WorldWideScience

Sample records for digital radiology systems

  1. Digital image information systems in radiology

    International Nuclear Information System (INIS)

    Greinacher, C.F.C.; Luetke, B.; Seufert, G.

    1987-01-01

    About 25% of all patient examinations are performed digitally in a today's radiological department. A computerized system is described that supports generation, transport, interpretation and archiving of digital radiological images (Picture Archiving and Communication System PACS). The technical features concerning image communication via local area networks, image storage on magnetic and optical media and digital workstations for image display and manipulation are described. A structured system architecture is introduced. It allows flexible adaption to individual organizations and minimizes the requirements of the communication network. (orig.) [de

  2. Digital radiology and digitally formatted image management systems

    International Nuclear Information System (INIS)

    Cox, G.G.; Dwyer, S.J. III; Templeton, A.W.

    1987-01-01

    The number of diagnostic examinations performed with digitally formatted imaging equipment is increasing. Digital general-purpose and fluoroscopic radiology systems are being clinically evaluated. Digitizing conventional x-ray films, such as mammograms, frequently improves the diagnostic quality of the images. The digitizing process with laser has also afforded the opportunity to document required spatial resolution for digital imaging and network systems. The use of digitally formatted image instrumentation imposes new requirements on the acquisition, display and manipulation, transmission, hard copy image recording, and archiving of diagnostic data. Networking of digitally formatted image data offers many advantages for managing digital information. This paper identifies and describes digital radiographic systems. Parameters required for designing and implementing a digital image management system are outlined. Spatial and contrast resolution requirements are identified. The key parameters include the amount of image data generated each working day, the retrieval rate of the generated data, the display hardware and software needed for interactive diagnosis display stations, the requirements for analog hard copy generation, and on-line and long-term archiving requirements. These image management systems are often called PACS (Picture Archiving and Communication Systems)

  3. Systems automated reporting of patient dose in digital radiology

    International Nuclear Information System (INIS)

    Collado Chamorro, P.; Sanz Freire, C. J.; Martinez Mirallas, O.; Tejada San Juan, S.; Lopez de Gammarra, M. S.

    2013-01-01

    It has developed a procedure automated reporting of doses to patients in Radiology. This procedure allows to save the time required of the data used to calculate the dose to patients by yields. Also saves the time spent in the transcription of these data for the realization of the necessary calculations. This system has been developed using open source software. The characteristics of the systems of digital radiography for the automation of procedures, in particular the registration of dose should benefit from patient. This procedure is validated and currently in use at our institution. (Author)

  4. Contribution to the study of integrated system design in digital imaging. Application to digital radiology

    International Nuclear Information System (INIS)

    Boy, M.

    1987-02-01

    In the first part of this work, we describe the hardware and software used to design integrated systems able to acquire, memorize, process and visualize 1024 x 1024 x 8 bits images. In the second part, we present and analyse the first realised prototype system which is a digital radiology one. After a technical and economical digital radiology study, we present the angiographic and tomographic results. In the third part, we indicate possible evolution of this system and we show how the adopted structure and developed hardware allow applications in various fields [fr

  5. Digital radiology and ultrasound

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.

    1991-01-01

    With the access to digital methods for handling and processing images in general, many medical imaging methods are becoming more effectively handled digitally. This applies in particular to basically digital techniques such as CT and MR but also now includes Nuclear Medicine (NM), Ultrasound (US) and a variety of radiological procedures such as Digital Subtraction Angiography (DSA) and Fluoroscopy (DF). The access to conventional projection images by stimulatable plates (CR) or by digitization of film makes all of radiology potentially accessible, and the management of such images by a network is the basic aim of Picture Archiving and Communication Systems (PACS). However, it is suggested that in order for such systems to be of greater value, that way in which such images are treated needs to change, that is, digital images can be used to derive additional clinical value by appropriate processing

  6. Digital radiology

    International Nuclear Information System (INIS)

    Dallas, W.J.

    1990-01-01

    Radiology is vital to the life-saving efforts of surgeons and other physicians, but precious time can be lost generating the images and transferring them to and from the operating room. Furthermore, hospitals are straining under the task of storing and managing the deluge of diagnostic films produced every year. A 300-bed hospital generates about 1 gigabyte (8 x 10 9 bits) of picture information every day and is legally bound to hold it for three to seven years--30 years in the case of silicosis or black lung disease, illnesses that may have relevance to future lawsuits. Consequently, hospital warehouses are filling with x-ray film and written reports that are important for analysis of patient histories, for comparison between patients, and for analyzing the progress of disease. Yet only a fraction of the information's potential is being used because access is so complicated. What is more, films are easily lost, erasing valuable medical histories

  7. Digital imaging in cardiovascular radiology

    International Nuclear Information System (INIS)

    Heintzen, P.H.; Brennecke, R.

    1983-01-01

    The present book contains 27 papers presented at an international symposium on digital imaging in cardiovascular radiology held in Kiel in 1982. The main themes were as follows. Introductory reviews, digital systems for X-ray video imaging, quantitative X-ray image analysis, and clinical applications. (MG)

  8. Total filmless digital radiology service

    International Nuclear Information System (INIS)

    Mun, S.K.; Goeringer, F.; Benson, H.; Horii, S.C.

    1989-01-01

    The completion of a comprehensive picture archiving and communication system (PACS) at Georgetown University Hospital has allowed us to identify a number of technical, administrative, personnel, and operational issues that will affect a total digital radiology service. With a hospital-wide digital imaging network system, computer simulation of communications and storage options, and economic modeling, we have developed a feasibility study and implementation strategy for the smooth transition to a nearly filmless radiology service over the next several years. This paper describes the technical and operational requirements for various database operations, workstations (used in diagnosis, review, and education), and communications. Site and installation planning, personnel training, and transition operations are discussed

  9. Digital imaging in diagnostic radiology

    International Nuclear Information System (INIS)

    Newell, J.D. Jr.; Kelsey, C.A.

    1990-01-01

    This monograph on digital imaging provides a basic overview of this field at the present time. This paper covers clinical application, including subtraction angiography; chest radiology; genitourinary, gastrointestinal, and breast radiology; and teleradiology. The chest section also includes an explanation of multiple beam equalization radiography. The remaining chapters discuss some of the technical aspects of digital radiology. It includes the basic technology of digital radiography, image compression, and reconstruction information on the economics of digital radiography

  10. Digital Radiology Image Learning Library

    International Nuclear Information System (INIS)

    Arenson, R.L.; Greenes, R.; Allman, R.; Swett, H.

    1989-01-01

    The Digital Radiology Image Learning Library (DRILL) is designed as an interactive teaching tool targeted to the radiologic community. The DRILL pilot comprises a comprehensive mammographic information base consisting of factual data in a relational database, an extensive knowledge base in semantic nets and high-resolution images. A flexible query module permits the user to browse and retrieve examination data, case discussions, and related images. Other applications, including expert systems, instructional programs, and skill building exercises, can be accessed through well-defined software constructs

  11. Dose audit for patients undergoing two common radiography examinations with digital radiology systems

    Science.gov (United States)

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    PURPOSE We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. MATERIALS AND METHODS Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. RESULTS The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. CONCLUSION This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey. PMID:24317331

  12. Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

    Science.gov (United States)

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.

  13. Digital radiology. Clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, F; Smathers, R L

    1985-01-01

    The authors report the experience achieved ad the Stanford University (USA) with a digital radiography system which allows the digitization of the film and of the images collected with photostimulable phophors. The phophor is essentially an intensifying screen where a latent image is stored after exposure to X-rays and is extracted by a laser scanning. The images collected with the digitized film and with the phophor (chest, breast, bone) have been analyzed. The digitized film offers potential diagnostic advantages over the conventional film, because of the contrast manipulation and many other processing options. The possibility to recover the information of overexposed films appears very attractive. The photostimulable phophors allow to get good quality images, with a consistent reduction of dose and costs. These plates offer the possibility, in the next future, to replace the conventional screen-film systems.

  14. 75 FR 68200 - Medical Devices; Radiology Devices; Reclassification of Full-Field Digital Mammography System

    Science.gov (United States)

    2010-11-05

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration 21 CFR Part 892 [Docket No. FDA-2008-N-0273] Medical Devices; Radiology Devices; Reclassification of Full- Field Digital... and Drugs, 21 CFR part 892 is amended as follows: PART 892--RADIOLOGY DEVICES 0 1. The authority...

  15. Online patient dosimetry and an image quality audit system in digital radiology

    International Nuclear Information System (INIS)

    Fernandez, J. M.; Vano, E.; Ten, J. I.; Prieto, C.; Martinez, D.

    2006-01-01

    The present work describes an online patient dosimetry and an image quality audit system in digital radiology. the system allows auditing of different parameters depending on contents of DICOM (Digital Imaging and Communication in Medicine) header. For the patient dosimetry audit, current mean values of entrance surface dose (ESD) were compared with local and national reference values (RVs) for the specific examination type evaluated. Mean values exceeding the RV trigger an alarm signal and then an evaluation of the technical parameters, operational practice and image quality starts, using data available in the DICOM header to derive any abnormal settings or performance to obtain the image. the X-ray tube output for different kVp values is measured periodically, allowing for the automatic calculation of the ESD. The system also allows for image quality audit linking it with the dose imparted and other technical parameters if the alarm condition if produced. Results and advantages derived from this online quality control are discussed. (Author) 5 refs

  16. Managing patient dose in digital radiology

    International Nuclear Information System (INIS)

    2014-01-01

    Digital techniques have the potential to improve the practice of radiology but they also risk the overuse of radiation. The main advantages of digital imaging, i.e. wide dynamic range, post processing, multiple viewing options, and electronic transfer and archiving possibilities, are clear but overexposures can occur without an adverse impact on image quality. In conventional radiography, excessive exposure produces a black film. In digital systems, good images are obtained for a large range of doses. It is very easy to obtain (and delete) images with digital fluoroscopy systems, and there may be a tendency to obtain more images than necessary. In digital radiology, higher patient dose usually means improved image quality, so a tendency to use higher patient doses than necessary could occur. Different medical imaging tasks require different levels of image quality, and doses that have no additional benefit for the clinical purpose should be avoided. Image quality can be compromised by inappropriate levels of data compression and/or post processing techniques. All these new challenges should be part of the optimisation process and should be included in clinical and technical protocols. Local diagnostic reference levels should be re-evaluated for digital imaging, and patient dose parameters should be displayed at the operator console. Frequent patient dose audits should occur when digital techniques are introduced. Training in the management of image quality and patient dose in digital radiology is necessary. Digital radiology will involve new regulations and invoke new challenges for practitioners. As digital images are easier to obtain and transmit, the justification criteria should be reinforced. Commissioning of digital systems should involve clinical specialists, medical physicists, and radiographers to ensure that imaging capability and radiation dose management are integrated. Quality control requires new procedures and protocols (visualisation, transmission

  17. Comparison between a digital scanning system and a conventional screen film system in the full spine radiological procedure in pediatrics

    International Nuclear Information System (INIS)

    Espana, M. L.; Gomez, G.; Romero, A.; Minambres, A.; Albi, G.; Floriano, A.; Rodirguez, A.; Lopez Franco, P.

    2004-01-01

    To compare from both dosimetry and image quality standpoints, a digital scanning system with a conventional screen film system, in the full spine radiological procedure. The standard patient is considered to be 12 years old, and a sample of forty patients referred for full spine radiological procedure has been studied. Gonad shielding has been used in all the patients, and its efficiency has been evaluated. Dosimetric study includes Kerma-area product, and thorax and gonad entrance surface dose. Kerma area product has been measured using a transmission camera, and for entrance surface dose estimation both thermoluminescent dosemeter LiF: Mg, Cu, P and LiF: Mg, Ti have been utilized. Three radiologists have evaluated the image quality according to the degree of fulfilment of the image quality criteria. (Author) 22 refs

  18. Design, Development and Optimization of a Low Cost System for Digital Industrial Radiology

    International Nuclear Information System (INIS)

    2013-01-01

    regional training courses in which participants from Member States were given training in DIR techniques. The IAEA also supported establishing facilities for DIR techniques in some Member States. Realizing the need for easy construction and assembly of a low cost, more economically viable system for DIR technology, the IAEA conducted a coordinated research project (CRP) during 2007-2010 for research and development in the field of digital radiology, with the participation of 12 Member State laboratories. The current publication on design, development and optimization of a low cost DIR system is based on the findings of this CRP and inputs from other experts. The report provides guidelines to enable interested Member States to build their own DIR system in an affordable manner

  19. Functional integration of digital radiologic equipment

    International Nuclear Information System (INIS)

    Agnifili, A.; DiStefano, G.; Salcito, G.; Passariello, R.

    1989-01-01

    This paper reports on a pilot project for the functional integration of digital radiologic equipment. Four different systems (a digital subtraction angiography unit, a DF unit, a computer radiography prototype, and a film digitizer) were connected with a link in an Ethernet LAN.ACR-NEMA standards were used to process the images of the different units in the same way. The central computer manages the long-term optical archive and the film laser printer. Some graphic workstations are connected to the picture archiving and communications system, which allows fast retrieval and processing of the images. Patients; data are acquired through the RIS and stored together with the images

  20. The National Institutes of Health Clinical Center Digital Imaging Network, Picture Archival and Communication System, and Radiology Information System.

    Science.gov (United States)

    Goldszal, A F; Brown, G K; McDonald, H J; Vucich, J J; Staab, E V

    2001-06-01

    In this work, we describe the digital imaging network (DIN), picture archival and communication system (PACS), and radiology information system (RIS) currently being implemented at the Clinical Center, National Institutes of Health (NIH). These systems are presently in clinical operation. The DIN is a redundant meshed network designed to address gigabit density and expected high bandwidth requirements for image transfer and server aggregation. The PACS projected workload is 5.0 TB of new imaging data per year. Its architecture consists of a central, high-throughput Digital Imaging and Communications in Medicine (DICOM) data repository and distributed redundant array of inexpensive disks (RAID) servers employing fiber-channel technology for immediate delivery of imaging data. On demand distribution of images and reports to clinicians and researchers is accomplished via a clustered web server. The RIS follows a client-server model and provides tools to order exams, schedule resources, retrieve and review results, and generate management reports. The RIS-hospital information system (HIS) interfaces include admissions, discharges, and transfers (ATDs)/demographics, orders, appointment notifications, doctors update, and results.

  1. Advantages of digital imaging for radiological diagnostic

    International Nuclear Information System (INIS)

    Trapero, M. A.; Gonzalez, S.; Albillos, J. C.; Martel, J.; Rebollo, M.

    2006-01-01

    The advantages and limitations of radiological digital images in comparison with analogic ones are analyzed. We discuss three main topics: acquisition, post-procedure manipulation, and visualization, archive and communication. Digital acquisition with computed radiology systems present a global sensitivity very close to conventional film for diagnostic purposes. However, flat panel digital systems seems to achieve some advantages in particular clinical situations. A critical issue is the radiation dose-reduction that can be accomplished without reducing image quality nor diagnostic exactitude. The post-procedure manipulation allows, particularly in multiplanar modalities like CT or MR, to extract all implicit diagnostic information in the images: Main procedures are multiplanar and three-dimensional reformations, dynamic acquisitions, functional studies and image fusion. The use of PACS for visualization, archive and communication of images, improves the effectiveness and the efficiency of the workflow, allows a more comfortable diagnosis for the radiologist and gives way to improvements in the communication of images, allowing tele consulting and the tele radiology. (Author) 6 refs

  2. Establishing diagnostic reference levels in digital radiology

    International Nuclear Information System (INIS)

    Bana, Remy Wilson

    2016-04-01

    Medical application of radiation has gained wider study since diagnostic radiology plays a very important role in modern medicine. The need of the service seems to increase since the invention of digital radiology as a new technology that promises greater accuracy while minimizing patient dose. However, it is not exempted in the harmonization of doses delivered to the patient undergoing same radiologic examination in different institutions either regional or nationwide. The objective of this project was to review the establishment of Diagnostic Reference Levels (DRLs) in digital radiology at National level with the aim to reduce patient dose while maintaining appropriate image quality. A general discussion on digital radiology has been presented focusing on the optimization of patient dose as well as dosimetric quantities used for the establishment of DRLs. Recommendations have been provided for Rwanda to initiate steps to establish National Diagnostic Reference Levels for common procedures in digital radiology. (au)

  3. Systems automated reporting of patient dose in digital radiology; Sistema automatizado para generacion de informes de dosis a paciente en radiologia digital

    Energy Technology Data Exchange (ETDEWEB)

    Collado Chamorro, P.; Sanz Freire, C. J.; Martinez Mirallas, O.; Tejada San Juan, S.; Lopez de Gammarra, M. S.

    2013-07-01

    It has developed a procedure automated reporting of doses to patients in Radiology. This procedure allows to save the time required of the data used to calculate the dose to patients by yields. Also saves the time spent in the transcription of these data for the realization of the necessary calculations. This system has been developed using open source software. The characteristics of the systems of digital radiography for the automation of procedures, in particular the registration of dose should benefit from patient. This procedure is validated and currently in use at our institution. (Author)

  4. Radiological digital teaching file development: an overview

    International Nuclear Information System (INIS)

    Scarsbrook, A.F.; Foley, P.T.; Perriss, R.W.; Graham, R.N.J.

    2005-01-01

    Radiologists are collectors of interesting films for teaching purposes or for use in presentations and publications. Traditionally, hard copies of films have been stored in an organized fashion, usually in a filing cabinet or film library. This system has inherent limitations, such as the physical space required. Many of the shortcomings can be circumvented by development of an electronic teaching file. Whereas the implementation of an institutional radiological digital image database can require significant developmental effort and programming expertise, there are a number of web-based solutions which are freely available and can be relatively easily employed to establish a contemporary electronic image library. This article will review the various options and discuss the process of developing a digital image database

  5. Possibilities and limits of digital industrial radiology: the new high contrast sensitivity technique - Examples and system theoretical analysis

    International Nuclear Information System (INIS)

    Zscherpel, U.; Ewert, U.; Bavendiek, K.

    2007-01-01

    During the last years more and more reports about film replacement techniques are published using different ways to prove the required and obtained image quality. The motivation is usually cost reduction due to shorter exposure times and lower storage costs, smaller space requirements and elimination of chemical processing inclusive associated waste handling and disposal. There are no other publications known, which explore the upper limits of image quality achievable by the new digital techniques. This is important for inspection of safety relevant and high risk parts, as e.g. in nuclear or aerospace industries. A new calibration and measurement procedure for digital detector arrays (DDA) was explored to obtain the maximum signal/noise ratio achievable with DDAs. This procedure yields a contrast sensitivity which allows distinguishing wall thickness changes of up to 1/1000 of the penetrated material thickness. Standard film radiography using NDT film systems (with and without lead screens) achieves a wall thickness contrast which is not better than 1/100 even with the best film system class (class 'C1' according to EN 584-1 or 'special' according to ASTM E 1815). Computed Radiography (CR) using phosphor imaging plates is a true film replacement technique without enhancement of the image quality compared to NDT film systems. The comparison is based on parameter studies which measure signal/noise ratios and determine the basic spatial resolution as well as a comparison of radiological images with fine flaws. (authors)

  6. Radiology systems architecture.

    Science.gov (United States)

    Deibel, S R; Greenes, R A

    1996-05-01

    This article focuses on the software requirements for enterprise integration in radiology. The needs of a future radiology systems architecture are examined, both at a concrete functional level and at an abstract system-properties level. A component-based approach to software development is described and is validated in the context of each of the abstract system requirements for future radiology computing environments.

  7. Online patient dosimetry and an image quality audit system in digital radiology; Auditoria en tiempo real de dosis a los pacientes y claidad de imagen en radiologia digital

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, J. M.; Vano, E.; Ten, J. I.; Prieto, C.; Martinez, D.

    2006-07-01

    The present work describes an online patient dosimetry and an image quality audit system in digital radiology. the system allows auditing of different parameters depending on contents of DICOM (Digital Imaging and Communication in Medicine) header. For the patient dosimetry audit, current mean values of entrance surface dose (ESD) were compared with local and national reference values (RVs) for the specific examination type evaluated. Mean values exceeding the RV trigger an alarm signal and then an evaluation of the technical parameters, operational practice and image quality starts, using data available in the DICOM header to derive any abnormal settings or performance to obtain the image. the X-ray tube output for different kVp values is measured periodically, allowing for the automatic calculation of the ESD. The system also allows for image quality audit linking it with the dose imparted and other technical parameters if the alarm condition if produced. Results and advantages derived from this online quality control are discussed. (Author) 5 refs.

  8. A digital library of radiology images.

    Science.gov (United States)

    Kahn, Charles E

    2006-01-01

    A web-based virtual library of peer-reviewed radiological images was created for use in education and clinical decision support. Images were obtained from open-access content of five online radiology journals and one e-learning web site. Figure captions were indexed by Medical Subject Heading (MeSH) codes, imaging modality, and patient age and sex. This digital library provides a new, valuable online resource.

  9. Development of a networked four-million-pixel pathological and radiological digital image presentation system and its application to medical conferences

    Science.gov (United States)

    Sakano, Toshikazu; Furukawa, Isao; Okumura, Akira; Yamaguchi, Takahiro; Fujii, Tetsuro; Ono, Sadayasu; Suzuki, Junji; Matsuya, Shoji; Ishihara, Teruo

    2001-08-01

    The wide spread of digital technology in the medical field has led to a demand for the high-quality, high-speed, and user-friendly digital image presentation system in the daily medical conferences. To fulfill this demand, we developed a presentation system for radiological and pathological images. It is composed of a super-high-definition (SHD) imaging system, a radiological image database (R-DB), a pathological image database (P-DB), and the network interconnecting these three. The R-DB consists of a 270GB RAID, a database server workstation, and a film digitizer. The P-DB includes an optical microscope, a four-million-pixel digital camera, a 90GB RAID, and a database server workstation. A 100Mbps Ethernet LAN interconnects all the sub-systems. The Web-based system operation software was developed for easy operation. We installed the whole system in NTT East Kanto Hospital to evaluate it in the weekly case conferences. The SHD system could display digital full-color images of 2048 x 2048 pixels on a 28-inch CRT monitor. The doctors evaluated the image quality and size, and found them applicable to the actual medical diagnosis. They also appreciated short image switching time that contributed to smooth presentation. Thus, we confirmed that its characteristics met the requirements.

  10. Data compression with applications to digital radiology

    International Nuclear Information System (INIS)

    Elnahas, S.E.

    1985-01-01

    The structure of arithmetic codes is defined in terms of source parsing trees. The theoretical derivations of algorithms for the construction of optimal and sub-optimal structures are presented. The software simulation results demonstrate how arithmetic coding out performs variable-length to variable-length coding. Linear predictive coding is presented for the compression of digital diagnostic images from several imaging modalities including computed tomography, nuclear medicine, ultrasound, and magnetic resonance imaging. The problem of designing optimal predictors is formulated and alternative solutions are discussed. The results indicate that noiseless compression factors between 1.7 and 7.4 can be achieved. With nonlinear predictive coding, noisy and noiseless compression techniques are combined in a novel way that may have a potential impact on picture archiving and communication systems in radiology. Adaptive fast discrete cosine transform coding systems are used as nonlinear block predictors, and optimal delta modulation systems are used as nonlinear sequential predictors. The off-line storage requirements for archiving diagnostic images are reasonably reduced by the nonlinear block predictive coding. The online performance, however, seems to be bounded by that of the linear systems. The subjective quality of image imperfect reproductions from the cosine transform coding is promising and prompts future research on the compression of diagnostic images by transform coding systems and the clinical evaluation of these systems

  11. ASTM reference radiologic digital image standards

    International Nuclear Information System (INIS)

    Wysnewski, R.; Wysnewski, D.

    1996-01-01

    ASTM Reference Radiographs have been essential in defining industry's material defect grade levels for many years. ASTM Reference Radiographs are used extensively as even the American Society for Metals Nondestructive Inspection and Quality Control Metals Handbook, Volume 11, eighth edition refers to ASTM Standard Reference Radiographs. The recently published E 1648 Standard Reference Radiographs for Examination of Aluminum Fusion Welds is a prime example of the on-going need for these references. To date, 14 Standard Reference Radiographs have been published to characterize material defects. Standard Reference Radiographs do not adequately address film-less radiologic methods. There are differences in mediums to content with. On a computer CRT defect indications appear differently when compared to indications viewed in a radiograph on a view box. Industry that uses non-film radiologic methods of inspection can be burdened with additional time and money developing internal standard reference radiologic images. These references may be deemed necessary for grading levels of product defects. Because there are no ASTM Standard Reference Radiologic data files for addressing this need in the industry, the authors of this paper suggested implementing a method for their creation under ASTM supervision. ASTM can assure continuity to those users making the transition from analog radiographic images to digital image data by swiftly addressing the requirements for reference digital image standards. The current status and possible future activities regarding a method to create digital data files is presented in this paper summary

  12. Digital systems to acquire radiological imaging. Characteristics and quality control; Sistemas digitales de adquisicion de imagenes radiograficas. Caracteristicas y Control de Calidad

    Energy Technology Data Exchange (ETDEWEB)

    Torres Cabrera, R.; Hernando Gonzalez, I.

    2006-07-01

    Due to its special characteristics, quality control in digital radiographic systems is very important, even more than in conventional film-screen systems. Differences between digital and analogical images,a in terms of dynamics range, spatial and contrast resolution, and the flexibility of data post-processing require some actions to maintain clinical images in an optimum quality level. Revision 1 of the Spanish Protocol of Quality Control in Diagnostic Radiology includes a chapter dedicated to the quality control of these digital systems for the acquisition of radiographic images. In this paper the different parameters for quality control procedures are described. Also some difficulties to be concerned about (absence of levels of tolerance, access to the raw-data images and related information, availability of use anthropomorphic phantoms, etc, etc) are noted, as well as the most significant aspects of the differences in relation to the ana logical systems. (Author) 15 refs.

  13. Advanced radiology information system.

    Science.gov (United States)

    Kolovou, L; Vatousi, M; Lymperopoulos, D; Koukias, M

    2005-01-01

    The innovative features of an advanced Radiology Information System (RIS) are presented in this paper. The interoperability of RIS with the other Intra-hospital Information Systems that interacts with, dealing with the compatibility and open architecture issues, are accomplished by two novel mechanisms [1]. The first one is the particular message handling system that is applied for the exchange of information, according to the Health Level Seven (HL7) protocol's specifications and serves the transfer of medical and administrative data among the RIS applications and data store unit. The same mechanism allows the secure and HL7-compatible interactions with the Hospital Information System (HIS) too. The second one implements the translation of information between the formats that HL7 and Digital Imaging and Communication in Medicine (DICOM) protocols specify, providing the communication between RIS and Picture and Archive Communication System (PACS). The whole structure ensures the automation of the every-day procedures that the ;medical protocol' specifies and provides its services through a friendly and easy to manage graphical user interface.

  14. Device for direct digitized radiology of small objects

    International Nuclear Information System (INIS)

    Thomas, G.; Favier, C.; Brebant, C.; Mogavero, R.

    1983-06-01

    A radiological device has been developed to obtain direct digitized views with a large integration time. A micro computer system with programs specially developed for the automatic materials defects evaluation is used. Some results concerning the weldings of electro-nuclear fuel pins are presented here [fr

  15. Digital imaging in conventional diagnostic radiology: status and trends

    International Nuclear Information System (INIS)

    Pfeiler, M.; Marhoff, P.; Schipper, P.

    1984-01-01

    Digital techniques, i.e. techniques using microcomputers of minicomputers, are getting increasingly common in so-called conventional radiography. These nonreconstructive techniques are referred to here as 'digital, direct-imaging radiography' in order to contrast them with the reconstructive techniques of computerized tomography. Digitalisation of imaging and image processing operation and control will change the jobs of the radiologist and radiological assistants in such manner that only X-ray units with film-foil systems or with X-ray image intensification should be classified as conventional systems. Digital and conventional systems differ in that digital techniques imply the possibility of establishing data pools which may eventually be developed into a digital image interconnection and archiving system. The authors first describe the general system in which the digital imaging systems must be integrated on a medium-term and long-term basis and then proceed to discuss digital imaging and image processing in some more detail. (orig./WU) [de

  16. Intraoral radiology in general dental practices - a comparison of digital and film-based X-ray systems with regard to radiation protection and dose reduction.

    Science.gov (United States)

    Anissi, H D; Geibel, M A

    2014-08-01

    The purpose of this study was to gain insight into the distribution and application of digital intraoral radiographic techniques within general dental practices and to compare these with film-based systems in terms of patient dose reduction. 1100 questionnaires were handed out to general dental practitioners. Data was analyzed with respect to the type of system by using descriptive statistics and nonparametric tests, i.e. Kruskal-Wallis, Mann-Whitney and chi-square test (SPSS 20). 64% of the questioned dentists still use film-based radiology, 23% utilize storage phosphor plate (SPP) systems and 13% use a charge-coupled device (CCD). A strong correlation between the number of dentists working in a practice and the use of digital dental imaging was observed. Almost 3/4 of the film users work with E- or F-speed film. 45% of them refuse to change to a digital system. The use of lead aprons was popular, while only a minority preferred thyroid shields and rectangular collimators. A fourfold reduction of exposure time from D-speed film to CCD systems was observed. Due to detector size and positioning errors, users of CCD systems take significantly more single-tooth radiographs in total. Considering the number of radiographs per patient, there is only a slight tendency towards more X-rays with CCD systems. Up to image generation, digital systems seem to be as or even more difficult to handle than film-based systems, while their handling was favored after radiographic exposure. Despite a slight increase of radiographs taken with CCD systems, there is a significant dosage reduction. Corresponding to the decrease in exposure time, the patient dose for SPP systems is reduced to one half compared to film. The main issues in CCD technology are positioning errors and the size of the X-ray detectors which are difficult to eliminate. The usage of radiation protection measures still needs to be improved. ► Responsible use of digital intraoral radiology results in a significant

  17. [Conventional radiology, digital radiology with photostimulable phosphor, laser digitalization of thoracic radiographic films at the bedside. A comparative study].

    Science.gov (United States)

    Miceli, M; Stamati, R; Burci, P; Guidarelli, G; Sartoni Galloni, S

    1992-10-01

    The bedside chest images obtained with conventional radiology and with "on line" and "off line" digital modalities were compared to evaluate the respective capabilities in visualizing chest anatomical structures. Seventy patients were submitted to bedside chest examinations with a portable unit; both a conventional film and a digital system (PCR Graphics 1, Philips) with photostimulable phosphor imaging plate were fitted in the radiographic cassette. The former was digitized using an "off line" laser beam unit (FD 2000, Dupont); the latter was subsequently postprocessed by modifying contrast, optical density and spatial frequencies. Thus, 4 different viewing modalities were obtained for each examination: a) conventional radiography; b) standard digital radiography; c) postprocessed digital radiography; d) digitized conventional radiography. Detectability rates of chest anatomical structures were analyzed by 4 independent radiologists on the different images and expressed by a score 1-4. The values were always higher with digital modalities than with the conventional one and the differences were statistically significant (Student's t-test modified by Bonferroni). In particular, the greatest difference was found between c) and a) in retrocardiac lung parenchyma and in skeletal structures, in favour of c). Concerning the comparative adequacy of the various digital modalities, higher detectability rates of chest anatomical structures were obtained with c), but also with b), than with d).

  18. Standard guide for digital detector array radiology

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This standard is a user guide, which is intended to serve as a tutorial for selection and use of various digital detector array systems nominally composed of the detector array and an imaging system to perform digital radiography. This guide also serves as an in-detail reference for the following standards: Practices E2597, , and E2737. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  19. Use of digital speech recognition in diagnostics radiology

    International Nuclear Information System (INIS)

    Arndt, H.; Stockheim, D.; Mutze, S.; Petersein, J.; Gregor, P.; Hamm, B.

    1999-01-01

    Purpose: Applicability and benefits of digital speech recognition in diagnostic radiology were tested using the speech recognition system SP 6000. Methods: The speech recognition system SP 6000 was integrated into the network of the institute and connected to the existing Radiological Information System (RIS). Three subjects used this system for writing 2305 findings from dictation. After the recognition process the date, length of dictation, time required for checking/correction, kind of examination and error rate were recorded for every dictation. With the same subjects, a correlation was performed with 625 conventionally written finding. Results: After an 1-hour initial training the average error rates were 8.4 to 13.3%. The first adaptation of the speech recognition system (after nine days) decreased the average error rates to 2.4 to 10.7% due to the ability of the program to learn. The 2 nd and 3 rd adaptations resulted only in small changes of the error rate. An individual comparison of the error rate developments in the same kind of investigation showed the relative independence of the error rate on the individual user. Conclusion: The results show that the speech recognition system SP 6000 can be evaluated as an advantageous alternative for quickly recording radiological findings. A comparison between manually writing and dictating the findings verifies the individual differences of the writing speeds and shows the advantage of the application of voice recognition when faced with normal keyboard performance. (orig.) [de

  20. Intraoral radiology in general dental practices. A comparison of digital and film-based X-ray systems with regard to radiation protection and dose reduction

    Energy Technology Data Exchange (ETDEWEB)

    Anissi, H.D. [Ulm Univ. (Germany). Dentistry; Geibel, M.A. [Ulm Univ. (Germany). Dept. of Dentomaxillofacial Surgery

    2014-08-15

    Purpose: The purpose of this study was to gain insight into the distribution and application of digital intraoral radiographic techniques within general dental practices and to compare these with film-based systems in terms of patient dose reduction. Materials and Methods: 1100 questionnaires were handed out to general dental practitioners. Data was analyzed with respect to the type of system by using descriptive statistics and nonparametric tests, i.e. Kruskal-Wallis, Mann-Whitney and chi-square test (SPSS 20). Results: 64% of the questioned dentists still use film-based radiology, 23% utilize storage phosphor plate (SPP) systems and 13% use a charge-coupled device (CCD). A strong correlation between the number of dentists working in a practice and the use of digital dental imaging was observed. Almost 3/4 of the film users work with E- or F-speed film. 45% of them refuse to change to a digital system. The use of lead aprons was popular, while only a minority preferred thyroid shields and rectangular collimators. A fourfold reduction of exposure time from D-speed film to CCD systems was observed. Due to detector size and positioning errors, users of CCD systems take significantly more single-tooth radiographs in total. Considering the number of radiographs per patient, there is only a slight tendency towards more X-rays with CCD systems. Up to image generation, digital systems seem to be as or even more difficult to handle than film-based systems, while their handling was favored after radiographic exposure. Conclusion: Despite a slight increase of radiographs taken with CCD systems, there is a significant dosage reduction. Corresponding to the decrease in exposure time, the patient dose for SPP systems is reduced to one half compared to film. The main issues in CCD technology are positioning errors and the size of the X-ray detectors which are difficult to eliminate. The usage of radiation protection measures still needs to be improved. (orig.)

  1. Intraoral radiology in general dental practices. A comparison of digital and film-based X-ray systems with regard to radiation protection and dose reduction

    International Nuclear Information System (INIS)

    Anissi, H.D.; Geibel, M.A.

    2014-01-01

    Purpose: The purpose of this study was to gain insight into the distribution and application of digital intraoral radiographic techniques within general dental practices and to compare these with film-based systems in terms of patient dose reduction. Materials and Methods: 1100 questionnaires were handed out to general dental practitioners. Data was analyzed with respect to the type of system by using descriptive statistics and nonparametric tests, i.e. Kruskal-Wallis, Mann-Whitney and chi-square test (SPSS 20). Results: 64% of the questioned dentists still use film-based radiology, 23% utilize storage phosphor plate (SPP) systems and 13% use a charge-coupled device (CCD). A strong correlation between the number of dentists working in a practice and the use of digital dental imaging was observed. Almost 3/4 of the film users work with E- or F-speed film. 45% of them refuse to change to a digital system. The use of lead aprons was popular, while only a minority preferred thyroid shields and rectangular collimators. A fourfold reduction of exposure time from D-speed film to CCD systems was observed. Due to detector size and positioning errors, users of CCD systems take significantly more single-tooth radiographs in total. Considering the number of radiographs per patient, there is only a slight tendency towards more X-rays with CCD systems. Up to image generation, digital systems seem to be as or even more difficult to handle than film-based systems, while their handling was favored after radiographic exposure. Conclusion: Despite a slight increase of radiographs taken with CCD systems, there is a significant dosage reduction. Corresponding to the decrease in exposure time, the patient dose for SPP systems is reduced to one half compared to film. The main issues in CCD technology are positioning errors and the size of the X-ray detectors which are difficult to eliminate. The usage of radiation protection measures still needs to be improved. (orig.)

  2. Dose reference levels in Spanish intraoral dental radiology: stabilisation of the incorporation of digital systems in dental clinical practices

    International Nuclear Information System (INIS)

    Alcaraz, M.; Velasco, F.; Olivares, A.; Velasco, E.; Canteras, M.

    2016-01-01

    A total of 34 044 official quality assurance reports in dental radiodiagnostic surgery from 16 regions of Spain, compiled from 2002 to 2014, were studied in order to determine the progress of diagnostic reference levels (DRLs) for obtaining diagnostic images under normal conditions for clinical practice in Spanish dental clinics. A DRL of 2.8 mGy was set in 2014, which represents a 41.7 % decrease compared with that of 2002 (4.8 mGy). Over the same time period, the mean dose fell by 55.2 %. However, over the last 3 y, the stabilisation of the mean dose administered to patients has been observed with only a 6.7 % reduction in DRLs, which corresponds to the stabilisation of dental radiodiagnostic surgery on replacing the use of radiographic film with digital imaging systems. (authors)

  3. [Digital thoracic radiology: devices, image processing, limits].

    Science.gov (United States)

    Frija, J; de Géry, S; Lallouet, F; Guermazi, A; Zagdanski, A M; De Kerviler, E

    2001-09-01

    In a first part, the different techniques of digital thoracic radiography are described. Since computed radiography with phosphore plates are the most commercialized it is more emphasized. But the other detectors are also described, as the drum coated with selenium and the direct digital radiography with selenium detectors. The other detectors are also studied in particular indirect flat panels detectors and the system with four high resolution CCD cameras. In a second step the most important image processing are discussed: the gradation curves, the unsharp mask processing, the system MUSICA, the dynamic range compression or reduction, the soustraction with dual energy. In the last part the advantages and the drawbacks of computed thoracic radiography are emphasized. The most important are the almost constant good quality of the pictures and the possibilities of image processing.

  4. Radiology trainer. Musculoskeletal system

    International Nuclear Information System (INIS)

    Staebler, A.; Erlt-Wagner, B.

    2006-01-01

    This book enables students to simulate examinations. The Radiology Trainer series comprises the whole knowledge of radiology in the form of case studies for self-testing. It is based on the best-sorted German-language collection of radiological examinations of all organ regions. Step by step, radiological knowledge is trained in order to make diagnoses more efficient. The book series ensures optimal preparation for the final medical examinations and is also a valuable tool for practical training. (orig.)

  5. Spatial resolution requirements for digital radiology

    International Nuclear Information System (INIS)

    Seeley, G.W.; Dallas, W.J.; Guillian, J.; Ovitt, T.; Standen, J.

    1990-01-01

    This paper describes research to define the needed spatial resolution for maintaining diagnostic accuracy in digital systems. Posteroanterior images from 30 normal and 30 abnormal studies of patients with various stages of interstitial disease were digitized at 51 p/mm with 12 bits of gray level and then processed in a computer to reduce spatial resolution from 5.0 to 2.5, 1.875, and in 1.25 Ip/mm. A Kodak laser writer using a LUT devised to ensure the copies had equal densities to those measured from the original images was used to write the images back to film. These film images were then shown to radiologists (one resolution level per radiologist). They were asked to give their diagnosis and certainty for each image (receiver operating characteristic [ROC] paradigm) and also to rate each image on overall spatial and contrast resolution as well as the visibility of seven diagnostically important structures

  6. A review of digital radiological methods

    International Nuclear Information System (INIS)

    Halmshaw, R.; Ridyard, J.N.A.

    1990-01-01

    The development of more powerful, cost-effective computer systems in recent years has enabled digital radiography to become a reality. This is not only for adding on to real-time fluoroscopic systems as a useful way of averaging image data to reduce noise and perform various manipulation functions, but also the more powerful wide dynamic range discrete-detector systems where one can extract far more information from an X-ray exposure than was formerly possible. This type of detector is essential for computer tomography and back-scatter tomography, but when applied to classical 2-dimensional images results in some unique advantages not achievable with film. These newer systems are capable of matching or exceeding film performance, especially at high X-ray energies. (author)

  7. Report generation using digital speech recognition in radiology

    International Nuclear Information System (INIS)

    Vorbeck, F.; Ba-Ssalamah, A.; Kettenbach, J.; Huebsch, P.

    2000-01-01

    The aim of this study was to evaluate whether the use of a digital continuous speech recognition (CSR) in the field of radiology could lead to relevant time savings in generating a report. A CSR system (SP6000, Philips, Eindhoven, The Netherlands) for German was used to transform fluently spoken sentences into text. Two radiologists dictated a total of 450 reports on five radiological topics. Two typists edited those reports by means of conventional typing using a text editor (WinWord 6.0, Microsoft, Redmond, Wash.) installed on an IBM-compatible personal computer (PC). The same reports were generated using the CSR system and the performance of both systems was then evaluated by comparing the time needed to generate the reports and the error rates of both systems. In addition, the error rate of the CSR system and the time needed to create the reports was evaluated. The mean error rate for the CSR system was 5.5 %, and the mean error rate for conventional typing was 0.4 %. Reports edited with the CSR, on average, were generated 19 % faster compared with the conventional text-editing method. However, the amount of error rates and time savings were different and depended on topics, speakers, and typists. Using CSR the maximum time saving achieved was 28 % for the topic sonography. The CSR system was never slower, under any circumstances, than conventional typing on a PC. When compared with a conventional manual typing method, the CSR system proved to be useful in a clinical setting and saved time in generating radiological reports. The amount of time saved, however, greatly depended on the performance of the typist, the speaker, and on stored vocabulary provided by the CSR system. (orig.)

  8. Standard practice for radiological examination using digital detector arrays

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice establishes the minimum requirements for radiological examination for metallic and nonmetallic material using a digital detector array (DDA) system. 1.2 The requirements in this practice are intended to control the quality of radiologic images and are not intended to establish acceptance criteria for parts or materials. 1.3 This practice covers the radiologic examination with DDAs including DDAs described in Practice E2597 such as a device that contains a photoconductor attached to a Thin Film Transistor (TFT) read out structure, a device that has a phosphor coupled directly to an amorphous silicon read-out structure, and devices where a phosphor is coupled to a CMOS (Complementary metal–oxide–semiconductor) array, a Linear Detector Array (LDA) or a CCD (charge coupled device) crystalline silicon read-out structure. 1.4 The DDA shall be selected for an NDT application based on knowledge of the technology described in Guide , and of the selected DDA properties provided by the manufactu...

  9. Use of film digitizers to assist radiology image management

    Science.gov (United States)

    Honeyman-Buck, Janice C.; Frost, Meryll M.; Staab, Edward V.

    1996-05-01

    The purpose of this development effort was to evaluate the possibility of using digital technologies to solve image management problems in the Department of Radiology at the University of Florida. The three problem areas investigated were local interpretation of images produced in remote locations, distribution of images to areas outside of radiology, and film handling. In all cases the use of a laser film digitizer interfaced to an existing Picture Archiving and Communication System (PACS) was investigated as a solution to the problem. In each case the volume of studies involved were evaluated to estimate the impact of the solution on the network, archive, and workstations. Communications were stressed in the analysis of the needs for all image transmission. The operational aspects of the solution were examined to determine the needs for training, service, and maintenance. The remote sites requiring local interpretation included were a rural hospital needing coverage for after hours studies, the University of Florida student infirmary, and the emergency room. Distribution of images to the intensive care units was studied to improve image access and patient care. Handling of films originating from remote sites and those requiring urgent reporting were evaluated to improve management functions. The results of our analysis and the decisions that were made based on the analysis are described below. In the cases where systems were installed, a description of the system and its integration into the PACS system is included. For all three problem areas, although we could move images via a digitizer to the archive and a workstation, there was no way to inform the radiologist that a study needed attention. In the case of outside films, the patient did not always have a medical record number that matched one in our Radiology Information Systems (RIS). In order to incorporate all studies for a patient, we needed common locations for orders, reports, and images. RIS orders

  10. How to optimize radiological images captured from digital cameras, using the Adobe Photoshop 6.0 program.

    Science.gov (United States)

    Chalazonitis, A N; Koumarianos, D; Tzovara, J; Chronopoulos, P

    2003-06-01

    Over the past decade, the technology that permits images to be digitized and the reduction in the cost of digital equipment allows quick digital transfer of any conventional radiological film. Images then can be transferred to a personal computer, and several software programs are available that can manipulate their digital appearance. In this article, the fundamentals of digital imaging are discussed, as well as the wide variety of optional adjustments that the Adobe Photoshop 6.0 (Adobe Systems, San Jose, CA) program can offer to present radiological images with satisfactory digital imaging quality.

  11. Aerial radiological measuring system program

    International Nuclear Information System (INIS)

    Doyle, J.F.; Boyns, P.K.

    1972-01-01

    The present ARMS aircraft has an effective survey time of four hours. Typical survey altitudes are 300 to 500 feet for terrain surveys and up to 20,000 feet for cloud tracks. A number of special airframe modifications have been made to accommodate the various sensor systems. The ARMS radiation measurement system consists of fourteen 4-inch diameter by 4-inch thick sodium iodide (NaI) detectors, a summing network for the detector signals, single and multichannel analyzers, analog computers, digital display and recording equipment, a doppler radar position computer, and strip chart recorders. Major subsystems include meteorology sensors, multispectral camera systems, and an infrared scanner for thermal mapping. Additional radiation detectors include an alpha spectrometer and a beta counter, used to count filter samples taken from a 150 cfm air sampler, which is a permanent part of the aircraft. A small lead shield houses a 1 / 2 -in. x 3-in. NaI crystal for beta and gamma counting of air filter samples. Several BF 3 neutron detectors are also available for neutron counting. The raw data from the gross gamma count and the gamma spectral measurements are permanently recorded on paper tape, and they must undergo reduction and analysis for final characterization of the radiological properties of the surveyed area. (U.S.)

  12. Digital imaging in diagnostic radiology. Image quality - radiation exposure

    International Nuclear Information System (INIS)

    Schmidt, T.; Stieve, F.E.

    1996-01-01

    The publication contains the 37 lectures of the symposium on digital imaging in diagnostic radiology, held in November 1995 at Kloster Seeon, as well as contributions enhancing the information presented in the lectures. The publication reflects the state of the art in this subject field, discusses future trends and gives recommendations and information relating to current practice in radiology. In-depth information is given about R and D activities for the digitalisation of X-ray pictures and the image quality required to meet the purposes of modern diagnostics. Further aspects encompass radiological protection and dose optimization as well as optimization of examination methods. (vhe) [de

  13. Quality control of the interpretation monitors of digital radiological images

    International Nuclear Information System (INIS)

    Favero, Mariana S.; Goulart, Adriano Oliveira S.

    2016-01-01

    The performance monitors has great importance in image quality of digital radiographic systems. In environments without films, it became necessary to implement acceptance testing and quality control monitors used for interpretation of medical images. The monitors dedicated to radiodiagnostic should provide information that represent slight differences in x-ray attenuation or minor differences in some anatomical region of interest. This should also result in small differences in luminance of an image represented. Factors affecting the quality of medical imaging are contrast, noise, resolution, artifacts and distortions. Therefore, a monitor must have specific characteristics, making it possible for the observer to carry out an assessment that leads to better diagnosis. Based on the need to evaluate diagnostic monitors in various radiological applications, this paper presents a summary for implementation and standardization of tests that are recommended by the publication AAPM Report 03. (author)

  14. Pediatric digital radiography education for radiologic technologists: current state

    International Nuclear Information System (INIS)

    Morrison, Gregory; Culbertson, John; Carbonneau, Kira; John, Susan D.; Goske, Marilyn J.; Smith, Susan N.; Charkot, Ellen; Herrmann, Tracy

    2011-01-01

    Digital radiography (DR) is one of several new products that have changed our work processes from hard copy to digital formats. The transition from analog screen-film radiography to DR requires thorough user education because of differences in image production, processing, storage and evaluation between the forms of radiography. Without adequate education, radiologic technologists could unknowingly expose children to higher radiation doses than necessary for adequate radiograph quality. To evaluate knowledge about image quality and dose management in pediatric DR among radiologic technologists in the U.S. This communication describes a survey of 493 radiologic technologists who are members of the American Society of Radiologic Technologists (ASRT) and who evaluated the current state of radiological technologist education in image quality and dose management in pediatric DR. The survey included 23 survey questions regarding image acquisition issues, quality assurance, radiation exposure and education in DR of infants and children. Radiologic technologists express many needs in areas of training and education in pediatric DR. Suggested improvements include better tools for immediate feedback about image quality and exposure, more information about appropriate technique settings for pediatric patients, more user-friendly vendor manuals and educational materials, more reliable measures of radiation exposure to patients, and more regular and frequent follow-up by equipment vendors. There is a clear and widespread need for comprehensive and practical education in digital image technology for radiologic technologists, especially those engaged in pediatric radiography. The creation of better educational materials and training programs, and the continuation of educational opportunities will require a broad commitment from equipment manufacturers and vendors, educational institutions, pediatric radiology specialty organizations, and individual imaging specialists. (orig.)

  15. Evaluation of the detector response function digital conventional radiology

    International Nuclear Information System (INIS)

    Arino Gil, A.; Hernandez Rodriguez, J.; Mateos Salvador, P.; Rodriguez Lopez, B.; Font Gelabert, J. C.

    2013-01-01

    The objective of this work is to obtain the response function that relates the air kerma at the entrance of the detector and pixel value, for a series of digital detectors of conventional Radiology model Optimus DigitalDiagnost Philips () and 6000 Definium General Electric. From the set of measurements is obtained a response function for each reference type of detector, and compared with those published in the literature for these teams. (Author)

  16. Poor collimation in digital radiology: A growing concern

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    Recommendations for radiation protection origin from the fact that the x-rays can produce genetic and somatic mutations9, especially in pediatric radiology due to their high radiation sensitivity and susceptibility to radiation-induced cancers such as childhood leukemia5,10. Digital radiography was introduced in the 1980s11 ...

  17. Factors to consider in the transition to digital radiological imaging.

    LENUS (Irish Health Repository)

    MacDonald, David

    2009-02-01

    The dentist considering adopting digital radiological technology should consider more than the type of detector with which to capture the image. He\\/she should also consider the mode of display, image enhancement, radiation dose reduction, how the image can be stored long term, and infection control.

  18. ICRP recommendations on 'managing patient dose in digital radiology'

    International Nuclear Information System (INIS)

    Vano, E.

    2005-01-01

    The International Commission on Radiological Protection (ICRP) approved the publication of a document on 'Managing patient dose in digital radiology' in 2003. The paper describes the content of the report and some of its key points, together with the formal recommendations of the Commission on this topic. With digital techniques exists not only the potential to improve the practice of radiology but also the risk to overuse radiation. The main advantages of digital imaging: wide dynamic range, post-processing, multiple viewing options, electronic transfer and archiving possibilities are clear but overexposures can occur without an adverse impact on image quality. It is expected that the ICRP report helps to profit from the benefits of this important technological advance in medical imaging with the best management of radiation doses to the patients. It is also expected to promote training actions before the digital techniques are introduced in the radiology departments and to foster the industry to offer enough technical and dosimetric information to radiologists, radiographers and medical physicists to help in the optimisation of the imaging. (authors)

  19. Workflow improvement and efficiency gain with near digitalization of a Radiology Department

    International Nuclear Information System (INIS)

    Langen, H.L.; Bielmeier, J.; Selbach, R.; Wittenberg, G.; Feustel, H.

    2003-01-01

    Purpose: To determine the temporal changes of the workflow caused by digitalization of the radiology department after installation of digital luminescence-radiography (DLR), a radiology information system (RIS) and picture archiving and communication system (PACS) at the Missionsaerztliche Klinik in April 2000. Materials and methods: In a comparative study, a workflow analysis by manual registration of different work steps was performed before (1999) and after (2001) digitalization of a radiology department. Results: The digitalization shortened the examination time for patients from a mean of 8 min to 5 min. The time the patient is absent from the emergency room did not change. Reporting radiographic examinations including comparison with previous studies begins earlier from a mean of 2 h 37 min to 17 min. Using PACS, 85.9% of all cases could be interpreted on the day of the examination (without PACS 41.2%) and 87.2% of the reports were completed the day after the examination (without PACS 64.5%). No time differences were found between reading conventional studies on the monitor or as soft-copy. Conclusion: Compared to conventional film-screen systems, complete digitalization of a radiology department is time saving at nearly all steps of the workflow, with expected positive effects on the workflow quality of the entire hospital. (orig.) [de

  20. [Workflow improvement and efficiency gain with near total digitalization of a radiology department].

    Science.gov (United States)

    Langen, H-L; Bielmeier, J; Wittenberg, G; Selbach, R; Feustel, H

    2003-10-01

    To determine the temporal changes of the workflow caused by digitalization of the radiology department after installation of digital luminescence-radiography (DLR), a radiology information system (RIS) and picture archiving and communication system (PACS) at the Missionsärztliche Klinik in April 2000. In a comparative study, a workflow analysis by manual registration of different work steps was performed before (1999) and after (2001) digitalization of a radiology department. The digitalization shortened the examination time for patients from a mean of 8 min to 5 min. The time the patient is absent from the emergency room did not change. Reporting radiographic examinations including comparison with previous studies begins earlier from a mean of 2 h 37 min to 17 min. Using PACS, 85.9 % of all cases could be interpreted on the day of the examination (without PACS 41.2 %) and 87.2 % of the reports were completed the day after the examination (without PACS 64.5 %). No time differences were found between reading conventional studies on the monitor or as soft-copy. Compared to conventional film-screen systems, complete digitalization of a radiology department is time saving at nearly all steps of the workflow, with expected positive effects on the workflow quality of the entire hospital.

  1. Radiology information management system, TOSRIM

    International Nuclear Information System (INIS)

    Tani, Yuichiro; Uchiyama, Akira; Kimura, Hirohito

    1991-01-01

    This is a report on a new type of distributed computer system for radiology departments named 'TOSRIM' (Toshiba radiology information management system), which is designed to be installed between medical diagnosis equipment and a host computer system in a hospital. Recently, a new type of host computer system has been developed which enables doctors to order any of the hospital's entire activities using terminals. By connecting 'TOSRIM' to this type of host computer system, many of the activities of a radiology department can be carried out via terminals without the use of examination requirement forms. As well as being connected to medical diagnosis equipment, 'TOSRIM' can also be connected to a medical imaging system which stores and displays medical images. By means of these connections, doctors will be able to diagnose medical images using display terminals without the need for films. (author)

  2. Radiology information management system, TOSRIM

    Energy Technology Data Exchange (ETDEWEB)

    Tani, Yuichiro; Uchiyama, Akira; Kimura, Hirohito (Toshiba Corp., Kawasaki, Kanagawa (Japan))

    1991-02-01

    This is a report on a new type of distributed computer system for radiology departments named 'TOSRIM' (Toshiba radiology information management system), which is designed to be installed between medical diagnosis equipment and a host computer system in a hospital. Recently, a new type of host computer system has been developed which enables doctors to order any of the hospital's entire activities using terminals. By connecting 'TOSRIM' to this type of host computer system, many of the activities of a radiology department can be carried out via terminals without the use of examination requirement forms. As well as being connected to medical diagnosis equipment, 'TOSRIM' can also be connected to a medical imaging system which stores and displays medical images. By means of these connections, doctors will be able to diagnose medical images using display terminals without the need for films. (author).

  3. Adequacy of source to image receptor distance with chest postero-anterior projection in digital radiology system

    Energy Technology Data Exchange (ETDEWEB)

    Joo, Young Cheol [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Lim, Cheong Hwan; Jung, Hong Ryang [Dept. of Radiology, Science, Hanseo University, Seosan (Korea, Republic of); You, In Gyu [Dept. of Radiology, Hallym University Hospital, Chuncheon (Korea, Republic of); Lee, Sang Ho [Dept. of Radiology, Science, Seonam University, Namwon (Korea, Republic of)

    2016-06-15

    The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7⁓3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6⁓2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6⁓8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6⁓8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment.

  4. Adequacy of source to image receptor distance with chest postero-anterior projection in digital radiology system

    International Nuclear Information System (INIS)

    Joo, Young Cheol; Lim, Cheong Hwan; Jung, Hong Ryang; You, In Gyu; Lee, Sang Ho

    2016-01-01

    The purpose of this study is to evaluate propriety of using SID 180cm at Chest PA examination and to find effect of geometrical cause to the image. XGEO-GC80, INNOVISION-SH, CXDI-40EG detector and a chest phantom designed self-production was used for this study. Images were acquired at SID 180cm with changing the factor OID as 0, 75 and 83mm and were analyzed by Centricity Radiography RA1000 PACS system. Statistical program was used the SPSS (Version 22.0, SPSS, Chicago, IL, USA), p-value(under 0.05) was considered to be statistically significant. In OID 0 mm was enlarged about 2.7⁓3.5 mm than the actual degree of the HS, BS of phantom in all equipments. Compared with the calculated magnification has been expanded 1.6⁓2.8% when viewed. The OID 75 mm with OID 83 mm was extended from the CS and BS 6⁓8 mm range. Compared to the calculated values, the measured values are expanded from 6.1 to 7.9%. CS and BS according to the OID change showed a statistically significant difference (p<0.05) among each group, the post-analysis only OID 0 mm group appeared as an independent group, 75 mm and 83 mm are separated in the same group It was. But had no statistically significant difference could change depending on the OID (p>0.05), post-mortem analysis showed, both in the same group. Heart sizes appears larger than actual size 6⁓8 mm at chest PA examination which is enlarged 6.1~7.9% more than the actual theoretical value. We can find magnification of the image because of the increase of the OID due to technical limitations between cover of standing detector and the image plate. so we suggest to have occurred between them when considering the need to adjust the equipment installed by the SID to match the characteristics of the equipment

  5. How Secure Is Your Radiology Department? Mapping Digital Radiology Adoption and Security Worldwide.

    Science.gov (United States)

    Stites, Mark; Pianykh, Oleg S

    2016-04-01

    Despite the long history of digital radiology, one of its most critical aspects--information security--still remains extremely underdeveloped and poorly standardized. To study the current state of radiology security, we explored the worldwide security of medical image archives. Using the DICOM data-transmitting standard, we implemented a highly parallel application to scan the entire World Wide Web of networked computers and devices, locating open and unprotected radiology servers. We used only legal and radiology-compliant tools. Our security-probing application initiated a standard DICOM handshake to remote computer or device addresses, and then assessed their security posture on the basis of handshake replies. The scan discovered a total of 2774 unprotected radiology or DICOM servers worldwide. Of those, 719 were fully open to patient data communications. Geolocation was used to analyze and rank our findings according to country utilization. As a result, we built maps and world ranking of clinical security, suggesting that even the most radiology-advanced countries have hospitals with serious security gaps. Despite more than two decades of active development and implementation, our radiology data still remains insecure. The results provided should be applied to raise awareness and begin an earnest dialogue toward elimination of the problem. The application we designed and the novel scanning approach we developed can be used to identify security breaches and to eliminate them before they are compromised.

  6. Osteoporosis: a new approach of digital processing of radiological images

    International Nuclear Information System (INIS)

    Salles, Adilson Dias; Braz, Valeria Silva

    1998-01-01

    The authors applied a method based on digital processing of radiological images (fast Fourier transform) to analyze the radius distal epiphysis and calcaneus spongy bone architecture. The study revealed distinct patterns of trabecular distribution. Prior studies about osteoporosis have focused on bone density quantification and its role on fracture prediction. However, resistance to fractures (mechanical strength) is also determined by structural arrangement of bone. THe digital processing (spectral analysis) was applied to radiological images of the radius and calcaneus from 15 normal and osteopenic individuals. Normal bone trabeculae showed an individualized behavior (stress lines). On the other hand, porotic bone trabeculae revealed a diffuse pattern (honey comb). The scattered frequency components showed that the porotic bone trabeculae were remodeled. This process would be responsible for the maintenance of its physical properties. (author)

  7. Application of geographic information system for radiologic emergency response

    International Nuclear Information System (INIS)

    Best, R.G.; Doyle, J.F.; Mueller, P.G.

    1998-01-01

    Comprehensive and timely radiological, cultural, and environmental data are required in order to make informed decisions during a radiological emergency. Within the Federal Radiological Monitoring and Assessment Center (FRMAC), there is a continuing effort to improve the data management and communication process. The most recent addition to this essential function has been the development of the Field Analysis System for Emergency Response (FASER). It is an integrated system with compatible digital image processing and Geographic Information System (GIS) capabilities. FASER is configured with commercially available off-the-shelf hardware and software components. To demonstrate the potential of the FASER system for radiological emergency response, the system has been utilized in interagency FRMAC exercises to analyze the available spatial data to help determine the impact of a hypothetical radiological release and to develop mitigation plans. (R.P.)

  8. Converting Radiology Operations in a Six-Hospital Healthcare System from Film-Based to Digital: Another Leadership Role for the Diagnostic Medical Physicist

    International Nuclear Information System (INIS)

    Arreola, Manuel M.; Rill, Lynn N.

    2004-01-01

    As medical facilities across the United States continue to convert their radiology operations from film-based to digital environments, partially accomplished and failed endeavors are frequent because of the lack of competent and knowledgeable leadership. The diagnostic medical physicist is, without a doubt, in a privileged position to take such a leadership role, not only because of her/his understanding of the basics principles of new imaging modalities, but also because of her/his inherent participation in workflow design and educational/training activities. A well-structured approach by the physicist will certainly lead the project to a successful completion, opening, in turn, new opportunities for the medical physicist to become an active participant in the decision-making process for an institution

  9. Converting Radiology Operations in a Six-Hospital Healthcare System from Film-Based to Digital: Another Leadership Role for the Diagnostic Medical Physicist

    Science.gov (United States)

    Arreola, Manuel M.; Rill, Lynn N.

    2004-09-01

    As medical facilities across the United States continue to convert their radiology operations from film-based to digital environments, partially accomplished and failed endeavors are frequent because of the lack of competent and knowledgeable leadership. The diagnostic medical physicist is, without a doubt, in a privileged position to take such a leadership role, not only because of her/his understanding of the basics principles of new imaging modalities, but also because of her/his inherent participation in workflow design and educational/training activities. A well-structured approach by the physicist will certainly lead the project to a successful completion, opening, in turn, new opportunities for the medical physicist to become an active participant in the decision-making process for an institution.

  10. Urogenital system diseases's radiological evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Bianchi, S; Mecozzi, B

    1985-01-01

    Radiological urogenital radiography reliability, can be compromised because of absence of a correct urodynamic diagnosis. It is then required that specialist radiologists know the problems concerning the urogenital system radiographies cannot be made in many cases, because of the scarcity in hospitals of idoneous urodynamic services.

  11. A comprehensive radiology information system

    International Nuclear Information System (INIS)

    Jost, R.G.

    1985-01-01

    DECrad version II was recently tested by members of the Radiology Information System Consortium (RISC) and was found to meet the specifications prepared by the consortium. It is a comprehensive tailorable system that can be interfaced to practically any HIS. This paper provides an overall view of the major functions of the system which include registration, scheduling, tracking, film library management, reporting, statistics, and teaching modules. The evolution of the specification and user experiences is reported

  12. Acceptable levels of digital image compression in chest radiology

    International Nuclear Information System (INIS)

    Smith, I.

    2000-01-01

    The introduction of picture archival and communications systems (PACS) and teleradiology has prompted an examination of techniques that optimize the storage capacity and speed of digital storage and distribution networks. The general acceptance of the move to replace conventional screen-film capture with computed radiography (CR) is an indication that clinicians within the radiology community are willing to accept images that have been 'compressed'. The question to be answered, therefore, is what level of compression is acceptable. The purpose of the present study is to provide an assessment of the ability of a group of imaging professionals to determine whether an image has been compressed. To undertake this study a single mobile chest image, selected for the presence of some subtle pathology in the form of a number of septal lines in both costphrenic angles, was compressed to levels of 10:1, 20:1 and 30:1. These images were randomly ordered and shown to the observers for interpretation. Analysis of the responses indicates that in general it was not possible to distinguish the original image from its compressed counterparts. Furthermore, a preference appeared to be shown for images that have undergone low levels of compression. This preference can most likely be attributed to the 'de-noising' effect of the compression algorithm at low levels. Copyright (1999) Blackwell Science Pty. Ltd

  13. Cost analysis of operating an all-digital radiology department

    International Nuclear Information System (INIS)

    Arenson, R.L.; Soshadri, S.B.; DeSimone, D.; Hiss, S.S.

    1988-01-01

    Using the current film system as a baseline, this study analyzes the cost of digital acquisition, transmission, archiving, and display of all images generated in our department. Two approaches are considered: (1) conventional x-ray films are digitized with a laser scanning film digitizer; (2) images are captured with a direct digital receptor and no film is created. In both approaches, images from digital modalities are acquired directly from the scanners. The cost of equipment and its maintenance, film, supplies, storage space, operations, personnel, and so forth are analyzed for all approaches. The annual cost of operating the film system is $2.5 million. The estimated annual cost is $2.3 million for the first digital approach, $1.8 million for the second. This analysis demonstrates that these digital approaches can be cost-effective, viable alternatives to film-bases systems

  14. Quality assurance in digital dental radiography--justification and dose reduction in dental and maxillofacial radiology.

    Science.gov (United States)

    Hellstern, F; Geibel, M-A

    2012-01-01

    To evaluate the implementation of quality assurance requirements for digital dental radiography in routine clinical practice. The results should be discussed by radiation protection authorities in the context of the relevant legal requirements and current debates on radiation protection. Two hundred digital dental radiographs were randomly selected from the digital database of the Department of Dentistry's Dental and Maxillofacial Surgery Clinic, Ulm University, and evaluated for various aspects of image quality and compliance with radiographic documentation requirements. The dental films were prepared by different radiology assistants (RAs) using one of two digital intraoral radiographic systems: Sirona Heliodent DS, 60 kV, focal spot size: 0.7 mm (group A) or KaVo Gendex 765 DC, 65 kV, focal spot size: 0.4 mm (group B). Radiographic justification was documented in 70.5% of cases, and the radiographic findings in 76.5%. Both variables were documented in the patient records as well as in the software in 14% of cases. Clinical documentation of the required information (name of the responsible dentist and radiology assistant, date, patient name, department, tube voltage, tube current, exposure time, type of radiograph, film size, department and serial number of the dental radiograph) was 100% complete in all cases. Moreover, the department certified according to DIN ISO 9001:2008 specifications demonstrated complete clinical documentation of radiographic justifications and radiographic findings. The entire dentition was visible on 83% of the digital films. The visible area corresponded to the target region on 85.7% of the digital dental radiographs. Seven to 8.5% of the images were classified as "hypometric" or "hypermetric". This study indicates that improvements in radiology training and continuing education fordentists and dental staff performing x-ray examinations are needed to ensure consistent high quality of digital dental radiography. Implementation of

  15. Comparative evaluation of image quality of various digital radiology systems and quality control and optimization of radiation protection at the Amiens university hospital

    International Nuclear Information System (INIS)

    Foro, Saturnin Didace L.

    2004-01-01

    This study was centered on two axes: the first is the comparative evaluation of image quality of various numerical radiology system, the second is the quality control and the optimization of protection against radiation. The publication of directive 97/43 Euratom from council of June 30, 1997 and consequently, the decree of February 12, 2004 founded a strict lawful framework that is engaged to respect the University Hospital of Amiens by the installation of a operational dosimetry system and the application of February 12, 2004 decree. (author) [fr

  16. Use of OsiriX in developing a digital radiology teaching library

    International Nuclear Information System (INIS)

    Shamshuddin, S.; Matthews, H.R.

    2014-01-01

    Widespread adoption of digital imaging in clinical practice and for the image-based examinations of the Royal College of Radiologists has created a desire to provide a digital radiology teaching library in many hospital departments around the UK. This article describes our experience of using OsiriX software in developing digital radiology teaching libraries

  17. Digital processing methodology applied to exploring of radiological images

    International Nuclear Information System (INIS)

    Oliveira, Cristiane de Queiroz

    2004-01-01

    In this work, digital image processing is applied as a automatic computational method, aimed for exploring of radiological images. It was developed an automatic routine, from the segmentation and post-processing techniques to the radiology images acquired from an arrangement, consisting of a X-ray tube, target and filter of molybdenum, of 0.4 mm and 0.03 mm, respectively, and CCD detector. The efficiency of the methodology developed is showed in this work, through a case study, where internal injuries in mangoes are automatically detected and monitored. This methodology is a possible tool to be introduced in the post-harvest process in packing houses. A dichotomic test was applied to evaluate a efficiency of the method. The results show a success of 87.7% to correct diagnosis and 12.3% to failures to correct diagnosis with a sensibility of 93% and specificity of 80%. (author)

  18. Digital subtraction angiography in head and neck radiology

    International Nuclear Information System (INIS)

    Carmody, R.F.; Seeger, J.F.; Smith, R.L.; Horsley, W.W.; Miller, R.W.

    1984-01-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally. (orig.)

  19. Digital subtraction angiography in head and neck radiology

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, R F; Seeger, J F; Smith, R L; Horsley, W W; Miller, R W

    1984-07-01

    Intravenous digital subtraction angiography (IVDSA) was used to evaluate 44 patients with suspected otolaryngologic abnormalities. Sixteen had IVDSA for pulsatile tinnitus or suspected glomus tumor of the petrous bone. Nine patients were evaluated because of pulsatile neck masses, and 12 others had suspected tumors of the neck, face, and paranasal sinuses. Seven had IVDSA following head and neck trauma. The technique of examination is described. The current indications of IVDSA in head and neck radiology are discussed. It is concluded that IVDSA is a suitable substitute for conventional angiography for many otolaryngologic conditions and, because of its safety, can be used more liberally.

  20. The advantages of digital radiography in department of radiology

    International Nuclear Information System (INIS)

    Mao Lijuan; Luo Xiaomei; Wu Tengfang

    2009-01-01

    Objective: To investigate the advantages of digital radiography in department of radiology by comparing digital radiography with common radiography. Methods: Test card was used for testing the spatial resolution of DR and common radiography. 1000 films of chest by DR and 1000 films of chest by common radiography were compared in image quality, dose of radiation, the rate of waste film, and the advantages of DR was analyzed. Results: Compared to common radiography, DR had a high sensitivity, high DQE (quantum detection efficiency), high spatial resolution and density resolution. The speed of acquisition and X-ray conversion efficiency were fast. The function of post-processing was strong and the rate of disease detection was high. Conclusion: DR is better than common radiography in all respects, it will be widely applied. (authors)

  1. Relevant training issues for introduction of digital radiology: Results of a survey

    International Nuclear Information System (INIS)

    Peer, S.; Faulkner, K.; Torbica, P.; Peer, R.; Busch, H. P.; Vetter, S.; Neofotistou, E.; Back, C.; Bosmans, H.; Vano, E.

    2005-01-01

    Council Directive 97/43/Euratom establishes the need for adequate training of radiology staff. The transition to digital radiology implies changes in various imaging aspects, which are not sufficiently covered by current institutional training programmes. This work aimed to assess how professionals, experienced in digital imaging, acquired their expertise and hence, what form institutional training should take. Within DIMOND III, a survey on training and resources was performed among radiology professionals. A lack of institutional education for digital radiology was found. In the transition to digital radiology, 30-35% train on the job and another 23-28% receive training from digital equipment vendors. A general agreement exists on the need for new quality criteria and strategies for dose management. Issues relevant for conventional/digital transition are only sparsely covered in EC training programmes. Based on these results, a set of training issues was produced, to be included in future European guidelines. (authors)

  2. Test objects for evaluating the performance of radiological imaging systems. Leeds radiological test objects

    International Nuclear Information System (INIS)

    Cowen, A.R.; Clarke, O.F.; Haywood, J.M.; Parker, R.P.

    1985-01-01

    A range of test objects has been developed to assess the imaging performance of conventional and digital radiological imaging systems. These test objects have arisen as a result of involvement in both the laboratory evaluation of radiological imaging systems and the routine maintenance of such equipment in a large diagnostic radiology department. The philosophy behind the design and application of the test objects is briefly described. Particular attention is paid to the advantages of using the threshold-contrast detail-detectability technique to assess overall imaging performance. The great importance of ensuring optimum imaging performance prior to clinical acceptance is stressed. A strategy for implementing the test objects in a clinical department is present. The diagnostic information content of the clinical images which result measures the success of the quality control procedure adopted. (author)

  3. Quality management systems in radiology

    Directory of Open Access Journals (Sweden)

    Geoffrey K. Korir

    2013-08-01

    Objective: To assess the level of quality management systems in X-ray medical facilities in Kenya. Methods: Quality management inspection, quality control performance tests and patient radiation exposure were assessed in 54 representative X-ray medical facilities. Additionally, a survey of X-ray examination frequency was conducted in 140 hospitals across the country. Results: The overall findings placed the country’s X-ray imaging quality management systems at 61±3% out of a possible 100%. The most and the least quality assurance performance indicators were general radiography X-ray equipment quality control tests at 88±4%, and the interventional cardiology adult examinations below diagnostic reference level at 25±1%, respectively. Conclusions: The study used a systematic evidence-based approach for the assessment of national quality management systems in radiological practice in clinical application, technical conduct of the procedure, image quality criteria, and patient characteristics as part of the quality management programme.

  4. Precision digital control systems

    Science.gov (United States)

    Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.

    This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.

  5. Radiological approach to systemic connective tissue diseases

    International Nuclear Information System (INIS)

    Wiesmann, W.; Schneider, M.

    1988-01-01

    Systemic lupus erythematosus (SLE) and progressive systemic sclerosis (PSS) represent the most frequent manifestations of systemic connective tissue diseases (collagen diseases). Radiological examinations are employed to estimate the extension and degree of the pathological process. In addition, progression of the disease can be verified. In both of the above collagen diseases, specific radiological findings can be observed that permit them to be differentiated from other entities. An algorithm for the adequate radiological work-up of collagen diseases is presented. (orig.) [de

  6. Radiological approach to systemic connective tissue diseases

    Energy Technology Data Exchange (ETDEWEB)

    Wiesmann, W; Schneider, M

    1988-07-01

    Systemic lupus erythematosus (SLE) and progressive systemic sclerosis (PSS) represent the most frequent manifestations of systemic connective tissue diseases (collagen diseases). Radiological examinations are employed to estimate the extension and degree of the pathological process. In addition, progression of the disease can be verified. In both of the above collagen diseases, specific radiological findings can be observed that permit them to be differentiated from other entities. An algorithm for the adequate radiological work-up of collagen diseases is presented.

  7. Advanced image display systems in radiology

    International Nuclear Information System (INIS)

    Wendler, T.

    1987-01-01

    Advanced image display systems for the fully digital diagnostic imaging departments of the future will be far more than simple replacements of the traditional film-viewing equipment. The new capabilities of very high resolution and highly dynamic displays offer a userfriendly and problem-oriented way of image interpretation. Advanced harware-, software- and human-machine interaction-concepts have been outlined. A scenario for a future way of handling and displaying images, reflecting a new image viewing paradigm in radiology is sketched which has been realized in an experimental image workstation model in the laboratory which, despite its technical complexity, offers a consistent strategy for fast and convenient interaction with image objects. The perspective of knowledge based techniques for workstation control software with object-oriented programming environments and user- and task-adaptive behavior leads to more advanced display properties and a new quality of userfriendliness. 2 refs.; 5 figs

  8. A radiographic image archive system on digital optical disks

    International Nuclear Information System (INIS)

    Mankovich, N.J.; Taira, R.K.; Cho, P.S.; Wong, W.K.; Stewart, B.K.; Huang, H.K.

    1986-01-01

    The recent introduction of projection computed radiography (CR) systems allows radiology departments to consider digital operation in over 90% of performed procedures. Ideally, current patient procedures from CT, CT, and MR along with laser-digitized historical films should be centrally stored at their full digital resolution. Magnetic disks, because of their limited storage capacity and expense, can only retain these data on a limited basis. The author devised an optical disk archive system which automatically stores images directly onto 2.6-gigabyte optical cartridges without recourse to film. This system is in full clinical operation in the UCLA Pediatric Radiology Section of the authors' department. From this experience they present (a) an analysis of the digital archiving requirements of the Pediatric Radiology Section based on CR, CT, MR, and laser digitized films; (b) the archive and retrieval methods along with performance statistics; and (c) the procedure for assuring digital image integrity

  9. [Digitalization of radiological imaging information and consequences for patient care in the hospital ].

    Science.gov (United States)

    den Heeten, G J; Barneveld Binkhuysen, F H

    2001-08-25

    Determining the rate at which radiology must be digitalised has been a controversial issue for many years. Much radiological information is still obtained from the film-screen combination (X-rays) with all of its known inherent restrictions. The importance of imaging information in the healthcare process continues to increase for both radiologists and referring physicians, and the ongoing developments in information technology means that it is possible to integrate imaging information and electronic patient files. The healthcare process can only become more effective and efficient when the appropriate information is in the right place at the right time, something that conventional methods, using photos that need to be physically moved, can scarcely satisfy. There is also a desire for integration with information obtained from nuclear medicine, pathology and endoscopy, and eventually of all stand-alone data systems with relevance for the individually oriented hospital healthcare. The transition from a conventional to a digital process is complex; it is accompanied by the transition from a data-oriented to a process-oriented system. Many years have already been invested in the integration of information systems and the development of digital systems within radiology, the current performance of which is such that many hospitals are considering the digitalisation process or are already implementing parts of it.

  10. Use of OsiriX in developing a digital radiology teaching library.

    Science.gov (United States)

    Shamshuddin, S; Matthews, H R

    2014-10-01

    Widespread adoption of digital imaging in clinical practice and for the image-based examinations of the Royal College of Radiologists has created a desire to provide a digital radiology teaching library in many hospital departments around the UK. This article describes our experience of using OsiriX software in developing digital radiology teaching libraries. Copyright © 2014 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Digitalization in radiology--6 years in the St. Elisabeth Oncology Institute.

    Science.gov (United States)

    Valkovic, L; Lehotska, V; Magula, J; Tothova, L

    2008-01-01

    To determine advantages and specific problems of film-free digital hospital focused on radiology department. In the St. Elisabeth Oncology Institute in Bratislava we have more than 6-year experience with digital modalities and the PACS system. During this period many difficulties occurred and are expected to rise with an increasing number of digital modalities. Statistical evaluation of a 6-year period in numerous graphs and schemes. The amount of data can be seen in graphs, which show the amount of examinations and data volume from different modalities for specific time period to October 2007 and present volumes and increase of data amount in megabytes (MB) in the last 6 years. Despite of systematic capacity increase it is a long-term archiving and economical problem. It is crucial to solve the daily amount of data, backup copies, type of archiving media, and priority of data accessibility (Tab. 1, Fig. 5, Ref. 9). Full Text (Free, PDF) www.bmj.sk.

  12. Flat panel detectors - closing the (digital) gap in chest and skeletal radiology

    International Nuclear Information System (INIS)

    Reiff, Kurt J.

    1999-01-01

    In the radiological department today the majority of all X-ray procedures on chest and skeletal radiography is performed with classical film-screen-systems. Using digital luminescence radiography (DLR or CR, which stands for Computed Radiography) as a technique has shown a way to replace this 100-year-old procedure of doing general radiography work by acquiring the X-rays digitally via phosphor screens, but this approach has faced criticism from lots of radiologists world wide and therefore has not been widely accepted except in the intensive care environment. A new technology is now rising based on the use of so called flat panel X-ray (FD) detectors. Semi-conducting material detects the X-rays in digital form directly and creates an instantaneous image for display, distribution and diagnosis. This ability combined with a large field of view and -- compared to existing methods -- excellent detective quantum efficiency represents a revolutionary step for chest and skeletal radiography and will put basic X-ray-work back into the focus of radiological solutions. This paper will explain the basic technology of flat panel detectors, possible system solutions based on this new technology, aspects of the user interface influencing the system utilization and versatility as well as the possibility to redefine the patient examination process for chest and skeletal radiography. Furthermore the author discusses limitations for the first released systems, upgrades for the installed base and possible scenarios for the future. e.g. fluoroscopy or angiography application

  13. Managing patient dose in digital radiology; Gestión de la dosis al paciente en radiología digital

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2014-07-01

    Digital techniques have the potential to improve the practice of radiology but they also risk the overuse of radiation. The main advantages of digital imaging, i.e. wide dynamic range, post processing, multiple viewing options, and electronic transfer and archiving possibilities, are clear but overexposures can occur without an adverse impact on image quality. In conventional radiography, excessive exposure produces a black film. In digital systems, good images are obtained for a large range of doses. It is very easy to obtain (and delete) images with digital fluoroscopy systems, and there may be a tendency to obtain more images than necessary. In digital radiology, higher patient dose usually means improved image quality, so a tendency to use higher patient doses than necessary could occur. Different medical imaging tasks require different levels of image quality, and doses that have no additional benefit for the clinical purpose should be avoided. Image quality can be compromised by inappropriate levels of data compression and/or post processing techniques. All these new challenges should be part of the optimisation process and should be included in clinical and technical protocols. Local diagnostic reference levels should be re-evaluated for digital imaging, and patient dose parameters should be displayed at the operator console. Frequent patient dose audits should occur when digital techniques are introduced. Training in the management of image quality and patient dose in digital radiology is necessary. Digital radiology will involve new regulations and invoke new challenges for practitioners. As digital images are easier to obtain and transmit, the justification criteria should be reinforced. Commissioning of digital systems should involve clinical specialists, medical physicists, and radiographers to ensure that imaging capability and radiation dose management are integrated. Quality control requires new procedures and protocols (visualisation, transmission

  14. Digital mineral logging system

    International Nuclear Information System (INIS)

    West, J.B.

    1980-01-01

    A digital mineral logging system acquires data from a mineral logging tool passing through a borehole and transmits the data uphole to an electronic digital signal processor. A predetermined combination of sensors, including a deviometer, is located in a logging tool for the acquisition of the desired data as the logging tool is raised from the borehole. Sensor data in analog format is converted in the logging tool to a digital format and periodically batch transmitted to the surface at a predetermined sampling rate. An identification code is provided for each mineral logging tool, and the code is transmitted to the surface along with the sensor data. The self-identifying tool code is transmitted to the digital signal processor to identify the code against a stored list of the range of numbers assigned to that type of tool. The data is transmitted up the d-c power lines of the tool by a frequency shift key transmission technique. At the surface, a frequency shift key demodulation unit transmits the decoupled data to an asynchronous receiver interfaced to the electronic digital signal processor. During a recording phase, the signals from the logging tool are read by the electronic digital signal processor and stored for later processing. During a calculating phase, the stored data is processed by the digital signal processor and the results are outputted to a printer or plotter, or both

  15. Digital and analog communication systems

    Science.gov (United States)

    Shanmugam, K. S.

    1979-01-01

    The book presents an introductory treatment of digital and analog communication systems with emphasis on digital systems. Attention is given to the following topics: systems and signal analysis, random signal theory, information and channel capacity, baseband data transmission, analog signal transmission, noise in analog communication systems, digital carrier modulation schemes, error control coding, and the digital transmission of analog signals.

  16. Advantages of digital radiography: The DSI system

    International Nuclear Information System (INIS)

    Drouillard, J.

    1990-01-01

    The experience gained over a period of several months, applying the digital and image-enhanced radiography with the DSI system for examination of some hundreds of patients, has confirmed in our eyes the system's diagnostic and economic efficiency, and the important achievement of radiation dose abatement. Looking at the current results and improvements under way (Release 2), there is reason enough to support an extension of the range of indications, especially regarding arteriography and interventional radiography. According to our experience, the DSI system meets the requirements of a modern radiology department: reduction of operating costs, limitation of radiation dose, efficiency enhancement by digital imaging. (orig.) [de

  17. Experiences upgrading a fluoroscopic system to digital specifications

    International Nuclear Information System (INIS)

    Fox, T.; Fenzl, G.

    1995-01-01

    In 1993, an undertable fluoroscopic system was retrofitted with a Fluorospot HC digital system at the radiological clinic of the Knappschaftskrankenhaus in Puettlingen, Germany. The experiences and possibilities resulting from this digital upgrade are related by the authors, whose narrative is also accompanied by examples of clinical images. The costs involved are also discussed in this article. (orig.)

  18. Digital panoramic radiograph rejection index at a Dental Radiology Service in Paraná, Brazil

    International Nuclear Information System (INIS)

    Mickus, J.; Barros, F.S.; Sato, G.Y.; Rosa, P.C.

    2017-01-01

    Panoramic radiography is the most frequent extraoral examination in dentistry. This technique allows the visualization of adjacent maxillomandibular and anatomical structures. Although digital imaging systems are already the great majority of dental radiology services, there is still a shortage of works evaluating the quality of this type of image. The objective of this study was to identify the rejection index of digital panoramic radiographs of a dental radiology service of a university in Brazil, pointing out the main reasons. A survey was performed on the image files and, randomly selected, 2306 images, 10% of the examinations performed in the period between 2013 to 2015. The results indicated a total rejection rate of 5.1% over the three years, totaling 117 radiographs. The main reasons for rejection were: the patient's head tilted backwards in 2013 and the lack of tongue contact with the palate, for the years 2014 and 2015. The main reasons for repetition of exams are related to the positioning in the execution of the technique radiological factors, which may be related to the lack of professional training. Patient collaboration during the examination and professional-to-patient communication failures may result in poor diagnostic quality exams

  19. Standard guide for data fields for computerized transfer of digital radiological examination data

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2008-01-01

    1.1 This guide provides a listing and description of the fields that are recommended for inclusion in a digital radiological examination data base to facilitate the transfer of such data. This guide sets guidelines for the format of data fields for computerized transfer of digital image files obtained from radiographic, radioscopic, computed radiographic, or other radiological examination systems. The field listing includes those fields regarded as necessary for inclusion in the data base: (1) regardless of the radiological examination method (as indicated by Footnote C in Table 1), (2) for radioscopic examination (as indicated by Footnote E in Table 1), and (3) for radiographic examination (as indicated by Footnote D in Table 1). In addition, other optional fields are listed as a reminder of the types of information that may be useful for additional understanding of the data or applicable to a limited number of applications. 1.2 It is recognized that organizations may have in place an internal format for the...

  20. Digital knowledge in the coat pocket - hand-held personal digital assistants in radiology

    International Nuclear Information System (INIS)

    Niehues, S.M.; Froehlich, M.; Felix, R.; Lemke, A.J.

    2004-01-01

    The personal digital assistant (PDA) enables the independent access to large data in a pocket-sized format. The applications for hand-held computers are growing steadily and can support almost any kind of problem. An overview of the available hardware and software is provided and evaluated. Furthermore, the use of the PDA in the clinical daily routine is described. In view of the numerous software programs available in radiology, the range of software solutions for radiologists is presented. Despite the high acquisition cost, the PDA has already become the digital assistant for the radiologist. After a short time of getting used to the PDA, nobody wants to miss it at work or at home. New technical features and available software programs will continuously increase the integration of the PDA into the medical workflow in the near future. (orig.)

  1. Virtual radiology rounds: adding value in the digital era

    Energy Technology Data Exchange (ETDEWEB)

    Fefferman, Nancy R.; Strubel, Naomi A.; Prithiani, Chandan; Chakravarti, Sujata; Caprio, Martha; Recht, Michael P. [New York University School of Medicine, Department of Radiology, New York, NY (United States)

    2016-11-15

    To preserve radiology rounds in the changing health care environment, we have introduced virtual radiology rounds, an initiative enabling clinicians to remotely review imaging studies with the radiologist. We describe our initial experience with virtual radiology rounds and referring provider impressions. Virtual radiology rounds, a web-based conference, use remote sharing of radiology workstations. Participants discuss imaging studies by speakerphone. Virtual radiology rounds were piloted with the Neonatal Intensive Care Unit (NICU) and the Congenital Cardiovascular Care Unit (CCVCU). Providers completed a survey assessing the perceived impact and overall value of virtual radiology rounds on patient care using a 10-point scale. Pediatric radiologists participating in virtual radiology rounds completed a survey assessing technical, educational and clinical aspects of this methodology. Sixteen providers responded to the survey; 9 NICU and 7 CCVCU staff (physicians, nurse practitioners and fellows). Virtual radiology rounds occurred 4-5 sessions/week with an average of 6.4 studies. Clinicians rated confidence in their own image interpretation with a 7.4 average rating for NICU and 7.5 average rating for CCVCU. Clinicians unanimously rated virtual radiology rounds as adding value. NICU staff preferred virtual radiology rounds to traditional rounds and CCVCU staff supported their new participation in virtual radiology rounds. Four of the five pediatric radiologists participating in virtual radiology rounds responded to the survey reporting virtual radiology rounds to be easy to facilitate (average rating: 9.3), to moderately impact interpretation of imaging studies (average rating: 6), and to provide substantial educational value for radiologists (average rating: 8.3). All pediatric radiologists felt strongly that virtual radiology rounds enable increased integration of the radiologist into the clinical care team (average rating: 8.8). Virtual radiology rounds are a

  2. Virtual radiology rounds: adding value in the digital era

    International Nuclear Information System (INIS)

    Fefferman, Nancy R.; Strubel, Naomi A.; Prithiani, Chandan; Chakravarti, Sujata; Caprio, Martha; Recht, Michael P.

    2016-01-01

    To preserve radiology rounds in the changing health care environment, we have introduced virtual radiology rounds, an initiative enabling clinicians to remotely review imaging studies with the radiologist. We describe our initial experience with virtual radiology rounds and referring provider impressions. Virtual radiology rounds, a web-based conference, use remote sharing of radiology workstations. Participants discuss imaging studies by speakerphone. Virtual radiology rounds were piloted with the Neonatal Intensive Care Unit (NICU) and the Congenital Cardiovascular Care Unit (CCVCU). Providers completed a survey assessing the perceived impact and overall value of virtual radiology rounds on patient care using a 10-point scale. Pediatric radiologists participating in virtual radiology rounds completed a survey assessing technical, educational and clinical aspects of this methodology. Sixteen providers responded to the survey; 9 NICU and 7 CCVCU staff (physicians, nurse practitioners and fellows). Virtual radiology rounds occurred 4-5 sessions/week with an average of 6.4 studies. Clinicians rated confidence in their own image interpretation with a 7.4 average rating for NICU and 7.5 average rating for CCVCU. Clinicians unanimously rated virtual radiology rounds as adding value. NICU staff preferred virtual radiology rounds to traditional rounds and CCVCU staff supported their new participation in virtual radiology rounds. Four of the five pediatric radiologists participating in virtual radiology rounds responded to the survey reporting virtual radiology rounds to be easy to facilitate (average rating: 9.3), to moderately impact interpretation of imaging studies (average rating: 6), and to provide substantial educational value for radiologists (average rating: 8.3). All pediatric radiologists felt strongly that virtual radiology rounds enable increased integration of the radiologist into the clinical care team (average rating: 8.8). Virtual radiology rounds are a

  3. Future approaches to digital systems

    International Nuclear Information System (INIS)

    Woodrough, R.E.; Beckmann, E.; Jenkins, D.; Belcher, D.

    1984-01-01

    The introduction of the first digital imaging systems has led to the concept of a totally digital imaging department - the 'filmless department'. This concept and its associated network system for digital departments are briefly considered. A transducer system of scanned projection radiography with solid state detectors used in digital chest imaging is described. The principles of this transducer system are applicable to other forms of digital radiography. (U.K.)

  4. Estimation of dose challenge in radiological exams policontuses patients in public hospital in Santiago with digital radiology equipment

    International Nuclear Information System (INIS)

    Diaz-Munoz Ihmaidan, Gabriela

    2012-01-01

    lonizing radiation is always present in our natural environment and with the development of new technologies in diagnostic radiology we have elevated the exposure to radiation with an increased dose to both patient and professionals. This is of great importance for secondary stochastic effects that could be generated by exposure to ionizing radiation. There are different x-ray entrance dose studies in patients with radiological examinations in conventional radiology equipment, but not in trauma patients examinated with digital radiology equipment where there is a supposed greater exposure to radiation because of the increase of the number of radiological examinations requested. This study determined the doses received by trauma patients in a direct digital x ray equipment (in a ER in Santiago, Chile) and see if the doses are within the ones recommended by international societies. We used thermoluminescent crystals which were first properly calibrated and located in the center of the radiation beam. The results obtained show that using good practice we can obtain acceptable dose levels, independently of the digital equipment used where it is presumed that could give a higher dose of ionizing radiation exposure than conventional x-ray equipment

  5. Digital radiation monitor system

    International Nuclear Information System (INIS)

    Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan

    2003-01-01

    The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet

  6. Digital communication system

    International Nuclear Information System (INIS)

    Union, D.C.

    1980-01-01

    A digital communication system for communicating among two central consoles and a plurality of local controllers, e.g. in a radiation and monitoring system, provides communication between each of the consoles and all of the local controllers via dual paths. Each path is independent of the other and each extends from one of the consoles to all of the local controllers from opposite directions, thereby forming a unique non-continuous loop. (author)

  7. Radiological changes in systemic lupus erythematosis

    International Nuclear Information System (INIS)

    Fritsch, R.; Freyschmidt, J.; Suedhof-Mueller, G.; Menninger, H.; Medizinische Hochschule Hannover

    1981-01-01

    In a study of 50 patients with systemic lupus erythematosis, radiologically demonstrable lung changes and pleural effusions were found in 50%. Changes in the peripheral skeleton, such as osteoporosis, erosions or mutilations, were seen in only two patients. Our radiological analysis has shown that systemic lupus erythematosis does not produce changes in the joints, but is responsible for abnormalities in the lungs, as well as for pericardial and pleural effusions. (orig.) [de

  8. Radiological changes in systemic lupus erythematosis

    Energy Technology Data Exchange (ETDEWEB)

    Fritsch, R; Freyschmidt, J; Suedhof-Mueller, G; Menninger, H

    1981-05-01

    In a study of 50 patients with systemic lupus erythematosis, radiologically demonstrable lung changes and pleural effusions were found in 50%. Changes in the peripheral skeleton, such as osteoporosis, erosions or mutilations, were seen in only two patients. Our radiological analysis has shown that systemic lupus erythematosis does not produce changes in the joints, but is responsible for abnormalities in the lungs, as well as for pericardial and pleural effusions.

  9. Warning: digital systems ahead

    International Nuclear Information System (INIS)

    Albrigo, T.

    1994-01-01

    Digital systems will continue to enhance operation and safety in the nuclear industry. However, they are complex and operators have found it difficult to demonstrate the levels of reliability needed to justify their use. This article describes just some of the varied experiences collected by Arizona Public Service and lessons learned which show clearly why caution must be used whenever and wherever these are introduced. (author)

  10. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2005-11-01

    One of the main challenges facing radiological protection experts is how to integrate radiological protection within modern concepts of and approaches to risk governance. It is within this context that the International Commission on Radiological Protection (ICRP) decided to develop new general recommendations to replace its Publication 60 recommendations of 1990. In the process of developing these new recommendations, the views of the ICRP have evolved significantly, largely due to stakeholder involvement that has been actively solicited by the ICRP. In this regard, it was upheld during the First Asian Regional Conference organised by the NEA in October 2002 that the implementation of the new system must allow for regional, societal and cultural differences. In order to ensure appropriate consideration of these differences, the NEA organised the Second Asian Regional Conference on the Evolution of the System of Radiological Protection. Held in Tokyo on 28-29 July 2004, the conference included presentations by the ICRP Chair as well as by radiological experts from Australia, China, Japan and Korea. Within their specific cultural and socio-political milieu, Asia-Pacific and western ways of thought on how to improve the current system of radiological protection were presented and discussed. These ways of thinking, along with a summary of the conference results, are described in these proceedings. (author)

  11. Internet technology for clinical application in a digital radiology department

    International Nuclear Information System (INIS)

    Bergh, B.; Pietsch, M.; Vogl, T.J.

    2000-01-01

    Problem: To provide an overview and to assess the clinical feasibility of internet technology-based systems for hospital-wide image and report distribution as well as for video conferencing. Methods: The paper describes the theoretical concept behind, the various technical approaches and the experience gained from different systems. Results: Image and report distribution: Advantages include the universal availability of images and reports inside and outside hospitals; ease of use; security features; image and report integration; cost savings by reducing support and training efforts and by optimising available hardware. The main critical issues are performance and workflow integration with RIS and PACS. Video conferencing: Main advantages are the standardised, software-based approach and the low investments for hard- and software. Depending on the desired usage the communication performance can be seen as inappropriate. Conclusion: Today, internet technology-based systems appear to satisfy the main clinical needs in radiology. The mentioned drawbacks could be eliminated by means of modified software implementation and focused standardisation efforts. Considering the numerous advantages of these systems a further distribution can be expected for the future. (orig.) [de

  12. Preliminary investigation of the interaction between radiologists and digital radiologic work stations

    International Nuclear Information System (INIS)

    Fajardo, L.L.; McNeill, K.M.; Maloney, K.; Mockbee, B.

    1987-01-01

    Using a work station built in the authors' department, they conducted an investigation into the interaction between radiologist and a digital radiologic work station. A survey provided information regarding the experience of 18 radiologists with digital technology and their expectations of its benefits. They ranked the potential attributes of digital work stations, with spatial resolution first, followed by contrast resolution, ease of use, speed, ease of learning, and cost. Observation of the radiologists' interaction with the work station has provided recommendations for implementation of functions. The authors conclude that radiologic work station user interfaces must be intuitive and support the radiologist's task without increasing the time or effort required for the task

  13. Introduction to digital communication systems

    CERN Document Server

    Wesolowski, Krzysztof

    2009-01-01

    Combining theoretical knowledge and practical applications, this advanced-level textbook covers the most important aspects of contemporary digital communication systems. Introduction to Digital Communication Systems focuses on the rules of functioning digital communication system blocks, starting with the performance limits set by the information theory. Drawing on information relating to turbo codes and LDPC codes, the text presents the basic methods of error correction and detection, followed by baseband transmission methods, and single- and multi-carrier digital modulations. The basi

  14. The use of Leeds Test Objects in the assessment of the performance of radiological imaging systems: an introduction

    International Nuclear Information System (INIS)

    Cowen, A.R.

    1986-01-01

    Over the preceding decade the Leeds Radiological Imaging Group have developed a range of test objects with which to assess the performance of radiological imaging systems. The types of imaging equipment which can be assessed include X-ray image intensifier television systems, small-format 100mm/105mm fluorography systems and radiographic screen-film combinations. We have recently extended our interest to the evaluation of digital radiological imaging equipment including digital subtraction fluorography and digital (greyscale) radiographic imaging systems. These test objects were initially developed for the purpose of evaluating imaging performance under laboratory conditions but they have also proved useful under field (clinical) conditions. (author)

  15. Application of Oversampling to obtain the MTF of Digital Radiology Equipment.

    Science.gov (United States)

    Narváez, M.; Graffigna, J. P.; Gómez, M. E.; Romo, R.

    2016-04-01

    Within the objectives of theproject Medical Image Processing for QualityAssessment ofX Ray Imaging, the present research work is aimed at developinga phantomX ray image and itsassociated processing algorithms in order to evaluatethe image quality rendered by digital X ray equipment. These tools are used to measure various image parameters, among which spatial resolution shows afundamental property that can be characterized by the Modulation Transfer Function (MTF)of an imaging system [1]. After performing a thorough literature surveyon imaging quality control in digital X film in Argentine and international publications, it was decided to adopt for this work the Norm IEC 62220 1:2003 that recommends using an image edge as a testingmethod. In order to obtain the characterizing MTF, a protocol was designedfor unifying the conditions under which the images are acquired for later evaluation. The protocol implied acquiring a radiography image by means of a specific referential technique, i.e. referred either to voltage, current, time, distance focus plate (/film?) distance, or other referential parameter, and to interpret the image through a system of computed radiology or direct digital radiology. The contribution of the work stems from the fact that, even though the traditional way of evaluating an X film image quality has relied mostly on subjective methods, this work presents an objective evaluative toolfor the images obtained with a givenequipment, followed by a contrastive analysis with the renderings from other X filmimaging sets.Once the images were obtained, specific calculations were carried out. Though there exist some methods based on the subjective evaluation of the quality of image, this work offers an objective evaluation of the equipment under study. Finally, we present the results obtained on different equipment.

  16. Application of Oversampling to obtain the MTF of Digital Radiology Equipment

    International Nuclear Information System (INIS)

    Narváez, M.; Graffigna, J. P.; Gómez, M. E.; Romo, R.

    2016-01-01

    Within the objectives of theproject Medical Image Processing for QualityAssessment ofX Ray Imaging, the present research work is aimed at developinga phantomX ray image and itsassociated processing algorithms in order to evaluatethe image quality rendered by digital X ray equipment. These tools are used to measure various image parameters, among which spatial resolution shows afundamental property that can be characterized by the Modulation Transfer Function (MTF)of an imaging system [1]. After performing a thorough literature surveyon imaging quality control in digital X film in Argentine and international publications, it was decided to adopt for this work the Norm IEC 62220 1:2003 that recommends using an image edge as a testingmethod. In order to obtain the characterizing MTF, a protocol was designedfor unifying the conditions under which the images are acquired for later evaluation. The protocol implied acquiring a radiography image by means of a specific referential technique, i.e. referred either to voltage, current, time, distance focus plate (/film?) distance, or other referential parameter, and to interpret the image through a system of computed radiology or direct digital radiology. The contribution of the work stems from the fact that, even though the traditional way of evaluating an X film image quality has relied mostly on subjective methods, this work presents an objective evaluative toolfor the images obtained with a givenequipment, followed by a contrastive analysis with the renderings from other X filmimaging sets.Once the images were obtained, specific calculations were carried out. Though there exist some methods based on the subjective evaluation of the quality of image, this work offers an objective evaluation of the equipment under study. Finally, we present the results obtained on different equipment. (paper)

  17. Radiological information management system SRIM-10

    International Nuclear Information System (INIS)

    Shibata, Koichi; Goto, Yoshihisa

    1989-01-01

    A radiological information management system, SRIM-10, has been developed using a personal computer, in order to smoothly manage routine works in radiological division of hospitals. Data base is constructed with radiographic data acuqired directly from x-ray apparatus and patient information acquired using ID card. It is possible to record patient information of about 10,000 patients and radiographic data of about 120,000 exposures. This system can be made up as a multi work station system using a local area network. (author)

  18. Picture archiving and communication systems in radiology

    International Nuclear Information System (INIS)

    Piqueras Pardellans, J.; Carreno Pedemonte, J.C.; Lucaya Layret, J.

    1994-01-01

    Picture archiving and communication systems (PACS) constitute a data processing tool that offers new working methods of diagnostic radiology. The definitive aim of a PACS is to allow a radiology service to operate without film images or documents on paper, integrating images and clinical information. Different image acquisition, viewing and storage systems, linked by communications networks, are arranged around a central management and storage system. Their components are described and the advantages, drawbacks and limitations are discussed from the technological point of view and considering their impact on health care, while a critical review is provided of the 1993 status of this issue

  19. Radiological information management system SRIM-10

    Energy Technology Data Exchange (ETDEWEB)

    Shibata, Koichi; Goto, Yoshihisa

    1989-03-01

    A radiological information management system, SRIM-10, has been developed using a personal computer, in order to smoothly manage routine works in radiological division of hospitals. Data base is constructed with radiographic data acuqired directly from x-ray apparatus and patient information acquired using ID card. It is possible to record patient information of about 10,000 patients and radiographic data of about 120,000 exposures. This system can be made up as a multi work station system using a local area network. (author).

  20. Digital communication system

    Science.gov (United States)

    Monford, L. G., Jr. (Inventor)

    1974-01-01

    A digital communication system is reported for parallel operation of 16 or more transceiver units with the use of only four interconnecting wires. A remote synchronization circuit produces unit address control words sequentially in data frames of 16 words. Means are provided in each transceiver unit to decode calling signals and to transmit calling and data signals. The transceivers communicate with each other over one data line. The synchronization unit communicates the address control information to the transceiver units over an address line and further provides the timing information over a clock line. A reference voltage level or ground line completes the interconnecting four wire hookup.

  1. Guidelines on Training, Examination and Certification in Digital Industrial Radiology Testing (RT-D)

    International Nuclear Information System (INIS)

    2015-01-01

    The IAEA promotes industrial applications of non-destructive testing (NDT) technologies. NDT methods are primarily used for the detection, location and sizing of surface and internal defects in, for example, welds, castings, forging, composite materials and concrete. Various NDT methods are also used in the preventive maintenance of nuclear power plants, aircraft and bridges. Thus, NDT technology contributes significantly to the improvement of the quality of industrial products and the integrity of equipment and plants. The introduction of powerful computers and reliable imaging technology has had significant impact on traditional, nuclear based NDT methods. During the introduction phase in digital industrial radiography (DIR), the digitization of films provided economy of storage, efficiency of communication and accuracy of dimensional measurement. NDT laboratories are progressing rapidly with the digitalization of NDT data. New radiologic imaging techniques in DIR, using image intensifier systems, computed radiography with phosphor imaging plates and digital detector arrays, have increased the capacity for visualization of defects and have revealed new potential for accurate evaluation and measurement. The development of DIR has been of continuing interest to the IAEA and national NDT societies in recent years. This has led to the formation of projects on the development and application of advanced industrial radiography and tomography techniques under the IAEA Regional Co-operative Agreement for Research, Development and Training Related to Nuclear Science and Technology. This publication is intended to provide resource material to support vocational training to NDT radiographers on digital industrial radiography and to help NDT training centres and certification bodies in Member States to establish their own courses, curricula and certification systems in this technology

  2. Microbiological contamination in digital radiography: evaluation at the radiology clinic of an educational institution.

    Science.gov (United States)

    Malta, Cristiana P; Damasceno, Naiana Nl; Ribeiro, Rosangela A; Silva, Carolina Sf; Devito, Karina L

    2016-12-01

    The aim of this study was to evaluate the contamination rate of intra and extraoral digital X ray equipment in a dental radiology clinic at a public educational institution. Samples were collected on three different days, at two times in the day: in the morning, before attending patients, and at the end of the day, after appointment hours and before cleaning and disinfection procedures. Samples were collected from the periapical X-ray machine (tube head, positioning device, control panel and activator button), the panoramic X- ray machine (temporal support, bite block, control panel and activator button), the intraoral digital system (sensor), and the digital system computers (keyboard and mouse). The samples were seeded in different culture media, incubated, and colony forming units (CFU/mL) counted. Biochemical tests were performed for suspected colonies of Staphylococcus, Streptococcus and Gramnegative bacilli (GNB). Fungi were visually differentiated into filamentous fungi and yeasts. The results indicated the growth of fungi and Staphylococcus fromall sampling locations. GNB growth was observed from all sites sampled from the intraoral X-ray equipment. On the panoramic unit, GNB growth was observed in samples from activator button, keyboard and mouse. In general, a higher number of CFU/mL was present before use. It can be concluded that more stringent protocols are needed to control infection and prevent X-ray exams from acting as vehicle for cross contamination. Sociedad Argentina de Investigación Odontológica.

  3. Picture archiving and communication systems for diagnostic radiology

    International Nuclear Information System (INIS)

    Huang, H.K.; Mankovich, N.J.; Kangarloo, H.; Boechat, M.I.; Dietrich, R.; Hall, T.; Taira, R.K.; Cho, P.S.; Stewart, B.K.

    1987-01-01

    The authors developed two picture archiving and communication system (PACS) modules for pediatric radiology and for coronary care unit use. Both modules have been in clinical operation 24 hours a day, 7 days a week, since March 1987. This exhibit presents all components used in these two modules, including a computed radiographic unit, two film laser scanners, a minicomputer, two large processors, one communication system, one digital optical disk library, one six-512-line monitor station, two three 1,024-line monitor stations, a two-2,048-line monitor station, and one laser film printer. The exhibit summarizes clinical evaluations of these two modules

  4. Avoidance of unnecessary dose to patients while transitioning from analogue to digital radiology

    International Nuclear Information System (INIS)

    2011-10-01

    In the last 30-40 years, the pace of innovation in medical imaging has increased, starting with the introduction of computed tomography (CT) in the early 1970s. Since its introduction in the early 1980s, digital radiography has progressed and film-screen systems are steadily being replaced by digital systems, either 'photostimulable' phosphor plates or direct radiography devices. Digital detectors have many advantages, some of which include lower energy requirements, shorter exposure times, possible use of the small focal spot, better dynamic range and greater latitude, almost immediate availability of the images, electronic storage and sharing, no use of chemicals. The radiation dose needed to obtain a similar image quality is lower, but the latitude of the digital systems also allows much higher doses to be delivered without being detected. It is thus very important to ensure that the benefit to be gained from this technology will not be outweighed by radiation risk. Regulation, industrial standardization, safety procedures, and advice on best practice always lag behind industrial and clinical innovations. This monograph is designed to help the medical community make a contribution to dose reduction, preferably without any loss in the level of confidence in the images produced, when replacing their film-screen systems by digital ones. This monograph was developed within the IAEA's statutory framework of responsibility to establish standards for the protection of people against exposure to ionizing radiation, and to provide for the worldwide application of these standards. The Fundamental Safety Principles and the International Basic Safety Standards for Protection against Ionizing Radiation and for the Safety of Radiation Sources (the BSS), issued by the IAEA and co-sponsored by the European Atomic Energy Community, Food and Agriculture Organization of the United Nations, International Labour Organization, International Maritime Organization, OECD Nuclear Energy

  5. Additional diagnostic value of digital radiology in plantar fasciitis diagnosis

    Directory of Open Access Journals (Sweden)

    Marcel Prasetyo

    2017-08-01

    Full Text Available Background: Ultrasonography (USG is regarded as the gold standard to differentiate normal plantar fascia and plantar fasciitis. Conventional radiography or plain X-ray is typically used to exclude differential diagnosis. Lately, conventional radiography has been digitalized and leads to better visualization of the soft tissue. However, it is not known whether digital radiography evaluation for calcaneus area, both qualitative and quantitative, has a similar diagnostic value as USG findings. Therefore, this study aimed to evaluate whether there is a strong correlation between digital radiographic and USG findings for diagnosing plantar fasciitis.Methods: This is a cross sectional study examining adult patients (>18 years old presenting with inferior heel pain. Plantar aponeurosis thickness was measured by digital radiography and ultrasonography; measurement was performed three times in each modality, and the average value was recorded. Fat stranding, presence of calcaneal enthesophyte, and microfracture were also evaluated in digital radiography. Measurement results were classified into plantar fasciitis diagnosis using the cut-off value 4 mm.Results: There was no significant correlation between plantar aponeurosis thickness measured by digital radiography and by ultrasonography (r=0.069, p=0.688. There was no significant association between plantar fasciitis diagnosis by digital radiography and ultrasonography (p=0.162. However, digital radiography showed good sensitivity to detect plantar fasciitis using a cut-off value of >4 mm plantar fascia thickness.Conclusion: Digital radiography might be used to aid definitive diagnosis for plantar fasciitis.

  6. Digital recording system

    International Nuclear Information System (INIS)

    Chandra, A.K.; Deshpande, S.V.; Iyer, A.; Vaidya, U.W.

    1987-01-01

    A large number of critical process parameters in nuclear power plants have hitherto been monitored using electromechanical chart recorders. The reducing costs of electronics systems have led to a trend towards modernizing power plant control rooms by computerizing all the panel instrumentation. As a first step, it has been decided to develop a digital recording system to record the values of 48 process parameters. The system as developed and described in this report is more than a replacement for recorders; it offers substantial advantages in terms of lower overall system cost, excellent time resolution, accurate data and absolute synchronization for correlated signals. The system provides high speed recording of 48 process parameters, maintains historical records and permits retrieval and display of archival information on a colour monitor, a plotter and a printer. It is implemented using a front end data acquisition unit connected on a serial link to a PC-XT computer with 20 MB Winchester. The system offers an extremely user friendly man machine interaction, based on a hierarchical paged menu driven scheme. Softwre development for this system has been carried out using the C language. (author). 9 figs

  7. Digital control systems. Verteilte Prozessleitsysteme

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    With a distinct description of the systems properties thin regulation shall provide a latter transparency for the use of digital control systems. The application of the new technique shall be facilitated, incitations for the further development shall be given and the compatibility of the systems shall be advanced. Moreover, the regulation can be used as criteria catalogue for the evaluation of digital systems.

  8. Informatics in radiology: web-based preliminary reporting system for radiology residents with PACS integration.

    Science.gov (United States)

    O'Connell, Timothy; Chang, Debra

    2012-01-01

    While on call, radiology residents review imaging studies and issue preliminary reports to referring clinicians. In the absence of an integrated reporting system at the training sites of the authors' institution, residents were typing and faxing preliminary reports. To partially automate the on-call resident workflow, a Web-based system for resident reporting was developed by using the free open-source xAMP Web application framework and an open-source DICOM (Digital Imaging and Communications in Medicine) software toolkit, with the goals of reducing errors and lowering barriers to education. This reporting system integrates with the picture archiving and communication system to display a worklist of studies. Patient data are automatically entered in the preliminary report to prevent identification errors and simplify the report creation process. When the final report for a resident's on-call study is available, the reporting system queries the report broker for the final report, and then displays the preliminary report side by side with the final report, thus simplifying the review process and encouraging review of all of the resident's reports. The xAMP Web application framework should be considered for development of radiology department informatics projects owing to its zero cost, minimal hardware requirements, ease of programming, and large support community.

  9. Radiological features of a fibro-osseous pseudotumor in the digit: A case report

    International Nuclear Information System (INIS)

    Kwak, Min Jae; Kim, Sun Ki; Lee, Sang Uk; Jun, Sun Young; Lee, An Hi

    2015-01-01

    A fibro-osseous pseudotumor is a rare ossifying soft tissue lesion, which is thought to be a reactive rather than a neoplastic lesion, developing due to repeated trauma. The lesion mostly occurs in the subcutaneous tissue of the proximal phalanx of the digit and predominantly affects young adults, with a slight predominance in females. The clinicopathological features can mimic those of malignant soft tissue lesions, and diagnosis can be difficult. Less is known about the radiological appearance of the lesion, including magnetic resonance imaging (MRI) features, than about histological signs. Here, we report radiological findings, including MRI features, of a fibro-osseous pseudotumor of the digit in a young female

  10. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2004-01-01

    The development of new radiological protection recommendations by the International Commission on Radiological Protection (ICRP) continues to be a strategically important undertaking, both nationally and internationally. With the growing recognition of the importance of stakeholder aspects in radiological protection decision making, regional and cultural aspects have also emerged as having potentially significant influence on how protection of the public, workers and the environment are viewed. Differing cultural aspects should therefore be considered by the ICRP in its development of new recommendations. Based on this assumption, the NEA organised the Asian Regional Conference on the Evolution of the System of Radiological Protection to express and explore views from the Far East. Held in Tokyo on 24-25 October 2002, the conference included presentations by the ICRP Chair as well as by radiological protection experts from Japan, the Republic of Korea, China and Australia. The distinct views and needs of these countries were discussed in the context of their regional and cultural heritages. These views, along with a summary of the conference results, are presented in these proceedings. (author)

  11. Investigation of possible methods for equipment self-tests in digital radiology

    International Nuclear Information System (INIS)

    Zoetelief, J.; Idris, H. H. E.; Jansen, J. T. M.

    2005-01-01

    Quality control in digital radiology can be time-consuming. Equipment self-tests may significantly decrease staff workload. The two most essential parameters for radiology systems are image quality and patient dose. Concerning patient dose, information on the dose-area product (DAP) values generally forms the basis for assessment of patient dose. DAP-values can be measured using a transmission ionisation chamber or calculated from equipment settings. In the present study, various image quality parameters were derived using a contrast-detail (C-D) phantom. The investigation included a computer-aided assessment of C-D images, which produced various parameters, and also parameters based upon scoring by human observers. In addition, another parameter was calculated from modulation transfer function (MTF) measurements. The automatically calculated parameters showed good correlation with human readings, although the number of X-ray systems studied is still limited. We propose a combined evaluation of DAP and automatically calculated C-D or MTF parameters for equipment self-tests. (authors)

  12. Radiological/biological/aerosol removal system

    Science.gov (United States)

    Haslam, Jeffery J

    2015-03-17

    An air filter replacement system for existing buildings, vehicles, arenas, and other enclosed airspaces includes a replacement air filter for replacing a standard air filter. The replacement air filter has dimensions and air flow specifications that allow it to replace the standard air filter. The replacement air filter includes a filter material that removes radiological or biological or aerosol particles.

  13. Losing Images in Digital Radiology: More than You Think

    OpenAIRE

    Oglevee, Catherine; Pianykh, Oleg

    2014-01-01

    It is a common belief that the shift to digital imaging some 20 years ago helped medical image exchange and got rid of any potential image loss that was happening with printed image films. Unfortunately, this is not the case: despite the most recent advances in digital imaging, most hospitals still keep losing their imaging data, with these losses going completely unnoticed. As a result, not only does image loss affect the faith in digital imaging but it also affects patient diagnosis and dai...

  14. Assessment of uniformity and signal-to-noise ratio in radiological image intensifier TV systems

    International Nuclear Information System (INIS)

    Malone, J.F.; O'Connor, M.K.; Maher, K.P.

    1985-01-01

    A method of measuring the uniformity of radiological Image Intensifier-TV systems is described. Large non-uniformities were observed in the systems tested. A method of estimating the Signal-to-Noise Ratio in such systems is also presented and applied to characterise the effectiveness of the noise reduction techniques used in digital fluoroscopy. (author)

  15. Digital and conventional radiology techniques: comparison of dosage and costs

    International Nuclear Information System (INIS)

    Arranza, L.; Albornoz, C. de

    1996-01-01

    To compare the radiation dosage and costs in conventional and digital technologies. The study dealt with transverse sections. The dosage applied with conventional technology was measured in 254 patients who intertwined 402 explorations of 6 anatomic regions in 4 Radiodiagnostic Services. The dosage applied with digital technology was measured in 57 patients who underwent 95 explorations of the same anatomic region in one Radiodiagnostic Service. The costs of the 6 types of conventional and digital explorations performed were calculated for two Radiodiagnostic Service. The doses administered (mGy) using convectional/digital technology were as follows: chest PA 0.2/0.1; chest LAT 0.7/0.3; breast CC 7.0/8.4; breast LAT 7.0/7.8; breast OB 7.0/10.5; cervical spine AP 9.6/9.0; cervical spine LAT 21.9/29.6; pelvis AP 7.3/7.1; plain abdominal 6.5/2.2. The costs incurred (1992 pesetas) with the convectional/digital technologies: chest AP and LAT 1,393/2,973; portable chest 2,027/3,714; mammography 2,357/3,486; phlebography 12,718/14,023; hysterosalpingography 4,876/6,701; bone scientigraphy 1,633/2,839. Compared with conventional technology, digital imaging reduces the radiation doses received by the patients, except in the case of mammography. The costs associated with the use of digital technology are greater than those incurred with conventional technology, mainly due to the costs of amortization. the use of digital technology is more justified when: 1) it is very necessary to reduce the dosage; 2) studies of chest and abdomen predominant; 3) the volume of utilization is high; 4) staff management is flexible , and 5) the cost of purchasing the equipment is lower. (Author) 10 refs

  16. Digital integrated protection system

    International Nuclear Information System (INIS)

    Savornin, M.; Furet, M.

    1978-01-01

    As a result of technological progress it is now possible to achieve more elaborate protection functions able to follow more closely the phenomena to be supervised. For this reason the CEA, Framatome and Merlin/Gerin/CERCI have undertaken in commonn to develop a Digital Integrated Protection System (D.I.P.S.). This system is designed with the following aims: to improve the safety of the station, . to improve its availability, . to facilitate installation, . to facilitate tests and maintenance. The main characteristics adopted are: . possibilities of obtaining more elaborate monitoring and protection algorithm treatments, . order 4 redundancy of transducers, associated instruments and signal processing, . possibility of inhibiting part of the protection system, . standardisation of equipment, physical and electrical separation of redundant units, . use of multiplexed connections, . automation of tests. Four flow charts are presented: - DIPS with four APUP (Acquisition and Processing Unit for Protection) - APUP - LSU (Logic Safeguard Unit), number LSU corresponding to number fluidic safeguard circuits, - structure of a function unit, - main functions of the APUP [fr

  17. Digital technology influence on patient dose in the radiological examination of the upper digestive apparatus

    International Nuclear Information System (INIS)

    Nunez, E.; Pifarre, X.; Ruiz, J.; Escalada, C.; Paredes, M.C.

    2001-01-01

    The radiological study of the superior digestive apparatus (oesophagus, stomach and duodenum) throughout the barium contrast is a kind of exploration which provides medium-high dosage levels for patients. In these studies the fluoroscopy and the acquisition of images for the diagnosis are shared. The acquisition of images, up until a few years ago, was accomplished through radiographic film and chemical processing; nowadays, the new generation of image-intensifier tube incorporates a new utility to digitally capture the images. This new capturing method, with higher sensitivity, allows us to obtain images with a mAs 5 times smaller than the classical system of radiological film (reduction of the dosage up to 80%). This leads us to expect very important reductions in dosage in the studies conducted with this new technology. Nonetheless, these expectations haven't been reflected in the dosimetric samples that our work team has conducted in several centers of the community of Madrid these past years. In this work, the reasons for this phenomenon are analyzed. (author)

  18. Implementation of DICOM Modality Worklist at Patient Registration Systems in Radiology Unit

    Science.gov (United States)

    Kartawiguna, Daniel; Georgiana, Vina

    2014-03-01

    Currently, the information and communication technology is developing very rapidly. A lot of hospitals have digital radiodiagnostic modality that supports the DICOM protocol. However, the implementation of integrated radiology information system with medical imaging equipment is still very limited until now, especially in developing countries like Indonesia. One of the obstacles is high prices for radiology information system. Whereas the radiology information systems can be widely used by radiologists to provide many benefit for patient, hospitals, and the doctors themselves. This study aims to develop a system that integrates the radiology administration information system with radiodiagnostic imaging modalities. Such a system would give some benefits that the information obtained is more accurate, timely, relevant, and accelerate the workflow of healthcare workers. This research used direct observation method to some hospital radiology unit. Data was collected through interviews, questionnaires, and surveys directly to some of the hospital's radiology department in Jakarta, and supported by the literature study. Based on the observations, the prototype of integrated patient registration systems in radiology unit is developed and interfaced to imaging equipment radiodiagnostic using standard DICOM communications. The prototype of radiology patient registration system is tested with the modality MRI and CT scan.

  19. Systemic lupus erythematosus : abdominal radiologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Jae Cheon; Cho, On Koo; Lee, Yong Joo; Bae, Jae Ik; Kim, Yong Soo; Rhim, Hyun Chul; Ko, Byung Hee [Hanyang Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-06-01

    Systemic lupus erythematosus(SLE) is a systemic disease of unknown etiology. Its main pathology is vasculitis and serositis, due to deposition of the immune complex or antibodies. Most findings are nonspecific ; abdominal manifestations include enteritis, hepatomegaly, pancreatic enlargement, serositis, lymphadenopathy, splenomegaly, nephritis, interstitial cystitis, and thrombophlebitis. We described radiologic findings of various organ involvement of SLE; digestive system, serosa, reticuloendothelial system, urinary system, and venous system. Diagnosis of SLE was done according to the criteria of American Rheumatism Association. Understanding of the variable imaging findings in SLE may be helpful for the early detection of abdominal involvement and complications.

  20. Radiology

    International Nuclear Information System (INIS)

    Bigot, J.M.; Moreau, J.F.; Nahum, H.; Bellet, M.

    1990-01-01

    The 17th International Congress of Radiology was conducted in two separate scientific sessions, one for radiodiagnosis and one for radiation oncology. Topics covered are: Radiobiology -radioprotection; imaging and data processing; contrast media; MRI; nuclear medicine; radiology and disasters; radiology of tropical diseases; cardiovascular radiology; interventional radiology; imaging of trauma; imaging of chest, gastro-intestinal tract, breast and genito-urinary tract; imaging in gynecology;imaging in oncology; bone and joint radiology; head and neck-radiology; neuro-radiology. (H.W.). refs.; fig.; tabs

  1. Radiological protection system in the era of nuclear renaissance expectation for development of radiological protection system

    International Nuclear Information System (INIS)

    Toyomatsu, Hideki

    2008-01-01

    The current radiological protection system, which was established mainly by the ICRP and UNSCEAR, has contributed to the prevention of potential radiological health hazards, and has been a fundamental concept during the development of nuclear energy. Through a detailed discussion regarding the new ICRP recommendations, the world nuclear industry has reached a consensus that the current radiological protection system keeps its integrity in principle although it involves some remaining issues, such as the disposal of radioactive waste. In order to maximize the advantages of nuclear energy while keeping the integrity of radiological protection system, it is essential to address the characteristics of radiation, which is specific to nuclear energy, so that nuclear energy can coexist with other energy sources. The three basic principles of radiological protection (i.e., justification, optimization and dose limits), which were completed in the 1990 recommendations of ICRP, should be retained as the basic concepts for the future radiological protection system in order to maintain the continuity and consistency of the radiological protection system. The radiological protection system can be furthermore developed only by combining the above three principles with best practices extracted from utilities' field experience. The significant reduction of radiation exposures received by members of the public and radiation workers in the field has resulted from the efforts by the world utilities to achieve the optimization. In order to correctly apply the theory to the work practices, it is essential to see how the theory is practically used in the field. Such a process should be also emphasized in the revision work of the IAEA Basic Safety Standards (BSS), which is currently under progress. Integrating the theory in the work practices is the key to the true development of nuclear renaissance, which could lead to the establishment of the nuclear safety regime. (author)

  2. Comparison of root canal lathing measurement by conventional and digital radiology

    International Nuclear Information System (INIS)

    Mitrova, N.; Slavik, J.; Cecetkova, A.; Jenca, A.; Hanusinova, V.; Ondrasovicova, J.

    2006-01-01

    A correct working length is a critical factor within the endodontic treatment. The length of the root canal can be measured by different methods. The aim of this study was to compare methods used for measuring the length of root canals using conventional and digital radiology. The measurement was provided in both - in vitro and in vivo conditions. (authors)

  3. Losing images in digital radiology: more than you think.

    Science.gov (United States)

    Oglevee, Catherine; Pianykh, Oleg

    2015-06-01

    It is a common belief that the shift to digital imaging some 20 years ago helped medical image exchange and got rid of any potential image loss that was happening with printed image films. Unfortunately, this is not the case: despite the most recent advances in digital imaging, most hospitals still keep losing their imaging data, with these losses going completely unnoticed. As a result, not only does image loss affect the faith in digital imaging but it also affects patient diagnosis and daily quality of clinical work. This paper identifies the origins of invisible image losses, provides methods and procedures to detect image loss, and demonstrates modes of action that can be taken to stop the problem from happening.

  4. Clinical applications of SONIALVISION 100 digital diagnostic table system

    International Nuclear Information System (INIS)

    Shiomi, Takeshi; Shimizu, Tatsuya; Iinuma, Masao; Takemoto, Hajime; Tanaka, Shuji

    2003-01-01

    This report refers to the clinical applications of our newly developed SONIALVISION 100 fully digitalized X-ray diagnostic table system. The main design concept of the SONIALVISION 100 system is the improvement of workflow in various clinical fields. The development of digital imaging technologies has come to allow fully digitalized X-ray diagnostic table systems to be widely utilized in various clinical applications, including interventional radiology (IVR) and examinations using contrast medium. This report mainly refers to the clinical applications of the Shimadzu SONIALVISION 100 digitalized X-ray diagnostic table system, also presenting some typical image data demonstrating the high efficiency, made available through the use of this new system, in high-speed spot imaging and digital tomography. (author)

  5. An Advanced Radiological Survey and Mapping System

    International Nuclear Information System (INIS)

    McCown, J.; Rogers, D.; Waggoner, Ch.

    2009-01-01

    A variety of radiological surveying systems have been described in the literature. This paper describes relative performances of a system that can employ a variety of radiological sensors including NaI, LiI, and LaBr 3 units of various sizes. The system includes navigation and data collection software that facilitates surveying without the use of survey grid-lines. Parameters presented to the operator via a graphical user interface (GUI) for monitoring system performance and navigation are described. Radiological spectra are logged along with position data from three differential GPS sensors to enhance position accuracy by taking into account the pitch and roll as the survey vehicle moves over uneven terrain. Accuracy of position data increases the potential for, and value of, data fusion with other survey data such as electromagnetic induction images. The survey system described has been developed around a zero turn radius lawn mower equipped with on-board generator/inverter for powering electronic and data communication equipment to maximize surveying effectiveness. Detection limits for U-238 will be discussed for the NaI (FIDLER, 75x75 mm, and 100x100x400 mm) and LaBr 3 (75x75 mm) detectors. These parameters will be reported for a variety of survey speeds (stationary, 1, 2, and 3 m/s), with and without the use of advanced signal processing to increase detection sensitivity. A background subtraction algorithm evaluating each spectrum for the presence of naturally occurring radiological materials will also be described for correcting each datum prior to mapping using Geosoft Oasis montaj. (authors)

  6. Basic demands for radiological information systems (RIS)

    International Nuclear Information System (INIS)

    Traupe, H.; Purgold, S.

    1993-01-01

    One of the most important problems in medicine today is quality control and the achievement of a cost-benefit analysis in the areas of both treatment and diagnosis. With modern software techniques, complex relations between medical and aministrative data can be shown up and analysed. Preconditions are a vocabulary that can be processed by computer for medical facts and decisions and a database system capable of collecting a large amount of heterogeneous data and costing everything precisely. We have developed an object description language and, on the basis of the relational database approach, a complex system covering most aspects of medical and administrative data handling in radiology. The basic demands and elements of modern information handling in radiology are described and discussed. (orig.) [de

  7. Airborne systems for emergency radiological monitoring

    International Nuclear Information System (INIS)

    Jupiter, C.; Boyns, P.

    1976-01-01

    A variety of aerial radiological monitoring systems are available to respond to a radiological accident or incident affecting large areas. These are operated by EG and G, Inc. for ERDA's Division of Operational Safety. A survey system can be airborne within approximately two hours after notification. Both airborne and terrestrial radioactivity can be measured and mapped. Special analysis procedures allow discrimination between radioactivity from most man-made radioelements and naturally occurring radioelements. A position accuracy of +-54 feet can be maintained over a large area survey. Detection sensitivity for gamma sources employing NaI detector arrays on board an airplane flying at 500 feet altitude is better than 2 μR/hr for surface planar contaminants and approximately 10 mCi for a point gamma source

  8. [Analog gamma camera digitalization computer system].

    Science.gov (United States)

    Rojas, G M; Quintana, J C; Jer, J; Astudillo, S; Arenas, L; Araya, H

    2004-01-01

    Digitalization of analogue gamma cameras systems, using special acquisition boards in microcomputers and appropriate software for acquisition and processing of nuclear medicine images is described in detail. Microcomputer integrated systems interconnected by means of a Local Area Network (LAN) and connected to several gamma cameras have been implemented using specialized acquisition boards. The PIP software (Portable Image Processing) was installed on each microcomputer to acquire and preprocess the nuclear medicine images. A specialized image processing software has been designed and developed for these purposes. This software allows processing of each nuclear medicine exam, in a semiautomatic procedure, and recording of the results on radiological films. . A stable, flexible and inexpensive system which makes it possible to digitize, visualize, process, and print nuclear medicine images obtained from analogue gamma cameras was implemented in the Nuclear Medicine Division. Such a system yields higher quality images than those obtained with analogue cameras while keeping operating costs considerably lower (filming: 24.6%, fixing 48.2% and developing 26%.) Analogue gamma camera systems can be digitalized economically. This system makes it possible to obtain optimal clinical quality nuclear medicine images, to increase the acquisition and processing efficiency, and to reduce the steps involved in each exam.

  9. Digital processing data communication systems (bus systems)

    International Nuclear Information System (INIS)

    Fleck, K.

    1980-01-01

    After an introduction to the technology of digital processing data communication systems there are the following chapters: digital communication of processing data in automation technology, the technology of biserial communication, the implementaiton of a bus system, the data transmission of the TDC-2000 system of Honeywell's and the process bus CS 275 in the automation system TELEPERM M of Siemens AG. (WB) [de

  10. Dose classification scheme for digital imaging techniques in diagnostic radiology

    International Nuclear Information System (INIS)

    Hojreh, A.

    2002-04-01

    Purpose: image quality in diagnostic radiology is determined in crucial extent by the signal-noise-ratio, which is proportional to the applied x-ray dose. Onward technological developments in the diagnostic radiology are therefore frequently connected with a dose increase, which subjectively is hardly or even not perceptible. The aim of this work was to define reproducible standards for image quality as a function of dose and expected therapeutical consequence in case of computed tomography of the paranasal sinuses and the upper and lower jaw (dental CT), whereby practical-clinical purposes are considered. Materials and methods: the image quality of computed tomography of the paranasal sinuses and dental CT was determined by standard deviation of the CT-numbers (pixel noise) in a region of interest of the phantom of American Association of Physicists in Medicine (AAPM phantom) and additionally in the patients CT images. The diagnostic quality of the examination was classified on the basis of patients CT images in three dose levels (low dose, standard dose and high dose). Results: the pixel noise of CT of the paranasal sinuses with soft tissue reconstruction amounts to 19.3 Hounsfield units (HU) for low dose, 8.8 HU for standard dose, and below 8 HU for high dose. The pixel noise of the dental CT with bone (high resolution) reconstruction amounts to 344 HU for low dose, 221 HU for standard dose, and below 200 HU for high dose. Suitable indications for low dose CT are the scanning of body regions with high contrast differences, like the bony delimitations of air-filled spaces of the facial bones, and radiological follow-up examinations with dedicated questions such as axis determination in dental implantology, as well as the images of objects with small diameter such as in case of children. The standard dose CT can be recommended for all cases, in which precise staging of the illness plays an indispensable role for the diagnosis and therapy planning. With high dose

  11. Digital video applications in radiologic education: theory, technique, and applications.

    Science.gov (United States)

    Hennessey, J G; Fishman, E K; Ney, D R

    1994-05-01

    Computer-assisted instruction (CAI) has great potential in medical education. The recent explosion of multimedia platforms provides an environment for the seemless integration of text, images, and sound into a single program. This article discusses the role of digital video in the current educational environment as well as its future potential. An indepth review of the technical decisions of this new technology is also presented.

  12. Digital fluorographic method and system

    International Nuclear Information System (INIS)

    Ledley, R.S.

    1985-01-01

    This invention relates to a digital fluorographic method and system, in particular a method and system which calls for the digitization and storage of first and second x-ray picture data derived before and after injection of a contrast medium into a subject. The digitized pictures are stored in separate memories in an associated system, and can be separately whole-picture processed to develop corresponding processed picture data. The resulting data are subtractively combined to produce data corresponding to a pictorial representation of differences between the x-ray picture before and after injection of the contrast medium

  13. Recommendations for equipment requirements and specifications for digital and interventional radiology: Dosimetric aspects

    International Nuclear Information System (INIS)

    Suliman, I.I.; Zoetelief, J.

    2002-01-01

    The recognition of radiation induced injuries from fluoroscopically guided interventional procedures has resulted in the current demand for development of recommendations and standards to limit dose to both patients and staff. This paper outlines the recommendations drafted within the framework of European Project DIMOND III. The actual work involves survey and review of national and international documents as well as scientific publications in areas relevant to the digital and/or interventional radiology with an aim of developing recommendations for equipment requirements and specifications for digital and interventional radiology. A pilot study of experimental investigations in at least three hospitals will be conducted to test the requirements and the specifications, the result of which will be presented. The recommendations are expected to provide an effective means of dose reduction to both patients and staff while maintaining image quality adequate for the specific diagnosis or interventional procedure. Different components of x-ray systems that have direct impact on patient and staff doses have been considered. Where necessary a compromise between patient dose and image quality has been made. The dosimetric aspects of the recommendations propose detailed descriptions and limits to dosimetric information relevant to patient and staff doses. International recommendations on maximum patient entrance surface dose rate vary in the range from 25 to 65 mGy.min -1 for normal mode fluoroscopy. Maximum image intensifier or image receptor input dose rate around 0.1 Gy min -1 at a distance 30 cm from the image intensifier input surface has been generally recommended. Maximum fluoroscopic dose rate in air must not exceed 50 mGy.min -1 at a location depending on the configuration e.g. for undertable x-ray tube at 10 mm from the patient support on the patient side of the support. The use of pulsed fluoroscopy or low dose fluoroscopy is proposed as good options to minimize

  14. Offsite emergency radiological monitoring system and technology

    International Nuclear Information System (INIS)

    Mao Yongze

    1994-01-01

    The study and advance of the offsite radiological monitoring system and technology which is an important branch in the field of nuclear monitoring technology are described. The author suggests that the predicting and measuring system should be involved in the monitoring system. The measuring system can further be divided into four sub-systems, namely plume exposure pathway, emergency worker, ingestion exposure pathway and post accident recovery measuring sub-systems. The main facilities for the monitoring system are concluded as one station, one helicopter, one laboratory and two vehicles. The instrumentation for complement of the facilities and their good performance characteristics, up-to-date technology are also introduced in brief. The offsite emergency radiation monitoring system and technology are compared in detail with those recommended by FEMA U.S.A.. Finally the paper discusses some trends in development of emergency radiation monitoring system and technology in the developed countries

  15. Full-field digital mammography versus computed radiology mammography: comparison in image quality and radiation dose

    International Nuclear Information System (INIS)

    Zhao Yongxia; Song Shaojuan; Liu Chuanya; Qi Hengtao; Qin Weichang

    2008-01-01

    Objective: To investigate the differences in image quality and radiation dose between full- field digital mammography (FFDM) system and compute radiology mammography (CRM) system. Methods: The ALVIM mammographic phantom was exposed by FFDM system with automatic exposure control (AEC) and then exposed by CRM system with the unique imaging plank on the same condition. The FFDM system applied the same kV value and the different mAs values (14, 16, 18, 22 and 24 mAs), and the emission skin dose (ESD) and the average gland dose (AGD) were recorded for the above-mentioned exposure factors. All images were read by five experienced radiologists under the same condition and judged based on 5-point scales. And then receive operating characteristic (ROC) curve was drawn and the probability (P det ) values were calculated. The data were statistically processed with ANOVA. Results: The P det values of calcifications and lesion lump were higher with FFDM system than with CRM system at the same dose (1.36 mGy). Especially, for microcalcifications and lesion lump, the largest difference of the P det value was 0.215, and that of lesion lump was 0.245. In comparison with CRM system, the radiation dose of FFDM system could be reduced at the same P det value. The ESD value was reduced by 26%, and the ACD value was reduced by 41%. When the mAs value exceed AEC value, the P det value almost had no change, though the radiation dose was increased. Conclusions: The detection rates of microcalcifications and lesion lump with FFDM system are proven to be superior to CRM system at the same dose. The radiation dose of FFDM system was less than CRM system for the same image quality. (authors)

  16. Radiological investigation of renovascular hypertension from IVU to digital subtraction angiography. A critical evaluation

    International Nuclear Information System (INIS)

    Amiel, M.; Froment, A.; Pinet, F.; Huguet, M.

    1986-01-01

    For the last 20 years, the value of radiology in renovascular hypertension (RVH) is well established from diagnostic and therapeutic points of view. However things are changing now due to a better appraisal of the incidence of RVH, new antihypertensive drugs, and new radiological procedures (digital angiography, percutaneous transluminal angioplasty). The approach now takes in account the mode of imaging for a better evaluation of the renal artery stenosis and costs of the proceedings as well. Finally a new strategy has been set up for RVH patients management [fr

  17. Radiology system evolution in the new millennium.

    Science.gov (United States)

    Nauert, R C

    2001-01-01

    For many decades the practice of radiology grew slowly in America and was largely a secondary function under the control of hospitals. In more recent times it has vastly expanded its array of diagnostic, interventional, and therapeutic abilities. There is increasing consumer logic for direct access. Motivations have grown to create large independent entities with broadly diverse capabilities in order to succeed in the new millennium. Most regional markets are evolving rapidly in terms of managed care penetration, health system formation, physician practice consolidation and aggressive purchaser behavior by employers and consumers. To understand the enormity of healthcare evolution, it is useful to look at the industry's paradigm shifts in recent decades. Virtually every aspect of organizational infrastructure, delivery approaches, and the business environment has evolved markedly during the past fifty years. These changes will accelerate. To succeed financially, radiology groups must strengthen their market positions, technical capabilities, continuums of care and geographic dominance. Equally important is the wisdom of diversifying incomes into related services and businesses that provide additional related revenues. Key factors for successful development include facility market growth, full coverage of managed care contracts, high efficiency and aggressive diversification. A fully evolved system generates significant revenues and profitability by protecting and strengthening its financial position in this environment. That is accomplished through the development of strategically located radiology groups, aggressive alliances with medical practices in allied disciplines, and managed radiology departments and facilities for partner health systems. Organizational success ultimately depends on the ability to accept capitated payments under risk-bearing arrangements. The strategic business plan should be organized with the appropriate levels of detail needed to

  18. Digital LLRF System for RFQ

    International Nuclear Information System (INIS)

    Agashe, Alok; Motiwala, P.D.; Bharade, S.K.; Mohan, Shyam; Joshi, Gopal; Das, D.

    2015-01-01

    A Low level RF (LLRF) system based on digital techniques has been developed for RFQ of Low Energy High Intensity Proton Accelerator (LEHIPA). The basic LLRF system for RFQ is composed of a Front end analog module housed in a 19 inch bin and a 6U cPCI based Digital board having a high speed and high density FPGA onboard, supporting 32 bit/33MHz PCI ver2.0 protocol and housed in a 19 inch cPCI crate. It also has a cPCI based CPU board with QNX operating system. The cPCI crate is connected to control room via Ethernet. Analog module conditions the input field signals from RF cavity and makes it compatible to digital board. It also amplifies RF Drive signal (Modulator output) from digital board, which goes to high power amplifier. The digital board digitally processes the input RF signals, and generates RF drive signal, which after amplification, used for driving the resonant cavity. The main features of digital board are under-sampling of input RF signals, digital in-phase and quadrature detection, and a proportional- integral (PI) controller algorithm implemented in a FPGA. The LLRF system works in CW as well as in PULSE mode. It also has a DDS implemented in VHDL, used for conditioning and tracking/tuning of the cavity. LLRF system operates under QNX based equipment frontend application and client running from control room. One analog module and one digital board set, supports one resonant cavity. The present paper describes the development of an LLRF system and its results with a test cavity. (author)

  19. Overview of the aerial radiological measuring system (ARMS) program

    International Nuclear Information System (INIS)

    Deal, L.J.; Doyle, J.F. III.

    1975-01-01

    Since 1960 EG and G, Inc. has developed and maintained for the U.S. Energy Research and Development Administration (ERDA) a state-of-the-art radiation surveillance program called the Aerial Radiological Measuring System (ARMS). Radiological surveys covering more than 300,000 square miles have been performed. In addition to the radiation detector gear, the system includes an inertial navigation system, radar altimeter, meteorological probes, air sampler, air sample analyzer, multispectral cameras, aerial mapping camera and infrared scanner. The recently improved data acquisition system, REDAR, records all inputs digitally on magnetic tape and is readily mounted in fixed-wing aircraft or helicopters. The data analysis system, REDAC, is mounted in a mobile processing laboratory which accompanies the aircraft on surveys. Radiation isopleth maps, both for gross counts and selected isotopes, can be prepared in the field. Special computer software enables the ARMS to detect changes of less than 1.0 μR/hr in exposure rates between successive surveys of a given site

  20. IT services in a completely digitized radiological department: value and benefit of an in-house departmental IT group

    International Nuclear Information System (INIS)

    Treitl, M.; Wirth, S.; Lucke, A.; Rieger, J.; Pfeifer, K.J.; Reiser, M.; Villain, S.

    2005-01-01

    To analyze the benefit of a departmental IT group in comparison to support by hospital IT groups or system manufacturers in a completely digitized radiological department. The departmental IT group comprises a fulltime IT specialist, two student assistants and four clinical employees participating 1 day/week. For 18 months IT problems were quantified and specified according to urgency, responsibility and affected system by use of an intranet-based reporting system. For each IT service provider the performance and duration of problem solution was evaluated. In 18 months 3,234 IT problems emerged. 88.7% were solved by the departmental IT group. In 474 cases (14.7%) a solution within 2 h was required. The departmental IT group solved 35.8% within 30 min, system manufacturers needed 18 h 38 min in mean. The departmental IT group solved 90.2% of the problems within a time limit. System manufacturers met the limit in 60.1% with a mean duration of 7 days 21 h. In 6.7% of the cases, support by system manufacturers was indispensable. A considerable proportion of IT problems in completely digitized radiological departments can be solved by a departmental IT group, providing a fast and cost-efficient first-level IT support with effective prevention of major breaks in the workflow. In a small number of cases support by system manufacturers remains necessary. (orig.)

  1. Description of an acquisition, management and archiving system for digital images

    International Nuclear Information System (INIS)

    Andre, M.; Agostini, S.; Clement, J.P.; Giaccone, A.; Lefevre, C.

    1990-01-01

    A digitalizing and archiving system, for radiologic pictures is presented. This system is composed by a camera, a microcomputer (Maclntosh II) with a digitalizing card and a great capacity optical disk (WORM) for storage. Acquiring and archiving are automatically driven by a special soft. The principal qualities of this system are simplicity for the user, speed and low cost [fr

  2. Radiology

    International Nuclear Information System (INIS)

    Edholm, P.R.

    1990-01-01

    This is a report describing diagnostic techniques used in radiology. It describes the equipment necessary for, and the operation of a radiological department. Also is described the standard methods used in radiodiagnosis. (K.A.E.)

  3. Development of a user-centered radiology teaching file system

    Science.gov (United States)

    dos Santos, Marcelo; Fujino, Asa

    2011-03-01

    Learning radiology requires systematic and comprehensive study of a large knowledge base of medical images. In this work is presented the development of a digital radiology teaching file system. The proposed system has been created in order to offer a set of customized services regarding to users' contexts and their informational needs. This has been done by means of an electronic infrastructure that provides easy and integrated access to all relevant patient data at the time of image interpretation, so that radiologists and researchers can examine all available data to reach well-informed conclusions, while protecting patient data privacy and security. The system is presented such as an environment which implements a distributed clinical database, including medical images, authoring tools, repository for multimedia documents, and also a peer-reviewed model which assures dataset quality. The current implementation has shown that creating clinical data repositories on networked computer environments points to be a good solution in terms of providing means to review information management practices in electronic environments and to create customized and contextbased tools for users connected to the system throughout electronic interfaces.

  4. [Research applications in digital radiology. Big data and co].

    Science.gov (United States)

    Müller, H; Hanbury, A

    2016-02-01

    Medical imaging produces increasingly complex images (e.g. thinner slices and higher resolution) with more protocols, so that image reading has also become much more complex. More information needs to be processed and usually the number of radiologists available for these tasks has not increased to the same extent. The objective of this article is to present current research results from projects on the use of image data for clinical decision support. An infrastructure that can allow large volumes of data to be accessed is presented. In this way the best performing tools can be identified without the medical data having to leave secure servers. The text presents the results of the VISCERAL and Khresmoi EU-funded projects, which allow the analysis of previous cases from institutional archives to support decision-making and for process automation. The results also represent a secure evaluation environment for medical image analysis. This allows the use of data extracted from past cases to solve information needs occurring when diagnosing new cases. The presented research prototypes allow direct extraction of knowledge from the visual data of the images and to use this for decision support or process automation. Real clinical use has not been tested but several subjective user tests showed the effectiveness and efficiency of the process. The future in radiology will clearly depend on better use of the important knowledge in clinical image archives to automate processes and aid decision-making via big data analysis. This can help concentrate the work of radiologists towards the most important parts of diagnostics.

  5. Effect of immediate feedback training on observer performance on a digital radiology workstation

    International Nuclear Information System (INIS)

    Mc Neill, K.M.; Maloney, K.; Elam, E.A.; Hillman, B.J.; Witzke, D.B.

    1990-01-01

    This paper reports on testing the hypothesis that training radiologists on a digital workstation would affect their efficiency and subjective acceptance of radiologic interpretation based on images shown on a cathode ray tub (CRT). Using a digital radiology workstation, six faculty radiologists and four senior residents read seven groups of six images each. In each group, three images were ranked as easy and three were ranked as difficult. All images were abnormal posteroanterior chest radiographs. On display of each image, the observer was asked which findings were present. After the observer listed his or her findings, the experimenter listed any findings not mentioned and pointed out any incorrect findings. The time to finding was recorded for each image, along with the number of corrections and missed findings. A postexperiment questionnaire was given to obtain subjective responses from the observers

  6. Diagnostic imaging, a 'parallel' discipline. Can current technology provide a reliable digital diagnostic radiology department

    International Nuclear Information System (INIS)

    Moore, C.J.; Eddleston, B.

    1985-01-01

    Only recently has any detailed criticism been voiced about the practicalities of the introduction of generalised, digital, imaging complexes in diagnostic radiology. Although attendant technological problems are highlighted the authors argue that the fundamental causes of current difficulties are not in the generation but in the processing, filing and subsequent retrieval for display of digital image records. In the real world, looking at images is a parallel process of some complexity and so it is perhaps untimely to expect versatile handling of vast image data bases by existing computer hardware and software which, by their current nature, perform tasks serially. (author)

  7. Rassyn: National radiological safety data management system

    International Nuclear Information System (INIS)

    Domenech Nieves, Haydee; Valdez Ramso, Maryzury; Jova Sed, Luis; De la Fuente, Andres

    1996-01-01

    The paper describes the menu, screens data files, programs and classifications of the systems, for keeping a record of their institutions, inspection and authorization, the personal register of incidents and accidents, and the national inventory of radiation protection sources and equipment. By making use of it, a comparison can be made of existing data of a practice with its requirements and a questionnaire of the inspection, (Checking list), the development and results of the inspection can be reported on, the program and notification of the inspection can be prepared and the information on the radiological situation- whether at a national or at a territorial level- can be evaluated

  8. Radiological diagnosis systems - problems and solutions

    International Nuclear Information System (INIS)

    Koeppe, P.

    1983-01-01

    An essential part of the work in a radiological diagnosis department is to produce the (written) physicians' reports. The majority is generally without any findings or ''normal pathologic'', only a minor part needs a special treatment. With respect to the quantity of this work, automation of the routine report writing was early attempted ley means of technical aids. Text processing systems and computers were used. The transition between these techniques is gradual. The article is limited to the use of computers in automation of report writing. (orig.) [de

  9. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Engesaeter, Ingvild Oevsteboe [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Haukeland University Hospital, The Norwegian Arthroplasty Register, Department of Orthopaedic Surgery, Bergen (Norway); Laborie, Lene Bjerke; Rosendahl, Karen [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Radiology, Bergen (Norway); Lehmann, Trude Gundersen; Fevang, Jonas; Engesaeter, Lars Birger [University of Bergen, Department of Surgical Sciences, Bergen (Norway); Haukeland University Hospital, Department of Orthopaedic Surgery, Bergen (Norway); Sera, Francesco [University College London Institute of Child Health, Medical Research Council Centre of Epidemiology for Child Health, London (United Kingdom); Pedersen, Douglas; Morcuende, Jose [University of Iowa Hospital and Clinics, Department of Orthopaedics and Rehabilitation, Iowa City, IA (United States); Lie, Stein Atle [Uni Health, Uni Research, Bergen (Norway)

    2012-07-15

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Toennis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good. (orig.)

  10. Radiological findings for hip dysplasia at skeletal maturity. Validation of digital and manual measurement techniques.

    Science.gov (United States)

    Engesæter, Ingvild Øvstebø; Laborie, Lene Bjerke; Lehmann, Trude Gundersen; Sera, Francesco; Fevang, Jonas; Pedersen, Douglas; Morcuende, José; Lie, Stein Atle; Engesæter, Lars Birger; Rosendahl, Karen

    2012-07-01

    To report on intra-observer, inter-observer, and inter-method reliability and agreement for radiological measurements used in the diagnosis of hip dysplasia at skeletal maturity, as obtained by a manual and a digital measurement technique. Pelvic radiographs from 95 participants (56 females) in a follow-up hip study of 18- to 19-year-old patients were included. Eleven radiological measurements relevant for hip dysplasia (Sharp's, Wiberg's, and Ogata's angles; acetabular roof angle of Tönnis; articulo-trochanteric distance; acetabular depth-width ratio; femoral head extrusion index; maximum teardrop width; and the joint space width in three different locations) were validated. Three observers measured the radiographs using both a digital measurement program and manually in AgfaWeb1000. Inter-method and inter- and intra-observer agreement were analyzed using the mean differences between the readings/readers, establishing the 95% limits of agreement. We also calculated the minimum detectable change and the intra-class correlation coefficient. Large variations among different radiological measurements were demonstrated. However, the variation was not related to the use of either the manual or digital measurement technique. For measurements with greater absolute values (Sharp's angle, femoral head extrusion index, and acetabular depth-width ratio) the inter- and intra-observer and inter-method agreements were better as compared to measurements with lower absolute values (acetabular roof angle, teardrop and joint space width). The inter- and intra-observer variation differs notably across different radiological measurements relevant for hip dysplasia at skeletal maturity, a fact that should be taken into account in clinical practice. The agreement between the manual and digital methods is good.

  11. Digital processing methodology applied to exploring of radiological images; Metodologia de processamento digital aplicada a exploracao de imagens radiologicas

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Cristiane de Queiroz

    2004-07-01

    In this work, digital image processing is applied as a automatic computational method, aimed for exploring of radiological images. It was developed an automatic routine, from the segmentation and post-processing techniques to the radiology images acquired from an arrangement, consisting of a X-ray tube, target and filter of molybdenum, of 0.4 mm and 0.03 mm, respectively, and CCD detector. The efficiency of the methodology developed is showed in this work, through a case study, where internal injuries in mangoes are automatically detected and monitored. This methodology is a possible tool to be introduced in the post-harvest process in packing houses. A dichotomic test was applied to evaluate a efficiency of the method. The results show a success of 87.7% to correct diagnosis and 12.3% to failures to correct diagnosis with a sensibility of 93% and specificity of 80%. (author)

  12. Image Format Conversion to DICOM and Lookup Table Conversion to Presentation Value of the Japanese Society of Radiological Technology (JSRT) Standard Digital Image Database.

    Science.gov (United States)

    Yanagita, Satoshi; Imahana, Masato; Suwa, Kazuaki; Sugimura, Hitomi; Nishiki, Masayuki

    2016-01-01

    Japanese Society of Radiological Technology (JSRT) standard digital image database contains many useful cases of chest X-ray images, and has been used in many state-of-the-art researches. However, the pixel values of all the images are simply digitized as relative density values by utilizing a scanned film digitizer. As a result, the pixel values are completely different from the standardized display system input value of digital imaging and communications in medicine (DICOM), called presentation value (P-value), which can maintain a visual consistency when observing images using different display luminance. Therefore, we converted all the images from JSRT standard digital image database to DICOM format followed by the conversion of the pixel values to P-value using an original program developed by ourselves. Consequently, JSRT standard digital image database has been modified so that the visual consistency of images is maintained among different luminance displays.

  13. Assessment of radiological protection systems among diagnostic radiology facilities in North East India.

    Science.gov (United States)

    Singh, Thokchom Dewan; Jayaraman, T; Arunkumar Sharma, B

    2017-03-01

    This study aims to assess the adequacy level of radiological protection systems available in the diagnostic radiology facilities located in three capital cities of North East (NE) India. It further attempts to understand, using a multi-disciplinary approach, how the safety codes/standards in diagnostic radiology framed by the Atomic Energy Regulatory Board (AERB) and the International Atomic Energy Agency (IAEA) to achieve adequate radiological protection in facilities, have been perceived, conceptualized, and applied accordingly in these facilities. About 30 diagnostic radiology facilities were randomly selected from three capitals of states in NE India; namely Imphal (Manipur), Shillong (Meghalaya) and Guwahati (Assam). A semi-structured questionnaire developed based on a multi-disciplinary approach was used for this study. It was observed that radiological practices undertaken in these facilities were not exactly in line with safety codes/standards in diagnostic radiology of the AERB and the IAEA. About 50% of the facilities had registered/licensed x-ray equipment with the AERB. More than 80% of the workers did not use radiation protective devices, although these devices were available in the facilities. About 85% of facilities had no institutional risk management system. About 70% of the facilities did not carry out periodic quality assurance testing of their x-ray equipment or surveys of radiation leakage around the x-ray room, and did not display radiation safety indicators in the x-ray rooms. Workers in these facilities exhibited low risk perception about the risks associated with these practices. The majority of diagnostic radiology facilities in NE India did not comply with the radiological safety codes/standards framed by the AERB and IAEA. The study found inadequate levels of radiological protection systems in the majority of facilities. This study suggests a need to establish firm measures that comply with the radiological safety codes/standards of the

  14. Evolution of the system of radiological protection

    International Nuclear Information System (INIS)

    2007-01-01

    The OECD Nuclear Energy Agency (NEA) has actively participated in discussions with the International Commission on Radiological Protection (ICRP) regarding the development of new recommendations that will replace those in ICRP Publication 60, which has long served as the international standard in this field. Part of this development process has involved the organisation of seven international workshops, including the First and Second Asian Regional Conferences on the Evolution of the System of Radiological Protection which took place in Tokyo, Japan in October 2002 and July 2004. The Third Asian Regional Conference was held on 5-6 July 2006, also in Tokyo. The main objective of these conferences was to ensure that the views and concerns of relevant Asian stakeholders, such as regulatory authorities, industry, professional societies and NGO, could be expressed and discussed with the ICRP. The three conferences provided the ICRP with specific views on how new recommendations could best be developed to address regulatory and implementation needs in the Asian context. These proceedings summarize the results and key discussions of the Third Asian Regional Conference. (author)

  15. Use of digital dosemeters for supporting staff radiation safety in paediatric interventional radiology suites.

    Science.gov (United States)

    McNeil, Sarah M; Lai, Priscilla; Connolly, Bairbre L; Gordon, Christopher L

    2013-12-01

    Modern-day interventional radiology (IR) procedures impart a wide range of occupational radiation doses to team members. Unlike thermoluminescent badges, digital dosemeters provide real-time dose readings, making them ideal for identifying different components during IR procedures, which influence staff radiation safety. This study focused solely on paediatric IR (PIR) cases. Digital dosemeters measured the impact of imaging modality, shielding, patient and operator specific factors, on the radiation dose received during various simulated and real live PIR procedures. They recorded potential dose reductions of 10- to 100-fold to each staff member with appropriate use of shielding, choice of imaging method, staff position in the room and complex interplay of other factors. The digital dosemeters were well tolerated by staff. Results highlight some unique radiation safety challenges in PIR that arise from dose increases with magnification use and close proximity of staff to the X-ray beam.

  16. Use of digital dosemeters for supporting staff radiation safety in paediatric interventional radiology suites

    International Nuclear Information System (INIS)

    McNeil, S. M.; Lai, P.; Connolly, B. L.; Gordon, C. L.

    2013-01-01

    Modern-day interventional radiology (IR) procedures impart a wide range of occupational radiation doses to team members. Unlike thermoluminescent badges, digital dosemeters provide real-time dose readings, making them ideal for identifying different components during IR procedures, which influence staff radiation safety. This study focused solely on paediatric IR (PIR) cases. Digital dosemeters measured the impact of imaging modality, shielding, patient and operator specific factors, on the radiation dose received during various simulated and real live PIR procedures. They recorded potential dose reductions of 10-to 100-fold to each staff member with appropriate use of shielding, choice of imaging method, staff position in the room and complex interplay of other factors. The digital dosemeters were well tolerated by staff. Results highlight some unique radiation safety challenges in PIR that arise from dose increases with magnification use and close proximity of staff to the X-ray beam. (authors)

  17. Implementation of a remote system for monitoring of radiological areas of radiological areas

    International Nuclear Information System (INIS)

    Velazquez E, Walter; Galuppo G, Emiliano; Gutierrez G, Jorge; Reyes R, Jerson

    2008-01-01

    Full text: Introduction: The present work shows the development of a radiation remote monitoring system which control radiological areas in the principal facilities at CCHEN and the development in the last years to use this system called SMARR (Remote Radiological Area Monitoring System). This is an important issue in radiological safety is to know 'on line' and in a 'continuously way' the radiological variables of areas, especially if in these areas people manage radioactive sources or material, the monitoring system are operative on La Reina and Lo Aguirre Nuclear Centers. This 'knowledge' gets a good support to the radiological safety to safeguard the environment and people in the facilities. Nuclear Chilean Commission: Actually, this system is daily operating to register the background radiation and level operation, for example of the facilities research reactor, cyclone, irradiators, in order to probe the behaviors under operational requirements. The system was made using common Geiger Muller and NaI detectors. This signal is received, data by data, for a collector computer which uses a Labview program to do this displayed on a screen computer using graphics to show the activity on a radiological area, and when the lectures pass a setting value automatically the system send by e-mail and text message which also can be received for cell phones enabled for this for the supervisor. Each monitored facility is completely independent of each other and store a data backup, also every installation are monitoring with server computer, it's concentrating the information and allow to view it on line in real time, trough the intranet and internet network. In addition, the information is stored in the special report in the server and available for to do a statistics and identify the operation periods, and control of radioactive sources. The Industry: The radiological protection on industry is necessary today, the typical instrumentation on the industry is growing up in the

  18. An advanced microcosting system for forecasting and managing radiology expenses

    International Nuclear Information System (INIS)

    Arenson, R.; Viale, R.; VanDerVoorde, F.

    1985-01-01

    The new prospective payment system encourages hospital cost containment and necessitates understanding actual cost for radiology procedures. The automated microcosting system described in this paper, utilizing data from the Radiology Information Management System, hospital expense reports, and payroll management reports, calculates an accurate unit cost for each procedure type. This data is very useful for cost control, enhancement of department efficiency, and planning

  19. Radiological contribution to skeletal changes in systemic mastocytosis - urticaria pigmentosa

    Energy Technology Data Exchange (ETDEWEB)

    Schratter, M.; Canigiani, G.; Schoenbauer, C.; Mach, K.

    1983-11-01

    Three patients are demonstrated suffering from systemic mastocytosis with skin and skeletal involvement. History, clinical and radiological results are reported. After a brief analysis of the pathogenetic mechanism, the radiological findings on the skeletal system in systemic mastocytosis are discussed. Finally, roentgenological differential diagnosis of the osseous lesions is explained.

  20. An Evolved System of Radiological Protection

    International Nuclear Information System (INIS)

    Kaneko, M.

    2004-01-01

    The current system of radiological protection based on the Linear No-Threshold (LNT) hypothesis has greatly contributed to the minimization of doses received by workers and members of the public. However, it has brought about r adiophobia a mong people and waste of resources due to over-regulation, because the LNT implies that radiation is harmful no matter how small the dose is. The author reviewed the results of research on health effects of radiation including major epidemiological studies on radiation workers and found no clear evidence of deleterious health effects from radiation exposures below the current maximum dose limits (50 mSv/y for workers and 5 mSv/y for members of the public), which have been adopted worldwide in the second half of the 20th century. Now that the existence of bio-defensive mechanisms such as DNA repair, apoptosis and adaptive response are well recognized, the linearity assumption cannot be said to be s cientific . Evidences increasingly imply that there are threshold effects in risk of radiation. A concept of practical thresholds or virtually safe doses will have to be introduced into the new system of radiological protection in order to resolve the low dose issues. Practical thresholds may be defined as dose levels below which induction of detectable radiogenic cancers or hereditary effects are not expected. If any workers and members of the public do not gain benefits from being exposed, excepting intentional irradiation for medical purposes, their radiation exposures should be kept below practical thresholds. On the assumption that the current dose limits are below practical thresholds and with no radiation detriments, there is no need of justification and optimization (ALARA) principles for occupational and public exposures. Then the ethical issue of justification to allow benefit to society to offset radiation detriments to individuals can be resolved. And also the ethical issue of optimization to exchange health or safety for

  1. Flat-screen detector systems in skeletal radiology

    International Nuclear Information System (INIS)

    Grampp, S.; Czerny, C.; Krestan, C.; Henk, C.; Heiner, L.; Imhof, H.

    2003-01-01

    Implementation of flat-panel detectors and digital integration of the technique instead of the use of conventional radiographs leads to a shortening of the work process. With flat-panel technology the image production process is shortened by more than 30%. Major advantages in the implementation of integrated RIS, PACS and flat-panel detector system are increases in quality because most mistakes in picture labeling can be avoided, easier handling without the need for cassettes, and the possibility of image post-processing. The diagnostic quality of the images in the field of musculoskeletal radiology is, in comparison to conventional radiographs, at least adequate and in most cases markedly improved with a marked reduction in radiation exposure of around 30-50%. With respect to the numerous advantages of the digital techniques and especially flat-panel technology there is a very high likelihood that conventional radiographs will be substituted in the coming years, even though the cost of the new technology is currently significantly higher compared to conventional systems. (orig.) [de

  2. Radiological protection national system. Basic security rules

    International Nuclear Information System (INIS)

    1981-01-01

    This work has been prepared as the first one of a set of standards and regulations that will be enforced to provide the protection of men and the environment against the undesirable effects of ionizing radiations. It establishes, in the first place, the system of dose limits for the country and the principles of its utilization. It takes into account the CIPR's recommendations in this area and the mentioned frame of reference, it establishes further the necessary restrictions for the application of the limits to the professionally exposed workers, as well as to the isolated members of the public and the population in general. In addition it establishes the general conditions to be met for the implementation of radiological protection, among them, the classification of working areas and working conditions as well as the compulsory periodical medical surveillance. (H.D.N.)

  3. BROADBAND DIGITAL GEOPHYSICAL TELEMETRY SYSTEM.

    Science.gov (United States)

    Seeley, Robert L.; Daniels, Jeffrey J.

    1984-01-01

    A system has been developed to simultaneously sample and transmit digital data from five remote geophysical data receiver stations to a control station that processes, displays, and stores the data. A microprocessor in each remote station receives commands from the control station over a single telemetry channel.

  4. A filmless radiology department in a full digital regional hospital: quantitative evaluation of the increased quality and efficiency.

    Science.gov (United States)

    Nitrosi, Andrea; Borasi, Giovanni; Nicoli, Franco; Modigliani, Gino; Botti, Andrea; Bertolini, Marco; Notari, Pietro

    2007-06-01

    Reggio Emilia hospital installed Picture Archiving and Communications Systems (PACS) as the final step towards a completely digital clinical environment completing the HIS/EMR and 1,400 web/terminals for patient information access. Financial benefits throughout the hospital were assessed upfront and measured periodically. Key indicators (radiology exam turnaround time, number of radiology procedures performed, inpatients length of stay before and after the PACS implementation, etc.) were analyzed and values were statistically tested to assess workflow and productivity improvements. The hospital went "filmless" in 28 weeks. Between the half of 2004 and the respective period in 2003, overall Radiology Department productivity increased by 12%, TAT improved by more than 60%. Timelier patient care resulted in decreased lengths of stay. Neurology alone experienced a 12% improvement in average patient stay. To quantify the impact of PACS on the average hospital stays and the expected productivity benefits to inpatient productivity were used a "high level" and a "detailed" business model. Annual financial upsides have exceeded $1.9 millions/year. A well-planned PACS deployment simplifies imaging workflow and improves patient care throughout the hospital while delivering substantial financial benefits. Staff buy-in was the key in this process and on-going training and process monitoring are a must.

  5. Digitalization of the radiological image. A new philosophy of the radiological imagery: the high resolution of the contrasts

    International Nuclear Information System (INIS)

    Schmidt, R.

    1983-01-01

    Three cases of digitalization are to be considered: static digitalization of the conventional radiographic image; static digitalization of the calculated image, like tomodensitometric images; dynamic digitalization of television images [fr

  6. A data management system for radiological data

    International Nuclear Information System (INIS)

    Burns, R.E.; Shonka, J.J.; DeBord, D.M.; Sukalac, T.R.

    1996-01-01

    A data management system oriented toward the visualization of large data sets has been developed. The system, which runs under the Windows trademark operating environment, provides most of the image-based algorithms developed by NASA for space-based imaging. When used in conjunction with large data sets, such as those acquired using position-sensing proportional counter based survey methods, the system can show images of survey data and subject those images to numerous mathematical transformations. The application of such mathematical treatments allows radiological survey data to be analyzed to an unprecedented extent. Visualization of survey data permits a user to see minor artifacts that would have been missed using only conventional survey techniques. The imaged survey data can be subjected to many different treatments, such as filters, smoothing, thresholding, color mapping, and statistical analyses. A variety of radioactive objects and areas have been surveyed using this system in conjunction with a novel floor monitor described elsewhere. Collection and examination of data in this fashion poses a new paradigm for assessing surface contamination. This research demonstrated that new methods for assessing survey performance are needed

  7. Radiology

    International Nuclear Information System (INIS)

    Sykora, A.

    2006-01-01

    In this text-book basic knowledge about radiology, biomedical diagnostic methods (radiography, computer tomography), nuclear medicine and safety and radiation protection of personnel on the radiodiagnostic place of work are presented

  8. Certification of digital system software

    International Nuclear Information System (INIS)

    Waclo, J.; Cook, B.; Adomaitis, D.

    1991-01-01

    The activities involved in the successful application of digital systems to Nuclear Protection functions is not achieved through happenstance. At Westinghouse there has been a longstanding program to utilize digital state of the art technology for protection system advancement. Thereby gaining the advantages of increased system reliability, performance, ease of operation and reduced maintenance costs. This paper describes the Westinghouse background and experience in the safety system software development process, including Verification and Validation, and its application to protection system qualification and the successful use for licensing the Eagle 21 Digital Process Protection System Upgrade. In addition, the lessons learned from this experience are discussed from the perspective of improving the development process through applying feedback of the measurements made on the process and the software product quality. The goal of this process optimization is to produce the highest possible software quality while recognizing the real world constraints of available resources, project schedule and the regulatory policies that are customary in the nuclear industry

  9. Implementation of a radiology information system in an University Hospital

    International Nuclear Information System (INIS)

    Marques, Paulo Mazzoncini de Azevedo; Santos, Antonio Carlos; Elias Junior, Jorge; Trad, Clovis Simao; Goes, Wilson Moraes; Castro, Carlos Roberto de

    2000-01-01

    This paper describes a radiology information system (RIS) developed and in the process of implementation in an University Hospital (Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto - Universidade de Sao Paulo) which integrates a plan for a 'filmless' radiology facility. (author)

  10. ORIGINAL ARTICLE Quality management systems in radiology

    African Journals Online (AJOL)

    few studies on quality management in radiology have been reported,[4] despite the need for ... organisational framework for the performance of QC tests, evaluation and institution of ... scores passed divided by the total 16 metrics considered.

  11. DIMOND II: Measures for optimising radiological information content and dose in digital imaging

    International Nuclear Information System (INIS)

    Dowling, A.; Malone, J.; Marsh, D.

    2001-01-01

    The European Commission concerted action on 'Digital Imaging: Measures for Optimising Radiological Information Content and Dose', DIMOND II, was conducted by 12 European partners over the period January 1997 to June 1999. The objective of the concerted action was to initiate a project in the area of digital medical imaging where practice was evolving without structured research in radiation protection, optimisation or justification. The main issues addressed were patient and staff dosimetry, image quality, quality criteria and technical issues. The scope included computed radiography (CR), image intensifier radiography and fluoroscopy, cardiology and interventional procedures. The concerted action was based on the consolidation of work conducted in the partner's institutions together with elective new work. Protocols and approaches to dosimetry, radiological information content/image quality measurement and quality criteria were established and presented at an international workshop held in Dublin in June 1999. Details of the work conducted during the DIMOND II concerted action and a summary of the main findings and conclusions are presented in this contribution. (author)

  12. Quality Assurance System in dental radiology

    International Nuclear Information System (INIS)

    Yacobenco, A.; Tauhata, L.; Infantosi, A.F.

    1998-01-01

    According to data published by the National Commission of Nuclear Energy (CNEN) it was observed that in Dental Radiology more than 80% of the exams reveal entrance skin doses higher than 5,0 mGy, that proximately 85% of the dentists sub-develop the films and 40% of the equipment have low performance regarding collimation, filtration and other problems. This is a critical situation for the population regarding life quality and requires prompt attention from the sanitary authority. Face and universe of 30,000 dentist in the state of Sao Paulo, it was necessary to organize a technical and administrative structure to establish procedures, elaborate training course and create an adequate software system to control all the inspections. The inspection control was based on monitoring the geometrical and exposure parameters as well as the implementation of internal procedures. It was also implemented a control of reject rate and a routine check of the control books. Results show a great improvement of the parameters in 152 of the x ray tubes considered here. Entrance skin dose up to 2,5 mGy increased from 19% to 57%, field size up to 6 cm, increased from 33 % to 96%, k Vp exactitude (13%) and exposure time (67%) jumped to 100%. Also 100% were attained with regards to filtration, collimation and several internal procedures. By the results showed above, we can conclude that we are in the right direction and that all goals will be reached

  13. Computer-assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.

    1988-01-01

    New digital imaging modalities and more sophisticated image processing systems will have a profound effect on those areas of medicine concerned with imaging. This mainly means computer-assisted radiology (CAR) and implies a transition from analog film systems to digital imaging systems, integration of digital imaging modalities through picture archiving and communication systems (PACS) and the graduated employment of image-oriented medical work stations (MWS) for computer-assisted representation, communication, diagnosis, and therapy planning. (orig.) [de

  14. Radiology

    International Nuclear Information System (INIS)

    Meyers, M.A.

    1989-01-01

    This paper reports on disease processes originating within the alimentary tract, may extend through the extraperitoneal spaces, and abnormalities primarily arising within other extraperitoneal sites may significantly affect the bowel. Symptoms and signs may be obscure, delayed, or nonspecific, and the area is generally not accessible to auscultation, palpation, or percussion. Radiologic evaluation thus plays a critical role

  15. Digital remote viewing system for coronary care unit

    International Nuclear Information System (INIS)

    Cho, P.S.; Tillisch, J.; Huang, H.K.

    1987-01-01

    A digital remote viewing system developed for the coronary care unit at the UCLA Medical Center has been in clinical operation since March 1, 1987. The present system consists of three 512-line monitors, VAX 11/750, Gould IP8500 image processor and a broad-band communication system. The patients' images are acquired with a computed radiography system and are transmitted to the coronary care unit, which is five floors above the radiology department. This exhibit presents the architecture and the performance characteristics of the system. Also, the second-generation system, which consists of an intelligent local work station with three 1,024-line monitors and a fast digital communication network, will be introduced

  16. Development of DIGITEXαPlus digital angiographic system

    International Nuclear Information System (INIS)

    Imanishi, Tetsuo; Miura, Yusuke; Sasaki, Osamu; Furuyama, Makoto; Yasumi, Masayuki

    2001-01-01

    The functions required of digital angiographic (DA) systems have been noticeably changing with the recent popularization of the technique of interventional radiology (IVR) in the field of angiography. We have developed a new digital angiographic system, named the DIGITEXαPlus, which is designed to meet the requirements of the latest IVR technologies. The DIGITEXαPlus system is equipped with a high-performance one-million-pixel CCD camera, a newly developed F.P.O. (fluoro-power optimizer), and a contrast-priority radiography control system, which combine together to provide high quality of images both in fluoroscopy and in fluorography. In this new system, a low-dose pulsed fluoroscopy method, employed as standard, minimizes the X-ray doses to patients, and an image controller (IVR MASTER) of a joy stick type provides more diversified functions that its predecessors. These two features enhance the reliability, and simplifies the operation, of the IVR system as a whole. (author)

  17. Quality management systems in radiology. Implementation in hospital and radiology practice

    International Nuclear Information System (INIS)

    Teichgraeber, U.; Bucourt, M. de

    2010-01-01

    The concept of quality and the principle of continuous quality improvement are implemented by quality management systems. Quality management systems surpass mere quality control. These systems account for patient and employee needs, the management style and the structure of an enterprise. Many of these quality management systems are used in the health care industry. Some of these systems and their form of application in radiology are introduced here. (orig.)

  18. National inquiry system of radiological events: a viable proposal

    International Nuclear Information System (INIS)

    Xavier, Ana Maria; Cavalcante, Vera Lucia.

    1996-01-01

    The SINAER- National Inquiry System of Radiological Events is a supportive structure devised to deal with the request of help or complaints that involve sources of ionizing radiations in the national territory

  19. Public financing systems for radiology: experience in 12 European countries

    International Nuclear Information System (INIS)

    Kesteloot, K.

    1999-01-01

    This paper illustrates the evolution in public health care financing systems in 12 European countries, in terms of the financing of radiology services. The financing systems for radiology used by public health care financing agencies are described in detail. The implications of these new financing conditions for health care delivery are briefly sketched. The paper concludes with some strategies to help radiologists cope with the tightening financing conditions for medical imaging. (orig.) (orig.)

  20. Radiological Information Management System - an effective tool for radiological information dissemination and dose control

    International Nuclear Information System (INIS)

    Sharma, Ravikant; Singh, Mintoo; Abhishek, Neel; Yadav, Umed

    2012-01-01

    Information is a key element for success of an organization, and timely information is a guarantee to success. To meet this essential requirement, Health Physics Unit at RAPS-5 and 6 has conceived, designed and implemented a comprehensive integrated network based system, named Radiological Information Management System (RIMS). The complete system is designed on the principle of FOUR ONE's i.e. ONE data entry by ONE individual at ONE time using ONE system/client

  1. Characteristics of dual-gate thin-film transistors for applications in digital radiology

    International Nuclear Information System (INIS)

    Waechter, D.; Huang, Z.; Zhao, W.; Blevis, I.; Rowlands, J.A.

    1996-01-01

    A large-area flat-panel detector for digital radiology is being developed. The detector uses an array of dual-gate thin-film transistors (TFTs) to read out X-ray-generated charge produced in an amorphous selenium (a-Se) layer. The TFTs use CdSe as the semiconductor and use the bottom gate for row selection. The top gate can be divided into a 'deliberate' gate, covering most of the channel length, and small 'parasitic' gates that consist of: overlap of source or drain metal over the top-gate oxide; and gap regions in the metal that are covered only by the a-Se. In this paper we present the properties of dual-gate TFTs and examine the effect of both the deliberate and parasitic gates on the detector operation. Various options for controlling the top-gate potential are analyzed and discussed. (author)

  2. Value of digital radiology in the diagnosis of affections causing dysphagia

    International Nuclear Information System (INIS)

    Rodriguez Allende, Miguel A.

    2004-01-01

    A prospective work was done to stress the value of digital radiology in the diagnosis of affections causing dysphagia. 168 patients that were applied this technique were screened and the results were compared with those obtained by using the conventional technique. It was observed that the results of the double contrast study in the diagnosis of affections of the small intestine were positive in 89.5 % and negative in 10.5 %. In all cases, the diagnosis was confirmed by other techniques.The following results were attained: sensitivity - 100 %, specificity - 97 % and positive predictive values - 98.7 %. The advantages and characteristics of the technique were exposed and a description of it was made

  3. Image Gently: Challenges for radiologic technologists when performing digital radiography in children

    International Nuclear Information System (INIS)

    Goske, Marilyn J.; Smith, Susan N.; Charkot, Ellen; Herrmann, Tracy; John, Susan D.; Mills, Thalia T.; Morrison, Gregory

    2011-01-01

    The development of digital radiography (DR) has provided numerous benefits for pediatric imaging, including the ability to post-process images and to make images immediately available for access by care providers. However, DR presents several significant challenges for the radiologic technologists who are responsible for operating the equipment and producing high-quality images in children. This paper discusses those challenges, including lack of standardization among vendors, particularly with regard to the exposure indicator; lack of pediatric-specific educational materials and pediatric techniques; the need for manual technique instead of the use of automatic exposure control in smaller children; and complications related to field size, collimation and shielding in small children. Specific actions and design modifications that might facilitate the effective management of these challenges will be also described. The implementation of measures to promote the production of optimal images while minimizing radiation exposure requires cooperation and communication among imaging professionals, manufacturers and regulatory agencies. (orig.)

  4. Numerical analysis of edge effects in side illuminated strip detectors for digital radiology

    CERN Document Server

    Krizaj, D

    2000-01-01

    The influence of edge defects on side illuminated X-ray strip detectors for digital radiology is investigated by numerical device modeling. By assuming positive fixed oxide charges on side and top surfaces simulations have shown strong curvature of the equipotential lines in the edge region. A fraction of the edge generated current surpasses the edge guard-ring junction and is collected by the readout strips. As a consequence, strips cannot be placed close to the edge of the structure and collection efficiency is reduced. An n-on-n instead of a p-on-n strip detector is proposed enabling collection of edge generated carriers by a very narrow guard-ring junction and placement of the readout strip close to the edge without increase of the strip leakage current.

  5. Radiological evaluation of swallowing and clinical patterns of systemic sclerosis

    International Nuclear Information System (INIS)

    Montesi, A.; Pesaresi, A.; Cavalli, M.L.; Serri, L.; Salmistraro, D.; Candela, M.; Gabrielli, A.

    1990-01-01

    Fifty-one patients with systemic sclerosis (scleroderma) were studied by means of videofluoroscopy in order to evaluate the abnormalities in the oral-pharyngeal and esophageal phases of deglutition and to correlate the radiological patterns with the clinical features of the disease. Thirteen patients (25.5%) exhibited swallowing disorders such as oral leakage, retention, penetration, mild or moderate aspiration and abnormal upper esophageal sphincter behavior. These dysfunctions were more evident in patients with esophageal motility abnormalities. A normal radiological pattern in the esophagus was not associated with swallowing alterations. Remarkably, patients with oral-pharyngeal disorders had a higher incidence of lung diseases. Forty-five patients (88%) exhibited disorders of the esophageal phase of deglutition, such as mild or severe motility abnormalities or hiatal hernia, gastro-esophageal reflux, reflux esophagitis, and stricture. Radiological findings in the esophagus can be abnormal in the early stages of the disease. On the other hand, the radiological pattern of esophageal motility can be occasionally negative in advanced or extensive disease. This indicates a discrepancy between clinical symptoms and radiological picture of the esophagus. The radiological examination of the oral-pharyngeal and esophageal phases of deglutition is important in patients with scleroderma in order to evaluate visceral involvement, motility disorders, and risk of aspiration. Such radiological information can be useful in preventing esophagitis and pulmonary complications

  6. Collaborative Branding of Partnered Health Systems in Radiology.

    Science.gov (United States)

    Kalambo, Megan; Parikh, Jay R

    2018-01-01

    In an effort to expand clinical reach and achieve economies of scale, academic radiology practices are strategically expanding into the community by establishing partnerships with existing community health systems. A challenge with this model is to effectively brand the collaboration in a way that underscores the strengths of both partners. In this article, the authors look at the benefits and risks of cobranding and review cobranding strategies for implementation by academic radiology practices considering partnership-based network expansion. Published by Elsevier Inc.

  7. Portable digital electronic radiography system

    International Nuclear Information System (INIS)

    Sawicka, B.D.

    1995-01-01

    Radiography is a standard nondestructive technique in the industrial testing of materials and components. It is routinely used during the construction, maintenance and repair of nuclear plants. Traditionally, radiography is performed using photographic film (film radiography, FR). Recent developments in solid-state area imaging radiation detectors, miniature electronics and computer software/hardware techniques have brought electronic alternatives to FR. In recent years various electronic radiography (ER) techniques have served as alternatives to FR, these proved beneficial in some applications. While originally developed to provide real time imaging, ER may offer other advantages over FR, depending on the application. Work was undertaken at CRL to review progress in ER techniques and evaluate the possibility of constructing a portable DER (digital electronic radiography) system, for the inspection of power plant components. A suitable DER technique has been developed and a proof of principle portable system constructed. As this paper demonstrates, a properly designed ER system can be small and compact, while providing radiographic examination with acceptable image quality and the benefits of ER imaging. The CRL DER system can operate with radioactive sources typical of FR. While it does not replace FR, our DER system is expected to be beneficial in specific applications for Candu maintenance, reducing cost, labour and time. Practical, cost saving applications of this system are expected to include valve monitoring and foreign object location during maintenance at Candu reactors

  8. Performances of different digital mammography imaging systems: Evaluation and comparison

    Energy Technology Data Exchange (ETDEWEB)

    Bisogni, M.G. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy)]. E-mail: giuseppina.bisogni@pi.infn.it; Bulajic, D. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); International Centre for Theoretical Physics, Trieste (Italy); Delogu, P. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Fantacci, M.E. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Novelli, M. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Quattrocchi, M. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Rosso, V. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy); Stefanini, A. [Dipartimento di Fisica ' E. Fermi' , Universita di Pisa, e Sezione INFN di Pisa, Pisa (Italy)

    2005-07-01

    Digital mammography is entering routine clinical use and many commercial systems are now in use in the radiological units for screening and diagnostic mammography. At the same time, the research in the digital mammography field is very active in the development of more and more performing devices. In this paper we present the performance of single photon counting pixel detectors (MedipixI) tailored for digital mammographic applications. These devices are based on semiconductor (Si and GaAs) pixel detectors of different thickness, read-out by custom designed integrated circuits. To assess the imaging capability of such systems, the images of a mammographic phantom have been acquired in standard conditions for a clinical examination. The signal-to-noise ratio (SNR) of details simulating tumor masses has been evaluated. The same phantom has been also radiographed by three different commercial digital mammographic systems in the same reference conditions and a comparison in terms of SNR has been carried out. The spatial resolution of the single photon counting systems has also been evaluated by measuring the line spread function with the edge technique and then calculating the Modulation Transfer Function (MTF). The MTFs of the single photon counting systems have been compared with the MTFs of the commercial systems.

  9. Performances of different digital mammography imaging systems: Evaluation and comparison

    International Nuclear Information System (INIS)

    Bisogni, M.G.; Bulajic, D.; Delogu, P.; Fantacci, M.E.; Novelli, M.; Quattrocchi, M.; Rosso, V.; Stefanini, A.

    2005-01-01

    Digital mammography is entering routine clinical use and many commercial systems are now in use in the radiological units for screening and diagnostic mammography. At the same time, the research in the digital mammography field is very active in the development of more and more performing devices. In this paper we present the performance of single photon counting pixel detectors (MedipixI) tailored for digital mammographic applications. These devices are based on semiconductor (Si and GaAs) pixel detectors of different thickness, read-out by custom designed integrated circuits. To assess the imaging capability of such systems, the images of a mammographic phantom have been acquired in standard conditions for a clinical examination. The signal-to-noise ratio (SNR) of details simulating tumor masses has been evaluated. The same phantom has been also radiographed by three different commercial digital mammographic systems in the same reference conditions and a comparison in terms of SNR has been carried out. The spatial resolution of the single photon counting systems has also been evaluated by measuring the line spread function with the edge technique and then calculating the Modulation Transfer Function (MTF). The MTFs of the single photon counting systems have been compared with the MTFs of the commercial systems

  10. Radiological reporting system developed with FileMakerPro. Cooperation with HIS, RIS, and PACS

    International Nuclear Information System (INIS)

    Kawakami, Satoshi

    2004-01-01

    This article briefly describes our original radiological reporting system. This system was developed with the widely used database software FileMakerPro (ver 5.5). The reporting system can obtain information about patients and examinations from a radiology information system (RIS) by the Open DataBase Connectivity (ODBC) technique. By clicking the button on the reporting system, the corresponding Digital Imaging and Communications in Medicine (DICOM) images can be displayed on a picture archiving and communication system (PACS) workstation monitor. Reference images in JPEG format can be easily moved from PACS to the reporting system. Reports produced by the reporting system are distributed to the hospital information system (HIS) in Portable Document Format (PDF), through another web server. By utilizing the capacity of FileMakerPro, the human-machine interface of the system has been able to be improved easily. In addition, cooperation with HIS, RIS, and PACS could be constructed. Therefore, this original system would contribute to increasing the efficiency of radiological diagnosis. (author)

  11. Design principles for radiological protection instrumentation systems

    International Nuclear Information System (INIS)

    Wells, F.H.; Powell, R.G.

    1981-02-01

    This Code of Practice takes the form of recommendations intended for designers and installers of Radiological Protection Instrumentation, and should also be of value to the newcomer to the R.P.I. field. Topics are discussed under the following headings: outline of R.P.I. requirements, specifying the requirement, satisfying the requirements, (overall design, availability and reliability, information display, human factors, power supplies, manufacture, quality assurance, testing, and cost analysis), supply, location and operation of the equipment, importance of documentation. (U.K.)

  12. Worldwide Implementation of Digital Imaging in Radiology. A Resource Guide. In Cooperation with the World Health Organization

    International Nuclear Information System (INIS)

    2015-01-01

    This publication provides a basic introduction to digital technology and digital networks as well as an overview of the issues to consider when implementing such technology in diagnostic radiology. In an area that is under rapid development, it provides a careful analysis of the principles and advice on implementation and sustainability of digital imaging and teleradiology. The transition from film to digitally based medical imaging is complex and requires knowledge and planning to be successful. This comprehensive resource guide contains information on the needs and implications of a transition to digital imaging with case studies for different facilities requiring different levels of communication connectivity. It is aimed at hospital administrators and managers, radiologists and radiographers/technologists, medical physicists and clinical engineers as well as information technology staff

  13. Radiology

    International Nuclear Information System (INIS)

    Lissner, J.

    1985-01-01

    Diagnostic radiology is still the foremost of all innovative medical disciplines. This has many advantages but also some handicaps, e.g. the siting problem of medical equipment whose clinical potential is not fully known. This applies in particular to nuclear spin tomography, where the Laender governments and the Scientific Council seen to agree that all universities should have the appropriate equipment as soon as possible in order to intensify interdisciplinary research. Formerly, in the case of computerized tomography, there was less readiness. As a result, the siting of CT equipment is less organically structured. A special handicap of innovative fields is the problem of training and advanced training. The Chamber of Medicine and the Association of Doctors Participating in the Health Insurance Plan have issued regulations aimed at a better standardisation in this field. (orig.) [de

  14. Speech recognition implementation in radiology

    International Nuclear Information System (INIS)

    White, Keith S.

    2005-01-01

    Continuous speech recognition (SR) is an emerging technology that allows direct digital transcription of dictated radiology reports. The SR systems are being widely deployed in the radiology community. This is a review of technical and practical issues that should be considered when implementing an SR system. (orig.)

  15. Teaching syllabus for radiological aspects of breast cancer screening with digital mammography

    International Nuclear Information System (INIS)

    Van Ongeval, C.; Van Steen, A.; Bosmans, H.

    2008-01-01

    The purpose of this study is to discuss the content of our new accreditation programme for radiologists' reading digital mammograms in a screening setting and to report our first experience with the new course. The course consisted of a theoretical part, given by the medical physicist, and a practical part given by the radiologist. The practical session is closely linked with the theoretical part and a reading session. The material is fully digital and can be presented on different platforms. In practice, the need for parallel soft-copy reading sessions on high-end workstations limits the number of participants. A high level of interactivity was noted between teacher and participant, with a thorough discussion of different digital mammography systems during a single teaching course. The main challenge for the teacher turned out to be the collection of representative material and the continuous updating of the material: new systems, processing techniques and artefacts need to be included regularly. (authors)

  16. Human engineering of a radiological diagnostic system

    International Nuclear Information System (INIS)

    Andou, Eiji; Yuba, Fumimaro; Kotoh, Yukitoshi; Oohara, Kazuo; Uto, Fumiaki.

    1992-01-01

    Current practices for patient safety control in radiological diagnosis may involve problems. For solving of these problems, we have to bear in mind that the mental and physical capacity of patients tend to be limited during radiological testing. When radiography is performed using a general X-ray device at a source table distance (STD) of 100 cm, the patient's head can touch the X-ray tube housing during position adjustment on the stand (up and down adjustment) or the patient is made to take an unnatural posture during body positioning. With this in mind, we carried out a questionnaire survey about source image receptor distance (SID). This survey disclosed that more than 92% of the institutions have adapted 100 cm STD. We then conducted a three-dimensional analysis of a patient's posture and motion by video taping patients during positioning on a roentgenographic table. This analysis revealed that the adoption of the 120 cm STD resulted in less contact between the patient's head and X-ray tube housing, less of unnatural body position and less time required for positioning adjustment when compared to those at 100 cm STD. These results indicate that the current STD (100 cm) is not suitable for safe and smooth adjustment of the positioning of a patient's body of a roentgenographic table. We examined the optimun STD, taking into consideration the dimensions of patient's movement and posture during an X-ray examination. (author)

  17. Radiology information system: a workflow-based approach

    International Nuclear Information System (INIS)

    Zhang, Jinyan; Lu, Xudong; Nie, Hongchao; Huang, Zhengxing; Aalst, W.M.P. van der

    2009-01-01

    Introducing workflow management technology in healthcare seems to be prospective in dealing with the problem that the current healthcare Information Systems cannot provide sufficient support for the process management, although several challenges still exist. The purpose of this paper is to study the method of developing workflow-based information system in radiology department as a use case. First, a workflow model of typical radiology process was established. Second, based on the model, the system could be designed and implemented as a group of loosely coupled components. Each component corresponded to one task in the process and could be assembled by the workflow management system. The legacy systems could be taken as special components, which also corresponded to the tasks and were integrated through transferring non-work- flow-aware interfaces to the standard ones. Finally, a workflow dashboard was designed and implemented to provide an integral view of radiology processes. The workflow-based Radiology Information System was deployed in the radiology department of Zhejiang Chinese Medicine Hospital in China. The results showed that it could be adjusted flexibly in response to the needs of changing process, and enhance the process management in the department. It can also provide a more workflow-aware integration method, comparing with other methods such as IHE-based ones. The workflow-based approach is a new method of developing radiology information system with more flexibility, more functionalities of process management and more workflow-aware integration. The work of this paper is an initial endeavor for introducing workflow management technology in healthcare. (orig.)

  18. Superconductor Digital-RF Receiver Systems

    Science.gov (United States)

    Mukhanov, Oleg A.; Kirichenko, Dmitri; Vernik, Igor V.; Filippov, Timur V.; Kirichenko, Alexander; Webber, Robert; Dotsenko, Vladimir; Talalaevskii, Andrei; Tang, Jia Cao; Sahu, Anubhav; Shevchenko, Pavel; Miller, Robert; Kaplan, Steven B.; Sarwana, Saad; Gupta, Deepnarayan

    Digital superconductor electronics has been experiencing rapid maturation with the emergence of smaller-scale, lower-cost communications applications which became the major technology drivers. These applications are primarily in the area of wireless communications, radar, and surveillance as well as in imaging and sensor systems. In these areas, the fundamental advantages of superconductivity translate into system benefits through novel Digital-RF architectures with direct digitization of wide band, high frequency radio frequency (RF) signals. At the same time the availability of relatively small 4K cryocoolers has lowered the foremost market barrier for cryogenically-cooled digital electronic systems. Recently, we have achieved a major breakthrough in the development, demonstration, and successful delivery of the cryocooled superconductor digital-RF receivers directly digitizing signals in a broad range from kilohertz to gigahertz. These essentially hybrid-technology systems combine a variety of superconductor and semiconductor technologies packaged with two-stage commercial cryocoolers: cryogenic Nb mixed-signal and digital circuits based on Rapid Single Flux Quantum (RSFQ) technology, room-temperature amplifiers, FPGA processing and control circuitry. The demonstrated cryocooled digital-RF systems are the world's first and fastest directly digitizing receivers operating with live satellite signals in X-band and performing signal acquisition in HF to L-band at ˜30GHz clock frequencies.

  19. Workflow improvement and efficiency gain with near digitalization of a Radiology Department; Workflowverbesserung und Effizienzsteigerungsaspekte durch nahezu vollstaendige Digitalisierung einer Roentgenabteilung

    Energy Technology Data Exchange (ETDEWEB)

    Langen, H.L.; Bielmeier, J.; Selbach, R. [Missionsaerztlichen Klinik Wuerzburg (Germany). Radiologische Abteilung; Wittenberg, G. [Univ. Wuerzburg (Germany). Inst. fuer Roentgendiagnostik; Feustel, H. [Missionsaerztlichen Klinik Wuerzburg (Germany). Chirurgische Abteilung

    2003-10-01

    Purpose: To determine the temporal changes of the workflow caused by digitalization of the radiology department after installation of digital luminescence-radiography (DLR), a radiology information system (RIS) and picture archiving and communication system (PACS) at the Missionsaerztliche Klinik in April 2000. Materials and methods: In a comparative study, a workflow analysis by manual registration of different work steps was performed before (1999) and after (2001) digitalization of a radiology department. Results: The digitalization shortened the examination time for patients from a mean of 8 min to 5 min. The time the patient is absent from the emergency room did not change. Reporting radiographic examinations including comparison with previous studies begins earlier from a mean of 2 h 37 min to 17 min. Using PACS, 85.9% of all cases could be interpreted on the day of the examination (without PACS 41.2%) and 87.2% of the reports were completed the day after the examination (without PACS 64.5%). No time differences were found between reading conventional studies on the monitor or as soft-copy. Conclusion: Compared to conventional film-screen systems, complete digitalization of a radiology department is time saving at nearly all steps of the workflow, with expected positive effects on the workflow quality of the entire hospital. (orig.) [German] Fragestellung/Zielsetzung: An der Missionsaerztlichen Klinik folgte im April 2000 mit der Einfuehrung der digitalen Lumineszenzradiographie (DLR), eines radiologischen Informationssystems (RIS) und eines Bildarchivierungs- und Kommunkationssystems (PACS) die vollstaendige Digitalisierung der Roentgenabteilung. Die durch diese Umstellung bedingten zeitlichen Veraenderungen der Prozessablaeufe in der Roentgenabteilung wurden untersucht. Material und Methode: In Form einer Vorher-Nachher-Studie wurde 1999 im konventionellen und 2001 im digitalen Routinebetrieb anhand von Analysen der Prozessablaeufe eine manuelle

  20. Digital systems from logic gates to processors

    CERN Document Server

    Deschamps, Jean-Pierre; Terés, Lluís

    2017-01-01

    This textbook for a one-semester course in Digital Systems Design describes the basic methods used to develop “traditional” Digital Systems, based on the use of logic gates and flip flops, as well as more advanced techniques that enable the design of very large circuits, based on Hardware Description Languages and Synthesis tools. It was originally designed to accompany a MOOC (Massive Open Online Course) created at the Autonomous University of Barcelona (UAB), currently available on the Coursera platform. Readers will learn what a digital system is and how it can be developed, preparing them for steps toward other technical disciplines, such as Computer Architecture, Robotics, Bionics, Avionics and others. In particular, students will learn to design digital systems of medium complexity, describe digital systems using high level hardware description languages, and understand the operation of computers at their most basic level. All concepts introduced are reinforced by plentiful illustrations, examples, ...

  1. Digital control system of advanced reactor

    International Nuclear Information System (INIS)

    Peng Huaqing; Zhang Rui; Liu Lixin

    2001-01-01

    This article produced the Digital Control System For Advanced Reactor made by NPIC. This system uses Siemens SIMATIC PCS 7 process control system and includes five control system: reactor power control system, pressurizer level control system, pressurizer pressure control system, steam generator water level control system and dump control system. This system uses three automatic station to realize the function of five control system. Because the safety requisition of reactor is very strict, the system is redundant. The system configuration uses CFC and SCL. the human-machine interface is configured by Wincc. Finally the system passed the test of simulation by using RETRAN 02 to simulate the control object. The research solved the key technology of digital control system of reactor and will be very helpful for the nationalization of digital reactor control system

  2. Developing standard transmission system for radiology reporting including key images

    International Nuclear Information System (INIS)

    Kim, Seon Chil

    2007-01-01

    Development of hospital information system and Picture Archiving Communication System is not new in the medical field, and the development of internet and information technology are also universal. In the course of such development, however, it is hard to share medical information without a refined standard format. Especially in the department of radiology, the role of PACS has become very important in interchanging information with other disparate hospital information systems. A specific system needs to be developed that radiological reports are archived into a database efficiently. This includes sharing of medical images. A model is suggested in this study in which an internal system is developed where radiologists store necessary images and transmit them is the standard international clinical format, Clinical Document Architecture, and share the information with hospitals. CDA document generator was made to generate a new file format and separate the existing storage system from the new system. This was to ensure the access to required data in XML documents. The model presented in this study added a process where crucial images in reading are inserted in the CDA radiological report generator. Therefore, this study suggests a storage and transmission model for CDA documents, which is different from the existing DICOM SR. Radiological reports could be better shared, when the application function for inserting images and the analysis of standard clinical terms are completed

  3. Cognitive and system factors contributing to diagnostic errors in radiology.

    Science.gov (United States)

    Lee, Cindy S; Nagy, Paul G; Weaver, Sallie J; Newman-Toker, David E

    2013-09-01

    In this article, we describe some of the cognitive and system-based sources of detection and interpretation errors in diagnostic radiology and discuss potential approaches to help reduce misdiagnoses. Every radiologist worries about missing a diagnosis or giving a false-positive reading. The retrospective error rate among radiologic examinations is approximately 30%, with real-time errors in daily radiology practice averaging 3-5%. Nearly 75% of all medical malpractice claims against radiologists are related to diagnostic errors. As medical reimbursement trends downward, radiologists attempt to compensate by undertaking additional responsibilities to increase productivity. The increased workload, rising quality expectations, cognitive biases, and poor system factors all contribute to diagnostic errors in radiology. Diagnostic errors are underrecognized and underappreciated in radiology practice. This is due to the inability to obtain reliable national estimates of the impact, the difficulty in evaluating effectiveness of potential interventions, and the poor response to systemwide solutions. Most of our clinical work is executed through type 1 processes to minimize cost, anxiety, and delay; however, type 1 processes are also vulnerable to errors. Instead of trying to completely eliminate cognitive shortcuts that serve us well most of the time, becoming aware of common biases and using metacognitive strategies to mitigate the effects have the potential to create sustainable improvement in diagnostic errors.

  4. Conception and data transfer analysis of an open-source digital image archive designed for radiology

    International Nuclear Information System (INIS)

    Teichgraeber, U.K.M.; Lehmkuhl, L.; Harderer, A.; Emmel, D.; Ehrenstein, T.; Ricke, J.; Felix, R.

    2003-01-01

    Purpose: Implementation of a self-designed, web-based digital image archive incorporating the existing DICOM infrastructure to assure distribution of digital pictures and reports and to optimize work flow. Assessment after three years. Materials and methods: Open-source software was used to guarantee highest reliability and cost effectiveness. In view of rapidly increasing capacity and decreasing costs of hard discs (HDs), HDs were preferred over slower and expensive magneto-optical disk (MOD) or tape storage systems. The number of installed servers increased from one to 12. By installing HDs with increased capacities, the number of servers should be kept constant. Entry and access of data were analyzed over two 4-month periods (after 1.5 and 2 years of continuous operations). Results: Our digital image archive was found to be very reliable, cost effective and suitable for its designated tasks. As judged from the measured access volume, the average utilization of the system increased by 160%. In the period from January to April 2002, the users accessed 239.8 gigabyte of the stored 873.7 gigabyte image data (27%). The volume of the stored data added 20%, mainly due to an increase in cross-section imaging. Conclusion: The challenge of developing a digital image archive with limited financial resources resulted in a practicable and expandable solution. The utilization, number of active users and volume of transferred data have increased significantly. Our concept of utilizing HDs for image storage proved to be successful. (orig.) [de

  5. Socioeconomic trends in radiology

    International Nuclear Information System (INIS)

    Barneveld Binkhuysen, F.H.

    1998-01-01

    For radiology the socioeconomic environment is a topic of increasing importance. In addition to the well-known important scientific developments in radiology such as interventional MRI, several other major trends can be recognized: (1) changes in the delivery of health care, in which all kinds of managed care are developing and will influence the practice of radiology, and (2) the process of computerization and digitization. The socioeconomic environment of radiology will be transformed by the developments in managed care, teleradiology and the integration of information systems. If radiologists want to manage future radiology departments they must have an understanding of the changes in the fields of economics and politics that are taking place and that will increasingly influence radiology. Some important and recognizable aspects of these changes will be described here. (orig.)

  6. Optimization Of Scan Range For 3d Point Localization In Statscan Digital Medical Radiology

    Directory of Open Access Journals (Sweden)

    Jacinta S. Kimuyu

    2015-08-01

    Full Text Available The emergence of computerized medical imaging in early 1970s which merged with digital technology in the 1980s was celebrated as a major breakthrough in three-dimensional 3D medicine. However a recent South African innovation the high speed scanning Lodox Statscan Critical Digital Radiology modality posed challenges in X-ray photogrammetry due to the systems intricate imaging geometry. The study explored the suitability of the Direct Linear Transformation as a method for the determination of 3D coordinates of targeted points from multiple images acquired with the Statscan X-ray system and optimization of the scan range. This investigation was carried out as a first step towards the development of a method to determine the accurate positions of points on or inside the human body. The major causes of errors in three-dimensional point localization using Statscan images were firstly the X-ray beam divergence and secondly the position of the point targets above the X-ray platform. The experiments carried out with two reference frames showed that point positions could be established with RMS values in the mm range in the middle axis of the X-ray patient platform. This range of acceptable mm accuracies extends about 15 to 20 cm sideways towards the edge of the X-ray table and to about 20 cm above the table surface. Beyond this range accuracy deteriorated significantly reaching RMS values of 30mm to 40 mm. The experiments further showed that the inclusion of control points close to the table edges and more than 20 cm above the table resulted in lower accuracies for the L - parameters of the DLT solution than those derived from points close to the center axis only. As the accuracy of the L - parameters propagates into accuracy of the final coordinates of newly determined points it is essential to restrict the space of the control points to the above described limits. If one adopts the usual approach of surrounding the object by known control points then

  7. Study on Korean Radiological Emergency System-Care System- and National Nuclear Emergency Preparedness System Development

    International Nuclear Information System (INIS)

    Akhmad Khusyairi; Yudi Pramono

    2008-01-01

    Care system; Radiological Emergency Supporting System. Environmental radiology level is the main aspect that should be concerned deal with the utilization of nuclear energy. The usage of informational technology in nuclear area gives significant contribution to anticipate and to protect human and environment. Since 1960, South Korea has developed environment monitoring system as the effort to protect the human and environment in the radiological emergency condition. Indonesia has possessed several nuclear installations and planned to build and operate nuclear power plants (PLTN) in the future. Therefore, Indonesia has to prepare the integrated system, technically enables to overcome the radiological emergency. Learning from the practice in South Korea, the system on the radiological emergency should be prepared and applied in Indonesia. However, the government regulation draft on National Radiological Emergency System, under construction, only touches the management aspect, not the technical matters. Consequently, when the regulation is implemented, it will need an additional regulation on technical aspect including the consideration on the system (TSS), the organization of operator and the preparation of human resources development of involved institution. For that purpose, BAPETEN should have a typical independence system in regulatory frame work. (author)

  8. Digital simulation of power electronic systems

    International Nuclear Information System (INIS)

    Mehring, P.; Jentsch, W.; John, G.; Kraemer, D.

    1981-01-01

    The following paper contains the final report on the NETSIM-Project. The purpose of this project is to develop a special digital simulation system, which could serve as a base for routine application of simulation in planning and development of power electronic systems. The project is realized in two steps. First a basic network analysis system is established. With this system the basic models and methods in treating power electronic networks could be probed. The resulting system is then integrated into a general digital simulation system for continous systems (CSSL-System). This integrated simulation system allows for convenient modeling and simulation of power electronic systems. (orig.) [de

  9. Development of digital low level rf system

    International Nuclear Information System (INIS)

    Michizono, Shinichiro; Anami, Shozo; Katagiri, Hiroaki; Fang, Zhigao; Matsumoto, Toshihiro; Miura, Takako; Yano, Yoshiharu; Yamaguchi, Seiya; Kobayashi, Tetsuya

    2008-01-01

    One of the biggest advantages of the digital low level rf (LLRF) system is its flexibility. Owing to the recent rapid progress in digital devices (such as ADCs and DACs) and telecommunication devices (mixers and IQ modulators), digital LLRF system becomes popular in these 10 years. The J-PARC linac LLRF system adopted cPCI crates and FPGA based digital feedback system. Since the LLRF control of the normal conducting cavities are more difficult than super conducting cavities due to its lower Q values, fast processing using the FPGA was the essential to the feedback control. After the successful operation of J-PARC linac LLRF system, we developed the STF (ILC test facility in KEK) LLRF system. Since the klystron drives eight cavities in STF phase 1, we modified the FPGA board. Basic configuration and the performances of these systems are summarized. The future R and D projects (ILC and ERL) is also described from the viewpoints of LLRF. (author)

  10. Radiological changes of the hands of systemic sclerosis

    International Nuclear Information System (INIS)

    Brun, B.; Serup, J.; Hagdrup, H.

    1983-01-01

    Radiological examination of the hands was performed in 41 patients with systemic sclerosis. Pathological changes were found in 39 patients. Eighteen patients had subcutaneous calcifications and 11 had atrophy of the finger pulps. Bone resorption of ungual tufts was found in 11 patients. Juxta-articular osteoporosis was seen in 9 patients and periarticular bone erosions in 8 patients indicating erosive arthropathy. Osteoarthritis and generalized osteoporosis were seen in 10 and 7 patients, respectively. Radiological examination of the hands is recommended during treatment. (Authors)

  11. A multi-channel waveform digitizer system

    International Nuclear Information System (INIS)

    Bieser, F.; Muller, W.F.J.

    1990-01-01

    The authors report on the design and performance of a multichannel waveform digitizer system for use with the Multiple Sample Ionization Chamber (MUSIC) Detector at the Bevalac. 128 channels of 20 MHz Flash ADC plus 256 word deep memory are housed in a single crate. Digital thresholds and hit pattern logic facilitate zero suppression during readout which is performed over a standard VME bus

  12. Development of digital subtraction system DAR-1200

    International Nuclear Information System (INIS)

    Kawai, Masumi; Shimizu, Yasumitsu; Ozaki, Takeshi; Sawada, Hiroshi; Uzuyama, Kazuhiro; Nishioka, Hiroyuki

    1989-01-01

    Digital subtraction angiography (DSA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. The merits of Shimadzu high resolution digital subtraction system DAR-1200 are reported in this paper. Furthermore, the principle and clinical usefullness of a new method of DSA called the Peak-Hold DSA are explained especially in details. (author)

  13. Development of a real-time radiological dose assessment system

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Hee; Lee, Young Bok; Kim, Eun Han; Suh, Kyung Suk; Hwang, Won Tae; Choi, Young Gil

    1997-07-01

    A radiological dose assessment system named FADAS has been developed. This system is necessary to estimated the radiological consequences against a nuclear accident. Mass-consistent wind field module was adopted for the generation of wind field over the whole domain using the several measured wind data. Random-walk dispersion module is used for the calculation of the distribution of radionuclides in the atmosphere. And volume-equivalent numerical integration method has been developed for the assessment of external gamma exposure given from a randomly distributed radioactive materials and a dose data library has been made for rapid calculation. Field tracer experiments have been carried out for the purpose of analyzing the site-specific meteorological characteristics and increasing the accuracy of wind field generation and atmospheric dispersion module of FADAS. At first, field tracer experiment was carried out over flat terrain covered with rice fields using the gas samplers which were designed and manufactured by the staffs of KAERI. The sampled gas was analyzed using gas chromatograph. SODAR and airsonde were used to measure the upper wind. Korean emergency preparedness system CARE was integrated at Kori 4 nuclear power plants in 1995. One of the main functions of CARE is to estimate the radiological dose. The developed real-time dose assessment system FADAS was adopted in CARE as a tool for the radiological dose assessment. (author). 79 refs., 52 tabs., 94 figs.

  14. Radiation Detection System for Prevention of Radiological and Nuclear Terrorism

    International Nuclear Information System (INIS)

    Kwak, Sung-Woo; Yoo, Ho-Sik; Jang, Sung-Sun; Kim, Jae-Kwang; Kim, Jung-Soo

    2007-01-01

    After the September 11 terrorist attack, the threat of a potential for a radiological or nuclear terrorist attack became more apparent. The threats relating to radiological or nuclear materials include a Radiological Dispersion Device (RDD), an Improved Nuclear Device (IND) or a State Nuclear Device (such as a Soviet manufactured suitcase nuclear weapon). For more effective countermeasures against the disaster, multilayer protection concept - prevention of smuggling of radioactive or nuclear material into our country through seaports or airports, detection and prevention of the threat materials in transit on a road, and prevention of their entry into a target building - is recommended. Due to different surrounding circumstances of where detection system is deployed, different types of radiation detection systems are required. There have been no studies on characteristics of detection equipment required under Korean specific conditions. This paper provides information on technical requirements of radiation detection system to achieve multi-layer countermeasures for the purpose of protecting the public and environment against radiological and nuclear terrorism

  15. Digital Traces of Information Systems

    DEFF Research Database (Denmark)

    Hedman, Jonas; Srinivasan, Nikhil; Lindgren, Rikard

    2013-01-01

    . This disconcerting result suggests that IS researchers must pay more attention to the changing landscape of data sources. To motivate and guide fellow colleagues to establish the credibility and reliability of digital traces, we develop a future research agenda that covers both opportunities in theory generation...

  16. Analog and digital communication systems

    CERN Document Server

    Roden, Martin S

    1996-01-01

    New edition of an introductory text that balances theoretical foundations with practical design. Reorganization and updates in this edition include the section on digital communications as well as design applications and computer exercises: many graphs are prepared and formulas solved using MATLAB...

  17. Quantitative risk assessment of digitalized safety systems

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sung Min; Lee, Sang Hun; Kang, Hym Gook [KAIST, Daejeon (Korea, Republic of); Lee, Seung Jun [UNIST, Ulasn (Korea, Republic of)

    2016-05-15

    A report published by the U.S. National Research Council indicates that appropriate methods for assessing reliability are key to establishing the acceptability of digital instrumentation and control (I and C) systems in safety-critical plants such as NPPs. Since the release of this issue, the methodology for the probabilistic safety assessment (PSA) of digital I and C systems has been studied. However, there is still no widely accepted method. Kang and Sung found three critical factors for safety assessment of digital systems: detection coverage of fault-tolerant techniques, software reliability quantification, and network communication risk. In reality the various factors composing digitalized I and C systems are not independent of each other but rather closely connected. Thus, from a macro point of view, a method that can integrate risk factors with different characteristics needs to be considered together with the micro approaches to address the challenges facing each factor.

  18. Experimental OAI-Based Digital Library Systems

    Science.gov (United States)

    Nelson, Michael L. (Editor); Maly, Kurt (Editor); Zubair, Mohammad (Editor); Rusch-Feja, Diann (Editor)

    2002-01-01

    The objective of Open Archives Initiative (OAI) is to develop a simple, lightweight framework to facilitate the discovery of content in distributed archives (http://www.openarchives.org). The focus of the workshop held at the 5th European Conference on Research and Advanced Technology for Digital Libraries (ECDL 2001) was to bring researchers in the area of digital libraries who are building OAI based systems so as to share their experiences, problems they are facing, and approaches they are taking to address them. The workshop consisted of invited talks from well-established researchers working in building OAI based digital library system along with short paper presentations.

  19. Modeling of digital communication systems using SIMULINK

    CERN Document Server

    Giordano, Arthur A

    2015-01-01

    Arthur Giordano, PhD, is a consultant in the field of military and commercial communications specializing in wireless communications. He is a co-founder of G5 Scientific, LLC, is a senior member of the IEEE and has taught graduate communications courses. He has developed numerous models using MathWorks®' SIMULINK®® to characterize digital communications systems. Allen Levesque, PhD, is a consultant specializing in digital communications systems, and is a partner in G5 Scientific, LLC. He has taught graduate courses in digital communications at Worcester Polytechnic Institute and is currently

  20. Photogrammetry, Digital mapping and Land Informations Systems

    DEFF Research Database (Denmark)

    Frederiksen, Poul

    1998-01-01

    Monitoring activities on photogrammetry, digital mapping and land information systems in State Land Service in Latvia in relation to the EU Phare Project Phase II, Technical Assistance to land Privatisation and registration in Latvia.......Monitoring activities on photogrammetry, digital mapping and land information systems in State Land Service in Latvia in relation to the EU Phare Project Phase II, Technical Assistance to land Privatisation and registration in Latvia....

  1. Single Bit Radar Systems for Digital Integration

    OpenAIRE

    Bjørndal, Øystein

    2017-01-01

    Small, low cost, radar systems have exciting applications in monitoring and imaging for the industrial, healthcare and Internet of Things (IoT) sectors. We here explore, and show the feasibility of, several single bit square wave radar architectures; that benefits from the continuous improvement in digital technologies for system-on-chip digital integration. By analysis, simulation and measurements we explore novel and harmonic-rich continuous wave (CW), stepped-frequency CW (SFCW) and freque...

  2. Carolina Power and Light Company's computerized Radiological Information Management System

    International Nuclear Information System (INIS)

    Meyer, B.A.

    1987-01-01

    Carolina Power and Lignt Company has recently implement a new version of their computerized Radiological Information management System. The new version was programmed in-house and is run on the Company's mainframe computers. In addition to providing radiation worker dose histories and current dose updates, the system provides real-time access control for all three of the Company's nuclear plants such as respirator and survey equipment control and inventory, TLD QC records, and many other functions

  3. High Density Digital Data Storage System

    Science.gov (United States)

    Wright, Kenneth D., II; Gray, David L.; Rowland, Wayne D.

    1991-01-01

    The High Density Digital Data Storage System was designed to provide a cost effective means for storing real-time data from the field-deployable digital acoustic measurement system. However, the high density data storage system is a standalone system that could provide a storage solution for many other real time data acquisition applications. The storage system has inputs for up to 20 channels of 16-bit digital data. The high density tape recorders presently being used in the storage system are capable of storing over 5 gigabytes of data at overall transfer rates of 500 kilobytes per second. However, through the use of data compression techniques the system storage capacity and transfer rate can be doubled. Two tape recorders have been incorporated into the storage system to produce a backup tape of data in real-time. An analog output is provided for each data channel as a means of monitoring the data as it is being recorded.

  4. Digital Components in Swedish NPP Power Systems

    International Nuclear Information System (INIS)

    Karlsson, Mattias; Eriksson, Tage

    2015-01-01

    Swedish nuclear power plants have over the last 20 years of operation modernised or exchanged several systems and components of the electrical power system. Within these works, new components based on digital technology have been employed in order to realize functionality that was previously achieved by using electro-mechanical or analogue technology. Components and systems such as relay protection, rectifiers, inverters, variable speed drives and diesel-generator sets are today equipped with digital components. Several of the systems and components fulfil functions with a safety-role in the NPP. Recently, however, a number of incidents have occurred which highlight deficiencies in the design or HMI of the equipment, which warrants questions whether there are generic problems with some applications of digital components that needs to be addressed. The use of digital components has presented cost effective solutions, or even the only available solution on the market enabling a modernisation. The vast majority of systems using digital components have been operating without problems and often contribute to improved safety but the challenge of non-detectable, or non-identifiable, failure modes remain. In this paper, the extent to which digital components are used in Swedish NPP power systems will be presented including a description of typical applications. Based on data from maintenance records and fault reports, as well as interviews with designers and maintenance personnel, the main areas where problems have been encountered and where possible risks have been identified will be described. The paper intends to investigate any 'tell-tales' that could give signals of unwanted behaviour. Furthermore, particular benefits experienced by using digital components will be highlighted. The paper will also discuss the safety relevance of these findings and suggest measures to improve safety in the application of digital components in power systems. (authors)

  5. Digital subtraction angiography system evaluation with phantoms

    International Nuclear Information System (INIS)

    Wenstrup, R.S.; Sweeney, K.P.; Scholz, F.J.

    1985-01-01

    Advances in digital subtraction angiography imaging demonstrate the need for critical evaluation of the performance of digital subtraction equipment. The design of a phantom set for noninvasive assessment of the imaging quality of digital subtraction equipment is described; components include a remotely controlled transport system and individual patterns to evaluate the contrast and detail properties of the image intensifier, low-contrast sensitivity and resolution of the system, geometric distortion of image, linearity, mechanical and electronic stability of equipment, and effects of bone and bowel gas on iodine perception. The performance of an add-on digital radiographic system is presented, along with radiation exposure levels at the image intensifier for a range of radiographic techniques

  6. Radiologically detectable musculoskeletal involvement in systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Jimenez, M. M.; Manjon, P.; Diaz de Bustamante, T.; Galindo, M.; Buj, M. J.; Cabezudo, J.

    2000-01-01

    We show a wide spectrum of musculoskeletal involvement in systemic lupus erythematosus (SLE) that can be detected by radiological examination. We determined the indications of different imaging techniques in the diagnosis and follow-up of this disease. We reviewed the clinical and radiological histories of 37 patients diagnosed as having SLE on the basis of serological and musculoskeletal criteria. We assessed the personal data of each patient, the association of the disease with autoimmune processes, serology, treatment and radiological findings using plain X ray, ultrasound, computed tomography (CT) and magnetic resonance (MR). Of the 37 cases reviewed, only ten presented changes in one or more of the imaging studies performed. the most common radiological finding was symmetric poly arthritis located at different sites. Other signs included avascular necrosis (late and early), inflammation and tendon and/or ligament rupture, nonerosive deforming arthropathies , soft tissue calcifications and arthritis (staphylococcal and tuberculous). A direct correlation was established between the anticardiolipin antibody titer, steroid doses and avascular necrosis. In SLE, radiologically detectable osteoarticular lesions are uncommon. Symmetric polyarthritis is the earliest lesion and that occurring most frequently. Other signs do not appear as often, with the exception of osteonecrosis, which usually occurs late. It developed early and was unusually aggressive in two youths with elevated anticardiolipin antibody titers and substantial systemic involvement in our series. The contributions of ultrasound and MR in the assessment of musculoskeletal involvement in SLE are especially relevant in the study of inflammations and tendon rupture and in the management of avascular necrosis, respectively. (Author) 17 refs

  7. The radiological assessment system for consequence analysis - RASCAL

    International Nuclear Information System (INIS)

    Sjoreen, A.L.; Ramsdell, J.V.; Athey, G.F.

    1996-01-01

    The Radiological Assessment System for Consequence Analysis, Version 2.1 (RASCAL 2.1) has been developed for use during a response to radiological emergencies. The model estimates doses for comparison with U.S. Environmental Protection Agency (EPA) Protective Action Guides (PAGs) and thresholds for acute health effects. RASCAL was designed to be used by U.S. Nuclear Regulatory Commission (NRC) personnel who report to the site of a nuclear accident to conduct an independent evaluation of dose and consequence projections and personnel who conduct training and drills on emergency responses. It allows consideration of the dominant aspects of the source term, transport, dose, and consequences. RASCAL consists of three computational tools: ST-DOSE, FM-DOSE, and DECAY. ST-DOSE computes source term, atmospheric transport, and dose to man from accidental airborne releases of radionuclides. The source-term calculations are appropriate for accidents at U.S. power reactors. FM-DOSE computes doses from environmental concentrations of radionuclides in the air and on the ground. DECAY computes radiological decay and daughter in-growth. RASCAL 2.1 is a DOS application that can be run under Windows 3.1 and 95. RASCAL has been the starting point for other accident consequence models, notably INTERRAS, an international version of RASCAL, and HASCAL, an expansion of RASCAL that will model radiological, biological, and chemical accidents

  8. Compression of digital images in radiology. Results of a consensus conference; Kompression digitaler Bilddaten in der Radiologie. Ergebnisse einer Konsensuskonferenz

    Energy Technology Data Exchange (ETDEWEB)

    Loose, R. [Klinikum Nuernberg-Nord (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie; Braunschweig, R. [BG Kliniken Bergmannstrost, Halle/Saale (Germany). Klinik fuer Bildgebende Diagnostik und Interventionsradiologie; Kotter, E. [Universitaetsklinikum Freiburg (Germany). Abt. Roentgendiagnostik; Mildenberger, P. [Mainz Univ. (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Simmler, R.; Wucherer, M. [Klinikum Nuernberg (Germany). Inst. fuer Medizinische Physik

    2009-01-15

    Purpose: Recommendations for lossy compression of digital radiological DICOM images in Germany by means of a consensus conference. The compression of digital radiological images was evaluated in many studies. Even though the results demonstrate full diagnostic image quality of modality-dependent compression between 1:5 and 1:200, there are only a few clinical applications. Materials and Methods: A consensus conference with approx. 80 interested participants (radiology, industry, physics, and agencies) without individual invitation was organized by the working groups AGIT and APT of the German Roentgen Society DRG to determine compression factors without loss of diagnostic image quality for different anatomical regions for CT, CR/DR, MR, RF/XA examinations. The consent level was specified as at least 66 %. Results: For individual modalities the following compression factors were recommended: CT (brain) 1:5, CT (all other applications) 1:8, CR/DR (all applications except mammography) 1:10, CR/DR (mammography) 1:15, MR (all applications) 1:7, RF/XA (fluoroscopy, DSA, cardiac angio) 1:6. The recommended compression ratios are valid for JPEG and JPEG 2000 /Wavelet compressions. Conclusion: The results may be understood as recommendations and indicate limits of compression factors with no expected reduction of diagnostic image quality. They are similar to the current national recommendations for Canada and England. (orig.)

  9. Digital cine-imaging

    International Nuclear Information System (INIS)

    Masuda, Kazuhiro

    1992-01-01

    Digitization of fluoroscopic images has been developed for the digital cine imaging system as a result of the computer technology, television technology, and popularization of interventional radiology. Present digital cine imaging system is able to offer images similar to cine film because of the higher operatability and better image quality with the development of interventional radiology. As a result, its higher usefulness for catheter diagnosis examination except for interventional radiology was reported, and the possibility of having filmless cine is close to becoming a reality. However several problems have been pointed out, such as spatial resolution, time resolution, storage and exchangeability of data, disconsolidated viewing functions, etc. Anyhow, digital cine imaging system has some unresolved points and lots the needs to be discussed. The tendency of digitization is the passage of the time and we have to promote a study for more useful digital cine imaging system in team medical treatment which centers on the patients. (author)

  10. Digital radiography

    International Nuclear Information System (INIS)

    Coulomb, M.; Dal Soglio, S.; Pittet-Barbier, L.; Ranchoup, Y.; Thony, F.; Ferretti, G.; Robert, F.

    1992-01-01

    Digital projection radiography may replace conventional radiography some day, provided it can meet several requirements: equal or better diagnostic effectiveness of the screen-film systems; reasonable image cost; real improvement in the productivity of the Departments of Imaging. All digital radiographic systems include an X-ray source, an image acquisition and formatting sub-system, a display and manipulation sub-system, and archiving subsystem and a laser editing system, preferably shared by other sources of digital images. Three digitization processes are available: digitization of the radiographic film, digital fluorography and phospholuminescent detectors with memory. The advantages of digital fluoroscopy are appealing: real-time image acquisition, suppression of cassettes; but its disadvantages are far from negligible: it cannot be applied to bedside radiography, the field of examination is limited, and the wide-field spatial resolution is poor. Phospholuminescent detectors with memory have great advantages: they can be used for bedside radiographs and on all the common radiographic systems; spatial resolution is satisfactory; its current disadvantages are considerable. These two systems, have common properties making up the entire philosophy of digital radiology and specific features that must guide our choice according to the application. Digital fluorography is best applied in pediatric radiology. However, evaluation works have showed that it was applicable with sufficient quality to many indications of general radiology in which a fluoroscopic control and fast acquisition of the images are essential; the time gained on the examination may be considerable, as well as the savings on film. Detectors with memory are required for bedside radiographs, in osteoarticular and thoracic radiology, in all cases of traumatic emergency and in the resuscitation and intensive care departments

  11. Improvement of the Radiological system of emergency classification in Cuba

    International Nuclear Information System (INIS)

    Jerez Vegueria, Pablo F.; Yamil Lopez Forteza; Diaz Guerra, Pedro I.

    2003-01-01

    In 1998 the National Center of Nuclear Security (CNSN), on the base of the experience in the one handling of emergencies and the preparation aspects, planning and answer, it perfects and it modernizes, with the approval of the national bigger State of the Civil Defense, the approaches of the Scale of Radiological Events approved from 1992. Given the operational experience of the System of Answer to Emergency of the Ministry Of Science Technology And Environment in the year 2001 the CNSN develops, it perfects and it puts in vigor a more complete System of Classification of Emergency of unique use for all the entities that use sources of radiations ionizations and that it also includes those answer forces that are imbricate in the Plan of Measures Against Catastrophe for cases of Radiological Accidents. The setting in vigor of this Unique System of Classification of Emergencies at national level has allowed to secure the coordination, planning and answer in an effective, quick and effective way. Presently work is exposed the philosophy on which this System of Classification was elaborated, the approaches used to classify the events as much in radioactive facilities as in the practice of the transport of radioactive materials and the activation of the forces of answers in cases of radiological emergencies

  12. Radiologic-anatomic correlation of thoracic vertebrae and rib shadows in chest digital radiograph

    International Nuclear Information System (INIS)

    Yamaguchi, Isao; Itoh, Harumi

    2007-01-01

    The purpose of this study was to provide an introduction to parsing the radiologic appearance of thoracic vertebrae and ribs. In the study, the radiologic-anatomic correlation technique was applied to promote further understanding of normal chest radiographs. The thoracic vertebrae and ribs of chest radiographs were compared with each macroscopic radiologic and computed tomography (CT) image. The rib parsed the linear shadow of the body of the rib. The macroscopic and radiologic images of thoracic vertebrae and ribs were evaluated to explain their normal radiologic findings. The results of such correlation were summarized as follows: The lamina of the vertebral arch was visualized due to anterior rotation of the upper thoracic vertebrae. The density ratio of the thoracic-vertebrae shadow was almost the same in the vertebral body and vertebral arch. The linear shadow superimposed on the rib corresponded to the inferior margin of the rib. The radiologic-anatomic correlation technique was useful to evaluate normal radiologic findings, and the study was useful to radiological technologists. (author)

  13. A radiological accident consequence assessment system for Hong Kong

    International Nuclear Information System (INIS)

    Wong, M.C.; Lam, H.K.

    1993-01-01

    An account is given of the Hong Kong Radiological Accident Consequence Assessment System which would be used to assess the potential consequences of an emergency situation involving atmospheric release of radioactive material. The system has the capability to acquire real-time meteorological information from the Observatory's network of automatic stations, synoptic stations in the nearby region as well as forecast data from numerical prediction models. The system makes use of these data to simulate the transport and dispersion of the released radioactive material. The effectiveness of protective action on the local population is also modeled. The system serves as a powerful aid in the protective action recommendation processes

  14. Digital system design with VHDL

    International Nuclear Information System (INIS)

    Kang, Jin Gu; Lee, Da Young; Song, Je Chel

    2000-09-01

    This book is comprised of eleven chapters, which are review of basic logic design including combinational logic circuit, KARNAUGH MAPS, Hazard of combinational circuit, Melay order circuit design and synchronous design, introduction of VHDL like VHDL module of Multiplexer and VHDL Function, design with PLD for program, circuit design for arithmetical operation, digital design using SM chart, PGA and CPLD design, Floating-point calculation, extra issues on VHDL, VHDL module for memory and bus,design for hardware test and a testing and examples for design such as UART design and M68HC05 micro controller.

  15. An Introduction to Digital Rights Management Systems

    NARCIS (Netherlands)

    Jonker, Willem

    2007-01-01

    This chapter gives a concise introduction to digital rights management (DRM) systems by first presenting the basic ingredients of the architecture of DRM systems for (audio and/or video) content delivery, followed by an introduction to two open-standard DRM systems, one developed in the mobile world

  16. General digitalized system on nuclear power plants

    International Nuclear Information System (INIS)

    Akagi, Katsumi; Kadohara, Hozumi; Taniguchi, Manabu

    2000-01-01

    Hitherto, instrumentation control system in a PWR nuclear power plant has stepwisely adopted digital technology such as application of digital instrumentation control device to ordinary use (primary/secondary system control device, and so on), application of CRT display system to monitoring function, and so forth, to realize load reduction of an operator due to expansion of operation automation range, upgrading of reliability and maintenance due to self-diagnosis function, reduction of mass in cables due to multiple transfer, and upgrading of visual recognition due to information integration. In next term PWR plant instrumentation control system, under consideration of application practice of conventional digital technology, application of general digitalisation system to adopt digitalisation of overall instrumentation control system containing safety protection system, and central instrumentation system (new type of instrumentation system) and to intend to further upgrade economics, maintenance, operability/monitoring under security of reliability/safety is planned. And, together with embodiment of construction program of the next-term plant, verification at the general digitalisation proto-system aiming at establishment of basic technology on the system is carried out. Then, here was described on abstract of the general digitalisation system and characteristics of a digital type safety protection apparatus to be adopted in the next-term plant. (G.K.)

  17. Regional views on the new system of radiological protection

    International Nuclear Information System (INIS)

    Yoda, N.; Fujimoto, K.; Miyamaru, K.; Lee, J.; Loy, J.; Pan, Z.Q.

    2005-01-01

    This document takes stock on the second session of the second Asian regional conference. In this session, japanese regulators, researchers and operators presented their regional views on the new ICRP recommendations. It was commonly expressed that an understanding of the background to the introduced concepts in the new recommendations is required. Other regional views from Korea, Australia and China were also expressed, based on their own regulatory system and referring to radiological protection topics in their countries. (A.L.B.)

  18. Evaluation system for the analysis of the radiological consequences (RASCAL)

    International Nuclear Information System (INIS)

    Miguel Martinez, M. J. de

    2011-01-01

    The code currently employed by the Spanish Nuclear power is the IRDAM (Interactive Rapid Dose Assessment Model). This code will now be replaced by the RASCAL (Radiological Assessment System for Consequence Analysis) version 4.0. This is a significant improvement in dose calculation for escapes to the atmosphere for radioactive emergencies. The main objective is to highlight the most significant changes introduced in the RASCAL when performing these dose estimates.

  19. Digital image display system for emergency room

    International Nuclear Information System (INIS)

    Murry, R.C.; Lane, T.J.; Miax, L.S.

    1989-01-01

    This paper reports on a digital image display system for the emergency room (ER) in a major trauma hospital. Its objective is to reduce radiographic image delivery time to a busy ER while simultaneously providing a multimodality capability. Image storage, retrieval, and display will also be facilitated with this system. The system's backbone is a token-ring network of RISC and personal computers. The display terminals are higher- function RISC computers with 1,024 2 color or gray-scale monitors. The PCs serve as administrative terminals. Nuclear medicine, CT, MR, and digitized film images are transferred to the image display system

  20. Radiological information management system (RadIMS)

    International Nuclear Information System (INIS)

    Oesterling, R.G.; Marko, S.A.; Tschaeche, A.N.

    1991-01-01

    Westinghouse Idaho Nuclear Company, Inc. (WINCO) is developing and implementing an information management system, known as RadIMS, to track and record personnel exposure to ionizing radiation. RadIMS has been designed to fulfill all the requirements of US Department of Energy (USDOE) Order 5480.11, ''Radiation Protection for Occupational Workers.'' This Order requires the contractor to maintain detailed radiation exposure records on all individuals who work at the facility. These records must be retrievable for the entire working life of the individual and be available to other USDOE contractors on request. To meet these general needs, RadIMS provides for retrieval of detailed, comprehensive individual exposure histories as well as the usual online interactions to accomplish day-today radiation protection operations. These two extremes of functionality require different approaches in the WINCO computing environment. The exposure histories include database text, paper, microfilm, and electronic bitmaps

  1. Radiological information management system (RadIMS)

    Energy Technology Data Exchange (ETDEWEB)

    Oesterling, R.G.; Marko, S.A.; Tschaeche, A.N.

    1991-08-19

    Westinghouse Idaho Nuclear Company, Inc. (WINCO) is developing and implementing an information management system, known as RadIMS, to track and record personnel exposure to ionizing radiation. RadIMS has been designed to fulfill all the requirements of US Department of Energy (USDOE) Order 5480.11, Radiation Protection for Occupational Workers.'' This Order requires the contractor to maintain detailed radiation exposure records on all individuals who work at the facility. These records must be retrievable for the entire working life of the individual and be available to other USDOE contractors on request. To meet these general needs, RadIMS provides for retrieval of detailed, comprehensive individual exposure histories as well as the usual online interactions to accomplish day-today radiation protection operations. These two extremes of functionality require different approaches in the WINCO computing environment. The exposure histories include database text, paper, microfilm, and electronic bitmaps.

  2. Radiological information management system (RadIMS)

    Energy Technology Data Exchange (ETDEWEB)

    Oesterling, R.G.; Marko, S.A.; Tschaeche, A.N.

    1991-08-19

    Westinghouse Idaho Nuclear Company, Inc. (WINCO) is developing and implementing an information management system, known as RadIMS, to track and record personnel exposure to ionizing radiation. RadIMS has been designed to fulfill all the requirements of US Department of Energy (USDOE) Order 5480.11, ``Radiation Protection for Occupational Workers.`` This Order requires the contractor to maintain detailed radiation exposure records on all individuals who work at the facility. These records must be retrievable for the entire working life of the individual and be available to other USDOE contractors on request. To meet these general needs, RadIMS provides for retrieval of detailed, comprehensive individual exposure histories as well as the usual online interactions to accomplish day-today radiation protection operations. These two extremes of functionality require different approaches in the WINCO computing environment. The exposure histories include database text, paper, microfilm, and electronic bitmaps.

  3. A new digital land mobile satellite system

    Science.gov (United States)

    Schneider, Philip

    A description is given of the different digital services planned to be carried over existing and planned mobile satellite systems. These systems are then compared with analog services in terms of bandwidth and power efficiency. This comparison provides the rationale for the establishment of a digital land mobile satellite service (DLMSS) to use frequencies that are currently available but not yet assigned to a domestic mobile satellite system in the United States. The focus here is on the expected advantages of digital transmission techniques in accommodating additional mobile satellite systems in this portion of the spectrum, and how such techniques can fully satisfy voice, data and facsimile mobile communications requirements in a cost effective manner. A description is given of the system architecture of the DMLSS service proposed by the Geostar Messaging Corporation (GMC) and the market potential of DLMSS.

  4. Comparison of incident air kerma (ki) of common digital and analog radiology procedures in Kohgiluyeh and Boyer-Ahmad province

    Science.gov (United States)

    Vafapour, Hassan; Salehi, Zaker

    2018-03-01

    Introduction: Although in many developed countries, Analog radiography (AR) is replaced with digital radiography (DR) but AR is still widely used in many countries included Iran. Therefore, dosimetrically assessment of delivered dose is very important to avoid unnecessary patient dose. Materials and Methods: In this study, all imaging centers in Kohgiluyeh and Boyer-Ahmad were selected. The initial information included the mean kVp and mAs used by the personnel to perform each radiological procedure were gathered through a questionnaire. Barracuda dosimeter was then used to measure Incident air kerma (ki). Data obtained from digital radiography (DR) and analogue radiography (AR) were then analyzed and compared to each other. Results: The mean incident air kerma (ki) for five radiological procedures (chest AP&Lat, Skull AP&Lat, Lumbar spine AP&Lat, Thoracic spine AP&Lat and Pelvis) in digital devices were 0.38&1.34, 2.1&1.94, 4.99&7.83, 4.18& 6.41 and 4.33 mGy and those for analogue devices were 0.7&1.28, 3.05&3.02, 7.25&9.9, 7.125&8.36 and 5.36 mGy, respectively. Discussion and Conclusion: The use of low kVp or high mAs is one of the reasons to increase the incident air kerma (ki) in analogue methods comparing to digital methods in all procedures except the chest (in Lateral view). Also the results, surprisingly, showed that in some of the analogue methods incident air kerma (ki) was less than digital methods which is most probably because of the auto-exposure conditions.

  5. Radiation monitoring systems and methodologies for radiological impact assessment

    International Nuclear Information System (INIS)

    Chaudhury, Probal

    2016-01-01

    Radioactive sources of various strengths are used in large number of applications in industry, healthcare, agriculture and research. Though all the sources are transported and used under regulatory control, there is always a possibility of some of the sources getting into the hands of committed antisocial non state actors. In addition to this, there is a possible threat of radioactive material being illegally brought into a country. These gives rise to an increase in the global radiological threat and security experts world over are concerned about the possibility of malicious use of radiation in the public domain. Radiation detection systems are installed at various entry and exit ports of some of the countries to detect illicit trafficking of radioactive materials. IAEA has recommended that all States should have a national response plan for nuclear security events to provide for an appropriate and coordinated response. Considering the requirement of radiological emergency preparedness, various radiation monitoring systems and methodologies have been developed. A few aerial radiation monitoring systems developed at Bhabha Atomic Research Centre (BARC) for radiological impact assessment are described here

  6. Radiologic studies in two outbreaks of isolated vasculitis in the central nervous system

    International Nuclear Information System (INIS)

    Robertson, H.J.; Perez, M.; Tilton, A.H.; Garcia, C.; McGarry, P.

    1989-01-01

    Cerebral vasculitis is only occasionally diagnosed with angiography. Two outbreaks of isolated central nervous system vasculitis permitted a comparison of the accuracy of diagnostic radiologic studies. Two new radiologic features and methods of diagnosis are discussed

  7. SECURING DIGITIZED LIBRARY CIRCULATORY SYSTEM

    African Journals Online (AJOL)

    user

    The widespread application of the developed system on smart library circulation .... database management system; [9] through securing .... system running on a Windows 8 Operating system .... mini library for their support, advice and unlimited.

  8. Ionizing secondary radiation generated by analog radiological and digital coronary cine angiographic equipment. Influence of external protection devices

    International Nuclear Information System (INIS)

    Ramirez N, Alfredo; Farias Ch, Eric; Silva J, Ana Maria; Leyton L, Fernando; Oyarzun C, Carlos; Ugalde P, Hector; Dussaillant, Gaston; Cumsille G, Angel

    2000-01-01

    Exposure to ionizing radiation is a know hazard of radiological procedures. Aim: to compare the emission of secondary ionizing radiation from two coronary angiographic equipments, one with digital and the other with analog image generation. To evaluate the effectiveness of external radiological protection devices. Material and methods: environmental and fluoroscopy generated radiation in the cephalic region of the patient was measured during diagnostic coronary angiographies. Ionizing radiation generated in anterior left oblique protection (ALO) and anterior right oblique protection (ARO) were measured with and without leaded protections. In 19 patients (group 1), a digital equipment was used and in 21 (group 2), an analog equipment. Results: header radiation for group 1 and 2 was 1194±337 and 364±222 μGray/h respectively (p≤0.001). During fluoroscopy and with leaded protection generated radiation for groups 1 and 2 was 612±947 and 70±61μGray/h respectively (p≤0.001). For ALO projection, generated for groups 1 and 2 was 105±47 and 71±192 μGray/h respectively (p≤0.001). During filming the radiation for ALO projection for groups 1 and 2 was 7252±9569 and 1671±2038 μGray/h respectively (p=0.03). Out of the protection zone, registered radiation during fluoroscopy for groups 1 and 2 was 2800±1741 and 1318±954 μGray/h respectively (p≤0.001); during filming, the figures were 15500±5840 and 18961±10599 μGray/h respectively (NS). Conclusions: digital radiological equipment has a lower level of ionizing radiation emission than the analog equipment

  9. RI Mapping System for Identification of Radiological Contamination in Environmental Water Supply System

    Energy Technology Data Exchange (ETDEWEB)

    Na, Teresa W.; Ha, Jang Ho; Kim, Han Soo; Lee, Seung Hyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Na, Teresa W.; Lee, Rena [Ewha Womans Univ., Hospital, Seoul (Korea, Republic of)

    2012-03-15

    The interest of radiation protection has risen due to accidents of the Nuclear Power Plant, nuclear terrorism, and the radiological contamination in the city, In this respect, the development of environmental radiation monitoring for the radiological contaminants has been studied. In this study, the experiment for the radiological contamination in the water supply pipe line system has been simulated and preliminarily tested. The CsI(Tl)-PIN diode detectors were used and the preliminary test of radiation monitoring system was performed as multi detection system. The 2D image reconstruction algorithm was also developed for feasibility of the constructed multi-detection system.

  10. Comprehensive analysis of a Radiology Operations Management computer system.

    Science.gov (United States)

    Arenson, R L; London, J W

    1979-11-01

    The Radiology Operations Management computer system at the Hospital of the University of Pennsylvania is discussed. The scheduling and file room modules are based on the system at Massachusetts General Hospital. Patient delays are indicated by the patient tracking module. A reporting module allows CRT/keyboard entry by transcriptionists, entry of standard reports by radiologists using bar code labels, and entry by radiologists using a specialty designed diagnostic reporting terminal. Time-flow analyses demonstrate a significant improvement in scheduling, patient waiting, retrieval of radiographs, and report delivery. Recovery of previously lost billing contributes to the proved cost effectiveness of this system.

  11. Computer aided system for segmentation and visualization of microcalcifications in digital mammograms

    International Nuclear Information System (INIS)

    Reljin, B.; Reljin, I.; Milosevic, Z.; Stojic, T.

    2009-01-01

    Two methods for segmentation and visualization of microcalcifications in digital or digitized mammograms are described. First method is based on modern mathematical morphology, while the second one uses the multifractal approach. In the first method, by using an appropriate combination of some morphological operations, high local contrast enhancement, followed by significant suppression of background tissue, irrespective of its radiology density, is obtained. By iterative procedure, this method highly emphasizes only small bright details, possible microcalcifications. In a multifractal approach, from initial mammogram image, a corresponding multifractal 'images' are created, from which a radiologist has a freedom to change the level of segmentation. An appropriate user friendly computer aided visualization (CAV) system with embedded two methods is realized. The interactive approach enables the physician to control the level and the quality of segmentation. Suggested methods were tested through mammograms from MIAS database as a gold standard, and from clinical praxis, using digitized films and digital images from full field digital mammograph. (authors)

  12. Computer assisted radiology

    International Nuclear Information System (INIS)

    Lemke, H.U.; Jaffe, C.C.; Felix, R.

    1993-01-01

    The proceedings of the CAR'93 symposium present the 126 oral papers and the 58 posters contributed to the four Technical Sessions entitled: (1) Image Management, (2) Medical Workstations, (3) Digital Image Generation - DIG, and (4) Application Systems - AS. Topics discussed in Session (1) are: picture archiving and communication systems, teleradiology, hospital information systems and radiological information systems, technology assessment and implications, standards, and data bases. Session (2) deals with computer vision, computer graphics, design and application, man computer interaction. Session (3) goes into the details of the diagnostic examination methods such as digital radiography, MRI, CT, nuclear medicine, ultrasound, digital angiography, and multimodality imaging. Session (4) is devoted to computer-assisted techniques, as there are: computer assisted radiological diagnosis, knowledge based systems, computer assisted radiation therapy and computer assisted surgical planning. (UWA). 266 figs [de

  13. An integrated system for conducting radiological surveys of contaminated sites - 16312

    International Nuclear Information System (INIS)

    McCown, Jay P.; Rogers, Donna M.; Waggoner, Charles A.

    2009-01-01

    This paper describes an integrated detection system that has been developed to conduct radiological surveys of sites suspected of contamination of materials such as depleted uranium. This system utilizes cerium activated lanthanum bromide and thallium activated sodium iodide gamma detectors and can be easily adapted to include units for detecting neutrons. The detection system includes software controlling the collection of radiological spectra and GPS data. Two different platforms are described for conducting surveys, a modified zero turn radius (ZTR) mower and a three-wheeled cart that is manually pushed. The detection system software controlling data collection has components that facilitate completing a grid-less survey on user specified spacings. Another package confirms that all data quality activities (calibrations, etc.) are conducted prior to beginning the survey and also reviews data to identify areas that have been missed for which data quality falls below user designated parameters. Advanced digital signal processing algorithms are used to enhance the interpretation of spectra for conducting background subtractions and for mapping. Data from radiation detection instruments and GPS antennae are merged and made compatible with mapping using Geosoft Oasis montaj software. A summary of system performance during field-testing is included in the paper. This includes survey rate, detection limits, duty cycle, supporting ancillary equipment/material, and manpower requirements. The rate of false positives and false negatives is discussed with the benefits of surveys conducted using synergetic detection systems such as electromagnetic induction imaging. (authors)

  14. Life-critical digital flight control systems

    Science.gov (United States)

    Mcwha, James

    1990-01-01

    Digital autopilot systems were first used on commercial airplanes in the late 1970s. The A-320 airplane was the first air transport airplane with a fly-by-wire primary flight control system. On the 767-X (777) airplane Boeing will install all fly-by-wire flight controls. Activities related to safety, industry status and program phases are discussed.

  15. Image digitizer system for bubble chamber laser

    International Nuclear Information System (INIS)

    Haggerty, H.

    1986-01-01

    An IBM PC-based image digitizer system has been assembled to monitor the laser flash used for holography at the 15 foot bubble chamber. The hardware and the operating software are outlined. For an operational test of the system, an array of LEDs was flashed with a 10 microsecond pulse and the image was grabbed by one of the operating programs and processed

  16. DIGITAL SUBSTATION COMPONENT SYSTEM "SMART GRID"

    Directory of Open Access Journals (Sweden)

    V.I. Vasilchenko

    2014-12-01

    Full Text Available New production technologies of modern control systems have moved from the stage of research and experimentation into the stage of practical use. Modern communication standards for the exchange of information are developed and introduced. Digital devices, protectors and automation are widely used. There has been substantial development of hardware and software of control systems.

  17. Radiological study of the chest using the digital method (FCR 101)

    International Nuclear Information System (INIS)

    Ferri, G.; Battolla, L.; Palla, L.; D'Alessandro, F.; Torri, T.; Tagliagambe, A.

    1991-01-01

    A computed radiography system with solid state detectors (FCR 101) was employed to evaluate the quality of digital images, with optimal and progressively lowered doses, in the study of the chest. Routine chest radiographs of in patients with no pathologic conditions of the chest were studied. The patients were divided into 3 groups: each patient in group A underwent two radiographs, one at 100% andthe other at 50% exposure; patients in group B were imaged with 100% and 25% doses, and those in group C received 50% and 25% exposure. Several parameters were employed for image evaluation, and a value was given to each of them (1=good, 2=sufficient, 3=insufficient). Upon comparison of the average values obtained, we observed that the digital technique allowed a most accurate and well-defined representation of the examined parameters at 100% exposure dose and that a 50% reduction did not decrease the informative content of the least. A 25% reduction, however, determined a high degree of background noise and a subsequent, though slight, loss of information

  18. Oscilloscope trace photograph digitizing system (TRACE)

    International Nuclear Information System (INIS)

    Richards, M.; Dabbs, R.D.

    1977-10-01

    The digitizing system allows digitization of photographs or sketches of waveforms and then the computer is used to reduce and analyze the data. The software allows for alignment, calibration, removal of baselines, removal of unwanted points and addition of new points which makes for a fairly versatile system as far as data reduction and manipulation are concerned. System considerations are introduced first to orient the potential user to the process of digitizing information. The start up and actual commands for TRACE are discussed. Detailed descriptions of each subroutine and program section are also provided. Three general examples of typical photographs are included. A partial listing of FAWTEK is made available. Once suitable arrays that contain the data are arranged, ''GO FA'' (active FAWTEK) and many mathematical operations to further analyze the data may be performed

  19. A new digital correlation flaw detection system

    International Nuclear Information System (INIS)

    Lee, B.B.; Furgason, E.S.

    1981-01-01

    A new portable digital random signal flaw detection system is described which uses a digital delay line to replace the acoustic delay line of the original random signal system. Using this new system, a comparison was made between the two types of transmit signals which have been used in previous systems--m-sequences and random signals. This comparison has not been possible with these previous correlation flaw detection systems. Results indicated that for high-speed short code operation, the m-sequences produced slightly lower range sidelobes than typical samples of a clipped random signal. For normal long code operation, results indicated that system performance is essentially equivalent in resolution and signal-to-noise ratio using either m-sequences or clipped and sampled random signals. Further results also showed that for normal long code operation, the system produces outputs equivalent in resolution to pulse-echo systems, but with the added benefit of signal-to-noise ratio enhancement

  20. Diagnostic capability of 100-mm roll film digitizer system

    International Nuclear Information System (INIS)

    Kono, M.; Yamasaki, K.; Ikeda, M.

    1988-01-01

    The authors recently developed a roll film digitizer system. The sampling pitch is 100 μm. a scientific image study (Barger phantom, Hawlet chart, and modulation transfer function), receiver operating characteristic (ROC) study, and clinical evaluation were performed. For the ROC study, a chest phantom with simulated nodule and hairline was used. Differences in accuracy between readings of cathode ray tube (CRT) images and roll film images were not statistically significant for hairline and coin lesions, P<.05). As a clinical evaluation, eight radiologists evaluated predetermined radiologic findings on a five-point rating scale compared with original roll film images. Scores for CRT images were equal to those for the original roll film images. In conclusion, CRT images (1,000 x 1,000) were found to be sufficient for diagnostic accuracy of chest images compared with roll film images (100 x 100 mm)

  1. CRRIS: a computerized radiological risk-investigation system

    International Nuclear Information System (INIS)

    Baes, C.F. III; Miller, C.W.

    1981-01-01

    The US Environmental Protection Agency (EPA) is responsible for regulating radioactive airborne effluents in the US. A comprehensive, integrated Computerized Radiological Risk Investigation System (CRRIS) is being developed to support EPA's radiation standards development. This modular system consists primarily of five computer codes and their supporting data bases for estimating environmental transport and radiation doses and risks. Health effects are estimated on the basis of a life-table methodology developed by EPA. CRRIS is designed to provide EPA with a reasonable and flexible way of assessing the risk to man associated with radionuclide releases to the atmosphere

  2. Evaluation of the lacrimal system by radiological methods

    International Nuclear Information System (INIS)

    Francisco, Fabiano Celli; Francisco, Vivian Frida Murta; Mendonca Junior, Adhemar Azevedo de; Carvalho, Antonio Carlos Pires; Fonseca, Lea Mirian Barbosa da; Gutfilen, Bianca; Francisco, Marina Celli

    2007-01-01

    The authors perform a revisional and iconographic study of the lacrimal system by means of radiological methods, namely, conventional radiography, linear tomography, computed tomography and magnetic resonance imaging. Image methods are essential to define diagnosis and therapy, considering that besides demonstrating alterations of the lacrimal system, they may indicate the patients with better prognosis associated with the surgical approach. Considering the lower cost, lower radiation dose, low rate of complications, and level of information that can be obtained dacryocystography by means of linear tomography is recommended as the initial investigation method. (author)

  3. Digital instrumentation system for nuclear research reactors

    International Nuclear Information System (INIS)

    Aghina, Mauricio A.C.; Carvalho, Paulo Vitor R.

    2002-01-01

    This work describes a proposal for a system of nuclear instrumentation and safety totally digital for the Argonauta Reactor. The system divides in the subsystems: channel of pulses, channel of current, conventional instrumentation and safety system. The connection of the subsystems is made through redundant double local net, using the protocol modbus/rtu. So much the channel of pulses, the current channel and safety's system use modules operating in triple redundancy. (author)

  4. Digital PIV (DPIV) Software Analysis System

    Science.gov (United States)

    Blackshire, James L.

    1997-01-01

    A software package was developed to provide a Digital PIV (DPIV) capability for NASA LaRC. The system provides an automated image capture, test correlation, and autocorrelation analysis capability for the Kodak Megaplus 1.4 digital camera system for PIV measurements. The package includes three separate programs that, when used together with the PIV data validation algorithm, constitutes a complete DPIV analysis capability. The programs are run on an IBM PC/AT host computer running either Microsoft Windows 3.1 or Windows 95 using a 'quickwin' format that allows simple user interface and output capabilities to the windows environment.

  5. Application of a geographic information system for radiologic emergency response

    International Nuclear Information System (INIS)

    Best, R.G.; Doyle, J.F.

    1995-01-01

    A geographic information system (GIS) is a multifunctional analytical tool that can be used to compile available data and derive information. A GIS is a computerized database management system for the capture, storage, retrieval, analysis, and display of spatial data. Maps are the most common type of spatial data, but any type of data that can be referenced by an x-y location or geographic coordinate can be used in a GIS. In a radiological emergency, it is critical that data of all types be rapidly compiled into a common format in order to make accurate observations and informed decisions. Developing a baseline GIS for nuclear facilities would offer a significant incentive for all organizations to contribute to and utilize this powerful data management tool. The system being developed could integrate all elements of emergency planning, from the initial protective actions based on models through the emergency monitoring phase, and finally ending with the complex reentry and recovery phase. Within the Federal Radiological Monitoring and Assessment Center (FRMAC), there is a continuing effort to improve the data management and communication process. To demonstrate the potential of GIS for emergency response, the system has been utilized in interagency FRMAC exercises. An interactive GIS system has been deployed and used to analyze the available spatial data to help determine the impact of a hypothetical radiological release and to develop mitigation plans. For this application, both hardcopy and real-time spatial displays were generated with the GIS. Composite maps with different sizes, scales, and themes were produced to support the exercises

  6. Security Information System Digital Simulation

    OpenAIRE

    Tao Kuang; Shanhong Zhu

    2015-01-01

    The study built a simulation model for the study of food security information system relay protection. MATLAB-based simulation technology can support the analysis and design of food security information systems. As an example, the food security information system fault simulation, zero-sequence current protection simulation and transformer differential protection simulation are presented in this study. The case studies show that the simulation of food security information system relay protect...

  7. Physician-received scatter radiation with angiography systems used for interventional radiology: Comparison among many x-ray systems

    International Nuclear Information System (INIS)

    Chida, K.; Morishima, Y.; Inaba, Y.; Taura, M.; Ebata, A.; Takeda, K.; Shimura, H.; Zuguchi, M.

    2012-01-01

    Radiation protection for interventional radiology (IR) physicians is very important. Current IR X-ray systems tend to use flat-panel detectors (FPDs) rather than image intensifiers (IIs). The purpose of this study is to test the hypothesis that there is no difference in physician-received scatter radiation (PRSR) between FPD systems and II systems. This study examined 20 X-ray systems in 15 cardiac catheterisation laboratories (11 used a FPD and 9 used an II). The PRSR with digital cine-angiography and fluoroscopy were compared among the 20 X-ray systems using a phantom and a solid-state-detector electronic pocket dosemeter. The maximum PRSR exceeded the minimum PRSR by ∼12-fold for cine-angiography and ∼9-fold for fluoroscopy. For both fluoroscopy and digital cine-angiography, the PRSR had a statistically significant positive correlation with the entrance surface dose (fluoroscopy, r = 0.87; cine-angiography, r = 0.86). There was no statistically significant difference between the average PRSR of FPDs and IIs during either digital cine-angiography or fluoroscopy. There is a wide range of PRSR among the radiography systems evaluated. The PRSR correlated well with the entrance surface dose of the phantom in 20 X-ray units used for IR. Hence, decreasing the dose to the patient will also decrease the dose to staff. (authors)

  8. Immunizing digital systems against electromagnetic interference

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.; Antonescu, C.

    1993-01-01

    This paper discusses the development of the technical basis for acceptance criteria applicable to the immunization of digital systems against electromagnetic interference (EMI). The work is sponsored by the US Nuclear Regulatory Commission and stems from the safety-related issues that need to be addressed as a result of the application of digital instrumentation and control systems in nuclear power plants. Designers of digital circuits are incorporating increasingly higher clock frequencies and lower logic level voltages, thereby leading to potentially greater susceptibility of spurious interference being misinterpreted as legitimate logic. Development of the technical basis for acceptance criteria to apply to these digital systems centers around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems. First, good EMC design and installation practices are needed to control the emissions from interference sources and thereby their impact on other nearby circuits and systems. Second, a test and evaluation program is needed to outline the EMI tests to be performed, the associated test methods to be followed, and adequate test limits to ensure that the circuit or system under test meets the recommended guidelines. Test and evaluation should be followed by periodic maintenance to assess whether the recommended EMI control practices continue to be adhered to as part of the routine operation of the nuclear power plant. By following these steps, the probability of encountering safety-related instrumentation problems associated with EMI will be greatly reduced

  9. Immunizing digital systems against electromagnetic interference

    International Nuclear Information System (INIS)

    Ewing, P.D.; Korsah, K.; Antonescu, C.

    1993-01-01

    This paper discusses the development of the technical basis for acceptance criteria applicable to the immunization of digital systems against electromagnetic interference (EMI). The work is sponsored by the US Nuclear Regulatory Commission and stems from the safety-related issues that need to be addressed as a result of the application of digital instrumentation and control systems in nuclear power plants. Designers of digital circuits are incorporating increasingly higher clock frequencies and lower logic level voltages, thereby leading to potentially greater susceptibility of spurious interference being misinterpreted as legitimate logic. Development of the technical basis for acceptance criteria to apply to these digital systems centers around establishing good engineering practices to ensure that sufficient levels of electromagnetic compatibility (EMC) are maintained between the nuclear power plant's electronic and electromechanical systems. First, good EMC design and installation practices are needed to control the emissions from interference sources and thereby their impact on other nearby circuits and systems. Secondly, a test and evaluation program is needed to outline the EMI tests to be performed, the associated test methods to be followed, and adequate test limits to ensure that the circuit or system under test meets the recommended guidelines. Test and evaluation should be followed by periodic maintenance to assess whether the recommended EMI control practices continue to be adhered to as part of the routine operation of the nuclear power plant. By following these steps, the probability of encountering safety-related instrumentation problems associated with EMI will be greatly reduced

  10. Fully Digital Chaotic Differential Equation-based Systems And Methods

    KAUST Repository

    Radwan, Ahmed Gomaa Ahmed

    2012-09-06

    Various embodiments are provided for fully digital chaotic differential equation-based systems and methods. In one embodiment, among others, a digital circuit includes digital state registers and one or more digital logic modules configured to obtain a first value from two or more of the digital state registers; determine a second value based upon the obtained first values and a chaotic differential equation; and provide the second value to set a state of one of the plurality of digital state registers. In another embodiment, a digital circuit includes digital state registers, digital logic modules configured to obtain outputs from a subset of the digital shift registers and to provide the input based upon a chaotic differential equation for setting a state of at least one of the subset of digital shift registers, and a digital clock configured to provide a clock signal for operating the digital shift registers.

  11. Fully Digital Chaotic Differential Equation-based Systems And Methods

    KAUST Repository

    Radwan, Ahmed Gomaa Ahmed; Zidan, Mohammed A.; Salama, Khaled N.

    2012-01-01

    Various embodiments are provided for fully digital chaotic differential equation-based systems and methods. In one embodiment, among others, a digital circuit includes digital state registers and one or more digital logic modules configured to obtain a first value from two or more of the digital state registers; determine a second value based upon the obtained first values and a chaotic differential equation; and provide the second value to set a state of one of the plurality of digital state registers. In another embodiment, a digital circuit includes digital state registers, digital logic modules configured to obtain outputs from a subset of the digital shift registers and to provide the input based upon a chaotic differential equation for setting a state of at least one of the subset of digital shift registers, and a digital clock configured to provide a clock signal for operating the digital shift registers.

  12. Technical self reliance of digital safety systems

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Kee Choon; Lee, Dong Young [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Kook Hun [Doosan Heavy Industries and Construction, Changwon (Korea, Republic of); Choi, Seung Gap [POSCON, Pohang (Korea, Republic of)

    2009-04-15

    This paper summarizes the development results of the Korea Nuclear Instrumentation and Control System (KNICS) project sponsored by the Korean government. In this project, Man Machine Interface System (MMIS) architecture, two digital platforms, and several control systems are developed. One platform is a programmable Logic Controller (PLC) for a safety system and another platform is a Distributed Control System (DCS) for a non safety system. With the POSAFE Q PLC, a Reactor Protection System (RPS) and an Engineered Safety Feature Component Control System (ESF CCS) are developed. A Power Control System (PCS) is developed based on the DCS. The safety grade platform and the digital safety systems obtained approval for the Topical Report from the Korean regulatory body in February of 2009. Also a Korean utility and a vendor company determined KNICS results to apply them to the planned Nuclear Power Plant (NPP) in March 2009. This paper introduces the technical self reliance experiences of the safety grade platform and the digital safety systems developed in the KNICS R and D project.

  13. Quality control procedures of dental diagnostic radiology systems

    International Nuclear Information System (INIS)

    Andrade, Paula Serra Sasaki

    2007-01-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  14. Noise analysis of a digital radiography system

    International Nuclear Information System (INIS)

    Arnold, B.A.; Scheibe, P.O.

    1984-01-01

    The sources of noise in a digital video subtraction angiography system were identified and analyzed. Signal-to-noise ratios of digital radiography systems were measured using the digital image data recorded in the computer. The major sources of noise include quantum noise, TV camera electronic noise, quantization noise from the analog-to-digital converter, time jitter, structure noise in the image intensifier, and video recorder electronic noise. A new noise source was identified, which results from the interplay of fixed pattern noise and the lack of image registration. This type of noise may result from image-intensifier structure noise in combination with TV camera time jitter or recorder time jitter. A similar noise source is generated from the interplay of patient absorption inhomogeneities and patient motion or image re-registration. Signal-to-noise ratios were measured for a variety of experimental conditions using subtracted digital images. Image-intensifier structure noise was shown to be a dominant noise source in unsubtracted images at medium to high radiation exposure levels. A total-system signal-to-noise ratio (SNR) of 750:1 was measured for an input exposure of 1 mR/frame at the image intensifier input. The effect of scattered radiation on subtracted image SNR was found to be greater than previously reported. The detail SNR was found to vary approximately as one plus the scatter degradation factor. Quantization error noise with 8-bit image processors (signal-to-noise ratio of 890:1) was shown to be of increased importance after recent improvements in TV cameras. The results of the analysis are useful both in the design of future digital radiography systems and the selection of optimum clinical techniques

  15. Technical basis for the performance of radiological surveys in support of nuclear facility decommissioning/deactivation utilizing the Laser-Assisted Ranging and Data System (LARADS)

    International Nuclear Information System (INIS)

    Wade, C.D.

    1997-06-01

    This document describes the implementation of the Laser-Assisted Ranging and Data System (LARADS) as it applies to performing radiological surveys on facility exterior and interior surfaces. The LARADS enables the system operator to document scanning measurements, stationary radiological measurements, and sample locations of surfaces, with the radiological readings and exact coordinates (<2 cm [0.8 in.] precision) automatically logged in real-time. After the survey is completed, the information is downloaded to a geographical information system, and the radiological information is overlaid on a digital picture of the survey area or may be generated as a computer- aided drafted drawing. The final product is a track map or contour of the survey area that clearly shows the area covered by the detector and the locations of elevated readings. The exact reproducibility of data facilitates locating hot spots for remediation and provides for objective review by regulators and verifiers

  16. The development of ZPRL digital control system

    International Nuclear Information System (INIS)

    Hsu, Jin-Den; Yang, Sheau-Yieh; Shieh, Der-Jhy.

    1992-01-01

    Zero Power Reactor at Lung-Tan (ZPRL) is a small open-pool type research reactor located at Lung-Tan, Taiwan. The reactor achieved its first criticality in 1971. An analog control system has been used for almost over 20 years and the power regulating function is found gradually out of order. Therefore, we decided to develop a digital control system to replace the existing analog one. A prototype system has been developed and under on-line test now. The proposed ZPRL digital control system consists of three personal computers. These computers are used as (1) operator console, (2) data acquisition and control system, and (3) auxiliary and backup system. The operator console contains all the man-machine interface functions in the form of graphic display. The data acquisition and control system converts the analog signals into digital ones and feeds to the other two computers. The auxiliary and backup system normally emulates a strip chart recorder for the linear and logarithmic neutron powers and also acts as a transient recorder to keep the trace of the operating conditions on demand or when the reactor scrams. On-line test shows that the system does assure a satisfactory performance. It is not only as good as the analog system but also has the advantages of flexibility, testibility, and a user friendly man-machine interface. (author)

  17. Digital System Reliability Test for the Evaluation of safety Critical Software of Digital Reactor Protection System

    Directory of Open Access Journals (Sweden)

    Hyun-Kook Shin

    2006-08-01

    Full Text Available A new Digital Reactor Protection System (DRPS based on VME bus Single Board Computer has been developed by KOPEC to prevent software Common Mode Failure(CMF inside digital system. The new DRPS has been proved to be an effective digital safety system to prevent CMF by Defense-in-Depth and Diversity (DID&D analysis. However, for practical use in Nuclear Power Plants, the performance test and the reliability test are essential for the digital system qualification. In this study, a single channel of DRPS prototype has been manufactured for the evaluation of DRPS capabilities. The integrated functional tests are performed and the system reliability is analyzed and tested. The results of reliability test show that the application software of DRPS has a very high reliability compared with the analog reactor protection systems.

  18. Stability of digital feedback control systems

    Directory of Open Access Journals (Sweden)

    Larkin Eugene

    2018-01-01

    Lag time characteristics are used for investigation of stability of linear systems. Digital PID controller is divided onto linear part, which is realized with a soft and pure lag unit, which is realized with both hardware and software. With use notions amplitude and phase margins, condition for stability of system functioning are obtained. Theoretical results are confirm with computer experiment carried out on the third-order system.

  19. Topographical mapping system for radiological and hazardous environments acceptance testing

    International Nuclear Information System (INIS)

    Armstrong, G.A.; Dochat, G.R.

    1997-01-01

    During the summer of 1996, the Topographical Mapping System (TMS) for hazardous and radiological environments and its accompanying three-dimensional (3-D) visualization tool, the Interactive Computer-Enhanced Remote-Viewing System (ICERVS), were delivered to Oak Ridge National Laboratory (ORNL). ORNL and Mechanical Technology, Inc., performed final acceptance testing of the TMS during the next eight months. The TMS was calibrated and characterized during this period. This paper covers the calibration, characterization, and acceptance testing of the TMS. Development of the TMS and ICERVS was initiated by the US Department of Energy (DOE) for the purpose of characterization and remediation of underground storage tanks (USTs) at DOE sites across the country. DOE required a 3-D, topographical mapping system suitable for use in hazardous and radiological environments. The intended application is the mapping of the interior of USTs as part of DOE's waste characterization and remediation efforts and to obtain baseline data on the content of the storage tank interiors as well as data on changes in the tank contents and levels brought about by waste remediation steps. Initially targeted for deployment at the Hanford Washington site, the TMS is designed to be a self-contained, compact, and reconfigurable system that is capable of providing rapid, variable-resolution mapping information in poorly characterized workspaces with a minimum of operator intervention

  20. Topographical mapping system for radiological and hazardous environments acceptance testing

    Science.gov (United States)

    Armstrong, Gary A.; Dochat, G. R.

    1997-09-01

    During the summer of 1996, the topographical mapping system (TMS) for hazardous and radiological environments and its accompanying three-dimensional (3-D) visualization tool, the interactive computer-enhanced remote-viewing system (ICERVS), were delivered to Oak Ridge National Laboratory (ORNL). ORNL and Mechanical Technology, Inc., performed final acceptance testing of the TMS during the next eight months. The TMS was calibrated and characterized during this period. This paper covers the calibration, characterization, and acceptance testing of the TMS. Development of the TMS and the ICERVS was initiated by the U.S. Department of Energy (DOE) for the purpose of characterization and remediation of underground storage tanks (USTs) at DOE sites across the country. DOE required a 3-D, topographical mapping system suitable for use in hazardous and radiological environments. The intended application is the mapping of the interior of USTs as part of DOE's waste characterization and remediation efforts and to obtain baseline data on the content of the storage tank interiors as well as data on changes in the tank contents and levels brought about by waste remediation steps. Initially targeted for deployment at the Hanford Washington site, the TMS is designed to be a self-contained, compact, reconfigurable system that is capable of providing rapid, variable-resolution mapping information in poorly characterized workspaces with a minimum of operator intervention.

  1. Attribute-Based Digital Signature System

    NARCIS (Netherlands)

    Ibraimi, L.; Asim, Muhammad; Petkovic, M.

    2011-01-01

    An attribute-based digital signature system comprises a signature generation unit (1) for signing a message (m) by generating a signature (s) based on a user secret key (SK) associated with a set of user attributes, wherein the signature generation unit (1) is arranged for combining the user secret

  2. Digital BPM Systems for Hadron Accelerators

    CERN Document Server

    Belleman, J; Kasprowicz, G; Raich, U

    2009-01-01

    The CERN Proton Synchrotron has been fitted with a new trajectory measurement system (TMS). Analogue signals from forty beam position monitors are digitized at 125MS/s, and then further treated entirely in the digital domain to derive the positions of all individual particle bunches on the fly. Large FPGAs handle all digital processing. The system fits in fourteen plug-in modules distributed over three half-width cPCI crates. Data are stored in circular buffers of large enough size to keep a fewseconds-worth of position data. Multiple clients can then request selected portions of the data, possibly representing many thousands of consecutive turns, for display on operator consoles. The system uses digital phase-locked loops to derive its beamlocked timing reference. Programmable state machines, driven by accelerator timing pulses and information from the accelerator control system, direct the order of operations. The cPCI crates are connected to a standard Linux computer by means of a private Gigabit Ethernet ...

  3. Radiological emergency assessment of local decision support system

    International Nuclear Information System (INIS)

    Breznik, B.; Kusar, A.; Boznar, M.Z.; Mlakar, P.

    2003-01-01

    Local decision support system has been developed based on the needs of Krsko Nuclear Power Plant for quick dose projection and it is one of important features required for proposal of intervention before actual release may occur. Radiological emergency assessment in the case of nuclear accident is based on plant status analysis, radiation monitoring data and on prediction of release of radioactive sources to the environment. There are possibilities to use automatic features to predict release source term and manual options for selection of release parameters. Advanced environmental modelling is used for assessment of atmospheric dispersion of radioactive contamination in the environment. (author)

  4. Central nervous system tumors: Radiologic pathologic correlation and diagnostic approach

    Directory of Open Access Journals (Sweden)

    Ishita Pant

    2015-01-01

    Full Text Available Objective: This study was conducted to formulate location-wise radiologic diagnostic algorithms and assess their concordance with the final histopathological diagnosis so as to evaluate their utility in a rural setting where only basic facilities are available. Materials and Methods: A retrospective analysis to assess the concordance of radiology (primarily MRI with final histopathology report was done. Based on the most common incidence of tumor location and basic radiology findings, diagnostic algorithms were prepared. Results: For supratentorial intraaxial parenchymal location concordance was seen in all high-grade astrocytomas, low- and high-grade oligodendrogliomas, metastatic tumors, primitive neuroectodermal tumors, high-grade ependymomas, neuronal and mixed neuro-glial tumors and tumors of hematopoietic system. Lowest concordance was seen in low-grade astrocytomas. In the supratentorial intraaxial ventricular location, agreement was observed in choroid plexus tumors, ependymomas, low-grade astrocytomas and meningiomas; in the supratentorial extraaxial location, except for the lack of concordance in the only case of metastatic tumor, concordance was observed in meningeal tumors, tumors of the sellar region, tumors of cranial and paraspinal nerves; the infratentorial intraaxial parenchymal location showed agreement in low- as well as high-grade astrocytomas, metastatic tumors, high-grade ependymoma, embryonal tumors and hematopoietic tumors; in the infratentorial intraaxial ventricular location, except for the lack of concordance in one case of low-grade astrocytoma and two cases of medulloblastomas, agreement was observed in low- and high-grade ependymoma; infratentorial extraaxial tumors showed complete agreement in all tumors of cranial and paraspinal nerves, meningiomas, and hematopoietic tumors. Conclusion: A location-based approach to central nervous system (CNS tumors is helpful in establishing an appropriate differential diagnosis.

  5. SITE GENERATED RADIOLOGICAL WASTE HANDLING SYSTEM DESCRIPTION DOCUMENT

    Energy Technology Data Exchange (ETDEWEB)

    S. C. Khamankar

    2000-06-20

    The Site Generated Radiological Waste Handling System handles radioactive waste products that are generated at the geologic repository operations area. The waste is collected, treated if required, packaged for shipment, and shipped to a disposal site. Waste streams include low-level waste (LLW) in solid and liquid forms, as-well-as mixed waste that contains hazardous and radioactive constituents. Liquid LLW is segregated into two streams, non-recyclable and recyclable. The non-recyclable stream may contain detergents or other non-hazardous cleaning agents and is packaged for shipment. The recyclable stream is treated to recycle a large portion of the water while the remaining concentrated waste is packaged for shipment; this greatly reduces the volume of waste requiring disposal. There will be no liquid LLW discharge. Solid LLW consists of wet solids such as ion exchange resins and filter cartridges, as-well-as dry active waste such as tools, protective clothing, and poly bags. Solids will be sorted, volume reduced, and packaged for shipment. The generation of mixed waste at the Monitored Geologic Repository (MGR) is not planned; however, if it does come into existence, it will be collected and packaged for disposal at its point of occurrence, temporarily staged, then shipped to government-approved off-site facilities for disposal. The Site Generated Radiological Waste Handling System has equipment located in both the Waste Treatment Building (WTB) and in the Waste Handling Building (WHB). All types of liquid and solid LLW are processed in the WTB, while wet solid waste from the Pool Water Treatment and Cooling System is packaged where received in the WHB. There is no installed hardware for mixed waste. The Site Generated Radiological Waste Handling System receives waste from locations where water is used for decontamination functions. In most cases the water is piped back to the WTB for processing. The WTB and WHB provide staging areas for storing and shipping LLW

  6. SITE GENERATED RADIOLOGICAL WASTE HANDLING SYSTEM DESCRIPTION DOCUMENT

    International Nuclear Information System (INIS)

    S. C. Khamankar

    2000-01-01

    The Site Generated Radiological Waste Handling System handles radioactive waste products that are generated at the geologic repository operations area. The waste is collected, treated if required, packaged for shipment, and shipped to a disposal site. Waste streams include low-level waste (LLW) in solid and liquid forms, as-well-as mixed waste that contains hazardous and radioactive constituents. Liquid LLW is segregated into two streams, non-recyclable and recyclable. The non-recyclable stream may contain detergents or other non-hazardous cleaning agents and is packaged for shipment. The recyclable stream is treated to recycle a large portion of the water while the remaining concentrated waste is packaged for shipment; this greatly reduces the volume of waste requiring disposal. There will be no liquid LLW discharge. Solid LLW consists of wet solids such as ion exchange resins and filter cartridges, as-well-as dry active waste such as tools, protective clothing, and poly bags. Solids will be sorted, volume reduced, and packaged for shipment. The generation of mixed waste at the Monitored Geologic Repository (MGR) is not planned; however, if it does come into existence, it will be collected and packaged for disposal at its point of occurrence, temporarily staged, then shipped to government-approved off-site facilities for disposal. The Site Generated Radiological Waste Handling System has equipment located in both the Waste Treatment Building (WTB) and in the Waste Handling Building (WHB). All types of liquid and solid LLW are processed in the WTB, while wet solid waste from the Pool Water Treatment and Cooling System is packaged where received in the WHB. There is no installed hardware for mixed waste. The Site Generated Radiological Waste Handling System receives waste from locations where water is used for decontamination functions. In most cases the water is piped back to the WTB for processing. The WTB and WHB provide staging areas for storing and shipping LLW

  7. Radiology Reporting System Data Exchange With the Electronic Health Record System: A Case Study in Iran.

    Science.gov (United States)

    Ahmadi, Maryam; Ghazisaeidi, Marjan; Bashiri, Azadeh

    2015-03-18

    In order to better designing of electronic health record system in Iran, integration of health information systems based on a common language must be done to interpret and exchange this information with this system is required. This study provides a conceptual model of radiology reporting system using unified modeling language. The proposed model can solve the problem of integration this information system with the electronic health record system. By using this model and design its service based, easily connect to electronic health record in Iran and facilitate transfer radiology report data. This is a cross-sectional study that was conducted in 2013. The study population was 22 experts that working at the Imaging Center in Imam Khomeini Hospital in Tehran and the sample was accorded with the community. Research tool was a questionnaire that prepared by the researcher to determine the information requirements. Content validity and test-retest method was used to measure validity and reliability of questioner respectively. Data analyzed with average index, using SPSS. Also Visual Paradigm software was used to design a conceptual model. Based on the requirements assessment of experts and related texts, administrative, demographic and clinical data and radiological examination results and if the anesthesia procedure performed, anesthesia data suggested as minimum data set for radiology report and based it class diagram designed. Also by identifying radiology reporting system process, use case was drawn. According to the application of radiology reports in electronic health record system for diagnosing and managing of clinical problem of the patient, with providing the conceptual Model for radiology reporting system; in order to systematically design it, the problem of data sharing between these systems and electronic health records system would eliminate.

  8. Quality control of the interpretation monitors of digital radiological images; Controle de qualidade dos monitores de interpretacao de imagens radiologicas digitais: uma revisao

    Energy Technology Data Exchange (ETDEWEB)

    Favero, Mariana S.; Goulart, Adriano Oliveira S., E-mail: mariana@phymed.com.br [PhyMED - Consultores em Fisica Medica e Radioprotecao Ltda, Porto Alegre, RS (Brazil)

    2016-07-01

    The performance monitors has great importance in image quality of digital radiographic systems. In environments without films, it became necessary to implement acceptance testing and quality control monitors used for interpretation of medical images. The monitors dedicated to radiodiagnostic should provide information that represent slight differences in x-ray attenuation or minor differences in some anatomical region of interest. This should also result in small differences in luminance of an image represented. Factors affecting the quality of medical imaging are contrast, noise, resolution, artifacts and distortions. Therefore, a monitor must have specific characteristics, making it possible for the observer to carry out an assessment that leads to better diagnosis. Based on the need to evaluate diagnostic monitors in various radiological applications, this paper presents a summary for implementation and standardization of tests that are recommended by the publication AAPM Report 03. (author)

  9. Digital detection systems for projection radiography

    International Nuclear Information System (INIS)

    Schulz, R.F.

    2001-01-01

    This article gives a survey of digital X-ray detection systems for projection radiography. The different principles are compared and some general characteristics are derived. The basic conversion mechanisms in the absorption layers are described. The basic principles of solid state X-ray detectors and their general characteristics are elucidated as well as some similarities with detectors for computed tomography. Some important application and system aspects are considered. An outlook on further possible developments in this field is given. (orig.) [de

  10. Adaption of the Quality Criteria Concept to Digital Radiology (invited paper)

    International Nuclear Information System (INIS)

    Busch, H.P.; Jaschke, W.

    1998-01-01

    In recent years conventional film-screen radiography has been more and more replaced by digital techniques like 'Digital Image Intensifier Radiography' and 'Digital Storage Phosphor (Selen) Radiography'. These new digital imaging methods can be used for all areas of radiography except mammography. Digital radiography offers the advantage of additional diagnostic information, digital image format, lower radiation risk to the patient and a favourable cost/benefit relation. With digital techniques, dose can be varied over a wide range without losing diagnostic information. Thus, dose can be reduced in comparison to film-screen radiography. Inadequate technique can, in certain applications, however, lead to a significant increase of dose. Therefore, special reference dose values have to be established and controlled continuously. Different possibilities of pre- and post-processing make the evaluation of image quality of digital technique more complex compared with conventional film-screen radiography. New parameters like signal to noise ratio are more appropriate in assessing image quality. However, in daily routine well known parameters like spatial resolution, contrast detectability and dose can be more easily used for the assessment of image quality of the whole imaging chain including image processing and documentation. Special guidelines for digital radiography are necessary to guarantee high image quality and to avoid overexposure and misdiagnoses. These guidelines should be based on the Quality Criteria Concept of the EC. They should include criteria for the detectability of specific anatomic details, technical parameters for good radiographic technique and imaging performance and reference dose values. Assessment of image quality by suitable phantoms and constancy testing are prerequisites for quality assurance. The activities of an European quality criteria working group in the 'Concerted Action Programme' are focused on these subjects. (author)

  11. Radiological information systems: improvements in service, economy, and quality control?

    International Nuclear Information System (INIS)

    Gross-Fengels, W.; Weber, M.

    1997-01-01

    By means of complete service control and standardized accounting processes, radiological information systems clearly contribute to improved results. They provide the prerequisites for the establishment of expanded networks and allow comprisons with comparable institutions. The quality of patient care can be improved since, for example, the production time from referral to finished result becomes shorter. Direct access to patient and findings data from several positions is possible. Preliminary results can be viewed immediately. The patient's history is accessible to authorized users at all times. The exact reproducibility and assignment of services leads to more clarity. By means of the information available form RIS, rapid adaptive processes can be undertaken. The system assists the to fulfill the requirements of health regulations. The above-mentioned relationships demonstrate that the EDP systems are well accepted by physicians, medical assistants, and administrators and represent an indispensable aid for solving problems. (orig.) [de

  12. Lean Management Systems in Radiology: Elements for Success.

    Science.gov (United States)

    Schultz, Stacy R; Ruter, Royce L; Tibor, Laura C

    2016-01-01

    This article is a review of the literature on Lean and Lean Management Systems and how they have been implemented in healthcare organizations and particularly in radiology departments. The review focuses on the elements required for a successful implementation of Lean by applying the principles of a Lean Management System instead of a Lean tools-only approach. This review shares the successes and failures from healthcare organizations' efforts to improve the quality and safety of the services they provide. There are a limited number of healthcare organizations in the literature who have shared their experiences and additional research is necessary to determine whether a Lean Management System is a viable alternative to the current management structure in healthcare.

  13. A digital video tracking system

    Science.gov (United States)

    Giles, M. K.

    1980-01-01

    The Real-Time Videotheodolite (RTV) was developed in connection with the requirement to replace film as a recording medium to obtain the real-time location of an object in the field-of-view (FOV) of a long focal length theodolite. Design philosophy called for a system capable of discriminatory judgment in identifying the object to be tracked with 60 independent observations per second, capable of locating the center of mass of the object projection on the image plane within about 2% of the FOV in rapidly changing background/foreground situations, and able to generate a predicted observation angle for the next observation. A description is given of a number of subsystems of the RTV, taking into account the processor configuration, the video processor, the projection processor, the tracker processor, the control processor, and the optics interface and imaging subsystem.

  14. Essential Requirements for Digital Annotation Systems

    Directory of Open Access Journals (Sweden)

    ADRIANO, C. M.

    2012-06-01

    Full Text Available Digital annotation systems are usually based on partial scenarios and arbitrary requirements. Accidental and essential characteristics are usually mixed in non explicit models. Documents and annotations are linked together accidentally according to the current technology, allowing for the development of disposable prototypes, but not to the support of non-functional requirements such as extensibility, robustness and interactivity. In this paper we perform a careful analysis on the concept of annotation, studying the scenarios supported by digital annotation tools. We also derived essential requirements based on a classification of annotation systems applied to existing tools. The analysis performed and the proposed classification can be applied and extended to other type of collaborative systems.

  15. Evaluating phantom image quality parameters to optimise patient radiation dose in dental digital radiology.

    Science.gov (United States)

    Gonzalez, Luciano; Vano, Eliseo; Fernandez, Ramon; Ziraldo, Viviana; Delgado, Jaime; Delgado, Victor; Moro, Javier; Ubeda, Carlos

    2012-08-01

    Our objective was to obtain images of a predictable level of quality using an intraoral X-ray system with digital imaging, avoiding patient overexposure. A polymethylmethacrylate (PMMA) physical test phantom was imaged at different exposure times and at various PMMA thicknesses using a dental imaging coupled charge device. Two identical regions of interest (ROIs) were chosen in every image file, and quality was numerically evaluated by measuring high-contrast spatial resolutions, low-contrast thresholds and signal-to-noise ratios. In addition, three practitioners proposed personal quality scores by image inspection. Numerical contents in the ROIs, related to the image quality, were plotted against exposure time. From here, a simple expression linking the exposure time with the thickness to obtain images of comparable quality was deduced. As a result, the optimum exposure time for imaging with a predictable level of quality can be inferred. The potential effect could imply savings above 1000 man Sv, roughly 20 % of the collective dose due to dental imaging, over a population of 1540 millions.

  16. Evaluation of the detector response function digital conventional radiology; Evaluacion de la funcion de respuesta del detector degital en radiologia convencional. Obtencion de la funcion de referencia

    Energy Technology Data Exchange (ETDEWEB)

    Arino Gil, A.; Hernandez Rodriguez, J.; Mateos Salvador, P.; Rodriguez Lopez, B.; Font Gelabert, J. C.

    2013-07-01

    The objective of this work is to obtain the response function that relates the air kerma at the entrance of the detector and pixel value, for a series of digital detectors of conventional Radiology model Optimus DigitalDiagnost Philips () and 6000 Definium General Electric. From the set of measurements is obtained a response function for each reference type of detector, and compared with those published in the literature for these teams. (Author)

  17. HL7 and DICOM based integration of radiology departments with healthcare enterprise information systems.

    Science.gov (United States)

    Blazona, Bojan; Koncar, Miroslav

    2007-12-01

    Integration based on open standards, in order to achieve communication and information interoperability, is one of the key aspects of modern health care information systems. However, this requirement represents one of the major challenges for the Information and Communication Technology (ICT) solutions, as systems today use diverse technologies, proprietary protocols and communication standards which are often not interoperable. One of the main producers of clinical information in healthcare settings represent Radiology Information Systems (RIS) that communicate using widely adopted DICOM (Digital Imaging and COmmunications in Medicine) standard, but in very few cases can efficiently integrate information of interest with other systems. In this context we identified HL7 standard as the world's leading medical ICT standard that is envisioned to provide the umbrella for medical data semantic interoperability, which amongst other things represents the cornerstone for the Croatia's National Integrated Healthcare Information System (IHCIS). The aim was to explore the ability to integrate and exchange RIS originated data with Hospital Information Systems based on HL7's CDA (Clinical Document Architecture) standard. We explored the ability of HL7 CDA specifications and methodology to address the need of RIS integration HL7 based healthcare information systems. We introduced the use of WADO service interconnection to IHCIS and finally CDA rendering in widely used Internet explorers. The outcome of our pilot work proves our original assumption of HL7 standard being able to adopt radiology data into the integrated healthcare systems. Uniform DICOM to CDA translation scripts and business processes within IHCIS is desired and cost effective regarding to use of supporting IHCIS services aligned to SOA.

  18. Process simulation in digital camera system

    Science.gov (United States)

    Toadere, Florin

    2012-06-01

    The goal of this paper is to simulate the functionality of a digital camera system. The simulations cover the conversion from light to numerical signal and the color processing and rendering. We consider the image acquisition system to be linear shift invariant and axial. The light propagation is orthogonal to the system. We use a spectral image processing algorithm in order to simulate the radiometric properties of a digital camera. In the algorithm we take into consideration the transmittances of the: light source, lenses, filters and the quantum efficiency of a CMOS (complementary metal oxide semiconductor) sensor. The optical part is characterized by a multiple convolution between the different points spread functions of the optical components. We use a Cooke triplet, the aperture, the light fall off and the optical part of the CMOS sensor. The electrical part consists of the: Bayer sampling, interpolation, signal to noise ratio, dynamic range, analog to digital conversion and JPG compression. We reconstruct the noisy blurred image by blending different light exposed images in order to reduce the photon shot noise, also we filter the fixed pattern noise and we sharpen the image. Then we have the color processing blocks: white balancing, color correction, gamma correction, and conversion from XYZ color space to RGB color space. For the reproduction of color we use an OLED (organic light emitting diode) monitor. The analysis can be useful to assist students and engineers in image quality evaluation and imaging system design. Many other configurations of blocks can be used in our analysis.

  19. Current radiology. Volume 5

    International Nuclear Information System (INIS)

    Wilson, G.H.; Hanafee, W.N.

    1984-01-01

    This book contains 10 selections. They are: Nuclear Magnetic Resonance Imaging, Interventional Vascular Radiology, Genitourinary Radiology, Skeletal Radiology, Digital Subtraction Angiography, Neuroradiology, Computed Tomographic Evaluation of Degenerative Diseases of the Lumbar Spine, The Lung, Otolaringology and Opthalmology, and Pediatric Radiology: Cranial, Facial, Cervical, Vertebral, and Appendicular

  20. Options for Next Generation Digital Acquisition Systems

    CERN Document Server

    Boccardi, A

    2011-01-01

    Digital acquisition system designers have an always increasing number of options in terms of bus standards and digital signal processing hardware among which to choose. This allows for high flexibility but also opens the door to a proliferation of different architectures, potentially limiting the reusability and the design synergies among the various instrumentation groups. This contribution illustrates the design trends in some of the major institutes around the world with design examples including VME, PCI and TCA based modular systems using AMC and/or FMC mezzanines. Some examples of FPGA design practices aimed at increasing reusability of code will be mentioned together with some of the tools already available to designers to improve the information exchange and collaboration, like the Open Hardware Repository project.

  1. Modems for emerging digital cellular-mobile radio system

    Science.gov (United States)

    Feher, Kamilo

    1991-01-01

    Digital modem techniques for emerging digital cellular telecommunications-mobile radio system applications are described and analyzed. In particular, theoretical performance, experimental results, principles of operation, and various architectures of pi/4-QPSK (pi/4-shifted coherent or differential QPSK) modems for second-generation US digital cellular radio system applications are presented. The spectral/power efficiency and performance of the pi/4-QPSK modems (American and Japanese digital cellular emerging standards) are studied and briefly compared to GMSK (Gaussian minimum-shift keying) modems (proposed for European DECT and GSM cellular standards). Improved filtering strategies and digital pilot-aided (digital channel sounding) techniques are also considered for pi/4-QPSK and other digital modems. These techniques could significantly improve the performance of digital cellular and other digital land mobile and satellite mobile radio systems. More spectrally efficient modem trends for future cellular/mobile (land mobile) and satellite communication systems applications are also highlighted.

  2. Increasing clinical relevance in oral radiology: Benefits and challenges when implementing digital assessment.

    Science.gov (United States)

    de Lange, T; Møystad, A; Torgersen, G R

    2018-02-13

    The aims of the study were to investigate benefits and challenges in implementing a digital examination and study the clinical relevance of the digital examination in relation to clinical training and practice. The study was based on semi-structured focus-group interviews from two distinct student populations (2016 and 2017) in a bachelor programme in dental hygiene. In addition, conversational data from a plenary discussion from the whole second student population (2017) were collected and analysed. The data were approached on basis of content analysis. A benefit experienced in the digital examination was the ease in typing and editing answers on the computer. This suggests an increased effectiveness in computer-based compared to analogue examinations. An additional advantage was the experienced relevance of the examination related to the clinic. This finding refers not only to the digital presentations of images, but also to the entire setting in the clinic and dental practice. The limitations reported by the students were non-optimal viewing conditions for presenting radiographic images and difficulties in obtaining an overview of the assignments compared to paper-based examinations due to the linear digital examination format. The last finding on lacking overview revealed an influence on student performances which should be taken seriously in designing digital examinations. In conclusion, the digital layout increases efficiency and clinical relevance of examinations to a certain extent. Obstacles were found in limitations related to image presentation and lack of overview of the examination. The latter challenge raises questions related to developing suitable assessment software. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Multichannel Digital Emulator of Radiation Detection Systems

    International Nuclear Information System (INIS)

    Abba, A.; Caponio, F.; Geraci, A.

    2013-06-01

    A digital system for emulating in real time signals from generic setups for radiation detection is presented. The instrument is not a pulse generator of recorded shapes but a synthesizer of random pulses compliant to programmable statistics for energy and occurrence time. Completely programmable procedures for emulation of noise, disturbances and reference level variation can be implemented. The instrument has been realized and fully tested. (authors)

  4. Technological Improvements for Digital Fire Control Systems

    Science.gov (United States)

    2017-09-30

    Final Technical Status Report For DOTC-12-01-INIT061 Technological Improvements for Digital Fire Control Systems Reporting Period: 30 Sep...accuracy and responsiveness to call for fire. These prototypes shall be more cost effective, sustainable , use a higher percentage of alternative...of the quad charts and provide DOTC with sufficient initiative information, the Quarterly Report must be supplemented with data described below

  5. Control theory of digitally networked dynamic systems

    CERN Document Server

    Lunze, Jan

    2013-01-01

    The book gives an introduction to networked control systems and describes new modeling paradigms, analysis methods for event-driven, digitally networked systems, and design methods for distributed estimation and control. Networked model predictive control is developed as a means to tolerate time delays and packet loss brought about by the communication network. In event-based control the traditional periodic sampling is replaced by state-dependent triggering schemes. Novel methods for multi-agent systems ensure complete or clustered synchrony of agents with identical or with individual dynamic

  6. Lessons learned in digital upgrade projects digital control system implementation at US nuclear power stations

    International Nuclear Information System (INIS)

    Kelley, S.; Bolian, T. W.

    2006-01-01

    AREVA NP has gained significant experience during the past five years in digital upgrades at operating nuclear power stations in the US. Plants are seeking modernization with digital technology to address obsolescence, spare parts availability, vendor support, increasing age-related failures and diminished reliability. New systems offer improved reliability and functionality, and decreased maintenance requirements. Significant lessons learned have been identified relating to the areas of licensing, equipment qualification, software quality assurance and other topics specific to digital controls. Digital control systems have been installed in non safety-related control applications at many utilities within the last 15 years. There have also been a few replacements of small safety-related systems with digital technology. Digital control systems are proving to be reliable, accurate, and easy to maintain. Digital technology is gaining acceptance and momentum with both utilities and regulatory agencies based upon the successes of these installations. Also, new plants are being designed with integrated digital control systems. To support plant life extension and address obsolescence of critical components, utilities are beginning to install digital technology for primary safety-system replacement. AREVA NP analyzed operating experience and lessons learned from its own digital upgrade projects as well as industry-wide experience to identify key issues that should be considered when implementing digital controls in nuclear power stations

  7. Radiologic findings in late-onset systemic lupus erythematosus

    International Nuclear Information System (INIS)

    Braunstein, E.M.; Weissman, B.N.; Sosman, J.L.; Schur, P.H.

    1983-01-01

    Systemic lupus erythematosus in the elderly has a different clinical and serologic course from that in young patients. Radiographic findings in patients in whom the diagnosis was made after age 50 were compared with findings in younger patients to see if the radiologic patterns are also different. The only significant radiographic difference between the two groups was that the older group had a greater incidence of soft-tissue swelling of the hands and wrists (p < 0.001). There was no significant difference in osteopenia, erosion, soft-tissue calcification, alignment abnormalities, or intrathoracic findings. Of 24 patients over age 50, two developed lymphoma and another developed multiple myeloma. The data agree with clinical observations that there is a higher incidence of arthritis in late-onset lupus, but clinical findings of increased incidence of pleuropericardial disease are not confirmed radiographically. The coincidence of hematologic malignancy with late-onset lupus in this series is noteworthy

  8. The Rise of Digital Multimedia Systems

    Directory of Open Access Journals (Sweden)

    Ross Gibson

    2013-08-01

    Full Text Available With this essay, I want to understand why interactive and relational media forms have become so ubiquitous so quickly. Comparing the nexus of cinema and nationalism with the contemporary dyad of digital media and transnationalism (or globalisation, we can ask whether digital multimedia systems have arisen to reflect and impel our contemporary psychic and social conditions. Because multimedia rarely gets ‘locked-off’, its component elements can always be pulled apart, sent back to their databases and then instantaneously rearranged into newly iterated federations. In this respect it is like our unstable contemporary lives, so buffeted with ever-altering values, opportunities, anxieties and obligations all upwelling because of globalisation, migration and multiculturalism.

  9. Large-scale digitizer system, analog converters

    International Nuclear Information System (INIS)

    Althaus, R.F.; Lee, K.L.; Kirsten, F.A.; Wagner, L.J.

    1976-10-01

    Analog to digital converter circuits that are based on the sharing of common resources, including those which are critical to the linearity and stability of the individual channels, are described. Simplicity of circuit composition is valued over other more costly approaches. These are intended to be applied in a large-scale processing and digitizing system for use with high-energy physics detectors such as drift-chambers or phototube-scintillator arrays. Signal distribution techniques are of paramount importance in maintaining adequate signal-to-noise ratio. Noise in both amplitude and time-jitter senses is held sufficiently low so that conversions with 10-bit charge resolution and 12-bit time resolution are achieved

  10. Digital processing data communication systems (bus systems). Digitale Prozessdaten-Kommunikations-Systeme (Bus Systeme)

    Energy Technology Data Exchange (ETDEWEB)

    Fleck, K

    1980-01-01

    After an introduction to the technology of digital processing data communication systems there are the following chapters: digital communication of processing data in automation technology, the technology of biserial communication, the implementaiton of a bus system, the data transmission of the TDC-2000 system of Honeywell's and the process bus CS 275 in the automation system TELEPERM M of Siemens AG.

  11. Automated hazard analysis of digital control systems

    International Nuclear Information System (INIS)

    Garrett, Chris J.; Apostolakis, George E.

    2002-01-01

    Digital instrumentation and control (I and C) systems can provide important benefits in many safety-critical applications, but they can also introduce potential new failure modes that can affect safety. Unlike electro-mechanical systems, whose failure modes are fairly well understood and which can often be built to fail in a particular way, software errors are very unpredictable. There is virtually no nontrivial software that will function as expected under all conditions. Consequently, there is a great deal of concern about whether there is a sufficient basis on which to resolve questions about safety. In this paper, an approach for validating the safety requirements of digital I and C systems is developed which uses the Dynamic Flowgraph Methodology to conduct automated hazard analyses. The prime implicants of these analyses can be used to identify unknown system hazards, prioritize the disposition of known system hazards, and guide lower-level design decisions to either eliminate or mitigate known hazards. In a case study involving a space-based reactor control system, the method succeeded in identifying an unknown failure mechanism

  12. Advanced optical manufacturing digital integrated system

    Science.gov (United States)

    Tao, Yizheng; Li, Xinglan; Li, Wei; Tang, Dingyong

    2012-10-01

    It is necessarily to adapt development of advanced optical manufacturing technology with modern science technology development. To solved these problems which low of ration, ratio of finished product, repetition, consistent in big size and high precision in advanced optical component manufacturing. Applied business driven and method of Rational Unified Process, this paper has researched advanced optical manufacturing process flow, requirement of Advanced Optical Manufacturing integrated System, and put forward architecture and key technology of it. Designed Optical component core and Manufacturing process driven of Advanced Optical Manufacturing Digital Integrated System. the result displayed effective well, realized dynamic planning Manufacturing process, information integration improved ratio of production manufactory.

  13. Transceiver and system design for digital communications

    CERN Document Server

    Bullock, Scott

    2009-01-01

    Now in a 3rd edition, this successful book provides an intuitive approach to transceiver design, allowing a broad spectrum of readers to understand the topics clearly. It covers a wide range of data link communication design techniques, including link budgets, dynamic range and system analysis of receivers and transmitters used in data link communications, digital modulation and demodulation techniques of phase-shift keyed and frequency hopped spread spectrum systems using phase diagrams, multipath, gain control, an intuitive approach to probability, jamming reduction method using various adap

  14. Development of digital safety system logic and control

    International Nuclear Information System (INIS)

    Nishikawa, H.; Sakamoto, H.

    1995-01-01

    Advanced-BWR (ABWR) uses total digital control and instrumentation (C and I) system. In particular, ABWR adopts a newly developed safety system using advanced digital technology. In the presentation the digital safety system design, manufacturing and factory validation test method are shortly overviewed. The digital safety system consists of micro-processor based digital controllers, data and information transmission by optical fibers and human-machine interface using color flat displays. This new developed safety system meet the nuclear safety requirements such as high reliability, independence of divisions, operability and maintainability. (2 refs., 4 figs., 1 tab.)

  15. Radiological assessment of breast density by visual classification (BI-RADS) compared to automated volumetric digital software (Quantra): implications for clinical practice.

    Science.gov (United States)

    Regini, Elisa; Mariscotti, Giovanna; Durando, Manuela; Ghione, Gianluca; Luparia, Andrea; Campanino, Pier Paolo; Bianchi, Caterina Chiara; Bergamasco, Laura; Fonio, Paolo; Gandini, Giovanni

    2014-10-01

    This study was done to assess breast density on digital mammography and digital breast tomosynthesis according to the visual Breast Imaging Reporting and Data System (BI-RADS) classification, to compare visual assessment with Quantra software for automated density measurement, and to establish the role of the software in clinical practice. We analysed 200 digital mammograms performed in 2D and 3D modality, 100 of which positive for breast cancer and 100 negative. Radiological density was assessed with the BI-RADS classification; a Quantra density cut-off value was sought on the 2D images only to discriminate between BI-RADS categories 1-2 and BI-RADS 3-4. Breast density was correlated with age, use of hormone therapy, and increased risk of disease. The agreement between the 2D and 3D assessments of BI-RADS density was high (K 0.96). A cut-off value of 21% is that which allows us to best discriminate between BI-RADS categories 1-2 and 3-4. Breast density was negatively correlated to age (r = -0.44) and positively to use of hormone therapy (p = 0.0004). Quantra density was higher in breasts with cancer than in healthy breasts. There is no clear difference between the visual assessments of density on 2D and 3D images. Use of the automated system requires the adoption of a cut-off value (set at 21%) to effectively discriminate BI-RADS 1-2 and 3-4, and could be useful in clinical practice.

  16. A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Daegoo

    International Nuclear Information System (INIS)

    Jo, Gwang Ho; Kang, Yeopng Han; Kim, Bu Sun

    2008-01-01

    Digital imaging for general radiography has many advantages over the film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider range means that acceptable images may by acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose. We investigated the actual exposure dose conditions on general radiography and a questionnaire survey was conducted with radiotechnologiest at medical institutions using digital radiology system. As a results, the dose of exposure was not controlled with patient's figure and dose optimization but was controlled by worker's convenience and image quality. Radio-technologiests often set up the exposure dose regardless of patient figure and body part to be examined. Many organizations, such as the International Commission on Radiological Protection, recommend to keep the dose as low as possible. In addition, they strongly recommend to keep the optimal but minimal dosage by proper training programs and constant quality control, including frequent patient dose evaluations and education.

  17. Prerequisites for the introduction of computer-assisted radiological systems of organization

    International Nuclear Information System (INIS)

    Timmermann, U.; Jacob, A.

    1988-01-01

    This paper describes the steps necessary for the introduction of a radiological information system (RIS) for organizational and work-flow support within a large radiology department. The authors experience with a pilot trial of a system purchased and adapted to departmental needs is reported. (orig.) [de

  18. Data compression systems for home-use digital video recording

    NARCIS (Netherlands)

    With, de P.H.N.; Breeuwer, M.; van Grinsven, P.A.M.

    1992-01-01

    The authors focus on image data compression techniques for digital recording. Image coding for storage equipment covers a large variety of systems because the applications differ considerably in nature. Video coding systems suitable for digital TV and HDTV recording and digital electronic still

  19. Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification.

    Science.gov (United States)

    Wang, Yingbing; Ebuoma, Lilian; Saksena, Mansi; Liu, Bob; Specht, Michelle; Rafferty, Elizabeth

    2014-08-01

    Use of mobile digital specimen radiography systems expedites intraoperative verification of excised breast specimens. The purpose of this study was to evaluate the performance of a such a system for verifying targets. A retrospective review included 100 consecutive pairs of breast specimen radiographs. Specimens were imaged in the operating room with a mobile digital specimen radiography system and then with a conventional digital mammography system in the radiology department. Two expert reviewers independently scored each image for image quality on a 3-point scale and confidence in target visualization on a 5-point scale. A target was considered confidently verified only if both reviewers declared the target to be confidently detected. The 100 specimens contained a total of 174 targets, including 85 clips (49%), 53 calcifications (30%), 35 masses (20%), and one architectural distortion (1%). Although a significantly higher percentage of mobile digital specimen radiographs were considered poor quality by at least one reviewer (25%) compared with conventional digital mammograms (1%), 169 targets (97%), were confidently verified with mobile specimen radiography; 172 targets (98%) were verified with conventional digital mammography. Three faint masses were not confidently verified with mobile specimen radiography, and conventional digital mammography was needed for confirmation. One faint mass and one architectural distortion were not confidently verified with either method. Mobile digital specimen radiography allows high diagnostic confidence for verification of target excision in breast specimens across target types, despite lower image quality. Substituting this modality for conventional digital mammography can eliminate delays associated with specimen transport, potentially decreasing surgical duration and increasing operating room throughput.

  20. Simulation of Wireless Digital Communication Systems

    Directory of Open Access Journals (Sweden)

    A. Mohammed

    2004-12-01

    Full Text Available Due to the explosive demands for high speed wireless services, suchas wireless Internet, email and cellular video conferencing, digitalwireless communications has become one of the most exciting researchtopics in electrical and electronic engineering field. The never-endingdemand for such personal and multimedia services, however, demandstechnologies operating at higher data rates and broader bandwidths. Inaddition, the complexity of wireless communication and signalprocessing systems has grown considerably during the past decade.Therefore, powerful computer­aided techniques are required for theprocess of modeling, designing, analyzing and evaluating theperformance of digital wireless communication systems. In this paper wediscuss the basic propagation mechanisms affecting the performance ofwireless communication systems, and present a simple, powerful andefficient way to simulate digital wireless communication systems usingMatlab. The simulated results are compared with the theoreticalanalysis to validate the simulator. The simulator is useful inevaluating the performance of wireless multimedia services and theassociated signal processing structures and algorithms for current andnext generation wireless mobile communication systems.

  1. Board's system of publications. [National Radiological Protection Board

    Energy Technology Data Exchange (ETDEWEB)

    Gaines, M J [National Radiological Protection Board, Harwell (UK)

    1978-07-01

    The purpose of each of the several classes of publication issued by the National Radiological Protection Board is stated. The classes are: advice on standards for protection, emergency reference levels, technical reports, instrument evaluation reports, annual research and development reports, three-yearly reports on the work of the NRPB, miscellaneous specialist booklets, publications for the layman, radiological protection bulletin, information sheets, and brochures.

  2. Development of Shimadzu digital subtraction system

    International Nuclear Information System (INIS)

    Nishioka, Hiroyuki; Shibata, Koichi; Shimizu, Yasumitsu; Shibata, Kenji; Wani, Hidenobu

    1985-01-01

    Shimadzu has recently developed a digital subtraction system. It can perform intra-arterial digital subtraction angiography (DSA) using low concentration of contrast medium, or can visualize arteries with intravenuous injection. It can extremely reduce patient's pain in angiography. Image quality of DSA has been much improved by the development of high quality image amplifiers, improvement of signal-to-noise ratio of the x-ray television unit and the development of digital disk recorders. The peak-hold subtraction method that is now under clinical study presents images of blood vessels as the trace of the flow of contrast medium. The maximum-hold memory where the maximum value of the brightness in some period is stored for every picture element is subtracted from the minimum-hold memory where the minimum value is stored, and thus images of blood vessels can be obtained. Hardware of this method is rather simple and it is expected that the amount of contrast medium may be reduced or x-ray dose of the patient may be decreased. (author)

  3. Image quality in digital radiographic systems

    Directory of Open Access Journals (Sweden)

    Almeida Solange Maria de

    2003-01-01

    Full Text Available The aim of the present study was to evaluate the image quality of four direct digital radiographic systems. Radiographs were made of the maxillary central incisor and mandibular left molar regions of a dry skull, and an aluminum step-wedge. The X-ray generator operated at 10 mA, 60 and 70 kVp, and images were acquired with 3, 5, 8, 12, 24 and 48 exposure pulses. Six well-trained observers classified the images by means of scores from 1 to 3. Collected data were submitted to nonparametric statistical analysis using Fisher's exact test. Statistical analysis showed significant differences (p<0.01 in image quality with the four systems. Based on the results, it was possible to conclude that: 1 all of the digital systems presented good performance in producing acceptable images for diagnosis, if the exposures of the step-wedge and the maxillary central incisor region were made at 5 pulses, as well as at 8 pulses for the mandibular left molar region, selecting 60 or 70kVp; 2 higher percentages of acceptable images were obtained with the administration of lower radiation doses in CCD-sensors (charge-coupled device; 3 the Storage Phosphor systems produced acceptable images at a large range of exposure settings, that included low, intermediate and high radiation doses.

  4. In the digital era, architectural distortion remains a challenging radiological task

    International Nuclear Information System (INIS)

    Suleiman, W.I.; McEntee, M.F.; Lewis, S.J.; Rawashdeh, M.A.; Georgian-Smith, D.; Heard, R.; Tapia, K.; Brennan, P.C.

    2016-01-01

    Aim: To compare readers' performance in detecting architectural distortion (AD) compared with other breast cancer types using digital mammography. Materials and methods: Forty-one experienced breast screen readers (20 US and 21 Australian) were asked to read a single test set of 30 digitally acquired mammographic cases. Twenty cases had abnormal findings (10 with AD, 10 non-AD) and 10 cases were normal. Each reader was asked to locate and rate any abnormalities. Lesion and case-based performance was assessed. For each collection of readers (US; Australian; combined), jackknife free-response receiver operating characteristic (JAFROC), figure of merit (FOM), and inferred receiver operating characteristic (ROC), area under curve (Az) were calculated using JAFROC v.4.1 software. Readers' sensitivity, location sensitivity, JAFROC, FOM, ROC, Az scores were compared between cases groups using Wilcoxon's signed ranked test statistics. Results: For lesion-based analysis, significantly lower location sensitivity (p=0.001) was shown on AD cases compared with non-AD cases for all reader collections. The case-based analysis demonstrated significantly lower ROC Az values (p=0.02) for the first collection of readers, and lower sensitivity for the second collection of readers (p=0.04) and all-readers collection (p=0.008), for AD compared with non-AD cases. Conclusions: The current work demonstrates that AD remains a challenging task for readers, even in the digital era. - Highlights: • Architectural Distortion interpretation remains challenging for readers even with digital acquisition. • Significantly lower location sensitivity and sensitivity values for the AD were shown.

  5. Development of α - Al_2O_3:C films nanoparticulate for application in digital radiology

    International Nuclear Information System (INIS)

    Silva, Edna C.; Fontainha, Crissia C.; Ferraz, Wilmar B.; Faria, Luiz O.

    2011-01-01

    Phosphorescent ceramics are widely used in Ionizing radiation sensors. In nuclear applications, alpha-alumina doped with carbon (α-Al_2O_3: C) is most commonly used because of its excellent properties photoluminescent (OSL) and thermoluminescent (TL) in ionizing radiation detections. Another application of OSL and TL materials is the use in digital radiography. Recently, Computerized Radiography (CR) equipment, which use OSL materials, have been replacing the old X-ray devices. In this work we investigated the thermoluminescence of α-Al_2O_3 doped with different percentages of carbon, sintered in reducing atmospheres, in temperatures from 1300 to 1750 ° C. The results indicate that micro alumina doped with 0.5% of carbon and nano-alumina doped with 2% of carbon present TL signal of the order of 30 to 100 times the signal of the TLD-100, the most widely used TL dosimeter in the world. The results indicate that α-Al_2O_3: C nano-particulate has great potential for application in digital thermoluminescent radiography, because of its high TL response to radiation Ionization and the possibility of forming TL digital images with resolution increased by about 1000 times, depending on the size of the nanoparticles

  6. Development and application of portable mobile gamma spectrometry system (PMGSS) for realtime online radiological assessment

    International Nuclear Information System (INIS)

    Patil, S.S.; Padmanabhan, N.; Sharma, R.; Singh, R.; Pradeepkumar, K.S.

    2008-01-01

    A state of art mobile monitoring system is a prime requirement to combat the challenging radiological situations. In the event of any radiological/nuclear Emergencies an effective, realistic methodology of radiological measurements is an asset. In this context, a highly sensitive real-time online mobile monitoring system having features and provision to display the important parameters will be an essential tool in the course of radiological impact assessment. This paper, describes the efforts that has been made towards providing a useful Portable Mobile Gamma Spectrometry System (PMGSS) and developing applications so as to enhance its usefulness in quick radiological impact assessment and to initiate the proper countermeasures during any Nuclear/Radiological emergency situation in public domain. The system uses a NaI(Tl) detector, a global positioning system (GPS) and a laptop PC for storage, analysis and graphical representation of the acquired data. PMGSS is a highly sensitive, portable and reliable radiation monitoring equipment with capability of qualitative and quick estimation of the radioisotopes. The system was used for the mobile radiological mapping of Bangalore and Mumbai city and demonstrated its capability for use in environmental radiation monitoring during any radiological emergency requirement the results of which are presented here. (abstract)

  7. Semiautomatic digital imaging system for cytogenetic analysis

    International Nuclear Information System (INIS)

    Chaubey, R.C.; Chauhan, P.C.; Bannur, S.V.; Kulgod, S.V.; Chadda, V.K.; Nigam, R.K.

    1999-08-01

    The paper describes a digital image processing system, developed indigenously at BARC for size measurement of microscopic biological objects such as cell, nucleus and micronucleus in mouse bone marrow; cytochalasin-B blocked human lymphocytes in-vitro; numerical counting and karyotyping of metaphase chromosomes of human lymphocytes. Errors in karyotyping of chromosomes by the imaging system may creep in due to lack of well-defined position of centromere or extensive bending of chromosomes, which may result due to poor quality of preparation. Good metaphase preparations are mandatory for precise and accurate analysis by the system. Additional new morphological parameters about each chromosome have to be incorporated to improve the accuracy of karyotyping. Though the experienced cytogenetisist is the final judge; however, the system assists him/her to carryout analysis much faster as compared to manual scoring. Further, experimental studies are in progress to validate different software packages developed for various cytogenetic applications. (author)

  8. Worklist handling in workflow-enabled radiological application systems

    Science.gov (United States)

    Wendler, Thomas; Meetz, Kirsten; Schmidt, Joachim; von Berg, Jens

    2000-05-01

    For the next generation integrated information systems for health care applications, more emphasis has to be put on systems which, by design, support the reduction of cost, the increase inefficiency and the improvement of the quality of services. A substantial contribution to this will be the modeling. optimization, automation and enactment of processes in health care institutions. One of the perceived key success factors for the system integration of processes will be the application of workflow management, with workflow management systems as key technology components. In this paper we address workflow management in radiology. We focus on an important aspect of workflow management, the generation and handling of worklists, which provide workflow participants automatically with work items that reflect tasks to be performed. The display of worklists and the functions associated with work items are the visible part for the end-users of an information system using a workflow management approach. Appropriate worklist design and implementation will influence user friendliness of a system and will largely influence work efficiency. Technically, in current imaging department information system environments (modality-PACS-RIS installations), a data-driven approach has been taken: Worklist -- if present at all -- are generated from filtered views on application data bases. In a future workflow-based approach, worklists will be generated by autonomous workflow services based on explicit process models and organizational models. This process-oriented approach will provide us with an integral view of entire health care processes or sub- processes. The paper describes the basic mechanisms of this approach and summarizes its benefits.

  9. Digital System Categorization Methodology to Support Integration of Digital Instrumentation and Control Models into PRAs

    International Nuclear Information System (INIS)

    Arndt, Steven A.

    2011-01-01

    It has been suggested that by categorizing the various digital systems used in safety critical applications in nuclear power plants, it would be possible to determine which systems should be modeled in the analysis of the larger plant wide PRA, at what level of detail the digital system should be modeled and using which methods. The research reported in this paper develops a categorization method using system attributes to permit a modeler to more effectively model the systems that will likely have the most critical contributions to the overall plant safety and to more effectively model system interactions for those digital systems where the interactions are most important to the overall accuracy and completeness of the plant PRA. The proposed methodology will categorize digital systems based on certain attributes of the systems themselves and how they will be used in the specific application. This will help determine what digital systems need to be modeled and at what level of detail, and can be used to guide PRA analysis and regulatory reviews. The three-attribute categorization strategy that was proposed by Arndt is used as the basis for the categorization methodology developed here. The first attribute, digital system complexity, is based on Type Il interactions defined by Aldemir and an overall digital system size and complexity index. The size and complexity index used are previously defined software complexity metrics. Potential sub-attributes of digital system complexity include, design complexity, software complexity, hardware complexity, system function complexity and testability. The second attribute, digital system interactions/inter-conductivity, is a combination of Rushby's coupling and Ademir's Type I interactions. Digital systems that are loosely coupled and/or have very few Type I interaction would not interact dynamically with the overall system and would have a low interactions/inter-conductivity score. Potential sub-attributes of digital system

  10. Digital System Categorization Methodology to Support Integration of Digital Instrumentation and Control Models into PRAs

    Energy Technology Data Exchange (ETDEWEB)

    Arndt, Steven A. [U.S. Nuclear Regulatory Commission, Washington D.C. (United States)

    2011-08-15

    It has been suggested that by categorizing the various digital systems used in safety critical applications in nuclear power plants, it would be possible to determine which systems should be modeled in the analysis of the larger plant wide PRA, at what level of detail the digital system should be modeled and using which methods. The research reported in this paper develops a categorization method using system attributes to permit a modeler to more effectively model the systems that will likely have the most critical contributions to the overall plant safety and to more effectively model system interactions for those digital systems where the interactions are most important to the overall accuracy and completeness of the plant PRA. The proposed methodology will categorize digital systems based on certain attributes of the systems themselves and how they will be used in the specific application. This will help determine what digital systems need to be modeled and at what level of detail, and can be used to guide PRA analysis and regulatory reviews. The three-attribute categorization strategy that was proposed by Arndt is used as the basis for the categorization methodology developed here. The first attribute, digital system complexity, is based on Type Il interactions defined by Aldemir and an overall digital system size and complexity index. The size and complexity index used are previously defined software complexity metrics. Potential sub-attributes of digital system complexity include, design complexity, software complexity, hardware complexity, system function complexity and testability. The second attribute, digital system interactions/inter-conductivity, is a combination of Rushby's coupling and Ademir's Type I interactions. Digital systems that are loosely coupled and/or have very few Type I interaction would not interact dynamically with the overall system and would have a low interactions/inter-conductivity score. Potential sub-attributes of

  11. CEBAF NEW DIGITAL LLRF SYSTEM EXTENDED FUNCTIONALITY

    International Nuclear Information System (INIS)

    T. Allison; K. Davis; H. Dong; C. Hovater; L. King; J. Musson; T. Plawski

    2007-01-01

    The new digital LLRF system for the CEBAF 12GeV accelerator will perform a variety of tasks, beyond field control [1]. In this paper we present the superconducting cavity resonance control system designed to minimize RF power during gradient ramp and to minimize RF power during steady state operation. Based on the calculated detuning angle, which represents the difference between reference and cavity resonance frequency, the cavity length will be adjusted with a mechanical tuner. The tuner has two mechanical driving devices, a stepper motor and a piezo-tuner, to yield a combination of coarse and fine control. Although LLRF piezo processing speed can achieve 10 kHz bandwidth, only 10 Hz speed is needed for 12 GeV upgrade. There will be a number of additional functions within the LLRF system; heater controls to maintain cryomodule's heat load balance, ceramic window temperature monitoring, waveguide vacuum interlocks, ARC detector interlock and quench detection. The additional functions will be divided between the digital board, incorporating an Altera FPGA and an embedded EPICS IOC. This paper will also address hardware evolution and test results performed with different SC cavities

  12. Experience of digital control systems in Scandinavian BWRs

    International Nuclear Information System (INIS)

    Rydahl, I.

    1989-01-01

    Since 1984 digital control systems have been in operation in various Scandinavian BWRs. Examples of such digital control systems are: dual microprocessor based system for complete control of radwaste plant, three channel recirculation control system, and three channel feedwater control system. This paper describes Swedish development from one channel through three channel analog control systems to digital systems. The author describes experience of digital control systems during design, testing, commissioning and operation. The main benefits of digital compared with analog technology are discussed. Especially the outstanding facility of using a built-in process simulator for commissioning and tuning. The use of digital technology in nuclear safety system and future plans are dealt with

  13. Attention for pediatric interventional radiology

    International Nuclear Information System (INIS)

    Zhu Ming; Cheng Yongde

    2005-01-01

    Radiological interventions possess wide utilization in the diagnosis and treatment for pediatric patients. Pediatric interventional radiology is an important branch of interventional radiology and also an important branch of pediatric radiology. Pediatric interventional radiology has grown substantially over the last 30 years, radiologists closely cooperation with surgeons and other physicians providing a new horizon in the management of pediatric diseases in western countries. It includes pediatric cardiac interventional radiology, pediatric neuro-interventional radiology, pediatric vascular interventional radiology, pediatric nonvascular interventional radiology, pediatric tumor interventional radiology and others. In the United States, every children hospital which owns two hundred beds has to have special trained interventional radiologists in radiologic department installing with advanced digital subtraction angiographic equipment. Interventional therapeutic procedures and diagnostic angiography have been proceeding more and more for the congenital and acquired diseases of children. The promising results give use uprising and interventional therapy as an alternative or a replacement or supplement to surgical operation. Pediatric interventional radiology is rather underdeveloped in China with a few special pediatric interventional radiologist, lack of digital subtraction angiography equipment. Pediatric radiologists have no enough field for interventional procedures such as pediatric neuro-interventional radiology and pediatric vascular interventional radiology. In the contrary adult interventional radiologists do have better interventional jobs in China and Pediatric cardiologists also share the same trend. They perform angiocardiography for congenital heart diseases and treat congenital heart disease with interventional procedures including balloon dilation of valves and vessels, coil embolization of collaterals, patent ducts and other arterial fistulae

  14. Distributed and recoverable digital control system

    Science.gov (United States)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A real-time multi-tasking digital control system with rapid recovery capability is disclosed. The control system includes a plurality of computing units comprising a plurality of redundant processing units, with each of the processing units configured to generate one or more redundant control commands. One or more internal monitors are employed for detecting data errors in the control commands. One or more recovery triggers are provided for initiating rapid recovery of a processing unit if data errors are detected. The control system also includes a plurality of actuator control units each in operative communication with the computing units. The actuator control units are configured to initiate a rapid recovery if data errors are detected in one or more of the processing units. A plurality of smart actuators communicates with the actuator control units, and a plurality of redundant sensors communicates with the computing units.

  15. Random digital encryption secure communication system

    Science.gov (United States)

    Doland, G. D. (Inventor)

    1982-01-01

    The design of a secure communication system is described. A product code, formed from two pseudorandom sequences of digital bits, is used to encipher or scramble data prior to transmission. The two pseudorandom sequences are periodically changed at intervals before they have had time to repeat. One of the two sequences is transmitted continuously with the scrambled data for synchronization. In the receiver portion of the system, the incoming signal is compared with one of two locally generated pseudorandom sequences until correspondence between the sequences is obtained. At this time, the two locally generated sequences are formed into a product code which deciphers the data from the incoming signal. Provision is made to ensure synchronization of the transmitting and receiving portions of the system.

  16. Radiology's value chain.

    Science.gov (United States)

    Enzmann, Dieter R

    2012-04-01

    A diagnostic radiology value chain is constructed to define its main components, all of which are vulnerable to change, because digitization has caused disaggregation of the chain. Some components afford opportunities to improve productivity, some add value, while some face outsourcing to lower labor cost and to information technology substitutes, raising commoditization risks. Digital image information, because it can be competitive at smaller economies of scale, allows faster, differential rates of technological innovation of components, initiating a centralization-to-decentralization technology trend. Digitization, having triggered disaggregation of radiology's professional service model, may soon usher in an information business model. This means moving from a mind-set of "reading images" to an orientation of creating and organizing information for greater accuracy, faster speed, and lower cost in medical decision making. Information businesses view value chain investments differently than do small professional services. In the former model, producing a better business product will extend image interpretation beyond a radiologist's personal fund of knowledge to encompass expanding external imaging databases. A follow-on expansion with integration of image and molecular information into a report will offer new value in medical decision making. Improved interpretation plus new integration will enrich and diversify radiology's key service products, the report and consultation. A more robust, information-rich report derived from a "systems" and "computational" radiology approach will be facilitated by a transition from a professional service to an information business. Under health care reform, radiology will transition its emphasis from volume to greater value. Radiology's future brightens with the adoption of a philosophy of offering information rather than "reads" for decision making. Staunchly defending the status quo via turf wars is unlikely to constitute a

  17. Digital I and C system upgrade integration technique

    International Nuclear Information System (INIS)

    Huang, H. W.; Shih, C.; Wang, J. R.; Huang, K. C.

    2012-01-01

    This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure Events. A

  18. Digital I and C system upgrade integration technique

    Energy Technology Data Exchange (ETDEWEB)

    Huang, H. W. [Inst. of Nuclear Energy Research (INER), No. 1000, Wenhua Road, Chiaan Village, Longtan Township, Taoyuan County, 32546, Taiwan (China); Shih, C. [Inst. of Nuclear Engineering and Science, National Tsing Hua Univ., 101, Sec. 2, Kuang Fu Rd, Hsinchu, Taiwan (China); Wang, J. R. [Inst. of Nuclear Energy Research (INER), No. 1000, Wenhua Road, Chiaan Village, Longtan Township, Taoyuan County, 32546, Taiwan (China); Huang, K. C. [Inst. of Nuclear Engineering and Science, National Tsing Hua Univ., 101, Sec. 2, Kuang Fu Rd, Hsinchu, Taiwan (China)

    2012-07-01

    This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure

  19. Fast skin dose estimation system for interventional radiology.

    Science.gov (United States)

    Takata, Takeshi; Kotoku, Jun'ichi; Maejima, Hideyuki; Kumagai, Shinobu; Arai, Norikazu; Kobayashi, Takenori; Shiraishi, Kenshiro; Yamamoto, Masayoshi; Kondo, Hiroshi; Furui, Shigeru

    2018-03-01

    To minimise the radiation dermatitis related to interventional radiology (IR), rapid and accurate dose estimation has been sought for all procedures. We propose a technique for estimating the patient skin dose rapidly and accurately using Monte Carlo (MC) simulation with a graphical processing unit (GPU, GTX 1080; Nvidia Corp.). The skin dose distribution is simulated based on an individual patient's computed tomography (CT) dataset for fluoroscopic conditions after the CT dataset has been segmented into air, water and bone based on pixel values. The skin is assumed to be one layer at the outer surface of the body. Fluoroscopic conditions are obtained from a log file of a fluoroscopic examination. Estimating the absorbed skin dose distribution requires calibration of the dose simulated by our system. For this purpose, a linear function was used to approximate the relation between the simulated dose and the measured dose using radiophotoluminescence (RPL) glass dosimeters in a water-equivalent phantom. Differences of maximum skin dose between our system and the Particle and Heavy Ion Transport code System (PHITS) were as high as 6.1%. The relative statistical error (2 σ) for the simulated dose obtained using our system was ≤3.5%. Using a GPU, the simulation on the chest CT dataset aiming at the heart was within 3.49 s on average: the GPU is 122 times faster than a CPU (Core i7-7700K; Intel Corp.). Our system (using the GPU, the log file, and the CT dataset) estimated the skin dose more rapidly and more accurately than conventional methods.

  20. RSVP radiology

    International Nuclear Information System (INIS)

    Kirks, D.R.; Chaffee, D.J.

    1990-01-01

    This paper develops a relative scale of value for pediatric radiology (RSVPR). Neither the HCFA/ACA Relative Value Scale nor the Workload Measurement System developed by Health and Welfare Canada specifically addressed pediatric radiologic examinations. Technical and professional charges for examinations at Children's Hospital Medical Center were reviewed and compared with time and cost analysis. A scale was developed with chest radiography (PA and lateral views) assigned a value of 1. After review by pediatric radiologic technologists, radiologic administrators, pediatric radiologists, and chairs of departments of children's hospitals, this proposed scale was modified to reflect more accurately relative value components of pediatric radiologic and imaging examinations

  1. Using the digital reactor control systems at NPP

    International Nuclear Information System (INIS)

    Schirl, G.; Hertel, J.

    2006-01-01

    A conception of application of the digital reactor control systems (RCS) at NPP is presented. The digital RCS architecture and safety ensuring are considered. The strategy and algorithm of the operating NPP equipping with the new digital RCS are given too [ru

  2. Analysis of data flow and activities at radiology reporting stations for design and evaluation of digital work stations

    International Nuclear Information System (INIS)

    Mun, S.K.; Benson, H.; Welsh, C.; Elliott, L.P.; Zeman, R.

    1987-01-01

    Definition of necessary and desirable functional capabilities of PACS work stations is critical in the design of digital systems for the successful clinical acceptance of digital imaging networks. The authors conducted a detailed time motion study of data flow pattern, diagnostic decision making, and reporting activities at current film alternators for neuroradiology, body CT, and pulmonary service. The measured parameters include data volume, data presentation speed, frequency of use of previous studies, efforts needed to retrieve previous studies, time required for diagnosis, frequency and duration of consultation with referring physicians, frequency of interruptions, and dictation time an defficiency. The result of this study provides critical information in designing digital work stations for various services

  3. Radiologic image compression -- A review

    International Nuclear Information System (INIS)

    Wong, S.; Huang, H.K.; Zaremba, L.; Gooden, D.

    1995-01-01

    The objective of radiologic image compression is to reduce the data volume of and to achieve a lot bit rate in the digital representation of radiologic images without perceived loss of image quality. However, the demand for transmission bandwidth and storage space in the digital radiology environment, especially picture archiving and communication systems (PACS) and teleradiology, and the proliferating use of various imaging modalities, such as magnetic resonance imaging, computed tomography, ultrasonography, nuclear medicine, computed radiography, and digital subtraction angiography, continue to outstrip the capabilities of existing technologies. The availability of lossy coding techniques for clinical diagnoses further implicates many complex legal and regulatory issues. This paper reviews the recent progress of lossless and lossy radiologic image compression and presents the legal challenges of using lossy compression of medical records. To do so, the authors first describe the fundamental concepts of radiologic imaging and digitization. Then, the authors examine current compression technology in the field of medical imaging and discuss important regulatory policies and legal questions facing the use of compression in this field. The authors conclude with a summary of future challenges and research directions. 170 refs

  4. Accelerator driven systems from the radiological safety point of view

    Indian Academy of Sciences (India)

    application of the probabilistic safety analysis technique by assessing the probability and ... Technological and theoretical developments necessary for more precise .... Monte Carlo-based) to enable quick estimation of radiological hazards.

  5. RASCAL [Radiological Assessment System for Consequence AnaLysis]: A screening model for estimating doses from radiological accidents

    International Nuclear Information System (INIS)

    Sjoreen, A.L.; Athey, G.F.; Sakenas, C.A.; McKenna, T.J.

    1988-01-01

    The Radiological Assessment System for Consequence AnaLysis (RASCAL) is a new MS-DOS-based dose assessment model which has been written for the US Nuclear Regulatory Commission for use during response to radiological emergencies. RASCAL is designed to provide crude estimates of the effects of an accident while the accident is in progress and only limited information is available. It has been designed to be very simple to use and to run quickly. RASCAL is unique in that it estimates the source term based on fundamental plant conditions and does not rely solely on release rate estimation (e.g., Ci/sec of I-131). Therefore, it can estimate consequences of accidents involving unmonitored pathways or projected failures. RASCAL will replace the older model, IRDAM. 6 refs

  6. Strategies in the digital printing value system

    OpenAIRE

    Mejtoft, Thomas

    2006-01-01

    The research objective of this thesis is to identify corporate strategies and strategic decisions in the digital printing business and to analyze how these have evolved due to the introduction of digital printing. This thesis comprises three separate studies, all based on qualitative case methodology. The first study is focused on digital printing houses and how their business strategies have changed due to their investment in digital printing production equipment. The second study concentrat...

  7. ICRP Publication 138: Ethical Foundations of the System of Radiological Protection.

    Science.gov (United States)

    Cho, K-W; Cantone, M-C; Kurihara-Saio, C; Le Guen, B; Martinez, N; Oughton, D; Schneider, T; Toohey, R; ZöLzer, F

    2018-02-01

    Despite a longstanding recognition that radiological protection is not only a matter of science, but also ethics, ICRP publications have rarely addressed the ethical foundations of the system of radiological protection explicitly. The purpose of this publication is to describe how the Commission has relied on ethical values, either intentionally or indirectly, in developing the system of radiological protection with the objective of presenting a coherent view of how ethics is part of this system. In so doing, it helps to clarify the inherent value judgements made in achieving the aim of the radiological protection system as underlined by the Commission in Publication 103. Although primarily addressed to the radiological protection community, this publication is also intended to address authorities, operators, workers, medical professionals, patients, the public, and its representatives (e.g. NGOs) acting in the interest of the protection of people and the environment. This publication provides the key steps concerning the scientific, ethical, and practical evolutions of the system of radiological protection since the first ICRP publication in 1928. It then describes the four core ethical values underpinning the present system: beneficence/ non-maleficence, prudence, justice, and dignity. It also discusses how these core ethical values relate to the principles of radiological protection, namely justification, optimisation, and limitation. The publication finally addresses key procedural values that are required for the practical implementation of the system, focusing on accountability, transparency, and inclusiveness. The Commission sees this publication as a founding document to be elaborated further in different situations and circumstances.

  8. Usability evaluation of Laboratory and Radiology Information Systems integrated into a hospital information system.

    Science.gov (United States)

    Nabovati, Ehsan; Vakili-Arki, Hasan; Eslami, Saeid; Khajouei, Reza

    2014-04-01

    This study was conducted to evaluate the usability of widely used laboratory and radiology information systems. Three usability experts independently evaluated the user interfaces of Laboratory and Radiology Information Systems using heuristic evaluation method. They applied Nielsen's heuristics to identify and classify usability problems and Nielsen's severity rating to judge their severity. Overall, 116 unique heuristic violations were identified as usability problems. In terms of severity, 67 % of problems were rated as major and catastrophic. Among 10 heuristics, "consistency and standards" was violated most frequently. Moreover, mean severity of problems concerning "error prevention" and "help and documentation" heuristics was higher than of the others. Despite widespread use of specific healthcare information systems, they suffer from usability problems. Improving the usability of systems by following existing design standards and principles from the early phased of system development life cycle is recommended. Especially, it is recommended that the designers design systems that inhibit the initiation of erroneous actions and provide sufficient guidance to users.

  9. Development of prototype digital LLRF system at RRCAT

    International Nuclear Information System (INIS)

    Tiwari, Nitesh; Bagduwal, Pritam S.; Sharma, Dheeraj; Chakraborty, Shoubhik; Lad, Mahendra; Hannurkar, P.R.

    2013-01-01

    RF field is used in accelerator to accelerate the charge particles. The beam parameters depend highly on the stability of the RF field. Due to dynamic beam loading conditions the variations in RF parameters of accelerating structures needs to be controlled precisely, hence low level RF feedback control system plays vital role. Considering revolutionary development in the field of digital electronics and inherent advantages of digital systems, digital LLRF control system work was taken up. The digital LLRF system consists of two major units namely RF processing and digital processing. RF processing unit uses I/Q modulator for amplitude and phase control. This unit provides synchronized clock using ÷16 pre-scalar and also performs up conversion and down conversion for synchronized LO and IF generation respectively, along with required amplification and filtering. Digital processing unit takes down converted IF signal with appropriate sampling rate for I/Q detection. To extract the amplitude and phase information I/Q data is digitally filtered and processed using CORDIC algorithm in FPGA. I/Q modulator is used for controlling the amplitude and phase of RF field. Prototype development of digital LLRF control system for 325 MHz, 650 MHz is in progress. Digital LLRF system at 505 MHz has been installed in one RF station of Indus-2 RF system. In this paper development of prototype Digital LLRF system at RFSD, Raja Ramanna Centre for Advanced Technology and results are presented. (author)

  10. Class 1E digital systems studies

    International Nuclear Information System (INIS)

    Hecht, H.; Tai, A.T.; Tso, K.S.

    1993-10-01

    This document is furnished as part of the effort to develop NRC Class 1E Digital Computer Systems Guidelines which is Task 8 of USAF Rome Laboratories Contract F30602-89-D-0100. The report addresses four major topics, namely, computer programming languages, software design and development, software testing and fault tolerance and fault avoidance. The topics are intended as stepping stones leading to a Draft Regulatory Guide document. As part of this task a small scale survey of software fault avoidance and fault tolerance practices was conducted among vendors of nuclear safety related systems and among agencies that develop software for other applications demanding very high reliability. The findings of the present report are in part based on the survey and in part on review of software literature relating to nuclear and other critical installations, as well as on the authors' experience in these areas

  11. Development of the Digital Reactor Safety System

    International Nuclear Information System (INIS)

    Lee, Dong Young; Lee, C. K.; Hwang, I. K.

    2008-04-01

    Objectives of Project - Development of Digital Safety Grade PLC and Licensing - Development of Safety System(RPS) and Licensing - Development of Safety System(ESF-CCS) and Licensing Content and Result of Project - POSAFE-Q PLC : Development of PLC platform for Shin-UCN unit 1 and 2 ·Development Scope : Processor module, Power module, 3 kinds of Communication module, Bus extension module(Master and Slave), 16 kinds of Input and Output module ·PLC application software development tool(pSET) - IDiPS RPS and IDiPS ESF-CCS : Development of PPS for Sin-UCN 1 and 2 ·Development Scope - 4-channels RPS with the KNICS inherent architecture - A part of 1-channels ESF-CCS with the KNICS inherent architecture - Licensing ·optical Report Submitted and Expected to finish the licensing process until Aug. 2008

  12. Visible digital watermarking system using perceptual models

    Science.gov (United States)

    Cheng, Qiang; Huang, Thomas S.

    2001-03-01

    This paper presents a visible watermarking system using perceptual models. %how and why A watermark image is overlaid translucently onto a primary image, for the purposes of immediate claim of copyright, instantaneous recognition of owner or creator, or deterrence to piracy of digital images or video. %perceptual The watermark is modulated by exploiting combined DCT-domain and DWT-domain perceptual models. % so that the watermark is visually uniform. The resulting watermarked image is visually pleasing and unobtrusive. The location, size and strength of the watermark vary randomly with the underlying image. The randomization makes the automatic removal of the watermark difficult even though the algorithm is known publicly but the key to the random sequence generator. The experiments demonstrate that the watermarked images have pleasant visual effect and strong robustness. The watermarking system can be used in copyright notification and protection.

  13. Radiological dose and metadata management

    International Nuclear Information System (INIS)

    Walz, M.; Madsack, B.; Kolodziej, M.

    2016-01-01

    This article describes the features of management systems currently available in Germany for extraction, registration and evaluation of metadata from radiological examinations, particularly in the digital imaging and communications in medicine (DICOM) environment. In addition, the probable relevant developments in this area concerning radiation protection legislation, terminology, standardization and information technology are presented. (orig.) [de

  14. Data-Fusion for a Vision-Aided Radiological Detection System: Sensor dependence and Source Tracking

    Science.gov (United States)

    Stadnikia, Kelsey; Martin, Allan; Henderson, Kristofer; Koppal, Sanjeev; Enqvist, Andreas

    2018-01-01

    The University of Florida is taking a multidisciplinary approach to fuse the data between 3D vision sensors and radiological sensors in hopes of creating a system capable of not only detecting the presence of a radiological threat, but also tracking it. The key to developing such a vision-aided radiological detection system, lies in the count rate being inversely dependent on the square of the distance. Presented in this paper are the results of the calibration algorithm used to predict the location of the radiological detectors based on 3D distance from the source to the detector (vision data) and the detectors count rate (radiological data). Also presented are the results of two correlation methods used to explore source tracking.

  15. Automated Radiology-Pathology Module Correlation Using a Novel Report Matching Algorithm by Organ System.

    Science.gov (United States)

    Dane, Bari; Doshi, Ankur; Gfytopoulos, Soterios; Bhattacharji, Priya; Recht, Michael; Moore, William

    2018-05-01

    Radiology-pathology correlation is time-consuming and is not feasible in most clinical settings, with the notable exception of breast imaging. The purpose of this study was to determine if an automated radiology-pathology report pairing system could accurately match radiology and pathology reports, thus creating a feedback loop allowing for more frequent and timely radiology-pathology correlation. An experienced radiologist created a matching matrix of radiology and pathology reports. These matching rules were then exported to a novel comprehensive radiology-pathology module. All distinct radiology-pathology pairings at our institution from January 1, 2016 to July 1, 2016 were included (n = 8999). The appropriateness of each radiology-pathology report pairing was scored as either "correlative" or "non-correlative." Pathology reports relating to anatomy imaged in the specific imaging study were deemed correlative, whereas pathology reports describing anatomy not imaged with the particular study were denoted non-correlative. Overall, there was 88.3% correlation (accuracy) of the radiology and pathology reports (n = 8999). Subset analysis demonstrated that computed tomography (CT) abdomen/pelvis, CT head/neck/face, CT chest, musculoskeletal CT (excluding spine), mammography, magnetic resonance imaging (MRI) abdomen/pelvis, MRI brain, musculoskeletal MRI (excluding spine), breast MRI, positron emission tomography (PET), breast ultrasound, and head/neck ultrasound all demonstrated greater than 91% correlation. When further stratified by imaging modality, CT, MRI, mammography, and PET demonstrated excellent correlation (greater than 96.3%). Ultrasound and non-PET nuclear medicine studies demonstrated poorer correlation (80%). There is excellent correlation of radiology imaging reports and appropriate pathology reports when matched by organ system. Rapid, appropriate radiology-pathology report pairings provide an excellent opportunity to close feedback loop to the

  16. In Vitro Evaluation of Proximal Carious Lesions Using Digital Radiographic Systems

    Directory of Open Access Journals (Sweden)

    Mayana Soares Vieira

    2015-01-01

    Full Text Available The study aimed to compare the sensitivity and specificity of digital radiographic systems for the diagnosis of proximal carious lesions. Extracted human teeth (3 canines, 3 premolars, and 3 molars were submitted to one of three types of proximal lesions (demineralized area, cavity affecting the enamel alone, and cavity affecting enamel and dentin. Bitewing radiographs were obtained from each system (Sirona, Kodak, and Schick and evaluated by 12 raters (4 dental students, 4 radiology specialists, and 4 dentists. The chi-squared test was used to determine the frequency of correct diagnoses among the different systems, raters, teeth, and types of lesion. Sensitivity and specificity regarding demineralized areas were calculated for each system. The frequencies of correct diagnoses were found: Schick (70.8%, Kodak (63.9%, Sirona (59.0%, specialists (69.4%, students (62.5%, dentists (61.8%, premolars (70.1%, canines (65.3%, and molars (58.3%. No significant differences were found among the different systems, raters, or teeth (P>0.05. Sensitivity and specificity were 0.64 and 0.47 (Schick, 0.56 and 0.50 (Sirona, and 0.48 and 0.58 (Kodak. The most correct diagnoses were achieved using the Schick digital system on premolars and evaluated by specialists in radiology. The systems demonstrated low sensitivity and specificity for the diagnosis of demineralized areas.

  17. A customized digital monitoring and display system for nonpower reactors

    International Nuclear Information System (INIS)

    Ficaro, E.P.; Wehe, D.K.

    1989-01-01

    A digital data acquisition system for monitoring plant variables has been designed and implemented at the University of Michigan's Ford Nuclear Reactor (FNR), a 2-MW open-pool research reactor. The digital data provided by this system will be useful for: improved operator training, real-time experimental calculations, noise analysis, closed-loop control, and expert system applications. This paper describes the analog-to-digital (A/D) transitions and the associated applications and benefits experienced

  18. Analysis of the impact of digital tomosynthesis on the radiological investigation of patients with suspected pulmonary lesions on chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Quaia, Emilio; Baratella, Elisa; Cernic, Stefano; Lorusso, Arianna; Casagrande, Federica; Cioffi, Vincenzo; Cova, Maria Assunta [University of Trieste (Italy), Department of Radiology, Cattinara Hospital, Trieste (Italy)

    2012-09-15

    To assess the impact of digital tomosynthesis (DTS) on the radiological investigation of patients with suspected pulmonary lesions on chest radiography (CXR). Three hundred thirty-nine patients (200 male; age, 71.19 {+-} 11.9 years) with suspected pulmonary lesion(s) on CXR underwent DTS. Two readers prospectively analysed CXR and DTS images, and recorded their diagnostic confidence: 1 or 2 = definite or probable benign lesion or pseudolesion deserving no further diagnostic workup; 3 = indeterminate; 4 or 5 = probable or definite pulmonary lesion deserving further diagnostic workup by computed tomography (CT). Imaging follow-up by CT (n = 76 patients), CXR (n = 256) or histology (n = 7) was the reference standard. DTS resolved doubtful CXR findings in 256/339 (76 %) patients, while 83/339 (24 %) patients proceeded to CT. The mean interpretation time for DTS (mean {+-} SD, 220 {+-} 40 s) was higher (P < 0.05; Wilcoxon test) than for CXR (110 {+-} 30 s), but lower than CT (600 {+-} 150 s). Mean effective dose was 0.06 mSv (range 0.03-0.1 mSv) for CXR, 0.107 mSv (range 0.094-0.12 mSv) for DTS, and 3 mSv (range 2-4 mSv) for CT. DTS avoided the need for CT in about three-quarters of patients with a slight increase in the interpretation time and effective dose compared to CXR. (orig.)

  19. Design and simulation of a totally digital image system for medical image applications

    International Nuclear Information System (INIS)

    Archwamety, C.

    1987-01-01

    The Totally Digital Imaging System (TDIS) is based on system requirements information from the Radiology Department, University of Arizona Health Science Center. This dissertation presents the design of this complex system, the TDIS specification, the system performance requirements, and the evaluation of the system using the computer-simulation programs. Discrete-event simulation models were developed for the TDIS subsystems, including an image network, imaging equipment, storage migration algorithm, data base archive system, and a control and management network. The simulation system uses empirical data generation and retrieval rates measured at the University Medical Center hospital. The entire TDIS system was simulated in Simscript II.5 using a VAX 8600 computer system. Simulation results show the fiber-optical-image network to be suitable; however, the optical-disk-storage system represents a performance bottleneck

  20. Fault tolerant digital control systems for boiling water reactors

    International Nuclear Information System (INIS)

    Chakraborty, S.; Cash, N.R.

    1986-01-01

    In a Boiling Water Reactor nuclear power plant, the power generation control function is divided into several systems, each system controlling only a part of the total plant. Presently, each system is controlled by conventional analog or digital logic circuits with little interaction for coordinated control. The advent of microprocessors has allowed the development of distributed fault-tolerant digital controls. The objective is to replace these conventional controls with fault-tolerant digital controls connected together with digital communication links to form a fully integrated nuclear power plant control system

  1. Digital Autonomous Terminal Access Communication (DATAC) system

    Science.gov (United States)

    Novacki, Stanley M., III

    1987-01-01

    In order to accommodate the increasing number of computerized subsystems aboard today's more fuel efficient aircraft, the Boeing Co. has developed the DATAC (Digital Autonomous Terminal Access Control) bus to minimize the need for point-to-point wiring to interconnect these various systems, thereby reducing total aircraft weight and maintaining an economical flight configuration. The DATAC bus is essentially a local area network providing interconnections for any of the flight management and control systems aboard the aircraft. The task of developing a Bus Monitor Unit was broken down into four subtasks: (1) providing a hardware interface between the DATAC bus and the Z8000-based microcomputer system to be used as the bus monitor; (2) establishing a communication link between the Z8000 system and a CP/M-based computer system; (3) generation of data reduction and display software to output data to the console device; and (4) development of a DATAC Terminal Simulator to facilitate testing of the hardware and software which transfer data between the DATAC's bus and the operator's console in a near real time environment. These tasks are briefly discussed.

  2. Development of Final Running Test System for Digital Systems

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Lee, Eui-Jong; Lim, Hee-Taek; Kim, Min-Seok

    2016-01-01

    In nuclear industry, the newly designed systems to upgrade are qualified to meet IEEE standards and the regulatory guidelines for their functions, performance and reliability requirements. Failure Mode and Effect Analysis, Fault Tree Analysis, and Hazard Analysis have been used to improve the reliability of the control system. To ensure the completeness of the software, the verification and validation processes are carried out during the development process. In spite of the many efforts depending on the analysis and procedures, there are limitations to improve the reliability. The lessons learned from the currently installed system failures show the incompleteness of the final integration test. The current point-to-point and logic-to-logic separate test procedures manually performed by the engineers can cause some procedures missed and have effects on the critical functions. The design processes of the digital systems are met in accordance with the international standards and regulatory guidelines. The lessons learned from the failures of the running digital systems showed the limitations of the current verification and validation efforts. The various improvements and attempts have been considered including the expert review processes and the completeness of the test. In this paper, the Final Running Test Method evaluating the completeness of the digital system using the control patterns and the Test System Architecture are proposed

  3. Development of Final Running Test System for Digital Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang-Dae; Lee, Eui-Jong; Lim, Hee-Taek; Kim, Min-Seok [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In nuclear industry, the newly designed systems to upgrade are qualified to meet IEEE standards and the regulatory guidelines for their functions, performance and reliability requirements. Failure Mode and Effect Analysis, Fault Tree Analysis, and Hazard Analysis have been used to improve the reliability of the control system. To ensure the completeness of the software, the verification and validation processes are carried out during the development process. In spite of the many efforts depending on the analysis and procedures, there are limitations to improve the reliability. The lessons learned from the currently installed system failures show the incompleteness of the final integration test. The current point-to-point and logic-to-logic separate test procedures manually performed by the engineers can cause some procedures missed and have effects on the critical functions. The design processes of the digital systems are met in accordance with the international standards and regulatory guidelines. The lessons learned from the failures of the running digital systems showed the limitations of the current verification and validation efforts. The various improvements and attempts have been considered including the expert review processes and the completeness of the test. In this paper, the Final Running Test Method evaluating the completeness of the digital system using the control patterns and the Test System Architecture are proposed.

  4. Connected digit speech recognition system for Malayalam language

    Indian Academy of Sciences (India)

    A connected digit speech recognition is important in many applications such as automated banking system, catalogue-dialing, automatic data entry, automated banking system, etc. This paper presents an optimum speaker-independent connected digit recognizer for Malayalam language. The system employs Perceptual ...

  5. Digital control of wind tunnel magnetic suspension and balance systems

    Science.gov (United States)

    Britcher, Colin P.; Goodyer, Michael J.; Eskins, Jonathan; Parker, David; Halford, Robert J.

    1987-01-01

    Digital controllers are being developed for wind tunnel magnetic suspension and balance systems, which in turn permit wind tunnel testing of aircraft models free from support interference. Hardware and software features of two existing digital control systems are reviewed. Some aspects of model position sensing and system calibration are also discussed.

  6. Modernization of control system using the digital control system

    International Nuclear Information System (INIS)

    Carrasco, J. A.; Fernandez, L.; Jimenez, A.

    2002-01-01

    Nowadays, all plant automation tendencies are based on the use of Digital Control System. In big industrial plants the control systems employed are Distributed Control Systems (DCS). The addition of these systems in nuclear power plants,implies an important adaptation process, because most of them were installed using analog control systems. This paper presents the objectives and the first results obtained, in a modernization project, focused in obtaining an engineering platform for making test and analysis of changes prior to their implementation in a nuclear plant. Modernization, Upgrade, DCS, Automation, Simulation, Training. (Author)

  7. Digital protection in power plants. Electrical unit and line protection. Digital protection systems for NPP

    International Nuclear Information System (INIS)

    Kaczmarek, A.

    2000-01-01

    In this presentation author deals with the digital protection systems for nuclear power plants. The evolution of protection devices, protection concept for power plants, concept of functional redundancy, references for digital protection, benefits for the customer well as concept fault recorder are presented. (author)

  8. Creation of a Cell-Based Digital Cadastral Mapping System (Digital ...

    African Journals Online (AJOL)

    Digital cadastre enhances land transaction activities to be conducted in a business manner. Similarly, land subdivision or boundary redefinition, land registration and land marketing are achieved with better accuracy. This paper discusses the need to introduce a national Cell-Based Digital Cadastral Mapping System model ...

  9. Digital Dentistry — Digital Impression and CAD/CAM System Applications

    Directory of Open Access Journals (Sweden)

    Gabor Alin-Gabriel

    2017-03-01

    Full Text Available Digital imprint and computer-aided design/computer-aided manufacture (CAD/CAM systems offer several benefits compared to traditional techniques. The use of a CAD/CAM system to scan preparations and generate restorations in-office, removes a second appointment for the patient. The existence of precision benefits in using complete systems and chairside scanning systems, has been proven. CAD/CAM restorations have a good longevity and meet the accepted clinical parameters. New digital impression methods are presently accessible, and before long, the long-awaited goal of sparing patients of one the most unpleasant practices in clinical dentistry, acquiring dental impressions, will be exchanged by intraoral digital scanning. CAD/CAM systems existing nowadays, can feed data through accurate digital scans created from plaster models, straight to manufacturing systems that can shape ceramic or resin restorations with no requirement of a physical copy of the prepared, adjacent, and antagonist teeth.

  10. Interactive tele-radiological segmentation systems for treatment and diagnosis.

    Science.gov (United States)

    Zimeras, S; Gortzis, L G

    2012-01-01

    Telehealth is the exchange of health information and the provision of health care services through electronic information and communications technology, where participants are separated by geographic, time, social and cultural barriers. The shift of telemedicine from desktop platforms to wireless and mobile technologies is likely to have a significant impact on healthcare in the future. It is therefore crucial to develop a general information exchange e-medical system to enables its users to perform online and offline medical consultations through diagnosis. During the medical diagnosis, image analysis techniques combined with doctor's opinions could be useful for final medical decisions. Quantitative analysis of digital images requires detection and segmentation of the borders of the object of interest. In medical images, segmentation has traditionally been done by human experts. Even with the aid of image processing software (computer-assisted segmentation tools), manual segmentation of 2D and 3D CT images is tedious, time-consuming, and thus impractical, especially in cases where a large number of objects must be specified. Substantial computational and storage requirements become especially acute when object orientation and scale have to be considered. Therefore automated or semi-automated segmentation techniques are essential if these software applications are ever to gain widespread clinical use. The main purpose of this work is to analyze segmentation techniques for the definition of anatomical structures under telemedical systems.

  11. Interactive Tele-Radiological Segmentation Systems for Treatment and Diagnosis

    Directory of Open Access Journals (Sweden)

    S. Zimeras

    2012-01-01

    Full Text Available Telehealth is the exchange of health information and the provision of health care services through electronic information and communications technology, where participants are separated by geographic, time, social and cultural barriers. The shift of telemedicine from desktop platforms to wireless and mobile technologies is likely to have a significant impact on healthcare in the future. It is therefore crucial to develop a general information exchange e-medical system to enables its users to perform online and offline medical consultations through diagnosis. During the medical diagnosis, image analysis techniques combined with doctor’s opinions could be useful for final medical decisions. Quantitative analysis of digital images requires detection and segmentation of the borders of the object of interest. In medical images, segmentation has traditionally been done by human experts. Even with the aid of image processing software (computer-assisted segmentation tools, manual segmentation of 2D and 3D CT images is tedious, time-consuming, and thus impractical, especially in cases where a large number of objects must be specified. Substantial computational and storage requirements become especially acute when object orientation and scale have to be considered. Therefore automated or semi-automated segmentation techniques are essential if these software applications are ever to gain widespread clinical use. The main purpose of this work is to analyze segmentation techniques for the definition of anatomical structures under telemedical systems.

  12. Analysis of image quality according to BMI of digital chest radiography: Focusing on bureau of radiological health evaluation

    International Nuclear Information System (INIS)

    Jin, Seong Jin; Im, In Chul; Cho, Ji Hwan

    2017-01-01

    Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was 30.17±4.73 and the average waist circumference was 66.91±4.67 cm. The mean Body Mass Index value was 20.21±2.23, the mean value of mAs was 3.04±0.78, and the mean value of Bureau of Radiological Health was 79.83±8.45. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality

  13. Analysis of image quality according to BMI of digital chest radiography: Focusing on bureau of radiological health evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Seong Jin [Gammaknife center, Inje University Haeundae Paik Hospital, Busan (Korea, Republic of); Im, In Chul [Dept. of Radiological Science, Dongeui University, Busan (Korea, Republic of); Cho, Ji Hwan [Dept. of Health Care Clinic, Inje University Busan Paik Hospital, Busan (Korea, Republic of)

    2017-03-15

    Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was 30.17±4.73 and the average waist circumference was 66.91±4.67 cm. The mean Body Mass Index value was 20.21±2.23, the mean value of mAs was 3.04±0.78, and the mean value of Bureau of Radiological Health was 79.83±8.45. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

  14. The cyclical monitoring system for digital power supplies at SSRF

    International Nuclear Information System (INIS)

    Tang Junlong; Li Deming; Shen Tianjian

    2009-01-01

    Based on available digital PS testing system and long-distance monitoring hardwares, the cyclical monitoring system for digital power supplies (PS) was developed at SSRF. Two models, i.e.long-distance cyclical monitoring and local cyclical monitoring, were established. The software developed in LabVIEW language was applied to the two models without any user interface modification. The user interface is simple. The system is suitable for debugging the digital PSs during long-distance monitoring and examining the performance. The long-distance model imitates the digital PSs' status for fault analysis and communication between the digital PS and the centre control room. The local model simultaneously examines stability of 18 new PSs for 24 h, monitors the PS controller, and detects malfunction. Parameters and status of the controller can be stored in Excel or Text file. The two models have been used at SSRF for monitoring the digital PSs. (authors)

  15. Radiology in the 21st century

    International Nuclear Information System (INIS)

    Carson, P.L.; Seltzer, S.E.; Gore, J.C.; Heiiman, R.S.; Abrams, H.L.; Davis, K.A.; Henkelman, M.R.

    1987-01-01

    On the leading edge in ''high-tech'' medicine, radiology is experiencing several revolutions simultaneously that promise an exciting future. New imaging methods and digital technologies not only offer novel ways to view tissues but also provide opportunities for quantitative evaluation of function and even permit determination of metabolic status. New approaches to technology assessment are being explored that alter the ways in which equipment and procedures are introduced into clinical medicine. With the plethora of radiology services available, the radiologist must serve as a consultant in the triage of patients in radiology and the dissemination of information from radiology. For similar reasons, training in diagnostic radiology may eventually accommodate to the concept of specialization along organ-system lines. Without question, radiology is destined for an exciting period as it moves into the 21st century

  16. Clinical application of digital angiographic system DIGITEX2400

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Masumi; Tanaka, Shuji; Fujino, Yoshiyuki; Yasumi, Masayuki (Shimadzu Corp., Kyoto (Japan))

    1992-10-01

    Digital angiography (DA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. And under the condition of the spread of interventional angiography, not only high quality image but also ease of operation are required to the system. The clinical usefullness of digital angiographic system DIGITEX2400 are reported in this paper. (author).

  17. Clinical application of digital angiographic system DIGITEX2400

    International Nuclear Information System (INIS)

    Kawai, Masumi; Tanaka, Shuji; Fujino, Yoshiyuki; Yasumi, Masayuki

    1992-01-01

    Digital angiography (DA) has been of widespread use clinically, and it has attracted considerable attention in angiographic examination today. And under the condition of the spread of interventional angiography, not only high quality image but also ease of operation are required to the system. The clinical usefullness of digital angiographic system DIGITEX2400 are reported in this paper. (author)

  18. Clinical Assessment of a New Stereoscopic Digital Angiography System

    International Nuclear Information System (INIS)

    Moll, Thierry; Douek, Philippe; Finet, Gerard; Turjman, Francis; Picard, Catherine; Revel, Didier; Amiel, Michel

    1998-01-01

    Purpose: To assess the clinical feasibility of an experimental modified angiographic system capable of real-time digital stereofluoroscopy and stereography in X-ray angiography, using a twin-focus tube and a stereoscopic monitor. Methods: We report the experience obtained in 37 patients with a well-documented examination. The patients were examined for coronary angiography (11 cases), aortography (7 cases), pulmonary angiography (6 cases), inferior vena cava filter placement (2 cases), and cerebral angiography (11 cases). Six radiologists were asked to use stereoscopic features for fluoroscopy and angiography. A questionnaire was designed to record their subjective evaluation of stereoscopic image quality, ergonomics of the system, and its medical interest. Results: Stereofluoroscopy was successfully used in 25 of 37 cases; diplopia and/or ghost images were reported in 6 cases. It was helpful for aortic catheterization in 10 cases and for selective catheterization in 5 cases. In stereoangiography, depth was easily and accurately perceived in 27 of 37 cases; diplopia and/or ghost images were reported in 4 cases. A certain gain in the three-dimensional evaluation of the anatomy and relation between vessels and lesions was noted. As regards ergonomic considerations, polarized spectacles were not considered cumbersome. Visual fatigue and additional work were variously reported. Stereoshift tuning before X-ray acquisition was not judged to be a limiting factor. Conclusion: A twin-focus X-ray tube and a polarized shutter for stereoscopic display allowed effective real-time three-dimensional perception of angiographic images. Our clinical study suggests no clear medical interest for diagnostic examinations, but the field of interventional radiology needs to be investigated

  19. Advanced domestic digital satellite communications systems experiments

    Science.gov (United States)

    Iso, A.; Izumisawa, T.; Ishida, N.

    1984-02-01

    The characteristics of advanced digital transmission systems were measured, using newly developed small earth stations and a K-band and C-band communication satellite. Satellite link performance for data, facsimile, video and packet switching information transmission at bit rates ranging from 6.4 kbit/s to 6.3 Mbit/s have been confirmed, using a small K-band earth station and a demand-assignment time division multiple access system. A low-capacity omni-use C-band terminal experiment has verified a telephone channel transmission performance by spread-spectrum multiple access. Single point to multipoint transmission characteristics of the 64 kbit/s data signals from the computer center were tested, using a receive-only 4 GHz earth terminal. Basic satellite link performance was confirmed under clear-sky conditions. Precise satellite orbit and attitude keeping experiments were carried out to obtain precise satellite antenna pointing accuracy for development of K-band earth stations that do not require satellite tracking equipment. Precise station keeping accuracy of 0.02 degrees was obtained.

  20. [Telemedicine with digital video transport system].

    Science.gov (United States)

    Hahm, Joon Soo; Shimizu, Shuji; Nakashima, Naoki; Byun, Tae Jun; Lee, Hang Lak; Choi, Ho Soon; Ko, Yong; Lee, Kyeong Geun; Kim, Sun Il; Kim, Tae Eun; Yun, Jiwon; Park, Yong Jin

    2004-06-01

    The growth of technology based on internet protocol has affected on the informatics and automatic controls of medical fields. The aim of this study was to establish the telemedical educational system by developing the high quality image transfer using the DVTS (digital video transmission system) on the high-speed internet network. Using telemedicine, we were able to send surgical images not only to domestic areas but also to international area. Moreover, we could discuss the condition of surgical procedures in the operation room and seminar room. The Korean-Japan cable network (KJCN) was structured in the submarine between Busan and Fukuoka. On the other hand, the Korea advanced research network (KOREN) was used to connect between Busan and Seoul. To link the image between the Hanyang University Hospital in Seoul and Kyushu University Hospital in Japan, we started teleconference system and recorded image-streaming system with DVTS on the circumstance with IPv4 network. Two operative cases were transmitted successfully. We could keep enough bandwidth of 60 Mbps for two-line transmission. The quality of transmitted moving image had no frame loss with the rate 30 per second. The sound was also clear and the time delay was less than 0.3 sec. Our study has demonstrated the feasibility of domestic and international telemedicine. We have established an international medical network with high-quality video transmission over internet protocol. It is easy to perform, reliable, and also economical. Thus, it will be a promising tool in remote medicine for worldwide telemedical communication in the future.

  1. Development and validation of novel digitalized cervicography system

    Science.gov (United States)

    Kim, Soo-Nyung; Kim, Yun Hwan; Nam, Kye-Hyun; Lee, Seon-Kyung; Lee, Tae Sung; Choi, Ho-Sun; Han, Sei-Jun

    2016-01-01

    Objective Digital cervicography systems would be expected to reduce the costs of film cervicography, and provide the opportunity for "telemedicine-based" screening. We aimed to develop web-based digital cervicography system, and validate it compared with conventional film cervicography. Methods A hundred cases from five centers were prospectively included, and cervical images (analogue, digitalized by scanning analogue, and digital) were taken separately using both analogue (Cerviscope) and digital camera (Dr. Cervicam) in each patient. Nine specialists evaluated the three kinds of images of each case with time interval between evaluations of each image. To validate novel digitalized system, we analyzed intra-observer variance among evaluation results of three kinds of images. Results Sixty-three cases were finally analyzed after excluding technically defective cases that cannot be evaluable on analogue images. The generalized kappa for analogue versus digital image was 0.83, for analogue versus scanned image 0.72, and for digital versus scanned image was 0.71; all were in excellent consensus. Conclusion Digitalized cervicography system can be substituted for the film cervicography very reliably, and can be used as a promising telemedicine tool for cervical cancer screening. PMID:27200314

  2. Advanced digital image archival system using MPEG technologies

    Science.gov (United States)

    Chang, Wo

    2009-08-01

    Digital information and records are vital to the human race regardless of the nationalities and eras in which they were produced. Digital image contents are produced at a rapid pace from cultural heritages via digitalization, scientific and experimental data via high speed imaging sensors, national defense satellite images from governments, medical and healthcare imaging records from hospitals, personal collection of photos from digital cameras. With these mass amounts of precious and irreplaceable data and knowledge, what standards technologies can be applied to preserve and yet provide an interoperable framework for accessing the data across varieties of systems and devices? This paper presents an advanced digital image archival system by applying the international standard of MPEG technologies to preserve digital image content.

  3. Quality control: comparison of images quality with screen film system and digital mammography CR

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Nogueira, Maria do Socorro

    2008-01-01

    The mammography screen film system should be used as part of processing chemicals, revelation process, equipment and this system has have a progressive replacing by the digital technology Full Field Digital Mammography FFDM, Computed Radiography (CR) Mammography and hardcopy. This new acquisition process of medical images has improved radiology section; however it is necessary efficient means for evaluating of the quality parameters. It should be considered taking into account the adaptation of the existent equipment and that procedures adopted for the exam, as well the adaptation of the new mammography films, the radiologist view box constitutes a part of the quality control program. This program aims at obtaining radiography with good quality that allows obtaining more information for the diagnosis and decreases the patient dose. For evaluation the quality image, this article is focused on presenting the differences regarding the acquired images through simulator mammography radiographic PMMA (Poly methyl methacrylate) in CR Mammography system and screen film system. The tests were accomplished at the same equipment of Mammography with the Automatic Exposure Control using a tension of 28 kV for both systems. The quality tests evaluated the spatial resolution, the own structures of the phantom, artifacts, optical density and contrast with conventional and laser films by mammography system. The installation for the accomplishment of the test has a quality control program. The evaluation was based on the pattern developed by the competent organ of the State of Minas Gerais. In this study, it was verified that the suitable Phantom Mama used by the Brazilian School of Radiology for conventional mammography did not obtain satisfactory result for Spatial Resolution in the digital mammography system CR. The final aim of this work is to obtain parameters to characterize the reference phantom quality image in an objective way. These parameters will be used to compare

  4. The evolving system of radiological protection: the nuclear industry perspective

    International Nuclear Information System (INIS)

    Coates, R.

    2003-01-01

    . (A set of key examples is listed herein.) In our view, the current system comprising of the dose limit (1 mSv pa) and the ALARA Principle provides the necessary flexibility and tools to regulators for addressing any country specific or site specific settings, and there are already good examples of this. Again, we believe that this matter is best left for discussion and agreement between the local stakeholders rather than at an international level. We strongly support the need to establish an international approach to defining a level of dose below which society may legitimately maintain that an individual is adequately protected., and hence the allocation of further resources to control the source on radiological health grounds would be inappropriate. WNA considers that this dose is not less than a few tens of micro-sieverts. This approach should be supported by guidance on the appropriate level of conservatism within dose assessments, both in the context of exclusion/clearance/exemption and critical groups in general. WNA supports the continued use of the term 'ALARA, economic and social factors being taken into account'. Collective dose is a useful concept in the optimisation of occupational exposure: in addition it needs to be supplemented by the consideration of the number of workers exposed at the higher levels and by wider pragmatic experience. Public collective dose is of very limited utility in decision making, and little if any weight should be given to exposures at long timescales and exceedingly trivial levels of individual exposure. WNA welcomes both the lead taken by ICRP to bring the protection of non-human biota into a coherent overall framework addressing the totality of radiological protection, and the recognition that the current system has in practice provided an appropriate standard of environmental protection. On this basis the development of the future system of protection must not impose a disproportionate burden on operators. The focus for

  5. Audit of radiology communication systems for critical, urgent, and unexpected significant findings

    International Nuclear Information System (INIS)

    Duncan, K.A.; Drinkwater, K.J.; Dugar, N.; Howlett, D.C.

    2016-01-01

    Aim: To determine the compliance of UK radiology departments and trusts/healthcare organisations with National Patient Safety Agency and Royal College of Radiologist's published guidance on the communication of critical, urgent, and unexpected significant radiological findings. Materials and methods: A questionnaire was sent to all UK radiology department audit leads asking for details of their current departmental policy regarding the issuing of alerts; use of automated electronic alert systems; methods of notification of clinicians of critical, urgent, and unexpected significant radiological findings; monitoring of results receipt; and examples of the more common types of serious pathologies for which alerts were issued. Results: One hundred and fifty-four of 229 departments (67%) responded. Eighty-eight percent indicated that they had a policy in place for the communication of critical, urgent, and unexpected significant radiological findings. Only 34% had an automated electronic alert system in place and only 17% had a facility for service-wide electronic tracking of radiology reports. In only 11 departments with an electronic acknowledgement system was someone regularly monitoring the read rate. Conclusion: There is wide variation in practice across the UK with regard to the communication and monitoring of reports with many departments/trusts not fully compliant with published UK guidance. Despite the widespread use of electronic systems, only a minority of departments/trusts have and use electronic tracking to ensure reports have been read and acted upon. - Highlights: • UK wide audit of communication of significant radiology results. • 88% of departments have a communication policy in place. • 34% of departments have an automated electronic alert system. • 17% of Trusts have facility for service wide electronic tracking of radiology reports.

  6. Experience with digital acoustic monitoring systems for PWRs and BWRs

    International Nuclear Information System (INIS)

    Olma, B.J.

    1998-01-01

    Substantial progress could be reached both in system technics and in application of digital acoustic monitoring systems for assessing mechanical integrity of reactor primary systems. For the surveillance of PWRs and BWRs during power operation of the plants, acoustic signals of Loose Parts Monitoring System sensors are continuously monitored for signal bursts associated with metallic impacts. ISTec/GRS experience with its digital systems MEDEA and RAMSES has shown that acoustic signature analysis is very successful for detecting component failures at an early stage. Methods for trending and classification of digital burst signals are shown, experience with their practical use will be presented. (author)

  7. Remotely Piloted Aircraft Systems and a Wireless Sensors Network for Radiological Accidents

    Directory of Open Access Journals (Sweden)

    A. Reyes-Muñoz

    2016-01-01

    Full Text Available In critical radiological situations, the real time information that we could get from the disaster area becomes of great importance. However, communication systems could be affected after a radiological accident. The proposed network in this research consists of distributed sensors in charge of collecting radiological data and ground vehicles that are sent to the nuclear plant at the moment of the accident to sense environmental and radiological information. Afterwards, data would be analyzed in the control center. Collected data by sensors and ground vehicles would be delivered to a control center using Remotely Piloted Aircraft Systems (RPAS as a message carrier. We analyze the pairwise contacts, as well as visiting times, data collection, capacity of the links, size of the transmission window of the sensors, and so forth. All this calculus was made analytically and compared via network simulations.

  8. Fine tuning of work practices of common radiological investigations performed using computed radiography system

    International Nuclear Information System (INIS)

    Livingstone, Roshan S.; Timothy Peace, B.S.; Sunny, S.; Victor Raj, D.

    2007-01-01

    Introduction: The advent of the computed radiography (CR) has brought about remarkable changes in the field of diagnostic radiology. A relatively large cross-section of the human population is exposed to ionizing radiation on account of common radiological investigations. This study is intended to audit radiation doses imparted to patients during common radiological investigations involving the use of CR systems. Method: The entrance surface doses (ESD) were measured using thermoluminescent dosimeters (TLD) for various radiological investigations performed using the computed radiography (CR) systems. Optimization of radiographic techniques and radiation doses was done by fine tuning the work practices. Results and conclusion: Reduction of radiation doses as high as 47% was achieved during certain investigations with the use of optimized exposure factors and fine-tuned work practices

  9. Rolls-Royce digital Rod Control System

    International Nuclear Information System (INIS)

    Pouillot, M.

    2010-01-01

    Full text of publication follows: Rolls-Royce has developed a new generation of Rod Control System, based on 40 years of experience. The fifth-generation Rod Control System (RCS) from Rolls-Royce offers a reliable, modular design with adaptability to your preferred platform, for modernization projects or new reactors. Flexible implementation provides the option for you to keep existing cabinets, which permits you to optimize installation approach. Main features for the power part: - Control Rod Drive Mechanism (CRDM) type: 3-coil. - Independent control of each sub-bank. - Each sub-bank is controlled by a cycler unit and 3 identical power racks, each including 4 identical power modules and a common power-supply module. - Coil-per-coil digital control: each power module embeds power-conversion, current-control, and current-monitoring functions for one coil. Control and monitoring are carried out by separate electronics in the module. Current is digitized and fully monitored by means of min-max templates. - A double-hold function is included: a power module assigned to a gripper will activate its coil if a fault risking to cause a reactor trip occurs. - Power modules are standardized, hot-pluggable and self-configured: a power module includes a set of parameters for each type of coil SG, MG, LC. The module recognizes the rack it is plugged in, and chooses automatically parameters to be used. Main benefits: - Reduced operational, maintenance, training, and inventory costs: standardization of power modules and integration of control and monitoring on the same PC-card lead to a drastic reduction of spare part types, and simplification of the system. - Easy maintenance: - Replacement of a power module solves nearly all failures due to current control or monitoring for a coil. It is done instantly thanks to hot-plug capability. - On the front plate of power-modules, LEDs provide useful information for diagnostic: current setpoint from cycler, output current bar

  10. Audit of radiology communication systems for critical, urgent, and unexpected significant findings.

    Science.gov (United States)

    Duncan, K A; Drinkwater, K J; Dugar, N; Howlett, D C

    2016-03-01

    To determine the compliance of UK radiology departments and trusts/healthcare organisations with National Patient Safety Agency and Royal College of Radiologist's published guidance on the communication of critical, urgent, and unexpected significant radiological findings. A questionnaire was sent to all UK radiology department audit leads asking for details of their current departmental policy regarding the issuing of alerts; use of automated electronic alert systems; methods of notification of clinicians of critical, urgent, and unexpected significant radiological findings; monitoring of results receipt; and examples of the more common types of serious pathologies for which alerts were issued. One hundred and fifty-four of 229 departments (67%) responded. Eighty-eight percent indicated that they had a policy in place for the communication of critical, urgent, and unexpected significant radiological findings. Only 34% had an automated electronic alert system in place and only 17% had a facility for service-wide electronic tracking of radiology reports. In only 11 departments with an electronic acknowledgement system was someone regularly monitoring the read rate. There is wide variation in practice across the UK with regard to the communication and monitoring of reports with many departments/trusts not fully compliant with published UK guidance. Despite the widespread use of electronic systems, only a minority of departments/trusts have and use electronic tracking to ensure reports have been read and acted upon. Copyright © 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Radiological analysis of polyostotic fibrous dysplasia in skeletal system

    International Nuclear Information System (INIS)

    Shin, Ma Rie; Kim, Jin Sik; Kim, Han Suk; Park, Soo Soung

    1984-01-01

    Over a period of recent 3 years, the 5 cases of polyostotic fibrous dysplasia were proven histologically at National Medical Center, and they were evaluated and analyzed radiologically and clinically. The results were as follows: 1. The age of 5 patients ranged from 12 to 21. 2. In general, clinical symptoms of these patients were pain of affected sites and swelling , fracture, walking disturbance of lower extremities. 3. The order of frequent site of polyostotic fibrous dysplasia was skull (4 cases), femur (3 cases), maxilla (2 case), humerus, tibia, rib, radius, metacarpal bone and phalanx. 4. The characteristic radiological findings of polyostotic fibrous dysplasia were multicystic lesions with ground glass appearance, osteosclerosis, cortical thinning and pathologic fracture and deformity of long bones. Particularly, in the extremities, multicystic radiolucencies, groud glass appearance, shepherd's crook and coxa vara deformities were noticed, and in the skull and maxilla, sclerotic changes were principally demonstrated.

  12. The information security needs in radiological information systems-an insight on state hospitals of Iran, 2012.

    Science.gov (United States)

    Farhadi, Akram; Ahmadi, Maryam

    2013-12-01

    Picture Archiving and Communications System (PACS) was originally developed for radiology services over 20 years ago to capture medical images electronically. Medical diagnosis methods are based on images such as clinical radiographs, ultrasounds, CT scans, MRIs, or other imaging modalities. Information obtained from these images is correlated with patient information. So with regards to the important role of PACS in hospitals, we aimed to evaluate the PACS and survey the information security needed in the Radiological Information system. First, we surveyed the different aspects of PACS that should be in any health organizations based on Department of Health standards and prepared checklists for assessing the PACS in different hospitals. Second, we surveyed the security controls that should be implemented in PACS. Checklists reliability is affirmed by professors of Tehran Science University. Then, the final data are inputted in SPSS software and analyzed. The results indicate that PACS in hospitals can transfer patient demographic information but they do not show route of information. These systems are not open source. They don't use XML-based standard and HL7 standard for exchanging the data. They do not use DS digital signature. They use passwords and the user can correct or change the medical information. PACS can detect alternation rendered. The survey of results demonstrates that PACS in all hospitals has the same features. These systems have the patient demographic data but they do not have suitable flexibility to interface network or taking reports. For the privacy of PACS in all hospitals, there were passwords for users and the system could show the changes that have been made; but there was no water making or digital signature for the users.

  13. Lessons learned on digital systems safety

    International Nuclear Information System (INIS)

    Sivertsen, Terje

    2005-06-01

    A decade ago, in 1994, lessons learned from Halden research activities on digital systems safety were summarized in the reports HWR-374 and HWR-375, under the title 'A Lessons Learned Report on Software Dependability'. The reports reviewed all activities made at the Halden Project in this field since 1977. As such, the reports provide a wealth of information on Halden research. At the same time, the lessons learned from the different activities are made more accessible to the reader by being summarized in terms of results, conclusions and recommendations. The present report provides a new lessons learned report, covering the Halden Project research activities in this area from 1994 to medio 2005. As before, the emphasis is on the results, conclusions and recommendations made from these activities, in particular how they can be utilized by different types of organisations, such as licensing authorities, safety assessors, power companies, and software developers. The contents of the report have been edited on the basis of input from a large number of Halden work reports, involving many different authors. Brief summaries of these reports are included in the last part of the report. (Author)

  14. Energy-aware design of digital systems

    Energy Technology Data Exchange (ETDEWEB)

    Gruian, F.

    2000-02-01

    Power and energy consumption are important issues in many digital applications, for reasons such as packaging cost and battery life-span. With the development of portable computing and communication, an increasing number of research groups are addressing power and energy related issues at various stages during the design process. Most of the work done in this area focuses on lower abstraction levels, such as gate or transistor level. Ideally, a power and energy-efficient design flow should consider the power and energy issues at every stage in the design process. Therefore, power and energy aware methods, applicable early in the design process are required. In this trend, the thesis presents two high-level design methods addressing power and energy consumption minimization. The first of the two approaches we describe, targets power consumption minimization during behavioral synthesis. This is carried out by minimizing the switching activity, while taking the correlations between signals into account. The second approach performs energy consumption minimization during system-level design, by choosing the most energy-efficient schedule and configuration of resources. Both methods make use of the constraint programming paradigm to model the problems in an elegant manner. The experimental results presented in this thesis show the impact of addressing the power and energy related issues early in the design process.

  15. An Overview of the Asynchronous Digital Systems – Part 3

    Directory of Open Access Journals (Sweden)

    Mihai Timis

    2008-01-01

    Full Text Available Implementation methods for the digital asynchronous systems use different predefined models like self timed circuits, speed independent circuits, delay insensitive circuits, handshake protocol implementation in asynchronous systems,C Muller circuits.

  16. An Overview of the Asynchronous Digital Systems – Part 2

    Directory of Open Access Journals (Sweden)

    Mihai Timis

    2008-01-01

    Full Text Available Implementation methods for the digital asynchronous systems use different predefined models like self timed circuits, speed independent circuits, delay insensitive circuits, handshake protocol implementation in asynchronous systems,C Muller circuits.

  17. Development and application of all-digital monitoring system

    International Nuclear Information System (INIS)

    Xu Tao; Li Jing; Wang Wei

    2014-01-01

    All digital control system has developed into a mainstream means of monitoring, and achieved information, intelligence, and networking. All-digital control system is characterized by clear image, large transport stream, so the higher the data storage and network bandwidth should be required. Existing analog surveillance system architecture, hardware and software configuration can not meet the requirements of all-digital monitoring system, so how to solve the original analog surveillance system is gradually transformed into fully digital monitoring system, to avoid incompatibility issues in surveillance monitoring system upgrade become a research project. This paper describes the advantages and future direction of megapixels camera and proposes key technologies to solve the resolution and frame rate with the actual project requirements, achieves a core technology of megapixels video surveillance system, and proposes solutions for the actual renovation project problems. (authors)

  18. Digital Systems Security in the nuclear scope

    International Nuclear Information System (INIS)

    Amado, I.

    2011-01-01

    Overall nuclear power plants and in particular the Spanish, work well, but to modernize and improve the operation of existing Spanish plants, perhaps the natural evolution is to use digital technologies.

  19. Design of a laser scanner for a digital mammography system.

    Science.gov (United States)

    Rowlands, J A; Taylor, J E

    1996-05-01

    We have developed a digital readout system for radiographic images using a scanning laser beam. In this system, electrostatic charge images on amorphous selenium (alpha-Se) plates are read out using photo-induced discharge (PID). We discuss the design requirements of a laser scanner for the PID system and describe its construction from commercially available components. The principles demonstrated can be adapted to a variety of digital imaging systems.

  20. Digital imaging and electronic patient records in pathology using an integrated department information system with PACS.

    Science.gov (United States)

    Kalinski, Thomas; Hofmann, Harald; Franke, Dagmar-Sybilla; Roessner, Albert

    2002-01-01

    Picture archiving and communication systems have been widely used in radiology thus far. Owing to the progress made in digital photo technology, their use in medicine opens up further opportunities. In the field of pathology, digital imaging offers new possiblities for the documentation of macroscopic and microscopic findings. Digital imaging has the advantage that the data is permanently and readily available, independent of conventional archives. In the past, PACS was a separate entity. Meanwhile, however, PACS has been integrated in DIS, the department information system, which was also run separately in former times. The combination of these two systems makes the administration of patient data, findings and images easier. Moreover, thanks to the introduction of special communication standards, a data exchange between different department information systems and hospital information systems (HIS) is possible. This provides the basis for a communication platform in medicine, constituting an electronic patient record (EPR) that permits an interdisciplinary treatment of patients by providing data of findings and images from clinics treating the same patient. As the pathologic diagnosis represents a central and often therapy-determining component, it is of utmost importance to add pathologic diagnoses to the EPR. Furthermore, the pathologist's work is considerably facilitated when he is able to retrieve additional data from the patient file. In this article, we describe our experience gained with the combined PACS and DIS systems recently installed at the Department of Pathology, University of Magdeburg. Moreover, we evaluate the current situation and future prospects for PACS in pathology.

  1. Comparison of the image quality of digital radiography system and film screen system - Radiologist' rating of the visibility of normal anatomic - Structures in chest PA, Skull radiograph and K. U. B

    International Nuclear Information System (INIS)

    Song, Kounn Sik; Kim, Young Goo; Lee, Jong Beum; Kim, Kun Sang

    1987-01-01

    Digital image acquisition and display is widely used in computed tomography, ultrasonography, digital subtraction angiography, nuclear medicine and magnetic resonance image. But most of the radiological examinations performed in radiology department are made by using conventional system. The development of the digital radiography system is essential if totally digitized radiology department is desired. The advantages of digitizing the radiographic information are usually discussed in terms of PACS (picture archiving and communication system), furthermore there are many other advantages such as contrast modification, spatial filtering subtraction and superimposition of the images through the image processing by computer. Currently several approaches are under development or in clinical use, the most promising approach is the use of imaging plate composed of photostimulate phosphors such as barium fluorohalide crystal read with a He-Ne laser to produce digital radiographic images. Another promising approach is scan projection radiography. The authors performed the clinical study of comparing the image qualities of digital radiography system using scanning laser luminescence (FCR) and conventional film-screen system in chest PA, skull radiography and K. U. B. in terms of the visibility of the normal anatomic structure rating those (qualities) on a scale of 0 to 3 and obtained the following results. Normal contrast digital images are comparable to conventional film-screen images, but the images of high frequency enhancement is far superior to conventional film-screen especially in peripherally located structures such as skin, subcutaneous fat, musculoskeletal systems, nasal bone, inner and outer table of the skull including the diploic space, paranasal sinuses, nasopharynx and larynx, trachea and main bronchi, mediastinal structures, retrocardiac and subphrenic vascular markings. Another promising aspects of digital radiography system is its wide exposure latitude and

  2. All Digital IQ Servo-System for CERN Linacs

    CERN Document Server

    Rohlev, A; Garoby, R

    2003-01-01

    A new VME based system has been developed and built at CERN for the servo loops regulating the field in the linac accelerating structure. It makes use of high speed digital In-phase/Quadrature (IQ) detection, digital processing, and digital IQ modulation. The digital processing and IQ modulation is done in a single PLD. The system incorporates continually variable set points, iterative learning, feed forward as well as extensive diagnostics and other features well suited for digital implementations. Built on a single VME card, it will be first used in the energy ramping RF chain of the CERN Heavy Ion Linac (linac 3) and later for upgrading the present proton linac (linac 2). This system serves also as a prototype for the future Superconducting Proton Linac (SPL). The design principle and the experimental results are described.

  3. Digital stethoscope system: the feasibility of cardiac auscultation

    Science.gov (United States)

    Pariaszewska, Katarzyna; Młyńczak, Marcel; Niewiadomski, Wiktor; Cybulski, Gerard

    2013-10-01

    The application of the digital stethoscope system is a new tendency in methods of cardiac auscultation. Heart sounds, generated by the fluctuations of blood velocity and vibrations of muscle structure, are an important signal in the primary diagnosis of heart diseases. Since the XIXs century for physical examination an analog stethoscope was used, but the development of microelectronics enable the construction of digital stethoscopes which started modern phonocardiography. The typical hardware of the system could be divided into analog and digital parts, respectively. The first one consists of microphone and pre-amplifier. The second one contains a microcontroller with peripherals for data saving and transmission. Usually the specialized software is applied for the signal acquisition and digital signal processing (filtering, spectral analysis and others). This paper presents an overview of methods used in cardiac auscultation and expected developing path in the future. It also contains the description of our digital stethoscope system, which is planned to be used in poliphysiographical studies.

  4. Intermediate Frequency Digital Receiver Based on Multi-FPGA System

    Directory of Open Access Journals (Sweden)

    Chengchang Zhang

    2016-01-01

    Full Text Available Aiming at high-cost, large-size, and inflexibility problems of traditional analog intermediate frequency receiver in the aerospace telemetry, tracking, and command (TTC system, we have proposed a new intermediate frequency (IF digital receiver based on Multi-FPGA system in this paper. Digital beam forming (DBF is realized by coordinated rotation digital computer (CORDIC algorithm. An experimental prototype has been developed on a compact Multi-FPGA system with three FPGAs to receive 16 channels of IF digital signals. Our experimental results show that our proposed scheme is able to provide a great convenience for the design of IF digital receiver, which offers a valuable reference for real-time, low power, high density, and small size receiver design.

  5. Robust digital controllers for uncertain chaotic systems: A digital redesign approach

    Energy Technology Data Exchange (ETDEWEB)

    Ababneh, Mohammad [Department of Controls, FMC Kongsberg Subsea, FMC Energy Systems, Houston, TX 77067 (United States); Barajas-Ramirez, Juan-Gonzalo [CICESE, Depto. De Electronica y Telecomunicaciones, Ensenada, BC, 22860 (Mexico); Chen Guanrong [Centre for Chaos Control and Synchronization, Department of Electronic Engineering, City University of Hong Kong (China); Shieh, Leang S. [Department of Electrical and Computer Engineering, University of Houston, Houston, TX 77204-4005 (United States)

    2007-03-15

    In this paper, a new and systematic method for designing robust digital controllers for uncertain nonlinear systems with structured uncertainties is presented. In the proposed method, a controller is designed in terms of the optimal linear model representation of the nominal system around each operating point of the trajectory, while the uncertainties are decomposed such that the uncertain nonlinear system can be rewritten as a set of local linear models with disturbed inputs. Applying conventional robust control techniques, continuous-time robust controllers are first designed to eliminate the effects of the uncertainties on the underlying system. Then, a robust digital controller is obtained as the result of a digital redesign of the designed continuous-time robust controller using the state-matching technique. The effectiveness of the proposed controller design method is illustrated through some numerical examples on complex nonlinear systems--chaotic systems.

  6. Knowledge Organisation Systems in North American Digital Library Collections

    Science.gov (United States)

    Shiri, Ali; Chase-Kruszewski, Sarah

    2009-01-01

    Purpose: The purpose of this paper is to report an investigation into the types of knowledge organisation systems (KOSs) utilised in North American digital library collections. Design/methodology/approach: The paper identifies, analyses and deep scans online North American hosted digital libraries. It reviews the literature related to the…

  7. Research of digital constant fraction discriminator in PET system

    International Nuclear Information System (INIS)

    Du Yaoyao; Hu Xuanhou; Wu Jianping; Wang Peilin; Li Xiaohui; Li Daowu; Li Ke; Wei Long

    2012-01-01

    The research on digital constant fraction discriminator of spike pulse signal in PET detector is introduced. Based on FPGA technique, rapid signal's time information is extracted via DCFD algorithm after a high-speed ADC digitization. Experiment results show that time resolution of DCFD is 772 ps, which meets the requirement of time measurement in PET system well. (authors)

  8. Managing library and information systems in the digital world ...

    African Journals Online (AJOL)

    This paper discusses the challenges and opportunities towards managing library and information system in relation to access the digital world's knowledge. Academic libraries are expected to provide access to information and digital material resources available within their reach. However, the Nigerian libraries especially ...

  9. Long-distance digital signal transfers between trigger system and TOF system of BES III

    International Nuclear Information System (INIS)

    Liu Guangdong; Liu Shubin; An Qi

    2007-01-01

    This article introduces a design of digital signals communication between the trigger system and the TOF system of BES III. The design can support the BES III successfully, which is based on fiber digital communication, FPGA etc. (authors)

  10. Investigation of physical imaging properties in various digital radiography systems

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hoi Woun [Dept. of Radiological Science, Baekseok Culture University, Cheonan (Korea, Republic of); Min, Jung Hwan [Dept. of Radiological technology, Shingu University, Seongnam (Korea, Republic of); Yoon, Yong Su [Dept. of Health Sciences, Graduate School of Medical Sciences, Kyushu University, Kyushu (Japan); Kim, Jung Min [Dept. of Health and Environmental Science, College of Health Science, Korea University, Seoul (Korea, Republic of)

    2017-09-15

    We aimed to evaluate the physical imaging properties in various digital radiography systems with charged coupled device (CCD), computed radiography (CR), and indirect flat panel detector (FPD). The imaging properties measured in this study were modulation transfer function (MTF) wiener spectrum (WS), and detective quantum efficiency (DQE) to compare the performance of each digital radiography system. The system response of CCD were in a linear relationship with exposure and that of CR and FPD were proportional to the logarithm of exposure. The MTF of both CR and FPD indicated a similar tendency but in case of CCD, it showed lower MTF than that of CR and FPD. FPD showed the lowest WS and also indicated the highest DQE among three systems. According to the results, digital radiography system with different type of image receptor had its own image characteristics. Therefore, it is important to know the physical imaging characteristics of the digital radiography system accurately to obtain proper image quality.

  11. The work of ICRP on the ethical foundations of the system of radiological protection

    International Nuclear Information System (INIS)

    Cho, Kun-Woo

    2017-01-01

    The International Commission on Radiological Protection (ICRP) has established Task Group 94 (TG 94) to develop a publication on the ethical foundations of the system of radiological protection aiming to consolidate the basis of ICRP's recommendations, to improve the understanding of the system and to provide a basis for communication on radiation risk and its perception. Through the review of the publications of the Commission and the conduct of a series of workshops, TG 94 has identified the key components of the ethical theories and principles relevant to the system of radiological protection. The purpose of eliciting the ethical values underpinning the system of radiological protection is not only to clarify the rationale of the recommendations made by the Commission, but also to assist in discussions related to its practical implementation. The report nearing completion by TG 94 will present the key steps concerning the scientific, ethical and practical evolutions of the system of radiological protection since the first ICRP publication in 1928, describe the core ethical values underpinning the present system and address the key procedural aspects for its implementation. (authors)

  12. Radiology integration in a multi-hospital system.

    Science.gov (United States)

    Welch, D

    1999-01-01

    In 1989, Salt Lake City's Intermountain Health Care (IHC) began a process to reduce costs and streamline processes. Divided into four geographic regions, IHC consists of 24 hospitals and 100 clinics, a 400-member practitioner-physician group, and a staff of 23,000. IHC determined that three Salt Lake Valley hospitals, part of its Urban Central Region, must become one entity with shared management and a reduced staff to cover operations at all three hospitals. Management of the three radiology departments were charged with creating an integration process for the three hospitals. Two directors were selected to manage radiology and meet the outlined goals. Difficulty arose when one director needed to make changes in a facility managed by the other. The directors found that structuring by modality allowed them to plan for all three facilities, standardize equipment purchases and create integrated rather than departmental programs. As consolidation was taking place in top management, employees worried what the resulting changes meant for their jobs. Many were unfamiliar with the concepts of team structure and continuous quality improvement. Various courses and meetings were held to educate staff members and bring them up to new standards. Most successful were the meetings that allowed staff from different facilities to come together and share ideas. Although travel was an issue, these meetings quickly helped move the integration processes forward as peer relationships were developed. Employees were recruited for cross-training and new staff worked wherever needed. As they began to share data, the three hospitals identified best-practice and internal benchmarks. IHC is now ready to hire a single director to manage the radiology departments at the three Salt Lake Valley hospitals.

  13. Implications of science and technology on the radiological protection system

    International Nuclear Information System (INIS)

    Metivier, H.; LAZO, T.

    2006-01-01

    Full text of publication follows: The mission of the Nuclear Energy Agency (Nea) Committee on Radiation Protection and Public Health (C.R.P.P.H.) includes providing member -country governments with insight into evolving or emerging issues that could affect radiation protection policy, regulation or application. Although it can not be currently said that the scientific understanding of radiological risks has significantly changed recently, ongoing radio-biological and epidemiological research could challenge the conventional paradigm in the mid -term future. The C.R.P.P.H. finalized in March 2006 finalize a study of possible challenges and their implications. This study includes two principle areas: challenges arising from scientific developments; and, challenges to the implementation of radiation protection. This report updates the earlier C.R.P.P.H. report, 'Developments in Radiation Health Sciences and their Impact on Radiation Protection' (Nea 1998). Broadly speaking, ongoing radiation biology studies present the possibility that our current practice of summing various type s of exposures into a single value of effective dose is not scientifically supported because of significantly differing dose/response relationships (chronic vs. acute, internal vs. external, high Let versus low Let, etc.). In addition, non-targeted effects, and the possibility of individual hyper-sensitivity to radiation further challenge our current notion of the relationship between detriment and dose. Although there is no conclusive evidence for this at this time, the possible implications of such changes will be investigated to better prepare governments and the radiation protection community should sound scientific evidence emerge. In addition to these possible scientific challenges, the applications and events that would require radiological protection input are also evolving. In particular, the use of radiation in medicine, with new techniques and the spread of existing technologies

  14. Prototype of time digitizing system for BESⅢ endcap TOF upgrade

    International Nuclear Information System (INIS)

    Cao Ping; Sun Weijia; Fan Huanhuan; Wang Siyu; Liu Shubin; An Qi; Ji Xiaolu

    2014-01-01

    The prototype of a time digitizing system for the BESⅢ endcap TOF (ETOF) upgrade is introduced in this paper. The ETOF readout electronics has a distributed architecture. Hit signals from the multi-gap resistive plate chamber (MRPC) are signaled as LVDS by front-end electronics (FEE) and are then sent to the back-end time digitizing system via long shield differential twisted pair cables. The ETOF digitizing system consists of two VME crates, each of which contains modules for time digitization, clock, trigger, fast control, etc. The time digitizing module (TDIG) of this prototype can support up to 72 electrical channels for hit information measurement. The fast control (FCTL) module can operate in barrel or endcap mode. The barrel FCTL fans out fast control signals from the trigger system to the endcap FCTLs, merges data from the endcaps and then transfers to the trigger system. Without modifying the barrel TOF (BTOF) structure, this time digitizing architecture benefits from improved ETOF performance without degrading the BTOF performance. Lab experiments show that the time resolution of this digitizing system can be lower than 20 ps, and the data throughput to the DAQ can be about 92 Mbps. Beam experiments show that the total time resolution can be lower than 45 ps. (authors)

  15. Unattended digital video surveillance: A system prototype for EURATOM safeguards

    International Nuclear Information System (INIS)

    Chare, P.; Goerten, J.; Wagner, H.; Rodriguez, C.; Brown, J.E.

    1994-01-01

    Ever increasing capabilities in video and computer technology have changed the face of video surveillance. From yesterday's film and analog video tape-based systems, we now emerge into the digital era with surveillance systems capable of digital image processing, image analysis, decision control logic, and random data access features -- all of which provide greater versatility with the potential for increased effectiveness in video surveillance. Digital systems also offer other advantages such as the ability to ''compress'' data, providing increased storage capacities and the potential for allowing longer surveillance Periods. Remote surveillance and system to system communications are also a benefit that can be derived from digital surveillance systems. All of these features are extremely important in today's climate Of increasing safeguards activity and decreasing budgets -- Los Alamos National Laboratory's Safeguards Systems Group and the EURATOM Safeguards Directorate have teamed to design and implement a period surveillance system that will take advantage of the versatility of digital video for facility surveillance system that will take advantage of the versatility of digital video for facility surveillance and data review. In this Paper we will familiarize you with system components and features and report on progress in developmental areas such as image compression and region of interest processing

  16. REVIEW OF NRC APPROVED DIGITAL CONTROL SYSTEMS ANALYSIS

    International Nuclear Information System (INIS)

    Markman, D.W.

    1999-01-01

    Preliminary design concepts for the proposed Subsurface Repository at Yucca Mountain indicate extensive reliance on modern, computer-based, digital control technologies. The purpose of this analysis is to investigate the degree to which the U. S. Nuclear Regulatory Commission (NRC) has accepted and approved the use of digital control technology for safety-related applications within the nuclear power industry. This analysis reviews cases of existing digitally-based control systems that have been approved by the NRC. These cases can serve as precedence for using similar types of digitally-based control technologies within the Subsurface Repository. While it is anticipated that the Yucca Mountain Project (YMP) will not contain control systems as complex as those required for a nuclear power plant, the review of these existing NRC approved applications will provide the YMP with valuable insight into the NRCs review process and design expectations for safety-related digital control systems. According to the YMP Compliance Program Guidance, portions of various NUREGS, Regulatory Guidelines, and nuclear IEEE standards the nuclear power plant safety related concept would be applied to some of the designs on a case-by-case basis. This analysis will consider key design methods, capabilities, successes, and important limitations or problems of selected control systems that have been approved for use in the Nuclear Power industry. An additional purpose of this analysis is to provide background information in support of further development of design criteria for the YMP. The scope and primary objectives of this analysis are to: (1) Identify and research the extent and precedence of digital control and remotely operated systems approved by the NRC for the nuclear power industry. Help provide a basis for using and relying on digital technologies for nuclear related safety critical applications. (2) Identify the basic control architecture and methods of key digital control

  17. Systems and methods for self-synchronized digital sampling

    Science.gov (United States)

    Samson, Jr., John R. (Inventor)

    2008-01-01

    Systems and methods for self-synchronized data sampling are provided. In one embodiment, a system for capturing synchronous data samples is provided. The system includes an analog to digital converter adapted to capture signals from one or more sensors and convert the signals into a stream of digital data samples at a sampling frequency determined by a sampling control signal; and a synchronizer coupled to the analog to digital converter and adapted to receive a rotational frequency signal from a rotating machine, wherein the synchronizer is further adapted to generate the sampling control signal, and wherein the sampling control signal is based on the rotational frequency signal.

  18. Fully integrated digital GAMMA camera-computer system

    International Nuclear Information System (INIS)

    Berger, H.J.; Eisner, R.L.; Gober, A.; Plankey, M.; Fajman, W.

    1985-01-01

    Although most of the new non-nuclear imaging techniques are fully digital, there has been a reluctance in nuclear medicine to abandon traditional analog planar imaging in favor of digital acquisition and display. The authors evaluated a prototype digital camera system (GE STARCAM) in which all of the analog acquisition components are replaced by microprocessor controls and digital circuitry. To compare the relative effects of acquisition matrix size on image quality and to ascertain whether digital techniques could be used in place of analog imaging, Tc-99m bone scans were obtained on this digital system and on a comparable analog camera in 10 patients. The dedicated computer is used for camera setup including definition of the energy window, spatial energy correction, and spatial distortion correction. The display monitor, which is used for patient positioning and image analysis, is 512/sup 2/ non-interlaced, allowing high resolution imaging. Data acquisition and processing can be performed simultaneously. Thus, the development of a fully integrated digital camera-computer system with optimized display should allow routine utilization of non-analog studies in nuclear medicine and the ultimate establishment of fully digital nuclear imaging laboratories

  19. Circuit, especially for digital nuclear gyroscope systems

    International Nuclear Information System (INIS)

    Lowdenslager, J.R.

    1974-01-01

    The circuit with at least one or two spin generator shows a digital phase synchronizing loop in solid-state construction without movable mechanical parts. It is stable, may be turned in one direction any number of times without saturation, and also remains phase-synchronized when input signals are turned off. For this purpose, crystal oscillators with certain resonance frequencies are used. The spin generators are coupled at the outled side with filtering, squaring, and differential connections generating control impulses synchronous to the spin generators. Step divider circuits are connected to the oscillators, which act upon flip-flop registers. This is controlled by the filtering, squaring, and differential connections. Furthermore, field proportional control circuits with registers, advancing and delay circuits are provided, the registers being connected at the outlet side with digital adders and subtractors. The digital adder serves inertial-related purposes. (DG) [de

  20. Qualitative review of usability problems in health information systems for radiology.

    Science.gov (United States)

    Dias, Camila Rodrigues; Pereira, Marluce Rodrigues; Freire, André Pimenta

    2017-12-01

    Radiology processes are commonly supported by Radiology Information System (RIS), Picture Archiving and Communication System (PACS) and other software for radiology. However, these information technologies can present usability problems that affect the performance of radiologists and physicians, especially considering the complexity of the tasks involved. The purpose of this study was to extract, classify and analyze qualitatively the usability problems in PACS, RIS and other software for radiology. A systematic review was performed to extract usability problems reported in empirical usability studies in the literature. The usability problems were categorized as violations of Nielsen and Molich's usability heuristics. The qualitative analysis indicated the causes and the effects of the identified usability problems. From the 431 papers initially identified, 10 met the study criteria. The analysis of the papers identified 90 instances of usability problems, classified into categories corresponding to established usability heuristics. The five heuristics with the highest number of instances of usability problems were "Flexibility and efficiency of use", "Consistency and standards", "Match between system and the real world", "Recognition rather than recall" and "Help and documentation", respectively. These problems can make the interaction time consuming, causing delays in tasks, dissatisfaction, frustration, preventing users from enjoying all the benefits and functionalities of the system, as well as leading to more errors and difficulties in carrying out clinical analyses. Furthermore, the present paper showed a lack of studies performed on systems for radiology, especially usability evaluations using formal methods of evaluation involving the final users. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Regulatory requirements for replacement of analog systems with digital upgrades

    International Nuclear Information System (INIS)

    Loeser, P.J.

    1993-01-01

    This paper reviews briefly the regulatory guidelines which must be met in order to replace analog systems in nuclear power plants with digital systems. There is a move to do such replacements for a number of reasons: analog systems are aging, and showing considerable drift; few vendors manufacture analog systems today; support and parts are hard to get; digital systems provide flexibility. There is a safety concern however about undesirable and unpredictable effects to digital safety equipment due to plant transients, accidents, post-accident condition, and EMI/RF environmental interferences. License holders must comply with the requirements of 10 C.F.R. 50.59, which deals with safety concerns with respect to any changes to operating plants which may have an impact on the safety of the plant. NRC staff is taking the position that all digital upgrades will require an evaluation under this regulation

  2. Digital Voting Systems and Communication in Classroom Lectures

    DEFF Research Database (Denmark)

    Mathiasen, Helle

    2015-01-01

    Studies on the use of digital voting systems in large group teaching situations have often focused on the ”non-anonymity” and control and testing functions that the technology provides. There has also been some interest in how students might use their votes tactically to gain “credits”. By focusing...... on an empirical study of students’ experiences with digital voting systems in lectures at two Danish universities, this study considers the premises and the contexts surrounding this technology. It will also aim to show that for both instructors and students, digital voting systems are a much broader resource...... than simply a device for facilitating ”non-anonymity”, test, control and allocation of credits. The case studies showed, for instance, that digital voting systems can be conducive to a more open approach in which the systems are used as communication tools and teaching resources in situations where...

  3. Synchronisation Strategy in Complex Digital Voter-based Systems

    Directory of Open Access Journals (Sweden)

    SZÁSZ Csaba

    2017-10-01

    Full Text Available Researchers in microelectronics generally agree that reliability and computing power are the two most important factors for next generation digital systems. Redundancy techniques are implemented widely to increase the reliability and fault tolerance of these systems. In this paper a triple modular redundancy (TMR majority voter based fault-tolerant digital system architecture is presented and analyzed. The vast majority of researchers that design and implement such systems usually assume that in these configurations the voter operates perfectly while is not true. This presentation outlines a specific situation when under same conditions the digital voter is exposed to misleading operation generating wrong information on its output. To overcome such situations there a versatile method has been proposed and implemented that is well suited to overcome the improper operation of TMR structures. The experimental results prove the theoretical assumptions and validate the initial expectations regarding the considered digital system fault-tolerant operation.

  4. Digital terrestrial television broadcasting technology and system

    CERN Document Server

    2015-01-01

    Now under massive deployment worldwide, digital terrestrial television broadcasting (DTTB) offers one of the most attractive ways to deliver digital TV over the VHF/UHF band. Written by a team of experts for specialists and non-specialists alike, this book serves as a comprehensive guide to DTTB. It covers the fundamentals of channel coding and modulation technologies used in DTTB, as well as receiver technology for synchronization, channel estimation, and equalization. It also covers the recently introduced Chinese DTTB standard, using the SFN network in Hong Kong as an example.

  5. Evaluation of the field size in dental diagnostic radiology system

    International Nuclear Information System (INIS)

    Andrade, P.S.; Potiens, M.P.A.

    2006-01-01

    In this work the field size of a dental X rays machine was evaluated considering the recommendation of the Brazilian Health Ministry Regulation 453 which established basic lines of radiological protection in medical and dental diagnostic radiology. The diameter of the field should not be superior to 6 cm in the localized end point, limiting the radiated area and protecting the head-neck region. The measurements were carried out in a dental X rays machine, Dabi Atlante, model Spectro 70X Seletronic. For the field size or useful beam determination, the intra-oral films were positioned on a plain surface to be exposed in four stages and two focus-film distances (FFD), 20 cm and 27.5 cm: 1) with spacer cone; 2) without spacer cone; 3) with spacer cone and film-holding device; 4) without spacer cone and film-holding device. The results show that the diameter of the field size is satisfactory only for FFD = 20 cm. When the film-holding device is used, which is recommended by the Regulation 453, item 5.8 d(ii), the diameter of the field size exceeds the maximum recommended value of 6 cm. (authors)

  6. Data Fusion for a Vision-Radiological System: a Statistical Calibration Algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Enqvist, Andreas; Koppal, Sanjeev; Riley, Phillip [University of Florida, Gainesville, FL 32611 (United States)

    2015-07-01

    Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development of calibration algorithms for characterizing the fused sensor system as a single entity. There is an apparent need for correcting for a scene deviation from the basic inverse distance-squared law governing the detection rates even when evaluating system calibration algorithms. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked, to which the time-dependent radiological data can be incorporated by means of data fusion of the two sensors' output data. (authors)

  7. Data Fusion for a Vision-Radiological System: a Statistical Calibration Algorithm

    International Nuclear Information System (INIS)

    Enqvist, Andreas; Koppal, Sanjeev; Riley, Phillip

    2015-01-01

    Presented here is a fusion system based on simple, low-cost computer vision and radiological sensors for tracking of multiple objects and identifying potential radiological materials being transported or shipped. The main focus of this work is the development of calibration algorithms for characterizing the fused sensor system as a single entity. There is an apparent need for correcting for a scene deviation from the basic inverse distance-squared law governing the detection rates even when evaluating system calibration algorithms. In particular, the computer vision system enables a map of distance-dependence of the sources being tracked, to which the time-dependent radiological data can be incorporated by means of data fusion of the two sensors' output data. (authors)

  8. Systems of imaging digital systems in case of glaucoma

    International Nuclear Information System (INIS)

    Fernandez Argones, Liamet; Piloto Diaz, Ibrain; Coba Penna, Maria Josefa; Perez Tamayo, Bertila; Dominguez Randulfe, Marerneda; Trujillo Fonseca, Katia

    2009-01-01

    Now a day we can't consider the strict follow up in Glaucoma without the use of the digital analysis of image system of the optic nerve head and the retinal nerve fiber layer. This is a review about some contributions of Scanning Laser Polarimetry (GDx VCC, Carl Zeiss Meditec, Dublin, CA), Confocal Scanning Laser (Heidelberg Retina Tomograph HRT, Heidelberg Engineering Inc.) and Optical Coherence Tomography (Stratus OCT, Carl Zeiss Meditec, Alemania) in the diagnosis and follow up of Glaucoma. It's considered that objective measurement giving by them must be incorporate in the rigorous analysis of each glaucomatous patient

  9. Automatic digital photo-book making system

    Science.gov (United States)

    Wang, Wiley; Teo, Patrick; Muzzolini, Russ

    2010-02-01

    The diversity of photo products has grown more than ever before. A group of photos are not only printed individually, but also can be arranged in specific order to tell a story, such as in a photo book, a calendar or a poster collage. Similar to making a traditional scrapbook, digital photo book tools allow the user to choose a book style/theme, layouts of pages, backgrounds and the way the pictures are arranged. This process is often time consuming to users, given the number of images and the choices of layout/background combinations. In this paper, we developed a system to automatically generate photo books with only a few initial selections required. The system utilizes time stamps, color indices, orientations and other image properties to best fit pictures into a final photo book. The common way of telling a story is to lay the pictures out in chronological order. If the pictures are proximate in time, they will coincide with each other and are often logically related. The pictures are naturally clustered along a time line. Breaks between clusters can be used as a guide to separate pages or spreads, thus, pictures that are logically related can stay close on the same page or spread. When people are making a photo book, it is helpful to start with chronologically grouped images, but time alone wont be enough to complete the process. Each page is limited by the number of layouts available. Many aesthetic rules also apply, such as, emphasis of preferred pictures, consistency of local image density throughout the whole book, matching a background to the content of the images, and the variety of adjacent page layouts. We developed an algorithm to group images onto pages under the constraints of aesthetic rules. We also apply content analysis based on the color and blurriness of each picture, to match backgrounds and to adjust page layouts. Some of our aesthetic rules are fixed and given by designers. Other aesthetic rules are statistic models trained by using

  10. Impacto de la radiología digital en la dosis de referencia de radiología intraoral española

    OpenAIRE

    Velasco Hidalgo, Francisco

    2016-01-01

    INTRODUCCION: las dosis de referencia (DRLs) son los niveles de dosis administradas a los pacientes en exposiciones de radiodiagnóstico médico que no deben sobrepasarse y pueden ser utilizados como indicadores en los procesos de optimización radiológica. A raíz de las publicaciones iniciales para reducir las dosis de radiación en los EE.UU. En odontología, se incluyen estas recomendaciones en las directrices europeas sobre protección radiológica en radiología dental; sin embargo, hemos encont...

  11. Classification of radiological procedures

    International Nuclear Information System (INIS)

    1989-01-01

    A classification for departments in Danish hospitals which use radiological procedures. The classification codes consist of 4 digits, where the first 2 are the codes for the main groups. The first digit represents the procedure's topographical object and the second the techniques. The last 2 digits describe individual procedures. (CLS)

  12. [Digital imaging system are rapidly introduced in Swedish departments of radiography. This calls for new strategic planning].

    Science.gov (United States)

    Laurin, S; Norberg, K A

    2000-10-11

    Diagnostic radiology in Sweden is changing rapidly to digital (filmless) technique. The advantages are more rapid delivery of radiologic service, better working conditions and less negative effects on the environment. Teleradiology is also facilitated. The Swedish Board of Health and Welfare has investigated the speed with which this change is taking place. In 1998, 26 of the 118 departments of diagnostic radiology had already turned digital; it is estimated that in the near future at least five departments will become fully digital each year. For planning purposes, less emphasis should be put on the supply of radiographic film, and more on telecommunications, computer hardware and digital storage.

  13. Design of digital systems and devices

    CERN Document Server

    Adamski, Marian; Wegrzyn, Marek

    2011-01-01

    This book includes a variety of design and test methods targeted on different digital devices, as well as different logic elements. The authors of the book represent such countries as Israel, Poland, Russia, and Ukraine. The book is divided by three main parts, including thirteen different Chapters.

  14. Digital Watermark Tracking using Intelligent Multi-Agents System

    Directory of Open Access Journals (Sweden)

    Nagaraj V. DHARWADKAR

    2010-01-01

    Full Text Available E-commerce has become a huge business and adriving factor in the development of the Internet. Onlineshopping services are well established. Due to the evolution of2G and 3G mobile networks, soon online shopping services arecomplemented by their wireless counterparts. Furthermore, inthe recent years online delivery of digital media, such as MP3audio or video or image is very popular and will become anincreasingly important part of E-commerce. The advantage ofinternet is sharing the valuable digital data which lead to misuseof digital data. To resolve the problem of misuse of digital dataon Internet we need to have strong Digital rights monitoringsystem. Digital Rights Management (DRM is fairly youngdiscipline, while some of its underlying technologies have beenknown from many years. The use of DRM for managing andprotecting intellectual property rights is a comparatively newfield. In this paper we propose a model for online digital imagelibrary copyright protection based on watermark trackingSystem.In our proposed model the tracking of watermarks onremote host nodes is done using active mobile agents. The multiagentsystem architecture is used in watermark tracking whichsupports the coordination of several component tasks acrossdistributed and flexible networks of information sources.Whereas a centralized system is susceptible to system-widefailures and processing bottlenecks, multi-agent systems aremore reliable, especially given the likelihood of individualcomponent failures.

  15. Adoption of digital safety protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Z.

    1998-01-01

    The application of micro-processor-based digital controllers has been widely propagated among various industries in recent years. While in the nuclear power plant industry, the application of them has also been expanding gradually starting from non-safety related systems, taking advantage of their reliability and maintainability over the conventional analog devices. Based on the careful study of the feasibility of digital controllers to the safety protection system, the Tokyo Electric Power Company proposed on May 1989 the adoption of digital controllers to the safety protection system in the Application for Permission of Establishment of Kashiwazaki-Kariwa units 6 and 7 (ABWR-1350Mwe each). MITI, Ministry of International Trade and Industry, the Japanese regulatory body for electric power generating facilities, had approved this application after careful review. This paper describes a series of supporting activities leading to the MITI's approval of the digital safety protection system and the MITI's licensing activities. (author)

  16. Reliability analysis of digital safety systems at nuclear power plants

    International Nuclear Information System (INIS)

    Sopira Vladimir; Kovacs, Zoltan

    2015-01-01

    Reliability analysis of digital reactor protection systems built on the basis of TELEPERM XS is described, and experience gained by the Slovak RELKO company during the past 20 years in this domain is highlighted. (orig.)

  17. Enhanced digital library system that supports sustainable knowledge

    African Journals Online (AJOL)

    Enhanced digital library system that supports sustainable knowledge: A focus ... This research work provides a Web-Based University library, ability to access the ... and generates pins to authorize bonafide students and staff of the University.

  18. Digital signal processing in power system protection and control

    CERN Document Server

    Rebizant, Waldemar; Wiszniewski, Andrzej

    2011-01-01

    Digital Signal Processing in Power System Protection and Control bridges the gap between the theory of protection and control and the practical applications of protection equipment. Understanding how protection functions is crucial not only for equipment developers and manufacturers, but also for their users who need to install, set and operate the protection devices in an appropriate manner. After introductory chapters related to protection technology and functions, Digital Signal Processing in Power System Protection and Control presents the digital algorithms for signal filtering, followed

  19. Image Acquisition and Quality in Digital Radiography.

    Science.gov (United States)

    Alexander, Shannon

    2016-09-01

    Medical imaging has undergone dramatic changes and technological breakthroughs since the introduction of digital radiography. This article presents information on the development of digital radiography and types of digital radiography systems. Aspects of image quality and radiation exposure control are highlighted as well. In addition, the article includes related workplace changes and medicolegal considerations in the digital radiography environment. ©2016 American Society of Radiologic Technologists.

  20. Digitization

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2014-01-01

    what a concept of digital media might add to the understanding of processes of mediatization and what the concept of mediatization might add to the understanding of digital media. It is argued that digital media open an array of new trajectories in human communication, trajectories which were...

  1. Image quality of a Konica Regius 336 digital system in chest radiography

    International Nuclear Information System (INIS)

    Ostinelli, A.; Frigerio, M.; Monti, A.F.; Gelosa, S.; Tognoli, P.; Perniola, N.; Gozzi, G.

    2000-01-01

    Digital radiographic systems permit to optimize execution, depiction and storage of radiological images. Since a Regius 336 digital system (Konica Corp. Tokyo, Japan) devoted to chest radiography Department of S. Anna Hospital in Como, Italy, it was investigated its performance relative to image quality. Konica Regius 336 is a computed radiography system made of a phosphorescence detector plate which is scanned with an infrared semiconductor laser beam. The radiographic image obtained from the detector is subjected to image processing, which allows a stable output and the nonlinear curve typical of conventional radiographic systems. Image quality was assessed based on the following parameters: dose, contrast, noise and spatial resolution. As reference, it was assessed the same parameters on a Cronex 88 analogic chest-changer (DuPont Pharma, North Billerica, Mass, USA). The Regius 336 air kerma values were always higher than the analogic ones (about 10%), both with and without a chest phantom; noise was also greater than in analogic images, sometimes even doubled. The optical densities of a step wedge and the spatial resolution of the digital chest-changer are independent of the X-ray tube voltage consequent to broader optical latitude. Inversely, the analogic images of the wedges show great optical density variability as a function of the X-ray tube voltage (in a range of 2). The modulation transfer functions of the two systems have the same trend. The performance of the Konica Regius 336 is nearly equivalent to that of an analogic system. The main advantages of the digital system are a standard output, lower consumption of radiographic films, higher productiveness and better image quality standard level [it

  2. GESCOM: system for commercial management of radiological protection services

    International Nuclear Information System (INIS)

    Alonso Abad, Dolores; Simon Rodriguez, Carmen; Proenza Suarez, Emma

    2008-01-01

    A wide range of Radiological protection services of national reach are offered by the Center for Radiation Protection and Hygiene (CPHR). The software developed enlarges the possibilities of the commercial management of these services. It contains all information generated in the interaction as much with the client as with the specialists during the process of realization of these services, impregnating them an added value and contributing to increase the quality and the efficiency of the commercial management of the organization. GESCOM has a wide group of reports which offer clear and precise information. It contains general modules such as entities, services request and services contract. It has specific modules for the most complex services: external dosimetry, calibration and/or verification of dose equipment, internal contamination and measurement of samples. (author)

  3. Applying Systems Engineering Reduces Radiology Transport Cycle Times in the Emergency Department

    Science.gov (United States)

    White, Benjamin A.; Yun, Brian J.; Lev, Michael H.; Raja, Ali S.

    2017-01-01

    Introduction Emergency department (ED) crowding is widespread, and can result in care delays, medical errors, increased costs, and decreased patient satisfaction. Simultaneously, while capacity constraints on EDs are worsening, contributing factors such as patient volume and inpatient bed capacity are often outside the influence of ED administrators. Therefore, systems engineering approaches that improve throughput and reduce waste may hold the most readily available gains. Decreasing radiology turnaround times improves ED patient throughput and decreases patient waiting time. We sought to investigate the impact of systems engineering science targeting ED radiology transport delays and determine the most effective techniques. Methods This prospective, before-and-after analysis of radiology process flow improvements in an academic hospital ED was exempt from institutional review board review as a quality improvement initiative. We hypothesized that reorganization of radiology transport would improve radiology cycle time and reduce waste. The intervention included systems engineering science-based reorganization of ED radiology transport processes, largely using Lean methodologies, and adding no resources. The primary outcome was average transport time between study order and complete time. All patients presenting between 8/2013–3/2016 and requiring plain film imaging were included. We analyzed electronic medical record data using Microsoft Excel and SAS version 9.4, and we used a two-sample t-test to compare data from the pre- and post-intervention periods. Results Following the intervention, average transport time decreased significantly and sustainably. Average radiology transport time was 28.7 ± 4.2 minutes during the three months pre-intervention. It was reduced by 15% in the first three months (4.4 minutes [95% confidence interval [CI] 1.5–7.3]; to 24.3 ± 3.3 min, P=0.021), 19% in the following six months (5.4 minutes, 95% CI [2.7–8.2]; to 23.3 ± 3

  4. Contribution of the french society of radiological protection to the current reflections on the possible improvement of the radiological risk management system

    International Nuclear Information System (INIS)

    Lecomte, J.F.; Schieber, C.

    2000-01-01

    Following the invitation by IRPA to comment the article by Prof. R. Clarke entitled 'Control of Low Level Radiation Exposures: Time for a Change?', the Board of the French Radiological Protection Society (SFRP) has decided to set up a specific Working Group. This Group consists of some twenty members representing the stakeholders involved in radiological protection in France. Its goal is, starting from an analysis of R. Clarke's text, to formulate questions and proposals to assist ICRP in making its radiological protection system more understandable and more efficient. The aim of this review is not to restart from scratch but to consolidate and improve the existing system. The Working Group has therefore focused its thoughts on the following four points: 1. The basis of the radiological risk management system. In the absence of scientific certainty as to the effects of low doses of radiation, a prudent attitude has been adopted as to the manner of managing the radiological risk, based on the hypothesis that the dose-effect relationship is linear with no threshold. The Group discusses this basic assumption and its implications on the elaboration of the objectives of the radiological risk management system. 2. Exposure situations. Exposure situations are multifarious and the existing system divides them into categories for management purpose (e.g. practice/intervention; natural/artificial; medical/public/occupational; actual exposure/potential exposure; etc.). Some of these divisions are pertinent but some are less so and the Group examines if another way of conceptualising exposures situations could be more efficient. 3. Risk management indicators and tools. The radiological protection system provides the professionals with a series of indicators and tools, enabling them to manage exposure situations (dose, dose limit, dose constraint, individual dose, collective dose, investigation level, action level, interventional level, exemption level, clearance level

  5. New around-the-clock radiology coverage system for the emergency department: a satisfaction survey among clinicians

    International Nuclear Information System (INIS)

    Choi, Young Hun; Jae, Hwan Jun; Shin, Cheong Il; Song, Su Jin; Cha, Won Cheol; Na, Dong Gyu

    2008-01-01

    The purpose of this study was to assess the clinician satisfaction of a newly introduced around-the-clock radiology coverage system for the emergency department. Seventeen emergency physicians (8 board certified physicians, 9 residents) were invited to fill out a survey pertaining to the newly introduced radiology coverage system for the emergency department. The questionnaire included 10 questions covering three major topics. The first topic related to the around-the-clock radiology coverage by two full-time radiology residents. The second topic focused on the preliminary interpretations of radiology residents. The last topic included the interpretation assistance system by board-certified radiologists. The answers to each question were assessed using a scoring system of 1 to 5. The mean satisfaction score of the around-the-clock radiology coverage system by the two full-time radiology residents was 4.6 (range 3-5). The mean score for the preliminary interpretation system by the radiology residents was 4.8 (range 4-5). The score for the reliability of the preliminary versus the final interpretation was 4.1 (range 4-5). Lastly, the mean score for the interpretation assistance system by board-certified radiologists was 4.9 (range 4-5). The results of this study indicate a high satisfaction rating among clinicians' of the new around-the-clock radiology coverage system for the emergency department

  6. Digital Blood Flow In Systemic Lupus Erythematosus By Photoplethysmography

    Directory of Open Access Journals (Sweden)

    Ghosh Sanjay

    2002-01-01

    Full Text Available Digital vascular status in 10 patients of systemic lupus erythematous (SLE suffering for 1 to 5 years and 5 control (normal subjects was assessed by a highly sensitive, non-invasive technique called photoplethysmography (PPG. Six patients (Group A showed clinical sign. PPG recordings were done by applying the PPG probe serially to the distal phalanges of all the digits of four limbs with Velcro-strap at an ambient temperature of 27 to 31C and humidity 60 to 65% Diminished capillary flow. On average, 12 digits (60% in Group A and 8 digits (40% in group B patients showed reduced blood circulation. Degree of vascular impairment had no bearing upon the duration of the disease. The PPG has objectively shown digital vascular impairment in all SLE patients having no correlation with the extent of clinical manifestations and the duration of the disease.

  7. Localization of equipment for digital plant protection system

    Energy Technology Data Exchange (ETDEWEB)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed.

  8. Localization of equipment for digital plant protection system

    International Nuclear Information System (INIS)

    Koo, I. S.; Park, H. Y.; Lee, C. K. and others

    2000-10-01

    The objective of this project lies on the development of design requirements, establishment of structure and manufacture procedures, development of the software verification and validation(V and V) techniques of the digital plant protection system. The functional requirements based on the analog protection system and digital design requirements are introduced, the processor and system bus for safety grade equipment are selected and the interface requirements and the design specification have been developed in order to manufacture the quick prototype of the digital plant protection system. The selection guidelines of parts, software development and coding and testing for digital plant protection system have been performed through manufacturing the quick prototype based on the developed design specification. For the software verification and validation, the software review plan and techniques of verification and validation have been researched. The digital validation system is developed in order to verify the quick prototype. The digital design requirements are reviewed by the software safety plan and V and V plans. The formal methods for verifying the safety-grade software are researched, then the methodology of formal analysis and testing have been developed

  9. System for objective assessment of image differences in digital cinema

    Science.gov (United States)

    Fliegel, Karel; Krasula, Lukáš; Páta, Petr; Myslík, Jiří; Pecák, Josef; Jícha, Marek

    2014-09-01

    There is high demand for quick digitization and subsequent image restoration of archived film records. Digitization is very urgent in many cases because various invaluable pieces of cultural heritage are stored on aging media. Only selected records can be reconstructed perfectly using painstaking manual or semi-automatic procedures. This paper aims to answer the question what are the quality requirements on the restoration process in order to obtain acceptably close visual perception of the digitally restored film in comparison to the original analog film copy. This knowledge is very important to preserve the original artistic intention of the movie producers. Subjective experiment with artificially distorted images has been conducted in order to answer the question what is the visual impact of common image distortions in digital cinema. Typical color and contrast distortions were introduced and test images were presented to viewers using digital projector. Based on the outcome of this subjective evaluation a system for objective assessment of image distortions has been developed and its performance tested. The system utilizes calibrated digital single-lens reflex camera and subsequent analysis of suitable features of images captured from the projection screen. The evaluation of captured image data has been optimized in order to obtain predicted differences between the reference and distorted images while achieving high correlation with the results of subjective assessment. The system can be used to objectively determine the difference between analog film and digital cinema images on the projection screen.

  10. Quasiinvariant Automatic Control Digital Systems of Inertia Objects

    OpenAIRE

    Lvov, Volodymyr; Andrieiev, Anatoliy

    2010-01-01

    The two-connected automatic control digital system (ACDS) and system of ACDS with combined control are examined. The two-connected and combined system of ACDS with work in the mode of tracking and stabilizing are analyzed. The discrete transfer function of two-connected and combined systems are obtained.

  11. Intermediate probabilistic safety assessment approach for safety critical digital systems

    International Nuclear Information System (INIS)

    Taeyong, Sung; Hyun Gook, Kang

    2001-01-01

    Even though the conventional probabilistic safety assessment methods are immature for applying to microprocessor-based digital systems, practical needs force to apply it. In the Korea, UCN 5 and 6 units are being constructed and Korean Next Generation Reactor is being designed using the digital instrumentation and control equipment for the safety related functions. Korean regulatory body requires probabilistic safety assessment. This paper analyzes the difficulties on the assessment of digital systems and suggests an intermediate framework for evaluating their safety using fault tree models. The framework deals with several important characteristics of digital systems including software modules and fault-tolerant features. We expect that the analysis result will provide valuable design feedback. (authors)

  12. Focal role of tolerability and reasonableness in the radiological protection system.

    Science.gov (United States)

    Schneider, T; Lochard, J; Vaillant, L

    2016-06-01

    The concepts of tolerability and reasonableness are at the core of the International Commission on Radiological Protection (ICRP) system of radiological protection. Tolerability allows the definition of boundaries for implementing ICRP principles, while reasonableness contributes to decisions regarding adequate levels of protection, taking into account the prevailing circumstances. In the 1970s and 1980s, attempts to find theoretical foundations in risk comparisons for tolerability and cost-benefit analysis for reasonableness failed. In practice, the search for a rational basis for these concepts will never end. Making a wise decision will always remain a matter of judgement and will depend on the circumstances as well as the current knowledge and past experience. This paper discusses the constituents of tolerability and reasonableness at the heart of the radiological protection system. It also emphasises the increasing role of stakeholder engagement in the quest for tolerability and reasonableness since Publication 103. © The International Society for Prosthetics and Orthotics.

  13. The application of geographic information system to radiological and nuclear emergency monitoring

    International Nuclear Information System (INIS)

    Sadaniowski, I.V.; Rodriguez, M.; Rojas, C.A.; Jordan, O.D.

    2010-01-01

    The Geographic Information System (GIS) implementation for the preparation and response in case of to radiological and nuclear emergencies is being developed in the Emergency Control Center of the Argentina Nuclear Regulatory Authority, since many years ago. Additionals features have been incorporated such as integration with the results of radiological monitoring, improving and expanding its benefits both in the preparation stage and during the work of emergency response. This paper shows the specific application of GIS to radiological monitoring in case of emergency situations such as during the search of orphan sources and the characterization of geographic context around nuclear power plants and atomic centers. The GIS provides essential data cartographic for the monitoring with sophisticated detectors, to integrate with the information received with infrastructure, urban and rural population maps, physical features of the place, satellite images, etc. The monitoring results are analyzed and compared with relevant information for decision making during the response, like evacuation routes, affected population, security forces in the area, radiological characterization, application of protective actions, hospitals, schools, etc. These two integrated tools improve preparedness and response system in case of radiological or nuclear emergency. (authors) [es

  14. Software V ampersand V methods for digital plant protection system

    International Nuclear Information System (INIS)

    Kim, Hung-Jun; Han, Jai-Bok; Chun, Chong-Son; Kim, Sung; Kim, Kern-Joong.

    1997-01-01

    Careful thought must be given to software design in the development of digital based systems that play a critical role in the successful operation of nuclear power plants. To evaluate the software verification and validation methods as well as to verify its system performance capabilities for the upgrade instrumentation and control system in the Korean future nuclear power plants, the prototype Digital Plant, Protection System (DPPS) based on the Programmable Logic Controller (PLC) has been constructed. The system design description and features are briefly presented, and the software design and software verification and validation methods are focused. 6 refs., 2 figs

  15. A presentation system for just-in-time learning in radiology.

    Science.gov (United States)

    Kahn, Charles E; Santos, Amadeu; Thao, Cheng; Rock, Jayson J; Nagy, Paul G; Ehlers, Kevin C

    2007-03-01

    There is growing interest in bringing medical educational materials to the point of care. We sought to develop a system for just-in-time learning in radiology. A database of 34 learning modules was derived from previously published journal articles. Learning objectives were specified for each module, and multiple-choice test items were created. A web-based system-called TEMPO-was developed to allow radiologists to select and view the learning modules. Web services were used to exchange clinical context information between TEMPO and the simulated radiology work station. Preliminary evaluation was conducted using the System Usability Scale (SUS) questionnaire. TEMPO identified learning modules that were relevant to the age, sex, imaging modality, and body part or organ system of the patient being viewed by the radiologist on the simulated clinical work station. Users expressed a high degree of satisfaction with the system's design and user interface. TEMPO enables just-in-time learning in radiology, and can be extended to create a fully functional learning management system for point-of-care learning in radiology.

  16. BNL ALARA Center's development of a computerized radiological assessment and design system (RADS)

    International Nuclear Information System (INIS)

    Dionne, B.J.; Masciulli, S.; Connelly, J.M.

    1993-01-01

    The US Department of Energy's (DOE) Office of Health Physics and Industrial Hygiene sponsored a study of Radiological Engineering Programs at selected DOE contractor facilities. This study was conducted to review, evaluate, and summarize techniques and practices that should be considered in the design phase that reduce dose and the spread of radioactive materials during subsequent construction and operation of DOE radiological facilities. As in a previous study on operational ALARA programs, a variety of good-practice documents will be generated. It is envisioned that these documents will serve as a resource to assist radiological engineers in the process of designing radiological facilities, and in performing radiological safety/ALARA design reviews. This paper presents the features for three good-practice documents and related software applications that are being developed based on the findings of this study. The proposed software called Radiological Assessment and Design System (RADS) will be a menu-driven database and spreadsheet program. It will be designed to provide easy, consistent, and effective implementation of the methodologies described in the three good-practice documents. These documents and the associated RADS software will provide the user with the following three functions: (1) enter dose assessment information and data into computer worksheets and provide printed tables of the results which can then be inserted into safety analysis reports or cost-benefit analyses, (2) perform a wide variety of sorts of radiological design criteria from DOE Orders and produce a checklist of the desired design criteria, and (3) enter cost/benefit data and qualitative rating of attributes for various design alternatives which reduce dose into computer worksheets and provide printed reports of cost-effectiveness results

  17. Human factors issues in digital system design and implementation

    International Nuclear Information System (INIS)

    Galletti, Greg S.

    1998-01-01

    A goal of the U.S. Nuclear Regulatory Commission (NRC) is to ensure safety in the application of digital equipment upgrades to nuclear power plant control rooms and local control stations. One of the areas of specific interest is the integration of digital technology into existing analog control, display, and information systems and the implications of such integration for operators in regard to their use of this new equipment to safely operate the plant. This paper is a discussion of human performance issues related to the introduction of such digital equipment into operating nuclear power plants. (author)

  18. Digital microwave communication engineering point-to-point microwave systems

    CERN Document Server

    Kizer, George

    2013-01-01

    The first book to cover all engineering aspects of microwave communication path design for the digital age Fixed point-to-point microwave systems provide moderate-capacity digital transmission between well-defined locations. Most popular in situations where fiber optics or satellite communication is impractical, it is commonly used for cellular or PCS site interconnectivity where digital connectivity is needed but not economically available from other sources, and in private networks where reliability is most important. Until now, no book has adequately treated all en

  19. Interventional Radiological Management of Prehepatic Obstruction the Splanchnic Venous System

    International Nuclear Information System (INIS)

    Semiz-Oysu, Aslihan; Keussen, Inger; Cwikiel, Wojciech

    2007-01-01

    Purpose. The purpose of this study was to retrospectively evaluate interventional radiological management of patients with symptomatic portal hypertension secondary to obstruction of splanchnic veins. Material and Methods. Twenty-four patients, 15 males and 9 females, 0.75 to 79 years old (mean, 36.4 years), with symptomatic portal hypertension, secondary to splanchnic venous obstruction, were treated by percutaneous methods. Causes and extent of splanchnic venous obstruction and methods are summarized following a retrospective evaluation. Results. Obstructions were localized to the main portal vein (n = 22), intrahepatic portal veins (n = 8), splenic vein (n = 4), and/or mesenteric veins (n = 4). Interventional treatment of 22 (92%) patients included recanalization (n = 19), pharmacological thrombolysis (n = 1), and mechanical thrombectomy (n = 5). Partial embolization of the spleen was done in five patients, in two of them as the only possible treatment. TIPS placement was necessary in 10 patients, while an existing occluded TIPS was revised in two patients. Transhepatic embolization of varices was performed in one patient, and transfemoral embolization of splenorenal shunt was performed in another. Thirty-day mortality was 13.6% (n=3). During the follow-up, ranging between 2 days and 58 months, revision was necessary in five patients. An immediate improvement of presenting symptoms was achieved in 20 patients (83%). Conclusion. We conclude that interventional procedures can be successfully performed in the majority of patients with obstruction of splanchnic veins, with subsequent improvement of symptoms. Treatment should be customized according to the site and nature of obstruction

  20. Radiology today. Volume 4

    International Nuclear Information System (INIS)

    Heuck, F.H.W.; Donner, M.W.

    1987-01-01

    The book discusses the following contents: Advances in Cardiovascular Imaging: Digital Arteriography: Ongoing Developments. Magnetic Resonance Imaging of the Cardiovascular System. Comparison of Vascular CT and MRI. Characterization of Vascular Lesions by Ultrasound - Progress in Vascular Interventions: Laser Angioplasty: A Review. Fibrinolytic Therapy Combined with Clot Extraction. Drugs Useful in Angioplasty. Developments in Cardiovascular Imaging: Blood Flow Measurements with Digital Arteriography. Selection of Imaging Techniques for Venous Thromboembolic Disease. Clinical Usefulness of High-Verus Low-Osmolality Contrast Agents. Developments in Angiographic and Interventional Instrumentation. Progress in Cardiovascular Interventions. Inferior Vena Cava Filters: Types, Placement, and Efficiency. Transluminal Vascular Stenting and Grafting. Venography and Sclerotherapy of Varioceles in Children and Adolescents. A New Catheter System - Important Hip Problems: Radiologic and Pathologic Correlation and Hip Disease. Comparison of Imaging Modalities in Femoral Head Necrosis. Osteoartrosis and Arthritis (Synovitis) of the Hip. Hip Anthrography

  1. MRI-based radiologic scoring system for extent of brain injury in children with hemiplegia.

    Science.gov (United States)

    Shiran, S I; Weinstein, M; Sirota-Cohen, C; Myers, V; Ben Bashat, D; Fattal-Valevski, A; Green, D; Schertz, M

    2014-12-01

    Brain MR imaging is recommended in children with cerebral palsy. Descriptions of MR imaging findings lack uniformity, due to the absence of a validated quantitative approach. We developed a quantitative scoring method for brain injury based on anatomic MR imaging and examined the reliability and validity in correlation to motor function in children with hemiplegia. Twenty-seven children with hemiplegia underwent MR imaging (T1, T2-weighted sequences, DTI) and motor assessment (Manual Ability Classification System, Gross Motor Functional Classification System, Assisting Hand Assessment, Jebsen Taylor Test of Hand Function, and Children's Hand Experience Questionnaire). A scoring system devised in our center was applied to all scans. Radiologic score covered 4 domains: number of affected lobes, volume and type of white matter injury, extent of gray matter damage, and major white matter tract injury. Inter- and intrarater reliability was evaluated and the relationship between radiologic score and motor assessments determined. Mean total radiologic score was 11.3 ± 4.5 (range 4-18). Good inter- (ρ = 0.909, P classification systems (ρ = 0.708, P high inter- and intrarater reliability and significant associations with manual ability classification systems and motor evaluations. This score provides a standardized radiologic assessment of brain injury extent in hemiplegic patients with predominantly unilateral injury, allowing comparison between groups, and providing an additional tool for counseling families. © 2014 by American Journal of Neuroradiology.

  2. Expanding a digital content management system for the growing digital media enterprise

    CERN Document Server

    Arthur, Magan H

    2013-01-01

    Building large integrated content management systems is a daunting task and there is little guidance for the implementation process for the mid-level manager. There are thousands of home grown or old standalone systems in need of upgrading and expanding to keep up with the growing challenge of digital media. This book allows the non-technical executive to understand the key concepts and issues. It covers the technical process and business aspects of expanding a system.

  3. Combating obsolescence - ACR digital control systems design

    International Nuclear Information System (INIS)

    Tikku, S.; Raiskums, G.

    2006-01-01

    The ever increasing use of digital technologies and products to meet the control, automation and monitoring needs of the nuclear power plant - even though justified by the benefits it provides - comes with an increased risk of technological obsolescence happening through the course of the plant life. Some well considered strategies are being employed in the ACR design process to minimise this risk and alleviate the consequence if it happens. These include application of a modular overall architecture, adoption of international widely accepted standards to harmonise equipment qualification and software practices, production of control functional specifications that are not influenced by target platform, and careful selection of technologies and products. (author)

  4. NRC perspectives on the digital system review process

    International Nuclear Information System (INIS)

    Mauck, J.L.

    1998-01-01

    Since about 1988, the USNRC has been involved in the review of digital retrofits to instrumentation and control (I and C) systems in nuclear power plants. Initially, this involvement was limited but with the advent of the 1990s, NRC involvement has become greater because of increased interest in and application of digital systems as existing analog systems become obsolete. Criteria for the design of such systems to ensure safety has been promulgated over the years and the USNRC has been actively involved both nationally and internationally with this effort. With the publication of the Zion Eagle 21 Safety Evaluation Report in 1992, Generic Letter 95-02 in April 1995 which endorses EPRI guidance document TR-102348 on digital upgrades and the latest revision to Regulatory Guide 1.152 which endorses IEEE 7.4.3.2-1993; a basic digital system review process was established. The NRC supplemented this review process with recently issued inspection procedures for use by NRC inspectors when conducting onsite reviews of digital modifications. In addition, the NRC undertook a major effort to codify the above guidance and the experience gained from digital system reviews of both operating plant modifications and advanced reactor designs, over these years into a revision to Standard Review Plan, (SRP), NUREG-0800, Chapter 7, Instrumentation and Control. This SRP revision was published in June, 1997, and included new SRP sections, branch technical positions and six new regulatory guides endorsing IEEE standards on software quality. The NRC staff believes that a stable digital system review process is now in place. (author)

  5. Choosing a Digital Asset Management System That's Right for You

    Science.gov (United States)

    Kaplan, Deborah

    2009-01-01

    Planning is necessary in selecting the appropriate digital asset management system for your institution. Key issues one should consider in planning: the objects to be stored, where they come from, and how they will be accessed; the end users; and the needed staffing levels for system maintenance. During the development of the system requirements,…

  6. XML: How It Will Be Applied to Digital Library Systems.

    Science.gov (United States)

    Kim, Hyun-Hee; Choi, Chang-Seok

    2000-01-01

    Shows how XML is applied to digital library systems. Compares major features of XML with those of HTML and describes an experimental XML-based metadata retrieval system, which is based on the Dublin Core and is designed as a subsystem of the Korean Virtual Library and Information System (VINIS). (Author/LRW)

  7. Improvement of digital data acquisition system in reflood test rig

    International Nuclear Information System (INIS)

    Sudoh, Takashi; Murao, Yoshio; Niitsuma, Yasushi

    1979-03-01

    The original master digital data acquisition system was designed to collect 30 channels of analog data rapidly and convert them into digital form for recording on a magnetic tape. Due to the increases in the number of channels and the ranges of measurement, an additional acquisition device was needed for the original system. This report descrives the design of the additional data acquisition device and the results of performance tests. The operational manual is attached as an appendix. It was confirmed that the new system satisfied the requirements of system. (author)

  8. Common Cause Failure Analysis for the Digital Plant Protection System

    International Nuclear Information System (INIS)

    Kagn, Hyun Gook; Jang, Seung Cheol

    2005-01-01

    Safety-critical systems such as nuclear power plants adopt the multiple-redundancy design in order to reduce the risk from the single component failure. The digitalized safety-signal generation system is also designed based on the multiple-redundancy strategy which consists of more redundant components. The level of the redundant design of digital systems is usually higher than those of conventional mechanical systems. This higher redundancy would clearly reduce the risk from the single failure of components, but raise the importance of the common cause failure (CCF) analysis. This research aims to develop the practical and realistic method for modeling the CCF in digital safety-critical systems. We propose a simple and practical framework for assessing the CCF probability of digital equipment. Higher level of redundancy causes the difficulty of CCF analysis because it results in impractically large number of CCF events in the fault tree model when we use conventional CCF modeling methods. We apply the simplified alpha-factor (SAF) method to the digital system CCF analysis. The precedent study has shown that SAF method is quite realistic but simple when we consider carefully system success criteria. The first step for using the SAF method is the analysis of target system for determining the function failure cases. That is, the success criteria of the system could be derived from the target system's function and configuration. Based on this analysis, we can calculate the probability of single CCF event which represents the CCF events resulting in the system failure. In addition to the application of SAF method, in order to accommodate the other characteristics of digital technology, we develop a simple concept and several equations for practical use

  9. Diagnostic radiology: I

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    This chapter describes the historic development of diagnostic equipment for radiology. The problems associated with fluoroscope design are detailed and the current uses of updated technology, particularly digitization, are considered. Numerous historical photographs are included. 13 refs

  10. Design type testing for digital instrumentation and control systems

    International Nuclear Information System (INIS)

    Bastl, W.; Mohns, G.

    1997-01-01

    The design type qualification of digital safety instrumentation and control is outlined. Experience shows that the concepts discussed, derived from codes, guidelines and standards, achieve useful results. It has likewise become clear that the systematics of design type qualification of the hardware components is also applicable to the software components. Design type qualification of the software, a premiere, could be performed unexpectedly smoothly. The hardware design type qualification proved that the hardware as a substrate of functionality and reliability is an issue that demands full attention, as compared to conventional systems. Another insight is that design qualification of digital instrumentation and control systems must include plant-independent systems tests. Digital instrumentation and control systems simply work very differently from conventional control systems, so that this testing modality is inevitable. (Orig./CB) [de

  11. Quality management systems in radiology. Implementation in hospital and radiology practice; Qualitaetsmanagementsysteme in der Radiologie. Umsetzung in der Klinik und Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Teichgraeber, U.; Bucourt, M. de [Charite Universitaetsmedizin Berlin (Germany). Inst. fuer Diagnostische und Interventionelle Radiologie

    2010-11-15

    The concept of quality and the principle of continuous quality improvement are implemented by quality management systems. Quality management systems surpass mere quality control. These systems account for patient and employee needs, the management style and the structure of an enterprise. Many of these quality management systems are used in the health care industry. Some of these systems and their form of application in radiology are introduced here. (orig.)

  12. Radiation protection of patients in diagnostic radiology: implementation of a management system optimization

    International Nuclear Information System (INIS)

    Corpas Rivera, L.; Devesa Pardo, F. J.; Gamez Jimenez, J. L.; Vallejo Carrascal, C.; Garcia de Diego, A. A.; Amador Vela-Hidalgo, J. J.

    2011-01-01

    The enforcement of quality in diagnostic radiology (Royal Decree 1976/1999 laying down the criteria for quality in diagnostic radiology and Royal Decree 815/2001 to justify the use of ionizing radiations for medical exposure, etc.) and recommendations and European regulations on the matter, is done by carrying out the optimization of the doses received, based on image quality in a continuous process of monitoring of such dose from the dose reference Values ??(VRD ) that the system has allowed to establish for each technique.

  13. Diagnostic radiology of the osteo-articular system. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Bohndorf, Klaus; Woertler, Klaus; Imhof, Herwig

    2014-01-01

    The book on diagnostic radiology of the osteo-articular system includes the following chapters: (1) Acute trauma and chronic overstress: essentials; (2) Acute trauma and chronic overstress (according regions); (3) Infections of bones, bone joints and soft tissue; (4) Tumors and tumor-like lesions of bones, bone joints and soft tissue; (5) Bone marrow; (6) Skeleton necrosis; (7) Osteochondrosis; (8) Metabolic, hormone related and toxically induced osteopathy; (9) Constitutional skeleton and bone joint development disturbances; (1) Rheumatic diseases; (11) Different skeletal, bone joint and soft tissue diseases; (12) Interventional actions at the skeleton, soft tissue and bone joints; (13) Radiological imaging of skeleton and bone joints.

  14. Code of practice and design principles for portable and transportable radiological protection systems

    International Nuclear Information System (INIS)

    Wells, F.H.; Powell, R.G.

    1980-10-01

    The Code of Practice and design principles for portable and transportable radiological protection systems are presented in three parts. Part 1 specifies the requirement for Radiological Protection Instrumentation (RPI) including operational characteristics and the effects of both a radiation and non-radiation environment. Part 2 satisfies the requirement for RPI equipment as regards the overall design, the availability, the reliability, the information display, the human factors, the power supplies, the manufacture and quality assurance, the testing and the cost. Part 3 deals with the supply, location and operation of the RPI equipment. (U.K.)

  15. A mobile computer system to support first responders to a radiological emergency

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Antonio J.D. da, E-mail: antoniojoseds@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Pos-Graduacao em Informatica; Santos, Joao R. dos; Pereira, Claudio M.N.A.; Carvalho, Paulo V.R., E-mail: paulov@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    Decision-making in emergency situations is characterized by its speed, pressure, and especially the uncertainty of information. Uninformed decisions or decisions based on unreliable data may lead to inappropriate actions. Although several studies that aim to combine different databases and provide full information to emergency response operation commanders can be found, only few of them are dedicated to radiological emergencies situations and even less are those that aim to provide support for the emergency first responder. We developed a system to support first responders to deal with radiological emergencies using cognitive task analysis techniques to elicit the tacitly knowledge of practitioners to grasp what information is really needed during radiological emergency response. (author)

  16. Radiological functional analysis of the vascular system contrast media, methods, results

    CERN Document Server

    1983-01-01

    Scientists and engineers have been involved in medical radiology from the very beginning. At times advances in this field occur at a tremen­ dously fast pace. Developments in radiological diagnostics have - technologically and medically speaking - focused on morphology. At present, computer-aided tomography (CAT) is at a high point in deve1opment, medical application, and validation. The preconditions for this success were rapid advances in electronics and computer technology - in hardware and in software - and an unexpected cost reduction in these fields; the co operation of various scientific disci­ plines was also essential. Functional radiological diagnosis has been neglected in part, owing to the emphasis on morphology, but alone the synthesis of morphology and function prornises further advances. Apart from the limited capabilities ofuItrasonic techniques there is no way other than using X-rays to carry out functional studies of organs and their systems through an intact body surface. It is frequently...

  17. A mobile computer system to support first responders to a radiological emergency

    International Nuclear Information System (INIS)

    Silva, Antonio J.D. da

    2013-01-01

    Decision-making in emergency situations is characterized by its speed, pressure, and especially the uncertainty of information. Uninformed decisions or decisions based on unreliable data may lead to inappropriate actions. Although several studies that aim to combine different databases and provide full information to emergency response operation commanders can be found, only few of them are dedicated to radiological emergencies situations and even less are those that aim to provide support for the emergency first responder. We developed a system to support first responders to deal with radiological emergencies using cognitive task analysis techniques to elicit the tacitly knowledge of practitioners to grasp what information is really needed during radiological emergency response. (author)

  18. Digital Microfluidic System with Vertical Functionality

    Directory of Open Access Journals (Sweden)

    Brian F. Bender

    2015-11-01

    Full Text Available Digital (droplet microfluidics (DµF is a powerful platform for automated lab-on-a-chip procedures, ranging from quantitative bioassays such as RT-qPCR to complete mammalian cell culturing. The simple MEMS processing protocols typically employed to fabricate DµF devices limit their functionality to two dimensions, and hence constrain the applications for which these devices can be used. This paper describes the integration of vertical functionality into a DµF platform by stacking two planar digital microfluidic devices, altering the electrode fabrication process, and incorporating channels for reversibly translating droplets between layers. Vertical droplet movement was modeled to advance the device design, and three applications that were previously unachievable using a conventional format are demonstrated: (1 solutions of calcium dichloride and sodium alginate were vertically mixed to produce a hydrogel with a radially symmetric gradient in crosslink density; (2 a calcium alginate hydrogel was formed within the through-well to create a particle sieve for filtering suspensions passed from one layer to the next; and (3 a cell spheroid formed using an on-chip hanging-drop was retrieved for use in downstream processing. The general capability of vertically delivering droplets between multiple stacked levels represents a processing innovation that increases DµF functionality and has many potential applications.

  19. Safety aspect of digital reactor protection system in Japan

    International Nuclear Information System (INIS)

    Ogiso, Zen-Ichi

    1998-01-01

    It was early in 1980's that the digital controllers were first applied to nuclear power plant in japan. After that, their application area had been expanding gradually, reaching to the overall integrated digital system including the safety system in Kashiwazaki-Kariwa units 6 and 7. The software for computer-based systems has been produced using the graphical language ''POL'' in Japanese nuclear power plants. It is the fundamental principle that the reliability of the software should be assured through the properly managed quality assurance. The POL-based system is fitted to this principle. In applying POL-based systems to safety system, the MITI, Ministry of International Trade and Industry, identified the licensing issues as the regulatory body, while the utilities had developed the digital technology feasible to the safety application. Through the activities, a specific industrial design guide for the software important to safety was established and the adequacy of the technology was certified through the demonstration tests of the integrated system. In the safety examination of the digital reactor protection system of K-6/7, the application of POL were approved. The POL-based systems in nuclear power plants were successful design and production process of the POL-based systems. This paper describes the activities in licensing and maintaining the computer-based systems by the utilities and manufacturers as well as the MITI. (author)

  20. Computerized method for X-ray angular distribution simulation in radiological systems

    International Nuclear Information System (INIS)

    Marques, Marcio A.; Oliveira, Henrique J.Q. de; Frere, Annie F.; Schiabel, Homero; Marques, Paulo M.A.

    1996-01-01

    A method to simulate the changes in X-ray angular distribution (the Heel effect) for radiologic imaging systems is presented. This simulation method is described as to predict images for any exposure technique considering that the distribution is the cause of the intensity variation along the radiation field