WorldWideScience

Sample records for dimensional gel dosimetry

  1. Polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Baldock, C [Institute of Medical Physics, School of Physics, University of Sydney (Australia); De Deene, Y [Radiotherapy and Nuclear Medicine, Ghent University Hospital (Belgium); Doran, S [CRUK Clinical Magnetic Resonance Research Group, Institute of Cancer Research, Surrey (United Kingdom); Ibbott, G [Radiation Physics, UT M D Anderson Cancer Center, Houston, TX (United States); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, BC (Canada); Lepage, M [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et de radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, ON (Canada); Oldham, M [Department of Radiation Oncology, Duke University Medical Center, Durham, NC (United States); Schreiner, L J [Cancer Centre of South Eastern Ontario, Kingston, ON (Canada)], E-mail: c.baldock@physics.usyd.edu.au, E-mail: yves.dedeene@ugent.be

    2010-03-07

    Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented. (topical review)

  2. Applications of gel dosimetry

    International Nuclear Information System (INIS)

    Ibbott, Geoffrey S

    2004-01-01

    Gel dosimetry has been examined as a clinical dosimeter since the 1950s. During the last two decades, however, a rapid increase in the number of investigators has been seen, and the body of knowledge regarding gel dosimetry has expanded considerably. Gel dosimetry is still considered a research project, and the introduction of this tool into clinical use is proceeding slowly. This paper will review the characteristics of gel dosimetry that make it desirable for clinical use, the postulated and demonstrated applications of gel dosimetry, and some complications, set-backs, and failures that have contributed to the slow introduction into routine clinical use

  3. A Practical Use for FXG Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Olding, T; Salomons, G; Darko, J; Schreiner, L J, E-mail: Tim.Olding@krcc.on.c

    2010-11-01

    In-phantom Fricke-xylenol orange-gelatin (FXG) gel dosimetry yields three dimensional (3D) dose data for intensity modulated radiation therapy (IMRT) treatment plan verification within 18-24 hours from the point of request. The information obtained from a 3% dose difference, 3 mm distance-to-agreement gamma function comparison between treatment plan dose and gel-measured dose then provides a useful secondary 3D quality assurance check of the treatment plan prior to delivery.

  4. NMR mechanisms in gel dosimetry

    International Nuclear Information System (INIS)

    Schreiner, L J

    2009-01-01

    Nuclear magnetic resonance was critical to the development of gel dosimetry, as it established the potential for three dimensional dosimetry with chemical dosimeter systems through magnetic resonance imaging [1]. In the last two decades MRI has served as the gold standard for imaging, while NMR relaxometry has played an important role in the development and understanding of the behaviour of new gel dosimetry systems. Therefore, an appreciation of the relaxation mechanisms determining the NMR behaviour of irradiated gel dosimeters is important for a full comprehension of a considerable component of the literature on gel dosimetry. A number of excellent papers have presented this important theory, this brief review will highlight some of the salient points made previously [1-5]. The spin relaxation of gel dosimeters (which determines the dose dependence in most conventional MR imaging) is determined principally by the protons on water molecules in the system. These water protons exist in different environments, or groups (see Figure 1): on bulk water, on water hydrating the chemical species that are being modified under irradiation, and on water hydrating the gel matrix used to spatially stabilize the dosimeter (e.g., gelatin, agarose, etc). The spin relaxation depends on the inherent relaxation rate of each spin group, that is, on the relaxation rate which would be observed for the specific group if it were isolated. Also, the different water environments are not isolated from each other, and the observed relaxation rate also depends on the rate of exchange of magnetization between the groups, and on the fraction of protons in each group. In fact, the water exchanges quickly between the environments, so that relaxation is in what is usually termed the fast exchange regime. In the limit of fast exchange, the relaxation of the water protons is well characterized by a single exponential and hence by a single apparent relaxation rate. In irradiated gel dosimeters this

  5. 3D MR gel dosimetry with lung equivalent gel

    International Nuclear Information System (INIS)

    Scherer, J.; Solleder, M.; Schiessl, I.; Bogner, L.; Herbst, M.

    1998-01-01

    The MR gel dosimetry is used to verify complex 3D treatment plans. Till now this method served only for dose evaluation in homogeneous phantoms. On the way to build a heterogeneous anthropomorphic gel phantom, a lung equivalent gel with the density 0.4 g/cm 3 was developed. First experiments show a 1.55 times higher dose reponse in the low density gel (LD gel). The comparison of a dose distribution in a gel/LD gel/gel slab phantom with Monte Carlo calculations shows good agreement within 5%. More over the accuray of the measuring device magnetic resonance imager was studied in respect to the now exclusive digital image processing with the software MRD (MR dosimetry). Because of the dimensions of the Fricke gel phantom an artefact correction, based on the data from the unirradiated phantom proved to be essential. (orig.) [de

  6. Dosimetry using radiosensitive gels in radiotherapy: significance and methods

    International Nuclear Information System (INIS)

    Gibon, D.; Bourel, P.; Castelain, B.; Marchandise, X.; Rousseau, J.

    2001-01-01

    The goal of conformal radiotherapy is to concentrate the dose in a well-defined volume by avoiding the neighbouring healthy structures. This technique requires powerful treatment planning software and a rigorous control of estimated dosimetry. The usual dosimetric tools are not adapted to visualize and validate complex 3D treatment. Dosimetry by radiosensitive gel permits visualization and measurement of the three-dimensional dose distribution. The objective of this work is to report on current work in this field and, based on our results and our experience, to draw prospects for an optimal use of this technique. Further developments will relate to the realization of new radiosensitive gels satisfying, as well as possible, cost requirements, easy realization and use, magnetic resonance imagery (MRI) sensitivity, tissue equivalence, and stability. Other developments focus on scanning methods, especially in MRI to measure T1 and T2. (author)

  7. Implementation of MRI gel dosimetry in radiation therapy

    International Nuclear Information System (INIS)

    Baeck, S.Aa.J.

    1998-12-01

    Gel dosimetry was used together with magnetic resonance imaging (MRI) to measure three-dimensional absorbed dose distributions in radiation therapy. Two different dosimeters were studied: ferrous- and monomer gel, based on the principles of radiation-induced oxidation and polymerisation, respectively. Single clinical electron and photon beams were evaluated and gel dose distributions were mainly within 2% of conventional detector results. The ferrous-gel was also used for clinical proton beams. A decrease in signal per absorbed dose was found close to the end of the range of the protons (15-20%). This effect was explained as a linear energy transfer dependence, further supported with Monte Carlo simulations. A method for analysing and comparing data from treatment planning system (TPS) and gel measurements was developed. The method enables a new pixel by pixel evaluation, isodose comparison and dose volume histogram verification. Two standard clinical radiation therapy procedures were examined using the developed TPS verification method. The treatment regimes included several beams of different radiation qualities. The TPS calculated data were in very good agreement with the dose distribution measured by the ferrous-gel. However, in a beam abutment region, larger dose difference was found. Beam adjustment errors and a minor TPS underestimation of the lateral scatter contribution outside the primary electron beam may explain the discrepancy. The overall uncertainty in the ferrous-gel dose determination was considerably reduced using an optimised MRI acquisition protocol and a new MRI scanner. The relative dose uncertainty was found to be better than 3.3% for all dose levels (95% confidence level). Using the method developed for comparing measured gel data with calculated treatment plans, the gel dosimetry method was proven to be a useful tool for radiation treatment planning verification

  8. Implementation of MRI gel dosimetry in radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Baeck, S.Aa.J

    1998-12-01

    Gel dosimetry was used together with magnetic resonance imaging (MRI) to measure three-dimensional absorbed dose distributions in radiation therapy. Two different dosimeters were studied: ferrous- and monomer gel, based on the principles of radiation-induced oxidation and polymerisation, respectively. Single clinical electron and photon beams were evaluated and gel dose distributions were mainly within 2% of conventional detector results. The ferrous-gel was also used for clinical proton beams. A decrease in signal per absorbed dose was found close to the end of the range of the protons (15-20%). This effect was explained as a linear energy transfer dependence, further supported with Monte Carlo simulations. A method for analysing and comparing data from treatment planning system (TPS) and gel measurements was developed. The method enables a new pixel by pixel evaluation, isodose comparison and dose volume histogram verification. Two standard clinical radiation therapy procedures were examined using the developed TPS verification method. The treatment regimes included several beams of different radiation qualities. The TPS calculated data were in very good agreement with the dose distribution measured by the ferrous-gel. However, in a beam abutment region, larger dose difference was found. Beam adjustment errors and a minor TPS underestimation of the lateral scatter contribution outside the primary electron beam may explain the discrepancy. The overall uncertainty in the ferrous-gel dose determination was considerably reduced using an optimised MRI acquisition protocol and a new MRI scanner. The relative dose uncertainty was found to be better than 3.3% for all dose levels (95% confidence level). Using the method developed for comparing measured gel data with calculated treatment plans, the gel dosimetry method was proven to be a useful tool for radiation treatment planning verification 103 refs, 20 figs, 6 tabs

  9. Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry

    International Nuclear Information System (INIS)

    Jirasek, A; Hilts, M; McAuley, K B

    2010-01-01

    A primary limitation of current x-ray CT polymer gel dosimetry is the low contrast, and hence poor dose resolution, of dose images produced by the system. The low contrast is largely due to the low-dose sensitivity of current formulations of polymer gel for x-ray CT imaging. This study reports on the investigation of new dosimeter formulations with improved dose sensitivity for x-ray CT polymer gel dosimetry. We incorporate an isopropanol co-solvent into an N-isopropylacrylamide-based gel formulation in order to increase the total monomer/crosslinker concentration (%T) within the formulation. It is shown that gels of high %T exhibit enhanced dose sensitivity and dose resolutions over traditional formulations. The gels are shown to be temporally stable and reproducible. A single formulation (16%T) is used to demonstrate the capabilities of the x-ray CT polymer gel dosimetry system in measuring known dose distributions. A 1 L gel volume is exposed to three separate irradiations: a single-field percent depth dose, a two-field 'cross' and a three-field 'test case'. The first two irradiations are used to generate a dose calibration curve by which images are calibrated. The calibrated images are compared with treatment planning predictions and it is shown that the x-ray CT polymer gel dosimetry system is capable of capturing spatial and dose information accurately. The proposed new gel formulation is shown to be sensitive, stable and to improve the dose resolution over current formulations so as to provide a feasible gel for clinical applications of x-ray CT polymer gel dosimetry.

  10. Polymer gel dosimeters with enhanced sensitivity for use in x-ray CT polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria BC V8W 3P6 (Canada); Hilts, M [Medical Physics, BC Cancer Agency-Vancouver Island Centre, Victoria BC V6R 2B6 (Canada); McAuley, K B, E-mail: jirasek@uvic.c [Department of Chemical Engineering, Queens University, Kingston, ON K7 L 3N6 (Canada)

    2010-09-21

    A primary limitation of current x-ray CT polymer gel dosimetry is the low contrast, and hence poor dose resolution, of dose images produced by the system. The low contrast is largely due to the low-dose sensitivity of current formulations of polymer gel for x-ray CT imaging. This study reports on the investigation of new dosimeter formulations with improved dose sensitivity for x-ray CT polymer gel dosimetry. We incorporate an isopropanol co-solvent into an N-isopropylacrylamide-based gel formulation in order to increase the total monomer/crosslinker concentration (%T) within the formulation. It is shown that gels of high %T exhibit enhanced dose sensitivity and dose resolutions over traditional formulations. The gels are shown to be temporally stable and reproducible. A single formulation (16%T) is used to demonstrate the capabilities of the x-ray CT polymer gel dosimetry system in measuring known dose distributions. A 1 L gel volume is exposed to three separate irradiations: a single-field percent depth dose, a two-field 'cross' and a three-field 'test case'. The first two irradiations are used to generate a dose calibration curve by which images are calibrated. The calibrated images are compared with treatment planning predictions and it is shown that the x-ray CT polymer gel dosimetry system is capable of capturing spatial and dose information accurately. The proposed new gel formulation is shown to be sensitive, stable and to improve the dose resolution over current formulations so as to provide a feasible gel for clinical applications of x-ray CT polymer gel dosimetry.

  11. Dose response study of PVA-Fx gel for three dimensional dose distribution

    International Nuclear Information System (INIS)

    Brindha, S.; Ayyangar, Komanduri M.; Shen, Bin; Saw, Cheng B.

    2001-01-01

    Modern radiotherapy techniques involve complex field arrangements using conformal and intensity modulated radiation that requires three dimensional treatment planning. The verification of these plans poses even more challenge. In 1984, Gore et al., proposed that ferrous gel dosimeters combined with magnetic resonance imaging (MRI) could be used to measure three dimensional radiation dose distributions. Since then, there has been much interest in the development of gel dosimetry to aid the determination of three dimensional dose distributions during field arrangements. In this work, preparation and study of the MR characteristics of a PVA-Fx gel reported in the literature is presented

  12. Radiotherapy gel dosimetry

    International Nuclear Information System (INIS)

    Baldock, C.

    2002-01-01

    shapes and sizes while sparing normal tissue. The situation is further complicated if the normal tissues are critical organs or are particularly sensitive to radiation. Radiotherapy techniques employed to obtain a closer conformation of the dose distribution to the tumour volume are referred to as conformal radiotherapy techniques. The clinical implementation of conformal therapy has been delayed by limitations in the verification of conformal dose distributions calculated by treatment planning systems prior to the irradiation of the patient and the verification of complex treatments during its delivery to the patient. There are several aspects of conformal therapy that complicate dose verification. To achieve the dose distributions conforming to complex 3D volumes, high dose gradients arise in the treatment volume. Further, overdose or underdose regions can exist when separate radiation fields are used to deliver additional radiation. These aspects require that practical dose measurement (dosimetry) techniques be able to integrate dose over time and easily measure dose distributions in 3D with high spatial resolution. Traditional dosimeters, such as ion chambers, thermoluminescent dosimeters and radiographic film do not fulfil these requirements. Novel gel dosimetry techniques are being developed in which dose distributions can potentially be determined in vitro in 3D using anthropomorphic phantoms to simulate a clinically irradiated situation. As long ago as the 1950's, radiation-induced colour change in dyes was used to investigate radiation doses in gels. It was subsequently shown that radiation induced changes in nuclear magnetic resonance (NMR) relaxation properties of gels infused with conventional Fricke dosimetry solutions could be measured using magnetic resonance imaging (MRI). In Fricke gels, Fe 2+ ions in ferrous sulphate solutions are usually dispersed throughout a gelatin, agarose or PVA matrix. Radiation-induced changes in the dosimeters are considered to

  13. Recent developments in polymer gel dosimetry

    International Nuclear Information System (INIS)

    John Schreiner, L.; Olding, Tim; Holmes, Oliver; McAuley, Kim

    2008-01-01

    Modern radiation therapy particularly with intensity modulation techniques (IMRT) offers the potential to improve patient outcomes by better limiting high doses to the tumour alone. In this presentation we report our progress in developing gel dosimetry with new less toxic dosimeters using a fast commercial optical computed tomography (OCT) scanner. We will demonstrate that these adjustments in the approach to gel dosimetry help facilitate its introduction into clinical use. We will review practical advances in system quality assurance and scatter correction to improve optical CT quantification, and show an example of a clinical implementation of an IGRT treatment validation

  14. The spatial resolution in dosimetry with normoxic polymer-gels investigated with the dose modulation transfer approach

    International Nuclear Information System (INIS)

    Bayreder, Christian; Schoen, Robert; Wieland, M.; Georg, Dietmar; Moser, Ewald; Berg, Andreas

    2008-01-01

    The verification of dose distributions with high dose gradients as appearing in brachytherapy or stereotactic radiotherapy for example, calls for dosimetric methods with sufficiently high spatial resolution. Polymer gels in combination with a MR or optical scanner as a readout device have the potential of performing the verification of a three-dimensional dose distribution within a single measurement. The purpose of this work is to investigate the spatial resolution achievable in MR-based polymer gel dosimetry. The authors show that dosimetry on a very small spatial scale (voxel size: 94x94x1000 μm 3 ) can be performed with normoxic polymer gels using parameter selective T2 imaging. In order to prove the spatial resolution obtained we are relying on the dose-modulation transfer function (DMTF) concept based on very fine dose modulations at half periods of 200 μm. Very fine periodic dose modulations of a 60 Co photon field were achieved by means of an absorption grid made of tungsten-carbide, specifically designed for quality control. The dose modulation in the polymer gel is compared with that of film dosimetry in one plane via the DMTF concept for general access to the spatial resolution of a dose imaging system. Additionally Monte Carlo simulations were performed and used for the calculation of the DMTF of both, the polymer gel and film dosimetry. The results obtained by film dosimetry agree well with those of Monte Carlo simulations, whereas polymer gel dosimetry overestimates the amplitude value of the fine dose modulations. The authors discuss possible reasons. The in-plane resolution achieved in this work competes with the spatial resolution of standard clinical film-scanner systems

  15. Gel dosimetry for conformal radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G [Department of Physics of the University and INFN, Milan (Italy)

    2005-07-01

    With the continuum development of conformal radio therapies, aimed at delivering high dose to tumor tissue and low dose to the healthy tissue around, the necessities has appeared of suitable improvement of dosimetry techniques giving the possibility of obtaining dose images to be compared with diagnostic images. Also if wide software has been developed for calculating dose distributions in the fields of various radiotherapy units, experimental verifications are necessary, in particular in the case of complex geometries in conformal radiotherapy. Gel dosimetry is a promising method for imaging the absorbed dose in tissue-equivalent phantoms, with the possibility of 3D reconstruction of the spatial dose distribution, with milli metric resolution. Optical imaging of gel dosimeters, based on visible light absorbance analysis, has shown to be a reliable technique for achieving dose distributions. (Author)

  16. MO-B-BRB-00: Three Dimensional Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  17. Dosimetry Evolution in Teletherapy: Polimer Gel

    Science.gov (United States)

    Hamann, J. H.; Peixoto, J. G. P.

    2018-03-01

    Polymer gels evolution and chemical composition used in dosimetry. Type Composition First gels Folin’s Phenol or Gallic Acid Polymer Gel Agarose and N,N’-methylene-bis-acrylamide BANANA Bis, acrylamide, nitrous oxide and agarose BANG-1TM Bis, acrylamide, nitrogen and gelatin BANG-2TM Bis, acrylic acid, sodium hydroxide, nitrogen and gelatin BANG-3TM Bis, methacrylate acid, sodium hydroxide, nitrogen and gelatin MAGIC Methacrylate acid, ascorbic acid, gelatin and copper sulphate

  18. Three dimensional gel dosimetry by use of nuclear magnetic resonance imaging (MRI)

    Energy Technology Data Exchange (ETDEWEB)

    De Deene, Y; De Wagter, C; Van Duyse, B; Achten, E; De Neve, W [Ghent Rijksuniversiteit (Belgium). Kliniek voor Radiotherapie en Kerngeneeskunde; De Poorter, J [Ghent Univ. (Belgium). Dept. of Magnetic Resonance

    1995-12-01

    As co-monomers are found to polymerize by radiation, they are eligible for constructing a three dimensional dosimeter. Another kind of three dimensional dosimeter, based on the radiation sensitivity of the ferrous ions in a Fricke solution, was tested in a previous study. However, a major problem that occurs in this kind of gel dosimeters is the diffusion of the ferric and ferrous ions. The co-monomer gels are more stable. The degree of polymerisation is visualized with a clinical MRI system. Acrylamide and N,N-methylene-bis-acrylamide are dissolved in a gel composed of gelatin and water. By irradiation the co-monomers are polymerized to polyacrylamide. The gel is casted in humanoid forms. As such, a simulation of the irradiation of the patient can be performed. Magnetic resonance relaxivity images of the irradiated gel display the irradiation dose. The images of the gel are fused with the radiological images of the patient. Quantitation of the dose response of the co-monomer gel is obtained through calibration by test tubes.

  19. Three dimensional gel dosimetry by use of nuclear magnetic resonance imaging (MRI)

    International Nuclear Information System (INIS)

    De Deene, Y.; De Wagter, C.; Van Duyse, B.; Achten, E.; De Neve, W.; De Poorter, J.

    1995-01-01

    As co-monomers are found to polymerize by radiation, they are eligible for constructing a three dimensional dosimeter. Another kind of three dimensional dosimeter, based on the radiation sensitivity of the ferrous ions in a Fricke solution, was tested in a previous study. However, a major problem that occurs in this kind of gel dosimeters is the diffusion of the ferric and ferrous ions. The co-monomer gels are more stable. The degree of polymerisation is visualized with a clinical MRI system. Acrylamide and N,N-methylene-bis-acrylamide are dissolved in a gel composed of gelatin and water. By irradiation the co-monomers are polymerized to polyacrylamide. The gel is casted in humanoid forms. As such, a simulation of the irradiation of the patient can be performed. Magnetic resonance relaxivity images of the irradiated gel display the irradiation dose. The images of the gel are fused with the radiological images of the patient. Quantitation of the dose response of the co-monomer gel is obtained through calibration by test tubes

  20. Use of Magic polymer gels for dosimetry of unsealed source of yttrium 90

    International Nuclear Information System (INIS)

    Meynard, K.; Bordage, M.C.; Cassol, E.; Courbon, F.; Ravel, P.

    2007-01-01

    Polymer gels are relative chemical dosimeters. They allow to access to three-dimensional dose distribution. The aim of this study has been to investigate the preparation and the use of a polymer gel with a tissue equivalent density known as MAGIC gel from magnetic resonance imaging and x-ray computed tomography for non-sealed source dosimetry. This kind of gel is 'normoxic' because it can be manufactured and used in normal room atmosphere. In the first part of this study, its accuracy and sensibility were studied using external beam irradiation by photons. Spin-spin relaxation rate (R 2 ) and Computed Tomography (CT) number had been used to record gel responses. Using the same manufacture process. radiolabelled gels composed of 95% MAGIC gel and 5% of 90 Y termed 90 Y-MAGIC 95 with varying activity ranged from 0 to 30 MBq were made. In case of photon external beam irradiation, a linear response is observed whatever the calibration method and the imaging system used (the correlation coefficient r 2 > 0.98 in all cases). 90 Y-MAGIC 95 radiolabelled gel responses were recorded after 28. 76 and 124 h. The R 2 /dose curves are not linear: three phases can be described. the first being linear with a slow slope (0.14 s -1 Gy -1 instead of 0.41 s -1 Gy -1 for external beam irradiation of the same gel batch). This study shows safety of radiolabelled MAGIC gels manufacturing process and their large dosimetric feasibility. 90 Y-MAGIC 95 gel response appears to be reproducible and related to the absorbed dose, thus this gel is a promising tool for non-sealed source dosimetry. (authors)

  1. Introduction of a deformable x-ray CT polymer gel dosimetry system

    Science.gov (United States)

    Maynard, E.; Heath, E.; Hilts, M.; Jirasek, A.

    2018-04-01

    This study introduces the first 3D deformable dosimetry system based on x-ray computed tomography (CT) polymer gel dosimetry and establishes the setup reproducibility, deformation characteristics and dose response of the system. A N-isopropylacrylamide (NIPAM)-based gel formulation optimized for x-ray CT gel dosimetry was used, with a latex balloon serving as the deformable container and low-density polyethylene and polyvinyl alcohol providing additional oxygen barrier. Deformable gels were irradiated with a 6 MV calibration pattern to determine dosimetric response and a dosimetrically uniform plan to determine the spatial uniformity of the response. Wax beads were added to each gel as fiducial markers to track the deformation and setup of the gel dosimeters. From positions of the beads on CT images the setup reproducibility and the limits and reproducibility of gel deformation were determined. Comparison of gel measurements with Monte Carlo dose calculations found excellent dosimetric accuracy, comparable to that of an established non-deformable dosimetry system, with a mean dose discrepancy of 1.5% in the low-dose gradient region and a gamma pass rate of 97.9% using a 3%/3 mm criterion. The deformable dosimeter also showed good overall spatial dose uniformity throughout the dosimeter with some discrepancies within 20 mm of the edge of the container. Tracking of the beads within the dosimeter found that sub-millimetre setup accuracy is achievable with this system. The dosimeter was able to deform and relax when externally compressed by up to 30 mm without sustaining any permanent damage. Internal deformations in 3D produced average marker movements of up to 12 mm along the direction of compression. These deformations were also shown to be reproducible over 100 consecutive deformations. This work has established several important characteristics of a new deformable dosimetry system which shows promise for future clinical applications, including the

  2. Experimental 3D dosimetry around a high-dose-rate clinical 192Ir source using a polyacrylamide gel (PAG) dosimeter

    International Nuclear Information System (INIS)

    McJury, M.; Tapper, P.D.; Griffin, S.; Cosgrove, V.P.; Webb, S.; Murphy, P.S.; Leach, M.O.; Oldham, M.

    1999-01-01

    It is well known that the experimental dosimetry of brachytherapy sources presents a challenge. Depending on the particular dosimeter used, measurements can suffer from poor spatial resolution (ion chambers), lack of 3D information (film) or errors due to the presence of the dosimeter itself distorting the radiation flux. To avoid these problems, we have investigated the dosimetry of a clinical 192 Ir source using a polyacrylamide gel (PAG) dosimeter. Experimental measurements of dose versus radial distance from the centre of the source (cross-line plots) were compared with calculations produced with a Nucletron NPS planning system. Good agreement was found between the planning system and gel measurements in planes selected for analysis. Gel dosimeter measurements in a coronal plane through the phantom showed a mean difference between measured absorbed dose and calculated dose of 0.17 Gy with SD=0.13Gy. Spatially, the errors at the reference point remain within one image pixel (1.0 mm). The use of polymer gel dosimetry shows promise for brachytherapy applications, offering complete, three-dimensional dose information, good spatial resolution and small measurement errors. Measurements close to the source, however, are difficult, due to some of the limiting properties of the polyacrylamide gel. (author)

  3. Gel Dosimetry Analysis of Gold Nanoparticle Application in Kilovoltage Radiation Therapy

    International Nuclear Information System (INIS)

    Marques, T; Schwarcke, M; Garrido, C; Zucolot, V; Baffa, O; Nicolucci, P

    2010-01-01

    In this work gold nanoparticles (AuNP) were embedded in MAGIC-f gel and irradiated in a 250 kV x-ray clinical beam. The signal of non-irradiated gel samples containing AuNPs showed maximum difference of 0.5% related to gel without nanoparticles. Different AuNPs concentrations were studied: 0.10 mM, 0.05 mM and 0.02 mM, presenting dose enhancements of 106%, 90% and 77% respectively. Monte Carlo spectrometry was performed to quantify theoretical changes in photon energy spectrums due to AuNPs presence. Concordance between simulated dose enhancements and gel dosimetry measurements was better than 97% to all concentrations studied. This study evidences that polymer gel dosimetry as a suitable tool to perform dosimetric investigations of nanoparticle applications in Radiation Therapy.

  4. Feasibility of quantitative PET/CT dosimetry for proton therapy using polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Zeidan, O A; Hsi, W C; Lopatiuk-Tirpak, O; Sriprisan, S I; Meeks, S L; Kupelian, P A; Li, Z; Palta, J R, E-mail: lenatirpak@gmail.co

    2010-11-01

    A feasibility study of proton beam PET/CT off-line quantitative dosimetry using polymer gels is presented. A newly developed proton-sensitive polymer gel dosimeter (BANG( (registered)) 3-Pro2) is used as a dosimeter and a tissue-equivalent phantom medium for this study. We explore a new approach to correlating measured proton 3-dimensional (3D) dose distributions directly to measured positron emission from in the gel medium using PET/CT imaging. A large cylindrical volume (2.2 Litres) of the gel was irradiated with a clinical modulated proton beam using irregular-shaped aperture geometry. The gel was imaged in a nearby PET/CT unit immediately (<3 min) after irradiation. Dose distribution in the gel was generated using an optical tomography scanning system. Direct 3D spatial comparison of dose and positron emission distributions was then performed. Profiles along the beam path show that the distal fall-off of the dose is nearly 2 cm deeper than the activity profile which is comparable to previous studies with plastic phantoms and Monte Carlo simulations of activity distributions. Planar PET and dose distributions at depth and perpendicular to beam axis show a strong one-to-one spatial correlation. This phantom study demonstrates that the gel medium could be potentially useful for quantifying various physical factors that can influence the PET activity range verification method in patients.

  5. Further developments and applications of layer gel dosimetry

    International Nuclear Information System (INIS)

    Gambarini, G; Carrara, M; Colli, V; Gay, S; Tomatis, S

    2004-01-01

    The method used to perform dosimetry with Fricke-xylenol orange-infused gels in form of layers remains the most reliable method for in-phantom dose profiling and imaging in high fluxes of thermal and epithermal neutrons. Gel-dosimeters in form of layers really give the possibility not only of obtaining spatial dose distributions but also of achieving measurements of each dose contribution in neutron fields. These advantages arise from the layer-geometry thanks to which neutron transport is not sensibly altered, even if the elemental gel composition is changed adding particular isotopes (for example 10 B), as necessary to perform the separation of dose contributions. The gel matrix composition and the experimental procedures, adopted for both dosimeter preparation and analysis, have been already described in previous works. In the present work, the improvements of the method employed for gel analysis, dose imaging and gel applications are illustrated

  6. Monte Carlo verification of polymer gel dosimetry applied to radionuclide therapy: a phantom study

    International Nuclear Information System (INIS)

    Gear, J I; Partridge, M; Flux, G D; Charles-Edwards, E

    2011-01-01

    This study evaluates the dosimetric performance of the polymer gel dosimeter 'Methacrylic and Ascorbic acid in Gelatin, initiated by Copper' and its suitability for quality assurance and analysis of I-131-targeted radionuclide therapy dosimetry. Four batches of gel were manufactured in-house and sets of calibration vials and phantoms were created containing different concentrations of I-131-doped gel. Multiple dose measurements were made up to 700 h post preparation and compared to equivalent Monte Carlo simulations. In addition to uniformly filled phantoms the cross-dose distribution from a hot insert to a surrounding phantom was measured. In this example comparisons were made with both Monte Carlo and a clinical scintigraphic dosimetry method. Dose-response curves generated from the calibration data followed a sigmoid function. The gels appeared to be stable over many weeks of internal irradiation with a delay in gel response observed at 29 h post preparation. This was attributed to chemical inhibitors and slow reaction rates of long-chain radical species. For this reason, phantom measurements were only made after 190 h of irradiation. For uniformly filled phantoms of I-131 the accuracy of dose measurements agreed to within 10% when compared to Monte Carlo simulations. A radial cross-dose distribution measured using the gel dosimeter compared well to that calculated with Monte Carlo. Small inhomogeneities were observed in the dosimeter attributed to non-uniform mixing of monomer during preparation. However, they were not detrimental to this study where the quantitative accuracy and spatial resolution of polymer gel dosimetry were far superior to that calculated using scintigraphy. The difference between Monte Carlo and gel measurements was of the order of a few cGy, whilst with the scintigraphic method differences of up to 8 Gy were observed. A manipulation technique is also presented which allows 3D scintigraphic dosimetry measurements to be compared to polymer

  7. Dosimetry for computed tomography using Fricke gel dosimetry and magnetic resonance imaging; Dosimetria em tomografia computadorizada empregando dosimetro Fricke gel e a tecnica de imageamento por ressonancia magnetica

    Energy Technology Data Exchange (ETDEWEB)

    Capeleti, Felipe Favaro; Campos, Leticia L., E-mail: felipe@gmpbrasil.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-04-15

    In this work it was determined a new method for the determination of absorbed doses in Computed Tomography (CT) examinations using Fricke gel dosimetry developed at IPEN. Absorbed doses were determined by different methods of analysis, such as optical absorption spectrometry, ionization chambers and magnetic resonance imaging. Lower limit of sensitivity of the Fricke gel solution, the solution repeatability signal Fricke gel and CT equipment, detection sensitivity, among other tests were performed. Different equipment of computed tomography with multiple detectors were used. The Fricke gel solution showed better repeatability than ±5.5% using the technique of optical absorption spectrophotometry and computed tomography equipment showed repeatability better than ±0.2%. The Fricke gel solution features an easy and relatively quick preparation, but it is necessary to be careful not to contaminate and lose the solution. With the results, it was confirmed the application of this type of dosimetry for computed tomography equipment. (author)

  8. Investigation of the Spatial Resolution of MR-Based Polymer Gel Dosimetry versus Film Densitometry using Dose Modulation Transfer Function

    Directory of Open Access Journals (Sweden)

    Reza Moghadam-Drodkhani

    2011-03-01

    Full Text Available Introduction: The conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. Although the polymer gel dosimetry method based on magnetic resonance imaging (MRI could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. Therefore, in this study, the spatial resolution of two systems of film densitometry and polymer gel dosimetry based on MRI has been evaluated by using the dose modulation transfer function (DMTF.   Material and Methods: Kodak therapy verification films and MAGICA polymer gel samples were positioned below a brass absorption grid with different periodic slices (a/2= 280, 525, 1125 μm, which was placed in a water bath container to avoid regions of dose build-up just below the absorption grid and then irradiated with Cobalt-60 photons on a Theratron external-beam treatment unit. Dose variation under the brass grid was determined using a calibration curve, while transverse relaxation time (T2 as the selective parameter in a dose image based on multiple echo MRI with 1.5 Tesla GE Signa Echo Speed system (FOV=10 cm, matrix size=512 ×512, pixel size =0.199×0.199 mm2, TE = 20, 40, 60, 80 ms, TR=4200 ms, NEX = 4, slice thickness=2 mm, gap=1 mm was calculated. DMTF from the modulation depths of T2 and variation in film optical density after calibration would be achieved. The results of polymer gel were compared with film. Results: After deriving the dose distribution profile under the absorption grid, minima and maxima at the smallest period of a = 560 μm could scarcely be resolved, but the modulations due to a=2250 μm and a = 1050 μm grids could be discerned. The modulation depth for a=2250 μm grid was set to 100% and the other modulations were subsequently referred to this maximum modulation. For film densitometry at a = 1050 μm, the modulation depth was

  9. Magnetic Resonance Imaging Dosimetry application to chemical ferrous gels

    International Nuclear Information System (INIS)

    Calmet, Ch.

    2000-10-01

    MRI dosimetry is based on the determination of relaxation parameters (T1, T2). Chemical detectors whose NMR properties are sensitive to irradiation are used. Difficulties in absolute relaxation times measure limit the use of this technique. The aim of this work first consists in the development of a quantitative method to determine T, relaxation time on irradiated ferrous gels. So, we can study processes and parameters which affect the technique sensibility. The method sensitivity first depends on imaging instrumentation. Quantitative MRI method used is able to eliminate variable imager factors. The study of instrumental parameters (coil, sequence parameters) permits to define an imaging protocol which is a function of the considered application (volume size, spatial resolution and accuracy). The method sensitivity depends on the detector sensibility too. The best composition of ferrous gel has been determined. Dose distributions are obtained in three minutes. Comparison between MRI results and conventional dosimetry methods (specially ionisation chamber and films) shows a deviation of about 5% for single irradiation with energy fields in the range of 300 keV to 25 MeV. So, the proposed method forms a suitable technique for 3D dosimetry. (author)

  10. Stereotactic radiosurgery photon field profile dosimetry using conventional dosimeters and polymer gel dosimetry. Analysis and inter-comparison

    Energy Technology Data Exchange (ETDEWEB)

    Pappas, E; Maris, T G; Zacharopoulou, F; Papadakis, A [Department of Medical Physics, Faculty of Medicine, University of Crete, 711 10 Stavrakia-Heraklion, Crete (Greece); Manolopoulos, S; Green, S [Queen Elizabeth Medical Centre, University Hospital Birmingham NHS Trust, Birmingham B15 2TH (United Kingdom); Wojnecki, C, E-mail: epappas@edu.med.uoc.gr

    2009-05-01

    Small photon fields are increasingly used in modern radiotherapy and especially in IMRT and SRS/SRT treatments. Accurate beam profile measurements of such beams are crucial for a precise and effective treatment. In this work four different dosimetric methods have been used for profile measurements of three small 6 MV circular fields having diameters of 7.5, 15.0 and 30.0 mm. A small sensitive volume air ion chamber, a diamond detector, a novel silicon-diode array and Vinyl-Pyrrolidone based polymer gel dosimetry. The results of this work reveal the well-known disadvantages and/or problems of the conventional dosimeters for this kind of measurements and support that polymer gel dosimetry may overcome these problems. Conclusively, it is estimated that polymer gels could play an important role towards the minimization of the total SRS/SRT treatment error that is related with small field profile measurements.

  11. Dosimetry for synchrotron stereotactic radiotherapy: Monte Carlo simulations and radiosensitive gels; Dosimetrie pour la radiotherapie stereotaxique en rayonnement synchrotron: calculs Monte-Carlo et gels radiosensibles

    Energy Technology Data Exchange (ETDEWEB)

    Boudou, C

    2006-09-15

    High grade gliomas are extremely aggressive brain tumours. Specific techniques combining the presence of high atomic number elements within the tumour to an irradiation with a low x-rays (below 100 keV) beam from a synchrotron source were proposed. For the sake of clinical trials, the use of treatment planning system has to be foreseen as well as tailored dosimetry protocols. Objectives of this thesis work were (1) the development of a dose calculation tools based on Monte Carlo code for particles transport and (2) the implementation of an experimental method for the three dimensional verification of the dose delivered. The dosimetric tool is an interface between tomography images from patient or sample and the M.C.N.P.X. general purpose code. Besides, dose distributions were measured through a radiosensitive polymer gel, providing acceptable results compared to calculations.

  12. The use of gel dosimetry for verification of electron and photon treatment plans in carcinoma of the scalp

    International Nuclear Information System (INIS)

    Trapp, J V; Partridge, M; Hansen, V N; Childs, P; Bedford, J; Warrington, A P; Leach, M O; Webb, S

    2004-01-01

    In recent years there has been a large amount of research into the potential use of radiation sensitive gels for three-dimensional verification of clinical radiotherapy doses. In this paper we report the use of a MAGIC gel dosimeter (Fong et al 2001 Phys. Med. Biol. 46 3105) for the verification of a specific patient's radiation therapy dose distribution. A 69-year-old male patient presented with a squamous cell carcinoma extending approximately 180 deg. across the top of the scalp (anterior to posterior) and from just over midline to 90 deg. left of the skull. The patient's treatment was commenced using two electron fields. For gel dosimetry, phantoms were produced in which the outer surface spatially corresponded to the outer contours of the patient's anatomy in the region of irradiation. The phantoms were treated with either electrons or intensity modulated radiation therapy (IMRT) with photons. The results identified a hot spot between the matched electron fields and confirmed the more homogeneous dose distribution produced by the IMRT planning system. The IMRT plan was then clinically implemented. The application of a clinical dose to a phantom shaped to a specific patient as well as the ability to select a slice at will during phantom imaging means that gel dosimetry can no longer be considered to simply have potential alone, but is now in fact a useful dosimetric tool

  13. Adaptive mean filtering for noise reduction in CT polymer gel dosimetry

    International Nuclear Information System (INIS)

    Hilts, Michelle; Jirasek, Andrew

    2008-01-01

    X-ray computed tomography (CT) as a method of extracting 3D dose information from irradiated polymer gel dosimeters is showing potential as a practical means to implement gel dosimetry in a radiation therapy clinic. However, the response of CT contrast to dose is weak and noise reduction is critical in order to achieve adequate dose resolutions with this method. Phantom design and CT imaging technique have both been shown to decrease image noise. In addition, image postprocessing using noise reduction filtering techniques have been proposed. This work evaluates in detail the use of the adaptive mean filter for reducing noise in CT gel dosimetry. Filter performance is systematically tested using both synthetic patterns mimicking a range of clinical dose distribution features as well as actual clinical dose distributions. Both low and high signal-to-noise ratio (SNR) situations are examined. For all cases, the effects of filter kernel size and the number of iterations are investigated. Results indicate that adaptive mean filtering is a highly effective tool for noise reduction CT gel dosimetry. The optimum filtering strategy depends on characteristics of the dose distributions and image noise level. For low noise images (SNR ∼20), the filtered results are excellent and use of adaptive mean filtering is recommended as a standard processing tool. For high noise images (SNR ∼5) adaptive mean filtering can also produce excellent results, but filtering must be approached with more caution as spatial and dose distortions of the original dose distribution can occur

  14. Heterogeneity phantoms for visualization of 3D dose distributions by MRI-based polymer gel dosimetry

    International Nuclear Information System (INIS)

    Watanabe, Yoichi; Mooij, Rob; Mark Perera, G.; Maryanski, Marek J.

    2004-01-01

    Heterogeneity corrections in dose calculations are necessary for radiation therapy treatment plans. Dosimetric measurements of the heterogeneity effects are hampered if the detectors are large and their radiological characteristics are not equivalent to water. Gel dosimetry can solve these problems. Furthermore, it provides three-dimensional (3D) dose distributions. We used a cylindrical phantom filled with BANG-3 registered polymer gel to measure 3D dose distributions in heterogeneous media. The phantom has a cavity, in which water-equivalent or bone-like solid blocks can be inserted. The irradiated phantom was scanned with an magnetic resonance imaging (MRI) scanner. Dose distributions were obtained by calibrating the polymer gel for a relationship between the absorbed dose and the spin-spin relaxation rate of the magnetic resistance (MR) signal. To study dose distributions we had to analyze MR imaging artifacts. This was done in three ways: comparison of a measured dose distribution in a simulated homogeneous phantom with a reference dose distribution, comparison of a sagittally scanned image with a sagittal image reconstructed from axially scanned data, and coregistration of MR and computed-tomography images. We found that the MRI artifacts cause a geometrical distortion of less than 2 mm and less than 10% change in the dose around solid inserts. With these limitations in mind we could make some qualitative measurements. Particularly we observed clear differences between the measured dose distributions around an air-gap and around bone-like material for a 6 MV photon beam. In conclusion, the gel dosimetry has the potential to qualitatively characterize the dose distributions near heterogeneities in 3D

  15. Carbon beam dosimetry using VIP polymer gel and MRI

    DEFF Research Database (Denmark)

    Kantemiris, I; Petrokokkinos, L; Angelopoulos, A

    2009-01-01

    VIP polymer gel dosimeter was used for Carbon ion beam dosimetry using a 150 MeV/n beam with 10 Gy plateau dose and a SOBP irradiation scheme with 5 Gy Bragg peak dose. The results show a decrease by 8 mm in the expected from Monte Carlo simulation range in water, suggesting that the dosimeter...

  16. Dosimetry for synchrotron stereotactic radiotherapy: Monte Carlo simulations and radiosensitive gels

    International Nuclear Information System (INIS)

    Boudou, C.

    2006-09-01

    High grade gliomas are extremely aggressive brain tumours. Specific techniques combining the presence of high atomic number elements within the tumour to an irradiation with a low x-rays (below 100 keV) beam from a synchrotron source were proposed. For the sake of clinical trials, the use of treatment planning system has to be foreseen as well as tailored dosimetry protocols. Objectives of this thesis work were (1) the development of a dose calculation tools based on Monte Carlo code for particles transport and (2) the implementation of an experimental method for the three dimensional verification of the dose delivered. The dosimetric tool is an interface between tomography images from patient or sample and the M.C.N.P.X. general purpose code. Besides, dose distributions were measured through a radiosensitive polymer gel, providing acceptable results compared to calculations

  17. Trends in gel dosimetry: Preliminary bibliometric overview of active growth areas, research trends and hot topics from Gore’s 1984 paper onwards

    International Nuclear Information System (INIS)

    Baldock, C

    2017-01-01

    John Gore’s seminal 1984 paper on gel dosimetry spawned a vibrant research field ranging from fundamental science through to clinical applications. A preliminary bibliometric study was undertaken of the gel dosimetry family of publications inspired by, and resulting from, Gore’s original 1984 paper to determine active growth areas, research trends and hot topics from Gore’s paper up to and including 2016. Themes and trends of the gel dosimetry research field were bibliometrically explored by way of co-occurrence term maps using the titles and abstracts text corpora from the Web of Science database for all relevant papers from 1984 to 2016. Visualisation of similarities was used by way of the VOSviewer visualisation tool to generate cluster maps of gel dosimetry knowledge domains and the associated citation impact of topics within the domains. Heat maps were then generated to assist in the understanding of active growth areas, research trends, and emerging and hot topics in gel dosimetry. (paper)

  18. Standardization of the Fricke gel dosimetry method and tridimensional dose evaluation using the magnetic resonance imaging technique

    International Nuclear Information System (INIS)

    Cavinato, Christianne Cobello

    2009-01-01

    This study standardized the method for obtaining the Fricke gel solution developed at IPEN. The results for different gel qualities used in the preparation of solutions and the influence of the gelatin concentration in the response of dosimetric solutions were compared. Type tests such as: dose response dependence, minimum and maximum detection limits, response reproducibility, among others, were carried out using different radiation types and the Optical Absorption (OA) spectrophotometry and Magnetic Resonance (MR) techniques. The useful dose ranges for Co 60 gamma radiation and 6 MeV photons are 0,4 to 30,0 Gy and 0,5 to 100,0 Gy , using OA and MR techniques, respectively. A study of ferric ions diffusion in solution was performed to determine the optimum time interval between irradiation and samples evaluation; until 2,5 hours after irradiation to obtain sharp MR images. A spherical simulator consisting of Fricke gel solution prepared with 5% by weight 270 Bloom gelatine (national quality) was developed to be used to three-dimensional dose assessment using the Magnetic Resonance Imaging (MRI) technique. The Fricke gel solution prepared with 270 Bloom gelatine, that, in addition to low cost, can be easily acquired on the national market, presents satisfactory results on the ease of handling, sensitivity, response reproducibility and consistency. The results confirm their applicability in the three-dimensional dosimetry using MRI technique. (author)

  19. Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry

    Directory of Open Access Journals (Sweden)

    Timothy Olding

    2011-01-01

    Full Text Available This paper explores the combination of cone beam optical computed tomography with an N-isopropylacrylamide (NIPAM-based polymer gel dosimeter for three-dimensional dose imaging of small field deliveries. Initial investigations indicate that cone beam optical imaging of polymer gels is complicated by scattered stray light perturbation. This can lead to significant dosimetry failures in comparison to dose readout by magnetic resonance imaging (MRI. For example, only 60% of the voxels from an optical CT dose readout of a 1 l dosimeter passed a two-dimensional Low′s gamma test (at a 3%, 3 mm criteria, relative to a treatment plan for a well-characterized pencil beam delivery. When the same dosimeter was probed by MRI, a 93% pass rate was observed. The optical dose measurement was improved after modifications to the dosimeter preparation, matching its performance with the imaging capabilities of the scanner. With the new dosimeter preparation, 99.7% of the optical CT voxels passed a Low′s gamma test at the 3%, 3 mm criteria and 92.7% at a 2%, 2 mm criteria. The fitted interjar dose responses of a small sample set of modified dosimeters prepared (a from the same gel batch and (b from different gel batches prepared on the same day were found to be in agreement to within 3.6% and 3.8%, respectively, over the full dose range. Without drawing any statistical conclusions, this experiment gives a preliminary indication that intrabatch or interbatch NIPAM dosimeters prepared on the same day should be suitable for dose sensitivity calibration.

  20. Polymer gel dosimetry for synchrotron stereotactic radiotherapy and iodine dose-enhancement measurements

    International Nuclear Information System (INIS)

    Boudou, C; Tropres, I; Rousseau, J; Lamalle, L; Adam, J F; Esteve, F; Elleaume, H

    2007-01-01

    Synchrotron stereotactic radiotherapy (SSR) is a radiotherapy technique that makes use of the interactions of monochromatic low energy x-rays with high atomic number (Z) elements. An important dose-enhancement can be obtained if the target volume has been loaded with a sufficient amount of a high-Z element, such as iodine. In this study, we compare experimental dose measurements, obtained with normoxic polymer gel (nPAG), with Monte Carlo computations. Gels were irradiated within an anthropomorphic head phantom and were read out by magnetic resonance imaging. The dose-enhancement due to the presence of iodine in the gel (iodine concentration: 5 and 10 mg ml -1 ) was measured at two radiation energies (35 and 80 keV) and was compared to the calculated factors. nPAG dosimetry was shown to be efficient for measuring the sharp dose gradients produced by SSR. The agreement between 3D gel dosimetry and calculated dose distributions was found to be within 4% of the dose difference criterion and a distance to agreement of 2.1 mm for 80% of the voxels. Polymer gel doped with iodine exhibited higher sensitivity, in good agreement with the calculated iodine-dose enhancement. We demonstrate in this preliminary study that iodine-doped nPAG could be used for measuring in situ dose distributions for iodine-enhanced SSR treatment

  1. Feasibility of CBCT dosimetry for IMRT using a normoxic polymethacrylic-acid gel dosimeter

    Science.gov (United States)

    Bong, Ji Hye; Kwon, Soo-Il; Kim, Kum Bae; Kim, Mi Suk; Jung, Hai Jo; Ji, Young Hoon; Ko, In Ok; Park, Ji Ae; Kim, Kyeong Min

    2013-09-01

    The purpose of this study is to evaluate the availability of cone-beam computed tomography(CBCT) for gel dosimetry. The absorbed dose was analyzed by using intensity-modulated radiation therapy(IMRT) to irradiate several tumor shapes with a calculated dose and several tumor acquiring images with CBCT in order to verify the possibility of reading a dose on the polymer gel dosimeter by means of the CBCT image. The results were compared with those obtained using magnetic resonance imaging(MRI) and CT. The linear correlation coefficients at doses less than 10 Gy for the polymer gel dosimeter were 0.967, 0.933 and 0.985 for MRI, CT and CBCT, respectively. The dose profile was symmetric on the basis of the vertical axis in a circular shape, and the uniformity was 2.50% for the MRI and 8.73% for both the CT and the CBCT. In addition, the gradient in the MR image of the gel dosimeter irradiated in an H shape was 109.88 while the gradients of the CT and the CBCT were 71.95 and 14.62, respectively. Based on better image quality, the present study showed that CBCT dosimetry for IMRT could be restrictively performed using a normoxic polymethacrylic-acid gel dosimeter.

  2. Integration of Fricke gel dosimetry with Ag nanoparticles for experimental dose enhancement determination in theranostics

    International Nuclear Information System (INIS)

    Vedelago, J.; Valente, M.; Mattea, F.

    2017-10-01

    The use and implementation of nanoparticles in medicine has grown exponentially in the last twenty years. Their main applications include drug delivery, theranostics, tissue engineering and magneto function. Dosimetry techniques can take advantage of inorganic nanoparticles properties and their combination with gel dosimetry techniques could be used as a first step for their later inclusion in radio-diagnostics or radiotherapy treatments. This work presents preliminary results of properly synthesized and purify silver nanoparticles integration with Fricke gel dosimeters. Used nanoparticles presented mean sizes ranging from 2 to 20 nm, with a lognormal distribution. Xylenol orange concentration in Fricke gel dosimeter was adjust in order to allow sample optical readout, accounting nanoparticles plasmon. Dose enhancement was assessed irradiating dosimeters setting X-ray beams energies below and above silver K-edge. (Author)

  3. Integration of Fricke gel dosimetry with Ag nanoparticles for experimental dose enhancement determination in theranostics

    Energy Technology Data Exchange (ETDEWEB)

    Vedelago, J.; Valente, M. [Instituto de Fisica Enrique Gaviola - CONICET, Av. Medina Allende s/n, Ciudad Universitaria, X5000HUA Cordoba (Argentina); Mattea, F., E-mail: jvedelago@famaf.unc.edu.ar [Universidad Nacional de Cordoba, FAMAF, Laboratorio de Investigacion e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Av. Medina Allende s/n, Ciudad Universitaria, X5000HUA Cordoba (Argentina)

    2017-10-15

    The use and implementation of nanoparticles in medicine has grown exponentially in the last twenty years. Their main applications include drug delivery, theranostics, tissue engineering and magneto function. Dosimetry techniques can take advantage of inorganic nanoparticles properties and their combination with gel dosimetry techniques could be used as a first step for their later inclusion in radio-diagnostics or radiotherapy treatments. This work presents preliminary results of properly synthesized and purify silver nanoparticles integration with Fricke gel dosimeters. Used nanoparticles presented mean sizes ranging from 2 to 20 nm, with a lognormal distribution. Xylenol orange concentration in Fricke gel dosimeter was adjust in order to allow sample optical readout, accounting nanoparticles plasmon. Dose enhancement was assessed irradiating dosimeters setting X-ray beams energies below and above silver K-edge. (Author)

  4. Measurement of dynamic wedge angles and beam profiles by means of MRI ferrous sulphate gel dosimetry

    Science.gov (United States)

    Bengtsson, Magnus; Furre, Torbjørn; Rødal, Jan; Skretting, Arne; Olsen, Dag R.

    1996-02-01

    The purpose of this study is to examine the possible value of measuring the dose distribution in dynamic wedge photon beams using ferrous sulphate gel phantoms analysed by MRI. The wedge angles and dose profiles were measured for a field size of and for dynamic wedge angles of , , and using a 15 MV photon beam generated from a Clinac 2100 CD (Varian). The dose profiles obtained from MRI ferrous sulphate gel were in good agreement with the dose measurements performed with a diode detector array. Also, the wedge angles determined from the MRI ferrous sulphate gel agreed well with the values obtained by using film dosimetry and with calculations by use of TMS (treatment planning system) (Helax, Uppsala, Sweden). The study demonstrated that MRI ferrous sulphate gel dosimetry is an adequate tool for measurements of some beam characteristics of dynamic radiation fields.

  5. Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes.

    Science.gov (United States)

    Hayati, Homa; Mesbahi, Asghar; Nazarpoor, Mahmood

    2016-01-01

    Our purpose in the current study was to model an X-ray CT scanner with the Monte Carlo (MC) method for gel dosimetry. In this study, a conventional CT scanner with one array detector was modeled with use of the MCNPX MC code. The MC calculated photon fluence in detector arrays was used for image reconstruction of a simple water phantom as well as polyacrylamide polymer gel (PAG) used for radiation therapy. Image reconstruction was performed with the filtered back-projection method with a Hann filter and the Spline interpolation method. Using MC results, we obtained the dose-response curve for images of irradiated gel at different absorbed doses. A spatial resolution of about 2 mm was found for our simulated MC model. The MC-based CT images of the PAG gel showed a reliable increase in the CT number with increasing absorbed dose for the studied gel. Also, our results showed that the current MC model of a CT scanner can be used for further studies on the parameters that influence the usability and reliability of results, such as the photon energy spectra and exposure techniques in X-ray CT gel dosimetry.

  6. Fourier transform Raman spectroscopy of polyacrylamide gels for radiation dosimetry

    International Nuclear Information System (INIS)

    Baldock, C.; Murry, P.; Pope, J.; Rintoul, L.; George, G.

    1998-01-01

    Polyacrylamide (PAG) gels are used in magnetic resonance imaging radiation dosimetry. The PAG dosimeter is based on the radiation-induced co-polymerisation and cross-linking of acrylic monomers infused in a gel matrix. PAG was manufactured with a composition of 5% gelatine, 3% acrylamide and 3% N,N'methylene-bis-acrylamide by mass, with distilled water as the remaining constituent [Baldock, 1998]. FT-Raman spectroscopy studies were undertaken to investigate cross-linking changes during the co-polymerisation of PAG in the spectral range of 200 - 3500 cm -1 . Vibrational bands of 1285 cm -1 and 1256 cm -1 were assigned to the acrylamide and bis-acrylamide single CH 2 δ CH2 binding modes. These bands were found to decrease in amplitude with increasing absorbed radiation dose, as a result of co-polymerisation. Principal Component Regression was performed on FT-Raman spectra of PAG samples irradiated to 50 Gy and two components were found to be sufficient to account for 98.7% of variance in the data. Cross validation was used to establish the absorbed radiation dose of an unknown PAG sample from the FT-Raman spectra. The calculated correlation coefficient between measured and predictive samples was 0.997 with a standard error of estimate of 0.976 and a standard error of prediction of 1.140. These results demonstrate the potential of FT-Raman spectroscopy for ionising radiation dosimetry using polyacrylamide gels

  7. EGSnrc calculated and MRI-polymer gel dosimeter measured dose distribution of gamma knife in presence of inhomogeneities

    International Nuclear Information System (INIS)

    Allahverdi Pourfallah, T.; Allahverdi, M.; Riahi Alam, N.; Ay, M.; Zahmatkesh, M.; Ibbott, J.S.

    2008-01-01

    Stereotactic gamma-knife radiosurgery plays an important role in managing small intracranial brain lesions. Currently, polymer gel dosimetry is still the only dosimetry method for directly measuring three-dimensional dose distributions. polymer gel dosimeters are tissue equivalent and can act as a phantom material. In this study effects of inhomogeneities on those distributions have been investigated using both EGSnrc calculation and PAGAT polymer gel dosimeter. (author)

  8. Reproducibility and signal response linearity of Alanine gel dosimeter

    International Nuclear Information System (INIS)

    Silva, Cleber Feijo Silva; Campos, Leticia Lucente

    2008-01-01

    Gel Dosimetry has been studied mainly for medical applications, because it presents signal response in the dose range used in radiotherapy treatments and it can be applied for three dimensional dosimetry. Alanine gel dosimeter is a new gel material developed at IPEN that presents significant improvement on previous alanine systems developed by Costa (1994). The DL-Alanine (C 3 H 7 NO 2 ) is an amino acid tissue equivalent that improves the production of ferric ions in the solution. These ferric ions concentration can be measured by spectrophotometry technique. This work aims to study the reproducibility of the alanine gel solutions and the signal response as a function of gamma radiation dose, considering that these two properties are very important for characterizing and standardizing any dosimeter. (author)

  9. The use of polymer gel dosimetry to measure dose distribution around metallic implants

    International Nuclear Information System (INIS)

    Nagahata, Tomomasa; Yamaguchi, Hajime; Monzen, Hajime; Nishimura, Yasumasa

    2014-01-01

    A semi-solid polymer dosimetry system using agar was developed to measure the dose distribution close to metallic implants. Dosimetry of heterogeneous fields where electron density markedly varies is often problematic. This prompted us to develop a polymer gel dosimetry technique using agar to measure the dose distribution near substance boundaries. Varying the concentration of an oxygen scavenger (tetra-hydroxymethyl phosphonium chloride) showed the absorbed dose and transverse relaxation rate of the magnetic resonance signal to be linear between 3 and 12 Gy. Although a change in the dosimeter due to oxidization was observed in room air after 24 hours, no such effects were observed in the first 4 hours. The dose distribution around the metal implants was measured using agar dosimetry. The metals tested were a lead rod, a titanium hip joint, and a metallic stent. A maximum 30% dose increase was observed near the lead rod, but only a 3% increase in the absorbed dose was noted near the surface of the titanium hip joint and metallic stent. Semi-solid polymer dosimetry using agar thus appears to be a useful method for dosimetry around metallic substances. (author)

  10. [The use of polymer gel dosimetry to measure dose distribution around metallic implants].

    Science.gov (United States)

    Nagahata, Tomomasa; Yamaguchi, Hajime; Monzen, Hajime; Nishimura, Yasumasa

    2014-10-01

    A semi-solid polymer dosimetry system using agar was developed to measure the dose distribution close to metallic implants. Dosimetry of heterogeneous fields where electron density markedly varies is often problematic. This prompted us to develop a polymer gel dosimetry technique using agar to measure the dose distribution near substance boundaries. Varying the concentration of an oxygen scavenger (tetra-hydroxymethyl phosphonium chloride) showed the absorbed dose and transverse relaxation rate of the magnetic resonance signal to be linear between 3 and 12 Gy. Although a change in the dosimeter due to oxidization was observed in room air after 24 hours, no such effects were observed in the first 4 hours. The dose distribution around the metal implants was measured using agar dosimetry. The metals tested were a lead rod, a titanium hip joint, and a metallic stent. A maximum 30% dose increase was observed near the lead rod, but only a 3% increase in the absorbed dose was noted near the surface of the titanium hip joint and metallic stent. Semi-solid polymer dosimetry using agar thus appears to be a useful method for dosimetry around metallic substances.

  11. MAGAT gel dosimetry for its application in small field treatment techniques

    International Nuclear Information System (INIS)

    Gopishankar, N; Vivekanandhan, S; Kale, S S; Rath, G K; Kumaran, S Senthil; Thulkar, Sanjay; Subramani, V; Laviraj, M A; Bisht, R K; Mahapatra, A K

    2010-01-01

    Purpose of this work is to present the role of in-house manufactured MAGAT gel for treatment verification in small field dosimetric techniques such as Gammaknife (GK) and intensity-modulated radiation therapy (IMRT). Magnetic resonance imaging (MRI) is one of the most extensively used imaging technique for polymer gel dosimetry hence we used this method for gel evaluation. Different MR scanners and MRI sequences were used in this study for obtaining calibration plot between R2 and absorbed dose. An experimental plan was created for Gammaknife and IMRT. The prepared gel was filled in spherical glass phantom and in-house designed human head shape phantom for verification purpose. We used 8 TE values for all the imaging sequences for two reasons. Firstly it is sufficient enough to give good signal to noise ratio. Second considering the enormous scanning time involved in multiple spin echo sequence. MATLAB based in-house programs were used for R2 estimation and dose comparison. The isodose comparison with MAGAT gel showed reasonable agreement for both Gammaknife and IMRT techniques.

  12. Experimental determination of the diffusion coefficient in two-dimensions in ferrous sulphate gels using the finite element method

    International Nuclear Information System (INIS)

    Baldock, C.; Harris, P.J.; Piercy, A.R.; Healy, B.

    2001-01-01

    A novel two-dimensional finite element method for modelling the diffusion which occurs in Fricke or ferrous sulphate type radiation dosimetry gels is presented. In most of the previous work, the diffusion coefficient has been estimated using simple one-dimensional models. This work presents a two-dimensional model which enables the diffusion coefficient to be determined in a much wider range of experimental situations. The model includes the provision for the determination of a drift parameter. To demonstrate the technique comparative diffusion measurements between ferrous sulphate radiation dosimetry gels, with and without xylenol orange chelating agent and carbohydrate additives have been undertaken. Diffusion coefficients of 9.7±0.4, 13.3±0.6 and 9.5±0.8 10-3 cm 2 per h -1 were determined for ferrous sulphate radiation dosimetry gels with and without xylenol orange and with xylenol orange and sucrose additives respectively. Copyright (2001) Australasian College of Physical Scientists and Engineers in Medicine

  13. MRI gel dosimetry for verification of mono-isocentric junction doses in head and neck radiotherapy

    International Nuclear Information System (INIS)

    Back, S.A.J.; Jayasekera, P.M.; Lepage, M.; Baldock, C.; Menzies, N.; Back, P.

    2000-01-01

    Full text: The use of independent collimators in the abutment of two adjacent treatment volumes, as in head and neck radiation treatments, consists typically of positioning the collimator rotation axis (CRA) at the junction of the volumes, and offsetting each field by its half-field width. This has the effect of positioning one of the collimator jaws at the CRA for each field. However, misalignment of the jaws can lead to variations in dose uniformity in the junction region. We have used gel dosimetry to measure junction doses in three dimensions. PAG gel MRI was used to investigate junction dosimetry for a mono-isocentriic treatment of two orthogonal pairs of opposed (ant/post and lateral) 6 MV x-ray beams. PAG gels in an 11cm diameter cylindrical gel phantom were imaged using a Siemens Vision 1.5 T MRI. The exposures were made using a Philips SL 20 linear accelerator with independent jaws that were known to overlap at the isocentre for sequential abutting offset (within manufacturer's specifications for symmetric fields). X-Omat V films were exposed in mono-directional beams, and optically scanned for comparison. Measurements of off-axis ratios and of relative depth profiles using gel MRI and perpendicular film were in excellent agreement with each other. Measurements through the multi-directional junction at the isocentre are illustrated in the graph, for orthogonal planes centred at the isocentre of the neck phantom. They demonstrate a minimum dose of 75 % of that of the adjacent 'treatment' regions, which agrees closely with the results measured (72%) in the mono-directional case with film. We conclude that this measurement confirms that junction dosimetry at the isocentre measured with perpendicular film for a single direction is a good approximation to the situation in multiple directions. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  14. Reduced dose uncertainty in MRI-based polymer gel dosimetry using parallel RF transmission with multiple RF sources

    International Nuclear Information System (INIS)

    Sang-Young Kim; Jung-Hoon Lee; Jin-Young Jung; Do-Wan Lee; Seu-Ran Lee; Bo-Young Choe; Hyeon-Man Baek; Korea University of Science and Technology, Daejeon; Dae-Hyun Kim; Jung-Whan Min; Ji-Yeon Park

    2014-01-01

    In this work, we present the feasibility of using a parallel RF transmit with multiple RF sources imaging method (MultiTransmit imaging) in polymer gel dosimetry. Image quality and B 1 field homogeneity was statistically better in the MultiTransmit imaging method than in conventional single source RF transmission imaging method. In particular, the standard uncertainty of R 2 was lower on the MultiTransmit images than on the conventional images. Furthermore, the MultiTransmit measurement showed improved dose resolution. Improved image quality and B 1 homogeneity results in reduced dose uncertainty, thereby suggesting the feasibility of MultiTransmit MR imaging in gel dosimetry. (author)

  15. Investigation of optimal scanning protocol for X-ray computed tomography polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Sellakumar, P. [Bangalore Institute of Oncology, 44-45/2, II Cross, RRMR Extension, Bangalore 560 027 (India)], E-mail: psellakumar@rediffmail.com; James Jebaseelan Samuel, E. [School of Science and Humanities, VIT University, Vellore 632 014 (India); Supe, Sanjay S. [Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Hosur Road, Bangalore 560 027 (India)

    2007-11-15

    X-ray computed tomography is one of the potential tool used to evaluate the polymer gel dosimeters in three dimensions. The purpose of this study is to investigate the factors which affect the image noise for X-ray CT polymer gel dosimetry. A cylindrical water filled phantom was imaged with single slice Siemens Somatom Emotion CT scanner. The imaging parameters like tube voltage, tube current, slice scan time, slice thickness and reconstruction algorithm were varied independently to study the dependence of noise on each other. Reductions of noise with number of images to be averaged and spatial uniformity of the image were also investigated. Normoxic polymer gel PAGAT was manufactured and irradiated using Siemens Primus linear accelerator. The radiation induced change in CT number was evaluated using X-ray CT scanner. From this study it is clear that image noise is reduced with increase in tube voltage, tube current, slice scan time, slice thickness and also reduced with increasing the number of images averaged. However to reduce the tube load and total scan time, it was concluded that tube voltage of 130 kV, tube current of 200 mA, scan time of 1.5 s, slice thickness of 3 mm for high dose gradient and 5 mm for low dose gradient were optimal scanning protocols for this scanner. Optimum number of images to be averaged was concluded to be 25 for X-ray CT polymer gel dosimetry. Choice of reconstruction algorithm was also critical. From the study it is also clear that CT number increase with imaging tube voltage and shows the energy dependency of polymer gel dosimeter. Hence for evaluation of polymer gel dosimeters with X-ray CT scanner needs the optimization of scanning protocols to reduce the image noise.

  16. A fast dual wavelength laser beam fluid-less optical CT scanner for radiotherapy 3D gel dosimetry II: dosimetric performance

    Science.gov (United States)

    Ramm, Daniel

    2018-02-01

    New clinical radiotherapy dosimetry systems need comprehensive demonstration of measurement quality. Practicality and reliability are other important aspects for clinical dosimeters. In this work the performance of an optical CT scanner for true 3D dosimetry is assessed using a radiochromic gel dosimeter. The fluid-less scanner utilised dual lasers to avoid the necessity for pre-irradiation scans and give greater robustness of image quality, enhancing practicality. Calibration methods using both cuvettes and reconstructed volumes were developed. Dosimetric accuracy was similar for dual and single wavelength measurements, except that cuvette calibration reliability was reduced for dual wavelength without pre-irradiation scanning. Detailed performance parameters were specified for the dosimetry system indicating the suitability for clinical use. The most significant limitations of the system were due to the gel dosimeter rather than the optical CT scanner. Quality assurance guidelines were developed to maintain dosimetry system performance in routine use.

  17. Explorative data analysis of two-dimensional electrophoresis gels

    DEFF Research Database (Denmark)

    Schultz, J.; Gottlieb, D.M.; Petersen, Marianne Kjerstine

    2004-01-01

    of gels is presented. First, an approach is demonstrated in which no prior knowledge of the separated proteins is used. Alignment of the gels followed by a simple transformation of data makes it possible to analyze the gels in an automated explorative manner by principal component analysis, to determine......Methods for classification of two-dimensional (2-DE) electrophoresis gels based on multivariate data analysis are demonstrated. Two-dimensional gels of ten wheat varieties are analyzed and it is demonstrated how to classify the wheat varieties in two qualities and a method for initial screening...... if the gels should be further analyzed. A more detailed approach is done by analyzing spot volume lists by principal components analysis and partial least square regression. The use of spot volume data offers a mean to investigate the spot pattern and link the classified protein patterns to distinct spots...

  18. MO-B-BRB-04: 3D Dosimetry in End-To-End Dosimetry QA

    Energy Technology Data Exchange (ETDEWEB)

    Ibbott, G. [UT MD Anderson Cancer Center (United States)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  19. Initial experiments with gel-water: towards MRI-linac dosimetry and imaging.

    Science.gov (United States)

    Alnaghy, Sarah J; Gargett, Maegan; Liney, Gary; Petasecca, Marco; Begg, Jarrad; Espinoza, Anthony; Newall, Matthew K; Duncan, Mitchell; Holloway, Lois; Lerch, Michael L F; Lazea, Mircea; Rosenfeld, Anatoly B; Metcalfe, Peter

    2016-12-01

    Tracking the position of a moving radiation detector in time and space during data acquisition can replicate 4D image-guided radiotherapy (4DIGRT). Magnetic resonance imaging (MRI)-linacs need MRI-visible detectors to achieve this, however, imaging solid phantoms is an issue. Hence, gel-water, a material that provides signal for MRI-visibility, and which will in future work, replace solid water for an MRI-linac 4DIGRT quality assurance tool, is discussed. MR and CT images of gel-water were acquired for visualisation and electron density verification. Characterisation of gel-water at 0 T was compared to Gammex-RMI solid water, using MagicPlate-512 (M512) and RMI Attix chamber; this included percentage depth dose, tissue-phantom ratio (TPR 20/10 ), tissue-maximum ratio (TMR), profiles, output factors, and a gamma analysis to investigate field penumbral differences. MR images of a non-powered detector in gel-water demonstrated detector visualisation. The CT-determined gel-water electron density agreed with the calculated value of 1.01. Gel-water depth dose data demonstrated a maximum deviation of 0.7% from solid water for M512 and 2.4% for the Attix chamber, and by 2.1% for TPR 20/10 and 1.0% for TMR. FWHM and output factor differences between materials were ≤0.3 and ≤1.4%. M512 data passed gamma analysis with 100% within 2%, 2 mm tolerance for multileaf collimator defined fields. Gel-water was shown to be tissue-equivalent for dosimetry and a feasible option to replace solid water.

  20. Measurement of the three-dimensional distribution of radiation dose in grid therapy

    International Nuclear Information System (INIS)

    Trapp, J V; Warrington, A P; Partridge, M; Philps, A; Glees, J; Tait, D; Ahmed, R; Leach, M O; Webb, S

    2004-01-01

    A single large dose of megavoltage x-rays delivered through a grid is currently being utilized by some centres for palliative radiotherapy treatments of large tumours. In this note, we investigate the dosimetry of grid therapy using two-dimensional film dosimetry and three-dimensional gel dosimetry. It is shown that the radiation dose is attenuated more rapidly with depth in a grid field than an open field, and that even shielded regions receive approximately 25% of the dose to the unshielded areas. (note)

  1. Three dimensional measurement of dose distributions produced by a robot-mounted linac using magnetic resonance imaging of bang polymer gel dosimeters

    International Nuclear Information System (INIS)

    Wong, S.P.; Garwood, D.P.; Clarke, G.D.; McColl, R.W.; Maryanski, M.J.; Gore, J.C.

    1996-01-01

    Purpose/Objective: A novel image-guided robotic radiosurgical system, capable of irradiating 102 non-coplanar nodes in 3 π geometry, produces complex dose distributions which are difficult or impractical to measure with conventional dosimetry instrumentation. The recently developed BANG polymer gel dosimetry system provides accurate, high resolution and three dimensional dose distributions data and is ideally suited for the task described above. In this study, the polymer gels were used for imaging the dose distributions produced by this extremely flexible radiosurgical system. Materials and Methods: The dosimeter materials consist of 2-liter BANG polymer gels in spherical, clear glass flasks, closed with ground glass stoppers, with glass rods extending to the center of the gel that serve as a target for the frameless robotic radiosurgery. A compact 6 MV x-band linac (285 lbs) is mounted and maneuvered by a 6 degree-of-freedom robotic arm. The gels were irradiated using a 25 mm circular insert. A total of 10 Gy was delivered at isocenter at a dose rate of 300 cGy/min using all of the available 102 nodes. The gels were then imaged by MRI(GE Signa) at 1.5 T, using a series of Hahn spin echoes of TR = 3s, TE = 20,100,200,400 ms. Transverse relaxation rate (R 2 ) maps were constructed from those multiple images, using the non-linear least-squares Lavenberg-Marquardt algorithm and a data analysis and display program 'DoseMap' which was written using the scientific computational program MATLAB. R 2 maps were converted to dose maps using an R 2 -to-dose calibration curve. Dose maps and isodose curves were then compared with corresponding data from the treatment planning computer software. Results: The dose dependence of the NMR transverse relaxation rate, R 2 , is reproducible (less than 2 % variation) and is linear up to about 10 Gy, with a slope of 0.25 s -1 Gy -1 at 1.5 Tesla. Isodose curves in three orthogonal (axial, sagittal and coronal) planes show excellent

  2. Fast, three-dimensional, MR Imaging for polymer gel dosimetric applications involving high dose and steep dose gradients

    International Nuclear Information System (INIS)

    Sandilos, Panagiotis; Baras, Panagiotis; Georgiou, Evangelos; Dardoufas, Konstantinos; Karaiskos, Pantelis; Papagiannis, Panagiotis; Paschalis, Theodoros; Tatsis, Elias; Torrens, Michael; Vlahos, Lampros

    2006-01-01

    Polymer gels constitute water equivalent integrating detectors, which, combined with magnetic resonance imaging (MRI), can provide accurate three dimensional (3D) dose distributions in contemporary radiotherapy applications where the small field dimensions and steep dose gradients induce limitations to conventional dosimeters. One of the main obstacles for adapting the method for routine use in the clinical setting is the cost effectiveness of the MRI readout method. Currently, optimized Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo imaging pulse sequences are commonly used which however result in long imaging times. This work evaluates the efficiency of 3D, dual-echo, k-space segmented turbo spin echo (TSE) scanning sequences for accurate dosimetry with sub-millimetre spatial resolution in strenuous radiation therapy applications. PABIG polymer gel dosimeters were irradiated with an 192 Ir High Dose Rate brachytherapy source, the 4 mm and 8 mm collimator helmets of a gamma knife unit and a custom made x-knife collimator of 1 cm diameter. Profile and dose distribution measurements using TSE are benchmarked against corresponding findings obtained by the commonly used, but time consuming, CPMG sequence as well as treatment planning calculations, Monte Carlo (MC) simulations and film measurements. The implementation of a high Turbo factor was found to provide comparable accuracy, allowing a 64-fold MRI scan acceleration compared to conventional multi-echo sequences. The availability of TSE sequences in typical MRI installations greatly facilitates the introduction of polymer gel dosimetry in the clinical environment as a practicable tool for the determination of full 3D dose distributions in contemporary radiotherapy applications

  3. Fast, three-dimensional, MR Imaging for polymer gel dosimetric applications involving high dose and steep dose gradients

    Energy Technology Data Exchange (ETDEWEB)

    Sandilos, Panagiotis [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Baras, Panagiotis [Philips Hellas Medical Systems, 44 Kifissias Ave., Maroussi 151 25, Athens (Greece); Georgiou, Evangelos [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece); Dardoufas, Konstantinos [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece): Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Karaiskos, Pantelis [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece): Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece)]. E-mail: p.karaiskos@hygeia.gr; Papagiannis, Panagiotis [Physics Department, Nuclear and Particle Physics Section, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Paschalis, Theodoros [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Tatsis, Elias [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece); Torrens, Michael [Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Vlahos, Lampros [Department of Radiology, Medical School, University of Athens, Areteion Hospital, 76 Vas. Sofias Ave., 115 28 Athens (Greece)

    2006-12-20

    Polymer gels constitute water equivalent integrating detectors, which, combined with magnetic resonance imaging (MRI), can provide accurate three dimensional (3D) dose distributions in contemporary radiotherapy applications where the small field dimensions and steep dose gradients induce limitations to conventional dosimeters. One of the main obstacles for adapting the method for routine use in the clinical setting is the cost effectiveness of the MRI readout method. Currently, optimized Carr-Purcell-Meiboom-Gill (CPMG) multiple spin echo imaging pulse sequences are commonly used which however result in long imaging times. This work evaluates the efficiency of 3D, dual-echo, k-space segmented turbo spin echo (TSE) scanning sequences for accurate dosimetry with sub-millimetre spatial resolution in strenuous radiation therapy applications. PABIG polymer gel dosimeters were irradiated with an {sup 192}Ir High Dose Rate brachytherapy source, the 4 mm and 8 mm collimator helmets of a gamma knife unit and a custom made x-knife collimator of 1 cm diameter. Profile and dose distribution measurements using TSE are benchmarked against corresponding findings obtained by the commonly used, but time consuming, CPMG sequence as well as treatment planning calculations, Monte Carlo (MC) simulations and film measurements. The implementation of a high Turbo factor was found to provide comparable accuracy, allowing a 64-fold MRI scan acceleration compared to conventional multi-echo sequences. The availability of TSE sequences in typical MRI installations greatly facilitates the introduction of polymer gel dosimetry in the clinical environment as a practicable tool for the determination of full 3D dose distributions in contemporary radiotherapy applications.

  4. Incorporating multislice imaging into x-ray CT polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, H., E-mail: holly.johnston@utsw.edu [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2 (Canada); Hilts, M. [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2, Canada and Medical Physics, BC Cancer Agency, Vancouver Island Centre, Victoria, British Columbia V8R 6V5 (Canada); Jirasek, A. [Department of Physics and Astronomy, University of Victoria, Victoria, British Columbia V8W 2Y2, Canada and Department of Physics, University of British Columbia—Okanagan Campus, Kelowna, British Columbia V1V 1V7 (Canada)

    2015-04-15

    Purpose: To evaluate multislice computed tomography (CT) scanning for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD) and to establish a baseline assessment of image noise and uniformity in an unirradiated gel dosimeter. Methods: A 16-slice CT scanner was used to acquire images through a 1 L cylinder filled with water. Additional images were collected using a single slice machine. The variability in CT number (N{sub CT}) associated with the anode heel effect was evaluated and used to define a new slice-by-slice background subtraction artifact removal technique for CT PGD. Image quality was assessed for the multislice system by evaluating image noise and uniformity. The agreement in N{sub CT} for slices acquired simultaneously using the multislice detector array was also examined. Further study was performed to assess the effects of increasing x-ray tube load on the constancy of measured N{sub CT} and overall scan time. In all cases, results were compared to the single slice machine. Finally, images were collected throughout the volume of an unirradiated gel dosimeter to quantify image noise and uniformity before radiation is delivered. Results: Slice-by-slice background subtraction effectively removes the variability in N{sub CT} observed across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image noise was higher for the multislice system compared to the single slice scanner, but overall image quality was comparable between the two systems. Further study showed N{sub CT} was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thicknesses examined. In addition, the multislice system was found to eliminate variations in N{sub CT} due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to

  5. Image registration of BANG[reg] gel dose maps for quantitative dosimetry verification

    International Nuclear Information System (INIS)

    Meeks, Sanford L.; Bova, Frank J.; Maryanski, Marek J.; Kendrick, Lance A.; Ranade, Manisha K.; Buatti, John M.; Friedman, William A.

    1999-01-01

    Background: The BANG[reg] (product symbol SGEL, MGS Research Inc., Guilford, CT) polymer gel has been shown to be a valuable dosimeter for determining three-dimensional (3D) dose distributions. Because the proton relaxation rate (R2) of the gel changes as a function of absorbed dose, MR scans of the irradiated gel can be used to generate 3D dose maps. Previous work with the gel, however, has not relied on precise localization of the measured dose distribution. This has limited its quantitative use, as no precise correlation exists with the planned distribution. This paper reports on a technique for providing this correlation, thus providing a quality assurance tool that includes all of the steps of imaging, treatment planning, dose calculation, and treatment localization. Methods and Materials: The BANG[reg] gel formulation was prepared and poured into spherical flasks (15.3-cm inner diameter). A stereotactic head ring was attached to each flask. Three magnetic resonance imaging (MRI) and computed tomography (CT) compatible fiducial markers were placed on the flask, thus defining the central axial plane. A high-resolution CT scan was obtained of each flask. These images were transferred to a radiosurgery treatment-planning program, where treatment plans were developed. The gels were irradiated using our systems for stereotactic radiosurgery or fractionated stereotactic radiotherapy. The gels were MR imaged, and a relative 3D dose map was created from an R2 map of these images. The dose maps were transferred to an image-correlation program, and then fused to the treatment-planning CT scan through a rigid body match of the MRI/CT-compatible fiducial markers. The fused dose maps were imported into the treatment-planning system for quantitative comparison with the calculated treatment plans. Results: Calculated and measured isodose surfaces agreed to within 2 mm at the worst points within the in-plane dose distributions. This agreement is excellent, considering that

  6. Gel dosimetry - a laser based 3D scanner for gel samples - research in India

    Energy Technology Data Exchange (ETDEWEB)

    Widmer, Johannes [Institut fuer Angewandte Photophysik, TU Dresden (Germany); Photonics Division, VIT University, Vellore, Tamil Nadu (India); Dhiviyaraj Kalaiselven, Senthil Kumar [Photonics Division, VIT University, Vellore, Tamil Nadu (India); Department of Therapeutic Radiology, University of Minnesota, Minneapolis (United States); James, Jebaseelan Samuel [Photonics Division, VIT University, Vellore, Tamil Nadu (India)

    2013-07-01

    A laser based 3D scanner is developed to take tomography images of partly transparent samples. The scanner is optimized to characterize gel samples from spatially resolved dosimetry measurements. The resulting device should be suitably designed to be constructed in India. This gave me valuable insight into the scientific and technological environment of the country and made me find my way through a quite different culture of research and commerce, within and beyond the scientific context of the university. The project was implemented during a nine months stay at the Vellore Institute of Technology University in Vellore, Tamil Nadu, India, in co-operation with the Christian Medical College, Vellore, in 2006/07. It was conducted within the framework of existing research activities of the host university.

  7. Application of gel dosimetry - A preliminary study on verification of uniformity of activity and length of source used in Beta-Cath system

    International Nuclear Information System (INIS)

    Subramaniam, S.; Rabi Raja Singh, I.; Visalatchi, S.; Paul Ravindran, B.

    2002-01-01

    Recently the intraluminal irradiation of coronary arteries following balloon angioplasty is found to reduce proliferation of smooth muscle cells and restenosis. Among the isotopes used for the intracoronary irradiation, 90 Sr/Y appears to be ideal (H I Almos et al, 1996). In 1984 Gore et al proposed that radiation induced changes in the well-established Fricke solution could be probed with Nuclear Magnetic Resonance (NMR) relaxation measurements rather than using conventional spectrophotometry measurements. This was a major step in the development of gel dosimetry and since then gel dosimetry has been one of the major advances in the dosimetry of complex radiation fields has been in the area of gel dosimetry. In this preliminary work on gel dosimetry we present the verification of uniformity of activity along the length of the source train and verification of the length of the source used in the Beta-Cath system used for intracoronary brachytherapy with ferrous gel dosimeter. The Beta-Cath system obtained from Novoste, Norcross, GA was used in this study. It consists of a source train of 16 90 Sr/Y sources each of length 2.5mm. The total length of the source train is 40mm. For preparation of the Ferrous-Gelatin Gel, the recipe provided by the London Regional Cancer Center, London Ontario, Canada was used. Stock solutions of 50mM H 2 SO 4 , 0.3 mM ferrous ammonium sulphate, 0.05mM Xylenol orange was first prepared. The gel was prepared by mixing 4% gelatin with distilled water while stirring in a water bath at 40-42 deg. C. Acid solution, Ferrous ammonium sulphate solution and Xylenol orange were added and stirred in the water bath for about an hour to allow aeration. The mixture was poured in to three 20ml syringes to form the gel and stored in the refrigerator at 5 deg. C. For irradiation with Beta-Cath, the gel was prepared in three cylindrical 20ml syringes. A nylon tube having the same dimension as that of the delivery catheter used in intra-coronary was placed

  8. Verification of motion induced thread effect during tomotherapy using gel dosimetry

    International Nuclear Information System (INIS)

    Edvardsson, Anneli; Ljusberg, Anna; Ceberg, Crister; Medin, Joakim; Ambolt, Lee; Nordström, Fredrik; Ceberg, Sofie

    2015-01-01

    The purpose of the study was to evaluate how breathing motion during tomotherapy (Accuray, CA, USA) treatment affects the absorbed dose distribution. The experiments were carried out using gel dosimetry and a motion device simulating respiratory-like motion (HexaMotion, ScandiDos, Uppsala, Sweden). Normoxic polyacrylamide gels (nPAG) were irradiated, both during respiratory-like motion and in a static mode. To be able to investigate interplay effects the static absorbed dose distribution was convolved with the motion function and differences between the dynamic and convolved static absorbed dose distributions were interpreted as interplay effects. The expected dose blurring was present and the interplay effects formed a spiral pattern in the lower dose volume. This was expected since the motion induced affects the preset pitch and the theoretically predicted thread effect may emerge. In this study, the motion induced thread effect was experimentally verified for the first time

  9. Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry

    International Nuclear Information System (INIS)

    Pavoni, J. F.; Pike, T. L.; Snow, J.; DeWerd, L.; Baffa, O.

    2012-01-01

    Purpose: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. Methods: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging. Results: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%/3 mm and of 96.5% using 4%/4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves. Conclusions: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements.

  10. Tomotherapy dose distribution verification using MAGIC-f polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Pavoni, J. F.; Pike, T. L.; Snow, J.; DeWerd, L.; Baffa, O. [Departamento de Fisica, Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto-Universidade de Sao Paulo, Av. Bandeirantes, 3900 - CEP 14040-901 - Bairro Monte Alegre - Ribeirao Preto, SP (Brazil); Medical Radiation Research Center, Department of Medical Physics, University of Wisconsin, 1111 Highland Avenue, B1002 WIMR, Madison, Wisconsin 53705-2275 (United States); Departamento de Fisica, Faculdade de Filosofia Ciencias e Letras de Ribeirao Preto-Universidade de Sao Paulo, Av. Bandeirantes, 3900 - CEP 14040-901 - Bairro Monte Alegre - Ribeirao Preto, SP (Brazil)

    2012-05-15

    Purpose: This paper presents the application of MAGIC-f gel in a three-dimensional dose distribution measurement and its ability to accurately measure the dose distribution from a tomotherapy unit. Methods: A prostate intensity-modulated radiation therapy (IMRT) irradiation was simulated in the gel phantom and the treatment was delivered by a TomoTherapy equipment. Dose distribution was evaluated by the R2 distribution measured in magnetic resonance imaging. Results: A high similarity was found by overlapping of isodoses of the dose distribution measured with the gel and expected by the treatment planning system (TPS). Another analysis was done by comparing the relative absorbed dose profiles in the measured and in the expected dose distributions extracted along indicated lines of the volume and the results were also in agreement. The gamma index analysis was also applied to the data and a high pass rate was achieved (88.4% for analysis using 3%/3 mm and of 96.5% using 4%/4 mm). The real three-dimensional analysis compared the dose-volume histograms measured for the planning volumes and expected by the treatment planning, being the results also in good agreement by the overlapping of the curves. Conclusions: These results show that MAGIC-f gel is a promise for tridimensional dose distribution measurements.

  11. SU-F-T-565: Assessment of Dosimetric Accuracy for a 3D Gel-Based Dosimetry Service

    Energy Technology Data Exchange (ETDEWEB)

    Rosen, B; Lam, K; Moran, J [University Michigan Medical Center, Ann Arbor, MI (United States)

    2016-06-15

    Purpose: To assess the 3D dosimetric accuracy when using a mail-in service for square and stereotactic fields in a clinical environment. Methods: The 3D dosimetry mail-in service (3DDaaS), offered by Modus QA (London, ON), was used to measure dose distributions from a 6 MV beam of a Varian Clinac. Plastic jars filled with radiosensitive ClearView™ gel were received, CT scanned (for registration and density information), irradiated, and then mailed back to the manufacturer for optical CT readout. Three square field irradiations (2×2, 4×4, and 10×10 cm{sup 2}) were performed with jars immobilized in a water tank, and a composite small-field stereotactic delivery was performed using an in-air holder. Dosimetric properties of the gel were quantified within the 25–50 Gy dose range using 3D optical attenuation (OA) distributions provided by the manufacturer. OA was normalized to 100% at the position of isocenter, which received 40Gy. Percentage depth dose, profiles, and 3D gamma distributions (3%/1mm criteria) were calculated to quantify feasibility for relative dosimetry. Results: Mean CT-measured density in the central (3×3×3) cm{sup 3} gel region was 40 ± 3 HU, indicating good homogeneity and near-water-equivalence. Measured and calculated central axis doses agreed to within ±3% in the 25–50 Gy dose range. For the square field irradiations, dose profiles agreed to within 1mm. Gamma analysis of the composite irradiation yielded 99.8%, 91.4%, and 79.1% passing rates for regions receiving at least 10, 5, and 2 Gy, respectively, indicating feasibility for use in high-dose regions. Absolute response varied by up to 16% between jars, indicating limitations for absolute dosimetry under the mail-in conditions. Conclusion: 3DDaaS is a novel near-water-equivalent dosimetry system accurate to within 3% dose and 1mm 3D spatial resolution, and is straightforward to use in a clinical setting. Future investigations are warranted to improve dosimeter response in low

  12. Development of a three-dimensional radiation dosimetry system

    International Nuclear Information System (INIS)

    Bero, M.A.

    2001-12-01

    The direct non-destructive measurement of the radiation absorbed dose in three dimensions is considered to be technically difficult. Accurate determination of the spatial distribution of absorbed dose plays an important role in many applications particularly in medicine. In radiotherapy computer calculations are frequently used to estimate three-dimensional dose distributions in complex geometry, hence a practical dosimetry system able to provide three-dimensional (3-D) integrated measurements is highly desirable for verifying such dose predictions. Magnetic Resonance Imaging (MRI) has been used to visualise 3-D dose distributions, inside two different detector materials, namely the ferrous sulphate gel (Fricke gel) and the polymer gel system. Each of these procedures has its own drawbacks and limitations, and this research project sought to find improvements and alternatives to overcome these problems. Work on the Fricke gel led to an improved preparation procedure employing gelatin gel whose lower melting point reduces the possibility of dissolved oxygen loss. The role of each component was clarified which led to the omission of all unnecessary chemicals such as the sodium chloride and benzoic acid. Initially MRI was the only 3-D readout technique available, however simple relaxometry was used to characterise the detector quantitatively with each modification before employing an MRI scanner to obtain images. Optimisation of the active constituents saves time and effort, and minimises the cost of equipment as well as materials. A serious drawback of the Fricke gel is ion diffusion, which causes blurring of the recorded spatial distribution and much effort was given to attempts to reduce this. However it was concluded that it is possible to slow down ion diffusion but at the cost of detector sensitivity. Therefore the best way of dealing with this problem is by introducing a fast readout technique so that the dose distribution can be recorded before serious

  13. Dependence of alanine gel dosimeter response as a function of photon clinical beams dose rate

    International Nuclear Information System (INIS)

    Silva, Cleber Feijo; Campos, Leticia Lucente

    2013-01-01

    Gel dosimetry is a new area developed by Gore, it is ery useful for application in radiotherapy because using NMR imaging as evaluation technique is possible to evaluate three dimensional absorbed dose distribution. The measure technique is based on difference of ferrous (Fe 2+ ) and ferric (Fe 3+ ) ) ions concentration that can be measured also by spectrophotometry technique. The Alanine gel dosimeter was developed at IPEN. The alanine is an amino acid and tissue equivalent material that presents significant improvement on previous alanine dosimetry systems. The addition of Alanine increases the production of ferric ions in the solution. This work aims to study the dose rate dependence of photon clinical beams radiation on the alanine gel dosimeter optical response, as well as the response repeatability and gel production reproducibility, since this property is very important for characterization and standardization of any dosimeter. (author)

  14. Matching Two-dimensional Gel Electrophoresis' Spots

    DEFF Research Database (Denmark)

    Dos Anjos, António; AL-Tam, Faroq; Shahbazkia, Hamid Reza

    2012-01-01

    This paper describes an approach for matching Two-Dimensional Electrophoresis (2-DE) gels' spots, involving the use of image registration. The number of false positive matches produced by the proposed approach is small, when compared to academic and commercial state-of-the-art approaches. This ar...

  15. Application of monomer/polymer gel dosimetry to study the effects of tissue inhomogeneities on intensity-modulated radiation therapy (IMRT) dose distributions.

    Science.gov (United States)

    Vergote, Koen; De Deene, Yves; Claus, Filip; De Gersem, Werner; Van Duyse, Bart; Paelinck, Leen; Achten, Eric; De Neve, Wilfried; De Wagter, Carlos

    2003-04-01

    When planning an intensity-modulated radiation therapy (IMRT) treatment in a heterogeneous region (e.g. the thorax), the dose computation algorithm of a treatment planning system may need to account for these inhomogeneities in order to obtain a reliable prediction of the dose distribution. An accurate dose verification technique such as monomer/polymer gel dosimetry is suggested to verify the outcome of the planning system. The effects of low-density structures: (a) on narrow high-energy (18 MV) photon beams; and (b) on a class-solution IMRT treatment delivered to a thorax phantom have been examined using gel dosimetry. The used phantom contained air cavities that could be filled with water to simulate a homogeneous or heterogeneous configuration. The IMRT treatment for centrally located lung tumors was delivered on both cases, and gel derived dose maps were compared with computations by both the GRATIS and Helax-TMS planning system. Dose rebuildup due to electronic disequilibrium in a narrow photon beam is demonstrated. The gel measurements showed good agreement with diamond detector measurements. Agreement between measured IMRT dose maps and dose computations was demonstrated by several quantitative techniques. An underdosage of the planning target volume (PTV) was revealed. The homogeneity of the phantom had only a minor influence on the dose distribution in the PTV. An expansion of low-level isodoses in the lung volume was predicted by collapsed cone computations in the heterogeneous case. For the class-solution described, the dose in centrally located mediastinal tumors can be computed with sufficient accuracy, even when neglecting the lower lung density. Polymer gel dosimetry proved to be a valuable technique to verify dose calculation algorithms for IMRT in 3D in heterogeneous configurations.

  16. Validation and application of polymer gel dosimetry for the dose verification of an intensity-modulated arc therapy (IMAT) treatment

    International Nuclear Information System (INIS)

    Vergote, K; Deene, Y de; Duthoy, W; Gersem, W de; Neve, W de; Achten, E; Wagter, C de

    2004-01-01

    Polymer gel dosimetry was used to assess an intensity-modulated arc therapy (IMAT) treatment for whole abdominopelvic radiotherapy. Prior to the actual dosimetry experiment, a uniformity study on an unirradiated anthropomorphic phantom was carried out. A correction was performed to minimize deviations in the R2 maps due to radiofrequency non-uniformities. In addition, compensation strategies were implemented to limit R2 deviations caused by temperature drift during scanning. Inter- and intra-slice R2 deviations in the phantom were thereby significantly reduced. This was verified in an investigative study where the same phantom was irradiated with two rectangular superimposed beams: structural deviations between gel measurements and computational results remained below 3% outside high dose gradient regions; the spatial shift in those regions was within 2.5 mm. When comparing gel measurements with computational results for the IMAT treatment, dose deviations were noted in the liver and right kidney, but the dose-volume constraints were met. Root-mean-square differences between both dose distributions were within 5% with spatial deviations not more than 2.5 mm. Dose fluctuations due to gantry angle discretization in the dose computation algorithm were particularly noticeable in the low-dose region

  17. 137Cs source dose distribution using the Fricke Xylenol Gel dosimetry

    International Nuclear Information System (INIS)

    Sato, R.; De Almeida, A.; Moreira, M.V.

    2009-01-01

    Dosimetric measurements close to radioisotope sources, such as those used in brachytherapy, require high spatial resolution to avoid incorrect results in the steep dose gradient region. In this work the Fricke Xylenol Gel dosimeter was used to obtain the spatial dose distribution. The readings from a 137 Cs source were performed using two methods, visible spectrophotometer and CCD camera images. Good agreement with the Sievert summation method was found for the transversal axis dose profile within uncertainties of 4% and 5%, for the spectrophotometer and CCD camera respectively. Our results show that the dosimeter is adequate for brachytherapy dosimetry and, owing to its relatively fast and easy preparation and reading, it is recommended for quality control in brachytherapy applications.

  18. A fast dual wavelength laser beam fluid-less optical CT scanner for radiotherapy 3D gel dosimetry I: design and development

    Science.gov (United States)

    Ramm, Daniel

    2018-02-01

    Three dimensional dosimetry by optical CT readout of radiosensitive gels or solids has previously been indicated as a solution for measurement of radiotherapy 3D dose distributions. The clinical uptake of these dosimetry methods has been limited, partly due to impracticalities of the optical readout such as the expertise and labour required for refractive index fluid matching. In this work a fast laser beam optical CT scanner is described, featuring fluid-less and dual wavelength operation. A second laser with a different wavelength is used to provide an alternative reference scan to the commonly used pre-irradiation scan. Transmission data for both wavelengths is effectively acquired simultaneously, giving a single scan process. Together with the elimination of refractive index fluid matching issues, scanning practicality is substantially improved. Image quality and quantitative accuracy were assessed for both dual and single wavelength methods. The dual wavelength scan technique gave improvements in uniformity of reconstructed optical attenuation coefficients in the sample 3D volume. This was due to a reduction of artefacts caused by scan to scan changes. Optical attenuation measurement accuracy was similar for both dual and single wavelength modes of operation. These results established the basis for further work on dosimetric performance.

  19. Reviewing three dimensional dosimetry: basics and utilization as presented over 17 Years of DosGel and IC3Ddose

    International Nuclear Information System (INIS)

    Schreiner, L J

    2017-01-01

    For seventeen years a community of basic and clinical scientists and researchers has been meeting bi-annually to promote the clinical advance of techniques to measure radiation dose in three dimensions. The interest in this dosimetry was motivated by its promise as an effective methodology for 3D measurement of the complex conformal dose distributions achieved by modern techniques such as Intensity Modulated and Volumetric Arc Radiation Therapy. Each of the International Conferences on 3D Radiation Dosimetry resulted in the publication of informative proceedings [1-8], the majority openly available on the internet. The proceedings included papers that: i) reviewed the basic science of the radiation sensitive materials used to accumulate the dose information, ii) introduced the science and engineering of the imaging systems required to read the information out, iii) described the work flows and systems required for efficient dosimetry, iv) reported the protocols required for reproducible dosimetry, and v) showed examples of clinical use illustrating advantage and limitations of the dosimetry. This paper is intended to use the framework provided by these proceedings to review the current 3D chemical dosimeters available and to discuss the requirements for their use. The paper describes how 3D dosimetry can complement other dose delivery validation approaches available in the clinic. It closes with some personal reflections of how the motivation for, and practice of, 3D dosimetry have changed (or not) over the years. (paper)

  20. Reviewing three dimensional dosimetry: basics and utilization as presented over 17 Years of DosGel and IC3Ddose

    Science.gov (United States)

    Schreiner, L. J.

    2017-05-01

    For seventeen years a community of basic and clinical scientists and researchers has been meeting bi-annually to promote the clinical advance of techniques to measure radiation dose in three dimensions. The interest in this dosimetry was motivated by its promise as an effective methodology for 3D measurement of the complex conformal dose distributions achieved by modern techniques such as Intensity Modulated and Volumetric Arc Radiation Therapy. Each of the International Conferences on 3D Radiation Dosimetry resulted in the publication of informative proceedings [1-8], the majority openly available on the internet. The proceedings included papers that: i) reviewed the basic science of the radiation sensitive materials used to accumulate the dose information, ii) introduced the science and engineering of the imaging systems required to read the information out, iii) described the work flows and systems required for efficient dosimetry, iv) reported the protocols required for reproducible dosimetry, and v) showed examples of clinical use illustrating advantage and limitations of the dosimetry. This paper is intended to use the framework provided by these proceedings to review the current 3D chemical dosimeters available and to discuss the requirements for their use. The paper describes how 3D dosimetry can complement other dose delivery validation approaches available in the clinic. It closes with some personal reflections of how the motivation for, and practice of, 3D dosimetry have changed (or not) over the years.

  1. Performance evaluation of an improved optical computed tomography polymer gel dosimeter system for 3D dose verification of static and dynamic phantom deliveries

    International Nuclear Information System (INIS)

    Lopatiuk-Tirpak, O.; Langen, K. M.; Meeks, S. L.; Kupelian, P. A.; Zeidan, O. A.; Maryanski, M. J.

    2008-01-01

    The performance of a next-generation optical computed tomography scanner (OCTOPUS-5X) is characterized in the context of three-dimensional gel dosimetry. Large-volume (2.2 L), muscle-equivalent, radiation-sensitive polymer gel dosimeters (BANG-3) were used. Improvements in scanner design leading to shorter acquisition times are discussed. The spatial resolution, detectable absorbance range, and reproducibility are assessed. An efficient method for calibrating gel dosimeters using the depth-dose relationship is applied, with photon- and electron-based deliveries yielding equivalent results. A procedure involving a preirradiation scan was used to reduce the edge artifacts in reconstructed images, thereby increasing the useful cross-sectional area of the dosimeter by nearly a factor of 2. Dose distributions derived from optical density measurements using the calibration coefficient show good agreement with the treatment planning system simulations and radiographic film measurements. The feasibility of use for motion (four-dimensional) dosimetry is demonstrated on an example comparing dose distributions from static and dynamic delivery of a single-field photon plan. The capability to visualize three-dimensional dose distributions is also illustrated

  2. Preliminary investigation of PAGAT polymer gel radionuclide dosimetry of Tc-99m

    Science.gov (United States)

    Braun, Kelly; Bailey, Dale; Hill, Brendan; Baldock, Clive

    2009-05-01

    PAGAT polymer gel was investigated as a suitable dosimeter materials for measuring absorbed dose from the unsealed source radionuclide Tc-99m. Differing amounts of Tc-99m over the range of 25-5000 MBq were introduced into a normoxic polymer gel mixture (PAGAT) in sealed nitrogen-filled P6 glass vials. After irradiation the gels were evaluated using MRI more than 48 hours after preparation to allow for radioactive decay. The dose delivered to the vial was also calculated empirically. R2 versus total activity curves were obtained over a number of experiments and these were used to evaluate the relationship between the amount of gel polymerization and the dose deposited by the radionuclide. A linear response up to 1000 MBq (corresponding to 20Gy) was displayed and was still behaving monotonically at 5000 MBq. Polymer gels offer the potential to measure radiation dose three-dimensionally using MRI.

  3. Analysis of Two-Dimensional Electrophoresis Gel Images

    DEFF Research Database (Denmark)

    Pedersen, Lars

    2002-01-01

    This thesis describes and proposes solutions to some of the currently most important problems in pattern recognition and image analysis of two-dimensional gel electrophoresis (2DGE) images. 2DGE is the leading technique to separate individual proteins in biological samples with many biological...

  4. Two-dimensional polyacrylamide gel electrophoresis of intracellular proteins

    International Nuclear Information System (INIS)

    Ojima, N.; Sakamoto, T.; Yamashita, M.

    1996-01-01

    Since two-dimensional electrophoresis was established by O'Farrell for analysis of intracellular proteins of Escherichia coli, it has been applied to separation of proteins of animal cells and tissues, and especially to identification of stress proteins. Using this technique, proteins are separated by isoelectric focusing containing 8 m urea in the first dimension and by SDS-PAGE in the second dimension. The gels are stained with Coomassie Blue R-250 dye, followed by silver staining. In the case of radio-labeled proteins, the gels are dried and then autoradiographed. In order to identify a specific protein separated by two-dimensional electrophoresis, a technique determining the N-terminal amino acid sequence of the protein has been developed recently. After the proteins in the gel were electrotransferred to a polyvinylidene difluoride membrane, the membrane was stained for protein with Commassie Blue and a stained membrane fragment was applied to a protein sequencer. Our recent studies demonstrated that fish cells newly synthesized various proteins in response to heat shock, cold nd osmotic stresses. For example, when cellular proteins extracted from cold-treated rainbow trout cells were subjected to two-dimensional gel electrophoresis, the 70 kDa protein was found to be synthesized during the cold-treatment. N-Terminal sequence analysis showed that the cold-inducible protein was a homolog of mammalian valosin-containing protein and yeast cell division cycle gene product CDC48p. Furthermore, the sequence data were useful for preparing PCR primers and a rabbit antibody against a synthetic peptide to analyze a role for the protein in the function of trout cells and mechanisms for regulation

  5. Two-dimensional polyacrylamide gel analysis of Plodia interpunctella granulosis virus

    International Nuclear Information System (INIS)

    Russell, D.L.; Consigli, R.A.

    1986-01-01

    The structural polypeptides of purified Plodia interpunctella granulosis virus were analyzed by three different two-dimensional gel systems. Isoelectric focusing followed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis allowed resolution of 53 acidic polypeptides in the enveloped nucleocapsid of the virus ranging in molecular weight from 97,300 to 8000. Nine of these polypeptides were shown to be glycoproteins by the technique of radiolabeled lectin blotting. Separation of the granulin in this system allowed resolution of five species, all of which have identical tryptic peptide maps. This matrix protein was demonstrated to be a phosphoglycoprotein by radiolabeled lectin blotting and acid phosphatase dephosphorylation. Nonequilibrium pH gel electrophoresis followed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis allowed resolution of the major basic protein of the virus, VP12, from a more acidic protein of the same molecular weight. Tryptic peptide analysis demonstrated that these two proteins were indeed different and acid urea gels followed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis allowed localization of the acidic protein to the envelope and the basic protein to the nucleocapsid of the virus. Finally, probing of the separated envelope nucleocapsid proteins in both the isoelectric focusing and nonequilibrium pH gel electrophoresis two-dimensional systems after transfer to nitrocellulose with iodinated, purified viral proteins allowed further insight into reactions which may be important in the maintenance of the virion structure

  6. Fricke gel-layer dosimetry in HDR brachytherapy

    International Nuclear Information System (INIS)

    Gambarini, G.; Negri, A.; Carrara, M.; Marchesini, R.

    2008-01-01

    Full text: In the last decade, technological improvements in radiotherapy have been significant and consequently the use and importance of radiotherapy in cancer treatment have increased greatly. In brachytherapy, new possibilities have been opened by the impressive progresses in 3D imaging, by the development of sophisticated techniques for modern afterloaders and by the constantly increasing speed and capacity of computers. However, these methodological improvements require corresponding improvements in the dosimetry methods, in order to ensure that the values calculated with computer treatment planning systems, adopted in the clinical praxis, agree with the delivered dose distributions. Fricke gel-layer dosimeters (FGLD) are under study by our group as a reliable alternative to films, semiconductors arrays or thermoluminescent dosimeters (TLDs). In the last years, we have significantly improved this technique by defining the FGLD best chemical composition, by optimizing the image acquisition assessment and by developing a dedicated software for image analysis. In this study, experimental measurements of planar dose distributions of a clinical 192 Ir source (Microselectron HDR, Nucletron) obtained by irradiating a series of piled-up FGL dosimeters in a tissue-equivalent phantom are presented. The obtained results were in accordance to TLD measurements and to treatment planning system (Plato, Nucletron) calculations. FGLD have proven to be a reliable tool to achieve HDR brachytherapy dose distribution measurements

  7. Electron beam dosimetry in heterogeneous phantoms using a MAGIC normoxic polymer gel

    International Nuclear Information System (INIS)

    Ghahraman Asl, R.; Nedaie, H.; Bolouri, B.; Arbabi, A.

    2010-01-01

    Nowadays radiosensitive polymer gels are used as a reliable dosimetry tool for verification of 3D dose distributions. Special characteristics of these dosimeters have made them useful for verification of complex dose distributions in clinical situations. The aim of this work was to evaluate the capability of a normoxic polymer gel to determine electron dose distributions in different slab phantoms in presence of small heterogeneities. Materials and Methods: Different cylindrical phantoms consisting gel were used under slab phantoms during each irradiation. MR images of irradiated gel phantoms were obtained to determine their R2 relaxation maps. 1D and 2D lateral dose profiles were acquired at depths of 1 cm for an 8 MeV beam and 1 and 4 cm for the 15 MeV energy, and then compared with the lateral dose profiles measured using a diode detector. In addition, 3D dose distributions around these heterogeneities for the same energies and depths were measured using a gel dosimeter. Results: Dose resolution for MR gel images at the range of 0-10 Gy was less than 1.55 Gy. Mean dose difference and distance to agreement for dose profiles were 2.6% and 2.2 mm, respectively. The results of the MAGIC-type polymer gel for bone heterogeneity at 8 MeV showed a reduction in dose of approximately 50%, and 30% and 10% at depths 1 and 4 cm at 15 MeV. However, for air heterogeneity increases in dose of approximately 50% at depth 1 cm under the heterogeneity at 8 MeV and 20% and 45% respectively at 15 MeV were observed. Discussion and Conclusion: Generally, electron beam distributions are significantly altered in the presence of tissue inhomogeneities such as bone and air cavities, this being related to mass stopping and mass scattering powers of heterogeneous materials. At the same time, hot and cold scatter lobes under heterogeneity regions due to scatter edge effects were also seen. However, these effects (increased dose, reduced dose, hot and cold spots) at deeper depths, are

  8. An Investigation of the Dose Distribution from LDR Ir-192 Wires in the Triangular Implants of the Paris System using Polymer Gel Dosimetry

    Directory of Open Access Journals (Sweden)

    Azizollah Rahimi

    2010-12-01

    Full Text Available Introduction: Polymer gels are modern dosimeters providing three dimensional dose distributions. These dosimeters can be used in brachytherapy in which the tumor dimension is relatively small and the dose gradient is high. In this study, the ability of the MAGICA polymer gel was investigated for assessing the absolute dose values as well as the dose distribution of low dose rate (LDR Ir-192 wires in interstitial brachytherapy based in triangular implants of the Paris system. Material and Methods: A suitable phantom was made from Perspex. Glass tubes were used as the external tubes for holding the Ir-192 wires in the phantom. The MAGICA polymer gel was made and placed in the phantom. The phantom and the calibration tubes were irradiated using LDR Ir-192 wires and a Co-60 teletherapy unit respectively. They were subsequently imaged using an MRI scanner. The R2 (=1/T2 maps were extracted from several sequential T2-weighted MRI images. The dose values resulting from the polymer gel measurements at the reference points were compared with those from the common calculation method at the same points. In addition, the isodose curves resulting from gel dosimetry were compared with those from a brachytherapy treatment planning system (Flexiplan. Results: The average of the dose values measured with the gel at the reference points was 62.75% higher than those calculated at the same points. Investigating the isodose curves revealed that the maximum distance to agreement (DTAmax between the isodoses resulting from the gel and those obtained from the treatment planning system was less than 3 mm at different dose levels. Discussion and Conclusion: Although the MAGICA gel indicates a higher absolute dose value than those calculated commonly, it can give the relative dose values accurately. Therefore, it can be recommended to be used for the assessment of dose distributions for the treatment of tissues as well as quality control of the treatment planning systems.

  9. Effects of gel composition on the radiation induced density change in PAG polymer gel dosimeters: a model and experimental investigations

    International Nuclear Information System (INIS)

    Hilts, M; Jirasek, A; Duzenli, C

    2004-01-01

    Due to a density change that occurs in irradiated polyacrylamide gel (PAG), x-ray computed tomography (CT) has emerged as a feasible method of performing polymer gel dosimetry. However, applicability of the technique is currently limited by low sensitivity of the density change to dose. This work investigates the effect of PAG composition on the radiation induced density change and provides direction for future work in improving the sensitivity of CT polymer gel dosimetry. A model is developed that describes the PAG density change (Δρ gel ) as a function of both polymer yield (%P) and an intrinsic density change, per unit polymer yield, that occurs on conversion of monomer to polymer (Δρ polymer ). %P is a function of the fraction of monomer consumed and the weight fraction of monomer in the unirradiated gel (%T). Applying the model to experimental CT and Raman spectroscopic data, two important fundamental properties of the response of PAG density to dose (Δρ gel dose response) are discovered. The first property is that Δρ polymer depends on PAG %C (cross-linking fraction of total monomer) such that low and high %C PAGs exhibit a higher Δρ polymer than do more intermediate %C PAGs. This relationship is opposite to the relationship of polymer yield to %C and is explained by the effect of %C on the type of polymer formed. The second property is that the Δρ gel dose response is linearly dependent on %T. From the model, the inference is that, at least for %T≤12%, monomer consumption and Δρ polymer depend solely on %C. In terms of optimizing CT polymer gel dosimetry for high sensitivity, these results indicate that Δρ polymer can be expected to vary with each polymer gel system and thus should be considered when choosing a polymer gel for CT gel dosimetry. However, Δρ polymer and %P cannot be maximized simultaneously and maximizing %P, by choosing gels with intermediate %C and high %T, is found to have the greatest impact on increasing the

  10. Ocular Proteomics with Emphasis on Two-Dimensional Gel Electrophoresis and Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Honoré Bent

    2010-01-01

    Full Text Available Abstract The intention of this review is to provide an overview of current methodologies employed in the rapidly developing field of ocular proteomics with emphasis on sample preparation, two-dimensional polyacrylamide gel electrophoresis (2D-PAGE and mass spectrometry (MS. Appropriate sample preparation for the diverse range of cells and tissues of the eye is essential to ensure reliable results. Current methods of protein staining for 2D-PAGE, protein labelling for two-dimensional difference gel electrophoresis, gel-based expression analysis and protein identification by MS are summarised. The uses of gel-free MS-based strategies (MuDPIT, iTRAQ, ICAT and SILAC are also discussed. Proteomic technologies promise to shed new light onto ocular disease processes that could lead to the discovery of strong novel biomarkers and therapeutic targets useful in many ophthalmic conditions.

  11. Fluctuations and symmetries in two-dimensional active gels.

    Science.gov (United States)

    Sarkar, N; Basu, A

    2011-04-01

    Motivated by the unique physical properties of biological active matter, e.g., cytoskeletal dynamics in eukaryotic cells, we set up effective two-dimensional (2d) coarse-grained hydrodynamic equations for the dynamics of thin active gels with polar or nematic symmetries. We use the well-known three-dimensional (3d) descriptions (K. Kruse et al., Eur. Phys. J. E 16, 5 (2005); A. Basu et al., Eur. Phys. J. E 27, 149 (2008)) for thin active-gel samples confined between parallel plates with appropriate boundary conditions to derive the effective 2d constitutive relations between appropriate thermodynamic fluxes and generalised forces for small deviations from equilibrium. We consider three distinct cases, characterised by spatial symmetries and boundary conditions, and show how such considerations dictate the structure of the constitutive relations. We use these to study the linear instabilities, calculate the correlation functions and the diffusion constant of a small tagged particle, and elucidate their dependences on the activity or nonequilibrium drive.

  12. Investigation of the dose rate dependency of the PAGAT gel dosimeter at low dose rates

    International Nuclear Information System (INIS)

    Zehtabian, M.; Faghihi, R.; Zahmatkesh, M.H.; Meigooni, A.S.; Mosleh-Shirazi, M.A.; Mehdizadeh, S.; Sina, S.; Bagheri, S.

    2012-01-01

    Medical physicists need dosimeters such as gel dosimeters capable of determining three-dimensional dose distributions with high spatial resolution. To date, in combination with magnetic resonance imaging (MRI), polyacrylamide gel (PAG) polymers are the most promising gel dosimetry systems. The purpose of this work was to investigate the dose rate dependency of the PAGAT gel dosimeter at low dose rates. The gel dosimeter was used for measurement of the dose distribution around a Cs-137 source from a brachytherapy LDR source to have a range of dose rates from 0.97 Gy h −1 to 0.06 Gy h −1 . After irradiation of the PAGAT gel, it was observed that the dose measured by gel dosimetry was almost the same at different distances (different dose rates) from the source, although the points nearer the source had been expected to receive greater doses. Therefore, it was suspected that the PAGAT gel is dose rate dependent at low dose rates. To test this further, three other sets of measurements were performed by placing vials containing gel at different distances from a Cs-137 source. In the first two measurements, several plastic vials were exposed to equal doses at different dose rates. An ionization chamber was used to measure the dose rate at each distance. In addition, three TLD chips were simultaneously irradiated in order to verify the dose to each vial. In the third measurement, to test the oxygen diffusion through plastic vials, the experiment was repeated again using plastic vials in a nitrogen box and glass vials. The study indicates that oxygen diffusion through plastic vials for dose rates lower than 2 Gy h −1 would affect the gel dosimeter response and it is suggested that the plastic vials or (phantoms) in an oxygen free environment or glass vials should be used for the dosimetry of low dose rate sources using PAGAT gel to avoid oxygen diffusion through the vials.

  13. Multi-dimensional fiber-optic radiation sensor for ocular proton therapy dosimetry

    International Nuclear Information System (INIS)

    Jang, K.W.; Yoo, W.J.; Moon, J.; Han, K.T.; Park, B.G.; Shin, D.; Park, S-Y.; Lee, B.

    2012-01-01

    In this study, we fabricated a multi-dimensional fiber-optic radiation sensor, which consists of organic scintillators, plastic optical fibers and a water phantom with a polymethyl methacrylate structure for the ocular proton therapy dosimetry. For the purpose of sensor characterization, we measured the spread out Bragg-peak of 120 MeV proton beam using a one-dimensional sensor array, which has 30 fiber-optic radiation sensors with a 1.5 mm interval. A uniform region of spread out Bragg-peak using the one-dimensional fiber-optic radiation sensor was obtained from 20 to 25 mm depth of a phantom. In addition, the Bragg-peak of 109 MeV proton beam was measured at the depth of 11.5 mm of a phantom using a two-dimensional sensor array, which has 10×3 sensor array with a 0.5 mm interval.

  14. A practical three-dimensional dosimetry system for radiation therapy

    International Nuclear Information System (INIS)

    Guo Pengyi; Adamovics, John; Oldham, Mark

    2006-01-01

    There is a pressing need for a practical three-dimensional (3D) dosimetry system, convenient for clinical use, and with the accuracy and resolution to enable comprehensive verification of the complex dose distributions typical of modern radiation therapy. Here we introduce a dosimetry system that can achieve this challenge, consisting of a radiochromic dosimeter (PRESAGE trade mark sign ) and a commercial optical computed tomography (CT) scanning system (OCTOPUS trade mark sign ). PRESAGE trade mark sign is a transparent material with compelling properties for dosimetry, including insensitivity of the dose response to atmospheric exposure, a solid texture negating the need for an external container (reducing edge effects), and amenability to accurate optical CT scanning due to radiochromic optical contrast as opposed to light-scattering contrast. An evaluation of the performance and viability of the PRESAGE trade mark sign /OCTOPUS, combination for routine clinical 3D dosimetry is presented. The performance of the two components (scanner and dosimeter) was investigated separately prior to full system test. The optical CT scanner has a spatial resolution of ≤1 mm, geometric accuracy within 1 mm, and high reconstruction linearity (with a R 2 value of 0.9979 and a standard error of estimation of ∼1%) relative to independent measurement. The overall performance of the PRESAGE trade mark sign /OCTOPUS system was evaluated with respect to a simple known 3D dose distribution, by comparison with GAFCHROMIC[reg] EBT film and the calculated dose from a commissioned planning system. The 'measured' dose distribution in a cylindrical PRESAGE trade mark sign dosimeter (16 cm diameter and 11 cm height) was determined by optical-CT, using a filtered backprojection reconstruction algorithm. A three-way Gamma map comparison (4% dose difference and 4 mm distance to agreement), between the PRESAGE trade mark sign , EBT and calculated dose distributions, showed full agreement in

  15. Improving calibration accuracy in gel dosimetry

    International Nuclear Information System (INIS)

    Oldham, M.; McJury, M.; Webb, S.; Baustert, I.B.; Leach, M.O.

    1998-01-01

    A new method of calibrating gel dosimeters (applicable to both Fricke and polyacrylamide gels) is presented which has intrinsically higher accuracy than current methods, and requires less gel. Two test-tubes of gel (inner diameter 2.5 cm, length 20 cm) are irradiated separately with a 10x10cm 2 field end-on in a water bath, such that the characteristic depth-dose curve is recorded in the gel. The calibration is then determined by fitting the depth-dose measured in water, against the measured change in relaxivity with depth in the gel. Increased accuracy is achieved in this simple depth-dose geometry by averaging the relaxivity at each depth. A large number of calibration data points, each with relatively high accuracy, are obtained. Calibration data over the full range of dose (1.6-10 Gy) is obtained by irradiating one test-tube to 10 Gy at dose maximum (D max ), and the other to 4.5 Gy at D max . The new calibration method is compared with a 'standard method' where five identical test-tubes of gel were irradiated to different known doses between 2 and 10 Gy. The percentage uncertainties in the slope and intercept of the calibration fit are found to be lower with the new method by a factor of about 4 and 10 respectively, when compared with the standard method and with published values. The gel was found to respond linearly within the error bars up to doses of 7 Gy, with a slope of 0.233±0.001 s -1 Gy -1 and an intercept of 1.106±0.005 Gy. For higher doses, nonlinear behaviour was observed. (author)

  16. Review of Fricke gel dosimeters

    International Nuclear Information System (INIS)

    Schreiner, L J

    2004-01-01

    The innovation of adding a gel matrix to the traditional Fricke dosimeter to stabilize geometric information established the field of gel dosimetry for radiation therapy. A discussion of Fricke gels provides an overview of the issues that determine the dose response of all gel dosimeters in general. In this paper we review some of the features of Fricke systems to illustrate these issues and, in addition, to motivate renewed clinical interest in Fricke gels

  17. MO-B-BRB-03: 3D Dosimetry in the Clinic: Validating Special Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Juang, T. [Stanford Cancer Center (United States)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  18. MO-B-BRB-01: 3D Dosimetry in the Clinic: Background and Motivation

    Energy Technology Data Exchange (ETDEWEB)

    Schreiner, L. [Cancer Center of Southeastern Ontario (Canada)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  19. MO-B-BRB-01: 3D Dosimetry in the Clinic: Background and Motivation

    International Nuclear Information System (INIS)

    Schreiner, L.

    2016-01-01

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  20. MO-B-BRB-03: 3D Dosimetry in the Clinic: Validating Special Techniques

    International Nuclear Information System (INIS)

    Juang, T.

    2016-01-01

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  1. Two-dimensional gel electrophoresis analysis of different parts of ...

    African Journals Online (AJOL)

    Two-dimensional gel electrophoresis analysis of different parts of Panax quinquefolius L. root. ... From these results it was concluded that proteomic analysis method was an effective way to identify the different parts of quinquefolius L. root. These findings may contribute to further understanding of the physiological ...

  2. Optical computed tomography in PRESAGE® three-dimensional dosimetry: Challenges and prospective.

    Science.gov (United States)

    Khezerloo, Davood; Nedaie, Hassan Ali; Farhood, Bagher; Zirak, Alireza; Takavar, Abbas; Banaee, Nooshin; Ahmadalidokht, Isa; Kron, Tomas

    2017-01-01

    With the advent of new complex but precise radiotherapy techniques, the demands for an accurate, feasible three-dimensional (3D) dosimetry system have been increased. A 3D dosimeter system generally should not only have accurate and precise results but should also feasible, inexpensive, and time consuming. Recently, one of the new candidates for 3D dosimetry is optical computed tomography (CT) with a radiochromic dosimeter such as PRESAGE®. Several generations of optical CT have been developed since the 90s. At the same time, a large attempt has been also done to introduce the robust dosimeters that compatible with optical CT scanners. In 2004, PRESAGE® dosimeter as a new radiochromic solid plastic dosimeters was introduced. In this decade, a large number of efforts have been carried out to enhance optical scanning methods. This article attempts to review and reflect on the results of these investigations.

  3. Optical computed tomography in PRESAGE® three-dimensional dosimetry: Challenges and prospective

    Directory of Open Access Journals (Sweden)

    Davood Khezerloo

    2017-01-01

    Full Text Available With the advent of new complex but precise radiotherapy techniques, the demands for an accurate, feasible three-dimensional (3D dosimetry system have been increased. A 3D dosimeter system generally should not only have accurate and precise results but should also feasible, inexpensive, and time consuming. Recently, one of the new candidates for 3D dosimetry is optical computed tomography (CT with a radiochromic dosimeter such as PRESAGE®. Several generations of optical CT have been developed since the 90s. At the same time, a large attempt has been also done to introduce the robust dosimeters that compatible with optical CT scanners. In 2004, PRESAGE® dosimeter as a new radiochromic solid plastic dosimeters was introduced. In this decade, a large number of efforts have been carried out to enhance optical scanning methods. This article attempts to review and reflect on the results of these investigations.

  4. Development a high-resolution radiation dosimetry system based on Fricke solutions

    Energy Technology Data Exchange (ETDEWEB)

    Vedelago, J. [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina); Mattea, F. [Universidad Nacional de Cordoba, Facultad de Ciencias Quimicas, Departamento de Quimica Organica, Ciudad Universitaria, 5000 Cordoba (Argentina); Valente, M., E-mail: josevedelago@gmail.com [Instituto de Fisica E. Gaviola, Oficina 102 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Due to the growing complexity of modern medical procedures involving the use of ionizing radiation, dosimetry by non-conventional techniques is one of the research areas in the field of greatest interest nowadays. Tissue-equivalent high-resolution dosimetry systems capable of attaining continuous dose mapping are required. In this scenario, Fricke gel dosimetry is a very promising option for in-phantom dose measurements in complex radiation techniques. Implementation of this technique requires dedicated instruments capable of measuring and performing the immediate in situ analysis of the acquired data at the radiation facility. The versatility of Fricke gel dosimetry in different applications depending on the chemical and isotopic composition of the dosimeter extends its application to different high performance conventional and non-conventional radiation procedures involving diverse types of radiation treatments and also radiation diagnosis procedures. This work presents an integral dosimetry system, based on Fricke gel solutions and their analysis by optical techniques, aiming for an increase in the precision on dose determinations. The chemical synthesis and dosimeter preparation were accomplished at LIIFAMIRx facilities, following the procedures and protocols described in previous works. Additionally, specific instrumentation for optical sample analysis was completely designed and constructed at LIIFAMIRx facilities. The main outcome of this work was the development of a methodology that improves the integral dose determination performance by the pre-irradiation of Fricke gel dosimeters. (author)

  5. Development a high-resolution radiation dosimetry system based on Fricke solutions

    International Nuclear Information System (INIS)

    Vedelago, J.; Mattea, F.; Valente, M.

    2014-08-01

    Due to the growing complexity of modern medical procedures involving the use of ionizing radiation, dosimetry by non-conventional techniques is one of the research areas in the field of greatest interest nowadays. Tissue-equivalent high-resolution dosimetry systems capable of attaining continuous dose mapping are required. In this scenario, Fricke gel dosimetry is a very promising option for in-phantom dose measurements in complex radiation techniques. Implementation of this technique requires dedicated instruments capable of measuring and performing the immediate in situ analysis of the acquired data at the radiation facility. The versatility of Fricke gel dosimetry in different applications depending on the chemical and isotopic composition of the dosimeter extends its application to different high performance conventional and non-conventional radiation procedures involving diverse types of radiation treatments and also radiation diagnosis procedures. This work presents an integral dosimetry system, based on Fricke gel solutions and their analysis by optical techniques, aiming for an increase in the precision on dose determinations. The chemical synthesis and dosimeter preparation were accomplished at LIIFAMIRx facilities, following the procedures and protocols described in previous works. Additionally, specific instrumentation for optical sample analysis was completely designed and constructed at LIIFAMIRx facilities. The main outcome of this work was the development of a methodology that improves the integral dose determination performance by the pre-irradiation of Fricke gel dosimeters. (author)

  6. 3D dose imaging for arc therapy techniques by means of Fricke gel dosimetry and dedicated Monte Carlo simulations

    International Nuclear Information System (INIS)

    Valente, Mauro; Castellano, Gustavo; Sosa, Carlos

    2008-01-01

    Full text: Radiotherapy is one of the most effective techniques for tumour treatment and control. During the last years, significant developments were performed regarding both irradiation technology and techniques. However, accurate 3D dosimetric techniques are nowadays not commercially available. Due to their intrinsic characteristics, traditional dosimetric techniques like ionisation chamber, film dosimetry or TLD do not offer proper continuous 3D dose mapping. The possibility of using ferrous sulphate (Fricke) dosimeters suitably fixed to a gel matrix, along with dedicated optical analysis methods, based on light transmission measurements for 3D absorbed dose imaging in tissue-equivalent materials, has become great interest in radiotherapy. Since Gore et al. showed in 1984 that the oxidation of ferrous ions to ferric ions still happen even when fixing the ferrous sulphate solution to a gelatine matrix, important efforts have been dedicated in developing and improving real continuous 3D dosimetric systems based on Fricke solution. The purpose of this work is to investigate the capability and suitability of Fricke gel dosimetry for arc therapy irradiations. The dosimetric system is mainly composed by Fricke gel dosimeters, suitably shaped in form of thin layers and optically analysed by means of visible light transmission measurements, acquiring sample images just before and after irradiation by means of a commercial flatbed-like scanner. Image acquisition, conversion to matrices and further analysis are accomplished by means of dedicated developed software, which includes suitable algorithms for optical density differences calculation and corresponding absorbed dose conversion. Dedicated subroutines allow 3D dose imaging reconstruction from single layer information, by means of computer tomography-like algorithms. Also, dedicated Monte Carlo (PENELOPE) subroutines have been adapted in order to achieve accurate simulation of arc therapy irradiation techniques

  7. MO-B-BRB-02: 3D Dosimetry in the Clinic: IMRT Technique Validation in Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Ceberg, S. [Lund University (Sweden)

    2016-06-15

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  8. MO-B-BRB-02: 3D Dosimetry in the Clinic: IMRT Technique Validation in Sweden

    International Nuclear Information System (INIS)

    Ceberg, S.

    2016-01-01

    Full three-dimensional (3D) dosimetry using volumetric chemical dosimeters probed by 3D imaging systems has long been a promising technique for the radiation therapy clinic, since it provides a unique methodology for dose measurements in the volume irradiated using complex conformal delivery techniques such as IMRT and VMAT. To date true 3D dosimetry is still not widely practiced in the community; it has been confined to centres of specialized expertise especially for quality assurance or commissioning roles where other dosimetry techniques are difficult to implement. The potential for improved clinical applicability has been advanced considerably in the last decade by the development of improved 3D dosimeters (e.g., radiochromic plastics, radiochromic gel dosimeters and normoxic polymer gel systems) and by improved readout protocols using optical computed tomography or magnetic resonance imaging. In this session, established users of some current 3D chemical dosimeters will briefly review the current status of 3D dosimetry, describe several dosimeters and their appropriate imaging for dose readout, present workflow procedures required for good dosimetry, and analyze some limitations for applications in select settings. We will review the application of 3D dosimetry to various clinical situations describing how 3D approaches can complement other dose delivery validation approaches already available in the clinic. The applications presented will be selected to inform attendees of the unique features provided by full 3D techniques. Learning Objectives: L. John Schreiner: Background and Motivation Understand recent developments enabling clinically practical 3D dosimetry, Appreciate 3D dosimetry workflow and dosimetry procedures, and Observe select examples from the clinic. Sofie Ceberg: Application to dynamic radiotherapy Observe full dosimetry under dynamic radiotherapy during respiratory motion, and Understand how the measurement of high resolution dose data in an

  9. X-ray computer tomography, ultrasound and vibrational spectroscopic evaluation techniques of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Baldock, Clive

    2004-01-01

    Since Gore et al published their paper on Fricke gel dosimetry, the predominant method of evaluation of both Fricke and polymer gel dosimeters has been magnetic resonance imaging (MRI). More recently optical computer tomography (CT) has also been a favourable evaluation method. Other techniques have been explored and developed as potential evaluation techniques in gel dosimetry. This paper reviews these other developments

  10. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry

    International Nuclear Information System (INIS)

    MacDougall, N.D.; Pitchford, W.G.; Smith, M.A.

    2002-01-01

    The purpose of this work is to undertake a critical appraisal of the evidence in the published literature concerning the basic parameters of accuracy and precision associated with the use of Fricke and polymer gels (in conjunction with MR imaging) as radiation dosimeters in photon radiotherapy, condensing and analysing the body of published information (to the end of April 2002). A systematic review was undertaken addressing specific issues of precision and accuracy asking defined questions of the published literature. Accuracy and precision in relation to gel dosimetry were defined. Information was obtained from published, peer-reviewed journals. A defined search strategy utilizing MeSH headings and keywords, with extensive use of cross-referencing, identified 115 references dealing with gel dosimetry. Exclusion criteria were used to select only data from publications which would give unequivocal evidence. For accuracy, results had to be compared with an ionization chamber as gold standard and all gel samples had to be manufactured in the same batch. For precision, in addition to gels being from the same batch, samples must all have been irradiated at the same time and scanned simultaneously (or within a short time frame). Many results were found demonstrating 'dose mapping' examples using gels. However, there were very few publications containing firm evidence of precision and accuracy. There was no evidence which fulfilled our criteria about accuracy or precision using Fricke gels. For polymer gels only one paper was found for accuracy (4% (Low et al 1999 Med. Phys. 26 1542-51)) and precision (1.7% (Baldock et al 1998 Phys. Med. Biol. 43 695-702)); however, both were carried out at only one dose level. If the exclusion criteria were relaxed to include accuracy results comparing gel to a non gold standard dosimeter (e.g. TLD), results give a median accuracy of 10% (range 8-23.5%) for polymer gel (Cosgrove et al 2000 Phys. Med. Biol. 45 1195-210, De Deene et al

  11. Investigation of dose distribution in mixed neutron-gamma field of boron neutron capture therapy using N isopropylacrylamide gel

    Energy Technology Data Exchange (ETDEWEB)

    Bavarmegin, Elham; Sadremomtaz, Alireza [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Khalafi, Hossein; Kasesaz, Yaser [Dept. of Physics, University of Guilan, Rasht (Iran, Islamic Republic of); Khajeali, Azim [Medical Education Research Center, Tabriz (Iran, Islamic Republic of)

    2017-02-15

    Gel dosimeters have unique advantages in comparison with other dosimeters. Until now, these gels have been used in different radiotherapy techniques as a reliable dosimetric tool. Because dose distribution measurement is an important factor for appropriate treatment planning in different radiotherapy techniques, in this study, we evaluated the ability of the N-isopropylacrylamide (NIPAM) polymer gel to record the dose distribution resulting from the mixed neutron-gamma field of boron neutron capture therapy (BNCT). In this regard, a head phantom containing NIPAM gel was irradiated using the Tehran Research Reactor BNCT beam line, and then by a magnetic resonance scanner. Eventually, the R2 maps were obtained in different slices of the phantom by analyzing T2-weighted images. The results show that NIPAM gel has a suitable potential for recording three-dimensional dose distribution in mixed neutron-gamma field dosimetry.

  12. TU-C-BRE-04: 3D Gel Dosimetry Using ViewRay On-Board MR Scanner: A Feasibility Study

    International Nuclear Information System (INIS)

    Zhang, L; Du, D; Green, O; Rodriguez, V; Wooten, H; Xiao, Z; Yang, D; Hu, Y; Li, H

    2014-01-01

    Purpose: MR based 3D gel has been proposed for radiation therapy dosimetry. However, access to MR scanner has been one of the limiting factors for its wide acceptance. Recent commercialization of an on-board MR-IGRT device (ViewRay) may render the availability issue less of a concern. This work reports our attempts to simulate MR based dose measurement accuracy on ViewRay using three different gels. Methods: A spherical BANG gel dosimeter was purchased from MGS Research. Cylindrical MAGIC gel and Fricke gel were fabricated in-house according to published recipes. After irradiation, BANG and MAGIC were imaged using a dual-echo spin echo sequence for T2 measurement on a Philips 1.5T MR scanner, while Fricke gel was imaged using multiple spin echo sequences. Difference between MR measured and TPS calculated dose was defined as noise. The noise power spectrum was calculated and then simulated for the 0.35 T magnetic field associated with ViewRay. The estimated noise was then added to TG-119 test cases to simulate measured dose distributions. Simulated measurements were evaluated against TPS calculated doses using gamma analysis. Results: Given same gel, sequence and coil setup, with a FOV of 180×90×90 mm3, resolution of 3×3×3 mm3, and scanning time of 30 minutes, the simulated measured dose distribution using BANG would have a gamma passing rate greater than 90% (3%/3mm and absolute). With a FOV 180×90×90 mm3, resolution of 4×4×5 mm3, and scanning time of 45 minutes, the simulated measuremened dose distribution would have a gamma passing rate greater than 97%. MAGIC exhibited similar performance while Fricke gel was inferior due to much higher noise. Conclusions: The simulation results demonstrated that it may be feasible to use MAGIC and BANG gels for 3D dose verification using ViewRay low-field on-board MRI scanner

  13. A Robust Identification of the Protein Standard Bands in Two-Dimensional Electrophoresis Gel Images

    Directory of Open Access Journals (Sweden)

    Serackis Artūras

    2017-12-01

    Full Text Available The aim of the investigation presented in this paper was to develop a software-based assistant for the protein analysis workflow. The prior characterization of the unknown protein in two-dimensional electrophoresis gel images is performed according to the molecular weight and isoelectric point of each protein spot estimated from the gel image before further sequence analysis by mass spectrometry. The paper presents a method for automatic and robust identification of the protein standard band in a two-dimensional gel image. In addition, the method introduces the identification of the positions of the markers, prepared by using pre-selected proteins with known molecular mass. The robustness of the method was achieved by using special validation rules in the proposed original algorithms. In addition, a self-organizing map-based decision support algorithm is proposed, which takes Gabor coefficients as image features and searches for the differences in preselected vertical image bars. The experimental investigation proved the good performance of the new algorithms included into the proposed method. The detection of the protein standard markers works without modification of algorithm parameters on two-dimensional gel images obtained by using different staining and destaining procedures, which results in different average levels of intensity in the images.

  14. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    International Nuclear Information System (INIS)

    Han, Su Chul; Park, Seung Woo

    2017-01-01

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom

  15. Dose evaluation of three-dimensional small animal phantom with film dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Han, Su Chul [Div. of Medical Radiation Equipment, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Park, Seung Woo [Radilogcial and Medico-Oncological Sciences, University of Sciences and Technology, Daejeon (Korea, Republic of)

    2017-03-15

    The weight of small animal dosimetry has been continuously increased in pre-clinical studies using radiation in small animals. In this study, three-dimensional(3D) small animal phantom was fabricated using 3D printer which has been continuously used and studied in the various fields. The absorbed dose of 3D animal phantom was evaluated by film dosimetry. Previously, the response of film was obtained from the materials used for production of 3D small animal phantom and compared with the bolus used as the tissue equivalent material in the radiotherapy. When irradiated with gamma rays from 0.5 Gy to 6 Gy, it was confirmed that there was a small difference of less than 1% except 0.5 Gy dose. And when small animal phantom was irradiated with 5 Gy, the difference between the irradiated dose and calculated dose from film was within 2%. Based on this study, it would be possible to increase the reliability of dose in pre-clinical studies using irradiation in small animals by evaluating dose of 3D small animal phantom.

  16. Rapid in vitro labeling procedures for two-dimensional gel fingerprinting

    International Nuclear Information System (INIS)

    Lee, Y.F.; Fowlks, E.R.

    1982-01-01

    Improvements of existing in vitro procedures for labeling RNA radioactively, and modifications of the two-dimensional polyacrylamide gel electrophoresis system for making RNA fingerprints are described. These improvements are (a) inactivation of phosphatase with nitric acid at pH 2.0 eliminated the phenol-cholorform extraction step during 5'-end labeling with polynucleotide kinase and [γ- 32 P]ATP; (b) ZnSO 4 inactivation of R Nase T 1 results in a highly efficient procedure for 3'-end labeling with T4 ligase and [5'- 32 P]pCp; and (c) a rapid 4-min procedure for variable quantity range of 125 I and RNA results in a qualitative and quantitative sample for high-molecular weight RNA fingerprinting. Thus, these in vitro procedures become rapid and reproducible when combined with two-dimensional gel electrophoresis which eliminates simultaneously labeled impurities. Each labeling procedure is compared, using tobacco mosaic virus, Brome mosaic virus, and polio RNA. A series of Ap-rich oligonucleotides was discovered in the inner genome of Brome mosaic Virus RNA-3

  17. [Establishment of two-dimensional differential gel electrophoresis using cerebrospinal fluid from neurocysticercosis patients].

    Science.gov (United States)

    Li, Jing-Yi; Tian, Xiao-Jun; Huang, Yong; Yang, Yan-Jun; Ma, Qiao-Rong; Xue, Yan-Ping

    2008-06-30

    To establish the method of two-dimensional differential gel electrophoresis and obtain high resolution 2D images from cerebrospinal fluid (CSF) of patients with neurocysticercosis. CSF samples were collected from four patients diagnosed as neurocysticercosis clinically and by ELISA, computed tomography (CT) or magnetic resonance imaging (MRI), and from four healthy subjects without neurological disorders. The CSF samples were precipitated with cold acetone, then pooled by equal amount as patients and controls. The internal standard comprised equal amounts of proteins extracted from both groups. Internal standard, and proteins from the two groups were labeled prior to electrophoresis with spectrally resolvable fluorescent dyes, cyanein dye2 (Cy2), Cy3 and Cy5. Sodium dodecylsulfonate polyacrylamide gel chromatography (SDS-PAGE) and two-dimensional differential in-gel electrophoresis (2-D DIGE) of labeled samples were then run. The differential expressed proteins showed in the images of SDS-PAGE and 2-D DIGE gels scanned with 488 nm, 532 nm and 633 nm wavelength laser were analyzed by ImageQuant and DeCyde 5.0 respectively. Spot detection and quantification was performed for the differential in-gel analysis (DIA) module of DeCyder. Biological variation analysis (BVA) module of DeCyder was matched gel 1 and gel 2 images to provide data on differential protein expression levels between the two groups. The ImageQuant result displayed that the CSF protein was compatible with the dye, and the difference of protein amount was revealed by the difference of fluorescence intensity. DIA indicated that there were 896 and 894 protein dots on gel 1 and gel 2 respectively, and 90% of them were matched each other. BVA showed that there were 55 protein spots with different expressional level between neurocysticercosis and control groups. Protein spots with two-fold increase or decrease were 47 and 8 respectively in neurocysticercosis patients compared with healthy controls. The

  18. Extracting information from two-dimensional electrophoresis gels by partial least squares regression

    DEFF Research Database (Denmark)

    Jessen, Flemming; Lametsch, R.; Bendixen, E.

    2002-01-01

    of all proteins/spots in the gels. In the present study it is demonstrated how information can be extracted by multivariate data analysis. The strategy is based on partial least squares regression followed by variable selection to find proteins that individually or in combination with other proteins vary......Two-dimensional gel electrophoresis (2-DE) produces large amounts of data and extraction of relevant information from these data demands a cautious and time consuming process of spot pattern matching between gels. The classical approach of data analysis is to detect protein markers that appear...... or disappear depending on the experimental conditions. Such biomarkers are found by comparing the relative volumes of individual spots in the individual gels. Multivariate statistical analysis and modelling of 2-DE data for comparison and classification is an alternative approach utilising the combination...

  19. Polymer gel dosimeter with AQUAJOINT® as hydrogel matrix

    Science.gov (United States)

    Maeyama, Takuya; Ishida, Yasuhiro; Kudo, Yoshihiro; Fukasaku, Kazuaki; Ishikawa, Kenichi L.; Fukunishi, Nobuhisa

    2018-05-01

    We report a polymer gel dosimeter based on a new gel matrix (AQUAJOINT®) that is a thermo-irreversible hydrogel formed by mixing two types of water-based liquids at room temperature. Normoxic N-vinylpyrrolidone-based polymer gels were prepared with AQUAJOINT® instead of gelatin. This AQUAJOINT®-based gel dosimeter exhibits a 2.5-fold increase in sensitivity over a gelatin-based gel dosimeter and a linear dose-response in the dose range of 0-8 Gy. This gel has heat resistance in a jar and controlled gel properties such as viscoelastic and mechanical characters, which may be useful for deformable polymer gel dosimetry.

  20. Optical-CT scanning of polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Oldham, M [Radiation Oncology Physics, Duke University Medical Center, Duke University, NC (United States)

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data.

  1. Optical-CT scanning of polymer gels

    International Nuclear Information System (INIS)

    Oldham, M

    2004-01-01

    The application of optical-CT scanning to achieve accurate high-resolution 3D dosimetry is a subject of current interest. The purpose of this paper is to provide a brief overview of past research and achievements in optical-CT polymer gel dosimetry, and to review current issues and challenges. The origins of optical-CT imaging of light-scattering polymer gels are reviewed. Techniques to characterize and optimize optical-CT performance are presented. Particular attention is given to studies of artifacts in optical-CT imaging, an important area that has not been well studied to date. The technique of optical-CT simulation by Monte-Carlo modeling is introduced as a tool to explore such artifacts. New simulation studies are presented and compared with experimental data

  2. Overview of 3-year experience with large-scale electronic portal imaging device-based 3-dimensional transit dosimetry

    NARCIS (Netherlands)

    Mijnheer, Ben J.; González, Patrick; Olaciregui-Ruiz, Igor; Rozendaal, Roel A.; van Herk, Marcel; Mans, Anton

    2015-01-01

    To assess the usefulness of electronic portal imaging device (EPID)-based 3-dimensional (3D) transit dosimetry in a radiation therapy department by analyzing a large set of dose verification results. In our institution, routine in vivo dose verification of all treatments is performed by means of 3D

  3. SU-F-BRA-11: An Experimental Commissioning Test of Brachytherapy MBDCA Dosimetry, Based On a Commercial Radiochromic Gel/optical CT System

    Energy Technology Data Exchange (ETDEWEB)

    Pappas, E; Karaiskos, P; Zourari, K; Peppa, V; Papagiannis, P [Medical Physics Laboratory, Medical School, University of Athens (Greece)

    2015-06-15

    Purpose: To implement a 3D dose verification procedure of Model-Based Dose Calculation Algorithms (MBDCAs) for {sup 192}Ir HDR brachytherapy, based on a novel Ferrous Xylenol-orange gel (FXG) and optical CT read-out. Methods: The TruView gel was employed for absolute dosimetry in conjunction with cone-beam optical CT read-out with the VISTA scanner (both from Modus Medical Inc, London, ON, Canada). A multi-catheter skin flap was attached to a cylindrical PETE jar (d=9.6cm, h=16cm) filled with FXG, which served as both the dosimeter and the water equivalent phantom of bounded dimensions. X- ray CT image series of the jar with flap attached was imported to Oncentra Brachy v.4.5. A treatment plan consisting of 8 catheters and 56 dwell positions was generated, and Oncentra-ACE MBDCA as well as TG43 dose results were exported for further evaluation. The irradiation was carried out with a microSelecton v2 source. The FXG dose-response, measured via an electron irradiation of a second dosimeter from the same batch, was linear (R2>0.999) at least up to 12Gy. A MCNP6 input file was prepared from the DICOM-RT plan data using BrachyGuide to facilitate Monte Carlo (MC) simulation dosimetry in the actual experimental geometry. Agreement between experimental (reference) and calculated dose distributions was evaluated using the 3D gamma index (GI) method with criteria (5%-2mm applied locally) determined from uncertainty analysis. Results: The TG-43 GI failed, as expected, in the majority of voxels away from the flap (pass rate 59% for D>0.8Gy, corresponding to 10% of prescribed dose). ACE performed significantly better (corresponding pass rate 92%). The GI evaluation for the MC data (corresponding pass rate 97%) failed mainly at low dose points of increased uncertainty. Conclusion: FXG gel/optical CT is an efficient method for level-2 commissioning of brachytherapy MBDCAs. Target dosimetry is not affected from uncertainty introduced by TG43 assumptions in 192Ir skin brachytherapy

  4. Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of bang polymer gel dosimeters

    International Nuclear Information System (INIS)

    Ibbott, Geoffrey S.; Maryanski, Marek J.; Eastman, Peter; Holcomb, Stephen D.; Yashan, Zhang; Avison, Robin G.; Sanders, Michael; Gore, John C.

    1997-01-01

    Purpose/Objective: The measurement of complex dose distributions (those created by irradiation through multiple beams, multiple sources, or multiple source dwell positions) requires a dosimeter that can integrate the dose during a complete treatment. Integrating dosimeter devices generally are capable of measuring only dose at a point (ion chamber, diode, TLD) or in a plane (film). With increasing use of conformal dose distributions requiring shaped, non coplanar beams, there will be an increased requirement for a dosimeter that can record and display a 3D dose distribution. The use of a 3D dosimeter will be required to confirm the accuracy of treatment plans produced by the current generation of 3D treatment-planning computers. Methods and Materials: The use of a Fricke-infused gel and magnetic resonance imaging (MRI) to demonstrate the localization of stereotactic beams has been demonstrated (11). The recently developed BANG polymer gel dosimetry system (MGS Research, Inc., Guilford, CT), based on radiation-induced chain polymerization of acrylic monomers dispersed in a tissue-equivalent gel, surpasses the Fricke-gel method by providing accurate, quantitative dose distribution data that do not deteriorate with time (6, 9). The improved BANG2 formulation contains 3% N,N'-methylene-bis acrylamide, 3% acrylic acid, 1% sodium hydroxide, 5% gelatin, and 88% water, where all percentages are by weight. The gel was poured into volumetric flasks, of dimensions comparable to a human head. The gels were irradiated with complex beam arrangements, similar to those used for conformal radiation therapy. Images of the gels were acquired using a Siemens 1.5T imager and a Hahn spin-echo pulse sequence (90 deg. -τ-180 deg. -τ-acquire, for different values of τ). The images were transferred via network to a Macintosh computer for which a data analysis and display program was written. The program calculates R2 maps on the basis of multiple TE images, using a monoexponential

  5. New Approach for Segmentation and Quantification of Two-Dimensional Gel Electrophoresis Images

    DEFF Research Database (Denmark)

    Anjo, Antonio dos; Laurell Blom Møller, Anders; Ersbøll, Bjarne Kjær

    2011-01-01

    Motivation: Detection of protein spots in two-dimensional gel electrophoresis images (2-DE) is a very complex task and current approaches addressing this problem still suffer from significant shortcomings. When quantifying a spot, most of the current software applications include a lot of backgro...

  6. Investigation of two different anoxia models by 2-dimensional gel electrophoresis

    DEFF Research Database (Denmark)

    Wulff, Tune; Jessen, Flemming; Hoffmann, Else Kay

    2006-01-01

    anoxia obtained by NaN3 is a widely used model for simulating anoxia (Ossum et al., 2004). The effects of anoxia were studied by protein expression analysis using 2-dimensional gel electrophoresis followed by MS/MS. In this way we were able to separate more than 1500 protein spots with an apparent range...

  7. Use of hydroxyapatite prepared by sol-gel method for gamma ray and electron beam dosimetry

    International Nuclear Information System (INIS)

    Hajiloo, N.; Ziaie, F.; Hesami, M.

    2011-01-01

    In this research, radiation dosimetry was made through measuring free radicals induced in synthetic hydroxyapatite using EPR spectroscopy. At the first step, the hydroxyapatite nano-powders were synthesized via sol-gel method. The produced powders were passed through a thermal treatment, weighted and packed. Then, the samples were irradiated at different dose rates using 60 Co γ-ray and 10 MeV electron beam radiation at a high dose range. The hydroxyapatite signal intensity of hydroxyapatite samples were measured at room temperature in the air. Subsequently, the variations of the EPR signal intensities were constructed as peak-to-peak signal amplitude and were compared with alanine and bone powder samples. The results showed that the EPR signal intensity of the hydroxyapatite samples are several times higher than alanine and bone powder and are saturated at the higher dose rates in comparison with other species.

  8. An assessment of a 3D EPID-based dosimetry system using conventional two- and three-dimensional detectors for VMAT.

    Science.gov (United States)

    Stevens, S; Dvorak, P; Spevacek, V; Pilarova, K; Bray-Parry, M; Gesner, J; Richmond, A

    2018-01-01

    To provide a 3D dosimetric evaluation of a commercial portal dosimetry system using 2D/3D detectors under ideal conditions using VMAT. A 2D ion chamber array, radiochromic film and gel dosimeter were utilised to provide a dosimetric evaluation of transit phantom and pre-treatment 'fluence' EPID back-projected dose distributions for a standard VMAT plan. In-house 2D and 3D gamma methods compared pass statistics relative to each dosimeter and TPS dose distributions. Fluence mode and transit EPID dose distributions back-projected onto phantom geometry produced 2D gamma pass rates in excess of 97% relative to other tested detectors and exported TPS dose planes when a 3%, 3 mm global gamma criterion was applied. Use of a gel dosimeter within a glass vial allowed comparison of measured 3D dose distributions versus EPID 3D dose and TPS calculated distributions. 3D gamma comparisons between modalities at 3%, 3 mm gave pass rates in excess of 92%. Use of fluence mode was indicative of transit results under ideal conditions with slightly reduced dose definition. 3D EPID back projected dose distributions were validated against detectors in both 2D and 3D. Cross validation of transit dose delivered to a patient is limited due to reasons of practicality and the tests presented are recommended as a guideline for 3D EPID dosimetry commissioning; allowing direct comparison between detector, TPS, fluence and transit modes. The results indicate achievable gamma scores for a complex VMAT plan in a homogenous phantom geometry and contributes to growing experience of 3D EPID dosimetry. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Radiation Dosimetry Using Three-Dimensional Optical Random Access Memories

    International Nuclear Information System (INIS)

    Moscovitch, M.

    2001-01-01

    The ability to determine particle type and energy plays an important role in the dosimetry of heavy charged particles (HCP) and neutrons. A new approach to radiation dosimetry is presented, which is shown to be capable of particle type and energy discrimination. This method is based on utilizing radiation induced changes in the digital information stored on three-dimensional optical random access memories (3D ORAM). 3D ORAM is a small cube (a few mm 3 ) composed of poly(methyl methacrylate) doped with a photochromic dye, and it was originally proposed as a memory device in high speed parallel computers. A Nd:YAG laser system is used to write and read binary information (bits) on the ORAM, which functions as a charged particle detector. Both the read and the write processes use two laser beams that simultaneously strike the material to cause a color change at their intersection (similar to the darkening of light-sensitive sunglasses when exposed to sunlight.) The laser produces color changes in the ORAM, which then reverts to the original color (''bit-flips'') at sites where energy is deposited from interaction with incident HCP or neutron-recoil protons. The feasibility of this approach was demonstrated both theoretically and experimentally. Calculations based on track structure theory (TST) predict that when HCP interact with the ORAM material, the local energy deposition is capable of inducing measurable ''bit-flips''. These predictions were recently confirmed experimentally using two types of ORAM systems, one based on spirobenzopyran and the other on anthracene, as the photochromic dyes

  10. Radiation dosimetry using three-dimensional optical random access memories

    International Nuclear Information System (INIS)

    Moscovitch, M.; Phillips, G.W.; Cullum, B.M.; Mobley, J.; Bogard, J.S.; Emfietzoglou, D.; Vo-Dinh, T.

    2002-01-01

    The ability to determine particle type and energy plays an important role in the dosimetry of heavy charged particles (HCP) and neutrons. A new approach to radiation dosimetry is presented, which is shown to be capable of particle type and energy discrimination. This method is based on utilising radiation induced changes in the digital information stored on three-dimensional optical random access memories (3D ORAM). 3D ORAM is a small cube (a few mm 3 ) composed of poly(methyl methacrylate) doped with a photochromic dye, and it was originally proposed as a memory device in high speed parallel computers. A Nd:YAG laser system is used to write and read binary information (bits) on the ORAM, which functions as a charged particle detector. Both the read and the write processes use two laser beams that simultaneously strike the material to cause a colour change at their intersection (similar to the darkening of light-sensitive sunglasses when exposed to sunlight). The laser produces colour changes in the ORAM, which then reverts to the original colour ('bit-flips') at sites where energy is deposited from interaction with incident HCP or neutron-recoil protons. The feasibility of this approach was demonstrated both theoretically and experimentally. Calculations based on track structure theory predict that when HCP interact with the ORAM material, the local energy deposition is capable of inducing measurable 'bit-flips'. These predictions were recently confirmed experimentally using two types of ORAM systems, one based on spirobenzopyran and the other on anthracene, as the photochromic dyes. (author)

  11. Progress in two-dimensional polyacrylamide gel electrophoresis and application in radiation research

    International Nuclear Information System (INIS)

    Wang Zhidong; Chen Xiaohua

    2003-01-01

    Two-dimensional polyacrylamide gel electrophoresis is the key separation technique in proteomics research, which is designed by protein character: molecular weight and PI. Some progress has been made in disease mechanism detection, tumor indicator research and drug development. This technique also has some potential application in radiation research

  12. Acoustic evaluation of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Mather, M.L.; De Deene, Y.; Baldock, C.; Whittaker, A.K.

    2002-01-01

    Advances in radiotherapy treatment techniques such as intensity modulated radiotherapy are placing increasing demands on radiation dosimetry for verification of dose distributions in 3D. In response, polymer gel dosimeters that are capable of recording dose distributions in 3D are currently being developed. Recently, a new technique for evaluation of absorbed dose distributions in these dosimeters using ultrasound was introduced. The current work aims to demonstrate the potential of ultrasound as an evaluation technique for polymer gel dosimeters and to investigate the ultrasound properties of two different dosimeter formulations, PAG and MAGIC gels

  13. Mapping and identification of interferon gamma-regulated HeLa cell proteins separated by immobilized pH gradient two-dimensional gel electrophoresis

    DEFF Research Database (Denmark)

    Shaw, A.; Larsen, M.; Roepstorff, P.

    1999-01-01

    magnitude of IFN-gamma responsive genes has been reported previously. Our goal is to identify and map IFN-gamma-regulated HeLa cell proteins to the two-dimensional polyacrylamide gel electrophoresis with the immobilized pH gradient (IPG) two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) system...

  14. Poster – 13: Evaluation of an in-house CCD camera film dosimetry imaging system for small field deliveries

    Energy Technology Data Exchange (ETDEWEB)

    Lalonde, Michel; Alexander, Kevin; Olding, Tim; Schreiner, L. John; Kerr, Andrew T. [Cancer Centre of Southeastern Ontario at KGH, Queen’s University (Canada)

    2016-08-15

    Purpose: Radiochromic film dosimetry is a standard technique used in clinics to verify modern conformal radiation therapy delivery, and sometimes in research to validate other dosimeters. We are using film as a standard for comparison as we improve high-resolution three-dimensional gel systems for small field dosimetry; however, precise film dosimetry can be technically challenging. We report here measurements for fractionated stereotactic radiation therapy (FSRT) delivered using volumetric modulated arc therapy (VMAT) to investigate the accuracy and reproducibility of film measurements with a novel in-house readout system. We show that radiochromic film can accurately and reproducibly validate FSRT deliveries and also benchmark our gel dosimetry work. Methods: VMAT FSRT plans for metastases alone (PTV{sub MET}) and whole brain plus metastases (WB+PTV{sub MET}) were delivered onto a multi-configurational phantom with a sheet of EBT3 Gafchromic film inserted mid-plane. A dose of 400 cGy was prescribed to 4 small PTV{sub MET} structures in the phantom, while a WB structure was prescribed a dose of 200 cGy in the WB+PTV{sub MET} iterations. Doses generated from film readout with our in-house system were compared to treatment planned doses. Each delivery was repeated multiple times to assess reproducibility. Results and Conclusions: The reproducibility of film optical density readout was excellent throughout all experiments. Doses measured from the film agreed well with plans for the WB+PTV{sub MET} delivery. But, film doses for PTV{sub MET} only deliveries were significantly below planned doses. This discrepancy is due to stray/scattered light perturbations in our system during readout. Corrections schemes will be presented.

  15. Poster – 13: Evaluation of an in-house CCD camera film dosimetry imaging system for small field deliveries

    International Nuclear Information System (INIS)

    Lalonde, Michel; Alexander, Kevin; Olding, Tim; Schreiner, L. John; Kerr, Andrew T.

    2016-01-01

    Purpose: Radiochromic film dosimetry is a standard technique used in clinics to verify modern conformal radiation therapy delivery, and sometimes in research to validate other dosimeters. We are using film as a standard for comparison as we improve high-resolution three-dimensional gel systems for small field dosimetry; however, precise film dosimetry can be technically challenging. We report here measurements for fractionated stereotactic radiation therapy (FSRT) delivered using volumetric modulated arc therapy (VMAT) to investigate the accuracy and reproducibility of film measurements with a novel in-house readout system. We show that radiochromic film can accurately and reproducibly validate FSRT deliveries and also benchmark our gel dosimetry work. Methods: VMAT FSRT plans for metastases alone (PTV MET ) and whole brain plus metastases (WB+PTV MET ) were delivered onto a multi-configurational phantom with a sheet of EBT3 Gafchromic film inserted mid-plane. A dose of 400 cGy was prescribed to 4 small PTV MET structures in the phantom, while a WB structure was prescribed a dose of 200 cGy in the WB+PTV MET iterations. Doses generated from film readout with our in-house system were compared to treatment planned doses. Each delivery was repeated multiple times to assess reproducibility. Results and Conclusions: The reproducibility of film optical density readout was excellent throughout all experiments. Doses measured from the film agreed well with plans for the WB+PTV MET delivery. But, film doses for PTV MET only deliveries were significantly below planned doses. This discrepancy is due to stray/scattered light perturbations in our system during readout. Corrections schemes will be presented.

  16. PREFACE: 7th International Conference on 3D Radiation Dosimetry (IC3DDose)

    Science.gov (United States)

    Thwaites, David; Baldock, Clive

    2013-06-01

    IC3DDose 2013, the 7th International Conference on 3D Radiation Dosimetry held in Sydney, Australia from 4-8 November 2012, grew out of the DosGel series, which began as DosGel99, the 1st International Workshop on Radiation Therapy Gel Dosimetry in Lexington, Kentucky. Since 1999 subsequent DoSGel conferences were held in Brisbane, Australia (2001), Ghent, Belgium (2004), Sherbrooke, Canada (2006) and Crete, Greece (2008). In 2010 the conference was held on Hilton Head Island, South Carolina and underwent a name-change to IC3DDose. The aim of the first workshop was to bring together individuals, both researchers and users, with an interest in 3D radiation dosimetry techniques, with a mix of presentations from basic science to clinical applications, which has remained an objective for all of the meetings. One rationale of DosGel99 was stated as supporting the increasing clinical implementation of gel dosimetry, as the technique appeared, at that time, to be leaving the laboratories of gel dosimetry enthusiasts and entering clinical practice. Clearly by labelling the first workshop as the 1st, there was a vision of a continuing series, which has been fulfilled. On the other hand, the expectation of widespread clinical use of gel dosimetry has perhaps not been what was hoped for and anticipated. Nevertheless the rapidly increasing demand for advanced high-precision 3D radiotherapy technology and techniques has continued apace. The need for practical and accurate 3D dosimetry methods for development and quality assurance has only increased. By the 6th meeting, held in South Carolina in 2010, the Conference Scientific Committee recognised the wider developments in 3D systems and methods and decided to widen the scope, whilst keeping the same span from basic science to applications. This was signalled by a change of name from 'Dosgel' to 'IC3DDose', a name that has continued to this latest conference. The conference objectives were: to enhance the quality and accuracy of

  17. Three dimensional measurements of absorbed dose in BNCT by Fricke-gel imaging

    International Nuclear Information System (INIS)

    Gambarini, G.; Agosteo, S.; Marchesi, P.; Nava, E.; Palazzi, P.; Pecci, A.; Rosa, R.; Rosi, G.; Tinti, R.

    2001-01-01

    A method has been studied for absorbed dose imaging and profiling in a phantom exposed to thermal or epithermal neutron fields, also discriminating between various contributions to the absorbed dose. The proposed technique is based on optical imaging of FriXy-gel phantoms, which are proper tissue-equivalent phantoms acting as continuous dosimeters. Convenient modifications in phantom composition allow, from differential measurements, the discrimination of various contributions to the absorbed dose. The dosimetry technique is based on a chemical dosimeter incorporated in a tissue-equivalent gel (Agarose). The chemical dosimeter is a ferrous sulphate solution (which is the main component of the standard Fricke dosimeter) added with a metal ion indicator (Xylenol Orange). The absorbed dose is measured by analysing the variation of gel optical absorption in the visible spectrum, imaged by means of a CCD camera provided with a suitable filter. The technique validity has been tested by irradiating and analysing phantoms in the thermal facility of the fast research reactor TAPIRO (ENEA, Casaccia, Italy). In a cylindrical phantom simulating a head, we have imaged the therapy dose from thermal neutron reactions with 10 B and the dose in healthy tissue not containing boron. In tissue without boron, we have discriminated between the two main contributions to the absorbed dose, which comes from the 1 H(n,γ) 2 H and 14 N(n,p) 14 C reactions. The comparison with the results of other experimental techniques and of simulations reveals that the technique is very promising. A method for the discrimination of fast neutron contribution to the absorbed dose, still in an experimental stage, is proposed too. (author)

  18. Dosimetric advancement of high-dose-rate after-loading 192Ir source

    International Nuclear Information System (INIS)

    Zhang Shuxu; Li Wenhua; Xu Hairong

    2004-01-01

    High-dose-rate (HDR) 192 Ir source is a nuclide commonly used in the brachytherapy system. The basic dosimetry data of the near source area is usually measured by pin ion chambers or TLD techniques, but these methods have a lower spatial resolution than Electron spin resonance (ESR) dosimetry which has a spatial resolution of 156 μm, and the Monte Carlo photon transport simulations are taken as the golden standard of those measures. The precision in two-dimensional dose distribution measured by GafChromic film is reported to be 1.0%. In vivo dosimetry using TLD during HDR intracavitary after-loading brachytherapy is a good predictor of late rectal complications. The accuracy of magnetic resonance imaging (MRI) Fricke-gel dosimetry for three-dimensional dose distribution is about 2.5% with a spatial resolution of 1.56 mm. The optical computed tomography polymer gel dosimetry has a unique advance than MRI gel dosimetry

  19. Two-dimensional gel electrophoresis of selenized yeast and autoradiography of 75Se-containing proteins

    International Nuclear Information System (INIS)

    Chery, C.C.; Dumont, E.; Cornelis, R.; Moens, L.

    2001-01-01

    Two-dimensional high-resolution gel electrophoresis (2DE) has been applied to the fractionation of 75 Se-containing proteins in yeast, grown in 75 Se-containing medium, and autoradiography was used for detection of the 75 Se-containing proteins. Gel filtration and ultrafiltration were used to check whether the selenium side-chains were stable in the presence of the chemicals used for lysis and 2DE. The mass distribution of the selenium-containing proteins was estimated by use of gel filtration and the results were compared with the distribution obtained by 2DE. A 2DE map of selenium-containing proteins in yeast is presented, and compared with a total protein map of yeast. (orig.)

  20. Application of Fluorescence Two-Dimensional Difference In-Gel Electrophoresis as a Proteomic Biomarker Discovery Tool in Muscular Dystrophy Research

    Science.gov (United States)

    Carberry, Steven; Zweyer, Margit; Swandulla, Dieter; Ohlendieck, Kay

    2013-01-01

    In this article, we illustrate the application of difference in-gel electrophoresis for the proteomic analysis of dystrophic skeletal muscle. The mdx diaphragm was used as a tissue model of dystrophinopathy. Two-dimensional gel electrophoresis is a widely employed protein separation method in proteomic investigations. Although two-dimensional gels usually underestimate the cellular presence of very high molecular mass proteins, integral membrane proteins and low copy number proteins, this method is extremely powerful in the comprehensive analysis of contractile proteins, metabolic enzymes, structural proteins and molecular chaperones. This gives rise to two-dimensional gel electrophoretic separation as the method of choice for studying contractile tissues in health and disease. For comparative studies, fluorescence difference in-gel electrophoresis has been shown to provide an excellent biomarker discovery tool. Since aged diaphragm fibres from the mdx mouse model of Duchenne muscular dystrophy closely resemble the human pathology, we have carried out a mass spectrometry-based comparison of the naturally aged diaphragm versus the senescent dystrophic diaphragm. The proteomic comparison of wild type versus mdx diaphragm resulted in the identification of 84 altered protein species. Novel molecular insights into dystrophic changes suggest increased cellular stress, impaired calcium buffering, cytostructural alterations and disturbances of mitochondrial metabolism in dystrophin-deficient muscle tissue. PMID:24833232

  1. Sources of variability among replicate samples separated by two-dimensional gel electrophoresis.

    Science.gov (United States)

    Bland, Alison M; Janech, Michael G; Almeida, Jonas S; Arthur, John M

    2010-04-01

    Two-dimensional gel electrophoresis (2DE) offers high-resolution separation for intact proteins. However, variability in the appearance of spots can limit the ability to identify true differences between conditions. Variability can occur at a number of levels. Individual samples can differ because of biological variability. Technical variability can occur during protein extraction, processing, or storage. Another potential source of variability occurs during analysis of the gels and is not a result of any of the causes of variability named above. We performed a study designed to focus only on the variability caused by analysis. We separated three aliquots of rat left ventricle and analyzed differences in protein abundance on the replicate 2D gels. As the samples loaded on each gel were identical, differences in protein abundance are caused by variability in separation or interpretation of the gels. Protein spots were compared across gels by quantile values to determine differences. Fourteen percent of spots had a maximum difference in intensity of 0.4 quantile values or more between replicates. We then looked individually at the spots to determine the cause of differences between the measured intensities. Reasons for differences were: failure to identify a spot (59%), differences in spot boundaries (13%), difference in the peak height (6%), and a combination of these factors (21). This study demonstrates that spot identification and characterization make major contributions to variability seen with 2DE. Methods to highlight why measured protein spot abundance is different could reduce these errors.

  2. A bead-spring chain as a one-dimensional polyelectrolyte gel.

    Science.gov (United States)

    Manning, Gerald S

    2018-05-23

    The physical principles underlying expansion of a single-chain polyelectrolyte coil caused by Coulomb repulsions among its ionized groups, and the expansion of a cross-linked polyelectrolyte gel, are probably the same. In this paper, we analyze a "one-dimensional" version of a gel, namely, a linear chain of charged beads connected by Hooke's law springs. In the Debye-Hückel range of relatively weak Coulomb strength, where counterion condensation does not occur, the springs are realistically stretched on a nanolength scale by the repulsive interactions among the beads, if we use a spring constant normalized by the inverse square of the solvent Bjerrum length. The persistence length and radius of gyration counter-intuitively decrease when Coulomb strength is increased, if analyzed in the framework of an OSF-type theory; however, a buckling theory generates the increase that is consistent with bead-spring simulations.

  3. Two dimensional Raman mapping with respect to carbon bonds of radiochromic films: An approach to micro-dosimetry

    International Nuclear Information System (INIS)

    Heo, Taemin; Park, Hyeonsuk; Ye, Sung-Joon

    2015-01-01

    Raman spectroscopy usually provides fingerprints of chemical component species and molecular motion. Raman peak intensity can be quantified as dose changes. Using that Raman peak intensity is proportional to the electric field intensity of incidence beam and the concentration of compounds, the dose trend would have the linearity with the concentration change of radio-active compounds. Raman spectroscopy has been applied to be utilized as a dosimetry in our group in the previous study. Then, laser effect and film homogeneity issues were required to be overcome. Two dimensional scan method was adapted to reduce measurement uncertainty since Raman cross-section is very sensitive to atomic bonds concentration and a large number of point measurements would guarantee reliable data group. The concentration in carbon double and triple bonds of radiochromic films would change by polymerization process. Thus, two dimensional analysis based on Raman mapping provides more reliable data in light of polymerization quantity due to radiation ionization than optical scanning. Its high spatial resolution (fifty micrometers) and low dose sensitivity (10 cGy) were demonstrated as a potential dosimeter. Raman analysis is expected as more precise analysis for micro-dosimetry in the future

  4. In vivo dosimetry: measurement of entrance and exit dose using MOSFET dosimeter

    International Nuclear Information System (INIS)

    Gopiraj, A.; Billimagga, Ramesh S.; Rekha, M.; Ramasubramaniam, V.

    2007-01-01

    Patient dose verification is an essential part of a Quality Assurance (QA) program in a Radiotherapy Department. As the transition is made from the conventional two-dimensional (2D) to three-dimensional (3D) conformal and intensity modulated therapy, it is recommended that new treatment techniques be checked systematically to guarantee accurate dose delivery by means of a comprehensive in vivo dosimetry program (i.e. real-time dosimetry during patient treatment). The authors conducted a study to assess the clinical utility of in vivo dosimetry in the Dept. of Radiation Oncology using MOSFET dosimetry system

  5. [Study on the method of two dimensional polycrylamide gel electrophoresis on rat condylar chondrocyte].

    Science.gov (United States)

    Wu, Tuo-jiang; Li, Huang; Ma, Qiao-lin; Wang, Wen-mei

    2010-08-01

    To investigate the protein profile by two dimensional polycrylamide gel electrophoresis on the rat condylar chondrocyte in vitro. The third-passage chondrocytes were harvested from the mandibular condyles of 2-day-old rats in this study. The protein profile of the rat mandibular condylar chondrocytes was examined by two dimensional polycrylamide gel electrophoresis (2-DE-PAGE). The 2-DE gel maps on different pH gradients were obtained. The result of modified coomassi blue-sliver staining and sliver staining was compared using Pdquest 7.1 image analysis software. The results showed that the good protein profile of the condylar chondrocytes was obtained by standard Bio-Rad manual. The protein was mainly in the field from pH4 to pH7. The 1203±86 protein points were examined on 2-DE gel map by modified coomassi blue-sliver staining, and 1769±97 protein points was examined by sliver staining. The silver staining map showed more distinctly but higher background than modified coomassi blue-sliver staining. The protein profile of the condylar chondrocytes enriches the proteomic database and gives evidence to further proteomic research. The 2-DE map obtained by modified coomassi blue-sliver staining is more suitable for MALDI-TOF mass identification. Supported by National Natural Science Foundation of China (Grant No. C30700963), China Postdoctoral Science Foundation(Grant No.20090461088), Jiangsu Provincial Postdoctoral Science Foundation (Grant No.0802003C) and Nanjing City's Science and Technology Foundation (Grant No.200905011).

  6. 3D dosimetry in HDR brachytherapy resonance imaging nuclear magnetic (b= 0.2 t) using a base acrylic gel (MAGIC)

    International Nuclear Information System (INIS)

    Batista Hernandez, Guillermo; Velez, Graciela R.; Schurrer, Clemar

    2009-01-01

    Dosimetry gels using magnetic resonance imaging (MRI) has been extended in recent literature. Our study presents the preparation, calibration IRM of acrylic gel (MAGIC) and its application in measuring dose in a 3D distribution HDR Brachytherapy with 192Ir source. The first gels used were the type Fricke gels based on the relationship of dose and time T1 relaxation. In 2001, Fong presented a new normoxic gel known as MAGIC whose main components are Methacrylic Acid (polymerizing), and Hydroquinone (inhibitor of self-curing) based on the relationship of dose and T2 relaxation time. Subsequent studies make changes in the concentrations component of the MAGIC (Methacrylic Acid and Hydroquinone in particular) to observe the behavior of the sensitivity of the gel with respect to its components and beam magnetic resonance equipment using magnetic fields higher to 0.5 T. This is done with equipment available to the staff of a Radiotherapy clinic setting. MAGIC gel is prepared according to composition by Crescenti (6% methacrylic acid), is calibrated with a 60Co unit TERADI INVAP 8002c (Argentina). Was raised shooting in a Siemens MRI scanner of 0.2 T Magnetom Concerto irradiated with a team of Brachytherapy High Dose Rate (HDR) Micro selectron Nucletron's V2 HDR for comparison with dose distributions provided by the planning system from Nucletron PLATO Sunrise. Was obtained a calibration curve for doses ranging from 0 to 8.0 Gy and a field strength 0.2 T magnetic We compared the sensitivity obtained in our calibration (Slope of the calibration curve) with those presented in the literature. Two phantoms were prepared for measurement in brachytherapy: a PMMA and a PVC. It was noted that MAGIC gel reacts chemically with PMMA and cured prior to irradiation. The phantom of PVC (no reactions) were irradiated with Micro selectron equipment and measured the dose distribution in 3D MRI. Were measured doses at the points specified by the Planning System and PLATO Sunrise compared

  7. Evaluation of the Accuracy of Polymer Gels for Determining Electron Dose Distributions in the Presence of Small Heterogeneities.

    Science.gov (United States)

    Asl, R Ghahraman; Nedaie, H A; Banaee, N

    2017-12-01

    The aim of this study is to evaluate the application and accuracy of polymer gels for determining electron dose distributions in the presence of small heterogeneities made of bone and air. Different cylindrical phantoms containing MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) normoxic polymer gel were used under the slab phantoms during irradiation. MR images of the irradiated gel phantoms were obtained to determine their R2 (spin-spin) relaxation maps for conversion to absorbed dose. One- and 2-dimensional lateral dose profiles were acquired at depths of 1 and 4 cm for 8 and 15 MeV electron beams. The results were compared with the doses measured by a diode detector at the same positions. In addition, the dose distribution in the axial orientation was measured by the gel dosimeter. The slope and intercept for the R2 versus dose curve were 0.509 ± 0.002 Gy s and 4.581 ± 0.005 s, respectively. No significant variation in dose-R2 response was seen for the two electron energies within the applied dose ranges. The mean dose difference between the measured gel dose profiles was smaller than 3% compared to those measured by the diode detector. These results provide further demonstration that electron dose distributions are significantly altered in the presence of tissue inhomogeneities such as bone and air cavity and that MAGIC gel is a useful tool for 3-dimensional dose visualization and qualitative assessment of tissue inhomogeneity effects in electron beam dosimetry.

  8. SU-E-T-243: MonteCarlo Simulation Study of Polymer and Radiochromic Gel for Three-Dimensional Proton Dose Distribution

    International Nuclear Information System (INIS)

    Park, M; Jung, H; Kim, G; Ji, Y; Kim, K; Park, S

    2014-01-01

    Purpose: To estimate the three dimensional dose distributions in a polymer gel and a radiochromic gel by comparing with the virtual water phantom exposed to proton beams by applying Monte Carlo simulation. Methods: The polymer gel dosimeter is the compositeness material of gelatin, methacrylic acid, hydroquinone, tetrakis, and distilled water. The radiochromic gel is PRESAGE product. The densities of polymer and radiochromic gel were 1.040 and 1.0005 g/cm3, respectively. The shape of water phantom was a hexahedron with the size of 13 × 13 × 15 cm3. The proton beam energies of 72 and 116 MeV were used in the simulation. Proton beam was directed to the top of the phantom with Z-axis and the shape of beam was quadrangle with 10 × 10 cm2 dimension. The Percent depth dose and the dose distribution were evaluated for estimating the dose distribution of proton particle in two gel dosimeters, and compared with the virtual water phantom. Results: The Bragg-peak for proton particles in two gel dosimeters was similar to the virtual water phantom. Bragg-peak regions of polymer gel, radiochromic gel, and virtual water phantom were represented in the identical region (4.3 cm) for 72 MeV proton beam. For 116 MeV proton beam, the Bragg-peak regions of polymer gel, radiochromic gel, and virtual water phantom were represented in 9.9, 9.9 and 9.7 cm, respectively. The dose distribution of proton particles in polymer gel, radiochromic gel, and virtual water phantom was approximately identical in the case of 72 and 116 MeV energies. The errors for the simulation were under 10%. Conclusion: This work indicates the evaluation of three dimensional dose distributions by exposing proton particles to polymer and radiochromic gel dosimeter by comparing with the water phantom. The polymer gel and the radiochromic gel dosimeter show similar dose distributions for the proton beams

  9. Evolution of virtual simulation and three-dimensional dosimetry practices in mammary pathology in 18 radiotherapy departments of the Grand-East region; Evolution des pratiques de simulation virtuelle et de dosimetrie tridimensionnelle en pathologie mammaire de 18 services de radiotherapie du Grand-Est

    Energy Technology Data Exchange (ETDEWEB)

    Marchal, C.; Marchesi, V.; Peiffert, D. [Centre Alexis-Vautrin, 54 - Nancy (France); Nguyen Tan, D. [Centre Jean-Godinot, 51 - Reims (France)

    2010-10-15

    Based on questionnaires and regional meetings, the authors report the assessment of the evolution of professional practices as far passing from conventional simulation to virtual simulation, and from two-dimensional to three-dimensional dosimetry is concerned, particularly in the field of mammary pathology. Short communication

  10. Electrophoretic analysis of proteins from Mycoplasma hominis strains detected by SDS-PAGE, two-dimensional gel electrophoresis and immunoblotting

    DEFF Research Database (Denmark)

    Andersen, H; Birkelund, Svend; Christiansen, Gunna

    1987-01-01

    The proteins of 14 strains of Mycoplasma hominis were compared by SDS-PAGE in gradient gels, by two-dimensional (2D) gel electrophoresis of extracts of 35S-labelled cells and by immunoblot analysis of cell proteins. The strains examined included the M. hominis type strain PG21 and 13 others...... isolated variously from genital tract, mouth, blood, upper urinary tract and a wound. These 14 strains shared 76-99% of proteins in SDS-gradient gel analysis and 41-72% in the 2D gels. As expected, the immunoblot analysis likewise revealed the existence of an extensive common protein pattern in M. hominis...

  11. Initial investigation of a novel light-scattering gel phantom for evaluation of optical CT scanners for radiotherapy gel dosimetry

    International Nuclear Information System (INIS)

    Bosi, Stephen; Naseri, Pourandokht; Puran, Alicia; Davies, Justin; Baldock, Clive

    2007-01-01

    There is a need for stable gel materials for phantoms used to validate optical computerized tomography (CT) scanners used in conjunction with radiation-induced polymerizing gel dosimeters. Phantoms based on addition of light-absorbing dyes to gelatine to simulate gel dosimeters have been employed. However, to more accurately simulate polymerizing gels one requires phantoms that employ light-scattering colloidal suspensions added to the gel. In this paper, we present the initial results of using an optical CT scanner to evaluate a novel phantom in which radiation-exposed polymer gels are simulated by the addition of colloidal suspensions of varying turbidity. The phantom may be useful as a calibration transfer standard for polymer gel dosimeters. The tests reveal some phenomena peculiar to light-scattering gels that need to be taken into account when calibrating polymer gel dosimeters

  12. Dosimetric evaluation of the Fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

    International Nuclear Information System (INIS)

    Mangueira, Thyago Fressatti

    2009-01-01

    In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams. (author)

  13. Fixed, object-specific intensity compensation for cone beam optical CT radiation dosimetry

    Science.gov (United States)

    Dekker, Kurtis H.; Hazarika, Rubin; Silveira, Matheus A.; Jordan, Kevin J.

    2018-03-01

    Optical cone beam computed tomography (CT) scanning of radiochromic gel dosimeters, using a CCD camera and a low stray light convergent source, provides fast, truly 3D radiation dosimetry with high accuracy. However, a key limiting factor in radiochromic gel dosimetry at large (⩾10 cm diameter) volumes is the initial attenuation of the dosimeters. It is not unusual to observe a 5–10×  difference in signal intensity through the dosimeter center versus through the surrounding medium in pre-irradiation images. Thus, all dosimetric information in a typical experiment is measured within the lower 10%–20% of the camera sensor’s range, and re-use of gels is often not possible due to a lack of transmission. To counteract this, in this note we describe a simple method to create source compensators by printing on transparent films. This technique, which is easily implemented and inexpensive, is an optical analogue to the bowtie filter in x-ray CT. We present transmission images and solution phantom reconstructions to demonstrate that (1) placing compensators beyond the focal zone of the imaging lens prevents high spatial frequency features of the printed films from generating reconstruction artifacts, and (2) object-specific compensation considerably reduces the range of intensities measured in projection images. This will improve the measurable dose range in optical CT dosimetry, and will enable imaging of larger gel volumes (∼15 cm diameter). Additionally, it should enable re-use of dosimeters by printing a new compensator for a second experiment.

  14. Preliminary study on biological dosimetry using alkaline single cell gel electrophoresis of human peripheral lymphocytes

    International Nuclear Information System (INIS)

    Liu Qingjie; Lu Xue; Feng Jiangbing; Chen Deqing; Chen Xiaosui

    2006-01-01

    Objective: To explore the feasibility of alkaline single cell gel electrophoresis (SCGE) in biological dosimetry of ionizing radiation. Methods: Normal peripheral blood samples from two healthy males were exposed to different doses coblat-60 gamma-rays, ranged from 0 to 5 Gy, and the tail length (TL) and Oliver tail moment (TM) of the lymphocytes were analyzed with SCGE. The dose-effect curves of TL and TM were fitted respectively. The TL and TM of lymphocytes for eight radiation workers were analyzed with SCGE, cumulative doses were estimated using the fitted TL and TM equations, and then compared with the recorded monitoring doses. Results: The TLs or TMs of normal human lymphocytes were increased with the irradiation doses, and its relationship can be fitted with a linear-quadratic equations: Y=13.59 + 20.87X - 2.27 X 2 for TL, and Y = 8.50 + 15.04X - 1.43X 2 for TM, respectively (Y denotes TL or TM value, X is radiation dose). The doses estimated with TM equation were closer to the recorded monitoring doses than that with TL equation. Conclusions: The TM in lymphocytes analyzed with SCGE is a promising radiation biological dosimeter. (authors)

  15. Implementation of nuclear magnetic resonance polymer-gel dosimetry into clinical practice

    International Nuclear Information System (INIS)

    Novotny, Josef Jr.

    2003-01-01

    The aim of this thesis research was to evaluate some basic properties of the polymer-gel dosimeter and test it in clinical practice. Dependence of polymer-gel dosimeter sensitivity on different photon and electron energies as well as on different mean dose rates of standard clinically used linear accelerator was studied. A physical/mathematical description of the effect of temperature on the polymer-gel dosimeter, able to correct a dosimeter 1/T2 response for different temperatures during the NMR measurement, was developed. The polymer-gel dosimeter was tested for the verification of stereotactic radiosurgery techniques with the Leksell Gamma Knife. There was an observed trend in polymer-gel dosimeter sensitivity dependence on quality index for the high-energy x ray beams. Similarly, there was an observed trend in dosimeter sensitivity dependence on mean electron energy. It was demonstrated that these trends were statistically significant. Polymer-gel dosimeter sensitivity was decreased with increased photon or electron energy. There was observed no trend in polymer-gel dosimeter sensitivity dependence on mean dose rates for both photon and electron beams within experimental errors. It was demonstrated in this study that the NMR 1/T2-dose response is increased for lower temperatures of the evaluated polymer-gel samples. The relaxation rate response can be expressed as a function consisting of two terms, one denoted for the temperature dependence and the other one for the dose dependence. Two clinical applications of the polymer-gel dosimeter were demonstrated in this study. The first experiment allowed a check of the entire stereotactic procedure with the Leksell gamma knife including target stereotactic localization on NMR, treatment planning, and irradiation. The second experiment evaluated dosimetric and geometric inaccuracies associated with the stereotactic irradiation of the experimental rat brain. It was demonstrated that polymer-gel can be effectively used

  16. Proteome analysis of barley seeds: Identification of major proteins from two-dimensional gels (pl 4-7)

    DEFF Research Database (Denmark)

    Østergaard, O.; Finnie, Christine; Laugesen, S.

    2004-01-01

    inhibitors), and proteins related to desiccation and oxidative stress. Sixty-four of the identifications were made using expressed sequence tags (ESTs). Numerous spots in the 2-D gel pattern changed during germination (micromalting) and an intensely stained area which contained large amounts of the serpin......Germination of monocotyledonous plants involves activation and de novo synthesis of enzymes that degrade cell walls and starch and mobilize stored endosperm reserves for embryo growth. Two-dimensional (2-D) gel electrophoresis and mass spectrometry were applied to identify major water...

  17. Effect of Gold Nanoparticles on Prostate Dose Distribution under Ir-192 Internal and 18 MV External Radiotherapy Procedures Using Gel Dosimetry and Monte Carlo Method

    Directory of Open Access Journals (Sweden)

    Khosravi H.

    2015-03-01

    Full Text Available Background: Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions. Objective: The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC method for studying the effect of gold nanoparticles (GNPs in prostate dose distributions under the internal Ir-192 and external 18MV radiotherapy practices. Method: A Plexiglas phantom was made representing human pelvis. The GNP shaving 15 nm in diameter and 0.1 mM concentration were synthesized using chemical reduction method. Then, a new formulation of MAGIC-f gel was synthesized. The fabricated gel was poured in the tubes located at the prostate (with and without the GNPs and bladder locations of the phantom. The phantom was irradiated to an Ir-192 source and 18 MV beam of a Varian linac separately based on common radiotherapy procedures used for prostate cancer. After 24 hours, the irradiated gels were read using a Siemens 1.5 Tesla MRI scanner. The absolute doses at the reference points and isodose curves resulted from the experimental measurement of the gels and MC simulations following the internal and external radiotherapy practices were compared. Results: The mean absorbed doses measured with the gel in the presence of the GNPs in prostate were 15% and 8 % higher than the corresponding values without the GNPs under the internal and external radiation therapies, respectively. MC simulations also indicated a dose increase of 14 % and 7 % due to presence of the GNPs, for the same experimental internal and external radiotherapy practices, respectively. Conclusion: There was a good agreement between the dose enhancement factors (DEFs estimated with MC simulations and experiment gel measurements due to the GNPs. The results indicated that the polymer gel dosimetry method as developed and used in this study, can be recommended as a reliable method for investigating the DEF of GNPs in internal

  18. Effect of Gold Nanoparticles on Prostate Dose Distribution under Ir-192 Internal and 18 MV External Radiotherapy Procedures Using Gel Dosimetry and Monte Carlo Method.

    Science.gov (United States)

    Khosravi, H; Hashemi, B; Mahdavi, S R; Hejazi, P

    2015-03-01

    Gel polymers are considered as new dosimeters for determining radiotherapy dose distribution in three dimensions. The ability of a new formulation of MAGIC-f polymer gel was assessed by experimental measurement and Monte Carlo (MC) method for studying the effect of gold nanoparticles (GNPs) in prostate dose distributions under the internal Ir-192 and external 18MV radiotherapy practices. A Plexiglas phantom was made representing human pelvis. The GNP shaving 15 nm in diameter and 0.1 mM concentration were synthesized using chemical reduction method. Then, a new formulation of MAGIC-f gel was synthesized. The fabricated gel was poured in the tubes located at the prostate (with and without the GNPs) and bladder locations of the phantom. The phantom was irradiated to an Ir-192 source and 18 MV beam of a Varian linac separately based on common radiotherapy procedures used for prostate cancer. After 24 hours, the irradiated gels were read using a Siemens 1.5 Tesla MRI scanner. The absolute doses at the reference points and isodose curves resulted from the experimental measurement of the gels and MC simulations following the internal and external radiotherapy practices were compared. The mean absorbed doses measured with the gel in the presence of the GNPs in prostate were 15% and 8 % higher than the corresponding values without the GNPs under the internal and external radiation therapies, respectively. MC simulations also indicated a dose increase of 14 % and 7 % due to presence of the GNPs, for the same experimental internal and external radiotherapy practices, respectively. There was a good agreement between the dose enhancement factors (DEFs) estimated with MC simulations and experiment gel measurements due to the GNPs. The results indicated that the polymer gel dosimetry method as developed and used in this study, can be recommended as a reliable method for investigating the DEF of GNPs in internal and external radiotherapy practices.

  19. Three-dimensional determination of absorbed dose by spectrophotometric analysis of ferrous-sulphate agarose gel

    International Nuclear Information System (INIS)

    Gambarini, G.; Gomarasca, G.; Marchesini, R.; Pecci, A.; Pirola, L.; Tomatis, S.

    1999-01-01

    We describe a technique to obtain three-dimensional (3-D) imaging of an absorbed dose by optical transmittance measurements of phantoms composed by agarose gel in which a ferrous sulphate and xylenol orange solution are incorporated. The analysis of gel samples is performed by acquiring transmittance images with a system based on a CCD camera provided with an interference filter matching the optical absorption peak of interest. The proposed technique for 3-D measurements of an absorbed dose is based on the imaging of phantoms composed of sets of properly piled up gel slices. The slice thickness was optimized in order to obtain a good image contrast as well as a good in-depth spatial resolution. To test the technique, a phantom has been irradiated with a collimated γ-beam and then analysed. Proper software was adapted in order to visualise the images of all slices and to attain the 2-D profiles of the dose absorbed by each slice

  20. Optimizing human synovial fluid preparation for two-dimensional gel electrophoresis.

    Science.gov (United States)

    Chen, Carl Pc; Hsu, Chih-Chin; Yeh, Wen-Lin; Lin, Hsiu-Chu; Hsieh, Sen-Yung; Lin, Shih-Cherng; Chen, Tai-Tzung; Chen, Max Jl; Tang, Simon Ft

    2011-10-11

    Proteome analysis is frequently applied in identifying the proteins or biomarkers in knee synovial fluids (SF) that are associated with osteoarthritis and other arthritic disorders. The 2-dimensional gel electrophoresis (2-DE) is the technique of choice in these studies. Disease biomarkers usually appear in low concentrations and may be masked by high abundant proteins. Therefore, the main aim of this study was to find the most suitable sample preparation method that can optimize the expression of proteins on 2-DE gels that can be used to develop a reference proteome picture for non-osteoarthritic knee synovial fluid samples. Proteome pictures obtained from osteoarthritic knee synovial fluids can then be compared with the reference proteome pictures obtained in this study to assist us in identifying the disease biomarkers more correctly. The proteomic tool of 2-DE with immobilized pH gradients was applied in this study. A total of 12 2-DE gel images were constructed from SF samples that were free of osteoarthritis. In these samples, 3 were not treated with any sample preparation methods, 3 were treated with acetone, 3 were treated with 2-DE Clean-Up Kit, and 3 were treated with the combination of acetone and 2-D Clean-Up Kit prior to 2-DE analysis. Gel images were analyzed using the PDQuest Basic 8.0.1 Analytical software. Protein spots that were of interest were excised from the gels and sent for identification by mass spectrometry. Total SF total protein concentration was calculated to be 21.98 ± 0.86 mg/mL. The untreated SF samples were detected to have 456 ± 33 protein spots on 2-DE gel images. Acetone treated SF samples were detected to have 320 ± 28 protein spots, 2-D Clean-Up Kit treated SF samples were detected to have 413 ± 31 protein spots, and the combined treatment method of acetone and 2-D Clean-Up Kit was detected to have 278 ± 26 protein spots 2-DE gel images. SF samples treated with 2-D Clean-Up Kit revealed clearer presentation of the isoforms

  1. Optimizing Human Synovial Fluid Preparation for Two-Dimensional Gel Electrophoresis

    Directory of Open Access Journals (Sweden)

    Chen Max JL

    2011-10-01

    Full Text Available Abstract Background Proteome analysis is frequently applied in identifying the proteins or biomarkers in knee synovial fluids (SF that are associated with osteoarthritis and other arthritic disorders. The 2-dimensional gel electrophoresis (2-DE is the technique of choice in these studies. Disease biomarkers usually appear in low concentrations and may be masked by high abundant proteins. Therefore, the main aim of this study was to find the most suitable sample preparation method that can optimize the expression of proteins on 2-DE gels that can be used to develop a reference proteome picture for non-osteoarthritic knee synovial fluid samples. Proteome pictures obtained from osteoarthritic knee synovial fluids can then be compared with the reference proteome pictures obtained in this study to assist us in identifying the disease biomarkers more correctly. Results The proteomic tool of 2-DE with immobilized pH gradients was applied in this study. A total of 12 2-DE gel images were constructed from SF samples that were free of osteoarthritis. In these samples, 3 were not treated with any sample preparation methods, 3 were treated with acetone, 3 were treated with 2-DE Clean-Up Kit, and 3 were treated with the combination of acetone and 2-D Clean-Up Kit prior to 2-DE analysis. Gel images were analyzed using the PDQuest Basic 8.0.1 Analytical software. Protein spots that were of interest were excised from the gels and sent for identification by mass spectrometry. Total SF total protein concentration was calculated to be 21.98 ± 0.86 mg/mL. The untreated SF samples were detected to have 456 ± 33 protein spots on 2-DE gel images. Acetone treated SF samples were detected to have 320 ± 28 protein spots, 2-D Clean-Up Kit treated SF samples were detected to have 413 ± 31 protein spots, and the combined treatment method of acetone and 2-D Clean-Up Kit was detected to have 278 ± 26 protein spots 2-DE gel images. SF samples treated with 2-D Clean-Up Kit

  2. Fundamentals of Polymer Gel Dosimeters

    Science.gov (United States)

    McAuley, Kim B.

    2006-12-01

    The recent literature on polymer gel dosimetry contains application papers and basic experimental studies involving polymethacrylic-acid-based and polyacrylamide-based gel dosimeters. The basic studies assess the relative merits of these two most commonly used dosimeters, and explore the effects of tetrakis hydroxymethyl phosphonium chloride (THPC) antioxidant on dosimeter performance. Polymer gel dosimeters that contain THPC or other oxygen scavengers are called normoxic dosimeters, because they can be prepared under normal atmospheric conditions, rather than in a glove box that excludes oxygen. In this review, an effort is made to explain some of the underlying chemical phenomena that affect dosimeter performance using THPC, and that lead to differences in behaviour between dosimeters made using the two types of monomer systems. Progress on the development of new more effective and less toxic dosimeters is also reported.

  3. 3-D dosimetric evaluation of 2.5 mm HD120 multileaf system for intensity modulated stereotactic radiosurgery using optical CT based polymer gel dosimetry

    International Nuclear Information System (INIS)

    Wuu, C-S; Kessel, Jack; Xu, Y

    2009-01-01

    A Trilogy TX equipped with a 2.5 mm HD120 multileaf collimator system is available for the treatment of radiosurgery and IMRT. In this study, we evaluated the 3-D dosimetric impact of leaf width on an IMRT radiosurgery plan by comparing the target coverage and the dose gradient around the target, produced from both a 2.5 mm HD120 high-definition MLC system and a 5mm-leaf-width millennium 120 MLC system, using an optical CT based polymer gel dosimetry system. The 2.5 mm MLC improves target conformity and surrounding tissue sparing when compared to that of 5 mm MLC.

  4. Identification of Cysteine Proteases and Screening of Cysteine Protease Inhibitors in Biological Samples by a Two-Dimensional Gel System of Zymography and Reverse Zymography

    OpenAIRE

    Saitoh, Eiichi; Yamamoto, Shinya; Okamoto, Eishiro; Hayakawa, Yoshimi; Hoshino, Takashi; Sato, Ritsuko; Isemura, Satoko; Ohtsubo, Sadami; Taniguchi, Masayuki

    2007-01-01

    We have developed a two-dimensional (2D-) gel system of zymography and reverse zymography for the detection and characterization of proteases and protease inhibitors. Isoelectric focusing (IEF) agarose gels with pH gradients were employed for separation in the fi rst-dimension and sodium dodecyl sulfate (SDS)-polyacrylamide gel copolymerized with gelatin used for the second dimension. Proteases and protease inhibitors separated by IEF gel were applied on the second gel without trichloroacetic...

  5. Study the Effect of Gamma Radiation on some Solid and Polymeric Materials and Its Possible Applications in Radiation Dosimetry

    International Nuclear Information System (INIS)

    El-Shawadfy, E.R.

    2015-01-01

    Dyed solid materials (films and gels) and dyed solutions dosimeters have wide-spread applications in radiation processing for installation process qualification and routine dose control for both gamma rays and electron beam irradiation. These film dosimeters have been introduced for low- and high-dose monitoring. The introduction of new types of dosimeters is due to the effort of seeking for more reliable, more stable, simpler and cheaper systems as routine dosimeters and/or label dosimeters. The main objective of this work is to study the possibility of preparing dyed solid polymeric materials (dyed films- dyed gels) and dyed solutions, and study the dosimetric studies for the prepared materials. The results obtained in this work can be summarized in the following: Section (1): Deals with the investigation of prepared three dosimetry systems based on Toludine Blue O (TBO) dye, to make them readily usable in high and low-radiation dosimetry applications (e.g. sterilization of medical products, sterilization of pharmaceutical products and polymer modification). This section is divided into three parts: Part I: This part includes the preparation and development of polymeric films for high-dose dosimetry applications, these films are based on poly (vinyl alcohol) dyed with TBO. These flexible plastic film dosimeters are bleached when exposed to gamma-ray photons (i.e. from blue to colorless) at λmax=633 nm. The radiation chemical yield (G-Value) for different concentrations of the dye as well as the dye with additive substances (chloral hydrate) was calculated. It was found that these films are highly stable for long time before and after irradiation under different storage conditions. The response of these films is not affected by humidity change in the range of relative humidity (0-56%). PVA films dyed with TBO are suitable in the dose range from 1-150 kGy. These properties suggest them to be useful for routine and dose mapping in sterilization range of radiation

  6. Dose characterization of the new Bebig IsoSeed'' (registered) I25.S17 using polymer gel and MRI

    Energy Technology Data Exchange (ETDEWEB)

    Pantelis, Evaggelos [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece)]. E-mail: vpantelis@phys.uoa.gr; Baltas, Dimos [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece): Department of Medical Physics and Engineering, Strahlenklinik, Klinikum Offenbach, 63069 Offenbach (Germany); Georgiou, Evaggelos [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece); Karaiskos, Pantelis [Medical Physics Department, University of Athens, 75 Mikras Asias, 115 27 Athens (Greece): Medical Physics Department, Hygeia Hospital, Kiffisias Avenue and 4 Erythrou Stavrou, Marousi, 151 23 Athens (Greece); Lymperopoulou, Georgia [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Papagiannis, Panagiotis [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Sakelliou, Loukas [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece); Seimenis, Ioannis [Philips Hellas Medical Systems, 44 Kifissias Ave., Maroussi 151 25, Athens (Greece); Stilliaris, Efstathios [Nuclear and Particle Physics Section, Physics Department, University of Athens, Panepistimioupolis, Ilisia, 157 71 Athens (Greece): Institute of Accelerating Systems and Applications (IASA), P.O. Box 17214, GR-10024, Athens (Greece)

    2006-12-20

    A new, molybdenum core, {sup 125}I interstitial brachytherapy seed is marketed by Bebig GmbH (IsoSeed'' (registered) I25.S17) and our group has performed its Dosimetric characterization using Monte Carlo (MC) simulation and Thermoluminescence dosimetry (TLD) as recommended by the AAPM TG-43U1 prior to the clinical implementation of new low-energy seeds. This work presents the results of a supplementary experimental dosimetry study performed using PABIG polymer gel and Magnetic Resonance Imaging (MRI). One new I25.S17 seed and a commercially available, gold core, Bebig IsoSeed'' (registered) I25.S06 {sup 125}I seed were positioned at two different locations in a vial filled with water equivalent, PABIG-polymer gel. The gel with the sources in place was MR scanned in 3D at various time intervals after seed placement using a time efficient, 3D, dual echo Turbo Spin Echo pulse sequence. The consensus dosimetry parameters published in the TG-43U1 for the I25.S06 seed were used to derive the gel response calibration curve for each scanning session. The calibration data were then used to provide dosimetry results for the new I25.S17 seed. Experimental results for the new seed in the form of dose distributions as well as dosimetric quantities in the prevalent TG-43 dosimetric formalism were found to be in close agreement with corresponding MC and TLD results. This finding suggests that the polymer gel-MRI method could at least play a supplementary role to TLD dosimetry in the dose characterization of low energy/low dose rate brachytherapy sources, especially in view of its potential for measurements with a fine spatial resolution down to short distances which are inhibitory to conventional experimental techniques.

  7. Evaluation of polymer gels and MRI as a 3-D dosimeter for intensity-modulated radiation therapy.

    Science.gov (United States)

    Low, D A; Dempsey, J F; Venkatesan, R; Mutic, S; Markman, J; Mark Haacke, E; Purdy, J A

    1999-08-01

    BANG gel (MGS Research, Inc., Guilford, CT) has been evaluated for measuring intensity-modulated radiation therapy (IMRT) dose distributions. Treatment plans with target doses of 1500 cGy were generated by the Peacock IMRT system (NOMOS Corp., Sewickley, PA) using test target volumes. The gels were enclosed in 13 cm outer diameter cylindrical glass vessels. Dose calibration was conducted using seven smaller (4 cm diameter) cylindrical glass vessels irradiated to 0-1800 cGy in 300 cGy increments. Three-dimensional maps of the proton relaxation rate R2 were obtained using a 1.5 T magnetic resonance imaging (MRI) system (Siemens Medical Systems, Erlangen, Germany) and correlated with dose. A Hahn spin echo sequence was used with TR = 3 s, TE = 20 and 100 ms, NEX = 1, using 1 x 1 x 3 mm3 voxels. The MRI measurements were repeated weekly to identify the gel-aging characteristics. Ionization chamber, thermoluminescent dosimetry (TLD), and film dosimetry measurements of the IMRT dose distributions were obtained to compare against the gel results. The other dosimeters were used in a phantom with the same external cross-section as the gel phantom. The irradiated R2 values of the large vessels did not precisely track the smaller vessels, so the ionization chamber measurements were used to normalize the gel dose distributions. The point-to-point standard deviation of the gel dose measurements was 7.0 cGy. When compared with the ionization chamber measurements averaged over the chamber volume, 1% agreement was obtained. Comparisons against radiographic film dose distribution measurements and the treatment planning dose distribution calculation were used to determine the spatial localization accuracy of the gel and MRI. Spatial localization was better than 2 mm, and the dose was accurately determined by the gel both within and outside the target. The TLD chips were placed throughout the phantom to determine gel measurement precision in high- and low-dose regions. A

  8. Investigating potential physicochemical errors in polymer gel dosimeters

    International Nuclear Information System (INIS)

    Sedaghat, Mahbod; Lepage, Martin; Bujold, Rachel

    2011-01-01

    Measurement errors in polymer gel dosimetry can originate either during irradiation or scanning. One concern related to the exothermic nature of polymerization reaction was that the heat released in polymer gel dosimeters during irradiation modifies their dose response. In this paper, the effect of heat released from the exothermal polymerization reaction on the dose response of a number of dosimeters was studied. In addition, we investigated whether heat-generated geometric distortion existed in newly proposed gel dosimeters that contain highly thermoresponsive polymers. Our results suggest that despite a significant internal temperature increase in some gel compositions, their dose responses are not affected when oxygen is well expelled mechanically from the gel mixture. We also report on significant pre-irradiation instability in some recently developed polymer gel dosimeters but that geometric distortions were not observed. Data obtained by a set of small calibration vials are compared to those obtained from larger phantoms, and potential physicochemical causes of deviations between them are identified.

  9. Investigating potential physicochemical errors in polymer gel dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Sedaghat, Mahbod; Lepage, Martin [Centre d' imagerie moleculaire de Sherbrooke, Departement de medecine nucleaire et radiobiologie, Universite de Sherbrooke, Sherbrooke, QC (Canada); Bujold, Rachel, E-mail: martin.lepage@usherbrooke.ca [Service de radio-oncologie, Centre hospitalier universitaire de Sherbrooke, Sherbrooke, QC (Canada)

    2011-09-21

    Measurement errors in polymer gel dosimetry can originate either during irradiation or scanning. One concern related to the exothermic nature of polymerization reaction was that the heat released in polymer gel dosimeters during irradiation modifies their dose response. In this paper, the effect of heat released from the exothermal polymerization reaction on the dose response of a number of dosimeters was studied. In addition, we investigated whether heat-generated geometric distortion existed in newly proposed gel dosimeters that contain highly thermoresponsive polymers. Our results suggest that despite a significant internal temperature increase in some gel compositions, their dose responses are not affected when oxygen is well expelled mechanically from the gel mixture. We also report on significant pre-irradiation instability in some recently developed polymer gel dosimeters but that geometric distortions were not observed. Data obtained by a set of small calibration vials are compared to those obtained from larger phantoms, and potential physicochemical causes of deviations between them are identified.

  10. Enhanced detergent extraction for analysis of membrane proteomes by two-dimensional gel electrophoresis

    Directory of Open Access Journals (Sweden)

    Hsu Kimberly K

    2005-06-01

    Full Text Available Abstract Background The analysis of hydrophobic membrane proteins by two-dimensional gel electrophoresis has long been hampered by the concept of inherent difficulty due to solubility issues. We have optimized extraction protocols by varying the detergent composition of the solubilization buffer with a variety of commercially available non-ionic and zwitterionic detergents and detergent-like phospholipids. Results After initial analyses by one-dimensional SDS-PAGE, quantitative two-dimensional analyses of human erythrocyte membranes, mouse liver membranes, and mouse brain membranes, extracted with buffers that included the zwitterionic detergent MEGA 10 (decanoyl-N-methylglucamide and the zwitterionic lipid LPC (1-lauroyl lysophosphatidylcholine, showed selective improvement over extraction with the common 2-DE detergent CHAPS (3 [(3-cholamidopropyldimethylammonio]-1-propanesulfonate. Mixtures of the three detergents showed additive improvements in spot number, density, and resolution. Substantial improvements in the analysis of a brain membrane proteome were observed. Conclusion This study demonstrates that an optimized detergent mix, coupled with rigorous sample handling and electrophoretic protocols, enables simple and effective analysis of membrane proteomes using two-dimensional electrophoresis.

  11. Laser CT evaluation on normoxic PAGAT gel dosimeter

    International Nuclear Information System (INIS)

    Kumar, D S; Samuel, E J J; Watanabe, Y

    2013-01-01

    Optical computed tomography has been shown to be a potentially useful imaging tool for the radiation therapy physicists. In radiation therapy, researchers have used optical CT for the readout of 3D dosimeters. The purpose of this paper is to describe the initial evaluation of a newly fabricated laser CT scanner for 3D gel dosimetry which works using the first generation principle. A normoxic PAGAT (Polyacrylamide Gelatin and Tetrakis) gel is used as a dosimeter for this analysis. When a laser passes through the gel phantom, absorption and scattering of photon take place. The optical attenuation coefficient of the laser can be obtained by measuring its intensity after passing through the gel by a sensor. The scanner motion is controlled by a computer program written in Microsoft Visual C++. Reconstruction and data analysis on the irradiated gel phantom is performed by suitable algorithm using Matlab software.

  12. Optical CT evaluation on normoxic polymer gel dosimeter

    International Nuclear Information System (INIS)

    Samuel, E. James Jebaseelan

    2013-01-01

    Optical computed tomography has been shown to be a potentially useful imaging tool for the radiation therapy physicists. In radiation therapy, researchers have used optical CT for the readout of 3D dosimeters. The purpose of this paper is to explicate the initial evaluation of a newly fabricated laser CT scanner for '3D gel dosimetry' which works in the first generation principle. The normoxic PAGAT (Polyacrylamide Gelatin and Tetrakis) gel is used as a dosimeter for this analysis. When laser passes through this gel phantom, absorption and scattering of photon take place. The optical attenuation coefficient of the laser can be obtained by measuring its intensity after passing through the gel by a sensor.The scanner motion is controlled by the program written in Microsoft Visual C++. Reconstruction and data analysis on the irradiated gel phantom is performed by suitable algorithm using Matlab software. (author)

  13. High sensitive radiation detector for radiology dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Valente, M.; Malano, F. [Instituto de Fisica Enrique Gaviola, Oficina 102 FaMAF - UNC, Av. Luis Medina Allende, Ciudad Universitaria, 5000 Cordoba (Argentina); Molina, W.; Vedelago, J., E-mail: valente@famac.unc.edu.ar [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  14. High sensitive radiation detector for radiology dosimetry

    International Nuclear Information System (INIS)

    Valente, M.; Malano, F.; Molina, W.; Vedelago, J.

    2014-08-01

    Fricke solution has a wide range of applications as radiation detector and dosimetry. It is particularly appreciated in terms of relevant comparative advantages, like tissue equivalence when prepared in aqueous media like gel matrix, continuous mapping capability, dose rate recorded and incident direction independence as well as linear dose response. This work presents the development and characterization of a novel Fricke gel system, based on modified chemical compositions making possible its application in clinical radiology. Properties of standard Fricke gel dosimeter for high dose levels are used as starting point and suitable chemical modifications are introduced and carefully investigated in order to attain high resolution for low dose ranges, like those corresponding to radiology interventions. The developed Fricke gel radiation dosimeter system achieves the expected typical dose dependency, actually showing linear response in the dose range from 20 up to 4000 mGy. Systematic investigations including several chemical compositions are carried out in order to obtain a good enough dosimeter response for low dose levels. A suitable composition among those studied is selected as a good candidate for low dose level radiation dosimetry consisting on a modified Fricke solution fixed to a gel matrix containing benzoic acid along with sulfuric acid, ferrous sulfate, xylenol orange and ultra-pure reactive grade water. Dosimeter samples are prepared in standard vials for its in phantom irradiation and further characterization by spectrophotometry measuring visible light transmission and absorbance before and after irradiation. Samples are irradiated by typical kV X-ray tubes and calibrated Farmer type ionization chamber is used as reference to measure dose rates inside phantoms in at vials locations. Once sensitive material composition is already optimized, dose-response curves show significant improvement regarding overall sensitivity for low dose levels. According to

  15. Dosimetry; La dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Le Couteulx, I.; Apretna, D.; Beaugerie, M.F. [Electricite de France (EDF), 75 - Paris (France)] [and others

    2003-07-01

    Eight articles treat the dosimetry. Two articles evaluate the radiation doses in specific cases, dosimetry of patients in radiodiagnosis, three articles are devoted to detectors (neutrons and x and gamma radiations) and a computer code to build up the dosimetry of an accident due to an external exposure. (N.C.)

  16. Characteristics of a commercially available film digitizer and their significance for film dosimetry

    International Nuclear Information System (INIS)

    Mersseman, B.; De Wagter, C.

    1998-01-01

    Dosimetric detectors used in high-energy photon radiation dosimetry mainly perform a zero- or one-dimensional measurement. These low-dimensional methods are not always adequate in the context of conformal radiotherapy. Therefore, two-dimensional film dosimetry has attracted attention. We studied a 12-bit CCD-based film digitizer (Vidar VXR-12) with regard to accurate film dosimetry. We investigated the stability, linearity, noise, effects of aberrant light scatter and built-in conversion tables. A digitizing resolution of 75 dpi and a digitizing speed of 20 ms/line result in an optimal signal-to-noise ratio. At optical densities above 2.0, the reading accuracy of the digitizer is limited by noise. The results of various experiments prove both the capabilities and limitations of the digitizer studied. We also propose a method to acquire and process film data using such a digitizer. (author)

  17. Characterization of long-term dose stability of N-isopropylacrylamide polymer gel dosimetry

    International Nuclear Information System (INIS)

    Chang, Y.J.; Central Taiwan University of Science and Technology, Taichung City, Taiwan, ROC; Chen, C.H.; Hsieh, B.T.

    2014-01-01

    In this study, the detailed characteristics, including spatial uniformity, dose distributions, inter-batch variability, reproducibility, and long-term temporal stability, of N-isopropylacrylamide (NIPAM) polymer gel dosimeter were investigated. A commercial 10x fast optical computed tomography scanner (OCTOPUS TM -10×, MGS Research, Inc., Madison, CT, USA) was used to measure NIPAM polymer gel dosimeter. A cylindrical NIPAM gel phantom that measured 10 cm × 10 cm was irradiated via a single-field treatment plan with a field size of 4 cm × 4 cm. The maximum standard deviation of spatial uniformity for NIPAM gel was less than 0.29 %. The average standard deviation among the three batches of gel dosimeters was less than 1 %. The gamma pass rate could reach as high as 96.76 % when a 3 % dose difference and a 3 mm dose-to-agreement criteria were used. The long-term measurement of irradiated NIPAM gel dosimeter indicated that the dose maps attained a gradually stable value 15 h post-irradiation and remained stable until 72 h post-irradiation. The gamma pass rate could achieve a maximum value between 24 and 72 h post-irradiation. The edge enhancement effect that occurred around the irradiated region was observed 72 h post-irradiation. Thus, the results from this study suggest that NIPAM gel dosimeter should be measured approximately 24 h post-irradiation to reduce the occurrence of the edge enhancement effect. (author)

  18. Correlation of acidic and basic carrier ampholyte and immobilized pH gradient two-dimensional gel electrophoresis patterns based on mass spectrometric protein identification

    DEFF Research Database (Denmark)

    Nawrocki, A; Larsen, Martin Røssel; Podtelejnikov, A V

    1998-01-01

    Separation of proteins on either carrier ampholyte-based or immobilized pH gradient-based two-dimensional (2-D) gels gives rise to electrophoretic patterns that are difficult to compare visually. In this paper we have used matrix-assisted laser desorption/ionization mass spectrometry (MALDI......-MS) to determine the identities of 335 protein spots in these two 2-D gel systems, including a substantial number of basic proteins which had never been identified before. Proteins that were identified in both gel systems allowed us to cross-reference the gel patterns. Vector analysis of these cross...

  19. Characterization and identification of early proteins in Chlamydia trachomatis serovar L2 by two-dimensional gel electrophoresis

    DEFF Research Database (Denmark)

    Lundemose, AG; Birkelund, Svend; Larsen, PM

    1990-01-01

    The synthesis of early proteins from Chlamydia trachomatis serovar L2 was analyzed by two-dimensional gel electrophoresis. By pulse-label experiments, the synthesis of seven proteins was observed at 2 to 8 h postinfection before the major outer membrane protein was detected at 8 to 10 h after...

  20. Radiophotoluminescence light scope for high-dose dosimetry

    International Nuclear Information System (INIS)

    Sato, Fuminobu; Zushi, Naoki; Sakiyama, Tomoki; Kato, Yushi; Murata, Isao; Shimizu, Kikuo; Yamamoto, Takayoshi; Iida, Toshiyuki

    2015-01-01

    A radiophotoluminescence (RPL) light scope is a remote-sensing technique for measuring in situ the radiation dose in an RPL detector placed at a distance. The RPL light scope is mainly composed of an ultraviolet (UV) pulse laser, telescopic lenses, a photomultiplier tube, and camera modules. In a performance test, some RPL detectors were placed at distances up to 30 m and were illuminated with a pulsed UV laser beam. The photoluminescence responses of the RPL detectors were analyzed using this scope. Their radiation doses were determined from the amplitude of the given component of the photoluminescence responses. The RPL readout could be repeated without fading, and its amplitude exhibited good linearity at a dose ranging from 0.1 to 60 Gy. Furthermore, a two-dimensional distribution of radiation dose was obtained by laser scanning on an RPL detector. It was confirmed that the RPL light scope was a useful remote-sensing tool for high-dose dosimetry. - Highlights: • A radiophotoluminescence (RPL) light scope was developed for high-dose dosimetry. • The RPL light scope has high sensitivity and accuracy in high-dose dosimetry. • Two-dimensional radiation dose distribution was obtained by the RPL light scope.

  1. Proton spectroscopic imaging of polyacrylamide gel dosimeters for absolute radiation dosimetry

    International Nuclear Information System (INIS)

    Murphy, P.S.; Schwarz, A.J.; Leach, M.O.

    2000-01-01

    Proton spectroscopy has been evaluated as a method for quantifying radiation induced changes in polyacrylamide gel dosimeters. A calibration was first performed using BANG-type gel samples receiving uniform doses of 6 MV photons from 0 to 9 Gy in 1 Gy intervals. The peak integral of the acrylic protons belonging to acrylamide and methylenebisacrylamide normalized to the water signal was plotted against absorbed dose. Response was approximately linear within the range 0-7 Gy. A large gel phantom irradiated with three, coplanar 3x3cm square fields to 5.74 Gy at isocentre was then imaged with an echo-filter technique to map the distribution of monomers directly. The image, normalized to the water signal, was converted into an absolute dose map. At the isocentre the measured dose was 5.69 Gy (SD = 0.09) which was in good agreement with the planned dose. The measured dose distribution elsewhere in the sample shows greater errors. A T 2 derived dose map demonstrated a better relative distribution but gave an overestimate of the dose at isocentre of 18%. The data indicate that MR measurements of monomer concentration can complement T 2 -based measurements and can be used to verify absolute dose. Compared with the more usual T 2 measurements for assessing gel polymerization, monomer concentration analysis is less sensitive to parameters such as gel pH and temperature, which can cause ambiguous relaxation time measurements and erroneous absolute dose calculations. (author)

  2. A metrological study of autoradiographs from two-dimensional gel electrophoresis.

    Science.gov (United States)

    Valiron, O; Lefkovits, I; Garderet, P; Steinberg, C

    1984-12-01

    Samples prepared from a single batch of labeled cells were subjected to two-dimensional gel electrophoresis and autoradiography. Three factors were varied: total quantity of protein, quantity of labeled protein, and exposure time. The mean background absorbance of the film remained identical (about 0.5 A) for all the treated series, whatever the exposure time and whether or not there were unlabeled proteins in the sample. Hence any spot with a peak A of the same order of magnitude can be seen. The standard deviation was about 0.05 A. Thus, the measurement precision is 2.5% of full scale for digitalization over 0 to 2 A. We derived experimental calibration curves, which are neither linear nor logarithmic because of the film response and which can be used on randomly chosen spots.

  3. Radiation dosimetry using magnetic resonance imaging

    International Nuclear Information System (INIS)

    Olsson, L.E.

    1991-01-01

    A new dosimetry system for 3D dose distribution measurements based on the Fricke dosimeter and magnetic resonance imaging (MRI) has been developed. The dosimeter consists of a ferrous sulphate solution incorporated in an agarose gel, which together constitute the dosimeter gel. The absorbed dose to the gel is measured by means of the proton spin-lattice relaxation rate, 1/T1 in an MR scanner. The dose distribution to an arbitrary slice within a dosimeter gel phantom can thus be determined. The chemical yield of the dosimeter gel is significantly higher than that of the for Fricke solution, and is strongly dependent of the initial ferrous sulphate concentration, assuming that the gel is bubbled with oxygen during preparation. A gel of 1.5 mM [Fe 2+ ] and 50 mM [H 2 SO 4 ] has a sensitivity of 0.108 s -1 Gy -1 and is linear up to 50 Gy. The dosimeter gel has uniform dose response over large volumes. Above 50 mM[H 2 SO 4 ] the yield increases only slightly, but the gel strength decreases and results in gel phantoms with non-uniform dose response. Below 50 mM[H 2 SO 4 ] the sensitivity of the dosimeter falls rapidly due to the decreased relaxivity of the ferric ions. The high chemical yield can be explained by a chain reaction and a reaction scheme is accordingly proposed. The dosimeter gel shows no dependence on dose rate or radiation quality and can be regarded as water-equivalent with respect to the interaction of the radiation. The diffusion coefficient of the ferric ions in the agarose gel is 1.19x10 -2 cm 2 /h. The diffusion blurs the dosimeteric image, but poses only a minor problem if the MR measurements are completed within the first two hours after irradiation. Dose distribution data from external radiation therapy units have been determined using the dosimeter gel and MRI with good accuracy, but the precision is poor, about 5-10%. (au) (84 refs.)

  4. Cu2+-assisted two dimensional charge-mass double focusing gel electrophoresis and mass spectrometric analysis of histone variants.

    Science.gov (United States)

    Zhang, Wenyang; Tang, Xuemei; Ding, Mengjie; Zhong, Hongying

    2014-12-10

    Abundant isoforms and dynamic posttranslational modifications cause the separation and identification of histone variants to be experimentally challenging. To meet this need, we employ two-dimensional electrophoretic gel separation followed by mass spectrometric detection which takes advantage of the chelation of Cu(2+) with amino acid residues exposed on the surfaces of the histone proteins. Acid-extracted rat liver histones were first mixed with CuSO4 solution and then separated in one dimension with triton-acid-urea (TAU) gel electrophoresis and in a second dimension using sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE). The separations result from both the changes in charge and mass upon Cu(2+) chelation. Identities of each separated gel bands were obtained by using matrix-assisted laser desorption-ionization mass spectrometry (MALDI-MS). It was found that the migration of H3 histone isoforms of rat liver is markedly affected by the use of Cu(2+) ions. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Manufacturing of different gel detectors and their calibration for spatial radiation dose measurements

    International Nuclear Information System (INIS)

    Bero, M.

    2008-05-01

    Three types of gel dosemeter have been made and their most important properties for radiation dosimetry were studied. The comparison between the three categories helps to widen knowledge in each of these detectors and to establish a method for the preparation as well as testing of this radiation sensitive materials. Experiments show the technical application possibility for using these gel detectors to measure the spatial radiation dose distribution in the range of doses given for cancer treatment. The experimental results give some important characteristic for the three gel dosemeter used in comparison to that of the traditional dosimetry systems. It also shows the simplicity of manufacturing the dosemeter from low cost materials and its radiation response to ionizing. The relationships between the dosemeter response and the dose rate as well as the radiation energy were also investigated. Important subjects that have been also taken into consideration are the effects of ambient conditions and storage likelihood of the studied materials. Recommendation was made for the use of these materials in practical applications and for handling as well as their long term storage possibility. (author)

  6. Water equivalence of NIPAM based polymer gel dosimeters with enhanced sensitivity for x-ray CT

    Science.gov (United States)

    Gorjiara, Tina; Hill, Robin; Bosi, Stephen; Kuncic, Zdenka; Baldock, Clive

    2013-10-01

    Two new formulations of N-isopropylacrylamide (NIPAM) based three dimensional (3D) gel dosimeters have recently been developed with improved sensitivity to x-ray CT readout, one without any co-solvent and the other one with isopropanol co-solvent. The water equivalence of the NIPAM gel dosimeters was investigated using different methods to calculate their radiological properties including: density, electron density, number of electrons per grams, effective atomic number, photon interaction probabilities, mass attenuation and energy absorption coefficients, electron collisional, radiative and total mass stopping powers and electron mass scattering power. Monte Carlo modelling was also used to compare the dose response of these gel dosimeters with water for kilovoltage and megavoltage x-ray beams and for megavoltage electron beams. We found that the density and electron density of the co-solvent free gel dosimeter are more water equivalent with less than a 2.6% difference compared to a 5.7% difference for the isopropanol gel dosimeter. Both the co-solvent free and isopropanol solvent gel dosimeters have lower effective atomic numbers than water, differing by 2.2% and 6.5%, respectively. As a result, their photoelectric absorption interaction probabilities are up to 6% and 19% different from water, respectively. Compton scattering and pair production interaction probabilities of NIPAM gel with isopropanol differ by up to 10% from water while for the co-solvent free gel, the differences are 3%. Mass attenuation and energy absorption coefficients of the co-solvent free gel dosimeter and the isopropanol gel dosimeter are up to 7% and 19% lower than water, respectively. Collisional and total mass stopping powers of both gel dosimeters differ by less than 2% from those of water. The dose response of the co-solvent free gel dosimeter is water equivalent (with x-ray beams over the energy range 180 keV-18 MV, both gel dosimeters have less than 2% discrepancy with water. For

  7. SU-E-T-753: Three-Dimensional Dose Distributions of Incident Proton Particle in the Polymer Gel Dosimeter and the Radiochromic Gel Dosimeter: A Simulation Study with MCNP Code

    International Nuclear Information System (INIS)

    Park, M; Kim, G; Ji, Y; Kim, K; Park, S; Jung, H

    2015-01-01

    Purpose: The purpose of this study is to estimate the three-dimensional dose distributions in the polymer and the radiochromic gel dosimeter, and to identify the detectability of both gel dosimeters by comparing with the water phantom in case of irradiating the proton particles. Methods: The normoxic polymer gel and the LCV micelle radiochromic gel were used in this study. The densities of polymer and the radiochromic gel dosimeter were 1.024 and 1.005 g/cm 3 , respectively. The dose distributions of protons in the polymer and radiochromic gel were simulated using Monte Carlo radiation transport code (MCNPX, Los Alamos National Laboratory). The shape of phantom irradiated by proton particles was a hexahedron with the dimension of 12.4 × 12.4 × 15.0 cm 3 . The energies of proton beam were 50, 80, and 140 MeV energies were directed to top of the surface of phantom. The cross-sectional view of proton dose distribution in both gel dosimeters was estimated with the water phantom and evaluated by the gamma evaluation method. In addition, the absorbed dose(Gy) was also calculated for evaluating the proton detectability. Results: The evaluation results show that dose distributions in both gel dosimeters at intermediated section and Bragg-peak region are similar with that of the water phantom. At entrance section, however, inconsistencies of dose distribution are represented, compared with water. The relative absorbed doses in radiochromic and polymer gel dosimeter were represented to be 0.47 % and 2.26 % difference, respectively. These results show that the radiochromic gel dosimeter was better matched than the water phantom in the absorbed dose evaluation. Conclusion: The polymer and the radiochromic gel dosimeter show similar characteristics in dose distributions for the proton beams at intermediate section and Bragg-peak region. Moreover the calculated absorbed dose in both gel dosimeters represents similar tendency by comparing with that in water phantom

  8. Protein composition of wheat gluten polymer fractions determined by quantitative two-dimensional gel electrophoresis and tandem mass spectrometry

    Science.gov (United States)

    Flour proteins from the US bread wheat Butte 86 were extracted in 0.5% SDS using a two-step procedure with and without sonication and further separated by size exclusion chromatography into monomeric and polymeric fractions. Proteins in each fraction were analyzed by quantitative two-dimensional gel...

  9. SU-E-T-104: Development of 3 Dimensional Dosimetry System for Gamma Knife

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, K; Kwak, J; Cho, B; Lee, D; Ahn, S [Asan Medical Center, Seoul (Korea, Republic of)

    2014-06-01

    Purpose: The aim of this study was to develop a new 3 dimensional dosimetry system to verify the dosimetric accuracy of Leksell Gamma Knife-Perfexion™ (LGK) (Elekta, Norcross, GA). Methods: We designed and manufactured a lightweight dosimetry instrument to be equipped with the head frame to LGK. It consists of a head phantom, a scintillator, a CCD camera and a step motor. The 10×10 cm2 sheet of Gd2O3;Tb phosphor or Gafchromic EBT3 film was located at the center of the 16 cm diameter hemispherical PMMA, the head phantom. The additional backscatter compensating material of 1 cm thick PMMA plate was placed downstream of the phosphor sheet. The backscatter plate was transparent for scintillation lights to reach the CCD camera with 1200×1200 pixels by 5.2 um pitch. With This equipment, 300 images with 0.2 mm of slice gap were acquired under three collimator setups (4mm, 8mm and 16mm), respectively. The 2D projected doses from 3D distributions were compared with the exposured film dose. Results: As all doses normalized by the maximum dose value in 16 mm setup, the relative differences between the equipment dose and film dose were 0.2% for 4mm collimator and 0.5% for 8mm. The acquisition of 300 images by the equipment took less than 3 minutes. Conclusion: The new equipment was verified to be a good substitute to radiochromic film, with which required more time and resources. Especially, the new methods was considered to provide much convenient and faster solution in the 3D dose acquisition for LGK.

  10. Topics in radiation dosimetry radiation dosimetry

    CERN Document Server

    1972-01-01

    Radiation Dosimetry, Supplement 1: Topics in Radiation Dosimetry covers instruments and techniques in dealing with special dosimetry problems. The book discusses thermoluminescence dosimetry in archeological dating; dosimetric applications of track etching; vacuum chambers of radiation measurement. The text also describes wall-less detectors in microdosimetry; dosimetry of low-energy X-rays; and the theory and general applicability of the gamma-ray theory of track effects to various systems. Dose equivalent determinations in neutron fields by means of moderator techniques; as well as developm

  11. Characterization of royal jelly proteins in both Africanized and European honeybees (Apis mellifera) by two-dimensional gel electrophoresis.

    Science.gov (United States)

    Sano, Osamu; Kunikata, Toshio; Kohno, Keizo; Iwaki, Kanso; Ikeda, Masao; Kurimoto, Masashi

    2004-01-14

    In this study, the proteins contained in royal jelly (RJ) produced by Africanized honeybees and European honeybees (Apis mellifera) haven been analyzed in detail and compared using two-dimensional gel electrophoresis, and the N-terminal amino acid sequence of each spot has been determined. Most spots were assigned to major royal jelly proteins (MRJPs). Remarkable differences were found in the heterogeneity of the MRJPs, in particular MRJP3, in terms of molecular weights and isoelectric points between the two species of RJ. Furthermore, during the determination of the N-terminal amino acid sequence of each spot, for the first time, MRJP4 protein has been identified, the existence of which had been only implied by cloning of its cDNA sequence. The presence of heterogeneous bands of glucose oxidase was also identified. Thus, the results suggest that two-dimensional gel electrophoresis provides a suitable method for the qualitative analysis of the proteins contained in RJ derived from different honeybee species.

  12. Medical radiation dosimetry with radiochromic film

    International Nuclear Information System (INIS)

    Butson, M.J.; Cancer Services, NSW; Cheung, T.; Yu, P.K.N.; Metcalfe, P.

    2004-01-01

    Full text: Photon, electron and proton radiation are used extensively for medical purposes in diagnostic and therapeutic procedures. Dosimetry of these radiation sources can be performed with radiochromic films, devices that have the ability to produce a permanent visible colour change upon irradiation. Within the last ten years, the use of radiochromic films has expanded rapidly in the medical world due to commercial products becoming more readily available, higher sensitivity films and technology advances in imaging which have allowed scientists to use two-dimensional dosimetry more accurately and inexpensively. Radiochromic film dosimeters are now available in formats, which have accurate dose measurement ranges from less than 1 Gy up to many kGy. A relatively energy independent dose response combined with automatic development of radiochromic film products has made these detectors most useful in medical radiation dosimetry. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  13. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Soares, Christopher G.

    2006-01-01

    The object of this paper is to give a new user some practical information on the use of radiochromic films for medical applications. While various aspects of radiochromic film dosimetry for medical applications have been covered in some detail in several other excellent review articles which have appeared in the last few years [Niroomand-Rad, A., Blackwell, C.R., Coursey, B.M., Gall, K.P., McLaughlin, W.L., Meigooni, A.S., Nath, R., Rodgers, J.E., Soares, C.G., 1998. Radiochromic dosimetry: recommendations of the AAPM Radiation Therapy Committee Task Group 55. Med. Phys. 25, 2093-2115; Dempsey, J.F., Low, D.A., Mutic, S., Markman, J., Kirov, A.S., Nussbaum, G.H., Williamson, J.F., 2000. Validation of a precision radiochromic film dosimetry system for quantitative two-dimensional imaging of acute exposure dose distributions. Med. Phys. 27, 2462-2475; Butson, M.J., Yu, P.K.N., Cheung, T., Metcalfe, P., 2003. Radiochromic film for medical radiation dosimetry. Mater. Sci. Eng. R41, 61-120], it is the intent of the present author to present material from a more user-oriented and practical standpoint. That is, how the films work will be stressed much less than how to make the films work well. The strength of radiochromic films is most evident in applications where there is a very high dose gradient and relatively high absorbed dose rates. These conditions are associated with brachytherapy applications, measurement of small fields, and at the edges (penumbra regions) of larger fields

  14. Proteomic study of muscle sarcoplasmic proteins using AUT-PAGE/SDS-PAGE as two-dimensional gel electrophoresis.

    Science.gov (United States)

    Picariello, Gianluca; De Martino, Alessandra; Mamone, Gianfranco; Ferranti, Pasquale; Addeo, Francesco; Faccia, Michele; Spagnamusso, Salvatore; Di Luccia, Aldo

    2006-03-20

    In the present study, an alternative procedure for two-dimensional (2D) electrophoretic analysis in proteomic investigation of the most represented basic muscle water-soluble proteins is suggested. Our method consists of Acetic acid-Urea-Triton polyacrylamide gel (AUT-PAGE) analysis in the first dimension and standard sodium dodecyl sulphate polyacrylamide gel (SDS-PAGE) in the second dimension. Although standard two-dimensional Immobilized pH Gradient-Sodium Dodecyl-Sulphate (2D IPG-SDS) gel electrophoresis has been successfully used to study these proteins, most of the water-soluble proteins are spread on the alkaline part of the 2D map and are poorly focused. Furthermore, the similarity in their molecular weights impairs resolution of the classical approach. The addition of Triton X-100, a non-ionic detergent, into the gel induces a differential electrophoretic mobility of proteins as a result of the formation of mixed micelles between the detergent and the hydrophobic moieties of polypeptides, separating basic proteins with a criterion similar to reversed phase chromatography based on their hydrophobicity. The acid pH induces positive net charges, increasing with the isoelectric point of proteins, thus allowing enhanced resolution in the separation. By using 2D AUT-PAGE/SDS electrophoresis approach to separate water-soluble proteins from fresh pork and from dry-cured products, we could spread proteins over a greater area, achieving a greater resolution than that obtained by IPG in the pH range 3-10 and 6-11. Sarcoplasmic proteins undergoing proteolysis during the ripening of products were identified by Matrix Assisted Laser Desorption/Ionization-Time of Flight (MALDI-ToF) mass spectrometry peptide mass fingerprinting in a easier and more effective way. Two-dimensional AUT-PAGE/SDS electrophoresis has allowed to simplify separation of sarcoplasmic protein mixtures making this technique suitable in the defining of quality of dry-cured pork products by immediate

  15. Structural organization of the human glucocorticoid receptor determined by one- and two-dimensional gel electrophoresis of proteolytic receptor fragments

    International Nuclear Information System (INIS)

    Smith, A.C.; Harmon, J.M.

    1987-01-01

    The structural organization of the steroid-binding protein of the IM-9 cell glucocorticoid receptor was investigated by using one- and two-dimensional gel electrophoresis of proteolytic receptor fragments. One-dimensional sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) of receptor fragments isolated after trypsin digestion of immunopurified [ 3 H]dexamethasone 21-mesylate ([ 3 H]DM-) labeled receptor revealed the presence of a stable 26.5-kilodalton (kDa) steroid-containing non-DNA-binding fragment, derived from a larger, less stable, 29-kDa fragment. The 26.5-kDa tryptic fragment appeared to be completely contained within a 41-kDa, steroid-containing, DNA-binding species isolated after chymotrypsin digestion of the intact protein. Two-dimensional electrophoretic analysis of the [ 3 H]DM-labeled tryptic fragments resolved two 26.5-kDa and two 29-kDa components. This was the same number of isoforms seen in the intact protein, indicating that the charge heterogeneity of the steroid-binding protein is the result of modification within the steroid-containing, non-DNA-binding, 26.5-kDa tryptic fragment. Two-dimensional analysis of the 41-kDa [ 3 H]DM-labeled chymotryptic species revealed a pattern of isoforms more complex than that seen either in the intact protein or in the steroid-containing tryptic fragments. These results suggest that the 41-kDa [ 3 H]DM-labeled species resolved by one-dimensional SDS-PAGE after chymotrypsin digestion may be composed of several distinct proteolytic fragments

  16. Quantitative two-dimensional gel electrophoresis analysis of human fibroblasts transformed by ras oncogenes.

    Science.gov (United States)

    Miller, M J; Maher, V M; McCormick, J J

    1992-11-01

    Quantitative two-dimensional gel electrophoresis was used to compare the cellular protein patterns of a normal foreskin-derived human fibroblasts cell line (LG1) and three immortal derivatives of LG1. One derivative, designated MSU-1.1 VO, was selected for its ability to grow in the absence of serum and is non-tumorigenic in athymic mice. The other two strains were selected for focus-formation following transfection with either Ha-ras or N-ras oncogenes and form high grade malignant tumors. Correspondence and cluster analysis provided a nonbiased estimate of the relative similarity of the different two-dimensional patterns. These techniques separated the gel patterns into three distinct classes: LG1, MSU-1.1 VO, and the ras transformed cell strains. The MSU-1.1 VO cells were more closely related to the parental LG1 than to the ras-transformed cells. The differences between the three classes were primarily quantitative in nature: 16% of the spots demonstrated statistically significant changes (P 2) in the rate of incorporation of radioactive amino acids. The patterns from the two ras-transformed cell strains were similar, and variations in the expression of proteins that occurred between the separate experiments obscured consistent differences between the Ha-ras and N-ras transformed cells. However, while only 9 out of 758 spots were classified as different (1%), correspondence analysis could consistently separate the two ras transformants. One of these spots was five times more intense in the Ha-ras transformed cells than the N-ras.(ABSTRACT TRUNCATED AT 250 WORDS)

  17. Three-dimensional dosimetry in brachytherapy: A MAGAT study

    Energy Technology Data Exchange (ETDEWEB)

    Lin, M.-H. [Department of Family Medicine and Physical Check-up Center, Tainan Hospital Department of Health, Executive Yuan, Taiwan (China); Department of Nursing, National Tainan Institute of Nursing, Taiwan (China); Huang, T.-C. [Department of Biomedical Imaging and Radiological Science, China Medical University, Taiwan (China); Kao, M.-J. [Department of Family Medicine and Physical Check-up Center, Tainan Hospital Department of Health, Executive Yuan, Taiwan (China); Department of Nursing, National Tainan Institute of Nursing, Taiwan (China); Wu, Jay [Department of Radiological Technology, Central Taiwan University of Science and Technology, Taiwan (China); Chen, C.-L. [Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, No. 110, Sec. 1, Chien-Kuo N. Road, South District, Taichung 402, Taiwan (China); Wu, T.-H. [Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, No. 110, Sec. 1, Chien-Kuo N. Road, South District, Taichung 402, Taiwan (China)], E-mail: tung@csmu.edu.tw

    2009-07-15

    This study is to evaluate the influence of using different matrix size of smoothing filter for image post-processing and various slice thickness during MR imaging on dose estimation in Ir-192 HDR brachytherapy via normoxic polymer gel dosimeter. Our results show its sensitive nature in gel dosimeter while changing these parameters, among which the combination of 2 mm slice thickness of MR images and [5x5] smoothing filter are considered the optimal parameters to provide accurate dose estimations and isodose curves.

  18. Three-dimensional dosimetry in brachytherapy: A MAGAT study

    International Nuclear Information System (INIS)

    Lin, M.-H.; Huang, T.-C.; Kao, M.-J.; Wu, Jay; Chen, C.-L.; Wu, T.-H.

    2009-01-01

    This study is to evaluate the influence of using different matrix size of smoothing filter for image post-processing and various slice thickness during MR imaging on dose estimation in Ir-192 HDR brachytherapy via normoxic polymer gel dosimeter. Our results show its sensitive nature in gel dosimeter while changing these parameters, among which the combination of 2 mm slice thickness of MR images and [5x5] smoothing filter are considered the optimal parameters to provide accurate dose estimations and isodose curves.

  19. 9th International Conference on 3D Radiation Dosimetry

    International Nuclear Information System (INIS)

    2017-01-01

    IC3DDose 2016 - 9th International Conference on 3D Radiation Dosimetry Preface It was a great pleasure to welcome participants to IC3DDose 2016, the 9th International Conference on 3D Radiation Dosimetry, held from 7–10 November 2016 in Galveston, Texas. The series of conferences has evolved considerably during its history. At the first conference, DOSGEL’99, the discussion centered around gel dosimetry. Held in Lexington, Kentucky in 1999, it was timed to coincide with the American Association of Physicists in Medicine (AAPM) Annual Meeting in Nashville, Tennessee. It was my honour to organize that first conference, and it was once again my honour to organize the 9th conference in the series now known as IC3DDose which was held in Galveston, Texas. As was the case with recent IC3DDose conferences, the topic has broadened considerably beyond gel dosimetry. Not only have newer 3D volumetric dosimeters appeared on the scene, but novel electronic dosimetry systems and software that generate quasi-3D dose information have also. These changes have tracked advances in radiation oncology as techniques such as IMRT, VMAT, and IGRT have become almost ubiquitous. At the same time, dynamic treatments including gating and tracking now enjoy widespread use. Novel treatment technologies have appeared with perhaps the most disruptive being combined MR imaging-treatment units such as the ViewRay MR-cobalt unit and the Elekta/Philips MR-Linac. The potential benefits offered by 3D dosimetry were explored, compared and evaluated during IC3DDose 2016. Novel and improved readout techniques, some of which take advantage of the contemporary treatment environment and new QA systems and procedures, as well as other aspects of clinical dosimetry were well represented in the program. Over the past several years, the importance of safety in radiation therapy has been highlighted. The benefits of 3D dosimetry in contributing to safe and accurate treatments cannot be overstated. The

  20. Relative and absolute dosimetry of proton therapy beams

    International Nuclear Information System (INIS)

    Mazal, A.; Delacroix, S.; Bridier, A.; Daures, J.; Dolo, J.M.; Nauraye, C.; Ferrand, R.; Cosgrave, V.; Habrand, J.L.

    1995-01-01

    Different codes of practice are in use or under preparation by several groups and national or international societies, concerning the dosimetry of proton beams. In spite of a large number of experiences and the increasing interest on this field, there are still large incertitudes on some of the basic conversion and correction factors to get dose values from different measuring methods. In practice, dose uniformity between centers is searched and encouraged by intercomparisons using standard procedures. We present the characteristics and the results on proton dosimetry intercomparisons using calorimeters, Faraday cups and ion chambers, as well as on the use of other detectors like diodes, radiographic films and TLD. New detectors like diamond, scintillators, radiochromic films, alanine, gels, ... can give new solutions to particular problems, provided their response is not affected at the end of the proton range (higher LET region), and their resolution, range, linearity, cost, ... are well adapted to practical situations. Some examples of special challenges are non interfering measurements during treatments for quality control, in vivo measurements, small beams for stereotactic irradiations, scanned beams and correlations between dosimetry, microdosimetry and radiobiology

  1. Proteome profile of functional mitochondria from human skeletal muscle using one-dimensional gel electrophoresis and HPLC-ESI-MS/MS

    DEFF Research Database (Denmark)

    Lefort, Natalie; Yi, Zhengping; Bowen, Benjamin

    2009-01-01

    were functional as evidenced by their response to carbohydrate and fat-derived fuels. Using one-dimensional gel electrophoresis and HPLC-ESI-MS/MS, 823 unique proteins were detected, and 487 of these were assigned to the mitochondrion, including the newly characterized SIRT5, MitoNEET and RDH13...

  2. Two-dimensional gel electrophoresis data for proteomic profiling of Sporothrix yeast cells

    Directory of Open Access Journals (Sweden)

    Anderson Messias Rodrigues

    2015-03-01

    Full Text Available Sporotrichosis is a chronic infection of the skin and subcutaneous tissues of human and other mammals caused by a complex of cryptic dimorphic fungi in the plant-associated order Ophiostomatales. With major differences between routes of transmission, Sporothrix infections are emerging as new threat in tropical and subtropical areas, particularly in form of outbreaks. The mechanisms underlying the pathogenesis and invasion of Sporothrix spp. are still poorly understood and many virulence factors remain unidentified. In this scenario, a global analysis of proteins expressed by clinical Sporothrix species combined with the identification of seroreactive proteins is overdue. Optimization of sample preparation and electrophoresis conditions are key steps toward reproducibility of gel-based proteomics assays. We provide the data generated using an efficient protocol of protein extraction for rapid and large-scale proteome analysis using two-dimensional gel electrophoresis. The protocol was established and optimized for pathogenic and non-pathogenic Sporothrix spp. including Sporothrix brasiliensis (CBS 132990, Sporothrix schenckii sensu stricto (CBS 132974, Sporothrix globosa (CBS 132922, and Sporothrix mexicana (CBS 120341. The data, supplied in this article, are related to the research article entitled “Immunoproteomic analysis reveals a convergent humoral response signature in the Sporothrix schenckii complex” (Rodrigues et al., 2014 [1].

  3. Meso-Decorated Switching-Knot Gels

    Science.gov (United States)

    Gong, Jin; Sawamura, Kensuke; Makino, Masato; Kabir, M. H.; Furukawa, Hidemitsu

    Gels are a new material having three-dimensional network structures of macromolecules. They possess excellent properties as swellability, high permeability and biocompatibility, and have been applied in various fields of daily life, food, medicine, architecture, and chemistry .In this study, we tried to prepare new multi-functional and high-strength gels by using Meso-Decoration (Meso-Deco), one new method of structure design at intermediate mesoscale. High-performance rigid-rod aromatic polymorphic crystals. The strengthening of gels can be realized by meso-decorating the gels' structure using high-performance polymorphic crystals. New gels with good mechanical properties, novel optical properties and thermal properties are expected to be developed.

  4. Development of a definitive internal dosimetry code

    International Nuclear Information System (INIS)

    Miller, G.; Inkret, W.C.; Schillaci, M.E.

    1996-01-01

    Internal dosimetry may be divided into tow main problems: (1) the forward (scientific) problem of determining biokinetics models that describe how radionuclides are taken into the body, distributed in body tissues, and excreted, and (2) the inverse (mathematical) problem: given the measured amounts in excreta and assuming a biokinetic model, to determine the times and amounts of intakes into the body. The inverse problem of internal dosimetry is, in fact, a generic problem studied in other fields (e.g., image reconstruction, spectral deconvulution, and model parameter fitting). We have developed a code for plutonium internal dosimetry using the maximum entropy method, a method for solving underdetermined inverse problems with a positivity constraint. Within the framework of Bayesian statistics, we believe the definitive approach is to examine the Bayesian posterior probability describing the probability of an intake scenario (X i ) read ( ... ) as open-quotes the set of,close quotes where X i denotes the intake amount that occurs on the with day. For plutonium, for a worker with a long employment history, this is a very high dimensional probability space, since there may be on the order of 10,000 days when intakes may have occurred. Within this high dimensional space, we calculate the mean intake scenario as i > where denotes the expectation value over the posterior probability distribution. Similarly, we calculate uncertainties and other relevant quantities, such as X 2 , as expectation values over the posterior distribution. Thanks to a recent breakthrough in describing the mathematical structure of the intake process (a Poisson sum representation of intakes), we have developed the initial version of a Bayesian expectation-value algorithm for internal dosimetry reconstructions

  5. Use of normoxic polymer gel dosimeters for measuring diagnostic doses on CT scanners

    International Nuclear Information System (INIS)

    Hill, B; Venning, A J; Baldock, C

    2004-01-01

    X-ray CT has been used to evaluate polymer gel dosimeters for dose response in the therapeutic dose range. This method of polymer gel dosimeter evaluation has been shown to be useful for instance in the comparison of complex sterotactic field distributions with treatment plans. Image averaging and subtraction techniques are used for noise reduction in polymer gel dosimeters resulting in the delivery of several CT slices across the polymer gel dosimeters. It was a logical progression to evaluate normoxic polymer gel dosimeters with optimized CT scanning protocols. During these investigations it was found that unirradiated regions in irradiated normoxic polymer gel dosimetry phantoms polymerised possibly as a result of the evaluation using CT. This prompted an investigation of the CT diagnostic dose response of the normoxic polymer gel dosimeter in order to determine the dose contribution when evaluated using a CT scanner. Having established that there was an effect on the normoxic polymer gel dosimeter when evaluating with a CT scanner the suitability of these gels in the determination of CT diagnostic dose measurement was further investigated

  6. Two-dimensional gel proteome reference map of human small intestine

    Directory of Open Access Journals (Sweden)

    Canzonieri Vincenzo

    2009-03-01

    Full Text Available Abstract Background The small intestine is an important human organ that plays a central role in many physiological functions including digestion, absorption, secretion and defense. Duodenal pathologies include, for instance, the ulcer associated to Helicobacter Pylori infection, adenoma and, in genetically predisposed individuals, celiac disease. Alterations in the bowel reduce its capability to absorb nutrients, minerals and fat-soluble vitamins. Anemia and osteopenia or osteoporosis may develop as a consequence of vitamins malabsorption. Adenoma is a benign tumor that has the potential to become cancerous. Adult celiac disease patients present an overall risk of cancer that is almost twice than that found in the general population. These disease processes are not completely known. To date, a two dimensional (2D reference map of proteins expressed in human duodenal tissue is not yet available: the aim of our study was to characterize the 2D protein map, and to identify proteins of duodenal mucosa of adult individuals without duodenal illness, to create a protein database. This approach, may be useful for comparing similar protein samples in different laboratories and for the molecular characterization of intestinal pathologies without recurring to the use of surgical material. Results The enrolled population comprised five selected samples (3 males and 2 females, aged 19 to 42, taken from 20 adult subjects, on their first visit at the gastroenterology unit for a suspected celiac disease, who did not turn to be affected by any duodenal pathology after gastrointestinal and histological evaluations. Proteins extracted from the five duodenal mucosal specimens were singly separated by 2D gel electrophoresis. After image analysis of each 2D gel, 179 protein spots, representing 145 unique proteins, from 218 spots tested, were successfully identified by MALDI-TOF ms analysis. Normalized volumes, for each protein, have been reported for every gel

  7. Three-dimensional printer-generated patient-specific phantom for artificial in vivo dosimetry in radiotherapy quality assurance.

    Science.gov (United States)

    Kamomae, Takeshi; Shimizu, Hidetoshi; Nakaya, Takayoshi; Okudaira, Kuniyasu; Aoyama, Takahiro; Oguchi, Hiroshi; Komori, Masataka; Kawamura, Mariko; Ohtakara, Kazuhiro; Monzen, Hajime; Itoh, Yoshiyuki; Naganawa, Shinji

    2017-12-01

    Pretreatment intensity-modulated radiotherapy quality assurance is performed using simple rectangular or cylindrical phantoms; thus, the dosimetric errors caused by complex patient-specific anatomy are absent in the evaluation objects. In this study, we construct a system for generating patient-specific three-dimensional (3D)-printed phantoms for radiotherapy dosimetry. An anthropomorphic head phantom containing the bone and hollow of the paranasal sinus is scanned by computed tomography (CT). Based on surface rendering data, a patient-specific phantom is formed using a fused-deposition-modeling-based 3D printer, with a polylactic acid filament as the printing material. Radiophotoluminescence glass dosimeters can be inserted in the 3D-printed phantom. The phantom shape, CT value, and absorbed doses are compared between the actual and 3D-printed phantoms. The shape difference between the actual and printed phantoms is less than 1 mm except in the bottom surface region. The average CT value of the infill region in the 3D-printed phantom is -6 ± 18 Hounsfield units (HU) and that of the vertical shell region is 126 ± 18 HU. When the same plans were irradiated, the dose differences were generally less than 2%. These results demonstrate the feasibility of the 3D-printed phantom for artificial in vivo dosimetry in radiotherapy quality assurance. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  8. Background-free, high sensitivity staining of proteins in one- and two-dimensional sodium dodecyl sulfate-polyacrylamide gels using a luminescent ruthenium complex.

    Science.gov (United States)

    Berggren, K; Chernokalskaya, E; Steinberg, T H; Kemper, C; Lopez, M F; Diwu, Z; Haugland, R P; Patton, W F

    2000-07-01

    SYPRO Ruby dye is a permanent stain comprised of ruthenium as part of an organic complex that interacts noncovalently with proteins. SYPRO Ruby Protein Gel Stain provides a sensitive, gentle, fluorescence-based method for detecting proteins in one-dimensional and two-dimensional sodium dodecyl sulfate-polyacrylamide gels. Proteins are fixed, stained from 3h to overnight and then rinsed in deionized water or dilute methanol/acetic acid solution for 30 min. The stain can be visualized using a wide range of excitation sources commonly used in image analysis systems including a 302 nm UV-B transilluminator, 473 nm second harmonic generation (SHG) laser, 488 nm argon-ion laser, 532 nm yttrium-aluminum-garnet (YAG) laser, xenon arc lamp, blue fluorescent light bulb or blue light-emitting diode (LED). The sensitivity of SYPRO Ruby Protein Gel Stain is superior to colloidal Coomassie Brilliant Blue (CBB) stain or monobromobimane labeling and comparable with the highest sensitivity silver or zinc-imidazole staining procedures available. The linear dynamic range of SYPRO Ruby Protein Gel stain extends over three orders of magnitude, which is vastly superior to silver, zinc-imidazole, monobromobimane and CBB stain. The fluorescent stain does not contain superfluous chemicals (formaldehyde, glutaraldehyde, Tween-20) that frequently interfere with peptide identification in mass spectrometry. While peptide mass profiles are severely altered in protein samples prelabeled with monobromobimane, successful identification of proteins by peptide mass profiling using matrix-assisted laser desorption/ionization mass spectrometry was easily performed after protein detection with SYPRO Ruby Protein Gel stain.

  9. How to perform dosimetry with Optical CT

    International Nuclear Information System (INIS)

    Wuu, Cheng-Shie; Xu, Y

    2010-01-01

    Both polymer gels and PRESAGE radiochromic solid dosimeter, in conjunction with optical CT scanning system, have been employed to measure 3-D dose distribution. The 3-D dose maps obtained from these systems can provide a useful tool for dose verification on complex treatments such as IMRT, radiosurgery, and RapidArc. These complex treatments present high dose gradient regions in the boundaries between the target and the surrounding critical organs. Dose accuracy in these areas can be critical, and may affect the treatment. There is a pressing need for a dosimeter that allows for accurate determination of 3-D dose distribution with high spatial resolution. In this paper, performance of polymer gels and PRESAGE dosimeter with optical CT scanning is reviewed and evaluated in terms of their sensitivity calibration, irradiation, optimization of scanning procedures, precision, and accuracy. Clinical applications of optical-CT dosimetry are presented.

  10. High transparent shape memory gel

    Science.gov (United States)

    Gong, Jin; Arai, Masanori; Kabir, M. H.; Makino, Masato; Furukawa, Hidemitsu

    2014-03-01

    Gels are a new material having three-dimensional network structures of macromolecules. They possess excellent properties as swellability, high permeability and biocompatibility, and have been applied in various fields of daily life, food, medicine, architecture, and chemistry. In this study, we tried to prepare new multi-functional and high-strength gels by using Meso-Decoration (Meso-Deco), one new method of structure design at intermediate mesoscale. High-performance rigid-rod aromatic polymorphic crystals, and the functional groups of thermoreversible Diels-Alder reaction were introduced into soft gels as crosslinkable pendent chains. The functionalization and strengthening of gels can be realized by meso-decorating the gels' structure using high-performance polymorphic crystals and thermoreversible pendent chains. New gels with good mechanical properties, novel optical properties and thermal properties are expected to be developed.

  11. Chemical dosimetry principles in high dose dosimetry

    International Nuclear Information System (INIS)

    Mhatre, Sachin G.V.

    2016-01-01

    In radiation processing, activities of principal concern are process validation and process control. The objective of such formalized procedures is to establish documentary evidence that the irradiation process has achieved the desired results. The key element of such activities is inevitably a well characterized reliable dosimetry system that is traceable to recognized national and international dosimetry standards. Only such dosimetry systems can help establish the required documentary evidence. In addition, industrial radiation processing such as irradiation of foodstuffs and sterilization of health careproducts are both highly regulated, in particular with regard to dose. Besides, dosimetry is necessary for scaling up processes from the research level to the industrial level. Thus, accurate dosimetry is indispensable

  12. An Improved 2-Dimensional Gel Electrophoresis Method for Resolving Human Erythrocyte Membrane Proteins.

    Science.gov (United States)

    Kumar, Manoj; Singh, Rajendra; Meena, Anil; Patidar, Bhagwan S; Prasad, Rajendra; Chhabra, Sunil K; Bansal, Surendra K

    2017-01-01

    The 2-dimensional gel electrophoresis (2-DE) technique is widely used for the analysis of complex protein mixtures extracted from biological samples. It is one of the most commonly used analytical techniques in proteomics to study qualitative and quantitative protein changes between different states of a cell or an organism (eg, healthy and diseased), conditionally expressed proteins, posttranslational modifications, and so on. The 2-DE technique is used for its unparalleled ability to separate thousands of proteins simultaneously. The resolution of the proteins by 2-DE largely depends on the quality of sample prepared during protein extraction which increases results in terms of reproducibility and minimizes protein modifications that may result in artifactual spots on 2-DE gels. The buffer used for the extraction and solubilization of proteins influences the quality and reproducibility of the resolution of proteins on 2-DE gel. The purification by cleanup kit is another powerful process to prevent horizontal streaking which occurs during isoelectric focusing due to the presence of contaminants such as salts, lipids, nucleic acids, and detergents. Erythrocyte membrane proteins serve as prototypes for multifunctional proteins in various erythroid and nonerythroid cells. In this study, we therefore optimized the selected major conditions of 2-DE for resolving various proteins of human erythrocyte membrane. The modification included the optimization of conditions for sample preparation, cleanup of protein sample, isoelectric focusing, equilibration, and storage of immobilized pH gradient strips, which were further carefully examined to achieve optimum conditions for improving the quality of protein spots on 2-DE gels. The present improved 2-DE analysis method enabled better detection of protein spots with higher quality and reproducibility. Therefore, the conditions established in this study may be used for the 2-DE analysis of erythrocyte membrane proteins for

  13. Human cellular protein patterns and their link to genome DNA sequence data: usefulness of two-dimensional gel electrophoresis and microsequencing

    DEFF Research Database (Denmark)

    Celis, J E; Rasmussen, H H; Leffers, H

    1991-01-01

    a global approach to the study of the cell. Using the integrated approach offered by 2-dimensional gel protein databases it is now possible to reveal phenotype specific protein (or proteins), to microsequence them, to search for homology with previously identified proteins, to clone the cDNAs, to assign...

  14. Three dimensional dose verification for clinical treatments of small intracranial tumours

    International Nuclear Information System (INIS)

    Taylor, M.L.; Dunn, L.; Kairn, L.; Jenny, J.; Knight, R.; Trapp, J.; Smith, R.; Ackerly, T.

    2010-01-01

    Full text: Cancers of the brain and central nervous system account for 1.6% of new cancers and 1.8% of cancer deaths globally. The highest rates of all developed nations are observed in Australia and New Zealand. There are known complexities associated with dose measurement of very small radiation fields. Here, 3D dosimetric verification of treatments for small intracranial tumours using gel dosimetry was investigated. An anthropomorphic head phantom with a 43 mm diameter and 63 mm long gel container was filled with PAGAT normoxic radiosensitive gel. In this work, we show results for a 12-field stereotactic radiotherapy treatment delivered using a Varian 21EX with BrainLAB mini-multi leaf collimator. The gel was read out using an Octopus-1Q laser optical CT scanner. Generally good agreement was observed between the measured doses and those calculated with the iPlan treatment planning system (pencil beam convolution); see Fig. I. For gamma criteria of 5%/5 mm the percentage of gamma values less than unity was 95% above the 80% isodose line, indicating good PTV coverage. For lower isodose regions approaching the boundaries of the container poorer agreement was observed. The feasibility of three-dimensional measurement of small field dose distributions in clinical contexts has been demonstrated. Development of this methodology has the potential to overcome many shortcomings of other dosimetric methods, such as limitations of spatial information (typically one- and two-dimensions), volume-averaging effects and perturbation due to poor mediamatching. (author)

  15. Radiation dosimetry and spectrometry with superheated emulsions

    International Nuclear Information System (INIS)

    D'Errico, Francesco

    2001-01-01

    Detectors based on emulsions of overexpanded halocarbon droplets in tissue equivalent aqueous gels or soft polymers, known as 'superheated drop detectors' or 'bubble (damage) detectors', have been used in radiation detection, dosimetry and spectrometry for over two decades. Recent technological advances have led to the introduction of several instruments for individual and area monitoring: passive integrating meters based on the optical or volumetric registration of the bubbles, and active counters detecting bubble nucleations acoustically. These advances in the instrumentation have been matched by the progress made in the production of stable and well-specified emulsions of superheated droplets. A variety of halocarbons are employed in the formulation of the detectors, and this permits a wide range of applications. In particular, halocarbons with a moderate degree of superheat, i.e. a relatively small difference between their operating temperature and boiling point, can be used in neutron dosimetry and spectrometry since they are only nucleated by energetic heavy ions such as those produced by fast neutrons. More recently, halocarbons with an elevated degree of superheat have been utilised to produce emulsions that nucleate with much smaller energy deposition and detect low linear energy transfer radiations, such as photons and electrons. This paper reviews the detector physics of superheated emulsions and their applications in radiation measurements, particularly in neutron dosimetry and spectrometry

  16. 100 years of solid state dosimetry and radiation protection dosimetry

    International Nuclear Information System (INIS)

    Bartlett, David T.

    2008-01-01

    The use of solid state detectors in radiation dosimetry has passed its 100th anniversary. The major applications of these detectors in radiation dosimetry have been in personal dosimetry, retrospective dosimetry, dating, medical dosimetry, the characterization of radiation fields, and also in microdosimetry and radiobiology research. In this introductory paper for the 15th International Conference, I shall speak of the history of solid state dosimetry and of the radiation measurement quantities that developed at the same time, mention some landmark developments in detectors and applications, speak a bit more about dosimetry and measurement quantities, and briefly look at the past and future

  17. Avoiding acidic region streaking in two-dimensional gel electrophoresis: case study with two bacterial whole cell protein extracts.

    Science.gov (United States)

    Roy, Arnab; Varshney, Umesh; Pal, Debnath

    2014-09-01

    Acidic region streaking (ARS) is one of the lacunae in two-dimensional gel electrophoresis (2DE) of bacterial proteome. This streaking is primarily caused by nucleic acid (NuA) contamination and poses major problem in the downstream processes like image analysis and protein identification. Although cleanup and nuclease digestion are practiced as remedial options, these strategies may incur loss in protein recovery and perform incomplete removal of NuA. As a result, ARS has remained a common observation across publications, including the recent ones. In this work, we demonstrate how ultrasound wave can be used to shear NuA in plain ice-cooled water, facilitating the elimination of ARS in the 2DE gels without the need for any additional sample cleanup tasks. In combination with a suitable buffer recipe, IEF program and frequent paper-wick changing approach, we are able to reproducibly demonstrate the production of clean 2DE gels with improved protein recovery and negligible or no ARS. We illustrate our procedure using whole cell protein extracts from two diverse organisms, Escherichia coli and Mycobacterium smegmatis. Our designed protocols are straightforward and expected to provide good 2DE gels without ARS, with comparable times and significantly lower cost.

  18. Dosimetry methods in boron neutron capture therapy

    Energy Technology Data Exchange (ETDEWEB)

    Gambarini, G.; Artuso, E.; Felisi, M.; Regazzoni, V.; Giove, D. [Universita degli Studi di Milano, Department of Physics, Via Festa del Patrono 7, 20122 Milano (Italy); Agosteo, S.; Barcaglioni, L. [Istituto Nazionale di Fisica Nucleare, Milano (Italy); Campi, F.; Garlati, L. [Politecnico di Milano, Energy Department, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); De Errico, F. [Universita degli Studi di Pisa, Department of Civil and Industrial Engineering, Lungamo Pacinotti 43, 56126 Pisa (Italy); Borroni, M.; Carrara, M. [Fondazione IRCCS Istituto Nazionale Tumori, Medical Physics Unit, Via Venezian 1, 20133 Milano (Italy); Burian, J.; Klupak, V.; Viererbl, L.; Marek, M. [Research Centre Rez, Department of Neutron Physics, 250-68 Husinec-Rez (Czech Republic)

    2014-08-15

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  19. Dosimetry methods in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Gambarini, G.; Artuso, E.; Felisi, M.; Regazzoni, V.; Giove, D.; Agosteo, S.; Barcaglioni, L.; Campi, F.; Garlati, L.; De Errico, F.; Borroni, M.; Carrara, M.; Burian, J.; Klupak, V.; Viererbl, L.; Marek, M.

    2014-08-01

    Dosimetry studies have been carried out at thermal and epithermal columns of Lvr-15 research reactor for investigating the spatial distribution of gamma dose, fast neutron dose and thermal neutron fluence. Two different dosimetry methods, both based on solid state detectors, have been studied and applied and the accuracy and consistency of the results have been inspected. One method is based on Fricke gel dosimeters that are dilute water solutions and have good tissue equivalence for neutrons and also for all the secondary radiations produced by neutron interactions in tissue or water phantoms. Fricke gel dosimeters give the possibility of separating the various dose contributions, i.e. the gamma dose, the fast neutron dose and the dose due to charged particles generated during thermal neutron reactions by isotopes having high cross section, like 10-B. From this last dose, thermal neutron fluence can be obtained by means of the kerma factor. The second method is based on thermoluminescence dosimeters. In particular, the developed method draw advantage from the different heights of the peaks of the glow curve of such phosphors when irradiated with photons or with thermal neutrons. The results show that satisfactory results can be obtained with simple methods, in spite of the complexity of the subject. However, the more suitable dosimeters and principally their utilization and analysis modalities are different for the various neutron beams, mainly depending on the relative intensities of the three components of the neutron field, in particular are different for thermal and epithermal columns. (Author)

  20. Effects of interferon gamma on Chlamydia trachomatis serovar A and L2 protein expression investigated by two-dimensional gel electrophoresis

    DEFF Research Database (Denmark)

    Shaw, A; Christiansen, Gunna; Birkelund, Svend

    1999-01-01

    ]methionine and two-dimensional gel electrophoresis with immobilized pH gradients in order to investigate changes in the protein expression of C. trachomatis serovar A and L2 caused by treatment with IFN-gamma. In contrast to what was observed in C. trachomatis L2, our results showed that, in C. trachomatis A, down...

  1. Spot quantification in two dimensional gel electrophoresis image analysis: comparison of different approaches and presentation of a novel compound fitting algorithm

    Science.gov (United States)

    2014-01-01

    Background Various computer-based methods exist for the detection and quantification of protein spots in two dimensional gel electrophoresis images. Area-based methods are commonly used for spot quantification: an area is assigned to each spot and the sum of the pixel intensities in that area, the so-called volume, is used a measure for spot signal. Other methods use the optical density, i.e. the intensity of the most intense pixel of a spot, or calculate the volume from the parameters of a fitted function. Results In this study we compare the performance of different spot quantification methods using synthetic and real data. We propose a ready-to-use algorithm for spot detection and quantification that uses fitting of two dimensional Gaussian function curves for the extraction of data from two dimensional gel electrophoresis (2-DE) images. The algorithm implements fitting using logical compounds and is computationally efficient. The applicability of the compound fitting algorithm was evaluated for various simulated data and compared with other quantification approaches. We provide evidence that even if an incorrect bell-shaped function is used, the fitting method is superior to other approaches, especially when spots overlap. Finally, we validated the method with experimental data of urea-based 2-DE of Aβ peptides andre-analyzed published data sets. Our methods showed higher precision and accuracy than other approaches when applied to exposure time series and standard gels. Conclusion Compound fitting as a quantification method for 2-DE spots shows several advantages over other approaches and could be combined with various spot detection methods. The algorithm was scripted in MATLAB (Mathworks) and is available as a supplemental file. PMID:24915860

  2. Dosimetry

    International Nuclear Information System (INIS)

    Anon.

    1990-01-01

    The purpose of ionizing radiation dosimetry is the measurement of the physical and biological consequences of exposure to radiation. As these consequences are proportional to the local absorption of energy, the dosimetry of ionizing radiation is based on the measurement of this quantity. Owing to the size of the effects of ionizing radiation on materials in all of these area, dosimetry plays an essential role in the prevention and the control of radiation exposure. Its use is of great importance in two areas in particular where the employment of ionizing radiation relates to human health: radiation protection, and medical applications. Dosimetry is different for various reasons: owing to the diversity of the physical characteristics produced by different kinds of radiation according to their nature (X- and γ-photons, electrons, neutrons,...), their energy (from several keV to several MeV), the orders of magnitude of the doses being estimated (a factor of about 10 5 between diagnostic and therapeutic applications); and the temporal and spatial variation of the biological parameters entering into the calculations. On the practical level, dosimetry poses two distinct yet closely related problems: the determination of the absorbed dose received by a subject exposed to radiation from a source external to his body (external dosimetry); and the determination of the absorbed dose received by a subject owing to the presence within his body of some radioactive substance (internal dosimetry)

  3. Development and dosimetric evaluation of radiochromic PCDA vesicle gel dosimeters

    International Nuclear Information System (INIS)

    Sun, P.; Fu, Y.C.; Hu, J.; Hao, N.; Huang, W.; Jiang, B.

    2016-01-01

    The gel dosimeter has the unique capacity in recording radiation dose distribution in three dimensions (3D), which has the specific advantages in dosimetry measurements where steep dose gradients exist, such as in intensity-modulated radiation therapy (IMRT), brachytherapy and so on. Some 3D dosimeters, such as Fricke gel dosimeters, polymer gel dosimeters, the PRESAGE plastic dosimeters and micelle gel dosimeters have appeared recently. However, there are several disadvantages of these 3D dosimeters limit their application in radiotherapy dose verification. In this study, a novel radiochromic gel dosimeter for 3D dose verification of radiotherapy was developed by dispersing nanovesicles self-assembled by 10,12-pentacosadiynoic acid (PCDA) into the tissue equivalence gel matrix. The characteristics of radiochromic PCDA vesicle gel dosimeters were evaluated. The results indicate that these radiochromic gel dosimeters have good linear dose response to X-ray irradiation in the dose range of 2–100 Gy. In addition, the radiochromic gel dosimeters breakthrough the limitations of the existing gel dosimeters such as diffusion effect, post-radiation effect, and poor forming ability. The response of the gel dosimeter does not show any dose rate dependence, energy dependence and temperature effect, and there was no obvious difference in the gel response between single and cumulative dose of fractional irradiation. Hence, the radiochromic PCDA vesicle gel dosimeters developed in this study could be generally applied to 3D dose verification in radiotherapy. - Highlights: • A novel radiochromic gel dosimeter was developed by dispersing PCDA nanovesicles into the tissue equivalence gel matrix. • This nanovesicle overcomes the dose image blurring caused by the diffusion of monomer molecules. • This nanovesicle limits the polymer chain growth, so as to reduce the post-radiation effect. • The gel matrixes possess excellent tissue equivalence and elastic strength, which

  4. 3-D dose verification for IMRT using optical CT based polymer gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Wuu, C [Department of Radiation Oncology, Columbia University, New York, New York (United States); Xu, Y [Department of Radiation Oncology, Columbia University, New York, New York (United States); Maryanski, M J [Department of Radiation Oncology, Columbia University, New York, New York (United States); MGS Research Inc., Madison, Connecticut (United States)

    2004-01-01

    In this study BANG[reg] polymer gels in conjunction with OCTOPUS{sup TM} optical CT scanner (MGS Research Inc., Madison, CT) was employed to measure the relative 3D dose distribution of an IMRT treatment. Measured relative dose distributions from the gel measurement were compared with those from treatment planning system calculations and EDR2 film measurements with regard to planar dose distributions in axial, coronal, and sagittal orientations.

  5. 3-D dose verification for IMRT using optical CT based polymer gel dosimetry

    International Nuclear Information System (INIS)

    Wuu, C; Xu, Y; Maryanski, M J

    2004-01-01

    In this study BANG[reg] polymer gels in conjunction with OCTOPUS TM optical CT scanner (MGS Research Inc., Madison, CT) was employed to measure the relative 3D dose distribution of an IMRT treatment. Measured relative dose distributions from the gel measurement were compared with those from treatment planning system calculations and EDR2 film measurements with regard to planar dose distributions in axial, coronal, and sagittal orientations

  6. Comparative two-dimensional gel analysis and microsequencing identifies gelsolin as one of the most prominent downregulated markers of transformed human fibroblast and epithelial cells

    DEFF Research Database (Denmark)

    Vandekerckhove, J; Bauw, G; Vancompernolle, K

    1990-01-01

    A systematic comparison of the protein synthesis patterns of cultured normal and transformed human fibroblasts and epithelial cells, using two-dimensional gel protein analysis combined with computerized imaging and data acquisition, identified a 90-kD protein (SSP 5714) as one of the most striking...... downregulated markers typical of the transformed state. Using the information stored in the comprehensive human cellular protein database, we found this protein strongly expressed in several fetal tissues and one of them, epidermis, served as a source for preparative two-dimensional gel electrophoresis. Partial...... and by coelectrophoresis with purified human gelsolin. These results suggest that an important regulatory protein of the microfilament system may play a role in defining the phenotype of transformed human fibroblast and epithelial cells in culture. Udgivelsesdato: 1990-Jul...

  7. Comparative two-dimensional gel analysis and microsequencing identifies gelsolin as one of the most prominent downregulated markers of transformed human fibroblast and epithelial cells

    DEFF Research Database (Denmark)

    Vandekerckhove, J; Bauw, G; Vancompernolle, K

    1990-01-01

    downregulated markers typical of the transformed state. Using the information stored in the comprehensive human cellular protein database, we found this protein strongly expressed in several fetal tissues and one of them, epidermis, served as a source for preparative two-dimensional gel electrophoresis. Partial......A systematic comparison of the protein synthesis patterns of cultured normal and transformed human fibroblasts and epithelial cells, using two-dimensional gel protein analysis combined with computerized imaging and data acquisition, identified a 90-kD protein (SSP 5714) as one of the most striking...... and by coelectrophoresis with purified human gelsolin. These results suggest that an important regulatory protein of the microfilament system may play a role in defining the phenotype of transformed human fibroblast and epithelial cells in culture. Udgivelsesdato: 1990-Jul...

  8. Dosimetry Service

    CERN Multimedia

    2006-01-01

    Cern Staff and Users can now consult their dose records for an individual or an organizational unit with HRT. Please see more information on our web page: http://cern.ch/rp-dosimetry Dosimetry Service is open every morning from 8.30 - 12.00. Closed in the afternoons. We would like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCT's) must always be returned to the Service after the use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel. 7 2155 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  9. Two-dimensional gel electrophoresis and FTIR spectroscopy reveal both forms of yeast plasma membrane H(+)-ATPase in activated and basal-level enzyme preparations

    Czech Academy of Sciences Publication Activity Database

    Lapathitis, Georgios; Tanfani, F.; Kotyk, Arnošt; Bertoli, E.

    2001-01-01

    Roč. 505, č. 1 (2001), s. 155-158 ISSN 0014-5793 R&D Projects: GA ČR GA204/98/0474 Keywords : H+-ATPase * plasma membrane * two-dimensional gel electrophoresis Subject RIV: CE - Biochemistry Impact factor: 3.644, year: 2001

  10. Transport Phenomena in Gel

    Directory of Open Access Journals (Sweden)

    Masayuki Tokita

    2016-05-01

    Full Text Available Gel becomes an important class of soft materials since it can be seen in a wide variety of the chemical and the biological systems. The unique properties of gel arise from the structure, namely, the three-dimensional polymer network that is swollen by a huge amount of solvent. Despite the small volume fraction of the polymer network, which is usually only a few percent or less, gel shows the typical properties that belong to solids such as the elasticity. Gel is, therefore, regarded as a dilute solid because its elasticity is much smaller than that of typical solids. Because of the diluted structure, small molecules can pass along the open space of the polymer network. In addition to the viscous resistance of gel fluid, however, the substance experiences resistance due to the polymer network of gel during the transport process. It is, therefore, of importance to study the diffusion of the small molecules in gel as well as the flow of gel fluid itself through the polymer network of gel. It may be natural to assume that the effects of the resistance due to the polymer network of gel depends strongly on the network structure. Therefore, detailed study on the transport processes in and through gel may open a new insight into the relationship between the structure and the transport properties of gel. The two typical transport processes in and through gel, that is, the diffusion of small molecules due to the thermal fluctuations and the flow of gel fluid that is caused by the mechanical pressure gradient will be reviewed.

  11. Dosimetry system 1986

    International Nuclear Information System (INIS)

    Woolson, William A.; Egbert, Stephen D.; Gritzner, Michael L.

    1987-01-01

    In May 1983, the authors proposed a dosimetry system for use by the Radiation Effects Research Foundation (RERF) that would incorporate the new findings and calculations of the joint United States - Japan working groups on the reassessment of A-bomb dosimetry. The proposed dosimetry system evolved from extensive discussions with RERF personnel, numerous meetings of the scientists from Japan and the United States involved in the dosimetry reassessment research, and requirements expressed by epidemiologists and radiobiologists on the various review panels. The dosimetry system proposed was based on considerations of the dosimetry requirements for the normal work of RERF and for future research in radiobiology, the computerized input data on A-bomb survivors available in the RERF data base, the level of detail, precision, and accuracy of various components of the dosimetric estimates, and the computer resources available at RERF in Hiroshima. These discussions and our own experience indicated that, in light of the expansion of computer and radiation technologies and the desire for more detail in the dosimetry, an entirely new approach to the dosimetry system was appropriate. This resulted in a complete replacement of the T65D system as distinguished from a simpler approach involving a renormalization of T65D parameters to reflect the new dosimetry. The proposed dosimetry system for RERF and the plan for implementation was accepted by the Department of Energy (DOE) Working Group on A-bomb Dosimetry chaired by Dr. R.F. Christy. The dosimetry system plan was also presented to the binational A-bomb dosimetry review groups for critical comment and was discussed at joint US-Japan workshop. A prototype dosimetry system incorporating preliminary dosimetry estimates and applicable to only a limited set of A-bomb survivors was installed on the RERF computer system in the fall of 1984. This system was successfully operated at RERF and provided an initial look at the impact of

  12. Sol-Gel Manufactured Energetic Materials

    Science.gov (United States)

    Simpson, Randall L.; Lee, Ronald S.; Tillotson, Thomas M.; Hrubesh, Lawrence W.; Swansiger, Rosalind W.; Fox, Glenn A.

    2005-05-17

    Sol-gel chemistry is used for the preparation of energetic materials (explosives, propellants and pyrotechnics) with improved homogeneity, and/or which can be cast to near-net shape, and/or made into precision molding powders. The sol-gel method is a synthetic chemical process where reactive monomers are mixed into a solution, polymerization occurs leading to a highly cross-linked three dimensional solid network resulting in a gel. The energetic materials can be incorporated during the formation of the solution or during the gel stage of the process. The composition, pore, and primary particle sizes, gel time, surface areas, and density may be tailored and controlled by the solution chemistry. The gel is then dried using supercritical extraction to produce a highly porous low density aerogel or by controlled slow evaporation to produce a xerogel. Applying stress during the extraction phase can result in high density materials. Thus, the sol-gel method can be used for precision detonator explosive manufacturing as well as producing precision explosives, propellants, and pyrotechnics, along with high power composite energetic materials.

  13. Use of the GEANT4 Monte Carlo to determine three-dimensional dose factors for radionuclide dosimetry

    International Nuclear Information System (INIS)

    Amato, Ernesto; Italiano, Antonio; Minutoli, Fabio; Baldari, Sergio

    2013-01-01

    The voxel-level dosimetry is the most simple and common approach to internal dosimetry of nonuniform distributions of activity within the human body. Aim of this work was to obtain the dose “S” factors (mGy/MBqs) at the voxel level for eight beta and beta–gamma emitting radionuclides commonly used in nuclear medicine diagnostic and therapeutic procedures. We developed a Monte Carlo simulation in GEANT4 of a region of soft tissue as defined by the ICRP, divided into 11×11×11 cubic voxels, 3 mm in side. The simulation used the parameterizations of the electromagnetic interaction optimized for low energy (EEDL, EPDL). The decay of each radionuclide ( 32 P, 90 Y, 99m Tc, 177 Lu, 131 I, 153 Sm, 186 Re, 188 Re) were simulated homogeneously distributed within the central voxel (0,0,0), and the energy deposited in the surrounding voxels was mediated on the 8 octants of the three dimensional space, for reasons of symmetry. The results obtained were compared with those available in the literature. While the iodine deviations remain within 16%, for phosphorus, a pure beta emitter, the agreement is very good for self-dose (0,0,0) and good for the dose to first neighbors, while differences are observed ranging from −60% to +100% for voxels far distant from the source. The existence of significant differences in the percentage calculation of the voxel S factors, especially for pure beta emitters such as 32 P or 90 Y, has already been highlighted by other authors. These data can usefully extend the dosimetric approach based on the voxel to other radionuclides not covered in the available literature

  14. SU-F-T-513: Dosimetric Validation of Spatially Fractionated Radiotherapy Using Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Papanikolaou, P; Watts, L; Kirby, N; Rasmussen, K; Gutierrez, A; Stathakis, S [University of Texas HSC SA, San Antonio, TX (United States); Pappas, E [National and Kapodistrian University of Athens, Athens, Attiki (Greece); Kalaitzakis, G; Maris, T [University Of Crete, Heraklion, Crete (Greece); Pappas, E [Technological Educational Institute Of Athens, Athens, Attiki (Greece)

    2016-06-15

    Purpose: Spatially fractionated radiation therapy, also known as GRID therapy, is used to treat large solid tumors by irradiating the target to a single dose of 10–20Gy through spatially distributed beamlets. We have investigated the use of a 3D gel for dosimetric characterization of GRID therapy. Methods: GRID therapy is an external beam analog of volumetric brachytherapy, whereby we produce a distribution of hot and cold dose columns inside the tumor volume. Such distribution can be produced with a block or by using a checker-like pattern with MLC. We have studied both types of GRID delivery. A cube shaped acrylic phantom was filled with polymer gel and served as a 3D dosimeter. The phantom was scanned and the CT images were used to produce two plans in Pinnacle, one with the grid block and one with the MLC defined grid. A 6MV beam was used for the plan with a prescription of 1500cGy at dmax. The irradiated phantom was scanned in a 3T MRI scanner. Results: 3D dose maps were derived from the MR scans of the gel dosimeter and were found to be in good agreement with the predicted dose distribution from the RTP system. Gamma analysis showed a passing rate of 93% for 5% dose and 2mm DTA scoring criteria. Both relative and absolute dose profiles are in good agreement, except in the peripheral beamlets where the gel measured slightly higher dose, possibly because of the changing head scatter conditions that the RTP is not fully accounting for. Our results have also been benchmarked against ionization chamber measurements. Conclusion: We have investigated the use of a polymer gel for the 3D dosimetric characterization and evaluation of GRID therapy. Our results demonstrated that the planning system can predict fairly accurately the dose distribution for GRID type therapy.

  15. SU-F-T-513: Dosimetric Validation of Spatially Fractionated Radiotherapy Using Gel Dosimetry

    International Nuclear Information System (INIS)

    Papanikolaou, P; Watts, L; Kirby, N; Rasmussen, K; Gutierrez, A; Stathakis, S; Pappas, E; Kalaitzakis, G; Maris, T; Pappas, E

    2016-01-01

    Purpose: Spatially fractionated radiation therapy, also known as GRID therapy, is used to treat large solid tumors by irradiating the target to a single dose of 10–20Gy through spatially distributed beamlets. We have investigated the use of a 3D gel for dosimetric characterization of GRID therapy. Methods: GRID therapy is an external beam analog of volumetric brachytherapy, whereby we produce a distribution of hot and cold dose columns inside the tumor volume. Such distribution can be produced with a block or by using a checker-like pattern with MLC. We have studied both types of GRID delivery. A cube shaped acrylic phantom was filled with polymer gel and served as a 3D dosimeter. The phantom was scanned and the CT images were used to produce two plans in Pinnacle, one with the grid block and one with the MLC defined grid. A 6MV beam was used for the plan with a prescription of 1500cGy at dmax. The irradiated phantom was scanned in a 3T MRI scanner. Results: 3D dose maps were derived from the MR scans of the gel dosimeter and were found to be in good agreement with the predicted dose distribution from the RTP system. Gamma analysis showed a passing rate of 93% for 5% dose and 2mm DTA scoring criteria. Both relative and absolute dose profiles are in good agreement, except in the peripheral beamlets where the gel measured slightly higher dose, possibly because of the changing head scatter conditions that the RTP is not fully accounting for. Our results have also been benchmarked against ionization chamber measurements. Conclusion: We have investigated the use of a polymer gel for the 3D dosimetric characterization and evaluation of GRID therapy. Our results demonstrated that the planning system can predict fairly accurately the dose distribution for GRID type therapy.

  16. Is intraoperative real-time dosimetry in prostate seed brachytherapy predictive of biochemical outcome?

    Directory of Open Access Journals (Sweden)

    Daniel Taussky

    2017-06-01

    Full Text Available Purpose : To analyze intraoperative (IO dosimetry using transrectal ultrasound (TRUS, performed before and after prostate low-dose-rate brachytherapy (LDR-BT, and compare it to dosimetry performed 30 days following the LDR-BT implant (Day 30. Material and methods : A total of 236 patients underwent prostate LDR-BT using 125 I that was performed with a three-dimensional TRUS-guided interactive inverse preplanning system (preimplant dosimetry. After the implant procedure, the TRUS was repeated in the operating room, and the dosimetry was recalculated (postimplant dosimetry and compared to dosimetry on Day 30 computed tomography (CT scans. Area under curve (AUC statistics was used for models predictive of dosimetric parameters at Day 30. Results : The median follow-up for patients without BF was 96 months, the 5-year and 8-year biochemical recurrence (BR-free rate was 96% and 90%, respectively. The postimplant median D 90 was 3.8 Gy lower (interquartile range [IQR], 12.4-0.9, and the V 100 only 1% less (IQR, 2.9-0.2% than the preimplant dosimetry. When comparing the postimplant and the Day 30 dosimetries, the postimplant median D 90 was 9.6 Gy higher (IQR [–] 9.5-30.3 Gy, and the V 100 was 3.2% greater (0.2-8.9% than Day 30 postimplant dosimetry. The variables that best predicted the D 90 of Day 30 was the postimplant D 90 (AUC = 0.62, p = 0.038. None of the analyzed values for IO or Day 30 dosimetry showed any predictive value for BR. Conclusions : Although improving the IO preimplant and postimplant dosimetry improved dosimetry on Day 30, the BR-free rate was not dependent on any dosimetric parameter. Unpredictable factors such as intraprostatic seed migration and IO factors, prevented the accurate prediction of Day 30 dosimetry.

  17. Characterization of the Human Skeletal Muscle Proteome by One-dimensional Gel Electrophoresis and HPLC-ESI-MS/MS

    DEFF Research Database (Denmark)

    Højlund, Kurt; Yi, Zhengping; Hwang, Hyonson

    2008-01-01

    and pathophysiological conditions. However, to date, the number of proteins identified by this approach has been limited, with 107 different proteins being the maximum reported so far. Using a combination of one-dimensional gel electrophoresis and high performance liquid chromatography electrospray ionization tandem...... muscle. Mitochondrial proteins accounted for 22% of all proteins identified, including 55 subunits of the respiratory complexes I-V. Moreover, a number of enzymes involved in endocrine and metabolic signaling pathways as well as calcium homeostasis were identified. These results provide the most...

  18. Protein profile analysis of Malaysian snake venoms by two-dimensional gel electrophoresis

    Directory of Open Access Journals (Sweden)

    J Vejayan

    2010-01-01

    Full Text Available Snake venoms comprise a highly complex mixture of proteins, which requires for their characterization the use of versatile two-dimensional electrophoresis techniques. In the present study, venoms obtained from eight snakes (Ophiophagus hannah, Naja kaouthia, Naja sumatrana, Bungarus fasciatus, Trimeresurus sumatranus, Tropidolaemus wagleri, Enhydrina schistosa and Calloselasma rhodostoma commonly found in Malaysia were separated based on two independent properties, isoelectric point (pI and molecular weight (MW. Many differences in snake venoms at the inter-family, inter-subfamily, inter-genus and inter-species levels were revealed. Notably, proteins from individuals of the Viperidae family - Trimeresurus sumatranus, Tropidolaemus wagleri and Calloselasma rhodostoma - were found to be numerous and scattered by the two-dimensional gel electrophoresis (2DE specifically in regions between 37 and 100 kDa compared to the Elapidae venom proteins. The latter were clustered at the basic and lower molecular mass region (less than 20 kDa. Trains of spots were commonly observed, indicating that these proteins may be derived from post-translational modifications. Ophiophagus hannah (Elapidae revealed a great amount of protein spots in the higher molecular mass range when compared to Enhydrina schistosa, Naja kaouthia, Naja sumatrana and Bungarus fasciatus. Overall 2DE showed large differences in the venom profile of each species, which might be employed as an ancillary tool to the identification of venomous snake species.

  19. Polymer gel measurement of dose homogeneity in the breast: comparing MLC intensity modulation with standard wedged delivery

    International Nuclear Information System (INIS)

    Love, P A; Evans, P M; Leach, M O; Webb, S

    2003-01-01

    Polymer gel dosimetry has been used to measure the radiotherapy dose homogeneity in a breast phantom for two different treatment methods. The first 'standard' method uses two tangential wedged fields while the second method has three static fields shaped by multileaf collimators (MLCs) in addition to the standard wedged fields to create intensity modulated fields. Gel dose distributions from the multileaf modulation treatment show an improved dose uniformity in comparison to the standard treatment with a decreased volume receiving doses over 105%

  20. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

    Energy Technology Data Exchange (ETDEWEB)

    Zeidan, O. A.; Sriprisan, S. I.; Lopatiuk-Tirpak, O.; Kupelian, P. A.; Meeks, S. L.; Hsi, W. C.; Li, Z.; Palta, J. R.; Maryanski, M. J. [M. D. Anderson Cancer Center Orlando, Orlando, Florida 32806 (United States); University of Florida Proton Therapy Institute, Jacksonville, Florida 32206 (United States); MGS Research, Inc., Madison, Connecticut 06443 (United States)

    2010-05-15

    Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

  1. Dosimetric evaluation of a novel polymer gel dosimeter for proton therapy

    International Nuclear Information System (INIS)

    Zeidan, O. A.; Sriprisan, S. I.; Lopatiuk-Tirpak, O.; Kupelian, P. A.; Meeks, S. L.; Hsi, W. C.; Li, Z.; Palta, J. R.; Maryanski, M. J.

    2010-01-01

    Purpose: The aim of this study is to evaluate the dosimetric performance of a newly developed proton-sensitive polymer gel formulation for proton therapy dosimetry. Methods: Using passive scattered modulated and nonmodulated proton beams, the dose response of the gel was assessed. A next-generation optical CT scanner is used as the readout mechanism of the radiation-induced absorbance in the gel medium. Comparison of relative dose profiles in the gel to ion chamber profiles in water is performed. A simple and easily reproducible calibration protocol is established for routine gel batch calibrations. Relative stopping power ratio measurement of the gel medium was performed to ensure accurate water-equivalent depth dose scaling. Measured dose distributions in the gel were compared to treatment planning system for benchmark irradiations and quality of agreement is assessed using clinically relevant gamma index criteria. Results: The dosimetric response of the gel was mapped up to 600 cGy using an electron-based calibration technique. Excellent dosimetric agreement is observed between ion chamber data and gel. The most notable result of this work is the fact that this gel has no observed dose quenching in the Bragg peak region. Quantitative dose distribution comparisons to treatment planning system calculations show that most (>97%) of the gel dose maps pass the 3%/3 mm gamma criterion. Conclusions: This study shows that the new proton-sensitive gel dosimeter is capable of reproducing ion chamber dose data for modulated and nonmodulated Bragg peak beams with different clinical beam energies. The findings suggest that the gel dosimeter can be used as QA tool for millimeter range verification of proton beam deliveries in the dosimeter medium.

  2. SU-E-T-606: Performance of MR-Based 3D FXG Dosimetry for Preclinical Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Welch, M [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Jaffray, D [Department of Medical Biophysics, University of Toronto, Toronto, ON (Canada); Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, ON (Canada); Department of Radiation Oncology, University of Toronto, Toronto, ON (Canada); TECHNA Institute for the Advancement of Technology for Health, Toronto, ON (Canada)

    2015-06-15

    Purpose: Technological advances have revolutionized preclinical radiation research to enable precise radiation delivery in preclinical models. Kilovoltage x-rays and complex geometries in preclinical radiation studies challenge conventional dosimetry methods. Previously developed gel-based dosimetry provides a viable means of accommodating complex geometries and accurately reporting dose at kV energies. This paper will describe the development and evaluation of gel-based ferrous xylenol-orange (FXG) dosimetry using a 7T preclinical imaging system. Methods: To confirm water equivalence, Zeff values were calculated for the FXG material, water and ICRU defined soft tissue. Proton T1 relaxivity response in FXG was measured using a preclinical 7T MR and a small animal irradiator for a dose range of 1–22 Gy. FXG was contained in 50 ml centrifuge tubes and irradiated with a 225 kVp x-ray beam at a nominal dose rate of 2.3 Gy/min. Pre and post irradiation maps of the T1 relaxivity were collected using variable TR spin-echo imaging (TE 6.65 ms; TR 500, 750, 1000, 1500, 2000, 3000 and 5000 ms) with 2 mm thick slices, 0.325 mm/pixel, 3 averages and an acquisition time of 26 minutes. A linear fit to the change in relaxation rate (1/T1) for the delivered doses reported the gel sensitivity in units of ms{sup -1}Gy{sup -1}. Irradiation and imaging studies were repeated using three batches of gel over 72 hrs. Results: FXG has a Zeff of 3.8 for the 225 kVp spectrum used; differing from water and ICRU defined soft tissue by 0.5% and 2.5%, respectively. The average sensitivity for the FXG dosimeter was 31.5 ± 0.7 ms{sup -1}Gy{sup -1} (R{sup 2} = 0.9957) with a y-intercept of −29.4 ± 9.0 ms{sup -1}. Conclusion: Preliminary results for the FXG dosimeter properties, sensitivity, and dose linearity at preclinical energies is promising. Future work will explore anatomically relevant tissue inclusions to test MR performance. Student funding provided by The Terry Fox Foundation

  3. Procedures for two-dimensional electrophoresis of proteins

    Energy Technology Data Exchange (ETDEWEB)

    Tollaksen, S.L.; Giometti, C.S.

    1996-10-01

    High-resolution two-dimensional gel electrophoresis (2DE) of proteins, using isoelectric focusing in the first dimension and sodium dodecyl sulfate/polyacrylamide gel electrophoresis (SDS-PAGE) in the second, was first described in 1975. In the 20 years since those publications, numerous modifications of the original method have evolved. The ISO-DALT system of 2DE is a high-throughput approach that has stood the test of time. The problem of casting many isoelectric focusing gels and SDS-PAGE slab gels (up to 20) in a reproducible manner has been solved by the use of the techniques and equipment described in this manual. The ISO-DALT system of two-dimensional gel electrophoresis originated in the late 1970s and has been modified many times to improve its high-resolution, high-throughput capabilities. This report provides the detailed procedures used with the current ISO-DALT system to prepare, run, stain, and photograph two-dimensional gels for protein analysis.

  4. Identification of cysteine proteases and screening of cysteine protease inhibitors in biological samples by a two-dimensional gel system of zymography and reverse zymography.

    Science.gov (United States)

    Saitoh, Eiichi; Yamamoto, Shinya; Okamoto, Eishiro; Hayakawa, Yoshimi; Hoshino, Takashi; Sato, Ritsuko; Isemura, Satoko; Ohtsubo, Sadami; Taniguchi, Masayuki

    2007-11-18

    We have developed a two-dimensional (2D-) gel system of zymography and reverse zymography for the detection and characterization of proteases and protease inhibitors. Isoelectric focusing (IEF) agarose gels with pH gradients were employed for separation in the first-dimension and sodium dodecyl sulfate (SDS)-polyacrylamide gel copolymerized with gelatin used for the second dimension. Proteases and protease inhibitors separated by IEF gel were applied on the second gel without trichloroacetic acid (TCA) fixation. Protease activity in the 2D-gel was visualized as transparent spots where gelatin substrate was digested after commassie brilliant blue (CBB) staining. Some of the transparent spots from the skin mucus extract of rainbow trout were determined to be a cysteine protease through use of E-64 or CA-074. In the reverse zymography technique, the gel was incubated with papain solution at 37 degrees C for 18 h. Cysteine protease inhibitors from broad bean seeds were detected as clear blue spots after CBB staining. The amino (N-) terminal sequences of four papain inhibitor spots thus detected were demonstrated to be identical to that of favin beta chain, a broad bean lectin. Taken together, our system can be considered to be an efficient technique for discovering and characterizing new proteases and protease inhibitors in biological samples. This is the first report describing a 2D-gel system of zymography and reverse zymography.

  5. Diffusion simulation of ferric ions in dosemeter Fricke-gel with variable diffusion coefficient

    International Nuclear Information System (INIS)

    Milani, Caio Jacob; Bevilacqua, Joyce da Silva; Rodrigues Junior, Orlando

    2014-01-01

    Dosimetry using dosimeters Fricke-xylenol-Gel (FXG) allows confirmation and better understanding of radiotherapy treatments. The technique involves the evaluation of volumes irradiated by magnetic resonance imaging (MRI) or CT-optical. In both cases, the time spent between the irradiation and measurement is an important factor that directly influences the results. The quality of the images can be compromised by the mobility of ferric ions (Fe 3+), formed during the interaction of radiation with matter, increasing the uncertainty in determining the isodose. In this work, we simulated the dynamic involving ferric ions formed in one irradiated region irradiated in a two-dimensional domain with a variable diffusion coefficient. This phenomenon is modeled by a differential equation and solved numerically by an efficient algorithm that generalizes the Crank-Nicolson method. The stability and consistency of the method guarantee the convergence of the numerical solution for a predefined tolerance based in the choice of discretization steps of time and space. Different continuous functions were chosen to represent the diffusion coefficient and graphical views of the phenomenon are presented for a better understanding of the process

  6. SU-E-CAMPUS-T-05: Validation of High-Resolution 3D Patient QA for Proton Pencil Beam Scanning and IMPT by Polymer Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Cardin, A; Avery, S; Ding, X; Kassaee, A; Lin, L [University of Pennsylvania, Philadelphia, PA (United States); Maryanski, M [MGS Research, Inc., Madison, CT (United States)

    2014-06-15

    Purpose: Validation of high-resolution 3D patient QA for proton pencil beam scanning and IMPT by polymer gel dosimetry. Methods: Four BANG3Pro polymer gel dosimeters (manufactured by MGS Research Inc, Madison, CT) were used for patient QA at the Robert's Proton Therapy Center (RPTC, Philadelphia, PA). All dosimeters were sealed in identical thin-wall Pyrex glass spheres. Each dosimeter contained a set of markers for 3D registration purposes. The dosimeters were mounted in a consistent and reproducible manner using a custom build holder. Two proton pencil beam scanning plans were designed using Varian Eclipse™ treatment planning system: 1) A two-field intensity modulated proton therapy (IMPT) plan and 2) one single field uniform dose (SFUD) plan. The IMPT fields were evaluated as a composite plan and individual fields, the SFUD plan was delivered as a single field plan.Laser CT scanning was performed using the manufacturer's OCTOPUS-IQ axial transmission laser CT scanner using a 1 mm slice thickness. 3D registration, analysis, and OD/cm to absorbed dose calibrations were perfomed using DICOM RT-Dose and CT files, and software developed by the manufacturer. 3D delta index, a metric equivalent to the gamma tool, was used for dose comparison. Results: Very good agreement with single IMPT fields and with SFUD was obtained. Composite IMPT fields had a less satisfactory agreement. The single fields had 3D delta index passing rates (3% dose difference, 3 mm DTA) of 98.98% and 94.91%. The composite 3D delta index passing rate was 80.80%. The SFUD passing rate was 93.77%. Required shifts of the dose distributions were less than 4 mm. Conclusion: A formulation of the BANG3Pro polymer gel dosimeter, suitable for 3D QA of proton patient plans is established and validated. Likewise, the mailed QA analysis service provided by the manufacturer is a practical option when required resources are unavailable. We fully disclose that the subject of this research regards a

  7. Neutron personnel dosimetry

    International Nuclear Information System (INIS)

    Griffith, R.V.

    1981-01-01

    The current state-of-the-art in neutron personnel dosimetry is reviewed. Topics covered include dosimetry needs and alternatives, current dosimetry approaches, personnel monitoring devices, calibration strategies, and future developments

  8. Gel properties and interactions of Mesona blumes polysaccharide-soy protein isolates mixed gel: The effect of salt addition.

    Science.gov (United States)

    Wang, Wenjie; Shen, Mingyue; Liu, Suchen; Jiang, Lian; Song, Qianqian; Xie, Jianhua

    2018-07-15

    Effect of different salt ions on the gel properties and microstructure of Mesona blumes polysaccharide (MBP)-soy protein isolates (SPI) mixed gels were investigated. Sodium and calcium ions were chosen to explore their effects on the rheological behavior and gel properties of MBP-SPI mixed gels were evaluated by using rheological, X-ray diffraction, protein solubility determination, and microstructure analysis. Results showed that the addition of salt ions change the crystalline state of gels system, the crystal of gel was enhanced at low ion concentrations (0.005-0.01 M). The two peaks of gel characteristic at 8.9° and 19.9° almost disappeared at high salt ions concentrations (0.015-0.02 M), and new crystallization peaks appeared at around 30° and 45°. The elasticity, viscosity, gel strength, water holding capacity, and thermal stability of gel were increased at low ion concentration. Results showed that the main interactions which promoted gel formation and maintain the three-dimensional structure of the gel were electrostatic interactions, hydrophobic interactions, and disulfide interactions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Use of the GEANT4 Monte Carlo to determine three-dimensional dose factors for radionuclide dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Amato, Ernesto, E-mail: eamato@unime.it [University of Messina, Department of Biomedical Sciences and of Morphologic and Functional Imaging, Section of Radiological Sciences (Italy); Italiano, Antonio [INFN – Istituto Nazionale di Fisica Nucleare, Gruppo Collegato di Messina (Italy); Minutoli, Fabio; Baldari, Sergio [University of Messina, Department of Biomedical Sciences and of Morphologic and Functional Imaging, Section of Radiological Sciences (Italy)

    2013-04-21

    The voxel-level dosimetry is the most simple and common approach to internal dosimetry of nonuniform distributions of activity within the human body. Aim of this work was to obtain the dose “S” factors (mGy/MBqs) at the voxel level for eight beta and beta–gamma emitting radionuclides commonly used in nuclear medicine diagnostic and therapeutic procedures. We developed a Monte Carlo simulation in GEANT4 of a region of soft tissue as defined by the ICRP, divided into 11×11×11 cubic voxels, 3 mm in side. The simulation used the parameterizations of the electromagnetic interaction optimized for low energy (EEDL, EPDL). The decay of each radionuclide ({sup 32}P, {sup 90}Y, {sup 99m}Tc, {sup 177}Lu, {sup 131}I, {sup 153}Sm, {sup 186}Re, {sup 188}Re) were simulated homogeneously distributed within the central voxel (0,0,0), and the energy deposited in the surrounding voxels was mediated on the 8 octants of the three dimensional space, for reasons of symmetry. The results obtained were compared with those available in the literature. While the iodine deviations remain within 16%, for phosphorus, a pure beta emitter, the agreement is very good for self-dose (0,0,0) and good for the dose to first neighbors, while differences are observed ranging from −60% to +100% for voxels far distant from the source. The existence of significant differences in the percentage calculation of the voxel S factors, especially for pure beta emitters such as {sup 32}P or {sup 90}Y, has already been highlighted by other authors. These data can usefully extend the dosimetric approach based on the voxel to other radionuclides not covered in the available literature.

  10. RapidArc treatment verification in 3D using polymer gel dosimetry and Monte Carlo simulation

    DEFF Research Database (Denmark)

    Ceberg, Sofie; Gagne, Isabel; Gustafsson, Helen

    2010-01-01

    The aim of this study was to verify the advanced inhomogeneous dose distribution produced by a volumetric arc therapy technique (RapidArc™) using 3D gel measurements and Monte Carlo (MC) simulations. The TPS (treatment planning system)-calculated dose distribution was compared with gel measurements...

  11. Two-dimensional gel electrophoresis pattern (pH 6-11) and identification of water-soluble barley seed and malt proteins by mass spectrometry

    DEFF Research Database (Denmark)

    Bak-Jensen, K.S.; Laugesen, S.; Roepstorff, P.

    2004-01-01

    A protocol was established for two-dimensional gel electrophoresis (2-DE) of barley seed and malt proteins in the pH range of 6-11. Proteins extracted from flour in a low-salt buffer were focused after cup-loading onto IPG strips. Successful separation in the second dimension was achieved using...... gradient gels in a horizontal SDS-PAGE system. Silver staining of gels visualized around 380 (seed) and 500 (malt) spots. Thirty-seven different proteins from seeds were identified in 60 spots, among these 46 were visualized also in the malt 2-D pattern. Proteins were identified by peptide mass...... in defence against pathogens (21 spots), 4 in storage, folding, and synthesis of proteins, and in nitrogen metabolism (5 spots), 6 in carbohydrate metabolism (11 spots), and 4 in stress and detoxification (9 spots). Six proteins (7 spots) were not grouped in these categories, and 3 were not ascribed...

  12. Identification of A/sub 1/ macroglobulin and A/sub 2/ macroglobulin in rat serum by a two-dimensional quantitative immunoelectrophoresis with intermediate gel

    Energy Technology Data Exchange (ETDEWEB)

    Chlebovska, K; Chlebovsky, O [Univerzita P.J. Safarika, Kosice (Czechoslovakia). Katedra Vseobecnej Biologie; Simsa, J [Vojensky Lekarsky Vyzkumny a Doskolovaci Ustav J.E. Purkyne, Hradec Kralove (Czechoslovakia)

    1978-08-01

    A/sub 1/ macroglobulin was identified in rat serum by two-dimensional quantitative immunoelectrophoresis with intermediate gel containing monovalent anti-A/sub 1/M rat serum. A second serum macroglobulin A/sub 2/M antigenically related to A/sub 1/M was identified in turpentine-stimulated or irradiated rats.

  13. Dosimetry

    International Nuclear Information System (INIS)

    Rezende, D.A.O. de

    1976-01-01

    The fundamental units of dosimetry are defined, such as exposure rate, absorbed dose and equivalent dose. A table is given of relative biological effectiveness values for the different types of radiation. The relation between the roentgen and rad units is calculated and the concepts of physical half-life, biological half-life and effective half-life are discussed. Referring to internal dosimetry, a mathematical treatment is given to β particle-and γ radiation dosimetry. The absorbed dose is calculated and a practical example is given of the calculation of the exposure and of the dose rate for a gama source [pt

  14. A novel fibrin gel derived from hyaluronic acid-grafted fibrinogen

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Chiung L; Chen, Hui W; Wang, Tzu C; Wang, Yng J, E-mail: wang@ym.edu.tw [Institute of Biomedical Engineering, National Yang Ming University, No. 155, Sec. 2, Li-Nung St., Shih-Pai, Taipei, Taiwan 112 (China)

    2011-04-15

    Fibrinogen is a major plasma protein that forms a three-dimensional fibrin gel upon being activated by thrombin. In this study, we report the synthesis and potential applications of hybrid molecules composed of fibrinogen coupled to the reducing ends of short-chain hyaluronic acids (sHAs) by reductive amination. The grafting of sHAs to fibrinogen was verified by analyzing particle size, zeta potential and gel-electrophoretic mobility of the hybrid molecules. The sHA-fibrinogen hybrid molecules with graft ratios (sHA/fibrinogen) of up to 6.5 retained the ability to form gels in response to thrombin activation. The sHA-fibrin gels were transparent in appearance and exhibited high water content, which were characteristics distinct from those of gels formed by mixtures of sHAs and fibrinogen. The potential applications of the sHA-fibrin gels were evaluated. The sHA-fibrinogen gel with a graft ratio of 3.6 (S3.6F) was examined for its ability to encapsulate and support the differentiation of ATDC5 chondrocyte-like cells. Compared with the fibrinogen-formed gel, cells cultured in the S3.6F gel exhibited increased lacunae formation; moreover, the abundance of cartilaginous extracellular matrix molecules and the expression of chondrocyte marker genes, such as aggrecan, collagen II and Sox9, were also significantly increased. Our data suggest that the three-dimensional gel formed by the sHA-fibrinogen hybrid is a better support than the fibrin gel for chondrogenesis induction.

  15. A novel fibrin gel derived from hyaluronic acid-grafted fibrinogen

    International Nuclear Information System (INIS)

    Yang, Chiung L; Chen, Hui W; Wang, Tzu C; Wang, Yng J

    2011-01-01

    Fibrinogen is a major plasma protein that forms a three-dimensional fibrin gel upon being activated by thrombin. In this study, we report the synthesis and potential applications of hybrid molecules composed of fibrinogen coupled to the reducing ends of short-chain hyaluronic acids (sHAs) by reductive amination. The grafting of sHAs to fibrinogen was verified by analyzing particle size, zeta potential and gel-electrophoretic mobility of the hybrid molecules. The sHA-fibrinogen hybrid molecules with graft ratios (sHA/fibrinogen) of up to 6.5 retained the ability to form gels in response to thrombin activation. The sHA-fibrin gels were transparent in appearance and exhibited high water content, which were characteristics distinct from those of gels formed by mixtures of sHAs and fibrinogen. The potential applications of the sHA-fibrin gels were evaluated. The sHA-fibrinogen gel with a graft ratio of 3.6 (S3.6F) was examined for its ability to encapsulate and support the differentiation of ATDC5 chondrocyte-like cells. Compared with the fibrinogen-formed gel, cells cultured in the S3.6F gel exhibited increased lacunae formation; moreover, the abundance of cartilaginous extracellular matrix molecules and the expression of chondrocyte marker genes, such as aggrecan, collagen II and Sox9, were also significantly increased. Our data suggest that the three-dimensional gel formed by the sHA-fibrinogen hybrid is a better support than the fibrin gel for chondrogenesis induction.

  16. Two dimensional gel electrophoresis using narrow pH 3-5.6 immobilised pH gradient strips identifies potential novel disease biomarkers in plasma or serum

    OpenAIRE

    sprotocols

    2015-01-01

    Authors: Bevin Gangadharan & Nicole Zitzmann ### Abstract Two-dimensional gel electrophoresis (2-DE) is a protein separation technique often used to separate plasma or serum proteins in an attempt to identify novel biomarkers. This protocol describes how to run 2-DE gels using narrow pH 3-5.6 immobilised pH gradient strips to separate 2 mg of serum proteins. pH 3-6 ampholytes are used to enhance the solubility of proteins in this pH range before the serum proteins are separated in the...

  17. Preparation of the FXG gel dosemeter and studying its response for low and medium energy X-rays

    International Nuclear Information System (INIS)

    Bero, M.; Kharita, M. H.

    2008-02-01

    Gel dosimetry method was found to be capable of addressing complicated issues related to dose measurements particularly in modern sophisticated radiotherapy applications. Ferrous-sulphate Xylenol-orange and Gelatin (FXG) radiochromic gel dosemeter is one of the systems used for such applications. Some chemical dosemeters show different response for low and medium energies X-rays in comparison with high energy-photons. The energy and dose rate dependence of the FXG dose response was examined. In addition to the detector response other important dosimetric properties of the system were investigated for different X-ray beam qualities with tube voltages in the range 100 - 300 kv. An orthovoltage X-ray therapy unit was used to irradiate standard sized samples of FXG from different batches for radiation doses in the range 0 - 8 Gy. This work includes in the first stage the preparation of the radiochromic gel dosemeter (FXG) as well as its calibration in gamma radiation field. Furthermore, the stability and reproducibility of measurements were tested. The obtained results were found to be suitable as a basis to carry on the next stage of this study. The second phase was centred about the delivery of radiation doses from X-ray source that has increasing energy and evaluating the gel material properties as a dosemeter in this case, with concentration on finding the changes of the gel material response with the changes in the applied X-ray energy. Therefore establishing the response radiation energy dependence and comparing the measurement results with other results taken from other known dosimetry system such as ion chambers. Experiments shows that the FXG gel detector has a dynamic rage suitable for the dose delivered in radiotherapy treatment; its response as a function of the dose rate is also stable in the range of radiation energies applied.(Author)

  18. Parameters of the labeling of mitogen-activated murine lymphocytes by [35S]methionine for two-dimensional gel electrophoresis. I

    International Nuclear Information System (INIS)

    Kettman, J.R.

    1986-01-01

    Labeling with [ 35 S]methionine at a high specific activity is essential to the facile preparation of 2-dimensional gel electrophoretograms with the analytical 2-dimensional charge-size separation procedure. Mitogen-activated T and B lymphocytes subjected to low methionine concentrations would not proceed through cell cycle. In the case of activated B lymphocytes, the use of fetal bovine serum, dialyzed to lower endogenous methionine concentrations, prevented B cell growth even in the presence of otherwise satisfactory levels of methionine. High concentrations of [ 35 S]methionine induced B cell death, apparently by radiation damage. Despite these problems, good radioautograms and radiofluorograms of 2D electrophoretograms could be prepared by labeling activated B or T cells in bulk with high specific activity [ 35 S]methionine. (Auth.)

  19. Water-equivalence of gel dosimeters for radiology medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Valente, M; Vedelago, J.; Perez, P. [Instituto de Fisica Enrique Gaviola - CONICET, Av. Medina Allende s/n, Ciudad Universitaria, X5000HUA, Cordoba (Argentina); Chacon, D.; Mattea, F. [Universidad Nacional de Cordoba, FAMAF, Laboratorio de Investigacion e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Av. Medina Allende s/n, Ciudad Universitaria, X5000HUA Cordoba (Argentina); Velasquez, J., E-mail: valente@famaf.unc.edu.ar [ICOS Inmunomedica, Lago Puyehue 01745, Temuco (Chile)

    2017-10-15

    International dosimetry protocols are based on determinations of absorbed dose to water. Ideally, the phantom material should be water equivalent; that is, it should have the same absorption and scatter properties as water. This study presents theoretical, experimental and Monte Carlo modeling of water-equivalence of Fricke and polymer (NIPAM, PAGAT and itaconic acid ITABIS) gel dosimeters. Mass and electronic densities along with effective atomic number were calculated by means of theoretical approaches. Samples were scanned by standard computed tomography and high-resolution micro computed tomography. Photon mass attenuation coefficients and electron stopping powers were examined by Monte Carlo simulations. Theoretical, Monte Carlo and experimental results confirmed good water-equivalence for all gel dosimeters. Overall variations with respect to water in the low energy radiology range (up to 130 k Vp) were found to be less than 3% in average. (Author)

  20. Water-equivalence of gel dosimeters for radiology medical imaging

    International Nuclear Information System (INIS)

    Valente, M; Vedelago, J.; Perez, P.; Chacon, D.; Mattea, F.; Velasquez, J.

    2017-10-01

    International dosimetry protocols are based on determinations of absorbed dose to water. Ideally, the phantom material should be water equivalent; that is, it should have the same absorption and scatter properties as water. This study presents theoretical, experimental and Monte Carlo modeling of water-equivalence of Fricke and polymer (NIPAM, PAGAT and itaconic acid ITABIS) gel dosimeters. Mass and electronic densities along with effective atomic number were calculated by means of theoretical approaches. Samples were scanned by standard computed tomography and high-resolution micro computed tomography. Photon mass attenuation coefficients and electron stopping powers were examined by Monte Carlo simulations. Theoretical, Monte Carlo and experimental results confirmed good water-equivalence for all gel dosimeters. Overall variations with respect to water in the low energy radiology range (up to 130 k Vp) were found to be less than 3% in average. (Author)

  1. An investigation of the chemical stability of a monomer/polymer gel dosimeter

    International Nuclear Information System (INIS)

    De Deene, Y.; De Wagter, C.; De Neve, W.; Achten, E.

    2000-01-01

    The aim of this work is to investigate the temporal stability of a polyacrylamide gelatin hydrogel used for 3D monomer/polymer gel dosimetry techniques involving different methods of analysis. Long-term instabilities for a similar gel have recently been reported, but differ markedly from those described in this work. Two kinds of long-term instabilities are described. One affects the slope of the dose-R 2 plot and is related to post-irradiation polymerization of the comonomer/polymer aggregates. It is observed that post-irradiation polymerization only lasts 12 hours after irradiation. The other instability affects the intercept of the dose-R 2 plot, lasts for up to 30 days and is related to the gelation process of gelatin. Further studies were performed on gelatin gels of varying compositions to obtain a better understanding of the molecular mechanism that causes the instability due to gelation. The studies included observations of the spin-spin and spin-lattice relaxation rates in combination with diffusion measurements and optical measurements. It is shown that the heating history during the manufacture of the gel affects the absolute R 2 value of the gel but not its variation. The findings presented in this study may help in producing more stable and reproducible monomer/polymer gel dosimeters. (author)

  2. Analysis of glycoprotein-derived oligosaccharides in glycoproteins detected on two-dimensional gel by capillary electrophoresis using on-line concentration method.

    Science.gov (United States)

    Kamoda, Satoru; Nakanishi, Yasuharu; Kinoshita, Mitsuhiro; Ishikawa, Rika; Kakehi, Kazuaki

    2006-02-17

    Capillary electrophoresis (CE) is an effective tool to analyze carbohydrate mixture derived from glycoproteins with high resolution. However, CE has a disadvantage that a few nanoliters of a sample solution are injected to a narrow capillary. Therefore, we have to prepare a sample solution of high concentration for CE analysis. In the present study, we applied head column field-amplified sample stacking method to the analysis of N-linked oligosaccharides derived from glycoprotein separated by two-dimensional gel electrophoresis. Model studies demonstrated that we achieved 60-360 times concentration effect on the analysis of carbohydrate chains labeled with 3-aminobenzoic acid (3-AA). The method was applied to the analysis of N-linked oligosaccharides from glycoproteins separated and detected on PAGE gel. Heterogeneity of alpha1-acid glycoprotein (AGP), i.e. glycoforms, was examined by 2D-PAGE and N-linked oligosaccharides were released by in-gel digestion with PNGase F. The released oligosaccharides were derivatized with 3-AA and analyzed by CE. The results showed that glycoforms having lower pI values contained a larger amount of tetra- and tri-antennary oligosaccharides. In contrast, glycoforms having higher pI values contained bi-antennary oligosaccharides abundantly. The result clearly indicated that the spot of a glycoprotein glycoform detected by Coomassie brilliant blue staining on 2D-PAGE gel is sufficient for quantitative profiling of oligosaccharides.

  3. Avoiding acidic region streaking in two-dimensional gel ...

    Indian Academy of Sciences (India)

    Supplementary figure 6. 2DE gel images ... Number of acidic streaks. Fedyunin et al. 2012. 4.02. 6. Zuo et al. 2000. 2.54. 9. Valenete et ... CE, 3rd 2009 Proteasomal protein degradation in ... Nandakumar MP, Shen J, Raman B and Marten MR.

  4. Innovation and the future of advanced dosimetry: 2D to 5D

    Science.gov (United States)

    Oldham, Mark

    2017-05-01

    Recent years have witnessed a remarkable evolution in the techniques, capabilities and applications of 3D dosimetry. Initially the goal was simple: to innovate new techniques capable of comprehensively measuring and verifying exquisitely intricate dose distributions from a paradigm changing emerging new therapy, IMRT. Basic questions emerged: how well were treatment planning systems modelling the complex delivery, and how could treatments be verified for safe use on patients? Since that time, equally significant leaps of innovation have continued in the technology of treatment delivery. In addition, clinical practice has been transformed by the addition of on-board imaging capabilities, which tend to hypo-fractionation strategies and margin reduction. The net result is a high stakes treatment setting where the clinical morbidity of any unintended treatment deviation is exacerbated by the combination of highly conformal dose distributions given with reduced margins with fractionation regimens unfriendly to healthy tissue. Not surprisingly this scenario is replete with challenges and opportunities for new and improved dosimetry systems. In particular tremendous interest exists in comprehensive 3D dosimetry systems, and systems that can resolve the dose in moving structures (4D) and even in deforming structures (5D). Despite significant progress in the capability of multi-dimensional dosimetry systems, it is striking that true 3D dosimetry systems are today largely found in academic institutions or specialist clinics. The reasons will be explored. We will highlight innovations occurring both in treatment delivery and in advanced dosimetry methods designed to verify them, and explore current and future opportunities for advanced dosimetry tools in clinical practice and translational research.

  5. Role of gel dosimeters in boron neutron capture therapy

    International Nuclear Information System (INIS)

    Khajeali, Azim; Farajollahi, Ali Reza; Khodadadi, Roghayeh; Kasesaz, Yaser; Khalili, Assef

    2015-01-01

    Gel dosimeters have acquired a unique status in radiotherapy, especially with the advent of the new techniques in which there is a need for three-dimensional dose measurement with high spatial resolution. One of the techniques in which the use of gel dosimeters has drawn the attention of the researchers is the boron neutron capture therapy. Exploring the history of gel dosimeters, this paper sets out to study their role in the boron neutron capture therapy dosimetric process. - Highlights: • Gel dosimeters have been investigated. • Conventional dosimetric proses of BNCT has been investigated. • Role of gel dosimeters in BNCT has been investigated

  6. Comparative gel-based phosphoproteomics in response to signaling molecules

    KAUST Repository

    Marondedze, Claudius; Lilley, Kathryn S.; Thomas, Ludivine

    2013-01-01

    The gel-based proteomics approach is a valuable technique for studying the characteristics of proteins. This technique has diverse applications ranging from analysis of a single protein to the study of the total cellular proteins. Further, protein quality and to some extent distribution can be first assessed by means of one-dimensional gel electrophoresis and then more informatively, for comparative analysis, using the two-dimensional gel electrophoresis technique. Here, we describe how to take advantage of the availability of fluorescent dyes to stain for a selective class of proteins on the same gel for the detection of both phospho- and total proteomes. This enables the co-detection of phosphoproteins as well as total proteins from the same gel and is accomplished by utilizing two different fluorescent stains, the ProQ-Diamond, which stains only phosphorylated proteins, and Sypro Ruby, which stains the entire subset of proteins. This workflow can be applied to gain insights into the regulatory mechanisms induced by signaling molecules such as cyclic nucleotides through the quantification and subsequent identification of responsive phospho- and total proteins. © Springer Science+Business Media New York 2013.

  7. Comparative gel-based phosphoproteomics in response to signaling molecules

    KAUST Repository

    Marondedze, Claudius

    2013-09-03

    The gel-based proteomics approach is a valuable technique for studying the characteristics of proteins. This technique has diverse applications ranging from analysis of a single protein to the study of the total cellular proteins. Further, protein quality and to some extent distribution can be first assessed by means of one-dimensional gel electrophoresis and then more informatively, for comparative analysis, using the two-dimensional gel electrophoresis technique. Here, we describe how to take advantage of the availability of fluorescent dyes to stain for a selective class of proteins on the same gel for the detection of both phospho- and total proteomes. This enables the co-detection of phosphoproteins as well as total proteins from the same gel and is accomplished by utilizing two different fluorescent stains, the ProQ-Diamond, which stains only phosphorylated proteins, and Sypro Ruby, which stains the entire subset of proteins. This workflow can be applied to gain insights into the regulatory mechanisms induced by signaling molecules such as cyclic nucleotides through the quantification and subsequent identification of responsive phospho- and total proteins. © Springer Science+Business Media New York 2013.

  8. Internal sources dosimetry

    International Nuclear Information System (INIS)

    Savio, Eduardo

    1994-01-01

    The absorbed dose, need of estimation in risk evaluation in the application of radiopharmaceuticals in Nuclear Medicine practice,internal dosimetry,internal and external sources. Calculation methodology,Marinelli model,MIRD system for absorbed dose calculation based on biological parameters of radiopharmaceutical in human body or individual,energy of emitted radiations by administered radionuclide, fraction of emitted energy that is absorbed by target body.Limitation of the MIRD calculation model. A explanation of Marinelli method of dosimetry calculation,β dosimetry. Y dosimetry, effective dose, calculation in organs and tissues, examples. Bibliography .

  9. A safe and efficient method to retrieve mesenchymal stem cells from three-dimensional fibrin gels.

    Science.gov (United States)

    Carrion, Bita; Janson, Isaac A; Kong, Yen P; Putnam, Andrew J

    2014-03-01

    Mesenchymal stem cells (MSCs) display multipotent characteristics that make them ideal for potential therapeutic applications. MSCs are typically cultured as monolayers on tissue culture plastic, but there is increasing evidence suggesting that they may lose their multipotency over time in vitro and eventually cease to retain any resemblance to in vivo resident MSCs. Three-dimensional (3D) culture systems that more closely recapitulate the physiological environment of MSCs and other cell types are increasingly explored for their capacity to support and maintain the cell phenotypes. In much of our own work, we have utilized fibrin, a natural protein-based material that serves as the provisional extracellular matrix during wound healing. Fibrin has proven to be useful in numerous tissue engineering applications and has been used clinically as a hemostatic material. Its rapid self-assembly driven by thrombin-mediated alteration of fibrinogen makes fibrin an attractive 3D substrate, in which cells can adhere, spread, proliferate, and undergo complex morphogenetic programs. However, there is a significant need for simple cost-effective methods to safely retrieve cells encapsulated within fibrin hydrogels to perform additional analyses or use the cells for therapy. Here, we present a safe and efficient protocol for the isolation of MSCs from 3D fibrin gels. The key ingredient of our successful extraction method is nattokinase, a serine protease of the subtilisin family that has a strong fibrinolytic activity. Our data show that MSCs recovered from 3D fibrin gels using nattokinase are not only viable but also retain their proliferative and multilineage potentials. Demonstrated for MSCs, this method can be readily adapted to retrieve any other cell type from 3D fibrin gel constructs for various applications, including expansion, bioassays, and in vivo implantation.

  10. Granular gel support-enabled extrusion of three-dimensional alginate and cellular structures.

    Science.gov (United States)

    Jin, Yifei; Compaan, Ashley; Bhattacharjee, Tapomoy; Huang, Yong

    2016-06-03

    Freeform fabrication of soft structures has been of great interest in recent years. In particular, it is viewed as a critical step toward the grand vision of organ printing--the on-demand design and fabrication of three-dimensional (3D) human organ constructs for implantation and regenerative medicine. The objective of this study is to develop a novel granular gel support material-enabled, two-step gelation-based 'printing-then-gelation' approach to fabricate 3D alginate structures using filament extrusion. Specifically, a granular Carbopol microgel bath holds the ungelled alginate structure being extruded, avoiding the instantaneous gelation of each printed layer as well as resultant surface tension-induced nozzle clogging. Since Carbopol microgels react with multivalent cations, which are needed for alginate crosslinking, gelatin is introduced as a sacrificial material to make an alginate and gelatin bioink for extrusion, which gels thermally (step-one gelation) to initially stabilize the printed structure for removal from Carbopol. Then gelatin is melted and diffused away while alginate is ionically crosslinked in a 37 °C calcium chloride bath (step-two gelation), resulting in an alginate structure. The proposed 'printing-then-gelation' approach works for alginate structure fabrication, and it is also applicable for the printing of cellular constructs and other similar homogeneous soft structures using a two-step or even multi-step approach. The main conclusions are: (1) 0.8% (w/v) Carbopol bath with a neutral pH value may be most suitable for soft structure printing; (2) it is most effective to use a 0.9% (w/v) NaCl solution to facilitate the removal of residual Carbopol; and (3) alginate structures fabricated using the proposed approach demonstrate better mechanical properties than those fabricated using the conventional 'gelation-while-printing' approach.

  11. Dosimetric properties of a radiochromic gel detector for diagnostic X-rays

    International Nuclear Information System (INIS)

    Bero, M.A.

    2007-01-01

    The gel dosimetry method was found to be capable of addressing complicated issues related to dose measurements particularly in modern sophisticated radiotherapy applications. The Ferrous-sulphate Xylenol-orange and Gelatin (FXG) radiochromic gel dosemeter is one of the systems used for such applications. Some chemical dosemeters show different responses for low- and medium-energy X-rays in comparison with high-energy γ-photons. The energy and dose rate dependence of the FXG dose response was examined. In addition to the detector response, other important dosimetric properties of the system were investigated for different X-ray beam qualities with tube voltages in the range 100-300 kV. An orthovoltage X-ray therapy unit was used to irradiate standard sized samples of FXG from different batches for radiation doses in the range 0-20 Gy

  12. Three-dimensional high dose rate dosimetry of electron beams. A combined radiochromic film, EPR and calorimetric dosimetry

    International Nuclear Information System (INIS)

    Secerov, B.; Milosavljevic, B.H.; Bacic, G.; Belgrade Univ.

    2002-01-01

    Complete text of publication follows. Aim. To examine the suitability of radiochromic film (RCF) dosimeters in determining 3D dose distribution from a pulsed electron beam source by comparing their response with alanine EPR dosimetry and calorimetry. Experimental. A FWT-60 radiochromic films (Far West Technology Inc) were used while alanine films were home made. To obtain the dose vs. penetration depth relationship, a stack of 13 films separated by aluminium plates and/or alanine films was placed perpendicular to the electron beam (Febetron, 20 ns, 1.8 MeV, 10 12 Gy/s, dose range up to 100 kGy). RC films were calibrated using 60-Co source and Fricke dosimetry. The absorbance of irradiated films was measured using 2D microdensitometry. Calorimetry was performed with a homemade quasy-adiabatic aluminum calorimeter. Results and Discussion. Microdensitometry of films (5 x 5 cm) enabled the 3D mapping of the entire radiation field with in plane resolution of 0.12 mm. The total dose for each film was obtained by image segmentation to correct for the non-linear response of films. Integrated dose for the entire stack was in good agreement (within 5%) with total absorbed energy as determined with calorimetry. The dose distribution along the beam center was determined using alanine films (1 x 1 cm) and EPR spectroscopy, and again a good agreement with the dose determined by microdensitometry of the central portion of RC films. In conclusion, the results indicate that RC films can be used for determination of 3D dose distribution even at very high dose rates

  13. Techniques for radiation measurements: Micro-dosimetry and dosimetry

    International Nuclear Information System (INIS)

    Waker, A. J.

    2006-01-01

    Experimental Micro-dosimetry is concerned with the determination of radiation quality and how this can be specified in terms of the distribution of energy deposition arising from the interaction of a radiation field with a particular target site. This paper discusses various techniques that have been developed to measure radiation energy deposition over the three orders of magnitude of site-size; nano-meter, micrometer and millimetre, which radiation biology suggests is required to fully account for radiation quality. Inevitably, much of the discussion will concern the use of tissue-equivalent proportional counters and variants of this device, but other technologies that have been studied, or are under development, for their potential in experimental Micro-dosimetry are also covered. Through an examination of some of the quantities used in radiation metrology and dosimetry the natural link with Micro-dosimetric techniques will be shown and the particular benefits of using Micro-dosimetric methods for dosimetry illustrated. (authors)

  14. Thermoluminescence albedo-neutron dosimetry

    International Nuclear Information System (INIS)

    Strand, T.; Storruste, A.

    1986-10-01

    The report discusses neutron detection with respect to dosimetry and compares different thermoluminescent dosimetry materials for neutron dosimetry. Construction and calibration of a thermoluminescence albedo neutron dosemeter, developed by the authors, is described

  15. Meso-decorated self-healing gels: network structure and properties

    Science.gov (United States)

    Gong, Jin; Sawamura, Kensuke; Igarashi, Susumu; Furukawa, Hidemitsu

    2013-04-01

    Gels are a new material having three-dimensional network structures of macromolecules. They possess excellent properties as swellability, high permeability and biocompatibility, and have been applied in various fields of daily life, food, medicine, architecture, and chemistry. In this study, we tried to prepare new multi-functional and high-strength gels by using Meso-Decoration (Meso-Deco), one new method of structure design at intermediate mesoscale. High-performance rigid-rod aromatic polymorphic crystals, and the functional groups of thermoreversible Diels-Alder reaction were introduced into soft gels as crosslinkable pendent chains. The functionalization and strengthening of gels can be realized by meso-decorating the gels' structure using high-performance polymorphic crystals and thermoreversible pendent chains. New gels with good mechanical properties, novel optical properties and thermal properties are expected to be developed.

  16. A phantom production by using 3-dimensional printer and In-vivo dosimetry for a prostate cancer patient

    International Nuclear Information System (INIS)

    Seo, Jung Nam; Na, Jong Eok; Bae, Sun Myung; Jung, Dong Min; Yoon, In Ha; Bae, Jae Bum; Kwack, Jung Won; Baek, Geum Mun

    2015-01-01

    The purpose of this study is to evaluate the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. The phantom is produced to equally describe prostate and rectum based on a 3D volume contour of an actual prostate cancer patient who is treated in Asan Medical Center by using a 3D printer (3D EDISON+, Lokit, Korea). CT(Computed tomography) images of phantom are acquired by computed tomography (Lightspeed CT, GE, USA). By using treatment planning system (Eclipse version 10.0, Varian, USA), treatment planning is established after volume of a prostate cancer patient is compared with volume of the phantom. MOSFET(Metal OXIDE Silicon Field Effect Transistor) is estimated to identify precision and is located in 4 measuring points (bladder, prostate, rectal anterior wall and rectal posterior wall) to analyzed treatment planning and measured value. Prostate volume and rectum volume of prostate cancer patient represent 30.61 cc and 51.19 cc respectively. In case of a phantom, prostate volume and rectum volume represent 31.12 cc and 53.52 cc respectively. A variation of volume between a prostate cancer patient and a phantom is less than 3%. Precision of MOSFET represents less than 3%. It indicates linearity and correlation coefficient indicates from 0.99 - 1.00 depending on dose variation. Each accuracy of bladder, prostate, rectal anterior wall and rectal posterior wall represent 1.4%, 2.6%, 3.7% and 1.5% respectively. In- vivo dosimetry represents entirely less than 5% considering precision of MOSFET. By using a 3D printer, possibility of phantom production based on prostate is verified precision within 3%. effectiveness of In-vivo dosimetry is confirmed from a phantom which is produced by a 3D printer. In-vivo dosimetry is evaluated entirely less than 5% considering precision of MOSFET. Therefore, This study is confirmed the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. It is necessary to additional

  17. A phantom production by using 3-dimensional printer and In-vivo dosimetry for a prostate cancer patient

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jung Nam; Na, Jong Eok; Bae, Sun Myung; Jung, Dong Min; Yoon, In Ha; Bae, Jae Bum; Kwack, Jung Won; Baek, Geum Mun [Dept. of Radiation Oncology, ASAN Medical Center, Seoul (Korea, Republic of)

    2015-06-15

    The purpose of this study is to evaluate the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. The phantom is produced to equally describe prostate and rectum based on a 3D volume contour of an actual prostate cancer patient who is treated in Asan Medical Center by using a 3D printer (3D EDISON+, Lokit, Korea). CT(Computed tomography) images of phantom are acquired by computed tomography (Lightspeed CT, GE, USA). By using treatment planning system (Eclipse version 10.0, Varian, USA), treatment planning is established after volume of a prostate cancer patient is compared with volume of the phantom. MOSFET(Metal OXIDE Silicon Field Effect Transistor) is estimated to identify precision and is located in 4 measuring points (bladder, prostate, rectal anterior wall and rectal posterior wall) to analyzed treatment planning and measured value. Prostate volume and rectum volume of prostate cancer patient represent 30.61 cc and 51.19 cc respectively. In case of a phantom, prostate volume and rectum volume represent 31.12 cc and 53.52 cc respectively. A variation of volume between a prostate cancer patient and a phantom is less than 3%. Precision of MOSFET represents less than 3%. It indicates linearity and correlation coefficient indicates from 0.99 - 1.00 depending on dose variation. Each accuracy of bladder, prostate, rectal anterior wall and rectal posterior wall represent 1.4%, 2.6%, 3.7% and 1.5% respectively. In- vivo dosimetry represents entirely less than 5% considering precision of MOSFET. By using a 3D printer, possibility of phantom production based on prostate is verified precision within 3%. effectiveness of In-vivo dosimetry is confirmed from a phantom which is produced by a 3D printer. In-vivo dosimetry is evaluated entirely less than 5% considering precision of MOSFET. Therefore, This study is confirmed the usefulness of a 3D printed phantom for in-vivo dosimetry of a prostate cancer patient. It is necessary to additional

  18. Exploration of beer proteome using OFFGEL prefractionation in combination with two-dimensional gel electrophoresis with narrow pH range gradients.

    Science.gov (United States)

    Konečná, Hana; Müller, Lukáš; Dosoudilová, Hana; Potěšil, David; Buršíková, Jana; Sedo, Ondrej; Márová, Ivana; Zdráhal, Zbyněk

    2012-03-14

    Two-dimensional gel electrophoresis in combination with mass spectrometry has already been applied successfully to study beer proteome. Due to the abundance of protein Z in beer samples, prefractionation techniques might help to improve beer proteome coverage. Proteins from four lager beers of different origins were separated by two-dimensional electrophoresis (2-DE) followed by tandem mass spectrometric analysis. Initially 52 proteins mostly from Hordeum vulgare (22 proteins) and Saccharomyces species (25 proteins) were identified. Preparative isoelectric focusing by OFFGEL Fractionator was applied prior to 2-DE to improve its resolution power. As a result of this combined approach, a total of 70 beer proteins from Hordeum vulgare (30 proteins), from Saccharomyces species (31 proteins), and from other sources (9 proteins) were identified. Of these, 37 proteins have not been previously reported in beer samples.

  19. Fricke Xylenol Gel characterization at megavoltage radiation energy

    Energy Technology Data Exchange (ETDEWEB)

    Del Lama, Lucas Sacchini, E-mail: lucasdellama@gmail.com [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, DF-FFCLRP/USP, Avenida Bandeirantes, n" o 3900, Monte Alegre, CEP: 14040-901, Ribeirão Preto, SP (Brazil); Petchevist, Paulo César Dias [Oncoville, Centro de Excelência em Radioterapia em Curitiba, Rodovia BR-277, n" o 1437, Ecoville, CEP: 82305-100, Curitiba, PR (Brazil); Almeida, Adelaide de [Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, DF-FFCLRP/USP, Avenida Bandeirantes, n" o 3900, Monte Alegre, CEP: 14040-901, Ribeirão Preto, SP (Brazil)

    2017-03-01

    Accurate determination of absorbed dose is of great importance in every medical application of ionizing radiation, mainly when involving biological tissues. Among different types of dosimeters, the ferrous sulfate chemical solution, known as Fricke solution, can be detached, due to its accuracy, reproducibility and linearity, been used in radiation dosimetry for over 50 years. Besides these characteristics, the Fricke Xylenol Gel (FXG), became one of the most known dosimeters for absorbed dose spatial distribution because of its high spatial resolution. In this work, we evaluated the FXG dosimeter taking into account different preparation recipes, in order to characterize its response in terms of absorbed dose range, linearity, sensitivity and fading.

  20. Fricke Xylenol Gel characterization at megavoltage radiation energy

    International Nuclear Information System (INIS)

    o 3900, Monte Alegre, CEP: 14040-901, Ribeirão Preto, SP (Brazil))" data-affiliation=" (Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, DF-FFCLRP/USP, Avenida Bandeirantes, no 3900, Monte Alegre, CEP: 14040-901, Ribeirão Preto, SP (Brazil))" >Del Lama, Lucas Sacchini; o 1437, Ecoville, CEP: 82305-100, Curitiba, PR (Brazil))" data-affiliation=" (Oncoville, Centro de Excelência em Radioterapia em Curitiba, Rodovia BR-277, no 1437, Ecoville, CEP: 82305-100, Curitiba, PR (Brazil))" >Petchevist, Paulo César Dias; o 3900, Monte Alegre, CEP: 14040-901, Ribeirão Preto, SP (Brazil))" data-affiliation=" (Departamento de Física, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, DF-FFCLRP/USP, Avenida Bandeirantes, no 3900, Monte Alegre, CEP: 14040-901, Ribeirão Preto, SP (Brazil))" >Almeida, Adelaide de

    2017-01-01

    Accurate determination of absorbed dose is of great importance in every medical application of ionizing radiation, mainly when involving biological tissues. Among different types of dosimeters, the ferrous sulfate chemical solution, known as Fricke solution, can be detached, due to its accuracy, reproducibility and linearity, been used in radiation dosimetry for over 50 years. Besides these characteristics, the Fricke Xylenol Gel (FXG), became one of the most known dosimeters for absorbed dose spatial distribution because of its high spatial resolution. In this work, we evaluated the FXG dosimeter taking into account different preparation recipes, in order to characterize its response in terms of absorbed dose range, linearity, sensitivity and fading.

  1. Implementation of a gel dosimeter for dosimetric verification of treatments with RapidArc{sup TM}; Implementacion de un dosimetro en gel para verificacion dosimetrica de tratamientos con RapidArc{sup TM}

    Energy Technology Data Exchange (ETDEWEB)

    Cortes, H.; Vasquez, J. [Centro de Control de Cancer Ltda., Carrera 16A No. 83 A-11, 110911 Bogota (Colombia); Plazas, M., E-mail: hhcortess@unal.edu.co [Universidad Nacional de Colombia, Av. Carrera 30 No. 45, 110911 Bogota (Colombia)

    2014-08-15

    The gel dosimetry represents advantages on other dosimetric systems for its potential of analyzing information in third dimension (3D). This work seeks to find another alternative for the verification of treatments of high complexity like the RapidArc{sup TM}. A gel type Magic was prepared and characterized, which was irradiated with base in a plan of RapidArc{sup TM} calculated in the Treatment Planning System (Tps) Eclipse, using the Anisotropic Analytic Algorithm (Aaa) for a beam with an acceleration potential of 6 MV. The dosimeter was characterized using Magnetic Resonance Images starting from the correlation between the T2 and the dose. The dose distribution curves were analyzed in second dimension (2D) using the program Omni Pro-I mrT and were compared with the curves obtained for the Tps under the approach gamma 2D. The comparison showed that the Gel represents a valid option inside the acceptable ranges for Quality Assurance in radiotherapy. (Author)

  2. Dosimetry Service

    CERN Multimedia

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 72155 http://cern.ch/rp-dosimetry

  3. SU-E-T-70: Commissioning a Multislice CT Scanner for X-Ray CT Polymer Gel Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, H [University of Victoria, Victoria, BC (Australia); UT Southwestern Medical Center, Dallas, TX (United States); Hilts, M [University of Victoria, Victoria, BC (Australia); BC Cancer Agency, Kelowna, BC (Australia); Jirasek, A [University of Victoria, Victoria, BC (Australia)

    2014-06-01

    Purpose: To commission a multislice computed tomography (CT) scanner for fast and reliable readout of radiation therapy (RT) dose distributions using CT polymer gel dosimetry (PGD). Methods: Commissioning was performed for a 16-slice CT scanner using images acquired through a 1L cylinder filled with water. Additional images were collected using a single slice machine for comparison purposes. The variability in CT number associated with the anode heel effect was evaluated and used to define a new slice-by-slice background image subtraction technique. Image quality was assessed for the multislice system by comparing image noise and uniformity to that of the single slice machine. The consistency in CT number across slices acquired simultaneously using the multislice detector array was also evaluated. Finally, the variability in CT number due to increasing x-ray tube load was measured for the multislice scanner and compared to the tube load effects observed on the single slice machine. Results: Slice-by-slice background subtraction effectively removes the variability in CT number across images acquired simultaneously using the multislice scanner and is the recommended background subtraction method when using a multislice CT system. Image quality for the multislice machine was found to be comparable to that of the single slice scanner. Further study showed CT number was consistent across image slices acquired simultaneously using the multislice detector array for each detector configuration of the slice thickness examined. In addition, the multislice system was found to eliminate variations in CT number due to increasing x-ray tube load and reduce scanning time by a factor of 4 when compared to imaging a large volume using a single slice scanner. Conclusion: A multislice CT scanner has been commissioning for CT PGD, allowing images of an entire dose distribution to be acquired in a matter of minutes. Funding support provided by the Natural Sciences and Engineering

  4. Thermoluminescence in medical dosimetry

    International Nuclear Information System (INIS)

    Rivera, T.

    2011-10-01

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  5. Variable transformation of calibration equations for radiation dosimetry

    International Nuclear Information System (INIS)

    Watanabe, Yoichi

    2005-01-01

    For radiation dosimetry, dosimetric equipment must be calibrated by using known doses. The calibration is done to determine an equation that relates the absorbed dose to a physically measurable quantity. Since the calibration equation is accompanied by unavoidable uncertainties, the doses estimated with such equations suffer from inherent uncertainties. We presented mathematical formulation of the calibration when the calibration relation is either linear or nonlinear. We also derived equations for the uncertainty of the estimated dose as a function of the uncertainties of the parameters in the equations and the measured physical quantity. We showed that a dosimeter with a linear calibration equation with zero dose-offset enables us to perform relative dosimetry without calibration data. Furthermore, a linear equation justifies useful data manipulations such as rescaling the dose and changing the dose-offset for comparing dose distributions. Considering that some dosimeters exhibit linear response with a large dose-offset or often nonlinear response, we proposed variable transformations of the measured physical quantity, namely, linear- and log-transformation methods. The proposed methods were tested with Kodak X-Omat V radiographic film and BANG (registered) polymer gel dosimeter. We demonstrated that the variable transformation methods could lead to linear equations with zero dose-offset and could reduce the uncertainty of the estimated dose

  6. A novel methodology for 3D deformable dosimetry.

    Science.gov (United States)

    Yeo, U J; Taylor, M L; Dunn, L; Kron, T; Smith, R L; Franich, R D

    2012-04-01

    Interfraction and intrafraction variation in anatomic structures is a significant challenge in contemporary radiotherapy. The objective of this work is to develop a novel tool for deformable structure dosimetry, using a tissue-equivalent deformable gel dosimeter that can reproducibly simulate targets subject to deformation. This will enable direct measurement of integrated doses delivered in different deformation states, and the verification of dose deforming algorithms. A modified version of the nPAG polymer gel has been used as a deformable 3D dosimeter and phantom to investigate doses delivered to deforming tissue-equivalent geometry. The deformable gel (DEFGEL) dosimeter/phantom is comprised of polymer gel in a latex membrane, moulded (in this case) into a cylindrical geometry, and deformed with an acrylic compressor. Fifteen aluminium fiducial markers (FM) were implanted into DEFGEL phantoms and the reproducibility of deformation was determined via multiple computed tomography (CT) scans in deformed and nondeformed states before and after multiple (up to 150) deformations. Dose was delivered to the DEFGEL phantom in three arrangements: (i) without deformation, (ii) with deformation, and (iii) cumulative exposures with and without deformation, i.e., dose integration. Irradiations included both square field and a stereotactic multiple dynamic arc treatment adapted from a patient plan. Doses delivered to the DEFGEL phantom were read out using cone beam optical CT. Reproducibility was verified by observation of interscan shifts of FM locations (as determined via CT), measured from an absolute reference point and in terms of inter-FM distance. The majority (76%) of points exhibited zero shift, with others shifting by one pixel size consistent with setup error as confirmed with a control sample. Comparison of dose profiles and 2D isodose distributions from the three arrangements illustrated complex spatial redistribution of dose in all three dimensions occurring as

  7. A novel methodology for 3D deformable dosimetry

    International Nuclear Information System (INIS)

    Yeo, U. J.; Taylor, M. L.; Dunn, L.; Kron, T.; Smith, R. L.; Franich, R. D.

    2012-01-01

    Purpose: Interfraction and intrafraction variation in anatomic structures is a significant challenge in contemporary radiotherapy. The objective of this work is to develop a novel tool for deformable structure dosimetry, using a tissue-equivalent deformable gel dosimeter that can reproducibly simulate targets subject to deformation. This will enable direct measurement of integrated doses delivered in different deformation states, and the verification of dose deforming algorithms. Methods: A modified version of the nPAG polymer gel has been used as a deformable 3D dosimeter and phantom to investigate doses delivered to deforming tissue-equivalent geometry. The deformable gel (DEFGEL) dosimeter/phantom is comprised of polymer gel in a latex membrane, moulded (in this case) into a cylindrical geometry, and deformed with an acrylic compressor. Fifteen aluminium fiducial markers (FM) were implanted into DEFGEL phantoms and the reproducibility of deformation was determined via multiple computed tomography (CT) scans in deformed and nondeformed states before and after multiple (up to 150) deformations. Dose was delivered to the DEFGEL phantom in three arrangements: (i) without deformation, (ii) with deformation, and (iii) cumulative exposures with and without deformation, i.e., dose integration. Irradiations included both square field and a stereotactic multiple dynamic arc treatment adapted from a patient plan. Doses delivered to the DEFGEL phantom were read out using cone beam optical CT. Results: Reproducibility was verified by observation of interscan shifts of FM locations (as determined via CT), measured from an absolute reference point and in terms of inter-FM distance. The majority (76%) of points exhibited zero shift, with others shifting by one pixel size consistent with setup error as confirmed with a control sample. Comparison of dose profiles and 2D isodose distributions from the three arrangements illustrated complex spatial redistribution of dose in all

  8. Neutron dosimetry - A review

    Energy Technology Data Exchange (ETDEWEB)

    Baum, J W

    1955-03-29

    This review summarizes information on the following subjects: (1) physical processes of importance in neutron dosimetry; (2) biological effects of neutrons; (3) neutron sources; and (4) instruments and methods used in neutron dosimetry. Also, possible improvements in dosimetry instrumentation are outlined and discussed. (author)

  9. JENDL Dosimetry File

    International Nuclear Information System (INIS)

    Nakazawa, Masaharu; Iguchi, Tetsuo; Kobayashi, Katsuhei; Iwasaki, Shin; Sakurai, Kiyoshi; Ikeda, Yujiro; Nakagawa, Tsuneo.

    1992-03-01

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d, n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form. (author) 76 refs

  10. JENDL Dosimetry File

    Energy Technology Data Exchange (ETDEWEB)

    Nakazawa, Masaharu; Iguchi, Tetsuo [Tokyo Univ. (Japan). Faculty of Engineering; Kobayashi, Katsuhei [Kyoto Univ., Kumatori, Osaka (Japan). Research Reactor Inst.; Iwasaki, Shin [Tohoku Univ., Sendai (Japan). Faculty of Engineering; Sakurai, Kiyoshi; Ikeda, Yujior; Nakagawa, Tsuneo [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1992-03-15

    The JENDL Dosimetry File based on JENDL-3 was compiled and integral tests of cross section data were performed by the Dosimetry Integral Test Working Group of the Japanese Nuclear Data Committee. Data stored in the JENDL Dosimetry File are the cross sections and their covariance data for 61 reactions. The cross sections were mainly taken from JENDL-3 and the covariances from IRDF-85. For some reactions, data were adopted from other evaluated data files. The data are given in the neutron energy region below 20 MeV in both of point-wise and group-wise files in the ENDF-5 format. In order to confirm reliability of the data, several integral tests were carried out; comparison with the data in IRDF-85 and average cross sections measured in fission neutron fields, fast reactor spectra, DT neutron fields and Li(d,n) neutron fields. As a result, it has been found that the JENDL Dosimetry File gives better results than IRDF-85 but there are some problems to be improved in future. The contents of the JENDL Dosimetry File and the results of the integral tests are described in this report. All of the dosimetry cross sections are shown in a graphical form.

  11. Dosimetry Service

    CERN Multimedia

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service - Tel. 7 2155 http://cern.ch/rp-dosimetry

  12. Dosimetry Service

    CERN Multimedia

    Dosimetry Service

    2005-01-01

    Please remember to read your dosimeter at least once a month. Regular read-outs are vital to ensure that your personal dose is periodically monitored. Dosimeters should be read even if you have not visited the controlled areas. Dosimetry Service Tel. 7 2155 http://cern.ch/rp-dosimetry

  13. Applications of Cherenkov Light Emission for Dosimetry in Radiation Therapy

    Science.gov (United States)

    Glaser, Adam Kenneth

    Since its discovery in the 1930's, the Cherenkov effect has been paramount in the development of high-energy physics research. It results in light emission from charged particles traveling faster than the local speed of light in a dielectric medium. The ability of this emitted light to describe a charged particle's trajectory, energy, velocity, and mass has allowed scientists to study subatomic particles, detect neutrinos, and explore the properties of interstellar matter. However, only recently has the phenomenon been considered in the practical context of medical physics and radiation therapy dosimetry, where Cherenkov light is induced by clinical x-ray photon, electron, and proton beams. To investigate the relationship between this phenomenon and dose deposition, a Monte Carlo plug-in was developed within the Geant4 architecture for medically-oriented simulations (GAMOS) to simulate radiation-induced optical emission in biological media. Using this simulation framework, it was determined that Cherenkov light emission may be well suited for radiation dosimetry of clinically used x-ray photon beams. To advance this application, several novel techniques were implemented to realize the maximum potential of the signal, such as time-gating for maximizing the signal to noise ratio (SNR) and Cherenkov-excited fluorescence for generating isotropic light release in water. Proof of concept experiments were conducted in water tanks to demonstrate the feasibility of the proposed method for two-dimensional (2D) projection imaging, three-dimensional (3D) parallel beam tomography, large field of view 3D cone beam tomography, and video-rate dynamic imaging of treatment plans for a number of common radiotherapy applications. The proposed dosimetry method was found to have a number of unique advantages, including but not limited to its non-invasive nature, water-equivalence, speed, high-resolution, ability to provide full 3D data, and potential to yield data in-vivo. Based on

  14. Dosimetry for radiation processing

    DEFF Research Database (Denmark)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both...... and sterilization dosimetry, optichromic dosimeters in the shape of small tubes for food processing, and ESR spectroscopy of alanine for reference dosimetry. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading...

  15. A comprehensive two-dimensional gel protein database of noncultured unfractionated normal human epidermal keratinocytes: towards an integrated approach to the study of cell proliferation, differentiation and skin diseases

    DEFF Research Database (Denmark)

    Celis, J E; Madsen, Peder; Rasmussen, H H

    1991-01-01

    A two-dimensional (2-D) gel database of cellular proteins from noncultured, unfractionated normal human epidermal keratinocytes has been established. A total of 2651 [35S]methionine-labeled cellular proteins (1868 isoelectric focusing, 783 nonequilibrium pH gradient electrophoresis) were resolved...

  16. SU-E-T-675: Remote Dosimetry with a Novel PRESAGE Formulation

    International Nuclear Information System (INIS)

    Mein, S; Juang, T; Malcolm, J; Adamovics, J; Oldham, M

    2015-01-01

    Purpose: 3D-gel dosimetry provides high-resolution treatment validation; however, scanners aren’t widely available. In remote dosimetry, dosimeters are shipped out from a central base institution to a remote site for irradiation, then shipped back for scanning and analysis, affording a convenient service for treatment validation to institutions lacking the necessary equipment and resources. Previous works demonstrated the high-resolution performance and temporal stability of PRESAGE. Here the newest formulation is investigated for remote dosimetry use. Methods: A new formulation of PRESAGE was created with the aim of improved color stability post irradiation. Dose sensitivity was determined by irradiating cuvettes on a Varian Linac (6MV) from 0–15Gy and measuring change in optical density at 633nm. Sensitivity readings were tracked over time in a temperature control study to determine long-term stability. A large volume study was performed to evaluate the accuracy for remote dosimetry. A 1kg dosimeter was pre-scanned, irradiated on-site with an 8Gy 4field box treatment, post-scanned and shipped to Princess Margaret Hospital for remote reading on an identical scanner. Results: Dose sensitivities ranged from 0.0194–0.0295 ΔOD/(Gy*cm)—similar to previous formulations. Post-irradiated cuvettes stored at 10°C retained 100% initial sensitivity over 5 days and 98.6% over 10 weeks while cuvettes stored at room temperature fell to 95.8% after 5 days and 37.4% after 10 weeks. The immediate and 5-day scans of the 4field box dosimeter data was reconstructed, registered to the corresponding eclipse dose-distribution, and compared with analytical tools in CERR. Immediate and 5-day scans looked visually similar. Line profiles revealed close agreement aside from a slight elevation in dose at the edge in the 5-day readout. Conclusion: The remote dosimetry formulation exhibits excellent temporal stability in small volumes. While immediate and 5-day readout scans of large

  17. Alanine dosimetry for clinical applications. Proceedings

    International Nuclear Information System (INIS)

    Anton, M.

    2006-05-01

    The following topics are dealt with: Therapy level alanine dosimetry at the UK Nationational Physical Laboratory, alanine as a precision validation tool for reference dosimetry, composition of alanine pellet dosimeters, the angular dependence of the alanine ESR spectrum, the CIAE alanine dosimeter for radiotherapy level, a correction for temporal evolution effects in alanine dosimetry, next-generation services foe e-traceability to ionization radiation national standards, establishing e-traceability to HIST high-dose measurement standards, alanine dosimetry of dose delivery from clinical accelerators, the e-scan alanine dosimeter reader, alanine dosimetry at ISS, verification of the integral delivered dose for IMRT treatment in the head and neck region with ESR/alanine dosimetry, alanine dosimetry in helical tomotherapy beams, ESR dosimetry research and development at the University of Palermo, lithium formate as a low-dose EPR radiation dosimeter, sensitivity enhancement of alanine/EPR dosimetry. (HSI)

  18. Developments in physical dosimetry and radiation protection; Entwicklungen in der physikalischen Dosimetrie im Strahlenschutz

    Energy Technology Data Exchange (ETDEWEB)

    Fiebich, Martin [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-07-01

    In the frame of physical dosimetry new dose units have been defined: the depth personal dose (equivalent dose in 10 mm depth) and the surface personal dose (equivalent dose in 0.07 mm depth). Physical dosimetry is applied for the determination of occupational radiation exposure, the radiation protected area control, the estimation of radiation exposure of patients during radiotherapy, for quality assurance and in research projects and optimization challenges. Developments have appeared with respect to punctual measuring chambers, eye lens dosimetry, OSL (optically stimulated luminescence) dosimetry, real-time dosimetry and Monte Carlo methods. New detection limits of about 1 micro Gy were reached.

  19. Textbook of dosimetry. 4. ed.

    International Nuclear Information System (INIS)

    Ivanov, V.I.

    1999-01-01

    This textbook of dosimetry is devoted to the students in physics and technical physics of high education institutions, confronted with different application of atomic energy as well as with protection of population and environment against ionizing radiations. Atomic energy is highly beneficial for man but unfortunately incorporates potential dangers which manifest in accidents, the source of which is either insufficient training of the personnel, a criminal negligence or insufficient reliability of the nuclear facilities. The majority of the incident and accident events have had as origin the personnel errors. This was the case with both the 'Three Miles Island' (1979) and Chernobyl (1986) NPP accidents. The dosimetry science acquires a vital significance in accident situations since the data obtained by its procedures are essential in choosing the correct immediate actions, behaviour tactics, orientation of liquidation of accident consequences as well as in ensuring the health of population. An important accent is placed in this manual on clarification of the nature of physical processes taken place in dosimetric detectors, in establishing the relation between radiation field characteristics and the detector response as well as in defining different dosimetric quantities. The terminology and the units of physical quantities is based on the international system of units. The book contains the following 15 chapters: 1. Ionizing radiation field; 2. Radiation doses; 3. Physical bases of gamma radiation dosimetry; 4. Ionization dosimetric detectors; 5. Semiconductor dosimetric detectors; 6. Scintillation detection in the gamma radiation dosimetry; 7. Luminescent methods in dosimetry; 8. The photographic and chemical methods of gamma radiation dosimetry; 9. Neutron dosimetry; 10. Dosimetry of high intensity radiation; 11. Dosimetry of high energy Bremsstrahlung; 12. Measurement of the linear energy transfer; 13. Microdosimetry; 14. Dosimetry of incorporated

  20. Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response

    Energy Technology Data Exchange (ETDEWEB)

    Chain, J N M; McAuley, K B [Department of Chemical Engineering, Queen' s University, Kingston, K7L 3N6 (Canada); Jirasek, A [Department of Physics and Astronomy, University of Victoria, Victoria, V8W 3P6 (Canada); Schreiner, L J, E-mail: kim.mcauley@chee.queensu.ca [Cancer Centre of Southeastern Ontario, Kingston, K7L 5P9 (Canada)

    2011-04-07

    This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to increase the solubility of N, N'-methylenebisacrylamide (Bis) in aqueous solutions from approximately 3% to 5.5% by weight, enabling the manufacture of dosimeters containing up to 19.5%T, which is the total concentration of NIPAM and Bis by weight. Gelatin is shown to have a mild influence on dose sensitivity when gels are imaged using x-ray CT, and a stronger influence when gels are imaged optically. Phantoms that contain only 3% gelatin and 5 mM tetrakis hydroxymethyl phosphonium chloride are sufficiently stiff for dosimetry applications. The best cosolvent-free gel formulation has a dose sensitivity in the linear range ({approx}0.88 H Gy{sup -1}) that is a small improvement compared to the best NIPAM-based gels that incorporate isopropanol as a cosolvent ({approx}0.80 H Gy{sup -1}). This new gel formulation results in enhanced dose resolution ({approx}0.052 Gy) for x-ray CT readout, making clinical applications of this imaging modality more feasible.

  1. Cosolvent-free polymer gel dosimeters with improved dose sensitivity and resolution for x-ray CT dose response

    International Nuclear Information System (INIS)

    Chain, J N M; McAuley, K B; Jirasek, A; Schreiner, L J

    2011-01-01

    This study reports new N-isopropylacrylamide (NIPAM) polymer gel recipes with increased dose sensitivity and improved dose resolution for x-ray CT readout. NIPAM can be used to increase the solubility of N, N'-methylenebisacrylamide (Bis) in aqueous solutions from approximately 3% to 5.5% by weight, enabling the manufacture of dosimeters containing up to 19.5%T, which is the total concentration of NIPAM and Bis by weight. Gelatin is shown to have a mild influence on dose sensitivity when gels are imaged using x-ray CT, and a stronger influence when gels are imaged optically. Phantoms that contain only 3% gelatin and 5 mM tetrakis hydroxymethyl phosphonium chloride are sufficiently stiff for dosimetry applications. The best cosolvent-free gel formulation has a dose sensitivity in the linear range (∼0.88 H Gy -1 ) that is a small improvement compared to the best NIPAM-based gels that incorporate isopropanol as a cosolvent (∼0.80 H Gy -1 ). This new gel formulation results in enhanced dose resolution (∼0.052 Gy) for x-ray CT readout, making clinical applications of this imaging modality more feasible.

  2. Personnel neutron dosimetry

    International Nuclear Information System (INIS)

    Hankins, D.

    1982-04-01

    This edited transcript of a presentation on personnel neutron discusses the accuracy of present dosimetry practices, requirements, calibration, dosemeter types, quality factors, operational problems, and dosimetry for a criticality accident. 32 figs

  3. Implementation of a gel dosimeter for dosimetric verification of treatments with RapidArcTM

    International Nuclear Information System (INIS)

    Cortes, H.; Vasquez, J.; Plazas, M.

    2014-08-01

    The gel dosimetry represents advantages on other dosimetric systems for its potential of analyzing information in third dimension (3D). This work seeks to find another alternative for the verification of treatments of high complexity like the RapidArc TM . A gel type Magic was prepared and characterized, which was irradiated with base in a plan of RapidArc TM calculated in the Treatment Planning System (Tps) Eclipse, using the Anisotropic Analytic Algorithm (Aaa) for a beam with an acceleration potential of 6 MV. The dosimeter was characterized using Magnetic Resonance Images starting from the correlation between the T2 and the dose. The dose distribution curves were analyzed in second dimension (2D) using the program Omni Pro-I mrT and were compared with the curves obtained for the Tps under the approach gamma 2D. The comparison showed that the Gel represents a valid option inside the acceptable ranges for Quality Assurance in radiotherapy. (Author)

  4. Skin dosimetry - radiological protection aspects of skin dosimetry

    International Nuclear Information System (INIS)

    Dennis, J.A.

    1991-01-01

    Following a Workshop in Skin Dosimetry, a summary of the radiological protection aspects is given. Aspects discussed include routine skin monitoring and dose limits, the need for careful skin dosimetry in high accidental exposures, techniques for assessing skin dose at all relevant depths and the specification of dose quantities to be measured by personal dosemeters and the appropriate methods to be used in their calibration. (UK)

  5. Development and evaluation of a phantom for multi-purpose dosimetry in intensity-modulated radiation therapy

    International Nuclear Information System (INIS)

    Jeong, Hae Sun; Kim, Chan Hyeong; Park, Joo Hwan; Han, Young Yih; Kum, O Yeon

    2011-01-01

    A LEGO-type multi-purpose dosimetry phantom was developed for intensity-modulated radiation therapy (IMRT), which requires various types of challenging dosimetry. Polystyrene, polyethylene, polytetrafluoroethylene (PTFE), and polyurethane foam (PU-F) were selected to represent muscle, fat, bone, and lung tissue, respectively, after considering the relevant mass densities, elemental compositions, effective atomic numbers, and photon interaction coefficients. The phantom, which is composed of numerous small pieces that are similar to LEGO blocks, provides dose and dose distribution measurements in homogeneous and heterogeneous media. The phantom includes dosimeter holders for several types of dosimeters that are frequently used in IMRT dosimetry. An ion chamber and a diode detector were used to test dosimetry in heterogeneous media under radiation fields of various sizes. The data that were measured using these dosimeters were in disagreement when the field sizes were smaller than 1.5 x 1.5 cm 2 for polystyrene and PTFE, or smaller than 3 x 3 cm 2 for an air cavity. The discrepancy was as large as 41% for the air cavity when the field size was 0.7 x 0.7 cm 2 , highlighting one of the challenges of IMRT small field dosimetry. The LEGO-type phantom is also very useful for two-dimensional dosimetry analysis, which elucidates the electronic dis-equilibrium phenomena on or near the heterogeneity boundaries

  6. Development and evaluation of a phantom for multi-purpose dosimetry in intensity-modulated radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hae Sun; Kim, Chan Hyeong [Hanyang University, Seoul (Korea, Republic of); Park, Joo Hwan [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Han, Young Yih [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kum, O Yeon [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    A LEGO-type multi-purpose dosimetry phantom was developed for intensity-modulated radiation therapy (IMRT), which requires various types of challenging dosimetry. Polystyrene, polyethylene, polytetrafluoroethylene (PTFE), and polyurethane foam (PU-F) were selected to represent muscle, fat, bone, and lung tissue, respectively, after considering the relevant mass densities, elemental compositions, effective atomic numbers, and photon interaction coefficients. The phantom, which is composed of numerous small pieces that are similar to LEGO blocks, provides dose and dose distribution measurements in homogeneous and heterogeneous media. The phantom includes dosimeter holders for several types of dosimeters that are frequently used in IMRT dosimetry. An ion chamber and a diode detector were used to test dosimetry in heterogeneous media under radiation fields of various sizes. The data that were measured using these dosimeters were in disagreement when the field sizes were smaller than 1.5 x 1.5 cm{sup 2} for polystyrene and PTFE, or smaller than 3 x 3 cm{sup 2} for an air cavity. The discrepancy was as large as 41% for the air cavity when the field size was 0.7 x 0.7 cm{sup 2}, highlighting one of the challenges of IMRT small field dosimetry. The LEGO-type phantom is also very useful for two-dimensional dosimetry analysis, which elucidates the electronic dis-equilibrium phenomena on or near the heterogeneity boundaries

  7. Setting-Up Of A Film Dosimetry System For High Energy Electron Beams And Development Of Computer Programs For Data Processing

    International Nuclear Information System (INIS)

    Schwob, N.; Schwob, W.; Loewenthal, E.

    1999-01-01

    Film dosimetry has the advantage over other dosimetry methods, of having a high spatial resolution and a fast two dimensional data acquisition. We have set up a system using a film digitizer with its associated software, dedicated to radiosurgery and we have developed data processing programs in Visual Basic for Excel. Data acquisition is not limited to water equivalent media: correction factors can be provided in the data processing procedure

  8. ESR Dosimetry

    International Nuclear Information System (INIS)

    Baffa, Oswaldo; Rossi, Bruno; Graeff, Carlos; Kinoshita, Angela; Chen Abrego, Felipe; Santos, Adevailton Bernardo dos

    2004-01-01

    ESR dosimetry is widely used for several applications such as dose assessment in accidents, medical applications and sterilization of food and other materials. In this work the dosimetric properties of natural and synthetic Hydroxyapatite, Alanine, and 2-Methylalanine are presented. Recent results on the use of a K-Band (24 GHz) ESR spectrometer in dosimetry are also presented

  9. Two-dimensional profiling of Xanthomonas campestris pv. viticola ...

    African Journals Online (AJOL)

    However, the analysis of the 2D-PAGE gel images revealed a larger number of spots in the lysis method when compared to the others. Taking ... Keywords: Bacterial canker, Vitis vinifera, proteomics, sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE), two-dimensional gel electrophoresis (2D-PAGE).

  10. Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method

    Directory of Open Access Journals (Sweden)

    HosseiniAliabadi S. J.

    2015-06-01

    Full Text Available Background: The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. Objective: A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry. Method: Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval. Result: The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method. Conclusion: This system can be utilized in large scale environmental monitoring with a higher accuracy

  11. The impact of the oxygen scavenger on the dose-rate dependence and dose sensitivity of MAGIC type polymer gels

    Science.gov (United States)

    Khan, Muzafar; Heilemann, Gerd; Kuess, Peter; Georg, Dietmar; Berg, Andreas

    2018-03-01

    Recent developments in radiation therapy aimed at more precise dose delivery along with higher dose gradients (dose painting) and more efficient dose delivery with higher dose rates e.g. flattening filter free (FFF) irradiation. Magnetic-resonance-imaging based polymer gel dosimetry offers 3D information for precise dose delivery techniques. Many of the proposed polymer gels have been reported to exhibit a dose response, measured as relaxation rate ΔR2(D), which is dose rate dependent. A lack of or a reduced dose-rate sensitivity is very important for dosimetric accuracy, especially with regard to the increasing clinical use of FFF irradiation protocols with LINACs at high dose rates. Some commonly used polymer gels are based on Methacrylic-Acid-Gel-Initiated-by-Copper (MAGIC). Here, we report on the dose sensitivity (ΔR2/ΔD) of MAGIC-type gels with different oxygen scavenger concentration for their specific dependence on the applied dose rate in order to improve the dosimetric performance, especially for high dose rates. A preclinical x-ray machine (‘Yxlon’, E  =  200 kV) was used for irradiation to cover a range of dose rates from low \\dot{D} min  =  0.6 Gy min-1 to high \\dot{D} max  =  18 Gy min-1. The dose response was evaluated using R2-imaging of the gel on a human high-field (7T) MR-scanner. The results indicate that all of the investigated dose rates had an impact on the dose response in polymer gel dosimeters, being strongest in the high dose region and less effective for low dose levels. The absolute dose rate dependence \\frac{(Δ R2/Δ D)}{Δ \\dot{D}} of the dose response in MAGIC-type gel is significantly reduced using higher concentrations of oxygen scavenger at the expense of reduced dose sensitivity. For quantitative dose evaluations the relative dose rate dependence of a polymer gel, normalized to its sensitivity is important. Based on this normalized sensitivity the dose rate sensitivity was reduced distinctly

  12. Dosimetry of ionizing radiation

    International Nuclear Information System (INIS)

    Musilek, L.; Seda, J.; Trousil, J.

    1992-01-01

    The publication deals with a major field of ionizing radiation dosimetry, viz., integrating dosimetric methods, which are the basic means of operative dose determination. It is divided into the following sections: physical and chemical effects of ionizing radiation; integrating dosimetric methods for low radiation doses (film dosimetry, nuclear emulsions, thermoluminescence, radiophotoluminescence, solid-state track detectors, integrating ionization dosemeters); dosimetry of high ionizing radiation doses (chemical dosimetric methods, dosemeters based on the coloring effect, activation detectors); additional methods applicable to integrating dosimetry (exoelectron emission, electron spin resonance, lyoluminescence, etc.); and calibration techniques for dosimetric instrumentation. (Z.S.). 422 refs

  13. MRI dosimetry using an echo-quotient technique for high dose rate brachytherapy

    International Nuclear Information System (INIS)

    Ansbacher, W.

    1996-01-01

    MRI gel dosimetry is a relatively new technique that has many advantages over conventional methods, and is particularly suited to High Dose Rate (HDR) Brachytherapy. The dosimeter has high spatial resolution and a water-equivalent response over a wide range of photon energies. Because it is an integrating dosimeter, it allows for efficient mapping of the dynamically-produced distributions from an HDR source. As an example of this technique, the dose response, which is calibrated in terms of the change in spin-spin relaxation time, has been used to investigate the anisotropy of an HDR source. (author). 1 fig

  14. Quasi-one-dimensional nanostructured cobalt (Co) intercalated vanadium oxide (V{sub 2}O{sub 5}): Peroxovanadate sol gel synthesis and structural study

    Energy Technology Data Exchange (ETDEWEB)

    Langie da Silva, Douglas, E-mail: douglas.langie@ufpel.edu.br [Departamento de Física, Universidade Federal de Pelotas, Caixa Postal 354, Pelotas 96010-900 (Brazil); Moreira, Eduardo Ceretta [Laboratório de Espectroscopia, Universidade Federal do Pampa, Campus Bagé, Bagé 96400-970 (Brazil); Dias, Fábio Teixeira; Neves Vieira, Valdemar das [Departamento de Física, Universidade Federal de Pelotas, Caixa Postal 354, Pelotas 96010-900 (Brazil); Brandt, Iuri Stefani; Cas Viegas, Alexandre da; Pasa, André Avelino [Laboratório de Filmes Finos e Superfícies, Universidade Federal de Santa Catarina, Caixa Postal 476, Florianópolis 88.040-900 (Brazil)

    2015-01-15

    Nanostructured cobalt vanadium oxide (V{sub 2}O{sub 5}) xerogels spread onto crystalline Si substrates were synthesized via peroxovanadate sol gel route. The resulting products were characterized by distinct experimental techniques. The surface morphology and the nanostructure of xerogels correlate with Co concentration. The decrease of the structural coherence length is followed by the formation of a loose network of nanopores when the concentration of intercalated species was greater than 4 at% of Co. The efficiency of the synthesis route also drops with the increase of Co concentration. The interaction between the Co(OH{sub 2}){sub 6}{sup 2+} cations and the (H{sub 2}V{sub 10}O{sub 28}){sup 4−} anions during the synthesis was suggested as a possible explanation for the incomplete condensation of the V{sub 2}O{sub 5} gel. Finally the experimental results points for the intercalation of Co between the bilayers of the V{sub 2}O{sub 5}. In this scenario two possible preferential occupation sites for the metallic atoms in the framework of the xerogel were proposed. - Graphical abstract: Quasi-one-dimensional nanostructured cobalt (Co) intercalated vanadium oxide (V{sub 2}O{sub 5}) nanoribbons synthesized by peroxovanadate sol gel route. - Highlights: • Nanostructured cobalt V{sub 2}O{sub 5} gel spread onto c{sub S}i were synthesized via peroxovanadate sol gel route. • The micro and nanostructure correlates with the cobalt content. • The efficiency of the synthesis route shows to be also dependent of Co content. • The experimental results points for the intercalation of Co between the bilayers of the V{sub 2}O{sub 5} xerogel.

  15. Two Dimensional Electrophoresis of Galactosidase Relating to the Disappearance of Bombyx Lectin Activity

    OpenAIRE

    カトウ, ヤスオ; Yasuo, Kato

    2004-01-01

    "Two dimensional polyacrylamide gel electroporesis (2 D-PAGE) analysis on the haemolymph of Bombyx mori was performed using the Mini-PROTEAN mini tube gel two dimensional polyacrylamide gel electrophoresis system (Bio-Rad Laboratories, Inc.). The result on various electrophoretical conditions using the haemolymph-protein showed the possibility that the haemolymph-protein was separated actually by means of this method. Moreover, the result of 2 D-PAGE analysis on Fraction II obtained by gel fi...

  16. Three dimensional intensity modulated brachytherapy (IMBT): Dosimetry algorithm and inverse treatment planning

    International Nuclear Information System (INIS)

    Shi Chengyu; Guo Bingqi; Cheng, Chih-Yao; Esquivel, Carlos; Eng, Tony; Papanikolaou, Niko

    2010-01-01

    Purpose: The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is to introduce the concept of three dimensional (3D) intensity modulated brachytherapy and solve two fundamental issues regarding the application of 3D IMBT treatment planning: The dose calculation algorithm and the inverse treatment planning method. Methods: A 3D IMBT treatment planning system prototype was developed using the MATLAB platform. This system consists of three major components: (1) A comprehensive IMBT source calibration method with dosimetric inputs from Monte Carlo (EGSnrc) simulations; (2) a ''modified TG-43'' (mTG-43) dose calculation formalism for IMBT dosimetry; and (3) a physical constraint based inverse IMBT treatment planning platform utilizing a simulated annealing optimization algorithm. The model S700 Axxent electronic brachytherapy source developed by Xoft, Inc. (Fremont, CA), was simulated in this application. Ten intracavitary accelerated partial breast irradiation (APBI) cases were studied. For each case, an ''isotropic plan'' with only optimized source dwell time and a fully optimized IMBT plan were generated and compared to the original plan in various dosimetric aspects, such as the plan quality, planning, and delivery time. The issue of the mechanical complexity of the IMBT applicator is not addressed in this study. Results: IMBT approaches showed superior plan quality compared to the original plans and the isotropic plans to different extents in all studied cases. An extremely difficult case with a small breast and a small distance to the ribs and skin, the IMBT plan minimized the high dose volume V 200 by 16.1% and 4.8%, respectively, compared to the original and the isotropic plans. The conformity index for the

  17. Three dimensional intensity modulated brachytherapy (IMBT): Dosimetry algorithm and inverse treatment planning

    Energy Technology Data Exchange (ETDEWEB)

    Shi Chengyu; Guo Bingqi; Cheng, Chih-Yao; Esquivel, Carlos; Eng, Tony; Papanikolaou, Niko [Cancer Therapy and Research Center, University of Texas Health Science Center at San Antonio, San Antonio, Texas 78229 (United States); Department of Radiation Oncology, Oklahoma University Health Science Center, Oklahoma City, Oklahoma 73104 (United States); Cancer Therapy and Research Center, University of Texas Health Science Center at San Antonio, San Antonio, Texas 78229 (United States)

    2010-07-15

    Purpose: The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is to introduce the concept of three dimensional (3D) intensity modulated brachytherapy and solve two fundamental issues regarding the application of 3D IMBT treatment planning: The dose calculation algorithm and the inverse treatment planning method. Methods: A 3D IMBT treatment planning system prototype was developed using the MATLAB platform. This system consists of three major components: (1) A comprehensive IMBT source calibration method with dosimetric inputs from Monte Carlo (EGSnrc) simulations; (2) a ''modified TG-43'' (mTG-43) dose calculation formalism for IMBT dosimetry; and (3) a physical constraint based inverse IMBT treatment planning platform utilizing a simulated annealing optimization algorithm. The model S700 Axxent electronic brachytherapy source developed by Xoft, Inc. (Fremont, CA), was simulated in this application. Ten intracavitary accelerated partial breast irradiation (APBI) cases were studied. For each case, an ''isotropic plan'' with only optimized source dwell time and a fully optimized IMBT plan were generated and compared to the original plan in various dosimetric aspects, such as the plan quality, planning, and delivery time. The issue of the mechanical complexity of the IMBT applicator is not addressed in this study. Results: IMBT approaches showed superior plan quality compared to the original plans and the isotropic plans to different extents in all studied cases. An extremely difficult case with a small breast and a small distance to the ribs and skin, the IMBT plan minimized the high dose volume V{sub 200} by 16.1% and 4.8%, respectively, compared to the original and the

  18. Three dimensional intensity modulated brachytherapy (IMBT): dosimetry algorithm and inverse treatment planning.

    Science.gov (United States)

    Shi, Chengyu; Guo, Bingqi; Cheng, Chih-Yao; Esquivel, Carlos; Eng, Tony; Papanikolaou, Niko

    2010-07-01

    The feasibility of intensity modulated brachytherapy (IMBT) to improve dose conformity for irregularly shaped targets has been previously investigated by researchers by means of using partially shielded sources. However, partial shielding does not fully explore the potential of IMBT. The goal of this study is to introduce the concept of three dimensional (3D) intensity modulated brachytherapy and solve two fundamental issues regarding the application of 3D IMBT treatment planning: The dose calculation algorithm and the inverse treatment planning method. A 3D IMBT treatment planning system prototype was developed using the MATLAB platform. This system consists of three major components: (1) A comprehensive IMBT source calibration method with dosimetric inputs from Monte Carlo (EGSnrc) simulations; (2) a "modified TG-43" (mTG-43) dose calculation formalism for IMBT dosimetry; and (3) a physical constraint based inverse IMBT treatment planning platform utilizing a simulated annealing optimization algorithm. The model S700 Axxent electronic brachytherapy source developed by Xoft, Inc. (Fremont, CA), was simulated in this application. Ten intracavitary accelerated partial breast irradiation (APBI) cases were studied. For each case, an "isotropic plan" with only optimized source dwell time and a fully optimized IMBT plan were generated and compared to the original plan in various dosimetric aspects, such as the plan quality, planning, and delivery time. The issue of the mechanical complexity of the IMBT applicator is not addressed in this study. IMBT approaches showed superior plan quality compared to the original plans and tht isotropic plans to different extents in all studied cases. An extremely difficult case with a small breast and a small distance to the ribs and skin, the IMBT plan minimized the high dose volume V200 by 16.1% and 4.8%, respectively, compared to the original and the isotropic plans. The conformity index for the target was increased by 0.13 and 0

  19. Studies on the proteinaceous gel secretion from the skin of the ...

    African Journals Online (AJOL)

    PRECIOUS

    2009-12-15

    Dec 15, 2009 ... and SDS-PAGE analysis of the proteinaceous gel of catfish, A. ... SDS–PAGE. One dimensional sodium dodecyl sulphate (SDS) poly acrylamide gel electrophoresis (PAGE) was carried out to estimate the mole- cular weight of the ... 0.2% Triton X-100, was defined as percent hemolysis (Park et al.,. 1997).

  20. Clinical dosimetry

    International Nuclear Information System (INIS)

    Rassow, J.

    1973-01-01

    The main point of this paper on clinical dosimetry which is to be understood here as application of physical dosimetry on accelerators in medical practice, is based on dosimetric methodics. Following an explanation of the dose parameters and description of the dose distribution important for clinical practice as well as geometric irradiation parameters, the significance of a series of physical parameters such as accelerator energy, surface energy of average stopping power etc. is dealt with in detail. Following a section on field homogenization with bremsstrahlung and electron radiation, details on dosimetry in clinical practice are given. Finally, a few problems of dosemeter or monitor calibration on accelerators are described. The explanations are supplemented by a series of diagrams and tables. (ORU/LH) [de

  1. Optimized Protocol for Protein Extraction from the Breast Tissue that is Compatible with Two-Dimensional Gel Electrophoresis

    Directory of Open Access Journals (Sweden)

    Olena Zakharchenko

    2011-01-01

    Full Text Available Proteomics is a highly informative approach to analyze cancer-associated transformation in tissues. The main challenge to use a tissue for proteomics studies is the small sample size and difficulties to extract and preserve proteins. The choice of a buffer compatible with proteomics applications is also a challenge. Here we describe a protocol optimized for the most efficient extraction of proteins from the human breast tissue in a buffer compatible with two-dimensional gel electrophoresis (2D-GE. This protocol is based on mechanically assisted disintegration of tissues directly in the 2D-GE buffer. Our method is simple, robust and easy to apply in clinical practice. We demonstrate high quality of separation of proteins prepared according to the reported here protocol.

  2. Fast neutron spectrometry and dosimetry; Spectrometrie et dosimetrie des neutrons rapides

    Energy Technology Data Exchange (ETDEWEB)

    Blaize, S; Ailloud, J; Mariani, J; Millot, J P [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    We have studied fast neutron spectrometry and dosimetry through the recoil protons they produce in hydrogenated samples. In spectrometric, we used nuclear emulsions, in dosimetric, we used polyethylene coated with zinc sulphide and placed before a photomultiplier. (author)Fren. [French] Nous avons etudie la spectrometrie et la dosimetrie des neutrons rapides en utilisant les protons de recul qu'ils produisent dans une matiere hydrogenee. En spectrometrie, nous avons employe des emulsions nucleaires, en dosimetrie, du polyethylene recouvert de sulfure de zinc place devant un photomultiplicateur. (auteur)

  3. Dosimetry Control: Technic and methods. Proceedings of the international workshop 'Actual problems of dosimetry'

    International Nuclear Information System (INIS)

    Lyutsko, A.M.; Nesterenko, V.B.; Chudakov, V.A.; Konoplya, E.F.; Milyutin, A.A.

    1997-10-01

    There is a number of unsolved problems of both dosimetric and radiometric control, questions of the biological dosimetry, reconstruction of dozes of irradiation of the population at radiation incidents, which require coordination of efforts of scientists in various areas of a science. The submitted materials are grouped on five units: dosimetry engineering, biological dosimetry and markers of radiation impact, dosimetry of a medical irradiation, normative and measurement assurance of the dosimetric control, monitoring and reconstruction of dozes at radiation incidents

  4. Non-conventional personal dosimetry techniques

    International Nuclear Information System (INIS)

    Regulla, D.F.

    1984-01-01

    Established dosimetry has achieved a high standard in personnel monitoring. This applies particularly to photon dosimetry. Nevertheless, even in photon dosimetry, improvements and changes are being made. The reason may be technological progress, or the introduction of new tasks on the basis of the recommendations of international bodies (e.g. the new ICRU measurement unit) of national legislation. Since we are restricting ourselves here to technical trends the author would like to draw attention to various activities of current interest, e.g. the computation of receptor-related conversion coefficients from personal dose to organ or body doses, taking into account the conditions of exposure with respect to differential energy and angular distribution of the radiation field. Realistic data on exposure geometry are taken from work place analyses. Furthermore, the data banks of central personal dosimetry services are subject to statistical evaluation and radiation protection trend analysis. Technological progress and developments are considered from the point of view of personal dosimetry, partial body or extremity dosimetry and accidental dosimetry

  5. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1999-01-01

    The Dosimetry and Calibration Section fulfils two tasks within CERN's Radiation Protection Group: the Individual Dosimetry Service monitors more than 5000 persons potentially exposed to ionizing radiation on the CERN sites, and the Calibration Laboratory verifies throughout the year, at regular intervals, over 1000 instruments, monitors, and electronic dosimeters used by RP Group. The establishment of a Quality Assurance System for the Individual Dosimetry Service, a requirement of the new Swiss Ordinance for personal dosimetry, put a considerable workload on the section. Together with an external consultant it was decided to identify and then describe the different 'processes' of the routine work performed in the dosimetry service. The resulting Quality Manual was submitted to the Federal Office for Public Health in Bern in autumn. The CERN Individual Dosimetry Service will eventually be officially endorsed after a successful technical test in March 1999. On the technical side, the introduction of an automatic development machine for gamma films was very successful. It processes the dosimetric films without an operator being present, and its built-in regeneration mechanism keeps the concentration of the processing chemicals at a constant level

  6. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Boyd, A.W.; Chadwick, K.H.; McDonald, J.C.; Miller, A.

    1989-01-01

    Radiation processing is a relatively young industry with broad applications and considerable commercial success. Dosimetry provides an independent and effective way of developing and controlling many industrial processes. In the sterilization of medical devices and in food irradiation, where the radiation treatment impacts directly on public health, the measurements of dose provide the official means of regulating and approving its use. In this respect, dosimetry provides the operator with a means of characterizing the facility, of proving that products are treated within acceptable dose limits and of controlling the routine operation. This book presents an up-to-date review of the theory, data and measurement techniques for radiation processing dosimetry in a practical and useful way. It is hoped that this book will lead to improved measurement procedures, more accurate and precise dosimetry and a greater appreciation of the necessity of dosimetry for radiation processing. (author)

  7. Thin film tritium dosimetry

    Science.gov (United States)

    Moran, Paul R.

    1976-01-01

    The present invention provides a method for tritium dosimetry. A dosimeter comprising a thin film of a material having relatively sensitive RITAC-RITAP dosimetry properties is exposed to radiation from tritium, and after the dosimeter has been removed from the source of the radiation, the low energy electron dose deposited in the thin film is determined by radiation-induced, thermally-activated polarization dosimetry techniques.

  8. Study of the influence of gold particles on the absorbed dose in soft tissue using polymer gel dosimetry

    International Nuclear Information System (INIS)

    Afonso, Luciana Caminha

    2011-01-01

    The presence of high-Z material adjacent to soft tissue, when submitted to irradiation, enhances locally the absorbed dose in these soft tissues. Such effect occurs due to the outscattering of photoelectrons from the high-Z material. Polymer gel dosimeters have been used to investigate this effect. Analytic calculations to estimate the dose enhancement and Monte Carlo simulations have been performed. Samples containing polymer gel (PG) with 0.005 gAu/gPG and pure polymer gel have been irradiated using an X-rays beam produced by 150 kV, filtered with 4 mm Al and 5 mm Cu, which resulted in an approximately 20% higher absorbed dose in the samples with gold in comparison to those with pure polymer gel. The analytic calculations and the Monte Carlo simulation resulted in a dose enhancement factor of approximately 30%. (author)

  9. Basic investigations on the performance of a normoxic polymer gel with tetrakis-hydroxy-methyl-phosphonium chloride as an oxygen scavenger: Reproducibility, accuracy, stability, and dose rate dependence

    International Nuclear Information System (INIS)

    Bayreder, Christian; Georg, Dietmar; Moser, Ewald; Berg, Andreas

    2006-01-01

    Magnetic resonance (MR)-based polymer gel dosimetry using normoxic polymer gels, represents a new dosimetric method specially suited for high-resolution three-dimensional dosimetric problems. The aim of this study was to investigate the dose response with regard to stability, accuracy, reproducibility, and the dose rate dependence. Tetrakis-hydroxy-methyl-phosphonium chloride (THPC) is used as an oxygen scavenger, and methacrylic acid as a monomer. Accuracy, reproducibility, and dose resolution were determined for MR protocols at low spatial resolution (typical for clinical scanners), medium, and microimaging-resolution protocols at three different dose levels. The dose-response stability and preirradiation-induced variations in R2, related to the time interval between preparation and irradiation of the polymer gel, were investigated. Also postirradiation stability of the polymer gel was considered. These experiments were performed using a 60 Co beam (E=1.2 MV) in a water phantom. Moreover, we investigated the dose rate dependence in the low, medium, and saturation dose region of the normoxic polymer gel using a linear accelerator at photon energy of 25 MV. MR scanning was performed on a 3 T whole body scanner (MEDSPEC 30/80, BRUKER BIOSPIN, Ettlingen, Germany) using several coils and different gradient systems adapted to the acquired spatial resolution investigated. For T2-parameter selective imaging and determination of the relaxation rate R2=1/T2, a multiple spin echo sequence with 20 equidistant echoes was used. With regard to preirradiation induced variations R2 increases significantly with the increasing time interval between the polymer gel preparation and irradiation. Only a slight increase in R2 can be observed for varying the postirradiation-time solely. The dose reproducibility at voxel volumes of about 1.4x1.4x2 mm 3 is better than 2%. The accuracy strongly depends on the calibration curve. THPC represents a very effective oxygen scavenger in

  10. Development of a new mapping technique for 3D gel dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Alwan, R.; Guermeur, F.; Svoboda, J.; Simonin, L.; Bailly, Y.; Akovicka, L. [Centre de Recherche sur les Ecoulements, Surfaces et Transferts (FEMTO-ST/CREST UMR CNRS 6174), 25 - Belfort-Montbeliard (France); David, C. [Belfort/Montbeliard Hospital, Dept. of Radiotherapy, 25 (France); Svoboda, J. [Czech Technical Univ., Dept. of Dosimetry (Czech Republic)

    2006-07-01

    The dosimetric gel developed at the laboratory seems to be interesting: its principle does not require to perform measurement immediately after irradiation. In addition, it has been demonstrated that its optical response versus the dose is linear over the range 4 - 10 Gy. as shown the 633 nm wavelength has the lowest sensitivity among the others wavelengths. Consequently, it is not well adapted to detect the small decreases of density of scattering micro-particles so the the authors intend to test other wavelengths in further equipments. It is also interesting to note that the uncertainty on the calibration of ionisation chamber is 5%. (N.C.)

  11. Supercapacitors based on two dimensional VO2 nanosheet electrodes in organic gel electrolyte

    KAUST Repository

    Rakhi, R.B.

    2016-10-16

    VO2 is a low band-gap semiconductor with relatively high conductivity among transition metal oxides, which makes it an interesting material for supercapacitor electrode applications. The performance of VO2 as supercapacitor electrode in organic electrolytes has never been reported before. Herein, two-dimensional nanosheets of VO2 are prepared by the simultaneous solution reduction and exfoliation from bulk V2O5 powder by hydrothermal method. A specific capacitance of 405 Fg−1 is achieved for VO2 based supercapacitor in an organic electrolyte, in three electrode configuration. The symmetric capacitor based on VO2 nanosheet electrodes and the liquid organic electrolyte exhibits an energy density of 46 Wh kg−1 at a power density of 1.4 kW kg−1 at a constant current density of 1 Ag−1. Furthermore, flexible solid-state supercapacitors are fabricated using same electrode material and Alumina-silica based gel electrolyte. The solid-state device delivers a specific capacitance of 145 Fg−1 and a device capacitance of 36 Fg−1 at a discharge current density of 1 Ag−1. Series combination of three solid state capacitors is capable of lighting up a red LED for more than 1 minute.

  12. Fundamentals of x-ray dosimetry

    International Nuclear Information System (INIS)

    Roesch, W.C.

    1976-01-01

    Fundamental information about x-ray dosimetry is presented. Definitions are given and expanded on for dose, absorbed dose including microdosimetry, radiation physics (properties of the radiation that are important to dosimetry), and dosimetry (how the properties are dealt with in determining dose). 5 figs, 12 refs

  13. Dose verification in HDR brachytherapy and IMRT with Fricke gel-layer dosimeters

    International Nuclear Information System (INIS)

    Gambarini, G.; Negri, A.; Bartesaghi, G.; Pirola, L.; Carrara, M.; Gambini, I.; Tomatis, S.; Fallai, C.; Zonca, G.; Stokucova, J.

    2009-10-01

    At the Department of Physics of the Universita degli Studi di Milano in collaboration with the Medical Physics Unit and the Radiotherapy Unit of the Fondazione IRCCS Istituto Nazionale dei Tumori di Milano the research of a dosimetric technique based on Fricke gel layers and optical analysis in under study. In fact, Fricke gel layer dosimeters (FGLD) have various advantages such as the tissue-equivalence for photons in the clinical energy interval, the possibility to obtain the spatial information about continuous dose distribution and not only a point dose distribution as it is for example in the case of ionization chambers, TLD or diodes and the possibility to obtain the information about 3D dose distributions. In this work, specific applications of FGLD to absolute dosimetry in radiotherapy have been studied, i.e. in-phantom measurements of complex intensity modulated radiation therapy fields (IMRT) and complex brachytherapy fields. (Author)

  14. Efficient method of protein extraction from Theobroma cacao L. roots for two-dimensional gel electrophoresis and mass spectrometry analyses.

    Science.gov (United States)

    Bertolde, F Z; Almeida, A-A F; Silva, F A C; Oliveira, T M; Pirovani, C P

    2014-07-04

    Theobroma cacao is a woody and recalcitrant plant with a very high level of interfering compounds. Standard protocols for protein extraction were proposed for various types of samples, but the presence of interfering compounds in many samples prevented the isolation of proteins suitable for two-dimensional gel electrophoresis (2-DE). An efficient method to extract root proteins for 2-DE was established to overcome these problems. The main features of this protocol are: i) precipitation with trichloroacetic acid/acetone overnight to prepare the acetone dry powder (ADP), ii) several additional steps of sonication in the ADP preparation and extractions with dense sodium dodecyl sulfate and phenol, and iii) adding two stages of phenol extractions. Proteins were extracted from roots using this new protocol (Method B) and a protocol described in the literature for T. cacao leaves and meristems (Method A). Using these methods, we obtained a protein yield of about 0.7 and 2.5 mg per 1.0 g lyophilized root, and a total of 60 and 400 spots could be separated, respectively. Through Method B, it was possible to isolate high-quality protein and a high yield of roots from T. cacao for high-quality 2-DE gels. To demonstrate the quality of the extracted proteins from roots of T. cacao using Method B, several protein spots were cut from the 2-DE gels, analyzed by tandem mass spectrometry, and identified. Method B was further tested on Citrus roots, with a protein yield of about 2.7 mg per 1.0 g lyophilized root and 800 detected spots.

  15. Thermoluminescent dosimetry in veterinary diagnostic radiology

    International Nuclear Information System (INIS)

    Hernández-Ruiz, L.; Jimenez-Flores, Y.; Rivera-Montalvo, T.; Arias-Cisneros, L.; Méndez-Aguilar, R.E.; Uribe-Izquierdo, P.

    2012-01-01

    This paper presents the results of Environmental and Personnel Dosimetry made in a radiology area of a veterinary hospital. Dosimetry was realized using thermoluminescent (TL) materials. Environmental Dosimetry results show that areas closer to the X-ray equipment are safe. Personnel Dosimetry shows important measurements of daily workday in some persons near to the limit established by ICRP. TL results of radiation measurement suggest TLDs are good candidates as a dosimeter to radiation dosimetry in veterinary radiology. - Highlights: ► Personnel dosimetry in laboratory veterinary diagnostic was determined. ► Student workplaces are safe against radiation. ► Efficiency value of apron lead was determined. ► X-ray beams distribution into veterinarian laboratory was measured.

  16. Sixth symposium on neutron dosimetry

    International Nuclear Information System (INIS)

    1987-01-01

    This booklet contains all abstracts of papers presented in 13 sessions. Main topics: Cross sections and Kerma factors; analytical radiobiology; detectors for personnel monitoring; secondary charged particles and microdosimetric basis of q-value for neutrons; personnel dosimetry; concepts for radiation protection; ambient monitoring; TEPC and ion chambers in radiation protection; beam dosimetry; track detectors (CR-39); dosimetry at biomedical irradiation facilities; health physics at therapy facilities; calibration for radiation protection; devices for beam dosimetry (TLD and miscellaneous); therapy and biomedical irradiation facilities; treatment planning. (HP)

  17. Environmental dosimetry

    International Nuclear Information System (INIS)

    Gold, R.

    1977-01-01

    For more than 60 years, natural radiation has offered broad opportunities for basic research as evidenced by many fundamental discoveries. Within the last decade, however, dramatic changes have occurred in the motivation and direction of this research. The urgent need for economical energy sources entailing acceptably low levels of environmental impact has compelled the applied aspects of our radiation environment to become overriding considerations. It is within this general framework that state-of-the-art environmental dosimetry techniques are reviewed. Although applied motivation and relevance underscores the current milieu for both reactor and environmental dosimetry, a perhaps even more unifying force is the broad similarity of reactor and environmental radiation fields. In this review, a comparison of these two mixed radiation fields is presented stressing the underlying similarities that exist. On this basis, the evolution of a strong inner bond between dosimetry methods for both reactor and environmental radiation fields is described. The existence of this bond will be illustrated using representative examples of observed spectra. Dosimetry methods of particularly high applicability for both of these fields are described. Special emphasis is placed on techniques of high sensitivity and absolute accuracy which are capable of resolving the components of these mixed radiation fields

  18. LINKAGE ANALYSIS BY 2-DIMENSIONAL DNA TYPING

    NARCIS (Netherlands)

    MEERMAN, GJT; MULLAART, E; VANDERMEULEN, MA; DENDAAS, JHG; MOROLLI, B; UITTERLINDEN, AG; VIJG, J

    1993-01-01

    In two-dimensional (2-D) DNA typing, genomic DNA fragments are separated, first according to size by electrophoresis in a neutral polyacrylamide gel and second according to sequence by denaturing gradient gel electrophoresis, followed by hybridization analysis using micro- and minisatellite core

  19. Linkage analysis by two-dimensional DNA typing

    NARCIS (Netherlands)

    te Meerman, G J; Mullaart, E; Meulen ,van der Martin; den Daas, J H; Morolli, B; Uitterlinden, A G; Vijg, J

    1993-01-01

    In two-dimensional (2-D) DNA typing, genomic DNA fragments are separated, first according to size by electrophoresis in a neutral polyacrylamide gel and second according to sequence by denaturing gradient gel electrophoresis, followed by hybridization analysis using micro- and minisatellite core

  20. Nuclear accident dosimetry

    International Nuclear Information System (INIS)

    1982-01-01

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  1. Nuclear accident dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-12-31

    The film presents statistical data on criticality accidents. It outlines past IAEA activities on criticality accident dosimetry and the technical documents that resulted from this work. The film furthermore illustrates an international comparison study on nuclear accident dosimetry conducted at the Atomic Energy Research Establishment, Harwell, United Kingdom

  2. Microfluidic device having an immobilized pH gradient and PAGE gels for protein separation and analysis

    Science.gov (United States)

    Sommer, Gregory J.; Hatch, Anson V.; Singh, Anup K.; Wang, Ying-Chih

    2012-12-11

    Disclosed is a novel microfluidic device enabling on-chip implementation of a two-dimensional separation methodology. Previously disclosed microscale immobilized pH gradients (IPG) are combined with perpendicular polyacrylamide gel electrophoresis (PAGE) microchannels to achieve orthogonal separations of biological samples. Device modifications enable inclusion of sodium dodecyl sulfate (SDS) in the second dimension. The device can be fabricated to use either continuous IPG gels, or the microscale isoelectric fractionation membranes we have also previously disclosed, for the first dimension. The invention represents the first all-gel two-dimensional separation microdevice, with significantly higher resolution power over existing devices.

  3. Performance testing of dosimetry processors, status of NRC rulemaking for improved personnel dosimetry processing, and some beta dosimetry and instrumentation problems observed by NRC regional inspectors

    International Nuclear Information System (INIS)

    Dennis, N.A.; Kinneman, J.D.; Costello, F.M.; White, J.R.; Nimitz, R.L.

    1983-01-01

    Early dosimetry processor performance studies conducted between 1967 and 1979 by several different investigators indicated that a significant percentage of personnel dosimetry processors may not be performing with a reasonable degree of accuracy. Results of voluntary performance testing of US personnel dosimetry processors against the final Health Physics Society Standard, Criteria for Testing Personnel Dosimetry Performance by the University of Michigan for the Nuclear Regulatory Commission (NRC) will be summarized with emphasis on processor performance in radiation categories involving beta particles and beta particles and photon mixtures. The current status of the NRC's regulatory program for improved personnel dosimetry processing will be reviewed. The NRC is proposing amendments to its regulations, 10 CFR Part 20, that would require its licensees to utilize specified personnel dosimetry services from processors accredited by the National Voluntary Laboratory Accreditation Program of the National Bureau of Standards. Details of the development and schedule for implementation of the program will be highlighted. Finally, selected beta dosimetry and beta instrumentation problems observed by NRC Regional Staff during inspections of NRC licensed facilities will be discussed

  4. Quantitative imaging for clinical dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Bardies, Manuel [INSERM U601, 9 Quai Moncousu, 44093 Nantes (France)]. E-mail: manu@nantes.inserm.fr; Flux, Glenn [Department of Physics, Royal Marsden NHS Trust, Sutton (United Kingdom); Lassmann, Michael [Department of Nuclear Medicine, Julis-Maximilians University, Wuerzburg (Germany); Monsieurs, Myriam [Department of Health Physics, University of Ghent, 9000 Ghent (Belgium); Savolainen, Sauli [Department of Physical Sciences, University of Helsinki and HUS, Helsinki Medical Imaging Center, Helsinki University Central Hospital (Finland); Strand, Sven-Erik [Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University (Sweden)

    2006-12-20

    Patient-specific dosimetry in nuclear medicine is now a legal requirement in many countries throughout the EU for targeted radionuclide therapy (TRT) applications. In order to achieve that goal, an increased level of accuracy in dosimetry procedures is needed. Current research in nuclear medicine dosimetry should not only aim at developing new methods to assess the delivered radiation absorbed dose at the patient level, but also to ensure that the proposed methods can be put into practice in a sufficient number of institutions. A unified dosimetry methodology is required for making clinical outcome comparisons possible.

  5. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    International Nuclear Information System (INIS)

    Kumada, Hiroaki; Torii, Yoshiya

    2002-09-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal for the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System to set the patient in an actual irradiation position swiftly and accurately. This report describes basic design and procedure of dosimetry, operation manual, data and library structure for JCDS (ver.1.0). (author)

  6. How do monomeric components of a polymer gel dosimeter respond to ionising radiation: A steady-state radiolysis towards preparation of a 3D polymer gel dosimeter

    International Nuclear Information System (INIS)

    Kozicki, Marek

    2011-01-01

    Ionising radiation-induced reactions of aqueous single monomer solutions and mixtures of poly(ethylene glycol) diacrylate (PEGDA) and N,N'-methylenebisacrylamide (Bis) in a steady-state condition are presented below and above gelation doses in order to highlight reactions in irradiated 3D polymer gel dosimeters, which are assigned for radiotherapy dosimetry. Both monomers are shown to undergo radical polymerisation and cross-linking, which result in the measured increase in molecular weight and radius of gyration of the formed polydisperse polymer coils. The formation of nanogels was also observed for Bis solutions at a low concentration. In the case of PEGDA-Bis mixtures, co-polymerisation is suggested as well. At a sufficiently high radiation dose, the formation of a polymer network was observed for both monomers and their mixture. For this reason a sol-gel analysis for PEGDA and Bis was performed gravimetrically and a proposition of an alternative to this method employing a nuclear magnetic resonance technique is made. The two monomers were used for preparation of 3D polymer gel dosimeters having the acronyms PABIG and PABIG nx . The latter is presented for the first time in this work and is a type of the formerly established PABIG polymer gel dosimeter. The elementary characteristics of the new composition are presented, underlining the ease of its preparation, low dose threshold, and slightly increased sensitivity but lower quasi-linear range of dose response in comparison to PABIG. - Highlights: → Steady-state radiolysis of Bis, PEGDA and Bis-PEGDA is examined. → High Mw products are formed at low absorbed doses. → Formation of Bis nanogels is likely; PEGDA solutions form hydrogels. → NMR technique can be used for sol-gel analysis. → Features of 3D polymer gel dosimeters made from PEGDA and Bis are shown.

  7. The use of time-resolved fluorescence in gel-based proteomics for improved biomarker discovery

    Science.gov (United States)

    Sandberg, AnnSofi; Buschmann, Volker; Kapusta, Peter; Erdmann, Rainer; Wheelock, Åsa M.

    2010-02-01

    This paper describes a new platform for quantitative intact proteomics, entitled Cumulative Time-resolved Emission 2-Dimensional Gel Electrophoresis (CuTEDGE). The CuTEDGE technology utilizes differences in fluorescent lifetimes to subtract the confounding background fluorescence during in-gel detection and quantification of proteins, resulting in a drastic improvement in both sensitivity and dynamic range compared to existing technology. The platform is primarily designed for image acquisition in 2-dimensional gel electrophoresis (2-DE), but is also applicable to 1-dimensional gel electrophoresis (1-DE), and proteins electroblotted to membranes. In a set of proof-of-principle measurements, we have evaluated the performance of the novel technology using the MicroTime 100 instrument (PicoQuant GmbH) in conjunction with the CyDye minimal labeling fluorochromes (GE Healthcare, Uppsala, Sweden) to perform differential gel electrophoresis (DIGE) analyses. The results indicate that the CuTEDGE technology provides an improvement in the dynamic range and sensitivity of detection of 3 orders of magnitude as compared to current state-of-the-art image acquisition instrumentation available for 2-DE (Typhoon 9410, GE Healthcare). Given the potential dynamic range of 7-8 orders of magnitude and sensitivities in the attomol range, the described invention represents a technological leap in detection of low abundance cellular proteins, which is desperately needed in the field of biomarker discovery.

  8. Influence of colloidal silicon dioxide on gel strength, robustness, and adhesive properties of diclofenac gel formulation for topical application.

    Science.gov (United States)

    Lu, Zheng; Fassihi, Reza

    2015-06-01

    The objective of this study is to identify the extent of stiffness, adhesiveness, and thixotropic character of a three-dimensional gel network of a 1% diclofenac sodium topical gel formulation in the presence and absence of colloidal silicon dioxide (CSD) and assess its ease of application and adhesiveness using both objective and subjective analysis. The 1% diclofenac gel was mixed with different amounts of CSD (e.g., 0.5, 1, 2, 3, and 5% w/w) and allowed to equilibrate prior to testing. The texture analyzer in combination with a cone-cap assembly was used to objectively investigate the changes in spreadability and adhesiveness of the gel system before and after addition of CSD. Results indicate that an increase in pliability and adhesiveness at levels ≥2 to ≤5% w/w of CSD dispersed in the gel ensues. For subjective analysis, gels with (2% w/w) CSD and in the absence of CSD were uniformly applied to a 20-cm(2) (5 cm × 4 cm) surface area on the forearms of healthy volunteers and vehicle preferences by the volunteers regarding ease of application, durability on the skin, compliance, and feelings concerning its textural properties were assessed. It appears that changes in the gel formulation with the addition of CSD enhance gel viscosity and bonding to the skin. Results further show that changes in physical and rheological characteristics of gel containing 2% w/w CSD did not significantly change subject preferences for the gel preparations. These findings may help formulators to have additional options to develop more robust and cost-effective formulations.

  9. Internal emitter dosimetry: are patient-specific calculations necessary?

    International Nuclear Information System (INIS)

    Sgouros, G.

    1996-01-01

    Full text: The question of whether patient-specific calculations are needed in internal emitter dosimetry arises when radionuclides are used for therapy. In diagnostic procedures the absorbed dose delivered to normal tissue is far below hazardous levels. In internal emitter therapy, the need for patient-specific dosimetry may arise if a large variability in biodistribution, normal tissue toxicity or efficacy is anticipated. Patient-specificity may be accomplished at the level of pharmacokinetics, anatomy/tumor-geometry or both. At the first level, information regarding the biodistribution of a particular radiolabeled agent is obtained and used to determine the maximum activity that may be administered for treatment. The classical example of this is radioiodine therapy for thyroid cancer. In radioiodine therapy, the therapy dose is preceded by a tracer dose of I-131-iodide which is used to measure patient kinetics by imaging and whole-body counting. Absorbed dose estimates obtained from these data are used to constrain the therapy dose to meet safety criteria established in a previously performed dose-response study. The most ambitious approach to patient-specific dosimetry, requires a three-dimensional set of images representing radionuclide distribution (SPECT or PET) and a corresponding set of registered images representing anatomy (CT or MRI). The spatial distribution of absorbed dose or dose-rate may then be obtained by convolution of a point-kernel with the radioactivity distribution or by Monte Carlo calculation. The spatial absorbed dose or dose-rate distribution may be represented as a set of images, as isodose contours, or as dose-volume histograms. The 3-D Monte Carlo approach is, in principle, the most patient-specific; it accounts for patient anatomy and tumor geometry as well as for the spatial distribution of radioactivity. It is also, however, the most logistically and technically demanding. Patients are required to undergo CT or MRI and at least one

  10. 3D dosimetry study of 188Re liquid balloon for intravascular brachytherapy using BANG polymer gel dosemeters

    International Nuclear Information System (INIS)

    Wuu, S.; Schiff, P.B.; Maryanski, M.; Liu, T.; Borzillary, S.; Weinberger, J.

    2002-01-01

    It has been suggested that the combination of intravascular brachytherapy and coronary stent implantation may result in further reduction of restenosis after percutaneous balloon angioplasty. The use of an angioplasty balloon filled with a P 188 Re liquid beta source for intravascular brachytherapy provides the advantage of accurate source positioning and uniform dose distribution to the coronary vessel wall. The effect of source edge and stent on the dose distribution of the target tissue may be clinically important. In BANG gels, the absorbed radiation produces free-radical chain polymerisation of acrylic monomers that are initially dissolved in the gel. The number of polymer particles is proportional to the absorbed dose. In this study, 3D dose distributions are presented for 188 Re balloons, with and without stents, using a prototype He-Ne laser CT scanner and the proprietary BANG polymer gel dosemeters. (author)

  11. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    CERN Document Server

    Kumada, H

    2002-01-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to ...

  12. Three-dimensional viewing and dosimetric calculations of Au-198 implants of the prostate

    International Nuclear Information System (INIS)

    Avizonis, V.N.; Anderson, K.M.; Jani, S.K.; Hussey, D.H.

    1991-01-01

    Dose gradients for brachytherapy vary considerably in three dimensions, which complicates conventional two-dimensional dosimetry. Recent developments in computer graphics technology have enabled visualization of anatomy and radiation doses in three dimensions. The objective of this paper is to develop a three-dimensional viewing and dosimetry program for brachytherapy and to test this system in phantoms and in patients undergoing Au-198 implants in the prostate. Three-dimensional computer algorithms for the author's Silicon Graphics supercomputing workstation were developed, tested, and modified on the basis of studies in phantoms and patients. Studies were performed on phantoms of known dimensions and gold seeds in known locations to assess the accuracy of volume reconstruction, seed placement, and isodose distribution. Isodose curves generated with the three-dimensional system were compared with those generated by a Theratronics Treatment Planning Computer using conventional methods. Twenty patients with permanent Au-198 interstitial implants in the prostate were similarly studied

  13. Alanine EPR dosimetry of therapeutic irradiators

    International Nuclear Information System (INIS)

    Bugay, O.; Bartchuk, V.; Kolesnik, S.; Mazin, M.; Gaponenko, H.

    1999-01-01

    The high-dose alanine EPR dosimetry is a very precise method in the dose range 1-100 kGy. The system is used generally as the standard high-dose transfer dosimetry in many laboratories. This is comparatively expensive technique so it is important to use it as a more universal dosimetry system also in the middle and low dose ranges. The problems of the middle-dose alanine dosimetry are discussed and the solution of several problems is proposed. The alanine EPR dosimetry has been applied to the dose measurements of medical irradiators in the Kiev City Oncology Center. (author)

  14. Comparison of Real-Time Intraoperative Ultrasound-Based Dosimetry With Postoperative Computed Tomography-Based Dosimetry for Prostate Brachytherapy

    International Nuclear Information System (INIS)

    Nag, Subir; Shi Peipei; Liu Bingren; Gupta, Nilendu; Bahnson, Robert R.; Wang, Jian Z.

    2008-01-01

    Purpose: To evaluate whether real-time intraoperative ultrasound (US)-based dosimetry can replace conventional postoperative computed tomography (CT)-based dosimetry in prostate brachytherapy. Methods and Materials: Between December 2001 and November 2002, 82 patients underwent 103 Pd prostate brachytherapy. An interplant treatment planning system was used for real-time intraoperative transrectal US-guided treatment planning. The dose distribution was updated according to the estimated seed position to obtain the dose-volume histograms. Postoperative CT-based dosimetry was performed a few hours later using the Theraplan-Plus treatment planning system. The dosimetric parameters obtained from the two imaging modalities were compared. Results: The results of this study revealed correlations between the US- and CT-based dosimetry. However, large variations were found in the implant-quality parameters of the two modalities, including the doses covering 100%, 90%, and 80% of the prostate volume and prostate volumes covered by 100%, 150%, and 200% of the prescription dose. The mean relative difference was 38% and 16% for doses covering 100% and 90% of the prostate volume and 10% and 21% for prostate volumes covered by 100% and 150% of the prescription dose, respectively. The CT-based volume covered by 200% of the prescription dose was about 30% greater than the US-based one. Compared with CT-based dosimetry, US-based dosimetry significantly underestimated the dose to normal organs, especially for the rectum. The average US-based maximal dose and volume covered by 100% of the prescription dose for the rectum was 72 Gy and 0.01 cm 3 , respectively, much lower than the 159 Gy and 0.65 cm 3 obtained using CT-based dosimetry. Conclusion: Although dosimetry using intraoperative US-based planning provides preliminary real-time information, it does not accurately reflect the postoperative CT-based dosimetry. Until studies have determined whether US-based dosimetry or

  15. Reactor Dosimetry State of the Art 2008

    Science.gov (United States)

    Voorbraak, Wim; Debarberis, Luigi; D'Hondt, Pierre; Wagemans, Jan

    2009-08-01

    data, damage correlations. Two-dimensional mapping of the calculated fission power for the full-size fuel plate experiment irradiated in the advanced test reactor / G. S. Chang and M. A. Lillo. The radiation safety information computational center: a resource for reactor dosimetry software and nuclear data / B. L. Kirk. Irradiated xenon isotopic ratio measurement for failed fuel detection and location in fast reactor / C. Ito, T. Iguchi and H. Harano. Characterization of dosimetry of the BMRR horizontal thimble tubes and broad beam facility / J.-P. Hu, R. N. Reciniello and N. E. Holden. 2007 nuclear data review / N. E. Holden. Further dosimetry studies at the Rhode Island nuclear science / R. N. Reciniello ... [et al.]. Characterization of neutron fields in the experimental fast reactor Joyo MK-III core / S. Maeda ... [et al.]. Measuring [symbol]Li(n, t) and [symbol]B(n, [symbol]) cross sections using the NIST alpha-gamma apparatus / M. S. Dewey ... [et al.]. Improvement of neutron/gamma field evaluation for restart of JMTR / Y. Nagao ... [et al.]. Monitoring of the irradiated neutron fluence in the neutron transmutation doping process of HANARO / M.-S. Kim and S.-J. Park.Training reactor VR-l neutron spectrum determination / M. Vins, A. Kolros and K. Katovsky. Differential cross sections for gamma-ray production by 14 MeV neutrons on iron and bismuth / V. M. Bondar ... [et al.]. The measurements of the differential elastic neutron cross-sections of carbon for energies from 2 to 133 ke V / O. Gritzay ... [et al.]. Determination of neutron spectrum by the dosimetry foil method up to 35 Me V / S. P. Simakov ... [et al.]. Extension of the BGL broad group cross section library / D. Kirilova, S. Belousov and Kr. Ilieva. Measurements of neutron capture cross-section for tantalum at the neutron filtered beams / O. Gritzayand V. Libman. Measurements of microscopic data at GELINA in support of dosimetry / S. Kopecky ... [et al.]. Nuclide guide and international chart of

  16. Dosimetry for radiation processing

    International Nuclear Information System (INIS)

    Miller, Arne

    1986-01-01

    During the past few years significant advances have taken place in the different areas of dosimetry for radiation processing, mainly stimulated by the increased interest in radiation for food preservation, plastic processing and sterilization of medical products. Reference services both by international organizations (IAEA) and national laboratories have helped to improve the reliability of dose measurements. In this paper the special features of radiation processing dosimetry are discussed, several commonly used dosimeters are reviewed, and factors leading to traceable and reliable dosimetry are discussed. (author)

  17. Radiochromic film dosimetry

    International Nuclear Information System (INIS)

    Xu Zhiyong

    2002-01-01

    Radiochromic film dosimetry was developed to measure ionization irradiation dose for industry and medicine. At this time, there are no comprehensive guideline on the medical application, calibration method and densitometer system for medicine. The review gives update on Radiochromic film dosimetry used for medicine, including principles, film model and material, characteristics, calibration method, scanning densitometer system and medical application

  18. Optical and energy dependent response of the alanine gel solution produced at IPEN to clinical photons and electrons beams

    International Nuclear Information System (INIS)

    Silva, Cleber F.

    2011-01-01

    The DL-Alanine (C 3 H 7 NO 2 ) is an amino acid tissue equivalent traditionally used as standard dosimetric material in EPR dosimetry. Recently, it has been studied to be applied in gel dosimetry, considering that the addition of Alanine in the Fricke gel solution improves the production of ferric ions radiation induced. The spectrophotometric evaluation technique can be used comparing the two spectrum wavelengths bands: 457 nm band that corresponds to ferrous ions and 588 nm band that corresponds to ferric ions concentration to evaluate the dosimetric properties of this material. The performance of the Alanine gel solution developed at IPEN has been firstly studied using the spectrophotometric technique aiming to apply this material to 3D clinical doses evaluations using MRI technique. In this work, the optical and the energy dependent response of this solution submitted to clinical photons and electrons beams were studied. Different batches of gel solutions were prepared and maintained at low temperature during 12 h to solidification. Before irradiation, the samples were maintained during 1 h at room temperature. The photons and electrons irradiations were carried out using a Varian 2100C Medical Linear Accelerator of the Radiotherapy Department of the Hospital das Clinicas of the University of Sao Paulo with absorbed doses between 1 and 40 Gy; radiation field of 10 x 10 cm 2 ; photon energies of 6 MeV and 15 MeV; and electron with energies between 6 and 15 MeV. The obtained results indicate that signal response dependence for clinical photons and electrons beams, to the same doses, for Alanine gel dosimeter is better than 3.6 % (1σ), and the energy dependence response, to the same doses, is better 3% (1σ) for both beams. These results indicate that the same calibration factor can be used and the optical response is energy independent in the studied dose range and clinical photons and electrons beams energies. (author)

  19. Dosimetric characterization of VIPARnd gel by optical analysis to high-energy photon beam used in external radiotherapy

    International Nuclear Information System (INIS)

    Dias, Juliana R.; Lima, Renata S.; Lopes, Roseany de V. Vieira; Ceschin, Artemis Marti

    2015-01-01

    Polymer gel dosimetry has been proposed as a possibility for measurements of dose distribution in radiotherapy. This work aims to evaluate the dosimetric characteristics of a VIPARnd for 6 MV photon beam used in radiotherapy using optical investigations. The absorbance spectrum of irradiated gel dosimeter was optical evaluated with spectrophotometer techniques and with CMOS camera readout for dose range of 0 to 50 Gy. Data shows that the VIPARnd has a maximum absorbance at 300 to 320 nm depending on the absorbed dose. The CMOS camera readouts were obtained in RGB color, the absorbance measurements suggest a major response of dose for blue matrix verified with data. The dose-response curve for blue component showed interval of linearity from 1 Gy to 20 Gy. (author)

  20. 11. International conference on solid radiation dosimetry

    International Nuclear Information System (INIS)

    Krylova, I.V.

    1996-01-01

    The main problems discussed during the international conference on solid radiation dosimetry which took place in June 1995 in Budapest are briefly considered. These are the basic physical processes, materials applied for dosimetry, special techniques, personnel monitoring, monitoring of environmental effects, large-dose dosimetry, clinic dosimetry, track detector used for dosimetry, dosimetry in archaeology and geology, equipment and technique for dosimetric measurements. The special attention was paid to superlinearity in the TLD-100 (LiF, Mg, Ti) response function when determining doses of gamma radiation, heavy charged particles, low-energy particle fluxes in particular. New theoretical models were considered

  1. Electron beam irradiation after reconstruction with silicone gel implant in breast cancer

    International Nuclear Information System (INIS)

    Krishnan, L.; Krishnan, E.C.

    1986-01-01

    Irradiation for breast cancer in the presence of a silicone gel breast prosthesis is sometimes necessary. There is a concern among radiation and other oncologists as to whether the presence of the prosthetic implant would interfere with delivery of the needed irradiation doses. Electron beams, with their finite penetration and rapid fall-off, offer a mode of adequately treating the recurrence and minimizing the radiation to the underlying normal structures, such as the lung and the heart. The dose distribution using 9-20 MeV electrons in the presence of a breast prosthesis is compared to the dose distribution without the implant in a tissue equivalent water phantom. The results reveal no significant difference in the dose delivered due to the presence of the prosthesis. Clinical verification of the dosimetry in the presence of the prosthesis confirmed that the presence of the silicone gel implant does not compromise treatment by irradiation in the management of breast cancer

  2. A microcomputer controlled thermoluminescence dosimetry system

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Kicken, P.J.H.

    1980-01-01

    Using a microcomputer, an automatic thermoluminescence dosimetry system for personal dosimetry and thermoluminescence detector (TLD) research was developed. Process automation, statistical computation and dose calculation are provided by this microcomputer. Recording of measurement data, as well as dose record keeping for radiological workers is carried out with floppy disk. The microcomputer also provides a human/system interface by means of a video display and a printer. The main features of this dosimetry system are its low cost, high degree of flexibility, high degree of automation and the feasibility for use in routine dosimetry as well as in TLD research. The system is in use for personal dosimetry, environmental dosimetry and for TL-research work. Because of its modular set-up several components of the system are in use for other applications, too. The system seems suited for medium sized health physics groups. (author)

  3. The Make 2D-DB II package: conversion of federated two-dimensional gel electrophoresis databases into a relational format and interconnection of distributed databases.

    Science.gov (United States)

    Mostaguir, Khaled; Hoogland, Christine; Binz, Pierre-Alain; Appel, Ron D

    2003-08-01

    The Make 2D-DB tool has been previously developed to help build federated two-dimensional gel electrophoresis (2-DE) databases on one's own web site. The purpose of our work is to extend the strength of the first package and to build a more efficient environment. Such an environment should be able to fulfill the different needs and requirements arising from both the growing use of 2-DE techniques and the increasing amount of distributed experimental data.

  4. Characterising an aluminium oxide dosimetry system.

    Science.gov (United States)

    Conheady, Clement F; Gagliardi, Frank M; Ackerly, Trevor

    2015-09-01

    In vivo dosimetry is recommended as a defence-in-depth strategy in radiotherapy treatments and is currently employed by clinics around the world. The characteristics of a new optically stimulated luminescence dosimetry system were investigated for the purpose of replacing an aging thermoluminescence dosimetry system for in vivo dosimetry. The stability of the system was not sufficient to satisfy commissioning requirements and therefore it has not been released into clinical service at this time.

  5. High-resolution two-dimensional gel analysis of proteins in wing imaginal discs: A data base of Drosophila

    International Nuclear Information System (INIS)

    Santaren, J.F.; Garcia-Bellido, A.

    1990-01-01

    An improved method of high-resolution two-dimensional gel electrophoresis has been used to study the patterns of protein synthesis in wing imaginal discs of late instar larvae of Drosophila melanogaster. A small number of discs were radiolabeled with a mixture of 14 C-labeled amino acids or with [ 35 S]methionine and the pattern of labeled proteins was analyzed. One thousand and twenty-five polypeptides (787 acidic (IEF) and 238 basic (NEPHGE)) from wing discs of several wild-type strains have so far been separated and cataloged. All these polypeptides have been numbered and presented in a reference map for further studies. When comparing patterns of label we have found small quantitative differences in rate of synthesis between individuals of the same strain, not due to sexual differences, and very few quantitative and qualitative differences between groups of individuals of different strains

  6. Development of a novel endorectal balloon for two-dimensional in-vivo rectal dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Young Kyung; Jeang, Eun Hee; Min, Soon Ki; Cho, Kwan Ho [National Cancer Center, Goyang (Korea, Republic of); Hwang, Ui Jung [National Medical Center, Seoul (Korea, Republic of); Choi, Sang Hyoun [Korea Cancer Center Hospital, Seoul (Korea, Republic of); Kwak, Jung Won [Asan Medical Center, Seoul (Korea, Republic of)

    2016-05-15

    In the present study, a new endorectal balloon equipped with radiochromic film was developed, and its dosimetric property was evaluated. A metal-oxide-semiconductor field-effect transistor (MOSFET) was used in a rectal balloon to measure the rectal dose in 3D-CRT and IMRT. Additionally, a thermoluminescent dosimeter (TLD) was attached directly onto the rectal balloon to measure the rectal dose in IMRT and proton therapy. However, in vivo dosimetry that uses such point dosimeters cannot provide 2D dose distribution in a rectal wall (RW). In order to obtain the 2D dose distribution in the rectal wall, a 2D dosimeter that incorporates radiosensitive film is required. A new endorectal balloon capable of 2D in vivo rectal dosimetry was developed. Unlike conventional ERBs, this 2DD-ERB was equipped with a radiosensitive film on the outside of the balloon to directly measure the 2D dose distribution delivered to the ARW by the treatment beam. The dosimetric properties of the 2DD-ERB were measured, and the results showed that the measured dose distributions agreed well with their respective treatment plans within 4%. The film-equipped endorectal balloon is expected to be used as an in vivo dosimeter for measuring the dose distribution in the rectal wall in the modern radiotherapy techniques, such as IMRT, VMAT, HT, and IMPT.

  7. Two-dimensional exit dosimetry using a liquid-filled electronic portal imaging device and a convolution model

    International Nuclear Information System (INIS)

    Boellaard, Ronald; Herk, Marcel van; Uiterwaal, Hans; Mijnheer, Ben

    1997-01-01

    Background and purpose: To determine the accuracy of two-dimensional exit dose measurements with an electronic portal imaging device, EPID, using a convolution model for a variety of clinically relevant situations. Materials and methods: Exit doses were derived from portal dose images, obtained with a liquid-filled EPID at distances of 50 cm or more behind the patient, by using a convolution model. The resulting on- and off-axis exit dose values were first compared with ionization chamber exit dose measurements for homogeneous and inhomogeneous phantoms in open and wedged 4,8 and 18 MV photon beams. The accuracy of the EPID exit dose measurements was then determined for a number of anthropomorphic phantoms (lung and larynx) irradiated under clinical conditions and for a few patients treated in an 8 MV beam. The latter results were compared with in vivo exit dose measurements using diodes. Results: The exit dose can be determined from portal images with an accuracy of 1.2% (1 SD) compared with ionization chamber measurements for open beams and homogeneous phantoms at all tested beam qualities. In the presence of wedges and for inhomogeneous phantoms the average relative accuracy slightly deteriorated to 1.7% (1 SD). For lung phantoms in a 4 MV beam a similar accuracy was obtained after refinement of our convolution model, which requires knowledge of the patient contour. Differences between diode and EPID exit dose measurements for an anthropomorphic lung phantom in an 8 MV beam were 2.5% at most, with an average agreement within 1% (1 SD). For larynx phantoms in a 4 MV beam exit doses obtained with an ionization chamber and EPID agreed within 1.5% (1 SD). Finally, exit doses in a few patients irradiated in an 8 MV beam could be determined with the EPID with an accuracy of 1.1% (1 SD) relative to exit dose measurements using diodes. Conclusions: Portal images, obtained with our EPID and analyzed with our convolution model, can be used to determine the exit dose

  8. Dosimetry optimization at COGEMA-La Hague

    International Nuclear Information System (INIS)

    Kalimbadjian, J.

    2000-01-01

    At the present time, the la Hague site strives to apply international recommendations together with national regulations concerning radiation protection, and especially the respect of limitation and optimization principles. The application of these principles is based on the implementation of a passive dosimetry and an active dosimetry. The monthly passive dosimetry is monitored by means of a photographic dosimetry film, completed with lithium fluorine thermoluminescent film badges. This personal dosimetry common to X, β, γ and neutron radiations is carried out in close relationship between the Radiation Protection Department, the Occupational Medical Department and the staff running the Plant. The application or ALARA's principle as well as that of radiation protection optimization implies to implement a complementary active dosimetry enabling to gain in real time, the personal dosimetry of each intervening person, either they be COGEMA's workers or external companies'. This active dosimetry provides with following information: This preventive dosimetry is based on the knowledge of doses integration in real time and is fitted with alarm thresholds according to the total amount of doses and dose rates. Thresholds on the dose rate are also set relatively to the radiological environment. This knowledge of doses and dose rates allows a stricter management of the works, while analyzing them according to the nature of the work, to the location and to the skills of the intervening people. This dosimetry allows to analyze and optimize doses integration according to the works nature for the whole intervening staff. The la Hague Site has developed an active personal dosimetry system, common to every intervening person, COGEMA or external companies. The DOSICARD was thus elaborated, shaped as an electronic dosimeter fitted with an alarm and a smart card. The access to controlled areas is conditioned to information given by the DOSICARD concerning medical aptitudes and

  9. The dosimetry of ionizing radiation

    CERN Document Server

    1990-01-01

    A continuation of the treatise The Dosimetry of Ionizing Radiation, Volume III builds upon the foundations of Volumes I and II and the tradition of the preceeding treatise Radiation Dosimetry. Volume III contains three comprehensive chapters on the applications of radiation dosimetry in particular research and medical settings, a chapter on unique and useful detectors, and two chapters on Monte Carlo techniques and their applications.

  10. Secondary standard dosimetry laboratory (SSDL)

    International Nuclear Information System (INIS)

    Md Saion bin Salikin.

    1983-01-01

    A secondary Standard Dosimetry Laboratory has been established in the Tun Ismail Research Centre, Malaysia as a national laboratory for reference and standardization purposes in the field of radiation dosimetry. This article gives brief accounts on the general information, development of the facility, programmes to be carried out as well as other information on the relevant aspects of the secondary standard dosimetry laboratory. (author)

  11. Dosimetry in nuclear power plants

    International Nuclear Information System (INIS)

    Lastra B, J. A.

    2008-12-01

    To control the occupationally exposed personnel dose working at the Laguna Verde nuclear power plant, two types of dosemeters are used, the thermoluminescent (TLD) which is processed monthly, and the direct reading dosemeter that is electronic and works as daily control of personal dose. In the case of the electronic dosemeters of direct reading conventional, the readings and dose automatic registers and the user identity to which he was assigned to each dosemeter was to carry out the restricted area exit. In activities where the ionizing radiation sources are not fully characterized, it is necessary to relocate the personal dosemeter or assigned auxiliary dosemeters (TLDs and electronics) to determine the dose received by the user to both whole body and in any specific area of it. In jobs more complicated are used a tele dosimetry system where the radiation protection technician can be monitoring the user dose to remote control, the data transmission is by radio. The dosimetry activities are documented in procedures that include dosemeter inventories realization, the equipment and dosemeters calibration, the dosimetry quality control and the discrepancies investigation between the direct reading and TLD systems. TLD dosimetry to have technical expertise in direct and indirect dosimetry and two technicians in TLD dosimetry; electronic dosimetry to have 4 calibration technicians. For the electronic dosemeters are based on a calibrator source of Cesium-137. TLD dosemeters to have an automatic radiator, an automatic reader which can read up to 100 TLD dosemeters per hour and a semiautomatic reader. To keep the equipment under a quality process was development a process of initial entry into service and carried out a periodic verification of the heating cycles. It also has a maintenance contract for the equipment directly with the manufacturer to ensure their proper functioning. The vision in perspective of the dosimetry services of Laguna Verde nuclear power plant

  12. Dosimetry for the treatment of cystic craniopharyngioma through radiocolloids with 186 Re

    International Nuclear Information System (INIS)

    Rojas, E.L.; Al-dweri, F.M.O.; Lallena, A.M.; Bodineau, C.; Galan, P.

    2003-01-01

    The cystic craniopharyngioma (CQ) are histologically benign tumors that can affect important organs, as the hypothalamus or the optic nerve. They are treated introducing, inside the cyst, a radioactive colloid. The wall constitutes the white volume and the dosimetry is usually carried out starting from analytic formulas that only are valid in the case of an homogeneous media, uniform and infinite. In this work it is studied the dosimetry of the CQ by means of Monte Carlo simulation (MC), taking in account the different materials and interfaces that conform them. We present the obtained results for the radionuclide 186 Re. We have used the Monte Carlo code Penelope and we follow 5x10 6 histories in each simulation. We supposed a size of CQ of 1.75 cm of radio and a wall thickness of 1 mm and we have varied the constituent materials of the interior of the cyst and of the wall. The analytic calculations that we carry out show an excellent agreement with the MC results for an unique media (water), as much for the beta radiation as for those originated of the Rhenium disintegration. However, when it takes in account the gel that is introduced in the tumor for the treatment and we vary the constituent material of the wall, we find important differences. Of the analysis of our results we can conclude that the dosimetry for the treatment of CQ based in the usual analytic formulas overestimates the doses really deposited in the wall of the CQ. (Author)

  13. Separation and identification of Musa acuminate Colla (banana) leaf proteins by two-dimensional gel electrophoresis and mass spectrometry.

    Science.gov (United States)

    Lu, Y; Qi, Y X; Zhang, H; Zhang, H Q; Pu, J J; Xie, Y X

    2013-12-19

    To establish a proteomic reference map of Musa acuminate Colla (banana) leaf, we separated and identified leaf proteins using two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) and mass spectrometry (MS). Tryptic digests of 44 spots were subjected to peptide mass fingerprinting (PMF) by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS. Three spots that were not identified by MALDI-TOF MS analysis were identified by searching against the NCBInr, SwissProt, and expressed sequence tag (EST) databases. We identified 41 unique proteins. The majority of the identified leaf proteins were found to be involved in energy metabolism. The results indicate that 2D-PAGE is a sensitive and powerful technique for the separation and identification of Musa leaf proteins. A summary of the identified proteins and their putative functions is discussed.

  14. Multivariate data analysis of two-dimensional gel electrophoresis protein patterns from few samples

    DEFF Research Database (Denmark)

    Jensen, Kristina Nedenskov; Jessen, Flemming; Jørgensen, Bo

    2008-01-01

    One application of 2D gel electrophoresis is to reveal differences in protein pattern between two or more groups of individuals, attributable to their group membership. Multivariate data analytical methods are useful in pinpointing the spots relevant for discrimination by focusing not only...... on single spot differences, but on the covariance structure between proteins. However, their outcome is dependent on data scaling, and they may fail in producing valid multivariate models due to the much higher number of "irrelevant" spots present in the gels. The case where only few gels are available...... and where the aim is to find as many as possible of the group-dependent proteins seems particularly difficult to handle. The present paper investigates such a case regarding the effect of scaling and of prefiltering by univariate nonparametric statistics on the selection of spots. Besides, a modified...

  15. Poly(vinyl alcohol) gels as photoacoustic breast phantoms revisited.

    Science.gov (United States)

    Xia, Wenfeng; Piras, Daniele; Heijblom, Michelle; Steenbergen, Wiendelt; van Leeuwen, Ton G; Manohar, Srirang

    2011-07-01

    A popular phantom in photoacoustic imaging is poly(vinyl alcohol) (PVA) hydrogel fabricated by freezing and thawing (F-T) aqueous solutions of PVA. The material possesses acoustic and optical properties similar to those of tissue. Earlier work characterized PVA gels in small test specimens where temperature distributions during F-T are relatively homogeneous. In this work, in breast-sized samples we observed substantial temperature differences between the shallow regions and the interior during the F-T procedure. We investigated whether spatial variations were also present in the acoustic and optical properties. The speed of sound, acoustic attenuation, and optical reduced scattering coefficients were measured on specimens sampled at various locations in a large phantom. In general, the properties matched values quoted for breast tissue. But while acoustic properties were relatively homogeneous, the reduced scattering was substantially different at the surface compared with the interior. We correlated these variations with gel microstructure inspected using scanning electron microscopy. Interestingly, the phantom's reduced scattering spatial distribution matches the optical properties of the standard two-layer breast model used in x ray dosimetry. We conclude that large PVA samples prepared using the standard recipe make excellent breast tissue phantoms.

  16. Modern methods of personnel dosimetry

    International Nuclear Information System (INIS)

    Kraus, W.; Herrmann, D.; Kiesewetter, W.

    The physical properties of radiation detectors for personnel dosimetry are described and compared. The suitability of different types of dosimeters for operational and central monitoring of normal occupational exposure, for accident and catastrophe dosimetry and for background and space-flight dosimetry is discussed. The difficulties in interpreting the dosimeter reading with respect to the dose in individual body organs are discussed briefly. 430 literature citations (up to Spring 1966) are given

  17. Monochromatic minibeam radiotherapy: theoretical and experimental dosimetry for preclinical treatment plans

    Energy Technology Data Exchange (ETDEWEB)

    Deman, P; Vautrin, M; Stupar, V; Barbier, E L; Elleaume, H; Esteve, F; Adam, J F, E-mail: adam@esrf.fr [INSERM, U836, BP 170, Grenoble Cedex 9, F-38042 (France)

    2011-07-21

    Monochromatic x-ray minibeam radiotherapy is a new radiosurgery approach based on arrays of submillimetric interlaced planar x-ray beams. The aim of this study was to characterize the dose distributions obtained with this new modality when being used for preclinical trials. Monte Carlo simulations were performed in water phantoms. Percentage depth-dose curves and dose profiles were computed for single incidences and interleaved incidences of 80 keV planar x-ray minibeam (0.6 x 5 mm) arrays. Peak to valley dose ratios were also computed at various depths for an increasing number of minibeams. 3D experimental polymer gel (nPAG) dosimetry measurements were performed using MRI devices designed for small animal imaging. These very high spatial resolution (50 {mu}m) dose maps were compared to the simulations. Preclinical minibeams dose distributions were fully characterized. Experimental dosimetry correlated well with Monte Carlo calculations (Student t-tests: p > 0.1). F98 tumor-bearing rats were also irradiated with interleaved minibeams (80 keV, prescribed dose: 25 Gy). This associated preclinical trial serves as a proof of principle of the technique. The mean survival time of irradiated glioma-bearing rats increased significantly, when compared to the untreated animals (59.6 {+-} 2.8 days versus 28.25 {+-} 0.75 days, p < 0.001).

  18. Changes in protein abundance between tender and tough meat from bovine Longissimus thoracis muscle assessed by isobaric Tag for Relative and Absolute Quantitation (iTRAQ) and 2-dimensional gel electrophoresis analysis

    DEFF Research Database (Denmark)

    Bjarnadóttir, S G; Hollung, K; Høy, M

    2012-01-01

    The aim of this study was to find potential biomarkers for meat tenderness in bovine Longissimus thoracis muscle and to compare results from isobaric Tag for Relative and Absolute Quantitation (iTRAQ) and 2-dimensional gel electrophoresis (2-DE) analysis. The experiment included 4 tender and 4...

  19. Theoretical basis for dosimetry

    International Nuclear Information System (INIS)

    Carlsson, G.A.

    1985-01-01

    Radiation dosimetry is fundamental to all fields of science dealing with radiation effects and is concerned with problems which are often intricate as hinted above. A firm scientific basis is needed to face increasing demands on accurate dosimetry. This chapter is an attempt to review and to elucidate the elements for such a basis. Quantities suitable for radiation dosimetry have been defined in the unique work to coordinate radiation terminology and usage by the International Commission on Radiation Units and Measurements, ICRU. Basic definitions and terminology used in this chapter conform with the recent ''Radiation Quantities and Units, Report 33'' of the ICRU

  20. Three-dimensional illumination procedure for photodynamic therapy of dermatology

    Science.gov (United States)

    Hu, Xiao-ming; Zhang, Feng-juan; Dong, Fei; Zhou, Ya

    2014-09-01

    Light dosimetry is an important parameter that affects the efficacy of photodynamic therapy (PDT). However, the irregular morphologies of lesions complicate lesion segmentation and light irradiance adjustment. Therefore, this study developed an illumination demo system comprising a camera, a digital projector, and a computing unit to solve these problems. A three-dimensional model of a lesion was reconstructed using the developed system. Hierarchical segmentation was achieved with the superpixel algorithm. The expected light dosimetry on the targeted lesion was achieved with the proposed illumination procedure. Accurate control and optimization of light delivery can improve the efficacy of PDT.

  1. Fricke xylenol gel energy dependence

    International Nuclear Information System (INIS)

    Costa, Rosangela T.; Moreira, Marcos V.; Almeida, Adelaide de

    2009-01-01

    The advancement of technology has increasingly use the of ionizing radiation mainly in the areas of medicine, industry and research. The development of instruments and methods for an effective performance for detection and measurement of each radiation area was crucial. The literature have demonstrated the effectiveness of the Fricke Xylenol Gel (FXG) as an adequate chemical sensor to be used for dosimetry, once its effective atomic number and density are near to those of the soft tissue. The use of photon beams for therapeutic purpose requires knowledge of their characteristics that can vary for each equipment. Therefore, is important to know all parameters involved for the patient irradiation as the total geometry involved, type of radiation, target material composition and beam energy, that have to be taken into account in the beam dosimetry for the treatment success being the energy parameter is one of the most important. This work was developed to study the energetic dependence of the FXG dosimeter. This chemical solution is made with gelatine 300 Bloom, ferrous ammonium sulfate, xylenol orange, sulfuric acid and Milli-Q water and is based on the Fe +2 oxidation to Fe +3 , due to the ionizing radiation leading to the xylenol orange - ferric complex formation, that is linear depend on the absorbed dose. The FXG samples were irradiated with photons of different energies and the absorbance measurements were done with the spectrophotometric technique at the 585 nm, FXG highest absorption peak. The energetic dependence results presented a stronger dependence for low energies and almost independence for high energies, as expected by the interaction of radiation with matter. (author)

  2. Iron-based radiochromic systems for UV dosimetry applications

    Science.gov (United States)

    Lee, Hannah J.; Alqathami, Mamdooh; Blencowe, Anton; Ibbott, Geoffrey

    2018-01-01

    Phototherapy treatment using ultraviolet (UV) A and B light sources has long existed as a treatment option for various skin conditions. Quality control for phototherapy treatment recommended by the British Association of Dermatologists and British Photodermatology Group generally focused on instrumentation-based dosimetry measurements. The purpose of this study was to present an alternative, easily prepared dosimeter system for the measurement of UV dose and as a simple quality assurance technique for phototherapy treatments. Five different UVA-sensitive radiochromic dosimeter formulations were investigated and responded with a measurable and visible optical change both in solution and in gel form. Iron(III) reduction reaction formulations were found to be more sensitive to UVA compared to iron(II) oxidation formulations. One iron(III) reduction formulation was found to be especially promising due to its sensitivity to UVA dose, ease of production, and linear response up to a saturation point.

  3. User's manual of a supporting system for treatment planning in boron neutron capture therapy. JAERI computational dosimetry system

    Energy Technology Data Exchange (ETDEWEB)

    Kumada, Hiroaki; Torii, Yoshiya [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2002-09-01

    A boron neutron capture therapy (BNCT) with epithermal neutron beam is expected to treat effectively for malignant tumor that is located deeply in the brain. It is indispensable to estimate preliminarily the irradiation dose in the brain of a patient in order to perform the epithermal neutron beam BNCT. Thus, the JAERI Computational Dosimetry System (JCDS), which can calculate the dose distributions in the brain, has been developed. JCDS is a software that creates a 3-dimensional head model of a patient by using CT and MRI images and that generates a input data file automatically for calculation neutron flux and gamma-ray dose distribution in the brain by the Monte Carlo code: MCNP, and that displays the dose distribution on the head model for dosimetry by using the MCNP calculation results. JCDS has any advantages as follows; By treating CT data and MRI data which are medical images, a detail three-dimensional model of patient's head is able to be made easily. The three-dimensional head image is editable to simulate the state of a head after its surgical processes such as skin flap opening and bone removal for the BNCT with craniotomy that are being performed in Japan. JCDS can provide information for the Patient Setting System to set the patient in an actual irradiation position swiftly and accurately. This report describes basic design and procedure of dosimetry, operation manual, data and library structure for JCDS (ver.1.0). (author)

  4. Integration of gel-based and gel-free proteomic data for functional analysis of proteins through Soybean Proteome Database

    KAUST Repository

    Komatsu, Setsuko

    2017-05-10

    The Soybean Proteome Database (SPD) stores data on soybean proteins obtained with gel-based and gel-free proteomic techniques. The database was constructed to provide information on proteins for functional analyses. The majority of the data is focused on soybean (Glycine max ‘Enrei’). The growth and yield of soybean are strongly affected by environmental stresses such as flooding. The database was originally constructed using data on soybean proteins separated by two-dimensional polyacrylamide gel electrophoresis, which is a gel-based proteomic technique. Since 2015, the database has been expanded to incorporate data obtained by label-free mass spectrometry-based quantitative proteomics, which is a gel-free proteomic technique. Here, the portions of the database consisting of gel-free proteomic data are described. The gel-free proteomic database contains 39,212 proteins identified in 63 sample sets, such as temporal and organ-specific samples of soybean plants grown under flooding stress or non-stressed conditions. In addition, data on organellar proteins identified in mitochondria, nuclei, and endoplasmic reticulum are stored. Furthermore, the database integrates multiple omics data such as genomics, transcriptomics, metabolomics, and proteomics. The SPD database is accessible at http://proteome.dc.affrc.go.jp/Soybean/. Biological significanceThe Soybean Proteome Database stores data obtained from both gel-based and gel-free proteomic techniques. The gel-free proteomic database comprises 39,212 proteins identified in 63 sample sets, such as different organs of soybean plants grown under flooding stress or non-stressed conditions in a time-dependent manner. In addition, organellar proteins identified in mitochondria, nuclei, and endoplasmic reticulum are stored in the gel-free proteomics database. A total of 44,704 proteins, including 5490 proteins identified using a gel-based proteomic technique, are stored in the SPD. It accounts for approximately 80% of all

  5. Integration of gel-based and gel-free proteomic data for functional analysis of proteins through Soybean Proteome Database.

    Science.gov (United States)

    Komatsu, Setsuko; Wang, Xin; Yin, Xiaojian; Nanjo, Yohei; Ohyanagi, Hajime; Sakata, Katsumi

    2017-06-23

    The Soybean Proteome Database (SPD) stores data on soybean proteins obtained with gel-based and gel-free proteomic techniques. The database was constructed to provide information on proteins for functional analyses. The majority of the data is focused on soybean (Glycine max 'Enrei'). The growth and yield of soybean are strongly affected by environmental stresses such as flooding. The database was originally constructed using data on soybean proteins separated by two-dimensional polyacrylamide gel electrophoresis, which is a gel-based proteomic technique. Since 2015, the database has been expanded to incorporate data obtained by label-free mass spectrometry-based quantitative proteomics, which is a gel-free proteomic technique. Here, the portions of the database consisting of gel-free proteomic data are described. The gel-free proteomic database contains 39,212 proteins identified in 63 sample sets, such as temporal and organ-specific samples of soybean plants grown under flooding stress or non-stressed conditions. In addition, data on organellar proteins identified in mitochondria, nuclei, and endoplasmic reticulum are stored. Furthermore, the database integrates multiple omics data such as genomics, transcriptomics, metabolomics, and proteomics. The SPD database is accessible at http://proteome.dc.affrc.go.jp/Soybean/. The Soybean Proteome Database stores data obtained from both gel-based and gel-free proteomic techniques. The gel-free proteomic database comprises 39,212 proteins identified in 63 sample sets, such as different organs of soybean plants grown under flooding stress or non-stressed conditions in a time-dependent manner. In addition, organellar proteins identified in mitochondria, nuclei, and endoplasmic reticulum are stored in the gel-free proteomics database. A total of 44,704 proteins, including 5490 proteins identified using a gel-based proteomic technique, are stored in the SPD. It accounts for approximately 80% of all predicted proteins from

  6. Integration of gel-based and gel-free proteomic data for functional analysis of proteins through Soybean Proteome Database

    KAUST Repository

    Komatsu, Setsuko; Wang, Xin; Yin, Xiaojian; Nanjo, Yohei; Ohyanagi, Hajime; Sakata, Katsumi

    2017-01-01

    The Soybean Proteome Database (SPD) stores data on soybean proteins obtained with gel-based and gel-free proteomic techniques. The database was constructed to provide information on proteins for functional analyses. The majority of the data is focused on soybean (Glycine max ‘Enrei’). The growth and yield of soybean are strongly affected by environmental stresses such as flooding. The database was originally constructed using data on soybean proteins separated by two-dimensional polyacrylamide gel electrophoresis, which is a gel-based proteomic technique. Since 2015, the database has been expanded to incorporate data obtained by label-free mass spectrometry-based quantitative proteomics, which is a gel-free proteomic technique. Here, the portions of the database consisting of gel-free proteomic data are described. The gel-free proteomic database contains 39,212 proteins identified in 63 sample sets, such as temporal and organ-specific samples of soybean plants grown under flooding stress or non-stressed conditions. In addition, data on organellar proteins identified in mitochondria, nuclei, and endoplasmic reticulum are stored. Furthermore, the database integrates multiple omics data such as genomics, transcriptomics, metabolomics, and proteomics. The SPD database is accessible at http://proteome.dc.affrc.go.jp/Soybean/. Biological significanceThe Soybean Proteome Database stores data obtained from both gel-based and gel-free proteomic techniques. The gel-free proteomic database comprises 39,212 proteins identified in 63 sample sets, such as different organs of soybean plants grown under flooding stress or non-stressed conditions in a time-dependent manner. In addition, organellar proteins identified in mitochondria, nuclei, and endoplasmic reticulum are stored in the gel-free proteomics database. A total of 44,704 proteins, including 5490 proteins identified using a gel-based proteomic technique, are stored in the SPD. It accounts for approximately 80% of all

  7. Initial proteome analysis of caffeine-induced proteins in Aspergillus tamarii using two-dimensional fluorescence difference gel electrophoresis.

    Science.gov (United States)

    Gutiérrez-Sánchez, Gerardo; Atwood, James; Kolli, V S Kumar; Roussos, Sévastianos; Augur, Christopher

    2012-04-01

    Caffeine is toxic to most microorganisms. However, some filamentous fungi, such as Aspergillus tamarii, are able to metabolize this alkaloid when fed caffeine as the sole nitrogen source. The aim of the present work was to identify intracellular A. tamarii proteins, regulated by caffeine, using fluorescence difference two-dimensional gel electrophoresis. Specific proteins from two culture media of A. tamarii grown either on ammonium sulfate or caffeine as the sole nitrogen source were analysed by mass spectrometry. Thirteen out of a total of 85 differentially expressed spots were identified after database search. Identified up-regulated proteins include phosphoglycerate kinase, malate dehydrogenase, dyp-type peroxidase family protein, heat shock protein, Cu, Zn superoxidase dismutase and xanthine dehydrogenase. Some of the proteins identified in this study are involved in the caffeine degradation pathway as well as in stress response, suggesting that stress proteins could be involved in caffeine metabolism in filamentous fungi.

  8. The master two-dimensional gel database of human AMA cell proteins: towards linking protein and genome sequence and mapping information (update 1991)

    DEFF Research Database (Denmark)

    Celis, J E; Leffers, H; Rasmussen, H H

    1991-01-01

    autoantigens" and "cDNAs". For convenience we have included an alphabetical list of all known proteins recorded in this database. In the long run, the main goal of this database is to link protein and DNA sequencing and mapping information (Human Genome Program) and to provide an integrated picture......The master two-dimensional gel database of human AMA cells currently lists 3801 cellular and secreted proteins, of which 371 cellular polypeptides (306 IEF; 65 NEPHGE) were added to the master images during the last 10 months. These include: (i) very basic and acidic proteins that do not focus...

  9. Personal dosimetry in Kazakhstan

    International Nuclear Information System (INIS)

    Khvoshnyanskaya, I.R.; Vdovichenko, V.G.; Lozbin, A.Yu.

    2003-01-01

    KATEP-AE Radiation Laboratory is the first organization in Kazakhstan officially licensed by the Kazakhstan Atomic Energy Committee to provide individual dosimetry services. The Laboratory was established according to the international standards. Nowadays it is the largest company providing personal dosimetry services in the Republic of Kazakhstan. (author)

  10. Status of neutron dosimetry cross sections

    International Nuclear Information System (INIS)

    Griffin, P.J.; Kelly, J.G.

    1992-01-01

    Several new cross section libraries, such as ENDF/B-VI(release 2), IRDF-90,JEF-2.2, and JENDL-3 Dosimetry, have recently been made available to the dosimetry community. the Sandia National Laboratories (SNL) Radiation Metrology Laboratory (RML) has worked with these libraries since pre-release versions were available. this paper summarizes the results of the intercomparison and testing of dosimetry cross sections. As a result of this analysis, a compendium of the best dosimetry cross sections was assembled from the available libraries for use within the SNL RML. this library, referred to as the SNLRML Library, contains 66 general dosimetry sensors and 3 special dosimeters unique to the RML sensor inventory. The SNLRML cross sections have been put into a format compatible with commonly used spectrum determination codes

  11. The use of apoptosis in human lymphocytes peripheral as alternative methods in biological dosimetry of radiation effects from cobalt-60

    International Nuclear Information System (INIS)

    Lemes, Marisa

    1997-01-01

    Gamma rays affect cells in dose-response manner, resulting in cell death, as in cancer radiotherapy. The ionizing radiation acts by transferring energy, mainly by free radicals from water radiolysis that result in nucleic acid damage and other effects in lipids and proteins, The level of exposure is indirectly estimated by physical dosimetry, but the biological dosimetry can measure the direct radiation effect, mainly in post-dividing cells by classical cytogenetic approach. Recently, it was reported that irradiated cells develop an induced programmed death or apoptosis. With a biological dosimetric technique, we measured apoptotic cell fraction in 60 Co in vitro irradiated blood cells from voluntary healthy donors. The agarose gel electrophoresis showed a low sensitivity, because cell DNA presented the characteristic pattern only when the cells were exposed to 100 c Gy or more. Using a terminal DNA labeling technique we observed that the apoptotic cell fraction proportionally increases with irradiation. Similar sensitivity was observed when compared to classical cytogenetics (3 c Gy minimum detection level). These techniques are easier to perform, do not need cell culture and all cells, including interphase ones, can be analyzed, providing a good tool in biological dosimetry. (author)

  12. Dosimetry and shielding

    International Nuclear Information System (INIS)

    Farinelli, U.

    1977-01-01

    Today, reactor dosimetry and shielding have wide areas of overlap as concerns both problems and methods. Increased interchange of results and know-how would benefit both. The areas of common interest include calculational methods, sensitivity studies, theoretical and experimental benchmarks, cross sections and other nuclear data, multigroup libraries and procedures for their adjustment, experimental techniques and damage functions. This paper reviews the state-of-the-art and the latest development in each of these areas as far as shielding is concerned, and suggests a number of interactions that could be profitable for reactor dosimetry. Among them, re-evaluation of the potentialities of calculational methods (in view of the recent developments) in predicting radiation environments of interest; the application of sensitivity analysis to dosimetry problems; a common effort in the field of theoretical benchmarks; the use of the shielding one-material propagation experiments as reference spectra for detector cross sections; common standardization of the detector nuclear data used in both fields; the setting up of a common (or compatible) multigroup structure and library applicable to shielding, dosimetry and core physics; the exchange of information and experience in the fields of cross section errors, correlations and adjustment; and the intercomparison of experimental techniques

  13. The Latin American Biological Dosimetry Network (LBDNet)

    International Nuclear Information System (INIS)

    Garcia, O.; Lamadrid, A.I.; Gonzalez, J.E.; Romero, I.; Mandina, T.; Di Giorgio, M.; Radl, A.; Taja, M.R.; Sapienza, C.E.; Deminge, M.M.; Fernandez Rearte, J.; Stuck Oliveira, M.; Valdivia, P.; Guerrero-Carbajal, C.; Arceo Maldonado, C.; Cortina Ramirez, G.E.; Espinoza, M.; Martinez-Lopez, W.; Di Tomasso, M.

    2016-01-01

    Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. (authors)

  14. Therapeutic Potential of Human Adipose-Derived Stem/Stromal Cell Microspheroids Prepared by Three-Dimensional Culture in Non-Cross-Linked Hyaluronic Acid Gel.

    Science.gov (United States)

    Mineda, Kazuhide; Feng, Jingwei; Ishimine, Hisako; Takada, Hitomi; Doi, Kentaro; Kuno, Shinichiro; Kinoshita, Kahori; Kanayama, Koji; Kato, Harunosuke; Mashiko, Takanobu; Hashimoto, Ichiro; Nakanishi, Hideki; Kurisaki, Akira; Yoshimura, Kotaro

    2015-12-01

    Three-dimensional culture of mesenchymal stem/stromal cells for spheroid formation is known to enhance their therapeutic potential for regenerative medicine. Spheroids were prepared by culturing human adipose-derived stem/stromal cells (hASCs) in a non-cross-linked hyaluronic acid (HA) gel and compared with dissociated hASCs and hASC spheroids prepared using a nonadherent dish. Preliminary experiments indicated that a 4% HA gel was the most appropriate for forming hASC spheroids with a relatively consistent size (20-50 µm) within 48 hours. Prepared spheroids were positive for pluripotency markers (NANOG, OCT3/4, and SOX-2), and 40% of the cells were SSEA-3-positive, a marker of the multilineage differentiating stress enduring or Muse cell. In contrast with dissociated ASCs, increased secretion of cytokines such as hepatocyte growth factor was detected in ASC spheroids cultured under hypoxia. On microarray ASC spheroids showed upregulation of some pluripotency markers and downregulation of genes related to the mitotic cell cycle. After ischemia-reperfusion injury to the fat pad in SCID mice, local injection of hASC spheroids promoted tissue repair and reduced the final atrophy (1.6%) compared with that of dissociated hASCs (14.3%) or phosphate-buffered saline (20.3%). Part of the administered hASCs differentiated into vascular endothelial cells. ASC spheroids prepared in a HA gel contain undifferentiated cells with therapeutic potential to promote angiogenesis and tissue regeneration after damage. This study shows the therapeutic value of human adipose-derived stem cell spheroids prepared in hyarulonic acid gel. The spheroids have various benefits as an injectable cellular product and show therapeutic potential to the stem cell-depleted conditions such as diabetic chronic skin ulcer. ©AlphaMed Press.

  15. Enhanced removal of detergent and recovery of enzymatic activity following sodium dodecyl sulfate-polyacrylamide gel electrophoresis: UUse of casein in gel wash buffer

    International Nuclear Information System (INIS)

    McGrew, B.R.; Green, D.M.

    1990-01-01

    The inclusion of 1% casein or bovine serum albumin in buffer used to reactivate enzymes subjected to sodium dodecyl sulfate (SDS)-polyacrylamide electrophoresis resulted in accelerated removal of SDS and restoration of nuclease and beta-galactosidase enzyme activities. Nuclease and beta-galactosidase activities which are absent from gels after longer wash procedures are detectable with this technique. Enzyme activity in gels prepared with SDS which contained inhibitory contaminants was partially restored by the casein wash procedure. The threshold of detection of two-dimensionally separated deoxyribonuclease I using the casein wash procedure was 1 picogram

  16. Transmission dosimetry with a liquid-filled electronic portal imaging device

    Energy Technology Data Exchange (ETDEWEB)

    Boellaard, R; Van Herk, M; Mijnheer, B J [Nederlands Kanker Inst. ` Antoni van Leeuwenhoekhuis` , Amsterdam (Netherlands)

    1995-12-01

    The aim of transmission dosimetry is to correlate transmission dose values with patient dose values. A liquid-filled electronic portal imaging device (EPID) has been developed. After determination of the dose response relationship, i.e. the relation between pixel value and dose rate, for clinical situations it was found that the EPID is applicable for two-dimensional dosimetry with an accuracy of about 1%. The aim of this study was to investigate transmission dose distributions at different phantom-detector distances to predict exit dose distributions from transmission dose images. An extensive set of transmission dose measurements below homogeneous phantoms were performed with the EPID. The influence of several parameters such as field size, phantom thickness, phantom-detector distance and phantom-source distance on the transmission dose and its distribution were investigated. The two-dimensional transmission dose images were separated into two components: a primary dose and a scattered dose distribution. It was found that the scattered dose is maximal at a phantom thickness of about 10 cm. The scattered dose distribution below a homogeneous phantom has a Gaussian shape. The width of the Gaussian is small at small phantom-detector distances and increases for larger phantom-detector distances. The dependence of the scattered dose distribution on the field size at various phantom-detector distances has been used to estimate the dose distribution at the exit site of the phantom. More work is underway to determine the exit dose distributions for clinical situations, including the presence of inhomogeneities.

  17. Transmission dosimetry with a liquid-filled electronic portal imaging device

    International Nuclear Information System (INIS)

    Boellaard, R.; Van Herk, M.; Mijnheer, B.J.

    1995-01-01

    The aim of transmission dosimetry is to correlate transmission dose values with patient dose values. A liquid-filled electronic portal imaging device (EPID) has been developed. After determination of the dose response relationship, i.e. the relation between pixel value and dose rate, for clinical situations it was found that the EPID is applicable for two-dimensional dosimetry with an accuracy of about 1%. The aim of this study was to investigate transmission dose distributions at different phantom-detector distances to predict exit dose distributions from transmission dose images. An extensive set of transmission dose measurements below homogeneous phantoms were performed with the EPID. The influence of several parameters such as field size, phantom thickness, phantom-detector distance and phantom-source distance on the transmission dose and its distribution were investigated. The two-dimensional transmission dose images were separated into two components: a primary dose and a scattered dose distribution. It was found that the scattered dose is maximal at a phantom thickness of about 10 cm. The scattered dose distribution below a homogeneous phantom has a Gaussian shape. The width of the Gaussian is small at small phantom-detector distances and increases for larger phantom-detector distances. The dependence of the scattered dose distribution on the field size at various phantom-detector distances has been used to estimate the dose distribution at the exit site of the phantom. More work is underway to determine the exit dose distributions for clinical situations, including the presence of inhomogeneities

  18. Internal dosimetry, past and future

    International Nuclear Information System (INIS)

    Johnson, J.R.

    1989-03-01

    This paper is a review of the progress in the dosimetry of internally deposited radionuclides (internal dosimetry) since World War II. Previous to that, only naturally occurring radionuclides were available and only a limited number of studies of biokinetics and dosimetry were done. The main radionuclides studied were 226 Ra, 228 Ra, and 224 Ra but natural uranium was also studied mainly because of its toxic effect as a heavy metal, and not because it was radioactive. The effects of 226 Ra in bone, mainly from the radium dial painters, also formed the only bases for the radiotoxicity of radionuclides in bone for many years, and it is still, along with 224 Ra, the main source of information on the effects of alpha emitters in bone. The publications of the International Commission on Radiological Protection that have an impact on internal dosimetry are used as mileposts for this review. These series of publications, more than any other, represent a broad consensus of opinion within the radiation protection community at the time of their publication, and have formed the bases for radiation protection practice throughout the world. This review is not meant to be exhaustive; it is meant to be a personnel view of the evolution of internal dosimetry, and to present the author's opinion of what the future directions in internal dosimetry will be. 39 refs., 2 tabs

  19. Individual neutron dosimetry

    International Nuclear Information System (INIS)

    Mauricio, C.L.P.

    1987-01-01

    The most important concepts and development in individual neutron dosimetry are presented, especially the dosimetric properties of the albedo technique. The main problem in albedo dosimetry is to calibrate the dosemeter in the environs of each neutron source. Some of the most used calibration techniques are discussed. The IRD albedo dosemeter used in the routine neutron individual monitoring is described in detail. Its dosimetric properties and calibration methods are discussed. (Author) [pt

  20. An evaluation of the dosimetric performance characteristics of N-vinylpyrrolidone-based polymer gels

    Energy Technology Data Exchange (ETDEWEB)

    Papadakis, A E [Department of Medical Physics, Faculty of Medicine, University of Crete, PO Box 2208, Iraklion 71003, Crete (Greece); Maris, T G [Department of Medical Physics, Faculty of Medicine, University of Crete, PO Box 2208, Iraklion 71003, Crete (Greece); Zacharopoulou, F [Department of Medical Physics, Faculty of Medicine, University of Crete, PO Box 2208, Iraklion 71003, Crete (Greece); Pappas, E [Department of Medical Physics, Faculty of Medicine, University of Crete, PO Box 2208, Iraklion 71003, Crete (Greece); Zacharakis, G [Institute of Electronic Structure and Laser (IESL), Foundation for Research and Technology-Hellas (FORTH), PO Box 1527, Iraklion, Crete (Greece); Damilakis, J [Department of Medical Physics, Faculty of Medicine, University of Crete, PO Box 2208, Iraklion 71003, Crete (Greece)

    2007-08-21

    The aim of this work was to investigate the dosimetric performance properties of the N-vinylpyrrolidone argon (VIPAR) based polymer gel as a dosimetric tool in clinical radiotherapy. VIPAR gels with a larger concentration of gelatin than the standard recipe were manufactured and irradiated up to 68 Gy using a 6 and 18 MV linear accelerator. Using MRI, the R2-dose response was recorded at different imaging sessions within a 34 day time period post-irradiation. The R2-dose response was found to be linear between 5 and 68 Gy. Although dose sensitivity did not show significant variation with time, the measured R2-dose values showed an increasing trend, which was less evident beyond 17 days. At one day post-irradiation, calculated dose standard uncertainties at 20 Gy and 56 Gy were 2.2% and 1.7%, providing a dose resolution of 0.45 Gy and 0.97 Gy, respectively. Although these values fulfilled the 2% limit of ICRU, when gels were imaged at one day post-irradiation, it was shown that the temporal evolution of the R2 values deteriorated the per cent standard uncertainty and the dose resolution by {approx}57%, when imaged 17 days post-irradiation. Variation in the coagulation temperature of the gels did not impact the R2-dose sensitivity. This study has shown that the VIPAR gel has the properties of a dosimetric tool required in clinical radiotherapy, especially in applications where a wide dose dynamic range is employed. For results with the lowest per cent uncertainty and the optimum dose resolution, the dosimetry gels used in this work should be MR scanned at one day post-irradiation. Furthermore, a preliminary study on the R2-dose response of a new normoxic N-vinylpyrrolidone-based polymer gel showed that it could potentially replace the traditional VIPAR gel formulation, while preserving the wide dynamic dose response inherent to that monomer.

  1. Advantages and disadvantages of luminescence dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Olko, Pawel, E-mail: Pawel.Olko@ifj.edu.p [Institute of Nuclear Physics Polish Academy of Science (IFJ PAN), Krakow (Poland)

    2010-03-15

    Owing to their excellent dosimetric properties, luminescence detectors of ionizing radiation are now extensively applied in individual dosimetry services. The most frequently used personal dosemeters are based on Optically Stimulated Luminescence (OSL), radiophotoluminescence (RPL) or thermoluminescence (TL). Luminescence detectors have also found several applications in clinical dosimetry, especially around new radiation modalities in radiotherapy, such as Intensity Modulated Radiotherapy (IMRT) or ion beam radiotherapy. Requirements of luminescence detectors applied in individual and clinical dosimetry and some recent developments in luminescence of detectors and techniques leading to significant improvements of the functionality and accuracy of dosimetry systems are reviewed and discussed.

  2. Swimming micro-robot powered by stimuli-sensitive gel

    Science.gov (United States)

    Masoud, Hassan; Alexeev, Alexander

    2012-11-01

    Using three-dimensional computer simulations, we design a simple maneuverable micro-swimmer that can self-propel and navigate in highly viscous (low Reynolds-number) environments. Our simple swimmer consists of a cubic gel body which periodically changes volume in response to external stimuli, two rigid rectangular flaps attached to the opposite sides of the gel body, and a flexible steering flap at the front end of the swimmer. The stimuli-sensitive body undergoes periodic expansions (swelling) and contractions (deswelling) leading to a time-irreversible beating motion of the propulsive flaps that propel the micro-swimmer. Thus, the responsive gel body acts as an ``engine'' actuating the motion of the swimmer. We examine how the swimming speed depends on the gel and flap properties. We also probe how the swimmer trajectory can be changed using a responsive steering flap whose curvature is controlled by an external stimulus. We show that the turning occurs due to steering flap bending and periodic beating. Furthermore, our simulations reveal that the turning direction can be regulated by changing the intensity of external stimulus.

  3. Technical Note: Preliminary investigations into the use of a functionalised polymer to reduce diffusion in Fricke gel dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S. T., E-mail: s164.smith@qut.edu.au; Masters, K.-S.; Hosokawa, K.; Blinco, J. P.; Trapp, J. V. [School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane 4000 (Australia); Crowe, S. B. [School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane 4000, Australia and Cancer Care Services, Royal Brisbane and Women’s Hospital, Brisbane 4006 (Australia); Kairn, T. [School of Chemistry, Physics and Mechanical Engineering, Queensland University of Technology, Brisbane 4000, Australia and Genesis Cancer Care Queensland, Brisbane 4066 (Australia)

    2015-12-15

    Purpose: A modification of the existing PVA-FX hydrogel has been made to investigate the use of a functionalised polymer in a Fricke gel dosimetry system to decrease Fe{sup 3+} diffusion. Methods: The chelating agent, xylenol orange, was chemically bonded to the gelling agent, polyvinyl alcohol (PVA) to create xylenol orange functionalised PVA (XO-PVA). A gel was created from the XO-PVA (20% w/v) with ferrous sulfate (0.4 mM) and sulfuric acid (50 mM). Results: This resulted in an optical density dose sensitivity of 0.014 Gy{sup −1}, an auto-oxidation rate of 0.0005 h{sup −1}, and a diffusion rate of 0.129 mm{sup 2} h{sup −1}; an 8% reduction compared to the original PVA-FX gel, which in practical terms adds approximately 1 h to the time span between irradiation and accurate read-out. Conclusions: Because this initial method of chemically bonding xylenol orange to polyvinyl alcohol has inherently low conversion, the improvement on existing gel systems is minimal when compared to the drawbacks. More efficient methods of functionalising polyvinyl alcohol with xylenol orange must be developed for this system to gain clinical relevance.

  4. Accidental and retrospective dosimetry using TL method

    International Nuclear Information System (INIS)

    Mesterházy, D.; Osvay, M.; Kovács, A.; Kelemen, A.

    2012-01-01

    Retrospective dosimetry is one of the most important tools of accidental dosimetry for dose estimation when dose measurement was not planned. In the affected area many objects can be applied as natural dosimeters. The paper discusses our recent investigations on various electronic components and common salt (NaCl) having useful thermoluminescence (TL) properties. Among materials investigated the electronic components of cell phones seem promising for retrospective dosimetry purposes, having high TL responses, proper glow curve peaks and the intensity of TL peaks vs. gamma dose received provided nearly linear response in the dose range of 10 mGy–1.5 Gy. - Highlights: ► Electronic components and common salt were investigated for accidental and retrospective dosimetry. ► SMD resistors seem promising for retrospective dosimetry purposes. ► Table salt can be used effectively for accidental dosimetry purposes, as well.

  5. A modified Fricke gel dosimeter for fast electron blood dosimetry

    International Nuclear Information System (INIS)

    Del Lama, L.S.; Góes, E.G. de; Sampaio, F.G.A.; Petchevist, P.C.D.; Almeida, A. de

    2014-01-01

    It has been suggested for more than forty years that blood and blood components be irradiated before allogeneic transfusions for immunosuppressed patients in order to avoid the Transfusion-Associated Graft-versus-Host Disease (TA-GVHD). Whole blood, red blood cells, platelets and granulocytes may have viable T cells and should be irradiated before transfusion for different patient clinical conditions. According to international guides, absorbed doses from 25 up to 50 Gy should be delivered to the central middle plane of each blood bag. Although gamma and X-rays from radiotherapy equipments and dedicated cell irradiators are commonly used for this purpose, electron beams from Linear Accelerators (LINACs) could be used as well. In this work, we developed a methodology able to acquire dosimetric data from blood irradiations, especially after fast electrons exposures. This was achieved using a proposed Fricke Xylenol Gel (FXG p ) dosimeter, which presents closer radiological characteristics (attenuation coefficients and stopping-powers) to the whole blood, as well as complete absorbed dose range linearity. The developed methodology and the FXG p dosimeter were also able to provide isodose curves and field profiles for the irradiated samples

  6. A modified Fricke gel dosimeter for fast electron blood dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Del Lama, L.S., E-mail: lucasdellama@gmail.com [Departamento de Fsica, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo (FFCLRP/USP), Av. Bandeirantes, 3900, CEP 14040-901, Bairro Monte Alegre, Ribeirão Preto, São Paulo (Brazil); Góes, E.G. de [Instituto de Matemática, Estatística e Física, Universidade Federal de Rio Grande (IMEF/FURG), Av. Itália, km 8, CEP 96201-900, Bairro Carreiros, Rio Grande, Rio Grande do Sul (Brazil); Sampaio, F.G.A.; Petchevist, P.C.D.; Almeida, A. de [Departamento de Fsica, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo (FFCLRP/USP), Av. Bandeirantes, 3900, CEP 14040-901, Bairro Monte Alegre, Ribeirão Preto, São Paulo (Brazil)

    2014-12-15

    It has been suggested for more than forty years that blood and blood components be irradiated before allogeneic transfusions for immunosuppressed patients in order to avoid the Transfusion-Associated Graft-versus-Host Disease (TA-GVHD). Whole blood, red blood cells, platelets and granulocytes may have viable T cells and should be irradiated before transfusion for different patient clinical conditions. According to international guides, absorbed doses from 25 up to 50 Gy should be delivered to the central middle plane of each blood bag. Although gamma and X-rays from radiotherapy equipments and dedicated cell irradiators are commonly used for this purpose, electron beams from Linear Accelerators (LINACs) could be used as well. In this work, we developed a methodology able to acquire dosimetric data from blood irradiations, especially after fast electrons exposures. This was achieved using a proposed Fricke Xylenol Gel (FXG{sub p}) dosimeter, which presents closer radiological characteristics (attenuation coefficients and stopping-powers) to the whole blood, as well as complete absorbed dose range linearity. The developed methodology and the FXG{sub p} dosimeter were also able to provide isodose curves and field profiles for the irradiated samples.

  7. Dosimetry and Calibration Section

    International Nuclear Information System (INIS)

    Otto, T.

    1998-01-01

    The two tasks of the Dosimetry and Calibration Section at CERN are the Individual Dosimetry Service which assures the personal monitoring of about 5000 persons potentially exposed to ionizing radiation at CERN, and the Calibration Laboratory which verifies all the instruments and monitors. This equipment is used by the sections of the RP Group for assuring radiation protection around CERN's accelerators, and by the Environmental Section of TISTE. In addition, nearly 250 electronic and 300 quartz fibre dosimeters, employed in operational dosimetry, are calibrated at least once a year. The Individual Dosimetry Service uses an extended database (INDOS) which contains information about all the individual doses ever received at CERN. For most of 1997 it was operated without the support of a database administrator as the technician who had assured this work retired. The Software Support Section of TIS-TE took over the technical responsibility of the database, but in view of the many other tasks of this Section and the lack of personnel, only a few interventions for solving immediate problems were possible

  8. Personal dosimetry service of VF, a.s. company

    International Nuclear Information System (INIS)

    Prasek, P.

    2009-01-01

    The VF, a.s. Company will extend its services in the area of personal dosimetry at the end of 2008, which is fully in compliance with the requirements of the Atomic Act, section 9 paragraph (1) letter r) and Decree on Radiation Protection, section 59 paragraph (1) letter a). Optically stimulated luminescence was selected in VF .a.s. as the most advantageous and the most advanced technology for the integral personal dosimetry. Optically stimulated luminescence (OSL) has been using in dosimetry for more than ten years. Although it is relatively new technology , its indisputable advantages predetermine that technology has significantly benefited in personal dosimetry services within a short time all over the advanced world. The VF, a.s. personal dosimetry service is based on the licensed products of LANDAUER, the US company, which is the world leader in OSL dosimetry. Crystalline Al 2 O 3 :C was selected as the detection material. All equipment of personal dosimetry service is installed in the VF Centre of Technology in Cerna Hora. The personal dosimetry service is incorporated in the International LANDAUER Dosimetry Service Network, and in the European Union, it is directly linked to the LANDAUER European Headquarters with its office in Paris. As a part of the OSL technology licence, the VF personal dosimetry service was included in the inter-laboratory comparison programme of the LANDAUER syndicate. (author)

  9. Personal dosimetry service of VF, a.s. company

    International Nuclear Information System (INIS)

    Prasek, P.

    2008-01-01

    The VF, a.s. Company will extend its services in the area of personal dosimetry at the end of 2008, which is fully in compliance with the requirements of the Atomic Act, section 9 paragraph (1) letter r) and Decree on Radiation Protection, section 59 paragraph (1) letter a). Optically stimulated luminescence was selected in VF .a.s. as the most advantageous and the most advanced technology for the integral personal dosimetry . Optically stimulated luminescence (OSL) has been using in dosimetry for more than ten years. Although it is relatively new technology , its indisputable advantages predetermine that technology has significantly benefited in personal dosimetry services within a short time all over the advanced world. The VF, a.s. personal dosimetry service is based on the licensed products of LANDAUER, the US company, which is the world leader in OSL dosimetry. Crystalline Al 2 O 3 :C was selected as the detection material. All equipment of personal dosimetry service is installed in the VF Centre of Technology in Cerna Hora. The personal dosimetry service is incorporated in the International LANDAUER Dosimetry Service Network, and in the European Union, it is directly linked to the LANDAUER European Headquarters with its office in Paris. As a part of the OSL technology licence, the VF personal dosimetry service was included in the inter-laboratory comparison programme of the LANDAUER syndicate. (author)

  10. Neutron personal dosimetry: state-of-art

    International Nuclear Information System (INIS)

    Spurný, František

    2005-03-01

    State-of-art of the personal neutron dosimetry is presented, analysed and discussed. Particular attention is devoted to the problems of this type of the dosimetry of external exposure for radiation fields at nuclear power plants. A review of general problems of neutron dosimetry is given and the active individual dosimetry methods available and/or in the stage of development are briefly reviewed. Main attention is devoted to the analysis of the methods available for passive individual neutron dosimetry. The characteristics of these dosemeters were studied and are compared: their energy response functions, detection thresholds and the highest detection limits, the linearity of response, the influence of environmental factors, etc. Particular attention is devoted to their behavior in reactor neutron fields. It is concluded that the choice of the neutron personal dosemeter depends largely on the conditions in which the instrument should be used (neutron spectrum, the level of exposure and the exposure rate, etc.). The results obtained with some of these dosemeters during international intercomparisons are also presented. Particular attention is paid to the personal neutron dosimeter developed and routinely used by National Personal Dosimetry Service Ltd. in the Czech Republic. (author)

  11. Proteomic analysis of differential protein expression of achilles tendon in a rabbit model by two-dimensional polyacrylamide gel electrophoresis at 21 days postoperation.

    Science.gov (United States)

    Jielile, Jiasharete; Jialili, Ainuer; Sabirhazi, Gulnur; Shawutali, Nuerai; Redati, Darebai; Chen, Jiangtao; Tang, Bin; Bai, Jingping; Aldyarhan, Kayrat

    2011-10-01

    Postoperative early kinesitherapy has been advocated as an optimal method for treating Achilles tendon rupture. However, an insight into the rationale of how early kinesitherapy contributes to healing of Achilles tendon remains to be achieved, and research in the area of proteomic analysis of Achilles tendon has so far been lacking. Forty-two rabbits were randomized into control group, immobilization group, and early motion group, and received postoperative cast immobilization and early motion treatments. Achilles tendon samples were prepared 21 days following microsurgery, and the proteins were separated with two-dimensional polyacrylamide gel electrophoresis. Differentially expressed proteins were first recognized by PDQuest software, and then identified using peptide mass fingerprinting, tandem mass spectrometry, and database searching. A total of 463  ±  12, 511  ±  39, and 513  ±  80 protein spots were successfully detected in the two-dimensional polyacrylamide gels for the Achilles tendon samples of rabbits in the control group, immobilization group, and early motion group, respectively. There were 15, 8, and 9 unique proteins in these three groups, respectively, and some differentially expressed proteins were also identified in each group. It was indicated that some of the differentially expressed proteins were involved in various metabolism pathways and may play an important role in healing of Achilles tendon rupture. Postoperative early kinesitherapy resulted in differentially expressed proteins in ruptured Achilles tendon compared with those treated with postoperative cast immobilization. These differentially expressed proteins may contribute to healing of Achilles tendon rupture through a mechanobiological mechanism due to the application of postoperative early kinesitherapy.

  12. Preliminary study of diffusion effects in Fricke gel dosimeters

    International Nuclear Information System (INIS)

    Quiroga, A.; Vedelago, J.; Valente, M.

    2014-08-01

    in standard dependence of optical density differences and actual, non-diffused, absorbed dose distributions. The obtained values for ferric ion diffusion coefficient, in mm 2 h -1 were (1.24 ± 0.07) and (1.15 ± 0.05) for the 1D and 2D method, respectively, in the first approach method and (0.65 ± 0.01), (0.68 ± 0.02) and (0.65 ± 0.02) in the second approach method. The results show good agreement with previous works corresponding to similar Fricke gel dosimeter compositions. Thus, more accurate 2D and 3D dose mapping might be attained that constitutes valuable improvements in Fricke gel dosimetry, and parallel a high precision methods of diffusion model and calculation have been developed. (Author)

  13. Development and characterization of a three-dimensional radiochromic film stack dosimeter for megavoltage photon beam dosimetry.

    Science.gov (United States)

    McCaw, Travis J; Micka, John A; DeWerd, Larry A

    2014-05-01

    Three-dimensional (3D) dosimeters are particularly useful for verifying the commissioning of treatment planning and delivery systems, especially with the ever-increasing implementation of complex and conformal radiotherapy techniques such as volumetric modulated arc therapy. However, currently available 3D dosimeters require extensive experience to prepare and analyze, and are subject to large measurement uncertainties. This work aims to provide a more readily implementable 3D dosimeter with the development and characterization of a radiochromic film stack dosimeter for megavoltage photon beam dosimetry. A film stack dosimeter was developed using Gafchromic(®) EBT2 films. The dosimeter consists of 22 films separated by 1 mm-thick spacers. A Virtual Water™ phantom was created that maintains the radial film alignment within a maximum uncertainty of 0.3 mm. The film stack dosimeter was characterized using simulations and measurements of 6 MV fields. The absorbed-dose energy dependence and orientation dependence of the film stack dosimeter were investigated using Monte Carlo simulations. The water equivalence of the dosimeter was determined by comparing percentage-depth-dose (PDD) profiles measured with the film stack dosimeter and simulated using Monte Carlo methods. Film stack dosimeter measurements were verified with thermoluminescent dosimeter (TLD) microcube measurements. The film stack dosimeter was also used to verify the delivery of an intensity-modulated radiation therapy (IMRT) procedure. The absorbed-dose energy response of EBT2 film differs less than 1.5% between the calibration and film stack dosimeter geometries for a 6 MV spectrum. Over a series of beam angles ranging from normal incidence to parallel incidence, the overall variation in the response of the film stack dosimeter is within a range of 2.5%. Relative to the response to a normally incident beam, the film stack dosimeter exhibits a 1% under-response when the beam axis is parallel to the film

  14. The jellyfish and its polyp: a comparative study of gene expression monitored by the protein patterns using two-dimensional gels with double-label autoradiography

    International Nuclear Information System (INIS)

    Bally, Andreas; Schmid, Volker

    1988-01-01

    The life cycle of Podocoryne carnea (Coelenterata. Anthomedusae) shows several distinct stages which differ considerably in terms of their ecology, morphology, cellular composition and ultra structure. Using two-dimensional gel electrophoresis and a new method of double-label autoradiography, we show here for the first time for metagenic hydrozoans that only minor differences in gene expression exist between the various life cycle stages. Our results demonstrate the high resolution power of these techniques and show that the different life stages of P. carnea remain rather similar on the protein level (author)

  15. Internal dosimetry technical basis manual

    International Nuclear Information System (INIS)

    1990-01-01

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophical discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs

  16. Internal dosimetry technical basis manual

    Energy Technology Data Exchange (ETDEWEB)

    1990-12-20

    The internal dosimetry program at the Savannah River Site (SRS) consists of radiation protection programs and activities used to detect and evaluate intakes of radioactive material by radiation workers. Examples of such programs are: air monitoring; surface contamination monitoring; personal contamination surveys; radiobioassay; and dose assessment. The objectives of the internal dosimetry program are to demonstrate that the workplace is under control and that workers are not being exposed to radioactive material, and to detect and assess inadvertent intakes in the workplace. The Savannah River Site Internal Dosimetry Technical Basis Manual (TBM) is intended to provide a technical and philosophical discussion of the radiobioassay and dose assessment aspects of the internal dosimetry program. Detailed information on air, surface, and personal contamination surveillance programs is not given in this manual except for how these programs interface with routine and special bioassay programs.

  17. Dosimetry systems for radiation processing

    International Nuclear Information System (INIS)

    McLaughlin, W.L.; Desrosiers, M.F.

    1995-01-01

    Dosimetry serves important functions in radiation processing, where large absorbed doses and dose rates from photon and electron sources have to be measured with reasonable accuracy. Proven dosimetry systems are widely used to perform radiation measurements in development of new processes, validation, qualification and verification (quality control) of established processes and archival documentation of day-to-day and plant-to-plant processing uniformity. Proper calibration and traceability of routine dosimetry systems to standards are crucial to the success of many large-volume radiation processes. Recent innovations and advances in performance of systems that enhance radiation measurement assurance and process diagnostics include dose-mapping media (new radiochromic film and solutions), optical waveguide systems for food irradiation, solid-state devices for real-time and passive dosimetry over wide dose-rate and dose ranges, and improved analytical instruments and data acquisition. (author)

  18. Individual dosimetry of workers and patients: implementation and perspectives; La dosimetrie individuelle des travailleurs et de patients: mise en oeuvre et perspectives

    Energy Technology Data Exchange (ETDEWEB)

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E

    2008-07-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  19. Sequence Dependent Electrophoretic Separations of DNA in Pluronic F127 Gels

    Science.gov (United States)

    You, Seungyong; van Winkle, David H.

    2010-03-01

    Two-dimensional (2-D) electrophoresis has successfully been used to visualize the separation of DNA fragments of the same length. We electrophorese a double-stranded DNA ladder in an Agarose gel for the first dimension and in gels of Pluronic F127 for the second dimension at room temperature. The 1000 bp band that travels together as a single band in an Agarose gel is split into two bands in Pluronic gels. The slower band follows the exponential decay trend that the other ladder constituents do. After sequencing the DNA fragments, the faster band has an apparently random sequence, while the slower band and the others have two A-tracts in each 250 bp segment. The A-tracts consist of a series of at least five adenine bases pairing with thymine bases. This result leads to the conclusion that the migration of the DNA molecules bent with A-tracts is more retarded in Pluronic gels than the wild-type of DNA molecules.

  20. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    Please note the following opening hours of the Service: From 31st July onwards: Every morning from 8:30 to 12:00 The Service is closed in the afternoons. We should like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCTs) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel 72155 Bldg. 24 E 011 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  1. Specific proteins synthesized during the viral lytic cycle in vaccinia virus-infected HeLa cells: analysis by high-resolution, two-dimensional gel electrophoresis

    International Nuclear Information System (INIS)

    Carrasco, L.; Bravo, R.

    1986-01-01

    The proteins synthesized in vaccinia-infected HeLa cells have been analyzed at different times after infection by using two-dimensional gel electrophoresis. Vaccinia-infected cells present up to 198 polypeptides (138 acidic, isoelectric focusing; 60 basic, nonequilibrium pH gradient electrophoresis) not detected in control cells. Cells infected in the presence of cycloheximide show 81 additional polypeptides after cycloheximide removal, resulting in a total estimate of 279 proteins induced after vaccinia infection. The glycoproteins made at various time postinfection were also analyzed. At least 13 proteins labeled with [ 3 H]glucosamine were detected in vaccinia-infected HeLa cells

  2. Optimized sample preparation for two-dimensional gel electrophoresis of soluble proteins from chicken bursa of Fabricius

    Directory of Open Access Journals (Sweden)

    Zheng Xiaojuan

    2009-10-01

    Full Text Available Abstract Background Two-dimensional gel electrophoresis (2-DE is a powerful method to study protein expression and function in living organisms and diseases. This technique, however, has not been applied to avian bursa of Fabricius (BF, a central immune organ. Here, optimized 2-DE sample preparation methodologies were constructed for the chicken BF tissue. Using the optimized protocol, we performed further 2-DE analysis on a soluble protein extract from the BF of chickens infected with virulent avibirnavirus. To demonstrate the quality of the extracted proteins, several differentially expressed protein spots selected were cut from 2-DE gels and identified by matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS. Results An extraction buffer containing 7 M urea, 2 M thiourea, 2% (w/v 3-[(3-cholamidopropyl-dimethylammonio]-1-propanesulfonate (CHAPS, 50 mM dithiothreitol (DTT, 0.2% Bio-Lyte 3/10, 1 mM phenylmethylsulfonyl fluoride (PMSF, 20 U/ml Deoxyribonuclease I (DNase I, and 0.25 mg/ml Ribonuclease A (RNase A, combined with sonication and vortex, yielded the best 2-DE data. Relative to non-frozen immobilized pH gradient (IPG strips, frozen IPG strips did not result in significant changes in the 2-DE patterns after isoelectric focusing (IEF. When the optimized protocol was used to analyze the spleen and thymus, as well as avibirnavirus-infected bursa, high quality 2-DE protein expression profiles were obtained. 2-DE maps of BF of chickens infected with virulent avibirnavirus were visibly different and many differentially expressed proteins were found. Conclusion These results showed that method C, in concert extraction buffer IV, was the most favorable for preparing samples for IEF and subsequent protein separation and yielded the best quality 2-DE patterns. The optimized protocol is a useful sample preparation method for comparative proteomics analysis of chicken BF tissues.

  3. In vivo dosimetry in radiation therapy in Sweden; In vivo-dosimetri inom straalbehandling i Sverige

    Energy Technology Data Exchange (ETDEWEB)

    Eriksson, Jacob; Blomquist, Michael (Norrlands universitetssjukhus, Umeaa (Sweden))

    2010-07-15

    A prerequisite for achieving high radiation safety for patients receiving external beam radiation therapy is that the hospitals have a quality assurance program. The program should include include monitoring of the radiation dose given to the patient. Control measurements are performed both at the system level and at the individual level. Control measurement is normally performed using in vivo dosimetry, e.g. a method to measure the radiation dose at the individual level during the actual radiation treatment time. In vivo dosimetry has proven to be an important tool to detect and prevent serious errors in patient treatment. The purpose of this research project was to identify the extent to which vivo dosimetry is used and the methods available for this at Swedish radiation therapy clinics. The authority also wanted to get an overall picture of how hospitals manage results of in vivo dosimetry, and how clinics control radiation dose when using modern treatment techniques. The report reflects the situation in Swedish radiotherapy clinics 2007. The report shows that all hospitals use some form of in vivo dosimetry. The instruments used are mainly diodes and termoluminiscence dosimeters

  4. The Latin American Biological Dosimetry Network (LBDNet).

    Science.gov (United States)

    García, O; Di Giorgio, M; Radl, A; Taja, M R; Sapienza, C E; Deminge, M M; Fernández Rearte, J; Stuck Oliveira, M; Valdivia, P; Lamadrid, A I; González, J E; Romero, I; Mandina, T; Guerrero-Carbajal, C; ArceoMaldonado, C; Cortina Ramírez, G E; Espinoza, M; Martínez-López, W; Di Tomasso, M

    2016-09-01

    Biological Dosimetry is a necessary support for national radiation protection programmes and emergency response schemes. The Latin American Biological Dosimetry Network (LBDNet) was formally founded in 2007 to provide early biological dosimetry assistance in case of radiation emergencies in the Latin American Region. Here are presented the main topics considered in the foundational document of the network, which comprise: mission, partners, concept of operation, including the mechanism to request support for biological dosimetry assistance in the region, and the network capabilities. The process for network activation and the role of the coordinating laboratory during biological dosimetry emergency response is also presented. This information is preceded by historical remarks on biological dosimetry cooperation in Latin America. A summary of the main experimental and practical results already obtained by the LBDNet is also included. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Tangential breast irradiation - rationale and methods for improving dosimetry

    International Nuclear Information System (INIS)

    Neal, A.J.; Mayles, W.P.M.; Yarnold, J.R.

    1994-01-01

    In recent years there have been great advances and innovations in all technical aspects of radiotherapy, including three dimensional (3D) computer planning, patient immobilization, radiation delivery and treatment verification. Despite this progress, the technique of tangential breast irradiation has changed little over this period and has not exploited these advances. There is increasing evidence that dose inhomogeneity within the breast is greater than at other anatomical sites, especially in women with large breasts. This paper is a review of the factors contributing to poor dosimetry in the breast, the clinical consequences of an inhomogeneous dose distribution, and how breast dosimetry could be improved by considering each of the stages from planning to accurate treatment delivery. It also highlights the particular problem of women with large breasts who may be more likely to have a poorer outcome after a fractionated course of radiotherapy than women with small/medium-sized breasts, and supports the clinical impression that such women are also more likely to have greater inhomogenicity when 3D treatment plans are examined. Preliminary data from our current computed tomography (CT) planning study are presented to support these observations. (author)

  6. Research and innovation in radiation dosimetry

    International Nuclear Information System (INIS)

    Delgado, A.

    1999-01-01

    In this article some relevant lines of research in radiation dosimetry are presented. In some of them innovative approaches have been recently proposed in recent years. In others innovation is still to come as it is necessary in view of the insufficiency of the actual methods and techniques. mention is made to Thermoluminescence Dosimetry an to the improvement produced by new computational methods for the analysis of the usually complex TL signals. A solid state dosimetric technique recently proposed, Optically Stimulated Luminescence, OSL, is briefly presented. This technique promises advantages over TLD for personal and environmental dosimetry. The necessity of improving the measurement characteristics of neutron personal dosemeters is commented, making reference to some very recent developments. The situation of the dosimetry in connection with radiobiology research is overviewed, commenting the controversy on the adequacy and utility of the quality absorbed dose for these activities. Finally the special problematic of internal dosimetry is discussed. (Author) 25 refs

  7. Dosimetry control for radiation processing - basic requirements and standards

    International Nuclear Information System (INIS)

    Ivanova, M.; Tsrunchev, Ts.

    2004-01-01

    A brief review of the basic international codes and standards for dosimetry control for radiation processing (high doses dosimetry), setting up a dosimetry control for radiation processing and metrology control of the dosimetry system is made. The present state of dosimetry control for food processing and the Bulgarian long experience in food irradiation (three irradiation facilities are operational at these moment) are presented. The absence of neither national standard for high doses nor accredited laboratory for calibration and audit of radiation processing dosimetry systems is also discussed

  8. Dosimetry in dentistry.

    Science.gov (United States)

    Asha, M L; Chatterjee, Ingita; Patil, Preeti; Naveen, S

    2015-01-01

    The purpose of this paper was to review various dosimeters used in dentistry and the cumulative results of various studies done with various dosimeters. Several relevant PubMed indexed articles from 1999 to 2013 were electronically searched by typing "dosimeters", "dosimeters in dentistry", "properties of dosimeters", "thermoluminescent and optically stimulated dosimeters", "recent advancements in dosimetry in dentistry." The searches were limited to articles in English to prepare a concise review on dental dosimetry. Titles and abstracts were screened, and articles that fulfilled the criteria of use of dosimeters in dental applications were selected for a full-text reading. Article was divided into four groups: (1) Biological effects of radiation, (2) properties of dosimeters, (3) types of dosimeters and (4) results of various studies using different dosimeters. The present review on dosimetry based on various studies done with dosimeters revealed that, with the advent of radiographic technique the effective dose delivered is low. Therefore, selection of radiological technique plays an important role in dental dose delivery.

  9. Water equivalency evaluation of PRESAGE® dosimeters for dosimetry of Cs-137 and Ir-192 brachytherapy sources

    Science.gov (United States)

    Gorjiara, Tina; Hill, Robin; Kuncic, Zdenka; Baldock, Clive

    2010-11-01

    A major challenge in brachytherapy dosimetry is the measurement of steep dose gradients. This can be achieved with a high spatial resolution three dimensional (3D) dosimeter. PRESAGE® is a polyurethane based dosimeter which is suitable for 3D dosimetry. Since an ideal dosimeter is radiologically water equivalent, we have investigated the relative dose response of three different PRESAGE® formulations, two with a lower chloride and bromide content than original one, for Cs-137 and Ir-192 brachytherapy sources. Doses were calculated using the EGSnrc Monte Carlo package. Our results indicate that PRESAGE® dosimeters are suitable for relative dose measurement of Cs-137 and Ir-192 brachytherapy sources and the lower halogen content PRESAGE® dosimeters are more water equivalent than the original formulation.

  10. The importance of 3D dosimetry

    International Nuclear Information System (INIS)

    Low, Daniel

    2015-01-01

    Radiation therapy has been getting progressively more complex for the past 20 years. Early radiation therapy techniques needed only basic dosimetry equipment; motorized water phantoms, ionization chambers, and basic radiographic film techniques. As intensity modulated radiation therapy and image guided therapy came into widespread practice, medical physicists were challenged with developing effective and efficient dose measurement techniques. The complex 3-dimensional (3D) nature of the dose distributions that were being delivered demanded the development of more quantitative and more thorough methods for dose measurement. The quality assurance vendors developed a wide array of multidetector arrays that have been enormously useful for measuring and characterizing dose distributions, and these have been made especially useful with the advent of 3D dose calculation systems based on the array measurements, as well as measurements made using film and portal imagers. Other vendors have been providing 3D calculations based on data from the linear accelerator or the record and verify system, providing thorough evaluation of the dose but lacking quality assurance (QA) of the dose delivery process, including machine calibration. The current state of 3D dosimetry is one of a state of flux. The vendors and professional associations are trying to determine the optimal balance between thorough QA, labor efficiency, and quantitation. This balance will take some time to reach, but a necessary component will be the 3D measurement and independent calculation of delivered radiation therapy dose distributions

  11. The importance of 3D dosimetry

    Science.gov (United States)

    Low, Daniel

    2015-01-01

    Radiation therapy has been getting progressively more complex for the past 20 years. Early radiation therapy techniques needed only basic dosimetry equipment; motorized water phantoms, ionization chambers, and basic radiographic film techniques. As intensity modulated radiation therapy and image guided therapy came into widespread practice, medical physicists were challenged with developing effective and efficient dose measurement techniques. The complex 3-dimensional (3D) nature of the dose distributions that were being delivered demanded the development of more quantitative and more thorough methods for dose measurement. The quality assurance vendors developed a wide array of multidetector arrays that have been enormously useful for measuring and characterizing dose distributions, and these have been made especially useful with the advent of 3D dose calculation systems based on the array measurements, as well as measurements made using film and portal imagers. Other vendors have been providing 3D calculations based on data from the linear accelerator or the record and verify system, providing thorough evaluation of the dose but lacking quality assurance (QA) of the dose delivery process, including machine calibration. The current state of 3D dosimetry is one of a state of flux. The vendors and professional associations are trying to determine the optimal balance between thorough QA, labor efficiency, and quantitation. This balance will take some time to reach, but a necessary component will be the 3D measurement and independent calculation of delivered radiation therapy dose distributions.

  12. Results of the dosimetry intercomparison

    International Nuclear Information System (INIS)

    Dure, Elsa S.

    2000-07-01

    The appropriate way to verify the accuracy of the results of dose reported by the laboratories that offer lend personal dosimetry service is in the periodic participation of round of intercomparison dosimetry, undertaken by laboratories whose standards are trace (Secondary Laboratory). The Laboratory of External Personal Dosimetry of the CNEA-PY has participated in three rounds of intercomparison. The first two were organized in the framework of the Model Project RLA/9/030 RADIOLOGICAL WASTE SECURITY, and the irradiations were carried out in the Laboratory of Regional Calibration of the Center of Nuclear Technology Development, Belo Horizonte-Brazil (1998) and in the National Laboratory of Metrology of the ionizing radiations of the Institute of Radioprotection and Dosimetry, Rio de Janeiro-Brazil (1999). The third was organized by the IAEA and the irradiations were made in the Physikalisch-Technische Bundesanstalt PTB, Braunschweig - Federal Republic of Germany (1999-2000) [es

  13. Process of forming a sol-gel/metal hydride composite

    Science.gov (United States)

    Congdon, James W [Aiken, SC

    2009-03-17

    An external gelation process is described which produces granules of metal hydride particles contained within a sol-gel matrix. The resulting granules are dimensionally stable and are useful for applications such as hydrogen separation and hydrogen purification. An additional coating technique for strengthening the granules is also provided.

  14. Porous alumina scaffold produced by sol-gel combined polymeric sponge method

    Science.gov (United States)

    Hasmaliza, M.; Fazliah, M. N.; Shafinaz, R. J.

    2012-09-01

    Sol gel is a novel method used to produce high purity alumina with nanometric scale. In this study, three-dimensional porous alumina scaffold was produced using sol-gel polymeric sponge method. Briefly, sol gel alumina was prepared by evaporation and polymeric sponge cut to designated sizes were immersed in the sol gel followed by sintering at 1250 and 1550°C. In order to study the cell interaction, the porous alumina scaffold was sterilized using autoclave prior to Human Mesenchymal Stem Cells (HMSCs) seeding on the scaffold and the cell proliferation was assessed by alamarBlue® assay. SEM results showed that during the 21 day period, HMSCs were able to attach on the scaffold surface and the interconnecting pores while maintaining its proliferation. These findings suggested the potential use of the porous alumina produced as a scaffold for implantation procedure.

  15. TCA precipitation and ethanol/HCl single-step purification evaluation: One-dimensional gel electrophoresis, bradford assays, spectrofluorometry and Raman spectroscopy data on HSA, Rnase, lysozyme - Mascots and Skyline data

    Directory of Open Access Journals (Sweden)

    Balkis Eddhif

    2018-04-01

    Full Text Available The data presented here are related to the research paper entitled “Study of a Novel Agent for TCA Precipitated Proteins Washing - Comprehensive Insights into the Role of Ethanol/HCl on Molten Globule State by Multi-Spectroscopic Analyses” (Eddhif et al., submitted for publication [1]. The suitability of ethanol/HCl for the washing of TCA-precipitated proteins was first investigated on standard solution of HSA, cellulase, ribonuclease and lysozyme. Recoveries were assessed by one-dimensional gel electrophoresis, Bradford assays and UPLC-HRMS. The mechanistic that triggers protein conformational changes at each purification stage was then investigated by Raman spectroscopy and spectrofluorometry. Finally, the efficiency of the method was evaluated on three different complex samples (mouse liver, river biofilm, loamy soil surface. Proteins profiling was assessed by gel electrophoresis and by UPLC-HRMS.

  16. Dosimetry standards for radiation processing

    International Nuclear Information System (INIS)

    Farrar, H. IV

    1999-01-01

    For irradiation treatments to be reproducible in the laboratory and then in the commercial environment, and for products to have certified absorbed doses, standardized dosimetry techniques are needed. This need is being satisfied by standards being developed by experts from around the world under the auspices of Subcommittee E10.01 of the American Society for Testing and Materials (ASTM). In the time period since it was formed in 1984, the subcommittee has grown to 150 members from 43 countries, representing a broad cross-section of industry, government and university interests. With cooperation from other international organizations, it has taken the combined part-time effort of all these people more than 13 years to complete 24 dosimetry standards. Four are specifically for food irradiation or agricultural applications, but the majority apply to all forms of gamma, x-ray, Bremsstrahlung and electron beam radiation processing, including dosimetry for sterilization of health care products and the radiation processing of fruits, vegetables, meats, spices, processed foods, plastics, inks, medical wastes and paper. An additional 6 standards are under development. Most of the standards provide exact procedures for using individual dosimetry systems or for characterizing various types of irradiation facilities, but one covers the selection and calibration of dosimetry systems, and another covers the treatment of uncertainties. Together, this set of standards covers essentially all aspects of dosimetry for radiation processing. The first 20 of these standards have been adopted in their present form by the International Organization of Standardization (ISO), and will be published by ISO in 1999. (author)

  17. Individual dosimetry of workers and patients: implementation and perspectives

    International Nuclear Information System (INIS)

    Rannou, A.; Aubert, B.; Lahaye, Th.; Scaff, P.; Casanova, Ph.; Van Bladel, L.; Queinnec, F.; Valendru, N.; Jehanno, J.; Grude, E.; Berard, Ph.; Desbree, A.; Kafrouni, H.; Paquet, F.; Vanhavere, F.; Bridier, A.; Ginestet, Ch.; Magne, S.; Donadille, L.; Bordy, J.M.; Bottollier-Depois, J.F.; Barrere, J.L.; Ferragut, A.; Metivier, H.; Gaillard-Lecanu, E.

    2008-01-01

    These days organised by the section of the technical protection of the S.F.R.P. review the different techniques of dosimetry used in France and Europe, and present the future orientations.The different interventions are as follow: Individual exposures of the workers: historic assessment and perspectives; medical exposure: where are the doses; legal obligations in individual dosimetry: which are the objective and the need on the subject; the dosimetry follow-up of workers by the S.I.S.E.R.I. system: assessment and perspectives; impact of the norm ISO 20553 on the follow-up of internal exposure; the implementation of the patient dose measurement in Belgium; techniques of passive dosimetry used in Europe; Supervision radiation protection at EDF: long term and short term approach; Comparison active and passive dosimetry at Melox; methodology for the choice of new neutron dosemeters; the working group M.E.D.O.R.: guide of internal dosimetry for the use of practitioners; O.E.D.I.P.E.: tool of modeling for the personalized internal dosimetry; the use of the Monte-Carlo method for the planning of the cancer treatment by radiotherapy becomes a reality; the works of the committee 2 of the ICRP; passive dosimetry versus operational dosimetry: situation in Europe; Implementation of the in vivo dosimetry in a radiotherapy department: experience of the Gustave Roussy institute; experience feedback on the in vivo measures in radiotherapy, based on the use of O.S.L. pellets; multi points O.S.L. instrumentation for the radiation dose monitoring in radiotherapy; dosimetry for extremities for medical applications: principle results of the European contract C.O.N.R.A.D.; references and perspectives in dosimetry; what perspectives for numerical dosimetry, an example: Sievert; system of dose management: how to answer to needs; the last technical evolutions in terms of electronic dosimetry in nuclear power plant; the fourth generation type reactors: what dosimetry. (N.C.)

  18. A study on the reproducibility and spatial uniformity of N-isopropylacrylamide polymer gel dosimetry using a commercial 10X fast optical-computed tomography scanner

    International Nuclear Information System (INIS)

    Chang, Y J; Lin, J Q; Hsieh, B T; Chen, C H

    2013-01-01

    This study investigated the reproducibility and spatial uniformity of N-isopropylacrylamide (NIPAM) polymer gel as well as the reproducibility of a NIPAM polymer gel dosimeter. A commercial 10X fast optical computed tomography scanner (OCTOPUS-10X, MGS Research, Inc., Madison, CT, USA) was used as the readout tool of the NIPAM polymer gel dosimeter. A cylindrical NIPAM gel phantom measuring 10 cm (diameter) by 10 cm (height) by 3 mm (thickness) was irradiated by the four-field box treatment with a field size of 3 cm × 3 cm. The dose profiles were found to be consistent at the depths of 2.0 cm to 5.0 cm for two independent gel phantom batches, and the average uncertainty was less than 2%. The gamma pass rates were calculated to be between 94% and 95% at depths of 40 mm for two independent gel phantom batches using 4% dose difference and 4 mm distance-to-agreement criterion. The NIPAM polymer gel dosimeter was highly reproducible and spatially uniform. The results highlighted the potential of the NIPAM polymer gel dosimeter in radiotherapy.

  19. The dosimetry programme of the IAEA

    International Nuclear Information System (INIS)

    1987-01-01

    Describes the activities of the IAEA's Dosimetry Laboratory which provides calibration and comparison services for secondary standard dosimetry laboratories (SSDLs) of Member States. In addition, a joint IAEA/WHO postal dosimetry service has been established for radiotherapy centers. The International Measurement System and the calibration ''chain'' from measurement standard instruments of the International Bureau of Weights and Measurements (BIPM) through the primary and secondary standards to the dosimeters of the users are presented as well

  20. Hematological dosimetry

    International Nuclear Information System (INIS)

    Fluery-Herard, A.

    1991-01-01

    The principles of hematological dosimetry after acute or protracted whole-body irradiation are reviewed. In both cases, over-exposure is never homogeneous and the clinical consequences, viz medullary aplasia, are directly associated with the mean absorbed dose and the seriousness and location of the overexposure. The main hematological data required to assess the seriousness of exposure are the following: repeated blood analysis, blood precursor cultures, as indicators of whole-body exposure; bone marrow puncture, medullary precursor cultures and medullary scintigraphy as indicators of the importance of a local over-exposure and capacity for spontaneous repair. These paraclinical investigations, which are essential for diagnosis and dosimetry, are also used for surveillance and for the main therapeutic issues [fr

  1. Development and current state of dosimetry in Cuba

    International Nuclear Information System (INIS)

    Prieto Miranda, E.F.; Cuesta Fuente, G.; Chavez Ardanza, A.

    1999-01-01

    In Cuba, the application of the radiation technologies has been growing in the last years, and at present there are several dosimetry systems with different ranges of absorbed dose. Diverse researches were carried out on high dose dosimetry with the following dosimetry systems: Fricke, ceric-cerous sulfate, ethanol-chlorobenzene, cupric sulfate and Perspex (Red 4034 AE and Clear HX). In this paper the development achieved during the last 15 years in the high dose dosimetry for radiation processing in Cuba is presented, as well as, the current state of different dosimetry systems employed for standardization and for process control. The paper also reports the results of dosimetry intercomparison studies that were performed with the Ezeiza Atomic Center of Argentine and the International Dose Assurance Service (IDAS) of IAEA. (author)

  2. Two-dimensional gel electrophoresis data in support of leaf comparative proteomics of two citrus species differing in boron-tolerance

    Directory of Open Access Journals (Sweden)

    Wen Sang

    2015-09-01

    Full Text Available Here, we provide the data from a comparative proteomics approach used to investigate the response of boron (B-tolerant ‘Xuegan’ (Citrus sinensis and B-intolerant ‘Sour pummelo’ (Citrus grandis leaves to B-toxicity. Using two-dimensional gel electrophoresis (2-DE technique, we identified 50 and 45 protein species with a fold change of more than 1.5 and a P-value of less than 0.05 from B-toxic C. sinensis and C. grandis leaves. These B-toxicity-responsive protein species were mainly involved in carbohydrate and energy metabolism, antioxidation and detoxification, stress responses, coenzyme biosynthesis, protein and amino acid metabolism, signal transduction, cell transport, cytoskeleton, nucleotide metabolism, and cell cycle and DNA processing. A detailed analysis of this data may be obtained from Sang et al. (J. Proteomics 114 (2015[1].

  3. Miniature semiconductor detectors for in vivo dosimetry

    International Nuclear Information System (INIS)

    Rosenfeld, A. B.; Cutajar, D.; Lerch, M. L. F.; Takacs, G.; Cornelius, I. M.; Yudelev, M.; Zaider, M.

    2006-01-01

    Silicon mini-semiconductor detectors are found in wide applications for in vivo personal dosimetry and dosimetry and Micro-dosimetry of different radiation oncology modalities. These applications are based on integral and spectroscopy modes of metal oxide semiconductor field effect transistor and silicon p-n junction detectors. The advantages and limitations of each are discussed. (authors)

  4. Three-Dimensional Nanoporous Cellulose Gels as a Flexible Reinforcement Matrix for Polymer Nanocomposites.

    Science.gov (United States)

    Shi, Zhuqun; Huang, Junchao; Liu, Chuanjun; Ding, Beibei; Kuga, Shigenori; Cai, Jie; Zhang, Lina

    2015-10-21

    With the world's focus on utilization of sustainable natural resources, the conversion of wood and plant fibers into cellulose nanowhiskers/nanofibers is essential for application of cellulose in polymer nanocomposites. Here, we present a novel fabrication method of polymer nanocomposites by in-situ polymerization of monomers in three-dimensionally nanoporous cellulose gels (NCG) prepared from aqueous alkali hydroxide/urea solution. The NCG have interconnected nanofibrillar cellulose network structure, resulting in high mechanical strength and size stability. Polymerization of the monomer gave P(MMA/BMA)/NCG, P(MMA/BA)/NCG nanocomposites with a volume fraction of NCG ranging from 15% to 78%. SEM, TEM, and XRD analyses show that the NCG are finely distributed and preserved well in the nanocomposites after polymerization. DMA analysis demonstrates a significant improvement in tensile storage modulus E' above the glass transition temperature; for instance, at 95 °C, E' is increased by over 4 orders of magnitude from 0.03 MPa of the P(MMA/BMA) up to 350 MPa of nanocomposites containing 15% v/v NCG. This reinforcement effect can be explained by the percolation model. The nanocomposites also show remarkable improvement in solvent resistance (swelling ratio of 1.3-2.2 in chloroform, acetone, and toluene), thermal stability (do not melt or decompose up to 300 °C), and low coefficients of thermal expansion (in-plane CTE of 15 ppm·K(-1)). These nanocomposites will have great promising applications in flexible display, packing, biomedical implants, and many others.

  5. Measurements of the Fe3+ diffusion coefficient in Fricke Xylenol gel using optical density measurements

    International Nuclear Information System (INIS)

    Nonato de Oliveira, Lucas; Sampaio, Francisco Glaildo Almeida; Moreira, Marcos Vasques; Almeida, Adelaide de

    2014-01-01

    In Fricke dosimetry, optical density measurements are performed some time after dosimeter irradiation. Values of the diffusion coefficient of Fe 3+ in Fricke Xylenol gel (FXG) are necessary for determining the spatial distribution of the absorbed dose from measurements of the optical density. Five sets of FXG dosimeters, kept at different constant temperatures, were exposed to collimated 6 MV photons. The optical density profile, proportional to the Fe 3+ concentration, at the boundary between irradiated and non-irradiated parts of each dosimeter was measured periodically over a period of 60 h. By comparing the experimental data with a function that accounts for the unobserved initial concentration profile of Fe 3+ in the FXG, we obtained diffusion coefficients 0.30±0.05, 0.40±0.05, 0.50±0.05, 0.60±0.05 and 0.80±0.05 mm 2 /h for the temperatures 283.0±0.5, 286.0±0.5, 289.0±0.5, 292.0±0.5, and 296.0±0.5 K, respectively. The activation energy of Fe 3+ diffusion in the gel, 0.54±0.06 eV, was determined from the temperature dependence of the diffusion coefficients. - Highlights: • A new analytical method to determine diffusion coefficients of ions in gels is proposed. • The method is applied for measurements of the diffusion coefficients of Fe 3+ ions in a Fricke gel dosimeter. • Activation energy of the Fe 3+ ions in the gel was found to be 0.54 ±0.06 eV

  6. In-situ radiation dosimetry based on radio-fluorogenic co-polymerization

    International Nuclear Information System (INIS)

    Warman, John M; Luthjens, Leonard H; Haas, Matthijs P de

    2009-01-01

    A fluorimetric method of radiation dosimetry is presented for which the intensity of the fluorescence of a (tissue equivalent) medium is linearly dependent on accumulated dose from a few Gray up to kiloGrays. The method is based on radio-fluorogenic co-polymerization (RFCP) in which a normally very weakly fluorescent molecule becomes highly fluorescent when incorporated into a (radiation-initiated) growing polymer chain. The method is illustrated with results of in-situ measurements within the chamber of a cobalt-60 irradiator. It is proposed that RFCP could form the basis for fluorimetric multi-dimensional dose imaging.

  7. Chemical dosimetry system for criticality accidents.

    Science.gov (United States)

    Miljanić, Saveta; Ilijas, Boris

    2004-01-01

    Ruder Bosković Institute (RBI) criticality dosimetry system consists of a chemical dosimetry system for measuring the total (neutron + gamma) dose, and a thermoluminescent (TL) dosimetry system for a separate determination of the gamma ray component. The use of the chemical dosemeter solution chlorobenzene-ethanol-trimethylpentane (CET) is based on the radiolytic formation of hydrochloric acid, which protonates a pH indicator, thymolsulphonphthalein. The high molar absorptivity of its red form at 552 nm is responsible for a high sensitivity of the system: doses in the range 0.2-15 Gy can be measured. The dosemeter has been designed as a glass ampoule filled with the CET solution and inserted into a pen-shaped plastic holder. For dose determinations, a newly constructed optoelectronic reader has been used. The RBI team took part in the International Intercomparison of Criticality Accident Dosimetry Systems at the SILENE Reactor, Valduc, June 2002, with the CET dosimetry system. For gamma ray dose determination TLD-700 TL detectors were used. The results obtained with CET dosemeter show very good agreement with the reference values.

  8. Dosimetry as an integral part of radiation processing

    International Nuclear Information System (INIS)

    Zagorski, Z.P.

    1999-01-01

    Different connections between high-dose dosimetry and radiation processing are discussed. Radiation processing cannot be performed without proper dosimetry. Accurate high dose and high dose rate dosimetry exhibits several aspects: first of all it is the preservation of the quality of the product, then fulfillment of legal aspects and last but not the least the safety of processing. Further, seldom discussed topics are as follow: dosimetric problems occurring with double-side EB irradiations, discussed in connection with the deposition of electric charge during electron beam irradiation. Although dosimetry for basic research and for medical purposes are treated here only shortly, some conclusions reached from these fields are considered in dosimetry for radiation processing. High-dose dosimetry of radiation has become a separate field, with many papers published every year, but applied dosimetric projects are usually initiated by a necessity of particular application. (author)

  9. Implementation of IMRT and VMAT using Delta4 phantom and portal dosimetry as dosimetry verification tools

    Energy Technology Data Exchange (ETDEWEB)

    Daci, Lulzime, E-mail: lulzime.daci@nodlandssykehuset.no [Nordland Hospital Trust, Bodø (Norway); Malkaj, Partizan, E-mail: malkaj-p@hotmail.com [Faculty of Mathematics Engineering and Physics Engineering, Polytechnic University of Tirana (Albania)

    2016-03-25

    In this study we analyzed and compared the dose distribution of different IMRT and VMAT plans with the intent to provide pre-treatment quality assurance using two different tools. Materials/Methods: We have used the electronic portal imaging device EPID after calibration to dose and correction for the background offset signal and also the Delta4 phantom after en evaluation of angular sensitivity. The Delta4 phantom has a two-dimensional array with ionization chambers. We analyzed three plans for each anatomical site calculated by Eclipse treatment planning system. The measurements were analyzed using γ-evaluation method with passing criteria 3% absolute dose and 3 mm distance to agreement (DTA). For all the plans the range of score has been from 97% to 99% for gantry fixed at 0° while for rotational planes there was a slightly decreased pass rates and above 95%. Point measurement with a ionization chamber were done in additional to see the accuracy of portal dosimetry and to evaluate the Delta4 device to various dose rates. Conclusions: Both Delt4 and Portal dosimetry shows good results between the measured and calculated doses. While Delta4 is more accurate in measurements EPID is more time efficient. We have decided to use both methods in the first steps of IMRT and VMAT implementation and later on to decide which of the tools to use depending on the complexity of plans, how much accurate we want to be and the time we have on the machine.

  10. Implementation of IMRT and VMAT using Delta4 phantom and portal dosimetry as dosimetry verification tools

    International Nuclear Information System (INIS)

    Daci, Lulzime; Malkaj, Partizan

    2016-01-01

    In this study we analyzed and compared the dose distribution of different IMRT and VMAT plans with the intent to provide pre-treatment quality assurance using two different tools. Materials/Methods: We have used the electronic portal imaging device EPID after calibration to dose and correction for the background offset signal and also the Delta4 phantom after en evaluation of angular sensitivity. The Delta4 phantom has a two-dimensional array with ionization chambers. We analyzed three plans for each anatomical site calculated by Eclipse treatment planning system. The measurements were analyzed using γ-evaluation method with passing criteria 3% absolute dose and 3 mm distance to agreement (DTA). For all the plans the range of score has been from 97% to 99% for gantry fixed at 0° while for rotational planes there was a slightly decreased pass rates and above 95%. Point measurement with a ionization chamber were done in additional to see the accuracy of portal dosimetry and to evaluate the Delta4 device to various dose rates. Conclusions: Both Delt4 and Portal dosimetry shows good results between the measured and calculated doses. While Delta4 is more accurate in measurements EPID is more time efficient. We have decided to use both methods in the first steps of IMRT and VMAT implementation and later on to decide which of the tools to use depending on the complexity of plans, how much accurate we want to be and the time we have on the machine.

  11. The work programme of EURADOS on internal and external dosimetry.

    Science.gov (United States)

    Rühm, W; Bottollier-Depois, J F; Gilvin, P; Harrison, R; Knežević, Ž; Lopez, M A; Tanner, R; Vargas, A; Woda, C

    2018-01-01

    Since the early 1980s, the European Radiation Dosimetry Group (EURADOS) has been maintaining a network of institutions interested in the dosimetry of ionising radiation. As of 2017, this network includes more than 70 institutions (research centres, dosimetry services, university institutes, etc.), and the EURADOS database lists more than 500 scientists who contribute to the EURADOS mission, which is to promote research and technical development in dosimetry and its implementation into practice, and to contribute to harmonisation of dosimetry in Europe and its conformance with international practices. The EURADOS working programme is organised into eight working groups dealing with environmental, computational, internal, and retrospective dosimetry; dosimetry in medical imaging; dosimetry in radiotherapy; dosimetry in high-energy radiation fields; and harmonisation of individual monitoring. Results are published as freely available EURADOS reports and in the peer-reviewed scientific literature. Moreover, EURADOS organises winter schools and training courses on various aspects relevant for radiation dosimetry, and formulates the strategic research needs in dosimetry important for Europe. This paper gives an overview on the most important EURADOS activities. More details can be found at www.eurados.org .

  12. User`s guide and documentation manual for ``PC-Gel`` simulator

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Ming-Ming; Gao, Hong W.

    1993-10-01

    PC-GEL is a three-dimensional, three-phase (oil, water, and gas) permeability modification simulator developed by incorporating an in-situ gelation model into a black oil simulator (BOAST) for personal computer application. The features included in the simulator are: transport of each chemical species of the polymer/crosslinker system in porous media, gelation reaction kinetics of the polymer with crosslinking agents, rheology of the polymer and gel, inaccessible pore volume to macromolecules, adsorption of chemical species on rock surfaces, retention of gel on the rock matrix, and permeability reduction caused by the adsorption of polymer and gel. The in-situ gelation model and simulator were validated against data reported in the literature. The simulator PC-GEL is useful for simulating and optimizing any combination of primary production, waterflooding, polymer flooding, and permeability modification treatments. A general background of permeability modification using crosslinked polymer gels is given in Section I and the governing equations, mechanisms, and numerical solutions of PC-GEL are given in Section II. Steps for preparing an input data file with reservoir and gel-chemical transport data, and recurrent data are described in Sections III and IV, respectively. Example data inputs are enclosed after explanations of each input line to help the user prepare data files. Major items of the output files are reviewed in Section V. Finally, three sample problems for running PC-GEL are described in Section VI, and input files and part of the output files of these problems are listed in the appendices. For the user`s reference a copy of the source code of PC-GEL computer program is attached in Appendix A.

  13. Dosimetry and operation of irradiation facilities

    International Nuclear Information System (INIS)

    Vidal, P.E.

    1985-01-01

    The industrial use of ionizing radiation has required, from the very first, the measurement of delivered and absorbed doses; hence the necessity of providing dosimetric systems. Laboratories, scientists, industries and potential equipment manufacturers have all collaborated in this new field of activity. Dosimetric intercomparisons have been made by each industry at their own facilities and in collaboration with specialists, national organizations and the IAEA. Dosimetry has become a way of ensuring that treatment by irradiation has been carried out in accordance with the rules. It has become in effect assurance of quality. Routine dosimetry should determine a maximum and minimum dose. Numerous factors play a part in dosimetry. Industry is currently in possession of routine dosimetric systems that are sufficiently accurate, fairly easy to handle and reasonable in cost, thereby satisfying all the requirements of industry and the need for control. Dosimetry is important in the process of marketing irradiated products. The operator of an industrial irradiation facility bases his dosimetry on comparison with reference systems. Research aimed at simplifying the practice of routine dosimetry should be continued. New physical and chemical techniques will be incorporated into systems already in use. The introduction of microcomputers into the operation of radiation facilities has increased the value of dosimetry and made the conditions of treatment more widespread. Stress should be placed on research in several areas apart from reference systems, for example: dosimetric systems at temperatures from +8 deg. C to -45 deg. C, over the dose range 100 krad to a little more than 1 Mrad, liquids and fluidized solids carried at high speed through ducts, thin-film liquids circulating at a high flow rate, and various other problems. (author)

  14. Foundations of ionizing radiation dosimetry

    International Nuclear Information System (INIS)

    Denisenko, O.N.; Pereslegin, I.A.

    1985-01-01

    Foundations of dosimetry in application to radiotherapy are presented. General characteristics of ionizing radiations and main characteristics of ionizing radiation sources, mostly used in radiotherapy, are given. Values and units for measuring ionizing radiation (activity of a radioactive substance, absorbed dose, exposure dose, integral dose and dose equivalent are considered. Different methods and instruments for ionizing radiation dosimetry are discussed. The attention is paid to the foundations of clinical dosimetry (representation of anatomo-topographic information, choice of radiation conditions, realization of radiation methods, corrections for a configuration and inhomogeneity of a patient's body, account of biological factors of radiation effects, instruments of dose field formation, control of irradiation procedure chosen)

  15. Stimuli-Triggered Sol-Gel Transitions of Polypeptides Derived from α-Amino Acid N-Carboxyanhydride (NCA) Polymerizations.

    Science.gov (United States)

    He, Xun; Fan, Jingwei; Wooley, Karen L

    2016-02-18

    The past decade has witnessed significantly increased interest in the development of smart polypeptide-based organo- and hydrogel systems with stimuli responsiveness, especially those that exhibit sol-gel phase-transition properties, with an anticipation of their utility in the construction of adaptive materials, sensor designs, and controlled release systems, among other applications. Such developments have been facilitated by dramatic progress in controlled polymerizations of α-amino acid N-carboxyanhydrides (NCAs), together with advanced orthogonal functionalization techniques, which have enabled economical and practical syntheses of well-defined polypeptides and peptide hybrid polymeric materials. One-dimensional stacking of polypeptides or peptide aggregations in the forms of certain ordered conformations, such as α helices and β sheets, in combination with further physical or chemical cross-linking, result in the construction of three-dimensional matrices of polypeptide gel systems. The macroscopic sol-gel transitions, resulting from the construction or deconstruction of gel networks and the conformational changes between secondary structures, can be triggered by external stimuli, including environmental factors, electromagnetic fields, and (bio)chemical species. Herein, the most recent advances in polypeptide gel systems are described, covering synthetic strategies, gelation mechanisms, and stimuli-triggered sol-gel transitions, with the aim of demonstrating the relationships between chemical compositions, supramolecular structures, and responsive properties of polypeptide-based organo- and hydrogels. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Thermoluminescence in medical dosimetry; Termoluminiscencia en dosimetria medica

    Energy Technology Data Exchange (ETDEWEB)

    Rivera, T., E-mail: trivera@ipn.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico)

    2011-10-15

    The dosimetry by thermoluminescence (Tl) is applied in the entire world for the dosimetry of ionizing radiations specially to personal and medical dosimetry. This dosimetry method has been very interesting for measures in vivo because the Tl dosimeters have the advantage of being very sensitive in a very small volume and they are also equivalent to tissue and they do not need additional accessories (for example, cable, electrometer, etc.) The main characteristics of the diverse Tl materials to be used in the radiation measures and practical applications are: the Tl curve, the share homogeneity, the signal stability after the irradiation, precision and exactitude, the response in function with the dose and the energy influence. In this work a brief summary of the advances of the radiations dosimetry is presented by means of the thermally stimulated luminescence and its application to the dosimetry in radiotherapy. (Author)

  17. Conformal three dimensional radiotherapy treatment planning in Lund

    International Nuclear Information System (INIS)

    Knoos, T.; Nilsson, P.; Anders, A.

    1995-01-01

    The use of conformal therapy is based on 3-dimensional treatment planning as well as on methods and routines for 3-dimensional patient mapping, 3-dimensional virtual simulation and others. The management of patients at the Radiotherapy Department at the University Hospital in Lund (Sweden) is discussed. About 2100 new patients are annually treated with external radiotherapy using seven linear accelerators. Three of the accelerators have dual photon energies and electron treatment facilities. A multi-leaf collimator as well as an electronic portal imaging device are available on one machine. Two simulators and an in-house CT-scanner are used for treatment planning. From 1988 to 1992 Scandiplan (Umplan) was used. Since 1992, the treatment planning system is TMS (HELAX AB, Sweden), which is based on the pencil beam algorithm of Ahnesjo. The calculations use patient modulated accelerator specific energy fluence spectra which are compiled with pencil beams from Monte Carlo generated energy absorption kernels. Heterogeneity corrections are performed with results close to conventional algorithms. Irregular fields, either from standard or individual blocks and from multi-leaf collimators are handled by the treatment planning system. The field shape is determined conveniently using the beam's eye view. The final field shape is exported electronically to either the block cutting machine or the multileaf collimator control computer. All patient fields are checked against the beam's eye view during simulation using manual methods. Treatment verification is performed by portal films and in vivo dosimetry with silicon diodes or TL-dosimetry. Up to now, approximately 4400 patients have received a highly individualized 3-dimensional conformal treatment

  18. SU-F-T-434: Development of a Fan-Beam Optical Scanner Using CMOS Array for Small Field Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Brost, E; Warmington, L; Watanabe, Y [Department of Radiation Oncology, University of Minnesota, Minneapolis, MN (United States); Senthilkumar, S [Department of Physics, Vel Tech University, Chennai (India); Departamento de Ingeneria Fisica, DCI, Universidad de Guanajuato, Campus Leon, Guanajuato (Mexico)

    2016-06-15

    Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The sample stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.

  19. SU-F-T-434: Development of a Fan-Beam Optical Scanner Using CMOS Array for Small Field Dosimetry

    International Nuclear Information System (INIS)

    Brost, E; Warmington, L; Watanabe, Y; Senthilkumar, S

    2016-01-01

    Purpose: To design and construct a second generation optical computed tomography (OCT) system using a fan-beam with a CMOS array detector for the 3D dosimetry with polymer gel and radiochromic solid dosimeters. The system was specifically designed for the small field dosimetry. Methods: The optical scanner used a fan-beam laser, which was produced from a collimated red laser beam (λ=620 nm) with a 15-degree laser-line generating lens. The fan-beam was sent through an index-matching bath which holds the sample stage and a sample. The emerging laser light was detected with a 2.54 cm-long CMOS array detector (512 elements). The sample stage rotated through the full 360 degree projection angles at 0.9-degree increments. Each projection was normalized to the unirradiated sample at the projection angle to correct for imperfections in the dosimeter. A larger sample could be scanned by using a motorized mirror and linearly translating the CMOS detector. The height of the sample stage was varied for a full 3D scanning. The image acquisition and motor motion was controlled by a computer. The 3D image reconstruction was accomplished by a fan-beam reconstruction algorithm. All the software was developed inhouse with MATLAB. Results: The scanner was used on both PRESAGE and PAGAT gel dosimeters. Irreconcilable refraction errors were seen with PAGAT because the fan beam laser line refracted away from the detector when the field was highly varying in 3D. With PRESAGE, this type of error was not seen. Conclusion: We could acquire tomographic images of dose distributions by the new OCT system with both polymer gel and radiochromic solid dosimeters. Preliminary results showed that the system was more suited for radiochromic solid dosimeters since the radiochromic dosimeters exhibited minimal refraction and scattering errors. We are currently working on improving the image quality by thorough characterization of the OCT system.

  20. Performing personnel dosimetry investigations and records quality assurance

    International Nuclear Information System (INIS)

    Perle, S.C.

    2002-01-01

    Radiation Safety Officers (RSOs) sometimes face situations in which personnel dosimetry estimates are required after dosimeters issued to radiation workers (film or TLD badges, extremity dosimeters, etc.) are lost or damaged before processing. This article was prepared to help those involved with personnel dosimetry investigations became aquatinted with this process. A factor that contributes to the anxiety of those unfamiliar with dosimetry investigations is the lack of published guidance available in this subject. More printed resources are needed to help radiation safety professionals familiarize themselves and understand personnel dosimetry investigations. Topics discussed in this presentation include the justification of performing dosimetry investigations, recommendations on how to perform them and the advantages of performing such investigations

  1. Dosimetry and Shielding of X and Gamma Radiation

    International Nuclear Information System (INIS)

    Oncescu, M.; Panaitescu, I.

    1992-01-01

    This book covers the following problems: 1. X and Gamma radiations, 2. Interaction of X-ray and gamma radiations with matter, 3. Interaction of electrons with matter, 4. Principles and basic concepts of dosimetry, 5. Ionization dosimetry, 6. Calorimetric chemical and photographic dosimetry, 7. Solid state dosimetry, 8. Computation of dosimetric quantities, 9. Dosimetry in radiation protection, 10. Shielding of X and gamma radiations. The authors, well-known Romanian experts in Radiation Physics and Engineering, gave an up-dated, complete and readable account of this subject matter. The analyses of physical principles and concepts, of materials and instruments and of computational methods and applications are all well balanced to meat the needs of a broad readership

  2. Radiotherapy Based On α Emitting Radionuclides: Geant4 For Dosimetry And Micro-/Nano-Dosimetry

    International Nuclear Information System (INIS)

    Guatelli, Susanna

    2013-01-01

    Possible physics approaches to evaluate the efficacy of TAT are dosimetry, microdosimetry and nanodosimetry. Dosimetry is adequate when mean absorbed dose to a macroscopic target volume is important to understand the biological effect of radiation. General purpose Monte Carlo (MC) codes, based on condensed history approach, are a very useful, cost effective tool to solve dosimetric problems. The condensed history approach is based on the use of multiple scattering theories to calculate the energy losses and angular changes in the direction of the particle. The short α particle range and high LET make the microdosimetric approach more suitable than dosimetry to study TAT from first physics principles, as this approach takes into account the stochastic nature of energy deposition at cellular level

  3. Updating the INDAC computer application of internal dosimetry

    International Nuclear Information System (INIS)

    Bravo Perez-Tinao, B.; Marchena Gonzalez, P.; Sollet Sanudo, E.; Serrano Calvo, E.

    2013-01-01

    The initial objective of this project is to expand the application INDAC currently used in internal dosimetry services of the Spanish nuclear power plants and Tecnatom for estimating the effective doses of internal dosimetry of workers in direct action. or in-vivo dosimetry. (Author)

  4. Dosimetry methods

    DEFF Research Database (Denmark)

    McLaughlin, W.L.; Miller, A.; Kovacs, A.

    2003-01-01

    Chemical and physical radiation dosimetry methods, used for the measurement of absorbed dose mainly during the practical use of ionizing radiation, are discussed with respect to their characteristics and fields of application....

  5. Study of film dosimetry for radiotherapy with Gafchromic-RTQ plates

    International Nuclear Information System (INIS)

    Diaz Moreno, Rogelio Manuel; Lara Mas, Elier; Alfonso Laguardia, Rodolfo

    2009-01-01

    Film dosimetry allows quality control processes (CC) for advanced radiotherapy treatments, not achievable with other types of systems dosimetry, as is the determination of two-dimensional dose distribution provided with the planned treatment in selected planes. The aim of this work was to establish the possibilities of making this type of CC with the means available in the INOR. Plates were used radiochromic Gafchromic-RTQ, for quality control, which irradiated with Elekta Precise linear accelerator, according to the test planning developed in the treatment planning system Precise Plan. Were used as image processing software the Mephysto mc2, PTW, and routines scheduled at home on Matlab. Was prepared calibration curve Dose-response for these plates, and applied this calibration curve at other boards with known radiation dose to estimate proximity of the dose obtained through calibration. Other tests were performed to determine the conditions of repeatability and optimal parameters of the process. Conditions were established that are obtained more reliable , the which are lower than those reported Gafchromic-EBT plates, especially designed quantitative dosimetric purposes, but in certain ranges allow evaluate the of a plan with an acceptable degree of approximation. (author)

  6. Preliminary study of diffusion effects in Fricke gel dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Quiroga, A. [Centro de Investigacion y Estudios de Matematica de Cordoba, Oficina 318 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina); Vedelago, J. [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina); Valente, M., E-mail: aiquiroga@famaf.unc.edu [Instituto de Fisica Enrique Gaviola, Oficina 102 FaMAF - UNC, Av. Luis Medina Allende, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    in standard dependence of optical density differences and actual, non-diffused, absorbed dose distributions. The obtained values for ferric ion diffusion coefficient, in mm{sup 2} h{sup -1} were (1.24 ± 0.07) and (1.15 ± 0.05) for the 1D and 2D method, respectively, in the first approach method and (0.65 ± 0.01), (0.68 ± 0.02) and (0.65 ± 0.02) in the second approach method. The results show good agreement with previous works corresponding to similar Fricke gel dosimeter compositions. Thus, more accurate 2D and 3D dose mapping might be attained that constitutes valuable improvements in Fricke gel dosimetry, and parallel a high precision methods of diffusion model and calculation have been developed. (Author)

  7. Radiation dosimetry in nuclear medicine

    International Nuclear Information System (INIS)

    Stabin, M.G.; Tagesson, M.; Ljungberg, M.; Strand, S.E.; Thomas, S.R.

    1999-01-01

    Radionuclides are used in nuclear medicine in a variety of diagnostic and therapeutic procedures. A knowledge of the radiation dose received by different organs in the body is essential to an evaluation of the risks and benefits of any procedure. In this paper, current methods for internal dosimetry are reviewed, as they are applied in nuclear medicine. Particularly, the Medical Internal Radiation Dose (MIRD) system for dosimetry is explained, and many of its published resources discussed. Available models representing individuals of different age and gender, including those representing the pregnant woman are described; current trends in establishing models for individual patients are also evaluated. The proper design of kinetic studies for establishing radiation doses for radiopharmaceuticals is discussed. An overview of how to use information obtained in a dosimetry study, including that of the effective dose equivalent (ICRP 30) and effective dose (ICRP 60), is given. Current trends and issues in internal dosimetry, including the calculation of patient-specific doses and in the use of small scale and microdosimetry techniques, are also reviewed

  8. An IAEA Survey of Dosimetry Audit Networks for Radiotherapy

    International Nuclear Information System (INIS)

    Grochowska, Paulina; Izewska, Joanna

    2013-01-01

    A Survey: In 2010, the IAEA undertook a task to investigate and review the coverage and operations of national and international dosimetry audit programmes for radiotherapy. The aim was to organize the global database describing the activities of dosimetry audit networks in radiotherapy. A dosimetry audit questionnaire has been designed at an IAEA consultants' meeting held in 2010 for organizations conducting various levels of dosimetry audits for radiotherapy. Using this questionnaire, a survey was conducted for the first time in 2010 and repeated in 2011. Request for information on different aspects of the dosimetry audit was included, such as the audit framework and resources, its coverage and scope, the dosimetry system used and the modes of audit operation, i.e. remotely and through on-site visits. The IAEA questionnaire was sent to over 80 organizations, members of the IAEA/WHO Network of Secondary Standards Dosimetry Laboratories (SSDLs) and other organizations known for having operated dosimetry audits for radiotherapy in their countries or internationally. Survey results and discussion: In response to the IAEA survey, 53 organizations in 45 countries confirmed that they operate dosimetry audit services for radiotherapy. Mostly, audits are conducted nationally, however there are five organizations offering audits abroad, with two of them operating in various parts of the world and three of them at the regional level, auditing radiotherapy centres in neighbouring countries. The distribution of dosimetry audit services in the world is given. (author)

  9. Personnel neutron dosimetry at Department of Energy facilities

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; Endres, G.W.R.; Selby, J.M.; Vallario, E.J.

    1980-08-01

    This study assesses the state of personnel neutron dosimetry at DOE facilities. A survey of the personnel dosimetry systems in use at major DOE facilities was conducted, a literature search was made to determine recent advances in neutron dosimetry, and several dosimetry experts were interviewed. It was concluded that personnel neutron dosimeters do not meet current needs and that serious problems exist now and will increase in the future if neutron quality factors are increased and/or dose limits are lowered

  10. Rationale, design and methods of the ESPRIT study: Energy, Sexual desire and body PropoRtions wIth AndroGel, Testosterone 1% gel therapy, in hypogonadal men.

    Science.gov (United States)

    Behre, Hermann M; Heinemann, Lothar; Morales, Alvaro; Pexman-Fieth, Claire

    2008-06-01

    Hypogonadism is associated with a range of disease states that have significant effects on morbidity and mortality, and also affect quality of life. The ESPRIT study (Energy, Sexual desire and body PropoRtions wIth AndroGel, Testosterone 1% gel therapy) is a 6-month, multinational, open label, observational study in hypogonadal men being treated with transdermal AndroGel in usual daily clinical practice; 1,700-2,400 patients will be enrolled in Canada, Germany, Central and Eastern Europe, Russia and the Middle East. The main objective will be to evaluate the effect of AndroGel on symptoms of hypogonadism and quality of life as assessed by the Aging Males' Symptoms scale. Further objectives include evaluating the effect and time to onset of improvement in erectile dysfunction and libido/sexual desire (International Index of Erectile Function), fatigue (Multi-dimensional Fatigue Index) and body composition (waist circumference, body mass index). Subgroup analyses will be performed: or = 50 years; absence versus presence of metabolic syndrome. The safety of AndroGel will also be assessed. The study population will consist of newly diagnosed hypogonadal men (age > or = 18 years), in whom testosterone deficiency has been confirmed by clinical features and biochemical tests according to international guidelines, who are currently being prescribed AndroGel (testosterone 1% gel, starting dose 50 mg testosterone per day).

  11. Internal dosimetry hazard and risk assessments: methods and applications

    International Nuclear Information System (INIS)

    Roberts, G.A.

    2006-01-01

    Routine internal dose exposures are typically (in the UK nuclear industry) less than external dose exposures: however, the costs of internal dosimetry monitoring programmes can be significantly greater than those for external dosimetry. For this reason decisions on when to apply routine monitoring programmes, and the nature of these programmes, can be more critical than for external dosimetry programmes. This paper describes various methods for performing hazard and risk assessments which are being developed by RWE NUKEM Limited Approved Dosimetry Services to provide an indication when routine internal dosimetry monitoring should be considered. (author)

  12. Radiation protection dosimetry in medicine - Report of the working group n.9 of the European radiation dosimetry group (EURADOS) - coordinated network for radiation dosimetry (CONRAD - contract EC N) fp6-12684; Dosimetrie pour la radioprotection en milieu medical - rapport du groupe de travail n. 9 du European radiation dosimetry group (EURADOS) - coordinated netword for radiation dosimetry (CONRAD - contrat CE fp6-12684)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    This report present the results achieved within the frame of the work the WP 7 (Radiation Protection Dosimetry of Medical Staff) of the coordination action CONRAD (Coordinated Network for Radiation Dosimetry) funded through the 6. EU Framework Program. This action was coordinated by EURADOS (European Radiation Dosimetry Group). EURADOS is an organization founded in 1981 to advance the scientific understanding and the technical development of the dosimetry of ionising radiation in the fields of radiation protection, radiobiology, radiation therapy and medical diagnosis by promoting collaboration between European laboratories. WP7 coordinates and promotes European research for the assessment of occupational exposures to staff in therapeutic and diagnostic radiology workplaces. Research is coordinated through sub-groups covering three specific areas: 1. Extremity dosimetry in nuclear medicine and interventional radiology: this sub-group coordinates investigations in the specific fields of the hospitals and studies of doses to different parts of the hands, arms, legs and feet; 2. Practice of double dosimetry: this sub-group reviews and evaluates the different methods and algorithms for the use of dosemeters placed above and below lead aprons in large exposure during interventional radiology procedures, especially to determine effective doses to cardiologists during cardiac catheterization; and 3. Use of electronic personal dosemeters in interventional radiology: this sub-group coordinates investigations in laboratories and hospitals, and intercomparisons with passive dosemeters with the aim to enable the formulation of standards. (authors)

  13. Neutron personnel dosimetry considerations for fusion reactors

    International Nuclear Information System (INIS)

    Barton, T.P.; Easterly, C.E.

    1979-07-01

    The increasing development of fusion reactor technology warrants an evaluation of personnel neutron dosimetry systems to aid in the concurrent development of a radiation protection program. For this reason, current state of knowledge neutron dosimeters have been reviewed with emphasis placed on practical utilization and the problems inherent in each type of dosimetry system. Evaluations of salient parameters such as energy response, latent image instability, and minimum detectable dose equivalent are presented for nuclear emulsion films, track etch techniques, albedo and other thermoluminescent dosimetry techniques, electrical conductivity damage effects, lyoluminescence, thermocurrent, and thermally stimulated exoelectron emission. Brief summaries of dosimetry regulatory requirements and intercomparison study results help to establish compliance and recent trends, respectively. Spectrum modeling data generated by the Neutron Physics Division of Oak Ridge National Laboratory for the Princeton Tokamak Fusion Test Reactor (TFTR) Facility have been analyzed by both International Commission on Radiological Protection fluence to dose conversion factors and an adjoint technique of radiation dosimetry, in an attempt to determine the applicability of current neutron dosimetry systems to deuterium and tritium fusion reactor leakage spectra. Based on the modeling data, a wide range of neutron energies will probably be present in the leakage spectra of the TFTR facility, and no appreciable risk of somatic injury to occupationally exposed workers is expected. The relative dose contributions due to high energy and thermal neutrons indicate that neutron dosimetry will probably not be a serious limitation in the development of fusion power

  14. Accuracy Requirements in Medical Radiation Dosimetry

    International Nuclear Information System (INIS)

    Andreo, P.

    2011-01-01

    The need for adopting unambiguous terminology on 'accuracy in medical radiation dosimetry' which is consistent with international recommendations for metrology is emphasized. Uncertainties attainable, or the need for improving their estimates, are analysed for the fields of radiotherapy, diagnostic radiology and nuclear medicine dosimetry. This review centres on uncertainties related to the first step of the dosimetry chain in the three fields, which in all cases involves the use of a detector calibrated by a standards laboratory to determine absorbed dose, air kerma or activity under reference conditions in a clinical environment. (author)

  15. Characterization of commercial MOSFETS electron dosimetry

    International Nuclear Information System (INIS)

    Carvajal, M. A.; Simancas, F.; Guirado, D.; Banqueri, J.; Vilches, M.; Lallena, A. M.; Palma, A. J.

    2011-01-01

    In recent years there have been commercial dosimetry devices based on transistors Metal-Oxide-Semiconductor (MOSFET) having a number of advantages over traditional systems for dosimetry in medical applications. These include the portability of the sensor element and a reading process quick and relatively simple dose, linearity, and so on. The use of electron beams is important in modern radiotherapy include its use in intra-operative radiotherapy (RIO). This paper presents an initial characterization of different business models MOSFET, not specific for radiation detection, to demonstrate their potential as sensors for electron beam dosimetry. (Author)

  16. Radiographic film orientation in radiotherapy dosimetry

    International Nuclear Information System (INIS)

    Suchowerska, N.; Davison, A.; Drew, J.; Metcalfe, P.

    1996-01-01

    Since the discovery of x-rays, film has been used as a detection medium for radiation. More recently radiographic film has become established as a practical tool for the measurement of dose distribution in radiotherapy. The accuracy and reproducibility of film dosimetry depends on photon energy, processing conditions and film plane orientation. The relationship between photon energy, processing conditions and film dosimetry accuracy has been studied. The role of film plane orientation is still controversial. The current work aims to clarify the effects film plane orientation has on film dosimetry. Poster 205. (author)

  17. The personal dosimetry in Mexico

    International Nuclear Information System (INIS)

    Salazar, M.A.

    2006-01-01

    The Personal Dosimetry in Mexico, has an approximately 30 year-old history; and it had been and it is at the moment, one of the more important resources with which the personnel that works with ionizing radiation sources counts for its protection. The Personal Dosimetry begins with the film dosimetry, technique that even continues being used at the present time by some users, and the main reason of its use is for economic reasons. At the moment this technique, it has been surpassed, by the Thermoluminescent dosimetry, which has taken a lot of peak, mainly by the technological development with which it is counted at the present time; what has given as a result that this technique becomes tip technology; that supported in the characteristic of the used materials, as the handling and processing of the information associated with the new PC, digitizer cards, software etc, what has allowed increases it potential. In this work the current necessities of the market are presented as well as an analysis of the future real necessities in Mexico, at national level, the companies that provide this service and that they spread to satisfy this necessity of the market, including the different used technologies are also mentioned. The application ranges, at the same time, of the advantages and disadvantages of the different systems of Personal Dosimetry in the market. The companies that at the moment provide the service of Personal Dosimetry, its use materials and equipment in indistinct form, for the monitoring of gamma radiation, beta particles, different qualities of x-ray radiation, and sometimes neutrons. The monitoring of the exposed personnel at the diverse sources of ionizing radiation mentioned is carried out in many occasions without having with the materials (detectors), neither the appropriate infrastructure and therefore without the quality control that guarantees a correct evaluation of the dose equivalent, as a result of the exposure to the ionizing radiations; it

  18. Photothermal Microneedle Etching: Improved Three-Dimensional Microfabrication Method for Agarose Gel for Topographical Control of Cultured Cell Communities

    Science.gov (United States)

    Moriguchi, Hiroyuki; Yasuda, Kenji

    2006-08-01

    We have developed a new three-dimensional (3D) microfabrication method for agarose gel, photothermal microneedle etching (PTMNE), by means of an improved photothermal spot heating using a focused 1064 nm laser beam for melting a portion of the agarose layer at the tip of the microneedle, where a photoabsorbent chromium layer is coated to be heated. The advantage of this method is that it allows the 3D control of the melting topography within the thick agarose layer with a 2 μm resolution, whereas conventional photothermal etching can enable only two-dimensional (2D) control on the surface of the chip. By this method, we can form the spheroid clusters of particular cells from isolated single cells without any physical contact with other cells in other chambers, which is important for measuring the community effect of the cell group from isolated single cells. When we set single cancer cells in microchambers of 100 μm in diameter, formed in a 50-μm-thick agarose layer, we observed that they grew, divided, and formed spheroid clusters of cells in each microchamber. The result indicates the potential of this method to be a fundamental technique in the research of multicellular spherical clusters of cells for checking the community effect of cells in 3D structures, such as the permeabilities of chemicals and substrates into the cluster, which is complementary to conventional 2D dish cultivation and can contribute to the cell-based screening of drugs.

  19. Experimental determination of order in non-equilibrium solids using colloidal gels

    International Nuclear Information System (INIS)

    Gao Yongxiang; Kilfoil, Maria

    2004-01-01

    The idea of quantifying order in disordered systems has been introduced recently by Torquato and co-workers (2000 Phys. Rev. E 62 993-1001). We are interested in the application of this idea to measure structure in non-equilibrium systems. Here we focus on gels, using as a model system colloidal gels formed from hard spheres with polymer added to the systems to induce a controlled, weak attraction. To describe the structure of the gels we use real space imaging via confocal microscopy to obtain the full three-dimensional structure. We measure experimentally both translational order and bond angle correlations, defining a new (refined) translational order parameter that is sensitive to long range order in these non-random packings. This metric is also sensitive to anisotropy, which should be important in the many physical situations where an external force is present. The bond angle distribution shows coordinated organization. To give a clearer physical picture for gels, we compare the experimental data to computer generated hard sphere systems

  20. Report on external occupational dosimetry in Canada

    International Nuclear Information System (INIS)

    1995-12-01

    In light of the new recommendations of the ICRP in Report 60 on dose quantities and dose limits, this working group was set up to examine the implications for external dosimetry in Canada. The operational quantities proposed by the ICRU are discussed in detail with regard to their applicability in Canada. The current occupational dosimetry services available in Canada are described as well as the several performance intercomparisons that have been carried out within the country as well as internationally. Recommendations are given with respect to standards for dosimetry, including accuracy and precision. More practical advice is given on the choice of dosimeter to use for external dosimetry, frequency of monitoring, and who should be monitored. Specific advice is given on the monitoring of pregnant workers and problem of non-uniform irradiation. Accident and emergency dosimetry are dealt with briefly. Suggestions are given regarding record keeping both for employers and for the national dose registry. 48 refs., 6 tabs., 1 fig

  1. ESR/tooth enamel dosimetry application to Chernobyl case: individual retrospective dosimetry of the liquidators and wild animals

    International Nuclear Information System (INIS)

    Bugai, A.; Baryakchtar, V.G.; Baran, N.

    1996-01-01

    ESR/tooth enamel dosimetry technique was used for individual retrospective dosimetry of the servicemen who had worked in 1986-1987 at the liquidation of consequences of the Chernobyl accident. For 18 investigated cases, the values varied from 0,10 (sensitivity limit) to 1,75 Gy. The same technique was used for individual dosimetry of wild animals boars, red deers, elks) hunted at contaminated 30-km area around the Chernobyl Power Plant. Measured values varied from 0,20 to 5,0 Gy/year and were compared with calculated for external and internal irradiation

  2. Dosimetry methods for fuels, cladding and structural materials

    International Nuclear Information System (INIS)

    Roettger, H.

    1980-01-01

    This volume of the proceedings of the symposium on reactor dosimetry covers the following topics: the metallurgy and dosimetry interface, radiation damage correlations of structural materials and damage analyses techniques, dosimetry for fusion materials, light water reactor pressure vessel surveillance in practice and irradiation experiments, fast reactor and reseach reactor characterization

  3. A methodology for dosimetry audit of rotational radiotherapy using a commercial detector array

    International Nuclear Information System (INIS)

    Hussein, Mohammad; Tsang, Yatman; Thomas, Russell A.S.; Gouldstone, Clare; Maughan, David; Snaith, Julia A.D.; Bolton, Steven C.; Nisbet, Andrew; Clark, Catharine H.

    2013-01-01

    Purpose: To develop a methodology for the use of a commercial detector array in dosimetry audits of rotational radiotherapy. Materials and methods: The methodology was developed as part of the development of a national audit of rotational radiotherapy. Ten cancer centres were asked to create a rotational radiotherapy treatment plan for a three-dimensional treatment-planning-system (3DTPS) test and audited. Phantom measurements using a commercial 2D ionisation chamber (IC) array were compared with measurements using 0.125 cm 3 IC, Gafchromic film and alanine pellets in the same plane. Relative and absolute gamma index (γ) comparisons were made for Gafchromic film and 2D-Array planes, respectively. Results: Comparisons between individual detectors within the 2D-Array against the corresponding IC and alanine measurement showed a statistically significant concordance correlation coefficient (both ρ c > 0.998, p < 0.001) with mean difference of −1.1 ± 1.1% and −0.8 ± 1.1%, respectively, in a high dose PTV. In the γ comparison between the 2D-Array and film it was that the 2D-Array was more likely to fail planes where there was a dose discrepancy due to the absolute analysis performed. Conclusions: It has been found that using a commercial detector array for a dosimetry audit of rotational radiotherapy is suitable in place of standard systems of dosimetry

  4. Glucinium dosimetry in beryl

    International Nuclear Information System (INIS)

    Kremer, M.

    1949-05-01

    The application of the method developed by Kolthoff and Sandell (1928) for the dosimetry of glucinium (beryllium) in beryl gives non-reproducible results with up to 20% discrepancies. This method recommends to separate beryllium and aluminium using 8 hydroxyquinoline and then to directly precipitate glucinium in the filtrate using ammonia. One possible reason of the problems generated by this method should be the formation of a volatile complex between beryllium and the oxine. This work shows that when the oxine is eliminated before the precipitation with ammonia the dosimetry of beryllium becomes accurate. The destruction of the oxine requires the dry evaporation of the filtrate, which is a long process. Thus the search for a reagent allowing the quantitative precipitation of beryllium in its solutions and in presence of oxine has been made. It has been verified also that the quantitative precipitation of the double beryllium and ammonium phosphate is not disturbed by the oxine in acetic buffer. This method, which gives good results, has also the advantage to separate beryllium from the alkaline-earth compounds still present in the filtrate. The report details the operation mode of the method: beryllium dosimetry using ammonium phosphate, aluminium-beryllium separation, application to beryl dosimetry (ore processing, insolubilization of silica, precipitation with ammonia, precipitation with oxine, precipitation of PO 4 NH 4 Gl, preciseness). (J.S.)

  5. Proceedings of the 5. symposium on neutron dosimetry. Beam dosimetry

    International Nuclear Information System (INIS)

    Schraube, H.; Burger, G.; Booz, J.

    1985-01-01

    Proceedings of the fifth symposium on neutron dosimetry, organized at Neuherberg, 17-21 September 1984, by the Commission of the European Communities and the GSF Neuherberg, with the co-sponsorship of the US Department of Energy, Office of Health and Environmental Research. The proceedings deal with research on concepts, instruments and methods in radiological protection for neutrons and mixed neutron-gamma fields, including the generation, collection and evaluation of new dosimetric data, the derivation of relevant radiation protection quantitites, and the harmonization of experimental methods and instrumentation by intercomparison programmes. Besides radiation protection monitoring, the proceedings also report on the improvement of neutron beam dosimetry in the fields of radiobiology and radiation therapy

  6. Standardized physics-dosimetry for US pressure vessel cavity surveillance programs

    International Nuclear Information System (INIS)

    Ruddy, F.H.; McElroy, W.N.; Lippincott, E.P.

    1984-01-01

    This paper summarizes the applications of ASTM standard methods, guides and practices to define the selection and deployment of recommended dosimetry sets, the selection of dosimetry capsules and thermal neutron shields, the placement of dosimetry, the methods of measurement of dosimetry sensor reaction products, data analysis procedures, and uncertainty evaluation procedures. It also describes the validation of these standards both by in-reactor testing of advanced PV cavity surveillance physics-dosimetry and by data development. The use of these standards to guide selection and development of advanced dosimetry sets for commercial reactors is also summarized. (Auth.)

  7. Optimization of Large Gel 2D Electrophoresis for Proteomic Studies of Skeletal Muscle

    Science.gov (United States)

    Reed, Patrick W.; Densmore, Allison; Bloch, Robert J.

    2013-01-01

    We describe improved methods for large format, 2-dimensional gel electrophoresis (2-DE) that improve protein solubility and recovery, minimize proteolysis, and reduce the loss of resolution due to contaminants and manipulations of the gels, and thus enhance quantitative analysis of protein spots. Key modifications are: (i) the use of 7M urea + 2 M thiourea, instead of 9M urea, in sample preparation and in the tops of the gel tubes; (ii) standardized deionization of all solutions containing urea with a mixed bed ion exchange resin and removal of urea from the electrode solutions; and (iii) use of a new gel tank and cooling device that eliminate the need to run two separating gels in the SDS dimension. These changes make 2D-GE analysis more reproducible and sensitive, with minimal artifacts. Application of this method to the soluble fraction of muscle tissues reliably resolves ~1800 protein spots in adult human skeletal muscle and over 2800 spots in myotubes. PMID:22589104

  8. Cross sections required for FMIT dosimetry

    International Nuclear Information System (INIS)

    Gold, R.; McElroy, W.N.; Lippincott, E.P.; Mann, F.M.; Oberg, D.L.; Roberts, J.H.; Ruddy, F.H.

    1980-01-01

    The Fusion Materials Irradiation Test (FMIT) facility, currently under construction, is designed to produce a high flux of high energy neutrons for irradiation effects experiments on fusion reactor materials. Characterization of the flux-fluence-spectrum in this rapidly varying neutron field requires adaptation and extension of currently available dosimetry techniques. This characterization will be carried out by a combination of active, passive, and calculational dosimetry. The goal is to provide the experimenter with accurate neutron flux-fluence-spectra at all positions in the test cell. Plans have been completed for a number of experimental dosimetry stations and provision for these facilities has been incorporated into the FMIT design. Overall needs of the FMIT irradiation damage program delineate goal accuracies for dosimetry that, in turn, create new requirements for high energy neutron cross section data. Recommendations based on these needs have been derived for required cross section data and accuracies

  9. Transdermal delivery of paeonol using cubic gel and microemulsion gel

    Science.gov (United States)

    Luo, Maofu; Shen, Qi; Chen, Jinjin

    2011-01-01

    Background The aim of this study was to develop new systems for transdermal delivery of paeonol, in particular microemulsion gel and cubic gel formulations. Methods Various microemulsion vehicles were prepared using isopropyl myristate as an oil phase, polyoxyethylated castor oil (Cremophor® EL) as a surfactant, and polyethylene glycol 400 as a cosurfactant. In the optimum microemulsion gel formulation, carbomer 940 was selected as the gel matrix, and consisted of 1% paeonol, 4% isopropyl myristate, 28% Cremophor EL/polyethylene glycol 400 (1:1), and 67% water. The cubic gel was prepared containing 3% paeonol, 30% water, and 67% glyceryl monooleate. Results A skin permeability test using excised rat skins indicated that both the cubic gel and microemulsion gel formulations had higher permeability than did the paeonol solution. An in vivo pharmacokinetic study done in rats showed that the relative bioavailability of the cubic gel and microemulsion gel was enhanced by about 1.51-fold and 1.28-fold, respectively, compared with orally administered paeonol suspension. Conclusion Both the cubic gel and microemulsion gel formulations are promising delivery systems to enhance the skin permeability of paeonol, in particular the cubic gel. PMID:21904450

  10. Special workshop on lung dosimetry

    International Nuclear Information System (INIS)

    Fisher, D.R.

    1983-01-01

    A Special Workshop on Lung Dosimetry was convened in Salt Lake City, Utah, on April 21-22, 1982, to stimulate the use of improved radiation dosimetry and to formulate a stronger basis for dose-response relationships for inhaled radionuclides. The two-day workshop was held in conjunction with the 30th Annual Meeting of the Radiation Research Society. Publication is planned

  11. Dosimetry of internal emitters

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    The Dosimetry of Internal Emitter Program endeavors to refine the correlation between radiation dose and observed biological effects. The program is presently engaged in the development of studies that will demonstrate the applicability of microdosimetry models developed under the Microdosimetry of Internal Sources Program. The program also provides guidance and assistance to Pacific Northwest Laboratory's Biology Department in the dosimetric analysis of internally deposited radionuclides. This report deals with alpha particle dosimetry plutonium 239 inhalation, and in vitro studies of chromosomal observations

  12. Nuclear medicine radiation dosimetry

    CERN Document Server

    McParland, Brian J

    2010-01-01

    Complexities of the requirements for accurate radiation dosimetry evaluation in both diagnostic and therapeutic nuclear medicine (including PET) have grown over the past decade. This is due primarily to four factors: growing consideration of accurate patient-specific treatment planning for radionuclide therapy as a means of improving the therapeutic benefit, development of more realistic anthropomorphic phantoms and their use in estimating radiation transport and dosimetry in patients, design and use of advanced Monte Carlo algorithms in calculating the above-mentioned radiation transport and

  13. Information from the Dosimetry Service

    CERN Multimedia

    2006-01-01

    Please note the following opening hours of the Service: In June: Every morning from 8:30 to 12:00 In July: Mondays, Wednesdays and Fridays from 8:30 to 11:30 Closed all day on Tuesdays and Thursdays From 31st July onwards: Every morning from 8:30 to 12:00 The Service is closed in the afternoons. We should like to remind you that dosimeters cannot be sent to customers by internal mail. Short-term dosimeters (VCTs) must always be returned to the Service after use and must not be left on the racks in the experimental areas or in the secretariats. Dosimetry Service Tel 72155 Bldg. 24 E 011 Dosimetry.service@cern.ch http://cern.ch/rp-dosimetry

  14. INDIVIDUAL DOSIMETRY SERVICE

    CERN Multimedia

    2000-01-01

    Personnel in the distribution groups Aleph, Delphi, L3, Opal who also work for other experiments than at LEP, should contact their dispatchers to explain their activities for the future, after LEP dismantling in order to be maintained on the regular distribution list at Individual DosimetryWe inform all staff and users under regular dosimetric control that the dosimeters for the monitoring period MAY/JUNE will be available from their usual dispatchers on Tuesday 2 May.Please have your films changed before the 12 May.The colour of the dosimeter valid in is MAY/JUNE is YELLOW.Individual Dosimetry Service will be closed on Friday 28 April.

  15. Dosimetry system of the RB reactor

    International Nuclear Information System (INIS)

    Lolic, B.; Vukadin, D.

    1962-01-01

    Although RB reactor is operated at very low power levels, safety and dosimetry systems have high importance. This paper shows detailed dosimetry system with fundamental typical components. Estimated radiation doses dependent on reactor power are given at some characteristic points in the rooms nearby reactor

  16. Experimental verification of internal dosimetry calculations. Annual progress report

    International Nuclear Information System (INIS)

    1980-05-01

    During the past year a dosimetry research program has been established in the School of Nuclear Engineering at the Georgia Institute of Technology. The major objective of this program has been to provide research results upon which a useful internal dosimetry system could be based. The important application of this dosimetry system will be the experimental verification of internal dosimetry calculations such as those published by the MIRD Committee

  17. Dosimetry: an ARDENT topic

    CERN Multimedia

    CERN Bulletin

    2012-01-01

    The first annual ARDENT workshop took place in Vienna from 20 to 23 November. The workshop gathered together the Early-Stage Researchers (ESR) and their supervisors, plus other people involved from all the participating institutions.   “The meeting, which was organised with the local support of the Austrian Institute of Technology, was a nice opportunity for the ESRs to get together, meet each other, and present their research plans and some preliminary results of their work,” says Marco Silari, a member of CERN Radiation Protection Group and the scientist in charge of the programme. Two full days were devoted to a training course on radiation dosimetry, delivered by renowned experts. The workshop closed with a half-day visit to the MedAustron facility in Wiener Neustadt. ARDENT (Advanced Radiation Dosimetry European Network Training) is a Marie Curie ITN project funded under EU FP7 with €4 million. The project focuses on radiation dosimetry exploiting se...

  18. Neutron dosimetry in biology

    International Nuclear Information System (INIS)

    Sigurbjoernsson, B.; Smith, H.H.; Gustafsson, A.

    1965-01-01

    To study adequately the biological effects of different energy neutrons it is necessary to have high-intensity sources which are not contaminated by other radiations, the most serious of which are gamma rays. An effective dosimetry must provide an accurate measure of the absorbed dose, in biological materials, of each type of radiation at any reactor facility involved in radiobiological research. A standardized biological dosimetry, in addition to physical and chemical methods, may be desirable. The ideal data needed to achieve a fully documented dosimetry has been compiled by H. Glubrecht: (1) Energy spectrum and intensity of neutrons; (2) Angular distribution of neutrons on the whole surface of the irradiated object; (3) Additional undesired radiation accompanying the neutrons; (4) Physical state and chemical composition of the irradiated object. It is not sufficient to note only an integral dose value (e.g. in 'rad') as the biological effect depends on the above data

  19. An effective placental cotyledons proteins extraction method for 2D gel electrophoresis.

    Science.gov (United States)

    Tan, Niu J; Daim, Leona D J; Jamil, Amilia A M; Mohtarrudin, Norhafizah; Thilakavathy, Karuppiah

    2017-03-01

    Effective protein extraction is essential especially in producing a well-resolved proteome on 2D gels. A well-resolved placental cotyledon proteome, with good reproducibility, have allowed researchers to study the proteins underlying the physiology and pathophysiology of pregnancy. The aim of this study is to determine the best protein extraction protocol for the extraction of protein from placental cotyledons tissues for a two-dimensional gel electrophoresis (2D-GE). Based on widely used protein extraction strategies, 12 different extraction methodologies were carefully selected, which included one chemical extraction, two mechanical extraction coupled protein precipitations, and nine chemical extraction coupled protein precipitations. Extracted proteins were resolved in a one-dimensional gel electrophoresis and 2D-GE; then, it was compared with set criteria: extraction efficacy, protein resolution, reproducibility, and recovery efficiency. Our results revealed that a better profile was obtained by chemical extraction in comparison to mechanical extraction. We further compared chemical extraction coupled protein precipitation methodologies, where the DNase/lithium chloride-dense sucrose homogenization coupled dichloromethane-methanol precipitation (DNase/LiCl-DSH-D/MPE) method showed good protein extraction efficiency. This, however, was carried out with the best protein resolution and proteome reproducibility on 2D-gels. DNase/LiCl-DSH-D/MPE was efficient in the extraction of proteins from placental cotyledons tissues. In addition, this methodology could hypothetically allow the protein extraction of any tissue that contains highly abundant lipid and glycogen. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Hanford External Dosimetry Technical Basis Manual PNL-MA-842

    International Nuclear Information System (INIS)

    Rathbone, Bruce A.

    2006-01-01

    The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNL's Hanford External Dosimetry Program which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNL's Electronic Records & Information Capture Architecture (ERICA) database