Sample records for direct heat utilization

  1. Geothermal direct-heat utilization assistance

    The report summarizes activities of the Geo-Heat Center (GHC) at Oregon Institute of Technology for the first quarter of Fiscal Year 1995. It describes contacts with parties during this period related to assistance with geothermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, resources and equipment. Research is also being conducted on geothermal energy cost evaluation, low-temperature geothermal resource assessment, use of silica waste from the Cerro Prieto geothermal field as construction materials and geothermal heat pumps. Outreach activities include the publication of a quarterly bulletin on direct heat applications and dissemination of information on low-temperature geothermal resources and utilization.

  2. Direct Heat Utilization of Geothermal Resources Worldwide 2005

    Lund, John W.


    Direct utilization of geothermal energy consists of various forms for heating and cooling instead of converting the energy for electric power generation. The geothermal resources that can be utilized are in the lower temperature range that are more wide-spread than the higher temperature resources used for electricity generation. The major areas of direct utilization are: heating of swimming pools and for balneology; space heating and cooling including district heating; agriculture applications (greenhouse heating and crop drying); aquaculture applications; industrial processing; and geothermal heat pumps. Direct utilization projects are reported in 72 countries with an installed capacity of 28,268 MWt and annual energy use of 273,372 TJ (75,943 GWh) reported in 2005. The equivalent annual savings in fuel oil amounts to 170 million barrels (25.4 million tonnes) and 24 million tonnes in carbon emissions to the atmosphere. Recent trends are to combined geothermal heat and power projects in order to maximize the use of the resource and improve the economics of the project. With the recent increases in fossil fuel prices, it is estimated that direct utilizations will more than double in the next 10 years.

  3. Geothermal Direct-Heat Utilization Assistance - Final Report

    J. W. Lund


    The Geo-Heat Center provided (1) direct-use technical assistance, (2) research, and (3) information dissemination on geothermal energy over an 8 1/2 year period. The center published a quarterly bulletin, developed a web site and maintained a technical library. Staff members made 145 oral presentations, published 170 technical papers, completed 28 applied research projects, and gave 108 tours of local geothermal installations to 500 persons.

  4. Geothermal direct-heat utilization assistance: Quarterly project progress report, January--March 1995



    The report summarizes geothermal activities of the Geo-Heat Center at Oregon Institute of Technology for the second quarter of FY-95. It describes 92 contacts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, resources and equipment. Research activities are summarized on geothermal energy cost evaluation, low temperature resource assessment and ground-source heat pump case studies and utility programs. Outreach activities include the publication of a geothermal direct heat Bulletin, dissemination of information, geothermal library, and progress monitor reports on geothermal resources and utilization.

  5. Geothermal direct-heat utilization assistance. Quarterly project progress report, January--March 1996



    This report summarizes geothermal technical assistance, R&D, and technology transfer activities of the Geo-Heat Center. It describes 95 contacts with parties during this period related to technical assistance with goethermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment, economics, and resources. Research activities are summarized on geothermal district heating system cost evaluation and silica waste utilization project. Outreach activities include publication of a geothermal direct use Bulletin, dissemination of information, goethermal library, technical papers and seminars, and progress monitor reports on geothermal resources and utilization.

  6. Geothermal direct-heat utilization assistance. Quarterly project progress report, July 1995--September 1995

    Lienau, P.


    The report summarizes geothermal technical assistance, R&D and technology transfer activities of the Geo-Heat Center at Oregon Institute of Technology for the fourth quarter of FY-95. It describes 80 contacts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment and resources. Research activities are summarized on low-temperature resource assessment, geothermal energy cost evaluation and marketing strategy for geothermal district heating. Outreach activities include the publication of a geothermal direct use Bulletin, dissemination of information, geothermal library, technical papers and seminars, and progress monitor reports on geothermal resources and utilization.

  7. Geothermal direct-heat utilization assistance. Quarterly report, October--December 1996



    This report summarizes geothermal technical assistance, R&D and technology transfer activities of the Geo-Heat Center at Oregon Institute of Technology for the first quarter of FY-97. It describes 174 contracts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment, economics and resources. Research activities are summarized on greenhouse peaking. Outreach activities include the publication of a geothermal direct use Bulletin, dissemination of information, geothermal library, technical papers and seminars, and progress monitor reports on geothermal resources and utilization.

  8. Geothermal direct-heat utilization assistance. Quarterly project progress report, January--March 1994


    The Geo-Heat Center provides technical assistance on geothermal direct heat applications to developers, consultants and the public which could include: data and information on low-temperature (< 1500 C) resources, space and district heating, geothermal heat pumps, greenhouses, aquaculture, industrial processes and other technologies. This assistance could include preliminary engineering feasibility studies, review of direct-use project plans, assistance in project material and equipment selection, analysis and solutions of project operating problems, and information on resources and utilization. The following are brief descriptions of technical assistance provided during the second quarter of the program.

  9. Geothermal direct-heat utilization assistance. Quarterly report, January - March 1997

    Lienau, P.


    This report summarizes geothermal technical assistance, R&D and technology transfer activities of the Geo-Heat Center at Oregon Institute of Technology for the second quarter of FY-97. It describes 176 contacts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment, economics and resources. Research activities are summarized on well pumping in commercial groundwater heat pump systems. A memorandum of understanding between the GHC and EIA is described. Work accomplishments on the Guidebook are discussed. Outreach activities include the publication of a geothermal direct use Bulletin, dissemination of information, geothermal library, technical papers and seminars, and progress monitor reports on geothermal resources and utilization.

  10. Geothermal direct-heat utilization assistance. Quarterly project progress report, July 1994--September 1994


    This paper is a third quarter 1994 report of activities of the Geo-Heat Center of Oregon Institute of Technology. It describes contacts with parties during this period related to assistance with geothermal direct heat applications. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, resources, and equipment. Research is also being conducted on failures of vertical lineshaft turbines in geothermal wells.

  11. Geothermal direct-heat utilization assistance. Quarterly project progress report, July 1996--September 1996. Federal Assistance Program

    Lienau, P.


    This report summarizes geothermal technical assistance, R&D and technology transfer activities of the Geo-Heat Center at Oregon Institute of Technology for the fourth quarter of FY-96. It describes 152 contacts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment, economics and resources. Research activities are summarized on greenhouse peaking. Outreach activities include the publication of a geothermal direct use Bulletin, dissemination of information, geothermal library, technical papers and seminars, and progress monitor reports on geothermal resources and utilization.

  12. Geothermal direct-heat utilization assistance: Federal assistance program. Quarterly project progress report, October--December 1995



    The report summarizes geothermal technical assistance, R&D and technology transfer activities of the Geo-Heat Center at Oregon Institute of Technology for the first quarter of FY-96. It describes 90 contacts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment and resources. Research activities are summarized on low-temperature resource assessment, geothermal district heating system cost evaluation and silica waste utilization project. Outreach activities include the publication of a geothermal direct use Bulletin, dissemination of information, geothermal library, technical papers and seminars, development of a webpage, and progress monitor reports on geothermal resources and utilization.

  13. Geothermal direct-heat utilization assistance. Quarterly project progress report, July--September 1997



    This report summarizes geothermal technical assistance, R and D and technology transfer activities of the Geo-Heat Center at Oregon Institute of Technology for the fourth quarter of FY-97 (July--September 1997). It describes 213 contacts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with include requests for general information including maps, geothermal heat pumps, resource and well data, space heating and cooling, greenhouses, acquaculture, equipment, district heating, resorts and spas, and industrial applications. Research activities include the completion of a Comprehensive Greenhouse Developer Package. Work accomplished on the revision of the Geothermal Direct Use Engineering and Design Guidebook are discussed. Outreach activities include the publication of the Quarterly Bulletin (Vol. 18, No. 3), dissemination of information mainly through mailings of publications, geothermal library acquisition and use, participation in workshops, short courses, and technical meetings by the staff, and progress monitor reports on geothermal activities.

  14. Geothermal direct-heat utilization assistance. Quarterly project progress report, October--December 1997



    This report summarizes geothermal technical assistance, R and D and technology transfer activities of the Geo-Heat Center at Oregon Institute of Technology for the first quarter of FY-98 (October--December 1997). It describes 216 contacts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with include requests for general information including maps and material for high school debates, and material on geothermal heat pumps, resource and well data, space heating and cooling, greenhouses, aquaculture, equipment, district heating, resorts and spas, industrial applications, electric power and snow melting. Research activities include work on model construction specifications of lineshaft submersible pumps and plate heat exchangers, a comprehensive aquaculture developer package and revisions to the Geothermal Direct Use Engineering and Design Guidebook. Outreach activities include the publication of the Quarterly Bulletin (Vol. 18, No. 4) which was devoted entirely to geothermal activities in South Dakota, dissemination of information mainly through mailings of publications, tours of local geothermal uses, geothermal library acquisition and use, participation in workshops, short courses and technical meetings by the staff, and progress monitor reports on geothermal activities.

  15. Direct utilization of geothermal energy for space and water heating at Marlin, Texas. Final report

    Conover, M.F.; Green, T.F.; Keeney, R.C.; Ellis, P.F. II; Davis, R.J.; Wallace, R.C.; Blood, F.B.


    The Torbett-Hutchings-Smith Memorial Hospital geothermal heating project, which is one of nineteen direct-use geothermal projects funded principally by DOE, is documented. The five-year project encompassed a broad range of technical, institutional, and economic activities including: resource and environmental assessments; well drilling and completion; system design, construction, and monitoring; economic analyses; public awareness programs; materials testing; and environmental monitoring. Some of the project conclusions are that: (1) the 155/sup 0/F Central Texas geothermal resource can support additional geothermal development; (2) private-sector economic incentives currently exist, especially for profit-making organizations, to develop and use this geothermal resource; (3) potential uses for this geothermal resource include water and space heating, poultry dressing, natural cheese making, fruit and vegetable dehydrating, soft-drink bottling, synthetic-rubber manufacturing, and furniture manufacturing; (4) high maintenance costs arising from the geofluid's scaling and corrosion tendencies can be avoided through proper analysis and design; (5) a production system which uses a variable-frequency drive system to control production rate is an attractive means of conserving parasitic pumping power, controlling production rate to match heating demand, conserving the geothermal resource, and minimizing environmental impacts.

  16. Geothermal direct-heat utilization assistance. Quarterly progress report, April--June 1993


    Progress is reported on the following R&D activities: evaluation of lineshaft turbine pump problems, geothermal district heating marketing strategy, and greenhouse peaking analysis. Other activities are reported on technical assistance, technology transfer, and the geothermal progress monitor.

  17. Geothermal direct-heat utilization assistance. Quarterly progress report, January--March 1993

    Lienau, P.


    CHC (Geo-Heated Center) staff provided assistance to 103 requests from 26 states, and from Canada, Egypt, Mexico, China, Poland and Greece. A breakdown of the requests according to application include: space and district heating (19), geothermal heat pumps (24), greenhouses (10), aquaculture (4), industrial (4), equipment (3), resources (27), electric power (2) and other (20). Progress is reported on: (1) evaluation of lineshaft turbine pump problems, (2) pilot fruit drier and (3) geothermal district heating marketing tools and equipment investigation. Four presentations and two tours were conducted during the quarter, GHC Quarterly Bulletin Vol. 14, No. 4 was prepared, 14 volumes were added to the library and information was disseminated to 45 requests. Progress reports are on: (1) GHP Teleconference 93, (2) California Energy Buys Glass Mountain Prospect from Unocal and Makes Deal for Newberry Caldera, (3) New Power Plant Planned, (4) Vale to Get Power Plant, (5) BPA Approves Geothermal Project, (6) Update: San Bernardino Reservoir Study, (7) Twenty-nine Palms Geothermal Resources, (8) Geo-Ag Heat Center, Lake County, and (9) Update: Geothermal Wells at Alturas.

  18. Geothermal direct-heat utilization assistance. Quarterly project progress report, April--June 1993

    Lienau, P.


    Technical assistance was provided to 60 requests from 19 states. R&D progress is reported on: evaluation of lineshaft turbine pump problems, geothermal district heating marketing strategy, and greenhouse peaking analysis. Two presentations and one tour were conducted, and three technical papers were prepared. The Geothermal Progress Monitor reported: USGS Forum on Mineral Resources, Renewable Energy Tax Credits Not Working as Congress Intended, Geothermal Industry Tells House Panel, Newberry Pilot Project, and Low-Temperature Geothermal Resources in Nevada.

  19. Evaluation of energy roof direct utilization

    Lazzarin, R.; Rossetto, L.; Viero, L.


    Energy roofs are roofing systems equipped with channels which allow both solar and atmospheric energy collection. They were conceived as cold source for heat pump systems. The behavious of an energy roof in DHW direct heating was studied; this might extend energy roof utilization all year long. The estimates were performed through more reliable recently proposed correlations for wind convection heat transfer coefficients. The advantage of annual energy roof utilization in DHW direct heating is predictable.

  20. Direct Utilization of Geothermal Energy

    John W. Lund


    Full Text Available The worldwide application of geothermal energy for direct utilization is reviewed. This paper is based on the world update for direct-use presented at the World Geothermal Congress 2010 in Bali, Indonesia (WGC2010 [1] which also includes material presented at three world geothermal congresses in Italy, Japan and Turkey (WGC95, WGC2000 and WGC2005. This report is based on country update papers prepared for WGC2010 and data from other sources. Final update papers were received from 70 countries of which 66 reported some direct utilization of geothermal energy for WGC2010. Twelve additional countries were added to the list based on other sources of information. The 78 countries having direct utilization of geothermal energy, is a significant increase from the 72 reported in 2005, the 58 reported in 2000, and the 28 reported in 1995. An estimate of the installed thermal power for direct utilization at the end of 2009, reported from WGC2010 is 48,493 MWt, almost a 72 % increased over the 2005 data, growing at a compound rate of 11.4% annually with a capacity factor of 0.28. The thermal energy used is 423,830 TJ/year (117,740 GWh/yr, about a 55% increase over 2005, growing at a compound rate of 9.2% annually. The distribution of thermal energy used by category is approximately 47.2% for ground-source heat pumps, 25.8% for bathing and swimming (including balneology, 14.9% for space heating (of which 85% is for district heating, 5.5% for greenhouses and open ground heating, 2.8% for industrial process heating, 2.7% for aquaculture pond and raceway heating, 0.4% for agricultural drying, 0.5% for snow melting and cooling, and 0.2% for other uses. Energy savings amounted to 250 million barrels (38 million tonnes of equivalent oil annually, preventing 33 million tonnes of carbon and 107 million tonnes of CO2 being release to the atmosphere which includes savings in geothermal heat pump cooling (compared to using fuel oil to generate electricity.

  1. Geothermal direct-heat utilization assistance. Federal Assistance Program quarterly project progress report, April 1--June 30, 1998



    This report summarizes geothermal technical assistance, R and D and technology transfer activities of the Geo-Heat Center at Oregon Institute of Technology for the third quarter of FY98 (April--June, 1998). It describes 231 contacts with parties during this period related to technical assistance with geothermal direct heat projects. Areas dealt with included requests for general information including material for high school and university students, and material on geothermal heat pumps, resource and well data, spacing heating and cooling, greenhouses, aquaculture, equipment, district heating, resorts and spas, industrial applications, snow melting and electric power. Research activities include work on model construction specifications for line shaft submersible pumps and plate heat exchangers, and a comprehensive aquaculture developers package. A brochure on Geothermal Energy in Klamath County was developed for state and local tourism use. Outreach activities include the publication of the Quarterly Bulletin (Vol. 19, No. 2) with articles on research at the Geo-Heat Center, sustainability of geothermal resources, injection well drilling in Boise, ID and a greenhouse project in the Azores. Other outreach activities include dissemination of information mainly through mailings of publications, tours of local geothermal uses, geothermal library acquisitions and use, participation in workshops, short courses and technical meetings by the staff, and progress monitor reports on geothermal activities.

  2. Heat utilization (2); Netsuriyo (2)

    Akizawa, Jun [Tokyo University of Agriculture and Tecnology, Tokyo (Japan)


    (102) The application of the carbon dioxide separation and collection system using CPC to the thermal power plant. (103) The effect of the scattered light on collection of heat of solar pond. (104) The development of the Basin- multiple-effect compound type solar heat distiller. (Production and performance test of the small plant.) (105) On the plan of the new-model solar heat engine. (106) The performance prediction of solar power system using Stirling engine. (Part 2 The case in which the divided condenser was used.) (107) The trial manufacture of the sun cooker. It was announced and was made of 6 from various regions in this session on the heat utilization. On the multiple-effect compound type solar heat distiller, the comment that the feasibility could be expected from the simple structure was made. And, the question on system operation of allocation of the distillation quantity, etc. was actively made. On 2 of plan of the new-model solar heat engine and trial manufacture of the sun cooker, it was not possible that the publicator came for the aged to Okinawa, and instead, it became an announcement by tape and OHP blown in self. Though it was the form which there was no in the convention, it could be heard of that it is major field. It was thought, because there was some an announcement on the Stirling engine in the this session, place be able to. And, photograph and experimental result of the prototype are also included for the announcement of the sun cooker and want to desire the opportunities which hear the direct announcement. It wants to be thankful for hardship Mr.Naito the Science and Technology Agency National Aerospace Laboratory that it carried tape and OHP and assisted the announcement. The biomass. (108) The measurement approach of the environment resuscitation acceleration effect. (109) The basic research on the biogas storage by the clathration. The behavior of the carbon dioxide in the clathrate generation. (111) The solar thermal application

  3. Recovery and utilization of waste heat

    Al-Rabghi, O.M.; Beirutty, M.; Akyurt, M.; Najjar, Y.; Alp, T. (King Abdulaziz Univ., Jeddah (Saudi Arabia). Coll. of Engineering)


    A review of waste heat recovery and utilization is presented. The potential for re-using the otherwise waste heat in different branches of industry is discussed. Traditional and new ways to recover the discharged heat from industrial equipment are illustrated. It is concluded that there exist numerous opportunities for recuperating and using waste heat. (author)

  4. Solid waste utilization: incineration with heat recovery

    Boegly, W.J. Jr.


    As a part of the Integrated Community Energy Systems (ICES) Program, Technology Evaluations, this evaluation considers the potential utilization of municipal solid wastes as an energy source by use of incineration with heat recovery. Subjects covered include costs, design data, inputs and outputs, and operational problems. Two generic types of heat recovery incinerators are evaluated. The first type, called a waterwall incinerator, is one in which heat is recovered directly from the furnace using water circulated through tubes imbedded in the furnace walls. This design normally is used for larger installations (>200 tons/day). The second type, a starved-air incinerator is used mainly in smaller sizes (<100 tons/day). Burning is performed in the incinerator, and heat recovery is obtained by the use of heat exchangers on the flue gases from the incinerator. Currently there are not many installations of either type in the United States; however, interest in this form of solid-waste handling appears to be increasing.

  5. Waste heat utilization in industrial processes

    Weichsel, M.; Heitmann, W.


    A survey is given of new developments in heat exchangers and heat pumps. With respect to practical applications, internal criteria for plant operation are discussed. Possibilities of government support are pointed out. Waste heat steam generators and waste heat aggregates for hot water generation or in some cases for steam superheating are used. The possibilities of utilization can be classified according to the economic improvements and according to their process applications, for example, gascooling. Examples are presented for a large variety of applications.

  6. NGNP Process Heat Utilization: Liquid Metal Phase Change Heat Exchanger

    Piyush Sabharwall; Mike Patterson; Vivek Utgikar; Fred Gunnerson


    One key long-standing issue that must be overcome to fully realize the successful growth of nuclear power is to determine other benefits of nuclear energy apart from meeting the electricity demands. The Next Generation Nuclear Plant (NGNP) will most likely be producing electricity and heat for the production of hydrogen and/or oil retrieval from oil sands and oil shale to help in our national pursuit of energy independence. For nuclear process heat to be utilized, intermediate heat exchange is required to transfer heat from the NGNP to the hydrogen plant or oil recovery field in the most efficient way possible. Development of nuclear reactor - process heat technology has intensified the interest in liquid metals as heat transfer media because of their ideal transport properties. Liquid metal heat exchangers are not new in practical applications. An important rational for considering liquid metals is the potential convective heat transfer is among the highest known. Thus explains the interest in liquid metals as coolant for intermediate heat exchange from NGNP. For process heat it is desired that, intermediate heat exchangers (IHX) transfer heat from the NGNP in the most efficient way possible. The production of electric power at higher efficiency via the Brayton Cycle, and hydrogen production, requires both heat at higher temperatures and high effectiveness compact heat exchangers to transfer heat to either the power or process cycle. Compact heat exchangers maximize the heat transfer surface area per volume of heat exchanger; this has the benefit of reducing heat exchanger size and heat losses. High temperature IHX design requirements are governed in part by the allowable temperature drop between the outlet and inlet of the NGNP. In order to improve the characteristics of heat transfer, liquid metal phase change heat exchangers may be more effective and efficient. This paper explores the overall heat transfer characteristics and pressure drop of the phase change

  7. Direct utilization of geothermal heat in cascade application to aquaculture and greenhouse systems at Navarro College. Final report, March 1, 1979-September 30, 1984

    Smith, K.


    This final report documents the Navarro College geothermal use project, which is one of nineteen direct-use geothermal projects funded principally by DOE. The six-year project encompassed a broad range of technical, institutional, and economic activities including: resource and environmental assessment; well drilling and completion; system design, construction, and monitoring; economic analysis; and public awareness programs. Some of the project conclusions are that: (1) the 130/sup 0/F Central Texas geothermal resource can support additional geothermal development; (2) private sector economic incentives currently exist which encourage commercial development of this geothermal resource; (3) potential uses for this geothermal resource include water and space heating, aquacultural and agricultural heating uses, and fruit and vegetable dehydration; (4) high maintenance costs arising from the geofluids' scaling and corrosion characteristics can be avoided through proper analysis and design.

  8. Direct utilization of geothermal heat in cascade application to aquaculture and greenhouse systems at Navarro College. Final report, March 1, 1979-September 30, 1984

    Smith, K.


    This final report documents the Navarro College geothermal use project, which is one of nineteen direct-use geothermal projects funded principally by DOE. The six-year project encompassed a broad range of technical, institutional, and economic activities including: resource and environmental assessment; well drilling and completion; system design, construction, and monitoring; economic analysis; and public awareness programs. Some of the project conclusions are that: (1) the 130/sup 0/F Central Texas geothermal resource can support additional geothermal development; (2) private sector economic incentives currently exist which encourage commercial development of this geothermal resource; (3) potential uses for this geothermal resource include water and space heating, aquacultural and agricultural heating uses, and fruit and vegetable dehydration; (4) high maintenance costs arising from the geofluids' scaling and corrosion characteristics can be avoided through proper analysis and design.

  9. Overview of waste heat utilization systems

    Bailey, M. M.


    The heavy truck diesel engine rejects a significant fraction of its fuel energy in the form of waste heat. Historically, the Department of Energy has supported technology efforts for utilization of the diesel exhaust heat. Specifically, the Turbocompound and the Organic Rankine Cycle System (ORCS) have demonstrated that meaningful improvements in highway fuel economy can be realized through waste heat utilization. For heat recovery from the high temperature exhaust of future adiabatic diesel engines, the DOE/NASA are investigating a variety of alternatives based on the Rankine, Brayton, and Stirling power cycles. Initial screening results indicate that systems of this type offer a fuel savings advantage over the turbocompound system. Capital and maintenance cost projections, however, indicate that the alternative power cycles are not competitive on an economic payback basis. Plans call for continued analysis in an attempt to identify a cost effective configuration with adequate fuel savings potential.

  10. System Analysis on Absorption Chiller Utilizing Intermediate Wasted Heat

    Yamada, Miki; Suzuki, Hiroshi; Usui, Hiromoto

    A system analysis has been performed for the multi-effect absorption chiller (MEAC) applied as a bottoming system of 30kW class hybrid system including micro gas turbine (MGT) and solid oxide fuel cell (SOFC) hybrid system. In this paper, an intermediate wasted heat utilization (IWHU) system is suggested for lifting up the energy efficiency of the whole system and coefficient of performance (COP) of MEAC. From the results, the suggested IWHU system was found to show the very high energy efficiency compared with a terminal wasted heat utilization (TWHU) system that uses only the heat exhausted from the terminal of MGT/SOFC system. When TWHU system is applied for MEAC, the utilized heat from the MGT/SOFC system is found to remain low because the temperature difference between the high temperature generator and the wasted heat becomes small. Then, the energy efficiency does not become high in spite of high COP of MEAC. On the other hand, the IWHU system could increase the utilized heat for MEAC as performs effectively. The exergy efficiency of IWHU system is also revealed to be higher than that of a direct gas burning system of MEAC, because the wasted heat is effectively utilized in the IWHU system.

  11. Solar heat utilization for adsorption cooling device

    Malcho Milan


    Full Text Available This article deals with possibility of solar system connection with adsorption cooling system. Waste heat from solar collectors in summer is possible to utilize in adsorption cooling systems, which desorption temperatures have to be lower than temperature of heat transport medium operation temperature. For verification of work of this system was constructed on the Department of power engineering on University of Zilina solar adsorption cooling device.

  12. Overview of waste heat utilization techniques

    Olszewski, M.


    Power plants annually reject about 11 x 10/sup 9/ GJ (11 x 10/sup 15/ Btu) of low-grade heat to the atmosphere. Typically, this heat is found in the large quantities of cooling water necessary to condense the steam in the power-generating cycle. Such cooling water is generally discharged in the range of 15 to 43/sup 0/C (60 to 110/sup 0/F) depending on the temperature of the available inlet water, quantity circulated, plant load, and heat-rejection system used. A number of possible uses have been suggested for this low-grade heat, including: greenhouse horticulture; soil heating (both open field and in greenhouses); spray irrigation for frost protection; organic waste treatment (particularly for algae or biomass production); and aquaculture/mariculture. To date greenhouse and aquaculture/mariculture systems have received the most attention and have, therefore, progressed farthest. This paper describes several innovative techniques that utilize power-plant reject heat for these applications. Schematic descriptions are given for these techniqes and a brief review of the project status is provided. The major efforts to utilize reject heat for agricultural purposes are described not only for the U.S., but efforts in Canada, France, West Germany, and the USSR are noted.

  13. Purged window apparatus utilizing heated purge gas

    Ballard, Evan O.


    A purged window apparatus utilizing tangentially injected heated purge gases in the vicinity of electromagnetic radiation transmitting windows, and a tapered external mounting tube to accelerate these gases to provide a vortex flow on the window surface and a turbulent flow throughout the mounting tube. Use of this apparatus prevents backstreaming of gases under investigation which are flowing past the mouth of the mounting tube which would otherwise deposit on the windows. Lengthy spectroscopic investigations and analyses can thereby be performed without the necessity of interrupting the procedures in order to clean or replace contaminated windows.

  14. Induction and direct resistance heating theory and numerical modeling

    Lupi, Sergio; Aliferov, Aleksandr


    This book offers broad, detailed coverage of theoretical developments in induction and direct resistance heating and presents new material on the solution of problems in the application of such heating. The physical basis of induction and conduction heating processes is explained, and electromagnetic phenomena in direct resistance and induction heating of flat workpieces and cylindrical bodies are examined in depth. The calculation of electrical and energetic characteristics of induction and conduction heating systems is then thoroughly reviewed. The final two chapters consider analytical solutions and numerical modeling of problems in the application of induction and direct resistance heating, providing industrial engineers with the knowledge needed in order to use numerical tools in the modern design of installations. Other engineers, scientists, and technologists will find the book to be an invaluable reference that will assist in the efficient utilization of electrical energy.

  15. Direct contact heat exchangers for space

    Taussig, R. T.; Thayer, W. J.; Lo, V. C. H.; Sakins, K. M.; Bruckner, A. P.


    Direct contact heat exchanger concepts have been investigated for use in space, including droplet vortex heat exchangers, coflowing droplet heat exchangers, electrostatically driven heat exchangers, and belt and disk heat exchangers. These concepts are characterized by a low heat exchanger mass per unit of heat transferred, low pressure losses, high reliability, and compactness in design. Operation in zero-G poses unique problems for those direct contact heat exchangers which require separation of two fluid media after heat transfer is completed. Other problems include maintenance of good heat transfer coefficients in the absence of buoyant forces, exposure of heat transfer media to vacuum conditions for certain applications, and materials compatibility. A preliminary systems analysis indicates the potential for substantial weight reductions in turbine Brayton cycle space power systems for output powers above several MW(e). Based on the status of current technology and the results of this analysis, recommendations are made for the most attractive applications and the R&D required to ready a direct contact heat exchanger for use in space.

  16. Utilizing Radioisotope Power System Waste Heat for Spacecraft Thermal Management

    Pantano, David R.; Dottore, Frank; Tobery, E. Wayne; Geng, Steven M.; Schreiber, Jeffrey G.; Palko, Joseph L.


    An advantage of using a Radioisotope Power System (RPS) for deep space or planetary surface missions is the readily available waste heat, which can be used for a number of beneficial purposes including: maintaining electronic components within a controlled temperature range, warming propulsion tanks and mobility actuators, and maintaining liquid propellants above their freezing temperature. Previous missions using Radioisotope Thermoelectric Generators (RTGs) dissipated large quantities of waste heat due to the low efficiency of the thermoelectric conversion technology. The next generation RPSs, such as the 110-Watt Stirling Radioisotope Generator (SRG110) will have higher conversion efficiencies, thereby rejecting less waste heat at a lower temperature and may require alternate approaches to transferring waste heat to the spacecraft. RTGs, with efficiencies of 6 to 7 percent, reject their waste heat at the relatively high heat rejection temperature of 200 C. This is an advantage when rejecting heat to space; however, transferring heat to the internal spacecraft components requires a large and heavy radiator heat exchanger. At the same time, sensitive spacecraft instruments must be shielded from the thermal radiation of the RTG. The SRG110, with an efficiency around 22 percent and 50 C nominal housing surface temperature, can readily transfer the available waste heat directly via heat pipes, thermal straps, or fluid loops. The lower temperatures associated with the SRG110 avoid the chances of overheating other scientific components, eliminating the need for thermal shields. This provides the spacecraft designers more flexibility when locating the generator for a specific mission. A common misconception with high-efficiency systems is that there is not enough waste heat for spacecraft thermal management. This paper will dispel this misconception and investigate the use of a high-efficiency SRG110 for spacecraft thermal management and outline potential methods of

  17. Solving Direct and Inverse Heat Conduction Problems

    Taler, Jan


    Presents a solution for direct and inverse heat conduction problems. This work discusses the theoretical basis for the heat transfer process in the first part. It presents selected theoretical and numerical problems in the form of exercises with their subsequent solutions in the second part

  18. Accumulation and subsequent utilization of waste heat

    Koloničný, Jan; Richter, Aleš; Pavloková, Petra


    This article aims to introduce a special way of heat accumulation and primary operating characteristics. It is the unique way in which the waste heat from flue gas of biogas cogeneration station is stored in the system of storage tanks, into the heat transfer oil. Heat is subsequently transformed into water, from which is generated the low-pressure steam. Steam, at the time of peak electricity needs, spins the special designed turbine generator and produces electrical energy.

  19. Hydrothermal industrialization: direct heat development. Final report


    A description of hydrothermal resources suitable for direct applications, their associated temperatures, geographic distribution and developable capacity are given. An overview of the hydrothermal direct-heat development infrastructure is presented. Development activity is highlighted by examining known and planned geothermal direct-use applications. Underlying assumptions and results for three studies conducted to determine direct-use market penetration of geothermal energy are discussed.

  20. In situ heat treatment process utilizing a closed loop heating system

    Vinegar, Harold J. (Bellaire, TX); Nguyen, Scott Vinh (Houston, TX)


    Systems and methods for an in situ heat treatment process that utilizes a circulation system to heat one or more treatment areas are described herein. The circulation system may use a heated liquid heat transfer fluid that passes through piping in the formation to transfer heat to the formation. In some embodiments, the piping may be positioned in at least two of the wellbores.

  1. Geothermal direct-heat study: Imperial County, California


    Potential applications of geothermal energy which would be compatible with the agricultural activities in the county were identified and a plan to attract potential users to the area was developed. The intent of the first effort was to identify general classifications of industries which could utilize geothermal heat in production processes. Two levels of analyses were utilized for this effort. Initially, activities relying on previously developed engineering and industrial concepts were investigated to determine capital costs, employment, and potential energy savings. Second, innovative concepts not yet fully developed were investigated to determine their potential applicability to the agricultural base of the county. These investigations indicated that the major potential applications of geothermal heat would involve industries related to food processing or other direct agriculture-related uses of raw materials produced or imported to the county. An implementation plan which can be utilized by the county to market direct heat applications was developed. A socioeconomics analysis examined the potential effects on the county from development of direct heat projects. The county's planning and permitting requirements for dirct heat projects were also examined.

  2. Utility Incentives for Combined Heat and Power

    This report describes the results of EPA's research and analysis into utility incentives for CHP. It provides information about utility-initiated policies, programs, and incentives for CHP systems, and includes case studies and tools and resources.

  3. Nonlinear Aspects of Heat Pump Utilization

    R. Najman


    Full Text Available This work attempts to answer the question: How much can we believe that the coefficient of performance provided by the manufacturer is correct, when a heat pump is required to face the real load coming from changes of temperature? The paper summarizes some basics of heat pump theory and describes the results of numerical models.

  4. Utilization of low-temperature heat sources for heat and power production

    Haglind, Fredrik; Elmegaard, Brian


    Low-temperature heat sources are available in many applications, ranging from waste heat from marine diesel engines, industries and refrigeration plants to biomass, geothermal and solar heat sources. There is a great potential for enhancing the utilization of these heat sources by novel thermodyn......Low-temperature heat sources are available in many applications, ranging from waste heat from marine diesel engines, industries and refrigeration plants to biomass, geothermal and solar heat sources. There is a great potential for enhancing the utilization of these heat sources by novel.......Both power production and heat pumps may benefit from the development as both technologies utilize a heat source. This makes it possible to cover the complete temperature range of low temperature sources. The development may contribute to significantly lower energy consumption in Danish industry and shipping...

  5. Smile makeover utilizing direct composite resin veneers.

    Koczarski, Michael


    Creating a beautiful smile is more than restoring a single tooth back to its proper form. One must take into account the entire aesthetic zone, along with the mechanics of restoring the teeth to proper form and function. To make this effort even more challenging, the clinician is in full control and completely accountable for making the direct composite resin restorations from which the smile is created. Patients usually won't critique the aesthetics of a posterior direct resin, but once we move into the visible smile (along with the fact that most cosmetic procedures are patient desire- and want-driven) we must be able to deliver what the patient expects. Preplanning the case and avoiding the "prep and pray" approach to the smile-design process is the cornerstone of success. Utilizing tools for the creation of the restorations, such as a preoperative wax-up and silicone putty matrix, help the clinician break the procedure down to individual restorations that when created in harmony with the pre-operative design or wax-up, will allow a final "smile design" to emerge with predictability without getting lost in the daunting task of creating the entire smile all at once. Proper use of ideal composite materials adds the final touch on creating realistic results that even the most discerning patients demand. Layering colors, utilizing differing opacities and translucencies within the restorative process, is a must. Having a "recipe" to follow simplifies the process and gives the clinician confidence that the final result will have that realistic look. All in all, the easiest way to handle a challenging case is to break it down into smaller and more manageable increments in order to ensure a predictable outcome.

  6. Geothermal direct heat applications program summary



    The use of geothermal energy for direct heat purposes by the private sector within the US has been quite limited to date. However, there is a large potential market for thermal energy in such areas as industrial processing, agribusiness, and space/water heating of commercial and residential buildings. Technical and economic information is needed to assist in identifying prospective direct heat users and to match their energy needs to specific geothermal reservoirs. Technological uncertainties and associated economic risks can influence the user's perception of profitability to the point of limiting private investment in geothermal direct applications. To stimulate development in the direct heat area, the Department of Energy, Division of Geothermal Energy, issued two Program Opportunity Notices (PON's). These solicitations are part of DOE's national geothermal energy program plan, which has as its goal the near-term commercialization by the private sector of hydrothermal resources. Encouragement is being given to the private sector by DOE cost-sharing a portion of the front-end financial risk in a limited number of demonstration projects. The twenty-two projects summarized herein are direct results of the PON solicitations.

  7. Utilization of low temperature heat for environmentally friendly electricity production

    Andreasen, Jesper Graa; Elmegaard, Brian; Haglind, Fredrik


    The focus on reduction of fossil fuelled electricity generation has increased the attention on exploitation of low grade heat as the energy source for electricity producing power plants. Low grade heat is heat, which isavailable at a low temperature, e.g. from waste heat from marine diesel engines...... and industrial processes orfrom geothermal and solar heat sources. Utilization of such heat sources makes it possible to produce electricity with no additional burning of fossil fuel, and does therefore represent an environmentally friendly alternative to fossil fuel based electricity production. Utilization...... of low grade heat is not feasible with conventional steam Rankine cycles (steam engines) due to undesirable properties of steam. Instead the organic Rankine cycle is typically used, since it enables thechoice of a working fluid, e.g. hydrocarbons or refrigerants, with desirable properties. One of the key...

  8. Nuclear power plant waste heat utilization

    Ryther, J.H.; Huke, R.E.; Archer, J.C.; Price, D.R.; Jewell, W.J.; Hayes, T.D.; Witherby, H.R.


    The possibility of using Vermont Yankee condenser effluent for commercial food growth enhancement was examined. It was concluded that for the Vermont Yankee Nuclear Station, commercial success, both for horticulture and aquaculture endeavors, could not be assured without additional research in both areas. This is due primarily to two problems. First, the particularly low heat quality of our condenser discharge, being nominally 72 +- 2/sup 0/F; and second, to the capital intensive support systems. The capital needed for the support systems include costs of pumps, piping and controls to move the heated water to growing facilities and the costs of large, efficient heat exchangers that may be necessary to avoid regulatory difficulties due to the 1958 Delaney Amendment to the U.S. Food, Drug and Cosmetics Act. Recommendations for further work include construction of a permanent aquaculture research laboratory and a test greenhouse complex based on a greenhouse wherein a variety of heating configurations would be installed and tested. One greenhouse would be heated with biogas from an adjacent anaerobic digester thermally boosted during winter months by Vermont Yankee condenser effluent. The aquaculture laboratory would initially be dedicated to the Atlantic salmon restoration program. It appears possible to raise fingerling salmon to smolt size within 7 months using water warmed to about 60/sup 0/F. The growth rate by this technique is increased by a factor of 2 to 3. A system concept has been developed which includes an aqua-laboratory, producing 25,000 salmon smolt annually, a 4-unit greenhouse test horticulture complex and an 18,000 square foot commercial fish-rearing facility producing 100,000 pounds of wet fish (brook trout) per year. The aqualab and horticulture test complex would form the initial phase of construction. The trout-rearing facility would be delayed pending results of laboratory studies confirming its commercial viability.

  9. Heat Transfer in Directional Water Transport Fabrics

    Chao Zeng


    Full Text Available Directional water transport fabrics can proactively transfer moisture from the body. They show great potential in making sportswear and summer clothing. While moisture transfer has been previously reported, heat transfer in directional water transport fabrics has been little reported in research literature. In this study, a directional water transport fabric was prepared using an electrospraying technique and its heat transfer properties under dry and wet states were evaluated, and compared with untreated control fabric and the one pre-treated with NaOH. All the fabric samples showed similar heat transfer features in the dry state, and the equilibrium temperature in the dry state was higher than for the wet state. Wetting considerably enhanced the thermal conductivity of the fabrics. Our studies indicate that directional water transport treatment assists in moving water toward one side of the fabric, but has little effect on thermal transfer performance. This study may be useful for development of “smart” textiles for various applications.

  10. Improving the performance of district heating systems by utilization of local heat boosters

    Falcone, A.; Dominkovic, D. F.; Pedersen, A. S.

    LTDH grid as they will have the strategical role of connecting the heating system with the electrical energy coming from the intermittent and fluctuating renewable energy sources such as wind and solar power. In this paper a case study of district heating system is presented and analysed. The goal......District Heating (DH) plays an important role into the Danish energy green transition towards the future sustainable energy systems. The new, 4 th generation district heating network, the so called Low Temperature District Heating (LTDH), tends to lower the supply temperature of the heat down to 40......-50°C with return temperatures of 20-30 °C. This kind of heating system has many advantages and among all of them, it allows utilization of the heat coming from low exergy heat sources, as well as to decrease the grid heat losses. Electrical energy driven heat sources are also integrated into the future...

  11. Direct Heat Integration of Independent Processes

    冯霄; 文健; 叶鑫午


    The properties of matched streams, the simultaneous operation time, and the distance betweenintegrated processes, are the main factors which determine whether the direct integration is feasible ornot. According to whether such synthetic integration is economically better than the separate integrationof each process, a mathematical formulation is established. The retrofit of reforming and arene processesin a certain petrochemical factory, which are independent each other, is chosen as a case study. By onlyconsidering the simultaneous operation time, two retrofit designs are proposed: one is that each of thetwo processes is separately integrated by itself, and the other is that the two processes are integratedcomprehensively. Under different simultaneous operation hours, the energy-saving effects and theeconomic profits of the two designs are calculated, and furthermore, the critical simultaneous operationtime for direct heat integration of the two processes is obtained. When the actual simultaneous operationtime of the two processes is longer than the critical value, the direct heat integration of the two processesis better economically, and otherwise the separate heat integration for each process should be considered.

  12. Technical and economic aspects of waste heat utilization

    Smolen Slavomir


    Full Text Available The main aim of the following presentation is the comparison and evaluation of the conditions for waste heat utilization in Germany and in Poland. This paper presents synthetically the results of economic analysis of the different technical variants. The employment of heat pumps and other heat transformers, respectively, can reduce the energy consumption, but using of those technical possibilities depends mainly on the economic aspects. The main parameters of the financial calculations were the energy and equipment costs but beyond it a number of other factors were also considered and compared, for example calculation interests, profit tax level and similar. Four different technical alternatives were analyzed, it is using of absorption heat pump, compression heat pump, heat transformer (absorption, and a special combined system with gas motor to drive of heat pump compressor. The capital value as main result of the investigations is in Poland generally lower because of relatively high investment cost and lower energy prices compared to the situation in Germany and West Europe. The basis for the presented comparative analysis was an industrial project in Germany which effected in development of concepts for waste heat using. .

  13. Urban heat evolution in a tropical area utilizing Landsat imagery

    Amanollahi, Jamil; Tzanis, Chris; Ramli, Mohammad Firuz; Abdullah, Ahmad Makmom


    Cloud cover is the main limitation of using remote sensing to study Land Use and Land Cover (LULC) change, and Land Surface Temperature (LST) in tropical area like Malaysia. In order to study LULC change and its effect on LST, the Landsat images were utilized within Geographical Information System (GIS) with the aim of removing the effect of cloud cover and image's gaps on the Digital Number (DN) of the pixels. 5356 points according to pixels coordinate which represent the 960 m to 960 m area were created in GIS environment and matched with thermal bands of the study area in remote sensing environment. The DNs of these points were processed to extract LST and imported in GIS environment to derive the temperature maps. Temperature was found to be generally higher in 2010 than in 2000. The comparison of the highest temperature area in the temperature maps with ground stations data showed that the topographical characteristics of the area, and the wind speed, and direction influence the occurrence of Urban Heat Island (UHI) effect. This study concludes that integration of remote sensing data and GIS is a useful tool in urban LST detection in tropical area.

  14. Geothermal Direct Heat Applications Program Summary



    Because of the undefined risk in the development and use of geothermal energy as a thermal energy source, the Department of Energy Division of Geothermal Energy solicited competitive proposals for field experiments in the direct use of geothermal energy. Twenty-two proposals were selected for cost-shared funding with one additional project co-funded by the State of New Mexico. As expected, the critical parameter was developing a viable resource. So far, of the twenty resources drilled, fourteen have proved to be useful resources. These are: Boise, Idaho; Elko heating Company in Nevada; Pagosa Springs, Colorado; Philip School, Philip, South Dakota; St. Mary's Hospital, Pierre, South Dakota; Utah Roses near Salt Lake City; Utah State Prison, Utah; Warm Springs State Hospital, Montana; T-H-S Hospital, Marlin, Texas; Aquafarms International in the Cochella Valley, California; Klamath County YMCA and Klamath Falls in Oregon; Susanville, California and Monroe, utah. Monroe's 164 F and 600 gpm peak flow was inadequate for the planned project, but is expected to be used in a private development. Three wells encountered a resource insufficient for an economical project. These were Madison County at Rexburg, Idaho; Ore-Ida Foods at Ontario, Oregon and Holly Sugar at Brawley, California. Three projects have yet to confirm their resource. The Navarro College well in Corsicana, Texas is being tested; the Reno, Moana, Nevada well is being drilled and the El Centro, California well is scheduled to be drilled in January 1982. The agribusiness project at Kelly Hot Springs was terminated because a significant archeological find was encountered at the proposed site. The Diamond Ring Ranch in South Dakota, and the additional project, Carrie Tingley Hospital in Truth or Consequences, New Mexico both used existing wells. The projects that encountered viable resources have proceeded to design, construct, and in the most advanced projects, to operate geothermal systems for

  15. Utilization of heat pipes for transfer heat from the flue gas into the heat transfer medium

    Lenhard Richard


    Full Text Available The contribution is listed possible application of heat pipes in systems for obtaining heat from flue gas of small heat sources. It is also stated in the contribution design an experimental device on which to study the impact of fill (the quantity, type of load at various temperature parameters (temperature heating and cooling thermal power transferred to the heat pipe. Is listed measurement methodology using heat pipes designed experimental facility, measurement results and analysis of the results obtained.

  16. Ground-source heat pump case studies and utility programs

    Lienau, P.J.; Boyd, T.L.; Rogers, R.L.


    Ground-source heat pump systems are one of the promising new energy technologies that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school and commercial building applications. In order to verify the performance, information was collected for 253 case studies from mainly utilities throughout the United States. The case studies were compiled into a database. The database was organized into general information, system information, ground system information, system performance, and additional information. Information was developed on the status of demand-side management of ground-source heat pump programs for about 60 electric utility and rural electric cooperatives on marketing, incentive programs, barriers to market penetration, number units installed in service area, and benefits.

  17. Thermal Efficiency in a Direct Contact Heat Exchanger of Gas and Liquid

    Fukuhara, Isamu; Tsuji, Katsuhiko

    Co-generation systems have many practical applications for energy-saving, utilization of various energy resources and energy recovery of waste gas. However, it is pointed out that heat exchangers of co-generation system involve some problems which are corrosion of heat surface, decrease of heat transfer rate due to accumulation of soot and NOx in waste gas. Then. the heat exchange which contacts waste gas with liquid are studied to solve the above problems. The contacting state of gas and liquid has not been researched on the direct contact heat exchanger of gas and liquid. For it is considered that the contacting state has direct effects on a thermal efficiency and gas absorption. Then, we try to investigate the contacting state of gas and liquid by experiments of heating and image processing on the direct contact heat exchanger. From the results, the contacting state of gas and liquid can be evaluate by a gas-liquid contacting area.



    Continuous Hot-Dip Galvanizing lines are widely used for the production of coated steel sheets. Quality improvement measures are of great importance for this type of line. A significant proportion of production and quality losses when operating these types of lines occurs when production is transitioning from one strip gauge/thermal cycle to another. Utilizing induction heating technology, in combination with a sophisticated control system, can dramically decrease yield losses during transiti...

  19. Geothermal direct heat applications program summary



    In 1978, the Department of Energy Division of Geothermal and Hydropower Technologies initiated a program to accelerate the direct use of geothermal energy, in which 23 projects were selected. The projects, all in the western part of the US, cover the use of geothermal energy for space conditioning (heating and cooling) and agriculture (aquaculture and greenhouses). Initially, two projects were slated for industrial processing; however, because of lack of geothermal resources, these projects were terminated. Of the 23 projects, seven were successfully completed, ten are scheduled for completion by the end of 1983, and six were terminated for lack of resources. Each of the projects is being documented from its inception through planning, drilling, and resource confirmation, design, construction, and one year of monitoring. The information is being collected, evaluated, and will be reported. Several reports will be produced, including detailed topical reports on economics, institutional and regulatory problems, engineering, and a summary final report. To monitor progress and provide a forum for exchange of information while the program is progressing, semiannual or annual review meetings have been held with all project directors and lead engineers for the past four years. This is the sixth meeting in that series. Several of the projects which have been terminated are not included this year. Overall, the program has been very successful. Valuable information has been gathered. problems have been encountered and resolved concerning technical, regulatory, and institutional constraints. Most projects have been proven to be economical with acceptable pay-back periods. Although some technical problems have emerged, they were resolved with existing off-the-shelf technologies and equipment. The risks involved in drilling for the resource, the regulatory constraints, the high cost of finance, and large front-end cost remain the key obstacles to the broad development of

  20. Device with Complex System for Heat Utilization and Reduction of Hazardous Air Emissions

    O. Kascheeva


    Full Text Available Investigations concern heat utilization and reduction of hazardous emissions occurring in residential buildings and accompanying operation of a great number of industrial enterprises in particular heat and power objects, and firstly, heat-generating units of small power located in densely populated residential areas without centralized heat supply.The investigation target is to reduce cost of heat produced by independent system of building heat supply, reduction of air pollution  due to hazardous gas emissions and reduction of heat pollution of the environment as a result of building ventilation system operation, ventilation of their internal and external sewerage network and higher reliability of their operation.The target is achieved because the device with complex system for heat utilization and reduction of hazardous air emissions has additionally an assembly tank for mixing flue gases, ventilation emissions and atmospheric air, heat pump. Evaporation zone of the pump is a condensator of the gas mixture and its condensate zone contains a heat supply line for a heat consumer. The line is equipped with assembling  and distributing collectors, pipeline connecting the heat supply line with the system of direct and return delivery water from a boiler house, a separator for division of liquid and gaseous mixture phases, neutralizing devices for separate reduction of concentrations of hazardous and odorous substances being released in gaseous and liquid portions of the mixture, a pipeline for periodic supply of air with higher concentration of hazardous and odorous substances in the boiler furnace. The supplied air is obtained as a result of its passing through gas filters at their regeneration when their exchange capacity is exhausted.

  1. Direct utilization of geothermal energy: a technical handbook

    Anderson, D.N; Lund, J.W. (eds.)


    This technical handbook includes comprehensive discussions on nature and occurrence of the geothermal resource, its development, utilization, economics, financing, and regulation. Information on pricing parameters for the direct use of geothermal energy is included as an appendix. (MRH)

  2. Direct contact heat recovery from molten salt

    Technological deficiencies associated with efficient and economical retrieval of heat energy from molten salt systems are addressed. The large latent heat of fusion stored in molten salt hydrates and other candidate phase change materials (PCM) is removed by internal boiling of a volatile heat transfer fluid (HTF). This procedure eliminates the conventional use of submerged heat exchangers which are costly and, in crystallizing salts, ineffective. The thermochemical conditions and material properties that are critical for application of this concept in environments that yield significant energy savings are investigated and defined.

  3. Heat Transmission Coefficient Measurements in Buildings Utilizing a Heat Loss Measuring Device

    Sørensen, Lars Schiøtt


    to optimize the energy performance. This paper presents a method for measuring the heat loss by utilizing a U-value meter. The U-value meter measures the heat transfer in the unit W/Km2 and has been used in several projects to upgrade the energy performance in temperate regions. The U-value meter was also...... and mechanical ventilation in the “warm countries” contribute to an enormous energy consumption and corresponding CO2 emission. In order to establish the best basis for upgrading the energy performance, it is important to make measurements of the heat losses at different places on a building facade, in order...

  4. Hawaiian direct-heat grants encourage geothermal creativity

    Beck, A.G. (Dept. of Business and Economic Development, Hilo, HI (USA))


    The Hawaiian Community Geothermal Technology Program is unique. Under its auspices, heat and other by-products of Hawaii's high-temperature HGP-A geothermal well and power plant are not wasted. Instead, they form the backbone of a direct-heat grant program that reaches into the local community and encourages community members to develop creative uses for geothermal energy. A by-product of this approach is a broadened local base of support for geothermal energy development. With the experimental and precommercial work completed, most of the original grantees are looking for ways to continue their projects on a commercial scale by studying the economics of using geothermal heat in a full-scale business and researching potential markets. A geothermal mini-park may be built near the research center. In 1988, a second round of projects was funded under the program. The five new projects are: Geothermal Aquaculture Project - an experiment with low-cost propagation of catfish species in geothermally heated tanks with a biofilter; Media Steam Sterilization and Drying - an application of raw geothermal steam to shredded, locally-available materials such as coconut husks, which would be used as certified nursery growing media; Bottom-Heating System Using Geothermal Power for Propagation - a continuation of Leilani Foliage's project from the first round of grants, focusing on new species of ornamental palms; Silica Bronze - the use of geothermal silica as a refractory material in casting bronze artwork; and Electro-deposition of Minerals in Geothermal Brine - the nature and possible utility of minerals deposited from the hot fluid.

  5. Municipal geothermal heat utilization plan for Glenwood Springs, Colorado


    A study has been made of the engineering and economic feasibility of utilizing the geothermal resource underlying Glenwood Springs Colorado, to heat a group of public buildings. The results have shown that the use of geothermal heat is indeed feasible when compared to the cost of natural gas. The proposed system is composed of a wellhead plate heat exchanger which feeds a closed distribution loop of treated water circulated to the buildings which form the load. The base case system was designed to supply twice the demand created by the seven public buildings in order to take advantage of some economies of scale. To increase the utilization factor of the available geothermal energy, a peaking boiler which burns natural gas is recommended. Disposal of the cooled brine would be via underground injection. Considerable study was done to examine the impact of reduced operating temperature on the existing heating systems. Several options to minimize this problem were identified. Economic analyses were completed to determine the present values of heat from the geothermal system and from the present natural gas over a 30 year projected system life. For the base case savings of over $1 million were shown. Sensitivities of the economics to capital cost, operating cost, system size and other parameters were calculated. For all reasonable assumptions, the geothermal system was cheaper. Financing alternatives were also examined. An extensive survey of all existing data on the geology of the study has led to the prediction of resource parameters. The wellhead temperature of produced fluid is suspected to lie between 140 and 180/sup 0/F (60 and 82/sup 0/C). Flowrates may be as high as 1000 gpm (3800 liters per minute) from a reservoir formation that is 300 ft (90 m) thick beginning about 500 ft (150 m) below the suggested drill site in the proposed Two Rivers Park.

  6. Low Temperature Heat Source Utilization Current and Advanced Technology

    Anderson, James H. Jr.; Dambly, Benjamin W.


    Once a geothermal heat source has been identified as having the potential for development, and its thermal, physical, and chemical characteristics have been determined, a method of utilization must be decided upon. This compendium will touch upon some of these concerns, and hopefully will provide the reader with a better understanding of technologies being developed that will be applicable to geothermal development in East Africa, as well as other parts of the world. The appendices contain detailed reports on Down-the-Well Turbo Pump, The Vapor-Turbine Cycle for Geothermal Power Generation, Heat Exchanger Design for Geothermal Power Plants, and a Feasibility Study of Combined Power and Water Desalting Plant Using Hot Geothermal Water. [DJE-2005

  7. TECHNICAL NOTE: A feasibility study of self-heating concrete utilizing carbon nanofiber heating elements

    Chang, Christiana; Ho, Michelle; Song, Gangbing; Mo, Yi-Lung; Li, Hui


    This paper presents the development of an electric, self-heating concrete system that uses embedded carbon nanofiber paper as electric resistance heating elements. The proposed system utilizes the conductive properties of carbon fiber materials to heat a surface overlay of concrete with various admixtures to improve the concrete's thermal conductivity. The development and laboratory scale testing of the system were conducted for the various compositions of concrete containing, separately, carbon fiber, fly ash, and steel shavings as admixtures. The heating performances of these concrete mixtures with the carbon fiber heating element were experimentally obtained in a sub-freezing ambient environment in order to explore the use of such a system for deicing of concrete roadways. Analysis of electric power consumption, heating rate, and obtainable concrete surface temperatures under typical power loads was performed to evaluate the viability of a large scale implementation of the proposed heating system for roadway deicing applications. A cost analysis is presented to provide a comparison with traditional deicing methods, such as salting, and other integrated concrete heating systems.

  8. High temperature polymer fuel cells. Heat utilization and co tolerance

    Jens, Oluf Jensen; Qingfeng, Li; Ronghuan, He; Gang, Xiao; Ji-An, Gao; Bjerrum, N.J. [Denmark Technical Univ., Department of Chemistry, Lyngby (Denmark)


    This paper will report recent results from our group on polymer fuel cells (PEMFC) based on the temperature resistant polymer poly-benzimidazole (PBI), which allow working temperatures up to 200 C. The membrane has a water drag number near zero and need no water management at all. The high working temperature allows for utilization of the excess heat for fuel processing. Moreover, it provides an excellent CO tolerance of several percent, and the system needs no purification of hydrogen from a reformer. Continuous service for over 6 months at 150 C has been demonstrated. (authors)

  9. Estimation of low-potential heat recuperation efficiency of smoke fumes in a condensation heat utilizer under various operation conditions of a boiler and a heating system

    Ionkin, I. L.; Ragutkin, A. V.; Luning, B.; Zaichenko, M. N.


    For enhancement of the natural gas utilization efficiency in boilers, condensation heat utilizers of low-potential heat, which are constructed based on a contact heat exchanger, can be applied. A schematic of the contact heat exchanger with a humidifier for preheating and humidifying of air supplied in the boiler for combustion is given. Additional low-potential heat in this scheme is utilized for heating of the return delivery water supplied from a heating system. Preheating and humidifying of air supplied for combustion make it possible to use the condensation utilizer for heating of a heat-transfer agent to temperature exceeding the dewpoint temperature of water vapors contained in combustion products. The decision to mount the condensation heat utilizer on the boiler was taken based on the preliminary estimation of the additionally obtained heat. The operation efficiency of the condensation heat utilizer is determined by its structure and operation conditions of the boiler and the heating system. The software was developed for the thermal design of the condensation heat utilizer equipped by the humidifier. Computation investigations of its operation are carried out as a function of various operation parameters of the boiler and the heating system (temperature of the return delivery water and smoke fumes, air excess, air temperature at the inlet and outlet of the condensation heat utilizer, heating and humidifying of air in the humidifier, and portion of the circulating water). The heat recuperation efficiency is estimated for various operation conditions of the boiler and the condensation heat utilizer. Recommendations on the most effective application of the condensation heat utilizer are developed.

  10. System for vaporizing carbon dioxide utilizing the heat by-product of the refrigeration system as a heat source

    Shaw, H.L.


    The present invention is directed to a carbonation and refrigeration system wherein the heat of the refrigerant output side of the refrigeration compressor is utilized to vaporize liquid carbon dioxide into CO/sub 2/ gas which is introduced into a liquid product. The carbonation and refrigeration system successfully utilizes the heat of the refrigerant to vaporize the CO/sub 2/ liquid regardless of the cooling demand of the system caused by seasonal temperature variations. For example during the winter months when the cooling demand is as low as 10% of the cooling demand in the summer, the carbonation and refrigeration system operates effectively to vaporize the CO/sub 2/ liquid by means of a heat exchanger and a desuperheater which are connected in communication with the superheated vapor emerging from the output side of a refrigeration compressor. In addition, the carbonation and refrigeration system of the present invention cools more efficiently by extracting some of the heat from the condensed refrigerant entering the receiver of the refrigeration system. In this manner, the refrigeration compressor can operate more efficiently.

  11. Significant utilization of heat from biogas; Waerme aus Biogas sinnvoll nutzen

    Schulz, W. [Bremer Energie-Institut, Bremen (Germany)


    Agricultural biogas facilities often are developed at remote locations. The sales potentials for the heat produced thereby are insufficient. Under this aspect, the author of the contribution under consideration reports on options for the improvement of the utilization of the available heat. The author describes the requirement profile for these options of utilization. Subsequently, ten options for utilization of heat as well as the appropriate details of application are described. In particular the following options of utilization are specified: drying plants, heating of hothouses, aquacultures, transport of latent heat, refrigeration, thermal processing of remainders of fermentation, supply of heat for laundries, production of fruit juice and vegetable juice, refinement of milk.

  12. Directional heat transport through thermal reflection meta-device

    Hu, Run; Zhou, Shuling; Shu, Weicheng; Xie, Bin; Ma, Yupu; Luo, Xiaobing


    Directional heat transfer may be hard to realize due to the fact that heat transfer is diffusive. In this paper, we try to take one step forward based on the transformation thermodynamics. A special structure and meta-device is proposed to "reflect" the heat flow directionally-just like the mirror to the light beam, in which the heat flow just one-time changes the direction rather than gradually changing the directions in isotropic materials. The benefits of such thermal reflection meta-device are discussed by comparing the corresponding thermal resistance with the same structures of isotropic materials. The proposed meta-device is verified to possess the low thermal resistance and high heat transfer ability with least energy loss, and can be made by nature-existing isotropic materials with specific structures.


    Victor Demidovich


    Full Text Available Continuous Hot-Dip Galvanizing lines are widely used for the production of coated steel sheets. Quality improvement measures are of great importance for this type of line. A significant proportion of production and quality losses when operating these types of lines occurs when production is transitioning from one strip gauge/thermal cycle to another. Utilizing induction heating technology, in combination with a sophisticated control system, can dramically decrease yield losses during transitions. Dynamic Transition and Production Planning Models have recently been developed for the simulation and control of the continuous hot-dip galvanizing line. The results of this work have been implemented in some galvanizing lines with production rate up to 350,000-ton annual capacity.

  14. Utilization of waste heat in trucks for increased fuel economy

    Leising, C. J.; Purohit, G. P.; Degrey, S. P.; Finegold, J. G.


    The waste heat utilization concepts include preheating, regeneration, turbocharging, turbocompounding, and Rankine engine compounding. Predictions are based on fuel-air cycle analyses, computer simulation, and engine test data. All options are evaluated in terms of maximum theoretical improvements, but the Diesel and adiabatic Diesel are also compared on the basis of maximum expected improvement and expected improvement over a driving cycle. The study indicates that Diesels should be turbocharged and aftercooled to the maximum possible level. The results reveal that Diesel driving cycle performance can be increased by 20% through increased turbocharging, turbocompounding, and Rankine engine compounding. The Rankine engine compounding provides about three times as much improvement as turbocompounding but also costs about three times as much. Performance for either can be approximately doubled if applied to an adiabatic Diesel.

  15. Utilization of geothermal heat in tropical fruit-drying process

    Chen, B.H.; Lopez, L.P.; King, R.; Fujii, J.; Tanaka, M.


    The power plant utilizes only the steam portion of the HGP-A well production. There are approximately 50,000 pounds per hour of 360/sup 0/F water produced (approximately 10 million Btu per hour) and the water is currently not used and is considered a waste. This tremendous resource could very well be used in applications such as food processing, food dehydration and other industrial processing that requires low-grade heat. One of the applications is examined, namely the drying of tropical fruits particularly the papaya. The papaya was chosen for the obvious reason that it is the biggest crop of all fruits produced on the Big Island. A conceptual design of a pilot plant facility capable of processing 1000 pounds of raw papaya per day is included. This facility is designed to provide a geothermally heated dryer to dehydrate papayas or other tropical fruits available on an experimental basis to obtain data such as drying time, optimum drying temperature, etc.

  16. Direct contact droplet heat exchangers for thermal management in space

    Bruckner, A. P.; Hertzberg, A.


    A liquid droplet heat exchanger for space applications is described which transfers heat between a gas and a liquid metal dispersed into droplets. The ability of the droplet heat exchanger to transfer heat between two media in direct contact over a wide temperature range circumvents many of the material limitations of conventional tube-type heat exchangers and does away with complicated plumbing systems and their tendency toward single point failure. Droplet heat exchangers offer large surface to volume ratios in a compact geometry, very low gas pressure drop, and high effectiveness. The application of the droplet heat exchanger in a high temperature Brayton cycle is discussed to illustrate its performance and operational characteristics.

  17. Influence of Compressor Station Waste-Heat Recovery Section on Operational Efficiency of Gas Turbine Drive with Isobaric Heat Supply and Regenerative Heat Utilization

    A. Nesenchuk


    Full Text Available The possibility to utilize existing secondary energy resources for heat supply of an industrial enterprise has been proposed on the basis of the analysis on operation of compressor stations of a cross-country gas pipe-line. The paper considers an influence of waste heat recovery section on operational efficiency of gas turbine drive with regenerative heat utilization.

  18. Investigation of direct expansion in ground source heat pumps

    Kalman, M. D.

    A fully instrumented subscale ground coupled heat pump system was developed, and built, and used to test and obtain data on three different earth heat exchanger configurations under heating conditions (ground cooling). Various refrigerant flow control and compressor protection devices were tested for their applicability to the direct expansion system. Undistributed Earth temperature data were acquired at various depths. The problem of oil return at low evaporator temperatures and low refrigerant velocities was addressed. An analysis was performed to theoretically determine what evaporator temperature can be expected with an isolated ground pipe configuration with given length, pipe size, soil conditions and constant heat load. Technical accomplishments to data are summarized.

  19. Absorption type water chiller fired directly by waste heat

    Sauer, K. L.; Kalwar, K.


    The direct use of waste heat as heating element in a water chiller of the absorption type was studied. The chilled water is used as cooling element in the industrial process, producing the waste heat or for conditioning the workplace or further located places. The heat source is gaseous or liquid. The cooling capacity is in the range from 10 to 120 kW. After reviewing the different absorption systems, LiBr/H20 proved to be the most suitable. The process retained for experimenting was the manufacturing of synthetic materials polymer industry and was tested in two different factories. It is proved that the use of absorption type water chillers is practicable with an efficiency of 10% to 25% of the waste heat energy, but that the existing chillers need extensive conversion for obtaining economical operation when using a low temperature heating source.

  20. Utilization of waste heat from energy conversion and industrial processes

    Evans, A.R.; Hamilton, R.W.

    The laws of thermodynamics state that no process of energy transformation can take place with perfect efficiency--some waste heat is always produced. The generation of waste heat from energy conversion and industrial processes are discussed. First-law and second-law efficiencies are defined. After listing the amounts of waste heat produced, some technological options for reducing waste heat or using it for other purposes, such as district heating, are described.

  1. Research and development of a 3 MW power plant from the design, development, and demonstration of a 100 KW power system utilizing the direct contact heat exchanger concept for geothermal brine recovery project

    Huebner, A. W.; Wall, D. A.; Herlacher, T. L.


    The design phase for the 100 KW unit consumed the months of May through November 1978, with the final design having a direct contact boiler and condenser, a single-stage radial inflow induction turbine generator using isopentane as the working fluid, and a single cell ejector-type cooling tower. The unit was constructed on two, forty-foot flatbed trailers between the months of October 1978 and June 1979. Systems start-up testing, in-field modifications, unit operation, and performance testing were performed between July and December 1979. AP and L (Arkansas Power and Light) personnel assumed responsibility of the unit at that time and conducted further maintenance, operations, and testing through August 1980.

  2. Enhancing nursing practice by utilizing voice recognition for direct documentation.

    Fratzke, Jason; Tucker, Sharon; Shedenhelm, Heidi; Arnold, Jackie; Belda, Tom; Petera, Michael


    Innovative strategies that preserve nursing time for direct patient care activities are needed. This study examined the utility, feasibility, and acceptability of voice recognition (VR) software to document nursing care and patient outcomes in an electronic health record in a simulated nursing care environment. A phase 1 trial included 5 iterative experiments with observations and nurse participant feedback to allow enhancements to the speech detection capabilities and refinement of the technology, software, and processes. Utility ratings improved over time; however, interference on nursing care remained a concern throughout. Nurse participants favored keyboard entry electronic health record, largely due to software and technical issues, but also relative to the culture shift the new technology brings to nursing practice. Successful adoption of VR technology by nursing will be dependent on receptiveness of the nurses and perceived benefits, timely access to education and training, and minimization of barriers to using the software.

  3. Gradient utilization of coking waste heat%焦化余热的梯级利用

    徐营营; 刘旭明; 赵永宽


    利用焦化生产过程中的余热进行冬季采暖,可将采暖后的余热供蔬菜大棚利用,再回收低品质热能,实现热量梯级利用。%This paper presents the method of utilizing the coking waste heat for winter heating, and the waste heat after winter heating is further supplied to vegetable greenhouse, which has recovered low quality heat energy and realized gradient utilization of heat energy.

  4. Experimental performance of a waste heat recovery and utilization system with a looped water-in-steel heat pipe

    Habeebullah, M.H.; Akyurt, M.; Najjar, Y.S.H.; El-Kalay, A.K. [King Abdulaziz Univ., Jeddah (Saudi Arabia). College of Engineering


    An experimental facility is described for the recovery, by means of heat-pipes, of waste-heat from exhaust gases, and the utilization of the recovered energy to cool ambient air. To this end, heat of combustion gases, generated in a stainless-steel combustion chamber, is recovered from the stack by means of a heat-pipe system. The recovered heat is utilized to run a modified commercial aqua-ammonia absorption chiller. Chilled water from the chiller is supplied to a fan-coil type cooling tunnel to cool the intake air of a (conceptual) gas turbine engine to boost its performance. It is concluded from test results that the experimental facility performs well, and that it behaves as predicted by modeling and simulation studies. The system is able to extract between 70 and 93% of the technically recoverable energy from exhaust gases, and utilizes the extracted energy to cool air. (Author)

  5. Present status of the solar heating utilization; Panorama atual da utilizacao de aquecimento solar

    Mesquita, Lucio Cesar Souza [Associacao Brasileira de Refrigeracao, Ar Condicionado, Ventilacao e Aquecimento (ABRAVA), Rio de Janeiro, RJ (Brazil). Dept. de Aquecimento Solar


    This paper presents the status of the solar heating utilization in Brazil. The paper consider the subjects as follows: general aspects of solar heating, systems re dimensioning, collectors, thermal reservoirs,systems installation, large scale systems, hydraulics and hot water utilization, and maintenance.


    A. N. Kuzovlev


    Full Text Available The paper considers a possibility  to use a  thermal pump and heat-exchange device  in  the ventilation system  for heat utilization of exhaust air. An  influence of air characteristics on  energy  efficiency  of heat-utilizing installations has been shown in the paper. Specific feature of the thermal pump application is the fact hat a source of secondary heat has higher temperature than a consumer. The paper contains results of thermal pump and heat exchange device parameters, hat characterize their efficiency while being applied in a ventilation system.

  7. Direct electronic measurement of Peltier cooling and heating in graphene

    Vera-Marun, I. J.; van den Berg, J. J.; Dejene, F. K.; van Wees, B. J.


    Thermoelectric effects allow the generation of electrical power from waste heat and the electrical control of cooling and heating. Remarkably, these effects are also highly sensitive to the asymmetry in the density of states around the Fermi energy and can therefore be exploited as probes of distortions in the electronic structure at the nanoscale. Here we consider two-dimensional graphene as an excellent nanoscale carbon material for exploring the interaction between electronic and thermal transport phenomena, by presenting a direct and quantitative measurement of the Peltier component to electronic cooling and heating in graphene. Thanks to an architecture including nanoscale thermometers, we detected Peltier component modulation of up to 15 mK for currents of 20 μA at room temperature and observed a full reversal between Peltier cooling and heating for electron and hole regimes. This fundamental thermodynamic property is a complementary tool for the study of nanoscale thermoelectric transport in two-dimensional materials.

  8. Decontamination of drinking water by direct heating in solar panels.

    Fjendbo Jørgensen, A J; Nøhr, K; Sørensen, H; Boisen, F


    A device was developed for direct heating of water by solar radiation in a flow-through system of copper pipes. An adjustable thermostat valve prevents water below the chosen temperature from being withdrawn. The results show that it is possible to eliminate coliform and thermotolerant coliform bacteria from naturally contaminated river water by heating to temperatures of 65 degrees C or above. Artificial additions of Salmonella typhimurium, Streptococcus faecalis and Escherichia coli to contaminated river water were also inactivated after heating to 65 degrees C and above. The total viable count could be reduced by a factor of 1000. The heat-resistant bacteria isolated from the Mlalakuva River (Tanzania) were spore-forming bacteria which exhibited greater heat resistance than commonly used test bacteria originating from countries with colder climates. To provide a good safety margin it is recommended that an outlet water temperature of 75 degrees C be used. At that temperature the daily production was about 501 of decontaminated water per m2 of solar panel, an amount that could be doubled by using a heat exchanger to recycle the heat.

  9. Industrial applications study. Volume II. Industrial data base. Final report. [Waste heat recovery and utilization

    Brown, Harry L.; Hamel, Bernard B.; Karamchetty, Som; Steigelmann, William H.; Gajanana, Birur C.; Agarwal, Anil P.; Klock, Lawrence W.; Henderson, James M.; Calobrisi, Gary; Hedman, Bruce A.; Koluch, Michael; Biancardi, Frank; Bass, Robert; Landerman, Abraham; Peters, George; Limaye, Dilip; Price, Jeffrey; Farr, Janet


    An initial evaluation of the waste heat recovery and utilization potential in the manufacturing portion of the industrial sector is presented. The scope of this initial phase addressed the feasibility of obtaining in-depth energy information in the industrial sector. Within this phase, the methodology and approaches for data gathering and assessment were established. Using these approaches, energy use and waste heat profiles were developed at the 2-digit level; with this data, waste heat utilization technologies were evaluated.

  10. Direct utilization of geothermal energy in the Peoples Republic of China

    Lund, J. W.


    A brief review of the direct utilization of geothermal energy in three regions of the Peoples' Republic of China is presented, stressing a development outline for the next five to ten years. The geothermal resource of the Tianjin-Beijing area is mainly to be developed for space heating, whereas along the coastal area of Fujian and Guangdong, it will be developed for agriculture, and industrial and residential use. Electric power generation will be the main concern in the southwest at Tengchong. Most theoretical research will be done on geologic structure interpretation, corrosion of pump shafts and buried pipelines, and heat flow, with some interest in the study of geopressure and hot dry rock systems. Specific examples from the Tianjin area include a wool factory; a wool rug weaving shop; heating of a hotel; public bathing; and well drilling for apartment heating, fish breeding, and greenhouses. Direct use of geothermal energy in the Beijing area includes cotton dyeing, humidifying, medical purposes, and animal husbandry. Experimental geothermal electric power plants are summarized in table form.

  11. Research on Microwave Heating-Direct Steelmaking in Electric Furnace

    CHEN Jin; LIU Liu; ZENG Jia-qing; REN Rui-gang; LIU Jin-ying


    Self-fluxing iron ore concentrates containing coal have good microwave absorbability.With the voluminal heating property of microwave,the concentrates can be reduced uniformly and swiftly.The metallized semi-product can be directly charged into electric furnace for making clean steel.The total consumed energy of overall route is about 20.98 GJ.

  12. Enhanced methanol utilization in direct methanol fuel cell

    Ren, Xiaoming; Gottesfeld, Shimshon


    The fuel utilization of a direct methanol fuel cell is enhanced for improved cell efficiency. Distribution plates at the anode and cathode of the fuel cell are configured to distribute reactants vertically and laterally uniformly over a catalyzed membrane surface of the fuel cell. A conductive sheet between the anode distribution plate and the anodic membrane surface forms a mass transport barrier to the methanol fuel that is large relative to a mass transport barrier for a gaseous hydrogen fuel cell. In a preferred embodiment, the distribution plate is a perforated corrugated sheet. The mass transport barrier may be conveniently increased by increasing the thickness of an anode conductive sheet adjacent the membrane surface of the fuel cell.

  13. Utilization of Additive Manufacturing for Aerospace Heat Exchangers


    A Game Changer for the Manufacturing Industry?" Nov. 2013. Web. < media /pdf...hub/Advantages-and-Disadvantages-of-Shell-and- T ube-Piate-type-Heat -Exchangers>. " Arithmetic and Logarithmic Mean Temperature Difference...34 Arithmetic and Logarithmic Mean Temperature Difference. The Engineering Toolbox. Web. 28 July 2014. "Benefits Of Using A Flat Plate Heat Exchanger

  14. An Efficient Heat Exchanger for In Situ Resource Utilization Project

    National Aeronautics and Space Administration — In situ resource utilization (ISRU) is essential for several of NASA's future flagship missions. Currently envisioned ISRU plants include production of oxygen from...

  15. Direct heat applications of geothermal energy in The Geysers/Clear Lake region. Volume I. Geotechnical assessment, agribusiness applications, socioeconomic assessment, engineering assessment. Final report


    The different uses to which geothermal heat and fluids could be applied as a direct utilization of resource or as heat utilization are explored. The following aspects are covered: geotechnical assessment, agricultural and industrial applications, socioeconomic assessment, and engineering assessment. (MHR)

  16. Industrial applications study. Volume IV. Industrial plant surveys. Final report. [Waste heat recovery and utilization

    Brown, Harry L.; Hamel, Bernard B.; Karamchetty, Som; Steigelmann, William H.; Gajanana, Birur C.; Agarwal, Anil P.; Klock, Lawrence M.; Henderson, James M.; Calobrisi, Gary; Hedman, Bruce A.; Koluch, Michael; Biancardi, Frank; Bass, Robert; Landerman, Abraham; Peters, George; Limaye, Dilip; Price, Jeffrey; Farr, Janet


    An initial evaluation of the waste heat recovery and utilization potential in the manufacturing portion of the industrial sector is presented. The scope of this initial phase addressed the feasibility of obtaining in-depth energy information in the industrial sector. Within this phase, the methodology and approaches for data gathering and assessment were established. Using these approaches, energy use and waste heat profiles were developed at the 2-digit level; with this data, waste heat utilization technologies were evaluated. This study represents an important first step in the evaluation of waste heat recovery potential.

  17. Advanced radiator concepts utilizing honeycomb panel heat pipes (stainless steel)

    Fleischman, G. L.; Tanzer, H. J.


    The feasibility of fabricating and processing moderate temperature range heat pipes in a low mass honeycomb sandwich panel configuration for highly efficient radiator fins for the NASA space station was investigated. A variety of honeycomb panel facesheet and core-ribbon wick concepts were evaluated within constraints dictated by existing manufacturing technology and equipment. Concepts evaluated include: type of material, material and panel thicknesses, wick type and manufacturability, liquid and vapor communication among honeycomb cells, and liquid flow return from condenser to evaporator facesheet areas. In addition, the overall performance of the honeycomb panel heat pipe was evaluated analytically.

  18. Direct utilization of geothermal energy for Pagosa Springs, Colorado. Final report, June 1979-June 1984

    Goering, S.W.; Garing, K.L.; Coury, G.


    The Pagosa Springs Geothermal District Heating System was conceptualized, designed, and constructed between 1979 to 1984 under the US Department of Energy Program Opportunity Notice (PON) program to demonstrate the feasibility for utilizing moderate temperature geothermal resources for direct-use applications. The Pagosa Springs system successfully provides space heating to public buildings, school facilities, residences, and commercial establishments at costs significantly lower than costs of available conventional fuels. The Pagosa Springs project encompassed a full range of technical, institutional, and economic activities. Geothermal reservoir evaluations and testing were performed, and two productive approx.140/sup 0/F geothermal supply wells were successfully drilled and completed. Transmission and distribution system design, construction, startup, and operation were achieved with minimum difficulty. The geothermal system operation during the first two heating seasons has been fully reliable and well respected in the community. The project has proven that low to moderate-temperature waters can effectively meet required heating loads, even for harsh winter-mountain environments. The principal difficulty encountered has been institutional in nature and centers on the obtaining of the geothermal production well permits and the adjudicated water rights necessary to supply the geothermal hot water fluids for the full operating life of the system. 28 figs., 15 tabs.

  19. Test results of a Stirling engine utilizing heat exchanger modules with an integral heat pipe

    Skupinski, Robert C.; Tower, Leonard K.; Madi, Frank J.; Brusk, Kevin D.


    The Heat Pipe Stirling Engine (HP-1000), a free-piston Stirling engine incorporating three heat exchanger modules, each having a sodium filled heat pipe, has been tested at the NASA-Lewis Research Center as part of the Civil Space Technology Initiative (CSTI). The heat exchanger modules were designed to reduce the number of potential flow leak paths in the heat exchanger assembly and incorporate a heat pipe as the link between the heat source and the engine. An existing RE-1000 free-piston Stirling engine was modified to operate using the heat exchanger modules. This paper describes heat exchanger module and engine performance during baseline testing. Condenser temperature profiles, brake power, and efficiency are presented and discussed.

  20. Direct contact liquid-liquid heat exchanger for solar heated and cooled buildings

    Karaki, S.; Brothers, P.


    The technical and economic feasibility of using a direct contract liquid-liquid heat exchanger (DCLLHE) storage unit in a solar heating and cooling system is established. Experimental performance data were obtained from the CSU Solar House I using a DCLLHE for both heating and cooling functions. A simulation model for the system was developed. The model was validated using the experimental data and applied in five different climatic regions of the country for a complete year. The life-cycle cost of the system was estimated for each application. The results are compared to a conventional solar system, using a standard shell-and-tube heat exchanger. It is concluded that while there is a performance advantage with a DCLLHE system over a conventional solar system, the advantage is not sufficiently large to overcome slightly higher capital and operating costs for the DCLLHE system.

  1. Thermal performance of direct contact heat exchangers for mixed hydrocarbons

    Sharpe, L. Jr.; Coswami, D.Y.; Demuth, O.J.; Mines, G.


    This paper describes a physical and a mathematical model for evaluating the tray efficiencies for a direct contact heat exchanger (DCHX). The model is then used to determine the efficiencies for tests conducted on a 60kW sieve tray DCHX as heat is transferred from a geofluid (brine) to a working fluid (mixed hydrocarbons). It is assumed that there are three distinct regions in the column based on the state of the working fluid, as follows: Region I - Preheating with no vaporization; Region II - Preheating with moderate vaporization; and Region III - Major vaporization. The boundaries of these regions can be determined from the experimental data. In the model, mass balance and energy balance is written for a tray ''N'' in each of these regions. Finally, the ''tray efficiency'' or ''heat transfer'' effectiveness of the tray is calculated based on the definition that it is the ratio of the actual heat transfer to the maximum possible, thermodynamically.

  2. Direct containment heating models in the CONTAIN code

    Washington, K.E.; Williams, D.C.


    The potential exists in a nuclear reactor core melt severe accident for molten core debris to be dispersed under high pressure into the containment building. If this occurs, the set of phenomena that result in the transfer of energy to the containment atmosphere and its surroundings is referred to as direct containment heating (DCH). Because of the potential for DCH to lead to early containment failure, the U.S. Nuclear Regulatory Commission (USNRC) has sponsored an extensive research program consisting of experimental, analytical, and risk integration components. An important element of the analytical research has been the development and assessment of direct containment heating models in the CONTAIN code. This report documents the DCH models in the CONTAIN code. DCH models in CONTAIN for representing debris transport, trapping, chemical reactions, and heat transfer from debris to the containment atmosphere and surroundings are described. The descriptions include the governing equations and input instructions in CONTAIN unique to performing DCH calculations. Modifications made to the combustion models in CONTAIN for representing the combustion of DCH-produced and pre-existing hydrogen under DCH conditions are also described. Input table options for representing the discharge of debris from the RPV and the entrainment phase of the DCH process are also described. A sample calculation is presented to demonstrate the functionality of the models. The results show that reasonable behavior is obtained when the models are used to predict the sixth Zion geometry integral effects test at 1/10th scale.

  3. Cascaded organic rankine cycles for waste heat utilization

    Radcliff, Thomas D.; Biederman, Bruce P.; Brasz, Joost J.


    A pair of organic Rankine cycle systems (20, 25) are combined and their respective organic working fluids are chosen such that the organic working fluid of the first organic Rankine cycle is condensed at a condensation temperature that is well above the boiling point of the organic working fluid of the second organic Rankine style system, and a single common heat exchanger (23) is used for both the condenser of the first organic Rankine cycle system and the evaporator of the second organic Rankine cycle system. A preferred organic working fluid of the first system is toluene and that of the second organic working fluid is R245fa.

  4. Automotive absorption air conditioner utilizing solar and motor waste heat

    Popinski, Z. (Inventor)


    In combination with the ground vehicles powered by a waste heat generating electric motor, a cooling system including a generator for driving off refrigerant vapor from a strong refrigerant absorbant solution is described. A solar collector, an air-cooled condenser connected with the generator for converting the refrigerant vapor to its liquid state, an air cooled evaporator connected with the condenser for returning the liquid refrigerant to its vapor state, and an absorber is connected to the generator and to the evaporator for dissolving the refrigerant vapor in the weak refrigerant absorbant solution, for providing a strong refrigerant solution. A pump is used to establish a pressurized flow of strong refrigerant absorbant solution from the absorber through the electric motor, and to the collector.

  5. Direct utilization of geothermal energy in western South Dakota agribusiness. Final report

    Howard, S.M.


    This project involved the direct utilization of geothermal energy for (1) space heating of farm and ranch buildings, (2) drying grain, and (3) providing warm stock water during the winter. The site for this demonstration project was the Diamond Ring Ranch north of Midland, South Dakota. Geothermal water flowing from an existing well into the Madison Aquifer was used to heat four homes, a shop, a hospital barn for cattle, and air for a barn and grain dryer. This site is centrally located in the western region of South Dakota where geothermal water is available from the Madison Aquifer. The first year of the project involved the design of the heating systems and its construction while the following years were for operation, testing, demonstrating, and monitoring the system. Required modifications and improvements were made during this period. Operating modifications and improvements were made during this period. Operating experience showed that such application of geothermal resources is feasible and can result in substantial fuel savings. Economic analyses under a variety of assumptions generally gave payback periods of less than ten years. Numerous technical recommendations are made. The most significant being the necessity of passive protection from freezing of remote geothermal systems subject to winter shut downs caused by power or equipment failure. The primary institutional recommendation is to incorporate a use for the geothermal water such as irrigation or stock watering into agribusiness-related geothermal development.

  6. EAF Gas Waste Heat Utilization and Discussion of the Energy Conservation and CO2 Emissions Reduction

    Yang, Ling-zhi; Zhu, Rong; Ma, Guo-hong


    As a large number of energy was taken away by the high temperature furnace gas during the EAF smelting process, a huge economic and environmental benefits would obtained to recycle and utilize. In this paper, the energy of the EAF was analyzed theoretically with the hot metal ratio of 50%. Combined with the utilization of the gas waste heat during the scrap preheating, electricity generation, production of steam and production of coal gas processes, the effect of the energy saving and emission was calculated with comprehensive utilization of the high temperature furnace gas. An optimal scheme for utilization of the waste heat was proposed based on the calculation. The results show that the best way for energy saving and carbon reduction is the production of coal gas, while the optimal scheme for waste heat utilization is combined the production of coal gas with the scrap preheating, which will save 170 kWh/t of energy and decrease 57.88 kg/t of carbon emission. As hot metal ratio in EAF steelmaking is often more than 50%, which will produce more EAF gas waste heat, optimizing EAF gas waste heat utilization will have more obvious effect on energy saving and emission reduction.

  7. The effect of heating direction on flow boiling heat transfer of R134a in micro-channels

    Xu, Mingchen; Jia, Li; Dang, Chao; Peng, Qi


    This paper presents effects of heating directions on heat transfer performance of R134a flow boiling in micro- channel heat sink. The heat sink has 30 parallel rectangular channels with cross-sectional dimensions of 500μm width 500μm depth and 30mm length. The experimental operation condition ranges of the heat flux and the mass flux were 13.48 to 82.25 W/cm2 and 373.3 to 1244.4 kg/m2s respectively. The vapor quality ranged from 0.07 to 0.93. The heat transfer coefficients of top heating and bottom heating both were up to 25 kW/m2 K. Two dominate transfer mechanisms of nucleate boiling and convection boiling were observed according to boiling curves. The experimental results indicated that the heat transfer coefficient of bottom heating was 13.9% higher than top heating in low heat flux, while in high heat flux, the heat transfer coefficient of bottom heating was 9.9%.higher than the top heating, because bubbles were harder to divorce the heating wall. And a modified correlation was provided to predict heat transfer of top heating.

  8. Direct Carbon Fuel Cell System Utilizing Solid Carbonaceous Fuels

    Turgut Gur


    This 1-year project has achieved most of its objective and successfully demonstrated the viability of the fluidized bed direct carbon fuel cell (FB-DCFC) approach under development by Direct Carbon technologies, LLC, that utilizes solid carbonaceous fuels for power generation. This unique electrochemical technology offers high conversion efficiencies, produces proportionately less CO{sub 2} in capture-ready form, and does not consume or require water for gasification. FB-DCFC employs a specialized solid oxide fuel cell (SOFC) arrangement coupled to a Boudouard gasifier where the solid fuel particles are fluidized and reacted by the anode recycle gas CO{sub 2}. The resulting CO is electrochemically oxidized at the anode. Anode supported SOFC structures employed a porous Ni cermet anode layer, a dense yttria stabilized zirconia membrane, and a mixed conducting porous perovskite cathode film. Several kinds of untreated solid fuels (carbon and coal) were tested in bench scale FBDCFC prototypes for electrochemical performance and stability testing. Single cells of tubular geometry with active areas up to 24 cm{sup 2} were fabricated. The cells achieved high power densities up to 450 mW/cm{sup 2} at 850 C using a low sulfur Alaska coal char. This represents the highest power density reported in the open literature for coal based DCFC. Similarly, power densities up to 175 mW/cm{sup 2} at 850 C were demonstrated with carbon. Electrical conversion efficiencies for coal char were experimentally determined to be 48%. Long-term stability of cell performance was measured under galvanostatic conditions for 375 hours in CO with no degradation whatsoever, indicating that carbon deposition (or coking) does not pose any problems. Similar cell stability results were obtained in coal char tested for 24 hours under galvanostatic conditions with no sign of sulfur poisoning. Moreover, a 50-cell planar stack targeted for 1 kW output was fabricated and tested in 95% CO (balance CO{sub 2

  9. Performance of ultra low temperature district heating systems with utility plant and booster heat pumps

    Ommen, Torben Schmidt; Thorsen, Jan Eric; Markussen, Wiebke Brix


    and power (CHP) and central heat pumps (HPs). The analysis focussed on the characteristic heat demands of newly build multi-story buildings and the results were based on the ratio of the individual demands compared to the total. It was found that the optimal return temperature was dependent on the forward...

  10. Performance prediction of an absorption heat pump for utilization in industry

    Lazzarin, R.M.; Longo, G.A. (Padua Univ. (Italy))


    Recently, an absorption heat pump has been put on the market for industrial utilization. It is a H[sub 2]O-LiBr absorption machine which heats up water to 90[sup o]C with cold source at 40[sup o]C. The capacity and Coefficient of performance (COP) of the machine have been studied by a computer program as a function of cold source temperature and heated fluid temperature. Also, a comparison with a compression heat pump is reported. (Author)

  11. Life expectancy impacts due to heating energy utilization in China: Distribution, relations, and policy implications.

    Wang, Shaobin; Luo, Kunli


    The relation between life expectancy and energy utilization is of particular concern. Different viewpoints concerned the health impacts of heating policy in China. However, it is still obscure that what kind of heating energy or what pattern of heating methods is the most related with the difference of life expectancies in China. The aim of this paper is to comprehensively investigate the spatial relations between life expectancy at birth (LEB) and different heating energy utilization in China by using spatial autocorrelation models including global spatial autocorrelation, local spatial autocorrelation and hot spot analysis. The results showed that: (1) Most of heating energy exhibit a distinct north-south difference, such as central heating supply, stalks and domestic coal. Whereas spatial distribution of domestic natural gas and electricity exhibited west-east differences. (2) Consumption of central heating, stalks and domestic coal show obvious spatial dependence. Whereas firewood, natural gas and electricity did not show significant spatial autocorrelation. It exhibited an extinct south-north difference of heat supply, stalks and domestic coal which were identified to show significant positive spatial autocorrelation. (3) Central heating, residential boilers and natural gas did not show any significant correlations with LEB. While, the utilization of domestic coal and biomass showed significant negative correlations with LEB, and household electricity shows positive correlations. The utilization of domestic coal in China showed a negative effect on LEB, rather than central heating. To improve the solid fuel stoves and control consumption of domestic coal consumption and other low quality solid fuel is imperative to improve the public health level in China in the future. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. Role of anthropogenic direct heat emissions in global warming

    Wang, Fei; Zhao, Guangju; Gao, Peng; Li, Pengfei


    The anthropogenic emissions of greenhouse gases (GHG) are widely realized as the predominant drivers of global warming, but the huge and increasing anthropogenic direct heat emissions (AHE) has not gained enough attention in terms of its role in the warming of the climate system. Based on two reasonable assumptions of (1) AHE eventually transfers to the Earth energy system and (2) the net warming is only driven by the net radioactive forcing (RF) from either GHG or other causes, we analyzed the role of AHE in global warming. The mean annual total AHE of the four main sources including energy consumption, residual heat of electricity generation, biomass decomposition by land use and cover change (LUCC) and food consumption was estimated to be 4.41*10^20 J in 1970-2010, accounting for 6.23% of the net annual heat increase of the Earth reported by IPCC AR5 for the period. The mean annual radioactive forcing (RF) by AHE was up to 29.94 mW m^(-2) globally in 1981-2010, less than the annual net increase of total GH...

  13. Analysis of a Residential Heating System Utilizing a Solar Assisted Water-to-Air Heat Pump.


    heat pump heating system were analyzed. A realistic residence and solar assisted water-to-air heat pump system were modeled for this northern climate using the transient simulation computer code TRNSYS developed by the University of Wisconsin. The system was studied over a one month winter period, December, using actual hourly weather data. The system was analyzed for both the cloudiest and clearest December weather recorded in the last 30 years. The collector area and storage tank capacity were varied and the effects on system performance were

  14. Utilization management in radiology, part 2: perspectives and future directions.

    Duszak, Richard; Berlin, Jonathan W


    Increased utilization of medical imaging in the early part of the last decade has resulted in numerous efforts to reduce associated spending. Recent initiatives have focused on managing utilization with radiology benefits managers and real-time order entry decision support systems. Although these approaches might seem mutually exclusive and their application to radiology appears unique, the historical convergence and broad acceptance of both programs within the pharmacy sector may offer parallels for their potential future in medical imaging. In this second installment of a two-part series, anticipated trends in radiology utilization management are reviewed. Perspectives on current and future potential roles of radiologists in such initiatives are discussed, particularly in light of emerging physician payment models. Copyright © 2012 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  15. Experimental investigations on cylindrical latent heat storage units with sodium acetate trihydrate composites utilizing supercooling

    Dannemand, Mark; Johansen, Jakob Berg; Kong, Weiqiang;


    unit was tested with 116.3 kg SAT with 0.5% Xanthan rubber as a thickening agent and 4.4% graphite powder. The heat exchange capacity rate during charge was significantly lower for the unit with SAT and Xanthan rubber compared to the unit with SAT and extra water. This was due to less convection......Latent heat storage units utilizing stable supercooling of sodium acetate trihydrate (SAT) composites were tested in a laboratory. The stainless steel units were 1.5 m high cylinders with internal heat exchangers of tubes with fins. One unit was tested with 116 kg SAT with 6% extra water. Another...... in the thickened phase change material after melting. The heat content in the fully charged state and the heat released after solidification of the supercooled SAT mixtures at ambient temperature was higher for the unit with the thickened SAT mixture. The heat discharged after solidification of the supercooled SAT...

  16. Study on improving efficiency in hydrogen utilizing regional heat supply system; Suiso riyo chinetsu kyokyu system no koritsu kaizen ni kansuru kenkyu

    Sueyoshi, S.; Ishitani, H.; Matsuhashi, T. [The University of Tokyo, Tokyo (Japan). Faculty of Engineering


    With an objective to improve efficiency in a hydrogen energy distribution system, discussions were given on combining heat energy supply from hydrogen with factory waste heat recovery by using hydrogen absorbing alloys. This system carries out simultaneously heat supply as a result of burning hydrogen directly and heat supply obtained by converting hydrogen pressure by using hydrogen absorbing alloys. This system could allow existing gas piping facilities to be utilized. However, since quantity of hydrogen that can be transported as pressure is smaller than quantity of heat of hydrogen itself, absorption and emission are repeated a number of times in order to utilize the heat source to a possible maximum extent. Thus, a large quantity of waste heat can be utilized when this method is used. A hydrogen manufacturing system by means of LNG reformation may be combined with this heat transportation system. When waste heat that is received is handled as having zero input in the same sense as natural energy, and heat supply from a hydrogen absorbing alloy is repeated for 50 times, the overall energy balance has resulted in a considerably good value at 0.95. 5 refs., 9 figs., 5 tabs.

  17. Advanced materials for alternative fuel capable directly fired heat engines

    Fairbanks, J.W.; Stringer, J. (eds.)


    The first conference on advanced materials for alternative fuel capable directly fired heat engines was held at the Maine Maritime Academy, Castine, Maine. It was sponsored by the US Department of Energy, (Assistant Secretary for Fossil Energy) and the Electric Power Research Institute, (Division of Fossil Fuel and Advanced Systems). Forty-four papers from the proceedings have been entered into EDB and ERA and one also into EAPA; three had been entered previously from other sources. The papers are concerned with US DOE research programs in this area, coal gasification, coal liquefaction, gas turbines, fluidized-bed combustion and the materials used in these processes or equipments. The materials papers involve alloys, ceramics, coatings, cladding, etc., and the fabrication and materials listing of such materials and studies involving corrosion, erosion, deposition, etc. (LTN)

  18. Design of plate directional heat transmission structure based on layered thermal metamaterials

    L. K. Sun


    Full Text Available Invisibility cloaks based on transformation optics are often closed structures; however, such a structure limits the kinds of objects that can be placed in the cloak. In this work, we adopt a transformation thermodynamics approach to design an “open cloak”, called a plate directional heat transmission structure, which is capable of guiding heat fluxes to the flank region of the metamaterial device. The most fascinating and unique feature of the device is that the lower surface can remain at a lower temperature compared with the SiO2 aerogel thermal insulation material. Our results are expected to markedly enhance capabilities in thermal protection, thermal-energy utilization, and domains beyond. In addition to the theoretical analysis, the present design is demonstrated in numerical simulations based on finite element calculations.

  19. Design of plate directional heat transmission structure based on layered thermal metamaterials

    Sun, L. K.; Yu, Z. F.; Huang, J., E-mail: [China Aerodynamics Research and Development Center, Mianyang 621000 (China)


    Invisibility cloaks based on transformation optics are often closed structures; however, such a structure limits the kinds of objects that can be placed in the cloak. In this work, we adopt a transformation thermodynamics approach to design an “open cloak”, called a plate directional heat transmission structure, which is capable of guiding heat fluxes to the flank region of the metamaterial device. The most fascinating and unique feature of the device is that the lower surface can remain at a lower temperature compared with the SiO{sub 2} aerogel thermal insulation material. Our results are expected to markedly enhance capabilities in thermal protection, thermal-energy utilization, and domains beyond. In addition to the theoretical analysis, the present design is demonstrated in numerical simulations based on finite element calculations.

  20. Modeling and simulation of combined gas turbine engine and heat pipe system for waste heat recovery and utilization

    Lamfon, N.J. [Saudi Aramco Jeddah Refinery, Jeddah (Saudi Arabia); Najjar, Y.S.H.; Akyurt, M. [King Abdulaziz Univ., Mechanical Engineering Dept., Jeddah (Saudi Arabia)


    The results of a modeling and simulation study are presented for a combined system consisting of a gas turbine engine, a heat pipe recovery system and an inlet-air cooling system. The presentation covers performance data related to the gas turbine engine with precooled air intake as coupled to the water-in-copper heat pipe recovery system. This is done by matching the two mathematical models. The net power output is improved by 11% when the gas turbine engine is supplied with cold air produced by the heat-pipe recovery and utilization system. It is further concluded from the results produced by the combined mathematical model that the thermal efficiency of the gas turbine engine rises to 6% at 75% part load. It is to be anticipated that this rising trend in increases of thermal efficiency of the gas turbine engine would continue for operations at other (lower) part load conditions. (author)

  1. Solar heating and cooling system for an office building at Reedy Creek Utilities


    The solar energy system installed in a two story office building at a utilities company, which provides utility service to Walt Disney World, is described. The solar energy system application is 100 percent heating, 80 percent cooling, and 100 percent hot water. The storage medium is water with a capacity of 10,000 gallons hot and 10,000 gallons chilled water. Performance to date has equaled or exceeded design criteria.

  2. Space manufacturing utilizing the directional electrostatic accretion process

    Mortensen, A.


    The Directional Electrostatic Accretion Process (DEAP) is described with respect to both the physical process and its application to manufacturing in space. This high precision portable manufacturing method will revolutionize current practices in manufacturing and repair of spacecraft and space structures. The cost effectiveness of this process will be invaluable to future space manufacturing projects.

  3. University Students' Views on the Utility of Psychiatric Advance Directives

    Scheyett, Anna M.; Rooks, Adrienne


    Objective: Rates of serious mental illnesses (SMIs) among university students are increasing, and universities are struggling with how to respond to students who show SMI symptoms. Psychiatric advance directives (PADs) allow individuals, when well, to document their wishes for treatment during a psychiatric crisis. This project explored the…

  4. Developing Multiple Diverse Potential Designs for Heat Transfer Utilizing Graph Based Evolutionary Algorithms

    David J. Muth Jr.


    This paper examines the use of graph based evolutionary algorithms (GBEAs) to find multiple acceptable solutions for heat transfer in engineering systems during the optimization process. GBEAs are a type of evolutionary algorithm (EA) in which a topology, or geography, is imposed on an evolving population of solutions. The rates at which solutions can spread within the population are controlled by the choice of topology. As in nature geography can be used to develop and sustain diversity within the solution population. Altering the choice of graph can create a more or less diverse population of potential solutions. The choice of graph can also affect the convergence rate for the EA and the number of mating events required for convergence. The engineering system examined in this paper is a biomass fueled cookstove used in developing nations for household cooking. In this cookstove wood is combusted in a small combustion chamber and the resulting hot gases are utilized to heat the stove’s cooking surface. The spatial temperature profile of the cooking surface is determined by a series of baffles that direct the flow of hot gases. The optimization goal is to find baffle configurations that provide an even temperature distribution on the cooking surface. Often in engineering, the goal of optimization is not to find the single optimum solution but rather to identify a number of good solutions that can be used as a starting point for detailed engineering design. Because of this a key aspect of evolutionary optimization is the diversity of the solutions found. The key conclusion in this paper is that GBEA’s can be used to create multiple good solutions needed to support engineering design.

  5. Persistent Directional Current at Equilibrium in Nonreciprocal Many-Body Near Field Electromagnetic Heat Transfer

    Zhu, Linxiao; Fan, Shanhui


    We consider the consequence of nonreciprocity in near-field heat transfer by studying systems consisting of magneto-optical nanoparticles. We demonstrate that, in thermal equilibrium, a nonreciprocal many-body system in heat transfer can support a persistent directional heat current, without violating the second law of thermodynamics. Such a persistent directional heat current cannot occur in reciprocal systems, and can only arise in many-body systems in heat transfer. The use of nonreciprocity therefore points to a new regime of near-field heat transfer for the control of heat flow in the nanoscale.

  6. Analysis of ice slurry production by direct contact heat transfer of air and water solution

    Xue-jun ZHANG; Ke-qing ZHENG; Ling-shi WANG; Wei WANG; Min JIANG; Sheng-ying ZHAO


    In this paper,a novel system using direct contact heat transfer between air and water solution was proposed to generate ice slurry.The heat transfer process and the system performance were studied;energy efficiency coefficients of 0.038,0.053,and 0.064 were obtained using different solutions.An empirical relationship between the volumetric heat transfer coefficient Uv and the main parameters was obtained by fitting the experimental data.The Uv calculated from the empirical formula agreed with the experimental Uv quite well with a relative error of less than 15%.Based on the empirical formula,a laboratory-scale direct contact ice slurry generator was then constructed,with practical application in mind.If the air flow rate is fixed at 200 m3/h,the ice production rate will be 0.091 kg/min.The experimental results also showed that the cold energy consumption of the air compressor accounted for more than half of the total amount.To improve the system energy efficiency coefficient,it is necessary to increase the air pipes insulation and the solution's thermal capacity,and also it is appropriate to utilize the free cold energy of liquefied natural gas(LNG).

  7. Performance evaluation and improvement directions for an Indian electric utility

    Yadav, Vinod Kumar, E-mail: [Electrical Engineering Department, Gautam Buddha University, Greater Noida 201310 (India); Padhy, N.P.; Gupta, H.O. [Electrical Engineering Department, Indian Institute of Technology, Roorkee 247667 (India)


    This study evaluates the performance of 29 Electricity Distribution Divisions (EDDs) of an Indian state - Uttarakhand - deploying Input oriented Data Envelopment Analysis (DEA). The results indicate that the performance of several EDDs is sub-optimal, suggesting the potential for cost reductions and possible reduction in employees number. In the DEA method more than one unit are identified as efficient. Therefore, this study suggests a method for ranking the efficient units by their importance as benchmarks for the inefficient units through benchmark share measure. The bigger the benchmark share, the more important an efficient division is in benchmarking for inefficient ones. Result reveals that plain area divisions are relatively efficient and have higher potential to influence the performance of inefficient EDDs. This study is envisaged to be instrumental to policy makers and managers to increase the operational efficiency of inefficient EDDs and thereby increase the competitiveness in the face of restructuring and liberalization of Indian electricity sector. - Highlights: > Plain area divisions are more effective in integrating resources than hilly divisions. > For prevalent inefficiency two models are developed to varying environmental conditions. > Benchmark share identifies the variable that is influential in increasing the efficiency. > Savings in terms of reduction in O and M cost and number of Employees. > Findings of research work redefine the view point of the utility planners.

  8. Initiative for local district heating. New chances for municipal utilities. Boundary conditions for the heat market; Initiative Nahwaerme. Neue Chancen fuer Stadtwerke. Rahmenbedingungen fuer den Waermemarkt

    Koenig, Michael [K.Group GmbH, Muenchen (Germany). Bereich Nachhaltige Energieversorgung und Stadtentwicklung


    In the regulated market, municipal utilities are forced to find new fields of activity. The heat market offers good chances. For example, local district heating grids can be established, independent power generation can be encouraged, and new services can be offered which may increase customer loyalty. The district heating initiative of the Baden-Wuerttemberg Minister of the Environment was launched early in 2009 with the intention to offer valuable assistance to the municipal utilities. (orig.)

  9. Encouragement of Enzyme Reaction Utilizing Heat Generation from Ferromagnetic Particles Subjected to an AC Magnetic Field.

    Suzuki, Masashi; Aki, Atsushi; Mizuki, Toru; Maekawa, Toru; Usami, Ron; Morimoto, Hisao


    We propose a method of activating an enzyme utilizing heat generation from ferromagnetic particles under an ac magnetic field. We immobilize α-amylase on the surface of ferromagnetic particles and analyze its activity. We find that when α-amylase/ferromagnetic particle hybrids, that is, ferromagnetic particles, on which α-amylase molecules are immobilized, are subjected to an ac magnetic field, the particles generate heat and as a result, α-amylase on the particles is heated up and activated. We next prepare a solution, in which α-amylase/ferromagnetic particle hybrids and free, nonimmobilized chitinase are dispersed, and analyze their activities. We find that when the solution is subjected to an ac magnetic field, the activity of α-amylase immobilized on the particles increases, whereas that of free chitinase hardly changes; in other words, only α-amylase immobilized on the particles is selectively activated due to heat generation from the particles.

  10. Encouragement of Enzyme Reaction Utilizing Heat Generation from Ferromagnetic Particles Subjected to an AC Magnetic Field.

    Masashi Suzuki

    Full Text Available We propose a method of activating an enzyme utilizing heat generation from ferromagnetic particles under an ac magnetic field. We immobilize α-amylase on the surface of ferromagnetic particles and analyze its activity. We find that when α-amylase/ferromagnetic particle hybrids, that is, ferromagnetic particles, on which α-amylase molecules are immobilized, are subjected to an ac magnetic field, the particles generate heat and as a result, α-amylase on the particles is heated up and activated. We next prepare a solution, in which α-amylase/ferromagnetic particle hybrids and free, nonimmobilized chitinase are dispersed, and analyze their activities. We find that when the solution is subjected to an ac magnetic field, the activity of α-amylase immobilized on the particles increases, whereas that of free chitinase hardly changes; in other words, only α-amylase immobilized on the particles is selectively activated due to heat generation from the particles.

  11. Characteristics of Vacuum Freeze Drying with Utilization of Internal Cooling and Condenser Waste Heat for Sublimation

    Muhammad Alhamid


    Full Text Available Vacuum freeze drying is an excellent drying method, but it is very energy-intensive because a relatively long drying time is required. This research investigates the utilization of condenser waste heat for sublimation as a way of accelerating the drying rate. In addition, it also investigates the effect of internal cooling combined with vacuum cooling in the pressure reduction process. Jelly fish tentacles were used as the specimen, with different configurations for condenser heat waste and internal cooling valve opening. The results show that heating with condenser heat waste can accelerate the drying rate up to 0.0035 kg/m2.s. In addition, pre-freezing by internal cooling prevents evaporation until the mass of the specimen is 0.47 g and promotes transition of the specimen into the solid phase.

  12. Temperature measurement methods during direct heat arterial tissue fusion.

    Cezo, James D; Kramer, Eric; Taylor, Kenneth D; Ferguson, Virginia; Rentschler, Mark E


    Fusion of biological tissues through direct and indirect heating is a growing area of medical research, yet there are still major gaps in understanding this procedure. Several companies have developed devices which fuse blood vessels, but little is known about the tissue's response to the stimuli. The need for accurate measurements of tissue behavior during tissue fusion is essential for the continued development and improvement of energy delivery devices. An experimental study was performed to measure the temperatures experienced during tissue fusion and the resulting burst pressure of the fused arteries. An array of thermocouples was placed in the lumen of a porcine splenic artery segment and sealed using a ConMed Altrus thermal fusion device. The temperatures within the tissue, in the device, and at the tissue-device interface were recorded. These measurements were then analyzed to calculate the temperature profile in the lumen of the artery. The temperature in the artery at the site of tissue fusion was measured to range from 142 to 163 °C using the ConMed Altrus. The corresponding burst pressure for arteries fused at this temperature was measured as 416 ± 79 mmHg. This study represents the first known experimental measurement of temperature at the site of vessel sealing found in the literature.

  13. Resource utilization and direct costs of pediatric HIV in Italy.

    Giacomet, V; Fabiano, V; Lo Muto, R; Caiazzo, M A; Curto, A; Rampon, O; Zuccotti, G V; Garattini, L


    This multicenter, prospective, observational study assessed the global economic impact of HIV care in a large cohort of HIV-infected children and adolescents in Italy. Three pediatric departments of reference participated on a voluntary basis. Centers were asked to enroll all their children during the period April 2010-March 2011. At enrollment, a pediatrician completed a questionnaire for each patient, including the type of service at access (outpatient consultation or day hospital), laboratory tests, instrumental examinations, specialists' consultations, antiretroviral therapy and opportunistic illness prophylaxis. Eligible patients had a confirmed diagnosis of HIV infection caused by direct vertical maternal-fetal transmission, their age ranging from 0 to 24 years. Since patients routinely have quarterly check-ups in all three centers, we adopted a three-month time horizon. Health-care services were priced using outpatient and inpatient tariffs. Drug costs were calculated by multiplying the daily dose by the public price for each active ingredient. A total of 142 patients were enrolled. More than half the patients were female and the mean age was 14 years, with no significant differences by center. There were substantial differences in health-care management among the three centers, particularly as regards the type of access. One center enrolled the majority of its patients in day-hospital and prescribed a large number of clinical tests, while children accessed another center almost exclusively through outpatient consultation. Drug therapy was the main cost component and was very similar in all three centers. The day-hospital was the second highest cost component, much higher than outpatient consultation (including examinations), leading to significant differences between total costs per center. These findings suggest that a recommendation to the Italian National Health Service would be to use more outpatient consultation for patients' access in order to

  14. Process of optimization of district heat production by utilizing waste energy from metallurgical processes

    Konovšek, Damjan; Fužir, Miran; Slatinek, Matic; Šepul, Tanja; Plesnik, Kristijan; Lečnik, Samo


    In a consortium with SIJ (Slovenian Steel Group), Metal Ravne, the local community of Ravne na Koro\\vskem and the public research Institut Jožef Stefan, with its registered office in Slovenia, Petrol Energetika, d.o.o. set up a technical and technological platform of an innovative energy case for a transition of steel industry into circular economy with a complete energy solution called »Utilization of Waste Heat from Metallurgical Processes for District Heating of Ravne na Koro\\vskem. This is the first such project designed for a useful utilization of waste heat in steel industry which uses modern technology and innovative system solutions for an integration of a smart, efficient and sustainable heating and cooling system and which shows a growth potential. This will allow the industry and cities to make energy savings, to improve the quality of air and to increase the benefits for the society we live in. On the basis of circular economy, we designed a target-oriented co-operation of economy, local community and public research institute to produce new business models where end consumers are put into the centre. This innovation opens the door for steel industry and local community to a joint aim that is a transition into efficient low-carbon energy systems which are based on involvement of natural local conditions, renewable energy sources, the use of waste heat and with respect for the principles of sustainable development.

  15. Utilization of waste heat from rotary kiln for burning clinker in the cement plant

    Sztekler Karol


    Full Text Available Cement subsector next to the glass industry is counted among one of the most energy-intensive industries, which absorbs approx. 12-15% of the total energy consumed by the industry. In the paper various methods of energy consumption reduction of in the cement industry are discussed. Cement production carries a very large emissions of greenhouse gases, where CO2 emissions on a global scale with the industry than approx. 5%. Great opportunity in CO2 emissions reduction in addition to the recovery of waste heat is also alternative fuels co-firing in cement kilns [1], [2]. In the cement sector interest in fitting-usable waste energy is growing in order to achieve high rates of savings and hence the financial benefits, as well as the environment ones [3]. In the process of cement production is lost irretrievably lot of energy and reduction of these losses on a global scale gives a visible saving of consumed fuel. The aim of this study is to investigate the possibility of waste heat use in Rudniki Cement Plant near to Czestochowa. After analyzing of all waste heat sources will be analyzed the heat emitted by radiation from the surface of the rotary kiln at the relevant facility. On the basis of thermal-flow calculations the most favorable radiative heat exchanger will be designed. The calculations based on available measurements provided by the cement plant, a thermal power of the heat exchanger, the heat exchange surface, the geometry of the heat exchanger, and other important parameters will be established. In addition the preliminary calculations of hydraulic losses and set directions for further work will be carried out. Direct benefits observed with the introduction of the broader heat recovery technology, is a significant increase in energy efficiency of the industrial process, which is reflected in the reduction of energy consumption and costs. Indirectly it leads to a reduction of pollution and energy consumption.

  16. Direct electronic measurement of Peltier cooling and heating in graphene

    Vera-Marun, I. J.; van den Berg, J. J.; Dejene, F. K.; van Wees, B. J.


    Thermoelectric effects allow the generation of electrical power from waste heat and the electrical control of cooling and heating. Remarkably, these effects are also highly sensitive to the asymmetry in the density of states around the Fermi energy and can therefore be exploited as probes of distort

  17. Effects of Fluid Directions on Heat Exchange in Thermoelectric Generators

    Suzuki, Ryosuke; Sasaki, Yuto; Fujisaka, Takeyuki


    Thermal fluids can transport heat to the large surface of a thermoelectric (TE) panel from hot and/or cold sources. The TE power thus obtainable was precisely evaluated using numerical calculations based on fluid dynamics and heat transfer. The commercial software FLUENT was coupled with a TE model...

  18. Research progresses and future directions on pool boiling heat transfer

    M. Kumar


    Full Text Available This paper reviews the previous work carried on pool boiling heat transfer during heating of various liquids and commodities categorized as refrigerants and dielectric fluids, pure liquids, nanofluids, hydrocarbons and additive mixtures, as well as natural and synthetic colloidal solutions. Nucleate pool boiling is an efficient and effective method of boiling because high heat fluxes are possible with moderate temperature differences. It is characterized by the growth of bubbles on a heated surface. It occurs during boiling of liquids for excess temperature ranging from 5 to 30 °C in various processes related to high vaporization of liquid for specific purposes like sugarcane juice heating for jaggery making, milk heating for khoa making, steam generation, cooling of electronic equipments, refrigeration and etcetera. In this review paper, pool boiling method during heating of liquids for specific purpose is depicted. It is inferred that enhancement in pool boiling heat transfer is a challenging and complex task. Also, recent research and use of various correlations for natural convection pool boiling is reviewed.

  19. Ionic Liquids for Utilization of Waste Heat from Distributed Power Generation Systems

    Joan F. Brennecke; Mihir Sen; Edward J. Maginn; Samuel Paolucci; Mark A. Stadtherr; Peter T. Disser; Mike Zdyb


    The objective of this research project was the development of ionic liquids to capture and utilize waste heat from distributed power generation systems. Ionic Liquids (ILs) are organic salts that are liquid at room temperature and they have the potential to make fundamental and far-reaching changes in the way we use energy. In particular, the focus of this project was fundamental research on the potential use of IL/CO2 mixtures in absorption-refrigeration systems. Such systems can provide cooling by utilizing waste heat from various sources, including distributed power generation. The basic objectives of the research were to design and synthesize ILs appropriate for the task, to measure and model thermophysical properties and phase behavior of ILs and IL/CO2 mixtures, and to model the performance of IL/CO2 absorption-refrigeration systems.

  20. Multiple utilization of energy in buildings. Utilization of waste heat at the Blood Transfusion Service; Energie im Gebaeude mehrfach nutzen. Abwaermenutzung beim Blutspendedienst Nord

    Gaigalat, Jens


    For the Blood Transfusion Service North the German Red Cross (Berlin, Federal Republic of Germany) utilizes the waste heat from production facilities and laboratories for heating offices. By doing this, the VRV technology for the realization of this solution was used.

  1. Session 4 - Utilizing Stove Heat for Co-Generation. Session Introduction


    in India “Wall Wart” Charger Rice Husks in the Philippines Alex Belonio Winner of 2008 Rolex Award Chinese Hybrid Gasifier Stove National Stove ...NOV 2009 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Utilizing Stove Heat for Co-Generation 5a. CONTRACT NUMBER 5b. GRANT...Generation Cook Stove Workshop Held in Bangkok, Thailand on November 16-20, 2009. U.S. Government or Federal Purpose Rights License, The original


    Schwantes, Jon M.


    The objective for this work was to demonstrate the utility of mechanistic computer models designed to simulate actinide behavior for use in efficiently and effectively directing advanced laboratory R&D activities associated with developing advanced separations methods.

  3. Nanoscale heat transfer in direct nanopatterning into gold films by a nanosecond laser pulse.

    Lin, Yuanhai; Zhai, Tianrui; Zhang, Xinping


    We investigate nanoscale heat transfer and heat-flux overlapping effects in nanopatterning through interactions between interferogram produced by 5-ns laser pulses at 355 nm and gold films. These mechanisms played different roles in direct writing of gold nanolines with different periods. Continuous gold nanolines were produced for large periods, where heat-flux overlapping is too small to effect the laser-metal interactions. Thus, the heat-transfer distance and direct laser-ablation determined the width of resultant gold nanolines. However, gold nanolines consisting of isolated gold nanoparticles were produced for small periods, where the overlapped heat-flux exceeds the threshold for removing or melting gold films.

  4. Sources and potential application of waste heat utilization at a gas processing facility

    Alshehhi, Alyas Ali

    Waste heat recovery (WHR) has the potential to significantly improve the efficiency of oil and gas plants, chemical and other processing facilities, and reduce their environmental impact. In this Thesis a comprehensive energy audit at Abu Dhabi Gas Industries Ltd. (GASCO) ASAB gas processing facilities is undertaken to identify sources of waste heat and evaluate their potential for on-site recovery. Two plants are considered, namely ASAB0 and ASAB1. Waste heat evaluation criteria include waste heat grade (i.e., temperature), rate, accessibility (i.e., proximity) to potential on-site waste heat recovery applications, and potential impact of recovery on installation performance and safety. The operating parameters of key waste heat source producing equipment are compiled, as well as characteristics of the waste heat streams. In addition, potential waste heat recovery applications and strategies are proposed, focusing on utilities, i.e., enhancement of process cooling/heating, electrical/mechanical power generation, and steam production. The sources of waste heat identified at ASAB facilities consist of gas turbine and gas generator exhaust gases, flared gases, excess propane cooling capacity, excess process steam, process gas air-cooler heat dissipation, furnace exhaust gases and steam turbine outlet steam. Of the above waste heat sources, exhaust gases from five gas turbines and one gas generator at ASAB0 plant, as well as from four gas turbines at ASAB1 plant, were found to meet the rate (i.e., > 1 MW), grade (i.e., > 180°C), accessibility (i.e., absorption refrigeration unit for gas turbine inlet air cooling, which would result in additional electric or mechanical power generation, and pre-cooling of process gas, which could reduce the need for or eliminate air coolers, as well as reduce propane chiller load, and ii) serve for heating of lean gas, which would reduce furnace load. At ASAB1, it is proposed that exhaust gases from all four gas turbines be used to

  5. Numerical Analysis of Lead-Bismuth-Water Direct Contact Boiling Heat Transfer

    Yamada, Yumi; Takahashi, Minoru

    Direct contact boiling heat transfer of sub-cooled water with lead-bismuth eutectic (Pb-Bi) was investigated for the evaluation of the performance of steam generation in direct contact of feed water with primary Pb-Bi coolant in upper plenum above the core in Pb-Bi-cooled direct contact boiling water fast reactor. An analytical two-fluid model was developed to estimate the heat transfer numerically. Numerical results were compared with experimental ones for verification of the model. The overall volumetric heat transfer coefficient was calculated from heat exchange rate in the chimney. It was confirmed that the calculated results agreed well with the experimental result.

  6. The utility of direct specimen detection by Sanger sequencing in hospitalized pediatric patients.

    Mongkolrattanothai, Kanokporn; Dien Bard, Jennifer


    Direct microbial DNA detection from clinical specimens by polymerase chain reaction and Sanger sequencing has been developed to address the innate limitations of traditional culture-based work-up. We report our institution's experience with direct specimen sequencing, its clinical utility, and barriers to effective clinical implementation.

  7. Direct measurement of heat transfer rates and coefficients in freezing processes by the use of heat flux sensors

    Amarante, A.; Lanoiselle, J.L.; Ramirez, A.


    Heat exchange is often complex to assess in freezing equipment. Either the extensive calculation procedures based on product time-temperature data, or the lack of accurate thermophysical properties, or even the non-uniform processing conditions in industrial equipment, results in increased difficulty in calculating accurate heat exchange parameters. The present study aims to solve this kind of problem by introducing the use of heat flux sensors (or fluxmeters) for an online measurement of heat exchange parameters during freezing processes. Since food products often have irregular, moist and greasy surfaces, bad attachment of the sensors can lead to low accuracy in heat flux measurement. First, a technique was improved in this particular and a numerical procedure based on matching the experimental and simulated temperature histories was used to calibrate the sensors attached to Tylose gels submitted to freezing and thawing cycles. Following this, the sensors were applied directly to a vegetable product undergoing freezing in a static freezer to measure the instantaneous product heat release rate and the local heat transfer coefficient. A fluxmeter-plastic transducer was also developed and used, coupled to an anemometer to map axially and transversally the local effective heat transfer coefficient and air speed profiles in a Super-Contact freezing tunnel. Results were compared with numerical simulations and showed good agreement. Irregular air speed distribution and low efficiency heat transfer zones were accurately detected, providing information for equipment optimization. (author)

  8. Drying of bio fuel utilizing waste heat; Torkning av biobraenslen med spillvaerme

    Johansson, Inge; Larsson, Sara; Wennberg, Olle [S.E.P. Scandinavian Energy Project AB, Goeteborg (Sweden)


    Many industries today have large sources of low grade heat (waste heat), however this energy is mainly lost with effluents to air and water. The aim of this study has been to investigate the technical and economical aspects of utilizing this low grade heat to dry biofuel. The project has been mainly focused towards the forest industry since they have both large amounts of biofuel and waste heat available. Drying of biofuel could generate added revenue (or reduced purchase costs) and through that also create larger incentives for further energy saving modifications to the main process. Due to the higher moisture content together with the risk of frozen bark in the winter time, additional fuels (such as oil) to combust bark in the existing boiler. This is mainly the case when mechanical dewatering is not available. Drying of bark results in an added energy value, which makes it possible to combust the bark without additional fuel. The primary energy demand, in the form of electricity and optional additional heating at load peaks, is low when waste heat is used for the drying process. In this way it is possible to increase the biofuel potential, since the primary energy input to the drying process is essentially lower then the increased energy value of the fuel. Drying also decreases the biological degradation of the fuel. Taking all the above into consideration, waste heat drying could result in a 25 % increase of the biofuel potential in the forest industry in Sweden, without additional cutting of wood. A survey has been done to state which commercial technologies are available for biofuel drying with waste heat. An inquiry was sent out to a number of suppliers and included a few different cases. Relations for approximating investment cost as well as electric power demand were created based on the answers from the inquiry. These relations have then been used in the economical evaluations made for a number of cases representing both sawmills and pulp and paper mills

  9. Novel Direct Steelmaking by Combining Microwave, Electric Arc, and Exothermal Heating Technologies

    Dr. Xiaodi Huang; Dr. J. Y. Hwang


    Steel is a basic material broadly used by perhaps every industry and individual. It is critical to our nation's economy and national security. Unfortunately, the American steel industry is losing competitiveness in the world steel production field. There is an urgent need to develop the next generation of steelmaking technology for the American steel industry. Direct steelmaking through the combination of microwave, electric arc, and exothermal heating is a revolutionary change from current steelmaking technology. This technology can produce molten steel directly from a shippable agglomerate, consisting of iron oxide fines, powdered coal, and ground limestone. This technology is projected to eliminate many current intermediate steelmaking steps including coking, pellet sintering, blast furnace (BF) ironmaking, and basic oxygen furnace (BOF) steelmaking. This technology has the potential to (a) save up to 45% of the energy consumed by conventional steelmaking; (b) dramatically reduce the emission of CO{sub 2}, SO{sub 2}, NO{sub x}, VOCs, fine particulates, and air toxics; (c) substantially reduce waste and emission control costs; (d) greatly lower capital cost; and (e) considerably reduce steel production costs. This technology is based on the unique capability of microwaves to rapidly heat steelmaking raw materials to elevated temperature, then rapidly reduce iron oxides to metal by volumetric heating. Microwave heating, augmented with electric arc and exothermal reactions, is capable of producing molten steel. This technology has the components necessary to establish the ''future'' domestic steel industry as a technology leader with a strong economically competitive position in world markets. The project goals were to assess the utilization of a new steelmaking technology for its potential to achieve better overall energy efficiency, minimize pollutants and wastes, lower capital and operating costs, and increase the competitiveness of the

  10. A new power generation method utilizing a low grade heat source

    Wei-feng WU; Kin-ping LONG; Xiao-ling YU; Quan-ke FENG


    Energy crisis make the effective use of low grade energy more and more urgent.It is still a worldwide difficult conundrum.To efficiently recover low grade heat,this paper deals with a theoretical analysis of a new power generation method driven by a low grade heat source.When the temperature of the low grade heat source exceeds the saturated temperature,it can heat the liquid into steam.If the steam is sealed and cooled in a container,it will lead to a negative pressure condition.The proposed power generation method utilizes the negative pressure condition in the sealed container,called as a condensator.When the condensator is connected to a liquid pool,the liquid will be pumped into it by the negative pressure condition.After the condensator is filled by liquid,the liquid flows back into the pool and drives the turbine to generate electricity.According to our analysis,for water,the head pressure of water pumped into the condensator could reach 9.5 m when the temperature of water in the pool is 25 ℃,and the steam temperature is 105 ℃.Theoretical thermal efficiency of this power generation system could reach 3.2% to 5.8% varying with the altitude of the condensator to the water level,ignoring steam leakage loss.

  11. Thermal distillation system utilizing biomass energy burned in stove by means of heat pipe

    Hiroshi Tanaka


    Full Text Available A thermal distillation system utilizing a part of the thermal energy of biomass burned in a stove during cooking is proposed. The thermal energy is transported from the stove to the distiller by means of a heat pipe. The distiller is a vertical multiple-effect diffusion distiller, in which a number of parallel partitions in contact with saline-soaked wicks are set vertically with narrow gaps of air. A pilot experimental apparatus was constructed and tested with a single-effect and multiple-effect distillers to investigate primarily whether a heat pipe can transport thermal energy adequately from the stove to the distiller. It was found that the temperatures of the heated plate and the first partition of the distiller reached to about 100 °C and 90 °C, respectively, at steady state, showing that the heat pipe works sufficiently. The distilled water obtained was about 0.75 and 1.35 kg during the first 2 h of burning from a single-effect and multiple-effect distillers, respectively.

  12. Heat transfer augmentation of magnetohydrodynamics natural convection in L-shaped cavities utilizing nanofluids

    Sourtiji Ehsan


    Full Text Available A numerical study of natural convection heat transfer through an alumina-water nanofluid inside L-shaped cavities in the presence of an external magnetic field is performed. The study has been carried out for a wide range of important parame­ters such as Rayleigh number, Hartmann number, aspect ratio of the cavity and solid volume fraction of the nanofluid. The influence of the nanoparticle, buoyancy force and the magnetic field on the flow and temperature fields have been plotted and discussed. The results show that after a critical Rayleigh number depending on the aspect ratio, the heat transfer in the cavity rises abruptly due to some significant changes in flow field. It is also found that the heat transfer enhances in the presence of the nanoparticles and increases with solid volume fraction of the nanofluid. In addition, the performance of the nanofluid utilization is more effective at high Ray­leigh numbers. The influence of the magnetic field has been also studied and de­duced that it has a remarkable effect on the heat transfer and flow field in the cavity that as the Hartmann number increases the overall Nusselt number is significantly decreased specially at high Rayleigh numbers.

  13. Organic Rankine Cycle Analysis: Finding the Best Way to Utilize Waste Heat

    Nadim Chakroun


    Full Text Available An Organic Rankine Cycle (ORC is a type of power cyclethat uses organic substances such as hydrocarbons orrefrigerants as the working fluid. ORC technology is usedto generate electricity in waste heat recovery applications,because the available heat is not at a high enoughtemperature to operate with other types of cycles. Theoptimum amount of working fluid required for the cycle(i.e., optimum charge level was investigated. Three chargelevels (13, 15, and 18 lbm were tested, and their effect onefficiency and performance of the system was analyzed.The heat source for the fluid was waste steam from thePurdue Power Plant, which had an average temperatureof 120oC. Regular city tap water at a temperature of 15oCwas used as the heat sink. For each charge level, multipletests were performed by measuring the temperaturesand pressures at all state points in the cycle, in order tounderstand any overarching patterns within the data.An important parameter that was analyzed is the 2nd lawefficiency. This efficiency is a measure of the effectivenessof the energy utilization compared to that of an idealcase. The peak efficiency increased from 24% to 27% asthe charge in the system decreased. Therefore, movingforward, this research suggests that a lower charge levelin the system will increase efficiency. However, testingbelow 13 lbm might cause mechanical complications inthe equipment as there may not be enough fluid to flowaround; thus, a compromise had to be made.

  14. Organic Rankine-cycle turbine power plant utilizing low temperature heat sources

    Maizza, V.


    Utilizing and converting of existing low temperature and waste heat sources by the use of a high efficiency bottoming cycle is attractive and should be possible for many locations. This paper presents a theoretical study on possible combination of an organic Rankine-cycle turbine power plate with the heat pump supplied by waste energy sources. Energy requirements and system performances are analyzed using realistic design operating condition for a middle town. Some conversion systems employing working fluids other than water are being studied for the purpose of proposed application. Thermodynamic efficiencies, with respect to available resource, have been calculated by varying some system operating parameters at various reference temperature. With reference to proposed application equations and graphs are presented which interrelate the turbine operational parameters for some possible working fluids with computation results.

  15. Effect of adaptive abilities on utilities, direct or mediated by mental health?

    Vliet Vlieland Thea PM


    Full Text Available Abstract Background In cost-utility analyses gain in health can be measured using health state utilities. Health state utilities can be elicited from members of the public or from patients. Utilities given by patients tend to be higher than utilities given by members of the public. This difference is often suggested to be explained by adaptation, but this has not yet been investigated in patients. Here, we investigate if, besides health related quality of life (HRQL, persons' ability to adapt can explain health state utilities. Both the direct effect of persons' adaptive abilities on health state utilities and the indirect effect, where HRQL mediates the effect of ability to adapt, are examined. Methods In total 125 patients with Rheumatoid Arthritis were interviewed. Participants gave valuations of their own health on a visual analogue scale (VAS and time trade-off (TTO. To estimate persons' ability to adapt, patients filled in questionnaires measuring Self-esteem, Mastery, and Optimism. Finally they completed the SF-36 measuring HRQL. Regression analyses were used to investigate the direct and mediated effect of ability to adapt on health state utilities. Results Persons' ability to adapt did not add considerably to the explanation of health state utilities above HRQL. In the TTO no additional variance was explained by adaptive abilities (Δ R2 = .00, β = .02, in the VAS a minor proportion of the variance was explained by adaptive abilities (Δ R2 = .05, β = .33. The effect of adaptation on health state utilities seems to be mediated by the mental health domain of quality of life. Conclusions Patients with stronger adaptive abilities, based on their optimism, mastery and self-esteem, may more easily enhance their mental health after being diagnosed with a chronic illness, which leads to higher health state utilities.

  16. Solar heating and cooling system for an office building at Reedy Creek Utilities


    This final report describes in detail the solar energy system installed in a new two-story office building at the Reedy Creek Utilities Company, which provides utility service to Walt Disney World at Lake Buena Vista, Florida. The solar components were partly funded by the Department of Energy under Contract EX-76-C-01-2401, and the technical management was by NASA/George C. Marshall Space Flight Center. The solar energy system application is 100 percent heating, 80 percent cooling, and 100 percent hot water. The collector is a modular cylindrical concentrator type with an area of 3.840 square feet. The storage medium is water with a capacity of 10,000 gallons hot and 10,000 gallons chilled. Design, construction, operation, cost, maintenance, and performance are described in depth. Detailed drawings are included.

  17. Modeling and Experimental Validation of a Transient Direct Expansion Heat Pump

    Clément Rousseau


    Full Text Available Geothermal heat pump technology is currently one of the most interesting technologies used to heat buildings. There are two designs used in the industry: geothermal heat pump using a secondary ground loop and Direct Expansion (DX ground source heat pump. The latter is less used, possibly because less research has been carried out for the design of this kind of heat pump. In this paper, a transient model using the Comsol Multiphysic of a DX ground heat pump is presented in heating mode with R22, and a comparison with experimental results is presented with a 24-hour test. It is shown that the model was adequately validated by our experiment with only a maximum difference of 15%. Following this validation, a parametric analysis was realised on the geometry of the borehole. This study concluded that to have the best heat extraction of the ground, the pipes shank spacing need to be important without increasing the borehole diameter. Keywords: Direct Expansion geothermal heat pump, Modeling, R22 Article History: Received January 16th 2017; Received in revised form May 28th 2017; Accepted June 6th 2017; Available online How to Cite This Article: Rousseau, C., Fannou, J.L.C., Lamarche, L. and Kajl, S. (2017 Modeling and Experimental Validation of a Transient Direct Expansion Heat Pump. International Journal of Renewable Energy Develeopment, 6(2, 145-155.

  18. Direct contact liquid-liquid heat exchanger for solar-heated and cooled buildings

    Karaki, S.; Brothers, P.


    The procedure used was to obtain experimental performance data from a solar system using a DCLLHE for both heating and cooling functions, develop a simulation model for the system, validate the model using the data, apply the model in five different climatic regions of the country for a complete year, and estimate the life-cycle cost of the system for each application. The results are compared to a conventional solar system, using a standard shell-and-tube heat exchanger.

  19. Utilization of the horizontal ground heat exchanger in the heating and cooling system of a residential building

    Hanuszkiewicz-Drapała Małgorzata


    Full Text Available This paper presents the results of thermodynamic analyses of a system using a horizontal ground heat exchanger to cool a residential building in summer and heat it in the autumn-winter period. The main heating device is a vapour compression heat pump with the ground as the lower heat source. The aim of the analyses is to examine the impact of heat supply to the ground in the summer period, when the building is cooled, on the operation of the heating system equipped with a heat pump in the next heating season, including electricity consumption. The processes occurring in cooling and heating systems have an unsteady nature. The main results of the calculations are among others the time-dependent values of heat fluxes extracted from or transferred to the ground heat exchanger, the fluxes of heat generated by the heat pump and supplied to the heated building by an additional heat source, the parameters in characteristic points of the systems, the temperature distributions in the ground and the driving electricity consumption in the period under analysis. The paper presents results of analysis of cumulative primary energy consumption of the analyzed systems and cumulative emissions of harmful substances.

  20. Utilization of the horizontal ground heat exchanger in the heating and cooling system of a residential building

    Hanuszkiewicz-Drapała, Małgorzata; Bury, Tomasz


    This paper presents the results of thermodynamic analyses of a system using a horizontal ground heat exchanger to cool a residential building in summer and heat it in the autumn-winter period. The main heating device is a vapour compression heat pump with the ground as the lower heat source. The aim of the analyses is to examine the impact of heat supply to the ground in the summer period, when the building is cooled, on the operation of the heating system equipped with a heat pump in the next heating season, including electricity consumption. The processes occurring in cooling and heating systems have an unsteady nature. The main results of the calculations are among others the time-dependent values of heat fluxes extracted from or transferred to the ground heat exchanger, the fluxes of heat generated by the heat pump and supplied to the heated building by an additional heat source, the parameters in characteristic points of the systems, the temperature distributions in the ground and the driving electricity consumption in the period under analysis. The paper presents results of analysis of cumulative primary energy consumption of the analyzed systems and cumulative emissions of harmful substances.

  1. Geothermal technology transfer for direct heat applications: Final report, 1983--1988

    Lienau, P.J.; Culver, G.


    This report describes a geothermal technology transfer program, performed by Oregon Institute of Technology's Geo-Heat Center, used to aid in the development of geothermal energy for direct heat applications. It provides a summary of 88 technical assistance projects performed in 10 states for space heating, district heating, green-houses, aquaculture, industrial processing, small scale binary electric power generation and heat pump applications. It describes an inventory compiled for over 100 direct heat projects that contains information on project site, resource and engineering data. An overview of information services is provided to users of the program which includes; advisory, referrals, literature distribution, geothermal technology library, quarterly Bulletin, training programs, presentations and tours, and reporting of activities for the USDOE Geothermal Progress Monitor.

  2. Economic assessment of geothermal direct heat technology: A review of five DOE demonstration projects

    Hederman, William F. Jr.; Cohen, Laura A.


    In this report the cost of using low temperature geothermal energy resources for direct heating applications is compared to the costs associated with conventional heating fuels. The projects compared all involved replacing conventional fuels (e.g., natural gas and fuel oils) with geothermal energy in existing heating systems. The cost of using geothermal energy in existing systems was also compared with the cost of new coal-fired equipment.

  3. The Microwave Direct Heating of Zeolite FAU in an Open System


    Zeolite FAU was heated directly by microwave irradiation at 2450 MHz in an open system without special loading materials. It was discovered that zeolite X was heated to 1473 K about 90 seconds at power output of 400 W. HY type zeolite was also heated to 1373 K although it needed relative long time (about 11 minutes). Influences of exchangeable cations and adsorbed substances on zeolite1s ability to absorb microwaves were also discussed.

  4. The Microwave Direct Heating of Zeolite FAU in an Open System

    JinXiangDONG; FengWU; 等


    Zeolite FAU was heated directly by microwave irradiation at 2450 MHz is in open system without special loading materials. It was discovered that zeolite X was heated to 1473K about 90 seconds at power output of 400W. HY type zeolite was also heated to 1373K although in needed relative long time (about 11 minutes). Influences of exchangeable cations and adsorbed substances on zeolite′s ability to absorb microwaves were also discussed.

  5. Mechanisms of direct detonation initiation via thermal explosion of radiatively heated gas-particles layer

    Efremov, V. P.; Ivanov, M. F.; Kiverin, A. D.; Yakovenko, I. S.

    Conceptual approach of detonation wave direct initiation by external radiative heating of microparticles locally suspended in flammable gaseous mixture is proposed. Combustion waves and detonation initiation mechanisms in the congestion regions of microparticles heated by radiation are studied numerically. Necessary criteria on geometrical scales of gas-particles layer and spatial uniformity of particles distribution for successful detonation initiation are formulated.

  6. Skin and muscle components of forearm blood flow in directly heated resting man.

    Detry, J.-M. R.; Brengelmann, G. L.; Rowell, L. B.; Wyss, C.


    Changes in forearm muscle blood flow (FMBF) during direct whole-body heating were measured in 17 normal subjects using three different methods. We conclude that FMBF is not increased by direct whole-body heating. Since renal and splanchnic blood flow fall 30% under these conditions, maximal total skin blood flow in 12 previously studied subjects can be estimated from the rise in cardiac output to be 7.6 L/min (3.0-11.1 L/min).

  7. Feasibility of direct utilization of selected geothermal water for aquaculture of macrobrachium rosenbergii. Technical report

    Spinosa, C.


    The feasibility was tested of direct utilization of geothermal water for the aquaculture of Malaysian freshwater prawns (Macrobrachium rosenbergii). A problem with using geothermal water for aquaculture is the chemical composition of the water with high flouride levels being a particular problem. Results show that (1) some geothermal water in Idaho can be used directly for the aquaculture of Macrobrachium rosenbergii, (2) high flouride levels cannot be directly correlated with high mortality rates and (3) low flouride levels do not correlate with high growth rates.

  8. Analysis of a liquid/gas direct contact heat exchanger concept

    Warrington, R. O.; Mussulman, R. L.


    The performance of spray heat exchangers employing uniform drop generators is analyzed using a computer simulation of the air/water counterflow direct contact heat exchanger for the cases of heat transfer from water to air, and from air to water. The effect of air temperature and humidity on water cooling is demonstrated. For the case of air cooling, the dry bulb temperature reduction achieved in the chiller is insensitive to humidity. The effects of heat exchanger size and droplet size are also considered.

  9. A comparison of microwave versus direct solar heating for lunar brick production

    Yankee, S. J.; Strenski, D. G.; Pletka, B. J.; Patil, D. S.; Mutsuddy, B. C.


    Two processing techniques considered suitable for producing bricks from lunar regolith are examined: direct solar heating and microwave heating. An analysis was performed to compare the two processes in terms of the amount of power and time required to fabricate bricks of various sizes. Microwave heating was shown to be significantly faster than solar heating for rapid production of realistic-size bricks. However, the relative simplicity of the solar collector(s) used for the solar furnace compared to the equipment necessary for microwave generation may present an economic tradeoff.

  10. Indirect and Mixed Direct-Indirect Heat Integration of Batch Processes Based on Pinch Analysis

    Daniel Favrat


    Full Text Available

    This paper introduces a methodology for the heat integration of industrial batch processes. Based on Pinch Analysis principles, this methodology resorts to intermediate heat storage to prevent adverse effects on the operating flexibility, which are often associated with direct heat exchange only. A systematic procedure, backed with a graphical representation, allows the determination of the minimum number of heat storage units assuming vertical heat transfer and their range of feasible operation as a function of the amount of heat recovery. Understanding the cause and the bottleneck effect of the socalled storage pinch, heuristic rules are proposed to screen major options corresponding to minimum cost solutions. For a given number of heat storage units, these rules could be automated to a large extent, making the procedure suitable for targeting purposes. The operating temperature of the heat storage units can be optimized with ease, while other continuous degrees of freedom are more difficult to address using the proposed methodology. Preliminary guidelines are proposed to extend the methodology to mixed direct-indirect heat integration.

    •  This paper was presented at the ECOS’00 Conference in Enschede, July 5-7, 2000 and revised

  11. Experimental analysis of direct-expansion ground-coupled heat pump systems

    Mei, V. C.; Baxter, V. D.


    Direct-expansion ground-coil-coupled (DXGC) heat pump systems have certain energy efficiency advantages over conventional ground-coupled heat pump (GCHP) systems. Principal among these advantages are that the secondary heat transfer fluid heat exchanger and circulating pump are eliminated. While the DXGC concept can produce higher efficiencies, it also produces more system design and environmental problems (e.g., compressor starting, oil return, possible ground pollution, and more refrigerant charging). Furthermore, general design guidelines for DXGC systems are not well documented. A two-pronged approach was adopted for this study: (1) a literature survey, and (2) a laboratory study of a DXGC heat pump system with R-22 as the refrigerant, for both heating and cooling mode tests done in parallel and series tube connections. The results of each task are described in this paper. A set of general design guidelines was derived from the test results and is also presented.

  12. Utilization of the PCM latent heat for energy savings in buildings

    Fořt, Jan; Trník, Anton; Pavlík, Zbyšek


    Increase of the energy consumption for buildings operation creates a great challenge for sustainable development issues. Thermal energy storage systems present promising way to achieve this goal. The latent heat storage systems with high density of thermal storage via utilization of phase change materials (PCMs) enable to improve thermal comfort of buildings and reduce daily temperature fluctuations of interior climate. The presented study is focused on the evaluation of the effect of PCM admixture on thermal performance of a cement-lime plaster. On the basis of the experimentally accessed properties of newly developed plasters, computational modeling is carried out in order to rate the acquired thermal improvement. The calculated results show that incorporation of 24 mass% of paraffinic wax based PCM decreased the energy demand of approx. 14.6%.

  13. Personal utility is inherent to direct-to-consumer genomic testing.

    Chung, Matthew Wai Heng; Ng, Joseph Chi Fung


    People for and against direct-to-consumer (DTC) genomic tests are arguing around two issues: first, on whether an autonomy-based account can justify the tests; second, on whether the tests bring any personal utility. Bunnik et al, in an article published in this journal, were doubtful on the latter, especially in clinically irrelevant and uninterpretable sequences, and how far this claim could go in the justification. Here we argue that personal utility is inherent to DTC genomic tests and their results. We discuss Bunnik et al's account of personal utility and identify problems in its motivation and application. We then explore concepts like utility and entertainment which suggest that DTC genomic tests bring personal utility to their consumers, both in the motivation and the content of the tests. This points to an alternative account of personal utility which entails that entertainment value alone is adequate to justify DTC genomic tests, given appropriate strategies to communicate tests results with the consumers. It supports the autonomy-based justification of the test by showing that DTC genomic test itself stands as a valuable option and facilitates meaningful choice of the people. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to

  14. Augmentation of Cooling Output by Silica Gel-Water Adsorption Cycle Utilizing the Waste Heat of GHP

    Homma, Hiroki; Araki, Nobuyuki

    The GHP (Gas engine Heat Pump) system is expected to have high energy-efficiency in utilizing the waste heat exhausted from a gas engine. In summer season, a silica gel-water adsorption cooling unit driven by the exhaust heat is considered as a cooling system for saving energy. In this work, an attempt was made to improve the COP of a silica gel-water adsorption cooling system by enhancing heat and mass transfer in the silica gel adsorption layer. A unit cell was introduced as a simplified model of adsorber for analyzing the phenomena of heat and mass transfer in the adsorbent. This cell was composed of a single tube with a silica gel layer bonded on its external surface. Optimization of heat and mass transfer characteristics for the unit cell was carried out by experimental and analytical approach.

  15. Direct medical resource utilization associated with osteoporosis-related nonvertebral fractures in postmenopausal women.

    Jean, Sonia; Bessette, Louis; Belzile, Etienne L; Davison, K Shawn; Candas, Bernard; Morin, Suzanne; Dodin, Sylvie; Brown, Jacques P


    The purposes of this study were to assess direct medical resource utilization related to the treatment of nonvertebral osteoporotic fractures within 1 year postfracture and to evaluate whether age impacts resource utilization. A previously-validated algorithm for physician claims databases identified 15,327 women aged 50 years or older with incident fracture at nonvertebral osteoporotic sites between January 1, 2004 and December 31, 2005. Administrative databases of the health services available to all residents in Quebec served to study fracture-related health resource utilization in the year after fracture. Data were linked by a unique personal identifier, creating a longitudinal cohort of all fracture cases for health resource utilization. The proportions of fractures treated by open reduction, closed reduction, immobilization or follow-up by an orthopedic surgeon (OS) were evaluated. The mean number of claims for consultation with an OS or other clinicians in inpatient and outpatient visits, the hospitalization rate and length of stay (LOS) were assessed. Hip/femur fractures represented the highest rate of resource utilization because the majority of them required surgery (91.1%) and hospitalization (94.5%) with a mean (median) LOS of 39.2 (31) days. However, other nonvertebral fracture types needed significant clinical care related to surgery (27.9%), follow-up consultation with an OS (77.6%), and hospitalization (27.3% of total LOS). Even pelvic fractures, which often do not require surgical treatment, commanded high resource utilization due to the high hospitalization rate (67.4%) with mean (median) LOS of 34.2 (26) days. Moreover, age was an important determinant of health resource utilization, being associated with an increased number of visits to other physicians, hospitalization, and length of hospitalization (LOS), admissions to long term care (LTC), and death. Osteoporosis-related fractures accounted for substantial healthcare resource utilization

  16. Heat Pump Water Heater Technology: Experiences of Residential Consumers and Utilities

    Ashdown, BG


    benefits. Because it produces hot water by extracting heat from the air it tends to dehumidify and cool the room in which it is placed. Moreover, it tends to spread the water heating load across utility non-peak periods. Thus, electric utilities with peak load issues could justify internal programs to promote this technology to residential and commercial customers. For practical purposes, consumers are indifferent to the manner in which water is heated but are very interested in product attributes such as initial first cost, operating cost, performance, serviceability, product size, and installation costs. Thus, the principal drivers for penetrating markets are demonstrating reliability, leveraging the dehumidification attributes of the HPWH, and creating programs that embrace life-cycle cost principles. To supplement this, a product warranty with scrupulous quality control should be implemented; first-price reduction through engineering, perhaps by reducing level of energy efficiency, should be pursued; and niche markets should be courted. The first step toward market penetration is to address the HPWH's performance reliability. Next, the manufacturers could engage select utilities to aggressively market the HPWH. A good approach would be to target distinct segments of the market with the potential for the highest benefits from the technology. Communications media that address performance issues should be developed. When marketing to new home builders, the HPWH could be introduced as part of an energy-efficient package offered as a standard feature by builders of new homes within a community. Conducting focus groups across the United States to gather input on HPWH consumer values will feed useful data back to the manufacturers. ''Renaming'' and ''repackaging'' the HPWH to improve consumer perception, appliance aesthetics, and name recognition should be considered. Once an increased sales volume is achieved, the manufacturers

  17. Numerical simulation of boundary heat flow effects on directional solidification microstructure of a binary alloy

    Xue Xiang


    Full Text Available The boundary heat flow has important significance for the microstructures of directional solidified binary alloy. Interface evolution of the directional solidified microstructure with different boundary heat flow was discussed. In this study, only one interface was allowed to have heat flow, and Neumann boundary conditions were imposed at the other three interfaces. From the calculated results, it was found that different boundary heat flows will result in different microstructures. When the boundary heat flow equals to 20 W·cm-2, the growth of longitudinal side branches is accelerated and the growth of transverse side branches is restrained, and meanwhile, there is dendritic remelting in the calculation domain. When the boundary heat flow equals to 40 W·cm-2, the growths of the transverse and longitudinal side branches compete with each other, and when the boundary heat flow equals to 100-200 W·cm-2, the growth of transverse side branches dominates absolutely. The temperature field of dendritic growth was analyzed and the relation between boundary heat flow and temperature field was also investigated.

  18. Numerical simulation of boundary heat flow effects on directional solidification microstructure of a binary alloy

    Xue Xiang; Tang Jinjun


    The boundary heat flow has important significance for the microstructures of directional solidified binary alloy. Interface evolution of the directional solidified microstructure with different boundary heat flow was discussed. In this study, only one interface was allowed to have heat flow, and Neumann boundary conditions were imposed at the other three interfaces. From the calculated results, it was found that different boundary heat flows will result in different microstructures. When the boundary heat flow equals to 20 W-cm-2, the growth of longitudinal side branches is accelerated and the growth of transverse side branches is restrained, and meanwhile, there is dendritic remelting in the calculation domain. When the boundary heat flow equals to 40 W-cm-2, the growths of the transverse and longitudinal side branches compete with each other, and when the boundary heat flow equals to 100-200 W-cm-2, the growth of transverse side branches dominates absolutely. The temperature field of dendritic growth was analyzed and the relation between boundary heat flow and temperature field was also investigated.

  19. Comparison of Direct Solar Energy to Resistance Heating for Carbothermal Reduction of Regolith

    Muscatello, Anthony C.; Gustafson, Robert J.


    A comparison of two methods of delivering thermal energy to regolith for the carbo thermal reduction process has been performed. The comparison concludes that electrical resistance heating is superior to direct solar energy via solar concentrators for the following reasons: (1) the resistance heating method can process approximately 12 times as much regolith using the same amount of thermal energy as the direct solar energy method because of superior thermal insulation; (2) the resistance heating method is more adaptable to nearer-term robotic exploration precursor missions because it does not require a solar concentrator system; (3) crucible-based methods are more easily adapted to separation of iron metal and glass by-products than direct solar energy because the melt can be poured directly after processing instead of being remelted; and (4) even with projected improvements in the mass of solar concentrators, projected photovoltaic system masses are expected to be even lower.

  20. A study on modeling and performance assessment of a heat pump system for utilizing low temperature geothermal resources in buildings

    Hepbasli, Arif [Department of Mechanical Engineering, Faculty of Engineering, Ege University, 35100 Bornova, Izmir (Turkey); Tolga Balta, M. [Department of Mechanical Engineering, Aksaray Engineering Faculty, Nigde University, 68100 Aksaray (Turkey)


    Low and moderate geothermal resources are found in most areas of the world. A very efficient way to heat and air-condition homes and buildings is the utilization of ground source heat pumps (GSHPs), also known as geothermal heat pump (GHPs), to obtain heat energy from low temperature geothermal resources. The present study deals with the modeling and performance evaluation of a heat pump system utilizing a low temperature geothermal resource, which is approximated to a geothermal reservoir. The system was designed, constructed and tested in Nigde University, Nigde, Turkey and has been successfully operated since 2005. Energy and exergy analysis methods were used to assess the system performance based on the experimental data. Exergy destructions (or irreversibilities) as well as energy and exergy efficiency relations were presented for each component of the heat pump unit and the whole system, while some thermodynamic parameters, such as fuel depletion ratio, relative irreversibility, productivity lack, exergetic factor and improvement potential, were investigated for the system. Energy and exergy efficiency values on a product/fuel basis were found to range from 73.9% to 73.3% and 63.3% to 51.7% at dead (reference) state temperatures varying from 0 to 25 C for the heat pump unit and entire system, respectively. It is expected that the model presented here would be beneficial to the researchers, government administration, and engineers working in the area of heat pump systems for residential applications. (author)

  1. Utilization of process energy from supermarket refrigeration systems. Coupling of cooling and heating; Prozessenergienutzung von Supermarktkaelteanlagen. Kaelte-Waerme-Kopplung

    Wirsching, Alexander [TEKO Gesellschaft fuer Kaeltetechnik mbH, Altenstadt (Germany). Technologie und Kommunikation


    The efficiency is defined as the relation between utility and expenditure. Thus, it is obvious for the specialist of refrigeration to tackle with the expenditure (energy consumption) since the utilization conventionally is defined as the produced/need cooling performance of a refrigeration plant. If refrigeration plants are regarded according to their function (withdrawal of heat from a refrigeration chamber and delivery to the environment), the heating system is the producer of the requirement for cooling in 'the winter' (heating season). Thus, the refrigeration plant perhaps already has a marvellous efficiency, and the separate heating system too - however in interaction. The broad view moves into the focus. The possible approaches and effects are described in the contribution under consideration using the example of a Discount supermarket with a sales area of 800 square meters and a requirement of cooling of more than 30 kW.

  2. Heat waves and morbidity: current knowledge and further direction-a comprehensive literature review.

    Li, Mengmeng; Gu, Shaohua; Bi, Peng; Yang, Jun; Liu, Qiyong


    In the past few decades, several devastating heat wave events have significantly challenged public health. As these events are projected to increase in both severity and frequency in the future, it is important to assess the relationship between heat waves and the health indicators that can be used in the early warning systems to guide the public health response. Yet there is a knowledge gap in the impact of heat waves on morbidity. In this study, a comprehensive review was conducted to assess the relationship between heat waves and different morbidity indicators, and to identify the vulnerable populations. The PubMed and ScienceDirect database were used to retrieve published literature in English from 1985 to 2014 on the relationship between heat waves and morbidity, and the following MeSH terms and keywords were used: heat wave, heat wave, morbidity, hospital admission, hospitalization, emergency call, emergency medical services, and outpatient visit. Thirty-three studies were included in the final analysis. Most studies found a short-term negative health impact of heat waves on morbidity. The elderly, children, and males were more vulnerable during heat waves, and the medical care demand increased for those with existing chronic diseases. Some social factors, such as lower socioeconomic status, can contribute to heat-susceptibility. In terms of study methods and heat wave definitions, there remain inconsistencies and uncertainties. Relevant policies and guidelines need to be developed to protect vulnerable populations. Morbidity indicators should be adopted in heat wave early warning systems in order to guide the effective implementation of public health actions.

  3. 使用第二种热泵对排热进行利用%The waste heat utilization by an absorption heat transformer

    人江智芳; 都津馨(译)


    低温排热,例如低于100℃的排水,因为温度太低,通常难以再利用。一种热吸收转换装置(热泵)能利用这些低温排热产生180℃的蒸汽。单段热吸收转换器在特性理论系数C O P为0.5时,能产生120℃的蒸汽。当特性理论系数COP分别为0.33和0.25时,相对应的两段和三段热吸收转换器能产生180℃的蒸汽。%The low temperature heat sources such as hot water less than 100℃ are usually dififcult to be utilized because the temperature is too low. An absorption heat transformer (heat pump) was developed to generate 180℃ steam by utilizing these low temperature heat sources. A single lift absorption heat transformer generate 120℃ steam in theoretical COP 0.5. A double lift and triple lift absorption heat transformer generate 180℃ steam in theoretical COP 0.33 and 0.25, respectively.

  4. Development of a Direct Contact Heat Exchanger, Phase 1 Study Report

    Manvi, R.


    Electric power generation from geothermal brine requires, first, bringing the hot brine to the surface and then converting the heat to electric power. Binary conversion schemes were proposed, with the heat transfer between the brine and the working organic fluid taking place in a conventional tube and shell heat exchanger. If the brine is heavily laden with dissolved solids, however, solids buildup on the heat exchanger surfaces leads to a considerable degree of fouling and an accompanying drop in performance is experienced. A possible solution to this problem is the use of a direct contact exchanger with the secondary fluid power cycle. The proposed concept involves the formation of fluid sheets and bells as heat angles. Results of a study concerning the fluid mechanics of such surfaces are given.

  5. Survey of potential process-heat and reject-heat utilization at a Green River nuclear-energy center

    Jensen, C.M.; Sandquist, G.M.


    Potential uses of process heat and reject heat from a nuclear-energy center at Green River, Utah have been investigated. The remoteness of the Green River site would preclude many potential industrial uses for economical reasons such as transportation costs and lack of local markets. Water-consumption requirements would also have serious impact on some applications due to limitations imposed by other contractual agreements upon the water in the region. Several processes were identified which could be considered for the Green River site; including the use of heat to separate bitumens from tar sands, district heating, warming of greenhouses and soil, and the production of fish for game and commercial sales. The size of these industries would be limited and no single process or industry can be identified at this time which could use the full amount of low-temperature reject heat that would be generated at a NEC.

  6. The direct heat measurement of mechanical energy storage metal-organic frameworks.

    Rodriguez, Julien; Beurroies, Isabelle; Loiseau, Thierry; Denoyel, Renaud; Llewellyn, Philip L


    In any process, the heat exchanged is an essential property required in its development. Whilst the work related to structural transitions of some flexible metal-organic frameworks (MOFs) has been quantified and linked with potential applications such as molecular springs or shock absorbers, the heat related to such transitions has never been directly measured. This has now been carried out with MIL-53(Al) using specifically devised calorimetry experiments. We project the importance of these heats in devices such as molecular springs or dampers.

  7. Stability analysis of direct contact heat exchangers subject to system perturbations

    Jacobs, H. R.


    The work deals with the operational stability of a spray column type heat exchanger subject to disturbances typical of those which can occur for geothermal applications. A computer program was developed to solve the one dimensional transient two phase flow problem and it was applied to the design of a spray column. The operation and design of the East Mesa 500kW/sub e/ direct contactor was assessed. It is shown that the heat transfer is governed by the internal resistance of the dispersed phase. The performance is well represented by diffusion of heat within the drops.

  8. Development of a Wind Directly Forced Heat Pump and Its Efficiency Analysis

    Ching-Song Jwo


    Full Text Available The requirements of providing electric energy through the wind-forced generator to the heat pump for water cooling and hot water heating grow significantly by now. This study proposes a new technique to directly adopt the wind force to drive heat pump systems, which can effectively reduce the energy conversion losses during the processes of wind force energy converting to electric energy and electric energy converting to kinetic energy. The operation of heat pump system transfers between chiller and heat that are controlled by a four-way valve. The theoretical efficiency of the traditional method, whose heat pump is directly forced by wind, is 42.19%. The experimental results indicated average value for cool water producing efficiency of 54.38% in the outdoor temperature of 35°C and the indoor temperature of 25°C and the hot water producing efficiency of 52.25% in the outdoor temperature and the indoor temperature both of 10°C. We proposed a method which can improve the efficiency over 10% in both cooling and heating.

  9. Heat Treated AZ61 Magnesium Alloy Obtained by Direct Extrusion and Continuous Rotary Extrusion Process

    Bigaj M.


    Full Text Available The results of studies carried out on the heat treated AZ61 magnesium alloy extruded by two methods, i.e. direct extrusion and continuous rotary extrusion, were presented. As part of the work, parameters of the T6 heat treatment were proposed and aging curves were plotted. The solution heat treatment process was accompanied by the grain growth. During artificial aging, due to the decomposition of solid solution, the β-Mg17Al12 phase was precipitated from the supersaturated α solution. It precipitated in a coagulated form at the grain boundaries and in the form of fine-dispersed plates arranged in a preferred direction relative to the grain orientation. Rods obtained by continuous rotary extrusion, unlike those made by the direct process, exhibited a low degree of texturing and lack of anisotropic properties.

  10. Demonstration of an on-site PAFC cogeneration system with waste heat utilization by a new gas absorption chiller

    Urata, Tatsuo [Tokyo Gas Company, LTD, Tokyo (Japan)


    Analysis and cost reduction of fuel cells is being promoted to achieve commercial on-site phosphoric acid fuel cells (on-site FC). However, for such cells to be effectively utilized, a cogeneration system designed to use the heat generated must be developed at low cost. Room heating and hot-water supply are the most simple and efficient uses of the waste heat of fuel cells. However, due to the short room-heating period of about 4 months in most areas in Japan, the sites having demand for waste heat of fuel cells throughout the year will be limited to hotels and hospitals Tokyo Gas has therefore been developing an on-site FC and the technology to utilize tile waste heat of fuel cells for room cooling by means of an absorption refrigerator. The paper describes the results of fuel cell cogeneration tests conducted on a double effect gas absorption chiller heater with auxiliary waste heat recovery (WGAR) that Tokyo Gas developed in its Energy Technology Research Laboratory.

  11. Market study for direct utilization of geothermal resources by selected sectors of economy


    A comprehensive analysis is presented of industrial markets potential for direct use of geothermal energy by a total of six industry sectors: food and kindred products; tobacco manufactures; textile mill products; lumber and wood products (except furniture); chemicals and allied products; and leather and leather products. A brief statement is presented regarding sectors of the economy and major manufacturing processes which can readily utilize direct geothermal energy. Previous studies on plant location determinants are summarized and appropriate empirical data provided on plant locations. Location determinants and potential for direct use of geothermal resources are presented. The data was gathered through interviews with 30 senior executives in the six sectors of economy selected for study. Probable locations of plants in geothermal resource areas and recommendations for geothermal resource marketing are presented. Appendix A presents factors which impact on industry location decisions. Appendix B presents industry executives interviewed during the course of this study. (MHR)

  12. Numerical Study of Laminar Flow and Convective Heat Transfer Utilizing Nanofluids in Equilateral Triangular Ducts with Constant Heat Flux

    Hsien-Hung Ting


    Full Text Available This study numerically investigates heat transfer augmentation using water-based Al2O3 and CuO nanofluids flowing in a triangular cross-sectional duct under constant heat flux in laminar flow conditions. The Al2O3/water nanofluids with different volume fractions (0.1%, 0.5%, 1%, 1.5%, and 2% and CuO/water nanofluids with various volume fractions (0.05%, 0.16%, 0.36%, 0.5%, and 0.8% are employed, and Reynolds numbers in the range of 700 to 1900 in a laminar flow are considered. The heat transfer rate becomes more remarkable when employing nanofluids. As compared with pure water, at a Peclet number of 7000, a 35% enhancement in the convective heat transfer coefficient, is obtained for an Al2O3/water nanofluid with 2% particle volume fraction; at the same Peclet number, a 41% enhancement in the convective heat transfer coefficient is achieved for a CuO/water nanofluid with 0.8% particle volume concentration. Heat transfer enhancement increases with increases in particle volume concentration and Peclet number. Moreover, the numerical results are found to be in good agreement with published experimental data.

  13. Electric Power Supply of Meat Processing Enterprise through Utilization Heat of Compressor Station Secondary Energy Sources in Main Gasline

    A. Nesenchuk


    Full Text Available The paper considers a structure of power consumption by a meat processing enterprise with indication of specific power consumption norms in accordance with product nomenclature. Schemes for supply of the enterprise with heat and cold through utilization of compressor station secondary energy sources in main gasline have been presented in the paper.

  14. Energy utilization and heat production of embryos from eggs originating from young and old broiler breeder flocks

    Nangsuay, A.; Meijerhof, R.; Ruangpanit, Y.; Kemp, B.; Brand, van den H.


    Two experiments were conducted to study the interaction between breeder age and egg size on the energy utilization (experiment 1) and heat production (experiment 2) of broiler embryos. In experiment 1, a total of 4,800 Ross-308 hatching eggs from 2 breeder ages (29 and 53 wk of age, or young and old

  15. Development of heat and mass balance analysis code in out-of-pile hydrogen production system for HTTR heat utilization system (contract research)

    Inaba, Yoshitomo; Inagaki, Yoshiyuki; Hayashi, Koji; Suyama, Kazumasa [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment


    A heat and mass balance analysis code has been developed to examine test conditions, to investigate transient behavior etc. in the out-of-pile hydrogen production system for the HTTR heat utilization system. The code can analyze temperature, mass and pressure profiles of helium and process gases and behavior of the control system under both static state (case of steady operation) and dynamic state (case of transient operation). This report describes analytical methods, basic equations and constitution of the code, and how to make of the input data, estimate of the analytical results and so on. (author)

  16. Development of heat and mass balance analysis code in out-of-pile hydrogen production system for HTTR heat utilization system (contract research)

    Inaba, Yoshitomo; Inagaki, Yoshiyuki; Hayashi, Koji; Suyama, Kazumasa [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment


    A heat and mass balance analysis code has been developed to examine test conditions, to investigate transient behavior etc. in the out-of-pile hydrogen production system for the HTTR heat utilization system. The code can analyze temperature, mass and pressure profiles of helium and process gases and behavior of the control system under both static state (case of steady operation) and dynamic state (case of transient operation). This report describes analytical methods, basic equations and constitution of the code, and how to make of the input data, estimate of the analytical results and so on. (author)


    Andang Widiharto


    Full Text Available PCMSR (Passive Compact Molten Salt Reactor is one type of Advanced Nuclear Reactors. The PCMSR has benefit charasteristics of very efficient fuel use, high safety charecteristic as well as high thermodinamics efficiency. This is due to its breeding capability, inherently safe characteristic and totally passive safety system. The PCMSR design consists of three module, i.e. reactor module, turbine module and fuel management module. Analysis in performed by parametric calculation of the turbine system to calculate the turbine system efficiency and the hat available for desalination. After that the mass and energi balance of desalination process are calculated to calculate the amount of distillate produced and the amount of feed sea water needed. The turbine module is designed to be operated at maximum temperature cycle of 1373 K (1200 0C and minimum temperature cycle of 333 K (60 0K. The parametric calculation shows that the optimum turbine pressure ratio is 4.3 that gives the conversion efficiency of 56 % for 4 stages turbine and 4 stages compressor and equiped with recuperator. In this optimum condition, the 250 MWe PCMSR turbine system produces 196 MWth of waste heat with the temperature of cooling fluid in the range from 327 K (54 0C to 368 K (92 0C. This waste heat can be utilized for desalination. By using MMED desalination system, this waste heat can be used to produce fresh water (distillate from sea water feed. The amount of the destillate produced is 48663 ton per day by using 15 distillation effects. The performance ratio value is 2.8727 kg/MJ by using 15 distillation effects. Keywords: PCMSR, discharged heat, MMED desalination   PCMSR (Passive Compact Molten Salt Reactor merupakan salah satu tipe dari Reaktor Nuklir Maju. PCMSR memiliki keuntungan berupa penggunaan bahan bakar yang sangat efisisien, sifat keselamatan tinggi dan sekaligus efisiensi termodinamika yang tinggi. Hal ini disebabkan oleh kemampuan pembiakan bahan bakar, sifat

  18. A direct heating model to overcome the edge effect in microplates.

    Lau, Chun Yat; Zahidi, Alifa Afiah Ahmad; Liew, Oi Wah; Ng, Tuck Wah


    Array-based tests in a microplate format are complicated by the regional variation in results of the outer against the inner wells of the plate. Analysis of the evaporation mechanics of sessile drops showed that evaporation rate increase with temperature was due to changes in the heat of vaporization, density and diffusion coefficient. In simulations of direct bottom heating of standard microplates, considerable heat transfer via conduction from the side walls was found to be responsible for lower temperatures in the liquid in wells close to the edge. Applying a two temperature heating mode, 304 K at the side compared to 310 K at the bottom, allowed for a more uniform temperature distribution. Transparency microplates were found to inherently possess immunity to the edge effect problem due to the presence of air between the liquid and solid wall.

  19. An experimental study of a three-phase, direct-contact heat exchanger

    Siqueiros, J.; Bonilla, O. [Unidad Energias No-Convencionales, Div. Energias Alternas e Informatica, Cuernavaca (Mexico)


    An experimental pilot scale three-phase, direct-contact heat exchanger was constructed and tested. Experiments were performed using normal pentane as the dispersed phase and water as the continuous phase. The inlet water temperatures ranged from 75 to 88degC, and the inlet pentane temperatures varied from 23 to 38degC. The volumetric heat transfer coefficient, hold-up and heat flow-rate are functions of pentane mass flow-rate. For high pentane/water volumetric flow ratios flooding was reached. Before reaching flooding conditions, accumulation of liquid pentane at the top of the active volume was found. The experimental volumetric heat transfer coefficient values are on average 30% greater than those estimated with the correlation previously proposed by Jacobs. (Author)

  20. Geothermal potential for commercial and industrial direct heat applications in Salida, Colorado. Final report

    Coe, B.A.; Dick, J.D.; Galloway, M.J.; Gross, J.T.; Meyer, R.T.; Raskin, R.; Zocholl, J.R.


    The Salida Geothermal Prospect (Poncha Hot Springs) was evaluated for industrial and commercial direct heat applications at Salida, Colorado, which is located approximately five miles east of Poncha Hot Springs. Chaffee Geothermal, Ltd., holds the geothermal leases on the prospect and the right-of-way for the main pipeline to Salida. The Poncha Hot Springs are located at the intersection of two major structural trends, immediately between the Upper Arkansas graben and the Sangre de Cristo uplift. Prominent east-west faulting occurs at the actual location of the hot springs. Preliminary exploration indicates that 1600 gpm of geothermal fluid as hot as 250/sup 0/F is likely to be found at around 1500 feet in depth. The prospective existing endusers were estimated to require 5.02 x 10/sup 10/ Btu per year, but the total annual amount of geothermal energy available for existing and future endusers is 28.14 x 10/sup 10/ Btu. The engineering design for the study assumed that the 1600 gpm would be fully utilized. Some users would be cascaded and the spent fluid would be cooled and discharged to nearby rivers. The economic analysis assumes that two separate businesses, the energy producer and the energy distributor, are participants in the geothermal project. The producer would be an existing limited partnership, with Chaffee Geothermal, Ltd. as one of the partners; the distributor would be a new Colorado corporation without additional income sources. Economic evaluations were performed in full for four cases: the Base Case and three alternate scenarios. Alternate 1 assumes a three-year delay in realizing full production relative to the Base Case; Alternate 2 assumes that the geothermal reservoir is of a higher quality than is assumed for the Base Case; and Alternate 3 assumes a lower quality reservoir. 11 refs., 34 figs., 40 tabs.

  1. First experience gained with heat-pump utilization in animal-husbandry plants

    Kuemmritz, W.; Schaeffel, W.


    For cleaning and desinfection of all milk-conducting plant parts, the LPG Tierproduktion at the town of Berlstedt (capacity of 2000 animal stands) needs a daily amount of c. 60 cbm of heated water. Recently 50% of this useful-water requirement has been covered by four small-size heat pumps WW 12 of a water/water configuration. In the heating house, two heat pumps have been installed on top of each other in each case. The circuit plan of the heat-pump facility is demonstrated. The facility operates at open and closed loop, contains two-step rotary pumps and heats useful water to 50-60/sup 0/C. Two heat pumps are operated via shift water throughout the year, the remaining two use brook water in summer and well water in winter as their heat source. 40 t of fuel oil were saved in 1981.

  2. 76 FR 43941 - Energy Conservation Program: Energy Conservation Standards for Direct Heating Equipment


    ... living space. Products intended for use as a heater are often shipped with or designed to be easily.... Specifically, DOE is proposing to change to the definition of ``vented hearth heater,'' a type of direct heating equipment, to clarify the scope of the current exclusion for those vented hearth heaters that are...

  3. Energy efficiency analysis of reactor for torrefaction of biomass with direct heating

    Kuzmina, J. S.; Director, L. B.; Shevchenko, A. L.; Zaichenko, V. M.


    Paper presents energy analysis of reactor for torrefaction with direct heating of granulated biomass by exhaust gases. Various schemes of gas flow through the reactor zones are presented. Performed is a comparative evaluation of the specific energy consumption for the considered schemes. It has been shown that one of the most expensive processes of torrefaction technology is recycling of pyrolysis gases.

  4. Utilization of solar energy. Solar thermal heating systems; Die Waerme vom Himmel holen. Solarthermische Systeme



    Solar thermal power plants collect solar heat by means of collectors. Thus, solar thermal power plants support the heating and supply warm water for the showers. The implementation of solar thermal power plants is interesting especially for the exchange of the heating system as well as in the new house.

  5. Heat treatment of a direct composite resin: influence on flexural strength

    Caroline Lumi Miyazaki


    Full Text Available The purpose of this study was to evaluate the flexural strength of a direct composite, for indirect application, that received heat treatment, with or without investment. One indirect composite was used for comparison. For determination of the heat treatment temperature, thermogravimetric analysis (TGA and differential scanning calorimetry (DSC were performed, considering the initial weight loss temperature and glass transition temperature (Tg. Then, after photoactivation (600 mW/cm² - 40 s, the specimens (10 x 2 x 2 mm were heat-treated following these conditions: 170ºC for 5, 10 or 15 min, embedded or not embedded in investment. Flexural strength was assessed as a means to evaluate the influence of different heat treatment periods and investment embedding on mechanical properties. The data were analyzed by ANOVA and Tukey's test (α = 0.05. TGA showed an initial weight loss temperature of 180ºC and DSC showed a Tg value of 157°C. Heat treatment was conducted in an oven (Flli Manfredi, Italy, after 37°C storage for 48 h. Flexural strength was evaluated after 120 h at 37°C storage. The results showed that different periods and investment embedding presented similar statistical values. Nevertheless, the direct composite resin with treatments presented higher values (178.7 MPa compared to the indirect composite resin (146.0 MPa and the same direct composite submitted to photoactivation only (151.7 MPa. Within the limitations of this study, it could be concluded that the heat treatment increased the flexural strength of the direct composite studied, leading to higher mechanical strength compared to the indirect composite.

  6. High Gain and High Directive of Antenna Arrays Utilizing Dielectric Layer on Bismuth Titanate Ceramics

    F. H. Wee


    Full Text Available A high gain and high directive microstrip patch array antenna formed from dielectric layer stacked on bismuth titanate (BiT ceramics have been investigated, fabricated, and measured. The antennas are designed and constructed with a combination of two-, four-, and six-BiT elements in an array form application on microwave substrate. For gain and directivity enhancement, a layer of dielectric was stacked on the BiT antenna array. We measured the gain and directivity of BiT array antennas with and without the dielectric layer and found that the gain of BiT array antenna with the dielectric layer was enhanced by about 1.4 dBi of directivity and 1.3 dB of gain over the one without the dielectric layer at 2.3 GHz. The impedance bandwidth of the BiT array antenna both with and without the dielectric layer is about 500 MHz and 350 MHz, respectively, which is suitable for the application of the WiMAX 2.3 GHz system. The utilization of BiT ceramics that covers about 90% of antenna led to high radiation efficiency, and small-size antennas were produced. In order to validate the proposed design, theoretical and measured results are provided and discussed.

  7. Open-cycle heat pumps for industrial waste-heat utilization. Project technical report, May 12, 1980-October 10, 1980. Phase I. Feasibility study


    Open-Cycle Industrial Process Heat Pumps (IPHP) are potentially a cost-effective method of utilizing an industrial plant's waste heat. The objective of Phase I of the work was to determine the feasibility of an open-cycle industrial process heat pump. This was accomplished by the evaluation of four potential sites for the installation of open-cycle industrial process heat pump equipment. While it was the original plan to evaluate only three sites, the need for a fourth site became apparent upon completion of studies of the Amstar applications. On the basis of initial screening, it was decided to concentrate on the large waste stream at General Electric's NORYL facility (Selkirk, NY) and a smaller waste stream at the Schoeller Paper Company (Pulaski, NY). These two sites provided opportunities to exploit the features of the open-cyle IPHP without major site constraints. Site studies were conducted to obtain process information such as flow rates, process temperatures, dynamic behavior of the process streams, process control functions, and capacity/time schedules. Information relating to structure and utilities, floor loadings, physical space constraints, electric service, piping runs between equipment location, and waste water tapping points was gathered. These data were analyzed and resulted in the selection of two applications with acceptable thermodynamic performance.

  8. Resource potential of bamboo, challenges and future directions towards sustainable management and utilization in Ethiopia

    Getachew Desalegn


    Full Text Available Aim of study: Bamboo, the fastest growing and high yielding perennial plant of the world has more than 1500 species and 1500 versatile socio-economic uses and ecological services. Ethiopia has two indigenous bamboo species namely Yushania alpina and Oxytenantheria abyssinica, covering about one million ha with a wide distribution. The objective of this paper is to highlight the potential of bamboo resources, challenges including biodeterioration damage, opportunities and future research directions towards its sustainable management and rational utilization.Area of study: Bamboo resources of EthiopiaMaterial and Methods: Reconnaissance survey was done to some parts of the bamboo growing potential areas in Ethiopia besides the literature review. Main results: The bamboo resource, despite its socio-economic and environmental benefits, currently, in most areas has been under high pressure due to land use changes, bamboo mass- flowering, poor processing with low value addition, and damage by biodeteriorating agents (termites, beetles and fungi. The preservative tests on Ethiopian bamboos revealed low natural durability and highlighted the paramount importance of appropriate protection measures such as Tanalith and vehicles used motor oil to increase durability, service life and rational utilization of bamboo-based products and structures as potential alternative construction and furniture material.Research highlights: Therefore, integrated research and development interventions involving different propagation and managements techniques, harvesting season, processing, value addition including proper seasoning and preservation technologies and marketing are recommended to fill the information and technological gaps on sustainable management and rational utilization of this fast growing and multipurpose bamboo resources in Ethiopia.Key words: Bamboo; challenges; management; socio-economic and environmental significance; utilization.

  9. Influence of Different Vortex Generators on Heat Transfer in Direct Air-Cooled Condensers

    ZHOU Guobing; YANG Laishun


    With the capacity of air cooling turbines increasing, the air-cooled steam condenser has been developed to the single fiat tube. Fig.1 shows the studied single-row wavy-finned flat tube. Vortex generators are more and more used in oil and chemical industry, power generation, and refrigeration industry in the heat exchanger. The analyses are performed to investigate the effect of vortex generators on pressure drop and heat transfer of single-row wavy-finned fiat tubes of direct air-cooled condensers.

  10. A consistent direct discretization scheme on Cartesian grids for convective and conjugate heat transfer

    Sato, Norikazu; Takeuchi, Shintaro; Kajishima, Takeo; Inagaki, Masahide; Horinouchi, Nariaki


    A new discretization scheme on Cartesian grids, namely, a "consistent direct discretization scheme", is proposed for solving incompressible flows with convective and conjugate heat transfer around a solid object. The Navier-Stokes and the pressure Poisson equations are discretized directly even in the immediate vicinity of a solid boundary with the aid of the consistency between the face-velocity and the pressure gradient. From verifications in fundamental flow problems, the present method is found to significantly improve the accuracy of the velocity and the wall shear stress. It is also confirmed that the numerical results are less sensitive to the Courant number owing to the consistency between the velocity and pressure fields. The concept of the consistent direct discretization scheme is also explored for the thermal field; the energy equations for the fluid and solid phases are discretized directly while satisfying the thermal relations that should be valid at their interface. It takes different forms depending on the thermal boundary conditions: Dirichlet (isothermal) and Neumann (adiabatic/iso-heat-flux) boundary conditions for convective heat transfer and a fluid-solid thermal interaction for conjugate heat transfer. The validity of these discretizations is assessed by comparing the simulated results with analytical solutions for the respective thermal boundary conditions, and it is confirmed that the present schemes also show high accuracy for the thermal field. A significant improvement for the conjugate heat transfer problems is that the second-order spatial accuracy and numerical stability are maintained even under severe conditions of near-practical physical properties for the fluid and solid phases.

  11. Effect of adaptive abilities on utilities, direct or mediated by mental health?

    Peeters, Yvette; Ranchor, Adelita V.; Vlieland, Thea P. M. Vliet; Stiggelbout, Anne M.


    Background: In cost-utility analyses gain in health can be measured using health state utilities. Health state utilities can be elicited from members of the public or from patients. Utilities given by patients tend to be higher than utilities given by members of the public. This difference is often

  12. Utilizing thermal isostasy to estimate sub-lithospheric heat flow and anomalous crustal radioactivity

    Hasterok, D.; Gard, M.


    While surface heat flow relates to the heat loss through the lithosphere, it can be difficult to quantify and separate the heat produced internally through radiogenic decay from the heat transferred across the base of the lithosphere by mantle convection. In this study, we apply a thermo-isostatic analysis to Australia and estimate the sub-lithospheric and radiogenic heat flow components by employing a simple 1-D conservation of energy model. We estimate an anomalous radiogenic heat production across much of eastern Australia generally accounting for >50 mW m-2, while western Australia appears to have high crustal compositionally corrected elevation, possibly related to chemical buoyancy of the mantle lithosphere. A moderately high sub-lithospheric heat flow (∼40 mW m-2) along the eastern and southeastern coast, including Tasmania, is coincident with locations of Cenozoic volcanism and supports an edge-driven convection hypothesis. However, the pattern of sub-lithospheric heat flow along the margin does not support the existence of hotspot tracks. Thermo-isostatic models such as these improve our ability to identify and quantify crustal from mantle sources of heat loss and add valuable constraints on tectonic and geodynamic models of the continental lithosphere's physical state and evolution.

  13. An analysis of JET fast-wave heating and current drive experiments directly related to ITER

    Bhatnagar, V.P.; Eriksson, L.; Gormezano, C.; Jacquinot, J.; Kaye, A.; Start, D.F.H. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking


    The ITER fast-wave system is required to serve a variety of purposes, in particular, plasma heating to ignition, current profile and burn control and eventually, in conjunction with other schemes, a central non-inductive current drive (CD) for the steady-state operation of ITER. The ICRF heating and current drive data that has been obtained in JET are analyzed in terms of dimensionless parameters, with a view to ascertaining its direct relevance to key ITER requirements. The analysis is then used to identify areas both in physics and technological aspects of ion-cyclotron resonance heating (ICRH) and CD that require further experimentation in ITER-relevant devices such as JET to establish the required data base. (authors). 12 refs., 8 figs.

  14. Directed motion generated by heat bath nonlinearly driven by external noise

    Chaudhuri, J Ray [Department of Physics, Katwa College, Katwa, Burdwan 713 130, West Bengal (India); Barik, D [Indian Association for the Cultivation of Science, Jadavpur, Kolkata 700 032 (India); Banik, S K [Department of Physics, Virginia Polytechnic Institute and State University, Blacksburg, VA 24061-0435 (United States)


    Based on the heat bath system approach where the bath is nonlinearly modulated by an external Gaussian random force, we propose a new microscopic model to study directed motion in the overdamped limit for a nonequilibrium open system. Making use of the coupling between the heat bath and the external modulation as a small perturbation, we construct a Langevin equation with multiplicative noise- and space-dependent dissipation and the corresponding Fokker-Planck-Smoluchowski equation in the overdamped limit. We examine the thermodynamic consistency condition and explore the possibility of observing a phase-induced current as a consequence of state-dependent diffusion and, necessarily, nonlinear driving of the heat bath by the external noise.

  15. Direct numerical simulation of a heat removal configuration for fusion blankets

    Kakarantzas, S.C.; Grecos, A.P.; Vlachos, N.S. [University of Thessaly, Volos (Greece). Department of Mechanical and Industrial Engineering; Sarris, I.E.; Knaepen, B.; Carati, D. [Universite Libre de Bruxelles, Brussels (Belgium). Physique Statistique et Plasmas


    A series of direct numerical simulations (DNS) are performed to study the natural convection heat transfer between concentric cylinders at several Rayleigh and Hartmann numbers. The buoyant flow is driven by the temperature difference between the inner and the outer walls, with the inner wall being at lower temperature, while an external transverse magnetic field is imposed. Both laminar and turbulent flows are observed depending on the magnitude of the Rayleigh and Hartmann numbers. The resulting flow structures of the cases studied were both laminar and turbulent. The results show the 3D nature of turbulence and the tendency of the magnetic field to form narrow Hartmann layers, 3D jets and wakes at specific azimuthal angles. Some particular features of the turbulent regime as well as the heat transfer are also investigated. The magnetic field effect on the convective heat transfer is assessed via the Nusselt number showing that conduction dominates as the Hartmann number increases. (author)

  16. Experimental investigation of a direct driven radial compressor for domestic heat pumps

    Schiffmann, J. [Fischer Engineering Solutions AG, Birkenweg 3, CH-3360 Herzogenbuchsee (Switzerland); Favrat, D. [Ecole Polytechnique Federale de Lausanne, EPFL STI IGM LENI, Station 9, CH-1015 Lausanne (Switzerland)


    The presence of oil in domestic heat pumps is an obstacle toward higher efficiency, particularly for enhanced surface evaporators and for advanced concepts based on two-stage cycles. Very compact direct driven radial compressors supported on oil-free bearings represent a promising alternative. This paper presents the derivation of the specifications, the choice for an appropriate refrigerant fluid and the design of a proof of concept prototype with the various tradeoffs between the impeller characteristics to follow the seasonal heat demand, the bearing and rotordynamics for a stable operation. Heat pump simulation results, the design of the impeller as well as the layout of the experimental facility and first experimental results are presented. An impeller with a tip diameter of 20 mm has been tested at rotational speeds of up to 210 krpm reaching pressure ratios in excess of 3.3 and efficiencies above 78%. The refrigerant chosen for this first experimental approach is HFC 134a. (author)

  17. Liquid/liquid heat exchanger

    Miller, C. G.


    Conceptual design for heat exchanger, utilizing two immiscible liquids with dissimilar specific gravities in direct contact, is more efficient mechanism of heat transfer than conventional heat exchangers with walls or membranes. Concept could be adapted for collection of heat from solar or geothermal sources.

  18. Heat generated by power cables in utility tunnels. Dodonai denryoku cable no ondo yosoku gijutsu no kenkyu

    Ota, K.; Inoue, M.; Takagi, K.; Karikomi, M. (Kajima Corp., Tokyo (Japan))


    In order to investigate the method of expelling the heat generated by the power cable in the utility tunnel, the numerical analysis of model experiment on the heat transfer by natural convection and by radiation was carried out. As the thermal flow from the power cable is positioned in the transition region in the high Rayleigh region where the change takes place from laminar flow to turbid flow, the calculation results may be not always accurate. The visualization of thermal flow using the heat-sensitive liquid crystal was tested to be compared with the calculation results from the generalized simplified marker and cell method (GSMAC) which made it possible to shorten the calculation time. For the analysis of heat transfer by radiation, the radiation energy absorption distribution (READ) method which required short calculation time was employed. The results were as follows: The GSMAC finite element method could be employed in the analysis of this region of natural convention heat transfer. For the visualization of the thermal convection, the microcapsule thermo-sensitive liquid crystal was effective. For the radiation heat transfer analysis of narrow band radiation, the READ was suitable as it gave accurate results within a short period of time. In the construction design, it is important to enhance the radiation between the cable and the wall by separating the power cable. 9 refs., 14 figs., 3 tabs.

  19. Novel metallic alloys as phase change materials for heat storage in direct steam generation applications

    Nieto-Maestre, J.; Iparraguirre-Torres, I.; Velasco, Z. Amondarain; Kaltzakorta, I.; Zubieta, M. Merchan


    Concentrating Solar Power (CSP) is one of the key electricity production renewable energy technologies with a clear distinguishing advantage: the possibility to store the heat generated during the sunny periods, turning it into a dispatchable technology. Current CSP Plants use an intermediate Heat Transfer Fluid (HTF), thermal oil or inorganic salt, to transfer heat from the Solar Field (SF) either to the heat exchanger (HX) unit to produce high pressure steam that can be leaded to a turbine for electricity production, or to the Thermal Energy Storage (TES) system. In recent years, a novel CSP technology is attracting great interest: Direct Steam Generation (DSG). The direct use of water/steam as HTF would lead to lower investment costs for CSP Plants by the suppression of the HX unit. Moreover, water is more environmentally friendly than thermal oils or salts, not flammable and compatible with container materials (pipes, tanks). However, this technology also has some important challenges, being one of the major the need for optimized TES systems. In DSG, from the exergy point of view, optimized TES systems based on two sensible heat TES systems (for preheating of water and superheating vapour) and a latent heat TES system for the evaporation of water (around the 70% of energy) is the preferred solution. This concept has been extensively tested [1, 2, 3] using mainly NaNO3 as latent heat storage medium. Its interesting melting temperature (Tm) of 306°C, considering a driving temperature difference of 10°C, means TES charging steam conditions of 107 bar at 316°C and discharging conditions of 81bar at 296°C. The average value for the heat of fusion (ΔHf) of NaNO3 from literature data is 178 J/g [4]. The main disadvantage of inorganic salts is their very low thermal conductivity (0.5 W/m.K) requiring sophisticated heat exchanging designs. The use of high thermal conductivity eutectic metal alloys has been recently proposed [5, 6, 7] as a feasible alternative. Tms

  20. Heat Loss Measurements in Buildings Utilizing a U-value Meter

    Sørensen, Lars Schiøtt

    the best basis for upgrading the energy performance, it is important to measure the heat losses at different locations on a building facade, in order to optimize the energy performance. The author has invented a U-value meter, enabling measurements of heat transfer coefficients. The meter has been used...

  1. A hymenopterists’ guide to the Hymenoptera Anatomy Ontology: utility, clarification, and future directions

    Katja Seltmann


    Full Text Available Hymenoptera exhibit an incredible diversity of phenotypes, the result of ~240 million years of evolution and the primary subject of more than 250 years of research. Here we describe the history, development, and utility of the Hymenoptera Anatomy Ontology (HAO and its associated applications. These resources are designed to facilitate accessible and extensible research on hymenopteran phenotypes. Outreach with the hymenopterist community is of utmost importance to the HAO project, and this paper is a direct response to questions that arised from project workshops. In a concerted attempt to surmount barriers of understanding, especially regarding the format, utility, and development of the HAO, we discuss the roles of homology, “preferred terms”, and “structural equivalency”. We also outline the use of Universal Resource Identifiers (URIs and posit that they are a key element necessary for increasing the objectivity and repeatability of science that references hymenopteran anatomy. Pragmatically, we detail a mechanism (the “URI table” by which authors can use URIs to link their published text to the HAO, and we describe an associated tool (the “Analyzer” to derive these tables. These tools, and others, are available through the HAO Portal website ( We conclude by discussing the future of the HAO with respect to digital publication, cross-taxon ontology alignment, the advent of semantic phenotypes, and community-based curation.

  2. EntrezAJAX: direct web browser access to the Entrez Programming Utilities

    Pallen Mark J


    Full Text Available Abstract Web applications for biology and medicine often need to integrate data from Entrez services provided by the National Center for Biotechnology Information. However, direct access to Entrez from a web browser is not possible due to 'same-origin' security restrictions. The use of "Asynchronous JavaScript and XML" (AJAX to create rich, interactive web applications is now commonplace. The ability to access Entrez via AJAX would be advantageous in the creation of integrated biomedical web resources. We describe EntrezAJAX, which provides access to Entrez eUtils and is able to circumvent same-origin browser restrictions. EntrezAJAX is easily implemented by JavaScript developers and provides identical functionality as Entrez eUtils as well as enhanced functionality to ease development. We provide easy-to-understand developer examples written in JavaScript to illustrate potential uses of this service. For the purposes of speed, reliability and scalability, EntrezAJAX has been deployed on Google App Engine, a freely available cloud service. The EntrezAJAX webpage is located at

  3. A Limited Submuscular Direct-to-Implant Technique Utilizing AlloMax

    Michal Brichacek, MD


    Full Text Available Background:. This study evaluates a novel limited submuscular direct-to-implant technique utilizing AlloMax where only the upper few centimeters of the implant is covered by the pectoralis, whereas the majority of the implant including the middle and lower poles are covered by acellular dermal matrix. Methods:. The pectoralis muscle is released off its inferior and inferior-medial origins and allowed to retract superiorly. Two sheets of AlloMax (6 × 16 cm are sutured together and secured to the inframammary fold, serratus fascia, and the superiorly retracted pectoralis. Thirty-seven breasts in 19 consecutive patients with follow-up at 6 months were reviewed. Results:. Nineteen consecutive patients with 37 reconstructed breasts were studied. Average age was 50 years, average BMI was 24.3. Ptosis ranged from grade 0–III, and average cup size was B (range, A–DDD. Early minor complications included 1 seroma, 3 minor postoperative hematomas managed conservatively, and 3 minor wound healing problems. Three breasts experienced mastectomy skin flap necrosis and were managed with local excision. There were no cases of postoperative infection, red breast, grade III/IV capsular contractures, or implant loss. A single patient complained of animation postoperatively. One patient desired fat grafting for rippling. Conclusions:. The limited submuscular direct-to-implant technique utilizing AlloMax appears to be safe with a low complication rate at 6 months. This technique minimizes the action of the pectoralis on the implant, reducing animation deformities but still providing muscle coverage of the upper limit of the implant. Visible rippling is reduced, and a vascularized bed remains for fat grafting of the upper pole if required.

  4. Direct Release of Test Results to Patients Increases Patient Engagement and Utilization of Care.

    Francesca Pillemer

    Full Text Available An important focus for meaningful use criteria is to engage patients in their care by allowing them online access to their health information, including test results. There has been little evaluation of such initiatives. Using a mixed methods analysis of electronic health record data, surveys, and qualitative interviews, we examined the impact of allowing patients to view their test results via patient portal in one large health system. Quantitative data were collected for new users and all users of the patient portal. Qualitative interviews occurred with patients who had received an HbA1c or abnormal Pap result. Survey participants were active patient portal users. Our main measures were patient portal usage, factors associated with viewing test results and utilizing care, and patient and provider experiences with patient portal and direct release. Usage data show 80% of all patient portal users viewed test results during the year. Of survey respondents, 82.7% noted test results to be a very useful feature and 70% agreed that patient portal has made their provider more accessible to them. Interviewed patients reported feeling they should have direct access to test results and identified the ability to monitor results over time and prepare prior to communicating with a provider as benefits. In interviews, both patients and physicians reported instances of test results leading to unnecessary patient anxiety. Both groups noted the benefits of results released with provider interpretation. Quantitative data showed patient utilization to increase with viewing test results online, but this effect is mitigated when results are manually released by physicians. Our findings demonstrate that patient portal access to test results was highly valued by patients and appeared to increase patient engagement. However, it may lead to patient anxiety and increase rates of patient visits. We discuss how such unintended consequences can be addressed and larger

  5. Evaluation of Waste Heat Recovery and Utilization from Residential Appliances and Fixtures

    Tomlinson, John J [ORNL; Christian, Jeff [Oak Ridge National Laboratory (ORNL); Gehl, Anthony C [ORNL


    Executive Summary In every home irrespective of its size, location, age, or efficiency, heat in the form of drainwater or dryer exhaust is wasted. Although from a waste stream, this energy has the potential for being captured, possibly stored, and then reused for preheating hot water or air thereby saving operating costs to the homeowner. In applications such as a shower and possibly a dryer, waste heat is produced at the same time as energy is used, so that a heat exchanger to capture the waste energy and return it to the supply is all that is needed. In other applications such as capturing the energy in drainwater from a tub, dishwasher, or washing machine, the availability of waste heat might not coincide with an immediate use for energy, and consequently a heat exchanger system with heat storage capacity (i.e. a regenerator) would be necessary. This study describes a two-house experimental evaluation of a system designed to capture waste heat from the shower, dishwasher clothes washer and dryer, and to use this waste heat to offset some of the hot water energy needs of the house. Although each house was unoccupied, they were fitted with equipment that would completely simulate the heat loads and behavior of human occupants including operating the appliances and fixtures on a demand schedule identical to Building American protocol (Hendron, 2009). The heat recovery system combined (1) a gravity-film heat exchanger (GFX) installed in a vertical section of drainline, (2) a heat exchanger for capturing dryer exhaust heat, (3) a preheat tank for storing the captured heat, and (4) a small recirculation pump and controls, so that the system could be operated anytime that waste heat from the shower, dishwasher, clothes washer and dryer, and in any combination was produced. The study found capturing energy from the dishwasher and clothes washer to be a challenge since those two appliances dump waste water over a short time interval. Controls based on the status of the

  6. Evaluation of Waste Heat Recovery and Utilization from Residential Appliances and Fixtures

    Tomlinson, John J [ORNL; Christian, Jeff [Oak Ridge National Laboratory (ORNL); Gehl, Anthony C [ORNL


    Executive Summary In every home irrespective of its size, location, age, or efficiency, heat in the form of drainwater or dryer exhaust is wasted. Although from a waste stream, this energy has the potential for being captured, possibly stored, and then reused for preheating hot water or air thereby saving operating costs to the homeowner. In applications such as a shower and possibly a dryer, waste heat is produced at the same time as energy is used, so that a heat exchanger to capture the waste energy and return it to the supply is all that is needed. In other applications such as capturing the energy in drainwater from a tub, dishwasher, or washing machine, the availability of waste heat might not coincide with an immediate use for energy, and consequently a heat exchanger system with heat storage capacity (i.e. a regenerator) would be necessary. This study describes a two-house experimental evaluation of a system designed to capture waste heat from the shower, dishwasher clothes washer and dryer, and to use this waste heat to offset some of the hot water energy needs of the house. Although each house was unoccupied, they were fitted with equipment that would completely simulate the heat loads and behavior of human occupants including operating the appliances and fixtures on a demand schedule identical to Building American protocol (Hendron, 2009). The heat recovery system combined (1) a gravity-film heat exchanger (GFX) installed in a vertical section of drainline, (2) a heat exchanger for capturing dryer exhaust heat, (3) a preheat tank for storing the captured heat, and (4) a small recirculation pump and controls, so that the system could be operated anytime that waste heat from the shower, dishwasher, clothes washer and dryer, and in any combination was produced. The study found capturing energy from the dishwasher and clothes washer to be a challenge since those two appliances dump waste water over a short time interval. Controls based on the status of the

  7. Layered thermal metamaterials for the directing and harvesting of conductive heat

    P. R. Bandaru


    Full Text Available The utility of a metamaterial, assembled from two layers of nominally isotropic materials, for thermal energy re-orientation and harvesting is examined. A study of the underlying phenomena related to heat flux manipulation, exploiting the anisotropy of the thermal conductivity tensor, is a focus. The notion of the assembled metamaterial as an effective thermal medium forms the basis for many of these investigations and will be probed. An overarching aim is to implement in such thermal metamaterials, functionalities well known from light optics, such as reflection and refraction, which in turn may yield insights on efficient thermal lensing. Consequently, the harness and dissipation of heat, which are for example, of much importance in energy conservation and improving electrical device performance, may be accomplished. The possibilities of energy harvesting, through exploiting anisotropic thermopower in the metamaterials is also examined. The review concludes with a brief survey of the outstanding issues and insights needed for further progress.

  8. Rapid heat-flowing surveying of geothermal areas, utilizing individual snowfalls as calorimeters

    White, Donald E.


    Local differences in rate of heat transfer in vapor and by conduction through the ground in hot spring areas are difficult and time-consuming to measure quantitatively. Individual heavy snowfalls provide a rapid low-cost means of measuring total heat flow from such ground. After a favorable snowfall (heavy, brief duration, little wind, air temperature near 0°C), contacts between snow-covered and snow-free ground are mapped on a suitable base. Each mapped contact, as time elapses after a specific snowfall, is a heat-flow contour representing a decreasing rate of flow. Calibration of each mapped contact or snow line is made possible by the fact that snow remains on insulated surfaces (such as the boardwalks of Yellowstone's thermal areas) long after it has melted on adjacent warm ground. Heat-flow contours mapped to date range from 450 to 5500 μcal/cm2 sec, or 300 to 3700 times the world average of conductive heat flow. The very high rates of heat flow (2000 to > 10,000 μcal/cm2 sec) are probably too high, and the lower heat flows determinable by the method (2 sec) may be too low. Values indicated by the method are, however, probably within a factor of 2 of the total conductive and convective heat flow. Thermal anomalies from infrared imagery are similar in shape to heat-flow contours of a test area near Old Faithful geyser. Snowfall calorimetry provides a rapid means for evaluating the imagery and computer-derived products of the infrared data in terms of heat flow.

  9. Evaluation of Technical and Utility Programmatic Challenges With Residential Forced-Air Integrated Space/Water Heat Systems

    Kingston, Tim [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States); Vadnal, Hillary [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States); Scott, Shawn [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States); Kalensky, Dave [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States)


    This multi-unit field demonstration of combined space and water heating (combi) systems was conducted to help document combi system installation and performance issues that needed to be addressed through research. The objective of the project was to put commercialized forced-air tankless combi units into the field through local contractors that were trained by manufacturers and GTI staff under the auspices of utility-implemented ETPs.

  10. Evaluation of Technical and Utility Programmatic Challenges With Residential Forced-Air Integrated Space/Water Heat Systems

    Kingston, Tim [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States); Vadnal, Hillary [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States); Scott, Shawn [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States); Kalensky, Dave [Partnership for Advanced Residential Retrofit, Des Plaines, IL (United States)


    This multi-unit field demonstration of combined space and water heating (combi) systems was conducted to help document combi system installation and performance issues that needed to be addressed through research. The objective of the project was to put commercialized forced-air tankless combi units into the field through local contractors that were trained by manufacturers and GTI staff under the auspices of utility-implemented ETPs.

  11. Heat Flux and Wall Temperature Estimates for the NASA Langley HIFiRE Direct Connect Rig

    Cuda, Vincent, Jr.; Hass, Neal E.


    An objective of the Hypersonic International Flight Research Experimentation (HIFiRE) Program Flight 2 is to provide validation data for high enthalpy scramjet prediction tools through a single flight test and accompanying ground tests of the HIFiRE Direct Connect Rig (HDCR) tested in the NASA LaRC Arc Heated Scramjet Test Facility (AHSTF). The HDCR is a full-scale, copper heat sink structure designed to simulate the isolator entrance conditions and isolator, pilot, and combustor section of the HIFiRE flight test experiment flowpath and is fully instrumented to assess combustion performance over a range of operating conditions simulating flight from Mach 5.5 to 8.5 and for various fueling schemes. As part of the instrumentation package, temperature and heat flux sensors were provided along the flowpath surface and also imbedded in the structure. The purpose of this paper is to demonstrate that the surface heat flux and wall temperature of the Zirconia coated copper wall can be obtained with a water-cooled heat flux gage and a sub-surface temperature measurement. An algorithm was developed which used these two measurements to reconstruct the surface conditions along the flowpath. Determinations of the surface conditions of the Zirconia coating were conducted for a variety of conditions.

  12. Experimental analysis of heat and mass transfer phenomena in a direct contact evaporative cooling tower

    Lemouari, M. [Department of Processes Engineering, Faculty of Sciences and Engineering, University of Bejaia (Algeria); Boumaza, M. [Department of Chemical Engineering, College of Engineering - King Saud University, P.O. Box 800, Riyadh (Saudi Arabia); Kaabi, A. [Department of Genie Climatique, Faculty of Engineering, University of Constantine, Constantine (Algeria)


    This paper deals with an experimental analysis of simultaneous heat and mass transfer phenomena between water and air by direct contact in a packed cooling tower. The tower is filled with a ''VGA.'' (Vertical Grid Apparatus) type packing. The packing is 0.42 m high and consists of four (04) galvanised sheets having a zigzag form, between which are disposed three (03) metallic vertical grids in parallel with a cross-sectional test area of 0.15 m x 0.148 m. This study investigates the effect of the air and water flow rates on the global heat and mass transfer coefficient as well as the evaporation rate of water into the air stream, for different inlet water temperatures. Two operating regimes were observed during the air/water contact inside the tower, a Pellicular Regime (PR) and a Bubble and Dispersion Regime (BDR). These two regimes can determine the best way to promote the heat and mass transfer phenomena in such device. The BDR regime seems to be more efficient than the Pellicular Regime, as it enables to achieve relatively higher values of the global heat and mass transfer coefficient and larger water evaporation rates. The comparison between the obtained results and some of those available in the literature for other types of packing indicates that this type possesses good heat and mass transfer characteristics. (author)

  13. Heat storage characteristics of latent microcapsules using hot air bubbles by direct contact heat exchange; Onshitsu kihogun to sennetsu microcapsule tono chokusetsu sesshohku kokan ni yoru chikunetsu tokusei

    Nakagawa, K.; Sugiura, T. [Toyohashi University of Technology, Aichi (Japan)


    This paper has dealt with the heat storage characteristics of fine microcapsules packed with latent heat storage material in the water layer. The heat storage operation to the latent microcapsules was carried out using hot air bubbles by direct contact heat exchange. The microcapsule consists of n-paraffin as a core latent-heat storage material and melamine resin as a coating substance. The relation of the completion time of latent-heat storage to some parameters was examined experimentally. The non-dimensional correlation equations for the completion time of latent-heat storage process had were derived in terms of the ratio of water layer height to diameter of microcapsule, Reynolds number for air flow, Stefan number and modified Stefan number for absolute humidity of flowing air. (author)

  14. Parametric Limits of Efficient Use of a Centrifugal Water Atomizer in Contact Waste-Gas Heat-Utilization Units

    Bezrodnyi, M. K.; Rachinskii, A. Yu.; Barabash, P. A.; Goliyad, N. N.


    The relation for the limiting temperature of water heating in a contact gas-droplet-type apparatus with a centrifugal atomizer has been determined experimentally in relation to the conditions of utilization of heat of power plant waste-gases. Investigations were carried out in the range of excess water pressures in front of the atomizer 0.2-0.6 MPa and of the volume fraction of steam in the vapor-gas mixture at the inlet of the apparatus from 0.02 to 0.45. The possibility of using the obtained dependence for calculating the limiting values of the vapor-gas flow parameters that limit the range of efficient operation of the contact apparatus with steam condensation and in the absence of heated liquid droplet evaporation is shown.

  15. Direct initiation of gaseous detonation via radiative heating of microparticles volumetrically suspended in the gas

    Efremov, V. P.; Ivanov, M. F.; Kiverin, A. D.; Yakovenko, I. S.


    We propose a new conceptual approach for direct detonation initiation in the gaseous mixtures seeded with micro particles via the radiative heating from the external energy source. The basic mechanisms of energy absorption, ignition and detonation formation are analyzed numerically on the example of hydrogen-oxygen mixture. Obtained data is very promising and allows us to formulate conditions for the source power to ignite detonation in certain system geometry.

  16. Antiepileptic drugs prescription utilization behavior and direct costs of treatment in a national hospital of India

    Ahsan Haroon


    Full Text Available Background and Objectives: The present study evaluated the direct costs of active epilepsy and looked at the pattern of drug prescription and utilization in epileptic patients visiting the neuroscience centre of a national hospital of India. Materials and Methods: A total of 134 epileptic patients were studied over a period of 4 months. Patients demography, commonly prescribed antiepileptic drugs (AEDs, socioeconomic status, direct costs, response ratio (RR for newer drugs, and quality of life (QOLIE-10 was evaluated. Results and Discussion: We found a higher percentage of male patients (67.9% as compared with females. Most of the patients were in the age group 11-30 years and majority of them (39.6% belonged to lower middle group. A higher percentage (68.7 of drugs was prescribed as polytherapy. Higher monthly cost was observed for some of the newer AEDs including the lamotrigine, levetiracetam, and lacosamide as compared with older drugs. Among the newer drugs, clobazam had the lowest cost. RR was calculated for 12 patients out of which 8 had a RR < −0.50. The QOL domains, following conventional or newer drugs, were not much affected. Conclusion: The study indicates an increasing trend toward clinical usage of newer AEDs, increasing trend of poly-therapy with significant escalations in the cost of therapy.

  17. Heat Loss Measurements in Buildings Utilizing a U-value Meter

    Sørensen, Lars Schiøtt

    Heating of buildings in Denmark accounts for approximately 40% of the entire national energy consumption. For this reason, a reduction of heat losses from building envelopes are of great importance in order to reach the Bologna CO2 emission reduction targets. Upgrading of the energy performance...... of buildings is a topic of huge global interest these years. Not only heating in the temperate and arctic regions are important, but also air conditioning and mechanical ventilation in the tropical countries contribute to an enormous energy consumption and corresponding CO2 emission. In order to establish...... of energy for heating and cooling of buildings. There is a huge energy-saving potential in this area for reducing both the global climate problems as well as economy challenges. In fact, global energy efficiency can be obtained in two ordinary ways. One way is to improve the energy production and supply...

  18. Parabolic solar cooker: Cooking with heat pipe vs direct spiral copper tubes

    Craig, Omotoyosi O.; Dobson, Robert T.


    Cooking with solar energy has been seen by many researchers as a solution to the challenges of poverty and hunger in the world. This is no exception in Africa, as solar coking is viewed as an avenue to eliminate the problem of food insecurity, insufficient energy supply for household and industrial cooking. There are several types of solar cookers that have been manufactured and highlighted in literature. The parabolic types of solar cookers are known to reach higher temperatures and therefore cook faster. These cookers are currently being developed for indoor cooking. This technology has however suffered low cooking efficiency and thus leads to underutilization of the high heat energy captured from the sun in the cooking. This has made parabolic solar cookers unable to compete with other conventional types of cookers. Several methods to maximize heat from the sun for indirect cooking has been developed, and the need to improve on them of utmost urgency. This paper investigates how to optimize the heat collected from the concentrating types of cookers by proposing and comparing two types of cooking sections: the spiral hot plate copper tube and the heat pipe plate. The system uses the concentrating solar parabolic dish technology to focus the sun on a conical cavity of copper tubes and the heat is stored inside an insulated tank which acts both as storage and cooking plate. The use of heat pipes to transfer heat between the oil storage and the cooking pot was compared to the use of a direct natural syphon principle which is achieved using copper tubes in spiral form like electric stove. An accurate theoretical analysis for the heat pipe cooker was achieved by solving the boiling and vaporization in the evaporator side and then balancing it with the condensation and liquid-vapour interaction in the condenser part while correct heat transfer, pressure and height balancing was calculated in the second experiment. The results show and compare the cooking time, boiling

  19. Direct Measurements of Hydrothermal Heat Output at Juan de Fuca Ridge

    Germanovich, L. N.; di Iorio, D.; Genc, G.; Hurt, R. S.; Lowell, R. P.; Holden, J. F.; Butterfield, D. A.; Olson, E. J.


    Heat output and fluid flow are key parameters for characterizing seafloor hydrothermal systems at oceanic spreading centers. In particular, they are essential for examining partition of heat and geochemical fluxes between discrete and diffuse flow components. Hydrothermal heat output also constrains permeability of young oceanic crust and thickness of the conductive boundary layer separating hydrothermal circulation from the underlying magmatic heat source. Over the past several years, we have deployed a number of relatively simple devices to make direct measurements of focused and diffuse flow. Most recently, we have used cup anemometer and turbine flow meters to measure fluid flow and heat flux at individual high-temperature vents and diffuse flow sites. The turbine flow meter (Figure 1) includes a titanium rotor assembly housed within a stainless steel tube and supported by sapphire bearings. The device can be used at different seafloor settings for measurements of both diffuse and focused flow. The spin of the rotor blades is videotaped to acquire the angular velocity, which is a function of the flow rate determined through calibration. We report data obtained during four cruises to the Main Endeavor and High Rise vent fields, Juan de Fuca Ridge (JdFR), between 2007 and 2009. Overall more than 50 successful measurements of heat flow have been made on a variety of high-, medium-, and low-temperature hydrothermal sites on the Endeavor, Mothra, and High Rise structures. For example, the velocity of diffuse flow at Endeavor ranged from ~1 to ~10 cm/sec. The flow velocity from black smokers varied from ~10 cm/sec to ~1 m/sec, which appears to be similar to EPR 9°N. Typical measurements of heat flux obtained at JdFR ranged from ~1 kW for diffuse flow to ~1 MW for black smokers. Although it is difficult to extrapolate the data and obtain the integrated heat output for a vent field on JdFR, the data are used to characterize the heat fluxes from individual vent

  20. ASPEN+ and economic modeling of equine waste utilization for localized hot water heating via fast pyrolysis

    ASPEN Plus based simulation models have been developed to design a pyrolysis process for the on-site production and utilization of pyrolysis oil from equine waste at the Equine Rehabilitation Center at Morrisville State College (MSC). The results indicate that utilization of all available Equine Reh...

  1. Utilization of a heat pump in pig breeding for energy saving and climate and ammonia control

    Riva, Giovanni; Pedretti, Ester Foppa [Ancona Univ., Ancona (Italy); Fabbri, Claudio [Centro Ricerche Produzioni Animali, Reggio Emilia (Italy)


    The performance of three heating systems was analysed in closed-cycle pig farm (farrowing and weaning section). Three adjoining rooms were heated using one of the following systems: a reversible air to air heat pump (HP) for both heating and cooling; a standard liquid petroleum gas (LPG) boiler for heating coupled with mechanical ventilation for summer cooling; and natural ventilation with emergency convective heating. Their energy consumption and influence on production parameters were compared. Fifteen groups of sow and their litters were housed in succession in each room from the end of pregnancy through weaning (5 cycles). Temperature and humidity and production parameters (i.e. feed conversion index) were measured for each cycle and room. In the case of HP, the ammonia emissions produced in, and extracted from, the breeding room were also determined. The HP consistently maintained both temperature and humidity around optimal values (average 26.2degC and 64.2% relative humidity) and allowed primary energy savings of 11% compared with the LPG heater. The piglets weaned in the HP room showed better growth performance. Finally, the air processed by the HP contained less than half the ammonia concentrations recorded in the naturally ventilated room. (Author)

  2. Laser heating of a cavity versus a plane surface for metal targets utilizing photothermal deflection measurements

    Jeong, S. H.; Greif, R.; Russo, R. E.


    The effects of a cylindrical cavity in a metal surface on the energy coupling of a laser beam with the solid were investigated by using a photothermal deflection technique. The photothermal deflection of a probe beam over the cavity was measured while the bottom of the cavity was heated with a Nd-YAG laser with a wavelength of 1064 nm. Cavities in three different materials and with two different aspect ratios were used for the experiment. Temperature distributions in the solid and the surrounding air were computed numerically and used to calculate photothermal deflections for cavity heating and for plane surface heating. Reflection of the heating laser beam inside the cavity increased the photothermal deflection amplitude significantly with larger increases for materials with larger thermal diffusivity. The computed photothermal deflections agreed more closely with the experimental results when reflection of the heating laser beam inside the cavity was included in the numerical model. The overall energy coupling between a heating laser and a solid is enhanced by a cavity.

  3. Open-cycle magnetohydrodynamic power plant based upon direct-contact closed-loop high-temperature heat exchanger

    Berry, Gregory F.; Minkov, Vladimir; Petrick, Michael


    A magnetohydrodynamic (MHD) power generating system in which ionized combustion gases with slag and seed are discharged from an MHD combustor and pressurized high temperature inlet air is introduced into the combustor for supporting fuel combustion at high temperatures necessary to ionize the combustion gases, and including a heat exchanger in the form of a continuous loop with a circulating heat transfer liquid such as copper oxide. The heat exchanger has an upper horizontal channel for providing direct contact between the heat transfer liquid and the combustion gases to cool the gases and condense the slag which thereupon floats on the heat transfer liquid and can be removed from the channel, and a lower horizontal channel for providing direct contact between the heat transfer liquid and pressurized air for preheating the inlet air. The system further includes a seed separator downstream of the heat exchanger.

  4. Putting politics into perspective. A Study of the Implementation of EU public utilities directives

    Berglund, S.K.


    In the area of public utilities, the member states of the European Union (EU) have agreed on ambitious policies to open up markets for competition and to regulate these markets. To have the expected effect, these policies have to be implemented effectively. In this book it is demonstrated that this is problematic; difficulties appear already in the first step of transposing the directives into national legislation. The analysis of an original quantitative data set including all public utilities directives and their transposition in five member states - the Netherlands, Germany, the United Kingdom, Spain, and Greece - shows that almost two thirds of all cases are transposed after the deadlines that are included in the directives. In order to explain problems with the implementation of EU policies, three main types of variables are used in the literature, namely political, administrative, and institutional variables. In recent literature on transposition the focus is on political explanations. However, despite a surge of attention for transposition there is no consensus regarding which type of variable is most important. In this book the focus on political variables is addressed. It is examined if such a focus is well founded, and whether and how different types of variables combine in order to produce the transposition outcome. To this end, a novel approach is taken by developing a theoretical framework that applies implementation theory to transposition. In this framework the three types of variables in the literature on transposition are combined in one coherent framework. The theoretical framework is applied mainly in a case study setting. The transposition of two packages of directives in the fields of telecommunications and energy in the Netherlands, Germany and Greece is studied in detail. The main conclusion is that political factors play an important role for the timeliness of transposition, but that a number of 'mediating' variables of

  5. HEMS technique for heat-harm control and geo-thermal utilization in deep mines

    Pingye Guo; Guolong Zhu; Manchao He


    With the increasing exploitation scope and intensity, the shallow resources would be exhausted in the future;and the deep mining will become an essential choice. In deep tunnel engineering, the heat-harm becomes one of the main barriers. Investigations on high temperature coal mine have been done in Northern China, with the constructing of three models of high temperature mines suffering heat-harm, at the Jiahe mine, Sanhejian mine and Zhangshuanglou mine. The domestic and abroad cooling technologies of the mine respectively are also summarized after comparatively analyzing the advantages and disadvantages of each technology. Finally, we find that the high temperature exchange machinery system (HEMS) technology that use mine discharge as the cold source, is excellent to heat-harm control in deep mines. Taking the Jiahe coal mine as an example, we systematically introduce this technology by disposing three main workstations. HEMS technology with its operations and functions in different exploitation levels are accomplished, including the extraction of refrigerating output, the transportation of chilled water by closed circulation line, the decompression of circulation lines and equipment by pressure transformation machine, and the heat exchange and cooling of workplace by heat exchange between wind stream and the chilled water. The exchanged heat source from the workplace is taken to ground heating by the circulating water which acts as a carrier. It shows that the HEMS-technology benefit in environment protection and emission reduction. Results of this project illustrate that it is efficient in heat-harm control with the temperature decrease of the workplace down to 26–29 ?C, and being 4–6 ?C lower than the original, and the relative humidity 5%–15%lower than before. It greatly improves the working environment of underground workplace suffering heat-harm of high tem-perature and high humidity. In addition, by the extracting of deep geothermal energy, ground

  6. Geothermal direct-heat utilization assistance. Quarterly report, July--September 1993


    This report details activities from July through September 1993, Topics addressed are: Technical Assistance; Research and Development Activities; Technology Transfer; Geothermal Progress Monitor; and Personnel.

  7. Direct utilization of geothermal energy: a layman's guide. Geothermal Resources Council special report No. 8

    Anderson, D.N.; Lund, J.W. (eds.)


    The following subjects are covered: nature and distribution of geothermal energy; exploration, confirmation, and evaluation of the resource; reservoir development and management; utilization; economics of direct-use development; financing direct-use projects; and legal, institutional, and environmental aspects. (MHR)

  8. Heat release characteristics of middle temperature latent heat storage vessel by means of direct contact heat exchange method; Chokusetsu sesshoku netsu kokanho wo mochiita chuondo sennetsu chikunetsuso no honetsu tokusei

    Inaba, H.; Horibe, A.; Ozaki, K. [Okayama University, Okayama (Japan). Faculty of Engineering; Emoto, K. [Okayama University, Okayama (Japan); Kakiuchi, H. [Mitsubishi Chemical Corp., Tokyo (Japan)


    Experiment has been performed of heat transfer characteristics of the middle temperature latent heat storage system of the direct-contact heat transfer by using m-E (meso-Erythritol, melting point of 119 degree C, latent heat of 375 kJ/kg) droplets as a latent heat storage material and silicone oil as a heat transfer medium. In the present study the liquid m-E was injected into the heat transfer medium through a circular nozzle. The m-E droplets changed from liquid to solid phase during falling in the heat transfer medium at low temperature. From the measuring results of m-E droplet diameter, falling velocity, and solidification rate, the nondimensional empirical equations of the arithmetic mean diameter of the droplets and falling velocity, the solidification rate and the overall heat transfer coefficient were derived as a function of the characteristic arithmetic mean diameter, the terminal velocity, temperature and physical properties. (author)

  9. Effects of Latent Heating on Atmospheres of Brown Dwarfs and Directly Imaged Planets

    Tan, Xianyu; Showman, Adam P.


    The growing number of observations of brown dwarfs (BDs) has provided evidence for strong atmospheric circulation on these objects. Directly imaged planets share similar observations and can be viewed as low-gravity versions of BDs. Vigorous condensate cycles of chemical species in their atmospheres are inferred by observations and theoretical studies, and latent heating associated with condensation is expected to be important in shaping atmospheric circulation and influencing cloud patchiness. We present a qualitative description of the mechanisms by which condensational latent heating influences circulation, and then illustrate them using an idealized general circulation model that includes a condensation cycle of silicates with latent heating and molecular weight effect due to the rainout of the condensate. Simulations with conditions appropriate for typical T dwarfs exhibit the development of localized storms and east-west jets. The storms are spatially inhomogeneous, evolving on a timescale of hours to days and extending vertically from the condensation level to the tropopause. The fractional area of the BD covered by active storms is small. Based on a simple analytic model, we quantitatively explain the area fraction of moist plumes and show its dependence on the radiative timescale and convective available potential energy (CAPE). We predict that if latent heating dominates cloud formation processes, the fractional coverage area of clouds decreases as the spectral type goes through the L/T transition from high to lower effective temperature. This is a natural consequence of the variation of the radiative timescale and CAPE with the spectral type.

  10. Directly connected heat exchanger tube section and coolant-cooled structure

    Chainer, Timothy J.; Coico, Patrick A.; Graybill, David P.; Iyengar, Madhusudan K.; Kamath, Vinod; Kochuparambil, Bejoy J.; Schmidt, Roger R.; Steinke, Mark E.


    A method is provided for fabricating a cooling apparatus for cooling an electronics rack, which includes an air-to-liquid heat exchanger, one or more coolant-cooled structures, and a tube. The heat exchanger is associated with the electronics rack and disposed to cool air passing through the rack, includes a plurality of coolant-carrying tube sections, each tube section having a coolant inlet and outlet, one of which is coupled in fluid communication with a coolant loop to facilitate flow of coolant through the tube section. The coolant-cooled structure(s) is in thermal contact with an electronic component(s) of the rack, and facilitates transfer of heat from the component(s) to the coolant. The tube connects in fluid communication one coolant-cooled structure and the other of the coolant inlet or outlet of the one tube section, and facilitates flow of coolant directly between that coolant-carrying tube section of the heat exchanger and the coolant-cooled structure.

  11. 火力发电厂采暖空调系统余热利用优化设计%The Optimum Design of the Waste Heat Utilization of Heating&Air-conditioning System in Thermal Power Plant

    费洪磊; 刘欢; 薛岑


    我国能源紧缺,一次能源及各种余热资源利用水平较低,深度挖掘利用电厂余热,制定合理的回收利用方案,优化设计采暖空调系统,提高电厂余热利用率十分重要. 基于电厂采暖空调系统余热利用存在的问题,详细介绍了火力发电厂采暖空调系统余热利用的优化设计.%Because of the energy shortage and a lower utilization level of primary energy and various waste heat resources utilization in China, the deep excavation and utilization of the waste heat in thermal power plant, the formulation of reasonable recycling scheme, the optimum design of heating & air-conditioning system and the improvement of utilization rate of waste heat are very important.Based on the problems existing in the waste heat utilization of heating&air-conditioning system in thermal power plant, this paper introduces in detail the optimum design of the waste heat utilization of heating&air-conditioning system in thermal power plant.

  12. Energy reduction in buildings in temperate and tropic regions utilizing a heat loss measuring device

    Sørensen, Lars Schiøtt


    to ACMV in the "warm countries" contribute to an enormous energy consumption and corresponding CO2 emission. In order to establish the best basis for energy renovation, it is important to have measures of the heat losses on a building façade, for optimizing the energy renovation. This paper will present...... penetration through facades with the aim to reduce the costs to AC. The paper will introduce a common project between NUS (National University of Singapore), AAU (Aalborg University) and HT-Meter, the latter as the U-value Meter developer company. In the project we will measure the heat transfer in the unit W...... of the project. Furthermore this paper present results from already conducted heat loss measurements in the temperate regions....

  13. The earth-coupled heat pump: Utilizing innovative technology in single family rehabilitation strategies


    The study examines the feasibility of incorporating the use of earth-coupled heat pump technology in single-family housing rehabilitation projects, based on energy conservation attributes and financial considerations. Following evaluation of a theoretical model which indicated that installations of the heat pumps were feasible, the heat pumps were tested under actual conditions in five single family housing units which were part of the Urban Homesteading Program, and were matched with comparable units which did not receive special treatment. Energy consumption information was collected for all units for twelve months. Variables were identified, and the data was analyzed for individual housing units and compared with the results predicted by the theoretical model to determine the practicality of incorporating such technology in large scale rehabilitation projects. 14 refs., 14 figs., 3 tabs.

  14. Energy and Exergy Analysis of Kalina Cycle for the Utilization of Waste Heat in Brine Water for Indonesian Geothermal Field

    Nasruddin Nasruddin


    Full Text Available The utilization of waste heat in a power plant system—which would otherwise be released back to the environment—in order to produce additional power increases the efficiency of the system itself. The purpose of this study is to present an energy and exergy analysis of Kalina Cycle System (KCS 11, which is proposed to be utilized to generate additional electric power from the waste heat contained in geothermal brine water available in the Lahendong Geothermal power plant site in North Sulawesi, Indonesia. A modeling application on energy and exergy system is used to study the design of thermal system which uses KCS 11. To obtain the maximum power output and maximum efficiency, the system is optimized based on the mass fraction of working fluid (ammonia-water, as well as based on the turbine exhaust pressure. The result of the simulation is the optimum theoretical performance of KCS 11, which has the highest possible power output and efficiency. The energy flow diagram and exergy diagram (Grassman diagram was also presented for KCS 11 optimum system to give quantitative information regarding energy flow from the heat source to system components and the proportion of the exergy input dissipated in the various system components.

  15. Experimental investigations on prototype heat storage units utilizing stable supercooling of sodium acetate trihydrate mixtures

    Dannemand, Mark; Dragsted, Janne; Fan, Jianhua;


    was filled with 220 kg SAT mixture thickened with 1% carboxymethyl cellulose. The heat exchange capacity rate during the charging of the unit with the extra water was significantly higher than for the unit with the thickening agent due to the different levels of convection. The SAT mixtures in the units were......Laboratory tests of two heat storage units based on the principle of stable supercooling of sodium acetate trihydrate (SAT) mixtures were carried out. One unit was filled with 199.5 kg of SAT with 9% extra water to avoid phase separation of the incongruently melting salt hydrate. The other unit...

  16. Core conditions for alpha heating attained in direct-drive inertial confinement fusion

    Bose, A.; Woo, K. M.; Betti, R.; Campbell, E. M.; Mangino, D.; Christopherson, A. R.; McCrory, R. L.; Nora, R.; Regan, S. P.; Goncharov, V. N.; Sangster, T. C.; Forrest, C. J.; Frenje, J.; Gatu Johnson, M.; Glebov, V. Yu; Knauer, J. P.; Marshall, F. J.; Stoeckl, C.; Theobald, W.


    It is shown that direct-drive implosions on the OMEGA laser have achieved core conditions that would lead to significant alpha heating at incident energies available on the National Ignition Facility (NIF) scale. The extrapolation of the experimental results from OMEGA to NIF energy assumes only that the implosion hydrodynamic efficiency is unchanged at higher energies. This approach is independent of the uncertainties in the physical mechanism that degrade implosions on OMEGA, and relies solely on a volumetric scaling of the experimentally observed core conditions. It is estimated that the current best-performing OMEGA implosion [Regan et al., Phys. Rev. Lett. 117, 025001 (2016), 10.1103/PhysRevLett.117.025001] extrapolated to a 1.9 MJ laser driver with the same illumination configuration and laser-target coupling would produce 125 kJ of fusion energy with similar levels of alpha heating observed in current highest performing indirect-drive NIF implosions.

  17. Core conditions for alpha heating attained in direct-drive inertial confinement fusion.

    Bose, A; Woo, K M; Betti, R; Campbell, E M; Mangino, D; Christopherson, A R; McCrory, R L; Nora, R; Regan, S P; Goncharov, V N; Sangster, T C; Forrest, C J; Frenje, J; Gatu Johnson, M; Glebov, V Yu; Knauer, J P; Marshall, F J; Stoeckl, C; Theobald, W


    It is shown that direct-drive implosions on the OMEGA laser have achieved core conditions that would lead to significant alpha heating at incident energies available on the National Ignition Facility (NIF) scale. The extrapolation of the experimental results from OMEGA to NIF energy assumes only that the implosion hydrodynamic efficiency is unchanged at higher energies. This approach is independent of the uncertainties in the physical mechanism that degrade implosions on OMEGA, and relies solely on a volumetric scaling of the experimentally observed core conditions. It is estimated that the current best-performing OMEGA implosion [Regan et al., Phys. Rev. Lett. 117, 025001 (2016)10.1103/PhysRevLett.117.025001] extrapolated to a 1.9 MJ laser driver with the same illumination configuration and laser-target coupling would produce 125 kJ of fusion energy with similar levels of alpha heating observed in current highest performing indirect-drive NIF implosions.

  18. Simulation of Solar Heat Pump Dryer Directly Driven by Photovoltaic Panels

    Houhou, H.; Yuan, W.; Wang, G.


    This paper investigates a new type of solar heat pump dryer directly driven by photovoltaic panels. In order to design this system, a mathematical model has been established describing the whole drying process, including models of key components and phenomena of heat and mass transfer at the product layer and the air. The results of simulation at different drying air temperatures and velocities have been calculated and it indicate that the temperature of drying air is crucial external parameter compared to the velocity, with the increase of drying temperature from 45°C to 55°C, the product moisture content (Kg water/Kg dry product) decreased from 0.75 Kg/Kg to 0.3 Kg/Kg.

  19. Results of direct measurements of the plasma potential using a laser-heated emissive probe

    Schrittwieser, R.; Sarma, A.; Amarandei, G.; Ionita, C. [Univ. of Innsbruck (Austria). Inst. for Ion Physics; Klinger, T.; Grulke, O.; Vogelsang, A.; Windisch, T. [Max Planck Inst. for Plasma Physics, Greifswald (Germany)


    Reliable diagnostics of the plasma potential is one of the most important challenges in context with the production, control and confinement of a plasma. Emissive probes are readily available as direct diagnostic tools for the plasma potential with a good temporal and spatial resolution in many plasmas, even up to middle-sized fusion experiments. We present the results of investigations on the heating of lanthanum hexaboride and graphite with an infrared diode laser and on the development of a laser-heated emissive probe. Such a probe has a higher electron emission, much longer life time and better time response than a conventional emissive wire probe. We have observed that from both materials electron emission current can be achieved sufficiently strongly even for dense laboratory and experimental fusion plasmas.

  20. Utilizing Direct Numerical Simulations of Transition and Turbulence in Design Optimization

    Rai, Man M.


    Design optimization methods that use the Reynolds-averaged Navier-Stokes equations with the associated turbulence and transition models, or other model-based forms of the governing equations, may result in aerodynamic designs with actual performance levels that are noticeably different from the expected values because of the complexity of modeling turbulence/transition accurately in certain flows. Flow phenomena such as wake-blade interaction and trailing edge vortex shedding in turbines and compressors (examples of such flows) may require a computational approach that is free of transition/turbulence models, such as direct numerical simulations (DNS), for the underlying physics to be computed accurately. Here we explore the possibility of utilizing DNS data in designing a turbine blade section. The ultimate objective is to substantially reduce differences between predicted performance metrics and those obtained in reality. The redesign of a typical low-pressure turbine blade section with the goal of reducing total pressure loss in the row is provided as an example. The basic ideas presented here are of course just as applicable elsewhere in aerodynamic shape optimization as long as the computational costs are not excessive.

  1. Direct Data Domain Sparsity-Based STAP Utilizing Subaperture Smoothing Techniques

    Zhaocheng Yang


    Full Text Available We propose a novel direct data domain (D3 sparsity-based space-time adaptive processing (STAP algorithm utilizing subaperture smoothing techniques for airborne radar applications. Different from either normal sparsity-based STAP or D3 sparsity-based STAP, the proposed algorithm firstly uses only the snapshot in the cell under test (CUT to generate multiple subsnapshots by exploiting the space-time structure of the steering vector and the uncorrelated nature of the components of the interference covariance matrix. Since the interference spectrum is sparse in the whole angle-Doppler plane, by employing a sparse regularization, the generated multiple subsnapshots are jointly used to recover the interference spectrum. The interference covariance matrix is then estimated from the interference spectrum, followed by the space-time filtering and the target detection. Simulation results illustrate that the proposed algorithm outperforms the generalized forward/backward method, the conventional D3 least squares STAP algorithm, and the existing D3 sparsity-based STAP algorithm. Furthermore, compared with the normal sparsity-based STAP algorithm using multiple snapshots, the proposed algorithm can also avoid the performance degradation caused by discrete interferers merely appearing in the CUT.

  2. Performance Analysis of Organic Rankine-vapor Compression Ice Maker Utilizing Food Industry Waste Heat

    Bing Hu


    Full Text Available To develop the organic Rankine-vapor compression ice maker driven by food industry exhaust gases and engine cooling water, an organic Rankine-vapor compression cycle system was employed for ice making and a thermodynamic model was developed and the effects of working fluid types, hot water temperature and condensation temperature on the system performance were analyzed and the ice making capacity from unit mass hot water and unit power waste heat were evaluated. The calculated results show that the working fluid type and the temperatures of heat source and condensation have important effects on the system performance. The system can achieve optimal performance when use R245fa as power and refrigeration medium. The ice quantity generated from per ton hot water is 86.42 kg and the ice-making rate for per kW waste heat is 2.27 kg/h, when the temperatures of hot water and condensation are respectively 100 and 40°C. A conclusion can be draw by the calculation and analysis that using organic Rankine-vapor compression system for ice making from food industry waste heat is feasible.

  3. Cost-utility analysis of direct VAD versus double bridges to heart transplantation in patients with refractory heart failure.

    Chang, Hsiao-Huang; Chen, Po-Lin; Chen, I-Ming; Kuo, Tzu-Ting; Weng, Zen-Chung; Huang, Pei-Jung; Wu, Nai-Yuan; Cheng, Ching-Li


    This study compared the cost-utility of direct ventricular assist device (VAD) versus double bridges, extracorporeal membrane oxygenation (ECMO) before VAD, to heart transplantation in patients with refractory heart failure. From a health payer perspective, a Markov model was developed. The cycle length was one month and the time horizon was a lifetime. Probabilities and direct cost data were calculated from a nationwide claim database. Utility inputs were adopted from published sources. The utility was expressed as quality adjusted life years (QALYs). Both costs and utility were discounted by an annual rate of 3%. Deterministic and probabilistic sensitivity analyses were performed to test the stability of the model. The direct VAD group had less life time costs (USD 95,910] v. USD 129,516) but higher life time QALYs than the double bridges group (1.73 vs. 0.89). The sensitivity analysis revealed that the direct VAD group consistently had lower cost and higher QALYs during all variations in model parameters. The probability that direct VAD was cost-effective exceeded 75% at any levels of willing-to-pay. From a health-insurance payer perspective, direct VAD bridge to heart transplantation appeared to be more cost-effective than double bridges in patients with refractory heart failure. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. Evaluation of a direct contact heat exchanger; Evaluacion de un intercambiador de calor de contacto directo

    Siqueiros, J.; Bonilla, O. [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)


    In this paper the application areas of the direct contact heat exchangers is discussed, as well as its main characteristics. A description is made of the experimental equipment designed and built at pilot scale including the instrumentation employed. The methodology employed as well as the analysis and the discussion of the results are also presented. [Espanol] Se mencionan las areas de aplicacion de los intercambiadores de calor de contacto directo, asi como sus caracteristicas principales. Se describe el equipo experimental a nivel piloto disenado y construido incluyendo la instrumentacion utilizada. Se presenta la metodologia empleada asi como el analisis y discusion de los resultados.

  5. Contact printing for direct metallic pattern transfer based on pulsed infrared laser heating

    Chen, Chun-Hung; Lee, Yung-Chun


    This paper reports a novel contact printing method which can transfer patterned metallic films directly from a mold to a substrate, based on applied contact pressure and infrared pulse laser heating. Experiments have been carried out using a 1064 nm pulsed Nd:YAG laser to demonstrate the feasibility of the proposed method. Chromium (Cr) films of 70 nm thickness with both array-dot patterns and linear grating patterns of typically 500 nm feature sizes are successfully transferred. The transferred Cr patterns can serve as an etching mask for the subsequent etching on the substrate. The potential for applying this method to nano-patterning and nano-fabrication is addressed.

  6. Power plant waste heat utilization in aquaculture. Semi-annual report No. 1, 1 November 1976-1 April 1977

    Guerra, C.R.; Godfriaux, B.L.; Eble, A.F.


    A pilot aquaculture facility utilizing heated river water from condenser cooling (Mercer Generating Station, Trenton, New Jersey) is being used to culture the freshwater shrimp (Macrobrachium rosenbergii) and American eel (Anguilla rostrata) during the warmer months of the year and rainbow trout (Salmo gairdneri) during the colder months. Laboratory tests are also being conducted at Rutgers University to develop shrimp feeds with supplemented amino acids in order to reduce feed costs. Most of the work during the first six months of the proof-of-concept phase of the Mercer Aquaculture Project has been concerned with facility design, groundwater well construction and trials of the groundwater on trout.

  7. Performance Analysis of Organic Rankine-vapor Compression Ice Maker Utilizing Food Industry Waste Heat

    Bing Hu; Yuanshu Cao; Weibin Ma


    To develop the organic Rankine-vapor compression ice maker driven by food industry exhaust gases and engine cooling water, an organic Rankine-vapor compression cycle system was employed for ice making and a thermodynamic model was developed and the effects of working fluid types, hot water temperature and condensation temperature on the system performance were analyzed and the ice making capacity from unit mass hot water and unit power waste heat were evaluated. The calculated results show th...

  8. Geothermal waste heat utilization from in situ thermal bitumen recovery operations.

    Nakevska, Nevenka; Schincariol, Robert A; Dehkordi, S Emad; Cheadle, Burns A


    In situ thermal methods for bitumen extraction introduce a tremendous amount of energy into the reservoirs raising ambient temperatures of 13 °C to as high as 200 °C at the steam chamber edge and 50 °C along the reservoir edge. In essence these operations have unintentionally acted as underground thermal energy storage systems which can be recovered after completion of bitumen extraction activities. Groundwater flow and heat transport models of the Cold Lake, Alberta, reservoir, coupled with a borehole heat exchanger (BHE) model, allowed for investigating the use of closed-loop geothermal systems for energy recovery. Three types of BHEs (single U-tube, double U-tube, coaxial) were tested and analyzed by comparing outlet temperatures and corresponding heat extraction rates. Initial one year continuous operation simulations show that the double U-tube configuration had the best performance producing an average temperature difference of 5.7 °C, and an average heat extraction of 41 W/m. Given the top of the reservoir is at a depth of 400 m, polyethylene piping provided for larger extraction gains over more thermally conductive steel piping. Thirty year operation simulations illustrate that allowing 6 month cyclic recovery periods only increases the loop temperature gain by a factor of 1.2 over continuous operation. Due to the wide spacing of existing boreholes and reservoir depth, only a small fraction of the energy is efficiently recovered. Drilling additional boreholes between existing wells would increase energy extraction. In areas with shallower bitumen deposits such as the Athabasca region, i.e. 65 to 115 m deep, BHE efficiencies should be larger.


    H.-T. Chang


    Full Text Available Urban Heat Island (UHI has been becoming a key factor in deteriorating the urban ecological environment. Spatial-temporal analysis on its prototype of basin city’s UHI and quantitatively evaluating effect from rapid urbanization will provide theoretical foundation for relieving UHI effect. Based on Landsat 8, ETM+ and TM images of Taipei basin areas from 1900 to 2015, this article has retrieved the land surface temperature (LST at summer solstice of each year, and then analysed spatial-temporal pattern and evolution characters of UHI in Taipei basin in this decade. The results showed that the expansion built district, UHI area constantly expanded from centre city to the suburb areas. The prototype of UHI in Taipei basin that showed in addition to higher temperatures in the centre city also were relatively high temperatures gathered boundaries surrounded by foot of mountains side. It calls “sinking heat island”. From 1900 to 2000, the higher UHI areas were different land use type change had obvious difference by public infrastructure works. And then, in next 15 years till 2015, building density of urban area has been increasing gradually. It has the trend that UHI flooding raises follow urban land use density. Hot spot of UHI in Taipei basin also has the same characteristics. The results suggest that anthropogenic heat release probably plays a significant role in the UHI effect, and must be considered in urban planning adaptation strategies.

  10. Eutectic Bonding Utilizing Radio Frequency Induction Heating for Fabricating Vertical Light-Emitting Diodes.

    Choi, Eunmi; Kim, Areum; Cui, Yinhua; Chae, Su Jin; Nam, Minwoo; Kwon, Soon Hyeong; Cha, Yong Won; Pyo, Sung Gyu


    Vertical light-emitting diodes (VLEDs) have attracted considerable attention owing to their improved thermal, electrical, and optical performance compared to conventional LEDs. To fabricate VLEDs, a bonding technique is required following laser lift-off. Eutectic bonding techniques are preferred owing to their low-heat mechanism and production safety. However, the conventional resistance heating method for eutectic bonding process, the extremely longer process time becomes a problem such as cost rise, wapage. In this study, the thermal efficiency was measured according to the diameter of the coil in order to optimize the eutectic bonding of the RF induction heating method in order to solve this problem. We confirmed that successful eutectic bonding is possible with less than 30 min processing using Sn-Glass. In addition, Au (20 wt%)/Sn (80 wt%) alloy, a mainly used the eutectic bonding interlayer material for VLEDs, can also be used as an interlayer to provide void-free eutectic bonding in less than 30 min.

  11. a Temporal and Spatial Analysis of Urban Heat Island in Basin City Utilizing Remote Sensing Techniques

    Chang, Hsiao-Tung


    Urban Heat Island (UHI) has been becoming a key factor in deteriorating the urban ecological environment. Spatial-temporal analysis on its prototype of basin city's UHI and quantitatively evaluating effect from rapid urbanization will provide theoretical foundation for relieving UHI effect. Based on Landsat 8, ETM+ and TM images of Taipei basin areas from 1900 to 2015, this article has retrieved the land surface temperature (LST) at summer solstice of each year, and then analysed spatial-temporal pattern and evolution characters of UHI in Taipei basin in this decade. The results showed that the expansion built district, UHI area constantly expanded from centre city to the suburb areas. The prototype of UHI in Taipei basin that showed in addition to higher temperatures in the centre city also were relatively high temperatures gathered boundaries surrounded by foot of mountains side. It calls "sinking heat island". From 1900 to 2000, the higher UHI areas were different land use type change had obvious difference by public infrastructure works. And then, in next 15 years till 2015, building density of urban area has been increasing gradually. It has the trend that UHI flooding raises follow urban land use density. Hot spot of UHI in Taipei basin also has the same characteristics. The results suggest that anthropogenic heat release probably plays a significant role in the UHI effect, and must be considered in urban planning adaptation strategies.

  12. Research of energy efficiency direct-heating systems with sequential connection of space heaters with different methods of heat consumption regulation

    Morozov Maxim N.


    Full Text Available A model of the building heating system, consisting of energy source, a distributed automatic control system, elements of individual heating unit and heating system is designed. Application Simulink of mathematical package Matlab is selected as a platform for the model. There are the specialized application Simscape libraries in aggregate with a wide range of Matlab mathematical tools allow to apply the “acausal” modeling concept. The conducted research of single-pipe heating system configuration and automatic control system allowed comparing the integral parameters of the systems with local and individual regulation. The results of research of thermal condition premises, situated in the extreme movement direction of the coolant are given. The conclusions about the possibility of increasing the operational efficiency of single-pipe heating system configuration in the implementation of distributed control systems are presented.

  13. A Chebyshev Collocation Method for Moving Boundaries, Heat Transfer, and Convection During Directional Solidification

    Zhang, Yiqiang; Alexander, J. I. D.; Ouazzani, J.


    Free and moving boundary problems require the simultaneous solution of unknown field variables and the boundaries of the domains on which these variables are defined. There are many technologically important processes that lead to moving boundary problems associated with fluid surfaces and solid-fluid boundaries. These include crystal growth, metal alloy and glass solidification, melting and name propagation. The directional solidification of semi-conductor crystals by the Bridgman-Stockbarger method is a typical example of such a complex process. A numerical model of this growth method must solve the appropriate heat, mass and momentum transfer equations and determine the location of the melt-solid interface. In this work, a Chebyshev pseudospectra collocation method is adapted to the problem of directional solidification. Implementation involves a solution algorithm that combines domain decomposition, finite-difference preconditioned conjugate minimum residual method and a Picard type iterative scheme.

  14. Flow through reactors for organic chemistry: directly electrically heated tubular mini reactors as an enabling technology for organic synthesis

    Ulrich Kunz


    Full Text Available Until recently traditional heating in organic chemistry has been done with oil heating baths or using electric heat exchangers. With the advent of microwave equipment, heating by microwaves was rapidly introduced as standard method in organic chemistry laboratories, mainly because of the convenient possibility to operate at high temperature accompanied by accelerated reaction rates. In the present contribution we discuss the method of heating small, continuously operated reactors by passing electric current directly through the reactor wall as an enabling technology in organic chemistry. The benefit of this method is that the heat is generated directly inside the reactor wall. By this means high heating rates comparable to microwave ovens can be reached but at much lower cost for the equipment. A tool for the comparison of microwave heating and traditional heating is provided. As an example kinetic data for the acid catalyzed hydrolysis of methyl formate were measured using this heating concept. The reaction is not only a suitable model but also one of industrial importance since this is the main production process for formic acid.

  15. Flow through reactors for organic chemistry: directly electrically heated tubular mini reactors as an enabling technology for organic synthesis.

    Kunz, Ulrich; Turek, Thomas


    Until recently traditional heating in organic chemistry has been done with oil heating baths or using electric heat exchangers. With the advent of microwave equipment, heating by microwaves was rapidly introduced as standard method in organic chemistry laboratories, mainly because of the convenient possibility to operate at high temperature accompanied by accelerated reaction rates. In the present contribution we discuss the method of heating small, continuously operated reactors by passing electric current directly through the reactor wall as an enabling technology in organic chemistry. The benefit of this method is that the heat is generated directly inside the reactor wall. By this means high heating rates comparable to microwave ovens can be reached but at much lower cost for the equipment. A tool for the comparison of microwave heating and traditional heating is provided. As an example kinetic data for the acid catalyzed hydrolysis of methyl formate were measured using this heating concept. The reaction is not only a suitable model but also one of industrial importance since this is the main production process for formic acid.

  16. Flow through reactors for organic chemistry: directly electrically heated tubular mini reactors as an enabling technology for organic synthesis

    Turek, Thomas


    Summary Until recently traditional heating in organic chemistry has been done with oil heating baths or using electric heat exchangers. With the advent of microwave equipment, heating by microwaves was rapidly introduced as standard method in organic chemistry laboratories, mainly because of the convenient possibility to operate at high temperature accompanied by accelerated reaction rates. In the present contribution we discuss the method of heating small, continuously operated reactors by passing electric current directly through the reactor wall as an enabling technology in organic chemistry. The benefit of this method is that the heat is generated directly inside the reactor wall. By this means high heating rates comparable to microwave ovens can be reached but at much lower cost for the equipment. A tool for the comparison of microwave heating and traditional heating is provided. As an example kinetic data for the acid catalyzed hydrolysis of methyl formate were measured using this heating concept. The reaction is not only a suitable model but also one of industrial importance since this is the main production process for formic acid. PMID:20300506

  17. The direct application of geothermal energy to provide process heat in Guatemala

    Altseimer, J.H.; Edeskuty, F.J.


    One part of an energy and resource development program in Central America is a geothermal process heat project in Guatemala. The feasibility of the direct heat application depends upon the production characteristics and reliability of the geothermal source. Other factors are the distance from the heat source, quantity of use, and capacity factor of the use facilities. Favorable conditions would be distances of under 5 km, heat requirements approximately equal to the well capacity, and high capacity factors (say 60% or higher) in the industrial plants. Depending upon the values of these factors, energy costs of less than $1.00/million Btus to greater than $5.00/million Btus have been estimated. This can be compared to about $5.00/million Btus for petroleum-based fuels in Guatemala in mid 1987. A survey was made of existing industries in the Amatitlan and Zunil geothermal areas. In both Amatitlan and Zunil the existing industries are spread out over an area too large to be called an optimum. The most promising situation for an industrial park development is at Amatitlan, except that proven production wells are not yet available. At Zunil, production wells exist, but a diverse nearby industrial base does not. However, both of these two areas are sufficiently promising to merit further development. Consequently, a demonstration project is underway aimed at the ultimate establishment of an agricultural processing center at Zunil. This center would have the capability to process agricultural products by dehydration, freezing, and cold storage. 2 refs., 4 figs., 2 tabs.

  18. 宝钢低温余热利用现状及前景分析%Analysis of the low-temperature heat utilization of the present and prospects in Baosteel

    张颖; 桂其林; 王晓明


    宝钢一直重视余热(能)回收利用工作,近几年宝钢在低温余热回收方面也取得了重要的进步。分析了宝钢股份总部低温余热资源及低温余热利用现状,重点介绍了宝钢在加热炉、退火炉以及低压锅炉烟气余热回收等几种典型的低温余热回收利用技术,根据目前余热回收利用工作的推进进度,分析了宝钢低温余热回收下一步的工作方向和余热利用前景。%Baosteel has long been valuing the recycling and reuse of waste heat ( energy) , meantime has achieved great progress on the utilization of low-temperature waste heat over the recent years.The resources and the status of the low-temperature waste heat utilization in the area of Baosteel headquar-ters were described.Several typical low-temperature recycling techniques were introduced such as flue gas waste heat recycling which were applied to heating furnace, annealing furnace, and low-pres-sure boiler.Based on the current working schedule of waste heat recycling, the next phase working di-rection of low-temperature waste heat recycle and prospects of waste heat utilization in Baosteel were analyzed.

  19. Achievement of Core Conditions for Alpha Heating in Direct-Drive Inertial Confinement Fusion

    Bose, A.; Woo, K. M.; Betti, R.; Mangino, D.; Christopherson, A. R.; Theobald, W.; Campbell, E. M.; McCrory, R. L.; Regan, S. P.; Goncharov, V. N.; Sangster, T. C.; Forrest, C. J.; Glebov, V. Yu.; Knauer, J. P.; Marshall, F. J.; Stoeckl, C.; Nora, R.; Frenje, J. A.; Gatu Johnson, M.; Shvarts, D.


    It is shown for the first time that direct-drive implosions on the OMEGA laser have achieved core conditions that would lead to significant alpha heating at incident energies available at the National Ignition Facility (NIF) scale. The extrapolation of the experimental results from OMEGA to NIF energy assumes only that the implosion hydrodynamic efficiency is unchanged at higher energies. This approach is independent of the uncertainties in the physical mechanism that degrade implosions on OMEGA, and relies solely on a volumetric scaling of the experimentally observed core conditions. It is estimated that the current best-performing OMEGA implosion extrapolated to a 1.9-MJ laser driver with the same illumination configuration and laser-target coupling would produce 125 kJ of fusion energy with similar levels of alpha heating observed in current highest performing indirect-drive NIF implosions. This conclusion is reached using an analytic scaling as well as direct numerical simulations of energy-scaled targets. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number DE-NA0001944.



    Direct Nmerical Simulation (DNS) of turbulent heat transfer in a wall-normal rotating channel flow has been carried out for the rotation number Nτ from 0 to 0.1, the Reynolds number 194 based on the friction velocity of non-rotating case and the half-height of the channel, and the Prandtl number 1. The objective of this study is to reveal the effects of rotation on the characteristics of turbulent flow and heat transfer. Based on the present calculated results, two typical rotation regimes are identified. When 0<Nτ<0.06, turbulence and thermal statistics correlated with the spanwise velocity fluctuation are enhanced since the shear rate of spanwise mean flow induced by Coriolis force increases; however, the other statistics are suppressed. When Nτ>0.06, turbulence and thermal statistics are suppressed significantly because the Coriolis force effect plays as a dominated role in the rotating flow. Remarkable change of the direction of near-wall streak structures based on the velocity and temperature fluctuations is identified.

  1. Geothermal direct heat use: Market potential/penetration analysis for Federal Region 9

    Powell, W. (Editor); Tang, K. (Editor)


    A preliminary study was made of the potential for geothermal direct heat use in Arizona, California, Hawaii, and Nevada (Federal Region 9). An analysis was made of each state to: (1) define the resource, based on the latest available data; (2) assess the potential market growth for geothermal energy; and (3) estimate the market penetration, projected to 2020. Findings of the study include the following: (1) Potentially economical hydrothermal resources exist in all four states of the Region: however, the resource data base is largely incomplete, particularly for low to moderate temperature resources. (2) In terms of beneficial heat, the total hydrothermal resource identified so far for the four states is on the order of 43 Quads, including an estimated 34 Quads of high temperature resources which are suitable for direct as well as electrical applications. (3) In California, Hawaii, and Nevada, the industrial market sector has somewhat greater potential for penetration than the residential/commercial sector. In Arizona, however, the situation is reversed, due to the collocation of two major metropolitan areas (Phoenix and Tucson) with potential geothermal resources.

  2. Manual for the thermal and hdyraulic design of direct contract spray columns for use in extracting heat from geothermal brines

    Jacobs, H. R.


    This report outlines the current methods being used in the thermal and hydraulic design of spray column type, direct contact heat exchangers. It provides appropriate referenced equations for both preliminary design and detailed performance. The design methods are primarily empirical and are applicable for use in the design of such units for geothermal application and for application with solar ponds. Methods for design, for both preheater and boiler sections of the primary heat exchangers, for direct contact binary powers plants are included.


    I E. Lobanov


    Full Text Available Objectives. The aim of present work was to carry out mathematical modelling of heat transfer with symmetrical heating in flat channels and round pipes with rough walls.Methods. The calculation was carried out using the L'Hôpital-Bernoulli's method. The solution of the problem of intensified heat transfer in a round tube with rough walls was obtained using the Lyon's integral.Results. Different from existing theories, a methodology of theoretical computational heat transfer determination for flat rough channels and round pipes with rough walls is developed on the basis of the principle of full viscosity superposition in a turbulent boundary layer. The analysis of the calculated heat transfer and hydroresistivity values for flat rough channels and round rough pipes shows that the increase in heat transfer is always less than the corresponding increase in hydraulic resistance, which is a disadvantage as compared to channels with turbulators, with all else being equal. The results of calculating the heat transfer for channels with rough walls in an extended range of determinant parameters, which differ significantly from the corresponding data for the channels with turbulators, determine the level of heat exchange intensification.Conclusion. An increase in the calculated values of the relative average heat transfer Nu/NuGL for flat rough channels and rough pipes with very high values of the relative roughness is significantly contributed by both an increase in the relative roughness height and an increase in the Reynolds number Re. In comparison with empirical dependencies, the main advantage of solutions for averaged heat transfer in rough flat channels and round pipes under symmetrical thermal load obtained according to the developed theory is that they allow the calculation of heat exchange in rough pipes to be made in the case of large and very large relative heights of roughness protrusions, including large Reynolds numbers, typical for pipes

  4. Advanced vapor compression heat pump cycle utilizing non-azeotropic working fluid mixtures

    Radermacher, R.


    A method of transferring heat from a first fluid having a temperature T/sub 1/ to a second fluid having a temperature T/sub 2/, when the temperature T/sub 2/ is greater than the temperature T/sub 1/ is described comprising: providing a third fluid, comprising a mixture of a higher boiling component and a lower boiling component, having a temperature T/sub A/, T/sub A/ being less than T/sub 1/; adding heat to the third fluid to raise the temperature of the third fluid to a temperature T/sub B/, T/sub B/ being greater than T/sub A/ and less than or substantially equal to T/sub 1/; separating the first liquid from the first vapor; compressing the first vapor to form a secondary pressurized vapor stream; pumping the first liquid into contact with the secondary pressurized vapor stream to form a pressurized fourth fluid having a temperature T/sub C/, T/sub C/ being greater than T/sub 2/; removing heat from the fourth fluid to lower the temperature of the fourth fluid to a temperature T/sub D/, T/sub D/ being less than T/sub C/ and greater than or substantially equal to T/sub 2/, whereby the secondary pressurized vapor stream is absorbed to form in admixture with the first liquid, a pressurized second liquid, the temperature T/sub D/ being greater than T/sub A/ and less than T/sub B/, the temperature T/sub B/ being greater than T/sub D/ and less than T/sub C/; expanding the pressurized second liquid to form the third fluid.

  5. Novel regulation of yolk utilization by thyroid hormone in embryos of the direct developing frog Eleutherodactylus coqui.

    Singamsetty, Srikanth; Elinson, Richard P


    Thyroid hormone (TH) is required for metamorphosis of the long, coiled tadpole gut into the short frog gut. Eleutherodactylus coqui, a direct developing frog, lacks a tadpole. Its embryonic gut is a miniature adult form with a mass of yolky cells, called nutritional endoderm, attached to the small intestine. We tested the TH requirement for gut development in E. coqui. Inhibition of TH synthesis with methimazole arrested gut development in its embryonic form. Embryos treated with methimazole failed to utilize the yolk in their nutritional endoderm, and survived for weeks without further development. Conversely, methimazole and 3,3',5-tri-iodo-l-thyronine, the active form of TH, stimulated gut development and utilization and disappearance of the nutritional endoderm. In Xenopus laevis, the receptor for TH, TRβ, is upregulated in response to TH. Similarly, EcTRβ, the E. coqui ortholog, was upregulated by TH in the gut. EcTRβ expression was high in the nutritional endoderm, suggesting a direct role for TH in yolk utilization by these cells. An initial step in the breakdown of yolk in X. laevis is acidification of the yolk platelet. E. coqui embryos in methimazole failed to acidify their yolk platelets, but acidification was stimulated by TH indicating its role in an early step of yolk utilization. In addition to a conserved TH role in gut development, a novel regulatory role for TH in yolk utilization has evolved in these direct developers.

  6. Discussion on Effective Utilization of Waste Heat from Coal Fired Heat Carrier Furnace%燃煤热载体加热炉余热有效利用的探讨



    本文介绍了燃煤热载体加热炉的余热利用现状,对余热利用的能效进行了分析,指出一些用热单位虽然采用余热设备降低了加热炉排烟温度,但余热设备产生的新能源却没有用途。提出了余热利用的多种方式,希望用热单位采用符合自身特点的余热利用方式,将节能工作落到实处。%This paper introduces the coal-fired heat carrier furnace waste heat utilization, has carried on the analysis on the efifciency of waste heat utilization, points out that some thermal units while reduce the lfue gas temperature of heating furnace with heat recovery equipment, but the heat generated by the equipment without energy use. We put forward a variety of ways of utilization of waste heat, want to use thermal units with their own characteristics of waste heat utilization, to implement energy-saving work.


    Garrison, S.; Tamburello, D.; Hardy, B.; Anton, D.; Gorbounov, M.; Cognale, C.; van Hassel, B.; Mosher, D.


    Two detailed, unit-cell models, a transverse fin design and a longitudinal fin design, of a combined hydride bed and heat exchanger are developed in COMSOL{reg_sign} Multiphysics incorporating and accounting for heat transfer and reaction kinetic limitations. MatLab{reg_sign} scripts for autonomous model generation are developed and incorporated into (1) a grid-based and (2) a systematic optimization routine based on the Nelder-Mead downhill simplex method to determine the geometrical parameters that lead to the optimal structure for each fin design that maximizes the hydrogen stored within the hydride. The optimal designs for both the transverse and longitudinal fin designs point toward closely-spaced, small cooling fluid tubes. Under the hydrogen feed conditions studied (50 bar), a 25 times improvement or better in the hydrogen storage kinetics will be required to simultaneously meet the Department of Energy technical targets for gravimetric capacity and fill time. These models and methodology can be rapidly applied to other hydrogen storage materials, such as other metal hydrides or to cryoadsorbents, in future work.

  8. Evacuated tubular collector utilizing a heat pipe. Progress report, May 1 1975--August 31, 1975

    Ortabasi, U.; Fehlner, F.P.


    Research and development activities performed by the Corning Glass Works solar group during the period from May 1, 1975 to August 31, 1975 are reported. The analytical studies encompassed optical modeling of a modified cusp reflector, fresnel losses from tubular enclosures as a function of orientation, preliminary work on a digital Monte-Carlo Ray Tracing Computer Code and the determination of U/sub L/ losses as a function of vacuum level and temperature of the absorber. Compatible enclosure materials, wicks and working fluids were selected to assemble heat pipes for use as solar collector absorbers. Cusp reflectors with good accuracy were fabricated from various commercial bright aluminum sheet and their optical properties determined. Evacuation techniques were developed and special bake-out procedures were worked out to assemble the evacuated tubular collectors. The work on selective coatings narrowed down the field of potential absorber films to ''black chrome'' which has good stability in vacuum and the necessary ..cap alpha../epsilon value. Six different heat pipes and one flow-through absorber were fabricated and were partially characterized for thermal performance. Indoor and outdoor test facilities were completed and calibrated within proposed NBS standards. They are now available for parametric as well as true-life experiments with solar radiation.

  9. From waste to value - direct utilization of limonene from orange peel in a biocatalytic cascade reaction towards chiral carvolactone

    Oberleitner, N.; Ressmann, A. K.; Bica, K.; Gaertner, P.; Fraaije, M. W.; Bornscheuer, U. T.; Rudroff, F.; Mihovilovic, M. D.


    In this proof of concept study we demonstrate direct utilization of limonene containing waste product orange peel as starting material for a biocatalytic cascade reaction. The product of this cascade is chiral carvolactone, a promising building block for thermoplastic polymers. Four different concep

  10. Direct experimental evidence for a negative heat capacity in the liquid-to-gas like phase transition in hydrogen cluster ions backbending of the caloric curve

    Gobet, F; Carré, M; Farizon, B; Farizon, M; Gaillard, M J; Maerk, T D; Scheier, P


    By (i) selecting specific decay reactions in high energy collisions (60 keV/amu) of hydrogen cluster ions with a helium target (utilizing event-by-event data of a recently developed multi-coincidence experiment) and by (ii) deriving corresponding temperatures for these microcanonical cluster ensembles (analyzing the respective fragment distributions) we are able to construct caloric curves for ii sub 3 sup + (ii sub 2) sub m cluster ions (6 <= m <= 14). All individual curves and the mean of these curves show a backbending in the plateau region thus constituting direct evidence for a negative microcanonical heat capacity in the liquid-to-gas like transition of these finite systems.

  11. COHO - Utilizing Waste Heat and Carbon Dioxide at Power Plants for Water Treatment

    Kaur, Sumanjeet [Porifera Inc., Hayward, CA (United States); Wilson, Aaron [Porifera Inc., Hayward, CA (United States); Wendt, Daniel [Porifera Inc., Hayward, CA (United States); Mendelssohn, Jeffrey [Porifera Inc., Hayward, CA (United States); Bakajin, Olgica [Porifera Inc., Hayward, CA (United States); Desormeaux, Erik [Porifera Inc., Hayward, CA (United States); Klare, Jennifer [Porifera Inc., Hayward, CA (United States)


    The COHO is a breakthrough water purification system that can concentrate challenging feed waters using carbon dioxide and low-grade heat. For this project, we studied feeds in a lab-scale system to simulate COHO’s potential to operate at coal- powered power plants. COHO proved successful at concentrating the highly scaling and challenging wastewaters derived from a power plant’s cooling towers and flue gas desulfurization units. We also found that COHO was successful at scrubbing carbon dioxide from flue gas mixtures. Thermal regeneration of the switchable polarity solvent forward osmosis draw solution ended up requiring higher temperatures than initially anticipated, but we also found that the draw solution could be polished via reverse osmosis. A techno-economic analysis indicates that installation of a COHO at a power plant for wastewater treatment would result in significant savings.

  12. CAVE3: A general transient heat transfer computer code utilizing eigenvectors and eigenvalues

    Palmieri, J. V.; Rathjen, K. A.


    The method of solution is a hybrid analytical numerical technique which utilizes eigenvalues and eigenvectors. The method is inherently stable, permitting large time steps even with the best of conductors with the finest of mesh sizes which can provide a factor of five reduction in machine time compared to conventional explicit finite difference methods when structures with small time constants are analyzed over long time periods. This code will find utility in analyzing hypersonic missile and aircraft structures which fall naturally into this class. The code is a completely general one in that problems involving any geometry, boundary conditions and materials can be analyzed. This is made possible by requiring the user to establish the thermal network conductances between nodes. Dynamic storage allocation is used to minimize core storage requirements. This report is primarily a user's manual for CAVE3 code. Input and output formats are presented and explained. Sample problems are included which illustrate the usage of the code as well as establish the validity and accuracy of the method.

  13. Assessing the effect of wind speed/direction changes on urban heat island intensity of Istanbul.

    Perim Temizoz, Huriye; Unal, Yurdanur S.


    Assessing the effect of wind speed/direction changes on urban heat island intensity of Istanbul. Perim Temizöz, Deniz H. Diren, Cemre Yürük and Yurdanur S. Ünal Istanbul Technical University, Department of Meteorological Engineering, Maslak, Istanbul, Turkey City or metropolitan areas are significantly warmer than the outlying rural areas since the urban fabrics and artificial surfaces which have different radiative, thermal and aerodynamic features alter the surface energy balance, interact with the regional circulation and introduce anthropogenic sensible heat and moisture into the atmosphere. The temperature contrast between urban and rural areas is most prominent during nighttime since heat is absorbed by day and emitted by night. The intensity of the urban heat island (UHI) vary considerably depending on the prevailent meteorological conditions and the characteristics of the region. Even though urban areas cover a small fraction of Earth, their climate has greater impact on the world's population. Over half of the world population lives in the cities and it is expected to rise within the coming decades. Today almost one fifth of the Turkey's population resides in Istanbul with the percentage expected to increase due to the greater job opportunities compared to the other cities. Its population has been increased from 2 millions to 14 millions since 1960s. Eventually, the city has been expanded tremendously within the last half century, shifting the landscape from vegetation to built up areas. The observations of the last fifty years over Istanbul show that the UHI is most pronounced during summer season. The seasonal temperature differences between urban and suburban sites reach up to 3 K and roughly haft degree increase in UHI intensity is observed after 2000. In this study, we explore the possible range of heat load and distribution over Istanbul for different prevailing wind conditions by using the non-hydrostatic MUKLIMO3 model developed by DWD

  14. Direct Heat-Flux Measurement System (MDF) for Solar central Receiver Evaluation

    Ballestrin, J.


    A direct flux measurement system, MDF, has been designed, constructed and mounted on top of the SSPS-CRS tower at the Plataforma Solar de Almeria (PSA) in addition to an indirect flux measurement system based on a CCD camera. It's one of the main future objectives to compare systematically both measurements of the concentrated solar power, increasing in this way the confidence in the estimate of this quantity. Today everything is prepared to perform the direct flux measurement on the aperture of solar receivers: calorimeter array, data acquisition system and software. the geometry of the receiver determines the operation and analysis procedures to obtain the indecent power onto the defined area. The study of previous experiences with direct flux measurement systems ha been useful to define a new simpler and more accurate system. A description of each component of the MDF system is included, focusing on the heat-flux sensors or calorimeters, which enables these measurements to be done in a few seconds without water-cooling. The incident solar power and the spatial flux distribution on the aperture of the volumetric receiver Hitrec II are supplied by the above-mentioned MDF system. The first results obtained during the evaluation of this solar receiver are presented including a sunrise-sunset test. All these measurements have been concentrated in one coefficient that describes the global behavior of the Solar Power Plant. (Author) 18 refs.

  15. Heat transfer and pressure drop in a compact pin-fin heat exchanger with pin orientation at 18 deg to the flow direction

    Olson, D. A.


    The heat transfer and pressure drop characteristics of a novel, compact heat exchanger in helium gas were measured at 3.5 MPa and Reynolds numbers of 450 to 12,000. The pin-fin specimen consisted of pins, 0.51 mm high and spaced 2.03 mm on centers, spanning a channel through which the helium flows; the angle of the row of pins to the flow direction was 18 deg. The specimen was radiatively heated on the top side at heat fluxes up to 74 W/sq cm and insulated on the back side. Correlations were developed for the friction factor and Nusselt number. The Nusselt number compares favorably to those of past studies of staggered pin-fins, when the measured temperatures are extrapolated to the temperature of the wall-fluid interface.

  16. Direct contact liquid-liquid heat exchanger for solar heated and cooled buildings. Final report, January 1, 1979-May 30, 1980

    Karaki, S.; Brothers, P.


    The technical and economic feasibility of using a direct contact liquid-liquid heat exchanger (DCLLHE) storage unit in a solar heating and cooling system is established. Experimental performance data were obtained from the CSU Solar House I using a DCLLHE for both heating and cooling functions. A simulation model for the system was developed. The model was validated using the experimental data and applied in five different climatic regions of the country for a complete year. The life-cycle cost of the system was estimated for each application. The results are compared to a conventional solar system, using a standard shell-and-tube heat exchanger. It is concluded that while thare is a performance advantage with a DCLLHE system over a conventional solar system, the advantage is not sufficiently large to overcome slightly higher capital and operating costs for the DCLLHE system.

  17. Heat of supersaturation-limited amyloid burst directly monitored by isothermal titration calorimetry

    Ikenoue, Tatsuya; Lee, Young-Ho; Kardos, József; Yagi, Hisashi; Ikegami, Takahisa; Naiki, Hironobu; Goto, Yuji


    Amyloid fibrils form in supersaturated solutions via a nucleation and growth mechanism. Although the structural features of amyloid fibrils have become increasingly clearer, knowledge on the thermodynamics of fibrillation is limited. Furthermore, protein aggregation is not a target of calorimetry, one of the most powerful approaches used to study proteins. Here, with β2-microglobulin, a protein responsible for dialysis-related amyloidosis, we show direct heat measurements of the formation of amyloid fibrils using isothermal titration calorimetry (ITC). The spontaneous fibrillation after a lag phase was accompanied by exothermic heat. The thermodynamic parameters of fibrillation obtained under various protein concentrations and temperatures were consistent with the main-chain dominated structural model of fibrils, in which overall packing was less than that of the native structures. We also characterized the thermodynamics of amorphous aggregation, enabling the comparison of protein folding, amyloid fibrillation, and amorphous aggregation. These results indicate that ITC will become a promising approach for clarifying comprehensively the thermodynamics of protein folding and misfolding. PMID:24753579

  18. Direct numerical simulation of heat transfer in a spatially developing turbulent boundary layer

    Li, Dong; Luo, Kun; Fan, Jianren


    Direct numerical simulation has been performed to investigate heat transfer in a zero-pressure-gradient spatially developing turbulent boundary layer with realistic thermal inflow boundary conditions. The temperature is considered as a passive scalar and the molecular Prandtl number is set to be 0.71. The turbulence statistics for both the velocity and temperature fields show good agreement with previous numerical and experimental data in the literature. The present study provides a valuable database for the spatially developing turbulent thermal boundary layer over a wide range of Reynolds numbers from Reθ = 1100 to 1940. The simulation results indicate that both the peak value and peak location of the streamwise velocity fluctuation grow slightly with increasing Reynolds number, same as those of the temperature fluctuation. The relationship between the streamwise velocity and temperature fluctuations has been examined and a strong correlation is observed in the vicinity of the wall. With increasing distance from the wall, however, the degree of correlation significantly decreases. In addition, the difference between the turbulent velocity and temperature fields is also analysed by investigating the mechanisms of heat and momentum transport in boundary layer flow.

  19. Direct use of geothermal energy, Elko, Nevada district heating. Final report

    Lattin, M.W.; Hoppe, R.D.


    In early 1978 the US Department of Energy, under its Project Opportunity Notice program, granted financial assistance for a project to demonstrate the direct use application of geothermal energy in Elko, Nevada. The project is to provide geothermal energy to three different types of users: a commercial office building, a commercial laundry and a hotel/casino complex, all located in downtown Elko. The project included assessment of the geothermal resource potential, resource exploration drilling, production well drilling, installation of an energy distribution system, spent fluid disposal facility, and connection of the end users buildings. The project was completed in November 1982 and the three end users were brought online in December 1982. Elko Heat Company has been providing continuous service since this time.

  20. Synthesis of Non-molecular Nitrogen Phases at Mbar Pressures by Direct Laser-heating

    Lipp, M J; Klepeis, J P; Baer, B J; Cynn, H; Evans, W J; Iota, V; Yoo, C


    Direct laser heating of molecular N2 to above 1400 K at 120-130 GPa results in the formation of a reddish amorphous phase and a transparent crystalline solid above 2000 K. Raman and x-ray data confirm that the transparent phase is cubic-gauche nitrogen (cg-N), while the reddish color of the amorphous phase might indicate the presence of N=N dish bonds. The quenched amorphous phase is stable down to at least 70GPa, analogous to cg-N, and could be a new non-molecular phase or an extension of the already known {eta}-phase. A chemo-physical phase diagram is presented which emphasizes the difference between pressure- and temperature-induced transitions from molecular to non-molecular solids, as found in other low Z systems.

  1. Simultaneous on-line monitoring of propofol and sevoflurane in balanced anesthesia by direct resistive heating gas chromatography.

    Dong, Hao; Zhang, Feng Jiang; Wang, Fu Yuan; Wang, Ying Ying; Guo, Jing; Kanhar, G M; Chen, Jing; Liu, Jun; Zhou, Chen; Yan, Min; Chen, Xing


    In balanced anesthesia, sevoflurane and propofol are often used in combination to achieve a better anesthetic effect. However, methods for on-line monitoring of concentrations of the two anesthetics in patients are still rare in clinical. This study proposed a non-invasive method utilizing a fast gas chromatograph combined with a surface acoustic wave sensor (Fast GC-SAW) to simultaneously on-line monitor sevoflurane and propofol in patients' exhaled gas. By using the direct resistive heating capillary column, the single detection time of Fast GC-SAW system was significantly shortened to 90s, as well as the size reduced to (40cm×30cm×20cm). Besides, in the calibration of sevoflurane, Fast GC-SAW system showed a good linear correlation (R(2)=0.9925, P<0.01) with gas chromatography-mass spectrometer (GC-MS), which ensured the reliability and accuracy of the Fast GC-SAW system. Finally, clinical experiments on patients under balanced anesthesia were conducted. The varied concentrations measured by Fast GC-SAW extraordinarily matched the clinical usages of these two anesthetics. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Extending life of reversible heat exchangers; Prologando a vida util de trocadores de calor reversiveis

    Fonseca, Ronaldo [White Martins de Ipatinga, MG (Brazil). Usina de Liquidos; Cabral, Antonio Tarciso S. [White Martins de Volta Redonda (Brazil). Usina de Liquidos


    Praxair is one of the three largest industrial gases companies worldwide, with operations in over 40 countries. In Brazil, Praxair is the owner of White Martins, the largest industrial gases company in South America, present in nine countries on the continent and throughout the Brazilian steel industry, operating and supplying products from plants for separation of air gases or other products and services for all steelmaking processes. In addition to technologies of production of atmospheric gases, White Martins includes the production of carbon dioxide, acetylene, hydrogen, specialty and health and care gases, mixtures for welding, gas seamless steel cylinders, storage and gases transportation, equipment for measurement and control of gas injection, following the strictest standards of safety and quality. This paper describe the improvements, availability and reliability gains achieved through implementation of operational control systems of RHX, equipment commonly found in air separation plants, which allowed better monitoring and increasing the useful life of these heat exchangers and to keep the purity of the products supplied for the manufacture of high quality steels. (author)

  3. Studies on Effective Utilization of SOFC Exhaust Heat Using Thermoelectric Power Generation Technology

    Terayama, Takeshi; Nagata, Susumu; Tanaka, Yohei; Momma, Akihiko; Kato, Tohru; Kunii, Masaru; Yamamoto, Atsushi


    Solid oxide fuel cells (SOFCs) are being researched around the world. In Japan, a compact SOFC system with rated alternative current (AC) power of 700 W has become available on the market, since the base load electricity demand for a standard home is said to be less than 700 W AC. To improve the generating efficiency of SOFC systems in the 700-W class, we focused on thermoelectric generation (TEG) technology, since there are a lot of temperature gradients in the system. Analysis based on simulations indicated the possibility of introducing thermoelectric generation at the air preheater, steam generator, and exhaust outlet. Among these options, incorporating a TEG heat exchanger comprising multiple CoSb3/SiGe-based TEG modules into the air preheater had potential to produce additional output of 37.5 W and an improvement in generating efficiency from 46% to 48.5%. Furthermore, by introducing thermoelectric generation at the other two locations, an increase in maximum output of more than 50 W and generating efficiency of 50% can be anticipated.

  4. An Example of Waste Heat Recovery of Heating Furnace Based On Energy Cascade Utilization%基于能量梯级利用的加热炉余热回收实例



    A complex recovery method for heating furnace waste heat based on energy cascade utilization is introduced. Through successful application in a transformation project of walking beam heating furnace, the feasibility and universality of the waste heat recovery method was proved.%介绍了一种基于能量梯级利用的组合式加热炉余热回收方法,通过在一个步进梁式加热炉改造项目中成功应用,证明了此余热回收方法的可行性和通用性.

  5. Putting politics into perspective : A Study of the Implementation of EU public utilities directives

    Berglund, S.K.


    In the area of public utilities, the member states of the European Union (EU) have agreed on ambitious policies to open up markets for competition and to regulate these markets. To have the expected effect, these policies have to be implemented effectively. In this book it is demonstrated that this

  6. Promising Direction of Perfection of the Utilization Combine Cycle Gas Turbine Units

    Gabdullina Albina I.


    Full Text Available Issues of improving the efficiency of combined cycle gas turbines (CCGT recovery type have been presented. Efficiency gas turbine plant reaches values of 45 % due to rise in temperature to a gas turbine to 1700 °C. Modern technologies for improving the cooling gas turbine components and reducing the excess air ratio leads to a further increase of the efficiency by 1-2 %. Based on research conducted at the Tomsk Polytechnic University, it shows that the CCGT efficiency can be increased by 2-3 % in the winter time due to the use of organic Rankine cycle, low-boiling substances, and air-cooled condensers (ACC. It is necessary to apply the waste heat recovery with condensation of water vapor from the flue gas, it will enhance the efficiency of the CCGT by 2-3 % to increase the efficiency of the heat recovery steam boiler (HRSB to 10-12 %. Replacing electric pumps gas turbine engine (GTE helps to reduce electricity consumption for auxiliary needs CCGT by 0.5-1.5 %. At the same time the heat of flue gas turbine engine may be useful used in HRSB, thus will increase the capacity and efficiency of the steam turbine.

  7. Improvement of inhibitor identification for heat shock protein 90α by utilizing a red-shifted fluorescence polarization probe.

    Qian, Jie; Holskin, Beverly P; Theroff, Jay; Underiner, Ted; Meyer, Sheryl L; Angeles, Thelma S


    Heat shock protein-90 (HSP90) is an ATP-dependent molecular chaperone with intrinsic ATPase activity. HSP90 is required for the stability and function of client proteins, many of which are involved in oncogenesis. Thus, identification of HSP90 inhibitors would potentially lead to the discovery of cancer therapeutics. Here, we present a high-throughput screening campaign utilizing two geldanamycin (GM)-labeled probes in a fluorescence polarization (FP) assay. For the primary screen, a previously reported green BODIPY-labeled GM (GM-BODIPY) was used to evaluate a library collection of about 400,000 compounds. From this screen, 3058 compounds showed >30% inhibition. To distinguish true positives from compound interference, a confirmatory screen was deemed necessary. Accordingly, a red-shifted FP binding assay was developed using GM labeled with red BODIPY. This tool enabled reliable identification of promising HSP90α inhibitors.

  8. The concept of entransy and its utilization in the analysis of problems in thermodynamics and heat transfer

    Oliveira, Santiago del Rio [Universidade Tecnologica Federal do Parana (UTFPR), Cornelio Procopio, PR (Brazil)], E-mail:; Milanez, Luiz Fernando [Universidade Estadual de Campinas (UNICAMP), SP (Brazil)], E-mail:


    The concept of entransy was recently proposed in terms of the analogy to the electric energy stored in a capacitor. The entransy of a system describes its heat transfer ability, as the exergy of a system quantifies its work production potential. Hence, the concept of entransy can be useful in problems where the heat transfer is the main objective, as for example, in systems collecting solar energy. This concept is very recent and there are only a few works related to this topic. It is expected, however, that this approach will soon become of extreme importance in the analysis of problems in thermodynamics and heat transfer. The objective of this work is to present a review of the concept of entransy in a systematic way, beginning with its definition, balance equations and a few examples of simple application. It is hoped that this concept of entransy be widely spread in the scientific community and efforts be directed in the sense of improving the thermal sciences. (author)

  9. Effect of thermal heat stress on energy utilization in two lines of pigs divergently selected for residual feed intake.

    Renaudeau, D; Frances, G; Dubois, S; Gilbert, H; Noblet, J


    Castrated males from 2 lines of purebred French Large White obtained from a divergent selection experiment for their residual feed intake (RFI) over 7 generations were measured for their energy utilization during thermal acclimation to increased ambient temperature. The RFI(+) line consumed more feed than predicted from its performance, whereas the RFI- line consumed less feed. Each pig was exposed to 24°C for 7 d (P0) and thereafter to a constant temperature of 32°C for 3 consecutive periods of 7 d (P1, P2, P3). Feed intake, feeding behavior parameters, digestibility, components of heat production (HP; measured by indirect calorimetry in respiration chambers), and energy, nitrogen, fat, and water balance were measured in pigs offered feed and water ad libitum and individually housed in respiratory chambers. Two identical respiratory chambers were simultaneously used, and 5 pigs of each line were measured successively. Whatever the trait, the interaction between line and period was not significant (P > 0.10). On average, ADFI was greater in the RFI+ than in the RFI- line (1,945 vs. 1,639 g/d; P = 0.051) in relation to an increase of the mean size of each feeding bout (128 vs. 82 g/visit; P intake and HP declined by about 38% and 20%, respectively, from P0 to P1 (P intake, HP gradually decreased (P < 0.05) from P1 to P3 in connection with a reduction of the activity related HP. The evaporative heat loss represented 30% on the total heat loss on P0, and this proportion significantly increased on P1 (61%; P < 0.001) and remained constant thereafter. In conclusion, our results suggest that thermal heat acclimation in pigs is mainly related to a biphasic reduction of HP rather than a change in the ability of losing heat, and it did not significantly differ between RFI+ and RFI- lines despite a decreased HP in the latter ones.

  10. Effects of atmospheric variability on energy utilization and conservation. [Space heating energy demand modeling; Program HEATLOAD

    Reiter, E.R.; Johnson, G.R.; Somervell, W.L. Jr.; Sparling, E.W.; Dreiseitly, E.; Macdonald, B.C.; McGuirk, J.P.; Starr, A.M.


    Research conducted between 1 July 1975 and 31 October 1976 is reported. A ''physical-adaptive'' model of the space-conditioning demand for energy and its response to changes in weather regimes was developed. This model includes parameters pertaining to engineering factors of building construction, to weather-related factors, and to socio-economic factors. Preliminary testing of several components of the model on the city of Greeley, Colorado, yielded most encouraging results. Other components, especially those pertaining to socio-economic factors, are still under development. Expansion of model applications to different types of structures and larger regions is presently underway. A CRT-display model for energy demand within the conterminous United States also has passed preliminary tests. A major effort was expended to obtain disaggregated data on energy use from utility companies throughout the United States. The study of atmospheric variability revealed that the 22- to 26-day vacillation in the potential and kinetic energy modes of the Northern Hemisphere is related to the behavior of the planetary long-waves, and that the midwinter dip in zonal available potential energy is reflected in the development of blocking highs. Attempts to classify weather patterns over the eastern and central United States have proceeded satisfactorily to the point where testing of our method for longer time periods appears desirable.

  11. Effect of Health Literacy on the Utilization of Advance Directives Based on the Health Belief Model

    Henkelman, Wallace J.


    Research has demonstrated that only a small proportion of individuals in the United States complete advance directives as part of their planning for end-of-life care. This study sought to determine if health literacy is a significant factor in advance directive completion as has been posited by previous researchers. Analysis of the data collected…

  12. Aspen Plus® and economic modeling of equine waste utilization for localized hot water heating via fast pyrolysis.

    Hammer, Nicole L; Boateng, Akwasi A; Mullen, Charles A; Wheeler, M Clayton


    Aspen Plus(®) based simulation models have been developed to design a pyrolysis process for on-site production and utilization of pyrolysis oil from equine waste at the Equine Rehabilitation Center at Morrisville State College (MSC). The results indicate that utilization of all the available waste from the site's 41 horses requires a 6 oven dry metric ton per day (ODMTPD) pyrolysis system but it will require a 15 ODMTPD system for waste generated by an additional 150 horses at the expanded area including the College and its vicinity. For this a dual fluidized bed combustion reduction integrated pyrolysis system (CRIPS) developed at USDA's Agricultural Research Service (ARS) was identified as the technology of choice for pyrolysis oil production. The Aspen Plus(®) model was further used to consider the combustion of the produced pyrolysis oil (bio-oil) in the existing boilers that generate hot water for space heating at the Equine Center. The model results show the potential for both the equine facility and the College to displace diesel fuel (fossil) with renewable pyrolysis oil and alleviate a costly waste disposal problem. We predict that all the heat required to operate the pyrolyzer could be supplied by non-condensable gas and about 40% of the biochar co-produced with bio-oil. Techno-economic Analysis shows neither design is economical at current market conditions; however the 15 ODMTPD CRIPS design would break even when diesel prices reach $11.40/gal. This can be further improved to $7.50/gal if the design capacity is maintained at 6 ODMTPD but operated at 4950 h per annum.

  13. Ocean thermal energy conversion (OTEC) power system development utilizing advanced, high-performance heat transfer techniques. Volume 1. Conceptual design report


    The objective of this project is the development of a preliminary design for a full-sized, closed cycle, ammonia power system module for the 100 MWe OTEC Demonstration Plant. In turn, this Demonstration Plant is to demonstrate, by 1984, the operation and performance of an ocean thermal power plant having sufficiently advanced heat exchanger design to project economic viability for commercial utilization in the late 1980's and beyond. Included in this power system development are the preliminary designs for a proof-of-concept pilot plant and test article heat exchangers which are scaled in such a manner as to support a logically sequential, relatively low-cost development of the full-scale power system module. The conceptual designs are presented for the Demonstration Plant power module, the proof-of-concept pilot plant, and for a pair of test article heat exchangers. Costs associated with the design, development, fabrication, checkout, delivery, installation, and operation are included. The accompanying design and producibility studies on the full-scale power system module project the performance/economics for the commercial plant. This section of the report describes the full-size power system module, and summarizes the design parameters and associated costs for the Demonstration Plant module (prototype) and projects costs for commercial plants in production. The material presented is directed primarily toward the surface platform/ship basic reference hull designated for use during conceptual design; however, other containment vessels were considered during the design effort so that the optimum power system would not be unduly influenced or restricted. (WHK)

  14. Overview of direct use R&D at the Geo-Heat Center

    Lienau, P.J.


    Geo-Heat Center research, during the past year, on geothermal district heating and greenhouse projects is intended to improve the design and cost effectiveness of these systems. The largest geothermal district heating system in the U.S., proposed at Reno, is describe and is one of 271 collocated sites in western states could benefit from the research. The geothermal district heating research investigated a variety of factors that could reduce development cost for residential areas. Many greenhouse operators prefer the {open_quotes}bare tube{close_quotes} type heating system. As facilities using these types of heating systems expand they could benefit from peaking with fossil fuels. It is possible to design a geothermal heating system for only 60% of the peak heat loss of a greenhouse and still meet over 90% of the annual heat energy needs of the structure. The design and cost effectiveness of this novel approach is summarized.

  15. Open absorption heat pump for waste heat utilization in the forest industry. A study of technical and economic potential; Oeppen absorptionsvaermepump foer uppgradering av spillvaerme fraan skogsindustrin. Studie av teknisk och ekonomisk potential

    Westermark, Mats; Vidlund, Anna


    Waste heat from the forest industry is mainly humid air or humid flue gases with somewhat too low dew point for direct use as district heating or for other qualified purposes. Upgrading of the temperature by heat pumps is thus often necessary for the full use of the waste heat. This study evaluates an open absorption heat, based on hygroscopic condensation. The hygroscopic condenser has the potential to replace mechanical heat pumps or conventional absorption heat pumps (based on lithium bromide) for the upgrading of heat from humid gases. The goal for the project is to evaluate technology and potential for an open absorption heat pump for heat recovery from humid gases in the forest industry. In an open heat pump the humid gas is brought in direct contact with the hygroscopic liquid (whereas a conventional heat pump uses an intermediate circuit with evaporation of water in the evaporator). The direct contact makes it possible to recover the heat at a higher temperature than the dew point of the humid gas without the use of evaporator. The target group for the study is the forest industry and its suppliers of technology and knowledge. The study has been carried out in cooperation with representatives from the forest industry and from suppliers of equipment. The study shows that the forest industry has good potential to upgrade waste heat from humid air to district heating. The waste heat can be extracted from various humid gases such as exit air from paper machines, wood driers, green liquid quenchers and flue gases from soda boilers, mesa kilns, bark-fired boilers and gas engines. Hygroscopic condensation is considered to give economic and environmental advantages compared to conventional absorption heat pumps due to much less consumption of driving heat. An interesting special case is the regeneration of the hygroscopic medium by direct contact with hot flue gases and for this application a patent application has been filed. Upgrading of waste heat to process

  16. Direct utilization of geothermal resources field experiments at Monroe, Utah. Final report, July 14, 1978-July 13, 1981

    Blair, C.K.; Owen, L.B. (eds.)


    The City of Monroe, Utah undertook a project to demonstrate the economic and technical viability of utilizing a low temperature geothermal resource to provide space and hot water heating to commercial, municipal, and domestic users within the community. During the course of the project, resource development and assessment, including drilling of a production well, was successfully completed. Upon completion of the field development and assessment phase of the program and of a preliminary design of the district heating system, it was determined that the project as proposed was not economically viable. This was due to: (1) a significant increase in estimated capital equipment costs resulting from the general inflation in construction costs, the large area/low population density in Monroe, and a more remote fluid disposal well site than planned, could not balance increased construction costs, (2) a lower temperature resource than predicted, and (3) due to predicted higher pumping and operating costs. After a thorough investigation of alternatives for utilizing the resource, further project activities were cancelled because the project was no longer economical and an alternative application for the resource could not be found within the constraints of the project. The City of Monroe, Utah is still seeking a beneficial use for the 600 gpm, 164/sup 0/F geothermal well. A summary of project activities included.

  17. Workshop on Direct Contact Heat Transfer at the Solar Energy Research Institute

    Boehm, R


    to increase the use of direct contact processes, the National Science Foundation sup­ ported a workshop on direct contact heat transfer at the Solar Energy Research Insti­ tute in the summer of 1985. We served as organizers for this workshop, which em­ phasized an area of thermal engineering that, in our opinion, has great promise for the future, but has not yet reached the point of wide-spread commercial application. Hence, a summary of the state of knowledge at this point is timely. The workshop had a dual objective: 1. To summarize the current state of knowledge in such a form that industrial practi­ tioners can make use of the available information. 2. To indicate the research and development needed to advance the state-of-the-art, indicating not only what kind of research is needed, but also the industrial poten­ tial that could be realized if the information to be obtained through the proposed research activities were available.

  18. The evolution of plasma cholesterol: direct utility or a "spandrel" of hepatic lipid metabolism?

    Babin, Patrick J; Gibbons, Geoffrey F


    Fats provide a concentrated source of energy for multicellular organisms. The efficient transport of fats through aqueous biological environments raises issues concerning effective delivery to target tissues. Furthermore, the utilization of fatty acids presents a high risk of cytotoxicity. Improving the efficiency of fat transport while simultaneously minimizing the cytotoxic risk confers distinct selective advantages. In humans, most of the plasma cholesterol is associated with low-density lipoprotein (LDL), a metabolic by-product of very-low-density lipoprotein (VLDL), which originates in the liver. However, the functions of VLDL are not clear. This paper reviews the evidence that LDL arose as a by-product during the natural selection of VLDL. The latter, in turn, evolved as a means of improving the efficiency of diet-derived fatty acid storage and utilization, as well as neutralizing the potential cytotoxicity of fatty acids while conserving their advantages as a concentrated energy source. The evolutionary biology of lipid transport processes has provided a fascinating insight into how and why these VLDL functions emerged during animal evolution. As causes of historical origin must be separated from current utilities, our spandrel-LDL theory proposes that LDL is a spandrel of VLDL selection, which appeared non-adaptively and may later have become crucial for vertebrate fitness.

  19. Features and amenities of school playgrounds: A direct observation study of utilization and physical activity levels outside of school time

    Swayampakala Kamala


    Full Text Available Abstract Background A significant amount of research has examined whether park or playground availability is associated with physical activity. However, little research has examined whether specific features or amenities of parks or playgrounds, such as the number of unique types of playground equipment or the safety of the equipment is associated with utilization of the facility or physical activity levels while at the facility. There are no studies that use direct observation and a detailed park assessment to examine these associations. Methods Twenty urban schoolyards in the Midwest, ten of which were renovated, were included in this study. Using a detailed environmental assessment tool (i.e., Environmental Assessment of Public Recreation Spaces, information on a variety of playground attributes was collected. Using direct observation (i.e., System for Observing Play and Leisure Activity in Youth, the number of adults, girls and boys attending each schoolyard and their physical activity levels were recorded. Each schoolyard was observed ten times for 90 minutes each time outside of school hours. Clustered multivariable negative binomial regressions and linear regressions were completed to examine the association between playground attributes and utilization of the schoolyard and the proportion active on the playground, respectively. Effect modification by renovation status was also examined. Results At renovated schoolyards, the total number of play features was significantly associated with greater utilization in adults and girls; overall cleanliness was significantly associated with less utilization in girls and boys; and coverage/shade for resting features was significantly associated with greater utilization in adults and boys. At unrenovated schoolyards, overall safety was significantly associated with greater utilization in boys. No playground attribute was associated with the proportion active on the playground after adjusting for all

  20. Performance and efficiency evaluation and heat release study of a direct-injection stratified-charge rotary engine

    Nguyen, H. L.; Addy, H. E.; Bond, T. H.; Lee, C. M.; Chun, K. S.


    A computer simulation which models engine performance of the Direct Injection Stratified Charge (DISC) rotary engines was used to study the effect of variations in engine design and operating parameters on engine performance and efficiency of an Outboard Marine Corporation (OMC) experimental rotary combustion engine. Engine pressure data were used in a heat release analysis to study the effects of heat transfer, leakage, and crevice flows. Predicted engine data were compared with experimental test data over a range of engine speeds and loads. An examination of methods to improve the performance of the rotary engine using advanced heat engine concepts such as faster combustion, reduced leakage, and turbocharging is also presented.

  1. Heat pump technology economy analysis of waste heat utilization project in power plant%电厂中热泵余热利用工程的技术经济性分析



    通过热泵回收循环水余热并用于供热是一种具有极大经济和社会效益的低温余热回收方式。文章利用技术经济评价方法对采用三种不同型式热泵的低温余热利用方案进行经济性比较分析,从而确定最优方案。%Through heat pump to recover waste heat of circulating water and used for heating is a kind of low temperature waste heat recovery with great economic and social benefits. Using three different types of heat pump low temperature waste heat utilization with technical and economic evaluation method to do the economical comparison and analysis, thus determine the optimal solution, it made important contributions to establish reasonable plans.

  2. Partitioning of heat production in growing pigs as a tool to improve the determination of efficiency of energy utilization

    Etienne eLabussière


    Full Text Available In growing pigs, the feed cost accounts for more than 60% of total production costs. The determination of efficiency of energy utilization through calorimetry measurements is of importance to sustain suitable feeding practice. The objective of this paper is to describe a methodology to correct daily heat production (HP obtained from measurements in respiration chamber for the difference in energy expenditure related to physical activity between animals. The calculation is based on a preliminary published approach for partitioning HP between HP due to physical activity (AHP, thermic effect of feeding (TEF and basal metabolic rate (FHP. Measurements with male growing pigs (mean body weight: 115 kg which were surgically castrated (SC, castrated through immunization against GnRH (IC, or kept as entire male (EM were used as an example. Animals were fed the same diet ad libitum and were housed individually in two 12-m3 open-circuit respiration chambers during six days when fed ad libitum and one supplementary day when fasted. Physical activity was recorded through interruption of an infrared beam to detect standing and lying positions and with force transducers that recorded the mechanical force the animal exerted on the floor of the cage. Corrected AHP (AHPc, TEF (TEFc and HP (HPc were calculated to standardize the level of AHP between animals, assuming that the ratio between AHPc and ME intake should be constant. Inefficiency of energy utilization (sum of AHPc and TEFc was lower than the inefficiency estimated from the slope of the classical relationship between HPc and ME intake but was associated with higher requirements for maintenance. Results indicate that EM pigs had higher FHP but lower TEFc than IC and SC pigs. These results agree with the higher contents in viscera of EM pigs that stimulate their basal metabolic rate and to the reduced utilization of dietary protein to provide energy for maintenance energy requirements and fat deposition.

  3. The probability of containment failure by direct containment heating in Zion

    Pilch, M.M. [Sandia National Labs., Albuquerque, NM (United States); Yan, H.; Theofanous, T.G. [California Univ., Santa Barbara, CA (United States)


    This report is the first step in the resolution of the Direct Containment Heating (DCH) issue for the Zion Nuclear Power Plant using the Risk Oriented Accident Analysis Methodology (ROAAM). This report includes the definition of a probabilistic framework that decomposes the DCH problem into three probability density functions that reflect the most uncertain initial conditions (UO{sub 2} mass, zirconium oxidation fraction, and steel mass). Uncertainties in the initial conditions are significant, but our quantification approach is based on establishing reasonable bounds that are not unnecessarily conservative. To this end, we also make use of the ROAAM ideas of enveloping scenarios and ``splintering.`` Two causal relations (CRs) are used in this framework: CR1 is a model that calculates the peak pressure in the containment as a function of the initial conditions, and CR2 is a model that returns the frequency of containment failure as a function of pressure within the containment. Uncertainty in CR1 is accounted for by the use of two independently developed phenomenological models, the Convection Limited Containment Heating (CLCH) model and the Two-Cell Equilibrium (TCE) model, and by probabilistically distributing the key parameter in both, which is the ratio of the melt entrainment time to the system blowdown time constant. The two phenomenological models have been compared with an extensive database including recent integral simulations at two different physical scales. The containment load distributions do not intersect the containment strength (fragility) curve in any significant way, resulting in containment failure probabilities less than 10{sup {minus}3} for all scenarios considered. Sensitivity analyses did not show any areas of large sensitivity.

  4. Research and Application of Waste Heat Utilization Technology of Natural Gas Compressor in Xinjiang Oilfield%新疆油田天然气压缩机余热利用技术研究与应用

    习尚斌; 李泽伟; 钱崇林; 孙志勇; 邹志远


    新疆油田天然气压缩机以天然气为燃料压缩天然气增压外输,当机组排烟温度为370~400℃时,烟气余热未经回收利用,使排烟损失较大;同时缸体冷却水余热通过风冷器直接排放,造成压缩机组综合热能利用率低。结合处理站用热情况,对余热回收工艺技术进行了分析比较,提出了有针对性的余热回收解决方案。采用余热锅炉回收高温烟气余热,产生的蒸汽用于原油掺热;采用烟气冷凝器回收低温烟气余热用来加热锅炉补水;采用水-水换热器替代风冷器回收缸体冷却水余热,最大限度地回收压缩机余热;并根据余热利用项目的运行效果,做出经济技术分析。%The natural gas compressor in Xinjiang Oilfield uses natural gas as fuel for external transport natural gas compressing and boosting. On 370~400 ℃, smoke of the unit is with-out the use of waste heat,the smoke loss is great,besides the cylinder cooling heat discharg-es directly through the air cooler, the comprehensive heat energy utilization efficiency of the compressor unit is low. Based on the actual situation of processing station, using waste heat boiler to recover the waste heat of high temperature flue gas to produce steam and then heat the crude oil, using flue gas condenser to recover low temperature flue gas waste heat to heat boiler water, at the same time, using water-water heat exchanger instead of the air cooler to recover the waste heat of the cylinder cooling water, and the waste heat of compressor could be recovered to the utmost. According to the operating effect of waste heat utilization project, economic technical analysis could be made.

  5. Keratocyte fragments and cells utilize competing pathways to move in opposite directions in an electric field.

    Sun, Yaohui; Do, Hao; Gao, Jing; Zhao, Ren; Zhao, Min; Mogilner, Alex


    Sensing of an electric field (EF) by cells-galvanotaxis-is important in wound healing [1], development [2], cell division, nerve growth, and angiogenesis [3]. Different cell types migrate in opposite directions in EFs [4], and the same cell can switch the directionality depending on conditions [5]. A tug-of-war mechanism between multiple signaling pathways [6] can direct Dictyostelium cells to either cathode or anode. Mechanics of motility is simplest in fish keratocytes, so we turned to keratocytes to investigate their migration in EFs. Keratocytes sense electric fields and migrate to the cathode [7, 8]. Keratocyte fragments [9, 10] are the simplest motile units. Cell fragments from leukocytes are able to respond to chemotactic signals [11], but whether cell fragments are galvanotactic was unknown. We found that keratocyte fragments are the smallest motile electric field-sensing unit: they migrate to the anode, in the opposite direction of whole cells. Myosin II was essential for the direction sensing of fragments but not for parental cells, while PI3 kinase was essential for the direction sensing of whole cells but not for fragments. Thus, two signal transduction pathways, one depending on PI3K, another on myosin, compete to orient motile cells in the electric field. Galvanotaxis is not due to EF force and does not depend on cell or fragment size. We propose a "compass" model according to which protrusive and contractile actomyosin networks self-polarize to the front and rear of the motile cell, respectively, and the electric signal orients both networks toward cathode with different strengths.

  6. Manual for the thermal and hydraulic design of direct contact spray columns for use in extracting heat from geothermal brines

    Jacobs, H.R.


    This report outlines the current methods being used in the thermal and hydraulic design of spray column type, direct contact heat exchangers. It provides appropriate referenced equations for both preliminary design and detailed performance. The design methods are primarily empirical and are applicable for us in the design of such units for geothermal application and for application with solar ponds. Methods for design, for both preheater and boiler sections of the primary heat exchangers, for direct contact binary powers plants are included. 23 refs., 8 figs.

  7. Introducing a novel method to estimate the total heat transfer coefficient inside irregular-shape cavities utilizing thermoelectric modules; Special application in solar engineering

    Asadi, Amin; Rahbar, Nader; Rezaniakolaei, Alireza


    The main objective of the present study is to introduce a novel method to measure the total heat transfer coefficient inside irregular-shape cavities, used in solar applications, utilizing thermoelectric modules. Applying mathematical and thermodynamics modeling, the governing equations related...... transfer coefficient inside irregular-shape cavities. The average deviation between experimental data and the output of the proposed equation is approximately 9 %, which shows the good ability of the equation in estimating the total heat transfer coefficient....

  8. Design methodologies for energy conservation and passive heating of buildings utilizing improved building components. Progress report No. 3, January 15--April 15, 1978

    Habraken, N.J.; Johnson, T.E.


    The recently completed MIT Solar Building 5 demonstrates direct gain solar space heating through the use of new architectural finish materials. February 1978 measurements are summarized. Results indicate the building performed nearly as expected.

  9. Developmentally regulated SMAD2 and SMAD3 utilization directs activin signalling outcomes

    Itman, Catherine; Small, Chris; Griswold, Michael; Nagaraja, Ankur K.; Matzuk, Martin M.; Brown, Chester; Jans, David A.; Loveland, Kate L.


    Activin is required for testis development. Activin signals via the phosphorylation and nuclear accumulation of SMAD2 and SMAD3. We present novel findings of developmentally regulated activin signalling leading to specific transcriptional outcomes in testicular Sertoli cells. In immature, proliferating, Sertoli cells, activin A induces nuclear accumulation of SMAD3, but not SMAD2, although both proteins become phosphorylated. In post-mitotic differentiating cells, both SMAD proteins accumulate in the nucleus. Furthermore, immature Sertoli cells are sensitive to activin dosage; higher concentrations induce maximal SMAD3 nuclear accumulation and a small increase in nuclear SMAD2. Microarray analysis identified distinct transcriptional outcomes correlating with differential SMAD utilization and new activin target genes, including Gja1 and Serpina5, which are essential for Sertoli cell development and male fertility. In transgenic mice with altered activin bioactivity that display fertility phenotypes, Gja1 and Serpina5 are significantly altered. Thus, differential SMAD utilization in response to activin features during Sertoli cell maturation. PMID:19517569

  10. Expanding Geothermal Resource Utilization through Directed Research, Education, and Public Outreach

    Calvin, Wendy [Univ. of Nevada, Reno, NV (United States)


    The Great Basin Center for Geothermal Energy (GBCGE or the Center) was established at the University of Nevada, Reno (UNR) in May 2000 to promote research and utilization of geothermal resources. The Center received funding through this grant to promote increased geothermal development in the Great Basin, with most of the funding used for peerreviewed research. Funding to the Center and work under the contract were initiated in March 2002, with supplemental funding in subsequent years. The Center monitored the research projects that were competitively awarded in a series of proposal calls between 2002 and 2007. Peer-reviewed research promoted identification and utilization of geothermal resources in Nevada. Projects used geology, geochemistry, geophysics, remote sensing, and the synthesis of multi-disciplinary information to produce new models of geothermal systems in the Western U.S. and worldwide. Funds were also used to support graduate student research and training. Part of the grant was used to support public outreach activities, including webpages, online maps and data resources, and informational workshops for stakeholders.

  11. Utilization direction of industrial raw products built-up in power station ash dumps

    Lihach Snejana A.


    Full Text Available Nowadays hundreds million tons of ash and slag waste (ASW is produced in Russia yearly. Large territories are needed in order to store such a big waste volume. Besides, it is necessary to conduct special engineering and ecological work at the design and usage stages of this structure. The goal of the research is to outline acceptable ASW utilization methods accumulated in coal burning power station ash dumps and to determine the order of activities to solve the problem. The research methods: experimental where Kansk-Achinsk and Kuznetsk coals are the object of the research. Besides, review of relevant to the problem literature and normative documentation was done to determine activities order, possible ways and limitations of the problem solving. We elucidated that ASW transportation to depleted coal quarries to restore them is essential to arrange in order to solve the problem of ASW utilization. As to new produced ASW, they should be divided into groups according to application field (mostly in construction. The groups correspond to boiler unit load operation. After coal combustion ash is stored in special places (reservoirs, silos. Therefore modern boiler unit might be seen as a production complex of steam and ash and slag material of an adequate quality.

  12. Prekindergarten Children's Executive Functioning Skills and Achievement Gains: The Utility of Direct Assessments and Teacher Ratings

    Fuhs, Mary Wagner; Farran, Dale Clark; Nesbitt, Kimberly Turner


    An accumulating body of evidence suggests that young children who exhibit greater executive functioning (EF) skills in early childhood also achieve more academically. The goal of the present study was to examine the unique contributions of direct assessments and teacher ratings of children's EF skills at the beginning of prekindergarten (pre-k) to…

  13. Fossil fuel saving through a direct solar energy water heating system

    Michels, Ademar; Dias Mayer, Flavio; Gallon, Roger; Hoffmann, Ronaldo; Tiago Serafini, Seimur [Federal University of Santa Maria, Santa Maria-RS (Brazil)


    The global warming and energy crisis is motivating the search for sustainable power sources. The objective of this work is to analyze the economic return and quantify the reduction in the emission of pollutants, when low-cost solar collectors are used as a partial substitute for a boiler that uses fuel oil as the energy source, in order to heat water for the swimming pools of the Physical Education Center, Federal University of Santa Maria. The collectors are made from PVC and other easily acquired materials. The estimations for energy saving are based on a collecting area of 182 m{sup 2}. From knowledge of the collectors' efficiency, the mathematical demonstration shows a fuel oil saving of 13,174 kg, representing 24% of the total amount consumed per annum. The investment required for the construction and installation of the collectors is US$ 6,445 and the estimated useful live is five years. The internal rate of return is 30%. The emission of pollutants is reduced by a considerable amount of 41,213 kg CO{sub 2}equivalent/year. The use of direct sun energy as an alternative power source represents a significant economic interest as well as contributing to the mitigation of greenhouse gases. (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  14. Characterizing U.S. Heat Demand Market for Potential Application of Geothermal Direct Use

    McCabe, Kevin; Gleason, Michael; Reber, Tim; Young, Katherine R.


    In this paper, we assess the U.S. demand for low-temperature thermal energy at the county resolution for four major end-use sectors: residential buildings, commercial buildings, manufacturing facilities, and agricultural facilities. Existing, publicly available data on the U.S. thermal demand market are characterized by coarse spatial resolution, with assessments typically at the state-level or larger. For many uses, these data are sufficient; however, our research was motivated by an interest in assessing the potential demand for direct use (DU) of low-temperature (30 degrees to 150 degrees C) geothermal heat. The availability and quality of geothermal resources for DU applications are highly spatially heterogeneous; therefore, to assess the potential market for these resources, it is necessary to understand the spatial variation in demand for low-temperature resources at a local resolution. This paper presents the datasets and methods we used to develop county-level estimates of the thermal demand for the residential, commercial, manufacturing, and agricultural sectors. Although this analysis was motivated by an interest in geothermal energy deployment, the results are likely to have broader applications throughout the energy industry. The county-resolution thermal demand data developed in this study for four major U.S. sectors may have far-reaching implications for building technologies, industrial processes, and various distributed renewable energy thermal resources (e.g. biomass, solar).

  15. Direct heat resource assessment: Phase II, year 1. Final report, February 1, 1979-January 31, 1980

    Thomas, D.M.; Cox, M.E.; Kauahikaua, J.P.; Mattice, M.D.


    During 1979 reconnaissance field surveys were conducted on the islands of Hawaii, Maui, and Oahu with the objective of confirming groundwater chemical data and geophysical data compiled during the preliminary regional assessment of Phase I of the Direct Heat Resource Assessment Program. The exploration techniques applied include (1) groundwater chemistry, (2) mercury-radon surveys, (3) isotopic composition of groundwaters, (4) time domain electromagnetics, and (5) Schlumberger resistivity surveys. The results of these surveys can be classified as follows: (1) Hawaii: Kailua-Kona, strong geochemical anomalies; Kawaihae, strong geophysical anomalies, moderate to strong geochemical anomalies; Hualalai northwest rift, weak geochemical and moderate geophysical anomalies; South Point, moderate to weak geophysical anomalies; Hualalai southeast rift, weak geophysical anomalies; Keaau, weak geophysical and geochemical anomalies; (2) Maui: Haiku-Paia, strong geochemical anomalies; Olowalu-Ukamehame canyons, moderate to strong geochemical and geophysical anomalies; Lahaina, weak geochemical and geophysical anomalies; (3) Oahu: Lualualei, moderate to strong geochemical and geophysical anomalies; Waimanalo-Maunawili, insufficient data.

  16. MELCOR 1.8.2 Assessment: IET direct containment heating tests

    Kmetyk, L.N.


    MELCOR is a fully integrated, engineering-level computer code, being developed at Sandia National Laboratories for the USNRC, that models the entire spectrum of severe accident phenomena in a unified framework for both BWRs and PWRS. As part of an ongoing assessment program, the MELCOR computer code has been used to analyze several of the IET direct containment heating experiments done at 1:10 linear scale in the Surtsey test facility at Sandia and at 1:40 linear scale in the corium-water thermal interactions (CWTI) COREXIT test facility at Argonne National Laboratory. These MELCOR calculations were done as an open post-test study, with both the experimental data and CONTAIN results available to guide the selection of code input. Basecase MELCOR results are compared to test data in order to evaluate the new HPME DCH model recently added in MELCOR version 1.8.2. The effect of various user-input parameters in the HPME model, which define both the initial debris source and the subsequent debris interaction, were investigated in sensitivity studies. In addition, several other non-default input modelling changes involving other MELCOR code packages were required in our IET assessment analyses in order to reproduce the observed experiment behavior. Several calculations were done to identify whether any numeric effects exist in our DCH IET assessment analyses.

  17. Direct Utilization of Liquid Fuels in SOFC for Portable Applications: Challenges for the Selection of Alternative Anodes

    Massimiliano Cimenti


    Full Text Available Solid oxide fuel cells (SOFC have the advantage of being able to operate with fuels other than hydrogen. In particular, liquid fuels are especially attractive for powering portable applications such as small power generators or auxiliary power units, in which case the direct utilization of the fuel would be convenient. Although liquid fuels are easier to handle and transport than hydrogen, their direct use in SOFC can lead to anode deactivation due to carbon formation, especially on traditional nickel/yttria stabilized zirconia (Ni/YSZ anodes. Significant advances have been made in anodic materials that are resistant to carbon formation but often these materials are less electrochemically active than Ni/YSZ. In this review the challenges of using liquid fuels directly in SOFC, in terms of gas-phase and catalytic reactions within the anode chamber, will be discussed and the alternative anode materials so far investigated will be compared.

  18. Extending the utility of [Pd(NHC)(cinnamyl)Cl] precatalysts: Direct arylation of heterocycles

    Anthony R Martin; Anthony Chartoire; Slawin, Alexandra M. Z.; Nolan, Steven P


    The use of [Pd(NHC)(cinnamyl)Cl] precatalysts in the direct arylation of heterocycles has been investigated. Among four different precatalysts, [Pd(SIPr)(cinnamyl)Cl] proved to be the most efficient promoter of the reaction. The C–H functionalization of sulfuror nitrogen-containing heterocycles has been achieved at low catalyst loadings. These catalyst charges range from 0.1 to 0.01 mol % palladium. Publisher PDF Peer reviewed

  19. Biocatalytic anode for glucose oxidation utilizing carbon nanotubes for direct electron transfer with glucose oxidase

    Vaze, Abhay; Hussain, Nighat; Tang, Chi [Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060 (United States); Leech, Donal [School of Chemistry, National University of Ireland, Galway (Ireland); Rusling, James [Department of Chemistry, University of Connecticut, Storrs, CT 06269-3060 (United States); Department of Cell Biology, University of Connecticut Health Center, Farmington, CT 06032 (United States); School of Chemistry, National University of Ireland, Galway (Ireland)


    Covalently linked layers of glucose oxidase, single-wall carbon nanotubes and poly-L-lysine on pyrolytic graphite resulted in a stable biofuel cell anode featuring direct electron transfer from the enzyme. Catalytic response observed upon addition of glucose was due to electrochemical oxidation of FADH{sub 2} under aerobic conditions. The electrode potential depended on glucose concentration. This system has essential attributes of an anode in a mediator-free biocatalytic fuel cell. (author)

  20. Directional biases reveal utilization of arm's biomechanical properties for optimization of motor behavior.

    Goble, Jacob A; Zhang, Yanxin; Shimansky, Yury; Sharma, Siddharth; Dounskaia, Natalia V


    Strategies used by the CNS to optimize arm movements in terms of speed, accuracy, and resistance to fatigue remain largely unknown. A hypothesis is studied that the CNS exploits biomechanical properties of multijoint limbs to increase efficiency of movement control. To test this notion, a novel free-stroke drawing task was used that instructs subjects to make straight strokes in as many different directions as possible in the horizontal plane through rotations of the elbow and shoulder joints. Despite explicit instructions to distribute strokes uniformly, subjects showed biases to move in specific directions. These biases were associated with a tendency to perform movements that included active motion at one joint and largely passive motion at the other joint, revealing a tendency to minimize intervention of muscle torque for regulation of the effect of interaction torque. Other biomechanical factors, such as inertial resistance and kinematic manipulability, were unable to adequately account for these significant biases. Also, minimizations of jerk, muscle torque change, and sum of squared muscle torque were analyzed; however, these cost functions failed to explain the observed directional biases. Collectively, these results suggest that knowledge of biomechanical cost functions regarding interaction torque (IT) regulation is available to the control system. This knowledge may be used to evaluate potential movements and to select movement of "low cost." The preference to reduce active regulation of interaction torque suggests that, in addition to muscle energy, the criterion for movement cost may include neural activity required for movement control.

  1. Calculation of the yearly energy performance of heating systems based on the European Building Energy Directive and related CEN Standards

    Olesen, Bjarne W.; de Carli, Michele


    According to the Energy Performance of Buildings Directive (EPBD) all new European buildings (residential, commercial, industrial, etc.) must since 2006 have an energy declaration based on the calculated energy performance of the building, including heating, ventilating, cooling and lighting...... systems. This energy declaration must refer to the primary energy or CO2 emissions. The European Organization for Standardization (CEN) has prepared a series of standards for energy performance calculations for buildings and systems. This paper presents related standards for heating systems. The relevant...... CEN-standards are presented and a sample calculation of energy performance is made for a small single family house, an office building and an industrial building in three different geographical locations: Stockholm, Brussels, and Venice. The additional heat losses from heating systems can be 10...

  2. Radiation heat transfer model for complex superalloy turbine blade in directional solidification process based on finite element method

    Dun-ming Liao


    Full Text Available For the sake of a more accurate shell boundary and calculation of radiation heat transfer in the Directional Solidification (DS process, a radiation heat transfer model based on the Finite Element Method (FEM is developed in this study. Key technologies, such as distinguishing boundaries automatically, local matrix and lumped heat capacity matrix, are also stated. In order to analyze the effect of withdrawing rate on DS process, the solidification processes of a complex superalloy turbine blade in the High Rate Solidification (HRS process with different withdrawing rates are simulated; and by comparing the simulation results, it is found that the most suitable withdrawing rate is determined to be 5.0 mm昺in-1. Finally, the accuracy and reliability of the radiation heat transfer model are verified, because of the accordance of simulation results with practical process.

  3. Transverse heat transfer coefficient in the dual channel ITER TF CICCs. Part III: Direct method of assessment

    Lewandowska, Monika; Malinowski, Leszek


    The data resulting from the thermal-hydraulic test of the ITER TF CICC are used to determine the flow partition and the overall effective heat transfer coefficient (hBC) between bundle and central channel in a direct way, i.e. by analysis of the heat transfer between both flow channels, based on the mass and energy balance equations and the readings of thermometers located inside the cable. In cases without a local heat source in the considered cable segment the obtained hBC values were consistent with those obtained in earlier studies by analysis of experimental data using indirect methods. It was also observed that the transverse heat transfer was strongly enhanced in a cable segment heated from outside. This phenomenon results from the mass transfer from the bundle region to the central channel. The experimental hBC data obtained for the case without a heat source in the considered segment were also compared with those calculated using various heat transfer correlations.

  4. Validation and scopolamine-reversal of latent learning in the water maze utilizing a revised direct platform placement procedure.

    Malin, David H; Schaar, Krystal L; Izygon, Jonathan J; Nghiem, Duyen M; Jabitta, Sikirat Y; Henceroth, Mallori M; Chang, Yu-Hsuan; Daggett, Jenny M; Ward, Christopher P


    The Morris water maze is routinely used to explore neurobiological mechanisms of working memory. Humans can often acquire working memory relevant to performing a task by mere sensory observation, without having to actually perform the task followed by reinforcement. This can be modeled in the water maze through direct placement of a rat on the escape platform so that it can observe the location, and then assessing the subject's performance in swimming back to the platform. However, direct placement procedures have hardly been studied for two decades, reflecting a controversy about whether direct placement resulted in sufficiently rapid and direct swims back to the platform. In the present study, utilizing revised training methods, a more comprehensive measure of trajectory directness, a more rigorous sham-trained control procedure and an optimal placement-test interval, rats swam almost directly back to the platform in under 4s, significantly more quickly and directly than sham-trained subjects. Muscarinic cholinergic mechanisms, which are inactivated by scopolamine, are essential to memory for standard learning paradigms in the water maze. This experiment determined whether this would also be true for latent learning. ANOVA revealed significant negative effects of scopolamine on both speed and accuracy of trajectory, as well as significant positive effects of direct placement training vs. sham-training. In a probe trial, placement-trained animals without scopolamine spent significantly more time and path length in the target quadrant than trained rats with scopolamine and sham-trained rats without scopolamine. Scopolamine impairments are likely due to effects on memory, since the same dose had little effect on performance with a visible platform. The revised direct placement model offers a means of further comparing the neural mechanisms of latent learning with those of standard instrumental learning.


    Suthar, K. J.; Lurie, Alexander M.; Den Hartog, P.


    Heat pipes and vapour chambers work on heat exchange phenomena of two-phase flow and are widely used for in-dustrial and commercial applications. These devices offer very high effective thermal conductivities (5,000-200,000 W/m/K) and are adaptable to various sizes, shapes, and ori-entations. Although they have been found to be an excel-lent thermal management solution for laptops, satellites, and many things in-between, heat pipes and vapour cham-bers have yet to be adopted for use at particle accelerator facilities where they offer the possibility of more compact and more efficient means to remove heat from unwanted synchrotron radiation. As with all technologies, there are inherent limitations. Foremost, they are limited by practi-cality to serve as local heat transfer devices; heat transfer over long distances is likely best provided by other means. Heat pipes also introduce unique failure modes which must be considered.

  6. Separate effects tests on hydrogen combustion during direct containment heating events

    Meyer, L.; Albrecht, G.; Kirstahler, M.; Schwall, M.; Wachter, E.


    In the frame of severe accident research for light water reactors Forschungszentrum Karlsruhe (FZK/IKET) operates the facilities DISCO-C and DISCO-H since 1998, conceived to investigate the direct containment heating (DCH) issue. Previous DCH experiments have investigated the corium dispersion and containment pressurization during DCH in different European reactor geometries using an iron-alumina melt and steam as model fluids. The analysis of these experiments showed that the containment was pressurized by the debris-to-gas heat transfer but also to a large part by hydrogen combustion. The need was identified to better characterize the hydrogen combustion during DCH. To address this issue separate effect tests in the DISCO-H facility were conducted. These tests reproduced phenomena occurring during DCH (injection of a hot steam-hydrogen mixture jet into the containment and ignition of the air-steam-hydrogen mixture) with the exception of corium dispersion. The effect of corium particles as igniters was simulated using sparkler systems. The data will be used to validate models in combustion codes and to extrapolate to prototypic scale. Tests have been conducted in the DISCO-H facility in two steps. First a small series of six tests was done in a simplified geometry to study fundamental parameters. Then, two tests were done with a containment geometry subdivided into a subcompartment and the containment dome. The test conditions were as follows: As initial condition in the containment an atmosphere was used either with air or with a homogeneous air-steam mixture containing hydrogen concentrations between 0 and 7 mol%, temperatures around 100 C and pressure at 2 bar (representative of the containment atmosphere conditions at vessel failure). Injection of a hot steam-hydrogen jet mixture into the reactor cavity pit at 20 bar, representative of the primary circuit blow down through the vessel and hydrogen produced during this phase. The most important variables

  7. An experimental approach to determine the heat transfer coefficient in directional solidification furnaces

    Banan, Mohsen; Gray, Ross T.; Wilcox, William R.


    The heat transfer coefficient between a molten charge and its surroundings in a Bridgman furnace was experimentally determined using in-situ temperature measurement. The ampoule containing an isothermal melt was suddenly moved from a higher temperature zone to a lower temperature zone. The temperature-time history was used in a lumped-capacity cooling model to evaluate the heat transfer coefficient between the charge and the furnace. The experimentally determined heat transfer coefficient was of the same order of magnitude as the theoretical value estimated by standard heat transfer calculations.

  8. Solar energy utilization in the direct photocarboxylation of 2,3-dihydrofuran using CO2.

    Aresta, Michele; Dibenedetto, Angela; Baran, Tomasz; Wojtyła, Szymon; Macyk, Wojciech


    The conversion of CO2 into high energy products (fuels) and the direct carboxylation of C-H bonds require a high energy input. Energy cannot be derived from fossil carbon, in this case. Solar energy can be used instead, with a low environmental impact and good profit. We have studied the use of white light or solar energy in the photoreduction of CO2 and in photocarboxylation reactions, using different semiconductors modified at their surface. Two examples of reduction of CO2 to methanol and CO will be shortly discussed, and two cases of carboxylation of organic substrates. The case of carboxylation of 2,3-dihydrofuran will be discussed in detail.

  9. Proceedings of the advanced research and technology development direct utilization, instrumentation and diagnostics contractors' review meeting

    Geiling, D.W. (USDOE Morgantown Energy Technology Center, WV (USA)); Goldberg, P.M. (eds.) (USDOE Pittsburgh Energy Technology Center, PA (USA))


    The 1990 Advanced Research and Technology Development (AR TD) Direct Utilization, and Instrumentation and Diagnostics Contractors Review Meeting was held September 16--18, 1990, at the Hyatt at Chatham Center in Pittsburgh, PA. The meeting was sponsored by the US Department of Energy (DOE), Office of Fossil Energy, and the Pittsburgh and Morgantown Energy Technology Centers. Each year the meeting provides a forum for the exchange of information among the DOE AR TD contractors and interested parties. This year's meeting was hosted by the Pittsburgh Energy Technology Center and was attended by 120 individuals from industry, academia, national laboratories, and other governmental agencies. Papers were presented on research addressing coal surface, science, devolatilization and combustion, ash behavior, emission controls for gases particulates, fluid bed combustion and utilization in diesels and turbines. Individual reports are processed separately for the data bases.

  10. Future directions in psychological assessment: combining evidence-based medicine innovations with psychology's historical strengths to enhance utility.

    Youngstrom, Eric A


    Assessment has been a historical strength of psychology, with sophisticated traditions of measurement, psychometrics, and theoretical underpinnings. However, training, reimbursement, and utilization of psychological assessment have been eroded in many settings. Evidence-based medicine (EBM) offers a different perspective on evaluation that complements traditional strengths of psychological assessment. EBM ties assessment directly to clinical decision making about the individual, uses simplified Bayesian methods explicitly to integrate assessment data, and solicits patient preferences as part of the decision-making process. Combining the EBM perspective with psychological assessment creates a hybrid approach that is more client centered, and it defines a set of applied research topics that are highly clinically relevant. This article offers a sequence of a dozen facets of the revised assessment process, along with examples of corollary research studies. An eclectic integration of EBM and evidence-based assessment generates a powerful hybrid that is likely to have broad applicability within clinical psychology and enhance the utility of psychological assessments.

  11. Directed sample interrogation utilizing an accurate mass exclusion-based data-dependent acquisition strategy (AMEx).

    Rudomin, Emily L; Carr, Steven A; Jaffe, Jacob D


    The ability to perform thorough sampling is of critical importance when using mass spectrometry to characterize complex proteomic mixtures. A common approach is to reinterrogate a sample multiple times by LC-MS/MS. However, the conventional data-dependent acquisition methods that are typically used in proteomics studies will often redundantly sample high-intensity precursor ions while failing to sample low-intensity precursors entirely. We describe a method wherein the masses of successfully identified peptides are used to generate an accurate mass exclusion list such that those precursors are not selected for sequencing during subsequent analyses. We performed multiple concatenated analytical runs to sample a complex cell lysate, using either accurate mass exclusion-based data-dependent acquisition (AMEx) or standard data-dependent acquisition, and found that utilization of AMEx on an ESI-Orbitrap instrument significantly increases the total number of validated peptide identifications relative to a standard DDA approach. The additional identified peptides represent precursor ions that exhibit low signal intensity in the sample. Increasing the total number of peptide identifications augmented the number of proteins identified, as well as improved the sequence coverage of those proteins. Together, these data indicate that using AMEx is an effective strategy to improve the characterization of complex proteomic mixtures.

  12. Nitroreductase gene-directed enzyme prodrug therapy: insights and advances toward clinical utility.

    Williams, Elsie M; Little, Rory F; Mowday, Alexandra M; Rich, Michelle H; Chan-Hyams, Jasmine V E; Copp, Janine N; Smaill, Jeff B; Patterson, Adam V; Ackerley, David F


    This review examines the vast catalytic and therapeutic potential offered by type I (i.e. oxygen-insensitive) nitroreductase enzymes in partnership with nitroaromatic prodrugs, with particular focus on gene-directed enzyme prodrug therapy (GDEPT; a form of cancer gene therapy). Important first indications of this potential were demonstrated over 20 years ago, for the enzyme-prodrug pairing of Escherichia coli NfsB and CB1954 [5-(aziridin-1-yl)-2,4-dinitrobenzamide]. However, it has become apparent that both the enzyme and the prodrug in this prototypical pairing have limitations that have impeded their clinical progression. Recently, substantial advances have been made in the biodiscovery and engineering of superior nitroreductase variants, in particular development of elegant high-throughput screening capabilities to enable optimization of desirable activities via directed evolution. These advances in enzymology have been paralleled by advances in medicinal chemistry, leading to the development of second- and third-generation nitroaromatic prodrugs that offer substantial advantages over CB1954 for nitroreductase GDEPT, including greater dose-potency and enhanced ability of the activated metabolite(s) to exhibit a local bystander effect. In addition to forging substantial progress towards future clinical trials, this research is supporting other fields, most notably the development and improvement of targeted cellular ablation capabilities in small animal models, such as zebrafish, to enable cell-specific physiology or regeneration studies.

  13. [Effects of advance visual cue utilization on anticipation of ball direction].

    Miyoshi, Satoko; Mori, Shuji; Hirose, Nobuyuki


    We examined skill-based differences in the anticipation of ball direction during the catching of a grounder in baseball. In Experiment 1, we used film stimuli which included a sequence of pitching and hitting action from the shortstop's customary perspective, and participants judged the ball's direction (left or right). Also, we used white-circle stimuli, and participants reported whether the circle was displaced to the left or to the right. Baseball players responded faster than non-players in the film task, but there was no significant difference between the two groups in the white-circle task. In Experiment 2, we used film stimuli which were cut off at four different temporal occlusion periods to examine the time of extraction of important visual cues. Accuracy exceeded the chance level prior to the bat-ball contact in both groups, but was earlier for players than for non-players. Our results suggest that players may extract anticipatory visual cues more effectively and earlier than non-players.

  14. Direct utilization of geothermal energy resources in food processing. Final report, May 17, 1978-May 31, 1982

    Austin, J.C.


    In early 1978 financial assistance was granted for a project to utilize geothermal energy at Ore-Ida Foods, Inc.'s food processing plant in Ontario, Oregon. Specifically, the project included exploring, testing, and developing the potential geothermal resource; retrofitting the existing gas/oil-fired steam system; utilizing the geothermal resource for food processing, space heating, and hot potable water; and injecting the spent geothermal water back into a disposal well. Based on preliminary investigations which indicated the presence of a local geothermal resource, drilling began in August 1979. Although the anticipated resource temperature of 380/sup 0/F was reached at total well depth (10,054 feet), adequate flow to meet processing requirements could not be obtained. Subsequent well testing and stimulation techniques also failed to produce the necessary flow, and the project was eventually abandoned. However, throughout the duration of the project, all activities were carefully monitored and recorded to ensure the program's value for future evaluation. This report presents a culmination of data collected during the Ore-Ida project.

  15. Power plant waste heat utilization in aquaculture. Annual report No. 1, 1 November 1976-31 October 1977


    A pilot aquaculture facility utilizing heated river water from condenser cooling (PSEandG's Mercer Generating Station, Trenton, New Jersey) is being used to culture the freshwater shrimp (Macrobrachium rosenbergii) and American eel (Anguilla rostrata) during the warmer months of the year, and rainbow trout (Salmo gairdneri) during the colder months near Trenton, New Jersey. Twelve thousand trout were harvested from the last grow-out season. During June, 1977, juvenile shrimp 4.5 cm long were stocked at 31/sq m of total surface area in an outdoor raceway. By the end of September, 1977, the shrimp reached an average length of 7.9 cm at 11/sq m and suffered a high mortality of 58 percent. The density of 11/sq m confirms previous results in preceding years. Laboratory tests are also being conducted at Rutgers University to develop shrimp feeds with supplemented amino acids, and improve existing commercial shrimp feeds by incorporating better food binders which do not allow these food pellets to disintegrate in water as quickly.

  16. Utilization of Field Enhancement in Plasmonic Waveguides for Subwavelength Light-Guiding, Polarization Handling, Heating, and Optical Sensing

    Daoxin Dai


    Full Text Available Plasmonic nanostructures have attracted intensive attention for many applications in recent years because of the field enhancement at the metal/dielectric interface. First, this strong field enhancement makes it possible to break the diffraction limit and enable subwavelength optical waveguiding, which is desired for nanophotonic integrated circuits with ultra-high integration density. Second, the field enhancement in plasmonic nanostructures occurs only for the polarization mode whose electric field is perpendicular to the metal/dielectric interface, and thus the strong birefringence is beneficial for realizing ultra-small polarization-sensitive/selective devices, including polarization beam splitters, and polarizers. Third, plasmonic nanostructures provide an excellent platform of merging electronics and photonics for some applications, e.g., thermal tuning, photo-thermal detection, etc. Finally, the field enhancement at the metal/dielectric interface helps a lot to realize optical sensors with high sensitivity when introducing plasmonic nanostrutures. In this paper, we give a review for recent progresses on the utilization of field enhancement in plasmonic nanostructures for these applications, e.g., waveguiding, polarization handling, heating, as well as optical sensing.

  17. 电站烟气余热利用系统浅析%Initial Analysis on Flue Gas Waste Heat Utilization System in Power Plant

    陈晓文; 杜文智; 熊英莹; 谭厚章


    With the growing use of energy and awareness of environmental protection around the world, more and more attention has been attracted by the utilization of waste heat from flue gas. In order to provide theoretical guidance for cascade utilization of waste heat in power plant efficiently and reasonably by setting a flue gas waste heat utilization system for our country, this article not only showed the design criteria of the system, but also analyzed heat transfer equation, ways of heat transfer, types of cold source and setting locations of that.%随着全球范围内能源需求量持续增加,环保意识不断增强,电站烟气余热利用越来越受到重视。本文介绍了电站烟气余热利用系统的设计原则,并分析了烟气余热利用系统的换热方程、换热方式、冷源种类以及可设置位置,可以作为我国电站设置烟气余热利用系统、高效合理地梯级回收烟气余热过程的参考。

  18. A Novel approach for Low temperature Condenser waste heat Utilization in winter air conditioning for overall Performance Improvement of a Power Plant in Northern India

    Rajendra Kumar Yadav


    Full Text Available The objective of this paper to highlight the scope of utilization of waste heat of condenser for winter air conditioning in and around thermal power stations. The vast amount of low grade condenser waste heat can be used to provide winter air conditioning by utilizing the existing system of year round central air conditioning without additional heavy capital expenditure .The present case study is about North India where peak winter lasts about 90 days . The waste heat utilization for winter conditioning will not only save large amount of electrical energy being used in electrical heaters but also generate additional revenue by selling out extra/spared power ,increase thermal energy utilization ,improve performance of the plant .The novel method of winter air conditioning will also reduce the heat load of the cooling towers, avoid pumping and blow down power as the returning water from air conditioning system can be used as blow down to maintain cooling water parameters in the plant.

  19. Vibrio cholerae utilizes direct sRNA regulation in expression of a biofilm matrix protein.

    Tianyan Song

    Full Text Available Vibrio cholerae biofilms contain exopolysaccharide and three matrix proteins RbmA, RbmC and Bap1. While much is known about exopolysaccharide regulation, little is known about the mechanisms by which the matrix protein components of biofilms are regulated. VrrA is a conserved, 140-nt sRNA of V. cholerae, whose expression is controlled by sigma factor σE. In this study, we demonstrate that VrrA negatively regulates rbmC translation by pairing to the 5' untranslated region of the rbmC transcript and that this regulation is not stringently dependent on the RNA chaperone protein Hfq. These results point to VrrA as a molecular link between the σE-regulon and biofilm formation in V. cholerae. In addition, VrrA represents the first example of direct regulation of sRNA on biofilm matrix component, by-passing global master regulators.

  20. Oligodendrocyte Progenitor Cells Directly Utilize Lactate for Promoting Cell Cycling and Differentiation.

    Ichihara, Yoshinori; Doi, Toru; Ryu, Youngjae; Nagao, Motoshi; Sawada, Yasuhiro; Ogata, Toru


    Oligodendrocyte progenitor cells (OPCs) undergo marked morphological changes to become mature oligodendrocytes, but the metabolic resources for this process have not been fully elucidated. Although lactate, a metabolic derivative of glycogen, has been reported to be consumed in oligodendrocytes as a metabolite, and to ameliorate hypomyelination induced by low glucose conditions, it is not clear about the direct contribution of lactate to cell cycling and differentiation of OPCs, and the source of lactate for remyelination. Therefore, we evaluated the effect of 1,4-dideoxy-1,4-imino-d-arabinitol (DAB), an inhibitor of the glycogen catabolic enzyme glycogen phosphorylase, in a mouse cuprizone model. Cuprizone induced demyelination in the corpus callosum and remyelination occurred after cuprizone treatment ceased. This remyelination was inhibited by the administration of DAB. To further examine whether lactate affects proliferation or differentiation of OPCs, we cultured mouse primary OPC-rich cells and analyzed the effect of lactate. Lactate rescued the slowed cell cycling induced by 0.4 mM glucose, as assessed by the BrdU-positive cell ratio. Lactate also promoted OPC differentiation detected by monitoring the mature oligodendrocyte marker myelin basic protein, in the presence of both 36.6 mM and 0.4 mM glucose. Furthermore, these lactate-mediated effects were suppressed by the reported monocarboxylate transporter inhibitor, α-cyano-4-hydroxy-cinnamate. These results suggest that lactate directly promotes the cell cycling rate and differentiation of OPCs, and that glycogen, one of the sources of lactate, contributes to remyelination in vivo. J. Cell. Physiol. 232: 986-995, 2017. © 2016 The Authors. Journal of Cellular Physiology Published by Wiley Periodicals, Inc. © 2016 The Authors. Journal of Cellular Physiology Published by Wiley Periodicals, Inc.

  1. Analysis of Tube Bank Heat Transfer In Downward Directed Foam Flow

    Jonas Gylys


    Full Text Available Apparatus with the foam flow are suitable to use in different technologies like heat exchangers, food industry, chemical and oil processing industry. Statically stable liquid foam until now is used in technologic systems rather seldom. Although a usage of this type of foam as heat transfer agent in foam equipment has a number of advantages in comparison with one phase liquid equipment: small quantity of liquid is required, heat transfer rate is rather high, mass of equipment is much smaller, energy consumption for foam delivery into heat transfer zone is lower. The paper analyzes the peculiarities of heat transfer from distributed in staggered order and perpendicular to foam flow in channel of rectangular cross section tube bundle to the foam flow. It was estimated the dependence of mean gas velocity and volumetric void fraction of foam flow to heat transfer in downward foam flow. Significant difference of heat transfer intensity from front and back tubes of tube row in laminar foam flow was noticed. Dependence of heat transfer on flow velocity and volumetric void fraction of foam was confirmed and estimated by criterion equations.

  2. Experimental Study on the Waste Heat Utilization of Air Compressor in Coal Mine%煤矿空压机废热利用实验研究

    王建学; 牛永胜; 袁静


    针对目前空压机排风废热的回收利用存在的问题,设计了采用热泵技术对空压机废热的回收方案。分析了空压机废热源热泵系统的工作原理,并建立了实验台进行实验研究,测试了不同的空压机排风温度、热水出水温度等因素对空压机废热源热泵系统性能的影响。通过对空压机废热源热泵系统在山西某煤矿的应用的举例,分析了煤矿空压机废热利用可收获的经济效益和社会效益。%Aiming at the current problems for the recycling and utilization of air compressor exhaust waste heat,it designed the recycling plan of air compressor waste heat with heat pump technology.The working principle of the heat pump system of air compressor waste heat source was analyzed,and the experiment table was established to do experimental research,test factors such as different air compressor exhaust temperature,outlet temperature of hot water which influence on the performance of the heat pump system.Through the exemplifying of the air compressor waste heat source heat pump system application to a coal mine in Shanxi province,it analyzed the economic benefit and social benefit which could be obtained by the air compressor waste heat utilization in the coal mine.

  3. Melt dispersion and direct containment heating (DCH) experiments in the DISCO-H test facility

    Meyer, L.; Albrecht, G.; Kirstahler, M.; Schwall, M.; Wachter, E.; Woerner, G.


    (closed pit). The pressure rise in the containment is highest with an open pit and hydrogen combustion. With a closed pit the gas and the debris have to flow first into the subcompartment and then through relatively small cross sections into the containment. Considerable less hydrogen was produced and burned in this case. In the test without steam, no hydrogen effect was present, but, with the direct path to the containment open, a large amount of debris was dispersed into the containment, and efficiently transferred heat to its atmosphere. (orig.)

  4. Heat Transfer Model of Directional Solidification by LMC Process for Superalloy Casting Based on Finite Element Method

    Cao, Liu; Liao, Dunming; Lu, Yuzhang; Chen, Tao


    With the rapid development of the aviation industry, the turbine blade, a critical component of the aeronautical engine, has come to be widely produced by liquid-metal cooling (LMC) process. A temperature- and time-dependent heat transfer coefficient was used to represent the heat convection between the shell and the cooling liquid, and an improved Monte Carlo ray-tracing approach was adopted to handle the boundary of radiation heat transfer. Unstructured mesh was used to fit the irregular shell boundary, and the heat transfer model of directional solidification by LMC process based on finite element method (FEM) was established. The concept of local matrix was here proposed to guarantee computational efficiency. The pouring experiments of directional solidification by LMC process were carried out, then simulation and experimental results were compared here. The accuracy of the heat transfer model was validated by the cooling curves and grain morphology, and the maximum relative error between simulation and experimental cooling curve was 2 pct. The withdrawal rate showed an important influence on the shape of solidification interface, and stray grain is liable to be generated on the bottom of platform at an excessive withdrawal rate.

  5. Estimation of Heat Transfer Coefficients for Biomass Particles by Direct Numerical Simulation Using Microstructured Particle Models in the Laminar Regime

    Pecha, M. Brennan; Garcia-Perez, Manuel; Foust, Thomas D.; Ciesielski, Peter N.


    Direct numerical simulation of convective heat transfer from hot gas to isolated biomass particle models with realistic morphology and explicit microstructure was performed over a range of conditions with laminar flow of hot gas (500 degrees C). Steady-state results demonstrated that convective interfacial heat transfer is dependent on the wood species. The computed heat transfer coefficients were shown to vary between the pine and aspen models by nearly 20%. These differences are attributed to the species-specific variations in the exterior surface morphology of the biomass particles. We also quantify variations in heat transfer experienced by the particle when positioned in different orientations with respect to the direction of fluid flow. These results are compared to previously reported heat transfer coefficient correlations in the range of 0.1 < Pr < 1.5 and 10 < Re < 500. Comparison of these simulation results to correlations commonly used in the literature (Gunn, Ranz-Marshall, and Bird-Stewart-Lightfoot) shows that the Ranz-Marshall (sphere) correlation gave the closest h values to our steady-state simulations for both wood species, though no existing correlation was within 20% of both species at all conditions studied. In general, this work exemplifies the fact that all biomass feedstocks are not created equal, and that their species-specific characteristics must be appreciated in order to facilitate accurate simulations of conversion processes.

  6. 工业过程余热回收利用技术研究进展%Review of Waste Heat Utilization Technologies for Industry Processes

    冯惠生; 徐菲菲; 刘叶凤; 单纯


    This paper reviewed the characteristics and applications of waste heat recovery technologies such as heat transfer utilization, refrigeration and heat pump, power generation by organic Rankine cycle (ORC) system and Kalina cycle. The thermodynamic principle and research method existing in the recovery of waste heats were carried out. The dissemination of ORC system and Kalina cycle system are necessary for increasing the effective of waste heat utilization. Meanwhile, refrigeration and heat pump technologies should be combined with specific industry process, application of simulation to the design also should be enhanced.%概述了余热利用的热交换技术、余热制冷制热技术、低温有机朗肯循环及Kaliana循环余热发电技术的应用,并对其热力学原理以及研究方法进行了分析.认为研究推广低温有机朗肯循环及Kalina循环等低温余热发电技术对提高余热利用率更加有效,余热制冷制热技术的应用必须与工艺过程相结合,加强计算机模拟在制冷过程的设计中的应用.

  7. Direct utilization of waste water algal biomass for ethanol production by cellulolytic Clostridium phytofermentans DSM1183.

    Fathima, Anwar Aliya; Sanitha, Mary; Kumar, Thangarathinam; Iyappan, Sellamuthu; Ramya, Mohandass


    Direct bioconversion of waste water algal biomass into ethanol using Clostridium phytofermentans DSM1183 was demonstrated in this study. Fermentation of 2% (w/v) autoclaved algal biomass produced ethanol concentration of 0.52 g L(-1) (solvent yield of 0.19 g/g) where as fermentation of acid pretreated algal biomass (2%, w/v) produced ethanol concentration of 4.6 g L(-1) in GS2 media (solvent yield of 0.26 g/g). The control experiment with 2% (w/v) glucose in GS2 media produced ethanol concentration of 2.8 g L(-1) (solvent yield of 0.25 g/g). The microalgal strains from waste water algal biomass were identified as Chlamydomonas dorsoventralis, Graesiella emersonii, Coelastrum proboscideum, Scenedesmus obliquus, Micractinium sp., Desmodesmus sp., and Chlorella sp., based on ITS-2 molecular marker. The presence of glucose, galactose, xylose and rhamnose were detected by high performance liquid chromatography in the algal biomass. Scanning Electron Microscopy observations of fermentation samples showed characteristic morphological changes in algal cells and bioaccessibility of C. phytofermentans.

  8. Improving MIMO-OFDM decision-directed channel estimation by utilizing error-correcting codes

    P. Beinschob


    Full Text Available In this paper a decision-directed Multiple-Input Multiple-Output (MIMO channel tracking algorithm is enhanced to raise the channel estimate accuracy. While DDCE is prone to error propagation the enhancement employs channel decoding in the tracking process. Therefore, a quantized block of symbols is checked on consistency via the channel decoder, possibly corrected and then used. This yields a more robust tracking of the channel in terms of bit error rate and improves the channel estimate under certain conditions.

    Equalization is performed to prove the feasibility of the obtained channel estimate. Therefore a combined signal consisting of data and pilot symbols is sent. Adaptive filters are applied to exploit correlations in time, frequency and spatial domain. By using good error-correcting coding schemes like Turbo Codes or Low Density Parity Check (LDPC codes, adequate channel estimates can be acquired even at low signal to noise ratios (SNR. The proposed algorithm among two others is applied for channel estimation and equalization and results are compared.

  9. Fast wave direct electron heating in advanced inductive and ITER baseline scenario discharges in DIII-D

    Pinsker, R. I.; Jackson, G. L.; Luce, T. C.; Politzer, P. A. [General Atomics, PO Box 85608, San Diego, California 92186-5608 (United States); Austin, M. E. [University of Texas at Austin, Austin, Texas 78712 (United States); Diem, S. J.; Kaufman, M. C.; Ryan, P. M. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Doyle, E. J.; Zeng, L. [University of California Los Angeles, Los Angeles, California 90095 (United States); Grierson, B. A.; Hosea, J. C.; Nagy, A.; Perkins, R.; Solomon, W. M.; Taylor, G. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Maggiora, R.; Milanesio, D. [Politecnico di Torino, Dipartimento di Elettronica, Torino (Italy); Porkolab, M. [Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Turco, F. [Columbia University, New York, New York 10027 (United States)


    Fast Wave (FW) heating and electron cyclotron heating (ECH) are used in the DIII-D tokamak to study plasmas with low applied torque and dominant electron heating characteristic of burning plasmas. FW heating via direct electron damping has reached the 2.5 MW level in high performance ELMy H-mode plasmas. In Advanced Inductive (AI) plasmas, core FW heating was found to be comparable to that of ECH, consistent with the excellent first-pass absorption of FWs predicted by ray-tracing models at high electron beta. FW heating at the ∼2 MW level to ELMy H-mode discharges in the ITER Baseline Scenario (IBS) showed unexpectedly strong absorption of FW power by injected neutral beam (NB) ions, indicated by significant enhancement of the D-D neutron rate, while the intended absorption on core electrons appeared rather weak. The AI and IBS discharges are compared in an effort to identify the causes of the different response to FWs.


    Lucia, Lucian A


    Purpose: The purpose of the project was to retrofit the front end (pulp house) of a commercial kraft pulping mill to accommodate a mill green liquor (GL) impregna-tion/soak/exposure and accrue downstream physical and chemical benefits while prin-cipally reducing the energy footprint of the mill. A major player in the mill contrib-uting to excessive energy costs is the lime kiln. The project was intended to offload the energy (oil or natural gas) demands of the kiln by by-passing the causticization/slaking site in the recovery area and directly using green liquor as a pulping medium for wood. Scope: The project was run in two distinct, yet mutually compatible, phases: Phase 1 was the pre-commercial or laboratory phase in which NC State University and the Insti-tute of Paper Science and Technology (at the Georgia Institute of Technology) ran the pulping and associated experiments, while Phase 2 was the mill scale trial. The first tri-al was run at the now defunct Evergreen Pulp Mill in Samoa, CA and lead to a partial retrofit of the mill that was not completed because it went bankrupt and the work was no longer the low-hanging fruit on the tree for the new management. The second trial was run at the MeadWestvaco Pulp Mill in Evedale, TX which for all intents and pur-poses was a success. They were able to fully retrofit the mill, ran the trial, studied the pulp properties, and gave us conclusions.

  11. Utilization of a cell separation technique to evaluate patients with a positive direct antiglobulin test.

    Wallas, C H; Tanley, P C; Gorrell, L P


    Density distribution curves of red blood cells (RBC) from patients with a positive direct antiglobulin test (DAT) were compared to a standardized curve constructed from cell column measurements of centrifuged microcapillary tubes filled with RBC and phthalate ester mixtures encompassing a specific gravity range of 1.078 to 1.114. Shortened survival resulted in a loss of older RBC and a shift of the curve to the right over the high specific gravity ester range. Reticulocytosis resulted in a downward shift of the curve over the low specific gravity range. In patients with a positive DAT due to an autoantibody or drug, the density distribution curve was either normal or demonstrated evidence of shortened RBC survival. In patients with a positive DAT due to an alloantibody, however, evidence of shortened survival was not seen. The distribution of antibody on young and old RBC harvested from the appropriate microcapillary tubes depended upon the etiology of that antibody. In patients with a positive DAT due to to an alloantibody or drug, both the young and old RBC gave an equally reactive DAT, while in patients with a positive DAT due to an alloantibody the young cells were weakly reactive or nonreactive and the older cells were more strongly reactive. When used together, the position of the density distribution curve and the pattern of distribution of antibody coating on young and old RBC provide important diagnostic information about the etiology and clinical status in a patient with a positive DAT and allow for the recognition of an alloantibody and autoantibody when both are present in the same patient.

  12. Utilizing ras signaling pathway to direct selective replication of herpes simplex virus-1.

    Weihong Pan

    Full Text Available Re-engineering the tropism of viruses is an attractive translational strategy for targeting cancer cells. The Ras signal transduction pathway is a central hub for a variety of pro-oncogenic events with a fundamental role in normal and neoplastic physiology. In this work we were interested in linking Ras activation to HSV-1 replication in a direct manner in order to generate a novel oncolytic herpes virus which can target cancer cells. To establish such link, we developed a mutant HSV-1 in which the expression of ICP4 (infected cell protein-4, a viral protein necessary for replication is controlled by activation of ELK, a transcription factor down-stream of the Ras pathway and mainly activated by ERK (extracellular signal-regulated kinase, an important Ras effector pathway. This mutant HSV-1 was named as Signal-Smart 1 (SS1. A series of prostate cells were infected with the SS1 virus. Cells with elevated levels of ELK activation were preferentially infected by the SS1 virus, as demonstrated by increased levels of viral progeny, herpetic glycoprotein C and overall SS1 viral protein production. Upon exposure to SS1, the proliferation, invasiveness and colony formation capabilities of prostate cancer cells with increased ELK activation were significantly decreased (p<0.05, while the rate of apoptosis/necrosis in these cells was increased. Additionally, high Ras signaling cells infected with SS1 showed a prominent arrest in the G1 phase of the cell cycle as compared to cells exposed to parental HSV-1. The results of this study reveal the potential for re-modeling the host-herpes interaction to specifically interfere with the life of cancer cells with increased Ras signaling. SS1 also serves as a "prototype" for development of a family of signal-smart viruses which can target cancer cells on the basis of their signaling portfolio.

  13. Toxicological evaluation of liquids proposed for use in direct contact liquid--liquid heat exchangers for solar heated and cooled buildings

    Buchan, R.M.; Majestic, J.R.; Billau, R.


    This report contains the results of the toxicological evaluation part of the project entitled, ''Direct Contact Liquid-Liquid Heat Exchangers for Solar Heated and Cooled Buildings.'' Obviously any liquid otherwise suitable for use in such a device should be subjected to a toxicological evaluation. 34 liquids (24 denser than water, 10 less dense) have physical and chemical properties that would make them suitable for use in such a device. In addition to the complexity involved in selecting the most promising liquids from the standpoint of their chemical and physical properties is added the additional difficulty of also considering their toxicological properties. Some of the physical and chemical properties of these liquids are listed. The liquids are listed in alphabetical order within groups, the denser than water liquids are listed first followed by those liquids less dense than water.

  14. 渔船动力余热制冷技术%Refrigeration Technology Utilizing Engine Waste Heat in Fishing Vessels

    陈少杰; 陈光明


    Ice and compression refrigeration are normally used to preserve caught fish on fishing vessels.At the same time, waste heat dissipated in hot exhaust gas on fishing vessels is rejected to the atmosphere.Utilizing the vast amount of the waste energy for refrigeration is both economical and energy saving.Three kinds of heat driven refrigeration cycles as adsorption, absorption and ejection are introduced in this paper.Advantages and disadvantages of the three cycles are analyzed based on the working condition of ice making on fishing ves_sels.Emphases have been made on the feasibility of transforming the existing compression refrigeration cycle on fishing vessels by ejection technology.The result shows that 54.5﹪ of fuel for refrigeration system can be saved after combining ejection and compression cycle and the transforming cost can be recovered in 1 year.%渔船通常需要带冰或使用压缩式制冷来满足渔获冷藏保鲜的需要,而渔船发动机尾气中有大量的热能被排放到环境中去,利用渔船发动机尾气余热制冷是一种既经济又节能的好方法。本文介绍了吸附式﹑吸收式和喷射式三种热能驱动的制冷循环,并针对渔船制冰工况对这三种循环在渔船中应用的优缺点进行了分析;重点讨论了使用喷射式制冷技术对渔船现有压缩式制冷系统进行改造的可行性。研究结果表明,将喷射制冷与压缩制冷结合,可减少渔船制冷系统燃料消耗54.5﹪,在1年内即可收回改造成本。

  15. Application of Quasi-Heat-Pulse Solutions for Luikov’s Equations of Heat and Moisture Transfer for Calibrating and Utilizing Thermal Properties Apparatus

    Mark A. Dietenberger; Charles R. Boardman


    Several years ago the Laplace transform solutions of Luikov’s differential equations were presented for one-dimensional heat and moisture transfer in porous hydroscopic orthotropic materials for the boundary condition of a gradual heat pulse applied to both surfaces of a flat slab. This paper presents calibration methods and data for the K-tester 637 (Lasercomp),...

  16. Direct heat applications of geothermal energy in The Geysers/Clear Lake region. Volume I. Geotechnical assessment, agribusiness applications, socioeconomic assessment, engineering assessment. Final report


    Discussion is presented under the following section headings: background and some technical characteristics of geothermal resources; geology and geohydrology, geophysics, and, conclusions regarding availability of geothermal energy for nonelectric uses; agricultural assessment of Lake County, site assessment for potential agricultural development, analysis of potential agricultural applications, special application of low cost geothermal energy to algae harvesting, development of an integrated agribusiness, geothermal complex in Lake County, analysis of individual enterprises, and, recommendations for subsequent work; demographic characteristics, economic condition and perspective of Lake County, economic impact of geothermal in Lake County, social and economic factors related to geothermal resource development, socioeconomic impact of nonelectric uses of geothermal energy, and, identification of direct heat applications of geothermal energy for Lake County based on selected interviews; cost estimate procedure, example, justification of procedure, and, typical costs and conclusions; and, recommended prefeasibility and feasibility studies related to construction of facilities for nonelectric applications of geothermal resource utilization. (JGB)

  17. Utilization of remote sensing data on meteorological and vegetation characteristics for modeling water and heat regimes of large agricultural region

    Muzylev, Eugene; Startseva, Zoya; Uspensky, Alexander; Volkova, Elena


    season resulted from the model calculation in both above variants having been 20% the discrepancy between corresponding modeled values of W for the same period has not exceeded 8% and the discrepancy between values of E has been within 15%. Such discrepancies are within the limits of the standard W and Ev estimation errors. The final results of the SVAT model calculation utilizing satellite data are the fields of soil water content W, evapotranspiration Ev, vertical water and heat fluxes, land surface temperatures and other water and heat regime characteristics area-distributed over the territory of interest in their dynamics for the year 2011-2014 vegetation seasons. Discrepancies between Ev and W calculation results and observation data (~ 20-25 and 10-15%) have not exceeded the standard error of their estimation which corresponds to the adopted accuracy criteria of such estimates.

  18. The effect of direction for hydrophobic lines on subcooled flow boiling: Critical heat flux and heat transfer coefficient

    Kim, Jin Man; Yu, Dong In; Park, Hyun Sun; Kim, Moo Hwan [POSTECH, Pohang (Korea, Republic of)


    A lot of time and effort were dedicated on study of BHT and CHF to understand and control boiling characteristics. To enhance boiling performance, structure and coating have been focused on recently. Coating can change wettability of the surface by controlling surface energy. Structure can affect nucleation cavity or wettability. These techniques make differences for boiling phenomena. From many reports, structures have received much attention due to facileness of manipulation for wetting, and so much data were collected about structures and boiling characteristics. In comparison to the structure, the study of coating technique is less active. Hydrophilic surface without structure is difficult to make for lasting during boiling condition, and hydrophobic surface impoverish CHF due to early dryout. For this reason, the study of coating effect is deficient relatively. However, hydrophobic pattern can be a brilliant method to enhance boiling performance. Betz et al. manufactured superbiphilic surfaces having juxtaposing hexagonal hydrophobic dots on the superhydrophilic surface. This surface improved HTC up to three times higher than on reported nanostructured surfaces. They reported that results were from increasing nucleation site due to hydrophobicity and constraining of bubble expansion on the surface to prevent formation of vapor blanket. In this study, hydrophobic patterns with stripe lines were achieved to study direction effect of hydrophobic pattern using Teflon solution, and further research is suggested. From the analysis of bubble dynamics with pattern effects, the following conclusions can be summarized. 1. Teflon coating can make many bubbles at early stage, so it showed the highest HTC, but lowest CHF due to early formation of vapor blanket. 2. Parallel patterns are advantageous higher CHF due to segregated vapor path in flow direction. 3. Cross patterns are unfavorable to delay CHF because merged vapor jets could cover hydrophilic line.

  19. Direct Numerical Simulation of Transitional and Turbulent Flow Over a Heated Flat Plate Using Finite-Difference Schemes

    Madavan, Nateri K.


    The work in this report was conducted at NASA Ames Research Center during the period from August 1993 to January 1995 deals with the direct numerical simulation of transitional and turbulent flow at low Mach numbers using high-order-accurate finite-difference techniques. A computation of transition to turbulence of the spatially-evolving boundary layer on a heated flat plate in the presence of relatively high freestream turbulence was performed. The geometry and flow conditions were chosen to match earlier experiments. The development of the momentum and thermal boundary layers was documented. Velocity and temperature profiles, as well as distributions of skin friction, surface heat transfer rate, Reynolds shear stress, and turbulent heat flux were shown to compare well with experiment. The numerical method used here can be applied to complex geometries in a straightforward manner.

  20. Effect of solar irradiation on forced convective heat transfer through a nanofluid based direct absorption solar collector

    Parvin, Salma; Ahmed, Sajid; Chowdhury, Raju


    The present work investigates numerically the convective and radiative heat transfer performance and entropy generation of forced convection through a direct absorption solar collector (DASC). Four different fluids; Cu-water nanofluid, Al2O3-waternanofluid, TiO2-water nanofluid and pure water are used as the working fluid. Entropy production has been taken into account in addition to the collector efficiency and heat transfer enhancement. Penalty finite element method with Galerkin's weighted residual technique is used to solve the governing non-linear partial differential equations. Numerical simulations are performed for the variation of solar irradiation (I). The outcomes are presented in the form of isotherms, average output temperature, the average Nusselt number, collector efficiency, average entropy generation and Bejan number. The results present that the rate of heat transfer and collector efficiency enhance significantly for raising the values of I upto a certain range.

  1. Integration of Heat Treatment with Shot Peening of 17-4 Stainless Steel Fabricated by Direct Metal Laser Sintering

    AlMangour, Bandar; Yang, Jenn-Ming


    Direct metal laser sintering (DMLS) is a promising powder-based additive manufacturing process for fabrication of near-net-shape parts. However, the typically poor fatigue performance of DMLS parts must be addressed for use in demanding industrial applications. Post-treatment can be applied to enhance the performance of such components. Earlier attempts at inducing grain refinement through severe plastic deformation of part surfaces using shot peening improved the physical and mechanical properties of metals without chemical alteration. However, heat treatment can modify the surface-hardening effects attained by shot peening. Hence, we examined the feasibility of applying shot peening combined with heat treatment to improve the performance of DMLS-fabricated 17-4 stainless steel parts through microstructural evolution studies and hardness measurements. Compared to a specimen treated only by shot peening, the sample exposed to additional heat treatment showed increased hardness due to aging of the dominant phase.

  2. 焦化冷却水低品质余热的回收利用%Practice of Recycling and Utilization of Low Quality Waste Heat of Cooling Water in Coking Process

    刘亮; 张顺贤


    TImprovement of the recovery and utilization of waste heat in the primary cooler was taken. The new type of steam, hot water dual-use refrigeration and the heating double working conditions of absorption type heat pump unit were developed. The cross flow cooling tower technology, transformation of the original water and water back pipe and other measures were introduced. The purpose of the water temperature process cooling water with low quality of heat and water for heating were realized. So the heating area was expanded, the steam, the new water consumption and dosage of the medicine can be reduced. The single heating season can produce direct benefits 21 260 000 Yuan.%通过对初冷器余热回收利用装置的升级改造,开发新型蒸汽、热水两用型制冷、采暖双工况吸收式热泵机组,引进横流式冷却塔技术,改造原中温水回水工艺管道等措施,实现了辅以蒸汽为热源回收中温工艺冷却水低品质余热来加热采暖水的目的,扩大了采暖供热面积,降低了系统蒸汽、新水消耗和药剂投加量,单个采暖季可产生直接效益2126万元。

  3. Study and testing of direct contact heat exchangers for geothermal brines. Final report, June 1975--July 1976

    Suratt, W.B.; Hart, G.K.


    The object of the work reported herein was to assess the technical and economic feasibility of preheating and evaporating a secondary fluid via direct contact with hot geothermal brine. The work covered a period of 12 months and included the design, construction, and testing of a unit which heats and vaporizes 10 gpm of isobutane by direct contact with 325/sup 0/F brine. The analytical and experimental efforts explored design and economic characteristics, including anticipated problem areas such as working fluid loss in the brine, production of a stable dispersion of the working fluid in brine, fluids separation, axial mixing and carry-over of water vapor with the working fluid. Isobutane was selected as the working fluid for tests primarily because of the favorable amount of net work produced per pound of geothermal brine and the low amount and cost of working fluid lost in the heat exchange process. The Elgin Spray Tower concept was selected for the preheater and boiler. The test apparatus includes a separate boiler and a separate preheater, each 6'' diameter by 6' high. Brine enters the top of each vessel and leaves the bottom. Isobutane enters the bottom of the preheater through a distributor plate to produce 0.15 inch diameter drops. The experimental unit operated with no major problems and demonstrated its hydraulic and thermal capabilities. Volumetric heat transfer coefficients obtained ranged up to 4000 BTU/hr /sup 0/F ft/sup 3/. Boiling heat transfer coefficients of as high as 17,000 BTU/hr /sup 0/F ft/sup 3/ were obtained with a design value of 10,000 BTU/hr /sup 0/F ft/sup 3/. Amount of isobutane in a 21 percent NaCl solution leaving the preheater was less than 40 ppM. A conceptual design and cost estimate was prepared for a direct contact heat exchange system sized for a 50 MW power plant.

  4. Diode lasers for direct application by utilizing a trepanning optic for remote oscillation welding of aluminum and copper

    Fritsche, Haro; Müller, Norbert; Ferrario, Fabio; Fetissow, Sebastian; Grohe, Andreas; Hagen, Thomas; Steger, Ronny; Katzemaikat, Tristan; Ashkenasi, David; Gries, Wolfgang


    We report the first direct diode laser module integrated with a trepanning optic for remote oscillation welding. The trepanning optic is assembled with a collimated DirectProcess 900 laser engine. This modular laser is based on single emitters and beam combiners to achieve fiber coupled modules with a beam parameter product or BPP design consists in vertically stacking several diodes in the fast axis which leads to a rectangular output of about 100 W with BPP of product of the original vertical stack without the power loss of fiber coupling. The 500 W building blocks feature a highly flexible emitting wavelength bandwidth. New wavelengths can be configured by simply exchanging parts and without modifying the production process. This design principle provides the option to adapt the wavelength configuration to match a broad set of applications, from the UV to the visible and to the far IR depending on the commercial availability of laser diodes. This opens numerous additional applications like laser pumping, scientific and medical applications, as well as materials processing applications such as cutting and welding of copper aluminum or steel. Furthermore, the module's short lead lengths enable very short pulses. Integrated with electronics, the module's pulse width can be adjusted from micro-seconds to cw mode operation by simple software commands. An optical setup can be directly attached instead of a fiber to the laser module thanks to its modular design. This paper's experimental results are based on a trepanning optic attached to the laser module. Alltogether the setup approximately fits in a shoe box and weighs less than 20 kg which allows for direct mounting onto a 3D-gantry system. The oscillating weld performance of the 500 W direct diode laser utilizing a novel trepanning optic is discussed for its application to aluminum/aluminum and aluminum/copper joints.

  5. TamiR159 directed wheat TaGAMYB cleavage and its involvement in anther development and heat response.

    Yu Wang

    Full Text Available In Arabidopsis and rice, miR159-regulated GAMYB-like family transcription factors function in flower development and gibberellin (GA signaling in cereal aleurone cells. In this study, the involvement of miR159 in the regulation of its putative target TaGAMYB and its relationship to wheat development were investigated. First, we demonstrated that cleavage of TaGAMYB1 and TaGAMYB2 was directed by miR159 using 5'-RACE and a transient expression system. Second, we overexpressed TamiR159, TaGAMYB1 and mTaGAMYB1 (impaired in the miR159 binding site in transgenic rice, revealing that the accumulation in rice of mature miR159 derived from the precursor of wheat resulted in delayed heading time and male sterility. In addition, the number of tillers and primary branches in rice overexpressing mTaGAMYB1 increased relative to the wild type. Our previous study reported that TamiR159 was downregulated after two hours of heat stress treatment in wheat (Triticum aestivum L.. Most notably, the TamiR159 overexpression rice lines were more sensitive to heat stress relative to the wild type, indicating that the downregulation of TamiR159 in wheat after heat stress might participate in a heat stress-related signaling pathway, in turn contributing to heat stress tolerance.

  6. Direct waste heat recovery via thermoelectric materials - chosen issues of the thermodynamic description

    Kolasiński, Piotr; Kolasińska, Ewa


    The effective waste heat recovery is one of the present-day challenges in the industry and power engineering. The energy systems dedicated for waste heat conversion into electricity are usually characterized by low efficiency and are complicated in the design. The possibility of waste heat recovery via thermoelectric materials may be an interesting alternative to the currently used technologies. In particular, due to their material characteristics, conducting polymers may be competitive when compared with the power machinery and equipment. These materials can be used in a wide range of the geometries e.g. the bulk products, thin films, pristine form or composites and the others. In this article, the authors present selected issues related to the mathematical and thermodynamic description of the heat transfer processes in the thermoelectric materials dedicated for the waste heat recovery. The link of these models with electrical properties of the material and a material solution based on a conducting polymer have also been presented in this paper.




    Full Text Available The current paper provides a brief summary of the district heating system of the municipality Chisinau, including heat power sources, heat distribution network, production and consumption development over the past two decades and other data. Also, the priority investment projects realized by JSC "Termocom" are being presented. The company had implemented an automated monitoring system for the heat power production, transportation and distribution. For many years, the company used bellows pipes with polyurethane insulation, ball valves and plate heat exchangers. 14 out of 21 district heating boiler stations were upgraded 10 were completely automated having as a result no further need in full-time duty personnel there. The experience gained in the implementation of capacity banks and frequency inverters, summarizing the benefits and achieved results, is also presented in the current paper. It is to be underlined that in 2011 the company achieved decrease in electricity consumption by about 30% in comparison with 2005.

  8. Diagnosing Direct-Drive, Shock-Heated, and Compressed Plastic Planar Foils with Noncollective Spectrally Resolved X-Ray Scattering

    Sawada, H.; Regan, S.P.; Meyerhofer, D.D.; Igumenshchev, I.V.; Goncharov, V.N.; Boehly, T.R.; Epstein, R.; Sangster, T.C.; Smalyuk, V.A.; Yaakobi, B.; Gregori, G.; Glenzer, S.H.; Landen, O.L.


    The electron temperature (Te) and average ionization (Z) of nearly Fermi-degenerate, direct-drive, shock-heated, and compressed plastic planar foils were investigated using noncollective spectrally resolved x-ray scattering on the OMEGA Laser System. Plastic (CH) and Br-doped CH foils were driven with six beams, having an overlapped intensity of ~1 × 10^14 W/cm^2 and generating ~15-Mbar pressure in the foil.

  9. 我国工业余热回收利用技术综述%An Overview of Domestic Technologies for Waste Heat Utilization

    连红奎; 李艳; 束光阳子; 顾春伟


    节能减排主要依靠工业领域,工业余热利用是重要内容.本文从余热利用过程能量转换情况角度,概述了国内用于余热利用的热交换技术、热功转换余热发电技术及余热制冷制热技术及其设备的技术特点及应用概况,分析了工业余热利用中的存在的问题,认为需进一步推广余热锅妒及低温汽轮机余热发电技术,提高中高温余热的利用率,需要强化研究并掌握有机朗肯循环等300℃以下低温余热发电技术,积极向工程应用推广,提高低品位余热利用率.%Waste heat recovery in industry is indispensable in saving energy, lowering energy consumption and reducing pollutants. This paper overviewed the characteristics and applications of waste heat recovery technologies in China such as heat transfer utilization, power generation technologies, refrigeration and heat pump. The dissemination of waste heat boiler and power generation technologies is necessary for increasing the ratio of midium/high temperature waste heat utilization; meanwhile Organic Rankine Cycle system is an effective solution to the low temperature waste heat recovery and the development is a pressing need.

  10. Eddy heat fluxes from direct current measurements of the Antarctic Polar Front in Shag Rocks Passage

    Walkden, GJ; Heywood, Kj; Stevens, DP


    Determining meridional heat flux in the Southern Ocean is critical to the accurate understanding and model simulation of the global ocean. Mesoscale eddies provide a significant but poorly-defined contribution to this transport. An eighteen-month deep-water current meter array deployment in Shag Rocks Passage (53°S, 48°W) between May 2003 and November 2004 provides estimates of the eddy flux of heat across the Polar Front. We calculate a statistically nonzero (99% level), vertically coherent ...

  11. Effect of HF Heating Array Directivity Pattern on the Frequency Response of Generated ELF/VLF.


    hhEEE|hhEE 1H ; 11:j28 111125 . mm 11111 II ll1 111 .8 MICROCOPY RESOLUTION TESI CHART I fJC ’RL_-SCI-475l I( .-cmon Numters: 1.5.1. 3.1.4, 3.2.1,.3.3...the high power HF heating facility at the Arecibo Observatory in Puerto Rico. The pattern was calculated using pattern multi- plication and method of...high power HF heating facility at the Arecibo Observatory in Puerto Rico. The pattern was calculated using pattern multiplication and method of

  12. Elastic Model Transitions: a Hybrid Approach Utilizing Quadratic Inequality Constrained Least Squares (LSQI) and Direct Shape Mapping (DSM)

    Jurenko, Robert J.; Bush, T. Jason; Ottander, John A.


    A method for transitioning linear time invariant (LTI) models in time varying simulation is proposed that utilizes both quadratically constrained least squares (LSQI) and Direct Shape Mapping (DSM) algorithms to determine physical displacements. This approach is applicable to the simulation of the elastic behavior of launch vehicles and other structures that utilize multiple LTI finite element model (FEM) derived mode sets that are propagated throughout time. The time invariant nature of the elastic data for discrete segments of the launch vehicle trajectory presents a problem of how to properly transition between models while preserving motion across the transition. In addition, energy may vary between flex models when using a truncated mode set. The LSQI-DSM algorithm can accommodate significant changes in energy between FEM models and carries elastic motion across FEM model transitions. Compared with previous approaches, the LSQI-DSM algorithm shows improvements ranging from a significant reduction to a complete removal of transients across FEM model transitions as well as maintaining elastic motion from the prior state.

  13. Electricity use and load management in electricity heated one-family houses from customer and utility perspective; Effekten av effekten - Elanvaendning och laststyrning i elvaermda smaahus ur kund- och foeretagsperspektiv

    Sernhed, Kerstin


    Until recently, the increase in electricity demand and peak power demand has been met by expansion of the electricity production. Today, due to the deregulation of the electricity market, the production capacity is decreasing. Therefore, there is a national interest in finding solutions to peak problems also on the demand side. In the studies described here (Study 1 and 2) ten households in electrically heated houses were examined. In 1999 the utility equipped their customers with a remote metering system (CustCom) that has an in-built load control component. In Study 1, the load pattern of ten households was examined by using energy diaries combined with frequent meter readings (every five minutes) of the load demand for heating, hot water service and domestic electricity use. Household members kept energy diaries over a four-day period in January 2004, noting time, activities and the use of household appliances that run on electricity. The analysis showed that the use of heat-producing household appliances, e.g. sauna, washing machine and dryer, appliances used for cooking, dishwasher and extra electric heaters, contribute to the household's highest peaks. Turning on the sauna and at the same time using the shower equates to a peak load of 7-9 kW. This, in addition to the use of electricity for heating and lighting along alongside electricity use for refrigerators and freezers, results in some households reaching their main fuse level (roughly 13,8 kW for a main fuse of 20 A). This means that the domestic use of electricity makes up a considerable part of the highest peak loads in a household, but the highest peaks occur together with the use of electricity for heating and hot water. In the second study, Study 2, the households participated in a load control experiment, in which the utility was able to turn on and switch off the heating and hot water systems remotely, using the CustCom system. Heating and water heaters were switched off for periods of 1

  14. 76 FR 63211 - Energy Efficiency Program: Test Procedures for Residential Water Heaters, Direct Heating...


    ... descriptors (i.e., thermal efficiency and pool heater heating seasonal efficiency), as well as seasonal energy... ``efficiency descriptor,'' EPCA specifies that for pool heaters, the efficiency descriptor shall be ``thermal efficiency.'' (42 U.S.C. 6291(22)(E)) Further, EPCA defines the ``thermal efficiency of pool heaters'' as...

  15. 76 FR 71835 - Energy Conservation Program: Energy Conservation Standards for Direct Heating Equipment


    ... included: (1) The proposed exclusion requirements for gas log sets; (2) the physical and performance... ambiance with a secondary function of warmth, and that gas log sets can be used as a source of emergency warmth in case of power outages, which disable electric heat pumps. (Rasmussen, Public Meeting...

  16. Direct current heating in superconductor-insulator-superconductor tunnel devices for THz mixing applications

    Dieleman, P; Klapwijk, T.M; Kovtonyuk, S.; van de Stadt, H.


    DC heating effects in superconductor-insulator-superconductor (SIS) tunnel junctions are studied by comparing junctions sandwiched between niobium or aluminum layers. With niobium a temperature rise of several Kelvin is observed, which is reduced by an order of magnitude by using aluminum. A simple

  17. Direct reduction of carburized pre-reduced pellets by microwave heating

    胡兵; 黄柱成; 易凌云; 姜涛


    A new iron-making process using carburized pre-reduced iron ore pellets and microwave heating is investigated. The pre-reduced pellets, with a porous structure, and fine particles are carburized homogeneously at 400-650 °C in a CO atmosphere. The carburized carbon not only acts reaction as a reduction agent, but also absorbs microwave in the reduction process. Hence, the carburized pre-reduced pellets can be rapidly reduced by microwave heating. There are three procedures involved in the process, namely, gas-based pre-reduction, low-temperature carburization and deep reduction by microwave heating. Carburized pre-reduced iron ore pellets show a rapid temperature rise that is twice as fast as the results for pre-reduced pellets in the laboratory. This not only improves the efficiency of the microwave heating, but also accelerates the reduction of iron oxides. The temperature of the pre-reduced pellets rises to 1050 °C in 45 min when the carburization rate is 2.02%, and the metallization rate and compressive strength reach 94.24%and 1725 N/pellet, respectively.

  18. Direct impacts of climatic warming on heat stress in endothermic species: seabirds as bioindicators of changing thermoregulatory constraints.

    Oswald, Stephen A; Arnold, Jennifer M


    There is now abundant evidence that contemporary climatic change has indirectly affected a wide-range of species by changing trophic interactions, competition, epidemiology and habitat. However, direct physiological impacts of changing climates are rarely reported for endothermic species, despite being commonly reported for ectotherms. We review the evidence for changing physiological constraints on endothermic vertebrates at high temperatures, integrating theoretical and empirical perspectives on the morphology, physiology and behavior of marine birds. Potential for increasing heat stress exposure depends on changes in multiple environmental variables, not just air temperature, as well as organism-specific morphology, physiology and behavior. Endotherms breeding at high latitudes are vulnerable to the forecast, extensive temperature changes because of the adaptations they possess to minimize heat loss. Low-latitude species will also be challenged as they currently live close to their thermal limits and will likely suffer future water shortages. Small, highly-active species, particularly aerial foragers, are acutely vulnerable as they are least able to dissipate heat at high temperatures. Overall, direct physiological impacts of climatic change appear underrepresented in the published literature, but available data suggest they have much potential to shape behavior, morphology and distribution of endothermic species. Coincidence between future heat stress events and other energetic constraints on endotherms remains largely unexplored but will be key in determining the physiological impacts of climatic change. Multi-scale, biophysical modeling, informed by experiments that quantify thermoregulatory responses of endotherms to heat stress, is an essential precursor to urgently-needed analyses at the population or species level. © 2012 ISZS, Blackwell Publishing and IOZ/CAS.

  19. Design of serially connected ammonia-water hybrid absorption-compression heat pumps for district heating with the utilisation of a geothermal heat source

    Jensen, Jonas Kjær; Ommen, Torben Schmidt; Markussen, Wiebke Brix;


    District heating (DH) can reduce the primary energy consumption in urban areas with significant heat demands. The design of a serially connected ammonia-water hybrid absorption-compression heat pump system was investigated for operation in the Greater Copenhagen DH network in Denmark, in order...... to supply 7.2 MW heat at 85 °C utilizing a geothermal heat source at 73 °C. Both the heat source and heat sink experience a large temperature change over the heat transfer process, of which a significant part may be achieved by direct heat exchange. First a generic study with a simple representation...

  20. Practice of Hot Rolling Heating Furnace Waste Heat Utilization%热轧加热炉余热利用的实践



    According to waste heat recovery theory and combined with practice of hot rolling heating furnace, it introduced high temperature waste heat’s vaporization cooling and exhaust gas recovery technology, medium temperature preheating billet and preheating combustion air technology, and waste heat boiler using low temperature to produce steam technology.%依照余热梯级回收利用原理,结合在热轧加热炉上的具体实践,对高温余热的汽化冷却和乏气回收技术,中温余热预热坯料和预热助燃空气技术,以及通过余热锅炉使低温余热产蒸汽技术逐一进行了阐述。

  1. Discussion on waste heat comprehensive utilization of heat transfer oil and waste gas%导热油-烟气综合余热利用工艺探讨

    姜学仕; 倪军亮; 范孟洲; 郭黎明


    梁式竖窑导热油余热由于热量小、温度低而易被忽视。通过对梁式竖窑热工分析及导热油余热分析,提出了导热油-烟气综合余热利用方案,并对经济效益进行分析。指出导热油烟气综合利用投资省,回报率高,操作简单,节能减排。%With low calories and low temperature,the waste heat of the heat transfer oil in beam shaft kiln was easy to overlook. Based on thermal analysis and waste heat analysis of the heat transfer oil, the article proposed a comprehensive utilization program of the waste heat of heat transfer oil and waste gas,which had the features such as low invest,high return,simple operation,energy saving and emission reduction.

  2. Performance evaluation of a ground-source heat pump system utilizing a flowing well and estimation of suitable areas for its installation in Aizu Basin, Japan

    Shrestha, Gaurav; Uchida, Youhei; Kuronuma, Satoru; Yamaya, Mutsumi; Katsuragi, Masahiko; Kaneko, Shohei; Shibasaki, Naoaki; Yoshioka, Mayumi


    Development of a ground-source heat pump (GSHP) system with higher efficiency, and evaluation of its operating performance, is essential to expand the growth of GSHP systems in Japan. A closed-loop GSHP system was constructed utilizing a flowing (artesian) well as a ground heat exchanger (GHE). The system was demonstrated for space-heating and space-cooling of a room (area 126.7 m2) in an office building. The average coefficient of performance was found to be 4.5 for space-heating and 8.1 for space-cooling. The maximum heat exchange rate was 70.8 W/m for space-heating and 57.6 W/m for space-cooling. From these results, it was determined that a GSHP system with a flowing well as a GHE can result in higher performance. With this kind of highly efficient system, energy saving and cost reduction can be expected. In order to assess appropriate locations for the installation of similar kinds of GSHP systems in Aizu Basin, a suitability map showing the distribution of groundwater up-flowing areas was prepared based on the results of a regional-scale three-dimensional analytical model. Groundwater up-flowing areas are considered to be suitable because the flowing well can be constructed at these areas. Performance evaluation of the GSHP system utilizing the flowing well, in conjunction with the prepared suitability map for its installation, can assist in the promotion of GSHP systems in Japan.

  3. Performance evaluation of a ground-source heat pump system utilizing a flowing well and estimation of suitable areas for its installation in Aizu Basin, Japan

    Shrestha, Gaurav; Uchida, Youhei; Kuronuma, Satoru; Yamaya, Mutsumi; Katsuragi, Masahiko; Kaneko, Shohei; Shibasaki, Naoaki; Yoshioka, Mayumi


    Development of a ground-source heat pump (GSHP) system with higher efficiency, and evaluation of its operating performance, is essential to expand the growth of GSHP systems in Japan. A closed-loop GSHP system was constructed utilizing a flowing (artesian) well as a ground heat exchanger (GHE). The system was demonstrated for space-heating and space-cooling of a room (area 126.7 m2) in an office building. The average coefficient of performance was found to be 4.5 for space-heating and 8.1 for space-cooling. The maximum heat exchange rate was 70.8 W/m for space-heating and 57.6 W/m for space-cooling. From these results, it was determined that a GSHP system with a flowing well as a GHE can result in higher performance. With this kind of highly efficient system, energy saving and cost reduction can be expected. In order to assess appropriate locations for the installation of similar kinds of GSHP systems in Aizu Basin, a suitability map showing the distribution of groundwater up-flowing areas was prepared based on the results of a regional-scale three-dimensional analytical model. Groundwater up-flowing areas are considered to be suitable because the flowing well can be constructed at these areas. Performance evaluation of the GSHP system utilizing the flowing well, in conjunction with the prepared suitability map for its installation, can assist in the promotion of GSHP systems in Japan.

  4. Novel Concept of the Magmatic Heat Extraction

    Labinov, Mark


    Enhanced Geothermal Systems are the primary sources of interest nowadays. The paper presents a novel concept for the extraction of the magmatic heat directly from the magma chamber by utilizing the thermodynamic Retrograde Condensation curve.

  5. Demand Controlled Economizer Cycles: A Direct Digital Control Scheme for Heating, Ventilating, and Air Conditioning Systems,


    includes a heating coil and thermostatic control to maintain the air in this path at an elevated temperature, typically around 80 degrees Farenheit (80 F...1238 Aug 1 1236 1237 52 1074 1126 50 1033 1083 Sep 8 8 5W 862 7T 600 678 75 603 7r Oct 51 400 451 119 204 323 115 207 322 ov 64 123 287 187 71 258

  6. Direct Electricity from Heat: A Solution to Assist Aircraft Power Demands

    Goldsby, Jon C.


    A thermionic device produces an electrical current with the application of a thermal gradient whereby the temperature at one electrode provides enough thermal energy to eject electrons. The system is totally predicated on the thermal gradient and the work function of the electrode collector relative to the emitter electrode. Combined with a standard thermoelectric device high efficiencies may result, capable of providing electrical energy from the waste heat of gas turbine engines.

  7. Particle concentrating and sorting under a rotating electric field by direct optical-liquid heating in a microfluidics chip.

    Chen, Yu-Liang; Jiang, Hong-Ren


    We demonstrate a functional rotating electrothermal technique for rapidly concentrating and sorting a large number of particles on a microchip by the combination of particle dielectrophoresis (DEP) and inward rotating electrothermal (RET) flows. Different kinds of particles can be attracted (positive DEP) to or repelled (negative DEP) from electrode edges, and then the n-DEP responsive particles are further concentrated in the heated region by RET flows. The RET flows arise from the spatial inhomogeneous electric properties of fluid caused by direct infrared laser (1470 nm) heating of solution in a rotating electric field. The direction of the RET flows is radially inward to the heated region with a co-field (the same as the rotating electric field) rotation. Moreover, the velocity of the RET flows is proportional to the laser power and the square of the electric field strength. The RET flows are significant over a frequency range from 200 kHz to 5 MHz. The RET flows are generated by the simultaneous application of the infrared laser and the rotating electric field. Therefore, the location of particle concentrating can be controlled within the rotating electric field depending on the position of the laser spot. This multi-field technique can be operated in salt solutions and at higher frequency without external flow pressure, and thus it can avoid electrokinetic phenomena at low frequency to improve the manipulation accuracy for lab-on-chip applications.

  8. Modeling 3D conjugate heat and mass transfer for turbulent air drying of Chilean papaya in a direct contact dryer

    Lemus-Mondaca, Roberto A.; Vega-Gálvez, Antonio; Zambra, Carlos E.; Moraga, Nelson O.


    A 3D model considering heat and mass transfer for food dehydration inside a direct contact dryer is studied. The k- ɛ model is used to describe turbulent air flow. The samples thermophysical properties as density, specific heat, and thermal conductivity are assumed to vary non-linearly with temperature. FVM, SIMPLE algorithm based on a FORTRAN code are used. Results unsteady velocity, temperature, moisture, kinetic energy and dissipation rate for the air flow are presented, whilst temperature and moisture values for the food also are presented. The validation procedure includes a comparison with experimental and numerical temperature and moisture content results obtained from experimental data, reaching a deviation 7-10 %. In addition, this turbulent k- ɛ model provided a better understanding of the transport phenomenon inside the dryer and sample.

  9. Modeling 3D conjugate heat and mass transfer for turbulent air drying of Chilean papaya in a direct contact dryer

    Lemus-Mondaca, Roberto A.; Vega-Gálvez, Antonio; Zambra, Carlos E.; Moraga, Nelson O.


    A 3D model considering heat and mass transfer for food dehydration inside a direct contact dryer is studied. The k- ɛ model is used to describe turbulent air flow. The samples thermophysical properties as density, specific heat, and thermal conductivity are assumed to vary non-linearly with temperature. FVM, SIMPLE algorithm based on a FORTRAN code are used. Results unsteady velocity, temperature, moisture, kinetic energy and dissipation rate for the air flow are presented, whilst temperature and moisture values for the food also are presented. The validation procedure includes a comparison with experimental and numerical temperature and moisture content results obtained from experimental data, reaching a deviation 7-10 %. In addition, this turbulent k- ɛ model provided a better understanding of the transport phenomenon inside the dryer and sample.

  10. Direct-fed microbes:A tool for improving the utilization of low quality roughages in ruminants

    Mona M Y Elghandour; Abdelfattah Z M Salem; Jose S Martnez Castaeda; Luis M Camacho; Ahmed E Kholif; Juan C Vzquez Chagoyn


    For many years, ruminant nutritionists and microbiologists have been interested in manipulating the microbial ecosystem of the rumen to improve production efifciency of different ruminant species. Removal and restriction of antibiotics sub-therapeutic uses from ruminant diets has ampliifed interest in improving nutrient utilization and animal performance and search for more safe alternatives. Some bacterial and fungal microorganisms as a direct-fed microbial (DFM) can be the most suitable solutions. Microorganisms that are commonly used in DFM for ruminants may be classiifed mainly as lactic acid producing bacteria (LAB), lactic acid utilizing bacteria (LUB), or other microorganism’s species like Lactobacil us, Bi-ifdobacterium, Enterococcus, Streptococcus, Bacil us, Propionibacterium, Megasphaera elsdeni and Prevotel abryanti , in addition to some fungal species of yeast such as Saccharomyces and Aspergil us. A deifnitive mode of action for bacterial or fungal DFM has not been established;although a variety of mechanisms have been suggested. Bacterial DFM potential y moderate rumen conditions, and improve weight gain and feed efifciency. Fungal DFM may reduce harmful oxygen from the rumen, prevent excess lactate production, increase feed digestibility, and alter rumen fermentation patterns. DFM may also compete with and inhibit the growth of pathogens, immune system modulation, and modulate microbial balance in the gastrointestinal tract. Improved dry matter intake, milk yield, fat corrected milk yield and milk fat content were obtained with DFM administration. However, the response to DFM is not constant;depending on dosages, feeding times and frequencies, and strains of DFM. Nonetheless, recent studies have supported the positive effects of DFM on ruminant performance.

  11. Non-Newtonian unconfined flow and heat transfer over a heated cylinder using the direct-forcing immersed boundary-thermal lattice Boltzmann method.

    Amiri Delouei, A; Nazari, M; Kayhani, M H; Succi, S


    In this study, the immersed boundary-thermal lattice Boltzmann method has been used to simulate non-Newtonian fluid flow over a heated circular cylinder. The direct-forcing algorithm has been employed to couple the off-lattice obstacles and on-lattice fluid nodes. To investigate the effect of boundary sharpness, two different diffuse interface schemes are considered to interpolate the velocity and temperature between the boundary and computational grid points. The lattice Boltzmann equation with split-forcing term is applied to consider the effects of the discrete lattice and the body force to the momentum flux, simultaneously. A method for calculating the Nusselt number based on diffuse interface schemes is developed. The rheological and thermal properties of non-Newtonian fluids are investigated under the different power-law indices and Reynolds numbers. The effect of numerical parameters on the accuracy of the proposed method has been investigated in detail. Results show that the rheological and thermal properties of non-Newtonian fluids in the presence of a heated immersed body can be suitably captured using the immersed boundary thermal lattice Boltzmann method.

  12. Further Investigation on Laminar Forced Convection of Nanofluid Flows in a Uniformly Heated Pipe Using Direct Numerical Simulations

    Ghofrane Sekrani


    Full Text Available In the present paper, laminar forced convection nanofluid flows in a uniformly heated horizontal tube were revisited by direct numerical simulations. Single and two-phase models were employed with constant and temperature-dependent properties. Comparisons with experimental data showed that the mixture model performs better than the single-phase model in the all cases studied. Temperature-dependent fluid properties also resulted in a better prediction of the thermal field. Particular attention was paid to the grid arrangement. The two-phase model was used then confidently to investigate the influence of the nanoparticle size on the heat and fluid flow with a particular emphasis on the sedimentation process. Four nanoparticle diameters were considered: 10, 42, 100 and 200 nm for both copper-water and alumina/water nanofluids. For the largest diameter d n p = 200 nm, the Cu nanoparticles were more sedimented by around 80%, while the A l 2 O 3 nanoparticles sedimented only by 2 . 5 %. Besides, it was found that increasing the Reynolds number improved the heat transfer rate, while it decreased the friction factor allowing the nanoparticles to stay more dispersed in the base fluid. The effect of nanoparticle type on the heat transfer coefficient was also investigated for six different water-based nanofluids. Results showed that the Cu-water nanofluid achieved the highest heat transfer coefficient, followed by C, A l 2 O 3 , C u O , T i O 2 , and S i O 2 , respectively. All results were presented and discussed for four different values of the concentration in nanoparticles, namely φ = 0 , 0 . 6 % , 1 % and 1 . 6 % . Empirical correlations for the friction coefficient and the average Nusselt number were also provided summarizing all the presented results.

  13. Direct-drive Energetics of laser-Heated Foam Liners for Hohlraums

    Moore, Alastair; Thomas, Cliff; Baker, Kevin; Morton, John; Baumann, Ted; Biener, Monika; Bhandarkar, Suhas; Hinkel, Denise; Jones, Oggie; Meezan, Nathan; Moody, John; Nikroo, Abbas; Rosen, Mordy; Hsing, Warren


    Lining the walls of a high-Z hohlraum cavity with a low-density foam is predicted to mitigate the challenge presented by hohlraum wall expansion. Once heated, wall material quickly fills the cavity and can impede laser beam propagation. To avoid this, ignition hohlraums are typically filled with a gas or irradiated with a short (laser pulse. A gas-fill has the disadvantage that it can cause laser plasma instabilities (LPI), while a short laser pulse limits the design space to reach low-adiabat implosions. Foam-liners offer a potential route to reduce wall motion in a low gas-fill hohlraum with little LPI. Results from quasi 1-D experiments performed at the NIF are presented These characterize the x-ray conversion efficiency, backscattered laser energy and heat propagation in a 250 μm thick Ta2O5 or ZnO foam-liners spanning a range of densities from underdense to overdense, when irradiated at up to 4.9 x 1014 W/cm2 is incident on a planar foam sample, backed by a Au foil and generates a radiation temperature of up to 240eV - conditions equivalent to a single outer cone beam-spot in an ignition hohlraum. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.

  14. Rapid growth of ZnO hexagonal prism crystals by direct microwave heating

    ZHU Zhenqi; ZHOU Jian; LIU Guizhen; REN Zhiguo


    ZnO hexagonal prism crystals were synthesized from ZnO powders by microwave heating in a short time (within 20 min) without any metal catalyst or transport agent.Zinc oxide raw materials were made by evaporating from the high-temperature zone in an enclosure atmosphere and crystals were grown on the self-source substrate.The inherent asymmetry in microwave heating provides the temperature gradient for crystal growth.Substrate and temperature distribution in the oven show significant effects on the growth of the ZnO crystal.The morphologies demonstrate that these samples are pure hexagonal prism crystals with maximum 80 μm in diameter and 600 μm in length,which possess a well faceted end and side surface.X-ray diffraction (XRD) reveals that these samples are pure crystals.The photoluminescence (PL) exhibits strong ultraviolet emission at room temperature,indicating potential applications for short-wave light-emitting photonic devices.


    T.Yu. Antonets


    Full Text Available In this paper, experiment for determining the temperature difference between the elements of cable and in the open air is considered. The formation of a three cables laid in a plane with different spacing between adjacent cables. Tests to heat of cables for XLPE-polyethylene are used as a solid dielectric insulation. The line to XLPE-cables in group running horizontally, provided that the cables are of equal diameter and emit equal losses. It is limited to the following: the air flow around the cables may be necessary restricted by proximity to next cables. When single-core cables are installed in parallel the load current may not share equally between the parallel cables. This is because a significant proportion of the impedance of large conductors is due to self reactance and mutual reactance. Hence the spacing and relative location of each cable will have an effect on the current sharing. Calculation for each cable configuration is necessary. Possibility of using for determining the thermal properties of XLPE-cables a sheath applied over the cable surface with coefficient convection heat transfer between cable surface and the air region about it of equal zero. The work is devoted to creation of a method for calculation of the current rating of high-voltage cables in conditions function.

  16. A fermentative approach towards optimizing directed biosynthesis of fumaric acid by Rhizopus oryzae 1526 utilizing apple industry waste biomass.

    Das, Ratul Kumar; Brar, Satinder Kaur; Verma, Mausam


    The present research account deals with the bioproduction of fumaric acid (FA) from apple pomace ultrafiltration sludge (APUS) and apple pomace (AP) through fermentation. The filamentous fungus Rhizopus oryzae 1526 was used as a biocatalyst and its morphological impact on FA production was analysed in detail. For submerged fermentation, 40 g L(-1) of total solids concentration of APUS, pH 6.0, 30 °C, 200 rpm flask shaking speed and 72 h of incubation were found to be optimum for FA production (25.2 ± 1.0 g L(-1), 0.350 g (L(-1) h(-1))). Broth viscosity (cP), residual reducing sugar (g L(-1)) and ethanol (g L(-1)) produced as by-product, were also analysed. Plastic trays were used for solid state fermentation and at optimized level of moisture and incubation period, 52 ± 2.67 g FA per kg dry weight of AP was obtained. Changes in the total phenolic content (mg g(-1) dry weight of AP) were monitored at regular intervals. Utilization of APUS and AP for the directed synthesis of the high-value platform chemical FA by the fungal strain R. oryzae 1526 was an excellent display of fungal physiological and morphological control over a fermentative product.

  17. MRI temperature map reconstruction directly from k-space with compensation for heating-induced geometric distortions

    Gaur, Pooja; Grissom, William A.


    Proton resonance frequency (PRF) change is used to measure tissue heating, but also distorts the image and causes geometric distortions in temperature estimates in the same manner as other chemical shift distortions if left uncompensated. We propose an algorithm that produces PRF temperature maps free of these distortions by fitting a signal model directly to acquired k-space data that accounts for PRF-induced phase both up to and during the readout. We also introduce a faster method compatible with Cartesian data that corrects distortions from image-domain temperature maps. Gel heating experiments show the proposed CS compensation algorithms correct magnitude image artifacts and hotspot distortions. Without CS compensation, thermal dose values are overestimated in spiral data, and are spatially offset in 2DFT and EPI data. Compensating for heat-induced CS distortions improves the accuracy of temperature change and thermal dose measurements, and can have a significant positive impact on clinical and research applications of PRF-shift thermometry.

  18. Heat and mass transfer effects in a direct methanol fuel cell: A 1D model

    Oliveira, V.B.; Falcao, D.S.; Pinto, A.M.F.R. [Centro de Estudos de Fenomenos de Transporte, Departamento de Eng. Quimica, Faculdade de Engenharia da Universidade do Porto, Rua Dr. Roberto Frias, 4200-465 Porto (Portugal); Rangel, C.M. [INETI - Unidade de Electroquimica e Materiais, Paco do Lumiar, 22,1649-038 (Portugal)


    Models are a fundamental tool for the design process of fuel cells and fuel cell systems. In this work, a steady-state, one-dimensional model accounting for coupled heat and mass transfer, along with the electrochemical reactions occurring in the DMFC, is presented. The model output is the temperature profile through the cell and the water balance and methanol crossover between the anode and the cathode. The model predicts the correct trends for the influence of current density and methanol feed concentration on both methanol and water crossover. The model estimates the net water transfer coefficient through the membrane, {alpha}, a very important parameter to describe water management in the DMFC. Suitable operating ranges can be set up for different MEA structures maintaining the crossover of methanol and water within acceptable levels. The model is rapidly implemented and is therefore suitable for inclusion in real-time system level DMFC calculations. (author)

  19. Direct electric field heating and acceleration of electrons in solar flares

    Holman, Gordon D.; Benka, Stephen G.


    We show that the observed properties of solar flare X-ray and microwave emission can be explained through the Joule heating and electric field acceleration of runaway electrons in current channels. The global properties of the flaring region required for this are presented. We have fit a hybrid thermal/nonthermal electron distribution, consisting of hot, isothermal electrons with a nonthermal tail of runaway electrons, to high-resolution hard X-ray and microwave spectra and have obtained excellent fits to both. The hybrid model relaxes the electron number and energy flux requirements for the hard X-ray emission over those of a purely nonthermal model. The model also provides explanations for several previously unexplained aspects of the high-resolution microwave spectra. The fit parameters can be related to physical properties (such as the electric field strength in the current channels) of the acceleration region.

  20. Organic thermoelectric materials: emerging green energy materials converting heat to electricity directly and efficiently.

    Zhang, Qian; Sun, Yimeng; Xu, Wei; Zhu, Daoben


    The abundance of solar thermal energy and the widespread demands for waste heat recovery make thermoelectric generators (TEGs) very attractive in harvesting low-cost energy resources. Meanwhile, thermoelectric refrigeration is promising for local cooling and niche applications. In this context there is currently a growing interest in developing organic thermoelectric materials which are flexible, cost-effective, eco-friendly and potentially energy-efficient. In particular, the past several years have witnessed remarkable progress in organic thermoelectric materials and devices. In this review, thermoelectric properties of conducting polymers and small molecules are summarized, with recent progresses in materials, measurements and devices highlighted. Prospects and suggestions for future research efforts are also presented. The organic thermoelectric materials are emerging candidates for green energy conversion.

  1. Effective utilization of heat from incinerating brewer prime s grains and dehydrated sludge. Beer kasu dassui odei shokyakunetsu no yuko riyo

    Ogawa, T. (Asahi Breweries, Ltd., Tokyo (Japan))


    Merits of treatment cost reduction and effective utilization of waste heat were obtained through effectively utilizing the waste heat from the in-plant incineration of the brewer {prime} s grains (barley grains) generated from the brewing processes, and the dehydrated sludge generated from the waste water treatment. Keeping the pace with increase in the annual manufacturing capacity at Hakata Plant, from 60,000 kl to 180,000 kl, the brewer {prime} s grain generation has increased, but these grains have become unable to be utilized as livestock feed due to the appreciation of the yen value, hence the excess is now disposed of as wastes, causing an expense increase. Therefore, these will be incinerated together with the hydrated sludge. Because dehydrating the grains will produce fluids with high BOD value, the grains are to be burned as they are, and for this reason, a fluidized bed furnace was introduced. Effects of the incineration to the environment were surveyed, and it was confirmed that the parameters agreed with the Fukuoka Municipality can be maintained. The operation was begun in June 1989. As a result of the measures applied, an annual monetary saving of about 100 million yen can be expected out of the capital investment of 350 million yen, with the return of investment estimated to be made in about four years. 21 figs., 9 tabs.

  2. Monte Carlo direct view factor and generalized radiative heat transfer programs

    Mc Williams, J. L.; Scates, J. H.


    Computer programs find the direct view factor from one surface segment to another using the Monte carlo technique, and the radioactive-transfer coefficients between surface segments. An advantage of the programs is the great generality of problems treatable and rapidity of solution from problem conception to receipt of results.

  3. Effect of -based Direct-fed Microbial on Performance, Nutrient Utilization, Intestinal Morphology and Cecal Microflora in Broiler Chickens

    Xinjian Lei


    Full Text Available The present study was conducted to evaluate the effect of the dietary supplementation of Bacillus amyloliquefaciens-based direct-fed microbial (DFM on growth performance, nutrient utilization, intestinal morphology and cecal microflora in broiler chickens. A total of two hundred and eighty eight 1-d-old Arbor Acres male broilers were randomly allocated to one of four experimental treatments in a completely randomized design. Each treatment was fed to eight replicate cages, with nine birds per cage. Dietary treatments were composed of an antibiotic-free basal diet (control, and the basal diet supplemented with either 15 mg/kg of virginiamycin as antibiotic growth promoter (AGP, 30 mg/kg of Bacillus amyloliquefaciens-based DFM (DFM 30 or 60 mg/kg of Bacillus amyloliquefaciens-based DFM (DFM 60. Experimental diets were fed in two phases: starter (d 1 to 21 and finisher (d 22 to 42. Growth performance, nutrient utilization, morphological parameters of the small intestine and cecal microbial populations were measured at the end of the starter (d 21 and finisher (d 42 phases. During the starter phase, DFM and virginiamycin supplementation improved the feed conversion ratio (FCR; p<0.01 compared with the control group. For the finisher phase and the overall experiment (d 1 to 42 broilers fed diets with the DFM had better body weight gain (BWG and FCR than that of control (p<0.05. Supplementation of virginiamycin and DFM significantly increased the total tract apparent digestibility of crude protein (CP, dry matter (DM and gross energy during both starter and finisher phases (p<0.05 compared with the control group. On d 21, villus height, crypt depth and villus height to crypt depth ratio of duodenum, jejunum, and ileum were significantly increased for the birds fed with the DFM diets as compared with the control group (p<0.05. The DFM 30, DFM 60, and AGP groups decreased the Escherichia coli population in cecum at d 21 and d 42 compared with control

  4. Integration of space heating and hot water supply in low temperature district heating

    Elmegaard, Brian; Ommen, Torben Schmidt; Markussen, Michael


    is required by the consumer. We study conventional district heating at different temperatures and compare the energy and exergetic efficiency and annual heating cost to solutions that utilize electricity for supplementary heating of domestic hot water in low temperature district heating. This includes direct...... electric heating and three heat pump solutions applying R134a and R744. The results show that conventional solutions at lowest possible temperature have the highest exergetic efficiency of 28% and lowest annual cost of € 690 for a 159 m2 house. The best low temperature system is an R134a heat pump with hot......District heating may supply many consumers efficiently, but the heat loss from the pipes to the ground is a challenge. The heat loss may be lowered by decreasing the network temperatures for which reason low temperature networks are proposed for future district heating. The heating demand...

  5. Heat treatment of whole milk by the direct joule effect--experimental and numerical approaches to fouling mechanisms.

    Fillaudeau, L; Winterton, P; Leuliet, J C; Tissier, J P; Maury, V; Semet, F; Debreyne, P; Berthou, M; Chopard, F


    The development of alternative technologies such as the direct Joule effect to pasteurize and sterilize food products is of great scientific and industrial interest. Our objective was 1) to gain insight into the ability to ensure ultra-high-temperature treatment of milk and 2) to investigate the links among thermal, hydraulic, and electrical phenomena in relation to fouling in a direct Joule effect heater. The ohmic heater [OH; E perpendicular to v (where E is the electrical field and v is the velocity); P (power) = 15 kW] was composed of 5 flat rectangular cells [e (space between the plate and electrode) = 15 mm, w (wall) = 76 mm, and L (length of the plate in plate heat exchanger or electrode) = 246 mm]--3 active cells to ensure heating and 2 (at the extremities) for electrical insulation and the recovery of leakage currents. In the first step, the thermal performance of the OH was investigated vs. the flow regimen [50 Joule effect in the static deposit, the simulation showed how wall overheating would definitively cause fouling to spiral out of control.

  6. Thermodynamic analysis of Direct Urea Solid Oxide Fuel Cell in combined heat and power applications

    Abraham, F.; Dincer, I.


    This paper presents a comprehensive steady state modelling and thermodynamic analysis of Direct Urea Solid Oxide Fuel Cell integrated with Gas Turbine power cycle (DU-SOFC/GT). The use of urea as direct fuel mitigates public health and safety risks associated with the use of hydrogen and ammonia. The integration scheme in this study covers both oxygen ion-conducting solid oxide fuel cells (SOFC-O) and hydrogen proton-conducting solid oxide fuel cells (SOFC-H). Parametric case studies are carried out to investigate the effects of design and operating parameters on the overall performance of the system. The results reveal that the fuel cell exhibited the highest level of exergy destruction among other system components. Furthermore, the SOFC-O based system offers better overall performance than that with the SOFC-H option mainly due to the detrimental reverse water-gas shift reaction at the SOFC anode as well as the unique configuration of the system.

  7. Factors affecting the potential of direct load control for non-generating utilities. Final report. [Distribution and wholesale power supply interaction



    Several alternatives are available for achieving load management, including direct or voluntary control of customer loads, customer or utility energy storage systems for diurnal load shifting, and expanded interconnection and operation of electric power systems. All of these alternatives are available to the fully integrated (generating, transmitting and distributing) electric utility and the analysis of their effects encompasses the power supply and delivery system. However, the costs and benefits of the alternatives to the fully integrated electric utility are perhaps not so obvious. Therefore, by considering a non-generating utility, this analysis focuses upon the distribution system and wholesale power supply interaction as a step toward an analysis including the power supply and delivery system. This report develops an analysis procedure and discusses some of the relevant factors to be consdered in the application of direct load control for a non-generating utility system. The analysis concentrates on the distribution system only to determine the effect of rates and payback as a result of direct load control. Thus, the study is responsive to the specific needs of the non-generating utility. This analysis of direct load control encompasses the determination of those loads amenable to control, the selection of a suitable one-way communications system to rend control and the estimation of expected benefits and costs. The complementary functions to the application of direct load control such as automatic meter reading via the addition of a bi-directional communications system and voltage control are not included in the analysis but are detailed for future consideration.

  8. Direct numerical simulation of fluid-particle mass, momentum, and heat tranfers in reactive systems.

    Hammouti, Abdelkader; Wachs, Anthony


    Many industrial processes like coal combustion, catalytic cracking, gas phase polymerization reactors and more recently biomass gasification and chemical looping involve two-phase reactive flows in which the continuous phase is a fluid and the dispersed phase consists of rigid particles. Improving both the design and the operating conditions of these processes represents a major scientific and industrial challenge in a context of markedly rising energy cost and sustainable development. Thus, it is above all important to better understand the coupling of hydrodynamic, chemical and thermal phenomena in those flows in order to be able to predict them reliably. The aim of our work is to build up a multi-scale modelling approach of reactive particulate flows and at first to focus on the development of a microscopic-scale including heat and mass transfers and chemical reactions for the prediction of particle-laden flows in dense and dilute regimes. A first step is the upgrading and the validation of our numerical tools via analytical solutions or empirical correlations when it is feasible. These couplings are implemented in a massively parallel numerical code that already enable to take a step towards the enhanced design of semi-industrial processes.

  9. Environmental effects of shifts in a regional heating mix through variations in the utilization of solid biofuels.

    Wolf, Christian; Klein, Daniel; Richter, Klaus; Weber-Blaschke, Gabriele


    Solid Biofuels, i.e. wood, play an important role in present and future national and global climate change mitigation policies. Wood energy, while displaying favorable properties for the mitigation of climate change also exhibits several drawbacks, such as potentially high emission of particulate matter. To assess the environmental effects of shifts in the heating mix, emission factors of the comprising energy carriers and the Bavarian heating mix were determined. Through the application of regionalized substitution percentiles the environmental effects caused by shifts in the amount of final energy provided by solid biofuels could be identified. For this purpose, four scenarios, based on political and scientific specifications were assessed. In 2011 a total amount of 663.715 TJ of final energy was used for the provision of heat in Bavaria, with solid biofuels exhibiting the third largest share of 12.6% (83% of renewable heat). Environmental effects were evaluated through life cycle assessments assessing the impact categories of Global Warming (GW), Particulate Matter emissions (PM), Freshwater Eutrophication (ET) and Acidification (AC). Additionally, the non-renewable primary energy consumption (PE) was analyzed. The heating mix in Bavaria (Baseline) causes emissions of 49.6 Mt CO2-eq. * yr(-1)(GW), 14.555 t of PM2.5-eq. * yr(-1) (PM), 873.4 t P-eq. * yr(-1) (ET), and 82.299 kmol H(+) eq. * yr(-1) (AC), for which 721,745 TJ of primary energy were expended. Current policies entail a GHG reduction potential of approximately 1 Mt CO2-eq. * yr(-1) while increasing the amount of energy wood by 15%. The maximum, hypothetical share of solid biofuels of the heating mix cannot surpass 25%, while the climate change mitigation performance of the current use of solid biofuels is approximately 6.4 Mt CO2-eq. * yr(-1). GHG-emissions would be 13% higher and PM emissions 77% lower without this energetic use of wood. Furthermore, our calculations allow for new specified

  10. The Heat Exchanger Performance of Shell and Multi Tube Helical Coil as a Heater through the Utilization of a Diesel Machine’s Exhaust Gas

    . Zainuddin


    Full Text Available A review on reutilization of heat waste from a diesel machine is absolutely important. This is because the exhaust gas potential of a Diesel machine keeps increasing and not much has been utilized by the industry. One of the techniques of reutilizing the heat waste in industry is by using a heat exchanger. The technique is also very useful for the environment because it can reduce air pollution caused by the exhaust gas of the diesel machine. The main purpose of the research is to find out the capability of shell and multi-tube helical coil HE as an air heater by utilizing the exhaust gas of the Diesel machine. The heat exchanger of shell and multi-tube helical coil  utilizes the exhaust thermal gas of the Diesel machine as the air heater already made. The apparatus has the following dimension: the shell length of 1.05 m, diameter 0.1524 m, tube length of 3.25 m with 20 coils, tube diameter of 0.011 m, coil diameter of 0.0508 m with 4 helical coils. The type of Diesel machine to use in the testing is 4FB1 Isuzu Diesel engine. The machine has the maximum machine power and rotation of 54 kW and 3,600 rpm. The performance testing of heat exchanger has been conducted in some variations of Diesel machine rotations of 1,500 rpm, 1,750 rpm, 2,000 rpm, 2,250 rpm and 2,500 rpm. The testing result shows a maximum effectiveness to happen at the machine rotation of 1,500 rpm. The maximum effectiveness to get is 67.8% and then it goes down drastically in accordance with the increase of air mass flow rate. The hot air temperature created is from 47.1°C to 52.3°C so that it can be used for the purpose of drying up the unhulled rice.

  11. Study of a hydrocarbon-utilizing and emulsifier-producing Acinetobacter calcoaceticus strain isolated from heating oil.

    Marín, M M; Pedregosa, A M; Ortiz, M L; Laborda, F


    Twenty bacterial strains were isolated from a sample of contaminated heating oil and screened for their ability to use petroleum and several common fuels as the sole source of carbon and energy. One of the isolates, named MM5, was able to grow on petroleum derivatives and brought about an emulsification of those compounds. Gas chromatography studies showed that strain MM5 was able to degrade hydrocarbons of heating oil. MM5 has been tentatively identified as a strain of Acinetobacter calcoaceticus. The fine structure of MM5 was examined by transmission electron microscopy. Incubation in the presence of hydrocarbon substrates resulted in the development of intracellular electron-transparent inclusions. These structures were absent in the non-hydrocarbon cultures studied.

  12. 气化工艺黑水闪蒸换热方案研究%Study on the Direct Heat Exchange of Gasification Blackwater Flash Program

    张劲松; 郭伟; 徐才福; 赵涛; 王光友


    The heat recovery process is divided into indirect heat transfer process and direct heat exchange process. The flash process in traditional coal water slurry gasification process is indirect heat exchange process, the emergence of scaling phenomenon causes the heat transfer efficiency drop, which can seriously affect the long term operation of the plant, so the direct contact heat transfer process between ash water and flash gas has been paid much attention. Two schemes of direct heat exchange and indirect heat transfer were compared from the aspects of water consumption, equipment configuration and effect.%按照热量回收的流程划分,分为间接换热流程和直接换热流程。传统的水煤浆加压气化的闪蒸流程即为间接换热流程,由于出现结垢等现象导致换热效率下降,严重时会影响装置的长周期运行,因此采用灰水和闪蒸气直接接触换热的流程逐渐受到各方的重视。对直接换热和间接换热的两种方案,从水耗、设备配置和效果方面进行对比研究。

  13. Energy and economic analysis of total energy systems for residential and commercial buildings. [utilizing waste heat recovery techniques

    Maag, W. L.; Bollenbacher, G.


    Energy and economic analyses were performed for an on-site power-plant with waste heat recovery. The results show that for any specific application there is a characteristic power conversion efficiency that minimizes fuel consumption, and that efficiencies greater than this do not significantly improve fuel consumption. This type of powerplant appears to be a reasonably attractive investment if higher fuel costs continue.

  14. Feedback control for distributed heat transfer mechanisms in direct-contact membrane distillation system

    Eleiwi, Fadi


    In this paper, the problem of stabilization and production rate reference tracking for a Direct-Contact Membrane Distillation (DCMD) system is addressed. Sufficient conditions for the asymptotic and exponential stabilization for DCMD system are presented using the Gronwall-Bellman lemma and Linear Matrix Inequalities (LMIs) approaches, respectively. A nonlinear observer is then proposed to estimate the temperature distribution among the DCMD domain. This contributes to propose a reference production rate control design for the DCMD process via observer-based output control approach. Finally, numerical simulations are given to show the effectiveness of the proposed methods.

  15. Aerosol Climatology at Pune, Western India: Implications to Direct Radiative Forcing and Heating Rates

    Pandithurai, G.; Pinker, R. T.; Devara, P. C.; Raj, P. E.; Jayarao, Y.; Dani, K. K.; Maheskumar, R. S.; Sonbawne, S. M.; Saha, S. K.; Bhawar, R.; Shinde, U. P.


    Extensive aerosol observations were carried out at Indian Institute of Tropical Meteorology (IITM), Pune, an urban site in the western part of the country, using a Prede (Model POM-01L) sun/sky radiometer and a bi-static Argon ion lidar since December 2000 and October 1986, respectively. The sun/sky radiometer was operated daily at every 15 minute interval during day-time to derive column aerosol optical parameters such as aerosol optical depth (AOD), single scattering albedo (SSA), asymmetry parameter (ASY) while the lidar was operated weekly in the early-night period to derive vertical distributions of aerosol number density. The sun/sky radiance data collected during the above period have been analysed by using the radiative transfer model SkyRadPack version 3.0 (Nakajima et al. 1996) to retrieve AOD, SSA and ASY. AOD and SSA retrieved at 15-minutes interval were averaged to get monthly means. On every year from 2000 to 2005, monthly means of AOD show gradual increase of aerosol loading from December to April and Angstrom exponent decreases from March due to local as well as transported dust from African / Arabian regions through Arabian Sea. Monthly means of SSA show decrease from December to April and the wavelength dependence also indicate the abundance of dust from March to May. Lidar-derived vertical distributions yield minimum during the monsoon months, gradually builds up during the post-monsoon and winter months, and finally peaks during the pre-monsoon months in every year (Devara et al., 2002). The aerosol climatology of optical/radiative parameters and their vertical distribution are used for estimating aerosol radiative forcing (ARF) and atmospheric heating rates by using a discrete-ordinate radiative transfer model (Ricchiazzi et al., 1998, Pandithurai et al. 2004). Details of the experimental methods, data, results of aerosol climatology and implications to radiative forcing and associated heating rates will be presented. References Devara, P

  16. A Direct Heat Exchanger Unit used for Domestic Hot Water Supply in a Single-family House Supplied by Low Energy District Heating

    Brand, Marek; Thorsen, Jan Eric; Svendsen, Svend


    on the testing of the dynamic behaviour of an Instantaneous Heat Exchanger Unit(IHEU) designed for DHW heating and space heating in detached family houses supplied by LEDH ensuring an entry-to-substation temperature of 51 °C. We measured the time it takes for the IHEU to produce DHW with a temperature of 42 °C......The increasing number of new and renovated buildings with reduced heating requirements will soon make traditional District Heating (DH) systems uneconomic. To keep DH competitive in the future, the heat loss in DH networks needs to be reduced. One option is to reduce the supply temperature of DH...... as much as possible. This requires a review of the behaviour of the whole domestic hot water (DHW) supply system with focus on the user comfort and overall costs. This paper describes some practical approaches to the implementation of this Low Energy District Heating (LEDH) concept. It reports...

  17. Influence of staged-air on airflow, combustion characteristics and NO(x) emissions of a down-fired pulverized-coal 300 MW(e) utility boiler with direct flow split burners.

    Li, Zhengqi; Kuang, Min; Zhang, Jia; Han, Yunfeng; Zhu, Qunyi; Yang, Lianjie; Kong, Weiguang


    Cold airflow experiments were conducted to investigate the aerodynamic field in a small-scale furnace of a down-fired pulverized-coal 300 MW(e) utility boiler arranged with direct flow split burners enriched by cyclones. By increasing the staged-air ratio, a deflected flow field appeared in the lower furnace; larger staged-air ratios produced larger deflections. Industrial-sized experiments on a full-scale boiler were also performed at different staged-air damper openings with measurements taken of gas temperatures in the burner region and near the right-side wall, wall heat fluxes, and gas components (O(2), CO, and NO(x)) in the near-wall region. Combustion was unstable at staged-air damper openings below 30%. For openings of 30% and 40%, late ignition of the pulverized coal developed and large differences arose in gas temperatures and heat fluxes between the regions near the front and rear walls. In conjunction, carbon content in the fly ash was high and boiler efficiency was low with high NO(x) emission above 1200 mg/m(3) (at 6% O(2) dry). For fully open dampers, differences in gas temperatures and heat fluxes, carbon in fly ash and NO(x) emission decreased yielding an increase in boiler efficiency. The optimal setting is fully open staged-air dampers.

  18. Engineered Osmosis for Energy Efficient Separations: Optimizing Waste Heat Utilization FINAL SCIENTIFIC REPORT DOE F 241.3



    The purpose of this study is to design (i) a stripper system where heat is used to strip ammonia (NH{sub 3}) and carbon dioxide (CO{sub 2}) from a diluted draw solution; and (ii) a condensation or absorption system where the stripped NH{sub 3} and CO{sub 2} are captured in condensed water to form a re-concentrated draw solution. This study supports the Industrial Technologies Program of the DOE Office of Energy Efficiency and Renewable Energy and their Industrial Energy Efficiency Grand Challenge award solicitation. Results from this study show that stimulated Oasys draw solutions composed of a complex electrolyte solution associated with the dissolution of NH{sub 3} and CO{sub 2} gas in water can successfully be stripped and fully condensed under standard atmospheric pressure. Stripper bottoms NH{sub 3} concentration can reliably be reduced to < 1 mg/L, even when starting with liquids that have an NH{sub 3} mass fraction exceeding 6% to stimulate diluted draw solution from the forward osmosis membrane component of the process. Concentrated draw solution produced by fully condensing the stripper tops was show to exceed 6 M-C with nitrogen-to-carbon (N:C) molar ratios on the order of two. Reducing the operating pressure of the stripper column serves to reduce the partial vapor pressure of both NH{sub 3} and CO{sub 2} in solution and enables lower temperature operation towards integration of industrial low-grade of waste heat. Effective stripping of solutes was observed with operating pressures as low as 100 mbar (3-inHg). Systems operating at reduced pressure and temperature require additional design considerations to fully condense and absorb these constituents for reuse within the Oasys EO system context. Comparing empirical data with process stimulation models confirmed that several key parameters related to vapor-liquid equilibrium and intrinsic material properties were not accurate. Additional experiments and refinement of material property databases within the

  19. Comparison of gold nanoparticle mediated photoporation: vapor nanobubbles outperform direct heating for delivering macromolecules in live cells.

    Xiong, Ranhua; Raemdonck, Koen; Peynshaert, Karen; Lentacker, Ine; De Cock, Ine; Demeester, Jo; De Smedt, Stefaan C; Skirtach, Andre G; Braeckmans, Kevin


    There is a great interest in delivering macromolecular agents into living cells for therapeutic purposes, such as siRNA for gene silencing. Although substantial effort has gone into designing nonviral nanocarriers for delivering macromolecules into cells, translocation of the therapeutic molecules from the endosomes after endocytosis into the cytoplasm remains a major bottleneck. Laser-induced photoporation, especially in combination with gold nanoparticles, is an alternative physical method that is receiving increasing attention for delivering macromolecules in cells. By allowing gold nanoparticles to bind to the cell membrane, nanosized membrane pores can be created upon pulsed laser illumination. Depending on the laser energy, pores are created through either direct heating of the AuNPs or by vapor nanobubbles (VNBs) that can emerge around the AuNPs. Macromolecules in the surrounding cell medium can then diffuse through the pores directly into the cytoplasm. Here we present a systematic evaluation of both photoporation mechanisms in terms of cytotoxicity, cell loading, and siRNA transfection efficiency. We find that the delivery of macromolecules under conditions of VNBs is much more efficient than direct photothermal disturbance of the plasma membrane without any noticeable cytotoxic effect. Interestingly, by tuning the laser energy, the pore size could be changed, allowing control of the amount and size of molecules that are delivered in the cytoplasm. As only a single nanosecond laser pulse is required, we conclude that VNBs are an interesting photoporation mechanism that may prove very useful for efficient high-throughput macromolecular delivery in live cells.

  20. Thermal sensitivity analysis data utilizing Q10 scanning, Boltzmann slope factor and the change of molar heat capacity.

    Kang, KyeongJin


    As a further elaboration of the recently devised Q10 scanning analysis ("Exceptionally high thermal sensitivity of rattlesnake TRPA1 correlates with peak current amplitude" [1]), the interval between current data points at two temperatures was shortened and the resulting parameters representing thermal sensitivities such as peak Q10s and temperature points of major thermosensitivity events are presented for two TRPA1 orthologues from rattlesnakes and boas. In addition, the slope factors from Boltzmann fitting and the change of molar heat capacity of temperature-evoked currents were evaluated and compared as alternative ways of thermal sensitivity appraisal of TRPA1 orthologues.

  1. Geothermal heating systems for greenhouses

    Silva, J.F.; Johnson, W.C.


    Ways to utilize low-temperature geothermally heated water for a flow-through system are presented. The geothermal energy used for this system is the waste heat discharged from space heating 500,000 square feet of floor space at Oregon Institute of Technology with geothermal water pumped directly from the campus wells. The information collected and analyzed is from data developed from operating a greenhouse on the Oregon Institute of Technology campus from December 1979 to April 1980. Methods for calculating heating requirements of greenhouses using geothermal energy were developed from the analyses of the data obtained. (MHR)

  2. Relationship between heat-induced fibrillogenicity and hemolytic activity of thermostable direct hemolysin and a related hemolysin of Vibrio parahaemolyticus.

    Ohnishi, Kiyouhisa; Nakahira, Kumiko; Unzai, Satoru; Mayanagi, Kouta; Hashimoto, Hiroshi; Shiraki, Kentaro; Honda, Takeshi; Yanagihara, Itaru


    The formation of nonspecific ion channels by small oligomeric amyloid intermediates is toxic to the host's cellular membranes. Thermostable direct hemolysin (TDH) and TDH-related hemolysin (TRH) are major virulence factors of Vibrio parahaemolyticus. We have previously reported the crystal structure of TDH tetramer with the central channel. We have also identified the molecular mechanism underlying the paradoxical responses to heat treatment of TDH, known as the Arrhenius effect, which is the reversible amyloidogenic property. In the present report, we describe the biophysical properties of TRH, which displays 67% amino acid similarity with TDH. Molecular modeling provided a good fit of the overall structure of TDH and TRH. Size-exclusion chromatography, ultracentrifugation, and transmission electron microscopy revealed that TRH formed tetramer in solution. These toxins showed similar hemolytic activity on red blood cells. However, TRH had less amyloid-like structure than TDH analyzed by thioflavin T-binding assay and far-UV circular dichroism spectra. These data indicated that amyloidogenicity upon heating is not essential for the membrane disruption of erythrocytes, but the maintenance of tetrameric structure is indispensable for the hemolytic activity of the TDH and TRH.

  3. Protection of mice from oral Candidiasis by heat-killed enterococcus faecalis, possibly through its direct binding to Candida albicans.

    Ishijima, Sanae A; Hayama, Kazumi; Ninomiya, Kentaro; Iwasa, Masahiro; Yamazaki, Masatoshi; Abe, Shigeru


    To develop a new therapy against oral candidiasis, a commensal microorganism, Enterococcus faecalis was tested for its ability to modulate Candida growth in vitro and its therapeutic activities against a murine model in vivo. Addition of heat-killed E. faecalis strain EF2001 (EF2001) isolated from healthy human feces to the culture of C. albicans strain TIMM1768 inhibited adherence of the latter to a microtiter plate in a dose dependent manner and Candida cells surrounded by EF2001 were increased. To examine the protective activities of EF2001 in vivo, heat-killed EF2001 was applied orally before and after inoculation of Candida to the tongue of mice previously immunosuppressed. Two days after inoculation this inoculation, both the symptom score and CFU from swabbed-tongue were significantly reduced in the EF2001-treated animals. Histological analysis indicated that EF2001 may potentiate the accumulation of polymorphnuclear cells near a Candida-infected region. These results suggest that oral administration of EF2001 has protective activity against oral candidiasis and that the in vivo activity may be reflected by direct interaction between EF2001 and Candida cells in vitro and the potentiation of an immunostimulatory effect of EF2001.

  4. Numerical simulation of heat transfer and fluid flow in coaxial laser cladding process for direct metal deposition

    Qi, Huan; Mazumder, Jyotirmoy; Ki, Hyungson


    The coaxial laser cladding process is the heart of direct metal deposition (DMD). Rapid materials processing, such as DMD, is steadily becoming a tool for synthesis of materials, as well as rapid manufacturing. Mathematical models to develop the fundamental understanding of the physical phenomena associated with the coaxial laser cladding process are essential to further develop the science base. A three-dimensional transient model was developed for a coaxial powder injection laser cladding process. Physical phenomena including heat transfer, melting and solidification phase changes, mass addition, and fluid flow in the melt pool, were modeled in a self-consistent manner. Interactions between the laser beam and the coaxial powder flow, including the attenuation of beam intensity and temperature rise of powder particles before reaching the melt pool were modeled with a simple heat balance equation. The level-set method was implemented to track the free surface movement of the melt pool, in a continuous laser cladding process. The governing equations were discretized using the finite volume approach. Temperature and fluid velocity were solved for in a coupled manner. Simulation results such as the melt pool width and length, and the height of solidified cladding track were compared with experimental results and found to be reasonably matched.

  5. Reconfigurable intensity modulation and direct detection optical transceivers for variable-rate wavelength-division-multiplexing passive optical networks utilizing digital signal processing-based symbol mapper

    Zhang, Zhiguo; Zhang, Bingbing; Chen, Yanxu; Chen, Xue


    Variable-rate intensity modulation and direct detection-based optical transceivers with software-controllable reconfigurability and transmission performance adaptability are experimentally demonstrated, utilizing M-QAM symbol mapping implemented in MATLAB® programs. A frequency division multiplexing-based symbol demapping and wavelength management method is proposed for the symbol demapper and tunable laser management used in colorless optical network unit.

  6. A comparison of the heat and mechanical energy of a heat-pump wind turbine system

    Aybek, A.; Arslan, S.; Yildiz, E.; Atik, K. [University of Kahramanmaras (Turkey). Dept. of Agricultural Machinery


    While a variety of applications of wind energy have been studied in Turkey, no significant efforts have been made to utilize heat pumps for heat generation. The use of heat pumps in wind energy systems is worth considering because of the high efficiency of heat production. In this study, a directly coupled wind turbine-heat pump system was designed, constructed, and tested. Measurements determined the mechanical energy of the rotors of the wind turbine and the heat energy generated by the heat pump driven by the rotor shaft. Based on the comparisons between the power generated by the heat pump and the power of the Savonius rotors, it was found that the heat energy gained by the heat pump was four times greater than the mechanical energy obtained from the turbine. It was suggested that heat pumps could be efficiently used in wind energy systems. (Author)

  7. An analytical model of beam attenuation and powder heating during coaxial laser direct metal deposition

    Pinkerton, Andrew J.


    In the laser direct metal deposition process, interaction between the laser beam and powder from a coaxial powder delivery nozzle alters the temperature of powder and the amount and spatial distribution of laser intensity reaching the deposition melt pool. These factors significantly affect the process and are also important input parameters for any finite element or analytical models of the melt pool and deposition tracks. The analytical model in this paper presents a method to calculate laser attenuation and powder temperatures at every point below such a nozzle. It is applicable to laser beams that are approximately parallel over the beam-powder interaction distance of any initial intensity distribution (Top Hat, Gaussian, TEM01ast or other). The volume below the nozzle is divided into the region above the powder consolidation plane, where the powder stream is annular, and below it, where it is a single Gaussian stream, and expressions derived for each region. Modelled and measured results are reasonably matched. Results indicate that attenuation is more severe once the annular powder stream has consolidated into a single stream but is not zero before that point. The temperature of powder reaching any point is not constant but the mean value is a maximum at the centre of the stream.

  8. Scrap tyre recycling process with molten zinc as direct heat transfer and solids separation fluid: A new reactor concept.

    Riedewald, Frank; Goode, Kieran; Sexton, Aidan; Sousa-Gallagher, Maria J


    Every year about 1.5 billion tyres are discarded worldwide representing a large amount of solid waste, but also a largely untapped source of raw materials. The objective of the method was to prove the concept of a novel scrap tyre recycling process which uses molten zinc as the direct heat transfer fluid and, simultaneously, uses this media to separate the solids products (i.e. steel and rCB) in a sink-float separation at an operating temperature of 450-470 °C. This methodology involved: •construction of the laboratory scale batch reactor,•separation of floating rCB from the zinc,•recovery of the steel from the bottom of the reactor following pyrolysis.

  9. Resolution of the direct containment heating issue for all Westinghouse plants with large dry containments or subatmospheric containments

    Pilch, M.M.; Allen, M.D.; Klamerus, E.W. [Sandia National Labs., Albuquerque, NM (United States)


    This report uses the methodology and scenarios described in NUREG/CR-6075 and NUREG/CR-6075, Supplement 1, to address the direct containment heating (DCH) issue for all Westinghouse plants with large dry or subatmospheric containments. DCH is considered resolved if the conditional containment failure probability (CCFP) is less than 0.1. The methodology calls for an initial screening phase in which the CCFP for each plant is calculated based on loads versus strength evaluations using plant-specific information. The DCH issue is considered resolved for a plant if the CCFP calculated in the screening phase is less than 0.01. This value is more stringent than the overall success criterion of 0.1. The CCFPs for all of the Westinghouse plants with dry containments were less than 0.01 in the screening phase calculations, and thus, the DCH issue is resolved for these plants based on containment loads alone. No additional analyses are required.

  10. Waste heat utilization in the thermal spa of Lavey-les-Bains; Etude de la valorisation des rejets thermiques des Bains de Lavey



    This final report for the Swiss Federal Office of Energy looks at the possibilities for improved waste water utilization in the Lavey-les-Bains thermal spa, Switzerland. According to the regulations in force, the temperature of the waste water rejected into the Rhone river shall not exceed 30 {sup o}C, what is currently not the case. Also the operational cost shall be reduced and the waste water quality improved. The installations are presented. From the two geothermal wells, mineral water comes out at an average flow rate of 940 l/min and a temperature of 63 {sup o}C. Actual waste water data are reported. The measured thermal water consumption data, including seasonal variations, are analysed by computerized simulation and measures to reduce the consumed volume by the optimization of internal procedures are evaluated. Measures to reduce the quantity of the rejected free chlorine are discussed. Several possible adaptations of the existing space heating, domestic water heating and pools' heating are evaluated, including cost. In addition, extensions of the thermal spa center to recreational activities are discussed, as the construction of a tropical greenhouse is.

  11. The utilization of excess wind-electric power from stock water pumping systems to heat a sector of the stock tank

    Nydahl, J.E.; Carlson, B.O. [Univ. of Wyoming, Laramie, WY (United States)


    On the high plains, a wind-electric stock water pumping system produces a significant amount of excess power over the winter months due to intense winds and the decreased water consumption by cattle. The University of Wyoming is developing a multi-tasking system to utilize this excess energy to resistively heat a small sector of the stock tank at its demonstration/experimental site. This paper outlines the detailed heat transfer analysis that predicted drinking water temperature and icing conditions. It also outlines the optimization criteria and the power produced by the Bergey 1500 wind electric system. Results show that heating a smaller insulated tank inserted into the larger tank would raise the drinking water temperature by a maximum of 6.7 {degrees}C and eliminate icing conditions. The returns associated with the additional cattle weight gain, as a result of the consumption of warmer water, showed that system modification costs would be recovered the first year. 12 refs., 11 figs., 2 tabs.

  12. A Comparison of Importance Weights for Multiattribute Utility Analysis Derived from Holistic, Indifference, Direct Subjective and Rank Order Judgments.


    attribute utility analysis ( MAUA ) models such subjective value judgments by eliciting value relevant attributes of the objects or acts, by assessing...single-attri- bute utilities and weights, and by aggregating these inputs into an overall value index. Proponents of MAUA argue that the choices...dictated by MAUA will, on the average, yield more favorable consequences than choices based on other types of evaluations, e.g., intuition. However, since

  13. Self-ignition combustion synthesis of LaNi{sub 5} utilizing hydrogenation heat of metallic calcium

    Yasuda, Naoto; Sasaki, Shino; Okinaka, Noriyuki; Akiyama, Tomohiro [Center for Advanced Research of Energy and Materials, Hokkaido University, Kita 13 Nishi 8, Kita-ku, Sapporo, Hokkaido 060-8628 (Japan)


    This paper describes self-ignition combustion synthesis (SICS) of LaNi{sub 5} in a pressurized hydrogen atmosphere using metallic calcium as both the reducing agent and the heat source. In this study, the effects of hydrogen on the ignition temperature and the hydrogenation properties of the products were mainly examined. In the experiments, La{sub 2}O{sub 3}, Ni, and Ca were dry-mixed in the molar ratio of 1:10:6 and then heated up at a hydrogen pressure of 1.0 MPa until the ignition due to the hydrogenation of calcium. For the sake of comparison, the same experiments were performed in a normal argon atmosphere. The results showed that the ignition temperature was drastically lowered by hydrogen; it was only 600 K in the case of hydrogen as compared to 1100 K in the case of argon. The products also exhibited high initial activity and hydrogen storage capacity of 1.54 mass%. The proposed method offers many benefits for using cost-effective rare-earth oxide, saving productive time and energy, improving initial activity of the product and applying to any AB{sub 5}-type hydrogen storage alloy. (author)

  14. Study on heat collector of the solar system utilizing outdoor air. Experimental results in cases of cold and warm regions; Gaiki donyushiki solar system no shunetsubu ni kansuru kenkyu. Kanreichi to ondanchi ni okeru shunetsu jikken to kosatsu

    Komano, S.; Ebara, Y. [OM Solar Association, Shizuoka (Japan); Wada, H. [Wada Building Constructors Co. Ltd., Hokkaido (Japan)


    An experiment on heat collection was made in the heat collector of a solar system utilizing outdoor air in cold and warm regions. In this system, outdoor air is heated by the air circulation layer on the roof exposed to solar radiation. The heated air is supplied to the object space for heating and ventilation. In the experiment in a cold region, the heat collection characteristics can be adjusted by putting a baffle plate in the air duct according to the experiment of a glass heat collector. The heat collecting air layer on only the iron roof may leak or freeze in the region subject to coldness or heavy snowfall. Therefore, preheat forms the space of a garret, and the preheat temperature comparatively becomes low. The data in which the heat collection characteristics can be adjusted using only a glass heat collector is required corresponding to the regional situation. In the experiment in a warm region, an experiment was made inclusive of the preheat for which outdoor air is absorbed at the eaves. As a result, the heat collection characteristics of preheat were improved. Moreover, a heat collection temperature of about 60{degree}C was obtained on the heat collection surface including the preheat. 1 ref., 12 figs., 3 tabs.

  15. Transurethral ultrasound applicators with directional heating patterns for prostate thermal therapy: in vivo evaluation using magnetic resonance thermometry.

    Diederich, C J; Stafford, R J; Nau, W H; Burdette, E C; Price, R E; Hazle, J D


    A catheter-based transurethral ultrasound applicator with angularly directional heating patterns has been designed for prostate thermal therapy and evaluated in canine prostate in vivo using MRI to monitor and assess performance. The ultrasound transducer array (3.5 mm diameter tubular transducers, 180 degrees active sectors, approximately 7.5 MHz) was integrated to a flexible delivery catheter (4 mm OD), and encapsulated within an expandable balloon (35 mm x 10 mm OD, 80 ml min(-1) ambient water) for coupling and cooling of the prostatic urethra. These devices were used to thermally coagulate targeted portions of the canine prostate (n = 2) while using MR thermal imaging (MRTI) to monitor the therapy. MRI was also used for target definition, positioning of the applicator, and evaluation of target viability post-therapy. MRTI was based upon the complex phase-difference mapping technique using an interleaved gradient echo-planar imaging sequence with lipid suppression. MRTI derived temperature distributions, thermal dose exposures, T1-contrast enhanced MR images, and histology of sectioned prostates were used to define destroyed tissue zones and characterize the three-dimensional heating patterns. The ultrasound applicators produced approximately 180 degrees directed zones of thermal coagulation within targeted tissue which extended 15-20 mm radially to the outer boundary of the prostate within 15 min. Transducer activation lengths of 17 mm and 24 mm produced contiguous zones of coagulation extending axially approximately 18 mm and approximately 25 mm from base to apex, respectively. Peak temperatures around 90 degrees C were measured, with approximately 50 degrees C-52 degrees C corresponding to outer boundary t43 = 240 min at approximately 15 min treatment time. These devices are MRI compatible, and when coupled with multiplanar MRTI provide a means for selectively controlling the length and sector angle of therapeutic thermal treatment in the prostate.

  16. 重整C9芳烃分馏塔冷凝潜热综合利用新工艺%Integrated utilizing process for condensation latent heat of reforming C9 arene fractionating column

    赵永祥; 侯敏; 杜颖


    基于重整C9芳烃分离装置塔顶油气冷凝潜热的特点,分析对比现有换热工艺及几种新的节能新工艺,研究发现,利用二塔塔顶油气生产0.4 MPa饱和水蒸气,二塔塔釜分别设加热热源工艺和分馏塔热集成与塔顶油气生产0.4 MPa水蒸气联合运用工艺,二者节能效果相当,但是后者装置外提供的一次能量较前者小,因此分馏塔热集成与塔顶油气生产0.4 MPa水蒸气联合运用工艺更好.文中提出对于新建的重整C9芳烃分离装置可以采用分馏塔热集成与塔顶油气冷凝潜热生产水蒸气联合节能工艺,可以直接利用其分馏塔顶油气冷凝潜热生产水蒸气,以降低能耗,由重整C9芳烃塔顶油气潜热所生产的0.4 MPa水蒸气可以直接使用,也可以通过压缩机进行提温提压后,并入低压蒸汽管网;对于现有装置可以通过改造,直接利用分馏塔顶油气生产水蒸气,其节能效果也十分明显.%Based on the condensation latent heat characteristics of fractionating column top oil gas in C9 arenes separating unit, the existing heat transfer technologies and several new energy-saving technologies were analyzed and compared. The research shows that the technology with 0.4 Mpa saturated steam produced from two-column top oil gas and two-column bottom heated with different heat sources and the technology with 0.4 Mpa saturated steam produced from two-column top oil gas and utilizing integrated heat from fractionating column both are obviously agreed in energy saving. But, the latter needs less primary power provided from outside apparatus. So this technology is better. Both heat-integrated distillation technology and steam production technology by using latent heat energy can be used in new C9 arenes distillation plant, from which the vapor can be produced directly from condensation latent heat to decrease energy consumption. The produced 0.4 Mpa steam can be directly used in the plant or sent into the low

  17. Ball cocks for subsurface installation for utilization in district heating grids; Erdeinbau-Kugelhaehne fuer den Einsatz in Fernwaerme-Netzen

    Burg, Albert


    As shut-off valves in buried pipelines, ball cocks are used almost exclusively. The rated caliber is between DN 20 and DN 1000. The problem in district heating grids consists in the fact that shut-off valves are operated only in case of emergencies or during grid extensions, but it is very important that they function reliably in these critical conditions even after a life of 30 years. Another problem in district heating grids is the fact that the flow direction can be reversed, depending on the mode of operation of the grid. Fittings therefore must provide tight sealing on both sides. The contribution lists potential causes of damage and proposes countermeasures and preventive measures. (orig.)

  18. Power plant waste heat utilization in aquaculture. Semi-annual report, No. 2, 1 November 1977--1 June 1978

    Guerra, C.R.; Godfriaux, B.L.


    The principal objective is to evaluate, at proof-of-concept scale, the potential of intensive aquaculture operations using power plant thermal discharges to enhance productivity. The field experiments involve the rearing of rainbow trout (Salmo gairdneri), channel catfish (Ictalurus punctatus) and American eel (Anguilla rostrata) for successive periods (semi-annual) in accordance with the temperature of the thermal effluents. Striped bass (Morone saxatilis) and the freshwater shrimp (Macrobrachium rosenbergii) are also being tested in smaller, laboratory size culture systems. The above mentioned species were selected because of their economic importance. They will be evaluated for food quality and marketability with the cooperation of potential commercial users. Aquaculture facilities were constructed at a steam electric generating plant for studies determining use for waste heat released into condenser cooling water. Growth rates, food conversion ratios, disease problems and mortality rates are being studied in the project. (Color illustrations reproduced in black and white) (Portions of this document are not fully legible)

  19. Power plant waste heat utilization in aquaculture. Volume III. Final report, 1 November 1976-1 November 1979

    Farmanfarmaian, A.


    This report is part of a three year research study on the constructive use of electric generating station waste heat in cooling water effluents for fish production. It describes procedures and methods for the commercial culture of the giant fresh water shrimp, Macrobrachium rosenbergii, and the rainbow trout, Salmo gairdneri, in the thermal discharge water of the Mercer Power Plant in Trenton, New Jersey. Discharge water from this plant was used in a preliminary assessment of the survival, growth, and food conversion ratio of these species. It was shown that acute or chronic exposure to power plant intake and discharge water; discharge with or without coal particles; and discharge with or without slurry overflow mix does not significantly affect metabolism, short-term survival, growth, or conversion efficiency of shrimp or trout.

  20. Utilization of the Net Heat Process Tail Gases in the Reactor for the Production of Oil-Furnace Carbon Black

    Bosak, Z.


    Full Text Available Tail gases of low calorific value, which are the by-product of oil-furnace carbon black industrial production, can be efficiently used as energy before their final release into the atmosphere. Apart from being used mainly for heating dryers, production of steam, electricity, or flared, they can also be used as a substitute for fuel in the reactor for the production of oil-furnace carbon blacks, thus increasing the efficiency of the hydrocarbon raw feedstock.This technical paper represents the technical-technological solution for applying the waste heat of the low calorific tail gases in the reactor for the production of "hard" grade oil-furnace carbon blacks with savings of the hydrocarbon raw feedstock.The introduction of the preheated low calorific tail gases in the reactor for the production of "hard" grade oil-furnace carbon blacks is achieved by serial cascading of four fans. The system consists of fans designed to pneumatically transport the mixture of process tail gases and oil-furnace carbon black dust particles. This ensures a stable technological process for the introduction of the low calorific process tail gases into the reaction zone where the natural gas and preheated air are combusted.In the production of oil-furnace carbon black N220, it is shown that by using low calorific process tail gases in the amount from 1000 to 2000 m3 h–1 per reactor, savings from 10 to 20 % of natural gas and simultaneously 7 to 9 % of the hydrocarbon raw feedstoks were achieved.

  1. ECOLO-HOUSE in the snowy town. Study of the ventilating function what the heat collecting system of the air duct utilizing attic has; Yukiguni ECOLO-HOUSE. Kison kaoku no yaneura wo riyoshita duct shunetsu system

    Umemiya, H.; Hirosawa, K. [Yamagata University, Yamagata (Japan)


    Described in this paper is an air duct heat collecting system, forming a link in the chain of natural energy utilization, in an attic of a house actually in presence. When a sirocco fan (blowing air from an indoor induction duct into the room) at the base of the highblocked floor is turned, air is sucked through an air intake under the eaves into a heat collecting duct (constructed utilizing the tilt roof and rafter). Heat from the roof warmed by sunshine is absorbed by air in the heat collecting duct and is fed to the highblocked floor structure through a heat collecting room and the induction duct. This system functions quite effectively as a ventilating device. Dew condensation on the walls and floor and musty smell have been eliminated. This system is good enough as a heater even on chilly days in early spring when there is sunshine. In the time zone with the sun shining, the system collects 4{times}10{sup 4}kJ per day, exhibiting a heat collecting efficiency of 4%. The heat collecting duct was analyzed for thermal environment, and the heat flux of the collected heat was determined as Qk(W/m{sup 2}=0.1{times}I-1.3{Theta}d-{Theta}a). In this equation, I is the quantity of insolation (W/m{sup 2}), {Theta}d is the temperature in the heat collecting duct, and {Theta}a is the free air temperature. 2 refs., 8 figs.

  2. Counterflow Regolith Heat Exchanger

    Zubrin, Robert; Jonscher, Peter


    A problem exists in reducing the total heating power required to extract oxygen from lunar regolith. All such processes require heating a great deal of soil, and the heat energy is wasted if it cannot be recycled from processed material back into new material. The counterflow regolith heat exchanger (CoRHE) is a device that transfers heat from hot regolith to cold regolith. The CoRHE is essentially a tube-in-tube heat exchanger with internal and external augers attached to the inner rotating tube to move the regolith. Hot regolith in the outer tube is moved in one direction by a right-hand - ed auger, and the cool regolith in the inner tube is moved in the opposite direction by a left-handed auger attached to the inside of the rotating tube. In this counterflow arrangement, a large fraction of the heat from the expended regolith is transferred to the new regolith. The spent regolith leaves the heat exchanger close to the temperature of the cold new regolith, and the new regolith is pre-heated close to the initial temperature of the spent regolith. Using the CoRHE can reduce the heating requirement of a lunar ISRU system by 80%, reducing the total power consumption by a factor of two. The unique feature of this system is that it allows for counterflow heat exchange to occur between solids, instead of liquids or gases, as is commonly done. In addition, in variants of this concept, the hydrogen reduction can be made to occur within the counterflow heat exchanger itself, enabling a simplified lunar ISRU (in situ resource utilization) system with excellent energy economy and continuous nonbatch mode operation.

  3. Development of Direct-Use Projects: Preprint

    Lund, J.


    A geothermal direct-use project utilizes a natural resource, a flow of geothermal fluid at elevated temperatures, which is capable of providing heat and/or cooling to buildings, greenhouses, aquaculture ponds, and industrial processes. Geothermal utilization requires matching the varied needs of the user and characteristics of the resource in order to development a successful project. Each application is unique; guidelines are provided for the logical steps required to implement a project. Recommended temperature and flows are suggested for spas and pools, space and district heating, greenhouse and aquaculture pond heating, and industrial applications. Guidelines are provided for selecting the necessary equipment for successfully implementing a direct-use project, including downhole pumps, piping, heat exchangers, and heat convectors. Additionally, the relationship between temperature, flow rate, and the use of heat exchangers to provide heat to a space with hot water or hot air is provided for a number of applications, with suggested 'rules of thumb'.

  4. Preconversion processing of bituminous coals: New directions to improved direct catalytic coal liquefaction. [Effect of preconversion heat soak with coal liquids


    A study of the high-temperature soaking started in this quarter, following the installation of reactors in the previous quarter. Two high-volatile bituminous coals and three coal liquids, which were identified in the previous report, were used. A cross-linked, three-dimensional macromolecular model has been widely accepted f or the structure of coal, but there is no direct evidence to prove this model. The conventional coal structure model has been recently re-examined by this investigator because of the importance of relatively strong intra- and intermolecular interactions in bituminous coals. It was reasonable to deduce that significant portions were physically associated after a study of multistep extractions, associative equilibria, the irreversibility and the dependence of coal concentration on solvent swelling, and consideration of the monophase concept. Physical dissociation which may be significant above 300{degree}C should be utilized for the treatment before liquefaction. The high-temperature soaking in a recycle oil was proposed to dissociate coal complexes.

  5. Containment loads due to direct containment heating and associated hydrogen behavior: Analysis and calculations with the CONTAIN code

    Williams, D C; Bergeron, K D; Carroll, D E; Gasser, R D; Tills, J L; Washington, K E


    One of the most important unresolved issues governing risk in many nuclear power plants involves the phenomenon called direct containment heating (DCH), in which it is postulated that molten corium ejected under high pressure from the reactor vessel is dispersed into the containment atmosphere, thereby causing sufficient heating and pressurization to threaten containment integrity. Models for the calculation of potential DCH loads have been developed and incorporated into the CONTAIN code for severe accident analysis. Using CONTAIN, DCH scenarios in PWR plants having three different representative containment types have been analyzed: Surry (subatmospheric large dry containment), Sequoyah (ice condenser containment), and Bellefonte (atmospheric large dry containment). A large number of parameter variation and phenomenological uncertainty studies were performed. Response of DCH loads to these variations was found to be quite complex; often the results differ substantially from what has been previously assumed concerning DCH. Containment compartmentalization offers the potential of greatly mitigating DCH loads relative to what might be calculated using single-cell representations of containments, but the actual degree of mitigation to be expected is sensitive to many uncertainties. Dominant uncertainties include hydrogen combustion phenomena in the extreme environments produced by DCH scenarios, and factors which affect the rate of transport of DCH energy to the upper containment. In addition, DCH loads can be aggravated by rapid blowdown of the primary system, co-dispersal of moderate quantities of water with the debris, and quenching of de-entrained debris in water; these factors act by increasing steam flows which, in turn, accelerates energy transport. It may be noted that containment-threatening loads were calculated for a substantial portion of the scenarios treated for some of the plants considered.

  6. A technical analysis for cogeneration systems with potential applications in twelve California industrial plants. [energy saving heat-electricity utility systems

    Moretti, V. C.; Davis, H. S.; Slonski, M. L.


    In a study sponsored by the State of California Energy Resources Conservation and Development Commission, 12 industrial plants in five utility districts were surveyed to assess the potential applications of the cogeneration of heat and electricity in California industry. Thermodynamic calculations were made for each plant in determining the energy required to meet the existing electrical and steam demands. The present systems were then compared to conceptual cogeneration systems specified for each plant. Overall energy savings were determined for the cogeneration applications. Steam and gas turbine topping cycle systems were considered as well as bottoming cycle systems. Types of industries studied were: pulp and paper, timber, cement, petroleum refining, enhanced oil recovery, foods processing, steel and glass

  7. Milestone Report #2: Direct Evaporator Leak and Flammability Analysis Modifications and Optimization of the Organic Rankine Cycle to Improve the Recovery of Waste Heat

    Donna Post Guillen


    The direct evaporator is a simplified heat exchange system for an Organic Rankine Cycle (ORC) that generates electricity from a gas turbine exhaust stream. Typically, the heat of the exhaust stream is transferred indirectly to the ORC by means of an intermediate thermal oil loop. In this project, the goal is to design a direct evaporator where the working fluid is evaporated in the exhaust gas heat exchanger. By eliminating one of the heat exchangers and the intermediate oil loop, the overall ORC system cost can be reduced by approximately 15%. However, placing a heat exchanger operating with a flammable hydrocarbon working fluid directly in the hot exhaust gas stream presents potential safety risks. The purpose of the analyses presented in this report is to assess the flammability of the selected working fluid in the hot exhaust gas stream stemming from a potential leak in the evaporator. Ignition delay time for cyclopentane at temperatures and pressure corresponding to direct evaporator operation was obtained for several equivalence ratios. Results of a computational fluid dynamic analysis of a pinhole leak scenario are given.

  8. Direct utilization of geothermal resources at Warm Springs State Hospital, Warm Springs, Montana. Final report, January 31, 1979-June 30, 1983


    Several decades ago the water from a natural hot spring was piped to the Warm Springs State Hospital barn and greenhouse and eventually into the domestic water supply for showers. The Montana Department of Natural Resources and Conservation (DNRC) funded a feasibility study on potential development of the geothermal resource from monies originating from coal severence taxes. The results of the feasibility study were subsequently utilized in obtaining a $721,122 award from the Department of Energy Program Opportunity Notice (PON) program to identify and develop the geothermal resource at Warm Springs. The study included environmental and legal considerations, geophysical surveys, and the subsequent development of the resource. The well produces 60 to 64 gpm of 154/sup 0/F geothermal water which is utilized in a heat exchanger to heat domestic water. The system became fully operational on January 13, 1983 and the calculated yearly energy savings represent approximately 17.6 million cubic feet of natural gas which is equivalent to $77,000, based on current prices.

  9. Incineration and its heat utilization for sludge and spent grains recycling. Beer kasu dassui odei shokyakunetsu no yuko riyo

    Ogawa, T. (Asahi Breweries, Ltd., Tokyo (Japan))


    This paper introduces a case of effectively utilizing dehydrated sludge and spent grains as a boiler fuel, and industrial wastes from breweries to reduce the amount of wastes. These wastes show as high water content as 80% to 83%, but dried wastes are constituted of hydrocarbon, excepting ash. Especially beer spent grains have a calorific power of close to 5000 kcal/kg. The key point is how to blow off water efficiently (existence of a dehydration and drying process accompanies such advantages and disadvantages as facility simplification, necessity of auxiliary fuels, and generation of high-BOD water associated with beer lees dehydration). As a result of discussions and tests, a fluidized bed boiler (with a pressure of 14 kg/cm[sup 2] at a flow rate of 8.1 t/h) was adopted. Wastes to be burned dry up before they reach the floor of a fluidized furnace and are burned on the floor, and any unburned components are burned completely in a secondary combustion chamber. The boiler has been operating smoothly since the operation has started in 1989. An integrating comparison of various costs has resulted in annual economy of 81 million yen. 7 figs., 5 tabs.

  10. Simultaneous production and utilization of methanol for methyl formate synthesis in a looped heat exchanger reactor configuration

    A.Goosheneshin; R.Maleki; D.Iranshahi; M.R.Rahimpour; A.Jahanmiri


    In this investigation,a novel thermally coupled reactor (TCR) containing methyl formate (MF) production in the endothermic side and methanol synthesis in the exothermic side has been investigated.The interesting feature of this TCR is that productive methanol in the exothermic side could be recycled and used as feed of endothermic side for MF synthesis.Other important advantages of the proposed system are high production rates of hydrogen and MF.The configuration consists of two thermally coupled concentric tubular reactors.In these coupled reactors,autothermal system is obtained within the reactor.A steady-state heterogeneous model is used for simulation of the coupled reactor.The proposed model has been utilized to compare the performance of TCR with the conventional methanol reactor (CMR).Noticeable enhancement can be obtained in the performance of the reactors.The influence of operational parameters is studied on reactor performance.The results show that coupling of these reactions could be feasible and beneficial.Experimental proof-of-concept is required to validate the operation of the novel reactor.

  11. Simulation and economic analysis of a liquid-based solar system with a direct-contact liquid-liquid heat exchanger, in comparison to a system with a conventional heat exchanger

    Brothers, P.; Karaki, S.

    Using a solar computer simulation package called TRNSYS, simulations of the direct contact liquid-liquid heat exchanger (DCLLHE) solar system and a system with conventional shell-and-tube heat exchanger were developed, based in part on performance measurements of the actual systems. The two systems were simulated over a full year on an hour-by-hour basis at five locations; Boston, Massachusetts, Charleston, South Carolina, Dodge City, Kansas, Madison, Wisconsin, and Phoenix, Arizona. Typically the direct-contact system supplies slightly more heat for domestic hot water and space heating in all locations and about 5 percentage points more cooling as compared to the conventional system. Using a common set of economic parameters and the appropriate federal and state income tax credits, as well as property tax legislation for solar systems in the corresponding states, the results of the study indicate for heating-only systems, the DCLLHE system has a slight life-cycle cost disadvantage compared to the conventional system. For combined solar heating and cooling systems, the DCLLHE has a slight life-cycle cost advantage which varies with location and amounts to one to three percent difference from the conventional system.

  12. Fundamental analysis of thermally regenerative fuel cell utilizing solar heat; Taiyonetsu wo riyosuru netsu saiseigata nenryo denchi no kiso tokusei no kaiseki

    Ando, Y.; Tanaka, T.; Takashima, T.; Doi, T. [Electrotechnical Laboratory, Tsukuba (Japan); Aosawa, T.; Kogoshi, S. [Science University of Tokyo, Tokyo (Japan)


    Study was made on a thermally regenerative fuel cell using solar heat. The thermally regenerative fuel cell was devised which is composed of 2-propanol liquid-phase endothermic dehydrogenation at nearly 100degC, and acetone liquid- phase exothermic hydrogenation at nearly 30degC as reverse reaction. This low-temperature dehydrogenation can relatively easily utilize a flat solar heat concentrator. 2-propanol dehydrogenation generates acetone and hydrogen. Generated acetone generates electric power in hydrogenation, generating propanol. This propanol regenerates acetone and hydrogen in dehydrogenation. The activity of Ru and Pt composite catalyst was considerably higher than that of Ru or Pt single catalyst. The activity was also higher in carbon felt or carbon cloth carrier than carbon plate carrier. The open circuit voltage of the fuel cell was estimated to be 110-120mV, nearly consisting with theoretical values. Short circuit current was also estimated to be 9-11mA, suggesting reduction of its internal resistance as an important subject. 4 refs., 5 figs., 2 tabs.

  13. An unsymmetrical non-fullerene acceptor: synthesis via direct heteroarylation, self-assembly, and utility as a low energy absorber in organic photovoltaic cells.

    Payne, Abby-Jo; Li, Shi; Dayneko, Sergey V; Risko, Chad; Welch, Gregory C


    This study reports on the design and synthesis of an unsymmetrical π-conjugated organic molecule composed of perylene diimide, thienyl diketopyrrolopyrrole, and indoloquinoxaline pieced together using direct heteroarylation. This material demonstrates unprecedented response in the thin-film upon post-deposition solvent vapor annealing, resulting in dramatic red-shifts in optical absorption. Such changes were utilized to enhance photocurrent generation in P3HT based organic solar cells.

  14. On the Analysis and Evaluation of Direct Containement Heating with the Multidimensional Multiphase Flow Code MC3D

    Tanguy Janin


    Full Text Available In the course of a postulated severe accident in an NPP, Direct Containment Heating (DCH may occur after an eventual failure of the vessel. DCH is related to dynamical, thermal, and chemical phenomena involved by the eventual fine fragmentation and dispersal of the corium melt out of the vessel pit. It may threaten the integrity of the containment by pressurization of its atmosphere. Several simplified modellings have been proposed in the past but they require a very strong fitting which renders any extrapolation regarding geometry, material, and scales rather doubtful. With the development of multidimensional multiphase flow computer codes, it is now possible to investigate the phenomenon numerically with more details. We present an analysis of the potential of the MC3D code to support the analysis of this phenomenon, restricting our discussion to the dynamical processes. The analysis is applied to the case of French 1300 MWe PWR reactors for which we derive a correlation for the corium dispersal rate for application in a Probabilistic Safety Analysis (PSA level 2 study.

  15. Geothermal direct heat use: market potential/penetration analysis for Federal Region IX (Arizona, California, Hawaii, Nevada)

    Powell, W.; Tang, K. (eds.)


    A preliminary study was made of the potential for geothermal direct heat use in Arizona, California, Hawaii, and Nevada (Federal Region IX). The analysis for each state was performed by a different team, located in that state. For each state, the study team was asked to: (1) define the resource, based on the latest available data; (2) assess the potential market growth for geothermal energy; and (3) estimate the market penetration, projected to 2020. Each of the four states of interest in this study is unique in its own way. Rather than impose the same assumptions as to growth rates, capture rates, etc. on all of the study teams, each team was asked to use the most appropriate set of assumptions for its state. The results, therefore, should reflect the currently accepted views within each state. The four state reports comprise the main portion of this document. A brief regional overview section was prepared by the Jet Propulsion Laboratory, following completion of the state reports.

  16. Experiments to investigate direct containment heating phenomena with scaled models of the Calvert Cliffs Nuclear Power Plant

    Blanchat, T.K.; Pilch, M.M.; Allen, M.D.


    The Surtsey Test Facility is used to perform scaled experiments simulating High Pressure Melt Ejection accidents in a nuclear power plant (NPP). The experiments investigate the effects of direct containment heating (DCH) on the containment load. The results from Zion and Surry experiments can be extrapolated to other Westinghouse plants, but predicted containment loads cannot be generalized to all Combustion Engineering (CE) plants. Five CE plants have melt dispersal flow paths which circumvent the main mitigation of containment compartmentalization in most Westinghouse PWRs. Calvert Cliff-like plant geometries and the impact of codispersed water were addressed as part of the DCH issue resolution. Integral effects tests were performed with a scale model of the Calvert Cliffs NPP inside the Surtsey test vessel. The experiments investigated the effects of codispersal of water, steam, and molten core stimulant materials on DCH loads under prototypic accident conditions and plant configurations. The results indicated that large amounts of coejected water reduced the DCH load by a small amount. Large amounts of debris were dispersed from the cavity to the upper dome (via the annular gap). 22 refs., 84 figs., 30 tabs.

  17. High temperature thermal conductivity measurements of UO/sub 2/ by Direct Electrical Heating. Final report. [MANTRA-III

    Bassett, B


    High temperature properties of reactor type UO/sub 2/ pellets were measured using a Direct Electrical Heating (DEH) Facility. Modifications to the experimental apparatus have been made so that successful and reproducible DEH runs may be carried out while protecting the pellets from oxidation at high temperature. X-ray diffraction measurements on the UO/sub 2/ pellets have been made before and after runs to assure that sample oxidation has not occurred. A computer code has been developed that will model the experiment using equations that describe physical properties of the material. This code allows these equations to be checked by comparing the model results to collected data. The thermal conductivity equation for UO/sub 2/ proposed by Weilbacher has been used for this analysis. By adjusting the empirical parameters in Weilbacher's equation, experimental data can be matched by the code. From the several runs analyzed, the resulting thermal conductivity equation is lambda = 1/4.79 + 0.0247T/ + 1.06 x 10/sup -3/ exp(-1.62/kT/) - 4410. exp(-3.71/kT/) where lambda is in w/cm K, k is the Boltzman constant, and T is the temperature in Kelvin.

  18. Direct Radiative Effect and Heating Rate of black carbon aerosol: high time resolution measurements and source-identified forcing effects

    Ferrero, Luca; Mocnik, Grisa; Cogliati, Sergio; Comi, Alberto; Degni, Francesca; Di Mauro, Biagio; Colombo, Roberto; Bolzacchini, Ezio


    Black carbon (BC) absorbs sunlight in the atmosphere heating it. However, up to now, heating rate (HR) calculations from the divergence of the net radiative flux with altitude or from the modelling activity are too sparse. This work fills the aforementioned gap presenting a new methodology based on a full set of physical equations to experimentally determine both the radiative power density absorbed into a ground-based atmospheric layer (ADRE), and the consequent HR induced by the absorptive component of aerosol. In urban context, it is essentially related to the BC. The methodology is also applicable to natural components (i.e. dust) and is obtained solving the first derivative of the main radiative transfer equations. The ADRE and the consequent HR can be determined coupling spectral aerosol absorption measurements with the spectrally resolved measurements of the direct, diffuse downward radiation and the surface reflected radiance components. Moreover, the spectral absorption of BC aerosol allows its source apportionment (traffic and biomass burning (BB)) allowing the same apportionment on HR. This work reports one year of high-time resolution measurements (5 min) of sunlight absorption and HR induced by BC aerosol over Milan. A unique sampling site was set up from March 2015 with: 1) Aethalometer (AE-31, Magee Scientific, 7-λ), 2) the Multiplexer-Radiometer-Irradiometer which detects downward and reflected radiance (350-1000 nm in 3648 spectral bands) coupled with a rotating shadow-band to measure spectrally-resolved global and diffuse radiation (thus direct), 3) a meteorological station (LSI-Lastem) equipped with 3 pyranometers (global, diffuse and refrected radiation; 300-3000 nm), a thermohygrometer, a barometer, an anemometer, 4) condensation and optical particle counters (TSI 3775 and Grimm 1.107), 5) low volume sampler (FAI Hydra dual sampler, PM2.5 and PM10) for sample collection and chemistry determination. Results concerning the radiative power

  19. Performance analysis of a direct expansion air dehumidification system combined with membrane-based total heat recovery

    Liang, Cai-Hang; Zhang, Li-Zhi; Pei, Li-Xia [Key Laboratory of Enhanced Heat Transfer and Energy Conservation of Education Ministry, School of Chemistry and Chemical Engineering, South China University of Technology, Guangzhou 510640 (China)


    A direct expansion (DX) air dehumidification system is an efficient way to supply fresh and dry air to a built environment. It plays a key role in preventing the spread of respiratory disease like Swine flu (H1N1). To improve the efficiency of a conventional DX system in hot and humid regions, a new system of DX in combination with a membrane-based total heat exchanger is proposed. Air is supplied with dew points. A detailed mathematical modeling is performed. A cell-by-cell simulation technique is used to simulate its performances. A real prototype is built in our laboratory in South China University of Technology to validate the model. The effects of inlet air humidity and temperature, evaporator and condenser sizes on the system performance are investigated. The results indicate that the model can predict the system accurately. Compared to a conventional DX system, the air dehumidification rate (ADR) of the novel system is 0.5 times higher, and the coefficient of performance (COP) is 1 times higher. Furthermore, the system performs well even under harsh hot and humid weather conditions. (author)

  20. Ground coupled solar heat pumps: analysis of four options

    Andrews, J.W.


    Heat pump systems which utilize both solar energy and energy withdrawn from the ground are analyzed using a simplified procedure which optimizes the solar storage temperature on a monthly basis. Four ways of introducing collected solar energy to the system are optimized and compared. These include use of actively collected thermal input to the heat pump; use of collected solar energy to heat the load directly (two different ways); and use of a passive option to reduce the effective heating load.

  1. Waste Heat Recovery and Utilization of Copper Smelting Flash Smelting and Flash Converting Process%铜冶炼"双闪"工艺中余热回收及利用



    Based on upgrading and renovation engineering of a certain non-ferrous copper smelting process technology, the paper discusses flue gas heat waste recovery efficiency and waste heat recovery device of flash smelting furnace, flash converting furnace in copper smelting flash smelting and flash converting process, introduces waste heat utilization system, and puts forward advantages and disadvantages of the waste heat utilization system.%基于某有色铜冶炼工艺技术升级改造工程,论述了铜冶炼"双闪"工艺中闪速熔炼炉、闪速吹炼炉烟气余热回收效率及余热回收装置,介绍了余热利用系统,并指出该余热利用系统的优缺点.

  2. Shot number estimation for EB direct writing for logic LSI utilizing character-build standard-cell layout technique

    Kajiya, Yoshihiko; Nakamura, Akihiro; Yoshikawa, Masaya; Fujino, Takeshi


    Electron Beam direct writing (EBDW) technology is the most cost-effective lithography tool for small-volume logic-LSI fabrication. The EB exposure time will be greatly reduced by applying character-projection (CP) aperture. But the applicable number of CP aperture is limited to 25-400 depending upon EB lithography apparatus. The cell-based logic LSIs are composed of standard-cells (SCs) whose number is 400-1000. Therefore, it is impossible to implement all SCs as CP apertures, because the SCs are placed to 4-directions in general. We had proposed the new technique named 'Character-Build (CB) standard-cell', and demonstrate the most of the combination-logic SCs can be composed by only 17 CP apertures. In this paper, not only combination-logic SCs but also sequential-logic SCs are considered. The number of EB-shots and the chip-area are estimated for some sample circuits. Compared to the simply-limited SCs, The EB shot number is 30-40% reduced by using proposed CB standard-cell, when the CP aperture numbers are 20-30. Moreover, CB standard-cell was advantageous in the module area. Considering 2-directional placement of SCs, the combination of the EB apparatus with 50-100 CP apertures and the CB standard-cell technique may be the best method for high-speed EB direct-writing.

  3. Geothermal Resource Utilization

    Lienau, Paul J.


    Man has utilized the natural heat of the earth for centuries. Worldwide direct use of geothermal currently amounts to about 7,000 MWt, as compared to 1,500 MWe, now being used for the generation of electricity. Since the early 1970s, dwindling domestic reservoirs of oil and gas, continued price escalation of oil on the world market and environmental concerns associated with coal and nuclear energy have created a growing interest in the use of geothermal energy in the United States. The Department of Energy goals for hydrothermal resources utilization in the United States, expressed in barrels of oil equivalent, is 50 to 90 million bbl/yr by 1985 and 350 to 900 million bbl/yr by the year 2000. This relatively clean and highly versatile resource is now being used in a multitude of diverse applications (e.g., space heating and cooling, vegetable dehydration, agriculture, aquaculture, light manufacturing), and other applications requiring a reliable and economic source of heat.

  4. A Direct Heat Exchanger Unit used for Domestic Hot Water Supply in a Single-family House Supplied by Low Energy District Heating

    Brand, Marek; Thorsen, Jan Eric; Svendsen, Svend


    and 47 °C when the tap is opened. Measurements were made for control strategies using internal and external by-pass and no by-pass. Our results show the importance of keeping the branch pipe warm if comfort requirements are to be fulfilled, but this involves higher user costs for heating. To increase...

  5. 微晶无机保温材料对提高烤房热能利用率的影响%Effect of Microcrystal Inorganic Heat Preservation Material on Improving the Utilization Rate of Heat Energy of Curing Barn

    郭婷; 耿素祥; 李文; 李良勇; 彭良; 刘小斌; 余金龙


    Single factor experiment design was used to study the effect of microcrystal inorganic heat preservation material on improving the utilization rate of heat energy of curing barn, saving the cost of flue cured tobacco and improving the quality of the cured tobacco leaves. The results showed that: compared with the control, the lower cost of flue cured tobacco with adding microcrystal inorganic heat preservation material, the quality of cured tobacco leaves was good, and the quality of smoking was good; from 5 different adding thickness and proportion of processing, treatment effect of the inner wall thickness of 1.5 cm add 75% microcrystal inorganic heat preservation material was the best, the specific performance of the energy consumption was low, and the average coal consumption of 1 kg dry tobacco was 0.20 kg, and the coal saving rate was more than 14%; in terms of economic traits, the proportion of the first class tobacco leaf of cured tobacco increased by 4.6 percentage points, the average price increase of 2.0 yuan/kg(RMB) of tobacco; high quality of sensory evaluation, balanced chemical quality.%采用单因素试验设计,研究了微晶无机保温材料在提高烤房热能利用率、节约烤烟烘烤成本、提高烤后烟叶质量等方面的影响。结果表明:与对照相比,添加微晶无机保温材料烘烤成本较低,烤后烟叶等级质量好、评吸质量好;在5个不同添加厚度和比例的处理中,以内墙厚度1.5 cm 添加75%的微晶无机保温材料的处理效果最好,具体表现为能耗较低,每烘烤1 kg 干烟平均节煤0.20 kg,节煤率达14%以上;在经济性状方面,烤后烟叶的上等烟比例提高了4.6个百分点,烟叶均价平均提高2.0元/kg;感官评吸质量较高,化学品质均衡。

  6. Conceptual and direct replications fail to support the stake-likelihood hypothesis as an explanation for the interdependence of utility and likelihood judgments.

    de Molière, Laura; Harris, Adam J L


    Previous research suggests that people systematically overestimate the occurrence of both positive and negative events, compared with neutral future events, and that these biases are due to a misattribution of arousal elicited by utility (stake-likelihood hypothesis; SLH; Vosgerau, 2010). However, extant research has provided only indirect support for these arousal misattribution processes. In the present research, we initially aimed to provide a direct test of the SLH by measuring arousal with galvanic skin responses to examine the mediating role of arousal. We observed no evidence that measured arousal mediated the impact of utility on probability estimates. Given the lack of direct support for the SLH in Experiment 1, Experiments 2-5 aimed to assess the SLH by replicating some of the original findings that provided support for arousal misattribution as a mechanism. Despite our best efforts to create experimental conditions under which we would be able to demonstrate the stake-likelihood effect, we were unable to replicate previous results, with a Bayesian meta-analysis demonstrating support for the null hypothesis. We propose that accounts based on imaginability and loss function asymmetry are currently better candidate explanations for the influence of outcome utility on probability estimates.

  7. Flow visualization and void fraction measurement in liquid-metal/water direct contact heat exchange by X-ray attenuation technique

    Liu, Xin

    One concept being considered for steam generation in particular next generation nuclear reactor designs, involves water coming into direct contact with a circulating molten metal. To optimize the design of such direct contact heat exchange and vaporization systems, detailed knowledge is necessary of the various flow regimes, interfacial transport phenomena, heat transfer and operational stability. With the development of high performance digital detectors, radiography using X-rays or neutrons maybe a suitable technique to obtain information about that direct-contact interaction; i.e., void volume fractions, length scales and dynamic behavior. Under the basis of previous investigations, a complete methodology of the X-ray radiography for two-phase flow measurement has been developed from the facility and imaging analysis aspects. Through this developed methodology, a high energy X-ray imaging system is optimized for the direct-contact heat exchange experiment. Beside an on-line calibration procedure which practically quantifies the imaging system's performance, the extended linear system theory and Rose's model have also been used to evaluate the imaging system's performance, respectively. The bottleneck of the current imaging system and the future of system improvement direction have been pointed out. With our real-time, large-area high energy X-ray imaging system, the two-phase flow was visualized and stored digitally. An efficient image processing strategy has also been established by combining several optimal digital image processing algorithms. The approach has been implemented into a software computational tool written in MATLAB called T-XIP. Time-dependent heat transfer related variables, such as void fraction (void volume), local heat transfer coefficient, etc., were calculated using this software tool. Finally, an error analysis associated with the void fraction measurement has been given based on two procedures.

  8. Heat transfer 1982; Proceedings of the Seventh International Conference, Technische Universitaet Muenchen, Munich, West Germany, September 6-10, 1982. Volume 6 - General papers: Combined heat and mass transfer, particle heat transfer, heat exchangers, industrial heat transfer, heat transfer in energy utilization

    Grigull, U.; Hahne, E.; Stephan, K.; Straub, J.

    Laboratory and operational studies of heat transfer (HT) are presented. Such topics as the irreversibility of HT and mass transfer (MT), HT in disperse systems at high temperatures, fixed-bed reactors with submerged tube bundles, HT and MT in a low-speed turbulent boundary layer with condensation, multilayer insulation blankets for spacecraft applications, HT and MT in transpiration-cooled turbine blades, and finite-element analysis of HT in a solid with radiation and ablation are discussed. Contributions are included on the design of shell-and-tube heat exchangers to avoid flow-induced vibration, HT and MT in air-conditioning cooling coils, a friction-factor correlation for the offset strip-fin matrix, convective HT in gas-turbine combustion chambers, thermal-energy storage systems, turbulent buoyant HT in enclosures containing fire sources, a phase-change dry/wet cooling system for power plants, and the effect of secondary flow on HT in solar collector tubes. For individual items see A83-43014 to A83-43024

  9. 环冷机余热回收与利用系统的能量分析%Energy analysis of waste heat recovery and utilization system for ring cooler

    刘传鹏; 李国俊; 林文佺; 李明浩; 许渡姜; 郁鸿凌


    Based on the process of waste heat recovery from sintering and utilization system for ring cooler,the energy flow diagram and the energy flow diagram were draw,the relevant energy evaluation was established. The thermal bal-ance method and exergy analysis were applied to study waste heat utilization in a ring cooler,such as heat loss,energy loss,thermal efficiency and energy efficiency during the process of the conversion and utilization for waste heat resourc-es. The results show that,the thermal efficiency of ring cooler and waste heat boiler were 26.78%and 45.60%,respective-ly,the corresponding energy efficiencies were 22.88%and 45.08%,respectively,hence,ring cooler was the weak link during the recovery and utilization of waste heat system. The main factors affecting the recovery and utilization of waste heat were the air leakage of ring cooler,Un-utilization of sensible heat of the third cooling gas and the process of gas-sol-id heat transfer in sintering bed.%根据某钢厂的环冷机系统回收与利用烧结矿显热的工艺流程,绘制了能流图、(火用)流图,并建立相关能量评价指标,采用热平衡方法和(火用)分析方法对环冷机的余热回收利用状况进行研究,分析了余热资源在回收与利用过程中的热量损失、(火用)量损失、热效率与(火用)效率.结果表明:环冷机、余热锅炉2个环节的热效率分别为26.78%和45.60%,(火用)利用效率分别为22.88%和45.08%,环冷机是余热回收与利用的薄弱环节;目前影响余热回收与利用的主要因素是环冷机取热段的漏风问题、第三段冷却废气所携带的显热尚未被利用以及烧结矿层的气固换热过程.

  10. Microbial surface displayed enzymes based biofuel cell utilizing degradation products of lignocellulosic biomass for direct electrical energy.

    Fan, Shuqin; Hou, Chuantao; Liang, Bo; Feng, Ruirui; Liu, Aihua


    In this work, a bacterial surface displaying enzyme based two-compartment biofuel cell for the direct electrical energy conversion from degradation products of lignocellulosic biomass is reported. Considering that the main degradation products of the lignocellulose are glucose and xylose, xylose dehydrogenase (XDH) displayed bacteria (XDH-bacteria) and glucose dehydrogenase (GDH) displayed bacteria (GDH-bacteria) were used as anode catalysts in anode chamber with methylene blue as electron transfer mediator. While the cathode chamber was constructed with laccase/multi-walled-carbon nanotube/glassy-carbon-electrode. XDH-bacteria exhibited 1.75 times higher catalytic efficiency than GDH-bacteria. This assembled enzymatic fuel cell exhibited a high open-circuit potential of 0.80 V, acceptable stability and energy conversion efficiency. Moreover, the maximum power density of the cell could reach 53 μW cm(-2) when fueled with degradation products of corn stalk. Thus, this finding holds great potential to directly convert degradation products of biomass into electrical energy.

  11. Development Direction of Resource Utilization of Phosphogypsum%磷石膏资源化利用的发展方向

    孙志立; 车建青


    分析了目前国内磷石膏利用面临的难题和必须解决的基本问题,提出了磷石膏资源化利用的创新思路及发展方向。磷石膏制硫酸联产水泥是磷石膏资源化利用的发展方向,主要有中空长窑法、预热器窑法和窑外分解法,其中窑外分解法采用竖罐来获得高浓度窑气,并添加矿化剂,无需添加天然石膏或硫磺,可使磷石膏的利用率提高至100%。%An analysis is made of the problems facing utilization of phosphogypsum at present in China and basic problems needing to be solved , and innovation ideas and development direction for resource utilization of phosphogypsum are suggested .Production of sulfuric acid with co-production of cement from phosphogypsum is the development direction of resource utilization of phosphogypsum , the main processes are hollow long kiln method , preheater kiln method and outside kiln decomposition method, among which, outside kiln decomposition method uses vertical retort to obtain high concentrated kiln gas , and adds mineralizer , has no need to add natural gypsum or sulfur , can increase utilization ratio of phoshogypsum to 100%.

  12. Heat Harmful Mine Air Cooling and Waste Heat Utilization System Design%热害矿井空气能系统降温与废热提级利用系统设计

    邓宝; 张辉; 韩伟超; 孙永东; 姜志坡; 石银飞


    针对目前热害矿井在开采过程中存在的危害,各国针对存在热害的矿井采取了不同的防治措施,并且取得了一定效果,但是其系统的投资与运行费用较高。提出一种利用空气能系统对矿井进行降温的新模式,结合平顶山大庄矿矿井基本情况,对机电硐室进行空气能制冷降温与废热提级利用系统设计,并对主要设备进行了选型。最后与传统冷水机组制冷降温系统进行比较,空气能系统具有显著的经济效益。研究成果为企业节能减排方案的选择提供了参考和依据。%Countries having heat damage mines have adopted different prevention measures against the existing hazards in the mining process. Although some effects have been achieved, the investment and operation costs are extremely high. This paper presents a new model of using air energy system to cool the mines. Based on the general situation of Pingdingshan Dazhuang Mine, this paper designs upgraded mechanical and electrical air cooling chamber and waste heat utilization system, as well as selects the major equipment. Finally after making a comparison with conventional chiller refrigeration cooling system, it concludes that the air-source system has a significant advantage economically. The study provides a reference for energy saving and pollution reduction of the enterprises.

  13. Chemical reactions in a solar furnace 2: Direct heating of a vertical reactor in an insulated receiver. Experiments and computer simulations

    Levy, M.; Levitan, R.; Meirovitch, E.; Segal, A.; Rosin, H.; Rubin, R. (Weizmann Inst. of Science, Rehovoth (Israel))


    The performance of a solar chemical heat pipe was studied using CO{sub 2}reforming of methane as the endothermic reaction. A directly heated vertical reactor, packed with a rhodium catalyst was used. The solar tests were carried out in the Schaeffer solar furnace of the Weizmann Institute of Science. The power absorbed was up to 6.3 KW, the maximal flow rates of the gases reached 11,000 1/h, and the methane conversions reached 85%. A computer model was developed to simulate the process. Agreement of the calculations with the experimental results was quite satisfactory.

  14. Current situation and developing direction of textile waste comprehensive utilization%我国废旧纺织品综合利用现状及发展方向

    顾明明; 唐世君


    通过分析废旧纺织品综合利用现状,总结了纯棉废旧纺织品、废旧民用纺织品、废旧军服等领域综合利用的初步进展,提出了我国目前废旧纺织品综合利用存在的主要问题,明确了废旧纺织品综合利用的发展方向,即废旧纺织品综合利用必须紧紧围绕“合理规划、分类回收、技术保障、市场拓展、政策引导、舆论宣传、全社会广泛参与”的指导方针,通过长期而系统的推进,最终实现行业规范化、专业化、集约化的健康科学发展。%Based on an analysis of the current situation of textile waste comprehensive utilization, the paper summarized the initial utilization progress of cotton waste, civilian waste and military uniforms waste. The major problems in textile waste utilization were pointed out, and the developing direction of textile waste comprehensive utilization was proposed. Comprehensive utilization of textile waste must focus on "rational planning, sorting recovery, technical support, market expansion, policy guidance, media publicity and extensive public participation", so as to realize normalized, specialized, intensified scientific development of the industry.

  15. Calculation of the yearly energy performance of heating systems based on the European Building Directive and related CEN Standards

    Olesen, Bjarne W.; Langkilde, Gunnar


    and cost-effectiveness. For new and existing buildings this requires a calculation of the energy performance of the building including heating, ventilation, cooling and lighting systems, based on primary energy. Each building must have an energy certificate and regular inspections of heating, cooling...... and ventilation systems must be performed. The present paper will present the method for calculating the energy performance for heating systems. The relevant CEN-standards are presented and a sample calculation of energy performance is made for a small family house in different geographical locations: Stockholm...

  16. Impact of aerosol vertical distribution on aerosol direct radiative effect and heating rate in the Mediterranean region

    Pappas, Vasileios; Hatzianastassiou, Nikolaos; Matsoukas, Christos; Koras Carracca, Mario; Kinne, Stefan; Vardavas, Ilias


    been presented and its validity has been tested against satellite-based retrievals. A detailed spectral radiative transfer model (RTM), already used in a number of planetary and regional studies, has been used in the present study to calculate the vertically distributed aerosol direct radiative effects (DREs) and the associated aerosol heating/cooling profiles within the troposphere. Specific emphasis is given to assessment of the crucial issue of the differences between modeling the aerosol DREs using either columnar aerosol optical properties, as usually done, or vertically layered information on those properties, which is the state of the art and ideal practice. To address this problem, the following experiment has been performed: the same RTM has been used twice with the same meteorological conditions but in the first run (set1) columnar values for aerosol optical depth (AOD) have been used while using vertically distributed AOD in the second run (set2). In the second run vertically layered information for AOD is considered for 20 layers extending from the surface to 20 km a.m.s.l.. The vertical profile of AOD has been mainly based on ECHAM model. The aerosol DREs are computed at the Earth's surface, at TOA and at various levels in the atmosphere. Apart from AOD, the model also requires single-scattering albedo (SSA) and asymmetry parameter (ASY) in 18 different wavelengths, which are obtained by linear interpolation from the available wavelengths in HAC. The comparison between the obtained two sets of DRE (set1 and set2) reveal small, but notable differences which vary from one place to another. Within the atmosphere, the difference -averaged over the four seasons - ranges from -0.3 to 1.7 Wm-2 with a mean value of 0.32 Wm-2. Given the fact that the average column-integrated DREAtm values for the entire Mediterranean region based on columnar aerosol optical properties is 11.44 Wm-2, there is an average variance of 3.7 %, which locally could get to 14

  17. Polymers utilization for heating facilities

    Castex, V.; Courtois, P.; Fourniguet, M.J.; Stierlin, P. (Gaz de France (GDF), 93 - Saint-Denis (France))


    Gaz de France is involved in developing the use of new materials and in particular the use of polymers for: thermal exchangers, hot water distribution, stack pipes. The first results of Gaz de France tests in this field are presented. (author). 1 ref., 4 figs., 4 tabs.

  18. Energetic-environmental-economic assessment of the biogas system with three utilization pathways: Combined heat and power, biomethane and fuel cell.

    Wu, Bin; Zhang, Xiangping; Shang, Dawei; Bao, Di; Zhang, Suojiang; Zheng, Tao


    A typical biogas system with three utilization pathways, i.e., biogas upgrading, biogas combined heat and power (CHP), biogas solid oxide fuel cells (SOFCs) were designed. It was assessed from the viewpoint of energy, environment and economy by using energy efficiency, green degree and net present value index respectively. The assessment considered the trade-off relationships among these indexes, which is more comprehensive than previous systematic evaluation work only included single or two of the pathway(s) by using one or two of the index(es). Assessment results indicated that biogas upgrading pathway has the highest systematic energy efficiency (46.5%) and shortest payback period (8.9year) with the green degree production is the lowest (9.29gd/day). While for biogas SOFC pathway, although the green degree production is the highest (21.77gd/day), the payback period is longer (14.5year) and the energy efficiency is 13.6% lower than the biogas upgrading pathway.

  19. Outline of operation and control system and analytical investigation of transient behavior of an out-of-pile hydrogen production system for HTTR heat utilization system

    Inagaki, Yoshiyuki; Hada, Kazuhiko; Nishihara, Tetsuo; Takeda, Tetsuaki; Haga, Katsuhiro [Japan Atomic Energy Research Inst., Oarai, Ibaraki (Japan). Oarai Research Establishment; Hino, Ryutaro


    The hydrogen production system by steam reforming of natural gas is to be constructed to demonstrate effectiveness of high-temperature nuclear heat utilization systems with the HTTR. Prior to coupling of the steam reforming system with the HTTR, an out-of-pile test system is planned to investigate the system characteristics, to develop high-temperature components such as a reformer, a high-temperature isolation valve and so on, and to verify operation and control technologies and safety technology at accidents. This paper presents outline of operation and control systems and analytical review of transient behavior of the out-of-pile hydrogen production system. Main function of the operation and control systems is made not to give disturbance to the HTTR at transient state under start-up and stop operations. The operation modes are separated into two ones, namely normal and accident operation modes, and operation sequences are made for each operation mode. The normal operation sequence includes start-up, steady operation and stop of the out-of-pile system. The accident one deals with accident conditions at which supply of feed gas is stopped and helium gas is cooled passively by the steam generator. Transient behavior of the out-of-pile system was analyzed numerically according as the operation sequences. As the results, it was confirmed that the designed operation and control systems are adequate to the out-of-pile system. (author)

  20. Synthesis of an unexpected [Zn2](2+) species utilizing an MFI-type zeolite as a nano-reaction pot and its manipulation with light and heat.

    Oda, Akira; Ohkubo, Takahiro; Yumura, Takashi; Kobayashi, Hisayoshi; Kuroda, Yasushige


    Compared with mercury, the existence of [Zn2](2+) species is rare. We succeeded in preparing a stable [Zn2](2+) species by utilizing an MFI-type zeolite as a nano-reaction pot, which was confirmed using XAFS spectroscopy: the bands at R = 2.35 Å due to the Zn(+)-Zn(+) scattering and at 9660.7 eV due to the 1s-σ* (the anti-bonding orbital comprised of the 4s-4s orbital) transition of the [Zn2](2+) species. This species also gives the characteristic band around 42 000 cm(-1) due to its σ-σ* transition. Furthermore, UV-irradiation corresponding to the σ-σ* transition causes the bond dissociation, forming two unprecedented Zn(+) ions, and detached Zn(+) ions were recombined through heat-treatment at 573 K: [Zn(+)-Zn(+)] ⇄ 2Zn(+). These processes were reproduced by applying the DFT calculation method to the assumed triplet, σ(α)-σ*(α), structure formed on the M7-S2 site with the specific Al array in the MFI-type zeolite. Research into the specific field using zeolites to synthesize "ultra-state ions" is very promising.