primary syphilis, the Elecsys Syphilis assay detected T. pallidum antibodies for 3 patients for whom antibodies were not detected with the Architect Syphilis TP assay, indicating a trend for earlier detection of infection, which may have the potential to shorten the time between infection and reactive screening test results. PMID:27358468

  4. Broad-range (pan) Salmonella and Salmonella serotype typhi-specific real-time PCR assays: potential tools for the clinical microbiologist.

    Science.gov (United States)

    Farrell, John J; Doyle, Laura J; Addison, Rachel M; Reller, L Barth; Hall, Geraldine S; Procop, Gary W

    2005-03-01

    We describe broad-range salmonellae (ie, Salmonella) and Salmonella serotype Typhi-specific LightCycler (Roche Diagnostics, Indianapolis, IN) real-time polymerase chain reaction assays. We validated these with a battery of 280 bacteria, 108 of which were salmonellae representing 20 serotypes. In addition, 298 isolates from 170 clinical specimens that were suspected to possibly represent Salmonella were tested with the pan- Salmonella assay. Finally, the pan-Salmonella assay also was used to test DNA extracts from 101 archived, frozen stool specimens, 55 of which were culture-positive for salmonellae. Both assays were 100% sensitive and specific when cultured isolates of the battery were tested. The pan- Salmonella assay also characterized correctly all salmonellae on the primary isolation agar and was 96% sensitive (53/55) and 96% specific (49/51) when nucleic acid extracts from direct stool specimens were tested. These assays represent potential tools the clinical microbiologist could use to screen suspect isolates or stool specimens for Salmonella.

  5. Automation of the dicentric chromosome assay and related assays

    International Nuclear Information System (INIS)

    Balajee, Adayabalam S.; Dainiak, Nicholas

    2016-01-01

    Dicentric Chromosome Assay (DCA) is considered to be the 'gold standard' for personalized dose assessment in humans after accidental or incidental radiation exposure. Although this technique is superior to other cytogenetic assays in terms of specificity and sensitivity, its potential application to radiation mass casualty scenarios is highly restricted because DCA is time consuming and labor intensive when performed manually. Therefore, it is imperative to develop high throughput automation techniques to make DCA suitable for radiological triage scenarios. At the Cytogenetic Biodosimetry Laboratory in Oak Ridge, efforts are underway to develop high throughput automation of DCA. Current status on development of various automated cytogenetic techniques in meeting the biodosimetry needs of radiological/nuclear incident(s) will be discussed

  6. Direct qPCR quantification using the Quantifiler(®) Trio DNA quantification kit.

    Science.gov (United States)

    Liu, Jason Yingjie

    2014-11-01

    The effectiveness of a direct quantification assay is essential to the adoption of the combined direct quantification/direct STR workflow. In this paper, the feasibility of using the Quantifiler(®) Trio DNA quantification kit for the direct quantification of forensic casework samples was investigated. Both low-level touch DNA samples and blood samples were collected on PE swabs and quantified directly. The increased sensitivity of the Quantifiler(®) Trio kit enabled the detection of less than 10pg of DNA in unprocessed touch samples and also minimizes the stochastic effect experienced by different targets in the same sample. The DNA quantity information obtained from a direct quantification assay using the Quantifiler(®) Trio kit can also be used to accurately estimate the optimal input DNA quantity for a direct STR amplification reaction. The correlation between the direct quantification results (Quantifiler(®) Trio kit) and the direct STR results (GlobalFiler™ PCR amplification kit(*)) for low-level touch DNA samples indicates that direct quantification using the Quantifiler(®) Trio DNA quantification kit is more reliable than the Quantifiler(®) Duo DNA quantification kit for predicting the STR results of unprocessed touch DNA samples containing less than 10pg of DNA. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. Evaluation of the Cepheid Xpert MTB/RIF assay for direct detection of Mycobacterium tuberculosis complex in respiratory specimens.

    Science.gov (United States)

    Marlowe, Elizabeth M; Novak-Weekley, Susan M; Cumpio, Joven; Sharp, Susan E; Momeny, Michelle A; Babst, Anna; Carlson, Jonathan S; Kawamura, Masae; Pandori, Mark

    2011-04-01

    A total of 217 specimens submitted for routine smear and culture from three different sites within the western United States were used to evaluate the GeneXpert MTB/RIF assay (for research use only) (Cepheid, Sunnyvale, CA). Overall agreement compared to culture was 89% (98% for smear positives and 72% for smear negatives) for detection of Mycobacterium tuberculosis.

  8. Evaluation of efficiency of nested multiplex allele-specific PCR assay for detection of multidrug resistant tuberculosis directly from sputum samples.

    Science.gov (United States)

    Mistri, S K; Sultana, M; Kamal, S M M; Alam, M M; Irin, F; Nessa, J; Ahsan, C R; Yasmin, M

    2016-05-01

    For an effective control of tuberculosis, rapid detection of multidrug resistant tuberculosis (MDR-TB) is necessary. Therefore, we developed a modified nested multiplex allele-specific polymerase chain reaction (MAS-PCR) method that enables rapid MDR-TB detection directly from sputum samples. The efficacy of this method was evaluated using 79 sputum samples collected from suspected tuberculosis patients. The performance of nested MAS-PCR method was compared with other MDR-TB detection methods like drug susceptibility testing (DST) and DNA sequencing. As rifampicin (RIF) resistance conforms to MDR-TB in greater than 90% cases, only the presence of RIF-associated mutations in rpoB gene was determined by DNA sequencing and nested MAS-PCR to detect MDR-TB. The concordance between nested MAS-PCR and DNA sequencing results was found to be 96·3%. When compared with DST, the sensitivity and specificity of nested MAS-PCR for RIF-resistance detection were determined to be 92·9 and 100% respectively. For developing- and high-TB burden countries, molecular-based tests have been recommended by the World Health Organization for rapid detection of MDR-TB. The results of this study indicate that, nested MAS-PCR assay might be a practical and relatively cost effective molecular method for rapid detection of MDR-TB from suspected sputum samples in developing countries with resource poor settings. © 2016 The Society for Applied Microbiology.

  9. Radiometric assays for glycerol, glucose, and glycogen

    International Nuclear Information System (INIS)

    Bradley, D.C.; Kaslow, H.R.

    1989-01-01

    We have developed radiometric assays for small quantities of glycerol, glucose and glycogen, based on a technique described by Thorner and Paulus for the measurement of glycerokinase activity. In the glycerol assay, glycerol is phosphorylated with [32P]ATP and glycerokinase, residual [32P]ATP is hydrolyzed by heating in acid, and free [32P]phosphate is removed by precipitation with ammonium molybdate and triethylamine. Standard dose-response curves were linear from 50 to 3000 pmol glycerol with less than 3% SD in triplicate measurements. Of the substances tested for interference, only dihydroxyacetone gave a slight false positive signal at high concentration. When used to measure glycerol concentrations in serum and in media from incubated adipose tissue, the radiometric glycerol assay correlated well with a commonly used spectrophotometric assay. The radiometric glucose assay is similar to the glycerol assay, except that glucokinase is used instead of glycerokinase. Dose response was linear from 5 to 3000 pmol glucose with less than 3% SD in triplicate measurements. Glucosamine and N-acetylglucosamine gave false positive signals when equimolar to glucose. When glucose concentrations in serum were measured, the radiometric glucose assay agreed well with hexokinase/glucose-6-phosphate dehydrogenase (H/GDH)-based and glucose oxidase/H2O2-based glucose assays. The radiometric method for glycogen measurement incorporates previously described isolation and digestion techniques, followed by the radiometric assay of free glucose. When used to measure glycogen in mouse epididymal fat pads, the radiometric glycogen assay correlated well with the H/GDH-based glycogen assay. All three radiometric assays offer several practical advantages over spectral assays

  10. Harmonization of radiobiological assays: why and how?

    International Nuclear Information System (INIS)

    Prasanna, Pataje G.

    2014-01-01

    The International Atomic Energy Agency has made available a technical manual for cytogenetic biodosimetry assays (dicentric chromosome aberration (DCA) and cytokinesis-block micronucleus (CBMN) assays) used for radiation dose assessment in radiation accidents. The International Standardization Organization, which develops standards and guidelines, also provides an avenue for laboratory accreditation, has developed guidelines and recommendations for performing cytogenetic biodosimetry assays. Harmonization of DCA and CBMN assays, has improved their accuracy. Double-blinded inter-laboratory comparison studies involving several networks have further validated DCA and CBMN assays and improved the confidence in their potential use for radiation dose assessment in mass casualties. This kind of international harmonization is lacking for pre-clinical radiobiology assays. The widely used pre-clinical assays that are relatively important to set stage for clinical trials include clonogenic assays, flow-cytometry assays, apoptotic assays, and tumor regression and growth delay assays. However, significant inter-laboratory variations occur with respect to data among laboratories. This raises concerns on the reliability and reproducibility of preclinical data that drives further development and translation. Lack of reproducibility may stem from a variety of factors such as poor scientist training, less than optimal experimental design, inadequate description of methodology, and impulse to publish only the positive data etc. Availability of technical manuals, standard operating procedures, accreditation avenues for laboratories performing such assays, inter-laboratory comparisons, and use of standardized protocols are necessary to enhance reliability and reproducibility. Thus, it is important that radiobiological assays are harmonized for laboratory protocols to ensure successful translation of pre-clinical research on radiation effect modulators to help design clinic trials with

  11. Bacterial reduction in genotoxicity of Direct Red 28 dye.

    Science.gov (United States)

    Bafana, Amit; Jain, Minakshi; Agrawal, Gaurav; Chakrabarti, Tapan

    2009-03-01

    Direct Red 28 (DR28) is a benzidine-based azo dye widely used in several countries. It has also been a subject of intense research for its anti-prion activity. Like other benzidine-based azo dyes, it is also carcinogenic and toxic. However, there are very few studies addressing its detoxification. In the present study, a Bacillus velezensis strain was used for detoxification of DR28. Toxicity was checked by a battery of highly sensitive genotoxicity assays like comet assay, DNA ladder formation, terminal deoxynucleotidyl transferase-mediated dUTP nick-end labeling assay and flow cytometric Annexin V binding assay. HL-60 cell line was used as the test system. All the assays showed an initial increase in toxicity upon biodegradation due to release of mutagenic products, like benzidine and 4-aminobiphenyl, from the dye. These intermediates caused significant DNA damage and induced apoptosis in HL-60 cells. Then the culture degraded these mutagenic intermediates, due to which the toxicity was reduced gradually, finally resulting in nearly complete detoxification.

  12. Differences in quantification of DNA double-strand breaks assessed by 53BP1/γH2AX focus formation assays and the comet assay in mammalian cells treated with irradiation and N-acetyl-L-cysteine.

    Science.gov (United States)

    Kurashige, Tomomi; Shimamura, Mika; Nagayama, Yuji

    2016-06-01

    The biological effect of ionizing radiation (IR) on genomic DNA is thought to be either direct or indirect; the latter is mediated by IR induction of free radicals and reactive oxygen species (ROS). This study was designed to evaluate the effect of N-acetyl-L-cysteine (NAC), a well-known ROS-scavenging antioxidant, on IR induction of genotoxicity, cytotoxicity and ROS production in mammalian cells, and aimed to clarify the conflicting data in previous publications. Although we clearly demonstrate the beneficial effect of NAC on IR-induced genotoxicity and cytotoxicity (determined using the micronucleus assay and cell viability/clonogenic assays), the data on NAC's effect on DNA double-strand break (DSB) formation were inconsistent in different assays. Specifically, mitigation of IR-induced DSBs by NAC was readily detected by the neutral comet assay, but not by the γH2AX or 53BP1 focus assays. NAC is a glutathione precursor and exerts its effect after conversion to glutathione, and presumably it has its own biological activity. Assuming that the focus assay reflects the biological responses to DSBs (detection and repair), while the comet assay reflects the physical status of genomic DNA, our results indicate that the comet assay could readily detect the antioxidant effect of NAC on DSB formation. However, NAC's biological effect might affect the detection of DSB repair by the focus assays. Our data illustrate that multiple parameters should be carefully used to analyze DNA damage when studying potential candidates for radioprotective compounds. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  13. A functional assay-based strategy for nanomaterial risk forecasting

    Energy Technology Data Exchange (ETDEWEB)

    Hendren, Christine Ogilvie, E-mail: christine.hendren@duke.edu [Center for the Environmental Implications of NanoTechnology, Duke University, Durham, NC 27708 (United States); Lowry, Gregory V., E-mail: glowry@andrew.cmu.edu [Center for the Environmental Implications of NanoTechnology, Duke University, Durham, NC 27708 (United States); Department of Civil and Environmental Engineering, Carnegie Mellon University, 119 Porter Hall, Pittsburgh, PA 15213 (United States); Unrine, Jason M., E-mail: jason.unrine@uky.edu [Center for the Environmental Implications of NanoTechnology, Duke University, Durham, NC 27708 (United States); Department of Plant and Soil Sciences, University of Kentucky, Agricultural Science Center, Lexington, KY 40546 (United States); Wiesner, Mark R., E-mail: wiesner@duke.edu [Center for the Environmental Implications of NanoTechnology, Duke University, Durham, NC 27708 (United States); Department of Civil and Environmental Engineering, Duke University, 121 Hudson Hall PO Box 90287, Durham, NC 27708 (United States)

    2015-12-01

    The study of nanomaterial impacts on environment, health and safety (nanoEHS) has been largely predicated on the assumption that exposure and hazard can be predicted from physical–chemical properties of nanomaterials. This approach is rooted in the view that nanoöbjects essentially resemble chemicals with additional particle-based attributes that must be included among their intrinsic physical–chemical descriptors. With the exception of the trivial case of nanomaterials made from toxic or highly reactive materials, this approach has yielded few actionable guidelines for predicting nanomaterial risk. This article addresses inherent problems in structuring a nanoEHS research strategy based on the goal of predicting outcomes directly from nanomaterial properties, and proposes a framework for organizing data and designing integrated experiments based on functional assays (FAs). FAs are intermediary, semi-empirical measures of processes or functions within a specified system that bridge the gap between nanomaterial properties and potential outcomes in complex systems. The three components of a functional assay are standardized protocols for parameter determination and reporting, a theoretical context for parameter application and reference systems. We propose the identification and adoption of reference systems where FAs may be applied to provide parameter estimates for environmental fate and effects models, as well as benchmarks for comparing the results of FAs and experiments conducted in more complex and varied systems. Surface affinity and dissolution rate are identified as two critical FAs for characterizing nanomaterial behavior in a variety of important systems. The use of these FAs to predict bioaccumulation and toxicity for initial and aged nanomaterials is illustrated for the case of silver nanoparticles and Caenorhabditis elegans. - Highlights: • Approaches to predict risk directly from nanomaterial (NM) properties are problematic. • We propose

  14. A functional assay-based strategy for nanomaterial risk forecasting

    International Nuclear Information System (INIS)

    Hendren, Christine Ogilvie; Lowry, Gregory V.; Unrine, Jason M.; Wiesner, Mark R.

    2015-01-01

    The study of nanomaterial impacts on environment, health and safety (nanoEHS) has been largely predicated on the assumption that exposure and hazard can be predicted from physical–chemical properties of nanomaterials. This approach is rooted in the view that nanoöbjects essentially resemble chemicals with additional particle-based attributes that must be included among their intrinsic physical–chemical descriptors. With the exception of the trivial case of nanomaterials made from toxic or highly reactive materials, this approach has yielded few actionable guidelines for predicting nanomaterial risk. This article addresses inherent problems in structuring a nanoEHS research strategy based on the goal of predicting outcomes directly from nanomaterial properties, and proposes a framework for organizing data and designing integrated experiments based on functional assays (FAs). FAs are intermediary, semi-empirical measures of processes or functions within a specified system that bridge the gap between nanomaterial properties and potential outcomes in complex systems. The three components of a functional assay are standardized protocols for parameter determination and reporting, a theoretical context for parameter application and reference systems. We propose the identification and adoption of reference systems where FAs may be applied to provide parameter estimates for environmental fate and effects models, as well as benchmarks for comparing the results of FAs and experiments conducted in more complex and varied systems. Surface affinity and dissolution rate are identified as two critical FAs for characterizing nanomaterial behavior in a variety of important systems. The use of these FAs to predict bioaccumulation and toxicity for initial and aged nanomaterials is illustrated for the case of silver nanoparticles and Caenorhabditis elegans. - Highlights: • Approaches to predict risk directly from nanomaterial (NM) properties are problematic. • We propose

  15. [3H]uridine uptake by target monolayers as a terminal label in an in vitro cell-mediated cytotoxicity assay

    International Nuclear Information System (INIS)

    Smith, G.; Nicklin, S.

    1979-01-01

    A terminal labelling method is described for measuring cell-mediated cytotoxicity based on the ability of surviving target cells to incorporate [ 3 H]uridine into their RNA precursor pools. Parameters of the system were examined using whole and damaged embryonic mouse fibroblast monolayers. This assay is less laborious than direct cell counting and gives increased sensitivity at low target to effector cell ratios. The labelling time is short and, unlike similar techniques, it allows target cell monolayers to remain intact after completion of the radioassay and available for histological examination. This is important where heterogeneous target populations are employed since it allows assessment of differential cell killing and eliminates the need for duplicate cultures. The assay was used in conjunction with a well defined mouse popliteal lymph node assay to investigate the appearance of cytotoxic cells during a localised graft versus host response. Results showed a direct correlation between proliferative index and the development of highly specific cell-mediated cytotoxicity. (Auth.)

  16. Ultrasensitive human thyrotropin (h TSH) immunoradiometric assay (IRMA) set up, through identification and minimization of non specific bindings; Ensaio imunoradiometrico ultra-sensivel de tireotrofina humana (hTSH) obtido mediante a identificacao e minimizacao de ligacoes inespecificas

    Energy Technology Data Exchange (ETDEWEB)

    Peroni, C N

    1994-12-31

    An IRMA of h TSH, based on magnetic solid phase separation, was studied especially for what concerns its non specific bindings. These were identified as a product of the interaction between an altered form of radioiodinated anti-h TSH monoclonal antibody ({sup 125} I-m AB) and the uncoupled magnetizable cellulose particle (matrix). Apparently this form of {sup 125} I-m AB is a type of aggregate that can be partly resolved from the main peak on Sephadex G-200 and further minimized via a single pre-incubation with the same matrix. Solid phase saturation with milk proteins, tracer storage at 4{sup 0} C and serum addition during incubation were also found particularly effective is preventing its formation. These findings were used in order to reproducibly decrease non specific bindings to values <0.1% (or <70 cpm), increasing thus the signal-to-noise ratio (B{sub 60}/B{sub O}) up to values of 300-500. This way we obtained h TSH radio assays with functional sensitivities of about 0.05 m IU/L and analytical sensitivities of the order of 0.02 m IU/L, which classify them at least as among the best second generation assays and that are excellent indeed for magnetic IRMA s. A more optimistic sensitivity calculation, based on Rodbard`s definition, provided values down to 0.008 m IU/L. Such sensitivities, moreover, were obtained in a very reproducible way and all over the useful tracer life. (author). 83 refs, 13 figs, 25 tabs.

  17. MS transport assays for γ-aminobutyric acid transporters--an efficient alternative for radiometric assays.

    Science.gov (United States)

    Schmitt, Sebastian; Höfner, Georg; Wanner, Klaus T

    2014-08-05

    Transport assays for neurotransmitters based on radiolabeled substrates are widely spread and often indispensable in basic research and the drug development process, although the use of radioisotopes is inherently coupled to issues concerning radioactive waste and safety precautions. To overcome these disadvantages, we developed mass spectrometry (MS)-based transport assays for γ-aminobutyric acid (GABA), which is the major inhibitory neurotransmitter in the central nervous system (CNS). These "MS Transport Assays" provide all capabilities of [(3)H]GABA transport assays and therefore represent the first substitute for the latter. The performance of our approach is demonstrated for GAT1, the most important GABA transporter (GAT) subtype. As GABA is endogenously present in COS-7 cells employed as hGAT1 expression system, ((2)H6)GABA was used as a substrate to differentiate transported from endogenous GABA. To record transported ((2)H6)GABA, a highly sensitive, short, robust, and reliable HILIC-ESI-MS/MS quantification method using ((2)H2)GABA as an internal standard was developed and validated according to the Center for Drug Evaluation and Research (CDER) guidelines. Based on this LC-MS quantification, a setup to characterize hGAT1 mediated ((2)H6)GABA transport in a 96-well format was established, that enables automated processing and avoids any sample preparation. The K(m) value for ((2)H6)GABA determined for hGAT1 is in excellent agreement with results obtained from [(3)H]GABA uptake assays. In addition, the established assay format enables efficient determination of the inhibitory potency of GAT1 inhibitors, is capable of identifying those inhibitors transported as substrates, and furthermore allows characterization of efflux. The approach described here combines the strengths of LC-MS/MS with the high efficiency of transport assays based on radiolabeled substrates and is applicable to all GABA transporter subtypes.

  18. Two-step versus one-step FT4 assays in heparin treated patients and non-thyroidal illness

    International Nuclear Information System (INIS)

    Reiners, C.; Bieler, G.; Ertl, G.; Gloss, H.; Boerner, W.

    1985-01-01

    The primary intention of this study is to inform the clinician about the direction and the order of magnitude of possible disturbances of different FT 4 parameters under the condition mentioned last, which is not uncommon in daily routine. No single FT 4 -RIA proved be valid in severe NTI. There is the risk to misinterprete hyperthyroidism as euthyroidism with 1step assays and the possibility to classify euthyroid patients falsely as hyperthyroid with 2step assays. In relation to this problem, the sometimes lowered FT 4 values by 1step methods are clinically not so important. It has to be established, wether TSH assays of high sensitivity are able to overcome some of the difficulties with determinations of peripheral thyroid hormones in NTI. (orig./MG)

  19. Clonogenic assay: adherent cells.

    Science.gov (United States)

    Rafehi, Haloom; Orlowski, Christian; Georgiadis, George T; Ververis, Katherine; El-Osta, Assam; Karagiannis, Tom C

    2011-03-13

    The clonogenic (or colony forming) assay has been established for more than 50 years; the original paper describing the technique was published in 1956. Apart from documenting the method, the initial landmark study generated the first radiation-dose response curve for X-ray irradiated mammalian (HeLa) cells in culture. Basically, the clonogenic assay enables an assessment of the differences in reproductive viability (capacity of cells to produce progeny; i.e. a single cell to form a colony of 50 or more cells) between control untreated cells and cells that have undergone various treatments such as exposure to ionising radiation, various chemical compounds (e.g. cytotoxic agents) or in other cases genetic manipulation. The assay has become the most widely accepted technique in radiation biology and has been widely used for evaluating the radiation sensitivity of different cell lines. Further, the clonogenic assay is commonly used for monitoring the efficacy of radiation modifying compounds and for determining the effects of cytotoxic agents and other anti-cancer therapeutics on colony forming ability, in different cell lines. A typical clonogenic survival experiment using adherent cells lines involves three distinct components, 1) treatment of the cell monolayer in tissue culture flasks, 2) preparation of single cell suspensions and plating an appropriate number of cells in petri dishes and 3) fixing and staining colonies following a relevant incubation period, which could range from 1-3 weeks, depending on the cell line. Here we demonstrate the general procedure for performing the clonogenic assay with adherent cell lines with the use of an immortalized human keratinocyte cell line (FEP-1811). Also, our aims are to describe common features of clonogenic assays including calculation of the plating efficiency and survival fractions after exposure of cells to radiation, and to exemplify modification of radiation-response with the use of a natural antioxidant

  20. Application of Peptide Nucleic Acid-based Assays Toward Detection of Somatic Mosaicism

    Directory of Open Access Journals (Sweden)

    Christopher S Hong

    2016-01-01

    Full Text Available Peptide nucleic acids (PNAs are synthetic oligonucleotides with many applications. Compared with DNA, PNAs bind their complementary DNA strand with higher specificity and strength, an attribute that can make it an effective polymerase chain reaction clamp. A growing body of work has demonstrated the utility of PNAs in detecting low levels of mutant DNA, particularly in the detection of circulating mutated tumor cells in the peripheral blood. The PNA-based assay has greater sensitivity than direct sequencing and is significantly more affordable and rapid than next-generation deep sequencing. We have previously demonstrated that PNAs can successfully detect somatic mosaicism in patients with suspected disease phenotypes. In this report, we detail our methodology behind PNA design and application. We describe our protocol for optimizing the PNA for sequencing use and for determining the sensitivity of the PNA-based assay. Lastly, we discuss the potential applications of our assay for future laboratory and clinical purposes and highlight the role of PNAs in the detection of somatic mosaicism.

  1. Genotoxicity testing: Comparison of the γH2AX focus assay with the alkaline and neutral comet assays.

    Science.gov (United States)

    Nikolova, Teodora; Marini, Federico; Kaina, Bernd

    2017-10-01

    Genotoxicity testing relies on the quantitative measurement of adverse effects, such as chromosome aberrations, micronuclei, and mutations, resulting from primary DNA damage. Ideally, assays will detect DNA damage and cellular responses with high sensitivity, reliability, and throughput. Several novel genotoxicity assays may fulfill these requirements, including the comet assay and the more recently developed γH2AX assay. Although they are thought to be specific for genotoxicants, a systematic comparison of the assays has not yet been undertaken. In the present study, we compare the γH2AX focus assay with the alkaline and neutral versions of the comet assay, as to their sensitivities and limitations for detection of genetic damage. We investigated the dose-response relationships of γH2AX foci and comet tail intensities at various times following treatment with four prototypical genotoxicants, methyl methanesulfonate (MMS), N-methyl-N'-nitro-N-nitrosoguanidine (MNNG), mitomycin C, and hydrogen peroxide (H 2 O 2 ) and we tested whether there is a correlation between the endpoints, i.e., alkali-labile sites and DNA strand breaks on the one hand and the cell's response to DNA double-strand breaks and blocked replication forks on the other. Induction of γH2AX foci gave a linear dose response and all agents tested were positive in the assay. The increase in comet tail intensity was also a function of dose; however, mitomycin C was almost completely ineffective in the comet assay, and the doses needed to achieve a significant effect were somewhat higher for some treatments in the comet assay than in the γH2AX foci assay, which was confirmed by threshold analysis. There was high correlation between tail intensity and γH2AX foci for MMS and H 2 O 2 , less for MNNG, and none for mitomycin C. From this we infer that the γH2AX foci assay is more reliable, sensitive, and robust than the comet assay for detecting genotoxicant-induced DNA damage. Copyright © 2017 Elsevier

  2. A versatile electrowetting-based digital microfluidic platform for quantitative homogeneous and heterogeneous bio-assays

    Science.gov (United States)

    Vergauwe, Nicolas; Witters, Daan; Ceyssens, Frederik; Vermeir, Steven; Verbruggen, Bert; Puers, Robert; Lammertyn, Jeroen

    2011-05-01

    Electrowetting-on-dielectric (EWOD) lab-on-a-chip systems have already proven their potential within a broad range of bio-assays. Nevertheless, research on the analytical performance of those systems is limited, yet crucial for a further breakthrough in the diagnostic field. Therefore, this paper presents the intrinsic possibilities of an EWOD lab-on-a-chip as a versatile platform for homogeneous and heterogeneous bio-assays with high analytical performance. Both droplet dispensing and splitting cause variations in droplet size, thereby directly influencing the assay's performance. The extent to which they influence the performance is assessed by a theoretical sensitivity analysis, which allows the definition of a basic framework for the reduction of droplet size variability. Taking advantage of the optimized droplet manipulations, both homogeneous and heterogeneous bio-assays are implemented in the EWOD lab-on-a-chip to demonstrate the analytical capabilities and versatility of the device. A fully on-chip enzymatic assay is realized with high analytical performance. It demonstrates the promising capabilities of an EWOD lab-on-a-chip in food-related and medical applications, such as nutritional and blood analyses. Further, a magnetic bio-assay for IgE detection using superparamagnetic nanoparticles is presented whereby the nanoparticles are used as solid carriers during the bio-assay. Crucial elements are the precise manipulation of the superparamagnetic nanoparticles with respect to dispensing and separation. Although the principle of using nano-carriers is demonstrated for protein detection, it can be easily extended to a broader range of bio-related applications like DNA sensing. In heterogeneous bio-assays the chip surface is actively involved during the execution of the bio-assay. Through immobilization of specific biological compounds like DNA, proteins and cells a reactive chip surface is realized, which enhances the bio-assay performance. To demonstrate

  3. Enzyme activity assay of glycoprotein enzymes based on a boronate affinity molecularly imprinted 96-well microplate.

    Science.gov (United States)

    Bi, Xiaodong; Liu, Zhen

    2014-12-16

    Enzyme activity assay is an important method in clinical diagnostics. However, conventional enzyme activity assay suffers from apparent interference from the sample matrix. Herein, we present a new format of enzyme activity assay that can effectively eliminate the effects of the sample matrix. The key is a 96-well microplate modified with molecularly imprinted polymer (MIP) prepared according to a newly proposed method called boronate affinity-based oriented surface imprinting. Alkaline phosphatase (ALP), a glycoprotein enzyme that has been routinely used as an indicator for several diseases in clinical tests, was taken as a representative target enzyme. The prepared MIP exhibited strong affinity toward the template enzyme (with a dissociation constant of 10(-10) M) as well as superb tolerance for interference. Thus, the enzyme molecules in a complicated sample matrix could be specifically captured and cleaned up for enzyme activity assay, which eliminated the interference from the sample matrix. On the other hand, because the boronate affinity MIP could well retain the enzymatic activity of glycoprotein enzymes, the enzyme captured by the MIP was directly used for activity assay. Thus, additional assay time and possible enzyme or activity loss due to an enzyme release step required by other methods were avoided. Assay of ALP in human serum was successfully demonstrated, suggesting a promising prospect of the proposed method in real-world applications.

  4. Operational impact of using a vanadate oxidase method for direct bilirubin measurements at an academic medical center clinical laboratory

    Directory of Open Access Journals (Sweden)

    Neha Dhungana

    2017-08-01

    Full Text Available Objectives: The aim of this study was to compare the operational impact of using vanadate oxidase versus diazo direct bilirubin assays for an academic medical center patient population. Design and methods: Retrospective study was done over an approximately 3.5 year period. The main automated chemistry instrumentation was a Roche Diagnostics cobas 8000 line. The Roche Direct Bilirubin assay was compared to Diazyme Laboratories Direct Bilirubin Assay and Randox Laboratories Direct Bilirubin assay using manufacturer's guidelines for hemolysis index, lipemia index, and analytical measurement range (AMR. Results: Retrospective data was analyzed for 47,333 serum/plasma specimens that had clinical orders for direct bilirubin. A total of 5943 specimens (12.6% exceeded the hemolysis index limit for the Roche method compared to only 0.2% and 0.05% of specimens for the Diazyme and Randox methods, respectively. The impact was particularly large on patients less than 2 years old, for which 51.3% of specimens exceeded the hemolysis index for the Roche method. A total of 1671 specimens (3.5% exceeded the lipemia index limit for the Roche method compared to less than 0.1% for the Randox method. Lastly, 988 (2.1% of specimens had direct bilirubin concentrations exceeding the upper AMR limit of 10 mg/dL [171 µmol/L] for the Roche assay compared to less than 1% of specimens for the vanadate oxidase methods. Conclusions: Vanadate oxidase direct bilirubin methods offer advantages over diazo methods in terms of less interference by hemolysis and lipemia, as well as wider AMR. The advantages are particularly evident for neonatal and infant populations. Keywords: Bilirubin, Clinical chemistry tests, Hemolysis, Hyperlipidemias, Jaundice, Photometry

  5. A Simple and Sensitive High-Content Assay for the Characterization of Antiproliferative Therapeutic Antibodies.

    Science.gov (United States)

    Stengl, Andreas; Hörl, David; Leonhardt, Heinrich; Helma, Jonas

    2017-03-01

    Monoclonal antibodies (mAbs) have become a central class of therapeutic agents in particular as antiproliferative compounds. Their often complex modes of action require sensitive assays during early, functional characterization. Current cell-based proliferation assays often detect metabolites that are indicative of metabolic activity but do not directly account for cell proliferation. Measuring DNA replication by incorporation of base analogues such as 5-bromo-2'-deoxyuridine (BrdU) fills this analytical gap but was previously restricted to bulk effect characterization in enzyme-linked immunosorbent assay formats. Here, we describe a cell-based assay format for the characterization of antiproliferative mAbs regarding potency and mode of action in a single experiment. The assay makes use of single cell-based high-content-analysis (HCA) for the reliable quantification of replicating cells and DNA content via 5-ethynyl-2'-deoxyuridine (EdU) and 4',6-diamidino-2-phenylindole (DAPI), respectively, as sensitive measures of antiproliferative mAb activity. We used trastuzumab, an antiproliferative therapeutic antibody interfering with HER2 cell surface receptor-mediated growth signal transduction, and HER2-overexpressing cell lines BT474 and SKBR3 to demonstrate up to 10-fold signal-to-background (S/B) ratios for treated versus untreated cells and a shift in cell cycle profiles indicating antibody-induced cell cycle arrest. The assay is simple, cost-effective, and sensitive, providing a cell-based format for preclinical characterization of therapeutic mAbs.

  6. Multicentre comparison of a diagnostic assay

    DEFF Research Database (Denmark)

    Waters, Patrick; Reindl, Markus; Saiz, Albert

    2016-01-01

    ) assays in neuromyelitis optica spectrum disorders (NMOSD). METHODS: Coded samples from patients with neuromyelitis optica (NMO) or NMOSD (101) and controls (92) were tested at 15 European diagnostic centres using 21 assays including live (n=3) or fixed cell-based assays (n=10), flow cytometry (n=4...

  7. Evaluation of the Cepheid Xpert MTB/RIF Assay for Direct Detection of Mycobacterium tuberculosis Complex in Respiratory Specimens▿

    Science.gov (United States)

    Marlowe, Elizabeth M.; Novak-Weekley, Susan M.; Cumpio, Joven; Sharp, Susan E.; Momeny, Michelle A.; Babst, Anna; Carlson, Jonathan S.; Kawamura, Masae; Pandori, Mark

    2011-01-01

    A total of 217 specimens submitted for routine smear and culture from three different sites within the western United States were used to evaluate the GeneXpert MTB/RIF assay (for research use only) (Cepheid, Sunnyvale, CA). Overall agreement compared to culture was 89% (98% for smear positives and 72% for smear negatives) for detection of Mycobacterium tuberculosis. PMID:21289151

  8. A tissue biopsy-based epigenetic multiplex PCR assay for prostate cancer detection

    Directory of Open Access Journals (Sweden)

    Van Neste Leander

    2012-06-01

    Full Text Available Abstract Background PSA-directed prostate cancer screening leads to a high rate of false positive identifications and an unnecessary biopsy burden. Epigenetic biomarkers have proven useful, exhibiting frequent and abundant inactivation of tumor suppressor genes through such mechanisms. An epigenetic, multiplex PCR test for prostate cancer diagnosis could provide physicians with better tools to help their patients. Biomarkers like GSTP1, APC and RASSF1 have demonstrated involvement with prostate cancer, with the latter two genes playing prominent roles in the field effect. The epigenetic states of these genes can be used to assess the likelihood of cancer presence or absence. Results An initial test cohort of 30 prostate cancer-positive samples and 12 cancer-negative samples was used as basis for the development and optimization of an epigenetic multiplex assay based on the GSTP1, APC and RASSF1 genes, using methylation specific PCR (MSP. The effect of prostate needle core biopsy sample volume and age of formalin-fixed paraffin-embedded (FFPE samples was evaluated on an independent follow-up cohort of 51 cancer-positive patients. Multiplexing affects copy number calculations in a consistent way per assay. Methylation ratios are therefore altered compared to the respective singleplex assays, but the correlation with patient outcome remains equivalent. In addition, tissue-biopsy samples as small as 20 μm can be used to detect methylation in a reliable manner. The age of FFPE-samples does have a negative impact on DNA quality and quantity. Conclusions The developed multiplex assay appears functionally similar to individual singleplex assays, with the benefit of lower tissue requirements, lower cost and decreased signal variation. This assay can be applied to small biopsy specimens, down to 20 microns, widening clinical applicability. Increasing the sample volume can compensate the loss of DNA quality and quantity in older samples.

  9. Comet Assay on Daphnia magna in eco-genotoxicity testing.

    Science.gov (United States)

    Pellegri, Valerio; Gorbi, Gessica; Buschini, Annamaria

    2014-10-01

    Detection of potentially hazardous compounds in water bodies is a priority in environmental risk assessment. For the evaluation and monitoring of water quality, a series of methodologies may be applied. Among them, the worldwide used toxicity tests with organisms of the genus Daphnia is one of the most powerful. In recent years, some attempts were made to utilize Daphnia magna in genotoxicity testing as many of the new environmental contaminants are described as DNA-damaging agents in aquatic organisms. The aim of this research was to develop a highly standardized protocol of the Comet Assay adapted for D. magna, especially regarding the isolation of cells derived from the same tissue (haemolymph) from newborn organisms exposed in vivo. Several methods for haemolymph extraction and different Comet Assay parameters were compared. Electrophoretic conditions were adapted in order to obtain minimum DNA migration in cells derived from untreated organisms and, at the same time, maximum sensitivity in specimens treated with known genotoxicants (CdCl2 and H2O2). Additional tests were performed to investigate if life-history traits of the cladoceran (such as the age of adult organisms that provide newborns, the clutch size of origin, the number of generations reared in standard conditions) and the water composition as well, might influence the response of the assay. This study confirms the potential application of the Comet Assay in D. magna for assessing genotoxic loads in aqueous solution. The newly developed protocol could integrate the acute toxicity bioassay, thus expanding the possibility of using this model species in freshwater monitoring (waters, sediment and soil elutriates) and is in line with the spirit of the EU Water Framework Directive in reducing the number of bioassays that involve medium-sized species. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Nondestructive assay technology and automated ''real-time'' materials control

    International Nuclear Information System (INIS)

    Keepin, G.R.

    1977-01-01

    Significant advances in nondestructive assay techniques and instrumentation now enable rapid, accurate and direct in-plant measurement of nuclear material on a continuous or ''real-time'' basis as it progresses through a nuclear facility. A variety of passive and active assay instruments are required for the broad range of materials measurement problems encountered by safeguards inspectors and facility operators in various types of nuclear plants. Representative NDA techniques and instruments are presented and reviewed with special attention to their assay capabilities and areas of applicability in the nuclear fuel cycle. An advanced system of materials control - called ''DYMAC'', for Dynamic Materials Control - is presently under development by the U.S. Energy Research and Development Administration; the DYMAC program integrates new nondestructive assay instrumentation and modern data-processing methods, with the overall objective of demonstrating a workable, cost-effective system of stringent safeguards and materials control in various generic types of facilities found in the nuclear fuel cycle. Throughout the program, emphasis will be placed on devloping practical solutions to generic measurement problems so that resulting techniques and instrumentation will have widespread utility. Projected levels of safeguards assurance, together with other vital - and cost-sensitive - plant operational factors such as process and quality control, criticality safety and waste management are examined in an evaluation of the impact of future advanced materials control systems on overall plant operations, efficiency and productivity. The task of implementing effective and stringent safeguards includes the transfer of new safeguards technology to the nuclear industry. Clearly the training of inspectors (both IAEA and national), plant people, etc., in the effective use of new NDA equipment is of paramount importance; thus in the United States, the Energy Research and Development

  11. Radioreceptor assay for insulin

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Kazuo [Tokyo Univ. (Japan). Faculty of Medicine

    1975-04-01

    Radioreceptor assay of insulin was discussed from the aspects of the measuring method, its merits and problems to be solved, and its clinical application. Rat liver 10 x g pellet was used as receptor site, and enzymatic degradation of insulin by the system contained in this fraction was inhibited by adding 1 mM p-CMB. /sup 125/I-labelled porcine insulin was made by lactoperoxidase method under overnight incubation at 4/sup 0/C and later purification by Sephadex G-25 column and Whatman CF-11 cellulose powder. Dog pancreatic vein serum insulin during and after the glucose load was determined by radioreceptor assay and radioimmunoassay resulting that both measurements accorded considerably. Radioreceptor assay would clarify the pathology of disorders of glucose metabolism including diabetes.

  12. Nano-immunosafety: issues in assay validation

    International Nuclear Information System (INIS)

    Boraschi, Diana; Italiani, Paola; Oostingh, Gertie J; Duschl, Albert; Casals, Eudald; Puntes, Victor F; Nelissen, Inge

    2011-01-01

    Assessing the safety of engineered nanomaterials for human health must include a thorough evaluation of their effects on the immune system, which is responsible for defending the integrity of our body from damage and disease. An array of robust and representative assays should be set up and validated, which could be predictive of the effects of nanomaterials on immune responses. In a trans-European collaborative work, in vitro assays have been developed to this end. In vitro tests have been preferred for their suitability to standardisation and easier applicability. Adapting classical assays to testing the immunotoxicological effects of nanoparticulate materials has raised a series of issues that needed to be appropriately addressed in order to ensure reliability of results. Besides the exquisitely immunological problem of selecting representative endpoints predictive of the risk of developing disease, assay results turned out to be significantly biased by artefactual interference of the nanomaterials or contaminating agents with the assay protocol. Having addressed such problems, a series of robust and representative assays have been developed that describe the effects of engineered nanoparticles on professional and non-professional human defence cells. Two of such assays are described here, one based on primary human monocytes and the other employing human lung epithelial cells transfected with a reporter gene.

  13. Data transformation methods for multiplexed assays

    Science.gov (United States)

    Tammero, Lance F. Bentley; Dzenitis, John M; Hindson, Benjamin J

    2013-07-23

    Methods to improve the performance of an array assay are described. A correlation between fluorescence intensity-related parameters and negative control values of the assay is determined. The parameters are then adjusted as a function of the correlation. As a result, sensitivity of the assay is improved without changes in its specificity.

  14. Community Laboratory Testing for Cryptosporidium: Multicenter Study Retesting Public Health Surveillance Stool Samples Positive for Cryptosporidium by Rapid Cartridge Assay with Direct Fluorescent Antibody Testing.

    Directory of Open Access Journals (Sweden)

    Dawn M Roellig

    Full Text Available Cryptosporidium is a common cause of sporadic diarrheal disease and outbreaks in the United States. Increasingly, immunochromatography-based rapid cartridge assays (RCAs are providing community laboratories with a quick cryptosporidiosis diagnostic method. In the current study, the Centers for Disease Control and Prevention (CDC, the Association of Public Health Laboratories (APHL, and four state health departments evaluated RCA-positive samples obtained during routine Cryptosporidium testing. All samples underwent "head to head" re-testing using both RCA and direct fluorescence assay (DFA. Community level results from three sites indicated that 54.4% (166/305 of Meridian ImmunoCard STAT! positives and 87.0% (67/77 of Remel Xpect positives were confirmed by DFA. When samples were retested by RCA at state laboratories and compared with DFA, 83.3% (155/186 of Meridian ImmunoCard STAT! positives and 95.2% (60/63 of Remel Xpect positives were confirmed. The percentage of confirmed community results varied by site: Minnesota, 39.0%; New York, 63.9%; and Wisconsin, 72.1%. The percentage of confirmed community results decreased with patient age; 12.5% of community positive tests could be confirmed by DFA for patients 60 years of age or older. The percentage of confirmed results did not differ significantly by sex, storage temperature, time between sample collection and testing, or season. Findings from this study demonstrate a lower confirmation rate of community RCA positives when compared to RCA positives identified at state laboratories. Elucidating the causes of decreased test performance in order to improve overall community laboratory performance of these tests is critical for understanding the epidemiology of cryptosporidiosis in the United States (US.

  15. A rapid qualitative assay for detection of Clostridium perfringens in canned food products.

    Science.gov (United States)

    Dave, Gayatri Ashwinkumar

    2017-01-01

    Clostridium perfringens (MTCC 1349) is a Gram-positive, anaerobic, endospore forming, and rod-shaped bacterium. This bacterium produces a variety of toxins under strict anaerobic environment. C. perfringens can grow at temperatures ranging between 20°C and 50°C. It is the major causetive agent for gas gangrene, cellulitis, septicemia, necrotic enteritis and food poisoning, which are common toxin induced conditions noted in human and animals. C. perfringens can produce produce four major types of toxins that are used for the classification of strains, classified under type A-E. Across the globe many countries, including the United States, are affected by C. perfringens food poisonings where it is ranked as one of the most common causes of food borne infections. To date, no direct one step assay for the detection of C. perfringens has been developed and only few methods are known for accurate detection of C. perfringens. Long detection and incubation time is the major consideration of these reporter assays. The prensent study proposes a rapid and reliable colorimetric assay for the detection of C. perfringens. In principale, this assay detects the para nitrophenyl (yellow colour end product) liberated due to the hydrolysis of paranitrophenyl phosphetidyl choline (PNPC) through phospholipase C (lecithinase). Constitutive secretion of phospholipase C is a charactristic feature of C. perfringens. This assay detects the presence of the extracellular lecithinse through the PNPC impragnated impregnated probe. The probe is impregnated with peranitrophenyl phosphotidyl choline ester, which is colourless substrate used by lecithinase. The designed assay is specific towards PNPC and detectes very small quantites of lecithinase under conditions used. The reaction is substrate specific, no cross reaction was observed upon incubation with other substrates. In addition, this assay gave negative results with other clostridium strains, no cross reactions were observed with other

  16. Molecular surveillance of true nontypeable Haemophilus influenzae: an evaluation of PCR screening assays.

    Science.gov (United States)

    Binks, Michael J; Temple, Beth; Kirkham, Lea-Ann; Wiertsema, Selma P; Dunne, Eileen M; Richmond, Peter C; Marsh, Robyn L; Leach, Amanda J; Smith-Vaughan, Heidi C

    2012-01-01

    Unambiguous identification of nontypeable Haemophilus influenzae (NTHi) is not possible by conventional microbiology. Molecular characterisation of phenotypically defined NTHi isolates suggests that up to 40% are Haemophilus haemolyticus (Hh); however, the genetic similarity of NTHi and Hh limits the power of simple molecular techniques such as PCR for species discrimination. Here we assess the ability of previously published and novel PCR-based assays to identify true NTHi. Sixty phenotypic NTHi isolates, classified by a dual 16S rRNA gene PCR algorithm as NTHi (n = 22), Hh (n = 27) or equivocal (n = 11), were further characterised by sequencing of the 16S rRNA and recA genes then interrogated by PCR-based assays targeting the omp P2, omp P6, lgtC, hpd, 16S rRNA, fucK and iga genes. The sequencing data and PCR results were used to define NTHi for this study. Two hpd real time PCR assays (hpd#1 and hpd#3) and the conventional iga PCR assay were equally efficient at differentiating study-defined NTHi from Hh, each with a receiver operator characteristic curve area of 0.90 [0.83; 0.98]. The hpd#1 and hpd#3 assays were completely specific against a panel of common respiratory bacteria, unlike the iga PCR, and the hpd#3 assay was able to detect below 10 copies per reaction. Our data suggest an evolutionary continuum between NTHi and Hh and therefore no single gene target could completely differentiate NTHi from Hh. The hpd#3 real time PCR assay proved to be the superior method for discrimination of NTHi from closely related Haemophilus species with the added potential for quantification of H. influenzae directly from specimens. We suggest the hpd#3 assay would be suitable for routine NTHi surveillance and to assess the impact of antibiotics and vaccines, on H. influenzae carriage rates, carriage density, and disease.

  17. Molecular surveillance of true nontypeable Haemophilus influenzae: an evaluation of PCR screening assays.

    Directory of Open Access Journals (Sweden)

    Michael J Binks

    Full Text Available BACKGROUND: Unambiguous identification of nontypeable Haemophilus influenzae (NTHi is not possible by conventional microbiology. Molecular characterisation of phenotypically defined NTHi isolates suggests that up to 40% are Haemophilus haemolyticus (Hh; however, the genetic similarity of NTHi and Hh limits the power of simple molecular techniques such as PCR for species discrimination. METHODOLOGY/PRINCIPAL FINDINGS: Here we assess the ability of previously published and novel PCR-based assays to identify true NTHi. Sixty phenotypic NTHi isolates, classified by a dual 16S rRNA gene PCR algorithm as NTHi (n = 22, Hh (n = 27 or equivocal (n = 11, were further characterised by sequencing of the 16S rRNA and recA genes then interrogated by PCR-based assays targeting the omp P2, omp P6, lgtC, hpd, 16S rRNA, fucK and iga genes. The sequencing data and PCR results were used to define NTHi for this study. Two hpd real time PCR assays (hpd#1 and hpd#3 and the conventional iga PCR assay were equally efficient at differentiating study-defined NTHi from Hh, each with a receiver operator characteristic curve area of 0.90 [0.83; 0.98]. The hpd#1 and hpd#3 assays were completely specific against a panel of common respiratory bacteria, unlike the iga PCR, and the hpd#3 assay was able to detect below 10 copies per reaction. CONCLUSIONS/SIGNIFICANCE: Our data suggest an evolutionary continuum between NTHi and Hh and therefore no single gene target could completely differentiate NTHi from Hh. The hpd#3 real time PCR assay proved to be the superior method for discrimination of NTHi from closely related Haemophilus species with the added potential for quantification of H. influenzae directly from specimens. We suggest the hpd#3 assay would be suitable for routine NTHi surveillance and to assess the impact of antibiotics and vaccines, on H. influenzae carriage rates, carriage density, and disease.

  18. Peri-operative troponin monitoring using a prototype high-sensitivity cardiac troponin I (hs-cTnI) assay: comparisons with hs-cTnT and contemporary cTnI assays.

    LENUS (Irish Health Repository)

    Lee, Graham R

    2013-09-18

    Non-cardiac surgery is associated with major vascular complications and higher incidences of elevated plasma troponin (cTn) concentration. Goal-directed therapy (GDT) is a stroke volume (SV)-guided approach to intravenous (IV) fluid therapy that improves tissue perfusion, oxygenation and reduces post-operative complications. In patients undergoing major gastro-intestinal surgery, we compared high sensitive and contemporary troponin assays and correlated results with patient outcome.

  19. Spectrophotometric Enzyme Assays for High-Throughput Screening

    Directory of Open Access Journals (Sweden)

    Jean-Louis Reymond

    2004-01-01

    Full Text Available This paper reviews high-throughput screening enzyme assays developed in our laboratory over the last ten years. These enzyme assays were initially developed for the purpose of discovering catalytic antibodies by screening cell culture supernatants, but have proved generally useful for testing enzyme activities. Examples include TLC-based screening using acridone-labeled substrates, fluorogenic assays based on the β-elimination of umbelliferone or nitrophenol, and indirect assays such as the back-titration method with adrenaline and the copper-calcein fluorescence assay for aminoacids.

  20. Protein Analytical Assays for Diagnosing, Monitoring, and Choosing Treatment for Cancer Patients

    Directory of Open Access Journals (Sweden)

    Alicia D. Powers

    2012-01-01

    Full Text Available Cancer treatment is often hindered by inadequate methods for diagnosing the disease or insufficient predictive capacity regarding therapeutic efficacy. Targeted cancer treatments, including Bcr-Abl and EGFR kinase inhibitors, have increased survival for some cancer patients but are ineffective in other patients. In addition, many patients who initially respond to targeted inhibitor therapy develop resistance during the course of treatment. Molecular analysis of cancer cells has emerged as a means to tailor treatment to particular patients. While DNA analysis can provide important diagnostic information, protein analysis is particularly valuable because proteins are more direct mediators of normal and diseased cellular processes. In this review article, we discuss current and emerging protein assays for improving cancer treatment, including trends toward assay miniaturization and measurement of protein activity.

  1. The IRIDICA BAC BSI Assay: Rapid, Sensitive and Culture-Independent Identification of Bacteria and Candida in Blood

    Science.gov (United States)

    Rothman, Richard E.; Peterson, Stephen; Carroll, Karen C.; Zhang, Sean X.; Avornu, Gideon D.; Rounds, Megan A.; Carolan, Heather E.; Toleno, Donna M.; Moore, David; Hall, Thomas A.; Massire, Christian; Richmond, Gregory S.; Gutierrez, Jose R.; Sampath, Rangarajan; Ecker, David J.; Blyn, Lawrence B.

    2016-01-01

    Bloodstream infection (BSI) and sepsis are rising in incidence throughout the developed world. The spread of multi-drug resistant organisms presents increasing challenges to treatment. Surviving BSI is dependent on rapid and accurate identification of causal organisms, and timely application of appropriate antibiotics. Current culture-based methods used to detect and identify agents of BSI are often too slow to impact early therapy and may fail to detect relevant organisms in many positive cases. Existing methods for direct molecular detection of microbial DNA in blood are limited in either sensitivity (likely the result of small sample volumes) or in breadth of coverage, often because the PCR primers and probes used target only a few specific pathogens. There is a clear unmet need for a sensitive molecular assay capable of identifying the diverse bacteria and yeast associated with BSI directly from uncultured whole blood samples. We have developed a method of extracting DNA from larger volumes of whole blood (5 ml per sample), amplifying multiple widely conserved bacterial and fungal genes using a mismatch- and background-tolerant PCR chemistry, and identifying hundreds of diverse organisms from the amplified fragments on the basis of species-specific genetic signatures using electrospray ionization mass spectrometry (PCR/ESI-MS). We describe the analytical characteristics of the IRIDICA BAC BSI Assay and compare its pre-clinical performance to current standard-of-care methods in a collection of prospectively collected blood specimens from patients with symptoms of sepsis. The assay generated matching results in 80% of culture-positive cases (86% when common contaminants were excluded from the analysis), and twice the total number of positive detections. The described method is capable of providing organism identifications directly from uncultured blood in less than 8 hours. Disclaimer: The IRIDICA BAC BSI Assay is not available in the United States. PMID:27384540

  2. Preparation of directly iodinated steroid hormones and related directly halogenated compounds

    International Nuclear Information System (INIS)

    Sahadevan, V.

    1981-01-01

    The preparation of directly iodinated radioactive steroid hormones is described for use in radioimmunoassays or radiolocalization and treatment of human breast tumours. The radioactive iodinated steroid hormone is prepared by reacting a parent steroid hormone with an alkali metal iodide containing radioactive 123 I, 125 I, 130 I or 131 I in the presence of hydrogen peroxide or chloramine-T. The parent steroid hormones include the adrenal corticosteroids, the estrogens, the progestogens, the progestins and the diuretic and antidiuretic agents. The radioactive iodinated steroid hormone is prepared by iodinating the parent steroid hormone directly on the cyclopentanophenanthrene nucleus. The radioactive iodinated steroid hormones have the same antigenicity and receptor site specificity as the parent steroid hormone. The invention is illustrated by 1) the method of iodination of estradiol-17β, 2) results for the percentage labelling of several steroids and steroid hormones, 3) results for the radioimmunoassay of 125 I-estradiol and 4) results for the binding of directly iodinated estradiol-17β in an estrogen receptor assay of human breast cancer. (U.K.)

  3. RAS - Screens & Assays - Drug Discovery

    Science.gov (United States)

    The RAS Drug Discovery group aims to develop assays that will reveal aspects of RAS biology upon which cancer cells depend. Successful assay formats are made available for high-throughput screening programs to yield potentially effective drug compounds.

  4. Soil Baiting, Rapid PCR Assay and Quantitative Real Time PCR to Diagnose Late Blight of Potato in Quarantine Programs

    Directory of Open Access Journals (Sweden)

    Touseef Hussain

    2018-05-01

    Full Text Available Phytophthora infestans (mont de Bary is a pathogen of great concern across the globe, and accurate detection is an important component in responding to the outbreaks of potential disease. Although the molecular diagnostic protocol used in regulatory programs has been evaluated but till date methods implying direct comparison has rarely used. In this study, a known area soil samples from potato fields where light blight appear every year (both A1 and A2 mating type was assayed by soil bait method, PCR assay detection and quantification of the inoculums. Suspected disease symptoms appeared on bait tubers were further confirmed by rapid PCR, inoculums were quantified through Real Time PCR, which confirms presence of P. infestans. These diagnostic methods can be highly correlated with one another. Potato tuber baiting increased the sensitivity of the assay compared with direct extraction of DNA from tuber and soil samples. Our study determines diagnostic sensitivity and specificity of the assays to determine the performance of each method. Overall, molecular techniques based on different types of PCR amplification and Real-time PCR can lead to high throughput, faster and more accurate detection method which can be used in quarantine programmes in potato industry and diagnostic laboratory.

  5. Radioimmunoassays and related procedures in the diagnosis of parasitic infections

    International Nuclear Information System (INIS)

    Dessaint, J.P.; Cesbron, J.Y.; Lutsch, C.; Nogueira-Queiroz, J.A.; Capron, A.

    1986-01-01

    Immunological tests for the diagnosis of parasitic infections have long been used, yet the marked variability in seroreactivity of infected patients is still a challenge to immunoparasitologists. In the case of helminth parasites, especially schistosomes and filariae, immunoassays have benefited by numerous advances in the characterization and purification of antigens and by the use of monoclonal antibodies. The identification of functional antigens allows the detection of putative protective (or blocking) antibody responses by competitive RIAs using monoclonal antibodies in schistosomiasis. While progress has been made in the investigation of immunity in man, immunoassays for antibodies do not accurately correlate with parasite load, especially at lower antibody responses or after chemotherapy. Immunoassays for circulating parasite antigens have received much attention in recent years. Immunoradiometric assays and related procedures using infection sera or monoclonal antibodies are now being investigated in field conditions. Cross-reactions among circulating antigens from different parasites can decrease the specificity of such assays, whereas circulating immune complexes can interfere with the test. The recent use of RIAs to measure parasite antigens in the urine of patients with schistosomiasis or filariasis appears a promising approach. (author)

  6. The fluorometric microculture cytotoxicity assay.

    Science.gov (United States)

    Lindhagen, Elin; Nygren, Peter; Larsson, Rolf

    2008-01-01

    The fluorometric microculture cytotoxicity assay (FMCA) is a nonclonogenic microplate-based cell viability assay used for measurement of the cytotoxic and/or cytostatic effect of different compounds in vitro. The assay is based on hydrolysis of the probe, fluorescein diacetate (FDA) by esterases in cells with intact plasma membranes. The assay is available as both a semiautomated 96-well plate setup and a 384-well plate version fully adaptable to robotics. Experimental plates are prepared with a small amount of drug solution and can be stored frozen. Cells are seeded on the plates and cell viability is evaluated after 72 h. The protocol described here is applicable both for cell lines and freshly prepared tumor cells from patients and is suitable both for screening in drug development and as a basis for a predictive test for individualization of anticancer drug therapy.

  7. Solution assay instrument operations manual

    International Nuclear Information System (INIS)

    Li, T.K.; Marks, T.; Parker, J.L.

    1983-09-01

    An at-line solution assay instrument (SAI) has been developed and installed in a plutonium purification and americium recovery process area in the Los Alamos Plutonium Processing Facility. The instrument was designed for accurate, timely, and simultaneous nondestructive analysis of plutonium and americium in process solutions that have a wide range of concentrations and americium/plutonium ratios and for routine operation by process technicians who lack instrumentation background. The SAI, based on transmission-corrected, high-resolution gamma-ray spectroscopy, has two measurement stations attached to a single multichannel analyzer/computer system. To ensure the quality of assay results, the SAI has an internal measurement control program, which requires daily and weekly check runs and monitors key aspects of all assay runs. For a 25-ml sample, the assay precision is 5 g/l within a 2000-s count time

  8. Transferability study of CHO cell clustering assays for monitoring of pertussis toxin activity in acellular pertussis vaccines.

    Science.gov (United States)

    Isbrucker, R; Daas, A; Wagner, L; Costanzo, A

    2016-01-01

    Current regulations for acellular pertussis (aP) vaccines require that they are tested for the presence of residual or reversion-derived pertussis toxin (PTx) activity using the mouse histamine sensitisation test (HIST). Although a CHO cell clustering assay can be used by manufacturers to verify if sufficient inactivation of the substance has occurred in-process, this assay cannot be used at present for the final product due to the presence of aluminium adjuvants which interfere with mammalian cell cultures. Recently, 2 modified CHO cell clustering assays which accommodate for the adjuvant effects have been proposed as alternatives to the HIST. These modified assays eliminate the adjuvant-induced cytotoxicity either through dilution of the vaccine (called the Direct Method) or by introducing a porous barrier between the adjuvant and the cells (the Indirect Method). Transferability and suitability of these methods for testing of products present on the European market were investigated during a collaborative study organised by the European Directorate for the Quality of Medicines & HealthCare (EDQM). Thirteen laboratories participated in this study which included 4 aP-containing vaccines spiked by addition of PTx. This study also assessed the transferability of a standardised CHO cell clustering assay protocol for use with non-adjuvanted PTx preparations. Results showed that the majority of laboratories were able to detect the PTx spike in all 4 vaccines at concentrations of 4 IU/mL or lower using the Indirect Method. This sensitivity is in the range of the theoretical sensitivity of the HIST. The Direct Method however did not show the expected results and would need additional development work.

  9. Loop-mediated isothermal amplification assay for rapid detection of Streptococcus agalactiae (group B streptococcus) in vaginal swabs - a proof of concept study.

    Science.gov (United States)

    McKenna, James Patrick; Cox, Ciara; Fairley, Derek John; Burke, Rachael; Shields, Michael D; Watt, Alison; Coyle, Peter Valentine

    2017-03-01

    Neonatal sepsis caused by Streptococcus agalactiae [group B streptococcus (GBS)] is a life-threatening condition, which is preventable if colonized mothers are identified and given antibiotic prophylaxis during labour. Conventional culture is time consuming and unreliable, and many available non-culture diagnostics are too complex to implement routinely at point of care. Loop-mediated isothermal amplification (LAMP) is a method that, enables the rapid and specific detection of target nucleic acid sequences in clinical materials without the requirement for extensive sample preparation. A prototype LAMP assay targeting GBS sip gene is described. The assay was 100 % specific for GBS, with a limit of detection of 14 genome copies per reaction. The clinical utility of the LAMP assay for rapid direct molecular detection of GBS was determined by testing a total of 157 vaginal swabs with minimal sample processing using a rapid lysis solution. Compared to a reference quantitative real-time PCR assay, the direct LAMP protocol had a sensitivity and specificity of 95.4 and 100 %, respectively, with positive and negative predictive values of 100 and 98.3 %, respectively. Positive and negative likelihood ratios were infinity and 0.05, respectively. The direct LAMP method required a mean time of 45 min from the receipt of a swab to generation of a confirmed result, compared to 2 h 30 min for the reference quantitative real-time PCR test. The direct LAMP protocol described is easy to perform, facilitating rapid and accurate detection of GBS in vaginal swabs. This test has a potential for use at point of care.

  10. Making transuranic assay measurements using modern controllers

    International Nuclear Information System (INIS)

    Kuckertz, T.H.; Caldwell, J.T.; Medvick, P.A.; Kunz, W.E.; Hastings, R.D.

    1987-01-01

    This paper describes methodology and computer-controlled instrumentation developed at the Los Alamos National Laboratory that accurately performs nondestructive assays of large containers bearing transuranic wastes and nonradioactive matrix materials. These assay systems can measure fissile isotopes with 1-mg sensitivity and spontaneous neutron-emitting isotopes at a 10-mg sensitivity. The assays are performed by neutron interrogation, detection, and counting in a custom assay chamber. An International Business Machines Personal Computer (IBM-PC) is used to control the CAMAC-based instrumentation system that acquires the assay data. 6 refs., 7 figs

  11. Assessing the toxicity of sediments using the medaka embryo-larval assay and 2 other bioassays.

    Science.gov (United States)

    Barhoumi, Badreddine; Clérandeau, Christelle; Landi, Laure; Pichon, Anaïk; Le Bihanic, Florane; Poirier, Dominique; Anschutz, Pierre; Budzinski, Hélène; Driss, Mohamed Ridha; Cachot, Jérôme

    2016-09-01

    Sediments are sinks for aquatic pollutants, and analyzing toxicity in such complex matrices is still challenging. To evaluate the toxicity of bioavailable pollutants accumulated in sediments from the Bizerte lagoon (Tunisia), a novel assay, the medaka embryo-larval assay by sediment contact, was applied. Japanese medaka (Oryzias latipes) embryos were incubated in direct contact with sediment samples up to hatching. Lethal and sublethal adverse effects were recorded in embryos and larvae up to 20 d postfertilization. Results from medaka embryo-larval assay were compared with cytotoxicity (Microtox®), genotoxicity (SOS chromotest), and pollutant content of sediments. The results highlight differences in the contamination profile and toxicity pattern between the different studied sediments. A significant correlation was shown between medaka embryo-larval assay by sediment contact and SOS chromotest responses and concentrations of most organic pollutants studied. No correlation was shown between pollutant levels and Microtox. According to the number of sediment samples detected as toxic, medaka embryo-larval assay by sediment contact was more sensitive than Microtox, which in turn was more sensitive than the SOS chromotest; and medaka embryo-larval assay by sediment contact allowed sediment toxicity assessment of moderately polluted sediments without pollutant extraction and using an ecologically realistic exposure scenario. Although medaka embryo-larval assay by sediment contact should be tested on a larger sample set, the results show that it is sensitive and convenient enough to monitor the toxicity of natural sediments. Environ Toxicol Chem 2016;35:2270-2280. © 2016 SETAC. © 2016 SETAC.

  12. Scintillation proximity assay

    International Nuclear Information System (INIS)

    Hart, H.

    1980-01-01

    In a method of immunological assay two different classes of particles which interact at short distances to produce characteristic detectable signals are employed in a modification of the usual latex fixation test. In one embodiment an aqueous suspension of antigen coated tritiated latex particles (LH) and antigen coated polystyrene scintillant particles (L*) is employed to assay antibody in the aqueous medium. The amount of (LH) (L*) dimer formation and higher order aggregation induced and therefore the concentration of antibody (or antigen) present which caused the aggregation can be determined by using standard liquid scintillation counting equipment. (author)

  13. Multiplex PCR assay for the detection of five meat species forbidden in Islamic foods.

    Science.gov (United States)

    Ali, Md Eaqub; Razzak, Md Abdur; Hamid, Sharifah Bee Abd; Rahman, Md Mahfujur; Amin, Md Al; Rashid, Nur Raifana Abd; Asing

    2015-06-15

    Food falsification has direct impact on public health, religious faith, fair-trades and wildlife. For the first time, here we described a multiplex polymerase chain reaction assay for the accurate identification of five meat species forbidden in Islamic foods in a single assay platform. Five pairs of species-specific primers were designed targeting mitochondrial ND5, ATPase 6, and cytochrome b genes to amplify 172, 163, 141, 129 and 108 bp DNA fragments from cat, dog, pig, monkey and rat meats, respectively. All PCR products were identified in gel-images and electrochromatograms obtained from Experion Bioanalyzer. Species-specificity checking against 15 important meat and fish and 5 plant species detected no cross-species amplification. Screening of target species in model and commercial meatballs reflected its application to detect target species in process foods. The assay was tested to detect 0.01-0.02 ng DNA under raw states and 1% suspected meats in meatball formulation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Application of firefly luciferase assay for adenosine triphosphate (ATP) to antimicrobial drug sensitivity testing

    Science.gov (United States)

    Picciolo, G. L.; Tuttle, S. A.; Schrock, C. G.; Deming, J. W.; Barza, M. J.; Wienstein, L.; Chappelle, E. W.

    1977-01-01

    The development of a rapid method for determining microbial susceptibilities to antibiotics using the firefly luciferase assay for adenosine triphosphate (ATP) is documented. The reduction of bacterial ATP by an antimicrobial agent was determined to be a valid measure of drug effect in most cases. The effect of 12 antibiotics on 8 different bacterial species gave a 94 percent correlation with the standard Kirby-Buer-Agar disc diffusion method. A 93 percent correlation was obtained when the ATP assay method was applied directly to 50 urine specimens from patients with urinary tract infections. Urine samples were centrifuged first to that bacterial pellets could be suspended in broth. No primary isolation or subculturing was required. Mixed cultures in which one species was predominant gave accurate results for the most abundant organism. Since the method is based on an increase in bacterial ATP with time, the presence of leukocytes did not interfere with the interpretation of results. Both the incubation procedure and the ATP assays are compatible with automation.

  15. A molecular-beacon-based asymmetric PCR assay for easy visualization of amplicons in the diagnosis of trichomoniasis.

    Science.gov (United States)

    Sonkar, Subash C; Sachdev, Divya; Mishra, Prashant K; Kumar, Anita; Mittal, Pratima; Saluja, Daman

    2016-12-15

    The currently available nucleic acid amplification tests (NAATs) for trichomoniasis are accurate, quick and confirmative with superior sensitivity than traditional culture-based microbiology assays. However, these assays are associated with problems of carry over contamination, false positive results, requirement of technical expertise for performance and detection of end product. Hence, a diagnostic assay with easy visualization of the amplified product will be profitable. An in-house, rapid, sensitive, specific molecular-beacon-based PCR assay, using primers against pfoB gene of Trichomonas vaginalis, was developed and evaluated using dry ectocervical swabs (n=392) from symptomatic females with vaginal discharge. Total DNA was isolated and used as template for the PCR assays. The performance and reproducibility of PCR assay was evaluated by composite reference standard (CRS). For easy visualization of the amplified product, molecular-beacon was designed and amplicons were visualized directly using fluorescent handheld dark reader or by Micro-Plate Reader. Molecular-beacons are single-stranded hairpin shaped nucleic acid probes composed of a stem, with fluorophore/quencher pair and a loop region complementary to the desired DNA. The beacon-based PCR assay designed in the present study is highly specific as confirmed by competition experiments and extremely sensitive with detection limit of 20fg of genomic DNA (3-4 pathogens). The minimum infrastructure requirement and ease to perform the assay makes this method highly useful for resource poor countries for better disease management. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Bench-top validation testing of selected immunological and molecular Renibacterium salmoninarum diagnostic assays by comparison with quantitative bacteriological culture

    Science.gov (United States)

    Elliott, D.G.; Applegate, L.J.; Murray, A.L.; Purcell, M.K.; McKibben, C.L.

    2013-01-01

    No gold standard assay exhibiting error-free classification of results has been identified for detection of Renibacterium salmoninarum, the causative agent of salmonid bacterial kidney disease. Validation of diagnostic assays for R. salmoninarum has been hindered by its unique characteristics and biology, and difficulties in locating suitable populations of reference test animals. Infection status of fish in test populations is often unknown, and it is commonly assumed that the assay yielding the most positive results has the highest diagnostic accuracy, without consideration of misclassification of results. In this research, quantification of R. salmoninarum in samples by bacteriological culture provided a standardized measure of viable bacteria to evaluate analytical performance characteristics (sensitivity, specificity and repeatability) of non-culture assays in three matrices (phosphate-buffered saline, ovarian fluid and kidney tissue). Non-culture assays included polyclonal enzyme-linked immunosorbent assay (ELISA), direct smear fluorescent antibody technique (FAT), membrane-filtration FAT, nested polymerase chain reaction (nested PCR) and three real-time quantitative PCR assays. Injection challenge of specific pathogen-free Chinook salmon, Oncorhynchus tshawytscha (Walbaum), with R. salmoninarum was used to estimate diagnostic sensitivity and specificity. Results did not identify a single assay demonstrating the highest analytical and diagnostic performance characteristics, but revealed strengths and weaknesses of each test.

  17. Assessing sediment contamination using six toxicity assays

    Directory of Open Access Journals (Sweden)

    Allen G. BURTON Jr.

    2001-08-01

    Full Text Available An evaluation of sediment toxicity at Lake Orta, Italy was conducted to compare a toxicity test battery of 6 assays and to evaluate the extent of sediment contamination at various sediment depths. Lake Orta received excessive loadings of copper and ammonia during the 1900’s until a large remediation effort was conducted in 1989-90 using lime addition. Since that time, the lake has shown signs of a steady recovery of biological communities. The study results showed acute toxicity still exists in sediments at a depth of 5 cm and greater. Assays that detected the highest levels of toxicity were two whole sediment exposures (7 d using Hyalella azteca and Ceriodaphnia dubia. The MicrotoxR assay using pore water was the third most sensitive assay. The Thamnotox, Rototox, Microtox solid phase, and Seed Germination-Root Elongation (pore and solid phase assays showed occasional to no toxicity. Based on similarity of responses and assay sensitivity, the two most useful assays were the C. dubia (or H. azteca and Microtox pore water. These assays were effective at describing sediment toxicity in a weight-of-evidence approach.

  18. Building predictive in vitro pulmonary toxicity assays using high-throughput imaging and artificial intelligence.

    Science.gov (United States)

    Lee, Jia-Ying Joey; Miller, James Alastair; Basu, Sreetama; Kee, Ting-Zhen Vanessa; Loo, Lit-Hsin

    2018-06-01

    Human lungs are susceptible to the toxicity induced by soluble xenobiotics. However, the direct cellular effects of many pulmonotoxic chemicals are not always clear, and thus, a general in vitro assay for testing pulmonotoxicity applicable to a wide variety of chemicals is not currently available. Here, we report a study that uses high-throughput imaging and artificial intelligence to build an in vitro pulmonotoxicity assay by automatically comparing and selecting human lung-cell lines and their associated quantitative phenotypic features most predictive of in vivo pulmonotoxicity. This approach is called "High-throughput In vitro Phenotypic Profiling for Toxicity Prediction" (HIPPTox). We found that the resulting assay based on two phenotypic features of a human bronchial epithelial cell line, BEAS-2B, can accurately classify 33 reference chemicals with human pulmonotoxicity information (88.8% balance accuracy, 84.6% sensitivity, and 93.0% specificity). In comparison, the predictivity of a standard cell-viability assay on the same set of chemicals is much lower (77.1% balanced accuracy, 84.6% sensitivity, and 69.5% specificity). We also used the assay to evaluate 17 additional test chemicals with unknown/unclear human pulmonotoxicity, and experimentally confirmed that many of the pulmonotoxic reference and predicted-positive test chemicals induce DNA strand breaks and/or activation of the DNA-damage response (DDR) pathway. Therefore, HIPPTox helps us to uncover these common modes-of-action of pulmonotoxic chemicals. HIPPTox may also be applied to other cell types or models, and accelerate the development of predictive in vitro assays for other cell-type- or organ-specific toxicities.

  19. Design of LSDS for Isotopic Fissile Assay in Spent Fuel

    International Nuclear Information System (INIS)

    Lee, Yongdeok; Park, Changje; Kim, Hodong; Song, Kee Chan

    2013-01-01

    A future nuclear energy system is being developed at Korea Atomic Energy Research Institute (KAERI), the system involves a Sodium Fast Reactor (SFR) linked with the pyro-process. The pyro-process produces a source material to fabricate a SFR fuel rod. Therefore, an isotopic fissile content assay is very important for fuel rod safety and SFR economics. A new technology for an analysis of isotopic fissile content has been proposed using a lead slowing down spectrometer (LSDS). The new technology has several features for a fissile analysis from spent fuel: direct isotopic fissile assay, no background interference, and no requirement from burnup history information. Several calculations were done on the designed spectrometer geometry: detection sensitivity, neutron energy spectrum analysis, neutron fission characteristics, self shielding analysis, and neutron production mechanism. The spectrum was well organized even at low neutron energy and the threshold fission chamber was a proper choice to get prompt fast fission neutrons. The characteristic fission signature was obtained in slowing down neutron energy from each fissile isotope. Another application of LSDS is for an optimum design of the spent fuel storage, maximization of the burnup credit and provision of the burnup code correction factor. Additionally, an isotopic fissile content assay will contribute to an increase in transparency and credibility for the utilization of spent fuel nuclear material, as internationally demanded

  20. The review of identification and assay methods of β-blockers

    Directory of Open Access Journals (Sweden)

    Ольга Олександрівна Віслоус

    2015-10-01

    Full Text Available Every year the number of β-blockers on the pharmaceutical market is increasing, requiring systematization of their standardization methods.Aim of research. The aim of our research is to study literature data about identification and assay methods of β-blockers with different direction of action – selective (praktolol, metoprolol, atenolol, acebutolol, betaxolol, bevantolol, bisoprolol, celiprolol, esmolol, epanolol, esatenolol, nebivolol, Talinolol, non-selective (alprenolol, Oxprenololum, pindolol, propranolol, timolol, sotalol, nadolol, mepindolol, karteol, tertatolol, bopindolol, bupranolol, penbutolol, kloranolol and combined (labetalol, carvedilol.Methods. The analytical review of literature sources about β-blockers analysis by physical, chemical, and physicochemical methods.Results. After literature sources’ analyzing it was found that physical and physicochemical constants are basically used for β-blockers pharmacopoeial analysis; both physicochemical values and chemical reactions are used in forensic analysis, resulting in the article.It was founded that titration methods, mostly acid-base titration method, are used for β-blockers assay in the analysis of substances. For β-blockers detection in biological fluids and dosage forms, active pharmaceutical ingredients and metabolites mixture separation one should prefer physicochemical methods, such as gas chromatography and liquid chromatography, absorption UV-Visible spectroscopy, fluorometry, etc.Conclusion. The results have shown can be used for the further search of the identification and assay optimal methods of β-blockers both pure and mixed with other active substances and excipients

  1. DESIGN OF LSDS FOR ISOTOPIC FISSILE ASSAY IN SPENT FUEL

    Directory of Open Access Journals (Sweden)

    YONGDEOK LEE

    2013-12-01

    Full Text Available A future nuclear energy system is being developed at Korea Atomic Energy Research Institute (KAERI, the system involves a Sodium Fast Reactor (SFR linked with the pyro-process. The pyro-process produces a source material to fabricate a SFR fuel rod. Therefore, an isotopic fissile content assay is very important for fuel rod safety and SFR economics. A new technology for an analysis of isotopic fissile content has been proposed using a lead slowing down spectrometer (LSDS. The new technology has several features for a fissile analysis from spent fuel: direct isotopic fissile assay, no background interference, and no requirement from burnup history information. Several calculations were done on the designed spectrometer geometry: detection sensitivity, neutron energy spectrum analysis, neutron fission characteristics, self shielding analysis, and neutron production mechanism. The spectrum was well organized even at low neutron energy and the threshold fission chamber was a proper choice to get prompt fast fission neutrons. The characteristic fission signature was obtained in slowing down neutron energy from each fissile isotope. Another application of LSDS is for an optimum design of the spent fuel storage, maximization of the burnup credit and provision of the burnup code correction factor. Additionally, an isotopic fissile content assay will contribute to an increase in transparency and credibility for the utilization of spent fuel nuclear material, as internationally demanded.

  2. High local carcinogenic activity of 1,3-dimethyl-3-phenyl-1-nitrosourea and its inactivation by intravenous application in rats: comparison of in vivo findings with the in vitro direct and a combined in vivo/in vitro sister chromatid exchange assay in V79-E cells.

    Science.gov (United States)

    Thust, R; Martin, J; Mendel, J; Schreiber, D

    1987-02-01

    1,3-Dimethyl-3-phenyl-1-nitrosourea (DMPNU) is a very potent local carcinogen in rats and induces a 100% frequency of forestomach carcinomas when applied i.g. in two different dosages (10 applications of 0.3 or 0.03 mmol/kg body wt, respectively, at 14-day intervals), but it is inactive upon i.v. administration (10 applications of 0.03 mmol/kg body wt at 14-day intervals). By means of the direct sister chromatid exchange (SCE) assay in V79-E cells in the presence of rat blood, serum or plasma, respectively, as well as by a 'host-mediated' SCE assay (in which the agent was given i.v. to rats, and blood taken from the animal was checked for the recovery of genotoxic activity in cell cultures), we tried to elucidate the unexpected lack of carcinogenic activity of i.v. DMPNU. The direct SCE assay revealed a drastic reduction of DMPNU genotoxicity by rat blood, serum or plasma, respectively, which is abolished by the esterase inhibitor diisopropylfluorophosphate. In the 'host-mediated' SCE assay a genotoxic activity of DMPNU was only recoverable after a very high i.v. dose and when the blood added to the cell cultures had been taken from the rat heart within 1 min after DMPNU administration in vivo. 1-Methyl-1-nitrosourea (MNU) and 1-methyl-3-phenyl-1-nitrosourea (MPNU) were used as positive controls in these experiments and also gave a lower response than theoretically expected, but the relative loss of activity with the latter compounds was much lower than with DMPNU. It is assumed that an esterase in rat blood effectively decomposes this trisubstituted nitrosourea. Problems of the novel 'host-mediated' SCE assay are discussed.

  3. Site-directed mutagenesis in Petunia × hybrida protoplast system using direct delivery of purified recombinant Cas9 ribonucleoproteins.

    Science.gov (United States)

    Subburaj, Saminathan; Chung, Sung Jin; Lee, Choongil; Ryu, Seuk-Min; Kim, Duk Hyoung; Kim, Jin-Soo; Bae, Sangsu; Lee, Geung-Joo

    2016-07-01

    Site-directed mutagenesis of nitrate reductase genes using direct delivery of purified Cas9 protein preassembled with guide RNA produces mutations efficiently in Petunia × hybrida protoplast system. The clustered, regularly interspaced, short palindromic repeat (CRISPR)-CRISPR associated endonuclease 9 (CRISPR/Cas9) system has been recently announced as a powerful molecular breeding tool for site-directed mutagenesis in higher plants. Here, we report a site-directed mutagenesis method targeting Petunia nitrate reductase (NR) gene locus. This method could create mutations efficiently using direct delivery of purified Cas9 protein and single guide RNA (sgRNA) into protoplast cells. After transient introduction of RNA-guided endonuclease (RGEN) ribonucleoproteins (RNPs) with different sgRNAs targeting NR genes, mutagenesis at the targeted loci was detected by T7E1 assay and confirmed by targeted deep sequencing. T7E1 assay showed that RGEN RNPs induced site-specific mutations at frequencies ranging from 2.4 to 21 % at four different sites (NR1, 2, 4 and 6) in the PhNR gene locus with average mutation efficiency of 14.9 ± 2.2 %. Targeted deep DNA sequencing revealed mutation rates of 5.3-17.8 % with average mutation rate of 11.5 ± 2 % at the same NR gene target sites in DNA fragments of analyzed protoplast transfectants. Further analysis from targeted deep sequencing showed that the average ratio of deletion to insertion produced collectively by the four NR-RGEN target sites (NR1, 2, 4, and 6) was about 63:37. Our results demonstrated that direct delivery of RGEN RNPs into protoplast cells of Petunia can be exploited as an efficient tool for site-directed mutagenesis of genes or genome editing in plant systems.

  4. Combined high-performance liquid chromatography/32P-postlabeling assay of N7-methyldeoxyguanosine

    International Nuclear Information System (INIS)

    Shields, P.G.; Povey, A.C.; Wilson, V.L.; Weston, A.; Harris, C.C.

    1990-01-01

    A highly sensitive and specific assay for the detection of N7-methyl-2'-deoxyguanosine (N7methyldG) has been developed by combining high-performance liquid chromatography, 32 P-postlabeling, and nucleotide chromatography. Separation of normal nucleotides and adducts by high-performance liquid chromatography and then combining a portion of 2'-deoxyguanosine to the N7methyldG allows for quantitation using an internal standard. The directly determined molar ratio is not subject to errors in digestion, variable ATP-specific activity, or assumptions in relative adduct-labeling efficiency. The detection limit was one N7methyldG adduct in 10(7) unmodified 2'-deoxyguanosine bases. N7methyldG adducts have been detected in 5 human lung samples in which O6-methyl-2'-deoxyguanosine adducts had been previously determined. The mean ratio of N7methyldG to O6-methyl-2'-deoxyguanosine was determined to be approximately 10. The current assay complements the high-performance liquid chromatography/ 32 P-postlabeling assay for O6-methyl-2'-deoxyguanosine and increases the detection sensitivity of DNA methylated by exogenous alkylating agents

  5. A Soluble Fluorescent Binding Assay Reveals PIP2 Antagonism of TREK-1 Channels

    Directory of Open Access Journals (Sweden)

    Cerrone Cabanos

    2017-08-01

    Full Text Available Lipid regulation of ion channels by low-abundance signaling lipids phosphatidylinositol 4,5-bisphosphate (PIP2 and phosphatidic acid (PA has emerged as a central cellular mechanism for controlling ion channels and the excitability of nerves. A lack of robust assays suitable for facile detection of a lipid bound to a channel has hampered the probing of the lipid binding sites and measuring the pharmacology of putative lipid agonists for ion channels. Here, we show a fluorescent PIP2 competition assay for detergent-purified potassium channels, including TWIK-1-related K+-channel (TREK-1. Anionic lipids PA and phosphatidylglycerol (PG bind dose dependently (9.1 and 96 μM, respectively and agonize the channel. Our assay shows PIP2 binds with high affinity (0.87 μM but surprisingly can directly antagonize TREK-1 in liposomes. We propose a model for TREK-1 lipid regulation where PIP2 can compete with PA and PG agonism based on the affinity of the lipid for a site within the channel.

  6. Evaluating Factor XIII Specificity for Glutamine-Containing Substrates Using a MALDI-TOF Mass Spectrometry Assay

    Science.gov (United States)

    Doiphode, Prakash G.; Malovichko, Marina V.; Mouapi, Kelly Njine; Maurer, Muriel C.

    2014-01-01

    Activated Factor XIII (FXIIIa) catalyzes the formation of γ-glutamyl-ε-lysyl cross-links within the fibrin blood clot network. Although several cross-linking targets have been identified, the characteristic features that define FXIIIa substrate specificity are not well understood. To learn more about how FXIIIa selects its targets, a matrix-assisted laser desorption ionization – time of flight mass spectrometry (MALDI-TOF MS) based assay was developed that could directly follow the consumption of a glutamine-containing substrate and the formation of a cross-linked product with glycine ethylester. This FXIIIa kinetics assay is no longer reliant on a secondary coupled reaction, on substrate labeling, or on detecting the final deacylation portion of the transglutaminase reaction. With the MALDI-TOF MS assay, glutamine-containing peptides derived from α2-antiplasmin, S. Aureus fibronectin binding protein A, and thrombin activatable fibrinolysis inhibitor were examined directly. Results suggest that the FXIIIa active site surface responds to changes in substrate residues following the reactive glutamine. The P-1 substrate position is sensitive to charge character and the P-2 and P-3 to the broad FXIIIa substrate specificity pockets. The more distant P-8 to P-11 region serves as a secondary substrate anchoring point. New knowledge on FXIIIa specificity may be used to design better substrates or inhibitors of this transglutaminase. PMID:24751466

  7. Rapid high-throughput assay to assess scavenging capacity index using DPPH.

    Science.gov (United States)

    Abderrahim, Fatima; Arribas, Silvia M; Gonzalez, M Carmen; Condezo-Hoyos, Luis

    2013-11-15

    A new microplate-adapted DPPH rapid assay was developed to assess the antioxidant capacity of pure compounds and foods. The assay was carried out in buffered medium (methanol: 10mmol/l Tris buffer pH 7.5, 1:1 v/v) and reaction was completed at 10min. The scavenging capacity index (SCI), a theoretical antioxidant parameter directly related to the antioxidant capacity of samples, was calculated. SCI for pure compounds: gallic acid (6.76±0.08), quercetin (7.89±0.24), catechin (6.05±0.23), trolox (2.32±0.03), ascorbic acid (2.52±0.15) and gluthatione (1.08±0.08) and foods (μmol DPPH scavenged/100ml): tropical juice (655.62±12.18), mediterraneo juice (702.87±11.13), apple juice (212.52±17.22), pomegranate juice (319.83±9.45), red grape nectar (1093.05±18.69), Don Simon orange juice (632.94±17.22) and date syrup (15992.34±250.7) were comparable to those in previous reports using the classic DPPH assay. The relative standard deviation (RSD) for the SCI on the same and different days was less than 8.12% in all cases. Copyright © 2013 Elsevier Ltd. All rights reserved.

  8. 75 FR 59611 - Microbiology Devices; Reclassification of Herpes Simplex Virus Types 1 and 2 Serological Assays...

    Science.gov (United States)

    2010-09-28

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 866 [Docket No. FDA-2009-N-0344] Microbiology Devices; Reclassification of Herpes Simplex Virus Types 1 and 2 Serological Assays; Confirmation of Effective Date AGENCY: Food and Drug Administration, HHS. ACTION: Direct...

  9. Changes and significance of plasma neuropeptide Y in patients with unstable angina pectoris

    International Nuclear Information System (INIS)

    Wang Xiaozhou; Yang Yongqing

    2001-01-01

    Objective: To observe changes of plasma neuropeptide Y(NPY) in patients with unstable angina pectoris (UaP), select patients with stable angina pectoris (SAP) and normal subjects as the controls, and recognize their significance. Methods: Immunoradiometric assay was used to measure the plasma NPY levels in 15 UAP patients, 20 SAP patients and 20 normal subjects: Results: It was found that the plasma NPY levels in patients with UAP, SAP and normal subjects were 202.12 +- 35.34, 164.45 +- 24.27 and 156.35 +- 21.84 pg/ml. The NPY levels in UAP patients were significantly higher than that in the others, but down to 159.66 +- 18.75 pg/ml after treatment for 2 weeks. There was a significant difference between pretreatment and post-treatment (P < 0.05). Conclusion: The plasma NPY levels of UAP patients increases significantly during fit. NPY takes part in the process of AP

  10. Radioimmunoassay of class-specific antibodies (RIACA): chicken antibodies to DNP

    International Nuclear Information System (INIS)

    Viljanen, M.K.; Granfors, K.; Toivanen, P.

    1977-01-01

    A radioimmunological method for the quantitation of class-specific antibodies has been developed. The method allows the quantitation of nanogram per ml concentrations of IgG and IgM-anti-DNP antibodies without any physical or chemical pretreatment of the sample. DNP was coupled covalently to a cyanogen bromide activated paper disk with the augmentation of lysine molecule. Anti-DNP antibodies were allowed to react with the coupled DNP and then quantitated by their capacity to bind 125 I-labelled anti-chicken-μ or anti-chicken-γ. The inter-assay variation coefficients ranged from 8.1 to 14.7% and the mean standard deviations of duplicate determinations were about 11%. The combination of this method with the exact immunoradiometric quantitation of the total serum IgM and IgG, and with an immunoabsorption technique, makes it possible to quantitate class-specific antibodies on weight units

  11. Iron, folacin, vitamin B12 and zinc status and immune response in the elderly

    International Nuclear Information System (INIS)

    Henry-Christian, J.R.; Johnson, A.A.; Walters, C.S.; Greene, E.J.; Lindsey, A.A.

    1986-01-01

    The relationships of iron, folacin, vitamin B 12 and zinc status to cell-mediated immune response were investigated among 125 healthy, elderly persons (60-87 years of age). Plasma ferritin, plasma and red cell folate, and plasma vitamin B 12 levels were assayed immuno-radiometrically. Plasma and hair zinc levels were determined by atomic absorption spectroscopy. Immune response was determined by transformation of peripheral blood lymphocytes after stimulation with phytohemagglutinin (PHA) and concanavalin A (con A), and in mixed lymphocyte reaction. Deficiencies of iron, folacin vitamin B 12 and zinc were each associated (independently) with significantly lower lymphocyte responses to PHA and con A, and mixed lymphocyte reaction (P 12 or zinc. Further, they suggest that deficiencies of these nutrients may play a role in the depression of cell-mediated immunity with age, which in turn may lead to increased susceptibility to infectious diseases and cancer in the elderly

  12. Serum insulin-like growth factor 1(IGF-I) and prostatic cancer risk a retrospective study

    International Nuclear Information System (INIS)

    Li Liren; Liu Jiumin; Lu Bailing

    2001-01-01

    Objective: To investigate the relationship between serum IGF-I levels and prostatic cancer. Methods: Serum IGF-I levels were determined by immunoradiometric assay (IRMA) in 30 cases of prostatic cancer, 30 cases of benign prostatic hyperplasia (BPH) and 30 healthy subjects as controls. Results: The mean levels of serum IGF-I in prostatic cancer (148 +- 49.6 μg/L) were significantly higher than those in BPH (91.0 +- 32.8 μg/L) and healthy subjects (105 +- 25.6 μg/L) (P 0.05). The IGF-I levels were not relates to BHP, but increased values of IGF-I were associated with increased risk of prostatic cancer. The odds ratio was 11.23 for patients of prostatic cancer compared with healthy subjects, (95 percent confidence interval 3.09 - 40.7). Conclusion: This finding suggests that high IGF-I may be associated with increase risk of prostate cancer in human

  13. CYTOKINESIS-BLOCK MICRONUCLEUS ASSAY IN HUMAN GLIOMA CELLS EXPOSED TO RADIATION

    Directory of Open Access Journals (Sweden)

    Jerzy Slowinski

    2011-05-01

    Full Text Available Biological tests are efficient in reflecting the biological influences of several types of generally harmful exposures. The micronucleus assay is widely used in genotoxicity studies or studies on genomic damage in general. We present methodological aspects of cytokinesis-block micronucleus assay performed in human gliomas irradiated in vitro. Eight human glioblastoma cell lines obtained from DSMZ (Deutsche Sammlung von Mikroorganismen und Zellkulturen GmbH, Germany were gamma-irradiated (60Co over a dose range of 0-10 Gy. Cytokinesis-block micronucleus assay was performed to quantitate cytogenetic damage. The cells were fixed directly on dishes, stained with fluorochrome DAPI and evaluated under fluorescent and phase contrast microscope. The micronucleus frequency was expressed as a micronuclei (MN per binucleated cell (BNC ratio, calculated after scoring at least 100 BNC per dish. The frequency of spontaneous MN ranged from 0.17 to 0.613 (mean: 0.29 ± 0.14. After irradiation increase of MN frequency in the range of 0.312 - 2.241 (mean: 0.98 ± 0.68 was found at 10 Gy. Gliomas are extremely heterogenous in regard to cytogenetic effects of irradiation, as shown in this study by cytokinesis-block micronucleus assay. This test is easily performed on irradiated glioma cell lines and can assist in determining their radiosensitivity. However, in order to obtain reliable and reproducible results, precise criteria for MN scoring must be strictly followed. Simultaneous use of fluorescent and phase contrast equipment improves imaging of morphological details and can further optimize MN scoring.

  14. A multiwell format assay for heparanase.

    Science.gov (United States)

    Behzad, Farhad; Brenchley, Paul E C

    2003-09-15

    This assay employs a biotinylated heparan sulfate glycosaminoglycan (HSGAG) substrate that is covalently linked to the surface of 96-well immunoassay plates. The ratio of biotin:HSGAG and the coating concentration of substrate bound to the wells have been optimized and allow removal of biotin HSGAG within 60 min of incubation at 37 degrees C in assay buffer with a standard dilution of bacterial heparitinase or platelet heparanase. Loss of biotin signal from the well surface is detected on incubation with peroxidase-streptavidin followed by color development using 3,3',5,5'-tetramethylbenzidine as the peroxidase substrate. The new assay allows specific detection of heparanase activity in multiple samples in a total time of 3 h including a 1-h substrate digestion step and is a significant improvement with regard to sensitivity, specificity, and ease of handling of multiple samples compared to other described assays. Heparanase specifically degrades the biotinylated HSGAG substrate, when used with an optimized assay buffer. A range of enzymes including collagenase, trypsin, plasmin, pepsin, chondroitinases, hyaluronidase, and neuraminidase show no effect on the substrate under optimized assay conditions. The covalent linkage of the substrate to the well prevents leaching of substrate and allows preparation and long-term storage of substrate-coated plates. The assay can be used to detect heparanase levels in clinical samples and cell culture supernatants and is ideal as a screening method for antagonists of enzyme activity.

  15. A quantitative comet infection assay for influenza virus

    Science.gov (United States)

    Lindsay, Stephen M.; Timm, Andrea; Yin, John

    2011-01-01

    Summary The virus comet assay is a cell-based virulence assay used to evaluate an antiviral drug or antibody against a target virus. The comet assay differs from the plaque assay in allowing spontaneous flows in 6-well plates to spread virus. When implemented quantitatively the comet assay has been shown to have an order-of-magnitude greater sensitivity to antivirals than the plaque assay. In this study, a quantitative comet assay for influenza virus is demonstrated, and is shown to have a 13-fold increase in sensitivity to ribavirin. AX4 cells (MDCK cells with increased surface concentration of α2–6 sialic acid, the influenza virus receptor) have reduced the comet size variability relative to MDCK cells, making them a better host cell for use in this assay. Because of enhanced antiviral sensitivity in flow-based assays, less drug is required, which could lead to lower reagent costs, reduced cytotoxicity, and fewer false-negative drug screen results. The comet assay also serves as a readout of flow conditions in the well. Observations from comets formed at varying humidity levels indicate a role for evaporation in the mechanism of spontaneous fluid flow in wells. PMID:22155578

  16. Assay development status report for total cyanide

    International Nuclear Information System (INIS)

    Simpson, B.C.; Jones, T.E.; Pool, K.H.

    1993-02-01

    A validated cyanide assay that is applicable to a variety of tank waste matrices is necessary to resolve certain waste tank safety issues and for purposes of overall waste characterization. The target for this effort is an assay with an applicable range of greater than 1,000 ppM (0.10 wt%) total cyanide and a confidence level greater than 80%. Figure 1 illustrates the operating regime of the proposed cyanide assay method. The Assay Development Status Report for Total Cyanide will summarize the past experience with cyanide analyses on-tank waste matrices and will rate the status of the analytical methods used to assay total cyanide (CN - ion) in the tank waste matrices as acceptable or unacceptable. This paper will also briefly describe the current efforts for improving analytical resolution of the assays and the attempts at speciation

  17. Prospects for cellular mutational assays in human populations

    International Nuclear Information System (INIS)

    Mendelsohn, M.L.

    1984-01-01

    Practical, sensitive, and effective human cellular assays for detecting somatic and germinal mutations would have great value in environmental mutagenesis and carcinogenesis studies. Such assays would fill the void between human mutagenicity and the data that exist from short-term tests and from mutagenicity in other species. This paper discusses the following possible human cellular assays: (1) HPRT (hypoxanthine phosphoribosyltransferase) somatic cell mutation based on 6-thioguanine resistance; (2) hemoglobin somatic cell mutation assay; (3) glycophorin somatic cell mutation assay; and (4) LDH-X sperm cell mutation assay. 18 references

  18. Prospects for cellular mutational assays in human populations

    Energy Technology Data Exchange (ETDEWEB)

    Mendelsohn, M.L.

    1984-06-29

    Practical, sensitive, and effective human cellular assays for detecting somatic and germinal mutations would have great value in environmental mutagenesis and carcinogenesis studies. Such assays would fill the void between human mutagenicity and the data that exist from short-term tests and from mutagenicity in other species. This paper discusses the following possible human cellular assays: (1) HPRT (hypoxanthine phosphoribosyltransferase) somatic cell mutation based on 6-thioguanine resistance; (2) hemoglobin somatic cell mutation assay; (3) glycophorin somatic cell mutation assay; and (4) LDH-X sperm cell mutation assay. 18 references.

  19. A radiochemical assay for biotin in biological materials

    International Nuclear Information System (INIS)

    Hood, R.L.

    1975-01-01

    A radiochemical assay for biotin is described. The assay was sensitive to one nanogram and simple enough for routine biotin analyses. The assay yielded results which were comparable to those obtained from a microbiological assay using Lactobacillus plantarum. (author)

  20. Oxygen consumption in Plasmodium berghei-infected murine red cells: a direct spectrophotometric assay in intact erythrocytes.

    Science.gov (United States)

    Deslauriers, R; Moffatt, D J; Smith, I C

    1986-05-29

    A spectrophotometric assay has been devised to measure oxygen consumption non-invasively in intact murine red cells parasitized by Plasmodium berghei. The method uses oxyhemoglobin in the erythrocytes both as a source of oxygen and as an indicator of oxygen consumption. Spectra of intact cells show broad peaks and sloping baselines due to light-scattering. In order to ascertain the number of varying components in the 370-450 nm range, the resolution of the spectra was enhanced using Fourier transforms of the frequency domain spectra. Calculation of oxygen consumption was carried out for two-component systems (oxyhemoglobin, deoxyhemoglobin) using absorbances at 415 and 431 nm. Samples prepared from highly parasitized mice (greater than 80% parasitemia, 5% hematocrit) showed oxygen consumption rates of (4-8) X 10(-8) microliter/cell per h. This rate was not attributable to the presence of white cells or reticulocytes. The rate of oxygen consumption in the erythrocytes is shown to be modulated by various agents: the respiratory inhibitors NaN3 and KCN (1 mM) reduced oxygen consumption 2-3-fold; salicylhydroxamic acid (2.5 mM) caused a 20% reduction in rate and 10 mM NaN3, completely blocked deoxygenation. Antimalarial drugs and metal-chelating agents were also tested. Chloroquine, EDTA and desferal (desferoxamine mesylate) did not decrease the deoxygenation rate of hemoglobin in parasitized cells. Quinacrine, quinine and primaquine reduced the rate of formation of deoxyhemoglobin but also produced substantial quantities of methemoglobin. The lipophilic chelator, 5-hydroxyquinoline, decreased the rate of deoxygenation one-third. The spectrophotometric assay provides a convenient means to monitor oxygen consumption in parasitized red cells, to test the effects of various agents thereon, and potentially to explore possible mechanisms for oxygen utilization.

  1. Relation between enzyme-linked immunosorbent assay and radioimmunoassay for detection of antibodies to the capsular polysaccharide of Haemophilus influenzae type b

    International Nuclear Information System (INIS)

    Kristensen, K.; Weis Bentzon, M.

    1992-01-01

    The measurement of antibodies to the capsular polysaccharide (PRP) of Haemophilus influenzae type b (Hib) is important because vaccines inducing such antibodies are now available. We developed and evaluated an enzyme-linked immunosorbent assay (ELISA) for detection of these antibodies based on direct coating of the plates with tyraminated PRP. The assay fulfilled the requirements for parallel line assays; it was sensitive, specific, and reproducible with a coefficient of variation between days of 19%. Results from the ELISA were compared with results from radioimmunoassay and a correlation coefficient of 0.93 was found. Results obtained by the two methods were proportional and the relation was indepenedent of the antibody level. The relation between them was also unaffected by the contribution of different antibody isotypes, indicating that these were measured to the same extent by both methods. ELISA employing direct coating of the plates with tyraminated PRP represents a useful alternative for detection of antibodies when studying immunogenicity of Hib vaccines. (au)

  2. Development of loop-mediated isothermal amplification (LAMP assay for rapid and sensitive identification of ostrich meat.

    Directory of Open Access Journals (Sweden)

    Amir Abdulmawjood

    Full Text Available Animal species identification is one of the primary duties of official food control. Since ostrich meat is difficult to be differentiated macroscopically from beef, therefore new analytical methods are needed. To enforce labeling regulations for the authentication of ostrich meat, it might be of importance to develop and evaluate a rapid and reliable assay. In the present study, a loop-mediated isothermal amplification (LAMP assay based on the cytochrome b gene of the mitochondrial DNA of the species Struthio camelus was developed. The LAMP assay was used in combination with a real-time fluorometer. The developed system allowed the detection of 0.01% ostrich meat products. In parallel, a direct swab method without nucleic acid extraction using the HYPLEX LPTV buffer was also evaluated. This rapid processing method allowed detection of ostrich meat without major incubation steps. In summary, the LAMP assay had excellent sensitivity and specificity for detecting ostrich meat and could provide a sampling-to-result identification-time of 15 to 20 minutes.

  3. Linearization of the Bradford Protein Assay

    OpenAIRE

    Ernst, Orna; Zor, Tsaffrir

    2010-01-01

    Determination of microgram quantities of protein in the Bradford Coomassie brilliant blue assay is accomplished by measurement of absorbance at 590 nm. This most common assay enables rapid and simple protein quantification in cell lysates, cellular fractions, or recombinant protein samples, for the purpose of normalization of biochemical measurements. However, an intrinsic nonlinearity compromises the sensitivity and accuracy of this method. It is shown that under standard assay conditions, t...

  4. New automated pellet/powder assay system

    International Nuclear Information System (INIS)

    Olsen, R.N.

    1975-01-01

    This paper discusses an automated, high precision, pellet/ powder assay system. The system is an active assay system using a small isotopic neutron source and a coincidence detection system. The handling of the pellet powder samples has been automated and a programmable calculator has been integrated into the system to provide control and data analysis. The versatile system can assay uranium or plutonium in either active or passive modes

  5. Passive nondestructive assay of nuclear materials

    International Nuclear Information System (INIS)

    Reilly, D.; Ensslin, N.; Smith, H. Jr.; Kreiner, S.

    1991-03-01

    The term nondestructive assay (NDA) is applied to a series of measurement techniques for nuclear fuel materials. The techniques measure radiation induced or emitted spontaneously from the nuclear material; the measurements are nondestructive in that they do not alter the physical or chemical state of the nuclear material. NDA techniques are characterized as passive or active depending on whether they measure radiation from the spontaneous decay of the nuclear material or radiation induced by an external source. This book emphasizes passive NDA techniques, although certain active techniques like gamma-ray absorption densitometry and x-ray fluorescence are discussed here because of their intimate relation to passive assay techniques. The principal NDA techniques are classified as gamma-ray assay, neutron assay, and calorimetry. Gamma-ray assay techniques are treated in Chapters 1--10. Neutron assay techniques are the subject of Chapters 11--17. Chapters 11--13 cover the origin of neutrons, neutron interactions, and neutron detectors. Chapters 14--17 cover the theory and applications of total and coincidence neutron counting. Chapter 18 deals with the assay of irradiated nuclear fuel, which uses both gamma-ray and neutron assay techniques. Chapter 19 covers perimeter monitoring, which uses gamma-ray and neutron detectors of high sensitivity to check that no unauthorized nuclear material crosses a facility boundary. The subject of Chapter 20 is attribute and semiquantitative measurements. The goal of these measurements is a rapid verification of the contents of nuclear material containers to assist physical inventory verifications. Waste and holdup measurements are also treated in this chapter. Chapters 21 and 22 cover calorimetry theory and application, and Chapter 23 is a brief application guide to illustrate which techniques can be used to solve certain measurement problems

  6. First experiences with the AMERLEX-MAB FREE T4 assay

    International Nuclear Information System (INIS)

    Nijhof, W.A.; Penders, T.J.

    1989-01-01

    The new Amerlex-MAB FT 4 is a quick direct free T 4 assay with good reproducability. The correlation between the Amerlex-MAB FT 4 and the free T 4 of Byk is good. In the non-thyreoidal illness patient group no deviation for the values were found. Amerlex-MAB FT 4 is cheaper, because no total T4 has to be measured. More research has to be done for special patient sera. Disturbing influences as free fatty acids, heparin and auto-antibodies have to be checked. (R.B.). 3 refs.; 3 figs.; 4 tabs

  7. LSDS Development for Isotopic Fissile Content Assay

    International Nuclear Information System (INIS)

    Lee, Yong Deok; Park, Chang Je; Park, Geun Il; Lee, Jung Won; Song, Kee Chan

    2010-01-01

    Concerning the sustainable energy supply and green house effect, nuclear energy became the most feasible option to meet the energy demand in Korea. However, the production of the spent nuclear fuel is the inevitable situation. Since the first nuclear power plant started to produce the electricity in Korea, the accumulated amount of spent fuels exceeded 10k tomes recently. The accumulation of the spent fuels is the big issue in the society. Therefore, as an option which strengthens the nuclear proliferation resistance and reduces the amount of spent fuels, sodium fast reactor (SFR) program linked with pyro-processing is under development to re-use the PWR spent fuel and produce the energy. In the process, the produced metallic material involves uranium and TRU (transuranic; neptunium, plutonium, and americium). The uranium-TRU is used to fabricate SFR fuel. The burning the recycled fuel in the reactor is to solve the current spent fuel storage problem and to minimize the actinides accumulation having long half-life. Generally, the spent fuel from PWR has unburned ∼1 % U235, produced ∼0.5 % plutonium from decay chain, ∼3 % fission products, ∼ 0.1 % minor actinides (MA) and uranium remainder. About 1.5 % fissile materials still exist in the spent fuel. Therefore, spent fuel is not only waste but energy resource. The direct and isotopic fissile content assay is the crucial technology for the spent fuel reuse. Additionally, the fissile content analysis will contribute to the optimum storage design and safe spent fuel management. Several nondestructive technologies have been developed for the spent fuel assay; gamma ray measurement, passive and active neutron measurements. Spent fuel emits intense gamma rays and neutrons by (a, n) and spontaneous fission. This intense background has the limitation on the direct analysis of fissile materials. Recently, to analyze the individual fissile content, leadslowing down spectrometer (LSDS) has been being developed in Korea

  8. Rover waste assay system

    International Nuclear Information System (INIS)

    Akers, D.W.; Stoots, C.M.; Kraft, N.C.; Marts, D.J.

    1997-01-01

    The Rover Waste Assay System (RWAS) is a nondestructive assay system designed for the rapid assay of highly-enriched 235 U contaminated piping, tank sections, and debris from the Rover nuclear rocket fuel processing facility at the Idaho Chemical Processing Plant. A scanning system translates a NaI(Tl) detector/collimator system over the structural components where both relative and calibrated measurements for 137 Cs are made. Uranium-235 concentrations are in operation and is sufficiently automated that most functions are performed by the computer system. These functions include system calibration, problem identification, collimator control, data analysis, and reporting. Calibration of the system was done through a combination of measurements on calibration standards and benchmarked modeling. A description of the system is presented along with the methods and uncertainties associated with the calibration and analysis of the system for components from the Rover facility. 4 refs., 2 figs., 4 tabs

  9. Direct Molecular Detection and Genotyping of Borrelia burgdorferi from Whole Blood of Patients with Early Lyme Disease

    Science.gov (United States)

    Eshoo, Mark W.; Crowder, Christopher C.; Rebman, Alison W.; Rounds, Megan A.; Matthews, Heather E.; Picuri, John M.; Soloski, Mark J.; Ecker, David J.; Schutzer, Steven E.; Aucott, John N.

    2012-01-01

    Direct molecular tests in blood for early Lyme disease can be insensitive due to low amount of circulating Borrelia burgdorferi DNA. To address this challenge, we have developed a sensitive strategy to both detect and genotype B. burgdorferi directly from whole blood collected during the initial patient visit. This strategy improved sensitivity by employing 1.25 mL of whole blood, a novel pre-enrichment of the entire specimen extract for Borrelia DNA prior to a multi-locus PCR and electrospray ionization mass spectrometry detection assay. We evaluated the assay on blood collected at the initial presentation from 21 endemic area patients who had both physician-diagnosed erythema migrans (EM) and positive two-tiered serology either at the initial visit or at a follow-up visit after three weeks of antibiotic therapy. Results of this DNA analysis showed detection of B. burgdorferi in 13 of 21 patients (62%). In most cases the new assay also provided the B. burgdorferi genotype. The combined results of our direct detection assay with initial physician visit serology resulted in the detection of early Lyme disease in 19 of 21 (90%) of patients at the initial visit. In 5 of 21 cases we demonstrate the ability to detect B. burgdorferi in early Lyme disease directly from whole blood specimens prior to seroconversion. PMID:22590620

  10. Direct enzyme assay evidence confirms aldehyde reductase function of Ydr541cp and Ygl039wp from Saccharomyces cerevisiae.

    Science.gov (United States)

    Moon, Jaewoong; Liu, Z Lewis

    2015-04-01

    The aldehyde reductase gene ARI1 is a recently characterized member of an intermediate subfamily within the short-chain dehydrogenase/reductase (SDR) superfamily that clarified mechanisms of in situ detoxification of 2-furaldehyde and 5-hydroxymethyl-2-furaldehyde by Saccharomyces cerevisiae. Uncharacterized open reading frames (ORFs) are common among tolerant candidate genes identified for lignocellulose-to-advanced biofuels conversion. This study presents partially purified proteins of two ORFs, YDR541C and YGL039W, and direct enzyme assay evidence against aldehyde-inhibitory compounds commonly encountered during lignocellulosic biomass fermentation processes. Each of the partially purified proteins encoded by these ORFs showed a molecular mass of approximately 38 kDa, similar to Ari1p, a protein encoded by aldehyde reductase gene. Both proteins demonstrated strong aldehyde reduction activities toward 14 aldehyde substrates, with high levels of reduction activity for Ydr541cp toward both aromatic and aliphatic aldehydes. While Ydr541cp was observed to have a significantly higher specific enzyme activity at 20 U/mg using co-factor NADPH, Ygl039wp displayed a NADH preference at 25 U/mg in reduction of butylaldehyde. Amino acid sequence analysis identified a characteristic catalytic triad, Ser, Tyr and Lys; a conserved catalytic motif of Tyr-X-X-X-Lys; and a cofactor-binding sequence motif, Gly-X-X-Gly-X-X-Ala, near the N-terminus that are shared by Ydr541cp, Ygl039wp, Yol151wp/GRE2 and Ari1p. Findings of aldehyde reductase genes contribute to the yeast gene annotation and aids development of the next-generation biocatalyst for advanced biofuels production. Copyright © 2015 John Wiley & Sons, Ltd.

  11. Thermal precipitation fluorescence assay for protein stability screening.

    Science.gov (United States)

    Fan, Junping; Huang, Bo; Wang, Xianping; Zhang, Xuejun C

    2011-09-01

    A simple and reliable method of protein stability assessment is desirable for high throughput expression screening of recombinant proteins. Here we described an assay termed thermal precipitation fluorescence (TPF) which can be used to compare thermal stabilities of recombinant protein samples directly from cell lysate supernatants. In this assay, target membrane proteins are expressed as recombinant fusions with a green fluorescence protein tag and solubilized with detergent, and the fluorescence signals are used to report the quantity of the fusion proteins in the soluble fraction of the cell lysate. After applying a heat shock, insoluble protein aggregates are removed by centrifugation. Subsequently, the amount of remaining protein in the supernatant is quantified by in-gel fluorescence analysis and compared to samples without a heat shock treatment. Over 60 recombinant membrane proteins from Escherichia coli were subject to this screening in the presence and absence of a few commonly used detergents, and the results were analyzed. Because no sophisticated protein purification is required, this TPF technique is suitable to high throughput expression screening of recombinant membrane proteins as well as soluble ones and can be used to prioritize target proteins based on their thermal stabilities for subsequent large scale expression and structural studies. Copyright © 2011 Elsevier Inc. All rights reserved.

  12. A Comparison of Real-Time and Endpoint Cell Viability Assays for Improved Synthetic Lethal Drug Validation.

    Science.gov (United States)

    Single, Andrew; Beetham, Henry; Telford, Bryony J; Guilford, Parry; Chen, Augustine

    2015-12-01

    Cell viability assays fulfill a central role in drug discovery studies. It is therefore important to understand the advantages and disadvantages of the wide variety of available assay methodologies. In this study, we compared the performance of three endpoint assays (resazurin reduction, CellTiter-Glo, and nuclei enumeration) and two real-time systems (IncuCyte and xCELLigence). Of the endpoint approaches, both the resazurin reduction and CellTiter-Glo assays showed higher cell viabilities when compared directly to stained nuclei counts. The IncuCyte and xCELLigence real-time systems were comparable, and both were particularly effective at tracking the effects of drug treatment on cell proliferation at sub-confluent growth. However, the real-time systems failed to evaluate contrasting cell densities between drug-treated and control-treated cells at full growth confluency. Here, we showed that using real-time systems in combination with endpoint assays alleviates the disadvantages posed by each approach alone, providing a more effective means to evaluate drug toxicity in monolayer cell cultures. Such approaches were shown to be effective in elucidating the toxicity of synthetic lethal drugs in an isogenic pair of MCF10A breast cell lines. © 2015 Society for Laboratory Automation and Screening.

  13. Radioreceptor assay: theory and applications to pharmacology

    International Nuclear Information System (INIS)

    Perret, G.; Simon, P.

    1984-01-01

    The aim of the first part of this work is to present the theory of the radioreceptor assay and to compare it to the other techniques of radioanalysis (radioimmunoassay, competitive protein binding assays). The technology of the radioreceptor assay is then presented and its components (preparation of the receptors, radioligand, incubation medium) are described. The analytical characteristics of the radioreceptor assay (specificity, sensitivity, reproductibility, accuracy) and the pharmacological significance of the results are discussed. The second part is devoted to the description of the radioreceptor assays of some pharmacological classes (neuroleptics, tricyclic antidepressants, benzodiazepines, β-blockers, anticholinergic drugs) and to their use in therapeutic drug monitoring. In conclusion, by their nature, radioreceptor assays are highly sensitive, reliable, precise, accurate and simple to perform. Their chief disadvantage relates to specificity, since any substance having an appreciable affinity to the receptor site will displace the specifically bound radioligand. Paradoxically in some cases, this lack of specificity may be advantageous in that it allows for the detection of not only the apparent compound but of active metabolites and endogenous receptor agonists as well and in that radioreceptors assays can be devised for a whole pharmacological class and not only for one drug as it is the case for classical physico-chemical techniques. For all these reasons future of radioreceptor assay in pharmacology appears promising [fr

  14. Assay optimization for molecular detection of Zika virus

    NARCIS (Netherlands)

    Corman, Victor M.; Rasche, Andrea; Baronti, Cecile; Aldabbagh, Souhaib; Cadar, Daniel; Reusken, Chantal Bem; Pas, Suzan D.; Goorhuis, Abraham; Schinkel, Janke; Molenkamp, Richard; Kümmerer, Beate M.; Bleicker, Tobias; Brünink, Sebastian; Eschbach-Bludau, Monika; Eis-Hübinger, Anna M.; Koopmans, Marion P.; Schmidt-Chanasit, Jonas; Grobusch, Martin P.; de Lamballerie, Xavier; Drosten, Christian; Drexler, Jan Felix

    2016-01-01

    To examine the diagnostic performance of real-time reverse transcription (RT)-polymerase chain reaction (PCR) assays for Zika virus detection. We compared seven published real-time RT-PCR assays and two new assays that we have developed. To determine the analytical sensitivity of each assay, we

  15. Thyroglobulin (Tg) Testing Revisited: Tg Assays, TgAb Assays, and Correlation of Results With Clinical Outcomes.

    Science.gov (United States)

    Netzel, Brian C; Grebe, Stefan K G; Carranza Leon, B Gisella; Castro, M Regina; Clark, Penelope M; Hoofnagle, Andrew N; Spencer, Carole A; Turcu, Adina F; Algeciras-Schimnich, Alicia

    2015-08-01

    Measurement of thyroglobulin (Tg) by mass spectrometry (Tg-MS) is emerging as a tool for accurate Tg quantification in patients with anti-Tg autoantibodies (TgAbs). The objective of the study was to perform analytical and clinical evaluations of two Tg-MS assays in comparison with immunometric Tg assays (Tg-IAs) and Tg RIAs (Tg-RIAs) in a cohort of thyroid cancer patients. A total of 589 samples from 495 patients, 243 TgAb-/252 TgAb+, were tested by Beckman, Roche, Siemens-Immulite, and Thermo-Brahms Tg and TgAb assays, two Tg-RIAs, and two Tg-MS assays. The frequency of TgAb+ was 58%, 41%, 27%, and 39% for Roche, Beckman, Siemens-Immulite, and Thermo-Brahms, respectively. In TgAb- samples, clinical sensitivities and specificities of 100% and 74%-100%, respectively, were observed across all assays. In TgAb+ samples, all Tg-IAs demonstrated assay-dependent Tg underestimation, ranging from 41% to 86%. In TgAb+ samples, the use of a common cutoff (0.5 ng/mL) for the Tg-MS, three Tg-IAs, and the USC-RIA improved the sensitivity for the Tg-MSs and Tg-RIAs when compared with the Tg-IAs. In up to 20% of TgAb+ cases, Tg-IAs failed to detect Tg that was detectable by Tg-MS. In Tg-RIAs false-high biases were observed in TgAb+ samples containing low Tg concentrations. Tg-IAs remain the method of choice for Tg quantitation in TgAb- patients. In TgAb+ patients with undetectable Tg by immunometric assay, the Tg-MS will detect Tg in up to 20% additional cases. The Tg-RIA will detect Tg in approximately 35% cases, but a significant proportion of these will be clinical false-positive results. The undetectable Tg-MS seen in approximately 40% of TgAb+ cases in patients with disease need further evaluation.

  16. Solid phase radioimmunoassays using labelled antibodies: a conceptual framework for designing assays

    International Nuclear Information System (INIS)

    Kalmakoff, J.; Parkinson, A.J.; Crawford, A.M.; Williams, B.R.G.

    1977-01-01

    A simple theoretical model for the antigen-antibody reaction is presented and used to evaluate the optimum conditions for designing solid phase radioimmunoassays (RIA) using labelled antibodies. Both theoretical and experimental data are presented, using a wide variety of antigens and their corresponding antibodies. The types of RIA described include the direct, the indirect, the direct sandwich assays for detecting either antigen or antibody. The experimental results confirm in a semiquantitative manner that the greatest sensitivity of the RIA is achieved when the smallest amount of labelled antibody is used, that whenever possible the antigen/antibody ratio should be greater than unity(>1), and that the formation of the antigen-antibody complex is dependent on the mass action effect

  17. Study of antibody immobilization on different magnetic particles utilized for the radioimmunoassay (RIA) and immunoradiometric assay (IRMA) of hormones

    International Nuclear Information System (INIS)

    Ribela, M.T.C.P.; Peroni, C.N.; Bartolini, P.

    1996-01-01

    A study was carried out on antibody immobilization on three different types of magnetic particles: plain magnetite (Institute of Isotopes, Hungary), silanized magnetite (Institute of Atomic Energy, China) and Magnetizable cellulose (SCIPAC, UK). For radioimmunoassay (RIA) applications an efficient 2 nd antibody (AB)-coupled magnetic solid phase, utilizing plain magnetite and a purified anti-rabbit IgG antibody (Trilab, Brazil), was prepared. A consistent bias, detected in comparison with a well known commercial magnetic solid phase kit, was practically eliminated by modifying the coupling and saturation procedure. Concerning two-site IRMA application, an extensive study was carried out on the matching and selection of anti-hTSH antibodies that could be used for capture and detection. Very satisfactory results were obtained with the three types of magnetic particles using different monoclonal and polyclonal antibodies and in particular, two partners anti-hTSH mABs from the National Institute of Health of Thailand. Utilizing also a recombinant hTSH standard preparation, calibrated and distributed by our laboratory (IPEN-CNEN/SP, Brazil), it was possible to obtain a complete set of in-house reagents for hTSH IRMA, prepared and tested under IAEA support. (author). 11 refs, 4 figs, 12 tabs

  18. A study on the CEA and AFP in Serum of Toombak Users and Smokers in Sudan using Immunoradiometric Assays

    International Nuclear Information System (INIS)

    Abdalla, O.M.; Hassan, A.M.; Shabbo, N.M.; Khalid, M.M.; El-amin, A.M.; Ali, N.I.

    2003-01-01

    Approximately 42% of the sudanese population use toombak as smokers tobacco. Tobacco specific N-nitroso compounds have been detected at high concentration in toombak. This study focused on the possible carcinogenicity of those compounds through the measurement of serum CEA and serum AFP in both tombak users and smokers. 160 subjects were involved with the average age of 32 years ranging from 20 to 60 years. These 160 subjects were categorized into 3 groups (control, smokers, and tombak users). Serum CEA and AFP were measured using an IRMA technique. The mean AFP level in the control, tombak users and smokers groups were 0.94, 1.98 and 2.34 Ku/1 respectively. There is a significant difference between the means serum AFP level in both smokers and tombak users and control group, p=0.0045 and p=0.0049 respectively. T 13.2%of the tombak users and 23.5% of smokers have had serum AFP levels more than upper limit of the normal range (0-3-28 Ku/1) serum CEA level in control group ranged from 0 to 5.28 μg/1. The mean serum CEA levels of the tombak users and smokers was not differ significantly from that of the control group (p>0.05). But 12.7% of the tombak users and 14.7 of the smokers have had CEA level more than the upper limit of that of control. The relation between the duration of smoking and the level of CEA and AFP as well as the effect of age of subjects on the level of these analyte were studied. The results show no significant correlations where p>0.05

  19. A study on the CEA and AFP in serum of toombak users and smokers in Sudan using immunoradiometric assays

    International Nuclear Information System (INIS)

    Abdalla, O.M.; Hassan, A.M; Shabo, N.M.; Khalid, M.M.; El-amin, A.M.; Ali, N.I.

    2003-01-01

    Approximately 24% of the Sudanese population use toombak as smokeless tobacco. Tobacco specific N-nitro compounds have been detected at high concentration in toombak. this study focused on the possible carcinogenicity of those compounds through the measurement of serum CEA and serum AFP in both toombak users and smokers. 180 subjects were involved with the average age of 32 years ranging from 20 to 60 years. These 160 subjects were categorized into 3 groups (control, smokers, and toombak users). Serum CEA and AFP were measured using an IRMA technique. The mean AFP level in the control, toombak users and smokers group were 0.94, 1.98 and 2.34 Ku/l respectively. There is a significant difference between the means of serum AFP level in both smokers and toombak users and control group, p=0.0045 and p=0.0049 respectively. 13.2% of the toombak users and 23.5% of smokers have had serum AFP levels more than the upper limit of the normal range (0-3.28 Ku/l). Serum CEA level in control group ranged from 0 to 5.28μg/l. The mean serum CEA levels of the toombak users and smokers was not differ significantly from that of the control group (p>0.05). but 12.7% of the toombak users and 14.7 of the smokers have had CEA level more than the upper limit of that of control. The relation between the duration of smoking and the level of CEA and AFP as well as the effect of age of subjects on the level of these analyte were studied> The results show no significant correlations where p>0.05. (Author)

  20. Assessment and reduction of comet assay variation in relation to DNA damage: studies from the European Comet Assay Validation Group

    DEFF Research Database (Denmark)

    Møller, Peter; Möller, Lennart; Godschalk, Roger W L

    2010-01-01

    The alkaline single cell gel electrophoresis (comet) assay has become a widely used method for the detection of DNA damage and repair in cells and tissues. Still, it has been difficult to compare results from different investigators because of differences in assay conditions and because the data...... are reported in different units. The European Comet Assay Validation Group (ECVAG) was established for the purpose of validation of the comet assay with respect to measures of DNA damage formation and its repair. The results from this inter-laboratory validation trail showed a large variation in measured level...... reliability for the measurement of DNA damage by the comet assay but there is still a need for further validation to reduce both assay and inter-laboratory variation....