WorldWideScience

Sample records for dimensional power doppler

  1. Power Doppler flow mapping and four-dimensional ultrasound for evaluating tubal patency compared with laparoscopy.

    Science.gov (United States)

    Soliman, Amr A; Shaalan, Waleed; Abdel-Dayem, Tamer; Awad, Elsayed Elbadawy; Elkassar, Yasser; Lüdders, Dörte; Malik, Eduard; Sallam, Hassan N

    2015-12-01

    To study the accuracy of four-dimensional (4D) ultrasound and power Doppler flow mapping in detecting tubal patency in women with sub-/infertility, and compare it with laparoscopy and chromopertubation. A prospective study. The study was performed in the outpatient clinic and infertility unit of a university hospital. The sonographic team and laparoscopic team were blinded to the results of each other. Women aged younger than 43 years seeking medical advice due to primary or secondary infertility and who planned to have a diagnostic laparoscopy performed, were recruited to the study after signing an informed consent. All of the recruited patients had power Doppler flow mapping and 4D hysterosalpingo-sonography by injecting sterile saline into the fallopian tubes 1 day before surgery. Registering Doppler signals, while using power Doppler, both at the tubal ostia and fimbrial end and the ability to demonstrate the course of the tube especially the isthmus and fimbrial end, while using 4D mode, was considered a patent tube. Out of 50 recruited patients, 33 women had bilateral patent tubes and five had unilateral patent tubes as shown by chromopertubation during diagnostic laparoscopy. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy for two-dimensional power Doppler hysterosalpingography were 94.4%, 100%, 100%, 89.2%, and 96.2%, respectively and for 4D ultrasound were 70.4%, 100%, 100%, 70.4%, and 82.6%, respectively. Four-dimensional saline hysterosalpingography has acceptable accuracy in detecting tubal patency, but is surpassed by power Doppler saline hysterosalpingography. Power Doppler saline hysterosalpingography could be incorporated into the routine sub-/infertility workup. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  3. Accuracy of Gray‑scale and Three‑dimensional Power Doppler ...

    African Journals Online (AJOL)

    Background: Morbidly adherent placenta (MAP) is usually associated with excess blood loss, bladder injuries, and hysterectomies. Aim: This study was designed to evaluate the accuracy of grayscale and three-dimensional (3D) power Doppler ultrasound parameters in the diagnosis of MAP. Subjects and Methods: Fifty ...

  4. Three-dimensional power Doppler sonography: imaging and quantifying blood flow and vascularization.

    Science.gov (United States)

    Pairleitner, H; Steiner, H; Hasenoehrl, G; Staudach, A

    1999-08-01

    To assess the feasibility of imaging low-velocity blood flow in adnexal masses by transvaginal three-dimensional power Doppler sonography, to analyze three-dimensional power Doppler sonography data sets with a new computer-assisted method and to test the reproducibility of the technique. A commercially available 5-MHz Combison 530 ultrasound system was used to perform three-dimensional power Doppler sonography transvaginally. A cube (= volume of interest) was defined enclosing the vessels of the cyst and the Cartesian characteristics were stored on a hard disk. This cube was analyzed using specially designed software. Five indices representing vascularization (the vascularization index (VI) or blood flow (the flow index (FI)) or both (the vascularization-flow index (VFI)) were calculated. The intraobserver repeatability of cube definition and scan repetition was assessed using Hartley's test for homogeneous variances. Interobserver agreement was assessed by the Pearson correlation coefficient. Imaging of vessels with low-velocity blood flow by three-dimensional power Doppler sonography and cube definition was possible in all adnexal massed studied. In some cases even induced non-vascular flow related to endometriosis was detected. The calculated F value with intraobserver repeated Cartesian file-saving ranged from 0 to 18.8, with intraobserver scan repetition from 4.74 to 24.8 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the calculated F value was 64. The interobserver correlation coefficient ranged between 0.83 and 0.92 for VI, FI 1, FI 2 and VFI 1; for VFI 2 the correlation coefficient was less than 0.75. Vessels with low-velocity blood flow can be imaged using three-dimensional power Doppler sonography. Induced non-vascular flow was detected in endometriotic cyst fluid. Three-dimensional power Doppler sonography combined with the cube method gave reproducible information for all indices except VFI 2. These indices might prove to be a new predictor in all fields of

  5. Assessment of cerebral circulation in normal fetuses by three-dimensional power Doppler ultrasonography

    International Nuclear Information System (INIS)

    Milani, Hérbene José Figuinha; Sá Barreto, Enoch Quinderé de; Araujo Júnior, Edward; Haratz, Karina Krajden; Rolo, Liliam Cristine; Nardozza, Luciano Marcondes Machado; Moron, Antonio Fernandes

    2012-01-01

    Objective: To assess the three-dimensional power Doppler ultrasonography (3D power Doppler) vascular indices in the middle cerebral artery (MCA), anterior cerebral artery (ACA) and posterior cerebral artery (PCA) territories. Methods: A cross-sectional study was carried out on 111 normal pregnancies between 26 and 34 weeks. The MCA, ACA and PCA territories closest to the transducer were scanned and volumes were calculated by using the VOCAL (Virtual Organ Computer-aided Analysis) program. The 3D power Doppler indices – vascularization index (VI), flow index (FI) and vascularization-flow index (VFI) were calculated. Scatter graphs, Pearson correlation coefficients (r) and linear regression models were used. Results: Only the FI-MCA (r = 0.38 and p < 0.001), VFI-MCA (r = 0.23 and p = 0.016) and FI-PCA (r = 0.191 and p = 0.040) had a low correlation with gestational age. The other 3D power Doppler indices VI-MCA (r = 0.153 and p = 0.150), VI-ACA (r = 0.105 and p = 0.271), FI-ACA (r = 0.154 and p = 0.106), VFI-ACA (r = 0.134 and p = 0.161), VI-PCA (r = 0.105 and p = 0.270) and VFI-PCA (r = 0.126 and p = 0.180) showed no statistically significant correlation with gestational. Conclusion: It was observed a low correlation between gestational age and the FI-MCA, VFI-MCA and FI-PCA.

  6. Placental three-dimensional power Doppler indices in mid-pregnancy and late pregnancy complicated by gestational diabetes mellitus.

    Science.gov (United States)

    Surányi, A; Kozinszky, Z; Molnár, A; Nyári, T; Bitó, T; Pál, A

    2013-10-01

    The aim of our study was to evaluate placental three-dimensional power Doppler indices in diabetic pregnancies in the second and third trimesters and to compare them with those of the normal controls. Placental vascularization of pregnant women was determined by three-dimensional power Doppler ultrasound technique. The calculated indices included vascularization index (VI), flow index (FI), and vascularization flow index (VFI). Uncomplicated pregnancies (n = 113) were compared with pregnancies complicated by gestational diabetes mellitus (n = 56) and diabetes mellitus (n = 43). The three-dimensional power Doppler indices were not significantly different between the two diabetic subgroups. All the indices in diabetic patients were significantly reduced compared with those in non-diabetic individuals (p power Doppler indices are slightly diminished throughout diabetic pregnancy [regression coefficients: -0.23 (FI), -0.06 (VI), and -0.04 (VFI)] and normal pregnancy [regression coefficients: -0.13 (FI), -0.20 (VI), and -0.11 (VFI)]. The uteroplacental circulation (umbilical and uterine artery) was not correlated significantly to the three-dimensional power Doppler indices. If all placental indices are low during late pregnancy, then the odds of the diabetes are significantly high (adjusted odds ratio: 1.10). A decreased placental vascularization could be an adjunct sonographic marker in the diagnosis of diabetic pregnancy in mid-gestation and late gestation. © 2013 John Wiley & Sons, Ltd.

  7. Use of translabial three-dimensional power Doppler ultrasound for cervical assessment before labor induction.

    Science.gov (United States)

    Esin, Sertac; Yirci, Bulent; Yalvac, Serdar; Kandemir, Omer

    2017-07-26

    To compare translabial three-dimensional (3D) power Doppler ultrasound with Bishop score and transvaginal ultrasound measurements for cervical assessment before induction of labor with dinoprostone or cervical ripening balloon. Translabial cervical volume and length, vascularization indices and transvaginal cervical length were measured. Results were compared among women who had vaginal delivery at 24 h or less and more than 24 h after the insertion of the dinoprostone vaginal insert or cervical ripening balloon and among women who had vaginal delivery and cesarean delivery for failure to go into labor or failure to progress. There was no correlation between the time to delivery after a ripening agent was applied and translabial cervical volume, translabial cervical length, vascularization index (VI), flow index (FI), vascularization flow index (VFI), transvaginal cervical length and Bishop scores. The ultrasonographic measurements were no different among women who had vaginal delivery at 24 h or less and more than 24 h and among women who had vaginal delivery and cesarean delivery for failure to go into labor or failure to progress. In this study, we failed to demonstrate the superiority of translabial 3D ultrasonography over Bishop score and transvaginal ultrasonography for predicting the success of induction of labor.

  8. Accuracy of Gray-scale and Three-dimensional Power Doppler ...

    African Journals Online (AJOL)

    and Gynecology, Ahmadi Kuwait Oil Company Hospital, Ahmadi, Kuwait ... Subjects and Methods: Fifty pregnant women ≥28 weeks' gestation with suspected MAP were ... and build upon the work non‑commercially, as long as the author is credited and the ... 3D power Doppler images were analyzed using virtual organ.

  9. Diagnostic utility of three-dimensional power Doppler ultrasound for postmenopausal bleeding.

    Science.gov (United States)

    Kim, Ari; Lee, Ji Young; Chun, Sungwook; Kim, Heung Yeol

    2015-06-01

    We evaluated the role of three-dimensional power Doppler ultrasound (3D PD-US) to detect endometrial lesions in women with postmenopausal endometrial bleeding. In this prospective observational study, from January 2009 to November 2012, we recruited 225 postmenopausal women with postmenopausal uterine bleeding who met the study criteria. Women who had hematologic disease, chronic medical diseases, or nonuterine pelvic diseases were excluded. Prior to endometrial biopsy, the patients underwent a baseline transvaginal ultrasound screening. The vascular indices and endometrial volumes were calculated with 3D PD-US and compared with the endometrial histopathology. Among the endometrial histopathologic findings of 174 women, atrophic endometrium was the most common finding (30.5%). Endometrial malignancy was confirmed in 28 cases (16.1%), and endometrial hyperplasia was diagnosed in 17 cases (9.8%). The prevalence of endometrial cancer was high in patients who had endometrial thickness >9.5 mm (p < 0.001) and volume greater than 4.05 mL (p < 0.001). For the endometrial carcinoma only, the cutoff values of vascular index, flow index, and vascular flow index for predicting malignancy were 13.070, 12.610, and 3.764, respectively. For endometrial hyperplasia, endometrial thickness and vascular flow index were significant findings. Endometrial vasculature and volume can be obtained using 3D PD-US. The diagnostic usefulness of 3D PD-US for endometrial diseases is promising in women with postmenopausal endometrial bleeding. Copyright © 2015. Published by Elsevier B.V.

  10. The Contribution of Three-Dimensional Power Doppler Imaging in the Preoperative Assessment of Breast Tumors: A Preliminary Report

    Directory of Open Access Journals (Sweden)

    K. Kalmantis

    2009-01-01

    Methods. One hundred and twenty five women with clinically or mammographically suspicious findings were referred for 3D Power Doppler ultrasound prior to surgery. Histological diagnosis was conducted after surgery and compared with ultrasound findings. Sonographic criteria used for breast cancer diagnosis were based on a system that included morphological characteristics and criteria of the vascular pattern of a breast mass by Power Doppler imaging. Results. Seventy-two lesions were histopathologically diagnosed as benign and 53 tumors as malignant. Three-dimensional ultrasound identified 49 out of 53 histologically confirmed breast cancers resulting in a sensitivity of 92.4% and a specificity of 86.1% in diagnosing breast malignancy (PPV: 0.83, NPV:0.94. Conclusions. 3D ultrasonography is a valuable tool in identifying preoperatively the possibility of a tumor to be malignant.

  11. Two-dimensional power Doppler-three-dimensional ultrasound imaging of a cesarean section dehiscence with utero-peritoneal fistula: a case report

    Directory of Open Access Journals (Sweden)

    Royo Pedro

    2009-01-01

    Full Text Available Abstract Introduction An imaging diagnosis after an iterative cesarean delivery is reviewed demonstrating a fine ultrasound-pathologic correlation. Case presentation A 33-year-old woman (G3, P3 presented referring intense dysmenorrhea and intermenstrual spotting since her third cesarean delivery, 1 year before. A cesarean section dehiscence with utero-peritoneal fistula was diagnosed by transvaginal ultrasound. Conclusion We can conclude that transvaginal two-dimensional power Doppler and three-dimensional ultrasound are highly accurate in detecting cesarean section dehiscence and uterine fistula.

  12. Using Flow Characteristics in Three-Dimensional Power Doppler Ultrasound Imaging to Predict Complete Responses in Patients Undergoing Neoadjuvant Chemotherapy.

    Science.gov (United States)

    Shia, Wei-Chung; Huang, Yu-Len; Wu, Hwa-Koon; Chen, Dar-Ren

    2017-05-01

    Strategies are needed for the identification of a poor response to treatment and determination of appropriate chemotherapy strategies for patients in the early stages of neoadjuvant chemotherapy for breast cancer. We hypothesize that power Doppler ultrasound imaging can provide useful information on predicting response to neoadjuvant chemotherapy. The solid directional flow of vessels in breast tumors was used as a marker of pathologic complete responses (pCR) in patients undergoing neoadjuvant chemotherapy. Thirty-one breast cancer patients who received neoadjuvant chemotherapy and had tumors of 2 to 5 cm were recruited. Three-dimensional power Doppler ultrasound with high-definition flow imaging technology was used to acquire the indices of tumor blood flow/volume, and the chemotherapy response prediction was established, followed by support vector machine classification. The accuracy of pCR prediction before the first chemotherapy treatment was 83.87% (area under the ROC curve [AUC] = 0.6957). After the second chemotherapy treatment, the accuracy of was 87.9% (AUC = 0.756). Trend analysis showed that good and poor responders exhibited different trends in vascular flow during chemotherapy. This preliminary study demonstrates the feasibility of using the vascular flow in breast tumors to predict chemotherapeutic efficacy. © 2017 by the American Institute of Ultrasound in Medicine.

  13. Quantitative analysis of normal fetal medulla oblongata volume and flow by three-dimensional power Doppler ultrasound.

    Science.gov (United States)

    Shyu, Ing-Luen; Wang, Peng-Hui; Chen, Chih-Yao; Chen, Yi-Jen; Chang, Chia-Ming; Horng, Huann-Cheng; Yang, Ming-Jie; Yen, Ming-Shyen

    2016-06-01

    Assessment of the fetal medulla oblongata volume (MOV) and blood flow might be important in the evaluation of fetal brain growth. We used three-dimensional power Doppler ultrasound (3DPDUS) to assess the fetal MOV and blood flow index in normal gestation. The relationships between these parameters were further analyzed. We assessed the total volume and blood flow index of the fetal MO in normal pregnancies using a 3DPDUS (Voluson 730 Expert). The true sagittal plane over the fetal occipital area was measured by a 3D transabdominal probe to scan the fetal MO under the power Doppler mode. Then, we quantitatively assessed the total volume of the fetal MOV, mean gray area (MG), vascularization index (VI), and flow index (FI). A total of 106 fetuses, ranging from 19 weeks to 39 weeks of gestation, were involved in our study. The volume of the fetal MO was highly positively correlated with gestational age [correlation coefficient (r) = 0.686, p < 0.0001]. The MG was negatively correlated with gestational age [r = -0.544, p < 0.0001). VI and FI showed no significant correlation with gestational age (p = 0.123 and p = 0.219, respectively). 3DPDUS can be used to assess the fetal MOV and blood flow development quantitatively. Our study indicated that fetal MOV and blood flow correlated significantly with the advancement of gestational age. This information may serve as reference data for further studies of the fetal brain and blood flow under abnormal conditions. Copyright © 2016. Published by Elsevier B.V.

  14. Assessment by three-dimensional power Doppler ultrasound of cerebral blood flow perfusion in fetuses with congenital heart disease.

    Science.gov (United States)

    Zeng, S; Zhou, J; Peng, Q; Tian, L; Xu, G; Zhao, Y; Wang, T; Zhou, Q

    2015-06-01

    To use three-dimensional (3D) power Doppler ultrasound to investigate cerebral blood flow perfusion in fetuses with congenital heart disease (CHD). The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) in the total intracranial volume and the main arterial territories (middle cerebral artery (MCA), anterior cerebral artery (ACA) and posterior cerebral artery (PCA)) were evaluated prospectively and compared in 112 fetuses with CHD and 112 normal fetuses using 3D power Doppler. Correlations between the 3D power Doppler indices and neurodevelopment scores at 12 months of age were assessed in a subset of the CHD group, and values were compared with those of controls. Compared with the controls, the VI, FI and VFI of the total intracranial volume and the three main arteries were significantly higher in fetuses with hypoplastic left heart syndrome and left-sided obstructive lesions (P power Doppler values in the ACA territory were significantly higher in fetuses with transposition of the great arteries (P power Doppler ultrasound might help to identify cases of brain vasodilatation earlier and inform parental counseling. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  15. A Comparative Study on Quantitative Assessment of Blood Flow and Vascularization in Polycystic Ovary Syndrome Patients and Normal Women Using Three-Dimensional Power Doppler Ultrasonography.

    Science.gov (United States)

    Garg, Nitasha; Khaira, Harkiran Kaur; Kaur, Manjot; Sinha, Smita

    2018-04-01

    To compare the quantitative assessment of blood flow and vascularization of ovaries in polycystic ovary syndrome patients and normal women using three-dimensional power Doppler ultrasonography. This cross-sectional quantitative study was conducted on women of reproductive age group (15-45 years) attending Gynaecology OPD AIMSR, Bathinda, Punjab. Thirty women were enrolled in polycystic ovarian syndrome (PCOS) group and 30 healthy women in control group. Women were categorized as polycystic ovary syndrome according to Rotterdam's criteria. The women with PCOS underwent transvaginal USG Doppler on day 6 of the cycle using 3D power Doppler USG equipment (GE Voluson E8), and vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were measured. The mean values of VI, FI and VFI measured by power Doppler ultrasonography were significantly increased ( P value = 0.000) in women with PCOS when compared with healthy women. This study suggests that blood flow and vascularization measured by 3D power Doppler ultrasonography in ovaries of polycystic ovary syndrome patients were significantly more than the ovaries of normal women.

  16. [Examination of placental three-dimensional power Doppler indices and perinatal outcome in pregnancies complicated by intrauterine growth restriction].

    Science.gov (United States)

    Molnár, András; Surányi, Andrea; Jakó, Mária; Nyári, Tibor; Németh, Gábor

    2017-07-01

    Development of intrauterine growth restriction (IUGR) can be traced back to maternal or fetal factors, but in many cases we find placental factors (reduced placental circulation) in the background. Our aim was to examine whether the reduced placental bloodperfusion and vascularity show any correlation with cesarean section frequency and the clinical outcome in IUGR pregnancies. The aim of the present study was also to use a properly calibrated and reproducible method for evaluating placental blood flow, that can later be incorporated into the routine examination. 254 women were recruited in our prospective case-control study. The 3 dimensional power Doppler (3DPD) ultrasound indices; vascularisation index (VI), flow index (FI) and vascularization flow index (VFI) were measured on each participant. Median VI was 3.7% (interquartile range [IQR] 3.2%-4.2%) in the IUGR group and 10.1% (IQR 8.6%-10.9%) in the control group (p = 0.001). Median FI value was 40.0 (IQR 39.7-42.5) in the IUGR group and 45.1 (IQR 44.1-53.1) in the control group (p = 0.012). Median VFI was 2.2 (IQR 2.1-2.4) in the IUGR group and 4.8 (IQR 4.4-5.3) in the control. The 3DPD indices may be useful for examining changes in circulation in IUGR pregnancies to characterize the underlying pathology. Orv Hetil. 2017; 158(26): 1008-1013.

  17. Value Of Three Dimensional Power Doppler Ultrasound In Prediction Of Endometrial Carcinoma In Patients With Postmenopausal Bleeding

    International Nuclear Information System (INIS)

    Abou-Gabal, A.; Akl, Sh.A.; Hussain, Sh.H.; Allam, H.A.

    2013-01-01

    Objective: to determine whether endometrial volume or power Doppler indices as measured by 3D ultrasound imaging can discriminate between benign and malignant endometrium in women with postmenopausal bleeding and endometrial thickness > 5 mm. Study design: Eighty-four patients with postmenopausal bleeding and endometrial thickness > 5 mm underwent 3D power Doppler ultrasound examination of the corpus uteri. The endometrial volume was calculated, along with the vascularisation index (VI), flow index and vascularisation flow index (VFI) in the endometrium. The gold standard was the histological diagnosis of the endometrium. Results: There were 56 benign and 28 malignant endometrial. Endometrial thickness and volume were significantly larger in malignant than in benign endometrial, and flow indices in the endometrium were Significantly higher. The area under the ROC curve (AUC) of endometrial thickness was 0.83, that of endometrial volume 0.73, and that of the best power Doppler variable FI 0.93. The best logistic regression model for predicting malignancy contained the variables endometrial thickness and FI. Its AUC was 0.93. Conclusion: the diagnostic performance of endometrial volume measured by 3d imaging with regard to discriminating between benign and malignant endometrium was not superior to that of endometrial thickness measured by 2D ultrasound examination, but 3D power Doppler flow indices are good diagnostic tool in predicting endometrial carcinoma

  18. Assessment of placental volume and vascularization at 11-14 weeks of gestation in a Taiwanese population using three-dimensional power Doppler ultrasound.

    Science.gov (United States)

    Wang, Hsing-I; Yang, Ming-Jie; Wang, Peng-Hui; Wu, Yi-Cheng; Chen, Chih-Yao

    2014-12-01

    The placental volume and vascular indices are crucial in helping doctors to evaluate early fetal growth and development. Inadequate placental volume or vascularity might indicate poor fetal growth or gestational complications. This study aimed to evaluate the placental volume and vascular indices during the period of 11-14 weeks of gestation in a Taiwanese population. From June 2006 to September 2009, three-dimensional power Doppler ultrasound was performed in 222 normal pregnancies from 11-14 weeks of gestation. Power Doppler ultrasound was applied to the placenta and the placental volume was obtained by a rotational technique (VOCAL). The three-dimensional power histogram was used to assess the placental vascular indices, including the mean gray value, the vascularization index, the flow index, and the vascularization flow index. The placental vascular indices were then plotted against gestational age (GA) and placental volume. Our results showed that the linear regression equation for placental volume using gestational week as the independent variable was placental volume = 18.852 × GA - 180.89 (r = 0.481, p power Doppler ultrasonography showed a constant distribution throughout gestation. Copyright © 2014. Published by Elsevier Taiwan.

  19. Two- and three-dimensional transvaginal ultrasound with power Doppler angiography and gel infusion sonography for diagnosis of endometrial malignancy.

    Science.gov (United States)

    Dueholm, M; Christensen, J W; Rydbjerg, S; Hansen, E S; Ørtoft, G

    2015-06-01

    To evaluate the diagnostic efficiency of two-dimensional (2D) and three-dimensional (3D) transvaginal ultrasonography, power Doppler angiography (PDA) and gel infusion sonography (GIS) at offline analysis for recognition of malignant endometrium compared with real-time evaluation during scanning, and to determine optimal image parameters at 3D analysis. One hundred and sixty-nine consecutive women with postmenopausal bleeding and endometrial thickness ≥ 5 mm underwent systematic evaluation of endometrial pattern on 2D imaging, and 2D videoclips and 3D volumes were later analyzed offline. Histopathological findings at hysteroscopy or hysterectomy were used as the reference standard. The efficiency of the different techniques for diagnosis of malignancy was calculated and compared. 3D image parameters, endometrial volume and 3D vascular indices were assessed. Optimal 3D image parameters were transformed by logistic regression into a risk of endometrial cancer (REC) score, including scores for body mass index, endometrial thickness and endometrial morphology at gray-scale and PDA and GIS. Offline 2D and 3D analysis were equivalent, but had lower diagnostic performance compared with real-time evaluation during scanning. Their diagnostic performance was not markedly improved by the addition of PDA or GIS, but their efficiency was comparable with that of real-time 2D-GIS in offline examinations of good image quality. On logistic regression, the 3D parameters from the REC-score system had the highest diagnostic efficiency. The area under the curve of the REC-score system at 3D-GIS (0.89) was not improved by inclusion of vascular indices or endometrial volume calculations. Real-time evaluation during scanning is most efficient, but offline 2D and 3D analysis is useful for prediction of endometrial cancer when good image quality can be obtained. The diagnostic efficiency at 3D analysis may be improved by use of REC-scoring systems, without the need for calculation of

  20. Three-dimensional power doppler ultrasound is useful to monitor the response to treatment in a patient with primary papillary serous carcinoma of the peritoneum.

    Science.gov (United States)

    Su, Jen-Min; Huang, Yu-Fang; Chen, Helen H W; Cheng, Ya-Min; Chou, Cheng-Yang

    2006-05-01

    To date, this is the first report to monitor changes of intratumor vascularization and the response to radiation and Cyberknife therapy in a patient with recurrent primary papillary serous carcinoma of the peritoneum by three dimensional (3D) power Doppler ultrasonography (PDUS). Transvaginal 3D PDUS detected a recurrent presacral tumor with abundant intratumor vascularity. Serial examinations of the tumor volume and serum CA-125 level were studied before, during, and 6 mo after therapy. Meanwhile, the intratumor blood flow was measured and expressed as vascularity indices. All of the tumor volume, intratumor vascularity indices and serum CA-125 level decreased progressively following therapy. A remaining lesion with nearly absent intratumor power Doppler signals suggested a scarring lesion posttreatment. Indeed, CT-guided tissue biopsy confirmed fibrotic change. 3D PDUS is useful to monitor the response to treatments and to differentiate residual tumors from lesions of scarring change posttreatment. It provides more accurate posttreatment information than pelvic computed tomography.

  1. Ultrasound-mediated microbubble enhancement of radiation therapy studied using three-dimensional high-frequency power Doppler ultrasound.

    Science.gov (United States)

    Kwok, Sheldon J J; El Kaffas, Ahmed; Lai, Priscilla; Al Mahrouki, Azza; Lee, Justin; Iradji, Sara; Tran, William Tyler; Giles, Anoja; Czarnota, Gregory J

    2013-11-01

    Tumor responses to high-dose (>8 Gy) radiation therapy are tightly connected to endothelial cell death. In the study described here, we investigated whether ultrasound-activated microbubbles can locally enhance tumor response to radiation treatments of 2 and 8 Gy by mechanically perturbing the endothelial lining of tumors. We evaluated vascular changes resulting from combined microbubble and radiation treatments using high-frequency 3-D power Doppler ultrasound in a breast cancer xenograft model. We compared treatment effects and monitored vasculature damage 3 hours, 24 hours and 7 days after treatment delivery. Mice treated with 2 Gy radiation and ultrasound-activated microbubbles exhibited a decrease in vascular index to 48 ± 10% at 24 hours, whereas vascular indices of mice treated with 2 Gy radiation alone or microbubbles alone were relatively unchanged at 95 ± 14% and 78 ± 14%, respectively. These results suggest that ultrasound-activated microbubbles enhance the effects of 2 Gy radiation through a synergistic mechanism, resulting in alterations of tumor blood flow. This novel therapy may potentiate lower radiation doses to preferentially target endothelial cells, thus reducing effects on neighboring normal tissue and increasing the efficacy of cancer treatments. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.

  2. Three-dimensional laser cooling at the Doppler limit

    Science.gov (United States)

    Chang, R.; Hoendervanger, A. L.; Bouton, Q.; Fang, Y.; Klafka, T.; Audo, K.; Aspect, A.; Westbrook, C. I.; Clément, D.

    2014-12-01

    Many predictions of Doppler-cooling theory of two-level atoms have never been verified in a three-dimensional geometry, including the celebrated minimum achievable temperature ℏ Γ /2 kB , where Γ is the transition linewidth. Here we show that, despite their degenerate level structure, we can use helium-4 atoms to achieve a situation in which these predictions can be verified. We make measurements of atomic temperatures, magneto-optical trap sizes, and the sensitivity of optical molasses to a power imbalance in the laser beams, finding excellent agreement with Doppler theory. We show that the special properties of helium, particularly its small mass and narrow transition linewidth, prevent effective sub-Doppler cooling with red-detuned optical molasses. This discussion can be generalized to identify when a given species is likely to be subject to the same limitation.

  3. [Two- and three-dimensional power Doppler ultrasound in the follow-up of placenta accreta treated conservatively].

    Science.gov (United States)

    Roulot, A; Barranger, E; Morel, O; Soyer, P; Héquet, D

    2015-02-01

    To determinate the potential of 2D and 3D-ultrasound in the follow-up of patients with placenta accreta treated conservatively. Seven patients with placenta accreta treated conservatively during June 2007 and September 2009 were included. The follow-up consisted in clinical examination and 2D/3D-ultrasound once a month. Criteria studied included clinical outcome, echogenicity at 2D-ultrasound, vascularisation at colour Doppler, Mean Grey at 3D-ultrasound and vascularisation, flow and perfusion index. Seven women with invasive placenta (3 placentas accreta and 2 percreta) were studied. The mean follow-up was 228 days [75-369]. Mean delay for complete elimination of residual placenta was 280 days [120-365]. The two main results were: presence of an increased anechogenicpart in residual placenta before complete resorption for all patients; a systematic and concomitant stop of genital haemorrhage and vascularisation at colour Doppler. High degrees of variability in parameters measured at 3D-ultrasound were observed between patients so that correlations with clinical outcome were found. Long and regular follow-up is essential after conservative management but the role of 3D-ultrasound compared to 2D-ultrasound was not demonstrated in this study. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  4. Three-dimensional ultrasonography and power Doppler for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding.

    Science.gov (United States)

    El-Sharkawy, Mohamed; El-Mazny, Akmal; Ramadan, Wafaa; Hatem, Dina; Abdel-Hafiz, Aly; Hammam, Mohamed; Nada, Adel

    2016-03-16

    Ultrasonography has been extensively used in women suspected of having a gynecological malignancy. The aim of this study is to evaluate the efficacy of 3D ultrasonography and power Doppler for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding. This cross-sectional study included 78 premenopausal women with abnormal uterine bleeding scheduled for hysteroscopy and endometrial curettage. The endometrial thickness (ET), uterine artery pulsatility index (PI) and resistance index (RI), and endometrial volume (EV) and 3D power Doppler vascularization index (VI), flow index (FI), and vascularization flow index (VFI) were measured and compared with hysteroscopic and histopathologic findings. The ET (P benign and malignant endometrium was the VI with an area under the ROC curve of 0.88 at a cutoff value of 0.81%. 3D ultrasonography and power Doppler, especially endometrial VI, may be useful for discrimination between benign and malignant endometrium in premenopausal women with abnormal uterine bleeding.

  5. Three-dimensional power Doppler ultrasound in the early assessment of response to concurrent chemo-radiotherapy for advanced cervical cancer.

    Science.gov (United States)

    Xu, Yan; Zhu, Lijing; Ru, Tong; Wang, Huanhuan; He, Jian; Zhou, Zhengyang; Yang, Xiaofeng

    2017-09-01

    Background Three-dimensional power Doppler ultrasound (3D-PDU) imaging has been widely applied to the differentiation of benign and malignant cervical lesions; however, its potential value for predicting response to chemo-radiotherapy has not been fully explored. Purpose To investigate the feasibility of 3D-PDU imaging in predicting treatment response in patients receiving concurrent chemo-radiotherapy (CCRT) for advanced cervical cancer. Material and Methods Fifty-two patients with advanced cervical cancer who received CCRT underwent 3D-PDU examinations at four timepoints: pre-therapy (baseline), 1 week and 2 weeks during, as well as immediately post CCRT. Final tumor response was determined by change in tumor size using magnetic resonance imaging (MRI). Cervical tumor volumes and vascular indices were calculated and compared with the clinical outcome. Results Of the 52 patients, 32 patients who completed all four examinations were included in the analyses: 21 were classified as complete response (CR) and 11 as partial response (PR). During the treatment, the CR group showed that 3D vascular indices (VI and VFI) significantly increased at 1 week ( P = 0.028, P = 0.017, respectively) then decreased at 2 weeks and obviously decreased at therapy completion (both P  0.05). Conclusion Prospective longitudinal 3D-PDU imaging may have potentials in monitoring early therapeutic response to CCRT in patients with cervical cancer.

  6. Correlation between three-dimensional power Doppler and morphometric measurement of endometrial vascularity at the time of embryo implantation in women with unexplained recurrent miscarriage.

    Science.gov (United States)

    Chen, Xiaoyan; Saravelos, Sotirios H; Liu, Yingyu; Huang, Jin; Wang, Chi Chiu; Li, Tin Chiu

    2017-06-01

    Power Doppler in combination with three-dimensional (3D-PD) ultrasonography has been used as a noninvasive tool to evaluate the vascularity. However, it is unclear whether 3D-PD can accurately reflect endometrial vascularization and replace the invasive endometrial biopsy. This study aims to investigate the correlation between 3D-PD and micro vessel morphometric measurement of endometrial vascularity. Twenty-five women with unexplained recurrent miscarriage were recruited for 3D-PD and endometrial biopsy on precisely day LH + 7. Immunohistochemistry using vWF was employed to identify micro vessels in endometrial biopsy specimens followed by the use of morphometric technique to measure the mean vessel diameter and volume fractions. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) assessed by 3D-PD were calculated for both the endometrial and sub-endometrial regions. There were no significant correlations between any of the ultrasonographic measurements (endometrial thickness, endometrial volume, endometrial VI/FI/VFI, sub-endometrial volume, sub-endometrial VI/FI/VFI) and morphometric features (number of micro vessel, mean diameter of micro vessel and volume fraction measurement of vessel). This study indicates that endometrial vascularity assessed by 3D-PD could not be used to reflect changes in micro vessels of the endometrium at the time of embryo implantation in women with unexplained recurrent miscarriage.

  7. Is there a role for 3 dimensional power Doppler placental ultrasound and computerised assessment of calcification in post-term pregnancies?

    International Nuclear Information System (INIS)

    Moran, M.; Zombori, G.; Ryan, J.; Downey, P.; McAuliffe, F.M.

    2016-01-01

    Purpose: To assess if three dimensional power Doppler (3DPD) placental ultrasound, evaluating volume, vascularisation, and blood flow in post-term pregnancies differs from normal pre-term third trimester pregnancies and to examine whether computer analysis identifies the continual increase in calcification in post-term pregnancies. Materials and methods: A prospective cohort study of 50 women with post-term pregnancies (40 + 0 to 41 + 6 weeks) and 58 controls (36–40 weeks). 3DPD ultrasound was used to evaluate placental volume, vascularisation index (VI), flow index (FI) and vascularisation-flow index (VFI). Calcification percentage was calculated, by computer analysis. Results were compared with previously determined normal values and correlated with uterine, middle cerebral and umbilical artery Doppler values and placental histology. Results: Placental volume, VI, FI and VFI are not influenced by GA beyond 40 weeks gestation and are similar between post-term and normal pregnancies (36–40 weeks). Placental volume decreased as the mean uterine artery pulsatility index (UtA PI) increased; p = 0.047. FI was reduced where chorangiosis was found at histology (p = 0.033). Computer analysis of placental calcification identified the increased calcification expected after 40 weeks, and showed that calcification continues to increase between 40 and 42 weeks (p = 0.029). Conclusion: Although the sample size limits the generalisability of the findings, we found that calcification of the placenta continues to increase between 40 and 42 weeks gestation, that there is an association between an increasing UtA PI and a decreasing placental volume and that FI measurement may be useful in the identification of chorangiosis in post-term pregnancies. - Highlights: • Placental volume does not increase when pregnancy advances beyond 40 weeks gestation. • Placental volume decreases in post-term pregnancies as the mean uterine artery pulsatility index increases. • Flow

  8. Comparison of placental three-dimensional power Doppler indices and volume in the first and second trimesters of pregnancy complicated by gestational diabetes mellitus.

    Science.gov (United States)

    Wong, Chian-Huey; Chen, Chie-Pein; Sun, Fang-Ju; Chen, Chen-Yu

    2018-05-01

    To compare the changes of placental three-dimensional power Doppler indices and volume in the first and second trimesters of pregnancy with gestational diabetes mellitus (GDM). This was a prospective case-control study of singleton pregnancies with risk factors for GDM. Data on placental vascular indices including vascularization index (VI), flow index (FI), and vascularization flow index (VFI), as well as placental volume were obtained and analyzed during the first and second trimesters between pregnant women with and without GDM. Of the 155 pregnant women enrolled, 31 developed GDM and 124 did not. VI and VFI were significantly lower in the GDM group during the first and second trimesters (VI: p = 0.023, and VFI: p = 0.014 in the first trimester; VI: p = 0.049, and VFI: p = 0.031 in the second trimester). However, the placental volume was similar in both groups during the first trimester, while it was significantly increased in the GDM group during the second trimester (p = 0.022). There were no significant differences in FI and uterine artery pulsatility index between the two groups. After adjustments in multivariate logistic regression analysis, significant differences were observed in the first trimester VFI (adjusted odds ratio (OR) 0.76, 95% confidence interval (CI) 0.61-0.93), second trimester VFI (adjusted or 0.83, 95% CI 0.71-0.96), and second trimester placental volume (adjusted or 1.03, 95% CI 1.01-1.05). Placental vascular indices can provide an insight into placental vascularization in GDM during early pregnancy. VFI rather than placental volume may be a sensitive sonographic marker in the first trimester of GDM placentas.

  9. Comparative Analysis of Logistic Regression, Support Vector Machine and Artificial Neural Network for the Differential Diagnosis of Benign and Malignant Solid Breast Tumors by the Use of Three-Dimensional Power Doppler Imaging

    International Nuclear Information System (INIS)

    Chen, Shou Tung; Hsiao, Yi Hsuan; Kuo, Shou Jen; Tseng, Hsin Shun; Wu, Hwa Koon; Chen, Dar Ren; Huang, Yu Len

    2009-01-01

    Logistic regression analysis (LRA), Support Vector Machine (SVM) and a neural network (NN) are commonly used statistical models in computeraided diagnostic (CAD) systems for breast ultrasonography (US). The aim of this study was to clarify the diagnostic ability of the use of these statistical models for future applications of CAD systems, such as three-dimensional (3D) power Doppler imaging, vascularity evaluation and the differentiation of a solid mass. A database that contained 3D power Doppler imaging pairs of non-harmonic and tissue harmonic images for 97 benign and 86 malignant solid tumors was utilized. The virtual organ computer-aided analysis-imaging program was used to analyze the stored volumes of the 183 solid breast tumors. LRA, an SVM and NN were employed in comparative analyses for the characterization of benign and malignant solid breast masses from the database. The values of area under receiver operating characteristic (ROC) curve, referred to as Az values for the use of non-harmonic 3D power Doppler US with LRA, SVM and NN were 0.9341, 0.9185 and 0.9086, respectively. The Az values for the use of harmonic 3D power Doppler US with LRA, SVM and NN were 0.9286, 0.8979 and 0.9009, respectively. The Az values of six ROC curves for the use of LRA, SVM and NN for non-harmonic or harmonic 3D power Doppler imaging were similar. The diagnostic performances of these three models (LRA, SVM and NN) are not different as demonstrated by ROC curve analysis. Depending on user emphasis for the use of ROC curve findings, the use of LRA appears to provide better sensitivity as compared to the other statistical models

  10. [Diagnostic value of power Doppler ultrasonography for Sirenomelia Seguence in prenatal].

    Science.gov (United States)

    Yan, Xia-yu; Yang, Tai-zhu; Luo, Hong; Tian, Yu; Yang, Fan

    2011-11-01

    To study and discuss the diagnostic value and ultrasonographic characteristics of power doppler ultrasound in the prenatal diagnosis of Sirenomelia Seguence. The abdominal aorta in two fetuses with sirenomelia seguence fetuses and in ten with nomal was reviewed and compared with two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound in prenatal. The abdominal aorta were showed to divid into renal arteries in the kidney level while two common iliac arteries in the pelvis in nomal fetuses with two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound; compared with the nomal, the abdominal aorta and whose branches in sirenomelia seguence were demonstrated as follows: 1) a large and deformed vascular coming from the high abdominal aorta, which was found to act as a umbilical artery by careful examination; 2) no bifurcation of renal arteries identified; 3) no bifurcation of two common iliac arteries identified; 4) the abdominal aorta changing into a narrow vascular after one deformed vascular separating from. Sirenomelia seguence fetuses has a characteristic change in two-dimensional power doppler ultrasound and three-dimensional power doppler ultrasound, which is helpful to improve the prenatal diagnosis of sirenomelia seguence.

  11. 3D power Doppler ultrasound in early diagnosis of preeclampsia.

    Science.gov (United States)

    Neto, R Moreira; Ramos, J G L

    2016-01-01

    Preeclampsia is a known cause of maternal, fetal and neonatal morbidity and mortality. Thus, evaluation of the predicting value of comparing 3D power Doppler indices (3DPD) of uteroplacental circulation (UPC) in the first and second trimester in patients who developed preeclampsia (PE) and those who did not and testing the hypothesis that the parameters of vascularization and placenta flow intensity, as determined by three-dimensional ultrasound (3D), are different in normal pregnancies compared with preeclampsia, could be a suitable screening method. A prospective observational study using 3D power Doppler were performed to evaluate the placental perfusion in 96 pregnant women who came to do the ultrasound routine between 11 and 14 weeks. The placental vascular index (VI), flow index (FI), blood vessels and blood flow index (VFI) by three-dimensional Doppler histogram were calculated. All patients repeated the exam between 16 and 20 weeks. The outcome was scored as normal or preeclamptic. Placental vascular indices including VI, FI and VFI were significantly lower in preeclamptic placentas compared with controls in the study performed in the second trimester (ppower Doppler assessment of placental vascular indices in the second trimester has the potential to detect women at risk for subsequent development of PE. Copyright © 2015 International Society for the Study of Hypertension in Pregnancy. Published by Elsevier B.V. All rights reserved.

  12. Power doppler 'blanching' after the application of transducer pressure

    International Nuclear Information System (INIS)

    Joshua, F.; Edmonds, J.; Lassere, M.; De Carle, R.; Rayment, M.; Bryant, C.; Shnier, R.

    2005-01-01

    The aim of this study was to determine if transducer pressure modifies power Doppler assessments of rheumatoid arthritis synovium at the metacarpophalangeal joints and metatarsophalangeal joints. Five rheumatoid arthritis patients of varying degrees of 'disease activity' and damage were assessed with power Doppler ultrasound scanning of the dominant hand second to fifth metacarpophalangeal joints. Two rheumatoid arthritis patients had their dominant foot first to fifth metatarsophalangeal joints assessed with power Doppler ultrasound. Ultrasonography was performed with a high frequency transducer (14 MHz) with a colour mode frequency of 10 Mhz, and a standard colour box and gain. In the joint that showed the highest power Doppler signal, an image was made. A further image was taken after transducer pressure was applied. In all patients, there was increased flow to at least one joint. After pressure was applied, power Doppler signal intensity markedly reduced in all images and in some there was no recordable power Doppler signal. Increased transducer pressure can result in a marked reduction or obliteration in power Doppler signal. This power Doppler 'blanching' shows the need for further studies to evaluate sources of error and standardization before power Doppler ultrasound becomes a routine measure of 'disease activity' in rheumatoid arthritis. Copyright (2005) Blackwell Science Pty Ltd

  13. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  14. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  15. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  16. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  17. Temporal enhancement of two-dimensional color doppler echocardiography

    Science.gov (United States)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  18. Low-frequency high-definition power Doppler in visualizing and defining fetal pulmonary venous connections.

    Science.gov (United States)

    Liu, Lin; He, Yihua; Li, Zhian; Gu, Xiaoyan; Zhang, Ye; Zhang, Lianzhong

    2014-07-01

    The use of low-frequency high-definition power Doppler in assessing and defining pulmonary venous connections was investigated. Study A included 260 fetuses at gestational ages ranging from 18 to 36 weeks. Pulmonary veins were assessed by performing two-dimensional B-mode imaging, color Doppler flow imaging (CDFI), and low-frequency high-definition power Doppler. A score of 1 was assigned if one pulmonary vein was visualized, 2 if two pulmonary veins were visualized, 3 if three pulmonary veins were visualized, and 4 if four pulmonary veins were visualized. The detection rate between Exam-1 and Exam-2 (intra-observer variability) and between Exam-1 and Exam-3 (inter-observer variability) was compared. In study B, five cases with abnormal pulmonary venous connection were diagnosed and compared to their anatomical examination. In study A, there was a significant difference between CDFI and low-frequency high-definition power Doppler for the four pulmonary veins observed (P low-frequency high-definition power Doppler was higher than that when employing two-dimensional B-mode imaging or CDFI. There was no significant difference between the intra- and inter-observer variabilities using low-frequency high-definition power Doppler display of pulmonary veins (P > 0.05). The coefficient correlation between Exam-1 and Exam-2 was 0.844, and the coefficient correlation between Exam-1 and Exam-3 was 0.821. In study B, one case of total anomalous pulmonary venous return and four cases of partial anomalous pulmonary venous return were diagnosed by low-frequency high-definition power Doppler and confirmed by autopsy. The assessment of pulmonary venous connections by low-frequency high-definition power Doppler is advantageous. Pulmonary venous anatomy can and should be monitored during fetal heart examination.

  19. Evaluating the intra- and interobserver reliability of three-dimensional ultrasound and power Doppler angiography (3D-PDA) for assessment of placental volume and vascularity in the second trimester of pregnancy.

    Science.gov (United States)

    Jones, Nia W; Raine-Fenning, Nick J; Mousa, Hatem A; Bradley, Eileen; Bugg, George J

    2011-03-01

    Three-dimensional (3-D) power Doppler angiography (3-D-PDA) allows visualisation of Doppler signals within the placenta and their quantification is possible by the generation of vascular indices by the 4-D View software programme. This study aimed to investigate intra- and interobserver reproducibility of 3-D-PDA analysis of stored datasets at varying gestations with the ultimate goal being to develop a tool for predicting placental dysfunction. Women with an uncomplicated, viable singleton pregnancy were scanned at 12, 16 or 20 weeks gestational age groups. 3-D-PDA datasets acquired of the whole placenta were analysed using the VOCAL software processing tool. Each volume was analysed by three observers twice in the A plane. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICCs) and Bland Altman plots. At each gestational age group, 20 low risk women were scanned resulting in 60 datasets in total. The ICC demonstrated a high level of measurement reliability at each gestation with intraobserver values >0.90 and interobserver values of >0.6 for the vascular indices. Bland Altman plots also showed high levels of agreement. Systematic bias was seen at 20 weeks in the vascular indices obtained by different observers. This study demonstrates that 3-D-PDA data can be measured reliably by different observers from stored datasets up to 18 weeks gestation. Measurements become less reliable as gestation advances with bias between observers evident at 20 weeks. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  20. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  1. High-Frame-Rate Power Doppler Ultrasound Is More Sensitive than Conventional Power Doppler in Detecting Rheumatic Vascularisation

    NARCIS (Netherlands)

    M. van der Ven (Myrthe); J.J. Luime (Jolanda); van der Velden, L.L. (Levinia L.); J.G. Bosch (Hans); J.M.W. Hazes (Mieke); H.J. Vos (Rik)

    2016-01-01

    textabstractEarly recognition of joint inflammation will increase treatment efficacy in rheumatoid arthritis (RA). Yet, conventional power Doppler (PD) ultrasound might not be sufficiently sensitive to detect minor inflammation. We investigated the sensitivity of high-frame rate Doppler, combined

  2. Muscle blood volume assessment during exercise with Power Doppler Ultrasound

    NARCIS (Netherlands)

    Heres, H.M.; Tchang, B.C.Y.; Schoots, T.; Rutten, M.C.M.; van de Vosse, F.N.; Lopata, R.G.P.

    2016-01-01

    Assessment of perfusion adaptation in muscle during exercise can provide diagnostic information on cardiac and endothelial diseases. Power Doppler Ultrasound (PDUS) is known for its feasibility in the non-invasive measurement of moving blood volume (MBV), a perfusion related parameter. In this

  3. Renal Power Doppler Ultrasonographic Evaluation of Children With Acute Pyelonephritis

    Directory of Open Access Journals (Sweden)

    Ali Pahlusi

    2011-10-01

    Full Text Available Urinary tract infections are common in children. The available gold standard method for diagnosis, Tc-99m dimercaptosuccinic acid scan is expensive and exposes patients to considerable amount of radiation. This study was performed to compare and assess the efficacy of Power Doppler Ultrasound versus Tc-99m DMSA scan for diagnosis of acute pyelonephritis. A quasi experimental study was conducted on 34 children with mean age of 2.82.7 years who were hospitalized with their first episode of febrile urinary tract infection. All children were evaluated in the first 3 days of admission by Doppler Ultrasound and Tc-99m DMSA scan. Patients with congenital structural anomalies were excluded. Each kidney was divided into three zones. The comparison between efficacy of Doppler Ultrasound and DMSA scan was carried out based on number of patients and on classified renal units. Based on the number of patients enrolled; the sensitivity, specificity, positive and negative predictive values and accuracy of Doppler Ultrasound were 89%, 53%, 70%, 80% and 74%, respectively but based on the renal units, it was 66%, 81%, 46%, 91% and 79% , respectively. Although Doppler Ultrasound has the potential for identifying acute pyelonephritis in children, but it is still soon to replace DMSA scan.

  4. The clinical study of 2D and power doppler ultrasound in esophagus varix

    International Nuclear Information System (INIS)

    Li Qiang; Zhou Liang; Zhang Yucheng; Yang Minghua; Ruan Fenglian; Lu Haixia; Li Yue

    2008-01-01

    Objective: To study the application of 2D and Power Doppler Ultrasound in diagnosing the abdominal esophageal varicose veins. Methods: 65 patients under suspicion with chronic hepatitis and cirrhosis for esophageal varicose at esophagus in abdomen section were examined by 2D and Power Doppler Ultrasound.Among them, 35 patients suffered from esophageal varicose veins proved by gastroscopy and the rest did not. Results: On the power doppler imaging map, colored blood stream signals were showed in varicose veins while without signals in non-varicose veins.The diagnostic sensitivity and specificity were 91.4% and 100% respectively. On the two-dimensional image chart, non-echoes were represented in varicose veins. The anteroposterior diameter, right-left diameter, as well as the thickness of esophagus wall were larger in patients with varicose veins than those in non varicose veins cases (P<0.01). Conclusion: 2D combined with Power Doppler Ultrasound was of non-invasive, safe, sensitive and high specificity, which is a valuable and practical tool in diagnosing the esophageal varicose veins. (authors)

  5. The Use of 3D Power Doppler Ultrasound in the Quantification of Blood Vessels in Uterine Fibroids: Feasibility and Reproducibility

    NARCIS (Netherlands)

    Nieuwenhuis, L.L.; Betjes, H.E.; Hehenkamp, W.J.K.; Heymans, M.W.; Brölmann, H.A.M.; Huirne, J.A.F.

    2015-01-01

    Background: To evaluate the interobserver agreement and discriminating value of three-dimensional power Doppler ultrasound (3D PDUS) in patients with fibroids. Methods: An observational prospective cohort study in 19 patients with fibroids. 3D PDUS was performed by one examiner and evaluated by

  6. Three-dimensional colour Doppler of ductus venosus agenesis in ...

    African Journals Online (AJOL)

    was bilateral pleural effusion with generalised subcutaneous oedema suggestive of hydrops fetalis (Fig. 1B). Colour Doppler sonography revealed the umbilical vein draining into the portal sinus with non-visualisation of the DV, which would connect the portal sinus with the inferior vena cava (IVC) (Figs 1C and 1D). Hence ...

  7. Differential Laser Doppler based Non-Contact Sensor for Dimensional Inspection with Error Propagation Evaluation

    Directory of Open Access Journals (Sweden)

    Ketsaya Vacharanukul

    2006-06-01

    Full Text Available To achieve dynamic error compensation in CNC machine tools, a non-contactlaser probe capable of dimensional measurement of a workpiece while it is being machinedhas been developed and presented in this paper. The measurements are automatically fedback to the machine controller for intelligent error compensations. Based on a well resolvedlaser Doppler technique and real time data acquisition, the probe delivers a very promisingdimensional accuracy at few microns over a range of 100 mm. The developed opticalmeasuring apparatus employs a differential laser Doppler arrangement allowing acquisitionof information from the workpiece surface. In addition, the measurements are traceable tostandards of frequency allowing higher precision.

  8. Sound Power Estimation by Laser Doppler Vibration Measurement Techniques

    Directory of Open Access Journals (Sweden)

    G.M. Revel

    1998-01-01

    Full Text Available The aim of this paper is to propose simple and quick methods for the determination of the sound power emitted by a vibrating surface, by using non-contact vibration measurement techniques. In order to calculate the acoustic power by vibration data processing, two different approaches are presented. The first is based on the method proposed in the Standard ISO/TR 7849, while the second is based on the superposition theorem. A laser-Doppler scanning vibrometer has been employed for vibration measurements. Laser techniques open up new possibilities in this field because of their high spatial resolution and their non-intrusivity. The technique has been applied here to estimate the acoustic power emitted by a loudspeaker diaphragm. Results have been compared with those from a commercial Boundary Element Method (BEM software and experimentally validated by acoustic intensity measurements. Predicted and experimental results seem to be in agreement (differences lower than 1 dB thus showing that the proposed techniques can be employed as rapid solutions for many practical and industrial applications. Uncertainty sources are addressed and their effect is discussed.

  9. Characterization of benign and malignant solid breast masses in harmonic 3D power Doppler imaging

    International Nuclear Information System (INIS)

    Hsiao, Y.-H.; Huang, Y.-L.; Kuo, S.-J.; Liang, W.-M.; Chen, S.-T.; Chen, D.-R.

    2009-01-01

    Purpose: The authors assessed the characteristics of benign and malignant solid breast tumors in harmonic three-dimensional (3D) power Doppler imaging and proposed decision models to classify benign and malignant breast tumors. Materials and methods: A total of 86 malignant and 97 benign harmonic 3D power Doppler US images were analyzed. All the harmonic 3D power Doppler images were obtained using a Voluson730 US system (GE, Zipf, Austria) equipped with a RSP 6-12 transducer and tissue harmonic imaging modalities. Imaging analysis was performed using the Virtual Organ Computer-aided Analysis (VOCAL)-imaging program. Histogram indices, the vascularization index (VI), flow index (FI) and vascularization-flow index (VFI), were calculated for the intra-tumor and for shells with an outside thickness of 3 mm surrounding the breast tumors. The receiver operating characteristic (ROC) curves were calculated to estimate the diagnostic performances. Results: The results revealed that the choice of decision model comprised the parameters of patient age, intra-tumor VI, and tumor volume to classify benign and malignant breast tumors. The area under the ROC curve (Az) was 0.910, accuracy was 81.4%, and sensitivity and specificity were 81.4% and 81.4%, respectively. The parameter intra-tumor VI was the choice for all of the histogram indices in differentiating between malignant and benign lesions. Conclusion: The decision model, which was composed of patient age, tumor volume and intra-tumor VI, and a cut-off value for intra-tumor VI at the upper end of patient age and tumor volume, was recommended in clinical application.

  10. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  11. Acute Effects of Lateral Thigh Foam Rolling on Arterial Tissue Perfusion Determined by Spectral Doppler and Power Doppler Ultrasound.

    Science.gov (United States)

    Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U

    2017-04-01

    Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.

  12. Contrast-enhanced power Doppler US in the characterization of renal masses; Power Doppler con mezzo di contrasto nella caratterizzazione delle masse renali

    Energy Technology Data Exchange (ETDEWEB)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E. [Messina Univ., Messina (Italy). Ist. di Scienze Radiologiche

    2000-09-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts. [Italian] Scopo di questo articolo e' quello di riportare i risultati di uno studio prospettico finalizzato ad individuare le potenzialita' del power Doppler con mdc ecografico nella caratterizzazione delle lesioni espansive del rene. Dal 1997 al 30 ottobre 1999 sono state studiate 59 lesioni renali (28 maligne, 31 benigne) in 48 pazienti (eta' media 55 anni, intervallo 10

  13. Value of Quantitative Three-dimensional Doppler Ultrasound in the Differentiation of Benign and Malignant Thyroid Nodules.

    Science.gov (United States)

    Li, Wen-Bo; Zhang, Bo; Jiang, Yu-Xin; Zhu, Qing-Li; Zhang, Qing; Sun, Jian

    2015-06-01

    To investigate the role of quantitative three-dimensional (3D) power Doppler ultrasound in differentiating malignant and benign thyroid nodule. A total of 92 lesions in 86 patients were preoperatively examined using 3D power Doppler ultrasound. The Virtual Organ Computer-aided Analysis(VOCAL)-imaging program was used to analyze the stored volume ultrasound. The differences in the mean gray value (MG), vascularization index (VI), flow index(FI), and vascularization flow index (VFI) were compared between benign and malignant lesions. The MG of the malignant thyroid nodules was significantly lower than that of the benign ones (28.27±7.21 vs. 32.89±8.73,P=0.007). The benign nodules had significantly higher VI,FI,and VFI than the malignant nodules [VI:(40.43±26.55)% vs. (26.87±23.06)%,P=0.011;FI:41.03±7.19 vs. 37.51±7.17,P=0.022;VFI:18.23±14.60 vs. 11.47±12.47, P=0.009]. Also,76.5% (39/51) of the malignant nodules and 92.7% (38/41) of the benign nodules had higher VIs in the shell of the lesion than that of the whole lesion,and 80.4%(41/51) of the malignant nodules and 95.1% (39/41) of the benign nodules had higher FIs in the shell of the lesion than that of the whole lesion. Quantitative 3D power Doppler ultrasound provides a useful tool in distinguishing benign and malignant thyroid nodules. The malignant thyroid nodules have lower echoes than the benign nodules, wherese the benign nodules have larger blood flow than the malignant nodules.

  14. Evaluation of the activity of synovitis in patients with rheumatoid arthritis: Value of power Doppler ultrasonography

    International Nuclear Information System (INIS)

    Ahn, Joong Mo; Lim, Hyo Keun; Kim, Seung Hoon; Kim, Sung Hyun; Koh, Eun Mi; Kim, Jin Seok; Cha, Hoon Suk

    2001-01-01

    To correlate the grades on power Doppler ultrasonography with clinical disease activity indices and acute phase reactant values for assessing the activity of synovitis in patients with rheumatoid arthritis. Twenty patients with rheumatoid arthritis diagnosed on the basis of American College of power Doppler ultrasonography. Two experienced radiologists evaluated, in consensus, the power Doppler signals as follows: grade I=no flow or minimal flow, grade 2=mild flow, grade 3=moderate flow and grade 4= marked flow. The clinical disease activity indices consisted of the counts of tender joints and swollen joints, patient's assessment of pain, patient's global assessment of disease activity, physician's globe assessment of disease activity and patient's assessment of physical function. Acute-phase reactants included CRP and ESR. The grades on power Doppler ultrasonography were correlated with clinical disease activity indices as well as acute-phases reactant values by a use of Spearman rank correlation coefficient. The grades on power Doppler ultrasonography showed a statistically significant correlation with tender joint count (rs=.835; p<.05), swollen joint count (rs=.833; p<.05), physician's global assessment of disease activity (rs=.857; p<.05), CRP (rs=.838; P<.05) and ESR (rs=.838; p<.05). The power Doppler ultrasonography is an useful diagnostic modality for assessing the activity of synovitis in patients with rheumatoid arthritis.

  15. Contrast-enhanced power Doppler US in the characterization of renal masses

    International Nuclear Information System (INIS)

    Ascenti, G.; Zimbaro, G.; Mazziotti, S.; Visalli, C.; Racchiusa, S.; Vinci, S.; Scribano, E.

    2000-01-01

    Purpose of this work is to report the results of a prospective study investigating the potentials of contrast-enhanced power Doppler in the diagnosis of expansive renal lesions. From 1997 to October 30, 1999, it was studied the case of 59 expansive renal lesions (28 malignant, 31 benign) in 48 patients (mean age 55 years, range 10-79) with power Doppler US before and after the administration of an echo-enhancing agent (Levovist, Schering AG, Berlin Germany). Were found 5 patterns of vascular architecture of the lesions, both before and after contrast agent administration, following the classification by Jinzaki e Coll. Power Doppler US showed vascular structures in 34 patients. The administration of Levovist revealed vessels in 12/25 lesions which had none at baseline studies and in 6 cases vascularity was particularly evident. Color signals were enhanced in all the 34 vascularized lesions, which allowed better definition of vascular patterns. The characterization of vascular patterns with baseline power Doppler US helped improve diagnostic accuracy compared to gray-scale US (58% versus 32%) for hyperechoic lesions, complex cysts and pseudomasses. Independent of contrast agent administration, the integration of gray-scale and power Doppler modes increased diagnostic accuracy even further (76% correct diagnoses). In our series, the US contrast agent did not increase the diagnostic accuracy of power Doppler in the differential diagnosis of hyperechoic renal lesions; conversely, Levovist can be advantageous for the characterization of suspected pseudomasses and complex cysts [it

  16. Intratumoral vascularity of experimentally induced VX2 carcinoma : comparison of power doppler sonography and microangiography

    International Nuclear Information System (INIS)

    Park, Kil Sun; Won, Hyung Jin; Seo, Joon Beom; Kim, Tae Kyoung; Han, Joon Koo; Choi, Byung Ihn

    1997-01-01

    To evaluate the usefulness and limitations of power Doppler sonography in determining the tumor vascularity Power Doppler sonography was performed on VX2 carcinomas present in rabbit thighs, and the findings were compared with those of microangiography in an almost identical plane. Tumor vascularity was qualitatively analysed on the basis of tumor vessel distribution and density, and the presence of thick and thin vesels;for a comparison of tumor vascularity as seen on microangiography, tumor blood flow signals shown by power Doppler sonography were graded 3, 2, 1, 0. For quantitative analysis, a comparison was made of the percentage of tumor area occupied by vessels, as shown in each study. Data analysis utilized the Wilcoxon signed-rank test and Spearman correlation test. Mean tumor vascularity scores, as seen on power Doppler sonography and relating to tumor vessel distribution and density, and the presence of thick and thin vessels, were 2.87, 2.73, 2.93 and 2.73, respectively. The means and medians of the percentages of tumor area occupied by vessels were 22.7% and 23.5% and 36.4% and 34.7% on microangiography and power Doppler sonography, respectively. Thus, there was good correlation between these two modes. Power doppler sonography could demonstrate the tumor vascularity on microangiography relatively well but tend to overestimate it

  17. Power doppler ultrasound findings of renal infarct after experimental renal artery occlusion: comparison with spiral CT

    International Nuclear Information System (INIS)

    Jung, Seung Eun; Shinn, Kyung Sub; Kim, Hak Hee; Mun, Seok Hwan; Lee, Young Joon; Lee, Bae Young; Choi, Byung Gil; Lee, Jae Mun; Lee, Hee Jeong

    1999-01-01

    To evaluate the efficacy of power Doppler ultrasonography (PDUS) in depicting renal infarction in rabbits during experimental renal segmental arterial occlusion, and to compare the results with those of CT scanning. In 28 rabbits weighing 2.5 4kg, the segmental renal artery was occluded through the left main renal artery by embolization with Ivalon (Nycomed, Paris, France). Power Doppler ultrasonography and spiral CT scanning were performed before and at 2, 5, 8, 15, and 24 hours, and 3 and 7 days after occlusion of the segmental renal artery. The location of infarcted areas and collaterals, as seen on PDUS and CT scans, was evaluated by two radiologists. In all cases, as seen on power Doppler ultrasonography, infarcted areas-when compared with normal parenchyma, clearly demonstrated wedge-shaped perfusion defects in the kidney. The location of the lesion closely corresponded to the location seen during CT scanning. After renal arterial occlusion, transiently congested capsular arteries, which were named 'capsular sign', were seen in 63% of rabbits in the two and five-hour groups. No significant cortical rim sign was demonstrated on power Doppler ultrasonography, though it was noted on spiral CT at 15 and 24 hours, and 3 and 7 days after renal arterial occlusion. Power Doppler ultrasonography was useful for the diagnosis of renal infarction. Congested capsular artery seen in the early stage of renal infarction might be a characteristic finding of this condition, as seen on power Doppler ultrasonography

  18. Measurement of two-dimensional Doppler wind fields using a field widened Michelson interferometer.

    Science.gov (United States)

    Langille, Jeffery A; Ward, William E; Scott, Alan; Arsenault, Dennis L

    2013-03-10

    An implementation of the field widened Michelson concept has been applied to obtain high resolution two-dimensional (2D) images of low velocity (interferometer scanning mirror position is controlled to subangstrom precision with subnanometer repeatability using the multi-application low-voltage piezoelectric instrument control electronics developed by COM DEV Ltd.; it is the first implementation of this system as a phase stepping Michelson. In this paper the calibration and characterization of the Doppler imaging system is described and the planned implementation of this new technique for imaging 2D wind and irradiance fields using the earth's airglow is introduced. Observations of Doppler winds produced by a rotating wheel are reported and shown to be of sufficient precision for buoyancy wave observations in airglow in the mesopause region of the terrestrial atmosphere.

  19. Three-Dimensional Wind Profiling of Offshore Wind Energy Areas With Airborne Doppler Lidar

    Science.gov (United States)

    Koch, Grady J.; Beyon, Jeffrey Y.; Cowen, Larry J.; Kavaya, Michael J.; Grant, Michael S.

    2014-01-01

    A technique has been developed for imaging the wind field over offshore areas being considered for wind farming. This is accomplished with an eye-safe 2-micrometer wavelength coherent Doppler lidar installed in an aircraft. By raster scanning the aircraft over the wind energy area (WEA), a three-dimensional map of the wind vector can be made. This technique was evaluated in 11 flights over the Virginia and Maryland offshore WEAs. Heights above the ocean surface planned for wind turbines are shown to be within the marine boundary layer, and the wind vector is seen to show variation across the geographical area of interest at turbine heights.

  20. Two-dimensional grayscale ultrasound and spectral Doppler waveform evaluation of dogs with chronic enteropathies.

    Science.gov (United States)

    Gaschen, Lorrie; Kircher, Patrick

    2007-08-01

    Sonography is an important diagnostic tool to examine the gastrointestinal tract of dogs with chronic diarrhea. Two-dimensional grayscale ultrasound parameters to assess for various enteropathies primarily focus on wall thickness and layering. Mild, generalized thickening of the intestinal wall with maintenance of the wall layering is common in inflammatory bowel disease. Quantitative and semi-quantitative spectral Doppler arterial waveform analysis can be utilized for various enteropathies, including inflammatory bowel disease and food allergies. Dogs with inflammatory bowel disease have inadequate hemodynamic responses during digestion of food. Dogs with food allergies have prolonged vasodilation and lower resistive and pulsatility indices after eating allergen-inducing foods.

  1. Power spectral density of velocity fluctuations estimated from phase Doppler data

    OpenAIRE

    Jicha Miroslav; Lizal Frantisek; Jedelsky Jan

    2012-01-01

    Laser Doppler Anemometry (LDA) and its modifications such as PhaseDoppler Particle Anemometry (P/DPA) is point-wise method for optical nonintrusive measurement of particle velocity with high data rate. Conversion of the LDA velocity data from temporal to frequency domain – calculation of power spectral density (PSD) of velocity fluctuations, is a non trivial task due to nonequidistant data sampling in time. We briefly discuss possibilities for the PSD estimation and specify limitations caused...

  2. Power and color Doppler ultrasound settings for inflammatory flow: impact on scoring of disease activity in patients with rheumatoid arthritis.

    Science.gov (United States)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin; Ellegaard, Karen; D'Agostino, Maria Antonietta; Iagnocco, Annamaria; Naredo, Esperanza; Balint, Peter; Wakefield, Richard J; Torp-Pedersen, Arendse; Terslev, Lene

    2015-02-01

    To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. Six different types of ultrasound machines were used. On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. Power Doppler was more sensitive on half of the machines, whereas color Doppler was more sensitive on the other half, using both factory settings and study settings. There was an average increase in Doppler sensitivity, despite modality, of 78% when study settings were applied. Over the 6 machines, 2 Doppler modalities, and 2 settings, the grades for each of 7 of the patients varied between 0 and 3, while the grades for each of the other 4 patients varied between 0 and 2. The effect of using different machines, Doppler modalities, and settings has a considerable influence on the quantification of inflammation by ultrasound in RA patients, and this must be taken into account in multicenter studies. Copyright © 2015 by the American College of Rheumatology.

  3. Comparison of the Diagnostic Performance of Power Doppler Ultrasound and a New Microvascular Doppler Ultrasound Technique (AngioPLUS) for Differentiating Benign and Malignant Breast Masses.

    Science.gov (United States)

    Jung, Hae Kyoung; Park, Ah Young; Ko, Kyung Hee; Koh, Jieun

    2018-03-12

    This study was performed to compare the diagnostic performance of power Doppler ultrasound (US) and a new microvascular Doppler US technique (AngioPLUS; SuperSonic Imagine, Aix-en-Provence, France) for differentiating benign and malignant breast masses. Power Doppler US and AngioPLUS findings were available in 124 breast masses with confirmed pathologic results (benign, 80 [64.5%]; malignant, 44 [35.5%]). The diagnostic performance of each tool was calculated to distinguish benign from malignant masses using a receiver operating characteristic curve analysis and compared. The area under the curve showed that AngioPLUS was superior to power Doppler US in differentiating benign from malignant breast masses, but the difference was not statistically significant. © 2018 by the American Institute of Ultrasound in Medicine.

  4. Doppler Velocimetry of Current Driven Spin Helices in a Two-Dimensional Electron Gas

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Luyi [Univ. of California, Berkeley, CA (United States)

    2013-05-17

    Spins in semiconductors provide a pathway towards the development of spin-based electronics. The appeal of spin logic devices lies in the fact that the spin current is even under time reversal symmetry, yielding non-dissipative coupling to the electric field. To exploit the energy-saving potential of spin current it is essential to be able to control it. While recent demonstrations of electrical-gate control in spin-transistor configurations show great promise, operation at room temperature remains elusive. Further progress requires a deeper understanding of the propagation of spin polarization, particularly in the high mobility semiconductors used for devices. This dissertation presents the demonstration and application of a powerful new optical technique, Doppler spin velocimetry, for probing the motion of spin polarization at the level of 1 nm on a picosecond time scale. We discuss experiments in which this technique is used to measure the motion of spin helices in high mobility n-GaAs quantum wells as a function of temperature, in-plane electric field, and photoinduced spin polarization amplitude. We find that the spin helix velocity changes sign as a function of wave vector and is zero at the wave vector that yields the largest spin lifetime. This observation is quite striking, but can be explained by the random walk model that we have developed. We discover that coherent spin precession within a propagating spin density wave is lost at temperatures near 150 K. This finding is critical to understanding why room temperature operation of devices based on electrical gate control of spin current has so far remained elusive. We report that, at all temperatures, electron spin polarization co-propagates with the high-mobility electron sea, even when this requires an unusual form of separation of spin density from photoinjected electron density. Furthermore, although the spin packet co-propagates with the two-dimensional electron gas, spin diffusion is strongly

  5. Power Doppler sonography and ultrasound contrast agent in assessing rheumatoid synovitis

    Directory of Open Access Journals (Sweden)

    F. Salaffi

    2011-09-01

    Full Text Available Pannus formation is a fundamental event in the pathogenesis of rheumatoid arthritis and its hypervascularisation seems to be crucial to the development of joint damage. High-resolution greyscale ultrasonography is a safe, quick, and inexpensive imaging tool that allows an accurate detection of even minimal morphostructural changes in patients with rheumatoid arthritis, including joint effusion, thickening of synovial membrane and bone erosions. More recently, power Doppler sonography has proved to be a reliable tool for semiquantitative assessment of the vascularity of the synovial tissue. The contrast-enhanced power Doppler sonography seems to be a helpful adjunct in assessing synovitis and the therapeutic response to the different therapies in patients with rheumatoid arthritis. The aim of this radiological vignette was to show a representative example of use of power Doppler sonography with contrast agent in assessing rheumatoid synovitis.

  6. Computer-assisted quantitative assessment of power Doppler US: effects of microbubble contrast agent in the differentiation of breast tumors

    International Nuclear Information System (INIS)

    Kettenbach, Joachim; Helbich, Thomas H.; Huber, Sabine; Zuna, Ivan; Dock, Wolfgang

    2005-01-01

    Rationale and objectives: To objectively quantify the effects of a microbubble contrast agent to differentiate breast tumors with power doppler ultrasound and to compare these results with color doppler ultrasound (CD US). Methods: In 47 patients a microbubble contrast agent was injected intravenously. Computer-assisted quantitative assessment of the color pixel density was performed to evaluate the increase in Doppler signals. Results were compared to previously published results of a color Doppler ultrasound study. Results: Peak color pixel density at contrast-enhanced power Doppler ultrasound was higher for carcinomas than for benign tumors (P < 0.03). Time to peak enhancement was shorter in carcinomas than in benign tumors (P < 0.01). For both parameters, diagnostic accuracy of power Doppler ultrasound was 69 and 78%, and for color Doppler ultrasound 62 and 76%, respectively. Conclusions: Quantitative assessment of contrast-enhanced power Doppler ultrasound showed significant differences in malignant and benign breast tumors. Diagnostic accuracy of contrast-enhanced power Doppler ultrasound was higher compared to color Doppler ultrasound

  7. Contrast-enhanced power Doppler US of hepatocellular carcinomas: Quantitative analysis

    International Nuclear Information System (INIS)

    Kim, Ah Young; Choi, Byung Ihn; Kim, Tae Kyoung; Lee, Kyoung Ho; Han, Joon Koo

    1999-01-01

    To determine peak time and duration of contrast enhancement of nodular hepatocellular carcinoma (HCC) on contrast-enhancement power Doppler ultrasound (US) with Levovist by quantitative analysis. Twenty eight patients with nodular HCC were prospectively evaluated with power Doppler US by one examiner. Serial images were obtained before and after injection of 300 mg/mL US contrast agent (SH U 508 A, Levovist, Schering) with the injection rate of 0.2 mL/sec. Power Doppler signals on obtained digital images were quantified using 'Ultrasound Imaging Tool Version 1.0' (Seoul, Korea). The grade, peak time and duration of contrast enhancement of the tumors were analyzed. For nodular HCCs, mean peak enhancement time was 60 seconds after injection of Levovist (mean enhanced area 41.6 ± 28.6 %). These tumoral enhancement decreased from 90 seconds and returned to near baseline state at 5 minutes after injection of Levovist. Maximum enhanced areas (%) were variable at a range of 8-98.5% and mean maximum enhanced area was 46.4 ± 28.6%. On contrast-enhanced power Doppler US with Levovist, nodular HCCs showed peak contrast enhancement (41.6± 28.6) at 60 seconds after injection of contrast agent. This tumoral enhancement nearly disappeared at 5 minutes after injection of contrast agent.

  8. Results of vardenafil mediated power Doppler ultrasound, contrast enhanced ultrasound and systematic random biopsies to detect prostate cancer.

    Science.gov (United States)

    Morelli, Girolamo; Pagni, Riccardo; Mariani, Chiara; Minervini, Riccardo; Morelli, Andrea; Gori, Francesco; Ferdeghini, Ezio Maria; Paterni, Marco; Mauro, Eva; Guidi, Elisa; Armillotta, Nicola; Canale, Domenico; Vitti, Paolo; Caramella, Davide; Minervini, Andrea

    2011-06-01

    We evaluated the ability of the phosphodiesterase-5 inhibitor vardenafil to increase prostate microcirculation during power Doppler ultrasound. We also evaluated the results of contrast and vardenafil enhanced targeted biopsies compared to those of standard 12-core random biopsies to detect cancer. Between May 2008 and January 2010, 150 consecutive patients with prostate specific antigen more than 4 ng/ml at first diagnosis with negative digital rectal examination and transrectal ultrasound, and no clinical history of prostatitis underwent contrast enhanced power Doppler ultrasound (bolus injection of 2.4 ml SonoVue® contrast agent), followed by vardenafil enhanced power Doppler ultrasound (1 hour after oral administration of vardenafil 20 mg). All patients underwent standard 12-core transrectal ultrasound guided random prostate biopsy plus 1 further sampling from each suspected hypervascular lesion detected by contrast and vardenafil enhanced power Doppler ultrasound. Prostate cancer was detected in 44 patients (29.3%). Contrast and vardenafil enhanced power Doppler ultrasound detected suspicious, contrast enhanced and vardenafil enhanced areas in 112 (74.6%) and 110 patients (73.3%), and was diagnostic for cancer in 32 (28.5%) and 42 (38%), respectively. Analysis of standard technique, and contrast and vardenafil enhanced power Doppler ultrasound findings by biopsy core showed significantly higher detection using vardenafil vs contrast enhanced power Doppler ultrasound and standard technique (41.2% vs 22.7% and 8.1%, p power Doppler ultrasound was 10% and 11.7% (p not significant). Vardenafil enhanced power Doppler ultrasound enables excellent visualization of the microvasculature associated with cancer and can improve the detection rate compared to contrast enhanced power Doppler ultrasound and the random technique. Copyright © 2011 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  9. THREE-DIMENSIONAL DOPPLER TOMOGRAPHY OF THE RS VULPECULAE INTERACTING BINARY

    International Nuclear Information System (INIS)

    Richards, Mercedes T.; Sharova, Olga I.; Agafonov, Michail I.

    2010-01-01

    Three-dimensional Doppler tomography has been used to study the Hα emission sources in the RS Vulpeculae (RS Vul) interacting binary. The two-dimensional tomogram of this binary suggested that most of the emission arises from the cool mass losing star with additional evidence of a gas stream flowing close to its predicted trajectory. However, the three-dimensional tomogram revealed surprising evidence that the gas stream has an average velocity of -85 km s -1 relative to the central velocity plane at V z = 0 km s -1 , unlike U CrB in which the stream was prominent along this central plane. These unexpected V z motions may result from the interaction between magnetic activity on the cool star and the gravitationally induced Roche lobe overflow from that star. Evidence of a loop prominence on the cool star close to the L1 point has been found in the three-dimensional tomogram of RS Vul; hence, the magnetic field lines may have deflected the gas stream relative to the central plane. This result is consistent with earlier detections of RS Vul as both an X-ray and a radio source, and represents the first detection of a loop prominence in an interacting binary based on tomography. Moreover, recent radio images of β Per, the prototype of the Algols, show that the magnetic field of the mass losing star is asymmetric and extends well beyond the orbital plane of the binary, so it is now plausible that the gas flow between the stars in RS Vul could be deflected in an asymmetric way by the magnetic field.

  10. The role of transvaginal power Doppler ultrasound in the differential diagnosis of benign intrauterine focal lesions.

    Science.gov (United States)

    Cogendez, Ebru; Eken, Meryem Kurek; Bakal, Nuray; Gun, Ismet; Kaygusuz, Ecmel Isik; Karateke, Ates

    2015-10-01

    The purpose of this prospective study was to assess the role of power Doppler imaging in the differential diagnosis of benign intrauterine focal lesions such as endometrial polyps and submucous myomas using the characteristics of power Doppler flow mapping. A total of 480 premenopausal patients with abnormal uterine bleeding were evaluated by transvaginal ultrasonography (TVS) searching for intrauterine pathology. Sixty-four patients with a suspicious focal endometrial lesion received saline infusion sonography (SIS) after TVS. Fifty-eight patients with focal endometrial lesions underwent power Doppler ultrasound (PDUS). Three different vascular flow patterns were defined: Single vessel pattern, multiple vessel pattern, and circular flow pattern. Finally, hysteroscopic resection was performed in all cases, and Doppler flow characteristics were then compared with the final histopathological findings. Histopathological results were as follows: endometrial polyp: 40 (69 %), submucous myoma: 18 (31 %). Of the cases with endometrial polyps, 80 % demonstrated a single vessel pattern, 7.5 % a multiple vessel pattern, and 0 % a circular pattern. Vascularization was not observed in 12.5 % of patients with polyps. Of the cases with submucousal myomas, 72.2 % demonstrated a circular flow pattern, 27.8 % a multiple vessel pattern, and none of them showed a single vessel pattern. The sensitivity, specificity, and positive and negative predictive values of the single vessel pattern in diagnosing endometrial polyps were 80, 100, 100, and 69.2 %, respectively; and for the circular pattern in diagnosing submucous myoma, these were 72.2, 100, 100, and 88.9 %, respectively. Power Doppler blood flow mapping is a useful, practical, and noninvasive diagnostic method for the differential diagnosis of benign intrauterine focal lesions. Especially in cases of recurrent abnormal uterine bleeding, recurrent abortion, and infertility, PDUS can be preferred as a first-line diagnostic method.

  11. Fetal cardiac stroke volume determination by four-dimensional ultrasound with spatio-temporal image correlation compared with two-dimensional and Doppler ultrasonography.

    Science.gov (United States)

    Rizzo, Giuseppe; Capponi, Alessandra; Cavicchioni, Ottavia; Vendola, Marianne; Arduini, Domenico

    2007-12-01

    To assess the agreement of stroke volume (SV) measured with two-dimensional (2D) ultrasonography with Doppler capability (vs) four-dimensional (4D) with spatiotemporal image correlation (STIC) in normal and growth restricted fetuses. 2D Doppler and 4D STIC were used to measure SV of 40 normal fetuses at 20 to 22 and 28 to 32 weeks, and 16 growth-restricted fetuses at 26 to 34 weeks of gestation. Intraclass correlation was used to evaluate the agreement between left and right SV obtained by the two techniques, and proportionate Bland-Altman plots constructed. The time necessary to obtain SV was analyzed. The intraclass correlation coefficient between 2D Doppler and 4D STIC measurements for the left ventricle were 0.977 and 0.980 for the right ventricle. The proportionate limits of agreement between the two methods were 18.7 to 23.9% for the left ventricle and - 20.9 to 21.7% for the right ventricle. The time necessary to measure SV was significantly shorter with 4D STIC (3.1 (vs) 7.9 min p < 0.0001) than with 2D Doppler. There is a good agreement between SV measured either by 2D Doppler or by 4D STIC. The 4D STIC represents a simple and rapid technique to estimate fetal SV and promises to become the method of choice. Copyright (c) 2007 John Wiley & Sons, Ltd.

  12. Power Doppler Ultrasound Evaluation of Peripheral Joint, Entheses, Tendon, and Bursa Abnormalities in Psoriatic Patients: A Clinical Study.

    Science.gov (United States)

    Tang, Yuanjiao; Yang, Yujia; Xiang, Xi; Wang, Liyun; Zhang, Lingyan; Qiu, Li

    2018-04-15

    To evaluate the prevalence rates of peripheral joint, enthesis, tendon, and bursa abnormalities by power Doppler (PD) ultrasonic examination in patients with psoriatic arthritis (PsA), psoriatic patients without clinical signs of arthritis (non-PsA psoriasis group), and healthy individuals, to detect subclinical PsA. A total of 253 healthy volunteers, 242 non-PsA psoriatic patients, and 86 patients with PsA were assessed by 2-dimensional and power Doppler (PD) ultrasound. Peripheral joint, enthesis, tendon, and bursa abnormalities were observed, characterizing abnormal PD. The affected patients and sites with abnormalities in various ages were compared among groups; PD signal grades for the abnormalities were also compared. In the PsA group, significantly higher percentages of sites showing joint effusion/synovitis, enthesitis, and tenosynovitis in all age groups, and markedly higher rates of sites with bursitis were found in young and middle age groups, compared with the non-PsA and control groups (all p the non-PsA group showed significantly higher rates of joint effusion/synovitis and enthesitis sites, and elevated PD signal grades of synovitis, enthesitis, and tenosynovitis in comparison with the control group, both in young and middle age groups (all p tenosynovitis.

  13. Two-dimensional color Doppler echocardiography for left ventricular stroke volume assessment: a comparison study with three-dimensional echocardiography.

    Science.gov (United States)

    Silva, Cristina Da; Pedro, Fátima; Deister, Lizandra; Sahlén, Anders; Manouras, Aristomenis; Shahgaldi, Kambiz

    2012-08-01

    Whether measurement of left ventricular outflow tract diameter (LVOTd) using color Doppler (CD) in order to more accurately define LVOTd is more accurate for determination of stroke volume (SV) than gray scale and compare it with direct measurement of LVOT area (a) using three-dimensional echocardiography (3DE) for SV determination. Twenty-one volunteers were examined. LVOTa was calculated by two-dimensional echocardiography (2DE) using the following formula: π× (d/2)(2) , d = LVOT diameter by gray scale and CD, respectively. Planimetry of LVOTa was performed in parasternal long axis using 3DE. Eccentricity Index was calculated using the lateral and anterior-posterior LVOTd. SV was obtained by four different methods: (1) 2D gray scale, (2) 2D color, (3) LVOTa × LVOT velocity time integral, and (4) SV by Simpson's biplane method. Gray scale LVOTd was significantly smaller compared to LVOTd obtained with CD (P vs 3.67 ± 0.70 cm(2) , P vs 3.61 ± 0.89 cm(2) , P = 0.011). Half of the subjects had at least 17% difference between the lateral and anterior-posterior LVOTd. There were significant differences between SV by 2D gray scale and 2D CD (82.8 ± 17.1 mL vs 92.4 ± 16.8 mL, P vs 90.7 ± 19.8 mL, P = 0.025). Our study demonstrates LVOT being frequently elliptical. SV and LVOTa were found to be similar when comparing 2DE CD and 3DE planimetry and showed higher values in comparison to 2DE gray scale, which suggests 2DE CD to be an alternative approach for SV assessment. © 2012, Wiley Periodicals, Inc.

  14. Study on application of Doppler SODAR as meteorological observation tool at nuclear power plant

    International Nuclear Information System (INIS)

    Katayose, Naoto; Akai, Yukio.

    1993-01-01

    Among the remote sensing devices usable for meteorological observation, which became possible with the advent of modern science and technology, Doppler SODAR was selected for further study aimed at its practical application for nuclear power plants. This device was installed for testing purpose at a Japanese nuclear power and data collection (wind speed and direction) was carried out throughout one year there. The data on the selected SODAR have shown a correlation with those collected by the conventional method which is good enough to justify the SODAR's practical use at nuclear power plants. (author)

  15. Angiosonography in suspicious breast lesions with non-diagnostic FNAC: comparison with power Doppler US.

    Science.gov (United States)

    Caumo, F; Carbognin, G; Casarin, A; Pinali, L; Vasori, S; D'Onofrio, M; Pozzi Mucelli, R

    2006-02-01

    The purpose of this study was to evaluate the accuracy of angiosonography in comparison with colour Doppler ultrasound (US) in the discrimination of suspicious breast lesions with nondiagnostic fine-needle aspiration cytology (FNAC). Pre-operative Power Doppler US and angiosonography were prospectively performed in 20 suspicious breast lesions with non-diagnostic FNAC. A second-generation US contrast agent was utilised with a high-frequency transducer and a contrast-specific algorithm (low acoustic pressure CnTI). The enhancement characteristics of all lesions were analysed using qualitative and quantitative parameters obtained from time-intensity curves with the different imaging modalities. The final diagnosis was confirmed at pathology in all cases. Microvessel density (MVD) was assessed in the surgical specimen using CD34. The correct assessment of biological behaviour was achieved in all cases by angiosonography (sensitivity of 100%; specificity of 91%) and colour Doppler US (45% sensitivity; 78% specificity). MVD correlated with the biological behaviour. Angiosonography is more accurate than colour Doppler US in the correct assessment of biological behaviour of suspicious breast lesions.

  16. Flow angle dependent photoacoustic Doppler power spectra under intensity-modulated continuous wave laser excitation

    Directory of Open Access Journals (Sweden)

    Yu Tong

    2016-02-01

    Full Text Available Photoacoustic Doppler (PAD power spectra showing an evident Doppler shift represent the major characteristics of the continuous wave-excited or burst wave-excited versions of PAD flow measurements. In this paper, the flow angle dependences of the PAD power spectra are investigated using an experiment setup that was established based on intensity-modulated continuous wave laser excitation. The setup has an overall configuration that is similar to a previously reported configuration, but is more sophisticated in that it accurately aligns the laser illumination with the ultrasound detection process, and in that it picks up the correct sample position. In the analysis of the power spectra data, we find that the background power spectra can be extracted by combining the output signals from the two channels of the lock-in amplifier, which is very useful for identification of the PAD power spectra. The power spectra are presented and analyzed in opposite flow directions, at different flow speeds, and at different flow angles. The power spectra at a 90° flow angle show the unique properties of symmetrical shapes due to PAD broadening. For the other flow angles, the smoothed power spectra clearly show a flow angle cosine relationship.

  17. Dynamics of contrast enhancement in MR imaging and power Doppler ultrasonography of solid breast lesions

    International Nuclear Information System (INIS)

    Reinikainen, H.; Paeaekkoe, E.; Suramo, I.; Paeivaensalo, M.; Rissanen, T.

    2002-01-01

    Purpose: To evaluate the dynamics of contrast enhancement in solid breast lesions at contrast-enhanced MR imaging and power Doppler ultrasonography (US) and to compare the methods to histology and to each other. Material and Methods: Forty breast lesions were prospectively examined with dynamic MR and power Doppler US. Time-signal intensity curves of enhancement were obtained for both methods. The shape of the curve was analyzed to be benign, indeterminate or malignant. The curves were also analyzed quantitatively by calculating the slope of the curve and the area under the curve (both methods), relative enhancement (MR), and time to peak (US). The lesions were divided into malignant lesions, fibroadenomas, and other benign lesions. The results were compared to histology. Results: In the subjective analysis of the MR curve in differentiating between benign and malignant lesions the accuracy was 90%. The MR curve also enabled differentiation between fibroadenomas and malignancies. The accuracy of the US curve was 38%. Quantitatively, statistically significant differences were found using all the MR variables, except between malignancies and fibroadenomas. Using the US variables, no significant difference was found between the groups. Conclusion: The dynamics of contrast-enhanced MR were reliable in the differential diagnosis of solid breast lesions, but contrast-enhanced power Doppler US was of limited value

  18. Color/power Doppler transrectal US in prostate cancer: Correlation with Gleason score

    International Nuclear Information System (INIS)

    Kim, Hyo Cheol; Kim, Seung Hyup; Moon, Min Hoan; Park, Byung Kwan; Kim, Keon Ha; Choi, Hyuck Jae; Yoon, Chang Jin

    2002-01-01

    To evaluate the relationship between hypervascularity on color/power Doppler transrectal ultrasonography and the Gleason score of corresponding biopsied specimen in patients with prostatic cancer. From July 1998 to March 2002, one hundred fifty seven patients with pathologically proven prostate cancer at this institution were included, and all of them underwent transrectal ultrasonographic examination. Initially, ultrasonographic findings and pathologic data of 129 patients were retrospectively reviewed and excluded 28 patients whose sonographic images were either unavailable or inconclusive. The presence of hypoechoic lesion on transrectal sonography and hypervascularity on color/power Doppler sonography in the peripheral zone of the prostate was first evaluated, and these sonographic findings and Gleason score of the corresponding biopsied specimen were then compared. Statistical analysis was done by Student t-test using SPSS package. Among one hundred twenty nine patients, ninety four patients had a hypoechoic lesion on gray scale sonography while sixty one showed a hypervascular lesion on color/power Doppler sonography. Fifty seven of 61 patients (93.4%) had hypoechoic lesion on gray scale sonography. The mean Gleason score of patients with hypervascular lesion was 7.9 ± 0.98 whereas that of the patients without hypervascular lesion, 6.9 ± 1.22, showing a statistically significant difference (p<0.01). Prostate cancer with hypervascularity on transrectal sonography appears to have a higher Gleason score on pathologic examination than that without hypervascularity.

  19. The effect of blood acceleration on the ultrasound power Doppler spectrum

    Science.gov (United States)

    Matchenko, O. S.; Barannik, E. A.

    2017-09-01

    The purpose of the present work was to study the influence of blood acceleration and time window length on the power Doppler spectrum for Gaussian ultrasound beams. The work has been carried out on the basis of continuum model of the ultrasound scattering from inhomogeneities in fluid flow. Correlation function of fluctuations has been considered for uniformly accelerated scatterers, and the resulting power Doppler spectra have been calculated. It is shown that within the initial phase of systole uniformly accelerated slow blood flow in pulmonary artery and aorta tends to make the correlation function about 4.89 and 7.83 times wider, respectively, than the sensitivity function of typical probing system. Given peak flow velocities, the sensitivity function becomes, vice versa, about 4.34 and 3.84 times wider, respectively, then the correlation function. In these limiting cases, the resulting spectra can be considered as Gaussian. The optimal time window duration decreases with increasing acceleration of blood flow and equals to 11.62 and 7.54 ms for pulmonary artery and aorta, respectively. The width of the resulting power Doppler spectrum is shown to be defined mostly by the wave vector of the incident field, the duration of signal and the acceleration of scatterers in the case of low flow velocities. In the opposite case geometrical properties of probing field and the average velocity itself are more essential. In the sense of signal-noise ratio, the optimal duration of time window can be found. Abovementioned results may contribute to the improved techniques of Doppler ultrasound diagnostics of cardiovascular system.

  20. Power Doppler ultrasonography and synovitis: correlating ultrasound imaging with histopathological findings and evaluating the performance of ultrasound equipments.

    Science.gov (United States)

    Koski, J M; Saarakkala, S; Helle, M; Hakulinen, U; Heikkinen, J O; Hermunen, H

    2006-12-01

    To examine the validity of power Doppler ultrasound imaging to identify synovitis, using histopathology as gold standard, and to assess the performance of ultrasound equipments. 44 synovial sites in small and large joints, bursae and tendon sheaths were depicted with ultrasound. A synovial biopsy was performed on the site depicted and a synovial sample was taken for histopathological evaluation. The performance of three ultrasound devices was tested using flow phantoms. A positive Doppler signal was detected in 29 of 35 (83%) of the patients with active histological inflammation. In eight additional samples, histological examination showed other pathological synovial findings and a Doppler signal was detected in five of them. No significant correlation was found between the amount of Doppler signal and histological synovitis score (r = 0.239, p = NS). The amount of subsynovial infiltration of polymorphonuclear leucocytes and surface fibrin correlated significantly with the amount of power Doppler signal: r = 0.397 (pultrasound devices differed in showing the smallest detectable flow. A negative Doppler signal does not exclude the possibility of synovitis. A positive Doppler signal in the synovium is an indicator of an active synovial inflammation in patients. A Doppler signal does not correlate with the extent of the inflammation and it can also be seen in other synovial reactions. It is important that the quality measurements of ultrasound devices are reported, because the results should be evaluated against the quality of the device used.

  1. Three-dimensional Doppler ultrasound findings in healthy wrist and finger tendon sheaths

    DEFF Research Database (Denmark)

    Ammitzboll-Danielsen, Mads; Janta, Iustina; Torp-Pedersen, Søren

    2016-01-01

    interpretation of Doppler signals when diagnosing tenosynovitis. Method Forty healthy participants (20 women and 20 men age 23-67 years) without prior history of arthritis, tendon diseases or present pain in their hands were included. Twenty participants had 3D Doppler US of the second and third finger...... participant. No significant difference in feeding vessels was seen between the radial and carpal level in the wrist (p = 0.06) or between the second and third flexor tendon sheath (p = 0.84). Conclusion Doppler findings in or in close proximity to the tendon sheaths were common in wrists and fingers...

  2. 99m-Tc DMSA scintigraphy and color/power doppler sonography for children pyelonephritis diagnosis and follow-up

    International Nuclear Information System (INIS)

    Hitzel, A.; Manrique, A.; Gardin, I.; Vera, P.; Hitzel, A.; Dacher, J.N.; Manrique, A.; Menard, J.F.; Gardin, I.; Vera, P.; Dacher, J.N.; Liard, A.; Menard, J.F.

    2004-01-01

    Early diagnosis of acute pyelonephritis is essential to avoid scarring development. This study was performed to evaluate capabilities of color/doppler sonography to detect pyelonephritis and to predict scarring when compared with 99m Tc-DMSA scintigraphy. Fifty-seven children were evaluated during pyelonephritis: biology (CRP, creatinine, blood formula), color/power doppler sonography and 99m Tc-DMSA scintigraphy (DMSA1). 7 ± 2 months later, follow-up consisted in biological tests and a 99m 'Tc-DMSA scintigraphy (DMSA2). During pyelonephritis, body temperature, CRP value and neutrophil counts were significantly higher in patients with an abnormal DMSA1 but not in patients with abnormal doppler sonography. When compared with DMSA1, doppler sonography sensitivity and specificity were 80% and 81% respectively. DMSA1 and doppler sonography were concordant in 86% of children with a pyelonephritis. At follow-up, all clinical et biological parameters were normalized. DMSA2 was abnormal in 51% of children. When compared with DMSA2, positive and negative predictive values for scarring of doppler sonography were 57% and 75% respectively. DMSA 1, positive and negative predictive values for scarring were 62% and 100%. In conclusion, color/power doppler sonography is a reliable tool for pyelonephritis diagnosis, but its predictive value for scarring is poor. Negative predictive value of DMSA scintigraphy is excellent. (author)

  3. Evaluation of the relationship between renal function and renal volume-vascular indices using 3D power Doppler ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Cansu, Aysegul, E-mail: drcansu@gmail.com; Kupeli, Ali; Kul, Sibel; Eyuboglu, Ilker; Oguz, Sukru; Ozturk, Mehmet Halil; Dinc, Hasan

    2014-07-15

    Purpose: To investigate the relationship between renal function and total renal volume-vascular indices using 3D power Doppler ultrasound (3DPDUS). Materials and methods: One hundred six patients with hypertensive proteinuric nephropathy (HPN) (49 male, 57 female) and 65 healthy controls (32 male, 33 female) were evaluated prospectively using 3DPDUS. Total renal volume (RV), vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were calculated using Virtual Organ Computer-aided Analysis (VOCAL). The estimated glomerular filtration rates (GFRs) of the patients with HPN and the control group were calculated. The patients with HPN were divided into two groups on the basis of GFR, normal (≥90) or reduced (<90). Differences between groups were compared using ANOVA. Correlations between GFR, renal volume and vascular indices were analyzed using Pearson's correlation analysis. Significance was set at p < 0.05. Results: The mean total RV, VI, FI and VFI values in the reduced GFR, normal GFR and control groups were RV (ml): 234.7, 280.7 and 294.6; VI: 17.6, 27.6 and 46.8; FI: 79.1, 88.7 and 93.9 and VFI: 7.1, 12.7 and 23.8. There were statistically significant differences between the groups (p < 0.001). Total RVs and vascular indices exhibited significant correlations with estimated GFR (r = 0.53–0.59, p < 0.001) Conclusion: Three-dimensional power Doppler ultrasound is a reliable predictive technique in renal function analysis.

  4. Two-dimensional intraventricular flow mapping by digital processing conventional color-Doppler echocardiography images.

    Science.gov (United States)

    Garcia, Damien; Del Alamo, Juan C; Tanne, David; Yotti, Raquel; Cortina, Cristina; Bertrand, Eric; Antoranz, José Carlos; Perez-David, Esther; Rieu, Régis; Fernandez-Aviles, Francisco; Bermejo, Javier

    2010-10-01

    Doppler echocardiography remains the most extended clinical modality for the evaluation of left ventricular (LV) function. Current Doppler ultrasound methods, however, are limited to the representation of a single flow velocity component. We thus developed a novel technique to construct 2D time-resolved (2D+t) LV velocity fields from conventional transthoracic clinical acquisitions. Combining color-Doppler velocities with LV wall positions, the cross-beam blood velocities were calculated using the continuity equation under a planar flow assumption. To validate the algorithm, 2D Doppler flow mapping and laser particle image velocimetry (PIV) measurements were carried out in an atrio-ventricular duplicator. Phase-contrast magnetic resonance (MR) acquisitions were used to measure in vivo the error due to the 2D flow assumption and to potential scan-plane misalignment. Finally, the applicability of the Doppler technique was tested in the clinical setting. In vitro experiments demonstrated that the new method yields an accurate quantitative description of the main vortex that forms during the cardiac cycle (mean error for vortex radius, position and circulation). MR image analysis evidenced that the error due to the planar flow assumption is close to 15% and does not preclude the characterization of major vortex properties neither in the normal nor in the dilated LV. These results are yet to be confirmed by a head-to-head clinical validation study. Clinical Doppler studies showed that the method is readily applicable and that a single large anterograde vortex develops in the healthy ventricle while supplementary retrograde swirling structures may appear in the diseased heart. The proposed echocardiographic method based on the continuity equation is fast, clinically-compliant and does not require complex training. This technique will potentially enable investigators to study of additional quantitative aspects of intraventricular flow dynamics in the clinical setting by

  5. 3D power Doppler ultrasound assessment of placental perfusion during uterine contraction in labor.

    Science.gov (United States)

    Sato, Miki; Noguchi, Junko; Mashima, Masato; Tanaka, Hirokazu; Hata, Toshiyuki

    2016-09-01

    To assess placental perfusion during spontaneous or induced uterine contraction in labor at term using placental vascular sonobiopsy (PVS) by 3D power Doppler ultrasound with the VOCAL imaging analysis program. PVS was performed in 50 normal pregnancies (32 in spontaneous labor group [SLG], and 18 in induced labor group with oxytocin or prostaglandin F2α [ILG]) at 37-41 weeks of gestation to assess placental perfusion during uterine contraction in labor. Only pregnancies with an entirely visualized anterior placenta were included in the study. Data acquisition was performed before, during (at the peak of contraction), and after uterine contraction. 3D power Doppler indices such as the vascularization index (VI), flow index (FI), and vascularization flow index (VFI) were calculated in each placenta. There were no abnormal fetal heart rate tracings during contraction in either group. VI and VFI values were significantly reduced during uterine contraction in both groups (SLG, -33.4% [-97.0-15.2%], and ILG, -49.6% [-78.2--4.0%]), respectively (P power Doppler indices (VI, FI, and VFI) during uterine contraction (at the peak of contraction) showed a correlation greater than 0.7, with good intra- and inter-observer agreements. Our findings suggest that uterine contraction in both spontaneous and induced labors causes a significant reduction in placental perfusion. Reduced placental blood flow in induced uterine contraction has a tendency to be marked compared with that in spontaneous uterine contraction. To the best of our knowledge, this is the first study on the non-invasive assessment of placental perfusion during uterine contraction in labor using 3D power Doppler ultrasound. However, the data and their interpretation in the present study should be taken with some degree of caution because of the small number of subjects studied. Further studies involving a larger sample size are needed to assess placental perfusion and vascularity using PVS during normal and

  6. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    Science.gov (United States)

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  7. Experimental and biological variation of three-dimensional transcranial Doppler measurements

    DEFF Research Database (Denmark)

    Thomsen, L L; Iversen, Helle Klingenberg

    1993-01-01

    A new transcranial Doppler system (3-D Transscan, Eden Medizinische Elektronik) was evaluated in relation to sex, age, intersubject, interobserver, side-to-side, and day-to-day variation. Fifty-eight healthy volunteers participated (aged 18-80 yr). Mean velocity was higher in females than in male...

  8. Determining radiated sound power of building structures by means of laser Doppler vibrometry

    Science.gov (United States)

    Roozen, N. B.; Labelle, L.; Rychtáriková, M.; Glorieux, C.

    2015-06-01

    This paper introduces a methodology that makes use of laser Doppler vibrometry to assess the acoustic insulation performance of a building element. The sound power radiated by the surface of the element is numerically determined from the vibrational pattern, offering an alternative for classical microphone measurements. Compared to the latter the proposed analysis is not sensitive to room acoustical effects. This allows the proposed methodology to be used at low frequencies, where the standardized microphone based approach suffers from a high uncertainty due to a low acoustic modal density. Standardized measurements as well as laser Doppler vibrometry measurements and computations have been performed on two test panels, a light-weight wall and a gypsum block wall and are compared and discussed in this paper. The proposed methodology offers an adequate solution for the assessment of the acoustic insulation of building elements at low frequencies. This is crucial in the framework of recent proposals of acoustic standards for measurement approaches and single number sound insulation performance ratings to take into account frequencies down to 50 Hz.

  9. Power spectral density of velocity fluctuations estimated from phase Doppler data

    Science.gov (United States)

    Jedelsky, Jan; Lizal, Frantisek; Jicha, Miroslav

    2012-04-01

    Laser Doppler Anemometry (LDA) and its modifications such as PhaseDoppler Particle Anemometry (P/DPA) is point-wise method for optical nonintrusive measurement of particle velocity with high data rate. Conversion of the LDA velocity data from temporal to frequency domain - calculation of power spectral density (PSD) of velocity fluctuations, is a non trivial task due to nonequidistant data sampling in time. We briefly discuss possibilities for the PSD estimation and specify limitations caused by seeding density and other factors of the flow and LDA setup. Arbitrary results of LDA measurements are compared with corresponding Hot Wire Anemometry (HWA) data in the frequency domain. Slot correlation (SC) method implemented in software program Kern by Nobach (2006) is used for the PSD estimation. Influence of several input parameters on resulting PSDs is described. Optimum setup of the software for our data of particle-laden air flow in realistic human airway model is documented. Typical character of the flow is described using PSD plots of velocity fluctuations with comments on specific properties of the flow. Some recommendations for improvements of future experiments to acquire better PSD results are given.

  10. Power spectral density of velocity fluctuations estimated from phase Doppler data

    Directory of Open Access Journals (Sweden)

    Jicha Miroslav

    2012-04-01

    Full Text Available Laser Doppler Anemometry (LDA and its modifications such as PhaseDoppler Particle Anemometry (P/DPA is point-wise method for optical nonintrusive measurement of particle velocity with high data rate. Conversion of the LDA velocity data from temporal to frequency domain – calculation of power spectral density (PSD of velocity fluctuations, is a non trivial task due to nonequidistant data sampling in time. We briefly discuss possibilities for the PSD estimation and specify limitations caused by seeding density and other factors of the flow and LDA setup. Arbitrary results of LDA measurements are compared with corresponding Hot Wire Anemometry (HWA data in the frequency domain. Slot correlation (SC method implemented in software program Kern by Nobach (2006 is used for the PSD estimation. Influence of several input parameters on resulting PSDs is described. Optimum setup of the software for our data of particle-laden air flow in realistic human airway model is documented. Typical character of the flow is described using PSD plots of velocity fluctuations with comments on specific properties of the flow. Some recommendations for improvements of future experiments to acquire better PSD results are given.

  11. Contrast-enhanced power Doppler ultrasonography of the metacarpophalangeal joints in rheumatoid arthritis

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, Michel; Strandberg, Charlotte

    2003-01-01

    The aim of this study was to examine, with dynamic contrast-enhanced MRI as the reference, if contrast-enhanced power Doppler ultrasonography (CE PDUS) of rheumatoid arthritis (RA) metacarpophalangeal (MCP) joints provides additional information for evaluation of synovial inflammation compared...... with PDUS. One MCP joint in each of 15 RA patients and 3 healthy control persons were examined with PDUS before and after intravenous bolus Levovist contrast injection. Corresponding rates of early synovial enhancement (RESE), previously shown to be closely related to histopathological synovitis, were...... calculated from dynamic contrast-enhanced MR images obtained the same day. Prior to ultrasonography, the joint was evaluated clinically. Levovist increased the flow signal in 7 of 9 joints with pre-contrast flow-signal and in 0 of 9 without pre-contrast signal. No healthy controls showed CE PDUS signal...

  12. A method to validate quantitative high-frequency power doppler ultrasound with fluorescence in vivo video microscopy.

    Science.gov (United States)

    Pinter, Stephen Z; Kim, Dae-Ro; Hague, M Nicole; Chambers, Ann F; MacDonald, Ian C; Lacefield, James C

    2014-08-01

    Flow quantification with high-frequency (>20 MHz) power Doppler ultrasound can be performed objectively using the wall-filter selection curve (WFSC) method to select the cutoff velocity that yields a best-estimate color pixel density (CPD). An in vivo video microscopy system (IVVM) is combined with high-frequency power Doppler ultrasound to provide a method for validation of CPD measurements based on WFSCs in mouse testicular vessels. The ultrasound and IVVM systems are instrumented so that the mouse remains on the same imaging platform when switching between the two modalities. In vivo video microscopy provides gold-standard measurements of vascular diameter to validate power Doppler CPD estimates. Measurements in four image planes from three mice exhibit wide variation in the optimal cutoff velocity and indicate that a predetermined cutoff velocity setting can introduce significant errors in studies intended to quantify vascularity. Consistent with previously published flow-phantom data, in vivo WFSCs exhibited three characteristic regions and detectable plateaus. Selection of a cutoff velocity at the right end of the plateau yielded a CPD close to the gold-standard vascular volume fraction estimated using IVVM. An investigator can implement the WFSC method to help adapt cutoff velocity to current blood flow conditions and thereby improve the accuracy of power Doppler for quantitative microvascular imaging. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. The predictive value of three-dimensional Doppler ultrasonography in determining implantation in patients underwent in vitro fertilization

    Directory of Open Access Journals (Sweden)

    Yusuf Çakmak

    2015-12-01

    Full Text Available Objective: The aim of this study is to evaluate the relationship between endometrial and sub-endometrial blood flow and implantation rate in patients whose undergone in vitro fertilization. Methods: A prospective study was conducted. Long protocol and antagonist regimens were administered to the patients. Endometrial and sub-endometrial blood flow was evaluated by using 3 dimensional Doppler ultrasonography on the day of oocyt retrieval measurement. For comparison pregnant and non-pregnant women in terms of endometrial and sub-endometrial blood flow, t test was used. The p value was considered statistically meaningful as 0.05. In long protocol group, the number of embryo was greater in pregnant women than non-pregnant women (p=0.012. The number of transferred embryo increased pregnancy rate almost 3.5 fold (p=0.002. Conclusion: The endometrial and subendometrial blood flow is not reliable factor in prediction pregnancy or implantation.

  14. Ultrasound resistive index, power Doppler, and clinical parameters in established rheumatoid arthritis.

    Science.gov (United States)

    Bisi, Melissa Cláudia; do Prado, Aline Defaveri; Piovesan, Deise Marcela; Bredemeier, Markus; da Silveira, Inês Guimarães; Mendonça, José Alexandre; Staub, Henrique Luiz

    2017-04-01

    Ultrasonography (US) is a useful tool for the evaluation of sinovial vascularization and proliferation in rheumatoid arthritis (RA). Accordingly, resistive index (RI) on spectral Doppler (sD) US provides a quantitative analysis of vascular inflammation, but its utility in the evaluation of RA activity has not been established. Our objective was to determine the association of RI with other US parameters of synovitis and with clinical disease activity in established RA. Patients with positive power Doppler (pD) were included in a prospective cross-sectional study. Disease activity and disability were evaluated using the Disease Activity Score in 28-joints (DAS28) and Health Assessment Questionnaire (HAQ), respectively. Gray scale (GS) synovitis, pD, and sD analyses were performed by one of two examiners in wrists and the second and third metacarpophalangeal and proximal interphalangeal joints. The 10-joint GS and 10-joint pD scores and mean RI were then calculated. Weighted kappa (WK) values were employed to assess interobserver reability, and correlations were tested using the Spearman coefficient. Ninety-five RA patients (median duration of disease of 7 years and mean DAS28 of 4.32 ± 1.66) were included. WK values in real-time US were 0.77 for synovitis, 0.87 for pD, and 0.68 for RI. There were no significant correlations of RI with 10-joint GS, 10-joint pD, DAS28, joint counts, or HAQ (P > 0.10 for all tests). Patients in remission had a mean RI similar to those with high disease activity (0.62 ± 0.10, n = 15 versus 0.63 ± 0.13, n = 34, respectively). The addition of the RI score did not seem to improve US performance in patients with established RA.

  15. The deconvolution of Doppler-broadened positron annihilation measurements using fast Fourier transforms and power spectral analysis

    International Nuclear Information System (INIS)

    Schaffer, J.P.; Shaughnessy, E.J.; Jones, P.L.

    1984-01-01

    A deconvolution procedure which corrects Doppler-broadened positron annihilation spectra for instrument resolution is described. The method employs fast Fourier transforms, is model independent, and does not require iteration. The mathematical difficulties associated with the incorrectly posed first order Fredholm integral equation are overcome by using power spectral analysis to select a limited number of low frequency Fourier coefficients. The FFT/power spectrum method is then demonstrated for an irradiated high purity single crystal sapphire sample. (orig.)

  16. Contrast-enhanced power Doppler endosonography and pathological assessment of vascularization in advanced gastric carcinomas--a feasibility study.

    Science.gov (United States)

    Iordache, Sevastiţa; Filip, Maria-Monalisa; Georgescu, Claudia-Valentina; Angelescu, Cristina; Ciurea, Tudorel; Săftoiu, Adrian

    2012-06-01

    Besides representing angiogenesis markers, microvascular density (MVD) and vascular endothelial growth factor (VEGF) are two important tools for the assessment of prognosis in patients with gastric cancer. The aim of our study was to assess the Doppler parameters (resistivity and pulsatility indexes) and vascularity index (VI) calculated by contrast-enhanced power Doppler endoscopic ultrasound (CEPD-EUS) in correlation with the expression of intra-tumoral MVD and VEGF in patients with gastric cancer. The study included 20 consecutive patients with advanced gastric carcinoma, but without distant metastasis at initial assessment. All the patients were assessed by contrast-enhanced power Doppler endoscopic ultrasound (EUS) combined with pulsed Doppler examinations in the late venous phase. The vascularity index (VI) was calculated before and after injection of second generation microbubble contrast specific agent (SonoVue 2.4 mL), used as a Doppler signal enhancer. Moreover, pulsed Doppler parameters (resistivity and pulsatility indexes) were further calculated. The correlation between power Doppler parameters and pathological/molecular parameters (MVD assessed through immunohistochemistry with CD31 and CD34, as well as VEGF assessed through real-time PCR) was assessed. Kaplan-Meier survival analysis was used for the assessment of prognosis. Significantly statistical correlations were found between post-contrast VI and CD34 (p=0.0226), VEGF (p=0.0231), VEGF-A (p=0.0464) and VEGF-B (p=0.0022) while pre-contrast VI was correlated only with CD34 expression. Pulsatility index and resistivity index were not correlated with MVD or VEGF expression. Survival analysis demonstrated that VEGF-A is an accurate parameter for survival rate (p=0.045), as compared to VEGF (p=0.085) and VEGF-B (p=0.230). We did not find any correlation between the survival rate and ultrasound parameters (RI, PI, pre-contrast VI or post-contrast VI). Assessment of tumor vascularity using contrast

  17. Color Doppler, power Doppler and B-flow ultrasound in the assessment of ICA stenosis: Comparison with 64-MD-CT angiography

    International Nuclear Information System (INIS)

    Clevert, D.A.; Johnson, T.; Flach, P.M.; Strautz, T.I.; Becker, C.; Reiser, M.; Jung, E.M.; Ritter, G.; Gallegos, M.T.; Kubale, R.

    2007-01-01

    The purpose of this study is to investigate the diagnostic potential of color-coded Doppler sonography (CCDS), power-Doppler (PD) and B-flow ultrasound in assessing the degree of extracranial internal carotid artery (ICA) stenosis in comparison to CT-angiography (MD-CTA). Thirty-two consecutive patients referred for CTA with 41 ICA-stenoses were included in this prospective study. MD-CTA was performed using a 64 row scanner with a CTDIvol of 13.1 mGy/cm. In CTA, CCDS, PD and B-flow, the degree of stenosis was evaluated by the minimal intrastenotic diameter in comparison to the poststenotic diameter. Two radiologists performed a quantitative evaluation of the stenoses in consensus blinded to the results of ultrasound. These were correlated to CTA, CCDS, PD and B-flow, intraoperative findings and clinical follow-up. Grading of the stenoses in B-flow ultrasound outperformed the other techniques in terms of accuracy with a correlation coefficient to CTA of 0.88, while PD and CCDS measurements yield coefficients of 0.74 and 0.70. Bland-Altman analysis additionally shows a very little bias of the three US methods between 0.5 and 3.2 %. There is excellent correlation (coefficient 0.88, CI 0.77-0.93) with 64-MD-CTA and B-flow ultrasound in terms of accuracy for intrastenotic and poststenotic diameter. Duplex sonography is useful for screening purposes. (orig.)

  18. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  19. Musculoskeletal colour/power Doppler in sports medicine: image parameters, artefacts, image interpretation and therapy

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, Mikael; Kønig, Merete Juhl

    2011-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  20. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun [College of Medicine, Seoul National Univ., Seoul (Korea, Republic of)

    2002-05-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination.

  1. Tumor vascularity of experimentally induced VX2 carcinoma in the rabbit thigh: evaluation with enhanced power doppler sonography and DSA correlated with histopathologic findings

    International Nuclear Information System (INIS)

    Kim, Young Hoon; Han, Joon Koo; Chung, Jin Wook; Lee, Kyoung Ho; Kim, Se Hyung; Kim, Seog Joon; Choi, Byung Ihn; Chang, Kee Hyun

    2002-01-01

    To describe findings of enhanced power Doppler sonography and DSA in experimentally induced VX2 carcinomas in rabbit thigh and to correlate the imaging findings with the histopathologic features. A total of 30 VX2 carcinomas were implanted in rabbit thigh, and after conventional and enhanced power Doppler sonography and DSA, histopathologic examination was performed. Enhanced power Doppler sonography and DSA, were used to determine the distribution pattern of tumor vascularity; to assess its grade and the percentage of a tumor area occupied by vessels, conventional and enhanced power Doppler sonography, as well as DSA, were used. The grade of necrosis and the development of fibrovascular stroma and capsule were histopathologically determined. The findings of power Doppler sonography were compared with those of DSA and the imaging features were correlated with the histopathologic features. At enhanced power Doppler sonography, the signal was either avascular (n=9), peripheral (n=15) or diffuse (n=6), while at DSA, the corresponding totals were eight, fourteen and eight. There was statistically significant corelation between enhanced power Doppler sonogrpahy and DSA, both in their depiction of the distribution of patterns of tumor vascularity and as regards their findings of grade and percentage of vascular area. As determined by both conventional and enhanced power Doppler sonogrpahy, and by DSA, grade of necrosis and the development of fibrovascular stroma and a capsule correlated with grade and the percentage of vascular area. Experimentally induced VX2 carcinomas in rabbit thigh demonstrated various patterns of tumor vascularity, and the findings of enhanced power Doppler sonography correlated with those of DSA. Tumor vascularity, as demonstrated by two imaging modalities, correlated closely with grade of necrosis and the development of fibrovascular stroma and a capsule, as revealed by histopathologic examination

  2. Power Doppler Imaging in Acute Renal Vein Occlusion and Recanalization: a Canine Model

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, So-Young; Kim, In-One; Kim, Young-Il; Lee, Kyoung Ho; Lee, Min Woo; Youn, Byung Jae; Kim, Woo Sun; Yeon, Kyung Mo [Seoul National University College of Medicine, Seoul (Korea, Republic of)

    2008-04-15

    Objective : To evaluate the dynamic changes of the power Doppler (PD) in acute renal vein occlusion and recanalization in a canine model. Materials and Methods : We performed a PD of the kidney during graded renal vein occlusion and recanalization induced by balloon inflation and deflation in nine dogs. The PD images were transferred to a personal computer, and the PD signals were quantified. Result : We observed the temporal change of the PD signal during renal vein occlusion and recanalization, with a decrease in the PD signal during occlusion and an increase during recanalization. The mean PD signal decreased gradually as the renal vein was occluded, and conversely increased gradually with sequential relief of occlusion. The sequential change of the mean value of the PD signal was statistically significant. Conclusion : The PD can detect a change in renal blood flow during acute renal vein occlusion and recanalization in a canine model. The PD may be used as a helpful tool for the early detection of acute renal vein thrombosis and the monitoring of renal perfusion.

  3. Is articular pain in rheumatoid arthritis correlated with ultrasound power Doppler findings?

    Science.gov (United States)

    Pereira, Daniele Freitas; Gutierrez, Marwin; de Buosi, Ana Leticia Pirozzi; Ferreira, Fernando Bernardes Maia Diniz; Draghessi, Antonella; Grassi, Walter; Natour, Jamil; Furtado, Rita Nely Vilar

    2015-11-01

    The study is addressed to determine if there is a correlation between intra-articular power Doppler (PD) and pain symptoms in patients with rheumatoid arthritis (RA). A cross-sectional study of patients with established RA was rolled out. Seventy-two patients with chronic swelling at metacarpophalangeal (MCP) joints were consecutively enrolled in the study and divided into two groups (painful and painless). In the painful group, the inclusion criteria were pain in the visual analog scale (VAS), from 0 to 10 cm, of at least 4 cm and 0 in the painless group. All two to five MCP joints, bilaterally, were scanned by ultrasound (US) searching for intra-articular PD presence. Any value of p painful group had longer morning stiffness, worse 28-joint disease activity score (DAS 28), and health assessment questionnaire (HAQ) indexes. There were no association between pain and gray scale (GS) synovitis, odds ratio (OR) = 0.9 (0.6-1.2), p = 0.485; and pain and intra-articular PD, OR = 0.8 (0.6-1.2), p = 0.244. Intra-articular PD was not correlated with pain symptom in this study.

  4. Role of Duplex Power Doppler Ultrasound in Differentiation between Malignant and Benign Thyroid Nodules

    International Nuclear Information System (INIS)

    Algin, Oktay; Algin, Efnan; Gokalp, Gokhan; Ocakog, Gokhan; Erdog an, Cuneyt; Saraydaroglu, Ozlem; Ercan Tuncel, Prof

    2010-01-01

    To evaluate the usage of duplex power Doppler ultrasound (PDUS) for the differentiation of benign and malignant thyroid nodules. We prospectively examined 77 thyroid nodules in 60 patients undergoing ultrasound-guided fine needle aspiration biopsy (FNAB). Each nodule was described according to size, inner structure, borders, parenchymal echogenicity, peripheral halo formation, and the presence of calcification (Bmode ultrasound findings). Vascularity as determined by PDUS imaging was defined as non-vascular, peripheral, central, or of mixed type. For each nodule, the pulsatility index (PI) and resistive index (RI) values were obtained. Results of FNAB and surgical pathological examination (if available) were used as a proof of final diagnosis to categorize all nodules as benign or malignant. A receiver operating characteristic (ROC) curve analysis was performed to establish cut-off, sensitivity, and specificity values associated with RI-PI values. A significant relationship was observed between malignancy and irregular margins, microcalcifications, and hypoechogenicity on ultrasound examination (p 0.05). The central, peripheral, and mean RI-PI values were higher in malignant nodules when compared to the other cytologies (p < 0.05). Vascularity is not a useful parameter for distinguishing malignant from benign thyroid nodules. However, RI and PI values are useful in distinguishing malignant from benign thyroid nodules

  5. Childhood acute pyelonephritis: comparison of power Doppler sonography and Tc-DMSA scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Stogianni, Aggeliki; Oikonomou, Ippoliti; Dimitriadis, Athanasios [Aristotle University of Thessaloniki, Department of Radiology, AHEPA Hospital, Thessaloniki (Greece); Nikolopoulos, Panagiotis [424 Army Hospital, Department of Radiology, Thessaloniki (Greece); Gatzola, Magdalini [Aristotle University of Thessaloniki, 2nd Paediatric Clinic, AHEPA Hospital, Thessaloniki (Greece); Balaris, Vassilios [Aristotle University of Thessaloniki, Department of Nuclear Medicine, AHEPA Hospital, Thessaloniki (Greece); Farmakiotis, Dimitrios [Infectious Diseases Hospital of Thessaloniki, Department of Medicine, Thessaloniki (Greece)

    2007-07-15

    Tc 99m DMSA scintigraphy is regarded as the gold standard for the detection and localization of acute pyelonephritis (APN) in children. Power Doppler sonography (PD US) is a radiation-free and cost-effective technique that could be useful in the diagnosis of APN in children. To compare the predictive value of PD US with DMSA scintigraphy in the diagnosis of APN in children. A total of 74 neonates and children with clinical findings consistent with possible upper urinary tract infection were evaluated with PD US and DMSA scintigraphy. Children with anatomic (grey-scale) abnormalities were excluded. A total of 147 kidneys were examined within the first 48 h after the onset of symptoms. Each kidney was divided into three zones (upper, middle, and lower third). APN was diagnosed by PD US in 46 kidneys. Sensitivity and specificity for detecting APN using DMSA scintigraphy as the reference standard were 73.8% and 85.7%, respectively. There was good agreement between PD US and DMSA scintigraphy in the localization of lesions. In clinically suspected APN, PD US has acceptable specificity and sensitivity, if performed within the first 48 h and could be helpful in neonates and children under 3 months of age in whom the use of scintigraphy is generally discouraged. (orig.)

  6. Power Doppler Imaging in Acute Renal Vein Occlusion and Recanalization: a Canine Model

    International Nuclear Information System (INIS)

    Yoo, So-Young; Kim, In-One; Kim, Young-Il; Lee, Kyoung Ho; Lee, Min Woo; Youn, Byung Jae; Kim, Woo Sun; Yeon, Kyung Mo

    2008-01-01

    Objective : To evaluate the dynamic changes of the power Doppler (PD) in acute renal vein occlusion and recanalization in a canine model. Materials and Methods : We performed a PD of the kidney during graded renal vein occlusion and recanalization induced by balloon inflation and deflation in nine dogs. The PD images were transferred to a personal computer, and the PD signals were quantified. Result : We observed the temporal change of the PD signal during renal vein occlusion and recanalization, with a decrease in the PD signal during occlusion and an increase during recanalization. The mean PD signal decreased gradually as the renal vein was occluded, and conversely increased gradually with sequential relief of occlusion. The sequential change of the mean value of the PD signal was statistically significant. Conclusion : The PD can detect a change in renal blood flow during acute renal vein occlusion and recanalization in a canine model. The PD may be used as a helpful tool for the early detection of acute renal vein thrombosis and the monitoring of renal perfusion

  7. Superficial inflammatory and primary neoplastic lymphadenopathy: diagnostic accuracy of power-doppler sonography

    International Nuclear Information System (INIS)

    Magarelli, N.; Guglielmi, G.; Savastano, M.; Toro, V.; Sborgia, M.; Fioritoni, G.; Mattei, P.A.; Steinbach, L.; Bonomo, L.

    2004-01-01

    Objective: To evaluate the sensitivity, specificity and diagnostic accuracy of a cut-off of the resistive index of 0.5 for the differentiation between inflammatory and neoplastic primary lymphadenopathies. Subjects and methods: We measured the resistive index of superficial enlarged lymph nodes in a total of 50 patients (29 males and 21 females; age range 12-72 years, mean age 41.6 year) using an ATL 5000 HDI. A resistive index greater than or equal to 0.5 indicated an inflammatory lymph node and a resistive index <0.5 was consistent with neoplastic primary lymphadenopathies. The gold standard was either surgical biopsy or lymph-node reduction seen with ultrasound examination after antibiotic therapy. Results: The sensitivity of the resistive index for distinguishing inflammatory from neoplastic lymphadenopathy was 84.6%, the specificity 100% and the diagnostic accuracy 95.7% (P<0.001, statistically significant). Conclusion: The results of this study indicate that power-Doppler using a resistive index cut-off of 0.5 was a valid technique for distinguising between inflammatory and primary neoplastic lymph nodes in patients with superficial lymphadenopathies

  8. Intrinsic subtypes and tumor grades in breast cancer are associated with distinct 3-D power Doppler sonographic vascular features

    International Nuclear Information System (INIS)

    Chang, Yeun-Chung; Huang, Yao-Sian; Huang, Chiun-Sheng; Chen, Jeon-Hor; Chang, Ruey-Feng

    2014-01-01

    Purpose: This study aimed to investigate the three-dimensional (3-D) power Doppler ultrasonographic (PDUS) vascular features of breast carcinoma according to intrinsic subtypes, nodal stage, and tumor grade. Materials and methods: Total 115 receiving mastectomy breast carcinomas (mean size, 2.5 cm; range, 0.7–6.5 cm), including 102 invasive ductal carcinomas (IDC), 10 ductal carcinomas in situ (DCIS), and 3 invasive lobular carcinomas (ILC) diagnosed after mastectomy, were used in this retrospective study. Sixty IDC had nodal status and histopathologic tumor grades available for analysis. Vascular features, including number of vascular trees (NV), longest path length (LPL), total vessel length (TVL), number of bifurcations (NB), distance metric (DM), inflection count metric (ICM), vessel diameter (VD), and vessel-to-volume ratio (VVR) were extracted using 3-D thinning method. The Mann–Whitney U test, Student's t-test, one-way ANOVA, and Kruskal–Wallis test were performed as appropriate. Results: There was no significant difference of vascular features among IDC, DCIS and ILC. Except VD, vascular features in luminal type were significantly lower compared to HER2-enriched or triple negative types (p < 0.05). Compared to ER+ (estrogen receptor positive) tumors, all features in ER− (estrogen receptor negative) tumors were significantly higher (p < 0.01). Despite some significantly higher vascular features in high grade IDC compared to low and intermediate grade, there was no significant correlation between vascular features and nodal stages. Conclusion: Differences in 3-D PDUS vascular features among intrinsic types of IDC are attributed to their ER status. Vascular features extracted by 3-D PDUS correlate with tumor grades but not nodal stage in IDC

  9. Intrinsic subtypes and tumor grades in breast cancer are associated with distinct 3-D power Doppler sonographic vascular features

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Yeun-Chung [Department of Medical Imaging, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei 10041, Taiwan, ROC (China); Huang, Yao-Sian [Department of Computer Science and Information Engineering, National Taiwan University, Taipei 10617, Taiwan, ROC (China); Huang, Chiun-Sheng [Department of Surgery, National Taiwan University Hospital and National Taiwan University College of Medicine, Taipei 10041, Taiwan, ROC (China); Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 10617, Taiwan, ROC (China); Chen, Jeon-Hor [Center for Functional Onco-Imaging and Department of Radiological Science, University of California Irvine, California, CA 92868 (United States); Department of Radiology, E-Da Hospital and I-Shou University, Kaohsiung 82445, Taiwan, ROC (China); Chang, Ruey-Feng, E-mail: rfchang@csie.ntu.edu.tw [Department of Computer Science and Information Engineering, National Taiwan University, Taipei 10617, Taiwan, ROC (China); Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei 10617, Taiwan, ROC (China)

    2014-08-15

    Purpose: This study aimed to investigate the three-dimensional (3-D) power Doppler ultrasonographic (PDUS) vascular features of breast carcinoma according to intrinsic subtypes, nodal stage, and tumor grade. Materials and methods: Total 115 receiving mastectomy breast carcinomas (mean size, 2.5 cm; range, 0.7–6.5 cm), including 102 invasive ductal carcinomas (IDC), 10 ductal carcinomas in situ (DCIS), and 3 invasive lobular carcinomas (ILC) diagnosed after mastectomy, were used in this retrospective study. Sixty IDC had nodal status and histopathologic tumor grades available for analysis. Vascular features, including number of vascular trees (NV), longest path length (LPL), total vessel length (TVL), number of bifurcations (NB), distance metric (DM), inflection count metric (ICM), vessel diameter (VD), and vessel-to-volume ratio (VVR) were extracted using 3-D thinning method. The Mann–Whitney U test, Student's t-test, one-way ANOVA, and Kruskal–Wallis test were performed as appropriate. Results: There was no significant difference of vascular features among IDC, DCIS and ILC. Except VD, vascular features in luminal type were significantly lower compared to HER2-enriched or triple negative types (p < 0.05). Compared to ER+ (estrogen receptor positive) tumors, all features in ER− (estrogen receptor negative) tumors were significantly higher (p < 0.01). Despite some significantly higher vascular features in high grade IDC compared to low and intermediate grade, there was no significant correlation between vascular features and nodal stages. Conclusion: Differences in 3-D PDUS vascular features among intrinsic types of IDC are attributed to their ER status. Vascular features extracted by 3-D PDUS correlate with tumor grades but not nodal stage in IDC.

  10. Neovascularity in patellar tendinopathy and the response to eccentric training: a case report using Power Doppler ultrasound.

    Science.gov (United States)

    McCreesh, Karen M; Riley, Sara J; Crotty, James M

    2013-12-01

    This report describes the case of an amateur soccer player with chronic patellar tendinopathy who underwent ultrasound imaging before and after engaging in an 8-week programme of eccentric exercise. On initial assessment, greyscale ultrasound imaging demonstrated tendon thickening and reduced echogenicity, while Power Doppler imaging demonstrated a large amount of neovascularity. After 8 weeks of an eccentric loading programme, the patient reported significantly improved symptoms and functional scores, while follow-up imaging demonstrated improvement in the echo appearance of the tendon and complete resolution of the neovascularity. The association between neovascularity and symptoms in tendinopathy research is conflicting, with a paucity of research in the area of patellar tendinopathy. While further research is needed to clarify the significance of greyscale and Power Doppler ultrasound changes in relation to symptoms in patellar tendinopathy, ultrasound imaging was shown to be a useful adjunct to diagnosis and outcome assessment in this case. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Power Doppler ultrasonography for assessment of synovitis in the metacarpophalangeal joints of patients with rheumatoid arthritis: a comparison with dynamic magnetic resonance imaging

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, M; Strandberg, C

    2001-01-01

    OBJECTIVE: To evaluate the effectiveness of power Doppler ultrasonography (PDUS) for assessing inflammatory activity in the metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA), using dynamic magnetic resonance imaging (MRI) as a reference method. METHODS: PDUS and dynamic ...

  12. 3D Power Doppler ultrasound and computerised placental assessment in normal pregnancy

    International Nuclear Information System (INIS)

    Moran, Mary; Zombori, Gergely; Ryan, John; McAuliffe, Fionnuala M.

    2014-01-01

    Background: In recent years there have been significant developments in the use of 3D Power Doppler (3DPD) imaging and quantitative 3DPD histogram analysis to estimate both placental volume and intra-placental vasculature. This study aims to determine if placental volume, vascularisation and blood flow are correlated with gestational age in normal pregnancy. It also examines whether or not a new software method for analysis of percentage calcification (the ‘placentometer’) correlates well with gestation. Material and method: This was a prospective cohort study of 250 women with normal pregnancies (12 + 6 to 39 + 5 weeks gestation). 3DPD ultrasound was used to evaluate placental volume, vascularisation index (VI), flow index (FI) and vascularisation-flow index (VFI). Placental volume (calculated at 35–40 weeks gestation), was correlated with birth weight. Following each scan the percentage of calcification was also calculated using the placentometer. Results: Placental volume correlated significantly with gestational age: 66.676 + 0.623 × GA (P < 0.001). No significant change with gestation was noted in VI, FI and VFI (VI: P = 0.199, FI: P = 0.299, VFI: P = 0.557). Software analysis of the percentage of calcification, demonstrated the expected increase in calcification as gestation increased: −4.605 + 0.032 × GA (P < 0.001). From 35 to 40 weeks gestation volume was related to birth weight (P < 0.01). Conclusion: This study shows that in normal low-risk pregnancy placental volume increases with gestational age, whereas vascularisation and blood flow are independent of gestation. Placental volume in late pregnancy is related to birth weight. Software analysis of the percentage of calcification demonstrates an increase with advancing gestation

  13. Acute pyelonephritis in pediatric age: comparative study between power Doppler ultrasound scan and DMSA

    International Nuclear Information System (INIS)

    Muro, M. D.; Sanguesa, C.; Otero, M. C.; Piqueras, A. I.; Lloret, M. T.

    2002-01-01

    To evaluate the usefulness of power Doppler (PD) Ultrasound Scan in the study of acute pyelonephritis (APN). To compare ultrasound scan results with those obtained with renal gammagraphy (DMSA). To relate the findings to the clinical criteria and to determine the presence of vesicoureteral reflux (VUR) in the serial micturition cystography (SMC). Prospective study of 92 patients (ages between 1 month and 10 years) with suspected clinical PNA. All children were initially subjected to PD ultrasound scan and DMSA. Those under 3 years old were also subjected to SMC for the study of VUR. PNA in the PD ultrasound scan was manifested by decrease in vascularisation and in the DMSA by decrease in caption in the affected zones. 87 renal units (RU) with PNA foci were detected. Conformity between the PD ultrasound scan and DMSA was 157 RU (92%): 52 positives, 22 negatives with PNA and 83 normal RU. The sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 80% and 85%, respectively. Mode B ultrasound scan and PD can replace DMSA in the initial study of PPNA. It is non-invasive, simple, economical and just as reliable as DMSA in expert hands. it can also postpone by up to 6 months the need to perform DMSA for detection of permanent renal damage. (Author) 22 refs

  14. Role of 3D power Doppler ultrasound in the further characterization of suspicious breast masses.

    Science.gov (United States)

    Kupeli, Ali; Kul, Sibel; Eyuboglu, Ilker; Oguz, Sukru; Mungan, Sevdegul

    2016-01-01

    To investigate effectiveness of vascular indices obtained with 3D power Doppler ultrasound in the further characterization of breast masses and prevention of unnecessary biopsies. Between April 2013 and March 2014, 109 patients (age range, 17-85 years; mean age, 47 years) with 117 radiologically or clinically suspicious breast masses were prospectively evaluated with 3DPDUS before biopsy. Mass volume (MV), vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were calculated using Virtual Organ Computer-aided Analysis (VOCAL) software and they were correlated with the final diagnosis. Cutoff values of vascular indices were determinated and diagnostic efficacy was calculated with receiver operating curve (ROC) analysis. All vascular indices, age of patients and tumor volume were significantly lower in benign masses compared with malignant ones (p<0.001). AUCs were 0.872, 0.867 and 0.789 for VI, VFI and FI, respectively. The diagnostic efficacy of VI (for cutoff 1.1; 83% sensitivity, 82% specificity and 82% accuracy) and VFI (for cutoff 0.4; 80% sensitivity, 83% specificity and 80% accuracy) were significantly higher than FI (for cutoff 33,9; 73% sensitivity, 69% specificity and 71% accuracy). It was found that with the use of vascular indices of 3DPDUS in the further characterization of suspicious breast masses between 24% to 37% of unnecessary biopsies could have been avoided. The vascular indices obtained with 3DPDUS seem reliable in the further characterization of suspicious breast masses and might be used to decrease unnecessary biopsies. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. Ultrasound guided core biopsy of suspicious mammographic calcifications using high frequency and power Doppler ultrasound

    International Nuclear Information System (INIS)

    Teh, W.L.; Wilson, A.R.M; Evans, A.J.; Burrell, H.; Pinder, S.E.; Ellis, I.O.

    2000-01-01

    AIM: The pre-operative diagnosis of suspicious mammographic microcalcifications usually requires stereotactic needle biopsy. The aim of this study was to evaluate if high frequency 13 MHz ultrasound (HFUS) and power Doppler (PD) can aid visualization and biopsy of microcalcifications. MATERIALS AND METHODS: Forty-four consecutive patients presenting with microcalcifications without associated mammographic or palpable masses were examined with HFUS and PD. Ultrasound-guided core biopsy (USCB) was performed where possible. Stereotactic biopsy was carried out when US-guided biopsy was unsuccessful. Surgery was performed if a diagnosis of malignancy was made on core biopsy or if the repeat core biopsy was non-diagnostic. RESULTS: Forty-one patients (93%) had ultrasound abnormalities corresponding to mammographic calcification. USCB was performed on 37 patients. In 29/37, USCB obtained a definitive result (78.4%). USCB was non-diagnostic in 4/9 benign (44.4%) and 4/28 (14.3%) malignant lesions biopsied. The complete and absolute sensitivities for malignancy using USCB were 85.7% (24/28) and 81% (23/28), respectively. USCB correctly identified invasive disease in 12/23 (52.2%) cases. There was no significant difference in the presence of abnormal flow on PD between benign and malignant lesions. However, abnormal PD vascularity was present in 43.5% of invasive cancer and was useful in directing successful biopsy in eight cases. CONCLUSION: The combination of high frequency US with PD is useful in the detection and guidance of successful needle biopsy of microcalcifications particularly where there is an invasive focus within larger areas of DCIS. Teh, W.L. (2000)

  16. Power Doppler ultrasound phenotyping of expanding versus collapsed popliteal lymph nodes in murine inflammatory arthritis.

    Directory of Open Access Journals (Sweden)

    Echoe M Bouta

    Full Text Available Rheumatoid arthritis is a chronic inflammatory disease manifested by episodic flares in affected joints that are challenging to predict and treat. Longitudinal contrast enhanced-MRI (CE-MRI of inflammatory arthritis in tumor necrosis factor-transgenic (TNF-Tg mice has demonstrated that popliteal lymph nodes (PLN increase in volume and contrast enhancement during the pre-arthritic "expanding" phase of the disease, and then suddenly "collapse" during knee flare. Given the potential of this biomarker of arthritic flare, we aimed to develop a more cost-effective means of phenotyping PLN using ultrasound (US imaging. Initially we attempted to recapitulate CE-MRI of PLN with subcutaneous footpad injection of US microbubbles (DEFINITY®. While this approach allowed for phenotyping via quantification of lymphatic sinuses in PLN, which showed a dramatic decrease in collapsed PLN versus expanding or wild-type (WT PLN, electron microscopy demonstrated that DEFINITY® injection also resulted in destruction of the lymphatic vessels afferent to the PLN. In contrast, Power Doppler (PD US is innocuous to and efficiently quantifies blood flow within PLN of WT and TNF-Tg mice. PD-US demonstrated that expanding PLN have a significantly higher normalized PD volume (NPDV versus collapsed PLN (0.553 ± 0.007 vs. 0.008 ± 0.003; p0.030 and lower (<0.016 quartile NPDVs in this cohort of mice, which serve as conservative thresholds to phenotype PLN as expanding and collapsed, respectively. Interestingly, of the 12 PLN phenotyped by the two methods, there was disagreement in 4 cases in which they were determined to be expanding by CE-MRI and collapsed by PD-US. Since the adjacent knee had evidence of synovitis in all 4 cases, we concluded that the PD-US phenotyping was correct, and that this approach is currently the safest and most cost-effective in vivo approach to phenotype murine PLN as a biomarker of arthritic flare.

  17. Is there subclinical enthesitis in early psoriatic arthritis? A clinical comparison with power doppler ultrasound.

    Science.gov (United States)

    Freeston, J E; Coates, L C; Helliwell, P S; Hensor, E M A; Wakefield, R J; Emery, P; Conaghan, P G

    2012-10-01

    Enthesitis is a recognized feature of spondylarthritides (SpA), including psoriatic arthritis (PsA). Previously, ultrasound imaging has highlighted the presence of subclinical enthesitis in established SpA, but there are little data on ultrasound findings in early PsA. The aim of our study was to compare ultrasound and clinical examination (CE) for the detection of entheseal abnormalities in an early PsA cohort. Forty-two patients with new-onset PsA and 10 control subjects underwent CE of entheses for tenderness and swelling, as well as gray-scale (GS) and power Doppler (PD) ultrasound of a standard set of entheses. Bilateral elbow lateral epicondyles, Achilles tendons, and plantar fascia were assessed by both CE and ultrasound, the latter scored using a semiquantitative (SQ) scale. Inferior patellar tendons were assessed by ultrasound alone. A GS SQ score of >1 and/or a PD score of >0 was used to describe significant ultrasound entheseal abnormality. A total of 24 (57.1%) of 42 patients in the PsA group and 0 (0%) of 10 controls had clinical evidence of at least 1 tender enthesis. In the PsA group, for sites assessed by both CE and ultrasound, 4% (7 of 177) of nontender entheses had a GS score >1 and/or a PD score >0 compared to 24% (9 of 37) of tender entheses. CE overestimated activity in 28 (13%) of 214 of entheses. All the nontender ultrasound-abnormal entheses were in the lower extremity. The prevalence of subclinical enthesitis in this early PsA cohort was low. CE may overestimate active enthesitis. The few subclinically inflamed entheses were in the lower extremity, where mechanical stress is likely to be more significant. Copyright © 2012 by the American College of Rheumatology.

  18. Comparison of power Doppler ultrasonographic findings of mesenteric lymphadenopathy between children with and without acute abdominal pain

    International Nuclear Information System (INIS)

    Hwangbo, Seal; Lim, Gye Yeon; Jang, Hye Suk; Choi, Byoung Gil; Lee, Jae Mun

    2002-01-01

    To evaluate power Doppler ultrasonographic findings of the enlarged mesenteric lymph nodes, and to compare between patients with and without acute abdominal pain. Thirty seven children with acute abdominal pain and thirty three asymptomatic children all with the enlarged mesenteric lymph nodes in whom power Doppler ultrasonography was performed were included in this study. The enlarged lymph nodes were evaluated for number, size, shape (ratio of long to short axis diameter: L/S ratio), distribution and hilar vascularity on gray scale ultrasonography while the flow pattern (3 types; nonvascular, hilar, peripheral type) of the vascularity was analyzed with power Doppler ultrasonography. The hilar pattern of vascular flow type was graded into I to III depending upon color signal. The comparison between symptomatic group and asymptomatic control group was analyzed with gray scale ultrasonography and power Doppler ultrasonography. The number of enlarged lymph nodes (n≥10) was greater in the symptomatic group (29/37, 78%) than in the control group (6/33, 18%) (p<0.01). The mean size of the largest lymph node between two groups was different with a statistical significance; the mean long diameter was 12.4 ± 3.1 mm (short diameter 5.8 ± 1.6 mm) in the symptomatic group and 11.2 ± 2.3 mm (4.5 ± 1.3 mm) in the control group (p<0.05). The mean L/S ratio of the largest one was 2.2 ± 0.6 in the symptomatic group and 2.7 ± 0.8 in the control group (p<0.05). Lymph nodes were detected in both right lower quadrant of the abdomen and periumblical region in 16 (43%) of the symptomatic group and 3 (9%) of the control group (p<0.01). On power Doppler ultrasonography, hilar type of vascularity was noted in 22 (67%) cases of the control group and all of symptomatic group. The prevalence of exuberant hilar flows (grade II/III) in the symptomatic group (28/37, 76%) was significantly higher than that of the control group (4/33,12%) (p<0.01). Enlarged mesenteric lymph nodes in the

  19. Power Doppler Ultrasonography and Shear Wave Elastography as Complementary Imaging Methods for Suspected Local Breast Cancer Recurrence.

    Science.gov (United States)

    Jales, Rodrigo Menezes; Dória, Maira Teixeira; Serra, Kátia Piton; Miranda, Mila Meneguelli; Menossi, Carlos Alberto; Schumacher, Klaus; Sarian, Luis Otávio

    2018-06-01

    To prospectively investigate the diagnostic accuracy and clinical consequences of power Doppler morphologic criteria and shear wave elastography (SWE) as complementary imaging methods for evaluation of suspected local breast cancer recurrence in the ipsilateral breast or chest wall. Thirty-two breast masses with a suspicion of local breast cancer recurrence on B-mode ultrasonography underwent complementary power Doppler and SWE evaluations. Power Doppler morphologic criteria were classified as avascular, hypovascular, or hypervascular. Shear wave elastography was classified according to a 5-point scale (SWE score) and SWE maximum elasticity. Diagnostic accuracy was assessed by the sensitivity, specificity, and area under the curve. A decision curve analysis assessed clinical consequences of each method. The reference standard for diagnosis was defined as core needle or excisional biopsy. Histopathologic examinations revealed 9 (28.2%) benign and 23 (71.8%) malignant cases. Power Doppler ultrasonography (US) had sensitivity of 34.8% (95% confidence interval [CI], 6.6%-62.9%) and specificity of 45.4% (95% CI, 19.3%-71.5%). The SWE score (≥3) had sensitivity of 87.0% (95% CI, 66.4%-97.2%) and specificity of 44.4% (95% CI, 13.7%-78.8%). The SWE maximum elasticity (velocity > 6.5cm/s) had sensitivity of 87% (95% CI, 66.4%-97.2%) and specificity of 77.8% (95% CI, 40.0% to 97.2%). The areas under the curves for the SWE score and SWE maximum elasticity were 0.71 (95% CI, 0.53-0.87) and 0.82 (95% CI, 0.64-0.93), respectively (P = .32). Power Doppler US is unsuitable for discrimination between local breast cancer recurrence and fibrosis. Although the SWE score and SWE maximum elasticity can make this discrimination, the use of these methods to determine biopsy may lead to poorer clinical outcomes than the current practice of performing biopsies of all suspicious masses. © 2017 by the American Institute of Ultrasound in Medicine.

  20. Two-dimensional Doppler echocardiographic correlation of dipyridamole-thallium stress testing with isometric handgrip

    International Nuclear Information System (INIS)

    Whitfield, S.; Aurigemma, G.; Pape, L.; Leppo, J.

    1991-01-01

    To determine how frequently new wall-motion abnormalities that are indicative of ischemia accompany thallium redistribution, 47 consecutive patients underwent two-dimensional, echocardiography during routine dipyridamole-thallium stress testing. A secondary aim of the study was to determine whether the addition of isometric handgrip exercises to the standard dipyridamole imaging protocol increased the frequency of wall-motion abnormalities or thallium redistribution. Echocardiograms and thallium scans were independently interpreted, and wall-motion abnormalities that appeared with dipyridamole, handgrip exercise, or both were compared with results of thallium imaging. Five of 24 patients with thallium redistribution had new wall-motion abnormalities, and the extent (number of segments) of thallium redistribution in these five patients was significantly greater than in those who did not have well-motion abnormalities (p less than 0.03). The addition of isometric handgrip exercises to the imaging protocol did not distinguish between patients with and without new wall-motion abnormalities or thallium redistribution. Thus new wall-motion abnormalities infrequently accompany thallium redistribution in routine dipyridamole stress testing in spite of the addition of handgrip exercises, but when new wall-motion abnormalities are present, they are associated with a greater area of thallium redistribution

  1. Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

    Science.gov (United States)

    Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.; hide

    2001-01-01

    Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

  2. Evaluation of combined intracoronary two-dimensional and doppler ultransound techniques in the relaxation function of coronary microcirculation

    International Nuclear Information System (INIS)

    Qi Chunmei; Li Dongye; Pan Defeng; Zhu Hong

    2005-01-01

    Objective: To observe the value of detecting the relaxation function of coronary microcirculation by using combined intracoronary two-dimensional (IVUS) and Doppler interventional ultransound (ICD) techniques with mean arteries pressure. Methods: Fourteen healthy male swines were divided into two groups randomly: eight swines fed with 1% cholesterol-rich diet for 12 weeks as a model of early atherosclerosis were classified as the experimental group; six swines fed with standard diet were classified as control group. All the swines were undergone cardiovascular catheterization examination after 12 weeks. Combined IVUS and ICD techniques were taken to calculate the change of coronary blood flow (CBF) after the administration of acetylcholine and nitroglycerin. The pressure of the root of aorta and then the relaxation function of coronary microcirculation can be accessed with coronary resistance index (RI). At last, all of the examed coronary arteries and related coronary microcirculation were undergone pathological examinations. Results: The pathological examinations demonstrated that the average intima thickness in experimental group was increased more evidently than that of control group (74.80 μm ± 17.60 μm vs 7.60 μm ± 4.27 μm P<0.001). The intima thickness increase can not be seen in the coronary microcirculation. Acetylcholine induced increase in RI in experimental group compared with control group (-0.18 ± 0.09 vs 0.29 ± 0.18, P<0.05). Nitroglycerin induced a decrease in RI for both groups (-0.40 ± 0.13 vs -0.34 ± 0.20). Conclusions: Using IVUS and ICD techniques combined mean arterial pressure can identify the endothelium-mediated dysfunction on coronary microcirculation in the early stage of AS. (authors)

  3. Images of gravitational and magnetic phenomena derived from two-dimensional back-projection Doppler tomography of interacting binary stars

    International Nuclear Information System (INIS)

    Richards, Mercedes T.; Cocking, Alexander S.; Fisher, John G.; Conover, Marshall J.

    2014-01-01

    We have used two-dimensional back-projection Doppler tomography as a tool to examine the influence of gravitational and magnetic phenomena in interacting binaries that undergo mass transfer from a magnetically active star onto a non-magnetic main-sequence star. This multitiered study of over 1300 time-resolved spectra of 13 Algol binaries involved calculations of the predicted dynamical behavior of the gravitational flow and the dynamics at the impact site, analysis of the velocity images constructed from tomography, and the influence on the tomograms of orbital inclination, systemic velocity, orbital coverage, and shadowing. The Hα tomograms revealed eight sources: chromospheric emission, a gas stream along the gravitational trajectory, a star-stream impact region, a bulge of absorption or emission around the mass-gaining star, a Keplerian accretion disk, an absorption zone associated with hotter gas, a disk-stream impact region, and a hot spot where the stream strikes the edge of a disk. We described several methods used to extract the physical properties of the emission sources directly from the velocity images, including S-wave analysis, the creation of simulated velocity tomograms from hydrodynamic simulations, and the use of synthetic spectra with tomography to sequentially extract the separate sources of emission from the velocity image. In summary, the tomography images have revealed results that cannot be explained solely by gravitational effects: chromospheric emission moving with the mass-losing star, a gas stream deflected from the gravitational trajectory, and alternating behavior between stream state and disk state. Our results demonstrate that magnetic effects cannot be ignored in these interacting binaries.

  4. Achilles tendon (TA) size and power Doppler ultrasound (PD) changes compared to MRI: A preliminary observational study

    International Nuclear Information System (INIS)

    Richards, P.J.; Dheer, A.K.; McCall, I.M.

    2001-01-01

    AIM: To assess whether abnormal Achilles tendon (TA) magnetic resonance imaging (MRI) and spectral ultrasound (US) features have associated development of microvascular power Doppler (PD) flow. MATERIALS AND METHODS: In a prospective, controlled and blinded study six patients with TA symptoms were compared to five with other ankle abnormalities. Two radiologists independently measured the mean maximal anteroposterior diameter on MRI and conventional US (categorized as normal 1.6 cm), assessed morphology and studied the vessels using power Doppler. They formed a consensus over discrepancies. Sonography of the contralateral side within 24 h was used as a control. RESULTS: Twenty-one tendons in six women and five men, aged 45-77 years (mean 57.6 years), were examined, 12 tendons were of normal US morphology and size ( 0.74). Of the 12 tendons studied by MRI five were normal, seven tendons were enlarged, five of which had a proportionate increase in PD flow at the margin on the deep surface and four also had vessels in the centre of the tendon. All five of these tendons had high signal on T2-weighting (T2W). Of the two mildly enlarged tendons of intermediate signal on T1 and T2W, one showed PD flow and the other did not. CONCLUSIONS: In patients with TA disease power Doppler ultrasound shows proliferation of vessels in enlarged, abnormal tendons demonstrated on MRI and standard ultrasound, in the absence of definite tears. Richards, P.J. Dheer, A.K. and McCall, I.M. (2001)

  5. Contrast-enhanced Harmonic power Doppler ultrasonography: Improved depiction of vascularity and characterization of flow pattern in hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Baek, Hyung Chul; Yoon, Kwon Ha; Kim, Chang Guhn; Park, Ki Han; Won, Jong Jin

    2000-01-01

    To evaluate the value of contrast-enhanced harmonic power Doppler ultrasonography (PDUS) in depiction and characterization of tumoral vascularity in hepatocellular carcinoma (HCC). Thirty-three patients with HCC were prospectively evaluated with harmonic PDUS before and after injection of the contrast agent SH U 508A (2.5g, 300 mg/ml ). Unenhanced and serial dynamic scans at 15, 30, 45, 60, 90, 120, 150, 180, 240, 300 seconds after injection of contrast agents were obtained using a tissue harmonic technique with power Doppler imaging. The tumoral vascularity was expressed as percentage of power Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The grade (0, no signal; 1, less than 5%; 2, 5-25%; 3, more than 25%) and flow pattern (intratumoral, detour, basket, and mixed) of tumoral vascularity were analyzed. Peak time of contrast-enhancement was measured on each tumor. After injection of contrast agent, tumoral flow signals increased in all lesions (100%). At unenhanced harmonic PDUS, flow signals were detected in 17 HCCs (52%); 15 tumors (46%) demonstrated grade 1 vascularity; and two (6%), grade 2. At contrast-enhanced harmonic PDUS, all tumors were detected vascularity; five (15%) were grade 1; eight (24%), grade 2; and 20 (61%), grade 3. Flow patterns were demonstated as follows at unenhanced harmonic PDUS; intratumoral pattern in 13 tumors (76%), detour in 2 (12%), and basket in 2 (12%). After injection of contrast agent, intratumoral pattern in 7 tumors (21%), detour 0 (0%), basket in 3 (9%) and mixed in 23 (70%) were demonstrated. Peak time of enhancement after injection of contrast agent was 30- 90 seconds in majority of the patients. Contrast-enhanced harmonic PDUS would be valuable in depiction of vascularity and characterization of flow pattern in HCC.

  6. Contrast-enhanced Harmonic power Doppler ultrasonography: Improved depiction of vascularity and characterization of flow pattern in hepatocellular carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Hyung Chul; Yoon, Kwon Ha; Kim, Chang Guhn; Park, Ki Han; Won, Jong Jin [Wonkwang University School of Medicine, Iksa (Korea, Republic of)

    2000-12-15

    To evaluate the value of contrast-enhanced harmonic power Doppler ultrasonography (PDUS) in depiction and characterization of tumoral vascularity in hepatocellular carcinoma (HCC). Thirty-three patients with HCC were prospectively evaluated with harmonic PDUS before and after injection of the contrast agent SH U 508A (2.5g, 300 mg/ml ). Unenhanced and serial dynamic scans at 15, 30, 45, 60, 90, 120, 150, 180, 240, 300 seconds after injection of contrast agents were obtained using a tissue harmonic technique with power Doppler imaging. The tumoral vascularity was expressed as percentage of power Doppler area, which was measured quantitatively by a computerized program (Ultrasonic Imaging Tool; Soongsil University, Seoul, Korea). The grade (0, no signal; 1, less than 5%; 2, 5-25%; 3, more than 25%) and flow pattern (intratumoral, detour, basket, and mixed) of tumoral vascularity were analyzed. Peak time of contrast-enhancement was measured on each tumor. After injection of contrast agent, tumoral flow signals increased in all lesions (100%). At unenhanced harmonic PDUS, flow signals were detected in 17 HCCs (52%); 15 tumors (46%) demonstrated grade 1 vascularity; and two (6%), grade 2. At contrast-enhanced harmonic PDUS, all tumors were detected vascularity; five (15%) were grade 1; eight (24%), grade 2; and 20 (61%), grade 3. Flow patterns were demonstated as follows at unenhanced harmonic PDUS; intratumoral pattern in 13 tumors (76%), detour in 2 (12%), and basket in 2 (12%). After injection of contrast agent, intratumoral pattern in 7 tumors (21%), detour 0 (0%), basket in 3 (9%) and mixed in 23 (70%) were demonstrated. Peak time of enhancement after injection of contrast agent was 30- 90 seconds in majority of the patients. Contrast-enhanced harmonic PDUS would be valuable in depiction of vascularity and characterization of flow pattern in HCC.

  7. Analysis of chaos in high-dimensional wind power system.

    Science.gov (United States)

    Wang, Cong; Zhang, Hongli; Fan, Wenhui; Ma, Ping

    2018-01-01

    A comprehensive analysis on the chaos of a high-dimensional wind power system is performed in this study. A high-dimensional wind power system is more complex than most power systems. An 11-dimensional wind power system proposed by Huang, which has not been analyzed in previous studies, is investigated. When the systems are affected by external disturbances including single parameter and periodic disturbance, or its parameters changed, chaotic dynamics of the wind power system is analyzed and chaotic parameters ranges are obtained. Chaos existence is confirmed by calculation and analysis of all state variables' Lyapunov exponents and the state variable sequence diagram. Theoretical analysis and numerical simulations show that the wind power system chaos will occur when parameter variations and external disturbances change to a certain degree.

  8. Hepatic hemangiomas: spectrum of US appearances on gray-scale, power doppler, and contrast-enhanced US

    International Nuclear Information System (INIS)

    Kim, Kyoung Won; Kim, Tae Kyoung; Han Joon Koo; Kim, Ah Young; Lee, Hyun Ju; Park, Seong Ho; Kim, Young Hoon; Choi, Byung Ihn

    2000-01-01

    Because US plays a key role in the initial evaluation of hepatic hemangiomas, knowledge of the entire spectrum of US appearances of these tumors is important. Most hemangiomas have a distinctive US appearance, and even with those with atypical appearances on conventional gray-scale US, specific diagnoses can be made using pulse-inversion harmonic US with contrast agents. In this essay, we review the spectrum of US appearances of hepatic hemangiomas on conventional gray-scale, power Doppler, and pulse-inversion harmonic US with contrast agents. (author)

  9. Reconstruction of Typhoon Structure Using 3-Dimensional Doppler Radar Radial Velocity Data with the Multigrid Analysis: A Case Study in an Idealized Simulation Context

    Directory of Open Access Journals (Sweden)

    Hongli Fu

    2016-01-01

    Full Text Available Extracting multiple-scale observational information is critical for accurately reconstructing the structure of mesoscale circulation systems such as typhoon. The Space and Time Mesoscale Analysis System (STMAS with multigrid data assimilation developed in Earth System Research Laboratory (ESRL in National Oceanic and Atmospheric Administration (NOAA has addressed this issue. Previous studies have shown the capability of STMAS to retrieve multiscale information in 2-dimensional Doppler radar radial velocity observations. This study explores the application of 3-dimensional (3D Doppler radar radial velocities with STMAS for reconstructing a 3D typhoon structure. As for the first step, here, we use an idealized simulation framework. A two-scale simulated “typhoon” field is constructed and referred to as “truth,” from which randomly distributed conventional wind data and 3D Doppler radar radial wind data are generated. These data are used to reconstruct the synthetic 3D “typhoon” structure by the STMAS and the traditional 3D variational (3D-Var analysis. The degree by which the “truth” 3D typhoon structure is recovered is an assessment of the impact of the data type or analysis scheme being evaluated. We also examine the effects of weak constraint and strong constraint on STMAS analyses. Results show that while the STMAS is superior to the traditional 3D-Var for reconstructing the 3D typhoon structure, the strong constraint STMAS can produce better analyses on both horizontal and vertical velocities.

  10. The utility of ultrasound superb microvascular imaging for evaluation of breast tumour vascularity: comparison with colour and power Doppler imaging regarding diagnostic performance.

    Science.gov (United States)

    Park, A Y; Seo, B K; Woo, O H; Jung, K S; Cho, K R; Park, E K; Cha, S H; Cha, J

    2018-03-01

    To investigate the utility of superb microvascular imaging (SMI) for evaluating the vascularity of breast masses in comparison with colour or power Doppler ultrasound (US) and the effect on diagnostic performance. A total of 191 biopsy-proven masses (99 benign and 92 malignant) in 166 women with greyscale, colour Doppler, power Doppler, and SMI images were enrolled in this retrospective study. Three radiologists analysed the vascular images using a three-factor scoring system to evaluate the number, morphology, and distribution of tumour vessels. They assessed the Breast Imaging-Reporting and Data System categories for greyscale US alone and combinations of greyscale US and each type of vascular US. The Kruskal-Wallis test was performed and the area under the receiver-operating characteristic curve (AUC) measured. On SMI, vascular scores were compared between benign and malignant masses and the optimal cut-off value for the overall score was determined. SMI showed higher vascular scores than colour or power Doppler US and malignant masses had higher scores than benign masses (ppower Doppler US (AUC, 0.815 versus 0.774, 0.789, 0.791; ppower Doppler US for characterising the vascularity in breast masses and improving diagnostic performance. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Ultrasound propagation in steel piping at electric power plant using clamp-on ultrasonic pulse doppler velocity-profile flowmeter

    International Nuclear Information System (INIS)

    Tezuka, Kenichi; Mori, Michitsugu; Wada, Sanehiro; Aritomi, Masanori; Kikura, Hiroshige

    2008-01-01

    Venturi nozzles are widely used to measure the flow rates of reactor feedwater. This flow rate of nuclear reactor feedwater is an important factor in the operation of nuclear power reactors. Some other types of flowmeters have been proposed to improve measurement accuracy. The ultrasonic pulse Doppler velocity-profile flowmeter is expected to be a candidate method because it can measure the flow profiles across the pipe cross sections. For the accurate estimation of the flow velocity, the incidence angle of ultrasonic entering the fluid should be carefully estimated by the theoretical approach. However, the evaluation of the ultrasound propagation is not straightforward for the several reasons such as temperature gradient in the wedge or mode conversion at the interface between the wedge and pipe. In recent years, the simulation code for ultrasound propagation has come into use in the nuclear field for nondestructive testing. This article analyzes and discusses ultrasound propagation in steel piping and water, using the 3D-FEM simulation code and the Kirchhoff method, as it relates to the flow profile measurements in power plants with the ultrasonic pulse Doppler velocity-profile flowmeter. (author)

  12. Quantitative power Doppler ultrasound measures of peripheral joint synovitis in poor prognosis early rheumatoid arthritis predict radiographic progression.

    Science.gov (United States)

    Sreerangaiah, Dee; Grayer, Michael; Fisher, Benjamin A; Ho, Meilien; Abraham, Sonya; Taylor, Peter C

    2016-01-01

    To assess the value of quantitative vascular imaging by power Doppler US (PDUS) as a tool that can be used to stratify patient risk of joint damage in early seropositive RA while still biologic naive but on synthetic DMARD treatment. Eighty-five patients with seropositive RA of power Doppler volume and 2D vascularity scores were the most useful US predictors of deterioration. These variables were modelled in two equations that estimate structural damage over 12 months. The equations had a sensitivity of 63.2% and specificity of 80.9% for predicting radiographic structural damage and a sensitivity of 54.2% and specificity of 96.7% for predicting structural damage on ultrasonography. In seropositive early RA, quantitative vascular imaging by PDUS has clinical utility in predicting which patients will derive benefit from early use of biologic therapy. © The Author 2015. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Three-dimensional imaging of absolute blood flow velocity and blood vessel position under low blood flow velocity based on Doppler signal information included in scattered light from red blood cells

    Science.gov (United States)

    Kyoden, Tomoaki; Akiguchi, Shunsuke; Tajiri, Tomoki; Andoh, Tsugunobu; Hachiga, Tadashi

    2017-11-01

    The development of a system for in vivo visualization of occluded distal blood vessels for diabetic patients is the main target of our research. We herein describe two-beam multipoint laser Doppler velocimetry (MLDV), which measures the instantaneous multipoint flow velocity and can be used to observe the blood flow velocity in peripheral blood vessels. By including a motorized stage to shift the measurement points horizontally and in the depth direction while measuring the velocity, the path of the blood vessel in the skin could be observed using blood flow velocity in three-dimensional space. The relationship of the signal power density between the blood vessel and the surrounding tissues was shown and helped us identify the position of the blood vessel. Two-beam MLDV can be used to simultaneously determine the absolute blood flow velocity distribution and identify the blood vessel position in skin.

  14. The prediction of radiofrequency ablation zone volume using vascular indices of 3-dimensional volumetric colour Doppler ultrasound in an in vitro blood-perfused bovine liver model

    Science.gov (United States)

    Lanctot, Anthony C; McCarter, Martin D; Roberts, Katherine M; Glueck, Deborah H; Dodd, Gerald D

    2017-01-01

    Objective: To determine the most reliable predictor of radiofrequency (RF) ablation zone volume among three-dimensional (3D) volumetric colour Doppler vascular indices in an in vitro blood-perfused bovine liver model. Methods: 3D colour Doppler volume data of the local hepatic parenchyma were acquired from 37 areas of 13 bovine livers connected to an in vitro oxygenated blood perfusion system. Doppler vascular indices of vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were obtained from the volume data using 3D volume analysis software. 37 RF ablations were performed at the same locations where the ultrasound data were obtained from. The relationship of these vascular indices and the ablation zone volumes measured from gross specimens were analyzed using a general linear mixed model fit with random effect for liver and backward stepwise regression analysis. Results: FI was significantly associated with ablation zone volumes measured on gross specimens (p = 0.0047), but explained little of the variance (Rβ2 = 0.21). Ablation zone volume decreased by 0.23 cm3 (95% confidence interval: −0.38, −0.08) for every 1 increase in FI. Neither VI nor VFI was significantly associated with ablation zone volumes (p > 0.05). Conclusion: Although FI was associated with ablation zone volumes, it could not sufficiently explain their variability, limiting its clinical applicability. VI, FI and VFI are not clinically useful in the prediction of RF ablation zone volume in the liver. Advances in knowledge: Despite a significant association of FI with ablation zone volumes, VI, FI and VFI cannot be used for their prediction. Different Doppler vascular indices need to be investigated for clinical use. PMID:27925468

  15. Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

    Science.gov (United States)

    Shiota, Takahiro; Jones, Michael; Tsujino, Hiroyuki; Qin, Jian Xin; Zetts, Arthur D.; Greenberg, Neil L.; Cardon, Lisa A.; Panza, Julio A.; Thomas, James D.

    2002-01-01

    BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

  16. Three-dimensional testing of power plant components

    International Nuclear Information System (INIS)

    Martin, A.

    1989-01-01

    Industrial photogrammetry is a dimensional checking procedure whose main advantages are the fast acquisition of the basic data (image), contactless inspection, and independent data processing. As a result of these basic characteristics, photogrammetry is particularly well suited to the maintenance of nuclear power plants. Since 1983, Framatome has employed photogrammetry in a number of cases for 3D dimensional checks and inspections of systems for repair purposes. To this day, e.g., the tube plates of steam generators have been inspected, the dimensional stability of the support rings in steam generators have been checked, and the alignment pins of fuel elements have been examined in this way. (orig.) [de

  17. Automated flow quantification in valvular heart disease based on backscattered Doppler power analysis: implementation on matrix-array ultrasound imaging systems.

    Science.gov (United States)

    Buck, Thomas; Hwang, Shawn M; Plicht, Björn; Mucci, Ronald A; Hunold, Peter; Erbel, Raimund; Levine, Robert A

    2008-06-01

    Cardiac ultrasound imaging systems are limited in the noninvasive quantification of valvular regurgitation due to indirect measurements and inaccurate hemodynamic assumptions. We recently demonstrated that the principle of integration of backscattered acoustic Doppler power times velocity can be used for flow quantification in valvular regurgitation directly at the vena contracta of a regurgitant flow jet. We now aimed to accomplish implementation of automated Doppler power flow analysis software on a standard cardiac ultrasound system utilizing novel matrix-array transducer technology with detailed description of system requirements, components and software contributing to the system. This system based on a 3.5 MHz, matrix-array cardiac ultrasound scanner (Sonos 5500, Philips Medical Systems) was validated by means of comprehensive experimental signal generator trials, in vitro flow phantom trials and in vivo testing in 48 patients with mitral regurgitation of different severity and etiology using magnetic resonance imaging (MRI) for reference. All measurements displayed good correlation to the reference values, indicating successful implementation of automated Doppler power flow analysis on a matrix-array ultrasound imaging system. Systematic underestimation of effective regurgitant orifice areas >0.65 cm(2) and volumes >40 ml was found due to currently limited Doppler beam width that could be readily overcome by the use of new generation 2D matrix-array technology. Automated flow quantification in valvular heart disease based on backscattered Doppler power can be fully implemented on board a routinely used matrix-array ultrasound imaging systems. Such automated Doppler power flow analysis of valvular regurgitant flow directly, noninvasively, and user independent overcomes the practical limitations of current techniques.

  18. Quantitative comparison of tumor vascularity of HCC after intravenous contrast Agent: Conventional versus harmonic power Doppler US

    International Nuclear Information System (INIS)

    Park, Seong Ho; Kim, Tae Kyoung; Lee, Kyoung Ho; Kim, Ah Young; Han, Joon Koo; Choi, Byung Ihn

    1999-01-01

    For the quantitative comparison of the degree of enhancement in nodular hepatocellular carcinoma (HCC) at conventional and harmonic Power Doppler (PD) ultrasound (US). The average of %PDA of ten nodules gradually increased until 60 seconds after contrast injection and then gradually decreased. The average %PDA on conventional and harmonic PD US at 60 seconds were 34.9% and 19.5%, respectively. The average %PDA were significantly higher on conventional PD US than those on harmonic PD US at all times except at 20 seconds. The ratio of average %pda on conventional PD US to those on harmonic PD US became gradually larger after 120 seconds. Although contrast-enhanced harmonic PD US can be an effective method in evaluating the tumor vascularity of HCC because of less PD artifacts, the duration of effective enhancement was shorter and degree of enhancement is less than that of conventional PD US.

  19. Automated assessment of joint synovitis activity from medical ultrasound and power doppler examinations using image processing and machine learning methods

    Directory of Open Access Journals (Sweden)

    Rafal Cupek

    2016-11-01

    Full Text Available Objectives : Rheumatoid arthritis is the most common rheumatic disease with arthritis, and causes substantial functional disability in approximately 50% patients after 10 years. Accurate measurement of the disease activity is crucial to provide an adequate treatment and care to the patients. The aim of this study is focused on a computer aided diagnostic system that supports an assessment of synovitis severity. Material and methods : This paper focus on a computer aided diagnostic system that was developed within joint Polish–Norwegian research project related to the automated assessment of the severity of synovitis. Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Synovitis is estimated by ultrasound examiner using the scoring system graded from 0 to 3. Activity score is estimated on the basis of the examiner’s experience or standardized ultrasound atlases. The method needs trained medical personnel and the result can be affected by a human error. Results : The porotype of a computer-aided diagnostic system and algorithms essential for an analysis of ultrasonic images of finger joints are main scientific output of the MEDUSA project. Medusa Evaluation System prototype uses bone, skin, joint and synovitis area detectors for mutual structural model based evaluation of synovitis. Finally, several algorithms that support the semi-automatic or automatic detection of the bone region were prepared as well as a system that uses the statistical data processing approach in order to automatically localize the regions of interest. Conclusions : Semiquantitative ultrasound with power Doppler is a reliable and widely used method of assessing synovitis. Activity score is estimated on the basis of the examiner’s experience and the result can be affected by a human error. In this paper we presented the MEDUSA project which is focused on a computer aided diagnostic system that supports an

  20. Two-dimensional and Doppler echocardiographic findings in healthy non-sedated red-eared slider terrapins (Trachemys scripta elegans).

    Science.gov (United States)

    Poser, H; Russello, G; Zanella, A; Bellini, L; Gelli, D

    2011-12-01

    Echocardiographic evaluation was performed in six healthy young adult non-sedated terrapins (Trachemys scripta elegans). The best imaging quality was obtained through the right cervical window. Base-apex inflow and outflow views were recorded, ventricular size, ventricular wall thickness and ventricular outflow tract were measured, and fractional shortening was calculated. Pulsed-wave Doppler interrogation enabled the diastolic biphasic atrio-ventricular flow and the systolic ventricular outflow patterns to be recorded. The following Doppler-derived functional parameters were calculated: early diastolic (E) and late diastolic (A) wave peak velocities, E/A ratio, ventricular outflow systolic peak and mean velocities and gradients, Velocity-Time Integral, acceleration and deceleration times, and Ejection Time. For each parameter the mean, standard deviation and 95% confidence interval were calculated. Echocardiography resulted as a useful and easy-to-perform diagnostic tool in this poorly known species that presents difficulties during evaluation.

  1. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.

    Science.gov (United States)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F; Winther-Jensen, Matilde; Nilsson, Jens C; Kjaergaard, Jesper; Møller-Sørensen, Hasse

    2018-01-09

    Estimation of cardiac output (CO) is essential in the treatment of circulatory unstable patients. CO measured by pulmonary artery catheter thermodilution is considered the gold standard but carries a small risk of severe complications. Stroke volume and CO can be measured by transesophageal echocardiography (TEE), which is widely used during cardiac surgery. We hypothesized that Doppler-derived CO by 3-dimensional (3D) TEE would agree well with CO measured with pulmonary artery catheter thermodilution as a reference method based on accurate measurements of the cross-sectional area of the left ventricular outflow tract. The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias (mean difference between methods), limits of agreement (equal to bias ± 2 standard deviations of the bias), and percentage error (limits of agreement divided by the mean of the 2 methods). Precision was determined for the individual methods (equal to 2 standard deviations of the bias between replicate measurements) to determine the acceptable limits of agreement. We found a good precision for Doppler-derived CO measured by 3D TEE, but although the bias for Doppler-derived CO by 3D compared to

  2. Joint positions matter for ultrasound examination of RA patients-increased power Doppler signal in neutral versus flat position of hands.

    Science.gov (United States)

    Husic, Rusmir; Lackner, Angelika; Stradner, Martin H; Hermann, Josef; Dejaco, Christian

    2017-08-01

    Position of joints might influence the result of US examination in patients with RA. The purpose of this work was to compare grey-scale (GS) and power Doppler (PWD) findings obtained in neutral vs flat position of hands. A cross-sectional study of 42 RA patients with active disease. Two dimensional and 3D sonography of wrists and MCP joints were conducted in two different joint positions: neutral position, which is a slight flexion of the fingers with relaxed extensor muscles; and flat position, where all palm and volar sides of fingers touch the Table. Two dimensional GS synovitis (GSS) and PWD signals were scored semi-quantitatively (0-3). For 3D sonography, the percentage of PWD voxels within a region of interest was calculated. GSS was not quantified using 3D sonography. Compared with neutral position, 2D PWD signals disappeared in 28.3% of joints upon flattening. The median global 2D PWD score (sum of all PWD scores of an individual patient) decreased from 8 to 3 ( P < 0.001), and the global 3D PWD voxel score from 3.8 to 0.9 ( P < 0.001). The reduction of PWD scores was similar in all joints (2D: minus 50%, 3D: minus 66.4-80.1%). Inter- and intrareader agreement of PWD results was good (intraclass correlation coefficient: 0.75-0.82). In RA, a neutral position of the hands is linked to a higher sensitivity of 2D and 3D sonography in detecting PWD signals at wrists and MCP joints, compared with a flat position. Standardization of the scanning procedure is essential for obtaining comparable US results in RA patients in trials and clinical routines. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  3. Prenatal Diagnosis of Persistent Right Umbilical Vein Using Three-dimensional Sonography with Power Doppler

    Directory of Open Access Journals (Sweden)

    Pei-Yin Yang

    2007-03-01

    Conclusion: PRUV is a common vascular anomaly that is easy to be overlooked. Reconstruction of the portal system in the affected fetuses using 3D ultrasound facilitated the identification of the DV. If the DV is present, and other anomalies are excluded, the fetus with PRUV has a good outcome.

  4. Quantitative analysis of normal fetal brain volume and flow by three-dimensional power Doppler ultrasound

    Directory of Open Access Journals (Sweden)

    Ju-Chun Hsu

    2013-09-01

    Conclusion: 3D ultrasound can be used to assess the fetal brain volume and blood flow development quantitatively. Our study indicates that the fetal brain vascularization and blood flow correlates significantly with the advancement of GA. This information may serve as a reference point for further studies of the fetal brain volume and blood flow in abnormal conditions.

  5. Three-dimensional power Doppler ultrasonography in evaluation of adnexal masses

    Directory of Open Access Journals (Sweden)

    Ahmed M. Abbas

    2017-12-01

    The introduction of 3DPD has opened the possibility to characterize microvasculature of the adnexal masses and objectively assess tumor vascularization. 3DPD allows also an objective measurement of vascularity of a given region of interest by estimating 3 vascular indices (vascularization index [VI], flow index [FI], and vascularization-flow index [VFI] within such region. The aim of this review article is to evaluate the role of 3DPD in the assessment of adnexal masses vascularity, its ability to discriminate benign masses from malignant ones.

  6. Effectiveness of evaluating tumor vascularization using 3D power Doppler ultrasound with high-definition flow technology in the prediction of the response to neoadjuvant chemotherapy for T2 breast cancer: a preliminary report.

    Science.gov (United States)

    Shia, Wei-Chung; Chen, Dar-Ren; Huang, Yu-Len; Wu, Hwa-Koon; Kuo, Shou-Jen

    2015-10-07

    The aim of this study was to evaluate the effectiveness of advanced ultrasound (US) imaging of vascular flow and morphological features in the prediction of a pathologic complete response (pCR) and a partial response (PR) to neoadjuvant chemotherapy for T2 breast cancer.Twenty-nine consecutive patients with T2 breast cancer treated with six courses of anthracycline-based neoadjuvant chemotherapy were enrolled. Three-dimensional (3D) power Doppler US with high-definition flow (HDF) technology was used to investigate the blood flow in and morphological features of the tumors. Six vascularity quantization features, three morphological features, and two vascular direction features were selected and extracted from the US images. A support vector machine was used to evaluate the changes in vascularity after neoadjuvant chemotherapy, and pCR and PR were predicted on the basis of these changes.The most accurate prediction of pCR was achieved after the first chemotherapy cycle, with an accuracy of 93.1% and a specificity of 85.5%, while that of a PR was achieved after the second cycle, with an accuracy of 79.31% and a specificity of 72.22%.Vascularity data can be useful to predict the effects of neoadjuvant chemotherapy. Determination of changes in vascularity after neoadjuvant chemotherapy using 3D power Doppler US with HDF can generate accurate predictions of the patient response, facilitating early decision-making.

  7. Effectiveness of evaluating tumor vascularization using 3D power Doppler ultrasound with high-definition flow technology in the prediction of the response to neoadjuvant chemotherapy for T2 breast cancer: a preliminary report

    International Nuclear Information System (INIS)

    Shia, Wei-Chung; Chen, Dar-Ren; Huang, Yu-Len; Wu, Hwa-Koon; Kuo, Shou-Jen

    2015-01-01

    The aim of this study was to evaluate the effectiveness of advanced ultrasound (US) imaging of vascular flow and morphological features in the prediction of a pathologic complete response (pCR) and a partial response (PR) to neoadjuvant chemotherapy for T2 breast cancer.Twenty-nine consecutive patients with T2 breast cancer treated with six courses of anthracycline-based neoadjuvant chemotherapy were enrolled. Three-dimensional (3D) power Doppler US with high-definition flow (HDF) technology was used to investigate the blood flow in and morphological features of the tumors. Six vascularity quantization features, three morphological features, and two vascular direction features were selected and extracted from the US images. A support vector machine was used to evaluate the changes in vascularity after neoadjuvant chemotherapy, and pCR and PR were predicted on the basis of these changes.The most accurate prediction of pCR was achieved after the first chemotherapy cycle, with an accuracy of 93.1% and a specificity of 85.5%, while that of a PR was achieved after the second cycle, with an accuracy of 79.31% and a specificity of 72.22%.Vascularity data can be useful to predict the effects of neoadjuvant chemotherapy. Determination of changes in vascularity after neoadjuvant chemotherapy using 3D power Doppler US with HDF can generate accurate predictions of the patient response, facilitating early decision-making. (paper)

  8. Effectiveness of evaluating tumor vascularization using 3D power Doppler ultrasound with high-definition flow technology in the prediction of the response to neoadjuvant chemotherapy for T2 breast cancer: a preliminary report

    Science.gov (United States)

    Shia, Wei-Chung; Chen, Dar-Ren; Huang, Yu-Len; Wu, Hwa-Koon; Kuo, Shou-Jen

    2015-10-01

    The aim of this study was to evaluate the effectiveness of advanced ultrasound (US) imaging of vascular flow and morphological features in the prediction of a pathologic complete response (pCR) and a partial response (PR) to neoadjuvant chemotherapy for T2 breast cancer. Twenty-nine consecutive patients with T2 breast cancer treated with six courses of anthracycline-based neoadjuvant chemotherapy were enrolled. Three-dimensional (3D) power Doppler US with high-definition flow (HDF) technology was used to investigate the blood flow in and morphological features of the tumors. Six vascularity quantization features, three morphological features, and two vascular direction features were selected and extracted from the US images. A support vector machine was used to evaluate the changes in vascularity after neoadjuvant chemotherapy, and pCR and PR were predicted on the basis of these changes. The most accurate prediction of pCR was achieved after the first chemotherapy cycle, with an accuracy of 93.1% and a specificity of 85.5%, while that of a PR was achieved after the second cycle, with an accuracy of 79.31% and a specificity of 72.22%. Vascularity data can be useful to predict the effects of neoadjuvant chemotherapy. Determination of changes in vascularity after neoadjuvant chemotherapy using 3D power Doppler US with HDF can generate accurate predictions of the patient response, facilitating early decision-making.

  9. Does ultrasound contrast agent improve the diagnostic value of colour and power Doppler sonography in superficial lymph node enlargement?

    International Nuclear Information System (INIS)

    Schulte-Altedorneburg, Gernot; Demharter, Johannes; Linne, Renate; Droste, Dirk W.; Bohndorf, Klaus; Buecklein, Wolfgang

    2003-01-01

    Objective: to analyse whether ultrasound contrast agent (UCA) improves the diagnostic accuracy to differentiate between benign and malignant superficial lymph node enlargement by using colour-coded duplex sonography (CCDS) and power Doppler (PD). Methods: 32 patients with suspected malignant superficial lymph node enlargement prospectively underwent standardised ultrasound examinations using B-mode sonography and native and contrast-enhanced CCDS and PD immediately before biopsy. Solbiati-Index (longitudinal-transverse diameter ratio) and intranodal flow patterns by using different vascularisation types were assessed. Histological and sonographical findings were correlated. Results: 27 malignant and 5 benign lymph nodes were found. Solbiati-Index was lower in malignant lymph nodes than in benign nodes (mean 1.5 vs. 2.4, P<0.045). More intranodal flow patterns could be detected after UCA (53 vs. 43) but the number of correctly identified malignant nodes decreased after UCA (26 vs. 24) and the number of correctly identified benign nodes remained constant compared with native CCDS and PD. In 31% of the colour-mode studies, PD was considered to visualise more clearly intranodal vascular flow patterns than CCDS. Conclusion: despite depicting more intranodal vascular patterns, the use of an ultrasound contrast agent seems not to improve the diagnostic value of CCDS and PD compared with native colour-mode studies in superficial lymph node enlargement

  10. Detection of vascularity in wrist tenosynovitis: power doppler ultrasound compared with contrast-enhanced grey-scale ultrasound.

    Science.gov (United States)

    Klauser, Andrea S; Franz, Magdalena; Arora, Rohit; Feuchtner, Gudrun M; Gruber, Johann; Schirmer, Michael; Jaschke, Werner R; Gabl, Markus F

    2010-01-01

    We sought to assess vascularity in wrist tenosynovitis by using power Doppler ultrasound (PDUS) and to compare detection of intra- and peritendinous vascularity with that of contrast-enhanced grey-scale ultrasound (CEUS). Twenty-six tendons of 24 patients (nine men, 15 women; mean age ± SD, 54.4 ± 11.8 years) with a clinical diagnosis of tenosynovitis were examined with B-mode ultrasonography, PDUS, and CEUS by using a second-generation contrast agent, SonoVue (Bracco Diagnostics, Milan, Italy) and a low-mechanical-index ultrasound technique. Thickness of synovitis, extent of vascularized pannus, intensity of peritendinous vascularisation, and detection of intratendinous vessels was incorporated in a 3-score grading system (grade 0 to 2). Interobserver variability was calculated. With CEUS, a significantly greater extent of vascularity could be detected than by using PDUS (P < 0.001). In terms of peri- and intratendinous vessels, CEUS was significantly more sensitive in the detection of vascularization compared with PDUS (P < 0.001). No significant correlation between synovial thickening and extent of vascularity could be found (P = 0.089 to 0.097). Interobserver reliability was calculated to be excellent when evaluating the grading score (κ = 0.811 to 1.00). CEUS is a promising tool to detect tendon vascularity with higher sensitivity than PDUS by improved detection of intra- and peritendinous vascularity.

  11. Longitudinal microvascularity in achilles tendinopathy (power doppler ultrasound, magnetic resonance imaging time-intensity curves and the Victorian Institute of Sport Assessment-Achilles questionnaire): a pilot study

    International Nuclear Information System (INIS)

    Richards, Paula J.; McCall, Iain W.; Day, Christopher; Belcher, John; Maffulli, Nicola

    2010-01-01

    To evaluate the imaging of the natural history of Achilles tendinopathy microvascularisation in comparison with symptoms, using a validated disease-specific questionnaire [the Victorian Institute of Sport Assessment-Achilles (VISA-A)]. A longitudinal prospective pilot study of nine patients with post-contrast magnetic resonance imaging (MRI), time-intensity curve (TIC) enhancement, ultrasound (US) and power Doppler (PD) evaluation of tendinopathy of the mid-Achilles tendon undergoing conservative management (eccentric exercise) over 1 year. There were five men and four women [mean age 47 (range 30-62) years]. Six asymptomatic tendons with normal US and MRI appearance showed less enhancement than the tibial metaphysis did and showed a flat, constant, but very low rate of enhancement in the bone and Achilles tendon (9-73 arbitrary TIC units). These normal Achilles tendons on imaging showed a constant size throughout the year (mean 4.9 mm). At baseline the TIC enhancement in those with tendinopathy ranged from 90 arbitrary units to 509 arbitrary units. Over time, 11 abnormal Achilles tendons, whose symptoms settled, were associated with a reduction in MRI enhancement mirrored by a reduction in the number of vessels on power Doppler (8.0 to 2.7), with an improvement in morphology and a reduction in tendon size (mean 15-10.6 mm). One tendon did not change its abnormal imaging features, despite improving symptoms. Two patients developed contralateral symptoms and tendinopathy, and one had more abnormal vascularity on power Doppler and higher MRI TIC peaks in the asymptomatic side. In patient with conservatively managed tendinopathy of the mid-Achilles tendon over 1 year there was a reduction of MRI enhancement and number of vessels on power Doppler, followed by morphological improvements and a reduction in size. Vessels per se related to the abnormal morphology and size of the tendon rather than symptoms. Symptoms improve before the Achilles size reduces and the

  12. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  13. Synchronized epiaortic two-dimensional and color Doppler echocardiographic guidance enables routine ascending aortic cannulation in type A acute aortic dissection.

    Science.gov (United States)

    Inoue, Yoshito; Takahashi, Ryuichi; Ueda, Toshihiko; Yozu, Ryohei

    2011-02-01

    Preference for arterial inflow during surgery for type A acute aortic dissection remains controversial. Antegrade central perfusion prevents malperfusion and retrograde embolism, and the ascending aorta provides arterial access for rapid establishment of systemic perfusion, especially if there is hemodynamic instability. It has not been used routinely, however, because of the disruption caused to the aorta. We evaluated the safety and efficacy of routine cannulation of the dissected aorta for the repair of type A dissection. Surgical results were analyzed for 83 consecutive patients with type A acute aortic dissection between 2002 and 2009. They were treated surgically by prosthetic graft replacement under hypothermic circulatory arrest. The ascending aorta was routinely cannulated using the Seldinger technique with epiaortic echocardiographic guidance; antegrade systemic perfusion was evaluated by color Doppler ultrasound. Systemic antegrade perfusion via the dissected ascending aorta was performed safely in all cases. There was no malperfusion or thromboembolism as a result of ascending aortic cannulation. Epiaortic 2-dimensional and color Doppler imaging provided real-time monitoring adequate for the placement and for proper systemic perfusion. There were 5 in-hospital deaths (5/83=6.0%) and 8 strokes (preoperative 6/83=7.2%, postoperative 2/83=2.4%). A total of 78 patients (78/83=94%) were discharged and have been followed up without major adverse cardiac events for a mean duration of 31.8 months. Ascending aortic cannulation is a simple and safe technique that provides a rapid and reliable route of antegrade central systemic perfusion in type A aortic dissection. Copyright © 2011 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  14. Quantitative Assessment of Synovial Vascularity Using Contrast-Enhanced Power Doppler Ultrasonography: Correlation with Histologic Findings and MR Imaging Findings in Arthritic Rabbit Knee Model

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Shin, Myung Jin; Kim, Seong Moon; Kim, Namkug; Suh, Sang Hyun; Suh, Jin Suck

    2008-01-01

    To validate contrast-enhanced power Doppler ultrasonography (PD US) for the evaluation of synovial vascularity in an arthritic rabbit knee model in correlation with MR and histological findings. Power Doppler ultrasonography was performed for carrageenin-induced arthritic left knee and control right knee of 13 rabbits, first without and then with sonic contrast agent enhancement (Levovist, Schering, Berlin Germany), followed by gadolinium-enhanced MR imaging. Synovial vascularity was quantitatively assessed by calculating the color pixel area in power Doppler sonography using a computer-aided image analysis program and by grading the enhancement on MR images: grade 1, enhancement of knee joint is less than one-third of the area; grade 2, one-third to two-thirds enhancement; and grade 3, more than two-thirds enhancement. Microvessel density (MVD) was measured on slides stained immunohistochemically for CD31 antigen for histological assessment. The mean area of color pixels in PD US changed from 4.37 to 16.42 mm 2 in the arthritic knee after enhancement (p 2 in the control knee (p 0.05). Sonic contrast-enhanced PD US improves the visualization of synovial vascularity and allows quantitative measurement in experimentally induced rabbit arthritic knees

  15. Dimensional response of CANDU fuel to power changes

    Energy Technology Data Exchange (ETDEWEB)

    Fehrenbach, P J [Fuel Engineering Branch, Chalk River Nuclear Laboratories, Atomic Energy of Canada Limited, Chalk River, ON (Canada); Hastings, I J; Morel, P A; Sage, R D; Smith, A D [Fuel Materials Branch, Chalk River Nuclear Laboratories, Atomic Energy of Canada Limited, Chalk River, ON (Canada)

    1983-06-01

    The introduction of CANLUB-coated fuel cladding, modified fuel management schemes, and revisions to the sequence of control rod movements, have eliminated power ramping fuel failures in CANDU power reactors. However, an irradiation program continues at Chalk River Nuclear Laboratories to determine the effect of various design and operating parameters on the dimensional response of UO{sub 2} fuel elements to power changes, over a range of conditions outside those normally experienced by CANDU power reactor fuel. We have investigated the effect of power changes on element diameter for UO{sub 2} fuel with starting densities of 10.6 and 10.8 Mg/m{sup 3} clad in 0.4 mm thick Zircaloy, at burnups from 0 to 100 MW.h/kg U. Element diameter measurements were obtained at power using an In-Reactor Diameter Measuring Rig (IRDMR). Rates of power change over the range 0.0005 to 0.03 kW.m{sup -1}.s{sup -1} were achieved by a combination of reactor power control and use of a Helium-3 power cycling facility. Total diameter increases in unirradiated elements were about 1% at pellet interface locations for both fuel densities during the initial power increase to 60 kW/m. Diameter changes during subsequent power cycles of these elements from 55 to 100% maximum power were significantly larger for the higher density fuel, ranging from 0.3 to 0.5% compared to less than 0.1% for the standard density (10.6 Mg/m{sup 3}) fuel. In elements pre-irradiated at 27 kW/m to burnups of about 100 MW.h/kg U prior to power ramping, the diameter increases measured after ramping to 55 kW/m also varied with starting fuel density. Diameter changes at pellet interface locations were about 0.9% and 0.6% for higher density and standard density fuel respectively. (author)

  16. Feasibility and diagnostic power of transthoracic coronary Doppler for coronary flow velocity reserve in patients referred for myocardial perfusion imaging

    Directory of Open Access Journals (Sweden)

    Nylander Eva

    2008-03-01

    Full Text Available Abstract Background Myocardial perfusion imaging (MPI, using single photon emission computed tomography (SPECT is a validated method for detecting coronary artery disease. Transthoracic Doppler echocardiography (TTDE of flow at rest and during adenosine provocation has previously been evaluated in selected patient groups. We therefore wanted to compare the diagnostic ability of TTDE in the left anterior descending coronary artery (LAD to that of MPI in an unselected population of patients with chest pain referred for MPI. Our hypothesis was that TTDE with high accuracy would identify healthy individuals and exclude them from the need for further studies, enabling invasive investigations to be reserved for patients with a high probability of disease. Methods Sixty-nine patients, 44 men and 25 women, age 61 ± 10 years (range 35–82, with a clinical suspicion of stress induced myocardial ischemia, were investigated. TTDE was performed at rest and during adenosine stress for myocardial scintigraphy. Results We found that coronary flow velocity reserve (CFVR determined from diastolic measurements separated normal from abnormal MPI findings with statistical significance. TTDE identified coronary artery disease, defined from MPI, as reversible ischemia and/or permanent defect, with a sensitivity of 60% and a specificity of 79%. The positive predictive value was 43% and the negative predictive value was 88%. There was an overlap between groups which could be due to abnormal endothelial function in patients with normal myocardial perfusion having either hypertension or diabetes. Conclusion TTDE is an attractive non-invasive method to evaluate chest pain without the use of isotopes, but the diagnostic power is strongly dependent on the population investigated. Even in our heterogeneous clinical cardiac population, we found that CFVR>2 in the LAD excluded significant coronary artery disease detected by MPI.

  17. The value of power Doppler ultrasound in patients with rheumatoid arthritis in clinical remission: Reclassifying disease activity?

    Science.gov (United States)

    Vergara, Facundo; Ruta, Santiago; Rosa, Javier; Marín, Josefina; García-Mónaco, Ricardo; Soriano, Enrique R

    2017-03-18

    The aim of the present study was to describe the ultrasound (US) findings in patients with rheumatoid arthritis (RA) in clinical remission, and to evaluate the ability of power Doppler (PD) US to reclassify disease activity in these patients. We included consecutive patients with RA according to 2010 American College of Rheumatology/European League Against Rheumatism criteria, who were in clinical remission by the Disease Activity Score (DAS28<2.6). Twenty joints of both hands were assessed by US. PD signal was evaluated on a semi-quantitative scale from 0 to 3. Three different US-modified DAS28 (US-DAS28) were constructed, replacing the clinical swollen joint count by the PD US joint count using PD score ≥1, ≥2 or ≥3, respectively. Eighty-six patients were included. Twenty-three (26.7%) patients had at least one joint with abnormal US-positive PD signal. Thirteen percent of patients were reclassified to low disease activity by applying the US-DAS28 when joints were considered active with a PD signal ≥1; 12%, when a PD signal ≥2 was considered, and 2% of the patients were reclassified when a PD score of 3 was considered. No patients were reclassified to a level of moderate or high activity applying US-DAS28. Although around a quarter of patients with RA in clinical remission showed PD US features indicating residual activity, only a small percentage were reclassified to a state of low activity and none to a level of moderate or high activity, applying the proposed US-DAS28. Copyright © 2017 Elsevier España, S.L.U. and Sociedad Española de Reumatología y Colegio Mexicano de Reumatología. All rights reserved.

  18. Two dimensional radiated power diagnostics on Alcator C-Mod

    International Nuclear Information System (INIS)

    Reinke, M. L.; Hutchinson, I. H.

    2008-01-01

    The radiated power diagnostics for the Alcator C-Mod tokamak have been upgraded to measure two dimensional structure of the photon emissivity profile in order to investigate poloidal asymmetries in the core radiation. Commonly utilized unbiased absolute extreme ultraviolet (AXUV) diode arrays view the plasma along five different horizontal planes. The layout of the diagnostic set is shown and the results from calibrations and recent experiments are discussed. Data showing a significant, 30%-40%, inboard/outboard emissivity asymmetry during ELM-free H-mode are presented. The ability to use AXUV diode arrays to measure absolute radiated power is explored by comparing diode and resistive bolometer-based emissivity profiles for highly radiative L-mode plasmas seeded with argon. Emissivity profiles match in the core but disagree radially outward resulting in an underprediction of P rad of nearly 50% by the diodes compared to P rad determined using resistive bolometers.

  19. Two dimensional radiated power diagnostics on Alcator C-Moda)

    Science.gov (United States)

    Reinke, M. L.; Hutchinson, I. H.

    2008-10-01

    The radiated power diagnostics for the Alcator C-Mod tokamak have been upgraded to measure two dimensional structure of the photon emissivity profile in order to investigate poloidal asymmetries in the core radiation. Commonly utilized unbiased absolute extreme ultraviolet (AXUV) diode arrays view the plasma along five different horizontal planes. The layout of the diagnostic set is shown and the results from calibrations and recent experiments are discussed. Data showing a significant, 30%-40%, inboard/outboard emissivity asymmetry during ELM-free H-mode are presented. The ability to use AXUV diode arrays to measure absolute radiated power is explored by comparing diode and resistive bolometer-based emissivity profiles for highly radiative L-mode plasmas seeded with argon. Emissivity profiles match in the core but disagree radially outward resulting in an underprediction of Prad of nearly 50% by the diodes compared to Prad determined using resistive bolometers.

  20. Real-time three-dimensional color doppler evaluation of the flow convergence zone for quantification of mitral regurgitation: Validation experimental animal study and initial clinical experience

    Science.gov (United States)

    Sitges, Marta; Jones, Michael; Shiota, Takahiro; Qin, Jian Xin; Tsujino, Hiroyuki; Bauer, Fabrice; Kim, Yong Jin; Agler, Deborah A.; Cardon, Lisa A.; Zetts, Arthur D.; hide

    2003-01-01

    BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.

  1. NEW EVIDENCE OF MAGNETIC INTERACTIONS BETWEEN STARS FROM THREE-DIMENSIONAL DOPPLER TOMOGRAPHY OF ALGOL BINARIES: {beta} PER AND RS VUL

    Energy Technology Data Exchange (ETDEWEB)

    Richards, Mercedes T. [Department of Astronomy and Astrophysics, Pennsylvania State University, 525 Davey Laboratory, University Park, PA 16802 (United States); Agafonov, Michail I.; Sharova, Olga I., E-mail: mrichards@astro.psu.edu, E-mail: agfn@nirfi.sci-nnov.ru, E-mail: shol@nirfi.sci-nnov.ru [Radiophysical Research Institute (NIRFI), 25/12a, Bolshaya Pecherskaya St., Nizhny Novgorod 603950 (Russian Federation)

    2012-11-20

    Time-resolved H{alpha} spectra of magnetically active interacting binaries have been used to create three-dimensional (3D) Doppler tomograms by means of the Radioastronomical Approach. This is the first 3D reconstruction of {beta} Per, with RS Vul for comparison. These 3D tomograms have revealed evidence of the mass transfer process (gas stream, circumprimary emission, localized region, absorption zone), as well as loop prominences and coronal mass ejections (CMEs) in {beta} Per and RS Vul that could not be discovered from two-dimensional tomograms alone. The gas stream in both binaries may have been deflected beyond the central plane by the donor star's magnetic field. The stream was more elongated along the predicted trajectory in RS Vul than in {beta} Per, but not as pronounced as in U CrB (stream state). The loop prominence reached maximum V{sub z} velocities of {+-}155 km s{sup -1} in RS Vul compared to {+-}120 km s{sup -1} in {beta} Per, while the CME reached a maximum V{sub z} velocity of +150 km s{sup -1} in RS Vul and +100 km s{sup -1} in {beta} Per. The 3D tomograms show that the gas flows are not symmetric relative to the central plane and are not confined to that plane, a result confirmed by recent 15 GHz VLBI radio images of {beta} Per. Both the 3D H{alpha} tomography and the VLBI radio images support an earlier prediction of the superhump phenomenon in {beta} Per: that the gas between the stars is threaded with a magnetic field even though the hot B8V mass-gaining star is not known to have a magnetic field.

  2. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  3. Verification of the accuracy of Doppler broadened, self-shielded multigroup cross sections for fast power reactor applications

    International Nuclear Information System (INIS)

    Ganesan, S.; Gopalakrishnan, V.; Ramanadhan, M.M.; Cullen, D.E.

    1988-01-01

    Verification results for Doppler broadening and self-shielding are presented. One of the important results presented is that the original SIGMA1 method of numerical Doppler broadening has now been demonstrated to be inaccurate and not capable of producing results to within required accuracies. Fortunately, due to this study, the SIGMA1 method has been significantly improved and the new SIGMA1 is now capable of producing results to within required accuracies. Although this paper presents results based upon using only one code system, it is important to realize that the original SIGMA1 method is presently used in many cross-section processing code systems; the results of this paper indicate that unless these other code systems are updated to include the new SIGMA1 method, the results produced by these code systems could be very inaccurate. The objectives of the IAEA nuclear data processing code verification project are reviewed as well as the requirements for the accuracy of calculation of Doppler coefficients and the present status of these calculations. The initial results of Doppler broadening and self-shielding calculations are presented and the inconsistency of the results which led to the discovery of errors in the original SIGMA1 method of Doppler broadening are pointed out. Analysis of the errors found and improvements in the SIGMA1 method are presented. Improved results are presented in order to demonstrate that the new SIGMA1 method can produce results within required accuracies. Guidelines are presented to limit the uncertainty introduced due to cross-section processing in order to balance available computer resources to accuracy requirements. Finally cross-section processing code users are invited to participate in the IAEA processing code verification project in order to verify the accuracy of their calculated results. (author)

  4. Power Doppler ultrasonography for assessment of synovitis in the metacarpophalangeal joints of patients with rheumatoid arthritis: a comparison with dynamic magnetic resonance imaging

    DEFF Research Database (Denmark)

    Szkudlarek, Marcin; Court-Payen, M; Strandberg, C

    2001-01-01

    OBJECTIVE: To evaluate the effectiveness of power Doppler ultrasonography (PDUS) for assessing inflammatory activity in the metacarpophalangeal (MCP) joints of patients with rheumatoid arthritis (RA), using dynamic magnetic resonance imaging (MRI) as a reference method. METHODS: PDUS and dynamic...... MRI were performed on 54 MCP joints of 15 patients with active RA and on 12 MCP joints of 3 healthy controls. PDUS was performed with a LOGIQ 500 unit by means of a 7-13-MHz linear array transducer. Later the same day, MRI was performed with a 1.0T MR unit. A series of 24 coronal T1-weighted images...

  5. Fabrication of a PMN-PT Single Crystal-Based Transcranial Doppler Transducer and the Power Regulation of Its Detection System

    Directory of Open Access Journals (Sweden)

    Qingwen Yue

    2014-12-01

    Full Text Available Doppler sonographic measurement of flow velocity in the basal cerebral arteries through the intact skull was developed using a pulsed Doppler technique and 2 MHz emitting frequency. Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3O3-PbTiO3 (PMN-PT were chosen to be the piezoelectric transducer material due to their ultrahigh piezoelectric coefficients, high electromechanical coupling coefficients and low dielectric loss. The pulse-echo response of the transducer was measured using the conventional pulse-echo method in a water bath at room temperature. The −6 dB bandwidth of the transducer is 68.4% and the sensitivity is −17.4 dB. In order to get a good match between transducer and detection system, different transmission powers have been regulated by changing the impedance of the transmitting electric circuit. In the middle cerebral artery (MCA measurement photograph results, as the transmission power is increasing, the detection results become clearer and clearer. A comparison at the same transmission power for different transducers shows that the detection photograph obtained by the crystal transducer was clearer than that obtained with a commercial transducer, which should make it easier for doctors to find the cerebral arteries.

  6. Spatial weighting of Doppler reactivity feedback

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Todosow, M.

    1977-12-01

    The spatial weighting of the local Doppler feedback implicit in the determination of the core Doppler feedback reactivity has been investigated. Using a detailed planar PDQ7-II PWR model with local fuel-temperature feedback, the core Doppler spatial weight factor, S, has been determined for various control patterns and power levels. Assuming power-squared weighting of the local Doppler feedback, a simple analytic expression for S has been derived and, based on comparison with the PDQ7-II results, provides a convenient and accurate representation of the Doppler spatial weight factor. The sensitivity of these results to variations in the fuel rod heat transfer coefficients, fuel loading and the magnitude of the Doppler coefficient has also been evaluated. The dependence of the local Doppler coefficient on moderator temperature, boron concentration and control rod density has been determined and found to be weak. Selected comparisons with vendor analyses have been made and indicate general agreement

  7. Screening of Chronic Obstructive Pulmonary Disease Patients for Pulmonary Arterial Hypertension Using Two-Dimensional Transthoracic Doppler Echocardiography in Tertiary Care Hospital in India

    Directory of Open Access Journals (Sweden)

    Vinay Mahishale

    2015-01-01

    Full Text Available Background: Chronic obstructive pulmonary disease (COPD and pulmonary arterial hypertension (PAH are common and underdiagnosed medical conditions in India. Prevalence of these chronic diseases is high both in rural and urban areas. However, the exact prevalence of PAH in Indian COPD patients is unclear. Comorbid conditions like PAH have a great impact on the outcome of COPD in the form of severity, exacerbations, morbidity, and mortality. Right heart catheterization remains the gold standard test for diagnosis of PAH, but it is invasive and practically not feasible. Aims and objectives: The present study objective was to screen COPD patients for PAH using two-dimensional transthoracic Doppler echocardiography (ECHO in Tertiary Care Hospital. Results: A total of 2040 patients with a confirmed diagnosis of COPD were enrolled in the study. Among these patients, 1509 were males (73.9%, 531 were females (23.06%, and 1428 were known or ex-smokers (70%. None of the females were smokers, but there was a history of biomass fuel exposure for >10 years. As per global initiative for chronic obstructive lung disease criteria, mild, moderate, severe, and very severe COPD was noted in 525,629,511, and 375 patients, respectively. When they were screened using ECHO, prevalence of PAH was 41.96% as 856 subjects had PAH. Prevalence of PAH among mild, moderate, severe, and very severe COPD was 23.8%, 34.81%, 48.53%, and 70.4%, respectively. There was a linear relationship between PAH and severity of COPD. Conclusion: PAH is very common in COPD patients in India. As the severity of COPD increased, the frequency and degree of PAH also increased. ECHO is an excellent tool for detection of PAH in COPD patients. All patients with severe to very severe COPD should be routinely screened by ECHO for PAH and with mild to moderate COPD, who have dyspnea out of proportion to their clinical condition should also be screened for PAH.

  8. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  9. Effect of intertrochanteric osteotomy on the proximal femur of rabbits: assessment with power Doppler sonography and scintigraphy Efeito da osteotomia intertrocantérica no femur proximal de coelhos: avaliação com utra-sonografia power Doppler e cintilografia

    Directory of Open Access Journals (Sweden)

    Andrea S. Doria

    2007-01-01

    Full Text Available OBJECTIVE: In bone injury, repair results in local increased vascularity and bone marrow remodeling. Characterizing the vascular and metabolic imaging patterns of the proximal femur following an intertrochanteric osteotomy may help clinicians decide proper management of the patient. Our objective was to measure Doppler sonography and scintigraphy interval changes in the proximal femur following intertrochanteric osteotomy and compare imaging and histomorphometric measurements in the late post-operative stage (6 weeks after surgery in a rabbit model of bone injury. MATERIALS AND METHODS: Both hips of 12 adult rabbits were imaged with power Doppler sonography and scintigraphy prior to and after (7 days and 6 weeks unilateral osteotomy. Accuracy of the imaging methods was evaluated using hip operative status and histomorphometric results (vascular fractional area and number of vessels per area unit as reference standard measures. RESULTS: A significant difference in the mean number of pixels was noted between operated and non-operated femura in late post-operative power Doppler examinations (P=0.049. Although without reaching statistical significance, the AUC of Doppler measurements (AUC=0.99 was numerically greater than the AUC of scintigraphy measurements (AUC=0.857±0.099 (P=0.15 in differentiating proximal femura with regard to their fractional vascular areas in the late post-operative stage. In contrast, scintigraphy tended to perform better (AUC=0.984±0.022 than Doppler ultrasound (AUC=0.746±0.131 to demonstrate the vascularity intensity per area unit (P=0.07 in the late stage. CONCLUSION: Our results warrant further investigation to determine the value of different imaging modalities for assessment of pathologic changes following hip surgery. Power Doppler sonography demonstrated larger AUCs (representing higher accuracy for the discrimination of vascular fractional areas and scintigraphy, for discrimination of the number of vessels per

  10. Two dimensional and Doppler echocardiographic evaluation of patients presenting at Obafemi Awolowo University Teaching Hospitals Complex Ile Ife Nigeria a prospective study of 2501 subjects

    Directory of Open Access Journals (Sweden)

    Adebayo RA

    2013-07-01

    Full Text Available Rasaaq Ayodele Adebayo,1 Patience Olayinka Akinwusi,2 Michael Olabode Balogun,1 Anthony Olubunmi Akintomide,1 Victor Oladeji Adeyeye,1 Olugbenga Olusola Abiodun,1 Luqman Adeleke Bisiriyu,3 Suraj Adefabi Ogunyemi,1 Ebenezer Adekunle Ajayi,4 Olufemi Eyitayo Ajayi,1 Adebayo Tolulope Oyedeji5 1Cardiology Unit, Department of Medicine, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Osun State, 2Cardiology Unit, Department of Medicine, Osun State University, Osogbo, Osun State, 3Department of Demography and Social Statistics, Obafemi Awolowo University, Ile-Ife, Osun State, 4Cardiology Unit, Department of Medicine, Ekiti State University Teaching Hospital, Ado-Ekiti, Ekiti State, 5Cardiology Unit, Department of Medicine, LAUTECH Teaching Hospital, Osogbo, Osun State, Nigeria Background: Echocardiography remains a key noninvasive cardiac investigative tool in the management of patients, especially in a developing economy like Nigeria. In this study, we investigated the indications for transthoracic echocardiography and spectrum of cardiac disease found in patients referred to our cardiac unit for echocardiography. Methods: A prospective two-dimensional, pulsed, continuous, and color-flow Doppler echocardiographic evaluation was done using the transthoracic approach in 2501 patients over an eight-year period. Univariate data analysis was performed for mean age, gender, clinical indications, and diagnoses. Results: The subject age range was less than 12 months to 97 years (mean 52.39 years. There were 1352 (54.06% males and 1149 (45.94% females. The most common indication for echocardiography was hypertension (52.1% followed by congestive cardiac failure (13.9%. Others were for screening (6.1%, arrhythmias (5%, cerebrovascular disease (5%, chest pain (3.3%, chronic kidney disease (3.2%, congenital heart disease (2.6%, cardiomyopathy (1.8%, rheumatic heart disease (1.7%, diabetes mellitus (1.3%, thyrocardiac disease (1.2%, ischemic heart

  11. Concordance and reproducibility between M-mode, tissue Doppler imaging, and two-dimensional strain imaging in the assessment of mitral annular displacement and velocity in patients with various heart conditions

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Biering-Sorensen, Tor; Sogaard, Peter

    2014-01-01

    AIMS: Mitral annular (MA) displacement reflects longitudinal left ventricular (LV) deformation and systolic velocity measurements reflect the rate of contraction; both are valuable in the diagnosis and prognosis of cardiac disease. The aim of this study was to test the agreement and reproducibility...... between motion mode (M-mode), colour tissue Doppler imaging (TDI), and two-dimensional strain imaging (2DSI) when measuring MA displacement and systolic velocity. METHODS AND RESULTS: Using GE Healthcare Vivid 7 and E9 and Echopac BT11 software, MA displacement and velocity measurements by 2DSI, TDI...

  12. Quantum Effects in the Thermoelectric Power Factor of Low-Dimensional Semiconductors.

    Science.gov (United States)

    Hung, Nguyen T; Hasdeo, Eddwi H; Nugraha, Ahmad R T; Dresselhaus, Mildred S; Saito, Riichiro

    2016-07-15

    We theoretically investigate the interplay between the confinement length L and the thermal de Broglie wavelength Λ to optimize the thermoelectric power factor of semiconducting materials. An analytical formula for the power factor is derived based on the one-band model assuming nondegenerate semiconductors to describe quantum effects on the power factor of the low-dimensional semiconductors. The power factor is enhanced for one- and two-dimensional semiconductors when L is smaller than Λ of the semiconductors. In this case, the low-dimensional semiconductors having L smaller than their Λ will give a better thermoelectric performance compared to their bulk counterpart. On the other hand, when L is larger than Λ, bulk semiconductors may give a higher power factor compared to the lower dimensional ones.

  13. Atomic stopping-power problems encountered in measurements of nuclear γ-ray lifetimes by the Doppler-shift-attenuation method

    International Nuclear Information System (INIS)

    Latta, B.M.; Scanlon, P.J.

    1976-01-01

    The value of the nuclear lifetime of the 3.34-MeV level in 22 Ne as determined by Broude et al. by the Doppler shift attenuation method exhibits variations depending on the atomic number Z 2 of the slowing down medium. The lifetime has been re-evaluated within the framework of the Lindhard-Winther stopping theory, assuming a simple approximate form for the density of electrons associated with an atom in a solid and an effective point charge for the projectile based on experimental stopping powers. Although there are still variations in the value of the lifetime the variations appear to be systematic through the region of the transition elements. (Auth.)

  14. Acute pyelonephritis in pediatric age: comparative study between power Doppler ultrasound scan and DMSA; Pielonefritis aguda en la edad pediatrica: estudio comparative entre la ecografiapower-Doppler y el DMSA

    Energy Technology Data Exchange (ETDEWEB)

    Muro, M. D.; Sanguesa, C.; Otero, M. C.; Piqueras, A. I.; Lloret, M. T. [Hospital Infantil Universitario La Fe. Valencia (Spain)

    2002-07-01

    To evaluate the usefulness of power Doppler (PD) Ultrasound Scan in the study of acute pyelonephritis (APN). To compare ultrasound scan results with those obtained with renal gammagraphy (DMSA). To relate the findings to the clinical criteria and to determine the presence of vesicoureteral reflux (VUR) in the serial micturition cystography (SMC). Prospective study of 92 patients (ages between 1 month and 10 years) with suspected clinical PNA. All children were initially subjected to PD ultrasound scan and DMSA. Those under 3 years old were also subjected to SMC for the study of VUR. PNA in the PD ultrasound scan was manifested by decrease in vascularisation and in the DMSA by decrease in caption in the affected zones. 87 renal units (RU) with PNA foci were detected. Conformity between the PD ultrasound scan and DMSA was 157 RU (92%): 52 positives, 22 negatives with PNA and 83 normal RU. The sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 65.5% and 69.0%. 51 SMC were performed, with VUR being detected in 18 (13 bilateral and 5 unilateral), in which the sensitivities of PD and DMSA were 80% and 85%, respectively. Mode B ultrasound scan and PD can replace DMSA in the initial study of PPNA. It is non-invasive, simple, economical and just as reliable as DMSA in expert hands. it can also postpone by up to 6 months the need to perform DMSA for detection of permanent renal damage. (Author) 22 refs.

  15. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  16. Vascularization of liver tumors - preliminary results with Coded Harmonic Angio (CHA), phase inversion imaging, 3D power Doppler and contrast medium-enhanced B-flow with second generation contrast agent (Optison).

    Science.gov (United States)

    Jung, E M; Kubale, R; Jungius, K-P; Jung, W; Lenhart, M; Clevert, D-A

    2006-01-01

    To investigate the dynamic value of contrast medium-enhanced ultrasonography with Optison for appraisal of the vascularization of hepatic tumors using harmonic imaging, 3D-/power Doppler and B-flow. 60 patients with a mean age of 56 years (range 35-76 years) with 93 liver tumors, including histopathologically proven hepatocellular carcinoma (HCC) [15 cases with 20 lesions], liver metastases of colorectal tumors [17 cases with 33 lesions], metastases of breast cancer [10 cases with 21 lesions] and hemangiomas [10 cases with 19 lesions] were prospectively investigated by means of multislice CT as well as native and contrast medium-enhanced ultrasound using a multifrequency transducer (2.5-4 MHz, Logig 9, GE). B scan was performed with additional color and power Doppler, followed by a bolus injection of 0.5 ml Optison. Tumor vascularization was evaluated with coded harmonic angio (CHA), pulse inversion imaging with power Doppler, 3D power Doppler and in the late phase (>5 min) with B-flow. In 15 cases with HCC, i.a. DSA was performed in addition. The results were also correlated with MRT and histological findings. Compared to spiral-CT/MRT, only 72/93 (77%) of the lesions could be detected in the B scan, 75/93 (81%) with CHA and 93/93 (100%) in the pulse inversion mode. Tumor vascularization was detectable in 43/93 (46%) of lesions with native power Doppler, in 75/93 (81%) of lesions after administering contrast medium in the CHA mode, in 81/93 (87%) of lesions in the pulse inversion mode with power Doppler and in 77/93 (83%) of lesions with contrast-enhanced B-flow. Early arterial and capillary perfusion was best detected with CHA, particularly in 20/20 (100%) of the HCC lesions, allowing a 3D reconstruction. 3D power Doppler was especially useful in investigating the tumor margins. Up to 20 min after contrast medium injection, B-flow was capable of detecting increased metastatic tumor vascularization in 42/54 (78%) of cases and intratumoral perfusion in 17/20 (85

  17. Adaptive Spectral Doppler Estimation

    DEFF Research Database (Denmark)

    Gran, Fredrik; Jakobsson, Andreas; Jensen, Jørgen Arendt

    2009-01-01

    . The methods can also provide better quality of the estimated power spectral density (PSD) of the blood signal. Adaptive spectral estimation techniques are known to pro- vide good spectral resolution and contrast even when the ob- servation window is very short. The 2 adaptive techniques are tested......In this paper, 2 adaptive spectral estimation techniques are analyzed for spectral Doppler ultrasound. The purpose is to minimize the observation window needed to estimate the spectrogram to provide a better temporal resolution and gain more flexibility when designing the data acquisition sequence...... and compared with the averaged periodogram (Welch’s method). The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set...

  18. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  19. A Wearable Transcranial Doppler Ultrasound Phased Array System.

    Science.gov (United States)

    Pietrangelo, Sabino J; Lee, Hae-Seung; Sodini, Charles G

    2018-01-01

     Practical deficiencies related to conventional transcranial Doppler (TCD) sonography have restricted its use and applicability. This work seeks to mitigate several such constraints through the development of a wearable, electronically steered TCD velocimetry system, which enables noninvasive measurement of cerebral blood flow velocity (CBFV) for monitoring applications with limited operator interaction. A highly-compact, discrete prototype system was designed and experimentally validated through flow phantom and preliminary human subject testing. The prototype system incorporates a custom two-dimensional transducer array and multi-channel transceiver electronics, thereby facilitating acoustic beamformation via phased array operation. Electronic steering of acoustic energy enables algorithmic system controls to map Doppler power throughout the tissue volume of interest and localize regions of maximal flow. Multi-focal reception permits dynamic vessel position tracking and simultaneous flow velocimetry over the time-course of monitoring. Experimental flow phantom testing yielded high correlation with concurrent flowmeter recordings across the expected range of physiological flow velocities. Doppler power mapping has been validated in both flow phantom and preliminary human subject testing, resulting in average vessel location mapping times testing. A wearable prototype CBFV measurement system capable of autonomous vessel search and tracking has been presented. Although flow phantom and preliminary human validation show promise, further human subject testing is necessary to compare velocimetry data against existing commercial TCD systems. Additional human subject testing must also verify acceptable vessel search and tracking performance under a variety of subject populations and motion dynamics-such as head movement and ambulation.

  20. Semiquantitative Evaluation of Extrasynovial Soft Tissue Inflammation in the Shoulders of Patients with Polymyalgia Rheumatica and Elderly-Onset Rheumatoid Arthritis by Power Doppler Ultrasound.

    Science.gov (United States)

    Suzuki, Takeshi; Yoshida, Ryochi; Okamoto, Akiko; Seri, Yu

    2017-01-01

    Objectives . To develop a scoring system for evaluating the extrasynovial soft tissue inflammation of the shoulders in patients with polymyalgia rheumatica (PMR) and elderly-onset rheumatoid arthritis with PMR-like onset (pm-EORA) using ultrasound. Methods . We analyzed stored power Doppler (PD) images obtained by the pretreatment examination of 15 PMR patients and 15 pm-EORA patients. A semiquantitative scoring system for evaluating the severity of PD signals adjacent to the anterior aspect of the subscapularis tendon was designed. Results . A four-point scale scoring for the hyperemia on the subscapularis tendon was proposed as follows in brief: 0 = absent or minimal flow, 1 = single vessel dots or short linear-shape signals, 2 = long linear-shape signals or short zone-shape signals, or 3 = long zone-shape signals. This scoring system showed good intra- and interobserver reliability and good correlation to quantitative pixel-counting evaluation. By using it, we demonstrated that inflammation in PMR is dominantly localized in extrasynovial soft tissue as compared with pm-EORA. Conclusions . We proposed a reliable semiquantitative scoring system using ultrasound for the evaluation of extrasynovial soft tissue inflammation of the shoulders in patients with both PMR and pm-EORA. This system is simple to use and can be utilized in future investigations.

  1. Quantitative analysis of thyroid tumors vascularity: A comparison between 3-D contrast-enhanced ultrasound and 3-D Power Doppler on benign and malignant thyroid nodules.

    Science.gov (United States)

    Caresio, Cristina; Caballo, Marco; Deandrea, Maurilio; Garberoglio, Roberto; Mormile, Alberto; Rossetto, Ruth; Limone, Paolo; Molinari, Filippo

    2018-05-15

    To perform a comparative quantitative analysis of Power Doppler ultrasound (PDUS) and Contrast-Enhancement ultrasound (CEUS) for the quantification of thyroid nodules vascularity patterns, with the goal of identifying biomarkers correlated with the malignancy of the nodule with both imaging techniques. We propose a novel method to reconstruct the vascular architecture from 3-D PDUS and CEUS images of thyroid nodules, and to automatically extract seven quantitative features related to the morphology and distribution of vascular network. Features include three tortuosity metrics, the number of vascular trees and branches, the vascular volume density, and the main spatial vascularity pattern. Feature extraction was performed on 20 thyroid lesions (ten benign and ten malignant), of which we acquired both PDUS and CEUS. MANOVA (multivariate analysis of variance) was used to differentiate benign and malignant lesions based on the most significant features. The analysis of the extracted features showed a significant difference between the benign and malignant nodules for both PDUS and CEUS techniques for all the features. Furthermore, by using a linear classifier on the significant features identified by the MANOVA, benign nodules could be entirely separated from the malignant ones. Our early results confirm the correlation between the morphology and distribution of blood vessels and the malignancy of the lesion, and also show (at least for the dataset used in this study) a considerable similarity in terms of findings of PDUS and CEUS imaging for thyroid nodules diagnosis and classification. © 2018 American Association of Physicists in Medicine.

  2. Are microbubbles free flowing tracers through the Myocardium? Comparison of indicator-dilution curves obtained from dye dilution and echo contrast using harmonic power Doppler imaging.

    Science.gov (United States)

    Tiemann, K; Schlosser, T; Pohl, C; Bimmel, D; Wietasch, G; Hoeft, A; Likungu, J; Vahlhaus, C; Kuntz, S; Nanda, N C; Becher, H; Lüderitz, B

    2000-01-01

    Harmonic power Doppler imaging (H-PDI) has been introduced into the field of contrast echocardiography as a contrast-specific imaging modality. However, there has been considerable skepticism as to whether H-PDI would be quantifiable, because it depends on the destruction of microbubbles and has more complex signal processing than gray scale imaging. The aim of the present study was to evaluate the relationship between the concentration of microbubbles and the resulting H-PDI signals even under conditions where bubble destruction is most likely. Furthermore, we evaluated whether microbubbles of Levovist freely pass the microcirculation, which is a prerequisite for the assessment of myocardial blood flow. A strong positive correlation was found between the H-PDI signals and the amount of microbubbles up to the onset of acoustic shadowing (r = 0. 968, Pgreen (ICG) in both a flow phantom and a working heart setup. The mean transit times (MTTs) through the myocardium of both agents were compared after a bolus injection into the left coronary artery. A close correlation was observed between 1/MTT and flow in both setups (r>0.98, Pgreen. We conclude that microbubbles fulfill the prerequisites of free flowing tracers through the myocardium. Furthermore, H-PDI technology allows a reliable assessment of time-concentration curves of air-filled microbubbles up to the onset of acoustic shadowing.

  3. Evaluation of residual hepatocellular carcinoma after transcatheter arterial chemoembolization: Comparison between contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography

    International Nuclear Information System (INIS)

    Kim, Seung Hoon; Lim, Hyo Keun; Lee, Won Jae

    2001-01-01

    To evaluate the effectiveness of contrast-enhanced helical CT and contrast-enhanced power doppler ultrasonography (PDUS) in assessing the therapeutic effect of transcatheter arterial chemoembolization (TACE) in hepatocellular carcinomas (HCCs). The follow-up contrast-enhanced helical CT and contrast-enhanced PDUS were performed for twenty-nine nodular HCCs from twelve patients previously treated with TACE. We defined the residual HCCs as intratumoral enhancing area on contrast-enhanced helical CT and color signal on contrast-enhanced PDUS. The interval between two examinations was less than 2 weeks (mean, 9 days). Two radiologists evaluated two examinations by consensus, and the results of these two examination were compared with the findings of other examinations including CT, angiography, and/or pathology to calculate the sensitivity, specificity and accuracy of two examinations. Of the 29 HCCs, 20 had residual HCCs whereas no residual HCCs in 9 HCCs on pathologic examination and/or follow-up radiologic study. The sensitivity, sensitivity and accuracy of contrast-enhanced helical CT were 65 (13/20), 89 (8/9), and 72% (21/29) while those of contrast-enhanced PDUS were 100 (20/20), 89 (8/9) and 97% (28/29), respectively. A microbubble contrast-enhanced PDUS was more effective in the detection of residual tumor in HCCs following TACE than contrast-enhanced helical CT.

  4. Limiting overdiagnosis of low-risk prostate cancer through an evaluation of the predictive value of transrectal and power Doppler ultrasonography.

    Science.gov (United States)

    Sauvain, Jean Luc; Sauvain, Elise; Papavero, Roger; Louis, Didier; Rohmer, Paul

    2016-12-01

    Overdiagnosis induced by prostate cancer screening makes necessary a better selection of candidate patients for prostate biopsy. The objective of our study is to assess the probability of having a high- or low-risk lesion that could require active surveillance (AS) after biopsies and a normal or abnormal examination, including transrectal and power Doppler ultrasonography (TRUS-PDS). Four hundred and twenty-nine consecutive patients with a PSA level risk of a biological recurrence and Dall'Era's criteria to assess possible AS. The TRUS-PDS was considered positive if one biopsy was positive in the same sextant as the suspect image. One hundred and seventy-seven out of 429 (41 %) T1c cancers were diagnosed; 131 out of 177 (74 %) could be qualified as low risk, and 119 out of 177 (67 %) could require AS. The TRUS-PDS was normal in 285 of 429 patients (66 %). With a normal TRUS-PDS, the probability of not having cancer with a high or intermediate risk was 96 % (negative predictive value). With an abnormal TRUS-PDS, the probability of having a positive biopsy was 59 %, and the probability of having a significant cancer was 30 %, according to the Dall'Era criteria. When TRUS-PDS was normal, these probabilities significantly decreased to 32 and 5 %, respectively ( p  risk of high- or intermediate-risk cancer.

  5. Automated Visualization and Quantification of Spiral Artery Blood Flow Entering the First-Trimester Placenta, Using 3-D Power Doppler Ultrasound.

    Science.gov (United States)

    Stevenson, Gordon N; Noble, J Alison; Welsh, Alec W; Impey, Lawrence; Collins, Sally L

    2018-03-01

    The goal of our research was to quantify the placental vascularity in 3-D at 11-13 + 6 wk of pregnancy at precise distances from the utero-placental interface (UPI) using 3-D power Doppler ultrasound. With this automated image analysis technique, differences in vascularity between normal and pathologic pregnancies may be observed. The algorithm was validated using a computer-generated image phantom and applied retrospectively in 143 patients. The following features from the PD data were recorded: The number of spiral artery jets into the inter-villous space, total geometric and PD area. These were automatically measured at discrete millimeter distances from the UPI. Differences in features were compared with pregnancy outcomes: Pre-eclamptic versus normal, all small-for-gestational age (SGA) to appropriate-for-gestational age (AGA) patients and AGA versus SGA in normotensives (Mann-Whitney). The Benjamini-Hochberg procedure was used (false discovery rate 10%) for multiple comparison testing. Features decreased with increasing distance from the UPI (Kruskal-Wallis test; p  0.05). This method provides a new in-vivo imaging tool for examining spiral artery development through pregnancy. Size and number of entrances of blood flow into the UPI could potentially be used to identify high-risk pregnancies and may provide a new imaging biomarker for placental insufficiency. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  6. Two dimensional simulation of high power laser-surface interaction

    International Nuclear Information System (INIS)

    Goldman, S.R.; Wilke, M.D.; Green, R.E.L.; Johnson, R.P.; Busch, G.E.

    1998-01-01

    For laser intensities in the range of 10 8 --10 9 W/cm 2 , and pulse lengths of order 10 microsec or longer, the authors have modified the inertial confinement fusion code Lasnex to simulate gaseous and some dense material aspects of the laser-matter interaction. The unique aspect of their treatment consists of an ablation model which defines a dense material-vapor interface and then calculates the mass flow across this interface. The model treats the dense material as a rigid two-dimensional mass and heat reservoir suppressing all hydrodynamic motion in the dense material. The computer simulations and additional post-processors provide predictions for measurements including impulse given to the target, pressures at the target interface, electron temperatures and densities in the vapor-plasma plume region, and emission of radiation from the target. The authors will present an analysis of some relatively well diagnosed experiments which have been useful in developing their modeling. The simulations match experimentally obtained target impulses, pressures at the target surface inside the laser spot, and radiation emission from the target to within about 20%. Hence their simulational technique appears to form a useful basis for further investigation of laser-surface interaction in this intensity, pulse-width range. This work is useful in many technical areas such as materials processing

  7. Novel Power Electronics Three-Dimensional Heat Exchanger: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Bennion, K.; Cousineau, J.; Lustbader, J.; Narumanchi, S.

    2014-08-01

    Electric drive systems for vehicle propulsion enable technologies critical to meeting challenges for energy, environmental, and economic security. Enabling cost-effective electric drive systems requires reductions in inverter power semiconductor area. As critical components of the electric drive system are made smaller, heat removal becomes an increasing challenge. In this paper, we demonstrate an integrated approach to the design of thermal management systems for power semiconductors that matches the passive thermal resistance of the packaging with the active convective cooling performance of the heat exchanger. The heat exchanger concept builds on existing semiconductor thermal management improvements described in literature and patents, which include improved bonded interface materials, direct cooling of the semiconductor packages, and double-sided cooling. The key difference in the described concept is the achievement of high heat transfer performance with less aggressive cooling techniques by optimizing the passive and active heat transfer paths. An extruded aluminum design was selected because of its lower tooling cost, higher performance, and scalability in comparison to cast aluminum. Results demonstrated a heat flux improvement of a factor of two, and a package heat density improvement over 30%, which achieved the thermal performance targets.

  8. Assessment of strain and strain rate by two-dimensional speckle tracking in mice: comparison with tissue Doppler echocardiography and conductance catheter measurements.

    Science.gov (United States)

    Ferferieva, V; Van den Bergh, A; Claus, P; Jasaityte, R; La Gerche, A; Rademakers, F; Herijgers, P; D'hooge, J

    2013-08-01

    This study was designed in order to compare the strain and strain rate deformation parameters assessed by speckle tracking imaging (STI) with those of tissue Doppler imaging (TDI) and conductance catheter measurements in chronic murine models of left ventricular (LV) dysfunction. Twenty-four male C57BL/6J mice were assigned to wild-type (n = 8), myocardial infarction (n = 8) and transaortic constriction (n = 8) groups. Echocardiographic and conductance measurements were simultaneously performed at rest and during dobutamine infusion (5 µg/kg/min) in all animals 10 weeks post-surgery. The LV circumferential strain (Scirc) and the strain rate (SRcirc) were derived from grey scale and tissue Doppler data at frame rates of 224 and 375 Hz, respectively. Scirc and SRcirc by TDI/STI correlated well with the preload recruitable stroke work (PRSW) (r = -0.64 and -0.71 for TDI; r = -0.46 and -0.50 for STI, P < 0.05). Both modalities showed a good agreement with respect to Scirc and SRcirc (r = 0.60 and r = 0.63, P < 0.05). During stress, however, TDI-estimated Scirc and SRcirc values were predominantly higher than those measured by STI (P < 0.05). The similarity of Scirc and SRcirc measurements with respect to the STI/TDI data was examined by the Bland-Altman analysis. In mice, the STI- and TDI-derived strain and strain rate deformation parameters relate closely to intrinsic myocardial function. At low heart rate-to-frame rate ratios (HR/FR), both STI and TDI are equally acceptable for assessing the LV function non-invasively in these animals. At HR/FR (e.g. dobutamine challenge), however, these methods cannot be used interchangeably as STI underestimates S and SR at high values.

  9. Consistent calculation of the stopping power for slow ions in two-dimensional electron gases

    International Nuclear Information System (INIS)

    Wang, You-Nian; Ma, Teng-Gai

    1997-01-01

    Within the framework of quantum scattering theory, we present a consistent calculation of the stopping power for slow protons and antiprotons moving in two-dimensional electron gases. The Friedel sum rule is used to determine the screening constant in the scattering potential. For the stopping power our results are compared with that of the random-phase approximation dielectric theory and that predicted by the linear Thomas-Fermi potential. copyright 1997 The American Physical Society

  10. Recognition method for three-dimensional image in dismantling of nuclear power plant

    International Nuclear Information System (INIS)

    Chino, Koichi.

    1993-01-01

    The present invention constitutes three-dimensional images of structures, in a short period of time, at a place where a man can hardly access upon dismantling of a large scaled nuclear power facilities contaminated by radioactive materials. That is, a television set is disposed on a movable rack. Images of structures as an objective are taken and compared with previously inputted data, to constitute rough images. The television set is moved to an evaluated position where a view angle changes sufficiently based on the rough images. Images of the objective structures are taken at the position after movement. A plurality of thus obtained images and previously stored information concerning the structures are compared, examined and corrected if required, and the three-dimensional images of the objective structures are recognized. According to the present invention, the three-dimensional images of the structures in the nuclear power plant can be recognized automatically at high accuracy by one television set. (I.S.)

  11. One-dimensional modelling of limit-cycle oscillation and H-mode power scaling

    DEFF Research Database (Denmark)

    Wu, Xingquan; Xu, Guosheng; Wan, Baonian

    2015-01-01

    To understand the connection between the dynamics of microscopic turbulence and the macroscale power scaling in the L-I-H transition in magnetically confined plasmas, a new time-dependent, one-dimensional (in radius) model has been developed. The model investigates the radial force balance equati...

  12. Grade and location of power Doppler are predictive of damage progression in rheumatoid arthritis patients in clinical remission by anti-tumour necrosis factor α.

    Science.gov (United States)

    Raffeiner, Bernd; Grisan, Enrico; Botsios, Costantino; Stramare, Roberto; Rizzo, Gaia; Bernardi, Livio; Punzi, Leonardo; Ometto, Francesca; Doria, Andrea

    2017-08-01

    To investigate power Doppler (PD) signal, grade and location and their association with radiographic progression in RA patients in remission. A prospective observational study was conducted in 125 consecutive RA patients in stable 28-joint DAS (DAS28) remission (⩾6 months) achieved on anti-TNF-α. At baseline, patients in stable remission underwent radiographic and US examination of the wrists and MCP, PIP and MTP joints. Semi-quantitative PD scoring (0-3) was recorded. We scored PD according to two locations: capsular or within synovial tissue without bone contact (location 1) and with bone contact or penetrating bone cortex (location 2). Radiographic progression was evaluated at the 1 year follow-up and defined as a change in van der Heijde-modified total Sharp score >0. Risk ratios (RRs) of radiographic progression according to presence, grade and location of PD were calculated. Four patients were excluded because of missing data. At baseline, 59/121 (48.7%) patients had a PD signal in one or more joints. PD location 2 was found in 74.6% patients (44/59). At the 1 year follow-up, 17/121 patients experienced radiographic progression: all had PD signal in one or more joints at baseline (RR 2.47, P location 2 (RR 3.49, P < 0.0001). Higher PD grades and PD in contact with/or penetrating bone are associated with radiographic progression in patients in DAS28 remission. © The Author 2017. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  13. Calprotectin and TNF trough serum levels identify power Doppler ultrasound synovitis in rheumatoid arthritis and psoriatic arthritis patients in remission or with low disease activity.

    Science.gov (United States)

    Inciarte-Mundo, José; Ramirez, Julio; Hernández, Maria Victoria; Ruiz-Esquide, Virginia; Cuervo, Andrea; Cabrera-Villalba, Sonia Raquel; Pascal, Mariona; Yagüe, Jordi; Cañete, Juan D; Sanmarti, Raimon

    2016-07-08

    Serum levels of calprotectin, a major S100 leucocyte protein, are associated with disease activity in rheumatoid arthritis (RA) and psoriatic arthritis (PsA) patients. Higher drug trough serum levels are associated with good response in patients treated with tumour necrosis factor inhibitors (TNFi). Power Doppler ultrasound (PDUS) synovitis is predictive of flare and progression of structural damage in patients in clinical remission. The purpose of this study was to analyse the accuracy of calprotectin and TNFi trough serum levels in detecting PDUS synovitis in RA and PsA patients in clinical remission or with low disease activity who were receiving TNFi. We conducted a cross-sectional study of 92 patients (42 with RA, 50 with PsA) receiving adalimumab (ADA), etanercept (ETN) or infliximab who were in remission or had low disease activity (28-joint Disease Activity Score based on erythrocyte sedimentation rate ultrasound scores (all r coefficients >0.50 in RA). Calprotectin correlated with the PDUS synovitis score in patients treated with ADA and ETN. Using PDUS synovitis (yes or no) as the reference variable, calprotectin had an AUC of 0.826. The best cut-off was ≥1.66 μg/ml, with a likelihood ratio of 2.77. C-reactive protein (AUC 0.673) and erythrocyte sedimentation rate (AUC 0.731) had a lower discriminatory capacity. TNFi trough serum levels were significantly associated with PDUS synovitis (OR 0.67, 95 % CI 0.52-0.85, p < 0.001) but their accuracy (AUC <0.5) was less than that of calprotectin. TNFi trough serum levels were inversely correlated with calprotectin and PDUS synovitis in RA and PsA patients receiving ADA and ETN. Calprotectin and TNFi trough serum levels may help identify PDUS synovitis in RA and PsA patients in clinical remission or with low disease activity.

  14. Power Doppler signal calibration between ultrasound machines by use of a capillary-flow phantom for pannus vascularity in rheumatoid finger joints: a basic study.

    Science.gov (United States)

    Sakano, Ryosuke; Kamishima, Tamotsu; Nishida, Mutsumi; Horie, Tatsunori

    2015-01-01

    Ultrasound allows the detection and grading of inflammation in rheumatology. Despite these advantages of ultrasound in the management of rheumatoid patients, it is well known that there are significant machine-to-machine disagreements regarding signal quantification. In this study, we tried to calibrate the power Doppler (PD) signal of two models of ultrasound machines by using a capillary-flow phantom. After flow velocity analysis in the perfusion cartridge at various injection rates (0.1-0.5 ml/s), we measured the signal count in the perfusion cartridge at various injection rates and pulse repetition frequencies (PRFs) by using PD, perfusing an ultrasound micro-bubble contrast agent diluted with normal saline simulating human blood. By use of the data from two models of ultrasound machines, Aplio 500 (Toshiba) and Avius (Hitachi Aloka), the quantitative PD (QPD) index [the summation of the colored pixels in a 1 cm × 1 cm rectangular region of interest (ROI)] was calculated via Image J (internet free software). We found a positive correlation between the injection rate and the flow velocity. In Aplio 500 and Avius, we found negative correlations between the PRF and the QPD index when the flow velocity was constant, and a positive correlation between flow velocity and the QPD index at constant PRF. The equation for the relationship of the PRF between Aplio 500 and Avius was: y = 0.023x + 0.36 [y = PRF of Avius (kHz), x = PRF of Aplio 500 (kHz)]. Our results suggested that the signal calibration of various models of ultrasound machines is possible by adjustment of the PRF setting.

  15. Comparison of optical and power Doppler ultrasound imaging for non-invasive evaluation of arsenic trioxide as a vascular disrupting agent in tumors.

    Science.gov (United States)

    Alhasan, Mustafa K; Liu, Li; Lewis, Matthew A; Magnusson, Jennifer; Mason, Ralph P

    2012-01-01

    Small animal imaging provides diverse methods for evaluating tumor growth and acute response to therapy. This study compared the utility of non-invasive optical and ultrasound imaging to monitor growth of three diverse human tumor xenografts (brain U87-luc-mCherry, mammary MCF7-luc-mCherry, and prostate PC3-luc) growing in nude mice. Bioluminescence imaging (BLI), fluorescence imaging (FLI), and Power Doppler ultrasound (PD US) were then applied to examine acute vascular disruption following administration of arsenic trioxide (ATO).During initial tumor growth, strong correlations were found between manual caliper measured tumor volume and FLI intensity, BLI intensity following luciferin injection, and traditional B-mode US. Administration of ATO to established U87 tumors caused significant vascular shutdown within 2 hrs at all doses in the range 5 to 10 mg/kg in a dose dependant manner, as revealed by depressed bioluminescent light emission. At lower doses substantial recovery was seen within 4 hrs. At 8 mg/kg there was >85% reduction in tumor vascular perfusion, which remained depressed after 6 hrs, but showed some recovery after 24 hrs. Similar response was observed in MCF7 and PC3 tumors. Dynamic BLI and PD US each showed similar duration and percent reductions in tumor blood flow, but FLI showed no significant changes during the first 24 hrs.The results provide further evidence for comparable utility of optical and ultrasound imaging for monitoring tumor growth, More specifically, they confirm the utility of BLI and ultrasound imaging as facile assays of the vascular disruption in solid tumors based on ATO as a model agent.

  16. Clinical utility of eco-color-power Doppler ultrasonography and contrast enhanced magnetic resonance imaging for interpretation and quantification of joint synovitis: a review.

    Science.gov (United States)

    Carotti, Marina; Galeazzi, Vittoria; Catucci, Francesca; Zappia, Marcello; Arrigoni, Francesco; Barile, Antonio; Giovagnoni, Andrea

    2018-01-19

    With the introduction of new biologics such as anti-TNF-alpha antibodies and other therapies in the treatment of inflammatory arthritis, capable of halting joint destruction and functional disability, there are new pressures on diagnostic and prognostic imaging. Early demonstration of pre-erosive inflammatory features and monitoring of the long-term effects of treatment are becoming increasingly important. Early detection of synovitis offers advantages in terms of allowing early instigation of therapy and may allow the identification of those patients displaying more aggressive disease who might benefit from early intervention with expensive DMARD therapy. Advanced imaging techniques such as ultrasound (US) and magnetic resonance imaging (MRI) have focussed on the demonstration and quantification of synovitis and allow early diagnosis of inflammatory arthropathies such as rheumatoid arthritis (RA) and psoriatic arthritis (PsA). Synovitis represents a potential surrogate measure of disease activity that can be monitored using either MRI or US; the techniques have, generally, focused on monitoring synovial volume or quality as assessed by its vascularity. However to achieve these goals, standardisation and validation of US and MRI are required to ensure accurate diagnosis, reproducibility and reliability. Each modality has different strengths and weaknesses and levels of validation. This article aims to increase the awareness of radiologists and rheumatologists about this field and to encourage them to participate and contribute to the ongoing development of these modalities. Without this collaboration, it is unlikely that these modalities will reach their full potential in the field of rheumatological imaging. This review is in two parts. The first part addresses the role of US and colour or power Doppler sonography (PDUS) in the detection and monitoring of synovitis in inflammatory arthropathies. The second part will look at advanced MR imaging and Dynamic contrast

  17. A comparison of radionuclide thyroid angiography, 99mTc-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    International Nuclear Information System (INIS)

    Demirel, Koray; Kapucu, Oezlem; Yuecel, Cem; Oezdemir, Hakan; Ayvaz, Goeksun; Taneri, Ferit

    2003-01-01

    We prospectively studied 43 patients with solitary cold thyroid nodules greater than 1.5 cm in diameter to determine the comparative diagnostic value of radionuclide thyroid angiography (RTA), technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) scintigraphy and power Doppler ultrasonography (PDUS) in the differentiation of benign and malignant thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0, avascular; 1, hypovascular; 2, isovascular; 3, hypervascular. 99m Tc-MIBI uptake in the nodules compared with that in surrounding thyroid tissue was scored for both early and delayed images as follows: 0, cold; 1, decreased; 2, equal; 3, increased. PDUS patterns were classified as nodule vascularisation patterns. The malignancy criteria were set as follows: hypervascular nodule with rapid washout in RTA; complex ring sign with anarchic structure or delta sign in PDUS, and positive retention and increased uptake in the nodule in the early and delayed 99m Tc-MIBI images. These data were compared with the histopathological results. Histology revealed thyroid carcinoma in nine patients (five cases of papillary carcinoma, three of follicular carcinoma and one of medullary carcinoma) and benign conditions in 34 patients (30 cases of nodular goitre, three of lymphocytic thyroiditis and one of follicular adenoma). Sensitivity, specificity and accuracy were, respectively, 0.89, 1.00 and 0.97 for RTA, 1.00, 0.76 and 0.81 for PDUS, and 0.67, 0.91 and 0.86 for 99m Tc-MIBI scintigraphy (when nodules with increased uptake in both the early and the delayed images and a positive retention index were considered as malignant). RTA, 99m Tc-MIBI scintigraphy and PDUS could be helpful in the preoperative assessment of solitary cold thyroid nodules. In this study, RTA was found to be the most accurate and specific method for differentiation of malignant from benign thyroid nodules. (orig.)

  18. Construction and application research of Three-dimensional digital power grid in Southwest China

    Science.gov (United States)

    Zhou, Yang; Zhou, Hong; You, Chuan; Jiang, Li; Xin, Weidong

    2018-01-01

    With the rapid development of Three-dimensional (3D) digital design technology in the field of power grid construction, the data foundation and technical means of 3D digital power grid construction approaches perfection. 3D digital power grid has gradually developed into an important part of power grid construction and management. In view of the complicated geological conditions in Southwest China and the difficulty in power grid construction and management, this paper is based on the data assets of Southwest power grid, and it aims at establishing a 3D digital power grid in Southwest China to provide effective support for power grid construction and operation management. This paper discusses the data architecture, technical architecture and system design and implementation process of the 3D digital power grid construction through teasing the key technology of 3D digital power grid. The application of power grid data assets management, transmission line corridor planning, geological hazards risk assessment, environmental impact assessment in 3D digital power grid are also discussed and analysed.

  19. Three-dimensional Core Design of a Super Fast Reactor with a High Power Density

    International Nuclear Information System (INIS)

    Cao, Liangzhi; Oka, Yoshiaki; Ishiwatari, Yuki; Ikejiri, Satoshi; Ju, Haitao

    2010-01-01

    The SuperCritical Water-cooled Reactor (SCWR) pursues high power density to reduce its capital cost. The fast spectrum SCWR, called a super fast reactor, can be designed with a higher power density than thermal spectrum SCWR. The mechanism of increasing the average power density of the super fast reactor is studied theoretically and numerically. Some key parameters affecting the average power density, including fuel pin outer diameter, fuel pitch, power peaking factor, and the fraction of seed assemblies, are analyzed and optimized to achieve a more compact core. Based on those sensitivity analyses, a compact super fast reactor is successfully designed with an average power density of 294.8 W/cm 3 . The core characteristics are analyzed by using three-dimensional neutronics/thermal-hydraulics coupling method. Numerical results show that all of the design criteria and goals are satisfied

  20. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  1. Crustal geomagnetic field - Two-dimensional intermediate-wavelength spatial power spectra

    Science.gov (United States)

    Mcleod, M. G.

    1983-01-01

    Two-dimensional Fourier spatial power spectra of equivalent magnetization values are presented for a region that includes a large portion of the western United States. The magnetization values were determined by inversion of POGO satellite data, assuming a magnetic crust 40 km thick, and were located on an 11 x 10 array with 300 km grid spacing. The spectra appear to be in good agreement with values of the crustal geomagnetic field spatial power spectra given by McLeod and Coleman (1980) and with the crustal field model given by Serson and Hannaford (1957). The spectra show evidence of noise at low frequencies in the direction along the satellite orbital track (N-S). indicating that for this particular data set additional filtering would probably be desirable. These findings illustrate the value of two-dimensional spatial power spectra both for describing the geomagnetic field statistically and as a guide for diagnosing possible noise sources.

  2. Doppler flowmetry in preeclampsia.

    Science.gov (United States)

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  3. Dimensional control of buttwelding pipe fitting for nuclear power plant Class 1 piping systems

    International Nuclear Information System (INIS)

    Rodabaugh, E.C.; Moore, S.E.; Robinson, J.N.

    1976-11-01

    Dimensional controls of wrought steel buttwelding fittings are examined from the standpoint of design adequacy. A fairly large number of fittings were purchased from different manufacturers. The dimensions of each fitting were measured and correlated along with additional information obtained from the manufacturers in an effort to establish ''standard'' shapes. This information and a critical examination of the present ANSI standards is used to develop a ''Supplementary Standard.'' The Supplementary Standard is intended to provide improved dimensional control and more complete design information for fittings used in Class 1 nuclear power plant piping systems

  4. A three-dimensional breakdown model of SOI lateral power transistors with a circular layout

    International Nuclear Information System (INIS)

    Guo Yufeng; Wang Zhigong; Sheu Gene

    2009-01-01

    This paper presents an analytical three-dimensional breakdown model of SOI lateral power devices with a circular layout. The Poisson equation is solved in cylindrical coordinates to obtain the radial surface potential and electric field distributions for both fully- and partially-depleted drift regions. The breakdown voltages for N + N and P + N junctions are derived and employed to investigate the impact of cathode region curvature. A modified RESURF criterion is proposed to provide a design guideline for optimizing the breakdown voltage and doping concentration in the drift region in three dimensional space. The analytical results agree well with MEDICI simulation results and experimental data from earlier publications. (semiconductor devices)

  5. Mathematical analysis of the dimensional scaling technique for the Schroedinger equation with power-law potentials

    International Nuclear Information System (INIS)

    Ding Zhonghai; Chen, Goong; Lin, Chang-Shou

    2010-01-01

    The dimensional scaling (D-scaling) technique is an innovative asymptotic expansion approach to study the multiparticle systems in molecular quantum mechanics. It enables the calculation of ground and excited state energies of quantum systems without having to solve the Schroedinger equation. In this paper, we present a mathematical analysis of the D-scaling technique for the Schroedinger equation with power-law potentials. By casting the D-scaling technique in an appropriate variational setting and studying the corresponding minimization problem, the D-scaling technique is justified rigorously. A new asymptotic dimensional expansion scheme is introduced to compute asymptotic expansions for ground state energies.

  6. Two-dimensional thermal modeling of power monolithic microwave integrated circuits (MMIC's)

    Science.gov (United States)

    Fan, Mark S.; Christou, Aris; Pecht, Michael G.

    1992-01-01

    Numerical simulations of the two-dimensional temperature distributions for a typical GaAs MMIC circuit are conducted, aiming at understanding the heat conduction process of the circuit chip and providing temperature information for device reliability analysis. The method used is to solve the two-dimensional heat conduction equation with a control-volume-based finite difference scheme. In particular, the effects of the power dissipation and the ambient temperature are examined, and the criterion for the worst operating environment is discussed in terms of the allowed highest device junction temperature.

  7. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  8. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  9. Abatacept reduces disease activity and ultrasound power Doppler in ACPA-negative undifferentiated arthritis: a proof-of-concept clinical and imaging study.

    Science.gov (United States)

    Buch, Maya H; Hensor, Elizabeth M A; Rakieh, Chadi; Freeston, Jane E; Middleton, Edward; Horton, Sarah; Das, Sudipto; Peterfy, Charles; Tan, Ai Lyn; Wakefield, Richard J; Emery, Paul

    2017-01-01

    No proven treatment exists for ACPA-negative undifferentiated arthritis (UA). The aim of this study was to evaluate whether abatacept is effective in treating poor prognosis, ACPA-negative UA, including its effect on power Doppler on US (PDUS). A proof-of-concept, open-label, prospective study of 20 patients with DMARD-naïve, ACPA-negative UA (⩾2 joint synovitis) and PDUS ⩾ 1 with clinical and 20-joint US (grey scale/PDUS) assessments at baseline, 6, 12, 18 and 24 months. All patients received 12 months of abatacept (monotherapy for minimum first 6 months). The primary end point was a composite of the proportion of patients that at 6 months achieved DAS44 remission, a maximum of one swollen joint for at least 3 consecutive months and no radiographic progression (over 0-12 months). Twenty of the 23 patients screened were enrolled [14 female; mean (sd) age 53.4 (11.2) years, symptom duration 7.5 (0.9) months]. Two (10%) achieved the composite primary end point. A reduction in the mean (sd) DAS44 was observed from a baseline value of 2.66 (0.77) to 2.01 (0.81) at 6 months and to 1.78 (0.95) at 12 months. The DAS44 remission rates were 6/20 (30%; 95% CI: 15, 51%) at 6 months and 8/20 (40%; 95% CI: 22, 62%) at 12 months. A striking decrease in the median (interquartile range; IQR) total PDUS score was noted from 10 (4-23) at baseline to 3 (2-12) and 3 (0-5) at 6 and 12 months, respectively. This report is a first in potentially identifying an effective therapy, abatacept monotherapy, for poor-prognosis, ACPA-negative UA, supported by a clear reduction in PDUS. These data justify evaluation in a controlled study. © The Author 2016. Published by Oxford University Press on behalf of the British Society for Rheumatology. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. A comparison of radionuclide thyroid angiography, {sup 99m}Tc-MIBI scintigraphy and power Doppler ultrasonography in the differential diagnosis of solitary cold thyroid nodules

    Energy Technology Data Exchange (ETDEWEB)

    Demirel, Koray; Kapucu, Oezlem [Department of Nuclear Medicine, Gazi University School of Medicine, Ankara (Turkey); Yuecel, Cem; Oezdemir, Hakan [Department of Radiology, Gazi University School of Medicine, Ankara (Turkey); Ayvaz, Goeksun [Department of Endocrinology and Metabolic Diseases, Gazi University School of Medicine, Ankara (Turkey); Taneri, Ferit [Department of Surgery, Gazi University School of Medicine, Ankara (Turkey)

    2003-05-01

    We prospectively studied 43 patients with solitary cold thyroid nodules greater than 1.5 cm in diameter to determine the comparative diagnostic value of radionuclide thyroid angiography (RTA), technetium-99m methoxyisobutylisonitrile ({sup 99m}Tc-MIBI) scintigraphy and power Doppler ultrasonography (PDUS) in the differentiation of benign and malignant thyroid nodules. Perfusion of the nodules in RTA was compared with the perfusion in the surrounding normal thyroid tissue and classified as follows: 0, avascular; 1, hypovascular; 2, isovascular; 3, hypervascular. {sup 99m}Tc-MIBI uptake in the nodules compared with that in surrounding thyroid tissue was scored for both early and delayed images as follows: 0, cold; 1, decreased; 2, equal; 3, increased. PDUS patterns were classified as nodule vascularisation patterns. The malignancy criteria were set as follows: hypervascular nodule with rapid washout in RTA; complex ring sign with anarchic structure or delta sign in PDUS, and positive retention and increased uptake in the nodule in the early and delayed {sup 99m}Tc-MIBI images. These data were compared with the histopathological results. Histology revealed thyroid carcinoma in nine patients (five cases of papillary carcinoma, three of follicular carcinoma and one of medullary carcinoma) and benign conditions in 34 patients (30 cases of nodular goitre, three of lymphocytic thyroiditis and one of follicular adenoma). Sensitivity, specificity and accuracy were, respectively, 0.89, 1.00 and 0.97 for RTA, 1.00, 0.76 and 0.81 for PDUS, and 0.67, 0.91 and 0.86 for {sup 99m}Tc-MIBI scintigraphy (when nodules with increased uptake in both the early and the delayed images and a positive retention index were considered as malignant). RTA, {sup 99m}Tc-MIBI scintigraphy and PDUS could be helpful in the preoperative assessment of solitary cold thyroid nodules. In this study, RTA was found to be the most accurate and specific method for differentiation of malignant from benign

  11. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...

  12. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  13. The Cognitive Doppler.

    Science.gov (United States)

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  14. Noncoherent Doppler tracking: first flight results

    Science.gov (United States)

    DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.

    2005-01-01

    Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.

  15. Enhanced thermoelectric power in two-dimensional transition metal dichalcogenide monolayers

    KAUST Repository

    Pu, Jiang

    2016-07-27

    The carrier-density-dependent conductance and thermoelectric properties of large-area MoS2 and WSe2 monolayers are simultaneously investigated using the electrolyte gating method. The sign of the thermoelectric power changes across the transistor off-state in the ambipolar WSe2 transistor as the majority carrier density switches from electron to hole. The thermopower and thermoelectric power factor of monolayer samples are one order of magnitude larger than that of bulk materials, and their carrier-density dependences exhibit a quantitative agreement with the semiclassical Mott relation based on the two-dimensional energy band structure, concluding the thermoelectric properties are enhanced by the low-dimensional effect.

  16. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  17. Approximation model of three-dimensional power distribution in boiling water reactor using neural networks

    International Nuclear Information System (INIS)

    Kobayashi, Yoko; Aiyoshi, Eitaro

    2001-01-01

    Fast and accurate prediction of three-dimensional (3D) power distribution is essential in a boiling water reactor (BWR). The prediction method of 3D power distribution in BWR is developed using the neural network. Application of the neural network starts with selecting the learning algorithm. In the proposed method, we use the learning algorithms based on a class of Quasi-Newton optimization techniques called Self-Scaling Variable Metric (SSVM) methods. Prediction studies were done for a core of actual BWR plant with octant symmetry. Compared to classical Quasi-Newton methods, it is shown that the SSVM method reduces the number of iterations in the learning mode. The results of prediction demonstrate that the neural network can predict 3D power distribution of BWR reasonably well. The proposed method will be very useful for BWR loading pattern optimization problems where 3D power distribution for a huge number of loading patterns (LPs) must be performed. (author)

  18. Two-dimensional AXUV-based radiated power density diagnostics on NSTX-U.

    Science.gov (United States)

    Faust, I; Delgado-Aparicio, L; Bell, R E; Tritz, K; Diallo, A; Gerhardt, S P; LeBlanc, B; Kozub, T A; Parker, R R; Stratton, B C

    2014-11-01

    A new set of radiated-power-density diagnostics for the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak have been designed to measure the two-dimensional poloidal structure of the total photon emissivity profile in order to perform power balance, impurity transport, and magnetohydrodynamic studies. Multiple AXUV-diode based pinhole cameras will be installed in the same toroidal angle at various poloidal locations. The local emissivity will be obtained from several types of tomographic reconstructions. The layout and response expected for the new radially viewing poloidal arrays will be shown for different impurity concentrations to characterize the diagnostic sensitivity. The radiated power profile inverted from the array data will also be used for estimates of power losses during transitions from various divertor configurations in NSTX-U. The effect of in-out and top/bottom asymmetries in the core radiation from high-Z impurities will be addressed.

  19. Two-dimensional AXUV-based radiated power density diagnostics on NSTX-Ua)

    Science.gov (United States)

    Faust, I.; Delgado-Aparicio, L.; Bell, R. E.; Tritz, K.; Diallo, A.; Gerhardt, S. P.; LeBlanc, B.; Kozub, T. A.; Parker, R. R.; Stratton, B. C.

    2014-11-01

    A new set of radiated-power-density diagnostics for the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak have been designed to measure the two-dimensional poloidal structure of the total photon emissivity profile in order to perform power balance, impurity transport, and magnetohydrodynamic studies. Multiple AXUV-diode based pinhole cameras will be installed in the same toroidal angle at various poloidal locations. The local emissivity will be obtained from several types of tomographic reconstructions. The layout and response expected for the new radially viewing poloidal arrays will be shown for different impurity concentrations to characterize the diagnostic sensitivity. The radiated power profile inverted from the array data will also be used for estimates of power losses during transitions from various divertor configurations in NSTX-U. The effect of in-out and top/bottom asymmetries in the core radiation from high-Z impurities will be addressed.

  20. Two-dimensional AXUV-based radiated power density diagnostics on NSTX-U

    Energy Technology Data Exchange (ETDEWEB)

    Faust, I.; Parker, R. R. [MIT - Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Delgado-Aparicio, L.; Bell, R. E.; Diallo, A.; Gerhardt, S. P.; LeBlanc, B.; Kozub, T. A. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540 (United States); Tritz, K. [The Johns Hopkins University, Baltimore, Maryland 21209 (United States); Stratton, B. C. [MIT - Plasma Science and Fusion Center, Cambridge, Massachusetts 02139 (United States); Princeton Plasma Physics Laboratory, Princeton, New Jersey 08540 (United States)

    2014-11-15

    A new set of radiated-power-density diagnostics for the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak have been designed to measure the two-dimensional poloidal structure of the total photon emissivity profile in order to perform power balance, impurity transport, and magnetohydrodynamic studies. Multiple AXUV-diode based pinhole cameras will be installed in the same toroidal angle at various poloidal locations. The local emissivity will be obtained from several types of tomographic reconstructions. The layout and response expected for the new radially viewing poloidal arrays will be shown for different impurity concentrations to characterize the diagnostic sensitivity. The radiated power profile inverted from the array data will also be used for estimates of power losses during transitions from various divertor configurations in NSTX-U. The effect of in-out and top/bottom asymmetries in the core radiation from high-Z impurities will be addressed.

  1. Two-dimensional AXUV-based radiated power density diagnostics on NSTX-U

    International Nuclear Information System (INIS)

    Faust, I.; Parker, R. R.; Delgado-Aparicio, L.; Bell, R. E.; Diallo, A.; Gerhardt, S. P.; LeBlanc, B.; Kozub, T. A.; Tritz, K.; Stratton, B. C.

    2014-01-01

    A new set of radiated-power-density diagnostics for the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak have been designed to measure the two-dimensional poloidal structure of the total photon emissivity profile in order to perform power balance, impurity transport, and magnetohydrodynamic studies. Multiple AXUV-diode based pinhole cameras will be installed in the same toroidal angle at various poloidal locations. The local emissivity will be obtained from several types of tomographic reconstructions. The layout and response expected for the new radially viewing poloidal arrays will be shown for different impurity concentrations to characterize the diagnostic sensitivity. The radiated power profile inverted from the array data will also be used for estimates of power losses during transitions from various divertor configurations in NSTX-U. The effect of in-out and top/bottom asymmetries in the core radiation from high-Z impurities will be addressed

  2. Three-dimensional electromagnetic model of the pulsed-power Z-pinch accelerator

    Directory of Open Access Journals (Sweden)

    D. V. Rose

    2010-01-01

    Full Text Available A three-dimensional, fully electromagnetic model of the principal pulsed-power components of the 26-MA ZR accelerator [D. H. McDaniel et al., in Proceedings of the 5th International Conference on Dense Z-Pinches (AIP, New York, 2002, p. 23] has been developed. This large-scale simulation model tracks the evolution of electromagnetic waves through the accelerator’s intermediate-storage capacitors, laser-triggered gas switches, pulse-forming lines, water switches, triplate transmission lines, and water convolute to the vacuum insulator stack. The insulator-stack electrodes are coupled to a transmission-line circuit model of the four-level magnetically insulated vacuum-transmission-line section and double-post-hole convolute. The vacuum-section circuit model is terminated by a one-dimensional self-consistent dynamic model of an imploding z-pinch load. The simulation results are compared with electrical measurements made throughout the ZR accelerator, and are in good agreement with the data, especially for times until peak load power. This modeling effort demonstrates that 3D electromagnetic models of large-scale, multiple-module, pulsed-power accelerators are now computationally tractable. This, in turn, presents new opportunities for simulating the operation of existing pulsed-power systems used in a variety of high-energy-density-physics and radiographic applications, as well as even higher-power next-generation accelerators before they are constructed.

  3. Power1D: a Python toolbox for numerical power estimates in experiments involving one-dimensional continua

    Directory of Open Access Journals (Sweden)

    Todd C. Pataky

    2017-07-01

    Full Text Available The unit of experimental measurement in a variety of scientific applications is the one-dimensional (1D continuum: a dependent variable whose value is measured repeatedly, often at regular intervals, in time or space. A variety of software packages exist for computing continuum-level descriptive statistics and also for conducting continuum-level hypothesis testing, but very few offer power computing capabilities, where ‘power’ is the probability that an experiment will detect a true continuum signal given experimental noise. Moreover, no software package yet exists for arbitrary continuum-level signal/noise modeling. This paper describes a package called power1d which implements (a two analytical 1D power solutions based on random field theory (RFT and (b a high-level framework for computational power analysis using arbitrary continuum-level signal/noise modeling. First power1d’s two RFT-based analytical solutions are numerically validated using its random continuum generators. Second arbitrary signal/noise modeling is demonstrated to show how power1d can be used for flexible modeling well beyond the assumptions of RFT-based analytical solutions. Its computational demands are non-excessive, requiring on the order of only 30 s to execute on standard desktop computers, but with approximate solutions available much more rapidly. Its broad signal/noise modeling capabilities along with relatively rapid computations imply that power1d may be a useful tool for guiding experimentation involving multiple measurements of similar 1D continua, and in particular to ensure that an adequate number of measurements is made to detect assumed continuum signals.

  4. A micro-Doppler sonar for acoustic surveillance in sensor networks

    Science.gov (United States)

    Zhang, Zhaonian

    Wireless sensor networks have been employed in a wide variety of applications, despite the limited energy and communication resources at each sensor node. Low power custom VLSI chips implementing passive acoustic sensing algorithms have been successfully integrated into an acoustic surveillance unit and demonstrated for detection and location of sound sources. In this dissertation, I explore active and passive acoustic sensing techniques, signal processing and classification algorithms for detection and classification in a multinodal sensor network environment. I will present the design and characterization of a continuous-wave micro-Doppler sonar to image objects with articulated moving components. As an example application for this system, we use it to image gaits of humans and four-legged animals. I will present the micro-Doppler gait signatures of a walking person, a dog and a horse. I will discuss the resolution and range of this micro-Doppler sonar and use experimental results to support the theoretical analyses. In order to reduce the data rate and make the system amenable to wireless sensor networks, I will present a second micro-Doppler sonar that uses bandpass sampling for data acquisition. Speech recognition algorithms are explored for biometric identifications from one's gait, and I will present and compare the classification performance of the two systems. The acoustic micro-Doppler sonar design and biometric identification results are the first in the field as the previous work used either video camera or microwave technology. I will also review bearing estimation algorithms and present results of applying these algorithms for bearing estimation and tracking of moving vehicles. Another major source of the power consumption at each sensor node is the wireless interface. To address the need of low power communications in a wireless sensor network, I will also discuss the design and implementation of ultra wideband transmitters in a three dimensional

  5. Doppler radar flowmeter

    Science.gov (United States)

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  6. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  7. Molecules cooled below the Doppler limit

    Science.gov (United States)

    Truppe, S.; Williams, H. J.; Hambach, M.; Caldwell, L.; Fitch, N. J.; Hinds, E. A.; Sauer, B. E.; Tarbutt, M. R.

    2017-12-01

    Magneto-optical trapping and sub-Doppler cooling have been essential to most experiments with quantum degenerate gases, optical lattices, atomic fountains and many other applications. A broad set of new applications await ultracold molecules, and the extension of laser cooling to molecules has begun. A magneto-optical trap (MOT) has been demonstrated for a single molecular species, SrF, but the sub-Doppler temperatures required for many applications have not yet been reached. Here we demonstrate a MOT of a second species, CaF, and we show how to cool these molecules to 50 μK, well below the Doppler limit, using a three-dimensional optical molasses. These ultracold molecules could be loaded into optical tweezers to trap arbitrary arrays for quantum simulation, launched into a molecular fountain for testing fundamental physics, and used to study collisions and chemistry between atoms and molecules at ultracold temperatures.

  8. Craig's XY distribution and the statistics of Lagrangian power in two-dimensional turbulence

    Science.gov (United States)

    Bandi, Mahesh M.; Connaughton, Colm

    2008-03-01

    We examine the probability distribution function (PDF) of the energy injection rate (power) in numerical simulations of stationary two-dimensional (2D) turbulence in the Lagrangian frame. The simulation is designed to mimic an electromagnetically driven fluid layer, a well-documented system for generating 2D turbulence in the laboratory. In our simulations, the forcing and velocity fields are close to Gaussian. On the other hand, the measured PDF of injected power is very sharply peaked at zero, suggestive of a singularity there, with tails which are exponential but asymmetric. Large positive fluctuations are more probable than large negative fluctuations. It is this asymmetry of the tails which leads to a net positive mean value for the energy input despite the most probable value being zero. The main features of the power distribution are well described by Craig’s XY distribution for the PDF of the product of two correlated normal variables. We show that the power distribution should exhibit a logarithmic singularity at zero and decay exponentially for large absolute values of the power. We calculate the asymptotic behavior and express the asymmetry of the tails in terms of the correlation coefficient of the force and velocity. We compare the measured PDFs with the theoretical calculations and briefly discuss how the power PDF might change with other forcing mechanisms.

  9. Maximal locality and predictive power in higher-dimensional, compactified field theories

    International Nuclear Information System (INIS)

    Kubo, Jisuke; Nunami, Masanori

    2004-01-01

    To realize maximal locality in a trivial field theory, we maximize the ultraviolet cutoff of the theory by fine tuning the infrared values of the parameters. This optimization procedure is applied to the scalar theory in D + 1 dimensional (D ≥ 4) with one extra dimension compactified on a circle of radius R. The optimized, infrared values of the parameters are then compared with the corresponding ones of the uncompactified theory in D dimensions, which is assumed to be the low-energy effective theory. We find that these values approximately agree with each other as long as R -1 > approx sM is satisfied, where s ≅ 10, 50, 50, 100 for D = 4,5,6,7, and M is a typical scale of the D-dimensional theory. This result supports the previously made claim that the maximization of the ultraviolet cutoff in a nonrenormalizable field theory can give the theory more predictive power. (author)

  10. MP3 compression of Doppler ultrasound signals.

    Science.gov (United States)

    Poepping, Tamie L; Gill, Jeremy; Fenster, Aaron; Holdsworth, David W

    2003-01-01

    The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals. Copyright 2003 World Federation for Ultrasound in Medicine & Biology

  11. Dimensional stability of some Fe-Ni-Cr alloys used in nuclear power generation

    International Nuclear Information System (INIS)

    Marucco, A.; Nath, B.

    1983-01-01

    The dimensional stability of four materials used in the nuclear power industry, viz Nimonic PE16, 20Cr-25Ni steel, Alloy 600 and Inconel 690, have been studied using X-ray diffractometry, electrical resistivity and thin foil microscopic techniques. Appreciable reductions in lattice parameters of these alloys occur on exposure to temperatures of 823 deg K and below. An order-disorder transformation has been found to be responsible for the observed behaviour. The transformation kinetics, associated microstructural changes and the implications for the usage of these materials are discussed. (author)

  12. Thermoelectric power and topological transitions in quasi-two-dimensional electronic systems

    International Nuclear Information System (INIS)

    Blanter, Ya.M.; Pantsulaya, A.V.; Varlamov, A.A.

    1991-05-01

    Electron-impurity relaxation time and the thermoelectric power (TEP) of quasi-two-dimensional electron gas are calculated. Two cases are discussed: the isotropic spectrum and the electronic topological transition (ETT) of the ''neck-breaking'' type. Methods of thermal diagramatic technique are used for the calculation. It is found that the TEP in the vicinity of the ETT greatly exceeds its background value. The results of experimental investigations of the TEP in the metal-oxide-semiconductor structures are compared with the predictions of the proposed theory. (author). 17 refs, 5 figs

  13. Wind Farm Power Forecasting for Less Than an Hour Using Multi Dimensional Models

    DEFF Research Database (Denmark)

    Knudsen, Torben; Bak, Thomas; Jensen, Tom Nørgaard

    2018-01-01

    The paper focus on prediction of wind farm power for horizons of 0-10 minutes and not more than one hour using statistical methods. These short term predictions are relevant for both transmission system operators, wind farm operators and traders. Previous research indicates that for short time ho...... the prediction error variance estimate compared to the persistence method. We also present convincing examples showing that the predictions follow the wind farm power over a window of an hour.......The paper focus on prediction of wind farm power for horizons of 0-10 minutes and not more than one hour using statistical methods. These short term predictions are relevant for both transmission system operators, wind farm operators and traders. Previous research indicates that for short time...... horizons the persistence method performs as well as more complex methods. However, these results are based on accumulated power for an entire wind farm. The contribution in this paper is to develop multi-dimensional linear methods based on measurements of power or wind speed from individual wind turbine...

  14. High thermoelectric power factor in two-dimensional crystals of Mo S2

    Science.gov (United States)

    Hippalgaonkar, Kedar; Wang, Ying; Ye, Yu; Qiu, Diana Y.; Zhu, Hanyu; Wang, Yuan; Moore, Joel; Louie, Steven G.; Zhang, Xiang

    2017-03-01

    The quest for high-efficiency heat-to-electricity conversion has been one of the major driving forces toward renewable energy production for the future. Efficient thermoelectric devices require high voltage generation from a temperature gradient and a large electrical conductivity while maintaining a low thermal conductivity. For a given thermal conductivity and temperature, the thermoelectric power factor is determined by the electronic structure of the material. Low dimensionality (1D and 2D) opens new routes to a high power factor due to the unique density of states (DOS) of confined electrons and holes. The 2D transition metal dichalcogenide (TMDC) semiconductors represent a new class of thermoelectric materials not only due to such confinement effects but especially due to their large effective masses and valley degeneracies. Here, we report a power factor of Mo S2 as large as 8.5 mW m-1K-2 at room temperature, which is among the highest measured in traditional, gapped thermoelectric materials. To obtain these high power factors, we perform thermoelectric measurements on few-layer Mo S2 in the metallic regime, which allows us to access the 2D DOS near the conduction band edge and exploit the effect of 2D confinement on electron scattering rates, resulting in a large Seebeck coefficient. The demonstrated high, electronically modulated power factor in 2D TMDCs holds promise for efficient thermoelectric energy conversion.

  15. Analysis of Doppler effect with JAERI-Fast set

    International Nuclear Information System (INIS)

    Takano, Hideki; Matsui, Yasushi.

    1977-07-01

    Temperature dependence of group cross sections in the JAERI-Fast set versions I, IR, II and IIR has been tested from the analysis of Doppler experiments performed with two different methods. One is Doppler reactivity measurement for the whole core of SEFOR assembly, and the other sample Doppler reactivity measurement for natural UO 2 in FCA assemblies V-1, V-2, VI-1 and VI-2, ZPR-6-7, ZPR-3-47, and ZPPR-2 and 3. Doppler effects were calculated with one- and two-dimensional diffusion 1-st order perturbation code DOPP2D. The results calculated with the JAERI-Fast set versions II and IIR are in good agreement with the experimental ones. In these calculation, resonance heterogeneity effect, stainless-stell buffer effect and plate heterogeneity effect are considered, and these effects contribute significantly to Doppler effect. (auth.)

  16. Beam alignment based on two-dimensional power spectral density of a near-field image.

    Science.gov (United States)

    Wang, Shenzhen; Yuan, Qiang; Zeng, Fa; Zhang, Xin; Zhao, Junpu; Li, Kehong; Zhang, Xiaolu; Xue, Qiao; Yang, Ying; Dai, Wanjun; Zhou, Wei; Wang, Yuanchen; Zheng, Kuixing; Su, Jingqin; Hu, Dongxia; Zhu, Qihua

    2017-10-30

    Beam alignment is crucial to high-power laser facilities and is used to adjust the laser beams quickly and accurately to meet stringent requirements of pointing and centering. In this paper, a novel alignment method is presented, which employs data processing of the two-dimensional power spectral density (2D-PSD) for a near-field image and resolves the beam pointing error relative to the spatial filter pinhole directly. Combining this with a near-field fiducial mark, the operation of beam alignment is achieved. It is experimentally demonstrated that this scheme realizes a far-field alignment precision of approximately 3% of the pinhole size. This scheme adopts only one near-field camera to construct the alignment system, which provides a simple, efficient, and low-cost way to align lasers.

  17. Laser ray tracing and power deposition on an unstructured three-dimensional grid

    International Nuclear Information System (INIS)

    Kaiser, Thomas B.

    2000-01-01

    A scheme is presented for laser beam evolution and power deposition on three-dimensional unstructured grids composed of hexahedra, prisms, pyramids, and tetrahedra. The geometrical-optics approximation to the electromagnetic wave equation is used to follow propagation of a collection of discrete rays used to represent the beam(s). Ray trajectory equations are integrated using a method that is second order in time, exact for a constant electron-density gradient, and capable of dealing with density discontinuities that arise in certain hydrodynamics formulations. Power deposition by inverse-bremsstrahlung is modeled with a scheme based on Gaussian quadrature to accommodate a deposition rate whose spatial variation is highly nonuniform. Comparisons with analytic results are given for a density ramp in three dimensions, and a ''quadratic-well'' density trough in two dimensions. (c) 2000 The American Physical Society

  18. Measurement of the stopping power of water for carbon ions in the energy range of 1 MeV-6 MeV using the inverted Doppler-shift attenuation method

    Energy Technology Data Exchange (ETDEWEB)

    Rahm, Johannes Martin

    2016-10-31

    Cancer therapy using carbon ions has gained increasing interest in the last decade due to its advantageous dose distributions. For the dosimetry and treatment planning, the accurate knowledge of the stopping power of water for carbon ions is of crucial importance. In the high energy region, the stopping power can be calculated rather accurately by means of the Bethe-Bloch formula. In the case of projectile velocities comparable to those of the valence electrons of the target, these calculations are subject to large uncertainties. There exist no experimental data for the stopping power of water for projectile energies prevailing in the so-called Bragg peak region. The currently available stopping power data for water are derived from measurements in water vapour or D{sub 2}O ice and, hence, neglect the dependence on the state of aggregation. The stopping power of water for charged particles is of high interest not only for practical applications but also to consider how physical and chemical state of the target influence the collisional energy transfer. For the measurement of the stopping power of water, the inverted Doppler-shift attenuation method was used in this work. This method has the advantage that the projectile itself is not needed to be detected and can be slowed down entirely in the target. In this method, the stopping power is determined from the Doppler-shift of the gamma-quanta emitted by projectiles during their slow down. This experiment can be performed at atmospheric pressure and consequently, the stopping power of water can be measured in its real physiological condition. In this work, the stopping power of water for carbon ions was measured for the first time in the energy range between 1 MeV and 6 MeV covering the kinetic energies of carbon ions in the Bragg peak region. The experimental method is presented in detail along with the design of the apparatus and of the data acquisition system. A comprehensive analysis of instrumental effects

  19. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  20. Linear and nonlinear light propagations in a Doppler-broadened medium via electromagnetically induced transparency

    International Nuclear Information System (INIS)

    Li Liang; Huang Guoxiang

    2010-01-01

    We present a systematic theoretical study to deal with linear and nonlinear light propagations in a Doppler-broadened three-level Λ system via electromagnetically induced transparency (EIT), with incoherent population exchange between two lower energy levels taken into account. Through a careful analysis of base state and linear excitation, we show that the EIT condition of the system is given by |Ω c | 2 γ 31 >>2γ 21 Δω D 2 , where Ω c is half the Rabi frequency of the control field, Δω D is the Doppler width, and γ jl is the decay rate of the coherence between states |j> and |l>. Under this condition, the effect of incoherent population exchange is insignificant, while dephasing dominates the decoherence of the system. This condition also ensures the validity of the weak nonlinear perturbation theory used in this work for solving the Maxwell-Bloch equations with inhomogeneous broadening. We then investigate the nonlinear propagation of the probe field and show that it is possible to form temporal optical solitons in the Doppler-broadened medium. Such solitons have ultraslow propagating velocity and can be generated in very low light power. The possibility of realizing (1+1)-dimensional and (2+1)-dimensional spatial optical solitons in the adiabatic regime of the system is also discussed.

  1. Effect of local automatic control rods on three-dimensional calculations of the power distribution in an RBMK

    International Nuclear Information System (INIS)

    Pogosbekyan, L.R.; Lysov, D.A.; Bronitskii, L.L.

    1993-01-01

    Numerical simulators and information systems that support nuclear reactor operators must have fast models to estimate how fuel reloads and control rod displacement affect neutron and power distributions in the core. The consequences of reloads and control rod displacement cannot be evaluated correctly without considering local automatic control-rod operations in maintaining the radial power distribution. Fast three-dimensional models to estimate the effects of reloads and displacement of the control and safety rods have already been examined. I.V. Zonov et al. used the following assumptions in their calculational model: (1) the full-scale problem could be reduced a three-dimensional fragment of a locally perturbed core, and (2) the boundary conditions of the fragment and its total power were constant. The last assumption considers approximately how local automatic control rods stabilize the radial power distribution, but three dimensional calculations with these rods are not considered. These assumptions were introduced to obtain high computational speed. I.L. Bronitskii et al. considered in more detail how moving the local automatic control rods affect the power dimensional in the three-dimensional fragment, because, with on-line monitoring of the reload process, information on control rod positions is periodically renewed, and the calculations are done in real time. This model to predict the three-dimensional power distribution to (1) do a preliminary reload analysis, and (2) prepare the core for reloading did not consider the effect of perturbations from the local automatic control rods. Here we examine a model of a stationary neutron distribution. On one hand it gives results in an acceptable computation time; on the other it is a full-scale three-dimensional model and considers how local automatic control rods affect both the radial and axial power distribution

  2. The phenomenon of Doppler

    International Nuclear Information System (INIS)

    Stoll, I.; Seidlerova, I.; Schwippel, J.; Poss, O.; Solc, M.

    1992-01-01

    The book is devoted to the life and work of Christian Doppler and particularly to his links to Prague and to the Slovak town of Banska Stiavnica. Many historical facts concerning Doppler's activities as well as the history of physics and astronomy are collected. Information is also presented about the Czech Technical University, the Society of Czechoslovak Mathematicians and Physicists, the Czechoslovak Astronomical Society, the Czechoslovak Spectroscopic Society and the Czechoslovak Society for the History of Science and Technology. The publication is amply supplemented with historical pictorial material (M.D.). 92 figs., 82 refs

  3. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  4. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  5. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  6. Stopping powers from the inverted doppler shift attenuation method: Z-oscillations; Bragg's rule or chemical effects; solid and liquid state effects

    International Nuclear Information System (INIS)

    Pietsch, W.; Hauser, U.; Neuwirth, W.

    1976-01-01

    With the 'Inverted Doppler Shift Attenuation (IDSA)' method stopping cross sections for swift ions can be measured with an accuracy of about 1%. Here results are reported with lithium and carbon projectiles in very different stopping materials. It turns out that the stopping cross section around Bohr's velocity is linearly dependent on the velocity. Stopping cross sections of elements show the expected Z 2 -oscillations. With compound targets strong deviations from Bragg's rule were found which means that the stopping cross section is influenced by the chemical bonding. In electrolytic solutions effects due to ion-dipole interactions can be observed. These phenomena demonstrate the strong sensitivity of electronic stopping cross sections on the specific distribution of the outer electrons of the target atoms. Further Lindhard's formula has been modified which gives a good description of this influence. (Auth.)

  7. One-dimensional power spectrum and neutrino mass in the spectra of BOSS

    International Nuclear Information System (INIS)

    Borde, Arnaud

    2014-01-01

    The framework of the studies presented in this thesis is the one-dimensional power spectrum of the transmitted flux in the Lyman-alpha forests. The Lyman-alpha forest is an absorption pattern seen in the spectra of high redshift quasars corresponding to the absorption of the quasar light by the hydrogen clouds along the line of sight. It is a powerful cosmological tool as it probes relatively small scales, of the order of a few Mpc. It is also sensible to small non-linear effects such as the one induced by massive neutrinos. First, we have developed two independent methods to measure the one-dimensional power spectrum of the transmitted flux in the Lyman-alpha forest. The first method is based on a Fourier transform, and the second on a maximum likelihood estimator. The two methods are independent and have different systematic uncertainties. The determination of the noise level in the data spectra was subject to a novel treatment, because of its significant impact on the derived power spectrum. We applied the two methods to 13,821 quasar spectra from SDSS-III/BOSS DR9 selected from a larger sample of over 60,000 spectra on the basis of their high quality, large signal-to-noise ratio, and good spectral resolution. The power spectra measured using either approach are in good agreement over all twelve redshift bins from =2.2 to =4.4, and scales from 0.001 (km/s)"-"1 to 0.02 (km/s)"-"1. We carefully determined the methodological and instrumental systematic uncertainties of our measurements. Then, we present a suite of cosmological N-body simulations with cold dark matter, baryons and neutrinos aiming at modeling the low-density regions of the IGM as probed by the Lyman-alpha forests at high redshift. The simulations are designed to match the requirements imposed by the quality of BOSS and eBOSS data. They are made using either 768"3 or 192"3 particles of each type, spanning volumes ranging from (25 Mpc/h)"3 for high-resolution simulations to (100 Mpc/h)"3 for large

  8. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  9. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  10. Doppler-musical instrument

    International Nuclear Information System (INIS)

    Sato, T.J.; Watanabe, N.

    2001-01-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 μeV, even when the ultra-high energy resolution of ΔE∼0.03 μeV is attained. (author)

  11. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  12. First operation of a powerful FEL with two-dimensional distributed feedback

    CERN Document Server

    Agarin, N V; Bobylev, V B; Ginzburg, N S; Ivanenko, V G; Kalinin, P V; Kuznetsov, S A; Peskov, N Yu; Sergeev, A S; Sinitsky, S L; Stepanov, V D

    2000-01-01

    A W-band (75 GHz) FEL of planar geometry driven by a sheet electron beam was realised using the pulse accelerator ELMI (0.8 MeV/3 kA/5 mu s). To provide the spatial coherence of radiation from different parts of the electron beam with a cross-section of 0.4x12 cm two-dimensional distributed feedback systems have been employed using a 2-D Bragg resonator of planar geometry. The resonator consisted of two 2-D Bragg reflectors separated by a regular waveguide section. The total energy in the microwave pulse of microsecond duration was 100 J corresponding to a power of approx 100 MW. The main component of the FEL radiation spectrum was at 75 GHz that corresponded to the zone of effective Bragg reflection found from 'cold' microwave testing of the resonator. The experimental data compared well with the results of theoretical analysis.

  13. Two-dimensional semi-analytic nodal method for multigroup pin power reconstruction

    International Nuclear Information System (INIS)

    Seung Gyou, Baek; Han Gyu, Joo; Un Chul, Lee

    2007-01-01

    A pin power reconstruction method applicable to multigroup problems involving square fuel assemblies is presented. The method is based on a two-dimensional semi-analytic nodal solution which consists of eight exponential terms and 13 polynomial terms. The 13 polynomial terms represent the particular solution obtained under the condition of a 2-dimensional 13 term source expansion. In order to achieve better approximation of the source distribution, the least square fitting method is employed. The 8 exponential terms represent a part of the analytically obtained homogeneous solution and the 8 coefficients are determined by imposing constraints on the 4 surface average currents and 4 corner point fluxes. The surface average currents determined from a transverse-integrated nodal solution are used directly whereas the corner point fluxes are determined during the course of the reconstruction by employing an iterative scheme that would realize the corner point balance condition. The outgoing current based corner point flux determination scheme is newly introduced. The accuracy of the proposed method is demonstrated with the L336C5 benchmark problem. (authors)

  14. Analytical one-dimensional frequency response and stability model for PWR nuclear power plants

    International Nuclear Information System (INIS)

    Hoeld, A.

    1975-01-01

    A dynamic model for PWR nuclear power plants is presented. The plant is assumed to consist of one-dimensional single-channel core, a counterflow once-through steam generator (represented by two nodes according to the nonboiling and boiling region) and the necessary connection coolant lines. The model describes analytically the frequency response behaviour of important parameters of such a plant with respect to perturbations in reactivity, subcooling or mass flow (both at the entrances to the reactor core and/or the secondary steam generator side), the perturbations in steam load or system pressure (on the secondary side of the steam generator). From corresponding 'open' loop considerations it can then be concluded - by applying the Nyquist criterion - upon the degree of the stability behaviour of the underlying system. Based on this theoretical model, a computer code named ADYPMO has been established. From the knowledge of the frequency response behaviour of such a system, the corresponding transient behaviour with respect to a stepwise or any other perturbation signal can also be calculated by applying an appropriate retransformation method, e.g. by using digital code FRETI. To demonstrate this procedure, a transient experimental curve measured during the pre-operational test period at the PWR nuclear power plant KKS Stade was recalculated using the combination ADYPMO-FRETI. Good agreement between theoretical calculations and experimental results give an insight into the validity and efficiency of the underlying theoretical model and the applied retransformation method. (Auth.)

  15. Analytic structure and power series expansion of the Jost function for the two-dimensional problem

    International Nuclear Information System (INIS)

    Rakityansky, S A; Elander, N

    2012-01-01

    For a two-dimensional quantum-mechanical problem, we obtain a generalized power series expansion of the S-matrix that can be done near an arbitrary point on the Riemann surface of the energy, similar to the standard effective-range expansion. In order to do this, we consider the Jost function and analytically factorize its momentum dependence that causes the Jost function to be a multi-valued function. The remaining single-valued function of the energy is then expanded in the power series near an arbitrary point in the complex energy plane. A systematic and accurate procedure has been developed for calculating the expansion coefficients. This makes it possible to obtain a semi-analytic expression for the Jost function (and therefore for the S-matrix) near an arbitrary point on the Riemann surface and use it, for example, to locate the spectral points (bound and resonant states) as the S-matrix poles. The method is applied to a model similar to those used in the theory of quantum dots. (paper)

  16. Doppler-musical instrument

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T.J. [National Research Institute for Metals, Tsukuba, Ibaraki (Japan); Watanabe, N. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Shibata, K. [Institute for Materials Research, Tohoku Univ., Sendai, Miyagi (Japan)

    2001-03-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 {mu}eV, even when the ultra-high energy resolution of {delta}E{approx}0.03 {mu}eV is attained. (author)

  17. Thermocline thermal storage systems for concentrated solar power plants: One-dimensional numerical model and comparative analysis

    DEFF Research Database (Denmark)

    Modi, Anish; Pérez-Segarra, Carlos David

    2014-01-01

    Concentrated solar power plants have attracted increasing interest from researchers and governments all over the world in recent years. An important part of these plants is the storage system which improves dispatchability and makes the plant more reliable. In this paper, a one-dimensional transi...

  18. Evaluation of Reduced Power Spectra from Three-Dimensional k-Space

    Science.gov (United States)

    Saur, J.; von Papen, M.

    2014-12-01

    We present a new tool to evaluate one dimensional reduced power spectral densities (PSD) from arbitrary energy distributions in kk-space. This enables us to calculate the power spectra as they are measured in spacecraft frame for any given measurement geometry assuming Taylor's frozen-in approximation. It is possible to seperately calculate the diagonal elements of the spectral tensor and also to insert additional, non-turbulent energy in kk-space (e.g. mirror mode waves). Given a critically balanced turbulent cascade with k∥˜kα⊥k_\\|sim k_perp^alpha, we explore the implications on the spectral form of the PSD and the functional dependence of the spectral index κkappa on the field-to-flow angle θtheta between plasma flow and background magnetic field. We show that critically balanced turbulence develops a θtheta-independent cascade with the spectral slope of the perpendicular cascade κ(θ=90∘)kappa(theta{=}90^circ). This happens at frequencies f>fmaxf>f_mathrm{max}, where fmax(L,α,θ)f_mathrm{max}(L,alpha,theta) is a function of outer scale LL, critical balance exponent αalpha and field-to-flow angle θtheta. We also discuss potential damping terms acting on the kk-space distribution of energy and their effect on the PSD. Further, we show that the functional dependence κ(θ)kappa(theta) as found by textit{Horbury et al.} (2008) and textit{Chen et al.} (2010) can be explained with a damped critically balanced turbulence model.

  19. Forward Modeling of Reduced Power Spectra from Three-dimensional k-space

    Science.gov (United States)

    von Papen, Michael; Saur, Joachim

    2015-06-01

    We present results from a numerical forward model to evaluate one-dimensional reduced power spectral densities (PSDs) from arbitrary energy distributions in {\\boldsymbol{k}} -space. In this model, we can separately calculate the diagonal elements of the spectral tensor for incompressible axisymmetric turbulence with vanishing helicity. Given a critically balanced turbulent cascade with {{k}\\parallel }∼ k\\bot α and α \\lt 1, we explore the implications on the reduced PSD as a function of frequency. The spectra are obtained under the assumption of Taylor’s hypothesis. We further investigate the functional dependence of the spectral index κ on the field-to-flow angle θ between plasma flow and background magnetic field from MHD to electron kinetic scales. We show that critically balanced turbulence asymptotically develops toward θ-independent spectra with a slope corresponding to the perpendicular cascade. This occurs at a transition frequency {{f}2D}(L,α ,θ ), which is analytically estimated and depends on outer scale L, critical balance exponent α, and field-to-flow angle θ. We discuss anisotropic damping terms acting on the {\\boldsymbol{k}} -space distribution of energy and their effects on the PSD. Further, we show that the spectral anisotropies κ (θ ) as found by Horbury et al. and Chen et al. in the solar wind are in accordance with a damped critically balanced cascade of kinetic Alfvén waves. We also model power spectra obtained by Papen et al. in Saturn’s plasma sheet and find that the change of spectral indices inside 9 {{R}s} can be explained by damping on electron scales.

  20. Application of a Novel Laser-Doppler Velocimeter for Turbulence: Structural Measurements in Turbulent Boundary Layers

    National Research Council Canada - National Science Library

    Lowe, Kevin T; Simpson, Roger L

    2006-01-01

    An advanced laser-Doppler velocimeter (LDV), deemed the 'comprehensive LDV', is designed to acquire fully-resolved turbulence structural measurements in high Reynolds number two- and three-dimensional turbulent boundary layers...

  1. Principles of doppler tomography

    International Nuclear Information System (INIS)

    Juhlin, P.

    1992-08-01

    This paper shows how the radon transform can be used to determine vector fields. A scheme to determine the velocity field of a moving fluid by measurements with a continuous doppler signal is suggested. When the flow is confined to a bounded domain, as is the case in most applications, it can be uniquely decomposed into one gradiental and one rotational part. The former vanishes if the fluid is incompressible and source-free, and the latter can be completely reconstructed by the methods proposed in this paper if the domain is simply connected. Special attention is paid to laminar flow in a long cylindrical vessel with circular cross-section. Under such conditions the flow profile becomes parabolic, which makes the vessel recognizable as a typical 'N-shaped' pattern in an image describing the rotation of the velocity field. The vessel yields the same doppler tomographic pattern, no matter how it is sectioned. The ideas presented should be applicable also when studying the flow in blood vessels, even if the flow profile in these is not quite parabolic. The discrepancies only make the 'N-shape' somewhat distorted

  2. Power-induced evolution and increased dimensionality of nonlinear modes in reorientational soft matter.

    Science.gov (United States)

    Laudyn, Urszula A; Jung, Paweł S; Zegadło, Krzysztof B; Karpierz, Miroslaw A; Assanto, Gaetano

    2014-11-15

    We demonstrate the evolution of higher order one-dimensional guided modes into two-dimensional solitary waves in a reorientational medium. The observations, carried out at two different wavelengths in chiral nematic liquid crystals, are in good agreement with a simple nonlocal nonlinear model.

  3. Dimensional characteristics of welds performed on AISI 1045 steel by means of the application of high power diode laser

    International Nuclear Information System (INIS)

    Sanchez-Castillo, A.; Pou, J.; Lusquinos, F.; Quintero, F.; Soto, R.; Boutinguiza, M.; Saavedra, M.; Perez-Amor, M.

    2004-01-01

    The named High Power diode Laser (HPDL), emits a beam of optical energy generated by diode stimulation and offers the capability of supplying levels of power up to 6 kW. The objective of this research work was to study the main welding variables and their effects on dimensional characteristics of the beads performed by means of application of this novel laser. The results obtained, show that HPDL, is an energy source able to perform welds on AISI 1045 steel plates under conduction mode, without any kind of mechanized preparation, preheating or post-weld treatment and, without filler metal application. (Author) 16 refs

  4. Ambiguity resolution for satellite Doppler positioning systems

    Science.gov (United States)

    Argentiero, P.; Marini, J.

    1979-01-01

    The implementation of satellite-based Doppler positioning systems frequently requires the recovery of transmitter position from a single pass of Doppler data. The least-squares approach to the problem yields conjugate solutions on either side of the satellite subtrack. It is important to develop a procedure for choosing the proper solution which is correct in a high percentage of cases. A test for ambiguity resolution which is the most powerful in the sense that it maximizes the probability of a correct decision is derived. When systematic error sources are properly included in the least-squares reduction process to yield an optimal solution the test reduces to choosing the solution which provides the smaller valuation of the least-squares loss function. When systematic error sources are ignored in the least-squares reduction, the most powerful test is a quadratic form comparison with the weighting matrix of the quadratic form obtained by computing the pseudoinverse of a reduced-rank square matrix. A formula for computing the power of the most powerful test is provided. Numerical examples are included in which the power of the test is computed for situations that are relevant to the design of a satellite-aided search and rescue system.

  5. Deconvoluting double Doppler spectra

    International Nuclear Information System (INIS)

    Ho, K.F.; Beling, C.D.; Fung, S.; Chan, K.L.; Tang, H.W.

    2001-01-01

    The successful deconvolution of data from double Doppler broadening of annihilation radiation (D-DBAR) spectroscopy is a promising area of endeavour aimed at producing momentum distributions of a quality comparable to those of the angular correlation technique. The deconvolution procedure we test in the present study is the constrained generalized least square method. Trials with computer simulated DDBAR spectra are generated and deconvoluted in order to find the best form of regularizer and the regularization parameter. For these trials the Neumann (reflective) boundary condition is used to give a single matrix operation in Fourier space. Experimental D-DBAR spectra are also subject to the same type of deconvolution after having carried out a background subtraction and using a symmetrize resolution function obtained from an 85 Sr source with wide coincidence windows. (orig.)

  6. Doppler ultrasound imaging techniques for assessment of synovial inflammation

    Directory of Open Access Journals (Sweden)

    Filippucci E

    2013-09-01

    Full Text Available Emilio Filippucci,1 Fausto Salaffi,1 Marina Carotti,2 Walter Grassi1 1Rheumatology Department, Polytechnic University of the Marche, Ancona, Italy; 2Department of Radiology, Polytechnic University of the Marche, Ancona, Italy Abstract: Ultrasound is an evolving technique, and the rapid progress made in ultrasound technology over the past ten years has dramatically increased its range of applications in rheumatology. One of the most exciting advances is the use of Doppler ultrasound imaging in the assessment of blood flow abnormalities at the synovial tissue level in patients with chronic inflammatory arthritis. This review describes the Doppler techniques available and their main applications in patients with inflammatory arthritis, discusses the evidence supporting their use, and outlines the latest advances in hardware and software. Spectral, color, and power Doppler allow sensitive assessment of vascular abnormalities at the synovial tissue level. Use of contrast agents enhances visualization of the small synovial vessels using color or power Doppler ultrasound and allows for accurate characterization of the rheumatoid pannus. Doppler techniques represent a unique method for assessment of synovial inflammation, showing blood flow characteristics in real time. They are safe, noninvasive, cost-effective, and have high sensitivity in revealing and monitoring synovitis. However, several questions still need to be answered. In the near future, the Doppler techniques described here, together with upcoming hardware and software facilities, will be investigated further and a consensus will be reached on their feasibility and appropriate use in daily rheumatologic practice. Keywords: power and color Doppler techniques, ultrasound, contrast media, synovitis, rheumatoid arthritis

  7. 3D atom microscopy in the presence of Doppler shift

    Science.gov (United States)

    Rahmatullah; Chuang, You-Lin; Lee, Ray-Kuang; Qamar, Sajid

    2018-03-01

    The interaction of hot atoms with laser fields produces a Doppler shift, which can severely affect the precise spatial measurement of an atom. We suggest an experimentally realizable scheme to address this issue in the three-dimensional position measurement of a single atom in vapors of rubidium atoms. A three-level Λ-type atom-field configuration is considered where a moving atom interacts with three orthogonal standing-wave laser fields and spatial information of the atom in 3D space is obtained via an upper-level population using a weak probe laser field. The atom moves with velocity v along the probe laser field, and due to the Doppler broadening the precision of the spatial information deteriorates significantly. It is found that via a microwave field, precision in the position measurement of a single hot rubidium atom can be attained, overcoming the limitation posed by the Doppler shift.

  8. COMMIX-PPC: A three-dimensional transient multicomponent computer program for analyzing performance of power plant condensers

    International Nuclear Information System (INIS)

    Chien, T.H.; Domanus, H.M.; Sha, W.T.

    1993-02-01

    The COMMIX-PPC computer pregrain is an extended and improved version of earlier COMMIX codes and is specifically designed for evaluating the thermal performance of power plant condensers. The COMMIX codes are general-purpose computer programs for the analysis of fluid flow and heat transfer in complex Industrial systems. In COMMIX-PPC, two major features have been added to previously published COMMIX codes. One feature is the incorporation of one-dimensional equations of conservation of mass, momentum, and energy on the tube stile and the proper accounting for the thermal interaction between shell and tube side through the porous-medium approach. The other added feature is the extension of the three-dimensional conservation equations for shell-side flow to treat the flow of a multicomponent medium. COMMIX-PPC is designed to perform steady-state and transient. Three-dimensional analysis of fluid flow with heat transfer tn a power plant condenser. However, the code is designed in a generalized fashion so that, with some modification, it can be used to analyze processes in any heat exchanger or other single-phase engineering applications. Volume I (Equations and Numerics) of this report describes in detail the basic equations, formulation, solution procedures, and models for a phenomena. Volume II (User's Guide and Manual) contains the input instruction, flow charts, sample problems, and descriptions of available options and boundary conditions

  9. Ultrasound-detected bone erosion is a relapse risk factor after discontinuation of biologic disease-modifying antirheumatic drugs in patients with rheumatoid arthritis whose ultrasound power Doppler synovitis activity and clinical disease activity are well controlled.

    Science.gov (United States)

    Kawashiri, Shin-Ya; Fujikawa, Keita; Nishino, Ayako; Okada, Akitomo; Aramaki, Toshiyuki; Shimizu, Toshimasa; Umeda, Masataka; Fukui, Shoichi; Suzuki, Takahisa; Koga, Tomohiro; Iwamoto, Naoki; Ichinose, Kunihiro; Tamai, Mami; Mizokami, Akinari; Nakamura, Hideki; Origuchi, Tomoki; Ueki, Yukitaka; Aoyagi, Kiyoshi; Maeda, Takahiro; Kawakami, Atsushi

    2017-05-25

    In the present study, we explored the risk factors for relapse after discontinuation of biologic disease-modifying antirheumatic drug (bDMARD) therapy in patients with rheumatoid arthritis (RA) whose ultrasound power Doppler (PD) synovitis activity and clinical disease activity were well controlled. In this observational study in clinical practice, the inclusion criteria were based on ultrasound disease activity and clinical disease activity, set as low or remission (Disease Activity Score in 28 joints based on erythrocyte sedimentation rate Ultrasound was performed in 22 joints of bilateral hands at discontinuation for evaluating synovitis severity and presence of bone erosion. Patients with a maximum PD score ≤1 in each joint were enrolled. Forty patients with RA were consecutively recruited (November 2010-March 2015) and discontinued bDMARD therapy. Variables at the initiation and discontinuation of bDMARD therapy that were predictive of relapse during the 12 months after discontinuation were assessed. The median patient age was 54.5 years, and the median disease duration was 3.5 years. Nineteen (47.5%) patients relapsed during the 12 months after the discontinuation of bDMARD therapy. Logistic regression analysis revealed that only the presence of bone erosion detected by ultrasound at discontinuation was predictive of relapse (OR 8.35, 95% CI 1.78-53.2, p = 0.006). No clinical characteristics or serologic biomarkers were significantly different between the relapse and nonrelapse patients. The ultrasound synovitis scores did not differ significantly between the groups. Our findings are the first evidence that ultrasound bone erosion may be a relapse risk factor after the discontinuation of bDMARD therapy in patients with RA whose PD synovitis activity and clinical disease activity are well controlled.

  10. Transversal Doppler-Fizeau effect

    International Nuclear Information System (INIS)

    Subacius, E.

    1981-01-01

    The relativistic calculation of the Doppler-Fizeau effect foresees a second grade redshift due to the proper time dilation of a moving object. The relevance of this relativistic effect on astrophysical observation is discussed, herein. (Auhor) [pt

  11. Glare Spot Phase Doppler Anemometry

    OpenAIRE

    Hespel, Camille; Ren, Kuan Fang; Gréhan, Gérard; Onofri, Fabrice

    2006-01-01

    International audience; The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index is also necessary since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemo...

  12. On-line generation of three-dimensional core power distribution using incore detector signals to monitor safety limits

    International Nuclear Information System (INIS)

    Jang, Jin Wook; Lee, Ki Bog; Na, Man Gyun; Lee, Yoon Joon

    2004-01-01

    It is essential in commercial reactors that the safety limits imposed on the fuel pellets and fuel clad barriers, such as the Linear Power Density (LPD) and the Departure from Nucleate Boiling Ratio (DNBR), are not violated during reactor operations. In order to accurately monitor the safety limits of current reactor states, a detailed three-dimensional (3D) core power distribution should be estimated from the in-core detector signals. In this paper, we propose a calculation methodology for detailed 3D core power distribution, using in-core detector signals and core monitoring constants such as the 3D Coupling Coefficients (3DCC), node power fraction, and pin-to-node factors. Also, the calculation method for several core safety parameters is introduced. The core monitoring constants for the real core state are promptly provided by the core design code and on-line MASTER(Multi-purpose Analyzer for Static and Transient Effects of Reactors), coupled with the core monitoring program. Through the plant computer, core state variables, which include reactor thermal power, control rod bank position, boron concentration, inlet moderator temperature, and flow rate, are supplied as input data for MASTER. MASTER performs the core calculation based on the neutron balance equation and generates several core monitoring constants corresponding to the real core state in addition to the expected core power distribution. The accuracy of the developed method is verified through a comparison with the current CECOR method. Because in all the verification calculation cases the proposed method shows a more conservative value than the best estimated value and a less conservative one than the current CECOR and COLSS methods, it is also confirmed that this method secures a greater operating margin through the simulation of the YGN-3 cycle-1 core from the viewpoint of the power peaking factor for the LPD and the pseudo hot pin axial power distribution for the DNBR calculation

  13. Digital simulation of two-dimensional random fields with arbitrary power spectra and non-Gaussian probability distribution functions.

    Science.gov (United States)

    Yura, Harold T; Hanson, Steen G

    2012-04-01

    Methods for simulation of two-dimensional signals with arbitrary power spectral densities and signal amplitude probability density functions are disclosed. The method relies on initially transforming a white noise sample set of random Gaussian distributed numbers into a corresponding set with the desired spectral distribution, after which this colored Gaussian probability distribution is transformed via an inverse transform into the desired probability distribution. In most cases the method provides satisfactory results and can thus be considered an engineering approach. Several illustrative examples with relevance for optics are given.

  14. Thermostatistical properties of q-deformed bosons trapped in a D-dimensional power-law potential

    International Nuclear Information System (INIS)

    Su Guozhen; Chen Jincan; Chen Lixuan

    2003-01-01

    The thermostatistical properties of an ideal gas of q-deformed bosons trapped in a D-dimensional power-law potential are studied, based on the q-deformed Bose-Einstein distribution. The effects of q-deformation on the properties of the system are discussed. It is shown that q-deformed bosons (q ≠ 1) possess many different characteristics from those of ordinary bosons, which include the condition that Bose-Einstein condensation (BEC) occurs, the critical temperature and the continuity of heat capacity

  15. Integrated three-dimensional module heat exchanger for power electronics cooling

    Science.gov (United States)

    Bennion, Kevin; Lustbader, Jason

    2013-09-24

    Embodiments discussed herein are directed to a power semiconductor packaging that removes heat from a semiconductor package through one or more cooling zones that are located in a laterally oriented position with respect to the semiconductor package. Additional embodiments are directed to circuit elements that are constructed from one or more modular power semiconductor packages.

  16. An Observational Study of a Prefrontal Convective Rainband Using Tamex Single-and Dual-Doppler Data

    Science.gov (United States)

    1991-01-01

    integration from the surface. Other Doppler studies, e.g., Chong and Testud (1983), Lin et al. 37 (1986), etc, also showed similiar results. 4.3 Variational...Atmos. Sci., 39, 258- 279. Chong, M., and J. Testud , 1983: Three-Dimensional Wind Field Analysis from Dual-Doppler Radar Data. Part III: The Boundary

  17. Korea-China Joint R and D on Doppler Lidar Technology

    International Nuclear Information System (INIS)

    Cha, Hyung Ki; Kim, D. H.; Kwon, S. O.; Yang, K. H.; Song, I. K.

    2009-03-01

    Doppler lidar technology is to monitor atmospheric wind velocity by measuring the light scattering signals between a laser and aerosol particles or molecules existing in the atmosphere. When the particles (or molecules) in the atmosphere are moving by wind force, the frequency of backscattering light is shifted by doppler effect, so that the wind velocity profile can be obtained by measurement of the shifted frequencies. When the laser radiation is scanned in four different direction, three dimensional wind profiles are obtained. The Anhui Institute of Optics and Fine Mechanics under the China Academy of Sciences has developed and operated the doppler lidar system for long time. In this project we want to developed a new technologies adopted to the chinese doppler system and to test the updated In the process of collaboration between China and Korea research teams, we want to learn the state-of-art technology involved in the doppler lidar system

  18. Two-dimensional electron flow in pulsed power transmission lines and plasma opening switches

    International Nuclear Information System (INIS)

    Church, B.W.; Longcope, D.W.; Ng, C.K.; Sudan, R.N.

    1991-01-01

    The operation of magnetically insulated transmission lines (MITL) and the interruption of current in a plasma opening switch (POS) are determined by the physics of the electrons emitted by the cathode surface. A mathematical model describes the self-consistent two-dimensional flow of an electron fluid. A finite element code, FERUS, has been developed to solve the two equations which describe Poisson's and Ampere's law in two dimensions. The solutions from this code are obtained for parameters where the electron orbits are considerably modified by the self-magnetic field of the current. Next, the self-insulated electron flow in a MITL with a step change in cross-section is studied using a conventional two-dimensional fully electromagnetic particle-in-cell code, MASK. The equations governing two-dimensional quasi-static electron flow are solved numerically by a third technique which is suitable for predicting current interruption in a POS. The object of the study is to determine the critical load impedance, Z CL , required for current interruption for a given applied voltage, cathode voltage and plasma length. (author). 9 refs, 5 figs

  19. On-chip micro-power: three-dimensional structures for micro-batteries and micro-supercapacitors

    Science.gov (United States)

    Beidaghi, Majid; Wang, Chunlei

    2010-04-01

    With the miniaturization of portable electronic devices, there is a demand for micro-power source which can be integrated on the semiconductor chips. Various micro-batteries have been developed in recent years to generate or store the energy that is needed by microsystems. Micro-supercapacitors are also developed recently to couple with microbatteries and energy harvesting microsystems and provide the peak power. Increasing the capacity per footprint area of micro-batteries and micro-supercapacitors is a great challenge. One promising route is the manufacturing of three dimensional (3D) structures for these micro-devices. In this paper, the recent advances in fabrication of 3D structure for micro-batteries and micro-supercapacitors are briefly reviewed.

  20. Magnetic-field-free thermoelectronic power conversion based on graphene and related two-dimensional materials

    Science.gov (United States)

    Wanke, R.; Hassink, G. W. J.; Stephanos, C.; Rastegar, I.; Braun, W.; Mannhart, J.

    2016-06-01

    Mobile energy converters require, in addition to high conversion efficiency and low cost, a low mass. We propose to utilize thermoelectronic converters that use 2D-materials such as graphene for their gate electrodes. Deriving the ultimate limit for their specific energy output, we show that the positive energy output is likely close to the fundamental limit for any conversion of heat into electric power. These converters may be valuable as electric power sources of spacecraft, and with the addition of vacuum enclosures, for power generation in electric planes and cars.

  1. Enhanced thermoelectric power in two-dimensional transition metal dichalcogenide monolayers

    KAUST Repository

    Pu, Jiang; Kanahashi, Kaito; Cuong, Nguyen Thanh; Chen, Chang-Hsiao; Li, Lain-Jong; Okada, Susumu; Ohta, Hiromichi; Takenobu, Taishi

    2016-01-01

    The carrier-density-dependent conductance and thermoelectric properties of large-area MoS2 and WSe2 monolayers are simultaneously investigated using the electrolyte gating method. The sign of the thermoelectric power changes across the transistor

  2. High-resolution velocimetry in energetic tidal currents using a convergent-beam acoustic Doppler profiler

    Science.gov (United States)

    Sellar, Brian; Harding, Samuel; Richmond, Marshall

    2015-08-01

    An array of single-beam acoustic Doppler profilers has been developed for the high resolution measurement of three-dimensional tidal flow velocities and subsequently tested in an energetic tidal site. This configuration has been developed to increase spatial resolution of velocity measurements in comparison to conventional acoustic Doppler profilers (ADPs) which characteristically use divergent acoustic beams emanating from a single instrument. This is achieved using geometrically convergent acoustic beams creating a sample volume at the focal point of 0.03 m3. Away from the focal point, the array is also able to simultaneously reconstruct three-dimensional velocity components in a profile throughout the water column, and is referred to herein as a convergent-beam acoustic Doppler profiler (C-ADP). Mid-depth profiling is achieved through integration of the sensor platform with the operational commercial-scale Alstom 1 MW DeepGen-IV Tidal Turbine deployed at the European Marine Energy Center, Orkney Isles, UK. This proof-of-concept paper outlines the C-ADP system configuration and comparison to measurements provided by co-installed reference instrumentation. Comparison of C-ADP to standard divergent ADP (D-ADP) velocity measurements reveals a mean difference of 8 mm s-1, standard deviation of 18 mm s-1, and an order of magnitude reduction in realisable length scale. C-ADP focal point measurements compared to a proximal single-beam reference show peak cross-correlation coefficient of 0.96 over 4.0 s averaging period and a 47% reduction in Doppler noise. The dual functionality of the C-ADP as a profiling instrument with a high resolution focal point make this configuration a unique and valuable advancement in underwater velocimetry enabling improved quantification of flow turbulence. Since waves are simultaneously measured via profiled velocities, pressure measurements and surface detection, it is expected that derivatives of this system will be a powerful tool in

  3. DOPPLER SIGNATURES OF THE ATMOSPHERIC CIRCULATION ON HOT JUPITERS

    International Nuclear Information System (INIS)

    Showman, Adam P.; Lewis, Nikole K.; Fortney, Jonathan J.; Shabram, Megan

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation—and Doppler signature—of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blueshifted and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps these waves and inhibits jet formation. As a result, this second regime exhibits a circulation dominated by high-altitude, day-to-night airflow, leading to a predominantly blueshifted Doppler signature during transit. We present state-of-the-art circulation models including non-gray radiative transfer to quantify this regime shift and the resulting Doppler signatures; these models suggest that cool planets like GJ 436b lie in the first regime, HD 189733b is transitional, while planets hotter than HD 209458b lie in the second regime. Moreover, we show how the amplitude of the Doppler shifts constrains the strength of frictional drag in the upper atmospheres of hot Jupiters. If due to winds, the ∼2 km s –1 blueshift inferred on HD 209458b may require drag time constants as short as 10 4 -10 6 s, possibly the result of Lorentz-force braking on this planet's hot dayside.

  4. Investigation of Kelvin-Helmholtz Instability in the boundary layer using Doppler lidar and radiosonde data

    Science.gov (United States)

    Das, Subrata Kumar; Das, Siddarth Shankar; Saha, Korak; Murali Krishna, U. V.; Dani, K. K.

    2018-04-01

    Characteristics of Kelvin Helmholtz Instability (KHI) using Doppler wind lidar observation have rarely been reported during the Indian summer monsoon season. In this paper, we present a case study of KHI near planetary boundary layer using Doppler wind lidar and radiosonde measurements at Mahabubnagar, a tropical Indian station. The data was collected during the Integrated Ground Observation Campaign (June-October 2011) under the Cloud Aerosol Interaction and Precipitation Enhancement EXperiment-2011. The continuous wind lidar observation during 10-16 August 2011 shows there is an increase in carrier-to-noise ratio values near planetary boundary layer from 03:00 to 11:00 LT on 13 August; reveals the formation of KHI. There is a strong power bursts pattern corresponding to high turbulence characteristics in the early half of the day. The KHI temporal evolution from initial to dissipating stage is observed with clear variation in the carrier-to-noise ratio values. The observed KHI billows are in the height between 600 and 1200 m and lasted for about 7.5 h. The vertical velocity from Doppler lidar measurement shows the presence of updrafts after breaking of KHI in the boundary layer. The presence of strong wind shear, high stability parameter, low Richardson number and high relative humidity during the enhanced carrier-to-noise ratio period indicates the ideal condition for the formation and persistence of this dynamic instability. A typical characteristic of trapped humidity above the KHI billows suggest the presence of strong inversion. A wavelet analysis of 3-dimensional wind components show dominant periodicity of 45-65 min and the periodicity in vertical wind is more prominent.

  5. Using the global positioning satellite system to determine attitude rates using doppler effects

    Science.gov (United States)

    Campbell, Charles E. (Inventor)

    2003-01-01

    In the absence of a gyroscope, the attitude and attitude rate of a receiver can be determined using signals received by antennae on the receiver. Based on the signals received by the antennae, the Doppler difference between the signals is calculated. The Doppler difference may then be used to determine the attitude rate. With signals received from two signal sources by three antennae pairs, the three-dimensional attitude rate is determined.

  6. THREE-DIMENSIONAL GEOFILTRATIONAL MODEL OF THE ROGUN HYDRO POWER PLANT CONSTRUCTION SITE

    Directory of Open Access Journals (Sweden)

    Khokhotva Sergey Nikolaevich

    2017-05-01

    Full Text Available The article deals with technique of creation and results of calculations of the three-dimensional geofiltrational model of the Rogun HPP construction site. When performing works on creation of the Rogun HPP three-dimensional geofiltration model, geological and hydrogeological conditions of the Rogun HPP construction site were analyzed. They showed that the construction site consists mostly of fractured rocks of various weathering degrees. In terms of preservation, four preservation zones were identified in the rock mass. These zones define the features of hydrogeological conditions that have emerged in the area of construction. Calculation results illustrated the absence of seepage areas on the lower slope of dam; this is the indication of normal operation of the dam impervious circuit. The drainage system of the underground hydropower plant has a high efficiency. Operation of the drainage galleries complex leads to a significant reduction of piezometric pressure on roofs of the machine and transformer halls. Above the underground structures a completely drained area is formed. Completed forecast calculations on geofiltration model of the Rogun hydropower plant determine the hydrostatic pressure and piezometric pressure at any point of the modeled area. These data can be used as loads while designing of lining of underground workings.

  7. Moving Target Detection With Compact Laser Doppler Radar

    Science.gov (United States)

    Sepp, G.; Breining, A.; Eisfeld, W.; Knopp, R.; Lill, E.; Wagner, D.

    1989-12-01

    This paper describes an experimental integrated optronic system for detection and tracking of moving objects. The system is based on a CO2 waveguide laser Doppler ra-dar with homodyne receiver and galvanometer mirror beam scanner. A "hot spot" seeker consisting of a thermal imager with image processor transmits the coordinates of IR-emitting, i.e. potentially powered, objects to the laser radar scanner. The scanner addresses these "hot" locations operating in a large field-of-view (FOV) random ac-cess mode. Hot spots exhibiting a Doppler shifted laser signal are indicated in the thermal image by velocity-to-colour encoded markers. After switching to a small FOV scanning mode, the laser Doppler radar is used to track fast moving objects. Labora-tory and field experiments with moving objects including rotating discs, automobiles and missiles are described.

  8. Modeling and processing of laser Doppler reactive hyperaemia signals

    Science.gov (United States)

    Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre

    2003-07-01

    Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.

  9. Value of tissue Doppler-derived Tei index and two-dimensional speckle tracking imaging derived longitudinal strain on predicting outcome of patients with light-chain cardiac amyloidosis.

    Science.gov (United States)

    Liu, Dan; Hu, Kai; Herrmann, Sebastian; Cikes, Maja; Ertl, Georg; Weidemann, Frank; Störk, Stefan; Nordbeck, Peter

    2017-06-01

    Prognosis of patients with light-chain cardiac amyloidosis (AL-CA) is poor. Speckle tracking imaging (STI) derived longitudinal deformation parameters and Doppler-derived left ventricular (LV) Tei index are valuable predictors of outcome in patients with AL-CA. We estimated the prognostic utility of Tei index and deformation parameters in 58 comprehensively phenotyped patients with AL-CA after a median follow-up of 365 days (quartiles 121, 365 days). The primary end point was all-cause mortality. 19 (33%) patients died during follow-up. Tei index (0.89 ± 0.29 vs. 0.61 ± 0.16, p < 0.001) and E to global early diastolic strain rate ratio (E/GLSR dias ) were higher while global longitudinal systolic strain (GLS sys ) was lower in non-survivors than in survivors (all p < 0.05). Tei index, NYHA functional class, GLS sys and E/GLSR dias were independent predictors of all-cause mortality risk, and Tei index ≥0.9 (HR 7.01, 95% CI 2.43-20.21, p < 0.001) was the best predictor of poor outcome. Combining Tei index and GLS sys yielded the best results on predicting death within 1 year (100% with Tei index ≥0.9 and GLS sys ≤13%) or survival (95% with Tei index ≤0.9 and GLS sys ≥13%). We conclude that 1-year mortality risk in AL-CA patients can be reliably predicted using Tei index or deformation parameters, with combined analysis offering best performance.

  10. Maximisation of the Doppler effect in thermal reactors

    International Nuclear Information System (INIS)

    Bende, E.E.

    1998-03-01

    Increase of the fuel temperature in a nuclear reactor leads, or can lead, to (1) A Doppler broadening of the resonances of the nuclides in the fuel; (2) An expansion of the fuel; and (3) A shift of the Maxwellian part of the spectrum to higher energies. These processes together introduce a certain amount of reactivity, which can be expressed in the so-called fuel temperature reactivity coefficient. The reactivity effect of the third process is very small, because the Maxwell spectrum is to a major extent determined by the moderator temperature. Moreover, the reactivity effect due to an expansion of the fuel is small too, for most thermal systems. When the second and third processes can be neglected, the fuel temperature reactivity effect is fully determined by the Doppler effect. The fuel temperature reactivity coefficient is then called the Doppler coefficient of reactivity. The Doppler broadening of the resonances causes an increase of resonance absorption, due to a decrease of self-shielding. The competition between resonance fission at the one hand and resonance capture at the other hand determines the sign and magnitude of the reactivity induced by an increase of the fuel temperature. In well-designed nuclear reactors the Doppler effect due to resonance capture by fertile nuclides exceeds the Doppler effect due to resonance fission, which implies that an increase of the fuel temperature causes a negative reactivity effect and a correspondingly negative Doppler coefficient. Since the Doppler effect is a prompt effect, occurring simultaneously with the dissipation of kinetic energy of the fission products into temperature, it is very important in the study of rapid power transients. In this report, the Doppler coefficient of reactivity is defined in chapter 2. Chapter 3 discusses the geometry of the unit-cell for which the calculations are performed and describes the fuel types that have been investigated. In chapter 4 the 'Doppler efficiency' is introduced and

  11. Multi-dimensional diagnostics of high power ion beams by Arrayed Pinhole Camera System

    International Nuclear Information System (INIS)

    Yasuike, K.; Miyamoto, S.; Shirai, N.; Akiba, T.; Nakai, S.; Imasaki, K.; Yamanaka, C.

    1993-01-01

    The authors developed multi-dimensional beam diagnostics system (with spatially and time resolution). They used newly developed Arrayed Pinhole Camera (APC) for this diagnosis. The APC can get spatial distribution of divergence and flux density. They use two types of particle detectors in this study. The one is CR-39 can get time integrated images. The other one is gated Micro-Channel-Plate (MCP) with CCD camera. It enables time resolving diagnostics. The diagnostics systems have resolution better than 10mrad divergence, 0.5mm spatial resolution on the objects respectively. The time resolving system has 10ns time resolution. The experiments are performed on Reiden-IV and Reiden-SHVS induction linac. The authors get time integrated divergence distributions on Reiden-IV proton beam. They also get time resolved image on Reiden-SHVS

  12. Multi-dimensional Analysis Method of Hydrogen Combustion in the Containment of a Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jongtae; Hong, Seongwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Gun Hong [Kyungwon E and C Co., Seongnam (Korea, Republic of)

    2014-05-15

    The most severe case is the occurrence of detonation, which induces a few-fold greater pressure load on the containment wall than a deflagration flame. The occurrence of a containment-wise global detonation is prohibited by a national regulation. The compartments located in the flow path such as steam generator compartment, annular compartment, and dome region are likely to have highly-concentrated hydrogen. If it is found that hydrogen concentration in any compartment is far below a detonation criterion during an accident progression, it can be thought that the occurrence of a detonative explosion in a compartment is excluded. However, if it is not, it is necessary to evaluate the characteristics of flame acceleration in the containment. The possibility of a flame transition from a deflagration to a detonation (DDT) can be evaluated from a calculated hydrogen distribution in a compartment by using sigma-lambda criteria. However, this method can provide a very conservative result because the geometric characteristics of a real compartment are not considered well. In order to evaluate the containment integrity from a threat of a hydrogen explosion, it is necessary to establish an integrated evaluation system, which includes a lumped-parameter and detail analysis methods. In this study, a method for the multi-dimensional analysis of hydrogen combustion is proposed to mechanistically evaluate the flame acceleration characteristics with a geometric effect. The geometry of the containment is modeled 3-dimensionally using a CAD tool. To resolve a propagating flame front, an adaptive mesh refinement method is coupled with a combustion analysis solver.

  13. A two-dimensional simulator of the neutronic behaviour of low power fast reactors

    International Nuclear Information System (INIS)

    Penha, M.A.V.R. da.

    1984-01-01

    A model to simulate the temporal neutronic behaviour of fast breeder reactors was developed. The effective cross-sections are corrected, whenever the reactor state change; by using linear correlations and interpolation schemes with data contained in a library previously compiled. This methodology was coupled with a simplified spatial neutronic calculation to investigate the temporal behaviour of neutronic parameters such as breeding gain, flux and power. (Author) [pt

  14. Bose-Einstein condensation in chains with power-law hoppings: Exact mapping on the critical behavior in d -dimensional regular lattices

    Science.gov (United States)

    Dias, W. S.; Bertrand, D.; Lyra, M. L.

    2017-06-01

    Recent experimental progress on the realization of quantum systems with highly controllable long-range interactions has impelled the study of quantum phase transitions in low-dimensional systems with power-law couplings. Long-range couplings mimic higher-dimensional effects in several physical contexts. Here, we provide the exact relation between the spectral dimension d at the band bottom and the exponent α that tunes the range of power-law hoppings of a one-dimensional ideal lattice Bose gas. We also develop a finite-size scaling analysis to obtain some relevant critical exponents and the critical temperature of the BEC transition. In particular, an irrelevant dangerous scaling field has to be taken into account when the hopping range is sufficiently large to make the effective dimensionality d >4 .

  15. Bose-Einstein condensation in chains with power-law hoppings: Exact mapping on the critical behavior in d-dimensional regular lattices.

    Science.gov (United States)

    Dias, W S; Bertrand, D; Lyra, M L

    2017-06-01

    Recent experimental progress on the realization of quantum systems with highly controllable long-range interactions has impelled the study of quantum phase transitions in low-dimensional systems with power-law couplings. Long-range couplings mimic higher-dimensional effects in several physical contexts. Here, we provide the exact relation between the spectral dimension d at the band bottom and the exponent α that tunes the range of power-law hoppings of a one-dimensional ideal lattice Bose gas. We also develop a finite-size scaling analysis to obtain some relevant critical exponents and the critical temperature of the BEC transition. In particular, an irrelevant dangerous scaling field has to be taken into account when the hopping range is sufficiently large to make the effective dimensionality d>4.

  16. The use of contrast-enhanced color doppler ultrasound in the differentiation of retinal detachment from vitreous membrane

    International Nuclear Information System (INIS)

    Han, Sang Suk; Chang, Seung Kook; Yoon, Jung Hee; Lee, Young Joon

    2001-01-01

    To compare the clinical utility of contrast-enhanced color Doppler US in the differentiation of retinal detachment (RD) from vitreous membrane (VM) with that of various conventional US modalities, and to analyze the enhancement patterns in cases showing an enhancement effect. In 32 eyes examined over a recent two-year period, RD (n=14) and VM (n=18) were confirmed by surgery (n=28) or clinical follow-up (n=4). In all cases, gray-scale, color Doppler, and power Doppler US were performed prior to contrast injection, and after the intravenous injection of Levovist (Schering, Berlin) by hand for 30 seconds at a dose of 2.5 g and a concentration of 300 mg/mL via an antecubital vein, contrast-enhanced color Doppler US was performed. At Doppler US, the diagnostic criterion for RD and VM was whether or not color signals were visualized in membranous structures. Diagnostic accuracy was 78% at gray-scale US, 81% at color Doppler US, 59% at power Doppler US, and 97% at contrast-enhanced color Doppler US. The sensitivity of color Doppler US to color signals in RD increased from 57% to 93% after contrast enhancement. The enhancement patterns observed were signal accentuation (n=3), signal extension (n=2), signal addition (n=3), and new signal visualization (n=5). Contrast-enhanced color Doppler US was the most accurate US modality for differentiating RD from VM, showing a significantly increased signal detection rate in RD

  17. Doppler broadening of cross sections

    International Nuclear Information System (INIS)

    Buckler, P.A.C.; Pull, I.C.

    1962-12-01

    Expressions for temperature dependent cross-sections in terms of resonance parameters are obtained, involving generalisations of the conventional Doppler functions, ψ and φ. Descriptions of Fortran sub-routines, which calculate broadened cross-sections in accordance with the derived formulae, are included. (author)

  18. Six-Dimensional Modeling of Coherent Bunch Instabilities and Related Feedback Systems using Power-Series Maps for the Lattice

    Energy Technology Data Exchange (ETDEWEB)

    Briggs, D.

    2003-07-07

    The authors have developed 6-dimensional phase-space code that tracks macroparticles for the study of coherent bunch instabilities and related feedback systems. The model is based on power-series maps to represent the lattice, and allows for straightforward inclusion of effects such as amplitude dependent tune shift, chromaticity, synchrotron oscillations, and synchrotron radiation. It simulates long range wake fields such as resistive-wall effects as well as the higher order modes in cavities. The model has served to study the dynamics relevant to the transverse feedback system currently being commissioned for the Advanced Light Source (ALS). Current work integrates earlier versions into a modular system that includes models for transverse and longitudinal feedback systems. It is designed to provide a modular approach to the dynamics and diagnostics, allowing a user to modify the model of a storage ring at run-time without recompilation.

  19. Three-dimensional strutted graphene grown by substrate-free sugar blowing for high-power-density supercapacitors

    Science.gov (United States)

    Wang, Xuebin; Zhang, Yuanjian; Zhi, Chunyi; Wang, Xi; Tang, Daiming; Xu, Yibin; Weng, Qunhong; Jiang, Xiangfen; Mitome, Masanori; Golberg, Dmitri; Bando, Yoshio

    2013-12-01

    Three-dimensional graphene architectures in the macroworld can in principle maintain all the extraordinary nanoscale properties of individual graphene flakes. However, current 3D graphene products suffer from poor electrical conductivity, low surface area and insufficient mechanical strength/elasticity; the interconnected self-supported reproducible 3D graphenes remain unavailable. Here we report a sugar-blowing approach based on a polymeric predecessor to synthesize a 3D graphene bubble network. The bubble network consists of mono- or few-layered graphitic membranes that are tightly glued, rigidly fixed and spatially scaffolded by micrometre-scale graphitic struts. Such a topological configuration provides intimate structural interconnectivities, freeway for electron/phonon transports, huge accessible surface area, as well as robust mechanical properties. The graphene network thus overcomes the drawbacks of presently available 3D graphene products and opens up a wide horizon for diverse practical usages, for example, high-power high-energy electrochemical capacitors, as highlighted in this work.

  20. Anomalous Doppler effects in bulk phononic crystal

    International Nuclear Information System (INIS)

    Cai Feiyan; He Zhaojian; Zhang Anqi; Ding Yiqun; Liu Zhengyou

    2010-01-01

    Doppler effects in simple cubic phononic crystal are studied theoretically and numerically. In addition to observing Doppler shifts from a moving source's frequencies inside the gap, we find that Doppler shifts can be multi-order, anisotropic, and the dominant order of shift depends on the band index that the source's frequency is in.

  1. One- and two-dimensional antenna arrays for microwave wireless power transfer (MWPT) systems and dual-antenna transceivers

    Science.gov (United States)

    Lin, Yo-Sheng; Hu, Chun-Hao; Chang, Chi-Ho; Tsao, Ping-Chang

    2018-06-01

    In this work, we demonstrate novel one-dimensional (1D) and two-dimensional (2D) antenna arrays for both microwave wireless power transfer (MWPT) systems and dual-antenna transceivers. The antenna array can be used as the MWPT receiving antenna of an integrated MWPT and Bluetooth (BLE) communication module (MWPT-BLE module) for smart CNC (computer numerical control) spindle incorporated with the cloud computing system SkyMars. The 2D antenna array has n rows of 1 × m 1D array, and each array is composed of multiple (m) differential feeding antenna elements. Each differential feeding antenna element is a differential feeding structure with a microstrip antenna stripe. The stripe length is shorter than one wavelength to minimise the antenna area and to prevent being excited to a high-order mode. That is, the differential feeding antenna element can suppress the even mode. The mutual coupling between the antenna elements can be suppressed, and the isolation between the receiver and the transmitter can be enhanced. An inclination angle of the main beam aligns with the broadside, and the main beam is further concentrated and shrunk at the elevation direction. Moreover, if more differential feeding antenna elements are used, antenna gain and isolation can be further enhanced. The excellent performance of the proposed antenna arrays indicates that they are suitable for both MWPT systems and dual-antenna transceivers.

  2. One-dimensional simulation for attemperator based on commissioning data of coal-fired steam power plant

    International Nuclear Information System (INIS)

    Cho, Baekhyun; Choi, Geunwon; Uruno, Yumi; Kim, Hyunseo; Chung, Jaewon; Kim, Hyojun; Lee, Kihyun

    2017-01-01

    Highlights: • An attemperator is a device to spray water into the superheated steam. • The evaporation was analyzed using the enthalpy balance from the commissioning data. • The spray atomization and its concurrent evaporation in an attemperator were physically modeled. • A simple one-dimensional simulation was conducted to verify the commissioning results. - Abstract: An attemperator is a device that is used to spray water into the superheated steam between the primary, platen, and final superheaters and the reheat lines. The goal of the attemperator is to control the temperature of the superheated steam in accordance with desired turbine-inlet temperature during both steady-state and transient operation. Because the thermowell installed at the attemperator outlet is tied back to the feedback control of the spray water, the spray water should evaporate ahead of the thermowell for accurate control of the steam temperature. In this work, the completion of the evaporation ahead of the thermowell was analyzed using the enthalpy balance from the start-up commissioning data of an 800-MW coal-fired steam power plant. In addition, the phenomena of the spray atomization and its concurrent evaporation in an attemperator were physically modeled, and a simple one-dimensional simulation was conducted to verify the analysis of the commissioning data.

  3. Three-dimensional simulation of radioactive pollutant in the atmosphere from nuclear power plant

    International Nuclear Information System (INIS)

    Buske, Daniela; Vilhena, Marco Tullio de

    2008-01-01

    In this work we report numerical simulations using the GILTT (Generalized Integral Laplace Transform Technique) approach to simulate radioactive pollutant dispersion in the Planetary Boundary Layer (PBL). To study the dispersion and the possible scenarios arising from accidental emissions, the results obtained with the GILTT method are compared with experimental data obtained at the Nuclear Power Plant of Angra dos Reis under neutral/moderately unstable conditions. Furthermore, to a better description of the wind profile for the irregular ground level terrain, we consider the wind profile as solution of the MM5 mesoscale model. The statistical indices point out a reasonable good agreement is obtained between experimental data and GILTT model. (author)

  4. Impact of the difference in power frequency on diamond-like carbon thin film coating over 3-dimensional objects

    Energy Technology Data Exchange (ETDEWEB)

    Nakaya, Masaki, E-mail: m-nakaya@kirin.co.jp [Packaging Technology Development Center, Technology Development Department, Kirin Brewery Co., Ltd., 1-17-1 Namamugi, Tsurumi-ku, Yokohama, Kanagawa 230-8682 (Japan); Shimizu, Mari [Packaging Technology Development Center, Technology Development Department, Kirin Brewery Co., Ltd., 1-17-1 Namamugi, Tsurumi-ku, Yokohama, Kanagawa 230-8682 (Japan); Uedono, Akira [Division of Applied Physics, Faculty of Pure and Applied Science, University of Tsukuba, Tsukuba, Ibaraki 305-8573 (Japan)

    2014-08-01

    With a type of capacitatively coupled plasma enhanced chemical vapor deposition (PECVD) technique, where two specially designed electrodes face to each other, the inner surface of hollow 3-dimensional objects such as poly(ethylene terephthalate) (PET) bottles can be coated with diamond-like carbon (DLC) thin film. DLC-coated PET bottles obtained with this technique have an enhanced gas barrier property, and therefore are applicable to industrial use such as for the extension of the shelf-life of contents sensitive to gas permeation. In this paper, the impact of power frequency ranging from 2.5 to 13.56 MHz was studied in order to research the behavior of plasma inside PET bottles and resultant properties. Different power frequency turned out to be influential on gas barrier property, the overall and distribution of tint, and adhesion between DLC and PET substrate. In addition, positron annihilation turned out to be powerful tool for the comparison of different coating conditions because it clarifies the homogeneity of DLC thin films through providing information on overall structure and thickness of them. These findings can be used for the optimization not only in the beverage PET bottle application, but also in other capacitatively coupled PECVD devices. - Highlights: • We demonstrated an effective methodology for the homogeneity of thin films. • We described the influence of power frequency on plasma and resultant thin film. • Diamond-like carbon coated on poly(ethylene terephthalate) bottles was used. • Different frequency provided homogenous thin films based on the above methodology. • For the industrial performance of the bottles, optimization was found at 6 MHz.

  5. Impact of the difference in power frequency on diamond-like carbon thin film coating over 3-dimensional objects

    International Nuclear Information System (INIS)

    Nakaya, Masaki; Shimizu, Mari; Uedono, Akira

    2014-01-01

    With a type of capacitatively coupled plasma enhanced chemical vapor deposition (PECVD) technique, where two specially designed electrodes face to each other, the inner surface of hollow 3-dimensional objects such as poly(ethylene terephthalate) (PET) bottles can be coated with diamond-like carbon (DLC) thin film. DLC-coated PET bottles obtained with this technique have an enhanced gas barrier property, and therefore are applicable to industrial use such as for the extension of the shelf-life of contents sensitive to gas permeation. In this paper, the impact of power frequency ranging from 2.5 to 13.56 MHz was studied in order to research the behavior of plasma inside PET bottles and resultant properties. Different power frequency turned out to be influential on gas barrier property, the overall and distribution of tint, and adhesion between DLC and PET substrate. In addition, positron annihilation turned out to be powerful tool for the comparison of different coating conditions because it clarifies the homogeneity of DLC thin films through providing information on overall structure and thickness of them. These findings can be used for the optimization not only in the beverage PET bottle application, but also in other capacitatively coupled PECVD devices. - Highlights: • We demonstrated an effective methodology for the homogeneity of thin films. • We described the influence of power frequency on plasma and resultant thin film. • Diamond-like carbon coated on poly(ethylene terephthalate) bottles was used. • Different frequency provided homogenous thin films based on the above methodology. • For the industrial performance of the bottles, optimization was found at 6 MHz

  6. Benzothienobenzothiophene-Based Molecular Conductors: High Conductivity, Large Thermoelectric Power Factor, and One-Dimensional Instability.

    Science.gov (United States)

    Kiyota, Yasuhiro; Kadoya, Tomofumi; Yamamoto, Kaoru; Iijima, Kodai; Higashino, Toshiki; Kawamoto, Tadashi; Takimiya, Kazuo; Mori, Takehiko

    2016-03-23

    On the basis of an excellent transistor material, [1]benzothieno[3,2-b][1]benzothiophene (BTBT), a series of highly conductive organic metals with the composition of (BTBT)2XF6 (X = P, As, Sb, and Ta) are prepared and the structural and physical properties are investigated. The room-temperature conductivity amounts to 4100 S cm(-1) in the AsF6 salt, corresponding to the drift mobility of 16 cm(2) V(-1) s(-1). Owing to the high conductivity, this salt shows a thermoelectric power factor of 55-88 μW K(-2) m(-1), which is a large value when this compound is regarded as an organic thermoelectric material. The thermoelectric power and the reflectance spectrum indicate a large bandwidth of 1.4 eV. These salts exhibit an abrupt resistivity jump under 200 K, which turns to an insulating state below 60 K. The paramagnetic spin susceptibility, and the Raman and the IR spectra suggest 4kF charge-density waves as an origin of the low-temperature insulating state.

  7. High power microwave source with a three dimensional printed metamaterial slow-wave structure

    International Nuclear Information System (INIS)

    French, David M.; Shiffler, Don

    2016-01-01

    For over the last decade, the concept of metamaterials has led to new approaches for considering the interaction of radiation with complex structures. However, practical manifestations of such a device operating at high power densities have proven difficult to achieve due to the resonant nature of metamaterials and the resultant high electric fields, which place severe constraints on manufacturing the slow wave structures. In this paper, we describe the first experimental manifestation of a high power microwave device utilizing a metallic slow wave structure (metamaterial-like) fabricated using additive manufacturing. The feasibility of utilizing additive manufacturing as a technique for building these relatively complicated structures has thus been demonstrated. The MW class microwave source operates in the C-band and shows frequency tunablility with electron beam voltage. The basic electromagnetic characteristics of this device, the construction using additive manufacturing, and the basic performance as a microwave oscillator are considered. Due to the tunable nature of the device, it shows promise not only as an oscillator but also as a microwave amplifier. Therefore, the dispersive characteristics and a discussion of the anticipated gain is included as it relates to an amplifier configuration.

  8. High power microwave source with a three dimensional printed metamaterial slow-wave structure

    Energy Technology Data Exchange (ETDEWEB)

    French, David M.; Shiffler, Don [Air Force Research Laboratory, Directed Energy Directorate, Albuquerque, New Mexico 871117 (United States)

    2016-05-15

    For over the last decade, the concept of metamaterials has led to new approaches for considering the interaction of radiation with complex structures. However, practical manifestations of such a device operating at high power densities have proven difficult to achieve due to the resonant nature of metamaterials and the resultant high electric fields, which place severe constraints on manufacturing the slow wave structures. In this paper, we describe the first experimental manifestation of a high power microwave device utilizing a metallic slow wave structure (metamaterial-like) fabricated using additive manufacturing. The feasibility of utilizing additive manufacturing as a technique for building these relatively complicated structures has thus been demonstrated. The MW class microwave source operates in the C-band and shows frequency tunablility with electron beam voltage. The basic electromagnetic characteristics of this device, the construction using additive manufacturing, and the basic performance as a microwave oscillator are considered. Due to the tunable nature of the device, it shows promise not only as an oscillator but also as a microwave amplifier. Therefore, the dispersive characteristics and a discussion of the anticipated gain is included as it relates to an amplifier configuration.

  9. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    Energy Technology Data Exchange (ETDEWEB)

    Delgado Oliva, F., E-mail: frandelgol@hotmail.com; Arlandis Guzman, S.; Bonillo García, M.; Broseta Rico, E.; Boronat Tormo, F.

    2016-10-15

    Objectives: To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. Material and methods: A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4–20 ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Results: Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3 ± 7.01 years (95% CI, 63.75–64.70); mean total PSA was 8.9 ± 3.61 ng/mL (95% CI, 8.67–9.13) and the mean prostate volume was 56.2 ± 29 cc (95% CI, 54.2–58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16

  10. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    Science.gov (United States)

    Delgado Oliva, F; Arlandis Guzman, S; Bonillo García, M; Broseta Rico, E; Boronat Tormo, F

    2016-10-01

    To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4-20ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3±7.01years (95% CI, 63.75-64.70); mean total PSA was 8.9±3.61ng/mL (95% CI, 8.67-9.13) and the mean prostate volume was 56.2±29cc (95% CI, 54.2-58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16% vs. 35%), and stage cT2 (43.5% vs. 66.6%), with a p value0

  11. Diagnostic performance of power doppler and ultrasound contrast agents in early imaging-based diagnosis of organ-confined prostate cancer: Is it possible to spare cores with contrast-guided biopsy?

    International Nuclear Information System (INIS)

    Delgado Oliva, F.; Arlandis Guzman, S.; Bonillo García, M.; Broseta Rico, E.; Boronat Tormo, F.

    2016-01-01

    Objectives: To evaluate the diagnostic performance of gray scale transrectal ultrasound-B-mode US (BMUS), power Doppler (PDUS), and sonographic contrast (CEUS) in early imaging-based diagnosis of localized prostate cancer (PCa) and to compare the diagnostic profitability of randomized biopsy (RB), US-targeted prostate biopsy by means of PDUS and CEUS. Material and methods: A single-center, prospective, transversal, epidemiological study was conducted from January 2010 to January 2014. We consecutively included patients who an imaging study of the prostate with BMUS, PDUS, and CEUS was performed, followed by prostate biopsy due to clinical suspicion of prostate cancer (PSA 4–20 ng/mL and/or rectal exam suggestive of malignancy). The diagnostic performance of BMUS, PDUS, and CEUS was determined by calculating the Sensitivity (S), Specificity (Sp), Predictive values (PV), and diagnostic odds ratio (OR) of the diagnosis tests and, for these variables, in the population general and based on their clinical stage according to rectal exam (cT1 and cT2). PCa detection rates determined by means of a randomized 10-core biopsy scheme were compared with detection rates of CEUS-targeted (SonoVue) 2-core biopsies. Results: Of the initial 984 patients, US contrast SonoVue was administered to 179 (18.2%). The PCa detection rate by organ of BMUS/PDUS in the global population was 38% versus 43% in the subpopulation with CEUS. The mean age of the patients was 64.3 ± 7.01 years (95% CI, 63.75–64.70); mean total PSA was 8.9 ± 3.61 ng/mL (95% CI, 8.67–9.13) and the mean prostate volume was 56.2 ± 29 cc (95% CI, 54.2–58.1). The detection rate by organ of targeted biopsy with BMUS, PDUS, and CEUS were as follows: Global population (10.6, 8.2, 24.5%), stage cT1 (5.6, 4.2, 16.4%), and stage cT2 (32.4, 22.3, 43.5%). Comparing the detection rates of the CEUS-targeted biopsy and randomized biopsy, the following results were obtained: Global population (24.5% vs. 41.8%), stage cT1 (16

  12. Durability-enhanced two-dimensional hole gas of C-H diamond surface for complementary power inverter applications.

    Science.gov (United States)

    Kawarada, Hiroshi; Yamada, Tetsuya; Xu, Dechen; Tsuboi, Hidetoshi; Kitabayashi, Yuya; Matsumura, Daisuke; Shibata, Masanobu; Kudo, Takuya; Inaba, Masafumi; Hiraiwa, Atsushi

    2017-02-20

    Complementary power field effect transistors (FETs) based on wide bandgap materials not only provide high-voltage switching capability with the reduction of on-resistance and switching losses, but also enable a smart inverter system by the dramatic simplification of external circuits. However, p-channel power FETs with equivalent performance to those of n-channel FETs are not obtained in any wide bandgap material other than diamond. Here we show that a breakdown voltage of more than 1600 V has been obtained in a diamond metal-oxide-semiconductor (MOS) FET with a p-channel based on a two-dimensional hole gas (2DHG). Atomic layer deposited (ALD) Al 2 O 3 induces the 2DHG ubiquitously on a hydrogen-terminated (C-H) diamond surface and also acts as both gate insulator and passivation layer. The high voltage performance is equivalent to that of state-of-the-art SiC planar n-channel FETs and AlGaN/GaN FETs. The drain current density in the on-state is also comparable to that of these two FETs with similar device size and V B .

  13. Three dimensional considerations in thermal-hydraulics of helical cruciform fuel rods for LWR power uprates

    Energy Technology Data Exchange (ETDEWEB)

    Shirvan, Koroush, E-mail: kshirvan@mit.edu; Kazimi, Mujid S.

    2014-04-01

    Highlights: • We benchmarked the 4 × 4 helical cruciform fuel (HCF) bundle pressure drop experimental data with CFD. • We also benchmarked the 4 × 4 HCF mixing experimental data with CFD. • We derived new friction factors for PWR and BWR designs at PWR and BWR operating conditions from CFD. • We showed the importance of modeling the 3D conduction in HCF in steady state and transient conditions. - Abstract: In order to increase the power density of current and new light water reactor designs, the helical cruciform fuel (HCF) rods have been proposed. The HCF rod is equivalent to a thin cylindrical rod, with 4 fuel containing vanes, wrapped around it. The HCF rods increase the surface area to volume ratio of the fuel and enhance the inter-subchannel mixing due to their helical shape. The rods do not need supporting grids, as they are packed to periodically contact their neighbors along the flow direction, enabling a higher power density in the core. The HCF rods were reported to have the potential to uprate existing PWRs by 45% and BWRs by 20%. In order to quantify the mixing behavior of the HCF rods based on their twist pitch, experiments were previously performed at atmospheric pressures with single phase water in a 4 by 4 HCF and cylindrical rod bundles. In this paper, the experimental results on pressure drop and mixing are benchmarked with computational fluid dynamic (CFD) using steady state the Reynolds average Navier–Stokes (RANS) turbulence model. The sensitivity of the CFD approach to computational domain, mesh size, mesh shape and RANS turbulence models are examined against the experimental conditions. Due to the refined radial velocity profile from the HCF rods twist, the turbulence models showed little sensitivity to the domain. Based on the CFD simulations, the total pressure drops under the PWR and BWR conditions are expected to be about 10% higher than the values previously reported solely from an empirical correlation based on the

  14. Gamma-ray induced doppler broadening

    International Nuclear Information System (INIS)

    Robinson, S.J.

    1992-01-01

    The ultra high resolving power of the GAMS4 double-flat crystal spectrometer (M.S. Dewey et al Nucl. Instrum. Methods A 284 (1989) 151.) has been used to observe the Doppler broadening of gamma-rays emitted by nuclei recoiling at speeds as low as 10 -6 c. Such recoils may be induced by the previous emission of gamma-radiation following thermal neutron capture. If the population mechanism of an excited state is known (or can be approximated) and the slowing down mechanism can be modeled, then this technique can be used to extract the lifetime of excited nuclear states. The combination of this technique and the neutron capture reaction allows the study of states which cannot necessarily be accessed by other means. This has allowed the resolution of a number of long standing questions in low-spin nuclear structure. The basis of the technique is discussed and a number of examples given

  15. Spontaneous Mechanical Buckling in Two-Dimensional Materials: A Power Source for Ambient Vibration Energy Harvesters

    Science.gov (United States)

    Thibado, Paul; Kumar, Pradeep; Singh, Surendra

    Internet-of-Things (IoT) is projected to become a multi-trillion-dollar market, but most applications cannot afford replacing batteries on such a large scale, driving the need for battery alternatives. We recently discovered that freestanding graphene membranes are in perpetual motion when held at room temperature. Surprisingly, the random up-down motion of the membrane does not follow classical Brownian motion, but instead is super-diffusive at short times and sub-diffusive at long times. Furthermore, the velocity probability distribution function is non-Gaussian and follows the heavy-tailed Cauchy-Lorentz distribution, consistent with Lévy flights. Molecular dynamics simulations reveal that mechanical buckling is spontaneously occurring, and that this is the mechanism responsible for the anomalous movement. Bucking in this system occurs when the local material suddenly flips from concave to convex. The higher kinetic energy associated with this motion is derived from the surrounding thermal waste heat, and it may be converted into an electrical current and used as the active component of small power generators known as ambient vibration energy harvesters. thibado@uark.edu.

  16. Ergotamine-derived dopamine agonists and left ventricular function in Parkinson patients: systolic and diastolic function studied by conventional echocardiography, tissue Doppler imaging, and two-dimensional speckle tracking.

    Science.gov (United States)

    Rasmussen, Vibeke Guldbrand; Poulsen, Steen Hvitfeldt; Dupont, Erik; Ostergaard, Karen; Safikhany, Gholamhossein; Egeblad, Henrik

    2008-11-01

    Ergot-derived dopamine agonists (EDDA) induce fibrotic heart valve disease. We aimed to investigate whether EDDA treatment also affects left ventricular (LV) function. Myocardial function was evaluated in 110 Parkinson patients [mean age (63.4 +/- 9.0 years)] treated for at least 6 months with either EDDA (n = 71) or non-EDDA (n = 39). LV ejection fraction did not differ between EDDA and non-EDDA patients [63 +/- 4% vs. 65 +/- 4% (ns)]. There was no difference in prevalence of diastolic dysfunction between EDDA and non-EDDA patients [7% vs. 8% (ns)]. Finally, averaged LV systolic myocardial strain and longitudinal displacement analysed by means of two-dimensional speckle tracking showed no difference between EDDA and non-EDDA patients [strain: 19 +/- 3% vs. 19 +/- 2% (ns) and longitudinal displacement: 12 +/- 2 mm vs. 12 +/- 2 mm (ns)]. Elevated p-NT-proBNP was found in 38% of EDDA patients and in 59% of non-EDDA patients (ns). In contrast to the well-established association between EDDA treatment and valvular fibrosis, EDDA did not have a detectable adverse impact on myocardial systolic and diastolic function.

  17. Constructing and analysis of soliton-like solutions of (1 + 1), (2 + 1), (3 + 1)-dimensional Schrodinger equations with the third power nonlinearity law

    International Nuclear Information System (INIS)

    Zhestkov, S.V.; Romanenko, A.A.

    2009-01-01

    The problem of existence of soliton-like solutions of (1+1), (2+1), (3+1)-dimensional Schrodinger equations with the third power nonlinearity law is investigated. The numerical-analytical method of constructing solitons is developed. (authors)

  18. Applications of Doppler-free saturation spectroscopy for edge physics studies (invited)

    Energy Technology Data Exchange (ETDEWEB)

    Martin, E. H., E-mail: martineh@ornl.gov; Caughman, J. B. O.; Isler, R. C.; Bell, G. L. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Zafar, A. [Department of Nuclear Engineering, North Carolina State University, Raleigh, North Carolina 27695 (United States)

    2016-11-15

    Doppler-free saturation spectroscopy provides a very powerful method to obtain detailed information about the electronic structure of the atom through measurement of the spectral line profile. This is achieved through a significant decrease in the Doppler broadening and essentially an elimination of the instrument broadening inherent to passive spectroscopic techniques. In this paper we present the technique and associated physics of Doppler-free saturation spectroscopy in addition to how one selects the appropriate transition. Simulations of H{sub δ} spectra are presented to illustrate the increased sensitivity to both electric field and electron density measurements.

  19. Narrowing of electromagnetically induced transparency resonance in a Doppler-broadened medium

    International Nuclear Information System (INIS)

    Javan, Ali; Kocharovskaya, Olga; Lee Hwang; Scully, Marlan O.

    2002-01-01

    We derive an analytic expression for the linewidth of electromagnetically induced transparency (EIT) resonance in a Doppler-broadened system. It is shown here that for relatively low intensity of the driving field the EIT linewidth is proportional to the square root of intensity and is independent of the Doppler width, similar to the laser-induced line narrowing effect described by Feld and Javan. In the limit of high intensity we recover the usual power-broadening case where the EIT linewidth is proportional to the intensity and inversely proportional to the Doppler width

  20. PRELIMINARY COUPLING OF THE MONTE CARLO CODE OPENMC AND THE MULTIPHYSICS OBJECT-ORIENTED SIMULATION ENVIRONMENT (MOOSE) FOR ANALYZING DOPPLER FEEDBACK IN MONTE CARLO SIMULATIONS

    Energy Technology Data Exchange (ETDEWEB)

    Matthew Ellis; Derek Gaston; Benoit Forget; Kord Smith

    2011-07-01

    In recent years the use of Monte Carlo methods for modeling reactors has become feasible due to the increasing availability of massively parallel computer systems. One of the primary challenges yet to be fully resolved, however, is the efficient and accurate inclusion of multiphysics feedback in Monte Carlo simulations. The research in this paper presents a preliminary coupling of the open source Monte Carlo code OpenMC with the open source Multiphysics Object-Oriented Simulation Environment (MOOSE). The coupling of OpenMC and MOOSE will be used to investigate efficient and accurate numerical methods needed to include multiphysics feedback in Monte Carlo codes. An investigation into the sensitivity of Doppler feedback to fuel temperature approximations using a two dimensional 17x17 PWR fuel assembly is presented in this paper. The results show a functioning multiphysics coupling between OpenMC and MOOSE. The coupling utilizes Functional Expansion Tallies to accurately and efficiently transfer pin power distributions tallied in OpenMC to unstructured finite element meshes used in MOOSE. The two dimensional PWR fuel assembly case also demonstrates that for a simplified model the pin-by-pin doppler feedback can be adequately replicated by scaling a representative pin based on pin relative powers.

  1. One-dimensional breakdown voltage model of SOI RESURF lateral power device based on lateral linearly graded approximation

    International Nuclear Information System (INIS)

    Zhang Jun; Guo Yu-Feng; Xu Yue; Lin Hong; Yang Hui; Hong Yang; Yao Jia-Fei

    2015-01-01

    A novel one-dimensional (1D) analytical model is proposed for quantifying the breakdown voltage of a reduced surface field (RESURF) lateral power device fabricated on silicon on an insulator (SOI) substrate. We assume that the charges in the depletion region contribute to the lateral PN junctions along the diagonal of the area shared by the lateral and vertical depletion regions. Based on the assumption, the lateral PN junction behaves as a linearly graded junction, thus resulting in a reduced surface electric field and high breakdown voltage. Using the proposed model, the breakdown voltage as a function of device parameters is investigated and compared with the numerical simulation by the TCAD tools. The analytical results are shown to be in fair agreement with the numerical results. Finally, a new RESURF criterion is derived which offers a useful scheme to optimize the structure parameters. This simple 1D model provides a clear physical insight into the RESURF effect and a new explanation on the improvement in breakdown voltage in an SOI RESURF device. (paper)

  2. Scaling characteristics of one-dimensional fractional diffusion processes in the presence of power-law distributed random noise.

    Science.gov (United States)

    Nezhadhaghighi, Mohsen Ghasemi

    2017-08-01

    Here, we present results of numerical simulations and the scaling characteristics of one-dimensional random fluctuations with heavy-tailed probability distribution functions. Assuming that the distribution function of the random fluctuations obeys Lévy statistics with a power-law scaling exponent, we investigate the fractional diffusion equation in the presence of μ-stable Lévy noise. We study the scaling properties of the global width and two-point correlation functions and then compare the analytical and numerical results for the growth exponent β and the roughness exponent α. We also investigate the fractional Fokker-Planck equation for heavy-tailed random fluctuations. We show that the fractional diffusion processes in the presence of μ-stable Lévy noise display special scaling properties in the probability distribution function (PDF). Finally, we numerically study the scaling properties of the heavy-tailed random fluctuations by using the diffusion entropy analysis. This method is based on the evaluation of the Shannon entropy of the PDF generated by the random fluctuations, rather than on the measurement of the global width of the process. We apply the diffusion entropy analysis to extract the growth exponent β and to confirm the validity of our numerical analysis.

  3. Estimation of the two-dimensional power spectral density of spatial fluctuation in terrestrial gamma-ray dose rate

    International Nuclear Information System (INIS)

    Minato, Susumu

    2000-01-01

    The multiple regression analysis done for 50 sets of data of natural terrestrial gamma-ray dose rates collected from different sites of the world led to an empirical formula for the variance of the data as a function of mean value and area. The mean values and areas studied in this paper range from 10 to 100 (nGy/h) and from 10 -3 to 10 7 (km 2 ), respectively. For an isotropic field of fluctuation, a two-dimensional power spectral density (2D PSD) was derived theoretically from the above mentioned empirical formula in a form of S(k)=0.952 x 10 -3 m 2.02 k -2.36 , where k (cycles/km) and m (nGy/h) are the wave number and the mean, respectively. The validity of the estimated 2D PSD was confirmed by comparing with PSDs obtained by the following two methods. One is the spatial auto-correlation analysis for several sets of randomly distributed 2D data consisting of more than 170 samples taken through ground surveys. The other is the direct 2D Fourier transform for two sets of 100 x 100 data matrix picked up from a dose rate map produced through airborne surveys. (author)

  4. Three-dimensional strutted graphene grown by substrate-free sugar blowing for high-power-density supercapacitors

    Science.gov (United States)

    Wang, Xuebin; Zhang, Yuanjian; Zhi, Chunyi; Wang, Xi; Tang, Daiming; Xu, Yibin; Weng, Qunhong; Jiang, Xiangfen; Mitome, Masanori; Golberg, Dmitri; Bando, Yoshio

    2013-01-01

    Three-dimensional graphene architectures in the macroworld can in principle maintain all the extraordinary nanoscale properties of individual graphene flakes. However, current 3D graphene products suffer from poor electrical conductivity, low surface area and insufficient mechanical strength/elasticity; the interconnected self-supported reproducible 3D graphenes remain unavailable. Here we report a sugar-blowing approach based on a polymeric predecessor to synthesize a 3D graphene bubble network. The bubble network consists of mono- or few-layered graphitic membranes that are tightly glued, rigidly fixed and spatially scaffolded by micrometre-scale graphitic struts. Such a topological configuration provides intimate structural interconnectivities, freeway for electron/phonon transports, huge accessible surface area, as well as robust mechanical properties. The graphene network thus overcomes the drawbacks of presently available 3D graphene products and opens up a wide horizon for diverse practical usages, for example, high-power high-energy electrochemical capacitors, as highlighted in this work. PMID:24336225

  5. Development of a three dimensional elastic plastic analysis system for the integrity evaluation of nuclear power plant components

    International Nuclear Information System (INIS)

    Huh, Nam Su; Im, Chang Ju; Kim, Young Jin; Pyo, Chang Ryul; Park, Chi Yong

    2000-01-01

    In order to evaluate the integrity of nuclear power plant components, the analysis based on fracture mechanics is crucial. For this purpose, finite element method is popularly used to obtain J-integral. However, it is time consuming to design the finite element model of a cracked structure. Also, the J-integral should by verified by alternative methods since it may differ depending on the calculation method. The objective of this paper is to develop a three-dimensional elastic-plastic J-integral analysis system which is named as EPAS program. The EPAS program consists of an automatic mesh generator for a through-wall crack and a surface crack, a solver based on ABAQUS program, and a J-integral calculation program which provides DI (Domain Integral) and EDI (Equivalent Domain Integral) based J-integral calculation. Using the EPAS program, an optimized finite element model for a cracked structure can be generated and corresponding J-integral can be obtained subsequently

  6. Scaling characteristics of one-dimensional fractional diffusion processes in the presence of power-law distributed random noise

    Science.gov (United States)

    Nezhadhaghighi, Mohsen Ghasemi

    2017-08-01

    Here, we present results of numerical simulations and the scaling characteristics of one-dimensional random fluctuations with heavy-tailed probability distribution functions. Assuming that the distribution function of the random fluctuations obeys Lévy statistics with a power-law scaling exponent, we investigate the fractional diffusion equation in the presence of μ -stable Lévy noise. We study the scaling properties of the global width and two-point correlation functions and then compare the analytical and numerical results for the growth exponent β and the roughness exponent α . We also investigate the fractional Fokker-Planck equation for heavy-tailed random fluctuations. We show that the fractional diffusion processes in the presence of μ -stable Lévy noise display special scaling properties in the probability distribution function (PDF). Finally, we numerically study the scaling properties of the heavy-tailed random fluctuations by using the diffusion entropy analysis. This method is based on the evaluation of the Shannon entropy of the PDF generated by the random fluctuations, rather than on the measurement of the global width of the process. We apply the diffusion entropy analysis to extract the growth exponent β and to confirm the validity of our numerical analysis.

  7. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  8. Measurement of ventricular function using Doppler ultrasound

    International Nuclear Information System (INIS)

    Teague, S.M.

    1986-01-01

    Doppler has wide application in the evaluation of valvular heart disease. The need to know ventricular function is a much more common reason for an echocardiographic evaluation. Interestingly, Doppler examinations can assess ventricular function from many perspectives. Description of ventricular function entails measurement of the timing, rate and volume of ventricular filling and ejection. Doppler ultrasound examination reveals all of these aspects of ventricular function noninvasively, simply, and without great expense or radiation exposure, as described in this chapter

  9. Direct Doppler auscultation of the carotid arteries

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The results of the carotid Doppler examinations and contrast arteriograms are presented. The overall sensitivity of the carotid Doppler examinations in detecting severe stenosis or occlusion of the carotid artery was 92%. The Doppler studies correctly differentiated these two conditions in 84% of the diseased vessels. In carotid arteries with stenosis greater than or equal to 50%, the sensitivity of the Doppler examinations was 90%, and these studies suggested stenosis in all but two of the 36 abnormal examinations. In two patent carotids with greater than 90% stenosis, a signal could not be elicited, presumably because of the low blood flow through the severely stenotic segment

  10. ZEEMAN DOPPLER MAPS: ALWAYS UNIQUE, NEVER SPURIOUS?

    Energy Technology Data Exchange (ETDEWEB)

    Stift, Martin J.; Leone, Francesco [Armagh Observatory, College Hill, Armagh BT61 9DG (United Kingdom)

    2017-01-01

    Numerical models of atomic diffusion in magnetic atmospheres of ApBp stars predict abundance structures that differ from the empirical maps derived with (Zeeman) Doppler mapping (ZDM). An in-depth analysis of this apparent disagreement investigates the detectability by means of ZDM of a variety of abundance structures, including (warped) rings predicted by theory, but also complex spot-like structures. Even when spectra of high signal-to-noise ratio are available, it can prove difficult or altogether impossible to correctly recover shapes, positions, and abundances of a mere handful of spots, notwithstanding the use of all four Stokes parameters and an exactly known field geometry; the recovery of (warped) rings can be equally challenging. Inversions of complex abundance maps that are based on just one or two spectral lines usually permit multiple solutions. It turns out that it can by no means be guaranteed that any of the regularization functions in general use for ZDM (maximum entropy or Tikhonov) will lead to a true abundance map instead of some spurious one. Attention is drawn to the need for a study that would elucidate the relation between the stratified, field-dependent abundance structures predicted by diffusion theory on the one hand, and empirical maps obtained by means of “canonical” ZDM, i.e., with mean atmospheres and unstratified abundances, on the other hand. Finally, we point out difficulties arising from the three-dimensional nature of the atomic diffusion process in magnetic ApBp star atmospheres.

  11. Glare Spot Phase Doppler Anemometry

    Science.gov (United States)

    Hespel, Camille; Ren, Kuanfang; Gréhan, Gérard; Onofri, Fabrice

    2007-06-01

    The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index would be also interesting since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemometry which uses two large beams. In this case, the images of the particle formed by the reflected and refracted light, known as glare spots, are separated in space. When a particle passes in the probe volume, the two parts in a signal obtained by a detector in forward direction are then separated in time. If two detectors are used the phase differences between two signals, the distance and the intensity ratio of reflected and refracted parts can be obtained and they provide rich information about the particle diameter and its refractive index, as well as its velocity. This paper is devoted to the numerical study of such a configuration with two theoretical models: geometrical optics and rigorous electromagnetism solution.

  12. Doppler broadening measurements in FRX-C/LSM

    International Nuclear Information System (INIS)

    Baron, M.H.; Chrien, R.E.

    1989-01-01

    Measurements obtained in situ during field reversed configuration (FRC) formation show that the Doppler broadening ion temperature T CV is larger by a factor of two or more than the ion temperature T i derived from pressure balance and Thomson scattering. After a time comparable to an ion-ion equilibrium time, T CV and T i come into agreement with each other. An exception to this picture occurs in the lowest fill pressure condition (2 mtorr), for which T CV > T i is maintained throughout the FRC lifetime. Earlier Doppler broadening measurements in FRX-B and FRX-C also showed persistent, anomalously high T CV at low fill pressure. The initially high values of T CV are probably caused by convective motion generated by the radial implosion. The low fill pressure results suggest an enhanced ohmic power input to the carbon ions. 7 refs., 3 figs

  13. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  14. The role of Doppler ultrasonography in the evaluation of the renal function

    International Nuclear Information System (INIS)

    Krasteva, R.; Kiperova, B.; Andreev, E.; Kostadinova, I.; Petrov, T.; Hadjidekov, V.; Simeonova, A.

    2008-01-01

    The purpose of the study was to evaluate Doppler ultrasonography in the detection of the renal function. Sixty six patients with unilateral kidney changes were enrolled in this prospective study. 16 had hypoplastic kidney, 24 had hypofunctioned kidney and 26 had afunctioned kidney. 15 healthy potential donors were controls. A dynamic renal scintigraphy was performed with 74-111 MBq 99mTc-MAG3. The Color, Pulsed and Power Doppler were performed. The Vp and δVp derived from the spectrum of the segmental arteries were measured during Pulsed Doppler examination. There are not any difference between kidneys of health and hypoplastic kidneys on color and Power Doppler. The hypofunctioning kidneys had reduced blood flow and afunctioning kidneys had markedly reduced blood flow. The Vp of donors (48.8±7.6) and Vp of hypoplastic kidneys (49.9±4.8) were significantly higher compared to Vp of hypofunctioning kidneys (31.6±10.0) and to Vp of afunctioning kidneys (26.6±9.1), (p 14.5 cm/s in 93%, and from hypofunctioning kidney by delta Vp>10.5 cm/s in 87%. The Doppler ultrasonography is very useful in the evaluation of renal function. The changes of the Doppler parameters accurately marked the loss of function which can not be detected by elevation of the creatinine level. (authors)

  15. Clinical study of color Doppler sonography in Graves' disease blood flow changes after thyroid arteries embolization

    International Nuclear Information System (INIS)

    Zhuang Wenquan; Li Weiduo; Yang Jianyong; Chen Wei; Huang Yonghui; Guo Wenbo; Li Jiaping

    2003-01-01

    Objective: To study the color doppler image characteristics of thyroid arteries pre- and post-interventional procedure and to assess the clinical efficacy in Gnaves' disease. Methods: 11 from 31 patients diagnosed as Graves' disease undertaken thyroid arteries embolization, were analyzed. Color Doppler sonography was applied to monitor the pre-and post- procedure thyroid size and diameters of thyroid arteries. Power Doppler was used to detect the Vmax, Vmin, RI and blood flow. Results: After thyroid arteries embolization, the size and vascularity of thyroids were reduced. The thyroid arteries showed shrinkage and stoppage blood flow at the embolized site. The changes of RI, blood parameters of Vmax, Vmin and diameters of the thyroid arteries pre- and post-procedure turned out to be statistically significant for clinical restriction. Conclusion: The color Doppler sonography plays an important role for preoperative diagnosis and predicting the prognosis

  16. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR......After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  17. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  18. 1-Dimensional simulation of thermal annealing in a commercial nuclear power plant reactor pressure vessel wall section

    International Nuclear Information System (INIS)

    Nakos, J.T.; Rosinski, S.T.; Acton, R.U.

    1994-11-01

    The objective of this work was to provide experimental heat transfer boundary condition and reactor pressure vessel (RPV) section thermal response data that can be used to benchmark computer codes that simulate thermal annealing of RPVS. This specific protect was designed to provide the Electric Power Research Institute (EPRI) with experimental data that could be used to support the development of a thermal annealing model. A secondary benefit is to provide additional experimental data (e.g., thermal response of concrete reactor cavity wall) that could be of use in an annealing demonstration project. The setup comprised a heater assembly, a 1.2 in x 1.2 m x 17.1 cm thick [4 ft x 4 ft x 6.75 in] section of an RPV (A533B ferritic steel with stainless steel cladding), a mockup of the open-quotes mirrorclose quotes insulation between the RPV and the concrete reactor cavity wall, and a 25.4 cm [10 in] thick concrete wall, 2.1 in x 2.1 in [10 ft x 10 ft] square. Experiments were performed at temperature heat-up/cooldown rates of 7, 14, and 28 degrees C/hr [12.5, 25, and 50 degrees F/hr] as measured on the heated face. A peak temperature of 454 degrees C [850 degrees F] was maintained on the heated face until the concrete wall temperature reached equilibrium. Results are most representative of those RPV locations where the heat transfer would be 1-dimensional. Temperature was measured at multiple locations on the heated and unheated faces of the RPV section and the concrete wall. Incident heat flux was measured on the heated face, and absorbed heat flux estimates were generated from temperature measurements and an inverse heat conduction code. Through-wall temperature differences, concrete wall temperature response, heat flux absorbed into the RPV surface and incident on the surface are presented. All of these data are useful to modelers developing codes to simulate RPV annealing

  19. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  20. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  1. Muscle activity characterization by laser Doppler Myography

    Science.gov (United States)

    Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Primo Tomasini, Enrico

    2013-09-01

    Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin.

  2. Muscle activity characterization by laser Doppler Myography

    International Nuclear Information System (INIS)

    Scalise, Lorenzo; Casaccia, Sara; Marchionni, Paolo; Ercoli, Ilaria; Tomasini, Enrico Primo

    2013-01-01

    Electromiography (EMG) is the gold-standard technique used for the evaluation of muscle activity. This technique is used in biomechanics, sport medicine, neurology and rehabilitation therapy and it provides the electrical activity produced by skeletal muscles. Among the parameters measured with EMG, two very important quantities are: signal amplitude and duration of muscle contraction, muscle fatigue and maximum muscle power. Recently, a new measurement procedure, named Laser Doppler Myography (LDMi), for the non contact assessment of muscle activity has been proposed to measure the vibro-mechanical behaviour of the muscle. The aim of this study is to present the LDMi technique and to evaluate its capacity to measure some characteristic features proper of the muscle. In this paper LDMi is compared with standard superficial EMG (sEMG) requiring the application of sensors on the skin of each patient. sEMG and LDMi signals have been simultaneously acquired and processed to test correlations. Three parameters has been analyzed to compare these techniques: Muscle activation timing, signal amplitude and muscle fatigue. LDMi appears to be a reliable and promising measurement technique allowing the measurements without contact with the patient skin

  3. A three-dimensional numerical investigation of trapezoid baffles effect on non-isothermal reactant transport and cell net power in a PEMFC

    International Nuclear Information System (INIS)

    Perng, Shiang-Wuu; Wu, Horng-Wen

    2015-01-01

    Highlights: • We study how angle and height of trapezoid baffle affect PEMFC net power. • The jet-type, trapping, and blockage effects augment non-isothermal transport in flow channel. • Greater angles and heights of trapezoid baffles provide more reactant to the catalyst layer. • Baffles of 1.5 mm and 90° fully block flow channel to show bad heat transfer and large pressure drop. • Maximum enhancement of cell net power is 90% with baffles of 60° angle and 1.125 mm height. - Abstract: The present study performed a three-dimensional numerical simulation to observe how trapezoid baffles affect non-isothermal reactant transports and cell net power in the proton exchange membrane fuel cell (PEMFC) by the SIMPLE-C method. The geometric parameters of trapezoid baffles installed in the gas channel employed in this study include the angle and height with the same gas diffusion and catalyst layers to realize the cell net power considering the effect of liquid water formation on the fluid flow field. The cell net power is adopted to evaluate the real enhancement of cell performance due to the additional pumping power induced by the pressure loss through the PEMFC. The results illustrated that compared with traditional gas channel without baffles, the novel gas channel with trapezoid baffles, whose angle is 60° and height is 1.125 mm, enhances the cell net power best by approximately 90% among all trapezoid baffle designs

  4. Doppler Velocity Signatures of Idealized Elliptical Vortices

    Directory of Open Access Journals (Sweden)

    Wen-Chau Lee

    2006-01-01

    Full Text Available Doppler radar observations have revealed a class of atmospheric vortices (tropical cyclones, tornadoes, dust devils that possess elliptical radar reflectivity signatures. One famous example is Typhoon Herb (1996 that maintained its elliptical reflectivity structure over a 40-hour period. Theoretical work and dual-Doppler analyses of observed tropical cyclones have suggested two physical mechanisms that can explain the formation of two types of elliptical vortices observed in nature, namely, the combination of a circular vortex with either a wavenumber two vortex Rossby wave or a deformation field. The characteristics of these two types of elliptical vortices and their corresponding Doppler velocity signatures have not been previously examined.

  5. Preliminary simulation study of doppler reflectometry

    International Nuclear Information System (INIS)

    Ishii, Yuta; Hojo, Hitoshi; Yoshikawa, Masashi; Ichimura, Makoto; Haraguchi, Yusuke; Imai, Tsuyoshi; Mase, Atsushi

    2010-01-01

    A preliminary simulation study of Doppler reflectometry is performed. The simulations solve Maxwell's equations by a finite difference time domain (FDTD) code method in two dimensions. A moving corrugated metal target is used as a plasma cutoff layer to study the basic features of Doppler reflectometry. We examined the effects of the full width at half maximum (FWHM) of the electromagnetic waves and the corrugation depth of the metal target. Furthermore, the effect of a nonuniform plasma is studied using this FDTD analysis. The Doppler shift and velocity are compared with those obtained from FDTD analysis of a uniform plasma. (author)

  6. Non-Darcy Free Convection of Power-Law Fluids Over a Two-Dimensional Body Embedded in a Porous Medium

    KAUST Repository

    El-Amin, Mohamed

    2010-11-27

    A boundary layer analysis was presented to study the non-Darcy-free convection of a power-law fluid over a non-isothermal two-dimensional body embedded in a porous medium. The Ostwald-de Waele power-law model was used to characterize the non-Newtonian fluid behavior. Similarity solutions were obtained with variations in surface temperature or surface heat flux. In view of the fact that most of the non-Newtonian fluids have large Prandtl numbers, this study was directed toward such fluids. The effects of the porous medium parameters, k1 and k2, body shape parameter, m, and surface thermal variations parameter, p, as well as the power-law index, n, were examined. © 2010 Springer Science+Business Media B.V.

  7. Non-Darcy Free Convection of Power-Law Fluids Over a Two-Dimensional Body Embedded in a Porous Medium

    KAUST Repository

    El-Amin, Mohamed; Sun, Shuyu; El-Ameen, M. A.; Jaha, Y. A.; Gorla, Rama Subba Reddy

    2010-01-01

    A boundary layer analysis was presented to study the non-Darcy-free convection of a power-law fluid over a non-isothermal two-dimensional body embedded in a porous medium. The Ostwald-de Waele power-law model was used to characterize the non-Newtonian fluid behavior. Similarity solutions were obtained with variations in surface temperature or surface heat flux. In view of the fact that most of the non-Newtonian fluids have large Prandtl numbers, this study was directed toward such fluids. The effects of the porous medium parameters, k1 and k2, body shape parameter, m, and surface thermal variations parameter, p, as well as the power-law index, n, were examined. © 2010 Springer Science+Business Media B.V.

  8. Fetal Cardiac Doppler Signal Processing Techniques: Challenges and Future Research Directions

    Directory of Open Access Journals (Sweden)

    Saeed Abdulrahman Alnuaimi

    2017-12-01

    Full Text Available The fetal Doppler Ultrasound (DUS is commonly used for monitoring fetal heart rate and can also be used for identifying the event timings of fetal cardiac valve motions. In early-stage fetuses, the detected Doppler signal suffers from noise and signal loss due to the fetal movements and changing fetal location during the measurement procedure. The fetal cardiac intervals, which can be estimated by measuring the fetal cardiac event timings, are the most important markers of fetal development and well-being. To advance DUS-based fetal monitoring methods, several powerful and well-advanced signal processing and machine learning methods have recently been developed. This review provides an overview of the existing techniques used in fetal cardiac activity monitoring and a comprehensive survey on fetal cardiac Doppler signal processing frameworks. The review is structured with a focus on their shortcomings and advantages, which helps in understanding fetal Doppler cardiogram signal processing methods and the related Doppler signal analysis procedures by providing valuable clinical information. Finally, a set of recommendations are suggested for future research directions and the use of fetal cardiac Doppler signal analysis, processing, and modeling to address the underlying challenges.

  9. Code Coupling for Multi-Dimensional Core Transient Analysis

    International Nuclear Information System (INIS)

    Park, Jin-Woo; Park, Guen-Tae; Park, Min-Ho; Ryu, Seok-Hee; Um, Kil-Sup; Lee Jae-Il

    2015-01-01

    After the CEA ejection, the nuclear power of the reactor dramatically increases in an exponential behavior until the Doppler effect becomes important and turns the reactivity balance and power down to lower levels. Although this happens in a very short period of time, only few seconds, the energy generated can be very significant and cause fuel failures. The current safety analysis methodology which is based on overly conservative assumptions with the point kinetics model results in quite adverse consequences. Thus, KEPCO Nuclear Fuel(KNF) is developing the multi-dimensional safety analysis methodology to mitigate the consequences of the single CEA ejection accident. For this purpose, three-dimensional core neutron kinetics code ASTRA, sub-channel analysis code THALES, and fuel performance analysis code FROST, which have transient calculation performance, were coupled using message passing interface (MPI). This paper presents the methodology used for code coupling and the preliminary simulation results with the coupled code system (CHASER). Multi-dimensional core transient analysis code system, CHASER, has been developed and it was applied to simulate a single CEA ejection accident. CHASER gave a good prediction of multi-dimensional core transient behaviors during transient. In the near future, the multi-dimension CEA ejection analysis methodology using CHASER is planning to be developed. CHASER is expected to be a useful tool to gain safety margin for reactivity initiated accidents (RIAs), such as a single CEA ejection accident

  10. Code Coupling for Multi-Dimensional Core Transient Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin-Woo; Park, Guen-Tae; Park, Min-Ho; Ryu, Seok-Hee; Um, Kil-Sup; Lee Jae-Il [KEPCO NF, Daejeon (Korea, Republic of)

    2015-05-15

    After the CEA ejection, the nuclear power of the reactor dramatically increases in an exponential behavior until the Doppler effect becomes important and turns the reactivity balance and power down to lower levels. Although this happens in a very short period of time, only few seconds, the energy generated can be very significant and cause fuel failures. The current safety analysis methodology which is based on overly conservative assumptions with the point kinetics model results in quite adverse consequences. Thus, KEPCO Nuclear Fuel(KNF) is developing the multi-dimensional safety analysis methodology to mitigate the consequences of the single CEA ejection accident. For this purpose, three-dimensional core neutron kinetics code ASTRA, sub-channel analysis code THALES, and fuel performance analysis code FROST, which have transient calculation performance, were coupled using message passing interface (MPI). This paper presents the methodology used for code coupling and the preliminary simulation results with the coupled code system (CHASER). Multi-dimensional core transient analysis code system, CHASER, has been developed and it was applied to simulate a single CEA ejection accident. CHASER gave a good prediction of multi-dimensional core transient behaviors during transient. In the near future, the multi-dimension CEA ejection analysis methodology using CHASER is planning to be developed. CHASER is expected to be a useful tool to gain safety margin for reactivity initiated accidents (RIAs), such as a single CEA ejection accident.

  11. Development of a system for acquiring, reconstructing, and visualizing three-dimensional ultrasonic angiograms

    Science.gov (United States)

    Edwards, Warren S.; Ritchie, Cameron J.; Kim, Yongmin; Mack, Laurence A.

    1995-04-01

    We have developed a three-dimensional (3D) imaging system using power Doppler (PD) ultrasound (US). This system can be used for visualizing and analyzing the vascular anatomy of parenchymal organs. To create the 3D PD images, we acquired a series of two-dimensional PD images from a commercial US scanner and recorded the position and orientation of each image using a 3D magnetic position sensor. Three-dimensional volumes were reconstructed using specially designed software and then volume rendered for display. We assessed the feasibility and geometric accuracy of our system with various flow phantoms. The system was then tested on a volunteer by scanning a transplanted kidney. The reconstructed volumes of the flow phantom contained less than 1 mm of geometric distortion and the 3D images of the transplanted kidney depicted the segmental, arcuate, and interlobar vessels.

  12. Doppler coefficient measurements in Zebra Core 5

    International Nuclear Information System (INIS)

    Baker, A.R.; Wheeler, R.C.

    1965-11-01

    Measurements using a central hot loop in Zebra Core 5 are described. Results are given for the Doppler coefficients found in a number of assemblies with PuO 2 and 16% PuO 2 /84% depleted UO 2 pins, loaded with different combinations of steel, sodium or void pins. The mixed oxide results are in general about 20% more negative than was calculated using the FD2 data set, but agreement is good if the plutonium contributions in the calculations are omitted. The small positive Doppler coefficient calculated for Pu239 was not observed, and two measurements indicated instead a small negative effect. The Doppler effect in the mixed oxide systems was found to vary approximately as 1/T. The results from the empty loop and non-fissile assemblies indicate either a small negative Doppler effect in steel or alternatively the presence of an unexplained expansion effect. (author)

  13. Applications of Doppler in the first trimester

    International Nuclear Information System (INIS)

    Taylor, K.J.W.; Ramirez, B.; Grannum, P.

    1986-01-01

    Fifty patients have been studied by duplex Doppler US imaging in the first trimester. In normal gestations, luteal flow, characterized by a low pulsatility index (PI), can be seen in at least one ovary. Failure to detect luteal flow indicates a nonviable pregnancy. Six ectopic pregnancies demonstrated luteal flow and extrauterine heartbeat, detected by Doppler US. High PI values in the uterine artery are seen in the first trimester. Low PI values in the uterine arteries were found in patients with trophoblastic disease

  14. De-Dopplerization of Acoustic Measurements

    Science.gov (United States)

    2017-08-10

    accurate measurement of aircraft location to resample the time signal to account for the compression and expansion of acoustic wavefronts. Correcting...AFRL-RH-WP-TR-2017-0043 DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS Frank Mobley, PhD 711 HPW/RHCB Wright-Patterson AFB OH...TITLE AND SUBTITLE DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  15. Impact of bowtie filter and object position on the two-dimensional noise power spectrum of a clinical MDCT system

    Energy Technology Data Exchange (ETDEWEB)

    Gomez-Cardona, Daniel; Cruz-Bastida, Juan Pablo [Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 (United States); Li, Ke; Chen, Guang-Hong, E-mail: gchen7@wisc.edu [Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 and Department of Radiology, University of Wisconsin-Madison School of Medicine and Public Health, 600 Highland Avenue, Madison, Wisconsin 53792 (United States); Budde, Adam; Hsieh, Jiang [Department of Medical Physics, University of Wisconsin-Madison School of Medicine and Public Health, 1111 Highland Avenue, Madison, Wisconsin 53705 and GE Healthcare, 3000 N Grandview Boulevard, Waukesha, Wisconsin 53188 (United States)

    2016-08-15

    Purpose: Noise characteristics of clinical multidetector CT (MDCT) systems can be quantified by the noise power spectrum (NPS). Although the NPS of CT has been extensively studied in the past few decades, the joint impact of the bowtie filter and object position on the NPS has not been systematically investigated. This work studies the interplay of these two factors on the two dimensional (2D) local NPS of a clinical CT system that uses the filtered backprojection algorithm for image reconstruction. Methods: A generalized NPS model was developed to account for the impact of the bowtie filter and image object location in the scan field-of-view (SFOV). For a given bowtie filter, image object, and its location in the SFOV, the shape and rotational symmetries of the 2D local NPS were directly computed from the NPS model without going through the image reconstruction process. The obtained NPS was then compared with the measured NPSs from the reconstructed noise-only CT images in both numerical phantom simulation studies and experimental phantom studies using a clinical MDCT scanner. The shape and the associated symmetry of the 2D NPS were classified by borrowing the well-known atomic spectral symbols s, p, and d, which correspond to circular, dumbbell, and cloverleaf symmetries, respectively, of the wave function of electrons in an atom. Finally, simulated bar patterns were embedded into experimentally acquired noise backgrounds to demonstrate the impact of different NPS symmetries on the visual perception of the object. Results: (1) For a central region in a centered cylindrical object, an s-wave symmetry was always present in the NPS, no matter whether the bowtie filter was present or not. In contrast, for a peripheral region in a centered object, the symmetry of its NPS was highly dependent on the bowtie filter, and both p-wave symmetry and d-wave symmetry were observed in the NPS. (2) For a centered region-ofinterest (ROI) in an off-centered object, the symmetry of

  16. Impact of bowtie filter and object position on the two-dimensional noise power spectrum of a clinical MDCT system

    International Nuclear Information System (INIS)

    Gomez-Cardona, Daniel; Cruz-Bastida, Juan Pablo; Li, Ke; Chen, Guang-Hong; Budde, Adam; Hsieh, Jiang

    2016-01-01

    Purpose: Noise characteristics of clinical multidetector CT (MDCT) systems can be quantified by the noise power spectrum (NPS). Although the NPS of CT has been extensively studied in the past few decades, the joint impact of the bowtie filter and object position on the NPS has not been systematically investigated. This work studies the interplay of these two factors on the two dimensional (2D) local NPS of a clinical CT system that uses the filtered backprojection algorithm for image reconstruction. Methods: A generalized NPS model was developed to account for the impact of the bowtie filter and image object location in the scan field-of-view (SFOV). For a given bowtie filter, image object, and its location in the SFOV, the shape and rotational symmetries of the 2D local NPS were directly computed from the NPS model without going through the image reconstruction process. The obtained NPS was then compared with the measured NPSs from the reconstructed noise-only CT images in both numerical phantom simulation studies and experimental phantom studies using a clinical MDCT scanner. The shape and the associated symmetry of the 2D NPS were classified by borrowing the well-known atomic spectral symbols s, p, and d, which correspond to circular, dumbbell, and cloverleaf symmetries, respectively, of the wave function of electrons in an atom. Finally, simulated bar patterns were embedded into experimentally acquired noise backgrounds to demonstrate the impact of different NPS symmetries on the visual perception of the object. Results: (1) For a central region in a centered cylindrical object, an s-wave symmetry was always present in the NPS, no matter whether the bowtie filter was present or not. In contrast, for a peripheral region in a centered object, the symmetry of its NPS was highly dependent on the bowtie filter, and both p-wave symmetry and d-wave symmetry were observed in the NPS. (2) For a centered region-ofinterest (ROI) in an off-centered object, the symmetry of

  17. A simplified, coarse-mesh, three-dimensional diffusion scheme for calculating the gross power distribution in a boiling water reactor

    International Nuclear Information System (INIS)

    Borresen, S.

    1995-01-01

    A simplified, finite-difference diffusion scheme for a three-dimensional calculation of the gross power distribution in the core of a boiling water reactor (BWR) is presented. Results obtained in a series of one- and two-dimensional test cases indicate that this method may be of sufficient accuracy and simplicity for implementation in BWR-simulator computer programs. Computer requirements are very modest; thus, only 3N memory locations are required for in-core treatment of the inner iteration in the solution of a problem with N mesh points. The mesh width may be chosen equal to the fuel assembly pitch. Input data are in the form of conventional 2-group diffusion parameters. It is concluded that the method presented has definite advantages in comparison with the nodal coupling method. (author)

  18. Possible High Thermoelectric Power in Semiconducting Carbon Nanotubes ˜A Case Study of Doped One-Dimensional Semiconductors˜

    Science.gov (United States)

    Yamamoto, Takahiro; Fukuyama, Hidetoshi

    2018-02-01

    We have theoretically investigated the thermoelectric properties of impurity-doped one-dimensional semiconductors, focusing on nitrogen-substituted (N-substituted) carbon nanotubes (CNTs), using the Kubo formula combined with a self-consistent t-matrix approximation. N-substituted CNTs exhibit extremely high thermoelectric power factor (PF) values originating from a characteristic of one-dimensional materials where decrease in the carrier density increase both the electrical conductivity and the Seebeck coefficient in the low-N regime. The chemical potential dependence of the PF values of semiconducting CNTs has also been studied as a field-effect transistor and it turns out that the PF values show a noticeable maximum in the vicinity of the band edges. This result demonstrates that "band-edge engineering" will be crucial for solid development of high-performance thermoelectric materials.

  19. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  20. Pecuniary evaluation of provided service by local and global based dual-dimensional SDC and PSS2B in the context of deregulated power markets

    International Nuclear Information System (INIS)

    Shayeghi, H.; Hashemi, Y.

    2013-01-01

    Highlights: • Assessing the role and performance of SDC and PSS2B in deregulated power markets. • The profit allocation of WADC as an AS provider is involved in this work. • A dual-dimensional SDC scheme for UPFC is applied to damp the power system swings. • The high share of dual-dimensional SDC shows capability of it in enhancing security. - Abstract: The problem of profit allocation of Unified Power Flow Controller-Supplementary Damping Controller (UPFC-SDC) and accelerating power PSS model (PSS2B) is an important and update issue which has not been properly directed yet. The model of UPFC-SDC that has been used in this paper is a dual-dimensional controller that first dimension of control is resulted from local signals and the second dimension is covered by global signals as additional measuring data from appropriate remote network locations, where swings are well observable. Thus, in this paper the profit allocation of Wide Area Damping Controller (WADC) is also presented as an undefined problem in security subject of deregulated power system. Assuming control action by UPFC-SDC and WADC as an Ancillary Service (AS), the contribution of UPFC-SDC in stability enhancement is evaluated. It is important to appropriately choose a criterion to assess the performance of UPFC-SDC, so that a suitable allocation of profit can be achieved. The sum of deviations of damping ratios and real part of eigenvalues is selected as Oscillation Damping Criterion (ODC). Two scenarios for valuation of small signal stability as an AS provided by UPFC-SDC is considered. The first scenario without retuning of controllers and in the second scenario controllers is retuned due to response of the market situation. A multi-objective optimization approach based on ODC, generation costs and UPFC cost is considered and then Non-Dominated Sorting Genetic Algorithm-II (NSGA-II) is utilized for solving this problem. A two area four machine test power system is considered for investigation

  1. Modelling and short-term forecasting of daily peak power demand in Victoria using two-dimensional wavelet based SDP models

    International Nuclear Information System (INIS)

    Truong, Nguyen-Vu; Wang, Liuping; Wong, Peter K.C.

    2008-01-01

    Power demand forecasting is of vital importance to the management and planning of power system operations which include generation, transmission, distribution, as well as system's security analysis and economic pricing processes. This paper concerns the modeling and short-term forecast of daily peak power demand in the state of Victoria, Australia. In this study, a two-dimensional wavelet based state dependent parameter (SDP) modelling approach is used to produce a compact mathematical model for this complex nonlinear dynamic system. In this approach, a nonlinear system is expressed by a set of linear regressive input and output terms (state variables) multiplied by the respective state dependent parameters that carry the nonlinearities in the form of 2-D wavelet series expansions. This model is identified based on historical data, descriptively representing the relationship and interaction between various components which affect the peak power demand of a certain day. The identified model has been used to forecast daily peak power demand in the state of Victoria, Australia in the time period from the 9th of August 2007 to the 24th of August 2007. With a MAPE (mean absolute prediction error) of 1.9%, it has clearly implied the effectiveness of the identified model. (author)

  2. Power

    DEFF Research Database (Denmark)

    Elmholdt, Claus Westergård; Fogsgaard, Morten

    2016-01-01

    and creativity suggests that when managers give people the opportunity to gain power and explicate that there is reason to be more creative, people will show a boost in creative behaviour. Moreover, this process works best in unstable power hierarchies, which implies that power is treated as a negotiable....... It is thus a central point that power is not necessarily something that breaks down and represses. On the contrary, an explicit focus on the dynamics of power in relation to creativity can be productive for the organisation. Our main focus is to elaborate the implications of this for practice and theory...

  3. [Current role of color Doppler ultrasound in acute renal failure].

    Science.gov (United States)

    Bertolotto, M; Quaia, E; Rimondini, A; Lubin, E; Pozzi Mucelli, R

    2001-01-01

    Acute Renal Failure (ARF) is characterized by a rapid decline of the glomerular filtration rate, due to hypotension (prerenal ARF), obstruction of the urinary tract (post-renal ARF) or renal parenchymal disease (renal ARF). The differential diagnosis among different causes of ARF is based on anamnesis, clinical symptoms and laboratory data. Usually ultrasound (US) is the only imaging examination performed in these patients, because it is safe and readily available. In patients with ARF gray scale US is usually performed to rule out obstruction since it is highly sensitive to recognize hydronephrosis. Patients with renal ARF have no specific changes in renal morphology. The size of the kidneys is usually normal or increased, with smooth margins. Detection of small kidneys suggests underlying chronic renal pathology and worse prognosis. Echogenicity and parenchymal thickness are usually normal, but in some cases there are hyperechogenic kidneys, increased parenchymal thickness and increased cortico-medullary differentiation. Evaluation of renal vasculature with pulsed Doppler US is useful in the differential diagnosis between prerenal ARF and acute tubular necrosis (ATN), and in the diagnosis of renal obstruction. Latest generation US apparatus allow color Doppler and power Doppler evaluation of renal vasculature up to the interlobular vessels. A significant, but non specific, reduction in renal perfusion is usually appreciable in the patients with ARF. There are renal pathologic conditions presenting with ARF in which color Doppler US provides more specific morphologic and functional information. In particular, color Doppler US often provides direct or indirect signs which can lead to the right diagnosis in old patients with chronic renal insufficiency complicated with ARF, in patients with acute pyelonephritis, hepatic disease, vasculitis, thrombotic microangiopathies, and in patients with acute thrombosis of the renal artery and vein. Contrast enhanced US is

  4. Modelling of the thermal parameters of high-power linear laser-diode arrays. Two-dimensional transient model

    International Nuclear Information System (INIS)

    Bezotosnyi, V V; Kumykov, Kh Kh

    1998-01-01

    A two-dimensional transient thermal model of an injection laser is developed. This model makes it possible to analyse the temperature profiles in pulsed and cw stripe lasers with an arbitrary width of the stripe contact, and also in linear laser-diode arrays. This can be done for any durations and repetition rates of the pump pulses. The model can also be applied to two-dimensional laser-diode arrays operating quasicontinuously. An analysis is reported of the influence of various structural parameters of a diode array on the thermal regime of a single laser. The temperature distributions along the cavity axis are investigated for different variants of mounting a crystal on a heat sink. It is found that the temperature drop along the cavity length in cw and quasi-cw laser diodes may exceed 20%. (lasers)

  5. Characterisation of middle-distillates by comprehensive two-dimensional gas chromatography (GC x GC): A powerful alternative for performing various standard analysis of middle-distillates.

    Science.gov (United States)

    Vendeuvre, Colombe; Ruiz-Guerrero, Rosario; Bertoncini, Fabrice; Duval, Laurent; Thiébaut, Didier; Hennion, Marie-Claire

    2005-09-09

    The detailed characterisation of middle distillates is essential for a better understanding of reactions involved in refining process. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GC x GC) is a powerful tool for improving characterisation of petroleum samples. The aim of this paper is to compare GC x GC and various ASTM methods -- gas chromatography (GC), liquid chromatography (LC) and mass spectrometry (MS) -- for group type separation and detailed hydrocarbon analysis. Best features of GC x GC are demonstrated and compared to these techniques in terms of cost, time consumption and accuracy. In particular, a new approach of simulated distillation (SimDis-GC x GC) is proposed: compared to the standard method ASTM D2887 it gives unequal information for better understanding of conversion process.

  6. Doppler-guided retrograde catheterization system

    Science.gov (United States)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  7. Editorial special issue on "Laser Doppler vibrometry"

    Science.gov (United States)

    Vanlanduit, Steve; Dirckx, Joris

    2017-12-01

    The invention of the laser in 1960 has opened up many opportunities in the field of measurement science and technology. Just a few years after the invention of the laser, a novel fluid flow measurement technique based on the Doppler effect was introduced: at that moment the laser Doppler anemometer or shortly LDA [1] was born. The technique enabled fluid velocity measurement by using the light of a He-Ne beam which was scattered by very small polystyrene spheres entrained in the fluid. Later on, in the late nineteen seventees it was recognized that the detection of the Doppler frequency shift that occurs when light is scattered by a moving surface can also be used to measure the vibration velocity of an object. The instrument to perform these vibration measurements was called the laser Doppler vibrometer or LDV [2]. In the last decades several technological advances were made in the field of laser Doppler vibrometry. The result is that nowadays, velocity measurements of fluids (using LDA) and vibrating objects (using LDV) are performed in many challenging applications in different fields (microelectronics, civil structures, biomedical engineering, material science, etc.).

  8. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  9. Verification of MC{sup 2}-3 Doppler Sample Models in ZPPR-15 D Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Min Jae; Hartanto, Donny; Kim, Sang Ji [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In this paper, the change of reaction rate and broadened cross section were estimated by as-built MCNP models for metallic uranium sample in ZPPR-15D using ENDF/B-VII.0 library, and the results were compared with deterministic calculations provided in previous work. The Doppler broadening is an instant feedback mechanism that improves safety and stability for both thermal and fast reactors. Therefore, the accuracy of Doppler coefficient becomes an important parameter in reactor design as well as in the safety analysis. The capability of the Doppler worth calculation by a modern computer code suites such as MC2-3 and DIF3DVARIANT, has been validated against the Zero Power Physics Reactor-15 (ZPPR-15) Doppler worth measurement experiments. For the same experiments, our previous work suggested four different MC2-3 Doppler sample models for enhanced accuracy, which are combinations of heterogeneous models and the super cell approach. The MOC and MOC-SPC models showed the smallest error in estimating the U-238 total cross section of Doppler sample N-11, and the Doppler broadening effects are well applied to the cross section compared to other two models, HOM and SPC. The effects of the super cell approach can be hardly seen, since the broadened cross section is almost the same with and without the super cell approach. Comparing the transition of reaction density, MOC and MOC-SPC models also show similar behavior as MCNP's with minor errors. As a conclusion, we could obtain more consistent broadened cross section as well as reaction density transition by providing heterogeneous models from MC2-3's MOC module.

  10. Visualizing flow fields using acoustic Doppler current profilers and the Velocity Mapping Toolbox

    Science.gov (United States)

    Jackson, P. Ryan

    2013-01-01

    The purpose of this fact sheet is to provide examples of how the U.S. Geological Survey is using acoustic Doppler current profilers for much more than routine discharge measurements. These instruments are capable of mapping complex three-dimensional flow fields within rivers, lakes, and estuaries. Using the Velocity Mapping Toolbox to process the ADCP data allows detailed visualization of the data, providing valuable information for a range of studies and applications.

  11. Cryotherapy decreases synovial Doppler activity and pain in knee arthritis: A randomized-controlled trial.

    Science.gov (United States)

    Guillot, Xavier; Tordi, Nicolas; Prati, Clément; Verhoeven, Frank; Pazart, Lionel; Wendling, Daniel

    2017-07-01

    To measure and compare the effects of 2 local cryotherapy techniques on synovial power Doppler activity (primary outcome) and pain in non-septic knee arthritis without any concurrent treatment. 30 patients were randomized (ice: 30min, n=15 or cold CO 2 : 2min, n=15 both applied twice at 8h interval). Contralateral non-treated arthritic knees were used as paired controls (n=11 and n=10 respectively). The PDUS semi-quantitative score (0-3) and pain visual analogic scale were evaluated before/after each cold application, 2min, 2h, 24h after the first application. PDUS scores were checked in double-blind by 2 ultrasonographists. The inter-class effect size of local cryotherapy on the power Doppler score remained significant the day after treatment in local cryotherapy-treated compared to contralateral non-treated knees (Global difference: -1 [95% confidence interval: -1.23; -0.77]; ice: -0.73 [-1.06; -0.4]; CO 2 : -0.7 [-1.18; -0.22]). Both techniques significantly and to the same extent reduced the power Doppler score and pain visual analogic scale at all evaluation times and globally throughout the 24 hour-study period. No dropout nor adverse event was reported. In multivariate analysis, the Power Doppler score decrease was associated with pain decrease, while pain decrease was associated with the female sex and ice technique. Local ice and cold CO 2 applied twice equally reduced synovial Power Doppler activity and pain over 24h in knee arthritis. These effects remained significant the day after treatment. ClinicalTrials.gov identifier: NCT02573298. Copyright © 2016 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  12. The three-dimensional particle-in-cell simulation analysis of cavity of high power subterahertz pulsed gyrotron

    International Nuclear Information System (INIS)

    Ito, Koyu; Jiang, Weihua

    2013-01-01

    High power sub-terahertz pulsed gyrotrons for Collective Thomson Scattering (CTS) diagnostics of fusion plasmas are being developed. The typical target parameters are: output power of 100-200 kW, operation frequency of 300 GHz, and pulsed length > 10 us. In order to support experimental development, numerical simulations were carried out by using Particle-In-Cell (PIC) code MAGIC. The oscillation mode of the electromagnetic radiation was selected as TE_1_5_,_2, for which the beam parameters and cavity dimensions were determined accordingly. The simulation results have showed maximum power of 144 kW at oscillation frequency of 292.80 GHz, with oscillation efficiency of 22.15%. (author)

  13. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  14. Inline Ultrasonic Rheometry by Pulsed Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, David M.; Greenwood, Margaret S.; Bamberger, Judith A.; Pappas, Richard A.

    2006-12-22

    This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined by using a pulsed ultrasonic Doppler velocimeter. This approach is ideal for making non-invasive, real-time measurements for monitoring and control. Rheograms of a shear thinning, thixotropic gel will be presented. The operating parameters and limitations of the Doppler-based instrument will be discussed. The most significant limitation is velocity gradient broadening of the Doppler spectra near the walls of the pipe. This limitation can be significant for strongly shear thinning fluids (depending also on the ratio of beam to pipe diameter and the transducer's insertion angle).

  15. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  16. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  17. The Assessment of Left Ventricular Time-Varying Radius Using Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Fardin Mirbolouk

    2012-03-01

    Full Text Available Background: Left ventricular twist/torsion is believed to be a sensitive indicator of systolic and diastolic performance. To obtain circumferential rotation using tissue Doppler imaging, we need to estimate the time-varying radius of the left ventricle throughout the cardiac cycle to convert the tangential velocity into angular velocity. Objectives: The aim of this study was to investigate accuracy of measured LV radius using tissue Doppler imaging throughout the cardiac cycle compared to two-dimensional (2D imaging. Methods: A total of 35 subjects (47±12 years old underwent transthoracic echocardiographic standard examinations. Left ventricular radius during complete cardiac cycle measured using tissue Doppler and 2D-imaging at basal and apical short axis levels. For this reason, the 2D-images and velocity-time data derived and transferred to a personal computer for off-line analysis. 2D image frames analyzed via a program written in the MATLAB software. Velocity-time data from anteroseptal at basal level (or anterior wall at apical level and posterior walls transferred to a spreadsheet Excel program for the radius calculations. Linear correlation and Bland-Altman analysis were calculated to assess the relationships and agreements between the tissue Doppler and 2D-measured radii throughout the cardiac cycle. Results: There was significant correlation between tissue Doppler and 2D-measured radii and the Pearson correlation coefficients were 0.84 to 0.97 (P<0.05. Bland-Altman analysis by constructing the 95% limits of agreement showed that the good agreements existed between the two methods. Conclusion: It can be concluded from our experience that the tissue Doppler imaging can reasonably estimate radius of the left ventricle throughout the cardiac cycle.

  18. An Acoustic OFDM System with Symbol-by-Symbol Doppler Compensation for Underwater Communication

    Directory of Open Access Journals (Sweden)

    Tran MinhHai

    2016-01-01

    Full Text Available We propose an acoustic OFDM system for underwater communication, specifically for vertical link communications such as between a robot in the sea bottom and a mother ship in the surface. The main contributions are (1 estimation of time varying Doppler shift using continual pilots in conjunction with monitoring the drift of Power Delay Profile and (2 symbol-by-symbol Doppler compensation in frequency domain by an ICI matrix representing nonuniform Doppler. In addition, we compare our proposal against a resampling method. Simulation and experimental results confirm that our system outperforms the resampling method when the velocity changes roughly over OFDM symbols. Overall, experimental results taken in Shizuoka, Japan, show our system using 16QAM, and 64QAM achieved a data throughput of 7.5 Kbit/sec with a transmitter moving at maximum 2 m/s, in a complicated trajectory, over 30 m vertically.

  19. An Acoustic OFDM System with Symbol-by-Symbol Doppler Compensation for Underwater Communication

    Science.gov (United States)

    MinhHai, Tran; Rie, Saotome; Suzuki, Taisaku; Wada, Tomohisa

    2016-01-01

    We propose an acoustic OFDM system for underwater communication, specifically for vertical link communications such as between a robot in the sea bottom and a mother ship in the surface. The main contributions are (1) estimation of time varying Doppler shift using continual pilots in conjunction with monitoring the drift of Power Delay Profile and (2) symbol-by-symbol Doppler compensation in frequency domain by an ICI matrix representing nonuniform Doppler. In addition, we compare our proposal against a resampling method. Simulation and experimental results confirm that our system outperforms the resampling method when the velocity changes roughly over OFDM symbols. Overall, experimental results taken in Shizuoka, Japan, show our system using 16QAM, and 64QAM achieved a data throughput of 7.5 Kbit/sec with a transmitter moving at maximum 2 m/s, in a complicated trajectory, over 30 m vertically. PMID:27057558

  20. An Acoustic OFDM System with Symbol-by-Symbol Doppler Compensation for Underwater Communication.

    Science.gov (United States)

    MinhHai, Tran; Rie, Saotome; Suzuki, Taisaku; Wada, Tomohisa

    2016-01-01

    We propose an acoustic OFDM system for underwater communication, specifically for vertical link communications such as between a robot in the sea bottom and a mother ship in the surface. The main contributions are (1) estimation of time varying Doppler shift using continual pilots in conjunction with monitoring the drift of Power Delay Profile and (2) symbol-by-symbol Doppler compensation in frequency domain by an ICI matrix representing nonuniform Doppler. In addition, we compare our proposal against a resampling method. Simulation and experimental results confirm that our system outperforms the resampling method when the velocity changes roughly over OFDM symbols. Overall, experimental results taken in Shizuoka, Japan, show our system using 16QAM, and 64QAM achieved a data throughput of 7.5 Kbit/sec with a transmitter moving at maximum 2 m/s, in a complicated trajectory, over 30 m vertically.

  1. Creation of problem-dependent Doppler-broadened cross sections in the KENO Monte Carlo code

    International Nuclear Information System (INIS)

    Hart, Shane W.D.; Celik, Cihangir; Maldonado, G. Ivan; Leal, Luiz

    2016-01-01

    Highlights: • A quick method of Doppler broadening one- and two-dimensional cross sections has been added to KENO. • The method uses a finite difference method to broaden data to user defined temperatures. • Various problems and benchmarks were run to showcase results. • Results with the Doppler broadened cross sections are closer to benchmark results. - Abstract: This paper introduces a quick method for improving the accuracy of Monte Carlo simulations by generating one- and two-dimensional cross sections at a user-defined temperature before performing transport calculations. A finite difference method is used to Doppler-broaden cross sections to the desired temperature, and unit-base interpolation is done to generate the probability distributions for double differential two-dimensional thermal moderator cross sections at any arbitrarily user-defined temperature. The accuracy of these methods is tested using a variety of contrived problems. In addition, various benchmarks at elevated temperatures are modeled, and results are compared with benchmark results. The problem-dependent cross sections are observed to produce eigenvalue estimates that are closer to the benchmark results than those without the problem-dependent cross sections.

  2. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  3. An assessment of methods of calculating Doppler effects in plutonium fuelled sodium cooled fast reactors

    International Nuclear Information System (INIS)

    Butland, A.T.D.; Reddell, G.

    1979-01-01

    After a survey of the requirements, an assessment of UK methods and data is made on the basis of the following work. First, the analysis of the SEFOR Doppler experiments, carried out using the UK FGL5 fine group nuclear data library, the MURAL cell code and whole reactor diffusion theory calculations of the neutron flux. Second, the analysis of some Japanese FCA central sample perturbation measurements of structural material Doppler effects. Third, an assessment of the accuracy of Doppler predictions in a sodium voided core using results from Zebra 5 and BIZET, and theoretical studies of additional effects relevant to power reactors and not covered by the above analyses, including the following, the calculation of Doppler effects at high temperature, fuel cycle and burn-up effects, and the heterogeneity effects of large fuelled subassemblies in pin geometry. The importance of crystalline binding effects in the fuel are discussed as is the importance of reactor material boundaries in the calculation of resonance shielding effects. Some suggestions for further Doppler studies are made. (U.K.)

  4. Proposed protocols for peripheral and renal Doppler

    International Nuclear Information System (INIS)

    Fonseca Portuguez, Adriana

    2009-01-01

    A literature review was performed in order to prepare a summary of the important concepts of Doppler and applications in peripheral vascular evaluation and renal. The normal characteristics are summarized and explained in each vascular system and diagnostic criteria of the disorders frequently encountered in practice. Requested more studies have been identified and proposed protocols and report sheets have been developed to standardize the methodology of realization of several Doppler studies. The variability between operators has been treated to reduce as much as possible and follow-up studies have provided in patients who need. (author) [es

  5. Local irradiation effects of one-dimensional ZnO based self-powered asymmetric Schottky barrier UV photodetector

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Yaxue [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Qi, Junjie, E-mail: junjieqi@ustb.edu.cn [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Biswas, Chandan [Department of Electrical Engineering, University of California Los Angeles, California 90095 (United States); Li, Feng; Zhang, Kui; Li, Xin [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Zhang, Yue, E-mail: yuezhang@ustb.edu.cn [School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Key Laboratory of New Energy Materials and Technologies, University of Science and Technology Beijing, Beijing 100083 (China)

    2015-09-15

    A self-powered metal-semiconductor-metal (MSM) UV photodetector was successfully fabricated based on Ag/ZnO/Au structure with asymmetric Schottky barriers. This exhibits excellent performance compared to many previous studies. Very high photo-to-dark current ratio (approximately 10{sup 5}–10{sup 6}) was demonstrated without applying any external bias, and very fast switching time of less than 30 ms was observed during the investigation. Opposite photocurrent direction was generated by irradiating different Schottky diodes in the fabricated photodetector. Furthermore, the device performance was optimized by largely irradiating both the ZnO microwire (MW) junctions. Schottky barrier effect theory and O{sub 2} adsorption–desorption theories were used to investigate the phenomenon. The device has potential applications in self-powered UV detection field and can be used as electrical power source for electronic, optoelectronic and mechanical devices. - Highlights: • A self-powered Schottky barrier UV photodetector based on 1-D ZnO is fabricated. • For the first time we investigate the local irradiation effects of UV detector. • Irradiating both the junctions and ZnO can optimize the performance of the device.

  6. The predictive power of the business and bank sentiment of firms : A high-dimensional Granger causality approach

    NARCIS (Netherlands)

    Wilms, I.; Gelper, S.E.C.; Croux, C.

    2016-01-01

    We study the predictive power of industry-specific economic sentiment indicators for future macro-economic developments. In addition to the sentiment of firms towards their own business situation, we study their sentiment with respect to the banking sector – their main credit providers. The use of

  7. Color doppler energy (CDE) : initial ten-months experience

    International Nuclear Information System (INIS)

    Ro, Young Jin; Son, Hyun Ju; Lee, Suck Hong; Kim, Byung Soo; Han, Kook Sang; Nam, SAng Hwa; Lee, Keum Seob; Shin Se Kwon

    1996-01-01

    Color Doppler imaging(CDI) has shortcomings, including random noise, aliasing, and angle dependence. To overcome these, a method using CD US, termed power doppler or Color Doppler Energy(CDE), has recently been introduced. The purpose of this study was to show the clinical usefulness of CDE. We retrospectively analyzed the CDI and CDE of 61 cases(20 renal pseudotumors, 8 musculoskeletal inflammations, 17 epididymitis or epididymo-orchitis, 3 varicoceles, 1 normal testis, 1 hepatocellualr carcinoma, 7 renal cell carcinoma, 1 renal angiomyolipoma, and 3 splenic varices). CDI and CDE scans were obtained at the same region with constant scan plane. The color gain was increased until noise first became perceptible, and scans were always obtained in such a way that the maximum amount of vascularity was shown. Thereafter, the vascularity, vascular displacement, and the vascular relationship between CDI and CDE were compared. In 17 of 20 cases of pseudotumor in the kidney, normal vascularity was identified in CDI and CDE, but was more cleary visible in CDE. In three cases, there was no visible vascularity in CDI, but normal vascularity in CDE. In eight cases of musculoskeletal inflammation and 17 cases of epididymitis with or without orchitis, the vascularity was increased due to hyperemia, which was more prominently seen in CDE than in CDI. In three varicoceles, CDE appeared to be better in demonstrating low velocity flow. In one patient who was suspected of having acute testicular torsion, CDE was helpful in excluding this suspicion. In one case of hepatocellualr carcinoma, seven cases of renal cell carcinoma, one case of renal angiomyolipoma, and three cases of splenic varices, CDE was better than CDI in showing the vascularity, vascular relationship, and vascular displacement

  8. Homogenization of Doppler broadening in spin-noise spectroscopy

    Science.gov (United States)

    Petrov, M. Yu.; Ryzhov, I. I.; Smirnov, D. S.; Belyaev, L. Yu.; Potekhin, R. A.; Glazov, M. M.; Kulyasov, V. N.; Kozlov, G. G.; Aleksandrov, E. B.; Zapasskii, V. S.

    2018-03-01

    The spin-noise spectroscopy, being a nonperturbative linear optics tool, is still reputed to reveal a number of capabilities specific to nonlinear optics techniques. The effect of the Doppler broadening homogenization discovered in this work essentially widens these unique properties of spin-noise spectroscopy. We investigate spin noise of a classical system—cesium atoms vapor with admixture of buffer gas—by measuring the spin-induced Faraday rotation fluctuations in the region of D 2 line. The line, under our experimental conditions, is strongly inhomogeneously broadened due to the Doppler effect. Despite that, optical spectrum of the spin-noise power has the shape typical for the homogeneously broadened line with a dip at the line center. This fact is in stark contrast with the results of previous studies of inhomogeneous quantum dot ensembles and Doppler broadened atomic systems. In addition, the two-color spin-noise measurements have shown, in a highly spectacular way, that fluctuations of the Faraday rotation within the line are either correlated or anticorrelated depending on whether the two wavelengths lie on the same side or on different sides of the resonance. The experimental data are interpreted in the frame of the developed theoretical model which takes into account both kinetics and spin dynamics of Cs atoms. It is shown that the unexpected behavior of the Faraday rotation noise spectra and effective homogenization of the optical transition in the spin-noise measurements are related to smallness of the momentum relaxation time of the atoms as compared with their spin-relaxation time. Our findings demonstrate abilities of spin-noise spectroscopy for studying dynamic properties of inhomogeneously broadened ensembles of randomly moving spins.

  9. The role of colour flow Doppler in the investigation of the salivary gland tumour

    International Nuclear Information System (INIS)

    Bradley, M.J.; Durham, L.H.; Lancer, J.M.

    2000-01-01

    AIMS: Ultrasound is a highly effective imaging technique to determine salivary gland tumours and may help to identify many benign lesions. The aim of this study is to evaluate whether colour Doppler is able to further differentiate the malignant tumour. METHODS: Fifty-six patients with salivary gland lesions were prospectively assessed using ultrasound imaging with colour flow and power Doppler. The peak systolic velocity (PSV) was measured and the pulsatility index (PI) and resistive index (RI) calculations were performed on the pulsed wave traces. The real time ultrasound morphology and the Doppler information were correlated with the histology. RESULTS: In 18 of the 56 patients, no internal colour flow or power Doppler changes could be detected. The real time ultrasound morphology diagnosed benign disease with sensitivity of 89.7% with specificity of 57.1%. The positive predictive value was 93.6%. There were no significant differences in the colour Doppler appearances in terms of vessel type or intratumour distribution which could separate benign from malignant conditions. However, there was statistical discrimination for PI and RI values (P = 0.0006, P = 0.0002, respectively). No malignant lesions were seen when the PI was less than 1.8 and RI was less than 0.8. The PSV was elevated in several cases (> 50 cm per s) but there was no statistical correlation with malignancy. CONCLUSION: The risk of malignancy increases by a third when the colour Doppler demonstrates increased intratumour vascular resistance (RI > 0.8 and PI > 1.8), with positive predictive value of 97.3% (sensitivity 75.5%, specificity 85.7%). Bradley, M.J. (2000). Clinical Radiology 55, 759-762

  10. Distribution of Doppler Redshifts of Associated Absorbers of SDSS ...

    Indian Academy of Sciences (India)

    The authors searched all ... quasar, where the contribution of the Doppler motion is relatively small. ..... might contribute to the Doppler redshift distribution. 5. ... out accounting for the contamination of intervening absorption systems, which can.

  11. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  12. Operational Bright-Band Snow Level Detection Using Doppler Radar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A method to detect the bright-band snow level from radar reflectivity and Doppler vertical velocity data collection with an atmospheric profiling Doppler radar. The...

  13. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The EDOP provides vertically profiled reflectivity and Doppler velocity at aircraft nadir along the flight track. The ER-2 Doppler radar (EDOP) is an X-band (9.6...

  14. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  15. Synthesis of Three-Dimensional Nanoporous Li-Rich Layered Cathode Oxides for High Volumetric and Power Energy Density Lithium-Ion Batteries.

    Science.gov (United States)

    Qiu, Bao; Yin, Chong; Xia, Yonggao; Liu, Zhaoping

    2017-02-01

    As rechargeable Li-ion batteries have expanded their applications into on-board energy storage for electric vehicles, the energy and power must be increased to meet the new demands. Li-rich layered oxides are one of the most promising candidate materials; however, it is very difficult to make them compatible with high volumetric energy density and power density. Here, we develop an innovative approach to synthesize three-dimensional (3D) nanoporous Li-rich layered oxides Li[Li 0.144 Ni 0.136 Co 0.136 Mn 0.544 ]O 2 , directly occurring at deep chemical delithiation with carbon dioxide. It is found that the as-prepared material presents a micrometer-sized spherical structure that is typically composed of interconnected nanosized subunits with narrow distributed pores at 3.6 nm. As a result, this unique 3D micro-/nanostructure not only has a high tap density over 2.20 g cm -3 but also exhibits excellent rate capability (197.6 mA h g -1 at 1250 mA g -1 ) as an electrode. The excellent electrochemical performance is ascribed to the unique nanoporous micro-nanostructures, which facilitates the Li + diffusion and enhances the structural stability of the Li-rich layered cathode materials. Our work offers a comprehensive designing strategy to construct 3D nanoporous Li-rich layered oxides for both high volumetric energy density and power density in Li-ion batteries.

  16. Greybody factors for a minimally coupled scalar field in a three-dimensional Einstein-power-Maxwell black hole background

    Science.gov (United States)

    Panotopoulos, Grigoris; Rincón, Ángel

    2018-04-01

    In the present work we study the propagation of a probe minimally coupled scalar field in Einstein-power-Maxwell charged black hole background in (1 +2 ) dimensions. We find analytical expressions for the reflection coefficient as well as for the absorption cross section in the low energy regime, and we show graphically their behavior as functions of the frequency for several values of the free parameters of the theory.

  17. Transcranial Doppler velocimetry in aneurysmal subarachnoid haemorrhage

    DEFF Research Database (Denmark)

    Staalsø, J M; Edsen, T; Romner, B

    2013-01-01

    -coded transcranial Doppler (TCCD), with the secondary aim of describing prediction of angiographic vasospasm and mortality. METHODS: /st>Sixty patients and 70 healthy controls were each examined in duplicate by alternating operators. A total of 939 measurements divided on 201 examination sets were conducted by four...

  18. Doppler Sonographic Evaluation of Venogenic Extremity Swellings ...

    African Journals Online (AJOL)

    2017-09-14

    Sep 14, 2017 ... potentially lead to many complications including life-threatening pulmonary arterial thrombosis. Screening and confirmation ... and exclusion of acute lower extremity DVT. Duplex ultrasound is considered as the ... this study evaluates the role of Doppler sonography in the clinical management of suspected.

  19. Complex regression Doppler optical coherence tomography

    Science.gov (United States)

    Elahi, Sahar; Gu, Shi; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.

    2018-04-01

    We introduce a new method to measure Doppler shifts more accurately and extend the dynamic range of Doppler optical coherence tomography (OCT). The two-point estimate of the conventional Doppler method is replaced with a regression that is applied to high-density B-scans in polar coordinates. We built a high-speed OCT system using a 1.68-MHz Fourier domain mode locked laser to acquire high-density B-scans (16,000 A-lines) at high enough frame rates (˜100 fps) to accurately capture the dynamics of the beating embryonic heart. Flow phantom experiments confirm that the complex regression lowers the minimum detectable velocity from 12.25 mm / s to 374 μm / s, whereas the maximum velocity of 400 mm / s is measured without phase wrapping. Complex regression Doppler OCT also demonstrates higher accuracy and precision compared with the conventional method, particularly when signal-to-noise ratio is low. The extended dynamic range allows monitoring of blood flow over several stages of development in embryos without adjusting the imaging parameters. In addition, applying complex averaging recovers hidden features in structural images.

  20. Doppler Shift Compensation Schemes in VANETs

    Directory of Open Access Journals (Sweden)

    F. Nyongesa

    2015-01-01

    Full Text Available Over the last decade vehicle-to-vehicle (V2V communication has received a lot of attention as it is a crucial issue in intravehicle communication as well as in Intelligent Transportation System (ITS. In ITS the focus is placed on integration of communication between mobile and fixed infrastructure to execute road safety as well as nonsafety information dissemination. The safety application such as emergence alerts lays emphasis on low-latency packet delivery rate (PDR, whereas multimedia and infotainment call for high data rates at low bit error rate (BER. The nonsafety information includes multimedia streaming for traffic information and infotainment applications such as playing audio content, utilizing navigation for driving, and accessing Internet. A lot of vehicular ad hoc network (VANET research has focused on specific areas including channel multiplexing, antenna diversity, and Doppler shift compensation schemes in an attempt to optimize BER performance. Despite this effort few surveys have been conducted to highlight the state-of-the-art collection on Doppler shift compensation schemes. Driven by this cause we survey some of the recent research activities in Doppler shift compensation schemes and highlight challenges and solutions as a stock-taking exercise. Moreover, we present open issues to be further investigated in order to address the challenges of Doppler shift in VANETs.

  1. Fifty Years of HF Doppler Observations

    Directory of Open Access Journals (Sweden)

    T Ogawa

    2009-04-01

    Full Text Available High frequency Doppler observations of the ionosphere began in August of 1957 in Kyoto. The number of the observation points worldwide were about 40 in 1980 and are about 20 at present. By this method the movement of the ionosphere reflection height and electron density below the height can be observed. Such variations are occurred by a wide variety of sources.

  2. Ultrasonic Doppler color in glaucoma: Concordance study

    International Nuclear Information System (INIS)

    Uriza, Felipe; Useche, Nicolas

    2005-01-01

    Our study demonstrates that US color Doppler is a non invasive, reliable and reproducible method for the evaluation of the orbitary flow in normal and glaucomatous patients. However is suggested that every group evaluates the inter and intraobserver variability because of the lack of universal reference velocity measurements

  3. Aerosol distribution measurements by laser - Doppler - spectroscopy

    International Nuclear Information System (INIS)

    Baldassari, J.

    1977-01-01

    Laser-Doppler-Spectroscopy is used to study particle size distribution, especially sodium aerosols, in the presence of uncondensable gases. Theoretical basis are given, and an experimental technique is described. First theoretical results show reasonably good agreement with experimental data available; this method seems to be a promising one. (author)

  4. Laser Doppler thermometry in flat flames

    NARCIS (Netherlands)

    Maaren, van A.; Goey, de L.P.H.

    1994-01-01

    Laser Doppler Velocimetry measurements are performed in flat flames, stabilized on a newly developed flat-flame burner. It is shown that the velocity component perpendicular to the main flow direction, induced by expansion in the reaction zone and buoyancy in the burnt gas, is significant. A method

  5. Six-dimensional modeling of coherent bunch instabilities and related freedback systems in storage rings with power-series maps for the lattice

    International Nuclear Information System (INIS)

    Bengtsson, J.; Briggs, D.; Meddahi, M.

    1994-06-01

    The authors have developed 6-dimensional phase-space code that tracks macroparticles for the study of coherent bunch instabilities and related feedback systems. The model is based on power-series maps to represent the lattice, and allows for straightforward inclusion of effects such as amplitude dependent tune shift, chromaticity, synchrotron oscillations, and synchrotron radiation. It simulates long range wake fields such as resistive-wall effects as well as the higher order modes in cavities. The model has served to study the dynamics relevant to the transverse feedback system currently being commissioned for the Advanced Light Source (ALS). Current work integrates earlier versions into a modular system that includes models for transverse and longitudinal feedback systems. It is designed to provide a modular approach to the dynamics and diagnostics, allowing a user to modify the model of a storage ring at run-time without recompilation

  6. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The TCSP ER-2 DOPPLER RADAR (EDOP) dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of the ER-2...

  7. CAMEX-4 ER-2 DOPPLER RADAR V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 ER-2 Doppler Radar dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of ER-2. The...

  8. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  9. Three-dimensional Printing and 3D Slicer: Powerful Tools in Understanding and Treating Structural Lung Disease.

    Science.gov (United States)

    Cheng, George Z; San Jose Estepar, Raul; Folch, Erik; Onieva, Jorge; Gangadharan, Sidhu; Majid, Adnan

    2016-05-01

    Recent advances in the three-dimensional (3D) printing industry have enabled clinicians to explore the use of 3D printing in preprocedural planning, biomedical tissue modeling, and direct implantable device manufacturing. Despite the increased adoption of rapid prototyping and additive manufacturing techniques in the health-care field, many physicians lack the technical skill set to use this exciting and useful technology. Additionally, the growth in the 3D printing sector brings an ever-increasing number of 3D printers and printable materials. Therefore, it is important for clinicians to keep abreast of this rapidly developing field in order to benefit. In this Ahead of the Curve, we review the history of 3D printing from its inception to the most recent biomedical applications. Additionally, we will address some of the major barriers to wider adoption of the technology in the medical field. Finally, we will provide an initial guide to 3D modeling and printing by demonstrating how to design a personalized airway prosthesis via 3D Slicer. We hope this information will reduce the barriers to use and increase clinician participation in the 3D printing health-care sector. Copyright © 2016 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  10. Doppler speedometer for micro-organisms

    International Nuclear Information System (INIS)

    Penkov, F.; Tuleushev, A.; Lisitsyn, V.; Kim, S.; Tuleushev, Yu.

    1996-01-01

    Objective of Investigations: Development and creation of the Doppler speedometer for micro-organisms which allows to evaluate, in a real temporal scale, variations in the state of water suspension of micro-organisms under the effect of chemical, physical and other external actions. Statement of the Problem The main problem is absence of reliable, accessible for users and simple, in view of application, Doppler speedometers for micro-organisms. Nevertheless, correlation Doppler spectrometry in the regime of heterodyning the supporting and cell-scattered laser radiation is welt known. The main idea is that the correlation function of photo-current pulses bears an information on the averages over the assembly of cell velocities. For solving the biological problems, construction of auto-correlation function in the real-time regime with the delay time values comprising, function in the real-time regime with the delay time values comprising, nearly, 100 me (10 khz) or higher is needed. Computers of high class manage this problem using but the program software. Due to this, one can simplify applications of the proposed techniques provided he creates the Doppler speedometer for micro-organism on a base of the P entium . Expected Result Manufactured operable mock-up of the Doppler speedometer for micro-organisms in a form of the auxiliary computer block which allows to receive an information, in the real time scale, on the results of external effects of various nature on the cell assembly in transparent medium with a small volume of the studied cell suspension

  11. Calculations of the three-dimensional power distribution in the Fort St. Vrain reactor using UK methods and data

    Energy Technology Data Exchange (ETDEWEB)

    Anderson, D W

    1973-04-15

    Assessments of the ability of UK methods and data developed primarily for the low enriched uranium cycle to simulate thorium cycle HTRs haye been extended to cover reactivity and power distributions in commercial size reactors. The Fort St. Vrain 330 MW(E) HTR being built in the United States by Gulf General Atomic has been chosen as a convenient object for such a study since detailed design information together with the results of GGA's own calculations have been published. The results obtained are in good agreement with those obtained by GGA and indicate that both thorium and low enriched cycle HTRs can be adequately modelled with UK data and methods.

  12. A one-dimensional, one-group absorption-production nodal method for neutron flux and power distributions calculations

    International Nuclear Information System (INIS)

    Ferreira, C.R.

    1984-01-01

    It is presented the absorption-production nodal method for steady and dynamical calculations in one-dimension and one group energy. It was elaborated the NOD1D computer code (in FORTRAN-IV language). Calculations of neutron flux and power distributions, burnup, effective multiplication factors and critical boron concentration were made with the NOD1D code and compared with results obtained through the CITATION code, which uses the finite difference method. The nuclear constants were produced by the LEOPARD code. (M.C.K.) [pt

  13. Wind turbine wake visualization and characteristics analysis by Doppler lidar.

    Science.gov (United States)

    Wu, Songhua; Liu, Bingyi; Liu, Jintao; Zhai, Xiaochun; Feng, Changzhong; Wang, Guining; Zhang, Hongwei; Yin, Jiaping; Wang, Xitao; Li, Rongzhong; Gallacher, Daniel

    2016-05-16

    Wind power generation is growing fast as one of the most promising renewable energy sources that can serve as an alternative to fossil fuel-generated electricity. When the wind turbine generator (WTG) extracts power from the wind, the wake evolves and leads to a considerable reduction in the efficiency of the actual power generation. Furthermore, the wake effect can lead to the increase of turbulence induced fatigue loads that reduce the life time of WTGs. In this work, a pulsed coherent Doppler lidar (PCDL) has been developed and deployed to visualize wind turbine wakes and to characterize the geometry and dynamics of wakes. As compared with the commercial off-the-shelf coherent lidars, the PCDL in this work has higher updating rate of 4 Hz and variable physical spatial resolution from 15 to 60 m, which improves its capability to observation the instantaneous turbulent wind field. The wind speed estimation method from the arc scan technique was evaluated in comparison with wind mast measurements. Field experiments were performed to study the turbulent wind field in the vicinity of operating WTGs in the onshore and offshore wind parks from 2013 to 2015. Techniques based on a single and a dual Doppler lidar were employed for elucidating main features of turbine wakes, including wind velocity deficit, wake dimension, velocity profile, 2D wind vector with resolution of 10 m, turbulence dissipation rate and turbulence intensity under different conditions of surface roughness. The paper shows that the PCDL is a practical tool for wind energy research and will provide a significant basis for wind farm site selection, design and optimization.

  14. Comparative study of the performance of semiconductor laser based coherent Doppler lidars

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2012-01-01

    Coherent Doppler Lidars (CDLs), operating at an eye-safe 1.5-micron wavelength, have found promising applications in the optimization of wind-power production. To meet the wind-energy sector's impending demand for more cost-efficient industrial sensors, we have focused on the development of conti......Coherent Doppler Lidars (CDLs), operating at an eye-safe 1.5-micron wavelength, have found promising applications in the optimization of wind-power production. To meet the wind-energy sector's impending demand for more cost-efficient industrial sensors, we have focused on the development...... of continuous-wave CDL systems using compact, inexpensive semiconductor laser (SL) sources. In this work, we compare the performance of two candidate emitters for an allsemiconductor CDL system: (1) a monolithic master-oscillator-power-amplifier (MOPA) SL and (2) an external-cavity tapered diode laser (ECTDL)....

  15. Spatially Resolved MR-Compatible Doppler Ultrasound: Proof of Concept for Triggering of Diagnostic Quality Cardiovascular MRI for Function and Flow Quantification at 3T.

    Science.gov (United States)

    Crowe, Lindsey Alexandra; Manasseh, Gibran; Chmielewski, Aneta; Hachulla, Anne-Lise; Speicher, Daniel; Greiser, Andreas; Muller, Hajo; de Perrot, Thomas; Vallee, Jean-Paul; Salomir, Rares

    2018-02-01

    We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging. A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional electrocardiogram (ECG) and the proposed spatially resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic "false-triggered" image was retrospectively processed using metric optimized gating (MOG). Images were scored by expert readers, and sharpness, cardiac function and aortic flow were quantified. Four-dimensional (4-D) flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p ). ECG-, Doppler-triggered, and MOG ejection fractions were equivalent (p ), with false-triggered values significantly lower (p 0.05). 4-D flow quantification gave consistent results between ECG and Doppler triggering. We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible, i.e., fetal imaging.

  16. The medical Doppler in hand surgery: its scientific basis, applications, and the history of its namesake, Christian Johann Doppler.

    Science.gov (United States)

    Ghori, Ahmer K; Chung, Kevin C

    2007-12-01

    The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.

  17. Simulation of ion behavior in an open three-dimensional Paul trap using a power series method

    Energy Technology Data Exchange (ETDEWEB)

    Herbane, Mustapha Said, E-mail: mherbane@hotmail.com [King Khalid University, Faculty of Science, Department of Physics, P.O. Box 9004, Abha (Saudi Arabia); Berriche, Hamid [King Khalid University, Faculty of Science, Department of Physics, P.O. Box 9004, Abha (Saudi Arabia); Laboratoire des Interfaces et Matériaux Avancés, Physics Department, College of Science, University of Monastir, 5019 Monastir (Tunisia); Abd El-hady, Alaa [King Khalid University, Faculty of Science, Department of Physics, P.O. Box 9004, Abha (Saudi Arabia); Department of Physics, Faculty of Science, Zagazig University, Zagazig 44519 (Egypt); Al Shahrani, Ghadah [King Khalid University, Faculty of Science, Department of Physics, P.O. Box 9004, Abha (Saudi Arabia); Ban, Gilles; Fléchard, Xavier; Liénard, Etienne [LPC CAEN-ENSICAEN, 6 Boulevard du Marechal Juin, 14050 Caen Cedex (France)

    2014-07-01

    Simulations of the dynamics of ions trapped in a Paul trap with terms in the potential up to the order 10 have been carried out. The power series method is used to solve numerically the equations of motion of the ions. The stability diagram has been studied and the buffer gas cooling has been implemented by a Monte Carlo method. The dipole excitation was also included. The method has been applied to an existing trap and it has shown good agreement with the experimental results and previous simulations using other methods. - Highlights: • Paul trap with potentials up to the order 10. • Series solution of the ions equations of motion. • Hard sphere model for the simulation of the buffer gas cooling and simulation of the dipolar excitation.

  18. Two dimensional self-assembly zinc porphyrin and zinc phthalocyanine heterojunctions with record high power conversion efficiencies

    Science.gov (United States)

    Yu, Junting; Jiang, Zhou; Hao, Yifan; Zhu, Qianhong; Zhao, Mingliang; Jiang, Xue; Zhao, Jijun

    2018-06-01

    Compared to inorganic solar cells, the power conversion efficiencies (PCEs) of organic solar cells are much lower, but they are compensated by many merits such as lower cost, less weight, and tunable structures, making them prospective for further applications. Porphyrin and phthalocyanine are the two most significant materials for organic solar cells due to their strong light-absorbing properties and semiconductor characteristics. However, there is little research on the 2D heterojunction solar cells based on these two materials, meanwhile the PCEs of them are still low. Here we have self-assembled several 2D zinc porphyrins (ZnPors) and performed first-principles simulation to demonstrate their good stability, suitable light harvesting, and high charge carrier mobility. By perfectly matching lattice constants and molecular energy levels between those 2D ZnPors and our previous proposed zinc phthalocyanines (ZnPcs), 11 type-II organic heterojunctions are constructed to further improve their charge separation capability. Those advantages endow 2D ZnPors and ZnPcs appreciable PCEs for solar cells. Among them, the theoretical PCE of 2D ZnPors/ZnPcs heterojunctions achieves as high as 19.84%, which exceeds all reported organic solar cells, and even approaches the PCEs of inorganic solar cells. These results indicate that our 2D ZnPors and 2D ZnPcs are good candidate materials for future organic solar cells.

  19. Dynamical nature of inviscid power law for two dimensional turbulences and self-consistent spectrum and transport of plasma filaments

    International Nuclear Information System (INIS)

    Zhnag, Y.Z.; Mahajan, S.M.

    1994-01-01

    On basis of equal-time correlation theory (a non-perturbative approach) inviscid power laws of 2D isotropic plasma turbulences with one Lagrangian inviscid constant of motion are unambiguously solved by determining the dynamical characteristics. Two distinct types of induced transport according to the divergence of the inverse correlation length in the inviscid limit are revealed. This analysis also suggests a physically reasonable closure. The self-consistent system (a set of integral equations) for plasma filaments is investigated in detail, and is found to be a nonlinear differential eigenvalue problem for diffusion coefficient D, whereon the Dyson-like (integral) equation plays a role of boundary condition. This new type of transport is non-Bohm-like, and is very much like the quasilinear formula even in the strong turbulence regime. Physically, it arises from synchronization of shrinking squared correlation length with decorrelation time, for which the ''mixing-length'' breaks down. The shrinkage of correlation length is a characteristic pertaining to the new type of turbulence; its relationship with the turbulence observed in supershot regime on TFTR is commented on. (author). 12 refs, 2 figs

  20. Ultra-Low-Power Smart Electronic Nose System Based on Three-Dimensional Tin Oxide Nanotube Arrays.

    Science.gov (United States)

    Chen, Jiaqi; Chen, Zhuo; Boussaid, Farid; Zhang, Daquan; Pan, Xiaofang; Zhao, Huijuan; Bermak, Amine; Tsui, Chi-Ying; Wang, Xinran; Fan, Zhiyong

    2018-06-04

    In this work, we present a high-performance smart electronic nose (E-nose) system consisting of a multiplexed tin oxide (SnO 2 ) nanotube sensor array, read-out circuit, wireless data transmission unit, mobile phone receiver, and data processing application (App). Using the designed nanotube sensor device structure in conjunction with multiple electrode materials, high-sensitivity gas detection and discrimination have been achieved at room temperature, enabling a 1000 times reduction of the sensor's power consumption as compared to a conventional device using thin film SnO 2 . The experimental results demonstrate that the developed E-nose can identify indoor target gases using a simple vector-matching gas recognition algorithm. In addition, the fabricated E-nose has achieved state-of-the-art sensitivity for H 2 and benzene detection at room temperature with metal oxide sensors. Such a smart E-nose system can address the imperative needs for distributed environmental monitoring in smart homes, smart buildings, and smart cities.

  1. Transcranial Doppler sonography in familial hemiplegic migraine

    International Nuclear Information System (INIS)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A.

    1991-01-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab

  2. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  3. Transcranial Doppler sonography in familial hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A. (Universita la Sapienza, Roma (Italy))

    1991-02-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab.

  4. Renal duplex Doppler ultrasound findings in diabetics

    International Nuclear Information System (INIS)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon

    1993-01-01

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  5. Renal duplex Doppler ultrasound findings in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1993-12-15

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  6. An adaptive angle-doppler compensation method for airborne bistatic radar based on PAST

    Science.gov (United States)

    Hang, Xu; Jun, Zhao

    2018-05-01

    Adaptive angle-Doppler compensation method extract the requisite information based on the data itself adaptively, thus avoiding the problem of performance degradation caused by inertia system error. However, this method requires estimation and egiendecomposition of sample covariance matrix, which has a high computational complexity and limits its real-time application. In this paper, an adaptive angle Doppler compensation method based on projection approximation subspace tracking (PAST) is studied. The method uses cyclic iterative processing to quickly estimate the positions of the spectral center of the maximum eigenvector of each range cell, and the computational burden of matrix estimation and eigen-decompositon is avoided, and then the spectral centers of all range cells is overlapped by two dimensional compensation. Simulation results show the proposed method can effectively reduce the no homogeneity of airborne bistatic radar, and its performance is similar to that of egien-decomposition algorithms, but the computation load is obviously reduced and easy to be realized.

  7. Colour Doppler ultrasound of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, C.J.; Sriprasad, S.; Sidhu, P.S. E-mail: paulsidhu@compuserve.com

    2003-07-01

    Because it is a superficial structure, the penis is ideally suited to ultrasound imaging. A number of disease processes, including Peyronie's disease, penile fractures and penile tumours, are clearly visualized with ultrasound. An assessment of priapism can also be made using spectral Doppler waveform technology. Furthermore, dynamic assessment of cavernosal arterial changes after pharmaco-stimulation allows diagnosis of arterial and venogenic causes for impotence. This pictorial review illustrates the range of diseases encountered with ultrasound of the penis.

  8. Doppler Lidar Wind Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Newsom, R. K. [DOE ARM Climate Research Facility, Washington, DC (United States); Sivaraman, C. [DOE ARM Climate Research Facility, Washington, DC (United States); Shippert, T. R. [DOE ARM Climate Research Facility, Washington, DC (United States); Riihimaki, L. D. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2015-07-01

    Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. Raw data from a scanning coherent Doppler lidar system can be processed to generate accurate height-resolved measurements of wind speed and direction in the atmospheric boundary layer.

  9. Theoretical study of electromagnetically induced transparency in a five-level atom and application to Doppler-broadened and Doppler-free Rb atoms

    International Nuclear Information System (INIS)

    Bhattacharyya, Dipankar; Ray, Biswajit; Ghosh, Pradip N

    2007-01-01

    We report theoretical studies of a Λ-type five-level atomic system. The density matrix equations are set up and solved numerically to obtain the probe absorption line shape of Rb D 2 transitions for cold (Doppler-free) and room temperature (Doppler-broadened) atoms. Simulated spectra for Doppler-broadened systems lead to four velocity-selective dips along with an electromagnetic induced transparency (EIT) peak as observed earlier from the co-propagating pump-probe spectroscopy of Rb D 2 transitions. Effects of pump power and spontaneous decay rate from the upper levels on the simulated spectra are also studied. For cold atoms a very pronounced EIT peak is observed when the pump frequency is on resonance with one allowed transition. We find that lower pump power leads to a much sharper EIT signal in this case. A simulated dispersion curve shows a rapid variation of the refractive index that may lead to a sharp reduction of the group velocity of photons

  10. Region-of-interest analyses of one-dimensional biomechanical trajectories: bridging 0D and 1D theory, augmenting statistical power

    Directory of Open Access Journals (Sweden)

    Todd C. Pataky

    2016-11-01

    Full Text Available One-dimensional (1D kinematic, force, and EMG trajectories are often analyzed using zero-dimensional (0D metrics like local extrema. Recently whole-trajectory 1D methods have emerged in the literature as alternatives. Since 0D and 1D methods can yield qualitatively different results, the two approaches may appear to be theoretically distinct. The purposes of this paper were (a to clarify that 0D and 1D approaches are actually just special cases of a more general region-of-interest (ROI analysis framework, and (b to demonstrate how ROIs can augment statistical power. We first simulated millions of smooth, random 1D datasets to validate theoretical predictions of the 0D, 1D and ROI approaches and to emphasize how ROIs provide a continuous bridge between 0D and 1D results. We then analyzed a variety of public datasets to demonstrate potential effects of ROIs on biomechanical conclusions. Results showed, first, that a priori ROI particulars can qualitatively affect the biomechanical conclusions that emerge from analyses and, second, that ROIs derived from exploratory/pilot analyses can detect smaller biomechanical effects than are detectable using full 1D methods. We recommend regarding ROIs, like data filtering particulars and Type I error rate, as parameters which can affect hypothesis testing results, and thus as sensitivity analysis tools to ensure arbitrary decisions do not influence scientific interpretations. Last, we describe open-source Python and MATLAB implementations of 1D ROI analysis for arbitrary experimental designs ranging from one-sample t tests to MANOVA.

  11. Development of the medical apparatus for Doppler-controlled treatment of hemorrhoids using laser coagulation

    Directory of Open Access Journals (Sweden)

    Nikolay A. Gryaznov

    2017-12-01

    Full Text Available In the article authors present the concept of the surgical manipulator delivering laser radiation to the target area. For the implementation of Doppler-controlled treatment of hemorrhoids by laser coagulation, an important circumstance is the necessity to realize by means of the dopplerograph the possibility of controlling the efficiency of coagulation of the pathological vessel immediately after the impact, which will create the prerequisites for the formation of a program cycle with the inclusion of control elements by feedback. In this regard, the structure of the laser medical apparatus is developed, which allows determining the location, size and flow of arterial and venous vessels, performing laser coagulation of pathologically damaged sites under constant Doppler control. The developed adaptive power management system includes several functional units for the processing of the data from ultrasound scanner and the Doppler. Medical apparatus for minimally invasive treatment of hemorrhoids based on the laser coagulator and ultrasound Doppler will allow performing surgeries in automated and half-automated modes. The suggested medical apparatus helps to determine pathological vessels, choose the required radiation mode and provides vessel obliteration. Successful realization of constructive combination of real-time diagnostics and surgical manipulation with a laser can result in a unique minimally invasive solution to treat hemorrhoids that currently doesn’t have analogues.

  12. Estimation of the hydraulic conductivity of a two-dimensional fracture network using effective medium theory and power-law averaging

    Science.gov (United States)

    Zimmerman, R. W.; Leung, C. T.

    2009-12-01

    Most oil and gas reservoirs, as well as most potential sites for nuclear waste disposal, are naturally fractured. In these sites, the network of fractures will provide the main path for fluid to flow through the rock mass. In many cases, the fracture density is so high as to make it impractical to model it with a discrete fracture network (DFN) approach. For such rock masses, it would be useful to have recourse to analytical, or semi-analytical, methods to estimate the macroscopic hydraulic conductivity of the fracture network. We have investigated single-phase fluid flow through generated stochastically two-dimensional fracture networks. The centers and orientations of the fractures are uniformly distributed, whereas their lengths follow a lognormal distribution. The aperture of each fracture is correlated with its length, either through direct proportionality, or through a nonlinear relationship. The discrete fracture network flow and transport simulator NAPSAC, developed by Serco (Didcot, UK), is used to establish the “true” macroscopic hydraulic conductivity of the network. We then attempt to match this value by starting with the individual fracture conductances, and using various upscaling methods. Kirkpatrick’s effective medium approximation, which works well for pore networks on a core scale, generally underestimates the conductivity of the fracture networks. We attribute this to the fact that the conductances of individual fracture segments (between adjacent intersections with other fractures) are correlated with each other, whereas Kirkpatrick’s approximation assumes no correlation. The power-law averaging approach proposed by Desbarats for porous media is able to match the numerical value, using power-law exponents that generally lie between 0 (geometric mean) and 1 (harmonic mean). The appropriate exponent can be correlated with statistical parameters that characterize the fracture density.

  13. Fracture size and transmissivity correlations: Implications for transport simulations in sparse three-dimensional discrete fracture networks following a truncated power law distribution of fracture size

    Science.gov (United States)

    Hyman, J.; Aldrich, G. A.; Viswanathan, H. S.; Makedonska, N.; Karra, S.

    2016-12-01

    We characterize how different fracture size-transmissivity relationships influence flow and transport simulations through sparse three-dimensional discrete fracture networks. Although it is generally accepted that there is a positive correlation between a fracture's size and its transmissivity/aperture, the functional form of that relationship remains a matter of debate. Relationships that assume perfect correlation, semi-correlation, and non-correlation between the two have been proposed. To study the impact that adopting one of these relationships has on transport properties, we generate multiple sparse fracture networks composed of circular fractures whose radii follow a truncated power law distribution. The distribution of transmissivities are selected so that the mean transmissivity of the fracture networks are the same and the distributions of aperture and transmissivity in models that include a stochastic term are also the same.We observe that adopting a correlation between a fracture size and its transmissivity leads to earlier breakthrough times and higher effective permeability when compared to networks where no correlation is used. While fracture network geometry plays the principal role in determining where transport occurs within the network, the relationship between size and transmissivity controls the flow speed. These observations indicate DFN modelers should be aware that breakthrough times and effective permeabilities can be strongly influenced by such a relationship in addition to fracture and network statistics.

  14. Three-dimensional sponge-like architectured cupric oxides as high-power and long-life anode material for lithium rechargeable batteries

    International Nuclear Information System (INIS)

    Choi, Chung Seok; Park, Young-Uk; Kim, Hyungsub; Kim, Na Rae; Kang, Kisuk; Lee, Hyuck Mo

    2012-01-01

    Cupric oxide (CuO) nanoparticles (NPs) with three-dimensional (3D) sponge structure are obtained through the sintering of Cu NPs at 360 °C. Their morphology is analyzed by transmission electron microscopy (TEM) and scanning electron microscopy (SEM), and their crystal structure is checked by X-ray diffraction. CuO NPs have a 3D porous structure. The NPs are assembled to form larger secondary particles with many empty spaces among them, and they have a CuO phase after the heat treatment. CuO NPs with this novel architecture exhibit good electrochemical performance as anode material. The anode material with a sponge-like structure is prepared at 360 °C, as the Li-ion battery exhibits a high electrochemical capacity of 674 mAh g −1 . When the sample is sintered at 360 °C, the charge/discharge capacities increase gradually and cycle up to 50 cycles at a C/10 rate, exhibiting excellent rate capability compared with earlier reported CuO/CuO-composite anodes. Electrochemical impedance spectroscopy (EIS) measurements suggest that the superior electrical conductivity of the sample sintered at 360 °C is the main factor responsible for the improved power capability.

  15. Low complexity joint estimation of reflection coefficient, spatial location, and Doppler shift for MIMO-radar by exploiting 2D-FFT

    KAUST Repository

    Jardak, Seifallah

    2014-10-01

    In multiple-input multiple-output (MIMO) radar, to estimate the reflection coefficient, spatial location, and Doppler shift of a target, maximum-likelihood (ML) estimation yields the best performance. For this problem, the ML estimation requires the joint estimation of spatial location and Doppler shift, which is a two dimensional search problem. Therefore, the computational complexity of ML estimation is prohibitively high. In this work, to estimate the parameters of a target, a reduced complexity optimum performance algorithm is proposed, which allow two dimensional fast Fourier transform to jointly estimate the spatial location and Doppler shift. To asses the performances of the proposed estimators, the Cramér-Rao-lower-bound (CRLB) is derived. Simulation results show that the mean square estimation error of the proposed estimators achieve the CRLB. © 2014 IEEE.

  16. The image of urachus adenocarcinoma on Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Oyar, Orhan E-mail: o_oyar@hotmail.com; Yesildag, Ahmet; Gulsoy, Ufuk Kemal; Perk, Hakki

    2002-10-01

    Malignant urachal lesions are exceedingly rare and occur predominantly in adult life. In this case report, an adult patient with urachal carcinoma is presented with abdominal plain film, intravenous urography, gray-scale ultrasonography (US), Doppler US, and computed tomography (CT). Doppler US successfully showed the neovascularity with low resistive index value in the urachus tumor. We believe that Doppler US examination is helpful in the differential diagnosis of urachal carcinoma.

  17. Doppler US evaluation of the hypertensive portal system

    International Nuclear Information System (INIS)

    Needleman, L.; Kurtz, A.B.; Bezzi, M.; Rifkin, M.D.; Pasto, M.E.; Pennell, R.G.; Baltarowich, O.H.; Goldberg, B.B.

    1986-01-01

    In patients with known portal hypertension, pulsed Doppler US was used for qualitative and directional evaluation of flow in the portal venous system and collateral vessels. Most patients had normal hepatopetal flow. Doppler US revealed the following abnormal blood flow patterns: hepatofugal portal flow, bidirectional portal flow, intrahepatic portal shunting, flow in portasystemic collaterals, and hepatic vein obstruction. Doppler US can provide important clinical information in the evaluation of portal hypertension

  18. New Insights from Inside-Out Doppler Tomography

    Directory of Open Access Journals (Sweden)

    E. J. Kotze

    2015-02-01

    Full Text Available We present preliminary results from our investigation into using an “inside-out” velocity space for creating a Doppler tomogram. The aim is to transpose the inverted appearance of the Cartesian velocity space used in normal Doppler tomography. In a comparison between normal and inside-out Doppler tomograms of cataclysmic variables, we show that the inside-out velocity space has the potential to produce new insights into the accretion dynamics in these systems.

  19. Evaluating Peripheral Vascular Injuries: Is Color Doppler Enough for Diagnosis?

    Directory of Open Access Journals (Sweden)

    Mohd Lateef Wani

    2014-03-01

    Full Text Available Background:: Vascular injury poses a serious threat to limb and life. Thus, diagnosis should be made immediately with minimally invasive methods. Doppler is a good aid in diagnosis of vascular injury. Methods:: The present prospective study was conducted on 150 patients who presented with soft signs (the signs which are suggestive but not confirmatory of vascular injury. They were subjected to color Doppler examination before exploration. The patients with the features of vascular injury on color Doppler were subjected to exploration. On the other hand, those who had normal Doppler were subjected to CT- angiography. Then, the findings of the exploration were matched with those of color Doppler. The data were analyzed using the SPSS statistical software. Results:: Out of the 150 Doppler examinations, 110 (73.33% were reported as positive, while 40 were reported as negative for vascular injury. These were subjected to CT-angiography and seven of them had the features of vascular injury on CT-angiography. All the patients with positive Doppler or CT angiography findings were subjected to exploration. Doppler had a sensitivity of 94% and specificity of 82.5% in diagnosis of vascular injury using Binary classification test. Conclusions:: Color Doppler is an easily available, reliable, and handy method of diagnosing a vascular injury. It has a very high sensitivity and specificity in diagnosis of vascular injuries.

  20. Coherent Detection in Laser Doppler Velocimeters

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner

    1974-01-01

    , but intelligible particle picture of electromagnetic waves. The analysis is carried out with special emphasis on the heterodyning process in the laser Doppler velocimeter (LDV) because the main purpose of this article is to provide a better understanding of this instrument. An aid for this purpose......The possibility of heterodyning between electromagnetic waves scattered by particles separated in space is explained from a classical point of view and from a quantum mechanical point of view. The last description being carried out using only the Heisenberg uncertainty principle and a rather coarse...

  1. Digital setup for Doppler broadening spectroscopy

    International Nuclear Information System (INIS)

    Cizek, J; Vlcek, M; Prochazka, I

    2011-01-01

    New digital spectrometer for measurement of the Doppler shift of annihilation photons was developed and tested in this work. Digital spectrometer uses a fast 12-bit digitizer for direct sampling of signals from HPGe detectors. Analysis of sampled waveforms is performed off-line in software. Performance of the new digital setup was compared with its traditional analogue counterpart. Superior energy resolution was achieved in the digital setup. Moreover, the digital setup allows for a better control of the shape of detector signals. This enables to eliminate undesired signals damaged by pile-up effects or by ballistic deficit.

  2. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Luca Giugno

    2007-05-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  3. A new formulation for the Doppler broadening function relaxing the approximations of Beth–Plackzec

    International Nuclear Information System (INIS)

    Palma, Daniel A.P.; Gonçalves, Alessandro C.; Martinez, Aquilino S.; Mesquita, Amir Z.

    2016-01-01

    Highlights: • One of the Beth–Placzek approximation were relaxed. • An additional term in the form of an integral is obtained. • A new mathematical formulation for the Doppler broadening function is proposed. - Abstract: In all nuclear reactors some neutrons can be absorbed in the resonance region and, in the design of these reactors, an accurate treatment of the resonant absorptions is essential. Apart from that, the resonant absorption varies with fuel temperature due to the Doppler broadening of the resonances. The thermal agitation movement in the reactor core is adequately represented in the microscopic cross-section of the neutron-core interaction through the Doppler broadening function. This function is calculated numerically in modern systems for the calculation of macro-group constants, necessary to determine the power distribution of a nuclear reactor. It can also be applied to the calculation of self-shielding factors to correct the measurements of the microscopic cross-sections through the activation technique and used for the approximate calculations of the resonance integrals in heterogeneous fuel cells. In these types of application we can point at the need to develop precise analytical approximations for the Doppler broadening function to be used in the calculation codes that calculate the values of this function. However, the Doppler broadening function is based on a series of approximations proposed by Beth–Plackzec. In this work a relaxation of these approximations is proposed, generating an additional term in the form of an integral. Analytical solutions of this additional term are discussed. The results obtained show that the new term is important for high temperatures.

  4. A novel decision tree approach based on transcranial Doppler sonography to screen for blunt cervical vascular injuries.

    Science.gov (United States)

    Purvis, Dianna; Aldaghlas, Tayseer; Trickey, Amber W; Rizzo, Anne; Sikdar, Siddhartha

    2013-06-01

    Early detection and treatment of blunt cervical vascular injuries prevent adverse neurologic sequelae. Current screening criteria can miss up to 22% of these injuries. The study objective was to investigate bedside transcranial Doppler sonography for detecting blunt cervical vascular injuries in trauma patients using a novel decision tree approach. This prospective pilot study was conducted at a level I trauma center. Patients undergoing computed tomographic angiography for suspected blunt cervical vascular injuries were studied with transcranial Doppler sonography. Extracranial and intracranial vasculatures were examined with a portable power M-mode transcranial Doppler unit. The middle cerebral artery mean flow velocity, pulsatility index, and their asymmetries were used to quantify flow patterns and develop an injury decision tree screening protocol. Student t tests validated associations between injuries and transcranial Doppler predictive measures. We evaluated 27 trauma patients with 13 injuries. Single vertebral artery injuries were most common (38.5%), followed by single internal carotid artery injuries (30%). Compared to patients without injuries, mean flow velocity asymmetry was higher for single internal carotid artery (P = .003) and single vertebral artery (P = .004) injuries. Similarly, pulsatility index asymmetry was higher in single internal carotid artery (P = .015) and single vertebral artery (P = .042) injuries, whereas the lowest pulsatility index was elevated for bilateral vertebral artery injuries (P = .006). The decision tree yielded 92% specificity, 93% sensitivity, and 93% correct classifications. In this pilot feasibility study, transcranial Doppler measures were significantly associated with the blunt cervical vascular injury status, suggesting that transcranial Doppler sonography might be a viable bedside screening tool for trauma. Patient-specific hemodynamic information from transcranial Doppler assessment has the potential to alter

  5. Compact, High Energy 2-micron Coherent Doppler Wind Lidar Development for NASA's Future 3-D Winds Measurement from Space

    Science.gov (United States)

    Singh, Upendra N.; Koch, Grady; Yu, Jirong; Petros, Mulugeta; Beyon, Jeffrey; Kavaya, Michael J.; Trieu, Bo; Chen, Songsheng; Bai, Yingxin; Petzar, paul; hide

    2010-01-01

    This paper presents an overview of 2-micron laser transmitter development at NASA Langley Research Center for coherent-detection lidar profiling of winds. The novel high-energy, 2-micron, Ho:Tm:LuLiF laser technology developed at NASA Langley was employed to study laser technology currently envisioned by NASA for future global coherent Doppler lidar winds measurement. The 250 mJ, 10 Hz laser was designed as an integral part of a compact lidar transceiver developed for future aircraft flight. Ground-based wind profiles made with this transceiver will be presented. NASA Langley is currently funded to build complete Doppler lidar systems using this transceiver for the DC-8 aircraft in autonomous operation. Recently, LaRC 2-micron coherent Doppler wind lidar system was selected to contribute to the NASA Science Mission Directorate (SMD) Earth Science Division (ESD) hurricane field experiment in 2010 titled Genesis and Rapid Intensification Processes (GRIP). The Doppler lidar system will measure vertical profiles of horizontal vector winds from the DC-8 aircraft using NASA Langley s existing 2-micron, pulsed, coherent detection, Doppler wind lidar system that is ready for DC-8 integration. The measurements will typically extend from the DC-8 to the earth s surface. They will be highly accurate in both wind magnitude and direction. Displays of the data will be provided in real time on the DC-8. The pulsed Doppler wind lidar of NASA Langley Research Center is much more powerful than past Doppler lidars. The operating range, accuracy, range resolution, and time resolution will be unprecedented. We expect the data to play a key role, combined with the other sensors, in improving understanding and predictive algorithms for hurricane strength and track. 1

  6. Doppler ultrasound scan during normal gestation: umbilical circulation; Ecografia Doppler en la gestacion normal: circulacion umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J. [Hospital Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs.

  7. Radial correlation length measurements on ASDEX Upgrade using correlation Doppler reflectometry

    International Nuclear Information System (INIS)

    Schirmer, J; Conway, G D; Holzhauer, E; Suttrop, W; Zohm, H

    2007-01-01

    The technique of correlation Doppler reflectometry for providing radial correlation length L r measurements is explored in this paper. Experimental L r measurements are obtained using the recently installed dual channel Doppler reflectometer system on ASDEX Upgrade. The experimental measurements agree well with theory and with L r measured on other fusion devices using different diagnostic techniques. A strong link between L r and plasma confinement could be observed. From the L- to the H-mode, an increase in the absolute value of E r shear was detected at the same plasma edge region where a decrease in L r was measured. This observation is in agreement with theoretical models which predict that an increase in the absolute shear suppresses turbulent fluctuations in the plasma, leading to a reduction in L r . Furthermore, L r decreases from the plasma core to the edge and decreases with increasing plasma triangularity δ. The experimental results have been extensively modelled using a 2-dimensional finite difference time domain code. The simulations confirm that Doppler reflectometry provides robust radial correlation lengths of the turbulence with high resolution and suggests that L r is independent of the turbulence wavenumber k p erpendicular and its fluctuation level

  8. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of); Hwang, Hee Yong [Choong Ang Gil Hospital, Incheon (Korea, Republic of)

    1995-06-15

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  9. Enormous periodic doppler shifts in SS 433

    International Nuclear Information System (INIS)

    Margon, B.; Ford, H.C.; Grandi, S.A.; Stone, R.P.S.

    1979-01-01

    We have previously reported prominent ''moving' emission lines in the visible spectrum of Stephenson-Sanduleak 433, the optical counterpart of a variable radio and X-ray source. Further observations show that despite the implausible velocities and changes in velocities implied if the moving features are interpreted as Doppler-shifted Balmer lines, this explanation is indeed correct. Spectroscopy of SS 433 on 51 mights in 1978--1979 reveals that the unidentified features are two sets of Balmer and He I lines, one with large and changing redshift, and the other with large and changing blueshift. Combining our data with published earlier observations, we obtain Doppler shifts on 80 nights in the period 1978 June to 1979 June. These data indicate that the velocity variations are cyclical, repeating in both the blueshift and redshift systems with a period of 164 +- 3 days. The two systems have thus far been observed to reach maximum positive and negative radial velocities of +50,000 and -35,000 km s -1 , respectively, are always symmetric about redshift z=0.04, and follow roughly sinusoidal velocity curves. We discuss in addition a variety of interesting short-term spectroscopic details, including minor but highly significant deviations of the radial velocity from the sinusoid, and nightly line profile changes, sometimes appearing as mirror-image events in the redshift and blueshift systems. The behavior of SS 433 is unprecedented

  10. Speed of light demonstration using Doppler beat

    Science.gov (United States)

    Bernal, Luis; Bilbao, Luis

    2018-05-01

    From an apparatus previously designed for measuring the Doppler shift using a rotating mirror, an improved, versatile version was developed for speed of light demonstrations in a classroom or a teaching laboratory. By adding a second detector and adequate beam-splitter and mirrors, three different configurations are easily assembled. One configuration is used for time-of-flight measurements between a near and a far detector, allowing one to measure the speed of light provided that the path length between detectors is known. Another variation is the interferometric method obtained by superposing the far and near signals in such a way that a minimum of the combined signal is obtained when the time delay makes the signals arrive out of phase by π radians. Finally, the standard Doppler configuration allows the measurement of the frequency beat as a function of the rotation frequency. The main advantages of the apparatus are (a) the experimental setup is simple and completely accessible to undergraduate students, (b) the light is visible, students can see the rays, which, with the use of appropriate screens, can be blocked at any point along their paths, (c) the experiment can take place entirely within the teaching laboratory or demonstration room (using the interferometric method, the shortest distance to the far mirror was as small as 0.5 m), and (d) different configurations can be built, including some economical setups within the budget of teaching laboratories.

  11. Parametric Investigation of Laser Doppler Microphones

    Science.gov (United States)

    Daoud, M.; Naguib, A.

    2002-11-01

    The concept of a Laser Doppler Microphone (LDM) is based on utilizing the Doppler frequency shift of a focused laser beam to measure the unsteady velocity of the center point of a flexible polymer diaphragm that is mounted on top of a hole and subjected to the unsteady pressure. Time integration of the velocity signal yields a time series of the diaphragm displacement, which can be converted to pressure from knowledge of the sensor's deflection sensitivity. In our APS/DFD presentation last year, the stringent frequency resolution requirement of these new sensors and methods to meet this requirement were discussed. Here, the dependence of the sensor characteristics (sensitivity, bandwidth, and noise floor) on various significant parameters is investigated in detail by calibrating the sensor in a plane wave tube in the frequency range of 50 - 5000 Hz. Parameters investigated include sensor diaphragm material and thickness, sensor size, damping of the diaphragm motion and laser beam spot size. The results shed light on the operating limits of the new sensor and demonstrate its ability to conduct high-spatial-resolution measurements in typical high-Reynolds-number test facilities. Moreover, calibrated LDM sensors were used to conduct measurements in a separating/reattaching flow and the results are compared to classical electret-type microphones with a similar sensing diameter.

  12. Laser doppler velocimetry and confined flows

    Directory of Open Access Journals (Sweden)

    Ilić Jelena T.

    2017-01-01

    Full Text Available Finding the mode, in which two component laser Doppler velocimetry can be applied to flows confined in cylindrical tubes or vessels, was the aim of this study. We have identified principle issues that influence the propagation of laser beams in laser Doppler velocimetry system, applied to flow confined in cylindrical tube. Among them, the most important are influences of fluid and wall refractive indices, wall thickness and internal radius ratio and beam intersection angle. In analysis of the degrees of these influences, we have applied mathematical model, based on geometrical optics. The separation of measurement volumes, that measure different velocity components, has been recognized as the main drawback. To overcome this, we propose a lens with dual focal length – primary focal length for the measurement of one velocity component and secondary focal length for the measurement of the other velocity component. We present here the procedure for calculating the optimal value of secondary focal length, depending on experimental set-up parameters. The mathematical simulation of the application of the dual focal length lens, for chosen cases presented here, confirmed the accuracy of the proposed procedure.

  13. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    International Nuclear Information System (INIS)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan; Hwang, Hee Yong

    1995-01-01

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  14. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    Directory of Open Access Journals (Sweden)

    Lawrence H. Lin

    Full Text Available Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: “Gestational trophoblastic disease AND Ultrasonography, Doppler.” Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1 Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2 There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3 Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4 Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. CONCLUSION: Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  15. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    Science.gov (United States)

    Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V

    2015-12-01

    Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: "Gestational trophoblastic disease AND Ultrasonography, Doppler." Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1) Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2) There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3) Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4) Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  16. Coherent optical transients observed in rubidium atomic line filtered Doppler velocimetry experiments

    Energy Technology Data Exchange (ETDEWEB)

    Fajardo, Mario E., E-mail: mario.fajardo@eglin.af.mil; Molek, Christopher D.; Vesely, Annamaria L. [Air Force Research Laboratory, Munitions Directorate, Ordnance Division, Energetic Materials Branch, AFRL/RWME, 2306 Perimeter Road, Eglin AFB, Florida 32542-5910 (United States)

    2015-10-14

    We report the first successful results from our novel Rubidium Atomic Line Filtered (RALF) Doppler velocimetry apparatus, along with unanticipated oscillatory signals due to coherent optical transients generated within pure Rb vapor cells. RALF is a high-velocity and high-acceleration extension of the well-known Doppler Global Velocimetry (DGV) technique for constructing multi-dimensional flow velocity vector maps in aerodynamics experiments [H. Komine, U.S. Patent No. 4,919,536 (24 April 1990)]. RALF exploits the frequency dependence of pressure-broadened Rb atom optical absorptions in a heated Rb/N{sub 2} gas cell to encode the Doppler shift of reflected near-resonant (λ{sub 0} ≈ 780.24 nm) laser light onto the intensity transmitted by the cell. The present RALF apparatus combines fiber optic and free-space components and was built to determine suitable operating conditions and performance parameters for the Rb/N{sub 2} gas cells. It yields single-spot velocities of thin laser-driven-flyer test surfaces and incorporates a simultaneous Photonic Doppler Velocimetry (PDV) channel [Strand et al., Rev. Sci. Instrum. 77, 083108 (2006)] for validation of the RALF results, which we demonstrate here over the v = 0 to 1 km/s range. Both RALF and DGV presume the vapor cells to be simple Beer's Law optical absorbers, so we were quite surprised to observe oscillatory signals in experiments employing low pressure pure Rb vapor cells. We interpret these oscillations as interference between the Doppler shifted reflected light and the Free Induction Decay (FID) coherent optical transient produced within the pure Rb cells at the original laser frequency; this is confirmed by direct comparison of the PDV and FID signals. We attribute the different behaviors of the Rb/N{sub 2} vs. Rb gas cells to efficient dephasing of the atomic/optical coherences by Rb-N{sub 2} collisions. The minimum necessary N{sub 2} buffer gas density ≈0.3 amagat translates into a

  17. Novel investigation of the different Omni-direction-guide-vane angles effects on the urban vertical axis wind turbine output power via three-dimensional numerical simulation

    International Nuclear Information System (INIS)

    Shahizare, B.; Nik-Ghazali, N.; Chong, W.T.; Tabatabaeikia, S.; Izadyar, Nima; Esmaeilzadeh, Alireza

    2016-01-01

    Highlights: • Investigation of the Omni-direction-guide-vane impacts on the VAWT performance. • Obtain the best position of the guide vane angles in order to achieve the maximum performance. • Validation of the 3D computational fluid dynamics with experimental data. • Acquire the optimal Omni-direction-guide-vane based on numerical simulation results. - Abstract: The aim of this study is to present the effects of different Omni-direction-guide-vane (ODGV) angles on the performance of the vertical axis wind turbine (VAWT). For this purpose, five different straight-bladed VAWTs have been simulated via three-dimensional (3D) computational fluid dynamics (CFD). Hence, the VAWT without ODGV covering, were simulated and validated via CFD and experimental fluid dynamics (EFD) data, respectively in the first step. Indeed, grid and time step independency test as well as the effect of domain size, have been conducted and a suitable agreement was found based on comparison of the CFD and EFD results. In the next step, the VAWT was shrouded by ODGV cover and the whole system was simulated for 52 angles of the ODGV in four different tip speed ratios (TSR), to investigate the impact of guide vanes angles on the VAWT performance. Results of this study indicated that output power of the VAWT with α = 20° and β = 55° ODGV guide vanes, was improved 40.9%, 36.5%, 35.3% and 33.2%, respectively in four different TSR including 0.745, 1.091, 1.901 and 2.53.

  18. Two-Dimensional Mapping of the Calculated Fission Power for the Full-Size Fuel Plate Experiment Irradiated in the Advanced Test Reactor

    Science.gov (United States)

    Chang, G. S.; Lillo, M. A.

    2009-08-01

    The National Nuclear Security Administrations (NNSA) Reduced Enrichment for Research and Test Reactors (RERTR) program assigned to the Idaho National Laboratory (INL) the responsibility of developing and demonstrating high uranium density research reactor fuel forms to enable the use of low enriched uranium (LEU) in research and test reactors around the world. A series of full-size fuel plate experiments have been proposed for irradiation testing in the center flux trap (CFT) position of the Advanced Test Reactor (ATR). These full-size fuel plate tests are designated as the AFIP tests. The AFIP nominal fuel zone is rectangular in shape having a designed length of 21.5-in (54.61-cm), width of 1.6-in (4.064-cm), and uniform thickness of 0.014-in (0.03556-cm). This gives a nominal fuel zone volume of 0.482 in3 (7.89 cm3) per fuel plate. The AFIP test assembly has two test positions. Each test position is designed to hold 2 full-size plates, for a total of 4 full-size plates per test assembly. The AFIP test plates will be irradiated at a peak surface heat flux of about 350 W/cm2 and discharged at a peak U-235 burn-up of about 70 at.%. Based on limited irradiation testing of the monolithic (U-10Mo) fuel form, it is desirable to keep the peak fuel temperature below 250°C to achieve this, it will be necessary to keep plate heat fluxes below 500 W/cm2. Due to the heavy U-235 loading and a plate width of 1.6-in (4.064-cm), the neutron self-shielding will increase the local-to-average-ratio (L2AR) fission power near the sides of the fuel plates. To demonstrate that the AFIP experiment will meet the ATR safety requirements, a very detailed 2-dimensional (2D) Y-Z fission power profile was evaluated in order to best predict the fuel plate temperature distribution. The ability to accurately predict fuel plate power and burnup are essential to both the design of the AFIP tests as well as evaluation of the irradiated fuel performance. To support this need, a detailed MCNP Y

  19. CONSTRAINING HIGH-SPEED WINDS IN EXOPLANET ATMOSPHERES THROUGH OBSERVATIONS OF ANOMALOUS DOPPLER SHIFTS DURING TRANSIT

    International Nuclear Information System (INIS)

    Miller-Ricci Kempton, Eliza; Rauscher, Emily

    2012-01-01

    Three-dimensional (3D) dynamical models of hot Jupiter atmospheres predict very strong wind speeds. For tidally locked hot Jupiters, winds at high altitude in the planet's atmosphere advect heat from the day side to the cooler night side of the planet. Net wind speeds on the order of 1-10 km s –1 directed towards the night side of the planet are predicted at mbar pressures, which is the approximate pressure level probed by transmission spectroscopy. These winds should result in an observed blueshift of spectral lines in transmission on the order of the wind speed. Indeed, Snellen et al. recently observed a 2 ± 1 km s –1 blueshift of CO transmission features for HD 209458b, which has been interpreted as a detection of the day-to-night (substellar to anti-stellar) winds that have been predicted by 3D atmospheric dynamics modeling. Here, we present the results of a coupled 3D atmospheric dynamics and transmission spectrum model, which predicts the Doppler-shifted spectrum of a hot Jupiter during transit resulting from winds in the planet's atmosphere. We explore four different models for the hot Jupiter atmosphere using different prescriptions for atmospheric drag via interaction with planetary magnetic fields. We find that models with no magnetic drag produce net Doppler blueshifts in the transmission spectrum of ∼2 km s –1 and that lower Doppler shifts of ∼1 km s –1 are found for the higher drag cases, results consistent with—but not yet strongly constrained by—the Snellen et al. measurement. We additionally explore the possibility of recovering the average terminator wind speed as a function of altitude by measuring Doppler shifts of individual spectral lines and spatially resolving wind speeds across the leading and trailing terminators during ingress and egress.

  20. Right Ventricular Doppler Echocardiographic Study of Indeterminate Form of Chagas Disease

    Directory of Open Access Journals (Sweden)

    Rogério Gomes Furtado

    2015-03-01

    Full Text Available Background: Patients with indeterminate form of Chagas disease/cardiac normality (ICD/CN exhibited normal electrocardiograms and chest X-rays; however, more sophisticated tests detected some degree of morphological and functional changes in the heart. Objective: To assess the prevalence of systolic and diastolic dysfunction of the right ventricle (RV in patients with ICD/CN. Methods: This was a case–control and prevalence study. Using Doppler two-dimensional echocardiography (2D, 92 patients were assessed and divided into two groups: group I (normal, n = 31 and group II (ICD/CN, n = 61. Results: The prevalence of RV systolic dysfunction in patients in groups I and II was as follows: fractional area change (0.0% versus 0.6%, mobility of the tricuspid annulus (0.0% versus 0.0%, and S-wave tissue Doppler (6.4% versus 26.0%, p = 0.016. The prevalence of global disorders such as the right myocardial performance index using tissue Doppler (16.1% versus 27.8%, p = 0.099 and pulsed Doppler (61.3% versus 68%, p = 0.141 and diastolic disorders such as abnormal relaxation (0.0% versus 6.0%, pseudonormal pattern (0.0% versus 0.0%, and restrictive pattern (0.0% versus 0.0% was not statistically different between groups. Conclusion: The prevalence of RV systolic dysfunction was estimated to be 26% (S wave velocity compared with other variables, suggesting incipient changes in RV systolic function in the ICD/CN group.

  1. Flow measurement by Laser Doppler Anemometry in a nuclear fuel assembly

    International Nuclear Information System (INIS)

    Kehoe, A.

    1984-12-01

    Development of a Laser Doppler Anemometer measurement system and its operation are examined in this research. The system is designed for flow measurement in laboratory models of nuclear fuel assemblies. Use of the system is demonstrated by measuring turbulent velocity profiles in the laboratory model at full scale reactor flow rates. The reactors at the Savanah River Plant (SRP) are heavy water moderated and operate at low temperatures and pressures. Reactor power is currently limited by the temperature of the water in the nuclear fuel assembly. These temperature limits are conservatively calculated without allowing for any turbulent mixing. This research incorporates the design, fabriction and operation of a plexiglas model fuel assembly for the purpose of making turbulent velocity measurement via a Laser Doppler Anemometer System

  2. Gamma-ray induced Doppler broadening and the determination of lifetimes of excited nuclear states

    International Nuclear Information System (INIS)

    Boerner, H.G.; Jolie, J.; Robinson, S.J.; Kessler, E.G.; Dewey, S.M.; Greene, G.; Deslattes, R.; Ulbig, S.; Lieb, K.P.; Casten, R.F.; Krusche, B.; Cizewski, J.A.

    1990-01-01

    Measurements of lifetimes of excited states in nuclei yield crucial information for sensitive tests of nuclear models. Here a novel method will be discussed which involves the GRID (Gamma Ray Induced Doppler broadening) technique, in which Doppler broadening is observed in a transition from a nucleus recoiling from the emission of a previous gamma ray. As the recoil energy is extremely small, ultra-high energy resolving power has to be used. To date all such experiments have been carried out at ILL using the GAMS4 double flat crystal spectrometer which is operated in a NIST-ILL collaboration. The method can be used for all lifetimes below a few picoseconds. The wide range of applicability, together with the very exhaustive set of data often obtained, is an advantage with respect to many other methods. The characteristic features of GRID will be discussed using some selected examples. 21 refs., 8 figs

  3. Quantitative measurement of blood flow dynamics in chorioallantoic membrane of chicken embryo using laser Doppler anemometry

    Science.gov (United States)

    Borozdova, M. A.; Stiukhina, E. S.; Sdobnov, A. A.; Fedosov, I. V.; Postnov, D. E.; Tuchin, V. V.

    2016-04-01

    We report the results on in ovo application of developed Laser Doppler Anemometer (LDA) device. The chorioallantoic membrane (CAM) of 9-13 days chicken embryos was used as a biological model that allows an easy access to both arterial and venous vessels of different size. The key point of our study was to find out how the periodic and aperiodic pulsations of blood flow (which are inevitable in living organism) will affect the LDA functions and measuring capability. Specifically, we (i) developed the technique to extract and refine the pulse rhythm from the signal received from a vessel, and (ii) analyzed the changes in power spectra of LDA signal that are caused by heart beating and considerably complicate the reliable measurement of Doppler shift. Our main conclusion is that the algorithm of LDA data processing need to be improved, and this possibly can be done by counting the information on current phase of cardiac cycle.

  4. Utilisation of the Rapsodie reactor for the measurement of the doppler effect

    International Nuclear Information System (INIS)

    Zaleski, C.P.; Abdon, R.; Ladet, J.; Ping, I.; Steven, L.

    1964-01-01

    This report shows how a special loading of a 400 liters core in the reactor 'Rapsodie' could simulate the same neutronic conditions as those encountered in power fast reactors. Various methods designed to measure the Doppler effect in this core are described and compared. In particular, a computation of the errors involved is set. This computation would bring us to think that such an experiment could give a valid estimation of the Doppler coefficient of large fast reactors. The neutronic computations set for this study are described in an annex. - This report(the annex excepted) has already been presented by Freddy STORRER at the conference on breeding: Economics and safety in large fast breeder reactors at Argonne National Laboratory, october 1963 and published in the Proceedings (ANL 6792). (authors) [fr

  5. Development and Application of integrated monitoring platform for the Doppler Weather SA-BAND Radar

    Science.gov (United States)

    Zhang, Q.; Sun, J.; Zhao, C. C.; Chen, H. Y.

    2017-10-01

    The doppler weather SA-band radar is an important part of modern meteorological observation methods, monitoring the running status of radar and the data transmission is important.This paper introduced the composition of radar system and classification of radar data,analysed the characteristics and laws of the radar when is normal or abnormal. Using Macromedia Dreamweaver and PHP, developed the integrated monitoring platform for the doppler weather SA-band radar which could monitor the real-time radar system running status and important performance indicators such as radar power,status parameters and others on Web page,and when the status is abnormal it will trigger the audio alarm.

  6. The effectiveness of Doppler controlled hemorrhoidal artery ligation ...

    African Journals Online (AJOL)

    In this work, we discuss the preliminary results of the effectiveness of the hemorrhoidal artery ligation under control Doppler as a new technique for the treatment of hemorrhoids. We report the results of patients with hemorrhoids we have followed over a period of one year who were treated with HAL Doppler. The intra-and ...

  7. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines the... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550... include signal analysis and display equipment, patient and equipment supports, component parts, and...

  8. Micro-Doppler classification of riders and riderless horses

    Science.gov (United States)

    Tahmoush, David

    2014-05-01

    Micro-range Micro-Doppler can be used to isolate particular parts of the radar signature, and in this case we demonstrate the differences in the signature between a walking horse versus a walking horse with a rider. Using micro-range micro-Doppler, we can distinguish the radar returns from the rider as separate from the radar returns of the horse.

  9. Correlation between Spectral Index and Doppler Factor for a ...

    Indian Academy of Sciences (India)

    Abstract. Relativistic beaming effect is important for blazars. In a very recent work, γ-ray Doppler factors were calculated for a sample of Fermi blazars (Fan et al. 2013). In this work, we investigated the correlation between the Doppler factor and the effective spectral index, αOX, and found an anticorrelation between them.

  10. Compressive sensing for high resolution profiles with enhanced Doppler performance

    NARCIS (Netherlands)

    Anitori, L.; Hoogeboom, P.; Chevalier, F. Le; Otten, M.P.G.

    2012-01-01

    In this paper we demonstrate how Compressive Sensing (CS) can be used in pulse-Doppler radars to improve the Doppler performance while preserving range resolution. We investigate here two types of stepped frequency waveforms, the coherent frequency bursts and successive frequency ramps, which can be

  11. Comparison between Doppler Ultrasound and Biopsy Findings in ...

    African Journals Online (AJOL)

    Methods: We retrospectively studied a random sample of 188 kidney transplanted patients who had Doppler-ultrasound examination followed within two weeks by transplant biopsy. We evaluated the specificity and sensitivity of Doppler ultrasound in diagnosing rejection at different RI thresholds, using the reported biopsy ...

  12. Development of a reactivity worth correction scheme for the one-dimensional transient analysis

    International Nuclear Information System (INIS)

    Cho, J. Y.; Song, J. S.; Joo, H. G.; Kim, H. Y.; Kim, K. S.; Lee, C. C.; Zee, S. Q.

    2003-11-01

    This work is to develop a reactivity worth correction scheme for the MASTER one-dimensional (1-D) calculation model. The 1-D cross section variations according to the core state in the MASTER input file, which are produced for 1-D calculation performed by the MASTER code, are incorrect in most of all the core states except for exactly the same core state where the variations are produced. Therefore this scheme performs the reactivity worth correction factor calculations before the main 1-D transient calculation, and generates correction factors for boron worth, Doppler and moderator temperature coefficients, and control rod worth, respectively. These correction factors force the one dimensional calculation to generate the same reactivity worths with the 3-dimensional calculation. This scheme is applied to the control bank withdrawal accident of Yonggwang unit 1 cycle 14, and the performance is examined by comparing the 1-D results with the 3-D results. This problem is analyzed by the RETRAN-MASTER consolidated code system. Most of all results of 1-D calculation including the transient power behavior, the peak power and time are very similar with the 3-D results. In the MASTER neutronics computing time, the 1-D calculation including the correction factor calculation requires the negligible time comparing with the 3-D case. Therefore, the reactivity worth correction scheme is concluded to be very good in that it enables the 1-D calculation to produce the very accurate results in a few computing time

  13. Dimensional characteristics of welds performed on AISI 1045 steel by means of the application of high power diode laser; Caracteristicas dimensionales de soldadura formadas sobre el acero AISI 1045 mediante la aplicacion del laser diodo de alta potencia

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez-Castillo, A.; Pou, J.; Lusquinos, F.; Quintero, F.; Soto, R.; Boutinguiza, M.; Saavedra, M.; Perez-Amor, M.

    2004-07-01

    The named High Power diode Laser (HPDL), emits a beam of optical energy generated by diode stimulation and offers the capability of supplying levels of power up to 6 kW. The objective of this research work was to study the main welding variables and their effects on dimensional characteristics of the beads performed by means of application of this novel laser. The results obtained, show that HPDL, is an energy source able to perform welds on AISI 1045 steel plates under conduction mode, without any kind of mechanized preparation, preheating or post-weld treatment and, without filler metal application. (Author) 16 refs.

  14. Correlation between US and MRI for prenatal lung volumetry in diaphragmatic hernia, and use of Doppler to identify the ipsilateral lung cap

    Energy Technology Data Exchange (ETDEWEB)

    Castellote, Amparo; Mencho, Sandra; Cadavid, Lina; Piqueras, Joaquim; Enriquez, Goya [University Children' s Hospital Vall d' Hebron, Department of Pediatric Radiology, Barcelona (Spain); Carreras, Elena; Higueras, Teresa [University Hospital Vall d' Hebron, Department of Obstetrics and Gynecology, Barcelona (Spain)

    2011-12-15

    Pulmonary hypoplasia is a common cause of neonatal death. To describe the correlation between relative fetal lung volume (RFLV) and lung-to-head ratio (LHR) in fetuses with unilateral diaphragmatic hernia. Additionally, to describe identification of the ipsilateral lung cap by power Doppler. Single-institution study of consecutive fetuses with diaphragmatic hernia. LHR (by US) and RFLV (by MRI) were correlated in fetuses with and without an ipsilateral lung cap seen at MRI. In four, color/power Doppler was used to follow the pulmonary artery of the ipsilateral lung to identify the compressed cap. The study included 48 fetuses of 20-38 weeks' gestational age (mean, 26 weeks). Mean LHR was 1.52 (range, 0.6-3) in fetuses with a lung cap and 1.15 (range, 0.6-2.58) in fetuses without (P = 0.043). Mean RFLV was 47.4% (range, 18-80%) in fetuses with and 32.9% (range, 14-57%) in fetuses without a lung cap (P = 0.005). RFLV and LHR correlated (r = 0.41, P = 0.01 in those with a cap; r = 0.50, P = 0.05 in those without). Power Doppler identified the ipsilateral lung cap and pulsed Doppler confirmed pulmonary vascularization in four of four fetuses. LHR underestimates lung volume in fetuses with an ipsilateral lung cap. Power Doppler may be useful for identifying the cap. (orig.)

  15. Doppler time-of-flight imaging

    KAUST Repository

    Heidrich, Wolfgang

    2017-02-16

    Systems and methods for imaging object velocity are provided. In an embodiment, at least one Time-of-Flight camera is used to capture a signal representative of an object in motion over an exposure time. Illumination and modulation frequency of the captured motion are coded within the exposure time. A change of illumination frequency is mapped to measured pixel intensities of the captured motion within the exposure time, and information about a Doppler shift in the illumination frequency is extracted to obtain a measurement of instantaneous per pixel velocity of the object in motion. The radial velocity information of the object in motion can be simultaneously captured for each pixel captured within the exposure time. In one or more aspects, the illumination frequency can be coded orthogonal to the modulation frequency of the captured motion. The change of illumination frequency can correspond to radial object velocity.

  16. Phase Doppler anemometry as an ejecta diagnostic

    Science.gov (United States)

    Bell, D. J.; Chapman, D. J.

    2017-01-01

    When a shock wave is incident on a free surface, micron sized pieces of the material can be ejected from that surface. Phase Doppler Anemometry (PDA) is being developed to simultaneously measure the sizes and velocities of the individual shock induced ejecta particles; providing an important insight into ejecta phenomena. The results from experiments performed on the 13 mm bore light gas gun at the Institute of Shock Physics, Imperial College London are presented. Specially grooved tin targets were shocked at pressures of up to 14 GPa, below the melt on release pressure, to generate ejecta particles. These experiments are the first time that PDA has been successfully fielded on dynamic ejecta experiments. The results and current state of the art of the technique are discussed along with the future improvements required to optimise performance and increase usability.

  17. Doppler interpretation of quasar red shifts.

    Science.gov (United States)

    Zapolsky, H S

    1966-08-05

    The hypothesis that the quasistellar sources (quasars) are local objects moving with velocities close to the speed of light is examined. Provided there is no observational cutoff on apparent bolometric magnitude for the quasars, the transverse Doppler effect leads to the expectation of fewer blue shifts than red shifts for an isotropic distribution of velocities. Such a distribution also yields a function N(z), the number of objects with red shift less than z which is not inconsistent with the present data. On the basis of two extreme assumptions concerning the origin of such rapidly moving sources, we computed curves of red shift plotted against magnitude. In particular, the curve obtained on the assumption that the quasars originated from an explosion in or nearby our own galaxy is in as good agreement with the observations as the curve of cosmological red shift plotted against magnitude.

  18. Microscale Heat Conduction Models and Doppler Feedback

    International Nuclear Information System (INIS)

    Hawari, Ayman I.; Ougouag, Abderrafi

    2015-01-01

    The objective of this project is to establish an approach for providing the fundamental input that is needed to estimate the magnitude and time-dependence of the Doppler feedback mechanism in Very High Temperature reactors. This mechanism is the foremost contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic (TRISO) coated particles. Therefore, its correct prediction is essential to the conduct of safety analyses for these reactors. Since the effect is directly dependent on the actual temperature reached by the fuel during transients, the underlying phenomena of heat deposition, heat transfer and temperature rise must be correctly predicted. To achieve the above objective, this project will explore an approach that accounts for lattice effects as well as local temperature variations and the correct definition of temperature and related local effects.

  19. Ultrasonic intrusion sensor using the Doppler effect; Choonpa Doppler hoshiki shinnyu sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kani, H; Iwasaki, N; Goto, M [Nippon Soken, Inc., Tokyo (Japan); Tsuzuki, T; Nakamura, T [Denso Corp., Aichi (Japan)

    1997-10-01

    For vehicle anti-theft alarm systems which cope with vehicle and car component theft, EU initiated vehicle security regulations from Jan 1997. Also, the insurance industry has instituted the insurance certification of vehicle anti-theft alarm systems. We have developed an ultrasonic intrusion sensor using the doppler effect for vehicle anti-theft alarm systems specifically for these EU regulations and insurance certification. 2 refs., 7 figs., 1 tab.

  20. Laser Doppler flowmetry in endodontics: a review.

    Science.gov (United States)

    Jafarzadeh, H

    2009-06-01

    Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.

  1. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    Directory of Open Access Journals (Sweden)

    Anderson Chun On Tsang

    2015-04-01

    Full Text Available Purpose: The aim of this study was to validate a computational fluid dynamics (CFD simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents.

  2. Fast Transient And Spatially Non-Homogenous Accident Analysis Of Two-Dimensional Cylindrical Nuclear Reactor

    International Nuclear Information System (INIS)

    Yulianti, Yanti; Su'ud, Zaki; Waris, Abdul; Khotimah, S. N.; Shafii, M. Ali

    2010-01-01

    The research about fast transient and spatially non-homogenous nuclear reactor accident analysis of two-dimensional nuclear reactor has been done. This research is about prediction of reactor behavior is during accident. In the present study, space-time diffusion equation is solved by using direct methods which consider spatial factor in detail during nuclear reactor accident simulation. Set of equations that obtained from full implicit finite-difference discretization method is solved by using iterative methods ADI (Alternating Direct Implicit). The indication of accident is decreasing macroscopic absorption cross-section that results large external reactivity. The power reactor has a peak value before reactor has new balance condition. Changing of temperature reactor produce a negative Doppler feedback reactivity. The reactivity will reduce excess positive reactivity. Temperature reactor during accident is still in below fuel melting point which is in secure condition.

  3. Magnetic resonance imaging and three-dimensional ultrasound of carotid atherosclerosis: mapping regional differences.

    Science.gov (United States)

    Krasinski, Adam; Chiu, Bernard; Fenster, Aaron; Parraga, Grace

    2009-04-01

    To evaluate differences in carotid atherosclerosis measured using magnetic resonance imaging (MRI) and three-dimensional ultrasound (3DUS). Ten subject volunteers underwent carotid 3DUS and MRI (multislice black blood fast spin echo, T1-weighted contrast, double inversion recovery, 0.5 mm in-plane resolution, 2 mm slice, 3.0 T) within 1 hour. 3DUS and MR images were manually segmented by two observers providing vessel wall and lumen contours for quantification of vessel wall volume (VWV) and generation of carotid thickness maps. MRI VWV (1040 +/- 210 mm(3)) and 3DUS VWV (540 +/- 110 mm(3)) were significantly different (P Power Doppler US confirmed that heterogeneity in the common carotid artery in all patients resulted from apparent flow disturbances, not atherosclerotic plaque. MRI and 3DUS VWV were significantly different and carotid maps showed homogeneous thickness differences and heterogeneity in specific regions of interest identified as MR flow artifacts in the common carotid artery.

  4. New Approaches For Asteroid Spin State and Shape Modeling From Delay-Doppler Radar Images

    Science.gov (United States)

    Raissi, Chedy; Lamee, Mehdi; Mosiane, Olorato; Vassallo, Corinne; Busch, Michael W.; Greenberg, Adam; Benner, Lance A. M.; Naidu, Shantanu P.; Duong, Nicholas

    2016-10-01

    Delay-Doppler radar imaging is a powerful technique to characterize the trajectories, shapes, and spin states of near-Earth asteroids; and has yielded detailed models of dozens of objects. Reconstructing objects' shapes and spins from delay-Doppler data is a computationally intensive inversion problem. Since the 1990s, delay-Doppler data has been analyzed using the SHAPE software. SHAPE performs sequential single-parameter fitting, and requires considerable computer runtime and human intervention (Hudson 1993, Magri et al. 2007). Recently, multiple-parameter fitting algorithms have been shown to more efficiently invert delay-Doppler datasets (Greenberg & Margot 2015) - decreasing runtime while improving accuracy. However, extensive human oversight of the shape modeling process is still required. We have explored two new techniques to better automate delay-Doppler shape modeling: Bayesian optimization and a machine-learning neural network.One of the most time-intensive steps of the shape modeling process is to perform a grid search to constrain the target's spin state. We have implemented a Bayesian optimization routine that uses SHAPE to autonomously search the space of spin-state parameters. To test the efficacy of this technique, we compared it to results with human-guided SHAPE for asteroids 1992 UY4, 2000 RS11, and 2008 EV5. Bayesian optimization yielded similar spin state constraints within a factor of 3 less computer runtime.The shape modeling process could be further accelerated using a deep neural network to replace iterative fitting. We have implemented a neural network with a variational autoencoder (VAE), using a subset of known asteroid shapes and a large set of synthetic radar images as inputs to train the network. Conditioning the VAE in this manner allows the user to give the network a set of radar images and get a 3D shape model as an output. Additional development will be required to train a network to reliably render shapes from delay-Doppler

  5. Two-dimensional NMR spectrometry

    International Nuclear Information System (INIS)

    Farrar, T.C.

    1987-01-01

    This article is the second in a two-part series. In part one (ANALYTICAL CHEMISTRY, May 15) the authors discussed one-dimensional nuclear magnetic resonance (NMR) spectra and some relatively advanced nuclear spin gymnastics experiments that provide a capability for selective sensitivity enhancements. In this article and overview and some applications of two-dimensional NMR experiments are presented. These powerful experiments are important complements to the one-dimensional experiments. As in the more sophisticated one-dimensional experiments, the two-dimensional experiments involve three distinct time periods: a preparation period, t 0 ; an evolution period, t 1 ; and a detection period, t 2

  6. Detection and volume estimation of embolic air in the middle cerebral artery using transcranial Doppler sonography.

    Science.gov (United States)

    Bunegin, L; Wahl, D; Albin, M S

    1994-03-01

    Cerebral embolism has been implicated in the development of cognitive and neurological deficits following bypass surgery. This study proposes methodology for estimating cerebral air embolus volume using transcranial Doppler sonography. Transcranial Doppler audio signals of air bubbles in the middle cerebral artery obtained from in vivo experiments were subjected to a fast-Fourier transform analysis. Audio segments when no air was present as well as artifact resulting from electrocautery and sensor movement were also subjected to fast-Fourier transform analysis. Spectra were compared, and frequency and power differences were noted and used for development of audio band-pass filters for isolation of frequencies associated with air emboli. In a bench model of the middle cerebral artery circulation, repetitive injections of various air volumes between 0.5 and 500 microL were made. Transcranial Doppler audio output was band-pass filtered, acquired digitally, then subjected to a fast-Fourier transform power spectrum analysis and power spectrum integration. A linear least-squares correlation was performed on the data. Fast-Fourier transform analysis of audio segments indicated that frequencies between 250 and 500 Hz are consistently dominant in the spectrum when air emboli are present. Background frequencies appear to be below 240 Hz, and artifact resulting from sensor movement and electrocautery appears to be below 300 Hz. Data from the middle cerebral artery model filtered through a 307- to 450-Hz band-pass filter yielded a linear relation between emboli volume and the integrated value of the power spectrum near 40 microL. Detection of emboli less than 0.5 microL was inconsistent, and embolus volumes greater than 40 microL were indistinguishable from one another. The preliminary technique described in this study may represent a starting point from which automated detection and volume estimation of cerebral emboli might be approached.

  7. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  8. ACHIEVING CONSISTENT DOPPLER MEASUREMENTS FROM SDO /HMI VECTOR FIELD INVERSIONS

    International Nuclear Information System (INIS)

    Schuck, Peter W.; Antiochos, S. K.; Leka, K. D.; Barnes, Graham

    2016-01-01

    NASA’s Solar Dynamics Observatory is delivering vector magnetic field observations of the full solar disk with unprecedented temporal and spatial resolution; however, the satellite is in a highly inclined geosynchronous orbit. The relative spacecraft–Sun velocity varies by ±3 km s −1 over a day, which introduces major orbital artifacts in the Helioseismic Magnetic Imager (HMI) data. We demonstrate that the orbital artifacts contaminate all spatial and temporal scales in the data. We describe a newly developed three-stage procedure for mitigating these artifacts in the Doppler data obtained from the Milne–Eddington inversions in the HMI pipeline. The procedure ultimately uses 32 velocity-dependent coefficients to adjust 10 million pixels—a remarkably sparse correction model given the complexity of the orbital artifacts. This procedure was applied to full-disk images of AR 11084 to produce consistent Dopplergrams. The data adjustments reduce the power in the orbital artifacts by 31 dB. Furthermore, we analyze in detail the corrected images and show that our procedure greatly improves the temporal and spectral properties of the data without adding any new artifacts. We conclude that this new procedure makes a dramatic improvement in the consistency of the HMI data and in its usefulness for precision scientific studies.

  9. A three-dimensional pin-wise analysis for CEA ejection accident

    Energy Technology Data Exchange (ETDEWEB)

    Park, Guen-Tae; Park, Min-Ho; Park, Jin-Woo; Um, Kil-Sup; Choi, Tong-Soo [KEPCO NF, Daejeon (Korea, Republic of)

    2016-10-15

    The ejection of a control element assembly (CEA) with high reactivity worth causes the sudden insertion of reactivity into the core. Immediately after the CEA ejection, the nuclear power of the reactor dramatically increases in an exponential behavior until the doppler effect becomes important and turns the reactivity balance and power down to lower levels. The 3-D CEA ejection analysis methodology has been developed using the multi-dimensional code coupling system, CHASER, which couples three dimensional core neutron kinetics code ASTRA, subchannel analysis code THALES, and fuel performance analysis code FROST using message passing interface (MPI). This paper presents the pin-by-pin level analysis result with the 3-D CEA ejection analysis methodology using the CHASER. The pin-by-pin level analysis consists of DNBR, enthalpy and Pellet/Clad Mechanical Interaction (PCMI) analysis. All the evaluations are simulated for APR1400 plant loaded with PLUS7 fuel. In this paper, the pin-by-pin analysis using the multidimensional core transient code, CHASER, is presented with respect to enthalpy, DNBR and PCMI for APR1400 plant loaded with PLUS7 fuel. For the pin-by-pin enthalpy and DNBR analysis, the quarter core for HFP case or 15 - 20 assemblies around the most severe assembly for part powers or HZP cases are selected. And PCMI calculation is performed for all the rods in the whole core during a conservative time period. The pin-by-pin analysis results show that the regulatory guidelines of CEA ejection accident are satisfied.

  10. Real time 3D structural and Doppler OCT imaging on graphics processing units

    Science.gov (United States)

    Sylwestrzak, Marcin; Szlag, Daniel; Szkulmowski, Maciej; Gorczyńska, Iwona; Bukowska, Danuta; Wojtkowski, Maciej; Targowski, Piotr

    2013-03-01

    In this report the application of graphics processing unit (GPU) programming for real-time 3D Fourier domain Optical Coherence Tomography (FdOCT) imaging with implementation of Doppler algorithms for visualization of the flows in capillary vessels is presented. Generally, the time of the data processing of the FdOCT data on the main processor of the computer (CPU) constitute a main limitation for real-time imaging. Employing additional algorithms, such as Doppler OCT analysis, makes this processing even more time consuming. Lately developed GPUs, which offers a very high computational power, give a solution to this problem. Taking advantages of them for massively parallel data processing, allow for real-time imaging in FdOCT. The presented software for structural and Doppler OCT allow for the whole processing with visualization of 2D data consisting of 2000 A-scans generated from 2048 pixels spectra with frame rate about 120 fps. The 3D imaging in the same mode of the volume data build of 220 × 100 A-scans is performed at a rate of about 8 frames per second. In this paper a software architecture, organization of the threads and optimization applied is shown. For illustration the screen shots recorded during real time imaging of the phantom (homogeneous water solution of Intralipid in glass capillary) and the human eye in-vivo is presented.

  11. [Vascular complications following kidney transplant: the role of color-Doppler imaging].

    Science.gov (United States)

    Granata, Antonio; Floccari, Fulvio; Lentini, Paolo; Vittoria, Salvatore; Di Pietro, Fabio; Zamboli, Pasquale; Fiorini, Fulvio; Fatuzzo, Pasquale

    2012-01-01

    The progressive decline in the incidence of graft rejection has made urological, surgical, parenchymal and vascular complications of kidney transplant more frequent. The latter, although accounting for only 5-10% of all post-transplant complications, are a frequent cause of graft loss. Ultrasonography, both in B-mode and with Doppler ultrasound, is an important diagnostic tool in case of clinical conditions which might impair kidney function. Even though ultrasonography is considered fundamental in the diagnosis of parenchymal and surgical complications of the transplanted kidney, its role is not fully understood in case of vascular complications of the graft. The specificity of Doppler ultrasound is very important in case of stenosis of the transplanted renal artery, pseudoaneurysms, arteriovenous fistulas, and thrombosis with complete or partial artery or vein occlusion. Doppler and color determinations present high diagnostic accuracy, which is higher in case of successive measurements performed during the follow-up of the graft. Modern techniques including contrast-enhanced ultrasound increase the diagnostic power of ultrasonography in case of vascular complications of the transplanted kidney, planted kidney.

  12. SCANDI – an all-sky Doppler imager for studies of thermospheric spatial structure

    Directory of Open Access Journals (Sweden)

    A. L. Aruliah

    2010-02-01

    Full Text Available A new all-sky Fabry-Perot Interferometer called the Scanning Doppler Imager (SCANDI was built and installed at Longyearbyen in December 2006. Observations have been made of the Doppler shifts and Doppler broadening of the 630 nm airglow and aurora, from which upper thermospheric winds and temperatures are calculated. SCANDI allows measurements over a field-of-view (FOV with a horizontal radius of nearly 600 km for observations at an altitude of 250 km using a time resolution of 8 min. The instrument provides the ability to observe thermospheric spatial structure within a FOV which overlaps that of the EISCAT Svalbard radar and CUTLASS SuperDARN radars. Coordinating with these instruments provides an important opportunity for studying ion-neutral coupling. The all-sky image is divided into several sectors to provide a horizontal spatial resolution of between 100–300 km. This is a powerful extension in observational capability but requires careful calibration and data analysis, as described here. Two observation modes were used: a fixed and a scanning etalon gap. SCANDI results are corroborated using the Longyearbyen single look direction FPI, and ESR measurements of the ion temperatures. The data show thermospheric temperature gradients of a few Kelvins per kilometre, and a great deal of meso-scale variability on spatial scales of several tens of kilometres.

  13. Design And Analysis Of Doppler Radar-Based Vehicle Speed Detection

    Directory of Open Access Journals (Sweden)

    Su Myat Paing

    2015-08-01

    Full Text Available The most unwanted thing to happen to a road user is road accident. Most of the fatal accidents occur due to over speeding. Faster vehicles are more prone to accident than the slower one. Among the various methods for detecting speed of the vehicle object detection systems based on Radar have been replaced for about a century for various purposes like detection of aircrafts spacecraft ships navigation reading weather formations and terrain mapping. The essential feature in adaptive vehicle activated sign systems is the accurate measurement of a vehicles velocity. The velocities of the vehicles are acquired from a continuous wave Doppler radar. A very low amount of power is consumed in this system and only batteries can use to operate. The system works on the principle of Doppler Effect by detecting the Doppler shift in microwaves reflected from a moving object. Since the output of the sensor is sinusoidal wave with very small amplitude and needs to be amplified with the help of the amplifier before further processing. The purpose to calculate and display the speed on LCD is performed by the microcontroller.

  14. From a formal training program in musculoskeletal ultrasound (MSUS) to a high reproducibility for Doppler ultrasound in rheumatoid arthritis.

    Science.gov (United States)

    Villota, Orlando; Diaz, Mario; Ceron, Carmen; Moller, Ingrid; Naredo, Esperanza; Saaibi, Diego Luis

    2017-07-28

    To assess the intra- and inter-observer reliability of ultrasound (US) in scoring B-mode, Doppler synovitis and combined B-mode and Doppler synovitis scores in different peripheral joints of rheumatoid arthritis (RA) patients. Four rheumatologists with a formal training in musculoskeletal US (MSKUS) particularly focus on definitions and scoring synovitis on B-mode and Doppler mode participated in a patient-based reliability exercise on 16 active RA patients. The four rheumatologists independently and consecutively performed a B-mode and power Doppler (PD) US assessment of 7 joints of each patient in two rounds in a blinded fashion. Each joint was semi quantitatively scored from 0 to 3 for B-mode synovitis (BS), Doppler synovitis (DS), and combined B-mode/