WorldWideScience

Sample records for dioxide laser incisions

  1. Wound healing in porcine skin following low-output carbon dioxide laser irradiation of the incision

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, J.K.; Garden, J.M.; Taute, P.M.; Leibovich, S.J.; Lautenschlager, E.P.; Hartz, R.S.

    1987-06-01

    Wound healing of scalpel incisions to the depth of adipose tissue closed with conventional methods was compared with closure by low-output carbon dioxide laser irradiation. In 3 Pitman-Moore minipigs wound healing was evaluated at intervals from 1 to 90 days by the following methods: clinical variables of wound healing; formation of the basement membrane components bullous pemphigoid antigen, laminin, and fibronectin; and histological evaluation of the regeneration of the epidermis, neovascularization, and elastin and collagen formation. There was no significant difference in healing between wounds closed by the various conventional methods and by the low-output carbon dioxide laser.

  2. Quantitative evaluation of the safety of mucosal incision and submucosal dissection for colon during endoscopic submucosal dissection using carbon dioxide laser

    Science.gov (United States)

    Noguchi, Takuma; Honda, Norihiro; Hazama, Hisanao; Morita, Yoshinori; Awazu, Kunio

    2018-02-01

    Since the increase in the overall mortality rate in patients with colon cancer is remarkably high in recent years, early treatment is required. For this reason, endoscopic submucosal dissection (ESD) has been at the forefront of international attention as a low invasive treatment for early digestive cancer. In current ESD procedure, an electrosurgical knife is used for mucosal incision and subsequent submucosal dissection. However, the perforation has been reported to occur by approximately 5%. Thus, to enhance the tissue selectivity of this modality, we focused on the application of laser for ESD. A carbon dioxide laser was chosen as a surgical knife because the saline or a sodium hyaluronate solution injected into the submucosal layer in current ESD procedure has a high absorption coefficient at the wavelength of the carbon dioxide laser. In this research, ex vivo experiment was performed at the output power of 3-7 W and discuss the optimum irradiation power of laser. As a result of ex vivo experiment using extracted porcine colon tissues, mucosal incision and submucosal dissection were safely and less invasively performed in every output power, without reaching the thermal damage to a muscular layer. This is because a carbon dioxide laser is strongly absorbed by saline injected into submucosa. ESD using a carbon dioxide laser is a safer method for the treatment of early colon cancer. We are planning to measure and compare the optical and thermal properties of porcine colon with those of human colon.

  3. Comparison of first-intention healing of carbon dioxide laser, 4.0-MHz radiosurgery, and scalpel incisions in ball pythons (Python regius).

    Science.gov (United States)

    Hodshon, Rebecca T; Sura, Patricia A; Schumacher, Juergen P; Odoi, Agricola; Steeil, James C; Newkirk, Kim M

    2013-03-01

    To evaluate first-intention healing of CO(2) laser, 4.0-MHz radiowave radiosurgery (RWRS), and scalpel incisions in ball pythons (Python regius). 6 healthy adult ball pythons. A skin biopsy sample was collected, and 2-cm skin incisions (4/modality) were made in each snake under anesthesia and closed with surgical staples on day 0. Incision sites were grossly evaluated and scored daily. One skin biopsy sample per incision type per snake was obtained on days 2, 7, 14, and 30. Necrotic and fibroplastic tissue was measured in histologic sections; samples were assessed and scored for total inflammation, histologic response (based on the measurement of necrotic and fibroplastic tissues and total inflammation score), and other variables. Frequency distributions of gross and histologic variables associated with wound healing were calculated. Gross wound scores were significantly greater (indicating greater separation of wound edges) for laser incisions than for RWRS and scalpel incisions at all evaluated time points. Necrosis was significantly greater in laser and RWRS incisions than in scalpel incision sites on days 2 and 14 and days 2 and 7, respectively; fibroplasia was significantly greater in laser than in scalpel incision sites on day 30. Histologic response scores were significantly lower for scalpel than for other incision modalities on days 2, 14, and 30. In snakes, skin incisions made with a scalpel generally had less necrotic tissue than did CO(2) laser and RWRS incisions. Comparison of the 3 modalities on the basis of histologic response scores indicated that use of a scalpel was preferable, followed by RWRS and then laser.

  4. Carbon dioxide laser for de-epithelialization of periodontal flaps.

    Science.gov (United States)

    Centty, I G; Blank, L W; Levy, B A; Romberg, E; Barnes, D M

    1997-08-01

    Regeneration of mineralized and soft connective tissue components of the attachment apparatus is the main goal in the treatment of periodontal diseases. Often, apical migration of epithelium (long junctional epithelium) effectively prevents the formation of bone and connective tissue attachment after periodontal surgery. The purpose of the present study was to compare conventional periodontal surgery combined with carbon dioxide laser and conventional periodontal surgery alone with respect to epithelial elimination and degree of necrosis of mucoperiosteal flaps. After signing a consent form, five patients with at least two comparable bilateral periodontal defects needing pocket elimination surgery participated in this study. The investigators randomly divided each side into test and control sites. Each patient received oral hygiene instruction and initial therapy prior to surgery. At surgery, the test site received a sulcular incision and carbon dioxide laser de-epithelialization of the outer and inner aspects of the flap. The control group received reverse bevel incision only. The surgeon performed open flap debridement on all teeth. At the time of surgery, the surgeon did a biopsy of each site and submitted specimens for histologic evaluation. A matched pairs t-test was used to analyze the data. The results show significant differences between the carbon dioxide laser and reverse bevel incision with respect to sulcular (P test sites, with a predominance of plasma cells. Lining the sulcular and gingival (external) lased areas, investigators found coagulation necrosis covered by fibrin and coagulated blood. The laser appears to effectively remove epithelium at the time of surgery; however, future long-term, well-controlled quantitative histologic studies are needed to evaluate the effect of repeated carbon dioxide laser de-epithelialization of the gingival (external) surface of mucoperiosteal flaps at intervals during the healing period.

  5. Carbon dioxide (CO2) laser treatment of cutaneous papillomas in a common snapping turtle, Chelydra serpentina.

    Science.gov (United States)

    Raiti, Paul

    2008-06-01

    Carbon dioxide (CO2) laser was used to treat multiple cutaneous papillomas on an adult female common snapping turtle, Chelydra serpentina serpentina. A combination of excisional and ablative techniques provided excellent intraoperative visibility and postoperative results due to the laser's unique ability to incise and vaporize soft tissue.

  6. Penetrating and Intrastromal Corneal Arcuate Incisions in Rabbit and Human Cadaver Eyes: Manual Diamond Blade and Femtosecond Laser-Created Incisions.

    Science.gov (United States)

    Gray, Brad; Binder, Perry S; Huang, Ling C; Hill, Jim; Salvador-Silva, Mercedes; Gwon, Arlene

    2016-07-01

    To compare morphologic differences between freehand diamond or femtosecond laser-assisted penetrating and intrastromal arcuate incisions. Freehand diamond blade, corneal arcuate incisions (180° apart, 60° arc lengths) and 150 kHz femtosecond laser (80% scheimpflug pachymetry depth corneal thickness) arcuate incisions were performed in rabbits. Intrastromal arcuate incisions (100 μm above Descemet's membrane, 100 μm below epithelium) were performed in rabbit corneas (energy 1.2 μJ, spot line separation 3 × 3 μm, 90° side cut angle). Eyes were examined by slit lamp and light microscopy up to 47 days post-procedure. Freehand diamond blade penetrating incisions, and femtosecond laser penetrating and intrastromal arcuate incisions (energy 1.8 μJ, spot line separation 2 × 2 μm) were performed in cadaver eyes. Optical coherence tomography was performed immediately after surgery and the corneas were fixed for light scanning and transmission electron microscopy. The rabbit model showed anterior stromal inflammation with epithelial hyperplasia in penetrating blade and laser penetrating wounds. The laser intrastromal and penetrating incisions showed localized constriction of the stromal layers of the cornea near the wound. In cadaver eyes, penetrating wound morphology was similar between blade and laser whereas intrastromal wounds did not affect the cornea above or below incisions. Penetrating femtosecond laser arcuate incisions have more predictable and controlled outcomes shown by less post-operative scarring than incisions performed with a diamond blade. Intrastromal incisions do not affect uncut corneal layers as demonstrated by histopathology. The femtosecond laser has significant advantages in its ability to make intrastromal incisions which are not achievable by traditional freehand or mechanical diamond blades.

  7. Complications of femtosecond laser corneal small incision lenticule extraction

    Directory of Open Access Journals (Sweden)

    Qing-Hong Lin

    2017-07-01

    Full Text Available AIM:To investigate the safety and complications of femtosecond laser corneal small incision lenticule extraction(SMILEprocedure and discuss the prevention and treatment.METHODS: We retrospectively studied the complications of 403 patients(799 eyeswith myopia and myopic astigmatism treated by SMILE.RESULTS: All the patients underwent the operation successfully. Only 1 case(1 eyesuffered from dark spot and changed to femtosecond laser-assisted LASIK(FS-LASIK, 5 cases(5 eyes, 0.6%suffered from the suction loss, 11 cases(17 eyes, 2.1%developed opaque bubble layer. All patients gained perfect uncorrected visual acuity(UCVA(20/20. The best corrected visual acuity(BCVAdid not decrease after operations. The incidence of haze and diffuse lamellar keratitis was low(0.3% and 0.4%, respectivelyand no other complications were observed. There was 9 eyes in 6 patients(1.1%found regression of refraction at 6mo after surgery, while the UCVA of rest patients reached 1.0 at 3mo after surgery.CONCLUSION: The SMILE procedure has high safety for myopia and myopic astigmatism. Effective prevention and management of the complications is the key to achieve the satisfactory visual acuity.

  8. Efficiency of soft tissue incision with a novel 445-nm semiconductor laser.

    Science.gov (United States)

    Braun, Andreas; Kettner, Moritz; Berthold, Michael; Wenzler, Johannes-Simon; Heymann, Paul Günther Baptist; Frankenberger, Roland

    2018-01-01

    Using a 445-nm semiconductor laser for tissue incision, an effective cut is expected due to the special absorption properties of blue laser light in soft tissues. The aim of the present study was the histological evaluation of tissue samples after incision with a 445-nm diode laser. Forty soft tissue specimens were obtained from pork oral mucosa and mounted on a motorized linear translation stage. The handpiece of a high-frequency surgery device, a 970-nm semiconductor laser, and a 445-nm semiconductor laser were connected to the slide, allowing a constant linear movement (2 mm/s) and the same distance of the working tip to the soft tissue's surface. Four incisions were made each: (I) 970-nm laser with conditioned fiber tip, contact mode at 3-W cw; (II-III): 445-nm laser with non-conditioned fiber tip, contact mode at 2-W cw, and non-contact mode (1 mm) at 2 W; and (IV): high-frequency surgery device with straight working tip, 90° angulation, contact mode at 50 W. Histological analysis was performed after H&E staining of the embedded specimens at 35-fold magnification. The comparison of the incision depths showed a significant difference depending on the laser wavelength and the selected laser parameters. The highest incision depth was achieved with the 445-nm laser contact mode (median depth 0.61 mm, min 0.26, max 1.17, interquartile range 0.58) (p laser, a higher cutting efficiency can be expected when compared with a 970-nm diode laser and high-frequency surgery. Even the 445-nm laser application in non-contact mode shows clinically acceptable incision depths without signs of extensive soft tissue denaturation.

  9. Laser incising of wood: Impregnation of columns with water-soluble dye

    International Nuclear Information System (INIS)

    Hattori, N.; Ando, K.; Kitayama, S.; Nakamura, Y.

    1994-01-01

    To know whether or not laser incising is a useful pre-treatment technique in impregnating a chemical fluid into lumber, pin holes were made in columns of hinoki (Chamaecyparis obtusa Endl.), sugi (Cryptomeria japonica D. Don), karamatsu (Larix leptolepis Gordon) and douglas-fir (Pseudo-tsuga menziesii Franco) with 1.7 kW CO2 laser, and a water-soluble dye was impregnated into these columns with a local pressure impregnation device. Retentions, and lengths and widths of penetrations from each hole were measured quantitatively. Referring to the results of the preparatory experiment mentioned above, incising patterns for sugi and douglas-fir were designed, and the same water-soluble dye was impregnated into the laser-incised columns as well as into non-incised ones with the vacuum-pressure method to obtain penetrated layers with the target depths completely. As a result, a retention of 200 kg/m3 of dye could be achieved for a column of douglas-fir even if it is a species difficult to impregnate. The penetrated layer also could be formed completely at the depth of the laser incision. Therefore, it is concluded that laser incising can be used for the pre-treatment before impregnation of wood columns. (author)

  10. In vitro conjunctival incision repair by temperature-controlled laser soldering.

    Science.gov (United States)

    Norman, Galia; Rabi, Yaron; Assia, Ehud; Katzir, Abraham

    2009-01-01

    The common method of closing conjunctival incisions is by suturing, which is associated with several disadvantages. It requires skill to apply and does not always provide a watertight closure, which is required in some operations (e.g., glaucoma filtration). The purpose of the present study was to evaluate laser soldering as an alternative method for closing conjunctival incisions. Conjunctival incisions of 20 ex vivo porcine eyes were laser soldered using a temperature-controlled fiberoptic laser system and an albumin mixed with indocyanine green as a solder. The control group consisted of five repaired incisions by a 10-0 nylon running suture. The leak pressure of the repaired incisions was measured. The mean leak pressure in the laser-soldered group was 132 mm Hg compared to 4 mm Hg in the sutured group. There was no statistically significant difference in both the incision's length and distance from the limbus between the groups, before and after the procedure, indicating that there was no severe thermal damage. These preliminary results clearly demonstrate that laser soldering may be a useful method for achieving an immediate watertight conjunctival wound closure. This procedure is faster and easier to apply than suturing.

  11. Temperature-controlled laser-soldering system and its clinical application for bonding skin incisions

    Science.gov (United States)

    Simhon, David; Gabay, Ilan; Shpolyansky, Gregory; Vasilyev, Tamar; Nur, Israel; Meidler, Roberto; Hatoum, Ossama Abu; Katzir, Abraham; Hashmonai, Moshe; Kopelman, Doron

    2015-12-01

    Laser tissue soldering is a method of repairing incisions. It involves the application of a biological solder to the approximated edges of the incision and heating it with a laser beam. A pilot clinical study was carried out on 10 patients who underwent laparoscopic cholecystectomy. Of the four abdominal incisions in each patient, two were sutured and two were laser soldered. Cicatrization, esthetical appearance, degree of pain, and pruritus in the incisions were examined on postoperative days 1, 7, and 30. The soldered wounds were watertight and healed well, with no discharge from these wounds or infection. The total closure time was equal in both methods, but the net soldering time was much shorter than suturing. There was no difference between the two types of wound closure with respect to the pain and pruritus on a follow-up of one month. Esthetically, the soldered incisions were estimated as good as the sutured ones. The present study confirmed that temperature-controlled laser soldering of human skin incisions is clinically feasible, and the results obtained were at least equivalent to those of standard suturing.

  12. Femtosecond laser refractive surgery: small-incision lenticule extraction vs. femtosecond laser-assisted LASIK.

    Science.gov (United States)

    Lee, Jimmy K; Chuck, Roy S; Park, Choul Yong

    2015-07-01

    Small-incision lenticule extraction (SMILE) is a novel technique devised to correct refractive errors. SMILE circumvents excimer laser photoablation of cornea, as the stromal lenticule cut by femtosecond laser is removed manually. Smaller incisions and preservation of anterior corneal biomechanical strength have been suggested as some of the advantages of SMILE over femtosecond laser-assisted LASIK (FS-LASIK). In this review, we compared previous published results of SMILE and FS-LASIK. The advantage, efficacy and safety of SMILE are compared with FS-LASIK. SMILE achieved similar efficacy, predictability and safety as FS-LASIK. Greater preservations of corneal biomechanical strength and corneal nerves were observed in SMILE when compared with LASIK or PRK. Additionally, the incidence of postoperative dry eye syndrome was found to be less problematic in SMILE than in FS-LASIK. SMILE is a promising new surgery for refractive error correction. Prospective and retrospective studies of SMILE have shown that results of SMILE are similar to FS-LASIK. With advances in femtosecond laser technology, SMILE may gain greater acceptance in the future.

  13. Femtosecond laser effect on the self-sealing properties of the corneal incision of various lengths and profile (experimental trial

    Directory of Open Access Journals (Sweden)

    Yulduz Shavkatovna Nizametdinova

    2015-06-01

    Full Text Available An experimental investigation was carried out to study self-sealing properties of corneal incisions of different profile and length carried out with femtosecond laser Victus (Technolas Perfect Vision/Bausch&Lomb. Using femtosecond laser for this purpose allows creating corneal incisions of high precision and predictability. Reproducibility and standardization of the incision profile and length are an advantage of this technology. Obtained results showed that single-profile incisions are less stable and safe when compared to multi-profile ones. It was noted that incision length increase promotes its self-sealing properties.

  14. Femtosecond laser based small incision lenticule extraction for moderate and high myopia

    DEFF Research Database (Denmark)

    Hjortdal, Jesper Østergaard; Asp, Sven; Ivarsen, Anders

    Femtosecond laser based small incision lenticule extraction for moderate and high myopia. Jesper Hjortdal, Sven Asp, Anders Ivarsen, Anders Vestergaard Department of Ophthalmology, Aarhus University Hospital, Denmark Purpose: ReLEx® smile is a new keratorefractive procedure whereby a stromal lent....... Refractive predictability, safety and patient satisfaction at 3 months seems equal to ReLEx flex and FS-LASIK. Optimizing laser energy settings and surgeon experience is important to minimize initial inferior results....

  15. Nd:YAG laser incision of the vesical neck in obstructive BPH

    Science.gov (United States)

    Gilbert, Peter T. O.

    2003-06-01

    From February, 1995 through June, 2002, 68 patients underwent laser incision of the prostate at our clinic. By means of a 23 F cytoscope and a 600 micrometer lateral firing quartz fiber the vesical neck was incised at the 5 and 7 o'clock position at 60 W power. Total energy averaged 13648 J. Operative time did not exceed 15 minutes. General anesthesia was employed in all but one patient. 38 patients remained catheter-free whereas 30 patients were catheterized for two hours. Except for three cases, all patients were discharged on the same day, usually after the first micturition. Anti-inflammatory treatment was administered for two weeks, Cotrimoxazole for 5 days. No serious complications were encountered. Minor side effects included urinary retention (1 pat.), urinary infection (3 pat.) and retrograde ejaculation (1 pat.). Considering a mean follow-up of 21 months, the average Qmax improved enormously (25.4 ml/s versus 10.9 ml/s), as did residual urine volume (35 ml versus 95 ml) and IPSS (7.1 versus 20.5). Three patients required TUR-P 2-3 years after laser surgery and one patient underwent radical retropubic prostatectomy for prostate cancer 2 years later. In conclusion, Nd:YAG laser incision of the prostate is a simple, safe, reliable and cost-effective outpatient procedure.

  16. Corneal tissue welding with infrared laser irradiation after clear corneal incision.

    Science.gov (United States)

    Rasier, Rfat; Ozeren, Mediha; Artunay, Ozgür; Bahçecioğlu, Halil; Seçkin, Ismail; Kalaycoğlu, Hamit; Kurt, Adnan; Sennaroğlu, Alphan; Gülsoy, Murat

    2010-09-01

    The aim of this study was to investigate the potential of infrared lasers for corneal welding to seal corneal cuts done in an experimental animal model. Full-thickness corneal cuts on freshly enucleated bovine eyes were irradiated with infrared (809-nm diode, 980-nm diode, 1070-nm YLF, and 1980-nm Tm:YAP) lasers to get immediate laser welding. An 809-nm laser was used with the topical application of indocyanine green to enhance the photothermal interaction at the weld site. In total, 60 bovine eyes were used in this study; 40 eyes were used in the first part of the study for the determination of optimal welding parameters (15 eyes were excluded because of macroscopic carbonization, opacification, or corneal shrinkage; 2 eyes were used for control), and 20 eyes were used for further investigation of more promising lasers (YLF and Tm:YAP). Laser wavelength, irradiating power, exposure time, and spot size were the dose parameters, and optimal dose for immediate closure with minimal thermal damage was estimated through histological examination of welded samples. In the first part of the study, results showed that none of the applications was satisfactory. Full-thickness success rates were 28% (2 of 7) for 809-nm and for 980-nm diode lasers and 67% (2 of 3) for 1070-nm YLF and (4 of 6) for 1980-nm Tm:YAP lasers. In the second part of the study, YLF and Tm:YAP lasers were investigated with bigger sample size. Results were not conclusive but promising again. Five corneal incisions were full-thickness welded out of 10 corneas with 1070-nm laser, and 4 corneal incisions were partially welded out of 10 corneas with 1980-nm laser in the second part of the study. Results showed that noteworthy corneal welding could be obtained with 1070-nm YLF laser and 1980-nm Tm:YAP laser wavelengths. Furthermore, in vitro and in vivo studies will shed light on the potential usage of corneal laser welding technique.

  17. Carbon dioxide laser resurfacing of rhytides and photodamaged skin

    OpenAIRE

    Kelly, KM; Nelson, JS

    1998-01-01

    Carbon dioxide (CO 2 ) laser resurfacing has been used as a method to treat rhytides and photodamaged skin. This laser offers several advantages over previously utilised modalities but its use has several inherent risks. This article will review important aspects of CO 2 laser resurfacing including laser-skin interactions, patient selection, effective pre- and post-operative regimens and potential complications.

  18. Small incision lenticule extraction (SMILE) and femtosecond laser LASIK: comparison of corneal wound healing and inflammation

    Science.gov (United States)

    Dong, Zixian; Zhou, Xingtao; Wu, Jihong; Zhang, Zhehuan; Li, Tao; Zhou, Zimei; Zhang, Shenghai; Li, Gang

    2014-01-01

    Aim To evaluate and compare early corneal wound healing and inflammatory responses after small incision lenticule extraction (SMILE) versus femtosecond laser laser in situ keratomileusis (LASIK). Methods Thirty-six eyes of 36 rabbits underwent SMILE, while another 36 eyes of 36 rabbits were treated with femtosecond laser LASIK. All the eyes were subjected to the same refractive correction of −6.00 DS/−1.00 DC. Twelve eyes that had no surgery were included for control. After euthanisation, corneal tissue sections were evaluated with terminal deoxyribonucleotidyl transferase-mediated dUTP-digoxigenin nick-end labelling (TUNEL) assay to detect apoptosis at postoperative 4 and 24 h, immunocytochemistry for Ki67 to detect keratocyte proliferation at postoperative day 3, week 1 and month 1, and immunocytochemistry for CD11b to detect inflammation at postoperative day 1, day 3 and week 1, respectively. Results No adverse effects were noted after SMILE or LASIK. Corneal healing postoperatively was uneventful in all cases. There were significantly fewer TUNEL-positive corneal stromal cells after the SMILE procedure at 4 and 24 h postoperatively (pLASIK procedure. In addition, immunocytochemistry showed significantly fewer Ki67-positive cells in the SMILE group than those in the femtosecond laser LASIK group at day 3 and week 1 postoperatively (pLASIK. PMID:24227802

  19. A Carbon Dioxide Laser Bibliography, 1964-1969,

    Science.gov (United States)

    A bibliography concerning carbon dioxide lasers has been compiled covering the period 1964 through 1969. The chronologically listed references have also been catalogued into an author index and a subject index. (Author)

  20. CO2 temperature-controlled laser soldering of pig trachea incisions in vitro using flexible albumin bands

    Science.gov (United States)

    Sharvit, Dan; Vasilyev, Tamar; Vasserman, Irena; Simhon, David; Kariv, Naam; DeRowe, Ari; Katzir, Abraham

    2005-04-01

    Resection of a segment of the trachea is a procedure applied for the removal of cervical tumors invading the trachea, or for the treatment of severe tracheal stenosis. The current method of anastomosis is based on multiple sutures. The main drawbacks of this method are: 1) A long procedure time, 2) An air leakage, and 3) An inflammatory response to the sutures. In this study we evaluated the feasibility and effectiveness of the use of temperature controlled CO2 laser soldering of incisions in pig tracheas in vitro. A transverse incision was made in a separated pig trachea. A flexible albumin band was prepared and was laser soldered with albumin solder to the outer surface of the trachea, covering the incision. The soldered trachea ends were sealed and the burst pressure was measured. In a series of in vitro experiments, the mean burst pressure was found to be 230 mm Hg. These preliminary results demonstrated that laser soldering using a flexible albumin band may be a useful method for sealing an incision in the trachea.

  1. Analysis on incidence and management of complications after femtosecond laser-assisted small incision lenticule extraction

    Directory of Open Access Journals (Sweden)

    Cai-Hong Li

    2018-04-01

    Full Text Available AIM: To evaluate the safety and postoperative complications of femtosecond laser-assisted small incision lenticule extraction(SMILE. METHODS: Retrospective case series. A total of 1127 patients(2 236 eyeswho were treated with SMILE for myopia or myopia astigmatism between June 2016 and May 2017 were enrolled in this study. Eyes that developed postoperative complications were noted and identified. The incidence, risk factors, management and prognosis were analyzed. The follow-up was 6mo.RESULTS: The rate of postoperative complications was 8.05%, included diffuse lamellar keratitis(3.31%, delayed visual acuity(2.59%, minor interface residue(0.63%, and ghost images(1.52%. These complications had an impact on best corrected visual acuity(BCVAat 3mo in only 1 eye with decentered ablation and was re-treated with topography-guided laser-assisted subepithelial keratomileusis(LASEK. Good visual outcomes were achieved in all eyes finally. CONCLUSION: Although few eyes suffered postoperative complications, SMILE is an acceptable safe surgery. Careful surgical skill, appropriate surgical parameter, and rational postoperative medication can decrease the risk of complication.

  2. Histological Study of Induced Incisions on Rabbits’ Tongues with Three Diode Lasers with Different Wavelengths in Continuous Mode

    Directory of Open Access Journals (Sweden)

    Salwa Yammine

    2018-01-01

    Full Text Available Objective. Diode lasers have multiple indications in everyday dental practice. They allow carrying out incisions, coagulation of soft tissue, and Low-Level Laser Therapy. The goal of this study is to compare histologically the tissue interaction zones and edges of an induced laser incision on rabbits’ tongues with three different wavelengths of 810, 940, and 980 nm in continuous mode. Methods. Fourteen male rabbits were divided into six groups. Each animal underwent three incisions of 10 mm length on the right ventral face of the tongue, carried out in continuous mode with three diode lasers with different wavelengths of 810, 940, and 980 nm. Rabbits were sacrificed at 0, 1, 2, 6, and 15 hours and 14 days. Five rabbits were sacrificed at 0 hours and 2 hours and one rabbit was sacrificed at 1, 6, and 15 hours and at 14 days. The appearance of neutrophils marked the onset time of the inflammatory reaction. Histological study of the incisions was chosen to evaluate the edges and to measure the depth and width of carbonization and necrotic and inflammatory zones. Healing was evaluated at 14 days. Friedman test was used to assess statistical differences between groups. Results. In the experimental adopted conditions, the carbonization zone was marked by degradation of vacuoles and an elongation of nuclei and was observed on the edges of incisions. Carbonization and necrotic and inflammatory zones were measured for rabbits sacrificed at 0, 1, 2, 6, and 15 hours but the onset of inflammation zone marked by the infiltration of neutrophils did not appear before 6 hours. The neutrophils infiltration was higher at 15 hours than at 6 hours. Complete healing was shown at 14 days. According to the time for the regularity of the edges, the interpretation was qualitative without a statistical test. The statistical analysis of the three different diode lasers in this study showed nonsignificant difference between the different groups for the depth (p=0

  3. High-energy, short-pulse, carbon-dioxide lasers

    International Nuclear Information System (INIS)

    Fenstermacher, C.A.

    1979-01-01

    Lasers for fusion application represent a special class of short-pulse generators; not only must they generate extremely short temporal pulses of high quality, but they must do this at ultra-high powers and satisfy other stringent requirements by this application. This paper presents the status of the research and development of carbon-dioxide laser systems at the Los Alamos Scientific Laboratory, vis-a-vis the fusion requirements

  4. RHEED study of titanium dioxide with pulsed laser deposition

    DEFF Research Database (Denmark)

    Rasmussen, Inge Lise; Pryds, Nini; Schou, Jørgen

    2009-01-01

    Reflection high-energy electron diffraction (RHEED) operated at high pressure has been used to monitor the growth of thin films of titanium dioxide (TiO2) on (1 0 0) magnesium oxide (MgO) substrates by pulsed laser deposition (PLD). The deposition is performed with a synthetic rutile TiO2 target...

  5. High-power diode laser in the circumvestibular incision for Le Fort I osteotomy in orthognathic surgery: a prospective case series study.

    Science.gov (United States)

    Jaeger, Filipe; Chiavaioli, Gustavo Marques; de Toledo, Guilherme Lacerda; Freire-Maia, Belini; Amaral, Marcio Bruno Figueiredo; Mesquita, Ricardo Alves

    2018-01-01

    The incisions during orthognathic surgery are classically performed with conventional scalpel or electrocautery. Considering that the high-power diode laser surgery may provide advantages when compared to conventional incision techniques, the current study aimed to present a prospective case series of patients submitted to circumvestibular incision for Le Fort I osteotomy. Ten patients with dentofacial deformities who underwent to rapid assisted maxillary expansion or bimaxillary orthognathic surgery were enrolled in the study. All incisions were performed by a single surgeon using an 808-nm diode laser, with an optical fiber of 600 μm, at a power of 2.5 W, in a continuous-wave mode. The performance of the incision was evaluated by incision velocity, bleeding, edema, secondary infection, clinical healing, and pain. The velocity of the incision ranged from 0.10 to 0.20 mm/s (mean 0.13 ± 0.03 mm/s). Considering bleeding during the soft tissue incision, all surgeries were classified as absent bleeding. All patients presented a clinical healing of the surgical wound in a period that range from 3 to 5 weeks and experienced swelling during the follow-up period. On average, approximately 50% of the swelling had resolved after the third postoperative week, and 28.8% of swelling remained after 2 months after the surgery. The pain decreased after 2 and 3 days, and 90.0% of the patients reported no pain after 7 postoperative days. High-power diode laser is effective and safety during circumvestibular incisions for Le Fort I osteotomy in orthognathic surgery decreasing bleeding, surgery time, pain, and edema after orthognathic surgery.

  6. Sequential treatment with intradermal incision (intracision) and 2,940-nm Er:YAG laser for chicken pox scars.

    Science.gov (United States)

    Lee, Sang Ju; Kim, Young Koo; Choi, Sun Young; Park, Kui Young; Seo, Seong Jun

    2014-01-01

    Boxcar scars, such as chicken pox scars, are round to oval depressions with sharply defined vertical edges. Subcision is a simple and safe procedure for treatment of atrophic and depressed scars, but boxcar scars are generally not eliminated by subcision. Intradermal incision technique (intracision) can treat chicken pox scars by untethering fibrotic strands, raising collagen synthesis, and having additional intradermal blood pocket formation. We have found that chicken pox scars further improve when intracision is followed by laser skin resurfacing. © 2013 Wiley Periodicals, Inc.

  7. Efficiency of Carbon Dioxide Fractional Laser in Skin Resurfacing.

    Science.gov (United States)

    Petrov, Andrej

    2016-06-15

    The aim of the study was to confirm the efficiency and safety of the fractional CO2 laser in skin renewal and to check the possibility of having a synergistic effect in patients who besides carbon dioxide laser are treated with PRP (platelet-rich plasma) too. The first group (Examined Group 1 or EG1) included 107 patients treated with fractional CO2 laser (Lutronic eCO2) as mono-therapy. The second group (Control Group or CG) covered 100 patients treated with neither laser nor plasma in the same period but subjected to local therapy with drugs or other physio-procedures under the existing protocols for treatment of certain diseases. The third group (Examined Group 2 or EG2) treated 25 patients with combined therapy of CO2 laser and PRP in the treatment of facial rejuvenation or treatment of acne scars. Patient's satisfaction, in general, is significantly greater in both examined groups (EG1 and EG2) (p skin is significant (χ2 = 39.41; df = 4; p skin was significantly lower in examined group (treated with laser), p = 0.0002. Multifunctional fractional carbon dioxide laser used in treatment of patients with acne and pigmentation from acne, as well as in the treatment of scars from different backgrounds, is an effective and safe method that causes statistically significant better effect of the treatment, greater patients' satisfaction, minimal side effects and statistically better response to the therapy, according to assessments by the patient and the therapist.

  8. Modelling channel incision and alpine hillslope development using laser altimetry data

    NARCIS (Netherlands)

    Anders, N.S.; Seijmonsbergen, A.C.; Bouten, W.

    2009-01-01

    This paper presents a new approach to simulate drainage basin evolution and demonstrates that high resolution elevation data can be used as useful tool for a dynamic simulation of Alpine landscape development, in which channel incision is incorporated in high spatial detail. A vector channel

  9. Solar pumped continuous wave carbon dioxide laser

    Science.gov (United States)

    Yesil, O.; Christiansen, W. H.

    1978-01-01

    In an effort to demonstrate the feasibility of a solar pumped laser concept, gain has been measured in a CO2-He laser medium optically pumped by blackbody radiation. Various gas mixtures of CO2 and He have been pumped by blackbody radiation emitted from an electrically heated oven. Using a CO2 laser as a probe, an optical gain coefficient of 1.8 x 10 to the -3rd/cm has been measured at 10.6 microns for a 9:1 CO2-He mixture at an oven temperature of about 1500 K, a gas temperature of about 400 K and a pressure of about 1 torr. This corresponds to a small signal gain coefficient when allowance is made for saturation effects due to the probe beam, in reasonable agreement with a theoretical value.

  10. Ex vivo evaluation of femtosecond pulse laser incision of urinary tract tissue in a liquid environment: implications for endoscopic treatment of benign ureteral strictures.

    Science.gov (United States)

    Liang, Jun-Hao; Kang, Jian; Pan, Yu-Long; Zhang, Liang; Qi, Jun

    2011-08-01

    The femtosecond (FS) pulse laser incises soft tissues with minimal peripheral damage and is a promising cutting tool for ureteroscopic endoureterotomy of benign ureteral strictures. To evaluate the feasibility of applying the FS laser to ureteroscopic endoureterotomy. A commercial Ti:Sapphire regenerative amplifier system (Coherent, RegA 9050, USA) was used in this study. Normal saline, 5% glucose solution, 4% mannitol solution, distilled water, and a 1% (v/v) suspension of whole blood with each of these solutions were tested for their attenuation rate (AR) of the FS laser's power. Bladder specimens from Sprague-Dawley (SD) rats were used as a surrogate model. The laser incised slots of 2 mm in length at bladder samples using three power grades (5×, 10×, and 20× the threshold power) combined with five effective pulse rates (40, 20, 10, 5, and 2.5 kHz), both in air and in normal saline. After samples were processed with standard hematoxylin-eosin staining procedures, the incision depth and collateral damage range were determined microscopically. The ARs of blood suspensions with each of the three isosmotic solutions were significantly higher than the other five solutions (P laser's cutting depth and the collateral damage were increased with the laser power or power density but the collateral damages were less than 100 µm. Microbubble formation was detected in the liquid environments tested and influenced the effective laser power. Endoscopic application of the FS laser is feasible. Microbubble formation with the laser incision, however, may influence cutting effects. Proposed methods to address these issues include increasing the irrigation rate, using distilled water as irrigation or using gas insufflation instead of irrigation. It is necessary to evaluate these methods, as well as the long-term biologic response to laser incision, on living animal models in endoscopic settings before use on humans. Copyright © 2011 Wiley-Liss, Inc.

  11. Comparison of CO(2) laser and 4.0 MHz radiosurgery for making incisions in the skin and muscles of green iguanas (Iguana iguana).

    Science.gov (United States)

    Hernández-Divers, S J; Stahl, S J; Rakich, P M; Blas-Machado, U

    2009-01-03

    Four green iguanas scheduled for euthanasia were used to compare the extent of collateral tissue damage associated with CO(2) laser and 4.0 MHz radiosurgery. The iguanas were anaesthetised and a series of three skin and three muscle incisions was made by 4.0 MHz radiosurgery (0.18 mm wire electrode, 25 W, cut mode) and CO(2) laser (0.3 mm ceramic tip, 15 W focused beam super-pulse mode), and three incisions were made with a scalpel blade as controls. Following euthanasia, a total of 60 skin and 36 muscle sections were evaluated histologically. Radiosurgery and the laser both produced bloodless incisions, but radiosurgery caused significantly less collateral tissue damage in the skin (307 [97] v 386 [108] microm) and the muscle (18 [7] v 91 [15] microm).

  12. Efficiency of Carbon Dioxide Fractional Laser in Skin Resurfacing

    Directory of Open Access Journals (Sweden)

    Andrej Petrov

    2016-05-01

    CONCLUSION: Multifunctional fractional carbon dioxide laser used in treatment of patients with acne and pigmentation from acne, as well as in the treatment of scars from different backgrounds, is an effective and safe method that causes statistically significant better effect of the treatment, greater patients’ satisfaction, minimal side effects and statistically better response to the therapy, according to assessments by the patient and the therapist.

  13. Vector analysis of high (≥3 diopters) astigmatism correction using small-incision lenticule extraction and laser in situ keratomileusis.

    Science.gov (United States)

    Chan, Tommy C Y; Wang, Yan; Ng, Alex L K; Zhang, Jiamei; Yu, Marco C Y; Jhanji, Vishal; Cheng, George P M

    2018-06-13

    To compare the astigmatic correction in high myopic astigmatism between small-incision lenticule extraction and laser in situ keratomileusis (LASIK) using vector analysis. Hong Kong Laser Eye Center, Hong Kong. Retrospective case series. Patients who had correction of myopic astigmatism of 3.0 diopters (D) or more and had either small-incision lenticule extraction or femtosecond laser-assisted LASIK were included. Only the left eye was included for analysis. Visual and refractive results were presented and compared between groups. The study comprised 105 patients (40 eyes in the small-incision lenticule extraction group and 65 eyes in the femtosecond laser-assisted LASIK group.) The mean preoperative manifest cylinder was -3.42 D ± 0.55 (SD) in the small-incision lenticule extraction group and -3.47 ± 0.49 D in the LASIK group (P = .655). At 3 months, there was no significant between-group difference in uncorrected distance visual acuity (P = .915) and manifest spherical equivalent (P = .145). Ninety percent and 95.4% of eyes were within ± 0.5 D of the attempted cylindrical correction for the small-incision lenticule extraction and LASIK group, respectively (P = .423). Vector analysis showed comparable target-induced astigmatism (P = .709), surgically induced astigmatism vector (P = .449), difference vector (P = .335), and magnitude of error (P = .413) between groups. The absolute angle of error was 1.88 ± 2.25 degrees in the small-incision lenticule extraction group and 1.37 ± 1.58 degrees in the LASIK group (P = .217). Small-incision lenticule extraction offered astigmatic correction comparable to LASIK in eyes with high myopic astigmatism. Copyright © 2018 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  14. 21 CFR 874.4500 - Ear, nose, and throat microsurgical carbon dioxide laser.

    Science.gov (United States)

    2010-04-01

    ... laser. 874.4500 Section 874.4500 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND..., nose, and throat microsurgical carbon dioxide laser. (a) Identification. An ear, nose, and throat microsurgical carbon dioxide laser is a device intended for the surgical excision of tissue from the ear, nose...

  15. A novel nomogram for the treatment of astigmatism with femtosecond-laser arcuate incisions at the time of cataract surgery

    Directory of Open Access Journals (Sweden)

    Baharozian CJ

    2017-10-01

    Full Text Available Connor J Baharozian,1 Christian Song,2,3 Kathryn M Hatch,2,3 Jonathan H Talamo2,3 1Boston University School of Medicine, 2Massachusetts Eye and Ear Infirmary, 3Department of Ophthalmology, Harvard Medical School, Boston, MA, USA Purpose: The purpose of this study was to determine an arcuate incision (AI nomogram to treat astigmatism during femtosecond laser-assisted cataract surgery. Methods: This is a retrospective, cohort study. Femtosecond laser (FSL-assisted transepithelial AIs were created at a 9.0 mm optical zone, 80% depth, centered on the limbus. We modified the manual Donnenfeld limbal relaxing incision nomogram to 70% for with-the-rule (WTR, 80% for oblique (OBL, and 100% for against-the-rule (ATR astigmatism. The correction index (CI equaled AI-induced astigmatism/target-induced astigmatism. Measures included preoperative keratometric corneal cylinder (Pre Kcyl, postoperative Kcyl (Post Kcyl, and postoperative residual refractive astigmatism (Post RRA. Results: Mean Pre Kcyl and 1–2 months Post RRA in 161 eyes of 116 patients were 0.626±0.417 diopters (D (range 0.5–2 D, and 0.495±0.400 D (range 0–1.5 D, respectively. Mean absolute astigmatic changes (Pre Kcyl–Post Kcyl without accounting for axis change in the WTR, ATR, and OBL groups were 0.165±0.383 D (P<0.001, 0.374±0.536 D (P<0.001, and 0.253±0.416 D (P=0.02, respectively. Mean absolute astigmatic changes using RRA as the postoperative measurement (Pre Kcyl–Post RRA without accounting for axis change were 0.440±0.461 D (P<0.001, 0.238±0.571 D (P<0.05, 0.154±0.450 (P=0.111 in WTR, ATR, and OBL groups, respectively. CIs for WTR, ATR, and OBL were 0.53, 1.01, and 0.95, respectively. There were no intraoperative or postoperative complications related to the AIs.Conclusion: Transepithelial FSL-AIs using the modified Donnenfeld nomogram show potential for management of mild to moderate corneal astigmatism. An increase in the magnitude or reduction of the optical zone

  16. The evaluation of tissue mass loss in the incision line of prostate with benign hyperplasia performed using holmium laser and cutting electrode.

    Science.gov (United States)

    Szewczyk, Mariusz; Jesionek-Kupnicka, Dorota; Lipiński, Marek Ireneusz; Lipinski, Piotr; Różański, Waldemar

    2014-01-01

    The aim of this study is to compare the changes in the incision line of prostatic adenoma using a monopolar cutting electrode and holmium laser, as well as the assessment of associated tissue mass and volume loss of benign prostatic hyperplasia (BPH). The material used in this study consisted of 74 preparations of prostatic adenoma obtained via open retropubic adenomectomy, with an average volume of 120.7 ml. The material obtained cut in vitro before fixation in formaldehyde. One lobe was cut using holmium laser, the other using a monopolar cutting electrode. After the incision was made, tissue mass and volume loss were evaluated. Thermocoagulation changes in the incision line were examinedunder light microscope. In the case of the holmium laser incision, the average tissue mass loss was 1.73 g, tissue volume loss 3.57 ml and the depth of thermocoagulation was 1.17 mm. When the monopolar cutting electrode was used average tissue mass loss was 0.807 g, tissue volume loss 2.48 ml and the depth of thermocoagulation was 0.19 mm. Where holmium laser was used, it was observed that the layer of tissue with thermocoagulation changes was deeper than in the case of the monopolar cutting electrode. Moreover, it was noticed that holmium laser caused bigger tissue mass and volume loss than the cutting electrode.

  17. A preliminary randomized clinical trial comparing diode laser and scalpel periosteal incision during implant surgery: impact on postoperative morbidity and implant survival.

    Science.gov (United States)

    Shahnaz, Aysan; Jamali, Raika; Mohammadi, Farnush; Khorsand, Afshin; Moslemi, Neda; Fekrazad, Reza

    2018-01-01

    The aim of this preliminary randomized clinical trial was to compare: (1) post-operative morbidity after application of laser or scalpel incision for flap advancement during implant surgery and bone grafting and (2) implant survival rate following flap advancement with laser or scalpel incision after 6 months of loading. Eighteen patients who were scheduled for dental implant placement and simultaneous bone grafting were randomly assigned to test or control groups. Diode laser (810 nm, 2 W, pulse interval 200 μs; pulse length 100 μs, 400-μm initiated fiber tip), or scalpel (control) was used to sever the periosteum to create a tension-free flap. Visual analogue scale (VAS) pain score, rate of nonsteroid anti-inflammatory drug (NSAID) consumption, intensity of swelling, and ecchymosis were measured for the six postsurgical days. Six months after loading, implant survival was assessed. VAS pain score (during the first four postoperative days), rate of NSAID consumption (during the first three postoperative days), and intensity of swelling (during the first five postoperative days) were significantly lower in the test group compared to the control group (All P values laser for performing periosteal releasing incision reduced the incidence and severity of postoperative morbidity of the patients undergone implant surgery in conjunction with bone augmentation procedure. We did not find any detrimental effect of laser incision on the implant survival within 6 months of loading.

  18. In vivo Molecular Evaluation of Guinea Pig Skin Incisions Healing after Surgical Suture and Laser Tissue Welding Using Raman Spectroscopy

    Science.gov (United States)

    Alimova, A.; Chakraverty, R.; Muthukattil, R.; Elder, S.; Katz, A.; Sriramoju, V.; Lipper, Stanley; Alfano, R. R.

    2009-01-01

    The healing process in guinea pig skin following surgical incisions was evaluated at the molecular level, in vivo, by the use of Raman spectroscopy. After the incisions were closed either by suturing or by laser tissue welding (LTW), differences in the respective Raman spectra were identified. The study determined that the ratio of the Raman peaks of the amide III (1247 cm−1) band to a peak at 1326 cm−1 (the superposition of elastin and keratin bands) can be used to evaluate the progression of wound healing. Conformational changes in the amide I band (1633 cm−1 to 1682 cm−1) and spectrum changes in the range of 1450 cm−1 to 1520 cm−1 were observed in LTW and sutured skin. The stages of the healing process of the guinea pig skin following LTW and suturing were evaluated by Raman spectroscopy, using histopathology as the gold standard. LTW skin demonstrated better healing than sutured skin, exhibiting minimal hyperkeratosis, minimal collagen deposition, near-normal surface contour, and minimal loss of dermal appendages. A wavelet decomposition-reconstruction baseline correction algorithm was employed to remove the fluorescence wing from the Raman spectra. PMID:19581109

  19. The use of the carbon dioxide laser in head and neck lymphangioma.

    Science.gov (United States)

    White, B; Adkins, W Y

    1986-01-01

    The carbon dioxide laser has been used to treat various lesions of the head and neck, ranging from carcinomas to hemangiomas, and even including tatoos. A search of the literature does not reveal any reports of the carbon dioxide laser being used to treat lymphangioma. This report discusses the efficacy of treating lymphangioma of the air and food passages with the carbon dioxide laser, and presents three patients who have been treated in this fashion-two for palliation and one for cure.

  20. Effects of electrocautery, CO/sub 2/ laser, and contact Nd:YAG laser scalpel on the healing of intestinal incision

    Energy Technology Data Exchange (ETDEWEB)

    Puolakkainen, P.; Brackett, K.; Sankar, M.Y.; Joffe, S.; Schroeder, T.

    1987-01-01

    Leakage after intestinal resection is a serious complication with a high mortality rate. A recent study claims that cutting the intestine with the CO/sub 2/ laser improves the healing of intestinal anastomoses. The present study was undertaken to analyze the effects of electrocautery, CO/sub 2/ laser, and contact Nd:YAG laser on the healing of intestinal incisions. Fifteen piglets were used and the cutting and reanastomosing were performed by using all cutting methods in each animal in randomized order. Resection sites were 50 cm, 100 cm, and 150 cm distal to the ligament of Treitz. On the seventh day the bursting pressures were measured for each anastomosis. They were 172 +/- 17 mmHg for normal bowel segment and 133 +/- 12, 135 +/- 40, and 139 +/- 17 mmHg for electrocautery, CO/sub 2/ laser, and Nd:YAG laser, respectively. There were no mortality, no anastomotic leaks, and no statistically significant differences in the bursting pressures, in histology, or in the healing of anastomotic sites, indicating that electrocautery, CO/sub 2/ laser, and contact Nd:YAG laser scalpel can safely be used in the surgery of small intestine.

  1. Calculation of the characteristics of carbon dioxide TEA photoionization lasers

    Energy Technology Data Exchange (ETDEWEB)

    Aver' yanov, N E; Baloshin, Yu A; Gerke, M N; Dernyatin, A I; Khurgin, Ya B

    1979-01-01

    A mathematical model is proposed for studying the characteristics of a carbon dioxide photoionization laser with pressures of the active mixture of the order of one atmosphere. The kinetics of the CO/sub 2/ molecules is described in terms of population of the group of lower vibrational levels. The part played by N/sub 2/ molecules in the general system of kinetic equations is accounted for by a harmonic oscillator model with Boltzmann population of vibrational levels and the corresponding vibrational temperature. A diagram is given of the fundamental kinetic processes in the proposed model for a TEA laser. The results of calculations are compared with a previously proposed model and with experimental data for a carbon dioxide TEA photoionization laser using preionization by ultraviolet radiation and operating in the semi-selfmaintained discharge mode. The active mixture was CO/sub 2/:N/sub 2/:He=1:1:8. It was found that optimum mixtures for maximum power are those with ratios of CO/sub 2/:N/sub 2/He=5:45:50, 10:40:50 and 5:55:40. The helium molecules supply most of the photoelectrons, and the additives give a uv spectrum that is optimum for photoionization of He. The CO/sub 2/ is the lasing molecule, but absorbs uv radiation, and therefore the optimum CO/sub 2/ concentration is low. The influence that dissociation of CO/sub 2/ molecules has on the laser depends on the electron concentration in the main discharge. Any model that reliably describes laser characteristics must take account of dissociation of the lasing molecules by means of some factor that shows how many molecules are dissociated by uv radiation, although the dissociation by electron impact can be disregarded.

  2. Optical performance of the Gemini carbon dioxide laser fusion system

    International Nuclear Information System (INIS)

    Viswanathan, V.K.; Hayden, J.J.; Liberman, I.

    1979-01-01

    The performance of the Gemini two beam carbon dioxide laser fusion system was recently upgraded by installation of optical components with improved quality in the final amplifier. A theoretical analysis was conducted in conjunction with measurements of the new performance. The analysis and experimental procedures, and results obtained are reported and compared. Good agreement was found which was within the uncertainties of the analysis and the inaccuracies of the experiments. The focal spot Strehl ratio was between 0.24 and 0.3 for both beams

  3. Nondébridement of laser char after two carbon dioxide laser passes results in faster reepithelialization

    DEFF Research Database (Denmark)

    Collawn, Sherry S; Woods, Anne; Couchman, John R

    2003-01-01

    Skin repair following laser injury can be accelerated by using techniques that promote rapid reepithelialization. In this article, the benefit of intraoperative nondébridement of laser debris after two laser passes is discussed. After carbon dioxide laser resurfacing of the face, skin specimens w...

  4. Wound repair in rat urinary bladder following electrocautery or holmium laser incision

    Science.gov (United States)

    Venzi, Giordano; Schmidlin, Franz R.; Gabbiani, Giulio; Delacretaz, Guy P.; Pittet, Brigitte; Leisinger, Hans-Juerg; Iselin, Christoph E.

    1999-06-01

    Woundhealing is a complex phenomenon which varies according the type of tissue but is also depending from the type of tissue injury. Electrocautery mainly induces coagulation necrosis while thermal damages induced by the Holmium laser primarily lead to tissue vaporization which may induce less tissue injury. The aim of this study was to evaluate the healing process of the Holmium laser induced lesions compared to electrocautery induced lesions in urothelial tissue by assessing the inflammatory response and myofibroblast behavior in sequential healing phases. A surgical wound was created in the urinary rat bladder of 32 rats either by electrocautery or by laser (N=16). The inflammatory response, the total lesion depth and the myofibroblast activity during woundhealing was then analyzed on a qualitative basis on days 0/2/4/8. The overall inflammatory response was comparable in both groups up to days two and four. However, at day eight less cellular inflammatory reaction and less myofibroblast activity was found in the specimen of lesions created by the Holmium laser. These results suggest that wound repair may be a less invasive process after Holmium laser than electrocautery.

  5. A novel nomogram for the treatment of astigmatism with femtosecond-laser arcuate incisions at the time of cataract surgery.

    Science.gov (United States)

    Baharozian, Connor J; Song, Christian; Hatch, Kathryn M; Talamo, Jonathan H

    2017-01-01

    The purpose of this study was to determine an arcuate incision (AI) nomogram to treat astigmatism during femtosecond laser-assisted cataract surgery. This is a retrospective, cohort study. Femtosecond laser (FSL)-assisted transepithelial AIs were created at a 9.0 mm optical zone, 80% depth, centered on the limbus. We modified the manual Donnenfeld limbal relaxing incision nomogram to 70% for with-the-rule (WTR), 80% for oblique (OBL), and 100% for against-the-rule (ATR) astigmatism. The correction index (CI) equaled AI-induced astigmatism/target-induced astigmatism. Measures included preoperative keratometric corneal cylinder (Pre Kcyl), postoperative Kcyl (Post Kcyl), and postoperative residual refractive astigmatism (Post RRA). Mean Pre Kcyl and 1-2 months Post RRA in 161 eyes of 116 patients were 0.626±0.417 diopters (D) (range 0.5-2 D), and 0.495±0.400 D (range 0-1.5 D), respectively. Mean absolute astigmatic changes (Pre Kcyl-Post Kcyl) without accounting for axis change in the WTR, ATR, and OBL groups were 0.165±0.383 D ( P <0.001), 0.374±0.536 D ( P <0.001), and 0.253±0.416 D ( P =0.02), respectively. Mean absolute astigmatic changes using RRA as the postoperative measurement (Pre Kcyl-Post RRA) without accounting for axis change were 0.440±0.461 D ( P <0.001), 0.238±0.571 D ( P <0.05), 0.154±0.450 ( P =0.111) in WTR, ATR, and OBL groups, respectively. CIs for WTR, ATR, and OBL were 0.53, 1.01, and 0.95, respectively. There were no intraoperative or postoperative complications related to the AIs. Transepithelial FSL-AIs using the modified Donnenfeld nomogram show potential for management of mild to moderate corneal astigmatism. An increase in the magnitude or reduction of the optical zone size for the treatment of WTR and ATR astigmatism for this nomogram may further improve refractive accuracy.

  6. Ultrapulse carbon dioxide laser ablation of xanthelasma palpebrarum: A case series

    Directory of Open Access Journals (Sweden)

    Vikas Pathania

    2015-01-01

    Full Text Available Context: Xanthelasma palpebrarum is the most common form of xanthomas. Albeit a benign entity, it is cosmetically disturbing and a frequently recurring dermatologic referral. Although the classical treatment option remains surgical excision, alternatively, chemical cauterization, cryosurgery and electrofulguration have all been tried in the past with mixed results. The use of laser systems such as carbon dioxide laser, Erb:YAG laser, Q-switched Nd:YAG laser, diode laser, pulsed dye laser and KTP laser have become popular in the treatment of these lesions. Recent literature suggests minimal pigmentary changes and scarring with the use of ultrapulse carbon dioxide laser treatment of these lesions. Aim: To study and evaluate the effectiveness of ultrapulse carbon dioxide laser ablation for treatment of xanthelasma palpebrarum. Materials and Methods: 10 patients presenting with bilateral xanthelasma palpebrarum, new and with recurrence were studied for results after a single treatment with ultrapulse carbon dioxide laser (10,600 nm; 100-200 Hz; 200-400 μsec. The follow-up time was 9 months. Results: All lesions were treatable with a single-laser treatment session. Two patients (20% developed recurrence during the follow-up period. Side effects included post inflammatory hyperpigmentation in two patients (20%, but no visible scarring was observed. Conclusions: The ultrapulse carbon dioxide laser is an effective and safe therapeutic alternative in treatment of xanthelasma palpebrarum.

  7. Recurrence of vocal fold leukoplakia after carbon dioxide laser therapy.

    Science.gov (United States)

    Chen, Min; Chen, Jian; Cheng, Lei; Wu, Haitao

    2017-09-01

    This work aims to analyze the recurrence of vocal fold leukoplakia after carbon dioxide (CO 2 ) laser resection. In this retrospective study, all patients undergoing CO 2 laser resection of vocal fold leukoplakia were followed up for at least 2 years. Recurrence was diagnosed as any presence of leukoplakia in the vocal cord subsequent to previous successful complete resection. A total of 326 patients with complete resection of vocal fold leukoplakia and follow-up subsequent surveillance laryngoscopy were studied. The recurrence rate, the recurrence time, and risk factors were evaluated. Of these, 52 (16.0%) patients experienced recurrence with a mean follow-up time of 50.5 ± 15.4 months. The mean time to recurrence was 16.2 ± 14.1 months. Univariate analysis showed that the size of lesion (P vocal fold leukoplakia, long-term follow-up is required after CO 2 laser resection. In conclusion, the size of lesion combined with the pathological grade are important risk factors that predict vocal fold leukoplakia recurrence.

  8. Confocal comparison of corneal reinnervation after small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK).

    Science.gov (United States)

    Li, Meiyan; Niu, Lingling; Qin, Bing; Zhou, Zimei; Ni, Katherine; Le, Qihua; Xiang, Jun; Wei, Anji; Ma, Weiping; Zhou, Xingtao

    2013-01-01

    To evaluate corneal reinnervation, and the corresponding corneal sensitivity and keratocyte density after small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK). In this prospective, non-randomized observational study, 18 patients (32 eyes) received SMILE surgery, and 22 patients (42 eyes) received FS-LASIK surgery to correct myopia. The corneal subbasal nerve density and microscopic morphological changes in corneal architecture were evaluated by confocal microscopy prior to surgery and at 1 week, 1 month, 3 months, and 6 months after surgery. A correlation analysis was performed between subbasal corneal nerve density and the corresponding keratocyte density and corneal sensitivity. The decrease in subbasal nerve density was less severe in SMILE-treated eyes than in FS-LASIK-treated eyes at 1 week (P = 0.0147), 1 month (P = 0.0243), and 3 months (P = 0.0498), but no difference was detected at the 6-month visit (P = 0.5277). The subbasal nerve density correlated positively with central corneal sensitivity in both groups (r = 0.416, PLASIK group, respectively). The SMILE-treated eyes have a lower risk of developing peripheral empty space with epithelial cells filling in (P = 0.0005). The decrease in subbasal nerve fiber density was less severe in the SMILE group than the FS-LASIK group in the first 3 months following the surgeries. The subbasal nerve density was correlated with central corneal sensitivity.

  9. Early corneal nerve damage and recovery following small incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK).

    Science.gov (United States)

    Mohamed-Noriega, Karim; Riau, Andri K; Lwin, Nyein C; Chaurasia, Shyam S; Tan, Donald T; Mehta, Jodhbir S

    2014-03-25

    We compared early corneal nerve changes after small incision lenticule extraction (SMILE) and laser in situ keratomileusis (LASIK). A total of 12 rabbits underwent LASIK in one eye and SMILE in the fellow eye. Baseline and follow-up evaluations at 1, 2, and 4 weeks postoperatively were performed with in vivo confocal microscopy to evaluate 5 different areas within the treated zone: center, superior, inferior, nasal, and temporal. Cryosections of the corneas and whole mount of the extracted SMILE lenticules were analyzed with immunostaining of βIII-tubulin. One week after SMILE and LASIK, a decrease in nerve length and density was observed in all evaluated areas. A trend toward greater subbasal nerve length and density (SLD), more eyes with subbasal nerves (ESN), more eyes with subbasal nerves longer than 200 μm (SNL), and higher mean number of subbasal nerves by frame (NSN) in SMILE than in LASIK groups was observed at subsequent follow-up time points. Only the SMILE group showed a recovery of SLD, ESN, and NSN by week 4 (P > 0.05). A trend toward more eyes with sprouting subbasal nerves and greater mean number of sprouting nerves was observed in LASIK than in SMILE, indicating that more subbasal nerves were disrupted and undergoing regeneration after LASIK. Immunostaining at postoperative week 4 revealed a faster stromal nerve recovery in post-SMILE eyes compared to post-LASIK eyes. Our findings suggest that SMILE results in less nerve damage and faster nerve recovery than LASIK.

  10. Comparison of corneal sensation between small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK for myopia.

    Science.gov (United States)

    Li, Meiyan; Zhou, Zimei; Shen, Yang; Knorz, Michael C; Gong, Lan; Zhou, Xingtao

    2014-02-01

    To compare the impact on corneal sensation after small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK (femto-LASIK) in patients with myopia. In this prospective, nonrandomized comparative study, 71 subjects were enrolled. Thirty-eight eyes of 38 patients underwent SMILE and 33 eyes of 33 patients underwent femto-LASIK. Corneal sensation was tested with Cochet-Bonnet esthesiometry in five corneal areas preoperatively and at 1 week and 1, 3, and 6 months postoperatively. Comparison of corneal sensation was performed for the SMILE and femto-LASIK groups. Additionally, the correlations were evaluated between the postoperative corneal sensation, preoperative spherical equivalent, and ablation depth. All tested areas within the cap or flap demonstrated corneal hypoesthesia immediately after both surgeries. SMILE-treated eyes showed less compromised corneal sensation than femto-LASIK-treated eyes at all postoperative visits in the central, inferior, nasal, and temporal areas at the 1-week and 1-month visits. In the SMILE group, the inferior, nasal, and temporal quadrants recovered faster than other areas. In the femto-LASIK group, the sensation over the flap did not recover to preoperative levels by postoperative 6 months. There was no correlation between postoperative corneal sensation, preoperative spherical equivalent, and ablation depth in both groups. The impairment of corneal sensation was less significant in the SMILE group than in the femto-LASIK group and was independent of preoperative spherical equivalent or ablation depth. Copyright 2014, SLACK Incorporated.

  11. Pulsed liquid jet dissector using holmium: YAG laser - a novel neurosurgical device for brain incision without imparing vessels

    International Nuclear Information System (INIS)

    Hirano, T.; Nakagawa, A.; Jokura, H.; Shirane, R.; Uenohara, H.; Ohyama, H.; Takayama, K.

    2003-01-01

    Neurosurgery has long required a method for dissecting brain tissue without damaging principal vessels and adjacent tissue, so as to prevent neurological complications after operation. In this study we constructed a prototype of such a device and used it in an attempt to resect beagle brain cortex. The prototype device consisted of an optical fiber, a Y adapter, and a nozzle whose internal exit diameter was 100 μm. Cold physiological saline (4 o C) was supplied to it at a rate of 40 ml/h. Pulsed liquid jets were ejected from the nozzle by a pulsed Holmium:YAG) (Ho:YAG) laser at an irradiation energy of 300 mJ/pulse. The profile of the liquid jet was observed with a high-speed camera while changing the distance between the optical fiber end and nozzle exit (equivalent to the Standoff distance). With this device (3 Hz operation), brain dissection of anesthetized beagles was attempted while measuring the local temperature of the target. A histological study of the incised parts was also performed. When the Standoff distance was 24 mm, the liquid jet was emitted straight from the nozzle at a maximum initial velocity of 50 m/s. The brain parenchyma was cut with this device while preserving vessels larger than 200 μm in diameter and keeping the operative field clear. The local temperature rose to no more than 41 o C, below the functional heat damage threshold of brain tissue. Histological findings showed no signs of thermal tissue damage around the dissected margin. The Ho:YAG laser-induced liquid jet dissector can be applied to neurosurgery after incorporating some minor improvements. (author)

  12. Comparison of the corneal biomechanical effects after small-incision lenticule extraction and Q value guided femtosecond laser-assisted laser in situ keratomileusis

    Directory of Open Access Journals (Sweden)

    Jun Zhang

    2016-04-01

    Full Text Available AIM:By comparing the changes of biomechanical properties of the cornea after small-incision lenticule extraction(SMILEand those after Q value guided femtosecond laser-assisted laser in situ keratomileusis(FSLASIK, to study the stability of biomechanical properties of the cornea after these two kinds of surgery and provide objective data for clinical operation.METHODS: Prospective comparative cases. One hundred and two cases(200 eyeswith myopia and myopic astigmatism were divided into 2 groups, 51 cases(100 eyesfor SMILE, and 51 cases(100 eyesfor Q value guided FS-LASIK. Corneal hysteresis(CHand the corneal resistance factor(CRFwere quantitatively assessed with the Ocular Response Analyzer(ORApreoperatively and 1d, 2wk, 1 and 3mo postoperatively.RESULTS: The decrease in CH and the CRF were statistically significant in both groups(PP>0.05. There were no statistically significant differences between the biomechanical changes in the two groups at any time(P>0.05.CONCLUSION: Both SMILE and Q value guided FS-LASIK can cause biomechanical decreases in the cornea. After 1d postoperatively, the decreases are nearly stable. There are no significant differences between the effect of SMILE and Q value guided FS-LASIK on the biomechanical properties of the cornea.

  13. Clinical outcomes of small incision lenticule extraction versus femtosecond laser-assisted LASIK for myopia: a Meta-analysis

    Science.gov (United States)

    Yan, Huan; Gong, Li-Yan; Huang, Wei; Peng, Yan-Li

    2017-01-01

    AIM To evaluate the possible differences in visual quality between small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) for myopia. METHODS A Meta-analysis was performed. Patients were from previously reported comparative studies treated with SMILE versus FS-LASIK. The PubMed, EMBASE, Cochrane, Web of Science and Chinese databases (i.e. WANFANG and CNKI) were searched in Nov. of 2016 using RevMan 5.1 version software. The differences in visual acuity, aberration and biomechanical effects within six months postoperatively were showed. Twenty-seven studies including 4223 eyes were included. RESULTS No significant differences were observed between SMILE and FS-LASIK in terms of the proportion of eyes that lost one or more lines of corrected distance visual acuity after surgery (P=0.14), the proportion of eyes achieving an uncorrected distance visual acuity of 20/20 or better (P=0.43), the final refractive spherical equivalent (P=0.89), the refractive spherical equivalent within ±1.00 diopter of the target values (P=0.80), vertical coma (P=0.45) and horizontal coma (P=0.06). Compared with the FS-LASIK group, total higher-order aberration (PLASIK are comparable in efficacy, safety and predictability for correcting myopia. However, the aberration in the SMILE group is superior to that in the FS-LASIK group, and the loss of biomechanical effects may occur less frequently after SMILE than after FS-LASIK. PMID:28944205

  14. Confocal comparison of corneal reinnervation after small incision lenticule extraction (SMILE and femtosecond laser in situ keratomileusis (FS-LASIK.

    Directory of Open Access Journals (Sweden)

    Meiyan Li

    Full Text Available PURPOSE: To evaluate corneal reinnervation, and the corresponding corneal sensitivity and keratocyte density after small incision lenticule extraction (SMILE and femtosecond laser in situ keratomileusis (FS-LASIK. METHODS: In this prospective, non-randomized observational study, 18 patients (32 eyes received SMILE surgery, and 22 patients (42 eyes received FS-LASIK surgery to correct myopia. The corneal subbasal nerve density and microscopic morphological changes in corneal architecture were evaluated by confocal microscopy prior to surgery and at 1 week, 1 month, 3 months, and 6 months after surgery. A correlation analysis was performed between subbasal corneal nerve density and the corresponding keratocyte density and corneal sensitivity. RESULTS: The decrease in subbasal nerve density was less severe in SMILE-treated eyes than in FS-LASIK-treated eyes at 1 week (P = 0.0147, 1 month (P = 0.0243, and 3 months (P = 0.0498, but no difference was detected at the 6-month visit (P = 0.5277. The subbasal nerve density correlated positively with central corneal sensitivity in both groups (r = 0.416, P<0.0001, and r = 0.2567, P = 0.0038 for SMILE group and FS-LASIK group, respectively. The SMILE-treated eyes have a lower risk of developing peripheral empty space with epithelial cells filling in (P = 0.0005. CONCLUSIONS: The decrease in subbasal nerve fiber density was less severe in the SMILE group than the FS-LASIK group in the first 3 months following the surgeries. The subbasal nerve density was correlated with central corneal sensitivity.

  15. Optical wave microphone measurements of laser ablation of copper in supercritical carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Mitsugi, Fumiaki, E-mail: mitsugi@cs.kumamoto-u.ac.jp [Graduate School of Science and Technology, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Ikegami, Tomoaki [Graduate School of Science and Technology, Kumamoto University, 2-39-1 Kurokami, Kumamoto 860-8555 (Japan); Nakamiya, Toshiyuki; Sonoda, Yoshito [Graduate School of Industrial Engineering, Tokai University, 9-1-1 Toroku, Kumamoto 862-8652 (Japan)

    2013-11-29

    Laser ablation plasma in a supercritical fluid has attracted much attention recently due to its usefulness in forming nanoparticles. Observation of the dynamic behavior of the supercritical fluid after laser irradiation of a solid is necessary for real-time monitoring and control of laser ablation. In this study, we utilized an optical wave microphone to monitor pulsed laser irradiation of a solid in a supercritical fluid. The optical wave microphone works based on Fraunhofer diffraction of phase modulation of light by changes in refractive index. We hereby report on our measurements for pulsed laser irradiation of a Cu target in supercritical carbon dioxide using an optical wave microphone. Photothermal acoustic waves which generated after single pulsed laser irradiation of a Cu target were detectable in supercritical carbon dioxide. The speed of sound around the critical point of supercritical carbon dioxide was clearly slower than that in gas. The optical wave microphone detected a signal during laser ablation of Cu in supercritical carbon dioxide that was caused by shockwave degeneration. - Highlights: • Photothermal acoustic wave in supercritical fluid was observed. • Sound speed around the critical point was slower than that in gas. • Optical wave microphone detected degeneration of a shockwave. • Ablation threshold of a solid in supercritical fluid can be estimated. • Generation of the second shockwave in supercritical phase was suggested.

  16. The Successful Treatment of Elephantiasis Nostras Verrucosa With Ablative Carbon Dioxide Laser.

    Science.gov (United States)

    Robinson, Caitlin G; Lee, Kory R; Thomas, Valencia D

    2018-03-01

    Elephantiasis nostras verrucosa (ENV) is a disfiguring skin condition that is difficult to treat. Existing treatment modalities serve to improve cosmesis or treat symptoms. Herein, we report a case of ENV with lymphocutaneous fistula successfully treated with ablative carbon dioxide laser. A 57-year-old woman with biopsy-proven ENV with lymphocutaneous fistula was treated with ablative carbon dioxide laser to the symptomatic area of her right thigh in 3 treatment sessions over 6 months. The patient had resolution of lymphocutaneous drainage as well as 90% improvement in the appearance of ENV lesions at the 1-month follow-up visit. Ablative carbon dioxide laser may provide cosmetic, symptomatic, and medical benefit for patients with localized ENV.

  17. Discovery of natural gain amplification in the 10-micrometer carbon dioxide laser bands on Mars - A natural laser

    Science.gov (United States)

    Mumma, M. J.; Buhl, D.; Chin, G.; Deming, D.; Espenak, F.; Kostiuk, T.; Zipoy, D.

    1981-01-01

    Fully resolved intensity profiles of various lines in the carbon dioxide band at 10.4 micrometers have been measured on Mars with an infrared heterodyne spectrometer. Analysis of the line shapes shows that the Mars atmosphere exhibits positive gain in these lines. The detection of natural optical gain amplification enables identification of these lines as a definite natural laser.

  18. Carbon dioxide laser versus erbium:YAG laser in treatment of epidermal verrucous nevus: a comparative randomized clinical study.

    Science.gov (United States)

    Osman, Mai Abdel Raouf; Kassab, Ahmed Nazmi

    2017-08-01

    A verrucous epidermal nevus (VEN) is a skin disorder that has been treated using different treatment modalities with varying results. Ablative lasers such as carbon dioxide laser (CO 2 ) and erbium:yttrium-aluminum-garnet (Er:YAG) laser have been considered as the gold standard for the treatment of epidermal nevi. To evaluate and compare the efficacy, postoperative wound healing and side effects of pulsed CO 2 laser and Er:YAG laser for the treatment of verrucous epidermal nevi. Twenty patients with localized VEN were randomly divided into two groups. Group 1 was administered CO 2 laser and group 2 underwent Er:YAG laser treatment. A blinded physician evaluated the photographs and dermoscopic photomicrographs for the efficacy and possible side effects. All patients received one treatment session and were followed up over a 6-month period. Both lasers induced noticeable clinical improvement, but there were no significant differences between two lasers in treatment response, patient satisfaction, duration of erythema and side effects. The average time to re-epithelialization was 13.5 days with CO 2 and 7.9 days with Er:YAG laser (plaser group and no lesional recurrence was detected in CO 2 laser group since treatment. Apart from re-epithelialization, both lasers showed equivalent outcomes with respect to treatment response, patient satisfaction, side effects and complications.

  19. Cervical osteomyelitis after carbon dioxide laser excision of recurrent carcinoma of the posterior pharyngeal wall

    NARCIS (Netherlands)

    Timmermans, A. Jacqueline; Brandsma, Dieta; Smeele, Ludi E.; Rosingh, Andert W.; van den Brekel, Michiel W. M.; Lohuis, Peter J. F. M.

    2013-01-01

    Two patients with recurrent carcinoma of the posterior pharyngeal wall, previously treated with carbon dioxide (CO2) laser excision and (chemo)radiotherapy, presented with neck pain due to cervical osteomyelitis. In one patient this led to cervical spine instability, for which a haloframe was

  20. Carbon dioxide laser absorption spectra of toxic industrial compounds

    International Nuclear Information System (INIS)

    Loper, G.L.; Sasaki, G.R.; Stamps, M.A.

    1982-01-01

    CO 2 laser absorption cross-section data are reported for acrolein, styrene, ethyl acrylate, trichloroethylene, vinyl bromide, and vinylidene chloride. These data indicate that sub parts per billion level, interference-free detection limits should be possible for these compounds by the CO 2 laser photoacoustic technique. Photoacoustic detectabilities below 40 ppb should be possible for these compounds in the presence of ambient air concentrations of water vapor and other anticipated interferences. These compounds are also found not to be important inerference in the detection of toxic hydrazine-based rocket fuels by CO 2 laser spectroscopic techniques

  1. Control-matched comparison of refractive and visual outcomes between small incision lenticule extraction and femtosecond laser-assisted LASIK

    Directory of Open Access Journals (Sweden)

    Kataoka T

    2018-05-01

    Full Text Available Takahiro Kataoka,1 Tomoya Nishida,1 Azusa Murata,1 Mayuka Ito,1 Naoki Isogai,1 Rie Horai,1 Takashi Kojima,1,2 Yoko Yoshida,1 Tomoaki Nakamura1 1Nagoya Eye Clinic, Nagoya, Japan; 2Department of Ophthalmology, Keio University School of Medicine, Tokyo, Japan Purpose: This retrospective case-matched study aimed to compare visual and refractive outcomes between small incision lenticule extraction (SMILE and LASIK. Patients and methods: Patients who underwent SMILE (34 eyes of 23 patients or LASIK (34 eyes of 24 patients were enrolled and matched according to preoperative manifest refractive spherical equivalents. The mean preoperative manifest refractive spherical equivalent was −4.69±0.6 and −4.67±0.64 D in the SMILE and LASIK groups, respectively. The safety, efficacy, and predictability were compared 3 months after surgery. Changes in corneal refractive power from the center to peripheral points and their maintenance ratios were analyzed and compared between the two groups. Results: In the SMILE and LASIK groups, 82.4% and 85.3% of patients, respectively, achieved 20/13 or better uncorrected distance visual acuity (p=1.00. There were no eyes that lost two or more lines of corrected distance visual acuity in either group. The maintenance ratios of corneal refractive power changes at the peripheral points in the SMILE group were significantly higher than those in the LASIK group (p<0.05. Conclusion: Both groups achieved similar high efficacy and safety. SMILE surgery resulted in higher refractive power correction in the peripheral cornea than LASIK surgery. Keywords: small incision lenticule extraction, LASIK, corneal refractive power, refractive power correction efficiency, corneal topography

  2. Diffuse Urticarial Reaction Associated with Titanium Dioxide Following Laser Tattoo Removal Treatments.

    Science.gov (United States)

    Willardson, Hal Bret; Kobayashi, Todd T; Arnold, Jason G; Hivnor, Chad M; Bowen, Casey D

    2017-03-01

    Local and generalized allergic reactions following laser tattoo removal have been documented, but are rare. To our knowledge, this is the fourth documented case of widespread urticarial eruptions following laser tattoo removal treatment. Unlike previously documented cases, this patient's reaction was found to be associated with titanium dioxide within the tattoo and her symptoms were recalcitrant to medical therapy. A 46-year-old female experienced diffuse urticarial plaques, erythema, and pruritis following multiple laser tattoo removal treatments with an Nd:YAG laser. The systemic allergic reaction was recalcitrant to increasing doses of antihistamines and corticosteroids. The tattoo was finally surgically excised. The excised tissue was analyzed by scanning electron microscopy and energy-dispersive X-ray analysis and contained high levels of titanium dioxide. Two weeks following the excision, and without the use of medical therapy, the patient had complete resolution of her generalized urticaria. Ours is the first documented case of a diffuse urticarial reaction following laser tattoo removal treatments that shows a strong association to titanium dioxide within the tattoo pigment. Herein, we describe a novel surgical approach to treat recalcitrant generalized allergic reaction to tattoo pigment.

  3. The role of transforming growth factor β1 in fractional laser resurfacing with a carbon dioxide laser.

    Science.gov (United States)

    Jiang, Xia; Ge, Hongmei; Zhou, Chuanqing; Chai, Xinyu; Deng, Hui

    2014-03-01

    The aim of this study was to investigate the role of transforming growth factor β1 in mechanisms of cutaneous remodeling induced by fractional carbon dioxide laser treatment. The dorsal skin of Kunming mice was exposed to a single-pass fractional CO2 laser treatment. Biopsies were taken at 1 h and at 1, 3, 7, 14, 21, 28, and 56 days after treatment. Transforming growth factor (TGF) β1 expression in skin samples was evaluated by ELISA, dermal thickness by hematoxylin-eosin staining, collagen and elastic fibers by Ponceau S and Victoria blue double staining, and types I and III collagens by ELISA. The level of TGF β1 in the laser-treated areas of skin was significantly increased compared with that in the control areas on days 1 (p skin of the laser-treated areas had increased significantly (p resurfacing.

  4. Optically pumped carbon dioxide laser mixtures. [using solar radiation

    Science.gov (United States)

    Yesil, O.; Christiansen, W. H.

    1979-01-01

    This work explores the concept of blackbody radiation pumping of CO2 gas as a step toward utilization of solar radiation as a pumping source for laser action. To demonstrate this concept, an experiment was performed in which laser gas mixtures were exposed to 1500 K thermal radiation for brief periods of time. A gain of 2.8 x 10 to the -3rd reciprocal centimeters has been measured at 10.6 microns in a CO2-He gas mixture of 1 Torr pressure. A simple analytical model is used to describe the rate of change of energy of the vibrational modes of CO2 and to predict the gain. Agreement between the prediction and experiment is good.

  5. Pulsed TEA CO2 Laser Irradiation of Titanium in Nitrogen and Carbon Dioxide Gases

    Science.gov (United States)

    Ciganovic, J.; Matavulj, P.; Trtica, M.; Stasic, J.; Savovic, J.; Zivkovic, S.; Momcilovic, M.

    2017-12-01

    Surface changes created by interaction of transversely excited atmospheric carbon dioxide (TEA CO2) laser with titanium target/implant in nitrogen and carbon dioxide gas were studied. TEA CO2 laser operated at 10.6 μm, pulse length of 100 ns and fluence of ˜17 J/cm2 which was sufficient for inducing surface modifications. Induced changes depend on the gas used. In both gases the grain structure was produced (central irradiated zone) but its forms were diverse, (N2: irregular shape; CO2: hill-like forms). Hydrodynamic features at peripheral zone, like resolidified droplets, were recorded only in CO2 gas. Elemental analysis of the titanium target surface indicated that under a nitrogen atmosphere surface nitridation occurred. In addition, irradiation in both gases was followed by appearance of plasma in front of the target. The existence of plasma indicates relatively high temperatures created above the target surface offering a sterilizing effect.

  6. Phase aberrations and beam cleanup techniques in carbon-dioxide laser fusion systems

    International Nuclear Information System (INIS)

    Viswanathan, V.K.

    1981-01-01

    This paper describes the various carbon dioxide laser fusion systems at Los Alamos from the point of view of an optical designer. The types of phase aberrations present in these systems, as well as the beam cleanup techniques that can be used to improve the beam optical quality, are discussed. As this is a review article, some previously published results are also used where relevant

  7. Experimental investigations of driven Alfven wave resonances in a tokamak plasma using carbon dioxide laser interferometry

    International Nuclear Information System (INIS)

    Evans, T.E.

    1984-09-01

    The first direct observation of the internal structure of driven global Alfven eigenmodes in a tokamak plasma is presented. A carbon dioxide laser scattering/interferometer has been designed, built, and installed on the PRETEXT tokamak. By using this diagnostic system in the interferometer configuration, we have for the first time, thoroughly investigated the resonance conditions required for, and the spatial wave field structure of, driven plasma eigenmodes at frequencies below the ion cyclotron frequency in a confined, high temperature, tokamak plasma

  8. Small Incision Lenticule Extraction (SMILE) vs. Femtosecond Laser in Situ Keratomileusis (FS-LASIK) for treatment of myopia

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Justesen, Birgitte

    Purpose: - 67 ord LASIK has been the dominating corneal refractive procedure for almost two decades, but the new flap-free SMILE procedure has shown promising results. The aim of this study was to evaluate and compare refractive predictability, uncorrected and corrected distance visual acuity (UDVA...... and CDVA), and safety at 1 day, 1 week and 3 months after SMILE and FS-LASIK for all degrees of myopia, but in particular high myopia. Setting: Department of Ophthalmology, Odense University Hospital, Odense, Denmark Methods: - 157 ord Retrospective study of results after SMILE and FS-LASIK for all degrees...... having undergone re-treatment. The SMILE treatments and FS-LASIK flaps were performed with a VisuMax® femtosecond laser (Carl Zeiss-Meditec, Jena, Germany). The FS-LASIK photoablation was performed with a MEL-80 flying-spot excimer laser with eye-tracker (Carl Zeiss-Meditec, Jena, Germany). In SMILE...

  9. The advantages of carbon dioxide laser applications in paediatric oral surgery. A prospective cohort study.

    Science.gov (United States)

    Hanna, R; Parker, S

    2016-11-01

    The aim of this study is to evaluate and demonstrate the advantages of the carbon dioxide laser in paediatric oral surgery patients in terms of less post-operative complications, healing without scaring, functional benefits, positive patient perception and acceptance of the treatment. One hundred fit and healthy paediatric patients (aged 4-15 years) were recruited to undergo laser surgery for different soft tissue conditions. The outcome of these laser treatments was examined. The Wong-Baker Faces Pain Rating Scale was employed to evaluate the pain before, immediately after laser treatment in the clinic and 1 day after post-operatively at home. Post-operative complications and patients' perception and satisfaction were self-reported during a review telephone call the day after treatment. The patients were reviewed 2 weeks after surgery. Laser parameter was 1.62 W, measured by power meter, continuous wave mode with 50 % emission cycle. The beam spot size at the target tissue was 0.8 mm. The pain score pre-operative, during and immediately after laser treatment was rated 0. Whilst the pain score 1 day after surgery was rated between 0 and 2, the healing time was measured over 2 weeks. None of the patients reported post-operative complications after surgery. Patients' perception and acceptance were rated very good. Laser dentistry is a promising field in modern minimally invasive dentistry, which enables provision of better care for children and adolescents. In this cohort study, the use of the carbon dioxide laser therapy offers a desirable, acceptable and minimally invasive technique in the surgical management of soft tissues in paediatric oral surgery with minimal post-operative complications.

  10. Water vapor absorption of carbon dioxide laser radiation

    Science.gov (United States)

    Shumate, M. S.; Menzies, R. T.; Margolis, J. S.; Rosengren, L.-G.

    1976-01-01

    An optoacoustic detector or spectrophone has been used to perform detailed measurements of the absorptivity of mixtures of water vapor in air. A (C-12) (O-16)2 laser was used as the source, and measurements were made at forty-nine different wavelengths from 9.2 to 10.7 microns. The details of the optoacoustic detector and its calibration are presented, along with a discussion of its performance characteristics. The results of the measurements of water vapor absorption show that the continuum absorption in the wavelength range covered is 5-10% lower than previous measurements.

  11. The Correlation Analysis between Corneal Biomechanical Properties and the Surgically Induced Corneal High-Order Aberrations after Small Incision Lenticule Extraction and Femtosecond Laser In Situ Keratomileusis

    Directory of Open Access Journals (Sweden)

    Wenjing Wu

    2015-01-01

    Full Text Available Background. To investigate the correlation between corneal biomechanics and the surgically induced corneal high-order aberrations (HOAs after small incision lenticule extraction (SMILE and femtosecond laser in situ keratomileusis (FS-LASIK. Methods. A total of 150 right myopic eyes that underwent SMILE or FS-LASIK surgery were included in this retrospective study, 75 eyes in each group. The corneal hysteresis (CH and the corneal resistance factor (CRF with the corneal HOAs of the anterior, posterior, and total cornea were assessed preoperatively and three months postoperatively. Multivariate linear regression was applied to determine the correlations. Results. The preoperative CRF was significantly correlated with the induced 3rd–6th-order HOAs and spherical aberration of the anterior surface and the total cornea after SMILE and FS-LASIK surgeries (P<0.05, postoperatively. The CRF was significantly correlated with the induced vertical coma of the anterior and posterior surfaces and the total cornea after SMILE surgery (P<0.05. There was a significant correlation between the CRF and the induced posterior corneal horizontal coma after FS-LASIK surgery (P=0.013. Conclusions. The corneal biomechanics affect the surgically induced corneal HOAs after SMILE and FS-LASIK surgery, which may be meaningful for screening the patients preoperatively and optimizing the visual qualities postoperatively.

  12. Dry Eye after Small Incision Lenticule Extraction (SMILE) versus Femtosecond Laser-Assisted in Situ Keratomileusis (FS-LASIK) for Myopia: A Meta-Analysis.

    Science.gov (United States)

    Shen, Zeren; Zhu, Yanan; Song, Xiaohui; Yan, Jie; Yao, Ke

    2016-01-01

    To compare dry eye after small incision lenticule extraction (SMILE) and femtosecond laser-assisted LASIK (FS-LASIK) for correcting myopia. CENTRAL, Embase and PubMed were searched in November 2016. All randomized controlled trials (RCTs) and prospective cohorts that compared dry eye after SMILE with FS-LASIK were selected. Five cohorts and one RCT were identified for comparing dry eye after SMILE (291 eyes) and FS-LASIK (277 eyes). The pooled results revealed that the SMILE and FS-LASIK groups did not differ significantly in terms of Schirmer's I test (SIT) and tear film osmolarity (TFO) at any postoperative visits. By contrast, tear break up time (TBUT; p = 0.04 for one month, p LASIK group than in the SMILE group at follow-up. At six months postoperatively, TBUT and TFO values in both the SMILE and FS-LASIK groups and OSDI scores in the SMILE group returned to preoperative levels, but SIT values in both groups (p = 0.02 for the SMILE group and p LASIK group) and OSDI in the FS-LASIK group (p LASIK usually occurs transiently. SMILE does not show obvious superiority over FS-LASIK by exhibiting similar and acceptable objective parameters, and SMILE may have milder subjective symptoms.

  13. Corneal Backscatter Analysis by In Vivo Confocal Microscopy: Fellow Eye Comparison of Small Incision Lenticule Extraction and Femtosecond Laser-Assisted LASIK

    Directory of Open Access Journals (Sweden)

    Alper Agca

    2014-01-01

    Full Text Available Purpose. To evaluate and compare corneal backscatter from anterior stroma between small incision lenticule extraction (SMILE and femtosecond laser-assisted LASIK (femto-LASIK. Methods. A cohort of 60 eyes of 30 patients was randomized to receive SMILE in one eye and femto-LASIK in the fellow eye. In vivo confocal microscopy was performed at 1 week and 1, 3, and 6 months after surgery. The main outcome measurements were maximum backscattered intensity and the depth from which it was measured, the backscattered light intensity 30 μm below Bowman’s membrane at the flap interface and 150 μm below the superficial epithelium, and the number of refractive particles at the flap interface. Results. The mean backscattered light intensity (LI at all measured depths and the maximum backscattered LI were higher in the SMILE group than the femto-LASIK group at all postoperative visits. LI differences at 1 week and 1- and 3-month visits were statistically significant (P<0,05. LI differences at 6 months were not statistically significant. There was no difference in the number of refractive particles at the flap interface between the groups at any visit. Conclusions. SMILE results in increased backscattered LI in the anterior stroma when compared with femto-LASIK were evaluated.

  14. Two-years results of small-incision lenticule extraction and wavefront-guided laser in situ keratomileusis for Myopia.

    Science.gov (United States)

    Kobashi, Hidenaga; Kamiya, Kazutaka; Igarashi, Akihito; Takahashi, Masahide; Shimizu, Kimiya

    2018-03-01

    To compare the 2-years visual and refractive outcomes between small-incision lenticule extraction (SMILE) and wavefront-guided laser in situ keratomileusis (LASIK) in eyes with myopia and myopic astigmatism. Our retrospective case-control study examined 30 eyes of 30 patients with the manifest refraction spherical equivalent (MRSE) of -3.71 ± 1.83 dioptres (D) who underwent SMILE and 30 eyes of 30 patients with MRSE of -3.81 ± 1.40 D who underwent wavefront-guided LASIK. We assessed the 2-years clinical outcomes. Logarithm of the minimal angle of resolution (LogMAR)-corrected distance visual acuity (CDVA) was -0.23 ± 0.07 in the SMILE group and -0.24 ± 0.07 in the wavefront-guided LASIK group 2 years postoperatively (p = 0.82). Logarithm of the minimal angle of resolution-uncorrected distance visual acuity (UDVA) was -0.18 ± 0.09 and -0.15 ± 0.11 (p = 0.30, respectively). In the SMILE and wavefront-guided LASIK groups 2 years postoperatively, 100% and 73% of eyes, respectively, were within 0.5 D of the prompted MRSE correction (p = 0.005). Changes in the MRSE of -0.10 ± 0.30 D and -0.23 ± 0.51 D occurred from 3 months to 2 years (p = 0.40, respectively). We found a significant correlation between myopic regression and the changes in the keratometric readings from 3 months to 2 years after wavefront-guided LASIK (r = -0.48, p = 0.002), but not after SMILE (r = -0.004, p = 0.90). Small-incision lenticule extraction offers better refractive outcomes than wavefront-guided LASIK during a 2-years follow-up for the correction of myopia and myopic astigmatism. © 2017 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  15. Bacterial action of carbon dioxide laser radiation in experimental dental root canals

    International Nuclear Information System (INIS)

    Zakariasen, K.L.; Dederich, D.N.; Tulip, John; DeCoste, Sandra; Jensen, S.E.; Pickard, M.A.

    1986-01-01

    The ability of a carbon dioxide laser to sterilize the root canal of human teeth has been investigated. Three oral bacteria, Streptococcus sanguis, Streptococcus mutans, and Actinomyces viscosus, and three other bacteria, Bacillus cereus, Staphyloccus aureus, and Pseudomonoas aeruginosa were used as experimental organisms. Exposure of cells on glass slides to laser radiation showed there was little difference in the exposure required to kill these six organisms. Complete recovery of bacteria from the root canal was initially a problem and was only achieved when bacterial manipulations and removal were carried out in rapid succession, within 5 min of inoculation. However, the geometry of the instrumented canal and the laser alignment were major factors in achieving consistent cell death of oral bacteria in the root canals. Using sets of 10 teeth, four repeated exposures of 10 W for 1 s was found to sterilize 4 or more of the teeth

  16. Laser corrective surgery with fractional carbon dioxide laser following full-thickness skin grafts

    OpenAIRE

    Emily Forbat; Faisal R Ali; Raj Mallipeddi; Firas Al-Niaimi

    2017-01-01

    Full-thickness skin grafts (FTSGs) are frequently used to treat patients with burn injuries and to repair defects rendered by excisional (including Mohs) surgery. The evidence for corrective laser surgery after scar formation is well established. With regard to laser treatment of FTSG, the evidence is sparse. Laser treatment after FTSG is a novel concept, with minimal literature. We present a case series, one of the first to our knowledge, of the treatment of FTSG with fractional CO2 laser in...

  17. Laser corrective surgery with fractional carbon dioxide laser following full-thickness skin grafts

    Directory of Open Access Journals (Sweden)

    Emily Forbat

    2017-01-01

    Full Text Available Full-thickness skin grafts (FTSGs are frequently used to treat patients with burn injuries and to repair defects rendered by excisional (including Mohs surgery. The evidence for corrective laser surgery after scar formation is well established. With regard to laser treatment of FTSG, the evidence is sparse. Laser treatment after FTSG is a novel concept, with minimal literature. We present a case series, one of the first to our knowledge, of the treatment of FTSG with fractional CO2 laser in five patients after Mohs surgery.

  18. Outcomes of treatment of nine cases of recalcitrant severe hidradenitis suppurativa with carbon dioxide laser.

    Science.gov (United States)

    Madan, V; Hindle, E; Hussain, W; August, P J

    2008-12-01

    Hidradenitis suppurativa (HS) is a chronic and often a recalcitrant inflammatory skin condition. To present the results of carbon dioxide (CO2) laser treatment of recalcitrant HS in nine patients who had failed to improve on medical and other surgical treatments. HS lesions consisting of abscesses, sinuses and granulation tissue were completely excised using the cutting mode of a CO2 laser, leaving only healthy residual subcutaneous fat. The wounds were closed by primary intention where possible and left to granulate otherwise. Outcomes were determined by clinical review and questionnaire. Twenty-seven sites were treated in 19 sessions on nine patients. Seven procedures were performed under general anaesthesia and 12 under local. All patients rated their postoperative discomfort as less or equal to their preoperative state. Seven of the nine patients had complete remission for 12 months or longer after their last laser treatment and ceased all medications. High levels of patient satisfaction were reported with CO2 laser treatment. The main complication was axillary scar contracture in two patients but this was insufficient to limit limb movement. CO2 laser treatment should be considered as a treatment option in recalcitrant HS, where multiple medical treatments have been ineffective.

  19. Laser-produced plasma EUV source using a colloidal microjet target containing tin dioxide nanoparticles

    Science.gov (United States)

    Higashiguchi, Takeshi; Dojyo, Naoto; Sasaki, Wataru; Kubodera, Shoichi

    2006-10-01

    We realized a low-debris laser-produced plasma extreme ultraviolet (EUV) source by use of a colloidal microjet target, which contained low-concentration (6 wt%) tin-dioxide nanoparticles. An Nd:YAG laser was used to produce a plasma at the intensity on the order of 10^11 W/cm^2. The use of low concentration nanoparticles in a microjet target with a diameter of 50 μm regulated the neutral debris emission from a target, which was monitored by a silicon witness plate placed 30 cm apart from the source in a vacuum chamber. No XPS signals of tin and/or oxygen atoms were observed on the plate after ten thousand laser exposures. The low concentration nature of the target was compensated and the conversion efficiency (CE) was improved by introducing double pulses of two Nd:YAG lasers operated at 532 and 1064 nm as a result of controlling the micro-plasma characteristics. The EUV CE reached its maximum of 1.2% at the delay time of approximately 100 ns with the main laser intensiy of 2 x10^11 W/cm^2. The CE value was comparable to that of a tin bulk target, which, however, produced a significant amount of neutral debris.

  20. Fractional Carbon Dioxide Laser for Keratosis Pilaris: A Single-Blind, Randomized, Comparative Study

    Directory of Open Access Journals (Sweden)

    Vasanop Vachiramon

    2016-01-01

    Full Text Available Objective. Keratosis pilaris (KP is a common condition which can frequently be cosmetically disturbing. Topical treatments can be used with limited efficacy. The objective of this study is to evaluate the effectiveness and safety of fractional carbon dioxide (CO2 laser for the treatment of KP. Patients and Methods. A prospective, randomized, single-blinded, intraindividual comparative study was conducted on adult patients with KP. A single session of fractional CO2 laser was performed to one side of arm whereas the contralateral side served as control. Patients were scheduled for follow-up at 4 and 12 weeks after treatment. Clinical improvement was graded subjectively by blinded dermatologists. Patients rated treatment satisfaction at the end of the study. Results. Twenty patients completed the study. All patients stated that the laser treatment improved KP lesions. At 12-week follow-up, 30% of lesions on the laser-treated side had moderate to good improvement according to physicians’ global assessment (p=0.02. Keratotic papules and hyperpigmentation appeared to respond better than the erythematous component. Four patients with Fitzpatrick skin type V developed transient pigmentary alteration. Conclusions. Fractional CO2 laser treatment may be offered to patients with KP. Dark-skinned patients should be treated with special caution.

  1. Long-term results of carbon dioxide laser treatment of meatal condylomata acuminata

    DEFF Research Database (Denmark)

    Krogh, J; Beuke, H P; Miskowiak, J

    1990-01-01

    A group of 74 men who underwent carbon dioxide laser treatment of meatal condylomata were observed for an average of 18 months. The cure rate after 1 treatment of isolated meatal lesions was 78%; the presence of external lesions lowered the rate to 32% and additional external and urethral warts...... to 25%. Following multiple treatments all but 6 patients were cured; 83% of the recurrences developed within 3 months. One urethral and 6 meatal strictures occurred more than 3 months after treatment; 9 patients had a spraying stream many years after treatment and 2 complained of frequency....

  2. Welding uranium with a multikilowatt, continuous-wave, carbon dioxide laser welder

    International Nuclear Information System (INIS)

    Turner, P.W.; Townsend, A.B.

    1977-01-01

    A 15-kilowatt, continuous-wave carbon dioxide laser was contracted to make partial-penetration welds in 6.35-and 12.7-mm-thick wrought depleted uranium plates. Welding power and speed ranged from 2.3 to 12.9 kilowatts and from 21 to 127 millimeters per second, respectively. Results show that depth-to-width ratios of at least unity are feasible. The overall characteristics of the process indicate it can produce welds resembling those made by the electron-beam welding process

  3. Small incision lenticule extraction (SMILE) versus laser in-situ keratomileusis (LASIK): study protocol for a randomized, non-inferiority trial.

    Science.gov (United States)

    Ang, Marcus; Tan, Donald; Mehta, Jodhbir S

    2012-05-31

    Small incision lenticule extraction or SMILE is a novel form of 'flapless' corneal refractive surgery that was adapted from refractive lenticule extraction (ReLEx). SMILE uses only one femtosecond laser to complete the refractive surgery, potentially reducing surgical time, side effects, and cost. If successful, SMILE could potentially replace the current, widely practiced laser in-situ keratomileusis or LASIK. The aim of this study is to evaluate whether SMILE is non-inferior to LASIK in terms of refractive outcomes at 3 months post-operatively. Single tertiary center, parallel group, single-masked, paired-eye design, non-inferiority, randomized controlled trial. Participants who are eligible for LASIK will be enrolled for study after informed consent. Each participant will be randomized to receive SMILE and LASIK in each eye. Our primary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> -3.00 diopter (D)) at a tertiary eye center in terms of refractive predictability at 3 months post-operatively. Our secondary hypothesis (stated as null) in this non-inferiority trial would be that SMILE differs from LASIK in adults (>21 years old) with myopia (> -3.00 D) at a tertiary eye center in terms of other refractive outcomes (efficacy, safety, higher-order aberrations) at 3 months post-operatively. Our primary outcome is refractive predictability, which is one of several standard refractive outcomes, defined as the proportion of eyes achieving a postoperative spherical equivalent (SE) within ±0.50 D of the intended target. Randomization will be performed using random allocation sequence generated by a computer with no blocks or restrictions, and implemented by concealing the number-coded surgery within sealed envelopes until just before the procedure. In this single-masked trial, subjects and their caregivers will be masked to the assigned treatment in each eye. This novel

  4. Fractional Carbon Dioxide Laser and its Combination with Subcision in Improving Atrophic Acne Scars.

    Science.gov (United States)

    Nilforoushzadeh, Mohammad Ali; Faghihi, Gita; Jaffary, Fariba; Haftbaradaran, Elaheh; Hoseini, Sayed Mohsen; Mazaheri, Nafiseh

    2017-01-01

    Acne is a very common skin disease in which scars are seen in 95% of the patients. Although numerous treatments have been recommended, researchers are still searching for a single modality to treat the complication due to its variety in shape and depth. We compared the effects of fractional carbon dioxide (CO 2 ) laser alone and in combination with subcision in the treatment of atrophic acne scars. This clinical trial study was performed in Skin Diseases and Leishmaniasis Research Center (Isfahan, Iran) during 2011-2012. Eligible patients with atrophic acne scars were treated with fractional CO 2 laser alone (five sessions with 3-week interval) on the right side of the face and fractional CO 2 laser plus subcision (one session using both with four sessions of fractional CO 2 laser, with 3-week interval) on the left side. The subjects were visited 1, 2, and 6 months after the treatment. Patient satisfaction rate was analyzed using SPSS 20 software. The average of recovery rate was 54.7% using the combination method and 43.0% using laser alone ( P < 0.001). The mean patient satisfaction was significantly higher with the combination method than laser alone (6.6 ± 1.2 vs. 5.2 ± 1.8; P < 0.001). Bruising was only seen with the combination method and lasted for 1 week in 57.0% and for 2 weeks in 43.0%. Erythema was seen in both methods. Postinflammatory pigmentation and hyperpigmentation were associated with combination method. No persistent side effects were seen after 6 months. Using a combination of subcision and laser had suitable results regarding scar recovery and satisfaction rate.

  5. Use of the carbon dioxide laser in guided tissue regeneration wound healing in the beagle dog

    Science.gov (United States)

    Rossmann, Jeffrey A.; Parlar, Ates; Abdel-Ghaffar, Khaled A.; El-Khouli, Amr M.; Israel, Michael

    1996-04-01

    The concept of guided tissue regeneration (GTR) allowing cells from the periodontal ligament and alveolar bone to repopulate the treated root surface has shown the ability to obtain periodontal new attachment. Healing studies have also shown that conventional GTR therapy still does not exclude all the epithelium. This epithelial proliferation apically interferes with the establishment of the new connective tissue attachment to the root surface. The objective of this research study was to examine whether controlled de-epithelialization with the carbon dioxide laser during the healing phase after periodontal surgery, would retard the apical migration of the epithelium and thereby enhance the results obtained through guided tissue regeneration. Eight beagle dogs were used, the experimental side received de-epithelialization with the CO2 laser in conjunction with flap reflection and surgically created buccal osseous defects. Selected defects on each side were treated with ePTFE periodontal membranes. The laser de-epithelialization was repeated every 10 days until removal of the membranes. The control side received the same surgical treatment without laser application. This experimental design allowed histologic study of the new attachment obtained in defects treated with flap debridement with or without laser de-epithelialization and with or without ePTFE membranes. A statistical analysis was performed on the histometric data from 48 teeth in the 8 dogs after 4 months of healing. The results showed significant amounts of new attachment obtained from all four treatment modalities with no statistically significant differences for any one treatment. However, the trend towards enhanced regeneration with the combined treatment of laser and membrane vs. membrane alone or debridement alone was evident. The histologic analysis revealed a significant amount of newly formed `fat cementum' seen only on the laser treated teeth. This feature was the most remarkable finding of the

  6. Selective Removal of Residual Orthodontic Composite Using a Rapidly Scanned Carbon Dioxide Laser with Spectral Feedback

    Science.gov (United States)

    Hirasuna, Krista

    Background and Objective: Excessive heat accumulation within the tooth, incomplete removal of composite, and variable damage to the enamel are shortcomings of using conventional burs to remove residual orthodontic composite after debonding fixed appliances. The objective of this study was to determine if composite could be selectively removed from the enamel surface using a rapidly scanned carbon dioxide laser controlled by spectral feedback. Materials and Methods: A carbon dioxide laser operating at a wavelength of 9.3 microm with a pulse duration of 10-15 micros and a pulse repetition rate of ˜ 200 Hz was used to selectively remove composite from the buccal surfaces of 21 extracted teeth. GrenGloo(TM) composite was used to better visualize residual composite and the amount of enamel lost was measured with optical microscopy. A spectral feedback system utilizing a miniature spectrometer was used to control the laser scanning system. Pulpal temperature measurements were performed during composite removal to determine if there was excessive heat accumulation. Results: The amount of enamel lost averaged 22.7microm +/- 8.9 and 25.3 microm +/- 9.4 for removal at 3.8 and 4.2 J/cm2, respectively. An average maximum temperature rise of 1.9°C +/- 1.5 was recorded, with no teeth approaching the critical value of 5.5°C. The average time of composite removal was 19.3 +/- 4.1 seconds. Conclusions: Residual orthodontic composite can be rapidly removed from the tooth surface using a rapidly scanned CO2 laser with spectral feedback, with minimal temperature rise within the pulp and with minimal damage to the underlying enamel surface.

  7. Direct quantitative comparison of molecular responses in photodamaged human skin to fractionated and fully ablative carbon dioxide laser resurfacing.

    Science.gov (United States)

    Orringer, Jeffrey S; Sachs, Dana L; Shao, Yuan; Hammerberg, Craig; Cui, Yilei; Voorhees, John J; Fisher, Gary J

    2012-10-01

    Fractionated ablative laser resurfacing has become a widely used treatment modality. Its clinical results are often found to approach those of traditional fully ablative laser resurfacing. To directly compare the molecular changes that result from fractionated and fully ablative carbon dioxide (CO(2)) laser resurfacing in photodamaged human skin. Photodamaged skin of 34 adult volunteers was focally treated at distinct sites with a fully ablative CO(2) laser and a fractionated CO(2) laser. Serial skin samples were obtained at baseline and several time points after treatment. Real-time reverse transcriptase polymerase chain reaction technology and immunohistochemistry were used to quantify molecular responses to each type of laser treatment. Fully ablative and fractionated CO(2) laser resurfacing induced significant dermal remodeling and collagen induction. After a single treatment, fractionated ablative laser resurfacing resulted in collagen induction that was approximately 40% to 50% as pronounced as that induced by fully ablative laser resurfacing. The fundamental cutaneous responses that result from fully ablative and fractionated carbon dioxide laser resurfacing are similar but differ in magnitude and duration, with the fully ablative procedure inducing relatively greater changes including more pronounced collagen induction. However, the molecular data reported here provide substantial support for fractionated ablative resurfacing as an effective treatment modality for improving skin texture. © 2012 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  8. Molecular effects of fractional carbon dioxide laser resurfacing on photodamaged human skin.

    Science.gov (United States)

    Reilly, Michael J; Cohen, Marc; Hokugo, Akishige; Keller, Gregory S

    2010-01-01

    Objective To elucidate the sequential changes in protein expression that play a role in the clinically beneficial results seen with fractional carbon dioxide (CO(2)) laser resurfacing of the face and neck. Methods Nine healthy volunteers were recruited for participation from the senior author's facial plastic surgery practice. After informed consent was obtained, each volunteer underwent a 2-mm punch biopsy from a discrete area of infra-auricular neck skin prior to laser treatment. Patients then immediately underwent laser resurfacing of photodamaged face and neck skin at a minimal dose (30 W for 0.1 second) with the Pixel Perfect fractional CO(2) laser. On completion of the treatment, another biopsy specimen was taken adjacent to the first site. Additional biopsy specimens were subsequently taken from adjacent skin at 2 of 3 time points (day 7, day 14, or day 21). RNA was extracted from the specimens, and reverse transcriptase-polymerase chain reaction and protein microarray analysis were performed. Comparisons were then made between time points using pairwise comparison testing. Results We found statistically significant changes in the gene expression of several matrix metalloproteinases (MMPs). The data demonstrate a consistent up-regulation of MMPs 1, 3, 9, and 13, all of which have been previously reported for fully ablative CO(2) laser resurfacing. There was also a statistically significant increase in MMP-10 and MMP-11 levels in this data set. Conclusion This study suggests that the molecular mechanisms of action are similar for both fractional and fully ablative CO(2) laser resurfacing.

  9. Small Incision Lenticule Extraction (SMILE versus Femtosecond Laser-Assisted In Situ Keratomileusis (FS-LASIK for Myopia: A Systematic Review and Meta-Analysis.

    Directory of Open Access Journals (Sweden)

    Zeren Shen

    Full Text Available The goal of this study was to compare small incision lenticule extraction (SMILE with femtosecond laser-assisted in situ keratomileusis (FS-LASIK for treating myopia.The CENTRAL, EMBASE, PubMed databases and a Chinese database (SinoMed were searched in May of 2016. Twelve studies with 1,076 eyes, which included three randomized controlled trials (RCTs and nine cohorts, met our inclusion criteria. The overall quality of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE working group framework. Data were extracted and analysed at three to six months postoperatively. Primary outcome measures included a loss of one or more lines of best spectacle corrected visual acuity (BSCVA, uncorrected visual acuity (UCVA of 20/20 or better, mean logMAR UCVA, postoperative mean spherical equivalent (SE and postoperative refraction within ±1.0 D of the target refraction. Secondary outcome measures included ocular surface disease index (OSDI, tear breakup time (TBUT and Schirmer's 1 test (S1T as dry eye parameters, along with corneal sensitivity.The overall quality of evidence was considered to be low to very low. Pooled results revealed no significant differences between the two groups with regard to a loss of one or more lines in the BSCVA (OR 1.71; 95% CI: 0.81, 3.63; P = 0.16, UCVA of 20/20 or better (OR 0.71; 95% CI: 0.44, 1.15; P = 0.16, logMAR UCVA (MD 0.00; 95% CI: -0.03, 0.04; P = 0.87, postoperative refractive SE (MD -0.00; 95% CI: -0.05, 0.05; P = 0.97 or postoperative refraction within ±1.0 D of the target refraction (OR 0.78; 95% CI: 0.22, 2.77; P = 0.70 within six months postoperatively. The pooled analysis also indicated that the FS-LASIK group suffered more severely from dry eye symptoms (OSDI; MD -6.68; 95% CI: -11.76, -2.00; P = 0.006 and lower corneal sensitivity (MD 12.40; 95% CI: 10.23, 14.56; P < 0.00001 at six months postoperatively.In conclusion, both FS-LASIK and SMILE are safe

  10. Small Incision Lenticule Extraction (SMILE) versus Femtosecond Laser-Assisted In Situ Keratomileusis (FS-LASIK) for Myopia: A Systematic Review and Meta-Analysis

    Science.gov (United States)

    Shen, Zeren; Shi, Keda; Yu, Yinhui; Yu, Xiaoning; Lin, Yuchen; Yao, Ke

    2016-01-01

    Purpose The goal of this study was to compare small incision lenticule extraction (SMILE) with femtosecond laser-assisted in situ keratomileusis (FS-LASIK) for treating myopia. Methods The CENTRAL, EMBASE, PubMed databases and a Chinese database (SinoMed) were searched in May of 2016. Twelve studies with 1,076 eyes, which included three randomized controlled trials (RCTs) and nine cohorts, met our inclusion criteria. The overall quality of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) working group framework. Data were extracted and analysed at three to six months postoperatively. Primary outcome measures included a loss of one or more lines of best spectacle corrected visual acuity (BSCVA), uncorrected visual acuity (UCVA) of 20/20 or better, mean logMAR UCVA, postoperative mean spherical equivalent (SE) and postoperative refraction within ±1.0 D of the target refraction. Secondary outcome measures included ocular surface disease index (OSDI), tear breakup time (TBUT) and Schirmer’s 1 test (S1T) as dry eye parameters, along with corneal sensitivity. Results The overall quality of evidence was considered to be low to very low. Pooled results revealed no significant differences between the two groups with regard to a loss of one or more lines in the BSCVA (OR 1.71; 95% CI: 0.81, 3.63; P = 0.16), UCVA of 20/20 or better (OR 0.71; 95% CI: 0.44, 1.15; P = 0.16), logMAR UCVA (MD 0.00; 95% CI: -0.03, 0.04; P = 0.87), postoperative refractive SE (MD -0.00; 95% CI: -0.05, 0.05; P = 0.97) or postoperative refraction within ±1.0 D of the target refraction (OR 0.78; 95% CI: 0.22, 2.77; P = 0.70) within six months postoperatively. The pooled analysis also indicated that the FS-LASIK group suffered more severely from dry eye symptoms (OSDI; MD -6.68; 95% CI: -11.76, -2.00; P = 0.006) and lower corneal sensitivity (MD 12.40; 95% CI: 10.23, 14.56; P LASIK and SMILE are safe, effective and predictable surgical

  11. Measurement of uranium dioxide thermophysical properties by the laser flash method

    International Nuclear Information System (INIS)

    Grossi, Pablo Andrade; Ferreira, Ricardo Alberto Neto; Camarano, Denise das Merces; Andrade, Roberto Marcio de

    2009-01-01

    The evaluation of the thermophysical properties of uranium dioxide (UO 2 ), including a reliable uncertainty assessment, are required by the nuclear reactor design. These important information are used by thermohydraulic codes to define operational aspects and to assure the safety, when analyzing various potential situations of accident. The laser flash method had become the most popular method to measure the thermophysical properties of materials. Despite its several advantages, some experimental obstacles have been found due to the difficulty to obtain experimentally the ideals initial and boundary conditions required by the original method. An experimental apparatus and a methodology for estimating uncertainties of thermal diffusivity, thermal conductivity and specific heat measurements based on the laser flash method are presented. A stochastic thermal diffusion modeling has been developed and validated by standard samples. Inverse heat conduction problems (IHCPs) solved by finite volumes technique were applied to the measurement process with real initial and boundary conditions, and Monte Carlo Method was used for propagating the uncertainties. The main sources of uncertainty were due to: pulse time, laser power, thermal exchanges, absorptivity, emissivity, sample thickness, specific mass and dynamic influence of temperature measurement system. As results, mean values and uncertainties of thermal diffusivity, thermal conductivity and specific heat of UO 2 are presented. (author)

  12. Cell spreading on titanium dioxide film formed and modified with aerosol beam and femtosecond laser

    Energy Technology Data Exchange (ETDEWEB)

    Shinonaga, Togo, E-mail: togo@jwri.osaka-u.ac.jp [Graduate School of Engineering, Osaka University, 1-1 Yamadaoka, Suita, Osaka 565-0871 (Japan); Tsukamoto, Masahiro [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan); Nagai, Akiko; Yamashita, Kimihiro; Hanawa, Takao [Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, 2-3-10 Kanda-Surugadai, Chiyoda-ku, Tokyo 101-0062 (Japan); Matsushita, Nobuhiro [Materials and Structures Laboratory, Tokyo Institute of Technology, 4259 Nagatsuta-cho, Midori-ku, Yokohama, Kanagawa 226-8503 (Japan); Xie, Guoqiang [Institute for Materials Research, Tohoku University, 2-1-1 Karahira, Aoba-ku, Sendai, Miyagi 980-8577 (Japan); Abe, Nobuyuki [Joining and Welding Research Institute, Osaka University, 11-1 Mihogaoka, Ibaraki, Osaka 567-0047 (Japan)

    2014-01-01

    Titanium (Ti) is widely used in biomaterials because of its excellent anti-corrosion properties and high strength. However, Ti has no biological function, so its bioactivity must be improved. Coating a titanium dioxide (TiO{sub 2}) film on a Ti plate surface has been shown to improve the biocompatibility of Ti plates. If periodic nanostructures were formed on the film surface, the direction of cell spreading might be controlled by the direction of the grooves. Controlling cell spreading on biomaterials would contribute to the creation of advanced biomaterials. In this paper, a TiO{sub 2} film was formed on a Ti plate with an aerosol beam composed of sub micron-sized TiO{sub 2} particles and helium gas. Periodic nanostructures, lying perpendicular to the laser electric field polarization vector, were formed on the film by scanning the femtosecond laser focusing spot. The period and height of the periodic nanostructures were about 230 nm and 150 nm, respectively. In a cell test, cell spreading was observed along the grooves of the periodic nanostructures; in contrast, cell spreading did not show a definite direction on TiO{sub 2} a film without periodic nanostructures. These results suggest that the direction of cell spreading on the film can be controlled by periodic nanostructure formation generated using a femtosecond laser.

  13. Cell spreading on titanium dioxide film formed and modified with aerosol beam and femtosecond laser

    International Nuclear Information System (INIS)

    Shinonaga, Togo; Tsukamoto, Masahiro; Nagai, Akiko; Yamashita, Kimihiro; Hanawa, Takao; Matsushita, Nobuhiro; Xie, Guoqiang; Abe, Nobuyuki

    2014-01-01

    Titanium (Ti) is widely used in biomaterials because of its excellent anti-corrosion properties and high strength. However, Ti has no biological function, so its bioactivity must be improved. Coating a titanium dioxide (TiO 2 ) film on a Ti plate surface has been shown to improve the biocompatibility of Ti plates. If periodic nanostructures were formed on the film surface, the direction of cell spreading might be controlled by the direction of the grooves. Controlling cell spreading on biomaterials would contribute to the creation of advanced biomaterials. In this paper, a TiO 2 film was formed on a Ti plate with an aerosol beam composed of sub micron-sized TiO 2 particles and helium gas. Periodic nanostructures, lying perpendicular to the laser electric field polarization vector, were formed on the film by scanning the femtosecond laser focusing spot. The period and height of the periodic nanostructures were about 230 nm and 150 nm, respectively. In a cell test, cell spreading was observed along the grooves of the periodic nanostructures; in contrast, cell spreading did not show a definite direction on TiO 2 a film without periodic nanostructures. These results suggest that the direction of cell spreading on the film can be controlled by periodic nanostructure formation generated using a femtosecond laser.

  14. Hydroxyapatite coatings on titanium dioxide thin films prepared by pulsed laser deposition method

    International Nuclear Information System (INIS)

    Suda, Yoshiaki; Kawasaki, Hiroharu; Ohshima, Tamiko; Nakashima, Shouta; Kawazoe, Syuichi; Toma, Tetsuya

    2006-01-01

    Hydroxyapatite (HAp) coated on titanium dioxide (TiO 2 ) thin films has been developed to supplement the defects of both TiO 2 and HAp. Thin films have been prepared by pulsed laser deposition (PLD) method using HAp and HAp(10%) + TiO 2 targets. X-ray diffraction (XRD) shows that there are many small peaks of Ca 1 0(PO 4 ) 6 (OH) 2 crystal, and no impurity other than HAp is detected in HAp films prepared using pure HAp target. The composition ratio of the film was analyzed by X-ray photoelectron spectroscopy (XPS). HAp coatings on TiO 2 thin films have been prepared using HAp(10%) + TiO 2 targets. XRD and XPS measurements suggest that crystalline HAp + TiO 2 thin films are obtained by the PLD method using HAp(10%) + TiO 2 target

  15. Effect of Carbon Dioxide Laser on Increasing Vestibular Depth in Cleft Lip and Palate Patients.

    Science.gov (United States)

    Yassaei, Sogra; Aghili, Hossein; Azam, Alireza Navab; Moghadam, Mahjobeh Gholdani; Safari, Isa

    2017-09-01

    Shallow upper buccal sulcus deformity in cleft lip and palate patients is one of the common secondary deformities after primary cleft lip and palate repair; this deformity may prevent or complicate orthodontic and prosthodontic procedures causing aesthetic and functional problems. A number of methods are described to increase the anterior maxillary sulcus in these patients. This study assessed the use of a carbon dioxide laser (CO 2 ) to increase the sulcus depth. Fifteen patients with cleft lip and palate (eight unilateral and seven bilateral) were studied. The surgical procedure was performed using CO 2 laser. The vestibular depth and lip length were measured at three time points namely before surgery (T0), 1 week following surgery (T1), and 4 months following surgery (T2). After data collection, statistical analyses were done using PASW ® version 18 SPSS. The mean values of vestibular depth were 9.46 ± 1.92, 13.83 ± 1.88, and 13.23 ± 1.76 mm for T0, T1, and T2, respectively. The vestibular depth significantly increased after 4 months of follow-up (p = 0.001). The mean amount of vestibular depth gain was not significantly different in unilateral and bilateral cleft groups (p = 0.908). The mean value of upper lip length increased by a mean of 1.23 mm and was statistically significant (p = 0.001). Upper buccal sulcus reconstruction with CO 2 laser provides successful and stable results. CO 2 laser application is suggested as an alternative to conventional vestibuloplasty.

  16. Hypertrophic Scarring of the Neck Following Ablative Fractional Carbon Dioxide Laser Resurfacing

    Science.gov (United States)

    Avram, Mathew M.; Tope, Whitney D.; Yu, Thomas; Szachowicz, Edward; Nelson, J. Stuart

    2009-01-01

    Background Ablative fractional carbon dioxide (CO2) laser treatments have gained popularity due to their efficacy, shortened downtime, and decreased potential for scarring in comparison to traditional ablative CO2 resurfacing. To date, scarring with fractional CO2 lasers has not been reported. Objective Five patients treated with the same fractional CO2 laser technology for photodamage of the neck were referred to our practices 1–3 months after treatment. Each patient developed scarring. Of the five cases, two are discussed in detail. The first was treated under general anesthesia on the face and anterior neck at a pulse energy of 30 mJ (859 μm depth) with 25% coverage. Eleven days after treatment, three non-healing areas along the horizontal skin folds of the anterior neck were noted. At 2 weeks after CO2 ablative fractional resurfacing, these areas had become thickened. These raised areas were treated with a non-ablative fractionated 1,550 nm laser to modify the wound healing milieu. One week later, distinct firm pale papules in linear arrays with mild hypopigmentation had developed along involved neck skin folds. Skin biopsy was performed. For the second patient, the neck was treated at a pulse energy of 20 mJ (630 μm depth) with 30% coverage of the exposed skin, with a total treatment energy of 5.0 kJ. Minimal crusting was noted on the neck throughout the initial healing phase of 2 weeks. She then experienced tightness on her neck. Approximately 3 weeks after treatment, she developed multiple vertical and horizontal hypertrophic scars (HS). Results Histopathology for the first case confirmed the presence of a hypertrophic scar. The papules in this case completely resolved with mild residual hypopigmentation after treatment with topical corticosteroids. HS failed to resolve in the second case to date after 1 month. Conclusion As with traditional ablative CO2 laser resurfacing, HS is a potential complication of ablative fractional CO2 laser resurfacing

  17. Ablative Fractional 10 600 nm Carbon Dioxide Laser Versus Non-ablative Fractional 1540 nm Erbium-Glass Laser in Egyptian Post-acne Scar patients.

    Science.gov (United States)

    Elsaie, Mohamed L; Ibrahim, Shady M; Saudi, Wael

    2018-01-01

    Introduction: Non-ablative fractional erbium-doped glass 1540 nm and fractional ablative 10600 nm carbon dioxide lasers are regarded as effective modalities for treating acne atrophic scars. In this study, we aimed to compare the effectiveness of fractional CO 2 laser and fractional nonablative 1540 nm erbium doped glass laser in treating post acne atrophic scars in Egyptian patients. Methods: Fifty-eight patients complaining of moderate and severe acne atrophic scars were randomly divided into 2 groups of 29 patients each. Both groups were subjected to 4 treatment sessions with 3 weeks interval and were followed up for 3 months. In group A, enrolled patient sreceived C2 laser, while in group B, patients were treated with 1540 nm erbium glass fractional laser. Results: Clinical assessment revealed that the mean grades of progress and improvement were higher with fractional 10600 nm CO2 laser but with non-significant difference between both treatments ( P = 0.1). The overall patients' satisfaction with both lasers were not significantly different ( P = 0.44). Conclusion: Both fractional ablative CO2 and fractional non-ablative erbium glass lasers are good modalities for treating acne scars with a high efficacy and safety profile and good patient satisfaction. The fractional ablative laser showed higher efficacy while non-ablative laser offered less pain and shorter downtime.

  18. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism

    Directory of Open Access Journals (Sweden)

    Li-Kun Xia

    2018-03-01

    Full Text Available AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs, contrast sensitivity (CS and dry eye parameters after small incision lenticule extraction (SMILE and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE of -8.11±1.09 diopters (D received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI and tear break-up time (TBUT were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA postoperatively was achieved at 1mo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=0.13. The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00, and 0.14 D in the SMILE group (t=0.54, P=0.59 from 1mo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00, but the coma root mean square (RMS was higher in the SMILE group (0.59±0.26 than in the FS-LASIK group (0.29±0.14, P=0.00. The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at 1mo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS-LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long

  19. Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism.

    Science.gov (United States)

    Xia, Li-Kun; Ma, Jing; Liu, He-Nan; Shi, Ce; Huang, Qing

    2018-01-01

    To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at 1mo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant ( t =-1.59, P =0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group ( t =5.76, P =0.00), and 0.14 D in the SMILE group ( t =0.54, P =0.59) from 1mo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group ( P =0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P =0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at 1mo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. Both SMILE and wavefront-guided FS-LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better

  20. Fractional ablative carbon dioxide laser resurfacing for skin rejuvenation and acne scars in Asians.

    Science.gov (United States)

    Chan, Nicola P Y; Ho, Stephanie G Y; Yeung, Chi K; Shek, Samantha Y N; Chan, Henry H

    2010-11-01

    Ablative fractional resurfacing (AFR) is a new modality for photorejuvenation and acne scars which combines carbon dioxide (CO₂) laser ablation with fractional photothermolysis. The objective is to evaluate the efficacy and side effects of a new fractional CO₂ ablative device (Fraxel Re:pair) for skin rejuvenation and acne scars in Asians. Nine patients underwent one full-face treatment. The energy levels ranged from 30-70 mJ with coverage between 30% and 45%. Improvement in skin texture, laxity, wrinkles, enlarged pores, overall pigmentation irregularity, and adverse effects were assessed up to 6 months post-treatment. Standardized photographs using the Canfield Visia CR system® were assessed by two independent observers. Subjective improvement was assessed by patient questionnaires. Nine Chinese patients (skin types III and IV, mean age 44.8) were included. Statistically significant improvements were seen for skin texture, skin laxity, wrinkles, enlarged pores, and acne scars. The post-inflammatory hyperpigmentation rate was 55.5% and 11.1% at 1 and 6 months post-treatment, respectively. Eighty-six percent of patients were overall satisfied to very satisfied with the treatment. Ablative fractional CO₂ laser resurfacing was overall safe and effective for skin rejuvenation and acne scars in Asians. However, in view of the high post-inflammatory rate and the statistically significant but only mild to moderate improvement after a single treatment as observed in this study, there is a need to review the current role of fractional ablative CO₂ laser treatment as compared to fractional non-ablative for skin rejuvenation and acne scar treatment in Asians. © 2010 Wiley-Liss, Inc.

  1. Progress on High-Energy 2-micron Solid State Laser for NASA Space-Based Wind and Carbon Dioxide Measurements

    Science.gov (United States)

    Singh, Upendra N.

    2011-01-01

    Sustained research efforts at NASA Langley Research Center during last fifteen years have resulted in significant advancement of a 2-micron diode-pumped, solid-state laser transmitter for wind and carbon dioxide measurements from ground, air and space-borne platforms. Solid-state 2-micron laser is a key subsystem for a coherent Doppler lidar that measures the horizontal and vertical wind velocities with high precision and resolution. The same laser, after a few modifications, can also be used in a Differential Absorption Lidar system for measuring atmospheric CO2 concentration profiles. Researchers at NASA Langley Research Center have developed a compact, flight capable, high energy, injection seeded, 2-micron laser transmitter for ground and airborne wind and carbon dioxide measurements. It is capable of producing 250 mJ at 10 Hz by an oscillator and one amplifier. This compact laser transmitter was integrated into a mobile trailer based coherent Doppler wind and CO2 DIAL system and was deployed during field measurement campaigns. This paper will give an overview of 2-micron solid-state laser technology development and discuss results from recent ground-based field measurements.

  2. Influence of instrument conditions on the evaporation behavior of uranium dioxide with UV laser-assisted atom probe tomography

    International Nuclear Information System (INIS)

    2015-01-01

    Atom probe tomography (APT) provides the ability to detect subnanometer chemical variations spatially with high accuracy. Due to its ability to spatially characterize chemistry in non-conducting materials, such as oxides, provides the opportunity to characterize stoichiometry, which strongly is tied to material performance. However, accuracy has been correlated with instrument run parameters. A systematic study of the effect of laser energy, temperature, and detection rate is performed on the evaporation behavior of a model oxide, uranium dioxide (UO 2 ). Modifying the detection rate and temperature did not affect its evaporation behavior as laser energy. It was discovered that three laser evaporation regimes are present in UO 2 . Very low laser energy produces a behavior similar to DC-field evaporation, moderate laser energy produces the desired laser assisted field evaporation and high laser energy produces thermal effects in the evaporation behavior. Laser energy had the greatest impact on evaporation and the optimal instrument condition for UO 2 was determined to be 50K, 10 pJ laser energy, 0.3% detection rate, and a 100 kHz repetition rate. These conditions provide the best combination of mass resolution, accurate stoichiometry, and evaporation behavior.

  3. Application of the UV laser printing technique to soft gelatin capsules containing titanium dioxide in the shells.

    Science.gov (United States)

    Hosokawa, Akihiro; Kato, Yoshiteru

    2012-03-01

    The purpose of this study was to examine application of ultraviolet (UV) laser irradiation to printing soft gelatin capsules containing titanium dioxide (TiO(2)) in the shells and to study effect of UV laser power on the color strength of printing on the soft gelatin capsules. Size 6 Oval type soft gelatin capsules of which shells contained 0.685% TiO(2) and 0.005% ferric dioxide were used in this study. The capsules were irradiated pulsed UV laser at a wavelength 355 nm. The color strength of the printed capsules was determined by a spectrophotometer as total color difference (dE). The soft gelatin capsules which contained TiO(2) in the shells could be printed gray by the laser. Many black particles, which were associated with the printing, were formed at the colored parts of the shells. It was found that there were two inflection points in relationship between output laser energy of a pulse and dE. Below the lower point, the capsules were not printed. From the lower point to the upper point, the capsules were printed gray and total color difference of the printing increased linearly in proportion with the output laser energy. Beyond the upper point, total color difference showed saturation because of micro-bubbles formation at the laser irradiated spot. Soft gelatin capsules containing TiO(2) in the shells could be performed stable printing using the UV laser printing technique. Color strength of the printing could be controlled by regulating the laser energy between the two inflection points.

  4. Excellent Aesthetic and Functional Outcome After Fractionated Carbon Dioxide Laser Skin Graft Revision Surgery: Case Report and Review of Laser Skin Graft Revision Techniques.

    Science.gov (United States)

    Ho, Derek; Jagdeo, Jared

    2015-11-01

    Skin grafts are utilized in dermatology to reconstruct a defect secondary to surgery or trauma of the skin. Common indications for skin grafts include surgical removal of cutaneous malignancies, replacement of tissue after burns or lacerations, and hair transplantation in alopecia. Skin grafts may be cosmetically displeasing, functionally limiting, and significantly impact patient's quality-of-life. There is limited published data regarding skin graft revision to enhance aesthetics and function. Here, we present a case demonstrating excellent aesthetic and functional outcome after fractionated carbon dioxide (CO2) laser skin graft revision surgery and review of the medical literature on laser skin graft revision techniques.

  5. Uranium dioxide thermal characterization by the flash laser method from 23 Celsius to 175 Celsius

    International Nuclear Information System (INIS)

    Faeda, K.C.M.; Lameiras, F.S.; Carneiro, L.S.S.; Camarano, D.M.; Ferreira, R.A.N.

    2010-01-01

    The Laser Flash Method has become one of the most common techniques for measuring thermal diffusivity and conductivity in solids and liquids. This method is recognized by INMETRO as standard to be used in Brazil for measuring thermophysical properties of materials, such as metals, carbon composites, ceramics, and also nuclear materials. This article describes the experimental bench of the LMPT-Laboratorio de Medicao de Propriedades Termofisicas de Combustiveis Nucleares e Materiais of the CDTN-Centro de Desenvolvimento da Tecnologia Nuclear, (LMPT), as well as the mathematical model developed based on this method. The obtained results for the thermal diffusivity and for the thermal conductivity of uranium dioxide (U0 2 ) pellets in the temperature range from 25 deg to 175 deg C, are discussed and compared with the literature data. The estimative of the input quantities uncertainty of the mathematical model was determined according to ISO - BIPM-Guide to the Expression of Uncertainty in Measurement and the Monte Carlo Method was used to estimate of the output quantities uncertainty (thermal diffusivity and thermal conductivity). Additionally the results of the x-rays of these pellets are presented. (author)

  6. Imprinting on empty hard gelatin capsule shells containing titanium dioxide by application of the UV laser printing technique.

    Science.gov (United States)

    Hosokawa, Akihiro; Kato, Yoshiteru; Terada, Katsuhide

    2014-08-01

    The purpose of this study was to examine the application of ultraviolet (UV) laser irradiation to printing hard gelatin capsule shells containing titanium dioxide (TiO2) and to clarify how the color strength of the printing by the laser could be controlled by the power of the irradiated laser. Hard gelatin capsule shells containing 3.5% TiO2 were used in this study. The capsules were irradiated with pulsed UV laser at a wavelength of 355 nm. The color strength of the printed capsule was determined by a spectrophotometer as total color difference (dE). The capsules could be printed gray by the UV laser. The formation of many black particles which were agglomerates of oxygen-defected TiO2 was associated with the printing. In the relationship between laser peak power of a pulse and dE, there were two inflection points. The lower point was the minimal laser peak power to form the black particles and was constant regardless of the dosage forms, for example film-coated tablets, soft gelatin capsules and hard gelatin capsules. The upper point was the minimal laser peak power to form micro-bubbles in the shells and was variable with the formulation. From the lower point to the upper point, the capsules were printed gray and the dE of the printing increased linearly with the laser peak power. Hard gelatin capsule shells containing TiO2 could be printed gray using the UV laser printing technique. The color strength of the printing could be controlled by regulating the laser energy between the two inflection points.

  7. Low-debris, efficient laser-produced plasma extreme ultraviolet source by use of a regenerative liquid microjet target containing tin dioxide (SnO2) nanoparticles

    Science.gov (United States)

    Higashiguchi, Takeshi; Dojyo, Naoto; Hamada, Masaya; Sasaki, Wataru; Kubodera, Shoichi

    2006-05-01

    We demonstrated a low-debris, efficient laser-produced plasma extreme ultraviolet (EUV) source by use of a regenerative liquid microjet target containing tin-dioxide (SnO2) nanoparticles. By using a low SnO2 concentration (6%) solution and dual laser pulses for the plasma control, we observed the EUV conversion efficiency of 1.2% with undetectable debris.

  8. Low-debris, efficient laser-produced plasma extreme ultraviolet source by use of a regenerative liquid microjet target containing tin dioxide (SnO2) nanoparticles

    International Nuclear Information System (INIS)

    Higashiguchi, Takeshi; Dojyo, Naoto; Hamada, Masaya; Sasaki, Wataru; Kubodera, Shoichi

    2006-01-01

    We demonstrated a low-debris, efficient laser-produced plasma extreme ultraviolet (EUV) source by use of a regenerative liquid microjet target containing tin-dioxide (SnO 2 ) nanoparticles. By using a low SnO 2 concentration (6%) solution and dual laser pulses for the plasma control, we observed the EUV conversion efficiency of 1.2% with undetectable debris

  9. Fractional ablative carbon dioxide laser followed by topical sodium stibogluconate application: A treatment option for pediatric cutaneous leishmaniasis.

    Science.gov (United States)

    Hilerowicz, Yuval; Koren, Amir; Mashiah, Jacob; Katz, Oren; Sprecher, Eli; Artzi, Ofir

    2018-05-01

    Leishmaniasis is a protozoan zoonotic parasitic infection with cutaneous, mucocutaneous, and visceral manifestations. Israel is endemic for cutaneous leishmaniasis, which is a self-limited disease but is associated with scarring, which is often a source of psychological and social burden for patients. Scars can be especially devastating for children and teenagers. A wide range of physical and medical approaches is used to treat cutaneous leishmaniasis, among which intralesional injections of sodium stibogluconate rank among the most frequently used. Unfortunately, despite being effective, this therapeutic modality can be very painful. Fractional ablative laser creates a controlled mesh-like pattern of tissue ablation in the skin that promotes dermal remodeling and collagen production while at the same time facilitating enhanced delivery of topically applied medications. Patients were treated with fractional ablative carbon dioxide laser followed by immediate topical application of sodium stibogluconate. All children were diagnosed with cutaneous leishmaniasis prior to treatment initiation.. Ten children were treated. One leishmania tropica-positive girl failed to respond. The other nine patients achieved clinical cure and demonstrated good to excellent final cosmesis. Self-rated patient satisfaction and tolerance were high No adverse effects were observed or reported during treatment. Fractional ablative carbon dioxide laser followed by topical sodium stibogluconate application appears to be a safe and promising treatment for cutaneous leishmaniasis infection in children. Future controlled studies are required to validate these findings and compare this technique with traditional approaches. © 2018 Wiley Periodicals, Inc.

  10. The Effect of Neodymium: Yttrium Aluminum Garnet and Fractional Carbon Dioxide Lasers on Alopecia Areata: A Prospective Controlled Clinical Trial.

    Science.gov (United States)

    Yalici-Armagan, Basak; Elcin, Gonca

    2016-04-01

    Effective treatment options for alopecia areata (AA) are missing. Whether lasers might be effective is a topic of debate. We aimed to evaluate whether neodymium: yttrium aluminum garnet (Nd:YAG) or fractional carbon dioxide lasers might stimulate the development of new hair. Thirty-two patients who had long-standing and treatment refractory diseases were recruited for the study. Three different patches on the scalp were selected, 1 of which served as control. The mean outcome measure was the hair count, which was calculated with the digital phototrichogram. Response was defined as at least 25% increase in the mean hair count at the treated patch compared with the control patch. At the end of the study, there was no statistically significant difference in the mean hair count for the 3 patches. In 7 of 32 patients (22%), an increase in the mean hair count was observed on the whole scalp including the control patch, which resulted in an improved Severity of Alopecia Tool (SALT) score. We have observed that Nd:YAG or fractional carbon dioxide lasers did not increase the mean hair count on the treated AA patches when compared with the control patch. However, an SALT score improvement in 22% of the patients suggested spontaneous remission.

  11. Combination of Q-switched and quasi long-pulsed 1064-nm Nd:YAG laser, non-ablative 1450-nm diode laser, and ablative 10 600-nm carbon dioxide fractional laser for enlarged pores.

    Science.gov (United States)

    Cho, Sung Bin; Noh, Seongmin; Lee, Sang Ju; Kang, Jin Moon; Kim, Young Koo; Lee, Ju Hee

    2010-07-01

    Currently, there is no gold standard for the treatment of enlarged facial pores. In this report, we describe a patient with enlarged nasal pores which were treated with a combination of a non-ablative 1450-nm diode laser, a Q-switched and quasi long-pulsed 1064-nm Nd:YAG laser, and an ablative 10 600-nm carbon dioxide fractional laser system. Four months after the final treatment, the condition of the patient's pores had markedly improved, and the patient was satisfied with the results.

  12. The inverted Batman incision: a new incision in transcolumellar incision for open rhinoplasty.

    Science.gov (United States)

    Nakanishi, Yuji; Nagasao, Tomohisa; Shimizu, Yusuke; Miyamoto, Junpei; Fukuta, Keizo; Kishi, Kazuo

    2013-12-01

    Columellar and nostril shapes often present irregularity after transcolumellar incision for open rhinoplasty, because of the contracture of the incised wound. The present study introduces a new technique to prevent this complication, and verifies its efficacy in improving cosmetic appearance. In our new method, a zig-zag incision with three small triangular flaps is made on the columella and in the pericolumellar regions of the bilateral nostril rims. Since the shape of the incision resembles the contour of an inverted "batman", we term our new method the "Inverted Batman" incision. To verify the effectiveness of the Inverted Batman incision, aesthetic evaluation was conducted for 21 patients operated on using the conventional transcolumellar incision (Conventional Group) and 19 patients operated on using the Inverted Batman incision (Inverted Batman Group). The evaluation was performed by three plastic surgeons, using a four-grade scale to assess three separate items: symmetry of bilateral soft triangles, symmetry of bilateral margins of the columella, and evenness of the columellar surface. The scores of the two groups for these three items were compared using a non-parametric test (Mann-Whitney U-test). With all three items, the Inverted Batman group patients present higher scores than Conventional Group patients. The Inverted Batman incision is effective in preserving the correct anatomical structure of the columella, soft triangle, and nostril rims. Hence, we recommend the Inverted Batman incision as a useful technique for open rhinoplasty.

  13. Minimal abdominal incisions

    Directory of Open Access Journals (Sweden)

    João Carlos Magi

    2017-04-01

    Full Text Available Minimally invasive procedures aim to resolve the disease with minimal trauma to the body, resulting in a rapid return to activities and in reductions of infection, complications, costs and pain. Minimally incised laparotomy, sometimes referred to as minilaparotomy, is an example of such minimally invasive procedures. The aim of this study is to demonstrate the feasibility and utility of laparotomy with minimal incision based on the literature and exemplifying with a case. The case in question describes reconstruction of the intestinal transit with the use of this incision. Male, young, HIV-positive patient in a late postoperative of ileotiflectomy, terminal ileostomy and closing of the ascending colon by an acute perforating abdomen, due to ileocolonic tuberculosis. The barium enema showed a proximal stump of the right colon near the ileostomy. The access to the cavity was made through the orifice resulting from the release of the stoma, with a lateral-lateral ileo-colonic anastomosis with a 25 mm circular stapler and manual closure of the ileal stump. These surgeries require their own tactics, such as rigor in the lysis of adhesions, tissue traction, and hemostasis, in addition to requiring surgeon dexterity – but without the need for investments in technology; moreover, the learning curve is reported as being lower than that for videolaparoscopy. Laparotomy with minimal incision should be considered as a valid and viable option in the treatment of surgical conditions. Resumo: Procedimentos minimamente invasivos visam resolver a doença com o mínimo de trauma ao organismo, resultando em retorno rápido às atividades, reduções nas infecções, complicações, custos e na dor. A laparotomia com incisão mínima, algumas vezes referida como minilaparotomia, é um exemplo desses procedimentos minimamente invasivos. O objetivo deste trabalho é demonstrar a viabilidade e utilidade das laparotomias com incisão mínima com base na literatura e

  14. Efficacy and safety of 10,600-nm carbon dioxide fractional laser on facial skin with previous volume injections

    Directory of Open Access Journals (Sweden)

    Josiane Hélou

    2013-01-01

    Full Text Available Background: Fractionated carbon dioxide (CO 2 lasers are a new treatment modality for skin resurfacing. The cosmetic rejuvenation market abounds with various injectable devices (poly-L-lactic acid, polymethyl-methacrylate, collagens, hyaluronic acids, silicone. The objective of this study is to examine the efficacy and safety of 10,600-nm CO 2 fractional laser on facial skin with previous volume injections. Materials and Methods: This is a retrospective study including 14 patients treated with fractional CO 2 laser and who have had previous facial volume restoration. The indication for the laser therapy, the age of the patients, previous facial volume restoration, and side effects were all recorded from their medical files. Objective assessments were made through clinical physician global assessment records and improvement scores records. Patients′ satisfaction rates were also recorded. Results: Review of medical records of the 14 patients show that five patients had polylactic acid injection prior to the laser session. Eight patients had hyaluronic acid injection prior to the laser session. Two patients had fat injection, two had silicone injection and one patient had facial thread lift. Side effects included pain during the laser treatment, post-treatment scaling, post-treatment erythema, hyperpigmentation which spontaneously resolved within a month. Concerning the previous facial volume restoration, no granulomatous reactions were noted, no facial shape deformation and no asymmetry were encountered whatever the facial volume product was. Conclusion: CO 2 fractional laser treatments do not seem to affect facial skin which had previous facial volume restoration with polylactic acid for more than 6 years, hyaluronic acid for more than 0.5 year, silicone for more than 6 years, or fat for more than 1.4 year. Prospective larger studies focusing on many other variables (skin phototype, injected device type are required to achieve better

  15. Craniosynostosis incision: scalpel or cautery?

    Science.gov (United States)

    Wood, Jeyhan S; Kittinger, Benjamin J; Perry, Victor L; Adenola, Adeyemi; van Aalst, John A

    2014-07-01

    There is an ongoing debate regarding the optimal instrument for scalp incisions: the scalpel or electrocautery. The argument generally focuses on improved healing after an incision made with a knife and decreased bleeding when using electrocautery. This study compares the use of scalpel and electrocautery in making coronal incisions for patients undergoing surgical correction of craniosynostosis. The outcome metric used is wound healing within 6 months after surgery. All patients presenting to the University of North Carolina Children's Hospital with craniosynostosis between July 1, 2007 and January 1, 2010 requiring a coronal incision for surgical correction were prospectively enrolled. In all of these patients, half of the coronal incision was made with knife; the other half, with needle tip cautery. Side of the incision was specified at the time of surgery in the operative report. Patients were excluded from the study if the instrument for incision was not specified or if only 1 modality was used for the entire incision. Sixty-eight patients underwent cranial vault reconstruction, of which 58 met inclusion criteria. Of the 58 matched pairs, 55 were analyzed statistically. The 3 excluded cases were those who had midline complications. There were 17 wound complications (15%): 8 in the knife group, 6 in the cautery group, and 3 at midline (with indeterminate side for the problem). We found no statistically significant difference in wound healing between incisions made with a knife or with electrocautery.

  16. Optical design and analysis of carbon dioxide laser fusion systems using interferometry and fast Fourier transform techniques

    International Nuclear Information System (INIS)

    Viswanathan, V.K.

    1979-01-01

    The optical design and analysis of the LASL carbon dioxide laser fusion systems required the use of techniques that are quite different from the currently used method in conventional optical design problems. The necessity for this is explored and the method that has been successfully used at Los Alamos to understand these systems is discussed with examples. This method involves characterization of the various optical components in their mounts by a Zernike polynomial set and using fast Fourier transform techniques to propagate the beam, taking diffraction and other nonlinear effects that occur in these types of systems into account. The various programs used for analysis are briefly discussed

  17. The fourth incision: a cosmetic autopsy incision technique.

    Science.gov (United States)

    Patowary, Amarjyoti

    2010-03-01

    Autopsy procedure includes thorough external examination as well as internal examination including opening of all the body cavities for proper visualization of all the visceral organs. As such, there remains incision marks with stitches which harts the sentiment of the already traumatized relatives of the deceased. Moreover, it looks odd especially in cases of otherwise healthy dead bodies. So, autopsy incisions should be such that, we can get maximum possible visualization of the body cavities, particularly the thorax and abdomen, and at the same time the incision as well as the stitch marks are also hidden. This article is aimed to describe few modifications in the autopsy incisions for opening the thorax and abdomen and also proper visualization of the neck structures during autopsy where the incisions and the stitches are kept hidden.

  18. Effects of gamma irradiations on reactive pulsed laser deposited vanadium dioxide thin films

    Energy Technology Data Exchange (ETDEWEB)

    Madiba, I.G., E-mail: madibagiven@gmail.com [UNESCO-UNISA Africa Chair in Nanosciences/Nanotechnology, College of Graduate Studies, University of South Africa (UNISA), Muckleneuk Ridge, P O Box 392, Pretoria (South Africa); Empa, Swiss Federal Laboratories Materials Science and Technology, CH-8600 Dübendorf (Switzerland); Émond, N.; Chaker, M. [Institut National de la Recherche Scientifique (INRS),1650 Blvd. Lionel-Boulet, Varennes, Québec J3X1S2 (Canada); Thema, F.T. [UNESCO-UNISA Africa Chair in Nanosciences/Nanotechnology, College of Graduate Studies, University of South Africa (UNISA), Muckleneuk Ridge, P O Box 392, Pretoria (South Africa); iThemba LABS-National Research Foundation, 1 Old Faure Road, Somerset West 7129, PO Box 722, Somerset West, Western Cape Province (South Africa); Tadadjeu, S.I. [iThemba LABS-National Research Foundation, 1 Old Faure Road, Somerset West 7129, PO Box 722, Somerset West, Western Cape Province (South Africa); Department of Electrical, Electronics and Computer Engineering, French South African Institute of Technology/Cape Peninsula University of Technology, Bellville campus, PO Box 1906, Bellville, 7530 (South Africa); Muller, U.; Zolliker, P. [Empa, Swiss Federal Laboratories Materials Science and Technology, CH-8600 Dübendorf (Switzerland); Braun, A. [ETH Zurich, Swiss Federal Institute of Technology, CH-8057, Zurich (Switzerland); Empa, Swiss Federal Laboratories Materials Science and Technology, CH-8600 Dübendorf (Switzerland); Kotsedi, L. [iThemba LABS-National Research Foundation, 1 Old Faure Road, Somerset West 7129, PO Box 722, Somerset West, Western Cape Province (South Africa); and others

    2017-07-31

    Highlights: • Synthesis of VO{sub 2} thin films by Reactive pulsed laser deposition has been achieved. • Properties VO{sub 2} remain mainly unaffected when subjected to gamma ray doses similar to those encountered during space missions. • The long range crystal structure of VO{sub 2} remains intact upon irradiation on different doses up to 100 kGy. • XPS reveals a shift from V{sup 4+} to V{sup 5+} oxidation state upon irradiation, due to the frenkel pair formation on the surface. • Irradiated films show the characteristic SMT of VO{sub 2}, although the electrical and optical properties are slightly affected. - Abstract: Vanadium oxide films are considered suitable coatings for various applications such as thermal protective coating of small spacecrafts because of their thermochromic properties. While in outer space, such coating will be exposed to cosmic radiations which include γ-rays. To study the effect of these γ-rays on the coating properties, we have deposited vanadium dioxide (VO{sub 2}) films on silicon substrates and subjected them to extensive γ-irradiations with typical doses encountered in space missions. The prevalent crystallographic phase after irradiation remains the monoclinic VO{sub 2} phase but the films preferential orientation shifts to lower angles due to the presence of disordered regions caused by radiations. Raman spectroscopy measurements also evidences that the VO{sub 2} structure is slightly affected by gamma irradiation. Indeed, increasing the gamma rays dose locally alters the crystalline and electronic structures of the films by modifying the V–V inter-dimer distance, which in turns favours the presence of the VO{sub 2} metallic phase. From the XPS measurements of V2p and O1s core level spectra, an oxidation of vanadium from V{sup 4+} towards V{sup 5+} is revealed. The data also reveal a hydroxylation upon irradiation which is corroborated by the vanishing of a low oxidation state peak near the Fermi energy in the

  19. In vivo confocal laser microscopy of morphologic changes after small incision lenticule extraction with accelerated cross-linking (SMILE Xtra) in patients with thin corneas and high myopia.

    Science.gov (United States)

    Zhou, Yugui; Liu, Manli; Zhang, Ting; Zheng, Hua; Sun, Yuan; Yang, Xiaonan; Weng, Shengbei; Lin, Haiqin; Liu, Quan

    2018-01-01

    To evaluate the microstructural modifications and safety of small incision lenticule extraction combined with accelerated cross-linking (SMILE Xtra) in high myopia and thin corneas by means of in vivo confocal microscopy (IVCM) and 3D-OCT after a 6-month follow-up. Forty-three eyes with high myopia and thin corneas were enrolled. All eyes underwent SMILE procedure. After the lenticule was extracted, 0.25% riboflavin was injected into the interface and allowed to diffuse for 60 s. The eye was irradiated with UVA radiation of 30 mW/cm 2 for 90 s through the cap. The total energy delivered was 2.7 J/cm 2 . Morphologic modifications of corneal architecture were evaluated prior to SMILE Xtra and 7 days, 1, 3, and 6 months after SMILE by in vivo confocal microscopy (IVCM) and 3D-OCT. The corneal epithelial cells showed slight damage until 3 months postoperatively. The subepithelial nerve plexus decreased but no absence within the treatment zone at the first week after treatment, recolonized at 3 months postoperatively, and had mostly recovered at the 6 months postoperative but remained less than its normal baseline state. Keratocytes were absent in the surgical interface area, and the presence of strong reflective particles and cicatricial reaction in the anterior stroma were observed during the entire 6-month examination period. Increased hyperreflectivity was observed from the cap side at a depth of 60 µm to stroma bed at a depth of 388 µm through 6 months. The depth of the demarcation line in 40 eyes (93.0%) was at a mean depth of 296.12 ± 47.86 μm (range, 211-388 μm). No particular change between preoperative and postoperative corneal endothelium was observed. Confocal microscopy showed increased hyperreflectivity in the SMILE Xtra eyes, and no changes in corneal endothelium. We confirmed the safety of the SMILE Xtra but recognize that larger and longer-term studies of SMILE Xtra are necessary.

  20. [In-transit metastasis in melanoma: Efficacy of topical imiquimod combined with carbon dioxide laser or with electrocautery].

    Science.gov (United States)

    Elfatoiki, F-Z; Longvert, C; Clerici, T; Bourgault-Villada, I; Roudier-Pujol, C; Vasseur, E; Saiag, P

    2014-02-01

    In-transit metastases in cutaneous melanoma are common and difficult to manage. Therapy is mainly palliative. Use of topical imiquimod has been assessed for surface metastases. We report on four patients with cutaneous melanoma metastases treated with topical imiquimod associated with carbon dioxide laser in the first two patients and with electrocoagulation in the two others. For two patients, we noted complete regression of the lesions after 15 and 18 months. For the two others, treatment was stopped after 9 to 10 months because of progression of subcutaneous metastasis and distant metastasis. Topical imiquimod is an alternative treatment used in superficial in-transit metastasis of melanoma. Its use as a monotherapy is sometimes ineffective. We elected to use combined pre-treatment with carbon dioxide laser or electrocoagulation in order to potentiate the action of imiquimod. This simple and inexpensive therapeutic strategy constitutes a palliative treatment that can allow prolonged local control of cutaneous metastasis. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  1. Extensive tissue damage of bovine ovaries after bipolar ovarian drilling compared to monopolar electrocoagulation or carbon dioxide laser.

    Science.gov (United States)

    Hendriks, Marja-Liisa; van der Valk, Paul; Lambalk, Cornelis B; Broeckaert, Mark A M; Homburg, Roy; Hompes, Peter G A

    2010-02-01

    To evaluate the size of ovarian damage caused by ovarian drilling in polycystic ovary syndrome, the amount of inflicted damage was assessed for the most frequently used ovarian drilling techniques. Experimental prospective design. University clinic. Six fresh bovine ovaries per technique. Carbon dioxide (CO(2)) laser, monopolar electrocoagulation, and bipolar electrocoagulation were used for in vitro ovarian drilling. Amount of inflicted ovarian damage per procedure. Bipolar electrocoagulation resulted in significantly more destruction per burn than the CO(2) laser and monopolar electrocoagulation (287.6 versus 24.0 and 70.0 mm(3), respectively). The damage found per lesion was multiplied by the regularly applied number of punctures per procedure in daily practice (based on the literature). Again, the bipolar electrocoagulation resulted in significantly more tissue damage than the CO(2) laser and monopolar coagulation (2,876 versus 599 and 700 mm(3), respectively). Ovarian drilling, especially bipolar electrocoagulation, causes extensive destruction of the ovary. Given the same clinical effectiveness of the various procedures, it is essential to use the lowest possible dose that works; thus, the first choice should be CO(2) laser or monopolar electrocoagulation. Copyright 2010 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  2. Small-incision lenticule extraction (SMILE)

    DEFF Research Database (Denmark)

    Hansen, Rasmus Søgaard; Lyhne, Niels; Grauslund, Jakob

    2016-01-01

    surgery was 0.07 ± 0.03 (logMAR). However, 12 eyes (1.6 %) lost 2 or more lines of CDVA from before surgery to 3 months postoperatively. Simultaneous treatment of up to 3.00 D of astigmatism was not associated with less predictable refractive outcomes. CONCLUSIONS: In the short term, SMILE seemed......PURPOSE: To study the outcomes of small-incision lenticule extraction (SMILE) for treatment of myopia and myopic astigmatism. METHODS: Retrospective study of patients treated for myopia or myopic astigmatism with SMILE, using a VisuMax(®) femtosecond laser (Carl Zeiss Meditec, Jena, Germany...

  3. [Three Years Follow-up Study after Refractive Small Incision Lenticule Extraction (SMILE) Using 500 kHz Femtosecond Laser in "Fast Mode"].

    Science.gov (United States)

    Messerschmidt-Roth, A; Sekundo, W; Lazaridis, A; Schulze, S

    2017-01-01

    Background   The aim of this clinical trial was to check the results of laser built-in settings 3 years after ReLEx SMILE for moderate and high myopia in unselected "real life" patients. Patients and Methods   50 myopic eyes of 27 patients were called in for examination after 3 years. 25 of these eyes with a preoperative myopia under - 6D comprised the "moderate myopia subgroup". All surgeries were performed with the 500 kHz VisuMax® femtosecond laser (Carl Zeiss Meditec AG, Jena) in the "fast mode" setting. Results   The spherical equivalent (SE) of the entire group changed from - 6.18 D (± 1.91) prior to surgery to - 0.18 D (± 0.39) 3 years later. The preoperative SE in the moderate myopia subgroup changed from - 4.71 D (± 0.94) to - 0.04 D (± 0.23). 14 % of 50 eyes gained one line and 22 % lost one line of CDVA. The regression between month 3 and 36 was 0.07D for the entire group and 0.06 D for the moderate myopia subgroup. There were no late side effects. Primary undercorrection was predominantly seen in eyes over - 6 D. Conclusion   ReLEx SMILE shows remarkable stability over the entire range of myopias after 3 years, however primary undercorrection occurs predominantly in eyes of - 6.0 D, which necessitates nomogram adjustment. Georg Thieme Verlag KG Stuttgart · New York.

  4. Comparison of Carbon Dioxide Laser With Surgical Blade for Removal of Epulis Fissuratum. A Randomized Clinical Trial

    Science.gov (United States)

    Karimi, Abbas; Sobouti, Farhad; Torabi, Sara; Bakhshandehfard, Ali; Amirian, Armaghan; Shariati, Mahsa; Morshedi, Ehsan; Barati, Maryam

    2016-01-01

    Introduction: Epulis fissuratum is often formed as a result of a poor fitting denture. The conventional treatment for this fibrous hyperplastic tissue is to excise it using a scalpel and to close the wound by a continuous or an interrupted suture. The increased utilization of lasers in dentistry also includes the utilization of carbon dioxide (CO2) lasers in place of surgical scalpels in soft tissue surgeries. The objective of this study is to assess the feasibility of utilizing CO2 laser in place of scalpel in surgical treatment of epulis fissuratum. Methods: In this clinical trial research (IRCT code: IRCT2016071124969N2), 19 patients were selected with nearly symmetrical epulis fissuratums in the anterior part of the jaws. The hyperplastic tissue was evenly divided into two sections in each patient. One section was randomly selected and cut by CO2 laser and the other section by a surgical scalpel. The wound created by the scalpel was closed by appropriate number of interrupted sutures. Surgery duration and bleeding as well as vestibular depth, re-epithelialization and edema in both sections were noted and recorded after 7 and 14 days postoperatively. Results: The time of surgery and the amount of bleeding during surgery in the laser section was less and the vestibular depth was more than surgical scalpel section (P < 0.05). Surgical scalpel wound at day seventh healed significantly better than the section treated by the CO2 laser (P < 0.05). Wound in both sections healed similarly on day 14 and no statistical difference was observed. Edema presence was also equal in both sides after 7th and 14th following the surgery. Conclusion: According to the results it could be concluded that the use of CO2 laser may result in less surgery time, less bleeding during surgery, more vestibular depth, better re-epithelialization of the wound and less need for suturing. CO2 laser may be a clinically preferred method for surgical treatment of epulis fissuratum. PMID:28144443

  5. The efficacy of fractional carbon dioxide (CO2) laser combined with terbinafine hydrochloride 1% cream for the treatment of onychomycosis.

    Science.gov (United States)

    Shi, Jian; Li, Jin; Huang, He; Permatasari, Felicia; Liu, Juan; Xu, Yang; Wu, Di; Zhou, Bing-Rong; Luo, Dan

    2017-10-01

    Although systemic and topical antifungal agents are widely used to treat onychomycosis, oral medications can cause adverse effects and the efficacy of topical agents is not satisfying. Currently, laser treatment has been studied for its efficacy in the treatment of onychomycosis. Our study was aimed to evaluate the efficacy of fractional carbon dioxide (CO 2 ) laser treatment combined with terbinafine cream for 6 months in the treatment of onychomycosis and to analyze the influencing factors. A total of 30 participants (124 nails) with clinical and mycological diagnosis of onychomycosis received fractional CO 2 laser treatment at 2-week interval combined with terbinafine cream once daily for 6 months. The clinical efficacy rate (CER) was assessed from the percentage of fully normal-appearing nails or nails with ≤5% abnormal appearance, and the mycological clearance rate (MCR) was assessed from the percentage of nails with negative fungal microscopy. The CER was evaluated at 3 time points: at the end of treatment (58.9%), at 1 month after the last treatment (63.5%), and at 3 months after the last treatment (68.5%). The MCRs at 1 month and 3 months after the last treatment were 77.4 and 74.2%, respectively. The evaluation of influencing factors showed significantly higher CER (p terbinafine cream for 6 months was an effective and safe method for the treatment of onychomycosis. There were 5 factors that positively influenced the treatment outcome: age, clinical type of onychomycosis, nail thickness, involved nail, and species of fungus.

  6. Use of Zernike polynomials and interferometry in the optical design and assembly of large carbon-dioxide laser systems

    International Nuclear Information System (INIS)

    Viswanathan, V.K.

    1981-01-01

    This paper describes the need for non-raytracing schemes in the optical design and analysis of large carbon-dioxide lasers like the Gigawatt, Gemini, and Helios lasers currently operational at Los Alamos, and the Antares laser fusion system under construction. The scheme currently used at Los Alamos involves characterizing the various optical components with a Zernike polynomial set obtained by the digitization of experimentally produced interferograms of the components. A Fast Fourier Transform code then propagates the complex amplitude and phase of the beam through the whole system and computes the optical parameters of interest. The analysis scheme is illustrated through examples of the Gigawatt, Gemini, and Helios systems. A possible way of using the Zernike polynomials in optical design problems of this type is discussed. Comparisons between the computed values and experimentally obtained results are made and it is concluded that this appears to be a valid approach. As this is a review article, some previously published results are also used where relevant

  7. Use of a double-wave carbon dioxide laser for determining small concentrations of materials

    Energy Technology Data Exchange (ETDEWEB)

    Voitovich, A.P.; Dunaev, V.B.; Prokopov, A.P.

    1985-09-01

    According to this experiment, the smallest detectable concentration of trichloroethylene is C = 2.0/sup -5/ mg/cm/sup 2/. The experiments described were made with an unstabilized laser; it is expected that with an improved radiation recording and a laser with greater stability, the detection limit could be reduced by one or two orders of magnitude.

  8. Liquid in the major incision

    International Nuclear Information System (INIS)

    Herrera Jaramillo, Diego Alberto; Ortega Jaramillo, Hector

    2003-01-01

    We present the case of a patient with spill pleural extending in the left major incision. In the chest thorax PA, we could observe one of the complex radiographic appearances that take the reconfiguration of fluid in this localization, being this appearance dependent of the patient's position. Some points are also discussed on the anatomy of the major incisions and some of their radiographic characteristics

  9. Generalized eczematous reaction after fractional carbon dioxide laser therapy for tattoo allergy.

    Science.gov (United States)

    Meesters, Arne A; De Rie, Menno A; Wolkerstorfer, Albert

    2016-12-01

    Allergic tattoo reactions form a therapeutically difficult entity. Treatment with conventional quality-switched lasers does not completely remove the allergenic particles and may lead to generalized hypersensitivity reactions. Recently, ablative fractional laser therapy was introduced as a treatment for allergic tattoo removal. We present two cases of allergic reactions to red tattoo ink treated with 10,600-nm fractional CO 2 laser. At the end of treatment, almost complete removal of red ink accompanied by a significant reduction of symptoms was observed in the first patient, whereas the second patient developed an acute generalized eczematous reaction after five treatments. These findings confirm that ablative fractional laser therapy is capable of significant removal of tattoo ink in an allergic tattoo reaction. However, it implies a risk of generalized hypersensitivity reactions. To our knowledge, this is the first case of a generalized hypersensitivity reaction following treatment of tattoo allergy with the fractional CO 2 laser.

  10. Design of a high pulse repitition frequency carbon dioxide laser for processing high damage threshold materials

    Science.gov (United States)

    Chatwin, Christopher R.; McDonald, Donald W.; Scott, Brian F.

    1989-07-01

    The absence of an applications led design philosophy has compromised both the development of laser source technology and its effective implementation into manufacturing technology in particular. For example, CO2 lasers are still incapable of processing classes of refractory and non-ferrous metals. Whilst the scope of this paper is restricted to high power CO2 lasers; the design methodology reported herein is applicable to source technology in general, which when exploited, will effect an expansion of applications. The CO2 laser operational envelope should not only be expanded to incorporate high damage threshold materials but also offer a greater degree of controllability. By a combination of modelling and experimentation the requisite beam characteristics, at the workpiece, were determined then utilised to design the Laser Manufacturing System. The design of sub-system elements was achieved by a combination of experimentation and simulation which benefited from a comprehensive set of software tools. By linking these tools the physical processes in the laser - electron processes in the plasma, the history of photons in the resonator, etc. - can be related, in a detailed model, to the heating mechanisms in the workpiece.

  11. A Laser-Induced Fluorescence Instrument for Aircraft Measurements of Sulfur Dioxide in the Upper Troposphere and Lower Stratosphere

    Science.gov (United States)

    Rollins, Andrew W.; Thornberry, Troy D.; Ciciora, Steven J.; McLaughlin, Richard J.; Watts, Laurel A.; Hanisco, Thomas F.; Baumann, Esther; Giorgetta, Fabrizio R.; Bui, Thaopaul V.; Fahey, David W.

    2016-01-01

    This work describes the development and testing of a new instrument for in situ measurements of sulfur dioxide (SO2) on airborne platforms in the upper troposphere and lower stratosphere (UTLS). The instrument is based on the laser-induced fluorescence technique and uses the fifth harmonic of a tunable fiber-amplified semiconductor diode laser system at 1084.5 nm to excite SO2 at 216.9 nm. Sensitivity and background checks are achieved in flight by additions of SO2 calibration gas and zero air, respectively. Aircraft demonstration was performed during the NASA Volcano Plume Investigation Readiness and Gas-Phase and Aerosol Sulfur (VIRGAS) experiment, which was a series of flights using the NASA WB-57F during October 2015 based at Ellington Field and Harlingen, Texas. During these flights, the instrument successfully measured SO2 in the UTLS at background (non-volcanic) conditions with a precision of 2 ppt at 10 s and an overall uncertainty determined primarily by instrument drifts of +/- (16% + 0.9 ppt).

  12. Promising Option for Treatment of Striae Alba: Fractionated Microneedle Radiofrequency in Combination with Fractional Carbon Dioxide Laser

    Directory of Open Access Journals (Sweden)

    Farahnaz Fatemi Naeini

    2016-01-01

    Full Text Available Background. A consistent treatment has not been proposed for treatment of Striae Alba (SA. The present study was designed to compare the fractionated microneedle radiofrequency (FMR alone and in combination with fractional carbon dioxide laser (FMR + CO2 in the treatment of SA. Methods. Forty-eight pairs of SA from six patients were selected. Right or left SAs were randomly assigned to one of the treatment groups. The surface area of the SA before and after treatment and clinical improvement using a four-point scale were measured at the baseline, after one and three months. Results. The mean age of the patients was 30.17±5.19 years. The mean difference of the surface area between pre- and posttreatment in the FMR + CO2 group was significantly higher than that in the FMR group (p=0.003. Clinical improvement scales showed significantly higher improvement in the FMR + CO2 group than in the FMR group in the first and second follow-up (p=0.002 and 0.004, resp.. There were no major persistence side-effects in both groups. Conclusions. The results showed that FMR + CO2 laser was more effective than FMR alone in the treatment of SA.

  13. Single incision pediatric endoscopic surgery: advantages of relatively large incision

    International Nuclear Information System (INIS)

    Yilmaz, E.; Afsarlar, E.; Karaman, I.

    2015-01-01

    To describe Single Incision Pediatric Endoscopic Surgery (SIPES) performed on children with various diagnoses, emphasizing its advantages. Study Design: An observational case series. Place and Duration of Study: Department of Pediatric Surgery, Dr. Sami Ulus Maternity and Child Health Hospital, Ankara, Turkey, from January 2011 to November 2014. Methodology: A review of patient charts was conducted in which SIPES was preferred as the surgical procedure. Patient demographics, operative details, operative time, clinical outcomes, postoperative pain and cosmesis were analyzed. Results: SIPES was performed on 45 patients (21 girls, 24 boys). Thirty-three appendectomies, 5 varicocelectomies, 3 oophorectomies, 2 ovarian and one paratubal cyst excision, and one fallopian tube excision were performed. All except one procedures were performed through our standard 2cm umbilical vertical or smile incision. In 18 cases, abdominal irrigation/aspiration was easily performed through the existing larger incision, as is done with open surgical technique. None of the patients had early postoperative shoulder/back pain since complete disinflation of CO/sub 2/ could be ensured. All of the patients/parents were satisfied with the cosmesis. Conclusion: SIPES has the advantages of limiting the surgical scar to within the umbilicus and providing easy disinflation of CO/sub 2/, allowing intraabdominal cleaning and extraction of large volume tissue samples through a single large umbilical incision. (author)

  14. Endoscopic treatment of pharyngeal pouches: electrocoagulation vs carbon dioxide (CO2) laser

    NARCIS (Netherlands)

    Flikweert, D. C.; van der Baan, S.

    1992-01-01

    Endoscopic treatment of a hypopharyngeal diverticulum was performed in 75 patients during the period 1976-1990. Initially electrocoagulation was used to divide the septum between the diverticulum and oesophagus. More recently, the CO2 laser combined with the operating microscope has been used.

  15. Fast imaging of laser induced plasma emission of vanadium dioxide (VO2) target

    CSIR Research Space (South Africa)

    Masina, BN

    2013-10-01

    Full Text Available The main objective of this study is to fully optimise the synthesis of vanadium oxide nanostructures using pulsed laser deposition. We will attempt to realise this by studying the mechanism of the plasma formation and expansion during the pulsed...

  16. In vivo study of necrosis on the liver tissue of Wistar rats: a combination of photodynamic therapy and carbon dioxide laser ablation

    International Nuclear Information System (INIS)

    Rego, R F; Nicolodelli, G; Bagnato, V S; Araujo, M T; Tirapelli, L F; Araujo-Moreira, F M

    2013-01-01

    Photodynamic therapy (PDT) is known to be limited to applications in large volume tumors due to its limited penetration. Therefore, a combination of PDT and carbon dioxide (CO 2 ) laser ablation may constitute a potential protocol to destroy bulk tumors because it involves an association of these two techniques allowing the removal of visible lesions with a high selectivity of destruction of remnant tumors. The main aim of this study is to investigate the most appropriate procedure to combine use of a CO 2 laser and PDT on livers of healthy rats, and to analyze different techniques of this treatment using three types of photosensitizers (PSs). Forty eight animals were separated to form six groups: (1) only CO 2 laser ablation, (2) drug and CO 2 laser ablation, (3) only PDT, (4) drug and light (PDT) followed by CO 2 laser ablation, (5) ablated with CO 2 laser followed by PDT, and (6) drug followed by CO 2 laser ablation and light. For each group, three types of photosensitization were used: topical 5-aminolevulinic acid (ALA), intravenous ALA and intravenous Photogem ® . Thirty hours after the treatments, the animals were sacrificed and the livers removed. The depth of necrosis was analyzed and measured, considering microscopic and macroscopic aspects. The results show that the effects of the PDT were considerably enhanced when combined with CO 2 laser ablation, especially when the PDT was performed before the CO 2 laser ablation. (paper)

  17. Estudo comparativo histológico na prega vocal após incisão com instrumental a frio e com laser de CO2 em modelo animal Comparative histology study of the vocal folds after incision with cold instruments and CO2 laser in an animal model

    Directory of Open Access Journals (Sweden)

    Fernando C. C. Santos

    2003-12-01

    Jako and Strong's works in 1972(1,2, when CO2 was first applied in the treatment of papilomatosis and early glottic malign lesions, its indications have risen, most especially in benign lesions, due to new technology developed over the last years as, for example, the reduction of microspot and the super-pulse, reducing the thermal effects on the tissues. METHODS: In this work, incisions with cold steel instruments and 1watt continuous mode and super-pulse CO2 laser were conducted on canine vocal folds. The amount of collagen deposited over the vocal folds was observed through histological exams using the Sirius Red method. RESULTS: The amount of collagen on the vocal folds was greater than the control group and statistically greater in the group of animals submitted to surgical procedures using cold instruments than procedures involving CO2. There was no statistical difference between the control group and the group submitted to incisions with cold steel instruments. CONCLUSIONS: The larynx surgery with CO2 laser, when employed in low potency, with small microspot and super-pulse, is a safe method in relation to the collagen deposit when compared with cold blade instruments.

  18. Kinetics of laser pulse vaporization of uranium dioxide by mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, C.

    1981-11-01

    Safety analyses of nuclear reactors require knowledge of the evaporation behavior of UO/sub 2/ at temperatures well above the melting point of 3140 K. In this study, rapid transient heating of a small spot on a UO/sub 2/ specimen was accomplished by a laser pulse, which generates a surface temperature excursion. This in turn vaporizes the target surface and the gas expands into vacuum. The surface temperature transient was monitored by a fast-response automatic optical pyrometer. The maximum surface temperatures investigated range from approx. 3700 K to approx. 4300 K. A computer program was developed to simulate the laser heating process and calculate the surface temperature evolution. The effect of the uncertainties of the high temperature material properties on the calculation was included in a sensitivity study for UO/sub 2/ vaporization. The measured surface temperatures were in satisfactory agreements.

  19. Superficial parotidectomy via facelift incision

    NARCIS (Netherlands)

    Lohuis, Peter J. F. M.; Tan, M. Liane; Bonte, Katrien; van den Brekel, Michiel W. M.; Balm, Alfons J. M.; Vermeersch, Hubert B.

    2009-01-01

    The stigma of a visually prominent facial scar following parotid surgery can be distressing to a young patient. The surgical technique of parotidectomy via a facelift incision is described and evaluated. Thirty patients with a benign lesion of the parotid gland underwent a partial superficial

  20. Modeling of carbon monoxide oxidation kinetics over NASA carbon dioxide laser catalysts

    Science.gov (United States)

    Herz, Richard K.

    1989-01-01

    The recombination of CO and O2 formed by the dissociation of CO2 in a sealed CO2 laser discharge zone is examined. Conventional base-metal-oxide catalysts and conventional noble-metal catalysts are not effective in recombining the low O2/CO ratio at the low temperatures used by the lasers. The use of Pt/SnO2 as the noble-metal reducible-oxide (NMRO), or other related materials from Group VIIIA and IB and SnO2 interact synergistically to produce a catalytic activity that is substantially higher than either componet separately. The Pt/SnO2 and Pd/SnO2 were reported to have significant reaction rates at temperatures as low as -27 C, conditions under which conventional catalysts are inactive. The gas temperature range of lasers is 0 + or - 40 C. There are three general ways in which the NMRO composite materials can interact synergistically: one component altering the properties of another component; the two components each providing independent catalytic functions in a complex reaction mechanism; and the formation of catalytic sites through the combination of two components at the atomic level. All three of these interactions may be important in low temperature CO oxidation over NMRO catalysts. The effect of the noble metal on the oxide is discussed first, followed by the effect of the oxide on the noble metal, the interaction of the noble metal and oxide to form catalytic sites, and the possible ways in which the CO oxidation reaction is catalyzed by the NMRO materials.

  1. Fast- and ultra-fast laser pulse induced reactions between carbon dioxide and methane

    CSIR Research Space (South Africa)

    Kotze, FJ

    2010-03-01

    Full Text Available at 2060 cm?1 is reported to be due to the stretch mode of other organic CO bonds that may have 200 F. Jaco Kotze et al./ Journal of Natural Gas Chemistry Vol. 19 No. 2 2010 formed [13]. Results show that CO2 has been excited by the nanosecond laser...] Zewail A H. J Phys Chem A, 2000, 104: 5660 [13] http://webbook.nist.gov/chemistry:NIST Standard Reference Database Number 69. Accessed November 2008 [14] Silverstein R M, Webster F X, Kiemle D J. Spectrometric iden- tification of organic compounds...

  2. Development and Preliminary Tests of an Open-Path Airborne Diode Laser Absorption Instrument for Carbon Dioxide

    Science.gov (United States)

    Diskin, Glenn S.; DiGangi, Joshua P.; Yang, Melissa; Slate, Thomas A.; Rana, Mario

    2015-01-01

    Carbon dioxide (CO2) is well known for its importance as an atmospheric greenhouse gas, with many sources and sinks around the globe. Understanding the fluxes of carbon into and out of the atmosphere is a complex and daunting challenge. One tool applied by scientists to measure the vertical flux of CO2 near the surface uses the eddy covariance technique, most often from towers but also from aircraft flying specific patterns over the study area. In this technique, variations of constituents of interest are correlated with fluctuations in the local vertical wind velocity. Measurement requirements are stringent, particularly with regard to precision, sensitivity to small changes, and temporal sampling rate. In addition, many aircraft have limited payload capability, so instrument size, weight, and power consumption are also important considerations. We report on the development and preliminary application of an airborne sensor for the measurement of atmospheric CO2. The instrument, modeled on the successful DLH (Diode Laser Hygrometer) series of instruments, has been tested in the laboratory and on the NASA DC-8 aircraft. Performance parameters such as accuracy, precision, sensitivity, specificity, and temporal response are discussed in the context of typical atmospheric variability and suitability for flux measurement applications. On-aircraft, in-flight data have been obtained and are discussed as well. Performance of the instrument has been promising, and continued flight testing is planned during 2016.

  3. A histopathologic evaluation of the Plasma Skin Regeneration System (PSR) versus a standard carbon dioxide resurfacing laser in an animal model.

    Science.gov (United States)

    Fitzpatrick, R; Bernstein, E; Iyer, S; Brown, D; Andrews, P; Penny, K

    2008-02-01

    A variety of high energy, pulsed, and scanned carbon dioxide lasers are available to perform cutaneous resurfacing. Rhytec has developed a device for skin regeneration that utilizes energy delivered via a burst of nitrogen plasma. This study was undertaken to benchmark the energy outputs of the plasma skin regeneration device as compared to an ultra-short pulsed carbon dioxide laser (the control device). The two systems were compared for time to complete healing, and the healing response post-treatment. Three Yucatan mini-pigs were utilized for this study. Following anesthesia, five experimental sites were marked along the skin atop the psoas muscle on each side of the spine. Treatment was applied using either the plasma skin regeneration system or the carbon dioxide laser, with one site remaining untreated as a control. Biopsies were taken from all treatment sites 0, 2, 7, 14, 30, and 60 days following treatment and processed to hematoxylin-eosin staining. Histopathologic examination was performed by observers blinded as to the treatment conditions. Skin treated with the plasma skin regeneration device showed a wider range of tissue effects across the energy settings used as compared to the laser treatment. All treatment sites had clinically regenerated epidermis by 7 days after treatment, with active cellular response below the D/E junction noted at the day 30 time-point at energies ranging from 2 to 4 J. The Rhytec PSR system provides an attractive alternative to standard CO2 laser with good remodeling of tissue architecture. Epidermis regenerated after PSR treatment shows a smoother surface profile than adjacent untreated tissue.

  4. Comparison of Efficacy of Carbon Dioxide (CO2) Laser with Cutting Diathermy in Surgical Excision of Early Carcinoma Tongue.

    Science.gov (United States)

    Rashid, Muhammad; Hashmi, Muhammad Ali; Maqbool, Shahzad; Dastigir, Majid

    2015-10-01

    To compare the efficacy of carbon dioxide (CO(2)) laser with cutting diathermy as a cutting device in surgical excision of early carcinoma tongue. Experimental study. Combined Military Hospital (CMH), Rawalpindi and CMH, Lahore, from July 2008 to July 2011. Twenty two biopsy proven cases of T(1) and early T(2) squamous cell carcinoma of tongue were divided in two equal groups of 11 each labeled as A and B. Tumor was excised by CO(2) laser in group A while cutting diathermy was done in group B. For both groups tumor excision time, per-operative blood loss, postoperative oral swelling and pain was recorded. Excision time of tumor was assessed in minutes and amount of blood loss in milliliters till complete hemostasis after removal of primary tumor. Postoperatively patients were assessed on 12 hourly basis for 48 hours for pain. Pain was analyzed on visual analogue score 1 - 10. Oral swelling was assessed once after 24 hours and labeled as mild, moderate and severe. Independent sample t-test was applied for analysis of excision time, postoperative pain and per-operative blood loss for both groups. Postoperative swelling was analyzed using Fisher's exact test. P-value of < 0.05 was considered significant. The mean age at diagnosis in group A was 49.36 ± 5.27 years, while in group B patients had mean age of 50.73 ± 8.13 years. In group A, 4/11 (36.3%) patients were having tumor stage T(1) while 7/11 (63.6%) had T(2) stage tumor. In group B, 5/11 (45.4%) were having T1 and 6/11 (54.5%) were having stage T(2) tumor. Excision time was significantly shorter for group B (p=0.003), but group A had less postoperative pain (p=0.001), less per-operative blood loss (p=0.001) and less postoperative oral swelling (p=0.021). Early carcinoma tongue is better removed by laser than electrocautery in terms of postoperative morbidity, per-operative blood loss, postoperative pain and oral swelling.

  5. Effects of gamma irradiations on reactive pulsed laser deposited vanadium dioxide thin films

    Science.gov (United States)

    Madiba, I. G.; Émond, N.; Chaker, M.; Thema, F. T.; Tadadjeu, S. I.; Muller, U.; Zolliker, P.; Braun, A.; Kotsedi, L.; Maaza, M.

    2017-07-01

    Vanadium oxide films are considered suitable coatings for various applications such as thermal protective coating of small spacecrafts because of their thermochromic properties. While in outer space, such coating will be exposed to cosmic radiations which include γ-rays. To study the effect of these γ-rays on the coating properties, we have deposited vanadium dioxide (VO2) films on silicon substrates and subjected them to extensive γ-irradiations with typical doses encountered in space missions. The prevalent crystallographic phase after irradiation remains the monoclinic VO2 phase but the films preferential orientation shifts to lower angles due to the presence of disordered regions caused by radiations. Raman spectroscopy measurements also evidences that the VO2 structure is slightly affected by gamma irradiation. Indeed, increasing the gamma rays dose locally alters the crystalline and electronic structures of the films by modifying the V-V inter-dimer distance, which in turns favours the presence of the VO2 metallic phase. From the XPS measurements of V2p and O1s core level spectra, an oxidation of vanadium from V4+ towards V5+ is revealed. The data also reveal a hydroxylation upon irradiation which is corroborated by the vanishing of a low oxidation state peak near the Fermi energy in the valence band. Our observations suggest that gamma radiations induce the formation of Frenkel pairs. Moreover, THz transmission measurements show that the long range structure of VO2 remains intact after irradiation whilst the electrical measurements evidence that the coating resistivity decreases with gamma irradiation and that their transition temperature is slightly reduced for high gamma ray doses. Even though gamma rays are only one of the sources of radiations that are encountered in space environment, these results are very promising with regards to the potential of integration of such VO2 films as a protective coating for spacecrafts.

  6. Synthesis and characterization of titanium dioxide thin films deposited by laser ablation

    International Nuclear Information System (INIS)

    Escobar A, L.; Camps C, E.; Falcon B, T.; Carapia M, L.; Haro P, E.; Camacho L, M.A.

    2000-01-01

    In this work are presented the results obtained when TiO 2 thin films were deposited using the laser ablation technique. Thin films were deposited at different substrate temperatures, and different oxygen pressures, with the purpose of studying the influence of this deposit parameters in the structural characteristics of the films obtained. The structural characterization was realized through Raman Spectroscopy and X-ray Diffraction (XRD), the surface morphology of the layers deposited was verified by Scanning Electron Microscopy (Sem). The results show that the films obtained are of TiO 2 in rutile phase, getting this at low substrate temperatures, its morphology shows a soft surface with some spattered particles and good adherence. (Author)

  7. Optical, compositional and structural properties of pulsed laser deposited nitrogen-doped Titanium-dioxide

    Science.gov (United States)

    Farkas, B.; Heszler, P.; Budai, J.; Oszkó, A.; Ottosson, M.; Geretovszky, Zs.

    2018-03-01

    N-doped TiO2 thin films were prepared using pulsed laser deposition by ablating metallic Ti target with pulses of 248 nm wavelength, at 330 °C substrate temperature in reactive atmospheres of N2/O2 gas mixtures. These films were characterized by spectroscopic ellipsometry, X-ray photoelectron spectroscopy and X-ray diffraction. Optical properties are presented as a function of the N2 content in the processing gas mixture and correlated to nitrogen incorporation into the deposited layers. The optical band gap values decreased with increasing N concentration in the films, while a monotonically increasing tendency and a maximum can be observed in case of extinction coefficient and refractive index, respectively. It is also shown that the amount of substitutional N can be increased up to 7.7 at.%, but the higher dopant concentration inhibits the crystallization of the samples.

  8. Experiment and modeling: Ignition of aluminum particles with a carbon dioxide laser

    Science.gov (United States)

    Mohan, Salil

    Aluminum is a promising ingredient for high energy density compositions used in propulsion systems, explosives, and pyrotechnics. Aluminum powder fuel additives enable one to achieve higher combustion enthalpies and reaction temperatures. Therefore, to develop aluminum based novel and customized high density energetic materials, understanding of ignition and combustion kinetics of aluminum powders is required. In most practical systems, metal ignition and combustion occur in environments with rapidly changing temperatures and gas compositions. The kinetics of exothermic reactions in related energetic materials is commonly characterized by thermal analysis, where the heating rates are very low, on the order of 1--50 K/min. The extrapolation of the identified kinetics to the high heating rates is difficult and requires direct experimental verification. This difficulty led to development of new experimental approaches to directly characterize ignition kinetics for the heating rates in the range of 103--104 K/s. However, the practically interesting heating rates of 106 K/s range have not been achieved. This work is directed at development of an experimental technique and respective heat transfer model for studying ignition of aluminum and other micron-sized metallic particles at heating rates varied around 106 K/s. The experimental setup uses a focused CO2 laser as a heating source and a plate capacitor aerosolizer to feed the aluminum particles into the laser beam. The setup allows using different environment for particle aerosolization. The velocities of particles in the jet are in the range of 0.1 --0 3 m/s. For each selected jet velocity, the laser power is increased until the particles are observed to ignite. The ignition is detected optically using a digital camera and a photomultiplier. The ignition thresholds for spherical aluminum powder were measured at three different particle jet velocities, in air environment. A single particle heat transfer model was

  9. Postoperative Granulomas at Liposuction Incision Sites.

    Science.gov (United States)

    Weniger, Frederick G; White, Peter F; Barrero Castedo, Carlos E

    2016-02-01

    Since most liposuction incisions heal uneventfully, difficult healing in such incisions must be investigated. In the cases of two gynecomastia liposuction patients in which a water-based lubricating gel was used on the liposuction incisions, the incisions failed to heal. For both patients, workup uncovered palisading granulomas at the lateral inframammary fold incision sites several months after otherwise successful surgeries. These two cases are presented and the previous literature is reviewed, with consideration given to the etiology and prevention of such granulomas. LEVEL OF EVIDENCE 5: Risk. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  10. Fractional carbon dioxide laser versus low-dose UVA-1 phototherapy for treatment of localized scleroderma: a clinical and immunohistochemical randomized controlled study.

    Science.gov (United States)

    Shalaby, S M; Bosseila, M; Fawzy, M M; Abdel Halim, D M; Sayed, S S; Allam, R S H M

    2016-11-01

    Morphea is a rare fibrosing skin disorder that occurs as a result of abnormal homogenized collagen synthesis. Fractional ablative laser resurfacing has been used effectively in scar treatment via abnormal collagen degradation and induction of healthy collagen synthesis. Therefore, fractional ablative laser can provide an effective modality in treatment of morphea. The study aimed at evaluating the efficacy of fractional carbon dioxide laser as a new modality for the treatment of localized scleroderma and to compare its results with the well-established method of UVA-1 phototherapy. Seventeen patients with plaque and linear morphea were included in this parallel intra-individual comparative randomized controlled clinical trial. Each with two comparable morphea lesions that were randomly assigned to either 30 sessions of low-dose (30 J/cm 2 ) UVA-1 phototherapy (340-400 nm) or 3 sessions of fractional CO 2 laser (10,600 nm-power 25 W). The response to therapy was then evaluated clinically and histopathologically via validated scoring systems. Immunohistochemical analysis of TGF-ß1 and MMP1 was done. Patient satisfaction was also assessed. Wilcoxon signed rank test for paired (matched) samples and Spearman rank correlation equation were used as indicated. Comparing the two groups, there was an obvious improvement with fractional CO 2 laser that was superior to that of low-dose UVA-1 phototherapy. Statistically, there was a significant difference in the clinical scores (p = 0.001), collagen homogenization scores (p = 0.012), and patient satisfaction scores (p = 0.001). In conclusion, fractional carbon dioxide laser is a promising treatment modality for cases of localized morphea, with proved efficacy of this treatment on clinical and histopathological levels.

  11. THERAPEUTIC OF SKIN AGING WITH CARBON DIOXIDE LASER SKIN RESURFACING AND COMBINATION WITH AIR COOLING

    Directory of Open Access Journals (Sweden)

    NKA Maya Damayanti

    2013-12-01

    Full Text Available Normal 0 false false false EN-US X-NONE X-NONE MicrosoftInternetExplorer4 So far, a lot of people who want their face skin always looks young though age continued to grow. It cannot be denied that aging will occur in everyone although some faster or later occur. Various ways were developed by scientists to fix this issue. Laser Skin Resurfacing (LSR technique to tighten facial skin is a procedure that is popular among the public and the practice of medicine. CO2 LSR technique is still a gold standard was used. Pain during surgery can be reduced when this technique was combined with air cooling. In addition, the adverse effects of post-operative might be tolerated.   /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0in 5.4pt 0in 5.4pt; mso-para-margin:0in; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:"Times New Roman"; mso-bidi-theme-font:minor-bidi;}

  12. Efficacy and safety of fractional carbon dioxide laser for treatment of unwanted facial freckles in phototypes II-IV: a pilot study.

    Science.gov (United States)

    El Zawahry, Bakr; Zaki, Naglaa; Hafez, Vanessa; Abdel Hay, Rania; Hay, Rania Abdel; Fahim, Aya

    2014-11-01

    Facial freckles are a cosmetic concern to Egyptians, particularly young females. Several therapeutic lines exist with variable response rates and limitations. Fractional carbon dioxide (FCO2) laser provides minimal ablation and therefore less down time and less side effects. The efficacy and safety of this laser technology have still not been studied in freckles. The aim of this study is to assess the efficacy and safety of FCO2 laser in the treatment of unwanted facial freckles in Egyptians. Twenty patients undergone a single session of FCO2 laser and then were followed up clinically a month later. Photographs were taken before treatment and at follow-up visit and were assessed by three blinded investigators. Percent of global improvement was measured on a 4-point grading scale. Patient's satisfaction and adverse events were recorded. Two patients (10 %) showed grade 1 improvement, while eight patients (40 %) showed grade 2 improvement. Nine patients (45 %) showed grade 3 improvement, and only one patient (5 %) showed grade 4 improvement. FCO2 laser resurfacing is effective and safe in treatment of facial freckles in skin phototypes II-IV. It can offer a more practical alternative to topical treatments, and a cheaper alternative to Q-switched lasers.

  13. Efficacy of Punch Elevation Combined with Fractional Carbon Dioxide Laser Resurfacing in Facial Atrophic Acne Scarring: A Randomized Split-face Clinical Study

    Science.gov (United States)

    Faghihi, Gita; Nouraei, Saeid; Asilian, Ali; Keyvan, Shima; Abtahi-Naeini, Bahareh; Rakhshanpour, Mehrdad; Nilforoushzadeh, Mohammad Ali; Hosseini, Sayed Mohsen

    2015-01-01

    Background: A number of treatments for reducing the appearance of acne scars are available, but general guidelines for optimizing acne scar treatment do not exist. The aim of this study was to compare the clinical effectiveness and side effects of fractional carbon dioxide (CO2) laser resurfacing combined with punch elevation with fractional CO2 laser resurfacing alone in the treatment of atrophic acne scars. Materials and Methods: Forty-two Iranian subjects (age range 18–55) with Fitzpatrick skin types III to IV and moderate to severe atrophic acne scars on both cheeks received randomized split-face treatments: One side received fractional CO2 laser treatment and the other received one session of punch elevation combined with two sessions of laser fractional CO2 laser treatment, separated by an interval of 1 month. Two dermatologists independently evaluated improvement in acne scars 4 and 16 weeks after the last treatment. Side effects were also recorded after each treatment. Results: The mean ± SD age of patients was 23.4 ± 2.6 years. Clinical improvement of facial acne scarring was assessed by two dermatologists blinded to treatment conditions. No significant difference in evaluation was observed 1 month after treatment (P = 0.56). Their evaluation found that fractional CO2 laser treatment combined with punch elevation had greater efficacy than that with fractional CO2 laser treatment alone, assessed 4 months after treatment (P = 0.02). Among all side effects, coagulated crust formation and pruritus at day 3 after fractional CO2 laser treatment was significant on both treatment sides (P < 0.05). Conclusion: Concurrent use of fractional laser skin resurfacing with punch elevation offers a safe and effective approach for the treatment of acne scarring. PMID:26538695

  14. Efficacy of punch elevation combined with fractional carbon dioxide laser resurfacing in facial atrophic acne scarring: A randomized split-face clinical study

    Directory of Open Access Journals (Sweden)

    Gita Faghihi

    2015-01-01

    Full Text Available Background: A number of treatments for reducing the appearance of acne scars are available, but general guidelines for optimizing acne scar treatment do not exist. The aim of this study was to compare the clinical effectiveness and side effects of fractional carbon dioxide (CO 2 laser resurfacing combined with punch elevation with fractional CO 2 laser resurfacing alone in the treatment of atrophic acne scars. Materials and Methods: Forty-two Iranian subjects (age range 18-55 with Fitzpatrick skin types III to IV and moderate to severe atrophic acne scars on both cheeks received randomized split-face treatments: One side received fractional CO 2 laser treatment and the other received one session of punch elevation combined with two sessions of laser fractional CO 2 laser treatment, separated by an interval of 1 month. Two dermatologists independently evaluated improvement in acne scars 4 and 16 weeks after the last treatment. Side effects were also recorded after each treatment. Results: The mean ± SD age of patients was 23.4 ± 2.6 years. Clinical improvement of facial acne scarring was assessed by two dermatologists blinded to treatment conditions. No significant difference in evaluation was observed 1 month after treatment (P = 0.56. Their evaluation found that fractional CO 2 laser treatment combined with punch elevation had greater efficacy than that with fractional CO 2 laser treatment alone, assessed 4 months after treatment (P = 0.02. Among all side effects, coagulated crust formation and pruritus at day 3 after fractional CO 2 laser treatment was significant on both treatment sides (P < 0.05. Conclusion: Concurrent use of fractional laser skin resurfacing with punch elevation offers a safe and effective approach for the treatment of acne scarring.

  15. In vivo effect of carbon dioxide laser-skin resurfacing and mechanical abrasion on the skin's microbial flora in an animal model.

    Science.gov (United States)

    Manolis, Evangelos N; Tsakris, Athanassios; Kaklamanos, Ioannis; Markogiannakis, Antonios; Siomos, Konstadinos

    2006-03-01

    Although beam-scanning carbon dioxide (CO2) lasers have provided a highly efficient tool for esthetic skin rejuvenation there has been no comprehensive animal studies looking into microbial skin changes following CO2 laser skin resurfacing. To evaluate the in vivo effects of CO2 laser skin resurfacing in an experimental rat model in comparison with mechanical abrasion on the skin microbial flora. Four separate cutaneous sections of the right dorsal surface of 10 Wistar rats were treated with a CO2 laser, operating at 18 W and delivering a radiant energy of 5.76 J/cm2, while mechanical abrasions of the skin were created on four sections of the left dorsal surface using a scalpel. Samples for culture and biopsies were obtained from the skin surfaces of the rats on day 1 of application of the CO2 laser or mechanical abrasion, as well as 10, 30, and 90 days after the procedure. The presence of four microorganisms (staphylococci, streptococci, diphtheroids, and yeasts) was evaluated as a microbe index for the skin flora, and colony counts were obtained using standard microbiological methods. Skin biopsy specimens, following CO2 laser treatment, initially showed epidermal and papillary dermal necrosis and later a re-epithelization of the epidermis as well as the generation of new collagen on the upper papillary dermis. The reduction in microbial counts on day 1 of the CO2 laser-inflicted wound was statistically significant for staphylococci and diphtheroids compared with the baseline counts (p=.004 and pSkin resurfacing using CO2 lasers considerably reduces microbial counts of most microorganisms in comparison with either normal skin flora or a scalpel-inflicted wound. This might contribute to the positive clinical outcome of laser skin resurfacing.

  16. Modified tubularized incised plate urethroplasty

    Directory of Open Access Journals (Sweden)

    Shivaji Mane

    2013-01-01

    Full Text Available Aim: To share our experience of doing tubularized incised plate urethroplasty with modifications. Materials and Methods: This is a single surgeon personal series from 2004 to 2009. One hundred patients of distal hypospadias were subjected for Snodgrass urethroplasty with preputioplasty. The age range was 1 to 5 year with mean age of 2.7 years. Selection criteria were good urethral plate, without chordee and torsion needing complete degloving. Main technical modification from original Snodgrass procedure was spongioplasty, preputioplasty, and dorsal slit when inability to retract prepuce during surgery. Results: Average follow-up period is 23 months. Seven (7% patients developed fistula and one patient had complete preputial dehiscence. Phimosis developed in three (3% patients and required circumcision. Dorsal slit was required in seven patients. One patient developed meatal stenosis in postoperative period. All other patients are passing single urinary stream and have cosmesis that is acceptable. Conclusions: Modified tubularized incised plate urethroplasty with preputioplasty effectively gives cosmetically normal looking penis with low complications.

  17. A Comparison between the Effects of Glucantime, Topical Trichloroacetic Acid 50% plus Glucantime, and Fractional Carbon Dioxide Laser plus Glucantime on Cutaneous Leishmaniasis Lesions

    Directory of Open Access Journals (Sweden)

    Fariba Jaffary

    2016-01-01

    Full Text Available Background. Cutaneous leishmaniasis is an endemic disease in Iran. Pentavalent antimonial drugs have been the first line of therapy in cutaneous leishmaniasis for many years. However, the cure rate of these agents is still not favorable. This study was carried out to compare the efficacies of intralesional glucantime with topical trichloroacetic acid 50% (TCA 50% + glucantime and fractional carbon dioxide laser + glucantime in the treatment of cutaneous leishmaniasis. Methods. A total of 90 patients were randomly divided into three groups of 30 to be treated with intralesional injection of glucantime, a combination of topical TCA 50% and glucantime, or a combination of fractional laser and glucantime. The overall clinical improvement and changes in sizes of lesions and scars were assessed and compared among three groups. Results. The mean duration of treatment was 6.1±2.1 weeks in all patients (range: 2–12 weeks and 6.8±1.7, 5.2±1.0, and 6.3±3.0 weeks in glucantime, topical TCA plus glucantime, and fractional laser plus glucantime groups, respectively (P=0.011. Complete improvement was observed in 10 (38.5%, 27 (90%, and 20 (87% patients of glucantime, glucantime + TCA, and glucantime + laser groups, respectively (P<0.001. Conclusion. Compared to glucantime alone, the combination of intralesional glucantime and TCA 50% or fractional CO2 laser had significantly higher and faster cure rate in patients with cutaneous leishmaniasis.

  18. Modified incision for maxillectomy: our experience.

    Science.gov (United States)

    Bhavana, Kranti; Tyagi, Isha; Ramani, Mukesh Kumar

    2012-06-01

    Radical maxillectomy has usually been done by the classical Weber Ferguson incision since age old times and still is being used widely due to its advantage of excellent exposure and minimal scarring as the incision follows the natural skin crease. In our modification of radical maxillectomy incision we avoid a scar on the midface by performing a midface degloving and combining it with a subconjunctival eye incision thus avoiding any cosmetic deformity and associated eye complication. It also avoids the late complication of cutaneous fistula following radiotherapy to these areas and due to early healing of the wound, early radiotherapy can be started.

  19. A 4 U laser heterodyne radiometer for methane (CH4) and carbon dioxide (CO2) measurements from an occultation-viewing CubeSat

    Science.gov (United States)

    Wilson, Emily L.; DiGregorio, A. J.; Riot, Vincent J.; Ammons, Mark S.; Bruner, William W.; Carter, Darrell; Mao, Jianping; Ramanathan, Anand; Strahan, Susan E.; Oman, Luke D.; Hoffman, Christine; Garner, Richard M.

    2017-03-01

    We present a design for a 4 U (20 cm  ×  20 cm  ×  10 cm) occultation-viewing laser heterodyne radiometer (LHR) that measures methane (CH4), carbon dioxide (CO2) and water vapor (H2O) in the limb that is designed for deployment on a 6 U CubeSat. The LHR design collects sunlight that has undergone absorption by the trace gas and mixes it with a distributive feedback (DFB) laser centered at 1640 nm that scans across CO2, CH4, and H2O absorption features. Upper troposphere/lower stratosphere measurements of these gases provide key inputs to stratospheric circulation models: measuring stratospheric circulation and its variability is essential for projecting how climate change will affect stratospheric ozone.

  20. A 4 U Laser Heterodyne Radiometer for Methane (CH4) and Carbon Dioxide (CO2) Measurements from an Occultation-Viewing CubSat

    Science.gov (United States)

    Wilson, Emily L.; DiGregorio, A. J.; Riot, Vincent J.; Ammons, Mark S.; Bruner, WIlliam W.; Carter, Darrell; Mao, Jianping; Ramanathan, Anand; Strahan, Susan E.; Oman, Luke D.; hide

    2017-01-01

    We present a design for a 4 U (20 cm 20 cm 10 cm) occultation-viewing laser heterodyne radiometer (LHR) that measures methane (CH4), carbon dioxide (CO2) and water vapor(H2O) in the limb that is designed for deployment on a 6 U CubeSat. The LHR design collects sunlight that has undergone absorption by the trace gas and mixes it with a distributive feedback (DFB) laser centered at 1640 nm that scans across CO2, CH4, and H2O absorption features. Upper troposphere lower stratosphere measurements of these gases provide key inputs to stratospheric circulation models: measuring stratospheric circulation and its variability is essential for projecting how climate change will affect stratospheric ozone.

  1. A 4 U laser heterodyne radiometer for methane (CH4) and carbon dioxide (CO2) measurements from an occultation-viewing CubeSat

    International Nuclear Information System (INIS)

    Wilson, Emily L; Oman, Luke D; DiGregorio, A J; Garner, Richard M; Riot, Vincent J; Ammons, Mark S; Bruner, William W; Carter, Darrell; Mao, Jianping; Ramanathan, Anand; Strahan, Susan E; Hoffman, Christine

    2017-01-01

    We present a design for a 4 U (20 cm  ×  20 cm  ×  10 cm) occultation-viewing laser heterodyne radiometer (LHR) that measures methane (CH 4 ), carbon dioxide (CO 2 ) and water vapor (H 2 O) in the limb that is designed for deployment on a 6 U CubeSat. The LHR design collects sunlight that has undergone absorption by the trace gas and mixes it with a distributive feedback (DFB) laser centered at 1640 nm that scans across CO 2 , CH 4 , and H 2 O absorption features. Upper troposphere/lower stratosphere measurements of these gases provide key inputs to stratospheric circulation models: measuring stratospheric circulation and its variability is essential for projecting how climate change will affect stratospheric ozone. (paper)

  2. Studies on the mechanism of printing film-coated tablets containing titanium dioxide in the film by using UV laser irradiation.

    Science.gov (United States)

    Kato, Yoshiteru; Nakashima, Yasuhiko; Shino, Naoki; Sasaki, Koichi; Hosokawa, Akihiro; Ishihara, Hiroshi

    2010-04-01

    The purpose of this article is to study a detailed mechanism of printing when film-coated tablets were irradiated by UV laser at a wavelength of 355 nm. Hydroxypropylmethylcellulose (HPMC) film containing titanium dioxide (TiO(2)) and the film not containing TiO(2) and TiO(2) powder were lirradiated by the UV laser and estimated by the morphological observation by zoom stereo microscope, thermogravimetric analysis (TGA), total color difference (dE), X-ray powder diffraction (XRD), and dispersive Raman microscopy. In the case of the film containing TiO(2), the film showed a visible change in its color from white to gray by the UV laser irradiation. By zoom stereo microscope, it was found that the entire UV laser-irradiated area was not grayed uniformly, but many black particles, whose diameter was about 2 microm, were observed on the film. When TiO(2) powder was irradiated by the UV laser, a visible change in its color from white to gray was observed similar to the case of the film containing TiO(2). There were many black particles locally in the UV laser-treated TiO(2) powder by the morphological observation, and these black particles, agglomerates of the grayed oxygen-defected TiO(2), were associated with the visible change of the TiO(2). It was found that the film-coated tablets were printed utilizing the formation of the black particles by the agglomeration of the grayed oxygen-defected TiO(2) by the UV laser irradiation.

  3. A low-cost, portable, laser heterodyne radiometer for validating passive satellite observations of column carbon dioxide and methane

    Science.gov (United States)

    Wilson, E. L.; DiGregorio, A.; Villanueva, G. L.; Miletti, K.; Grunberg, C.; Grunberg, M.; Floyd, M.; Menendez, A. R.

    2017-12-01

    We present a low-cost, portable, miniaturized, laser heterodyne radiometer (mini-LHR) capable of measuring column carbon dioxide (CO2) and methane (CH4) in remote locations to validate passive satellite observations. A benefit of the portability is that mini-LHR instruments can be calibrated and compared site-by-side to quantify any internal biases, or any biases in stationary column instruments such as those in the total carbon column observing network (TCCON). This is the latest iteration of an instrument that has been under development by our team since 2009. During our recent Interdisciplinary Science (IDS) effort that involved measuring carbon emissions over thawing permafrost, it became clear that our mini-LHR needed to be redesigned to be significantly smaller, lighter, and to operate from a small solar panel so that it could be easily carried to the field sites located within the Bonanza Creek Research Forest near Fairbanks, AK. The boreal peatland sites at Bonanza Creek have forests that are underlain by cold soils, permafrost, collapse scar thermokarst bogs resulting from permafrost thaw, and rich fens with various underlying sediments and gravels that are not frozen. While these sites are extremely interesting for their role in carbon storage, the practical issue with these sites is that they are very wet (the fen site for example is periodically under several inches of water) and the trails to reach these sites are extremely muddy, narrow, and populated with swarms of biting insects. The soils at these sites are delicate and easily damaged by excessive foot traffic. They are also prone to periodic wild fires - making permanent column instrument installations impractical. Here, we compare data from the permafrost field work as well as data collected as part of the Hawai'i Space Exploration Analog and Simulation (Hi-SEAS) project where crewmembers are currently testing the mini-LHR on an isolated Mars-like site on the Mauna Loa side of the saddle area on

  4. A new non-vital tooth bleaching method using titanium dioxide and 3.5% hydrogen peroxide with a 405-nm diode laser or a halogen lamp

    International Nuclear Information System (INIS)

    Suemori, T; Kato, J; Nakazawa, T; Akashi, G; Hirai, Y

    2008-01-01

    To establish a safer and more effective bleaching method for discolored pulpless teeth, we examined bleaching from the pulpal dentin side using a 3.5% hydrogen peroxide solution containing titanium dioxide. The twenty bovine blood-stained discolored enamel-dentin plates of 1.0 mm enamel thickness and 2.0 mm dentin thickness were used. The bleaching agent was applied to the dentin side that was then irradiated with a 405-nm diode laser (800 mW/cm 2 ) or a halogen lamp (720 mW/cm 2 ) for 15 minutes. The bleaching effect was assessed by spectrophotometric measurement of the color of the specimens from the dentin and enamel side for every 5 minutes, and then dentin or enamel surface was examined with a scanning electron microscope. The 3.5% hydrogen peroxide solution containing titanium dioxide proved to have a strong bleaching effect. The color difference after laser irradiation was higher than that after halogen lamp irradiation, however, there was no significant difference between them. No changes in the enamel surface morphology were found and open dentinal tubules with no smear layer were clearly observed at the pulpal dentin surface in both groups

  5. Facile synthesis of silicon carbide-titanium dioxide semiconducting nanocomposite using pulsed laser ablation technique and its performance in photovoltaic dye sensitized solar cell and photocatalytic water purification

    Energy Technology Data Exchange (ETDEWEB)

    Gondal, M.A., E-mail: magondal@kfupm.edu.sa [Laser Research Group, Physics Department & Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Ilyas, A.M. [Laser Research Group, Physics Department & Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Baig, Umair [Laser Research Group, Physics Department & Center of Excellence in Nanotechnology, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Center of Excellence for Scientific Research Collaboration with MIT, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2016-08-15

    Highlights: • SiC–TiO{sub 2} semiconducting nanocomposites synthesized by nanosecond PLAL technique. • Synthesized nanocomposites were morphologically and optically characterized. • Nanocomposites were applied for the photocatalytic degradation of toxic organic dye. • Photovoltaic performance was investigated in dye sensitized solar cell. - Abstract: Separation of photo-generated charge carriers (electron and holes) is a major approach to improve the photovoltaic and photocatalytic performance of metal oxide semiconductors. For harsh environment like high temperature applications, ceramic like silicon carbide is very prominent. In this work, 10%, 20% and 40% by weight of pre-oxidized silicon carbide was coupled with titanium dioxide (TiO{sub 2}) to form nanocomposite semiconductor via elegant pulsed laser ablation in liquid technique using second harmonic 532 nm wavelength of neodymium-doped yttrium aluminium garnet (Nd-YAG) laser. In addition, the effect of silicon carbide concentration on the performance of silicon carbide-titanium dioxide nanocomposite as photo-anode in dye sensitized solar cell and as photocatalyst in photodegradation of methyl orange dye in water was also studied. The result obtained shows that photo-conversion efficiency of the dye sensitized solar cell was improved from 0.6% to 1.65% and the percentage of methyl orange dye removed was enhanced from 22% to 77% at 24 min under ultraviolet–visible solar spectrum in the nanocomposite with 10% weight of silicon carbide. This remarkable performance enhancement could be due to the improvement in electron transfer phenomenon by the presence of silicon carbide on titanium dioxide.

  6. Efficacy of autologous platelet-rich plasma combined with fractional ablative carbon dioxide resurfacing laser in treatment of facial atrophic acne scars: A split-face randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Gita Faghihi

    2016-01-01

    Full Text Available Background: Autologous platelet-rich plasma has recently attracted significant attention throughout the medical field for its wound-healing ability. Aims: This study was conducted to investigate the potential of platelet-rich plasma combined with fractional laser therapy in the treatment of acne scarring. Methods: Sixteen patients (12 women and 4 men who underwent split-face therapy were analyzed in this study. They received ablative fractional carbon dioxide laser combined with intradermal platelet-rich plasma treatment on one half of their face and ablative fractional carbon dioxide laser with intradermal normal saline on the other half. The injections were administered immediately after laser therapy. The treatment sessions were repeated after an interval of one month. The clinical response was assessed based on patient satisfaction and the objective evaluation of serial photographs by two blinded dermatologists at baseline, 1 month after the first treatment session and 4 months after the second. The adverse effects including erythema and edema were scored by participants on days 0, 2, 4, 6, 8, 15 and 30 after each session. Results: Overall clinical improvement of acne scars was higher on the platelet-rich plasma-fractional carbon dioxide laser treated side but the difference was not statistically significant either 1 month after the first treatment session (P = 0.15 or 4 months after the second (P = 0.23. In addition, adverse effects (erythema and edema on the platelet-rich plasma-fractional carbon dioxide laser-treated side were more severe and of longer duration. Limitations: Small sample size, absence of all skin phototypes within the study group and lack of objective methods for the evaluation of response to treatment and adverse effects were the limitations. Conclusion: This study demonstrated that adding platelet-rich plasma to fractional carbon dioxide laser treatment did not produce any statistically significant synergistic effects

  7. Efficacy of autologous platelet-rich plasma combined with fractional ablative carbon dioxide resurfacing laser in treatment of facial atrophic acne scars: A split-face randomized clinical trial.

    Science.gov (United States)

    Faghihi, Gita; Keyvan, Shima; Asilian, Ali; Nouraei, Saeid; Behfar, Shadi; Nilforoushzadeh, Mohamad Ali

    2016-01-01

    Autologous platelet-rich plasma has recently attracted significant attention throughout the medical field for its wound-healing ability. This study was conducted to investigate the potential of platelet-rich plasma combined with fractional laser therapy in the treatment of acne scarring. Sixteen patients (12 women and 4 men) who underwent split-face therapy were analyzed in this study. They received ablative fractional carbon dioxide laser combined with intradermal platelet-rich plasma treatment on one half of their face and ablative fractional carbon dioxide laser with intradermal normal saline on the other half. The injections were administered immediately after laser therapy. The treatment sessions were repeated after an interval of one month. The clinical response was assessed based on patient satisfaction and the objective evaluation of serial photographs by two blinded dermatologists at baseline, 1 month after the first treatment session and 4 months after the second. The adverse effects including erythema and edema were scored by participants on days 0, 2, 4, 6, 8, 15 and 30 after each session. Overall clinical improvement of acne scars was higher on the platelet-rich plasma-fractional carbon dioxide laser treated side but the difference was not statistically significant either 1 month after the first treatment session (P = 0.15) or 4 months after the second (P = 0.23). In addition, adverse effects (erythema and edema) on the platelet-rich plasma-fractional carbon dioxide laser-treated side were more severe and of longer duration. Small sample size, absence of all skin phototypes within the study group and lack of objective methods for the evaluation of response to treatment and adverse effects were the limitations. This study demonstrated that adding platelet-rich plasma to fractional carbon dioxide laser treatment did not produce any statistically significant synergistic effects and also resulted in more severe side effects and longer downtime.

  8. Efficacy of autologous platelet-rich plasma combined with fractional ablative carbon dioxide resurfacing laser in treatment of facial atrophic acne scars: A split-face randomized clinical trial

    OpenAIRE

    Gita Faghihi; Shima Keyvan; Ali Asilian; Saeid Nouraei; Shadi Behfar; Mohamad Ali Nilforoushzadeh

    2016-01-01

    Background: Autologous platelet-rich plasma has recently attracted significant attention throughout the medical field for its wound-healing ability. Aims: This study was conducted to investigate the potential of platelet-rich plasma combined with fractional laser therapy in the treatment of acne scarring. Methods: Sixteen patients (12 women and 4 men) who underwent split-face therapy were analyzed in this study. They received ablative fractional carbon dioxide laser combined with intradermal ...

  9. Fractional carbon dioxide laser for the treatment of facial atrophic acne scars: prospective clinical trial with short and long-term evaluation.

    Science.gov (United States)

    Elcin, Gonca; Yalici-Armagan, Basak

    2017-12-01

    The aim of this study was to evaluate the efficacy and safety of fractional carbon dioxide laser for the treatment of acne scars. Thirty-one participants, 15 female and 16 male, whose mean age was 34.84 ± 10.94 years, were included in this prospective study. The study took place between 2012 and 2016. Participants were evaluated with the "ECCA Grading Scale" before the first session, 3 months (short-term evaluation) and 3 years after the last session (long-term evaluation). Participants received two or three treatment sessions at 4-week intervals, with a 10,600 nm fractional carbon dioxide laser with pulse energies ranging between 100 and 160 mJ, 120 spot type, 75-100 spot/cm 2 density, and 30 W power. Self-assessments by the participants were done 3 months and 3 years after the last session. The mean ECCA score was 107.90 ± 39.38 before the first session, and 82.17 ± 36.23 at the time of short-term evaluation (p = 0.000). The grade of improvement at the short-term evaluation was as follows: no improvement, mild, moderate, and significant improvement for 7 (22.6%), 11 (35.5%), 9 (29%), and 4 (12.9%) of the participants, respectively. Regarding self-assessments, 80.6 and 61.3% of the participants rated themselves as having at least mild improvement at the short-term and the long-term follow-up periods, respectively. The results of this study suggest that fractional carbon dioxide laser is an efficient treatment option for acne scars. Furthermore, self-assessment results show that more than half of the participants still experience at least mild improvement at the end of 3 years.

  10. Flexible omnidirectional carbon dioxide laser as an effective tool for resection of brainstem, supratentorial, and intramedullary cavernous malformations.

    Science.gov (United States)

    Choudhri, Omar; Karamchandani, Jason; Gooderham, Peter; Steinberg, Gary K

    2014-03-01

    Lasers have a long history in neurosurgery, yet bulky designs and difficult ergonomics limit their use. With its ease of manipulation and multiple applications, the OmniGuide CO2 laser has reintroduced laser technology to the microsurgical resection of brain and spine lesions. This laser, delivered through a hollow-core fiber lined with a unidirectional mirror, minimizes energy loss and allows precise targeting. To analyze resections performed by the senior author from April 2009 to March 2013 of 58 cavernous malformations (CMs) in the brain and spine with the use of the OmniGuide CO2 laser, to reflect on lessons learned from laser use in eloquent areas, and to share data on comparisons of laser power calibration and histopathology. Data were collected from electronic medical records, radiology reports, operative room records, OmniGuide CO2 laser case logs, and pathology records. Of 58 CMs, approximately 50% were in the brainstem (30) and the rest were in supratentorial (26) and intramedullary spinal locations (2). Fifty-seven, ranging from 5 to 45 mm, were resected, with a subtotal resection in 1. Laser power ranged from 2 to 10 W. Pathology specimens showed minimal thermal damage compared with traditionally resected specimens with bipolar coagulation. The OmniGuide CO2 laser is safe and has excellent precision for the resection of supratentorial, brainstem, and spinal intramedullary CMs. No laser-associated complications occurred, and very low energy was used to dissect malformations from their surrounding hemosiderin-stained parenchymas. The authors recommend its use for deep-seated and critically located CMs, along with traditional tools.

  11. Incision extension is the optimal method of difficult gallbladder extraction at laparoscopic cholecystectomy.

    Science.gov (United States)

    Bordelon, B M; Hobday, K A; Hunter, J G

    1992-01-01

    An unsolved problem of laparoscopic cholecystectomy is the optimal method of removing the gallbladder with thick walls and a large stone burden. Proposed solutions include fascial dilatation, stone crushing, and ultrasonic, high-speed rotary, or laser lithotripsy. Our observation was that extension of the fascial incision to remove the impacted gallbladder was time efficient and did not increase postoperative pain. We reviewed the narcotic requirements of 107 consecutive patients undergoing laparoscopic cholecystectomy. Fifty-two patients required extension of the umbilical incision, and 55 patients did not have their fascial incision enlarged. Parenteral meperidine use was 39.5 +/- 63.6 mg in the patients requiring fascial incision extension and 66.3 +/- 79.2 mg in those not requiring fascial incision extension (mean +/- standard deviation). Oral narcotic requirements were 1.1 +/- 1.5 doses vs 1.3 +/- 1.7 doses in patients with and without incision extension, respectively. The wide range of narcotic use in both groups makes these apparent differences not statistically significant. We conclude that protracted attempts at stone crushing or expensive stone fragmentation devices are unnecessary for the extraction of a difficult gallbladder during laparoscopic cholecystectomy.

  12. Single Incision Laparoscopic Splenectomy: Our First Experiences

    Directory of Open Access Journals (Sweden)

    Umut Barbaros

    2011-06-01

    Full Text Available Objective: Most laparoscopic surgeons have attempted to reduce incisional morbidity and improve cosmetic outcomes by using less and smaller trocars. Single incision laparoscopic splenectomy is a new laparoscopic procedure. Herein we would like to present our experiences.Material and Methods: Between January 2009 and June 2009, data of the 7 patients who underwent single incision laparoscopic splenectomy were evaluated retrospectively.Results: There were 7 patients (5 females and 2 males with a mean age of 29.9 years. The most common splenectomy indication was idiopathic thrombocytopenic purpura. Single incision laparoscopic splenectomy was performed successfully in 6 patients. In one patient the operation was converted to an open procedure.Conclusion: With surgeons experienced in minimally invasive surgery, single incision laparoscopic splenectomy could be performed successfully. However, in order to demonstrate the differneces between standard laparoscopic splenectomy and SILS splenetomy, prospective randomized comparative studies are required.

  13. Single-incision total laparoscopic hysterectomy

    Directory of Open Access Journals (Sweden)

    Sinha Rakesh

    2011-01-01

    Full Text Available Single-incision laparoscopic surgery is an alternative to conventional multiport laparoscopy. Single-access laparoscopy using a transumbilical port affords maximum cosmetic benefits because the surgical incision is hidden in the umbilicus. The advantages of single-access laparoscopic surgery may include less bleeding, infection, and hernia formation and better cosmetic outcome and less pain. The disadvantages and limitations include longer surgery time, difficulty in learning the technique, and the need for specialized instruments. Ongoing refinement of the surgical technique and instrumentation is likely to expand its role in gynecologic surgery in the future. We perform single-incision total laparoscopic hysterectomy using three ports in the single transumbilical incision.

  14. Detection of gain enhancement in laser-induced fluorescence of rhodamine B lasing dye by silicon dioxide nanostructures-coated cavity

    Science.gov (United States)

    Al-Tameemi, Mohammed N. A.

    2018-03-01

    In this work, nanostructured silicon dioxide films are deposited by closed-field unbalanced direct-current (DC) reactive magnetron sputtering technique on two sides of quartz cells containing rhodamine B dye dissolved in ethanol with 10‒5 M concentration as a random gain medium. The preparation conditions are optimized to prepare highly pure SiO2 nanostructures with a minimum particle size of about 20 nm. The effect of SiO2 films as external cavity for the random gain medium is determined by the laser-induced fluorescence of this medium, and an increase of about 200% in intensity is observed after the deposition of nanostructured SiO2 thin films on two sides of the dye cell.

  15. Mast Quadrant-assisted Minimally Invasive Modified Transforaminal Lumbar Interbody Fusion: Single Incision Versus Double Incision

    Directory of Open Access Journals (Sweden)

    Xin-Lei Xia

    2015-01-01

    Full Text Available Background: The concept of minimally invasive techniques is to make every effort to reduce tissue damage. Certainly, reducing skin incision is an important part of these techniques. This study aimed to investigate the clinical feasibility of Mast Quadrant-assisted modified transforaminal lumbar interbody fusion (TLIF with a small single posterior median incision. Methods: During the period of March 2011 to March 2012, 34 patients with single-segment degenerative lumbar disease underwent the minimally invasive modified TLIF assisted by Mast Quadrant with a small single posterior median incision (single incision group. The cases in this group were compared to 37 patients with single-segment degenerative lumbar disease in the double incision group. The perioperative conditions of patients in these two groups were statistically analyzed and compared. The Oswestry Disability Index (ODI scores, Visual Analog Scale (VAS scores, and sacrospinalis muscle damage evaluation indicators before operation and 3, 12 months postoperation were compared. Results: A total of 31 and 35 cases in the single incision and double incision groups, respectively, completed at least 12 months of systemic follow-up. The differences in perioperative conditions between the two groups were not statistically significant. The incision length of the single incision group was significantly shorter than that of the double incision group (P < 0.01. The ODI and VAS scores of patients in both groups improved significantly at 3 and 12 months postoperation. However, these two indicators at 3 and 12 months postoperation and the sacrospinalis muscle damage evaluation indicators at 3 months postoperation did not differ significantly between the two groups (P ≥ 0.05. Conclusions: Mast Quadrant-assisted modified TLIF with a small single posterior median incision has excellent clinical feasibility compared to minimally invasive TLIF with a double paramedian incision.

  16. Measurement of atmospheric carbon dioxide and water vapor in built-up urban areas in the Gandhinagar-Ahmedabad region in India using a portable tunable diode laser spectroscopy system.

    Science.gov (United States)

    Roy, Anirban; Sharma, Neetesh Kumar; Chakraborty, Arup Lal; Upadhyay, Abhishek

    2017-11-01

    This paper reports open-path in situ measurements of atmospheric carbon dioxide at Gandhinagar (23.2156°N, 72.6369°E) and Ahmedabad (23.0225°N, 72.5714°E) in the heavily industrialized state of Gujarat in western India. Calibration-free second harmonic wavelength modulation spectroscopy (2f WMS) is used to carry out accurate and fully automated measurements. The mean values of the mole fraction of carbon dioxide at four locations were 438 ppm, 495 ppm, 550 ppm, and 740 ppm, respectively. These values are much higher than the current global average of 406.67 ppm. A 1 mW, 2004-nm vertical cavity surface-emitting laser is used to selectively interrogate the R16 transition of carbon dioxide at 2003.5 nm (4991.2585 cm -1 ). The 2f WMS signal corresponding to the gas absorption line shape is simulated using spectroscopic parameters available in the HITRAN database and relevant laser parameters that are extracted in situ from non-absorbing spectral wings of the harmonic signals. The mole fraction of carbon dioxide is extracted in real-time by a MATLAB program from least-squares fit of the simulated 2f WMS signal to the corresponding experimentally obtained signal. A 10-mW, 1392.54-nm distributed feedback laser is used at two of the locations to carry out water vapor measurements using direct absorption spectroscopy. This is the first instance of a portable tunable diode laser spectroscopy system being deployed in an urban location in India to measure atmospheric carbon dioxide and water vapor under varying traffic conditions. The measurements clearly demonstrate the need to adopt tunable diode laser spectroscopy for precise long-term monitoring of greenhouse gases in the Indian subcontinent.

  17. DNA Methylation Modulates Nociceptive Sensitization after Incision.

    Directory of Open Access Journals (Sweden)

    Yuan Sun

    Full Text Available DNA methylation is a key epigenetic mechanism controlling DNA accessibility and gene expression. Blockade of DNA methylation can significantly affect pain behaviors implicated in neuropathic and inflammatory pain. However, the role of DNA methylation with regard to postoperative pain has not yet been explored. In this study we sought to investigate the role of DNA methylation in modulating incisional pain and identify possible targets under DNA methylation and contributing to incisional pain. DNA methyltranferase (DNMT inhibitor 5-Aza-2'-deoxycytidine significantly reduced incision-induced mechanical allodynia and thermal sensitivity. Aza-2'-deoxycytidine also reduced hindpaw swelling after incision, suggesting an anti-inflammatory effect. Global DNA methylation and DNMT3b expression were increased in skin after incision, but none of DNMT1, DNMT3a or DNMT3b was altered in spinal cord or DRG. The expression of proopiomelanocortin Pomc encoding β-endorphin and Oprm1 encoding the mu-opioid receptor were upregulated peripherally after incision; moreover, Oprm1 expression was further increased under DNMT inhibitor treatment. Finally, local peripheral injection of the opioid receptor antagonist naloxone significantly exacerbated incision-induced mechanical hypersensitivity. These results suggest that DNA methylation is functionally relevant to incisional nociceptive sensitization, and that mu-opioid receptor signaling might be one methylation regulated pathway controlling sensitization after incision.

  18. Single scrotal incision orchiopexy - a systematic review

    Directory of Open Access Journals (Sweden)

    Hugo Fabiano Fernandes Novaes

    2013-06-01

    Full Text Available Objective To conduct a systematic review on single scrotal incision orchiopexy. Materials and Methods A search was performed using Pubmed, through which 16 articles were selected out of a total of 133. The following conditions were considered exclusion criteria: other surgical methods such as an inguinal procedure or a laparoscopic approach, retractile testes, or patients with previous testicular or inguinal surgery. Results A total of 1558 orchiopexy surgeries initiated with a transcrotal incision were analyzed. Patients' ages ranged between 5 months and 21 years. Thirteen studies used high scrotal incisions, and low scrotal incisions were performed in the remainder of the studies. In 55 cases (3.53%, there was a need for inguinal incision. Recurrence was observed in 9 cases, testicular atrophy in 3, testicular hypotrophy in 2, and surgical site infections in 13 cases. High efficacy rates were observed, varying between 88% and 100%. Conclusions Single scrotal incision orchiopexy proved to be an effective technique and is associated with low rates of complications.

  19. Laser fusion: an overview

    International Nuclear Information System (INIS)

    Boyer, K.

    1975-01-01

    The laser fusion concept is described along with developments in neodymium and carbon dioxide lasers. Fuel design and fabrication are reviewed. Some spin-offs of the laser fusion program are discussed. (U.S.)

  20. Transconjunctival incision for total maxillectomy--an alternative for subciliary incision.

    Science.gov (United States)

    Goyal, Amit; Tyagi, Isha; Jain, Shilpa; Syal, Rajan; Singh, Alok Pratap; Kapila, Rajeev

    2011-09-01

    A subciliary incision may be associated with various complications of the lower eyelid when it is used during a total maxillectomy. The use of the transconjunctival incision instead is an alternative in suitable patients. The records of 17 patients were reviewed in whom a transconjunctival incision was used during total maxillectomy. These included 13 in whom the Weber-Ferguson incision was used, and 4 who had a sublabial incision. There was mild conjunctival oedema in all the cases during the immediate postoperative period but it did not last for more than two days. Four patients had mild to moderate oedema of the lid that resolved within two days. One had mild ectropion with transient epiphora, which was caused by early removal of the medial canthal sutures. We found the approach to be cosmetically acceptable as it avoids a scar in the subciliary region. The transconjunctival incision can be used in place of the subciliary incision for lateral exposure during total maxillectomy. There are few complications associated with the lower lid, and it has good cosmetic results; if it is combined with a sublabial incision in suitable patients, the maxillectomy is virtually scar-free. Copyright © 2010 British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Comparison of surgically induced astigmatism in various incisions in manual small incision cataract surgery.

    Science.gov (United States)

    Jauhari, Nidhi; Chopra, Deepak; Chaurasia, Rajan Kumar; Agarwal, Ashutosh

    2014-01-01

    To determine the surgically induced astigmatism (SIA) in Straight, Frown and Inverted V shape (Chevron) incisions in manual small incision cataract surgery (SICS). A prospective cross sectional study was done on a total of 75 patients aged 40y and above with senile cataract. The patients were randomly divided into three groups (25 each). Each group received a particular type of incision (Straight, Frown or Inverted V shape incisions). Manual SICS with intraocular lens (IOL) implantation was performed. The patients were compared 4wk post operatively for uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA) and SIA. All calculations were performed using the SIA calculator version 2.1, a free software program. The study was analyzed using SPSS version 15.0 statistical analysis software. The study found that 89.5% of patients in Straight incision group, 94.2% in Frown incision group and 95.7% in Inverted V group attained BCVA post-operatively in the range of 6/6 to 6/18. Mean SIA was minimum (-0.88±0.61D×90 degrees) with Inverted V incision which was statistically significant. Inverted V (Chevron) incision gives minimal SIA.

  2. Single incision laparoscopic colorectal resection: Our experience

    Directory of Open Access Journals (Sweden)

    Chinnusamy Palanivelu

    2012-01-01

    Full Text Available Background: A prospective case series of single incision multiport laparoscopic colorectal resections for malignancy using conventional laparoscopic trocars and instruments is described. Materials and Methods: Eleven patients (seven men and four women with colonic or rectal pathology underwent single incision multiport laparoscopic colectomy/rectal resection from July till December 2010. Four trocars were placed in a single transumblical incision. The bowel was mobilized laparoscopically and vessels controlled intracorporeally with either intra or extracorporeal anastomosis. Results: Three patients had carcinoma in the caecum, one in the hepatic flexure, two in the rectosigmoid, one in the descending colon, two in the rectum and two had ulcerative pancolitis (one with high grade dysplasia and another with carcinoma rectum. There was no conversion to standard multiport laparoscopy or open surgery. The median age was 52 years (range 24-78 years. The average operating time was 130 min (range 90-210 min. The average incision length was 3.2 cm (2.5-4.0 cm. There were no postoperative complications. The average length of stay was 4.5 days (range 3-8 days. Histopathology showed adequate proximal and distal resection margins with an average lymph node yield of 25 nodes (range 16-30 nodes. Conclusion: Single incision multiport laparoscopic colorectal surgery for malignancy is feasible without extra cost or specialized ports/instrumentation. It does not compromise the oncological radicality of resection. Short-term results are encouraging. Long-term results are awaited.

  3. Primary closure of equine laryngotomy incisions

    DEFF Research Database (Denmark)

    Lindegaard, C.; Karlsson, L.; Ekstrøm, Claus Thorn

    2016-01-01

    incision between January 1995 and June 2012 were reviewed. Horses with a laryngotomy incision closed in three layers for primary healing were included. Descriptive data on healing characteristics and complications of laryngotomy wounds were collected from the medical records and via follow......The objective was to report healing characteristics and complications after primary closure of equine laryngotomies and analyse factors potentially associated with complications. This retrospective case series of the medical records of horses (n = 180) undergoing laryngoplasty and laryngotomy...... after primary closure of equine laryngotomy incisions are infrequent and considered of minimal severity and can be performed safely when paying careful attention to the closure of the cricothyroid membrane....

  4. Small Incision Cataract Surgery (SICS with Clear Corneal Incision and SICS with Scleral Incision – A Comparative Study

    Directory of Open Access Journals (Sweden)

    Md Shafiqul Alam

    2014-01-01

    Full Text Available Background: Age related cataract is the leading cause of blindness and visual impairment throughout the world. With the advent of microsurgical facilities simple cataract extraction surgery has been replaced by small incision cataract surgery (SICS with posterior chamber intra ocular lens implant, which can be done either with clear corneal incision or scleral incision. Objective: To compare the post operative visual outcome in these two procedures of cataract surgery. Materials and method: This comparative study was carried out in the department of Ophthalmology, Delta Medical College & Hospital, Dhaka, Bangladesh, during the period of January 2010 to December 2012. Total 60 subjects indicated for age related cataract surgery irrespective of sex with the age range of 40-80 years with predefined inclusion and exclusion criteria were enrolled in the study. Subjects were randomly and equally distributed in 2 groups; Group A for SICS with clear corneal incision and group B for SICS with scleral incision. Post operative visual out come was evaluated by determining visual acuity and astigmatism in different occasions and was compared between groups. Statistical analysis was done by SPSS for windows version12. Results: The highest age incidence (43.3% was found between 61 to 70 years of age group. Among study subjects 40 were male and 20 were female. Preoperative visual acuity and astigmatism were evenly distributed between groups. Regarding postoperative unaided visual outcome, 6/12 or better visual acuity was found in 19.98% cases in group A and 39.6% cases in group B at 1st week. At 6th week 6/6 vision was found in 36.3% in Group A and 56.1% in Group B and 46.2% in group A and 66% in group B without and with correction respectively. With refractive correction, 6/6 vision was attained in 60% subjects of group A and 86.67% of group B at 8th week. Post operative visual acuity was statistically significant in all occasions. Postoperative astigmatism of

  5. Therapeutic benefits of carbon dioxide (CO2) laser on single-site HPV lesions in the lower female genital tract

    Science.gov (United States)

    Urru, Giovanni; Moretti, Gianfranco

    1998-01-01

    Numerous studies have shown contradictory variable percentages of recurrent HPV lesions, after various therapies. The present study therefore evaluates the effectiveness of CO2 laser vaporization in the treatment of single-site HPV lesions of the lower female genital tract in order to confirm the conviction that physical therapy alone, in agreement with some findings reported in the literature, is capable of guaranteeing a high cure rate in selected patients. From January 1995 to June 1996, seventy- five female patients were treated with CO2 laser vaporization for single-site genital HPV lesions, some of which were associated with low-grade intra-epithelial neoplasia. The success rate after 12 months proved to be 97%. The pre-existing clinical symptoms disappeared in all the patients treated. No complication in the vaporization procedure was encountered.

  6. Treatment of acne scarring using a dual-spot-size ablative fractionated carbon dioxide laser: review of the literature.

    Science.gov (United States)

    Tierney, Emily P

    2011-07-01

    Fractional photothermolysis has been reported in the literature to improve pigmentary and textural changes associated with acne scarring. To review the literature for the treatment of acne scarring using nonablative fractional laser (NAFL) and ablative fractional laser (AFL) resurfacing. Review of the Medline literature evaluating NAFL and AFL for acne scarring. NAFL and AFL are safe and effective treatments for acne scarring. It is likely that the controlled, limited dermal heating of fractional resurfacing initiates a cascade of events in which normalization of the collagenesis-collagenolysis cycle occurs. We present the results of a patient treated using a novel dual-spot-size AFL device. Three months after the final treatment, the patient reported 75% improvement in acne scarring and 63% overall improvement in photoaging. Fractionated resurfacing for the treatment of acne scarring is associated with lesser risks of side effects of prolonged erythema and risks of delayed-onset dyspigmentation and scarring which complicate traditional ablative laser resurfacing approaches. We present herein preliminary data suggesting that a dual-spot-size AFL device presents novel advantages of improving texture and pigmentation in acne scarring and photoaging. © 2011 by the American Society for Dermatologic Surgery, Inc.

  7. Problems and complications of full-face carbon dioxide laser resurfacing for pathological lesions of the skin.

    Science.gov (United States)

    Read-Fuller, Andrew M; Yates, David M; Vu, David D; Hoopman, John E; Finn, Richard A

    2017-01-01

    Facial resurfacing with a CO 2 laser has been used for treatment of pathologic lesions and for cosmetic purposes. Postoperative complications and problems after laser resurfacing include infections, acneiform lesions, and pigment changes. This retrospective study describes the most common problems and complications in 105 patients and assesses postoperative pain in 38 patients. All patients received CO 2 laser resurfacing for treatment of malignant/premalignant lesions and had postoperative follow-up to assess problems and complications. Some had follow-up to assess postoperative pain. All patients had Fitzpatrick I-III skin types and underwent the same perioperative care regimen. There were 11 problems and 2 complications. Problems included infection, acneiform lesion/milia, and uncontrolled postoperative pain. Complications included hyperpigmentation. Among the postoperative pain group, 53% reported no pain and the rest had mild or moderate pain. Complications are rare. Infection and acneiform lesions/milia were the most common problems, as previously reported. Most patients do not experience postoperative pain. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. The boomerang incision for periareolar breast malignancies.

    Science.gov (United States)

    Tan, Mona P

    2007-11-01

    Breast-conservation surgery has been shown to be equivalent to mastectomy in terms of long-term survival for the treatment of breast cancer. Various techniques have been described on how to achieve clear margins and good cosmetic outcomes and therefore expand the indications for breast conservation. A novel incision is detailed to augment the options already available.

  9. Single scrotal incision orchidopexy for palpable undescended

    International Nuclear Information System (INIS)

    Ahmad, A.; Safdar, C.A.; Yasir, U.; Rasool, N.; Kanwal, S.; Boota, M.; Rehman, J.U.

    2014-01-01

    To retrospectively asses the results of single scrotal incision orchidopexy (SSIO) performed at our centre with ligation of the patent processus vaginalis in children having palpable undescended testes (UDT). Study Design: Quasi-experimental with retrospective data. Place and Duration of Study: Department of Paediatric surgery Military Hospital Rawalpindi, from April 2007 to December 2011. Patients and Methods: After making a single transverse incision at superior scrotal border, the testis was identified; gubernaculums and the sac were dissected to the highest level and divided. The testis was placed into the scrotum and fixed to the scrotal fascia/skin. All patients were assessed at 2 weeks, 2 months and 6 months post operatively, and then yearly. Results: A total of 38 orchidopexies were performed in 33 patients. The patients age ranged from 14 months to 7 years (mean:2.1 years). Bilateral UDT were found in 5 patients (15.1%). Operative time ranged from 20 to 45 minutes (mean: 36 minutes). The single scrotal incision technique was successful in all 38 cases (100%). All testes were easily fixed in the scrotum. Two patients (5.2%) developed scrotal haematoma and one patient (2.6%) developed stitch abscess. All showed good an atomical and cosmetic results up to a minimum of six months of follow-up. Conclusion: Single scrotal incision orchidopexy for palpable undescended testis is a simple and safe technique. It has shown to consume shorter time and give good cosmetic results. (author)

  10. Field Results from Three Campaigns to Validate the Performance of the Miniaturized Laser Heterodyne Radiometer (Mini-LHR) for Measuring Carbon Dioxide and Methane in the Atmospheric Column

    Science.gov (United States)

    Miller, J. Houston; Clarke, Greg B.; Melroy, Hilary; Ott, Lesley; Steel, Emily Wilson

    2014-01-01

    In a collaboration between NASA GSFC and GWU, a low-cost, surface instrument is being developed that can continuously monitor key carbon cycle gases in the atmospheric column: carbon dioxide (CO2) and methane (CH4). The instrument is based on a miniaturized, laser heterodyne radiometer (LHR) using near infrared (NIR) telecom lasers. Despite relatively weak absorption line strengths in this spectral region, spectrallyresolved atmospheric column absorptions for these two molecules fall in the range of 60-80% and thus sensitive and precise measurements of column concentrations are possible. In the last year, the instrument was deployed for field measurements at Park Falls, Wisconsin; Castle Airport near Atwater, California; and at the NOAA Mauna Loa Observatory in Hawaii. For each subsequent campaign, improvement in the figures of merit for the instrument has been observed. In the latest work the absorbance noise is approaching 0.002 optical density (OD) noise on a 1.8 OD signal. An overview of the measurement campaigns and the data retrieval algorithm for the calculation of column concentrations will be presented. For light transmission through the atmosphere, it is necessary to account for variation of pressure, temperature, composition, and refractive index through the atmosphere that are all functions of latitude, longitude, time of day, altitude, etc. For temperature, pressure, and humidity profiles with altitude we use the Modern-Era Retrospective Analysis for Research and Applications (MERRA) data. Spectral simulation is accomplished by integrating short-path segments along the trajectory using the SpecSyn spectral simulation suite developed at GW. Column concentrations are extracted by minimizing residuals between observed and modeled spectrum using the Nelder-Mead simplex algorithm. We will also present an assessment of uncertainty in the reported concentrations from assumptions made in the meteorological data, LHR instrument and tracker noise, and radio

  11. Radiological findings after endoscopic incision of ureterocele

    International Nuclear Information System (INIS)

    Cheon, Jung Eun; Kim, In One; Seok, Eul Hye; Cha, Joo Hee; Choi, Gook Myung; Kim, Woo Sun; Yeon, Kyung Mo; Kim, Kwang Myung; Choi, Hwang; Cheon, Jung Eun; Seok, Eul Hye; Cha, Joo Hee; Choi, Guk Myung

    2001-01-01

    Endoscopic incision of ureterocele is considered a simple and safe method for decompression of urinary tract obstruction above ureterocele. The purpose of this study was to evaluate the radiological findings after endoscopic incision of ureterocele. We retrospectively reviewed the radiological findings (ultrasonography (US), intravenous urography, and voiding cystourethrography(VCU)) in 16 patients with ureterocele who underwent endoscopic incision (mean age at surgery, 15 months; M:F 3:13; 18 ureteroceles). According to the postoperative results, treatment was classified as successful when medical treatment was still required, and second operation when additional surgical treatment was required. Postoperative US (n=10) showed that in all patients, urinary tract obstruction was relieved: the kidney parenchima was thicker and the ureterocele was smaller. Intravenous urography (n=8), demonstrated that in all patients, urinary tract obstruction and the excretory function of the kidney had improved. Postoperative VCU indicated that in 92% of patients (12 of 13), endoscopic incision of the ureterocele led to vesicoureteral reflux(VUR). Of these twelve, seven (58%) showed VUR of more than grade 3, while newly developed VUR was seen in five of eight patients (63%) who had preoperative VCU. Surgery was successful in four patients (25%), partially successful in three (19%), and a second operation-on account of recurrent urinary tract infection and VUR of more than grase 3 during the follow-up period-was required by nine (56%). Although endoscopic incision of a ureterocele is a useful way of relieving urinary tract obstruction, an ensuing complication may be VUR. Postoperative US and intravenous urography should be used to evaluate parenchymal change in the kidney and improvement of uronary tract obstructon, while to assess the extend of VUR during the follow-up period , postoperative VCU is required

  12. Bartholin's gland cysts: management with carbon-dioxide laser vaporization Cistos da glândula de Bartholin: tratamento com vaporização laser com CO2

    Directory of Open Access Journals (Sweden)

    Ana Cristina Neves Figueiredo

    2012-12-01

    Full Text Available PURPOSE: To evaluate the effectiveness, recurrence rate, and complications of carbon-dioxide laser vaporization in the treatment of Bartholin's gland cysts. METHODS: A retrospective study including 127 patients with symptomatic Bartholin' gland cysts submitted to carbon-dioxide laser vaporization at our institution from January 2005 to June 2011. Patients with Bartholin's gland abscesses and those suspected of having neoplasia were excluded. All procedures were performed in an outpatient setting under local anaesthesia. Clinical records were reviewed for demographic characteristics, anatomic parameters, intraoperative and postoperative complications, and follow-up data. Data were stored and analyzed in Microsoft Excel® 2007 software. A descriptive statistical analysis was performed, and its results were expressed as frequency (percentage or mean±standard deviation. Complication, recurrence, and cure rates were calculated. RESULTS: The mean age of the patients was 37.3±9.5 years-old (range from 18 to 61 years-old. Seventy percent (n=85 of them were multiparous. The most common symptom was pain and 47.2% (n=60 of patients had a history of previous medical and/or surgical treatment for Bartholin's gland abscesses. Mean cyst size was 2.7±0.9 cm. There were three (2.4% cases of minor intraoperative bleeding. Overall, there were 17 (13.4% recurrences within a mean of 14.6 months (range from 1 to 56 months: ten Bartholin's gland abscesses and seven recurrent cysts requiring reintervention. The cure rate after single laser treatment was 86.6%. Among the five patients with recurrent disease that had a second laser procedure, the cure rate was 100%. CONCLUSIONS: At this institution, carbon-dioxide laser vaporization seems to be a safe and effective procedure for the treatment of Bartholin's gland cysts.OBJETIVO: Avaliar a eficácia, a taxa de recorrência e as complicações da vaporização laser com CO2 no tratamento dos cistos da glândula de

  13. Fractional carbon dioxide laser resurfacing of rhytides and photoaged skin--a prospective clinical study on patient expectation and satisfaction.

    Science.gov (United States)

    Kohl, Elisabeth; Meierhöfer, Julia; Koller, Michael; Zeman, Florian; Groesser, Leopold; Karrer, Sigrid; Hohenleutner, Ulrich; Landthaler, Michael; Hohenleutner, Silvia

    2015-02-01

    Fractional CO2 -laser resurfacing is increasingly used for treating rhytides and photoaged skin because of its favorable benefit-risk ratio. A key outcome measure and treatment goal in aesthetic laser therapy is patient satisfaction. However, few data are available on patient-reported outcomes after fractional ablative skin-resurfacing. To compare patient expectations before and patient satisfaction after three fractional CO2 -laser treatments and to correlate objectively measured wrinkle reduction with patient satisfaction after treatment. We investigated patient expectation and satisfaction using a 14-item questionnaire in 24 female patients. We assessed the skin-related quality of life and patient satisfaction with skin appearance. We profilometrically measured wrinkle size in four facial areas before and three months after treatment and investigated correlations between wrinkle reduction and patient satisfaction. The high patient expectations before treatment (ceiling effect) were actually slightly exceeded. The average score of 14 items delineating patient satisfaction with laser treatment was higher (4.64 ± 0.82; n = 24) than the respective expectations before treatment (4.43 ± 0.88; n = 24). Skin-related quality of life and patient satisfaction with skin appearance had significantly improved after the last treatment. Patients dissatisfied with their skin appearance before treatment (mean 2.1 ± 1.5; evaluated on a scale ranging from 0-6) were satisfied (mean 5.1 ± 1.2) (P skin appearance at the follow-up. Patient satisfaction with skin appearance was not correlated to the profilometrically measured reduction of wrinkle size of any facial area. Our results show high patient satisfaction with ablative fractional skin resurfacing, also regarding improved self-esteem and self-satisfaction despite high pre-treatment expectations. Skin-specific quality of life had significantly improved. Thus, this treatment modality can be recommended

  14. Comparison of a fractional microplasma radio frequency technology and carbon dioxide fractional laser for the treatment of atrophic acne scars: a randomized split-face clinical study.

    Science.gov (United States)

    Zhang, Zhen; Fei, Ye; Chen, Xiangdong; Lu, Wenli; Chen, Jinan

    2013-04-01

    No studies have compared fractional microplasma radio frequency (RF) technology with the carbon dioxide fractional laser system (CO2 FS) in the treatment of atrophic acne scars in the same patient. To compare the efficacy and safety of fractional microplasma RF with CO2 FS in the treatment of atrophic acne scars. Thirty-three Asian patients received three sessions of a randomized split-face treatment of fractional microplasma RF or CO2 FS. Both modalities had a roughly equivalent effect. Échelle d'Évaluation Clinique Des Cicatrices d'Acné scores were significantly lower after fractional microplasma RF (from 51.1 ± 14.2 to 22.3 ± 8.6, 56.4% improvement) and CO2 FS (from 48.8 ± 15.1 to 19.9 ± 7.9, 59.2% improvement) treatments. There was no statistically significant difference between the two therapies. Twelve subjects (36.4%) experienced postinflammatory hyperpigmentation (PIH) after 30 of 99 treatment sessions (30.3%) on the CO2 FS side and no PIH was observed on the fractional microplasma RF sides. Both modalities have good effects on treating atrophic scars. PIH was not seen with the fractional microplasma RF, which might make it a better choice for patients with darker skin. © 2013 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  15. Treatment of acne scars and wrinkles in asian patients using carbon-dioxide fractional laser resurfacing: its effects on skin biophysical profiles.

    Science.gov (United States)

    Hwang, Young Ji; Lee, Yu Na; Lee, Yang Won; Choe, Yong Beom; Ahn, Kyu Joong

    2013-11-01

    Although ablative fractional resurfacing is known to be effective against photoaging and acne scars, studies on its efficacy, safety and changes in the skin characteristics of Asians are limited. The aim of this study is to assess the efficacy and safety of carbon dioxide fractional laser (CO2FL) in Koreans treated for wrinkles and acne scars, and to define the changes in skin characteristics during recovery period. We administered one session of CO2FL on 10 acne scar patients and 14 wrinkles patients with skin types IV and V. The surveillance of efficacy and side effects along with the measurement of biophysical properties was carried out before 1 day, 1 week, 1 month and 3 months after treatment. Using a non-invasive method, skin barrier damage, erythema and bronzing of skin during the recovery period were assessed, and all of the items eventually returned to the pre-treatment level. Skin elasticity was measured in the wrinkle group, and the statistically significant effect was sustained throughout the next three months. The outcome of treatment was found to be better than 'moderate improvement' in both the acne scar and wrinkle groups. Further, there were no serious side effects three months post-procedure. CO2 FL is thought to be an effective and safe method for treating moderate to severe acne scars and wrinkles in Asians.

  16. The Effect of Conditioned Media of Adipose-Derived Stem Cells on Wound Healing after Ablative Fractional Carbon Dioxide Laser Resurfacing

    Science.gov (United States)

    Zhou, Bing-Rong; Xu, Yang; Guo, Shi-Lei; Xu, Yan; Wang, Ying; Zhu, Fen; Wu, Di; Yin, Zhi-Qiang; Luo, Dan

    2013-01-01

    Objective. To evaluate the benefits of conditioned medium of Adipose-derived stem cells (ADSC-CM) on wound healing after fractional carbon dioxide laser resurfacing (FxCR) on human skin. Materials and Methods. Nineteen subjects were treated with FxCR on the bilateral inner arms. ADSC-CM was applied on FxCR site of one randomly selected arm. Transepidermal water loss (TEWL), skin color, and gross-elasticity of FxCR site on both arms were measured. Skin samples were taken by biopsy from three subjects 3 weeks after treatment for histopathological manifestations and mRNA expressions of procollagen types I and III, elastin genes were noted. Results. The index of erythema, melanin, and TEWL of the ADSC-CM-treated skin were significantly lower than those of the control side. The mRNA expression of type III procollagen in ADSC-CM-treated group at 3 weeks posttreatment was 2.6 times of that of the control group. Conclusion. Application of allograft ADSC-CM is an effective method for enhancing wound healing after FxCR, by reducing transient adverse effects such as erythema, hyperpigmentation, and increased TEWL. PMID:24381938

  17. The Effect of Conditioned Media of Adipose-Derived Stem Cells on Wound Healing after Ablative Fractional Carbon Dioxide Laser Resurfacing

    Directory of Open Access Journals (Sweden)

    Bing-Rong Zhou

    2013-01-01

    Full Text Available Objective. To evaluate the benefits of conditioned medium of Adipose-derived stem cells (ADSC-CM on wound healing after fractional carbon dioxide laser resurfacing (FxCR on human skin. Materials and Methods. Nineteen subjects were treated with FxCR on the bilateral inner arms. ADSC-CM was applied on FxCR site of one randomly selected arm. Transepidermal water loss (TEWL, skin color, and gross-elasticity of FxCR site on both arms were measured. Skin samples were taken by biopsy from three subjects 3 weeks after treatment for histopathological manifestations and mRNA expressions of procollagen types I and III, elastin genes were noted. Results. The index of erythema, melanin, and TEWL of the ADSC-CM-treated skin were significantly lower than those of the control side. The mRNA expression of type III procollagen in ADSC-CM-treated group at 3 weeks posttreatment was 2.6 times of that of the control group. Conclusion. Application of allograft ADSC-CM is an effective method for enhancing wound healing after FxCR, by reducing transient adverse effects such as erythema, hyperpigmentation, and increased TEWL.

  18. Safe and effective one-session fractional skin resurfacing using a carbon dioxide laser device in super-pulse mode: a clinical and histologic study.

    Science.gov (United States)

    Trelles, Mario A; Shohat, Michael; Urdiales, Fernando

    2011-02-01

    Carbon dioxide (CO(2)) laser ablative fractional resurfacing produces skin damage, with removal of the epidermis and variable portions of the dermis as well as associated residual heating, resulting in new collagen formation and skin tightening. The nonresurfaced epidermis helps tissue to heal rapidly, with short-term postoperative erythema. The results for 40 patients (8 men and 32 women) after a single session of a fractional CO(2) resurfacing mode were studied. The treatments included resurfacing of the full face, periocular upper lip, and residual acne scars. The patients had skin prototypes 2 to 4 and wrinkle degrees 1 to 3. The histologic effects, efficacy, and treatment safety in various clinical conditions and for different phototypes are discussed. The CO(2) laser for fractional treatment is used in super-pulse mode. The beam is split by a lens into several microbeams, and super-pulse repetition is limited by the pulse width. The laser needs a power adaptation to meet the set fluence per microbeam. Laser pulsing can operate repeatedly on the same spot or be moved randomly over the skin, using several passes to achieve a desired residual thermal effect. Low, medium, and high settings are preprogrammed in the device, and they indicate the strength of resurfacing. A single treatment was given with the patient under topical anesthesia. However, the anesthesia was injected on areas of scar tissue. Medium settings (2 Hz, 30 W, 60 mJ) were used, and two passes were made for dark skins and degree 1 wrinkles. High settings (2 Hz, 60 W, 120 mJ) were used, and three passes were made for degree 3 wrinkles and scar tissue. Postoperatively, resurfaced areas were treated with an ointment of gentamycin, Retinol Palmitate, and DL-methionine (Novartis; Farmaceutics, S.A., Barcelona, Spain). Once epithelialization was achieved, antipigment and sun protection agents were recommended. Evaluations were performed 15 days and 2 months after treatment by both patients and

  19. Incision integrity and postoperative outcomes after microcoaxial phacoemulsification performed using 2 incision-dependent systems.

    Science.gov (United States)

    Vasavada, Vaishali; Vasavada, Abhay R; Vasavada, Viraj A; Srivastava, Samaresh; Gajjar, Devarshi U; Mehta, Siddharth

    2013-04-01

    To compare incision integrity and clinical outcomes of 2 microcoaxial phacoemulsification systems. Iladevi Cataract & IOL Research Centre, Ahmedabad, India. Prospective randomized clinical trial. Eyes were randomized to have phacoemulsification using a 1.8 mm clear corneal incision (CCI) system (Group 1, Stellaris system) or a 2.2 mm CCI system (Group 2, Intrepid Infiniti system). Incision enlargement at end of surgery was measured. At the conclusion of surgery, trypan blue was applied over the conjunctival surface, anterior chamber aspirate withdrawn, and ingress into anterior chamber measured. Postoperative observations included evaluation of the CCI using anterior segment optical coherence tomography (AS-OCT), change in central corneal thickness (CCT), and anterior segment inflammation at 1 day, 1 week, and 1 month and endothelial cell loss and surgically induced astigmatism (SIA) at 3 months. Incision enlargement (P.05). At the end of surgery, it is not the initial incision size alone but also the distortion of the incision during subsequent stages of surgery that determine the integrity of the CCI. Copyright © 2013 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  20. COMPARISON OF POSTOP SIA IN MSICS WITH STRAIGHT INCISION VERSUS FROWN INCISION

    Directory of Open Access Journals (Sweden)

    Shayana Bhumbla

    2017-05-01

    Full Text Available BACKGROUND Surgically-Induced Astigmatism (SIA is one of the commonest causes of poor postoperative vision even after uneventful cataract surgery. Recent advances have led to a newer concept of “refractive cataract surgery.” The aim of the study is to study the comparison of postop SIA in Manual Small Incision Cataract Surgery (MSICS with straight versus frown incision. MATERIALS AND METHODS 50 patients of cataract were divided into 2 groups (25 each - group A underwent MSICS with 6 mm straight incision, group B underwent MSICS with 6 mm frown incision. BCVA, keratometry readings were recorded with auto kerato-refractometer preop, at 1 week, 1 month, 3 months and SIA was calculated with SIA calculator version 2.1, a free software program. RESULTS Mean SIA in group A and B were - 1.14D versus 0.92D at 1 week; 1.26D versus 0.97D at 1 month; 1.29D versus 0.95D at 3 months. The difference was statistically significant at each follow up visit (p<0.05. CONCLUSION Frown incision gives lesser SIA than straight incision in MSICS.

  1. Comparison of efficacy of carbon dioxide (CO/sub 2/) laser with cutting diathermy in surgical excision of early carcinoma tongue

    International Nuclear Information System (INIS)

    Rashid, M.; Hashmi, M.A.; Dastigir, M.

    2015-01-01

    To compare the efficacy of carbon dioxide (CO/sub 2/) laser with cutting diathermy as a cutting device in surgical excision of early carcinoma tongue. Study Design: Experimental study. Place and Duration of Study: Combined Military Hospital (CMH), Rawalpindi and CMH, Lahore, from July 2008 to July 2011. Methodology: Twenty two biopsy proven cases of T1 and early T2 squamous cell carcinoma of tongue were divided in two equal groups of 11 each labeled as A and B. Tumor was excised by CO/sub 2/ laser in group A while cutting diathermy was done in group B. For both groups tumor excision time, per-operative blood loss, postoperative oral swelling and pain was recorded. Excision time of tumor was assessed in minutes and amount of blood loss in milliliters till complete hemostasis after removal of primary tumor. Postoperatively patients were assessed on 12 hourly basis for 48 hours for pain. Pain was analyzed on visual analogue score 1 - 10. Oral swelling was assessed once after 24 hours and labeled as mild, moderate and severe. Independent sample t-test was applied for analysis of excision time, postoperative pain and per-operative blood loss for both groups. Postoperative swelling was analyzed using Fisher exact test. P-value of < 0.05 was considered significant. Results: The mean age at diagnosis in group A was 49.36 ± 5.27 years, while in group B patients had mean age of 50.73 ± 8.13 years. In group A, 4/11 (36.3%) patients were having tumor stage T1 while 7/11 (63.6%) had T2 stage tumor. In group B, 5/11 (45.4%) were having T1 and 6/11 (54.5%) were having stage T2 tumor. Excision time was significantly shorter for group B (p=0.003), but group A had less postoperative pain (p=0.001), less per-operative blood loss (p=0.001) and less postoperative oral swelling (p=0.021). Conclusion: Early carcinoma tongue is better removed by laser than electrocautery in terms of postoperative morbidity, per-operative blood loss, postoperative pain and oral swelling. (author)

  2. Current Status of Single-incision Laparoscopic Surgery

    DEFF Research Database (Denmark)

    Ahmed, Irfan; Ciancio, Fabio; Ferrara, Vincenzo

    2012-01-01

    Recent advances in minimally invasive surgery have centered on reducing the number of incisions required, which has led to the development of the single-incision laparoscopic technique. A panel of European single-incision laparoscopy experts met to discuss the current status of, and the future...

  3. Higher Incision at Upper Part of Lower Segment Caesarean Section

    Directory of Open Access Journals (Sweden)

    Yong Shao

    2014-06-01

    Conclusions: An incision at the upper part of the lower segment reduces blood loss, enhances uterine retraction, predisposes to fewer complications, is easier to repair, precludes bladder adhesion to the suture line and reduces operation time. Keywords: caesarean section; higher incision technique; traditional uterine incision technique.

  4. Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective study.

    Science.gov (United States)

    Sekundo, Walter; Kunert, Kathleen S; Blum, Marcus

    2011-03-01

    This 6 month prospective multi-centre study evaluated the feasibility of performing myopic femtosecond lenticule extraction (FLEx) through a small incision using the small incision lenticule extraction (SMILE) procedure. Prospective, non-randomised clinical trial. PARTICIPANTS; Ninety-one eyes of 48 patients with myopia with and without astigmatism completed the final 6 month follow-up. The patients' mean age was 35.3 years. Their preoperative mean spherical equivalent (SE) was −4.75±1.56 D. A refractive lenticule of intrastromal corneal tissue was cut utilising a prototype of the Carl Zeiss Meditec AG VisuMax femtosecond laser system. Simultaneously two opposite small ‘pocket’ incisions were created by the laser system. Thereafter, the lenticule was manually dissected with a spatula and removed through one of incisions using modified McPherson forceps. Uncorrected visual acuity (UCVA) and best spectacle corrected visual acuity (BSCVA) after 6 months, objective and manifest refraction as well as slit-lamp examination, side effects and a questionnaire. Six months postoperatively the mean SE was −0.01 D±0.49 D. Most treated eyes (95.6%) were within ±1.0 D, and 80.2% were within ±0.5 D of intended correction. Of the eyes treated, 83.5% had an UCVA of 1.0 (20/20) or better, 53% remained unchanged, 32.3% gained one line, 3.3% gained two lines of BSCVA, 8.8% lost one line and 1.1% lost ≥2 lines of BSCVA. When answering a standardised questionnaire, 93.3% of patients were satisfied with the results obtained and would undergo the procedure again. SMILE is a promising new flapless minimally invasive refractive procedure to correct myopia.

  5. Absorption spectroscopic studies of carbon dioxide conversion in a low pressure glow discharge using tunable infrared diode lasers

    International Nuclear Information System (INIS)

    Hempel, F; Roepcke, J; Miethke, F; Wagner, H-E

    2002-01-01

    The time and spatial dependence of the chemical conversion of CO 2 to CO were studied in a closed glow discharge reactor (p = 50 Pa, I = 2-30 mA) consisting of a small plasma zone and an extended stationary afterglow. Tunable infrared diode laser absorption spectroscopy has been applied to determine the absolute ground state concentrations of CO and CO 2 . After a certain discharge time an equilibrium of the concentrations of both species could be observed. The spatial dependence of the equilibrium CO concentration in the afterglow was found to be varying less than 10%. The feed gas was converted to CO more predominantly between 43% and 60% with increasing discharge current, forming so-called quasi-equilibrium states of the stable reaction products. The formation time of the stable gas composition also decreased with the current. For currents higher than 10 mA the conversion rate of CO 2 to CO was estimated to be 1.2x10 13 molecules J -1 . Based on the experimental results, a plasma chemical modelling has been established

  6. Rapid vibrational and rotational energy-transfer rates in heated carbon dioxide collisions by double-resonance laser spectroscopy

    International Nuclear Information System (INIS)

    Thomason, M.D.

    1982-07-01

    Rates for resonant vibrational and rotational energy transfer from the 001 state by CO 2 + CO 2 collisions have been measured. All data were obtained by double resonance spectroscopy with CO 2 lasers in a 2.5 meter absorption cell at 700 0 K. Results for rotation transfer include pumped-level relaxation and the response of other 001 levels with ΔJ up to 18. These data are compared to four relevant collision models via a 35-level rate equation analysis. Sequence-band (002 → 101) and hot-band (011 → 110) lasting have been used to observe resonant nu 3 -transfer relaxation involving 001 + 001 reversible 002 + 000, 001 + 100 reversible 101 + 000, and 001 + 010 reversible 011 + 000. A multilevel rate analysis has been utilized to determine the rate coefficients for 001 going to the 002, the 101, and the 011 levels. Part of the hot-band data has been interpreted as due to 110 + 000 reversible 100 + 010, and the associated rate constant has been estimated. The results of the study are compared to the theory and to other experiments

  7. Optimization of conditions for growth of vanadium dioxide thin films on silicon by pulsed-laser deposition

    Science.gov (United States)

    Shibuya, Keisuke; Sawa, Akihito

    2015-10-01

    We systematically examined the effects of the substrate temperature (TS) and the oxygen pressure (PO2) on the structural and optical properties polycrystalline V O2 films grown directly on Si(100) substrates by pulsed-laser deposition. A rutile-type V O2 phase was formed at a TS ≥ 450 °C at PO2 values ranging from 5 to 20 mTorr, whereas other structures of vanadium oxides were stabilized at lower temperatures or higher oxygen pressures. The surface roughness of the V O2 films significantly increased at growth temperatures of 550 °C or more due to agglomeration of V O2 on the surface of the silicon substrate. An apparent change in the refractive index across the metal-insulator transition (MIT) temperature was observed in V O2 films grown at a TS of 450 °C or more. The difference in the refractive index at a wavelength of 1550 nm above and below the MIT temperature was influenced by both the TS and PO2, and was maximal for a V O2 film grown at 450 °C under 20 mTorr. Based on the results, we derived the PO2 versus 1/TS phase diagram for the films of vanadium oxides, which will provide a guide to optimizing the conditions for growth of V O2 films on silicon platforms.

  8. Optimization of conditions for growth of vanadium dioxide thin films on silicon by pulsed-laser deposition

    Directory of Open Access Journals (Sweden)

    Keisuke Shibuya

    2015-10-01

    Full Text Available We systematically examined the effects of the substrate temperature (TS and the oxygen pressure (PO2 on the structural and optical properties polycrystalline V O2 films grown directly on Si(100 substrates by pulsed-laser deposition. A rutile-type V O2 phase was formed at a TS ≥ 450 °C at PO2 values ranging from 5 to 20 mTorr, whereas other structures of vanadium oxides were stabilized at lower temperatures or higher oxygen pressures. The surface roughness of the V O2 films significantly increased at growth temperatures of 550 °C or more due to agglomeration of V O2 on the surface of the silicon substrate. An apparent change in the refractive index across the metal–insulator transition (MIT temperature was observed in V O2 films grown at a TS of 450 °C or more. The difference in the refractive index at a wavelength of 1550 nm above and below the MIT temperature was influenced by both the TS and PO2, and was maximal for a V O2 film grown at 450 °C under 20 mTorr. Based on the results, we derived the PO2 versus 1/TS phase diagram for the films of vanadium oxides, which will provide a guide to optimizing the conditions for growth of V O2 films on silicon platforms.

  9. Single-Incision Laparoscopic Sterilization of the Cheetah (Acinonyx jubatus).

    Science.gov (United States)

    Hartman, Marthinus J; Monnet, Eric; Kirberger, Robert M; Schmidt-Küntzel, Anne; Schulman, Martin L; Stander, Jana A; Stegmann, George F; Schoeman, Johan P

    2015-07-01

    To describe laparoscopic ovariectomy and salpingectomy in the cheetah (Acinonyx jubatus) using single-incision laparoscopic surgery (SILS). Prospective cohort. Female cheetahs (Acinonyx jubatus) (n = 21). Cheetahs were randomly divided to receive either ovariectomy (n = 11) or salpingectomy (n = 10). The use and complications of a SILS port was evaluated in all of cheetahs. Surgery duration and insufflation volumes of carbon dioxide (CO2 ) were recorded and compared across procedures. Laparoscopic ovariectomy and salpingectomy were performed without complications using a SILS port. The poorly-developed mesosalpinx and ovarian bursa facilitated access to the uterine tube for salpingectomy in the cheetah. The median surgery duration for ovariectomy was 24 minutes (interquartile range 3) and for salpingectomy was 19.5 minutes (interquartile range 3) (P = .005). The median volume of CO2 used for ovariectomy was 11.25 L (interquartile range 3.08) and for salpingectomy was 4.90 L (interquartile range 2.52), (P = .001) CONCLUSIONS: Laparoscopic ovariectomy and salpingectomy can be performed in the cheetah using SILS without perioperative complications. Salpingectomy is faster than ovariectomy and requires less total CO2 for insufflation. © Copyright 2015 by The American College of Veterinary Surgeons.

  10. Small incision guarded hydroaspiration of iris lesions.

    Science.gov (United States)

    Singh, Arun D

    2017-11-01

    To describe the technique and results of a minimally invasive surgical technique for resection of small iris lesions. Consecutive case series of 22 patients with localised, small iris lesions that were resected using the described surgical technique that composed of multiple, small corneal incisions created to allow for internal iris resection with 23-gauge horizontal vitrectomy scissors, followed by guarded tumour aspiration through a clear plastic tubing (diameter 3.5 mm) primed with viscoelastic agent. The mean largest basal diameter was 3.0 mm (range 1.5-5.0 mm; median 3.0 mm) and mean thickness was 1.3 mm (range 0.5-2.5 mm; median 1.0 mm). Use of multiple (2-4) small corneal incisions (range 2.0-3.0 mm; mean 2.8 mm) allowed reduced postoperative morbidity (significant hyphema (0%), hypotony (0%), wound leak (0%), >2 line change in best corrected visual acuity at postoperative 1 week (4.5%) and mean corneal astigmatism of 1.0 D (range 0.14-2.99 D; median 0.8 D) at postoperative 4-12 weeks. The tumour could be resected with clear surgical margins in all neoplastic cases (benign (2), borderline (1) and malignant (16)). Local recurrence or metastases were not observed in any melanoma case over a mean follow-up of 33.0 months (range 1.0-90.0 months; median 33.5 months). Small incision guarded hydroaspiration is a minimally invasive surgical technique for resection of select small iris lesions. Use of multiple small corneal incisions avoids morbidity associated with a single large corneoscleral incision, and use of guarded aspiration may eliminate the risk of wound contamination by the malignant tumour. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Outcomes of small incision lenticule extraction (SMILE) in low myopia.

    Science.gov (United States)

    Reinstein, Dan Z; Carp, Glenn I; Archer, Timothy J; Gobbe, Marine

    2014-12-01

    To report the visual and refractive outcomes of small incision lenticule extraction for low myopia using the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany). A retrospective analysis of 120 consecutive small incision lenticule extraction procedures was performed for low myopia. Inclusion criteria were preoperative spherical equivalent refraction up to -3.50 diopters (D), cylinder up to 1.50 D, and corrected distance visual acuity of 20/20 or better. Outcomes analysis was performed for all eyes with 1-year follow-up according to the Standard Graphs for Reporting Refractive Surgery, and also including mesopic contrast sensitivity. One-year data were available for 110 eyes (92%). Preoperatively, mean spherical equivalent refraction was -2.61 ± 0.54 D (range: -1.03 to -3.50 D) and mean cylinder was 0.55 ± 0.38 D (range: 0.00 to 1.50 D). Postoperatively, mean spherical equivalent refraction was -0.05 ± 0.36 D (range: -0.94 to +1.25 D) and mean cylinder was ± 0.50 D in 84% and ± 1.00 D in 99% of eyes. Uncorrected distance visual acuity was 20/20 or better in 96% of eyes and 20/25 or better in 100% of eyes. One line of corrected distance visual acuity was lost in 9%, but no eyes lost two or more lines. There was an initial overcorrection in mean spherical equivalent refraction on day 1 (+0.37 D) as expected, which regressed to +0.10 D at 1 month and -0.05 D at 3 months, after which stability was reached (mean spherical equivalent refraction was -0.05 D at 1 year). Contrast sensitivity at 1 year was slightly increased at 3, 6, 12, and 18 cycles per degree (P < .05). Small incision lenticule extraction for low myopia was found to be safe and effective with outcomes similar to those previously reported for LASIK. Copyright 2014, SLACK Incorporated.

  12. Comparison of electrocautery incision with scalpel incision in midline abdominal surgery - A double blind randomized controlled trial.

    Science.gov (United States)

    Prakash, Lalgudi Dorairajan; Balaji, Nitesh; Kumar, Sathasivam Suresh; Kate, Vikram

    2015-07-01

    To compare the electrocautery incision with scalpel incision in patients undergoing abdominal surgery using a midline incision with respect to incision time, blood loss during incision, postoperative incision site pain and wound infection. Patients undergoing midline abdominal surgery were randomized into electrocautery and scalpel groups. The incision dimensions, incision time and blood loss during incision were noted intraoperatively. Postoperative pain and wound infection were recorded on every postoperative day for one week. 41 patients in each of the two groups were analyzed. Gender and age distribution was similar in both the groups. The mean incision time per unit wound area in the electrocautery group and scalpel group was 9.40 ± 3.37 s/cm(2) and 9.07 ± 3.40 s/cm(2) (p = 0.87) respectively. The mean blood loss per unit wound area was significantly lower in the electrocautery group at 6.46 ± 3.94 ml when compared to that of 23.40 ± 15.28 ml in the scalpel group (p= electrocautery and scalpel groups (14.63% vs. 12.19%; p = 0.347). With a comparable Postoperative incision site pain, wound infection rate and significantly lower blood loss with the equal time taken for the incision, electrocautery can be considered safe and effective in making skin incision in midline laparotomy compared to scalpel incision. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  13. Electrocautery skin incision for neurosurgery procedures--technical note.

    Science.gov (United States)

    Nitta, Naoki; Fukami, Tadateru; Nozaki, Kazuhiko

    2011-01-01

    The reluctance to incise skin with electrocautery is partly attributable to concerns about excessive scarring and poor wound healing. However, recently no difference was reported in wound complications between the cold scalpel and electrocautery scalpel. We assessed the safety and efficacy of electrocautery skin incision in 22 scalp incisions, including 4 cases of reoperation. Electrocautery skin incisions were created using a sharp needle electrode. The generator unit was set on cutting mode, with power of 6 W and 330 kHz sinusoid waveform. Subcutaneous dissections also used the sharp needle electrode, set on coagulating mode, with power of 10 W and 1 MHz pulse-modulated waveform. Galea incisions used a standard blade tip, set on coagulating mode, with power of 20 W and 1 MHz pulse-modulated waveform. Skin incision with the sharp needle electrode caused no charring of the wound. Little bleeding or oozing were observed and skin clips were not necessary. No wound complication such as necrosis or infection occurred. Electrocautery skin incisions for re-operations were also performed safely without complications. Electrocautery skin incision is sufficiently safe procedure not only for first operation but also for re-operation. Electrocautery skin incision is efficacious, especially for extended operation times, because of little blood loss from the edges of skin incision and possible avoidance of skin edge necrosis or alopecia caused by skin clips.

  14. A single incision transaxillary thoracoscopic sympathectomy

    Directory of Open Access Journals (Sweden)

    Marić Nebojša

    2014-01-01

    Full Text Available Background/Aim. Primary hyperhidrosis causes are unknown. The disorder begins in early childhood. It intensifies in puberty and maturity. It is equally present in both sexes. The symptoms exacerbate when the body temperature rises and due to emotional stimuli affecting the sympathetic nerve system. The aim of this study was to demonstrate that videoassisted thoracoscopic surgery (VATS sympathectomy is a method for primary focal hyperhidrosis permanent treatment. The single incision method in properly selected patients maximizes the intervention effectiveness and minimizes aesthetic side effects. Methods. This prospective study analysed the findings in patients who had been operated on due to primary focal hyperhidrosis (face, palms, and armpits using a single small transaxilarry incision in the third inter-rib space at the level of the anterior axillary line with two 5 mm flexible ports. All the patients, with T2-T5 thoracoscopic sympathectomy of the sympathetic chain using a single small incision in the third inter-rib space in the anterior axillary line, were analysed in the period from September 2009 to November 2010 regarding the postoperative morbidity and outcomes of the operation (clinical evaluation and visual analogue scale with a view to assessing the effectiveness of the surgery conducted in this manner. Results. A total of 47 patients (18 men, 29 women, 18 to 48 years old (29 on average had underwent 94 bilateral video-assisted thoracoscopic sympathectomies. The sympathectomy was indicated in cases of facial blushing and sweating (6.38%, palmary sweating (34.04%, axillary sweating (14.89% or both palmary and axillary sweating (44.68%. The largest percentage of patients (98.6% had left the hospital the following day. The postoperative 30 day’s mortality was 0 and the conversion into open surgery was not necessary. As for complications, there had been an occurrence of partial pneumothorax in two patients treated by means of

  15. Flexible single-incision surgery: a fusion technique.

    Science.gov (United States)

    Noguera, José F; Dolz, Carlos; Cuadrado, Angel; Olea, José; García, Juan

    2013-06-01

    The development of natural orifice transluminal endoscopic surgery has led to other techniques, such as single-incision surgery. The use of the flexible endoscope for single-incision surgery paves the way for further refinement of both surgical methods. To describe a new, single-incision surgical technique, namely, flexible single-incision surgery. Assessment of the safety and effectiveness of endoscopic cholecystectomy in a series of 30 patients. This technique consists of a single umbilical incision through which a flexible endoscope is introduced and consists of 2 parallel entry ports that provide access to nonarticulated laparoscopic instruments. The technique was applied in all patients for whom it was prescribed. No general or surgical wound complications were noted. Surgical time was no longer than usual for single-port surgery. Flexible single-incision surgery is a new single-site surgical technique offering the same level of patient safety, with additional advantages for the surgeon at minimal cost.

  16. Single-incision laparoscopic bariatric surgery

    Directory of Open Access Journals (Sweden)

    Huang Chih-Kun

    2011-01-01

    Full Text Available Background: Bariatric surgery has been established as the best option of treatment for morbid obesity. In recent years single-incision laparoscopic surgery (SILS has emerged as another modality of carrying out the bariatric procedures. While SILS represents an advance, its application in morbid obesity at present is limited. In this article, we review the technique and results of SILS in bariatric surgery. Methods: The PubMed database was searched and totally 11 series reporting SILS in bariatric surgery were identified and analyzed. The case reports were excluded. Since 2008, 114 morbidly obese patients receiving SILS bariatric surgeries were reported. Results: The procedures performed included SILS gastric banding, sleeve gastrectomy and gastric bypass. No mortality was reported in the literatures. Sixteen patients (14.05% needed an additional incision for a liver retractor, a trocar or for conversion. Only one complication of wound infection was reported in these series. All the surgeons reported that the patients were highly satisfied with the scar. Conclusion: Because of abundant visceral and subcutaneous fat and multiple comorbidities in morbid obesity, it is more challenging for surgeons to perform the procedures with SILS. It is clear that extensive development of new instruments and technical aspects of these procedures as well as randomized studies to compare them with traditional laparoscopy are essential before these procedures can be utilized in day-to-day clinical practice.

  17. Two-Step Incision for Periarterial Sympathectomy of the Hand

    Directory of Open Access Journals (Sweden)

    Seung Bae Jeon

    2015-11-01

    Full Text Available BackgroundSurgical scars on the palmar surface of the hand may lead to functional and also aesthetic and psychological consequences. The objective of this study was to introduce a new incision technique for periarterial sympathectomy of the hand and to compare the results of the new two-step incision technique with those of a Koman incision by using an objective questionnaire.MethodsA total of 40 patients (17 men and 23 women with intractable Raynaud's disease or syndrome underwent surgery in our hospital, conducted by a single surgeon, between January 2008 and January 2013. Patients who had undergone extended sympathectomy or vessel graft were excluded. Clinical evaluation of postoperative scars was performed in both groups one year after surgery using the patient and observer scar assessment scale (POSAS and the Wake Forest University rating scale.ResultsThe total patient score was 8.59 (range, 6-15 in the two-step incision group and 9.62 (range, 7-18 in the Koman incision group. A significant difference was found between the groups in the total PS score (P-value=0.034 but not in the total observer score. Our analysis found no significant difference in preoperative and postoperative Wake Forest University rating scale scores between the two-step and Koman incision groups. The time required for recovery prior to returning to work after surgery was shorter in the two-step incision group, with a mean of 29.48 days in the two-step incision group and 34.15 days in the Koman incision group (P=0.03.ConclusionsCompared to the Koman incision, the new two-step incision technique provides better aesthetic results, similar symptom improvement, and a reduction in the recovery time required before returning to work. Furthermore, this incision allows the surgeon to access a wide surgical field and a sufficient exposure of anatomical structures.

  18. Lasers

    CERN Document Server

    Milonni, Peter W

    1988-01-01

    A comprehensive introduction to the operating principles and applications of lasers. Explains basic principles, including the necessary elements of classical and quantum physics. Provides concise discussions of various laser types including gas, solid state, semiconductor, and free electron lasers, as well as of laser resonators, diffraction, optical coherence, and many applications including holography, phase conjugation, wave mixing, and nonlinear optics. Incorporates many intuitive explanations and practical examples. Discussions are self-contained in a consistent notation and in a style that should appeal to physicists, chemists, optical scientists and engineers.

  19. Temporal versus Superior Limbal Incision: Any difference in visual ...

    African Journals Online (AJOL)

    Aim: To compare the visual outcome of a superiorly placed limbal incision with a temporal limbal incision in extracapsular cataract surgery. The main outcome measures are visual acuity and the degree of stigmatism based on refraction. Method: A retrospective non randomized comparative study. Medical records of 40 ...

  20. Transurethral incision of urethral diverticulum in the female

    DEFF Research Database (Denmark)

    Miskowiak, J; Honnens de Lichtenberg, M

    1989-01-01

    A new technique of transurethral incision of urethral diverticulum was successfully used in two women. The method described is safe, simple and shortens operating time.......A new technique of transurethral incision of urethral diverticulum was successfully used in two women. The method described is safe, simple and shortens operating time....

  1. Mini transverse versus longitudinal incision in carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Korkmaz, M.; Cepoglu, M.C.

    2013-01-01

    Objective: To evaluate the effectiveness of mini-transverse compared with mini-longitudinal incision for carpal tunnel release (CTR) with reference to postoperative functional capacity, symptom severity and complication rate. Study Design: Analytical study. Place and Duration of Study: Cumhuriyet University Medical Faculty, Department of Orthopaedics, Tokat State Hospital, Department of Orthopaedics and Medical Park Tokat Hospital, Department of Neurosurgery, from January 2007 to January 2009. Methodology: This study included 93 hands of 79 patients with carpal tunnel syndrome (CTS), which were operated between 2007 and 2009. Patients were divided according to incision types into Group-1 (undergoing mini-longitudinal incision) and Group-2 (undergoing mini-transverse incision). Patients were evaluated initially and at 3 weeks after treatment according to symptom severity and functional status of Boston Questionnaire (BQ). Demographic and clinical data were analyzed and compared statistically between two groups. Results: Statistically significant differences were observed in BQ symptom and functional scores between the pre- and postoperative period (p < 0.0001). BQ symptom and functional scores at postoperative period were better in Group-1 than Group-2 (p = 0.044 and p = 0.023 respectively). The scar hypersensitivity (p = 0.258) and tenderness (p = 1.00) associated with the incision sites were not statistically different. Conclusion: Longitudinal incision is more effective on symptom and functional conditions than transverse incision. However, there was less scar formation with transverse incision. (author)

  2. Incisive canal deflation for correct implant placement: case report.

    Science.gov (United States)

    Spin-Neto, Rubens; Bedran, Telma Blanca Lombardo; de Paula, Wagner Nunes; de Freitas, Rubens Moreno; de Oliveira Ramalho, Lizeti Toledo; Marcantonio, Elcio

    2009-12-01

    This article is a case report of a patient in whom the prosthetic planning indicated the necessity of an incisive canal deflation for the correct installation of an implant that is to be osseointegrated. In the reopening phase after the bone graft installation, the incisive canal deflation (biopsy of its content) was done and titanium implants were installed with one of them invading the anatomical space occupied previously by the incisive canal. The biopsy analysis showed fragments of the incisive artery and nerve, which are responsible for the anterior upper-tooth pulp, the periodontium vascularization and the innervation. From the anastomosis present along with other structures allied with the absence of teeth in the region, there was no detriment to the patient caused by the deflation. Incisive canal deflation is a viable technique in implantology. It can permit ideal prosthetic planning with no detriment to the patient.

  3. Vertical compared with transverse incisions in abdominal surgery

    DEFF Research Database (Denmark)

    Grantcharov, T P; Rosenberg, J

    2001-01-01

    , and late complications (incisional hernia). RESULTS: Eleven randomised controlled trials and seven retrospective studies were identified. The transverse incision offers as good an access to most intra-abdominal structures as a vertical incision. The transverse incision results in significantly less......OBJECTIVE: To reach an evidence-based consensus on the relative merits of vertical and transverse laparotomy incisions. DESIGN: Review of all published randomised controlled trials that compared the postoperative complications after the two main types of abdominal incisions, vertical and transverse....... SETTING: Teaching hospital, Denmark. SUBJECTS: Patients undergoing open abdominal operations. INTERVENTIONS: For some of the variables (burst abdomen and incisional hernia) it was considered adequate to include retrospective studies. Studies were identified through Medline, Cochrane library, Embase...

  4. Influence of Incision Location on Transmitter Loss, Healing, Incision Lengths, Suture Retention, and Growth of Juvenile Chinook Salmon

    Energy Technology Data Exchange (ETDEWEB)

    Panther, Jennifer L.; Brown, Richard S.; Gaulke, Greggory L.; Woodley, Christa M.; Deters, Katherine A.

    2010-05-11

    In this study, conducted by Pacific Northwest National Laboratory for the U.S. Army Corps of Engineers, Portland District, we measured differences in survival and growth, incision openness, transmitter loss, wound healing, and erythema among abdominal incisions on the linea alba, lateral and parallel to the linea alba (muscle-cutting), and following the underlying muscle fibers (muscle-sparing). A total of 936 juvenile Chinook salmon were implanted with both Juvenile Salmon Acoustic Tracking System transmitters (0.43 g dry) and passive integrated transponder tags. Fish were held at 12°C (n = 468) or 20°C (n = 468) and examined once weekly over 98 days. We found survival and growth did not differ among incision groups or between temperature treatment groups. Incisions on the linea alba had less openness than muscle-cutting and muscle-sparing incisions during the first 14 days when fish were held at 12°C or 20°C. Transmitter loss was not different among incision locations by day 28 when fish were held at 12°C or 20°C. However, incisions on the linea alba had greater transmitter loss than muscle-cutting and muscle-sparing incisions by day 98 at 12°C. Results for wound closure and erythema differed among temperature groups. Results from our study will be used to improve fish-tagging procedures for future studies using acoustic or radio transmitters.

  5. Assessment of corneal astigmatism following frown and straight incision forms in sutureless manual small incision cataract surgery

    Directory of Open Access Journals (Sweden)

    Amedo AO

    2016-04-01

    Full Text Available Angela Ofeibea Amedo, Kwadwo Amoah, Nana Yaa Koomson, David Ben Kumah, Eugene Appenteng Osae Department of Optometry and Visual Science, Kwame Nkrumah University of Science and Technology, Kumasi, Ghana Abstract: To investigate which of two tunnel incision forms (frown versus straight in sutureless manual small incision cataract surgery creates more corneal astigmatism. Sixty eyes of 60 patients who had consented to undergo cataract surgery and to partake in this study were followed from baseline through >12-week postoperative period. Values of preoperative and postoperative corneal astigmatism for the 60 eyes, measured with a Bausch and Lomb keratometer, were extracted from the patients’ cataract surgery records. Residual astigmatism was computed as the difference between preoperative and postoperative keratometry readings. Visual acuity was assessed during the preoperative period and at each postoperative visit with a Snellen chart at 6 m. Fifty eyes of 50 patients were successfully followed-up on. Overall, the mean residual astigmatism was 0.75±0.12 diopters. The differences in mean residual astigmatism between the two different incision groups were statistically significant (t [48]=6.33, P<0.05; frown incision group recorded 1.00±0.12 diopters, whereas the straight incision group recorded 0.50±0.12 diopters. No significant difference was observed between male and female groups (t [48]=0.24, P>0.05. Residual corneal astigmatism in the frown incision group was significantly higher than in the straight incision group. Fisher’s exact test did not reveal a significant association between incision forms and visual acuity during the entire postoperative period (P>0.05. Keywords: cataract, residual corneal astigmatism, frown incision, straight incision

  6. Cosmetic effects of skin-crease camouflage incision versus longitudinal incision following carotid endarterectomy.

    Science.gov (United States)

    Kazimierczak, Arkadiusz; Rybicka, Anita; Rynio, Pawel; Gutowski, Piotr; Wiernicki, Ireneusz

    2018-03-01

    Despite the increasing use of carotid angioplasty and stenting (CAS), carotid endarterectomy (CEA) nonetheless remains a more medically beneficial method of treatment for carotid artery stenosis. Therefore, one possibility for progress within this procedure may be to use minimally invasive carotid surgery, especially when the scar is in plain sight: the use of the natural wrinkles (skin crease) as a camouflage of the skin incision provides significant cosmetic improvements. To compare the cosmetic effects of classic and trans-wrinkle CEA. To assess the distance between the carotid artery bifurcation (CAB) and the skin-crease incision whilst attempting CEA. It was a randomized prospective study with two groups: patients undergoing classic surgery (control group; n = 100) and skin-crease trans-wrinkle camouflaged CEA (study group; n = 100). Follow-up was at 2 months and 1 year. The medical results of the treatment were similar in both groups. The cumulative count of strokes and myocardial infarctions was 0.5% within 30 days, and after one year 3.5% (and 5.5% including cases of death). The superiority of the transverse crease being hidden compared to the conventional longitudinal technique was proven in the Patient and Observer Scar Assessment Scale (POSAS) score, respectively 11.4 ±1.0 vs. 14.1 ±3.4 (p = 0.0001) after 2 months and 13.5 ±2.8 vs. 14.1 ±3.4 (p = 0.039) after a year. Trans-wrinkle incision gives better cosmetic results, can be safely performed in most cases, and offers a comfortable approach during CEA.

  7. Laser Resurfacing

    OpenAIRE

    Janik, Joseph P.; Markus, Jodi L.; Al-Dujaili, Zeena; Markus, Ramsey F.

    2007-01-01

    In a society desiring images of beauty and youthfulness, the world of cutaneous surgery offers the gifts of facial rejuvenation for those determined to combat the signs of aging. With the development of novel laser and plasma technology, pigmentary changes, scarring, and wrinkles can be conquered providing smoother, healthier, younger-looking skin. This review highlights five of the most popular resurfacing technologies in practice today including the carbon dioxide (CO2) laser, the erbium:yt...

  8. A skin abscess model for teaching incision and drainage procedures.

    Science.gov (United States)

    Fitch, Michael T; Manthey, David E; McGinnis, Henderson D; Nicks, Bret A; Pariyadath, Manoj

    2008-07-03

    Skin and soft tissue infections are increasingly prevalent clinical problems, and it is important for health care practitioners to be well trained in how to treat skin abscesses. A realistic model of abscess incision and drainage will allow trainees to learn and practice this basic physician procedure. We developed a realistic model of skin abscess formation to demonstrate the technique of incision and drainage for educational purposes. The creation of this model is described in detail in this report. This model has been successfully used to develop and disseminate a multimedia video production for teaching this medical procedure. Clinical faculty and resident physicians find this model to be a realistic method for demonstrating abscess incision and drainage. This manuscript provides a detailed description of our model of abscess incision and drainage for medical education. Clinical educators can incorporate this model into skills labs or demonstrations for teaching this basic procedure.

  9. Morphodynamic Model of Submarine Canyon Incision by Sandblasting

    Science.gov (United States)

    Zhang, L.; Parker, G.; Izumi, N.; Cartigny, M.; Li, T.; Wang, G.

    2017-12-01

    Submarine canyons are carved by turbidity currents under the deep sea. As opposed to subaerial canyons, the relevant processes are not easy to observe directly. Turbidity currents are bottom-hugging sediment gravity flows of that can incise or deposit on the seafloor to create submarine canyons or fans. The triggers of turbidity currents can be storms, edge waves, internal waves, canyon wall sapping, delta failure, breaching and hyperpycnal flows. The formation and evolution mechanisms of submarine canyons are similar to those of subaerial canyons, but have substantial differences. For example, sandblasting, rather than wear due to colliding gravel clasts is more likely to be the mechanism of bedrock incision. Submarine canyons incise downward, and often develop meander bends and levees within the canyon, so defining "fairways". Here we propose a simple model for canyon incision. The starting point of our model is the Macro Roughness Saltation Abrasion Alluviation model of Zhang et al. [2015], designed for bedrock incision by gravel clasts in mixed bedrock-alluvial rivers. We adapt this formulation to consider sandblasting as a means of wear. We use a layer-averaged model for turbidity current dynamics. The current contains a mixture of mud, which helps drive the flow but which does not cause incision, and sand, which is the agent of incision. We show that the model can successfully model channel downcutting, and indeed illustrate the early formation of net incisional cyclic steps, i.e. upstream-migrating undulations on the bed associated with transcritical (in the Froude sense) flow. These steps can be expected to abet the process of incision.

  10. Diathermy versus scalpel incisions for open cholecystectomy comparative study

    International Nuclear Information System (INIS)

    Ali, M.A.; Niazi, W.A.K.

    2014-01-01

    The aim of the study was to make a comparison between skin incisions made with electrocautery versus scalpel in terms of their safety, efficacy and post-operative complications. Design: A randomized controlled study. Setting: The study was conducted in Combined Military Hospital (CMH) Kharian, Pakistan airforce (PAF) Hospital Sargodha. Duration of Study: May 2008 to August 2011. Patients and Methods: Ninety seven patients who underwent open cholecystectomy were randomly divided into two groups on the basis of the use of electrocautery versus steel scalpel for making skin incision and sub-cutaneous tissue dissection. Parameters recorded were, time taken from skin incision to full incising of the peritoneum, length of the wound, amount of blood loss during this step of surgery in each group. Post-operative pain scoring using visual analogue scale was done. Wound complications such as infection, haematoma/seroma and dehiscence were noted too. One month of follow up was recorded in each group. Subsequently a comparison of these findings was done. Results: Incision time (sec/cm/sub 2/) was longer in scalpel group than in diathermy group (p = 0.001), whereas, incision blood loss (ml/cm/sub 2/) was significantly less in diathermy group than in scalpel group (p = 0.03). There was no difference in post-operative pain perception as delineated by visual pain analogue scoring system between the two groups (p = 0.57). Post-operative wound complications and the final healing of wound at 01 month of follow-up were almost similar in both groups. Conclusion: Electrocautery may be used safely without any untoward complication in making skin incision and sub-cutaneous tissue dissection with an advantage of reduced incision time and and less blood loss. (author)

  11. Comparative study of the efficacy of Platelet-rich plasma combined with carboxytherapy vs its use with fractional carbon dioxide laser in atrophic acne scars.

    Science.gov (United States)

    Al Taweel, Abdul-Aziz Ibrahim; Al Refae, Abdul-Aziz Abdul-Salam; Hamed, Ahmed Mohamed; Kamal, Asmaa Mostafa

    2018-04-22

    Acne scars are a major concerning problem to all acne patients affecting their quality of life. Platelet-rich plasma (PRP) and fractional CO 2 laser are innovative treatment modalities for acne scars. Carboxytherapy can also be used to improve scar tissue through the increase in collagen deposition and reorganization, and the improvement in skin texture and tone. The aim of this work was to compare the efficacy, safety, and complications of the intradermal injection of PRP combined with carboxytherapy and PRP combined with fractional CO 2 laser, in the treatment of atrophic acne scars. Forty patients with atrophic acne scars were divided into 2 groups. Group A included 20 patients and was subjected to three fractional CO 2 laser sessions combined with PRP injection. Group B included 20 patients and was subjected to three sessions of carboxytherapy combined with PRP injection. Both fractional CO 2 laser and carboxytherapy combined with PRP showed improvement in acne scars and patients' satisfaction but the improvement with fractional CO 2 laser was significantly better than carboxytherapy but with more side effects. Improvement of acne scars was noted in both treatment modalities with obvious higher and statistically significant results in favor of fractional CO 2 laser but with more side effects. Carboxytherapy is a promising tool in treatment of acne scars with less complication. © 2018 Wiley Periodicals, Inc.

  12. Comparison of the Keratometric Corneal Astigmatic Power after Phacoemulsification: Clear Temporal Corneal Incision versus Superior Scleral Tunnel Incision

    Directory of Open Access Journals (Sweden)

    Yongqi He

    2009-01-01

    Full Text Available Objective. This is prospective randomized control trial to compare the mean keratometric corneal astigmatism diopter power (not surgical induced astigmatism among preop and one-month and three-month postop phacoemulcification of either a clear temporal corneal incision or a superior scleral tunnel Incision, using only keratometric astigmatic power reading to evaluate the difference between the two cataract surgery incisions. Methods. 120 patients (134 eyes underwent phacoemulcification were randomly assigned to two groups: Group A, the clear temporal corneal incision group, and Group B, the superior scleral tunnel incision group. SPSS11.5 Software was used for statistical analysis to compare the postsurgical changes of cornea astigmatism on keratometry. Results. The changes of corneal astigmatic diopter in Groups A and B after 3 month postop from keratometric reading were 1.04 + 0.76 and 0.94 + 0.27, respectively (=.84>.05, which showed no statistic significance difference. Conclusion. The incision through either temporal clear cornea or superior scleral tunnel in phacoemulcification shows no statistic difference in astigmatism change on keratometry 3-month postop.

  13. Effect of laser treatment on first-intention incisional wound healing in ball pythons (Python regius).

    Science.gov (United States)

    Cole, Grayson L; Lux, Cassie N; Schumacher, Juergen P; Seibert, Rachel L; Sadler, Ryan A; Henderson, Andrea L; Odoi, Agricola; Newkirk, Kim M

    2015-10-01

    To evaluate effects of laser treatment on incisional wound healing in ball pythons (Python regius). 6 healthy adult ball pythons. Snakes were sedated, a skin biopsy specimen was collected for histologic examination, and eight 2-cm skin incisions were made in each snake; each incision was closed with staples (day 0). Gross evaluation of all incision sites was performed daily for 30 days, and a wound score was assigned. Four incisions of each snake were treated (5 J/cm(2) and a wavelength of 980 nm on a continuous wave sequence) by use of a class 4 laser once daily for 7 consecutive days; the other 4 incisions were not treated. Two excisional skin biopsy specimens (1 control and 1 treatment) were collected from each snake on days 2, 7, 14, and 30 and evaluated microscopically. Scores were assigned for total inflammation, degree of fibrosis, and collagen maturity. Generalized linear models were used to investigate the effect of treatment on each variable. Wound scores for laser-treated incisions were significantly better than scores for control incisions on day 2 but not at other time points. There were no significant differences in necrosis, fibroplasia, inflammation, granuloma formation, or bacterial contamination between control and treatment groups. Collagen maturity was significantly better for the laser-treated incisions on day 14. Laser treatment resulted in a significant increase in collagen maturity at day 14 but did not otherwise significantly improve healing of skin incisions.

  14. Laser Resurfacing Pearls

    OpenAIRE

    Shah, Sonia; Alam, Murad

    2012-01-01

    Ablative skin resurfacing using the carbon dioxide laser was long considered the gold standard for treatment of photoaging, acne scars, and rhytids. However, conventional full-face carbon dioxide resurfacing is associated with significant risk of side effects and a prolonged postoperative recovery period. Fractional resurfacing has recently revolutionized laser surgery by offering close to comparable results with minimal side effects and a more rapid recovery. Although fractional devices have...

  15. Lateral Erosion Encourages Vertical Incision in a Bimodal Alluvial River

    Science.gov (United States)

    Gran, K. B.

    2015-12-01

    Sand can have a strong impact on gravel transport, increasing gravel transport rates by orders of magnitude as sand content increases. Recent experimental work by others indicates that adding sand to an armored bed can even cause armor to break-up and mobilize. These two elements together help explain observations from a bimodal sand and gravel-bedded river, where lateral migration into sand-rich alluvium breaks up the armor layer, encouraging further incision into the bed. Detailed bedload measurements were coupled with surface and subsurface grain size analyses and cross-sectional surveys in a seasonally-incised channel carved into the upper alluvial fan of the Pasig-Potrero River at Mount Pinatubo, Philippines. Pinatubo erupted in 1991, filling valleys draining the flanks of the volcano with primarily sand-sized pyroclastic flow debris. Twenty years after the eruption, sand-rich sediment inputs are strongly seasonal, with most sediment input to the channel during the rainy season. During the dry season, flow condenses from a wide braided planform to a single-thread channel in most of the upper basin, extending several km onto the alluvial fan. This change in planform creates similar unit discharge ranges in summer and winter. Lower sediment loads in the dry season drive vertical incision until the bed is sufficiently armored. Incision proceeds downstream in a wave, with increasing sediment transport rates and decreasing grain size with distance downstream, eventually reaching a gravel-sand transition and return to a braided planform. Incision depths in the gravel-bedded section exceeded 3 meters in parts of a 4 km-long study reach, a depth too great to be explained by predictions from simple winnowing during incision. Instead, lateral migration into sand-rich alluvium provides sufficient fine sediment to break up the armor surface, allowing incision to start anew and increasing the total depth of the seasonally-incised valley. Lateral migration is recorded in a

  16. Effects of two different incision phacoemulsification on corneal astigmatism

    Directory of Open Access Journals (Sweden)

    Lu Huo

    2014-12-01

    Full Text Available AIM:To compare the effect of different incision in corneal astigmatism after phacoemulsification. METHODS: Totally 88 cases(122 eyeswith pure cataract were randomly divided into two groups. Forty cases(60 eyeswere clarity corneal incision in group A, and 48 cases(62 eyeswere sclera tunnel incision in group B. Mean corneal astigmatism, surgically induced astigmatism(SIA, uncorrected visual acuity(UCVAand best correct vision acuity(BCVAwere observed in pre- and post-operation at 1d; 1wk; 1mo.RESULTS: The mean astigmatism had statistically significant difference between two groups at 1d; 1wk; 1mo after operation(PPP>0.05. UCVA≥0.5 and BCVA≥0.8 had statistically significant difference at 1d; 1wk(PP>0.05.CONCLUSION: Phacoemulsification with scleral tunnel incision remove combined intraocular lens(IOLimplantation has small changes to corneal astigmatism. By selecting personalized corneal incision according to the corneal topography might be more beneficial.

  17. Clinical and Histological Evaluations of Enlarged Facial Skin Pores After Low Energy Level Treatments With Fractional Carbon Dioxide Laser in Korean Patients.

    Science.gov (United States)

    Kwon, Hyuck Hoon; Choi, Sun Chul; Lee, Won-Yong; Jung, Jae Yoon; Park, Gyeong-Hun

    2018-03-01

    Enlarged facial pores can be an early manifestation of skin aging and they are a common aesthetic concern for Asians. However, studies of improving the appearance of enlarged pores have been limited. The authors aimed to study the application of CO2 fractional laser treatment in patients with enlarged facial pores. A total of 32 patients with dilated facial pores completed 3 consecutive sessions of low energy level treatments with a fractional CO2 laser at 4-week intervals. Image analysis was performed to calculate the number of enlarged pores before each treatment session and 12 weeks after the final treatment. After application of laser treatments, there was a significant decrease in the number of enlarged pores. The mean number of enlarged pores was decreased by 28.8% after the second session and by 54.5% at post-treatment evaluation. Post-treatment side effects were mild and transitory. Histological and immunohistochemical analyses demonstrated clear increases in the number of collagen fibers and the expression of transforming growth factor-β1. The short-term results showed that treatment with low energy level CO2 fractional laser therapy could be a safe and effective option for patients with Fitzpatrick skin Types III and IV who are concerned with enlarged pores.

  18. Refractive lenticule extraction (ReLEx through a small incision (SMILE for correction of myopia and myopic astigmatism: current perspectives

    Directory of Open Access Journals (Sweden)

    Ağca A

    2016-10-01

    Full Text Available Alper Ağca,1 Ahmet Demirok,2 Yusuf Yıldırım,1 Ali Demircan,1 Dilek Yaşa,1 Ceren Yeşilkaya,1 İrfan Perente,1 Muhittin Taşkapılı1 1Beyoğlu Eye Research and Training Hospital, 2Department of Ophthalmology, Istanbul Medeniyet University, Istanbul, Turkey Abstract: Small-incision lenticule extraction (SMILE is an alternative to laser-assisted in situ keratomileusis (LASIK and photorefractive keratectomy (PRK for the correction of myopia and myopic astigmatism. SMILE can be performed for the treatment of myopia ≤-12 D and astigmatism ≤5 D. The technology is currently only available in the VisuMax femtosecond laser platform. It offers several advantages over LASIK and PRK; however, hyperopia treatment, topography-guided treatment, and cyclotorsion control are not available in the current platform. The working principles, potential advantages, and disadvantages are discussed in this review. Keywords: SMILE, small-incision lenticule extraction, femtosecond laser, laser in situ keratomileusis, corneal biomechanics

  19. Modification of the Nuss Procedure: The Single-incision Technique

    Directory of Open Access Journals (Sweden)

    Tetsushi Aizawa, MD

    2014-11-01

    Full Text Available Summary: The Nuss procedure is a prevalent minimally invasive surgery for pectus excavatum. Although the Nuss procedure has the advantage of leaving less obtrusive scars, the standard technique requires at least 3 skin incisions to insert several instruments. We experienced 7 cases of the modified Nuss procedure using a single incision during a 7-year period. To facilitate passing of the bar, a traction guide was created according to our unique method. There was no need for a bar stabilizer, and no severe intraoperative complications occurred. All patients exhibited satisfactory short-term results; however, 1 patient suffered from bar rotation and required repeat surgery for fixation. Two patients underwent bar removal via the same single incision without any difficulties.

  20. Minimizing surgical skin incision scars with a latex surgical glove.

    Science.gov (United States)

    Han, So-Eun; Ryoo, Suk-Tae; Lim, So Young; Pyon, Jai-Kyung; Bang, Sa-Ik; Oh, Kap-Sung; Mun, Goo-Hyun

    2013-04-01

    The current trend in minimally invasive surgery is to make a small surgical incision. However, the excessive tensile stress applied by the retractors to the skin surrounding the incision often results in a long wound healing time and extensive scarring. To minimize these types of wound problems, the authors evaluated a simple and cost-effective method to minimize surgical incision scars based on the use of a latex surgical glove. The tunnel-shaped part of a powder-free latex surgical glove was applied to the incision and the dissection plane. It was fixed to the full layer of the dissection plane with sutures. The glove on the skin surface then was sealed with Ioban (3 M Health Care, St. Paul, MN, USA) to prevent movement. The operation proceeded as usual, with the retractor running through the tunnel of the latex glove. It was possible to complete the operation without any disturbance of the visual field by the surgical glove, and the glove was neither torn nor separated by the retractors. The retractors caused traction and friction during the operation, but the extent of damage to the postoperative skin incision margin was remarkably less than when the operation was performed without a glove. This simple and cost-effective method is based on the use of a latex surgical glove to protect the surgical skin incision site and improve the appearance of the postoperative scar. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  1. Simulation of channel sandstone architecture in an incised valley

    Energy Technology Data Exchange (ETDEWEB)

    Frykman, P.; Johannessen, P.; Andsbjerg, J.

    1998-12-31

    The present report describes a geostatistical modelling study that is aimed at reflecting the architecture of the channel sandstones in an incised valley fill. The example used for this study is a part of the Middle Jurassic sandy succession of the Bryne Formation in the Danish central Graben. The succession consists mainly of fluvial sediments in the lower part, overlain by tidal influenced sediments, which again is overlain by shallow marine sediments. The modelling study has been performed on a sequence of incised valley sediments in the upper part of the Bryne Formation overlying fluvial sediments. (au) EFP-96. 19 refs.

  2. Better outcome from arthroscopic partial meniscectomy than skin incisions only?

    DEFF Research Database (Denmark)

    Roos, Ewa M; Hare, Kristoffer Borbjerg; Nielsen, Sabrina Mai

    2018-01-01

    . In total, nine participants experienced 11 adverse events; six in the surgery group and three in the skin-incisions-only group. CONCLUSION: We found greater improvement from arthroscopic partial meniscectomy compared with skin incisions only at 2 years, with the statistical uncertainty of the between......-group difference including what could be considered clinically relevant. Because of the study being underpowered, nearly half in the sham group being non-blinded and one-third crossing over to surgery, the results cannot be generalised to the greater patient population. TRIAL REGISTRATION NUMBER: NCT01264991....

  3. Detection of salts in soil using transversely excited atmospheric (TEA) carbon dioxide (CO2) laser-induced breakdown spectroscopy (LIBS) by the aid of a metal mesh

    Science.gov (United States)

    Idris, N.; Ramli, M.; Khumaeni, A.; Kurihara, K.

    2018-04-01

    In this work, a nickel metal mesh was used to allow a direct detection of salt in soil sample by LIBS utilizing unique characteristics of a TEA CO2. The metal mesh is placed in the front of the soil sample to prevent the soil sample from blowing off upon focusing the high pulsed laser beam irradiation. LIBS apparatus used in this work is a TEA CO2 laser operated at wavelength of 10.6 μm with pulse energy and duration of 3J and 200 ns, respectively. The laser beam was focused using a ZnSe lens (f = 200 mm) onto soil sample after passing through the metal mesh. The emission spectrum from the induced plasma was detected using an optical multichannel analyzer (OMA) system consisting of a 0.32-m-focal length spectrograph with a grating of 1200 graves/mm and a 1024-channel photodiode detector array with a micro-channel plate intensifier. The soil sample used is a standard soil and ordinary soil containing several salts such as Ca, Mg at high concentration. The LIBS experiment was carried out at high pressure surrounding gas of 1 atmosphere. It was observed that by the aid of the metal mesh, strong breakdown gas plasma can be produced just after TEA CO2 laser irradiation on soil sample without significant sample blowing off. It was found that emission lines from salts, Ca (Ca II 393. 3 nm, Ca II 396.3 nm, Ca I 422.5 nm), and also other salts including Mg and Na can clearly be detected with strong emission intensity and narrow spectral width. This result implies that a TEA CO2 LIBS assisted by the metal mesh (metal mesh method) can be used for direct analysis several salts such as Ca, Mg, and Na in soil sample.

  4. Meta-analysis of the effectiveness of surgical scalpel or diathermy in making abdominal skin incisions.

    LENUS (Irish Health Repository)

    Ahmad, Nasir Zaheer

    2012-02-01

    BACKGROUND: Surgical scalpels are traditionally used to make skin incisions. Diathermy incisions on contrary are less popular among the surgeons. The aim of this meta-analysis was to compare the effectiveness of both techniques and address the common fallacies about diathermy incisions. METHODS: A literature search of MEDLINE and Cochrane databases was done, using the keywords diathermy, cold scalpel, and incisions. Eleven clinical trials comparing both methods of making skin incisions were selected for meta-analysis. The end points compared included postoperative wound infection, pain in first 24 hours after surgery, time taken to complete the incisions, and incision-related blood loss. RESULTS: Postoperative wound infection rate was comparable in both techniques (P = 0.147, odds ratio = 1.257 and 95% CI = 0.923-1.711). Postoperative pain was significantly less with diathermy incisions in first 24 hours (P = 0.031, weighted mean difference = 0.852 and 95% CI = 0.076-1.628). Similarly, the time taken to complete the incision and incision-related blood loss was significantly less with diathermy incisions (95% CI = 0.245-0.502 and 0.548-1.020, respectively). CONCLUSION: Diathermy incisions are equally prone to get wound infection, as do the incisions made with scalpel. Furthermore, lower incidence of early postoperative pain, swiftness of the technique, and a reduced blood loss are the encouraging facts supporting routine use of diathermy for abdominal skin incisions after taking careful precautions.

  5. "Meniscus Sign" to Identify the Lenticule Edge in Small-Incision Lenticule Extraction.

    Science.gov (United States)

    Titiyal, Jeewan S; Kaur, Manpreet; Brar, Anand S; Falera, Ruchita

    2018-06-01

    To describe our technique of lenticule edge identification in small-incision lenticule extraction using the "meniscus sign" to prevent lenticule misdissection. Femtosecond laser application for small-incision lenticule extraction was performed. A "double ring" was visible, signifying the edge of the cap cut (outer ring) and lenticule cut (inner ring). The anterior and posterior lamellar planes were delineated in 2 different directions. During creation of the posterior lamellar channel, the lenticule edge was slightly pushed away from the surgeon to create a gap between the inner ring (diameter of the lenticule cut) and the lenticule edge. The lenticule edge assumed a frilled wavy appearance, and the meniscus sign was observed as a gap between the lenticule edge and the inner ring. The meniscus-shaped gap served as a landmark to identify the lenticule edge, and the relationship between the frilled lenticule edge and surgical instruments further acted as a guide to identify the correct plane of dissection. This technique was successfully undertaken in 50 eyes of 25 patients. The meniscus sign was observed in all cases, and no case had cap lenticular adhesions. The meniscus sign helps to identify the lenticule edge and correct dissection planes and provides a visual landmark during the entire surgical procedure.

  6. Combination of platelet rich plasma in fractional carbon dioxide laser treatment increased clinical efficacy of for acne scar by enhancement of collagen production and modulation of laser-induced inflammation.

    Science.gov (United States)

    Min, Seonguk; Yoon, Ji Young; Park, Seon Yong; Moon, Jungyoon; Kwon, Hyuck Hoon; Suh, Dae Hun

    2018-04-01

    Platelet-rich plasma (PRP) which contains large amounts of growth factors has been tried to enhance therapeutic efficacy of laser treatment for acne scar with unknown underlying mechanism. The present study was conducted to investigate the molecular mechanism of increased clinical efficacy of PRP when combined with fractional laser treatment for treating acne scars. Subjects with mild to moderate acne scars were treated with two sessions of fractional CO 2 laser therapy given with and without co-administration of PRP. Skin biopsy specimens were obtained at baseline, 1, 3, 7, and 28 days for investigation of molecular profiles associated with skin changes produced by laser plus PRP treatment. The PRP treatment increased clinical efficacy with decreased severity of adverse effects such as erythema, swelling and oozing. Productions of TGFβ1 and TGFβ3 proteins were more highly elevated on the PRP-treated side of the face compared to the control side at day 28. Furthermore, PRP-treated side showed significant increase of c-myc, TIMP, and HGF expression. Experimental fibroblast culture model was also used. PRP administration after laser irradiation increased expressions of p-Akt, TGFβ1, TGFβ3, β-catenin, collagen 1, and collagen 3 in both dose-dependent and time dependent manners in fibroblast. Moreover, we acquired clinical and histological data through randomized control clinical trial. Taken together with human study results combined with the data from cell experiments we suggest that PRP treatment increased fibrogenetic molecules induced by fractional CO 2 laser, which have association with clinical effect. Lasers Surg. Med. 50:302-310, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  7. Minimal incision surgery in strabismus: Modified fornix-based approach.

    Science.gov (United States)

    Pérez-Flores, I

    2016-07-01

    To evaluate the modified fornix-based technique as an approach for minimal incision surgery in strabismus. The medical records of all consecutive patients that underwent strabismus surgery with fornix-based conjunctival incision between 2007 and 2012 were retrospectively reviewed. As a primary variable, an analysis was made of the wound size depending on the number of stitches. A descriptive study was performed on the variables related to patients and to the type of strabismus and surgery. Out of 153patients identified, 138 with 294 surgeries were included. In 200 (68%) interventions, the incision was sutured with one stitch, in 77 (26.2%) with 2, in 13 (4.4%) with 3, and in 4 (1.4%) with 4, with the mean number of stitches being 1.39±0.64. The mean age of the patients was 39years (2-80), and 36 (26.1%) had previous strabismus surgery, with topical anaesthesia being used in 35 (25.4%) cases. At 3months after surgery deviation was ≤10DP in 114 (82.6%) patients. There were no wound-related complications. The modified fornix-based technique is an effective and safe approach for minimal incision surgery in strabismus, in patients at all ages, with previous history of strabismus surgery and with topical anaesthesia. Copyright © 2015 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

  8. Phenomenon of mucous retention in the incisive canal.

    Science.gov (United States)

    Keith, D A

    1979-11-01

    Mucous glands are rarely found in the anterior palate but may be observed in the incisive canal. A case history is presented of a lesion that resembled a nasopalatine cyst both clinically and radiographically but which was in fact an intra-bony extravasation phenomenon.

  9. Heterotopic ossification in abdominal incision : a case report

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Yoon Sik; Nam, Kung Sook; Hwang, Im Kyung; Kim, Heung Chul [College of Medicine, Hallym Univ., Chuncheon (Korea, Republic of)

    2001-08-01

    Heterotopic ossification in abdominal incision is a rare post-surgical sequala and a subtype of myositis ossificans traumatica. Recognition of this rare condition is important because it may be misinterpreted as a retained foreign body or incisional neoplastic recurrence. We report a case involving a 59-year-old man who presented with a palpable epigastric mass and pronounced fatigability.

  10. Tubularized incised plate technique for recurrent hypospadias: a ...

    African Journals Online (AJOL)

    management of recurrent hypospadias. Summary background ... The potential advantages of tubularized incised plate .... after a mean duration of 4.9 ± 3.1 years from the previous repair (Table 2). .... erection and the risk of infection, especially in patients older than 15 .... However, previous surgery often limits the availability ...

  11. Ultrasonic diagnosis and transurethral incision of ureterocele with hydronephrosis

    DEFF Research Database (Denmark)

    Waaddegaard, P; Miskowiak, J; Stage, P

    1991-01-01

    In a 65-year-old woman with right-sided loin pain, ultrasonography revealed a grossly dilated and obstructed right pyelogram due to a 50-mm ureterocele. After transurethral lateral incision of the ureterocele, there was complete recovery without vesicoureteric reflux. Ultrasonography is advantage...

  12. Single-incision laparoscopic cholecystectomy with needle graspers.

    Science.gov (United States)

    Sumiyoshi, Kinjiro; Sato, Norihiro; Akagawa, Shin; Hirano, Tatsuya; Koikawa, Kazuhiro; Horioka, Kohei; Ozono, Keigo; Fujiwara, Kenji; Tanaka, Masao; Sada, Masayuki

    2012-01-01

    Single-incision laparoscopic cholecystectomy (SILC) is a promising alternative to standard multi-incision laparoscopic cholecystectomy (LC). However, generalization of SILC is still hampered by technical difficulties mainly associated with the lack of trocars used for retraction of the gallbladder. We therefore developed a modified method of SILC with the use of needle graspers (SILC-N) for optimal retraction and exposure. In addition to two trocars inserted through a single transumbilical incision, two needle ports were placed on the right subcostal and lateral abdominal wall, through which needle graspers were used for retraction of the gallbladder. Since December, 2009, 12 patients with symptomatic cholelithiasis were treated by SILC-N. SILC-N was successfully performed in all but one patient requiring a conversion to the 4-port LC with a mean operative time of 71.5 (48-107) minutes. None of the patients experienced intraoperative or postoperative complications. The transumbilical incision and pinholes for needle graspers were almost invisible on discharge. Our preliminary results suggest that SILC-N is a simple, safe and feasible technique of cholecystectomy offering similar postoperative recovery and better cosmetic outcome as compared to conventional LC.

  13. Single-incision laparoscopic surgery for pyloric stenosis.

    Science.gov (United States)

    Kozlov, Yury; Novogilov, Vladimir; Podkamenev, Alexey; Rasputin, Andrey; Weber, Irina; Solovjev, Alexey; Yurkov, Pavel

    2012-04-01

    Laparoscopy is the most common procedure for correction of congenital pyloric stenosis. The standard laparoscopic approach is based on the three-port technique. In contrast to the standard laparoscopic technique, the single-incision laparoscopic surgery (SILS) requires only one incision. We report on our experience with this surgical approach. Between September 2009 and August 2010 a total of 24 children underwent a laparoscopic pyloromyotomy, 12 in SILS technique. The single incision was carried through the center of the umbilicus. The working instruments were introduced in a two-dimensional direction into the peritoneal cavity via the same umbilical incision. The two groups were compared for patients' demographics, operative report and early postoperative outcomes. All SILS procedures were performed successfully with no conversion rate. There were no differences in the preoperative parameters between the two groups regarding age before surgery and body weight at operation. Operative time and time of full enteral intake was similar to comparable procedures with usage of a standard laparoscopic approach. There were no operative or postoperative complications. The early experience described in this study confirms that SILS can be applied for treatment of pyloric stenosis with outcomes similar to the standard laparoscopic surgery.

  14. Cost assessment of instruments for single-incision laparoscopic cholecystectomy

    DEFF Research Database (Denmark)

    Henriksen, Nadia A; Al-Tayar, Haytham; Rosenberg, Jacob

    2012-01-01

    Specially designed surgical instruments have been developed for single-incision laparoscopic surgery, but high instrument costs may impede the implementation of these procedures. The aim of this study was to compare the cost of operative implements used for elective cholecystectomy performed...

  15. [External periareolar incision for subdermal mastectomy in men with gynecomastia].

    Science.gov (United States)

    Montiel-Jarquín, Alvaro; Reyes-Páramo, Pedro; Ramos-Alvarez, Gloria; López-Colombo, Aurelio; Tinajero-Esquivel, Magdalena; Ruiz-León, Betzabé

    2007-01-01

    Gynecomastia describes a benign increase of the mammary gland in men. When medical treatment fails, symptoms and psychological alterations persist. Subdermal mastectomy is the definitive treatment and can be achieved by different incisions, each with potential complications. We undertook this study to present clinical characteristics of 11 patients with gynecomastia and the results obtained with subdermal mastectomy by means of external periareolar incision. A descriptive cohort study in male patients with gynecomastia was carried out in a third-level medical care hospital. Patients were treated with subdermal mastectomy by means of external periareolar incision. There were 11 male patients with an average age of 19 years (range: 11-60 years), 3 patients (27.2%) with bilateral gynecomastia and 8 patients (72.7%) with unilateral gynecomastia. Average time of evolution was 22 months (range: 16-48 months), 9 patients (81.8%) reported pain, 11 patients (100%) reported psychological alterations with cutaneous alteration, 11 patients (100%) had normal secondary sexual characteristics, 1 patient (9%) had supernumerary nipple development, and 11 patients (100%) had well-defined lesions. According to Simon's classification: seven patients (63.6%) were classified as grade 1, three patients (27.2%) as grade 2 and one patient (9.09%) as grade 3. Each patient had a subdermal mastectomy with external periareolar incision, 11 patients (100%) had a histopathological report of gynecomastia; 1 patient (9.09%) displayed keloid healing and none displayed complications inherent to the surgical procedure. Mastectomy by means of external periareolar incision is useful in the treatment of gynecomastia.

  16. The width of the incisive canal and labial alveolar bone of the incisive canal: an assessment on CT images

    International Nuclear Information System (INIS)

    Roh, Yang Gyun; Jang, Hyun Seon; Kim, Byung Ock; Kim, Jin Soo

    2006-01-01

    To assess the width of the labial alveolar bone of the incisive canal and the width of the incisive canal on spiral computed tomographic images of the anterior portion of the maxilla. Study materials included 38 CT scans taken for preoperative planning of implant placement. Axial cross-sectioned image entirely showing the incisive canal at an orifice to the oral cavity, middle portion, and an orifice to the nasal cavity and the diameter of the incisive canal at the middle portion were determined by two specialist using Digora for Windows 2.1. The statistical analyses were carried out using SPSS 12.0.1. When the maxillary central incisors remained, the mean labial alveolar bone width were 6.81±1.41 mm, 6.46±1.33 mm, and 7.91±1.33 mm. When the maxillary central incisors were missed the mean width were 5.42±2.20 mm, 6.23±2.29 mm, and 7.89±2.13 mm. The labial alveolar bone width at middle portion and an orifice to the nasal cavity were of no statistical significant difference according to presence of the maxillary central incisors (P>0.05). The width between oral cavity and nasal cavity, middle portion and to masal cavity revealed statistically significant difference (P<0.05)

  17. Incisional hernia after upper abdominal surgery: A randomised controlled trial of midline versus transverse incision

    NARCIS (Netherlands)

    J.A. Halm (Jens); H. Lip (Harm); P.I.M. Schmitz (Paul); J. Jeekel (Hans)

    2009-01-01

    textabstractObjectives: To determine whether a transverse incision is an alternative to a midline incision in terms of incisional hernia incidence, surgical site infection, postoperative pain, hospital stay and cosmetics in cholecystectomy. Summary background data: Incisional hernias after midline

  18. Mars Atmospheric Escape Recorded by H, C and O Isotope Ratios in Carbon Dioxide and Water Measured by the Sam Tunable Laser Spectrometer on the Curiosity Rover

    Science.gov (United States)

    Webster, C. R.; Mahaffy, P. R.; Leshin, L. A.; Atreya, S. K.; Flesch, G. J.; Stern, J.; Christensen, L. E.; Vasavada, A. R.; Owen, T.; Niles, P. B.; hide

    2013-01-01

    Stable isotope ratios in C, H, N, O and S are powerful indicators of a wide variety of planetary geophysical processes that can identify origin, transport, temperature history, radiation exposure, atmospheric escape, environmental habitability and biological activity [2]. For Mars, measurements to date have indicated enrichment in all the heavier isotopes consistent with atmospheric escape processes, but with uncertainty too high to tie the results with the more precise isotopic ratios achieved from SNC meteoritic analyses. We will present results to date of H, C and O isotope ratios in CO2 and H2O made to high precision (few per mil) using the Tunable Laser Spectrometer (TLS) that is part of the Sample Analysis at Mars (SAM) instrument suite on MSL s Curiosity Rover.

  19. Ablative fractional carbon dioxide laser combined with intense pulsed light for the treatment of photoaging skin in Chinese population: A split-face study.

    Science.gov (United States)

    Mei, Xue-Ling; Wang, Li

    2018-01-01

    Intense pulsed light (IPL) is effective for the treatment of lentigines, telangiectasia, and generalized erythema, but is less effective in the removal of skin wrinkles. Fractional laser is effective on skin wrinkles and textural irregularities, but can induce postinflammatory hyperpigmentation (PIH), especially in Asians. This study evaluated the safety and efficacy of ablative fractional laser (AFL) in combination with IPL in the treatment of photoaging skin in Asians.This study included 28 Chinese women with Fitzpatrick skin type III and IV. The side of the face to be treated with IPL alone (3 times) or AFL in combination with IPL (2 IPL treatments and 1 AFL treatment) was randomly selected. Skin conditions including hydration, transepidermal water loss, elasticity, spots, ultraviolet spots, brown spots, wrinkle, texture, pore size and red areas, as well as adverse effects were evaluated before the treatment and at 30 days after the treatment.Compared with IPL treatment alone, AFL in combination with IPL significantly increased elasticity, decreased pore size, reduced skin wrinkles, and improved skin texture (P = .004, P = .039, P = .015, and P = .035, respectively). Both treatment protocols produced similar effects in relation to the improvement of photoaging-induced pigmentation. The combined therapy did not impair epidermal barrier function. No postoperative infection, hypopigmentation, or scarring occurred after IPL and AFL treatments. PIH occurred at 1 month after AFL treatment and disappeared at 30 days after completion of the combined therapy.AFL in combination with IPL is safe and effective for photoaging skin in Asians. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  20. What can we learn from fluvial incision in high mountains?

    Science.gov (United States)

    Fuchs, Margret; Gloaguen, Richard; Krbetschek, Matthias

    2013-04-01

    High and actively deforming mountain ranges attract the attention of geoscientists as they provide natural laboratories of fast evolving process-response systems. Tectonic compressional settings, often linked to perpendicular extension, control the topographic growth and hence, erosion, transport pathways and sedimentation. High altitude differences within short horizontal distances promote material re-organisation and high rates of surface processes. Furthermore, high mountains constitute orographic barriers that affect atmospheric circulations as well as host different climate regimes similar to those of widely separated latitudinal belts. Both cause a high sensitivity of surface processes to changes in climatic conditions. However, feedbacks between climatic and tectonic forcing are complex. Additionally, the dominance of one or the other varies in space and also over time, inheriting various traces of the paleo-morphodynamic conditions to the subsequent process regimes. To unravel the forces driving the evolution of relief in active mountains, numerous studies employ the drainage network of the corresponding mountains as a proxy of landscape evolution. Especially the rates of river incision provide a powerful tool to characterize the surface response and infer causes behind it. Several parameters of river incision are available to describe the fluvial incision at individual sites (e.g. terrace incision rates), along the river course (e.g. longitudinal river profiles, Hack index) and in its perpendicular dimension (e.g. valley cross sections, valley shape ratios). But they require careful interpretation. They are sensitive to both, climatic and tectonic forcing. Therefore, the synopsis of such indices for fluvial incision is essential to evaluate the role of climatic versus tectonic forcing. Here, we use the Panj river system, the major river draining the Pamir mountains of Central Asia, as an example. The Panj experiences high altitude changes of more than 4000

  1. Surgical peripheral iridectomy via a clear-cornea phacoemulsification incision for pupillary block following cataract surgery in acute angle closure.

    Science.gov (United States)

    Fang, Aiwu; Wang, Peijuan; He, Rui; Qu, Jia

    2018-05-18

    To describe a technique of surgical peripheral iridectomy via a clear-cornea tunnel incision to prevent or treat pupillary block following phacoemulsification. Description of technique and retrospective description results in 20 eyes of 20 patients with acute angle closure with coexisting visually significant cataract undergoing phacoemulsification considered at risk of postoperative papillary block as well as two pseudo-phakic eyes with acute postoperative pupillary-block. Following phacoemulsification and insertion of an intraocular lens, a needle with a bent tip was inserted behind the iris through the corneal tunnel incision. A blunt iris repositor was introduced through the paracentesis and placed above the iris to exert posterior pressure and create a puncture. The size of the puncture was enlarged using scissors. For postoperative pupillary block the same technique was carried out through the existing incisions created for phacoemulsification. Peripheral iridectomy was successfully created in all 22 eyes. At a mean follow-up of 18.77 ± 9.72 months, none of the iridectomies closed or required enlargement. Two eyes had mild intraoperative bleeding and one eye a small Descemet's detachment that did not require intervention. No clinically significant complications were observed. Visual acuity and IOP improved or was maintained in all patients. The incidence of pupillary block in our hospital was 0.09% overall, 0.6% in diabetics and 3.5% in those with diabetic retinopathy. This technique of peripheral iridectomy via the cornea tunnel incision can be safely used during phacoemulsification in eyes at high risk of pupillary block or in the treatment of acute postoperative pupillary-block after cataract surgery. The technique is likely to be especially useful in brown iris, or if a laser is not available.

  2. Channel incision and suspended sediment delivery at Caspar Creek, Mendocino County, California

    Science.gov (United States)

    Nicholas J. Dewey; Thomas E. Lisle; Leslie M. Reid

    2003-01-01

    Tributary and headwater valleys in the Caspar Creek watershed,in coastal Mendocino County, California,show signs of incision along much of their lengths.An episode of incision followed initial-entry logging which took place between 1860 and 1906. Another episode of incision cut into skid-trails created for second-entry logging in the 1970's.

  3. Gully incision rates on the bedrock of a large dip-slope landslide revealed by multi-period LiDAR DEMs

    Science.gov (United States)

    Chan, Y. C.; Hsieh, Y. C.

    2017-12-01

    Recent advances in airborne laser scanning (ALS) technology have provided a great opportunity for characterizing surface erosion through developing improved methods in multi-period DEM differencing and geomorphometry. This study uses three periods of ALS digital elevation model (DEM) data to analyze the short-term erosional features of the Tsaoling landslide triggered by the 1999 Chi-Chi earthquake in Taiwan. Two methods for calculating the bedrock incision rate, the equal-interval cross section selection method and the continuous swath profiles selection method, were used in the study after nearly ten years of gully incision following the earthquake-triggered dip-slope landslide. Multi-temporal gully incision rates were obtained using the continuous swath profiles selection method, which is considered a practical and convenient approach in terrain change studies. After error estimation and comparison of the multi-period ALS DEMs, the terrain change in different periods can be directly calculated, reducing time-consuming fieldwork such as installation of erosion pins and measurement of topographic cross sections on site. In this study, the gully bedrock incision rates ranged between 0.23 and 3.98 m/year, remarkably higher than the typical results from the previous studies. By comparing the DEM data, aerial photos, and precipitation records of this area, the effects of erosion could be observed from the retreat of the Chunqiu Cliff outline during August 2011 to September 2012. It was inferred that the change in the topographic elevation during 2011-2012 was mainly due to the torrential rain brought by Typhoon Soula, which occurred on 30 July 2012. The local gully incision rate in the lower part of the landslide surface was remarkably faster than that of the other regions, suggesting that the fast incision of the toe area possibly contributes to the occurrence of repeated landslides in the Tsaoling area.

  4. Incisive papilla and positions of maxillary anterior teeth among ...

    African Journals Online (AJOL)

    Results: One hundred and twelve maxillary casts generated from participants aged 18-35 years (mean age 22.39±2.00 years), with well aligned arches were studied. The maxillary central incisor exhibited a mean of 14.93±1.52mm from the posterior limit of the incisive papilla while the inter-canine line scored a mean of ...

  5. Manual small incision extracapsular cataract surgery in Australia.

    Science.gov (United States)

    van Zyl, Lourens; Kahawita, Shyalle; Goggin, Michael

    2014-11-01

    Examination of the results and describing the technique of manual small incision extracapsular cataract extraction on patients with advanced cataracts in urban Australia. A descriptive case series. Thirty-eight patients at three public hospitals, one tertiary and two secondary ophthalmic units in urban Australia. Forty eyes with dense mature cataracts with hand movement vision or worse underwent a planned manual small incision extracapsular cataract extraction instead of traditional phaco-emulsification. Postoperative visual aquity, surgically induced astigmatism and complications. Seventy-eight per cent of patients had an uncorrected visual acuity of 6/12 or better on the first postoperative day. Eighty-three per cent of patients had a distance corrected visual acuity of 6/9 or better 3 months postoperatively. One case was complicated by a posterior capsule rupture. No cases of endophthalmitis were reported. The summated vector mean of the surgically induced astigmatism was 0.089D at 93°. Manual small incision extracapsular cataract extraction is an efficacious cataract surgery technique with good visual outcome and is a safe alternative to phaco-emulsification in suitable cases in a first-world setting. © 2014 Royal Australian and New Zealand College of Ophthalmologists.

  6. Single incision thoracoscopic sympathectomy for palmar and axillary hyperhidrosis

    Directory of Open Access Journals (Sweden)

    Aram Baram

    2014-02-01

    Full Text Available Background: Primary hyperhidrosis is characterized by excessive sweating beyond physiological needs. It is a common disease (incidence 2.8% that causes intense discomfort for patients. In the last decade, advantages of Single-Incision Thoracoscopic Sympathectomy have become clear, particularly in decreasing morbidity of sympathectomy. Patients and methods: From January 2010 to December 2012, 39 patients (29 females and 10 males with primary palmar or axillary hyperhidrosis were treated by thoracoscopic sympathectomy. The age ranged from 18 to 40 years with a mean of 26.28 years. We used single incision thoracoscopic electrocoagulation through 10 mm incision for thoracic sympathetic chain (T2–T4. Results: The mean follow-up was 23.6 ± 14.2 months (range = 4–24 months. A total of 97.42% of patients were satisfied with the results. A total of 72.5% of patients had cure, one patient (2.5% and another patient (2.5% presented with recurrent axillary hyperhidrosis. The morbidity was 10.2% with no mortality. Percentage of compensatory sweating and gustatory sweating were 5.1% (p = .353 and 2.5% (p = .552, respectively. The result of sympathectomy in patients with both palmar and axillary hyperhidrosis was significantly better (17, 43.58% compared to palmar type (14, 35.89% or axillary type (7, 17.94%. Conclusion: Thoracoscopic sympathectomy is a simple, safe, and cost-effective therapy with good results and low complications.

  7. The use of laser CO2 in salivary gland diseases

    Science.gov (United States)

    Ciolfi, C.; Rocchetti, F.; Fioravanti, M.; Tenore, G.; Palaia, G.; Romeo, U.

    2016-03-01

    Salivary gland diseases can include reactive lesions, obstructive lesions, and benign tumors. All these clinical entities are slow growing. Salivary glands reactive lesions, such as mucoceles, can result from extravasation of saliva into the surrounding soft tissue or from retention of saliva within the duct. Sialolithiasis, one of the most common obstructive lesions, is generally due to calculi, which are attributed to retention of saliva. Monomorphic adenoma is a salivary gland benign tumor, which is exclusively resulted from proliferation of epithelial cells, with no alterations interesting the connective tissue. The elective therapy of these lesions is surgical excision because sometimes they can be accompained by difficulties during chewing and phonation and can interfere with prosthesis's stability. The aim of the study is to evaluate the efficacy of CO2 laser in the treatment of patients with salivary gland diseases. Three different cases - a mucocele, a scialolithiasis and a monomorphic adenoma - were treated with CO2 laser excision (CW and 4W), under local anesthesia. Two different techniques were used: circumferential incision for the adenoma, and mucosa preservation technique for mucocele and sialolithiasis. In each case final haemostasis was obtained by thermocoagulation, but suture was applied to guarantee good healing by sewing up the flaps. The patients were checked after twenty days and the healing was good. The carbon dioxide laser (CO2 laser) was one of the earliest gas laser to be developed, and is still the highest-power continuous wave laser that is currently available. In dentistry the CO2 laser produces a beam of infrared light with the principal wavelength bands centering around 9.4 and 10.6 micrometers. Laser excision can be very useful in oral surgery. In the cases presented CO2 laser offered, differently from traditional surgery, simplified surgical technique, shorter duration of operation, minimal postoperative pain, minimal scarring

  8. Efeitos da radiação laser de dióxido de carbono em tecido ósseo: estudo macroscópico em ratos Effect of carbon dioxide laser radiation on osseous tissue: macroscopic study in rats

    Directory of Open Access Journals (Sweden)

    Walter NICCOLI-FILHO

    2001-06-01

    Full Text Available O laser de dióxido de carbono (CO2, pelas suas propriedades intrínsecas, tem se tornado um instrumento cirúrgico importante; entre estas podemos citar: hemostasia, redução do edema e da dor pós-operatória e esterilização do campo cirúrgico. Seu uso em tecido ósseo para realização de osteotomias ainda é questionável, principalmente devido à possibilidade de iatrogenias causadas pelo aumento da temperatura tecidual, bem como destes efeitos na área paraincisional. O propósito deste estudo foi proporcionar a confecção de um plano piloto visando analisar macroscopicamente os efeitos da radiação laser de CO2 em tíbia de rato a fim de estabelecerem-se parâmetros de segurança quanto a potência. Foram utilizados 12 ratos. Após anestesia, os ossos foram submetidos a radiação com potência de 1, 3 e 5 watts. Os animais foram sacrificados nos tempos imediatamente após, 3, 7 e 14 dias após a irradiação, visando à remoção do osso tratado. Os espécimes obtidos foram observados através de lupa estereoscópica com aumentos de 14, 25 e 40 vezes e fotografados para posterior análise. Os resultados permitiram concluir que a potência de 1 watt proporciona uma melhor qualidade de resposta à reparação e que as potências de 3 e 5 watts provocaram o atraso na cronologia de reparo.The use of CO2 laser in osseous tissue to execute osteotomies is still questionable, mainly due to the increase of temperature in the site of irradiation. The purpose of this research was to carry out a pilot study in order to analyze macroscopically the effect of CO2 laser irradiation on rat tibia and to establish security parameters regarding power. Twelve rats were submitted to irradiation with 1, 3 and 5 watts of power and were examined immediately, 3, 7 and 14 days after irradiation. The results showed better healing when irradiation was carried out with the power of 1 watt; the 3- and 5-watt powers caused delay in the chronology of healing.

  9. Laser Spectroscopy Monitoring of 13C18O16O and 12C17O16O of Atmospheric Carbon Dioxide

    Science.gov (United States)

    Shorter, J. H.; Nelson, D. D.; Ono, S.; McManus, J. B.; Zahniser, M. S.

    2017-12-01

    One of the main challenges to making accurate predictions of future changes in CO2 concentration is the capability to determine what fraction of human produced CO2 remains in the atmosphere. We present our progress in the application of Tunable Infrared Laser Direct Absorption Spectroscopy (TILDAS) to the measurement of the primary clumped (13C18O16O) as well as 17O (12C17O16O) isotopologues of atmospheric CO2, as a tracer of its sources and sinks. We expect unique isotopologue signals in CO2 from high-temperature combustion sources, plants, soils, and air-sea exchange processes. High sampling frequency (a few minutes for each sample vs. reference cycle) achieved by a TILDAS instrument is expected to enable us to document local heterogeneous sources and temporal variations. The TILDAS is equipped with a newly developed 400-meter absorption cell. We designed a dual pressure measurement technique in which the clumped isotopologue, 13C18O16O, and 13C16O16O are first measured at 30 torr cell pressure. This is followed by measurement of 12C17O16O, 12C18O16O and 12C16O16O at lower ( 5 torr) cell pressure. Isotopologue ratios are compared between reference and sample gases. Preliminary tests demonstrated a precision approaching 0.03 ‰ for the ratio 13C18O16O/13C16O16O and 0.08‰ for Δ13C18O16O value (1σ repeatability for 4 min sample vs. reference cycle). Sample size for a single analysis is approximately 100 mL of air (1.6μmol of CO2). Given the previously observed range of variations for Δ13C18O16O and Δ17O values as large as 0.6 to 0.3 ‰, respectively, TILDAS offers a novel approach for real time monitoring of atmospheric CO2 isotopologues. It was found that achieving better than 0.1‰ requires careful matching of CO2 mixing ratios between reference and sample air. A primary cause of pressure and mixing ratio dependence is inaccurate baseline fitting (analogous to abundance sensitivity or pressure baseline for IRMS). Given that mixing ratios of atmospheric

  10. In vivo architectural analysis of clear corneal incisions using anterior segment optical coherence tomography.

    Science.gov (United States)

    Dupont-Monod, Sylvère; Labbé, Antoine; Fayol, Nicolas; Chassignol, Alexis; Bourges, Jean-Louis; Baudouin, Christophe

    2009-03-01

    To use anterior segment optical coherence tomography (AS-OCT) to analyze the in vivo architecture of clear corneal incisions after phacoemulsification using different techniques. Department of Ophthalmology, Quinze-Vingts National Ophthalmology Hospital, Paris, France. This prospective observational study analyzed clear corneal incisions used in phacoemulsification. All wounds were evaluated 1 day and 8 days postoperatively by AS-OCT (Visante). Incision architecture and pachymetry at the wound level were analyzed. Thirty-five clear corneal incisions were analyzed. Six eyes had 2.75 mm coaxial phacoemulsification, 19 had 2.20 mm microincision coaxial phacoemulsification, and 10 had 1.30 mm bimanual microincision phacoemulsification. The 1.30 mm incision had a straight-line configuration. The 2.20 mm and 2.75 mm incisions had an arcuate configuration. The angles of incidence of 1.30 mm incisions were greater than those of 2.20 mm incisions (P<.001). All incisions had slight corneal edema limited to the incision area. The edema was slightly greater around 1.30 mm incisions (mean pachymetry 1143 microm +/- 140 [SD]) than around 2.20 mm incisions (mean 1012 +/- 101 microm) (P = .001). Bimanual procedures had satisfactory endothelial apposition in the enlarged areas, where stromal edema was less than that surrounding the unenlarged 1.30 mm incisions. The 3 phacoemulsification techniques induced gaping of the endothelial edge, minor inadequate endothelial apposition, and mild stromal edema in the area of the clear corneal incisions. Bimanual microincision sleeveless phacoemulsification may alter the wound slightly more than coaxial 2.75 mm and microcoaxial 2.20 mm sleeved-tip phacoemulsification.

  11. Laser Soldering of Rat Skin Using a Controlled Feedback System

    Directory of Open Access Journals (Sweden)

    Mohammad Sadegh Nourbakhsh

    2009-03-01

    Full Text Available Introduction: Laser tissue soldering using albumin and indocyanine green dye (ICG is an effective technique utilized in various surgical procedures. The purpose of this study was to perform laser soldering of rat skin under a feedback control system and compare the results with those obtained using standard sutures. Material and Methods: Skin incisions were made over eight rats’ dorsa, which were subsequently closed using different wound closure interventions in two groups: (a using a temperature controlled infrared detector or (b by suture. Tensile strengths were measured at 2, 5, 7 and 10 days post-incision. Histological examination was performed at the time of sacrifice. Results: Tensile strength results showed that during the initial days following the incisions, the tensile strengths of the sutured samples were greater than the laser samples. However, 10 days after the incisions, the tensile strengths of the laser soldered incisions were higher than the sutured cuts. Histopathological examination showed a preferred wound healing response in the soldered skin compared with the control samples. The healing indices of the laser soldered repairs (426 were significantly better than the control samples (340.5. Conclusion: Tissue feedback control of temperature and optical changes in laser soldering of skin leads to a higher tensile strength and better histological results and hence this method may be considered as an alternative to standard suturing.

  12. Carbon dioxide as chemical feedstock

    National Research Council Canada - National Science Library

    Aresta, M

    2010-01-01

    ... Dioxide as an Inert Solvent for Chemical Syntheses 15 Alessandro Galia and Giuseppe Filardo Introduction 15 Dense Carbon Dioxide as Solvent Medium for Chemical Processes 15 Enzymatic Catalysis in Dense Carbon Dioxide 18 Other Reactions in Dense Carbon Dioxide 19 Polymer Synthesis in Supercritical Carbon Dioxide 20 Chain Polymerizations: Synt...

  13. Preliminary clinical results with the ISL laser

    Science.gov (United States)

    Hoppeler, Thomas; Gloor, Balder

    1992-08-01

    The ISL laser (Intelligent Surgical Lasers, Inc.), a Nd:YLF picosecond pulse laser, is currently being used under investigational device exemption to perform microsurgery of the anterior segment of the eye. At different study sites procedures for cataract fragmentation and iridotomy, as well as for posterior capsulotomy after cataract surgery, are under evaluation. Other potential applications include: sclerostomy ab interno, the cutting of membranes in the anterior and posterior segment of the eye; corneal incisions; and corneal intrastromal effects. We discuss various clinically relevant aspects of the use of this picosecond laser. An overview of different computer controlled laser patterns is given.

  14. Surgical effects on soft tissue produced by a 405-nm violet diode laser in vivo

    Science.gov (United States)

    Miyazaki, H.; Kato, J.; Kawai, S.; Hatayama, H.; Uchida, K.; Otsuki, M.; Tagami, J.; Yokoo, S.

    2011-12-01

    This study evaluated the surgical performance of a 405-nm diode laser in vivo, using living rat liver tissue. Tissue was incised by irradiation with the laser at low output power ranging from 1 W (722 W/cm2) to 3 W (2165 W/cm2) on a manual control at a rate of 1 mm/s. As a control, incisions using a stainless scalpel were compared. Immediately after operation, the surface of the incisions was macroscopically observed and histopathologically evaluated by microscopy. Laser-ablated liver tissue was smooth with observable signs of remnant carbonization and easily acquired hemostasis. The thickness of the denatured layer increased in proportion to the output power; the coagulation layer did not thicken accordingly. Bleeding could not be stopped for tissues incised with the stainless scalpel. The 405-nm diode laser thus proved to be effective for ablating soft tissue with high hemostatic ability at low power.

  15. Signatures of Late Pleistocene fluvial incision in an Alpine landscape

    Science.gov (United States)

    Leith, Kerry; Fox, Matthew; Moore, Jeffrey R.

    2018-02-01

    Uncertainty regarding the relative efficacy of fluvial and glacial erosion has hindered attempts to quantitatively analyse the Pleistocene evolution of alpine landscapes. Here we show that the morphology of major tributaries of the Rhone River, Switzerland, is consistent with that predicted for a landscape shaped primarily by multiple phases of fluvial incision following a period of intense glacial erosion after the mid-Pleistocene transition (∼0.7 Ma). This is despite major ice sheets reoccupying the region during cold intervals since the mid-Pleistocene. We use high-resolution LiDAR data to identify a series of convex reaches within the long-profiles of 18 tributary channels. We propose these reaches represent knickpoints, which developed as regional uplift raised tributary bedrock channels above the local fluvial baselevel during glacial intervals, and migrated upstream as the fluvial system was re-established during interglacial periods. Using a combination of integral long-profile analysis and stream-power modelling, we find that the locations of ∼80% of knickpoints in our study region are consistent with that predicted for a fluvial origin, while the mean residual error over ∼100 km of modelled channels is just 26.3 m. Breaks in cross-valley profiles project toward the elevation of former end-of-interglacial channel elevations, supporting our model results. Calculated long-term uplift rates are within ∼15% of present-day measurements, while modelled rates of bedrock incision range from ∼1 mm/yr for low gradient reaches between knickpoints to ∼6-10 mm/yr close to retreating knickpoints, typical of observed rates in alpine settings. Together, our results reveal approximately 800 m of regional uplift, river incision, and hillslope erosion in the lower half of each tributary catchment since 0.7 Ma.

  16. The extended minimal incision approach to midface rejuvenation.

    Science.gov (United States)

    Pontius, Allison T; Williams, Edwin F

    2005-08-01

    Recent major advancements in comprehensive facial rejuvenation have focused on management of midfacial aging. Multiple techniques have been described to treat the aging midface; the mere nature of so many approaches is evidence that no one technique has prevailed. Although the nasolabial region remains a challenge to correct, the approach described herein provides comprehensive rejuvenation of the midface, lateral brow, and jawline. The technique is performed via a minimal incision brow-lift approach and has been performed (with minor modifications) by the senior author in more than 650 patients over the past 9 years. The technique has proven to be safe, reliable, and effective.

  17. Infrared laser scattering system for the plasma diagnostics: CO/sub 2/ laser characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Hiraki, N; Kawasaki, S; Muraoka, K

    1975-08-01

    A detailed study was conducted of the operating characteristics of a double discharge infrared TEA carbon dioxide laser used for scattering measurements of plasmas. The discharge condition, the laser output energy and power, the beam profile and divergence, the emission spectral line width, the time lag and jitter of the output from the discharge trigger, have been established. It is concluded that the carbon dioxide oscillator can deliver the allowable beam divergence and spectral line width for the measurement of ion temperature in light scattering studies of theta pinch plasmas. The results presented might be applicable to laser fusion experiments using carbon dioxide lasers.

  18. Uranium dioxide pellets

    International Nuclear Information System (INIS)

    Zawidzki, T.W.

    1979-01-01

    Sintered uranium dioxide pellets composed of particles of size > 50 microns suitable for power reactor use are made by incorporating a small amount of sulphur into the uranium dioxide before sintering. The increase in grain size achieved results in an improvement in overall efficiency when such pellets are used in a power reactor. (author)

  19. Classification of titanium dioxide

    International Nuclear Information System (INIS)

    Macias B, L.R.; Garcia C, R.M.; Maya M, M.E.; Ita T, A. De; Palacios G, J.

    2002-01-01

    In this work the X-ray diffraction (XRD), Scanning Electron Microscopy (Sem) and the X-ray Dispersive Energy Spectroscopy techniques are used with the purpose to achieve a complete identification of phases and mixture of phases of a crystalline material as titanium dioxide. The problem for solving consists of being able to distinguish a sample of titanium dioxide being different than a titanium dioxide pigment. A standard sample of titanium dioxide with NIST certificate is used, which indicates a purity of 99.74% for the TiO 2 . The following way is recommended to proceed: a)To make an analysis by means of X-ray diffraction technique to the sample of titanium dioxide pigment and on the standard of titanium dioxide waiting not find differences. b) To make a chemical analysis by the X-ray Dispersive Energy Spectroscopy via in a microscope, taking advantage of the high vacuum since it is oxygen which is analysed and if it is concluded that the aluminium oxide appears in a greater proportion to 1% it is established that is a titanium dioxide pigment, but if it is lesser then it will be only titanium dioxide. This type of analysis is an application of the nuclear techniques useful for the tariff classification of merchandise which is considered as of difficult recognition. (Author)

  20. Systematic review and meta-analysis of electrocautery versus scalpel for surgical skin incisions.

    Science.gov (United States)

    Aird, Lisa N F; Brown, Carl J

    2012-08-01

    The creation of surgical skin incisions has historically been performed using a cold scalpel. The use of electrocautery for this purpose has been controversial with respect to patient safety and surgical efficacy. A systematic review and meta-analysis of randomized controlled trials (RCTs) was conducted to compare skin incisions made by electrocautery and a scalpel. A systematic electronic literature search was performed using 2 electronic databases (MEDLINE and PubMed), and the methodological quality of included publications was evaluated. Six RCTs were identified comparing electrocautery (n = 606) and a scalpel (n = 628) for skin incisions. No significant difference in wound infection rates or scar cosmesis was identified between the treatment groups. Electrocautery significantly reduced the incision time and postoperative wound pain. A trend toward less incisional blood loss from skin incisions made with electrocautery was noted. Electrocautery is a safe and effective method for performing surgical skin incisions. Copyright © 2012 Elsevier Inc. All rights reserved.

  1. Single incision laparoscopic liver resection (SILL – a systematic review

    Directory of Open Access Journals (Sweden)

    Benzing, Christian

    2015-12-01

    Full Text Available Background: Today, minimally invasive liver resections for both benign and malignant tumors are routinely performed. Recently, some authors have described single incision laparoscopic liver resection (SILL procedures. Since SILL is a relatively young branch of laparoscopy, we performed a systematic review of the current literature to collect data on feasibility, perioperative results and oncological outcome.Methods: A literature research was performed on Medline for all studies that met the eligibility criteria. Titles and abstracts were screened by two authors independently. A study was included for review if consensus was obtained by discussion between the authors on the basis of predefined inclusion criteria. A thorough quality assessment of all included studies was performed. Data were analyzed and tabulated according to predefined outcome measures. Synthesis of the results was achieved by narrative review. Results: A total of 15 eligible studies were identified among which there was one prospective cohort study and one randomized controlled trial comparing SILL to multi incision laparoscopic liver resection (MILL. The rest were retrospective case series with a maximum of 24 patients. All studies demonstrated convincing results with regards to feasibility, morbidity and mortality. The rate of wound complications and incisional hernia was low. The cosmetic results were good.Conclusions: This is the first systematic review on SILL including prospective trials. The results of the existing studies reporting on SILL are favorable. However, a large body of scientific evidence on the field of SILL is missing, further randomized controlled studies are urgently needed.

  2. Magnetic resonance imaging evaluation of incision healing after cesarean sections

    Energy Technology Data Exchange (ETDEWEB)

    Dicle, O. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Kuecuekler, C. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Pirnar, T. [Department of Radiodiagnosis, Dokuz Eyluel University, Izmir (Turkey); Erata, Y. [Department of Gynecology and Obstetrics, Dokuz Eyluel University, Izmir (Turkey); Posaci, C. [Department of Gynecology and Obstetrics, Dokuz Eyluel University, Izmir (Turkey)

    1997-02-01

    The purpose of this study was to examine the healing period of incision scar in myometrial wall and the normal pelvis after cesarean sections by means of MRI. In this study 17 voluntary women were examined after their first delivery with cesarean section in the early postpartum period (first 5 days), and following this, three more times in 3-month intervals. The MRI examinations were performed on a 1.0-T system (Magnetom, Siemens, Erlangen, Germany), and sagittal T1-weighted (550/17 TR/TE) and T2-weighted (2000/80 TR/TE) spin-echo (SE) images of the pelvis were obtained. During follow-up examinations incision scar tissues lost their signals within the first 3 months on both SE sequences, and little alteration was observed in the subsequent tests. Zonal anatomy of the uterus reappeared completely 6 months after cesarean sections. The time for the involution of the uterus was independent of the zonal anatomy recovery, and the maximum involution was inspected within the first 3 months. In conclusion, the maturation time of myometrial scar tissue in uncomplicated cesarean sections, which can be evaluated by the signal alterations in MRI, is approximately 3 months, whereas the complete involution and the recovery of the zonal anatomy need at least 6 months. (orig.). With 6 figs.

  3. Muscle sparing lateral thoracotomy: the standard incision for thoracic procedures

    Directory of Open Access Journals (Sweden)

    Mihai Dumitrescu

    2017-05-01

    Full Text Available Lateral thoracotomy is a versatile approach with many variations and is currently the most widely used incision in thoracic surgery. In the current article we are presenting the muscle-sparing lateral thoracotomy in the lateral decubitus position which we consider to be the “standard” for lateral thoracotomies. Indications, surgical technique and pitfalls are described alongside our experience with thoracic drainage. Although there is no consensus regarding the name of this incision, some authors call it “axillary thoracotomy” while others call it a “modified lateral thoracotomy”, they all agree on one aspect – the importance of muscle sparing – which makes it the go-to thoracotomy for both small and large procedures involving the lung. Lateral muscle sparing thoracotomy allows for good exposure of the pulmonary hilum, fissures, apex and diaphragm. The approach is easy and quick to perform while at the same time ensuring faster postoperative recovery by sparing the latissimus dorsi muscle, better cosmetics and lower postoperative pain score when compared to the posterolateral or classical lateral thoracotomies.

  4. Magnetic resonance imaging evaluation of incision healing after cesarean sections

    International Nuclear Information System (INIS)

    Dicle, O.; Kuecuekler, C.; Pirnar, T.; Erata, Y.; Posaci, C.

    1997-01-01

    The purpose of this study was to examine the healing period of incision scar in myometrial wall and the normal pelvis after cesarean sections by means of MRI. In this study 17 voluntary women were examined after their first delivery with cesarean section in the early postpartum period (first 5 days), and following this, three more times in 3-month intervals. The MRI examinations were performed on a 1.0-T system (Magnetom, Siemens, Erlangen, Germany), and sagittal T1-weighted (550/17 TR/TE) and T2-weighted (2000/80 TR/TE) spin-echo (SE) images of the pelvis were obtained. During follow-up examinations incision scar tissues lost their signals within the first 3 months on both SE sequences, and little alteration was observed in the subsequent tests. Zonal anatomy of the uterus reappeared completely 6 months after cesarean sections. The time for the involution of the uterus was independent of the zonal anatomy recovery, and the maximum involution was inspected within the first 3 months. In conclusion, the maturation time of myometrial scar tissue in uncomplicated cesarean sections, which can be evaluated by the signal alterations in MRI, is approximately 3 months, whereas the complete involution and the recovery of the zonal anatomy need at least 6 months. (orig.). With 6 figs

  5. Discussion on the Relevant Factors of General Surgery Incision Infection and Prevention Methods

    Directory of Open Access Journals (Sweden)

    Jin Baotao

    2017-01-01

    Full Text Available There are many reasons that can lead to incision infection of general surgical patients. The main reasons include weight, age, body albumin level, surgical time, observation ward, etc. This paper analyzes the clinic data of patients with incision infection after general surgery based on clinic practice and study on the reasons that have impact on general surgical incision infection and gives relevant prevention countermeasures.

  6. Long-Term Incisal Relationships After Palatoplasty in Patients With Isolated Cleft Palate.

    Science.gov (United States)

    Odom, Elizabeth B; Woo, Albert S; Mendonca, Derick A; Huebener, Donald V; Nissen, Richard J; Skolnick, Gary B; Patel, Kamlesh B

    2016-06-01

    Various palatoplasty techniques have limited incisions in the hard palate due to concerns that these incisions may limit maxillary growth. There is little convincing long-term evidence to support this. Our purpose is to determine incisal relationships, an indicator for future orthognathic procedure, in patients after repair of an isolated cleft of the secondary palate. Our craniofacial database was used to identify patients aged 10 years or greater with an isolated cleft of the secondary palate who underwent palatoplasty between 1985 and 2002. Data collected included age at palatoplasty and follow-up, cleft type, associated syndrome, Robin sequence, surgeon, repair technique, number of operations, and occlusion. Incisal relationship was determined through clinical observation by a pediatric dentist and orthodontist. Seventy eligible patients operated on by 9 surgeons were identified. Class III incisal relationship was seen in 5 patients (7.1%). Palatoplasty techniques over the hard palate (63 of 70 patients) included 2-flap palatoplasty, VY-pushback, and Von Langenbeck repair. There was an association between class III incisal relationship and syndromic diagnosis (P <0.001). Other study variables were not associated with class III incisal relationships. In patients with an isolated cleft of the secondary palate, there was no association between class III incisal relationship and surgeon, age at repair, cleft type, palatoplasty technique, or number of operations. Increased likelihood of class III incisal relationship was associated primarily with syndromic diagnosis.

  7. Midline versus transverse incision for cesarean delivery in low-income countries

    DEFF Research Database (Denmark)

    Maaløe, Nanna; Aabakke, Anna J M; Secher, Niels J

    2014-01-01

    While transverse incision is the recommended entry technique for cesarean delivery in high-income countries, it is our experience that midline incision is still used routinely in many low-income settings. Accordingly, international guidelines lack uniformity on this matter. Although evidence...... is limited, the literature suggests important advantages of the transverse incision, with lower risk of long-term disabilities such as wound disruption and hernia. Also, potential extra time spent on this incision appears not to impact neonatal outcome. Therefore, we suggest that it is time for a change...

  8. Diathermy vs. scalpel skin incisions in general surgery: double-blind, randomized, clinical trial.

    Science.gov (United States)

    Shamim, Muhammad

    2009-08-01

    This prospective, double-blind, randomized, controlled trial was designed to compare the outcome of diathermy incisions versus scalpel incisions in general surgery. A total of 369 patients who underwent diathermy incision (group A: 185 patients) or scalpel incision (group B: 184 patients) were analyzed. Variables analyzed were: surgical wound classification, length and depth of incision, incision time, duration of operation, incisional blood loss, postoperative pain, duration of hospital stay, duration of healing, and postoperative complications. The inclusion criteria were all patients who underwent elective or emergency general surgery. The exclusion criteria were only cases with incomplete patients' data and patients who were lost to follow-up. This study was conducted at Fatima Hospital-Baqai Medical University and Shamsi Hospital (Karachi), from January 2006 to December 2007. Incision time was significantly longer for patients in group B (p = 0.001). Incisional blood loss also was more for patients in group B (p = 0.000). Pain perception was found to be markedly reduced during the first 48 h in group A (p = 0.000). Total period of hospital stay (p = 0.129) and time for complete wound healing (p = 0.683) were almost the same for both groups. Postoperative complication rate by wound classification did not differ markedly between the two groups (p = 0.002 vs. p = 0.000). Diathermy incision has significant advantages compared with the scalpel because of reduced incision time, less blood loss, & reduced early postoperative pain.

  9. Advantages of the modified double ring areolar incision over the traditional areolar incision in multicentric breast fibroadenoma surgery.

    Science.gov (United States)

    Zhang, Mingliang; Shen, Gongjin; Zhang, Song; Cui, Zhen; Qian, Jun

    2017-09-01

    This study was conducted to investigate the clinical advantages of modified double ring areola incision (MDRAI) compared to ordinary areola incision (OAI) in multicentric breast fibroadenoma in women. Sixty cases of multicentric benign breast tumor were recruited from the First Affiliated Hospital of Bengbu Medical College from January to December 2016. The cases were divided into two groups according to surgical approach: MDRAI (n = 20) and OAI (n = 40). The operation duration, intraoperative blood loss, drainage time, and postoperative recurrence rate in the first six months were compared. The mean age and tumor locations were not statistically different between the groups (P > 0.05). However, more lesions and larger tumor diameter were found in the MDRAI group than in the OAI group, with statistical difference (P  0.05). However, the intraoperative blood loss was statistically different between the two groups (P < 0.05). All 60 cases received six months of follow-up. Eight recurrent cases were found in the OAI group, but none in the MDRAI group. The recurrence rate was significantly different (χ 2  = 4.62, P < 0.05). Compared with OAI, MDRAI offers greater advantages in the aspects of blood loss and recurrence for the treatment of breast benign tumor, especially for multicentric larger lesions. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.

  10. Long-term Results of Small-incision Lenticule Extraction in High Myopia

    Directory of Open Access Journals (Sweden)

    Yusuf Yıldırım

    2016-10-01

    Full Text Available Objectives: To evaluate two-year results of small-incision lenticule extraction (SMILE for correction of high myopia. Materials and Methods: Forty-five eyes of 35 patients with mean spherical equivalent (SE of -7.10±0.95 D who underwent routine SMILE by a single surgeon and were followed for at least 2 years were analyzed by retrospective chart review. SMILE was performed with a Visumax femtosecond laser (Carl Zeiss Meditec, Jena, Germany. Follow-up intervals were at 1, 6, 12, and 24 months after surgery. Uncorrected and best corrected distance visual acuity (CDVA, corneal wavefront measurements, and all complications were recorded. Results: After 2 years, 86% of eyes with plano target had an uncorrected distant visual acuity (VA of 20/20 or better. Two percent of eyes lost 1 line of CDVA, while 32% gained 1 line. The mean SE after 2 years was -0.30±0.50 D. Corneal total high-order aberrations (HOA increased from 0.43 to 0.92 μm at postoperative 12 months. There were metallic foreign bodies at the corneal interface in 1 eye of 1 patient which caused no decrease in VA. Conclusion: SMILE for high myopia seems safe and effective in light of two-year follow-up results. The procedure caused a moderate increase in HOA.

  11. Mouse preferential incising force orientation changes during jaw closing muscle hyperalgesia and is sex dependent.

    Science.gov (United States)

    Widmer, C G; Morris-Wiman, J

    2016-12-01

    Mouse incising is controlled by a central pattern generator and this activity can change in the presence of pain. The incising frequency and maximum force generation decreases with pain. In this study, we used repetitive acidic injections in the left masseter muscle of male and female mice to determine differences between baseline and jaw muscle pain conditions and the effect of sex on preferential incising direction. A within subject design was used to evaluate data previously acquired using multi-axis force data (X, Y and Z) from the 4th baseline recording day and day 7 post-injection (day of maximal pain response) for each mouse of each sex. A total of 34 female and male (age 3-9months) CD-1 mice were evaluated. After mathematically rotating the X and Y axes to align the Y axis to be parallel to the wire struts of the cage top, data were analyzed to determine incising direction preference during baseline (non-pain) and pain (day 7) conditions and between sex. Radar plots of X-Y, X-Z and Y-Z axes depicted the average direction of incising preference between baseline and pain conditions for each sex. Statistical differences among groups were tested using a mixed model ANOVA. Similar to previous findings, female mice had a more robust difference in incising direction preference when comparing male and female pain conditions and this was most evident in the X-Z axes. The incising frequencies most commonly affected were 5.3, 6.2 and 7.6Hz. Male mice varied little in their incising direction preference between the baseline and pain conditions. In addition, statistical comparison of ratios of the percent of time spent incising in the Z versus X axes for each incising frequency found that the incising preference was not different when comparing 5.3 and 7.6Hz frequencies. Finally, female mice used a novel approach to minimize pain while incising by rotating their head and body nearly 180 degrees while males did not use this strategy as frequently. The preferred incising

  12. Clear corneal incision leakage after phacoemulsification--detection using povidone iodine 5%.

    Science.gov (United States)

    Chee, Soon-Phaik

    2005-01-01

    The purpose of this work was to study the incidence of clear corneal wound leakage at the conclusion of standard co-axial phacoemulsification in a prospective observational series of 100 consecutive cataract cases in a single surgeon's institutional practice. At the conclusion of standard co-axial phacoemulsification using a 2.75 mm temporal single plane clear corneal incision with a 1 mm clear corneal side-port incision, the wounds were hydrated and checked for water-tightness. Povidone iodine 5% (P-I) was then evenly dripped over the cornea and the wounds were inspected visually. Any leakage of aqueous observed was recorded. The amount of leakage was graded as small or large from each wound. Leaky wounds were further hydrated and retested with P-I until sealed. Wound integrity was reassessed on the first postoperative day by use of fluorescein. Of the 100 cases, wound leakage was observed for 31 eyes (31%)-ten main incisions, nineteen side-port incisions, and both incisions in two cases. Wound leakage was easily detected as a ribbon of clear fluid streaming from the incision amid a pool of brown solution. Povidone iodine was not observed within the tract in any incision. All wound leakage was small except for one from the main incision and two from the side-port incision. None of the eyes developed wound leakage the day after surgery and none developed endophthalmitis. In conclusion, leakage from clear corneal incisions at the conclusion of phacoemulsification occurs in almost a third of cases, predominantly from the side incision. It is easily detected by use of the P-I test.

  13. Effects of post-treatment incubation on recombinogenesis in incision-proficient and incision-deficient strains of saccharomyces cerevisiae, 2

    International Nuclear Information System (INIS)

    Saeki, Tetsuya; Machida, Isamu

    1991-01-01

    After the photoaddition of mono- and bifunctional furocoumarins to G1 phase cells, most gene conversion and crossing-over occurred without post-irradiation incubation of these cells in incision-proficient strains. In contrast, incision-deficient cells showed marked induction of both recombinational events only after treated cells had been incubated for several hours before selection. These results indicate that when furocoumarins are photoadded to G1 cells, initiation of recombinational events occurs during the same G1 phase in the incision-proficient cells; whereas, it occurs only after post-irradiation DNA replication in incision-deficient cells. The action of the PSO2 gene product specific for the repair of DNA crosslinks in recombination induction is discussed and compared to the actions of the excision repair genes RAD1 and RAD2. (author)

  14. Median sternotomy - gold standard incision for cardiac surgeons

    Directory of Open Access Journals (Sweden)

    Radu Matache

    2016-05-01

    Full Text Available Sternotomy is the gold standard incision for cardiac surgeons but it is also used in thoracic surgery especially for mediastinal, tracheal and main stem bronchus surgery. The surgical technique is well established and identification of the correct anatomic landmarks, midline tissue preparation, osteotomy and bleeding control are important steps of the procedure. Correct sternal closure is vital for avoiding short- and long-term morbidity and mortality. The two sternal halves have to be well approximated to facilitate healing of the bone and to avoid instability, which is a risk factor for wound infection. New suture materials and techniques would be expected to be developed to further improve the patients evolution, in respect to both immediate postoperative period and long-term morbidity and mortality

  15. Mandibular incisive canal in relation to periapical surgery

    Directory of Open Access Journals (Sweden)

    Kani Bilginaylar

    2016-01-01

    Full Text Available The aim of the present paper is to emphasize the importance of the mandibular interforaminal neurovascular bundle with a case and make a warning to dentists and surgeons during oral and maxillofacial surgeries, such as implant replacement, bone harvesting, genioplasty, open reduction of a mandibular fracture, and cyst enucleations at this region. In this paper, we present a 58-year-old male who referred with pain and a tingling sensation on the left lower lip. After radiographical, extraoral and intraoral examinations, findings indicated the lesion to be a cyst which was related with a periapical lesion of the canine tooth and extracted socket of first premolar tooth. After removal of a cyst, the mandibular incisive nerve was documented which was in relation to cyst cavity.

  16. Incisiones verticales en SARPE Vertical incisions in SARPE

    Directory of Open Access Journals (Sweden)

    J. Gonzalez Lagunas

    2005-06-01

    Full Text Available La expansión rápida de paladar asistida quirúrgicamente (SARPE es una de las opciones terapeuticas de los transtornos transversales del maxilar superior. Presentamos nuestra experiencia inicial con una variante técnica consistente en una corticotomía de la pared lateral del maxilar combinada con una osteotomía palatina media transincisal, y efectuadas a través de tres pequeñas incisiones verticales.Surgically assisted rapid palatal expansion (SARPE is one of the therapeutic options for the correction of transverse maxillary collapse. We present our initial experience with a technique consisting in a lateral corticotomy of the maxilla plus a transincisal midpalatal osteotomy, both performed through minimal vertical incisions.

  17. A case of bifocal endometriosis involving a pfannenstiel incision.

    Science.gov (United States)

    Evsen, Mehmet Sidik; Sak, Muhammet Erdal; Yalinkaya, Ahmet; Firat, Ugur; Caca, Fatma Nur

    2011-01-01

    A 25-year-old woman was referred to our clinic for atypical cyclic pain and masses at both ends of a Pfannenstiel incision scar. Ultrasound of the anterior abdominal wall showed two masses. Both masses were hypoechoic, heterogeneous lesions located at opposite ends of the scar. The lesions were surgically excised with. Microscopic examination revealed endometrial gland structures with endometrial stroma in fibroadipose tissue in sections of both specimens indicative of endometriosis. Incisional endometriosis (IE) is a form of extrapelvic endometriosis especially in scars of obstetric or gynecologic surgery IE may be multifocal at surgical scars. We report the a case of bifocal incisional endometriosis in Pfannesteil scar. Whole scar evaluation should be done for incisional endometriosis and surgical excision should be performed for treatment.

  18. Uranium dioxide. Sintering test

    International Nuclear Information System (INIS)

    Anon.

    Description of a sintering method and of the equipment devoted to uranium dioxide powder caracterization and comparison between different samples. Determination of the curve giving specific volume versus pressure and micrographic examination of a pellet at medium pressure [fr

  19. Performance of fast-absorbable suture and histo-glue in closing incisions in Brown trout

    DEFF Research Database (Denmark)

    Jepsen, Niels; Larsen, Martin Hage; Aarestrup, Kim

    2017-01-01

    , growth, tag expulsion rate and incision healing was compared among three groups of dummy transmitter-tagged wild brown trout Salmo trutta where incisions were closed with two types of suture material (absorbable vs. fast absorbable) and Histo-glue. The tagged fish were kept in semi-natural ponds for 20...

  20. 21 CFR 884.4550 - Gynecologic surgical laser.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gynecologic surgical laser. 884.4550 Section 884....4550 Gynecologic surgical laser. (a) Identification. A gynecologic surgical laser is a continuous wave carbon dioxide laser designed to destroy tissue thermally or to remove tissue by radiant light energy...

  1. Inertial fusion by laser

    International Nuclear Information System (INIS)

    Dautray, R.; Watteau, J.-P.

    1980-01-01

    Following a brief historical survey of research into the effects of interaction of laser with matter, the principles of fusion by inertial confinement are described and the main parameters and possible levels given. The development of power lasers is then discussed with details of performances of the main lasers used in various laboratories, and with an assessment of the respective merits of neodymium glass, carbon dioxide or iodine lasers. The phenomena of laser radiation and its interaction with matter is then described, with emphasis on the results of experiments concerned with target implosion with the object of compressing and heating the mixture of heavy hydrogen and tritium to be ignited. Finally, a review is made of future possibilities opened up by the use of large power lasers which have recently become operational or are being constructed, and the ground still to be covered before a reactor can be produced [fr

  2. Ectasia following small-incision lenticule extraction (SMILE: a review of the literature

    Directory of Open Access Journals (Sweden)

    Moshirfar M

    2017-09-01

    considered absolute contraindications to the procedure. Three patients were identified to have high risk based on the ERSS, and one patient exhibited a PTA ≥40%. We formulated a modification to the current calculation of PTA that takes into account the differences in tissue altered between SMILE and laser in situ keratomileusis (LASIK. More studies are needed to fully quantify the risk of ectasia. For now, we propose adopting the same exclusion criteria used for LASIK in the SMILE procedure until more specific metrics have been validated. Keywords: SMILE, small-incision lenticule extraction, ectasia, keratoconus, percent tissue altered, Ectasia Risk Score System

  3. Thermal study of bare tips with various system parameters and incision sizes.

    Science.gov (United States)

    Osher, Robert H; Injev, Valentine P

    2006-05-01

    To identify major and minor surgeon-controlled parameters that affect incision temperature when performing microincision lens removal using the Alcon Infiniti Vision System. In vitro research and development laboratory, Alcon Research, Irvine, California, USA. Phacoemulsification was performed in eye-bank cadaver eyes and the following parameters evaluated: incision, duty cycle, ultrasound (US) power, aspiration flow rate (AFR), vacuum, pulse, bottle height and balanced salt solution temperature, and tip design/size. Each parameter was varied while the others remained constant. The resulting temperature of the incision and US tip was measured using a thermal camera. Major contributors to elevated incision temperature included incision size, US power, duty cycle, AFR, vacuum setting, tip design, and presence of an ophthalmic viscosurgical device (OVD). Minor contributors included pulse frequency, bottle height, and temperature of the infusate. Microincision lens removal can be performed at safe temperatures with the knowledgeable selection of surgeon-controlled parameters.

  4. Single-incision laparoscopic surgery through an ostomy site: a natural approach by an unnatural orifice.

    Science.gov (United States)

    Lopez, Nicole E; Peterson, Carrie Y; Ramamoorthy, Sonia L; McLemore, Elisabeth C; Sedrak, Michael F; Lowy, Andrew M; Horgan, Santiago; Talamini, Mark A; Sicklick, Jason K

    2015-02-01

    Single-incision laparoscopic surgery (SILS) is gaining popularity for a wide variety of surgical operations and capitalizes on the benefits of traditional laparoscopic surgery without incurring multiple incision sites. Traditionally, SILS is performed by a midline periumbilical approach. However, such a minimally invasive approach may be utilized in patients who already have an abdominal incision. Our series retrospectively reviews 7 cases in which we utilized the fascial defect at the time of after ostomy reversal as our SILS incision site. In turn, we performed a variety of concurrent intra-abdominal procedures with excellent technical success and outcomes. Our study is the largest single-institution case series of this novel approach and suggests that utilizing an existing ostomy-site abdominal incision is a safe and effective location for SILS port placement and should be considered in patients undergoing concurrent procedures.

  5. Recent, climate-driven river incision rate fluctuations in the Mercantour crystalline massif, southern French Alps

    Science.gov (United States)

    Petit, C.; Goren, L.; Rolland, Y.; Bourlès, D.; Braucher, R.; Saillard, M.; Cassol, D.

    2017-06-01

    We present a new geomorphological analysis of the Tinée River tributaries in the southern French Alps based on numerical inverse and forward modelling of their longitudinal profiles. We model their relative uplift history with respect to the main channel, hence the incision rate history of this channel. Inverse models show that all tributaries have consistent incision rate histories with alternating high and low values. A comparison with global temperature curves shows that these variations correlate with quaternary climate changes. We suggest that during warm periods, a wave of regressive erosion propagates in the Tinée River, while its tributaries deeply incise their substratum to catch up with the falling base-level. We also show that the post 140 ka history of this landscape evolution is dominated by fluvial incision. We then perform forward models of river incision and simulate the incision of the Tinée River system over a time span of 600 ka. This model allows us to extract time and space incision rate variations of the Tinée River. With a background of a few mm.yr-1, incision rate can increase up to more than 1 cm yr-1 during short periods of time due to climatic oscillations. This result is compatible with published cosmogenic nuclide based dating, which evidenced incision rates from 0.2 to 24 mm yr-1. The part of the channel located between 12 and 20 km downstream from the source has undergone several periods of rapid incision rates, which could explain the steep hillslopes and the triggering of a landslide ∼10 ka ago.

  6. STUDY OF VARIOUS MODALITIES IN MANAGEMENT OF INCISION HERNIA REPAIR

    Directory of Open Access Journals (Sweden)

    Raghu Rachha

    2018-03-01

    Full Text Available BACKGROUND Incisional hernias are a major problem following abdominal surgery and their repairs are among the common surgeries done by a general surgeon.1 Besides the preoperative factors such as anaemia, BMI over 25 kg/m2 and smoking which are leading causes contributing to the development of Incisional hernia, laparotomy performed through the abdominal incision doubles the risk of IH.2 In addition, wound infection, increases the risk of IH formation by 1.9 times.3 If left unattended they may attain large size therefore cause discomfort and lead to the complications like Obstruction, Strangulation, Incarceration increasing the risk of morbidity and mortality.4 Treatment of IH involves further major surgery and the results may be poor, with the recurrence rates of up to 49% reported.5 A wide spectrum of surgical techniques have been developed and recommended ranging from sutured techniques to the various types of prosthetic mesh. MATERIALS AND METHODS 30 patients were studied who presented to emergency department with incisional hernias during August 2014 – September 2016 at Gandhi Medical College and Hospital. All patients underwent definitive treatment. RESULTS From our study it is observed that 1. The maximum cases of incisional hernias presenting to the emergency surgical department were found to be in 51-60 years age group. 2. There was female preponderance. 3. Obstruction is the most common presenting symptom found in 60% of cases followed by irreducibility (33.3% and strangulation (6.67%. 4. The onset of incisional hernias is more after 10 years following previous surgery. 5. Among 30 patients, bowel was viable in 18 patients (60% and mesh repair was done in 13 patients. Bowel was gangrenous in 12 patients (40% and anatomical repair was done in 17 patients. 6. Out of 30, women got infected in 11 patients (36.67% wound dehiscence noted in 5 patients (16.67%. 7. The recurrence rate was 6.67% with 6 months follow up. CONCLUSION 1. The mean

  7. De Qeurvian Tenosynovitis: Clinical Outcomes of Surgical Treatment with Longitudinal and Transverse Incision

    Directory of Open Access Journals (Sweden)

    Arefah Dehghani Tafti

    2011-03-01

    Full Text Available AbstractObjectives: De Quervain disease is a mechanical tenosynovitis due to inadequacy volume between abductor pollicis longus, extensor pollicis brevis and their tunnel. Treatment methods include immobilization, steroid injections, and operation. For the first time Fritz De Quervain described surgical treatment of this disease. Since then, various ways of treatment have been reported. The purpose of this study is to compare the clinical outcomes of a longitudinal incision with a transverse incision in De Quervain disease.Methods: This was a randomized controlled clinical trial conducted in three hospitals in Iran, Yazd from March 2003 to September 2008. One hundred-twenty patients with De Quervain disease who did not respond to conservative treatment were operated with two different incisions. The patients were followed for three months to compare the surgical outcomes.Results: During a three month follow-up, a significant difference was shown between the two methods (p=0.03. Results of surgical treatment with longitudinal incision were excellent (only 5 hypertrophic scars, but there were 13 postoperative complaints with transverse incision.Conclusion: According to our findings, longitudinal incision in surgical treatment of De Quervain disease is better than transverse incision.

  8. Nuclear management in manual small incision cataract surgery by snare technique

    Directory of Open Access Journals (Sweden)

    Bhattacharya Debasish

    2009-01-01

    Full Text Available Manual small incision cataract surgery has evolved into a popular method of cataract surgery in India. However, in supra hard cataract, bringing out the whole nucleus through the sclerocorneal flap valve incision becomes difficult. A bigger incision required in such cataracts loses its value action, as the internal incision and corneal valve slips beyond the limbus into sclera. Struggling with the supra hard cataracts through a regular small incision. Phacofracture in the anterior chamber becomes a useful option in these cases. In the snare technique, a stainless steel wire loop when lassoed around the nucleus in the anterior chamber constricts from the equator, easily dividing the hardest of the nuclei into two halves. The wire loop constricts in a controlled way when the second cannula of snare is pulled. The divided halves can easily be brought out by serrated crocodile forceps. This nuclear management can be safely performed through a smaller sclerocorneal flap valve incision where the corneal valve action is retained within the limbus without sutures, and the endothelium or the incision is not disturbed. However, the technique requires space in the anterior chamber to maneuver the wire loop and anterior chamber depth more than 2.5 mm is recommended. Much evidence to this wonderful technique is not available in literature, as its popularity grew through live surgical workshops and small interactive conferences.

  9. Use of the Femtosecond Lasers in Ophthalmology

    Directory of Open Access Journals (Sweden)

    Roszkowska Anna M

    2018-01-01

    Full Text Available Femtosecond laser (FSL is an infrared laser with a wavelength of 1053 nm. FS laser works producing photodisruption or photoionization of the optically transparent tissue such as cornea. Currently FS lasers have a wide range of applications in ophthalmic surgery. They are used above all in corneal surgery in refractive procedures and keratoplasty, and recently in cataract surgery. The use of the FSL in corneal refractive surgery includes LASIK flap creation, astigmatic keratotomy, Femtosecond Lenticule Extraction (FLEx, Small Incision Lenticule Extraction (SMILE and channels creation for implantation of the intrastromal corneal rings. As to the corneal grafting, the FS lasers are used in laser-assisted anterior and posterior lamellar keratoplasty and customized trephination in the penetrating keratoplasty. FS Laser Assisted Cataract Surgery (FLACS includes capsulorrhexis and nuclear fragmentation that enhance safety and efficacy of the procedure.

  10. Use of the Femtosecond Lasers in Ophthalmology

    Science.gov (United States)

    Roszkowska, Anna M.; Urso, Mario; Signorino, Alberto; Aragona, Pasquale

    2018-01-01

    Femtosecond laser (FSL) is an infrared laser with a wavelength of 1053 nm. FS laser works producing photodisruption or photoionization of the optically transparent tissue such as cornea. Currently FS lasers have a wide range of applications in ophthalmic surgery. They are used above all in corneal surgery in refractive procedures and keratoplasty, and recently in cataract surgery. The use of the FSL in corneal refractive surgery includes LASIK flap creation, astigmatic keratotomy, Femtosecond Lenticule Extraction (FLEx), Small Incision Lenticule Extraction (SMILE) and channels creation for implantation of the intrastromal corneal rings. As to the corneal grafting, the FS lasers are used in laser-assisted anterior and posterior lamellar keratoplasty and customized trephination in the penetrating keratoplasty. FS Laser Assisted Cataract Surgery (FLACS) includes capsulorrhexis and nuclear fragmentation that enhance safety and efficacy of the procedure.

  11. Carbon dioxide and climate

    International Nuclear Information System (INIS)

    1991-10-01

    Global climate change is a serious environmental concern, and the US has developed ''An Action Agenda'' to deal with it. At the heart of the US effort is the US Global Change Research Program (USGCRP), which has been developed by the Committee on Earth and Environmental Sciences (CEES) of the Federal Coordinating Council for Sciences, Engineering, and Technology (FCCSET). The USGCRP will provide the scientific basis for sound policy making on the climate-change issue. The DOE contribution to the USGCRP is the Carbon Dioxide Research Program, which now places particular emphasis on the rapid improvement of the capability to predict global and regional climate change. DOE's Carbon Dioxide Research Program has been addressing the carbon dioxide-climate change connection for more than twelve years and has provided a solid scientific foundation for the USGCRP. The expansion of the DOE effort reflects the increased attention that the Department has placed on the issue and is reflected in the National Energy Strategy (NES) that was released in 1991. This Program Summary describes projects funded by the Carbon Dioxide Research Program during FY 1991 and gives a brief overview of objectives, organization, and accomplishments. The Environmental Sciences Division of the Office of Health and Environmental Research, Office of Energy Research supports a Carbon Dioxide Research Program to determine the scientific linkage between the rise of greenhouse gases in the atmosphere, especially carbon dioxide, and climate and vegetation change. One facet is the Core CO 2 Program, a pioneering program that DOE established more than 10 years ago to understand and predict the ways that fossil-fuel burning could affect atmospheric CO 2 concentration, global climate, and the Earth's biosphere. Major research areas are: global carbon cycle; climate detection and models of climate change; vegetation research; resource analysis; and, information and integration

  12. Deposition of carbon dioxide

    International Nuclear Information System (INIS)

    2001-01-01

    In Norway, there is currently a debate about whether or not to build gas power stations. To meet the possibility of reduced emission quotas for carbon dioxide in the future, current interest focuses on the incorporation of large-scale separation and deposition of carbon dioxide when such plants are planned. A group of experts concludes that this technology will become self-financing by means of environmental taxes. From the environmental point of view, taxes upon production are to be preferred over taxes on consumption

  13. Ultrasonographic evaluation of the healing of ventral midline abdominal incisions in the horse.

    Science.gov (United States)

    Wilson, D A; Badertscher, R R; Boero, M J; Baker, G J; Foreman, J H

    1989-06-01

    Ultrasonography was used to evaluate the ventral midline incisions of 21 ponies following exploratory laparotomy. The incisions were evaluated before surgery and at weekly intervals from one to seven weeks after surgery. Both 5.0 and 7.5 MHz linear array and 7.5 MHz sector transducers were used for the evaluations. The incisional complications observed were drainage, oedema, suture sinus formation, suture abscess, superficial dehiscence and incisional hernia. Ultrasonographic imaging of the ventral midline incision was an easy, reliable and objective method for detecting and monitoring the progression of incisional complications in a non-invasive manner.

  14. Towards achieving small-incision cataract surgery 99.8% of the time.

    Directory of Open Access Journals (Sweden)

    Thomas R

    2000-01-01

    Full Text Available A surgical approach designed to reliably attain the modern goal of small incision cataract surgery 99.8% of the time is described. Phacoemulsification as well as a manual small incision technique is utilised to achieve the desired outcome as often as possible and for all types of cataracts. The logic, and required surgical steps are described and illustrated. This surgical technique allows the advantages of small incision surgery to be reliably achieved. The method is flexible and allows decisions and steps to be modified depending on the skill and comfort zone of the individual surgeon.

  15. Techniques for creating inconspicuous face-lift scars: avoiding visible incisions and loss of temporal hair.

    Science.gov (United States)

    Kridel, Russell W H; Liu, Edmund S

    2003-01-01

    Patients seeking rhytidectomy desire an improved neckline, jawline, and midface, but rarely at the price of signs that betray a face-lift, namely, visible incisions. We describe our face-lift incisional planning and the rationale behind specific surgical maneuvers for preventing unwanted sequelae. The telltale signs of poorly placed incisions include temporal hair loss, conspicuous scars, an unnatural appearance to the tragus, and a posterior hairline distorsion. Special considerations are given to the male patient and to the salvage of readily visible incision lines from previous surgery.

  16. Transverse versus Longitudinal Incisions for Femoral Artery Exposure in Treating Patients with Peripheral Vascular Disease.

    Science.gov (United States)

    Parikh, Punam P; Rubio, Gustavo A; Patel, Kunal; Gupta, Kapil; Jones, Keith; Rey, Jorge; Robinson, Handel

    2018-02-01

    This study evaluates differences in wound complication rate when transverse versus longitudinal incision is utilized to expose femoral vessels in managing patients with peripheral vascular disease. A retrospective review from 2013 to 2015 was conducted of 150 patients undergoing 156 lower extremity revascularizations with femoral artery exposure through a groin incision. Patients were stratified into 2 groups, transverse versus longitudinal groin incision. Data were reviewed for 3 surgeons that utilize either transverse or longitudinal groin incision in patients undergoing common or iliofemoral endarterectomies, or where femoral artery was used as inflow and/or outflow vessel for limb revascularization. Each group had a comparative outcomes analysis based on incision type. The primary outcome was wound complication, defined as any wound infection, lymphocele, hematoma, dehiscence, pseudoaneurysm, or necrosis. Other outcomes studied included unplanned return to operating room for wound complication, wound vacuum therapy, and soft-tissue flap closure. Data were analyzed using 2-tailed chi-squared test and Student's t-test. Patients in the transverse (n = 85 cases) versus longitudinal (n = 71 cases) cohorts were similar in relation to demographics and comorbidities. Overall mean follow-up was 220 days. Patients with a transverse as compared to longitudinal incision had a significantly lower overall wound complication rate, 7% vs. 42%, respectively (P transverse incisions were associated with lower incidence of unplanned return to the operating room to manage wound complications than patients with a longitudinal incision (5% vs. 23%, respectively; P Transverse versus longitudinal incisions were also associated with significantly lower need for wound vacuum therapy (6% vs. 15%, respectively; P Transverse groin incisions for femoral artery exposure may offer a lower risk of wound complications for open procedures as compared to a longitudinal incision

  17. Recent advances in femtosecond laser-assisted cataract surgery

    Directory of Open Access Journals (Sweden)

    Zhao-Jie Chu

    2013-07-01

    Full Text Available Perfect vision and fewer complications is our goal in cataract surgery, femtosecond laser-assisted cataract surgery hold the promise. Applications of femtosecond laser technology for capsulotomy, nuclear fragmentation and corneal incision in cataract surgery bring a new level of accuracy, reproducibility and predictability over the current cataract surgery. The femtosecond laser produces capsulotomies that are more precise, accurate, reproducible, and stronger than those created with the conventional manual technique, and further helps maintain proper positioning of the IOL. Femtosecond laser in nuclear fragmentation lead to a lower effective phacoemulsification time, and the corneal incision is more stable. But currently there are some complications and a clear learning curve associated with the use of femtosecond lasers for cataract surgery. The long-term safety and visual outcomes still need further investigation.

  18. Does Carbon Dioxide Predict Temperature?

    OpenAIRE

    Mytty, Tuukka

    2013-01-01

    Does carbon dioxide predict temperature? No it does not, in the time period of 1880-2004 with the carbon dioxide and temperature data used in this thesis. According to the Inter Governmental Panel on Climate Change(IPCC) carbon dioxide is the most important factor in raising the global temperature. Therefore, it is reasonable to assume that carbon dioxide truly predicts temperature. Because this paper uses observational data it has to be kept in mind that no causality interpretation can be ma...

  19. Excimer laser beam delivery systems for medical applications

    Science.gov (United States)

    Kubo, Uichi; Hashishin, Yuichi; Okada, Kazuyuki; Tanaka, Hiroyuki

    1993-05-01

    We have been doing the basic experiments of UV laser beams and biotissue interaction with both KrF and XeCl lasers. However, the conventional optical fiber can not be available for power UV beams. So we have been investigating about UV power beam delivery systems. These experiments carry on with the same elements doped quartz fibers and the hollow tube. The doped elements are OH ion, chlorine and fluorine. In our latest work, we have tried ArF excimer laser and biotissue interactions, and the beam delivery experiments. From our experimental results, we found that the ArF laser beam has high incision ability for hard biotissue. For example, in the case of the cow's bone incision, the incision depth by ArF laser was ca.15 times of KrF laser. Therefore, ArF laser would be expected to harden biotissue therapy as non-thermal method. However, its beam delivery is difficult to work in this time. We will develop ArF laser beam delivery systems.

  20. Carbon Dioxide Sensor Technology.

    Science.gov (United States)

    1983-04-01

    second gas permeable membrane separates a compartment containing the non-aqueous " solvent dimethylsulfoxide , ( DMSO ), from the aqueous solution...compartment. In DMSO carbon dioxide can be irreversibly reduced electrochemically to * non-interfering products...current due to its reduction in the DMSO solution is proportional to the partial pressure of CO2 in the gas phase. Overall, the linear response and

  1. Carbon dioxide sensor

    Science.gov (United States)

    Dutta, Prabir K [Worthington, OH; Lee, Inhee [Columbus, OH; Akbar, Sheikh A [Hilliard, OH

    2011-11-15

    The present invention generally relates to carbon dioxide (CO.sub.2) sensors. In one embodiment, the present invention relates to a carbon dioxide (CO.sub.2) sensor that incorporates lithium phosphate (Li.sub.3PO.sub.4) as an electrolyte and sensing electrode comprising a combination of lithium carbonate (Li.sub.2CO.sub.3) and barium carbonate (BaCO.sub.3). In another embodiment, the present invention relates to a carbon dioxide (CO.sub.2) sensor has a reduced sensitivity to humidity due to a sensing electrode with a layered structure of lithium carbonate and barium carbonate. In still another embodiment, the present invention relates to a method of producing carbon dioxide (CO.sub.2) sensors having lithium phosphate (Li.sub.3PO.sub.4) as an electrolyte and sensing electrode comprising a combination of lithium carbonate (Li.sub.2CO.sub.3) and barium carbonate (BaCO.sub.3).

  2. Balancing atmospheric carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Goreau, T.J. (Discovery Bay Marine Laboratory, Univ. of the West Indies (JM))

    1990-01-01

    Rising carbon dioxide and global temperatures are causing increasing worldwide concern, and pressure towards an international law of the atmosphere is rapidly escalating, yet widespread misconceptions about the greenhouse effect's inevitability, time scale, and causes have inhibited effective consensus and action. Observations from Antarctic ice cores, Amazonian rain forests, and Carribean coral reefs suggest that the biological effects of climate change may be more severe than climate models predict. Efforts to limit emissions from fossil-fuel combustion alone are incapable of stabilizing levels of carbon dioxide in the atmosphere. Stabilizing atmospheric carbon dioxide requires coupled measures to balance sources and sinks of the gas, and will only be viable with large-scale investments in increased sustainable productivity on degraded tropical soils, and in long-term research on renewable energy and biomass product development in the developing countries. A mechanism is outlined which directly links fossil-fuel combustion sources of carbon dioxide to removal via increasing biotic productivity and storage. A preliminary cost-benefit analysis suggests that such measures are very affordable, costing far less than inaction. (With 88 refs.).

  3. Balancing atmospheric carbon dioxide

    Energy Technology Data Exchange (ETDEWEB)

    Goreau, T J [Discovery Bay Marine Laboratory, Univ. of the West Indies (JM)

    1990-01-01

    Rising carbon dioxide and global temperatures are causing increasing worldwide concern, and pressure towards an international law of the atmosphere is rapidly escalating, yet widespread misconceptions about the greenhouse effect's inevitability, time scale, and causes have inhibited effective consensus and action. Observations from Antarctic ice cores, Amazonian rain forests, and Carribean coral reefs suggest that the biological effects of climate change may be more severe than climate models predict. Efforts to limit emissions from fossil-fuel combustion alone are incapable of stabilizing levels of carbon dioxide in the atmosphere. Stabilizing atmospheric carbon dioxide requires coupled measures to balance sources and sinks of the gas, and will only be viable with large-scale investments in increased sustainable productivity on degraded tropical soils, and in long-term research on renewable energy and biomass product development in the developing countries. A mechanism is outlined which directly links fossil-fuel combustion sources of carbon dioxide to removal via increasing biotic productivity and storage. A preliminary cost-benefit analysis suggests that such measures are very affordable, costing far less than inaction. (With 88 refs.).

  4. Phacoemulsification versus small incision cataract surgery in patients with uveitis

    Directory of Open Access Journals (Sweden)

    Rahul Bhargava

    2015-10-01

    Full Text Available AIM: To compare the safety and efficacy of phacoemulsification and small incision cataract surgery (SICS in patients with uveitic cataract.METHODS:In aprospective, randomized multi-centric study, consecutive patients with uveitic cataract were randomized to receive phacoemulsification or manual SICS by either of two surgeons well versed with both the techniques. A minimum inflammation free period of 3mo (defined as less than 5 cells per high power field in anterior chamber was a pre-requisite for eligibility for surgery. Superior scleral tunnel incisions were used for both techniques. Improvement in visual acuity post-operatively was the primary outcome measure and the rate of post-operative complications and surgical time were secondary outcome measures, respectively. Means of groups were compared using t-tests. One way analysis of variance (ANOVA was used when there were more than two groups. Chi-square tests were used for proportions. Kaplan Meyer survival analysis was done and means for survival time was estimated at 95% confidence interval (CI. A P value of <0.05 was considered statistically significant.RESULTS:One hundred and twenty-six of 139 patients (90.6% completed the 6-month follow-up. Seven patients were lost in follow up and another six excluded due to either follow-up less than six months (n=1 or inability implant an intraocular lens (IOL because of insufficient capsular support following posterior capsule rupture (n=5. There was significant improvement in vision after both the procedures (paired t-test; P<0.001. On first postoperative day, uncorrected distance visual acuity (UDVA was 20/63 or better in 31 (47% patients in Phaco group and 26 (43.3% patients in SICS group (P=0.384. The mean surgically induced astigmatism (SIA was 0.86±0.34 dioptres (D in the phacoemulsification group and 1.16±0.28 D in SICS group. The difference between the groups was significant (t-test, P=0.002. At 6mo, corrected distance visual acuity (CDVA

  5. Laser-assisted skin closure at 1.32 microns: the use of a software-driven medical laser system

    Science.gov (United States)

    Dew, Douglas K.; Hsu, Tung M.; Hsu, Long S.; Halpern, Steven J.; Michaels, Charles E.

    1991-06-01

    This study investigated the use of a computerized 1 .3 micron Nd:YAG laser to seal approximated wound edges in pig skin. The medical laser system used was the DLS Type 1 , 1 .32 micron Nd:YAG laser (Laser Surgery Software, Inc.). The purpose of this study was to evaluate the effectiveness of laser assisted skin closure using the DLS YAG laser in a large animal model. Effectiveness was judged on the basis of wound dehiscence, infection, unusual healing result and consistency of results. Comparative cosmetic result was also evaluated. In this study, the DLS YAG laser was used to close scalpel-induced, full-thickness wounds. The pig model was chosen for its many integumentary similarities to man. Controls included scalpel-induced wounds closed using suture, staple and some with norepair. After adequate anesthesia was achieved, the dorsum of Yucutan pigs (approximately 75- 100 pounds) each was clipped with animal hair clippers from the shoulder area to the hind legs. The area was then shaved with a razor blade, avoiding any inadvertent cuts or abrasions of the skin. The dorsum was divided into four rows of four parallel incisions made by a #15 scalpel blade. Full-thickness incisions, 9 cm long, were placed over the dorsum of the pigs and then closed either with one loosely approximating Prolene" suture (the "no repair' group), multiple interrupted 6-0 nylon sutures, staples or laser. The experimental tissue sealing group consisted of 1 69 laser assisted closures on 1 3 pigs. Sutured control wounds were closed with 6-0 nylon, full thickness, simple, interrupted sutures. Eight sutures were placed 1 cm apart along the 9 cm incision. Stapled control wounds were approximated using two evenly spaced 3-0 VicryP' sub-dermal sutures and the dermis closed using Proximate' skin staples. Eight staples were placed 1 cm apart along the 9 cm incision. The no-repair incisions were grossly approximated using a single 2-0 Prolene full thickness, simple, interrupted suture located at the

  6. Single incision laparoscopic cholecystectomy using the one-incision three-trocar technique with all straight instruments: how I do it?

    Institute of Scientific and Technical Information of China (English)

    Hongyi Cui

    2011-01-01

    Single incision laparoscopic surgery (SILS) is a novel minimally invasive surgical technique that is gaining popularity around the world.One of the most commonly performed procedures is single incision laparoscopic cholecystectomy (SILC).Most reported techniques utilize special purpose-made access port and articulating instruments,rendering the procedure costly and difficult to learn.This article provides a stepwise description of SILC technique using all straight instruments without the need for a special port.It aims to shorten the learning curve for surgeons wishing to adopt a safe and cost-effective SILC technique to their practice.

  7. Cutting and skin-ablative properties of pulsed mid-infrared laser surgery.

    Science.gov (United States)

    Kaufmann, R; Hartmann, A; Hibst, R

    1994-02-01

    Pulsed mid-infrared lasers allow a precise removal of soft tissues with only minimal thermal damage. To study the potential dermatosurgical usefulness of currently available systems at different wavelengths (2010-nm Thulium:YAG laser, 2100-nm Holmium:YAG laser, 2790-nm Erbium:YSGG laser, and 2940-nm Erbium:YAG laser) in vivo on pig skin. Immediate effects and wound healing of superficial laser-abrasions and incisions were compared with those of identical control lesions produced by dermabrasion, scalpel incisions, or laser surgery performed by a 1060-nm Nd:YAG and a 1060-nm CO2 laser (continuous and superpulsed mode). Best efficiency and least thermal injury was found for the pulsed Erbium:YAG laser, leading to ablative and incisional lesions comparable to those obtained by dermabrasion or superficial scalpel incisions, respectively. In contrast to other mid-infrared lasers tested, the 2940-nm Erbium:YAG laser thus provides a potential instrument for future applications in skin surgery, especially when aiming at a careful ablative removal of delicate superficial lesions with maximum sparing of adjacent tissue structures. However, in the purely incisional application mode pulsed mid-infrared lasers, though of potential usefulness in microsurgical indications (eg, surgery of the cornea), do not offer a suggestive alternative to simple scalpel surgery of the skin.

  8. Comparison of Radiofrequency and Electrocautery With Conventional Scalpel Incisions.

    Science.gov (United States)

    Hasar, Zafer Burak; Ozmeric, Nurdan; Ozdemir, Burcu; Gökmenoğlu, Ceren; Baris, Emre; Altan, Gökçen; Kahraman, Sevil

    2016-11-01

    The disadvantages of conventional scalpels, including insufficient control of bleeding, prompted us to search for new alternative methods such as electrosurgery and radiosurgery. In this study, the conventional scalpel was compared with radiosurgery and electrosurgery for wound healing with assessment of lateral heat production, inflammation, and instrument performance. Incisions were made in the palatal mucosa of 42 Wistar rats using a scalpel, electrocautery instrument, or radiofrequency instrument. Postoperative hemostasis, tissue coagulation, and tissue sticking were measured, and pain evaluation through weight loss was recorded. Gingival biopsy specimens from the surgical area were obtained at the time of surgery and 2, 4, 7, and 14 days postoperatively and were evaluated immunohistochemically for inducible nitric oxide synthase and heat shock protein 70. Kruskal-Wallis, 1-way analysis of variance, and Mann-Whitney U tests were used for statistical evaluation. The rats in the electrosurgery and radiosurgery groups had aggressively greater weight loss when compared with the scalpel group in the first 7 days. Hemostasis was better in the electrocautery group, tissue coagulation was greater in the radiofrequency group (P < .001), and tissue sticking was lesser in the scalpel group (P < .001) compared with the other groups. Inducible nitric oxide synthase expression and heat shock protein 70 expression were similar in all 3 groups. Electrosurgery performed better regarding hemostasis, whereas a scalpel was superior in terms of tissue sticking and tissue coagulation. Radiosurgery was superior regarding hemostasis when compared with a conventional scalpel, but it was not as successful as electrosurgery. Copyright © 2016. Published by Elsevier Inc.

  9. Kualitas Pengeringan Kayu Mahoni pada Berbagai Variasi Kerapatan Incising dengan Dua Skedul Pengeringan Suhu tinggi

    Directory of Open Access Journals (Sweden)

    Tomy Listyanto

    2016-11-01

    Full Text Available Tujuan dari penelitian ini adalah untuk mengetahui pengaruh interaksi variasi kerapatan incising dan dua skedul pengeringan terhadap kecepatan dan cacat-cacat pengeringan kayu mahoni, serta mengetahui pengaruh variasi kerapatan incising terhadap kekuatan lengkung statik kayu mahoni yang telah dikeringkan. Tiga pohon mahoni (Swietenia mahagony berdiameter 300-350 mm ditebang dan selanjutnya dibelah dan dibuat menjadi balok dengan ukuran 60 mm × 100 mm dengan panjang 500 mm untuk dijadikan sampel pengeringan. Di antara masing-masing bagian tersebut, dibuat sampel ukuran 20 mm × 20 mm × 25 mm, yang digunakan untuk penentu kadar air awal dan distribusinya. Sampel pengeringan selanjutnya dibagi menjadi 5 variasi kerapatan incising, yaitu 0 lubang/m2 (tanpa incising, 1000 lubang/m2, 2000 lubang/m2, 3000 lubang/m2, dan 4000 lubang/m2. Setiap variasi kerapatan incising selanjutnya akan dikeringkan dengan 2 skedul pengeringan, yaitu suhu pengeringan 100°C sampai tercapai kadar air akhir 12% dan suhu 60°C pada 8 jam pertama dan selanjutnya dilanjutkan 100°C, sampai tercapai kadar air akhir 12%. Paramater yang diamati adalah kecepatan pengeringan, cacat retak permukaan, dan distribusi kadar air akhir. Hasil analisis menunjukkan bahwa kerapatan incising 3000-4000 lubang/m2 memberikan pengaruh yang cukup nyata di dalam mempercepat proses pengeringan dan distribusi kadar air akhir. Skedul pengeringan dan variasi kerapatan incising tidak berpengaruh pada retak permukaan. Pra perlakuan incising sampai batas 4000 lubang/m2 ini dapat diterapkan untuk mempercepat proses pengeringan dengan penurunan nilai modulus elastisitas dan modulus patah yang tidak berbeda nyata. Kata kunci: incising, pengeringan suhu tinggi, mahoni, lengkung statik, skedul pengeringan   Drying Quality of Mahoni Wood in Various Incising Densities and Two High Temperature-Drying Schedules Abstract The aims of this research were to investigate the effects of interaction

  10. Relaxation incisions of venomous snake "Japanese mamushi" bites to the hand

    Directory of Open Access Journals (Sweden)

    Sugamata A

    2011-12-01

    Full Text Available Akira Sugamata, Naoki Yoshizawa, Takahiro OkadaDepartment of Plastic and Reconstructive Surgery, Tokyo Medical University Hachioji Medical Center, Tokyo, JapanAbstract: Gloydius blomhoffii, commonly known as Japanese mamushi, is a venomous viper species found widely in Japan. The most frequently bitten regions are the fingers and toes, and severe swelling causes compression of peripheral arteries and/or compartment syndrome of the extremities. We experienced four cases of mamushi bites to the hand, and undertook relaxation incision in the hands of three of these patients. As a result, the patients who underwent relaxation incision did not show any skin necrosis or permanent sensory disturbance in the affected fingers. Relaxation incision can be useful to not only decompress subcutaneous and compartment pressure of the hand, but also to wash out the venom from the bitten region by improving venous and lymphatic drainage.Keywords: mamushi, snakebite, viper, relaxation incision

  11. Treatment for incarcerated indirect hernia with "Cross-Internal Ring" inguinal oblique incision in children.

    Science.gov (United States)

    Yan, Xue-Qiang; Yang, Jun; Zheng, Nan-Nan; Kuang, Hou-Fang; Duan, Xu-Fei; Bian, Hong-Qiang

    2017-01-01

    This study aims to evaluate the utility of the "Cross-Internal Ring" inguinal oblique incision for the surgical treatment of incarcerated indirect hernia (IIH) complicated with severe abdominal distension. Patients of IIH complicated with severe abdominal distension were reviewed retrospectively. All patients received operation through the "Cross-Internal Ring" inguinal oblique incision. There were totally 13 patients were included, male to female ratio was 9-4. The time for patients to resume oral feeding varying from 2 to 5 days after operation, no complications include delayed intestinal perforation, intra-abdominal abscess, and incision infection happened. Average postoperative hospital stay was 5.2 days. All cases were followed up for 6-18 months. No recurrence or iatrogenic cryptorchidism happened. "Cross-Internal Ring" inguinal oblique incision is a simple, safe, and reliable surgical method to treat pediatric IIH complicated with severe abdominal distension.

  12. Treatment for incarcerated indirect hernia with “Cross-Internal Ring” inguinal oblique incision in children

    Directory of Open Access Journals (Sweden)

    Xue-Qiang Yan

    2017-01-01

    Full Text Available Background: This study aims to evaluate the utility of the “Cross-Internal Ring” inguinal oblique incision for the surgical treatment of incarcerated indirect hernia (IIH complicated with severe abdominal distension. Materials and Methods: Patients of IIH complicated with severe abdominal distension were reviewed retrospectively. All patients received operation through the “Cross-Internal Ring” inguinal oblique incision. Results: There were totally 13 patients were included, male to female ratio was 9-4. The time for patients to resume oral feeding varying from 2 to 5 days after operation, no complications include delayed intestinal perforation, intra-abdominal abscess, and incision infection happened. Average postoperative hospital stay was 5.2 days. All cases were followed up for 6–18 months. No recurrence or iatrogenic cryptorchidism happened. Conclusion: “Cross-Internal Ring” inguinal oblique incision is a simple, safe, and reliable surgical method to treat pediatric IIH complicated with severe abdominal distension.

  13. Cochlear implantation with Pulsar Med El: a novel small incision technique.

    Science.gov (United States)

    Cuda, D

    2009-04-01

    Although still widely implanted, Pulsar Med-El is rarely considered for small incision approach. Overall, 30 teen-age and adult patients were operated upon with a novel small incision (4-5 cm). Full insertion of the electrode array was achieved in all cases. No major intra-operative complications occurred. At follow-up, no flap-related complications and no migration of the receiver-stimulator were observed in the "device suture" (14 patients) or "no device suture" groups (16 patients). All patients are full-time users of the device. In conclusion, a small incision for the Pulsar Med-El cochlear implant is feasible, safe and reproducible. Ligature fixation of the device is not critical with this operation. Also with this device, in adult and teen-age patients, it is, therefore, possible to retain several typical advantages of small incision approaches.

  14. Laser tumor treatment in oral and maxillofacial surgery

    Science.gov (United States)

    Neukam, F. W.; Stelzle, F.

    Cancer treatment is an integral part of oral and maxillofacial surgery. Oral cancer in particular is a highly prevalent neoplasm. Standard treatment for most of the tumors is radical surgery combined with stage-based neo-/adjuvant therapy. Laser surgery has become a reliable treatment option for oral cancer as well as for precancerous lesions. Widely used lasers in oral and maxillofacial tumor surgery are the CO2 laser, the Er:YAG laser, the Nd:YAG laser and the KTM laser. The use of lasers in tumor surgery has several advantages: remote application, precise cutting, hemostasis, low cicatrization, reduced postoperative pain and swelling, can be combined with endoscopic, microscopic and robotic surgery. However, laser surgery has some major drawbacks: In contrast to conventional incisions with scalpels, the surgeon gets no feedback during laser ablation. There is no depth sensation and no tissue specificity with a laser incision, increasing the risk of iatrogenic damage to nerves and major blood vessels. Future prospects may solve these problems by means of an optical feedback mechanism that provides a tissue-specific laser ablation. First attempts have been made to perform remote optical tissue differentiation. Additionally, real time optical tumor detection during laser surgery would allow for a very precise and straight forward cancer resection, enhancing organ preservation and hence the quality of life for patients with cancer in the head and neck region.

  15. Efficient, space-based, PM 100W thulium fiber laser for pumping Q-switched 2μm Ho:YLF for global winds and carbon dioxide lidar

    Science.gov (United States)

    Engin, Doruk; Mathason, Brian; Storm, Mark

    2017-08-01

    Global wind measurements are critically needed to improve and extend NOAA weather forecasting that impacts U.S. economic activity such as agriculture crop production, as well as hurricane forecasting, flooding, and FEMA disaster planning.1 NASA and the 2007 National Research Council (NRC) Earth Science Decadal Study have also identified global wind measurements as critical for global change research. NASA has conducted aircraft-based wind lidar measurements using 2 um Ho:YLF lasers, which has shown that robust wind measurements can be made. Fibertek designed and demonstrated a high-efficiency, 100 W average power continuous wave (CW) 1940 nm thulium (Tm)- doped fiber laser bread-board system meeting all requirements for a NASA Earth Science spaceflight 2 μm Ho:YLF pump laser. Our preliminary design shows that it is possible to package the laser for high-reliability spaceflight operation in an ultra-compact 2″x8″x14″ size and weight <8.5 lbs. A spaceflight 100 W polarization maintaining (PM) Tm laser provides a path to space for a pulsed, Q-switched 2 μm Ho:YLF laser with 30-80 mJ/pulse range at 100-200 Hz repletion rates.

  16. Evaluation of a new disposable silicon limbal relaxing incision knife by experienced users

    OpenAIRE

    Parvu Valentin; Dugue Geoffrey; Albanese John; Bajart Ann M; Lee Edwin

    2009-01-01

    Abstract Background Previous research has suggested that the silicon BD Atomic Edge™ knife has superior performance characteristics when compared to a metal knife and performance similar to diamond knife when making various incisions. This study was designed to determine whether a silicon accurate depth knife has equivalent performance characteristics when compared to a diamond limbal relaxing incision (LRI) knife and superior performance characteristics when compared to a steel accurate dept...

  17. Aorta-atria-septum combined incision for aortic valve re-replacement

    Science.gov (United States)

    Xu, Yiwei; Ye, Xiaofeng; Li, Zhaolong

    2018-01-01

    This case report illustrates a patient who underwent supra-annular mechanical aortic valve replacement then suffered from prosthesis dysfunction, increasing pressure gradient with aortic valve. She was successfully underwent aortic valve re-replacement, sub-annular pannus removing and aortic annulus enlargement procedures through combined cardiac incision passing through aortic root, right atrium (RA), and upper atrial septum. This incision provides optimal visual operative field and simplifies dissection. PMID:29850170

  18. Type of incision does not predict abdominal wall outcome after emergency surgery for colonic anastomotic leakage

    DEFF Research Database (Denmark)

    Jensen, Kristian Kiim; Oma, Erling; Harling, Henrik

    2017-01-01

    for anastomotic leakage were included with a median follow-up of 5.4 years. Incisional hernia occurred in 41 of 227 (15.3%) patients undergoing midline incision compared with 14 of 81 (14.7%) following transverse incision, P = 1.00. After adjusting for confounders, there was no association between the type...... not predict abdominal wall outcome after emergency surgery for colonic anastomotic leakage....

  19. Carbon dioxide dangers demonstration model

    Science.gov (United States)

    Venezky, Dina; Wessells, Stephen

    2010-01-01

    Carbon dioxide is a dangerous volcanic gas. When carbon dioxide seeps from the ground, it normally mixes with the air and dissipates rapidly. However, because carbon dioxide gas is heavier than air, it can collect in snowbanks, depressions, and poorly ventilated enclosures posing a potential danger to people and other living things. In this experiment we show how carbon dioxide gas displaces oxygen as it collects in low-lying areas. When carbon dioxide, created by mixing vinegar and baking soda, is added to a bowl with candles of different heights, the flames are extinguished as if by magic.

  20. Evaluation of a new disposable silicon limbal relaxing incision knife by experienced users.

    Science.gov (United States)

    Albanese, John; Dugue, Geoffrey; Parvu, Valentin; Bajart, Ann M; Lee, Edwin

    2009-12-21

    Previous research has suggested that the silicon BD Atomic Edge knife has superior performance characteristics when compared to a metal knife and performance similar to diamond knife when making various incisions. This study was designed to determine whether a silicon accurate depth knife has equivalent performance characteristics when compared to a diamond limbal relaxing incision (LRI) knife and superior performance characteristics when compared to a steel accurate depth knife when creating limbal relaxing incision. Sixty-five ophthalmic surgeons with limbal relaxing incision experience created limbal relaxing incisions in ex-vivo porcine eyes with silicon and steel accurate depth knives and diamond LRI knives. The ophthalmic surgeons rated multiple performance characteristics of the knives on Visual Analog Scales. The observed differences between the silicon knife and diamond knife were found to be insignificant. The mean ratio between the performance of the silicon knife and the diamond knife was shown to be greater than 90% (with 95% confidence). The silicon knife's mean performance was significantly higher than the performance of the steel knife for all characteristics. (p-value knife was found to be equivalent in performance to the diamond LRI knife and superior to the steel accurate depth knife when making limbal relaxing incisions in ex vivo porcine eyes. Disposable silicon LRI knives may be an alternative to diamond LRI knives.

  1. Evaluation of a new disposable silicon limbal relaxing incision knife by experienced users

    Directory of Open Access Journals (Sweden)

    Parvu Valentin

    2009-12-01

    Full Text Available Abstract Background Previous research has suggested that the silicon BD Atomic Edge™ knife has superior performance characteristics when compared to a metal knife and performance similar to diamond knife when making various incisions. This study was designed to determine whether a silicon accurate depth knife has equivalent performance characteristics when compared to a diamond limbal relaxing incision (LRI knife and superior performance characteristics when compared to a steel accurate depth knife when creating limbal relaxing incision. Methods Sixty-five ophthalmic surgeons with limbal relaxing incision experience created limbal relaxing incisions in ex-vivo porcine eyes with silicon and steel accurate depth knives and diamond LRI knives. The ophthalmic surgeons rated multiple performance characteristics of the knives on Visual Analog Scales. Results The observed differences between the silicon knife and diamond knife were found to be insignificant. The mean ratio between the performance of the silicon knife and the diamond knife was shown to be greater than 90% (with 95% confidence. The silicon knife's mean performance was significantly higher than the performance of the steel knife for all characteristics. (p-value Conclusions For experienced users, the silicon accurate depth knife was found to be equivalent in performance to the diamond LRI knife and superior to the steel accurate depth knife when making limbal relaxing incisions in ex vivo porcine eyes. Disposable silicon LRI knives may be an alternative to diamond LRI knives.

  2. Watershed-scale modeling of streamflow change in incised montane meadows

    Science.gov (United States)

    Essaid, Hedeff I.; Hill, Barry R.

    2014-01-01

    Land use practices have caused stream channel incision and water table decline in many montane meadows of the Western United States. Incision changes the magnitude and timing of streamflow in water supply source watersheds, a concern to resource managers and downstream water users. The hydrology of montane meadows under natural and incised conditions was investigated using watershed simulation for a range of hydrologic conditions. The results illustrate the interdependence between: watershed and meadow hydrology; bedrock and meadow aquifers; and surface and groundwater flow through the meadow for the modeled scenarios. During the wet season, stream incision resulted in less overland flow and interflow and more meadow recharge causing a net decrease in streamflow and increase in groundwater storage relative to natural meadow conditions. During the dry season, incision resulted in less meadow evapotranspiration and more groundwater discharge to the stream causing a net increase in streamflow and a decrease in groundwater storage relative to natural meadow conditions. In general, for a given meadow setting, the magnitude of change in summer streamflow and long-term change in watershed groundwater storage due to incision will depend on the combined effect of: reduced evapotranspiration in the eroded meadow; induced groundwater recharge; replenishment of dry season groundwater storage depletion in meadow and bedrock aquifers by precipitation during wet years; and groundwater storage depletion that is not replenished by precipitation during wet years.

  3. A new approach to model CW CO2 laser using rate equations

    Indian Academy of Sciences (India)

    2016-11-11

    Nov 11, 2016 ... Abstract. Two popular methods to analyse the operation of CW CO2 lasers use the temperature model and ... Grouping of the vibration levels helped in restrict- ..... [10] D C Tyte, Carbon dioxide lasers, in: Advances in quan-.

  4. Histologic effects of resurfacing lasers.

    Science.gov (United States)

    Freedman, Joshua R; Greene, Ryan M; Green, Jeremy B

    2014-02-01

    By utilizing resurfacing lasers, physicians can significantly improve the appearance of sun-damaged skin, scars, and more. The carbon dioxide and erbium:yttrium-aluminum-garnet lasers were the first ablative resurfacing lasers to offer impressive results although these earlier treatments were associated with significant downtime. Later, nonablative resurfacing lasers such as the neodymium:yttrium-aluminum-garnet laser proved effective, after a series of treatments with less downtime, but with more modest results. The theory of fractional photothermolysis has revolutionized resurfacing laser technology by increasing the safety profile of the devices while delivering clinical efficacy. A review of the histologic and molecular consequences of the resurfacing laser-tissue interaction allows for a better understanding of the devices and their clinical effects. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  5. The origin and significance of sinuosity along incising bedrock rivers

    Science.gov (United States)

    Barbour, Jonathan Ross

    Landscapes evolve through processes acting at the earth's surface in response to tectonics and climate. Rivers that cut into bedrock are particularly important since they set the local baselevel and communicate changes in boundary conditions across the landscape through erosion and deposition; the pace of topographic evolution depends on both the rate of change of the boundary conditions and the speed of the bedrock channel network response. Much of the work so far has considered the effects of tectonically-controlled changes in slope and climatically-controlled changes in discharges to the rate of channel bed erosion while considering bank erosion, if active at all, to be of at best secondary importance to landscape evolution. Sprinkled throughout the literature of the past century are studies that have recognized lateral activity along incising rivers, but conflicting interpretations have left many unanswered questions about how to identify and measure horizontal erosion, what drives it, what effect it has on the landscape, and how it responds to climate and tectonics. In this thesis, I begin to answer some of these questions by focusing on bedrock river sinuosity and its evolution through horizontal erosion of the channel banks. An analysis of synoptic scale topography and climatology of the islands of eastern Asia reveals a quantitative signature of storm frequency in a regional measure of mountain river sinuosity. This is partly explained through a study of the hydro- and morphodynamics of a rapidly evolving bedrock river in Taiwan which shows how the erosive forces vary along a river to influence the spatiotemporal distribution of downcutting, sidecutting, and sediment transport. Through these analyses, I also present evidence that suggests that the relative frequency of erosive events is far more important than the absolute magnitude of extreme events in setting the erosion rate, and I show that the horizontal erosion of bedrock rivers is an important

  6. A Precise 6 Ma Start Date for Fluvial Incision of the Northeastern Colorado Plateau Canyonlands

    Science.gov (United States)

    Thomson, S. N.; Soreghan, G. S.; Reiners, P. W.; Peyton, S. L.; Murray, K. E.

    2015-12-01

    Outstanding questions regarding late Cenozoic Colorado Plateau landscape evolution include: (1) the relative roles of isostatic rebound as result Colorado River incision versus longer-term geodynamic processes in driving overall rock uplift of the plateau; and (2) whether incision was triggered by river integration or by a change in deep-seated mantle lithosphere dynamics. A key to answering these questions is to date more precisely the onset of incision to refine previous estimates of between 6 and 10 Ma. We present new low-temperature thermochronologic results from bedrock and deep borehole samples in the northeastern Colorado Plateau to show that rapid river incision began here at 6 Ma (5.93±0.66 Ma) with incision rates increasing from 15-50 m/Myr to 160-200 m/Myr. The onset time is constrained independently by both inverse time-temperature modeling and by the break-in-slope in fission track age-elevation relationships. This new time constraint has several important implications. First, the coincidence in time with 5.97-5.3 Ma integration of the lower Colorado River through the Grand Canyon to the Gulf of California strongly favors downstream river integration triggering carving of the canyonlands of the upper Colorado River system. Second, it implies integration of the entire Colorado River system in less than 2 million years. Third, rock uplift of the plateau driven by the flexural isostatic response to river incision is restricted to just the last 6 Ma, as is associated increased sediment budget. Fourth, incision starting at 6 Ma means that previous estimates of upper Colorado River incision rates based on 10-12 Ma basalt datum levels are too low. This also changes the dependency of measured time interval on incision rate from a non-steady-state negative power-law dependence (exponent of -0.24) to a near steady-state dependence (exponent of 0.07) meaning that long-term upper Colorado river incision rates can provide a reliable proxy for rock uplift rates.

  7. Methanation of Carbon Dioxide

    OpenAIRE

    Goodman, Daniel Jacob

    2013-01-01

    The emission of greenhouse gases into the atmosphere has been linked to global warming. Carbon dioxide's (CO2) one of the most abundant greenhouse gases. Natural gas, mainly methane, is the cleanest fossil fuel for electricity production helping meet the United States ever growing energy needs. The methanation of CO2 has the potential to address both of these problems if a catalyst can be developed that meets the activity, economic and environmental requirements to industrialize the process. ...

  8. CARBON DIOXIDE FIXATION.

    Energy Technology Data Exchange (ETDEWEB)

    FUJITA,E.

    2000-01-12

    Solar carbon dioxide fixation offers the possibility of a renewable source of chemicals and fuels in the future. Its realization rests on future advances in the efficiency of solar energy collection and development of suitable catalysts for CO{sub 2} conversion. Recent achievements in the efficiency of solar energy conversion and in catalysis suggest that this approach holds a great deal of promise for contributing to future needs for fuels and chemicals.

  9. Production of uranium dioxide

    International Nuclear Information System (INIS)

    Hart, J.E.; Shuck, D.L.; Lyon, W.L.

    1977-01-01

    A continuous, four stage fluidized bed process for converting uranium hexafluoride (UF 6 ) to ceramic-grade uranium dioxide (UO 2 ) powder suitable for use in the manufacture of fuel pellets for nuclear reactors is disclosed. The process comprises the steps of first reacting UF 6 with steam in a first fluidized bed, preferably at about 550 0 C, to form solid intermediate reaction products UO 2 F 2 , U 3 O 8 and an off-gas including hydrogen fluoride (HF). The solid intermediate reaction products are conveyed to a second fluidized bed reactor at which the mol fraction of HF is controlled at low levels in order to prevent the formation of uranium tetrafluoride (UF 4 ). The first intermediate reaction products are reacted in the second fluidized bed with steam and hydrogen at a temperature of about 630 0 C. The second intermediate reaction product including uranium dioxide (UO 2 ) is conveyed to a third fluidized bed reactor and reacted with additional steam and hydrogen at a temperature of about 650 0 C producing a reaction product consisting essentially of uranium dioxide having an oxygen-uranium ratio of about 2 and a low residual fluoride content. This product is then conveyed to a fourth fluidized bed wherein a mixture of air and preheated nitrogen is introduced in order to further reduce the fluoride content of the UO 2 and increase the oxygen-uranium ratio to about 2.25

  10. Measurement of the concentration ratio for 13N and 12N isotopes at atmospheric pressure by carbon dioxide absorption of diode laser radiation at ∼2 μm

    International Nuclear Information System (INIS)

    Mironchuk, E S; Nikolaev, I V; Ochkin, Vladimir N; Rodionova, S S; Spiridonov, Maksim V; Tskhai, Sergei N

    2009-01-01

    The ratio of 12 NO 2 and 13 CO 2 concentrations in the human exhaled air is measured by the method of diode laser spectroscopy using a three-channel optical scheme and multipass cell. Unlike the previous measurements in the spectral range of ∼4.3 μm with a resolved rotational structure at low pressure of selected samples, the present measurements are performed in the range of ∼2 μm, in which weaker absorption bands of CO 2 reside. In this case, it is possible to employ lasers and photodetectors operating at room temperature. The thorough simulation of the spectrum with collisional broadening of lines and employment of regression analysis allow one to take measurements at atmospheric pressure with the accuracy of ∼0.04%, which satisfies the requirements to medical diagnostics of ulcers. (laser spectroscopy)

  11. Surgically induced astigmatism after 3.0 mm temporal and nasal clear corneal incisions in bilateral cataract surgery

    Directory of Open Access Journals (Sweden)

    Je Hwan Yoon

    2013-01-01

    Full Text Available Aims: To compare the corneal refractive changes induced after 3.0 mm temporal and nasal corneal incisions in bilateral cataract surgery. Materials and Methods: This prospective study comprised a consecutive case series of 60 eyes from 30 patients with bilateral phacoemulsification that were implanted with a 6.0 mm foldable intraocular lens through a 3.0 mm horizontal clear corneal incision (temporal in the right eyes, nasal in the left eyes. The outcome measures were surgically induced astigmatism (SIA and uncorrected visual acuity (UCVA 1 and 3 months, post-operatively. Results: At 1 month, the mean SIA was 0.81 diopter (D for the temporal incisions and 0.92 D for nasal incisions (P = 0.139. At 3 months, the mean SIA were 0.53 D for temporal incisions and 0.62 D for nasal incisions (P = 0.309. The UCVA was similar in the 2 incision groups before surgery, and at 1 and 3 months post-operatively. Conclusion: After bilateral cataract surgery using 3.0 mm temporal and nasal horizontal corneal incisions, the induced corneal astigmatic change was similar in both incision groups. Especially in Asian eyes, both temporal and nasal incisions (3.0 mm or less would be favorable for astigmatism-neutral cataract surgery.

  12. Laser resurfacing pearls.

    Science.gov (United States)

    Shah, Sonia; Alam, Murad

    2012-08-01

    Ablative skin resurfacing using the carbon dioxide laser was long considered the gold standard for treatment of photoaging, acne scars, and rhytids. However, conventional full-face carbon dioxide resurfacing is associated with significant risk of side effects and a prolonged postoperative recovery period. Fractional resurfacing has recently revolutionized laser surgery by offering close to comparable results with minimal side effects and a more rapid recovery. Although fractional devices have grown in popularity, and have essentially replaced traditional resurfacing, fractional resurfacing can still be a challenging modality to control precisely due to hardware variations across comparable devices, the range of settings that can be used, and patient-specific considerations. Certain precautions and rules of thumb can reduce the risk associated with fractional resurfacing, and increase the likelihood of a good outcome.

  13. Lasers '89

    International Nuclear Information System (INIS)

    Harris, D.G.; Shay, T.M.

    1990-01-01

    This book covers the following topics: XUV, X-Ray and Gamma-Ray Lasers, excimer lasers, chemical lasers, nuclear pumped lasers, high power gas lasers, solid state lasers, laser spectroscopy. The paper presented include: Development of KrF lasers for fusion and Nuclear driven solid-state lasers

  14. Does pilonidal abscess heal quicker with off-midline incision and drainage?

    Science.gov (United States)

    Webb, P M; Wysocki, A P

    2011-06-01

    No clinical trials have been done to guide the surgeon in the optimal technique of draining a pilonidal abscess. The aim of our study was to investigate whether the location of the incision influences wound healing. Electronic records from the surgical database at our 200-bed district general hospital were reviewed for operative technique (midline vs. lateral) for patients who underwent incision and drainage for acute pilonidal abscess between January 2003 and February 2010. These patients were admitted from the Emergency Department with a pilonidal abscess, underwent operative drainage, and returned for follow-up. The main outcome measure was wound healing time. Two hundred and forty-three pilonidal abscesses were drained, 134 with a lateral and 74 with a midline incision. All patients underwent simple longitudinal incision. No patient underwent de-roofing, marsupialisation, or closure. Forty-eight patients with midline drainage who returned for follow-up were matched for gender, age, and microbiology culture results with patients who underwent lateral drainage. Almost all were drained under general anesthesia with a median postoperative stay of 1 day. The overall length of follow-up was the same in both groups (P = 0.13). Abscesses that did not heal were followed-up for the same period of time irrespective of incision type (P = 0.48). Abscesses that healed after midline incision took approximately 3 weeks longer than those drained via a lateral incision (P = 0.02). Our study has limitations since it was a retrospective study that did not capture patients whose abscess drained spontaneously or were drained in the emergency department. Pilonidal abscess should be drained away from the midline.

  15. A study of incisive canal using a cone beam computed tomography

    International Nuclear Information System (INIS)

    Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Sang Rae

    2004-01-01

    To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70 kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. The mean length of incisive canal was 15.87 mm ± 2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm ± 0.76 and 3.89 mm ± 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3 ± 6.96 and 117.45 ± 7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r 0.258). This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  16. A study of incisive canal using a cone beam computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Sang Rae [Kyunghee University College of Medicine, Seoul (Korea, Republic of)

    2004-03-15

    To investigate the anatomical structure of the incisive canal radiographically by a cone beam computed tomography. 38 persons (male 26, female 12) were chosen to take images of maxillary anterior region in dental CT mode using a cone beam computed tomography. The tube voltage were 65, 67, and 70 kVp, the tube current was 7 mA, and the exposure time was 13.3 seconds. The FH plane of each person was parallel to the floor. The images were analysed on the CRT display. The mean length of incisive canal was 15.87 mm {+-} 2.92. The mean diameter at the side of palate and nasal fossa were 3.49 mm {+-} 0.76 and 3.89 mm {+-} 1.06, respectively. In the cross-sectional shape of incisive canal, 50% were round, 34.2% were ovoid, and 15.8% were lobulated. 87% of incisive canal at the side of nasal fossa have one canal, 10.4% have two canals, and 2.6% have three canals, but these canals were merged into one canal in the middle portion of palate. The mean angles of the long axis of incisive canal and central incisor to the FH plane were 110.3 {+-} 6.96 and 117.45 {+-} 7.41, respectively. The angles of the long axis of incisive canal and central incisor to the FH plane were least correlated (r 0.258). This experiment suggests that a cone beam computed radiography will be helpful in surgery or implantation on the maxillary incisive area.

  17. The cohesive energy of uranium dioxide and thorium dioxide

    International Nuclear Information System (INIS)

    Childs, B.G.

    1958-08-01

    Theoretical values have been calculated of the heats of formation of uranium dioxide and thorium dioxide on the assumption that the atomic binding forces in these solids are predominantly ionic in character. The good agreement found between the theoretical and observed values shows that the ionic model may, with care, be used in calculating the energies of defects in the uranium and thorium dioxide crystal structures. (author)

  18. Is it possible to prevent morbidity on post cardiovascular surgery applying low level laser therapy?

    Science.gov (United States)

    Pinto, Nathali C.; Baptista, Ivany Machado d. C.; Pereira, Mara Helena C.; Serrão, Nelson F.; Pomerantzeff, Pablo M. A.; Chavantes, Maria Cristina

    2014-03-01

    Background and Objective: Complications following cardiovascular surgery incision are common in mediastinitis and wound dehiscence form, a 47% mortality rate remaining. Low Level Laser Therapy (LLLT) has been employed mainly to its effectiveness analgesic and anti-inflammatory actions, aiding the tissue repair process. The aim of this study was to evaluate infrared LLLT onto surgical incision in patients submitted to cardiovascular surgery. Materials and Methods: 40 patients were divided in two groups: Placebo Group (G1) - conventional therapy + "Laser pointer" and Laser Group (G2) - conventional therapy + Infrared Laser irradiation on surgical incision. Diode Laser was employed, C.W. mode, around the surgical wound bed, on immediate Post Operative (PO), 1st PO and 3rd PO with the following parameters: wavelength (λ): 830nm, P=35mW, E=0,75J. Results: G2 didn't present any complication and 5% of patients in G1 developed incision dehiscence and infection. On 7thPO, still a large amount of G1 patients showed pain and unquestionable inflammatory signs surrounding the surgical wound, when compared to G2. Besides, hospital stay in Laser Group was 2 times shorter than in Placebo Group (p-value=0.001). Conclusion: Infrared Laser denoted to be safe and exceptionally valuable tools in preventing morbidities on post cardiovascular surgeries.

  19. In vivo comparison of near infrared lasers for skin welding.

    Science.gov (United States)

    Tabakoğlu, Haşim Ozgür; Gülsoy, Murat

    2010-05-01

    The skin closure abilities of near infrared lasers and suturing were compared by histological examination and mechanical tensile tests during a 21-day healing period. One-centimeter incisions on the dorsal skin of Wistar rats were treated by one of the closing techniques: (a) soldering, using an 809 nm diode laser (0.5 W, 5 s) with 25% bovine serum albumin (BSA) and 2.5 mg/ml indocyanine green (ICG); (b) direct welding with a 980 nm diode laser (0.5 W, 5 s); (c) direct welding with a 1,070 nm fiber laser (0.5 W, 5 s); (d) suturing. Six spots (79.61 J/cm(2) for each spot) were applied through the incisions. Healing was inspected on the 1st, 4th, 7th, 14th, and 21st post-operative days. The closure index (CI), thermally altered area (TAA), granulation area (GA) and epidermal thickness (ET) were determined by histological examination. Tensile tests were performed at a 5 mm/min crosshead speed up to the first opening along the incision. Immediate superficial closure with high CI values was found for the laser-irradiated incisions at the early phase of recovery. Clear welds without thermal damage were observed for the group irradiated at 1,070 nm. For the sutured group, the incisions remained unclosed for the first day, and openings through the incision were observed. At the end of the 21-day recovery period, no differences between experimental groups were observed in terms of the CI, GA and ET values. However, the tensile strength of the groups irradiated at 980 nm and 1,070 nm was found to be higher than that of the sutured incisions. The laser welding techniques were found to be reliable in terms of immediate and mechanically strong closure compared with suturing. Of them, 1,070 nm laser welding yielded noticeably stronger bonds, with minimal scarring at the end of the 21-days of recovery.

  20. Surface hardening using cw CO2 laser: laser heat treatment, modelation, and experimental work

    Science.gov (United States)

    Muniz, German; Alum, Jorge

    1996-02-01

    In the present work are given the results of the application of laser metal surface hardening techniques using a cw carbon dioxide laser as an energy source on steel 65 G. The laser heat treatment results are presented theoretically and experimentally. Continuous wave carbon dioxide laser of 0.6, 0.3, and 0.4 kW were used. A physical model for the descriptions of the thermophysical laser metal interactions process is given and a numerical algorithm is used to solve this problem by means of the LHT code. The results are compared with the corresponding experimental ones and a very good agreement is observed. The LHT code is able to do predictions of transformation hardening by laser heating. These results will be completed with other ones concerning laser alloying and cladding presented in a second paper.

  1. Climate-sensitive feedbacks between hillslope processes and fluvial erosion in sediment-driven incision models

    Science.gov (United States)

    Skov, Daniel S.; Egholm, David L.

    2016-04-01

    Surface erosion and sediment production seem to have accelerated globally as climate cooled in the Late Cenozoic, [Molnar, P. 2004, Herman et al 2013]. Glaciers emerged in many high mountain ranges during the Quaternary, and glaciation therefore represents a likely explanation for faster erosion in such places. Still, observations and measurements point to increases in erosion rates also in landscapes where erosion is driven mainly by fluvial processes [Lease and Ehlers (2013), Reusser (2004)]. Flume experiments and fieldwork have shown that rates of incision are to a large degree controlled by the sediment load of streams [e.g. Sklar and Dietrich (2001), Beer and Turowski (2015)]. This realization led to the formulation of sediment-flux dependent incision models [Sklar and Dietrich (2004)]. The sediment-flux dependence links incision in the channels to hillslope processes that supply sediment to the channels. The rates of weathering and soil transport on the hillslopes are processes that are likely to respond to changing temperatures, e.g. because of vegetation changes or the occurrence of frost. In this study, we perform computational landscape evolution experiments, where the coupling between fluvial incision and hillslope processes is accounted for by coupling a sediment-flux-dependent model for fluvial incision to a climate-dependent model for weathering and hillslope sediment transport. The computational experiments first of all demonstrate a strong positive feedback between channel and hillslope processes. In general, faster weathering leads to higher rates of channel incision, which further increases the weathering rates, mainly because of hillslope steepening. Slower weathering leads to the opposite result. The experiments also demonstrate, however, that the feedbacks vary significantly between different parts of a drainage network. For example, increasing hillslope sediment production may accelerate incision in the upper parts of the catchment, while at

  2. Molybdenum dioxide-molybdenite roasting

    International Nuclear Information System (INIS)

    Sabacky, B.J.; Hepworth, M.T.

    1984-01-01

    A process is disclosed for roasting molybdenite concentrates directly to molybdenum dioxide. The process comprises establishing a roasting zone having a temperature of about 700 0 C. to about 800 0 C., introducing into the roasting zone particulate molybdenum dioxide and molybdenite in a weight ratio of at least about 2:1 along with an oxygen-containing gas in amount sufficient to oxidize the sulfur content of the molybdenite to molybdenum dioxide

  3. Force modeling for incisions into various tissues with MRF haptic master

    Science.gov (United States)

    Kim, Pyunghwa; Kim, Soomin; Park, Young-Dai; Choi, Seung-Bok

    2016-03-01

    This study proposes a new model to predict the reaction force that occurs in incisions during robot-assisted minimally invasive surgery. The reaction force is fed back to the manipulator by a magneto-rheological fluid (MRF) haptic master, which is featured by a bi-directional clutch actuator. The reaction force feedback provides similar sensations to laparotomy that cannot be provided by a conventional master for surgery. This advantage shortens the training period for robot-assisted minimally invasive surgery and can improve the accuracy of operations. The reaction force modeling of incisions can be utilized in a surgical simulator that provides a virtual reaction force. In this work, in order to model the reaction force during incisions, the energy aspect of the incision process is adopted and analyzed. Each mode of the incision process is classified by the tendency of the energy change, and modeled for realistic real-time application. The reaction force model uses actual reaction force information with three types of actual tissues: hard tissue, medium tissue, and soft tissue. This modeled force is realized by the MRF haptic master through an algorithm based on the position and velocity of a scalpel using two different control methods: an open-loop algorithm and a closed-loop algorithm. The reaction forces obtained from the proposed model are compared with a desired force in time domain.

  4. Panoramic radiographs underestimate extensions of the anterior loop and mandibular incisive canal

    Energy Technology Data Exchange (ETDEWEB)

    De Brito, Ana Caroline Ramos; Nejaim, Yuri; De Freitas, Deborah Queiroz [Dept. of Oral Diagnosis, Division of Oral Radiology, Piracicaba Dental School, University of Campinas, Sao Paulo (Brazil); De Oliveira Santos, Christiano [Dept. of Stomatology, Public Oral Health and Forensic Dentistry, School of Dentistry of Ribeirao Preto, University of Sao Paulo, Sao Paulo (Brazil)

    2016-09-15

    The purpose of this study was to detect the anterior loop of the mental nerve and the mandibular incisive canal in panoramic radiographs (PAN) and cone-beam computed tomography (CBCT) images, as well as to determine the anterior/mesial extension of these structures in panoramic and cross-sectional reconstructions using PAN and CBCT images. Images (both PAN and CBCT) from 90 patients were evaluated by 2 independent observers. Detection of the anterior loop and the incisive canal were compared between PAN and CBCT. The anterior/mesial extension of these structures was compared between PAN and both cross-sectional and panoramic CBCT reconstructions. In CBCT, the anterior loop and the incisive canal were observed in 7.7% and 24.4% of the hemimandibles, respectively. In PAN, the anterior loop and the incisive canal were detected in 15% and 5.5% of cases, respectively. PAN presented more difficulties in the visualization of structures. The anterior/mesial extensions ranged from 0.0 mm to 19.0 mm on CBCT. PAN underestimated the measurements by approximately 2.0 mm. CBCT appears to be a more reliable imaging modality than PAN for preoperative workups of the anterior mandible. Individual variations in the anterior/mesial extensions of the anterior loop of the mental nerve and the mandibular incisive canal mean that is not prudent to rely on a general safe zone for implant placement or bone surgery in the interforaminal region.

  5. Microincision versus small-incision coaxial cataract surgery using different power modes for hard nuclear cataract.

    Science.gov (United States)

    Kim, Eun Chul; Byun, Yong Soo; Kim, Man Soo

    2011-10-01

    To compare the efficacy of microincision and small-incision coaxial phacoemulsification in treating hard cataracts using different ultrasound power modes. Department of Ophthalmology, Seoul St. Mary's Hospital, College of Medicine, Catholic University of Korea, Seoul, Korea. Randomized clinical trial. Eyes with hard cataract were randomized to have an initial incision of 1.80 mm, 2.20 mm, or 2.75 mm. The eyes in each group were equally randomized to treatment with burst, pulse, or continuous mode. Ultrasound time (UST), mean cumulative dissipated energy (CDE), corrected distance visual acuity (CDVA), surgically induced corneal astigmatism, incisional and central corneal thickness (CCT), and endothelial cell counts were evaluated. The study enrolled 180 eyes, 60 in each group. Two months postoperatively, there were no statistically significant differences in UST, CDE, CDVA, CCT, or percentage endothelial cell loss between the 3 incision groups. The 2.75 mm incision induced more astigmatism at 2 months and less incisional corneal edema at 1 week than the 1.80 mm or 2.20 mm incision (Phard cataract. The intraoperative energy use and ocular damage was less with the pulse and burst modes than with the continuous mode. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  6. Single incision laparoscopic pancreas resection for pancreatic metastasis of renal cell carcinoma.

    Science.gov (United States)

    Barbaros, Umut; Sümer, Aziz; Demirel, Tugrul; Karakullukçu, Nazlı; Batman, Burçin; Içscan, Yalın; Sarıçam, Gülay; Serin, Kürçsat; Loh, Wei-Liang; Dinççağ, Ahmet; Mercan, Selçuk

    2010-01-01

    Transumbilical single incision laparoscopic surgery (SILS) offers excellent cosmetic results and may be associated with decreased postoperative pain, reduced need for analgesia, and thus accelerated recovery. Herein, we report the first transumbilical single incision laparoscopic pancreatectomy case in a patient who had renal cell cancer metastasis on her pancreatic corpus and tail. A 59-year-old female who had metastatic lesions on her pancreas underwent laparoscopic subtotal pancreatectomy through a 2-cm umbilical incision. Single incision pancreatectomy was performed with a special port (SILS port) and articulated equipment. The procedure lasted 330 minutes. Estimated blood loss was 100mL. No perioperative complications occurred. The patient was discharged on the seventh postoperative day with a low-volume (20mL/day) pancreatic fistula that ceased spontaneously. Pathology result of the specimen was renal cell cancer metastases. This is the first reported SILS pancreatectomy case, demonstrating that even advanced surgical procedures can be performed using the SILS technique in well-experienced centers. Transumbilical single incision laparoscopic pancreatectomy is feasible and can be performed safely in experienced centers. SILS may improve cosmetic results and allow accelerated recovery for patients even with malignancy requiring advanced laparoscopic interventions.

  7. Panoramic radiographs underestimate extensions of the anterior loop and mandibular incisive canal

    International Nuclear Information System (INIS)

    De Brito, Ana Caroline Ramos; Nejaim, Yuri; De Freitas, Deborah Queiroz; De Oliveira Santos, Christiano

    2016-01-01

    The purpose of this study was to detect the anterior loop of the mental nerve and the mandibular incisive canal in panoramic radiographs (PAN) and cone-beam computed tomography (CBCT) images, as well as to determine the anterior/mesial extension of these structures in panoramic and cross-sectional reconstructions using PAN and CBCT images. Images (both PAN and CBCT) from 90 patients were evaluated by 2 independent observers. Detection of the anterior loop and the incisive canal were compared between PAN and CBCT. The anterior/mesial extension of these structures was compared between PAN and both cross-sectional and panoramic CBCT reconstructions. In CBCT, the anterior loop and the incisive canal were observed in 7.7% and 24.4% of the hemimandibles, respectively. In PAN, the anterior loop and the incisive canal were detected in 15% and 5.5% of cases, respectively. PAN presented more difficulties in the visualization of structures. The anterior/mesial extensions ranged from 0.0 mm to 19.0 mm on CBCT. PAN underestimated the measurements by approximately 2.0 mm. CBCT appears to be a more reliable imaging modality than PAN for preoperative workups of the anterior mandible. Individual variations in the anterior/mesial extensions of the anterior loop of the mental nerve and the mandibular incisive canal mean that is not prudent to rely on a general safe zone for implant placement or bone surgery in the interforaminal region

  8. Incision and stress regulation in borderline personality disorder: neurobiological mechanisms of self-injurious behaviour.

    Science.gov (United States)

    Reitz, Sarah; Kluetsch, Rosemarie; Niedtfeld, Inga; Knorz, Teresa; Lis, Stefanie; Paret, Christian; Kirsch, Peter; Meyer-Lindenberg, Andreas; Treede, Rolf-Detlef; Baumgärtner, Ulf; Bohus, Martin; Schmahl, Christian

    2015-08-01

    Patients with borderline personality disorder frequently show non-suicidal self-injury (NSSI). In these patients, NSSI often serves to reduce high levels of stress. Investigation of neurobiological mechanisms of NSSI in borderline personality disorder. In total, 21 women with borderline personality disorder and 17 healthy controls underwent a stress induction, followed by either an incision into the forearm or a sham treatment. Afterwards participants underwent resting-state functional magnetic resonance imaging while aversive tension, heart rate and heart rate variability were assessed. We found a significant influence of incision on subjective and objective stress levels with a stronger decrease of aversive tension in the borderline personality disorder group following incision than sham. Amygdala activity decreased more and functional connectivity with superior frontal gyrus normalised after incision in the borderline personality disorder group. Decreased stress levels and amygdala activity after incision support the assumption of an influence of NSSI on emotion regulation in individuals with borderline personality disorder and aids in understanding why these patients use self-inflicted pain to reduce inner tension. © The Royal College of Psychiatrists 2015.

  9. Circumareolar incision-subdermal tunneling dissection for excision of multiple breast fibroadenomata

    Directory of Open Access Journals (Sweden)

    S O Agodirin

    2017-01-01

    Full Text Available Excision of multiple fibroadenomas (MF in separate breast quadrants presents difficulties of number and location of incision(s and extent of tissue dissection and may be associated with more complications and poorer cosmetic outcome. This is a report of excision of MF in multiple quadrants of the breast using a modification of subcutaneous dissection technique dubbed the circumareolar incision and subdermal tunneling (CAST dissection. After exposure of the superficial fascia with circumareolar incision, subdermal cone-wise dissection was made to allow mobilization of the segment bearing the lump(s. The lump(s were enucleated and removed. MF were removed from four breasts in three young unmarried females. The first patient had multiple adenomas removed from three quadrants of both breasts: 14 on the right and six on the left. The second patient had excision of three lumps in three separate quadrants, and the third patient had excision of two lumps in two separate quadrants. All patients had edema and bruising. One breast had wound infection and dehiscence. There were no skin necrosis, no nipple loss, and no breast distortion. All ensuing scars were camouflaged. CAST dissection was used for excision of MF in multiple quadrants of the breast with preservation of excellent cosmetic outcome of a single circumareolar incision.

  10. Uptake of gallium-67 citrate in clean surgical incisions after colorectal surgery

    International Nuclear Information System (INIS)

    Lin Wanyu; Wang Shyhjen; Tsai Shihchuan; Chao Tehsin

    2001-01-01

    Non-specific accumulation of gallium-67 citrate (gallium) in uncomplicated surgical incisions is not uncommon. It is important to know the normal pattern of gallium uptake at surgical incision sites in order to properly interpret the gallium scan when investigating possible wound infection in patients who have undergone abdominal surgery. We studied 42 patients without wound infection after colorectal surgery and performed gallium scans within 40 days after surgery. Patients were divided into three groups according to the interval between the operation and the scan. In group A (26 patients) gallium scan was performed within 7 days after surgery, in group B (8 patients) between 8 and 14 days after surgery, and in group C (8 patients) between 15 and 40 days after surgery. Our data showed that in group A, 61.5% had gallium accumulation at the surgical incision site. In group B, 50% had accumulation of gallium at the surgical incision site, while in group C only one patient (12.5%) showed gallium uptake. It is concluded that the incidence of increased gallium uptake at clean surgical incision sites is high after colorectal surgery. Nuclear medicine physicians should bear in mind the high incidence of non-specific gallium uptake at such sites during the interpretation of possible wound infection in patients after colorectal surgery. (orig.)

  11. Force modeling for incisions into various tissues with MRF haptic master

    International Nuclear Information System (INIS)

    Kim, Pyunghwa; Kim, Soomin; Park, Young-Dai; Choi, Seung-Bok

    2016-01-01

    This study proposes a new model to predict the reaction force that occurs in incisions during robot-assisted minimally invasive surgery. The reaction force is fed back to the manipulator by a magneto-rheological fluid (MRF) haptic master, which is featured by a bi-directional clutch actuator. The reaction force feedback provides similar sensations to laparotomy that cannot be provided by a conventional master for surgery. This advantage shortens the training period for robot-assisted minimally invasive surgery and can improve the accuracy of operations. The reaction force modeling of incisions can be utilized in a surgical simulator that provides a virtual reaction force. In this work, in order to model the reaction force during incisions, the energy aspect of the incision process is adopted and analyzed. Each mode of the incision process is classified by the tendency of the energy change, and modeled for realistic real-time application. The reaction force model uses actual reaction force information with three types of actual tissues: hard tissue, medium tissue, and soft tissue. This modeled force is realized by the MRF haptic master through an algorithm based on the position and velocity of a scalpel using two different control methods: an open-loop algorithm and a closed-loop algorithm. The reaction forces obtained from the proposed model are compared with a desired force in time domain. (paper)

  12. Laser-assisted fibrinogen bonding of umbilical vein grafts.

    Science.gov (United States)

    Oz, M C; Williams, M R; Souza, J E; Dardik, H; Treat, M R; Bass, L S; Nowygrod, R

    1993-06-01

    Despite success with autologous tissue welding, laser welding of synthetic vascular prostheses has not been possible. The graft material appears inert and fails to allow the collagen breakdown and electrostatic bonding that results in tissue welding. To develop a laser welding system for graft material, we repaired glutaraldehyde-tanned human umbilical cord vein graft incisions using laser-assisted fibrinogen bonding (LAFB) technology. Modified umbilical vein graft was incised transversely (1.2 cm). Incisions were repaired using sutures, laser energy alone, or LAFB. For LAFB, indocyanine green dye was mixed with human fibrinogen and the compound applied with forceps onto the weld site prior to exposure to 808 nm diode laser energy (power density 4.8 W/cm 2). Bursting pressures for sutured repairs (126.6 +/- 23.4 mm Hg) were similar to LAFB anastomoses (111.6 +/- 55.0 mm Hg). No evidence of collateral thermal injury to the graft material was noted. In vivo evaluation of umbilical graft bonding with canine arteries demonstrates that LAFB can reliably reinforce sutured anastomoses. The described system for bonding graft material with laser exposed fibrinogen may allow creation or reinforcement of vascular anastomoses in procedures where use of autologous tissue is not feasible.

  13. Steady incision of Grand Canyon at the million year timeframe: a case for mantle-driven differential uplift

    Science.gov (United States)

    Crow, Ryan S.; Karl Karlstrom,; Laura Crossey,; Richard Young,; Michael Ort,; Yemane Asmerom,; Victor Polyak,; Andrew Darling,

    2014-01-01

    The Grand Canyon region provides an excellent laboratory to examine the interplay between river incision, magmatism, and the geomorphic and tectonic processes that shape landscapes. Here we apply U-series, Ar–Ar, and cosmogenic burial dating of river terraces to examine spatial variations in incision rates along the 445 km length of the Colorado River through Grand Canyon. We also analyze strath terrace sequences that extend to heights of several hundred meters above the river, and integrate these with speleothem constrained maximum incision rates in several reaches to examine any temporal incision variations at the million-year time frame. This new high-resolution geochronology shows temporally steady long-term incision in any given reach of Grand Canyon but significant variations along its length from 160 m/Ma in the east to 101 m/Ma in the west. Spatial and temporal patterns of incision, and the long timescale of steady incision rule out models where geomorphic controls such as climate oscillations, bedrock strength, sediment load effects, or isostatic response to differential denudation are the first order drivers of canyon incision. The incision pattern is best explained by a model of Neogene and ongoing epeirogenic uplift due to an eastward propagating zone of increased upper mantle buoyancy that we infer from propagation of Neogene basaltic volcanism and a strong lateral gradient in modern upper mantle seismic structure.

  14. Process for sequestering carbon dioxide and sulfur dioxide

    Science.gov (United States)

    Maroto-Valer, M Mercedes [State College, PA; Zhang, Yinzhi [State College, PA; Kuchta, Matthew E [State College, PA; Andresen, John M [State College, PA; Fauth, Dan J [Pittsburgh, PA

    2009-10-20

    A process for sequestering carbon dioxide, which includes reacting a silicate based material with an acid to form a suspension, and combining the suspension with carbon dioxide to create active carbonation of the silicate-based material, and thereafter producing a metal salt, silica and regenerating the acid in the liquid phase of the suspension.

  15. Ultraviolet-laser ablation of skin

    Energy Technology Data Exchange (ETDEWEB)

    Lane, R.J.; Linsker, R.; Wynne, J.J.; Torres, A.; Geronemus, R.G.

    1985-05-01

    The authors report on the use of pulsed ultraviolet-laser irradiation at 193 nm from an argon-fluoride laser and at 248 nm from a krypton-fluoride laser to ablate skin. In vitro, both wavelengths performed comparably, removing tissue precisely and cleanly, and leaving minimal thermal damage to the surrounding tissue. In vivo, the 193-nm laser radiation failed to remove tissue after bleeding began. The 248-nm radiation, however, continued to remove tissue despite bleeding and left a clean incision with only minimal thermal damage. The krypton-fluoride excimer laser beam at 248 nm, which should be deliverable through a quartz optical fiber, has great potential as a surgical instrument.

  16. Oral subcutaneous midline leiomyomatous hamartoma presenting as congenital incisive papilla overgrowth in a toddler

    Directory of Open Access Journals (Sweden)

    Ashish Loomba

    2017-01-01

    Full Text Available Congenital soft-tissue tumors of oral cavity are mostly hyperplastic and benign in nature. This article presents an unusual case of congenital subcutaneous hamartoma of incisive papilla in a 2-year-old female child causing feeding and breathing difficulty. Total excisional biopsy was done under local anesthesia. Histopathology of tissue in reticulin-stained slide showed the presence of immature muscle fibers whereas Masson's trichrome stain revealed collagen fibers and smooth muscles confirming the diagnosis of oral midline subcutaneous smooth muscle (leiomyomatous hamartoma of incisive papilla. It is important for dental professionals to be aware of this oral lesion present from birth mimicking overgrowth of incisive papilla, by its presentation, differential diagnosis, histopathology, and management.

  17. Incision of the heart during meat inspection of fattening pigs - A risk-profile approach.

    Science.gov (United States)

    Leps, J; Fries, R

    2009-01-01

    Meat inspection in the EU is based on Regulation (EC) 854/2004. Accordingly a risk based meat inspection should be implemented. In this paper, the incision of the heart in pig meat inspection is discussed with respect to efficacy. The incision especially can reveal the presence of endocarditis. Here, Erysipelothrixrhusiopathiae (E. rhusiopathiae) and/or Streptococcussuis (S. suis) are of particular concern. Both agents are regarded to be zoonotic agents. There is some evidence for infection of humans via an alimentary pathway. Hence, the occurrence of E. rhusiopathiae and S. suis is a concern of public health (PH) as well as veterinary public health (VPH). However, other measures, including on-farm disease prevention and diagnosis, seem to be more important for food safety. It is concluded that the incision and inspection of the heart is not justifiable with respect to PH aspects.

  18. Applications of lasers and electro-optics

    International Nuclear Information System (INIS)

    Tan, B.C.; Low, K.S.; Chen, Y.H.; Harith bin Ahmad; Tou, T.Y.

    1994-01-01

    Supported by the IRPA Programme on Laser Technology and Applications, many types of lasers have been designed, constructed and applied in various areas of science, medicine and industries. Amongst these lasers constructed were high power carbon dioxide lasers, rare gas halide excimer lasers, solid state Neodymium-YAG lasers, nitrogen lasers, flashlamp pumped dye lasers and nitrogen and excimer laser pumped dye lasers. These lasers and the associated electro-optics system, some with computer controlled, are designed and developed for the following areas of applications: 1. Industrial applications of high power carbon dioxide lasers for making of i.c. components and other materials processing purposes. Prototype operational systems have been developed. 2. Medical applications of lasers for cancer treatment using the technique of photodynamic therapy. A new and more effective treatment protocol has been proposed. 3. Agricultural applications of lasers in palm oil and palm fruit-fluorescence diagnostic studies. Fruit ripeness signature has been developed and palm oil oxidation level were investigated. 4. Development of atmospheric pollution monitoring systems using laser lidar techniques. Laboratory scale systems were developed. 5. Other applications of lasers including laser holographic and interferometric methods for the non destructive testing of materials. The activities of the group (from 1988-1990) have resulted in the submission of a patent for a laser device, publication of many research paper sin local and overseas journals and conference proceedings, completion of 1 Ph.D. dissertation and 6 M. Phil theses. Currently (1991), a total of 3 Ph.D., 6 M. Phil research programmes are involved in this research and development programme

  19. Impact of selective pituitary gland incision or resection on hormonal function after adenoma or cyst resection.

    Science.gov (United States)

    Barkhoudarian, Garni; Cutler, Aaron R; Yost, Sam; Lobo, Bjorn; Eisenberg, Amalia; Kelly, Daniel F

    2015-12-01

    With the resection of pituitary lesions, the anterior pituitary gland often obstructs transsphenoidal access to the lesion. In such cases, a gland incision and/or partial gland resection may be required to obtain adequate exposure. We investigate this technique and determine the associated risk of post-operative hypopituitarism. All patients who underwent surgical resection of a pituitary adenoma or Rathke cleft cyst (RCC) between July 2007 and January 2013 were analyzed for pre- and post-operative hormone function. The cohort of patients with gland incision/resection were compared to a case-matched control cohort of pituitary surgery patients. Total hypophysectomy patients were excluded from outcome analysis. Of 372 operations over this period, an anterior pituitary gland incision or partial gland resection was performed in 79 cases (21.2 %). These include 53 gland incisions, 12 partial hemi-hypophysectomies and 14 resections of thinned/attenuated anterior gland. Diagnoses included 64 adenomas and 15 RCCs. New permanent hypopituitarism occurred in three patients (3.8 %), including permanent DI (3) and growth hormone deficiency (1). There was no significant difference in the rate of worsening gland dysfunction nor gain of function. Compared to a control cohort, there was a significantly lower incidence of transient DI (1.25 vs. 11.1 %, p = 0.009) but no significant difference in permanent DI (3.8 vs. 4.0 %) in the gland incision group. Selective gland incisions and gland resections were performed in over 20 % of our cases. This technique appears to minimize traction on compressed normal pituitary gland during removal of large lesions and facilitates better visualization and removal of cysts, microadenomas and macroadenomas.

  20. The effect of kidney morcellation on operative time, incision complications, and postoperative analgesia after laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Affonso H. Camargo

    2006-06-01

    Full Text Available INTRODUCTION: Compare the outcomes between kidney morcellation and two types of open specimen extraction incisions, several covariates need to be taken into consideration that have not yet been studied. MATERIALS AND METHODS: We retrospectively reviewed 153 consecutive patients who underwent laparoscopic nephrectomy at our institution, 107 who underwent specimen morcellation and 46 with intact specimen removal, either those with connected port sites with a muscle-cutting incision and those with a remote, muscle-splitting incision. Operative time, postoperative analgesia requirements, and incisional complications were evaluated using univariate and multivariate analysis, comparing variables such as patient age, gender, body mass index (BMI, laterality, benign versus cancerous renal conditions, estimated blood loss, specimen weight, overall complications, and length of stay. RESULTS: There was no significant difference for operative time between the 2 treatment groups (p = 0.65. Incision related complications occurred in 2 patients (4.4% from the intact specimen group but none in the morcellation group (p = 0.03. Overall narcotic requirement was lower in patients with morcellated (41 mg compared to intact specimen retrieval (66 mg on univariate (p = 0.03 and multivariate analysis (p = 0.049. Upon further stratification, however, there was no significant difference in mean narcotic requirement between the morcellation and muscle-splitting incision subgroup (p = 0.14. CONCLUSION: Morcellation does not extend operative time, and is associated with significantly less postoperative pain compared to intact specimen retrieval overall, although this is not statistically significant if a remote, muscle-splitting incision is made. Morcellation markedly reduces the risk of incisional-related complications.

  1. Cutting electrocautery versus scalpel for surgical incisions: a systematic review and meta-analysis.

    Science.gov (United States)

    Ismail, Ammar; Abushouk, Abdelrahman Ibrahim; Elmaraezy, Ahmed; Menshawy, Amr; Menshawy, Esraa; Ismail, Mahmoud; Samir, Esraa; Khaled, Anas; Zakarya, Hagar; El-Tonoby, Abdelrahman; Ghanem, Esraa

    2017-12-01

    Although cutting electrocautery can be superior to the scalpel in reducing blood loss and incisional time, several reports associated electrocautery with higher rates of wound infection, impaired healing, and worse cosmesis. We performed this systematic review and meta-analysis to compare cutting electrocautery versus scalpel for surgical incisions. We conducted a computerized literature search of five electronic databases and included all published original studies comparing cutting electrocautery and scalpel surgical incisions. Relevant data were extracted from eligible studies and pooled as odds ratios (ORs) or standardized mean difference (SMD) values in a meta-analysis model, using RevMan and Comprehensive Meta-analysis software. Forty-one studies (36 randomized trials, four observational, and one quasirandom study) were included in the pooled analysis (6422 participants). Compared with the scalpel incision, cutting electrocautery resulted in significantly less blood loss (SMD = -1.16, 95% CI [-1.60 to -0.72]), shorter incisional (SMD = -0.63, 95% CI [-0.96 to -0.29]) and operative times (SMD = -0.59, 95% CI [-1.12 to -0.05]), and lower pain scores (SMD = -0.91, 95% CI [-1.27 to -0.55]) with no significant differences in terms of wound infection rates (OR = 0.92, 95% CI [0.74-1.15]) or overall subjective scar score (SMD = -0.49, 95% CI [-1.72 to 0.75]). Surgical incision using electrocautery can be quicker with less blood loss and postoperative pain scores than the scalpel incision. No statistically significant difference was found between both techniques in terms of postoperative wound complications, hospital stay duration, and wound cosmetic characteristics. Therefore, we recommend routine use of cutting electrocautery for surgical incisions. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Carbon dioxide and climate

    Energy Technology Data Exchange (ETDEWEB)

    1990-10-01

    Scientific and public interest in greenhouse gases, climate warming, and global change virtually exploded in 1988. The Department's focused research on atmospheric CO{sub 2} contributed sound and timely scientific information to the many questions produced by the groundswell of interest and concern. Research projects summarized in this document provided the data base that made timely responses possible, and the contributions from participating scientists are genuinely appreciated. In the past year, the core CO{sub 2} research has continued to improve the scientific knowledge needed to project future atmospheric CO{sub 2} concentrations, to estimate climate sensitivity, and to assess the responses of vegetation to rising concentrations of CO{sub 2} and to climate change. The Carbon Dioxide Research Program's goal is to develop sound scientific information for policy formulation and governmental action in response to changes of atmospheric CO{sub 2}. The Program Summary describes projects funded by the Carbon Dioxide Research Program during FY 1990 and gives a brief overview of objectives, organization, and accomplishments.

  3. Incision of the Jezero Crater Outflow Channel by Fluvial Sediment Transport

    Science.gov (United States)

    Holo, S.; Kite, E. S.

    2017-12-01

    Jezero crater, the top candidate landing site for the Mars 2020 rover, once possessed a lake that over-spilled and eroded a large outflow channel into the Eastern rim. The Western deltaic sediments that would be the primary science target of the rover record a history of lake level, which is modulated by the inflow and outflow channels. While formative discharges for the Western delta exist ( 500 m3/s), little work has been done to see if these flows are the same responsible for outflow channel incision. Other models of the Jezero outflow channel incision assume that a single rapid flood (incision timescales of weeks), with unknown initial hydraulic head and no discharge into the lake (e.g. from the inflow channels or the subsurface), incised an open channel with discharge modulated by flow over a weir. We present an alternate model where, due to an instability at the threshold of sediment motion, the incision of the outflow channel occurs in concert with lake filling. In particular, we assume a simplified lake-channel-valley system geometry and that the channel is hydraulically connected to the filling/draining crater lake. Bed load sediment transport and water discharge through the channel are quantified using the Meyer-Peter and Mueller relation and Manning's law respectively. Mass is conserved for both water and sediment as the lake level rises/falls and the channel incises. This model does not resolve backwater effects or concavity in the alluvial system, but it does capture the non-linear feedbacks between lake draining, erosion rate, channel flow rate, and slope relaxation. We identify controls on incision of the outflow channel and estimate the time scale of outflow channel formation through a simple dynamical model. We find that the observed 300m of channel erosion can be reproduced in decades to centuries of progressive bed load as the delta forming flows fill the lake. This corresponds to time scales on the order of or smaller than the time scale

  4. Fingertip replantation using a single volar arteriovenous anastomosis and drainage with a transverse tip incision.

    Science.gov (United States)

    Yabe, T; Muraoka, M; Motomura, H; Ozawa, T

    2001-11-01

    Four cases of fingertip replantation using a single volar arteriovenous anastomosis and drainage with a transverse tip incision are reported. Because of lack of suitable arteries for anastomosis in the amputated finger, in each case a volar radial vein was anastomosed to the proximal digital artery and external drainage was performed through a transverse tip incision. In 3 cases the replanted fingertip survived completely; partial necrosis occurred in 1 case. Because veins are more superficial and larger than arteries, they are more available for anastomosis. The results indicate that this method is a useful alternative in fingertip replantation.

  5. Fractional laser skin resurfacing.

    Science.gov (United States)

    Alexiades-Armenakas, Macrene R; Dover, Jeffrey S; Arndt, Kenneth A

    2012-11-01

    Laser skin resurfacing (LSR) has evolved over the past 2 decades from traditional ablative to fractional nonablative and fractional ablative resurfacing. Traditional ablative LSR was highly effective in reducing rhytides, photoaging, and acne scarring but was associated with significant side effects and complications. In contrast, nonablative LSR was very safe but failed to deliver consistent clinical improvement. Fractional LSR has achieved the middle ground; it combined the efficacy of traditional LSR with the safety of nonablative modalities. The first fractional laser was a nonablative erbium-doped yttrium aluminum garnet (Er:YAG) laser that produced microscopic columns of thermal injury in the epidermis and upper dermis. Heralding an entirely new concept of laser energy delivery, it delivered the laser beam in microarrays. It resulted in microscopic columns of treated tissue and intervening areas of untreated skin, which yielded rapid reepithelialization. Fractional delivery was quickly applied to ablative wavelengths such as carbon dioxide, Er:YAG, and yttrium scandium gallium garnet (2,790 nm), providing more significant clinical outcomes. Adjustable laser parameters, including power, pitch, dwell time, and spot density, allowed for precise determination of percent surface area, affected penetration depth, and clinical recovery time and efficacy. Fractional LSR has been a significant advance to the laser field, striking the balance between safety and efficacy.

  6. Preliminary observation of refractive cataract surgery assisted by femtosecond laser

    Directory of Open Access Journals (Sweden)

    Xiao-Li Wang

    2015-12-01

    Full Text Available AIM:To compare the differences of visual acuity and corneal astigmatism postoperatively between conventional refractive cataract surgery and that assisted by femtosecond laser.METHODS:Sixty patients(60 eyeswith age-related cataract and cornea astigmatism were divided into femtosecond group and conventional group randomly or voluntarily. The flat shaft, steep shaft and diopter of corneal astigmatism in patients in femtosecond group were inputted into the online vector calculators to get the location and width of the incision. Then femtosecond laser was used to make corneal releasing incision, the main and auxiliary incision. Phacoemulsification and aspheric multifocal intraocular lens implantation were undergone. Patients in conventional group received full-thickness relaxing incision by cornea paracentesis knife at the steepest meridian axis during phacoemulsification. Then aspheric multifocal intraocular lenses were implanted. Uncorrected distance visual acuity(UCDVA, uncorrected near visual acuity(UCNVAand cornea astigmatism were observed at 1d,1wk and 1mo postoperative. RESULTS:UCVA of patients in both groups was improved after the surgeries. UCDVA and UCNVA of femtosecond group were higher than those of conventional group, while the cornea astigmatism of femtosecond group was lower than that of conventional group.CONCLUSION:Refractile cataract surgery assisted by femtosecond laser canoffer better visual quality than conventional refractive cataract surgery because of lower cornea astigmatism and better visual acuity.

  7. Lidar detection of carbon dioxide in volcanic plumes

    Science.gov (United States)

    Fiorani, Luca; Santoro, Simone; Parracino, Stefano; Maio, Giovanni; Del Franco, Mario; Aiuppa, Alessandro

    2015-06-01

    Volcanic gases give information on magmatic processes. In particular, anomalous releases of carbon dioxide precede volcanic eruptions. Up to now, this gas has been measured in volcanic plumes with conventional measurements that imply the severe risks of local sampling and can last many hours. For these reasons and for the great advantages of laser sensing, the thorough development of volcanic lidar has been undertaken at the Diagnostics and Metrology Laboratory (UTAPRAD-DIM) of the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA). In fact, lidar profiling allows one to scan remotely volcanic plumes in a fast and continuous way, and with high spatial and temporal resolution. Two differential absorption lidar instruments will be presented in this paper: BILLI (BrIdge voLcanic LIdar), based on injection seeded Nd:YAG laser, double grating dye laser, difference frequency mixing (DFM) and optical parametric amplifier (OPA), and VULLI (VULcamed Lidar), based on injection seeded Nd:YAG laser and optical parametric oscillator (OPO). The first one is funded by the ERC (European Research Council) project BRIDGE and the second one by the ERDF (European Regional Development Fund) project VULCAMED. While VULLI has not yet been tested in a volcanic site, BILLI scanned the gas emitted by Pozzuoli Solfatara (Campi Flegrei volcanic area, Naples, Italy) during a field campaign carried out from 13 to 17 October 2014. Carbon dioxide concentration maps were retrieved remotely in few minutes in the crater area. Lidar measurements were in good agreement with well-established techniques, based on different operating principles. To our knowledge, it is the first time that carbon dioxide in a volcanic plume is retrieved by lidar, representing the first direct measurement of this kind ever performed on an active volcano and showing the high potential of laser remote sensing in geophysical research.

  8. Comparison of the effects of 23-gauge and 25-gauge microincision vitrectomy blade designs on incision architecture

    Directory of Open Access Journals (Sweden)

    Inoue M

    2014-11-01

    Full Text Available Makoto Inoue,1 Dina Joy K Abulon,2 Akito Hirakata1 1Kyorin Eye Center, School of Medicine, Kyorin University, Tokyo, Japan; 2Alcon Research, Ltd., Irvine, CA, USA Purpose: To compare the effects of different 23- and 25-gauge microincision vitrectomy trocar cannula entry systems on incision architecture.Methods: We tested one ridged microvitreoretinal (MVR, one non-ridged MVR, one pointed beveled, and one round-tipped beveled blade (n=10 per blade design per incision type. Each blade’s straight and oblique incision architecture was assessed in a silicone disc simulating the sclera. Wound leakage under pressure and endoscopic observations were conducted on sclerotomy sites of isolated porcine eyes (n=4 per blade design after simulated vitrectomy.Results: Differences in blade design created distinct incision architecture. Incisions were linear with the ridged MVR blade, flattened “M-shaped” with the non-ridged MVR blade, asymmetrical chevron-shaped with the pointed beveled blade, and curved with the round-tipped beveled blade. With the exception of oblique entry incision thickness, both MVR blade designs created thinner incisions than the beveled blades at entry and exit sites. Only the ridged MVR blade created incisions with no leakage. Vitreous incarceration was observed with all trocar cannula systems.Conclusion: Wound closure in porcine eyes was similar with all blades despite differences in incision architecture. Wound leakage occurred at low to moderate infusion pressures with most blades; no wound leakage was observed with ridged MVR blades. Keywords: entry system, incision closure, leakage, pars plana incision, sclerotomy, trocar blade 

  9. Uranium dioxide electrolysis

    Science.gov (United States)

    Willit, James L [Batavia, IL; Ackerman, John P [Prescott, AZ; Williamson, Mark A [Naperville, IL

    2009-12-29

    This is a single stage process for treating spent nuclear fuel from light water reactors. The spent nuclear fuel, uranium oxide, UO.sub.2, is added to a solution of UCl.sub.4 dissolved in molten LiCl. A carbon anode and a metallic cathode is positioned in the molten salt bath. A power source is connected to the electrodes and a voltage greater than or equal to 1.3 volts is applied to the bath. At the anode, the carbon is oxidized to form carbon dioxide and uranium chloride. At the cathode, uranium is electroplated. The uranium chloride at the cathode reacts with more uranium oxide to continue the reaction. The process may also be used with other transuranic oxides and rare earth metal oxides.

  10. Uranium dioxide pellets

    International Nuclear Information System (INIS)

    Zawidzki, T.W.

    1982-01-01

    A process for the preparation of a sintered, high density, large crystal grain size uranium dioxide pellet is described which involves: (i) reacting a uranyl nitrate of formula UO 2 (NO 3 ) 2 .6H 2 O with a sulphur source, at a temperature of from about 300 deg. C to provide a sulphur-containing uranium trioxide; (ii) reacting the thus-obtained modified uranium trioxide with ammonium nitrate to form an insoluble sulphur-containing ammonium uranate; (iii) neutralizing the thus-formed slurry with ammonium hydroxide to precipitate out as an insoluble ammonium uranate the remaining dissolved uranium; (iv) recovering the thus-formed precipitates in a dry state; (v) reducing the dry precipitate to UO 2 , and forming it into 'green' pellets; and (vi) sintering the pellets in a hydrogen atmosphere at an elevated temperature

  11. Forecasting carbon dioxide emissions.

    Science.gov (United States)

    Zhao, Xiaobing; Du, Ding

    2015-09-01

    This study extends the literature on forecasting carbon dioxide (CO2) emissions by applying the reduced-form econometrics approach of Schmalensee et al. (1998) to a more recent sample period, the post-1997 period. Using the post-1997 period is motivated by the observation that the strengthening pace of global climate policy may have been accelerated since 1997. Based on our parameter estimates, we project 25% reduction in CO2 emissions by 2050 according to an economic and population growth scenario that is more consistent with recent global trends. Our forecasts are conservative due to that we do not have sufficient data to fully take into account recent developments in the global economy. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Uranium dioxide calcining apparatus

    International Nuclear Information System (INIS)

    Cole, E.A.; Peterson, R.S.

    1978-01-01

    This invention relates to an improved continuous calcining apparatus for consistently and controllably producing from calcinable reactive solid compounds of uranium, such as ammonium diuranate, uranium dioxide (UO 2 ) having an oxygen to uranium ratio of less than 2.2. The apparatus comprises means at the outlet end of a calciner kiln for receiving hot UO 2 , means for cooling the UO 2 to a temperature of below 100 deg C and conveying the cooled UO 2 to storage or to subsequent UO 2 processing apparatus where it finally comes into contact with air, the means for receiving cooling and conveying being sealed to the outlet end of the calciner and being maintained full of UO 2 and so operable as to exclude atmospheric oxygen from coming into contact with any UO 2 which is at elevated temperatures where it would readily oxidize, without the use of extra hydrogen gas in said means. (author)

  13. Use of the holmium:YAG laser in urology

    Science.gov (United States)

    Mattioli, Stefano

    1997-12-01

    The Holmium-YAG is a versatile laser with multiple soft- tissue applications including tissue incision and vaporization, and pulsed-laser applications such as lithotripsy. At 2140 nanometers, the wavelength is highly absorbed by tissue water. Further, like CO2 laser, the Holmium produces immediate tissue vaporization while minimizing deep thermal damage to surrounding tissues. It is an excellent instrument for endopyelotomy, internal urethrotomy, bladder neck incisions and it can be used to resect the prostate. The Holmium creates an acute TUR defect which gives immediate results like the TURP. More than 50 patients were treated from Jan. 1996 to Jan. 1997 for obstructive symptoms due to benign prostatic hyperplasia, bladder neck stricture, urethral stenosis, and superficial bladder tumors.

  14. Rapid fluvial incision of a late Holocene lava flow: Insights from LiDAR, alluvial stratigraphy, and numerical modeling

    Science.gov (United States)

    Sweeney, Kristin; Roering, Joshua J.

    2016-01-01

    Volcanic eruptions fundamentally alter landscapes, paving over channels, decimating biota, and emplacing fresh, unweathered material. The fluvial incision of blocky lava flows is a geomorphic puzzle. First, high surface permeability and lack of sediment should preclude geomorphically effective surface runoff and dissection. Furthermore, past work has demonstrated the importance of extreme floods in driving incision via column toppling and plucking in columnar basalt, but it is unclear how incision occurs in systems where surface blocks are readily mobile. We examine rapid fluvial incision of the Collier lava flow, an andesitic Holocene lava flow in the High Cascades of Oregon. Since lava flow emplacement ∼1600 yr ago, White Branch Creek has incised bedrock gorges up to 8 m deep into the coherent core of the lava flow and deposited >0.2 km3 of sediment on the lava flow surface. Field observation points to a bimodal discharge regime in the channel, with evidence for both annual snowmelt runoff and outburst floods from Collier glacier, as well as historical evidence of vigorous glacial meltwater. To determine the range of discharge events capable of incision in White Branch Creek, we used a mechanistic model of fluvial abrasion. We show that the observed incision implies that moderate flows are capable of both initiating channel formation and sustaining incision. Our results have implications for the evolution of volcanic systems worldwide, where glaciation and/or mass wasting may accelerate fluvial processes by providing large amounts of sediment to otherwise porous, sediment-starved landscapes.

  15. Comparison of incision and drainage against needle aspiration for the treatment of breast abscess.

    Science.gov (United States)

    Naeem, Muhammad; Rahimnajjad, Muhammad Kazim; Rahimnajjad, Nasir Ali; Ahmed, Qazi Jalaluddin; Fazel, Pyar Ali; Owais, Muhammad

    2012-11-01

    We aim to compare the incision and drainage against ultrasound-guided aspiration for the treatment of breast abscesses. Sixty-four patients were randomly allocated to Group A (incision and drainage) and Group B (needle aspiration). Incision and drainage was done under general, whereas aspiration was done under local anesthesia with antibiotic coverage after the pus sample was taken for cultures. Time taken to resolve symptoms including point tenderness, erythema and hyperthermia, recurrence of breast abscess, and healing time was recorded. Patients were followed until 8 weeks. Culture and sensitivity of the pus were done. Data were analyzed in SPSS 16.0. The mean difference of healing time was significant (P = 0.001). A total of 93.3 per cent were healed in Group B and 76.6 per cent in Group A (P = 0.033). Twenty-two samples (34.37%) had no bacterial yield and the remaining 42 samples (65.6%) yielded 11 anaerobic cultures (17.18%) and 31 aerobic cultures (48.4%). Ultrasound-guided aspiration of breast abscesses with the judicious use of antibiotics is a better treatment modality than incision and drainage.

  16. Human FAN1 promotes strand incision in 5'-flapped DNA complexed with RPA.

    Science.gov (United States)

    Takahashi, Daisuke; Sato, Koichi; Hirayama, Emiko; Takata, Minoru; Kurumizaka, Hitoshi

    2015-09-01

    Fanconi anaemia (FA) is a human infantile recessive disorder. Seventeen FA causal proteins cooperatively function in the DNA interstrand crosslink (ICL) repair pathway. Dual DNA strand incisions around the crosslink are critical steps in ICL repair. FA-associated nuclease 1 (FAN1) is a DNA structure-specific endonuclease that is considered to be involved in DNA incision at the stalled replication fork. Replication protein A (RPA) rapidly assembles on the single-stranded DNA region of the stalled fork. However, the effect of RPA on the FAN1-mediated DNA incision has not been determined. In this study, we purified human FAN1, as a bacterially expressed recombinant protein. FAN1 exhibited robust endonuclease activity with 5'-flapped DNA, which is formed at the stalled replication fork. We found that FAN1 efficiently promoted DNA incision at the proper site of RPA-coated 5'-flapped DNA. Therefore, FAN1 possesses the ability to promote the ICL repair of 5'-flapped DNA covered by RPA. © The Authors 2015. Published by Oxford University Press on behalf of the Japanese Biochemical Society. All rights reserved.

  17. The Evolution of the Appendectomy: From Open to Laparoscopic to Single Incision

    Directory of Open Access Journals (Sweden)

    Noah J. Switzer

    2012-01-01

    Full Text Available Beginning with its initial description by Fitz in the 19th century, acute appendicitis has been a significant long-standing medical challenge; today it remains the most common gastrointestinal emergency in adults. Already in 1894, McBurney advocated for the surgical removal of the inflamed appendix and is credited with the initial description of an Open Appendectomy (OA. With the introduction of minimally invasive surgery, this classic approach evolved into a procedure with multiple, smaller incisions; a technique termed Laparoscopic Appendectomy (LA. There is much literature describing the advantages of this newer approach. To name a few, patients have significantly less wound infections, reduced pain, and a reduction in ileus compared with the OA. In the past few years, Single Incision Laparoscopic Appendectomy (SILA has gained popularity as the next major evolutionary advancement in the removal of the appendix. Described as a pioneer in the era of “scarless surgery,” it involves only one transumbilical incision. Patients are postulated to have reduced post-operative complications such as infection, hernias, and hematomas, as well as a quicker recovery time and less post-operative pain scores, in comparison to its predecessors. In this review, we explore the advancement of the appendectomy from open to laparoscopic to single incision.

  18. Effects of Bank Vegetation and Incision on Erosion Rates in an Urban Stream

    Directory of Open Access Journals (Sweden)

    Emily Arnold

    2018-04-01

    Full Text Available Changing land-use associated with urbanization has resulted in shifts in riparian assemblages, stream hydraulics, and sediment dynamics leading to the degradation of waterways. To combat degradation, restoration and management of riparian zones is becoming increasingly common. However, the relationship between flora, especially the influence of invasive species, on sediment dynamics is poorly understood. Bank erosion and turbidity were monitored in the Tookany Creek and its tributary Mill Run in the greater Philadelphia, PA region. To evaluate the influence of the invasive species Reynoutria japonica (Japanese knotweed on erosion, reaches were chosen based on their riparian vegetation and degree of incision. Bank pins and turbidity loggers were used to estimate sediment erosion. Erosion calculations based on bank pins suggest greater erosion in reaches dominated by knotweed than those dominated by trees. For a 9.5-month monitoring period, there was 29 cm more erosion on banks that were also incised, and 9 cm more erosion in banks with little incision. Turbidity responses to storm events were also higher (77 vs. 54 NTU (nephelometric turbidity unit in reaches with knotweed, although this increase was found when the reach dominated by knotweed was also incised. Thus, this study linked knotweed to increased erosion using multiple methods.

  19. Computed tomography contrast media extravasation: treatment algorithm and immediate treatment by squeezing with multiple slit incisions.

    Science.gov (United States)

    Kim, Sue Min; Cook, Kyung Hoon; Lee, Il Jae; Park, Dong Ha; Park, Myong Chul

    2017-04-01

    In our hospital, an adverse event reporting system was initiated that alerts the plastic surgery department immediately after suspecting contrast media extravasation injury. This system is particularly important for a large volume of extravasation during power injector use. Between March 2011 and May 2015, a retrospective chart review was performed on all patients experiencing contrast media extravasation while being treated at our hospital. Immediate treatment by squeezing with multiple slit incisions was conducted for a portion of these patients. Eighty cases of extravasation were reported from approximately 218 000 computed tomography scans. The expected extravasation volume was larger than 50 ml, or severe pressure was felt on the affected limb in 23 patients. They were treated with multiple slit incisions followed by squeezing. Oedema of the affected limb disappeared after 1-2 hours after treatment, and the skin incisions healed within a week. We propose a set of guidelines for the initial management of contrast media extravasation injuries for a timely intervention. For large-volume extravasation cases, immediate management with multiple slit incisions is safe and effective in reducing the swelling quickly, preventing patient discomfort and decreasing skin and soft tissue problems. © 2016 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  20. Normalized Urinary Flow at Puberty after Tubularized Incised Plate Urethroplasty for Hypospadias in Childhood.

    Science.gov (United States)

    Andersson, Marie; Doroszkiewicz, Monika; Arfwidsson, Charlotte; Abrahamsson, Kate; Sillén, Ulla; Holmdahl, Gundela

    2015-11-01

    An obstructive urinary flow pattern is frequently seen after tubularized incised plate urethroplasty for hypospadias. However, the significance of this finding has not been determined and long-term results are few. We describe postoperative long-term uroflowmetry results after puberty in males who underwent tubularized incised plate urethroplasty in childhood. A total of 126 boys underwent tubularized incised plate urethroplasty for distal penile to mid shaft hypospadias at Queen Silvia Children's Hospital in Gothenburg between 1999 and 2003. Of the patients 48 were toilet trained at surgery. We report on 40 patients who had data available at 2 and 12 months postoperatively, 7 years postoperatively and at puberty (median age 15.0 years, range 13.7 to 17.1). Of the patients 31 had distal and 9 had mid penile hypospadias. Clinical examination, urinary medical history, uroflowmetry and ultrasound measuring residual urine were performed. Maximum urinary flow was correlated to age and voided volume, using Miskolc nomograms for comparison of percentiles. At 1 year postoperatively 15 boys (37.5%) had normal urinary flow (above 25th percentile), compared to 16 (40%) at 7 years and 38 (95%) at puberty (p puberty for boys with hypospadias treated with tubularized incised plate urethroplasty. Unless symptoms occur, a conservative approach seems preferable. Copyright © 2015 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  1. Full-Thickness Retinochoroidal Incision in the Management of Central Retinal Vein Occlusion

    Directory of Open Access Journals (Sweden)

    San-Ni Chen

    2015-01-01

    Full Text Available Purpose. To evaluate the clinical outcomes in patients with central retinal vein occlusion (CRVO treated with full-thickness retinochoroidal incisions and to compare whether there is difference in treatment response in ischemic and nonischemic CRVO. Methods. Retrospective study of patients of CRVO receiving full-thickness retinochoroidal incisions in Changhua Christian Hospital. Fluorescein angiography (FA, slit-lamp biomicroscopy, indirect funduscopy, best corrected visual acuity, and central macular thickness (CMT measured by optical coherence tomography were performed pre- and postoperatively. Patients were divided into an ischemic and nonischemic group according to the findings of FA. Patients were followed up for at least 1 year. Results. Twenty-eight eyes (14 ischemic and 14 nonischemic CRVO were included. Functional retinochoroidal venous anastomosis (RCVA was achieved in 48 of the 65 retinochoroidal incisions (73.8%. Central macular thickness (CMT and retinal hemorrhage decreased significantly after the surgery. Significant visual gain was observed postoperatively in the nonischemic group, but not in the ischemic group. Postoperative complications included vitreous hemorrhage (17.8%, neovascular glaucoma (7.1%, and preretinal fibrovasular membrane (10.7%, all of which were in the ischemic group. Conclusions. RCVA formation induced by retinochoroidal incisions could improve venous flow, and decrease CMT and retinal hemorrhage. However, only eyes with nonischemic CRVO showed visual improvement.

  2. Addition of rectus sheath relaxation incisions to emergency midline laparotomy for peritonitis to prevent fascial dehiscence.

    Science.gov (United States)

    Marwah, Sanjay; Marwah, Nisha; Singh, Mandeep; Kapoor, Ajay; Karwasra, Rajender Kumar

    2005-02-01

    The incidence of fascial dehiscence and incisional hernia after two methods for abdominal wound closure (rectus sheath relaxation incisions and conventional mass closure) was studied in a randomized prospective clinical trial in a consecutive series of 100 patients undergoing midline laparotomy for peritonitis. The two groups were well matched for etiologies of peritonitis, the surgical procedures performed, and the presence of known risk factors for fascial dehiscence. Fifty patients each were randomized either to the conventional continuous mass closure procedure or the rectus sheath relaxation incision technique (designed to increase wound elasticity and decrease tension in the suture line) using identical polypropylene sutures. The incidence of postoperative complications such as duration of ileus, chest infection, and wound infection were not statistically different between the two groups. The intensity of postoperative pain in the rectus sheath relaxation incision group was significantly less. The incidence of wound hematoma was significantly increased in the rectus sheath relaxation incision group. The incidences of fascial dehiscence (16% vs,28%; p cases of peritonitis using the rectus sheath relaxation technique is safe and less painful, provides increased wound elasticity and decreased tension on the suture line, and significantly decreases the incidence of wound dehiscence.

  3. Outcomes of single-stage total arch replacement via clamshell incision

    Directory of Open Access Journals (Sweden)

    Ishizaka Toru

    2011-09-01

    Full Text Available Abstract Background Treatment of complex aortic pathologies involving the transverse arch with extensive involvement of the descending aorta remains a surgical challenge. Since clamshell incision provides superior exposure of the entire thoracic aorta, we evaluated the use of this technique for single-stage total arch replacement by arch vessel reconstruction. Methods The arch-first technique combined with clamshell incision was used in 38 cases of aneurysm and aortic disease in 2008 and 2009. Extensive total arch replacement was used with clamshell incision for reconstruction of arch vessels under deep hypothermic circulatory arrest. Results Overall 30-day mortality was 13%. The mean operating time was approximately 8 hours. Deep hypothermia resulted in mean CPB time exceeding 4.5 hours and mean duration of circulatory arrest was 25 minutes. The overall postoperative temporary and permanent neurologic dysfunction rates were 3% and 3% for elective and 3% and 0% for emergency surgery, respectively. All patients except the five who died in hospital were discharged without nursing care after an average post-operative hospital stay of 35 days. Conclusions The arch-first technique, combined with clamshell incision, provides expeditious replacement of the thoracic aorta with an acceptable duration of hypothermic circulatory arrest and minimizes the risk of retrograde atheroembolism by using antegrade perfusion.

  4. Seismic evidence of glacial-age river incision into the Tahaa barrier reef, French Polynesia

    Science.gov (United States)

    Toomey, Michael; Woodruff, Jonathan D.; Ashton, Andrew D.; Perron, J. Taylor

    2016-01-01

    Rivers have long been recognized for their ability to shape reef-bound volcanic islands. On the time-scale of glacial–interglacial sea-level cycles, fluvial incision of exposed barrier reef lagoons may compete with constructional coral growth to shape the coastal geomorphology of ocean islands. However, overprinting of Pleistocene landscapes by Holocene erosion or sedimentation has largely obscured the role lowstand river incision may have played in developing the deep lagoons typical of modern barrier reefs. Here we use high-resolution seismic imagery and core stratigraphy to examine how erosion and/or deposition by upland drainage networks has shaped coastal morphology on Tahaa, a barrier reef-bound island located along the Society Islands hotspot chain in French Polynesia. At Tahaa, we find that many channels, incised into the lagoon floor during Pleistocene sea-level lowstands, are located near the mouths of upstream terrestrial drainages. Steeper antecedent topography appears to have enhanced lowstand fluvial erosion along Tahaa's southwestern coast and maintained a deep pass. During highstands, upland drainages appear to contribute little sediment to refilling accommodation space in the lagoon. Rather, the flushing of fine carbonate sediment out of incised fluvial channels by storms and currents appears to have limited lagoonal infilling and further reinforced development of deep barrier reef lagoons during periods of highstand submersion.

  5. Influence of different phacoemulsification incision on postoperative corneal astigmatism for cataract patients

    Directory of Open Access Journals (Sweden)

    Zhao-Rong Zeng

    2014-05-01

    Full Text Available AIM: To compare the effect of different phacoemulsification incision on postoperative corneal astigmatism for cataract patients. METHODS: The cataract patients were selected in our hospital. The patients were divided into control group(corneal limbus opposite curved scleral tunnel incision groupand observation group(above the top of cornea or temporal transparent corneal incision grouprandomly. At 1wk; 1 and 3mo after surgery, the change of corneal astigmatism and vision of the patients in two groups were compared and analyzed. RESULTS:Compared with control group, 1wk; 1 and 3mo after surgery, the average corneal astigmatism and surgically induced corneal astigmatism of the patients in observation group were decreased significantly. The visual acuity and corrected visual acuity were increased significantly. There was statistically significant(PPCONCLUSION: Center distance and small incision corneal phacoemulsification can reduce postoperative astigmatism and improve postoperative visual acuity for cataract patients. It provides guarantee for further strengthen the clinical treated effect for cataract patients.

  6. Laparoscopic surgery for esophageal achalasia: Multiport vs single-incision approach.

    Science.gov (United States)

    Fukuda, Shuichi; Nakajima, Kiyokazu; Miyazaki, Yasuhiro; Takahashi, Tsuyoshi; Makino, Tomoki; Kurokawa, Yukinori; Yamasaki, Makoto; Miyata, Hiroshi; Takiguchi, Shuji; Mori, Masaki; Doki, Yuichiro

    2016-02-01

    SILS can potentially improve aesthetic outcomes without adversely affecting treatment outcomes, but these outcomes are uncertain in laparoscopic Heller-Dor surgery. We determined if the degree of patient satisfaction with aesthetic outcomes progressed with the equivalent treatment outcomes after the introduction of a single-incision approach to laparoscopic Heller-Dor surgery. We retrospectively reviewed 20 consecutive esophageal achalasia patients (multiport approach, n = 10; single-incision approach, n = 10) and assessed the treatment outcomes and patient satisfaction with the aesthetic outcomes. In the single-incision approach, thin supportive devices were routinely used to gain exposure to the esophageal hiatus. No statistically significant differences in the operating time (210.2 ± 28.8 vs 223.5 ± 46.3 min; P = 0.4503) or blood loss (14.0 ± 31.7 vs 16.0 ± 17.8 mL; P = 0.8637) were detected between the multiport and single-incision approaches. We experienced no intraoperative complications. Mild dysphagia, which resolved spontaneously, was noted postoperatively in one patient treated with the multiport approach. The reduction rate of the maximum lower esophageal sphincter pressure was 25.1 ± 34.4% for the multiport approach and 21.8 ± 19.2% for the single-incision approach (P = 0.8266). Patient satisfaction with aesthetic outcomes was greater for the single-incision approach than for the multiport approach. When single-incision laparoscopic Heller-Dor surgery was performed adequately and combined with the use of thin supportive devices, patient satisfaction with the aesthetic outcomes was higher and treatment outcomes were equivalent to those of the multiport approach. © 2015 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and John Wiley & Sons Australia, Ltd.

  7. River longitudinal profiles and bedrock incision models: Stream power and the influence of sediment supply

    Science.gov (United States)

    Sklar, Leonard; Dietrich, William E.

    The simplicity and apparent mechanistic basis of the stream power river incision law have led to its wide use in empirical and theoretical studies. Here we identify constraints on its calibration and application, and present a mechanistic theory for the effects of sediment supply on incision rates which spotlights additional limitations on the applicability of the stream power law. On channels steeper than about 20%, incision is probably dominated by episodic debris flows, and on sufficiently gentle slopes, sediment may bury the bedrock and prevent erosion. These two limits bound the application of the stream power law and strongly constrain the possible combination of parameters in the law. In order to avoid infinite slopes at the drainage divide in numerical models of river profiles using the stream power law it is commonly assumed that the first grid cell is unchanneled. We show, however, that the size of the grid may strongly influence the calculated equilibrium relief. Analysis of slope-drainage area relationships for a river network in a Northern California watershed using digital elevation data and review of data previously reported by Hack reveal that non-equilibrium profiles may produce well defined slope-area relationships (as expected in equilibrium channels), but large differences between tributaries may point to disequilibrium conditions. To explore the role of variations in sediment supply and transport capacity in bedrock incision we introduce a mechanistic model for abrasion of bedrock by saltating bedload. The model predicts that incision rates reach a maximum at intermediate levels of sediment supply and transport capacity. Incision rates decline away from the maximum with either decreasing supply (due to a shortage of tools) or increasing supply (due to gradual bed alluviation), and with either decreasing transport capacity (due to less energetic particle movement) or increasing transport capacity (due less frequent particle impacts per unit bed

  8. Channel Incision Driven by Suburbanization: Impacts to Riparian Groundwater Flow and Overbank Flow Frequency

    Science.gov (United States)

    Bowles, C. J.; Lawrence, R. L.; Noll, C.; Hancock, G. S.

    2005-12-01

    Channel incision is a widely observed response to increased flow in urbanized watersheds, but the effects of channel lowering on riparian water tables is not well documented. In a rapidly incising suburban stream in the Virginia Coastal Plain, we hypothesize that stream incision has lowered floodplain water tables and decreased the overbank flow frequency. The monitored stream is a tributary to the James River draining 1.3 km2 of which 15% is impervious cover. Incision has occurred largely through upstream migration of a one meter high knickpoint at a rate of ~1.5 m/yr, primarily during high flow events. We installed 63 wells in six stream-perpendicular transects as well as a cluster of wells around the knickpoint to assess water table elevations beneath the floodplain adjacent to the incising stream. Two transects are located 30 and 50 m upstream of the knickpoint in the unincised floodplain, and the remainder are 5, 30, 70, and 100 m downstream in the incised floodplain. In one transect above and two below, pressure transducers attached to dataloggers provide a high-resolution record of water table changes. Erosion pins were installed and channel cross-sections surveyed to determine streambed stability. Significant differences are observed in bank morphology and groundwater flow above vs. below the knickpoint. Above the knickpoint, the banks are stable, ~3 m wide, and ~0.3 m deep, and widen and deepen slightly toward the knickpoint. The water table is relatively flat and is 0.2-0.4 m below the floodplain surface, and groundwater contours suggest flow is parallel to the stream direction. The water table responds immediately to precipitation events, and rises to the floodplain surface in significant rainfall events. Immediately downstream of the knickpoint, channel width increases by about a meter, and stream depth increases to ~1.5 meters. The water table immediately below the knickpoint possesses a steep gradient, and is up to one meter below the floodplain

  9. Carbon dioxide and future climate

    Energy Technology Data Exchange (ETDEWEB)

    Mitchell, J M

    1977-03-01

    The addition of carbon dioxide to the atmosphere due to burning fossil fuel is discussed. The release rate of carbon dioxide has been growing since at least 1950 at an average rate of 4.3% per year. If all known fossil fuel reserves in the world are consumed, a total of between 5 and 14 times the present amount of carbon dioxide in the atmosphere will be released. The oceans would then be unlikely to withdraw the proportion of perhaps 40% which they are believed to have withdrawn up to the present. The increase in the atmosphere would be in excess of 3 times or conceivably ten times the present amount. If the reserves are used up within a few hundred years, more than half the excess carbon dioxide would remain in the atmosphere after a thousand years. The ''greenhouse'' effect of carbon dioxide is explained. The simulation with numerical models of the effects of carbon dioxide on atmospheric radiation fluxes is discussed. An estimated increase in the average annual temperature of the earth of 2.4 to 2.9C is given for doubling the carbon dioxide content; also a 7% increase in global average precipitation. The effect of increasing carbon dioxide on global mean temperature is viewed in the perspective of the glacial-interglacial cycles. The warming effect of carbon dioxide may induce a ''super-interglacial'' on the present interglacial which is expected to decline toward a new ice age in the next several thousand years. Finally it is proposed that it may be necessary to phase out the use of fossil fuels before all the knowledge is acquired which would necessitate such an action.

  10. Quantification of incisal tooth wear in upper anterior teeth: conventional vs new method using toolmakers microscope and a three-dimensional measuring technique.

    Science.gov (United States)

    Al-Omiri, Mahmoud K; Sghaireen, Mohd G; Alzarea, Bader K; Lynch, Edward

    2013-12-01

    This study aimed to quantify tooth wear in upper anterior teeth using a new CAD-CAM Laser scanning machine, tool maker microscope and conventional tooth wear index. Fifty participants (25 males and 25 females, mean age = 25 ± 4 years) were assessed for incisal tooth wear of upper anterior teeth using Smith and Knight clinical tooth wear index (TWI) on two occasions, the study baseline and 1 year later. Stone dies for each tooth were prepared and scanned using the CAD-CAM Laser Cercon System. Scanned images were printed and examined under a toolmaker microscope to quantify tooth wear and then the dies were directly assessed under the microscope to measure tooth wear. The Wilcoxon Signed Ranks Test was used to analyze the data. TWI scores for incisal edges were 0-3 and were similar at both occasions. Score 4 was not detected. Wear values measured by directly assessing the dies under the toolmaker microscope (range = 113 - 150 μm, mean = 130 ± 20 μm) were significantly more than those measured from Cercon Digital Machine images (range=52-80 μm, mean = 68 ± 23 μm) and both showed significant differences between the two occasions. Wear progression in upper anterior teeth was effectively detected by directly measuring the dies or the images of dies under toolmaker microscope. Measuring the dies of worn dentition directly under tool maker microscope enabled detection of wear progression more accurately than measuring die images obtained with Cercon Digital Machine. Conventional method was the least sensitive for tooth wear quantification and was unable to identify wear progression in most cases. Copyright © 2013 Elsevier Ltd. All rights reserved.

  11. A new technique, combined plication-incision (CPI, for correction of penile curvature

    Directory of Open Access Journals (Sweden)

    Hamed Abdalla Hamed

    Full Text Available ABSTRACT Introduction Penile curvature (PC can be surgically corrected by either corporoplasty or plication techniques. These techniques can be complicated by post-operative: penile shortening, recurrent PC, painful/palpable suture knots and erectile dysfunction. Objective To avoid the complications of corporoplasty and plication techniques using a new technique: combined plication-incision (CPI. Materials and Methods Two groups (1&2 were operated upon: group 1 using CPI and group 2 using the 16-dot technique. In CPI, dots were first marked as in 16 dot technique. In each group of 4 dots the superficial layer of tunica albuginea was transversely incised (3-6mm at the first and last dots. Ethibond 2/0, passed through the interior edge of the first incision plicating the intermediate 2 dots and passed out of the interior edge of the last incision, was tightened and ligated. Vicryle 4/0, passed through the exterior edges of the incisions, was tightened and ligated to cover the ethibond knot. Results Twelve (57.1 % participants in group 2 complained of a bothering palpable knot compared to none in group 1 with statistically significant difference (P=0.005. Postoperative shortening (5mm of erect penis, encountered in 9 participants, was doubled in group 2 but with insignificant difference (P>0.05. Post-operative recurrence of PC, was encountered in only 1 (4.8% participant in group 2, compared to none in group 1, with insignificant difference (P>0.05. Post-operative erectile rigidity was normally maintained in all participants. Conclusion The new technique was superior to the 16-dot technique for correction of PC.

  12. [Is there a relation between mammaplasties incisions and the final shape of the breast?].

    Science.gov (United States)

    Moufarrège, R; Dionyssopoulos, A; Aymeric, A; Sauvageau, J

    2010-04-01

    The results of reduction mammoplasty and mastopexy demonstrate a great variety of shapes derived from the particularities inherent to each technique. More precisely, it has become apparent to us that the usage of an abnormally long vertical scar leads to a suboptimal final shape of the breast due to the excessive projection compared to its height. Although our clientele continually asks to minimize scars, we have noticed a resurgence in the literature of vertical incision mammoplasty techniques albeit with a scar of an excessive length. The multitude of publications leads to an evident and consistent conclusion: breasts reconstructed with an overly long vertical incision all suffer the same deformity characterized by a banana or squash-shaped breast. We studied the totality of publications on vertical incision technique mammoplasty from the last 15 years and realised they all presented the same problem: an abnormally low height/projection ratio. These numbers have been confronted by the golden ratio established by the first author (2005) [1]. The breast's golden ratio developed by Moufarrège is optimal at a number close to, or superior to 2. Results between 2 and 1.5 are acceptable. All height/projection ratios inferior to 1.5 correspond to suboptimal breast shapes. Furthermore, the totality of results in the vertical scar mammoplasty technique which displayed unsatisfying results had a height/projection ratio inferior to 1.5. Those who promote the vertical incision have the greatest drive to encourage other plastic surgeons to abandon the traditional mutilating boat anchor scar. Nevertheless, they should always remember the deforming effect caused by exaggerated vertical incisions which may be avoided by transforming it into an inverted T with short horizontal branches, a small price to pay to obtain a superior aesthetic result. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  13. Laser applications in neurosurgery

    Science.gov (United States)

    Cerullo, Leonard J.

    1985-09-01

    The "false start" of the laser in neurosurgery should not be misconstrued as a denial of the inherent advantages of precision and gentleness in dealing with neural tissue. Rather, early investigators were frustrated by unrealistic expectations, cumbersome equipment, and a general ignorance of microtechnique. By the early 70s, microneurosurgery was well established, surgical laser equipment for free hand and microlinked application had been developed, and a more realistic view of the limitations of the laser had been established. Consequently, the late 70s really heralded the renaissance of the laser in neurosurgery. Since then, there has been an overwhelming acceptance of the tool in a variety of clinical situations, broadly categorized in five groups. 1)|Perhaps the most generally accepted area is in the removal of extra-axial tumors of the brain and spinal cord. These tumors, benign by histology but treacherous by location, do not present until a significant amount of neurological compensation has already occurred. The application of additional trauma to the neural tissue, whether by further tumor growth or surgical manipulation, frequently results in irreversible damage. Here, the ability of the laser to vaporize tissue, in a fairly hemostatic fashion, without mechanical or thermal damage to sensitive surrounding tissues, is essential. 2)|The ability to incise delicate neural tissue with minimal spread of thermal destruction to adjacent functioning tissue makes the laser the ideal instrument when tumors deep under the surface are encountered in the brain or spinal cord. Thus, the second group of applications is in the transgression of normal neural structures to arrive at deeper pathological tissue. 3)|The third area of benefit for the laser in neurosurgery has been in the performance of neuroablative procedures, calling for deliberate destruction of functioning neural tissue in a controlled fashion. Again, the precision and shape confinement of the destructive

  14. Laser Technology.

    Science.gov (United States)

    Gauger, Robert

    1993-01-01

    Describes lasers and indicates that learning about laser technology and creating laser technology activities are among the teacher enhancement processes needed to strengthen technology education. (JOW)

  15. Ultrafast measurements of chlorine dioxide photochemistry

    Energy Technology Data Exchange (ETDEWEB)

    Ludowise, P.D.

    1997-08-01

    Time-resolved mass spectrometry and time-resolved photoelectron spectroscopy are used to study the ultrafast photodissociation dynamics of chlorine dioxide, an important constituent in stratospheric ozone depletion. Chapter 1 introduces these pump/probe techniques, in which a femtosecond pump pulse excites a molecule to a dissociative state. At a later time, a second femtosecond probe pulse ionizes the molecule. The resulting mass and photoelectron spectra are acquired as a function of the delay between the pump and probe pulses, which follows the evolution of the molecule on the excited state. A comparison to other techniques used to study reaction dynamics is discussed. Chapter 2 includes a detailed description of the design and construction of the experimental apparatus, which consists of a femtosecond laser system, a molecular beam time-of-flight spectrometer, and a data acquisition system. The time-of-flight spectrometer is specifically designed to have a short flight distance to maximize the photoelectron collection efficiency without degrading the resolution, which is limited by the bandwidth of the femtosecond laser system. Typical performance of the apparatus is demonstrated in a study of the time-resolved photoelectron spectroscopy of nitric oxide. The results of the time-resolved mass spectrometry experiments of chlorine dioxide are presented in Chapter 3. Upon excitation to the A {sup 2}A{sub 2} state near 3.2 eV, the molecule dissociates through an indirect two-step mechanism. The direct dissociation channel has been predicted to be open, but is not observed. A quantum beat is observed in the OClO{sup +} species, which is described as a vibrational coherence of the optically prepared A {sup 2}A{sub 2} state. Chapter 4 presents the results of the time-resolved photoelectron experiments of chlorine dioxide. At short delay time, the quantum beat of the OClO{sup +} species is observed in the X {sup 1}A{sub 1} state of the ion. At infinite delay, the signal

  16. Cryogen spray cooling during laser tissue welding.

    Science.gov (United States)

    Fried, N M; Walsh, J T

    2000-03-01

    Cryogen cooling during laser tissue welding was explored as a means of reducing lateral thermal damage near the tissue surface and shortening operative time. Two centimetre long full-thickness incisions were made on the epilated backs of guinea pigs, in vivo. India ink was applied to the incision edges then clamps were used to appose the edges. A 4 mm diameter beam of 16 W, continuous-wave, 1.06 microm, Nd:YAG laser radiation was scanned over the incisions, producing approximately 100 ms pulses. There was a delay of 2 s between scans. The total irradiation time was varied from 1-2 min. Cryogen was delivered to the weld site through a solenoid valve in spurt durations of 20, 60 and 100 ms. The time between spurts was either 2 or 4 s, corresponding to one spurt every one or two laser scans. Histology and tensile strength measurements were used to evaluate laser welds. Total irradiation times were reduced from 10 min without surface cooling to under 1 min with surface cooling. The thermal denaturation profile showed less denaturation in the papillary dermis than in the mid-dermis. Welds created using optimized irradiation and cooling parameters had significantly higher tensile strengths (1.7 +/- 0.4 kg cm(-2)) than measured in the control studies without cryogen cooling (1.0 +/- 0.2 kg cm(-2)) (p laser welding results in increased weld strengths while reducing thermal damage and operative times. Long-term studies will be necessary to determine weld strengths and the amount of scarring during wound healing.

  17. Extraction of Uranium Using Nitrogen Dioxide and Carbon Dioxide for Spent Fuel Reprocessing

    Energy Technology Data Exchange (ETDEWEB)

    Kayo Sawada; Daisuke Hirabayashi; Youichi Enokida [EcoTopia Science Institute, Nagoya University, Nagoya, 464-8603 (Japan)

    2008-07-01

    For the reprocessing of spent nuclear fuels, a new method to extract actinides from spent fuel using highly compressed gases, nitrogen dioxide and carbon dioxide was proposed. Uranium extraction from broken pieces, whose average grain size was 5 mm, of uranium dioxide pellet with nitrogen dioxide and carbon dioxide was demonstrated in the present study. (authors)

  18. Endoscopic laser-urethroplasty

    Science.gov (United States)

    Gilbert, Peter

    2006-02-01

    The objective was to prove the advantage of endoscopic laser-urethroplasty over internal urethrotomy in acquired urethral strictures. Patients and Method: From January, 1996 to June, 2005, 35 patients with a mean age of 66 years were submitted to endoscopic laser-urethroplasty for strictures of either the bulbar (30) or membranous (5) urethra. The operations were carried out under general anesthesia. First of all, the strictures were incised at the 4, 8 and 12 o'clock position by means of a Sachse-urethrotom. Then the scar flap between the 4 and 8 o'clock position was vaporized using a Nd:YAG laser, wavelength 1060 nm and a 600 pm bare fiber, the latter always being in contact with the tissue. The laser worked at 40W power in continuous mode. The total energy averaged 2574 J. An indwelling catheter was kept in place overnight and the patients were discharged the following day. Urinalysis, uroflowmetry and clinical examination were performed at two months after surgery and from then on every six months. Results: No serious complications were encountered. Considering a mean follow-up of 18 months, the average peak flow improved from 7.3 ml/s preoperatively to 18.7 mVs postoperatively. The treatment faded in 5 patients ( 14.3% ) who finally underwent open urethroplasty. Conclusions: Endoscopic laser-urethroplasty yields better short-term results than internal visual urethrotomy. Long-term follow-up has yet to confirm its superiority in the treatment of acquired urethral strictures.

  19. Reducing carbon dioxide to products

    Science.gov (United States)

    Cole, Emily Barton; Sivasankar, Narayanappa; Parajuli, Rishi; Keets, Kate A

    2014-09-30

    A method reducing carbon dioxide to one or more products may include steps (A) to (C). Step (A) may bubble said carbon dioxide into a solution of an electrolyte and a catalyst in a divided electrochemical cell. The divided electrochemical cell may include an anode in a first cell compartment and a cathode in a second cell compartment. The cathode may reduce said carbon dioxide into said products. Step (B) may adjust one or more of (a) a cathode material, (b) a surface morphology of said cathode, (c) said electrolyte, (d) a manner in which said carbon dioxide is bubbled, (e), a pH level of said solution, and (f) an electrical potential of said divided electrochemical cell, to vary at least one of (i) which of said products is produced and (ii) a faradaic yield of said products. Step (C) may separate said products from said solution.

  20. Minimal Nasolabial Incision Technique for Nasolabial Fold Modification in Patients With Facial Paralysis.

    Science.gov (United States)

    Faris, Callum; Heiser, Alyssa; Jowett, Nate; Hadlock, Tessa

    2018-03-01

    Creation of symmetrical nasolabial folds (NLFs) is important in the management of the paralyzed face. Established techniques use a linear incision in the NLF, and technical refinements now allow the linear incision to be omitted. This retrospective case series was conducted in a tertiary care setting from February 2, 2017, to June 7, 2017. Participants were all patients (N = 21) with peripheral facial paralysis who underwent NLF modification that used the minimal nasolabial incision technique at the Massachusetts Eye and Ear Infirmary Facial Nerve Center from February 1, 2015, through August 31, 2016. Patient-reported outcome measures using the validated, quality-of-life Facial Clinimetric Evaluation (FaCE) Scale; clinician-reported facial function outcomes using a validated electronic clinician-graded facial paralysis assessment (eFACE); layperson assessment of the overall aesthetic outcome of the NLF; and expert-clinician scar assessment of the NLF. Of the 21 patients who underwent NLF modification that used the minimal nasolabial incision technique, 9 patients (43%) were female and 12 (57%) were male. The mean age was 41 (range, 9-90) years; 17 patients (81%) were adults (≥18 years) and 4 (19%) were children (<18 years). Overall, significant improvements were observed after NLF modification in all outcome measures as graded by both clinicians and patients. The mean (SD) scores for total eFACE were 60.7 (14.9) before the operation and 77.2 (8.9) after the operation (mean difference, 16.5 [95% CI, 8.5-24.2]; P < .001). The mean (SD) static eFACE scores were 61.4 (20.6) before the operation and 82.7 (12.4) after the operation (mean difference, 21.3 [95% CI, 10.7-31.9]; P < .001). The mean (SD) FaCE quality-of-life scores were 51.3 (20.1) before the operation and 70.3 (12.6) after the operation (mean difference, 19.0 [95% CI, 6.5-31.6]; P  =  .001). The layperson self-assessment of the overall aesthetic outcome of the NLF modification was

  1. Method for carbon dioxide sequestration

    Science.gov (United States)

    Wang, Yifeng; Bryan, Charles R.; Dewers, Thomas; Heath, Jason E.

    2017-12-05

    A method for geo-sequestration of a carbon dioxide includes selection of a target water-laden geological formation with low-permeability interbeds, providing an injection well into the formation and injecting supercritical carbon dioxide (SC-CO.sub.2) and water or bine into the injection well under conditions of temperature, pressure and density selected to cause the fluid to enter the formation and splinter and/or form immobilized ganglia within the formation.

  2. Recuperative supercritical carbon dioxide cycle

    Science.gov (United States)

    Sonwane, Chandrashekhar; Sprouse, Kenneth M; Subbaraman, Ganesan; O'Connor, George M; Johnson, Gregory A

    2014-11-18

    A power plant includes a closed loop, supercritical carbon dioxide system (CLS-CO.sub.2 system). The CLS-CO.sub.2 system includes a turbine-generator and a high temperature recuperator (HTR) that is arranged to receive expanded carbon dioxide from the turbine-generator. The HTR includes a plurality of heat exchangers that define respective heat exchange areas. At least two of the heat exchangers have different heat exchange areas.

  3. Solubility of plutonium dioxide aerosols, in vitro

    International Nuclear Information System (INIS)

    Newton, G.J.; Kanapilly, G.M.

    1976-01-01

    Solubility of plutonium aerosols is an important parameter in establishing risk estimates for industrial workers who might accidentally inhale these materials and in evaluating environmental health impacts associated with Pu. In vitro solubility of industrial plutonium aerosols in a simulated lung fluid is compared to similar studies with ultrafine aerosols from laser ignition of delta phase plutonium metal and laboratory-produced spherical particles of 238 PuO 2 and 239 PuO 2 . Although relatively insoluble, industrial plutonium-mixed oxide aerosols were much more soluble than laboratory-produced plutonium dioxide particles. Chain agglomerate aerosols from laser ignition of metallic Pu indicated in vitro dissolution half-times of 10 and 50 days for activity median aerodynamic diameter (AMAD) of 0.7 and 2.3 μm, respectively. Plutonium-containing mixed oxide aerosols indicated dissolution half-times of 40 to 500 days for particles formed by industrial powder comminution and blending. Centerless grinding of fuel pellets yielded plutonium-containing aerosols with dissolution half-times of 1200 to 8000 days. All mixed oxide particles were in the size range 1.0 μm to 2.5 μm AMAD

  4. The influence of water/air cooling on collateral tissue damage using a diode laser with an innovative pulse design (micropulsed mode)-an in vitro study.

    Science.gov (United States)

    Beer, F; Körpert, W; Buchmair, A G; Passow, H; Meinl, A; Heimel, P; Moritz, A

    2013-05-01

    Since the diode laser is a good compromise for the daily use in dental offices, finding usage in numerous dental indications (e.g., surgery, periodontics, and endodontics), the minimization of the collateral damage in laser surgery is important to improve the therapeutical outcome. The aim of this study was to investigate the effect of water/air cooling on the collateral thermal soft tissue damage of 980-nm diode laser incisions. A total of 36 mechanically executed laser cuts in pork liver were made with a 980-nm diode laser in micropulsed mode with three different settings of water/air cooling and examined by histological assessment to determine the area and size of carbonization, necrosis, and reversible tissue damage as well as incision depth and width. In our study, clearly the incision depth increased significantly under water/air cooling (270.9 versus 502.3 μm-test group 3) without significant changes of incision width. In test group 2, the total area of damage was significantly smaller than in the control group (in this group, the incision depth increases by 65 %). In test group 3, the total area of damage was significantly higher (incision depth increased by 85 %), but the bigger part of it represented a reversible tissue alteration leaving the amount of irreversible damage almost the same as in the control group. This first pilot study clearly shows that water/air cooling in vitro has an effect on collateral tissue damage. Further studies will have to verify, if the reduced collateral damage we have proved in this study can lead to accelerated wound healing. Reduction of collateral thermal damage after diode laser incisions is clinically relevant for promoted wound healing.

  5. Lasers in Dentistry: Is It Really Safe?

    Directory of Open Access Journals (Sweden)

    Hamed Mortazavi

    2016-01-01

    Full Text Available Introduction: Lasers are used in various disciplines in dentistry such as restorative dentistry, endodontics, periodontics, pedodontics, and oral and maxillofacial surgery. Despite many advantages of dental lasers, this method might have some adverse effects. The aim of this review article is to debate about the impacts of lasers on orodental tissues. Methods: An electronic search was accomplished using specialized databases such as Google Scholar, PubMed, PubMed Central, Science Direct, and Scopus to find relevant studies by using keywords such as “laser”, “dentistry”, “adverse effect”, and “side effect”. Results: Several adverse effects of laser were identified such as impacts on dental pulp, effects on tooth surface, subcutaneous and submucosal effects, histopathological changes, and infection transmission due to laser smoke. During dental procedures, necrosis of the pulp, periodontal ligament and odontoblasts, cemental lysis, bone resorption, hypo/hyperpigmentation, burns, itching, and scarring might occur. In addition, laser can weaken the dentin by inducing surface cracks. Restorative procedures by laser might increase microleakage and decrease shear bond strength, as well as microhardness of tooth walls. Meanwhile, laser surgery might cause emphysema after abscess incision and drainage, frenectomy, flap elevation, and gingivoplasty. Conclusion: Practitioners should be very cautious in treatment planning and case selection during laser-based therapeutic procedures.

  6. Picosecond laser ablation of porcine sclera

    Science.gov (United States)

    Góra, Wojciech S.; Harvey, Eleanor M.; Dhillon, Baljean; Parson, Simon H.; Maier, Robert R. J.; Hand, Duncan P.; Shephard, Jonathan D.

    2013-03-01

    Lasers have been shown to be successful in certain medical procedures and they have been identified as potentially making a major contribution to the development of minimally invasive procedures. However, the uptake is not as widespread and there is scope for many other applications where laser devices may offer a significant advantage in comparison to the traditional surgical tools. The purpose of this research is to assess the potential of using a picosecond laser for minimally invasive laser sclerostomy. Experiments were carried out on porcine scleral samples due to the comparable properties to human tissue. Samples were prepared with a 5mm diameter trephine and were stored in lactated Ringer's solution. After laser machining, the samples were fixed in 3% glutaraldehyde, then dried and investigated under SEM. The laser used in the experiments is an industrial picosecond TRUMPF TruMicro laser operating at a wavelength of 1030nm, pulse length of 6ps, repetition rate of 1 kHz and a focused spot diameter of 30μm. The laser beam was scanned across the samples with the use of a galvanometer scan head and various ablation patterns were investigated. Processing parameters (pulse energy, spot and line separation) which allow for the most efficient laser ablation of scleral tissue without introducing any collateral damage were investigated. The potential to create various shapes, such as linear incisions, square cavities and circular cavities was demonstrated.

  7. Cannabidiol Is a Potential Therapeutic for the Affective-Motivational Dimension of Incision Pain in Rats

    Directory of Open Access Journals (Sweden)

    Karina Genaro

    2017-06-01

    Full Text Available Background: Pain involves different brain regions and is critically determined by emotional processing. Among other areas, the rostral anterior cingulate cortex (rACC is implicated in the processing of affective pain. Drugs that interfere with the endocannabinoid system are alternatives for the management of clinical pain. Cannabidiol (CBD, a phytocannabinoid found in Cannabis sativa, has been utilized in preclinical and clinical studies for the treatment of pain. Herein, we evaluate the effects of CBD, injected either systemically or locally into the rACC, on mechanical allodynia in a postoperative pain model and on the negative reinforcement produced by relief of spontaneous incision pain. Additionally, we explored whether CBD underlies the reward of pain relief after systemic or rACC injection.Methods and Results: Male Wistar rats were submitted to a model of incision pain. All rats had mechanical allodynia, which was less intense after intraperitoneal CBD (3 and 10 mg/kg. Conditioned place preference (CPP paradigm was used to assess negative reinforcement. Intraperitoneal CBD (1 and 3 mg/kg inverted the CPP produced by peripheral nerve block even at doses that do not change mechanical allodynia. CBD (10 to 40 nmol/0.25 μL injected into the rACC reduced mechanical allodynia in a dose-dependent manner. CBD (5 nmol/0.25 μL did not change mechanical allodynia, but reduced peripheral nerve block-induced CPP, and the higher doses inverted the CPP. Additionally, CBD injected systemically or into the rACC at doses that did not change the incision pain evoked by mechanical stimulation significantly produced CPP by itself. Therefore, a non-rewarding dose of CBD in sham-incised rats becomes rewarding in incised rats, presumably because of pain relief or reduction of pain aversiveness.Conclusion: The study provides evidence that CBD influences different dimensions of the response of rats to a surgical incision, and the results establish the rACC as a

  8. The "Propeller" incision for transpalatal advancement pharyngoplasty: a new approach to reduce post-operative oronasal fistulae.

    Science.gov (United States)

    Shine, Neville Patrick; Lewis, Richard Hamilton

    2008-09-01

    To present a new soft tissue approach for transpalatal advancement pharyngoplasty (TPA), the propeller incision, and to compare the rates of post-operative oronasal fistula in those undergoing TPA with the traditional "Gothic Arch" incision described by Woodson and those with the propeller incision. A prospectively maintained adult sleep apnoea surgery database was used to identify those patients undergoing TPA, either alone or in combination with other procedures, for obstructive sleep apnoea syndrome (OSAS) between February 2001 and September 2006 in a tertiary referral centre by a single surgeon (RHL). In addition to the incision used during TPA, patient demographic data, previous surgery of the upper airways, smoking history, pre-operative body mass index, respiratory disturbance index, oxygen saturation index and the occurrence of oronasal fistula post-operatively, were recorded. The propeller incision technique is described. A total of 89 patients who underwent TPA were identified. A total of 49 patients had a "Gothic Arch" incision and 40 had a "Propeller" incision. The two groups of patients were comparable in age, sex, previous tonsillar and uvulopalatopharyngoplasty surgery, smoking histories and pre-operative disease severity. In the "Gothic Arch" group, eight patients (16%) developed oronasal fistulae in the post-operative period versus only one patient (2.5%) in the "Propeller" group. The difference between the two groups was statistically significant (P=0.038, Fisher's exact test). Of the total cases with post-operative oronasal fistula (n=9), only one patient (from the Gothic Arch incision group) required operative closure which was performed under local anesthesia and healed without complication. The propeller incision provides an anatomically sensible axial-based flap that provides adequate access to perform TPA. It is associated with a lower incidence of oronasal fistula and is recommended by the authors.

  9. Hydrodynamic effects in laser cutting of biological tissue phantoms

    Science.gov (United States)

    Zhigarkov, V. S.; Yusupov, V. I.; Tsypina, S. I.; Bagratashvili, V. N.

    2017-11-01

    We study the thermal and transport processes that occur in the course of incision formation at the surface of a biological tissue phantom under the action of near-IR, moderate-power, continuous-wave laser radiation (λ = 1.94 μm) delivered by means of an optical fibre with an absorbing coating on its exit face. It is shown that in addition to the thermal effect, the laser-induced hydrodynamic effects caused by the explosive boiling of the interstitial water make a large contribution to the phantom destruction mechanism. These effects lead to the tissue rupture accompanied by the ejection of part of the fragmented substance from the site of laser impact and the formation of highly porous structure near the incision surface. We have found that the depth, the width and the relief of the laser incision wall in the case of using the optical fibre moving with a constant velocity, depend on the fibre tilt angle with respect to the phantom surface, as well as the direction of the fibre motion.

  10. Uranium dioxide and beryllium oxide enhanced thermal conductivity nuclear fuel development

    International Nuclear Information System (INIS)

    Andrade, Antonio Santos; Ferreira, Ricardo Alberto Neto

    2007-01-01

    The uranium dioxide is the most used substance as nuclear reactor fuel for presenting many advantages such as: high stability even when it is in contact with water in high temperatures, high fusion point, and high capacity to retain fission products. The conventional fuel is made with ceramic sintered pellets of uranium dioxide stacked inside fuel rods, and presents disadvantages because its low thermal conductivity causes large and dangerous temperature gradients. Besides, the thermal conductivity decreases further as the fuel burns, what limits a pellet operational lifetime. This research developed a new kind of fuel pellets fabricated with uranium dioxide kernels and beryllium oxide filling the empty spaces between them. This fuel has a great advantage because of its higher thermal conductivity in relation to the conventional fuel. Pellets of this kind were produced, and had their thermophysical properties measured by the flash laser method, to compare with the thermal conductivity of the conventional uranium dioxide nuclear fuel. (author) (author)

  11. Single-incision video-assisted anatomical segmentectomy with handsewn bronchial closure for endobronchial lipoma.

    Science.gov (United States)

    Galvez, Carlos; Sesma, Julio; Bolufer, Sergio; Lirio, Francisco; Navarro-Martinez, Jose; Galiana, Maria; Baschwitz, Benno; Rivera, Maria Jesus

    2016-08-01

    Endobronchial lipomas are rare benign tumors whose symptoms are usually confused with recurrent infections or even asthma diagnosis, and mostly caused by endobronquial obstructive component which also conditions severity. We report a case of a 60-year-old man with a right-lower lobe upper-segment endobronchial myxoid tumor with uncertain diagnosis. We performed a single incision video-assisted anatomical segmentectomy and wedge bronchoplasty with handsewn closure to achieve complete resection and definitive diagnosis. During the postoperative air leak was not observed and there was no complication, with low pain scores and complete recovery. Final pathological exam showed endobronchial lipoma. Single-incision (SI) anatomical segmentectomies are lung-sparing resections for benign or low-grade malignancies with diagnostic and therapeutic value, and the need for a wedge bronchoplasty is not a necessary indication for conversion to multiport or open thoracotomy.

  12. European Hernia Society guidelines on the closure of abdominal wall incisions

    DEFF Research Database (Denmark)

    Muysoms, F E; Antoniou, S A; Bury, K

    2015-01-01

    using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach and methodological guidance was taken from Scottish Intercollegiate Guidelines Network (SIGN). The literature search included publications up to April 2014. The guidelines were written using the AGREE II...... of rapidly absorbable sutures. It is suggested using a slowly absorbable monofilament suture in a single layer aponeurotic closure technique without separate closure of the peritoneum. A small bites technique with a suture to wound length (SL/WL) ratio at least 4/1 is the current recommended method......, it is suggested using the smallest trocar size adequate for the procedure and closure of the fascial defect if trocars larger or equal to 10 mm are used. For single incision laparoscopic surgery, we suggest meticulous closure of the fascial incision to avoid an increased risk of incisional hernias....

  13. Can post-sternotomy mediastinitis be prevented by a closed incision management system?

    Directory of Open Access Journals (Sweden)

    Dohmen, Pascal M.

    2014-09-01

    Full Text Available [english] Post-sternotomy mediastinitis is a serious complication after cardiothoracic surgery and contribute significantly to post-operative morbidity, mortality, and healthcare costs. Negative pressure wound therapy is today’s golden standard for post-sternotomy mediastinitis treatment. A systematic literature search was conducted at PubMed until October 2012 to analyse whether vacuum-assisted closure technique prevents mediastinitis after clean surgical incisions closure. Today’s studies showed reduction of post-sternotomy mediastinitis including a beneficial socio-economic impact. Current studies, however included only high-risk patients, hence furthermore, larger randomised controlled trials are warranted to clarify the benefit for using surgical incision vacuum management systems in the general patient population undergoing sternotomy and clarify risk factor interaction.

  14. Radiological assessment of 50 cases of incisive or maxillary neoplasia in the dog

    International Nuclear Information System (INIS)

    Frew, D.G.; Dobson, J.M.

    1992-01-01

    This paper reviews the radiological features of 50 canine incisive or maxillary tumours and discusses the value of radiological assessment in the diagnosis and staging of these tumours. The 50 tumours examined included 21 sarcomas, 15 carcinomas, three melanomas and an assortment of benign tumours of the oral cavity. There was not any site specificity for the different histological tumour types within the upper dental arcade, although fibrosarcomas had a tendency to be maxillary whereas the squamous cell carcinomas were equally distributed between the incisive and maxillary regions. Seventy-eight per cent of fibrosarcomas, 82 per cent of squamous cell carcinoma and all three melanomas examined showed radiological evidence of bone involvement. Radiographic changes were also seen in the benign tumours. The pattern of growth of tumours correlated with the radiological changes observed. Malignant tumours showed a tendency to irregular or aggressive bone loss whereas bone production predominated in the benign tumours

  15. Diagnosis and management of maxillary incisors affected by incisal wear: an interdisciplinary case report.

    Science.gov (United States)

    Bernardo, Jussara Karina; Maia, Elaine A Vilela; Cardoso, Antônio Carlos; de Araújo Júnior, Edson Medeiros; Monteiro Júnior, Sylvio

    2002-01-01

    In the attempt to restore anterior teeth affected by erosion and bruxism, many clinicians have been frustrated with the constant restorative failures. Frequently, these failures are attributed to the restorative materials employed, especially in cases in which composite resins are used. However, some flaws of the restorations are related to the oversight of occlusal principles. The purpose of this article is to discuss the etiology, signs, and symptoms of incisal wear, with special attention to that caused by bruxism and chemical erosion. Relatively simple management techniques (e.g., occlusal adjustment, adhesive restorations) are proposed, and the diagnosis and management of a representative clinical case is presented. In some cases of bruxism and/or dental erosion, it is possible to acquire space to recuperate the esthetics and function of maxillary incisors affected by incisal wear through a conservative treatment associated with the control of the etiologic factors.

  16. A STUDY ON EFFICACY OF MANUAL SMALL INCISION CATARACT SURGERY BY TEMPORAL APPROACH

    Directory of Open Access Journals (Sweden)

    Vinodhini Kannan

    2018-01-01

    Full Text Available BACKGROUND Manual Small Incision Cataract Surgery (MSICS is a well-known technique of cataract surgery owing to its advantage of a selfsealing suture less incision with least surgically induced astigmatism at a low cost. It is a safe, simple, consistent, stable and cost-effective technique with various modifications that involve site, size, type of incision and method of nucleus delivery. One such modification is Temporal Incision MSICS, where the cataract surgery is done by a temporal approach, which is equally good compared to the superior incision. This study was done retrospectively to analyse the visual outcome of patients operated by Manual SICS - Temporal Approach, using the WHO criteria and to establish its efficacy as a good surgical technique. MATERIALS AND METHODS Records of patients operated for senile cataract by a single surgeon by Temporal MSICS using a temporal sclerocorneal incision of 6-6.5 mm, during a 1-year period, were analysed retrospectively. Post-operative followup records of POD-1 and subsequent follow-ups at 1 st week and 6 th week were recorded for visual outcome. RESULTS Out of the 83 cases analysed retrospectively, majority of them were found to be between 61-70 years with a female Preponderance. Most of the cases were found to have senile immature cataract (55 patients, with Grade III nuclear sclerosis (52 cases. The pre-operative visual acuity was poor <6/60 in 72 cases (86.7% and borderline in 11 cases (14.5%. 55 cases (66.3% had a 6.5 mm scleral incision and the remaining 28 cases (33.7% had a 6 mm incision. Average duration of surgery noted was 8.35 minutes. Striate Keratopathy was the most common 1 st POD complication followed by corneal oedema. Striate keratopathy was the most common complication at the 1 st week followup followed by pigment dispersion. Majority of cases (76 cases were found to have been complication free at the end of 6 weeks. At the end of 6 weeks post-operatively as per records, 80 cases

  17. Single-incision, laparoscopic-assisted jejunal resection and anastomosis following a gunshot wound.

    Science.gov (United States)

    Rubin, Jacob A; Shigemoto, Reynsen; Reese, David J; Case, J Brad

    2015-01-01

    A 2 yr old castrated male Pomeranian was evaluated for a 6 wk history of chronic vomiting, intermittent anorexia, and lethargy. Physical examination revealed a palpable, nonpainful, soft-tissue mass in the midabdominal area. Abdominal radiographs and ultrasound revealed a focal, eccentric thickening of the jejunal wall with associated jejunal mural foreign body and partial mechanical obstruction. Following diagnosis of a partial intestinal obstruction as the cause of chronic vomiting, the patient underwent general anesthesia for a laparoscopic-assisted, midjejunal resection and anastomosis using a single-incision laparoscopic surgery port. The patient was discharged the day after surgery, and clinical signs abated according to information obtained during a telephone interview conducted 2 and 8 wk postoperatively. The dog described in this report is a unique case of partial intestinal obstruction treated by laparoscopic-assisted resection and anastomosis using a single-incision laparoscopic surgery port.

  18. Early response of local steroid injection versus mini incision technique in treatment of carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Awan, A.S.; Khan, A.; Afridi, S.A.; Khan, R.S.

    2015-01-01

    Carpal tunnel syndrome Carpal tunnel syndrome (CTS) is one of the commonest peripheral neuropathies which effects mainly middle aged women. Different techniques are being tried to decrease the post-operative pain in patients operated for CTS. The objective of this study was to compare effectiveness of local injection of steroid and mini incision technique in the treatment of carpal tunnel syndrome. Methods: This randomized control trial was conducted at department of Orthopedics and department of Neurosurgery, Ayub Teaching Hospital, Abbottabad from Aug 2011 to Feb 2013. A total of 116 patients of CTS were randomly allocated to either of the two groups. Fifty-eight Patient in Group A were subjected to local steroid injection and the same number of patient in Group B underwent mini incision technique. All patients of were advised to report to the OPD after one month to determine intervention effectiveness in terms of improvement in at least one grade of pain. Results: In this study mean age of the patients was 32.8 ± 5.1 years. Female gender was in dominance with 99 (86.3%) cases. In this study we compared the effectiveness of local steroid injection and mini incision technique in the treatment of carpel tunnel syndrome. We found out that the steroid injection was effective in 69.0% cases while mini incision technique was effective in 56.9% cases. The difference being statistically insignificant with a p-value of 0.17. Conclusion: The difference in pain after 1 month of the intervention was not statistically significant. (author)

  19. Preputial reconstruction and tubularized incised plate urethroplasty in proximal hypospadias with ventral penile curvature

    OpenAIRE

    Bhat, Amilal; Gandhi, Ajay; Saxena, Gajendra; Choudhary, Gautam Ram

    2010-01-01

    Aims : Objective of this study was to assess the feasibility and results of preputial reconstruction and tubularized incised plate urethroplasty (TIP) in patients of proximal hypospadias with ventral penile curvature. Materials and Methods : Twenty-seven patients of proximal hypospadias who underwent preputioplasty with TIP were evaluated retrospectively. Ventral curvature was corrected by mobilization of the urethral plate with the corpus spongiosum and the proximal urethra; dorsal plica...

  20. Infilling and flooding of the Mekong River incised valley during deglacial sea-level rise

    Science.gov (United States)

    Tjallingii, Rik; Stattegger, Karl; Wetzel, Andreas; Van Phach, Phung

    2010-06-01

    The abrupt transition from fluvial to marine deposition of incised-valley-fill sediments retrieved from the southeast Vietnamese shelf, accurately records the postglacial transgression after 14 ka before present (BP). Valley-filling sediments consist of fluvial mud, whereas sedimentation after the transgression is characterized by shallow-marine carbonate sands. This change in sediment composition is accurately marked in high-resolution X-ray fluorescence (XRF) core scanning records. Rapid aggradation of fluvial sediments at the river mouth nearly completely filled the Mekong incised valley prior to flooding. However, accumulation rates strongly reduced in the valley after the river-mouth system flooded and stepped back. This also affected the sediment supply to deeper parts of the southeast Vietnamese shelf. Comparison of the Mekong valley-filling with the East Asian sea-level history of sub- and inter-tidal sediment records shows that the transgressive surface preserved in the incised-valley-fill records is a robust sea-level indicator. The valley was nearly completely filled with fluvial sediments between 13.0 and 9.5 ka BP when sea-level rose rather constantly with approximately 10 mm/yr, as indicated by the East Asian sea-level record. At shallower parts of the shelf, significant sediment reworking and the establishment of estuarine conditions at the final stage of infilling complicates accurate dating of the transgressive surface. Nevertheless, incised-valley-fill records and land-based drill sites indicate a vast and rapid flooding of the shelf from the location of the modern Vietnamese coastline to the Cambodian lowlands between 9.5 ka and 8.5 ka BP. Fast flooding of this part of the shelf is related with the low shelf gradient and a strong acceleration of the East Asian sea-level rise from 34 to 9 meter below modern sea level (mbsl) corresponding to the sea-level jump of melt water pulse (MWP) 1C.

  1. Modified Lengthening Temporalis Myoplasty Involving an Extended Lazy-S Incision to Avoid Facial Scar Formation.

    Science.gov (United States)

    Oji, Tomito; Hayashi, Akiteru; Ogino, Akihiro; Onishi, Kiyoshi

    2018-05-01

    Lengthening temporalis myoplasty is a faster and less invasive alternative to free muscle transfer for smile reconstruction. However, it requires a nasolabial fold incision, which leaves a midfacial scar. Based on esthetic considerations, a modified approach, involving an extended lazy-S (parotidectomy) incision instead of a nasolabial fold incision, was developed. A cadaveric study involving 10 hemifaces was conducted. From February 2013 to March 2016, the modified lengthening temporalis myoplasty procedure was employed in 10 patients. The results were graded from 1 (poor) to 5 (excellent) according to the Terzis grading system. The excursion of the oral commissure was also measured. The extended lazy-S incision provides easy and safe access to the coronoid process and good visibility. The patients' mean age was 56.5 years, and the mean duration of the postoperative follow-up period was 22.2 months. The patients' underlying conditions included acoustic neuroma (n = 2), Bell palsy (n = 3), congenital conditions (n = 2), brain infarction (n = 1), Ramsay Hunt syndrome (n = 1), and malignant parotid lymphoma (n = 1). One patient suffered a surgical site infection, which was successfully treated with irrigation. All the patients achieved improvements in smile symmetry: 2, 5, and 3 patients obtained excellent, good, and moderate results, respectively. The excursion of the oral commissure ranged from 5 to 10 mm. The modified lengthening temporalis myoplasty procedure provides satisfactory functional outcomes without causing significant complications. It does not leave a facial scar and is a preferable option, especially for young and female patients, and patients who have undergone ablative surgery involving the parotid region.

  2. Lateral Nail Fold Incision Technique for Venous Anastomosis in Fingertip Replantation.

    Science.gov (United States)

    Jeon, Byung-Joon; Yang, Jae-Won; Roh, Si Young; Ki, Sae Hwi; Lee, Dong Chul; Kim, Jin Soo

    2016-01-01

    Successful venous anastomosis is one of the most important factors in fingertip replantation. Volar veins in the fingertip course proximally in a random pattern, which makes it difficult to find out the exact locations. Although dorsal veins in the lateral nail fold have constant location and adequate diameter for anastomosis, they have been known as hard to dissect from the immobile subcutaneous tissue. The authors present a new lateral nail fold incision technique for venous anastomosis in the fingertip amputations. From February 2010 to October 2010, 9 replantations using the new incision and venous anastomosis technique were performed in 9 patients. The levels of amputations were from the nail base to half of the nail bed. After repairing the proper digital arteries, a skin incision was made along the junction between the lateral nail fold and nail bed. Careful dissection was performed to isolate the veins in the lateral nail fold. After evaluation of the suitability of the vessel, venous anastomosis was performed. Seven male and 2 female patients were enrolled in this study. Appropriate dorsal veins for anastomosis could be found in 8 of 9 patients. All the replanted stumps survived without venous congestion and following additional procedures. A sizable volar or dorsal vein could not be found in 1 patient. The salvage technique was required in this patient. Dorsal veins in the lateral nail fold can be found easily because of the constant anatomical location. The new incision on the lateral nail fold provides not only sufficient operative field for anastomosis but also additional opportunity of successful venous anastomosis in the selected cases. The authors, therefore, propose this technique as an effective method for an alternative venous anastomosis in the zone I replantation.

  3. Virtual Incision Pattern Planning using Three-Dimensional Images for Optimization of Syndactyly Surgery

    Directory of Open Access Journals (Sweden)

    Inge A. Hoevenaren, MD

    2018-03-01

    Full Text Available Summary:. Syndactyly is a congenital condition characterized by fusion of the fingers. If not treated correctly during infancy, syndactyly may hinder the normal development of hand function. Many surgical techniques have been developed, with the main goal to create a functional hand with the smallest number of operative corrections. Therefore, exact preoperative planning of the reconstructive procedure is essential. An imaging method commonly used for preoperative planning is 3-dimensional (3D surface imaging. The goal of this study was to implement the use of this technique in hand surgery, by designing a virtual planning tool for a desyndactylization procedure based on 3D hand images. A 3D image of a silicon syndactyly model was made on which the incision pattern was virtually designed. A surgical template of this pattern was printed, placed onto the silicon model and delineated. The accuracy of the transfer from the virtual delineation toward the real delineation was calculated, resulting in a mean difference of 0.82 mm. This first step indicates that by using 3D images, a virtual incision pattern can be created and transferred back onto the patient successfully in an easy and accurate way by using a template. Thereafter, 3D hand images of 3 syndactyly patients were made, and individual virtual incision patterns were created. Each pattern was transferred onto the patient by using a 3D printed template. The resulting incision pattern needed minor modifications by the surgeon before the surgery was performed. Further research and validation are necessary to develop the virtual planning of desyndactylization procedures.

  4. The 'French Fry' VAC technique: hybridisation of traditional open wound NPWT with closed incision NPWT.

    Science.gov (United States)

    Chopra, Karan; Tadisina, Kashyap K; Singh, Devinder P

    2016-04-01

    Surgical site occurrences (SSO), specifically surgical site infections represent a significant burden in the US health care system. It has been hypothesised that postoperative dressing can help drive down SSO. We describe the successful use of a novel technique combining both closed incision and open negative pressure wound therapy in the management of a high-risk wound associated with lymphoedema of obesity. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  5. Femtosecond Fiber Lasers

    Science.gov (United States)

    Bock, Katherine J.

    This thesis focuses on research I have done on ytterbium-doped femtosecond fiber lasers. These lasers operate in the near infrared region, lasing at 1030 nm. This wavelength is particularly important in biomedical applications, which includes but is not limited to confocal microscopy and ablation for surgical incisions. Furthermore, fiber lasers are advantageous compared to solid state lasers in terms of their cost, form factor, and ease of use. Solid state lasers still dominate the market due to their comparatively high energy pulses. High energy pulse generation in fiber lasers is hindered by either optical wave breaking or by multipulsing. One of the main challenges for fiber lasers is to overcome these limitations to achieve high energy pulses. The motivation for the work done in this thesis is increasing the output pulse peak power and energy. The main idea of the work is that decreasing the nonlinearity that acts on the pulse inside the cavity will prevent optical wave breaking, and thus will generate higher energy pulses. By increasing the output energy, ytterbium-doped femtosecond fiber lasers can be competitive with solid state lasers which are used commonly in research. Although fiber lasers tend to lack the wavelength tuning ability of solid state lasers, many biomedical applications take advantage of the 1030 microm central wavelength of ytterbium-doped fiber lasers, so the major limiting factor of fiber lasers in this field is simply the output power. By increasing the output energy without resorting to external amplification, the cavity is optimized and cost can remain low and economical. During verification of the main idea, the cavity was examined for possible back-reflections and for components with narrow spectral bandwidths which may have contributed to the presence of multipulsing. Distinct cases of multipulsing, bound pulse and harmonic mode-locking, were observed and recorded as they may be of more interest in the future. The third

  6. DNA polymerase. beta. reaction with ultraviolet-irradiated DNA incised by correndonuclease

    Energy Technology Data Exchange (ETDEWEB)

    Nowak, R; Zarebska, Z [Instytut Onkologii, Warsaw (Poland); Zmudzka, B [Polska Akademia Nauk, Warsaw. Inst. Biochemii i Biofizyki

    1980-09-19

    Covalently closed circular Col E1 DNA was ultraviolet-irradiated with a dose of 60 J/m/sup 2/, thus introducing about 3.2 pyrimidine dimers per DNA molecule. Treatment of irradiated Col E1 DNA with Micrococcus luteus correndonuclease resulted, in the vicinity of pyrimidine dimers, in an average of 3.3 incisions per DNA molecule, and converted DNA to the open circular form. Incised Col E1 DNA stimulated no reaction with calf thymus DNA polymerase ..cap alpha.. but was recognized as a template by DNA polymerase ..beta... The latter enzyme incorporated about 1.6 molecules of dTMP (corresponding to 6 molecules of dNMP) per one correndonuclease incision. The length of the DNA polymerase ..beta.. product was comparable to the anticipated length of the DNA region within which the hydrogen bonds were disrupted owing to dimer formation. The enzyme required Mg/sup 2 +/ and four dNTPs for reaction and was resistant to N-ethylmaleimide or p-mercuribenzoate.

  7. The longitudinal epineural incision and complete nerve transection method for modeling sciatic nerve injury

    Directory of Open Access Journals (Sweden)

    Xing-long Cheng

    2015-01-01

    Full Text Available Injury severity, operative technique and nerve regeneration are important factors to consider when constructing a model of peripheral nerve injury. Here, we present a novel peripheral nerve injury model and compare it with the complete sciatic nerve transection method. In the experimental group, under a microscope, a 3-mm longitudinal incision was made in the epineurium of the sciatic nerve to reveal the nerve fibers, which were then transected. The small, longitudinal incision in the epineurium was then sutured closed, requiring no stump anastomosis. In the control group, the sciatic nerve was completely transected, and the epineurium was repaired by anastomosis. At 2 and 4 weeks after surgery, Wallerian degeneration was observed in both groups. In the experimental group, at 8 and 12 weeks after surgery, distinct medullary nerve fibers and axons were observed in the injured sciatic nerve. Regular, dense myelin sheaths were visible, as well as some scarring. By 12 weeks, the myelin sheaths were normal and intact, and a tight lamellar structure was observed. Functionally, limb movement and nerve conduction recovered in the injured region between 4 and 12 weeks. The present results demonstrate that longitudinal epineural incision with nerve transection can stably replicate a model of Sunderland grade IV peripheral nerve injury. Compared with the complete sciatic nerve transection model, our method reduced the difficulties of micromanipulation and surgery time, and resulted in good stump restoration, nerve regeneration, and functional recovery.

  8. Characteristics of Bone Injuries Resulting from Knife Wounds Incised with Different Forces.

    Science.gov (United States)

    Humphrey, Caitlin; Kumaratilake, Jaliya; Henneberg, Maciej

    2017-11-01

    The aim of this research was to experimentally determine the characteristics of incised bone wounds, which are commonly found in defense injuries. A specially constructed pivoting arm device was used to inflict wounds with controlled forces and direction. Five knives were selected to inflict the wounds on porcine forelimbs. Eight incised wounds were made per knife per force. A larger knife and a greater force caused longer and wider bone wounds. Comparisons of individual knives at the two forces produced varying results in the bone wounds. A correlation was seen between the force and the length (r = 0.69), width (r = 0.63), and depth (r = 0.57) of bone wounds. Serrated-edge and nonserrated knives can be distinguished from the appearance of the wound. The outcomes may be applicable in forensic investigations to ascertain the forces associated with incised wounds and identify the specific knife used. © 2017 American Academy of Forensic Sciences.

  9. Chemical weathering as a mechanism for the climatic control of bedrock river incision

    Science.gov (United States)

    Murphy, Brendan P.; Johnson, Joel P. L.; Gasparini, Nicole M.; Sklar, Leonard S.

    2016-04-01

    Feedbacks between climate, erosion and tectonics influence the rates of chemical weathering reactions, which can consume atmospheric CO2 and modulate global climate. However, quantitative predictions for the coupling of these feedbacks are limited because the specific mechanisms by which climate controls erosion are poorly understood. Here we show that climate-dependent chemical weathering controls the erodibility of bedrock-floored rivers across a rainfall gradient on the Big Island of Hawai‘i. Field data demonstrate that the physical strength of bedrock in streambeds varies with the degree of chemical weathering, which increases systematically with local rainfall rate. We find that incorporating the quantified relationships between local rainfall and erodibility into a commonly used river incision model is necessary to predict the rates and patterns of downcutting of these rivers. In contrast to using only precipitation-dependent river discharge to explain the climatic control of bedrock river incision, the mechanism of chemical weathering can explain strong coupling between local climate and river incision.

  10. Risk factors for an additional port in single-incision laparoscopic cholecystectomy in patients with cholecystitis.

    Science.gov (United States)

    Araki, Kenichiro; Shirabe, Ken; Watanabe, Akira; Kubo, Norio; Sasaki, Shigeru; Suzuki, Hideki; Asao, Takayuki; Kuwano, Hiroyuki

    2017-01-01

    Although single-incision laparoscopic cholecystectomy is now widely performed in patients with cholecystitis, some cases require an additional port to complete the procedure. In this study, we focused on risk factor of additional port in this surgery. We performed single-incision cholecystectomy in 75 patients with acute cholecystitis or after cholecystitis between 2010 and 2014 at Gunma University Hospital. Surgical indications followed the TG13 guidelines. Our standard procedure for single-incision cholecystectomy routinely uses two needlescopic devices. We used logistic regression analysis to identify the risk factors associated with use of an additional full-size port (5 or 10 mm). Surgical outcome was acceptable without biliary injury. Nine patients (12.0%) required an additional port, and one patient (1.3%) required conversion to open cholecystectomy because of severe adhesions around the cystic duct and common bile duct. In multivariate analysis, high C-reactive protein (CRP) values (>7.0 mg/dl) during cholecystitis attacks were significantly correlated with the need for an additional port (P = 0.009), with a sensitivity of 55.6%, specificity of 98.5%, and accuracy of 93.3%. This study indicated that the severe inflammation indicated by high CRP values during cholecystitis attacks predicts the need for an additional port. J. Med. Invest. 64: 245-249, August, 2017.

  11. Smaller incision size leads to higher predictability in microcoaxial cataract surgery.

    Science.gov (United States)

    Klamann, Matthias K J; Gonnermann, Johannes; Maier, Anna-Karina B; Torun, Necip; Bertelmann, Eckart

    2013-01-01

    The aim of the study was to compare the clinical outcomes of a 1.8 mm, 2.2 mm, and 2.75 mm microcoaxial cataract surgery system. METHODS. In this retrospective study, 129 eyes of 129 patients were included. Patients underwent phacoemulsification using a Stellaris system or an Infiniti system. The incision size was 1.8 mm, 2.2 mm, or 2.75 mm, respectively. Subjects were examined before surgery and 4 weeks after. The surgically induced astigmatism (SIA) was examined. The SIA in the 1.8 mm group was statistically lower compared to the 2.2 mm group (p=0.046) and the 2.75 mm group (p=0.017). There was no significant difference between the 2.2 mm group and the 2.75 mm group. With the use of appropriate support systems, 1.8 mm incisions appear to result in less SIA than 2.2 mm and 2.75 mm incisions. Advantages may arise from this, especially in the implantation of aspheric, toric, or multifocal lenses.

  12. Optical coherence tomography of the effects of stromal hydration on clear corneal incision architecture.

    Science.gov (United States)

    Calladine, Daniel; Tanner, Vaughan

    2009-08-01

    To evaluate the effects of stromal hydration on clear corneal incision (CCI) architecture immediately after surgery using anterior segment optical coherence tomography (AS-OCT). Department of Ophthalmology, Royal Berkshire Hospital, Reading, United Kingdom. Clear corneal incisions in adult eyes were examined using a Visante AS-OCT imaging system within 1 hour of surgery. Half the CCIs had stromal hydration with a balanced salt solution and half did not. Incisions were made with a 2.75 mm steel keratome. Intraocular pressure (IOP) was measured within 90 minutes after surgery. The CCI length and corneal thickness at the CCI site were measured using software built into the AS-OCT system. Thirty CCIs were evaluated. Stromal hydration significantly increased the measured CCI length (Pthe result of a trend toward increased corneal thickness at the CCI site with hydration (PThe mean CCI length was 1.69 mm +/- 0.27 (SD) (range 1.31 to 2.32 mm) with hydration and 1.51 +/- 0.23 mm (range 1.30 to 1.95 mm) without hydration. The mean IOP was 20.9 +/- 8.18 mm Hg and 15.8 +/- 8.20 mm Hg, respectively. The IOP tended to be higher with hydration (Pthe eye with a higher early postoperative IOP, showing the importance of taking stromal hydration into account when designing similar OCT studies of CCI architecture.

  13. No-Drain Single Incision Liposuction Pull-Through Technique for Gynecomastia.

    Science.gov (United States)

    Khalil, Ashraf A; Ibrahim, Amr; Afifi, Ahmed M

    2017-04-01

    Several different methods have been proposed for treatment of gynecomastia, depending on the amount of breast enlargement and skin redundancy. The liposuction pull-through technique has been proposed as an efficacious treatment for many gynecomastia cases. This work aims to study the outcome of this technique when applied as an outpatient procedure, without the use of drains and through a single incision. Fifty-two patients with bilateral gynecomastia without significant skin excess were included in this study. The liposuction pull-through technique was performed through a single incision just above the inframammary fold and without the use of drains. Patients were followed up for 6 months. The proposed technique was able to treat the gynecomastia in all patients, with a revision rate of 1.9% to remove residual glandular tissues. There were no seromas, hematomas, nipple distortion, permanent affection of nipple sensation or wound healing problems. The liposuction pull-through technique is an effective treatment for gynecomastia without significant skin redundancy. It combines the benefits of the direct excision of glandular tissues, with the minimally invasive nature of liposuction. Performing the procedure through a single incision without the use of drains and without general anesthesia is a safe alternative. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors http://www.springer.com/00266 .

  14. Gynecomastia: glandular-liposculpture through a single transaxillary one hole incision.

    Science.gov (United States)

    Lee, Yung Ki; Lee, Jun Hee; Kang, Sang Yoon

    2018-04-01

    Gynecomastia is characterized by the benign proliferation of breast tissue in men. Herein, we present a new method for the treatment of gynecomastia, using ultrasound-assisted liposuction with both conventional and reverse-cutting edge tip cannulas in combination with a pull-through lipectomy technique with pituitary forceps through a single transaxillary incision. Thirty patients were treated with this technique at the author's institution from January 2010 to January 2015. Ten patients were treated with conventional surgical excision of the glandular/fibrous breast tissue combined with liposuction through a periareolar incision before January 2010. Medical records, clinical photographs and linear analog scale scores were analyzed to compare the surgical results and complications. The patients were required to rate their cosmetic outcomes based on the linear analog scale with which they rated their own surgical results; the mean overall average score indicated a good or high level of satisfaction. There were no incidences of skin necrosis, hematoma, infection and scar contracture; however, one case each of seroma and nipple inversion did occur. Operative time was reduced overall using the new technique since it is relatively simple and straightforward. According to the evaluation by the four independent researchers, the patients treated with this new technique showed statistically significant improvements in scar and nipple-areolar complex (NAC) deformity compared to those who were treated using the conventional method. Glandular liposculpture through a single transaxillary incision is an efficient and safe technique that can provide aesthetically satisfying and consistent results.

  15. Distinction of infected and non-infected post-surgical incisions with In-111-WBC scintigraphy

    International Nuclear Information System (INIS)

    Abdel-Nabi, H.; Hinkle, G.H.; Olsen, J.O.

    1985-01-01

    To determine if In-111-WBCs scintigraphy can distinguish between healing and infection in post-surgical wounds, a prospective study was performed in patients with 3-14 day old surgical incisions. Eighteen patients (11 males and 7 females) were scanned 24 hrs after injection of 0.5 mCi of In-111 labeled autologous leukocytes. The scan findings were correlated with blood and/wound cultures results and diagnosis at time of discharge. Incisional uptake of In-111-WBCs was noted in 9 patients with infected surgical wounds and was absent in those 9 patients with non-infected surgical wounds. The results of the authors' study show that In-111-WBCs do not accumulate in non-infected surgical incisions. This confirms their previous findings in rats. The high specificity of In-111 leukocytes imaging makes it a valuable study in the evaluation of post-operative patients with suspected surgical wound infections. In-111 WBCs scintigraphy can distinguish between normal healing and infection at the site of recent (3-14 days) surgical incisions

  16. Disposable skin staplers for closure of linear gastrointestinal incisions in dogs.

    Science.gov (United States)

    Schwartz, Zeev; Coolman, Bradley R

    2018-02-01

    To report the clinical features and outcomes of linear gastrointestinal incisions closed with skin staples in dogs. Historical cohort study. 333 client-owned dogs. Medical records from 1 private referral hospital were searched for dogs that underwent gastrointestinal surgery between November 1999 and October 2015. Cases were included if skin staplers were used to close linear gastrointestinal incisions. Information regarding preoperative, surgical, and postoperative factors was collected. Complications were diagnosed in 8 of 245 (3.27%) dogs, including 3 of 245 (1.22%) dogs that died or were euthanized, 3 of 245 (1.22%) dogs with incisional dehiscence, and 2 of 245 (0.81%) dogs with attachment of a linear foreign body to the staples at the intestinal lumen. Dehiscence was noted at the enterotomy sites in 3 dogs at a mean time of 44 hours after surgery (SD ± 6.93). Two dogs presented with another linear foreign body that was attached to the staples in the intestinal lumen at postoperative days 24 and 42. The risk factors associated with incisional dehiscence included multiple gastrointestinal incisions performed in 1 surgery (χ 2 , P indication for surgical intervention, surgery location in the gastrointestinal tract, or surgeon experience and incisional dehiscence. Skin staplers provide safe and effective closure of gastrotomies, enterotomies, and colonotomies in dogs. This method is reliable, efficient, and affordable in the hands of veterinary surgeons with varying skill levels. © 2017 The American College of Veterinary Surgeons.

  17. Review of various liver retraction techniques in single incision laparoscopic surgery for the exposure of hiatus.

    Science.gov (United States)

    Palanivelu, Praveenraj; Patil, Kedar Pratap; Parthasarathi, Ramakrishnan; Viswambharan, Jaiganesh K; Senthilnathan, Palanisami; Palanivelu, Chinnusamy

    2015-01-01

    The main aspect of concern for upper GI procedures has been the retraction of the liver especially large left lobes as commonly encountered in Bariatric surgery. Not doing so would compromise the view of the hiatus, hence theoretically reducing the quality of the surgery and increasing the possibility of complications. The aim of this study was to review the various liver retraction techniques in single incision surgery being done at our institute and analyze them. A retrospective study of the various techniques and a subsequent analysis was made based on advantages and disadvantages of each method. Objectively a quantitative measure of hiatal exposure was done using a scoring system based on the grade of exposure after reviewing the surgical videos. From January 2011 to January 2013 total 104 patients underwent single incision surgery with the various liver retraction techniques with following grades of exposure -liver suspension tube technique with naso gastric tubing (2.11) and with corrugated drain (2.09) needlescopic method (1.2), Umbilical tape sling (1.95), crural stitch method (2.5). Needeloscopic method has the best grade of exposure and is the easiest to start with. The average time to create the liver retraction was 2.8 to 8.6 min.There was no procedure related morbidity or mortality. The mentioned liver retraction techniques are cost effective and easy to learn. We recommend using these techniques to have a good exposure of hiatus, without compromising the safety of surgery in single incision surgery.

  18. Results of Intraoperative Manual Cyclotorsion Compensation for Myopic Astigmatism in Patients Undergoing Small Incision Lenticule Extraction (SMILE).

    Science.gov (United States)

    Ganesh, Sri; Brar, Sheetal; Pawar, Archana

    2017-08-01

    To study the safety, efficacy, and outcomes of manual cyclotorsion compensation in small incision lenticule extraction (SMILE) for myopic astigmatism. Eligible patients with myopia from -1.00 to -10.00 diopters (D) spherical equivalent with a minimum astigmatism of 0.75 D undergoing SMILE were included. Intraoperative cyclotorsion compensation was performed by gently rotating the cone and aligning the 0° to 180° limbal marks with the horizontal axis of the reticule of the right eye piece of the microscope of the femtosecond laser after activating the suction. In this study, 81 left eyes from 81 patients were analyzed for vector analysis of astigmatism. The mean cyclotorsion was 5.64° ± 2.55° (range: 2° to 12°). No significant differences were found for surgically induced astigmatism, difference vector, angle of error (AE), correction index, magnitude of error, index of success (IOS), and flattening index between 2 weeks and 3 months postoperatively (P > .05). The eyes were categorized into low (≤ 1.50 D, n = 37) and high (> 1.50 D, n = 44) cylinder groups. At 3 months, intergroup analysis showed a comparable correction index of 0.97 for the low and 0.93 for the high cylinder groups, suggesting a slight undercorrection of 3% and 7%, respectively (P = .14). However, the AE and IOS were significantly lower in the high compared to the low cylinder group (P = .032 and .024 for AE and IOS, respectively), suggesting better alignment of the treatment in the high cylinder group. However, the mean uncorrected distance visual acuity of both groups was comparable (P = .21), suggesting good visual outcomes in the low cylinder group despite a less favorable IOS. Manual compensation may be a safe, feasible, and effective approach to refine the results of astigmatism with SMILE, especially in higher degrees of cylinders. [J Refract Surg. 2017;33(8):506-512.]. Copyright 2017, SLACK Incorporated.

  19. Three-dimensional ordered titanium dioxide-zirconium dioxide film-based microfluidic device for efficient on-chip phosphopeptide enrichment.

    Science.gov (United States)

    Zhao, De; He, Zhongyuan; Wang, Gang; Wang, Hongzhi; Zhang, Qinghong; Li, Yaogang

    2016-09-15

    Microfluidic technology plays a significant role in separating biomolecules, because of its miniaturization, integration, and automation. Introducing micro/nanostructured functional materials can improve the properties of microfluidic devices, and extend their application. Inverse opal has a three-dimensional ordered net-like structure. It possesses a large surface area and exhibits good mass transport, making it a good candidate for bio-separation. This study exploits inverse opal titanium dioxide-zirconium dioxide films for on-chip phosphopeptide enrichment. Titanium dioxide-zirconium dioxide inverse opal film-based microfluidic devices were constructed from templates of 270-, 340-, and 370-nm-diameter poly(methylmethacrylate) spheres. The phosphopeptide enrichments of these devices were determined by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. The device constructed from the 270-nm-diameter sphere template exhibited good comprehensive phosphopeptide enrichment, and was the best among these three devices. Because the size of opal template used in construction was the smallest, the inverse opal film therefore had the smallest pore sizes and the largest surface area. Enrichment by this device was also better than those of similar devices based on nanoparticle films and single component films. The titanium dioxide-zirconium dioxide inverse opal film-based device provides a promising approach for the efficient separation of various biomolecules. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. The ‘Grand Canyon’ of the Da'an River, Taiwan - Influences on Ultra-Rapid Incision and Knickpoint Propagation

    Science.gov (United States)

    Cook, K. L.; Suppe, J.

    2009-12-01

    The 1999 magnitude 7.6 Chi-Chi earthquake resulted in significant surface uplift along the rupture zone in western Taiwan. At northeastern-most end of the rupture zone, near the town of Cholan, motion on the Chelungpu fault was accommodated by growth of the Tungshi Anticline, resulting in up to 10m of surface uplift in the channel of the Da’an River. Where the river crosses the anticline, the zone of uplift is approximately 1 km wide, with a gently sloping downstream (western) limb about 400 m long and an abrupt upstream (eastern) limb less than 50 m long. The bedrock consists of the Pliocene Cholan Formation, composed of alternating sandstone, siltstone, and mudstone beds. The bedrock is quite weak and is also pervasively fractured, making it extremely easy to erode. In response to the 1999 uplift, the Da’an River has cut a dramatic gorge, with more than 20 m of incision over a very short period. The rapid pace of incision allows us to directly observe how factors such as lithology, structure, and discharge influence the evolution of an actively incising gorge. We use a series of aerial photographs to map out the development of the gorge since 1999. We monitor the more recent evolution of the system with RTK GPS surveys to measure channel profiles, laser rangefinder measurements of channel width, and terrestrial LIDAR surveys to quantify changes in the gorge walls. The channel can currently be divided into four segments: 1) A broad network of braided alluvial channels upstream of the gorge with an average slope of 1.5 cm/km, 2) A steep knickzone about 600 m long with an average slope of 2.7 cm/km, about 8 meters of ‘excess’ incision, and abundant bedrock in the channel, 3) A lower gorge zone with low slopes, averaging between 0.6 and 1.1 cm/km, a significant amount of aggradation, and relatively narrow width, as flow is confined to the incised gorge, and 4) A broad network of braided alluvial channels downstream of the gorge with an average slope of 1.5 cm

  1. Heat pump processes induced by laser radiation

    Science.gov (United States)

    Garbuny, M.; Henningsen, T.

    1980-01-01

    A carbon dioxide laser system was constructed for the demonstration of heat pump processes induced by laser radiation. The system consisted of a frequency doubling stage, a gas reaction cell with its vacuum and high purity gas supply system, and provisions to measure the temperature changes by pressure, or alternatively, by density changes. The theoretical considerations for the choice of designs and components are dicussed.

  2. Effect of Novel Quercetin Titanium Dioxide-Decorated Multi-Walled Carbon Nanotubes Nanocomposite on Bacillus subtilis Biofilm Development

    Directory of Open Access Journals (Sweden)

    Diana S. Raie

    2018-01-01

    Full Text Available The present work was targeted to design a surface against cell seeding and adhering of bacteria, Bacillus subtilis. A multi-walled carbon nanotube/titanium dioxide nano-power was produced via simple mixing of carbon nanotube and titanium dioxide nanoparticles during the sol-gel process followed by heat treatment. Successfully, quercetin was immobilized on the nanocomposite via physical adsorption to form a quercetin/multi-walled carbon nanotube/titanium dioxide nanocomposite. The adhesion of bacteria on the coated-slides was verified after 24 h using confocal laser-scanning microscopy. Results indicated that the quercetin/multi-walled carbon nanotube/titanium dioxide nanocomposite had more negativity and higher recovery by glass surfaces than its counterpart. Moreover, coating surfaces with the quercetin-modified nanocomposite lowered both hydrophilicity and surface-attached bacteria compared to surfaces coated with the multi-walled carbon nanotubes/titanium dioxide nanocomposite.

  3. Cervical and incisal marginal discrepancy in ceramic laminate veneering materials: A SEM analysis

    Directory of Open Access Journals (Sweden)

    Hemalatha Ranganathan

    2017-01-01

    Full Text Available Context: Marginal discrepancy influenced by the choice of processing material used for the ceramic laminate veneers needs to be explored further for better clinical application. Aims: This study aimed to evaluate the amount of cervical and incisal marginal discrepancy associated with different ceramic laminate veneering materials. Settings and Design: This was an experimental, single-blinded, in vitro trial. Subjects and Methods: Ten central incisors were prepared for laminate veneers with 2 mm uniform reduction and heavy chamfer finish line. Ceramic laminate veneers fabricated over the prepared teeth using four different processing materials were categorized into four groups as Group I - aluminous porcelain veneers, Group II - lithium disilicate ceramic veneers, Group III - lithium disilicate-leucite-based veneers, Group IV - zirconia-based ceramic veneers. The cervical and incisal marginal discrepancy was measured using a scanning electron microscope. Statistical Analysis Used: ANOVA and post hoc Tukey honest significant difference (HSD tests were used for statistical analysis. Results: The cervical and incisal marginal discrepancy for four groups was Group I - 114.6 ± 4.3 μm, 132.5 ± 6.5 μm, Group II - 86.1 ± 6.3 μm, 105.4 ± 5.3 μm, Group III - 71.4 ± 4.4 μm, 91.3 ± 4.7 μm, and Group IV - 123.1 ± 4.1 μm, 142.0 ± 5.4 μm. ANOVA and post hoc Tukey HSD tests observed a statistically significant difference between the four test specimens with regard to cervical marginal discrepancy. The cervical and incisal marginal discrepancy scored F = 243.408, P < 0.001 and F = 180.844, P < 0.001, respectively. Conclusion: This study concluded veneers fabricated using leucite reinforced lithium disilicate exhibited the least marginal discrepancy followed by lithium disilicate ceramic, aluminous porcelain, and zirconia-based ceramics. The marginal discrepancy was more in the incisal region than in the cervical region in all the groups.

  4. Incision and Landsliding Lead to Coupled Increase in Sediment Flux and Grain Size Export

    Science.gov (United States)

    Roda-Boluda, D. C.; Brooke, S.; D'Arcy, M. K.; Whittaker, A. C.; Armitage, J. J.

    2017-12-01

    The rates and grain sizes of sediment fluxes modulate the dynamics and timing of landscape response to tectonics, and dictate the depositional patterns of sediment in basins. Over the last decades, we have gained a good quantitative understanding on how sediment flux and grain size may affect incision and basin stratigraphy. However, we comparably still have limited knowledge on how these variables change with varying tectonic rates. To address this question, we have studied 152 catchments along 8 normal fault-bounded ranges in southern Italy, which are affected by varying fault slip rates and experiencing a transient response to tectonics. Using a data set of 38 new and published 10Be erosion rates, we calibrate a sediment flux predictive equation (BQART), in order to estimate catchment sediment fluxes. We demonstrate that long-term sediment flux is governed by fault slip rates and the tectonically-controlled transient incision, and that sediment flux estimates from the BQART, steady-state assumptions, and incised volumes are highly correlated. This is supported by our 10Be erosion rates, which are controlled by fault slip and incision rates, and the associated landsliding. Based on a new landslide inventory, we show that erosion rate differences are likely due to differences in incision-related landslide activity across these catchments, and that landslides are a major component of sediment fluxes. From a data set of >13000 grain size counts on hillslope grain size supply and fluvial sediment at catchment outlets, we observe that landslides deliver material 20-200% coarser than other sediment sources, and that this coarse supply has an impact on the grain size distributions being exported from the catchments. Combining our sediment flux and grain size data sets, we are able to show that for our catchments, and potentially also for any areas that respond to changes in climate or tectonics via enhanced landsliding, sediment flux and grain size export increase

  5. High transverse skin incisions may reduce wound complications in obese women having cesarean sections: a pilot study.

    Science.gov (United States)

    Walton, Robert B; Shnaekel, Kelsey L; Ounpraseuth, Songthip T; Napolitano, Peter G; Magann, Everett F

    2017-11-01

    Women having cesarean section have a high risk of wound complications. Our objective was to determine whether high transverse skin incisions are associated with a reduced risk of cesarean wound complications in women with BMI greater than 40. A retrospective cohort study was undertaken of parturients ages 18-45 with BMI greater than 40 having high transverse skin incisions from January 2010 to April 2015 at a tertiary maternity hospital. Temporally matched controls had low transverse skin incisions along with a BMI greater than 40. The primary outcome, wound complication, was defined as any seroma, hematoma, dehiscence, or infection requiring opening and evacuating/debriding the wound. Secondary outcomes included rates of endometritis, number of hospital days, NICU admission, Apgar scores, birth weight, and gestational age at delivery. Analysis of outcomes was performed using two-sample t-test or Wilcoxon rank-sum test for continuous variables and Fisher's exact test for categorical variables. Thirty-two women had high transverse incisions and were temporally matched with 96 controls (low transverse incisions). The mean BMI was 49 for both groups. There was a trend toward reduced wound complications in those having high transverse skin incisions, but this did not reach statistical significance (15.63% versus 27.08%, p = .2379). Those having high transverse skin incisions had lower five minute median Apgar scores (8.0 versus 9.0, p = .0021), but no difference in umbilical artery pH values. The high transverse group also had increased NICU admissions (28.13% versus 5.21%, p = .0011), and early gestational age at delivery (36.8 versus 38.0, p = .0272). High transverse skin incisions may reduce the risk of wound complications in parturients with obesity. A study with more power should be considered.

  6. Carbon dioxide: emissions and effects

    Energy Technology Data Exchange (ETDEWEB)

    Smith, I M

    1982-01-01

    This review provides a comprehensive guide to work carried out since 1978 in the many disciplines involved in this complex issue. Possible scenarios for carbon dioxide emissions, sources and sinks in the carbon cycle and for climatic changes are examined. The current concensus (by no means unanimous) of specialists on this issue appears to be that a continuation of reduced trends in energy consumption since 1973 is likely to double the atmospheric carbon dioxide concentration to 600 ppmv during the latter part of the next century. However, a higher demand scenario, requiring an upper limit of coal production, would bring forward the doubling to about the middle of the next century. Current climatic models predict that such a concentration of carbon dioxide would cause an average global warming of from 1.0 to 4.5/sup 0/C which might be delayed by the thermal inertia of the oceans. A warming due to estimated increases in carbon dioxide should, if the model results are correct, become apparent at the end of this century. Regional climatic changes are likely to vary considerably and prove disadvantageous to some regions and beneficial to others. Different strategies for dealing with the carbon dioxide issue are considered: no response, alleviation, countermeasures and prevention. It is concluded that uncertainties do not justify either the use of carbon dioxide disposal and other technical fixes at present or a policy of no further growth in fossil fuel consumption. On the other hand, major efforts to conserve energy would give more time to adapt to changes. The alleviation of climatic impacts and other desirable dual-benefit measures are advocated in addition to continuing international, interdisciplinary research on all aspects.

  7. Laser-activated nano-biomaterials for tissue repair and controlled drug release

    International Nuclear Information System (INIS)

    Matteini, P; Ratto, F; Rossi, F; Pini, R

    2014-01-01

    We present recent achievements of minimally invasive welding of biological tissue and controlled drug release based on laser-activated nano-biomaterials. In particular, we consider new advancements in the biomedical application of near-IR absorbing gold nano-chromophores as an original solution for the photothermal repair of surgical incisions and as nanotriggers of controlled drug release from hybrid biopolymer scaffolds. (laser biophotonics)

  8. Comparison of diode laser and Er:YAG lasers in the treatment of ankyloglossia.

    Science.gov (United States)

    Aras, Mutan Hamdi; Göregen, Mustafa; Güngörmüş, Metin; Akgül, Hayati Murat

    2010-04-01

    The purpose of this study was to compare the tolerance of lingual frenectomy with regard to a local anesthesia requirement and comparison of postsurgical discomfort experienced by patients operated on with both diode and erbium:yttrium-aluminium-garnet (Er:YAG) lasers. Ankyloglossia, commonly known as tongue-tie, is a congenital oral anomaly characterized by a short lingual frenulum. A short lingual frenulum may contribute to feeding, speech, and mechanical tongue problems. Sixteen referred patients with tongue mobility complaints were included in this study. A GaAlAs laser device with a continuous wavelength of 808 nm was used in the diode group. Frenulums were incised by applying 2 W of laser power. The Er:YAG laser device with a continuous wavelength of 2940 nm was used in the Er:YAG group. Frenulums were incised by applying 1 W of laser power. The acceptability of the lingual frenectomy without local anesthesia and the degree of the postsurgical discomfort were evaluated. Although the majority of patients (six) could be operated on without local anesthesia in the Er:YAG group, all patients could not be operated on without local anesthetic agent in the diode group. There were no differences between the two groups with regard to pain, chewing, and speaking on the first or seventh day after surgery, whereas patients had more pain in the Er:YAG group than in the diode group the first 3 h after surgery. The results indicate that only the Er:YAG laser can be used for lingual frenectomy without local anesthesia, and there was no difference between the two groups regarding the degree of the postsurgical discomfort except in the first 3 h. In conclusion, these results indicate that the Er:YAG laser is more advantageous than the diode laser in minor soft-tissue surgery because it can be performed without local anesthesia and with only topical anesthesia.

  9. Carbon Dioxide Absorption Heat Pump

    Science.gov (United States)

    Jones, Jack A. (Inventor)

    2002-01-01

    A carbon dioxide absorption heat pump cycle is disclosed using a high pressure stage and a super-critical cooling stage to provide a non-toxic system. Using carbon dioxide gas as the working fluid in the system, the present invention desorbs the CO2 from an absorbent and cools the gas in the super-critical state to deliver heat thereby. The cooled CO2 gas is then expanded thereby providing cooling and is returned to an absorber for further cycling. Strategic use of heat exchangers can increase the efficiency and performance of the system.

  10. Three-dimensional observations of the incisive canal and the surrounding bone using cone-beam computed tomography

    International Nuclear Information System (INIS)

    Asaumi, Rieko; Kawai, Taisuke; Sato, Iwao; Yoshida, Shunji; Yosue, Takashi

    2010-01-01

    The shape of the anterior region of the maxilla is critical when planning implant treatment. The purpose of the present study was to assess the typical morphology of the incisive canal and surrounding bone. In total, 70 maxillae of Japanese dry skulls were used after being divided into dentate and edentulous groups. Cone-beam computed tomography (CBCT) images of the maxilla were acquired by using standardized methods. Using the anterior nasal spine as a reference point, the change in position was measured and analyzed statistically. Also, three-dimensional (3-D) images of the incisive canal were classified into five subsets: cylinder, groove, penetration, bifurcation at the superior portion, and bifurcation at the inferior portion. The quantity of alveolar bone in the incisor region was greatly reduced from the alveolar ridge and labial surface. Moreover, the vertical position of the incisive foramen was significantly (P<0.05) superior in the edentulous groups. Regarding the classification of maxillae by the 3-D shape of the incisive canal, many canals were cylindrical. Horizontal bone reduction from the labial side and vertical bone reduction from the alveolar crest were conspicuous; thus, the angle of the anterior alveolar bone changed after the loss of teeth. The incisive canal diameter in the edentulous group was larger than in the dentate group. The nondestructive assessment of the incisive canals and surrounding bone with CBCT showed two typical shapes for the presence or absence of the incisors. These findings indicate the importance of image diagnosis before esthetic restoration. (author)

  11. [EFFECTIVENESS OF ADVANCED SKIN FLAP AND V-SHAPED VENTRAL INCISION ALONG THE ROOT OF PENILE SHAFT FOR CONCEALED PENIS].

    Science.gov (United States)

    Lin, Junshan; Li, Dumiao; Zhang, Jianxing; Wu, Qiang; Xu, Yali; Lin, Li

    2015-09-01

    To investigate effectiveness of advanced skin flap and V-shaped ventral incision along the root of penile shaft for concealed penis in children. Between July 2007 and January 2015, 121 boys with concealed penis were treated with advanced skin flap and V-shaped ventral incision along the root of penile shaft. The age varied from 18 months to 13 years (mean, 7.2 years). Repair was based on a vertical incision in median raphe, complete degloving of penis and tacking its base to the dermis of the skin. Advanced skin flap and a V-shaped ventral incision along the root of penile shaft were used to cover the penile shaft. The operation time ranged from 60 to 100 minutes (mean, 75 minutes). Disruption of wound occurred in 1 case, and was cured after dressing change; and primary healing of incision was obtained in the others. The follow-up period ranged from 3 months to 7 years (median, 24 months). All patients achieved good to excellent cosmetic results with a low incidence of complications. The results were satisfactory in exposure of penis and prepuce appearance. No obvious scar was observed. The penis had similar appearance to that after prepuce circumcision. A combination of advanced skin flap and V-shaped ventral incision along the root of penile shaft is a simple, safe, and effective procedure for concealed penis with a similar appearance result to the prepuce circumcision.

  12. Stratigraphic architecture of back-filled incised-valley systems: Pennsylvanian-Permian lower Cutler beds, Utah, USA

    Science.gov (United States)

    Wakefield, Oliver J. W.; Mountney, Nigel P.

    2013-12-01

    The Pennsylvanian to Permian lower Cutler beds collectively form the lowermost stratigraphic unit of the Cutler Group in the Paradox Basin, southeast Utah. The lower Cutler beds represent a tripartite succession comprising lithofacies assemblages of aeolian, fluvial and shallow-marine origin, in near equal proportion. The succession results from a series of transgressive-regressive cycles, driven by repeated episodes of climatic variation and linked changes in relative sea-level. Relative sea-level changes created a number of incised-valleys, each forming through fluvial incision during lowered base-level. Aeolian dominance during periods of relative sea-level lowstand aids incised-valley identification as the erosive bounding surface juxtaposes incised-valley infill against stacked aeolian faces. Relative sea-level rises resulted in back-flooding of the incised-valleys and their infill via shallow-marine and estuarine processes. Back-flooded valleys generated marine embayments within which additional local accommodation was exploited. Back-filling is characterised by a distinctive suite of lithofacies arranged into a lowermost, basal fill of fluvial channel and floodplain architectural elements, passing upwards into barform elements with indicators of tidal influence, including inclined heterolithic strata and reactivation surfaces. The incised-valley fills are capped by laterally extensive and continuous marine limestone elements that record the drowning of the valleys and, ultimately, flooding and accumulation across surrounding interfluves (transgressive surface). Limestone elements are characterised by an open-marine fauna and represent the preserved expression of maximum transgression.

  13. Carbon Dioxide Embolism during Laparoscopic Surgery

    Science.gov (United States)

    Park, Eun Young; Kwon, Ja-Young

    2012-01-01

    Clinically significant carbon dioxide embolism is a rare but potentially fatal complication of anesthesia administered during laparoscopic surgery. Its most common cause is inadvertent injection of carbon dioxide into a large vein, artery or solid organ. This error usually occurs during or shortly after insufflation of carbon dioxide into the body cavity, but may result from direct intravascular insufflation of carbon dioxide during surgery. Clinical presentation of carbon dioxide embolism ranges from asymptomatic to neurologic injury, cardiovascular collapse or even death, which is dependent on the rate and volume of carbon dioxide entrapment and the patient's condition. We reviewed extensive literature regarding carbon dioxide embolism in detail and set out to describe the complication from background to treatment. We hope that the present work will improve our understanding of carbon dioxide embolism during laparoscopic surgery. PMID:22476987

  14. Hodgkin's disease following thorium dioxide angiography

    Energy Technology Data Exchange (ETDEWEB)

    Gotlieb, A I; Kirk, M E [McGill Univ., Montreal, Quebec (Canada). Dept. of Pathology; Hutchison, J L [Montreal General Hospital, Quebec (Canada)

    1976-09-04

    Hodgkin's disease occurred in a 53-year-old man who, 25 years previously, had undergone cerebral angiography, for which thorium dioxide suspension (Thorotrast) was used. Deposits of thorium dioxide were noted in reticuloendothelial cells in various locations. An association between thorium dioxide administration and the subsequent development of malignant tumours and neoplastic hematologic disorders has previously been reported.

  15. 21 CFR 582.1240 - Carbon dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 6 2010-04-01 2010-04-01 false Carbon dioxide. 582.1240 Section 582.1240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) ANIMAL DRUGS....1240 Carbon dioxide. (a) Product. Carbon dioxide. (b) Conditions of use. This substance is generally...

  16. 21 CFR 73.1575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.1575 Section 73.1575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1575 Titanium dioxide. (a) Identity and specifications. (1) The color additive titanium dioxide shall conform in identity and specifications to the requirements...

  17. 40 CFR 180.1195 - Titanium dioxide.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Titanium dioxide. 180.1195 Section 180.1195 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS... Titanium dioxide. Titanium dioxide is exempted from the requirement of a tolerance for residues in or on...

  18. 21 CFR 73.2575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.2575 Section 73.2575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Cosmetics § 73.2575 Titanium dioxide. (a) Identity and specifications. The color additive titanium dioxide shall conform in identity and specifications to the requirements...

  19. 21 CFR 73.575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.575 Section 73.575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Foods § 73.575 Titanium dioxide. (a) Identity. (1) The color additive titanium dioxide is synthetically prepared TiO2, free from admixture with other substances. (2) Color...

  20. 21 CFR 73.3126 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.3126 Section 73.3126 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Medical Devices § 73.3126 Titanium dioxide. (a) Identity and specifications. The color additive titanium dioxide (CAS Reg. No. 13463-67-7), Color Index No. 77891, shall...

  1. Radiation induced sulfur dioxide removal

    International Nuclear Information System (INIS)

    Chmielewski, A.G.

    2000-01-01

    The biggest source of air pollution is the combustion of fossil fuels, were pollutants such as particulate, sulfur dioxide (SO 2 ), nitrogen oxides (NO x ), and volatile organic compounds (VOC) are emitted. Among these pollutants, sulfur dioxide plays the main role in acidification of the environment. The mechanism of sulfur dioxide transformation in the environment is partly photochemical. This is not direct photooxidation, however, but oxidation through formed radicals. Heterogenic reactions play an important role in this transformation as well; therefore, observations from environmental chemistry can be used in air pollution control engineering. One of the most promising technologies for desulfurization of the flue gases (and simultaneous denitrification) is radiation technology with an electron accelerator application. Contrary to the nitrogen oxides (NO x ) removal processes, which is based on pure radiation induced reactions, sulfur dioxide removal depends on two pathways: a thermochemical reaction in the presence of ammonia/water vapor and a radiation set of radiochemical reactions. The mechanism of these reactions and the consequent technological parameters of the process are discussed in this paper. The industrial application of this radiation technology is being implemented in an industrial pilot plant operated by INCT at EPS Kaweczyn. A full-scale industrial plant is currently in operation in China, and two others are under development in Japan and Poland. (author)

  2. Modelling Sublimation of Carbon Dioxide

    Science.gov (United States)

    Winkel, Brian

    2012-01-01

    In this article, the author reports results in their efforts to model sublimation of carbon dioxide and the associated kinetics order and parameter estimation issues in their model. They have offered the reader two sets of data and several approaches to determine the rate of sublimation of a piece of solid dry ice. They presented several models…

  3. Thermal conductivity of uranium dioxide

    International Nuclear Information System (INIS)

    Pillai, C.G.S.; George, A.M.

    1993-01-01

    The thermal conductivity of uranium dioxide of composition UO 2.015 was measured from 300 to 1400 K. The phonon component of the conductivity is found to be quantitatively accounted for by the theoretical expression of Slack derived by modifying the Leibfried-Schlomann equation. (orig.)

  4. Water table and overbank flow frequency changes due to suburbanization-induced channel incision, Virginia Coastal Plain, USA

    Science.gov (United States)

    Hancock, G.; Mattell, N.; Christianson, E.; Wacksman, J.

    2004-12-01

    Channel incision is a widely observed response to increased flow in urbanized watersheds, but the effects of channel lowering on riparian water tables is not well documented. In a rapidly incising suburban stream in the Virginia Coastal Plain, we hypothesize that incision has lowered floodplain water tables and decreased the overbank flow frequency, and suggest these changes impact vegetation distribution in a diverse, protected riparian habitat. The monitored stream is a tributary to the James River draining 1.3 km2, of which 15% is impervious cover. Incision has occurred largely through upstream migration of a one m high knickpoint at a rate of 1-2 m/yr, primarily during high flow events. We installed 33 wells in six floodplain transects to assess water table elevations beneath the floodplain adjacent to the incising stream. To document the impacts of incision, two transects are located 30 and 50 m upstream of the knickpoint in unincised floodplain, and the remainder are 5, 30, 70, and 100 m downstream of the knickpoint in incised floodplain. In one transect above and two below, pressure transducers attached to dataloggers provide a high-resolution record of water table response to storm events. Significant differences have been observed in the water table above and below the knickpoint. Above the knickpoint, the water table is relatively flat and is 0.2-0.4 m below the floodplain surface. Water table response to precipitation events is nearly immediate, with the water table rising to the floodplain surface in significant rainfall events. In the transect immediately downstream of the knickpoint, the water table possesses a steep gradient, rising from ~1 m below the floodplain at the stream to 0.3 m below the surface within 20 m. In the most downstream transects, the water table is relatively flat, but is one m below the floodplain surface, equivalent to the depth of incision generated by knickpoint passage. Upstream of the knickpoint, overbank flooding occurs

  5. Transverse Skin Crease versus Vertical Midline Incision versus Laparoscopy for Right Hemicolectomy: A Systematic Review—Current Status of Right Hemicolectomy

    Directory of Open Access Journals (Sweden)

    Alberto Santoro

    2014-01-01

    Full Text Available Purpose. The right hemicolectomy may be conducted through laparoscopic or laparotomic surgery, transverse or midline incisions. The transverse laparotomy offers some advantages compared to the midline laparotomy and laparoscopy. A literature review was performed to evaluate the possible advantages of the transverse incision versus midline incision or laparoscopic right hemicolectomy. Methods. A systematic research was performed in Medline, Embase, Cochrane Central Register of Controlled Trials, CINAHL, BioMed Central, and the Science Citation Index. Results. Laparotomic right hemicolectomy with transverse incision is preferable to laparotomic hemicolectomy with midline incision. A transverse incision offers a lessened postoperative pain following physical activity, a lessened need to administer analgesic therapy during the post-operative time, better aesthetic results, and a better post-operative pulmonary function. Open surgery with transverse or midline incision ensured a shorter operative time, lower costs and a greater length of the incision compared to the laparoscopic. However, there are no differences in the oncological outcomes. Conclusions. It was not possible to identify significant differences between the open right hemicolectomy with transverse incision versus the open right hemicolectomy with midline incision or laparoscopic hemicolectomy.

  6. [Antero-medial incision of knee joint for the treatment of intercondylar fracture of femur].

    Science.gov (United States)

    Yin, Zi-Fei; Sun, Bin-Feng; Yang, Xiao-Hai; Wang, Qing; Qian, Ping-Kang; Wu, Xiao-Feng; Xu, Feng

    2017-12-25

    To explore the clinical effect of antero-medial incision of knee joint in treating intercondylar fracture of femur. From September 2012 to March 2015, 24 patients with intercondylar fracture of femur were selected, including 17 males and 7 females, aged from 20 to 65 years old with an average of(38.3±9.5) years old. Among them, 12 cases were caused by traffic accident, 8 cases were caused by falling injury and 4 cases were caused by falling down. All patients were closed fractures. The time from injury to hospital was from 30 min to 8 h with an average of(2.2±0.3) h. According to AO classification, 4 cases were type B1, 3 type B2, 2 type B3, 5 type C1, 6 type C2 and 4 type C3. All patients were treated with antero-medial incision of knee joint. Operative time, blood loss and postoperative complications were observed and recovery of keen function was evaluated by Kolmert scoring. All patients were followed-up from 6 to 12 months with average of (9.0±1.7) months. Operative time ranged from 50 to 90 min with an average of (70.0±8.2) min; blood loss ranged from 90 to 400 ml with an average of (180±36) ml; negative pressure flow was from 30 to 90 ml, with an average of (50.0±7.1) ml. All fracture were healed at stage I without loosening of internal fixator, fracture nonunion, and deep vein thrombosis. According to Kolmert scoring, 16 patients got excellent result, 5 patients good and 3 fair. Antero-medial incision of knee joint in treating intercondylar fracture of femur, which has advantages of good fracture reduction, less injury of soft tissue and simple operation, could obtain good clinical results.

  7. Incisal tooth wear and self-reported TMD pain in children and adolescents.

    Science.gov (United States)

    Hirsch, Christian; John, Mike T; Lobbezoo, Frank; Setz, Juergen M; Schaller, Hans-Guenter

    2004-01-01

    Incisal tooth wear may be a sign of long-term bruxing behavior. Bruxism is purported to be a risk factor for temporomandibular disorders (TMD). The aim of this population-based cross-sectional study was to determine if anterior tooth wear is associated with the self-report of TMD pain in children and adolescents. In a population sample of 1,011 children and adolescents (mean age 13.1 years, range 10 to 18 years; female 52%; response rate 85%), TMD cases were defined as subjects reporting pain in the face, jaw muscles, and temporomandibular joint during the last month according to RDC/TMD. All other subjects were considered controls. Incisal tooth wear was assessed in the clinical examination using a 0 to 2 scale (no wear, enamel wear, dentin wear) for every anterior permanent tooth. The mean wear score for the individuals was categorized into 0, 0.01 to 0.20, 0.21 to 0.40, and 0.41+. A multiple logistic regression analysis, controlling for the effects of age and gender, analyzed the association between the categorized summary wear score and TMD. Specifically, the hypothesis of a trend between higher tooth wear scores and higher risk of TMD was tested. An odds ratio of 1.1 indicated, after adjusting for gender and age, no statistically significantly higher risk of TMD pain with higher tooth wear scores. Incisal tooth wear was not associated with self-reported TMD pain in 10- to 18-year-old subjects.