WorldWideScience

Sample records for digital subtraction technique

  1. Digital Subtraction Radiography - A Technique Revisited

    Directory of Open Access Journals (Sweden)

    Anshul Mehra

    2007-01-01

    Full Text Available Digital imaging has changed the scenario of medical and dental imaging as it has been able to address many limitations associated with traditional film based radiograph. However, subtle changes on the image are still difficult to appreciate by the human eye because the changes are buried in a background of normal anatomic structures, and are not clearly evident. Digital subtraction radiography is one of the image enhancing technique which addresses this problem and has found its use in various fields of dentistry in the recent past. However, there is lack of review in the literature regarding this widely used technique. The purpose of this article is to present an overview of this technique and its uses in various fields of dentistry.

  2. Digital subtraction angiography (DSA)

    International Nuclear Information System (INIS)

    Lackner, K.; Janson, R.; Franken, T.; Harder, T.; Thurn, P.

    1983-01-01

    Digital subtraction angiography is an advanced subtraction technique and a new field in which i.v. injection of contrast media is required. Conventional techniques involving i.v. injection of contrast media have the following drawbacks: 1. High amounts of contrast media; 2. simultaneous injection into the brachial veins of both arms; 3. poor imaging of blood vessels in regions with strongly varying X-ray absorption characteristics of the background; 4. no possibility of contrast amplification. In conventional subtraction techniques, image processing takes place as a second step after the examination, so that results are not immediately available for interpretation. Digital subtraction angiography largely avoids these drawbacks. (orig./MG) [de

  3. Intraarterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Davis, P.C.

    1987-01-01

    Digital subtraction angiography (DSA) refers to a radiographic technique of amplifying low levels of contrast from intravascular iodine into an acceptable image of vascular anatomy. Initial enthusiasm suggested that DSA using intravenous injections (IV-DSA) would eliminate most conventional film-screen angiographic studies. It was soon apparent, however, that IV-DSA examinations were often compromised in those patients who most needed a less invasive study. Indeed, only a 70 to 85 percent accuracy rate was achieved with IV-DSA, primarily due to motion artifact, poor cardiac output, overlap of pertinent vessels, and inability to resolve smaller vessels

  4. Evaluation of coronary blood flow using digital subtraction technique and cine coronary angiography

    International Nuclear Information System (INIS)

    Uwatoko, Masashi; Miyagi, Yutaka; Nomura, Masanori

    1988-01-01

    To evaluate coronary circulation in ischemic heart disease, digital image processing with cine coronary angiography was performed. Using time-density curves obtained from individual pixels, images showing the distribution of contrast density and transit time were obtained. To record angiograms, contrast medium was injected into the coronary artery in a steady manner during right atrial pacing. Frames in the end-diastolic phase immediately before the P wave were selected, and digitized into a 512 x 512 x 8 bit matrix using a system composed of a video camera, an analog-to-digital converter, and a computer. These digitized images were then stored in a disk memory. A mask image was prepared before the injection of contrast medium. Subtraction was performed using the mask image and a series of images following contrast injection. The subtracted images were of sufficient quality to permit clear observation of the individual coronary arterial branches. Time-density curves were then determined from these subtracted images. From these curves, time from the onset of contrast injection to its peak density (Tp), time from the peak density to the half peak density (T1/2) and the attenuation factor of the curves (τ) were derived. Their distributions were expressed as color images. Examples of normal control and a case of inferior infarction were demonstrated. Blood flow function images with good spatial resolution were thus obtained. This method is useful for evaluating coronary blood flow. (author)

  5. Exercise intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Yiannikas, J.

    1986-01-01

    Attempts to use exercise ventriculography have been made, not only to give diagnostic and perhaps even prognostic information in patients with coronary artery disease, but also in patients with valvular heart disease both before and after surgical intervention. Clearly an accurate method of assessing ventricular function under conditions of stress in various cardiac diseases would provide important information that would help in patient management. Exercise ventriculography using gated blood pool equilibrium technetium studies are widely used, but are limited by spatial resolution and by the foreshortening affects of visualizing the left ventricular chamber in the left anterior oblique view. First pass radionuclide studies have the added advantage of being able to visualize the ventricular chamber in the anterior or even the right anterior oblique view, but are even more limited by their spatial resolution problems. Several investigations have shown that digital subtraction angiography produces left ventricular images with a spatial resolution almost identical to that of conventional contrast ventriculography, but without the inherent problems of cardiac arrhythmias, which often limit the assessment of left ventricular function. Because of its ability to accurately delineate wall motion abnormalities, the technique may provide an adequate assessment of global and regional left ventricular function after exercise. Digital subtraction angiography may identify ischemic wall motion abnormalities produced by exercise in patients who already had significant permanent left ventricular damage from myocardial infarction

  6. Digital subtraction angiography in ischemic cerebrovascular accidents

    International Nuclear Information System (INIS)

    Manelfe, C.; Bonafe, A.; Ducos de Lahitte, M.; Rascol, A.; Prere, J.; Guiraud, B.; Marc-Vergnes, J.P.

    1983-01-01

    Recent advances in computer and radiological technology have permitted reassessment of intravenous angiography in the evaluation of cerebrovascular disorders. Although digital subtraction angiography is a relatively new technique, it has rapidly gained a widespread acceptance. It has extended the use of angiography to outpatients and to people in whom conventional angiography is contraindicated. This reliable, safe, and relatively noninvasive technique offers the user two benefits: real-time subtraction and enhanced image quality. The system allows angiographic evaluation of the extracranial and intracranial vessels by means of intravenous injection of contrast material. Extracranial studies clearly demonstrate stenoses and occlusions of the major cervicocephalic arteries. Intracranial studies usually detect major cerebrovascular occlusions and provide insight into the collateral flow patterns. Intravenous digital subtraction angiography permits accurate assessment of cervicocephalic vessels after surgical repair. Although intravenous digital subtraction angiography obviates the need for conventional angiography in many cases, movements from the patients, or superimposition of vascular structures can substantially degrade the quality of the images. Digital subtraction angiography with intra-arterial injection of contrast medium will be contemplated in patients with poor intravenous digital subtraction angiography studies prior to surgery [fr

  7. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  8. Digital subtraction angiography of the heart and lungs

    International Nuclear Information System (INIS)

    Moodie, D.S.; Yiannikas, J.

    1986-01-01

    This book contains 12 chapters. Some of the chapter titles are: Physical Principles of Cardiac Digital Subtraction Angiography, The Use of Intravenous Digital Subtraction Angiography in Evaluating Patients with Complex Congenital Heart Disease, Exercise Intravenous Digital Subtraction Angiograpny, Cardiomyopathic and Cardiac Neoplastic Disease, Digital Subtraction Angiography in the Catheterization Laboratory, and Cardiac Digital Subtraction Angiography - Future Directions

  9. Physical principles of cardiac digital subtraction angiography

    International Nuclear Information System (INIS)

    Buonocore, E.; Pavlicek, W.

    1986-01-01

    Advances in the applications of computers with standard radiologic equipment have resulted in the development of electronic, or so-called ''film-less'' imaging. This technique, discussed by the authors, has become of particular value in the visualization of the central vascular system and has become known as digital subtraction angiography (DSA). Commercial products have become increasingly available and are capable of converting T.V. signals, obtained by conventional fluorography, to a computed array of digital values. Addition, subtraction, and averaging of this data, result in images with adequate signal-to-noise ratios that achieve detection of low concentrations of contrast media not possible with conventional screen film techniques. Computer subtraction of unnecessary background information improves the conspicuity of the opacified vessels to permit detection of vascular structures containing a concentration of no more than 1-3 percent of contrast media. This improved visualization is possible even with intravenous peripheral injections or reduced amounts of contrast media given intraarterially. With either method of contrast media administration, DSDA has become an excellent means of anatomic demonstration of the heart and great vessels with decreased morbidity and at lower cost

  10. Digital subtraction angiography of carotid bifurcation

    International Nuclear Information System (INIS)

    Vries, A.R. de.

    1984-01-01

    This study demonstrates the reliability of digital subtraction angiography (DSA) by means of intra- and interobserver investigations as well as indicating the possibility of substituting catheterangiography by DSA in the diagnosis of carotid bifurcation. Whenever insufficient information is obtained from the combination of non-invasive investigation and DSA, a catheterangiogram will be necessary. (Auth.)

  11. Digital subtraction angiography: myths and reality

    International Nuclear Information System (INIS)

    Levin, D.C.

    1984-01-01

    Some of the claims made about digital subtraction angiography (DSA) when it was first developed have turned out to be greatly exaggerated, and some members of the radiologic community have become disillusioned with its capabilities. The author discusses some of the limitations of DSA, and concludes that the advantages of DSA outweigh its limitations

  12. Development of Shimadzu digital subtraction system

    International Nuclear Information System (INIS)

    Nishioka, Hiroyuki; Shibata, Koichi; Shimizu, Yasumitsu; Shibata, Kenji; Wani, Hidenobu

    1985-01-01

    Shimadzu has recently developed a digital subtraction system. It can perform intra-arterial digital subtraction angiography (DSA) using low concentration of contrast medium, or can visualize arteries with intravenuous injection. It can extremely reduce patient's pain in angiography. Image quality of DSA has been much improved by the development of high quality image amplifiers, improvement of signal-to-noise ratio of the x-ray television unit and the development of digital disk recorders. The peak-hold subtraction method that is now under clinical study presents images of blood vessels as the trace of the flow of contrast medium. The maximum-hold memory where the maximum value of the brightness in some period is stored for every picture element is subtracted from the minimum-hold memory where the minimum value is stored, and thus images of blood vessels can be obtained. Hardware of this method is rather simple and it is expected that the amount of contrast medium may be reduced or x-ray dose of the patient may be decreased. (author)

  13. Statistically tuned Gaussian background subtraction technique for ...

    Indian Academy of Sciences (India)

    Keywords. Tuning factor; background segmentation; unmanned aerial vehicle; aerial surveillance; thresholding. Abstract. Background subtraction is one of the efficient techniques to segment the targets from non-informative background of a video. The traditional background subtraction technique suits for videos with static ...

  14. Digital subtraction radiography in the study of the lacrimal system

    International Nuclear Information System (INIS)

    Falaschi, F.; Pieri, L.; Perri, G.; Signorini, G.; Genovese Ebert, F.

    1988-01-01

    The authors emphasize the usefulness of digital dacrycystography (DCG), as compared with various current technoques. Utilizing a radiographic unit equipped with a video-fluoroscopic system and interfaced to a digital video-processor, several digitalized images are acquired before, during and after the injection of contrast medium. Final images are obtained by subtraction of suitable pairs of source frames. Twenty-six patients affected by epiphora have been examined so far. In 21 cases digital subtraction DCG allowed an accurate visualization of the lacrimal system; in the other five patients the amount of information was acceptable. This methodology allows the assessment of both the normal anatomy of the lacrimal passages and their pathological patterns, such as obstructions, stenoses, fistulas, chronic dacrycystites, lacrimal stones. The examination is easy and quick to perform, with no discomfort for the patient. Digital subtraction DCG proves thus to be a very valuable technique thanks to its possible electronic elaboration - i.e. the subtraction and the magnification of images - to its better contrast resolution, and to the possibility it yields of dynamic studies under radioscopic control

  15. Digital subtraction angiography of the thoracic aorta

    International Nuclear Information System (INIS)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-01-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram

  16. Digital subtraction angiography of the thoracic aorta

    Energy Technology Data Exchange (ETDEWEB)

    Grossman, L.B.; Buonocore, E.; Modic, M.T.; Meaney, T.F.

    1984-02-01

    Forty-three patients with acquired and congenital abnormalities of the thoracic aorta were studied using digital subtraction angiography (DSA) after an intravenous bolus injection of 40 ml of contrast material. Abnormalities studied included coarctation, pseudocoarctation, Marfan syndrome, cervical aorta, double aortic arch, aneurysm, dissection, and tumor. Twenty-four patients also had conventional angiography. DSA was accurate in 95% of cases; in the other 5%, involving patients with acute type I dissection, the coronary arteries could not be seen. The authors concluded that in 92% of their patients, DSA could have replaced the standard aortogram.

  17. Method and apparatus for performing digital intravenous subtraction angiography

    International Nuclear Information System (INIS)

    Stein, J.A.

    1986-01-01

    This invention relates to digital intravenous subtraction angiography (DISA), and more particularly concerns novel apparatus and techniques for providing high resolution angiograms with equipment that coacts with existing standard medical X-ray equipment. A typical medical X-ray generator provides low mA, continuous X-ray exposures illuminating a standard image intensifier producing an image scanned by a conventional television camera to produce a video signal. An analog-to-digital converter digitizes the signal, and adding means adds the digital frame signals together in real time to provide an intermediate digital signal representing the addition of 5 to 20 frames. Digital storage means store the intermediate image signals. Preferably there are two system memories with means for summing a subsequent intermediate image in the second memory while a previously-formed intermediate image is being transferred to disk storage

  18. Digital subtraction angiography in the assessment of cardiovascular disease

    International Nuclear Information System (INIS)

    Harrington, D.P.; Boxt, L.M.

    1985-01-01

    Digital subtraction angiography (DSA) is a new radiographic method for evaluating the cardiovascular system. It represents another in a continuing series of computer-assisted diagnostic imaging modalities. The advantages of this technique are its relatively noninvasive nature combined with diagnostically acceptable angiographic images of a variety of cardiovascular structures. Major clinical applications of DSA include its use in imaging of localized regions of peripheral arterial disease and as a screening procedure in evaluating extracranial carotid and vertebral artery disease and renovascular hypertension. Cardiac applications of DSA include assessment of ventricular function, recognition and quantification of intracardiac shunts, visualization of coronary artery bypass grafts, and the study of complex congenital cardiac malformations. Digital subtraction angiography may also be used to evaluate intracranial aneurysms and vascular tumors

  19. Evaluation and quality control of digital subtraction angiography systems

    International Nuclear Information System (INIS)

    Louisot, P.

    1986-04-01

    After reviewing the development of systems used in angiography, we rewind the medical interest and describe the steps of an angiographic examination. The following chapter is dedicated to the techniques used for the digitalization of video images. The components of the system involved in the image acquisition are thoroughly investigated in chapter 4. Then, we analyse the capabilities of the machines available in France in 1985. Chapter 6 is devoted to the criteria of quality in digital imaging. In order to assign qualitative values to the above criteria, we design a control procedure which is described in chapter 7. The procedure thus allows the estimate of the physical performances of angiographic digital subtraction systems [fr

  20. Digital subtraction angiography in head and neck radiology

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, R.F.; Seeger, J.F.; Smith, R.L.; Horsley, W.W.; Miller, R.W.

    1984-07-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally.

  1. Digital subtraction angiography in head and neck radiology

    International Nuclear Information System (INIS)

    Carmody, R.F.; Seeger, J.F.; Smith, R.L.; Horsley, W.W.; Miller, R.W.

    1984-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally. (orig.)

  2. Temporal subtraction technique for detection of subtle anomalies on temporally sequential bone-subtracted chest radiographs by energy subtraction

    International Nuclear Information System (INIS)

    Sanada, Shigeru; Kobayashi, Takeshi; Yoshida, Megumi; Takashima, Tsutomu; Matsui, Takeshi

    2000-01-01

    We developed a temporal subtraction technique for the detection of subtle anomalies on temporally sequential bone-subtracted chest radiographs (soft tissue images) by energy subtraction. To recognize the temporal changes in a current soft tissue image in comparison with those in a previous soft tissue image, we attempted to enhance the changes by a difference image processing technique. The lung markings were enhanced by the first derivative filter. The image registration for the lung markings on both images by the sequential similarity detection algorithm (SSDA) method was then employed. The soft tissue image provided by the energy subtraction technique was excellent in its detection of subtle abnormalities in the lung, and this method was able to detect subtle abnormalities such as infiltrates and nodules missed in screening. It was suggested that this temporal subtraction technique improves accuracy when radiologists diagnose soft tissue chest images by x-ray energy subtraction. (author)

  3. Pulmonary ventilation in children digital subtraction study

    International Nuclear Information System (INIS)

    Schmit, P.; Faure, C.; Sardet, A.; Bacques, O.

    1985-01-01

    Digital technique such as used in digital angiography can be used to study areas which lucency varies with time. A TID technique (time interval difference) has been used to study the lucency variation of the lung in children. This method has been used in 130 children with a mean age of 2 years and 8 months. In 85 children, the TID was normal: 5 false negative studies were found in this group. In the other 47 cases, the anomaly of the TID was due to a perfusion or a ventilation anomaly or both. No false positive are found. In 13 patients, comparison between the TID findings and the perfusion and ventilation nuclear scan was possible. In 9 patients, the correlation was excellent, the TID giving more some informations about the pulmonary mixic [fr

  4. Digital Subtraction Angiography (DSA) "Road Map": An Angiographic Tool

    Science.gov (United States)

    Turski, P. A.; Stieghorst, M. F.; Strother, C. M.; Crummy, A. B.; Lieberman, R. P.; Mistretta, C. A.

    1982-12-01

    Continuous Digital subtraction combined with intraarterial injections of contrast medium permits the display of arterial structures during real time fluoroscopy. This DSA "road map" facilitates selective catheterization and has proved useful in interventional procedures.

  5. IMPROVED BACKGROUND SUBTRACTION FOR THE SLOAN DIGITAL SKY SURVEY IMAGES

    International Nuclear Information System (INIS)

    Blanton, Michael R.; Kazin, Eyal; Muna, Demitri; Weaver, Benjamin A.; Price-Whelan, Adrian

    2011-01-01

    We describe a procedure for background subtracting Sloan Digital Sky Survey (SDSS) imaging that improves the resulting detection and photometry of large galaxies on the sky. Within each SDSS drift scan run, we mask out detected sources and then fit a smooth function to the variation of the sky background. This procedure has been applied to all SDSS-III Data Release 8 images, and the results are available as part of that data set. We have tested the effect of our background subtraction on the photometry of large galaxies by inserting fake galaxies into the raw pixels, reanalyzing the data, and measuring them after background subtraction. Our technique results in no size-dependent bias in galaxy fluxes up to half-light radii r 50 ∼ 100 arcsec; in contrast, for galaxies of that size the standard SDSS photometric catalog underestimates fluxes by about 1.5 mag. Our results represent a substantial improvement over the standard SDSS catalog results and should form the basis of any analysis of nearby galaxies using the SDSS imaging data.

  6. Digital contrast subtraction radiography for proximal caries diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Cheol; Yoon, Suk Ja [Department of Dental Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2002-06-15

    To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Thirty-six teeth with 57 proximal surfaces were radiographied using a size no.2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  7. Digital contrast subtraction radiography for proximal caries diagnosis

    International Nuclear Information System (INIS)

    Kang, Byung Cheol; Yoon, Suk Ja

    2002-01-01

    To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Thirty-six teeth with 57 proximal surfaces were radiographied using a size no.2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  8. [A digital subtraction angiography system based on LUT algorithms].

    Science.gov (United States)

    Chen, Xiangan; Li, Kaiyang; Zhou, Li; Chen, Jiansheng

    2006-04-01

    Look-up table (LUT) algorithms have been widely used in digital signal processing, but the article on the application of LUT algorithms in digital subtraction angiography was rarely reported. In this article, the effect of different LUT algorithms on digital subtraction angiography images is introduced. The result reveals that different LUT algorithms can bring about different effects of image. Based on analysis and comparison, we deem it possible to acquire improved images of DSA by use of some LUT algorithms with image processing.

  9. Spectral amplitude coding OCDMA using and subtraction technique.

    Science.gov (United States)

    Hasoon, Feras N; Aljunid, S A; Samad, M D A; Abdullah, Mohamad Khazani; Shaari, Sahbudin

    2008-03-20

    An optical decoding technique is proposed for a spectral-amplitude-coding-optical code division multiple access, namely, the AND subtraction technique. The theory is being elaborated and experimental results have been done by comparing a double-weight code against the existing code, Hadamard. We have proved that the and subtraction technique gives better bit error rate performance than the conventional complementary subtraction technique against the received power level.

  10. Digital subtraction angiography - a new approach to brain death determination in the newborn

    International Nuclear Information System (INIS)

    Albertini, A.; Schonfeld, S.; Hiatt, M.; Hegyi, T.

    1993-01-01

    The diagnosis of brain death in the newborn infants is elusive and often difficult. The lack of cerebral blood flow has become an identified criterion for loss of cerebral function. The diagnosis can be obtained by the technique of digital subtraction angiography, which is presented in two case reports demonstrating the utility of this technique. (orig.)

  11. Digital subtraction angiography and intraarterial contrast medium injection for coronary examinations

    Energy Technology Data Exchange (ETDEWEB)

    Tobio, R.; Kallmeyer, C.; Castello, J.

    1985-01-01

    Digital subtraction angiography (DSA) is an established method of vasography, most extensively used as i.v. DSA. Intraarterial injection, however, applying selective or non-selective contrast medium injection, seems to be at least as important a technique although it has not yet met with corresponding interest. The article explains advantages of the technique for angiographic examinations, in particular of coronary angiography.

  12. Digital subtraction angiography in the diagnosis of Fallot's tetralogy

    International Nuclear Information System (INIS)

    Ivanitskij, A.V.; Tereshkin, Ya.A.; Sobolev, A.V.; Stolyar, V.L.; Slyunyastikov, M.A.

    1995-01-01

    The authors analyze the efficacy of digital subtraction angiography (DSA) in the diagnosis of Fallot's tetralogy (FT); this method helps simplity and cut down their scope of investigations but does not deteriorate their informative value. DSA findings in 120 patients with TF are analyzed. 5 refs.; 6 figs

  13. Statistically tuned Gaussian background subtraction technique for ...

    Indian Academy of Sciences (India)

    The non-parametric background modelling approach proposed by Martin Hofmann et al (2012) involves modelling of foreground by the history of recently ... background subtraction system with mixture of Gaussians, deviation scaling factor and max– min background model for outdoor environment. Selection of detection ...

  14. Image noise reduction algorithm for digital subtraction angiography: clinical results.

    Science.gov (United States)

    Söderman, Michael; Holmin, Staffan; Andersson, Tommy; Palmgren, Charlotta; Babic, Draženko; Hoornaert, Bart

    2013-11-01

    To test the hypothesis that an image noise reduction algorithm designed for digital subtraction angiography (DSA) in interventional neuroradiology enables a reduction in the patient entrance dose by a factor of 4 while maintaining image quality. This clinical prospective study was approved by the local ethics committee, and all 20 adult patients provided informed consent. DSA was performed with the default reference DSA program, a quarter-dose DSA program with modified acquisition parameters (to reduce patient radiation dose exposure), and a real-time noise-reduction algorithm. Two consecutive biplane DSA data sets were acquired in each patient. The dose-area product (DAP) was calculated for each image and compared. A randomized, blinded, offline reading study was conducted to show noninferiority of the quarter-dose image sets. Overall, 40 samples per treatment group were necessary to acquire 80% power, which was calculated by using a one-sided α level of 2.5%. The mean DAP with the quarter-dose program was 25.3% ± 0.8 of that with the reference program. The median overall image quality scores with the reference program were 9, 13, and 12 for readers 1, 2, and 3, respectively. These scores increased slightly to 12, 15, and 12, respectively, with the quarter-dose program imaging chain. In DSA, a change in technique factors combined with a real-time noise-reduction algorithm will reduce the patient entrance dose by 75%, without a loss of image quality. RSNA, 2013

  15. Intravenous digital subtraction angiography investigation of reversible cerebral ischemia

    International Nuclear Information System (INIS)

    Pistolesi, G.F.; Maso, R.; Filosto, L.; Piovan, E.; Morgante, D.; Taddei, G.; Tonegutti, M.; Portuese, A.

    1986-01-01

    The brachio-cephalic, carotid, vertebral and intra-cranial vessels of 497 patients presenting reversible ischemic attacks (R.I.A) were evaluated with venous digital subtraction angiography (V.D.S.A.). Alterations of the vascular wall were observed in 289/497 (58.2%) patients, of whom 60% presented multiple locations (539 lesions): obstruction (12%), stenosis >50% (29%), stenosis 50%. The incidence of vascular lesions was higher (p [fr

  16. Digital subtraction angiography in pediatric cerebrovascular occlusive disease

    International Nuclear Information System (INIS)

    Faerber, E.N.; Griska, L.A.B.; Swartz, J.D.; Capitanio, M.A.; Popky, G.L.

    1984-01-01

    While conventional angiography has been used to demonstrate cerebrovascular occlusive disease in the past, digital subtraction angiography (DSA) is capable of showing progressive vascular involvement with ease, simplicity, and extremely low morbidity, making it particularly well suited for children and outpatients either alone or coordinated with computed tomography. The authors discuss the usefulness and advantages of DSA as demonstrated in 7 infants and children with hemiplegia, 4 of whom had sickle-cell disease

  17. Digital Subtraction Fluoroscopic System With Tandem Video Processing Units

    Science.gov (United States)

    Gould, Robert G.; Lipton, Martin J.; Mengers, Paul; Dahlberg, Roger

    1981-07-01

    A real-time digital fluoroscopic system utilizing two video processing units (Quantex) in tandem to produce continuous subtraction images of peripheral and internal vessels following intravenous contrast media injection has been inves-tigated. The first processor subtracts a mask image consisting of an exponentially weighted moving average of N1 frames (N1 = 2k where k = 0.7) from each incoming video frame, divides by N1, and outputs the resulting difference image to the second processor. The second unit continuously averages N2 incoming frames (N2 = 2k) and outputs to a video monitor and analog disc recorder. The contrast of the subtracted images can be manipulated by changing gain or by a non-linear output transform. After initial equipment adjustments, a subtraction sequence can be produced without operator interaction with the processors. Alternatively, the operator can freeze the mask and/or the subtracted output image at any time during the sequence. Raw data is preserved on a wide band video tape recorder permitting retrospective viewing of an injection sequence with different processor settings. The advantage of the tandem arrangement is that it has great flexibility in varying the duration and the time of both the mask and injection images thereby minimizing problems of registration between them. In addition, image noise is reduced by compiling video frames rather than by using a large radiation dose for a single frame, which requires a wide dynamic range video camera riot commonly available in diagnostic x-ray equipment. High quality subtraction images of arteries have been obtained in 15 anesthetized dogs using relatively low exposure rates (10-12 μR/video frame) modest volumes of contrast medium (0.5-1 ml/kg), and low injection flow rates (6-10 ml/sec). The results/ achieved so far suggest that this system has direct clinical applications.

  18. Introduction to the principles of Digital Subtraction Angiography (DSA)

    International Nuclear Information System (INIS)

    Kaplanis, P.

    1997-01-01

    Medical applications of advanced technology have rapidly become more sophisticated and more widespread. The field of diagnostic imaging is by no means an exception. There has been a number of breathtaking developments in the field of medical imaging in recent years. Today higher quality, greater clarity and more minute precision are considered not advantages but necessities. Hence new developments are concentrated in the data acquisition and image processing based on the microprocessor controlled modules interfaced with state of the art radiological imaging equipment. One such development is the subtraction of x-rays vis a computer for better visualization of blood vessels, cavities of the heart and of the coronary and pulmonary vascular system. This procedure is termed Digital Subtraction Angiography (DSA). (author)

  19. Assessment of simulated internal resorption cavities using digital and digital subtraction radiography: a comparative study.

    Science.gov (United States)

    Stephanopoulos, Georgios; Mikrogeorgis, Georgios; Lyroudia, Kleoniki

    2011-10-01

    To compare the diagnostic accuracy of digital radiography with that of digital subtraction radiography in the detection of simulated internal resorption cavities. Simulated internal resorption cavities of varying sizes were created using round burs in 18 single-rooted teeth with visible pulp chamber, which had been extracted from dentate dry mandibles and split into two halves in a mesio-distal direction. Resorption cavities were created in the buccal half of the root in the cervical, middle, and apical third. Digital radiographs were taken from three different horizontal view angles before and after the creation of the cavities. This process was followed by digital subtraction radiography to evaluate their detection. Seven experienced observers and all specialists in endodontics were asked to examine the digital and digital subtraction images for the presence of the cavities. The data were analyzed using SPSS 14. The overall sensitivity of digital subtraction radiography was superior to digital radiography and with statistically better results for all cavities regardless of their location (cervical, middle, apical third) (P < 0.05). The detection of the cavities was affected by the root third in which they were located. Cavities in the apical third were more easily detected compared with those in the middle or cervical third of the root. Small-sized lesions (0.5 mm, 0.6 mm) in the middle and apical third were more frequent and more easily detected using subtraction imaging. Digital subtraction radiography is superior to digital radiography for the detection and monitoring of the progress of internal root resorption. © 2011 John Wiley & Sons A/S.

  20. Imaging of the digital arteries: Digital subtraction angiography versus conventional angiography

    International Nuclear Information System (INIS)

    Menanteau, B.P.; Treutenaere, J.M.; Marcus, C.; Ladam, V.; Gausserand, F.

    1986-01-01

    The authors report their experience with the use of digital subtraction angiography (DSA) and conventional angiography of the hand. Of the 95 patients in the study group, 80 underwent conventional angiography and 15 underwent DSA. They analyzed the studies with regard to the type and amount of contrast agent used, the number of radiographs needed, and the diagnostic quality of the images. Conventional angiography often requires general anesthesia, magnification, and pharmaco-angiographic techniques to improve the image-based diagnosis. In comparison with conventional angiography, intraarterial DSA is characterized by improved contrast sensitivity and inferior spatial resolution. However, DSA provides images as acceptable as those of conventional angiography. Smaller catheters can be used, and the examination is performed under local anesthesia. The authors conclude that intraarterial DSA is now the technique of choice for examining patients with chronic ischemia of the hand

  1. Evaluation of left ventricular function using digital subtraction ventriculography

    International Nuclear Information System (INIS)

    Yiannikas, J.; Detrano, R.

    1986-01-01

    Digital subtraction ventriculography following injections of contrast via peripheral veins provides excellent images to assess left ventricular function. The images are essentially identical to those following DCV, but allow more uniform mixing of contrast in the left ventricular chamber. Furthermore, few, if any, cardiac arrhythmias occur, hence obviating difficulties that arise from DCV. The spatial resolution of the method is such that regional wall motion assessment of ventricular function is more accurate than that of other noninvasive imaging methods. The use of video-densitometry allows accurate assessment of left ventricular function even when the left ventricular cavity is nonsymmetrically deformed and aneurysmal. In the setting of the cardiac catheterization laboratory, digital ventriculography may provide a safer means of assessing left ventricular function when critical coronary or myocardial disease is present and allows multiple assessments of ventricular function during the same study. Although excellent correlations with standard ventriculography have been noted by all workers, significant discrepancies still exist in individual patients, particularly in the calculations of end diastolic volumes. In the authors experience and in those of most workers, the largest discrepancies existed in patients in whom suboptimal studies are included for analysis. The most frequent reason for the occasional suboptimal study as with all digital subtraction work is the misregistration that results from motion

  2. [Design and development of the DSA digital subtraction workstation].

    Science.gov (United States)

    Peng, Wen-Xian; Peng, Tian-Zhou; Xia, Shun-Ren; Jin, Guang-Bo

    2008-05-01

    According to the patient examination criterion and the demands of all related departments, the DSA digital subtraction workstation has been successfully designed and is introduced in this paper by analyzing the characteristic of video source of DSA which was manufactured by GE Company and has no DICOM standard interface. The workstation includes images-capturing gateway and post-processing software. With the developed workstation, all images from this early DSA equipment are transformed into DICOM format and then are shared in different machines.

  3. Real-time digital x-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.; Kruger, R.A.; Houk, T.L.

    1982-01-01

    A method of producing visible difference images derived from an x-ray image of an anatomical subject is described. X-rays are directed through the subject, and the image is converted into television fields comprising trains of analog video signals. The analog signals are converted into digital signals, which are then integrated over a predetermined time corresponding to several television fields. Difference video signals are produced by performing a subtraction between the ongoing video signals and the corresponding integrated signals, and are converted into visible television difference images representing changes in the x-ray image

  4. Digital image comparison by subtracting contextual transformations—percentile rank order differentiation

    Science.gov (United States)

    Wehde, M. E.

    1995-01-01

    The common method of digital image comparison by subtraction imposes various constraints on the image contents. Precise registration of images is required to assure proper evaluation of surface locations. The attribute being measured and the calibration and scaling of the sensor are also important to the validity and interpretability of the subtraction result. Influences of sensor gains and offsets complicate the subtraction process. The presence of any uniform systematic transformation component in one of two images to be compared distorts the subtraction results and requires analyst intervention to interpret or remove it. A new technique has been developed to overcome these constraints. Images to be compared are first transformed using the cumulative relative frequency as a transfer function. The transformed images represent the contextual relationship of each surface location with respect to all others within the image. The process of differentiating between the transformed images results in a percentile rank ordered difference. This process produces consistent terrain-change information even when the above requirements necessary for subtraction are relaxed. This technique may be valuable to an appropriately designed hierarchical terrain-monitoring methodology because it does not require human participation in the process.

  5. Statistically tuned Gaussian background subtraction technique for ...

    Indian Academy of Sciences (India)

    ground, small objects, moving background and multiple objects are considered for evaluation. The technique is statistically compared with frame differencing technique, temporal median method and mixture of Gaussian model and performance evaluation is done to check the effectiveness of the proposed technique after ...

  6. Real-time digital X-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.; Kruger, R.A.; Houk, T.L.

    1979-01-01

    A diagnostic anatomical X-ray apparatus comprising a converter and a television camera for converting an X-ray image of a subject into a series of television fields of video signals is described in detail. A digital memory system stores and integrates the video signals over a time interval corresponding to a plurality of successive television fields. The integrated video signals are recovered from storage and fed to a digital or analogue subtractor, the resulting output being displayed on a television monitor. Thus the display represents on-going changes in the anatomical X-ray image. In a modification, successive groups of fields are stored and integrated in three memories, cyclically, and subtractions are performed between successive pieces of integrated signals to provide a display of successive alterations in the X-ray image. For investigations of the heart, the integrating interval should be of the order of one cardiac cycle. (author)

  7. Digital subtraction angiography in 105 living renal transplant donors

    International Nuclear Information System (INIS)

    Suh, Ho Jong; Oh, Kyung Seung; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duck

    1989-01-01

    In order to analyze the number and length of the renal arteries and to evaluate abnormalities of the renal parenchyma and vessel, digital subtraction angiogram images of 105 potential renal donors (45 men and 60 women aged 17-66 years) were studied retrospectively. For the entire series, 31 donors had multiple renal arteries on one side (15 on the left, 11 on the right) and 5 donors on the both sides. 89 donors were family related either parents or siblings of recipients. The estimation of the length of the renal artery was based on the mean height of the second lumbar vertebral body (L2). The right renal artery is significant longer than on the left and measured more than the height of L2 vertebral body in 84 cases on the right and 60 cases on the left. Twenty two donors underwent right nephrectomy due to presence of multiple renal arteries on the left (N=14), proximal bifurcation of left main renal artery (N=3), and young females in reproductive age (N=5). Unexpected abnormalities found with angiogram were seen in 7 cases and they include renal artery stenosis (N=2), renal cysts (N=4) and focal infarction (N=1). In cases of the renal cysts and focal infarction, there were no serious complications related to the abnormalities. It is conclude that intra-arterial digital subtraction angiography is safe and efficient method to image renal anatomy of the potential renal donors

  8. Combined nuclear and digital subtraction contrast arthrography in painful knee prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Namasivayam, J.; Forrester, A. (Royal Infirmary, Glasgow (United Kingdom). Dept. of Radiology); Poon, F.W.; Cuthbert, G.F.; McKillop, J.H. (Royal Infirmary, Glasgow (United Kingdom). Dept. of Nuclear Medicine); Bryan, A.S.

    1992-06-01

    The evaluation of a painful knee prosthesis remains a difficult problem for both orthopaedic surgeons and radiologists. We have compared digital subtraction arthrography with nuclear-arthrography in 7 patients with a painful knee prosthesis. Three patients showed a loose tibial component, demonstrated by both digital subtraction and nuclear arthrography. All 3 underwent revision of their prosthesis. One patient had an equivocal digital subtraction arthrogram and negative nuclear arthrogram, while both studies were negative in the 3 remaining patients. Nuclear arthrography is a simple procedure and can provide useful additional information when combined with digital subtraction arthrography. (orig.).

  9. Using a digital signal processor as a data stream controller for digital subtraction angiography

    International Nuclear Information System (INIS)

    Meng, J.D.; Katz, J.E.

    1991-10-01

    High speed, flexibility, and good arithmetic abilities make digital signal processors (DSP) a good choice as input/output controllers for real time applications. The DSP can be made to pre-process data in real time to reduce data volume, to open early windows on what is being acquired and to implement local servo loops. We present an example of a DSP as an input/output controller for a digital subtraction angiographic imaging system. The DSP pre-processes the raw data, reducing data volume by a factor of two, and is potentially capable of producing real-time subtracted images for immediate display

  10. Digital subtraction CT angiography for the detection of posterior inferior cerebellar artery aneurysms: comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Guo Zhong; Luo, Song; Zhou, Chang Sheng; Zhang, Long Jiang; Lu, Guang Ming [Jinling Hospital, Medical School of Nanjing University, Department of Medical Imaging, Nanjing, Jiangsu (China)

    2017-09-15

    To evaluate the diagnostic accuracy of digital subtraction CT angiography (DS-CTA) in detecting posterior inferior cerebellar artery (PICA) aneurysms with digital subtraction angiography (DSA) as reference standard. A total of 115 patients, including 56 patients diagnosed with PICA aneurysms by CTA or DSA and 59 non-PICA-aneurysm patients were included in this retrospective study. All patients underwent DS-CTA and DSA. The site of PICA aneurysms and the pattern of haemorrhage were analysed. Sensitivity and specificity of DS-CTA without and with combining haemorrhage pattern in diagnosing PICA aneurysms were evaluated on a per patient and per aneurysm basis with DSA. Of 115 patients, 56 patients (48.7%) had 61 PICA aneurysms (size range, 1.1-13.5 mm; mean size, 4.9 ± 2.8 mm) on DSA. The sensitivity and specificity in depicting PICA aneurysms were 89.3% and 96.6% on a per patient basis and 90.2% and 93.4% on a per aneurysm basis, while the corresponding values were 94.6% and 96.6% on a per patient basis and 95.1% and 93.4% on a per aneurysm basis when combining with haemorrhage site. DS-CTA has a high sensitivity and specificity in detecting PICA aneurysms compared with DSA. It may be helpful for clinical diagnosis of PICA aneurysms to combine with haemorrhage sites. (orig.)

  11. Bi-Event Subtraction Technique at hadron colliders

    International Nuclear Information System (INIS)

    Dutta, Bhaskar; Kamon, Teruki; Kolev, Nikolay; Krislock, Abram

    2011-01-01

    We propose the Bi-Event Subtraction Technique (BEST) as a method of modeling and subtracting large portions of the combinatoric background during reconstruction of particle decay chains at hadron colliders. The combinatoric background arises when it is impossible to know experimentally which observed particles come from the decay chain of interest. The background shape can be modeled by combining observed particles from different collision events and be subtracted away, greatly reducing the overall background. This idea has been demonstrated in various experiments in the past. We generalize it by showing how to apply BEST multiple times in a row to fully reconstruct a cascade decay. We show the power of BEST with two simulated examples of its application towards reconstruction of the top quark and a supersymmetric decay chain at the Large Hadron Collider.

  12. Intravenous digital subtraction angiography in patients with cerebral ischaemia

    International Nuclear Information System (INIS)

    Mantoni, M.; Neergaard, K.

    1989-01-01

    Over a two-year period, 167 patients with symptoms of transient ischaemic attacks or suspected minor stroke underwent intravenous digital subtraction angiography (DSA) of the carotid arteries. There were no major complications. Ninety-six patients had abnormal angiograms, 60 normal studies, and in 11 patients (7%) the examination was not of diagnostic quality, mostly because of motion artifacts. In 86 patients no therapeutic consequences resulted from the DSA examination. Twenty-six patients were referred for vascular surgery, and 34 patients had either anticoagulation or aspirin therapy. In 10 patients a primary medical cause was found for their cerebral vascular symptoms. It is concluded that intravenous DSA of the carotid arteries in patients with transient ischaemic attack is a safe, diagnostically useful procedure, that can also be used on an outpatient basis. (orig.)

  13. Real-time digital x-ray subtraction imaging

    International Nuclear Information System (INIS)

    Mistretta, C.A.

    1982-01-01

    The invention provides a method of producing visible difference images derived from an X-ray image of an anatomical subject, comprising the steps of directing X-rays through the anatomical subject for producing an image, converting the image into television fields comprising trains of on-going video signals, digitally storing and integrating the on-going video signals over a time interval corresponding to several successive television fields and thereby producing stored and integrated video signals, recovering the video signals from storage and producing integrated video signals, producing video difference signals by performing a subtraction between the integrated video signals and the on-going video signals outside the time interval, and converting the difference signals into visible television difference images representing on-going changes in the X-ray image

  14. Image processing of images from peripheral-artery digital subtraction angiography (DSA) studies

    International Nuclear Information System (INIS)

    Wilson, D.L.; Tarbox, L.R.; Cist, D.B.; Faul, D.D.

    1988-01-01

    A system is being developed to test the possibility of doing peripheral, digital subtraction angiography (DSA) with a single contrast injection using a moving gantry system. Given repositioning errors that occur between the mask and contrast-containing images, factors affecting the success of subtractions following image registration have been investigated theoretically and experimentally. For a 1 mm gantry displacement, parallax and geometric image distortion (pin-cushion) both give subtraction errors following registration that are approximately 25% of the error resulting from no registration. Image processing techniques improve the subtractions. The geometric distortion effect is reduced using a piece-wise, 8 parameter unwarping method. Plots of image similarity measures versus pixel shift are well behaved and well fit by parabola, leading to the development of an iterative, automatic registration algorithm that uses parabolic prediction of the new minimum. The registration algorithm converges quickly (less than 1 second on a MicroVAX) and is relatively immune to the region of interest (ROI) selected

  15. Momentum-subtraction renormalization techniques in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Foda, O.

    1987-10-01

    Momentum-subtraction techniques, specifically BPHZ and Zimmermann's Normal Product algorithm, are introduced as useful tools in the study of quantum field theories in the presence of background fields. In a model of a self-interacting massive scalar field, conformally coupled to a general asymptotically-flat curved space-time with a trivial topology, momentum-subtractions are shown to respect invariance under general coordinate transformations. As an illustration, general expressions for the trace anomalies are derived, and checked by explicit evaluation of the purely gravitational contributions in the free field theory limit. Furthermore, the trace of the renormalized energy-momentum tensor is shown to vanish at the Gell-Mann Low eigenvalue as it should.

  16. Momentum-subtraction renormalization techniques in curved space-time

    International Nuclear Information System (INIS)

    Foda, O.

    1987-01-01

    Momentum-subtraction techniques, specifically BPHZ and Zimmermann's Normal Product algorithm, are introduced as useful tools in the study of quantum field theories in the presence of background fields. In a model of a self-interacting massive scalar field, conformally coupled to a general asymptotically-flat curved space-time with a trivial topology, momentum-subtractions are shown to respect invariance under general coordinate transformations. As an illustration, general expressions for the trace anomalies are derived, and checked by explicit evaluation of the purely gravitational contributions in the free field theory limit. Furthermore, the trace of the renormalized energy-momentum tensor is shown to vanish at the Gell-Mann Low eigenvalue as it should

  17. A case of aortitis syndrome diagnosed by digital subtraction angiography

    International Nuclear Information System (INIS)

    Tamaki, Atsushi; Sakai, Masashi; Yano, Kimio

    1984-01-01

    A 45-year-old female was admitted to our hospital with complaints of anemia, hypertension, and a dull, throbbing pain in the right side of the neck. On physical examination, a pulsating tumor in the right side of the neck and a ''to-and-fro'' murmur at the right 2nd intercostal space were noted. Laboratory tests revealed ESR 90 mm/hour and CRP 5+. Digital subtraction angiography (DSA) showed an aneurysm distal to the narrowing of the right common carotid artery, in addition to winding and narrowing of the right vertebral and the left common carotid arteries. These findings are typical of Type I aortitis syndrome. Aortogram showed aortic regurgitation (AR). Furthermore, we found the presence of HLA Bw52 and a conspicuous increase of tromboxane B 2 . Treatment involving a combination of prednisolone, azathioprine and estriol was effective, resulting in marked improvement of the patient's general condition as well as laboratory test results. In cases of aortitis syndrome combined with an aneurysm of a large artery and AR, direct opacification of the aorta with a catheter is occasionally hazardous and is difficult to perform repeatedly. DSA is useful in such circumstances because it can be performed repeatedly with little risk and it offers an image as clear as these obtained by direct injection of contrast medium in the aorta. (author)

  18. Radiation doses to patients from digital subtraction angiography

    International Nuclear Information System (INIS)

    Goni, H.; Tsalafoutas, I. A.; Tzortzis, G.; Pappas, P.; Bouzas, N.; Loulakas, J.; Georgiou, A.; Georgiou, E.; Yakoumakis, E. N.

    2005-01-01

    This investigation determined patient doses during digital subtraction angiography (DSA). Fluoroscopy time, dose-area product (DAP) and entrance surface air kerma (ESAK) were analysed from 263 DSA examinations, classified into seven categories: (1) abdominal aorta, iliac, femoral, popliteal and leg arteries; (2) abdominal aorta and super-selective DSA of renal arteries; (3) combination of (1) and (2); (4) super-selective DSA of common carotid and vertebral arteries, intracranial branches in face and profile projections; (5) super-selective DSA of hepatic, splenic, superior and inferior mesenteric arteries; (6) combination of (1) and (4); and (7) celiac trunk and branches. Median DAP values were 67.7, 92.9, 76.6, 53.6, 105.7, 76.1 and 2.6 Gy cm 2 , respectively. With the exception of one examination, ESAK values were below 2 Gy: the limit for erythema. Compared with published data, DAP values were within the range reported for (1) and (4), slightly larger for (2) and (5), whereas no references were identified for the remaining three categories. (authors)

  19. Robotic digital subtraction angiography systems within the hybrid operating room.

    Science.gov (United States)

    Murayama, Yuichi; Irie, Koreaki; Saguchi, Takayuki; Ishibashi, Toshihiro; Ebara, Masaki; Nagashima, Hiroyasu; Isoshima, Akira; Arakawa, Hideki; Takao, Hiroyuki; Ohashi, Hiroki; Joki, Tatsuhiro; Kato, Masataka; Tani, Satoshi; Ikeuchi, Satoshi; Abe, Toshiaki

    2011-05-01

    Fully equipped high-end digital subtraction angiography (DSA) within the operating room (OR) environment has emerged as a new trend in the fields of neurosurgery and vascular surgery. To describe initial clinical experience with a robotic DSA system in the hybrid OR. A newly designed robotic DSA system (Artis zeego; Siemens AG, Forchheim, Germany) was installed in the hybrid OR. The system consists of a multiaxis robotic C arm and surgical OR table. In addition to conventional neuroendovascular procedures, the system was used as an intraoperative imaging tool for various neurosurgical procedures such as aneurysm clipping and spine instrumentation. Five hundred one neurosurgical procedures were successfully conducted in the hybrid OR with the robotic DSA. During surgical procedures such as aneurysm clipping and arteriovenous fistula treatment, intraoperative 2-/3-dimensional angiography and C-arm-based computed tomographic images (DynaCT) were easily performed without moving the OR table. Newly developed virtual navigation software (syngo iGuide; Siemens AG) can be used in frameless navigation and in access to deep-seated intracranial lesions or needle placement. This newly developed robotic DSA system provides safe and precise treatment in the fields of endovascular treatment and neurosurgery.

  20. Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Ginai, A.Z. [Dept. of Radiology, Univ. Hospital Dijkzigt, Rotterdam (Netherlands); Biezen, F.C. van [Dept. of Orthopaedics, Univ. Hospital Dijkzigt and Erasmus Univ., Rotterdam (Netherlands); Kint, P.A.M. [Dept. of Radiology, Univ. Hospital Dijkzigt, Rotterdam (Netherlands); Oei, H.Y. [Dept. of Nuclear Medicine, Univ. Hospital Dijkzigt and Erasmus Univ., Rotterdam (Netherlands); Hop, W.C.J. [Dept. of Biostatistics, Univ. Hospital Dijkzigt and Erasmus Univ., Rotterdam (Netherlands)

    1996-05-01

    Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Digital subtraction arthrography was best for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs and scintigraphy. Digital subtraction arthrography was also the most important modality for predicting a loose femoral component, while the plain radiograph was of significant additional value and scintigraphy was of no additional value on multivariate analysis. (orig./MG)

  1. Digital subtraction arthrography in preoperative evaluation of painful total hip arthroplasty

    International Nuclear Information System (INIS)

    Ginai, A.Z.; Biezen, F.C. van; Kint, P.A.M.; Oei, H.Y.; Hop, W.C.J.

    1996-01-01

    Digital subtraction arthrograms, scintigrams and plain radiographs of 70 consecutive patients who underwent revision hip arthroplasty were scored individually and in masked fashion for the presence or absence of features indicating loosening of femoral and/or acetabular components. The operative findings acted as the gold standard. Digital subtraction arthrography was best for predicting a loose acetabular component, while no significant additional predictive value was found for plain radiographs and scintigraphy. Digital subtraction arthrography was also the most important modality for predicting a loose femoral component, while the plain radiograph was of significant additional value and scintigraphy was of no additional value on multivariate analysis. (orig./MG)

  2. Digital Subtraction Phonocardiography (DSP applied to the detection and characterization of heart murmurs

    Directory of Open Access Journals (Sweden)

    Ali Akbari Mohammad

    2011-12-01

    Full Text Available Abstract Background During the cardiac cycle, the heart normally produces repeatable physiological sounds. However, under pathologic conditions, such as with heart valve stenosis or a ventricular septal defect, blood flow turbulence leads to the production of additional sounds, called murmurs. Murmurs are random in nature, while the underlying heart sounds are not (being deterministic. Innovation We show that a new analytical technique, which we call Digital Subtraction Phonocardiography (DSP, can be used to separate the random murmur component of the phonocardiogram from the underlying deterministic heart sounds. Methods We digitally recorded the phonocardiogram from the anterior chest wall in 60 infants and adults using a high-speed USB interface and the program Gold Wave http://www.goldwave.com. The recordings included individuals with cardiac structural disease as well as recordings from normal individuals and from individuals with innocent heart murmurs. Digital Subtraction Analysis of the signal was performed using a custom computer program called Murmurgram. In essence, this program subtracts the recorded sound from two adjacent cardiac cycles to produce a difference signal, herein called a "murmurgram". Other software used included Spectrogram (Version 16, GoldWave (Version 5.55 as well as custom MATLAB code. Results Our preliminary data is presented as a series of eight cases. These cases show how advanced signal processing techniques can be used to separate heart sounds from murmurs. Note that these results are preliminary in that normal ranges for obtained test results have not yet been established. Conclusions Cardiac murmurs can be separated from underlying deterministic heart sounds using DSP. DSP has the potential to become a reliable and economical new diagnostic approach to screening for structural heart disease. However, DSP must be further evaluated in a large series of patients with well-characterized pathology to determine

  3. Mental Computation or Standard Algorithm? Children's Strategy Choices on Multi-Digit Subtractions

    Science.gov (United States)

    Torbeyns, Joke; Verschaffel, Lieven

    2016-01-01

    This study analyzed children's use of mental computation strategies and the standard algorithm on multi-digit subtractions. Fifty-eight Flemish 4th graders of varying mathematical achievement level were individually offered subtractions that either stimulated the use of mental computation strategies or the standard algorithm in one choice and two…

  4. Diagnosis of vertical root fractures in endodontically treated teeth utilising Digital Subtraction Radiography: A case series report.

    Science.gov (United States)

    Mikrogeorgis, Georgios; Eirinaki, Eleni; Kapralos, Vasileios; Koutroulis, Andreas; Lyroudia, Kleoniki; Pitas, Ioannis

    2017-12-11

    Vertical root fractures are commonly associated with root-filled teeth. Diagnosis is challenging because the clinical signs are not completely pathognomonic, and conventional periapical radiography is often unreliable. Digital subtraction radiography (DSR) is able to detect small radiographic changes between two successive radiographs by subtracting out consistent radiographic elements. Its use could possibly assist in the diagnostic procedure. Four cases are presented to demonstrate the potential use of DSR in the detection of vertical root fractures in endodontically treated teeth. After the digital subtractions had been carried out, a dark line in the body of the roots was distinguishable, raising the possibility of the presence of a vertical root fracture. The use of contrast enhancement and pseudocolouring techniques assisted with the diagnosis of vertical root fractures. DSR proved to be a useful diagnostic tool for the detection of vertical root fractures in these four clinical cases. © 2017 Australian Society of Endodontology Inc.

  5. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    International Nuclear Information System (INIS)

    Schueltke, E.; Fiedler, S.; Kelly, M.; Griebel, R.; Juurlink, B.; LeDuc, G.; Esteve, F.; Le Bas, J.-F.; Renier, M.; Nemoz, C.; Meguro, K.

    2005-01-01

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible

  6. The potential for neurovascular intravenous angiography using K-edge digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Schueltke, E. [University of Saskatchewan, Saskatoon, SK (Canada) and Walton Medical Centre, University of Liverpool (United Kingdom)]. E-mail: els433@duke.usask.ca; Fiedler, S. [EMBL, Hamburg (Germany); Kelly, M. [University of Saskatchewan, Saskatoon, SK (Canada); Griebel, R. [University of Saskatchewan, Saskatoon, SK (Canada); Juurlink, B. [University of Saskatchewan, Saskatoon, SK (Canada); LeDuc, G. [ESRF, Grenoble (France); Esteve, F. [INSERM U647-ESRF, Grenoble (France); Le Bas, J.-F. [INSERM U647-ESRF, Grenoble (France); Renier, M. [ESRF, Grenoble (France); Nemoz, C. [ESRF, Grenoble (France); Meguro, K. [University of Saskatchewan, Saskatoon, SK (Canada)

    2005-08-11

    Background: Catheterization of small-caliber blood vessels in the central nervous system can be extremely challenging. Alternatively, intravenous (i.v.) administration of contrast agent is minimally invasive and therefore carries a much lower risk for the patient. With conventional X-ray equipment, volumes of contrast agent that could be safely administered to the patient do not allow acquisition of high-quality images after i.v. injection, because the contrast bolus is extremely diluted by passage through the heart. However, synchrotron-based digital K-edge subtraction angiography does allow acquisition of high-quality images after i.v. administration of relatively small doses of contrast agent. Materials and methods: Eight adult male New Zealand rabbits were used for our experiments. Animals were submitted to both angiography with conventional X-ray equipment and synchrotron-based digital subtraction angiography. Results: With conventional X-ray equipment, no contrast was seen in either cerebral or spinal blood vessels after i.v. injection of iodinated contrast agent. However, using K-edge digital subtraction angiography, as little as 1 ml iodinated contrast agent, when administered as i.v. bolus, yielded images of small-caliber blood vessels in the central nervous system (both brain and spinal cord). Conclusions: If it would be possible to image blood vessels of the same diameter in the central nervous system of human patients, the synchrotron-based technique could yield high-quality images at a significantly lower risk for the patient than conventional X-ray imaging. Images could be acquired where catheterization of feeding blood vessels has proven impossible.

  7. Improved artifact rejection and isolation of compound action potentials by means of digital subtraction.

    Science.gov (United States)

    Kiss, I; Shizgal, P

    1989-12-01

    When recording compound action potentials (CAPs) elicited by stimulating near the recording site, it may prove difficult to distinguish the CAP from the shock artifact because of their overlap in time. This problem is compounded when a pair of stimulation pulses is delivered because the CAP elicited by the test pulse (T pulse) may be partially superimposed on the artifact and response elicited by the conditioning pulse (C pulse) as well as on the T pulse artifact. Methods based on digital subtraction were used to address these problems. A record was obtained with the C-T interval adjusted to be slightly less than the absolute refractory period so that the T pulse would fail to elicit a CAP. A record consisting of a C pulse artifact and response was subtracted from this record to yield a 'pure' shock artifact. In principle, subtracting this 'artifact-only' record from records obtained with single pulses removes the shock artifact and yields a 'pure' response. An extension of this method was used to isolate T pulse responses from the C pulse artifact, C pulse response, and T pulse artifact. These methods proved effective in improving the isolation of the CAPs of interest from other features of the raw records. Limitations of the techniques and their complementarity with other methods of artifact reduction are discussed.

  8. The reduction of motion artifacts in digital subtraction angiography by geometrical image transformation

    International Nuclear Information System (INIS)

    Fitzpatrick, J.M.; Pickens, D.R.; Mandava, V.R.; Grefenstette, J.J.

    1988-01-01

    In the diagnosis of arteriosclerosis, radio-opaque dye is injected into the interior of the arteries to make them visible. Because of its increased contrast sensitivity, digital subtraction angiography has the potential for providing diagnostic images of arteries with reduced dye volumes. In the conventional technique, a mask image, acquired before the introduction of the dye, is subtracted from the contrast image, acquired after the dye is introduced, to produce a difference image in which only the dye in the arteries is visible. The usefulness of this technique has been severely limited by the image degradation caused by patient motion during image acquisition. This motion produces artifacts in the difference image that obscure the arteries. One technique for dealing with the problem is to reduce the degradation by means of image registration. The registration is carried out by means of a geometrical transformation of the mask image before subtraction so that it is in registration with the contrast image. This paper describes a technique for determining an optimal transformation. The authors employ a one-to-one elastic mapping and the Jacobian of that mapping to produce a geometrical image transformation. They choose a parameterized class of such mappings and use a heuristic search algorithm to optimize the parameters to minimize the severity of the motion artifacts. To increase the speed of the optimization process they use a statistical image comparison technique that provides a quick approximate evaluation of each image transformation. They present the experimental results of the application of their registration system to mask-contrast pairs, for images acquired from a specially designed phantom, and for clinical images

  9. Evaluation of chronic periapical lesions by digital subtraction radiography by using Adobe Photoshop CS: a technical report.

    Science.gov (United States)

    Carvalho, Fabiola B; Gonçalves, Marcelo; Tanomaru-Filho, Mário

    2007-04-01

    The purpose of this study was to describe a new technique by using Adobe Photoshop CS (San Jose, CA) image-analysis software to evaluate the radiographic changes of chronic periapical lesions after root canal treatment by digital subtraction radiography. Thirteen upper anterior human teeth with pulp necrosis and radiographic image of chronic periapical lesion were endodontically treated and radiographed 0, 2, 4, and 6 months after root canal treatment by using a film holder. The radiographic films were automatically developed and digitized. The radiographic images taken 0, 2, 4, and 6 months after root canal therapy were submitted to digital subtraction in pairs (0 and 2 months, 2 and 4 months, and 4 and 6 months) choosing "image," "calculation," "subtract," and "new document" tools from Adobe Photoshop CS image-analysis software toolbar. The resulting images showed areas of periapical healing in all cases. According to this methodology, the healing or expansion of periapical lesions can be evaluated by means of digital subtraction radiography by using Adobe Photoshop CS software.

  10. Digital subtraction radiographic evaluation of the standardize periapical intraoral radiographs

    International Nuclear Information System (INIS)

    Cho, Bong Hae; Nah, Kyung Soo

    1993-01-01

    The geometrically standardized intraoral radiographs using 5 occlusal registration material were taken serially from immediate, 1 day, 2, 4, 8, 12 and 16 weeks after making the bite blocks. The qualities of those subtracted images were evaluated to check the degree of reproducibility of each impression material. The results were as follows: 1. The standard deviations of the grey scales of the overall subtracted images were 4.9 for Exaflex, 7.2 for Pattern resin, 9.0 for Tooth Shade Acrylic, 12.2 for XCP only, 14.8 for Impregum. 2. The standard deviation of the grey scales of the overall subtracted images were grossly related to those of the localized horizontal line of interest. 3. Exaflex which showed the best subtracted image quality had 15 cases of straight, 14 cases of wave, 1 case of canyon shape. Impregum which showed the worst subtracted image quality had 4 cases of straight, 8 cases of wave, 18 cases of canyon shape respectively.

  11. Comparison of Accuracy of Conventional Periapical Radiography and Direct Digital Subtractions Radiography with or without Image Enhancement in the Diagnosis of Density Changes

    Directory of Open Access Journals (Sweden)

    Tahmineh Razi

    2012-04-01

    Full Text Available Background and aims. In periapical radiographic technique, the changes will be visible only after considerable deposition or resorption while digital subtraction technique visualizes slight density changes. This study was aimed to compare visualization of density changes in conventional periapical radiographs and digital subtraction technique with or without image enhancement. Materials and methods. Three dry human mandibles with unspecified age and gender were selected. Conventional periapical and direct digital radiographs were taken from the anterior, and right and left posterior regions by step-wise placement of aluminum plates until the image of the plate was clearly visible. The radiographs taken with the direct digital technique were subtracted from the first radiograph using Photoshop software. Three observers evaluated the radiographs and the digital subtraction images with or without image enhancement. The density was recorded in each radiograph in which the image of the aluminum plate was completely visible. Results. In all mandibles, the differences in diagnosis of density changes between the conventional periapical radiographic technique and the direct digital subtraction radiographic technique with or without image enhancement were statistically significant irrespective of the region under study (p<0.001. There were no significant differences in the diagnosis of density changes in all the three mandibles in the left and right posterior regions between the two radiographic techniques. However, the differences in the anterior region were statistically significant (p<0.001. Conclusion. Direct digital subtraction radiographic technique with or without image enhancement is a more efficacious technique in exhibiting minor density changes compared to conventional periapical radiographic technique

  12. Intravenous digital subtraction angiography of the lower limbs combined with field movement (2-field DSA)

    International Nuclear Information System (INIS)

    Fritschy, P.; Terrier, F.

    1988-01-01

    We evaluated a bolus-chase technique designed to reduce the volume of contrast material and to shorten examination time during intravenous digital subtraction angiography (IV-DSA) of the lower limbs. With this technique, after a single injection of contrast material, two contiguous fields can be sequentially imaged (two-field DAS) using a step translated X-ray tube. 67 patients with peripheral vascular disease were studied. All examinations provided diagnostic information, so that in no instance additional intra-arterial injections were required. With the two-field DSA only 3.49 injections were needed in the average for five fields examined in each patient, resulting in a 30% reduction of contrast agent used. (orig.) [de

  13. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    International Nuclear Information System (INIS)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk; Choi, Yong Suk; Hwang, Eui Hwan

    2009-01-01

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 μm and the range of lesional area was 36.95-138.52 mm 2 . The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  14. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk [Department of Biomedical Engineering, School of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Choi, Yong Suk; Hwang, Eui Hwan [Department of Oral and Maxillofacial Radiology, Institute of Oral Biology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 {mu}m and the range of lesional area was 36.95-138.52 mm{sup 2}. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  15. Intraarterial digital subtraction angiography after plastic surgery by thin-needle puncture

    Energy Technology Data Exchange (ETDEWEB)

    Langer, M.; Fiegler, W.; Claussen, C.; Koehler, D.; Felix, R.; Hepp, W.

    1984-06-01

    Over the period of a year (1983), 44 intraarterial digital subtraction angiographies (DSA) via direct thin-needle puncture of a vascular bypass or following vascular graft were carried the rough. The only complication that occurred: paravasal injection, was clinically insignificant and could be avoided by a change in the puncture-technique. It was possible to carry through the investigation in out-patients. In all cases, diagnostically useful picture material for a possible surgical intervention was obtained. The pictures always were high-grade, independently of the patient's circulation time. Because this is a simple investigation and because of the small risk of complications, it has come to be regularly carried through as a routine in the authors' clinic. According to investigations carried through on the collective of patients of a vascular surgery department, occlusions or anastomotic aneurismus account for most of the angiological disorders.

  16. Intraarterial digital subtraction angiography after plastic surgery by thin-needle puncture

    International Nuclear Information System (INIS)

    Langer, M.; Fiegler, W.; Claussen, C.; Koehler, D.; Felix, R.; Hepp, W.

    1984-01-01

    Over the period of a year (1983), 44 intraarterial digital subtraction angiographies (DSA) via direct thin-needle puncture of a vascular bypass or following vascular graft were carried the rough. The only complication that occured: paravasal injection, was clinically insignificant and could be avoided by a change in the puncture-technique. It was possible to carry through the investigation in out-patients. In all cases, diagnostically useful picture material for a possible surgical intervention was obtained. The pictures always were high-grade, independently of the patient's circulation time. Because this is a simple investigation and because of the small risk of complications, it has come to be regularly carried through as a routine in the authors' clinic. According to investigations carried through on the collective of patients of a vascular surgery department, occlusions or anastomotic aneurismus account for most of the angiological disorders. (orig.) [de

  17. Evaluation of graft patency by intravenous digital subtraction angiography after vascular reconstruction

    International Nuclear Information System (INIS)

    Kuribayashi, Sachio; Ootaki, Makoto; Watabe, Tsuneya; Matsuyama, Seiya

    1985-01-01

    Intravenous digital subtraction angiography (IVDSA) was employed to evaluate graft patency after reconstructive vascular surgery in 45 cases with various vascular diseases. IVDSA offered equally valuable information about the patency of the graft, compared with conventional arteriography. In the peripheral vascular disease, IVDSA readily demonstrated patency or occlusion of the graft, even in the complex one, and the result of evaluation by IVDSA correlated well with that inferred by postoperative change in ankle pressure index measured by Doppler ultrasound technique. In the aortic disease, IVDSA was effective to rule out stenosis or leakage at the anastomotic site of the graft, and was also useful in the detection of the patency of the reconstructed inferior mesenteric artery after surgery for abdominal aortic aneurysm. The procedure in IVDSA is simple and safe, and it can be performed on an outpatient basis. IVDSA is a reliable and valuable approach in the evaluation of the graft patency after reconstructive vascular surgery. (author)

  18. Multi-section CT angiography compared with digital subtraction angiography in diagnosing major arterial hemorrhage in inflammatory pancreatic disease

    International Nuclear Information System (INIS)

    Hyare, Harpreet; Desigan, Sharmini; Nicholl, Helen; Guiney, Michael J.; Brookes, Jocelyn A.; Lees, William R.

    2006-01-01

    Purpose: Major arterial hemorrhage is an uncommon but serious complication of pancreatitis with high morbidity and mortality. Digital subtraction angiography (DSA) has long been the gold standard for the detection of a visceral artery pseudoaneurysm or for the site of active bleeding in patients with pancreatitis. Multi-section CT angiography is a minimally invasive technique which can provide high-resolution and high-contrast images of the arterial lumen and wall, with a much lower risk of complication and morbidity compared to DSA. The aim of this study was to determine the accuracy of multi-section CT angiography for the diagnosis of arterial complications of inflammatory pancreatitic disease. Materials and methods: A retrospective analysis of all patients undergoing visceral angiography for major bleeding as a complication of pancreatitis between 1998 and 2004 was performed. Twenty-nine studies in 25 patients (20 males, 5 females) with a mean age of 50.9 years (range 11-67 years) were identified where multi-section CT angiography was performed in the 24 h preceding the digital subtraction angiogram. Results: Digital subtraction angiography detected a pseudoaneurysm or contrast extravasation in 19 studies and no bleeding was demonstrated in 9 studies. CT angiography correctly identified the site and type of bleeding in 18 of the 19 positive studies. CT angiography detected extravasation of contrast in one study that was not demonstrated on digital subtraction angiography. The sensitivity and specificity for multi-section CT angiography for the detection of major arterial bleeding on a background of pancreatitis were 0.947 and 0.900, respectively. Conclusion: Multi-section CT angiography is a sensitive and accurate technique for the detection of major arterial hemorrhage in inflammatory pancreatic disease and should be considered as the first investigation in the management of these patients

  19. Temporal Subtraction of Digital Breast Tomosynthesis Images for Improved Mass Detection

    National Research Council Canada - National Science Library

    Li, Christina M

    2007-01-01

    .... The purpose of this project is to determine the feasibility of using temporal subtraction on DBT phantom images to allow for easier and earlier detection of breast cancer than with either technique alone...

  20. Videodensitometric ejection fraction from intravenous digital subtraction right ventriculograms: correlation with first pass radionuclide ejection fraction

    Energy Technology Data Exchange (ETDEWEB)

    Detrano, R.; MacIntyre, W.; Salcedo, E.E.; O' Donnell, J.; Underwood, D.A.; Simpfendorfer, C.; Go, R.T.; Butters, K.; Withrow, S.

    1985-06-01

    Thirty-one consecutive patients undergoing intravenous blurred mask digital subtraction right ventriculography were submitted to first pass radionuclide angiography. Second order mask resubtraction of end-diastolic and end-systolic right ventricular digital image frames was executed using preinjection end-diastolic and end-systolic frames to rid the digital subtraction images of mis-registration artifact. End-diastolic and end-systolic perimeters were drawn manually by two independent observers with a light pen. Ejection fractions calculated from the integrated videodensitometric counts within these perimeters correlated well with those derived from the first pass radionuclide right ventriculogram (r = 0.84) and the interobserver correlation was acceptable (r = 0.91). Interobserver differences occurred more frequently in patients with atrial fibrillation and in those whose tricuspid valve planes were difficult to discern on the digital subtraction right ventriculograms. These results suggest that videodensitometric analysis of digital subtraction right ventriculograms is an accurate method of determining right ventricular ejection fraction and may find wide clinical applicability.

  1. Preliminary study of lateral cerebral angiography with reverse rotation in the digital image registration and subtraction

    International Nuclear Information System (INIS)

    Shen Zhenglin; Liu Dongyang; Shen Zhenghai; Li Shuping; Zhang Ziyan; Wu Yongjuan; Liu Peijun

    2012-01-01

    Objective: Investigate the value and feasibility of image registration with reverse rotation in lateral cerebral DSA. Methods: (1) Experimental study: the target images were subtracted directly, and subtracted again after reverse rotation. Software of registration and subtraction with reverse rotation edited by the author utilizing Visual Basic. The function of the automatic angle detection by the software were evaluated to see whether it detected the angle of line. The subtraction function of DSA by the software was evaluated. (2) Clinical retrospective study: the untreated mask and target images of 15 patients with motion along vertical axis during lateral cerebral DSA were uploaded to the software. The target images were processed with and without the software to get two sets of images. (3) Evaluation: four experienced radiologists read and compared the two sets of the images,and graded their findings. Results: (1) The automatic detection by the software suggested that the target images should be rotated counterclockwise 1.3°. The subtraction result of the software was satisfactory. (2) In the 15 sets of images, there were only three sets of images deemed optimal after traditional subtraction. After reverse rotation, artifacts were significantly reduced and the image sharper. There were ten cases with significant artifacts after traditional subtraction, and those images were sharper and showed more peripheral vessels after reverse rotation. The traditional subtraction images of two sets could not be interpreted,the reverse rotation registration images reached the diagnostic quality. (3) Subjective evaluation: there were more information and less noise and distortion in the registration images with reverse rotation than in the traditional subtraction. But the image resolution decreased slightly after reverse rotation registration. Conclusion: The registration of digital angiography with reverse rotation can improve the image quality in lateral cerebral DSA

  2. Role of digital tomosynthesis and dual energy subtraction digital radiography in detecting pulmonary nodules

    International Nuclear Information System (INIS)

    Kumar, Sarvana G.; Garg, Mandeep Kumar; Khandelwal, Niranjan; Gupta, Pankaj; Gupta, Dheeraj; Aggarwal, Ashutosh Nath; Bansal, Subash Chand

    2015-01-01

    Highlights: • Accuracy of digital tomosynthesis for nodule detection is substantially higher. • Improvement in diagnostic accuracy is most pronounced for nodules <10 mm. • There is five times increase in radiation dose compared to DR. - Abstract: Objective: Digital tomosynthesis (DT) and dual-energy subtraction digital radiography (DES-DR) are known to perform better than conventional radiography in the detection of pulmonary nodules. Yet the comparative diagnostic performances of DT, DES-DR and digital radiography (DR) is not known. The present study compares the diagnostic performances of DT, DES-DR and DR in detecting pulmonary nodules. Subjects and methods: The institutional Review Board approved the study and informed written consent was obtained. Fifty-five patients (30 with pulmonary nodules, 25 with non-nodular focal chest pathology) were included in the study. DT and DES-DR were performed within14 days of MDCT. Composite images acquired at high kVp as part of DES-DR were used as DR images. Images were analyzed for presence of nodules and calcification in nodules. Interpretations were assigned confidence levels from 1 to 5 according to Five-Point rating scale. Areas under the receiver operating characteristic curves were compared using Z test. Results: A total of 110 (88 non-calcified, 22 calcified) nodules were identified on MDCT. For detection of nodules, DR showed cumulative sensitivity and specificity of 25.45% and 67.97%, respectively. DT showed a cumulative sensitivity and specificity of 60.9% and 85.07%, respectively. The performance was significantly better than DR (p < 0.003). DES-DR showed sensitivity and specificity of 27.75% and 82.64%, not statistically different from those of DR (p—0.92). In detection of calcification, there was no statistically significant difference between DT, DES-DR and DR. Conclusions: DT performs significantly better than DES-DR and DR at the cost of moderate increase in radiation dose

  3. Application of digital subtraction angiography in disease of large cardiac vessel

    International Nuclear Information System (INIS)

    Arisawa, Jun; Sone, Shusuke; Morimoto, Shizuo; Ikezoe, Junpei; Higashibara, Tokuro; Hanayama, Masayuki

    1983-01-01

    Digital subtraction angiography (DSA) was performed in 31 cases of disease of large cardiac vessel. DSA was useful for the diagnosis of aortic aneurysm and malformation of large vessels, follow-up after A-C bypass operation and Blalock's shunt operation for tetralogy of Fallot and as an adjuvant modality in cardiac catheterization. (Chiba, N.)

  4. Application of digital subtraction angiography in disease of large cardiac vessel

    Energy Technology Data Exchange (ETDEWEB)

    Arisawa, Jun; Sone, Shusuke; Morimoto, Shizuo; Ikezoe, Junpei; Higashibara, Tokuro; Hanayama, Masayuki

    1983-06-01

    Digital subtraction angiography (DSA) was performed in 31 cases of disease of large cardiac vessel. DSA was useful for the diagnosis of aortic aneurysm and malformation of large vessels, follow-up after A-C bypass operation and Blalock's shunt operation for tetralogy of Fallot and as an adjuvant modality in cardiac catheterization.

  5. A digital subtraction radiography based tool for periodontal bone resorption analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schiabel, Homero; Rodrigues, Eveline B., E-mail: homero@sc.usp.br [University of Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Dept. of Electrical Engineering; Rubira-Bullen, Izabel R.F. [University of Sao Paulo (USP), Bauru, SP (Brazil). Bauru Dentistry School

    2011-07-01

    The aim of this paper was to describe an aided diagnosis scheme for periodontal bone resorption so that the dentist can make an early diagnosis of the periodontal disease and establish the best treatment plan to increase the success of healing. Three ways of displaying the results are provided: qualitative, simple quantitative and colored-percentage quantitative views. A total of 72 pairs of in vitro radiographic images were used. The main procedure registers the images perspective projection aimed to align them in rotation and translation, and is followed by the application of a contrast correction technique. The results from the subtraction were evaluated firstly by the comparison between the actual and the digital sizes corresponding to the holes made by drills in phantoms. The mean error was 4.2%. The method was also applied to actual tooth radiographic images and could detect clearly the effect of treatment of periodontal diseases. It is dependent on the reproducibility of the process of radiographs acquisition and digitization, but the calculated mean error allows to conclude its better efficacy compared to usual procedures in this field. (author)

  6. A digital subtraction radiography based tool for periodontal bone resorption analysis

    International Nuclear Information System (INIS)

    Schiabel, Homero; Rodrigues, Eveline B.; Rubira-Bullen, Izabel R.F.

    2011-01-01

    The aim of this paper was to describe an aided diagnosis scheme for periodontal bone resorption so that the dentist can make an early diagnosis of the periodontal disease and establish the best treatment plan to increase the success of healing. Three ways of displaying the results are provided: qualitative, simple quantitative and colored-percentage quantitative views. A total of 72 pairs of in vitro radiographic images were used. The main procedure registers the images perspective projection aimed to align them in rotation and translation, and is followed by the application of a contrast correction technique. The results from the subtraction were evaluated firstly by the comparison between the actual and the digital sizes corresponding to the holes made by drills in phantoms. The mean error was 4.2%. The method was also applied to actual tooth radiographic images and could detect clearly the effect of treatment of periodontal diseases. It is dependent on the reproducibility of the process of radiographs acquisition and digitization, but the calculated mean error allows to conclude its better efficacy compared to usual procedures in this field. (author)

  7. New techniques in digital holography

    CERN Document Server

    Picart, Pascal

    2015-01-01

    A state of the art presentation of important advances in the field of digital holography, detailing advances related to fundamentals of digital holography, in-line holography applied to fluid mechanics, digital color holography, digital holographic microscopy, infrared holography, special techniques in full field vibrometry and inverse problems in digital holography

  8. Comparison of conventional panoramic radiography and panoramic digital subtraction radiography in detection of simulated lesions of mandibular condyle

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2008-12-01

    Full Text Available "n  "nBackground and Aim: Digital subtraction Radiography (DSR is a method of accurate assessing condylar head changes. several studies have been carried out in applying DSR in dentistry, however there is a few number of studies in efficacy of DSR method in assesment of condylar head changes, The aim of this study was to compare panoramic radiography and DSR detecting simulated lesions of the mandibular condyl. "nMaterials and Methods: this was a process reaserch study, in which two dry human skulls with no obvious temporomandibular joint pathology were used. Osteophytic lesions were simulated using three sizes of bone chips that were placed on the medial portion of anterior and superolateral aspects of the condyle. Osteolytic lesions were simulated making 1 and 2 mm holes using round burr in the central portion of anterior aspect and Lateral pole of the condyle. Panoramic radiographs were prepared with and without the lesions in place. These paired radiographs were digitized and digital- subtraction images of the original panoramic images were obtained. Eight observers evaluated 155 images of each modality for the presence or absence and the type of simulated lesions of the mandibular condyle. Sensitivity, specificity, reliability and measure of agreement were analyzed using kappa test and crossed tables and qualitative variables were assess by chi-square and fisher's Exact test. "nResults: Specificity of panoramic and DSR methods were 15.4% and 66.7% respectively. Sensitivity of panoramic and DSR methods were 61.1% and 80.6% for osteophytic lesions and 37.5% and 83.3% for Osteolytic lesions. The percentage of correct decisions made in DSR method was significantly more than conventional panoramic method (82.6% vs 41.9% (p<0.0001. "nConclusion: Based on the results of this study digital subtraction technique was significantly more accurate than the panoramic radiographs in detection of simulated lesions of the mandibular condyle.

  9. Experience with intravenous digital subtraction angiography following shunting in 4 cases of congenital heart diseases

    Energy Technology Data Exchange (ETDEWEB)

    Higashidate, Masafumi; Konno, Susumu; Sumitomo, Naokata; Ito, Sango; Kobayashi, Hiroshi

    1985-01-01

    Intravenous digital subtraction angiography (IV-DSA) was performed in two patients with Fallot's tetralogy who underwent Blalock-Taussing operation, a patient with coarctation of the aortic arch who underwent extra-anastomic bypass between the ascending aorta and the descending aorta, and a patient with stenosis of the tricuspid valve who underwent Fontan type operation (anastomosis between the right atrium and the pulmonary artery). The conventional cardiac angiography was also performed for the comparison with IV-DSA in all patients. IV-DSA revealed the thickness of the subclavian artery anastomosed by Blaloch-Taussing operation, but failed to determine the accurate thickness of the pulmonary artery required for PA-index for radical surgery in cases of Fallot's tetralogy. Bypass from the ascending aorta to the descending aorta was well visualized by IV-DSA because the heart did not overlap on the image. In cases of Fontan type operation, IV-DSA permitted the visualization of blood flow from the right atrium to the pulmonary artery and the shape of the pulmonary artery. It is concluded that IV-DSA is a less invasive, simple technique to evaluate patients' condition following shunting for congenital heart diseases, as compared to the conventional method. (Namekawa, K.).

  10. Experience with intravenous digital subtraction angiography following shunting in 4 cases of congenital heart diseases

    International Nuclear Information System (INIS)

    Higashidate, Masafumi; Konno, Susumu; Sumitomo, Naokata; Ito, Sango; Kobayashi, Hiroshi

    1985-01-01

    Intravenous digital subtraction angiography (IV-DSA) was performed in two patients with Fallot's tetralogy who underwent Blalock-Taussing operation, a patient with coarctation of the aortic arch who underwent extra-anastomic bypass between the ascending aorta and the descending aorta, and a patient with stenosis of the tricuspid valve who underwent Fontan type operation (anastomosis between the right atrium and the pulmonary artery). The conventional cardiac angiography was also performed for the comparison with IV-DSA in all patients. IV-DSA revealed the thickness of the subclavian artery anastomosed by Blaloch-Taussing operation, but failed to determine the accurate thickness of the pulmonary artery required for PA-index for radical surgery in cases of Fallot's tetralogy. Bypass from the ascending aorta to the descending aorta was well visualized by IV-DSA because the heart did not overlap on the image. In cases of Fontan type operation, IV-DSA permitted the visualization of blood flow from the right atrium to the pulmonary artery and the shape of the pulmonary artery. It is concluded that IV-DSA is a less invasive, simple technique to evaluate patients' condition following shunting for congenital heart diseases, as compared to the conventional method. (Namekawa, K.)

  11. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding

    International Nuclear Information System (INIS)

    Wildgruber, Moritz; Wrede, Christian E.; Zorger, Niels; Müller-Wille, René; Hamer, Okka W.; Zeman, Florian; Stroszczynski, Christian; Heiss, Peter

    2017-01-01

    Purpose: The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. Material and methods: The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. Results: 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%–99%) and 29% (7 of 24 patients; 95% CI 12%–49%) of patients, respectively (p < 0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%–63%) and 21% (5 of 24; 95% CI 7%–42%) of patients, respectively (p = 0.06). Conclusion: Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB.

  12. Computed tomography versus digital subtraction angiography for the diagnosis of obscure gastrointestinal bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Wildgruber, Moritz, E-mail: moritzwildgruber@ukmuenster.de [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Institut für klinische Radiologie, Universitätsklinikum Münster, D-48149 Münster (Germany); Wrede, Christian E. [Notfallzentrum, Helios Klinikum Berlin-Buch, D-13125 Berlin (Germany); Zorger, Niels [Institut für Radiologie, Neuroradiologie und Nuklearmedizin, Krankenhaus Barmherzige Brüder, D-93049 Regensburg (Germany); Müller-Wille, René; Hamer, Okka W. [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Zeman, Florian [Zentrum für Klinische Studien, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany); Stroszczynski, Christian; Heiss, Peter [Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, D-93053 Regensburg (Germany)

    2017-03-15

    Purpose: The diagnostic yield of computed tomography angiography (CTA) compared to digital subtraction angiography (DSA) for major obscure gastrointestinal bleeding (OGIB) is not known. Aim of the study was to prospectively evaluate the diagnostic yield of CTA versus DSA for the diagnosis of major OGIB. Material and methods: The institutional review board approved the study and informed consent was obtained from each patient. Patients with major OGIB were prospectively enrolled to undergo both CTA and DSA. Two blinded radiologists each reviewed the CTA and DSA images retrospectively and independently. Contrast material extravasation into the gastrointestinal lumen was considered diagnostic for active bleeding. Primary end point of the study was the diagnostic yield, defined as the frequency a technique identified an active bleeding or a potential bleeding lesion. The diagnostic yield of CTA and DSA were compared by McNemar's test. Results: 24 consecutive patients (11 men; median age 64 years) were included. CTA and DSA identified an active bleeding or a potential bleeding lesion in 92% (22 of 24 patients; 95% CI 72%–99%) and 29% (7 of 24 patients; 95% CI 12%–49%) of patients, respectively (p < 0.001). CTA and DSA identified an active bleeding in 42% (10 of 24; 95% CI 22%–63%) and 21% (5 of 24; 95% CI 7%–42%) of patients, respectively (p = 0.06). Conclusion: Due to the lower invasiveness and higher diagnostic yield CTA should be favored over DSA for the diagnosis of major OGIB.

  13. Normal anatomy and variations in the confluence of sinuses using digital subtraction angiography.

    Science.gov (United States)

    Cheng, Yaqin; Li, William A; Fan, Xingjuan; Li, Xiaohua; Chen, Jian; Wu, Yan; Meng, Ran; Ji, Xunming

    2017-06-01

    The configuration of the confluence of sinuses differs not only between individuals, but also between the two brain hemispheres, making the anatomical classification of this region difficult. In this study, we evaluated the anatomy of the confluence of sinuses and ascertained the accuracy and usefulness of digital subtraction angiography (DSA) in the evaluation of cerebral veins. Bilateral carotid and vertebral artery angiographies were performed in 500 adult patients to evaluate the anatomy of the confluence of sinuses and contributory venous sinuses. We appraised the anatomy of the sinuses adjacent to the confluence, the lateralization of venous draining into the transverse sinuses (TSs), the communications between the TSs, and the presentation of the occipital sinus (OS). Based on the anatomical descriptions of Osborn's Brain (Diagnostic Cerebral Angiography, 2nd edition), we delineated 10 different configurations of the confluence of sinuses that showed connections among the superior sagittal sinus, the straight sinus, and the left and right TSs. Right side dominant transverse sinus accounted for 49% of the cases. Direct communication between the TSs accounted for 46.4% of the cases. Indirect communication accounted for 51.6% of the case, and absence of communication between the left and the right TS accounted for 2%. Lastly, the presence of OS was observed in 6% of the cases. DSA promises to be an effective technique for studying the anatomy and normal variations of the confluence of sinuses, providing useful information for the diagnosis of cerebral venous diseases, and ensuring safer surgical procedures.

  14. Value of infusion-DSA (Digital Subtraction Angiography) in diagnosis of primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Kwon, Jeong Mi; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Chun, Byung Hee; Joh, Young Duk

    1991-01-01

    In order to evaluate diagnostic effectiveness of the infusion-study, the authors prospectively evaluated hepatic digital subtraction angiography of bolus and infusion studies in 71 patients with hepatocellular carcinoma. In contrast to Bolus-DSA, which involves a 2 second injection of 10cc of contrast medium, the Infusion-DSA uses a protracted (10sec) injection, a lower injection rate, and larger total dose of contrast medium (20cc). The information yield of arterial and capillary phases of Infusion-DSA was compared with that of Bolus-DSA and graded as 'improved(+)', 'equivalent( ± )', or 'poor(-)'. Also, the contribution of Infusion-DSA to the diagnosis was classified into one of five in a graded system. In 29 hepatocellular patients, the Infusion-DSA was helpful in detecting daughter nodules, fibrous capsule and arteriovenous shunt. Infusion-DSA is a useful complementary technique in the diagnosis of hepatocellular carcinoma and was also helpful in determining the selection of the therapeutic modality of hepatocellular carcinoma

  15. DIAGNOSTIC ACCURACY OF MAGNETIC RESONANCE ANGIOGRAPHY FOR UNRUPTURED CEREBRAL ANEURYSMS IN CORRELATION WITH DIGITAL SUBTRACTION ANGIOGRAPHY

    Directory of Open Access Journals (Sweden)

    Aleksandra Aracki-Trenkić

    2015-09-01

    Full Text Available Intracranial aneurysm is a focal, abnormal dilation of an artery of the brain. Magnetic resonance angiography (MRA is a non-invasive technique for vascular imaging and is thus widely used for screening for intracranial vascular lesions. The aim of the study was to show the diagnostic accuracy of 3D Time-of-Flight (3D TOF MRA in the detection of unruptured cerebral aneurysms with the use of digital subtraction angiography (DSA as the gold standard. A total of 2.612 consecutive patients underwent 3DTOF MRA. It showed unruptured aneurysms in 94 (3.6% patients. They included 68 women and 26 men ranging in age from 29 to 76 years (mean, 52.5 years. Twenty-six of them, 20 women and 6 men, underwent DSA. The Mann-Whitney U test was used for the correlation of size. Fisher’s test was used for the correlation of location. The statistical level of significance was set at p0.05 of aneurysms between TOF MRA and DSA. MRA is an accurate and non-invasive method for diagnosis of unruptured intracranial aneurysms. The results of study show the compatibility of MRA findings, the location and the size of an aneurysm in comparison with the “gold standard” – cerebral DSA.

  16. Intraarterial digital subtraction angiography in bronchogenic carcinoma treated with bronchial artery infusion

    International Nuclear Information System (INIS)

    Gao-Jun Teng; Xi-Lei Chai; Guang-Ru Gao; Cheng-Fong Chu; Xian-Guang Zhou; Zhu-Yi Zhang; Ru-Li Xiang

    1991-01-01

    Intra-arterial digital subtraction angiography (IADSA) has been used with advantage for control of the results of bronchial artery infusion of drugs for primarily unresectable bronchogenic carcinoma. The IADSA has been performed as road mapping prior to therapy. Drug treatment has been performed with 4 different regimes, depending on tumour type. Debulking and in some cases complete healing are the results, which are superior to other reported treatments. (author). 7 refs.; 4 figs.; 3 tabs

  17. Deep vein thrombosis of the upper extremity: intra- and interobserver study of digital subtraction venography

    Energy Technology Data Exchange (ETDEWEB)

    Baarslag, Henk J.; Delden, Otto M. van; Bakker, Ad J.; Reekers, Jim A. [Department of Radiology, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Beek, Edwin J.R. van [Department of Radiology, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands); Section of Academic Radiology, Floor C, Royal Hallamshire Hospital, Glossop Road, Sheffield S10 2JF (United Kingdom); Tijssen, Jan G.P. [Department of Cardiology, Academic Medical Center, Meibergdreef 9, 1105 AZ Amsterdam (Netherlands)

    2003-02-01

    Our objective was to assess the inter-observer and intra-observer agreement in the interpretation of digital subtraction venography (DSV) in patients with suspected deep vein thrombosis of the upper extremity (DVTUE). Prospectively, 62 consecutive DSV studies in 54 patients with clinically suspected DVTUE were included. Hard copies were presented without demographic data or original report. All venograms were read twice, at 3-month intervals, by an interventional vascular radiologist (observer 1) and an experienced general radiologist (observer 2). Consensus reading took place in the presence of a third experienced interventional radiologist. Inter-observer and intra-observer agreement were assessed using kappa statistics. Initial reading in 62 venograms showed an inter-observer agreement of 71% (kappa 0.48). The inter-observer agreement of the second reading was 83% (kappa 0.71). The agreement with the consensus report ranged from 76 to 94%. The intra-observer agreement for the first and second observer was 94% (kappa 0.89) and 76% (kappa 0.56), respectively (p<0.01). Digital subtraction venography has moderate to excellent intra- and inter-observer agreement, suggesting that digital subtraction venography is reliable for the diagnosis of DVTUE. (orig.)

  18. Digital subtraction radiography evaluation of longitudinal bone density changes around immediate loading implants: a pilot study.

    Science.gov (United States)

    Carneiro, L S; da Cunha, H A; Leles, C R; Mendonça, E F

    2012-03-01

    The aim of this study was to assess longitudinal quantitative changes in bone density around different implant loading protocols and implant surfaces measured by digital subtraction radiography (DSR). 12 patients received bilateral homologous standard and TiUnite® (Nobel Biocare, Kloten, Switzerland) single-tooth implants under 2 implant-loading protocols: immediate loading (8 patients, 16 implants, 12 maxillary) and conventional loading (4 patients, 8 implants, 4 maxillary). Standardized periapical radiographs were taken immediately after implant placement (baseline image) and at the 3-month, 6-month and 12-month follow ups. Radiographic images were digitized and submitted to digital subtraction using the DSR system® (Electro Medical System, Nyon, Switzerland), resulting in three subtracted images. Quantitative analysis of bone density was performed using Image Tool® software (University of Texas Health Science Centre, San Antonio, TX) to assess pixel value changes in five areas around the implants (crestal, subcrestal, medial third, apical-lateral and apical). Repeated-measures analysis of variance showed that grey levels were significantly influenced by follow-up time and implant-loading protocol. A linear increase in grey levels was found for immediate loading (IML) implants and a significant decrease in grey levels was observed in the 12-month follow up for conventional loading implants. No effect of implant surface treatment was observed. In conclusion, IML protocol induced mineral bone gain around single-tooth implants after the first year under function for cases with favourable bone conditions.

  19. Dissociated brain organization for two-digit addition and subtraction: an fMRI investigation.

    Science.gov (United States)

    Yi-Rong, Ni; Si-Yun, Shu; Zhou-Yi, Guo; Si-Run, Liu; Yun, Bao; Song-Hao, Liu; Chan, Wood Yee

    2011-11-25

    The present study compared the patterns of brain activation elicited by two-digit addition and subtraction problems. Thirty-two Chinese undergraduates of the same educational background and of similar age were asked to assess whether arithmetic operations were true or false during functional magnetic resonance imaging. Results showed that both complex addition and subtraction were supported by the broad neural system that involved regions within the inferior parietal lobule, the precuneus, and the inferior occipital gyrus, as well as some subcortical structures. Nevertheless, complex problems involving addition elicited more activation mainly in the bilateral medial frontal gyrus, whereas problems involving subtraction had more activation in the precentral gyrus and the thalamus in the right hemisphere, as well as the inferior parietal lobule in the left hemisphere. This pattern of dissociated activation suggests that partially separate neuronal networks might support these different operations. It also suggests that complex addition has a greater reliance on the fronto-parietal cortical circuit and subtraction on the parieto-subcortical circuit. Copyright © 2011 Elsevier Inc. All rights reserved.

  20. Comparison of CT angiography and digital subtraction angiography in the evaluation of intracranial aneurysmal neck

    International Nuclear Information System (INIS)

    Kim, Yoo Kyung; Baik, Seung Kug; Shin, Mi Jeong; Choi, Han Yong

    2001-01-01

    To compare the usefulness of three-dimensional multislice CT angiography(CTA) and digital subtraction angiography (DSA) in the evaluation of intracranial aneurysmal neck. Nineteen patients with intracranial aneurysm (23 cases) underwent DSA and subsequent CTA. Using a multislice CT scanner and the SSD(shaded surface display) technique, clipping, cutting and the MPR technique, three-dimensional images were obtained. These were (a) external, (b) internal, from the direction of the parent artery, (c) internal, from the direction of the aneurysmal dome, and (d) an aneurysmal cutting image. The CTA findings were retrospectively compared with the DSA images. Twenty aneurysms were small and three were large. In eleven cases aneurysm neck was small, in nine it was wide, and in three it was relatively wide. For aneurysmal neck evaluation, CTA was superior to DSA in six of nine wide-neck aneurysms and all three large-sized wide-neck aneurysms. In small neck aneurysms 8 of 11 cases and in relatively wide neck all 3 cases showed similarly good images by both modalities. Of the 23 cases demonstrated by four different images, 14 cases showed the best image in internal image from parent artery direction and 6 cases showed similarly good image in both aneurysmal cutting image and internal image from parent artery direction. In the evaluation of wide neck aneurysms, 7 of 9 cases showed the best image at internal image from parent artery direction, compared with other three different images. In two cases of aneurysms, calcification was visible in the aneurysmal wall, so it was difficult to evaluate the aneurysmal neck. CTA was superior to DSA in the evaluating the intracranial aneurysmal neck. CTA maybe an additional available modality to evaluate the aneurysmal neck which is difficult to detect by the DSA. And the information of intracranial aneurysmal neck through CTA will be of value in surgical and endovascular treatment

  1. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: comparison with digital subtraction angiography.

    Science.gov (United States)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-10-01

    To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect.

  2. Bone marrow edema pattern identification in patients with lytic bone lesions using digital subtraction angiography-like bone subtraction on large-area detector computed tomography.

    Science.gov (United States)

    Gondim Teixeira, Pedro Augusto; Hossu, Gabriela; Lecocq, Sophie; Razeto, Marco; Louis, Matthias; Blum, Alain

    2014-03-01

    The objective of this study was to evaluate the performance of digital subtraction angiography (DSA)-like bone subtraction with 2 different registration methods for the identification of bone marrow edema pattern (BMEP) in patients with lytic bone lesions, using magnetic resonance imaging as the criterion standard. Fifty-five patients with a lytic bone lesion were included in this prospective study with approval from the ethics committee. All patients underwent magnetic resonance imaging and low-dose computed tomographic (CT) perfusion after signing an informed consent. Two CT volumes were used for bone subtraction, which was performed with 2 different algorithms (rigid and nonrigid). Enhancement at the nonlytic bone marrow was considered as a sign of BMEP. Two readers evaluated the images blindly. The presence of BMEP on bone-subtracted CT images was evaluated subjectively and quantitatively. Image quality was assessed. Magnetic resonance imaging was used as the criterion standard. Using a rigid registration method, the sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CT with DSA-like bone subtraction BMEP was 77%, 100%, 100%, 68%, and 85%, respectively. The interobserver agreement was good (κ, 0.782). Image quality was better using a nonrigid registration. With this algorithm, artifacts interfered with image interpretation in only 5% of cases. However, there was a noticeable drop in sensitivity and negative predictive value when a nonrigid algorithm was used: 56% and 52%, respectively. The interobserver agreement was average with a nonrigid subtraction algorithm. Computed tomography with DSA-like bone subtraction is sensitive and highly specific for the identification of BMEP associated with lytic bone lesions. Rigid registering should be preferred, but nonrigid algorithms can be used as a second option when artifacts interfere with image interpretation.

  3. Reproducibility of and file format effect on digital subtraction radiography of simulated external root resorptions.

    Science.gov (United States)

    Gegler, A; Mahl, Cew; Fontanella, V

    2006-01-01

    To evaluate, in simulated external root resorptions (ERR), two factors that may affect results of digital subtraction radiography (DSR): (1) intraobserver and interobserver reproducibility and (2) effects of digital file formats (TIFF, BMP and JPEG) on the estimation of mineral loss. Eleven incisors were radiographed three times (NR, no resorption; SR, small--#1/4 round bur; and LR, large--#2 round bur) on standardized projections. The resulting images were reproduced and saved as TIFF, JPEG and BMP file formats. The pairs of TIFF images (NR x SR and NR x LR) were subtracted three times at 1 week intervals by three observers. One observer subtracted pairs of images (NR x SR and NR x LR) for all file formats. For each subtraction the resorption area was selected and mean pixel density values were calculated. Analysis of variance (ANOVA) (P = 0.05) showed no statistical differences for intraobserver and interobserver values. Mean pixel density values were: observer A, 121.60 +/- 2.56 (NR x SR) and 111.84 +/- 4.04 (NR x LR); observer B, 121.86 +/- 2.50 (NR x SR) and 110.92 +/- 3.36 (NR x LR); and observer C, 121.70 +/- 2.39 (NR x SR) and 111.10 +/- 2.67 (NR x LR). Also, no statistical differences were found between file formats for LR (TIFF, 110.88 +/- 2.79; JPEG, 111.35 +/- 3.35; BMP, 111.00 +/- 2.70) and for SR between TIFF (121.30 +/- 2.34) and JPEG (120.46 +/- 1.51) or BMP (121.67 +/- 2.18) file formats. Differences were found between the JPEG and BMP groups. DSR is reproducible in simulated ERR, and JPEG or BMP file formats do not affect results.

  4. Accuracy of digital subtraction radiography in combination with a contrast media in assessment of proximal caries depth

    Directory of Open Access Journals (Sweden)

    Farzad Esmaeili

    2008-07-01

    Full Text Available Background and aims. Radiography is used to diagnose the demineralization process and carious lesions; however, conventional radiography and direct digital images do not show these lesions when the amount of demineralization is less than 40%. Digital subtraction radiography has recently been used to improve the diagnostic quality of these lesions. The purpose of this study was to compare the caries depth estimated by digital subtraction radiography in combination with barium sulfate in diagnosing proximal dental caries with histopathologic evaluation. Materials and methods. In this study 30 molars and premolars (24 demineralized lesions with cavity, 8 without cavity were studied. Direct digital images were taken (kVp: 68, mA: 8; t: 0.12 for premolars and t: 0.16 for molars whereas the position of X-ray tube and CCD receptor and teeth was fixed. To prepare the second images 135 gr/L barium sulfate was used. The images obtained with the same exposure and geometry and then subtracted. The depth of the lesions in direct digital and subtracted images were assessed and compared with the depth measured in histopathologic assessments. Results. The mean depths (± SD of the lesions were 1.80 ± 0.77 mm in direct digital radiography, 2.32 ± 0.76 mm in subtracted images after barium sulfate treatment, and 2.51 ± 0.43 mm in histopathologic sections. The statistical difference between direct digital radiography and the other methods was significant (P < 0.05. However, the differences were not statistically significant between subtracted images and histopathologic sections. The average intra-class correlation coefficient was 0.7241 (CI: 95%. Conclusion. The present study has demonstrated that digital subtraction radiography images have the potential to measure the depth of proximal caries with no significant difference with histopathologic evaluation.

  5. Digital synchronization and communication techniques

    Science.gov (United States)

    Lindsey, William C.

    1992-01-01

    Information on digital synchronization and communication techniques is given in viewgraph form. Topics covered include phase shift keying, modems, characteristics of open loop digital synchronizers, an open loop phase and frequency estimator, and a digital receiver structure using an open loop estimator in a decision directed architecture.

  6. Digital fluoroscopy: Technique and applications for evaluating left ventricular function

    International Nuclear Information System (INIS)

    Higgins, C.B.; Norris, S.L.; Gerber, K.H.; Ashburn, W.L.; Slutsky, R.A.

    1985-01-01

    Central cardiovascular dynamics can be studied without cardiac catheterization by digital processing of fluoroscopic images of the heart obtained after central intravenous injection of contrast media. While digital subtraction angiography has been used for studying peripheral vasculature for several years, it is only recently that this technique has been applied for assessing cardiac morphology and physiology. The conversion of fluoroscopic x-ray data into a digital form has an added advantage for the study of the central cardiovascular system since it not only permits contrast enhancement of the images but also facilitates quantitative and functional analysis of the x-ray data. The several applications described in this chapter suggest that digital subtraction cardiovascular angiography will prove to be a powerful tool for studying cardiovascular physiology in animals and for evaluating heart disease in patients

  7. Mycotic aneurysms in intravenous drug abusers: the utility of intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Shetty, P.C.; Krasicky, G.A.; Sharma, R.P.; Vemuri, B.R.; Burke, M.M.

    1985-01-01

    Two-hundred thirteen intravenous digital subtraction angiographic (DSA) examinations were performed on 195 intravenous drug abusers to rule out the possibility of a mycotic aneurysm in a groin, neck, or upper extremity infection. Twenty-three surgically proved cases of mycotic aneurysm were correctly identified with no false positive results. In addition, six cases of major venous occlusion were documented. The authors present the results of their experience and conclude that DSA is an effective and cost-efficient method of examining this high risk patient population

  8. Assessment of maximal myocardial perfusion by ECG-triggered digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Pijls, N.H.J.; Uijen, G.J.H.; Werf, T. van der (Katholieke Univ. Nijmegen (Netherlands). Cardiology Dept.)

    1991-01-01

    Early studies about calculation of coronary blood flow by analysis of contrast agent passage on the coronary arteriogram were reported more than 2 decades ago by Rutishauser et al. and Smith et al. Thereafter is was shown that visualization of contrast passage through the myocardium could be enhanced by ECG-triggered digital subtraction imaging and it was suggested that myocardial flow could be calculated by studying the temporal changes in contrast intensity in a myocardial region of interest (ROI) as a function of time: the time density curve (TDC). (orig./GDG).

  9. Advantages and limitation of intra-arterial digital subtraction angiography (i.a. DSA)

    International Nuclear Information System (INIS)

    Beduhn, D.

    1986-01-01

    Among 3000 digital subtraction angiographies which have been performed in our institute, 850 patients have been examined intraarterially. The advantage of i.a. DSA is due to the excellent demonstration of vessels in survey angiograms by small amounts of contrast medium (10-20 ml in the aorta), without risk of selective catheterisation into the neck vessels, the saving of expensive film series, the short duration of vessel examinations and the small complication rate. i.a. DSA can be carried out on outpatients also, using the 4/5 F-catheter, which saves hospital charges. Impressive examples show the advantages of i.a. DSA. (orig.) [de

  10. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    International Nuclear Information System (INIS)

    Sharma, Madhurima; Sandhu, Manavjit Singh; Gorsi, Ujjwal; Gupta, Dheeraj; Khandelwal, Niranjan

    2015-01-01

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to compare them with digital radiography (DR). Materials and methods: This prospective study was approved by our institutional review committee. DTS and DES-DR were performed in 62 patients with active pulmonary TB within one week of multidetector computed tomography (MDCT) study. Findings of active pulmonary TB, that is consolidation, cavitation and nodules were noted on digital radiography (DR), DTS and DES-DR in all patients. Sensitivity, specificity, positive and negative predictive values of all 3 modalities was calculated with MDCT as reference standard. In addition presence of centrilobular nodules was also noted on DTS. Results: Our study comprised of 62 patients (33 males, 29 females with age range 18–82 years). Sensitivity and specificity of DTS for detection of nodules and cavitation was better than DR and DES-DR. Sensitivity and specificity of DTS for detection of consolidation was comparable to DR and DES-DR. DES-DR performed better than DR in detection of nodules and cavitation. DTS was also able to detect centrilobular nodules with sensitivity and specificity of 57.4% and 86.5% respectively. Conclusion: DTS and DES-DR perform better

  11. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Madhurima, E-mail: madhurimashrm88@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Sandhu, Manavjit Singh, E-mail: manavjitsandhu@yahoo.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gorsi, Ujjwal, E-mail: ujjwalgorsi@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gupta, Dheeraj, E-mail: dheeraj1910@gmail.com [Department of Pulmonary Medicine, PGIMER, Chandigarh 160012 (India); Khandelwal, Niranjan, E-mail: khandelwaln@hotmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India)

    2015-09-15

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to compare them with digital radiography (DR). Materials and methods: This prospective study was approved by our institutional review committee. DTS and DES-DR were performed in 62 patients with active pulmonary TB within one week of multidetector computed tomography (MDCT) study. Findings of active pulmonary TB, that is consolidation, cavitation and nodules were noted on digital radiography (DR), DTS and DES-DR in all patients. Sensitivity, specificity, positive and negative predictive values of all 3 modalities was calculated with MDCT as reference standard. In addition presence of centrilobular nodules was also noted on DTS. Results: Our study comprised of 62 patients (33 males, 29 females with age range 18–82 years). Sensitivity and specificity of DTS for detection of nodules and cavitation was better than DR and DES-DR. Sensitivity and specificity of DTS for detection of consolidation was comparable to DR and DES-DR. DES-DR performed better than DR in detection of nodules and cavitation. DTS was also able to detect centrilobular nodules with sensitivity and specificity of 57.4% and 86.5% respectively. Conclusion: DTS and DES-DR perform better

  12. Advanced techniques for digital angiography of the heart

    International Nuclear Information System (INIS)

    Hoehne, K.H.; Obermoeller, U.; Riemer, M.; Witte, G.

    1987-01-01

    Digital angiography is widely considered as being simply a method in which images taken at different times are subtracted from each other. This paper presents some techniques which are performed in the frequency domain after the application of the Fourier Transform. Nonselective bypass angiograms and intravenous ventriculograms are taken as examples to show that simple procedures utilizing these techniques exhibit the advantages of improved signal to noise ratio in the subtraction images, reduction of motion artefacts, easy application of phase-synchronous subtraction, integration and quantitative visualization of blood propagation. Furthermore it is shown that the storage of the angiographic image sequence as Fourier-coefficients leads to data compression and convenient data access in an image database. (Auth.)

  13. Evaluation of Bone Change by Digital Subtraction Radiography After Implantation of Tooth ash-plaster Mixture

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Duk; Kim, Kwang Won; Cho, Young Gon; Kim, Dong Kie; Choi, Eui Hwan [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Chosun University and Oral Biology Research Center, Kwangju (Korea, Republic of)

    1999-08-15

    To assess the methods for the clinical evaluation of the longitudinal bone changes after implantation of tooth ash-plaster mixture into the defect area of human jaws. Tooth ash-plaster mixtures were implanted into the defects of 8 human jaws. 48 intraoral radiograms taken with copper step wedge as reference at soon, 1st, 2nd, 4th, and 6th week after implantation of mixture were used. X-ray taking was standardized by using Rinn XCP device customized directly to the individual dentition with resin bite block. The images inputted by Quick scanner were digitized and analyzed by NIH image program. Cu-equivalent values were measured at the implanted sites from the periodic digital images. Analysis was performed by the bidirectional subtraction with color enhancement and the surface plot of resliced contiguous image. The obtained results by the two methods were compared with Cu-equivalent value changes. The average determination coefficient of Cu-equivalent equations was 0.9988 and the coefficient of variation of measured Cu values ranged from 0.08-0.10. The coefficient of variation of Cu-equivalent values measured at the areas of the mixture and the bone by the conversion equation ranged from 0.06-0.09. The analyzed results by the bidirectional subtraction with color enhancement were coincident with the changes of Cu-equivalent values. The surface plot of the resliced contiguous image showed the three dimensional view of the longitudinal bone changes on one image and also coincident with Cu-equivalent value changes after implantation. The bidirectional subtraction with color enhancement and the surface plot of the resliced contiguous image was very effective and reasonable to analyze clinically and qualitatively the longitudinal bone change. These methods are expected to be applicable to the non-destructive test in other fields.

  14. Videodensitometric assessment of right and left ventricular functions by digital subtraction angiography

    International Nuclear Information System (INIS)

    Ikeda, Hisao; Yoshiga, Osamu; Shibao, Keigo

    1987-01-01

    Intravenous digital subtraction (DS) ventriculography was performed in a series of 50 patients with heart diseases to determine right and left ventricular volumes and systolic indices. Right ventricular volume and right ventricular ejection fraction obtained by DS ventriculography were well correlated with those by geometric methods. In 43 patients with left ventricular ejection fraction of 55 % or greater, end-diastolic volume, stroke volume, and ejection fraction in the right ventricle did not differ from those in the left ventricle ; however, both the 1/3 ejection fraction and the peak ejection rate of the right ventricle were significantly lower than those of the left ventricle, suggesting the different modes of left and right ventricular contraction. In the other seven patients with chronic left ventricular failure, right ventricular systolic function may be preserved, even when left ventricular function is severely impaired. Digital subtraction ventriculography has proved to be a simple, useful method in the quanlitative and quantitative assessments of the right and left ventricles. (Namekawa, K.)

  15. Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography

    Directory of Open Access Journals (Sweden)

    Wilton Mitsunari Takeshita

    2013-01-01

    Full Text Available Background: To compare the diagnostic accuracy of three different imaging systems: Direct digital radiography system (DDR-CMOS, four types of filtered images, and a priori and a posteriori registration of digital subtraction radiography (DSR in the diagnosis of proximal defects. Materials and Methods: The teeth were arranged in pairs in 10 blocks of vinyl polysiloxane, and proximal defects were performed with drills of 0.25, 0.5, and 1 mm diameter. Kodak RVG 6100 sensor was used to capture the images. A posteriori DSR registrations were done with Regeemy 0.2.43 and subtraction with Image Tool 3.0. Filtered images were obtained with Kodak Dental Imaging 6.1 software. Images (n = 360 were evaluated by three raters, all experts in dental radiology. Results: Sensitivity and specificity of the area under the receiver operator characteristic (ROC curve (Az were higher for DSR images with all three drills (Az = 0.896, 0.979, and 1.000 for drills 0.25, 0.5, and 1 mm, respectively. The highest values were found for 1-mm drills and the lowest for 0.25-mm drills, with negative filter having the lowest values of all (Az = 0.631. Conclusion: The best method of diagnosis was by using a DSR. The negative filter obtained the worst results. Larger drills showed the highest sensitivity and specificity values of the area under the ROC curve.

  16. Large renal angiomyolipomas: digital subtraction angiographic grading and presentation with bleeding

    International Nuclear Information System (INIS)

    Rimon, U.; Duvdevani, M.; Garniek, A.; Golan, G.; Bensaid, P.; Ramon, J.; Morag, B.

    2006-01-01

    AIM: To investigate whether a grading system of renal AMLs based on digital subtraction angiography (DSA) and computerized tomography (CT), could help to select patients for embolization. MATERIALS AND METHODS: Thirty patients with 35 renal angiomyolipomas (size range 4-20cm, mean 9.9cm) underwent both digital subtraction angiography (DSA) and computed tomography (CT). Based on the DSA appearance the tumours were graded into three grades: grade I, minimal vascularity; grade II, moderate vascularity; grade III, marked vascularity. RESULTS: There were seven grade I (mean 9.3cm, range 4.5-20cm), 18 grade II (mean 8.9cm, range 5-18cm) and 10 grade III tumours (mean 12.1cm, range 4-20cm). Five grade I tumours did not cause symptoms (71%) and two caused flank pain and haematuria, respectively (14.3% each). Nine of the grade II tumours were asymptomatic (50%), seven caused bleeding (39%) and two caused flank pain (11%). Four grade III tumours were asymptomatic (40%), five caused bleeding (50%) and one pain (10%). CONCLUSIONS: According to our criteria, large angiomyolipomas with minimal vascularity are less likely to bleed, and do not need prophylactic treatment. This needs to be confirmed in larger studies

  17. Quantitative analysis of errors in alveolar crest level caused by discrepant projection geometry in digital subtraction radiography: an in vivo study.

    Science.gov (United States)

    Huh, Kyung-Hoe; Lee, Sam-Sun; Jeon, In-Seong; Yi, Won-Jin; Heo, Min-Suk; Choi, Soon-Chul

    2005-12-01

    This study compared the difference between 3 intraoral radiographic techniques on digital subtraction radiography (DSR) in vivo that are commonly used in a clinical setting. We evaluated and statistically analyzed the errors in the DSR image in 6 regions with 3 radiographic techniques: paralleling technique with a bite block attached to XCP, paralleling technique using XCP, and bisecting-angle technique. The amount of error using the bisecting-angle technique was too large for DSR, compared to that of the paralleling technique with a bite block attached to XCP. In the mandibular anterior region, the paralleling technique using XCP was not different from paralleling technique with a bite block attached to XCP. The lowest degree of error was present in the anterior region whereas the highest was present in the molar region. Bisecting-angle technique should be avoided, and paralleling technique using XCP can be used in the mandibular anterior region for DSR.

  18. Assessment of blood supply to intracranial pathologies in children using MR digital subtraction angiography

    International Nuclear Information System (INIS)

    Chooi, Weng Kong; Coley, Stuart C.; Connolly, Dan J.A.; Griffiths, Paul D.

    2006-01-01

    MR digital subtraction angiography (MR-DSA) is a contrast-enhanced MR angiographic sequence that enables time-resolved evaluation of the cerebral circulation. We describe the feasibility and technical success of our attempts at MR-DSA for the assessment of intracranial pathology in children. We performed MR-DSA in 15 children (age range 5 days to 16 years) referred for MR imaging because of known or suspected intracranial pathology that required a dynamic assessment of the cerebral vasculature. MR-DSA consisted of a thick (6-10 mm) slice-selective RF-spoiled fast gradient-echo sequence (RF-FAST) acquired before and during passage of an intravenously administered bolus of Gd-DTPA. The images were subtracted and viewed as a cine loop. MR-DSA was performed successfully in all patients. High-flow lesions were shown in four patients; these included vein of Galen aneurysmal malformation, dural fistula, and two partially treated arteriovenous malformations (AVMs). Low-flow lesions were seen in three patients, all of which were tumours. Normal flow was confirmed in eight patients including two with successfully treated AVMs, and in three patients with cavernomas. Our early experience suggests that MR-DSA is a realistic, non-invasive alternative to catheter angiography in certain clinical settings. (orig.)

  19. Digital subtraction angiography of lower limb arteries using and automatic table translation. Feasibility. Preliminary results

    International Nuclear Information System (INIS)

    Seka, R.; Amiel, M.; Boller, A.; Chapelon, C.; Clermont, A.; Revel, D.; Pinet, F.

    1988-01-01

    Digital subtraction angiography (DSA) as a method of evaluating lower limb arteries required examination of one limb at a time up to now. Moreover repeated injections of contrast material were necessary. This problem was mainly due to the relative small image intensifier field available and to the difficulty of repositionning the patient between mask and image acquisition. The preliminary results obtained with 24 patients studied on angiographic unit equipped with: a DSA system (DG 300-CGR) using 512x512 matrix size, an angiographic table (Angix M 200) allowing an automatic sequantial translation, a removable image intensifier using a 16 inch field below the table, are reported. Thus, all those characteristics allow DSA of lower limb arteries. Only one injection of contrast material (Ioxaglate: 80 ml at 8-10 ml/second) was used per procedure. This, usually, allows good quality examination of lower limb arteries [fr

  20. Idiopathic Thrombus in the Common Carotid Artery on Digital Subtraction Angiography

    Directory of Open Access Journals (Sweden)

    Anand Alurkar

    2012-01-01

    Full Text Available In the present study, we discuss the accuracy of digital subtraction angiography (DSA in diagnosis of thrombus in the common carotid artery and its role in the medical management of this disorder. Between 2006 and 2011, four patients (age group ranging from 26 to 48 years presented to our institution with symptoms of stroke. DSA in all these patients showed cigar-shaped filling defect in the common carotid artery. All the patients were managed successfully with anticoagulation treatment. Follow-up Duplex scan was done in all the patients. DSA is the gold standard to diagnose free floating thrombus in the common carotid artery. Medical management can be effective in these patients but a multidisciplinary team approach is needed for appropriate management.

  1. Evaluation of the superior vena cava system in children with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pariente, D.; Lacombe, P.

    1986-01-01

    The authors report a new pediatric application of digital subtraction angiography (DSA) that is the evaluation of the superior vena cava system. 22 children have been explored. All of them had a history of previous central venous catheter placement for parenteral nutrition (13), hemodialysis (5), chemotherapy or antibiotic therapy (4). The aim of the examination was to obtain a venous mapping before a new catheter placement (14 cases) or to look for a venous thrombosis origin of superior vena cava syndrom or septicemia (8 cases). Except failure of two examinations because of absence of venous injection site, DSA showed thrombosis of one vein in 7 cases and of multiple veins in 11 cases. A pulmonary embolus was also discovered. The authors conclude that this non invasive method yields very valuable information on superior vena cava system [fr

  2. [Affine transformation-based automatic registration for peripheral digital subtraction angiography (DSA)].

    Science.gov (United States)

    Kong, Gang; Dai, Dao-Qing; Zou, Lu-Min

    2008-07-01

    In order to remove the artifacts of peripheral digital subtraction angiography (DSA), an affine transformation-based automatic image registration algorithm is introduced here. The whole process is described as follows: First, rectangle feature templates are constructed with their centers of the extracted Harris corners in the mask, and motion vectors of the central feature points are estimated using template matching technology with the similarity measure of maximum histogram energy. And then the optimal parameters of the affine transformation are calculated with the matrix singular value decomposition (SVD) method. Finally, bilinear intensity interpolation is taken to the mask according to the specific affine transformation. More than 30 peripheral DSA registrations are performed with the presented algorithm, and as the result, moving artifacts of the images are removed with sub-pixel precision, and the time consumption is less enough to satisfy the clinical requirements. Experimental results show the efficiency and robustness of the algorithm.

  3. Combined use of intraarterial digital subtraction angiography with conventional retrograde brachial vertebral angiography

    International Nuclear Information System (INIS)

    Yamaguchi, Tatsuo; Ogawa, Toshihide; Inugami, Atsushi; Kawata, Yasushi; Shishido, Fumio; Uemura, Kazuo

    1985-01-01

    For 102 patients who had the examination of conventional bilaterally retrograde brachial vertebral angiography (retrograde VAG), intraarterial digital subtraction angiography (DSA) was successively performed to investigate steno-occlusive lesions of proximal vertebral and subclavian arteries. All the patients had no complication due to the DSA procedure. In 50% of 72 ischemic stroke cases, positive findings were found either in the origin of the vertebral artery or in the subclavian artery. Stenosis of more than 50% of the lumen of the vertebral artery were found in 14% of the cases at the origin of the right one and also in 14% in the left one. Occlusion of the vertebral artery was found in 4% in the left side only. In 30 cases with non-ischemic brain diseases, positive findings were noted in 10%. Intraarterial DSA combined with retrograde VAG was thought to be useful, especially in the examination for ischemic stroke. (author)

  4. Digital subtraction angiography of inferior gluteal artery through the infusion catheter of chemotherapy for bladder cancer

    International Nuclear Information System (INIS)

    Ishikawa, Satoru; Noguchi, Ryosuke; Kanoh, Shori; Shimazui, Toru; Uchida, Katsunori; Nemoto, Ryosuke; Koiso, Kenkichi

    1987-01-01

    More than fifty patients of invasive bladder cancer had been treated by selective intra-arterial chemotherapy through the inferior or superior gluteal arteries. The distribution of infused drugs had been evaluated by RI-angiography through a thin arterial infusion catheter. This time we performed digital subtraction angiography (DSA) through an infusion catheter in order to know the precise distribution of infused materials in seven patients with locally advanced bladder cancer. Pharmaco-DSA with norepinephrine was also done in four patients. Satisfactory spatial and contrast resolution were gained in four patients and pharmaco-DSA showed better quality. In our experience DSA through intra-arterial infusion catheter was a useful procedure in the evaluation of distribution of infused drugs. (author)

  5. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Kocasarac, Husniye Demirturk [Dept. of Comprehensive Dentistry, The University of Texas Health Science Center, San Antonio (United States); Celenk, Peruze [Dept. of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ondokuz Mayis University, Samsun (Turkmenistan)

    2017-06-15

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images.

  6. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    Science.gov (United States)

    Celenk, Peruze

    2017-01-01

    Purpose Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Materials and Methods Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. Results The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. Conclusion The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (Ppanoramic images. PMID:28680846

  7. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    International Nuclear Information System (INIS)

    Kocasarac, Husniye Demirturk; Celenk, Peruze

    2017-01-01

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images

  8. A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced) and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Nakiri, Guilherme S.; Santos, Antonio C.; Abud, Thiago G.; Abud, Daniel G., E-mail: gsnakiri@yahoo.com.b [University of Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Medical School. Div. of Radiology; Aragon, Davi C. [University of Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Medical School. Div. of Statistics; Colli, Benedicto O. [University of Sao Paulo (USP), Ribeirao Preto, SP (Brazil). Medical School. Div. of Neurosurgery

    2011-07-01

    Purpose: to compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. Introduction: many embolized aneurysms are subject to a recurrence of intra-aneurysmal filling. Traditionally, imaging surveillance of coiled aneurysms has consisted of repeated digital subtraction angiography. However, this method has a small but significant risk of neurological complications, and many authors have advocated the use of noninvasive imaging methods for the surveillance of embolized aneurysms. Methods: forty-three aneurysms in 30 patients were studied consecutively between November 2009 and May 2010. Two interventional neuro radiologists rated the time-of-flight-magnetic resonance angiography, the contrast enhanced-magnetic resonance angiography, and finally the digital subtraction angiography, first independently and then in consensus. The status of aneurysm occlusion was assessed according to the Raymond scale, which indicates the level of recanalization according to degrees: Class 1: excluded aneurysm; Class 2: persistence of a residual neck; Class 3: persistence of a residual aneurysm. The agreement among the analyses was assessed by applying the Kappa statistic. Results: inter-observer agreement was excellent for both methods (K = 0.93; 95 % CI: 0.84-1). Inter-technical agreement was almost perfect between time-of-flight-magnetic resonance angiography and digital subtraction angiography (K = 0.98; 95 % CI: 0.93-1) and between time-of-flight-magnetic resonance angiography and contrast enhanced-magnetic resonance angiography (K = 0.98; 95% CI: 0.93-1). Disagreement occurred in only one case (2.3%), which was classified as Class I by time-of-flight-magnetic resonance angiography and Class II by digital subtraction angiography. The agreement between contrast

  9. A comparison between magnetic resonance angiography at 3 teslas (time-of-flight and contrast-enhanced and flat-panel digital subtraction angiography in the assessment of embolized brain aneurysms

    Directory of Open Access Journals (Sweden)

    Guilherme S. Nakiri

    2011-01-01

    Full Text Available PURPOSE: To compare the time-of-flight and contrast-enhanced- magnetic resonance angiography techniques in a 3 Tesla magnetic resonance unit with digital subtraction angiography with the latest flat-panel technology and 3D reconstruction in the evaluation of embolized cerebral aneurysms. INTRODUCTION: Many embolized aneurysms are subject to a recurrence of intra-aneurismal filling. Traditionally, imaging surveillance of coiled aneurysms has consisted of repeated digital subtraction angiography. However, this method has a small but significant risk of neurological complications, and many authors have advocated the use of noninvasive imaging methods for the surveillance of embolized aneurysms. METHODS: Forty-three aneurysms in 30 patients were studied consecutively between November 2009 and May 2010. Two interventional neuroradiologists rated the time-of-flight-magnetic resonance angiography, the contrast-enhanced-magnetic resonance angiography, and finally the digital subtraction angiography, first independently and then in consensus. The status of aneurysm occlusion was assessed according to the Raymond scale, which indicates the level of recanalization according to degrees: Class 1: excluded aneurysm; Class 2: persistence of a residual neck; Class 3: persistence of a residual aneurysm. The agreement among the analyses was assessed by applying the Kappa statistic. RESULTS: Inter-observer agreement was excellent for both methods (K = 0.93; 95 % CI: 0.84-1. Inter-technical agreement was almost perfect between time-of-flight-magnetic resonance angiography and digital subtraction angiography (K = 0.98; 95 % CI: 0.93-1 and between time-of-flight-magnetic resonance angiography and contrast-enhanced-magnetic resonance angiography (K = 0.98; 95% CI: 0.93-1. Disagreement occurred in only one case (2.3%, which was classified as Class I by time-of-flight-magnetic resonance angiography and Class II by digital subtraction angiography. The agreement between

  10. Pilot study: digital subtraction radiography as a tool to assess alveolar bone changes in periodontitis patients under treatment with subantimicrobial doses of doxycycline

    NARCIS (Netherlands)

    Goren, A.D.; Dunn, S.M.; Wolff, M.; van der Stelt, P.F.; Colosi, D.C.; Golub, L.M.

    2008-01-01

    Background Subtle changes in marginal alveolar bone level can be demonstrated using digital subtraction of sequential radiographs. Objective We aimed to evaluate the practical application of geometrically corrected digital subtraction in a clinical study of alveolar bone response to a drug

  11. A comparative study on the accuracy of digital subtraction radiography according to the acquisition methods of reconstructed images

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Young June; Jeon, In Seong; Heo, Min Suk; Park, Tae Won [College of Dentistry, Seoul National University, Seoul (Korea, Republic of); Lee, Sam Sun; Choi, Soon Chul [Department of Dentistry, Inje University Sanggyepaik Hospital, Seoul (Korea, Republic of); Kim, Jong Dae [Division of Information and Communication Engineering, Hallym University, Chuncheon (Korea, Republic of)

    2002-06-15

    To compare the accuracy of digital subtraction images acquired by two different methods different in positioning four reference points for geometrical standardization. A total of 36 digital radiographic images of 6 volunteers were taken at the areas of the incisor, premolar, and molar of both the maxilla and mandible using the Digora system. Each image was moved 4 mm vertically and horizontally. Four oral and maxillofacial radiologists performed digital subtraction radiography between the paired images before and after movement using Emago (Oral Diagnostic Systems, Amsterdam, The Netherlands) and Sunny (Biomedisys Co., Seoul, Korea). The standard deviation of the internal gray value in Region of Interest (ROI) was statistically analyzed between the two programs using the paired t-test. The standard deviation of pixel gray values from the digital subtraction images using the Sunny program were lower than that of the Emago program (p<0.05). All observers showed significant differences between each other when the Sunny program was used (p<0.05), but one observer showed a significantly higher score than other observers when they used Emago (p<0.05). The standard deviations of premolar area from both Sunny and Emago programs were significantly higher than those of anterior and molar regions (p<0.05). The subtracted images using the Sunny program were more accurate and sensitive than those taken using the Emago program.

  12. Digital subtraction radiography evaluation of the bone repair process of chronic apical periodontitis after root canal treatment.

    Science.gov (United States)

    Benfica e Silva, J; Leles, C R; Alencar, A H G; Nunes, C A B C M; Mendonça, E F

    2010-08-01

    To monitor radiographically the progress of bone repair within chronic periapical lesions after root canal treatment using digital subtraction radiography (DSR). Twelve patients with 17 single-rooted teeth with chronic apical periodontitis associated with an infected necrotic pulp were selected for root canal treatment. Periapical radiographs were taken before treatment (baseline) and immediately post-treatment, 45, 90, 135 and 180 days after treatment. The radiographic protocol included the use of individualized film holders with silicone bite blocks. The six radiographic images were digitized and submitted to digital subtraction using DSR software, resulting in five subtracted images (SI). Quantitative analysis of these SI was performed using Image Tool software to assess pixel value changes, considering a step-wedge as the gold standard and a cut-off value of 128 pixels. The aim was to identify any increase or decrease in mineral density in the region of the periapical lesion. A minor decrease in mineral density at the canal filling session and a significant progressive mineral gain in the following evaluations (P < 0.001) occurred. Pairwise comparison of pixel grey values revealed that only the 180-day follow-up differed significantly from the previous SI. Digital subtraction radiography is a useful method for evaluating the progress of bone repair after root canal treatment. Noticeable mineral gain was observed approximately 90 days after root canal filling and definite bone repair after 180 days.

  13. Intra-aneurysmal flow patterns: illustrative comparison among digital subtraction angiography, optical flow, and computational fluid dynamics.

    Science.gov (United States)

    Brina, O; Ouared, R; Bonnefous, O; van Nijnatten, F; Bouillot, P; Bijlenga, P; Schaller, K; Lovblad, K-O; Grünhagen, T; Ruijters, D; Pereira, V Mendes

    2014-12-01

    Digital subtraction angiography is the gold standard vascular imaging and it is used for all endovascular treatment of intracranial anerysms. Optical flow imaging has been described as a potential method to evaluate cerebral hemodynamics through DSA. In this study, we aimed to compare the flow patterns measured during angiography, by using an optical flow method, with those measured by using computational fluid dynamics in intracranial aneurysms. A consecutive series of 21 patients harboring unruptured saccular intracranial aneurysms who underwent diagnostic angiography before treatment was considered. High-frame-rate digital subtraction angiography was performed to obtain an intra-aneurysmal velocity field by following the cardiac-modulated contrast wave through the vascular structures by using optical flow principles. Additionally, computational fluid dynamics modeling was performed for every case by using patient-specific inlet-boundary conditions measured with the optical flow method from both DSA and 3D rotational angiography datasets. Three independent observers compared qualitatively both the inflow direction and the apparent recirculation in regular DSA, optical flow images, and computational fluid dynamics flow patterns for each patient; κ statistics were estimated. We included 21 patients. In 14 of these 21, the flow patterns were conclusive and matching between the optical flow images and computational fluid dynamics within the same projection view (κ = .91). However, in only 8 of these 14 patients the optical flow images were conclusive and matching regular DSA images (observer κ = 0.87). In 7 of the 21 patients, the flow patterns in the optical flow images were inconclusive, possibly due to improper projection angles. The DSA-based optical flow technique was considered qualitatively consistent with computational fluid dynamics outcomes in evaluating intra-aneurysmal inflow direction and apparent recirculation. Moreover, the optical flow technique

  14. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    International Nuclear Information System (INIS)

    Hanson, Eric H.; Roach, Cayce J.; Ringdahl, Erik N.; Wynn, Brad L.; DeChancie, Sean M.; Mann, Nathan D.; Diamond, Alan S.; Orrison, William W.

    2011-01-01

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  15. Evaluation of the cardiovascular system by digital subtraction angiography in 246 patients

    Energy Technology Data Exchange (ETDEWEB)

    Higuma, Kikuhiko; Ohta, Takashi; Hiroto, Seiji

    1987-07-01

    Usefulness of intravenous digital subtraction angiography (DSA) was examined in 246 patients with cardiovascular disorders. This examination was done by centrally intravenous DSA (CIVDSA) in all patients to reduce the risks and discomforts by peripheral intravenous DSA. 1) CIVDSA could be done safely in patients aged 18 to 81 years. 2) The good diagnostic quality by CIVDSA was obtained in 81.3% of patients. These images were classified into 7 groups according to the cardiovascular system, that is, the jugular arteries, the upper extremity arteries, the thoracic aorta, the left ventricle, the abnominal aorta, the renal arteries, and the lower extremity arteries, whose rate of good diagnostic quality were 100%, 70%, 67.7%, 79.5%, 84.8%, 87%, and 71.4% respectively. 3) The poor diagnostic quality was obtained in 18.7%. 4) The severe complications were not found in any case during this examination. Our results indicate that DSA is the safe, simple and useful method to obtain the diagnostic quality image of the cardiovascular system, especially, of the occulsive arterial disease, the aortic aneurisma, the renovascular stenosis and the cardiac function of postmyocardial infarction, even in aged patients.

  16. Analysis of the venous channel within the clivus using multidetector computed tomography digital subtraction venography.

    Science.gov (United States)

    Mizutani, Katsuhiro; Toda, Masahiro; Kurasawa, Jun; Akiyama, Takenori; Fujiwara, Hirokazu; Jinzaki, Masahiro; Yoshida, Kazunari

    2017-03-01

    Although neuroradiologists and skull base neurosurgeons are aware of the existence of veins within the clivus, such vessels have seldom been described in the literature. The aim of the present study is to elucidate the detailed venous structure of the clivus. Computed tomography digital subtraction venography (CT-DSV) images of 50 unruptured aneurysm cases were examined retrospectively. Eighteen emissary veins were identified in 14 (28.0%) cases. A half of the emissary veins connected the inferior petrosal sinus with the inferior petro-occipital vein (IPOV) in the middle clivus. The clival diploic vein (CDV) was identified in 14.0% of cases, 42.9% of which had the clivus of the presellar type. The CDV was connected to the posterior intercavernous sinus or the rostral end of the basilar plexus superiorly, and was connected to the IPOV, anterior condylar vein, marginal sinus, or the anterior condylar confluence. The CDV provides collateral channels between the cavernous sinus and the internal jugular vein and the inferior petrosal sinus and the IPOV. Understanding of the emissary veins in the clivus and the CDV is valuable for skull base surgery, especially for endonasal endoscopic skull base procedures.

  17. Remapping of digital subtraction angiography on a standard fluoroscopy system using 2D-3D registration

    Science.gov (United States)

    Alhrishy, Mazen G.; Varnavas, Andreas; Guyot, Alexis; Carrell, Tom; King, Andrew; Penney, Graeme

    2015-03-01

    Fluoroscopy-guided endovascular interventions are being performing for more and more complex cases with longer screening times. However, X-ray is much better at visualizing interventional devices and dense structures compared to vasculature. To visualise vasculature, angiography screening is essential but requires the use of iodinated contrast medium (ICM) which is nephrotoxic. Acute kidney injury is the main life-threatening complication of ICM. Digital subtraction angiography (DSA) is also often a major contributor to overall patient radiation dose (81% reported). Furthermore, a DSA image is only valid for the current interventional view and not the new view once the C-arm is moved. In this paper, we propose the use of 2D-3D image registration between intraoperative images and the preoperative CT volume to facilitate DSA remapping using a standard fluoroscopy system. This allows repeated ICM-free DSA and has the potential to enable a reduction in ICM usage and radiation dose. Experiments were carried out using 9 clinical datasets. In total, 41 DSA images were remapped. For each dataset, the maximum and averaged remapping accuracy error were calculated and presented. Numerical results showed an overall averaged error of 2.50 mm, with 7 patients scoring averaged errors < 3 mm and 2 patients < 6 mm.

  18. Comparative experimental study of dual energy subtraction and conventional digital radiography on chest

    International Nuclear Information System (INIS)

    Huang Rui; Feng Gansheng; Li Lin; Wei Qinghai

    2005-01-01

    Objective: To compare the efficiency of dual energy subtraction and conventional direct digital radiography in signal detecting ability. Methods: 200 plastic balls which were 4 mm in diameter were taken as signals and were placed on a 10 cm thick plastic board and the right upper thorax of a healthy volunteer. The signals were examined by DES and CDR separately and were estimated by 3 radiologists with 5-value-differentiation method. ROC curve analysis was made by ROC kit software. Results: when signals on plastic board were detected by CDR and DES, ROC curve analysis indicated that there was no significant difference (P=0.4851 > 0.05, two-tailed) between the area under the ROC curves of the two methods (Az=0.9931 for CDR and Az=0.9879 for DES). The difference was significant (P=0.0002 <0.01, two-tailed) between the area under the ROC curves of CDR and DES (Az=0.7276 for CDR and Az=0.8561 for DES), when the signals on the right upper thorax of a volunteer were detected by the two methods. Conclusion: DES surpasses CDR in detecting signals on thorax without superposition of ribs. There is good outlook in the application of DES in thorax examination. (authors)

  19. Patient radiation dose from computed tomography angiography and digital subtraction angiography of the brain

    Science.gov (United States)

    Netwong, Y.; Krisanachinda, A.

    2016-03-01

    The 64-row multidetector computed tomography angiography (64-MDCTA) provides vascular image quality of the brain similar to digital subtraction angiography (DSA), but the effective dose of CTA is lower than DSA studied in phantom. The purpose of this study is to evaluate the effective dose from 64-MDCTA and DSA. Effective dose (according to ICRP 103) from 64-MDCTA and DSA flat panel detector for cerebral vessels examination of the brain using standard protocols as recommended by the manufacturer was calculated for 30 cases of MDCTA (15 male and 15 female).The mean patient age was 49.5 (23-89) yrs. 30 cases of DSA (14 male and 16 female), the mean patient age was 46.8 (21-81) yrs. For CTA, the mean effective dose was 3.7 (2.82- 5.19) mSv. For DSA, the mean effective dose was 5.78 (3.3-10.06) mSv. The effective dose of CTA depends on the scanning protocol and scan length. Low tube current can reduce patient dose whereas the number of exposures and number of series in 3D rotational angiography (3D RA) resulted in increasing effective dose in DSA patients.

  20. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT

    Directory of Open Access Journals (Sweden)

    Cristian T. Badea

    2013-01-01

    Full Text Available CT and digital subtraction angiography (DSA are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA. This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging.

  1. Magnetization spoiling in radial FLASH contrast-enhanced MR digital subtraction angiography.

    Science.gov (United States)

    Vakil, Parmede; Ansari, Sameer A; Hurley, Michael C; Bhat, Himanshu; Batjer, H Hunt; Bendok, Bernard R; Eddleman, Christopher S; Carroll, Timothy J

    2012-07-01

    To increase the in-plane spatial resolution and image update rates of 2D magnetic resonance (MR) digital subtraction angiography (DSA) pulse sequences to 0.57 × 0.57 mm and 6 frames/sec, respectively, for intracranial vascular disease applications by developing a radial FLASH protocol and to characterize a new artifact, not previously described in the literature, which arises in the presence of such pulse sequences. The pulse sequence was optimized and artifacts were characterized using simulation and phantom studies. With Institutional Review Board (IRB) approval, the pulse sequence was used to acquire time-resolved images from healthy human volunteers and patients with x-ray DSA-confirmed intracranial vascular disease. Artifacts were shown to derive from inhomogeneous spoiling due to the nature of radial waveforms. Gradient spoiling strategies were proposed to eliminate the observed artifact by balancing gradient moments across TR intervals. The resulting radial 2D MR DSA sequence (2.6 sec temporal footprint, 6 frames/sec with sliding window factor 16, 0.57 × 0.57 mm in-plane) demonstrated small vessel detail and corroborated x-ray DSA findings in intracranial vascular imaging studies. Appropriate gradient spoiling in radial 2D MR DSA pulse sequences improves intracranial vascular depiction by eliminating circular banding artifacts. The proposed pulse sequence may provide a useful addition to clinically applied 2D MR DSA scans. Copyright © 2012 Wiley Periodicals, Inc.

  2. Predictive value of digital subtraction angiography in patients with tuberculous meningitis

    International Nuclear Information System (INIS)

    Rojas-Echeverri, L.A.; Soto-Hernandez, J.L.; Garza, S.; Martinez-Zubieta, R.; Miranda, L.I.; Garcia-Ramos, G.; Zenteno, M.

    1996-01-01

    Digital subtraction angiography (DSA) was performed in 24 adults with tuberculous meningitis (TBM) and results were correlated with 24 admission and 16 follow-up CT examinations. 19 MRI studies and clinical outcome at a mean follow-up of 44 weeks. DSA was abnormal in 11 patients. Abnormal DSA was associated with advenced clinical stages of the Medical Research Council classification, admission CT with hydrocephalus or gyral cortical enhancement. MRI disclosed brain infarcts not seen on initial CT in 8 cases. Of seven patients who died, 4 had abnormal and 3 normal DSA. Among patients who survived, those with normal DSA had a better functional outcome by Karnofsky scores. During follow-up infarcts were evident in 16 patients. Abnormal DSA in relation to brain infarcts had a sensitivity of 0.56, specificity 0.75, positive predictive value 0.82 and negative predictive value 0.46. A single arteriogram does not predict the outcome in patients with TBM and its value is limited in the assessment of vascular complications of TBM. Angiography in TBM is justified only in specific clinical trials to assess new therapeutic modalities against infarcts. (orig.)

  3. Describable ability of blood vessels in head and neck by intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Minakuchi, Kazuo; Takada, Keiji; Nakamura, Kenji

    1989-01-01

    Ninety-four patients with various symptoms of the head and neck were studied by intravenous digital subtraction angiography (IV-DSA). Abnormal findings were obesrved in 12 patients; one with aneurysm in the left internal carotid artery, and 11 with obstruction in the right middle cerebral artery (2), the right internal carotid artery (one), the left subclavian artery (one), the right vertebral artery (6), and the left vertebral artery (one). Motion artifacts were observed in 2 patients. The vertebral arteries were bilaterally equal in size in 42%, and the left vertebral artery was bigger than the right one in 38%. The superior sagittal dural sinus was clearly imaged in 94%. The incidence of excellent images was higher in the right sided than the left sided vein -- 85% vs 50% for the transverse dural sinus, 84% vs 54% for the sigmoid dural sinus, and 88% vs 57% for the jugular vein. Sites of excellent images were all of the dural sinuses and veins (37 cases), confined to the right side (37), confined to the left side (8), and undefined (12). (N.K.)

  4. A LabVIEW Platform for Preclinical Imaging Using Digital Subtraction Angiography and Micro-CT.

    Science.gov (United States)

    Badea, Cristian T; Hedlund, Laurence W; Johnson, G Allan

    2013-01-01

    CT and digital subtraction angiography (DSA) are ubiquitous in the clinic. Their preclinical equivalents are valuable imaging methods for studying disease models and treatment. We have developed a dual source/detector X-ray imaging system that we have used for both micro-CT and DSA studies in rodents. The control of such a complex imaging system requires substantial software development for which we use the graphical language LabVIEW (National Instruments, Austin, TX, USA). This paper focuses on a LabVIEW platform that we have developed to enable anatomical and functional imaging with micro-CT and DSA. Our LabVIEW applications integrate and control all the elements of our system including a dual source/detector X-ray system, a mechanical ventilator, a physiological monitor, and a power microinjector for the vascular delivery of X-ray contrast agents. Various applications allow cardiac- and respiratory-gated acquisitions for both DSA and micro-CT studies. Our results illustrate the application of DSA for cardiopulmonary studies and vascular imaging of the liver and coronary arteries. We also show how DSA can be used for functional imaging of the kidney. Finally, the power of 4D micro-CT imaging using both prospective and retrospective gating is shown for cardiac imaging.

  5. Evaluation of the cardiovascular system by digital subtraction angiography in 246 patients

    International Nuclear Information System (INIS)

    Higuma, Kikuhiko; Ohta, Takashi; Hiroto, Seiji

    1987-01-01

    Usefulness of intravenous digital subtraction angiography (DSA) was examined in 246 patients with cardiovascular disorders. This examination was done by centrally intravenous DSA (CIVDSA) in all patients to reduce the risks and discomforts by peripheral intravenous DSA. 1) CIVDSA could be done safely in patients aged 18 to 81 years. 2) The good diagnostic quality by CIVDSA was obtained in 81.3 % of patients. These images were classified into 7 groups according to the cardiovascular system, that is, the jugular arteries, the upper extremity arteries, the thoracic aorta, the left ventricle, the abnominal aorta, the renal arteries, and the lower extremity arteries, whose rate of good diagnostic quality were 100 %, 70 %, 67.7 %, 79.5 %, 84.8 %, 87 %, and 71.4 % respectively. 3) The poor diagnostic quality was obtained in 18.7 %. 4) The severe complications were not found in any case during this examination. Our results indicate that DSA is the safe, simple and useful method to obtain the diagnostic quality image of the cardiovascular system, especially, of the occulsive arterial disease, the aortic aneurisma, the renovascular stenosis and the cardiac function of postmyocardial infarction, even in aged patients. (author)

  6. Clinical application of cerebral circulation time measured by intra-arterial digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Yoshikazu; Shima, Takeshi; Nishida, Masahiro; Yamane, Kanji; Okita, Shinji; Yoshida, Akira; Naoe, Yasutaka; Shiga, Naoko (Chugoku Rosai Hospital, Hiroshima (Japan))

    1994-08-01

    Digital subtraction angiography (DSA) made it possible not only to visualize the intracranial fine vasculature but also measure the density of contrast medium at the arbitrary region of interest (ROI). In this study we applied this intra-arterial DSA (IA-DSA) to measure cerebral circulation time by obtaining time-density curve at the two ROI's at the C3-C4 portion and the Rolandic vein. Circulation time was defined by the time difference between the peak optical density time at the two sites. The control value of circulation time was 3.4 sec on the average, which correlated with the age of cases. In patients with occlusive cerebrovascular diseases such as carotid arterial occlusion or with mass lesions such as hematoma and brain tumor, circulation time was significantly delayed. On the contrary, circulation time in arteriovenous malformation was demonstrated to be very short. Additionally circulation time was investigated in subarachnoid hemorrhage due to ruptured aneurysm. Circulation time in patients with none, slight to moderate and severe vasospasm following subarachnoid hemorrhage were 3.6, 4.3 and 6.8 sec on the average, respectively. And ten patients presenting with low densitity area on CT scans showed significantly long circulation time, 7.0 sec on the average. From these studies cerebral circulation time by IA-DSA would be one of the useful methods to clarify cerebral hemodynamics. (author).

  7. Developmental venous anomalies: appearance on whole-brain CT digital subtraction angiography and CT perfusion

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, Eric H. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); Amigenics, Inc, Las Vegas, NV (United States); Roach, Cayce J. [Advanced Medical Imaging and Genetics (Amigenics), Las Vegas, NV (United States); University of Nevada Las Vegas, School of Life Sciences, Las Vegas, NV (United States); Ringdahl, Erik N. [University of Nevada Las Vegas, Department of Psychology, Las Vegas, NV (United States); Wynn, Brad L. [Family Medicine Spokane, Spokane, WA (United States); DeChancie, Sean M.; Mann, Nathan D. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); Diamond, Alan S. [CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); Orrison, William W. [Touro University Nevada College of Osteopathic Medicine, Henderson, NV (United States); University of Nevada Las Vegas, Department of Health Physics and Diagnostic Sciences, 4505 Maryland Parkway, Box 453037, Las Vegas, NV (United States); CHW Nevada Imaging Company, Nevada Imaging Centers, Spring Valley, Las Vegas, NV (United States); University of Nevada School of Medicine, Department of Medical Education, Reno, NV (United States)

    2011-05-15

    Developmental venous anomalies (DVA) consist of dilated intramedullary veins that converge into a large collecting vein. The appearance of these anomalies was evaluated on whole-brain computed tomography (CT) digital subtraction angiography (DSA) and CT perfusion (CTP) studies. CT data sets of ten anonymized patients were retrospectively analyzed. Five patients had evidence of DVA and five age- and sex-matched controls were without known neurovascular abnormalities. CT angiograms, CT arterial-venous views, 4-D CT DSA and CTP maps were acquired on a dynamic volume imaging protocol on a 320-detector row CT scanner. Whole-brain CTP parameters were evaluated for cerebral blood flow (CBF), cerebral blood volume (CBV), time to peak (TTP), mean transit time (MTT), and delay. DSA was utilized to visualize DVA anatomy. Radiation dose was recorded from the scanner console. Increased CTP values were present in the DVA relative to the unaffected contralateral hemisphere of 48%, 32%, and 26%; and for the control group with matched hemispheric comparisons of 2%, -10%, and 9% for CBF, CBV, and MTT, respectively. Average effective radiation dose was 4.4 mSv. Whole-brain DSA and CTP imaging can demonstrate a characteristic appearance of altered DVA hemodynamic parameters and capture the anomalies in superior cortices of the cerebrum and the cerebellum. Future research may identify the rare subsets of patients at increased risk of adverse outcomes secondary to the altered hemodynamics to facilitate tailored imaging surveillance and application of appropriate preventive therapeutic measures. (orig.)

  8. Comparison of 3D magnetic resonance imaging and digital subtraction angiography for intracranial artery stenosis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ji Eun; Jung, Seung Chai; Kim, Ho Sung; Choi, Choong-Gon; Kim, Sang Joon; Lee, Deok Hee [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Lee, Sang Hun; Kwon, Sun U.; Kang, Dong-Wha; Kim, Jong S. [University of Ulsan College of Medicine, Department of Neurology, Ulsan (Korea, Republic of); Jeon, Ji Young [Gachon University, Department of Radiology, Gil Medical Center, Incheon (Korea, Republic of); Lee, Ji Ye [Soonchunhyang University Bucheon Hospital, Department of Radiology, Bucheon (Korea, Republic of); Kim, Seon-Ok [University of Ulsan College of Medicine, Department of Clinical Epidemiology and Biostatistics, Asan Medical Center, Seoul (Korea, Republic of)

    2017-11-15

    To compare three-dimensional high-resolution magnetic resonance imaging (3D HR-MRI) and digital subtraction angiography (DSA) for diagnosing and evaluating stenosis in the entire circle of Willis. The study included 516 intracranial arteries from 43 patients with intracranial artery stenosis (ICAS) who underwent both 3D HR-MRI and DSA within 1 month. Two readers independently diagnosed atherosclerosis, dissection, moyamoya disease and vasculitis, rated their diagnostic confidence for each vessel and measured the luminal diameters. Reference standard was made from clinico-radiologic diagnosis. Diagnostic accuracy, diagnostic confidence, the degree of stenosis and luminal diameter were assessed and compared between both modalities. For atherosclerosis, 3D HR-MRI showed better diagnostic accuracy (P =.03-.003), sensitivity (P =.006-.01) and positive predictive value (P ≤.001-.006) compared to DSA. Overall, the readers were more confident of their diagnosis of ICAS when using 3D HR-MRI (reader 1, P ≤.001-.007; reader 2, P ≤.001-.015). 3D HR-MRI showed similar degree of stenosis (P >.05) and higher luminal diameter (P <.05) compared to DSA. 3D HR-MRI might be useful to evaluate atherosclerosis, with better diagnostic confidence and comparable stenosis measurement compared to DSA in the entire circle of Willis. (orig.)

  9. In vivo optical imaging of amblyopia: Digital subtraction autofluorescence and split-spectrum amplitude-decorrelation angiography.

    Science.gov (United States)

    Guo, Lei; Tao, Jun; Xia, Fan; Yang, Zhi; Ma, Xiaoli; Hua, Rui

    2016-09-01

    Amblyopia is a visual impairment that is attributed to either abnormal binocular interactions or visual deprivation. The retina and choroids have been shown to be involved in the development of amblyopia. The purpose of this study was to investigate the retinal and choroidal microstructural abnormalities of amblyopia using digital subtraction autofluorescence and split-spectrum amplitude-decorrelation angiography (SSADA) approaches. This prospective study included 44 eyes of 22 patients with unilateral amblyopia. All patients who received indirect ophthalmoscopy, combined depth imaging spectral domain optical coherence tomography (OCT), SSADA-OCT, and macular blue light (BL-) and near-infrared (NIR-) autofluorescences underwent pupil dilation. The subfoveal choroidal thickness (SFCT) was measured. BL- and NIR-autofluorescences were determined for all patients and used to generate subtraction images with ImageJ software. The superficial, deep layers of the retina, and inner choroid layer were required for SSADA-OCT. For the normal eyes, a regularly increasing signal was observed in the central macula based on the subtraction images. In contrast, a decreased signal for the central patch or a reduced peak was detected in 16 of 22 amblyopic eyes (72.7%). The mean SFCT of the amblyopic eyes was greater than that of the fellow normal eyes (399.25 ± 4.944 µm vs. 280.58 ± 6.491 µm, respectively, P amblyopia using SSADA-OCT and digital subtraction images of autofluorescence. The mechanistic relationship of a thicker choroid and choroidal capillary atrophy with amblyopia remains to be described. The digital subtraction image confirmed the changes in the microstructure of the amblyopic retina as a supplementary approach to detect the progression of amblyopia. Lasers Surg. Med. 48:660-667, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. Regional myocardial coronary blood flow reserve in hypertrophic cardiomyopathy assessed by digital subtraction coronary angiography

    Energy Technology Data Exchange (ETDEWEB)

    Terashima, Satoshi; Nakamura, Takashi; Furukawa, Keizo (Kyoto Prefectural Univ. of Medicine (Japan)) (and others)

    1992-01-01

    Using digital subtraction coronary angiography (DSA), we evaluated the regional myocardial coronary blood flow reserve (rMFR) in 18 patients with hypertrophic cardiomyopathy (HCM). There were 13 patients with asymmetrical septal hypertrophy (ASH), and 5 with asymmetrical apical hypertrophy (AAH). Eight subjects without apparent cardiac abnormality served as controls. Relations between the rMFR and regional wall thickness, as determined by echocardiography, were also investigated. Peak contrast density (Cm) and time to Cm (Tm) were measured from digital angiograms at the middle and distal ventricular septum (VS) and at the apical and left ventricular posterior wall (PW). The rMFR of each region of interest was expressed as the ratio of Cm/Tm at the baseline and at peak hyperemic response induced by intracoronary administration of papaverine. The rMFR was significantly lower at the VS and apex in HCM than in controls: middle VS, 1.9[+-]0.5 vs 3.9[+-]0.5, p<0.001; distal VS, 2.0[+-]0.5 vs 4.4[+-]0.9, p<0.001; and the apex, 2.0[+-]0.7 vs 4.5[+-]1.6, p<0.01. However, it did not differ at the PW; 2.6[+-]0.9 vs 3.0[+-]0.9 between the 3 groups. The middle VS and apex, where the wall was the thickest, had the lowest rMFR in ASH and AAH. Furthermore, at the VS and apex, a curvilinear relationship was observed between the rMFR and wall thickness (rMFR=-0.88 ln WT+2.39, r=-0.57, p<0.001). These results indicated that disproportionate hypertrophy contributes to impairment of the rMFR, and that the decreased rMFR may be one of the significant causes of reversible myocardial ischemia in patients with HCM. (author).

  11. Radiographic techniques for digital mammography

    International Nuclear Information System (INIS)

    Horita, Katsuhei

    2007-01-01

    Since the differences in X-ray absorption between various breast tissues are small, a dedicated X-ray system for examination of the breast and a high-contrast, high-resolution screen/film system (SFM) (light-receiving system) are employed for X-ray diagnosis. Currently, however, there is a strong trend toward digital imaging in the field of general radiography, and this trend is also reflected in the field of mammographic examination. In fact, approximately 70% of facilities purchasing new mammography systems are now selecting a digital mammography system (DRM). Given this situation, this report reviews the differences between SFM and DRM and discusses the radiographic techniques and quality assurance procedures for digital mammography. (author)

  12. The comparative study on diagnostic validity of cerebral aneurysm by computed tomography angiography versus digital subtraction angiography after subarachnoid hemorrhage

    Directory of Open Access Journals (Sweden)

    Masih Saboori

    2011-01-01

    Full Text Available Background: In order to declare the preoperative diagnostic value of brain aneurysms, two radiological modalities, computed tomographic angiography and digital subtraction angiography were compared. Methods: In this descriptive analytic study, diagnostic value of computed tomographic angiography (CTA was com-pared with digital subtraction angiography (DSA. Sensitivity, specificity, positive and negative predictive values were calculated and compared between the two modalities. All data were analyzed with SPSS software, version 16. Results: Mean age of patients was 49.5 ± 9.13 years. 57.9 % of subjects were female. CTA showed 89% sensitivity and 100% specificity whereas DSA demonstrated 74% sensitivity and 100% specificity. Positive predictive value of both methods was 100%, but negative predictive value of CTA and DSA was 85% and 69%, respectively. Conclusions: Based on our data, CTA is a valuable diagnostic modality for detection of brain aneurysm and su-barachnoid hemorrhage.

  13. Nonlinear Geometric Warping of the Mask Image: A New Method for Reducing Misregistration Artifacts in Digital Subtraction Angiography

    International Nuclear Information System (INIS)

    Hayashi, Nobushige; Sakai, Toyohiko; Kitagawa, Manabu; Inagaki, Rika; Sadato, Norihiro; Ishii, Yasushi; Nishimoto, Yasuhiro; Tanaka, Masato; Fukushima, Tetsuya; Komuro, Hiroyuki; Ogura, Hisakazu; Kobayashi, Hidenori; Kubota, Toshihiko

    1998-01-01

    Purpose: Misregistration artifact is the major cause of image degradation in digital subtraction angiography (DSA). The purpose of this study was to evaluate the efficacy of a newly developed nonlinear geometric warping method to reduce misregistration artifact in DSA. Methods: The processing of the images was carried out on a workstation with a fully automatic computerized program. After making differential images with a lapracian filter, 49 regions of interest (ROIs) were set in the image to be processed. Each ROI of the live image scanned the corresponding ROI of the mask image searching for the best position to match itself. Each pixel of the mask image was shifted individually following the data calculated from the shifts of the ROIs. Five radiologists compared the images produced by the conventional parallel shift technique and those processed with this new method in 16 series of cerebral DSA. Results: In 14 of 16 series (88%), more radiologists judged the images processed with the new method to be better in quality. Small arteries near the skull base and veins of low density were clearly visualized in the images processed by the new method. Conclusion: This newly proposed method could be a simple and practical way to automatically reduce misregistration artifacts in DSA

  14. Synchrotron-based intra-venous K-edge digital subtraction angiography in a pig model: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Schueltke, Elisabeth [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada); Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, SK (Canada); Department of Neurological Sciences, Walton Medical Centre, University of Liverpool, Liverpool L97 LJ (United Kingdom)], E-mail: e.schultke@usask.ca; Fiedler, Stefan [European Molecular Biology Laboratory (EMBL), Nottkestrasse 85, 22603 Hamburg (Germany); Nemoz, Christian [European Synchrotron Radiation Facility (ESRF), 6 rue Horowitz, 38043 Grenoble (France); Ogieglo, Lissa [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada); Kelly, Michael E. [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada); Department of Neurosurgery, Section of Cerebrovascular and Endovascular Neurosurgery, Cleveland Clinic, 9500 Euclid Avenue, Cleveland, OH (United States); Crawford, Paul [Royal Veterinary College, Hawkshead Lane, North Mymms, Hatfield, Herfordshire AL9 7TA (United Kingdom); Esteve, Francois [INSERM U836-ESRF, 6 rue Horowitz, 38043 Grenoble (France); Brochard, Thierry; Renier, Michel; Requardt, Herwig; Le Duc, Geraldine [European Synchrotron Radiation Facility (ESRF), 6 rue Horowitz, 38043 Grenoble (France); Juurlink, Bernhard [Anatomy and Cell Biology, University of Saskatchewan, Saskatoon, SK (Canada); Meguro, Kotoo [Departments of Surgery, University of Saskatchewan, Saskatoon, SK (Canada)

    2010-03-15

    Background: K-edge digital subtraction angiography (KEDSA) combined with the tunability of synchrotron beam yields an imaging technique that is highly sensitive to low concentrations of contrast agents. Thus, contrast agent can be administered intravenously, obviating the need for insertion of a guided catheter to deliver a bolus of contrast agent close to the target tissue. With the high-resolution detectors used at synchrotron facilities, images can be acquired at high spatial resolution. Thus, the KEDSA appears particularly suited for studies of neurovascular pathology in animal models, where the vascular diameters are significantly smaller than in human patients. Materials and methods: This feasibility study was designed to test the suitability of KEDSA after intravenous injection of iodine-based contrast agent for use in a pig model. Four adult male pigs were used for our experiments. Neurovascular angiographic images were acquired using KEDSA with a solid state Germanium (Ge) detector at the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. Results: After intravenous injection of 0.9 ml/kg iodinated contrast agent (Xenetix), the peak iodine concentrations in the internal carotid and middle cerebral arteries reached 35 mg/ml. KEDSA images in radiography mode allowed the visualization of intracranial arteries of less than 1.5 mm diameter.

  15. Comparative study of conducting iliac angioplasties with digital subtraction and conventional angiography. Incidence on true (consumable) costs

    International Nuclear Information System (INIS)

    Brenot, P.; Raynaud, A.; Pernes, J.M.; Parola, J.L.; Gaux, J.C.

    1986-01-01

    Differences in time and cost were evaluated between the performance of iliac angioplasty with conventional (AC) and digital subtraction (AN) angiography, after a total of 27 angioplasties (13 with AC and 14 with AN). Excluding amortization of material and personnel costs, findings confirmed a certain number of advantages for AN: gain in time of about 34%, decrease of about 14% in charges, and notably of 83% in expenditure on films and 50% on contrast media [fr

  16. Classification-based summation of cerebral digital subtraction angiography series for image post-processing algorithms.

    Science.gov (United States)

    Schuldhaus, D; Spiegel, M; Redel, T; Polyanskaya, M; Struffert, T; Hornegger, J; Doerfler, A

    2011-03-21

    X-ray-based 2D digital subtraction angiography (DSA) plays a major role in the diagnosis, treatment planning and assessment of cerebrovascular disease, i.e. aneurysms, arteriovenous malformations and intracranial stenosis. DSA information is increasingly used for secondary image post-processing such as vessel segmentation, registration and comparison to hemodynamic calculation using computational fluid dynamics. Depending on the amount of injected contrast agent and the duration of injection, these DSA series may not exhibit one single DSA image showing the entire vessel tree. The interesting information for these algorithms, however, is usually depicted within a few images. If these images would be combined into one image the complexity of segmentation or registration methods using DSA series would drastically decrease. In this paper, we propose a novel method automatically splitting a DSA series into three parts, i.e. mask, arterial and parenchymal phase, to provide one final image showing all important vessels with less noise and moving artifacts. This final image covers all arterial phase images, either by image summation or by taking the minimum intensities. The phase classification is done by a two-step approach. The mask/arterial phase border is determined by a Perceptron-based method trained from a set of DSA series. The arterial/parenchymal phase border is specified by a threshold-based method. The evaluation of the proposed method is two-sided: (1) comparison between automatic and medical expert-based phase selection and (2) the quality of the final image is measured by gradient magnitudes inside the vessels and signal-to-noise (SNR) outside. Experimental results show a match between expert and automatic phase separation of 93%/50% and an average SNR increase of up to 182% compared to summing up the entire series.

  17. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    International Nuclear Information System (INIS)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan

    2009-01-01

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 μm 2 ). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0±5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO DSA =CO Fick . Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  18. Quantitative blood flow measurements in the small animal cardiopulmonary system using digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lin Mingde; Marshall, Craig T.; Qi, Yi; Johnston, Samuel M.; Badea, Cristian T.; Piantadosi, Claude A.; Johnson, G. Allan [Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States); Division of Pulmonary and Critical Care Medicine and Center for Hyperbaric Medicine and Environmental Physiology, Duke University Medical Center, Box 3823, Durham, North Carolina 27710 (United States); Department of Radiology, Center for In Vivo Microscopy and Department of Biomedical Engineering, Duke University Medical Center, Box 3302, Durham, North Carolina 27710 (United States)

    2009-11-15

    Purpose: The use of preclinical rodent models of disease continues to grow because these models help elucidate pathogenic mechanisms and provide robust test beds for drug development. Among the major anatomic and physiologic indicators of disease progression and genetic or drug modification of responses are measurements of blood vessel caliber and flow. Moreover, cardiopulmonary blood flow is a critical indicator of gas exchange. Current methods of measuring cardiopulmonary blood flow suffer from some or all of the following limitations--they produce relative values, are limited to global measurements, do not provide vasculature visualization, are not able to measure acute changes, are invasive, or require euthanasia. Methods: In this study, high-spatial and high-temporal resolution x-ray digital subtraction angiography (DSA) was used to obtain vasculature visualization, quantitative blood flow in absolute metrics (ml/min instead of arbitrary units or velocity), and relative blood volume dynamics from discrete regions of interest on a pixel-by-pixel basis (100x100 {mu}m{sup 2}). Results: A series of calibrations linked the DSA flow measurements to standard physiological measurement using thermodilution and Fick's method for cardiac output (CO), which in eight anesthetized Fischer-344 rats was found to be 37.0{+-}5.1 ml/min. Phantom experiments were conducted to calibrate the radiographic density to vessel thickness, allowing a link of DSA cardiac output measurements to cardiopulmonary blood flow measurements in discrete regions of interest. The scaling factor linking relative DSA cardiac output measurements to the Fick's absolute measurements was found to be 18.90xCO{sub DSA}=CO{sub Fick}. Conclusions: This calibrated DSA approach allows repeated simultaneous visualization of vasculature and measurement of blood flow dynamics on a regional level in the living rat.

  19. Comparisons of images simultaneously documented by digital subtraction coronary arteriography and cine coronary arteriography

    International Nuclear Information System (INIS)

    Kimura, Koji; Takamiya, Makoto; Yamamoto, Kazuo; Ohta, Mitsushige; Naito, Hiroaki

    1988-01-01

    Using an angiography apparatus capable of simultaneously processing digital subtraction angiograms and cine angiograms, the diagnostic capabilities of both methods for the coronary arteries (DSCAG and Cine-CAG) were compared. Twenty stenotic lesions of the coronary arteries of 11 patients were evaluated using both modalities. The severity of stenosis using DSCAG with a 512x512x8 bit matrix was semiautomatically measured on the cathode ray tube (CRT) based on enlarged images on the screen of a Vanguard cine projector which were of the same size as those of or 10 times larger than images of Cine-CAG. The negative and positive hard copies of DSCAG images were also compared with those of Cine-CAG. The correlation coefficients of the severity of stenosis by DSCAG and Cine-CAG were as follows: (1) the same size DSCAG images on CRT to Cine-CAG, 0.95, (2) 10 times enlarged DSCAG images on CRT to Cine-CAG, 0.96, and (3) the same size DSCAG images on negative and positive hard copies to Cine-CAG, 0.97. The semiautomatically measured values of 10 times enlarged DSCAG images on CRT and the manually measured values of the same size negative and positive DSCAG images in hard copy closely correlated with the values measured using Cine-CAG. When the liver was superimposed in the long-axis projection, the diagnostic capabilities of DSCAG and Cine-CAG were compared. The materials included 10 left coronary arteriograms and 11 right coronary arteriograms. Diagnostically, DSCAG was more useful than Cine-CAG in the long-axis projection. (author)

  20. Classification-based summation of cerebral digital subtraction angiography series for image post-processing algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Schuldhaus, D; Spiegel, M; Polyanskaya, M; Hornegger, J [Pattern Recognition Lab, University Erlangen-Nuremberg (Germany); Redel, T [Siemens AG Healthcare Sector, Forchheim (Germany); Struffert, T; Doerfler, A, E-mail: martin.spiegel@informatik.uni-erlangen.de [Department of Neuroradiology, University Erlangen-Nuremberg (Germany)

    2011-03-21

    X-ray-based 2D digital subtraction angiography (DSA) plays a major role in the diagnosis, treatment planning and assessment of cerebrovascular disease, i.e. aneurysms, arteriovenous malformations and intracranial stenosis. DSA information is increasingly used for secondary image post-processing such as vessel segmentation, registration and comparison to hemodynamic calculation using computational fluid dynamics. Depending on the amount of injected contrast agent and the duration of injection, these DSA series may not exhibit one single DSA image showing the entire vessel tree. The interesting information for these algorithms, however, is usually depicted within a few images. If these images would be combined into one image the complexity of segmentation or registration methods using DSA series would drastically decrease. In this paper, we propose a novel method automatically splitting a DSA series into three parts, i.e. mask, arterial and parenchymal phase, to provide one final image showing all important vessels with less noise and moving artifacts. This final image covers all arterial phase images, either by image summation or by taking the minimum intensities. The phase classification is done by a two-step approach. The mask/arterial phase border is determined by a Perceptron-based method trained from a set of DSA series. The arterial/parenchymal phase border is specified by a threshold-based method. The evaluation of the proposed method is two-sided: (1) comparison between automatic and medical expert-based phase selection and (2) the quality of the final image is measured by gradient magnitudes inside the vessels and signal-to-noise (SNR) outside. Experimental results show a match between expert and automatic phase separation of 93%/50% and an average SNR increase of up to 182% compared to summing up the entire series.

  1. A 2D driven 3D vessel segmentation algorithm for 3D digital subtraction angiography data

    Energy Technology Data Exchange (ETDEWEB)

    Spiegel, M; Hornegger, J [Pattern Recognition Lab, University Erlangen-Nuremberg, Erlangen (Germany); Redel, T [Siemens AG Healthcare Sector, Forchheim (Germany); Struffert, T; Doerfler, A, E-mail: martin.spiegel@informatik.uni-erlangen.de [Department of Neuroradiology, University Erlangen-Nuremberg, Erlangen (Germany)

    2011-10-07

    Cerebrovascular disease is among the leading causes of death in western industrial nations. 3D rotational angiography delivers indispensable information on vessel morphology and pathology. Physicians make use of this to analyze vessel geometry in detail, i.e. vessel diameters, location and size of aneurysms, to come up with a clinical decision. 3D segmentation is a crucial step in this pipeline. Although a lot of different methods are available nowadays, all of them lack a method to validate the results for the individual patient. Therefore, we propose a novel 2D digital subtraction angiography (DSA)-driven 3D vessel segmentation and validation framework. 2D DSA projections are clinically considered as gold standard when it comes to measurements of vessel diameter or the neck size of aneurysms. An ellipsoid vessel model is applied to deliver the initial 3D segmentation. To assess the accuracy of the 3D vessel segmentation, its forward projections are iteratively overlaid with the corresponding 2D DSA projections. Local vessel discrepancies are modeled by a global 2D/3D optimization function to adjust the 3D vessel segmentation toward the 2D vessel contours. Our framework has been evaluated on phantom data as well as on ten patient datasets. Three 2D DSA projections from varying viewing angles have been used for each dataset. The novel 2D driven 3D vessel segmentation approach shows superior results against state-of-the-art segmentations like region growing, i.e. an improvement of 7.2% points in precision and 5.8% points for the Dice coefficient. This method opens up future clinical applications requiring the greatest vessel accuracy, e.g. computational fluid dynamic modeling.

  2. Parametric color coding of digital subtraction angiography in the evaluation of carotid cavernous fistulas.

    Science.gov (United States)

    Gölitz, P; Struffert, T; Lücking, H; Rösch, J; Knossalla, F; Ganslandt, O; Deuerling-Zheng, Y; Doerfler, A

    2013-06-01

    Angiographic assessment of carotid cavernous fistulas (CCFs) can be complex. Our purpose was to examine whether the use of parametric color coding in the postprocessing of DSA series is advantageous in the evaluation of CCFs. We enrolled 16 patients with angiographically proven CCFs. Endovascular treatment was performed in 14 cases. For postprocessing of digital subtraction angiography (DSA) series, a newly implemented algorithm of parametric color coding was used, turning sequential images of two-dimensional (2D)-DSA series into a single color-coded image. Angiographic data of initial, interventional, and postinterventional 2D-DSA series were compared with color-coded images. Whether parametric color coding could facilitate evaluation of fistula architecture and provide a more precise estimation of fistula venous drainage patterns as well as whether flow analysis could reveal objective changes during and after treatment were investigated. In 56 % of the cases, parametric color coding was observed to facilitate visualization of fistula angioarchitecture. Estimation of fistula drainage flow patterns was considered to be improved in 31 % of the cases. For assessment of hemodynamic changes during and after treatment, parametric color coding was assumed to be helpful in 21 % of the cases, especially because revealing flow changes that were not visible on 2D-DSA series were now visible. Parametric color coding is a fast application tool that might provide additional support in the angiographic evaluation of CCFs. Visualization of complex fistula architecture could be facilitated, and flow analysis might improve assessment of venous drainage patterns, thereby increasing overall diagnostic confidence. During and after treatment, hemodynamic changes that were not visible on 2D-DSA series could now be depicted.

  3. A 2D driven 3D vessel segmentation algorithm for 3D digital subtraction angiography data

    International Nuclear Information System (INIS)

    Spiegel, M; Hornegger, J; Redel, T; Struffert, T; Doerfler, A

    2011-01-01

    Cerebrovascular disease is among the leading causes of death in western industrial nations. 3D rotational angiography delivers indispensable information on vessel morphology and pathology. Physicians make use of this to analyze vessel geometry in detail, i.e. vessel diameters, location and size of aneurysms, to come up with a clinical decision. 3D segmentation is a crucial step in this pipeline. Although a lot of different methods are available nowadays, all of them lack a method to validate the results for the individual patient. Therefore, we propose a novel 2D digital subtraction angiography (DSA)-driven 3D vessel segmentation and validation framework. 2D DSA projections are clinically considered as gold standard when it comes to measurements of vessel diameter or the neck size of aneurysms. An ellipsoid vessel model is applied to deliver the initial 3D segmentation. To assess the accuracy of the 3D vessel segmentation, its forward projections are iteratively overlaid with the corresponding 2D DSA projections. Local vessel discrepancies are modeled by a global 2D/3D optimization function to adjust the 3D vessel segmentation toward the 2D vessel contours. Our framework has been evaluated on phantom data as well as on ten patient datasets. Three 2D DSA projections from varying viewing angles have been used for each dataset. The novel 2D driven 3D vessel segmentation approach shows superior results against state-of-the-art segmentations like region growing, i.e. an improvement of 7.2% points in precision and 5.8% points for the Dice coefficient. This method opens up future clinical applications requiring the greatest vessel accuracy, e.g. computational fluid dynamic modeling.

  4. Decreasing radiation doses in digital subtraction angiographies consecutively performed by trainees

    International Nuclear Information System (INIS)

    Xu, G.; Zhao, W.; Zheng, L.; Fan, X.; Yin, Q.; Liu, X.

    2012-01-01

    Digital subtraction angiography (DSA) performed by trainees may be related to increased radiation exposure. This study was aimed to investigate and quantify this learning effect, with fluoroscopy time and dose-area product (DAP) as parameters. We collected procedure data of the first to the fortieth cerebral DSA consecutively performed by 13 trainees in a training centre. DAP, procedure time, fluoroscopy time, number of cine-frames of the first 20 DSA procedures performed by these trainees were compared with that of the second 20 procedures. There was no significant difference concerning the procedure time between the first and the second 20 procedures (56.3 ±29.5 vs 51.5±20.2 min, p = 0.113). Numbers of cine-frames were very similar between the first and the second 20 procedures (750.7 ±290.3 vs 744.5 ±188.7, p = 0.830). Fluoroscopy time of the first 20 procedures was significantly longer than that of the second 20 procedures (17.8 ±15.4 vs 12.6 ±9.0, p = 0.001). DAP of the first 20 procedures was significantly higher than that of the second 20 procedures (6.4 ±4.9 vs 3.8 ±1.8, p < 0.001). DAP was correlated significantly with the performer's experience (R = -0.288, p < 0.001). There exists a learning effect of radiation exposure during cerebral DSA procedures performed by trainees. The learning effect is significant during the first 20 procedures, and becomes insignificant after 20 procedures. Insufficient catheter skills in novice trainees may be one reason for this effect. (authors)

  5. Follow-up after embolization of ruptured intracranial aneurysms: a prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography.

    Science.gov (United States)

    Serafin, Zbigniew; Strześniewski, Piotr; Lasek, Władysław; Beuth, Wojciech

    2012-11-01

    To prospectively compare of the diagnostic value of digital subtraction angiography (DSA) and time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. Seventy-two consecutive patients were examined 3 months after the embolization. The index tests included: two-dimensional DSA (2D-DSA), three-dimensional DSA (3D-DSA), and TOF-MRA. The reference test was a retrospective consensus between 2D-DSA images, 3D-DSA images, and source rotational DSA images. The evaluation included: detection of the residual flow, quantification of the flow, and validity of the decision regarding retreatment. Intraobserver agreement and interobserver agreement were determined. The sensitivity and specificity of residual flow detection ranged from 84.6 % (2D-DSA and TOF-MRA) to 92.3 % (3D-DSA) and from 91.3 % (TOF-MRA) to 97.8 % (3D-DSA), respectively. The accuracy of occlusion degree evaluation ranged from 0.78 (2D-DSA) to 0.92 (3D-DSA, Cohen's kappa). The 2D-DSA method presented lower performance in the decision on retreatment than 3D-DSA (P < 0.05, ROC analysis). The intraobserver agreement was very good for all techniques (κ = 0.80-0.97). The interobserver agreement was moderate for TOF-MRA and very good for 2D-DSA and 3D-DSA (κ = 0.72-0.94). Considering the invasiveness of DSA and the minor difference in the diagnostic performance between 3D-DSA and TOF-MRA, the latter method should be the first-line modality for follow-up after aneurysm embolization.

  6. Follow-up after embolization of ruptured intracranial aneurysms: A prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography

    International Nuclear Information System (INIS)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw; Beuth, Wojciech

    2012-01-01

    To prospectively compare of the diagnostic value of digital subtraction angiography (DSA) and time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. Seventy-two consecutive patients were examined 3 months after the embolization. The index tests included: two-dimensional DSA (2D-DSA), three-dimensional DSA (3D-DSA), and TOF-MRA. The reference test was a retrospective consensus between 2D-DSA images, 3D-DSA images, and source rotational DSA images. The evaluation included: detection of the residual flow, quantification of the flow, and validity of the decision regarding retreatment. Intraobserver agreement and interobserver agreement were determined. The sensitivity and specificity of residual flow detection ranged from 84.6 % (2D-DSA and TOF-MRA) to 92.3 % (3D-DSA) and from 91.3 % (TOF-MRA) to 97.8 % (3D-DSA), respectively. The accuracy of occlusion degree evaluation ranged from 0.78 (2D-DSA) to 0.92 (3D-DSA, Cohen's kappa). The 2D-DSA method presented lower performance in the decision on retreatment than 3D-DSA (P < 0.05, ROC analysis). The intraobserver agreement was very good for all techniques (κ = 0.80-0.97). The interobserver agreement was moderate for TOF-MRA and very good for 2D-DSA and 3D-DSA (κ = 0.72-0.94). Considering the invasiveness of DSA and the minor difference in the diagnostic performance between 3D-DSA and TOF-MRA, the latter method should be the first-line modality for follow-up after aneurysm embolization. (orig.)

  7. Follow-up after embolization of ruptured intracranial aneurysms: A prospective comparison of two-dimensional digital subtraction angiography, three-dimensional digital subtraction angiography, and time-of-flight magnetic resonance angiography

    Energy Technology Data Exchange (ETDEWEB)

    Serafin, Zbigniew; Strzesniewski, Piotr; Lasek, Wladyslaw [Nicolaus Copernicus University, Collegium Medicum, Department of Radiology and Diagnostic Imaging, Bydgoszcz (Poland); Beuth, Wojciech [Nicolaus Copernicus University, Collegium Medicum, Department of Neurosurgery and Neurotraumatology, Bydgoszcz (Poland)

    2012-11-15

    To prospectively compare of the diagnostic value of digital subtraction angiography (DSA) and time-of-flight magnetic resonance angiography (TOF-MRA) in the follow-up of intracranial aneurysms after endovascular treatment. Seventy-two consecutive patients were examined 3 months after the embolization. The index tests included: two-dimensional DSA (2D-DSA), three-dimensional DSA (3D-DSA), and TOF-MRA. The reference test was a retrospective consensus between 2D-DSA images, 3D-DSA images, and source rotational DSA images. The evaluation included: detection of the residual flow, quantification of the flow, and validity of the decision regarding retreatment. Intraobserver agreement and interobserver agreement were determined. The sensitivity and specificity of residual flow detection ranged from 84.6 % (2D-DSA and TOF-MRA) to 92.3 % (3D-DSA) and from 91.3 % (TOF-MRA) to 97.8 % (3D-DSA), respectively. The accuracy of occlusion degree evaluation ranged from 0.78 (2D-DSA) to 0.92 (3D-DSA, Cohen's kappa). The 2D-DSA method presented lower performance in the decision on retreatment than 3D-DSA (P < 0.05, ROC analysis). The intraobserver agreement was very good for all techniques ({kappa} = 0.80-0.97). The interobserver agreement was moderate for TOF-MRA and very good for 2D-DSA and 3D-DSA ({kappa} = 0.72-0.94). Considering the invasiveness of DSA and the minor difference in the diagnostic performance between 3D-DSA and TOF-MRA, the latter method should be the first-line modality for follow-up after aneurysm embolization. (orig.)

  8. Automatic flow analysis of digital subtraction angiography using independent component analysis in patients with carotid stenosis.

    Directory of Open Access Journals (Sweden)

    Han-Jui Lee

    Full Text Available Current time-density curve analysis of digital subtraction angiography (DSA provides intravascular flow information but requires manual vasculature selection. We developed an angiographic marker that represents cerebral perfusion by using automatic independent component analysis.We retrospectively analyzed the data of 44 patients with unilateral carotid stenosis higher than 70% according to North American Symptomatic Carotid Endarterectomy Trial criteria. For all patients, magnetic resonance perfusion (MRP was performed one day before DSA. Fixed contrast injection protocols and DSA acquisition parameters were used before stenting. The cerebral circulation time (CCT was defined as the difference in the time to peak between the parietal vein and cavernous internal carotid artery in a lateral angiogram. Both anterior-posterior and lateral DSA views were processed using independent component analysis, and the capillary angiogram was extracted automatically. The full width at half maximum of the time-density curve in the capillary phase in the anterior-posterior and lateral DSA views was defined as the angiographic mean transient time (aMTT; i.e., aMTTAP and aMTTLat. The correlations between the degree of stenosis, CCT, aMTTAP and aMTTLat, and MRP parameters were evaluated.The degree of stenosis showed no correlation with CCT, aMTTAP, aMTTLat, or any MRP parameter. CCT showed a strong correlation with aMTTAP (r = 0.67 and aMTTLat (r = 0.72. Among the MRP parameters, CCT showed only a moderate correlation with MTT (r = 0.67 and Tmax (r = 0.40. aMTTAP showed a moderate correlation with Tmax (r = 0.42 and a strong correlation with MTT (r = 0.77. aMTTLat also showed similar correlations with Tmax (r = 0.59 and MTT (r = 0.73.Apart from vascular anatomy, aMTT estimates brain parenchyma hemodynamics from DSA and is concordant with MRP. This process is completely automatic and provides immediate measurement of quantitative peritherapeutic brain parenchyma

  9. Multi-slice CT for visualization of acute pulmonary embolism: single breath-hold subtraction technique

    Energy Technology Data Exchange (ETDEWEB)

    Wildberger, J.E.; Mahnken, A.H.; Spuentrup, E.; Guenther, R.W. [Dept. of Diagnostic Radiology, Univ. of Technology, Aachen (Germany); Klotz, E.; Ditt, H. [Siemens Medical Solutions, Computed Tomography, Forchheim (Germany)

    2005-01-01

    Purpose: the purpose of our preliminary animal study was to evaluate the feasibility of a new subtraction technique for visualization of perfusion defects within the lung parenchyma in segmental and subsegmental pulmonary embolism (PE). Materials and methods: in three healthy pigs, PE were artificially induced by fresh human clot material. Within a single breath-hold, CT angiography (CTA) was performed on a 16-slice multi-slice CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 mL of contrast-medium, followed by a saline chaser. Scan parameters were 120 kV and 100 mAs{sub eff.}, using a collimation of 16 x 1.5 mm and a table speed/rot. of 36 mm (pitch: 1.5; rotation time: 0.5 s). A new 3D subtraction technique was developed, which is based on automated segmentation, non-linear spatial filtering and non-rigid registration. Data were analysed using a color-encoded ''compound view'' of parenchymal enhancement and CTA information displayed in axial, coronal and sagittal orientation. Results: subtraction was technically feasible in all three data sets. The mean scan time for each series was 4.7 s, interscan delay was 14.7 s, respectively. Therefore, an average breath-hold of approximately 24 s was required for the overall scanning procedure. Downstream of occluded segmental and subsegmental arteries, perfusion defects were clearly assessable, showing lower or missing enhancement compared to normally perfused lung parenchyma. In all pigs, additional peripheral areas with triangular shaped perfusion defects were delineated, considered typical for PE. Conclusions: our initial results from the animal model studied slow that perfusion imaging of PE is feasible within a single breath-hold. It allows a comprehensive assessment of perfusion deficits as the direct proof of a pulmonary embolus, can be combined with an indirect visual quantification of the density changes in the adjacent lung tissue

  10. Baseline subtraction technique in the frequency-wavenumber domain for high sensitivity damage detection.

    Science.gov (United States)

    McKeon, Peter; Yaacoubi, Slah; Declercq, Nico F; Ramadan, Salah; Yaacoubi, Weina K

    2014-02-01

    This paper suggests a method for high-sensitivity damage detection. The method is based on pitch-catch measurements of Lamb waves combined with a baseline subtraction technique in the frequency-wavenumber domain. Small amplitude converted modes, generated during the interaction of propagating waves with damage, can thus be detected with minimal a priori information regarding their expected location in the frequency-wavenumber plane. This method is applied in the present paper to a case of notches with varied depth. Finite element simulations are carried out in the temporal domain to mimic results obtainable in real-world experiments. Two cases are studied, namely when each of the two pure fundamental modes are incident on a notch. The advantages of the method are detailed. The procedure to implement this method is described in the context of Structural Health Monitoring (SHM) or Non-Destructive Testing (NDT). Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Simultaneous optical digital half-subtraction and -addition using SOAs and a PPLN waveguide.

    Science.gov (United States)

    McGeehan, John E; Kumar, Saurabh; Willner, Alan E

    2007-04-30

    We demonstrate an optical half-subtracter and half-adder module that performs simultaneous bit-wise subtraction and addition of two 5 Gbit/s RZ data streams. We generate Borrow (/X*Y) and Difference/Sum (X plus sign in circleY, or XOR) outputs using cross-gain modulation (XGM) in two parallel SOAs. Taking advantage of the gain saturation inherent to SOAs, we generate two signals, /X*Y, and X*/Y, and combine them using a passive optical coupler to generate the XOR Difference/Sum output. We use difference-frequency-generation-based lambda-conversion in a PPLN waveguide to generate the Carry (X*Y) output. The PPLN waveguide allows bit-synchronous wavelength shifting, is wide-bandwidth, and offers no intrinsic chirp. Our module uses three active elements to perform simultaneous half-subtraction and addition, and carries a maximum power penalty of 1.0 dB.

  12. Intra-Arterial MR Perfusion Imaging of Meningiomas: Comparison to Digital Subtraction Angiography and Intravenous MR Perfusion Imaging.

    Directory of Open Access Journals (Sweden)

    Mark A Lum

    Full Text Available To evaluate the ability of IA MR perfusion to characterize meningioma blood supply.Studies were performed in a suite comprised of an x-ray angiography unit and 1.5T MR scanner that permitted intraprocedural patient movement between the imaging modalities. Patients underwent intra-arterial (IA and intravenous (IV T2* dynamic susceptibility MR perfusion immediately prior to meningioma embolization. Regional tumor arterial supply was characterized by digital subtraction angiography and classified as external carotid artery (ECA dural, internal carotid artery (ICA dural, or pial. MR perfusion data regions of interest (ROIs were analyzed in regions with different vascular supply to extract peak height, full-width at half-maximum (FWHM, relative cerebral blood flow (rCBF, relative cerebral blood volume (rCBV, and mean transit time (MTT. Linear mixed modeling was used to identify perfusion curve parameter differences for each ROI for IA and IV MR imaging techniques. IA vs. IV perfusion parameters were also directly compared for each ROI using linear mixed modeling.18 ROIs were analyzed in 12 patients. Arterial supply was identified as ECA dural (n = 11, ICA dural (n = 4, or pial (n = 3. FWHM, rCBV, and rCBF showed statistically significant differences between ROIs for IA MR perfusion. Peak Height and FWHM showed statistically significant differences between ROIs for IV MR perfusion. RCBV and MTT were significantly lower for IA perfusion in the Dural ECA compared to IV perfusion. Relative CBF in IA MR was found to be significantly higher in the Dural ICA region and MTT significantly lower compared to IV perfusion.

  13. Image processing techniques for digital orthophotoquad production

    Science.gov (United States)

    Hood, Joy J.; Ladner, L. J.; Champion, Richard A.

    1989-01-01

    Orthophotographs have long been recognized for their value as supplements or alternatives to standard maps. Recent trends towards digital cartography have resulted in efforts by the US Geological Survey to develop a digital orthophotoquad production system. Digital image files were created by scanning color infrared photographs on a microdensitometer. Rectification techniques were applied to remove tile and relief displacement, thereby creating digital orthophotos. Image mosaicking software was then used to join the rectified images, producing digital orthophotos in quadrangle format.

  14. Digital subtraction radiographic analysis of the combination of bioabsorbable membrane and bovine morphogenetic protein pool in human periodontal infrabony defects

    Directory of Open Access Journals (Sweden)

    Maria do Carmo Machado Guimarães

    2010-08-01

    Full Text Available OBJECTIVES: This study assessed the bone density gain and its relationship with the periodontal clinical parameters in a case series of a regenerative therapy procedure. MATERIAL AND METHODS: Using a split-mouth study design, 10 pairs of infrabony defects from 15 patients were treated with a pool of bovine bone morphogenetic proteins associated with collagen membrane (test sites or collagen membrane only (control sites. The periodontal healing was clinically and radiographically monitored for six months. Standardized pre-surgical and 6-month postoperative radiographs were digitized for digital subtraction analysis, which showed relative bone density gain in both groups of 0.034 ± 0.423 and 0.105 ± 0.423 in the test and control group, respectively (p>0.05. RESULTS: As regards the area size of bone density change, the influence of the therapy was detected in 2.5 mm² in the test group and 2 mm² in the control group (p>0.05. Additionally, no correlation was observed between the favorable clinical results and the bone density gain measured by digital subtraction radiography (p>0.05. CONCLUSIONS: The findings of this study suggest that the clinical benefit of the regenerative therapy observed did not come with significant bone density gains. Long-term evaluation may lead to a different conclusions.

  15. [X-ray semiotics of sialolithiasis in functional digital subtraction sialography].

    Science.gov (United States)

    Iudin, L A; Kondrashin, S A; Afanas'ev, V V; Shchipskiĭ, A V

    1995-01-01

    Twenty-seven patients with sialolithiasis were examined using functional subtraction sialography developed by the authors. Differential diagnostic signs characterizing the degree of involvement of the salivary gland were defined. High efficacy of the method helps correctly plan the treatment strategy.

  16. Visualization of the renal venous system by renal arteriography with digital subtraction angiography

    International Nuclear Information System (INIS)

    Nagai, Jun

    1989-01-01

    The purpose of this study was to obtain vivid and precise images of intrarenal venous branching using DSA for renal arteriography. The type of system used was an ADAC DPS-4100C with 70-80 kVp, and 320 mA, 25-50 msec at 6 frames/sec. The duration was 10 sec and the matrix size was 512x512. In order to retain clear subtracted images of intrarenal venous branching with minimal noise the three frames were selected on the time-density curve of DSA: (Fig.3). 1) a frame on which renal arteries disappear (frame X), 2) the frame with highest renal venous density value as (frame Y), 3) the difference of the nephrogram density between X and Y frames in which only the density of the nephrogram decreases (frame Z). The mask image is the image subtracted by the equation of the weighted averaging method on X and Z frame and is subtracted from the image of Y frame in the final step. By this method, 40 kidneys in 36 patients were studied, and the intrarenal venous branches up to the interlobar vein was clearly demonstrated in 28 of these cases (70%). This method is useful to estimate the extent of intrarenal lesions and detect abnormal renal blood flow compared with conventional temporal subtraction method. (author)

  17. Digital watermarking techniques and trends

    CERN Document Server

    Nematollahi, Mohammad Ali; Rosales, Hamurabi Gamboa

    2017-01-01

    This book presents the state-of-the-arts application of digital watermarking in audio, speech, image, video, 3D mesh graph, text, software, natural language, ontology, network stream, relational database, XML, and hardware IPs. It also presents new and recent algorithms in digital watermarking for copyright protection and discusses future trends in the field. Today, the illegal manipulation of genuine digital objects and products represents a considerable problem in the digital world. Offering an effective solution, digital watermarking can be applied to protect intellectual property, as well as fingerprinting, enhance the security and proof-of-authentication through unsecured channels.

  18. Tests of variable-band multilayers designed for investigating optimal signal-to-noise vs artifact signal ratios in Dual-Energy Digital Subtraction Angiography (DDSA) imaging systems

    International Nuclear Information System (INIS)

    Boyers, D.; Ho, A.; Li, Q.; Piestrup, M.; Rice, M.; Tatchyn, R.

    1993-08-01

    In recent work, various design techniques were applied to investigate the feasibility of controlling the bandwidth and bandshape profiles of tungsten/boron-carbon (W/B 4 C) and tungsten/silicon (W/Si) multilayers for optimizing their performance in synchrotron radiation based angiographical imaging systems at 33 keV. Varied parameters included alternative spacing geometries, material thickness ratios, and numbers of layer pairs. Planar optics with nominal design reflectivities of 30%--94% and bandwidths ranging from 0.6%--10% were designed at the Stanford Radiation Laboratory, fabricated by the Ovonic Synthetic Materials Company, and characterized on Beam Line 4-3 at the Stanford Synchrotron Radiation Laboratory, in this paper we report selected results of these tests and review the possible use of the multilayers for determining optimal signal to noise vs. artifact signal ratios in practical Dual-Energy Digital Subtraction Angiography systems

  19. Computer processing techniques in digital radiography research

    International Nuclear Information System (INIS)

    Pickens, D.R.; Kugel, J.A.; Waddill, W.B.; Smith, G.D.; Martin, V.N.; Price, R.R.; James, A.E. Jr.

    1985-01-01

    In the Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, and the Center for Medical Imaging Research, Nashville, TN, there are several activities which are designed to increase the information available from film-screen acquisition as well as from direct digital acquisition of radiographic information. Two of the projects involve altering the display of images after acquisition, either to remove artifacts present as a result of the acquisition process or to change the manner in which the image is displayed to improve the perception of details in the image. These two projects use methods which can be applied to any type of digital image, but are being implemented with images digitized from conventional x-ray film. One of these research endeavors involves mathematical alteration of the image to correct for motion artifacts or registration errors between images that will be subtracted. Another applies well-known image processing methods to digital radiographic images to improve the image contrast and enhance subtle details in the image. A third project involves the use of dual energy imaging with a digital radiography system to reconstruct images which demonstrate either soft tissue details or the osseous structures. These projects are discussed in greater detail in the following sections of this communication

  20. Visualization of μ1 opiate receptors in rat brain by using a computerized autoradiographic subtraction technique

    International Nuclear Information System (INIS)

    Goodman, R.R.; Pasternak, G.W.

    1985-01-01

    The authors have developed a quantitative computerized subtraction technique to demonstrate in rat brain the regional distribution of μ 1 sites, a common very-high-affinity binding site for both morphine and the enkephalins. Low concentrations of [D-Ala 2 , D-Leu 5 ]enkephalin selectively inhibit the μ 1 binding of [ 3 H]dihydromorphine, leaving μ 2 -sites, while low morphine concentrations eliminate the μ 1 binding of [ 3 H][D-Ala 2 , D-Leu 5 ]enkephalin, leaving sigma sites. Thus, quantitative differences between images of sections incubated in the presence and absence of these low concentrations of unlabeled opioid represent μ 1 binding sites. The regional distributions of μ 1 sites labeled with [ 3 H]dihydromorphine were quite similar to those determined by using [ 3 H][D-Ala 2 , D-Leu 5 ]enkephalin. High levels of μ 1 binding were observed in the periaqueductal gray, medial thalamus, and median raphe, consistent with the previously described role of μ 1 sites in analgesia. Other regions with high levels of μ 1 binding include the nucleus accumbens, the clusters and subcallosal streak of the striatum, hypothalamus, medial habenula, and the medial septum/diagonal band region. The proportion of total specific binding corresponding to μ 1 sites varied among the regions, ranging from 14% to 75% for [ 3 H][D-Ala 2 , D-Leu 5 ]enkephalin and 20% to 52% for [ 3 H]dihydromorphine

  1. Carbon dioxide digital subtraction angiography using a new gas management system; Digitale Subtraktionsangiographie mit Kohlendioxid unter Verwendung eines neuen Gasdosiersystems

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz-Rode, T.; Alzen, G.; Guenther, R.W. [Klinik fuer Radiologische Diagnostik, Universitaetsklinikum der RWTH Aachen (Germany)

    1997-07-01

    Purpose: The clinical evaluation of digital subtraction angiography with carbon dioxide using a newly developed low-tech CO{sub 2}-dosage- and injection system. Method and patients: The hand-held system (CO{sub 2} angio set) consists of a dosage chamber in connection with a special stopcock to apportion the gas. By optimising injection volume and pressure steady gas flow characteristics are approximated. A safety design prevents unintentional gas injection volume and pressure steady gas flow characteristics are approximated. A safety design prevents unintentional gas injection. CO{sub 2} arteriographies were performed on 185 patients. Main indications were renal insufficiency and a history of adverse reactions to iodinated contrast media. In patients with femoral connula access, catheterless reflux angiography was performed. Results: The injection system provided complete and coherent visualisation of the abdominal aorta, visceral, pelvic, and lower limb arteries via catheter (71 cases) or via femoral cannula using reflux technique (114 cases). Stenoses, occlusions, and collaterals were assessable. Employing the gas reflux over the aortic bifurcation bilateral run-off studies up to the calf trifurcation were performed via unilateral femoral cannula. Use of a dedicated stacking software improved image quality of distal femoral, popliteal and calf arteries. Conclusion: The CO{sub 2} management system allows adequate imaging of the arteries below the diaphragm. Ease and safety of use and low costs are advantageous. (orig.) [Deutsch] Ziel: Die klinische Erprobung der digitalen Subtraktionsangiographie mit Kohlendioxid unter Verwendung eines neuentwickelten, einfachen Gasdosier- und Injektionssystems. Methode und Patienten: Eine Dosierkammer mit einstellbarem Volumen in Verbindung mit einem Spezial-Hahn (CO{sub 2}-Angio-Set) portioniert das Gas. Durch Optimierung von Injektionsvolumen und -druck wurde eine konstante Ausstroemcharakteristik angenaehert. Das System wurde

  2. Pulmonary arteriography by digital subtraction angiographic method in cyanotic heart disease with pulmonary stenosis or pulmonary atresia

    International Nuclear Information System (INIS)

    Kobayashi, Junjiro; Hirose, Hajime; Nakano, Susumu

    1985-01-01

    Pulmonary arteriography was performed by digital subtraction angiographic (DSA) method in 10 patients with cyanotic heart disease associated with pulmonary stenosis or pulmonary atresia. Ten patients consisted of five patients with tetralogy of Fallot, three with single ventricle and pulmonary stenosis, and two with pseudotruncus arteriosus. Hepato-clavicular position was taken in four patients. Pulmonary artery and its main branches were opacified and recognized clearly, and their diameter could be measured accurately with a small amount of contrast medium. There was a good correlation between the diameter of pulmonary artery measured by DSA and that measured by conventional pulmonary arteriography. DSA is a useful method for evaluating the size and the stenosis of pulmonary artery especially in small cyanotic infants. (author)

  3. Influence of homeopathic treatment with comfrey on bone density around titanium implants: a digital subtraction radiography study in rats.

    Science.gov (United States)

    Sakakura, Celso Eduardo; Neto, Rubens Spin; Bellucci, Marina; Wenzel, Ann; Scaf, Gulnara; Marcantonio, Elcio

    2008-06-01

    The objective of this study was to evaluate the influence of homeopathic treatment with comfrey (Shymphytum officinalis 6CH) on radiographic bone density and area around titanium implants. Forty-eight rats were divided into two groups of 24 animals each: a control group (C) and a test group (SO). Each animal received one titanium micro-implant placed in the tibia. The animals in Group SO were subjected to 10 drops of comfrey 6CH per day mixed into their drinking water until the day of sacrifice. Eight animals of each group were sacrificed at 7, 14 and 28 days post-surgery, respectively. Standardized digital radiographs were obtained on the day of implant installation (baseline images) and on the day of sacrifice (final images). Digital subtraction of the two corresponding images was performed to evaluate changes in bone density and the area related to change around the implant between baseline and final images. Subtraction images demonstrated that a significant difference existed in mean shade of gray at 14 days post-surgery between Group SO (mean 175.3+/-14.4) and Group C (mean 146.2+/-5.2). Regarding the area in pixels corresponding to the bone gain in Group SO, the differences observed between the sacrifice periods and groups were only significant at 7 days sacrifice between Group SO (mean 171.2+/-21.9) and Group C (mean 64.5+/-60.4). Within the limits of this study, comfrey administration promotes an increase in radiographic bone density around titanium implants in the initial period of bone healing.

  4. Temporal Subtraction of Digital Breast Tomosynthesis Images for Improved Mass Detection

    National Research Council Canada - National Science Library

    Li, Christina M

    2007-01-01

    Digital breast tomosynthesis (DBT) strives to overcome the obstacles presented in conventional 2D mammography by taking multiple projections over a fixed angle and reconstructing volumetric data isolates overlying anatomy...

  5. A single injection technique for subtraction of blood background in 131I-hippuran renograms

    International Nuclear Information System (INIS)

    Rutland, M.D.

    1979-01-01

    A method of subtracting blood background during probe-renography is presented which does not require a prior injection of RIHSA and which produces results approximately 11% higher than the RIHSA method. The new method treats the renogram up to two-and-a-half minutes as a combination of a fraction of the blood curve and a fraction of the integral of the blood curve. Analysis of the data, using either a computer or a programmed calculator, enables these two fractions to be calculated, hence producing the 'background subtraction factor' and the 'uptake constant'. (author)

  6. Diagnostic yield and accuracy of CT angiography, MR angiography, and digital subtraction angiography for detection of macrovascular causes of intracerebral haemorrhage: Prospective, multicentre cohort study

    NARCIS (Netherlands)

    C.J.J. Van Asch (Charlotte J.J.); B.K. Velthuis (Birgitta K.); G.J.E. Rinkel (Gabriël J.E.); A. Algra (Ale); G.A.P. de Kort (G. A P); T.D. Witkamp (Theo); J.C.M. De Ridder (Johanna C.M.); K.M. Van Nieuwenhuizen (Koen M.); F.-E. De Leeuw (Frank-Erik); W.J. Schonewille (Wouter); P.L.M. de Kort (Paul); D.W.J. Dippel (Diederik); T.W.M. Raaymakers (Theodora W.M.); J. Hofmeijer; M.J.H. Wermer (Marieke); H. Kerkhoff (Henk); K. Jellema (Korné); I.M. Bronner (Irene M.); M.J.M. Remmers (Michel ); H.P. Bienfait (Henri); R.J.G.M. Witjes (Ron J.G.M.); J.P. Greving (Jacoba); C.J.M. Klijn (Catharina J.M.); H.F. de Leeuw (Frank); H.B. Boogaarts; E.J. van Dijk (Ewoud); W.J. Schonewille; W.M.J. Pellikaan; C. Puppels-De Waard; P.L.M. De Kort; J.P. Peluso; J. van Tuijl (Jordie); J. Hofmeijer; F.B.M. Joosten (Frank); D.W.J. Dippel (Diederik); L. Khajeh (Ladbon); T.W.M. Raaijmakers; M.J. Wermer; M.A.A. van Walderveen (Marianne); H. Kerkhoff; E. Zock; K. Jellema (Korné); G.J. Lycklama à Nijeholt (Geert); I.M. Bronner; M.J.M. Remmers; R.J.G.M. Witjes; H.P. Bienfait; K.E. Droogh-Greve; R. Donders (Rogier); V.I.H. Kwa; T.H.C.M.L. Schreuder (Tobien H. C. M. L.); C.L. Franke (Cees); J.S. Straver; C. Jansen; S.L.M. Bakker (Stef); C.C. Pleiter (C.); M.C. Visser; C.J.J. Van Asch; B.K. Velthuis (Birgitta); G.J.E. Rinkel (Gabriel); K.M. Van Nieuwenhuizen; C.J.M. Klijn (Catharina J.M.)

    2015-01-01

    textabstractStudy question What are the diagnostic yield and accuracy of early computed tomography (CT) angiography followed by magnetic resonance imaging/angiography (MRI/MRA) and digital subtraction angiography (DSA) in patients with non-traumatic intracerebral haemorrhage? Methods This

  7. Cost-Effectiveness of Magnetic Resonance Angiography Versus Intra-arterial Digital Subtraction Angiography to Follow-Up Patients With Coiled Intracranial Aneurysms

    NARCIS (Netherlands)

    Schaafsma, Joanna D.; Koffijberg, Hendrik; Buskens, Erik; Velthuis, Birgitta K.; van der Graaf, Yolanda; Rinkel, Gabriel J. E.

    Background and Purpose-To follow up patients with coiled intracranial aneurysms, magnetic resonance angiography (MRA) is a promising noninvasive alternative to current standard intra-arterial digital subtraction angiography (IA-DSA). MRA test results do not always concord with those of IA-DSA, and

  8. Cost-effectiveness of magnetic resonance angiography versus intra-arterial digital subtraction angiography to follow-up patients with coiled intracranial aneurysms

    NARCIS (Netherlands)

    Schaafsma, Joanna D.; Koffijberg, Hendrik; Buskens, Erik; Velthuis, Birgitta K.; van der Graaf, Yolanda; Rinkel, Gabriël J.E.

    Background and Purpose-: To follow up patients with coiled intracranial aneurysms, magnetic resonance angiography (MRA) is a promising noninvasive alternative to current standard intra-arterial digital subtraction angiography (IA-DSA). MRA test results do not always concord with those of IA-DSA, and

  9. Evaluation of the rockburst potential in longwall coal mining using passive seismic velocity tomography and image subtraction technique

    Science.gov (United States)

    Hosseini, Navid

    2017-09-01

    Rockburst is a typical dynamic disaster in underground coal mines which its occurrences relate to the mechanical quality of coal seam and surrounding rock mass and also the condition of stress distribution. The main aim of this paper is to study the potential of rockburst in a longwall coal mine by using of passive seismic velocity tomography and image subtraction technique. For this purpose, first by mounting an array of receivers on the surface above the active panel, the mining-induced seismic data as a passive source for several continuous days were recorded. Then, the three-dimensional tomograms using simultaneous iteration reconstruction technique (SIRT) for each day are created and by employing the velocity filtering, the overstressed zones are detected. In addition, the two-dimensional seismic velocity tomograms in coal seam level by slicing the three-dimensional tomograms are obtained. Then the state of stress changes in successive days by applying the image subtraction technique on these two-dimensional tomograms is considered. The results show that the compilation of filtered three-dimensional tomograms and subtracted images is an appropriate approach for detecting the overstressed zones around the panel and subsequent evaluation of rockburst potential. The research conclusion proves that the applied approach in this study in combination with field observations of rock mass status can effectively identify the rockburst-prone areas during the mining operation and help to improve the safety condition.

  10. A feasibility study of projection-based energy weighting based on a photon-counting detector in contrast-enhanced digital subtraction mammography: a simulation study

    International Nuclear Information System (INIS)

    Choi, Sunghoon; Lee, Seungwan; Choi, Yuna; Kim, Heejoung

    2014-01-01

    Contrast media, such as iodine and gadolinium, are generally used in digital subtraction mammography to enhance the contrast between target and background materials. In digital subtraction mammography, where one image (with contrast medium) is subtracted from another (anatomical background) to facilitate visualization of the tumor structure, tumors can be more easily distinguished after the injection of a contrast medium. In order to have more an effective method to increase the contrast-to-noise ratio (CNR), we applied a projection-based energy-weighting method. The purpose of this study is to demonstrate the feasibility of using the projection-based energy-weighting method in digital subtraction mammography. Unlike some other previous studies, we applied the projection-based energy-weighting method to more practical mammography conditions by using the Monte Carlo method to simulate four different iodine solutions embedded in a breast phantom comprised of 50% adipose and 50% glandular tissues. We also considered an optimal tube voltage and anode/filter combination in digital iodine contrast media mammography in order to maximize the figure-of-merit (FOM). The simulated source energy was from 20 to 45 keV to prevent electronic noise and include the k-edge energy of iodine (33.2 keV). The results showed that the projection-based energy-weighting improved the CNR by factors of 1.05 - 1.86 compared to the conventionally integrated images. Consequently, the CNR of digital subtraction mammography images can be improved by using projection-based energy-weighting with photon-counting detectors.

  11. A feasibility study of projection-based energy weighting based on a photon-counting detector in contrast-enhanced digital subtraction mammography: a simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Sunghoon; Lee, Seungwan; Choi, Yuna; Kim, Heejoung [Yonsei University, Wonju (Korea, Republic of)

    2014-06-15

    Contrast media, such as iodine and gadolinium, are generally used in digital subtraction mammography to enhance the contrast between target and background materials. In digital subtraction mammography, where one image (with contrast medium) is subtracted from another (anatomical background) to facilitate visualization of the tumor structure, tumors can be more easily distinguished after the injection of a contrast medium. In order to have more an effective method to increase the contrast-to-noise ratio (CNR), we applied a projection-based energy-weighting method. The purpose of this study is to demonstrate the feasibility of using the projection-based energy-weighting method in digital subtraction mammography. Unlike some other previous studies, we applied the projection-based energy-weighting method to more practical mammography conditions by using the Monte Carlo method to simulate four different iodine solutions embedded in a breast phantom comprised of 50% adipose and 50% glandular tissues. We also considered an optimal tube voltage and anode/filter combination in digital iodine contrast media mammography in order to maximize the figure-of-merit (FOM). The simulated source energy was from 20 to 45 keV to prevent electronic noise and include the k-edge energy of iodine (33.2 keV). The results showed that the projection-based energy-weighting improved the CNR by factors of 1.05 - 1.86 compared to the conventionally integrated images. Consequently, the CNR of digital subtraction mammography images can be improved by using projection-based energy-weighting with photon-counting detectors.

  12. A quantitative study of bone repair after endodontic therapy on digital subtraction radiography

    International Nuclear Information System (INIS)

    Kim, Jae Duk

    1997-01-01

    This study was performed to prepare the quantitative method of judging the sensitive prognosis of chronic apical periodontitis as early as possible. The subjects were 25 cases with periapical radiolucencies of which were treated with endodontic treatment. Serial radiographs were taken by standardized method longitudinally. The density slice function of digital radiographic system were employed for quantitative and longitudinal assessment of the radiolucent area and the condensing osteitis simultaneously. Obtained results were as follows: 1. The amount of bone repair after endodontic treatment could be detected quantitatively by the density slice function of digital radiographic system. 2. Within the 6-week period after root canal filling, the prognosis could be evaluated by assessment both radiolucent area and condensing osteitis on digital radiographic system. 3. The pattern of bone repair showed peripheral type in most cases from the 6th week after root canal filling. 4. In longitudinal change, bone repair showed two patterns; the succeeding reduction of radiolucent area showing the increase of condensing osteitis in size till 6th week and following by static state or reduction tendency and the reduction following the initial increase of both areas. 5. Cases with pulpitis by trauma showed initial increase of condensing osteitis at 2nd week, marked reduction of radiolucent area and condensing osteitis at 6th week, and approximately normal bone state at 8th week after root canal filling.

  13. A quantitative study of bone repair after endodontic therapy on digital subtraction radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Duk [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Chosun University, Kwangju (Korea, Republic of)

    1997-08-15

    This study was performed to prepare the quantitative method of judging the sensitive prognosis of chronic apical periodontitis as early as possible. The subjects were 25 cases with periapical radiolucencies of which were treated with endodontic treatment. Serial radiographs were taken by standardized method longitudinally. The density slice function of digital radiographic system were employed for quantitative and longitudinal assessment of the radiolucent area and the condensing osteitis simultaneously. Obtained results were as follows: 1. The amount of bone repair after endodontic treatment could be detected quantitatively by the density slice function of digital radiographic system. 2. Within the 6-week period after root canal filling, the prognosis could be evaluated by assessment both radiolucent area and condensing osteitis on digital radiographic system. 3. The pattern of bone repair showed peripheral type in most cases from the 6th week after root canal filling. 4. In longitudinal change, bone repair showed two patterns; the succeeding reduction of radiolucent area showing the increase of condensing osteitis in size till 6th week and following by static state or reduction tendency and the reduction following the initial increase of both areas. 5. Cases with pulpitis by trauma showed initial increase of condensing osteitis at 2nd week, marked reduction of radiolucent area and condensing osteitis at 6th week, and approximately normal bone state at 8th week after root canal filling.

  14. Removing ECG Artifact from the Surface EMG Signal Using Adaptive Subtraction Technique

    Science.gov (United States)

    Abbaspour, S; Fallah, A

    2014-01-01

    Background: The electrocardiogram artifact is a major contamination in the electromyogram signals when electromyogram signal is recorded from upper trunk muscles and because of that the contaminated electromyogram is not useful. Objective: Removing electrocardiogram contamination from electromyogram signals. Methods: In this paper, the clean electromyogram signal, electrocardiogram artifact and electrocardiogram signal were recorded from leg muscles, the pectoralis major muscle of the left side and V4, respectively. After the pre-processing, contaminated electromyogram signal is simulated with a combination of clean electromyogram and electrocardiogram artifact. Then, contaminated electromyogram is cleaned using adaptive subtraction method. This method contains some steps; (1) QRS detection, (2) formation of electrocardiogram template by averaging the electrocardiogram complexes, (3) using low pass filter to remove undesirable artifacts, (4) subtraction. Results: Performance of our method is evaluated using qualitative criteria, power spectrum density and coherence and quantitative criteria signal to noise ratio, relative error and cross correlation. The result of signal to noise ratio, relative error and cross correlation is equal to 10.493, 0.04 and %97 respectively. Finally, there is a comparison between proposed method and some existing methods. Conclusion: The result indicates that adaptive subtraction method is somewhat effective to remove electrocardiogram artifact from contaminated electromyogram signal and has an acceptable result. PMID:25505766

  15. Digital Holographic Microscopy Principles, Techniques, and Applications

    CERN Document Server

    Kim, Myung K

    2011-01-01

    Digital holography is an emerging field of new paradigm in general imaging applications. By replacing the photochemical procedures with electronic imaging and having a direct numerical access to the complex optical field, a wide range of new imaging capabilities become available, many of them difficult or infeasible in conventional holography. An increasing number of researchers—not only in optical physics and optical engineering, but also in diverse applications areas such as microbiology, medicine, marine science, particle analysis, microelectromechanics, and metrology—are realizing and exploiting the new capabilities of digital holography. Digital Holographic Microscopy: Principles, Techniques, and Applications, by Dr. Myung K. Kim, is intended to provide a brief but consistent introduction to the principles of digital holography as well as to give an organized overview of the large number of techniques and applications being developed. This will also shed some light on the range of possibilities for f...

  16. Radiological investigation of renovascular hypertension from IVU to digital subtraction angiography. A critical evaluation

    International Nuclear Information System (INIS)

    Amiel, M.; Froment, A.; Pinet, F.; Huguet, M.

    1986-01-01

    For the last 20 years, the value of radiology in renovascular hypertension (RVH) is well established from diagnostic and therapeutic points of view. However things are changing now due to a better appraisal of the incidence of RVH, new antihypertensive drugs, and new radiological procedures (digital angiography, percutaneous transluminal angioplasty). The approach now takes in account the mode of imaging for a better evaluation of the renal artery stenosis and costs of the proceedings as well. Finally a new strategy has been set up for RVH patients management [fr

  17. Subtractive Leadership

    Science.gov (United States)

    Larwin, K. H.; Thomas, Eugene M.; Larwin, David A.

    2015-01-01

    This paper introduces a new term and concept to the leadership discourse: Subtractive Leadership. As an extension of the distributive leadership model, the notion of subtractive leadership refers to a leadership style that detracts from organizational culture and productivity. Subtractive leadership fails to embrace and balance the characteristics…

  18. Detection and characterization of intracranial aneurysms with 16-channel multidetector row CT angiography: a prospective comparison of volume-rendered images and digital subtraction angiography.

    Science.gov (United States)

    Yoon, D Y; Lim, K J; Choi, C S; Cho, B M; Oh, S M; Chang, S K

    2007-01-01

    The aim of our study was to compare multidetector row CT angiography (MDCTA) with digital subtraction angiography (DSA) in the detection and characterization of intracranial aneurysms. In our blinded prospective study, 85 patients with suspected intracranial aneurysm (47 women, 38 men; age range, 19-83 years) underwent both 16-channel MDCTA and DSA. The MDCT angiograms were interpreted for the presence, location, size, ratio of the neck to the dome (N/D ratio), and lobularity of the aneurysms and relationship of the aneurysm with the adjacent arterial branches, by using volume-rendering techniques. MDCTA and DSA images (reference standard) were interpreted by 2 independent readers, and the results were compared. A total of 93 aneurysms were detected at DSA in 71 patients, whereas no aneurysms were detected in 14 patients. Compared with DSA, the overall sensitivity, specificity, and accuracy of MDCTA on a per-aneurysm basis were 92.5%, 93.3%, and 92.6%, respectively, for both independent readers. For aneurysms of <3 mm, however, MDCTA had a sensitivity of 74.1% for reader 1 and 77.8% for reader 2. There was excellent agreement between readers in the detection of aneurysms (kappa = 0.822). In addition, MDCTA was also accurate in determining N/D ratio of aneurysms, aneurysm lobularity, and adjacent arterial branches. MDCTA is accurate in the detection and characterization of intracranial aneurysms and can be used as a reliable alternative imaging technique to DSA in selected cases.

  19. Suppression of high-density artefacts in x-ray CT images using temporal digital subtraction with application to cryotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Baissalov, R.; Sandison, G.A.; Rewcastle, J.C. [Department of Medical Physics, Tom Baker Cancer Center, Calgary, Canada, T2N 4N2 2 Department of Physics and Astronomy, University of Calgary, Calgary T2N 2N4 (Canada); Donnelly, B.J. [Department of Surgery, Tom Baker Cancer Center, Calgary, Canada, T2N 4N2 4 Department of Surgery, Foothills Hospital, Calgary T2N 2T7 (Canada); Saliken, J.C. [Department of Surgery, Tom Baker Cancer Center, Calgary T2N 4N2 (Canada); Department of Diagnostic Imaging, Foothills Hospital, Calgary T2N 2T7 (Canada); McKinnon, J.G. [Department of Surgery, Foothills Hospital, Calgary T2N 2T7 (Canada); Muldrew, K. [Department of Surgery, Faculty of Medicine, University of Calgary, Calgary T2N 2T7 (Canada)

    2000-05-01

    Image guidance in cryotherapy is usually performed using ultrasound. Although not currently in routine clinical use, x-ray CT imaging is an alternative means of guidance that can display the full 3D structure of the iceball, including frozen and unfrozen regions. However, the quality of x-ray CT images is compromised by the presence of high-density streak artefacts. To suppress these artefacts we applied temporal digital subtraction (TDS). This TDS method has the added advantage of improving the grey-scale contrast between frozen and unfrozen tissue in the CT images. Two sets of CT images were taken of a phantom material, cryoprobes and a urethral warmer (UW) before and during the cryoprobe freeze cycle. The high-density artefacts persisted in both image sets. TDS was performed on these two image sets using the corresponding mask image of unfrozen material and the same geometrical configuration of the cryoprobes and the UW. The resultant difference image had a significantly reduced artefact content. Thus TDS can be used to significantly suppress or eliminate high-density CT streak artefacts without reducing the metallic content of the cryoprobes. In vivo study needs to be conducted to establish the utility of this TDS procedure for CT assisted prostate or liver cryotherapy. Applying TDS in x-ray CT guided cryotherapy will facilitate estimation of the number and location of all frozen and unfrozen regions, potentially making cryotherapy safer and less operator dependent. (author)

  20. Suppression of high-density artefacts in x-ray CT images using temporal digital subtraction with application to cryotherapy

    International Nuclear Information System (INIS)

    Baissalov, R.; Sandison, G.A.; Rewcastle, J.C.; Donnelly, B.J.; Saliken, J.C.; McKinnon, J.G.; Muldrew, K.

    2000-01-01

    Image guidance in cryotherapy is usually performed using ultrasound. Although not currently in routine clinical use, x-ray CT imaging is an alternative means of guidance that can display the full 3D structure of the iceball, including frozen and unfrozen regions. However, the quality of x-ray CT images is compromised by the presence of high-density streak artefacts. To suppress these artefacts we applied temporal digital subtraction (TDS). This TDS method has the added advantage of improving the grey-scale contrast between frozen and unfrozen tissue in the CT images. Two sets of CT images were taken of a phantom material, cryoprobes and a urethral warmer (UW) before and during the cryoprobe freeze cycle. The high-density artefacts persisted in both image sets. TDS was performed on these two image sets using the corresponding mask image of unfrozen material and the same geometrical configuration of the cryoprobes and the UW. The resultant difference image had a significantly reduced artefact content. Thus TDS can be used to significantly suppress or eliminate high-density CT streak artefacts without reducing the metallic content of the cryoprobes. In vivo study needs to be conducted to establish the utility of this TDS procedure for CT assisted prostate or liver cryotherapy. Applying TDS in x-ray CT guided cryotherapy will facilitate estimation of the number and location of all frozen and unfrozen regions, potentially making cryotherapy safer and less operator dependent. (author)

  1. Variations and Anomalies of the circle of Willis in Korean: Cerebral digital subtraction angiogram studies in 200 case

    International Nuclear Information System (INIS)

    Lee, Ouk; Chung, Gyoo Sik; Kim, So Sun; Huh, Jin Do; Kim, Ho Joon; Joh, Young Duk

    1989-01-01

    In order to evaluate the variations of the circle of Willis in Korean population, digital subtraction angiograms in 200 cases were retrospectively analyzed. There was non-visualization of the anterior communicating artery and the posterior communicating artery in 41 cases and this was the most common type 4 vessel cerebral angiogram (20.5%). Unilateral or bilateral non-visualization of the posterior communicating artery was noted in 40 case (20%). The fetal origin of the posterior cerebral artery from the internal carotid artery was seen in 22 cases (11%). In 20 out of 22 cases, there were non-visualization of either the anterior communicating or posterior communicating artery. Visualization of the anterior communicating artery was noted in 102 cases (51%) and of the posterior communicating artery in 87 cases (43.5%). Hypoplasia of the anterior cerebral artery was noted in 24 cases (12%). Non- visualization of the anterior communicating artery or unilateral posterior communicating artery is noted in 16 cases (8%). Non- visualization of the anterior communicating artery was seen in 14 cases (7%). The most common type in appearance of the basilar artery variation was straight type (Type 1: 51%) and the bifurcation of the basilar artery was most commonly located above the posterior clinoid process of the dorsum sellae (58%) on vertebral angiogram

  2. A comparison between ultrasonography and mammography, computed tomography and digital subtraction angiography for the detection of breast cancers

    Energy Technology Data Exchange (ETDEWEB)

    Tohnosu, Noriyuki; Okuyama, Kazuaki; Koide, Yoshio (Chiba Univ. (Japan). School of Medicine) (and others)

    1993-08-01

    Ultrasound (US) was compared with mammography (MMG), computed tomography (CT), and digital subtraction angiography (DSA) in its effectiveness to detect breast cancer masses and metastatic axillary nodes. Forty-seven breast cancer patients who all underwent MMG, US, CT, and DSA preoperatively in our institution between 1986 and 1990 were studied. US was able to detect tumors in all cases regardless of tumor size, whereas DSA detected T1-size tumors and MMG detected T2-size tumors in 40% and 64.7% of cases, respectively, being specifically inferior to US. It was found that MMG was least likely to detect papillotubular carcinoma, although microcalcification alone without a tumor mass on MMG improved detectability from 46.2% to 76.9%, according to the histological type. CT was found to be most sensitive to axillary node metastases (81.8%), followed by US (72.7%), but DSA was significantly unfavorable (42.9%). Thus, we concluded that US was superior to MMG, CT, and DSA for detecting breast cancer masses, but that CT was more advantageous than US, while DSA was of little value for evaluating axillary nodal status. (author).

  3. Correlation Between Contrast Time-Density Time on Digital Subtraction Angiography and Flow: An in Vitro Study.

    Science.gov (United States)

    Brunozzi, Denise; Shakur, Sophia F; Ismail, Rahim; Linninger, Andreas; Hsu, Chih-Yang; Charbel, Fady T; Alaraj, Ali

    2018-02-01

    Digital subtraction angiography (DSA) provides an excellent anatomic characterization of cerebral vasculature, but hemodynamic assessment is often qualitative and subjective. Various clinical algorithms have been produced to semiquantify flow from the data obtained from DSA, but few have tested them against reliable flow values. An arched flow model was created and injected with contrast material. Seventeen injections were acquired in anterior-posterior and lateral DSA projections, and 4 injections were acquired in oblique projection. Image intensity change over the angiogram cycle of each DSA run was analyzed through a custom MATLAB code. Time-density plots obtained were divided into 3 components (time-density times, TDTs): TDT 10%-100% (time needed for contrast material to change image intensity from 10% to 100%), TDT 100%-10% (time needed for contrast material to change image intensity from 100% to 10%), and TDT 25%-25% (time needed for contrast material to change from 25% image intensity to 25%). Time-density index (TDI) was defined as model cross-sectional area to TDT ratio, and it was measured against different flow rates. TDI 10%-100% , TDI 100%-10% , and TDI 25%-25% all correlated significantly with flow (P flow. TDI on DSA correlates significantly with flow. Although in vitro studies might overlook conditions that occur in patients, this method appears to correlate with the flow and could offer a semiquantitative method to evaluate the cerebral blood flow. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Detection of unruptured familial intracranial aneurysms by intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Berg, H.W.M. ter; Regional Hospital Almelo; Overtoom, T.M.D.; Ludwig, J.W.; Bijlsma, J.B.; Tulleken, C.A.F.; Willemse, J.

    1987-01-01

    The authors discuss the detection of intracranial aneurysms (IA) by means of intravenous digital angiography (ivDSA) in (a)symptomatic first degree relatives of families in which more than two or more individuals have IA. ivDSA is an almost noninvasive and low-risk diagnostic procedure. Screening, by means of ivDSA, of two affected families is described. In family I which includes 7 members with proven IA, ivDSA has been carried out in 36 asymptomatic individuals: in one, a 6x15 mm aneurysm was found at the left posterior communicating artery (PCoA). In family II, including one member with a proven IA and another with a subarachnoidal hemorrhage, ivDSA has been carried out in 4 members: one aneurysm with a diameter of 6 mm was found at the left PCoA. Conventional cerebral angiography (CCA) confirmed both IA's. Neurosurgical treatment followed. The advantages and disadvantages of ivDSA vs. CCA as elective screening procedure in such cases are discussed. Screening of asymptomatic first degree relatives of cases with familial IA by means of ivDSA is strongly advocated. (orig.)

  5. On the technique of digital X-ray image processing, especially of digital substraction angiography

    International Nuclear Information System (INIS)

    Pfeiler, M.; Marhoff, P.

    1983-01-01

    Digital radiography, especially in the form of subtraction angiography, has found special consideration during the last two years as could be noted at many radiological conventions. Also a series of symposia was especially devoted to this subject. The extensive picture material shown at these conventions does not only document an important extension of the fields of application, but also an important increment in clinical and technical experience. Two pictures may represent many other examples: with a time lag of less than one year the improvement of objective and subjective image quality is easy to recognize. The principle and the technology of digital radiography were demonstrated at these conventions as well as in this magazine, and they also were discussed in detail; therefore a comprehensive review with only a few concepts necessary for defining the topic is sufficient here. Of the different imaging techniques, the fluorographic and the pulsed operation techniques are discussed, especially with regard to the storage method used. The definition of these concepts follows later. Special emphasis is put on some considerations of the signal-to-noise ratio that represents an essential criterion of the image quality. (orig.) [de

  6. Improved Reference Sampling and Subtraction: A Technique for Reducing the Read Noise of Near-infrared Detector Systems

    Science.gov (United States)

    Rauscher, Bernard J.; Arendt, Richard G.; Fixsen, D. J.; Greenhouse, Matthew A.; Lander, Matthew; Lindler, Don; Loose, Markus; Moseley, S. H.; Mott, D. Brent; Wen, Yiting; Wilson, Donna V.; Xenophontos, Christos

    2017-10-01

    Near-infrared array detectors, like the James Webb Space Telescope (JWST) NIRSpec’s Teledyne’s H2RGs, often provide reference pixels and a reference output. These are used to remove correlated noise. Improved reference sampling and subtraction (IRS2) is a statistical technique for using this reference information optimally in a least-squares sense. Compared with the traditional H2RG readout, IRS2 uses a different clocking pattern to interleave many more reference pixels into the data than is otherwise possible. Compared with standard reference correction techniques, IRS2 subtracts the reference pixels and reference output using a statistically optimized set of frequency-dependent weights. The benefits include somewhat lower noise variance and much less obvious correlated noise. NIRSpec’s IRS2 images are cosmetically clean, with less 1/f banding than in traditional data from the same system. This article describes the IRS2 clocking pattern and presents the equations needed to use IRS2 in systems other than NIRSpec. For NIRSpec, applying these equations is already an option in the calibration pipeline. As an aid to instrument builders, we provide our prototype IRS2 calibration software and sample JWST NIRSpec data. The same techniques are applicable to other detector systems, including those based on Teledyne’s H4RG arrays. The H4RG’s interleaved reference pixel readout mode is effectively one IRS2 pattern.

  7. Dynamic contrast-enhanced MRI coupled with a subtraction technique is useful for treatment response evaluation of malignant melanoma hepatic metastasis.

    Science.gov (United States)

    Lee, Minsu; Baek, Song-Ee; Moon, Jieun; Roh, Yun Ho; Lim, Joon Seok; Park, Mi-Suk; Kim, Myeong-Jin; Kim, Honsoul

    2016-06-21

    To determine whether contrast-enhanced MRI including subtraction sequences can predict the treatment response of melanoma liver metastasis. High precontrast T1 signal intensity (SI) of melanoma lesions obscured detection of enhancement after contrast injection. It was impossible to determine whether or not enhancement occurred in the majority of lesions (85.4%, n = 35/41) without including the subtraction technique. Positive enhancement was identified in 14.6% (n = 6/41) of patients without subtraction images, but increased to 68.3% (n = 28/41) by including subtraction images. Follow-up studies determined lesion progression in 34.1% (n = 14/41) of patients. Positive enhancement on the subtraction image (odds ratio = 12.1, P = 0.048) and intermediate high T2 SI (odds ratio = 8.16, P = 0.040) were significantly associated with higher risk of lesion progression. Patients who underwent MRI for melanoma liver metastases between January 2007 and February 2015 were enrolled. The study analyzed 41 liver metastases in 15 patients [11 male and four female; median age 56 years (range 21-81)] for size, lesion enhancement with and without subtraction images, and T2 SI. Follow-up imaging studies were used to determine treatment response. Data were analyzed with generalized estimating equations. MRI including the subtraction technique is useful for determining the treatment response of melanoma liver metastases. Lesion contrast enhancement and intermediate high T2 SI increased the risk of lesion progression.

  8. Comparison of high-resolution contrast-enhanced 3D MRA with digital subtraction angiography in the evaluation of hepatic arterial anatomy

    International Nuclear Information System (INIS)

    Matoba, M.; Tonami, H.; Kuginuki, M.; Yokota, H.; Takashima, S.; Yamamoto, I.

    2003-01-01

    AIM: To evaluate the validity of high-resolution contrast-enhanced three-dimensional magnetic resonance angiography (MRA) in defining hepatic arterial anatomy and to compare this with digital subtraction angiography (DSA). MATERIALS AND METHODS: MRA and DSA were performed in 30 patients. MRA was performed with breath-hold, gadolinium-enhanced, three-dimensional, fast low-angle shot sequence with a 512 pixel matrix. MRA was compared with DSA in terms of image quality and depiction of hepatic arterial anatomy. The agreement in image quality between MRA and DSA was determined with the kappa statistic. RESULTS: With respect to image quality, there was excellent or good correlation between MRA and DSA for the common hepatic artery (κ=0.85), proper hepatic artery (κ=0.72), gastroduodenal artery (κ=0.70), left hepatic artery (κ=0.49), left gastric artery (κ=0.50), splenic artery (κ=0.84), and superior mesenteric artery (κ=0.88). Poor correlation was found for the right hepatic artery (κ=0.18) and right gastric artery (κ=0.38). With regard to hepatic arterial anatomy, MRA correlated correctly with DSA in 28 of the 29 cases, i.e. 97% of patients. CONCLUSION: MRA is a useful technique for the evaluation of the hepatic artery, and for the vast majority of patients, MRA can replace intra-arterial DSA

  9. Conventional digital subtraction x-ray angiography versus magnetic resonance angiography in the evaluation of carotid disease: patient satisfaction and preferences

    Energy Technology Data Exchange (ETDEWEB)

    U-King-Im, J.M. E-mail: jhg21@cam.ac.uk; Trivedi, R.; Cross, J.; Higgins, N.; Graves, M.; Kirkpatrick, P.; Antoun, N.; Gillard, J.H

    2004-04-01

    AIM: To compare conventional digital subtraction x-ray angiography (DSA) and contrast-enhanced magnetic resonance angiography (MRA) of the carotid arteries in terms of patient satisfaction and preferences. METHODS: One hundred and sixty-seven patients with symptomatic carotid artery disease, who underwent both DSA and MRA, were prospectively recruited in this study. Patients' perceptions of each method were assessed by the use of a questionnaire after each procedure. Main outcome measures were anxiety, pain, satisfaction rate and patient preferences. RESULTS: DSA generated more anxiety and pain during the procedure, but the severity of these ill-effects was mild. Satisfaction rates for each method were similar. More patients were, however, willing to have a repeat MRA compared with DSA (67 versus 41%). The majority of patients (62%) preferred MRA over DSA (31%). The shorter MRA imaging time was found to be a significant factor in patients' acceptance of the technique. The main reasons cited by patients for their dislike of a particular procedure was noise and claustrophobia for MRA and invasiveness, pain and post-procedural bed rest for DSA. CONCLUSIONS: MRA is the method that is preferred by the majority of patients, although the actual disutility of DSA may be small. Assuming equal diagnostic accuracy, our data supports replacement of DSA by MRA for routine carotid imaging.

  10. The value of digital subtraction angiography in diagnosing small intestinal hemorrhage with unknown reasons

    International Nuclear Information System (INIS)

    Luo Guanghua; Xiao Wenlian; Tang Deqiu; Chan Hong

    2006-01-01

    Objective: To discuss the diagnostic value of DSA for unknown reason hemorrhage of small intestine. Methods: 25 patients with hemorrhage of small intestine were performed angiography with Seldinger's technique through superior mesenteric artery. Results: Eleven cases demonstrated direct signs of hemorrhage, 12 cases of indirect signs of hemorrhage and 5 with both of the signs. The positive rate of hemorrhage was 72% including 10 cases of tumor (6 leiomyomas, 2 leiomyosarcomas, 1 interstitial tumor, 1 small intestinal cancer), 4 cases of Meckel's diverticulum, 3 cases of vascular malformation and 1 case of inflammation. The coincidence rate of positive cases with pathology was 75% and the diagnostic accuracy of localization was 100%. Conclusions: DSA angiography is very helpful for determining the location and character of unknown reason hemorrhage of small intestine. (authors)

  11. Conventional renal angiography versus renal digital subtraction angiography (DSA) in the study of renovascular hypertension

    International Nuclear Information System (INIS)

    Essinger, A.; Morsier, B. de; Narbel, M.; Raimondi, S.

    1988-01-01

    A cost-benefit analysis comparing conventional renal angiography, IV and IA DSA and spot film cameras has been made in order to quantify the advantages and disadvantages of these techniques in screening for renal artery stenosis. DSA is the best modality of imaging, using very little films, easy to archive, with a spatial resolution inferior to conventional angiography but partially compensated by contrast resolution. The surface dose per image using a 512/512 matrix is two thirds less than a conventional film, giving thus an acceptable dose as long as technical personnel is well trained and thus the number of exposures is kept low. Spot film camera, due to its excellent spatial resolution, its low radiation dose and its low price, can also be used as a screening procedure but requires an arterial injection. DSA has furthermore the advantage of quantifying renal artery stenosis making future percutaneous transluminal angioplasty easier

  12. An automatic fuzzy-based multi-temporal brain digital subtraction angiography image fusion algorithm using curvelet transform and content selection strategy.

    Science.gov (United States)

    Momeni, Saba; Pourghassem, Hossein

    2014-08-01

    Recently image fusion has prominent role in medical image processing and is useful to diagnose and treat many diseases. Digital subtraction angiography is one of the most applicable imaging to diagnose brain vascular diseases and radiosurgery of brain. This paper proposes an automatic fuzzy-based multi-temporal fusion algorithm for 2-D digital subtraction angiography images. In this algorithm, for blood vessel map extraction, the valuable frames of brain angiography video are automatically determined to form the digital subtraction angiography images based on a novel definition of vessel dispersion generated by injected contrast material. Our proposed fusion scheme contains different fusion methods for high and low frequency contents based on the coefficient characteristic of wrapping second generation of curvelet transform and a novel content selection strategy. Our proposed content selection strategy is defined based on sample correlation of the curvelet transform coefficients. In our proposed fuzzy-based fusion scheme, the selection of curvelet coefficients are optimized by applying weighted averaging and maximum selection rules for the high frequency coefficients. For low frequency coefficients, the maximum selection rule based on local energy criterion is applied to better visual perception. Our proposed fusion algorithm is evaluated on a perfect brain angiography image dataset consisting of one hundred 2-D internal carotid rotational angiography videos. The obtained results demonstrate the effectiveness and efficiency of our proposed fusion algorithm in comparison with common and basic fusion algorithms.

  13. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique

    OpenAIRE

    Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan; Kim, Hae-Young

    2014-01-01

    Objective This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Methods Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP techn...

  14. Research on digital multi-channel pulse height analysis techniques

    International Nuclear Information System (INIS)

    Xiao Wuyun; Wei Yixiang; Ai Xianyun; Ao Qi

    2005-01-01

    Multi-channel pulse height analysis techniques are developing in the direction of digitalization. Based on digital signal processing techniques, digital multi-channel analyzers are characterized by powerful pulse processing ability, high throughput, improved stability and flexibility. This paper analyzes key techniques of digital nuclear pulse processing. With MATLAB software, main algorithms are simulated, such as trapezoidal shaping, digital baseline estimation, digital pole-zero/zero-pole compensation, poles and zeros identification. The preliminary general scheme of digital MCA is discussed, as well as some other important techniques about its engineering design. All these lay the foundation of developing homemade digital nuclear spectrometers. (authors)

  15. Application of MR digital subtraction angiography to the diagnosis of cerebral arteriovenous malformations

    International Nuclear Information System (INIS)

    Katase, Shichiro; Tsuchiya, Kazuhiro; Osawa, Ayako; Hachiya, Junichi

    2000-01-01

    We evaluated the utility of MR DSA using rapid thick-section T1-weighted imaging and bolus injections of gadolinium to diagnose cerebral arteriovenous malformations (AVMs). We reviewed MR DSA images obtained from 16 patients (9 men and 7 women; average age, 35.8 years). Anatomic depictions of each component of the AVMs were rated using a four-point grade scale and compared with conventional and/or MR angiograms. We were able to obtain serial images demonstrating passage of gadolinium through the AVM. The average scores for feeders, nidus, and drainers was 1.4, 2.2, and 1.8, respectively with the overall average of 2.1. The MR DSA technique that we have developed presently has limited value in depicting the anatomic details of cerebral AVMs. However, we believe that MR DSA is valuable and should be used in addition to conventional MR imaging and angiography in patients with cerebral AVM at the time of their initial diagnosis and during follow-up after therapy. (author)

  16. Contrast enhancing techniques in digital holographic microscopy

    International Nuclear Information System (INIS)

    Lobera, J; Coupland, J M

    2008-01-01

    A digital holographic microscope (DHM) can be considered as a microscope with an extended depth of field. From a single DHM recording the propagating component of the scattered field can be reconstructed in three dimensions (3D). As in conventional white light microscopy contrasting enhancing techniques can be applied to highlight characteristics of interest. If these techniques are used to enhance the reconstruction from a DHM, then it is important to understand the characteristics of these techniques in 3D. In this paper the performance of phase contrast, differential interference contrast, Hoffman and spiral phase contrast visualization methods are discussed in 3D

  17. Extrahepatic Arteries Originating from Hepatic Arteries: Analysis Using CT During Hepatic Arteriography and Visualization on Digital Subtraction Angiography

    Energy Technology Data Exchange (ETDEWEB)

    Ozaki, Kumi, E-mail: ozakik-rad@umin.org [Kanazawa University Graduate School of Medical Science, Department of Radiology (Japan); Kobayashi, Satoshi [Kanazawa University Graduate School of Medical Science, Department of Quantum Medicine Technology (Japan); Matsui, Osamu; Minami, Tetsuya; Koda, Wataru; Gabata, Toshifumi [Kanazawa University Graduate School of Medical Science, Department of Radiology (Japan)

    2017-06-15

    PurposeTo investigate the prevalence and site of origin of extrahepatic arteries originating from hepatic arteries on early phase CT during hepatic arteriography (CTHA) was accessed. Visualization of these elements on digital subtraction hepatic angiography (DSHA) was assessed using CTHA images as a gold standard.Materials and MethodsA total of 943 patients (mean age 66.9 ± 10.3 years; male/female, 619/324) underwent CTHA and DSHA. The prevalence and site of origin of extrahepatic arteries were accessed using CTHA and visualized using DSHA.ResultsIn 924 (98.0%) patients, a total of 1555 extrahepatic branches, representing eight types, were found to originate from hepatic arteries on CTHA. CTHA indicated the following extrahepatic branch prevalence rates: right gastric artery, 890 (94.4%); falciform artery, 386 (40.9%); accessory left gastric artery, 161 (17.1%); left inferior phrenic artery (IPA), 43 (4.6%); posterior superior pancreaticoduodenal artery, 33 (3.5%); dorsal pancreatic artery, 26 (2.8%); duodenal artery, 12 (1.3%); and right IPA, 4 (0.4%). In addition, 383 patients (40.6%) had at least one undetectable branch on DSHA. The sensitivity, specificity, and accuracy of visualization on DSHA were as follows: RGA, 80.0, 86.8, and 80.4%; falciform artery, 53.9, 97.7, and 80.0%; accessory LGA, 64.6, 98.6, and 92.3%; left IPA, 76.7, 99.8, and 98.7%; PSPDA, 100, 99.7, and 99.9%; dorsal pancreatic artery, 57.7, 100, and 98.8%; duodenal artery, 8.3, 99.9, and 98.7%; and right IPA, 0, 100, and 99.6%, respectively.ConclusionExtrahepatic arteries originating from hepatic arteries were frequently identified on CTHA images. These arteries were frequently overlooked on DSHA.

  18. CT Angiography of Peripheral Arterial Disease by 256-Slice Scanner: Accuracy, Advantages and Disadvantages Compared to Digital Subtraction Angiography.

    Science.gov (United States)

    Mishra, Atul; Jain, Narendra; Bhagwat, Anand

    2017-07-01

    Peripheral arterial occlusive disease (PAOD) may cause disabling claudication or critical limb ischemia. Multidetector computed tomography (CT) technology has evolved to the level of 256-slice CT scanners which has significantly improved the spatial and temporal resolution of the images. This has provided the capability of chasing the contrast bolus at a fast speed enabling angiographic imaging of long segments of the body. These images can be reconstructed in various planes and various modes for detailed analysis of the peripheral vascular diseases which helps in making treatment decision. The aim of this retrospective study was to compare the CT angiograms (CTAs) of all cases of PAOD done by 256-slice CT scanner at a tertiary care vascular center and comparing these images with the digital subtraction angiograms (DSAs) of these patients. The retrospective study included 53 patients who underwent both CTA and DSA at our center over a period of 3 years from March 2013 to March 2016. The CTA showed high sensitivity (93%) and specificity (92.7%) for overall assessment of degree of stenosis in a vascular segment in cases of aortic and lower limb occlusive disease. The assessment of lesions of infrapopliteal segment was comparatively inferior (sensitivity 91.6%, accuracy 73.3%, and positive predictive value 78.5%), more so in the presence of significant calcification. The advantages of CTA were its noninvasive nature, ability to image large area of body, almost no adverse effects to the patients, and better assessment of vessel wall disease. However, the CTA assessment of collaterals was inferior with a sensitivity of only 62.7% as compared to DSA. Overall, 256-slice CTA provides fast and accurate imaging of vascular tree which can restrict DSA only in few selected cases as a problem-solving tool where clinico-radiological mismatch is present.

  19. Utility of digital subtraction angiography-based collateral evaluation in medically treated acute symptomatic basilar artery stenosis.

    Science.gov (United States)

    Lee, W-J; Jung, K-H; Ryu, Y J; Kim, J-M; Lee, S-T; Chu, K; Kim, M; Lee, S K; Roh, J-K

    2017-09-01

    Although a stroke from atherosclerosis in the basilar artery (BA) often presents with mild initial stroke severity, it has heterogeneous clinical courses. We investigated the efficacy of digital subtraction angiography (DSA)-based collateral perfusion evaluation in association with long-term outcomes of medically treated symptomatic basilar artery stenosis. From a registry database of all consecutive patients with stroke, we included 98 medically treated patients (due to mild initial stroke severity) [National Institute of Health Stroke Scale (NIHSS) scores ≤ 4; symptomatic basilar artery stenosis, 70-99%] with available initial diagnostic DSA. Basilar collateral scoring was performed via the DSA, using a modified version of the American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology grading system in both the superior cerebellar artery and anterior/posterior-inferior cerebellar artery territories (score 0-8). The outcomes were designated as the 90-day modified Rankin Scale (mRS90) score (poor, 3-6). Student's t-test, chi-square test and logistic regression analyses were used to identify factors associated with a poor outcome. The median initial NIHSS score was 2 [interquartile range (IQR), 0-3], median posterior circulation Alberta Stroke Program Early CT Score was 8 (IQR, 7-10), median collateral score was 7 (IQR, 7-8) and 20 (20.4%) had poor mRS90 scores. In multivariate analysis, poorer collateral scores (P = 0.003), higher NIHSS scores (P = 0.005) and lower posterior circulation Alberta Stroke Program Early CT Score (P = 0.017) were independently associated with a poor mRS90 score. The DSA-based collateral scoring of the BA large branches might predict long-term outcome in medically treated symptomatic basilar artery stenosis with mild initial severity. Evaluation of BA collateral perfusion status might be useful to determine appropriate treatment strategies. © 2017 EAN.

  20. Detection of unruptured intracranial aneurysms on noninvasive imaging. Is there still a role for digital subtraction angiography?

    Science.gov (United States)

    Rustemi, Oriela; Alaraj, Ali; Shakur, Sophia F; Orning, Jennifer L; Du, Xinjian; Aletich, Victor A; Amin-Hanjani, Sepideh; Charbel, Fady T

    2015-01-01

    To determine the utility of digital subtraction angiography (DSA) in patients with unruptured intracranial aneurysms (UIA) detected on noninvasive imaging, such as magnetic resonance angiography (MRA) and computed tomography angiography (CTA). The follow-up of patients with untreated UIAs involves serial imaging; however, this diagnosis may be based on false positive (FP) results. We examined the incidence of FPs in our institutional series. DSAs performed at our institution from January 2011 to June 2014 were retrospectively reviewed and patients referred with UIA detected on noninvasive imaging were selected. Clinical presentation as well as aneurysm location, size, and number reported on DSA and noninvasive imaging were assessed. Two hundred and eighty six patients (mean age 56.8 years, female 74.8%) with a total of 355 UIA were included. Thirty-one patients had a symptomatic presentation. Analysis per patient showed the pooled FP rate of noninvasive imaging was 15%. MRA FP was 13% (22/171) and CTA FP was 18% (22/120). FP increased significantly with aneurysm size < 3.5 mm on MRA (P < 0.001) and <4.0 mm on CTA (P = 0.01). Mean aneurysm size among symptomatic patients was significantly larger (P < 0.001) as compared to the incidental group (17.8 vs. 7.7 mm). No location was significantly susceptible to false detection of aneurysms. DSA detection of FP UIA diagnosed on noninvasive imaging is significantly higher for aneurysms <4.0 mm. Accurate diagnosis with DSA may eliminate the need for further follow-up and its associated negative psychological and economic effects. Within the limitations of this retrospective study, we conclude that DSA has a diagnostic role in small aneurysms detected on noninvasive imaging.

  1. Three-dimensional CT-angiography after cerebral aneurysm clipping. Comparison with intra-arterial digital subtraction angiography

    International Nuclear Information System (INIS)

    Sakuma, Ikuo; Tomura, Noriaki; Takahashi, Satoshi; Omachi, Koichi; Otani, Takahiro; Watarai, Jiro; Kinouchi, Hiroyuki; Mizoi, Kazuo

    2004-01-01

    To assess the significance of three-dimensional CT-angiography (3D-CTA) in detecting remnant necks after cerebral aneurysm clipping, 3D-CTA was compared with intra-arterial digital subtraction angiography (IADSA). Fifty-nine patients (79 aneurysms) underwent both IADSA and 3D-CTA after cerebral aneurysm clipping. A single detector spiral scanner was used for 3D-CTA. Shaded surface display (SSD) and volume rendered (VR) images were produced from each data set. Two blinded observers independently evaluated the presence of remnant necks on SSD images, VR images and IADSA. Results jointly evaluated by three observers were applied as the gold standard to assess diagnostic accuracy of each image. Diagnostic performance of each image was evaluated using receiver operating characteristic (ROC) analysis. Mean sensitivity and specificity of SSD images for detecting remnant necks were 50.0% and 74.2%, respectively. VR images displayed a mean sensitivity and specificity of 63.3% and 82.8%, respectively. IADSA demonstrated a mean sensitivity and specificity of 93.3% and 92.2%, respectively. Under ROC analysis, IADSA displayed excellent diagnostic performance (mean Az [area under ROC curve]=0.97). While 3D-CTA demonstrated good diagnostic performance (0.68 and 0.76 for SSD and VR, respectively), it was significantly inferior to IADSA (P<.001). Mean Az for VR imaging was significantly superior to that for SSD imaging (P<.001). Following clipping surgery for cerebral aneurysms, 3D-CTA, and particularly VR imaging, is useful for postoperative evaluation. As a noninvasive alternative, 3D-CTA could be recommended for routine use. However, IADSA should still be performed when 3D-CTA yields uncertain results. (author)

  2. Digital Mayhem 3D machine techniques where inspiration, techniques and digital art meet

    CERN Document Server

    Evans, Duncan

    2014-01-01

    From Icy Tundras to Desert savannahs, master the art of landscape and environment design for 2D and 3D digital content. Make it rain, shower your digital scene with a snow storm or develop a believable urban scene with a critical eye for modeling, lighting and composition. Move beyond the limitations of gallery style coffee table books with Digital Mayhem: 3D Landscapes-offering leading professional techniques, groundbreaking inspiration, and artistic mastery from some of the greatest digital artists. More than just a gallery book - each artist has written a breakdown overview, with supporting

  3. Cognitive behaviour modification: a technique for teaching subtraction skills to hearing and deaf/hard-of-hearing elementary students.

    Science.gov (United States)

    Al-Hilawani, Y A

    2000-09-01

    The purpose of this study was to examine the influence of using the Cognitive Behaviour Modification (CBM) technique on the subtraction skills of third grade hearing and deaf/hard-of-hearing students. The results indicated that the CBM deaf/hard-of-hearing students and the CBM and non-CBM hearing students made more progress in solving the subtraction problems than the non-CBM deaf/hard-of-hearing students. The results also showed that there were no significant differences between the CBM deaf/hard-of-hearing and the non-CBM hearing students; and there were no significant differences between the CBM and non-CBM hearing students. The results revealed that the CBM hearing students achieved significantly higher post-test scores than the CBM deaf/hard-of-hearing students. However, the CBM deaf/hard-of-hearing students obtained a significantly higher gain score compared to the CBM and non-CBM hearing students. Implications for teachers and suggestions for future research are discussed in this paper.

  4. Time-of-flight MR angiography at 3 T versus digital subtraction angiography in the imaging follow-up of 51 intracranial aneurysms treated with coils

    Energy Technology Data Exchange (ETDEWEB)

    Ferre, Jean-Christophe [Department of Neuroradiology, Hopital Pontchaillou, University Hospital Rennes, 2 rue Henri Le Guilloux, 35000 Rennes (France)], E-mail: jean-christophe.ferre@chu-rennes.fr; Carsin-Nicol, Beatrice [Department of Neuroradiology, Hopital Pontchaillou, University Hospital Rennes, 2 rue Henri Le Guilloux, 35000 Rennes (France); Morandi, Xavier [Department of Neurosurgery, Hopital Pontchaillou, University Hospital Rennes, 2 rue Henri Le Guilloux, 35000 Rennes (France); Carsin, Michel [Department of Neuroradiology, Hopital Pontchaillou, University Hospital Rennes, 2 rue Henri Le Guilloux, 35000 Rennes (France); Kersaint-Gilly, Axel de [Department of Neuroradiology, Hopital Laennec, University Hospital Nantes, Boulevard Jacques Monod, 44800 Saint-Herblain (France); Gauvrit, Jean-Yves [Department of Neuroradiology, Hopital Pontchaillou, University Hospital Rennes, 2 rue Henri Le Guilloux, 35000 Rennes (France); Desal, Hubert-Armand [Department of Neuroradiology, Hopital Laennec, University Hospital Nantes, Boulevard Jacques Monod, 44800 Saint-Herblain (France)

    2009-12-15

    Objective: To compare 3D time-of-flight MR angiography (TOF-MRA) at 3 Tesla (3 T) with digital subtraction angiography (DSA) for the evaluation of intracranial aneurysm occlusion after endovascular coiling. Methods: In a prospective study, 51 consecutive patients (25 females, 26 males; median age, 51 years) with 51 saccular aneurysms treated with endovascular coiling underwent simultaneous DSA and 3 T TOF-MRA at follow-up. DSA and TOF-MRA images were analyzed independently by two senior neuroradiologists. Findings were assigned to 1 of 3 categories in the Raymond classification: complete obliteration, residual neck or residual aneurysm. Agreement between observers and techniques was evaluated using {kappa} statistics. Results: DSA images were not interpretable for one patient. Interobserver agreement was determined as excellent for DSA ({kappa} = 0.86) and TOF-MRA ({kappa} = 0.80). After reaching a consensus, DSA follow-up showed 26 (51%) complete obliterations, 20 (39%) residual necks and 4 (8%) residual aneurysms. TOF-MRA showed 23 (45%) complete obliterations, 22 (43%) residual necks and 6 (12%) residual aneurysms. Comparison between TOF-MRA and DSA showed excellent agreement between the techniques ({kappa} = 0.86). In the four cases that were misclassified, TOF-MRA findings were assigned to a higher class than for DSA. Conclusion: TOF-MRA at 3 T is at least as efficient as DSA for the evaluation of intracranial aneurysm occlusion after endovascular treatment with detachable coils. We suggest that TOF-MRA at 3 T might be used as the primary method for imaging follow-up of coiled intracranial aneurysms.

  5. A comparison of subtracted images from dental subtraction programs

    International Nuclear Information System (INIS)

    Han, Won Jeong

    2002-01-01

    To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p<0.01). Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  6. A comparison of subtracted images from dental subtraction programs

    Energy Technology Data Exchange (ETDEWEB)

    Han, Won Jeong [School of Dentistry, Dankook University, Cheonan (Korea, Republic of)

    2002-09-15

    To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p<0.01). Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  7. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    International Nuclear Information System (INIS)

    Altaha, Mustafa A.; Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J.; Rick, Manuela; Schmitt, Peter; Wintersperger, Bernd J.

    2017-01-01

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm 2 ) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm 3 ) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  8. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Altaha, Mustafa A. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Rick, Manuela; Schmitt, Peter [Siemens Healthcare, Erlangen (Germany); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-03-15

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm{sup 2}) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm{sup 3}) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  9. Comparison of C-arm Computed Tomography and Digital Subtraction Angiography in Patients with Chronic Thromboembolic Pulmonary Hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Hinrichs, Jan B., E-mail: hinrichs.jan@mh-hannover.de; Marquardt, Steffen, E-mail: marquardt.steffen@mh-hannover.de; Falck, Christian von, E-mail: falck.christian.von@mh-hannover.de [Hannover Medical School, Department for Diagnostic and Interventional Radiology, German Center for Lung Research (DZL) (Germany); Hoeper, Marius M., E-mail: hoeper.marius@mh-hannover.de; Olsson, Karen M., E-mail: olsson.karen@mh-hannover.de [Hannover Medical School, Clinic for Pneumology, German Center for Lung Research (DZL) (Germany); Wacker, Frank K., E-mail: wacker.frank@mh-hannover.de; Meyer, Bernhard C., E-mail: meyer.bernhard@mh-hannover.de [Hannover Medical School, Department for Diagnostic and Interventional Radiology, German Center for Lung Research (DZL) (Germany)

    2016-01-15

    PurposeTo assess the feasibility and diagnostic performance of contrast-enhanced, C-arm computed tomography (CACT) of the pulmonary arteries compared to digital subtraction angiography (DSA) in patients suffering from chronic thromboembolic pulmonary hypertension (CTEPH).MaterialsFifty-two patients with CTEPH underwent ECG-gated DSA and contrast-enhanced CACT. Two readers (R1, R2) independently evaluated pulmonary artery segments and their sub-segmental branching using DSA and CACT for optimal image quality. Afterwards, the diagnostic findings, i.e., intraluminal filling defects, stenosis, and occlusion, were compared. Inter-modality and inter-observer agreement was calculated, and subsequently consensus reading was done and correlated to a reference standard representing the overall consensus of both modalities. Fisher’s exact test and Cohen’s Kappa were applied.ResultsA total of 1352 pulmonary segments were evaluated, of which 1255 (92.8 %) on DSA and 1256 (92.9 %) on CACT were rated to be fully diagnostic. The main causes of the non-diagnostic image quality were motion artifacts on CACT (R1:37, R2:78) and insufficient contrast enhancement on DSA (R1:59, R2:38). Inter-observer agreement was good for DSA (κ = 0.74) and CACT (κ = 0.75), while inter-modality agreement was moderate (R1: κ = 0.46, R2: κ = 0.47). Compared to the reference standard, the inter-modality agreement for CACT was excellent (κ = 0.96), whereas it was inferior for DSA (κ = 0.61) due to the higher number of abnormal consensus findings read as normal on DSA.ConclusionCACT of the pulmonary arteries is feasible and provides additional information to DSA. CACT has the potential to improve the diagnostic work-up of patients with CTEPH and may be particularly useful prior to surgical or interventional treatment.

  10. Impact of femoral artery puncture using digital subtraction angiography and road mapping on vascular and bleeding complications after transfemoral transcatheter aortic valve implantation.

    Science.gov (United States)

    El-Mawardy, Mohamed; Schwarz, Bettina; Landt, Martin; Sulimov, Dmitriy; Kebernik, Julia; Allali, Abdelhakim; Becker, Bjoern; Toelg, Ralph; Richardt, Gert; Abdel-Wahab, Mohamed

    2017-01-20

    The use of large-diameter sheaths carries the risk of significant vascular and bleeding complications after transfemoral transcatheter aortic valve implantation (TAVI). In this analysis, we sought to assess the impact of a modified femoral artery puncture technique using digital subtraction angiography (DSA) and road mapping during transfemoral TAVI on periprocedural vascular and bleeding events. This is a retrospective analysis of transfemoral TAVI patients included in a prospective institutional database. The modified femoral artery puncture technique using DSA-derived road mapping guidance was introduced in October 2012. Before the introduction of this technique, vascular puncture was acquired based on an integration of angiographic data, the bony iliofemoral landmarks and a radiopaque object. Consecutive patients who underwent TAVI with the road mapping technique (RM group, n=160) were compared with consecutive patients who underwent TAVI without road mapping (control group, n=160) prior to its introduction. A standardised strategy of periprocedural anticoagulation was adopted in both groups as well as the use of a single suture-based closure device. All endpoints were defined according to the VARC-2 criteria for event definition. The mean age in the RM group was 80±7.7 years compared to 81±5.9 years in the control group (p=0.19), and females were equally distributed between both groups (63.1% vs. 58.1%, p=0.36). The baseline logistic EuroSCORE was 20.7±14.4% vs. 24.9±15.2% in the RM and control group, respectively (p=0.01). Notably, sheath size was significantly larger in the RM compared to the control group due to the more frequent use of the 20 Fr sheath (23.8% vs. 1.8%, proad map group but did not reach statistical significance (8.1% vs. 13.8%, p=0.1). Other forms of vascular and bleeding complications as well as all-cause mortality were comparable in both groups. A modified femoral artery puncture technique using DSA and road mapping was associated

  11. Optical and digital techniques for information security

    CERN Document Server

    2005-01-01

    Optical and Digital Techniques for Information Security is the first book in a series focusing on Advanced Sciences and Technologies for Security Applications. This book encompases the results of research investigation and technologies used to secure, verify, recognize, track, and authenticate objects and information from theft, counterfeiting, and manipulation by unauthorized persons and agencies. This Information Security book will draw on the diverse expertise in optical sciences and engineering, digital image processing, imaging systems, information processing, computer based information systems, sensors, detectors, and biometrics to report innovative technologies that can be applied to information security issues. The Advanced Sciences and Technologies for Security Applications series focuses on research monographs in the areas of: -Recognition and identification (including optical imaging, biometrics, authentication, verification, and smart surveillance systems) -Biological and chemical threat detection...

  12. Value of Single-Dose Contrast-Enhanced Magnetic Resonance Angiography Versus Intraarterial Digital Subtraction Angiography in Therapy Indications in Abdominal and Iliac Arteries

    International Nuclear Information System (INIS)

    Schaefer, Philipp J.; Schaefer, Fritz K. W.; Mueller-Huelsbeck, Stefan; Both, Markus; Heller, Martin; Jahnke, Thomas

    2007-01-01

    The objective of the study was to prove the value of single-dose contrast-enhanced magnetic resonance angiography [three-dimensional (3D) ceMRA] in abdominal and iliac arteries versus the reference standard intra-arterial digital subtraction angiography (i.a.DSA) when indicating a therapy. Patients suspected of having abdominal or iliac artery stenosis were included in this study. A positive vote of the local Ethics Committee was given. After written informed consent was obtained, 37 patients were enrolled, of which 34 were available for image evaluation. Both 3D ceMRA and i.a. DSA were performed for each patient. The dosage for 3D ceMRA was 0.1 mmol/kg body weight in a 1.5-T scanner with a phased-array coil. The parameters of the 3D-FLASH sequence were as follows: TR/TE 4.6/1.8 ms, effective thickness 3.5 mm, matrix 512 x 200, flip angle 30 o , field of view 420 mm, TA 23 s, coronal scan orientation. Totally, 476 vessel segments were evaluated for stenosis degree by two radiologists in a consensus fashion in a blinded read. For each patient, a therapy was proposed, if clinically indicated. Sensitivity, specificity, positive and negative predictive values, and accuracy for stenoses ≥50% were 68%, 92%, 44%, 97%, and 90%, respectively. In 13/34 patients, a discrepancy was found concerning therapy decisions based on MRA findings versus therapy decisions based on the reference standard DSA. The results showed that the used MRA imaging technique of abdominal and iliac arteries is not competitive to i.a. DSA, with a high rate of misinterpretation of the MRAs resulting in incorrect therapies

  13. The development of digital monitoring technique

    International Nuclear Information System (INIS)

    Koo, In Soo; Kim, D. H.; Kim, J. S.; Kim, C. H.; Kim, G. O.; Park, H. Y.; Suh, S. Y.; Sung, S. H.; Song, S. J.; Lee, C. K.; Jang, G. S.; Hur, S.

    1997-08-01

    A study has been performed for advanced DSP technology for the digital nuclear I and C systems for the monitoring and diagnosis techniques for high-pressurized structures integrity in NSSS. In the development of advanced DSP technology, real time process, communication network and signal validation were selected as the essential technologies of the digital signal process, and the requirements and methodology for the application of these technologies in NPP were established through technical analysis. Based on its results, the DPIS and the signal validation algorithm were developed. For the real-time process, the necessary requirements were define and the methodology of real-time software modeling was developed. For the communication network, the methodology of selection of the communication technique and developing procedure were established with an extraction of requirements. Functions, requirements, structure and technical specification were developed for the DPIS, and a real-time signal validation algorithm was developed and implemented for the signal validation. In a study on monitoring techniques for abnormal conditions, test and experimental facilities have been set up in order to carry out the required tests during research activities. Studies concentrated on how to acquire proper vibration or emission signals from mechanical structures and equipments, and to diagnose effectively the abnormal conditions of high pressure structure integrity. The algorithms of automatic signal analysis and diagnosis for abnormal conditions have been developed in this study to assist the operator's monitoring and diagnosis activities on structure integrity using new technologies. (author). 23 refs., 68 tabs., 196 figs

  14. The development of digital monitoring technique

    Energy Technology Data Exchange (ETDEWEB)

    Koo, In Soo; Kim, D. H.; Kim, J. S.; Kim, C. H.; Kim, G. O.; Park, H. Y.; Suh, S. Y.; Sung, S. H.; Song, S. J.; Lee, C. K.; Jang, G. S.; Hur, S.

    1997-08-01

    A study has been performed for advanced DSP technology for the digital nuclear I and C systems for the monitoring and diagnosis techniques for high-pressurized structures integrity in NSSS. In the development of advanced DSP technology, real time process, communication network and signal validation were selected as the essential technologies of the digital signal process, and the requirements and methodology for the application of these technologies in NPP were established through technical analysis. Based on its results, the DPIS and the signal validation algorithm were developed. For the real-time process, the necessary requirements were define and the methodology of real-time software modeling was developed. For the communication network, the methodology of selection of the communication technique and developing procedure were established with an extraction of requirements. Functions, requirements, structure and technical specification were developed for the DPIS, and a real-time signal validation algorithm was developed and implemented for the signal validation. In a study on monitoring techniques for abnormal conditions, test and experimental facilities have been set up in order to carry out the required tests during research activities. Studies concentrated on how to acquire proper vibration or emission signals from mechanical structures and equipments, and to diagnose effectively the abnormal conditions of high pressure structure integrity. The algorithms of automatic signal analysis and diagnosis for abnormal conditions have been developed in this study to assist the operator`s monitoring and diagnosis activities on structure integrity using new technologies. (author). 23 refs., 68 tabs., 196 figs.

  15. Subtract it! fun with subtraction

    CERN Document Server

    First, Rachel

    2016-01-01

    Make math fun with Subtract It! Fun photographs, colorful graphics, and simple text are used to teach young readers basic math concepts. From Word Problems to Number Lines this book will help kids develop the math skills they need. A simple activity at the end of the book encourages kids to put subtraction to use! Aligned to Common Core standards and correlated to state standards. Sandcastle is an imprint of Abdo Publishing, a division of ABDO.

  16. A digital technique for art authentication.

    Science.gov (United States)

    Lyu, Siwei; Rockmore, Daniel; Farid, Hany

    2004-12-07

    We describe a computational technique for authenticating works of art, specifically paintings and drawings, from high-resolution digital scans of the original works. This approach builds a statistical model of an artist from the scans of a set of authenticated works against which new works then are compared. The statistical model consists of first- and higher-order wavelet statistics. We show preliminary results from our analysis of 13 drawings that at various times have been attributed to Pieter Bruegel the Elder; these results confirm expert authentications. We also apply these techniques to the problem of determining the number of artists that may have contributed to a painting attributed to Pietro Perugino and again achieve an analysis agreeing with expert opinion.

  17. Utility of time-resolved three-dimensional magnetic resonance digital subtraction angiography without contrast material for assessment of intracranial dural arterio-venous fistula

    International Nuclear Information System (INIS)

    Hori, Masaaki; Aoki, Shigeki; Nakanishi, Atsushi; Shimoji, Keigo; Kamagata, Koji; Houshito, Haruyoshi; Kuwatsuru, Ryohei; Oishi, Hidenori; Arai, Hajime

    2011-01-01

    Background: Intracranial dural arteriovenous fistula (DAVF) is an arteriovenous shunting disease of the dura. Magnetic resonance angiography (MRA) is expected to be a safer alternative method in evaluation of DAVF, compared with invasive intra-arterial digital subtraction angiography (IADSA). Purpose: To evaluate the diagnostic use of time-spatial labeling inversion pulse (Time-SLIP) three-dimensional (3D) magnetic resonance digital subtraction angiography (MRDSA) without contrast material in six patients with DAVF. Material and Methods: Images for 3D time-of-flight MRA, which has been a valuable tool for the diagnosis of DAVF but provide little or less hemodynamic information, and Time-SLIP 3D MRDSA, were acquired for each patient. The presence, side, and grade of the disease were evaluated according to IADSA. Results: In all patients, the presence and side of the DAVF were correctly identified by both 3D time-of-flight MRA and Time-SLIP 3D MRDSA. Cortical reflux present in a patient with a grade 2b DAVF was not detected by Time-SLIP 3D MRDSA, when compared with IADSA findings. Conclusion: Time-SLIP 3D MRDSA provides hemodynamic information without contrast material and is a useful complementary tool for diagnosis of DAVF

  18. Digital techniques. Special issue; Digitale techniek. Themanummer

    Energy Technology Data Exchange (ETDEWEB)

    Rigter, L.J.M. [Siemens Nederland, Building Technologies, Den Haag (Netherlands); Meiring, O.; Hut, W. [Getronics Industrial Automation, Amsterdam (Netherlands); Van Dijk, K.W. [Van Dijk Woon-ICT Adviseur Domotica, Dordrecht (Netherlands); Aartman, M.J. [Siemens Nederland, Fire Safety, Den Haag (Netherlands); Spies, R.J. [Deerns raadgevende ingenieurs, Rijswijk (Netherlands); Burgers, H. [Honeywell, Amsterdam (Netherlands); Stouthart, F.J. [Merlijn Media, Waddinxveen (Netherlands); Van Gurp, J.P. [GTI Electroproject, Zaanstad (Netherlands); Draijer, G.W.

    2003-06-01

    In 11 articles several aspects of the principles and uses of digital techniques in buildings are highlighted: Building Automation and Control network (BACnet); trends in building automation and building management; technology and uses of domotics; developments and trends in fire alarm systems; control of thermal comfort (LonWorks); process control technology; use of internet in building management systems; and frequency control of indoor climate systems. [Dutch] In 11 artikelen wordt aandacht besteed aan de principes en het gebruik van digitale technieken in gebouwen: Building Automation and Control network (BACnet); gebouwautomatisering en gebouwbeheer nu en in de nabije toekomst; techniek, toepassing en uitvoering van domotica; ontwikkelingen en trends in brandmelders; het gebruik van LonWorks voor flexibele ruimtecomfortregelingen; digitale technieken in de meet- en regeltechniek; gebouwbeheerssytemen met geintegreerde internettechnologie; en frequentiegeregelde aandrijvingen voor de klimaattechniek.

  19. Accuracy and precision of polyurethane dental arch models fabricated using a three-dimensional subtractive rapid prototyping method with an intraoral scanning technique.

    Science.gov (United States)

    Kim, Jae-Hong; Kim, Ki-Baek; Kim, Woong-Chul; Kim, Ji-Hwan; Kim, Hae-Young

    2014-03-01

    This study aimed to evaluate the accuracy and precision of polyurethane (PUT) dental arch models fabricated using a three-dimensional (3D) subtractive rapid prototyping (RP) method with an intraoral scanning technique by comparing linear measurements obtained from PUT models and conventional plaster models. Ten plaster models were duplicated using a selected standard master model and conventional impression, and 10 PUT models were duplicated using the 3D subtractive RP technique with an oral scanner. Six linear measurements were evaluated in terms of x, y, and z-axes using a non-contact white light scanner. Accuracy was assessed using mean differences between two measurements, and precision was examined using four quantitative methods and the Bland-Altman graphical method. Repeatability was evaluated in terms of intra-examiner variability, and reproducibility was assessed in terms of inter-examiner and inter-method variability. The mean difference between plaster models and PUT models ranged from 0.07 mm to 0.33 mm. Relative measurement errors ranged from 2.2% to 7.6% and intraclass correlation coefficients ranged from 0.93 to 0.96, when comparing plaster models and PUT models. The Bland-Altman plot showed good agreement. The accuracy and precision of PUT dental models for evaluating the performance of oral scanner and subtractive RP technology was acceptable. Because of the recent improvements in block material and computerized numeric control milling machines, the subtractive RP method may be a good choice for dental arch models.

  20. Digital image processing techniques in archaeology

    Digital Repository Service at National Institute of Oceanography (India)

    Santanam, K.; Vaithiyanathan, R.; Tripati, S.

    Digital image processing involves the manipulation and interpretation of digital images with the aid of a computer. This form of remote sensing actually began in the 1960's with a limited number of researchers analysing multispectral scanner data...

  1. Digital watermarking and steganography fundamentals and techniques

    CERN Document Server

    Shih, Frank Y

    2007-01-01

    Introduction Digital Watermarking Digital Steganography Differences between Watermarking and Steganography A Brief History Appendix: Selected List of Books on Watermarking and Steganography Classification in Digital Watermarking Classification Based on Characteristics Classification Based on Applications Mathematical Preliminaries  Least-Significant-Bit Substitution Discrete Fourier Transform (DFT) Discrete Cosine Transform Discrete Wavelet Transform Random Sequence Generation  The Chaotic M

  2. Digital lock-in techniques for adaptive power-line interference extraction.

    Science.gov (United States)

    Dobrev, Dobromir; Neycheva, Tatyana; Mudrov, Nikolay

    2008-07-01

    This paper presents a simple digital approach for adaptive power-line (PL) or other periodic interference extraction. By means of two digital square (or sine) wave mixers, the real and imaginary parts of the interference are found, and the interference waveform is synthesized and finally subtracted. The described technique can be implemented in an open-loop architecture where the interference is synthesized as a complex sinusoid or in a closed-loop architecture for automatic phase and gain control. The same approach can be used for removal of the fundamental frequency of the PL interference as well as its higher harmonics. It is suitable for real-time operation with popular low-cost microcontrollers.

  3. Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Juan; Sun, Gang; Yu, Bling Bing; Li, Min; Li, Guo Ying; Peng, Zhao Hui; Zhang, Xu Ping [Dept. of Medical Imaging, Jinan Military General Hospital, Jinan (China); Lu, Yang [Dept. of Radiology, University of Illinois College of Medicine, Illinois (United States)

    2012-11-15

    To explore the usefulness of 320-slice CT angiography (CTA) for evaluating the course of the anterior ethmoidal artery (AEA) and its relationship with adjacent structures by using three-dimensional (3D) spin digital subtraction angiography (DSA) as standard reference. From December 2008 to December 2010, 32 patients with cerebrovascular disease, who underwent both cranial 3D spin DSA and 320-slice CTA within a 30 day period from each other, were retrospectively reviewed. AEA course in ethmoid was analyzed in DSA and CTA. In addition, adjacent bony landmarks (bony notch in medial orbital wall, anterior ethmoidal canal, and anterior ethmoidal sulcus) were evaluated with CTA using the MPR technique oriented along the axial, coronal and oblique coronal planes in all patients. The dose length product (DLP) for CTA and the dose-area product (DAP) for 3D spin DSA were recorded. Effective dose (ED) was calculated. The entire course of the AEA was seen in all 32 cases (100%) with 3D spine DSA and in 29 of 32 cases (90.1%) with 320-slice CTA, with no significant difference (p = 0.24). In three cases where AEA was not visualized on 320-slice CTA, two were due to the dominant posterior ethmoidal artery, while the remaining case was due to diminutive AEA. On MPR images of 320-slice CT, a bony notch in the orbital medial walls was detected in all cases (100%, 64 of 64); anterior ethmoidal canal was seen in 28 of 64 cases (43.8%), and the anterior ethmoidal sulcus was seen in 63 of 64 cases (98.4%). The mean effective dose in CTA was 0.6 {+-} 0.25 mSv, which was significantly lower than for 3D spin DSA (1.3 {+-} 0.01 mSv) (p < 0.001). 320-slice CTA has a similar detection rate for AEA to that of 3D spin DSA; however, it is noninvasive, and may be preferentially used for the evaluation of AEA and its adjacent bony variations and pathologic changes in preoperative patients with paranasal sinus diseases.

  4. Wavelet processing techniques for digital mammography

    Science.gov (United States)

    Laine, Andrew F.; Song, Shuwu

    1992-09-01

    This paper introduces a novel approach for accomplishing mammographic feature analysis through multiresolution representations. We show that efficient (nonredundant) representations may be identified from digital mammography and used to enhance specific mammographic features within a continuum of scale space. The multiresolution decomposition of wavelet transforms provides a natural hierarchy in which to embed an interactive paradigm for accomplishing scale space feature analysis. Similar to traditional coarse to fine matching strategies, the radiologist may first choose to look for coarse features (e.g., dominant mass) within low frequency levels of a wavelet transform and later examine finer features (e.g., microcalcifications) at higher frequency levels. In addition, features may be extracted by applying geometric constraints within each level of the transform. Choosing wavelets (or analyzing functions) that are simultaneously localized in both space and frequency, results in a powerful methodology for image analysis. Multiresolution and orientation selectivity, known biological mechanisms in primate vision, are ingrained in wavelet representations and inspire the techniques presented in this paper. Our approach includes local analysis of complete multiscale representations. Mammograms are reconstructed from wavelet representations, enhanced by linear, exponential and constant weight functions through scale space. By improving the visualization of breast pathology we can improve the chances of early detection of breast cancers (improve quality) while requiring less time to evaluate mammograms for most patients (lower costs).

  5. Application of digital image processing techniques to astronomical imagery 1977

    Science.gov (United States)

    Lorre, J. J.; Lynn, D. J.

    1978-01-01

    Nine specific techniques of combination of techniques developed for applying digital image processing technology to existing astronomical imagery are described. Photoproducts are included to illustrate the results of each of these investigations.

  6. Applying the digital-image-correlation technique to measure the ...

    Indian Academy of Sciences (India)

    digital-image-correlation) technique is used to measure the deformation of the retrofitted column. The result shows that the DIC technique can be successfully applied to measure the relative displacement of the column. Additionally, thismethod ...

  7. Fabrication of Thermoelectric Devices Using Additive-Subtractive Manufacturing Techniques: Application to Waste-Heat Energy Harvesting

    Science.gov (United States)

    Tewolde, Mahder

    Thermoelectric generators (TEGs) are solid-state devices that convert heat directly into electricity. They are well suited for waste-heat energy harvesting applications as opposed to primary energy generation. Commercially available thermoelectric modules are flat, inflexible and have limited sizes available. State-of-art manufacturing of TEG devices relies on assembling prefabricated parts with soldering, epoxy bonding, and mechanical clamping. Furthermore, efforts to incorporate them onto curved surfaces such as exhaust pipes, pump housings, steam lines, mixing containers, reaction chambers, etc. require custom-built heat exchangers. This is costly and labor-intensive, in addition to presenting challenges in terms of space, thermal coupling, added weight and long-term reliability. Additive manufacturing technologies are beginning to address many of these issues by reducing part count in complex designs and the elimination of sub-assembly requirements. This work investigates the feasibility of utilizing such novel manufacturing routes for improving the manufacturing process of thermoelectric devices. Much of the research in thermoelectricity is primarily focused on improving thermoelectric material properties by developing of novel materials or finding ways to improve existing ones. Secondary to material development is improving the manufacturing process of TEGs to provide significant cost benefits. To improve the device fabrication process, this work explores additive manufacturing technologies to provide an integrated and scalable approach for TE device manufacturing directly onto engineering component surfaces. Additive manufacturing techniques like thermal spray and ink-dispenser printing are developed with the aim of improving the manufacturing process of TEGs. Subtractive manufacturing techniques like laser micromachining are also studied in detail. This includes the laser processing parameters for cutting the thermal spray materials efficiently by

  8. Clinically useful dilution factors for iodine and gadolinium contrast material: an animal model of pediatric digital subtraction angiography using state-of-the-art flat-panel detectors.

    Science.gov (United States)

    Racadio, John M; Kashinkunti, Soumya R; Nachabe, Rami A; Racadio, Judy M; Johnson, Neil D; Kukreja, Kamlesh U; Patel, Manish N; Privitera, Mary Beth; Hales, Jasmine E; Abruzzo, Todd A

    2013-11-01

    Iodinated and gadolinium contrast agents pose some risk for certain pediatric patients, including allergic-like reactions, contrast-induced nephropathy (CIN) and nephrogenic systemic fibrosis (NSF). Digital flat-panel detectors enhance image quality during angiography and might allow use of more dilute contrast material to decrease risk of complications that might be dose-dependent, such as CIN and NSF. To assess the maximum dilution factors for iodine- and gadolinium-based contrast agents suitable for vascular imaging with fluoroscopy and digital subtraction angiography (DSA) on digital flat-panel detectors in an animal model. We performed selective catheterization of the abdominal aorta, renal artery and common carotid artery on a rabbit. In each vessel we performed fluoroscopy and DSA during contrast material injection using iodinated and gadolinium contrast material at 100%, 80%, 50%, 33% and 20% dilutions. An image quality score (0 to 3) was assigned by each of eight evaluators. Intracorrelation coefficient, paired t-test, one-way repeated analysis of variance, Spearman correlation and receiver operating characteristic curve analysis were applied to the data. Overall the image quality scores correlated linearly with dilution levels. For iodinated contrast material, the optimum cut-off level for DSA when a score of at least 2 is acceptable is above 33%; it is above 50% when a score of 3 is necessary. For gadolinium contrast material, the optimum cut-off for DSA images is above 50% when a score of at least 2 is acceptable and above 80% when a score of 3 is necessary. Knowledge of the relationship between image quality and contrast material dilution might allow a decrease in overall contrast load while maintaining appropriate image quality when using digital flat-panel detectors.

  9. Digital I and C system upgrade integration technique

    International Nuclear Information System (INIS)

    Huang, H. W.; Shih, C.; Wang, J. R.; Huang, K. C.

    2012-01-01

    This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure Events. A

  10. Digital processing optical transmission and coherent receiving techniques

    CERN Document Server

    Binh, Le Nguyen

    2013-01-01

    With coherent mixing in the optical domain and processing in the digital domain, advanced receiving techniques employing ultra-high speed sampling rates have progressed tremendously over the last few years. These advances have brought coherent reception systems for lightwave-carried information to the next stage, resulting in ultra-high capacity global internetworking. Digital Processing: Optical Transmission and Coherent Receiving Techniques describes modern coherent receiving techniques for optical transmission and aspects of modern digital optical communications in the most basic lines. The

  11. Contexts for Column Addition and Subtraction

    Science.gov (United States)

    Lopez Fernandez, Jorge M.; Velazquez Estrella, Aileen

    2011-01-01

    In this article, the authors discuss their approach to column addition and subtraction algorithms. Adapting an original idea of Paul Cobb and Erna Yackel's from "A Contextual Investigation of Three-Digit Addition and Subtraction" related to packing and unpacking candy in a candy factory, the authors provided an analogous context by…

  12. New Noise Subtraction Methods in Lattice QCD

    OpenAIRE

    Baral, Suman; Wilcox, Walter; Morgan, Ronald B.

    2016-01-01

    Noise subtraction techniques can help reduce the statistical uncertainty in the extraction of hard to detect signals. We describe new noise subtraction methods in Lattice QCD which apply to disconnected diagram evaluations. Some of the noise suppression techniques include polynomial quark matrix methods, eigenspectrum deflation methods, and combination methods. Our most promising technique combines polynomial and Hermitian deflation subtraction methods. The overall goal is to improve the effi...

  13. Suppression subtraction hybridization (SSH) and macroarray techniques reveal differential gene expression profiles in brain of sea bream infected with nodavirus.

    Science.gov (United States)

    Dios, S; Poisa-Beiro, L; Figueras, A; Novoa, B

    2007-03-01

    Despite of the impact that viruses have on aquatic organisms, relatively little is known on how fish fight against these infections. In this work, the brain gene expression pattern of sea bream (Sparus aurata) in response to nodavirus infection was investigated. We used the suppression subtractive hybridization (SSH) method to generate a subtracted cDNA library enriched with gene transcripts differentially expressed after 1 day post-infection. Some of the ESTs from the infected tissues fell in gene categories related to stress and immune responses. For the reverse library (ESTs expressed in controls compared with infected tissues) the most abundant transcripts were of ribosomal and mitochondrial nature. Several ESTs potentially induced by virus exposure were selected for in vivo expression studies. We observed a clear difference in expression between infected and control samples for two candidate genes, ubiquitin conjugating enzyme 7 interacting protein, which seems to play an important role in apoptosis and the interferon induced protein with helicase C domain 1 (mda-5) that contributes to apoptosis and regulates the type I IFN production, a key molecule of the antiviral innate response in most organisms.

  14. Four-dimensional CT angiography (4D-CTA) in the evaluation of juvenile nasopharyngeal angiofibromas: comparison with digital subtraction angiography (DSA) and surgical findings.

    Science.gov (United States)

    Xiao, Zebin; Zheng, Yingyan; Li, Jian; Chen, Dehua; Liu, Fang; Cao, Dairong

    2017-12-01

    To explore the value of four-dimensional CT angiography (4D-CTA) in the preoperative evaluation of juvenile nasopharyngeal angiofibromas (JNAs) using 320-row volume CT. 4D-CTA and DSA data of 18 patients with histopathologically proven JNAs were retrospectively reviewed. The location, extent, feeding vessels and stage of JNAs were assessed by two radiologists independently and blindly. The agreements between both reviewers and between 4D-CTA and surgical findings for assessing the above indicators were analysed, respectively. The radiation dose and the number of feeding arteries between 4D-CTA and digital subtraction angiography (DSA) were also compared. 4D-CTA showed high diagnostic consistency with surgical pathology for JNAs with consistent rates of 96.2 and 100% in both reviewers, respectively. The effective dose of 4D-CTA was significantly less than that of DSA (p 0.05). 4D-CTA can provide a reliable preoperative diagnosis and assessment of JNAs, which is useful for determining the surgical strategy and management of this condition.

  15. Dual-energy CT head bone and hard plaque removal for quantification of calcified carotid stenosis: utility and comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Uotani, Kensuke; Watanabe, Yoshiyuki; Higashi, Masahiro; Nakazawa, Tetsuro; Kono, Atsushi K.; Hori, Yoshiro; Fukuda, Tetsuya; Kanzaki, Suzu; Yamada, Naoaki; Naito, Hiroaki; Itoh, Toshihide; Sugimura, Kazuro

    2009-01-01

    We evaluated quantification of calcified carotid stenosis by dual-energy (DE) CTA and dual-energy head bone and hard plaque removal (DE hard plaque removal) and compared the results to those of digital subtraction angiography (DSA). Eighteen vessels (13 patients) with densely calcified carotid stenosis were examined by dual-source CT in the dual-energy mode (tube voltages 140 kV and 80 kV). Head bone and hard plaques were removed from the dual-energy images by using commercial software. Carotid stenosis was quantified according to NASCET criteria on MIP images and DSA images at the same plane. Correlation between DE CTA and DSA was determined by cross tabulation. Accuracies for stenosis detection and grading were calculated. Stenosis could be evaluated in all vessels by DE CTA after applying DE hard plaque removal. In contrast, conventional CTA failed to show stenosis in 13 out of 18 vessels due to overlapping hard plaque. Good correlation between DE plaque removal images and DSA images was observed (r 2 =0.9504) for stenosis grading. Sensitivity and specificity to detect hemodynamically relevant (>70%) stenosis was 100% and 92%, respectively. Dual-energy head bone and hard plaque removal is a promising tool for the evaluation of densely calcified carotid stenosis. (orig.)

  16. The value of magnetic resonance imaging for the detection of the bleeding source in non-traumatic intracerebral haemorrhages: a comparison with conventional digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Lummel, Nina; Lutz, Juergen; Brueckmann, Hartmut; Linn, Jennifer [University of Munich, Department of Neuroradiology, Munich (Germany)

    2012-07-15

    Conventional digital subtraction angiography (DSA) is currently regarded as the gold standard in detecting underlying vascular pathologies in patients with intracerebral haemorrhages (ICH). However, the use of magnetic resonance imaging (MRI) in the diagnostic workup of ICHs has considerably increased in recent years. Our aim was to evaluate the diagnostic accuracy and yield of MRI for the detection of the underlying aetiology in ICH patients. Sixty-seven consecutive patients with an acute ICH who underwent MRI (including magnetic resonance angiography (MRA) and DSA during their diagnostic workup) were included in the study. Magnetic resonance images were retrospectively analysed by two independent neuroradiologists to determine the localisation and cause of the ICH. DSA was used as a reference standard. In seven patients (10.4%), a DSA-positive vascular aetiology was present (one aneurysm, four arteriovenous malformations, one dural arteriovenous fistula and one vasculitis). All of these cases were correctly diagnosed by both readers on MRI. In addition, MRI revealed the following probable bleeding causes in 39 of the 60 DSA-negative patients: cerebral amyloid angiopathy (17), cavernoma (9), arterial hypertension (8), haemorrhagic transformation of an ischaemic infarction (3) and malignant brain tumour with secondary ICH (2). Performing MRI with MRA proved to be an accurate diagnostic tool in detecting vascular malformations in patients with ICH. In addition, MRI provided valuable information regarding DSA-negative ICH causes, and thus had a high diagnostic yield in ICH patients. (orig.)

  17. Gadobutrol-enhanced moving-table magnetic resonance angiography in patients with peripheral vascular disease: a prospective, multi-centre blinded comparison with digital subtraction angiography

    Energy Technology Data Exchange (ETDEWEB)

    Hentsch, Annette [Schering AG, Berlin (Germany); Aschauer, Manuela A.; Ebner, Franz [Department of Magnetic Resonance, University of Graz, Graz (Austria); Balzer, Joern O.; Davis, Kirsten [Department of Diagnostic and Interventional Radiology, University of Frankfurt/Main, Frankfurt/Main (Germany); Brossmann, Joachim; Schaefer, Fritz K.W. [Department of Diagnostic Radiology, University of Kiel, Kiel (Germany); Busch, Hans P. [Krankenhaus der Barmherzigen Brueder, Trier (Germany); Douek, Philippe [Department of Diagnostic Radiology, University of Lyon (France); Engelshoven, Jos M.A. van; Leiner, Tim [Department of Radiology, Cardiovascular Research Institute, University of Maastricht, Maastricht (Netherlands); Gregor, Michaela; Reimer, Peter [Department of Radiology, Staedtisches Klinikum, Karlsruhe (Germany); Kersting, Christian [Department of Diagnostic Radiology, University of Muenster, Muenster (Germany); Knuesel, Patrick R. [Institute of Diagnostic Radiology, University Hospital Zurich, MRI Center, Zurich (Switzerland); Leen, Edward [Department of X-ray, Glasgow Royal Infirmary, Glasgow (United Kingdom); Loewe, Christian; Thurnher, Siegfried A. [Section of Angiography and Interventional Radiology, Department of Radiology' ' University of Vienna, Vienna (Austria); McPherson, Simon [Department of Radiology, University of Leeds, Leeds (United Kingdom); Taupitz, Matthias [Department of Radiology, Humboldt University of Berlin (Charite), Berlin (Germany); Tombach, Bernd; Wegener, Robin; Weishaupt, Dominik; Meaney, James F.M.

    2003-09-01

    The purpose of this study was to compare moving-table three-dimensional contrast-enhanced magnetic resonance angiography (CE MRA), using 1.0-mol gadobutrol, with intra-arterial digital subtraction angiography (i.a. DSA) for evaluation of pelvic and peripheral arteries in patients with peripheral arterial occlusive disease. A total of 203 patients were examined in a prospective, multi-centre study at 1.0/1.5 T. Ten vessel segments of one leg were evaluated on-site and by three independent blinded reviewers off-site. One hundred eighty-two patients were evaluable in blinded reading. For pelvis and thigh, there was statistically significant diagnostic agreement between CE MRA and i.a. DSA on-site (94%) and off-site (86-88%). Overall, for detection of clinically significant stenoses, 93% sensitivity and 90% specificity were achieved in on-site evaluation, with 71-76 and 87-93% off-site; for detection of occlusion, sensitivity and specificity on-site were 91 and 97%, with 75-82 and 94-98% off-site. Evaluation was more sensitive on-site than off-site for detection of stenoses and occlusion, whereas specificity was similar. The CE MRA with 1.0-mol gadobutrol gave results comparable to those of i.a. DSA for the larger arteries of pelvis and thigh. Results for calf arteries were compromised by spatial resolution and technical limitations. (orig.)

  18. Integration technique of digital I and C replacement and its Critical Digital Review procedure

    International Nuclear Information System (INIS)

    Huang, Hui-Wen; Yang, Wen-Long

    2013-01-01

    Highlights: ► A digital I and C replacement integration technique have been developed. ► Establishment of Nuclear Power Plant Digital Replacement Integration Guideline. ► Preliminary Investigation on I and C System Digitalization. ► Evaluation on I and C System Digitalization. ► Establishment of I and C System Digitalization Architectures. -- Abstract: Institute of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin–Shan (CS) NPP, Kuo–Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) procedure. The digital I and C replacement integration technique includes: (1) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR-1011710 (2005) “Handbook for Evaluating Critical Digital Equipment and Systems” which was published by the Electric Power Research Institute (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SV and V), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of

  19. Advanced techniques in digital mammographic images recognition

    International Nuclear Information System (INIS)

    Aliu, R. Azir

    2011-01-01

    Computer Aided Detection and Diagnosis is used in digital radiography as a second thought in the process of determining diagnoses, which reduces the percentage of wrong diagnoses of the established interpretation of mammographic images. The issues that are discussed in the dissertation are the analyses and improvement of advanced technologies in the field of artificial intelligence, more specifically in the field of machine learning for solving diagnostic problems and automatic detection of speculated lesions in digital mammograms. The developed of SVM-based ICAD system with cascade architecture for analyses and comparison mammographic images in both projections (CC and MLO) gives excellent result for detection and masses and microcalcifications. In order to develop a system with optimal performances of sensitivity, specificity and time complexity, a set of relevant characteristics need to be created which will show all the pathological regions that might be present in the mammographic image. The structure of the mammographic image, size and the large number of pathological structures in this area are the reason why the creation of a set of these features is necessary for the presentation of good indicators. These pathological structures are a real challenge today and the world of science is working in that direction. The doctoral dissertation showed that the system has optimal results, which are confirmed by experts, and institutions, which are dealing with these same issues. Also, the thesis presents a new approach for automatic identification of regions of interest in the mammographic image where regions of interest are automatically selected for further processing mammography in cases when the number of examined patients is higher. Out of 480 mammographic images downloaded from MIAS database and tested with ICAD system the author shows that, after separation and selection of relevant features of ICAD system the accuracy is 89.7% (96.4% for microcalcifications

  20. TU-CD-207-03: Time Evolution of Texture Parameters of Subtracted Images Obtained by Contrast-Enhanced Digital Mammography (CEDM)

    Energy Technology Data Exchange (ETDEWEB)

    Mateos, M-J; Brandan, M-E [Instituto de Fisica, Universidad Nacional Autonom de Mexico, Mexico, Distrito Federal (Mexico); Gastelum, A; Marquez, J [Centro de Ciencias Aplicadas y Desarrollo Tecnologico Universidad Nacional Autonoma de Mexico, Mexico, Distrito Federal (Mexico)

    2015-06-15

    Purpose: To evaluate the time evolution of texture parameters, based on the gray level co-occurrence matrix (GLCM), in subtracted images of 17 patients (10 malignant and 7 benign) subjected to contrast-enhanced digital mammography (CEDM). The goal is to determine the sensitivity of texture to iodine uptake at the lesion, and its correlation (or lack of) with mean-pixel-value (MPV). Methods: Acquisition of clinical images followed a single-energy CEDM protocol using Rh/Rh/48 kV plus external 0.5 cm Al from a Senographe DS unit. Prior to the iodine-based contrast medium (CM) administration a mask image was acquired; four CM images were obtained 1, 2, 3, and 5 minutes after CM injection. Temporal series were obtained by logarithmic subtraction of registered CM minus mask images.Regions of interest (ROI) for the lesion were drawn by a radiologist and the texture was analyzed. GLCM was evaluated at a 3 pixel distance, 0° angle, and 64 gray-levels. Pixels identified as registration errors were excluded from the computation. 17 texture parameters were chosen, classified according to similarity into 7 groups, and analyzed. Results: In all cases the texture parameters within a group have similar dynamic behavior. Two texture groups (associated to cluster and sum mean) show a strong correlation with MPV; their average correlation coefficient (ACC) is r{sup 2}=0.90. Other two groups (contrast, homogeneity) remain constant with time, that is, a low-sensitivity to CM uptake. Three groups (regularity, lacunarity and diagonal moment) are sensitive to CM uptake but less correlated with MPV; their ACC is r{sup 2}=0.78. Conclusion: This analysis has shown that, at least groups associated to regularity, lacunarity and diagonal moment offer dynamical information additional to the mean pixel value due to the presence of CM at the lesion. The next step will be the analysis in terms of the lesion pathology. Authors thank PAPIIT-IN105813 for support. Consejo Nacional de Ciencia Y

  1. Quantitative Real-Time Fluoroscopy Analysis on Measurement of the Hepatic Arterial Flow During Transcatheter Arterial Chemoembolization of Hepatocellular Carcinoma: Comparison with Quantitative Digital Subtraction Angiography Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Yi-Yang; Lee, Rheun-Chuan, E-mail: rclee@vghtpe.gov.tw; Guo, Wan-Yuo, E-mail: wyguo@vghtpe.gov.tw; Chu, Wei-Fa [Taipei Veterans General Hospital, Department of Radiology (China); Wu, Frank Chun-Hsien [Siemens Healthcare Ltd. (China); Gehrisch, Sonja [Siemens Healthcare GmbH (Germany)

    2016-11-15

    PurposeTo quantify the arterial flow change during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using digital subtraction angiography, quantitative color-coding analysis (d-QCA), and real-time subtraction fluoroscopy QCA (f-QCA).Materials and MethodsThis prospective study enrolled 20 consecutive patients with HCC who had undergone TACE via a subsegmental approach between February 2014 and April 2015. The TACE endpoint was a sluggish antegrade tumor-feeding arterial flow. d-QCA and f-QCA were used for determining the relative maximal density time (rT{sub max}) of the selected arteries. The rT{sub max} of the selected arteries was analyzed in d-QCA and f-QCA before and after TACE, and its correlation in both analyses was evaluated.ResultsThe pre- and post-TACE rT{sub max} of the embolized segmental artery in d-QCA and f-QCA were 1.59 ± 0.81 and 2.97 ± 1.80 s (P < 0.001) and 1.44 ± 0.52 and 2.28 ± 1.02 s (P < 0.01), respectively. The rT{sub max} of the proximal hepatic artery did not significantly change during TACE in d-QCA and f-QCA. The Spearman correlation coefficients of the pre- and post-TACE rT{sub max} of the embolized segmental artery between d-QCA and f-QCA were 0.46 (P < 0.05) and 0.80 (P < 0.001). Radiation doses in one series of d-QCA and f-QCA were 140.7 ± 51.5 milligray (mGy) and 2.5 ± 0.7 mGy, respectively.Conclusionsf-QCA can quantify arterial flow changes with a higher temporal resolution and lower radiation dose. Flow quantification of the embolized segmental artery using f-QCA and d-QCA is highly correlated.

  2. Renogram and deconvolution parameters in diagnosis of renal artery stenosis. Variants of background subtraction and analysis techniques

    Energy Technology Data Exchange (ETDEWEB)

    Kempi, V. [Dept. of Clinical Physiology, Sjukhuset, Oestersund (Sweden)

    2007-07-01

    Aim: Multivariate statistical methods can be used for objective analysis. The emphasis is on analysing renal function parameters together, not one at a time. The aim is to identify curve parameters useful in making predictions in kidneys with and without renal artery stenosis (RAS). Patients, methods: 68 patients with resistant hypertension were subjected to captopril renography with {sup 99m}Tc-DTPA. Variants of background areas and background subtraction methods were employed. A correction was applied for loss of renal parenchyma. Parameters from time-activity curves and retention curves from deconvolution were calculated. Renal angiography established the presence or absence of RAS. Logistic regression analysis, using age- and kidney size-adjusted models, was performed to assess the capability of renography and deconvolution to differentiate between kidneys with and without RAS. Results: Discrimination between normal kidneys and RAS was achieved by deconvolution and by renography. Deconvolution was the method of first rank with a sensitivity of 87% and a specificity of 98%. For separation of RAS and kidneys with parenchymal insufficiency deconvolution was the method of first rank with a sensitivity of 80% and specificity of 89%, whereas renography produced poor results. Conclusion: The best performance with {sup 99m}Tc-DTPA was based on normalised background subtraction using a rectangular area between the kidneys. Deconvolution produced the most favourable results in the separation of kidneys with and without RAS. For separation of RAS and kidneys with parenchymal insufficiency conventional renography produced poor results. Conceptually, the results of a logistic regression analysis of renal function parameters may raise possibilities in the field of computer-aided diagnosis. (orig.)

  3. Application of digital gammagraphy techniques to steel

    International Nuclear Information System (INIS)

    Dumont-Fillon, J.; Gauje, P.; Wanin, M.

    1982-01-01

    To reveal certain defects in steel by gammagraphy, it is possible to use an electronic detector measuring the transmitted flux point by point. In order to improve the performance of these techniques, the use of multiple detectors is being investigated to facilitate the mapping of flaws in the inspection of large-section products. In this connection, we have developed an experimental test bench designed to elucidate the applicable measurement conditions. We have investigated more particularly the evolution of the volume of the limit detectable fault according to the geometrical measurement parameters. An attempt is also being made to transpose tomographical techniques to the examination of small steel specimens [fr

  4. Assessment of the left ventricular systolic and diastolic function by the left ventricular density curve derived from intravenous digital subtraction angiography in children

    Energy Technology Data Exchange (ETDEWEB)

    Horigome, Hitoshi; Satoh, Hideo; Isobe, Takeshi; Takita, Hitoshi (Tsukuba Univ., Ibaraki (Japan). Inst. of Clinical Medicine)

    1991-05-01

    To evaluate the left ventricular (LV) systolic and diastolic function, fifty-four children with various heart diseases underwent intravenous digital subtraction angiography (IV-DSA). Global left ventricular density curve was obtained through densitometry of the DSA images. The curve was smoothed by a third-degree Fourier transformation and systolic and diastolic indexes were obtained. In the control group, consisting of Kawasaki disease without coronary lesion and mild pulmonary stenosis, the peak ejection rate (PER) and the peak filling rate in early diastole (PFR-E) correlated positively with the heart rate (HR) in a quadratic curve manner (PER: r= 0.93 p<0.01, PFR-E: r= 0.94 p<0.01). Time from end-diastolic to PER (T-PER) and time from end-systolic to PFR (T-PFR) were correlated negatively with HR (T-PER: r=-0.86 p<0.01, T-PFR: r=-0.91 p<0.01). However, T-PER/RR and T-PFR/RR values were rather constant (20.9+-3.2%, 17.0+-2.6%, respectively). We also found significant correlations of PER and PFR-E with left ventricular ejection fraction (LVEF). Patients with corrected tetralogy of Fallot and with cardiomyopaties showed not only abnormal systolic indexes but some depressed diastolic indexes. LV density curve also disclosed isolated diastolic dysfunction in a group of aortic stenosis and in two patients with coronary lesions. A correlation of LVEF derived from the density curve and conventional area-length method was high (r= 0.91 p<0.001). To evaluate the reproducibility, we were able to obtain the digital data twice with over one month interval on 24 patients. The intraobserver correlation was satisfactory. We applied the remasking method, resulting in improving the quality of digital images under spontaneous breathing. Our results indicated that IV-DSA was a less-invasive and clinically reliable method for assessment of LV function in children. (author).

  5. Assessment of the left ventricular systolic and diastolic function by the left ventricular density curve derived from intravenous digital subtraction angiography in children

    International Nuclear Information System (INIS)

    Horigome, Hitoshi; Satoh, Hideo; Isobe, Takeshi; Takita, Hitoshi

    1991-01-01

    To evaluate the left ventricular (LV) systolic and diastolic function, fifty-four children with various heart diseases underwent intravenous digital subtraction angiography (IV-DSA). Global left ventricular density curve was obtained through densitometry of the DSA images. The curve was smoothed by a third-degree Fourier transformation and systolic and diastolic indexes were obtained. In the control group, consisting of Kawasaki disease without coronary lesion and mild pulmonary stenosis, the peak ejection rate (PER) and the peak filling rate in early diastole (PFR-E) correlated positively with the heart rate (HR) in a quadratic curve manner [PER: r= 0.93 p<0.01, PFR-E: r= 0.94 p<0.01]. Time from end-diastolic to PER (T-PER) and time from end-systolic to PFR (T-PFR) were correlated negatively with HR [T-PER: r=-0.86 p<0.01, T-PFR: r=-0.91 p<0.01]. However, T-PER/RR and T-PFR/RR values were rather constant (20.9±3.2%, 17.0±2.6%, respectively). We also found significant correlations of PER and PFR-E with left ventricular ejection fraction (LVEF). Patients with corrected tetralogy of Fallot and with cardiomyopaties showed not only abnormal systolic indexes but some depressed diastolic indexes. LV density curve also disclosed isolated diastolic dysfunction in a group of aortic stenosis and in two patients with coronary lesions. A correlation of LVEF derived from the density curve and conventional area-length method was high [r= 0.91 p<0.001]. To evaluate the reproducibility, we were able to obtain the digital data twice with over one month interval on 24 patients. The intraobserver correlation was satisfactory. We applied the remasking method, resulting in improving the quality of digital images under spontaneous breathing. Our results indicated that IV-DSA was a less-invasive and clinically reliable method for assessment of LV function in children. (author)

  6. Cloud computing and digital media fundamentals, techniques, and applications

    CERN Document Server

    Li, Kuan-Ching; Shih, Timothy K

    2014-01-01

    Cloud Computing and Digital Media: Fundamentals, Techniques, and Applications presents the fundamentals of cloud and media infrastructure, novel technologies that integrate digital media with cloud computing, and real-world applications that exemplify the potential of cloud computing for next-generation digital media. It brings together technologies for media/data communication, elastic media/data storage, security, authentication, cross-network media/data fusion, interdevice media interaction/reaction, data centers, PaaS, SaaS, and more.The book covers resource optimization for multimedia clo

  7. improvement of digital image watermarking techniques based on FPGA implementation

    International Nuclear Information System (INIS)

    EL-Hadedy, M.E

    2006-01-01

    digital watermarking provides the ownership of a piece of digital data by marking the considered data invisibly or visibly. this can be used to protect several types of multimedia objects such as audio, text, image and video. this thesis demonstrates the different types of watermarking techniques such as (discrete cosine transform (DCT) and discrete wavelet transform (DWT) and their characteristics. then, it classifies these techniques declaring their advantages and disadvantages. an improved technique with distinguished features, such as peak signal to noise ratio ( PSNR) and similarity ratio (SR) has been introduced. the modified technique has been compared with the other techniques by measuring heir robustness against differ attacks. finally, field programmable gate arrays (FPGA) based implementation and comparison, for the proposed watermarking technique have been presented and discussed

  8. Digital audio watermarking fundamentals, techniques and challenges

    CERN Document Server

    Xiang, Yong; Yan, Bin

    2017-01-01

    This book offers comprehensive coverage on the most important aspects of audio watermarking, from classic techniques to the latest advances, from commonly investigated topics to emerging research subdomains, and from the research and development achievements to date, to current limitations, challenges, and future directions. It also addresses key topics such as reversible audio watermarking, audio watermarking with encryption, and imperceptibility control methods. The book sets itself apart from the existing literature in three main ways. Firstly, it not only reviews classical categories of audio watermarking techniques, but also provides detailed descriptions, analysis and experimental results of the latest work in each category. Secondly, it highlights the emerging research topic of reversible audio watermarking, including recent research trends, unique features, and the potentials of this subdomain. Lastly, the joint consideration of audio watermarking and encryption is also reviewed. With the help of this...

  9. Comparing indocyanine green videoangiography to the gold standard of intraoperative digital subtraction angiography used in aneurysm surgery.

    Science.gov (United States)

    Washington, Chad W; Zipfel, Gregory J; Chicoine, Michael R; Derdeyn, Colin P; Rich, Keith M; Moran, Christopher J; Cross, DeWitte T; Dacey, Ralph G

    2013-02-01

    The purpose of aneurysm surgery is complete aneurysm obliteration while sparing associated arteries. Indocyanine green (ICG) videoangiography is a new technique that allows for real-time evaluation of blood flow in the aneurysm and vessels. The authors performed a retrospective study to compare the accuracy of ICG videoangiography with intraoperative angiography (IA), and determine if ICG videoangiography can be used without follow-up IA. From June 2007 through September 2009, 155 patients underwent craniotomies for clipping of aneurysms. Operative summaries, angiograms, and operative and ICG videoangiography videos were reviewed. The number, size, and location of aneurysms, the ICG videoangiography and IA findings, and the need for clip adjustment after ICG videoangiography and IA were recorded. Discordance between ICG videoangiography and IA was defined as ICG videoangiography demonstrating aneurysm obliteration and normal vessel flow, but post-IA showing either an aneurysmal remnant and/or vessel occlusion requiring clip adjustment. Thirty-two percent of patients (49 of 155) underwent both ICG videoangiography and IA. The post-ICG videoangiography clip adjustment rate was 4.1% (2 of 49). The overall rate of ICG videoangiography-IA agreement was 75.5% (37 of 49) and the ICG videoangiography-IA discordance rate requiring post-IA clip adjustment was 14.3% (7 of 49). Adjustments were due to 3 aneurysmal remnants and 4 vessel occlusions. These adjustments were attributed to obscuration of the residual aneurysm or the affected vessel from the field of view and the presence of dye in the affected vessel via collateral flow. Although not statistically significant, there was a trend for ICG videoangiography-IA discordance requiring clip adjustment to occur in cases involving the anterior communicating artery complex, with an odds ratio of 3.3 for ICG videoangiography-IA discordance in these cases. These results suggest that care should be taken when considering ICG

  10. Gadolinium-DTPA-enhanced and digitally subtracted magnetic resonance imaging of estrogen-induced pituitary lesions in rats: correlation with pituitary anatomy.

    Science.gov (United States)

    van Nesselrooij, J H; Szeverenyi, N M; Tillapaugh-Fay, G M; Hendriksen, F G

    1990-01-01

    Pituitary hypertrophy and tumors were induced in male Sprague Dawley rats using estradiol-17 beta. This tumor model generates a variety of pituitary lesions which are relevant to human pituitary disease. In order to characterize these lesions, gadolinium DTPA was injected intravenously into the tail vein of estrogen treated and control rats. High resolution T1-weighted MR images, pre- and postenhancement, were obtained at 8 different time points spanning 300 days following the subcutaneous implantation of the estrogen pellets. Images with 2-mm slice thickness were made with a 2 Telsa small-bore MR imaging system. Both normal and tumorous pituitaries were found to enhance with contrast agent, but contrast uptake was not uniform. Gd-DTPA distribution was sensitive to the different types of lesions generated in the course of this study. Digital subtraction of congruent images, pre- and postcontrast, provided difference images reflecting contrast concentration and allowed identification of subtle enhancement effects. Hypertrophic pituitaries displayed uptake of contrast, but the distribution of contrast agent was nonuniform and appeared mottled. A bright rim enhancement was often seen anterior to the pituitary gland, most likely arising from the oculomotor nerves and arachnoid. Histological slices in the same anatomical plane as the MR images were obtained on the animals allowing identification of individual lesions. Cystic areas within tumors were found to give strong contrast enhancement in less than five min postinjection. Solid and hemorrhagic areas of the pituitary tumor were hypo- to isointense relative to surrounding brain and did not take up contrast agent. Significant perfusion in these areas apparently does not occur.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Quantitative perfusion computed tomography measurements of cerebral hemodynamics: Correlation with digital subtraction angiography identified primary and secondary cerebral collaterals in internal carotid artery occlusive disease

    International Nuclear Information System (INIS)

    Cheng Xiaoqing; Tian Jianming; Zuo Changjing; Liu Jia; Zhang Qi; Lu Guangming

    2012-01-01

    Background: The aim of the present study was to assess hemodynamic variations in symptomatic unilateral internal carotid artery occlusion (ICAO) patients with primary collateral flow via circle of Willis or secondary collateral flow via ophthalmic artery and/or leptomeningeal collaterals. Methods: Thirty-eight patients with a symptomatic unilateral ICAO were enrolled in the study. Based on digital subtraction angiography (DSA) findings, patients were classified into 2 groups: primary collateral (n = 14) and secondary collateral (n = 24) groups. Collateral flow hemodynamics were investigated with perfusion computed tomography (PCT) by measuring the cerebral blood flow (CBF), cerebral blood volume (CBV) and time to peak (TTP) in the hemispheres ipsilateral and contralateral to ICAO. Based on the measurements, the ipsilateral to contralateral ratio for each parameter was calculated and compared. Results: Irrespective of the collateral patterns, ipsilateral CBF was not significantly different from that of the contralateral hemisphere (P = 0.285); ipsilateral CBV and TTP was significantly increased compared with those of the contralateral hemisphere (P = 0.000 and P = 0.000 for CBV and TTP, respectively). Furthermore, patients with secondary collaterals had significantly larger ipsilateral-to-contralateral ratios for both CBV (rCBV, P = 0.0197) and TTP (rTTP, P = 0.000) than those of patients with only primary collaterals. These two groups showed no difference in ipsilateral-to-contralateral ratio for CBF (rCBF, P = 0.312). Conclusion: Patients with symptomatic unilateral ICAO in our study were in an autoregulatory vasodilatation status. Moreover, secondary collaterals in ICAO patients were correlated with ipsilateral CBV and delayed TTP that suggested severe hemodynamic impairment, presumably increasing the risk of ischemic events.

  12. D Digital Simulation of Minnan Temple Architecture CAISSON'S Craft Techniques

    Science.gov (United States)

    Lin, Y. C.; Wu, T. C.; Hsu, M. F.

    2013-07-01

    Caisson is one of the important representations of the Minnan (southern Fujian) temple architecture craft techniques and decorative aesthetics. The special component design and group building method present the architectural thinking and personal characteristics of great carpenters of Minnan temple architecture. In late Qing Dynasty, the appearance and style of caissons of famous temples in Taiwan apparently presented the building techniques of the great carpenters. However, as the years went by, the caisson design and craft techniques were not fully inherited, which has been a great loss of cultural assets. Accordingly, with the caisson of Fulong temple, a work by the well-known great carpenter in Tainan as an example, this study obtained the thinking principles of the original design and the design method at initial period of construction through interview records and the step of redrawing the "Tng-Ko" (traditional design, stakeout and construction tool). We obtained the 3D point cloud model of the caisson of Fulong temple using 3D laser scanning technology, and established the 3D digital model of each component of the caisson. Based on the caisson component procedure obtained from interview records, this study conducted the digital simulation of the caisson component to completely recode and present the caisson design, construction and completion procedure. This model of preserving the craft techniques for Minnan temple caisson by using digital technology makes specific contribution to the heritage of the craft techniques while providing an important reference for the digital preservation of human cultural assets.

  13. Digital holography and wavefront sensing principles, techniques and applications

    CERN Document Server

    Schnars, Ulf; Watson, John; Jüptner, Werner

    2015-01-01

    This book presents a self-contained treatment of the principles and major applications of digital hologram recording and numerical reconstruction (Digital Holography). This second edition has been significantly revised and enlarged. The authors have extended the chapter on Digital Holographic Microscopy to incorporate new sections on particle sizing, particle image velocimetry and underwater holography. A new chapter now deals comprehensively and extensively with computational wave field sensing. These techniques represent a fascinating alternative to standard interferometry and Digital Holography. They enable wave field sensing without the requirement of a particular reference wave, thus allowing the use of low brilliance light sources and even liquid-crystal displays (LCD) for interferometric applications.              

  14. Ultrasonic imaging in LMFBRs using digital techniques

    International Nuclear Information System (INIS)

    Fothergill, J.R.; McKnight, J.A.; Barrett, L.M.

    Ultrasonic technology for providing images of components immersed in the opaque sodium of LMFBRs is being developed at RNL. For many years the application has been restricted by the unavailability of convenient ultrasonic sources and receivers capable of withstanding the reactor environment. Until recently, for example, important ultrasonic instrument design, such as for future sweep arms, had to be based on waveguided ultrasonics. RNL have developed an economic immersible transducer that can be deployed during reactor shut-down, when many demands for ultrasonic imaging are made. The transducer design is not suited at present to the sophisticated techniques of phased arrays; consequently image formation must depend on the physical scanning of a target using one or more transducers in pulse-echo mode. The difficulties of access into a fast reactor impose further restrictions. Some applications may involve easy scanning sequences, thus the sweep arm requires only a rotation to provide a map of the reactor core area. For a more detailed examination of the same area, however, special engineering solutions are needed to provide a more satisfactory scanning sequence. A compromise solution involving the rotating shield movement is being used for a PFR experiment to examine a limited area of the core. (author)

  15. Parallel phase-shifting digital holography using spectral estimation technique.

    Science.gov (United States)

    Xia, Peng; Awatsuji, Yasuhiro; Nishio, Kenzo; Ura, Shogo; Matoba, Osamu

    2014-09-20

    We propose a parallel phase-shifting digital holography using a spectral estimation technique, which enables the instantaneous acquisition of spectral information and three-dimensional (3D) information of a moving object. In this technique, an interference fringe image that contains six holograms with two phase shifts for three laser lines, such as red, green, and blue, is recorded by a space-division multiplexing method with single-shot exposure. The 3D monochrome images of these three laser lines are numerically reconstructed by a computer and used to estimate the spectral reflectance distribution of object using a spectral estimation technique. Preliminary experiments demonstrate the validity of the proposed technique.

  16. Application of digital-image-correlation techniques in analysing ...

    Indian Academy of Sciences (India)

    experimental results obtained using the digital image correlation analysis is used to demonstrate the crack development ... of applying DIC technique to monitor pipeline cracks is tested in this research by designing and applying a new test to be .... The appropriate sub-image size must be determined in accordance with the ...

  17. Application of digital-image-correlation techniques in analysing ...

    Indian Academy of Sciences (India)

    experimental results obtained using the digital image correlation analysis is used to demonstrate the crack ... The analysis procedure of the DIC method is shown in figure 1. The analysis region is divided .... The observation also proves the accuracy of the qualitative analyses by using the DIC technique. However, fig-.

  18. Subtraction radiography of interradicular bone lesions

    Energy Technology Data Exchange (ETDEWEB)

    Kullendorf, B.; Groendahl, K.; Rohlin, M.; Nilsson, M. (Lund Univ., Malmoe (Sweden))

    1992-10-01

    Subtraction and conventional radiography were evaluated for their diagnostic potential to assess interradicular bone lesions in the mandibular premolar region. Both conventional radiographs and subtraction images were interpreted by 10 observers. The receiver-operating characteristic technique was used to compare the two techniques. The diagnostic validity was higher for the subtraction technique, both for lesions confined to cancellous bone and for lesions including the cortical bone, than for the conventional technique. For bone defects confined to cancellous bone the diagnostic accuracy was lower than those reported from periapical bone lesion irrespective of whether subtraction or conventional radiography was used. It is concluded that subtraction radiography improves the detectability of bone lesions, shallow ones in particular. Lesions in the interradicular bone are more difficult to detect than those in the periapical bone. 26 refs., 3 figs., 2 tabs.

  19. Subtraction radiography of interradicular bone lesions

    International Nuclear Information System (INIS)

    Kullendorf, B.; Groendahl, K.; Rohlin, M.; Nilsson, M.

    1992-01-01

    Subtraction and conventional radiography were evaluated for their diagnostic potential to assess interradicular bone lesions in the mandibular premolar region. Both conventional radiographs and subtraction images were interpreted by 10 observers. The receiver-operating characteristic technique was used to compare the two techniques. The diagnostic validity was higher for the subtraction technique, both for lesions confined to cancellous bone and for lesions including the cortical bone, than for the conventional technique. For bone defects confined to cancellous bone the diagnostic accuracy was lower than those reported from periapical bone lesion irrespective of whether subtraction or conventional radiography was used. It is concluded that subtraction radiography improves the detectability of bone lesions, shallow ones in particular. Lesions in the interradicular bone are more difficult to detect than those in the periapical bone. 26 refs., 3 figs., 2 tabs

  20. Digital signal processing techniques and applications in radar image processing

    CERN Document Server

    Wang, Bu-Chin

    2008-01-01

    A self-contained approach to DSP techniques and applications in radar imagingThe processing of radar images, in general, consists of three major fields: Digital Signal Processing (DSP); antenna and radar operation; and algorithms used to process the radar images. This book brings together material from these different areas to allow readers to gain a thorough understanding of how radar images are processed.The book is divided into three main parts and covers:* DSP principles and signal characteristics in both analog and digital domains, advanced signal sampling, and

  1. Advanced Equalization Techniques for Digital Coherent Optical Receivers

    DEFF Research Database (Denmark)

    Arlunno, Valeria

    employing multiplexing techniques with polarization multiplexing and multi-level modulations format. Advanced digital signal processing techniques offer robustness and flexibility for next generation high capacity optical fibre networks and are therefore considered as key building blocks in next generation......This PhD thesis addresses the design and performance evaluation of advanced Digital Signal Processing (DSP) algorithms for coherent optical fiber transmission systems. The research results presented in this thesis report on transmission of highly spectrally efficient optical communication systems...... format detection. Feedback equalization structure have been investigated in high order modulation formats transmission, when combined with coding techniques, and for closed spaced multiplexing scenario. Highlight results presented in this PhD thesis include evaluation and implementation of a novel...

  2. Clinical and radiological of acute ischemic stroke patients without angiographic occlusion on digital subtraction angiogram. A pooled analysis of case series

    International Nuclear Information System (INIS)

    Shah, Qaisar A.; Memon Zeeshan, Muhammad; Vazquez, Gabriela; Suri, M. Fareed K.; Hussein, Haitham M.; Qureshi, Adnan I.; Mohammad, Yousef M.

    2008-01-01

    Approximately 20-30% of the patients with acute ischemic stroke do not have any occlusion demonstrated on initial digital subtraction angiography (DSA). We sought to determine the risk and rates of cerebral infarction and favorable neurological outcome in this group of acute ischemic stroke patients. Patients were identified from a prospectively maintained stroke database and from literature search of MEDLINE, PubMed, and Cochrane databases. All patients had initial neurological assessment on National Institutes of Health Stroke Scale (NIHSS). Patients then underwent DSA after initial head computed tomography (CT) scans. Follow-up radiological assessment at 24-72 h was performed with CT and magnetic resonance imaging scans. Association of stroke risk factors with clinical and radiological outcomes was estimated. A total of 81 patients was analyzed (mean age 63 years; 28 were women). The median NIHSS score was 8 (range 2-25). None of the patients received either intravenous or intra-arterial thrombolytic. Cerebral infarction was detected in 62 (76%) of the 81 patients. Twenty-four to 48-h NIHSS was available for 51 patients only. Neurological improvement was observed in 22 (43%) of the 51 patients. Favorable outcome ascertained at 3-month follow-up was seen in 48 (59%) of the 81 patients. After adjusting for age, sex, and baseline NIHSS, male patients [odds ratio (OR) 4.5 (1.4-14.3), p value=0.01] and patients with age≥ =65 [OR 4.3 (1.2-16.2), p value=0.03] have a higher risk of cerebral infarcts on the follow-up imaging. Similarly, patients who presented with 10 NIHSS [OR 0.21 (0.08-0.61), p value=0.004]. Ischemic stroke patients without arterial occlusion on DSA have a higher risk of cerebral infarction and disability particularly in men, patients over 65 years of age and with NIHSS≥=10. The cause of infarction may have been arterial obstruction with spontaneous recanalization or small vessel occlusion not visible on DSA

  3. TU-H-CAMPUS-IeP1-04: Combined Organ Dose for Digital Subtraction Angiography and Computed Tomography Using Monte Carlo Simulation

    Energy Technology Data Exchange (ETDEWEB)

    Sakabe, D; Ohno, T; Araki, F; Hashida, M; Funama, Y [Kumamota University, Kumamoto, Kumamoto (Japan)

    2016-06-15

    Purpose: The purpose of this study was to evaluate the combined organ dose of digital subtraction angiography (DSA) and computed tomography (CT) using a Monte Carlo (MC) simulation on the abdominal intervention. Methods: The organ doses for DSA and CT were obtained with MC simulation and actual measurements using fluorescent-glass dosimeters at 7 abdominal portions in an Alderson-Rando phantom. DSA was performed from three directions: posterior anterior (PA), right anterior oblique (RAO), and left anterior oblique (LAO). The organ dose with MC simulation was compared with actual radiation dose measurements. Calculations for the MC simulation were carried out with the GMctdospp (IMPS, Germany) software based on the EGSnrc MC code. Finally, the combined organ dose for DSA and CT was calculated from the MC simulation using the X-ray conditions of a patient with a diagnosis of hepatocellular carcinoma. Results: For DSA from the PA direction, the organ doses for the actual measurements and MC simulation were 2.2 and 2.4 mGy/100 mAs at the liver, respectively, and 3.0 and 3.1 mGy/100 mAs at the spinal cord, while for CT, the organ doses were 15.2 and 15.1 mGy/100 mAs at the liver, and 14.6 and 13.5 mGy/100 mAs at the spinal cord. The maximum difference in organ dose between the actual measurements and the MC simulation was 11.0% of the spleen at PA, 8.2% of the spinal cord at RAO, and 6.1% of left kidney at LAO with DSA and 9.3% of the stomach with CT. The combined organ dose (4 DSAs and 6 CT scans) with the use of actual patient conditions was found to be 197.4 mGy for the liver and 205.1 mGy for the spinal cord. Conclusion: Our method makes it possible to accurately assess the organ dose to patients for abdominal intervention with combined DSA and CT.

  4. Magnetic resonance evaluation of renal artery stenosis in a swine model: performance of low-dose gadobutrol versus gadoterate meglumine in comparison with digital subtraction intra-arterial catheter angiography.

    Science.gov (United States)

    Morelli, John N; Runge, Val M; Ai, Fei; Zhang, Wei; Li, Xiaoming; Schmitt, Peter; McNeal, Gary; Miller, Matthew; Lennox, Mark; Wusten, Oliver; Schoenberg, Stefan O; Attenberger, Ulrike I

    2012-06-01

    The aim of this study was to compare low-dose imaging with gadobutrol and gadoterate meglumine (Gd-DOTA) for evaluation of renal artery stenosis with 3-T magnetic resonance angiography (MRA) in a swine model. A total of 12 experimental animals were evaluated using equivalently dosed gadobutrol and Gd-DOTA for time-resolved and static imaging. For time-resolved imaging, the time-resolved imaging with stochastic trajectories (TWIST) technique (temporal footprint, 4.4 seconds) was used; a dose of 1 mL of gadobutrol was injected at 2 mL/s and a dose of 2 mL of Gd-DOTA was injected at both 2 and 4 mL/s. For a separate static acquisition, doses were doubled. The static scans were used for stenosis gradation and the time-resolved scans for comparison of enhancement dynamics, signal-to-noise ratio (SNR), and qualitative assessments. The average magnitude of difference in the stenosis measurements with static gadobutrol scans relative to digital subtraction intra-arterial catheter angiography (mean [SD], 7.4% [5.6%]) was less than with both the 2 mL/s (10.6% [6.2%]) and 4 mL/s (11.5% [7.8%]) Gd-DOTA MRA protocols. On time-resolved scans, peak signal-to-noise ratio was greatest with the gadobutrol protocol (P < 0.05), and the gadobutrol TWIST scan was preferred to the TWIST Gd-DOTA scan in terms of image quality and stenosis visualization in every case for every reader. Low-dose gadobutrol (~0.05 mmoL/kg) contrast-enhanced MRA results in improved accuracy of renal artery stenosis assessments relative to equivalently dosed Gd-DOTA at 3 T.

  5. Image quality in conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Aichinger, U.; Boehner, C.; Dobritz, M.; Bautz, W.; Saebel, M.

    2000-01-01

    Purpose: Comparison of image quality between conventional film screen system, digital phosphor storage plate mammography in magnification technique and digital mammography in CCD-technique. Materials and Methods: Radiograms of a RMI-mammography phantom were acquired using a conventional film screen system, two digital storage plate systems and two digital systems in CCD-technique. Additionally, the radiograms of one digital phosphor storage plate system were post-processed emphasizing contrast and included in the comparison. Results: The detectability of details was the best with the digital mammography in CCD-technique in comparison with the conventional film screen technique resp. digital phosphor storage plate in magnification technique. Conclusions: Based on these results there is the possibility to replace the conventional film screen system by further studies - this has to be confirmed. (orig.) [de

  6. Carbon dioxide (CO{sub 2}) digital subtraction angiography. Evaluation of a new delivery system; Angiografia con anidride carbonica. Nuovo sistema di iniezione

    Energy Technology Data Exchange (ETDEWEB)

    Nicolini, A.; Lovaria, A.; Meregaglia, D. [Ospedale Maggiore IRCCS Policlinico, Milan (Italy). Dipt. di Scienze Radiologiche; Palatresi, S. [Ospedale Maggiore IRCCS Policlinico, Milan (Italy). Ist. di Clinica Medica Generale e Terapia Medica

    2000-02-01

    Purpose of this work is to evaluate the usefulness of a new carbon dioxide (CO{sub 2}) intravascular injection system in digital subtraction angiography. March 1998 to May 1999, 39 patients were submitted to digital subtraction angiography with CO{sub 2} injection by a new delivery system, CO{sub 2}-Angio set, OptiMed, Ettingen, Germany. The patients were 29 men and 10 women, whose age ranged 32 to 76 (mean: 47), 18 of them with absolute or relative contraindications to iodinated contrast media and 6 with poor diagnostic findings at previous conventional angiography. CO{sub 2} was used for comparison with iodinated contrast agents in 4 patients. It was studied the following vascular districts: renal arteries in 9 patients, portal vein in 18, lower limb arteries in 7, upper limb veins in 4. In 1 patient CO{sub 2} angiography was carried out for the diagnosis and interventional treatment, by transcatheter embolization, of a postbioptic arteriovenous renal fistula. During the procedure, arterial blood pressure, EKG status and oxygen saturation were monitored, and subjective sensations recorded in all patients. CO{sub 2} angiography provided adequate visualization of vascular districts and of abnormal findings in 32 cased (82%), while its results were considered insufficient for correct and complete assessment in 7 cases (18%). CO{sub 2}-Angio set delivery system has proved to be a simple and safe tool, particularly suitable for use in patients at risk for allergic reactions to iodinated contrast agents and in those with renal function impairment. Also, the system can help carry out some interventional procedures such as arteriovenous fistula embolization and trans jugular portosystemic shunting. [Italian] Scopo di questo articolo e' verificare la validita' e l'efficacia di un nuovo sistema di iniezione angiografico per anidride carbonica. Da marzo 1998 a maggio 1999 sono stati sottoposti ad angiografia con anidride carbonica mediante sistema non

  7. The Photoshop Smile Design technique (part 1): digital dental photography.

    Science.gov (United States)

    McLaren, Edward A; Garber, David A; Figueira, Johan

    2013-01-01

    The proliferation of digital photography and imaging devices is enhancing clinicians' ability to visually document patients' intraoral conditions. By understanding the elements of esthetics and learning how to incorporate technology applications into clinical dentistry, clinicians can predictably plan smile design and communicate anticipated results to patients and ceramists alike. This article discusses camera, lens, and flash selection and setup, and how to execute specific types of images using the Adobe Photoshop Smile Design (PSD) technique.

  8. Dual-energy subtraction radiography of the breast

    Energy Technology Data Exchange (ETDEWEB)

    Asaga, Taro; Masuzawa, Chihiro; Kawahara, Satoru; Motohashi, Hisahiko; Okamoto, Takashi; Tamura, Nobuo

    1988-06-01

    Dual-energy projection radiography was applied to breast examination. To perform the dual-energy subtraction radiography using a digital radiography unit, high and low-energy exposures were made at an appropriate time interval under differing X-ray exposure conditions. Dual-energy subtraction radiography was performed in 41 cancer patients in whom the tumor shadow was equivocal or the border of cancer infiltration was not clearly demonstrated by compression mammography, and 15 patients with benign diseases such as fibrocystic disease, cyst and fibroadenoma. In 21 cases out of the 41 cancer patients, the dual-energy subtraction radiography clearly visualized the malignant tumor shadows and the border of cancer infiltration and the daughter nodules by removing the shadows of normal mammary gland. On the other hand, beign diseases such as fibrocystic disease and cyst could be diagnosed as such, because the tumor shadow and the irregularly concentrated image of mammary gland disappeared by the dual-energy subtraction. These results suggest that this new technique will be useful in examination of breast masses.

  9. Monitoring of civil engineering structures using Digital Image Correlation technique

    Directory of Open Access Journals (Sweden)

    Świercz A.

    2010-06-01

    Full Text Available The Digital Image Correlation (DIC technique enables full field, noncontact measurements of displacements and strains of a wide variety of objects. An adaptation of the DIC technique for monitoring of civil-engineering structures is presented in the paper. A general concept of the complex, automatic monitoring system, in which the DIC sensor plays an important role is described. Some new software features, which aim to facilitate outdoor measurements and speed up the correlation analysis, is also introduced. As an example of application, measurements of a railway bridge in Nieporet (Poland are presented. The experimental results are compared with displacements of a FEM model of the bridge.

  10. Application of the PRBS/FFT technique to digital simulations

    International Nuclear Information System (INIS)

    Hinds, H.W.

    1977-01-01

    This paper describes a method for obtaining a small-signal frequency response from a digital dynamic simulation. It employs a modified form of the PRBS/FFT technique, whereby a system is perturbed by a pseudo-random binary sequence and its response is analyzed using a fast Fourier transform-based program. Two applications of the technique are described; one involves a set of two coupled, second-order, ordinary differential equations; the other is a set of non-linear partial differential equations describing the thermohydraulic behaviour of water boiling in a fuel channel. (author)

  11. Application of digital imaging techniques to flare monitoring

    International Nuclear Information System (INIS)

    Rodrigues, Shaun J; Yan, Yong

    2011-01-01

    This paper presents a technique for detecting and monitoring flares in harsh industrial environments with the use of an imaging sensor combined with digital image processing. Flare images are captured via an imaging fibre and analysed to detect the flare's presence and region of interest. The flare characteristics are then determined using various image processing algorithms. A prototype system is designed, constructed and evaluated on a purpose built laboratory scale flare test rig. Results indicate that the imaging based technique has potential for the detection, monitoring and analysis of flares amidst various background conditions in the chemical and oil industries for plant safety, pollution prevention and control.

  12. Optimization of background subtraction for image enhancement

    Science.gov (United States)

    Venetsky, Larry; Boczar, Ross; Lee-Own, Robert

    2013-05-01

    Analysis of foreground objects in scenery via image processing often involves a background subtraction process. This process aims to improve blob (connected component) content in the image. Quality blob content is often needed for defining regions of interest for object recognition and tracking. Three techniques are examined which optimize the background to be subtracted - genetic algorithm, an analytic solution based on convex optimization, and a related application of the CVX solver toolbox. These techniques are applied to a set of images and the results are compared. Additionally, a possible implementation architecture that uses multiple optimization techniques with subsequent arbitration to produce the best background subtraction is considered.

  13. Iterative and noniterative nonuniform quantisation techniques in digital holography

    Science.gov (United States)

    Shortt, Alison E.; Naughton, Thomas J.; Javidi, Bahram

    2006-04-01

    Compression is essential for efficient storage and transmission of three-dimensional (3D) digital holograms. The inherent speckle content in holographic data causes lossless compression techniques, such as Huffman and Burrows-Wheeler (BW), to perform poorly. Therefore, the combination of lossy quantisation followed by lossless compression is essential for effective compression of digital holograms. Our complex-valued digital holograms of 3D real-world objects were captured using phase-shift interferometry (PSI). Quantisation reduces the number of different real and imaginary values required to describe each hologram. Traditional data compression techniques can then be applied to the hologram to actually reduce its size. Since our data has a nonuniform distribution, the uniform quantisation technique does not perform optimally. We require nonuniform quantisation, since in a histogram representation our data is denser around the origin (low amplitudes), thus requiring more cluster centres, and sparser away from the origin (high amplitudes). By nonuniformly positioning the cluster centres to match the fact that there is a higher probability that the pixel will have a low amplitude value, the cluster centres can be used more efficiently. Nonuniform quantisation results in cluster centres that are adapted to the exact statistics of the input data. We analyse a number of iterative (k-means clustering, Kohonen competitive neural network, SOM, and annealed Hopfield neural network), and non-iterative (companding, histogram, and optimal) nonuniform quantisation techniques. We discuss the strengths and weaknesses of each technique and highlight important factors that must be considered when choosing between iterative and non-iterative nonuniform quantisation. We measure the degradation due to lossy quantisation in the reconstruction domain, using the normalised rms (NRMS) metric.

  14. Optimization of digital radiography techniques for specific application

    International Nuclear Information System (INIS)

    Harara, W.

    2010-12-01

    A low cost digital radiography system (DRS) for testing weld joints and castings in laboratory was assembled. The DRS is composed from X-ray source, scintillator, first surface mirror with Aluminum coating, charged coupled device (CCD) camera and lens. The DRS was used to test flawed carbon steel welded plates with thicknesses up to 12 mm. The comparison between the digital radiographs of the plates weldments and the radiographs of the same plates weldments using medium speed film type had shown that, the detection capability of the weld flaws are nearly identical for the two radiography techniques, while the sensitivity achieved in digital radiography of the plates weldments was one IQI wire less than the sensitivity achieved by conventional radiography of the same plates weldments according to EN 462-1. Further, the DRS was also successfully used to test (100 x 100 x 100) mm Aluminum casting with artificial flaws of varied dimensions and orientations. The resulted digital radiographs of the casting show that, all the flaws had been detected and their dimensions can be measured accurately, this confirm that, The proposed DRS can be used to detect and measure the flaws in the Aluminum and others light metals castings accurately. (author)

  15. Digital mammography: state of the art.

    Science.gov (United States)

    Gater, Laura

    2002-01-01

    After completing this update on digital mammography, readers will: Understand some limitations of film-screen mammography. Know the potential advantages and disadvantages of digital mammography. Compare and contrast some different digital mammography systems. Describe how digital images are captured, processed, displayed and stored. Know how digital mammography affects radiation dose, exposure time and contrast resolution. Understand how digital images are transmitted. Be familiar with new techniques that build on digital mammography, such as 3-D mammography, digital subtraction mammography and computer-aided detection.

  16. Digital data over video channels - Techniques for Spacelab

    Science.gov (United States)

    Smith, Dean L.; Hanby, Walter D.

    1993-01-01

    A study was made of various techniques for transmitting digital data over a composite video channel. Transmitting data from experiments on the Space Shuttle Orbiter over a video channel is attractive since extra channel capacity is needed. Broadcast television telecommunications schemes and other techniques described in the literature were reviewed and compared. PSK (Phase Shift Keying), MPSK (m-ary PSK), or PAM (Pulse Amplitude Modulation) can be transmitted on visible lines of a frame, unassigned lines of the VBI (Vertical Blanking Interval), or during the HBI (Horizontal Blanking Interval). All three modulation techniques can be attractive under the proper conditions. However, PAM on visible lines or during the VBI should be relatively easy to implement, provide adequate average data rates, and give acceptable BERs (Bit Error Rates).

  17. Digital prototyping technique applied for redesigning plastic products

    Science.gov (United States)

    Pop, A.; Andrei, A.

    2015-11-01

    After products are on the market for some time, they often need to be redesigned to meet new market requirements. New products are generally derived from similar but outdated products. Redesigning a product is an important part of the production and development process. The purpose of this paper is to show that using modern technology, like Digital Prototyping in industry is an effective way to produce new products. This paper tries to demonstrate and highlight the effectiveness of the concept of Digital Prototyping, both to reduce the design time of a new product, but also the costs required for implementing this step. The results of this paper show that using Digital Prototyping techniques in designing a new product from an existing one available on the market mould offers a significantly manufacturing time and cost reduction. The ability to simulate and test a new product with modern CAD-CAM programs in all aspects of production (designing of the 3D model, simulation of the structural resistance, analysis of the injection process and beautification) offers a helpful tool for engineers. The whole process can be realised by one skilled engineer very fast and effective.

  18. Technique for evaluation of spatial resolution and microcalcifications in digital and scanned images of a standard breast phantom

    International Nuclear Information System (INIS)

    Santana, Priscila do C.; Gomes, Danielle S.; Oliveira, Marcio A.; Oliveira, Paulo Marcio C. de; Meira-Belo, Luiz C.; Nogueira-Tavares, Maria S.

    2011-01-01

    In this work, an automated methodology to evaluate digital and scanned images of a standard phantom (Phantom Mama) was studied. The Phantom Mama was used as an important tool to check the quality of mammographs. The scanned images were digitized using a ScanMaker 9800XL, with resolution of 900 dpi. The aim of this work is to test an automatic methodology for evaluation of spatial resolution and microcalcifications group of phantom mama images acquired with the same parameters in the same equipment. In order to analyze the images we have used the ImageJ software (in Java) which is public domain. We have used the Fast Fourier transform technique to evaluate the spatial resolution and used the ImageJ function Subtract Background and the Light Background plus Sliding Paraboloid on the evaluation of the five groups of microcalcifications on the breast phantom to assess the viability of using automated methods for both types of images. The methodology was adequate for evaluated the microcalcifications group and the spatial resolution in scanned and digital images, but the Phantom Mama doesn't provide sufficient parameters to evaluate the spatial resolution in this images. (author)

  19. Digital Image Processing Technique for Breast Cancer Detection

    Science.gov (United States)

    Guzmán-Cabrera, R.; Guzmán-Sepúlveda, J. R.; Torres-Cisneros, M.; May-Arrioja, D. A.; Ruiz-Pinales, J.; Ibarra-Manzano, O. G.; Aviña-Cervantes, G.; Parada, A. González

    2013-09-01

    Breast cancer is the most common cause of death in women and the second leading cause of cancer deaths worldwide. Primary prevention in the early stages of the disease becomes complex as the causes remain almost unknown. However, some typical signatures of this disease, such as masses and microcalcifications appearing on mammograms, can be used to improve early diagnostic techniques, which is critical for women’s quality of life. X-ray mammography is the main test used for screening and early diagnosis, and its analysis and processing are the keys to improving breast cancer prognosis. As masses and benign glandular tissue typically appear with low contrast and often very blurred, several computer-aided diagnosis schemes have been developed to support radiologists and internists in their diagnosis. In this article, an approach is proposed to effectively analyze digital mammograms based on texture segmentation for the detection of early stage tumors. The proposed algorithm was tested over several images taken from the digital database for screening mammography for cancer research and diagnosis, and it was found to be absolutely suitable to distinguish masses and microcalcifications from the background tissue using morphological operators and then extract them through machine learning techniques and a clustering algorithm for intensity-based segmentation.

  20. Digital arteriography of kidney arteries by intraveinous route. Simplified technique

    International Nuclear Information System (INIS)

    Guisgand, M.; Dardenne, A.N.

    1989-01-01

    Of the 1,000 patients addressed to us for intravenous digital angiography (IVDA) of the renal arteries for arterial hypertension, for control of the artery of a transplanted kidney or for preoperative check-up prior to transplantation of a kidney, 738 were examined by a simplified technique. Compared to the standard practice this method simply consists of a manual injection of a standard ionic contrast medium via an antecubital vein punctured with a large catheter needle (caliber 14 G), without preparatory injection of an intestinal antispasmodic. This method has produced a satisfactory arterial opacification in 96 % of the cases. The advantages and disadvantages of the technique are discussed. Of the 262 remaining patients, 250 were also examined by the peripheral venous mode, but the technique had to be modified in at least one of its aspects for one reason or another. Only 12 patients were not examined by the peripheral venous mode (7 puncture failures, 4 permanent venous accesses already installed). The IVDA simplified technique appears to be reliable for detecting reno-vascular arterial hyper-tension and, with certain limitations, for the control of kidney grafts. With regard to the preoperative check-up before kidney transplantation, IVDA still does not seem a suitable replacement for the traditional method of angiography [fr

  1. Radionuclide identification using subtractive clustering method

    Energy Technology Data Exchange (ETDEWEB)

    Farias, Marcos Santana, E-mail: msantana@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Div. de Instrumentacao e Confiabilidade Humana; Nedjah, Nadia, E-mail: nadia@eng.uerj.br [Departamento de Engenharia Eletronica e Telecomunicacoes. Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil); Mourelle, Luiza de Macedo, E-mail: ldmm@eng.uerj.br [Departamento de Engenharia de Sistemas e Computacao. Universidade do Estado do Rio de Janeiro (UERJ), RJ (Brazil)

    2011-07-01

    Radionuclide identification is crucial to planning protective measures in emergency situations. This paper presents the application of a method for a classification system of radioactive elements with a fast and efficient response. To achieve this goal is proposed the application of subtractive clustering algorithm. The proposed application can be implemented in reconfigurable hardware, a flexible medium to implement digital hardware circuits. (author)

  2. Radionuclide identification using subtractive clustering method

    International Nuclear Information System (INIS)

    Farias, Marcos Santana; Mourelle, Luiza de Macedo

    2011-01-01

    Radionuclide identification is crucial to planning protective measures in emergency situations. This paper presents the application of a method for a classification system of radioactive elements with a fast and efficient response. To achieve this goal is proposed the application of subtractive clustering algorithm. The proposed application can be implemented in reconfigurable hardware, a flexible medium to implement digital hardware circuits. (author)

  3. Analogue to Digital and Digital to Analogue (AD/DA) Conversion Techniques: An Overview

    CERN Multimedia

    CERN. Geneva

    2002-01-01

    The basic ideas behind modern Analogue to Digital and Digital to Analogue (AD/DA) conversion methods will be introduced: a general view of the importance of these devices will be given, along with the digital representation of time-varying, real-world analogue signals. Some CERN applications will be outlined. The variety of conversion methods, their limitations, error sources and measurement methods will form the major part of this presentation. A review of the technological progress in this field over the last 30 years will be presented, concluding with the present 'state of the art' and a quick look at what is just around the corner. This Technical Training Seminar is in the framework of the FEED-2002 Lecture Series, and it is a prerequisite to attending to any of the FEED-2002 Terms. FEED-2002 is a two-term course that will review the techniques dealing with closed loop systems, focussing on time-invariant linear systems. (free attendance, no registration required) More information on the FEED-2002 ...

  4. Real-time digital angiocardiography using a temporal high-pass filter

    International Nuclear Information System (INIS)

    Hardin, C.W.; Kruger, R.A.; Anderson, F.L.; Bray, B.F.; Nelson, J.A.

    1984-01-01

    A temporal high-pass filtration technique for digital subtraction angiocardiography was studied, using real-time digital studies performed simultaneously with routine cineangiocardiography (cine) for qualitative image comparison. The digital studies showed increased contrast and suppression of background anatomy and also enhanced detection of wall motion abnormalities when compared with cine. The digital images are comparable with, and in some cases better than, cine images. Clinical efficacy of this digital technique is currently being evaluated

  5. Optimization of Technique Factors for full-Field Digital Mammography and Comparison of Optimized Techniques to Screen-Film Mammography

    National Research Council Canada - National Science Library

    Berns, Eric

    2002-01-01

    The technical objectives of this study are to determine optimum techniques for a flat-panel Cesium- iodide silicon-diode full-field digital mammography system and to compare those optimized techniques...

  6. Optimization of Technique Factors for Full-Field Digital Mammography and Comparison of Optimized Techniques to Screen-Film Mammography

    National Research Council Canada - National Science Library

    Berns, Eric

    2001-01-01

    The technical objectives of this study are to determine optimum techniques for a flat-panel Cesium-iodide silicon-diode full-field digital mammography system and to compare those optimized techniques...

  7. High kilovoltage digital exposure techniques and patient dosimetry.

    Science.gov (United States)

    Fauber, Terri L; Cohen, Timmerie F; Dempsey, Melanie C

    2011-01-01

    To explore digital exposure techniques during pelvic imaging on patient dosimetry, exposure indicator (EXI) values and image quality. An experimental design was used to study the effect of varying kilovoltage peak (kVp) and milliampere-seconds (mAs) on a male phantom pelvis when using a direct digital radiography (DR) flat panel detector. The radiation intensity was varied by increasing the kVp and reducing mAs. Image quality was evaluated by assessing density, density differences, quantum noise and overall diagnostic quality. When the kVp was increased in 15% increments and mAs divided by half, the radiation dose to the gonads significantly decreased. The lowest and highest kVp exposure groups produced the lowest EXI values. There was no correlation between the thermoluminescent dosimeter milliroentgen (mR) measurements and the EXI values. The results indicate that a pelvic DR image produced at 93 kVp and 12.5 mAs will reduce the gonadal dose while maintaining an image of diagnostic quality.

  8. Study of a new scatter rejection technique in digital radiography

    International Nuclear Information System (INIS)

    Bottari, S.; Ciocci, M.A.; Fortunato, M.; Maestro, P.; Malakhov, N.; Marrocchesi, P.S.; Meucci, M.; Millucci, V.; Paoletti, R.; Scribano, A.; Turini, N.

    2001-01-01

    A new technique for digital mammography based on the use of a collimator and an anti-scatter grid coupled with a mosaic detector has been studied with a Monte Carlo program. The simulation, with a low-energy spectrum X-ray beam and a breast phantom, provides a quantitative assessment of the capability of the method to reduce the physical background of the image due to scattering in the body, without introducing image artifacts. With minor modifications to the existing X-ray facilities, the method could also be applied to area detectors. To verify the results of the simulation, an experimental setup based on a CCD camera coupled via a fiber optic plate to a CsI(Tl) scintillator is under test

  9. Study of a new scatter rejection technique in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bottari, S.; Ciocci, M.A. E-mail: ciocci@pi.infn.it; Fortunato, M.; Maestro, P.; Malakhov, N.; Marrocchesi, P.S.; Meucci, M.; Millucci, V.; Paoletti, R.; Scribano, A.; Turini, N

    2001-04-01

    A new technique for digital mammography based on the use of a collimator and an anti-scatter grid coupled with a mosaic detector has been studied with a Monte Carlo program. The simulation, with a low-energy spectrum X-ray beam and a breast phantom, provides a quantitative assessment of the capability of the method to reduce the physical background of the image due to scattering in the body, without introducing image artifacts. With minor modifications to the existing X-ray facilities, the method could also be applied to area detectors. To verify the results of the simulation, an experimental setup based on a CCD camera coupled via a fiber optic plate to a CsI(Tl) scintillator is under test.

  10. Comparison between two non-contact techniques for art digitalization

    Science.gov (United States)

    Bianconi, F.; Catalucci, S.; Filippucci, M.; Marsili, R.; Moretti, M.; Rossi, G.; Speranzini, E.

    2017-08-01

    Many measurements techniques have been proposed for the “digitalization of objects”: structured light 3D scanner, laser scanner, high resolution camera, depth cam, thermal-cam, … Since the adoption of the European Agenda for Culture in 2007, heritage has been a priority for the Council’s work plans for culture, and cooperation at European level has advanced through the Open Method of Coordination. Political interest at EU level has steadily grown cultural and heritage stakeholders recently highlighted in the Declaration on a New Narrative for Europe: “Europe as a political body needs to recognize the value of Cultural Heritage”. Photomodelling is an innovative and extremely economical technique related to the conservation of Cultural Heritage, which leads to the creation of three-dimensional models starting from simple photographs. The aim of the research is to understand the full potential offered by this new technique and dedicated software, analysing the reliability of each instrument, with particular attention to freeware ones. An analytical comparison between photomodelling and structured light 3D scanner guarantees a first measure of the reliability of instruments, tested in the survey of several Umbrian heritage artefacts. The comparison between tests and reference models is explained using different algorithms and criteria, spatial, volumetric and superficial.

  11. DIGITAL SURVEY TECHNIQUES FOR THE DOCUMENTATION OF WOODEN SHIPWRECKS

    Directory of Open Access Journals (Sweden)

    E. Costa

    2016-06-01

    Full Text Available Nowadays, researchers widely employ the acquisition of point clouds as one of the principal type of documentation for cultural heritage. In this paper, different digital survey techniques are employed to document a wooden ancient shipwreck, a particular and difficult kind of archaeological finding due to its material characteristics. The instability of wood and the high costs of restoration do not always offer the opportunity of recovering and showing the hull to researchers and public and three-dimensional surveys are fundamental to document the original conditions of the wood. The precarious conditions of this material in contact with air could modify the structure and the size of the boat, requiring a fast and accurate recording technique. The collaboration between Ca' Foscari University and the Laboratory of Photogrammetry of Iuav University of Venice has given the possibility to demonstrate the utility of these technology. We have surveyed a sewn boat of Roman age through multi-image photogrammetry and laser scanner. Point clouds were compared and a residual analysis was done, to verify the characteristics and the opportunity of the two techniques, both of them have allowed obtaining a very precise documentation from a metrical point of view.

  12. Blind I/Q imbalance compensation technique for direct-conversion digital radio transceivers

    CSIR Research Space (South Africa)

    De

    2009-05-01

    Full Text Available . Digital signal processing techniques have widely been proposed to compensate for these mixer imperfections. Of these techniques, the class of blind compensation techniques seems very attractive since no test signals are required. This paper presents a...

  13. Added Value of Bone Subtraction in Dual-energy Digital Radiography in the Detection of Pneumothorax: Impact of Reader Expertise and Medical Specialty.

    Science.gov (United States)

    Urbaneja, Ayla; Dodin, Gauthier; Hossu, Gabriela; Bakour, Omar; Kechidi, Rachid; Gondim Teixeira, Pedro; Blum, Alain

    2018-01-01

    This study aimed to determine the value of dual-energy thoracic radiography in the diagnosis of pneumothorax considering the reader's experience. Forty patients with a suspected pneumothorax, imaged with dual-energy chest radiographs, were divided into two groups: those with pneumothorax as the final diagnosis (n = 19) and those without (n = 21). The images were analyzed by 36 readers (5 interns, 16 residents, 15 senior physicians) for the presence or absence of pneumothorax during three readout sessions at 2-week intervals: standard images alone (session 1), dual-energy images with bone subtraction alone (session 2), and a combination of the two (session 3). The number of correct responses increased 13.3% between sessions 1 and 2 (P expertise. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  14. A digital technique for linearising the output of a turbine anemometer.

    Science.gov (United States)

    Crane, R A; Stuttard, B

    1976-01-01

    A technique is described by which it is possible, using digital integrated circuits, to linearise the output of transducers which produce their output in serial digital form. The linearisation technique is used to improve the performance of an anemometer used in the measurement of pulmonary function. The new technique makes possible accurate paediatric measurements using transducers previously intended for adults.

  15. Chip-by-chip configurable interconnection using digital printing techniques

    International Nuclear Information System (INIS)

    Mashayekhi, Mohammad; Carrabina, Jordi; Winchester, Lee; Laurila, Mika-Matti; Mäntysalo, Matti; Ogier, Simon; Terés, Lluís

    2017-01-01

    Printed electronics technologies add new fabrication concepts to the classical set of microelectronic processes. Among these, the use of digital printing techniques such as inkjet permits the deposition of materials on top of preexisting substrates without any mask. This allows individual personalization of electronic circuits. Different proposals have been made to make use of such a property: (1) wiring new metallic layers on top of circuits to build programmable logic array-like circuits, (2) programming OTP ROM like memories, and (3) building inkjet-configurable gate arrays. The capability of building an individual circuit with technological steps simpler than photolithographic ones opens a concept similar to the successful field programmable gate array. Although nowadays the process resolution is still low, it can quickly evolve to higher wiring densities and therefore permit a greater level of transistor integration. In this paper, we propose a new structure to realize the connections only by deposition of conductive dots oriented to optimize the area needed to implement the drop-on-demand (DoD) wiring at circuit level. One important feature of this structure is that it minimizes the amount of printed material required for the connection thereby reducing failures often seen with DoD printing techniques for conductive lines. These structures have been validated by two different DoD technologies: inkjet and superfine jet, and have been compared to mask-based photolithography technology with promising results. (paper)

  16. Chip-by-chip configurable interconnection using digital printing techniques

    Science.gov (United States)

    Mashayekhi, Mohammad; Winchester, Lee; Laurila, Mika-Matti; Mäntysalo, Matti; Ogier, Simon; Terés, Lluís; Carrabina, Jordi

    2017-04-01

    Printed electronics technologies add new fabrication concepts to the classical set of microelectronic processes. Among these, the use of digital printing techniques such as inkjet permits the deposition of materials on top of preexisting substrates without any mask. This allows individual personalization of electronic circuits. Different proposals have been made to make use of such a property: (1) wiring new metallic layers on top of circuits to build programmable logic array-like circuits, (2) programming OTP ROM like memories, and (3) building inkjet-configurable gate arrays. The capability of building an individual circuit with technological steps simpler than photolithographic ones opens a concept similar to the successful field programmable gate array. Although nowadays the process resolution is still low, it can quickly evolve to higher wiring densities and therefore permit a greater level of transistor integration. In this paper, we propose a new structure to realize the connections only by deposition of conductive dots oriented to optimize the area needed to implement the drop-on-demand (DoD) wiring at circuit level. One important feature of this structure is that it minimizes the amount of printed material required for the connection thereby reducing failures often seen with DoD printing techniques for conductive lines. These structures have been validated by two different DoD technologies: inkjet and superfine jet, and have been compared to mask-based photolithography technology with promising results.

  17. Digital Sculpting with Mudbox Essential Tools and Techniques for Artists

    CERN Document Server

    de la Flor, Mike

    2010-01-01

    Digital sculpting is the use of tools to push, pull, smooth, grab, pinch or otherwise manipulate a digital object as if it were made of a real-life substance such as clay. Mudbox is the premier sculpting solution for digital artists, allowing them to naturally and easily sculpt detailed, organic characters and models in a way that feels like traditional sculpting.This book guides CG professionals through the process of creating amazing digital sculptures using the Mudbox arsenal of ground-breaking digital sculpting and 3D painting tools, and porting the models into their Maya or Max work.Artis

  18. Digital fluoroscopy: a new development in medical imaging

    International Nuclear Information System (INIS)

    Maher, K.P.; Malone, J.F.; Dublin Inst. of Technology

    1986-01-01

    Medical fluoroscopy is briefly reviewed and video-image digitization is described. Image processing requirements and image processors available for digital fluoroscopy are discussed in detail. Specific reference is made to an application of digital fluoroscopy in the imaging of blood-vessels. This application involves an image substraction technique which is referred to as digital subtraction angiography (DSA). A number of DSA images of relevance to the discussion are included. (author)

  19. Automated Coronal Loop Identification Using Digital Image Processing Techniques

    Science.gov (United States)

    Lee, Jong K.; Gary, G. Allen; Newman, Timothy S.

    2003-01-01

    The results of a master thesis project on a study of computer algorithms for automatic identification of optical-thin, 3-dimensional solar coronal loop centers from extreme ultraviolet and X-ray 2-dimensional images will be presented. These center splines are proxies of associated magnetic field lines. The project is pattern recognition problems in which there are no unique shapes or edges and in which photon and detector noise heavily influence the images. The study explores extraction techniques using: (1) linear feature recognition of local patterns (related to the inertia-tensor concept), (2) parametric space via the Hough transform, and (3) topological adaptive contours (snakes) that constrains curvature and continuity as possible candidates for digital loop detection schemes. We have developed synthesized images for the coronal loops to test the various loop identification algorithms. Since the topology of these solar features is dominated by the magnetic field structure, a first-order magnetic field approximation using multiple dipoles provides a priori information in the identification process. Results from both synthesized and solar images will be presented.

  20. Applying advanced digital signal processing techniques in industrial radioisotopes applications

    International Nuclear Information System (INIS)

    Mahmoud, H.K.A.E.

    2012-01-01

    Radioisotopes can be used to obtain signals or images in order to recognize the information inside the industrial systems. The main problems of using these techniques are the difficulty of identification of the obtained signals or images and the requirement of skilled experts for the interpretation process of the output data of these applications. Now, the interpretation of the output data from these applications is performed mainly manually, depending heavily on the skills and the experience of trained operators. This process is time consuming and the results typically suffer from inconsistency and errors. The objective of the thesis is to apply the advanced digital signal processing techniques for improving the treatment and the interpretation of the output data from the different Industrial Radioisotopes Applications (IRA). This thesis focuses on two IRA; the Residence Time Distribution (RTD) measurement and the defect inspection of welded pipes using a gamma source (gamma radiography). In RTD measurement application, this thesis presents methods for signal pre-processing and modeling of the RTD signals. Simulation results have been presented for two case studies. The first case study is a laboratory experiment for measuring the RTD in a water flow rig. The second case study is an experiment for measuring the RTD in a phosphate production unit. The thesis proposes an approach for RTD signal identification in the presence of noise. In this approach, after signal processing, the Mel Frequency Cepstral Coefficients (MFCCs) and polynomial coefficients are extracted from the processed signal or from one of its transforms. The Discrete Wavelet Transform (DWT), Discrete Cosine Transform (DCT), and Discrete Sine Transform (DST) have been tested and compared for efficient feature extraction. Neural networks have been used for matching of the extracted features. Furthermore, the Power Density Spectrum (PDS) of the RTD signal has been also used instead of the discrete

  1. Digital instantaneous frequency measurement technique utilising high-speed ADC’s and FPGA’s

    CSIR Research Space (South Africa)

    Herselman, PL

    2006-02-27

    Full Text Available of the system are scalable. The theoretical background and derivation of the technique, followed by the practical implementation of the technique on modern digital signal processing hardware, are presented. The paper concludes with functional hardware...

  2. Digital Signal Processing Techniques for the GIFTS SM EDU

    Science.gov (United States)

    Tian, Jialin; Reisse, Robert A.; Gazarik, Michael J.

    2007-01-01

    The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument employs three Focal Plane Arrays (FPAs), which gather measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes several digital signal processing (DSP) techniques involved in the development of the calibration model. In the first stage, the measured raw interferograms must undergo a series of processing steps that include filtering, decimation, and detector nonlinearity correction. The digital filtering is achieved by employing a linear-phase even-length FIR complex filter that is designed based on the optimum equiripple criteria. Next, the detector nonlinearity effect is compensated for using a set of pre-determined detector response characteristics. In the next stage, a phase correction algorithm is applied to the decimated interferograms. This is accomplished by first estimating the phase function from the spectral phase response of the windowed interferogram, and then correcting the entire interferogram based on the estimated phase function. In the calibration stage, we first compute the spectral responsivity based on the previous results and the ideal Planck blackbody spectra at the given temperatures, from which, the calibrated ambient blackbody (ABB), hot blackbody (HBB), and scene spectra can be obtained. In the post-calibration stage, we estimate the Noise Equivalent Spectral Radiance (NESR) from the calibrated ABB and HBB spectra. The NESR is generally considered as a measure of the instrument noise performance, and can be estimated as

  3. Cyber Science, Biometrics and Digital Forensics: Workshop on Emerging Cyber Techniques and Technologies

    Science.gov (United States)

    2016-09-07

    journals : Final Report Proceedings: Cyber Science, Biometrics and Digital Forensics: Workshop on Emerging Cyber Techniques and Technologies Report...and Digital Forensics. Through this one-day workshop, over fifteen feature presentations were made and the group held two Panels to discuss...09-2016 10-Jul-2015 9-Jul-2016 Final Report Proceedings: Cyber Science, Biometrics and Digital Forensics: Workshop on Emerging Cyber Techniques and

  4. REAL TIME MICRODISPLACEMENTS TESTING BY OPTO-DIGITAL HOLOGRAPHIC INTERFEROMETRY TECHNIQUE

    Directory of Open Access Journals (Sweden)

    L BOUAMAMA

    2007-12-01

    Since all the process is controlled numerically, it is possible to follow in real time using the holographic interferometry techniques, double exposure, real time or time average, any changes in the object under study and to start and stop the process at any time by adequate software. This can be done by subtracting a reference image by suitable software directly on the CCD camera. We show also, the ability of the technique to study in real time all evolutional phenomena.

  5. Digital radiographic techniques in the analysis of paintings

    International Nuclear Information System (INIS)

    James, A.E. Jr.; Gibbs, S.J.; James, A.E. III; Pickens, D.R.; Sloan, M.; Price, R.R.; Erickson, J.J.

    1985-01-01

    In this chapter the authors use the term digital radiography to mean any method of radiographic image production in which the silver halide-based film is replaced by an electronic sensor for production of an image. There are essentially three types of digital radiographic systems available at present, but others will be developed. These differ primarily in the method of image production and the rapidity with which images can be produced. The three methods discussed are digital fluoroscopy, scanned projection radiography, and the scanned point source radiography. Each has certain characteristics which, if properly utilized, will allow improved x-ray analysis of paintings

  6. Prototype system for the digital technique based nuclear spectroscopy

    International Nuclear Information System (INIS)

    Bhale, Devendra; Roy, Amitava

    2010-01-01

    A system consisting of FPGA based digital processing hardware and fast sampling by ADC is reported here. At the heart of the system is a Spartan 2 FPGA. The data is converted in digital domain by 4 MSPS ADC. It is interfaced to computer via CAMAC general purpose IO module. Trigger is accepted from external system for event marking. Input exponential pulse is processed by a CR-RC digital filter implemented in FPGA. Trigger dependant peak detection for radiation energy measurement is done on filtered data. Histogram is generated in the PC by using nuclear DAQ software developed in house. (author)

  7. Digital radiology and ultrasound

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.

    1991-01-01

    With the access to digital methods for handling and processing images in general, many medical imaging methods are becoming more effectively handled digitally. This applies in particular to basically digital techniques such as CT and MR but also now includes Nuclear Medicine (NM), Ultrasound (US) and a variety of radiological procedures such as Digital Subtraction Angiography (DSA) and Fluoroscopy (DF). The access to conventional projection images by stimulatable plates (CR) or by digitization of film makes all of radiology potentially accessible, and the management of such images by a network is the basic aim of Picture Archiving and Communication Systems (PACS). However, it is suggested that in order for such systems to be of greater value, that way in which such images are treated needs to change, that is, digital images can be used to derive additional clinical value by appropriate processing

  8. Automatic digital document processing and management problems, algorithms and techniques

    CERN Document Server

    Ferilli, Stefano

    2011-01-01

    This text reviews the issues involved in handling and processing digital documents. Examining the full range of a document's lifetime, this book covers acquisition, representation, security, pre-processing, layout analysis, understanding, analysis of single components, information extraction, filing, indexing and retrieval. This title: provides a list of acronyms and a glossary of technical terms; contains appendices covering key concepts in machine learning, and providing a case study on building an intelligent system for digital document and library management; discusses issues of security,

  9. Digital and conventional radiology techniques: comparison of dosage and costs

    International Nuclear Information System (INIS)

    Arranza, L.; Albornoz, C. de

    1996-01-01

    To compare the radiation dosage and costs in conventional and digital technologies. The study dealt with transverse sections. The dosage applied with conventional technology was measured in 254 patients who intertwined 402 explorations of 6 anatomic regions in 4 Radiodiagnostic Services. The dosage applied with digital technology was measured in 57 patients who underwent 95 explorations of the same anatomic region in one Radiodiagnostic Service. The costs of the 6 types of conventional and digital explorations performed were calculated for two Radiodiagnostic Service. The doses administered (mGy) using convectional/digital technology were as follows: chest PA 0.2/0.1; chest LAT 0.7/0.3; breast CC 7.0/8.4; breast LAT 7.0/7.8; breast OB 7.0/10.5; cervical spine AP 9.6/9.0; cervical spine LAT 21.9/29.6; pelvis AP 7.3/7.1; plain abdominal 6.5/2.2. The costs incurred (1992 pesetas) with the convectional/digital technologies: chest AP and LAT 1,393/2,973; portable chest 2,027/3,714; mammography 2,357/3,486; phlebography 12,718/14,023; hysterosalpingography 4,876/6,701; bone scientigraphy 1,633/2,839. Compared with conventional technology, digital imaging reduces the radiation doses received by the patients, except in the case of mammography. The costs associated with the use of digital technology are greater than those incurred with conventional technology, mainly due to the costs of amortization. the use of digital technology is more justified when: 1) it is very necessary to reduce the dosage; 2) studies of chest and abdomen predominant; 3) the volume of utilization is high; 4) staff management is flexible , and 5) the cost of purchasing the equipment is lower. (Author) 10 refs

  10. Entropy-Based Dark Frame Subtraction

    OpenAIRE

    Goesele, Michael; Heidrich, Wolfgang; Seidel, Hans-Peter

    2001-01-01

    Noise due to dark current is a serious limitation for taking long exposure time images with a CCD digital camera. Current solutions have serious drawbacks: interpolation of pixels with high dark current leads to smoothing effects or other artifacts -- especially if a large number of pixels are corrupted. Due to the exponential temperature dependence of the dark current, dark frame subtraction works best for temperature controlled high end CCD imaging systems. On the ...

  11. Analysis of pulse-shape discrimination techniques for BC501A using GHz digital signal processing

    International Nuclear Information System (INIS)

    Rooney, B.D.; Dinwiddie, D.R.; Nelson, M.A.; Rawool-Sullivan, Mohini W.

    2001-01-01

    A comparison study of pulse-shape analysis techniques was conducted for a BC501A scintillator using digital signal processing (DSP). In this study, output signals from a preamplifier were input directly into a 1 GHz analog-to-digital converter. The digitized data obtained with this method was post-processed for both pulse-height and pulse-shape information. Several different analysis techniques were evaluated for neutron and gamma-ray pulse-shape discrimination. It was surprising that one of the simplest and fastest techniques resulted in some of the best pulse-shape discrimination results. This technique, referred to here as the Integral Ratio technique, was able to effectively process several thousand detector pulses per second. This paper presents the results and findings of this study for various pulse-shape analysis techniques with digitized detector signals.

  12. [Comparison of the image quality of conventional and digital radiography in lizards. Mammography technique versus digital detector system].

    Science.gov (United States)

    Bochmann, Monika; Ludewig, E; Pees, M

    2011-01-01

    A conventional high-resolution screen-film system (Film Kodak MIN-R S, Kodak MIN-R 2000) was compared with an indirect digital detector system (Varian PaxScan 4030E) for use in radiography of lizards. A total of 20 bearded dragons (Pogona vitticeps ) with body masses between 123 g and 487 g were investigated by using conventional and digital image acquisition techniques. The digital image was taken with the same dose as well as half the dose of the conventional radiograph. The study was conducted semi-blinded as the x-ray images were encoded and randomised. Five veterinarians with clinical experience in reptile medicine served as observers. Exactly defined structures in three anatomical regions were assessed using a three-step scale. Furthermore, the overall quality of the respective region was evaluated using a five-step scale. Evaluation of the data was done by visual grading analysis. None of the structures examined was assessed to be of significantly inferior quality on the digital images in comparison to the conventional radiographs. The majority of the results demonstrated an equal quality of both systems. For assessment of the lung tissue and the pulmonary vessels as well as the overall assessment of the lung, the digital radiographs with full dose were rated to be significantly superior in comparison to the film-screen system. Furthermore, the joint contours of the shoulder and cubital joints and the overall assessments of the humerus and the caudal coelomic cavity were rated significantly better on digital images with full dose compared to those with reduced dose. The digital flat panel detector technique examined in this study is equal or superior to the conventional high-resolution screen-film system used. Nevertheless, the practicability of a dose reduction is limited in bearded dragons. Digital imaging systems are progressively being used in veterinary practice. The results of the study demonstrate the useful application of the digital detector systems

  13. Fuzzy technique for microcalcifications clustering in digital mammograms.

    Science.gov (United States)

    Vivona, Letizia; Cascio, Donato; Fauci, Francesco; Raso, Giuseppe

    2014-06-24

    Mammography has established itself as the most efficient technique for the identification of the pathological breast lesions. Among the various types of lesions, microcalcifications are the most difficult to identify since they are quite small (0.1-1.0 mm) and often poorly contrasted against an images background. Within this context, the Computer Aided Detection (CAD) systems could turn out to be very useful in breast cancer control. In this paper we present a potentially powerful microcalcifications cluster enhancement method applicable to digital mammograms. The segmentation phase employs a form filter, obtained from LoG filter, to overcome the dependence from target dimensions and to optimize the recognition efficiency. A clustering method, based on a Fuzzy C-means (FCM), has been developed. The described method, Fuzzy C-means with Features (FCM-WF), was tested on simulated clusters of microcalcifications, implying that the location of the cluster within the breast and the exact number of microcalcifications are known.The proposed method has been also tested on a set of images from the mini-Mammographic database provided by Mammographic Image Analysis Society (MIAS) publicly available. The comparison between FCM-WF and standard FCM algorithms, applied on both databases, shows that the former produces better microcalcifications associations for clustering than the latter: with respect to the private and the public database we had a performance improvement of 10% and 5% with regard to the Merit Figure and a 22% and a 10% of reduction of false positives potentially identified in the images, both to the benefit of the FCM-WF. The method was also evaluated in terms of Sensitivity (93% and 82%), Accuracy (95% and 94%), FP/image (4% for both database) and Precision (62% and 65%). Thanks to the private database and to the informations contained in it regarding every single microcalcification, we tested the developed clustering method with great accuracy. In particular

  14. Study of optical techniques for the Ames unitary wind tunnel: Digital image processing, part 6

    Science.gov (United States)

    Lee, George

    1993-01-01

    A survey of digital image processing techniques and processing systems for aerodynamic images has been conducted. These images covered many types of flows and were generated by many types of flow diagnostics. These include laser vapor screens, infrared cameras, laser holographic interferometry, Schlieren, and luminescent paints. Some general digital image processing systems, imaging networks, optical sensors, and image computing chips were briefly reviewed. Possible digital imaging network systems for the Ames Unitary Wind Tunnel were explored.

  15. Applications of digital scintillation imaging technique in medical and nuclear research

    International Nuclear Information System (INIS)

    Sinha, Amar

    2001-01-01

    This paper reviews various applications of digital scintillation imaging technique particularly those related to medical and nuclear research. Use of various scintillators, their advantages and limitations for different applications will be discussed in this paper. Work being carried out at BARC in the field of digital medical imaging, x-ray diffraction imaging using CCD detectors, digital neutron imaging, nuclear particle imaging will also be emphasised in this paper. (author)

  16. Application of digital compression techniques to optical surveillance systems

    International Nuclear Information System (INIS)

    Johnson, C.S.

    1991-01-01

    There are many benefits to handling video images electronically, however, the amount of digital data in a normal video image is a major obstacle. The solution is to remove the high frequency and redundant information in a process that is referred to as compression. Compression allows the number of digital bits required for a given image to be reduced for more efficient storage or transmission of images. The next question is how much compression can be done without impairing the image quality beyond its usefulness for a given application. This paper discusses image compression that might be applied to provide useful images in unattended nuclear facility surveillance applications

  17. Technical innovation: Multidimensional computerized software enabled subtraction computed tomographic angiography.

    Science.gov (United States)

    Bhatia, Mona; Rosset, Antoine; Platon, Alexandra; Didier, Dominique; Becker, Christoph D; Poletti, Pierre-Alexandre

    2010-01-01

    Computed tomographic angiography (CTA) is a frequent noninvasive alternative to digital subtraction angiography. We previously reported the development of a new subtraction software to overcome limitations of adjacent bone and calcification in CT angiographic subtraction. Our aim was to further develop and improve this fast and automated computerized software, universally available for free use and compatible with most CT scanners, thus enabling better delineation of vascular structures, artifact reduction, and shorter reading times with potential clinical benefits. This computer-based free software will be available as an open source in the next release of OsiriX at the Web site http://www.osirix-viewer.com.

  18. Localisation of parathyroid glands using planar {sup 99m}Tc-sestamibi scintigraphy. Comparison between subtraction- and dual-phase technique; Lokalisation von Nebenschilddruesenadenomen mit planarer {sup 99m}Tc-Sestamibi-Szintigraphie. Vergleich von Subtraktions- und 2-Phasen-Technik

    Energy Technology Data Exchange (ETDEWEB)

    Schommartz, B.; Antke, C.; Schmidt, D.; Mueller, H.W. [Nuklearmedizinische Klinik, Heinrich-Heine-Univ. Duesseldorf (Germany); Cupisti, K.; Knoefel, W.T. [Klinik fuer Allgemein- und Viszeralchirurgie, Heinrich-Heine-Univ. Duesseldorf (Germany)

    2006-07-01

    Aim: in the context of presurgical localisation of parathyroid adenomas in primary hyperparathyreoidism (pHPT) using {sup 99m}Tc-sestamibi scintigraphy, subtraction- and dual-phase technique are compared with each other and with the surgical findings. Patients, methods: prospectively, 126 patients with pHPT were investigated presurgically. For visualisation of parathyroid adenomas, an image of the thyroid ({sup 99m}Tc-pertechnetat) was subtracted from a perfusion image ({sup 99m}Tc-sestamibi) and 2 h p. i. another image was acquired for identification of retention of activity. Considering both techniques the clinical findings were reported promptly. Retrospectively, the evaluations were presented separately to four experienced raters. Results: in clinical routine for 109 patients correct findings were reported presurgically (87%). From 129 resected parathyroid adenomas 118 were localised correctly (sensitivity 91%, positive predictive value 94%). Concerning the retrospective analysis, in 75% of the cases both techniques provided the correct site, in 14% only the dual-phase technique and in 7% only the subtraction-technique was correct. With the help of the dual-phase technique significantly more investigations were correctly rated than with the help of the subtraction-technique (88,7 {+-} 3,2% vs. 81,6 {+-} 1,2%, p <0.01, two-sided t-test). Conclusion: the presurgical scintigraphic localisation of hyperactive parathyroid glands in pHPT assists minimal invasive surgery serving a high rate of correct findings. According to our data the dual-phase technique seems to be more sensitive than the subtraction technique. In some cases, however, the correct site may only be found using the subtraction technique. For an optimal surgical strategy we suggest the combination of both techniques. (orig.)

  19. Digital radiography and advanced imaging techniques in dentistry

    Directory of Open Access Journals (Sweden)

    Burcu Keles Evlice

    2013-04-01

    Full Text Available Since the discovery of x-rays in 1895, film has been the primary medium for capturing, displaying and storing radiographic images. Digital or filmless radiography is slowly being adopted by the dental profession. Digital radiography offers a number of capabilities compared with conventional radiography, such as postprocessing, electronic archiving, concurrent access to images, and improved data distribution. Computer based applications which are used for quantitative measurements and evaluations on digital images for better user interpretation. New diagnostic imaging processes are improved connected with the technological progress of computer systems. Since the first clinical use of computed tomography (CT scans in 1972, technological development has been rapid. Dental volumetric tomography (DVT, uniquely used for dentomaxillofacial imaging came to the market owing to recent rapid developments in digital radiology technology and is becoming more popular in dental applications. Low radiation dose cone beam computed tomography (CBCT units that are commercially available at a lower cost than CT units, has performed valuable diagnostic information for dentists. [Archives Medical Review Journal 2013; 22(2.000: 230-238

  20. Bus-oriented digital control techniques in nuclear power plants

    International Nuclear Information System (INIS)

    Salm, M.

    1987-01-01

    The author states the conservative principles which govern the authorization procedures for nuclear reactor control systems. Using the example of a feedwater supply regulator, employing a digital, bus-oriented control system, he describes how the stigma attached to the word nuclear can be alleviated. (G.T.H.)

  1. Digital autoradiography technique for studying of spatial Impurity distributions Delara

    International Nuclear Information System (INIS)

    Khamrayeva, S.

    2001-01-01

    In this report, the possibilities of the digital image processing for autoradiographic investigations of impurity distributions in the different objects (crystals, biology, geology et al) are shown. Activation autoradiography based on the secondary beta-irradiation is the method spread widely for investigations of the spatial distribution of chemical elements in the different objects. The analysis of autoradiography features is connected with the elucidation of optical density distribution of photoemulsion by means of photometry. The photoemulsion is used as detector of secondary beta irradiation. For different technological and nature materials to have elemental shifts the fine structure of chemical element distribution is often interested. But photometry makes it difficult to study the inhomogeneous chemical elements with the little gradient of concentration (near 20%). Therefore, the suppression of the background and betterment of linear solvability are the main problems of autoradiographic analysis. Application of the fast-acting digital computers and the technical means of signals treatment are allowed to spread the possibilities and the resolution of activation autoradiography. Mechanism of creation of autoradiographic features is described. The treatment of autoradiograms was conducted with the help of the dialogue system having matrix in 512 x 512 elements. For the interpretation of the experimental data clustering analysis methodology was used. Classification of the zones on the minimum of the square mistake was conducted according to the data of histograms of the optical densities of the studying autoradiograms. It was proposed algorithm for digital treatment for reconstruction of autoradiographic features. At a minimal contrast the resolution of the method has been enhanced on the degree by adaptation of methods of digital image processing (DIP) to suppress background activity. Results of the digital autoradiographic investigations of spatial impurity

  2. Chebyshev-based technique for automated restoration of digital copies of faded photographic prints

    Science.gov (United States)

    Uchaev, Dmitry V.; Uchaev, Denis V.; Malinnikov, Vasiliy A.

    2017-01-01

    We present a technique for automated restoration of digital images obtained from faded photographic prints. The proposed defading technique uses our early proposed image contrast enhancement algorithm based on a contrast measure of images in the Chebyshev moment transform domain. Obtained experimental results demonstrate some advantages of the technique as compared to other widely used image enhancement methods.

  3. Imaging techniques in digital forensic investigation: a study using neural networks

    Science.gov (United States)

    Williams, Godfried

    2006-09-01

    Imaging techniques have been applied to a number of applications, such as translation and classification problems in medicine and defence. This paper examines the application of imaging techniques in digital forensics investigation using neural networks. A review of applications of digital image processing is presented, whiles a Pedagogical analysis of computer forensics is also highlighted. A data set describing selected images in different forms are used in the simulation and experimentation.

  4. A CLASSICAL REVIEW ON ADVANCED DIGITAL IMAGE WATERMARKING TECHNIQUES

    OpenAIRE

    BAISA L. GUNJAL

    2018-01-01

    The world has become a global village in digital era due to advances in internet and communication technology. Presently, creation, copy and transmission of image data via internet and mobile phone are very common practices. The access, sharing, replication and manipulation of medical images have become daily needs. Image data distributed can be copied repeatedly without errors putting the rights of owners at risk. Even though encrypted for distribution, images can be unprotected after decryp...

  5. sup(99m)Tc particle perfusion/sup(99m)Tc aerosol ventilation imaging using a subtraction technique in suspected pulmonary embolism

    International Nuclear Information System (INIS)

    Poeyhoenen, L.; Turjanmaa, V.; Virjo, A.

    1985-01-01

    It is generally acknowledged that ventilation-perfusion mismatch is diagnostic of pulmonary embolism. Lung ventilation imaging with radioactive gases is a good method for the detection of pulmonary embolism, but it is not in widespread use because of the limited availability of sup(81m)Kr gas and the poor physical properties of 133 Xe. Aerosols have been proposed, instead of gases for use in lung ventilation imaging. As perfusion and ventilation distributions may change very rapidly, the two imaging procedures should be done in rapid succession. The cheapest way to perform the combined perfusion-ventilation (Q/V) imaging is to use sup(99m)Tc-labelled macroaggregates and aerosols. In our method the perfusion imaging was done first, immediately followed by the ventilation imaging with sup(99m)Tc-labelled aerosols. A computer program was used to subtract the contribution of the perfusion from the combined Q/V image so that the pure ventilation image alone was obtained. The method was tested in 41 patients with suspected pulmonary embolism. (orig.)

  6. Optimal fringe angle selection for digital fringe projection technique.

    Science.gov (United States)

    Wang, Yajun; Zhang, Song

    2013-10-10

    Existing digital fringe projection (DFP) systems mainly use either horizontal or vertical fringe patterns for three-dimensional shape measurement. This paper reveals that these two fringe directions are usually not optimal where the phase change is the largest to a given depth variation. We propose a novel and efficient method to determine the optimal fringe angle by projecting a set of horizontal and vertical fringe patterns onto a step-height object and by further analyzing two resultant phase maps. Experiments demonstrate the existence of the optimal angle and the success of the proposed optimal angle determination method.

  7. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    International Nuclear Information System (INIS)

    Burgmans, M.C.; Too, C.W.; Kao, Y.H.; Goh, A.S.W.; Chow, P.K.H.; Tan, B.S.; Tay, K.H.; Lo, R.H.G.

    2012-01-01

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  8. Computed tomography hepatic arteriography has a hepatic falciform artery detection rate that is much higher than that of digital subtraction angiography and 99mTc-MAA SPECT/CT: Implications for planning 90Y radioembolization?

    Energy Technology Data Exchange (ETDEWEB)

    Burgmans, M.C., E-mail: mburgmans@hotmail.com [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Too, C.W., E-mail: too.chow.wei@singhealth.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Kao, Y.H., E-mail: yung.h.kao@gmail.com [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Goh, A.S.W., E-mail: anthony.goh.s.w@sgh.com.sg [Department of Nuclear Medicine and PET, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Chow, P.K.H., E-mail: gsupc@singnet.com.sg [Department of General Surgery, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Office of Clinical Sciences, Duke-NUS Graduate Medical School Singapore, 8 College Road, Singapore 169857 (Singapore); Department of Surgical Oncology, National Cancer Center Singapore, 11 Hospital Drive, Singapore 169610 (Singapore); Tan, B.S., E-mail: tan.bien.soo@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Tay, K.H., E-mail: tay.kiang.hiong@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore); Lo, R.H.G., E-mail: richard.lo.h.g@sgh.com.sg [Department of Diagnostic Radiology, Singapore General Hospital, Outram Road, Singapore 169608 (Singapore)

    2012-12-15

    Purpose: To compare the hepatic falciform artery (HFA) detection rates of digital subtraction angiography (DSA), computed tomography hepatic arteriography (CTHA) and 99mTc-macroaggregated albumin (99mTc-MAA) single photon emission computed tomography with integrated CT (SPECT/CT) and to correlate HFA patency with complication rates of yttrium-90 (90Y) radioembolization. Material and methods: From August 2008 to November 2010, 79 patients (range 23–83 years, mean 62.3 years; 67 male) underwent pre-treatment DSA, CTHA and 99mTc-MAA scintigraphy (planar/SPECT/CT) to assess suitability for radioembolization with 90Y resin microspheres. Thirty-seven patients were excluded from the study, because CTHA was performed with a catheter position that did not result in opacification of the liver parenchyma adjacent to the falciform ligament. DSA, CTHA and 99mTc-MAA SPECT/CT images and medical records were retrospectively reviewed. Results: A patent HFA was detected in 22 of 42 patients (52.3%). The HFA detection rates of DSA, CTHA and 99mTc-MAA SPECT/CT were 11.9%, 52.3% and 13.3%, respectively (p < 0.0001). An origin from the segment 4 artery was seen in 51.7% of HFAs. Prophylactic HFA coil-embolization prior to 90Y microspheres infusion was performed in 2 patients. Of the patients who underwent radioembolization with a patent HFA, none developed supra-umbilical radiation dermatitis. One patient experienced epigastric pain attributed to post-embolization syndrome and was managed conservatively. Conclusion: The HFA detection rate of CTHA is superior to that of DSA and 99mTc-MAA SPECT/CT. Complications related to non-target radiation of the HFA vascular territory rarely occur, even in patients undergoing radioembolization with a patent HFA.

  9. Application of digital image processing techniques to astronomical imagery 1978

    Science.gov (United States)

    Lorre, J. J.

    1978-01-01

    Techniques for using image processing in astronomy are identified and developed for the following: (1) geometric and radiometric decalibration of vidicon-acquired spectra, (2) automatic identification and segregation of stars from galaxies; and (3) display of multiband radio maps in compact and meaningful formats. Examples are presented of these techniques applied to a variety of objects.

  10. Digital microfluidics: A promising technique for biochemical applications

    Science.gov (United States)

    Wang, He; Chen, Liguo; Sun, Lining

    2017-12-01

    Digital microfluidics (DMF) is a versatile microfluidics technology that has significant application potential in the areas of automation and miniaturization. In DMF, discrete droplets containing samples and reagents are controlled to implement a series of operations via electrowetting-on-dielectric. This process works by applying electrical potentials to an array of electrodes coated with a hydrophobic dielectric layer. Unlike microchannels, DMF facilitates precise control over multiple reaction processes without using complex pump, microvalve, and tubing networks. DMF also presents other distinct features, such as portability, less sample consumption, shorter chemical reaction time, flexibility, and easier combination with other technology types. Due to its unique advantages, DMF has been applied to a broad range of fields (e.g., chemistry, biology, medicine, and environment). This study reviews the basic principles of droplet actuation, configuration design, and fabrication of the DMF device, as well as discusses the latest progress in DMF from the biochemistry perspective.

  11. Application of digital techniques to the restoration of radiographic images

    International Nuclear Information System (INIS)

    Burch, S.F.

    1980-09-01

    The methods of constrained least squares and maximum entropy have been used to restore digital X and γ-ray radiographs. Both methods require the blurring of the image to be a linear, spatially invariant process. Although the blurring processes in radiography can be complex, situations have been identified where these simplifying assumptions are valid. Algorithms for deriving the point-spread function of each image are discussed. These include a pinhole method for X-ray radiographs, and reconstruction from edge profiles for γ-ray radiographs. The results from the restoration of geometrically blurred radiographs of sparking plugs are given. Maximum entropy gives results superior to those obtained by constrained least squares. The resolution is improved by a factor of about three when maximum entropy is used, and by a factor of about two for constrained least squares. (author)

  12. Evaluation of the quality of different endodontic obturation techniques by digital radiography.

    Science.gov (United States)

    Fracassi, Larissa Dantas; Ferraz, Eduardo Gomes; Albergaria, Sílvio José; Veeck, Elaine Bauer; da Costa, Nilza Pereira; Sarmento, Viviane Almeida

    2013-01-01

    This study was aimed to evaluate different endodontic obturation techniques (Thermafil, lateral condensation, and Tagger's hybrid technique) regarding the homogeneity of the obturation radiopacity. Seventy roots of human upper central incisors were filled using the Thermafil system, lateral condensation. and Tagger's hybrid technique. Radiopacity of the filling was evaluated based on mean of grey levels, and its homogeneity was assessed by the coefficient of variation (CV), analyzing the histograms obtained of digitized and digital radiographs. The increase in mean grey levels (p technique compared with other methods. Tagger's hybrid technique provided better homogeneity of the obturation radiopacity and better apical sealing compared with lateral condensation technique. The results suggest that Tagger's hybrid technique provided the best compaction of the root canal filling material, an important factor for the sealing of obturations and, consequently, for the effectiveness of treatment.

  13. Application of digital sampling techniques to particle identification in scintillation detectors

    International Nuclear Information System (INIS)

    Bardelli, L.; Bini, M.; Poggi, G.; Taccetti, N.

    2002-01-01

    In this paper, the use of a fast digitizing system for identification of fast charged particles with scintillation detectors is discussed. The three-layer phoswich detectors developed in the framework of the FIASCO experiment for the detection of light charged particles (LCP) and intermediate mass fragments (IMF) emitted in heavy-ion collisions at Fermi energies are briefly discussed. The standard analog electronics treatment of the signals for particle identification is illustrated. After a description of the digitizer designed to perform a fast digital sampling of the phoswich signals, the feasibility of particle identification on the sampled data is demonstrated. The results obtained with two different pulse shape discrimination analyses based on the digitally sampled data are compared with the standard analog signal treatment. The obtained results suggest, for the present application, the replacement of the analog methods with the digital sampling technique

  14. Digital subtraction angiography for lower extremity phlebography

    International Nuclear Information System (INIS)

    Yokoyama, Kunihiko; Nakashima, Noriko; Takata, Yasunori; Hashimoto, Shozo.

    1989-01-01

    DSA was applied to the lower extremity phlebography on 21 cases (36 legs). The patient lay in the supine position and a tourniquet was placed around the ankle. Forty ml of contrast medium, diluted to 25% of the original concentration with normal saline, was injected into the dorsal vein of the foot. The anterior tibial vein, posterior tibial vein, peroneal vein and muscular vein of the calf were identified in 24(63.2%), 36(94.7%), 37(97.4%) and 7 legs (18.4%), respectively. The poor opacification of the anterior tibial vein was attributed partly to the compression effect of the tourniquet. The abnormal findings were deep vein thrombosis (5 legs), reflux from the deep to the superficial vein (14 legs) and irregularity of the vein wall (16 legs). The superficial varicose veins were not demonstrated in DSA phlebography. The examination was comfortable because the patient position was supine and the dilute contrast medium caused no burning sensation. We believe that DSA phelobography is a safe and useful method for diagnosing the deep venous system disorders. (author)

  15. Digital subtraction angiography for lower extremity phlebography

    Energy Technology Data Exchange (ETDEWEB)

    Yokoyama, Kunihiko; Nakashima, Noriko; Takata, Yasunori; Hashimoto, Shozo.

    1989-04-01

    DSA was applied to the lower extremity phlebography on 21 cases (36 legs). The patient lay in the supine position and a tourniquet was placed around the ankle. Forty ml of contrast medium, diluted to 25% of the original concentration with normal saline, was injected into the dorsal vein of the foot. The anterior tibial vein, posterior tibial vein, peroneal vein and muscular vein of the calf were identified in 24(63.2%), 36(94.7%), 37(97.4%) and 7 legs (18.4%), respectively. The poor opacification of the anterior tibial vein was attributed partly to the compression effect of the tourniquet. The abnormal findings were deep vein thrombosis (5 legs), reflux from the deep to the superficial vein (14 legs) and irregularity of the vein wall (16 legs). The superficial varicose veins were not demonstrated in DSA phlebography. The examination was comfortable because the patient position was supine and the dilute contrast medium caused no burning sensation. We believe that DSA phelobography is a safe and useful method for diagnosing the deep venous system disorders. (author).

  16. Ring Laser Gyro-based Digital Processing Technique for Detecting Rotation Rate over Short Time Intervals

    Directory of Open Access Journals (Sweden)

    V. N. Enin

    2017-01-01

    Full Text Available The article investigates capabilities of digital techniques to improve measurement accuracy of dithering ring laser gyro (DRLG in detecting constant rotation rate over short time intervals. An array of the GL-1 device output within a LG triad to measure the vertical component of the angular rate of rotation of the Earth in the laboratory setting is selected as the object of study. The selected time of a single measurement is 2 minutes, and as a full standard deviation error of measurement is selected the magnitude at least 0.002 "/ min. The objective of this study is to develop and underpin a new effective technique of LG digital information processing to enable providing an appropriate accuracy to meet modern requirements with reducing measurement time of a constant rate Ωz component. The specific objectives are the comparative analysis of the precision capabilities of the known techniques over limited measurement time intervals, development and support of new, more efficient technique of digital information processing of dithering ring LG, and experimental verification and evaluation of effectiveness of the technique proposed. The article presents a comparative error analysis of practically applied digital techniques such a simple averaging method, Hamming method, and method of "conditional sample of regression lines" with the proposed technique of "recognition of the output signal of the image N". To compare the techniques were used the real digital processing device output data taken at a frequency of 400 Hz over 94 two-minute measurement intervals after the device has been switched on. The proposed LG output image recognition technique enables us to reach about three times higher measuring accuracy over two-minute interval as compared to the known techniques.

  17. Applying the digital-image-correlation technique to measure the ...

    Indian Academy of Sciences (India)

    It has been applied for analysing various structural problems. For exam- ple, French scholars Raffard et ... observe the crack development in masonry wall. One major advantage of DIC technique ... based on the characteristic gray-scale distributions in the image of the structural speckle on the specimen surface. As shown in ...

  18. Applying the digital-image-correlation technique to measure the ...

    Indian Academy of Sciences (India)

    4.2 Image analysis. The DIC technique is used to analyse the column deformation. After the position of every mark is traced, two parallel observation lines on the surface of column (as shown in figure 8) are cho- sen. There are 181 equal spaced points on each line. The positions of these points are calculated using B-Spline ...

  19. Experimental study of digital image processing techniques for LANDSAT data

    Science.gov (United States)

    Rifman, S. S. (Principal Investigator); Allendoerfer, W. B.; Caron, R. H.; Pemberton, L. J.; Mckinnon, D. M.; Polanski, G.; Simon, K. W.

    1976-01-01

    The author has identified the following significant results. Results are reported for: (1) subscene registration, (2) full scene rectification and registration, (3) resampling techniques, (4) and ground control point (GCP) extraction. Subscenes (354 pixels x 234 lines) were registered to approximately 1/4 pixel accuracy and evaluated by change detection imagery for three cases: (1) bulk data registration, (2) precision correction of a reference subscene using GCP data, and (3) independently precision processed subscenes. Full scene rectification and registration results were evaluated by using a correlation technique to measure registration errors of 0.3 pixel rms thoughout the full scene. Resampling evaluations of nearest neighbor and TRW cubic convolution processed data included change detection imagery and feature classification. Resampled data were also evaluated for an MSS scene containing specular solar reflections.

  20. In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques

    Science.gov (United States)

    Kamimura, Emi; Tanaka, Shinpei; Takaba, Masayuki; Tachi, Keita; Baba, Kazuyoshi

    2017-01-01

    Purpose The aim of this study was to evaluate and compare the inter-operator reproducibility of three-dimensional (3D) images of teeth captured by a digital impression technique to a conventional impression technique in vivo. Materials and methods Twelve participants with complete natural dentition were included in this study. A digital impression of the mandibular molars of these participants was made by two operators with different levels of clinical experience, 3 or 16 years, using an intra-oral scanner (Lava COS, 3M ESPE). A silicone impression also was made by the same operators using the double mix impression technique (Imprint3, 3M ESPE). Stereolithography (STL) data were directly exported from the Lava COS system, while STL data of a plaster model made from silicone impression were captured by a three-dimensional (3D) laboratory scanner (D810, 3shape). The STL datasets recorded by two different operators were compared using 3D evaluation software and superimposed using the best-fit-algorithm method (least-squares method, PolyWorks, InnovMetric Software) for each impression technique. Inter-operator reproducibility as evaluated by average discrepancies of corresponding 3D data was compared between the two techniques (Wilcoxon signed-rank test). Results The visual inspection of superimposed datasets revealed that discrepancies between repeated digital impression were smaller than observed with silicone impression. Confirmation was forthcoming from statistical analysis revealing significantly smaller average inter-operator reproducibility using a digital impression technique (0.014± 0.02 mm) than when using a conventional impression technique (0.023 ± 0.01 mm). Conclusion The results of this in vivo study suggest that inter-operator reproducibility with a digital impression technique may be better than that of a conventional impression technique and is independent of the clinical experience of the operator. PMID:28636642

  1. CT digital radiography: Alternative technique for airway evaluation in physically disabled patients

    International Nuclear Information System (INIS)

    Mandell, G.A.; Harcke, H.T.; Brunson, G.; Delengowski, R.; Padman, R.

    1987-01-01

    Evaluation of the airway for the presence of granulation tissue prior to removal of a tracheostomy is essential to prevent sudden respiratory decompensation secondary to obstruction. Airway examination in a brain and/or spinal cord injured patient is especially difficult under fluoroscopy. The patient's lack of mobility results in poor visualization of the trachea, secondary to the overlying dense osseous components of the shoulders and thoracic cage. A CT localization view (digital view), which allows manipulation and magnification of the digital data in order to see the hidden airway and detect associated obstructing lesions, is proffered as an alternative technique to high KV, magnification technique. Thirteen examinations were performed satisfactorily in eleven patients examined by this technique with little expenditure of time, physical exertion, and irradiation. The sensitivity, specificity and accuracy of digital airway examination were 100%, 67% and 92% respectively with bronchoscopy used as the standard. (orig.)

  2. [Construction of subtractive cDNA libraries of the sporogony stage of Eimeria tenella by suppression subtractive hybridization].

    Science.gov (United States)

    Han, Hong-Yu; Lin, Jiao-Jiao; Zhao, Qi-Ping; Dong, Hui; Jiang, Lian-Lian; Wang, Xin; Han, Jing-Fang; Huang, Bing

    2007-11-01

    In order to clone and identify differentially expressed genes in the sporogony stage of Eimeria tenella, the cDNAs from unsporulated oocysts and sporulated oocysts of E. tenella were used as driver, respectively, the cDNAs from sporozoites of E. tenella was used tester, Two subtractive cDNA libraries of sporozoites were constructed by using the technique of suppression subtractive hybridization (SSH). the cDNAs from unsporulated oocysts was used driver, the cDNAs from sporulated ooceysts was used tester, one subtractive cDNA library of sporulated oocysts was constructed. PCR amplification revealed that the two subtractive cDNA libraries of sporozoites and one subtractive cDNA library of sporulated oocysts contained approximated 96%, 96% and 98% recombinant clones, respectively. Fifty positive clones were sequenced and analyzed in GenBank with Blast search from three subtractive cDNA libraries, respectively, thirteen unique sequences were found from the subtractive cDNA library of sporulated oocysts, eight ESTs shared significant identity with previously described. A total of forty unique sequences were obtained from the two subtractive cDNA libraries, nine ESTs shared significant identity with previously described, the other sequences represent novel genes of E. tenella with no significant homology to the proteins in Genbank. These results have provided the foundation for cloning new genes of E. tenella and further studying new approaches to control coccidiosis.

  3. Dental Students' Perceptions of Digital and Conventional Impression Techniques: A Randomized Controlled Trial.

    Science.gov (United States)

    Zitzmann, Nicola U; Kovaltschuk, Irina; Lenherr, Patrik; Dedem, Philipp; Joda, Tim

    2017-10-01

    The aim of this randomized controlled trial was to analyze inexperienced dental students' perceptions of the difficulty and applicability of digital and conventional implant impressions and their preferences including performance. Fifty undergraduate dental students at a dental school in Switzerland were randomly divided into two groups (2×25). Group A first took digital impressions in a standardized phantom model and then conventional impressions, while the procedures were reversed for Group B. Participants were asked to complete a VAS questionnaire (0-100) on the level of difficulty and applicability (user/patient-friendliness) of both techniques. They were asked which technique they preferred and perceived to be more efficient. A quotient of "effective scan time per software-recorded time" (TRIOS) was calculated as an objective quality indicator for intraoral optical scanning (IOS). The majority of students perceived IOS as easier than the conventional technique. Most (72%) preferred the digital approach using IOS to take the implant impression to the conventional method (12%) or had no preference (12%). Although total work was similar for males and females, the TRIOS quotient indicated that male students tended to use their time more efficiently. In this study, dental students with no clinical experience were very capable of acquiring digital tools, indicating that digital impression techniques can be included early in the dental curriculum to help them catch up with ongoing development in computer-assisted technologies used in oral rehabilitation.

  4. Application of digital image processing techniques to astronomical imagery, 1979

    Science.gov (United States)

    Lorre, J. J.

    1979-01-01

    Several areas of applications of image processing to astronomy were identified and discussed. These areas include: (1) deconvolution for atmospheric seeing compensation; a comparison between maximum entropy and conventional Wiener algorithms; (2) polarization in galaxies from photographic plates; (3) time changes in M87 and methods of displaying these changes; (4) comparing emission line images in planetary nebulae; and (5) log intensity, hue saturation intensity, and principal component color enhancements of M82. Examples are presented of these techniques applied to a variety of objects.

  5. Two techniques for mapping and area estimation of small grains in California using Landsat digital data

    Science.gov (United States)

    Sheffner, E. J.; Hlavka, C. A.; Bauer, E. M.

    1984-01-01

    Two techniques have been developed for the mapping and area estimation of small grains in California from Landsat digital data. The two techniques are Band Ratio Thresholding, a semi-automated version of a manual procedure, and LCLS, a layered classification technique which can be fully automated and is based on established clustering and classification technology. Preliminary evaluation results indicate that the two techniques have potential for providing map products which can be incorporated into existing inventory procedures and automated alternatives to traditional inventory techniques and those which currently employ Landsat imagery.

  6. Quantitative analysis of alveolar bone change following implant placement using intraoral radiographic subtraction

    International Nuclear Information System (INIS)

    Kimura, Hiroyuki; Kanda, Shigenobu; Tanaka, Takemasa

    2002-01-01

    The purpose of this study was to develop a procedure for quantitative analysis using intraoral radiographs of alveolar bone after placement of dental implants and to consider the validity of the method. We evaluated the ten patients (2 males and 8 females, average age: 48.4 years-old), who were treated with dental implant operation in the site of mandibular molar region, since October of 1999 until September of 2000 in Kimura Dental Clinic (Kumamoto, Japan). We evaluated the intraoral radiographs taken pre- and post- operatively and at follow-up examination. To detect alveolar bone change on radiograph, we adopted the digital subtraction method. Although the radiographs were taken under an ordinary technique with cone indicator, we did not apply the standardized technique with fixing material customized for each patient. Therefore, we used geometric correction and density compensation before subtraction. We assessed the basic statistical values (mean, variance, kurtosis and skewness) of the region of interest (ROI) of the subtracted images. Also, we noted PPD (probing pocket depth) and BOP (bleeding on probing) at each site as indicators of clinical findings and all implanted sites were classified according to the PPD or BOP, i.e. PPD increased group ''PPD (+)'' and PPD stable group ''PPD (-)'', likewise BOP positive group ''BOP (+)'' and negative group ''BOP (-)''. We considered the statistical values of ROI in each group and compared these findings. Mean and variance values of PPD (+) were higher than those of PPD (-) and there was a significant difference in mean value (p=0.031). Similarly, mean and variance values of BOP (+) were statistically higher than those of BOP (-) (p=0.041 and p=0.0087, respectively). Concerning kurtosis and skewness, there was no difference between PPD (+) and PPD (-), or between BOP (+) and BOP (-). Using our method, the radiographs taken for follow-up examination could be assessed quantitatively. It is suggested that geometric

  7. Procedures and Techniques for the PSA of Digital I and C System

    International Nuclear Information System (INIS)

    Kang, Hyun Gook; Eom, Heung Sup; Jang, Seung Cheol

    2006-01-01

    UCN 5 and 6 nuclear units (OPR-1000) are being constructed and the Korean Next Generation Reactor (APR-1400) is being designed by using digital I and C equipment for the safety functions such as a reactor protection system, an engineered safety feature actuation system, and a safety equipment control system. Even though the use of digital equipment for safety-related functions provides many advantageous features, there are still many arguable safety issues remaining. Design, configuration management and maintenance are important application areas for the probabilistic safety assessment (PSA). Digital I and C systems are natural candidates for PSA applications. From the viewpoint of the PSA, the digital techniques are very different from the conventional techniques of analog I and C systems because of some unique features. This article aims at giving an overview for the important issues of digital system PSA and at presenting the current status of technology development for each issue. Korea Atomic Energy Research Institute (KAERI) has performed an initiative research in order to meet risk information needs for digitalized safety-critical systems in Korea. The technologies presented in this article especially focusing on those developed in the KAERI

  8. Watermarking Techniques Using Least Significant Bit Algorithm for Digital Image Security Standard Solution- Based Android

    Directory of Open Access Journals (Sweden)

    Ari Muzakir

    2017-05-01

    Full Text Available Ease of deployment of digital image through the internet has positive and negative sides, especially for owners of the original digital image. The positive side of the ease of rapid deployment is the owner of that image deploys digital image files to various sites in the world address. While the downside is that if there is no copyright that serves as protector of the image it will be very easily recognized ownership by other parties. Watermarking is one solution to protect the copyright and know the results of the digital image. With Digital Image Watermarking, copyright resulting digital image will be protected through the insertion of additional information such as owner information and the authenticity of the digital image. The least significant bit (LSB is one of the algorithm is simple and easy to understand. The results of the simulations carried out using android smartphone shows that the LSB watermarking technique is not able to be seen by naked human eye, meaning there is no significant difference in the image of the original files with images that have been inserted watermarking. The resulting image has dimensions of 640x480 with a bit depth of 32 bits. In addition, to determine the function of the ability of the device (smartphone in processing the image using this application used black box testing. 

  9. 3D DIGITAL SIMULATION OF MINNAN TEMPLE ARCHITECTURE CAISSON'S CRAFT TECHNIQUES

    Directory of Open Access Journals (Sweden)

    Y. C. Lin

    2013-07-01

    Full Text Available Caisson is one of the important representations of the Minnan (southern Fujian temple architecture craft techniques and decorative aesthetics. The special component design and group building method present the architectural thinking and personal characteristics of great carpenters of Minnan temple architecture. In late Qing Dynasty, the appearance and style of caissons of famous temples in Taiwan apparently presented the building techniques of the great carpenters. However, as the years went by, the caisson design and craft techniques were not fully inherited, which has been a great loss of cultural assets. Accordingly, with the caisson of Fulong temple, a work by the well-known great carpenter in Tainan as an example, this study obtained the thinking principles of the original design and the design method at initial period of construction through interview records and the step of redrawing the "Tng-Ko" (traditional design, stakeout and construction tool. We obtained the 3D point cloud model of the caisson of Fulong temple using 3D laser scanning technology, and established the 3D digital model of each component of the caisson. Based on the caisson component procedure obtained from interview records, this study conducted the digital simulation of the caisson component to completely recode and present the caisson design, construction and completion procedure. This model of preserving the craft techniques for Minnan temple caisson by using digital technology makes specific contribution to the heritage of the craft techniques while providing an important reference for the digital preservation of human cultural assets.

  10. The Use of Procedural Knowledge in Simple Addition and Subtraction Problems

    Science.gov (United States)

    Fayol, Michel; Thevenot, Catherine

    2012-01-01

    In a first experiment, adults were asked to solve one-digit additions, subtractions and multiplications. When the sign appeared 150 ms before the operands, addition and subtraction were solved faster than when the sign and the operands appeared simultaneously on screen. This priming effect was not observed for multiplication problems. A second…

  11. Background subtraction theory and practice

    CERN Document Server

    Elgammal, Ahmed

    2014-01-01

    Background subtraction is a widely used concept for detection of moving objects in videos. In the last two decades there has been a lot of development in designing algorithms for background subtraction, as well as wide use of these algorithms in various important applications, such as visual surveillance, sports video analysis, motion capture, etc. Various statistical approaches have been proposed to model scene backgrounds. The concept of background subtraction also has been extended to detect objects from videos captured from moving cameras. This book reviews the concept and practice of back

  12. Constructing a Soil Class Map of Denmark based on the FAO Legend Using Digital Techniques

    DEFF Research Database (Denmark)

    Adhikari, Kabindra; Minasny, Budiman; Greve, Mette Balslev

    2014-01-01

    Soil mapping in Denmark has a long history and a series of soil maps based on conventional mapping approaches have been produced. In this study, a national soil map of Denmark was constructed based on the FAO–Unesco Revised Legend 1990 using digital soil mapping techniques, existing soil profile...... observations and environmental data. This map was developed using soil-landscape models generated with a decision tree-based digital soil mapping technique. As input variables in the model, more than 1170 soil profile data and 17 environmental variables including geology, land use, landscape type, area...... of wetlands, digital elevation model and its derivatives were compiled. The predicted map showed that Podzols and Luvisols were the most frequent soil groups, covering almost two-thirds of the area of Denmark. Geographically, Podzols occupied a major portion of western Denmark, where the soils have developed...

  13. A Clinical Comparative Study of 3-Dimensional Accuracy between Digital and Conventional Implant Impression Techniques.

    Science.gov (United States)

    Alsharbaty, Mohammed Hussein M; Alikhasi, Marzieh; Zarrati, Simindokht; Shamshiri, Ahmed Reza

    2018-02-09

    To evaluate the accuracy of a digital implant impression technique using a TRIOS 3Shape intraoral scanner (IOS) compared to conventional implant impression techniques (pick-up and transfer) in clinical situations. Thirty-six patients who had two implants (Implantium, internal connection) ranging in diameter between 3.8 and 4.8 mm in posterior regions participated in this study after signing a consent form. Thirty-six reference models (RM) were fabricated by attaching two impression copings intraorally, splinted with autopolymerizing acrylic resin, verified by sectioning through the middle of the index, and rejoined again with freshly mixed autopolymerizing acrylic resin pattern (Pattern Resin) with the brush bead method. After that, the splinted assemblies were attached to implant analogs (DANSE) and impressed with type III dental stone (Gypsum Microstone) in standard plastic die lock trays. Thirty-six working casts were fabricated for each conventional impression technique (i.e., pick-up and transfer). Thirty-six digital impressions were made with a TRIOS 3Shape IOS. Eight of the digitally scanned files were damaged; 28 digital scan files were retrieved to STL format. A coordinate-measuring machine (CMM) was used to record linear displacement measurements (x, y, and z-coordinates), interimplant distances, and angular displacements for the RMs and conventionally fabricated working casts. CATIA 3D evaluation software was used to assess the digital STL files for the same variables as the CMM measurements. CMM measurements made on the RMs and conventionally fabricated working casts were compared with 3D software measurements made on the digitally scanned files. Data were statistically analyzed using the generalized estimating equation (GEE) with an exchangeable correlation matrix and linear method, followed by the Bonferroni method for pairwise comparisons (α = 0.05). The results showed significant differences between the pick-up and digital groups in all of the

  14. Identification of differential genes by suppression subtractive hybridization: I. Preparation of subtracted cDNA or genomic DNA library.

    Science.gov (United States)

    Rebrikov, Denis V

    2008-07-01

    INTRODUCTIONSuppression subtractive hybridization (SSH) is one of the most powerful and popular methods for generating subtracted cDNA or genomic DNA libraries. This technique can be used to compare two mRNA populations and obtain cDNAs representing genes that are either overexpressed or exclusively expressed in one population as compared to another. It can also be used for comparison of genomic DNA populations. This protocol describes the preparation of a subtracted cDNA or genomic DNA library, and includes methods for cDNA synthesis, tester and driver DNA digestion, and adapter ligation.

  15. Digital documentation of complex architectures by integration of multiple techniques: the case study of Valer Castle

    Science.gov (United States)

    Voltolini, Francesca; El-Hakim, Sabry; Remondino, Fabio; Girardi, Stefano; Rizzi, Alessandro; Pontin, Marco; Gonzo, Lorenzo

    2007-01-01

    The digital documentation of monuments and architectures is an important field of application of the 3D modeling where both visual quality and precise 3D measurement are important. This paper proposes an integrated approach based upon the combination of different 3D modeling techniques for the virtual reconstruction of complex architectures like those found in medieval castles. The need of combining multiple techniques, like terrestrial laser scanning, photogrammetry and digital surveying comes from the complexity of some structures and by the lack of a single technique capable of giving satisfactory results in all measuring conditions. This paper will address modeling issues related to the automation of photogrammetric methods and to the fusion of 3D models acquired with different techniques, at different point densities and measurement accuracies. The test bench is a medieval castle placed in Trentino A.A., a tiny region in Northern Italy.

  16. An Efficient Digital Pulse Shape Discrimination Technique for Scintillation Detectors Based on FPGA

    International Nuclear Information System (INIS)

    Kamel, M.S.

    2014-01-01

    Different techniques for pulse discrimination (PSD) of the scintillation pulses have been developed. The PSD of scintillation pulese can been used in several applications as Positron Emission Topography (PET) system. Each technique analyzes the resulting pulses from the absorption of radiation in the scintillation pulses were filtered and digitized then it is captured using DAQ, and it sent to the host computer for processing. The spatial resolution of images that generated in PET system can be improved by applying the proposed PSD. In this thesis various digital PSD techniques are proposed to discriminate the scintillation pulses. These techniques are based on discrete sine transform (DST). discrete cosine transform (DCT). Discrete hartley transform (DHT), Discrete Goertzel transform (DGT),and principal component analysis (PCA). Then the output coefficients of the discrete transforms are classified using one of the following classifiers T-test,tuned, or support vector machine (SVM).

  17. Design of a digital voice data compression technique for orbiter voice channels

    Science.gov (United States)

    1975-01-01

    Candidate techniques were investigated for digital voice compression to a transmission rate of 8 kbps. Good voice quality, speaker recognition, and robustness in the presence of error bursts were considered. The technique of delayed-decision adaptive predictive coding is described and compared with conventional adaptive predictive coding. Results include a set of experimental simulations recorded on analog tape. The two FM broadcast segments produced show the delayed-decision technique to be virtually undegraded or minimally degraded at .001 and .01 Viterbi decoder bit error rates. Preliminary estimates of the hardware complexity of this technique indicate potential for implementation in space shuttle orbiters.

  18. Performance evaluation of image enhancement techniques on a digital image-intensifier

    NARCIS (Netherlands)

    Dijk, J.; Bijl, P.; Bouma, H.

    2009-01-01

    Recently new techniques for night-vision cameras are developed. Digital image-intensifiers are becoming available on the market. Also, so-called EMCCD cameras are developed, which may even be able to record color information about the scene. However, in low-light situations all night-vision imagery

  19. Comment on ‘A technique for image encryption using digital signature’

    Science.gov (United States)

    Hernández Encinas, L.; Peinado Domínguez, A.

    2006-12-01

    The security of a recently proposed technique for encryption images by Sinha and Singh [A. Sinha, K. Singh, Opt. Commun. 218 (2003) 229], based on the use of digital signatures and error correcting codes, is analyzed. The proposed cryptosystem is shown to have some weakness. In fact, the secret key and the original image can be recovered efficiently by a brute force attack.

  20. Digital pre-compensation techniques enabling high-capacity bandwidth variable transponders

    Science.gov (United States)

    Napoli, Antonio; Berenguer, Pablo Wilke; Rahman, Talha; Khanna, Ginni; Mezghanni, Mahdi M.; Gardian, Lennart; Riccardi, Emilio; Piat, Anna Chiadò; Calabrò, Stefano; Dris, Stefanos; Richter, André; Fischer, Johannes Karl; Sommerkorn-Krombholz, Bernd; Spinnler, Bernhard

    2018-02-01

    Digital pre-compensation techniques are among the enablers for cost-efficient high-capacity transponders. In this paper we describe various methods to mitigate the impairments introduced by state-of-the-art components within modern optical transceivers. Numerical and experimental results validate their performance and benefits.

  1. Developing a Model to Support Students in Solving Subtraction

    Directory of Open Access Journals (Sweden)

    Nila Mareta Murdiyani

    2013-01-01

    Full Text Available Subtraction has two meanings and each meaning leads to the different strategies. The meaning of “taking away something” suggests a direct subtraction, while the meaning of “determining the difference between two numbers” is more likely to be modeled as indirect addition. Many prior researches found that the second meaning and second strategy rarely appeared in the mathematical textbooks and teacher explanations, including in Indonesia. Therefore, this study was conducted to contribute to the development of a local instruction theory for subtraction by designing instructional activities that can facilitate first grade of primary school students to develop a model in solving two digit numbers subtraction. Consequently, design research was chosen as an appropriate approach for achieving the research aim and Realistic Mathematics Education (RME was used as a guide to design the lesson. This study involved 6 students in the pilot experiment, 31 students in the teaching experiment, and a first grade teacher of SDN 179 Palembang. The  result of this study shows that the beads string could bridge students from the contextual problems (taking ginger candies and making grains bracelets to the use of the empty number line. It also shows that the empty number line could promote students to  use different strategies (direct subtraction, indirect addition, and indirect subtraction in solving subtraction problems. Based on these findings, it is recommended to apply RME in the teaching learning process to make it more meaningful for students. Keywords: Subtraction, Design Research, Realistic Mathematics Education, The Beads String, The Empty Number Line DOI: http://dx.doi.org/10.22342/jme.4.1.567.95-112

  2. [Application of digital design and three-dimensional printing technique on individualized medical treatment].

    Science.gov (United States)

    Qin, Mian; Liu, Yaxiong; He, Jiankang; Wang, Ling; Lian, Qin; Li, Dichen; Jin, Zhongmin; He, Sanhu; Li, Gang; Liu, Yanpu; Wang, Zhen

    2014-03-01

    To summarize the latest research development of the application of digital design and three-dimensional (3-D) printing technique on individualized medical treatment. Recent research data and clinical literature about the application of digital design and 3-D printing technique on individualized medical treatment in Xi'an Jiaotong University and its cooperation unit were summarized, reviewed, and analyzed. Digital design and 3-D printing technique can design and manufacture individualized implant based on the patient's specific disease conditions. And the implant can satisfy the needs of specific shape and function of the patient, reducing dependence on the level of experience required for the doctor. So 3-D printing technique get more and more recognition of the surgeon on the individualized repair of human tissue. Xi'an Jiaotong University is the first unit to develop the commercial 3-D printer and conduct depth research on the design and manufacture of individualized medical implant. And complete technological processes and quality standards of product have been developed. The individualized medical implant manufactured by 3-D printing technique can not only achieve personalized match but also meet the functional requirements and aesthetic requirements of patients. In addition, the individualized medical implant has the advantages of accurate positioning, stable connection, and high strength. So 3-D printing technique has broad prospects in the manufacture and application of individualized implant.

  3. Reliability of capturing foot parameters using digital scanning and the neutral suspension casting technique

    Directory of Open Access Journals (Sweden)

    Rome Keith

    2011-03-01

    Full Text Available Abstract Background A clinical study was conducted to determine the intra and inter-rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques. Methods Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm, forefoot width (mm, rearfoot width (mm, medial arch height (mm, lateral arch height (mm and forefoot to rearfoot alignment (degrees. Intraclass correlation coefficients (ICC with 95% confidence intervals (CI were calculated to determine the intra and inter-rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM and smallest real difference (SRD. Results ICC values for all foot parameters using digital scanning ranged between 0.81-0.99 for both intra and inter-rater reliability. For neutral suspension casting technique inter-rater reliability values ranged from 0.57-0.99 and intra-rater reliability values ranging from 0.36-0.99 for rater 1 and 0.49-0.99 for rater 2. Conclusions The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting.

  4. A 3D technique for simulation of irregular electron treatment fields using a digital camera

    International Nuclear Information System (INIS)

    Bassalow, Roustem; Sidhu, Narinder P.

    2003-01-01

    Cerrobend inserts, which define electron field apertures, are manufactured at our institution using perspex templates. Contours are reproduced manually on these templates at the simulator from the field outlines drawn on the skin or mask of a patient. A previously reported technique for simulation of electron treatment fields uses a digital camera to eliminate the need for such templates. However, avoidance of the image distortions introduced by non-flat surfaces on which the electron field outlines were drawn could only be achieved by limiting the application of this technique to surfaces which were flat or near flat. We present a technique that employs a digital camera and allows simulation of electron treatment fields contoured on an anatomical surface of an arbitrary three-dimensional (3D) shape, such as that of the neck, extremities, face, or breast. The procedure is fast, accurate, and easy to perform

  5. Digital animation versus textbook in teaching plastic surgery techniques to novice learners.

    Science.gov (United States)

    Flores, Roberto L; Demoss, Patrick; Klene, Carrie; Havlik, Robert J; Tholpady, Sunil

    2013-07-01

    The authors present a prospective, randomized, blinded trial comparing the educational efficacy of digital animation versus a textbook in teaching the Ivy loop technique to novice learners. Medical student volunteers (n = 32) were anonymously videotaped as they fastened dental wire to the teeth of a skull model (preintervention analysis) and then were randomly assigned to one of two study groups. The animation and text groups (n = 16 each) were shown either a digital animation or textbook demonstrating the Ivy loop surgical technique. Volunteers were then videotaped as they performed the technique (postintervention analysis). Volunteers were then shown the educational material provided to the other study group and given a validated educational survey to compare the educational value of both materials. Preintervention and postintervention video recordings were graded using a validated surgical competency scale. Surgical performance grades, time to task completion, and educational survey scores were compared. Preintervention analysis performance scores did not significantly differ between the animation and text groups (10.7 [2.8] versus 11.1 [3.9]; p = 0.74), but postintervention analysis demonstrated significantly higher performance scores in the animation group (18.8 [2.9] versus 13.0 [3.5]; p educational survey demonstrated significantly higher scores in the animation group. A prospective, randomized, blinded study comparing the educational efficacy of a surgical textbook to digital animation demonstrates that, in novice learners, digital animation is a more effective tool for learning the Ivy loop technique. Test takers found digital animation to be the superior educational medium.

  6. Optical Measurement Techniques for Rocket Engine Testing and Component Applications: Digital Image Correlation and Dynamic Photogrammetry

    Science.gov (United States)

    Gradl, Paul

    2016-01-01

    NASA Marshall Space Flight Center (MSFC) has been advancing dynamic optical measurement systems, primarily Digital Image Correlation, for extreme environment rocket engine test applications. The Digital Image Correlation (DIC) technology is used to track local and full field deformations, displacement vectors and local and global strain measurements. This technology has been evaluated at MSFC through lab testing to full scale hotfire engine testing of the J-2X Upper Stage engine at Stennis Space Center. It has been shown to provide reliable measurement data and has replaced many traditional measurement techniques for NASA applications. NASA and AMRDEC have recently signed agreements for NASA to train and transition the technology to applications for missile and helicopter testing. This presentation will provide an overview and progression of the technology, various testing applications at NASA MSFC, overview of Army-NASA test collaborations and application lessons learned about Digital Image Correlation.

  7. Review of passive-blind detection in digital video forgery based on sensing and imaging techniques

    Science.gov (United States)

    Tao, Junjie; Jia, Lili; You, Ying

    2016-01-01

    Advances in digital video compression and IP communication technologies raised new issues and challenges concerning the integrity and authenticity of surveillance videos. It is so important that the system should ensure that once recorded, the video cannot be altered; ensuring the audit trail is intact for evidential purposes. This paper gives an overview of passive techniques of Digital Video Forensics which are based on intrinsic fingerprints inherent in digital surveillance videos. In this paper, we performed a thorough research of literatures relevant to video manipulation detection methods which accomplish blind authentications without referring to any auxiliary information. We presents review of various existing methods in literature, and much more work is needed to be done in this field of video forensics based on video data analysis and observation of the surveillance systems.

  8. Subleading power corrections for N -jettiness subtractions

    Science.gov (United States)

    Moult, Ian; Rothen, Lorena; Stewart, Iain W.; Tackmann, Frank J.; Zhu, Hua Xing

    2017-04-01

    The N -jettiness observable TN provides a way of describing the leading singular behavior of the N -jet cross section in the τ =TN/Q →0 limit, where Q is a hard interaction scale. We consider subleading-power corrections in the τ ≪1 expansion, and employ soft-collinear effective theory to obtain analytic results for the dominant αsτ ln τ and αs2τ ln3τ subleading terms for thrust in e+e- collisions and 0-jettiness for q q ¯-initiated Drell-Yan-like processes at hadron colliders. These results can be used to significantly improve the numerical accuracy and stability of the N -jettiness subtraction technique for performing fixed-order calculations at next-to-leading order and next-to-next-to-leading order. They reduce the size of missing power corrections in the subtractions by an order of magnitude. We also point out that the precise definition of N -jettiness has an important impact on the size of the power corrections and thus the numerical accuracy of the subtractions. The sometimes employed definition of N -jettiness in the hadronic center-of-mass frame suffers from power corrections that grow exponentially with rapidity, causing the power expansion to deteriorate away from central rapidity. This degradation does not occur for the original N -jettiness definition, which explicitly accounts for the boost of the Born process relative to the frame of the hadronic collision, and has a well-behaved power expansion throughout the entire phase space. Integrated over rapidity, using this N -jettiness definition in the subtractions yields another order of magnitude improvement compared to employing the hadronic-frame definition.

  9. Dental anatomy grading: comparison between conventional visual and a novel digital assessment technique.

    Science.gov (United States)

    Kwon, So Ran; Restrepo-Kennedy, Natalia; Dawson, Deborah V; Hernandez, Marcela; Denehy, Gerald; Blanchette, Derek; Gratton, David G; Aquilino, Steven A; Armstrong, Steven R

    2014-12-01

    Conventional grading of dental students' projects in preclinical courses has mainly relied on visual evaluation by experienced instructors. The purpose of this study was to compare conventional visual grading in a dental anatomy course at one U.S. dental school to a novel digital assessment technique. A total of sixty samples comprised of two sets of faculty wax-ups (n=30), student wax-ups (n=15), and dentoform teeth of tooth #14 (n=15) were used for this study. Two additional faculty members visually graded the samples according to a checklist and then repeated the grading after one week. The sample wax-up with the highest score based on the visual grading was selected as the master model for the digital grading, which was also performed twice with an interim period of one week. Descriptive statistics and signed rank tests for systematic bias were used for intra- and interrater comparisons. The intraclass correlation (ICC) was used as a measure of intra- and interrater reliability. None of the faculty members achieved the minimum acceptable intrarater agreement of 0.8. Interrater agreement was substantially less than intrarater agreement for the visual grading, whereas all measures of intrarater agreement were greater than 0.9 and considered excellent for the digital assessment technique. These results suggest that visual grading is limited by modest intrarater reliability and low interrater agreement. Digital grading is a promising evaluation method showing excellent intrarater reliability and correlation. Correlation for visual and digital grading was consistently modest, partly supporting the potential use of digital technology in dental anatomy grading.

  10. Comparison between digital subtraction angiography and magnetic resonance angiography in investigation of nonlacunar ischemic stroke in young patients: preliminary results Comparação entre arteriografia digital e angioressonância na investigação de acidente vascular cerebral isquêmico não-lacunar em pacientes jovens: resultados preliminares

    Directory of Open Access Journals (Sweden)

    Adriana Bastos Conforto

    2006-06-01

    Full Text Available PURPOSE: We preliminarily investigated the relevance of performing digital subtraction angiography (DSA in addition to magnetic resonance angiography (MRA in definition of ischemic stroke etiology in young patients. METHOD: DSAs and MRAs from 17 young patients with nonlacunar ischemic stroke were blindly analyzed and their impact on stroke management was evaluated. RESULTS: Etiologies were the same considering results of either DSA or MRA in 12/17 cases. In 15/17 patients no changes would have been made in treatment, regardless of the modality of angiography considered. CONCLUSION: These preliminary results suggest that DSA may be redundant in two thirds of ischemic strokes in young patients. Further larger prospective studies are necessary to determine indications of DSA in this age group.PROPÓSITO DO ESTUDO: Investigar de forma preliminar a relevância da realização de angiografia digital (AD adicionalmente a angioressonância (AR na definição de etiologias de acidente vascular cerebral isquêmico (AVCI em pacientes jovens. MÉTODO: ADs e ARs de 17 pacientes jovens com AVCIs não-lacunares foram analisadas. Avaliamos o impacto destes exames no manejo clínico dos casos. RESULTADOS: Em 12/17 casos, as etiologias dos AVCIs de acordo com os resultados de AD ou de AR foram idênticas. Em 15/17 pacientes, nenhuma mudança de conduta terapêutica seria realizada, independentemente da modalidade de exame considerada. CONCLUSÃO: Estes resultados preliminares sugerem que os resultados da AD podem ser redundantes em relação à AR em até dois terços dos pacientes jovens com AVCI. Estudos prospectivos maiores são necessários para otimizar o estabelecimento de indicações de AD nesta faixa etária.

  11. Reliability modeling of digital component in plant protection system with various fault-tolerant techniques

    International Nuclear Information System (INIS)

    Kim, Bo Gyung; Kang, Hyun Gook; Kim, Hee Eun; Lee, Seung Jun; Seong, Poong Hyun

    2013-01-01

    Highlights: • Integrated fault coverage is introduced for reflecting characteristics of fault-tolerant techniques in the reliability model of digital protection system in NPPs. • The integrated fault coverage considers the process of fault-tolerant techniques from detection to fail-safe generation process. • With integrated fault coverage, the unavailability of repairable component of DPS can be estimated. • The new developed reliability model can reveal the effects of fault-tolerant techniques explicitly for risk analysis. • The reliability model makes it possible to confirm changes of unavailability according to variation of diverse factors. - Abstract: With the improvement of digital technologies, digital protection system (DPS) has more multiple sophisticated fault-tolerant techniques (FTTs), in order to increase fault detection and to help the system safely perform the required functions in spite of the possible presence of faults. Fault detection coverage is vital factor of FTT in reliability. However, the fault detection coverage is insufficient to reflect the effects of various FTTs in reliability model. To reflect characteristics of FTTs in the reliability model, integrated fault coverage is introduced. The integrated fault coverage considers the process of FTT from detection to fail-safe generation process. A model has been developed to estimate the unavailability of repairable component of DPS using the integrated fault coverage. The new developed model can quantify unavailability according to a diversity of conditions. Sensitivity studies are performed to ascertain important variables which affect the integrated fault coverage and unavailability

  12. Dentists' use of digital radiographic techniques: Part I - intraoral X-ray: a questionnaire study of Swedish dentists.

    Science.gov (United States)

    Svenson, Björn; Ståhlnacke, Katri; Karlsson, Reet; Fält, Anna

    2018-03-01

    The present study aims to gain knowledge about the dentist's use and choice of digital intraoral imaging methods. A questionnaire sent to 2481 dentists within the Swedish Dental Society contained questions about the type of X-ray technique used, problems experienced with digital radiography, and reasons for choosing digital technology, and about indications, clinic size and type of service. Response rate was 53%. Ninety-eight percent of the dentists had made the transition to digital radiography; only 2% used film technique, and solid-state detector (SSD) was the most used digital technique. More years in service decreases the likelihood of applying individual indications for performing a full mouth examination. More retakes were done with SSDs compared to storage phosphor plates. Reasons for choosing digital techniques were that work was easier and communication with the patients improved. However, dentists also experienced problems with digital techniques, such as exposure and projection errors and inadequate image quality. The Swedish Radiation Safety Authority states that all radiological examinations should be justified, something not always followed. This study showed that 98% of the respondents, Swedish dentists within the Swedish Dental Society, used digital techniques, and the most used was the solid-state technique.

  13. Technology and Technique Standards for Camera-Acquired Digital Dermatologic Images: A Systematic Review.

    Science.gov (United States)

    Quigley, Elizabeth A; Tokay, Barbara A; Jewell, Sarah T; Marchetti, Michael A; Halpern, Allan C

    2015-08-01

    Photographs are invaluable dermatologic diagnostic, management, research, teaching, and documentation tools. Digital Imaging and Communications in Medicine (DICOM) standards exist for many types of digital medical images, but there are no DICOM standards for camera-acquired dermatologic images to date. To identify and describe existing or proposed technology and technique standards for camera-acquired dermatologic images in the scientific literature. Systematic searches of the PubMed, EMBASE, and Cochrane databases were performed in January 2013 using photography and digital imaging, standardization, and medical specialty and medical illustration search terms and augmented by a gray literature search of 14 websites using Google. Two reviewers independently screened titles of 7371 unique publications, followed by 3 sequential full-text reviews, leading to the selection of 49 publications with the most recent (1985-2013) or detailed description of technology or technique standards related to the acquisition or use of images of skin disease (or related conditions). No universally accepted existing technology or technique standards for camera-based digital images in dermatology were identified. Recommendations are summarized for technology imaging standards, including spatial resolution, color resolution, reproduction (magnification) ratios, postacquisition image processing, color calibration, compression, output, archiving and storage, and security during storage and transmission. Recommendations are also summarized for technique imaging standards, including environmental conditions (lighting, background, and camera position), patient pose and standard view sets, and patient consent, privacy, and confidentiality. Proposed standards for specific-use cases in total body photography, teledermatology, and dermoscopy are described. The literature is replete with descriptions of obtaining photographs of skin disease, but universal imaging standards have not been developed

  14. Digital imaging: a valuable technique for the postoperative assessment of cochlear implantation

    Energy Technology Data Exchange (ETDEWEB)

    Lawson, J.T. [Department of Radiology, Belfast City Hospital Trust, Belfast (United Kingdom); Cranley, K. [Northern Ireland Regional Medical Physics Agency, Forster Green Hospital, Belfast (United Kingdom); Toner, J.G. [Regional Cochlear Implant Centre, Belfast City Hospital Trust, Belfast (United Kingdom)

    1998-07-01

    Cochlear implantation with a multi-channel electrode array which provides stimulation via the auditory nerve has become a standard treatment for profound deafness. Postoperative radiography demonstrates electrode position and enables confirmation of satisfactory intra-cochlear electrode placement. The number of active electrodes which have been inserted can be determined and possible complications such as electrode kinking or slippage can be assessed. We evaluated digital radiography with confirmation of electrode position by intermittent fluoroscopy and assessed the relative radiation dose of the digital technique, conventional radiography and CT scanning. Radiation dose for this method usually ranges between 40 {mu}Gy and 440 {mu}Gy compared with a single exposure on the skull stand which produces a dose to the region of the cochlea of 470 {mu}Gy and a CT exposure of 950 {mu}Gy. The digital technique is comfortable for the patient, easily reproducible and provides images of high diagnostic quality enabling each electrode to be identified, which is especially valuable in association with postoperative electrode mapping. It also involves a lower radiation dose than conventional radiography. We now use digital radiography for all postoperative cochlear implant assessment. (orig.) With 4 figs., 13 refs.

  15. A Novel Digital Background Calibration Technique for 16 bit SHA-less Multibit Pipelined ADC

    Directory of Open Access Journals (Sweden)

    Swina Narula

    2016-01-01

    Full Text Available In this paper, a high resolution of 16 bit and high speed of 125MS/s, multibit Pipelined ADC with digital background calibration is presented. In order to achieve low power, SHA-less front end is used with multibit stages. The first and second stages are used here as a 3.5 bit and the stages from third to seventh are of 2.5 bit and last stage is of 3-bit flash ADC. After bit alignment and truncation of total 19 bits, 16 bits are used as final digital output. To precise the remove linear gain error of the residue amplifier and capacitor mismatching error, a digital background calibration technique is used, which is a combination of signal dependent dithering (SDD and butterfly shuffler. To improve settling time of residue amplifier, a special circuit of voltage separation is used. With the proposed digital background calibration technique, the spurious-free dynamic range (SFDR has been improved to 97.74 dB @30 MHz and 88.9 dB @150 MHz, and the signal-to-noise and distortion ratio (SNDR has been improved to 79.77 dB @ 30 MHz, and 73.5 dB @ 150 MHz. The implementation of the Pipelined ADC has been completed with technology parameters of 0.18μm CMOS process with 1.8 V supply. Total power consumption is 300 mW by the proposed ADC.

  16. Chest imaging with dual-energy substraction digital tomosynthesis

    International Nuclear Information System (INIS)

    Sone, S.; Kasuga, T.; Sakai, F.; Hirano, H.; Kubo, K.; Morimoto, M.; Takemura, K.; Hosoba, M.

    1993-01-01

    Dual-energy subtraction digital tomosynthesis with pulsed X-ray and rapid kV switching was used to examine calcifications in pulmonary lesions. The digital tomosynthesis system used included a conventional fluororadiographic TV unit with linear tomographic capabilities, a high resolution videocamera, and an image processing unit. Low-voltage, high voltage, and soft tissue subtracted or bone subtracted tomograms of any desired layer height were reconstructed from the image data acquired during a single tomographic swing. Calcifications, as well as their characteristics and distribution in pulmonary lesions, were clearly shown. The images also permitted discrimination of calcifications from dense fibrotic lesions. This technique was effective in demonstrating calcifications together with a solitary mass or disseminated nodules. (orig.)

  17. Involving elderly users in design: techniques to collect preferences for Interactive Digital Television.

    Science.gov (United States)

    Spagnolli, Anna; Gamberini, Luciano; Ibanez, Francisco; Fabregat, Maria Elena; Debelic, Tijana; Orso, Valeria

    2012-01-01

    SeniorChannel is a European project that explores the potential of using an Interactive Digital Television (IDTV) to turn elderly people at home into an active audience. Techniques to involve elderly users in the requirement collection during the design phase should take into account the decrease in perception, cognition and motor abilities associated with aging. The paper describes the specific solutions adopted here to elicit users' contribution, as well as the contributed preferences in terms of IDTV content and interaction modalities.

  18. Synchronization techniques for all digital 16-ary QAM receivers operating over land mobile satellite links

    Science.gov (United States)

    Fines, P.; Aghvami, A. H.

    1990-01-01

    The performance of a low bit rate (64 Kb/s) all digital 16-ary Differentially Encoded Quadrature Amplitude Modulation (16-DEQAM) demodulator operating over a mobile satellite channel, is considered. The synchronization and detection techniques employed to overcome the Rician channel impairments, are described. The acquisition and steady state performance of this modem, are evaluated by computer simulation over AWGN and RICIAN channels. The results verify the suitability of the 16-DEQAM transmission over slowly faded and/or mildly faded channels.

  19. Quality comparison between DEF-10 digital image from simulation technique and Computed Tomography (CR) technique in industrial radiography

    International Nuclear Information System (INIS)

    Siti Nur Syatirah Ismail

    2012-01-01

    The study was conducted to make comparison of digital image quality of DEF-10 from the techniques of simulation and computed radiography (CR). The sample used is steel DEF-10 with thickness of 15.28 mm. In this study, the sample is exposed to radiation from X-ray machine (ISOVOLT Titan E) with certain parameters. The parameters used in this study such as current, volt, exposure time and distance are specified. The current and distance of 3 mA and 700 mm respectively are specified while the applied voltage varies at 140, 160, 180 and 200 kV. The exposure time is reduced at a rate of 0, 20, 40, 60 and 80 % for each sample exposure. Digital image of simulation produced from aRTist software whereas digital image of computed radiography produced from imaging plate. Therefore, both images were compared qualitatively (sensitivity) and quantitatively (Signal to-Noise Ratio; SNR, Basic Spatial Resolution; SRb and LOP size) using Isee software. Radiographic sensitivity is indicated by Image Quality Indicator (IQI) which is the ability of the CR system and aRTist software to identify IQI of wire type when the time exposure is reduced up to 80% according to exposure chart ( D7; ISOVOLT Titan E). The image of the thinnest wire diameter achieved by radiograph from simulation and CR are the wire numbered 7 rather than the wire numbered 8 required by the standard. In quantitative comparison, this study shows that the SNR values decreases with reducing exposure time. SRb values increases for simulation and decreases for CR when the exposure time decreases and the good image quality can be achieved at 80% reduced exposure time. The high SNR and SRb values produced good image quality in CR and simulation techniques respectively. (author)

  20. Application of digital image processing techniques to faint solar flare phenomena

    Science.gov (United States)

    Glackin, D. L.; Martin, S. F.

    1980-01-01

    Digital image processing of eight solar flare events was performed using the Video Information Communication and Retrieval language in order to study moving emission fronts, flare halos, and Moreton waves. The techniques used include contrast enhancement, isointensity contouring, the differencing of images, spatial filtering, and geometrical registration. The spatial extent and temporal behavior of the faint phenomena is examined along with the relation of the three types of phenomena to one another. The image processing techniques make possible the detailed study of the history of the phenomena and provide clues to their physical nature.

  1. Application of digital image processing techniques to faint solar flare phenomena

    International Nuclear Information System (INIS)

    Glackin, D.L.; Martin, S.F.

    1980-01-01

    Digital image processing of eight solar flare events was performed using the Video Information Communication and Retrieval language in order to study moving emission fronts, flare halos, and Moreton waves. The techniques used include contrast enhancement, isointensity contouring, the differencing of images, spatial filtering, and geometrical registration. The spatial extent and temporal behavior of the faint phenomena is examined along with the relation of the three types of phenomena to one another. The image processing techniques make possible the detailed study of the history of the phenomena and provide clues to their physical nature

  2. Advanced digital modulation: Communication techniques and monolithic GaAs technology

    Science.gov (United States)

    Wilson, S. G.; Oliver, J. D., Jr.; Kot, R. C.; Richards, C. R.

    1983-01-01

    Communications theory and practice are merged with state-of-the-art technology in IC fabrication, especially monolithic GaAs technology, to examine the general feasibility of a number of advanced technology digital transmission systems. Satellite-channel models with (1) superior throughput, perhaps 2 Gbps; (2) attractive weight and cost; and (3) high RF power and spectrum efficiency are discussed. Transmission techniques possessing reasonably simple architectures capable of monolithic fabrication at high speeds were surveyed. This included a review of amplitude/phase shift keying (APSK) techniques and the continuous-phase-modulation (CPM) methods, of which MSK represents the simplest case.

  3. Seismic qualification using digital signal processing/modal testing and finite element techniques

    International Nuclear Information System (INIS)

    Steedman, J.B.; Edelstein, A.

    1983-01-01

    A systematic procedure in which digital signal processing, modal testing and finite element techniques can be used to seismically qualify Class IE equipment for use in nuclear generating stations is presented. A new method was also developed in which measured transmissibility functions and Fourier transformation techniques were combined to compute instrument response spectra. As an illustrative example of the qualification method, the paper follows the qualification of a safety related Class IE Heating, Ventilating, and Air Conditioning (HVAC) Control Panel subjected to both seismic and hydrodynamic loading conditions

  4. Simple lock-in detection technique utilizing multiple harmonics for digital PGC demodulators.

    Science.gov (United States)

    Duan, Fajie; Huang, Tingting; Jiang, Jiajia; Fu, Xiao; Ma, Ling

    2017-06-01

    A simple lock-in detection technique especially suited for digital phase-generated carrier (PGC) demodulators is proposed in this paper. It mixes the interference signal with rectangular waves whose Fourier expansions contain multiple odd or multiple even harmonics of the carrier to recover the quadrature components needed for interference phase demodulation. In this way, the use of a multiplier is avoided and the efficiency of the algorithm is improved. Noise performance with regard to light intensity variation and circuit noise is analyzed theoretically for both the proposed technique and the traditional lock-in technique, and results show that the former provides a better signal-to-noise ratio than the latter with proper modulation depth and average interference phase. Detailed simulations were conducted and the theoretical analysis was verified. A fiber-optic Michelson interferometer was constructed and the feasibility of the proposed technique is demonstrated.

  5. Improved importance sampling technique for efficient simulation of digital communication systems

    Science.gov (United States)

    Lu, Dingqing; Yao, Kung

    1988-01-01

    A new, improved importance sampling (IIS) approach to simulation is considered. Some basic concepts of IS are introduced, and detailed evolutions of simulation estimation variances for Monte Carlo (MC) and IS simulations are given. The general results obtained from these evolutions are applied to the specific previously known conventional importance sampling (CIS) technique and the new IIS technique. The derivation for a linear system with no signal random memory is considered in some detail. For the CIS technique, the optimum input scaling parameter is found, while for the IIS technique, the optimum translation parameter is found. The results are generalized to a linear system with memory and signals. Specific numerical and simulation results are given which show the advantages of CIS over MC and IIS over CIS for simulations of digital communications systems.

  6. A comparison of digital luminescence radiography and conventional film/screen techniques in the diagnosis of fractures

    International Nuclear Information System (INIS)

    Fink, U.; Schwerdtfeger, J.; Fink, B.K.; Schaetzl, M.; Reiser, M.

    1996-01-01

    The accuracy of digital luminescence radiography was compared with that of conventional film/screen techniques, using animal preparations and clinical examinations. Fine fissures were made in 8 animal bones and these were examined radiologically. The digital examinations were carried out with and without edge enhancement. 208 patients were examined in a similar way. Film quality and assessment of the fractures were evaluated quantitatively. In no instance did either of the digital methods provide inferior quality when compared with conventional films. ROC analysis for evaluation of fractures in patients, using an experienced radiologist, showed no significant difference between the various methods (ROC areas: Conventional 0.947, digital 0.958, digital with edge enhancement 0.943). With a less experienced observer there were significant advantages for both digital methods (ROC areas: 0.851, 0.886, 0.908). Our investigation has proved that fractures which are difficult to see can be reliably demonstrated by digital luminescence radiography. (orig.) [de

  7. Behavior Subtraction applied to radar

    NARCIS (Netherlands)

    Rossum, W.L. van; Caro Cuenca, M.

    2014-01-01

    An algorithm developed for optical images has been applied to radar data. The algorithm, Behavior Subtraction, is based on capturing the dynamics of a scene and detecting anomalous behavior. The radar application is the detection of small surface targets at sea. The sea surface yields the expected

  8. Color Addition and Subtraction Apps

    Science.gov (United States)

    Ruiz, Frances; Ruiz, Michael J.

    2015-01-01

    Color addition and subtraction apps in HTML5 have been developed for students as an online hands-on experience so that they can more easily master principles introduced through traditional classroom demonstrations. The evolution of the additive RGB color model is traced through the early IBM color adapters so that students can proceed step by step…

  9. Digital broadband linearization of optical links.

    Science.gov (United States)

    Lam, Daniel; Fard, Ali M; Buckley, Brandon; Jalali, Bahram

    2013-02-15

    We present a digital postprocessing linearization technique to efficiently suppress dynamic distortions added to a wideband signal in an analog optical link. Our technique achieves up to 35 dB suppression of intermodulation distortions over multiple octaves of signal bandwidth. In contrast to conventional linearization methods, it does not require excessive analog bandwidth for performing digital correction. This is made possible by regenerating undesired distortions from the captured output, and subtracting it from the distorted digitized signal. Moreover, we experimentally demonstrate a record spurious-free dynamic range of 120 dB·Hz(2/3) over a 6 GHz electrical signal bandwidth. While our digital broadband linearization technique advances state-of-the-art optical links, it can also be applied to other nonlinear dynamic systems.

  10. Study on key techniques for camera-based hydrological record image digitization

    Science.gov (United States)

    Li, Shijin; Zhan, Di; Hu, Jinlong; Gao, Xiangtao; Bo, Ping

    2015-10-01

    With the development of information technology, the digitization of scientific or engineering drawings has received more and more attention. In hydrology, meteorology, medicine and mining industry, the grid drawing sheet is commonly used to record the observations from sensors. However, these paper drawings may be destroyed and contaminated due to improper preservation or overuse. Further, it will be a heavy workload and prone to error if these data are manually transcripted into the computer. Hence, in order to digitize these drawings, establishing the corresponding data base will ensure the integrity of data and provide invaluable information for further research. This paper presents an automatic system for hydrological record image digitization, which consists of three key techniques, i.e., image segmentation, intersection point localization and distortion rectification. First, a novel approach to the binarization of the curves and grids in the water level sheet image has been proposed, which is based on the fusion of gradient and color information adaptively. Second, a fast search strategy for cross point location is invented and point-by-point processing is thus avoided, with the help of grid distribution information. And finally, we put forward a local rectification method through analyzing the central portions of the image and utilizing the domain knowledge of hydrology. The processing speed is accelerated, while the accuracy is still satisfying. Experiments on several real water level records show that our proposed techniques are effective and capable of recovering the hydrological observations accurately.

  11. Theoretical characterization of performance effectiveness of photon-counting technique for digital radiography applications

    Science.gov (United States)

    Yun, Seungman; Kim, Jaehyuk; Huh, Yoonsuk; Kim, Jungha; Park, Sujin; Kim, Jungmin; Kim, Jongpil; Yoon, Kyung Hun; Jo, JaeMoon

    2017-03-01

    Photon-counting (PC) technique has been paid attention to digital radiography applications due to its potential in lowdose operation and multi-energy imaging capability. In this study, we theoretically investigate the performance gain in digital radiography when the PC detectors are used instead of the conventional energy-integrating (EI) detectors. We use the Monte Carlo technique for estimating energy-absorption distributions in detector materials such as CdTe for the PC detector and CsI for the EI detector. To estimate the signal and noise transfers through the two different detectoroperation schemes, we use the cascaded linear-systems approach. In the Monte Carlo simulations, the square and rectangle focal spots are considered to mimic the advanced carbon nanotube (CNT) and conventional filament cathodes, respectively. From the simulation results, the modulation-transfer functions of the PC detector are more sensitive to asymmetric focal spot geometry than those of the EI detector. On the other hand, the PC detector shows better image signal-to-noise ratio than the EI detector; hence better dose efficiency with the PC detector. The dose efficiency of the PC detector in comparison with the EI detector is however marginal for the filament x-ray beam whereas the dose efficiency is not negligible for the CNT x-ray beam. The theoretical upper limits of the imaging performance of the advanced digital radiography technology are reported in this study.

  12. High-Speed Photography and Digital Optical Measurement Techniques for Geomaterials: Fundamentals and Applications

    Science.gov (United States)

    Xing, H. Z.; Zhang, Q. B.; Braithwaite, C. H.; Pan, B.; Zhao, J.

    2017-06-01

    Geomaterials (i.e. rock, sand, soil and concrete) are increasingly being encountered and used in extreme environments, in terms of the pressure magnitude and the loading rate. Advancing the understanding of the mechanical response of materials to impact loading relies heavily on having suitable high-speed diagnostics. One such diagnostic is high-speed photography, which combined with a variety of digital optical measurement techniques can provide detailed insights into phenomena including fracture, impact, fragmentation and penetration in geological materials. This review begins with a brief history of high-speed imaging. Section 2 discusses of the current state of the art of high-speed cameras, which includes a comparison between charge-coupled device and complementary metal-oxide semiconductor sensors. The application of high-speed photography to geomechanical experiments is summarized in Sect. 3. Section 4 is concerned with digital optical measurement techniques including photoelastic coating, Moiré, caustics, holographic interferometry, particle image velocimetry, digital image correlation and infrared thermography, in combination with high-speed photography to capture transient phenomena. The last section provides a brief summary and discussion of future directions in the field.

  13. Taking stock of the toolkit: an overview of relevant automated content analysis approaches and techniques for digital journalism scholars

    NARCIS (Netherlands)

    Boumans, J.W.; Trilling, D.

    2016-01-01

    When analyzing digital journalism content, journalism scholars are confronted with a number of substantial differences compared to traditional journalistic content. The sheer amount of data and the unique features of digital content call for the application of valuable new techniques. Various other

  14. B-spline design of digital FIR filter using evolutionary computation techniques

    Science.gov (United States)

    Swain, Manorama; Panda, Rutuparna

    2011-10-01

    In the forth coming era, digital filters are becoming a true replacement for the analog filter designs. Here in this paper we examine a design method for FIR filter using global search optimization techniques known as Evolutionary computation via genetic algorithm and bacterial foraging, where the filter design considered as an optimization problem. In this paper, an effort is made to design the maximally flat filters using generalized B-spline window. The key to our success is the fact that the bandwidth of the filer response can be modified by changing tuning parameters incorporated well within the B-spline function. This is an optimization problem. Direct approach has been deployed to design B-spline window based FIR digital filters. Four parameters (order, width, length and tuning parameter) have been optimized by using GA and EBFS. It is observed that the desired response can be obtained with lower order FIR filters with optimal width and tuning parameters.

  15. Recent developments at JPL in the application of digital image processing techniques to astronomical images

    Science.gov (United States)

    Lorre, J. J.; Lynn, D. J.; Benton, W. D.

    1976-01-01

    Several techniques of a digital image-processing nature are illustrated which have proved useful in visual analysis of astronomical pictorial data. Processed digital scans of photographic plates of Stephans Quintet and NGC 4151 are used as examples to show how faint nebulosity is enhanced by high-pass filtering, how foreground stars are suppressed by linear interpolation, and how relative color differences between two images recorded on plates with different spectral sensitivities can be revealed by generating ratio images. Analyses are outlined which are intended to compensate partially for the blurring effects of the atmosphere on images of Stephans Quintet and to obtain more detailed information about Saturn's ring structure from low- and high-resolution scans of the planet and its ring system. The employment of a correlation picture to determine the tilt angle of an average spectral line in a low-quality spectrum is demonstrated for a section of the spectrum of Uranus.

  16. A technique for recovering nonsynchronized data from a digital flight data recorder

    Science.gov (United States)

    Roberts, C. A.

    1980-06-01

    How critical data in out-of-synch areas of a digital flight data recorder tape can be recovered using a serial binary technique called BITDUMP is explained. Digital flight data recorder data recovery depends on the acquisition of a synchronization word once every second. Critical synchronization timing is interrupted if tape motion becomes unsteady or if the tape breaks on impact in an aircraft accident. Several cases where synchronization of critical data was lost because of tape breakage, as in the American Airlines DC-10 accident at Chicago, Illinois, on May 25, 1979 and the Air New Zealand DC-10 accident in Antarctica on 28 November 1979 are cited. The American Airlines DC-10 accident is analyzed in detail to demonstrate BITDUMP application.

  17. Digital image processing techniques for detecting, quantifying and classifying plant diseases.

    Science.gov (United States)

    Arnal Barbedo, Jayme Garcia

    2013-12-07

    This paper presents a survey on methods that use digital image processing techniques to detect, quantify and classify plant diseases from digital images in the visible spectrum. Although disease symptoms can manifest in any part of the plant, only methods that explore visible symptoms in leaves and stems were considered. This was done for two main reasons: to limit the length of the paper and because methods dealing with roots, seeds and fruits have some peculiarities that would warrant a specific survey. The selected proposals are divided into three classes according to their objective: detection, severity quantification, and classification. Each of those classes, in turn, are subdivided according to the main technical solution used in the algorithm. This paper is expected to be useful to researchers working both on vegetable pathology and pattern recognition, providing a comprehensive and accessible overview of this important field of research.

  18. Aluminum Gallium Nitride Alloys Grown via Metalorganic Vapor-Phase Epitaxy Using a Digital Growth Technique

    Science.gov (United States)

    Rodak, L. E.; Korakakis, D.

    2011-04-01

    This work investigates the use of a digital growth technique as a viable method for achieving high-quality aluminum gallium nitride (Al x Ga1- x N) films via metalorganic vapor-phase epitaxy. Digital alloys are superlattice structures with period thicknesses of a few monolayers. Alloys with an AlN mole fraction ranging from 0.1 to 0.9 were grown by adjusting the thickness of the AlN layer in the superlattice. High-resolution x-ray diffraction was used to determine the superlattice period and c-lattice parameter of the structure, while reciprocal-space mapping was used to determine the a-lattice parameter and evaluate growth coherency. A comparison of the measured lattice parameter with both the nominal value and also the underlying buffer layer is discussed.

  19. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Engesaeter, Ingvild Oevsteboe [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Haukeland University Hospital, The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Bergen (Norway); Laborie, Lene Bjerke; Rosendahl, Karen [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Lehmann, Trude Gundersen; Fevang, Jonas; Engesaeter, Lars Birger [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Sera, Francesco [University College London Institute of Child Health, Medical Research Council Centre of Epidemiology for Child Health, London (United Kingdom); Pedersen, Douglas; Morcuende, Jose [University of Iowa Hospital and Clinics, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); Lie, Stein Atle [Uni Health, Uni Research, Bergen (Norway)

    2012-07-15

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Toennis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good. (orig.)

  20. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    International Nuclear Information System (INIS)

    Axelsson, B.; Hansson, I.B.; Boden, K.; Witt, H.H.; Fransson, S.G.; Persliden, J.

    2000-01-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm 2 ) for the fully digital technique compared to the others (analogue 6.8 Gycm 2 , analogue+digital 3.6 Gycm 2 ). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  1. A simple infrared-augmented digital photography technique for detection of pupillary abnormalities.

    Science.gov (United States)

    Shazly, Tarek A; Bonhomme, G R

    2015-03-01

    The purpose of the study was to describe a simple infrared photography technique to aid in the diagnosis and documentation of pupillary abnormalities. An unmodified 12-megapixel "point and shoot" digital camera was used to obtain binocular still photos and videos under different light conditions with near-infrared illuminating frames. The near-infrared light of 850 nm allows the capture of clear pupil images in both dim and bright light conditions. It also allows easy visualization of the pupil despite pigmented irides by augmenting the contrast between the iris and the pupil. The photos and videos obtained illustrated a variety of pupillary abnormalities using the aforementioned technique. This infrared-augmented photography technique supplements medical education, and aids in the more rapid detection, diagnosis, and documentation of a wide spectrum of pupillary abnormalities. Its portability and ease of use with minimal training complements the education of trainees and facilitates the establishment of difficult diagnoses.

  2. The digital geometric phase technique applied to the deformation evaluation of MEMS devices

    International Nuclear Information System (INIS)

    Liu, Z W; Xie, H M; Gu, C Z; Meng, Y G

    2009-01-01

    Quantitative evaluation of the structure deformation of microfabricated electromechanical systems is of importance for the design and functional control of microsystems. In this investigation, a novel digital geometric phase technique was developed to meet the deformation evaluation requirement of microelectromechanical systems (MEMS). The technique is performed on the basis of regular artificial lattices, instead of a natural atom lattice. The regular artificial lattices with a pitch ranging from micrometer to nanometer will be directly fabricated on the measured surface of MEMS devices by using a focused ion beam (FIB). Phase information can be obtained from the Bragg filtered images after fast Fourier transform (FFT) and inverse fast Fourier transform (IFFT) of the scanning electronic microscope (SEM) images. Then the in-plane displacement field and the local strain field related to the phase information will be evaluated. The obtained results show that the technique can be well applied to deformation measurement with nanometer sensitivity and stiction force estimation of a MEMS device

  3. Techniques for transmitting digital data on the Spacelab's analog video channel

    Science.gov (United States)

    Smith, Dean L.; Hanby, Walter D.

    1993-01-01

    A study was made of various techniques for transmitting digital data over a composite video channel. Transmitting data from experiments on the Space Shuttle Orbiter over a video channel is attractive since extra channel capacity is needed. Broadcast television telecommunications schemes and other techniques described in the literature were reviewed and compared. PSK (Phase Shift Keying), MPSK (m-ary PSK), or PAM (Pulse Amplitude Modulation) can be transmitted on visible lines of a frame, unassigned lines of the VBI (Vertical Blanking Interval), or during the HBI (Horizontal Blanking Interval). All three modulation techniques can be attractive under the proper conditions. However, PAM on visible lines or during the VBI should be relatively easy to implement, provide adequate average data rates, and give acceptable BERs (Bit Error Rates).

  4. Recognition of landforms from digital elevation models and satellite imagery with expert systems, pattern recognition and image processing techniques

    OpenAIRE

    Miliaresis, George

    2014-01-01

    Recognition of landforms from digital elevation models and satellite imagery with expert systems, pattern recognition and image processing techniques. PhD Thesis, Remote Sensing & Terrain Pattern Recognition),National Technical University of Athens, Dpt. of Topography (2000).

  5. A New Algorithm for the Subtraction Games

    OpenAIRE

    He, Guanglei; Qin, Zhihui

    2012-01-01

    Subtraction games is a class of combinatorial games. It was solved since the Sprague-Grundy Theory was put forward. This paper described a new algorithm for subtraction games. The new algorithm can find win or lost positions in subtraction games. In addition, it is much simpler than Sprague-Grundy Theory in one pile of the games.

  6. Development of a fully automated adaptive unsharp masking technique in digital chest radiograph

    International Nuclear Information System (INIS)

    Abe, Katsumi; Katsuragawa, Shigehiko; Sasaki, Yasuo

    1991-01-01

    We are developing a fully automated adaptive unsharp masking technique with various parameters depending on regional image features of a digital chest radiograph. A chest radiograph includes various regions such as lung fields, retrocardiac area and spine in which their texture patterns and optical densities are extremely different. Therefore, it is necessary to enhance image contrast of each region by each optimum parameter. First, we investigated optimum weighting factors and mask sizes of unsharp masking technique in a digital chest radiograph. Then, a chest radiograph is automatically divided into three segments, one for the lung field, one for the retrocardiac area, and one for the spine, by using histogram analysis of pixel values. Finally, high frequency components of the lung field and retrocardiac area are selectively enhanced with a small mask size and mild weighting factors which are previously determined as optimum parameters. In addition, low frequency components of the spine are enhanced with a large mask size and adequate weighting factors. This processed image shows excellent depiction of the lung field, retrocardiac area and spine simultaneously with optimum contrast. Our image processing technique may be useful for diagnosis of chest radiographs. (author)

  7. Applications of digital image processing techniques to problems of data registration and correlation

    Science.gov (United States)

    Green, W. B.

    1978-01-01

    An overview is presented of the evolution of the computer configuration at JPL's Image Processing Laboratory (IPL). The development of techniques for the geometric transformation of digital imagery is discussed and consideration is given to automated and semiautomated image registration, and the registration of imaging and nonimaging data. The increasing complexity of image processing tasks at IPL is illustrated with examples of various applications from the planetary program and earth resources activities. It is noted that the registration of existing geocoded data bases with Landsat imagery will continue to be important if the Landsat data is to be of genuine use to the user community.

  8. Simulation and analysis of natural rain in a wind tunnel via digital image processing techniques

    Science.gov (United States)

    Aaron, K. M.; Hernan, M.; Parikh, P.; Sarohia, V.; Gharib, M.

    1986-01-01

    It is desired to simulate natural rain in a wind tunnel in order to investigate its influence on the aerodynamic characteristics of aircraft. Rain simulation nozzles have been developed and tested at JPL. Pulsed laser sheet illumination is used to photograph the droplets in the moving airstream. Digital image processing techniques are applied to these photographs for calculation of rain statistics to evaluate the performance of the nozzles. It is found that fixed hypodermic type nozzles inject too much water to simulate natural rain conditions. A modification uses two aerodynamic spinners to flex a tube in a pseudo-random fashion to distribute the water over a larger area.

  9. An automatic regulating control system for a graphite moderated reactor using digital techniques

    International Nuclear Information System (INIS)

    Carvalho Goncalves Junior, J. de.

    1989-01-01

    The work propose an automatic regulating control system for a graphite moderated reactor using digital techniques. The system uses a microcomputer to monitor the power and the period, to run the control algorithm, and to generate electronic signals to excite the motor, which moves vertically the control rod banks. A nuclear reactor simulator was developed to test the control system. The simulator consists of a software based on the point kinetic equations and implanted in an analogical computer. The results show that this control system has a good performance and versatility. In addition, the simulator is capable of reproducing with accuracy the behavior of a nuclear reactor. (author)

  10. Graphical Evaluation of Time-Delay Compensation Techniques for Digitally Controlled Converters

    DEFF Research Database (Denmark)

    Lu, Minghui; Wang, Xiongfei; Loh, Poh Chiang

    2018-01-01

    A main design constraint of the digitally controlled power electronics converters is the time delay of control systems, which may lead to the reduced control loop bandwidth and even unstable dynamics. Numerous time-delay compensation methods have been developed, of which the model-free schemes...... are independent to model accuracy whereas the model-based alternatives are sensitive to system modeling. This paper first presents a graphical illustration of four model-free delay compensation techniques, where their principles and performances are intuitively elaborated and compared by means of the impulse area....... Simulations and experimental test results validate the effectiveness of the graphical comparisons and the proposed approach....

  11. Optimal space communications techniques. [using digital and phase locked systems for signal processing

    Science.gov (United States)

    Schilling, D. L.

    1974-01-01

    Digital multiplication of two waveforms using delta modulation (DM) is discussed. It is shown that while conventional multiplication of two N bit words requires N2 complexity, multiplication using DM requires complexity which increases linearly with N. Bounds on the signal-to-quantization noise ratio (SNR) resulting from this multiplication are determined and compared with the SNR obtained using standard multiplication techniques. The phase locked loop (PLL) system, consisting of a phase detector, voltage controlled oscillator, and a linear loop filter, is discussed in terms of its design and system advantages. Areas requiring further research are identified.

  12. 100 ways to make good photos great tips & techniques for improving your digital photography

    CERN Document Server

    Cope, Peter

    2013-01-01

    A practical, accessible guide to turning your good photographs into great ones whether you are shooting on the latest digital SLR or a camera phone! Discover 100 simple and fun ways to improve your photographs both in-camera and through post-processing image manipulation. Every key photographic genre is covered, from perfect portraits and the great outdoors, to travel photos and shooting at night. Filled with inspirational examples of great photographs compared against the more average images, with easy to follow techniques for how you can achieve the same results.

  13. A proposed security technique based on watermarking and encryption for digital imaging and communications in medicine

    Directory of Open Access Journals (Sweden)

    Mohamed M. Abd-Eldayem

    2013-03-01

    Full Text Available Nowadays; modern Hospital Data Management Systems (HDMSs are applied in a computer network; in addition medicinal equipments produce medical images in a digital form. HDMS must store and exchange these images in a secured environment to provide image integrity and patient privacy. The reversible watermarking techniques can be used to provide the integrity and the privacy. In this paper, a security technique based on watermarking and encryption is proposed to be used for Digital Imaging and Communications in Medicine (DICOM. It provides patient authentication, information confidentiality and integrity based on reversible watermark. To achieve integrity service at the sender side; a hash value based on encrypted MD5 is determined from the image. And to satisfy the reversible feature; R–S-Vector is determined from the image and is compressed based on a Huffman compression algorithm. After that to provide confidentiality and authentication services: the compressed R–S-Vector, the hash value and patient ID are concatenated to form a watermark then this watermark is encrypted using AES encryption technique, finally the watermark is embedded inside the medical image. Experimental results prove that the proposed technique can provide patient authentication services, image integrity service and information confidentiality service with excellent efficiency. Concluded results for all tested DICOM medical images and natural images show the following: BER equals 0, both of SNR and PSNR are consistent and have large values, and MSE has low value; the average values of SNR, PSNR and MSE are 52 dB, 57 dB and 0.12 respectively. Therefore, watermarked images have high imperceptibility, invisibility and transparency. In addition, the watermark extracted from the image at the receiver side is identical to the watermark embedded into the image in the sender side; as a result, the proposed technique is totally reversible, and the embedded watermark does not

  14. Digital Collections Are a Sprint, Not a Marathon: Adapting Scrum Project Management Techniques to Library Digital Initiatives

    Directory of Open Access Journals (Sweden)

    Michael Dulock

    2015-12-01

    Full Text Available This article describes a case study in which a small team from the digital initiatives group and metadata services department at the University of Colorado Boulder (CU-Boulder Libraries conducted a pilot of the Scrum project management framework. The pilot team organized digital initiatives work into short, fixed intervals called sprints—a key component of Scrum. Over a year of working in the modified framework yielded significant improvements to digital collection work, including increased production of digital objects and surrogate records, accelerated publication of digital collections, and an increase in the number of concurrent projects. Adoption of sprints has improved communication and cooperation among participants, reinforced teamwork, and enhanced their ability to adapt to shifting priorities.

  15. Computerized detection of mass lesions in digital mammograms

    International Nuclear Information System (INIS)

    Yin, F.F.; Giger, M.L.; Doi, K.; Metz, C.E.; Vyborny, C.J.; Schmidt, R.A.

    1989-01-01

    Early detection of breast cancer from the periodic screening of asymptomatic women could reduce breast cancer mortality by at least 40%. The authors are developing a computerized scheme for the detection of mass lesions in digital mammograms as an aid to radiologists in such high volume screening programs. Based on left-right architectural symmetry and gray-level histogram analysis, bilateral subtraction of left and right breast images is performed. False-positive detections included in bilateral-difference images are reduced with various images feature-extraction techniques. The database involves clinical film mammograms digitized by a TV camera and analyzed on a Micro-VAX workstation. Among five different bilateral subtraction techniques investigated, a nonlinear approach provided superior lesion enhancement. Feature-extraction techniques reduced substantially the remaining false-positives. Preliminary results, for 32 pairs of clinical mammograms, yielded a true-positive rate of approximately 95% with a false-positive rate of about 2 per image

  16. Usefulness of dynamic subtraction CT for intracranial high density lesions

    Energy Technology Data Exchange (ETDEWEB)

    Takagi, Ryo; Hayashi, Hiromitsu; Ichikawa, Taro; Kumazaki, Tatsuo (Nippon Medical School, Tokyo (Japan))

    1994-04-01

    Dynamic subtraction CT (DSCT) using a high speed Rotate/Rotate CT Scanner (Toshiba Xforce) was performed on 10 patients with intracranial high density lesions such as brain tumors and vascular malformations. In comparison with conventional contrast enhanced CT, the technique of dynamic subtraction CT enabled us to evaluate more clearly the contrast enhancement of high density lesions and to separate more easily the lesions from hematoma and calcification, which are shown as avascular areas. The results suggest that DSCT is a valuable method for evaluating the contrast enhancement of intracranial high density lesions. (author).

  17. Absolute quantification of Bovine Viral Diarrhea Virus (BVDV) RNA by the digital PCR technique

    International Nuclear Information System (INIS)

    Flatschart, R B; Almeida, D O; Medeiros, M N; Granjeiro, J M; Folgueras-Flatschart, A V; Heinemann, M B

    2015-01-01

    The quality control of cell lines used in research and industry is critical to ensure confidence in experimental results and to guarantee the safety of biopharmaceuticals to consumers. The BVDV is a common adventitious agent in many cell lines. We preliminarly evaluate the use of Digital Droplet PCR (ddPCR) for the detection and enumeration of genome copies of BVDV in cell culture and on FBS. The application of a commercial Real-Time PCR kit with the ddPCR technique was successful on different matrices. The technique allowed the absolute quantification of the genome without the use of calibration standards, suggesting its promising application on the development of reference materials for quantification of nucleic acids

  18. Absolute quantification of Bovine Viral Diarrhea Virus (BVDV) RNA by the digital PCR technique

    Science.gov (United States)

    Flatschart, R. B.; Almeida, D. O.; Heinemann, M. B.; Medeiros, M. N.; Granjeiro, J. M.; Folgueras-Flatschart, A. V.

    2015-01-01

    The quality control of cell lines used in research and industry is critical to ensure confidence in experimental results and to guarantee the safety of biopharmaceuticals to consumers. The BVDV is a common adventitious agent in many cell lines. We preliminarly evaluate the use of Digital Droplet PCR (ddPCR) for the detection and enumeration of genome copies of BVDV in cell culture and on FBS. The application of a commercial Real-Time PCR kit with the ddPCR technique was successful on different matrices. The technique allowed the absolute quantification of the genome without the use of calibration standards, suggesting its promising application on the development of reference materials for quantification of nucleic acids.

  19. Comparison between Two Digital Panoramic Radiography Techniques for Proximal Caries Detection

    Directory of Open Access Journals (Sweden)

    Mina Shafagh Motlagh

    2013-03-01

    Full Text Available Introduction: Although proximal dental caries are very common, clinical examinations cannot detect them all. Panoramic radiography has been widely used in dentistry for both diagnosis and screening. This study aimed to investigate and compare the efficacy of two digital panoramic radiography techniques in the diagnosis of proximal caries. Methods: A total number of 60 patients referred to a dental radiology center, all had complete dental system and bitewing radiographies, were included. The patients were randomly divided into two groups of 30 patients. For the first and second groups, CR and DR images were obtained respectively. Images were obtained from the distal of the third tooth to the distal of the eighth. Bitewing images were compared with CR and DR images regarding the detection of caries. Kappa index and chi-squared statistics were employed to analyze the results. Results: There was a high agreement rate between bitewing images and CR (Kappa=0.775 and DR (Kappa=o.762 images in detecting caries. Also no significant difference was shown between CR and DR techniques in the detection of caries (0.543. However, DR and CR images are not efficient enough to be prescribed as the sole imaging technique to detect proximal caries. Conclusion: DR and CR techniques could be good imaging techniques for the detection of dental caries as a companion to clinical examinations.

  20. The Comparison between Two Different Digital Panoramic Radiography Techniques in the Detection of Proximal Caries

    Directory of Open Access Journals (Sweden)

    Hossein Hoseini Zarch

    2013-03-01

    Full Text Available Introduction: Although proximal dental caries are very common, clinical examinations cannot detect them all. Panoramic radiography has been widely used in dentistry for both diagnosis and screening. This study aimed to investigate and compare the efficacy of two digital panoramic radiography techniques in the diagnosis of proximal caries. Methods: A total number of 60 patients referred to a dental radiology center, all had complete dental system and bitewing radiographies, were included. The patients were randomly divided into two groups of 30 patients. For the first and second groups, CR and DR images were obtained respectively. Images were obtained from the distal of the third tooth to the distal of the eighth. Bitewing images were compared with CR and DR images regarding the detection of caries. Kappa index and chi-squared statistics were employed to analyze the results. Results: There was a high agreement rate between bitewing images and CR (Kappa=0.775 and DR (Kappa=o.762 images in detecting caries. Also no significant difference was shown between CR and DR techniques in the detection of caries (0.543. However, DR and CR images are not efficient enough to be prescribed as the sole imaging technique to detect proximal caries. Conclusion: DR and CR techniques could be good imaging techniques for the detection of dental caries as a companion to clinical examinations

  1. The Art of Hardware Architecture Design Methods and Techniques for Digital Circuits

    CERN Document Server

    Arora, Mohit

    2012-01-01

    This book highlights the complex issues, tasks and skills that must be mastered by an IP designer, in order to design an optimized and robust digital circuit to solve a problem. The techniques and methodologies described can serve as a bridge between specifications that are known to the designer and RTL code that is final outcome, reducing significantly the time it takes to convert initial ideas and concepts into right-first-time silicon.� Coverage focuses on real problems rather than theoretical concepts, with an emphasis on design techniques across various aspects of chip-design.�� Describes techniques to help IP designers get it right the first time, creating designs optimized in terms of power, area and performance; Focuses on practical aspects of chip design and minimizes theory; Covers chip design in a consistent way, starting with basics and gradually developing advanced concepts, such as electromagnetic compatibility (EMC) design techniques and low-power design techniques such as dynamic voltage...

  2. UV Digital Imaging of Sulfur Dioxide Emissions: Enhancing the Technique With Empirical Corrections

    Science.gov (United States)

    Dalton, M. P.; Bluth, G. J.; Shannon, J. M.; Watson, I. M.

    2006-12-01

    SO2 emission measurements are an important component of monitoring volcanic processes, providing insight into the driving forces behind eruptions. Current spectrometric methods (COSPEC, DOAS) typically measure only a cross-section of the plume, which may not be representative of the actual emission flux, and coupled with the difficulty in determining wind speeds affecting the air mass, often leads to erratic SO2 flux values. In order to address these problems, we have developed a ground-based ultraviolet digital camera for the imaging and measurement of SO2 volcanic plumes. This camera improves on the spectrometric methods of SO2 observation by capturing a large portion of the plume in one measurement- a single image. The UV digital camera can also record multiple images every minute, producing a data set that is more comparable with other monitoring techniques. The UV digital camera has proven capable of imaging volcanic plumes under fairly demanding conditions, and determining SO2 fluxes that have roughly agreed with other SO2 measurement techniques. Initial field tests suggest that the data produced by the UV camera are significantly affected by atmospheric scattering. To better evaluate the errors and limitations associated with this new instrument, field experiments have been conducted to assess the effects that background sky brightness, meteorological conditions, and distance to the target have on the calculated SO2 concentrations and flux measurements. Our results will allow us to more accurately model and correct for changing atmospheric conditions and quantify the error associated with atmospheric background scattering. These corrections will make this remarkable new instrument a more accurate and valuable tool for monitoring volcanic emissions.

  3. Using digital filtering techniques as an aid in wind turbine data analysis

    Energy Technology Data Exchange (ETDEWEB)

    Young, T. [Univ. of Colorado, Boulder, CO (United States). BioServe Space Technologies

    1994-11-01

    Research involving very large sets of digital data is often difficult due to the enormity of the database. In the case of a wind turbine operating under varying environmental conditions, determining which data are representative of the blade aerodynamics and which are due to transient flow ingestion effects or errors in instrumentation, operation, and data collection is of primary concern to researchers. The National Renewable Energy Laboratory in Golden, Colorado collected extensive data on a downwind horizontal axis wind turbine (HAWT) during a turbine test project called the Combined Experiment. A principal objective of this experiment was to provide a means to predict HAWT aerodynamic, mechanical, and electrical operational loads based upon analytical models of aerodynamic performance related to blade design and inflow conditions. In a collaborative effort with the Aerospace Engineering Department at the University of Colorado at Boulder, a team of researchers has evolved and utilized various digital filtering techniques in analyzing the data from the Combined Experiment. A preliminary analysis of the data set was performed to determine how to best approach the data. The reduced data set emphasized selection of inflow conditions such that the aerodynamic data could be compared directly to wind tunnel data obtained for the same airfoil design as used for the HAWT`s blades. It will be shown that this reduced data set has yielded valid, reproducible results that a simple averaging technique or a random selection approach cannot achieve. These findings provide a stable baseline against which operational HAWT data can be compared.

  4. Digital image analysis in breast pathology-from image processing techniques to artificial intelligence.

    Science.gov (United States)

    Robertson, Stephanie; Azizpour, Hossein; Smith, Kevin; Hartman, Johan

    2018-04-01

    Breast cancer is the most common malignant disease in women worldwide. In recent decades, earlier diagnosis and better adjuvant therapy have substantially improved patient outcome. Diagnosis by histopathology has proven to be instrumental to guide breast cancer treatment, but new challenges have emerged as our increasing understanding of cancer over the years has revealed its complex nature. As patient demand for personalized breast cancer therapy grows, we face an urgent need for more precise biomarker assessment and more accurate histopathologic breast cancer diagnosis to make better therapy decisions. The digitization of pathology data has opened the door to faster, more reproducible, and more precise diagnoses through computerized image analysis. Software to assist diagnostic breast pathology through image processing techniques have been around for years. But recent breakthroughs in artificial intelligence (AI) promise to fundamentally change the way we detect and treat breast cancer in the near future. Machine learning, a subfield of AI that applies statistical methods to learn from data, has seen an explosion of interest in recent years because of its ability to recognize patterns in data with less need for human instruction. One technique in particular, known as deep learning, has produced groundbreaking results in many important problems including image classification and speech recognition. In this review, we will cover the use of AI and deep learning in diagnostic breast pathology, and other recent developments in digital image analysis. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Digital implementation of a laser frequency stabilisation technique in the telecommunications band

    Science.gov (United States)

    Jivan, Pritesh; van Brakel, Adriaan; Manuel, Rodolfo Martínez; Grobler, Michael

    2016-02-01

    Laser frequency stabilisation in the telecommunications band was realised using the Pound-Drever-Hall (PDH) error signal. The transmission spectrum of the Fabry-Perot cavity was used as opposed to the traditionally used reflected spectrum. A comparison was done using an analogue as well as a digitally implemented system. This study forms part of an initial step towards developing a portable optical time and frequency standard. The frequency discriminator used in the experimental setup was a fibre-based Fabry-Perot etalon. The phase sensitive system made use of the optical heterodyne technique to detect changes in the phase of the system. A lock-in amplifier was used to filter and mix the input signals to generate the error signal. This error signal may then be used to generate a control signal via a PID controller. An error signal was realised at a wavelength of 1556 nm which correlates to an optical frequency of 1.926 THz. An implementation of the analogue PDH technique yielded an error signal with a bandwidth of 6.134 GHz, while a digital implementation yielded a bandwidth of 5.774 GHz.

  6. In vitro evaluation of prosthodontic impression on natural dentition: a comparison between traditional and digital techniques

    Science.gov (United States)

    MALAGUTI, G.; ROSSI, R.; MARZIALI, B.; ESPOSITO, A.; BRUNO, G.; DARIOL, C.; DI FIORE, A.

    2016-01-01

    SUMMARY Objectives The aim of this in vitro study is to evaluate the marginal and internal fit of zirconia core crowns manufactured following different digital and traditional workflows. Methods A 6° taper shoulder prepared abutment tooth was used to produce 20 zirconia core crowns using four different scanning techniques: scanned directly with the extraoral lab scanner, scanned with intraoral scanner, dental impressions using individual dental tray and polyether, dental casts from a polyether impressions. Marginal and internal fits were evaluated with digital photography and the silicone replica method. Results Medium marginal gaps were 76,00 μm ± 28.9 for extraoral lab scanner, 80.50 μm ± 36,2 for intraoral scanner, 88.10 μm ± 34,8 for dental impression scan and 112,4 μm ± 37,2 for dental cast scan. Medium internal gaps were 23.20 μm ± 10,3 for extraoral lab scanner, 16.20 μm ± 8.3 for intraoral scanner, 27.20 μm ± 16.7 for dental impression scan and 30.20 μm ± 12.7 for dental cast scan. Conclusion Internal gap were extensively lower than 70 μm described in literature. Marginal fit was higher than ideal values for all the techniques but within the limit of clinical success. Intraoral scanners obtained the best results for internal gap. PMID:28280529

  7. Digital filtering techniques applied to electric power systems protection; Tecnicas de filtragem digital aplicadas a protecao de sistemas eletricos de potencia

    Energy Technology Data Exchange (ETDEWEB)

    Brito, Helio Glauco Ferreira

    1996-12-31

    This work introduces an analysis and a comparative study of some of the techniques for digital filtering of the voltage and current waveforms from faulted transmission lines. This study is of fundamental importance for the development of algorithms applied to digital protection of electric power systems. The techniques studied are based on the Discrete Fourier Transform theory, the Walsh functions and the Kalman filter theory. Two aspects were emphasized in this study: Firstly, the non-recursive techniques were analysed with the implementation of filters based on Fourier theory and the Walsh functions. Secondly, recursive techniques were analyzed, with the implementation of the filters based on the Kalman theory and once more on the Fourier theory. (author) 56 refs., 25 figs., 16 tabs.

  8. X-ray film digitization using a personal computer and hand-held scanner: a simple technique for storing images

    International Nuclear Information System (INIS)

    Munoz-Nunez, C. F.; Lloret-Alcaniz, A.

    1998-01-01

    To develop a simple, low-cost technique for the digitization of X-ray films for personal use. A 66-MHz 486 PC with 8 MB of RAM, a Logitech ScanMan 256 hand-held scanner and a standard negatoscope with the power source converted to direct current. Although the system was originally designed for the digitization of mammographies, it has also been used with computed tomography, magnetic resonance, digital angiography and ultrasonographic images, as well as plain X-rays. After a minimal training period, the system digitized X-ray films easily and rapidly. Although the scanning values vary depending on the type of image to be digitized, an input spatial resolution of 200 dpi and a contrast resolution of 256 levels of gray are generally adequate. Of the storage formats tested, JPEG presented the best quality/image size ratio. A simple, low-cost technique has been developed for the digitization of X-ray films. This technique enables the storage of images in a digital format, thus facilitating their presentation and transmission. (Author) 9 refs

  9. A dual-view digital tomosynthesis imaging technique for improved chest imaging

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Yuncheng; Lai, Chao-Jen; Wang, Tianpeng; Shaw, Chris C., E-mail: cshaw@mdanderson.org [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77054 (United States)

    2015-09-15

    Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values

  10. Effect of yoga relaxation techniques on performance of digit-letter substitution task by teenagers.

    Science.gov (United States)

    Pradhan, Balaram; Nagendra, H R

    2009-01-01

    Memory and selective attention are important skills for academic and professional performance. Techniques to improve these skills are not taught either in education or company training courses. Any system which can systematically improve these skills will be of value in schools, universities, and workplaces. To investigate possible improvements in memory and selective attention, as measured by the Digit-Letter Substitution Task (DLST), due to practice of Cyclic Meditation (CM), a yoga relaxation technique, as compared to Supine Rest (SR). Subjects consisted of 253 school students, 156 boys, 97 girls, in the age range 13-16 years, who were attending a 10-day yoga training course during summer vacation. The selected subjects had English as their medium of instruction in school and they acted as their own controls. They were allocated to two groups, and tested on the DLST, immediately before and after 22.5 minutes practice of CM on one day, and immediately before and after an equal period of SR on the other day. The first group performed CM on day 9 and SR on day 10. For the second group, the order was reversed. Within each group pre-post test differences were significant for both the relaxation techniques. The magnitude of net score improvement was greater after SR (7.85%) compared to CM (3.95%). Significance levels were P performance on the DLST. However, these relaxation techniques lead to more wrong cancellation errors.

  11. The use of linear programming techniques to design optimal digital filters for pulse shaping and channel equalization

    Science.gov (United States)

    Houts, R. C.; Burlage, D. W.

    1972-01-01

    A time domain technique is developed to design finite-duration impulse response digital filters using linear programming. Two related applications of this technique in data transmission systems are considered. The first is the design of pulse shaping digital filters to generate or detect signaling waveforms transmitted over bandlimited channels that are assumed to have ideal low pass or bandpass characteristics. The second is the design of digital filters to be used as preset equalizers in cascade with channels that have known impulse response characteristics. Example designs are presented which illustrate that excellent waveforms can be generated with frequency-sampling filters and the ease with which digital transversal filters can be designed for preset equalization.

  12. Reliability Evaluation Methodologies of Fault Tolerant Techniques of Digital I and C Systems in Nuclear Power Plants

    International Nuclear Information System (INIS)

    Kim, Bo Gyung; Kang, Hyun Gook; Seong, Poong Hyun; Lee, Seung Jun

    2011-01-01

    Since the reactor protection system was replaced from analog to digital, digital reactor protection system has 4 redundant channels and each channel has several modules. It is necessary for various fault tolerant techniques to improve availability and reliability due to using complex components in DPPS. To use the digital system, it is necessary to improve the reliability and availability of a system through fault-tolerant techniques. Several researches make an effort to effects of fault tolerant techniques. However, the effects of fault tolerant techniques have not been properly considered yet in most fault tree models. Various fault-tolerant techniques, which used in digital system in NPPs, should reflect in fault tree analysis for getting lower system unavailability and more reliable PSA. When fault-tolerant techniques are modeled in fault tree, categorizing the module to detect by each fault tolerant techniques, fault coverage, detection period and the fault recovery should be considered. Further work will concentrate on various aspects for fault tree modeling. We will find other important factors, and found a new theory to construct the fault tree model

  13. Visible Watermarking Technique Based on Human Visual System for Single Sensor Digital Cameras

    Directory of Open Access Journals (Sweden)

    Hector Santoyo-Garcia

    2017-01-01

    Full Text Available In this paper we propose a visible watermarking algorithm, in which a visible watermark is embedded into the Bayer Colour Filter Array (CFA domain. The Bayer CFA is the most common raw image representation for images captured by single sensor digital cameras equipped in almost all mobile devices. In proposed scheme, the captured image is watermarked before it is compressed and stored in the storage system. Then this method enforces the rightful ownership of the watermarked image, since there is no other version of the image rather than the watermarked one. We also take into consideration the Human Visual System (HVS so that the proposed technique provides desired characteristics of a visible watermarking scheme, such that the embedded watermark is sufficiently perceptible and at same time not obtrusive in colour and grey-scale images. Unlike other Bayer CFA domain visible watermarking algorithms, in which only binary watermark pattern is supported, proposed watermarking algorithm allows grey-scale and colour images as watermark patterns. It is suitable for advertisement purpose, such as digital library and e-commerce, besides copyright protection.

  14. Denoising of electron beam Monte Carlo dose distributions using digital filtering techniques

    International Nuclear Information System (INIS)

    Deasy, Joseph O.

    2000-01-01

    The Monte Carlo (MC) method has long been viewed as the ultimate dose distribution computational technique. The inherent stochastic dose fluctuations (i.e. noise), however, have several important disadvantages: noise will affect estimates of all the relevant dosimetric and radiobiological indices, and noise will degrade the resulting dose contour visualizations. We suggest the use of a post-processing denoising step to reduce statistical fluctuations and also improve dose contour visualization. We report the results of applying four different two-dimensional digital smoothing filters to two-dimensional dose images. The Integrated Tiger Series MC code was used to generate 10 MeV electron beam dose distributions at various depths in two different phantoms. The observed qualitative effects of filtering include: (a) the suppression of voxel-to-voxel (high-frequency) noise and (b) the resulting contour plots are visually more comprehensible. Drawbacks include, in some cases, slight blurring of penumbra near the surface and slight blurring of other very sharp real dosimetric features. Of the four digital filters considered here, one, a filter based on a local least-squares principle, appears to suppress noise with negligible degradation of real dosimetric features. We conclude that denoising of electron beam MC dose distributions is feasible and will yield improved dosimetric reliability and improved visualization of dose distributions. (author)

  15. Digital 3D Borobudur - Integration of 3D surveying and modeling techniques

    Science.gov (United States)

    Suwardhi, D.; Menna, F.; Remondino, F.; Hanke, K.; Akmalia, R.

    2015-08-01

    The Borobudur temple (Indonesia) is one of the greatest Buddhist monuments in the world, now listed as an UNESCO World Heritage Site. The present state of the temple is the result of restorations after being exposed to natural disasters several times. Today there is still a growing rate of deterioration of the building stones whose causes need further researches. Monitoring programs, supported at institutional level, have been effectively executed to observe the problem. The paper presents the latest efforts to digitally document the Borobudur Temple and its surrounding area in 3D with photogrammetric techniques. UAV and terrestrial images were acquired to completely digitize the temple, produce DEM, orthoimages and maps at 1:100 and 1:1000 scale. The results of the project are now employed by the local government organizations to manage the heritage area and plan new policies for the conservation and preservation of the UNESCO site. In order to help data management and policy makers, a web-based information system of the heritage area was also built to visualize and easily access all the data and achieved 3D results.

  16. Soil moisture assessed by digital mapping techniques and its field validation

    Directory of Open Access Journals (Sweden)

    Bruno Montoani Silva

    2014-04-01

    Full Text Available Digital techniques and tools can assist not only in the prediction of soil properties, such as soil moisture, but also in planning the use and management of areas for agriculture and, or, environmental purposes. In this sense, this work aimed to study wetness indexes methods, defining the spatial resolution and selecting the estimation method that best correlates with water content data measured in the field, evaluating even moisture at different soil depths and seasons. This study was developed in a landscape with strongly undulated relief and covered with Nitosols at the summit and upper middle third, and Argisols at the low middle third, ranging in altitude from 845 to 890 m, located in the southern state of Minas Gerais, Brazil. It were performed analyses of Pearson linear correlation between soil moisture determined in the field, at depths of 10, 20, 30, 40, 60 and 100 cm and the water storage in 0-100 cm depth, and the topographic and SAGA wetness indexes, TWI and SWI, respectively, obtained from digital elevation models at different spatial resolutions. In most studied conditions, the TWI with resolution of 10 m provided better results, particularly for the dry season. In this study, only the depth of 100 cm resulted in a significant and positive correlation, suggesting that the moisture levels are suitable for water dynamic studies in the subsurface, assisting in studies of hydrological dynamics and planning the soil use and management, especially for perennial plants with deeper root systems.

  17. Digital 3D Borobudur – Integration of 3D surveying and modeling techniques

    Directory of Open Access Journals (Sweden)

    D. Suwardhi

    2015-08-01

    Full Text Available The Borobudur temple (Indonesia is one of the greatest Buddhist monuments in the world, now listed as an UNESCO World Heritage Site. The present state of the temple is the result of restorations after being exposed to natural disasters several times. Today there is still a growing rate of deterioration of the building stones whose causes need further researches. Monitoring programs, supported at institutional level, have been effectively executed to observe the problem. The paper presents the latest efforts to digitally document the Borobudur Temple and its surrounding area in 3D with photogrammetric techniques. UAV and terrestrial images were acquired to completely digitize the temple, produce DEM, orthoimages and maps at 1:100 and 1:1000 scale. The results of the project are now employed by the local government organizations to manage the heritage area and plan new policies for the conservation and preservation of the UNESCO site. In order to help data management and policy makers, a web-based information system of the heritage area was also built to visualize and easily access all the data and achieved 3D results.

  18. Reconstructing the past: methods and techniques for the digital restoration of fossils.

    Science.gov (United States)

    Lautenschlager, Stephan

    2016-10-01

    During fossilization, the remains of extinct organisms are subjected to taphonomic and diagenetic processes. As a result, fossils show a variety of preservational artefacts, which can range from small breaks and cracks, disarticulation and fragmentation, to the loss and deformation of skeletal structures and other hard parts. Such artefacts can present a considerable problem, as the preserved morphology of fossils often forms the basis for palaeontological research. Phylogenetic and taxonomic studies, inferences on appearance, ecology and behaviour and functional analyses of fossil organisms strongly rely on morphological information. As a consequence, the restoration of fossil morphology is often a necessary prerequisite for further analyses. Facilitated by recent computational advances, virtual reconstruction and restoration techniques offer versatile tools to restore the original morphology of fossils. Different methodological steps and approaches, as well as software are outlined and reviewed here, and advantages and disadvantages are discussed. Although the complexity of the restorative processes can introduce a degree of interpretation, digitally restored fossils can provide useful morphological information and can be used to obtain functional estimates. Additionally, the digital nature of the restored models can open up possibilities for education and outreach and further research.

  19. Nanoscale deformation measurement of microscale interconnection assemblies by a digital image correlation technique

    International Nuclear Information System (INIS)

    Sun Yaofeng; Pang, John H L; Fan Wei

    2007-01-01

    The continuous miniaturization of microelectronic devices and interconnections demand more and more experimental strain/stress analysis of micro- and nanoscale components for material characterization and structure reliability analysis. The digital image correlation (DIC) technique, with the aid of scanning probe microscopes, has become a very promising tool to meet this demand. In this study, an atomic force microscope (AFM) was used to scan and digitally image micro-interconnection assemblies in a micro-thermoelectric cooler. AFM images of the scan region of interest were obtained separately when the microelectronic device was operated before and after the cooling and heating stages. The AFM images were then used to obtain the in-plane deformation fields in the observed region of the micro-assembly. AFM image correlation is performed for nanoscale deformation analysis using the authors' AFM-DIC program. The results show that the observed region was subjected to cyclic strains when the device worked between its cooling and heating stages, and cyclic strain in the vertical direction was found to be a significant deformation mode. The thermally induced deformation behavior of the micro-assembly device was modeled by finite element analysis (FEA). Both thermal-electric analysis and thermal stress analysis were conducted on a 3D finite element model of the device. It is shown that the experimental results were able to validate the finite element analysis results

  20. Digital Image Correlation Techniques Applied to Large Scale Rocket Engine Testing

    Science.gov (United States)

    Gradl, Paul R.

    2016-01-01

    Rocket engine hot-fire ground testing is necessary to understand component performance, reliability and engine system interactions during development. The J-2X upper stage engine completed a series of developmental hot-fire tests that derived performance of the engine and components, validated analytical models and provided the necessary data to identify where design changes, process improvements and technology development were needed. The J-2X development engines were heavily instrumented to provide the data necessary to support these activities which enabled the team to investigate any anomalies experienced during the test program. This paper describes the development of an optical digital image correlation technique to augment the data provided by traditional strain gauges which are prone to debonding at elevated temperatures and limited to localized measurements. The feasibility of this optical measurement system was demonstrated during full scale hot-fire testing of J-2X, during which a digital image correlation system, incorporating a pair of high speed cameras to measure three-dimensional, real-time displacements and strains was installed and operated under the extreme environments present on the test stand. The camera and facility setup, pre-test calibrations, data collection, hot-fire test data collection and post-test analysis and results are presented in this paper.

  1. Introduction to digital instrumentation and control techniques used in nuclear engineering

    International Nuclear Information System (INIS)

    Kurilla, R.G.; Kenney, E.S.

    1988-01-01

    For the past 8 yr, the nuclear engineering department at Pennsylvania State University has been teaching a digital interfacing class at the undergraduate (senior) level. With the ever-increasing use of computers in the nuclear engineering area (such as in the use of automated data acquisition systems) and the complexity of control instrumentation, more than a cursory introduction into electronics and computer controls is needed. Because of the ever-increasing popularity, and hence importance, of IBM-PC compatible microcomputers in the engineering fields, the program has been adapted to the Intel 8086 microprocessor. Courses such as this one are helpful in ensuring the students have an adequate design and practice base as required by accrediting groups. The course, is composed of three parts: (1) machine code/assembly language, (2) interfacing, and (3) final project. Experience demonstrates that a course of this inherent complexity can successfully be taught within a nuclear engineering curriculum without extensive prerequisites. The important ingredient is to treat nuclear engineering students for exactly what they are, engineers. By having them use their creativity and adaptability, they can successfully integrate the digital interfacing techniques now routinely used in the nuclear industry

  2. Modulation format identification enabled by the digital frequency-offset loading technique for hitless coherent transceiver.

    Science.gov (United States)

    Fu, Songnian; Xu, Zuying; Lu, Jianing; Jiang, Hexun; Wu, Qiong; Hu, Zhouyi; Tang, Ming; Liu, Deming; Chan, Calvin Chun-Kit

    2018-03-19

    We propose a blind and fast modulation format identification (MFI) enabled by the digital frequency-offset (FO) loading technique for hitless coherent transceiver. Since modulation format information is encoded to the FO distribution during digital signal processing (DSP) at the transmitter side (Tx), we can use the fast Fourier transformation based FO estimation (FFT-FOE) method to obtain the FO distribution of individual data block after constant modulus algorithm (CMA) pre-equalization at the receiver side, in order to realize non-data-aided (NDA) and fast MFI. The obtained FO can be also used for subsequent FO compensation (FOC), without additional complexity. We numerically investigate and experimentally verify the proposed MFI with high accuracy and fast format switching among 28 Gbaud dual-polarization (DP)-4/8/16/64QAM, time domain hybrid-4/16QAM, and set partitioning (SP)-128QAM. In particular, the proposed MFI brings no performance degradation, in term of tolerance of amplified spontaneous emission (ASE) noise, laser linewidth, and fiber nonlinearity. Finally, a hitless coherent transceiver enabled by the proposed MFI with switching-block of only 2048 symbols is demonstrated over 1500 km standard single mode fiber (SSMF) transmission.

  3. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K

    2018-03-22

    Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018. Published by Elsevier Inc.

  4. 99mTc-RBC subtraction scintigraphy

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Kuranishi, Makoto; Sugishita, Kouki; Nakamura, Mamoru

    1994-01-01

    Sequential abdominal scintigrams with 99m Tc-labelled red blood cells (RBC) were subtracted for observing a site of gastrointestinal bleeding and calculating the bleeding rate. This method is technically very easy and can detect the site of bleeding with the minimum rate, as low as 0.2 ml/min., in a phantom experiment. In 23 cases with final diagnosis of gastrointestinal bleeding, conventional non-subtraction scintigraphy detected only 30% (7/23), but subtraction scintigraphy detected 61% (14/23). It was concluded that subtraction scintigraphy had higher sensitivity than conventional scintigraphy for early diagnosing bleeding. A combination of non-subtraction and subtraction scintigraphy is recommended to detect a site of gastrointestinal bleeding in a clinical setting. (author)

  5. Mechanical behavior study of single cell contraction by digital image correlation technique

    Science.gov (United States)

    Huang, Jianyong; Wu, Jia; Qin, Lei; Zhu, Tao; Xiong, Chunyang; Zhang, Youyi; Fang, Jing

    2008-11-01

    Precise determination of cellular traction forces has important significance in assessing cellular mechanical characteristic on micro/nano scale. Elastic substrate method is a useful way to study cellular traction forces, in which the cells are cultured on elastic gel substrate marked by randomly embedding fluorescent microbeads and they exert mechanical forces on the film to cause deformation of the substrate material. In this paper, we investigate the acquisition of deformation field induced by single cardiac myocyte by using digital image correlation (DIC) technique. In view of the fact that cellular force restoration is essentially an ill-posed inverse problem, which implies that the force reconstruction is susceptible to the input displacement noise, we develop a novel optimal filtering scheme in two-dimensional Fourier space to restrain displacement noise amplification. Experiments of traction force recovery for a real cardiac myocyte indicate the optimal scheme in combination with the DIC method enables us to reconstruct cellular traction fields with high accuracy.

  6. Digital image integration technique of multi-geoscience information dominated by aerial radiometric measurements

    International Nuclear Information System (INIS)

    Liu Dechang; Sun Maorong; Zhu Deling; Zhang Jingbo; He Jianguo; Dong Xiuzhen

    1992-02-01

    The geologic metallogenetic environment of uranium at Lian Shan Guan region has been studied by using digital image integration technique of multi-geoscience information with aerial radiometric measurements. It includes the classification of uranium-bearing rock, recognizing patterns of ore-forming and geologic mapping in ore field. Some new tectonic structure was found in this region that gives significant information for further exploring of uranium ore. After multi-parameters screening of aerial radiometric data, patterns recognizing and multi-geoscience information integration analysis, four prospective metallogenetic zones were predicted, and the predication was proved by further geologic survey. Three of the four zones are very encouraging, where ore-forming structures, hydrothermal deposits, wall-rock alteration, primary and secondary uranium ore and rich uranium mineralization are discovered. The department of geologic exploring has decided that these zones will enjoy priority in the examination for further prospecting of uranium ores

  7. Digital Control Techniques Based on Voltage Source Inverters in Renewable Energy Applications: A Review

    Directory of Open Access Journals (Sweden)

    Sohaib Tahir

    2018-02-01

    Full Text Available In the modern era, distributed generation is considered as an alternative source for power generation. Especially, need of the time is to provide the three-phase loads with smooth sinusoidal voltages having fixed frequency and amplitude. A common solution is the integration of power electronics converters in the systems for connecting distributed generation systems to the stand-alone loads. Thus, the presence of suitable control techniques, in the power electronic converters, for robust stability, abrupt response, optimal tracking ability and error eradication are inevitable. A comprehensive review based on design, analysis, validation of the most suitable digital control techniques and the options available for the researchers for improving the power quality is presented in this paper with their pros and cons. Comparisons based on the cost, schemes, performance, modulation techniques and coordinates system are also presented. Finally, the paper describes the performance evaluation of the control schemes on a voltage source inverter (VSI and proposes the different aspects to be considered for selecting a power electronics inverter topology, reference frames, filters, as well as control strategy.

  8. Adaptive digital fringe projection technique for high dynamic range three-dimensional shape measurement.

    Science.gov (United States)

    Lin, Hui; Gao, Jian; Mei, Qing; He, Yunbo; Liu, Junxiu; Wang, Xingjin

    2016-04-04

    It is a challenge for any optical method to measure objects with a large range of reflectivity variation across the surface. Image saturation results in incorrect intensities in captured fringe pattern images, leading to phase and measurement errors. This paper presents a new adaptive digital fringe projection technique which avoids image saturation and has a high signal to noise ratio (SNR) in the three-dimensional (3-D) shape measurement of objects that has a large range of reflectivity variation across the surface. Compared to previous high dynamic range 3-D scan methods using many exposures and fringe pattern projections, which consumes a lot of time, the proposed technique uses only two preliminary steps of fringe pattern projection and image capture to generate the adapted fringe patterns, by adaptively adjusting the pixel-wise intensity of the projected fringe patterns based on the saturated pixels in the captured images of the surface being measured. For the bright regions due to high surface reflectivity and high illumination by the ambient light and surfaces interreflections, the projected intensity is reduced just to be low enough to avoid image saturation. Simultaneously, the maximum intensity of 255 is used for those dark regions with low surface reflectivity to maintain high SNR. Our experiments demonstrate that the proposed technique can achieve higher 3-D measurement accuracy across a surface with a large range of reflectivity variation.

  9. A novel pre-processing technique for improving image quality in digital breast tomosynthesis.

    Science.gov (United States)

    Kim, Hyeongseok; Lee, Taewon; Hong, Joonpyo; Sabir, Sohail; Lee, Jung-Ryun; Choi, Young Wook; Kim, Hak Hee; Chae, Eun Young; Cho, Seungryong

    2017-02-01

    Nonlinear pre-reconstruction processing of the projection data in computed tomography (CT) where accurate recovery of the CT numbers is important for diagnosis is usually discouraged, for such a processing would violate the physics of image formation in CT. However, one can devise a pre-processing step to enhance detectability of lesions in digital breast tomosynthesis (DBT) where accurate recovery of the CT numbers is fundamentally impossible due to the incompleteness of the scanned data. Since the detection of lesions such as micro-calcifications and mass in breasts is the purpose of using DBT, it is justified that a technique producing higher detectability of lesions is a virtue. A histogram modification technique was developed in the projection data domain. Histogram of raw projection data was first divided into two parts: One for the breast projection data and the other for background. Background pixel values were set to a single value that represents the boundary between breast and background. After that, both histogram parts were shifted by an appropriate amount of offset and the histogram-modified projection data were log-transformed. Filtered-backprojection (FBP) algorithm was used for image reconstruction of DBT. To evaluate performance of the proposed method, we computed the detectability index for the reconstructed images from clinically acquired data. Typical breast border enhancement artifacts were greatly suppressed and the detectability of calcifications and masses was increased by use of the proposed method. Compared to a global threshold-based post-reconstruction processing technique, the proposed method produced images of higher contrast without invoking additional image artifacts. In this work, we report a novel pre-processing technique that improves detectability of lesions in DBT and has potential advantages over the global threshold-based post-reconstruction processing technique. The proposed method not only increased the lesion detectability

  10. The development of advanced instrumentation and control technology -The development of digital monitoring technique-

    Energy Technology Data Exchange (ETDEWEB)

    Jun, Jong Sun; Lee, Byung Sun; Han, Sang Joon; Shin, Yong Chul; Kim, Yung Baek; Kim, Dong Hoon; Oh, Yang Kyoon; Suh, Yung; Choi, Chan Duk; Kang, Byung Hun; Hong, Hyung Pyo; Shin, Jee Tae; Moon, Kwon Kee; Lee, Soon Sung; Kim, Sung Hoh; Koo, In Soo; Kim, Dong Wan; Huh, Sub [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-07-01

    A study has been performed for the advanced DSP technology for digital nuclear I and C systems and its prototype, and for the monitoring and diagnosing techniques for the highly-pressurized components in NSSS. In the DSP part, the DSP requirements for NPPs have been induced for the performance of the DSP systems and the functional analysis for Reactor Coolant System (RCS) has been performed as the embodied target system. Total quantities of the I and C signals, signal types, and signal functions were also investigated in Ulchin NPP units 3 and 4. From these basis, the prototype facility was configured for performance validation and algorithm implementation. In order to develop the methods of DSP techniques and algorithms, the current signal validation methods have been studied and analyzed. In the analysis for the communication networks in NPP, the basic technique for the configuration of communication networks and the important considerations for applying to NPPs have been reviewed. Test and experimental facilities have been set up in order to carry out the required tests during research activities on the monitoring techniques for abnormal conditions. Studies were concentrated on methods how to acquire vibration signals from the mechanical structures and equipment including rotating machinery and reactor, and analyses for the characteristics of the signals. Fuzzy logic was evaluated as a good technique to improve the reliability of the monitoring and diagnosing algorithm through the application of the theory such as the automatic pattern recognition algorithm of the vibration spectrum, the alarm detection and diagnosis for collisions of loose parts. 71 figs, 32 tabs, 64 refs. (Author).

  11. Case study: The Avengers 3D: cinematic techniques and digitally created 3D

    Science.gov (United States)

    Clark, Graham D.

    2013-03-01

    Marvel's THE AVENGERS was the third film Stereo D collaborated on with Marvel; it was a summation of our artistic development of what Digitally Created 3D and Stereo D's artists and toolsets affords Marvel's filmmakers; the ability to shape stereographic space to support the film and story, in a way that balances human perception and live photography. We took our artistic lead from the cinematic intentions of Marvel, the Director Joss Whedon, and Director of Photography Seamus McGarvey. In the digital creation of a 3D film from a 2D image capture, recommendations to the filmmakers cinematic techniques are offered by Stereo D at each step from pre-production onwards, through set, into post. As the footage arrives at our facility we respond in depth to the cinematic qualities of the imagery in context of the edit and story, with the guidance of the Directors and Studio, creating stereoscopic imagery. Our involvement in The Avengers was early in production, after reading the script we had the opportunity and honor to meet and work with the Director Joss Whedon, and DP Seamus McGarvey on set, and into post. We presented what is obvious to such great filmmakers in the ways of cinematic techniques as they related to the standard depth cues and story points we would use to evaluate depth for their film. Our hope was any cinematic habits that supported better 3D would be emphasized. In searching for a 3D statement for the studio and filmmakers we arrived at a stereographic style that allowed for comfort and maximum visual engagement to the viewer.

  12. Comparison of palmar digital neurectomy by the guillotine technique and palmar digital neurotomy associated with end-to-side neurorrhaphy in mares

    Directory of Open Access Journals (Sweden)

    Taís Brito Santana

    2016-06-01

    Full Text Available Five mares were submitted to palmar digital neurectomy by the guillotine technique and palmar digital neurotomy followed by end-to-side neurorrhaphy (right and left thoracic limbs, respectively. Mares were checked for local pain sensation using hoof tester and submitted to lameness workup at 15-day intervals. No evidence of painful neuroma formation was detected. Palmar digital nerve (PDN stump segments were collected within 60 days of surgery. Mean left and right limb PDN stump thickness corresponded to 5.96 mm and 7.16 mm, respectively. Schwann cells prevailed over connective healing tissue in all PDN stumps studied. Well-formed nerve-like structures with better organized nervous tissue and predominance of parallel nerve fiber orientation were documented in left limb PDN stumps. End-to-side neurorrhaphy tended to promote tissue organization, potentially reducing the chances of neuroma formation.

  13. Digital radiography: study of an alternative technique to conventional radiography; La Radiographie Numerique: etude d'une technique alternative a la radiographie conventionnelle

    Energy Technology Data Exchange (ETDEWEB)

    Banchet, J. [AREVA, AREVA NP, NETEC, The Areva Nondestructive Examination Technical Center, 69 - Lyon (France); Tisseur, D. [AREVA, AREVA NP, Intercontrole, 71 - Chalon sur Saone (France); Thomas, A. [AREVA, AREVA NP, 92 - Colombes (France)

    2009-07-01

    Digital radiography, already in use in many industrial applications, appears as a potential alternative technique to conventional radiography in the nuclear field (and more especially to the inspection of welded joints). The advantages of digital radiography are a reduced explosion risk (due to the use of lower energy and activity sources), a lower installation time, a reduced exclusion zone, and the absence of effluents. However, to the contrary of the US case, this technique may not be used in France as it is not referenced in the regulating codes (RCCM, etc.). Areva has launched a R and D study in order to characterize the equivalencies between digital and conventional radiography. First results of this study are given

  14. Effect of yoga relaxation techniques on performance of digit-letter substitution task by teenagers

    Directory of Open Access Journals (Sweden)

    Pradhan Balaram

    2009-01-01

    Full Text Available Background/Aims : Memory and selective attention are important skills for academic and professional performance. Techniques to improve these skills are not taught either in education or company training courses. Any system which can systematically improve these skills will be of value in schools, universities, and workplaces. Aims:To investigate possible improvements in memory and selective attention, as measured by the Digit-Letter Substitution Task (DLST, due to practice of Cyclic Meditation (CM, a yoga relaxation technique, as compared to Supine Rest (SR. Materials and Methods : Subjects consisted of 253 school students, 156 boys, 97 girls, in the age range 13-16 years, who were attending a 10-day yoga training course during summer vacation. The selected subjects had English as their medium of instruction in school and they acted as their own controls. They were allocated to two groups, and tested on the DLST, immediately before and after 22.5 minutes practice of CM on one day, and immediately before and after an equal period of SR on the other day. The first group performed CM on day 9 and SR on day 10. For the second group, the order was reversed. Results : Within each group pre-post test differences were significant for both the relaxation techniques. The magnitude of net score improvement was greater after SR (7.85% compared to CM (3.95%. Significance levels were P < 0.4 x 10 -9 for SR and P < 0.1 x 10 -3 for CM. The number of wrong attempts also increased significantly on both interventions, even after removing two outlier data points on day 1 in the SR group. Conclusions: Both CM and SR lead to improvement in performance on the DLST. However, these relaxation techniques lead to more wrong cancellation errors.

  15. New method for numerical approximations of vector derivatives based on digital signal processing techniques

    Science.gov (United States)

    Brice, Henry; Ahmed, Mohammed Z.

    2012-05-01

    Accurate propagation models are required for predicting the propagation of electromagnetic waves within complex environments. This paper proposes the use of a new method to accurately compute the divergence and curl of electromagnetic fields. The computation of the derivatives of vector fields is normally approximated using numerical methods such as the Finite-Dierence Time-Domain Method (FDTD), the Finite Integration Technique and the Multi-Resolution Time-Domain Method. These methods are all limited in terms of their accuracy, resolution, computational efficiency and numerical stability. This paper introduces a new method for computing derivatives based on Two-Dimensional (2D) Digital Signal Processing (DSP) techniques. The method involves computing a numerical approximation of the derivative of a function by considering the frequency domain definition of the derivative and designing a 2Dfinite impulse response (FIR) filter that implements the differentiation. Appropriate windowing functions are used to ensure that the FIR response is as close to the ideal 2D differentiator response as possible. This paper provides an example where the curl of a vectorfield is determined using this method and accuracy within a few percent is achieved. The proposed innovative method can be extended to three dimensions and used to find numerical solutions of Maxwells Equations, thus allowing it to be applied to the design of accurate propagation models.

  16. Performance evaluation of algebraic reconstruction technique (ART) for prototype chest digital tomosynthesis (CDT) system

    Science.gov (United States)

    Lee, Haenghwa; Choi, Sunghoon; Jo, Byungdu; Kim, Hyemi; Lee, Donghoon; Kim, Dohyeon; Choi, Seungyeon; Lee, Youngjin; Kim, Hee-Joung

    2017-03-01

    Chest digital tomosynthesis (CDT) is a new 3D imaging technique that can be expected to improve the detection of subtle lung disease over conventional chest radiography. Algorithm development for CDT system is challenging in that a limited number of low-dose projections are acquired over a limited angular range. To confirm the feasibility of algebraic reconstruction technique (ART) method under variations in key imaging parameters, quality metrics were conducted using LUNGMAN phantom included grand-glass opacity (GGO) tumor. Reconstructed images were acquired from the total 41 projection images over a total angular range of +/-20°. We evaluated contrast-to-noise ratio (CNR) and artifacts spread function (ASF) to investigate the effect of reconstruction parameters such as number of iterations, relaxation parameter and initial guess on image quality. We found that proper value of ART relaxation parameter could improve image quality from the same projection. In this study, proper value of relaxation parameters for zero-image (ZI) and back-projection (BP) initial guesses were 0.4 and 0.6, respectively. Also, the maximum CNR values and the minimum full width at half maximum (FWHM) of ASF were acquired in the reconstructed images after 20 iterations and 3 iterations, respectively. According to the results, BP initial guess for ART method could provide better image quality than ZI initial guess. In conclusion, ART method with proper reconstruction parameters could improve image quality due to the limited angular range in CDT system.

  17. Tomosynthesis and contrast-enhanced digital mammography: recent advances in digital mammography

    International Nuclear Information System (INIS)

    Diekmann, Felix; Bick, Ulrich

    2007-01-01

    Digital mammography is more and more replacing conventional mammography. Initial concerns about an inferior image quality of digital mammography have been largely overcome and recent studies even show digital mammography to be superior in women with dense breasts, while at the same time reducing radiation exposure. Nevertheless, an important limitation of digital mammography remains: namely, the fact that summation may obscure lesions in dense breast tissue. However, digital mammography offers the option of so-called advanced applications, and two of these, contrast-enhanced mammography and tomosynthesis, are promising candidates for improving the detection of breast lesions otherwise obscured by the summation of dense tissue. Two techniques of contrast-enhanced mammography are available: temporal subtraction of images acquired before and after contrast administration and the so-called dual-energy technique, which means that pairs of low/high-energy images acquired after contrast administration are subtracted. Tomosynthesis on the other hand provides three-dimensional information on the breast. The images are acquired with different angulations of the X-ray tube while the object or detector is static. Various reconstruction algorithms can then be applied to the set of typically nine to 28 source images to reconstruct 1-mm slices with a reduced risk of obscuring pathology. Combinations of both advanced applications have only been investigated in individual experimental studies; more advanced software algorithms and CAD systems are still in their infancy and have only undergone preliminary clinical evaluation. (orig.)

  18. Addition and Subtraction, and Algorithms in General

    Science.gov (United States)

    Fielker, David

    2007-01-01

    The juxtaposition of articles by Ian Thompson and Ian Sugarman in "MT202" on addition and subtraction respectively engendered some bemused thoughts in this author, who for some years has been sheltered from controversy by retirement. In this article, Fielker shares some thoughts on addition and subtraction raised by Thompson and Sugarman in their…

  19. Treatment comfort, time perception, and preference for conventional and digital impression techniques : A comparative study in young patients

    NARCIS (Netherlands)

    Burhardt, Lukasz; Livas, Christos; Kerdijk, Wouter; van der Meer, Wicher Joerd; Ren, Yijin

    INTRODUCTION: The aim of this crossover study was to assess perceptions and preferences for impression techniques in young orthodontic patients receiving alginate and 2 different digital impressions. METHODS: Thirty-eight subjects aged 10 to 17 years requiring impressions for orthodontic treatment

  20. Contrast-enhanced digital mammography

    Energy Technology Data Exchange (ETDEWEB)

    Dromain, Clarisse [Department of Radiology, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France)], E-mail: dromain@igr.fr; Balleyguier, Corinne; Adler, Ghazal [Department of Radiology, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France); Garbay, Jean Remi [Department of Surgery, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France); Delaloge, Suzette [Department of Medicine, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex (France)

    2009-01-15

    CEDM is a recent development of digital mammography using the intra-venous injection of an iodinated contrast agent in conjunction with a mammography examination. Two techniques have been developed to perform CEDM examinations: the temporal subtraction technique with acquisition of high-energy images before and after contrast medium injection and the dual energy technique with acquisition of a pair of low and high-energy images only after contrast medium injection. The temporal subtraction technique offered the possibility to analyze the kinetic curve of enhancement of breast lesions, similarly to breast MRI. The dual energy technique do not provide information about the kinetic of tumor enhancement but allows the acquisition of multiples views of the same breast or bilateral examination and is less sensitive to patient motion than temporal CEDM. Initial clinical experience has shown the ability of CEDM to map the distribution of neovasculature induced by cancer using mammography. Moreover, previous studies have shown a superiority of MX + CEDM, either for the assessment of the probability of malignancy than for BIRADS assessment comparing to MX alone. The potential clinical applications are the clarification of mammographically equivocal lesions, the detection of occult lesions on standard mammography, particularly in dense breast, the determination of the extent of disease, the assessment of recurrent disease and the monitoring of the response to chemotherapy. CEDM should result in a simple way to enhance the detection and the characterization of breast lesions.

  1. Use of higher order signal moments and high speed digital sampling technique for neutron flux measurements

    Science.gov (United States)

    Baers, L. B.; Gutierrez, T. Rivero; Mendoza, R. A. Carrillo; Santana, G. Jimenez

    1993-08-01

    The second (conventional variance or Campbell signal), the third, and the modified fourth order central signal moments associated with the amplified and filtered currents from two electrodes of an ex-core neutron sensitive fission detector were measured versus the reactor power of the 1-MW TRIGA reactor in Mexico City. Two channels of a high-speed (400-MHz) multiplexing data sampler and an analog-to-digital converter with 12-b resolution and 1-Mword buffer memory were used. The data were further retrieved into a PC, and estimates for autocorrelation and cross-correlation moments up to the fifth order, coherence, skewness, excess, etc., quantities were calculated offline. Five-mode operation of the detector was achieved, including conventional counting rates and currents in agreement with theory and the authors' previous results with analog techniques. The signals are proportional to the neutron flux and reactor power in some flux ranges. The suppression of background noise is improved and the lower limit of the measurement range is extended as the order of moment is increased, in agreement with theory.

  2. Compressive Sensing for Background Subtraction

    Science.gov (United States)

    2009-12-20

    i) reconstructing an image using only a single optical pho- todiode (infrared, hyperspectral, etc.) along with a digital micromirror device (DMD...NSF CCF-0431150, ONR N00014-07-1-0936,AFOSR FA9550-07-1-0301,AROW911NF-07-1-0502,AROMURI W311NF-07-1-0185, and the Texas Instruments Leadership

  3. Virtual instrumentation technique used in the nuclear digital signal processing system design: Energy and time measurement tests

    International Nuclear Information System (INIS)

    Pechousek, J.; Prochazka, R.; Prochazka, V.; Frydrych, J.

    2011-01-01

    In this report, computer-based digital signal processing system with a 200 MS s -1 sampling digitizer is presented. Virtual instrumentation technique is used to easily develop a system which provides spectroscopy measurements such as amplitude and time signal analysis, with the time-of-flight facility. Several test measurements were performed to determine the characteristics of a system. The presented system may find its application in the coincidence measurement since the system is usable for different types of detectors and sensitive to decay lifetimes from tens of nanoseconds to seconds.

  4. A high-linearity digital-to-time converter technique: constant-slope charging

    NARCIS (Netherlands)

    Ru, Z.; Palattella, Claudia; Geraedts, P.F.J.; Klumperink, Eric A.M.; Nauta, Bram

    2015-01-01

    A digital-to-time converter (DTC) controls time delay by a digital code, which is useful, for example, in a sampling oscilloscope, fractional-N PLL, or time-interleaved ADC. This paper proposes constant-slope charging as a method to realize a DTC with intrinsically better integral non-linearity

  5. Subarachnoid hemorrhage: role of subtraction CT angiography in etiological diagnosis and pretreatment planning.

    Science.gov (United States)

    Li, K; Wei, X; Lv, F; Li, Q; Xie, P

    2014-12-01

    Subarachnoid hemorrhage (SAH) is a deleterious cerebrovascular disorder that requires prompt etiological diagnosis. We wished to evaluate the diagnostic performance of the latest generation 3D subtraction CT angiography (CTA) in etiological diagnosis and pretreatment planning of patients with suspected SAH. A total of 88 patients were included in our study and underwent both 3D subtraction CTA and digital subtraction angiography (DSA) examinations. The 3D subtraction CTA images were reviewed by two independent readers who were blinded to the results of DSA. Sensitivity, specificity, positive and negative predictive values of 3D subtraction CTA were calculated on a per-patient basis. The possibility for surgical treatment was also evaluated based on information provided by CTA alone. According to DSA results, 72 patients were diagnosed with ruptured intracranial aneurysms, 5 patients with arteriovenous malformations, and no lesion was detected in 11 patients. Sensitivity, specificity, positive predictive value and negative predictive values of CTA for etiological evaluation of SAH were all 100%. Correct pretreatment decision was made in 67 of 70 patients based on the CTA measurements alone. THE results of our study indicate that 3D subtraction CTA is an accurate, fast and non-invasive imaging modality that is equal to DSA in etiological evaluation and pretreatment planning of patients with suspected SAH. It may replace DSA as the first step imaging method in patients with suspected SAH, while DSA should still be reserved for case of uncertainty.

  6. Applying random forest and subtractive fuzzy c-means clustering techniques for the development of a novel G protein-coupled receptor discrimination method using pseudo amino acid compositions.

    Science.gov (United States)

    Sokouti, Babak; Rezvan, Farshad; Dastmalchi, Siavoush

    2015-08-01

    G protein-coupled receptors (GPCRs) constitute the largest superfamily of integral membrane proteins (IMPs) and they tremendously contribute in the flow of information into cells. In this study, the random forest (RF) and the subtractive fuzzy c-means clustering (SBC) methods have been used to determine the importance of input variables and discriminate GPCRs from non-GPCRs using twenty amino acid and fifty pseudo amino acid compositions derived from GPCR sequences. The studied dataset was retrieved from the UniProt/SWISSPROT database and consists of 1000 GPCR and 1000 non-GPCR reviewed sequences. The top ranked RF-SBC-based model discriminates GPCRs and non-GPCRs successfully with the accuracy, sensitivity, specificity and Matthew's coefficient correlation (MCC) rates of 99.15%, 99.60%, 98.70% and 0.983%, respectively. These rates were obtained from averaged values of 5-fold cross validation using only twenty four out of fifty pseudo amino acid composition features. The results show that the proposed RF-SBC-based model outperforms other existing algorithms in terms of the evaluated performance criteria. The webserver for the proposed algorithm is available at http://brcinfo.shinyapps.io/GPCRIden.

  7. The Role of Bone Subtraction Computed Tomographic Angiography in Determining Intracranial Aneurysms in Non-Traumatic Subarachnoid Hemorrhage

    International Nuclear Information System (INIS)

    Kayhan, Aysegul; Koc, Osman; Keskin, Suat; Keskin, Fatih

    2014-01-01

    The presence of blood in the subarachnoid space is an acute pathology with a serious risk of death and complications. The most common etiology (approximately 80%) is intracranial aneurysm. The aim of this study was to assess the role of bone subtracted computed tomographic angiography (BSCTA), a novel and noninvasive method for determining and characterizing intracranial aneurysms. Sixty consecutive patients with clinically suspected non-traumatic subarachnoid hemorrhage (SAH) were considered to enter the study. The subtraction quality was inadequate in ten patients; thus, they were excluded, leaving 50 patients (84.4%) in the study. Bone subtracted and non-subtracted 3D images were obtained from the BSCTA raw data sets. All images obtained by digital subtraction angiography (DSA), BSCTA, and computed tomographic angiography (CTA) were evaluated for the presence or absence of an aneurysm and the location, minimal sac diameter, and neck size ratio of the aneurysm. DSA was considered as the gold standard during the evaluation of the data. Of the 50 patients who participated in this study, 11 had no aneurysms as determined by both CTA and DSA. Examination of the remaining 39 patients revealed the presence of 51 aneurysms. While 3D-CTA could not detect six aneurysms that were located in the base of the skull, 3D-BSCTA easily detected them. Moreover, five aneurysms were only partially detected by 3D-CTA. According to this data, the sensitivity of 3D-BSCTA and 3D-CTA was calculated as 98% and 86.3%, respectively; the specificity was calculated as 100% and 90.9%, respectively, per aneurysm; and the sensitivity of 100% for 3D-BSCTA and 98% for 3D-CTA was achieved by using combined images with multi-planar reconstruction (MPR) and maximum intensity projection (MIP). BSCTA detected and characterized the aneurysms as well as DSA, and BSCTA and DSA gave concordant results in detecting aneurysms. BSCTA is easily accessible, less time consuming, and most importantly, a non

  8. The Role of Bone Subtraction Computed Tomographic Angiography in Determining Intracranial Aneurysms in Non-Traumatic Subarachnoid Hemorrhage

    Science.gov (United States)

    Kayhan, Aysegul; Koc, Osman; Keskin, Suat; Keskin, Fatih

    2014-01-01

    Background: The presence of blood in the subarachnoid space is an acute pathology with a serious risk of death and complications. The most common etiology (approximately 80%) is intracranial aneurysm. Objectives: The aim of this study was to assess the role of bone subtracted computed tomographic angiography (BSCTA), a novel and noninvasive method for determining and characterizing intracranial aneurysms. Patients and Methods: Sixty consecutive patients with clinically suspected non-traumatic subarachnoid hemorrhage (SAH) were considered to enter the study. The subtraction quality was inadequate in ten patients; thus, they were excluded, leaving 50 patients (84.4%) in the study. Bone subtracted and non-subtracted 3D images were obtained from the BSCTA raw data sets. All images obtained by digital subtraction angiography (DSA), BSCTA, and computed tomographic angiography (CTA) were evaluated for the presence or absence of an aneurysm and the location, minimal sac diameter, and neck size ratio of the aneurysm. DSA was considered as the gold standard during the evaluation of the data. Results: Of the 50 patients who participated in this study, 11 had no aneurysms as determined by both CTA and DSA. Examination of the remaining 39 patients revealed the presence of 51 aneurysms. While 3D-CTA could not detect six aneurysms that were located in the base of the skull, 3D-BSCTA easily detected them. Moreover, five aneurysms were only partially detected by 3D-CTA. According to this data, the sensitivity of 3D-BSCTA and 3D-CTA was calculated as 98% and 86.3%, respectively; the specificity was calculated as 100% and 90.9%, respectively, per aneurysm; and the sensitivity of 100% for 3D-BSCTA and 98% for 3D-CTA was achieved by using combined images with multi-planar reconstruction (MPR) and maximum intensity projection (MIP). BSCTA detected and characterized the aneurysms as well as DSA, and BSCTA and DSA gave concordant results in detecting aneurysms. Conclusions: BSCTA is

  9. Distinct representations of subtraction and multiplication in the neural systems for numerosity and language

    Science.gov (United States)

    Prado, Jérôme; Mutreja, Rachna; Zhang, Hongchuan; Mehta, Rucha; Desroches, Amy S.; Minas, Jennifer E.; Booth, James R.

    2010-01-01

    It has been proposed that recent cultural inventions such as symbolic arithmetic recycle evolutionary older neural mechanisms. A central assumption of this hypothesis is that the degree to which a pre-existing mechanism is recycled depends upon the degree of similarity between its initial function and the novel task. To test this assumption, we investigated whether the brain region involved in magnitude comparison in the intraparietal sulcus (IPS), localized by a numerosity comparison task, is recruited to a greater degree by arithmetic problems that involve number comparison (single-digit subtractions) than by problems that involve retrieving facts from memory (single-digit multiplications). Our results confirmed that subtractions are associated with greater activity in the IPS than multiplications, whereas multiplications elicit greater activity than subtractions in regions involved in verbal processing including the middle temporal gyrus and inferior frontal gyrus that were localized by a phonological processing task. Pattern analyses further indicated that the neural mechanisms more active for subtraction than multiplication in the IPS overlap with those involved in numerosity comparison, and that the strength of this overlap predicts inter-individual performance in the subtraction task. These findings provide novel evidence that elementary arithmetic relies on the co-option of evolutionary older neural circuits. PMID:21246667

  10. Investigation of various reconstruction parameters for algebraic reconstruction technique in a newly developed chest digital tomosynthesis

    International Nuclear Information System (INIS)

    Lee, H.; Choi, S.; Kim, Y.-S.; Park, H.-S.; Seo, C.-W.; Kim, H.-J.; Lee, D.; Lee, Y.

    2017-01-01

    Chest digital tomosynthesis (CDT) is a promising new modality that provides 3D information by reconstructing limited projection views. CDT systems have been developed to improve the limitations of conventional radiography such as image degradation and low sensitivity. However, the development of reconstruction methods is challenging because of the limited projection views within various angular ranges. Optimization of reconstruction parameters for various reconsturction methods in CDT system also is needed. The purpose of this study was to investigate the feasibility of algebraic reconstruction technique (ART) method, and to evaluate the effect of the reconstruction parameters for our newly developed CDT system. We designed ART method with 41 projection views over an angular range of ±20°. To investigate the effect of reconstruction parameters, we measured the contrast-to-noise ratio (CNR), artifact spread function (ASF), and quality factor (QF) using LUNGMAN phantom included tumors. We found that the proper choice of reconstruction parameters such as relaxation parameter, initial guess, and number of iterations improved the quality of reconstructed images from the same projection views. Optimal values of ART relaxation parameter with uniform (UI) and back-projection (BP) initial guesses were 0.4 and 0.6, respectively. BP initial guess improved image quality in comparison with UI initial guess, in terms of providing a higher CNR and QF values with a faster speed. CNR and QF values improved with increasing number of iteration. Particularly, ART method with BP initial guess (when β = 0.6) after 3-terations provide satisfactory reconstructed image. In conclusion, the use of ART method with proper reconstruction parameters provided better image quality than FBP method as well as conventional radiography. These results indicated that the ART method with optimal reconstruction parameters could improve image quality for nodule detection using the CDT system.

  11. Investigation o