Sample records for digital radiography detectors

  1. Digital Detectors: Computed Radiography (CR for All Radiologists

    Directory of Open Access Journals (Sweden)

    Frans Dhaenens

    2007-08-01

    Full Text Available Introduction: Digital techniques in radiology have many advantages for radiologists, radiographers, patients, clinicians and hospital-operators from many perspectives: diagnostic quality, dose reduction, access to old and new images and reports via PACS, HIS and RIS."nRadiologists concentrate more and more on organs and pathology (super specialties rather than in modalities. Organ based radiology requires the integration of all modalities and has to cover large geographical regions to deliver expertise, as there few top-experts. This is only possible in the digital world of HICT (Health Information and Communication Technology, where digital detectors are the first step in a long chain of informatics."nToday most of the diagnostic imaging modalities (CT, MRI, US, PET,.. used in radiology are digital except plain film imaging. In order to digitize plain x-ray (also called General Radiology there is choice between Computed Radiography (CR based upon storage phosphor screens and DR (Digital Radiography based on "flat or panel" detectors. A large spectrum of applications and price ranges is available on the market."nTechnology: Both CR and DR rely on conversion and storage of x-ray energy in "pixel"-like elements in the detector. These detectors are linear (film is S-curved and have a enormous dynamic range (1 in 100.000 so no information is lost and they resist over- and under-exposure up to 4 times."n- In CR x-ray energy is stored into the phosphor-crystals and converted into visible light after stimulation by (laser light which is in turn captured and digitized by an optical system. Pixels (in size between 50 and 150 µm are one after one stimulated and translated into a digital image of millions of points. "n- In DR systems x-ray energy is converted in 2 or 3 steps into electrical charge that is stored in every pixel of the detector. These charges are digitized row after row to make a digital image. The conversion of the x-rays is done by a

  2. Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore Pipelines

    Directory of Open Access Journals (Sweden)

    Lopes RicardoTadeu

    2010-01-01

    Full Text Available Digital radiography in the inspection of welded pipes to be installed under deep water offshore gas and oil pipelines, like a presalt in Brazil, in the paper has been investigated. The aim is to use digital radiography for nondestructive testing of welds as it is already in use in the medical, aerospace, security, automotive, and petrochemical sectors. Among the current options, the DDA (Digital Detector Array is considered as one of the best solutions to replace industrial films, as well as to increase the sensitivity to reduce the inspection cycle time. This paper shows the results of this new technique, comparing it to radiography with industrial films systems. In this paper, 20 test specimens of longitudinal welded pipe joints, specially prepared with artificial defects like cracks, lack of fusion, lack of penetration, and porosities and slag inclusions with varying dimensions and in 06 different base metal wall thicknesses, were tested and a comparison of the techniques was made. These experiments verified the purposed rules for parameter definitions and selections to control the required digital radiographic image quality as described in the draft international standard ISO/DIS 10893-7. This draft is first standard establishing the parameters for digital radiography on weld seam of welded steel pipes for pressure purposes to be used on gas and oil pipelines.

  3. Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristics.

    Science.gov (United States)

    Cowen, A R; Kengyelics, S M; Davies, A G

    2008-05-01

    Solid-state, digital radiography (DR) detectors, designed specifically for standard projection radiography, emerged just before the turn of the millennium. This new generation of digital image detector comprises a thin layer of x-ray absorptive material combined with an electronic active matrix array fabricated in a thin film of hydrogenated amorphous silicon (a-Si:H). DR detectors can offer both efficient (low-dose) x-ray image acquisition plus on-line readout of the latent image as electronic data. To date, solid-state, flat-panel, DR detectors have come in two principal designs, the indirect-conversion (x-ray scintillator-based) and the direct-conversion (x-ray photoconductor-based) types. This review describes the underlying principles and enabling technologies exploited by these designs of detector, and evaluates their physical imaging characteristics, comparing performance both against each other and computed radiography (CR). In standard projection radiography indirect conversion DR detectors currently offer superior physical image quality and dose efficiency compared with direct conversion DR and modern point-scan CR. These conclusions have been confirmed in the findings of clinical evaluations of DR detectors. Future trends in solid-state DR detector technologies are also briefly considered. Salient innovations include WiFi-enabled, portable DR detectors, improvements in x-ray absorber layers and developments in alternative electronic media to a-Si:H.

  4. COMPARISON OF WIRELESS DETECTORS FOR DIGITAL RADIOGRAPHY SYSTEMS: IMAGE QUALITY AND DOSE.

    Science.gov (United States)

    Mourik, J E M; van der Tol, P; Veldkamp, W J H; Geleijns, J

    2016-06-01

    The purpose of this study was to compare dose and image quality of wireless detectors for digital chest radiography. Entrance dose at both the detector (EDD) and phantom (EPD) and image quality were measured for wireless detectors of seven different vendors. Both the local clinical protocols and a reference protocol were evaluated. In addition, effective dose was calculated. Main differences in clinical protocols involved tube voltage, tube current, the use of a small or large focus and the use of additional filtration. For the clinical protocols, large differences in EDD (1.4-11.8 µGy), EPD (13.9-80.2 µGy) and image quality (IQFinv: 1.4-4.1) were observed. Effective dose was systems. Although effective dose is low, further improvement of imaging technology and acquisition protocols is warranted for optimisation of digital chest radiography.

  5. Photon-counting digital radiography using high-pressure xenon filled detectors

    CERN Document Server

    Li, Maozhen; Johns, P C

    2001-01-01

    Digital radiography overcomes many of the limitations of the traditional screen/film system. Further enhancements in the digital radiography image are possible if the X-ray image receptor could measure the energy of individual photons instead of simply integrating their energy, as is the case at present. A prototype photon counting scanned projection radiography system has been constructed, which combines a Gas Electron Multiplier (GEM) and a Gas Microstrip Detector (GMD) using Xe : CH sub 4 (90 : 10) at high pressure. With the gain contribution from the GEM, the GMD can be operated at lower and safer voltages making the imaging system more reliable. Good energy resolution, and spatial resolution comparable to that of screen/film, have been demonstrated for the GEM/GMD hybrid imaging system in photon counting mode for X-ray spectra up to 50 kV.

  6. Digital Radiography and Computed Tomography Project -- Fully Integrated Linear Detector ArrayStatus Report

    Energy Technology Data Exchange (ETDEWEB)

    Tim Roney; Robert Seifert; Bob Pink; Mike Smith

    2011-09-01

    The field-portable Digital Radiography and Computed Tomography (DRCT) x-ray inspection systems developed for the Project Manager for NonStockpile Chemical Materiel (PMNSCM) over the past 13 years have used linear diode detector arrays from two manufacturers; Thomson and Thales. These two manufacturers no longer produce this type of detector. In the interest of insuring the long term viability of the portable DRCT single munitions inspection systems and to improve the imaging capabilities, this project has been investigating improved, commercially available detectors. During FY-10, detectors were evaluated and one in particular, manufactured by Detection Technologies (DT), Inc, was acquired for possible integration into the DRCT systems. The remainder of this report describes the work performed in FY-11 to complete evaluations and fully integrate the detector onto a representative DRCT platform.

  7. CCD digital radiography system

    Science.gov (United States)

    Wang, Yi; Kang, Xi; Li, Yuanjing; Cheng, Jianping; Hou, Yafei; Han, Haiwei

    2009-07-01

    Amorphous silicon flat-panel detector is the mainstream used in digital radiography (DR) system. In latest years, scintillation screen coupled with CCD DR is becoming more popular in hospital. Compared with traditional amorphous silicon DR, CCD-DR has better spatial resolution and has little radiation damage. It is inexpensive and can be operated easily. In this paper, A kind of CCD based DR system is developed. We describe the construction of the system, the system performances and experiment results.

  8. Recent developments in a CdTe-based x-ray detector for digital radiography

    Science.gov (United States)

    Glasser, Francis; Martin, Jean-Luc; Thevenin, Bernard; Schermesser, Patrick; Pantigny, Philippe; Laurent, Jean Yves; Rambaud, Philippe; Pitault, Bernard; Paltrier, Sylvain

    1997-05-01

    The performance of a new CdTe based x-ray detector devoted to digital radiography are presented. The detectors consist of a 6 cm2 CdTe 2D-array connected to CMOS readout circuit by indium bumps. The final image has 400 X 600 pixels with a 50 micron pitch. This solid-state detector presents the advantages of direct conversion, i.e. high stopping power with high spatial resolution and a significantly higher signal than commercially available scintillator/photodetector systems. The experimental results show excellent linearity, spatial resolution and detective quantum efficiency. The MTF was measured by the angled-slit method: 20 to 30 percent at 10 1p/mm depending on the incident x-ray energy. The measured DQE is about 0.8 at 40 KeV and 100 (mu) Gray dose. Our simulation shows that these experimental results do not reach the theoretical limit. Further improvements are in progress. The first industrial application will be dental radiography due to the small size and the excellent performances. We also tested the detector with x-rays form 20 KeV to 1.25 MeV. Of course the CdTe thickness should then be adapted to the incident x-ray energy.

  9. Digital radiography

    DEFF Research Database (Denmark)

    Precht, H; Gerke, O; Rosendahl, K

    2012-01-01

    BACKGROUND: New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults...

  10. Image quality of a digital chest radiography system based on a selenium detector.

    Science.gov (United States)

    Neitzel, U; Maack, I; Günther-Kohfahl, S

    1994-04-01

    A digital chest radiography system has been developed, with a detector based on the photoelectric properties of amorphous selenium. The selenium layer is deposited on a cylindrical aluminium drum, large enough to cover the full field of view for chest imaging. The electrostatic charge image which is formed on the selenium surface after x-ray exposure is read out by electrometer probes using fast drum rotation. For a physical evaluation of the attainable image quality, the characteristic curve, the modulation transfer function, and the noise spectra were measured. From these measurements, the signal-to-noise properties of the detector in terms of detective quantum efficiency (DQE) and noise equivalent quanta (NEQ) were derived. The results show that the selenium-based detector has a wide dynamic range and a significantly better DQE than screen-film and storage phosphor systems for spatial frequencies below the Nyquist limit (2.7 lp/mm). As a consequence, the detectability of small, low-contrast details is considerably improved.

  11. MTF compensation for digital radiography system with indirect conversion flat panel detector

    Science.gov (United States)

    Zhang, Wei; Souchay, Henri; Yang, Chao

    2009-02-01

    The MTF (modulation transfer function) of digital radiography systems can be enhanced in the spatial frequency domain due to their high signal to noise ratio. A Wiener filter, which requires prior estimation of the noise and signal power spectrum of the images, was used to compensate MTF of the detector and thereby optimally restore the images details. We studied the noise characteristics of two flat panel detectors with structured columnar scintillator (CsI) and granular scintillator (Gd2O2S). A noise model formulating noise transfer process was applied to estimate the noise components for the filter. Signal model was based on dose of the application. We revisited the noise and signal model that was used in previous work by Souchay et al. for mammography application [1], considering the difference in detector characteristics and the applications (extremity x-ray) that we are specifically investigating. Starting with real clinical images, we used an observer study method to measure the visually optimal parameter for the Wiener filter. A set of clinical images was used to evaluate the radiologists' preferences to compensated images against the reference images. Statistical results from three experienced radiologists ranking results show that the compensated images are preferred over the reference images.

  12. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Vejle-Sørensen, Jens Kristian; Thomsen, Henrik;

    2015-01-01

    of clinical supervisors. Optimal collimation is determined by European and Regional Danish guidelines. The areal between current and optimal collimation is calculated. The experimental research is performed in September - October 2014 Siemens Axiom Aristos digital radiography system DR using 150 kV, 1,25 -3......Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... one hundred fifty self-reliant female patients between 15 and 55 years of age are included in the study. The clinical research is performed between September and November 2014 where 3rd year Radiography students collect data on four Danish x-ray departments using identical procedures under guidance...

  13. Digital chest radiography

    DEFF Research Database (Denmark)

    Debess, Jeanne Elisabeth; Johnsen, Karen Kirstine; Thomsen, Henrik

    2015-01-01

    Background: Chest radiography is one of the most common examinations in radiology departments. In 2013 approximately 80,000 chest x-rays were performed on women in the fertile age. Even low dose for the examinationCorrect collimation Purpose: Quality improvement of basic radiography focusing...... collimations depending on side of radiograph. Results from dose reduction will be presented on the congress Conclusion: Correct positioning and collimation of digital chest radiographs can reduce the radiation dose significant to the patients and by that improve the quality of basic radiography....... on collimation and dose reduction in digital chest radiography Methods and Materials A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from one hundred fifty self-reliant female patients between 15 and 55 years...

  14. NPWE model observer as a validated alternative for contrast detail analysis of digital detectors in general radiography

    Science.gov (United States)

    Van Peteghem, N.; Bosmans, H.; Marshall, N. W.

    2016-11-01

    To propose and validate a non-prewhitening with eye filter (NPWE) model observer as an alternative means of quantifying and specifying imaging performance for general radiography detectors, in a comparative study with contrast detail analysis and detective quantum efficiency (DQE). Five different x-ray detectors were assessed, covering a range of detector technologies including powder computed radiography (CR), needle CR, and three indirect conversion flat panel digital radiography detectors (DR). For each detector, threshold contrast detail (c-d) detectability was measured using the Leeds TO20 test object. A tube voltage of 70 kV and 1 mm Cu added filtration was used and five target detector air kerma (DAK) levels were set, ranging from 0.625 µGy to 10 µGy. Three c-d images were acquired at the same DAK levels and these were scored by two observers. Presampling modulation transfer function (MTF) was measured using an edge method while contrast was measured with a 2 mm Al square of dimension 10  ×  10 mm. The normalized noise power spectrum (NNPS) was calculated at the target DAK values of the c-d images. The MTF, NNPS and contrast data were then used to calculate a detectability index (d‧) with the NPWE model and compared to the human observer c-d results. The standard quantitative means of evaluating detector performance i.e. DQE, was then calculated for each detector. A linear correlation was found between the logarithm of threshold contrast and the logarithm of d’ for all detectors, as DAK was increased. Furthermore, the absolute value of d‧ tracked threshold contrast between the five detectors, enabling the use of detectability to quantify image quality rather than the intrinsically subjective threshold contrast scored by human observers from c-d test object images. At 2.5 µGy target DAK, d’ followed the differences in DQE between the five detectors. The NPWE detectability index can be used an alternative parameter for the

  15. Artifacts in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Min, Jung Whan [Dept. of Radiological Technology, Shin Gu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Technology, Korea University, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, Beakseok Culture University, Cheonan (Korea, Republic of)

    2015-12-15

    Digital Radiography is a big part of diagnostic radiology. Because uncorrected digital radiography image supported false effect of Patient’s health care. We must be manage the correct digital radiography image. Thus, the artifact images can have effect to make a wrong diagnosis. We report types of occurrence by analyzing the artifacts that occurs in digital radiography system. We had collected the artifacts occurred in digital radiography system of general hospital from 2007 to 2014. The collected data had analyzed and then had categorize as the occurred causes. The artifacts could be categorized by hardware artifacts, software artifacts, operating errors, system artifacts, and others. Hardware artifact from a Ghost artifact that is caused by lag effect occurred most frequently. The others cases are the artifacts caused by RF noise and foreign body in equipments. Software artifacts are many different types of reasons. The uncorrected processing artifacts and the image processing error artifacts occurred most frequently. Exposure data recognize (EDR) error artifacts, the processing error of commissural line, and etc., the software artifacts were caused by various reasons. Operating artifacts were caused when the user did not have the full understanding of the digital medical image system. System artifacts had appeared the error due to DICOM header information and the compression algorithm. The obvious artifacts should be re-examined, and it could result in increasing the exposure dose of the patient. The unclear artifact leads to a wrong diagnosis and added examination. The ability to correctly determine artifact are required. We have to reduce the artifact occurrences by understanding its characteristic and providing sustainable education as well as the maintenance of the equipments.

  16. Data pre-processing for quantification in tomography and radiography with a digital flat panel detector

    Science.gov (United States)

    Rinkel, Jean; Gerfault, Laurent; Estève, François; Dinten, Jean-Marc

    2006-03-01

    In order to obtain accurate quantitative results, flat panel detectors require specific calibration and correction of acquisitions. Main artefacts are due to bad pixels, variations of photodiodes characteristics and inhomogeneity of X-rays sensitivity of the scintillator layer. Other limitations for quantification are the non-linearity of the detector due to charge trapping in the transistors and the scattering generated inside the detector, called detector scattering. Based on physical models of artefacts generation, this paper presents an unified framework for the calibration and correction of these artefacts. The following specific algorithms have been developed to correct them. A new method for correction of deviation to linearity is based on the comparison between experimental and simulated data. A method of detector scattering correction is performed in two steps: off-line characterization of detector scattering by considering its spatial distribution through a convolution model and on-line correction based on a deconvolution approach. Radiographic results on an anthropomorphic thorax phantom imaged with a flat panel detector, that convert X-rays into visible light using scintillator coupled to an amorphous silicon transistor frame for photons to electrons conversion, demonstrate that experimental X-rays attenuation images are significantly improved qualitatively and quantitatively by applying non-linearity correction and detector scattering correction. Results obtained on tomographic reconstructions from pre-processed acquisitions of the phantom are in very good agreement with expected attenuation coefficients values obtained with a multi-slice CT scanner. Thus, this paper demonstrates the efficiency of the proposed pre-processings to perform accurate quantification on radiographies and tomographies.

  17. Optimizing the tube potential for lumbar spine radiography with a flat-panel digital detector.

    Science.gov (United States)

    Geijer, H; Norrman, E; Persliden, J

    2009-01-01

    The purpose of this study was to find the optimal settings for lumbar spine radiography with a flat-panel detector. A CDRAD contrast-detail phantom was imaged at various tube potentials, system speeds and filtration settings. Factorial experiments yielded a range of optimized exposure settings, which were submitted to visual grading analysis with images of an Alderson phantom. The first optimized settings involved a system speed increase from 400 to 800. For anteroposterior projection, the optimal tube potential was reduced from the default of 77 kV to 60 kV to give the best image quality without increasing the effective dose, or to 66 kV to give the lowest dose without reducing image quality. For lateral projection, the tube potential was similarly reduced from the default of 90 kV to 70 kV or 77 kV. Visual grading analysis confirmed the results, with significantly better image quality when optimizing for image quality. The study thus shows that the tube potential can be reduced as long as the system speed is increased simultaneously. This leads to a lower effective dose and/or increased image quality depending on the settings chosen. The factorial experiments provided a powerful way to evaluate several parameters concomitantly.

  18. Development of CT and 3D-CT Using Flat Panel Detector Based Real-Time Digital Radiography System

    Science.gov (United States)

    Ravindran, V. R.; Sreelakshmi, C.; Vibin, Vibin

    2008-09-01

    The application of Digital Radiography in the Nondestructive Evaluation (NDE) of space vehicle components is a recent development in India. A Real-time DR system based on amorphous silicon Flat Panel Detector has been developed for the NDE of solid rocket motors at Rocket Propellant Plant of VSSC in a few years back. The technique has been successfully established for the nondestructive evaluation of solid rocket motors. The DR images recorded for a few solid rocket specimens are presented in the paper. The Real-time DR system is capable of generating sufficient digital X-ray image data with object rotation for the CT image reconstruction. In this paper the indigenous development of CT imaging based on the Realtime DR system for solid rocket motor is presented. Studies are also carried out to generate 3D-CT image from a set of adjacent CT images of the rocket motor. The capability of revealing the spatial location and characterisation of defect is demonstrated by the CT and 3D-CT images generated.

  19. Assessment of image quality in orthopaedic radiography with digital detectors: a visual grading analysis

    Science.gov (United States)

    Decoster, Robin; Mol, Harrie; van den Broeck, Renaat; Smits, Dirk

    2013-03-01

    Background: The introduction of digital detectors in the radiology predicted a dose reduction. Due to the dynamic range, radiographs of sufficient quality can be produced with a lower detector air kerma (DAK). However, this reduction was not observed. Some authors indicate a creep towards higher DAK, explained by a better appreciation of the radiographs due to a higher contrast-to-noise ratio. Methodology: To investigate the relation between the DAK and the appreciation of image quality by radiologists, 172 anterior-posterior (AP) radiographs of the knee and 152 radiographs of the pelvis were collected in 19 radiology centres. A Visual Grading Analysis (VGA) with a five-point scale was used to judge the image quality of seven different anatomic structures. The mid-point of the scale (3) was equalized to diagnostic image quality. Six experienced radiologists scored both datasets, in a controlled environment, with ViewDex®. Every observer received instructions and a training dataset. Moreover, twenty radiographs were repeated to determine intra-observer variability. Results: The intra-observer variability was not significant (p>0.05) for both datasets. The knee AP obtained a VGAS score of 3.91, the pelvis AP obtained a VGAS score of 3.71. In both cases, the inter-observer correlation was high and significant. The correlation between the VGAS and the DAK (0.41μGy - 6.18μGy) was not significant in either of the cases; neither did other analysises based on technical parameters. Conclusion: The VGA revealed an image quality higher than diagnostic necessary. Based on the DAK, an overexposure is suspected. The relation between DAK and the appreciation has to be further investigated in detail.

  20. Digital radiography: image quality and radiation dose.

    Science.gov (United States)

    Seibert, J Anthony

    2008-11-01

    Digital radiography devices, rapidly replacing analog screen-film detectors, are now common in diagnostic radiological imaging, where implementation has been accelerated by the commodity status of electronic imaging and display systems. The shift from narrow latitude, fixed-speed screen-film detectors to wide latitude, variable-speed digital detectors has created a flexible imaging system that can easily result in overexposures to the patient without the knowledge of the operator, thus potentially increasing the radiation burden of the patient population from radiographic examinations. In addition, image processing can be inappropriately applied causing inconsistent or artifactual appearance of anatomy, which can lead to misdiagnosis. On the other hand, many advantages can be obtained from the variable-speed digital detector, such as an ability to lower dose in many examinations, image post-processing for disease-specific conditions, display flexibility to change the appearance of the image and aid the physician in making a differential diagnosis, and easy access to digital images. An understanding of digital radiography is necessary to minimize the possibility of overexposures and inconsistent results, and to achieve the principle of as low as reasonably achievable (ALARA) for the safe and effective care of all patients. Thus many issues must be considered for optimal implementation of digital radiography, as reviewed in this article.

  1. Simulation of computed radiography with imaging plate detectors

    Energy Technology Data Exchange (ETDEWEB)

    Tisseur, D.; Costin, M. [CEA LIST, CEA Saclay 91191 Gif sur Yvette Cedex (France); Mathy, F. [CEA-LETI, Campus Minatec, F-38054, Grenoble (France); Schumm, A. [EDF R and D, 1 avenue du général de gaulle 92141 Clamart (France)

    2014-02-18

    Computed radiography (CR) using phosphor imaging plate detectors is taking an increasing place in Radiography Testing. CR uses similar equipment as conventional radiography except that the classical X-ray film is replaced by a numerical detector, called image plate (IP), which is made of a photostimulable layer and which is read by a scanning device through photostimulated luminescence. Such digital radiography has already demonstrated important benefits in terms of exposure time, decrease of source energies and thus reduction of radioprotection area besides being a solution without effluents. This paper presents a model for the simulation of radiography with image plate detectors in CIVA together with examples of validation of the model. The study consists in a cross comparison between experimental and simulation results obtained on a step wedge with a classical X-ray tube. Results are proposed in particular with wire Image quality Indicator (IQI) and duplex IQI.

  2. Exploration of exposure conditions with a novel wireless detector for bedside digital radiography

    Science.gov (United States)

    Bosmans, Hilde; Nens, Joris; Delzenne, Louis; Marshall, Nicholas; Pauwels, Herman; De Wever, Walter; Oyen, Raymond

    2012-03-01

    We propose, apply and validate an optimization scheme for a new wireless CsI based DR detector in combination with a regular mobile X-ray system for bedside imaging applications. Three different grids were tested in this combination. Signal-difference-to-noise was investigated in two ways, using a 1mm Cu piece in combination with different thicknesses of PMMA and by means of the CDRAD phantom using 10 images per condition and an automated evaluation method. A Figure of Merit (FOM), namely SDNR2/Imparted Energy, was calculated for a large range of exposure conditions, without and with grid in place. Misalignment of the grids was evaluated via the same FOMs. This optimization study was validated with comparative X-ray acquisitions performed on dead bodies. An experienced radiologist scored the quality of several specific aspects for all these exposures. Signal difference to noise ratios measured with the Cu method correlated well with the threshold contrasts from the CDRAD analysis (R2 > 0.9). The analysis showed optimal FOM with detector air kerma rates as typically used in clinical practice. Lower tube voltages provide higher FOM than the higher values but their practical use depends on the limitations of X-ray tubes, linked to patient motion artefacts. The use of high resolution grids should be encouraged, as the FOM increases with 47% at 75kV. These scores from the Visual grading study confirmed the results obtained with the FOM. The switch to (wireless) DR technology for bedside imaging could benefit from devices to improve grid positioning or any scatter reduction technique.

  3. [Comparative radiography of the respiratory tract of snakes using conventional high-resolution film-screen-system and a digital detector system].

    Science.gov (United States)

    Pees, Michael; Bochmann, Monika; Krautwald-Junghanns, Maria-Elisabeth; Schmidt, Volker; Ludewig, Eberhard

    2010-01-01

    A conventional high-resolution screen-film-system (film Kodak MIN-R S, screen Kodak MIN-R 2000) was compared to a digital detector system (Varian PaxScan 4030E) for the evaluation of the respiratory tract in snakes. Digital radiographs were taken with the same dose as well as with half the dose used for the conventional radiographs. A total of 20 Burmese pythons (Python molurus) were examined in dorsoventral and lateral projection. Four criteria (three features, one overall assessment) were defined for each of the anatomical structures lung, trachea and spinal column and assessed by five veterinarians in a semi-blinded study using a score system. Comparison of the ratings between the techniques used was done using a visual grading analysis. For the lung, two of the three features as well as the overall assessment were rated significantly superior using the digital system. The trachea was rated significantly superior using the conventional system for the overall assessment as well as for one feature. For the spinal column, the overall assessment was significantly superior using the digital system with the full dose. Conventional radiography as well as digital radiography using half the dose was rated significantly inferior for one feature each. The of the relatively low-contrast respiratory tract. A limiting factor is the demonstration of particularly small structures. Generally, a dose reduction (compared to a conventional high-resolution film-screen-system) is possible for the evaluation of the respiratory system.

  4. Evaluation of cassette-based digital radiography detectors using standardized image quality metrics: AAPM TG-150 Draft Image Detector Tests.

    Science.gov (United States)

    Li, Guang; Greene, Travis C; Nishino, Thomas K; Willis, Charles E

    2016-09-08

    The purpose of this study was to evaluate several of the standardized image quality metrics proposed by the American Association of Physics in Medicine (AAPM) Task Group 150. The task group suggested region-of-interest (ROI)-based techniques to measure nonuniformity, minimum signal-to-noise ratio (SNR), number of anomalous pixels, and modulation transfer function (MTF). This study evaluated the effects of ROI size and layout on the image metrics by using four different ROI sets, assessed result uncertainty by repeating measurements, and compared results with two commercially available quality control tools, namely the Carestream DIRECTVIEW Total Quality Tool (TQT) and the GE Healthcare Quality Assurance Process (QAP). Seven Carestream DRX-1C (CsI) detectors on mobile DR systems and four GE FlashPad detectors in radiographic rooms were tested. Images were analyzed using MATLAB software that had been previously validated and reported. Our values for signal and SNR nonuniformity and MTF agree with values published by other investigators. Our results show that ROI size affects nonuniformity and minimum SNR measurements, but not detection of anomalous pixels. Exposure geometry affects all tested image metrics except for the MTF. TG-150 metrics in general agree with the TQT, but agree with the QAP only for local and global signal nonuniformity. The difference in SNR nonuniformity and MTF values between the TG-150 and QAP may be explained by differences in the calculation of noise and acquisition beam quality, respectively. TG-150's SNR nonuniformity metrics are also more sensitive to detector nonuniformity compared to the QAP. Our results suggest that fixed ROI size should be used for consistency because nonuniformity metrics depend on ROI size. Ideally, detector tests should be performed at the exact calibration position. If not feasible, a baseline should be established from the mean of several repeated measurements. Our study indicates that the TG-150 tests can be

  5. Development of Portable Digital Radiography System with a Device for Monitoring X-ray Source-Detector Angle and Its Application in Chest Imaging

    Directory of Open Access Journals (Sweden)

    Tae-Hoon Kim

    2017-03-01

    Full Text Available This study developed a device measuring the X-ray source-detector angle (SDA and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR was evaluated using the signal-to-noise (SNR, contrast-to-noise ratio (CNR, spatial resolution, distortion and entrance surface dose (ESD. According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles (p < 0.05, whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines.

  6. Varied tube potential with constant effective dose at lumbar spine radiography using a flat-panel digital detector.

    Science.gov (United States)

    Geijer, Håkan; Persliden, Jan

    2005-01-01

    The purpose of the study was to evaluate the image quality at different tube potential (kV) settings using anteroposterior lumbar spine radiography as a model. An Alderson phantom was used with a flat-panel detector. The tube potential varied between 48 and 125 kV while the tube charge (mAs) was adjusted to keep an effective dose of 0.11 mSv. Image quality was assessed with a visual grading analysis and with a CDRAD contrast-detail phantom together with a computer program. The VGA showed inferior image quality for the higher kV settings, > or =96 kVwith similar results for the contrast-detail phantom. When keeping the effective dose fixed, it seems beneficial to reduce kV to get the best image quality despite the fact that the mAs is not as high as with automatic exposure. However, this cannot be done with automatic exposure, which is set for a constant detector dose.

  7. Digital chest radiography: collimation and dose reduction

    DEFF Research Database (Denmark)

    Debess, Jeanne; Johnsen, Karen Kirstine; Vejle-Sørensen, Jens Kristian

    Purpose: Quality improvement of basic radiography focusing on collimation and dose reduction in digital chest radiography Methods and Materials:A retrospective study of digital chest radiography is performed to evaluate the primary x-ray tube collimation of the PA and lateral radiographs. Data from...... of clinical supervisors. Optimal collimation is determined by European and Regional Danish guidelines. The areal between current and optimal collimation is calculated. The experimental research is performed in September - October 2014 Siemens Axiom Aristos digital radiography system DR using 150 kV, 1,25 -3...

  8. Development and evaluation of a digital radiography system using a large-area flat-panel detector

    Science.gov (United States)

    Suzuki, Katsumi; Ikeda, Shigeyuki; Ishikawa, Ken; Iinuma, Gen; Ogasawara, Satoshi; Moriyama, Noriyuki; Konno, Yasutaka

    2002-05-01

    A new DR system using a large-area flat panel detector (FPD) with a 40 by 30 cm active area and a 194 micrometers pixel pitch, has been developed to compare with a conventional image intensifier and charge-coupled device camera type DR system. After measuring basic characteristics of the new DR system such as signal-to-noise ratio, modulation transfer function, and detective quantum efficiency, we applied the FPD to a Gastro-Intestinal study with contrast media, and discussed its potential for clinical use with a medical doctor. In radiography mode, the new DR system with a large-are FPD has superior image quality compared with the conventional I.I.- CCD camera type DR system because of high SNR and DQE. In fluoroscopy mode, the SNR of the new DR system at the exposure range of over 2(mu) R/frame is similar with the conventional I.I.-CCD camera type DR system. As a result, we considered that new DR system with a large-area FPD could be applied to a clinical study replacing an I.I.-CCD camera type. In the evaluation using various clinical images taken with the new DR system by a medical doctor, the new DR system with a large-are FPD performed sufficiently for a GI study.

  9. Digital radiography exposure indices: A review

    Energy Technology Data Exchange (ETDEWEB)

    Mothiram, Ursula; Brennan, Patrick C; Lewis, Sarah J [Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of Health Science, University of Sydney, Sydney, New South Wales (Australia); Moran, Bernadette [Department of Clinical Medicine, Trinity College, Dublin (Ireland); Robinson, John [Medical Imaging Optimisation and Perception Group (MIOPeG), Discipline of Medical Radiation Sciences, Faculty of Health Science, University of Sydney, Sydney, New South Wales (Australia)

    2014-06-15

    Digital radiography (DR) technologies have the advantage of a wide dynamic range compared to their film-screen predecessors, however, this poses a potential for increased patient exposure if left unchecked. Manufacturers have developed the exposure index (EI) to counter this, which provides radiographers with feedback on the exposure reaching the detector. As these EIs were manufacturer-specific, a wide variety of EIs existed. To offset this, the international standardised EI has been developed by the International Electrotechnical Commission (IEC) and the American Association of Physicists in Medicine (AAPM). The purpose of this article is to explore the current literature relating to EIs, beginning with the historical development of the EI, the development of the standardised EI and an exploration of common themes and studies as evidenced in the research literature. It is anticipated that this review will provide radiographers with a useful guide to understanding EIs, their application in clinical practice, limitations and suggestions for further research.

  10. Radiation dose reduction in scoliosis patients. Low-dose full-spine radiography with digital flat panel detector and image stitching system

    Energy Technology Data Exchange (ETDEWEB)

    Grieser, T. [Klinikum Augsburg (Germany). Klinik fuer Diagnostische Radiologie und Neuroradiologie; Baldauf, A.Q. [Theresienkrankenhaus Mannheim (Germany). Abt. fuer Radiologie; Ludwig, K. [Klinikum Herford (Germany). Klinik fuer Diagnostische und Interventionelle Radiologie

    2011-07-15

    Purpose: To evaluate the exposure dose reduction with a digital flat panel detector (FPD) and an image stitching system (ISS) in full-spine radiography for scoliosis patients. Materials and Methods: During a 6-month period, all consecutive scoliosis patients with a clinical indication for full-spine radiography (n = 50) were examined with an FPD and ISS. Automatic exposure control adjusted to speed class 1600 was used together with age-adjusted tube voltage and filtration. Dose area products were recorded for all images (antero-posterior n = 50, lateral n = 18). Images were evaluated by two radiologists for the possibility (possible, impossible) of typical scoliosis measurements (Cobb angle, Stagnara angle, lateral deviation, Risser stage). All measurements assessed as impossible underwent a second evaluation categorizing the reason why a measurement was impossible (underlying pathology, projection, image quality). Patient characteristics influencing exposure were recorded (sex, age, weight, height). Mean dose area products were compared to the literature with consideration of patient group and image quality. Results: The mean dose area product was 16.8 {mu}Gy m{sup 2} for antero-posterior images and 26.6 {mu}Gy m{sup 2} for lateral images. A comparison to published values showed an exposure dose reduction of 47 % to 93 %. Measurement of the Cobb and Stagnara angle, lateral deviation and Risser stage was possible in 96 % (n = 50), 83 % (n = 18), 100 % (n = 50) and 100 % (n = 50) of cases. The reasons for impossible measurements were independent of image quality (underlying pathologies, projection). Conclusion: When imaging scoliosis patients, an FPD combined with an ISS can substantially reduce the exposure dose. (orig.)

  11. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  12. Portable Digital Radiography and Computed Tomography Manual

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-01

    This user manual describes the function and use of the portable digital radiography and computed tomography (DRCT) scanner. The manual gives a general overview of x-ray imaging systems along with a description of the DRCT system. An inventory of the all the system components, organized by shipping container, is also included. In addition, detailed, step-by-step procedures are provided for all of the exercises necessary for a novice user to successfully collect digital radiographs and tomographic images of an object, including instructions on system assembly and detector calibration and system alignment. There is also a short section covering the limited system care and maintenance needs. Descriptions of the included software packages, the DRCT Digital Imager used for system operation, and the DRCT Image Processing Interface used for image viewing and tomographic data reconstruction are given in the appendixes. The appendixes also include a cheat sheet for more experienced users, a listing of known system problems and how to mitigate them, and an inventory check-off sheet suitable for copying and including with the machine for shipment purposes.

  13. Digital radiography: a survey of pediatric dentists.

    Science.gov (United States)

    Russo, Julie M; Russo, James A; Guelmann, Marcio

    2006-01-01

    The purpose of this study was to: (1) determine the popularity of digital radiography among members of the American Academy of Pediatric Dentistry (AAPD); and (2) report the most common systems in use. An AAPD-approved, voluntary, and anonymous electronic survey was developed and sent to 923 board certified pediatric dentists. Years in practice and in-office x-ray technology (digital or conventional) were inquired about initially. If negative for the use of digital radiography, future consideration for converting to digital radiography was ascertained. For positive responses, more in-depth information was requested. Information on type of system (sensor or phosphor plate), user friendliness, diagnostic ability, patient's comfort, general costs, durability, and parental and overall satisfaction was collected. For most of the questions, a 5-point assessment scale was used. Opportunity for additional comments was provided upon survey completion. Data was analyzed using descriptive statistics. A 32% (296/923) response rate was obtained. Twenty-six percent of practitioners (78/296) implemented digital radiography in their practices, whereas 71% considered future acquisition. Similar distribution for sensor and phosphor plate users was found. Sensor technology was reported to produce faster images, but was less tolerable by young children due to size and thickness. Phosphor plates were considered more children friendly, less expensive, and less durable. Parental satisfaction was very high with great marketing value. Picture quality was comparable to conventional film. Overall, digital radiography users would recommend it to other pediatric dentists. Digital radiography is not yet popular among pediatric dentists. Cost reduction and technology advancement may enhance utilization.

  14. Axial Tomography from Digitized Real Time Radiography

    Science.gov (United States)

    Zolnay, A. S.; McDonald, W. M.; Doupont, P. A.; McKinney, R. L.; Lee, M. M.

    1985-01-18

    Axial tomography from digitized real time radiographs provides a useful tool for industrial radiography and tomography. The components of this system are: x-ray source, image intensifier, video camera, video line extractor and digitizer, data storage and reconstruction computers. With this system it is possible to view a two dimensional x-ray image in real time at each angle of rotation and select the tomography plane of interest by choosing which video line to digitize. The digitization of a video line requires less than a second making data acquisition relatively short. Further improvements on this system are planned and initial results are reported.

  15. Photon counting detector for the personal radiography inspection system "SIBSCAN"

    Science.gov (United States)

    Babichev, E. A.; Baru, S. E.; Grigoriev, D. N.; Leonov, V. V.; Oleynikov, V. P.; Porosev, V. V.; Savinov, G. A.

    2017-02-01

    X-ray detectors operating in the energy integrating mode are successfully used in many different applications. Nevertheless the direct photon counting detectors, having the superior parameters in comparison with the integrating ones, are rarely used yet. One of the reasons for this is the low value of the electrical signal generated by a detected photon. Silicon photomultiplier (SiPM) based scintillation counters have a high detection efficiency, high electronic gain and compact dimensions. This makes them a very attractive candidate to replace routinely used detectors in many fields. More than 10 years ago the digital scanning radiography system based on multistrip ionization chamber (MIC) was suggested at Budker Institute of Nuclear Physics. The detector demonstrates excellent radiation resistance and parameter stability after 5 year operations and an imaging of up to 1000 persons per day. Currently, the installations operate at several Russian airports and at subway stations in some cities. At the present time we design a new detector operating in the photon counting mode, having superior parameters than the gas one, based on scintillator - SiPM assemblies. This detector has close to zero noise, higher quantum efficiency and a count rate capability of more than 5 MHz per channel (20% losses), which leads to better image quality and improved detection capability. The suggested detector technology could be expanded to medical applications.

  16. Practical application of suspension criteria scenarios in general radiography, computed radiography,digital radiography and fluoroscopy.

    Science.gov (United States)

    O'Connor, U; Gallagher, A; O'Reilly, G; Dowling, A; Malone, J F

    2013-02-01

    Radiological equipment must be assessed against criteria for acceptability to ensure that it meets the minimum standards for patient safety. This assessment is typically led by a medical physicist with input from radiology staff and the equipment supplier. Equipment that does not meet the criteria requires action and may be suspended from clinical use. European Commission report RP 91 will be revised and replaced as RP 162. It has been drawn up to aid medical physicists with the assessment process and provide guidance on suspension levels. This paper details several cases where the criteria in the proposed RP 162 were applied in general radiography, computed radiography, digital radiography and fluoroscopy. The factors considered by the medical physicist and the outcome of each case are presented. The proposed RP 162 report improves on its predecessor and provides a robust set of criteria for ensuring that patient safety within the EU medical exposures framework is optimised.

  17. Digital radiography in the aerospace industry

    Science.gov (United States)

    Buchanan, R. A.; Bueno, C.; Barry, R. C.; Barker, M. D.

    An account is given of the bases of digital radiography (DR), with a view to the identification of NDE systems with the greatest usefulness to the aerospace industry and the nature of the advanced image processing and reconstruction techniques that have been devised thus far. The spatial resolution of any DR system is fundamentally limited by the number of pixels in the digital image and the system field-of-view. Attention is given to the problems of image geometric unsharpness and radiation quantum noise limits, as well as to the potential role of advanced DR in future NDT of aerospace components.

  18. DIGITAL IMAGES PROCESSING IN RADIOGRAPHY

    OpenAIRE

    Pilař, Martin

    2010-01-01

    This thesis is focused primarily on digital image processing and modern imaging modalities algorithms. An algorithm means a method for solving a problem or an instruction. In image processing an algorithm presents the process from data acquisition to the resulting image displayed on the monitor. Therefore, in the first part of the thesis a brief overview of principles of imaging modalities used in radiodiagnostics is given. Collected data have to be analyzed and modelled in a certain way. The...

  19. DR with a DSLR: Digital Radiography with a Digital Single-Lens Reflex camera.

    Science.gov (United States)

    Fan, Helen; Durko, Heather L; Moore, Stephen K; Moore, Jared; Miller, Brian W; Furenlid, Lars R; Pradhan, Sunil; Barrett, Harrison H

    2010-02-15

    An inexpensive, portable digital radiography (DR) detector system for use in remote regions has been built and evaluated. The system utilizes a large-format digital single-lens reflex (DSLR) camera to capture the image from a standard fluorescent screen. The large sensor area allows relatively small demagnification factors and hence minimizes the light loss. The system has been used for initial phantom tests in urban hospitals and Himalayan clinics in Nepal, and it has been evaluated in the laboratory at the University of Arizona by additional phantom studies. Typical phantom images are presented in this paper, and a simplified discussion of the detective quantum efficiency of the detector is given.

  20. Comparison of the image quality of a high-resolution screen-film system and a digital flat panel detector system in avian radiography.

    Science.gov (United States)

    Bochmann, Monika; Ludewig, Eberhard; Krautwald-Junghanns, Maria-Elisabeth; Pees, Michael

    2011-01-01

    A conventional high-resolution screen-film system was compared with a digital detector system. A total of 20 birds (14 pigeons and six psittacine birds) with an average body mass of 533g were examined in dorsoventral as well as lateral projections. Digital radiographs were acquired with the same mAs as well as half the mAs used for the conventional radiographs. Three criteria and one overall assessment were defined for each of four anatomic regions and assessed by five veterinarians using a score system. Comparison of the ratings was done by visual grading analysis. For the majority of criteria, there was no significant difference regarding image quality between the digital and screen-film projections. However, for certain criteria the quality of the digital images was significantly superior. Using the same mAs as for the conventional radiographs, the humeral joint surfaces and the honeycomb structure of the lung were assessed as superior with the digital imaging system. The tracheal rings and the delineation of the trachea from the surrounding tissue were also superior with the digital system. Assessment of the trabecular structure of the humerus was superior when the full mAs was used compared with the reduced mAs. In conclusion the digital technique is equal or superior to the conventional screen-film high-resolution system for pet birds of a medium size. With some limitations, a dose reduction is possible with the digital system.

  1. Digital radiography: a quantitative approach

    Energy Technology Data Exchange (ETDEWEB)

    Retraint, F. [Universite de Technologie de Troyes, Troyes (France)

    2004-07-01

    'Full-text:' In a radiograph the value of each pixel is related to the material thickness crossed by the x-rays. Using this relationship, an object can be characterized by parameters such as depth, surface and volume. Assuming a locally linear detector response and using a radiograph of reference object, the quantitative thickness map of object can be obtained by applying offset and gain corrections. However, for an acquisition system composed of cooled CCD camera optically coupled to a scintillator screen, the radiographic image formation process generates some bias which prevent from obtaining the quantitative information: non uniformity of the x-ray source, beam hardening, Compton scattering, scintillator screen, optical system response. In a first section, we propose a complete model of the radiographic image formation process taking account of these biases. In a second section, we present an inversion scheme of this model for a single material object, which enables to obtain the thickness map of the object crossed by the x-rays. (author)

  2. Digital Radiography Qualification of Tube Welding

    Science.gov (United States)

    Carl, Chad

    2012-01-01

    The Orion Project will be directing Lockheed Martin to perform orbital arc welding on commodities metallic tubing as part of the Multi Purpose Crew Vehicle assembly and integration process in the Operations and Checkout High bay at Kennedy Space Center. The current method of nondestructive evaluation is utilizing traditional film based x-rays. Due to the high number of welds that are necessary to join the commodities tubing (approx 470), a more efficient and expeditious method of nondestructive evaluation is desired. Digital radiography will be qualified as part of a broader NNWG project scope.

  3. Digital radiography image quality: image processing and display.

    Science.gov (United States)

    Krupinski, Elizabeth A; Williams, Mark B; Andriole, Katherine; Strauss, Keith J; Applegate, Kimberly; Wyatt, Margaret; Bjork, Sandra; Seibert, J Anthony

    2007-06-01

    This article on digital radiography image processing and display is the second of two articles written as part of an intersociety effort to establish image quality standards for digital and computed radiography. The topic of the other paper is digital radiography image acquisition. The articles were developed collaboratively by the ACR, the American Association of Physicists in Medicine, and the Society for Imaging Informatics in Medicine. Increasingly, medical imaging and patient information are being managed using digital data during acquisition, transmission, storage, display, interpretation, and consultation. The management of data during each of these operations may have an impact on the quality of patient care. These articles describe what is known to improve image quality for digital and computed radiography and to make recommendations on optimal acquisition, processing, and display. The practice of digital radiography is a rapidly evolving technology that will require timely revision of any guidelines and standards.

  4. Measuring microfocus focal spots using digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Fry, David A [Los Alamos National Laboratory

    2009-01-01

    Measurement of microfocus spot size can be important for several reasons: (1) Quality assurance during manufacture of microfocus tubes; (2) Tracking performance and stability of microfocus tubes; (3) Determining magnification (especially important for digital radiography where the native spatial resolution of the digital system is not adequate for the application); (4) Knowledge of unsharpness from the focal spot alone. The European Standard EN 12543-5 is based on a simple geometrical method of calculating focal spot size from unsharpness of high magnification film radiographs. When determining microfocus focal spot dimensions using unsharpness measurements both signal-to-noise (SNR) and magnification can be important. There is a maximum accuracy that is a function of SNR and therefore an optimal magnification. Greater than optimal magnification can be used but it will not increase accuracy.

  5. Standard guide for digital detector array radiology

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This standard is a user guide, which is intended to serve as a tutorial for selection and use of various digital detector array systems nominally composed of the detector array and an imaging system to perform digital radiography. This guide also serves as an in-detail reference for the following standards: Practices E2597, , and E2737. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  6. Bacteriological research for the contamination of digital portable radiography

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Seong Gyu [Dept. of Radiology, Dong A University Hospital, Busan (Korea, Republic of); Lee, Hyo Yeong [Dept. of Radiological Science, Dong Eui University, Busan (Korea, Republic of)

    2017-03-15

    The study was performed to investigate the bacteriological contamination of portable digital radiography system and their detectors in a university hospital. CNS and VRE were detected in the samples collected from vinyl cover on detectors used for the infection control patients. On the other hand, no bacteria was detected in the samples collected from detectors with vinyl cover removed. In the series of imaging of patients from general wards, no bacteria was detected from the patient 1. However, CNS was detected from the patients 2 and 3, CNS and Enterococcus faecalis detected from the patient 4, CNS and Enterococcus casseliflavus detected from the patient 5, and CNS, Enterococcus casseliflavus, and Klebsiella pneumoniae all detected from the patient 6. CNS and Enterococcus faecium were detected in the controller handle of collimator. Also, CNS was detected from the handle of detector and exposure switch. In the treatment gloves of the radiological technologist after the imaging, CNS, Enterococcus gallinarum, and Klebsiella pneumoniae were detected. Therefore, it is recommended for DR portable to take images after sterilizing the detector after taking each image and to use disposable vinyl covers on detectors to remove after imaging. And treatment gloves must be changed after each imaging. Also, hospital infection via portables must be prevented by complete sterilization of the controller handles of collimator which are in frequent contact during imaging and infection education of employees.

  7. Digital image processing in neutron radiography

    CERN Document Server

    Körner, S

    2000-01-01

    automated neutron tomography facility has been built at the Atominstitut with this detector. Digital Image Processing: Due to special detector properties of the CCD-camera NR detector, a standard image processing procedure has been developed that always has to be applied, when the CCD-detector is used. It consists of the following steps: white spot correction - dark frame correction and flat field correction. Radiation, which hits the CCD-chip causes an overflow of one or several pixels, which appears in the image as white spots. These disturbing spots have to be removed by means of digital image processing. Several filters have been tested, but the results were insufficient. Therefore, a new threshold-median-mean value filter was designed and a proper code was written in IDL (interactive data language). The new filter removes white spots very well by hardly blurring the images. A dark frame is an image made with closed camera shutter. It contains undesired detector signal caused by read out noise and dark cu...

  8. The MU-RAY detector for muon radiography of volcanoes

    Energy Technology Data Exchange (ETDEWEB)

    Anastasio, A. [INFN-Napoli (Italy); Ambrosino, F. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Basta, D. [INFN-Napoli (Italy); Bonechi, L. [Università degli Studi di Firenze, Firenze (Italy); INFN-Firenze (Italy); Brianzi, M. [Università degli Studi di Firenze, Firenze (Italy); Bross, A. [Fermilab (United States); Callier, S. [LAL, Orsay (France); Caputo, A. [INGV Osservatorio Vesuviano, Napoli (Italy); Ciaranfi, R. [INFN-Firenze (Italy); Cimmino, L. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); D' Alessandro, R. [Università degli Studi di Firenze, Firenze (Italy); INFN-Firenze (Italy); D' Auria, L. [INGV Osservatorio Vesuviano, Napoli (Italy); La Taille, C. de [LAL, Orsay (France); Energico, S. [CNR- SPIN, Napoli (Italy); INFN-Napoli (Italy); Garufi, F. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Giudicepietro, F. [INGV Osservatorio Vesuviano, Napoli (Italy); Lauria, A. [INFN-Napoli (Italy); Università Federico II, Napoli (Italy); Macedonio, G.; Martini, M. [INGV Osservatorio Vesuviano, Napoli (Italy); Masone, V. [Università Federico II, Napoli (Italy); and others

    2013-12-21

    The MU-RAY detector has been designed to perform muon radiography of volcanoes. The possible use on the field introduces several constraints. First the electric power consumption must be reduced to the minimum, so that the detector can be solar-powered. Moreover it must be robust and transportable, for what concerns the front-end electronics and data acquisition. A 1 m{sup 2} prototype has been constructed and is taking data at Mt. Vesuvius. The detector consists of modules of 32 scintillator bars with wave length shifting fibers and silicon photomultiplier read-out. A dedicated front-end electronics has been developed, based on the SPIROC ASIC. An introduction to muon radiography principles, the MU-RAY detector description and results obtained in laboratory will be presented.

  9. Turnover Rate Simulation Using GEM Detector on Neutron Radiography

    Institute of Scientific and Technical Information of China (English)

    SHAN; Chao; LI; Xiao-mei; HU; Shou-yang; ZHOU; Jing; JIAN; Si-yu; BAI; Xin-zhan; YE; Li; ZHOU; Shu-hua

    2012-01-01

    <正>With the advantages of high counting rate, high resolution ratio and high compatibility, GEM (Gas Electron Multiplier) detector has becoming the hot topic in the field of gas detector. Using GEM on neutron radiography, we need a suitable neutron converter. By the action on the converter and ingoing neutron, the outgoing particles could be an alpha or proton, which are charged particles. The charged

  10. Experiments on muon radiography with emulsion track detectors

    Directory of Open Access Journals (Sweden)

    Aleksandrov Andrey

    2016-01-01

    Full Text Available Muon radiography is a method of study the internal structure of large natural and industrial objects based on sensing an object with a flux of cosmic muons with their subsequent registration and analysis of the pattern of their dispersion, or conplete (or partial absorption. The Lebedev Physical Institute of the Russian Academy of Sciences and the Skobeltsyn Institute of Nuclear Physics of Moscow State University have started a series of muon radiography experiments with nuclear emulsion detectors. As a result, the optimal conditions for experiment arrangement have been determined, algorithms of data processing have been worked out, and peculiarities of the method have been ultimately investigated.

  11. Distinguishing materials in inspected objects by digital radiography

    Science.gov (United States)

    Ryzhikov, V.; Lysetska, O.; Opolonin, A.; Danilenko, V.; Galkin, S.; Voronkin, E.; Kostyukevich, S. A.

    2005-08-01

    We used detector arrays of types "scintillator-photodiode" (S-PD) and scintillator-photoreceiving device (PRD). In non-destructive testing systems using S-PD arrays it is possible to use scintillators of different atomic number and density, which allows functioning in the energy range from 20 keV to 10 MeV, i.e., steel equivalent thickness I from 100μm to 300mm. For different objects and different purposes, different types of detector arrays and methods of control can be recommended. Results of experimental studies of detector arrays S-PD and S-PRD used for X-ray digital radiography have shown that there exist further possibilities to increase spatial resolution of this system for up to 2-3 line pairs per mm. It was investigated experimental results with used two array detectors for low-energy and high - energy detections (HED and LED). It is show in principle to distinguish not only organic from inorganic materials, but so as safety organic from explosive. Our aim was to show (theoretically and experimentally) that is could be possible to substantially increase the accuracy of separation of substances in the inspected object by their atomic number, as well as to increase the sensitivity of the method as a whole by using a multi-energy approach and detectors that have substantially different sensibility in the low-and high-energy range of the X-ray emitter spectrum. It was show the possibility to distinct materials with effective atomic number difference about 10-15%. It can be used in inspection systems, including anti-terrorist activities, in technical diagnostics, medicine.

  12. High efficiency gaseous tracking detector for cosmic muon radiography

    CERN Document Server

    Varga, Dezső; Hamar, Gergő; Oláh, László

    2016-01-01

    A tracking detector system has been constructed with an innovative approach to the classical multi-wire proportional chamber concept, using contemporary technologies. The detectors, covering an area of 0.58 square meters each, are optimized for the application of muon radiography. The main features are high (>99.5%) and uniform detection efficiency, 9 mm FWHM position resolution, filling gas consumption below 2 liters per hour for the non toxic, non flammable argon and carbon dioxide mixture. These parameters, along with the simplicity of the construction and the tolerance for mechanical effects, make the detectors to be a viable option for a large area muography observation system.

  13. First results on proton radiography with nuclear emulsion detectors

    CERN Document Server

    Braccini, S; Kreslo, I; Moser, U; Pistillo, C; Studer, S; Scampoli, P; Coray, A; Pedroni, E

    2010-01-01

    We propose an innovative method for proton radiography based on nuclear emulsion film detectors, a technique in which images are obtained by measuring the position and the residual range of protons passing through the patient's body. For this purpose, nuclear emulsion films interleaved with tissue equivalent absorbers can be used to reconstruct proton tracks with very high accuracy. This is performed through a fully automated scanning procedure employing optical microscopy, routinely used in neutrino physics experiments. Proton radiography can be used in proton therapy to obtain direct information on the average tissue density for treatment planning optimization and to perform imaging with very low dose to the patient. The first prototype of a nuclear emulsion based detector has been conceived, constructed and tested with a therapeutic proton beam. The first promising experimental results have been obtained by imaging simple phantoms.

  14. Accurate MTF measurement in digital radiography using noise response

    Energy Technology Data Exchange (ETDEWEB)

    Kuhls-Gilcrist, Andrew; Jain, Amit; Bednarek, Daniel R.; Hoffmann, Kenneth R.; Rudin, Stephen [Toshiba Stroke Research Center, University at Buffalo, State University of New York, Biomedical Research Building, Room 445, 3435 Main Street, Buffalo, New York 14214 (United States)

    2010-02-15

    Purpose: The authors describe a new technique to determine the system presampled modulation transfer function (MTF) in digital radiography using only the detector noise response. Methods: A cascaded-linear systems analysis was used to develop an exact relationship between the two-dimensional noise power spectrum (NPS) and the presampled MTF for a generalized detector system. This relationship was then utilized to determine the two-dimensional presampled MTF. For simplicity, aliasing of the correlated noise component of the NPS was assumed to be negligible. Accuracy of this method was investigated using simulated images from a simple detector model in which the ''true'' MTF was known exactly. Measurements were also performed on three detector technologies (an x-ray image intensifier, an indirect flat panel detector, and a solid state x-ray image intensifier), and the results were compared using the standard edge-response method. Flat-field and edge images were acquired and analyzed according to guidelines set forth by the International Electrotechnical Commission, using the RQA 5 spectrum. Results: The presampled MTF determined using the noise-response method for the simulated detector system was in close agreement with the true MTF with an averaged percent difference of 0.3% and a maximum difference of 1.1% observed at the Nyquist frequency (f{sub N}). The edge-response method of the simulated detector system also showed very good agreement at lower spatial frequencies (less than 0.5 f{sub N}) with an averaged percent difference of 1.6% but showed significant discrepancies at higher spatial frequencies (greater than 0.5 f{sub N}) with an averaged percent difference of 17%. Discrepancies were in part a result of noise in the edge image and phasing errors. For all three detector systems, the MTFs obtained using the two methods were found to be in good agreement at spatial frequencies less than 0.5 f{sub N} with an averaged percent difference of 3

  15. Vibration Analysis of Digital Radiography System for Large Container Inspection

    Institute of Scientific and Technical Information of China (English)

    黄松岭; 李路明; 周立业; 向新程; 安继刚

    2003-01-01

    The cantilever vibration characteristics of a digital radiography system were analyzed to predict the effect of vibration on the performance of a mobile container inspection system. The static deformation,vibration mode and natural frequency of the cantilever of the digital radiography system were calculated with the ALGOR Finite Element System to verify the strength and rigidity of the cantilever. The maximum amplitude of the cantilever vibration occurs as it starts accelerating. The predictions show good agreement with test results, indicating that the finite element model of the cantilever structure accurately models the mechanical characteristics.

  16. Generalized two-dimensional (2D) linear system analysis metrics (GMTF, GDQE) for digital radiography systems including the effect of focal spot, magnification, scatter, and detector characteristics

    Science.gov (United States)

    Kuhls-Gilcrist, Andrew T.; Gupta, Sandesh K.; Bednarek, Daniel R.; Rudin, Stephen

    2010-01-01

    The MTF, NNPS, and DQE are standard linear system metrics used to characterize intrinsic detector performance. To evaluate total system performance for actual clinical conditions, generalized linear system metrics (GMTF, GNNPS and GDQE) that include the effect of the focal spot distribution, scattered radiation, and geometric unsharpness are more meaningful and appropriate. In this study, a two-dimensional (2D) generalized linear system analysis was carried out for a standard flat panel detector (FPD) (194-micron pixel pitch and 600-micron thick CsI) and a newly-developed, high-resolution, micro-angiographic fluoroscope (MAF) (35-micron pixel pitch and 300-micron thick CsI). Realistic clinical parameters and x-ray spectra were used. The 2D detector MTFs were calculated using the new Noise Response method and slanted edge method and 2D focal spot distribution measurements were done using a pin-hole assembly. The scatter fraction, generated for a uniform head equivalent phantom, was measured and the scatter MTF was simulated with a theoretical model. Different magnifications and scatter fractions were used to estimate the 2D GMTF, GNNPS and GDQE for both detectors. Results show spatial non-isotropy for the 2D generalized metrics which provide a quantitative description of the performance of the complete imaging system for both detectors. This generalized analysis demonstrated that the MAF and FPD have similar capabilities at lower spatial frequencies, but that the MAF has superior performance over the FPD at higher frequencies even when considering focal spot blurring and scatter. This 2D generalized performance analysis is a valuable tool to evaluate total system capabilities and to enable optimized design for specific imaging tasks. PMID:21243038

  17. Digital radiography: update for oral health care workers.

    Science.gov (United States)

    Noffke, C E E; Nzima, N; Chabikuli, N J

    2004-08-01

    Digital Radiography is an imaging system that does away with the use of films. It constitutes an advance in computer technology and has made a significant impact on the field of Maxillofacial- and Dental Radiology. This paper presents an overview of the basic concepts and applications of dental digital radiography and compares it with conventional film-based imaging. In addition, it provides a thorough understanding of the direct, semi-direct and indirect dental digital imaging systems with their advantages and disadvantages. Universal acceptance of digital radiographic imaging as a diagnostic tool makes it important for oral health care workers to understand the principles thereof and to master the techniques involved in acquiring a diagnosable digital radiographic image.

  18. Application of digital radiography in the analysis of cultural heritage

    Energy Technology Data Exchange (ETDEWEB)

    Oiveira, Davi F.; Calza, Cristiane; Rocha, Henrique S.; Nascimento, Joseilson R.; Lopes, Ricardo T., E-mail: davi@lin.ufrj.br, E-mail: ccalza@lin.ufrj.br, E-mail: henrique@lin.ufrj.br, E-mail: joseilson@lin.ufrj.br, E-mail: ricardo@lin.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentacao Nuclear

    2013-07-01

    The scientific examination of artworks has gained increasing interest in the last years, allowing the characterization of materials and techniques employed by the artists. This analysis can be extremely valuable to conservation and restoration treatments. However, the fact that every artworks is a unique piece emphasizes the necessity of working with non-destructive techniques. Although radiography has been used in the technical examination of museum objects for many decades, digital radiography is rapidly becoming a preferred modality for this essential tool in the advanced examination of works of art. The ability to electronically combine images from the large painting into a single composite image file was extremely valuable and results in higher quality images than those achieved with conventional radiography. These images can be also processed and improved using adequate software. Additional advantages of digital radiography include the possibility of an almost immediate analysis of the results, use of an only recording film and absence of chemical processing. Radiographic imaging can be applied to the analysis of virtually all media including paintings, sculptures, woodworks, engravings, etc. This paper reports some case studies of the use of digital radiography in the study of paintings and sculptures, showing the feasibility and advantages of this technique for this kind of purpose. The radiographic images revealed the conservation state of the analyzed objects and various details of its execution in order to assist recently restoration processes. (author)

  19. Digital Radiography and Computed Tomography (DRCT) Product Improvement Plan (PIP)

    Energy Technology Data Exchange (ETDEWEB)

    Tim Roney; Bob Pink; Karen Wendt; Robert Seifert; Mike Smith

    2010-12-01

    The Idaho National Laboratory (INL) has been developing and deploying x-ray inspection systems for chemical weapons containers for the past 12 years under the direction of the Project Manager for Non-Stockpile Chemical Materiel (PMNSCM). In FY-10 funding was provided to advance the capabilities of these systems through the DRCT (Digital Radiography and Computed Tomography) Product Improvement Plan (PIP), funded by the PMNSCM. The DRCT PIP identified three research tasks; end user study, detector evaluation and DRCT/PINS integration. Work commenced in February, 2010. Due to the late start and the schedule for field inspection of munitions at various sites, it was not possible to spend sufficient field time with operators to develop a complete end user study. We were able to interact with several operators, principally Mr. Mike Rowan who provided substantial useful input through several discussions and development of a set of field notes from the Pueblo, CO field mission. We will be pursuing ongoing interactions with field personnel as opportunities arise in FY-11.

  20. Application of imaging plate neutron detector to neutron radiography

    CERN Document Server

    Fujine, S; Kamata, M; Etoh, M

    1999-01-01

    As an imaging plate neutron detector (IP-ND) has been available for thermal neutron radiography (TNR) which has high resolution, high sensitivity and wide range, some basic characteristics of the IP-ND system were measured at the E-2 facility of the KUR. After basic performances of the IP were studied, images with high quality were obtained at a neutron fluence of 2 to 7x10 sup 8 n cm sup - sup 2. It was found that the IP-ND system with Gd sub 2 O sub 3 as a neutron converter material has a higher sensitivity to gamma-ray than that of a conventional film method. As a successful example, clear radiographs of the flat view for the fuel side plates with boron burnable poison were obtained. An application of the IP-ND system to neutron radiography (NR) is presented in this paper.

  1. Digital X-Radiography Scanning Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Generates digital X-radiographic images of sediment cores that portray density variations, sediment stratigraphy, bioturbation, and inclusions.DESCRIPTION:...

  2. Digital radiography and advanced imaging techniques in dentistry

    Directory of Open Access Journals (Sweden)

    Burcu Keles Evlice

    2013-04-01

    Full Text Available Since the discovery of x-rays in 1895, film has been the primary medium for capturing, displaying and storing radiographic images. Digital or filmless radiography is slowly being adopted by the dental profession. Digital radiography offers a number of capabilities compared with conventional radiography, such as postprocessing, electronic archiving, concurrent access to images, and improved data distribution. Computer based applications which are used for quantitative measurements and evaluations on digital images for better user interpretation. New diagnostic imaging processes are improved connected with the technological progress of computer systems. Since the first clinical use of computed tomography (CT scans in 1972, technological development has been rapid. Dental volumetric tomography (DVT, uniquely used for dentomaxillofacial imaging came to the market owing to recent rapid developments in digital radiology technology and is becoming more popular in dental applications. Low radiation dose cone beam computed tomography (CBCT units that are commercially available at a lower cost than CT units, has performed valuable diagnostic information for dentists. [Archives Medical Review Journal 2013; 22(2.000: 230-238

  3. Digital radiography in the evaluation of oesophageal motility disorders

    Energy Technology Data Exchange (ETDEWEB)

    Aly, Yehia A

    2000-07-01

    AIMS: To develop a simple technique for examination of the oesophagus by digital radiography and to assess its role in the evaluation of motility disorders of the oesophagus. MATERIALS AND METHODS: Forty-nine patients and 44 control subjects underwent manometry and digital examination of the oesophagus. The digital study consisted of two parts: firstly examination of the pharynx and cervical oesophagus using 15 ml of fluid barium in anterio-posterior (AP) and lateral views, with image acquisition of four frames/s for 2 s. Secondly, examination of the thoracic oesophagus and oesophagogastric junction using 25 ml of barium in two prone oblique and one supine AP series, with image acquisition of one frame/s for 20 s. Oesophageal transit time (OTT) was measured in each case. Abnormal or non-peristaltic contractions were described regarding their morphology, time of visualization and length. The presence or absence of hiatal hernia, reflux or any associated organic lesions was noted. RESULTS: Digital radiography diagnosed 14 cases of achalasia and 28 cases of non-specific oesophageal motility disorder (NOMD). Normal OTT was 11.95 {+-} 1.304 s. The OTT was prolonged (16 s or more) in all patients except five; four of these were cases of NOMD. Abnormal contractions were classified into circular and longitudinal types. The circular non-obliterating type was commoner. Achalasia was diagnosed in all cases, as failure of relaxation of the inferior oesophageal sphincter was always present and easily depicted by digital radiography. Abnormal contractions in the body of the oesophagus were elicited in 57% of cases of achalasia. The sensitivity of digital radiography in detecting oesophageal motility disorders was 85.7% based on the presence of abnormal contractions and 91.6% by eliciting a prolonged OTT. CONCLUSIONS: Examination of the oesophagus by digital radiography is simple, non-invasive, reproducible, rapid and without discomfort to patients. It allows the diagnosis of

  4. Review and Prospect of Cobalt-60 Digital Radiography Inspection Technology

    OpenAIRE

    AN Ji-gang

    2015-01-01

    This article is a review and prospect of the research, development and industrialization of Cobalt-60 digital radiography inspection technology based on the national requirements in the recent 20 years, which is leaded by Institute of Nuclear and New Energy Technology (INET) of TsinghuaUniversity. The research purpose, innovative approach and main academic achievements of this technology were described systematically. The industrial equipment varieties, performance, running condition and appl...

  5. Practical contour segmentation algorithm for small animal digital radiography image

    Science.gov (United States)

    Zheng, Fang; Hui, Gong

    2008-12-01

    In this paper a practical, automated contour segmentation technique for digital radiography image is described. Digital radiography is an imaging mode based on the penetrability of x-ray. Unlike reflection imaging mode such as visible light camera, the pixel brightness represents the summation of the attenuations on the photon thoroughfare. It is not chromophotograph but gray scale picture. Contour extraction is of great importance in medical applications, especially in non-destructive inspection. Manual segmentation techniques include pixel selection, geometrical boundary selection and tracing. But it relies heavily on the experience of the operators, and is time-consuming. Some researchers try to find contours from the intensity jumping characters around them. However these characters also exist in the juncture of bone and soft tissue. The practical way is back to the primordial threshold algorithm. This research emphasizes on how to find the optimal threshold. A high resolution digital radiography system is used to provide the oriental gray scale image. A mouse is applied as the sample of this paper to show the feasibility of the algorithm.

  6. Digital contrast subtraction radiography for proximal caries diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Byung Cheol; Yoon, Suk Ja [Department of Dental Radiology, Chonnam National University Hospital, Gwangju (Korea, Republic of)

    2002-06-15

    To determine whether subtraction images utilizing contrast media can improve the diagnostic performance of proximal caries diagnosis compared to conventional periapical radiographic images. Thirty-six teeth with 57 proximal surfaces were radiographied using a size no.2 RVG-ui sensor (Trophy Radiology, Marne-la-Vallee, France). The teeth immersed in water-soluble contrast media and subtraction images were taken. Each tooth was then sectioned for histologic examination. The digital radiographic images and subtraction images were examined and interpreted by three dentists for proximal caries. The results of the proximal caries diagnosis were then verified with the results of the histologic examination. The proximal caries sensitivity using digital subtraction radiography was significantly higher than simply examining a single digital radiograph. The sensitivity of the proximal dentinal carious lesion when analyzed with the subtraction radiograph and the radiograph together was higher than with the subtraction radiograph or the radiograph alone. The use of subtraction radiography with contrast media may be useful for detecting proximal dentinal carious lesions.

  7. Multiscale image processing and antiscatter grids in digital radiography.

    Science.gov (United States)

    Lo, Winnie Y; Hornof, William J; Zwingenberger, Allison L; Robertson, Ian D

    2009-01-01

    Scatter radiation is a source of noise and results in decreased signal-to-noise ratio and thus decreased image quality in digital radiography. We determined subjectively whether a digitally processed image made without a grid would be of similar quality to an image made with a grid but without image processing. Additionally the effects of exposure dose and of a using a grid with digital radiography on overall image quality were studied. Thoracic and abdominal radiographs of five dogs of various sizes were made. Four acquisition techniques were included (1) with a grid, standard exposure dose, digital image processing; (2) without a grid, standard exposure dose, digital image processing; (3) without a grid, half the exposure dose, digital image processing; and (4) with a grid, standard exposure dose, no digital image processing (to mimic a film-screen radiograph). Full-size radiographs as well as magnified images of specific anatomic regions were generated. Nine reviewers rated the overall image quality subjectively using a five-point scale. All digitally processed radiographs had higher overall scores than nondigitally processed radiographs regardless of patient size, exposure dose, or use of a grid. The images made at half the exposure dose had a slightly lower quality than those made at full dose, but this was only statistically significant in magnified images. Using a grid with digital image processing led to a slight but statistically significant increase in overall quality when compared with digitally processed images made without a grid but whether this increase in quality is clinically significant is unknown.

  8. Image quality and exposure dose in digital projection radiography; Bildqualitaet und Dosis in der Digitalen Projektionsradiographie

    Energy Technology Data Exchange (ETDEWEB)

    Busch, H.P.; Busch, S.; Decker, C.; Schilz, C. [Krankenhaus der Barmherzigen Brueder Trier, Abt. fuer Radiologie, Trier (Germany)

    2003-01-01

    Purpose: Comparison of the imaging capabilities of storage phosphor (computed) radiography and flat plate radiography with conventional film-screen radiography to find new strategies for quality and dose management, i.e., optimizing imaging quality and dose depending on the imaging method and clinical situation. Materials and Methods: Images of a CDRAD-phantom, hand-phantom, abdomen-phantom and chest-phantom obtained with different exposure voltages (50 kV, 73 kV, 109 kV) and different speeds (200, 400, 800, 1600) were processed with various digital systems (flat plate detector: Digital Diagnost [Philips]; storage phosphors: ADC-70 [Agfa], ADC-Solo [Agfa], FCR XG 1 [Fuji]) and a conventional film-screen system (HT100G/Ortho Regular [Agfa]). Results: The evaluation of CDRAD images found the flat plate detector system to have the highest contrast detectability for all dose levels, followed by the FCR XG 1, ADC-Solo and ADC-70 systems. Comparison of the organ-phantom images found the flat plate detector system to be equal to film-screen radiography and especially to storage phosphor systems even for low exposure doses. Conclusions: Flat plate radiography systems demonstrate the highest potential for high image quality when reducing the exposure dose. Depending on the system generation, the storage phosphor systems also show an improved image quality, but the possibility of a dose reduction is limited in comparison with the flat plate detector system. (orig.) [German] Ziel: Die vergleichende Darstellung der Abbildungseigenschaften verschiedener Speicherfoliengeraete und einer Flachdetektoranlage mit Film/Folienaufnahmen kann zu neuen Strategien des Qualitaets- und Dosismanagements fuehren, d.h. zu einer Optimierung von Bildqualitaet und Dosis in Abhaengigkeit von der Untersuchungsmethode und der klinischen Fragestellung. Methode: Aufnahmen von einem CDRAD-Phantom, Handphantom, Abdomenphantom und Thoraxphantom wurden mit verschiedenen digitalen Systemen (Flachdetektor

  9. Detectability of simulated vessels by computed radiography and digital fluorography

    Energy Technology Data Exchange (ETDEWEB)

    Misumi, Wataru; Yoshioka, Senya; Korogi, Yukunori; Takahashi, Mutsumasa (Kumamoto Univ. (Japan). School of Medicine); Higashida, Yoshiharu

    1990-05-01

    Phantom studies were carried out to determine the ability to digital subtraction angiography (DSA), using either Fuji computed radiography (CR) or digital fluorography (DF) system, to detect the simulated vessels. The assessment of detectability was based on observer performance techniques. DFDSA was superior to CRDSA. Detectability of CRDSA was influenced by the incident X-ray exposures. Even though it was improved by contrast enhancement, the magnitude of improvement was dependent upon the incident X-ray exposures and vessel size. (N.K.).

  10. The Enhanced Workflow and Efficiency of the Wireless Local Area Network (WLAN)-Based Direct Digital Radiography (DDR) Portable Radiography.

    Science.gov (United States)

    Ngan, Tsz-Lung; Wong, Edward Ting-Hei; Ng, Kris Lap-Shun; Jeor, Patrick Kwok-Shing; Lo, Gladys Goh

    2015-06-01

    With the implementation of the PACS in the hospital, there is an increasing demand from the clinicians for immediate access and display of radiological images. Recently, our hospital has installed the first wireless local area network (WLAN)-based direct digital radiography (DDR) portable radiography system. The DDR portable radiography system allows wireless retrieval of modality worklist and wireless transmission of portable X-ray image on the console to the Picture Archiving and Communication System (PACS), via WLAN connection of wireless fidelity (Wi-Fi). The aim of this study was to analyze the workflow and performance between the WLAN-based DDR portable radiography system and the old practice using conventional portable X-ray machine with computed radiography (CR) system. A total of 190 portable chest X-ray examinations were evaluated and timed, using the conventional portable X-ray machine with CR from March to April of 2012 and using the new DDR portable radiography system on December of 2012 (n = 97 for old system and n = 93 for DDR portable system). The time interval of image becoming available to the PACS using the WLAN-based DDR portable radiography system was significantly shorter than that of the old practice using the conventional portable X-ray machine with CR (6.8 ± 2.6 min for DDR portable system; 23 ± 10.2 min for old system; p DDR portable radiography system can enhance the workflow of portable radiography by reduction of procedural steps.

  11. A new scanner for in situ digital radiography of paintings

    Science.gov (United States)

    Impallaria, Anna; Evangelisti, Federico; Petrucci, Ferruccio; Tisato, Flavia; Castelli, Lisa; Taccetti, Francesco

    2016-12-01

    X-ray radiography is one of the most widely used imaging techniques in the field of cultural heritage, both for conservation and for investigation purposes. Performing radiographies in museums, thus avoiding movements of works of art, has been recently made easy by digital acquisition of images, but when the whole scan of a large painting is required, technical solutions for a portable device are still not at hand. The inherent weight of the X-ray tube and of the high-voltage generator makes the design of a portable device very difficult. In this project, the solution of the puzzle was separating devices devoted to different tasks, in order to maintain each item under 60 kg weight, thus being transportable with reasonable effort.

  12. A new scanner for in situ digital radiography of paintings

    Energy Technology Data Exchange (ETDEWEB)

    Impallaria, Anna; Petrucci, Ferruccio; Tisato, Flavia [University of Ferrara, Department of Physics and Earth Science, Ferrara (Italy); TekneHub Ferrara, Ferrara (Italy); INFN-Sezione di Ferrara, Ferrara (Italy); Evangelisti, Federico [University of Ferrara, Department of Physics and Earth Science, Ferrara (Italy); INFN-Sezione di Ferrara, Ferrara (Italy); Castelli, Lisa; Taccetti, Francesco [INFN-Sezione di Firenze, Sesto Fiorentino (Italy)

    2016-12-15

    X-ray radiography is one of the most widely used imaging techniques in the field of cultural heritage, both for conservation and for investigation purposes. Performing radiographies in museums, thus avoiding movements of works of art, has been recently made easy by digital acquisition of images, but when the whole scan of a large painting is required, technical solutions for a portable device are still not at hand. The inherent weight of the X-ray tube and of the high-voltage generator makes the design of a portable device very difficult. In this project, the solution of the puzzle was separating devices devoted to different tasks, in order to maintain each item under 60 kg weight, thus being transportable with reasonable effort. (orig.)

  13. Evaluation of diagnostic ability of CCD digital radiography in the detection of incipient dental caries

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Wan; Lee, Byung Do [Wonkwang University College of Medicine, Iksan (Korea, Republic of)

    2003-03-15

    The purpose of this experiment was to evaluate the diagnostic ability of a CCD-based digital system (CDX-2000HQ) in the detection of incipient dental caries. 93 extracted human teeth with sound proximal surfaces and interproximal artificial cavities were radiographed using 4 imaging methods. Automatically processed No.2 Insight film (Eastman Kodak Co., U.S.A.) was used for conventional radiography, scanned images of conventional radiograms for indirect digital radiography were used. For the direct digital radiography, the CDX-2000HQ CCD system (Biomedisys Co. Korea) was used. The subtraction images were made from two direct digital images by Sunny program in the CDX-2000HQ system. Two radiologists and three endodontists examined the presence of lesions using a five-point confidence scale and compared the diagnostic ability by ROC (Receiver Operating Characteristic) analysis and one way ANOVA test. The mean ROC areas of conventional radiography, indirect digital radiography, direct digital radiography, and digital subtraction radiography were 0.9093, 0.9102, 0.9184, and 0.9056, respectively. The diagnostic ability of direct digital radiography was better than the other imaging modalities, but there were no statistical differences among these imaging modalities (p>0.05). These results indicate that new CCD-based digital systems (CDX-2000HQ) have the potential to serve as an alternative to conventional radiography in the detection of incipient dental caries.

  14. Comparison of the diagnostic accuracy of direct digital radiography system, filtered images, and subtraction radiography

    Directory of Open Access Journals (Sweden)

    Wilton Mitsunari Takeshita

    2013-01-01

    Full Text Available Background: To compare the diagnostic accuracy of three different imaging systems: Direct digital radiography system (DDR-CMOS, four types of filtered images, and a priori and a posteriori registration of digital subtraction radiography (DSR in the diagnosis of proximal defects. Materials and Methods: The teeth were arranged in pairs in 10 blocks of vinyl polysiloxane, and proximal defects were performed with drills of 0.25, 0.5, and 1 mm diameter. Kodak RVG 6100 sensor was used to capture the images. A posteriori DSR registrations were done with Regeemy 0.2.43 and subtraction with Image Tool 3.0. Filtered images were obtained with Kodak Dental Imaging 6.1 software. Images (n = 360 were evaluated by three raters, all experts in dental radiology. Results: Sensitivity and specificity of the area under the receiver operator characteristic (ROC curve (Az were higher for DSR images with all three drills (Az = 0.896, 0.979, and 1.000 for drills 0.25, 0.5, and 1 mm, respectively. The highest values were found for 1-mm drills and the lowest for 0.25-mm drills, with negative filter having the lowest values of all (Az = 0.631. Conclusion: The best method of diagnosis was by using a DSR. The negative filter obtained the worst results. Larger drills showed the highest sensitivity and specificity values of the area under the ROC curve.

  15. Digital luminescent radiography for diagnosis of skeletal injuries

    Energy Technology Data Exchange (ETDEWEB)

    Buddenbrock, B. [Central Inst. for Radiological Diagnostics, University Hospital of GHS Essen (Germany); Mueller, R.D. [Central Inst. for Radiological Diagnostics, University Hospital of GHS Essen (Germany); John, V. [Central Inst. for Radiological Diagnostics, University Hospital of GHS Essen (Germany); Kock, H.J. [Dept. of Traumatology, University Hospital of GHS Essen (Germany); Hirche, H. [Inst. of Medical Informatics and Biomathematics, Univ. Hospital of GHS Essen (Germany); Voss, M. [Central Inst. for Radiological Diagnostics, University Hospital of GHS Essen (Germany); Loehr, E. [Central Inst. for Radiological Diagnostics, University Hospital of GHS Essen (Germany); Schmit-Neuerburg, K.P. [Dept. of Traumatology, University Hospital of GHS Essen (Germany)

    1992-12-01

    In the course of a comparative study 231 patients with traumatic lesions in skeletal and soft tissue areas were X-rayed using conventional film radiography and digital luminescence radiography (DLR). The results were evaluated by radiologists and traumatologists on the basis of optimised image post-processing in addition to the standard digital presentations. The imaging quality of compacta, spongiosa, soft tissues, fracture lines and osteosynthesis material was assessed in comparison with the screen-film images. Whereas the standard digital presentation in the ``conventionally adjusted`` imaging mode was inferior to the screen-film radiograph, the ``edge-enhanced`` standard presentation proved to be advantageous in the imaging of soft tissues (frequency of first-place ratings: DLR conventional 6%, screen-film system 21%, DLR edge-enhanced 31%). In the overall evaluation high-frequency filtered inverse image post-processing showed the highest diagnostic potential (frequency of first-place ratings: 41%). A conclusive assessment of metal implants is hindered by overshoot artefacts and can only be achieved through time-consuming post-processing of the stored image data. (orig.)

  16. A note on digital dental radiography in forensic odontology.

    Science.gov (United States)

    Chiam, Sher-Lin

    2014-09-01

    Digital dental radiography, intraoral and extraoral, is becoming more popular in dental practice. It offers convenience, such as lower exposure to radiation, ease of storing of images, and elimination of chemical processing. However, it also has disadvantages and drawbacks. One of these is the potential for confusion of the orientation of the image. This paper outlines one example of this, namely, the lateral inversion of the image. This source of confusion is partly inherent in the older model of phosphor storage plates (PSPs), as they allow both sides to be exposed without clue to the fact that the image is acquired on the wrong side. The native software allows digital manipulation of the X-ray image, permitting both rotation and inversion. Attempts to orientate the X-ray according to the indicator incorporated on the plate can then sometimes lead to inadvertent lateral inversion of the image. This article discusses the implications of such mistakes in dental digital radiography to forensic odontology and general dental practice.

  17. Building a cost efficient digital radiography system for educational purposes

    Science.gov (United States)

    Brown, Chris

    Due to the growing need for Medical Physicists, many universities are implementing a Medical Physics program into their academic catalog. To help establish a new program, feasible equipment may be needed to help academic departments provide a hands-on experience for students and help teach the basic concepts of Medical Physics. For example, clinical Digital Radiography Systems (DRS) are used to help teach the basic concepts of digital imaging. However, such systems can cost in excess of 100,000, creating a financial obstacle that will be difficult to overcome. Hence, the development of a cost efficient digital radiography system may be desired in order to eliminate the financial obstacle and give students a hands-on learning experience. This DRS uses three main components to develop an image, an x-ray source, an intensifying plate, and a charge-coupled device (CCD) camera. All three components are housed in a lead-lined box. The purpose of this project is to find the limitations of our DRS and compare the price between our DRS and commercially available DRSs. At optimal settings, a SNR of 25 is shown across the intensifying screen that can identify objects as small as 0.42mm. A Contrast-detail phantom shows the ability to decipher the varying thickness of foam rubber squares. The total cost of our DRS comes to 17,000.00, a fractional price tag compared to a commercially available DRS.

  18. A note on digital dental radiography in forensic odontology

    Directory of Open Access Journals (Sweden)

    Sher-Lin Chiam

    2014-01-01

    Full Text Available Digital dental radiography, intraoral and extraoral, is becoming more popular in dental practice. It offers convenience, such as lower exposure to radiation, ease of storing of images, and elimination of chemical processing. However, it also has disadvantages and drawbacks. One of these is the potential for confusion of the orientation of the image. This paper outlines one example of this, namely, the lateral inversion of the image. This source of confusion is partly inherent in the older model of phosphor storage plates (PSPs, as they allow both sides to be exposed without clue to the fact that the image is acquired on the wrong side. The native software allows digital manipulation of the X-ray image, permitting both rotation and inversion. Attempts to orientate the X-ray according to the indicator incorporated on the plate can then sometimes lead to inadvertent lateral inversion of the image. This article discusses the implications of such mistakes in dental digital radiography to forensic odontology and general dental practice.

  19. Plasma technology and its use in flat panel digital radiography.

    Science.gov (United States)

    Zur, Albert

    2010-01-01

    Plasma DR technology is used to produce a cost effective flat panel x-ray detector that acquires digital x-ray images with excellent diagnostic quality. The detector is radiation hard and permanently zero defect, with a full virtual pixel matrix that has no dead lines, pixels, or dead pixel clusters. The technology also allows the full potential of large area amorphous Selenium imaging to finally be realized (see Figure 4).

  20. Digital radiography of the chest in pediatric patients; Die digitale Thoraxradiographie beim paediatrischen Patienten

    Energy Technology Data Exchange (ETDEWEB)

    Puig, S. [Universitaetsklinik fuer Radiodiagnostik, Wien (Austria)

    2003-12-01

    The hopes placed in digital radiography have been fulfilled only partly in pediatric radiology. Specifically, the option of gaining reduced radiation exposure in combination with a similar or even improved image quality was hard to realize. The only portable digital system available for a long time were storage phosphors which were disadvantaged by an extremely limited dose-quantum-efficiency (DQE) in comparison to digital flat panel detectors. New developments and the introduction of the dual-reading system led to image qualities comparable to film-screen-systems with high resolution and achievable without dose increase, sometimes even with dose reduction. A study using an animal model suggests that these systems can even be used in preterm infants with very low birth weights. A new portable flat panel detector by Canon may improve digital chest radiography in pediatric patients. (orig.) [German] Erwartungen, die man anfaenglich in die digitale Projektionsradiographie gesetzt hat, haben sich in der Kinderradiologie erst verzoegert oder teilweise gar nicht erfuellt. Insbesondere Hoffnungen, dass man die Strahlenbelastung bei gleich bleibender oder gar verbesserter Bildqualitaet reduzieren koennte, wurden bald enttaeuscht. Das einzige portable digitale System waren lange Zeit Phosphorplatten, die aber im Vergleich zu den Festplattendetektoren eine aeusserst limitierte Dosisquanteneffizienz (DQE) hatten. Durch neue Entwicklungen und v. a. durch die Einfuehrung des Dual-reading-Systems kann eine Bildqualitaet erreicht werden, die an hochaufloesende Film-Folien-Systeme heranreicht, ohne die Dosis erhoehen zu muessen. Teilweise ist nun auch eine Dosisreduktion moeglich. In einem Tiermodell konnte gezeigt werden, dass diese Systeme auch bei Fruehgeborenen mit einem sehr niedrigen Geburtgewicht einsetzbar sind. Hoffnung wird in ein neues portables Festplattendetektorsystem gesetzt, welches in der paediatrischen digitalen Thoraxradiographie evtl. neue Massstaebe setzen

  1. Quantitative evaluation of anatomical noise in chest digital tomosynthesis, digital radiography, and computed tomography

    Science.gov (United States)

    Lee, D.; Choi, S.; Lee, H.; Kim, D.; Choi, S.; Kim, H.-J.

    2017-04-01

    Lung cancer is currently the worldwide leading cause of death from cancer. Thus, detection of lung cancer at its early stages is critical for improving the survival rate of patients. Chest digital tomosynthesis (CDT) is a recently developed imaging modality, combining many advantages of digital radiography (DR) and computed tomography (CT). This method has the potential to be widely used in the clinical setting. In this study, we introduce a developed CDT R/F system and compare its image quality with those of DR and CT, especially with respect to anatomical noise and lung nodule conspicuity, for LUNGMAN phantoms. The developed CDT R/F system consists of a CsI scintillator flat panel detector, X-ray tube, and tomosynthesis data acquisition geometry. For CDT R/F imaging, 41 projections were acquired at different angles, over the ± 20° angular range, in a linear translation geometry. To evaluate the clinical effectiveness of the CDT R/F system, the acquired images were compared with CT (Philips brilliance CT 64, Philips healthcare, U.S.) and DR (ADR-M, LISTEM, Korea) phantom images in terms of the anatomical noise power spectrum (aNPS). DR images exhibited low conspicuity for a small-size lung nodule, while CDT R/F and CT exhibited relatively high sensitivity for all lung nodule sizes. The aNPS of the CDT R/F system was better than that of DR, by resolving anatomical overlapping problems. In conclusion, the developed CDT R/F system is likely to contribute to early diagnosis of lung cancer, while requiring a relatively low patient dose, compared with CT.

  2. Technical and clinical breast cancer screening performance indicators for computed radiography versus direct digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bosmans, Hilde; Lemmens, Kim; Zanca, Federica; Ongeval, Chantal van; Steen, Andre van [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Hauwere, An de; Thierens, Hubert [Ghent University, QCC, Ghent (Belgium); Herck, Koen van; Bleyen, Luc; Mortier, Griet [Ghent University, Centrum voor Preventie en Vroegtijdige Opsporing van Kanker, Department of Public Health, Ghent (Belgium); Martens, Patrick [Vroegtijdige Opsporing Borstklierkanker West-Vlaanderen vzw, Bruges (Belgium); Putte, Gretel vande; Kellen, Eliane; Limbergen, Erik van [Leuven University Center of Cancer Screening, Leuven (Belgium)

    2013-10-15

    To compare technical and clinical screening performance parameters between computed radiography (CR) and direct digital radiography (DR) systems. The number of women screened with CR was 73,008 and with DR 116,945. Technical and patient dose survey data of 25 CR and 37 DR systems were available. Technical performance was expressed by threshold thickness values at the mean glandular dose (MGD) level of routine practice. Clinical indicators included recall rate (RR), cancer detection rate (CDR), percentage of ductal carcinoma in situ (DCIS), percentage of cancers with T-scores smaller than 1 cm and positive predictive value (PPV). Contrast threshold values for the 0.1-mm gold disk were 1.44 {mu}m (SD 0.13 {mu}m) for CR and 1.20 {mu}m (SD 0.13 {mu}m for DR). MGD was 2.16 mGy (SD 0.36 mGy) and 1.35 mGy (SD 0.32 mGy) for CR and DR respectively. We obtained for CR, respectively DR, the following results: RR in the first round of 5.48 % versus 5.61 %; RR in subsequent rounds of 2.52 % versus 2.65 %; CDR of 0.52 % versus 0.53 %; DCIS of 0.08 % versus 0.11 %; a rate of cancers with T-scores smaller than 1 cm of 0.11 % versus 0.11 %; PPV of 18.45 % versus 18.64 %; none of them was significantly different. Our screening indicators are reassuring for the use of CR and DR, with CR operating at 60 % higher MGD. (orig.)

  3. Review and Prospect of Cobalt-60 Digital Radiography Inspection Technology

    Directory of Open Access Journals (Sweden)

    AN Ji-gang

    2015-11-01

    Full Text Available This article is a review and prospect of the research, development and industrialization of Cobalt-60 digital radiography inspection technology based on the national requirements in the recent 20 years, which is leaded by Institute of Nuclear and New Energy Technology (INET of TsinghuaUniversity. The research purpose, innovative approach and main academic achievements of this technology were described systematically. The industrial equipment varieties, performance, running condition and application effect were introduced, and the outstanding advantages and prospects of the technology are summarized. In the paper, some understanding obstacles or mistakes encountered during the promotion and application were sorted out and explained too to help the improvement and development of the new relevant technology.

  4. Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography

    Energy Technology Data Exchange (ETDEWEB)

    Dietrich, Tobias J.; Pfirrmann, Christian W.A.; Pankalla, Katja; Buck, Florian M. [Orthopedic University Hospital Balgrist, Department of Radiology, Zurich (Switzerland); University of Zurich, Zurich (Switzerland); Schwab, Alexander [University of Zurich, Zurich (Switzerland); Orthopedic University Hospital Balgrist, Department of Finances, Zurich (Switzerland)

    2013-07-15

    To compare the radiation dose, workflow, patient comfort, and financial break-even of a standard digital radiography and a biplanar low-dose X-ray system. A standard digital radiography system (Ysio, Siemens Healthcare, Erlangen, Germany) was compared with a biplanar X-ray unit (EOS, EOS imaging, Paris, France) consisting of two X-ray tubes and slot-scanning detectors, arranged at an angle of 90 allowing simultaneous vertical biplanar linear scanning in the upright patient position. We compared data of standing full-length lower limb radiographs and whole spine radiographs of both X-ray systems. Dose-area product was significantly lower for radiographs of the biplanar X-ray system than for the standard digital radiography system (e.g. whole spine radiographs; standard digital radiography system: 392.2 {+-} 231.7 cGy*cm{sup 2} versus biplanar X-ray system: 158.4 {+-} 103.8 cGy*cm{sup 2}). The mean examination time was significantly shorter for biplanar radiographs compared with standard digital radiographs (e.g. whole spine radiographs: 449 s vs 248 s). Patients' comfort regarding noise was significantly higher for the standard digital radiography system. The financial break-even point was 2,602 radiographs/year for the standard digital radiography system compared with 4,077 radiographs/year for the biplanar X-ray unit. The biplanar X-ray unit reduces radiation exposure and increases subjective noise exposure to patients. The biplanar X-ray unit demands a higher number of examinations per year for the financial break-even point, despite the lower labour cost per examination due to the shorter examination time. (orig.)

  5. A conceptual optimisation strategy for radiography in a digital environment.

    Science.gov (United States)

    Båth, Magnus; Håkansson, Markus; Hansson, Jonny; Månsson, Lars Gunnar

    2005-01-01

    Using a completely digital environment for the entire imaging process leads to new possibilities for optimisation of radiography since many restrictions of screen/film systems, such as the small dynamic range and the lack of possibilities for image processing, do not apply any longer. However, at the same time these new possibilities lead to a more complicated optimisation process, since more freedom is given to alter parameters. This paper focuses on describing an optimisation strategy that concentrates on taking advantage of the conceptual differences between digital systems and screen/film systems. The strategy can be summarised as: (a) always include the anatomical background during the optimisation, (b) perform all comparisons at a constant effective dose and (c) separate the image display stage from the image collection stage. A three-step process is proposed where the optimal setting of the technique parameters is determined at first, followed by an optimisation of the image processing. In the final step the optimal dose level-given the optimal settings of the image collection and image display stages-is determined.

  6. Location of mental foramen using digital panoramic radiography

    Directory of Open Access Journals (Sweden)

    Ajmal Mohamed

    2016-01-01

    Full Text Available Objective: Comparative evaluation of the location of mental foramen in different age groups. Determine the variation in position of mental foramen with gender using digital panoramic radiography. Materials and Methods: Digital panoramic radiographs of 250 patients were reviewed. The study population was divided into five age groups with 50 patients each. Radiographic position of mental foramen was evaluated in each radiograph based on three parameters. Measurements were taken in each radiograph using Planmeca Dimaxis pro version 4.4.0 (Helsinki, Finland. The collected data were subjected to statistical analysis using paired Student's t-test. Results: The mean distance of position of mental foramen showed a significant variation within the five age groups. In the first group, female patients showed an increase in mean distance of mental foramen position in relation to three parameters. From the second to fifth groups, male patient showed an increase in the mean distance of mental foramen position. The first and fifth group showed a reduced mean distance of mental foramen position when compared to other age groups. Conclusion: This study concluded that the position of mental foramen varies with age. There was a gender-related variation in position of mental foramen within the population too.

  7. Location of mental foramen using digital panoramic Radiography

    Science.gov (United States)

    Mohamed, Ajmal; Nataraj, Kannan; Mathew, Vinod B.; Varma, Beena; Mohamed, Shamil; Valappila, Nidhin J.; Meena, Aravind S.

    2016-01-01

    Objective: Comparative evaluation of the location of mental foramen in different age groups. Determine the variation in position of mental foramen with gender using digital panoramic radiography. Materials and Methods: Digital panoramic radiographs of 250 patients were reviewed. The study population was divided into five age groups with 50 patients each. Radiographic position of mental foramen was evaluated in each radiograph based on three parameters. Measurements were taken in each radiograph using Planmeca Dimaxis pro version 4.4.0 (Helsinki, Finland). The collected data were subjected to statistical analysis using paired Student's t-test. Results: The mean distance of position of mental foramen showed a significant variation within the five age groups. In the first group, female patients showed an increase in mean distance of mental foramen position in relation to three parameters. From the second to fifth groups, male patient showed an increase in the mean distance of mental foramen position. The first and fifth group showed a reduced mean distance of mental foramen position when compared to other age groups. Conclusion: This study concluded that the position of mental foramen varies with age. There was a gender-related variation in position of mental foramen within the population too. PMID:27555723

  8. Study of the neutron radiography characteristics for the solid state nuclear track detector Makrofol-DE

    CERN Document Server

    Pugliesi, R

    2002-01-01

    In this work, the track-etch method was employed for Neutron Radiography purposes. A combination of the Solid State Nuclear Track Detector Makrofol-DE with a natural boron converter screen has been used to register the image. The radiography characteristics such as, track size, track production rate, characteristic curves and spatial resolution, have been studied. The detectors were irradiated up to neutron exposures about 5x10 sup 1 sup 0 n/cm sup 2 , in a radiography facility installed at the IEA-R1 Nuclear Research Reactor, and etched in a KOH aqueous solution at a constant temperature of 70 deg. C. The obtained results were compared with those reported by other and discussed according to the theory of the image formation in solid state nuclear track detectors. The experimental conditions to obtain the best image contrast, and the corresponding value of the spatial resolution, were also determined.

  9. A survey of digital radiography practice in four South African teaching hospitals: an illuminative study

    Science.gov (United States)

    Nyathi, T; Chirwa, TF; van der Merwe, DG

    2010-01-01

    Purpose: The purpose of this study was to assess radiographer familiarity and preferences with digital radiography in four teaching hospitals and thereafter make recommendations in line with the migration from screen film to digital radiography. Materials and methods: A questionnaire was designed to collect data from either qualified or student radiographers from four teaching hospitals. From the four teaching hospitals, there were a total of 205 potential respondents. Among other things, responses regarding experiences and preferences with digital radiography, quality control procedures, patient dose, advantages and disadvantages of digital radiography were sought. The information collected was based on self-reporting by the participants. The study is exploratory in nature and descriptive statistics were generated from the collected data using Microsoft Excel 2007 and StatsDirect software. Results: Sixty-three out of 205 (31%) radiographers from all the four radiology centers responded to the circulated questionnaire. Only 15% (8) of the qualified radiographers had 4 or more years of experience with digital radiography compared to 68% (36) for the same amount of experience with screen-film radiography. Sixty-one percent (38) of the participants had been exposed to digital radiography during their lectures while at university. A small proportion, 16% (10) of the respondents underwent formal training in quality control procedures on the digital X-ray units they were using. Slightly more than half (55%) of the participants felt it was easier for them to retake an image in digital radiography than in screen film radiography. Conclusion: The results of this survey showed that the participants are familiar with digital radiography and have embraced this relatively new technology as shown by the fact that they can identify both its advantages and disadvantages as applied to clinical practice. However, there are minimal quality control procedures specific to digital

  10. Productivity improvements with a direct digital radiography system integrated with PACS

    Science.gov (United States)

    Jeromin, Lothar S.; Lee, Denny L. Y.; Palecki, Eugene F.; Wolff, David P.

    1996-05-01

    The productivity-improving features of a direct digital radiography system for projection radiography are introduced and the integration of the system with PACS is discussed. A flat panel digital array, an array controller, and a system controller with video monitor and standard interface to a local or wide area communications network are the main components of the direct digital radiography system of which prototypes have been built and tested in laboratory settings. When used in radiology room for projection radiography, the digital array converts x-ray photons into digital image data and makes the data available immediately for display on a video monitor for the technologist's review. Upon the technologist's acceptance of the image, an industry-standard network allows the transmission of the image to a workstation where additional image processing can be performed and where the image can be viewed on a high resolution display by the radiologist. If so desired, the image may be routed to a laser printer, digital mass storage medium, or to a PACS communication interface. By connecting the direct digital radiography system with a PACS network, radiographs may be shared electronically like images of other digital modalities. In this scenario, productivity improvements would come mainly from shorter patient exams as a result of the immediate availability of the review images, wider exposure latitude and ease of handling of the digital array, and from the electronic transport, storage and retrieval of image files and patient data in a PACS environment.

  11. Basic science in digital imaging: digital dynamic radiography, multimedia, and their potential uses for orthopaedics and arthroscopic surgery.

    Science.gov (United States)

    Pavlovich, Rafael Iñigo; Vazquez-Vela, Gonzalo; Pardinas, Javier Lozano; Bustos Villarreal, Jose Maria; Rico, Eduardo Carriedo; de la Mora Behar, Gustavo

    2002-01-01

    In this article, we discuss the different types of up-to-date tools available to understand multimedia and its applications, imaging manipulation, digital video, and new approaches to surgical planning, digital dynamic radiography, and patient education aided by digital technology.

  12. Application of digital radiography for measuring in clinical dental practice

    Directory of Open Access Journals (Sweden)

    Ilić Dragan V.

    2015-01-01

    Full Text Available Introduction. The recent literature data points out a rising application of digital radiography - radiovisiography (RVG - in dental clinical practice. Objective. The aim of this study was to apply and compare RVG with the conventional radiographic technique (CRDG in terms of accuracy in linear measurement in dentistry. Methods. Measurements were done on the mandibular dogs teeth considering incisors crown width and height of the surrounding alveolar bone using RVG and CRDG. The control technique (CONT involved values obtained by direct gauging in dogs mouth. Each measuring was done by two examiners. Results. Considering the incisors’ crown width, there were no significant statistical difference in measurement using CRDG, RVG and CONT technique (p>0.01. Concerning the alveolar height gauging there were no significant difference in recorded values between the two radiographic techniques (p>0.01. The high level of inter-examiner agreement was observed for scoring in all techniques (CRDG, RVG and CONT. Conclusion. Although RVG did not expose more accuracy comparing to CRDG, having opulent tool service the first technique contributed more comfortable work during measuring procedures in this study.

  13. Quality control measurements for digital x-ray detectors.

    Science.gov (United States)

    Marshall, N W; Mackenzie, A; Honey, I D

    2011-02-21

    This paper describes a digital radiography (DR) quality control protocol for DR detectors from the forthcoming report from the Institute of Physics and Engineering in Medicine (IPEM). The protocol was applied to a group of six identical caesium iodide (CsI) digital x-ray detectors to assess reproducibility of methods, while four further detectors were assessed to examine the wider applicability. Twelve images with minimal spatial frequency processing are required, from which the detector response, lag, modulation transfer function (MTF), normalized noise power spectrum (NNPS) and threshold contrast-detail (c-d) detectability are calculated. The x-ray spectrum used was 70 kV and 1 mm added copper filtration, with a target detector air kerma of 2.5 µGy for the NNPS and c-d results. In order to compare detector performance with previous imaging technology, c-d data from four screen/film systems were also acquired, at a target optical density of 1.5 and an average detector air kerma of 2.56 µGy. The DR detector images were typically acquired in 20 min, with a further 45 min required for image transfer and analysis. The average spatial frequency for the 50% point of the MTF for six identical detectors was 1.29 mm(-1) ± 0.05 (3.9% coefficient of variation (cov)). The air kerma set for the six systems was 2.57 µGy ± 0.13 (5.0% cov) and the NNPS at this air kerma was 1.42 × 10(-5) mm(2) (6.5% cov). The detective quantum efficiency (DQE) measured for the six identical detectors was 0.60 at 0.5 mm(-1), with a maximum cov of 10% at 2.9 mm(-1), while the average DQE was 0.56 at 0.5 mm(-1) for three CsI detectors from three different manufacturers. Comparable c-d performance was found for these detectors (5.9% cov) with an average threshold contrast of 0.46% for 11 mm circular discs. The average threshold contrast for the S/F systems was 0.70% at 11 mm, indicating superior imaging performance for the digital systems. The protocol was found to be quick, reproducible and

  14. OPTIMIZATION OF RADIATION PROTECTION BY ELIMINATING WEEDS OUT RASTER DIGITAL RADIOGRAPHY OF THE CHEST

    Directory of Open Access Journals (Sweden)

    I. G. Kamyshanskaja

    2015-01-01

    Full Text Available An experimental study of the possibility of eliminating the raster digital radiography. On stationary digital x-ray machine produced 117 x-ray images of the test object and x-rays of the chest cavity with the gridand without him several patients-volunteers. Proven ability to eliminate grid digital radiography by digital processing of images, made without the grid that reduces dose radiation exposure of the patient more than in 3 times. «Virtual» grids enough improve the diagnostic quality of the photo to eliminate the pathology.

  15. Role of digital tomosynthesis and dual energy subtraction digital radiography in detecting pulmonary nodules

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Sarvana G. [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Garg, Mandeep Kumar, E-mail: gargmandeep01@gmail.com [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Khandelwal, Niranjan; Gupta, Pankaj [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Gupta, Dheeraj; Aggarwal, Ashutosh Nath [Department of Pulmonary Medicine, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India); Bansal, Subash Chand [Department of Radiodiagnosis and Imaging, Postgraduate Institute of Medical Education and Research (PGIMER), Sector 12, Chandigarh 160012 (India)

    2015-07-15

    Highlights: • Accuracy of digital tomosynthesis for nodule detection is substantially higher. • Improvement in diagnostic accuracy is most pronounced for nodules <10 mm. • There is five times increase in radiation dose compared to DR. - Abstract: Objective: Digital tomosynthesis (DT) and dual-energy subtraction digital radiography (DES-DR) are known to perform better than conventional radiography in the detection of pulmonary nodules. Yet the comparative diagnostic performances of DT, DES-DR and digital radiography (DR) is not known. The present study compares the diagnostic performances of DT, DES-DR and DR in detecting pulmonary nodules. Subjects and methods: The institutional Review Board approved the study and informed written consent was obtained. Fifty-five patients (30 with pulmonary nodules, 25 with non-nodular focal chest pathology) were included in the study. DT and DES-DR were performed within14 days of MDCT. Composite images acquired at high kVp as part of DES-DR were used as DR images. Images were analyzed for presence of nodules and calcification in nodules. Interpretations were assigned confidence levels from 1 to 5 according to Five-Point rating scale. Areas under the receiver operating characteristic curves were compared using Z test. Results: A total of 110 (88 non-calcified, 22 calcified) nodules were identified on MDCT. For detection of nodules, DR showed cumulative sensitivity and specificity of 25.45% and 67.97%, respectively. DT showed a cumulative sensitivity and specificity of 60.9% and 85.07%, respectively. The performance was significantly better than DR (p < 0.003). DES-DR showed sensitivity and specificity of 27.75% and 82.64%, not statistically different from those of DR (p—0.92). In detection of calcification, there was no statistically significant difference between DT, DES-DR and DR. Conclusions: DT performs significantly better than DES-DR and DR at the cost of moderate increase in radiation dose.

  16. Dose audit for patients undergoing two common radiography examinations with digital radiology systems.

    Science.gov (United States)

    İnal, Tolga; Ataç, Gökçe

    2014-01-01

    We aimed to determine the radiation doses delivered to patients undergoing general examinations using computed or digital radiography systems in Turkey. Radiographs of 20 patients undergoing posteroanterior chest X-ray and of 20 patients undergoing anteroposterior kidney-ureter-bladder radiography were evaluated in five X-ray rooms at four local hospitals in the Ankara region. Currently, almost all radiology departments in Turkey have switched from conventional radiography systems to computed radiography or digital radiography systems. Patient dose was measured for both systems. The results were compared with published diagnostic reference levels (DRLs) from the European Union and International Atomic Energy Agency. The average entrance surface doses (ESDs) for chest examinations exceeded established international DRLs at two of the X-ray rooms in a hospital with computed radiography. All of the other ESD measurements were approximately equal to or below the DRLs for both examinations in all of the remaining hospitals. Improper adjustment of the exposure parameters, uncalibrated automatic exposure control systems, and failure of the technologists to choose exposure parameters properly were problems we noticed during the study. This study is an initial attempt at establishing local DRL values for digital radiography systems, and will provide a benchmark so that the authorities can establish reference dose levels for diagnostic radiology in Turkey.

  17. A new clinical unit for digital radiography based on a thick amorphous Selenium plate: Physical and psychophysical characterization

    Energy Technology Data Exchange (ETDEWEB)

    Rivetti, Stefano; Lanconelli, Nico; Bertolini, Marco; Acchiappati, Domenico [Alma Mater Studiorum, Physics Department, University of Bologna, 40127 Bologna, Italy and S.C. di Fisica Sanitaria ' ' Azienda USL di Modena' ' 41100 Modena (Italy); Alma Mater Studiorum, Physics Department, University of Bologna, 40127 Bologna (Italy); Arcispedale Santa Maria Nuova, 42123 Reggio Emilia (Italy); S.C. di Fisica Sanitaria ' ' Azienda USL di Modena' ' 41100 Modena (Italy)

    2011-08-15

    Purpose: Here, we present a physical and psychophysical characterization of a new clinical unit (named AcSelerate) for digital radiography based on a thick a-Se layer. We also compared images acquired with and without a software filter (named CRF) developed for reducing sharpness and noise of the images and making them similar to images coming from traditional computed radiography systems. Methods: The characterization was achieved in terms of physical figures of merit [modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE)], and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). We accomplished measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9. Results: The system shows an excellent MTF (about 50% at the Nyquist frequency). The DQE is about 55% at 0.5 lp/mm and above 20% at the Nyquist frequency and is almost independent from exposure. The contrast-detail curves are comparable to some of the best published data for other systems devoted to imaging in general radiography. The CRF filter influences both the MTF and NPS, but it does lead to very small changes on DQE. Also the visibility of CDRAD details is basically unaltered, when the filter is activated. Conclusions: As normally happens with detector based on direct conversion, the system presents an excellent MTF. The improved efficiency caused by the thick layer allows getting good noise characteristics and DQE results better (about 10% on average) than many of the computed radiography (CR) systems and comparable to those obtained by the best systems for digital radiography available on the market.

  18. Lumbar spine radiography — poor collimation practices after implementation of digital technology

    DEFF Research Database (Denmark)

    Zetterberg, Lars Gøran; Espeland, Ansgar

    2011-01-01

    Objectives: The transition from analogue to digital radiography may have reduced the motivation to perform proper collimation, as digital techniques have made it possible to mask areas irradiated outside the area of diagnostic interest (ADI). We examined the hypothesis that collimation practices ...

  19. Development of neutron detectors and neutron radiography at Bhabha Atomic Research Centre

    Indian Academy of Sciences (India)

    A M Shaikh

    2008-10-01

    Design and development of neutron detectors and R&D work in neutron radiography (NR) for non-destructive evaluation are important parts of the neutron beam and allied research programme of Solid State Physics Division (SSPD) of Bhabha Atomic Research Centre (BARC). The detectors fabricated in the division not only meet the in-house requirement of neutron spectrometers but also the need of other divisions in BARC, Department of Atomic Energy units and some universities and research institutes in India and abroad for a variety of applications. The NR facility set up by SSPD at Apsara reactor has been used for a variety of applications in nuclear, aerospace, defense and metallurgical industries. The work done in the development of neutron detectors and neutron radiography is reported in this article.

  20. Design, optimization and evaluation of a "smart" pixel sensor array for low-dose digital radiography

    Science.gov (United States)

    Wang, Kai; Liu, Xinghui; Ou, Hai; Chen, Jun

    2016-04-01

    Amorphous silicon (a-Si:H) thin-film transistors (TFTs) have been widely used to build flat-panel X-ray detectors for digital radiography (DR). As the demand for low-dose X-ray imaging grows, a detector with high signal-to-noise-ratio (SNR) pixel architecture emerges. "Smart" pixel is intended to use a dual-gate photosensitive TFT for sensing, storage, and switch. It differs from a conventional passive pixel sensor (PPS) and active pixel sensor (APS) in that all these three functions are combined into one device instead of three separate units in a pixel. Thus, it is expected to have high fill factor and high spatial resolution. In addition, it utilizes the amplification effect of the dual-gate photosensitive TFT to form a one-transistor APS that leads to a potentially high SNR. This paper addresses the design, optimization and evaluation of the smart pixel sensor and array for low-dose DR. We will design and optimize the smart pixel from the scintillator to TFT levels and validate it through optical and electrical simulation and experiments of a 4x4 sensor array.

  1. EVALUATION OF GRAY INTENSITY VALUE FOR RELIABLE DIGITIZATION OF DIGITAL RADIOGRAPHY IN DEFECT DETECTION

    Directory of Open Access Journals (Sweden)

    P.Chitra

    2011-08-01

    Full Text Available Radiography is one of the oldest NDT technique used for evaluation of weld defects in metal. Radiographic defects are classified based on the shape, location, orientation, depth, width etc. Once a radiographof a weld is taken, the radiographer examines the same for identifying the defects and quantitatively evaluating the same based on codes and specifications. In recent years digital imaging has superseded conventional imaging, which has led to a profound change in interpretation of radiographic images. A change in the Gray values of the digital image (edges indicates the flaws on the radiographic image. This paper discusses the Gray level distribution of a test piece radiograph. The test piece considered is a stainless steel metal plate on which a square hole is drilled with different area and depth. The plate is radiographed using X-ray and gamma rays (IR192.

  2. An examination of automatic exposure control regimes for two digital radiography systems.

    Science.gov (United States)

    Marshall, N W

    2009-08-07

    The influence of two methods of an automatic exposure control (AEC) setup using a simple measure of detectability is examined as a function of x-ray beam quality for a computed radiography (CR) system and for an indirect conversion digital radiography (DR) system. The regimes assessed were constant air kerma at the detector and the constant contrast noise ratio (CNR). A low scatter geometry was employed with x-ray spectra varying from 60 kV and 1 mm Cu to 125 kV and 2 mm Cu. The CNR was measured using a 2 mm thick Al square of dimension 1 cm by 1 cm. Detectability was quantified via a nominal contrast for a fixed beam quality of 70 kV and 1 mm added Cu filtration, taken from c-d curves measured using the Leeds TO20 test object, for the four x-ray spectra. In addition, objective image quality parameters including modulation transfer function (MTF), noise power spectrum (NPS) and detective quantum efficiency (DQE) were also measured for both systems at the four different x-ray spectra. It was found that the constant air kerma strategy did not maintain threshold nominal contrast (simple detectability) constant as the x-ray beam mean energy increased, for either the CR system or the DR system. For the CR detector, the threshold nominal contrast for a 1 mm disc increased by a factor of 4.4 from 3.50% to 15.4% as the tube potential was raised from 60 kV to 125 kV, while for the DR detector, the threshold nominal contrast increased by a factor of 3.4, from 2.27% to 7.67% as the tube potential increased from 60 kV to 120 kV. The constant CNR method was more successful at maintaining constant detectability for the c-d discs. The threshold nominal contrast for the 1 mm disc changed by a factor of 1.2, from 4.80% to 5.70% for the CR system, as the spectrum changed from 60 kV to 125 kV. For the indirect conversion detector, the threshold nominal contrast increased from 2.27% to 5.66% (a factor of 1.4 increase). The constant CNR strategy required an increase in air kerma by

  3. Diagnostic accuracy of direct digital radiography and conventional radiography for proximal caries detection in primary teeth: A systematic review

    Directory of Open Access Journals (Sweden)

    Sivakumar Nuvvula

    2016-01-01

    Full Text Available Objective: The present study was conducted to uncover the diagnostic accuracy of digital versus conventional radiographic methods for the detection of proximal caries in primary teeth. Methods: Two researchers independently involved in the search process to explore Medical Subject Heading terms "dental digital radiography," "dental radiography," "bitewing," "dental caries," and "primary teeth" using PubMed, Cochrane Library, Ovid SP, and SIGLE databases. Search was confined to the articles published in English language only, with time period limit January 1996 to April 2014 and a hand search was performed to retrieve additional citations. Explicit inclusion and exclusion criteria were applied to eliminate undesired studies. Critical appraisal of the retrieved articles was done using the quality rating based on Bader and co-workers criteria. Results: A total of 129 articles were retrieved, among which 4 articles were included. All the four studies included were in vitro, of which two studies attained a high-quality score, whereas the other two attained average, and low scores based on Bader et al.′s criteria. Conclusions: A big lacuna exists in the literature, regarding the evaluation of radiographic systems in primary teeth, suggesting an immediate need for well conducted in vivo studies. The quality of available evidence can be regarded as fair but cannot be suggested to set a baseline, indicating a need to perform high-quality studies in a randomized sample to find out the accuracy of digital and conventional radiographs.

  4. Tests of a new CCD-camera based neutron radiography detector system at the reactor stations in Munich and Vienna

    Energy Technology Data Exchange (ETDEWEB)

    Lehmann, E.; Pleinert, H. [Paul Scherrer Inst. (PSI), Villigen (Switzerland); Schillinger, B. [Technische Univ. Muenchen (Germany); Koerner, S. [Atominstitut der Oesterreichischen Universitaeten, Vienna (Austria)

    1997-09-01

    The performance of the new neutron radiography detector designed at PSI with a cooled high sensitive CCD-camera was investigated under real neutronic conditions at three beam ports of two reactor stations. Different converter screens were applied for which the sensitivity and the modulation transfer function (MTF) could be obtained. The results are very encouraging concerning the utilization of this detector system as standard tool at the radiography stations at the spallation source SINQ. (author) 3 figs., 5 refs.

  5. Digital detectors for electron microscopy

    CERN Document Server

    Faruqi, A R

    2002-01-01

    Film has traditionally been used for recording images in transmission electron microscopes but there is an essential need for computer-interfaced electronic detectors. Cooled-CCD detectors, developed over the past few years, though not ideal, are increasingly used as the preferred detection system in a number of applications. We describe briefly the design of CCD-based detectors, along with their main properties, which have been used in electron crystallography. A newer detector design with a much bigger sensitive area, incorporating a 2x2 tiled array of CCDs with tapered fibre optics will overcome some of the limitations of existing CCD detectors. We also describe some preliminary results for 8 keV imaging, from (direct detection) silicon hybrid pixel detectors, which offer advantages over CCDs in terms of better spatial resolution, faster readout with minimal noise.

  6. Multi-energy radiography on the basis of "scintillator-photodiode" detectors

    CERN Document Server

    Naydenov, S V; Grinyov, B V; Lisetskaya, E K; Kozin, D N; Opolonin, A D

    2003-01-01

    For reconstruction of the spatial structure and thicknesses of complex objects and materials, it is proposed to use multi-radiography with detection of X-ray or gamma-radiation by combined detector arrays of scintillator-photodiode type. Experimental studies have been carried out of the energy dependence of sensitivity of dual-energy inspection systems based on scintillators $ZnSe(Te)$ and $CsI(Tl)$.

  7. Large area x-ray detectors for cargo radiography

    Science.gov (United States)

    Bueno, C.; Albagli, D.; Bendahan, J.; Castleberry, D.; Gordon, C.; Hopkins, F.; Ross, W.

    2007-04-01

    Large area x-ray detectors based on phosphors coupled to flat panel amorphous silicon diode technology offer significant advances for cargo radiologic imaging. Flat panel area detectors provide large object coverage offering high throughput inspections to meet the high flow rate of container commerce. These detectors provide excellent spatial resolution when needed, and enhanced SNR through low noise electronics. If the resolution is reduced through pixel binning, further advances in SNR are achievable. Extended exposure imaging and frame averaging enables improved x-ray penetration of ultra-thick objects, or "select-your-own" contrast sensitivity at a rate many times faster than LDAs. The areal coverage of flat panel technology provides inherent volumetric imaging with the appropriate scanning methods. Flat panel area detectors have flexible designs in terms of electronic control, scintillator selection, pixel pitch, and frame rates. Their cost is becoming more competitive as production ramps up for the healthcare, nondestructive testing (NDT), and homeland protection industries. Typically used medical and industrial polycrystalline phosphor materials such as Gd2O2S:Tb (GOS) can be applied to megavolt applications if the phosphor layer is sufficiently thick to enhance x-ray absorption, and if a metal radiator is used to augment the quantum detection efficiency and reduce x-ray scatter. Phosphor layers ranging from 0.2-mm to 1-mm can be "sandwiched" between amorphous silicon flat panel diode arrays and metal radiators. Metal plates consisting of W, Pb or Cu, with thicknesses ranging from 0.25-mm to well over 1-mm can be used by covering the entire area of the phosphor plate. In some combinations of high density metal and phosphor layers, the metal plate provides an intensification of 25% in signal due to electron emission from the plate and subsequent excitation within the phosphor material. This further improves the SNR of the system.

  8. Comparison of conventional panoramic radiography and panoramic digital subtraction radiography in detection of simulated lesions of mandibular condyle

    Directory of Open Access Journals (Sweden)

    Panjnoush M.

    2008-12-01

    Full Text Available "n  "nBackground and Aim: Digital subtraction Radiography (DSR is a method of accurate assessing condylar head changes. several studies have been carried out in applying DSR in dentistry, however there is a few number of studies in efficacy of DSR method in assesment of condylar head changes, The aim of this study was to compare panoramic radiography and DSR detecting simulated lesions of the mandibular condyl. "nMaterials and Methods: this was a process reaserch study, in which two dry human skulls with no obvious temporomandibular joint pathology were used. Osteophytic lesions were simulated using three sizes of bone chips that were placed on the medial portion of anterior and superolateral aspects of the condyle. Osteolytic lesions were simulated making 1 and 2 mm holes using round burr in the central portion of anterior aspect and Lateral pole of the condyle. Panoramic radiographs were prepared with and without the lesions in place. These paired radiographs were digitized and digital- subtraction images of the original panoramic images were obtained. Eight observers evaluated 155 images of each modality for the presence or absence and the type of simulated lesions of the mandibular condyle. Sensitivity, specificity, reliability and measure of agreement were analyzed using kappa test and crossed tables and qualitative variables were assess by chi-square and fisher's Exact test. "nResults: Specificity of panoramic and DSR methods were 15.4% and 66.7% respectively. Sensitivity of panoramic and DSR methods were 61.1% and 80.6% for osteophytic lesions and 37.5% and 83.3% for Osteolytic lesions. The percentage of correct decisions made in DSR method was significantly more than conventional panoramic method (82.6% vs 41.9% (p<0.0001. "nConclusion: Based on the results of this study digital subtraction technique was significantly more accurate than the panoramic radiographs in detection of simulated lesions of the mandibular condyle.

  9. Searching early bone metastasis on plain radiography by using digital imaging processing

    Energy Technology Data Exchange (ETDEWEB)

    Jaramillo-Nunez, A.; Perez-Meza, M. [Instituto Nacional de Astrofisica, Optica y Electronica, Apdo. Postal 51 y 216, Pue. (Mexico); Universidad de la Sierra Sur, C. P. 70800, Miahuatlan, Oax. (Mexico)

    2012-10-23

    Some authors mention that it is not possible to detect early bone metastasis on plain radiography. In this work we use digital imaging processing to analyze three radiographs taken from a patient with bone metastasis discomfort on the right shoulder. The time period among the first and second radiography was approximately one month and between the first and the third one year. This procedure is a first approach in order to know if in this particular case it was possible to detect an early bone metastasis. The obtained results suggest that by carrying out a digital processing is possible to detect the metastasis since the radiography contains the information although visually it is not possible to observe it.

  10. The scope of detector Medipix2 in micro-radiography of biological samples

    Energy Technology Data Exchange (ETDEWEB)

    Dammer, J., E-mail: jiri.dammer@utef.cvut.cz [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Weyda, F. [Biology Centre of the Academy of Sciences of the Czech Republic, Institute of Entomology, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Faculty of Science, University of South Bohemia, Branisovska 31, CZ-37005 Ceske Budejovice (Czech Republic); Jakubek, J. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic); Skrabal, P. [Faculty of Biomedical Engineering, Czech Technical University in Prague, Nam. Sitna 3105, CZ-272 01 Kladno (Czech Republic); Sopko, V.; Vavrik, D. [Institute of Experimental and Applied Physics, Czech Technical University in Prague, Horska 3a/22, CZ-12800 Prague 2 (Czech Republic)

    2011-05-15

    We present our experimental setup devoted to high resolution X-ray micro-radiography that is suitable for imaging of small biological samples. The photon source is a FeinFocus micro-focus X-ray tube. The single photon counting pixel device Medipix2 serves as imaging area. Recently used imaging detectors as radiography films or scintillator detectors, cannot visualize required information about inner structure of scanned sample. Detectors Medipix2 do not suffer from so-called dark current noise and work in unlimited dynamic range. These features of detectors confer high quality and high contrast of final images. The radiographic imaging with detectors Medipix2 represents non-invasive and non-destructive method of investigation. Hereby, we demonstrate results of micro-radiographic study of internal structures of tiny biological samples. In addition to morphological and anatomical studies, we would like to present preliminary study of dynamic processes inside of organisms using micro-radiographic video-capturing.

  11. Role of digital tomosynthesis and dual energy subtraction digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Madhurima, E-mail: madhurimashrm88@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Sandhu, Manavjit Singh, E-mail: manavjitsandhu@yahoo.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gorsi, Ujjwal, E-mail: ujjwalgorsi@gmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India); Gupta, Dheeraj, E-mail: dheeraj1910@gmail.com [Department of Pulmonary Medicine, PGIMER, Chandigarh 160012 (India); Khandelwal, Niranjan, E-mail: khandelwaln@hotmail.com [Department of Radiodiagnosis and Imaging, PGIMER, Chandigarh 160012 (India)

    2015-09-15

    Highlights: • Digital tomosynthesis and dual energy subtraction digital radiography are modifications of digital radiography. • These modalities perform better than digital radiography in detection of parenchymal lesions in active pulmonary tuberculosis. • Digital tomosynthesis has a sensitivity of 100% in detection of cavities. • Centrilobular nodules seen on CT in active pulmonary tuberculosis, were also demonstrated on digital tomosynthesis in our study. • Digital tomosynthesis can be used for diagnosis and follow up of patients in pulmonary tuberculosis, thereby reducing the number of CT examinations. - Abstract: Objective: To assess the role of digital tomosynthesis (DTS) and dual energy subtraction digital radiography (DES-DR) in detection of parenchymal lesions in active pulmonary tuberculosis (TB) and to compare them with digital radiography (DR). Materials and methods: This prospective study was approved by our institutional review committee. DTS and DES-DR were performed in 62 patients with active pulmonary TB within one week of multidetector computed tomography (MDCT) study. Findings of active pulmonary TB, that is consolidation, cavitation and nodules were noted on digital radiography (DR), DTS and DES-DR in all patients. Sensitivity, specificity, positive and negative predictive values of all 3 modalities was calculated with MDCT as reference standard. In addition presence of centrilobular nodules was also noted on DTS. Results: Our study comprised of 62 patients (33 males, 29 females with age range 18–82 years). Sensitivity and specificity of DTS for detection of nodules and cavitation was better than DR and DES-DR. Sensitivity and specificity of DTS for detection of consolidation was comparable to DR and DES-DR. DES-DR performed better than DR in detection of nodules and cavitation. DTS was also able to detect centrilobular nodules with sensitivity and specificity of 57.4% and 86.5% respectively. Conclusion: DTS and DES-DR perform better

  12. Conventional Versus Digital Radiography in Detecting Root Canal Type in Maxillary Premolars: An in Vitro Study

    Directory of Open Access Journals (Sweden)

    Mahkameh Moshfeghi

    2013-01-01

    Full Text Available Objective: Successful endodontic therapy depends on adequate mechanical and chemical debridement of the canal which requires knowledge of the canal morphology. Conventional radiography has been used to evaluate the canal type; however, direct digital radiography has recently been practiced for this purpose due to the shortcomings of conventional radiography. The aim of the present study was to compare the accuracy of digital and conventional radiography taken at 0° and 30° angles in the diagnosis of the canal type of extracted maxillary premolars.Materials and Methods: This diagnostic study was performed on 90 extracted maxillary premolars. Conventional and digital radiographies were taken of all teeth at 0° and 30° horizontal angles. The images were assessed by an oral and maxillofacial radiologist. The clearing technique was used as the gold standard. The canal type was determined using Weine classification. The agreement between each one of the 4 radiographic modalities and gold standard was determined by kappa statistics.Results: The kappa values for the agreement of parallel conventional, 30° conventional, parallel digital and 30° digital modalities with the clearing technique were 0.059, 0.215, 0.043 and 0.391, respectively. Parallel modalities were unable to determine the tooth canal type. Radiographic images taken at 30° significantly determined the canal type, although only a poor level of agreement was noted between the two modalities and the clearing technique.Conclusion: All modalities had limited value to determine the root canal type in maxillary premolars. However, direct digital imaging taken at 30° angle showed the highest accuracy for canal type assessment.

  13. Reproducibility between conventional and digital periapical radiography for bone height measurement

    OpenAIRE

    Miguel Simancas-Pallares; Jorge Andrés Rubio-Romero; Edgar Cortés-Reyes

    2015-01-01

    Background. Several diagnostic aids are available for bone height measurement. Digital and conventional radiographs are the two ones most used in Dentistry. Few studies accounting for accuracy and precision have been conducted to compare these methods. Objective. The aim of this study was to estimate reproducibility between conventional and digital periapical radiography in bone height measurement in patients with chronic periodontitis. Methods. a consistency diagnostic test study was perform...

  14. Digital Radiography for Determination of Primary Tooth Length: In Vivo and Ex Vivo Studies

    Directory of Open Access Journals (Sweden)

    Maria D. Basso

    2015-01-01

    Full Text Available Background. Methods for determining the root canal length of the primary tooth should yield accurate and reproducible results. In vitro studies show some limitations, which do not allow their findings to be directly transferred to a clinical situation. Aim. To compare the accuracy of radiographic tooth length obtained from in vivo digital radiograph with that obtained from ex vivo digital radiograph. Method. Direct digital radiographs of 20 upper primary incisors were performed in teeth (2/3 radicular resorption that were radiographed by an intraoral sensor, according to the long-cone technique. Teeth were extracted, measured, and mounted in a resin block, and then radiographic template was used to standardise the sensor-target distance (30 cm. The apparent tooth length (APTL was obtained from the computer screen by means of an electronic ruler accompanying the digital radiography software (CDR 2.0, whereas the actual tooth length (ACTL was obtained by means of a digital calliper following extraction. Data were compared to the ACTL by variance analysis and Pearson’s correlation test. Results. The values for APTL obtained from in vivo radiography were slightly underestimated, whereas those values obtained from ex vivo were slightly overestimated. No significance was observed (P≤0.48 between APTL and ACTL. Conclusion. The length of primary teeth estimated by in vivo and ex vivo comparisons using digital radiography was found to be similar to the actual tooth length.

  15. Investigation of measurement accuracy of factors used for detective quantum efficiency measurement in digital radiography.

    Science.gov (United States)

    Kunitomo, Hiroshi; Koyama, Shuji; Higashide, Ryo; Ichikawa, Katsuhiro; Hattori, Masumi; Okada, Yoko; Hayashi, Norio; Sawada, Michito

    2014-07-01

    In the detective quantum efficiency (DQE) evaluation of detectors for digital radiography (DR) systems, physical image quality indices such as modulation transfer function (MTF) and normalized noise power spectrum (NNPS) need to be accurately measured to obtain highly accurate DQE evaluations. However, there is a risk of errors in these measurements. In this study, we focused on error factors that should be considered in measurements using clinical DR systems. We compared the incident photon numbers indicated in IEC 62220-1 with those estimated using a Monte Carlo simulation based on X-ray energy spectra measured employing four DR systems. For NNPS, influences of X-ray intensity non-uniformity, tube voltage and aluminum purity were investigated. The effects of geometric magnifications on MTF accuracy were also examined using a tungsten edge plate at distances of 50, 100 and 150 mm from the detector surface at a source-image receptor distance of 2000 mm. The photon numbers in IEC 62220-1 coincided with our estimates of values, with error rates below 2.5%. Tube voltage errors of approximately ±5 kV caused NNPS errors of within 1.0%. The X-ray intensity non-uniformity caused NNPS errors of up to 2.0% at the anode side. Aluminum purity did not affect the measurement accuracy. The maximum MTF reductions caused by geometric magnifications were 3.67% for 1.0-mm X-ray focus and 1.83% for 0.6-mm X-ray focus.

  16. Nuclear Emulsion Film Detectors for Proton Radiography: Design and Test of the First Prototype

    CERN Document Server

    Braccini, S; Kreslo, I; Moser, U; Pistillo, C; Scampoli, P; Studer, S

    2010-01-01

    Proton therapy is nowadays becoming a wide spread clinical practice in cancer therapy and sophisticated treatment planning systems are routinely used to exploit at best the ballistic properties of charged particles. The information on the quality of the beams and the range of the protons is a key issue for the optimization of the treatment. For this purpose, proton radiography can be used in proton therapy to obtain direct information on the range of the protons, on the average density of the tissues for treatment planning optimization and to perform imaging with negligible dose to the patient. We propose an innovative method based on nuclear emulsion film detectors for proton radiography, a technique in which images are obtained by measuring the position and the residual range of protons passing through the patient's body. Nuclear emulsion films interleaved with tissue equivalent absorbers can be fruitfully used to reconstruct proton tracks with very high precision. The first prototype of a nuclear emulsion ...

  17. The pilot experimental study of 14 MeV fast neutron digital radiography

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    14 MeV Fast neutrons has good penetrability and the 14 MeV fast neutron radiography can meet the need of Non-Destructive Test of the structure and lacuna of heavy-massive sample, whose shell is made of heavy metal and in which there are some hydrogen materials, and the study of fast neutron digital radiography just begins in China. By the use of a D-T accelerator, a digital imaging system made up of a fast neutron scintillation screen made of ZnS(Ag) and polypropylene, lens and a scientific grade CCD, the experimental study of fast neutron radiography has been done between 4.3×1010-6.8×1010 n/s of neutron yield. Some 14 MeV fast neutron digital radiographs have been gotten. According to experimental radiographs and their data, the performance of the fast neutron scintillation screen and the basic characters of 14 MeV fast neutron radiography are analyzed, and it is helpful for the further research.

  18. The pilot experimental study of 14 MeV fast neutron digital radiography

    Institute of Scientific and Technical Information of China (English)

    TANG Bin; ZHOU ChangGen; HUO HeYong; WU Yang; LIU Bin; LOU BenChao; SUN Yong

    2009-01-01

    14 MeV Fast neutrons has good penetrability and the 14 MeV fast neutron radiography can meet the need of Non-Destructive Test of the structure and lacuna of heavy-massive sample,whose shell is made of heavy metal and in which there are some hydrogen materials,and the study of fast neutron digital radiography just begins in China.By the use of a D-T accelerator,a digital imaging system made up of a fast neutron scintillation screen made of ZnS(Ag) and polypropylene,lens and a scientific grade CCD,the experimental study of fast neutron radiography has been done between 4.3×1010-6.8×1010 n/s of neutron yield.Some 14 MeV fast neutron digital radiographs have been gotten.According to ex-perimental radiographs and their data,the performance of the fast neutron scintillation screen and the basic characters of 14 MeV fast neutron radiography are analyzed,and it is helpful for the further re-search.

  19. Characterization of a clinical unit for digital radiography based on irradiation side sampling technology

    Energy Technology Data Exchange (ETDEWEB)

    Rivetti, Stefano [Fisica Medica, Ospedale di Sassuolo S.p.A., 41049 Sassuolo (Italy); Lanconelli, Nico [Alma Mater Studiorum, Physics Department, University of Bologna, 40127 Bologna (Italy); Bertolini, Marco; Nitrosi, Andrea [Medical Physics Unit, Azienda Ospedaliera ASMN, Istituto di Ricovero e Cura a Carattere Scientifico, 42123 Reggio Emilia (Italy); Burani, Aldo [Ospedale di Sassuolo S.p.A., 41049 Sassuolo (Italy)

    2013-10-15

    Purpose: A characterization of a clinical unit for digital radiography (FUJIFILM FDR D-EVO) is presented. This system is based on the irradiation side sampling (ISS) technology and can be equipped with two different scintillators: one traditional gadolinium-oxysulphide phosphor (GOS) and a needle structured cesium iodide (CsI) phosphor panel.Methods: The characterization was achieved in terms of response curve, modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). For both scintillation screens the authors accomplished the measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9.Results: At the Nyquist frequency (3.33 lp/mm) the MTF is about 35% and 25% for CsI and GOS detectors, respectively. The CsI scintillator has better noise properties than the GOS screen in almost all the conditions. This is particularly true for low-energy beams, where the noise for the GOS system can go up to a factor 2 greater than that found for CsI. The DQE of the CsI detector reaches a peak of 60%, 60%, 58%, and 50% for the RQA3, RQA5, RQA7, and RQA9 beams, respectively, whereas for the GOS screen the maximum DQE is 40%, 44%, 44%, and 35%. The contrast-detail analysis confirms that in the majority of cases the CsI scintillator is able to provide improved outcomes to those obtained with the GOS screen.Conclusions: The limited diffusion of light produced by the ISS reading makes possible the achievement of very good spatial resolution. In fact, the MTF of the unit with the CsI panel is only slightly lower to that achieved with direct conversion detectors. The combination of very good spatial resolution, together with the good noise properties reached with the CsI screen, allows achieving DQE on average about 1.5 times greater than that obtained with GOS. In fact, the DQE of unit equipped with CsI is comparable to the best

  20. Comparison of the Absorbed Dose of Target Organs between Conventional and Digital Panoramic Radiography

    Directory of Open Access Journals (Sweden)

    Zohre Reyhani

    2016-09-01

    Full Text Available The purpose of this study was to measure and compare target organ’s exposure by direct digital and conventional panoramic radiography. Dose measurements were carried out on a RANDO phantom, which TLDs were placed into 5 target area: thyroid gland, left and right submandibular and parotid salivary glands. Panoramic radiographs were taken with two conventional (CRANEX Tome, Soredex, Tusula Finland and direct digital devices (CRANEX D, Soredex, Tusula Finland.In total, the phantom was irradiated 30 times in the two systems. The TLDs were then coded and analyzed. T-test of statistical analysis was used to find the correlation. We found statistically significant reduction in absorbed dose of target organs in digital panoramic radiography(P<0.01. The highest absorbed dose was for submandibular gland and the lowest was for thyroid gland. We concluded that can reduce absorbed dose in vital organs.

  1. Digital radiography can reduce scoliosis x-ray exposure

    Energy Technology Data Exchange (ETDEWEB)

    Kling, T.F. Jr.; Cohen, M.J.; Lindseth, R.E.; De Rosa, G.P. (Indiana Univ. School of Medicine, Indianapolis (USA))

    1990-09-01

    Digital radiology is a new computerized system of acquiring x-rays in a digital (electronic) format. It possesses a greatly expanded dose response curve that allows a very broad range of x-ray dose to produce a diagnostic image. Potential advantages include significantly reduced radiation exposure without loss of image quality, acquisition of images of constant density irrespective of under or over exposure, and reduced repeat rates for unsatisfactory films. The authors prospectively studied 30 adolescents with scoliosis who had both conventional (full dose) and digital (full, one-half, or one-third dose) x-rays. They found digital made AP and lateral image with all anatomic areas clearly depicted at full and one-half dose. Digital laterals were better at full dose and equal to conventional at one-half dose. Cobb angles were easily measured on all one-third dose AP and on 8 of 10 one-third dose digital laterals. Digital clearly depicted the Risser sign at one-half and one-third dose and the repeat rate was nil in this study, indicating digital compensates well for exposure errors. The study indicates that digital does allow radiation dose to be reduced by at least one-half in scoliosis patients and that it does have improved image quality with good contrast over a wide range of x-ray exposure.

  2. Lumbar spine radiography — poor collimation practices after implementation of digital technology

    Science.gov (United States)

    Zetterberg, L G; Espeland, A

    2011-01-01

    Objectives The transition from analogue to digital radiography may have reduced the motivation to perform proper collimation, as digital techniques have made it possible to mask areas irradiated outside the area of diagnostic interest (ADI). We examined the hypothesis that collimation practices have deteriorated since digitalisation. Methods After defining the ADI, we compared the proportion of the irradiated field outside the ADI in 86 digital and 86 analogue frontal lumbar spine radiographs using the Mann–Whitney test. 50 digital images and 50 analogue images were from a Norwegian hospital and the remainder from a Danish hospital. Consecutive digital images were compared with analogue images (from the hospitals' archives) produced in the 4 years prior to digitalisation. Both hospitals' standard radiographic procedures remained unchanged during the study. For digital images, the irradiated field was assessed using non-masked raw-data images. Results The proportion of the irradiated field outside the ADI was larger in digital than in analogue images (mean 61.7% vs 42.4%, pdigital than in analogue images (791 cm2 vs 541 cm2). Conclusion Following the implementation of digital radiography, considerably larger areas were irradiated. This causes unnecessarily high radiation doses to patients. PMID:21606070

  3. Proximal caries detection using digital subtraction radiography in the artificial caries activity model

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Hoon; Lee, Gi Ja; Choi, Sam Jin; Park, Young Ho; Kim, Kyung Soo; Jin, Hyun Seok; Hong, Kyung Won; Oh, Berm Seok; Park, Hun Kuk [Department of Biomedical Engineering, School of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Choi, Yong Suk; Hwang, Eui Hwan [Department of Oral and Maxillofacial Radiology, Institute of Oral Biology, School of Dentistry, Kyung Hee University, Seoul (Korea, Republic of)

    2009-03-15

    The purpose of the experiment was to evaluating the diagnostic ability of dental caries detection using digital subtraction in the artificial caries activity model. Digital radiographs of five teeth with 8 proximal surfaces were obtained by CCD sensor (Kodak RVG 6100 using a size no.2). The digital radiographic images and subtraction images from artificial proximal caries were examined and interpreted. In this study, we proposed novel caries detection method which could diagnose the dental proximal caries from single digital radiographic image. In artificial caries activity model, the range of lesional depth was 572-1,374 {mu}m and the range of lesional area was 36.95-138.52 mm{sup 2}. The lesional depth and the area were significantly increased with demineralization time (p<0.001). Furthermore, the proximal caries detection using digital subtraction radiography showed high detection rate compared to the proximal caries examination using simple digital radiograph. The results demonstrated that the digital subtraction radiography from single radiographic image of artificial caries was highly efficient in the detection of dental caries compared to the data from simple digital radiograph.

  4. Dual-Energy Subtraction Imaging for Diagnosing Vocal Cord Paralysis with Flat Panel Detector Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Machida, Haruhiko; Yoda, Keiko; Arai, Yasuko [Tokyo Women' s Medical University Medical Center East, Tokyo (Japan)] (and others)

    2010-06-15

    To investigate the clinical feasibility of dual energy subtraction (DES) imaging to improve the delineation of the vocal cord and diagnostic accuracy of vocal cord paralysis as compared with the anterior-posterior view of flat panel detector (FPD) neck radiography. For 122 consecutive patients who underwent both a flexible laryngoscopy and conventional/DES FPD radiography, three blinded readers retrospectively graded the radiographs during phonation and inspiration on a scale of 1 (poor) to 5 (excellent) for the delineation of the vocal cord, and in consensus, reviewed the diagnostic accuracy of vocal cord paralysis employing the laryngoscopy as the reference. We compared vocal cord delineation scores and accuracy of vocal cord paralysis diagnosis by both conventional and DES techniques using ({kappa}statistics and assessing the area under the receiver operating characteristic curve (AUC). Vocal cord delineation scores by DES (mean, 4.2 {+-} 0.4) were significantly higher than those by conventional imaging (mean, 3.3 {+-} 0.5) (p < 0.0001). Sensitivity for diagnosing vocal cord paralysis by the conventional technique was 25%, whereas the specificity was 94%. Sensitivity by DES was 75%, whereas the specificity was 96%. The diagnostic accuracy by DES was significantly superior (({kappa}= 0.60, AUC = 0.909) to that by conventional technique ({kappa}= 0.18, AUC = 0.852) (p = 0.038). Dual energy subtraction is a superior method compared to the conventional FPD radiography for delineating the vocal cord and accurately diagnosing vocal cord paralysis.

  5. [Digital panoramic radiography in patients with rigid internal fixations devices after maxillofacial surgery].

    Science.gov (United States)

    Nessi, R; Ottolina, P; Lazzerini, F; Giannì, A B

    1998-01-01

    Digital techniques have found promising applications in dental radiology in the recent past, namely with radiovisiography and digital panoramic radiography. These images present some features making them particularly interesting for alveolar bone studies. Digital panoramic radiography with light-emitting phosphors was performed on 16 patients during postoperative follow-up. The patients were previously submitted to multiple maxillofacial osteosynthesis with rigid internal fixation devices (32 miniplates, 12 microplates, 14 screws). Digital images were always observed and printed with analogic-like and Xeroradiographic-like post-processing. Digital panoramic radiographs yielded clear and effective images of the maxillary and mandibular arches and of surgical osteosynthesis, as demonstrated by a retrospective evaluation performed by three independent observers on a blind basis (score 3: 60.42%), with no major interobserver differences (p = .7286). Xeroradiographic-like images were the most effective in depicting bone structures and osteosynthesis materials, thanks to their better detailing and typically lower overall contrast. Among the drawbacks of the digital technique, reduced cassette size may prevent the full view of the mandibular arch from the symphysis to both condylar regions. The edge effect, which is typical of Xeroradiographic images, may mask useful details within the trabecular bone close to metal implants. This effect was present in some of our cases, but it was seldom disturbing according to our retrospective evaluation (score 3: 53.40%), with good interobserver agreement (p = .1117). Digital panoramic radiography proves to be a useful tool to study metal implants after maxillofacial surgery as well as alveolar bone structure. The digital technique markedly reduces the radiation dose to the patient, which is very important for an X-ray examination that must be repeated several times, often in young subjects.

  6. Endodontic radiography: who is reading the digital radiograph?

    Science.gov (United States)

    Tewary, Shalini; Luzzo, Joseph; Hartwell, Gary

    2011-07-01

    Digital radiographic imaging systems have undergone tremendous improvements since their introduction. Advantages of digital radiographs over conventional films include lower radiation doses compared with conventional films, instantaneous images, archiving and sharing images easily, and manipulation of several radiographic properties that might help in diagnosis. A total of 6 observers including 2 endodontic residents, 3 endodontists, and 1 oral radiologist evaluated 150 molar digital periapical radiographs to determine which of the following conditions existed: normal periapical tissue, widened periodontal ligament, or presence of periapical radiolucency. The evaluators had full control over the radiograph's parameters of the Planmeca Dimaxis software program. All images were viewed on the same computer monitor with ideal vie-wing conditions. The same 6 observers evaluated the same 150 digital images 3 months later. The data were analyzed to determine how well the evaluators agreed with each other (interobserver agreement) for 2 rounds of observations and with themselves (intraobserver agreement). Fleiss kappa statistical analysis was used to measure the level of agreement among multiple raters. The overall Fleiss kappa value for interobserver agreement for the first round of interpretation was 0.34 (P digital radiographs are used. The factors that appeared to have the most impact were the years of experience of the examiner and familiarity of the operator with a given digital system. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  7. [A study on image processing of digital radiography and measure of material micro-density directly].

    Science.gov (United States)

    Xia, Ping; Xu, Guang-Ming; Yin, Song; Liu, Sheng-Quan; Xu, Lian-Yuan

    2008-05-01

    Due to the high influents of the device itself and the surrounding environment, the background brightness of the digital radiography image is uniform and the image shows big noise. Therefore, in order to identify digital radiography images precisely, a further image processing is necessary. In this study, adaptive filtering, histogram equalization techniques and difference image methods were used for image processing and the results show that these techniques were useful to denoise, to intensify brightness and to rectify the background. In order to verify the feasibility of these techniques, poplar wood samples of heterogeneous material were used as experimental materials and Micro-density was measured directly by applying the linear relationship between grey scale of DR image and penetrate material density and contrasted with the result of microdensitometer. The results show these techniques were feasible and even gave a more precise measurement on wood micro-density compared to microdensitometer.

  8. Noise simulation system for determining imaging conditions in digital radiography

    Science.gov (United States)

    Tanaka, R.; Ichikawa, K.; Matsubara, K.; Kawashima, H.

    2012-03-01

    Reduction of exposure dose and improvement in image quality can be expected to result from advances in the performance of imaging detectors. We propose a computerized method for determining optimized imaging conditions by use of simulated images. This study was performed to develop a prototype system for image noise and to ensure consistency between the resulting images and actual images. An RQA5 X-ray spectrum was used for determination of input-output characteristics of a flat-panel detector (FPD). The number of incident quantum to the detector per pixel (counts/pixel) was calculated according to the pixel size of the detector and the quantum number in RQA5 determined in IEC6220-1. The relationship among tube current-time product (mAs), exposure dose (C/kg) at the detector surface, the number of incident quanta (counts/pixel), and pixel values measured on the images was addressed, and a conversion function was then created. The images obtained by the FPD was converted into a map of incident quantum numbers and input into random-value generator to simulate image noise. In addition, graphic user interface was developed to observe images with changing image noise and exposure dose levels, which have trade-off relationship. Simulation images provided at different noise levels were compared with actual images obtained by the FPD system. The results indicated that image noise was simulated properly both in objective and subjective evaluation. The present system could allow us to determine necessary dose from image quality and also to estimate image quality from any exposure dose.

  9. Biomonitoring of genotoxic and cytotoxic effects of gingival epithelial cells exposed to digital panoramic radiography

    Directory of Open Access Journals (Sweden)

    Anuradha Pai

    2012-01-01

    Full Text Available Objective: The aim of this study was to evaluate genotoxic and cytotoxic effects of low level ionizing radiation used in digital panoramic radiography on gingival epithelial cells. Materials and Methods: We included 50 healthy individuals advised for digital panoramic radiography for diagnostic purpose were included in this study. Demographic data and personal history of all subjects were recorded in a proforma before the examination. Gingival epithelial cells were obtained by gentle scraping with a modified cytobrush immediately before X-ray exposure and 10 ± 2 days later. Cytological preparations were stained according to the Feulgen/fast green method and analyzed under a light microscope. Micronuclei and degenerative nuclear alterations (pyknosis, karyolysis, karyorrhexis and condensed chromatin were scored. Results: The frequency of formation of micronuclei was not significant with regard to age, gender and after exposure to digital panoramic radiography ( P = 0.276. However this study showed significant increase in the frequencies of nuclear alterations like karyorrhexis, pyknosis, condensed chromatin, karyolysis and indicative of cell death ( P < 0.001. Conclusion: Panoramic radiographic examination does not induce genotoxic effect like micronuclei, but it does induce cytotoxic effects leading to cell death.

  10. Accuracy of Digital Bitewing Radiography versus Different Views of Digital Panoramic Radiography for Detection of Proximal Caries

    Science.gov (United States)

    Abdinian, Mehrdad; Razavi, Sayed Mohammad; Samety, Amir Abbas; Faghihian, Elham

    2015-01-01

    Objectives: Dental caries are common and have a high incidence among populations. Radiographs are essential for detecting proximal caries. The best technique should be recognized for accurate detection of caries. The aim of this study was to compare the accuracy of detection of proximal caries using intraoral bitewing, extraoral bitewing, improved interproximal panoramic, improved orthogonality panoramic and conventional panoramic radiographs. Materials and Methods: In this descriptive cross sectional study, 100 extracted human teeth with and without proximal caries were used. Intra and extraoral radiographs were taken. Images were evaluated and scored by two observers. Scores were compared with the histological gold standard. The diagnostic accuracy of radiographs was assessed by means of receiver operating characteristic (ROC) curve analysis (P<0.05). Results: Microscopic evaluation of proximal surfaces revealed that 54.8% of the surfaces were sound and 45.2% were carious (with different depths). The differences in the area under the ROC curve (Az value) among the five techniques were not statistically significant. Conclusion: Improved interproximal panoramic and extraoral bitewing radiographs were superior to conventional panoramic radiography for detection of proximal caries ex vivo and should be considered for patients with contraindications for intraoral radiographs. PMID:26622284

  11. Accuracy of digital subtraction radiography in combination with a contrast media in assessment of proximal caries depth.

    Science.gov (United States)

    Valizadeh, Solmaz; Ehsani, Sara; Esmaeili, Farzad; Tavakoli, Mohammad Amin

    2008-01-01

    Radiography is used to diagnose the demineralization process and carious lesions; however, conventional radiography and direct digital images do not show these lesions when the amount of demineralization is less than 40%. Digital subtraction radiography has recently been used to improve the diagnostic quality of these le-sions. The purpose of this study was to compare the caries depth estimated by digital subtraction radiog-raphy in combination with barium sulfate in diag-nosing proximal dental caries with histopathologic evaluation. In this study 30 molars and premolars (24 demineralized lesions with cavity, 8 without cavity) were studied. Direct digital images were taken (kVp: 68, mA: 8; t: 0.12 for premolars and t: 0.16 for molars) whereas the position of X-ray tube and CCD receptor and teeth was fixed. To prepare the second images 135 gr/L barium sulfate was used. The images obtained with the same exposure and geometry and then subtracted. The depth of the lesions in direct digital and subtracted images were assessed and compared with the depth measured in histopathologic assessments. The mean depths (± SD) of the lesions were 1.80 ± 0.77 mm in direct digital radiography, 2.32 ± 0.76 mm in subtracted images after barium sulfate treatment, and 2.51 ± 0.43 mm in histopathologic sections. The statistical difference between direct digital radiography and the other methods was significant (P digital subtraction radiography images have the potential to measure the depth of proximal caries with no significant difference with histopathologic evaluation.

  12. Accuracy of digital subtraction radiography in combination with a contrast media in assessment of proximal caries depth

    Directory of Open Access Journals (Sweden)

    Farzad Esmaeili

    2008-07-01

    Full Text Available Background and aims. Radiography is used to diagnose the demineralization process and carious lesions; however, conventional radiography and direct digital images do not show these lesions when the amount of demineralization is less than 40%. Digital subtraction radiography has recently been used to improve the diagnostic quality of these lesions. The purpose of this study was to compare the caries depth estimated by digital subtraction radiography in combination with barium sulfate in diagnosing proximal dental caries with histopathologic evaluation. Materials and methods. In this study 30 molars and premolars (24 demineralized lesions with cavity, 8 without cavity were studied. Direct digital images were taken (kVp: 68, mA: 8; t: 0.12 for premolars and t: 0.16 for molars whereas the position of X-ray tube and CCD receptor and teeth was fixed. To prepare the second images 135 gr/L barium sulfate was used. The images obtained with the same exposure and geometry and then subtracted. The depth of the lesions in direct digital and subtracted images were assessed and compared with the depth measured in histopathologic assessments. Results. The mean depths (± SD of the lesions were 1.80 ± 0.77 mm in direct digital radiography, 2.32 ± 0.76 mm in subtracted images after barium sulfate treatment, and 2.51 ± 0.43 mm in histopathologic sections. The statistical difference between direct digital radiography and the other methods was significant (P < 0.05. However, the differences were not statistically significant between subtracted images and histopathologic sections. The average intra-class correlation coefficient was 0.7241 (CI: 95%. Conclusion. The present study has demonstrated that digital subtraction radiography images have the potential to measure the depth of proximal caries with no significant difference with histopathologic evaluation.

  13. Application of digital radiography in evaluation of crack propagation rate in cast steel specimens

    Directory of Open Access Journals (Sweden)

    R. Sikora

    2009-07-01

    Full Text Available A technology that utilizes penetrating X-rays is one of the oldest non-destructive testing methods. Digital radiography combines modern digital image processing algorithms with traditional X-ray testing method. The following paper describes the present use of digital radiograms in flaw detection, and the use of identification and classification algorithms in detection of cracks that occur under the effect of thermal fatigue process in creep-resistant steel castings operating as structural elements in heat treatment furnaces. The number and length of cracks formed in specimens of Ø37×5 mm dimensions as a result of shock heating and cooling was evaluated. The test alloy was austenitic cast steel of 30Ni-18Cr type, containing 1.75% Nb and 0.93% Ti (wt.%. It has been indicated that the applied methods of non-destructive testing using digital radiography are fully successful in evaluation of the fatigue crack propagation rate in steel castings.

  14. Digital Acquisition Development for Fast Neutron Detectors

    Science.gov (United States)

    Seagren, T.; Mosby, S.; Mona Collaboration; Lansce P-27 Team

    2015-10-01

    The use of the Modular Neutron Array (MoNA) at FRIB requires a thorough understanding of how neutrons propagate through the array. This leads to the increasing importance of accuracy in detector response simulations, particularly in the case of FRIB's higher beam energies. An upcoming experiment at the LANSCE facility at Los Alamos National Lab will benchmark neutron propagation through the MoNA array and provide a more complete validation of the simulation software. LANSCE also hosts the Chi-Nu experiment, which seeks to measure fission output neutrons using the high-intensity neutron beams there. In both experiments, the instantaneous rate on the detectors involved is expected to be very high, due to the LANSCE/WNR beam structure. Therefore, waveform digitizers with on-board processing are required in order for the experiments to succeed. These digitizers provide on-board timing algorithms using FPGA firmware, and several tests were preformed in order to determine what the optimal timing filter settings were for a variety of detectors, including the plastic and liquid scintillators to be used in MoNA and Chi-Nu respectively. This work will inform the execution of the MoNA and Chi-Nu experiments at LANSCE. The details of the methods used and results will be presented. Supported by funding through Los Alamos National Lab and NSF Grant PHY-1506402.

  15. Quality assurance in digital dental radiography--justification and dose reduction in dental and maxillofacial radiology.

    Science.gov (United States)

    Hellstern, F; Geibel, M-A

    2012-01-01

    To evaluate the implementation of quality assurance requirements for digital dental radiography in routine clinical practice. The results should be discussed by radiation protection authorities in the context of the relevant legal requirements and current debates on radiation protection. Two hundred digital dental radiographs were randomly selected from the digital database of the Department of Dentistry's Dental and Maxillofacial Surgery Clinic, Ulm University, and evaluated for various aspects of image quality and compliance with radiographic documentation requirements. The dental films were prepared by different radiology assistants (RAs) using one of two digital intraoral radiographic systems: Sirona Heliodent DS, 60 kV, focal spot size: 0.7 mm (group A) or KaVo Gendex 765 DC, 65 kV, focal spot size: 0.4 mm (group B). Radiographic justification was documented in 70.5% of cases, and the radiographic findings in 76.5%. Both variables were documented in the patient records as well as in the software in 14% of cases. Clinical documentation of the required information (name of the responsible dentist and radiology assistant, date, patient name, department, tube voltage, tube current, exposure time, type of radiograph, film size, department and serial number of the dental radiograph) was 100% complete in all cases. Moreover, the department certified according to DIN ISO 9001:2008 specifications demonstrated complete clinical documentation of radiographic justifications and radiographic findings. The entire dentition was visible on 83% of the digital films. The visible area corresponded to the target region on 85.7% of the digital dental radiographs. Seven to 8.5% of the images were classified as "hypometric" or "hypermetric". This study indicates that improvements in radiology training and continuing education fordentists and dental staff performing x-ray examinations are needed to ensure consistent high quality of digital dental radiography. Implementation of

  16. [Comparative evaluation of six different body regions of the dog using analog and digital radiography].

    Science.gov (United States)

    Meyer-Lindenberg, Andrea; Ebermaier, Christine; Wolvekamp, Pim; Tellhelm, Bernd; Meutstege, Freek J; Lang, Johann; Hartung, Klaus; Fehr, Michael; Nolte, Ingo

    2008-01-01

    In this study the quality of digital and analog radiography in dogs was compared. For this purpose, three conventional radiographs (varying in exposure) and three digital radiographs (varying in MUSI-contrast [MUSI = MUlti Scale Image Contrast], the main post-processing parameter) of six different body regions of the dog were evaluated (thorax, abdomen, skull, femur, hip joints, elbow). The quality of the radiographs was evaluated by eight veterinary specialists familiar with radiographic images using a questionnaire based on details of each body region significant in obtaining a radiographic diagnosis. In the first part of the study the overall quality of the radiographs was evaluated. Within one region, 89.5% (43/48) chose a digital radiograph as the best image. Divided into analog and digital groups, the digital image with the highest MUSI-contrast was most often considered the best, while the analog image considered the best varied between the one with the medium and the one with the longest exposure time. In the second part of the study, each image was rated for the visibility of specific, diagnostically important details. After summarisation of the scores for each criterion, divided into analog and digital imaging, the digital images were rated considerably superior to conventional images. The results of image comparison revealed that digital radiographs showed better image detail than radiographs taken with the analog technique in all six areas of the body.

  17. Advanced digital detectors for neutron imaging.

    Energy Technology Data Exchange (ETDEWEB)

    Doty, F. Patrick

    2003-12-01

    Neutron interrogation provides unique information valuable for Nonproliferation & Materials Control and other important applications including medicine, airport security, protein crystallography, and corrosion detection. Neutrons probe deep inside massive objects to detect small defects and chemical composition, even through high atomic number materials such as lead. However, current detectors are bulky gas-filled tubes or scintillator/PM tubes, which severely limit many applications. Therefore this project was undertaken to develop new semiconductor radiation detection materials to develop the first direct digital imaging detectors for neutrons. The approach relied on new discovery and characterization of new solid-state sensor materials which convert neutrons directly to electronic signals via reactions BlO(n,a)Li7 and Li6(n,a)T.

  18. Identifying risk groups for osteoporosis by digital panoramic radiography

    Directory of Open Access Journals (Sweden)

    Satish Alapati

    2015-01-01

    Full Text Available Background: Osteoporosis is a disease characterized by low bone mass and microarchitectural deterioration of bone tissue, leading to bone fragility, and enhanced susceptibility to fractures. Dental radiographs, especially panoramic images, have been used to predict bone mineral density. A number of indices, (mandibular cortical index [MCI], mandibular cortical width [MCW], and panoramic mandibular index [PMI] have been developed to assess and quantify the quality of mandibular bone mass and to observe the signs of resorption. Objectives: The objectives of the study were to assess mental index (MI, MCW index, and PMI with bone density in identifying risk group for osteoporosis and also to investigate influence of age and gender on MI, MCI, and PMI. Materials and Methods: After obtaining consent, details regarding age, gender, systemic health status, and oral parafunctional habits were recorded in each patient. Then a digital panoramic radiograph was taken. The image thus obtained was subjected to calibrations and morphometric analysis using Digora version 2.7. The obtained values of indices were compared with the mean values of indices, to evaluate subjects whether they are prone to osteoporosis or not. The obtained information was subjected to statistical analysis for the significance of the parameters. Results: Data analysis showed that calibration indices were highly significant in the assessment of risk group for osteoporosis than noncalibration index. The subjects at a higher risk for development of osteoporosis were old-aged adults with higher prevalence being reported in women compared to male subjects. Conclusion: In conclusion, our results suggest that higher percentage of subjects with undetected decreased bone mineral density may be identified based on trained general dental practitioners analyses of their panoramic radiographs using simple screening analytical calibration MI and MCI.

  19. Diagnostic Accuracy of Image Enhancement in Intra-Oral Direct Digital Radiography in the Assessment of Interproximal Caries

    Directory of Open Access Journals (Sweden)

    Farzad Esmaeili

    2016-07-01

    Full Text Available Background The first commercial system for digital radiography was introduced in 1987, and it has evolved a great deal since then. Currently, it is possible to enhance images in digital radiography. Objectives The aim of this study is to evaluate the diagnostic accuracy of image enhancement in direct digital radiography as it relates to interproximal carries assessment. Materials and Methods Following extraction, 50 human teeth were kept in acidic gel (methyl cellulose + acetate buffer PH = 4.8 for 42 days at 37°C to cause caries before mounting. Direct digital radiography was then taken. Two filters were used: sharpen and emboss. Three radiologists evaluated the images with two weeks interval. The histologic assessments were gold standard. Additionally, SPSS 20 was used to draw an ROC curve and calculate AUC. Cohen’s kappa and interclass correlation coefficient (ICC were used to measure intra- and inter-observer reliability. Results For the emboss filter, sensitivity was 95%, specificity was 100%, and accuracy was 96%. For the sharpen filter, sensitivity was 88%, specificity was 100%, and accuracy was 90%. Also, the AUC for the emboss filter was 0.97, and it was 0.94 for the sharpen filter. Cohen’s simple kappa was in the range of excellent. Conclusions Using these filters in intra-oral direct digital radiography (especially the emboss filter can help some clinicians to increase diagnostic accuracy in the assessment of inter proximal caries of posterior teeth.

  20. SU-F-P-06: Moving From Computed Radiography to Digital Radiography: A Collaborative Approach to Improve Image Quality

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval, D; Mlady, G; Selwyn, R [University of New Mexico School of Medicine, Albuquerque, NM (United States); Valenti, D; Bateman, T; Norris, V [University of New Mexico Hospital, Albuquerque, New Mexico (United States)

    2016-06-15

    Purpose: To bring together radiologists, technologists, and physicists to utilize post-processing techniques in digital radiography (DR) in order to optimize image acquisition and improve image quality. Methods: Sub-optimal images acquired on a new General Electric (GE) DR system were flagged for follow-up by radiologists and reviewed by technologists and medical physicists. Various exam types from adult musculoskeletal (n=35), adult chest (n=4), and pediatric (n=7) were chosen for review. 673 total images were reviewed. These images were processed using five customized algorithms provided by GE. An image score sheet was created allowing the radiologist to assign a numeric score to each of the processed images, this allowed for objective comparison to the original images. Each image was scored based on seven properties: 1) overall image look, 2) soft tissue contrast, 3) high contrast, 4) latitude, 5) tissue equalization, 6) edge enhancement, 7) visualization of structures. Additional space allowed for additional comments not captured in scoring categories. Radiologists scored the images from 1 – 10 with 1 being non-diagnostic quality and 10 being superior diagnostic quality. Scores for each custom algorithm for each image set were summed. The algorithm with the highest score for each image set was then set as the default processing. Results: Images placed into the PACS “QC folder” for image processing reasons decreased. Feedback from radiologists was, overall, that image quality for these studies had improved. All default processing for these image types was changed to the new algorithm. Conclusion: This work is an example of the collaboration between radiologists, technologists, and physicists at the University of New Mexico to add value to the radiology department. The significant amount of work required to prepare the processing algorithms, reprocessing and scoring of the images was eagerly taken on by all team members in order to produce better quality

  1. The Comparison between Two Different Digital Panoramic Radiography Techniques in the Detection of Proximal Caries

    Directory of Open Access Journals (Sweden)

    Hossein Hoseini Zarch

    2013-03-01

    Full Text Available Introduction: Although proximal dental caries are very common, clinical examinations cannot detect them all. Panoramic radiography has been widely used in dentistry for both diagnosis and screening. This study aimed to investigate and compare the efficacy of two digital panoramic radiography techniques in the diagnosis of proximal caries. Methods: A total number of 60 patients referred to a dental radiology center, all had complete dental system and bitewing radiographies, were included. The patients were randomly divided into two groups of 30 patients. For the first and second groups, CR and DR images were obtained respectively. Images were obtained from the distal of the third tooth to the distal of the eighth. Bitewing images were compared with CR and DR images regarding the detection of caries. Kappa index and chi-squared statistics were employed to analyze the results. Results: There was a high agreement rate between bitewing images and CR (Kappa=0.775 and DR (Kappa=o.762 images in detecting caries. Also no significant difference was shown between CR and DR techniques in the detection of caries (0.543. However, DR and CR images are not efficient enough to be prescribed as the sole imaging technique to detect proximal caries. Conclusion: DR and CR techniques could be good imaging techniques for the detection of dental caries as a companion to clinical examinations

  2. Comparison between Two Digital Panoramic Radiography Techniques for Proximal Caries Detection

    Directory of Open Access Journals (Sweden)

    Mina Shafagh Motlagh

    2013-03-01

    Full Text Available Introduction: Although proximal dental caries are very common, clinical examinations cannot detect them all. Panoramic radiography has been widely used in dentistry for both diagnosis and screening. This study aimed to investigate and compare the efficacy of two digital panoramic radiography techniques in the diagnosis of proximal caries. Methods: A total number of 60 patients referred to a dental radiology center, all had complete dental system and bitewing radiographies, were included. The patients were randomly divided into two groups of 30 patients. For the first and second groups, CR and DR images were obtained respectively. Images were obtained from the distal of the third tooth to the distal of the eighth. Bitewing images were compared with CR and DR images regarding the detection of caries. Kappa index and chi-squared statistics were employed to analyze the results. Results: There was a high agreement rate between bitewing images and CR (Kappa=0.775 and DR (Kappa=o.762 images in detecting caries. Also no significant difference was shown between CR and DR techniques in the detection of caries (0.543. However, DR and CR images are not efficient enough to be prescribed as the sole imaging technique to detect proximal caries. Conclusion: DR and CR techniques could be good imaging techniques for the detection of dental caries as a companion to clinical examinations.

  3. Evaluation of the maxillary premolar roots dissociation using radiographic holders with conventional and digital radiography

    Directory of Open Access Journals (Sweden)

    Marcia Regina Ramalho da Silva Bardauil

    2010-09-01

    Full Text Available This in vivo study evaluated the dissociation quality of maxillary premolar roots combining variations of vertical and horizontal angulations by using X-ray holders (Rinn -XCP, and made a comparison between two types of intraoral radiography systems - conventional film (Kodak Insight, Rochester, USA and digital radiography (Kodak RVG 6100, Kodak, Rochester, USA. The study sample was comprised of 20 patients with a total of 20 maxillary premolars that were radiographed, using the paralleling angle technique (GP, with a 20º variation of the horizontal angle (GM and 25º variation of the horizontal angle combined with 15º vertical angle (GMV. Each image was independently analyzed by two experienced examiners. These examiners assigned a score to the diagnostic capability of root dissociation and the measurement of the distance between the apexes. Statistical data was derived using the Wilcoxon Signed Rank test, Friedman and T test. The means of the measured distances between buccal and lingual root apexes were greater for the GMV, which ranged from 2.3 mm to 3.3 mm. A statistically significant difference was found between GM and GMV when compared to GP with p < 0.01. An established best diagnostic dissociation roots image was found in the GMV. These results support the use of the anterior X-ray holders which offer a better combined deviation (GMV to dissociate maxillary premolar roots in both radiography systems.

  4. Construction of a physical phantom for quality control of digital radiography images

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Tayline T.; Azevedo, Priscila F.B. de; Vieira, Jose Wilson, E-mail: taylinetyene@hotmail.com, E-mail: priscilafbrasil@yahoo.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFPE), Recife, PE (Brazil); Oliveira, Alex C.H. de; Lima, Fernando R. Andrade, E-mail: falima@cnen.gov.br [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2014-07-01

    The advancement of technology in recent years has the production of increasingly sophisticated devices, in order thus to obtain medical images with high technical level and also facilitate the operation of the equipment. The phantoms were created to ensure a more accurate diagnosis with the minimum dose without exposing patients. Also, to obtain data and verify the performance of a radiography system with a view to ensuring the quality control standards. The objective of this paper is to present and validate a methodology for the construction of a phantom for the control of digital quality radiographic image. (author)

  5. Simulation study of pixel detector charge digitization

    Science.gov (United States)

    Wang, Fuyue; Nachman, Benjamin; Sciveres, Maurice; Lawrence Berkeley National Laboratory Team

    2017-01-01

    Reconstruction of tracks from nearly overlapping particles, called Tracking in Dense Environments (TIDE), is an increasingly important component of many physics analyses at the Large Hadron Collider as signatures involving highly boosted jets are investigated. TIDE makes use of the charge distribution inside a pixel cluster to resolve tracks that share one of more of their pixel detector hits. In practice, the pixel charge is discretized using the Time-over-Threshold (ToT) technique. More charge information is better for discrimination, but more challenging for designing and operating the detector. A model of the silicon pixels has been developed in order to study the impact of the precision of the digitized charge distribution on distinguishing multi-particle clusters. The output of the GEANT4-based simulation is used to train neutral networks that predict the multiplicity and location of particles depositing energy inside one cluster of pixels. By studying the multi-particle cluster identification efficiency and position resolution, we quantify the trade-off between the number of ToT bits and low-level tracking inputs. As both ATLAS and CMS are designing upgraded detectors, this work provides guidance for the pixel module designs to meet TIDE needs. Work funded by the China Scholarship Council and the Office of High Energy Physics of the U.S. Department of Energy under contract DE-AC02-05CH11231.

  6. Image quality assessment in panoramic dental radiography: a comparative study between conventional and digital systems.

    Science.gov (United States)

    Sabarudin, Akmal; Tiau, Yu Jin

    2013-02-01

    This study is designed to compare and evaluate the diagnostic image quality of dental panoramic radiography between conventional and digital systems. Fifty-four panoramic images were collected and divided into three groups consisting of conventional, digital with and without post processing image. Each image was printed out and scored subjectively by two experienced dentists who were blinded to the exposure parameters and system protocols. The evaluation covers of anatomical coverage and structures, density and image contrast. The overall image quality score revealed that digital panoramic with post-processing scored the highest of 3.45±0.19, followed by digital panoramic system without post-processing and conventional panoramic system with corresponding scores of 3.33±0.33 and 2.06±0.40. In conclusion, images produced by digital panoramic system are better in diagnostic image quality than that from conventional panoramic system. Digital post-processing visualization can improve diagnostic quality significantly in terms of radiographic density and contrast.

  7. Digital gray-level transformation for the reduction of redundant shadows in rotational panoramic radiography.

    Science.gov (United States)

    Hayakawa, Y; Wakoh, M; Yamamoto, K; Ueno, H; Kuroyanagi, K

    1990-08-01

    In rotational panoramic radiography, the tomographic motion in combination with a slit scanning method make an image layer wide. But some objects outside the image layer are hard to blur and they result to redundant shadows. The gray-level transformation, as one form of digital image processing for the reduction of these redundant shadows, was evaluated. Two methods, the gamma transformation and the histogram flattening method, were examined. A drum scanner was used as the image scanner. The panoramic image on the x-ray film was turned into an 8 bit digital image on the image memory, which had the size of a 512 x 480 matrix. In rotational panoramic radiography, there are low density and contrast regions where redundant shadows of the cervical vertebrae and the mandibular ramus are superimposed on the tomographic image. The histogram of the gray-level was suppressed for the lower gray-levels. The stretching of this gray-level distribution was effective in the reducing redundant shadows. When processed by gamma transformation, the smaller gamma coefficient below 1.0 clarified the tomographic image, and when processed by the histogram flattening method, the setting of the level (L) value around 64-128 effectively reduced the redundant shadows. However, the effectiveness of both gray-level transformations was greatest in restricted cases in which the area where redundant shadows were superimposed on the tomographic image was comparatively large.

  8. Accuracy of digital peripical radiography and cone-beam computed tomography in detecting external root resorption

    Energy Technology Data Exchange (ETDEWEB)

    Creanga, Adriana Gabriela [Division of Dental Diagnostic Science, Rutgers School of Dental Medicine, Newark (United States); Geha, Hassem; Sankar, Vidya; Mcmahan, Clyde Alex; Noujeim, Marcel [University of Texas Health Science Center San Antonio, San Antonio (United States); Teixeira, Fabrico B. [Dept. of Endodontics, University of Iowa, Iowa City (United States)

    2015-09-15

    The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital radiography using image plates and with CBCT. Two sets of intraoral images were acquired per tooth: orthogonal (PA) which was the conventional periapical radiograph and mesioangulated (SET). Four readers were asked to rate their confidence level in detecting and locating the lesions. Receiver operating characteristic (ROC) analysis was performed to assess the accuracy of each modality in detecting the presence of lesions, the affected surface, and the affected level. Analysis of variation was used to compare the results and kappa analysis was used to evaluate interobserver agreement. A significant difference in the area under the ROC curves was found among the three modalities (P=0.0002), with CBCT (0.81) having a significantly higher value than PA (0.71) or SET (0.71). PA was slightly more accurate than SET, but the difference was not statistically significant. CBCT was also superior in locating the affected surface and level. CBCT has already proven its superiority in detecting multiple dental conditions, and this study shows it to likewise be superior in detecting and locating incipient external root resorption.

  9. Ongoing quality control in digital radiography: Report of AAPM Imaging Physics Committee Task Group 151.

    Science.gov (United States)

    Jones, A Kyle; Heintz, Philip; Geiser, William; Goldman, Lee; Jerjian, Khachig; Martin, Melissa; Peck, Donald; Pfeiffer, Douglas; Ranger, Nicole; Yorkston, John

    2015-11-01

    Quality control (QC) in medical imaging is an ongoing process and not just a series of infrequent evaluations of medical imaging equipment. The QC process involves designing and implementing a QC program, collecting and analyzing data, investigating results that are outside the acceptance levels for the QC program, and taking corrective action to bring these results back to an acceptable level. The QC process involves key personnel in the imaging department, including the radiologist, radiologic technologist, and the qualified medical physicist (QMP). The QMP performs detailed equipment evaluations and helps with oversight of the QC program, the radiologic technologist is responsible for the day-to-day operation of the QC program. The continued need for ongoing QC in digital radiography has been highlighted in the scientific literature. The charge of this task group was to recommend consistency tests designed to be performed by a medical physicist or a radiologic technologist under the direction of a medical physicist to identify problems with an imaging system that need further evaluation by a medical physicist, including a fault tree to define actions that need to be taken when certain fault conditions are identified. The focus of this final report is the ongoing QC process, including rejected image analysis, exposure analysis, and artifact identification. These QC tasks are vital for the optimal operation of a department performing digital radiography.

  10. Ongoing quality control in digital radiography: Report of AAPM Imaging Physics Committee Task Group 151

    Energy Technology Data Exchange (ETDEWEB)

    Jones, A. Kyle, E-mail: kyle.jones@mdanderson.org; Geiser, William [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Heintz, Philip [Department of Radiology, University of New Mexico, Albuquerque, New Mexico 87104 (United States); Goldman, Lee [Hartford Hospital, Hartford, Connecticut 06102 (United States); Jerjian, Khachig [Hoag Memorial Hospital, Newport Beach, California 92658 (United States); Martin, Melissa [Therapy Physics, Inc., Gardena, California 90248 (United States); Peck, Donald [Henry Ford Health System, Detroit, Michigan 48202 (United States); Pfeiffer, Douglas [Boulder Community Foothills Hospital, Boulder, Colorado 80303 (United States); Ranger, Nicole [Landauer, Inc., Glenwood, Illinois 60425 (United States); Yorkston, John [Carestream Health, Inc., Rochester, New York 14615 (United States)

    2015-11-15

    Quality control (QC) in medical imaging is an ongoing process and not just a series of infrequent evaluations of medical imaging equipment. The QC process involves designing and implementing a QC program, collecting and analyzing data, investigating results that are outside the acceptance levels for the QC program, and taking corrective action to bring these results back to an acceptable level. The QC process involves key personnel in the imaging department, including the radiologist, radiologic technologist, and the qualified medical physicist (QMP). The QMP performs detailed equipment evaluations and helps with oversight of the QC program, the radiologic technologist is responsible for the day-to-day operation of the QC program. The continued need for ongoing QC in digital radiography has been highlighted in the scientific literature. The charge of this task group was to recommend consistency tests designed to be performed by a medical physicist or a radiologic technologist under the direction of a medical physicist to identify problems with an imaging system that need further evaluation by a medical physicist, including a fault tree to define actions that need to be taken when certain fault conditions are identified. The focus of this final report is the ongoing QC process, including rejected image analysis, exposure analysis, and artifact identification. These QC tasks are vital for the optimal operation of a department performing digital radiography.

  11. The use of x-ray micro-digital radiography for clay material inspection

    Science.gov (United States)

    Suparta, Gede B.; Louk, Andreas C.; Kurniasari, Herlina; Wiguna, Gede A.

    2014-06-01

    An x-ray micro-digital radiography (μ-DR) system has been developed at the Gadjah Mada University Indonesia. The μ- DR system was developed as an add-on unit on an x-ray Diffraction (XRD) system using one extra beam-port as its radiation source. A fluorescence screen encapsulated in a dark tube then coupled by a CCD camera was used as an imaging plate. The radiography objects were some sample clays for earthen or ceramic material of handicraft. The clays differ by particle size, namely: 40 mesh, 60 mesh, 80 mesh, and 100 mesh. The objects were put in front of the imaging plate and then they were exposed by x-ray beam. The image formed on the screen was captured by the CCD camera and then it was converted into digital microradiograph of a size of 720x576. Then, after noise suppression process and normalization procedure, the microradiograph were compared each other by considering particle size. This facility can be used as a non-destructive and testing material studies for examining the quality of earthen or ceramic handicraft.

  12. Evaluation of the Radiopacities of Bulk-fill Restoratives Using Two Digital Radiography Systems.

    Science.gov (United States)

    Yasa, E; Yasa, B; Aglarci, O S; Ertas, E T

    2015-01-01

    This study investigated the radiopacity values of bulk-fill restoratives by using two digital radiography systems. Nine bulk-fill restoratives and a conventional composite were used in the study. Six disc-shaped specimens were prepared from each of these materials, three each at thicknesses of 1 mm and 2 mm, and tooth slices with these same thicknesses were obtained. As a control, an aluminum step wedge varying in thickness from 0.5 to 10 mm in was used. Three specimens of each of the materials, together with the tooth slice and the aluminum step wedge, were placed over a complementary metal oxide semiconductor (CMOS) sensor and a storage photostimulable phosphor (PPS) plate system and exposed using a dental x-ray unit. The images were analyzed using a software program to measure the mean gray values (MGVs). Five measurements were obtained from each of the restorative materials, the enamel, the dentin, and the stepwedge. The MGVs were converted to the equivalent aluminum thicknesses. Three-way analysis of variance (ANOVA) was used to determine the significance of the differences among the groups. A Tukey test was applied for pairwise comparisons (psystem showed significantly higher radiopacity values than the PSP system. In conclusion, all investigated bulk-fill restoratives passed the International Organization for Standardization and American National Standard Institute/American Dental Association requirements for radiopacity values when evaluated with the two digital radiography systems.

  13. Standard practice for digital imaging and communication nondestructive evaluation (DICONDE) for computed radiography (CR) test methods

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice facilitates the interoperability of computed radiography (CR) imaging and data acquisition equipment by specifying image data transfer and archival storage methods in commonly accepted terms. This practice is intended to be used in conjunction with Practice E2339 on Digital Imaging and Communication in Nondestructive Evaluation (DICONDE). Practice E2339 defines an industrial adaptation of the NEMA Standards Publication titled Digital Imaging and Communications in Medicine (DICOM, see http://medical.nema.org), an international standard for image data acquisition, review, storage and archival storage. The goal of Practice E2339, commonly referred to as DICONDE, is to provide a standard that facilitates the display and analysis of NDE results on any system conforming to the DICONDE standard. Toward that end, Practice E2339 provides a data dictionary and a set of information modules that are applicable to all NDE modalities. This practice supplements Practice E2339 by providing information objec...

  14. Evaluation of Singh index for assessment of osteoporosis using digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hauschild, O. [Department of Orthopaedic Surgery and Traumatology, University Medical Center Freiburg (Germany)], E-mail: oliver.hauschild@uniklinik-freiburg.de; Ghanem, N. [Department for Diagnostic Radiology, University Medical Center Freiburg (Germany)], E-mail: nadir.ghanem@uniklinik-freiburg.de; Oberst, M. [Department of Orthopaedic Surgery and Traumatology, University Medical Center Freiburg (Germany)], E-mail: michael.oberst@uniklinik-freiburg.de; Baumann, T. [Department for Diagnostic Radiology, University Medical Center Freiburg (Germany)], E-mail: tobias.baumann@uniklinik-freiburg.de; Kreuz, P.C. [Department of Orthopaedic Surgery and Traumatology, University Medical Center Freiburg (Germany)], E-mail: peter.kreuz@uniklinik-freiburg.de; Langer, M. [Department for Diagnostic Radiology, University Medical Center Freiburg (Germany)], E-mail: mathias.langer@uniklinik-freiburg.de; Suedkamp, N.P. [Department of Orthopaedic Surgery and Traumatology, University Medical Center Freiburg (Germany)], E-mail: norbert.suedkamp@uniklinik-freiburg.de; Niemeyer, P. [Department of Orthopaedic Surgery and Traumatology, University Medical Center Freiburg (Germany)], E-mail: philipp.niemeyer@uniklinik-freiburg.de

    2009-07-15

    Evaluation of Singh index (SI) as a simple means for estimating bone mass on radiographs has been subject of numerous studies. All of these studies used plain film radiographs for assessment of SI. Digital radiography may improve validity and reliability of SI assessment. Aim of this study was to evaluate SI gradings assessed on digital radiographs. Digital pelvic radiographs of 100 patients were graded using SI by five independent observers (two radiologists, three traumatologists) blinded to dual energy X-ray absorptiometry (DXA) results and re-graded by all observers for assessment of intraobserver agreement. SI was correlated with DXA measurements and after grouping the patients according to World Health Organisation (WHO) criteria (osteoporosis, osteopenia, normal). Logistic regression analysis was performed in order to identify influential parameters on the SI grading process. Mean intraobserver agreement was 0.648 {+-} 0.18 (Kendall's Tau) and 0.43 {+-} 0.28 (kappa). Mean interobserver agreement was 0.488 {+-} 0.193 (Kendall's Tau) and 0.199 {+-} 0.248 (kappa). Mean correlation between SI and trochanteric BMD and T scores was 0.219 {+-} 0.04 and 0.210 {+-} 0.05 (Spearman's coefficient). Only one observer (senior radiologist) reached the significance level after grouping the patients' DXA results according to WHO criteria and correlating the results with SI gradings. Logistic regression analysis revealed a significant influence of trochanteric T score in two observers while other variable parameters failed to reach the significance level. Even though we found reasonable intraobserver agreement assessment of SI is highly subjective and interobserver agreement is generally poor. Moreover, using digital radiography could not improve correlation with DXA measurements.

  15. Accuracy of Digital Subtraction Radiography in the Detection of Vertical Root Fractures.

    Science.gov (United States)

    Queiroz, Polyane Mazucatto; Nascimento, Helena Aguiar Ribeiro; da Paz, Thais Diniz Jacome; Anacleto, Felipe Nogueira; Freitas, Deborah Queiroz

    2016-06-01

    The objective of this study was to evaluate the accuracy of digital subtraction radiography in the diagnosis of vertical root fractures (VRFs). Twenty decoronated uniradicular human teeth were placed in the alveoli of a dry mandible and radiographed twice, first without (unfilled roots) and then with (filled roots) a gutta-percha cone placed into the root canal. Roots were then removed from the dry mandible, and vertical fractures were created with the aid of a universal testing machine. The fractured roots were repositioned in the mandibular alveoli and again radiographed twice. Radiographic images were subtracted by using the Regeemy software in 3 test situations: group 1, initial radiographic images of unfilled roots and images of fractured or non-fractured unfilled roots; group 2, initial radiographic images of unfilled roots and images of fractured or non-fractured filled roots; and group 3, initial radiographic images of filled roots and images of fractured or non-fractured filled roots. Three examiners evaluated all the original digital radiographs, as well as the subtracted images, for the presence or absence of VRFs. Numerical data were subject to statistical analysis with the use of receiver operator characteristic (ROC) curves. The areas under the ROC curve for groups 1, 2, and 3 were 0.86, 0.73, and 0.66, respectively. For the original digital radiographs, areas under the ROC curve were 0.80 (without gutta-percha) and 0.73 (with gutta-percha). No statistically significant differences were found between subtracted and original images. Digital subtraction radiography could be considered as an alternative tool for the investigation of VRFs because of its comparable diagnostic accuracy to existing methods. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  16. Digital autoradiography using silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Overdick, M.

    1998-05-01

    Spatially resolving radiation detection systems operating in real time can be used to acquire autoradiographic images. An overview over alternatives to traditional autoradiography is given and the special features of these filmless methods are discussed. On this basis the design of a system for digital autoradiography using silicon strip detectors is presented. Special emphasis is put on the physical background of the detection process in the semiconductor and on the self-triggering read-out technique. The practical performance of the system is analyzed with respect to energy and spatial resolution. This analysis is complemented by case studies from cell biology (especially electrophoresis), botany and mineralogy. Also the results from a time-resolved autoradiographic experiment are presented. (orig.) 80 refs.

  17. A method to incorporate the effect of beam quality on image noise in a digitally reconstructed radiograph (DRR) based computer simulation for optimisation of digital radiography

    Science.gov (United States)

    Moore, Craig S.; Wood, Tim J.; Saunderson, John R.; Beavis, Andrew W.

    2017-09-01

    The use of computer simulated digital x-radiographs for optimisation purposes has become widespread in recent years. To make these optimisation investigations effective, it is vital simulated radiographs contain accurate anatomical and system noise. Computer algorithms that simulate radiographs based solely on the incident detector x-ray intensity (‘dose’) have been reported extensively in the literature. However, while it has been established for digital mammography that x-ray beam quality is an important factor when modelling noise in simulated images there are no such studies for diagnostic imaging of the chest, abdomen and pelvis. This study investigates the influence of beam quality on image noise in a digital radiography (DR) imaging system, and incorporates these effects into a digitally reconstructed radiograph (DRR) computer simulator. Image noise was measured on a real DR imaging system as a function of dose (absorbed energy) over a range of clinically relevant beam qualities. Simulated ‘absorbed energy’ and ‘beam quality’ DRRs were then created for each patient and tube voltage under investigation. Simulated noise images, corrected for dose and beam quality, were subsequently produced from the absorbed energy and beam quality DRRs, using the measured noise, absorbed energy and beam quality relationships. The noise images were superimposed onto the noiseless absorbed energy DRRs to create the final images. Signal-to-noise measurements in simulated chest, abdomen and spine images were within 10% of the corresponding measurements in real images. This compares favourably to our previous algorithm where images corrected for dose only were all within 20%.

  18. Digital versus conventional panoramic radiography in predicting inferior alveolar nerve injury after mandibular third molar removal.

    Science.gov (United States)

    Szalma, József; Lempel, Edina; Jeges, Sára; Olasz, Lajos

    2012-03-01

    The aim of the study was to compare the accuracy of conventional and digital panoramic radiography (OPG) in relation to 4 specific high-risk signs (interruption of the superior cortical line, diversion, narrowing of the canal, and dark band of the root), which would indicate a close anatomic relationship between third molar roots and the inferior alveolar canal.Four hundred mandibular third molar surgical removals after conventional and 272 after digital radiographs were evaluated in the study. The association between postoperative inferior alveolar nerve (IAN) paresthesia and the presence of any preoperative high-risk signs in the OPG was investigated. Bivariate and multivariate logistic regression analyses were completed to compare the accuracy of conventional and digital radiographic techniques detecting high-risk signs predicting possible IAN paresthesia.Digital OPG results showed significantly higher sensitivity in diversion (P = 0.014) and narrowing (P paresthesia, whereas low positive predictive values indicate both imaging techniques as inadequate screening methods for predicting IAN paresthesia after mandibular third molar removal.

  19. Application of GaAs and CdTe photoconductor detectors to X-ray flash radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mathy, F.; Cuzin, M.; Gagelin, J.J.; Mermet, R.; Piaget, B.; Rustique, J.; Verger, L. (CEA, Direction des Technologies Avancees, Lab. d' Electronique, de Technologie et d' Instrumentation, DSYS, 38 - Grenoble (France)); Hauducoeur, A.; Nicolas, P.; Le Dain, L.; Hyvernage, M. (CEA, Direction des Applications Militaires, 77 - Courtry (France))

    1992-11-15

    Some insulating GaAs and CdTe:Cl photoconductor probes were qualified on high energy X-ray single-shot flash generators. The estimated minimum detected dose per flash corresponding to a 230 mrad direct beam attenuated by 200 mm lead was 20 [mu]rad. The dynamic range was about 4 decades in amplitude or charge, with a good linearity. Such detectors, by locating the origin of the parasitic scattered beam, could be used to eliminate this parasitic beam in X-ray flash radiography in detonics experiments. Imaging possibilities are mentioned, as well as X-ray generator monitoring with such detectors or with neutron preirradiated photoconductors. (orig.).

  20. Application of GaAs and CdTe photoconductor detectors to x-ray flash radiography

    Energy Technology Data Exchange (ETDEWEB)

    Mathy, F.; Cuzin, M.; Gagelin, J.J.; Mermet, R.; Piaget, B.; Rustique, J.; Verger, L. [CEA Centre d`Etudes de Grenoble, 38 (FR). Direction des Technologies Avancees; Hauducoeur, A.; Nicolas, P.; Le Dain, L.; Hyvernage, M. [CEA Centre d`Etudes de Vaujours, 77 - Courtry (FR)

    1991-12-31

    Semi-insulating GaAs and CdTe:Cl photoconductor probes were qualified on high energy X ray single shot flash generators. The estimated minimum detected dose per flash corresponding to a 230 mrad direct beam attenuated by 200 mm lead was 20 {mu}rad. The dynamic range was about 4 decades in amplitude or charges, with a good linearity. Such detectors, by locating the origin of the parasitic scattered beam, could be used to eliminate this parasitic beam in X ray flash radiography in detonics experiments. Imaging possibilities are mentioned, as well as X ray generator monitoring with such detectors or with neutron preirradiated photoconductors.

  1. A study of scattered radiation effect on digital radiography imaging system

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Cheol Ha [Dept. of Radiological Science, Dongseo University, Busan (Korea, Republic of)

    2017-03-15

    Scattered radiation is inherent phenomenon of x-ray, which occurs to the subject (or patient). Therefore it cannot be avoidable but also interacts as serious noise factor because the only meaningful information on x-ray radiography is primary x-ray photons. The purpose of this study was to quantify scattered radiation for various shooting parameters and to verify the effect of anti-scatter grid. We employed beam stopper method to characterize scatter to primary ratio. To evaluate effect on the projection images calculated contrast to noise ratio of given shooting parameters. From the experiments, we identified the scattered radiation increases in thicker patient and smaller air gap. Moreover, scattered radiation degraded contrast to noise ratio of the projection images. We find out that the anti-scatter grid rejected scattered radiation effectively, however there were not fewer than 100% of scatter to primary ratio in some shooting parameters. The results demonstrate that the scattered radiation was serious problem of medical x-ray system, we confirmed that the scattered radiation was not considerable factor of digital radiography.

  2. Effects of dose reduction on the detectability of standardized radiolucent lesions in digital panoramic radiography.

    Science.gov (United States)

    Dula, K; Sanderink, G; van der Stelt, P F; Mini, R; Buser, D

    1998-08-01

    Dose reduction in digital panoramic radiography was studied. Intentional underexposure was performed with the Orthophos DS while six different human mandibles were radiographed. Exposure settings were 69 kV/15 mA (standard), 64 kV/16 mA, and 60 kV/16 mA. Standardized spherical defects, each either 1 or 1.25 mm in diameter, were simulated in 288 of 432 images, and seven observers decided whether defects were present or not. Areas under the receiver operating characteristics curves were calculated. They showed no significant differences in the detectability of the 1-mm defect at 69, 64, or 60 kV. For the 1.25-mm defect, no difference was found between the 69 and 60 kV images, but a statistically significant different detectability was found for 64 kV images in comparison with both 69 and 60 kV images. A dose reduction of up to 43% was ascertained with a Pedo-RT-Humanoid phantom when panoramic radiography was performed at 60 kV/16 mA. The conclusion is that with the Orthophos DS, it seems possible to reduce the dose rate of x-rays without loss of diagnostic quality in the case of radiolucent changes.

  3. Digital panoramic radiography versus cone beam computed tomography in the delineation of maxillomandibular tumors.

    Science.gov (United States)

    Almeida-Barros, Renata Quirino de; Abilio, Vanessa Maria Freire; Yamamoto, Angela Toshie Araki; Melo, Daniela Pita de; Godoy, Gustavo Pina; Bento, Patricia Meira

    2015-01-01

    This research aimed to compare the efficacy of digital panoramic radiography (DPR) with that of cone beam computed tomography (CBCT) for delineation of odontogenic and nonodontogenic tumors. From November 2009 through March 2011, 23 tumors in the maxillomandibular complex were diagnosed by histopathological examination. All DPRs and CBCTs were obtained and analyzed by a single previously calibrated radiologist, who considered the following radiographic aspects: clarity of the lesion edges, relation with dental elements, involvement of adjacent anatomical structures, cortical bone expansion and disruption, and, if present, type of involved anatomical structures and site of bone expansion and disruption. Of 23 patients, 15 (65.2%) were male and 8 (34.8%) were female. The tumor was classified as odontogenic in 73.9% of patients and nonodontogenic in 26.1% of patients. Analysis revealed that 56.5% of the tumors were located in the mandible, 34.8% in the maxilla, and 8.7% in both arches. For all analyzed variables, CBCTs offered more accurate details than did DPRs. Panoramic radiography should not be the examination of choice to visualize lesions in the maxillomandibular complex.

  4. A dynamic material discrimination algorithm for dual MV energy X-ray digital radiography.

    Science.gov (United States)

    Li, Liang; Li, Ruizhe; Zhang, Siyuan; Zhao, Tiao; Chen, Zhiqiang

    2016-08-01

    Dual-energy X-ray radiography has become a well-established technique in medical, industrial, and security applications, because of its material or tissue discrimination capability. The main difficulty of this technique is dealing with the materials overlapping problem. When there are two or more materials along the X-ray beam path, its material discrimination performance will be affected. In order to solve this problem, a new dynamic material discrimination algorithm is proposed for dual-energy X-ray digital radiography, which can also be extended to multi-energy X-ray situations. The algorithm has three steps: α-curve-based pre-classification, decomposition of overlapped materials, and the final material recognition. The key of the algorithm is to establish a dual-energy radiograph database of both pure basis materials and pair combinations of them. After the pre-classification results, original dual-energy projections of overlapped materials can be dynamically decomposed into two sets of dual-energy radiographs of each pure material by the algorithm. Thus, more accurate discrimination results can be provided even with the existence of the overlapping problem. Both numerical and experimental results that prove the validity and effectiveness of the algorithm are presented.

  5. Comparison of low-contrast detail perception on storage phosphor radiographs and digital flat panel detector images.

    Science.gov (United States)

    Peer, S; Neitzel, U; Giacomuzzi, S M; Peer, R; Gassner, E; Steingruber, I; Jaschke, W

    2001-03-01

    A contrast detail analysis was performed to compare perception of low-contrast details on X-ray images derived from digital storage phosphor radiography and from a flat panel detector system based on a cesium iodide/amorphous silicon matrix. The CDRAD 2.0 phantom was used to perform a comparative contrast detail analysis of a clinical storage phosphor radiography system and an indirect type digital flat panel detector unit. Images were acquired at exposure levels comparable to film speeds of 50/100/200/400 and 800. Four observers evaluated a total of 50 films with respect to the threshold contrast for each detail size. The numbers of correctly identified objects were determined for all image subsets. The overall results show that low-contrast detail perception with digital flat panel detector images is better than with state of the art storage phosphor screens. This is especially true for the low-exposure setting, where a nearly 10% higher correct observation ratio is reached. Given its high detective quantum efficiency the digital flat panel technology based on the cesium iodide scintillator/amorphous silicon matrix is best suited for detection of low-contrast detail structures, which shows its high potential for clinical imaging.

  6. Dosimetry and optimization in digital radiography based on the detail contrast resolution

    Energy Technology Data Exchange (ETDEWEB)

    Gomes B, W. O. [Instituto Federal da Bahia, Rua Emidio dos Santos s/n, Barbalho 40301-015, Salvador de Bahia (Brazil); Gomes de C, A., E-mail: wilsonottobatista@gmail.com [Secretaria de Saude do Estado da Bahia, Salvador de Bahia (Brazil)

    2016-10-15

    In digital radiography, computed radiography systems (CR) and portable panels a-Si (DR) are adapted to equipment previously used for the system screen / film. Therefore it maintains the characteristics as grid, filtration, yield, etc. Otherwise, the systems dedicated with a-Si panels (DR), are designed to operate with these image receptors. The ability to detect in low contrast details is reduced for all systems with increasing ratio of scattered radiation / primary radiation. In this context there is a need to acquire experience and adjust exposure protocols to ensure the quality of the image with maintaining kerma values in the surface as low as possible. The contrast resolution is defined as the ability of the system to distinguish similar degrees of attenuation of the object and is a parameter used to maintain the quality index and comparison between different systems. The protocols were: chest (90 and 102 kV with the range of 2-20 m As) and abdomen (80 kV in the range of 10-80 m As). Kerma values were evaluated with a solid state sensors. Based on analysis of these curves C-D, which identified the technique would imply a lower kerma input surface while maintaining image quality from the point of view of contrast-detail resolution. The results show that the IQFinv varies little throughout the range of m As, while the value of kerma varies linearly with in m As. Also, the complete analysis of the curves indicate that there was an increase in the definition of detail with increasing m As. The conclusion is that, in the transition phase of the new receivers are needed to assess and adjust practiced protocols to ensure the quality index of the image taking into account aspects of radiation protection of the patient. And even with digital technology, good radiographic technique should be practiced. (Author)

  7. Multi-energy method of digital radiography for imaging of biological objects

    Science.gov (United States)

    Ryzhikov, V. D.; Naydenov, S. V.; Opolonin, O. D.; Volkov, V. G.; Smith, C. F.

    2016-03-01

    This work has been dedicated to the search for a new possibility to use multi-energy digital radiography (MER) for medical applications. Our work has included both theoretical and experimental investigations of 2-energy (2E) and 3- energy (3D) radiography for imaging the structure of biological objects. Using special simulation methods and digital analysis based on the X-ray interaction energy dependence for each element of importance to medical applications in the X-ray range of energy up to 150 keV, we have implemented a quasi-linear approximation for the energy dependence of the X-ray linear mass absorption coefficient μm (E) that permits us to determine the intrinsic structure of the biological objects. Our measurements utilize multiple X-ray tube voltages (50, 100, and 150 kV) with Al and Cu filters of different thicknesses to achieve 3-energy X-ray examination of objects. By doing so, we are able to achieve significantly improved imaging quality of the structure of the subject biological objects. To reconstruct and visualize the final images, we use both two-dimensional (2D) and three-dimensional (3D) palettes of identification. The result is a 2E and/or 3E representation of the object with color coding of each pixel according to the data outputs. Following the experimental measurements and post-processing, we produce a 3D image of the biological object - in the case of our trials, fragments or parts of chicken and turkey.

  8. Reproducibility between conventional and digital periapical radiography for bone height measurement

    Directory of Open Access Journals (Sweden)

    Miguel Simancas-Pallares

    2015-10-01

    Full Text Available Background. Several diagnostic aids are available for bone height measurement. Digital and conventional radiographs are the two ones most used in Dentistry. Few studies accounting for accuracy and precision have been conducted to compare these methods. Objective. The aim of this study was to estimate reproducibility between conventional and digital periapical radiography in bone height measurement in patients with chronic periodontitis. Methods. a consistency diagnostic test study was performed. 136 patients with chronic periodontitis were included, selecting the worst prognosis teeth and two radiographs -conventional and digital- were taken for each one. Two experienced and blinded examiners performed radiographic measurements. Reproducibility was obtained through Lin's concordance correlation coefficient by using the statistical package STATA™ for Windows. Results. Average age was 38.8 (SD: 9.9 and 61.6 % were female patients. 125 pairs of matched radiographs for 1000 measurements were evaluated. Overall reproducibility between the methods for mesial and distal measurements were 0.62 (95% CI: 0.55-0.70 and 0.64 (95% CI: 0.57-0.71 respectively. Conclusions. Reproducibility between methods was considered poor, including subgroup analysis, therefore, reproducibility between methods is minimal. Usage of these methods in periodontics should be made implementing the whole knowledge of the technical features and the advantages of these systems.

  9. A comparison of digital radiography systems in terms of effective detective quantum efficiency.

    Science.gov (United States)

    Bertolini, Marco; Nitrosi, Andrea; Rivetti, Stefano; Lanconelli, Nico; Pattacini, Pierpaolo; Ginocchi, Vladimiro; Iori, Mauro

    2012-05-01

    The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE). The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report # 31 simulating the attenuation and scatter characteristics of the adult human thorax. The MTF (eMTF) was measured by using an edge test placed at the frontal surface of the phantom, the NNPS (eNNPS) was calculated from images of the phantom acquired at three different exposure levels covering the operating range of the system (E(0), which is the exposure at which a system is normally operated, 1/3 E(0), and 3 E0), and scatter measurements were assessed by using a beam-stop technique. The integral of DQE (IDQE) and eDQE (IeDQE) was calculated over the whole spatial frequency range. The eMTF results demonstrate degradation due to magnification and the presence of scattered radiation. The eNNPS was influenced by the grid presence, and in some systems, it contained structured noise. At typical clinical exposure levels, the magnitude of eDQE(0) with respect to DQE(0) at RQA9 beam conditions was 13%, 17%, 16%, 36%, and 24%, respectively, for Carestream DRX-1, Carestream DRX-1C, Carestream Direct View CR975, Philips Digital Diagnost VM, and GE Revolution XR/d. These results were confirmed by the ratio of IeDQE and IDQE in the same conditions. The authors confirm the robustness and reproducibility of the eDQE method. As expected, the DR systems performed better than the CR systems due to their

  10. A comparison of digital radiography systems in terms of effective detective quantum efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Bertolini, Marco; Nitrosi, Andrea; Rivetti, Stefano; Lanconelli, Nico; Pattacini, Pierpaolo; Ginocchi, Vladimiro; Iori, Mauro [Department of Advanced Technology, Medical Physics Unit, Azienda Ospedaliera ASMN, Istituto di Ricovero e Cura a Carattere Scientifico, Reggio Emilia 42123 (Italy); Fisica Medica, Ospedale di Sassuolo S.p.A., Modena 41049 (Italy); Alma Mater Studiorum, Physics Department, University of Bologna, Bologna 40127 (Italy); Department of Diagnostic Imaging, Radiology Unit, Azienda Ospedaliera ASMN, Istituto di Ricovero e Cura a Carattere Scientifico, Reggio Emilia 42123 (Italy); Department of Diagnostic Imaging, Radiology Unit, Azienda USL, Reggio Emilia 42122 (Italy); Department of Advanced Technology, Medical Physics Unit, Azienda Ospedaliera ASMN, Istituto di Ricovero e Cura a Carattere Scientifico, Reggio Emilia 42123 (Italy)

    2012-05-15

    Purpose: The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE). Methods: The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report no. 31 simulating the attenuation and scatter characteristics of the adult human thorax. The MTF (eMTF) was measured by using an edge test placed at the frontal surface of the phantom, the NNPS (eNNPS) was calculated from images of the phantom acquired at three different exposure levels covering the operating range of the system (E{sub 0}, which is the exposure at which a system is normally operated, 1/3 E{sub 0}, and 3 E0), and scatter measurements were assessed by using a beam-stop technique. The integral of DQE (IDQE) and eDQE (IeDQE) was calculated over the whole spatial frequency range. Results: The eMTF results demonstrate degradation due to magnification and the presence of scattered radiation. The eNNPS was influenced by the grid presence, and in some systems, it contained structured noise. At typical clinical exposure levels, the magnitude of eDQE(0) with respect to DQE(0) at RQA9 beam conditions was 13%, 17%, 16%, 36%, and 24%, respectively, for Carestream DRX-1, Carestream DRX-1C, Carestream Direct View CR975, Philips Digital Diagnost VM, and GE Revolution XR/d. These results were confirmed by the ratio of IeDQE and IDQE in the same conditions. Conclusions: The authors confirm the robustness and reproducibility of the eDQE method. As expected, the DR systems

  11. Radiography of scoliosis: comparative dosimetry between conventional technique and digital fluorography; Radiographie des scolioses: dosimetrie comparee entre la technique conventionnelle et la fluorographie numerique

    Energy Technology Data Exchange (ETDEWEB)

    Gorincour, G.; Paris, M.; Aschero, A.; Bourliere, B.; Devred, P.; Petit, P. [Hopital Timone-Enfants, Service de Radiologie Pediatrique, 13 - Marseille (France); Barrau, K.; Auquier, P. [Faculte de Medecine de Marseille, Service de Sante Publique, 13 - Marseille (France); Waultier, S.; Bourrelly, M.; Mundler, O. [Hopital Timone-Enfants, Service de Medecine Nucleaire, 13 - Marseille (France); Viehweger, E.; Jouve, J.L.; Bollini, G. [Hopital Timone-Enfants, Service de Chirurgie Orthopedique, 13 - Marseille (France)

    2007-03-15

    Objective. Compare the irradiation delivered in conventional radiography and digital radiography by image intensifier during a scoliosis workup. Patients and Methods. Our prospective randomized study included 105 patients, all of whom were identified according to socio-demographic parameters as well as criteria evaluating the quality of the full front spinal x-ray at PA incidence. The entry dose at the scapula and the exit dose in inter-orbital, thyroid, mammary, and hypo-gastric projection was measured by thermoluminescent dosimeters. Results. The results of 71 girls and 28 boys, aged a mean 13.8 years with a mean weight of 47 kg were analyzed. At equal image quality, the entry dose was not significantly different between the two techniques; the mean exit dose reduction was 64% during digital acquisition. This reduction involved the inter-orbital (162%), mammary (43%), and thyroid (309%) regions. However, this system is more irradiating in the hypo-gastric region (34%). Conclusion. The dosimetric evaluation of the different imaging techniques used to explore the entirety of the spine should be part of radiologists' quality standard used to document their work and their choices. (authors)

  12. Small animals bone density and morphometry analysis with a dual energy X-rays absorptiometry bone densitometer using a 2D digital radiographic detector; Analyse de la densite osseuse et de la morphometrie de petits animaux avec un osteodensitometre bi-energie utilisant un capteur 2D de radiographie numerique

    Energy Technology Data Exchange (ETDEWEB)

    Boudousq, V. [Centre Hospitalier Universitaire de Nimes, 30 (France); Bordy, T.; Gonon, G.; Dinten, J.M. [CEA Grenoble (DTBS/STD), Lab. d' Electronique et de Technologie de l' Informatique, LETI, 38 (France)

    2004-07-01

    LEXXOS (DMS, Montpellier, France) is the first axial and total body cone beam bone densitometer using a 2D digital radiographic detector. In previous papers, technical principles and patients' Bone Mineral Density (BMD) measurement performances were presented. Bone densitometers are also used on small animals for drug development. In this presentation, we show how LEXXOS can be adapted for small animals' examinations and evaluate its performances. At first, in order to take advantage of the whole area of the 20 x 20 cm{sup 2} digital radiographic detector, it has been made profit of X-Rays magnification by adapting the geometrical configuration. Secondly, as small animals present low BMD, a specific dual energy calibration has been defined. This adapted system has then been evaluated on two sets of mice: six reference mice and six ovariectomized mice. Each month, these two populations have been examined and the averaged total body BMD has been measured. This evaluation shows that the right order of BMD magnitude is obtained and, as expected, BMD increases on two sets until a period around puberty and the ovariectomized set presents a significant decrease after. Moreover, the bone image obtained by dual energy processing on LEXXOS presents a radiographic image quality providing useful complementary information on bone morphometry and architecture. This study shows that LEXXOS cone beam bone densitometer provides simultaneously useful quantitative and qualitative information for analysis of bone evolution on small animals. In the future, same system architecture and processing methodology can be used with higher resolution detectors in order to refine information on bone architecture. (authors)

  13. Low contrast detectability and dose savings with an amorphous silicon detector designed for x-ray radiography

    Science.gov (United States)

    Xue, Ping; Schubert, Scott F.; Aufrichtig, Richard

    2000-04-01

    In an observer study we compare low contrast detectability and dose efficiency of an amorphous silicon x-ray detector versus a standard thoracic screen-film (Kodak InSight HC/InSight IT). Twelve images of a CDRAD contrast-detail phantom were acquired with the screen-film system using an entrance exposure corresponding to a conventional chest x-ray. Using the same x- ray system with an interchanged digital detector, we acquired four digital image sets (12 images each) at dose levels corresponding to 27%, 41%, 63% and 100% of the film dose. Prior to laser printing, the digital images were processed to match the film contrast and optical density level. A 4- alternative forced choice (4-AFC) paradigm with seven observers was used to measure the threshold contrasts of disk sizes from 0.5 to 4.0 mm. Further, we estimated the equivalent perceptual dose (EPD), which is the dose level of digital for which the same contrast detectability as film is obtained. Contrast detectability is significantly improved with the digital detector. On average, all disk shaped objects detected from the digital detector have lower threshold contrasts than those from film at the same dose level. The EPD value averaged over disk size is 44%, which corresponds to a 56% dose savings for the digital detector.

  14. A software tool for quality assurance of computed/digital radiography (CR/DR) systems

    Science.gov (United States)

    Desai, Nikunj; Valentino, Daniel J.

    2011-03-01

    The recommended methods to test the performance of computed radiography (CR) systems have been established by The American Association of Physicists in Medicine, Report No. 93, "Acceptance Testing and Quality Control of Photostimulable Storage Phosphor Imaging Systems". The quality assurance tests are categorized by how frequently they need to be performed. Quality assurance of CR systems is the responsibility of the facility that performs the exam and is governed by the state in which the facility is located. For Example, the New York State Department of Health has established a guide which lists the tests that a CR facility must perform for quality assurance. This study aims at educating the reader about the new quality assurance requirements defined by the state. It further demonstrates an easy to use software tool, henceforth referred to as the Digital Physicist, developed to aid a radiologic facility in conforming with state guidelines and monitoring quality assurance of CR/DR imaging systems. The Digital Physicist provides a vendor independent procedure for quality assurance of CR/DR systems. Further it, generates a PDF report with a brief description of these tests and the obtained results.

  15. Digital radiography of scoliosis with a scanning method: radiation dose optimization

    Energy Technology Data Exchange (ETDEWEB)

    Geijer, Haakan; Andersson, Torbjoern [Department of Radiology, Oerebro University Hospital, 701 85 Oerebro (Sweden); Verdonck, Bert [Philips Medical Systems, P.O. Box 10,000, 5680 Best (Netherlands); Beckman, Karl-Wilhelm; Persliden, Jan [Department of Medical Physics, Oerebro University Hospital, 701 85 Oerebro (Sweden)

    2003-03-01

    The aim of this study was optimization of the radiation dose-image quality relationship for a digital scanning method of scoliosis radiography. The examination is performed as a digital multi-image translation scan that is reconstructed to a single image in a workstation. Entrance dose was recorded with thermoluminescent dosimeters placed dorsally on an Alderson phantom. At the same time, kerma area product (KAP) values were recorded. A Monte Carlo calculation of effective dose was also made. Image quality was evaluated with a contrast-detail phantom and Visual Grading. The radiation dose was reduced by lowering the image intensifier entrance dose request, adjusting pulse frequency and scan speed, and by raising tube voltage. The calculated effective dose was reduced from 0.15 to 0.05 mSv with reduction of KAP from 1.07 to 0.25 Gy cm{sup 2} and entrance dose from 0.90 to 0.21 mGy. The image quality was reduced with the Image Quality Figure going from 52 to 62 and a corresponding reduction in image quality as assessed with Visual Grading. The optimization resulted in a dose reduction to 31% of the original effective dose with an acceptable reduction in image quality considering the intended use of the images for angle measurements. (orig.)

  16. Benchmarking the performance of fixed-image receptor digital radiography systems. Part 2: system performance metric.

    Science.gov (United States)

    Lee, Kam L; Bernardo, Michael; Ireland, Timothy A

    2016-06-01

    This is part two of a two-part study in benchmarking system performance of fixed digital radiographic systems. The study compares the system performance of seven fixed digital radiography systems based on quantitative metrics like modulation transfer function (sMTF), normalised noise power spectrum (sNNPS), detective quantum efficiency (sDQE) and entrance surface air kerma (ESAK). It was found that the most efficient image receptors (greatest sDQE) were not necessarily operating at the lowest ESAK. In part one of this study, sMTF is shown to depend on system configuration while sNNPS is shown to be relatively consistent across systems. Systems are ranked on their signal-to-noise ratio efficiency (sDQE) and their ESAK. Systems using the same equipment configuration do not necessarily have the same system performance. This implies radiographic practice at the site will have an impact on the overall system performance. In general, systems are more dose efficient at low dose settings.

  17. Suppression of the low spatial frequency effects of scattered radiation in digital radiography

    Science.gov (United States)

    Kotre, C. J.

    2016-01-01

    One of the deleterious effects of scattered radiation in the digital radiograph is to add a slowly varying background to the image. This can reduce the ability of the observer to discern low contrast signals if the background gradient over a signal feature prevents the use of a small enough display window to make the signal visible. This paper presents an image processing scheme for suppressing the low spatial frequency effects of scattered radiation in digital radiography and demonstrates it on a range of clinical and phantom images. The approach relies on the approximate separation of high atomic number bony features from the low atomic number soft tissue background, and the use of forward convolution with a scatter kernel to produce an estimate of the scatter distribution arising from the soft tissue background. This is then scaled by an estimate of the soft tissue scatter fraction and subtracted from the original image to produce the final scatter-suppressed image. The implementation employs many approximations in order to make use of information that is readily available in the image headers of current x-ray imaging systems. The performance of the image processing scheme is demonstrated on phantom and clinical images. It is argued that clinical application of the approach could employ a user-controlled scatter subtraction step that would reduce any risk of misinterpretation of the processed image.

  18. Analysis of the reproducibility of the gray values and noise of a direct digital radiography system

    Directory of Open Access Journals (Sweden)

    Marcelo Lupion POLETI

    2015-01-01

    Full Text Available The aim of this study was to evaluate the reproducibility of the gray values and noise of a direct digital radiography system (Visualix eHD for various exposure times and analyzed regions. To obtain radiographic images in a standardized manner, the digital sensor of the system and a stepwedge were positioned in a phantom at a focus-film distance of 30 cm in a dental device at 70 kV, 7 mA and 2.2 mm filtration. Ten consecutive repetitions of X-ray imaging were performed at each exposure time (0.05, 0.07, 0.09 and 0.13 s. Gray values were analyzed using ImageJ software in five regions of interest (ROIs: alveolar bone (AB, soft tissue (ST and three steps of the stepwedge (S1, S2 and S3. The results showed that both the variability of the gray values and the noise were statistically greater (p < 0.05 in the most radiolucent region (ST. Only the noise was affected by the exposure time. In conclusion, the reproducibility of the gray values and the noise of the Visualix eHD system can vary in specific areas with different radiolucency.

  19. Increasing mobile radiography productivity.

    Science.gov (United States)

    Wong, Edward; Lung, Ngan Tsz; Ng, Kris; Jeor, Patrick

    2013-01-01

    Mobile radiography using computed radiography (CR) cassettes is a common equipment combination with a workflow bottleneck limited by location of CR readers. Advent of direct digital radiography (DDR) mobile x-ray machines removes this limitation by immediate image review and quality control. Through the use of key performance indicators (KPIs), the increase in efficiency can be quantified.

  20. Evaluation of Radiopacity of Bulk-fill Flowable Composites Using Digital Radiography.

    Science.gov (United States)

    Tarcin, B; Gumru, B; Peker, S; Ovecoglu, H S

    2016-01-01

    New flowable composites that may be bulk-filled in layers up to 4 mm are indicated as a base beneath posterior composite restorations. Sufficient radiopacity is one of the several important requirements such materials should meet. The aim of this study was to evaluate the radiopacity of bulk-fill flowable composites and to provide a comparison with conventional flowable composites using digital imaging. Ten standard specimens (5 mm in diameter, 1 mm in thickness) were prepared from each of four different bulk-fill flowable composites and nine different conventional flowable composites. Radiographs of the specimens were taken together with 1-mm-thick tooth slices and an aluminum step wedge using a digital imaging system. For the radiographic exposures, a storage phosphor plate and a dental x-ray unit at 70 kVp and 8 mA were used. The object-to-focus distance was 30 cm, and the exposure time was 0.2 seconds. The gray values of the materials were measured using the histogram function of the software available with the system, and radiopacity was calculated as the equivalent thickness of aluminum. The data were analyzed statistically (pflowable composites showed significantly higher radiopacity values in comparison with those of enamel, dentin, and most of the conventional flowable composites (pflowable composites was as follows: Venus Bulk Fill (Heraeus Kulzer) ≥ X-tra Base (Voco) > SDR (Dentsply DeTrey) ≥ Filtek Bulk Fill (3M ESPE). To conclude, the bulk-fill flowable restorative materials, which were tested in this study using digital radiography, met the minimum standard of radiopacity specified by the International Standards Organization.

  1. Performance of digital radiography with enhancement filters for the diagnosis of proximal caries

    Directory of Open Access Journals (Sweden)

    Manuella Dias Furtado Belém

    2013-06-01

    Full Text Available Enhancement filters are potentially supposed to improve the diagnostic performance of digital images. Thus, the aim of this study was to compare the performance of digital radiography with and without enhancement filters for the detection of induced proximal caries lesions. The total sample consisted of 120 sound human teeth (40 premolars, 80 molars. Enamel subsurface demineralization was induced in one of the proximal surfaces of 60 teeth. Standardized radiographs of all teeth were acquired after the demineralization phase using the Digora-Optime® system. Four radiologists examined the digital radiographs and applied the following filters provided by the Digora® for Windows 2.6 package: Negative, Sharpen and both (Negative plus Sharpen. Validation of radiographic diagnosis was carried out by Knoop cross-sectional micro-hardness profiling on the proximal surfaces. Intraobserver agreement was estimated using Kappa statistics (k. Sensitivity, specificity and over-all accuracy were compared using ANOVA/Tukey test (α = 5%. Intraobserver agreement ranged from good to very good/optimal (k: 0.65–0.83. Although not statistically significant, the highest sensitivity (0.68 ± 0.22 and accuracy (0.76 ± 0.16 values were observed using the Sharpen filter as opposed to the Negative filter, which presented the lowest performance indices (0.57 ± 0.13 and 0.70 ± 0.10, respectively. Specificity ranged from 0.84 to 0.85, considering all imaging modalities (p > 0.05. Insofar as the Sharpen filter had the highest performance indices, it may be considered a useful adjunct for detecting subtle proximal caries lesions.

  2. Pulmonary nodule detection with digital projection radiography: an ex-vivo study on increased latitude post-processing.

    Science.gov (United States)

    Biederer, Juergen; Gottwald, Tobias; Bolte, Hendrik; Riedel, Christian; Freitag, Sandra; Van Metter, Richard; Heller, Martin

    2007-04-01

    To evaluate increased image latitude post-processing of digital projection radiograms for the detection of pulmonary nodules. 20 porcine lungs were inflated inside a chest phantom, prepared with 280 solid nodules of 4-8 mm in diameter and examined with direct radiography (3.0x2.5 k detector, 125 kVp, 4 mAs). Nodule position and size were documented by CT controls and dissection. Four intact lungs served as negative controls. Image post-processing included standard tone scales and increased latitude with detail contrast enhancement (log-factors 1.0, 1.5 and 2.0). 1280 sub-images (512x512 pixel) were centred on nodules or controls, behind the diaphragm and over free parenchyma, randomized and presented to six readers. Confidence in the decision was recorded with a scale of 0-100%. Sensitivity and specificity for nodules behind the diaphragm were 0.87/0.97 at standard tone scale and 0.92/0.92 with increased latitude (log factor 2.0). The fraction of "not diagnostic" readings was reduced (from 208/1920 to 52/1920). As an indicator of increased detection confidence, the median of the ratings behind the diaphragm approached 100 and 0, respectively, and the inter-quartile width decreased (controls: pimage latitude. Above the diaphragm, accuracy and detection confidence remained unchanged. Here, the sensitivity for nodules was 0.94 with a specificity from 0.96 to 0.97 (all p>0.05). Increased latitude post-processing has minimal effects on the overall accuracy, but improves the detection confidence for sub-centimeter nodules in the posterior recesses of the lung.

  3. Characterisation of Late Bronze Age large size shield nails by EDXRF, micro-EDXRF and X-ray digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Figueiredo, E., E-mail: elin@itn.pt [Instituto Tecnologico e Nuclear, Estrada Nacional 10, 2686-953 Sacavem (Portugal); CENIMAT/I3N, Departamento de Ciencia dos Materiais, Faculdade de Ciencias e Tecnologia, Universidade Nova de Lisboa, 2829-516 Monte de Caparica (Portugal); Departamento de Conservacao e Restauro, Faculdade de Ciencias e Tecnologia, Universidade Nova de Lisboa, 2829-516 Monte de Caparica (Portugal); Araujo, M.F. [Instituto Tecnologico e Nuclear, Estrada Nacional 10, 2686-953 Sacavem (Portugal); Silva, R.J.C. [CENIMAT/I3N, Departamento de Ciencia dos Materiais, Faculdade de Ciencias e Tecnologia, Universidade Nova de Lisboa, 2829-516 Monte de Caparica (Portugal); Senna-Martinez, J.C. [Centro de Arqueologia (Uniarq), Faculdade de Letras, Universidade de Lisboa, 1600-214 Lisboa (Portugal); Ines Vaz, J.L. [Departamento de Letras, Universidade Catolica, Estrada da Circunvalacao, 3504-505 Viseu (Portugal)

    2011-09-15

    In the present study six exceptional large size metallic nails, a dagger and a sickle from the Late Bronze Age archaeological site of Figueiredo das Donas (Central Portugal) have been analysed by EDXRF, micro-EDXRF and X-ray digital radiography for the study of material composition and technology of fabrication. The combination of these analytical and examination techniques showed that all artefacts are made of bronze with As, Sb and Pb impurities, and that the nails were most likely manufactured using the casting-on technique. These results reinforce the use of binary bronze by Late Bronze Age in the region, and the incorporation of new fabrication technologies that resulted from ancient spheres of interaction. - Highlights: > EDXRF, micro-EDXRF and X-ray digital radiography in cultural heritage studies. > Archaeometallurgical study of a Late Bronze Age artefact collection from Portugal. > Practise of a specific and traditional bronze metallurgy. > Appearance of technological innovations as the casting-on technique.

  4. [Physical image properties of digital radiography systems in low dose range].

    Science.gov (United States)

    Kunitomo, Hiroshi; Ichikawa, Katsuhiro; Higashide, Ryo; Ohashi, Kazuya

    2012-01-01

    We measured physical image properties of a flat panel detector (FPD) system and a computed radiography (CR) system, targeting to a low dose range (reference dose: 2.58×10(-7) C/kg: to 1/20 dose). Input-output properties, pre-sampled modulation transfer functions (pre-sampled MTFs), and normalized noise power spectra for an FPD system equipped with a CsI scintillator (FPDcsi) and a CR system with an imaging plate coated with storage phosphor (CR) were measured at the low dose range for radiation quality of RQA3 (≍50 skV) and RQA5 (≍70 kV), and detective quantum efficiencies (DQEs) were calculated. In addition, in order to validate the DQE results, component fractions of Poisson and multiplicative and additive noise were analyzed using relative standard deviation analysis. The DQE values of FPDcsi were decreased with dose decrease, and contrarily to these, those of CR were increased. At the 1/10 and 1/20 doses for RQA3, the DQEs of FPDcsi and CR became almost the same. From the results of RSD analysis, it was proved that the main cause of DQE deterioration on FPDcsi are non-negligible additive (electronic) noise, and the DQE improvement on CR was caused by both of significant multiplicative (structure) noise and very low electronic noise. The DQE results were validated by comparing burger phantom images of each dose and radiation quality.

  5. Neutron radiography as a non-destructive method for diagnosing neutron converters for advanced thermal neutron detectors

    Science.gov (United States)

    Muraro, A.; Albani, G.; Perelli Cippo, E.; Croci, G.; Angella, G.; Birch, J.; Cazzaniga, C.; Caniello, R.; Dell'Era, F.; Ghezzi, F.; Grosso, G.; Hall-Wilton, R.; Höglund, C.; Hultman, L.; Schimdt, S.; Robinson, L.; Rebai, M.; Salvato, G.; Tresoldi, D.; Vasi, C.; Tardocchi, M.

    2016-03-01

    Due to the well-known problem of 3He shortage, a series of different thermal neutron detectors alternative to helium tubes are being developed, with the goal to find valid candidates for detection systems for the future spallation neutron sources such as the European Spallation Source (ESS). A possible 3He-free detector candidate is a charged particle detector equipped with a three dimensional neutron converter cathode (3D-C). The 3D-C currently under development is composed by a series of alumina (Al2O3) lamellas coated by 1 μ m of 10B enriched boron carbide (B4C). In order to obtain a good characterization in terms of detector efficiency and uniformity it is crucial to know the thickness, the uniformity and the atomic composition of the B4C neutron converter coating. In this work a non-destructive technique for the characterization of the lamellas that will compose the 3D-C was performed using neutron radiography. The results of these measurements show that the lamellas that will be used have coating uniformity suitable for detector applications. This technique (compared with SEM, EDX, ERDA, XPS) has the advantage of being global (i.e. non point-like) and non-destructive, thus it is suitable as a check method for mass production of the 3D-C elements.

  6. Fusion of multi-voltage digital radiography images based on nonsubsampled contourlet transform.

    Science.gov (United States)

    Yanjie, Qi; Liming, Wang

    2016-01-01

    In order to increase the single digital radiography (DR) image information of the composite component in the industry, the different DR images are captured at different voltages so as to get the structural information at different thickness region firstly. Secondly, the original DR images are decomposed by nonsubsampled contourlet transform (NSCT), and the low-frequency subbands are fused by the role of principle component analysis (PCA), and the modified central energy role is used to carry out the high-frequency directional subbands fusion. The false edges are extracted, and the values of the high-frequency subband coefficients of the false edges are set to be a small value so as to reduce the false edges in the fusion image. Finally, the output image can be obtained by inverse nonsubsampled contourlet transform. The experimental results show that the fused DR image brings more detailed information, and the structure of the component can be seen clearly, so it is useful to the fast and accurate quality judgements of the component.

  7. Quantitative digital subtraction radiography for assessment of bone density changes following periodontal guided tissue regeneration.

    Science.gov (United States)

    Christgau, M; Wenzel, A; Hiller, K A; Schmalz, G

    1996-01-01

    The quantitative assessment of alveolar bone density changes in periodontal defects following guided tissue regeneration (GTR). Twelve patients with 30 intrabony lesions and 16 furcation defects took part. Standardized radiographic and clinical examinations were carried out immediately before and then 5 and 13 months after surgery. Intra-oral radiographs were evaluated by means of digital subtraction radiography (DSR). Within the subtraction images, a window ('experimental region') was defined covering the visible density changes in the defect area. Background noise was measured by using a similarly sized window ('control region') located in an area not affected by GTR. Bone density changes were quantitatively evaluated by calculation of the mean, standard deviation and maximum and minimum values of the grey-level histogram within these windows. DSR revealed significant bone density gain after GTR in intrabony and furcation defects. While a continuous increase was observed over the 13 month period in intrabony defects, changes in furcation defects occurred mostly in the 5-13 month period. Clinically, a distinct vertical and horizontal attachment gain was found. The correlation coefficients between changes in radiographic density and clinical parameters were low, indicating a difference in the information obtained by the two diagnostic methods. Quantitative DSR is a valuable, non-invasive, objective method to obtain information on density changes in intrabony and furcation defects treated by GTR. However, a full assessment of soft and hard tissue changes requires both clinical evaluation and DSR.

  8. Effectiveness of digital subtraction radiography in detecting artificially created osteophytes and erosions in the temporomandibular joint

    Energy Technology Data Exchange (ETDEWEB)

    Kocasarac, Husniye Demirturk [Dept. of Comprehensive Dentistry, The University of Texas Health Science Center, San Antonio (United States); Celenk, Peruze [Dept. of Oral and Maxillofacial Radiology, Faculty of Dentistry, Ondokuz Mayis University, Samsun (Turkmenistan)

    2017-06-15

    Erosions and osteophytes are radiographic characteristics that are found in different stages of temporomandibular joint (TMJ) osteoarthritis. This study assessed the effectiveness of digital subtraction radiography (DSR) in diagnosing simulated osteophytes and erosions in the TMJ. Five intact, dry human skulls were used to assess the effectiveness of DSR in detecting osteophytes. Four cortical bone chips of varying thicknesses (0.5 mm, 1.0 mm, 1.5 mm, and 2.0 mm) were placed at the medial, central, and lateral aspects of the condyle anterior surface. Two defects of varying depth (1.0 mm and 1.5 mm) were created on the lateral, central, and medial poles of the condyles of 2 skulls to simulate erosions. Panoramic images of the condyles were acquired before and after artificially creating the changes. Digital subtraction was performed with Emago dental image archiving software. Five observers familiar with the interpretation of TMJ radiographs evaluated the images. Receiver operating characteristic (ROC) analysis was used to evaluate the diagnostic accuracy of the imaging methods. The area under the ROC curve (Az) value for the overall diagnostic accuracy of DSR in detecting osteophytic changes was 0.931. The Az value for the overall diagnostic accuracy of panoramic imaging was 0.695. The accuracy of DSR in detecting erosive changes was 0.854 and 0.696 for panoramic imaging. DSR was remarkably more accurate than panoramic imaging in detecting simulated osteophytic and erosive changes. The accuracy of panoramic imaging in detecting degenerative changes was significantly lower than the accuracy of DSR (P<.05). DSR improved the accuracy of detection using panoramic images.

  9. Free software for performing physical analysis of systems for digital radiography and mammography

    Energy Technology Data Exchange (ETDEWEB)

    Donini, Bruno; Lanconelli, Nico, E-mail: nico.lanconelli@unibo.it [Alma Mater Studiorum, Department of Physics and Astronomy, University of Bologna, Bologna 40127 (Italy); Rivetti, Stefano [Fisica Medica, Ospedale di Sassuolo S.p.A., Sassuolo 41049 (Italy); Bertolini, Marco [Medical Physics Unit, Azienda Ospedaliera ASMN, Istituto di Ricovero e Cura a Carattere Scientifico, Reggio Emilia 42123 (Italy)

    2014-05-15

    Purpose: In this paper, the authors present a free software for assisting users in achieving the physical characterization of x-ray digital systems and image quality checks. Methods: The program was developed as a plugin of a well-known public-domain suite ImageJ. The software can assist users in calculating various physical parameters such as the response curve (also termed signal transfer property), modulation transfer function (MTF), noise power spectra (NPS), and detective quantum efficiency (DQE). It also includes the computation of some image quality checks: defective pixel analysis, uniformity, dark analysis, and lag. Results: The software was made available in 2009 and has been used during the last couple of years by many users who gave us valuable feedback for improving its usability. It was tested for achieving the physical characterization of several clinical systems for digital radiography and mammography. Various published papers made use of the outcomes of the plugin. Conclusions: This software is potentially beneficial to a variety of users: physicists working in hospitals, staff working in radiological departments, such as medical physicists, physicians, engineers. The plugin, together with a brief user manual, are freely available and can be found online ( http://www.medphys.it/downloads.htm ). With our plugin users can estimate all three most important parameters used for physical characterization (MTF, NPS, and also DQE). The plugin can run on any operating system equipped with ImageJ suite. The authors validated the software by comparing MTF and NPS curves on a common set of images with those obtained with other dedicated programs, achieving a very good agreement.

  10. Development of ionizing radiations dosimetry by plastic detectors and films of radiography; Desenvolvimento de dosimetria de radiacoes ionizantes por detectores plasticos e filmes de radiografia

    Energy Technology Data Exchange (ETDEWEB)

    Levit, Vladimir; Santos, Ari S.; Louzada, Ana R.; Silveira, Cristina M.; Vaniel, Ana P. [Pelotas Univ., RS (Brazil). Inst. de Quimica e Geociencias]. E-mail: vlevit@ufpel.tche.br; Fedorov, Dmitri [Instituto Nacional de Pesquisas Espaciais (INPE), Sao Jose dos Campos, SP (Brazil)]. E-mail: fedorov@nucleo.inpe.br

    2000-07-01

    This work shows the development of an automatic and computerized system for detection and analysis of the ionizing radiation trace in solid detectors and one of the signals of this irradiation in radiography films with the main goal of improve the ionizing radiation detection methods. On the development of this method it was used a calibration source of {sup 252}Cf, which is a radionuclide with alpha decay and spontaneous fission and, by this reason, irradiates {alpha} and {gamma} particles and nuclear fragments. Solid detectors of makrofol ware used for the nuclear fragments and radiography films ware used for the detection of {alpha} and {gamma} particles. Those signals images reveled of the {alpha} and {gamma} particles and of the nuclear fragments traces ware analysed on a microscopy and recorded on computers. The computer system developed allows to capture those images from the microscope as computer files, the identification of nuclear fragments traces and the {alpha} and {gamma} particles signals and the separation of the objects of interest to do the counting and analysis of the size and the shape of those traces.

  11. Focal spot measurements using a digital flat panel detector

    Science.gov (United States)

    Jain, Amit; Panse, A.; Bednarek, Daniel R.; Rudin, Stephen

    2014-03-01

    Focal spot size is one of the crucial factors that affect the image quality of any x-ray imaging system. It is, therefore, important to measure the focal spot size accurately. In the past, pinhole and slit measurements of x-ray focal spots were obtained using direct exposure film. At present, digital detectors are replacing film in medical imaging so that, although focal spot measurements can be made quickly with such detectors, one must be careful to account for the generally poorer spatial resolution of the detector and the limited usable magnification. For this study, the focal spots of a diagnostic x-ray tube were measured with a 10-μm pinhole using a 194-μm pixel flat panel detector (FPD). The twodimensional MTF, measured with the Noise Response (NR) Method was used for the correction for the detector blurring. The resulting focal spot sizes based on the FWTM (Full Width at Tenth Maxima) were compared with those obtained with a very high resolution detector with 8-μm pixels. This study demonstrates the possible effect of detector blurring on the focal spot size measurements with digital detectors with poor resolution and the improvement obtained by deconvolution. Additionally, using the NR method for measuring the two-dimensional MTF, any non-isotropies in detector resolution can be accurately corrected for, enabling routine measurement of non-isotropic x-ray focal spots. This work presents a simple, accurate and quick quality assurance procedure for measurements of both digital detector properties and x-ray focal spot size and distribution in modern x-ray imaging systems.

  12. Evaluation of conventional and digital radiography capacities for distinguishing dental materials on radiograms depending on the present radiopacifying agent

    Directory of Open Access Journals (Sweden)

    Antonijević Đorđe

    2014-01-01

    Full Text Available Bacgroun/Aim. The radiopacity of an endodontic material can considerably vary as measured on film and a digital sensor. Digital radiography offers numerous advantages over convential film-based radiography in dental clinical practice regarding both diagnostic capabilities and postintervention procedures. The aim of this study was to investigate the capacity of conventional and charge-conpled device (CCD based digital radiography to detect material on radiograph depending on the radio-pacifying agent present in the material. Methods. Experimental cements were formulated by mixing Portland cement with the following radiopacifying agents: zinc oxide (ZnO, zirconium oxide (ZrO2, titanium dioxide (TiO2, barium sulphate (BaSO4, iodoform (CHI3, bismuth oxide (Bi2O3 and ytterbium trifluoride (YbF3. In addition, 5 endodontic materials comprising Endomethasone®, Diaket®, N2®, Roth 801® and Acroseal® were investigated to serve as control. Per three specimens of each material were radiographed alongside an aluminum step wedge on film (Eastman Kodak Company®, Rochester, NY and a CCD-based digital sensor (Trophy Radiologie®, Cedex, France. Radiopacity values were calculated by converting the radiographic densities of the specimens expressed as a mean optical densities or mean grey scale values into equivalent thickness of aluminum. Results. Twoway ANOVA detected no significant differences with respect to the imaging system (p > 0.05, but the differences were significant with respect to radiopacifier (p < 0.001 and the interaction of the two factors (p < 0.05. Paired ttest revealed significant differences between the methods used for pure Portland cement, all concentrations of BaSO4 and CHI3, 10% and 20% additions of ZrO2 and Bi2O3 and 10% and 30% addition of YbF3 (p < 0.05. Conclusion. The materials which incorporate CHI3 or BaSO4 as radiopacifying agents are expected to be significantly more radiopaque on a digital sensor than on film. During clinical

  13. Evaluation of chronic periapical lesions by digital subtraction radiography by using Adobe Photoshop CS: a technical report.

    Science.gov (United States)

    Carvalho, Fabiola B; Gonçalves, Marcelo; Tanomaru-Filho, Mário

    2007-04-01

    The purpose of this study was to describe a new technique by using Adobe Photoshop CS (San Jose, CA) image-analysis software to evaluate the radiographic changes of chronic periapical lesions after root canal treatment by digital subtraction radiography. Thirteen upper anterior human teeth with pulp necrosis and radiographic image of chronic periapical lesion were endodontically treated and radiographed 0, 2, 4, and 6 months after root canal treatment by using a film holder. The radiographic films were automatically developed and digitized. The radiographic images taken 0, 2, 4, and 6 months after root canal therapy were submitted to digital subtraction in pairs (0 and 2 months, 2 and 4 months, and 4 and 6 months) choosing "image," "calculation," "subtract," and "new document" tools from Adobe Photoshop CS image-analysis software toolbar. The resulting images showed areas of periapical healing in all cases. According to this methodology, the healing or expansion of periapical lesions can be evaluated by means of digital subtraction radiography by using Adobe Photoshop CS software.

  14. Comparison of digital radiography and apex locator with the conventional method in root length determination of primary teeth

    Directory of Open Access Journals (Sweden)

    I E Neena

    2011-01-01

    Full Text Available Aim: The purpose of this study was to compare the Working length in primary teeth endodontics using intra oral digital radiovisiography and apex locator with conventional method for accuracy. Materials and Methods: This in vivo study was conducted on 30 primary teeth which were indicated for pulpectomy in the patients of the age group of 5-11 years All experimental teeth had adequate remaining tooth structure for rubber dam isolation and radiographicaly visible canals. Endodontic treatment was required due to irreversible pulpitis or pulp necrosis. A standardized intraoral periapical radiograph of the tooth was taken using conventional method by paralleling technique. The distance between the source and the tooth, tooth and the films were standardized using X-ray positioning device. During the pulpectomy procedure, the working length was determined by digital radiograph and apex locator. The measurements were then compared with the conventional method of root canal measurement technique for accuracy Result: From the results obtained we can conclude that Working length determined in primary molars using digital radiography and Apex locator did not show any significant difference in the mean working length measurements when compared with the conventional radiographic method. Conclusions: Apex locator is comparable to conventional radiograph in determining the working length without radiation in the primary teeth. Intraoral digital radiography is the safest method in determining the working length with significant reduction in radiation exposure.Hence, both the techniques can be safely used as alternatives to conventional radiographic methods in determining working length in primary teeth.

  15. Digital panoramic radiography for diagnosis of the temporomandibular joint: CBCT as the gold standard

    Directory of Open Access Journals (Sweden)

    Daniela Brait Silva LADEIRA

    2015-01-01

    Full Text Available Three-dimensional imaging modalities have been reported to be more accurate than panoramic radiographs (PR for the assessment of bone components of the temporomandibular joint (TMJ. No exact prior information is available that demonstrates which specific limitations occur in terms of TMJ diagnosis when using PR for this purpose. This study aimed to assess the clinical validity of digital panoramic radiography (DPR when diagnosing morphological disorders of the TMJ using cone-beam computed tomography (CBCT images as the gold standard. A sample composed of TMJ images (N = 848, including 212 DPR and 212 CBCT images obtained from the same patient, was used to assess any morphological changes in the TMJ. Four appraisers diagnosed all of the DPR images, whereas the CBCT images were used to establish the gold standard. The reliability of each appraiser’s response pattern was analyzed using the Kappa test (κ, and diagnostic tests were performed to assess each appraiser’s performance using a significance level setting of 5% (α = 0.05. Reliability of each appraiser’s response pattern compared to the gold standard ranged from a slight-to-moderate agreement (0.18 ≤ κ ≤ 0.45; and among the different appraisers, the response pattern showed a fair agreement (0.22 ≤ κ ≤ 0.39. Diagnostic tests showed a wide range among the different possible morphological changes diagnosed. DPR does not have validity when diagnosing morphological changes in the TMJ; it underestimates the radiological findings with higher prevalence, and thus, it cannot be used effectively as a diagnostic tool for bone components within this region.

  16. Local liquid velocity measurement of Trickle Bed Reactor using Digital Industrial X-ray Radiography

    Science.gov (United States)

    Mohd Salleh, Khairul Anuar

    Trickle Bed Reactors (TBRs) are fixed beds of particles in which both liquid and gas flow concurrently downward. They are widely used to produce not only fuels but also lubrication products. The measurement and the knowledge of local liquid velocities (VLL) in TBRs is less which is essential for advancing the understanding of its hydrodynamics and for validation computational fluid dynamics (CFD). Therefore, this work focused on developing a new, non-invasive, statistically reliable technique that can be used to measure local liquid velocity (VLL) in two-dimensions (2-D). This is performed by combining Digital Industrial X-ray Radiography (DIR) and Particle Tracking Velocimetry (PTV) techniques. This work also make possible the development of three-dimensional (3-D) VLL measurements that can be taken in TBRs. Measurements taken through both the combined and the novel technique, once validated, were found to be comparable to another technique (a two-point fiber optical probe) currently being developed at Missouri University of Science and Technology. The results from this study indicate that, for a gas-liquid-solid type bed, the measured VLL can have a maximum range that is between 35 and 51 times that of its superficial liquid velocity (VSL). Without the existence of gas, the measured VLL can have a maximum range that is between 4 and 4.7 times that of its VSL. At a higher V SL, the particle tracer was greatly distributed and became carried away by a high liquid flow rate. Neither the variance nor the range of measured VLL varied for any of the replications, confirming the reproducibility of the experimental measurements used, regardless of the VSL . The liquid's movement inside the pore was consistent with findings from previous studies that used various techniques.

  17. Digital panoramic radiography for diagnosis of the temporomandibular joint: CBCT as the gold standard.

    Science.gov (United States)

    Ladeira, Daniela Brait Silva; da Cruz, Adriana Dibo; de Almeida, Solange Maria

    2015-01-01

    Three-dimensional imaging modalities have been reported to be more accurate than panoramic radiographs (PR) for the assessment of bone components of the temporomandibular joint (TMJ). No exact prior information is available that demonstrates which specific limitations occur in terms of TMJ diagnosis when using PR for this purpose. This study aimed to assess the clinical validity of digital panoramic radiography (DPR) when diagnosing morphological disorders of the TMJ using cone-beam computed tomography (CBCT) images as the gold standard. A sample composed of TMJ images (N = 848), including 212 DPR and 212 CBCT images obtained from the same patient, was used to assess any morphological changes in the TMJ. Four appraisers diagnosed all of the DPR images, whereas the CBCT images were used to establish the gold standard. The reliability of each appraiser's response pattern was analyzed using the Kappa test (κ), and diagnostic tests were performed to assess each appraiser's performance using a significance level setting of 5% (α = 0.05). Reliability of each appraiser's response pattern compared to the gold standard ranged from a slight-to-moderate agreement (0.18 ≤ κ ≤ 0.45); and among the different appraisers, the response pattern showed a fair agreement (0.22 ≤ κ ≤ 0.39). Diagnostic tests showed a wide range among the different possible morphological changes diagnosed. DPR does not have validity when diagnosing morphological changes in the TMJ; it underestimates the radiological findings with higher prevalence, and thus, it cannot be used effectively as a diagnostic tool for bone components within this region.

  18. Digital Tomosynthesis for PNS Evaluation: Comparisons of Patient Exposure and Image Quality with Plain Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Myung Jin; Choi, Boram; Jung, Hye Na; Koo, Ji Hyun; Bae, Young A; Jeon, Kyeong Nam; Byun, Hong Sik; Lee, Kyung Soo [Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Yoo, Jin Young [Bundang Jesaeng General Hospital, Sungnam (Korea, Republic of)

    2012-03-15

    We investigated low dose digital tomosynthesis (DT) for the evaluation of the paranasal sinus (PNS), and compared its diagnostic accuracy with a PNS radiography series (XR). We enrolled 43 patients for whom XR, PNS DT, and OMU CT were performed. We measured effective doses (EDs) of XR, DT, and OMU CT using Monte Carlo simulation software. Two radiologists performed independent observation of both XR and DT. For seven PNSs, they scored anatomic conspicuity of sinuses and confidence on the presence of sinusitis using nine point scales. OMU CT was observed by the third radiologist and the findings were regarded as reference standard. We compared scores for conspicuity and sinusitis confidence between XR and DT. Mean EDs were 29 {+-} 6 {mu}Sv, 48 {+-} 10 {mu}Sv, and 980 {+-} 250 {mu}Sv, respectively, for XR, DT, and CT. Mean scores for conspicuity were 6.3 and 7.4, respectively, for XR and DT. Sensitivity per patient basis for sinusitis detection were 52% and 96%, respectively, for XR and DT in observer 1 (p = 0.001) and 80% and 92% for observer 2 (p = 0.25). Specificities for sinusitis exclusion were 100% for both XR and DT for observer 1 and 89% and 100% for observer 2 (p = 0.50). Accuracies for sinusitis diagnosis were 72% and 98%, respectively, for XR and DT for observer 1 (p = 0.001) and 84% and 95% for observer 2 (p = 0.125). Patient radiation dose from low dose DT is comparable with that of PNS XR. Diagnostic sensitivity of DT for sinusitis was superior to PNS XR.

  19. Nilai Radiometrik Direct Digital Intraoral Radiography (DDIDR Kualitas Tulang Rahang Mandibula

    Directory of Open Access Journals (Sweden)

    Hanna H. Bachtiar Iskandar

    2015-09-01

    Full Text Available Complete diagnosis in dentistry needs more detail and accurate quantitative as well as qualitative jawbone trabeculation evaluation. This requires modern diagnostic radiography that in Indonesia are still very limited. One form of the periodontitis that demands more attention and detailed information due to the great efforts to overcome, is Rapidly Progressive Periodontitis, and thus this disease has chosen as a model in this study. The objective of this study to get more detail and accurate radiometric of Direct Digital Intraoral value from grading Conventional value. This method expected to be a model of studies on jawbone quality in dentistry. The healting RPP patients as a subjects of this study. The methods trabeculation density from mandibular DDIR and conventional periapical radiographs of 116 healthy subjects and 41 RPP patients were evaluated and correlated to obtain transformation formula in the form of regression function. This study was performed Clinic of Dental Radiology and Periodontology, Faculty of Dentistry, University of Indonesia function were then used as a method to obtain quantitative data from conventional radiographs available. The results were indicated a significant independent variables were included in the regression function (p<0.05. Therefore even no DDIR equipment available, this transformation enable dentists all over Indonesia with only conventional radiographs available, to obtain more detail quantitative trabeculation density data. The conclusion is apart from getting a methode to transform conventional radiographic data into radiometric data equal to data obtained from DDR that more detail and accurate, this study also provides the normal radiographic trabeculation density value of peron 20 – 40 years as data base for further studies.

  20. Pulsed X-ray radiography of a gas jet target for laser-matter interaction experiments with the use of a CCD detector

    Energy Technology Data Exchange (ETDEWEB)

    Rakowski, R. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Bartnik, A. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Fiedorowicz, H. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland)]. E-mail: hfiedorowicz@wat.edu.pl; Jarocki, R. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Kostecki, J. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); MikoIajczyk, J. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Szczurek, A. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Szczurek, M. [Institute of Optoelectronics, Military University of Technology, 2 Kaliskiego Street, 00-908 Warsaw (Poland); Foeldes, I.B. [KFKI-Research Institute for Particle and Nuclear Physics, Association EURATOM, P.O. Box 49, H-1525 Budapest (Hungary); Toth, Zs. [Department of Optics and Quantum Electronics, University of Szeged, H-6701 Szeged, Pf.: 406 (Hungary)

    2005-10-01

    Characterization of gas jet targets has been carried out using pulsed X-ray radiography. A laser-plasma X-ray source was applied for backlighting of the targets to obtain X-ray shadowgraphs registered with a CCD detector. From the shadowgraphs, characteristics of the targets were determined.

  1. Accuracy of Cone Beam Computed Tomography, Photostimulable Phosphor Plate Digital Radiography and Conventional Radiography for Detection of Artificial Cancellous Bone Defects

    Directory of Open Access Journals (Sweden)

    Roghieh Bardal Bardal

    2016-08-01

    Full Text Available Objectives: The optimal goal of radiography is to provide high-quality diagnostic images with the least patient radiation dose. The aim of this study was to evaluate the accuracy of cone-beam computed tomography (CBCT and intraoral photostimulable phosphor plate (PSP digital and film-based conventional radiography for detection of artificial cancellous bone defects.Materials and Methods: Five dry human mandibles were used in this study. The mandibles were placed inside a water bath made of plexiglass plates; then PSP and CBCT scans were obtained. The mandibles were cut by a coping saw in buccolingual dimension and oval defects measuring 6.1×6.1 mm, 3×6.1 mm and 4×4 mm were created by a milling machine in the spongy bone. After fixing the two parts together (buccal and lingual, radiographs were repeated. Presence or absence of defects on images was evaluated and recorded by the two observers. Using SPSS 16, compatibility level, sensitivity, specificity and receiver operating curve (ROC analysis were determined for each observer.Results: The intraobserver agreement in all three imaging modalities was low to moderate (kappa≤0.613. The inter-observer agreement in all the three imaging modalities was moderate (kappa=0.406. The area under the curve (AUC of the imaging modalities in each observation was not significantly different. The area under the curve based on defect size for the two observers was not significantly different either.Conclusion: Defects confined to spongy bone can be identified on film and PSP radiographs and CBCT scans. However, interpretation of PSP images and CBCT scans needs greater expertise and skills.

  2. Use of semiconductor detector c-Si microstrip type in obtaining the digital radiographic imaging of phantoms and biological samples of mammary glands; Empleo de detector semiconductor de c-Si del tipo microbandas en la obtencion de imagenes radiograficas digitales de maniquies y muestras biologicas de mamas

    Energy Technology Data Exchange (ETDEWEB)

    Leyva, A.; Cabal, A.; Pinera, I.; Abreu, Y.; Cruz, C. M. [Centro de Estudios Avanzados y Desarrollo Nuclear, C. Habana, Cuba (Cuba); Montano, L. M.; Diaz, C. C.; Fontaine, M. [IPN, Centro de Investigaciones y Estudios Avanzados, Mexico D. F. (Mexico); Ortiz, C. M. [ISSSTE, Hospital General Tacuba, Clinica de Mama y Gineco-oncologia, Mexico D. F. (Mexico); Padilla, F. [Instituto Superior de Tecnologias y Ciencias Aplicadas, C. Habana, Cuba (Cuba); De la Mora, R. [Centro de Control Estatal de Equipos Medicos, C. Habana, Cuba (Cuba)], e-mail: aleyva@ceaden.edu.cu

    2009-07-01

    The present work synthesizes the experimental results obtained in the characterization of 64 micro strips crystalline silicon detector designed for experiments in high energies physics, with the objective of studying its possible application in advanced medical radiography, specifically in digital mammography and angiography. The research includes the acquisition of two-dimensional radiography of a mammography phantom using the scanning method, and its comparison with similar images simulated mathematically for different X rays sources. The paper also shows the experimental radiography of two biological samples taken from biopsies of mammas, where it is possible to identify the presence of possible pathological lesions. The results reached in this work point positively toward the effective possibility of satisfactorily introducing those advanced detectors in medical digital imaging applications. (Author)

  3. Megapixel digital InSb detector for midwave infrared imaging

    Science.gov (United States)

    Shkedy, Lior; Markovitz, Tuvy; Calahorra, Zipi; Hirsh, Itay; Shtrichman, Itay

    2011-06-01

    Since the late 1990s Semiconductor devices (SCDs) has developed and manufactured a variety of InSb two-dimensional (2D) focal plane arrays (FPAs) that were implemented in many infrared (IR) systems and applications. SCD routinely manufactures both analog and digital InSb FPAs with array formats of 320×256, 480×384, and 640×512 elements, and pitch size in the range 15 to 30 μm. These FPAs are available in many packaging configurations, including fully integrated detector-Dewar-cooler-assembly, with either closed-cycle Stirling or open-loop Joule-Thomson coolers. In response to a need for very high resolution midwave IR (MWIR) detectors and systems, SCD has developed a large format 2D InSb detector with 1280×1024 elements and pixel size of 15 μm. A digital readout integrated circuit (ROIC) is coupled by flip-chip bonding to the megapixel InSb array. The ROIC is fabricated in CMOS 0.18-μm technology, that enables the small pixel circuitry and relatively low power generation at the focal plane. The digital ROIC has an analog to digital (A/D) converter per-channel and allows for full frame readout at a rate of 100 Hz. Such on-chip A/D conversion eliminates the need for several A/D converters with fairly high power consumption at the system level. The digital readout, together with the InSb detector technology, lead to a wide linear dynamic range and low residual nonuniformity, which is stable over a long period of time following a nonuniformity correction procedure. A special Dewar was designed to withstand harsh environmental conditions while minimizing the contribution to the heat load of the detector. The Dewar together with the low power ROIC, enable a megapixel detector with overall low size, weight, and power with respect to comparable large format detectors. A variety of applications with this detector make use of different cold shields with different f-number and spectral filters. In this paper we present actual performance characteristics of the

  4. DR静态平板去除错层伪影的研究%Research on Elimination of Truncation Artifacts with Digital Radiography Static Flat Panel

    Institute of Scientific and Technical Information of China (English)

    王克枢

    2016-01-01

    This paper researched the occasional truncation artifacts during the application of Shimadzu D-vision digital radiography (DR) photographic system. Through analysis of features of abnormal image and design features of the DR equipment, the research found out that truncation artifacts were directly caused by premature movement of the flat panel detector. Based on the finding, the research proposed a resolution plan in which a flat panel detector delay return control circuit was added. Clinical results showed that the flat panel detector delay return control circuit integrated with D-vision DR photographic system could eliminate truncation artifacts caused by flat panel detector motion and improve DR image quality without decreasing examination efficiency, which allowed the design to be used in the improvement of related equipments.%本文对岛津D-vision平板摄影透视系统偶发的图像错层伪影现象进行了研究,通过对异常图像和设备自身设计特点进行分析,发现曝光后平板的过早运动是导致图像伪影的直接原因,基于此提出了加配平板延时返回控制电路的解决方案。改进后结果表明,在平板摄影透视系统加装平板延时返回功能后,图像错层现象消失,DR摄影图像质量得到提升,且改进不会影响检查效率,可应用推广至相关设备的改进。

  5. Micro-Radiography Using an Electron Linac Source and Ram Memory Chip Detectors

    Science.gov (United States)

    1990-06-01

    fr puNk elea;Otaw PONL J~ALLA~olU~fllde6 June 1990on (Izn ABSTRACT Radiography using a pulsed electron (LINAC) source and a semiconductor memory chip...a variety of shapes (circular holes, slits, etc.). The exceptional resolution of the system (owing to the extremely small size of individual bits in...Insights Inc. (5). These physical layouts appear in figs 1 and 2. It is from these layouts that an estimation of the pixel size for each device can

  6. Detection of urinary stones at reduced radiation exposure: a phantom study comparing computed radiography and a low-dose digital radiography linear slit scanning system

    Science.gov (United States)

    Szucs-Farkas, Zsolt; Chakraborty, D. P.; Thoeny, Harriet C.; Loupatatzis, Christos; Vock, Peter; Harald, Bonel

    2010-01-01

    Objective In this experimental study we assessed the diagnostic performance of linear slit scanning radiography (LSSR) compared to conventional computed radiography (CR) in the detection of urinary calculi in an anthropomorphic phantom imitating patients weighing approximately 58 to 88 kg. Conclusion Compared to computed radiography, LSSR is superior in the detection of urinary stones and may be used for pretreatment localization and follow-up at a lower patient exposure. PMID:19457787

  7. Digital pulse-shape processing for CdTe detectors

    CERN Document Server

    Bargholtz, C; Maartensson, L; Wachtmeister, S

    2001-01-01

    CdTe detectors suffer from low photo-peak efficiency and poor energy resolution. These problems are due to the drift properties of charge carriers in CdTe where particularly the holes have small mobility and trapping time. This is reflected in the amplitude and the shape of the detector output. To improve this situation a digital method is introduced where a sampling ADC is used to make a detailed measurement of the time evolution of the pulse. The measured pulse shape is fitted with a model. For the detector under study a model taking hole trapping into account significantly improves the photo-peak efficiency. The description of the hole component is, however, not fully satisfactory since for pulses with a large hole contribution a broadening of the full-energy peak occurs. Allowing for inhomogeneities in the detector material within the model partially remedies this deficiency.

  8. Digital RF phase detector for Linac in FEL accelerator

    Institute of Scientific and Technical Information of China (English)

    YU Lu-Yang; YIN Chong-Xian; LIU De-Kang

    2005-01-01

    The digital RF (Radio Frequency) phase detector based on commercial PXI (PCI eXtensions for Instrumentation) modules for the Linac is fully described in the paper. The DBM (Double Balance Mixer) is used as the phase detector and its control and data acquisition system is based on the PXI bus. The software adopts a curve fitting algorithm. The prototype has been tested in the laboratory and the good resolution, accuracy, reproducibility and reliability are expected. The system does not present the problems of analog solution.

  9. Extension of dynamic range in X-ray radiography using multi-color scintillation detector

    CERN Document Server

    Nittoh, K; Sakurai, T; Yoshida, T; Mochiki, K I

    2003-01-01

    A new imaging system using the multi-color scintillator Gd sub 2 O sub 2 S:Eu has been developed for the X-ray radiography. In this method a color Charge Coupled Device detects the weak blue and green photons associated with the transitions from the terms like sup 5 D sub 1 and sup 5 D sub 2 in the Eu-ions as well as the dominant red photons. As these transitions become appreciable and saturate at quite different intensity levels of the X-ray, we can realize a big extension of the dynamic range of the imaging almost by hundred times in comparison with the conventional monochromatic method. As a result, the new system makes it possible to take a clear image of any complex object, which consists of various parts of the different X-ray penetrability, from plastic to heavy metal, at a single shot.

  10. Applications and characteristics of imaging plates as detector in neutron radiography at SINQ

    CERN Document Server

    Kolbe, H; Gunia, W; Körner, S

    1999-01-01

    Imaging plate technique is a commonly accepted method in many fields as in medicine, biology and physics for detection of the distribution of beta- and gamma-radiation or X-rays on large areas. Recently a new type of imaging plate sensitive to neutrons has been developed. The storage layer is doped with gadolinium, which, after absorption of neutrons, produces radiation detectable by the same sensitive crystals used in conventional imaging plates. At the spallation neutron source, SINQ, at the Paul Scherrer Institut (CH) some of the characteristics of the neutron radiography station in combination with the imaging plate technique were investigated. The intensity distribution of the source was measured to check the accuracy for quantification of the image data. Also, the reproducibility of results obtained by this detection system was stated. For a test object, the high selectivity for different neutron absorption is demonstrated at details with low contrast. The obtainable spatial resolution was determined re...

  11. [Xeroradiography and digital luminescence radiography in the study of the technics of manufacturing ancient ceramics. The advantages and limits].

    Science.gov (United States)

    Meduri, A; Pirronti, T; Calicchio, D; Rispoli, F; Vidale, M; Marano, P

    1993-01-01

    This paper reports on the cooperative work of the Department of Radiology of the Catholic University, Rome, and of the Italian Institute for Middle and Far East. The study was aimed at using xeroradiography and digital luminescence radiography for the archeometric evaluation of ancient ceramics and at assessing the imaging potentials of the two techniques. Some manufacturing techniques are reported which were used in the ancient world and societies for pottery making--i.e., coil building (the superimposition of clay rings), paddle and anvil beating and throwing of the wheel. Such techniques leave, on the vessel's wall, clear traces which can be detected by X-ray imaging. After discussing the main semiologic features, we present 4 case studies from the project archive. Each vase underwent xeroradiography and digital luminescence radiography. The former technique was useful in detailing minor phase transitions--e.g., pores and inclusions--while the latter, thanks to both its wide dynamic range and its image processing potentials, was optimal in defining very gradual thickness transitions due to the different techniques used to join the clay parts. By combining the two techniques, the manufacturing technology of the artifacts could be defined. The interactive processing of radiographic images at the system console was seen to be of major importance: it allowed the best results to be obtained thanks to the integration of the radiologists' and archeologists' know-how during the actual analytical stages.

  12. Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Sund, Patrik; Baath, Magnus; Maansson, Lars Gunnar [Department of Radiation Physics, Goeteborg University, 41345 Goeteborg (Sweden); Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, 41345 Goeteborg (Sweden); Kheddache, Susanne [Department of Radiology, Goeteborg University, 41345 Goeteborg (Sweden); Department of Radiology, Sahlgrenska University Hospital, 41345 Goeteborg (Sweden)

    2004-01-01

    A study was conducted to compare physical and clinical system performance in digital chest radiography. Four digital X-ray modalities, two storage-phosphor based systems and two generations of a CCD-based system, were evaluated in terms of both their imaging properties (determination of presampling MTF and DQE) and clinical image quality (grading of the reproduction of anatomical details of 23 healthy volunteers using both absolute and relative visual grading analysis). One of the two storage-phosphor systems performed best in both evaluations and the first generation of the CCD-based system was rated worst; however, the other two systems were ranked differently with the two methods. The newest CCD-based system yielded a higher clinical image quality than the second storage-phosphor system, although the latter presented a DQE substantially higher than the former. The results show that clinical performance cannot be predicted from determinations of DQE alone, and that a system with lower DQE, under the quantum-saturated conditions in chest radiography, can outperform a system with higher DQE if the image processing used on the former is more effective in presenting the information in the image to the radiologist. (orig.)

  13. Design of the digitizing beam position limit detector.

    Energy Technology Data Exchange (ETDEWEB)

    Merl, R.

    1998-05-27

    The Digitizing Beam Position Limit Detector (DBPLD) is designed to identify and react to beam missteering conditions in the Advanced Photon Source (APS) storage ring. The high power of the insertion devices requires these missteering conditions to result in a beam abort in less than 2 milliseconds. Commercially available beam position monitors provide a voltage proportional to beam position immediately upstream and downstream of insertion devices. The DBPLD is a custom VME board that digitizes these voltages and interrupts the heartbeat of the APS machine protection system when the beam position exceeds its trip limits.

  14. Digital Slot Radiography Based On A Linear X-Ray Image Intensifier And Two-Dimensional Image Sensors.

    Science.gov (United States)

    Beerlage, M. J. M.; Levels, H. P. L.; Mulder, H.

    1986-06-01

    Apart from providing the inherent benefits of digital imaging, a digital chest system should preferably be superior to large-size film with respect to diagnostic quality. Systems, demonstrated until now, tend to fail in that respect. Here we describe a system -under development- that combines the advantages of film (e.g. high resolution), area detectors (wide sensor dynamic range) and slit detectors (efficient reduction of scattered radiation, high contrast resolution and instantaneous image availibility). Thereby the system is low-dose, compact and operating at standard X-ray tube loading.

  15. Digital radiography: optimization of image quality and dose using multi-frequency software

    Energy Technology Data Exchange (ETDEWEB)

    Precht, H. [University College Lillebelt, Conrad Research Center, Odense (Denmark); Gerke, O. [Odense University Hospital, Department of Nuclear Medicine, Odense (Denmark); University of Southern Denmark, Research Unit of Health Economics, Odense (Denmark); Rosendahl, K. [Haukeland University Hospital, Section of Pediatric Radiology, Bergen (Norway); University of Bergen, Institute of Surgical Sciences, Bergen (Norway); Tingberg, A. [Skaane University Hospital, Lund University (Sweden); Medical Radiation Physics, Department of Clinical Sciences, Malmoe (Sweden); Waaler, D. [Gjoevik University College, Gjoevik (Norway)

    2012-09-15

    New developments in processing of digital radiographs (DR), including multi-frequency processing (MFP), allow optimization of image quality and radiation dose. This is particularly promising in children as they are believed to be more sensitive to ionizing radiation than adults. To examine whether the use of MFP software reduces the radiation dose without compromising quality at DR of the femur in 5-year-old-equivalent anthropomorphic and technical phantoms. A total of 110 images of an anthropomorphic phantom were imaged on a DR system (Canon DR with CXDI-50 C detector and MLT[S] software) and analyzed by three pediatric radiologists using Visual Grading Analysis. In addition, 3,500 images taken of a technical contrast-detail phantom (CDRAD 2.0) provide an objective image-quality assessment. Optimal image-quality was maintained at a dose reduction of 61% with MLT(S) optimized images. Even for images of diagnostic quality, MLT(S) provided a dose reduction of 88% as compared to the reference image. Software impact on image quality was found significant for dose (mAs), dynamic range dark region and frequency band. By optimizing image processing parameters, a significant dose reduction is possible without significant loss of image quality. (orig.)

  16. Accuracy of Digital Radiography and Cone Beam Computed Tomography on Periapical Radiolucency Detection in Endodontically Treated Teeth

    Directory of Open Access Journals (Sweden)

    Tadas Venskutonis

    2014-07-01

    Full Text Available Objectives: The aim of the present study was to compare the accuracy of intraoral digital periapical radiography and cone beam computed tomography in the detection of periapical radiolucencies in endodontically treated teeth. Material and Methods: Radiographic images (cone beam computed tomography [CBCT] scans and digital periapical radiography [PR] images from 60 patients, achieved from September 2008 to July 2013, were retrieved from databases of the Department of Oral Diseases, Lithuanian University of Health Sciences. Twenty patients met inclusion criteria and were selected for further evaluation. Results: In 20 patients (42.4 [SD 12.1] years, 65% men and 35% women a total of 35 endodontically treated teeth (1.75 [SD 0.91]; 27 in maxilla and 8 in mandible were evaluated. Overall, it was observed a statistical significant difference between the number of periapical lesions observed in the CBCT (n = 42 and radiographic (n = 24 examinations (P < 0.05. In molar teeth, CBCT identify a significantly higher amount of periapical lesions than with the radiographic method (P < 0.05. There were significant differences between CBCT and PR in the mean number of lesions identified per tooth (1.2 vs 0.66, P = 0.03, number of teeth with lesions (0.71 vs 0.46, P = 0.03 and number of lesions identified per canal (0.57 vs 0.33, P = 0.005. Considering CBCT as “gold standard” in lesion detection with the sensitivity, specificity and accuracy considering as score 1, then the same parameters of PR were 0.57, 1 and 0.76 respectively. Conclusions: Within the limitations of the present study, it can be concluded that cone beam computed tomography scans were more accurate compared to digital periapical radiographs for detecting periapical radiolucencies in endodontically treated teeth. The difference was more pronounced in molar teeth.

  17. Diagnostic Accuracy of Digital and Conventional Radiography in the Detection of Non-Cavitated Approximal Dental Caries

    Directory of Open Access Journals (Sweden)

    Farida Abesi

    2012-03-01

    Full Text Available Background: Radiography plays an important role in the detection of interproximal caries.Objectives: The aim of the present study was to determine diagnostic accuracy of chargecoupled devices (CCD, Photo Stimulable Phosphor (PSP and film radiography in detecting non-cavitated caries.Patients and Methods: Seventy-two non-cavitated approximal surfaces of extracted human posterior teeth were radiographed under standardized conditions using three intraoral modalities: CCD Dixi3 (Planmeca, Finland, PSP Digora PCT (Soredex, Finland, and E-speed film (Kodak, USA. Radiographs were interpreted by four observers and caries lesions were classified as sound (R0, restricted to enamel (R1, reaching the dentinoenamel junction (DEJ and the outer half of the dentin (R2 and the inner half of the dentin (R3. The teeth were subsequently sectioned for histological analysis which served as the gold standard for radiographic examination.Results: Microscopic examinations showed that the distribution of caries were 63.9% sound, 18.1% enamel, 9.7% DEJ and outer half of the dentin and 8.3% into the inner half of the dentin.The sensitivity and specificity of film, CCD and PSP for the detection of enamel caries were 38% and 98%; 15% and 96 %; and 23% and 98%, respectively. The sensitivity and specificity of film, CCD and PSP for the detection of both dentin and enamel caries were 55% and 100%; 45% and 100% ; and 55% and 100%, respectively.Conclusions: The results demonstrated that the diagnostic accuracy of digital images is similar to that of conventional film radiography in the detection of non-cavitated approximal caries.

  18. Comparison of Indirect CsI/a:Si and Direct a:Se Digital Radiography. An assessment of contrast and detail visualization

    Energy Technology Data Exchange (ETDEWEB)

    Fischbach, F.; Freund, T.; Pech, M.; Werk, M.; Bassir, C.; Stoever, B.; Felix, R.; Ricke, J. [Humboldt-Univ. Medical School, Campus Virchow-Klinikum, Berlin (Germany). Dept. of Radiology

    2003-11-01

    Purpose: To assess and quantify the image quality at two dose levels for an amorphous Silicon (a:Si) Cesium Iodide (CsI) flat panel system compared with a direct amorphous Selenium (a:Se) digital radiography system. Material and Methods: A contrast detectability test was performed employing the CDRAD-phantom at mAs-values leading to approximately equal phantom entrance doses of 41.4, 57.9, 75.1 and 120.8 {mu}Gy for the a:Se and 39.9, 58.4, 75.6 and 117.9 {mu}Gy for the CsI system. Images were presented to 4 independent observers. For quantitative comparison, the image quality figure (IQF) was calculated. Statistical analysis was performed using Pearson's correlation and the Wilcoxon test. A ROC-analysis was performed employing the TRG-phantom in a high- and a low-dose setting leading to entrance doses of 126.2 and 35 {mu}Gy for the direct, and 125.9 and 34.4 {mu}Gy for the indirect system. Statistical significance was evaluated using the Wilcoxon test. Results: The flat panel a:Si digital system provided superior results compared with the a:Se drum digital system with respect to low-dose settings for CDRAD-phantom and ROC-analysis, ensuring a better image quality with respect to contrast and detail detectability. Higher-dose settings provided similar results for both systems. Conclusion: Image quality of a:Si flat panel digital radiography proved to be superior to a:Se drum digital radiography using low-dose settings. If the primary target is dose reduction indirect flat panel technology should be used. Digital radiography amorphous selenium amorphous silicon chest radiography.

  19. Development of a mini-mobile digital radiography system by using wireless smart devices.

    Science.gov (United States)

    Jeong, Chang-Won; Joo, Su-Chong; Ryu, Jong-Hyun; Lee, Jinseok; Kim, Kyong-Woo; Yoon, Kwon-Ha

    2014-08-01

    The current technologies that trend in digital radiology (DR) are toward systems using portable smart mobile as patient-centered care. We aimed to develop a mini-mobile DR system by using smart devices for wireless connection into medical information systems. We developed a mini-mobile DR system consisting of an X-ray source and a Complementary Metal-Oxide Semiconductor (CMOS) sensor based on a flat panel detector for small-field diagnostics in patients. It is used instead of the systems that are difficult to perform with a fixed traditional device. We also designed a method for embedded systems in the development of portable DR systems. The external interface used the fast and stable IEEE 802.11n wireless protocol, and we adapted the device for connections with Picture Archiving and Communication System (PACS) and smart devices. The smart device could display images on an external monitor other than the monitor in the DR system. The communication modules, main control board, and external interface supporting smart devices were implemented. Further, a smart viewer based on the external interface was developed to display image files on various smart devices. In addition, the advantage of operators is to reduce radiation dose when using remote smart devices. It is integrated with smart devices that can provide X-ray imaging services anywhere. With this technology, it can permit image observation on a smart device from a remote location by connecting to the external interface. We evaluated the response time of the mini-mobile DR system to compare to mobile PACS. The experimental results show that our system outperforms conventional mobile PACS in this regard.

  20. TH-C-BRD-05: Reducing Proton Beam Range Uncertainty with Patient-Specific CT HU to RSP Calibrations Based On Single-Detector Proton Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Doolan, P [University College London, London (United Kingdom); Massachusetts General Hospital, Boston, MA (United States); Sharp, G; Testa, M; Lu, H-M [Massachusetts General Hospital, Boston, MA (United States); Bentefour, E [Ion Beam Applications (IBA), Louvain la Neuve (Belgium); Royle, G [University College London, London (United Kingdom)

    2014-06-15

    Purpose: Beam range uncertainty in proton treatment comes primarily from converting the patient's X-ray CT (xCT) dataset to relative stopping power (RSP). Current practices use a single curve for this conversion, produced by a stoichiometric calibration based on tissue composition data for average, healthy, adult humans, but not for the individual in question. Proton radiographs produce water-equivalent path length (WEPL) maps, dependent on the RSP of tissues within the specific patient. This work investigates the use of such WEPL maps to optimize patient-specific calibration curves for reducing beam range uncertainty. Methods: The optimization procedure works on the principle of minimizing the difference between the known WEPL map, obtained from a proton radiograph, and a digitally-reconstructed WEPL map (DRWM) through an RSP dataset, by altering the calibration curve that is used to convert the xCT into an RSP dataset. DRWMs were produced with Plastimatch, an in-house developed software, and an optimization procedure was implemented in Matlab. Tests were made on a range of systems including simulated datasets with computed WEPL maps and phantoms (anthropomorphic and real biological tissue) with WEPL maps measured by single detector proton radiography. Results: For the simulated datasets, the optimizer showed excellent results. It was able to either completely eradicate or significantly reduce the root-mean-square-error (RMSE) in the WEPL for the homogeneous phantoms (to zero for individual materials or from 1.5% to 0.2% for the simultaneous optimization of multiple materials). For the heterogeneous phantom the RMSE was reduced from 1.9% to 0.3%. Conclusion: An optimization procedure has been designed to produce patient-specific calibration curves. Test results on a range of systems with different complexities and sizes have been promising for accurate beam range control in patients. This project was funded equally by the Engineering and Physical Sciences

  1. Full Field Digital Mammography (FFDM) versus CMOS Technology, Specimen Radiography System (SRS) and Tomosynthesis (DBT) - Which System Can Optimise Surgical Therapy?

    Science.gov (United States)

    Schulz-Wendtland, R; Dilbat, G; Bani, M; Fasching, P A; Heusinger, K; Lux, M P; Loehberg, C R; Brehm, B; Hammon, M; Saake, M; Dankerl, P; Jud, S M; Rauh, C; Bayer, C M; Beckmann, M W; Uder, M; Meier-Meitinger, M

    2013-05-01

    Aim: This prospective clinical study aimed to evaluate whether it would be possible to reduce the rate of re-excisions using CMOS technology, a specimen radiography system (SRS) or digital breast tomosynthesis (DBT) compared to a conventional full field digital mammography (FFDM) system. Material and Method: Between 12/2012 and 2/2013 50 patients were diagnosed with invasive breast cancer (BI-RADS™ 5). After histological verification, all patients underwent breast-conserving therapy with intraoperative imaging using 4 different systems and differing magnifications: 1. Inspiration™ (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm pixel pitch, 8 lp/mm; 2. BioVision™ (Bioptics, Tucson, AZ, USA), CMOS technology, photodiode array, flat panel, tungsten source, focus 0.05, resolution 50 µm pixel pitch, 12 lp/mm; 3. the Trident™ specimen radiography system (SRS) (Hologic, Bedford, MA, USA), amorphous selenium, tungsten source, focus 0.05, resolution 70 µm pixel pitch, 7.1 lp/mm; 4. tomosynthesis (Siemens, Erlangen, Germany), amorphous selenium, tungsten source, focus 0.1 mm, resolution 85 µm pixel pitch, 8 lp/mm, angular range 50 degrees, 25 projections, scan time > 20 s, geometry: uniform scanning, reconstruction: filtered back projection. The 600 radiographs were prospectively shown to 3 radiologists. Results: Of the 50 patients with histologically proven breast cancer (BI-RADS™ 6), 39 patients required no further surgical therapy (re-excision) after breast-conserving surgery. A retrospective analysis (n = 11) showed a significant (p < 0.05) increase of sensitivity with the BioVision™, the Trident™ and tomosynthesis compared to the Inspiration™ at a magnification of 1.0 : 2.0 or 1.0 : 1.0 (tomosynthesis) (2.6, 3.3 or 3.6 %), i.e. re-excision would not have been necessary in 2, 3 or 4 patients, respectively, compared to findings obtained with a standard

  2. Diagnostic Accuracy of CBCT with Different Voxel Sizes and Intraoral Digital Radiography for Detection of Periapical Bone Lesions: An Ex-Vivo Study

    OpenAIRE

    Shirin Sakhdari; Ahmad Reza Talaeipour; Maziar Talaeipour; Maryam Pazhutan; Sanaz Heidarkhan Tehrani; Mohammad Javad Kharazifard

    2016-01-01

    Objectives: This study sought to assess the diagnostic accuracy of cone beam computed tomography (CBCT) with different voxel sizes and intraoral digital radiography with photostimulable phosphor (PSP) plate for detection of periapical (PA) bone lesions.Materials and Methods: In this ex vivo diagnostic study, one-millimeter defects were created in the alveolar sockets of 15 bone blocks, each with two posterior teeth. A no-defect control group was also included. Digital PA radiographs with PSP ...

  3. Comparison study on CNR and SNR of thoracic spine lateral radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ki Won [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Min, Jung Whan; Lyu, Kwang Yeul [Dept. of Radiology, Shingu University, Sungnam (Korea, Republic of); Kim, Jung Min [Dept. of Radiological Science, College of Health Science, Korea University, Seoul (Korea, Republic of); Jeong, Hei Woun [Dept. of Radiological Science, Beakseok Culture University, Cheonan (Korea, Republic of); Lee, Joo Ah [Dept. of Oncology, Catholic University of Korea Incheon St.Mary,s Hospital, Incheon (Korea, Republic of); Jung, Jae Hong [Dept. of Oncology, Soonchunhyang University Bucheon Hospital, Bucheon (Korea, Republic of); Sung, Dong Chan [Dept. of Radiology, Dong Guk University Medical Center, Seoul (Korea, Republic of); Park, Soon Cheol [Dept. of Radiology, Kang Dong Kyung Hee University Medical Center, Seoul (Korea, Republic of)

    2013-12-15

    This study was proven for the T-spine breathing technique in lateral projection, using computer radiography (CR), charge coupled device (CCD), indirect digital radiography (IDR) and direct digital radiography (DDR). All images were evaluated and compared with CNR and SNR measured with the mean pixels and the standard deviation as setting ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk using Image J. In experiment results of 4 type detectors, T-spine breathing technique was indicated as excellent in ROI of spinous process, pedicle, vertebral body, intervertebral foramen and intervertebral disk. As T-spine breathing technique indicated excellent images compared to the existing T-spine lateral radiography, this method would be useful for elderly patients who have difficulty in deep exhalation. This study was indicated the application possibility of T-spine breathing technique by presenting contrast to noise ratio (CNR) and signal to noise ratio (SNR) with quantitative value in 4 type detectors.

  4. Characterisation of Late Bronze Age large size shield nails by EDXRF, micro-EDXRF and X-ray digital radiography.

    Science.gov (United States)

    Figueiredo, E; Araújo, M F; Silva, R J C; Senna-Martinez, J C; Vaz, J L Inês

    2011-09-01

    In the present study six exceptional large size metallic nails, a dagger and a sickle from the Late Bronze Age archaeological site of Figueiredo das Donas (Central Portugal) have been analysed by EDXRF, micro-EDXRF and X-ray digital radiography for the study of material composition and technology of fabrication. The combination of these analytical and examination techniques showed that all artefacts are made of bronze with As, Sb and Pb impurities, and that the nails were most likely manufactured using the casting-on technique. These results reinforce the use of binary bronze by Late Bronze Age in the region, and the incorporation of new fabrication technologies that resulted from ancient spheres of interaction.

  5. New standards for digital radiography and qualification of detectors; Neue Standards zur Digitalen Radiographie und Qualifizierung von Detektoren

    Energy Technology Data Exchange (ETDEWEB)

    Ewert, Uwe; Zscherpel, Uwe [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany)

    2017-08-01

    The contribution describes the most important standards for radiographic examinations that are revised in different committees. Information is given on new requirements esp. on revised parameters that have to be considered in practical testing procedures and classification. Actually for the revision of ISO 17636-1/2 in 2018 user questions are collected concerning weld seam testing. The DIN 25435 standards for weld seam testing in nuclear technology have been translated into English. Revisions of ASTM standards have to be considered in the actual EN and ISO standards. Since several years the International Institute of Welding (IIW) is also revising the international standards.

  6. The efficacy of the reverse contrast mode in digital radiography for the detection of proximal dentinal caries

    Energy Technology Data Exchange (ETDEWEB)

    Miri, Shimasadat [Dept. of Endodontics, School of Dentistry, Kermanshah University of Medical Sciences, Kermanshah (Iran, Islamic Republic of); Mehrailzadeh, Sandra; Sadri, Donya [School of Dentistry, Islamic Azad University, Tehran (Iran, Islamic Republic of); Motamedi, Mahmood Reza Kalantar [Dept. of Research, School of Dentistry, Isfahan Branch, Islamic Azad University, Isfahan (Iran, Islamic Republic of); Soltani, Parisa [Dental Students Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan (Iran, Islamic Republic of)

    2015-09-15

    This study evaluated the diagnostic accuracy of the reverse contrast mode in intraoral digital radiography for the detection of proximal dentinal caries, in comparison with the original digital radiographs. Eighty extracted premolars with no clinically apparent caries were selected, and digital radiographs of them were taken separately in standard conditions. Four observers examined the original radiographs and the same radiographs in the reverse contrast mode with the goal of identifying proximal dentinal caries. Microscopic sections 5 µm in thickness were prepared from the teeth in the mesiodistal direction. Four slides prepared from each sample used as the diagnostic gold standard. The data were analyzed using SPSS (α=0.05). Our results showed that the original radiographs in order to identify proximal dentinal caries had the following values for sensitivity, specificity, positive predictive value, negative predictive value, and accuracy, respectively: 72.5%, 90%, 87.2%, 76.5%, and 80.9%. For the reverse contrast mode, however, the corresponding values were 63.1%, 89.4%, 87.1%, 73.5%, and 78.8%, respectively. The sensitivity of original digital radiograph for detecting proximal dentinal caries was significantly higher than that of reverse contrast mode (p<0.05). However, no statistically significant differences were found regarding specificity, positive predictive value, negative predictive value, or accuracy (p>0.05). The sensitivity of the original digital radiograph for detecting proximal dentinal caries was significantly higher than that of the reversed contrast images. However, no statistically significant differences were found between these techniques regarding specificity, positive predictive value, negative predictive value, or accuracy.

  7. [Digital thoracic radiology: devices, image processing, limits].

    Science.gov (United States)

    Frija, J; de Géry, S; Lallouet, F; Guermazi, A; Zagdanski, A M; De Kerviler, E

    2001-09-01

    In a first part, the different techniques of digital thoracic radiography are described. Since computed radiography with phosphore plates are the most commercialized it is more emphasized. But the other detectors are also described, as the drum coated with selenium and the direct digital radiography with selenium detectors. The other detectors are also studied in particular indirect flat panels detectors and the system with four high resolution CCD cameras. In a second step the most important image processing are discussed: the gradation curves, the unsharp mask processing, the system MUSICA, the dynamic range compression or reduction, the soustraction with dual energy. In the last part the advantages and the drawbacks of computed thoracic radiography are emphasized. The most important are the almost constant good quality of the pictures and the possibilities of image processing.

  8. Basic imaging properties of an indirect flat-panel detector system employing irradiation side sampling (ISS) technology for chest radiography: comparison with a computed radiographic system.

    Science.gov (United States)

    Tanaka, Nobukazu; Yano, Yuki; Yabuuchi, Hidetake; Akasaka, Tsutomu; Sasaki, Masayuki; Ohki, Masafumi; Morishita, Junji

    2013-01-01

    The image quality and potential usefulness for patient skin-dose reduction of a newly developed flat-panel detector (FPD) system employing irradiation side sampling (ISS) were investigated and compared to a conventional computed radiography (CR) system. We used the X-ray beam quality of RQA 9 as noted in the standard evaluation method by the International Electrotechnical Commission 62220-1 to evaluate the image quality of the detector for chest radiography. The presampled modulation transfer function (MTF) of the ISS-FPD system was slightly higher than that of the CR system in the horizontal direction at more than 2.2 cycles/mm. However, the presampled MTF of the ISS-FPD system was slightly lower than that of the CR system in the vertical direction. The Wiener spectrum of the ISS-FPD system showed a 50-65 % lesser noise level than that of the CR system under the same exposure condition. The detective quantum efficiency of the ISS-FPD system was at least twice as great as that of the CR system. We conclude that the ISS-FPD system has the potential to reduce the patient skin dose compared to a conventional CR system for chest radiography.

  9. Paediatric dose measurement in a full-body digital radiography unit

    Energy Technology Data Exchange (ETDEWEB)

    Maree, Gert J.; Hering, Egbert R. [Groote Schuur Hospital and University of Cape Town, Division of Medical Physics, Cape Town (South Africa); Irving, Benjamin J. [University of Cape Town, MRC/UCT Medical Imaging Research Unit, Department of Human Biology, Cape Town, Western Cape (South Africa)

    2007-10-15

    Ionizing radiation has a detrimental effect on the human body, particularly in children. Thus it is important to minimize the dose. Linear slit-scanning X-ray units offer the possibility of dose reductions. In order to further develop linear slit-scanning radiography, the dose needs to be accurately calculated for various examinations. To measure the entrance dose (free-in-air) and calculate the effective doses for various radiological examinations in children on Lodox Statscan and Shimadzu radiography units. Entrance doses (free-in-air) were measured using a dose meter and ionization chamber on the Statscan and Shimadzu units at two South African hospitals. The entrance doses were measured for a number of common examinations and were used to compute the effective dose using a Monte Carlo program. The standard deviation of the entrance doses was in the range 0-0.6%. The effective dose from the Statscan unit was well below that from the Shimadzu unit as well as that found in other radiological studies from around the world in children. The one exception was chest examination where the dose was similar to that in other studies worldwide due to the use of Chest AP projection compared to Chest PA used in the comparitive studies. Linear slit-scanning systems help reduce the dose in radiological examinations in children. (orig.)

  10. Comparison of craniofacial linear measurements of 20-40 year-old males and females using digital lateral cephalometric radiography in Indonesia

    Science.gov (United States)

    Aurizanti, D.; Suryonegoro, H.; Priaminiarti, M.

    2017-08-01

    Craniofacial characteristics are one of the sex determination parameters of age after puberty. The aim of this study is to obtain linear measurements using lateral cephalometric radiography of adults aged 20-40 years based on sex in Indonesia. Ten linear craniofacial parameters on 100 digital lateral cephalometric radiographs were measured. Inter-intra observer reliability was tested using Technical Error Measurement. The independent t-test and the Mann-Whitney U test were used to evaluate the significance of the findings. There are significant differences between males and females on 10 of the linear measurements using lateral cephalometric radiography. Lateral cephalometric radiography showed that the linear measurements of 10 cephalometic parameters were higher in males than females, so it can be used to determine sex.

  11. Absorbed organ and effective doses from digital intra-oral and panoramic radiography applying the ICRP 103 recommendations for effective dose estimations.

    Science.gov (United States)

    Granlund, Christina; Thilander-Klang, Anne; Ylhan, Betȕl; Lofthag-Hansen, Sara; Ekestubbe, Annika

    2016-10-01

    During dental radiography, the salivary and thyroid glands are at radiation risk. In 2007, the International Commission on Radiological Protection (ICRP) updated the methodology for determining the effective dose, and the salivary glands were assigned tissue-specific weighting factors for the first time. The aims of this study were to determine the absorbed dose to the organs and to calculate, applying the ICRP publication 103 tissue-weighting factors, the effective doses delivered during digital intraoral and panoramic radiography. Thermoluminescent dosemeter measurements were performed on an anthropomorphic head and neck phantom. The organ-absorbed doses were measured at 30 locations, representing different radiosensitive organs in the head and neck, and the effective dose was calculated according to the ICRP recommendations. The salivary glands and the oral mucosa received the highest absorbed doses from both intraoral and panoramic radiography. The effective dose from a full-mouth intraoral examination was 15 μSv and for panoramic radiography, the effective dose was in the range of 19-75 μSv, depending on the panoramic equipment used. The effective dose from a full-mouth intraoral examination is lower and that from panoramic radiography is higher than previously reported. Clinicians should be aware of the higher effective dose delivered during panoramic radiography and the risk-benefit profile of this technique must be assessed for the individual patient. The effective dose of radiation from panoramic radiography is higher than previously reported and there is large variability in the delivered radiation dosage among the different types of equipment used.

  12. Single-image hard-copy display of the spine utilizing digital radiography

    Science.gov (United States)

    Artz, Dorothy S.; Janchar, Timothy; Milzman, David; Freedman, Matthew T.; Mun, Seong K.

    1997-04-01

    Regions of the entire spine contain a wide latitude of tissue densities within the imaged field of view presenting a problem for adequate radiological evaluation. With screen/film technology, the optimal technique for one area of the radiograph is sub-optimal for another area. Computed radiography (CR) with its inherent wide dynamic range, has been shown to be better than screen/film for lateral cervical spine imaging, but limitations are still present with standard image processing. By utilizing a dynamic range control (DRC) algorithm based on unsharp masking and signal transformation prior to gradation and frequency processing within the CR system, more vertebral bodies can be seen on a single hard copy display of the lateral cervical, thoracic, and thoracolumbar examinations. Examinations of the trauma cross-table lateral cervical spine, lateral thoracic spine, and lateral thoracolumbar spine were collected on live patient using photostimulable storage phosphor plates, the Fuji FCR 9000 reader, and the Fuji AC-3 computed radiography reader. Two images were produced from a single exposure; one with standard image processing and the second image with the standard process and the additional DRC algorithm. Both sets were printed from a Fuji LP 414 laser printer. Two different DRC algorithms were applied depending on which portion of the spine was not well visualized. One algorithm increased optical density and the second algorithm decreased optical density. The resultant image pairs were then reviewed by a panel of radiologists. Images produced with the additional DRC algorithm demonstrated improved visualization of previously 'under exposed' and 'over exposed' regions within the same image. Where lung field had previously obscured bony detail of the lateral thoracolumbar spine due to 'over exposure,' the image with the DRC applied to decrease the optical density allowed for easy visualization of the entire area of interest. For areas of the lateral cervical spine

  13. Digital filters in radio detectors of the Pierre Auger Observatory

    Science.gov (United States)

    Szadkowski, Zbigniew; Głas, Dariusz

    2016-09-01

    Ultra-high energy cosmic rays (UHECR) are the most energetic observable particles in Universe. The main challenge in detecting such energetic particles is very small flux. Most experiments focus on detecting Extensive Air Showers (EAS), initiated by primary UHECR particle in interaction with particles of the atmosphere. One of the observation method is detecting the radio emission from the EAS. This emission was theoretically suggested in 1960's, but technological development allow successful detection only in the last several years. This detection technique is used by Auger Engineering Radio Array (AERA). Most of the emission can be observed in frequency band 30 - 80 MHz, however this range is contaminated by radio frequency interferences (RFI). These contaminations must be reduced to decrease false trigger rate. Currently, there are two kind of digital filters used in AERA. One of them is median filter, based on Fast Fourier Transform. Second one is the notch filter, which is a composition of four infinite impulse response filters. Those filters have properly work in AERA radio detectors for many years. Dynamic progress in electronics allows to use more sophisticated algorithms of RFI reduction. Planned modernization of the AERA radio detectors' electronic allows to use finte impulse response (FIR) filters, which can fast adapt to environment conditions. These filters are: Least Mean Squares (LMS) filter and filter based on linear prediction (LP). Tests of new kind of filters are promising and show that FIR filters can be used in next generation radio detectors in AERA experiment.

  14. Value of digital radiography in expiration in detection of pneumothorax; Wertigkeit der digitalen Roentgenaufnahme in Exspiration zum Nachweis eines Pneumothorax

    Energy Technology Data Exchange (ETDEWEB)

    Thomsen, L.; Natho, O.; Feigen, U.; Kivelitz, D. [Asklepios Klinik St. Georg, Hamburg (Germany). Dept. of Radiology; Schulz, U. [medistat GmbH, Kiel (Germany). Medical Statistics

    2014-03-15

    Purpose: The purpose of this study was to find out whether pneumothorax detection and exclusion is superior in expiratory digital chest radiography. Materials and Methods: 131 patients with pneumothorax with paired inspiratory and expiratory chest radiographs were analyzed regarding localization and size of pneumothorax. Sensitivity, specificity, negative (npv) and positive predictive value (ppv) as well as the positive (LR+) and negative likelihood ratio (LR-) were determined in a blinded randomized interobserver study with 116 patients. The evaluation was performed by three board-certified radiologists. Results: In 131 patients, there were 139 pneumothoraces, 135 (97.1 %) were located apical, 88 (63.3 %) lateral and 33 (23.7 %) basal. Sensitivity was 99 % for inspiratory and 97 % for expiratory radiographs. The interobserver study yielded a mean sensitivity of 86.1 %/86.1 %, specificity of 97.3 %/93.4 %, npv of 88.7 %/88.5 % and ppv of 96.7 %/92.1 % for inspiration/expiration. For inspiratory radiographs the LR+/LR- were 40.2/0.14 and for expiration 13.9 and 0.15. McNemar-Test showed no significant difference for the detection of pneumothoraces in in-/exspiration. Conclusion: Inspiratory and expiratory digital radiographs are equally suitable for pneumothorax detection. Inspiratory radiographs are recommended as the initial examination of choice for pneumothorax detection, an additional expiratory radiograph is only recommended in doubtful cases. (orig.)

  15. Evaluation of the effective detective quantum efficiency for various tube voltages with digital radiography for chest imaging

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Hyo-Min; Kim, Hee-Joung; Park, Hye-Suk; Kim, Dae-Hong; Lee, Chang-Lae; Choi, Yu-Na; Lee, Seung-Wan [Yonsei University, Wonju (Korea, Republic of)

    2011-03-15

    The concept of effective detective quantum efficiency (eDQE) has recently been developed and introduced. The purpose of this study was to use the eDQE to evaluate the effect of tube voltage and grid for chest imaging with a direct flat-panel-based digital radiographic system. The exposure factors that we considered were the tube potential and an anti-scatter moving grid. The incident air kerma was adjusted for each tube potential to yield an effective dose of 34 {mu}Sv. The scatter fraction (SF), transmission fraction (TF), effective modulation transfer function (eMTF), and effective normalized noise power spectrum (eNNPS) were measured using a phantom that simulate the attenuation and scatter properties of the human chest. Our results showed that the resolution properties measured by using eMTFs were independent of the tube potential regardless of whether or not a grid was used. The noise properties through the phantom were greater with the use of an anti-scatter grid than without while the eDQE was largest at a lower tube potential, which we tested without a grid. In conclusion, we measured a high efficiency at a low tube potential without an anti-scatter grid for digital radiography (DR) in chest imaging. The eDQE reflected the real exam environment better than the general DQE because it better reflected the effect of the total X-ray system.

  16. Diagnostic Accuracy of CBCT with Different Voxel Sizes and Intraoral Digital Radiography for Detection of Periapical Bone Lesions: An Ex-Vivo Study

    Directory of Open Access Journals (Sweden)

    Shirin Sakhdari

    2016-10-01

    Full Text Available Objectives: This study sought to assess the diagnostic accuracy of cone beam computed tomography (CBCT with different voxel sizes and intraoral digital radiography with photostimulable phosphor (PSP plate for detection of periapical (PA bone lesions.Materials and Methods: In this ex vivo diagnostic study, one-millimeter defects were created in the alveolar sockets of 15 bone blocks, each with two posterior teeth. A no-defect control group was also included. Digital PA radiographs with PSP plates and CBCT scans with 200, 250 and 300μ voxel sizes were obtained. Four observers evaluated the possibility of lesion detection using a 5-point scale. Sensitivity, specificity, positive predictive value (PPV and negative predicative value (NPV were analyzed using one-way ANOVA and Tamhane’s post hoc test. Kappa and weighted kappa statistics were applied to assess intraobserver and interobserver agreements.Results: Cochrane Q test showed no significant difference between PSP and CBCT imaging modalities in terms of kappa and weighted kappa statistics (P=0.675. The complete sensitivity and complete NPV for 200 and 250 μ voxel sizes were higher than those of 300 μ voxel size and digital radiography (P<0.001. No significant difference was noted in other parameters among other imaging modalities (P=0.403.Conclusions: The results showed that high-resolution CBCT scans had higher diagnostic accuracy than PSP digital radiography for detection of artificially created PA bone lesions. Voxel size (field of view must be taken into account to minimize patient radiation dose.Keywords: Diagnosis; Cone-Beam Computed Tomography; Radiography, Dental, Digital; Periapical Periodontitis

  17. Design and image-quality performance of high resolution CMOS-based X-ray imaging detectors for digital mammography

    Science.gov (United States)

    Cha, B. K.; Kim, J. Y.; Kim, Y. J.; Yun, S.; Cho, G.; Kim, H. K.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2012-04-01

    In digital X-ray imaging systems, X-ray imaging detectors based on scintillating screens with electronic devices such as charge-coupled devices (CCDs), thin-film transistors (TFT), complementary metal oxide semiconductor (CMOS) flat panel imagers have been introduced for general radiography, dental, mammography and non-destructive testing (NDT) applications. Recently, a large-area CMOS active-pixel sensor (APS) in combination with scintillation films has been widely used in a variety of digital X-ray imaging applications. We employed a scintillator-based CMOS APS image sensor for high-resolution mammography. In this work, both powder-type Gd2O2S:Tb and a columnar structured CsI:Tl scintillation screens with various thicknesses were fabricated and used as materials to convert X-ray into visible light. These scintillating screens were directly coupled to a CMOS flat panel imager with a 25 × 50 mm2 active area and a 48 μm pixel pitch for high spatial resolution acquisition. We used a W/Al mammographic X-ray source with a 30 kVp energy condition. The imaging characterization of the X-ray detector was measured and analyzed in terms of linearity in incident X-ray dose, modulation transfer function (MTF), noise-power spectrum (NPS) and detective quantum efficiency (DQE).

  18. Comprehensive Optimization Process of Paranasal Sinus Radiography

    Energy Technology Data Exchange (ETDEWEB)

    Saarakkala, S. (Dept. of Clinical Radiology, Kuopio Univ. Hospital, Kuopio (Finland)); Nironen, K.; Hermunen, H.; Aarnio, J.; Heikkinen, J.O. (Dept. of Radiology, Etel-Savo Hospital District, Mikkeli Central Hospital, Mikkeli (Finland))

    2009-04-15

    Background: The optimization of radiological examinations is important in order to reduce unnecessary patient radiation exposure. Purpose: To perform a comprehensive optimization process for paranasal sinus radiography at Mikkeli Central Hospital (Finland). Material and Methods: Patients with suspicion of acute sinusitis were imaged with a Kodak computed radiography (CR) system (n=20) and with a Philips digital radiography (DR) system (n=30) using focus-detector distances (FDDs) of 110 cm, 150 cm, or 200 cm. Patients' radiation exposure was determined in terms of entrance surface dose and dose-area product. Furthermore, an anatomical phantom was used for the estimation of point doses inside the head. Clinical image quality was evaluated by an experienced radiologist, and physical image quality was evaluated from the digital radiography phantom. Results: Patient doses were significantly lower and image quality better with the DR system compared to the CR system. The differences in patient dose and physical image quality were small with varying FDD. Clinical image quality of the DR system was lowest with FDD of 200 cm. Further, imaging with FDD of 150 cm was technically easier for the technologist to perform than with FDD of 110 cm. Conclusion: After optimization, it was recommended that the DR system with FDD of 150 cm should always be used at Mikkeli Central Hospital. We recommend this kind of comprehensive approach in all optimization processes of radiological examinations.

  19. The teaching of computer programming and digital image processing in radiography.

    Science.gov (United States)

    Allan, G L; Zylinski, J

    1998-06-01

    The increased use of digital processing techniques in Medical Radiations imaging modalities, along with the rapid advance in information technology has resulted in a significant change in the delivery of radiographic teaching programs. This paper details a methodology used to concurrently educate radiographers in both computer programming and image processing. The students learn to program in visual basic applications (VBA), and the programming skills are contextualised by requiring the students to write a digital subtraction angiography (DSA) package. Program code generation and image presentation interface is undertaken by the spreadsheet Microsoft Excel. The user-friendly nature of this common interface enables all students to readily begin program creation. The teaching of programming and image processing skills by this method may be readily generalised to other vocational fields where digital image manipulation is a professional requirement.

  20. Standard practice for radiological examination using digital detector arrays

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice establishes the minimum requirements for radiological examination for metallic and nonmetallic material using a digital detector array (DDA) system. 1.2 The requirements in this practice are intended to control the quality of radiologic images and are not intended to establish acceptance criteria for parts or materials. 1.3 This practice covers the radiologic examination with DDAs including DDAs described in Practice E2597 such as a device that contains a photoconductor attached to a Thin Film Transistor (TFT) read out structure, a device that has a phosphor coupled directly to an amorphous silicon read-out structure, and devices where a phosphor is coupled to a CMOS (Complementary metal–oxide–semiconductor) array, a Linear Detector Array (LDA) or a CCD (charge coupled device) crystalline silicon read-out structure. 1.4 The DDA shall be selected for an NDT application based on knowledge of the technology described in Guide , and of the selected DDA properties provided by the manufactu...

  1. Optimized digital filtering techniques for radiation detection with HPGe detectors

    Science.gov (United States)

    Salathe, Marco; Kihm, Thomas

    2016-02-01

    This paper describes state-of-the-art digital filtering techniques that are part of GEANA, an automatic data analysis software used for the GERDA experiment. The discussed filters include a novel, nonlinear correction method for ballistic deficits, which is combined with one of three shaping filters: a pseudo-Gaussian, a modified trapezoidal, or a modified cusp filter. The performance of the filters is demonstrated with a 762 g Broad Energy Germanium (BEGe) detector, produced by Canberra, that measures γ-ray lines from radioactive sources in an energy range between 59.5 and 2614.5 keV. At 1332.5 keV, together with the ballistic deficit correction method, all filters produce a comparable energy resolution of ~1.61 keV FWHM. This value is superior to those measured by the manufacturer and those found in publications with detectors of a similar design and mass. At 59.5 keV, the modified cusp filter without a ballistic deficit correction produced the best result, with an energy resolution of 0.46 keV. It is observed that the loss in resolution by using a constant shaping time over the entire energy range is small when using the ballistic deficit correction method.

  2. Image quality analysis vs dose to the patient in digital panoramic radiography; Analisis de calidad de imagen vs dosis aplicada al paciente en radiografia panoramica digital

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Diaz, M.; Borges-Garcia, T.; Leon-Santana, J.; Vanderley-Brasileiro, I.; Khoury, H.; Miranda-Cataneda, M.

    2012-11-01

    Digital panoramic radiography is a diagnostic image technique which is increasing its use today allo over the world. Nevertheless, there is a relative lack of knowledge about the best compromise relationship between image quality and dose to the patient for these studies. Twenty one panoramic images of an anthropomorphic phantom and 205 from patients were collected using a Kodak digital equipment. Tube current, beam energy and acquisitions time were changed among studies to look for the best acquisition conditions which permit good image quality al low doses for patients. Air Kerma-Length Product was measures as dose index. Image quality was graded using objective metrics as Signal to Noise Ratio (SNR [dB]) and Contrast to Noise ratio (CNR), as well as visual evaluation with two expert observers. Reduction in dose was able, reducing mAs mainly, without affecting image quality in a sensitive way. An optimized protocol for this equipment was also obtained for standard height and weight patients. (Author)

  3. Detection of tuberculosis with digital chest radiography: automatic reading versus interpretation by clinical officers

    NARCIS (Netherlands)

    Maduskar, P.; Muyoyeta, M.; Ayles, H.; Hogeweg, L.E.; Peters-Bax, L.; Ginneken, B. van

    2013-01-01

    SETTING: A busy urban health centre in Lusaka, Zambia. OBJECTIVE: To compare the accuracy of automated reading (CAD4TB) with the interpretation of digital chest radiograph (CXR) by clinical officers for the detection of tuberculosis (TB). DESIGN: A retrospective analysis was performed on 161

  4. Direct digital radiography for the detection of defects in a standard aluminium test object through composite resin restorative materials.

    Science.gov (United States)

    Golubow, N A; Farman, A G; von Fraunhofer, J A; Kelly, M S

    1994-05-01

    While the RVG 32000 (Trophy Radiologie, Vincennes, France) is in wide use for direct digital intraoral radiography in dentistry, there is a dearth of information in the literature concerning the system's sensitivity to small changes in radiographic density consistent with initial and recurrent dental caries. A standardized 7 mm aluminium test block was used as a phantom for perceptibility testing of density changes, both with and without the superimposition of composite resin sheets of various thicknesses. Defects in the block were randomly positioned and varied from 0.1 to 1.5 mm. Thermal prints were used for evaluation. Standard linear images, with no enhancement, were compared with three enhanced modes, standard mode with gradient enhancement (enhanced standard), standard X-function and zoom high resolution (ZHR). Sensitivity improved in the following sequence: standard 0.58 < enhanced standard 0.75 < X-function 0.94 < ZHR 0.95. Accuracy improved in the following sequence: standard 0.45 < enhanced standard 0.58 < X-function 0.73 < ZHR 0.74. Specificity was 1.0 both for X-function and for ZHR. These two modes both proved significantly better (P < 0.05) for the detection of 0.1 mm defects than the other two modes tested. No significant difference was found between X-function and ZHR. As ZHR requires four times the radiation exposure as standard exposures with the X-function, the latter is preferred for the task described in this study.

  5. Analysis of the impact of digital tomosynthesis on the radiological investigation of patients with suspected pulmonary lesions on chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Quaia, Emilio; Baratella, Elisa; Cernic, Stefano; Lorusso, Arianna; Casagrande, Federica; Cioffi, Vincenzo; Cova, Maria Assunta [University of Trieste (Italy), Department of Radiology, Cattinara Hospital, Trieste (Italy)

    2012-09-15

    To assess the impact of digital tomosynthesis (DTS) on the radiological investigation of patients with suspected pulmonary lesions on chest radiography (CXR). Three hundred thirty-nine patients (200 male; age, 71.19 {+-} 11.9 years) with suspected pulmonary lesion(s) on CXR underwent DTS. Two readers prospectively analysed CXR and DTS images, and recorded their diagnostic confidence: 1 or 2 = definite or probable benign lesion or pseudolesion deserving no further diagnostic workup; 3 = indeterminate; 4 or 5 = probable or definite pulmonary lesion deserving further diagnostic workup by computed tomography (CT). Imaging follow-up by CT (n = 76 patients), CXR (n = 256) or histology (n = 7) was the reference standard. DTS resolved doubtful CXR findings in 256/339 (76 %) patients, while 83/339 (24 %) patients proceeded to CT. The mean interpretation time for DTS (mean {+-} SD, 220 {+-} 40 s) was higher (P < 0.05; Wilcoxon test) than for CXR (110 {+-} 30 s), but lower than CT (600 {+-} 150 s). Mean effective dose was 0.06 mSv (range 0.03-0.1 mSv) for CXR, 0.107 mSv (range 0.094-0.12 mSv) for DTS, and 3 mSv (range 2-4 mSv) for CT. DTS avoided the need for CT in about three-quarters of patients with a slight increase in the interpretation time and effective dose compared to CXR. (orig.)

  6. X-Ray Digital Radiography and Computed Tomography Characterization of Targets

    Energy Technology Data Exchange (ETDEWEB)

    Sain, J D; Brown, W D; Chinn, D J; Martz Jr., H E; Morales, K E; Schneberk, D J; Updike, E O

    2008-04-16

    The summary of this report is: (1) The Xradia Micro XCT and LLNL CCAT x-ray systems are used to nondestructively characterize a variety of materials, assemblies, and reference standard components; (2) The digital radiograph (DR) and computed tomography (CT) image data may be used for metrology, quality control, and defect detection; and (3) The ability to detect and characterize imperfections leads to improvements in the manufacturing processes for assemblies.

  7. A quantitative study of bone repair after endodontic therapy on digital subtraction radiography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Duk [Dept. of Oral and Maxillofacial Radiology, College of Dentistry, Chosun University, Kwangju (Korea, Republic of)

    1997-08-15

    This study was performed to prepare the quantitative method of judging the sensitive prognosis of chronic apical periodontitis as early as possible. The subjects were 25 cases with periapical radiolucencies of which were treated with endodontic treatment. Serial radiographs were taken by standardized method longitudinally. The density slice function of digital radiographic system were employed for quantitative and longitudinal assessment of the radiolucent area and the condensing osteitis simultaneously. Obtained results were as follows: 1. The amount of bone repair after endodontic treatment could be detected quantitatively by the density slice function of digital radiographic system. 2. Within the 6-week period after root canal filling, the prognosis could be evaluated by assessment both radiolucent area and condensing osteitis on digital radiographic system. 3. The pattern of bone repair showed peripheral type in most cases from the 6th week after root canal filling. 4. In longitudinal change, bone repair showed two patterns; the succeeding reduction of radiolucent area showing the increase of condensing osteitis in size till 6th week and following by static state or reduction tendency and the reduction following the initial increase of both areas. 5. Cases with pulpitis by trauma showed initial increase of condensing osteitis at 2nd week, marked reduction of radiolucent area and condensing osteitis at 6th week, and approximately normal bone state at 8th week after root canal filling.

  8. Radiopacity of restorative composites by conventional radiography and digital images with different resolutions

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Raquel Venancio; Samento, Hugo Ramalho [Graduate Program in Dentistry, Federal University of Pelotas, Pelotas (Brazil); Duarte, Rosangela Marques; Raso, Sonia Saeger Meireles Monte; De Andrade Ana Karina Maciel; Anjos-Pontual Maria Luiza Dos [Dept. of Operative Dentistry, Federal University of Paraiba, Pelotas (Brazil)

    2013-09-15

    This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using 4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey's test (p<0.05), considering the material factor and then the radiographic method factor, individually. The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

  9. JB/T4730.11射线数字成像标准制定的关键技术探讨%The Key Technology Discussing of JB/T 4730. 11 Digital Radiography Standard Setting

    Institute of Scientific and Technical Information of China (English)

    梁丽红

    2011-01-01

    In order to popularize application of digital radiography technology in the special equipment field, and promote the special inspecting level in nondestructive testing industry, improve the efficiency of special equipment inspecting, and reduce the inspecting complexity for staff, and decrease environmental pollution. The advanced technology of digital radiography should be masted and the relevant testing standards should be established. Some key technologies of standards setting include: ① The components of digital radiography system in standards. ② The differences of image quality evaluation between digital radiography and film radiography. ③ The consistency and equivalence between digital radiography and film radiography. ④other technologies should be concerned in digital radiography.%为在特种设备行业推广和应用射线数字成像检测技术。提高特种设备检测效率、降低检测人员的工作强度、减少环境污染,提升特检行业的无损检测水平,必须掌握先进的数字成像检测技术,制定相关的检测标准。以下是标准制定的几个关键问题:①标准包含的射线数字成像检测系统及其内容。②数字成像与胶片照相像质评价指标的区别。③数字成像与胶片照相像质的等效问题。④数字成像技术应用应关注的其它问题。

  10. A digital subtraction radiography based tool for periodontal bone resorption analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schiabel, Homero; Rodrigues, Eveline B., E-mail: homero@sc.usp.br [University of Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Dept. of Electrical Engineering; Rubira-Bullen, Izabel R.F. [University of Sao Paulo (USP), Bauru, SP (Brazil). Bauru Dentistry School

    2011-07-01

    The aim of this paper was to describe an aided diagnosis scheme for periodontal bone resorption so that the dentist can make an early diagnosis of the periodontal disease and establish the best treatment plan to increase the success of healing. Three ways of displaying the results are provided: qualitative, simple quantitative and colored-percentage quantitative views. A total of 72 pairs of in vitro radiographic images were used. The main procedure registers the images perspective projection aimed to align them in rotation and translation, and is followed by the application of a contrast correction technique. The results from the subtraction were evaluated firstly by the comparison between the actual and the digital sizes corresponding to the holes made by drills in phantoms. The mean error was 4.2%. The method was also applied to actual tooth radiographic images and could detect clearly the effect of treatment of periodontal diseases. It is dependent on the reproducibility of the process of radiographs acquisition and digitization, but the calculated mean error allows to conclude its better efficacy compared to usual procedures in this field. (author)

  11. Effect of changing the kilovoltage peak on radiographic caries assessment in digital and conventional radiography

    Energy Technology Data Exchange (ETDEWEB)

    Zayet, Mohamed Khalifa; Helaly, Yara Rabee; Eiid, Salma Belal [Dept. of Oral Radiology, Faculty of Oral and Dental Medicine, Cairo University, Cairo (Egypt)

    2014-09-15

    This study aimed to investigate the effect of changing the kilovoltage peak (kVp) on the radiographic assessment of dental caries. Seventy-five extracted posterior teeth with proximal caries or apparently sound proximal surfaces were radiographed with conventional E-speed films and a photostimulable phosphor system using 60 kVp and 70 kVp for the caries assessment. The images were evaluated by three oral radiologists and compared with the results of the stereomicroscope analysis. No statistically significant difference was found between 60 kVp and 70 kVp for the caries detection, determination of caries extension into dentin, and caries severity in either the conventional or the digital images. Good to very good inter-observer and intra-observer agreements were found for both kilovoltage values on the conventional and digital images. Changing the kilovoltage between 60 kVp and 70 kVp had no obvious effect on the detection of proximal caries or determination of its extension or severity.

  12. Patient-specific stopping power calibration for proton therapy planning based on single-detector proton radiography.

    Science.gov (United States)

    Doolan, P J; Testa, M; Sharp, G; Bentefour, E H; Royle, G; Lu, H-M

    2015-03-07

    A simple robust optimizer has been developed that can produce patient-specific calibration curves to convert x-ray computed tomography (CT) numbers to relative stopping powers (HU-RSPs) for proton therapy treatment planning. The difference between a digitally reconstructed radiograph water-equivalent path length (DRRWEPL) map through the x-ray CT dataset and a proton radiograph (set as the ground truth) is minimized by optimizing the HU-RSP calibration curve. The function of the optimizer is validated with synthetic datasets that contain no noise and its robustness is shown against CT noise. Application of the procedure is then demonstrated on a plastic and a real tissue phantom, with proton radiographs produced using a single detector. The mean errors using generic/optimized calibration curves between the DRRWEPL map and the proton radiograph were 1.8/0.4% for a plastic phantom and -2.1/ - 0.2% for a real tissue phantom. It was then demonstrated that these optimized calibration curves offer a better prediction of the water equivalent path length at a therapeutic depth. We believe that these promising results are suggestive that a single proton radiograph could be used to generate a patient-specific calibration curve as part of the current proton treatment planning workflow.

  13. Three-detector setup for PAL spectrometer based on DRS4 waveform digitizing board

    Institute of Scientific and Technical Information of China (English)

    安然; 丛龙翰; 叶邦角; 郭智荣; 陈祥磊; 代传波; 郭晓彬; 龚玉巍; 李清华; 任才; 刘艳芬; 郭俊清

    2015-01-01

    A digital three-detector positron lifetime spectrometer was developed. It consists of a DRS4 waveform digi-tizing board and three LaBr3 scintillation detectors coupled to XP2020Q photomultiplier tubes. DRS4 waveform digitizing allows data sampling at up to 5 GSPS with high amplitude resolution, with good time scale linearity and stability. In the triple-coincidence, the new system could reach a 195 ps time resolution, which is better than the conventional analog apparatus with the same detectors. This spectrometer can be applied to the other scintillation timing measurements with picoseconds accuracy.

  14. Use of cone-beam tomography and digital subtraction radiography for diagnosis and evaluation of traumatized teeth treated with endodontic surgery and MTA. A case report.

    Science.gov (United States)

    de Carvalho, Fabíola Bastos; Gonçalves, Paloma Souza; Lima, Regina Karla de Pontes; Guerreiro-Tanomaru, Juliane Maria; Rasquin, Luis Cardoso; Tanomaru-Filho, Mário

    2013-10-01

    The aim of this paper was to report the diagnosis and evaluation of periradicular bone repair by using computed tomography and digital subtraction radiography in an endodontic surgery case treated with mineral trioxide aggregate (MTA). The patient had local swelling and fistula 7 years after trauma in the upper jaw. Periapical lesion on tooth #12 and root resorption of tooth #11 were detected radiographically. Endodontic therapy and placement of intracanal medication were carried out. After 3 months, with no improvement in the clinical signs and symptoms, computed tomography was performed, showing extensive apical bone resorption on tooth #12 and dental resorption promoting communication of the root canal with the periodontium of tooth #11. The patient was referred to endodontic surgery. After surgery and postoperative periods of 15, 30, 60, 90, and 120 days, standardized radiographs were taken, digitized, and subjected to digital subtraction of the images using Adobe Photoshop CS software. Four years later, a cone-beam computed tomography was performed, showing bone repair and absence of root resorption at tooth #11. In this clinical case, digital subtraction radiography was effective for early detection of new bone formation and evolution of repair. © 2011 John Wiley & Sons A/S.

  15. The influence of liquid crystal display monitors on observer performance for the detection of interstitial lung markings on both storage phosphor and flat-panel-detector chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Yon Mi [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-dong, Kangnam-ku, Seoul 135-710 (Korea, Republic of); Department of Radiology, Gachon University Gil Hospital, 1198, Guwol-dong, Namdong-gu, Incheon 405-760 (Korea, Republic of); Chung, Myung Jin [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-dong, Kangnam-ku, Seoul 135-710 (Korea, Republic of)], E-mail: mj1.chung@samsung.com; Lee, Kyung Soo [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, 50, Ilwon-dong, Kangnam-ku, Seoul 135-710 (Korea, Republic of); Choe, Bong-Keun [Department of Preventive Medicine, School of Medicine, Kyunghee University, Seoul (Korea, Republic of)

    2010-04-15

    Purpose: To compare observer performance with a flat-panel liquid crystal display (LCD) monitor and with a high-resolution gray-scale cathode ray tube (CRT) monitor in the detection of interstitial lung markings using a silicon flat-panel-detector direct radiography (DR) and storage phosphor computed radiography (CR) in a clinical setting. Materials and methods: We displayed 39 sets of posteroanterior chest radiographs from the patients who were suspected of interstitial lung disease. Each sets consisted of DR, CR and thin-section CT as the reference standard. Image identities were masked, randomly sorted, and displayed on both five mega pixel (2048 x 2560 x 8 bits) LCD and CRT monitors. Ten radiologists independently rated their confidence in detection for the presence of linear opacities in the four fields of the lungs; right upper, left upper, right lower, and left lower quadrant. Performance of a total 6240 (39 sets x 2 detector systems x 2 monitor system x 4 fields x 10 observers) observations was analyzed by multi-reader multi-case receiver operating characteristic (ROC) analysis. Differences between monitor systems in combinations of detector systems were compared using ANOVA and paired-samples t-test. Results: Area under curves (AUC) for the presence of linear opacities measured by ROC analysis was higher on the LCDs than CRTs without statistical significance (p = 0.082). AUC was significantly higher on the DR systems than CR systems (p = 0.006). AUC was significantly higher on the LCDs than CRTs for DR systems (p = 0.039) but not different for CR systems (p = 0.301). Conclusion: In clinical conditions, performance of the LCD monitor appears to be better for detecting interstitial lung markings when interfaced with DR systems.

  16. Low power adder based digital filter for QRS detector.

    Science.gov (United States)

    Murali, L; Chitra, D; Manigandan, T

    2014-01-01

    Most of the Biomedical applications use dedicated processors for the implementation of complex signal processing. Among them, sensor network is also a type, which has the constraint of low power consumption. Since the processing elements are the most copiously used operations in the signal processors, the power consumption of this has the major impact on the system level application. In this paper, we introduce low power concept of transistor stacking to reduce leakage power; and new architectures based on stacking to implement the full adder and its significance at the digital filter level for QRS detector are implemented. The proposed concept has lesser leakage power at the adder as well as filter level with trade-off in other quality metrics of the design. This enabled the design to be dealt with as the low-power corner and can be made adaptable to any level of hierarchical abstractions as per the requirement of the application. The proposed architectures are designed, modeled at RTL level using the Verilog-HDL, and synthesized in Synopsys Design Compiler by mapping the design to 65 nm technology library standard cells.

  17. Optimized digital filtering techniques for radiation detection with HPGe detectors

    CERN Document Server

    Salathe, M

    2015-01-01

    This paper describes state-of-the-art digital filtering techniques that are part of the tool kit GEANA which is used as a fast automatic data validation tool for the GERDA experiment. The discussed filters include a novel, nonlinear correction method for ballistic deficits, which is combined with one of three shaping filters: the pseudo-Gaussian, a modified trapezoidal, or a modified cusp filter. The performance of the filters is demonstrated using a 762 g high purity germanium detector that measures gamma-ray lines from radioactive sources in an energy range between 59 and 2615 keV. The modified cusp filter was found to be most optimal for individual gamma-ray lines. Furthermore, it was observed, that even though, the shaping time that minimizes the energy resolution is energy dependent, the loss in resolution by using a constant shaping time over the entire energy range is small, i.e. less than 32 eV for the pseudo-Gaussian filter. This together with good energy resolutions, e.g. 1.59 keV at 1333 keV, this ...

  18. Evaluation of the Patient Effective Dose in Whole Spine Scanography Based on the Automatic Image Pasting Method for Digital Radiography.

    Science.gov (United States)

    Kim, Jung-Su; Yoon, Sang-Wook; Seo, Deok-Nam; Nam, So-Ra; Kim, Jung-Min

    2016-01-01

    Whole spine scanography (WSS) is a radiologic examination that requires whole body X-ray exposure. Consequently, the amount of patient radiation exposure is higher than the radiation dose following routine X-ray examination. Several studies have evaluated the patient effective dose (ED) following single exposure film-screen WSS. The objective of this study was to evaluate patient ED during WSS, based on the automatic image pasting method for multiple exposure digital radiography (APMDR). Further, the calculated EDs were compared with the results of previous studies involving single exposure film-screen WSS. We evaluated the ED of 50 consecutive patients (M:F = 28:22) who underwent WSS using APMDR. The anterior-posterior (AP) and lateral (LAT) projection EDs were evaluated based on the Monte Carlo simulation. Using APMDR, the mean number of exposures was 6.1 for AP and 6.5 for LAT projections. LAT projections required more exposures (6.55%) than AP projections. The mean ED was 0.6276 mSv (AP) and 0.6716 mSv (LAT). The mean ED for LAT projections was 0.6061 mSv in automatic exposure control (AEC) and 0.7694 mSv in manual mode. The relationship between dose-area-product (DAP) and ED revealed a proportional correlation (AP, R(2) = 0.943; LAT, R(2) = 0.773). Compared to prior research involving single exposure screen-film WSS, the patient ED following WSS using APMDR was lower on AP than on LAT projections. Despite multiple exposures, ED control is more effective if WSS is performed using APMDR in the AEC mode.

  19. Dose optimization for different medical imaging tasks from exposure index, exposure control factor, and MAS in digital radiography.

    Science.gov (United States)

    Zhang, Menglong; Zhao, Bin; Wang, Yaying; Chen, Weixia; Hou, Lixia

    2012-09-01

    In radiographic examination, not all medical imaging tasks require the same level of image quality or diagnostic information. Criteria should be established for different imaging tasks to avoid excessive doses where there is no clear net benefit in the diagnosis or the image quality. An exposure index provided by manufacturers would be a useful tool for this purpose. This study aims to establish an optimum exposure index to be used as a guideline for clinical imaging tasks to minimize radiation exposure for chest digital radiography. A three-level classification of image quality (high, medium, and low) for chest imaging tasks was carried out. An anthropomorphic phantom was employed to establish minimum exposure index and exposure (mAs) for clinical imaging task type I (corresponding to high image quality). The exposures of medium and low quality images derived from it. Thirty patients were exposed consecutively with these optimized exposure factors, and clinical tasks were considered, while another 30 patients were exposed with the exposure factors routinely used in practice. Image quality was assessed objectively by a consensus panel. The optimized exposure provided a significant reduction of the mean exposure index from 1,556 to 1,207 (p < 0.0001) and mean patient's entrance surface dose from 0.168 mGy to 0.092 mGy (p < 0.0001). The results show that a clinical-task-determined radiographic procedure is more conducive to radiation protection of patients. In this study, the posteroanterior chest imaging examination was chosen as an example. This procedure can also apply to other body parts and views.

  20. Detection method of proximal caries using line profile in digital intra-oral radiography

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yong Suk; Kim, Gyu Tae; Hwang, Eui Hwan; Lee, Min Ja; Choi, Sam Jin; Park, Hun Kuk [Department of Oral and Maxillofacial Radiology, School of Dentistry and Institute of Oral Biology, Kyung Hee University, Seoul (Korea, Republic of); Park, Jeong Hoon [Department of Biomedical Engineering, College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    2009-12-15

    The purpose of this study was to investigate how to detect proximal caries using line profile and validate linear measurements of proximal caries lesions by basic digital manipulation of radiographic images. The X-ray images of control group (15) and caries teeth (15) from patients were used. For each image, the line profile at the proximal caries-susceptible zone was calculated. To evaluate the contrast as a function of line profile to detect proximal caries, a difference coefficient (D) that indicates the relative difference between caries and sound dentin or intact enamel was measured. Mean values of D were 0.0354 {+-} 0.0155 in non-caries and 0.2632 {+-} 0.0982 in caries (p<0.001). The mean values of caries group were higher than non-caries group and there was correlation between proximal dental caries and D. It is demonstrated that the mean value of D from caries group was higher than that of control group. From the result, values of D possess great potentiality as a new detection parameter for proximal dental caries.

  1. Detection of tuberculosis using digital chest radiography: automated reading vs. interpretation by clinical officers.

    Science.gov (United States)

    Maduskar, P; Muyoyeta, M; Ayles, H; Hogeweg, L; Peters-Bax, L; van Ginneken, B

    2013-12-01

    A busy urban health centre in Lusaka, Zambia. To compare the accuracy of automated reading (CAD4TB) with the interpretation of digital chest radiograph (CXR) by clinical officers for the detection of tuberculosis (TB). A retrospective analysis was performed on 161 subjects enrolled in a TB specimen bank study. CXRs were analysed using CAD4TB, which computed an image abnormality score (0-100). Four clinical officers scored the CXRs for abnormalities consistent with TB. We compared the automated readings and the readings by clinical officers against the bacteriological and radiological results used as reference. We report here the area under the receiver operating characteristic curve (AUC) and kappa (κ) statistics. Of 161 enrolled subjects, 97 had bacteriologically confirmed TB and 120 had abnormal CXR. The AUCs for CAD4TB and the clinical officers were respectively 0.73 and 0.65-0.75 in comparison with the bacteriological reference, and 0.91 and 0.89-0.94 in comparison with the radiological reference. P values indicated no significant differences, except for one clinical officer who performed significantly worse than CAD4TB (P < 0.05) using the bacteriological reference. κ values for CAD4TB and clinical officers with radiological reference were respectively 0.61 and 0.49-0.67. CXR assessment using CAD4TB and by clinical officers is comparable. CAD4TB has potential as a point-of-care test and for the automated identification of subjects who require further examinations.

  2. Digital reconstructed radiography with multiple color image overlay for image-guided radiotherapy.

    Science.gov (United States)

    Yoshino, Shinichi; Miki, Kentaro; Sakata, Kozo; Nakayama, Yuko; Shibayama, Kouichi; Mori, Shinichiro

    2015-05-01

    Registration of patient anatomical structures to the reference position is a basic part of the patient set-up procedure. Registration of anatomical structures between the site of beam entrance on the patient surface and the distal target position is particularly important. Here, to improve patient positional accuracy during set-up for particle beam treatment, we propose a new visualization methodology using digitally reconstructed radiographs (DRRs), overlaid DRRs, and evaluation of overlaid DRR images in clinical cases. The overlaid method overlays two DRR images in different colors by dividing the CT image into two CT sections at the distal edge of the target along the treatment beam direction. Since our hospital uses fixed beam ports, the treatment beam angles for this study were set at 0 and 90 degrees. The DRR calculation direction was from the X-ray tube to the imaging device, and set to 180/270 degrees and 135/225 degrees, based on the installation of our X-ray imaging system. Original and overlaid DRRs were calculated using CT data for two patients, one with a parotid gland tumor and the other with prostate cancer. The original and overlaid DRR images were compared. Since the overlaid DRR image was completely separated into two regions when the DRR calculation angle was the same as the treatment beam angle, the overlaid DRR visualization technique was able to provide rich information for aiding recognition of the relationship between anatomical structures and the target position. This method will also be useful in patient set-up procedures for fixed irradiation ports.

  3. Determining MTF of digital detector system with Monte Carlo simulation

    Science.gov (United States)

    Jeong, Eun Seon; Lee, Hyung Won; Nam, Sang Hee

    2005-04-01

    We have designed a detector based on a-Se(amorphous Selenium) and done simulation the detector with Monte Carlo method. We will apply the cascaded linear system theory to determine the MTF for whole detector system. For direct comparison with experiment, we have simulated 139um pixel pitch and used simulated X-ray tube spectrum.

  4. A novel demodulator/detector for digital and analog signals on LMR channels

    Science.gov (United States)

    Saulnier, Gary J.; Rafferty, William

    1990-01-01

    The design, implementation, and performance of an all-digital demodulator/detector suitable for differentially encoded phase-shift keying (DPSK), continuous-phase frequency-shift keying (CPFSK), frequency-shift keying (FSK), and analog FM are discussed. In this demodulator/detector, two detectors, one noncoherent and another differentially coherent, operate simultaneously to provide data detection and automatic frequency control (AFC). Test results indicate that the system provides improved performance over the conventional analog quadrature detector for two-period raised-cosine (2RC) CPFSK modulation in additive white Gaussian noise (AWGN) and Rayleigh fading channels. Being all-digital, the demodulator/detector is well suited for integrated circuit implementation. In addition, the system performs as well as the analog quadrature detector for analog FM voice transmissions, thereby maintaining full compatibility with analog land mobile radio (LMR) transmissions.

  5. X-ray digital industrial radiography (DIR) for local liquid velocity (VLL) measurement in trickle bed reactors (TBRs): Validation of the technique

    Science.gov (United States)

    Mohd Salleh, Khairul Anuar; Rahman, Mohd Fitri Abdul; Lee, Hyoung Koo; Al Dahhan, Muthanna H.

    2014-06-01

    Local liquid velocity measurements in Trickle Bed Reactors (TBRs) are one of the essential components in its hydrodynamic studies. These measurements are used to effectively determine a reactor's operating condition. This study was conducted to validate a newly developed technique that combines Digital Industrial Radiography (DIR) with Particle Tracking Velocimetry (PTV) to measure the Local Liquid Velocity (VLL) inside TBRs. Three millimeter-sized Expanded Polystyrene (EPS) beads were used as packing material. Three validation procedures were designed to test the newly developed technique. All procedures and statistical approaches provided strong evidence that the technique can be used to measure the VLL within TBRs.

  6. Characterization of liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system

    Energy Technology Data Exchange (ETDEWEB)

    Lombigit, L., E-mail: lojius@nm.gov.my; Yussup, N., E-mail: nolida@nm.gov.my; Ibrahim, Maslina Mohd; Rahman, Nur Aira Abd; Rawi, M. Z. M. [Instrumentation Group, Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia)

    2015-04-29

    A digital n/γ pulse shape discrimination (PSD) system is currently under development at Instrumentation and Automation Centre, Malaysian Nuclear Agency. This system aims at simultaneous detection of fast neutron and gamma ray in mixed radiations environment. This work reports the system characterization performed on the liquid scintillation detector (BC-501A) and digital pulse shape discrimination (DPSD) system. The characterization involves measurement of electron light output from the BC-501A detector and energy channels calibration of the pulse height spectra acquired with DPSD system using set of photon reference sources. The main goal of this experiment is to calibrate the ADC channel of our DPSD system, characterized the BC-501 detector and find the position of Compton edge which later could be used as threshold for the n/γ PSD experiment. The detector resolution however is worse as compared to other published data but it is expected as our detector has a smaller active volume.

  7. Real-time radiography

    Energy Technology Data Exchange (ETDEWEB)

    Bossi, R.H.; Oien, C.T.

    1981-02-26

    Real-time radiography is used for imaging both dynamic events and static objects. Fluorescent screens play an important role in converting radiation to light, which is then observed directly or intensified and detected. The radiographic parameters for real-time radiography are similar to conventional film radiography with special emphasis on statistics and magnification. Direct-viewing fluoroscopy uses the human eye as a detector of fluorescent screen light or the light from an intensifier. Remote-viewing systems replace the human observer with a television camera. The remote-viewing systems have many advantages over the direct-viewing conditions such as safety, image enhancement, and the capability to produce permanent records. This report reviews real-time imaging system parameters and components.

  8. Advances in computed radiography systems and their physical imaging characteristics.

    Science.gov (United States)

    Cowen, A R; Davies, A G; Kengyelics, S M

    2007-12-01

    Radiological imaging is progressing towards an all-digital future, across the spectrum of medical imaging techniques. Computed radiography (CR) has provided a ready pathway from screen film to digital radiography and a convenient entry point to PACS. This review briefly revisits the principles of modern CR systems and their physical imaging characteristics. Wide dynamic range and digital image enhancement are well-established benefits of CR, which lend themselves to improved image presentation and reduced rates of repeat exposures. However, in its original form CR offered limited scope for reducing the radiation dose per radiographic exposure, compared with screen film. Recent innovations in CR, including the use of dual-sided image readout and channelled storage phosphor have eased these concerns. For example, introduction of these technologies has improved detective quantum efficiency (DQE) by approximately 50 and 100%, respectively, compared with standard CR. As a result CR currently affords greater scope for reducing patient dose, and provides a more substantive challenge to the new solid-state, flat-panel, digital radiography detectors.

  9. Neutron-induced alpha radiography; Radiografia com particulas alfa induzida por neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Pereira, Marco Antonio Stanojev

    2008-07-01

    A new radiography technique to inspect thin samples was developed. Low energy alpha particles, generated by a boron based screen under thermal neutron irradiation, are used as penetrating radiation. The solid state nuclear track detector CR-39 has been used to register the image. The interaction of the {alpha} - particles with the CR-39 gives rise to damages which under an adequate chemical etching became tracks the basic units forming the image. A digital system was developed for data acquisition and data analysis as well as for image processing. The irradiation and etching conditions to obtain the best radiography are 1,3 hours and 25 minutes at 70 deg C respectively. For such conditions samples having 10 {mu}m in thickness can be inspected with a spatial resolution of 32 {mu}m. The use of the digital system has reduced the time spent for data acquisition and data analysis and has improved the radiography image visualization. Furthermore, by using the digital system, it was possible to study several new parameters regarding the tracks which are very important to understand and study the image formation theory in solid state nuclear track detectors, the one used in this thesis. Some radiography images are also shown which demonstrate the potential of the proposed radiography technique. When compared with the other radiography techniques already in use to inspect thin samples, the present one developed in the present paper allows a smaller time to obtain the image, it is not necessary to handle liquid radioactive substances, the detector is insensitive to {beta}, {gamma}, X-ray and visible light. (author)

  10. Investigation of the thermoluminescent properties of nanosized Alpha-Al{sub 2} O{sub 3} doped with carbon for application in digital radiography

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Edna C., E-mail: edca@cdtn.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Ferraz, Wilmar B.; Faria, Luiz O., E-mail: ferrazw@cdtn.br, E-mail: farialo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    Thermoluminescent (TL) materials are mainly used in personal and environmental dosimetry. In addition to these applications, their use as the sensor element in the manufacturing of digital radiographic films has been investigated. Particularly, there is an interest concerned to the influence of the particle size in the TL response and in the resolution of the digital imaging. Aluminum oxide, or alumina, is a mineral found in the ruby or sapphire form, and may be synthetically produced in the alpha or gamma crystalline phase. Since the 50s, these materials have been studied in their diverse forms and phases. Particularly, the microsized α-Al{sub 2}O{sub 3}:C is considered one of the best TL dosimeter ever produced in the word. In this work, nanosized alumina particulates in the alpha phase, sintered at different temperatures and doped with different concentrations of carbon, were investigated aiming application in industrial radiography and medical diagnosis. The mixture of the oxide powder with the carbon source was pressed and sintered at temperatures of 1740 deg C and 1745 deg C, under reducing atmosphere. For doping purposes we have used two sources of carbon, graphite and high purity polyvinyl acetate (PVA), respectively. During the sintering process, intentional inclusion of oxygen vacancies into the oxide crystal lattice is performed, allowing the inclusion of carbon atoms into the crystal lattice. Among the samples studied, the nanosized alumina doped with 0.01at.% of carbon and sintered at 1745 deg C has shown an excellent thermoluminescent response, with sensitivity higher than that of LiF: Mg, Ti (TLD-100), when irradiated under similar conditions. This is an excellent result, since the material with nanosized particles offers the best features for radiographic image. Thus, it is concluded that the α-Al{sub 2}O{sub 3} doped with 0.01at.% of carbon is a good candidate for use in TL films for application in digital radiography. (author)

  11. Simulation and Digitization of a Gas Electron Multiplier Detector Using Geant4 and an Object-Oriented Digitization Program

    Science.gov (United States)

    McMullen, Timothy; Liyanage, Nilanga; Xiong, Weizhi; Zhao, Zhiwen

    2017-01-01

    Our research has focused on simulating the response of a Gas Electron Multiplier (GEM) detector using computational methods. GEM detectors provide a cost effective solution for radiation detection in high rate environments. A detailed simulation of GEM detector response to radiation is essential for the successful adaption of these detectors to different applications. Using Geant4 Monte Carlo (GEMC), a wrapper around Geant4 which has been successfully used to simulate the Solenoidal Large Intensity Device (SoLID) at Jefferson Lab, we are developing a simulation of a GEM chamber similar to the detectors currently used in our lab. We are also refining an object-oriented digitization program, which translates energy deposition information from GEMC into electronic readout which resembles the readout from our physical detectors. We have run the simulation with beta particles produced by the simulated decay of a 90Sr source, as well as with a simulated bremsstrahlung spectrum. Comparing the simulation data with real GEM data taken under similar conditions is used to refine the simulation parameters. Comparisons between results from the simulations and results from detector tests will be presented.

  12. A DSP equipped digitizer for online analysis of nuclear detector signals

    Energy Technology Data Exchange (ETDEWEB)

    Pasquali, G. [INFN and Department of Physics, University of Florence, Via G.Sansone 1, Sesto Fiorentino 50019 (Italy)]. E-mail: pasquali@fi.infn.it; Ciaranfi, R. [INFN - Sezione di Firenze, Via G.Sansone 1, Sesto Fiorentino 50019 (Italy); Bardelli, L. [INFN and Department of Physics, University of Florence, Via G.Sansone 1, Sesto Fiorentino 50019 (Italy); Bini, M. [INFN and Department of Physics, University of Florence, Via G.Sansone 1, Sesto Fiorentino 50019 (Italy); Boiano, A. [INFN - Sezione di Napoli, Via Cintia, Naples 80126 (Italy); Giannelli, F. [INFN and Department of Physics, University of Florence, Via G.Sansone 1, Sesto Fiorentino 50019 (Italy); Ordine, A. [INFN - Sezione di Napoli, Via Cintia, Naples 80126 (Italy); Poggi, G. [INFN and Department of Physics, University of Florence, Via G.Sansone 1, Sesto Fiorentino 50019 (Italy)

    2007-01-01

    In the framework of the NUCL-EX collaboration, a DSP equipped fast digitizer has been implemented and it has now reached the production stage. Each sampling channel is implemented on a separate daughter-board to be plugged on a VME mother-board. Each channel features a 12-bit, 125 MSamples/s ADC and a Digital Signal Processor (DSP) for online analysis of detector signals. A few algorithms have been written and successfully tested on detectors of different types (scintillators, solid-state, gas-filled), implementing pulse shape discrimination, constant fraction timing, semi-Gaussian shaping, gated integration.

  13. The digital trigger system for the RED-100 detector

    Energy Technology Data Exchange (ETDEWEB)

    Naumov, P. P., E-mail: ddr727@yandex.ru; Akimov, D. Yu.; Belov, V. A.; Bolozdynya, A. I.; Efremenko, Yu. V.; Kaplin, V. A. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute) (Russian Federation)

    2015-12-15

    The system for forming a trigger for the liquid xenon detector RED-100 is developed. The trigger can be generated for all types of events that the detector needs for calibration and data acquisition, including the events with a single electron of ionization. In the system, a mechanism of event detection is implemented according to which the timestamp and event type are assigned to each event. The trigger system is required in the systems searching for rare events to select and keep only the necessary information from the ADC array. The specifications and implementation of the trigger unit which provides a high efficiency of response even to low-energy events are considered.

  14. Three Dimensional Digital Image Processing using Edge Detectors

    Directory of Open Access Journals (Sweden)

    John Schmeelk

    2005-11-01

    Full Text Available This paper provides an introduction to three dimensional image edge detection and its relationship to partial derivatives, convolutions and wavelets. We are especially addressing the notion of edge detection because it has far reaching applications in all areas of research to include medical research. A patient can be diagnosed as having an aneurysm by studying an angiogram. An angiogram is the visual view of the blood vessels whereby the edges are highlighted through the implementation of edge detectors. This process is completed through convolution, wavelets and matrix techniques. Some illustrations included will be vertical, horizontal, Sobel and wavelet edge detectors.

  15. Local liquid velocity measurement in trickle bed reactors (TBRs) using the x-ray digital industrial radiography (DIR) technique

    Science.gov (United States)

    Anuar Mohd Salleh, Khairul; Lee, Hyoung Koo; Al-Dahhan, Muthanna H.

    2014-01-01

    This work describes the development of a new technique to measure local liquid velocity (VLL) for multiphase flows in trickle bed reactors (TBRs) (gas-liquid-solid system). In the studied TBR, the liquid phase is represented by water, gas by air and 3 mm expanded polystyrene beads as the solid packing. Three different superficial liquid velocities (VSL) and a constant superficial gas velocity (VSG) were used in the packed bed with an internal diameter of 4.25 cm. While the liquid is moving into the packed bed, tracking particles of 106-125 μm diameter (16.45% difference) are injected. The movement of the tracking particles is monitored and digitally recorded by a complementary metal-oxide-semiconductor detector. In this experiment, x-rays were used as the radiation source. Four replications were made with fresh packing. Comparable observations can be found from other published techniques (i.e. magnetic resonance imaging). Results from this study indicate that, at VSL = 0.13 cm s-1, the measured VLL can reach up to 51 times that of its VSL, while for VSL = 0.27 cm s-1, the measured VLL reached up to 35 times higher than the VSL and for VSL = 0.39 cm s-1, the VLL reached up to 39.8 times higher than its VSL. Through statistical analysis, the implementation of such a method is found to be reproducible throughout the experiments. The mean per cent difference in the measured VLL was 10% and 5% for lower implemented VSL of 0.13 and 0.27 cm s-1, respectively. At higher VSL (0.39 cm s-1), the particle tracer was greatly distributed and carried away by the high liquid flow rate. The variance or the range of the measured VLL does not vary for all replications in every VSL, which confirms the reproducibility of the experimental measurements, regardless of the VSL.

  16. X-ray light valve (XLV): a novel detectors' technology for digital mammography

    Science.gov (United States)

    Marcovici, Sorin; Sukhovatkin, Vlad; Oakham, Peter

    2014-03-01

    A novel method, based on X-ray Light Valve (XLV) technology, is proposed for making good image quality yet inexpensive flat panel detectors for digital mammography. The digital mammography markets, particularly in the developing countries, demand quality machines at substantially lower prices than the ones available today. Continuous pressure is applied on x-ray detectors' manufacturers to reduce the flat panel detectors' prices. XLV presents a unique opportunity to achieve the needed price - performance characteristics for direct conversion, x-ray detectors. The XLV based detectors combine the proven, superior, spatial resolution of a-Se with the simplicity and low cost of liquid crystals and optical scanning. The x-ray quanta absorbed by a 200 μm a-Se produce electron - hole pairs that move under an electric field to the top and bottom of a-Se layer. This 2D charge distribution creates at the interface with the liquid crystals a continuous (analog) charge image corresponding to the impinging radiation's information. Under the influence of local electrical charges next to them, the liquid crystals twist proportionally to the charges and vary their light reflectivity. A scanning light source illuminates the liquid crystals while an associated, pixilated photo-detector, having a 42 μm pixel size, captures the light reflected by the liquid crystals and converts it in16 bit words that are transmitted to the machine for image processing and display. The paper will describe a novel XLV, 25 cm x 30 cm, flat panel detector structure and its underlying physics as well as its preliminary performance measured on several engineering prototypes. In particular, the paper will present the results of measuring XLV detectors' DQE, MTF, dynamic range, low contrast resolution and dynamic behavior. Finally, the paper will introduce the new, low cost, XLV detector based, digital mammography machine under development at XLV Diagnostics Inc.

  17. Characterizing X-ray detectors for prototype digital breast tomosynthesis systems

    Science.gov (United States)

    Kim, Y.-s.; Park, H.-s.; Park, S.-J.; Choi, S.; Lee, H.; Lee, D.; Choi, Y.-W.; Kim, H.-J.

    2016-03-01

    The digital breast tomosynthesis (DBT) system is a newly developed 3-D imaging technique that overcomes the tissue superposition problems of conventional mammography. Therefore, it produces fewer false positives. In DBT system, several parameters are involved in image acquisition, including geometric components. A series of projections should be acquired at low exposure. This makes the system strongly dependent on the detector's characteristic performance. This study compares two types of x-ray detectors developed by the Korea Electrotechnology Research Institute (KERI). The first prototype DBT system has a CsI (Tl) scintillator/CMOS based flat panel digital detector (2923 MAM, Dexela Ltd.), with a pixel size of 0.0748 mm. The second uses a-Se based direct conversion full field detector (AXS 2430, analogic) with a pixel size of 0.085 mm. The geometry of both systems is same, with a focal spot 665.8 mm from the detector, and a center of rotation 33 mm above the detector surface. The systems were compared with regard to modulation transfer function (MTF), normalized noise power spectrum (NNPS), detective quantum efficiency (DQE) and a new metric, the relative object detectability (ROD). The ROD quantifies the relative performance of each detector at detecting specified objects. The system response function demonstrated excellent linearity (R2>0.99). The CMOS-based detector had a high sensitivity, while the Anrad detector had a large dynamic range. The higher MTF and noise power spectrum (NPS) values were measured using an Anrad detector. The maximum DQE value of the Dexela detector was higher than that of the Anrad detector with a low exposure level, considering one projection exposure for tomosynthesis. Overall, the Dexela detector performed better than did the Anrad detector with regard to the simulated Al wires, spheres, test objects of ROD with low exposure level. In this study, we compared the newly developed prototype DBT system with two different types of x

  18. Effects of irradiation of energetic heavy ions on digital pulse shape analysis with silicon detectors

    Science.gov (United States)

    Barlini, S.; Carboni, S.; Bardelli, L.; Le Neindre, N.; Bini, M.; Borderie, B.; Bougault, R.; Casini, G.; Edelbruck, P.; Olmi, A.; Pasquali, G.; Poggi, G.; Rivet, M. F.; Stefanini, A. A.; Baiocco, G.; Berjillos, R.; Bonnet, E.; Bruno, M.; Chbihi, A.; Cruceru, I.; Degerlier, M.; Dueñas, J. A.; Galichet, E.; Gramegna, F.; Kordyasz, A.; Kozik, T.; Kravchuk, V. L.; Lopez, O.; Marchi, T.; Martel, I.; Morelli, L.; Parlog, M.; Piantelli, S.; Petrascu, H.; Rosato, E.; Seredov, V.; Vient, E.; Vigilante, M.; Fazia Collaboration

    2013-04-01

    The next generation of 4π detector arrays for heavy ion studies will largely use Pulse Shape Analysis to push the performance of silicon detectors with respect to ion identification. Energy resolution and pulse shape identification capabilities of silicon detectors under prolonged irradiation by energetic heavy ions have thus become a major issue. In this framework, we have studied the effects of irradiation by energetic heavy ions on the response of neutron transmutation doped (nTD) silicon detectors. Sizeable effects on the amplitude and the risetime of the charge signal have been found for detectors irradiated with large fluences of stopped heavy ions, while much weaker effects were observed by punching-through ions. The robustness of ion identification based on digital pulse shape techniques has been evaluated.

  19. Defect size dependent contrast reduction and additional blurring from scattered radiation reduce the quality of radiological images. A comparison of films and digital detectors; Fehlergroessenabhaengige Kontrastreduktion und zusaetzliche Unschaerfe durch Streustrahlung reduzieren die Bildqualitaet radiologischer Abbildungen. Film und digitale Detektoren im Vergleich

    Energy Technology Data Exchange (ETDEWEB)

    Ewert, Uwe; Beckmann, Joerg; Bellon, Carsten; Jaenisch, Gerd-Ruediger; Zscherpel, Uwe; Jechow, Mirko [Bundesanstalt fuer Materialforschung und -pruefung (BAM), Berlin (Germany); Grosser, Anja [Technische Fachhochschule Wildau (Germany)

    2008-07-01

    Radiographic image quality in its classic definition depends on contrast, noise (in films: grain as an equivalent to image noise), and blur. These parameters are normally measured with the aid of image quality test specimens. Scattered radiation will always reduce the quality of radiographic imaging. The various influencing parameters are analysed with a view to the available techniques like film radiograpy, computerised radiography with storage foils, and digital radiography using digital detector arrays (DDA). Textbooks and standards (e.g. ASTM E 1000) define the scattering ratio k and various contrasts, e.g. specific and relative contrast in radiographic imaging. In the case of digital media, additional arameters are introduced like the signal-noise ratio SNR and the contrast-noise ratio CNR; the inverse CNR corresponds to the well-known contrast sensitivity typically measured with the aid of image quality test specimens. In project ''FilmFree'', the optimum conditions for film substitution are investigated. The influence of scattered radiation from the measured object and the detector on image quality were investigated. Numeric modelling (Monte-Carlo modelling) is used for defining the scattered radiation and the primary radiation emitted by the object. The scattered radiation from the object and the detector generates an image that is superposed on the primary image and is more blurred than the latter, especially at higher radiation energies. The scattered radiation images have blurs in the cm range. This is an undesirable effect both in classic film radiography and in digital radiography and computed tomography. Further, an additional contrast reduction resulting from scattered radiation was found when the detector is close to the object (contact technique). This effect depends on the defect size, the distance between detector and object, and the intermediate filtering. [German] Die radiographische Bildqualitaet in ihrer klassischen

  20. A digitally calibrated CMOS RMS power detector for RF automatic gain control

    Institute of Scientific and Technical Information of China (English)

    Yan Taotao; Wang Hui; Li Jinbo; Zhou Jianjun

    2013-01-01

    This paper presents the design and implementation of a digitally calibrated CMOS wideband radio frequency (RF) root-mean-square (RMS) power detector for high accuracy RF automatic gain control (AGC).The proposed RMS power detector demonstrates accurate power detection in the presence of process,supply voltage,and temperature (PVT) variations by employing a digital calibration scheme.It also consumes low power and occupies a small chip area.The measurement results show that the scheme improves the accuracy of the detector to better than 0.3 dB over the PVT variations and wide operating frequency range from 0.2 to 0.8 GHz.Implemented in a 0.18 μm CMOS process and occupying a small die area of 263 × 214 μm2,the proposed digitally calibrated CMOS RMS power detector only consumes 1.6 mA in power detection mode and 2.1 mA in digital calibration mode from a 1.8 V supply voltage.

  1. Analysis of Silicon Photomultiplier Detector Waveforms from Cosmic Rays using Digital Signal Processing Techniques

    Science.gov (United States)

    Castro, Juan; Zavala, Favian; Niduaza, Rexavalmar; Wedel, Zachary; Fan, Sewan; Ritt, Stefan; Fatuzzo, Laura

    2014-03-01

    Silicon photomultiplier detectors exhibit high gain, low operating voltage, are insensitive to magnetic fields, and can detect light at the single photon level, making them very attractive for applications in fields such as particle physics, astrophysics, and medical physics. However, they exhibit effects that may prevent their optimal operation, including thermally induced high dark count rate, after pulse effects, and cross talk produced from photons in nearby pixels. In this presentation, we describe our coincidence setup using two scintillator pads and a Hamamatsu multipixel photon counter (MPPC) to gather cosmic ray produced signal pulses, and our methods of analysis for the detector waveforms. In particular, we discuss our methods of digitization, software implementation of low pass and Gaussian type filters, and the application of a domino ring sampler (DRS4) digitizing board to obtain signal waveforms to determine the operating characteristics for these detectors. Department of Education grant number P031S90007.

  2. Neutron Radiography

    Science.gov (United States)

    Heller, A. K.; Brenizer, J. S.

    Neutron radiography and its related two-dimensional (2D) neutron imaging techniques have been established as invaluable nondestructive inspection methods and quantitative measurement tools. They have been used in a wide variety of applications ranging from inspection of aircraft engine turbine blades to study of two-phase fluid flow in operating proton exchange membrane fuel cells. Neutron radiography is similar to X-ray radiography in that the method produces a 2D attenuation map of neutron radiation that has penetrated the object being examined. However, the images produced differ and are often complementary due to the differences between X-ray and neutron interaction mechanisms. The uses and types of 2D neutron imaging have expanded over the past 15 years as a result of advances in imaging technology and improvements in neutron generators/sources and computers. Still, high-intensity sources such as those from reactors and spallation neutron sources, together with conventional film radiography, remain the mainstay of high-resolution, large field-of-view neutron imaging. This chapter presents a summary of the history, methods, and related variations of neutron radiography techniques.

  3. Digital discrimination of neutrons and gamma-rays in organic scintillation detectors using moment analysis

    Science.gov (United States)

    Xie, Xufei; Zhang, Xing; Yuan, Xi; Chen, Jinxiang; Li, Xiangqing; Zhang, Guohui; Fan, Tieshuan; Yuan, Guoliang; Yang, Jinwei; Yang, Qingwei

    2012-09-01

    Digital discrimination of neutron and gamma-ray events in an organic scintillator has been investigated by moment analysis. Signals induced by an americium-beryllium (Am/Be) isotropic neutron source in a stilbene crystal detector have been sampled with a flash analogue-to-digital converter (ADC) of 1 GSamples/s sampling rate and 10-bit vertical resolution. Neutrons and gamma-rays have been successfully discriminated with a threshold corresponding to gamma-ray energy about 217 keV. Moment analysis has also been verified against the results assessed by a time-of-flight (TOF) measurement. It is shown that the classification of neutrons and gamma-rays afforded by moment analysis is consistent with that achieved by digital TOF measurement. This method has been applied to analyze the data acquired from the stilbene crystal detector in mixed radiation field of the HL-2A tokamak deuterium plasma discharges and the results are described.

  4. Application of neural networks to digital pulse shape analysis for an array of silicon strip detectors

    Energy Technology Data Exchange (ETDEWEB)

    Flores, J.L. [Dpto de Ingeniería Eléctrica y Térmica, Universidad de Huelva (Spain); Martel, I. [Dpto de Física Aplicada, Universidad de Huelva (Spain); CERN, ISOLDE, CH 1211 Geneva, 23 (Switzerland); Jiménez, R. [Dpto de Ingeniería Electrónica, Sist. Informáticos y Automática, Universidad de Huelva (Spain); Galán, J., E-mail: jgalan@diesia.uhu.es [Dpto de Ingeniería Electrónica, Sist. Informáticos y Automática, Universidad de Huelva (Spain); Salmerón, P. [Dpto de Ingeniería Eléctrica y Térmica, Universidad de Huelva (Spain)

    2016-09-11

    The new generation of nuclear physics detectors that used to study nuclear reactions is considering the use of digital pulse shape analysis techniques (DPSA) to obtain the (A,Z) values of the reaction products impinging in solid state detectors. This technique can be an important tool for selecting the relevant reaction channels at the HYDE (HYbrid DEtector ball array) silicon array foreseen for the Low Energy Branch of the FAIR facility (Darmstadt, Germany). In this work we study the feasibility of using artificial neural networks (ANNs) for particle identification with silicon detectors. Multilayer Perceptron networks were trained and tested with recent experimental data, showing excellent identification capabilities with signals of several isotopes ranging from {sup 12}C up to {sup 84}Kr, yielding higher discrimination rates than any other previously reported.

  5. Application of neural networks to digital pulse shape analysis for an array of silicon strip detectors

    Science.gov (United States)

    Flores, J. L.; Martel, I.; Jiménez, R.; Galán, J.; Salmerón, P.

    2016-09-01

    The new generation of nuclear physics detectors that used to study nuclear reactions is considering the use of digital pulse shape analysis techniques (DPSA) to obtain the (A,Z) values of the reaction products impinging in solid state detectors. This technique can be an important tool for selecting the relevant reaction channels at the HYDE (HYbrid DEtector ball array) silicon array foreseen for the Low Energy Branch of the FAIR facility (Darmstadt, Germany). In this work we study the feasibility of using artificial neural networks (ANNs) for particle identification with silicon detectors. Multilayer Perceptron networks were trained and tested with recent experimental data, showing excellent identification capabilities with signals of several isotopes ranging from 12C up to 84Kr, yielding higher discrimination rates than any other previously reported.

  6. Investigation of optimum anti-scatter grid selection for digital radiography: physical imaging properties and detectability of low-contrast signals.

    Science.gov (United States)

    Tanaka, Nobukazu; Naka, Kentaro; Saito, Aya; Morishita, Junji; Toyofuku, Fukai; Ohki, Masafumi; Higashida, Yoshiharu

    2013-01-01

    Our aim in this study was to evaluate the effect of the grid variations on the imaging performance for a computed radiographic system under identical exposure condition. Digital radiographies using a 20-cm Lucite phantom were performed without grid and with grid ratios of 5:1, 8:1, 10:1, 12:1, and 14:1. The scatter fraction, the incident dose to the image receptor, the Wiener spectrum (WS), and the noise-equivalent quanta (NEQ) were measured. Visibility of low-contrast signals was evaluated using a contrast-detail phantom. The scatter fractions decreased considerably with an increase in the grid ratio. On the other hand, the WSs were increased (the noise property deteriorated) as the grid ratio increased due to a decreased incident dose to the image receptor under the identical exposure condition. The NEQs were improved as the grid ratio increased. The high grid ratios provided higher low-contrast detectability compared to the low grid ratios. Our results indicated that the removal of scattered radiation was very effective in improvement of the NEQ in the digital system under the identical exposure condition.

  7. 数字化的低张双对比造影对早期食道癌的诊断价值%Diagnostic Value of Hypotonic Double Contrast Digital Radiography Examination in Early Esophageal Cancer

    Institute of Scientific and Technical Information of China (English)

    林少波; 吴维颖; 李淳南; 林集荣; 陈滨柱; 温奇敏

    2014-01-01

    Objective:To study the diagnostic value of hypotonic double contrast digital radiography ex-amination to early esophageal cancer. Method: The digital radiography examination image and pathological data of 72 cases with early esophageal cancer diagnosed in our hospital were reviewed .Then compare it with the traditional single contrast esophageal radiography examination .Result:Esophageal wall relaxation degree slightly worse , 34 cases;the local mucosal disruption and destruction , 64 cases;small filling defect , 22 ca-ses;small niche, 21 cases.The traditional single contrast esophageal radiography examination in 18.6 cases, accounting for 18.1%;the hypotonic double contrast esophageal digital radiography examination in 68 cases, accounting for 94.4%.Conclusion:Hypotonic double contrast digital radiography examination has important value in the diagnosis of early esophageal cancer , reflected in the discovery , locating , qualitative aspects .It is obviously superior to the traditional single contrast radiography examination .%目的:探讨数字化的低张双对比造影对早期食道癌的诊断价值。方法:回顾性分析我院确诊72例早期食道癌的数字化低张双对比造影的影像资料,并与传统单对比食道造影进行比较。结果:数字化低张双对比造影对72例早期食道癌的X线表现分析:食道管壁舒张度稍差,34例;局部粘膜中断破坏,64例;小充盈缺损,22例;小龛影,21例。结论:数字化的低张双对比造影对早期食道癌的发现、定位、定性具有重要诊断价值,明显优于传统单对比造影。

  8. Optimization of the NSCL Digital Data Acquisition System For Use With Fast Scintillator Detectors

    Science.gov (United States)

    Prokop, Christopher; Liddick, Sean; Larson, Nicole; Suchyta, Scott; Tompkins, Jeromy

    2013-10-01

    The Digital Data Acquisition System (DDAS) at the National Superconducting Cyclotron Laboratory is composed of several XIA Pixie-16 modules utilizing 12-bit digitizers sampling at 100 Mega-Samples-Per-Second. DDAS has been applied to fast organic and inorganic scintillator detectors intended for level lifetime and neutron time-of-flight studies, for which the time resolution is critical. Simultaneous high-resolution time and energy determination using online digital CFD and trapezoidal filtering algorithms is non-intuitive due to the short characteristic rise and decay times of the signals with respect to the sampling time of the digitizers. A new technique has been developed to identify the optimum filter parameters to maximize the time and energy resolution of each detector signal in an offline analysis. The parameters were subsequently verified online and have resulted in a 30% improvement in the measured time resolution between two LaBr3 detectors. Additional results and applications of the technique will be presented.

  9. Digital column readout architectures for hybrid pixel detector readout chips

    CERN Document Server

    Poikela, T; Westerlund, T; Buytaert, J; Campbell, M; De Gaspari, M; Llopart, X; Wyllie, K; Gromov, V; Kluit, R; van Beuzekom, M; Zappon, F; Zivkovic, V; Brezina, C; Desch, K; Fu, Y; Kruth, A

    2014-01-01

    In this paper, two digital column architectures suitable for sparse readout of data from a pixel matrix in trigger-less applications are presented. Each architecture reads out a pixel matrix of 256 x 256 pixels with a pixel pitch of 55 µm. The first architecture has been implemented in the Timepix3 chip, and this is presented together with initial measurements. Simulation results and measured data are compared. The second architecture has been designed for Velopix, a readout chip planned for the LHCb VELO upgrade. Unlike Timepix3, this has to be tolerant to radiation-induced single-event effects. Results from post-layout simulations are shown with the circuit architectures.

  10. Quantitative film radiography

    Energy Technology Data Exchange (ETDEWEB)

    Devine, G.; Dobie, D.; Fugina, J.; Hernandez, J.; Logan, C.; Mohr, P.; Moss, R.; Schumacher, B.; Updike, E.; Weirup, D.

    1991-02-26

    We have developed a system of quantitative radiography in order to produce quantitative images displaying homogeneity of parts. The materials that we characterize are synthetic composites and may contain important subtle density variations not discernible by examining a raw film x-radiograph. In order to quantitatively interpret film radiographs, it is necessary to digitize, interpret, and display the images. Our integrated system of quantitative radiography displays accurate, high-resolution pseudo-color images in units of density. We characterize approximately 10,000 parts per year in hundreds of different configurations and compositions with this system. This report discusses: the method; film processor monitoring and control; verifying film and processor performance; and correction of scatter effects.

  11. Performance evaluation of a computed radiography system

    Energy Technology Data Exchange (ETDEWEB)

    Roussilhe, J.; Fallet, E. [Carestream Health France, 71 - Chalon/Saone (France); Mango, St.A. [Carestream Health, Inc. Rochester, New York (United States)

    2007-07-01

    Computed radiography (CR) standards have been formalized and published in Europe and in the US. The CR system classification is defined in those standards by - minimum normalized signal-to-noise ratio (SNRN), and - maximum basic spatial resolution (SRb). Both the signal-to-noise ratio (SNR) and the contrast sensitivity of a CR system depend on the dose (exposure time and conditions) at the detector. Because of their wide dynamic range, the same storage phosphor imaging plate can qualify for all six CR system classes. The exposure characteristics from 30 to 450 kV, the contrast sensitivity, and the spatial resolution of the KODAK INDUSTREX CR Digital System have been thoroughly evaluated. This paper will present some of the factors that determine the system's spatial resolution performance. (authors)

  12. Digital and Analog Electronics for an autonomous, deep-sea, Gamma Ray Burst Neutrino prototype detector

    Science.gov (United States)

    Manolopoulos, K.; Belias, A.; Markou, C.; Rapidis, P.; Kappos, E.

    2016-04-01

    GRBNeT is a Gamma Ray Burst Neutrino Telescope made of autonomously operated arrays of deep-sea light detectors, anchored to the sea-bed without any cabled connection to the shore. This paper presents the digital and analog electronics that we have designed and developed for the GRBNeT prototype. We describe the requirements for these electronics and present their design and functionality. We present low-power analog electronics for the PMTs utilized in the GRBNeT prototype and the FPGA based digital system for data selection and storage. We conclude with preliminary performance measurements of the electronics systems for the GRBNeT prototype.

  13. Digital signal processing for CdTe detectors using VXIbus data collection systems

    Energy Technology Data Exchange (ETDEWEB)

    Fukuda, Daiji; Takahashi, Hiroyuki; Kurahashi, Tomohiko; Iguchi, Tetsuo; Nakazawa, Masaharu

    1996-07-01

    Recently fast signal digitizing technique has been developed, and signal waveforms with very short time periods can be obtained. In this paper, we analyzed each measured pulse which was digitized by an apparatus of this kind, and tried to improve an energy resolution of a CdTe semiconductor detector. The result of the energy resolution for {sup 137}Cs 662 keV photopeak was 13 keV. Also, we developed a fast data collection system based on VXIbus standard, and the counting rate on this system was obtained about 50 counts per second. (author)

  14. Measurements of timing resolution of ultra-fast silicon detectors with the SAMPIC waveform digitizer

    Science.gov (United States)

    Breton, D.; De Cacqueray, V.; Delagnes, E.; Grabas, H.; Maalmi, J.; Minafra, N.; Royon, C.; Saimpert, M.

    2016-11-01

    The SAMpler for PICosecond time (SAMPIC) chip has been designed by a collaboration including CEA/IRFU/SEDI, Saclay and CNRS/LAL/SERDI, Orsay. It benefits from both the quick response of a time to digital converter and the versatility of a waveform digitizer to perform accurate timing measurements. Thanks to the sampled signals, smart algorithms making best use of the pulse shape can be used to improve time resolution. A software framework has been developed to analyse the SAMPIC output data and extract timing information by using either a constant fraction discriminator or a fast cross-correlation algorithm. SAMPIC timing capabilities together with the software framework have been tested using pulses generated by a signal generator or by a silicon detector illuminated by a pulsed infrared laser. Under these ideal experimental conditions, the SAMPIC chip has proven to be capable of timing resolutions down to 4 ps with synthesized signals and 40 ps with silicon detector signals.

  15. Comparing Eruption Space of the Lower Third Molar in Unerupted and Erupted Teeth via Digital Anoramic Radiography in Patients Referring to Yazd Dental College during 2011-13

    Directory of Open Access Journals (Sweden)

    F Ezoddini Ardakani

    2014-08-01

    Full Text Available Introduction: The aim of this study is to determine and compare the eruption space of unerupted and erupted third molars by the means of digital panoramic radiography in patients referring to Yazd dental college during 2011-2013. Methods: In this cross-sectional descriptive study, 150 archived digital panoramic radiographies in radiology department were evaluated with Romexis software under the standard circumstances. The radiographic pictures belonged to 73 men and 77 women with the average age of 21.18±1.67 years. In patients with erupted third molars as well as unerupted third molars (mesio-angular and vertical, several parameters were examined including: angle of the tooth axis of second and third molar, Gonial angle, the width of third molar, retro-molar space and its ratio to the width of third molar, the development stage of third molar root as well as the distance between the center of ramus and the most distal point of second molar. The data related to age, sex and the eruption situation of lower third molar- unerupted or erupted- were extracted from the patient’s log. The data were analyzed by SPSS (ver.17 via applying descriptive tests and T-test. Results: A statistically significant difference was observed between the two groups in regard with the average angle between second and third molar, the mean space of retro-molar and its ratio to the width of third molar as well as the mean distance between centers of ramus and second molar (P=0.0001. Moreover, no significant difference was observed in Gonial angle mean (P=0.213 and the width of third molar (P.value=0.348. Conclusion: Increasing the angle between second and third molar as well as inadequate space of retro-molar can lead to impaction of lower third molar, but the width of third molar and the Gonial angle size did not reveal any significant role in determination of impaction or eruption of third molar.

  16. Direct conversion Si and CdZnTe detectors for digital mammography

    CERN Document Server

    Yin Shi Shi; Maeding, D; Mainprize, J; Mawdsley, G; Yaffe, M J; Gordon, E E; Hamilton, W J

    2000-01-01

    Hybrid pixel detector arrays that convert X-rays directly into charge signals are under development at NOVA for application to digital mammography. This technology also has wide application possibilities in other fields of radiology or in industrial imaging, nondestructive evaluation (NDE) and nondestructive inspection (NDI). These detectors have potentially superior properties compared to either emulsion-based film-screen systems which has nonlinear response to X-rays, or phosphor-based detectors in which there is an intermediate step of X-ray to light photon conversion (Feig and Yaffe, Radiol. Clinics North America 33 (1995) 1205-1230). Potential advantages of direct conversion detectors are high quantum efficiencies (QE) of 98% or higher (for 0.3 mm thick CdZnTe detector with 20 keV X-rays), improved contrast, high sensitivity and low intrinsic noise. These factors are expected to contribute to high detective quantum efficiency (DQE). The prototype hybrid pixel detector developed has 50x50 mu m pixel size,...

  17. Analysis of image quality according to BMI of digital chest radiography: Focusing on bureau of radiological health evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Seong Jin [Gammaknife center, Inje University Haeundae Paik Hospital, Busan (Korea, Republic of); Im, In Chul [Dept. of Radiological Science, Dongeui University, Busan (Korea, Republic of); Cho, Ji Hwan [Dept. of Health Care Clinic, Inje University Busan Paik Hospital, Busan (Korea, Republic of)

    2017-03-15

    Visual evaluation of chest radiograph images is the most practical and effective method. This study compared the Body Mass Index, waist circumference, and mAs with chest radiographs of 351 women. The Bureau of Radiological Health method was used to evaluate the image quality of chest X-ray images by anatomical and physical methods. The average age of the subjects was 30.17±4.73 and the average waist circumference was 66.91±4.67 cm. The mean Body Mass Index value was 20.21±2.23, the mean value of mAs was 3.04±0.78, and the mean value of Bureau of Radiological Health was 79.83±8.45. When the Body Mass Index value increased, waist circumference and mAs mean value increased. The mean value of Body Mass Index was statistically significant(p<0.05) in Group 4 compared to Groups 1 and 2, with increasing Body Mass Index. Exposure control of the automatic exposure control system is considered to be well performed according to body thickness or Body Mass Index at the time of chest radiography. As the Body Mass Index increases, the thickness of the body increases and the breast thickness of the woman also increases. Therefore, it is considered that the exposure amount is changed by the automatic exposure control device to affect the image quality.

  18. Methodology for the construction of a physical phantom for quality control of images in digital radiography; Metodologia para a construcao de um fantoma fisico para controle de qualidade de imagens em radiografia digital

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Tayline T.; Vieira, Jose Wilson, E-mail: aylinetyene@hotmail.com, E-mail: jose.wilson59@uol.com.br [Instituto Federal de Educacao, Ciencia e Tecnologia de Pernambuco (IFFPE), Recife, PE (Brazil); Oliveira, Alex Cristovao H. de; Lima, Fernando R. de Andrade, E-mail: oliveira_ach@yahoo.com, E-mail: falima@cnen.gov.br [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil); Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2013-07-01

    The advancement of technology in recent years has provided the production of increasingly sophisticated devices, aiming to acquire medical images with high technical level and also facilitate the operational readiness of the equipment. In order to ensure the most accurate diagnosis with minimum dose without exposing patients to obtain data and verify the performance of a radiographic system for quality control purposes we use the so-called phantoms. Phantoms are physical or computational models used to simulate the transport of ionizing radiation, their interactions in the tissues of the human body and evaluate the deposition of energy. Besides, they are made from materials with behavior similar to human tissues when exposed to ionizing radiation - the so-called tissue-equivalent materials. This paper describes the construction of a physical phantom that allows the execution of the main acceptance tests of the quality control protocols in digital radiography.

  19. Digital luminescence radiography (DLR) in the diagnosis of traumatic bone lesions. Digitale Lumineszenzradiographie (DLR) zur Skelettdiagnostik in der Traumatologie

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, R.D.; Buddenbrock, B.; Voss, M.; Bosch, E.; Loehr, E. (Essen Univ. (Gesamthochschule) (Germany, F.R.). Roentgendiagnostisches Zentralinstitut); Kock, H.J.; Schmidt, G.; Schmit-Neuerburg, K.P. (Essen Univ. (Gesamthochschule) (Germany, F.R.). Abt. fuer Unfallchirurgie); Hirche, H. (Essen Univ. (Gesamthochschule) (Germany, F.R.). Inst. fuer Medizinische Informatik und Biomathematik)

    1991-06-01

    170 patients who had suffered trauma to bones or soft tissues were examined by a digital and a conventional film/screen technique. In addition to 'standard' and edge-enhanced images, post-processing was carried out and compared with conventional radiographs. The 'standard' digital images are inferior to film images, but edge-enhanced images showed definite advantages for demonstrating soft tissues. Evaluation of osteo-synthetic material is limited by the creation of artifacts. Recognition of detail can be significantly improved by using post-processing with optimed parameters. (orig./GDG).

  20. SAPHIRE: A New Flat-Panel Digital Mammography Detector With Avalanche Photoconductor and High-Resolution Field Emitter Readout

    Science.gov (United States)

    2006-06-01

    AD_________________ Award Number: W81XWH-04-1-0554 TITLE: SAPHIRE : A New Flat-Panel Digital... SAPHIRE : A New Flat-Panel Digital Mammography Detector with Avalanche Photoconductor and High-Resolution Field Emitter Readout 5b. GRANT NUMBER w81xwh-04...CsI), and form a charge image that is read out by a high-resolution field emitter array (FEA). We call the proposed detector SAPHIRE (Scintillator

  1. Digital pulse-timing technique for the neutron detector array NEDA

    Energy Technology Data Exchange (ETDEWEB)

    Modamio, V., E-mail: victor.modamio@lnl.infn.it [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, I-35020 Legnaro (Italy); Valiente-Dobón, J.J. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, I-35020 Legnaro (Italy); Jaworski, G. [Faculty of Physics, Warsaw University of Technology, 00-662 Warszawa (Poland); Heavy Ion Laboratory, University of Warsaw, 02-093 Warszawa (Poland); Hüyük, T. [Instituto de Física Corpuscular, CSIC-Universitat de València, E-46980 Valencia (Spain); Triossi, A. [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, I-35020 Legnaro (Italy); Egea, J. [Instituto de Física Corpuscular, CSIC-Universitat de València, E-46980 Valencia (Spain); Department of Electronic Engineering, Universitat de València, E-46100 Burjassot (Spain); Di Nitto, A. [Johannes Gutenberg-Universität Mainz, D-55099 Mainz (Germany); Söderström, P.-A. [RIKEN Nishina Center, 2-1 Hirosawa, Wako-shi, 351-0198 Saitama (Japan); Agramunt Ros, J. [Instituto de Física Corpuscular, CSIC-Universitat de València, E-46980 Valencia (Spain); Angelis, G. de [Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali di Legnaro, I-35020 Legnaro (Italy); France, G. de [GANIL, CEA/DSAM and CNRS/IN2P3, F-14076 Caen (France); Erduran, M.N. [Faculty of Engineering and Natural Sciences, Istanbul Sabahattin Zaim University, 34303 Istanbul (Turkey); and others

    2015-03-01

    A new digital pulse-timing algorithm, to be used with the future neutron detector array NEDA, has been developed and tested. The time resolution of four 5 in. diameter photomultiplier tubes (XP4512, R4144, R11833-100, and ET9390-kb), coupled to a cylindrical 5 in. by 5 in. BC501A liquid scintillator detector was measured by employing digital sampling electronics and a constant fraction discriminator (CFD) algorithm. The zero crossing of the CFD algorithm was obtained with a cubic spline interpolation, which was continuous up to the second derivative. The performance of the algorithm was studied at sampling rates of 500 MS/s and 200 MS/s. The time resolution obtained with the digital electronics was compared to the values acquired with a standard analog CFD. The result of this comparison shows that the time resolution from the analog and the digital measurements at 500 MS/s and at 200 MS/s are within 15% for all the tested photomultiplier tubes.

  2. Comparison of chest radiography, chest digital tomosynthesis and low dose MDCT to detect small ground-glass opacity nodules: an anthropomorphic chest phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Doo, Kyung Won; Kang, Eun-Young; Yong, Hwan Seok [Korea University Guro Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Ham, Soo-Youn [Korea University Anam Hospital, Korea University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Lee, Ki Yeol; Choo, Ji Yung [Korea University Ansan Hospital, Korea University College of Medicine, Department of Radiology, Ansan (Korea, Republic of)

    2014-12-15

    The purpose of this study was to evaluate the diagnostic performance of chest radiography (CXR), chest digital tomosynthesis (DT) and low dose multidetector computed tomography (LDCT) for the detection of small pulmonary ground-glass opacity (GGO) nodules, using an anthropomorphic chest phantom. Artificial pulmonary nodules were placed in a phantom and a total of 40 samples of different nodule settings underwent CXR, DT and LDCT. The images were randomly read by three experienced chest radiologists. Free-response receiver-operating characteristics (FROC) were used. The figures of merit for the FROC curves averaged for the three observers were 0.41, 0.37 and 0.76 for CXR, DT and LDCT, respectively. FROC analyses revealed significantly better performance of LDCT over CXR or DT for the detection of GGO nodules (P < 0.05). The difference in detectability between CXR and DT was not statistically significant (P = 0.73). The diagnostic performance of DT for the detection of pulmonary small GGO nodules was not significantly different from that of CXR, but LDCT performed significantly better than both CXR and DT. DT is not a suitable alternative to CT for small GGO nodule detection, and LDCT remains the method of choice for this purpose. (orig.)

  3. Digital pulse processing and electronic noise analysis for improving energy resolutions in planar TlBr detectors

    Energy Technology Data Exchange (ETDEWEB)

    Tada, Tsutomu, E-mail: tada.t@cyric.tohoku.ac.j [Cyclotron and Radioisotope Center, Tohoku University, 6-3 Aza-Aoba, Aramaki, Aoba-ku, Sendai, Miyagi 980-8579 (Japan); Hitomi, Keitaro [Cyclotron and Radioisotope Center, Tohoku University, 6-3 Aza-Aoba, Aramaki, Aoba-ku, Sendai, Miyagi 980-8579 (Japan); Tanaka, Tomonobu [Divisions of Electronics, Graduate School of Engineering, Tohoku Institute of Technology, 35-1 Yagiyama, Kasumi-cho, Taihakuku, Sendai, Miyagi 982-8577 (Japan); Wu, Yan; Kim, Seong-Yun; Yamazaki, Hiromichi [Cyclotron and Radioisotope Center, Tohoku University, 6-3 Aza-Aoba, Aramaki, Aoba-ku, Sendai, Miyagi 980-8579 (Japan); Ishii, Keizo [Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, 6-6-1 Aza-Aoba, Aramaki, Aoba-ku, Sendai, Miyagi 980-8579 (Japan)

    2011-05-11

    Digital pulse processing and electronic noise analysis are proposed for improving energy resolution in planar thallium bromide (TlBr) detectors. An energy resolution of 5.8% FWHM at 662 keV was obtained from a 0.5 mm thick planar TlBr detector at room temperature using a digitizer with a sampling rate of 100 MS/s and 8 bit resolution. The electronic noise in the detector-preamplifier system was measured as a function of pulse shaping time in order to investigate the optimum shaping time for the detector. The depth of interaction (DOI) in TlBr detectors for incident gamma-rays was determined by taking the ratio of pulse heights for fast-shaped to slow-shaped signals. FWHM energy resolution of the detector was improved from 5.8% to 4.2% by implementing depth correction and by using the obtained optimum shaping time.

  4. Feasibility of Amorphous Selenium Based Photon Counting Detectors for Digital Breast Tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Chen, J.; O' Connor, P.; Lehnert, J., De Geronimo, G., Dolazza, E., Tousignant, O., Laperriere, L., Greenspan, J., Zhao, W.

    2009-02-27

    Amorphous selenium (a-Se) has been incorporated successfully in direct conversion flat panel x-ray detectors, and has demonstrated superior image quality in screening mammography and digital breast tomosynthesis (DBT) under energy integration mode. The present work explores the potential of a-Se for photon counting detectors in DBT. We investigated major factors contributing to the variation in the charge collected by a pixel upon absorption of each x-ray photon. These factors included x-ray photon interaction, detector geometry, charge transport, and the pulse shaping and noise properties of the photon counting readout circuit. Experimental measurements were performed on a linear array test structure constructed by evaporating an a-Se layer onto an array of 100 {mu}m pitch strip electrodes, which are connected to a 32 channel low noise photon counting integrated circuit. The measured pulse height spectrum (PHS) under polychromatic xray exposure was interpreted quantitatively using the factors identified. Based on the understanding of a-Se photon counting performance, design parameters were proposed for a 2D detector with high quantum efficiency and count rate that could meet the requirements of photon counting detector for DBT.

  5. Quality control of virtual wedge in a linear electron accelerator with a computerized radiography system (CR); Control de calidad de la cuna virtual en un acelerador lineal de electrones mediante un sistema de radiografia competerizada (CR)

    Energy Technology Data Exchange (ETDEWEB)

    Ordiales, J. M.; Alvarez, F. J.; Falero, B.

    2011-07-01

    For quality control of the virtual wedge there are several systems on the market as arrays of detectors or ionization chambers, linear or 2D configuration, radiochromic films or digital imaging systems incorporated in electron linear accelerators (ALE ). The present work aims at implementing a system of Computed Radiography (CR) for a routine check of the virtual wedge.

  6. A PET detector prototype based on digital SiPMs and GAGG scintillators.

    Science.gov (United States)

    Schneider, Florian R; Shimazoe, Kenji; Somlai-Schweiger, Ian; Ziegler, Sibylle I

    2015-02-21

    Silicon Photomultipliers (SiPM) are interesting light sensors for Positron Emission Tomography (PET). The detector signal of analog SiPMs is the total charge of all fired cells. Energy and time information have to be determined with dedicated readout electronics. Philips Digital Photon Counting has developed a SiPM with added electronics on cell level delivering a digital value of the time stamp and number of fired cells. These so called Digital Photon Counters (DPC) are fully digital devices. In this study, the feasibility of using DPCs in combination with LYSO (Lutetium Yttrium Oxyorthosilicate) and GAGG (Gadolinium Aluminum Gallium Garnet) scintillators for PET is tested. Each DPC module has 64 channels with 3.2 × 3.8775 mm(2), comprising 3200 cells each. GAGG is a recently developed scintillator (Zeff = 54, 6.63 g cm(-3), 520 nm peak emission, 46 000 photons MeV(-1), 88 ns (92%) and 230 ns (8%) decay times, non-hygroscopic, chemically and mechanically stable). Individual crystals of 2 × 2 × 6 mm(3) were coupled onto each DPC pixel. LYSO coupled to the DPC results in a coincidence time resolution (CTR) of 171 ps FWHM and an energy resolution of 12.6% FWHM at 511 keV. Using GAGG, coincidence timing is 310 ps FWHM and energy resolution is 8.5% FWHM. A PET detector prototype with 2 DPCs equipped with a GAGG array matching the pixel size (3.2 × 3.8775 × 8 mm(3)) was assembled. To emulate a ring of 10 modules, objects are rotated in the field of view. CTR of the PET is 619 ps and energy resolution is 9.2% FWHM. The iterative MLEM reconstruction is based on system matrices calculated with an analytical detector response function model. A phantom with rods of different diameters filled with (18)F was used for tomographic tests.

  7. A PET detector prototype based on digital SiPMs and GAGG scintillators

    Science.gov (United States)

    Schneider, Florian R.; Shimazoe, Kenji; Somlai-Schweiger, Ian; Ziegler, Sibylle I.

    2015-02-01

    Silicon Photomultipliers (SiPM) are interesting light sensors for Positron Emission Tomography (PET). The detector signal of analog SiPMs is the total charge of all fired cells. Energy and time information have to be determined with dedicated readout electronics. Philips Digital Photon Counting has developed a SiPM with added electronics on cell level delivering a digital value of the time stamp and number of fired cells. These so called Digital Photon Counters (DPC) are fully digital devices. In this study, the feasibility of using DPCs in combination with LYSO (Lutetium Yttrium Oxyorthosilicate) and GAGG (Gadolinium Aluminum Gallium Garnet) scintillators for PET is tested. Each DPC module has 64 channels with 3.2 × 3.8775 mm2, comprising 3200 cells each. GAGG is a recently developed scintillator (Zeff = 54, 6.63 g cm-3, 520 nm peak emission, 46 000 photons MeV-1, 88 ns (92%) and 230 ns (8%) decay times, non-hygroscopic, chemically and mechanically stable). Individual crystals of 2 × 2 × 6 mm3 were coupled onto each DPC pixel. LYSO coupled to the DPC results in a coincidence time resolution (CTR) of 171 ps FWHM and an energy resolution of 12.6% FWHM at 511 keV. Using GAGG, coincidence timing is 310 ps FWHM and energy resolution is 8.5% FWHM. A PET detector prototype with 2 DPCs equipped with a GAGG array matching the pixel size (3.2 × 3.8775 × 8 mm3) was assembled. To emulate a ring of 10 modules, objects are rotated in the field of view. CTR of the PET is 619 ps and energy resolution is 9.2% FWHM. The iterative MLEM reconstruction is based on system matrices calculated with an analytical detector response function model. A phantom with rods of different diameters filled with 18F was used for tomographic tests.

  8. Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis

    Energy Technology Data Exchange (ETDEWEB)

    Peer, Siegfried; Giacomuzzi, Salvatore M.; Peer, Regina; Gassner, Eva; Steingruber, Iris; Jaschke, Werner [Department of Radiology, University Hospital, Anichstrasse 35, 6020 Innsbruck (Austria)

    2003-02-01

    With the introduction of digital flat-panel detector systems into clinical practice, the still unresolved question of resolution requirements for picture archiving communication system (PACS) workstation monitors has gained new momentum. This contrast detail analysis was thus performed to define the differences in observer performance in the detection of small low-contrast objects on clinical 1K and 2K monitor workstations. Images of the CDRAD 2.0 phantom were acquired at varying exposures on an indirect-type digital flat-panel detector. Three observers evaluated a total of 15 images each with respect to the threshold contrast for each detail size. The numbers of correctly identified objects were determined for all image subsets. No significant difference in the correct detection ratio was detected among the observers; however, the difference between the two types of workstations (1K vs 2K monitors) despite less than 3% was significant at a 95% confidence level. Slight but statistically significant differences exist in the detection of low-contrast nodular details visualized on 1K- and 2K-monitor workstations. Further work is needed to see if this result holds true also for comparison of clinical flat-panel detector images and may, for example, exert an influence on the diagnostic accuracy of chest X-ray readings. (orig.)

  9. Fracture healing: direct magnification versus conventional radiography

    Energy Technology Data Exchange (ETDEWEB)

    Link, T.M. [Dept. of Clinical Radiology, Westfaelische Wilhelms-Univ., Muenster (Germany); Kessler, T. [Dept. of Traumatic and Hand Surgery, Westfaelische Wilhelms-Univ., Muenster (Germany); Lange, T. [Dept. of Clinical Radiology, Westfaelische Wilhelms-Univ., Muenster (Germany); Overbeck, J. [Dept. of Traumatic and Hand Surgery, Westfaelische Wilhelms-Univ., Muenster (Germany); Fiebich, M. [Dept. of Clinical Radiology, Westfaelische Wilhelms-Univ., Muenster (Germany); Peters, P.E. [Dept. of Clinical Radiology, Westfaelische Wilhelms-Univ., Muenster (Germany)

    1994-08-01

    The aim of the study was to evaluate the potential of magnification radiography in diagnosing fracture healing and assessing its complications. Seventy-three patients with fractures or who had undergone osteotomy were radiographed with both conventional (non-magnified) and magnification (5-fold) techniques. Since 10 patients were radiographed twice and 1 three times, 83 radiographs using each technique were obtained. All radiographs were analysed and the findings correlated with the patients` follow-up studies. The microfocal X-ray unit used for magnification radiography had a focal spot size of 20-130 {mu}m. As an imaging system, digital luminescence radiography was employed with magnification, while normal film-screen systems were used with conventional radiography. Magnification radiography proved superior to conventional radiography in 47% of cases: endosteal and periosteal callus formations were seen earlier and better in 26 cases, and osseous union could be evaluated with greater certainty in 33 cases. In 49% of cases magnification radiography was equal and in 4% inferior to conventional radiography. Additionally an ``inter-observer analysis`` was carried out. Anatomical and pathological structures were classified into one of four grades. Results were significantly (P < 0.01) better using magnification radiography. We conclude that the magnification technique is a good method for monitoring fracture healing in its early stages. (orig.)

  10. Digital data acquisition for the Low Energy Neutron Detector Array (LENDA)

    Energy Technology Data Exchange (ETDEWEB)

    Lipschutz, S., E-mail: lipschutz@nscl.msu.edu [Department of Physics and Astronomy, Michigan State University, East Lansing, MI (United States); National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Joint Institute for Nuclear Astrophysics Center for the Evolution of the Elements, Michigan State University, East Lansing, MI (United States); Zegers, R.G.T.; Hill, J. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI (United States); National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Joint Institute for Nuclear Astrophysics Center for the Evolution of the Elements, Michigan State University, East Lansing, MI (United States); Liddick, S.N. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Department of Chemistry, Michigan State University, East Lansing, MI (United States); Noji, S., E-mail: noji@rcnp.osaka-u.ac.jp [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Joint Institute for Nuclear Astrophysics Center for the Evolution of the Elements, Michigan State University, East Lansing, MI (United States); Prokop, C.J. [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Department of Chemistry, Michigan State University, East Lansing, MI (United States); Scott, M. [Department of Physics and Astronomy, Michigan State University, East Lansing, MI (United States); National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Joint Institute for Nuclear Astrophysics Center for the Evolution of the Elements, Michigan State University, East Lansing, MI (United States); Solt, M., E-mail: mrsolt@stanford.edu [National Superconducting Cyclotron Laboratory, East Lansing, MI (United States); Joint Institute for Nuclear Astrophysics Center for the Evolution of the Elements, Michigan State University, East Lansing, MI (United States); Department of Physics, Oakland University, Rochester, MI (United States); and others

    2016-04-11

    A digital data acquisition system (DDAS) has been implemented for the Low Energy Neutron Detector Array (LENDA). LENDA is an array of 24 BC-408 plastic-scintillator bars designed to measure low-energy neutrons with kinetic energies in the range of 100 keV–10 MeV from (p,n)-type charge-exchange reactions. Compared to the previous data acquisition (DAQ) system for LENDA, DDAS offers the possibility to lower the neutron detection threshold, increase the overall neutron-detection efficiency, decrease the dead time of the system, and allow for easy expansion of the array. The system utilized in this work was XIA's Digital Gamma Finder Pixie-16 250 MHz digitizers. A detector-limited timing resolution of 400 ps was achieved for a single LENDA bar. Using DDAS, the neutron detection threshold of the system was reduced compared to the previous analog system, now reaching below 100 keV. The new DAQ system was successfully used in a recent charge-exchange experiment using the {sup 16}C(p,n) reaction at the National Superconducting Cyclotron Laboratory (NSCL).

  11. Digital Data Acquisition For the Low Energy Neutron Detector Array (LENDA)

    CERN Document Server

    Lipschutz, S; Hill, J; Liddick, S N; Noji, S; Prokop, C J; Scott, M; Solt, M; Sullivan, C; Tompkins, J

    2016-01-01

    A digital data acquisition system (DDAS) has been implemented for the Low Energy Neutron Detector Array (LENDA). LENDA is an array of 24 BC-408 plastic-scintillator bars designed to measure low-energy neutrons with kinetic energies in the range of 100 keV to 10 MeV from (p,n)-type charge-exchange reactions. Compared to the previous data acquisition (DAQ) system for LENDA, DDAS offers the possibility to lower the neutron detection threshold, increase the overall neutron-detection efficiency, decrease the dead time of the system, and allow for easy expansion of the array. The system utilized in this work was XIA's Digital Gamma Finder Pixie-16 250 MHz digitizers. A detector-limited timing resolution of 400 ps was achieved for a single LENDA bar. Using DDAS, the neutron detection threshold of the system was reduced compared to the previous analog system, now reaching below 100 keV. The new DAQ system was successfully used in a recent charge-exchange experiment using the $^{16}$C(p,n) reaction at the National Sup...

  12. Estimation of Remnant Dentin Thickness under Proximal Caries Using Digital Bitewing Radiography: An In-Vitro Study

    Directory of Open Access Journals (Sweden)

    Masoomeh Afsa

    2015-12-01

    Full Text Available Objectives: In restorative dentistry, it is essential to estimate the amount of remnant tooth structure after caries removal to make the best treatment plan. The present study was aimed to determine whether there is a correlation between the real thickness of remnant dentin under carious lesion and the radiographical measurement from photostimulable phosphor plates (PSPs. Methods: a whole number of 68 unrestored permanent human molar and premolar teeth with 82 proximal carious surfaces were mounted in an artificial arch. Digital bitewing radiographs with PSPs were taken, carious lesions were removed and radiographic imaging was repeated. Teeth were sectioned mesiodistally in two parts and thickness of remnant tooth structure to pulp was measured. Measurements of remnant dentin under caries from radiographic images and teeth structures were compared. Result: The mean measurements of remnant dentin on primary radiographs were statistically different from the measurements on teeth structures. The mean thickness of remnant dentin on tooth structure was around 30% less than what measured on radiographic image. Conclusion: The real thickness of remnant dentin under caries is about 70% of its thickness measured on digital bitewing radiographs prepared by PSPs as image receptor.

  13. Image performance of a new amorphous selenium flat panel x-ray detector designed for digital breast tomosynthesis

    Science.gov (United States)

    Cheung, L. K.; Jing, Z.; Bogdanovich, S.; Golden, K.; Robinson, S.; Beliaevskaia, E.; Parikh, S.

    2005-04-01

    The purpose of this work is to report the performance of an amorphous selenium (a-Se) based flat-panel x-ray imager under development for application in digital breast tomosynthesis. This detector is designed to perform both in the conventional Full Field Digital Mammography (FFDM) mode and the tomosynthesis mode. The large area 24 x 29 cm detector achieves rapid image acquisition rates of up to 4 frames per second with minimal trapped charge induced effects such as ghost or lag images of previously acquired objects. In this work, a new a-Se/TFT detector layer structure is evaluated. The design uses a top conductive layer in direct contact with the a-Se x-ray detection layer. The simple structure has few layers and minimal hole and electron trapping effects. Prototype detectors were built to investigate the basic image performance of this new a-Se/TFT detector. Image signal generation, image ghosting, image lag, and detector DQE were studied. For digital mammography applications, the residual image ghosting was less than 1% at 30 seconds elapsed time. DQE, measured at a field of 5.15 V/um, showed significantly higher values over previously reported data, especially at low exposure levels. For digital breast tomosynthesis, the image lag at dynamic readout rate was < 0.6 % at 0.5-second elapsed time. A prototype tomosynthesis system is being developed utilizing this new a-Se/TFT detector.

  14. Effects of detector blur and correlated noise on digital breast tomosynthesis reconstruction

    Science.gov (United States)

    Zheng, Jiabei; Fessler, Jeffrey A.; Chan, Heang-Ping

    2017-03-01

    To improve digital breast tomosynthesis (DBT) image quality, we are developing model-based iterative reconstruction methods. We developed the SQS-DBCN algorithm, which incorporated detector blur into the system model and correlation into the noise model under some simplifying assumptions. In this paper, we further improved the regularization in the SQS-DBCN method by incorporating neighbors along the diagonal directions. To further understand the role of the different components in the system model of the SQS-DBCN method, we reconstructed DBT images without modeling either the detector blur or noise correlation for comparison. Visual comparison of the reconstructed images showed that regularizing with diagonal directions reduced artifacts and the noise level. The SQS-DBCN reconstructed images had better image quality than reconstructions without models for detector blur or correlated noise, as indicated by the contrast-to-noise ratios (CNR) of MCs and textural artifacts. These results indicated that regularized DBT reconstruction with detector blur and correlated noise modeling, even with simplifying assumptions, can improve DBT image quality compared to that without system modeling.

  15. Numerical analysis of edge effects in side illuminated strip detectors for digital radiology

    CERN Document Server

    Krizaj, D

    2000-01-01

    The influence of edge defects on side illuminated X-ray strip detectors for digital radiology is investigated by numerical device modeling. By assuming positive fixed oxide charges on side and top surfaces simulations have shown strong curvature of the equipotential lines in the edge region. A fraction of the edge generated current surpasses the edge guard-ring junction and is collected by the readout strips. As a consequence, strips cannot be placed close to the edge of the structure and collection efficiency is reduced. An n-on-n instead of a p-on-n strip detector is proposed enabling collection of edge generated carriers by a very narrow guard-ring junction and placement of the readout strip close to the edge without increase of the strip leakage current.

  16. Radiography with polarised neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, Michael L.

    2010-08-20

    In this thesis I present a new technique for the spatially resolved investigation of the magnetic properties of bulk samples. Standard one dimensional neutron depolarisation analysis is combined with neutron radiography to a method we call Neutron Depolarisation Imaging (NDI). The experimental setup which was installed at the neutron radiography beam line ANTARES at FRM II consists of a double crystal monochromator, neutron polariser, spin flipper, polarisation analyser and a position sensitive CCD detector. A comprehensive discussion of the requirements for these components is given and the limitations of the method are shown. The maximum spatial resolution which can be achieved with a neutron radiography setup is determined by the collimation of the neutron beam and the distance between sample and detector. Different types of polarisers have been tested and their advantages and disadvantages are discussed. A double crystal monochromator and a new type of polariser employing polarising neutron supermirrors based on the principle of an optical periscope were developed and tested during this work. Furthermore, NDI measurements on various samples of the weakly ferromagnetic materials Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al are presented. Neutron depolarisation radiography and tomography measurements were conducted with a spatial resolution as high as 0.3 mm on Pd{sub 1-x}Ni{sub x} and Ni{sub 3}Al samples. The feasibility of NDI experiments under hydrostatic pressures up to 10 kbar was shown on a sample of Ni{sub 3}Al using a modified Cu:Be clamp cell. A decrease of the ordering temperature by 2 K under hydrostatic pressure was determined from the NDI measurements and shows the potential of the method for further high pressure experiments. Additionally a method was developed which in principle allows to obtain the intrinsic dependence of the ordering temperature T{sub C} on the ordered moment Ms from NDI measurements on inhomogeneous samples containing regions with

  17. 1∶1等长骨骼数字X线摄影技术%Study on 1∶1 isometric skeleton digital radiography technique

    Institute of Scientific and Technical Information of China (English)

    陶黎; 彭冈力; 曾勇明; 欧阳祖彬; 王志强; 黄伟

    2014-01-01

    Objective:To explore the application and value before and after prosthetic joint replacement by using 1∶1 isometric skeleton digital radiography technique.Methods:Digital radiography of the patient in standing or supine position was taken in 100 patients with hip joint or knee joint disease with Kodak DR3000 X-ray system.The 1∶1 isometric calibra-tion value of the X-ray film was determined with a metal scale preset experiment in Kodak image processing workstation. Results:The preset length values and the actual measured values had a ratio of 1∶1 .2 .The 1∶1 isometric X-ray films of 100 patients were printed successfully,with about 4% of the error,and to match the clinical needs.Conclusion:The 1∶1 i-sometric X-ray films of hip joint or knee joint in standing or supine position may show the shape changes of human hip joint or knee joint,provide the measurement data for prosthetic joint selection in the surgical strategy,and be used to evaluate the postoperative therapeutic effect.%目的:探讨1∶1等长骨骼数字X线摄影技术及在人工关节置换术术前及术后的应用价值。方法:应用Ko-dak DR3000 X线机对100例髋关节或膝关节疾病患者进行站立负重位或仰卧位摄片,在Kodak 图像处理工作站上经过金属刻度尺预设实验,确定1∶1等长X线片的校准值。结果:预设长度值与实际测量值为1∶1.2的比例关系,100例患者的1∶1等长X线片打印成功,偏差度为0.4%,满足临床要求。结论:髋关节或膝关节站立负重位或仰卧位下的1∶1等长X线片可为骨科医师提供人体髋关节或膝关节的形态变化,为手术方案提供人工关节选择的测量数据,并能对术后疗效进行评估。

  18. Digital and Analog Electronics for an autonomous, deep-sea, Gamma Ray Burst Neutrino prototype detector

    Directory of Open Access Journals (Sweden)

    Manolopoulos K.

    2016-01-01

    Full Text Available GRBNeT is a Gamma Ray Burst Neutrino Telescope made of autonomously operated arrays of deep-sea light detectors, anchored to the sea-bed without any cabled connection to the shore. This paper presents the digital and analog electronics that we have designed and developed for the GRBNeT prototype. We describe the requirements for these electronics and present their design and functionality. We present low-power analog electronics for the PMTs utilized in the GRBNeT prototype and the FPGA based digital system for data selection and storage. We conclude with preliminary performance measurements of the electronics systems for the GRBNeT prototype.

  19. In Vitro Comparison of Cone Beam Computed Tomography with Digital Periapical Radiography for Detection of Vertical Root Fracture in Posterior Teeth

    Science.gov (United States)

    Abdinian, Mehrdad; Razavian, Hamid; Jenabi, Nastaran

    2016-01-01

    Statement of the Problem The diagnosis of vertical root fracture (VRF) is a challenging task. Purpose This in vitro study compared cone beam computed tomography (CBCT) imaging with digital periapical radiography (DPR) made by three different horizontal angels (20°mesial, 0° and 20° distal) for accurate diagnosis of VRF. Materials and Method Among 120 posterior teeth included in this study, 60 were vertically fractured. Fractured and non-fractured teeth were randomly distributed into three groups defined as group 1 with no filling in the root canal, group 2 with gutta-percha in the canal, and group 3 with the intracanal post. All samples were placed in a dry mandible and imaged with CBCT and DPR techniques. Two blind observers investigated the images. Results CBCT had higher sensitivity but lower specificity compared with DPR, except for the intracanal post group in which the sensitivity of DPR was higher; though the chi-square test showed the differences to be statistically insignificant. The sensitivity, specificity, and accuracy of CBCT and DPR were reduced in the cases that gutta-percha or post were present in the canal. Inter-observer agreement was higher for CBCT. A set of three DPRs with different horizontal angels were significantly more sensitive for VRF recognition than a single orthogonal DPR. Conclusion Based on our results, there was no significant difference between CBCT and a set of three DPRs with different angulations for VRF detection in posterior teeth. Therefore, it is suggested to consider DPRs with three different horizontal angels (20°mesial, 0° and 20° distal) for radiographic evaluation before CBCT examination. PMID:27284552

  20. In Vitro Comparison of Cone Beam Computed Tomography with Digital Periapical Radiography for Detection of Vertical Root Fracture in Posterior Teeth

    Directory of Open Access Journals (Sweden)

    Mehrdad Abdinian

    2016-06-01

    Full Text Available Statement of the Problem: The diagnosis of vertical root fracture (VRF is a challenging task. Purpose: This in vitro study compared cone beam computed tomography (CBCT imaging with digital periapical radi-ography (DPR made by three different horizontal angels (20°mesial, 0° and 20° distal for accurate diagnosis of VRF. Materials and Method: Among 120 posterior teeth included in this study, 60 were vertically fractured. Fractured and non-fractured teeth were randomly distributed into three groups defined as group 1 with no filling in the root canal, group 2 with gutta-percha in the canal, and group 3 with the intracanal post. All samples were placed in a dry mandible and imaged with CBCT and DPR techniques. Two blind observers investigated the images. Results: CBCT had higher sensitivity but lower specificity compared with DPR, except for the intracanal post group in which the sensitivity of DPR was higher; though the chi-square test showed the differences to be statistically insignifi-cant. The sensitivity, specificity, and accuracy of CBCT and DPR were reduced in the cases that gutta-percha or post were present in the canal. Inter-observer agreement was higher for CBCT. A set of three DPRs with different horizontal angels were significantly more sensitive for VRF recognition than a single orthogonal DPR. Conclusion: Based on our results, there was no significant difference between CBCT and a set of three DPRs with dif-ferent angulations for VRF detection in posterior teeth. Therefore, it is suggested to consider DPRs with three different horizontal angels (20°mesial, 0° and 20° distal for radiographic evaluation before CBCT examination.

  1. Image quality of a Konica Regius 336 digital system in chest radiography; Qualita' dell'immagine di un sistema digitale Konica Regius 336 per radiologia toracica

    Energy Technology Data Exchange (ETDEWEB)

    Ostinelli, A.; Frigerio, M.; Monti, A.F.; Gelosa, S.; Tognoli, P.; Perniola, N. [Azienda Ospedaliera S. Anna, Como (Italy). Servizio di Fisica Sanitaria; Gozzi, G. [Azienda Ospedaliera S. Anna, Como (Italy). Servizio di Radiologia

    2000-06-01

    Digital radiographic systems permit to optimize execution, depiction and storage of radiological images. Since a Regius 336 digital system (Konica Corp. Tokyo, Japan) devoted to chest radiography Department of S. Anna Hospital in Como, Italy, it was investigated its performance relative to image quality. Konica Regius 336 is a computed radiography system made of a phosphorescence detector plate which is scanned with an infrared semiconductor laser beam. The radiographic image obtained from the detector is subjected to image processing, which allows a stable output and the nonlinear curve typical of conventional radiographic systems. Image quality was assessed based on the following parameters: dose, contrast, noise and spatial resolution. As reference, it was assessed the same parameters on a Cronex 88 analogic chest-changer (DuPont Pharma, North Billerica, Mass, USA). The Regius 336 air kerma values were always higher than the analogic ones (about 10%), both with and without a chest phantom; noise was also greater than in analogic images, sometimes even doubled. The optical densities of a step wedge and the spatial resolution of the digital chest-changer are independent of the X-ray tube voltage consequent to broader optical latitude. Inversely, the analogic images of the wedges show great optical density variability as a function of the X-ray tube voltage (in a range of 2). The modulation transfer functions of the two systems have the same trend. The performance of the Konica Regius 336 is nearly equivalent to that of an analogic system. The main advantages of the digital system are a standard output, lower consumption of radiographic films, higher productiveness and better image quality standard level. [Italian] I sistemi radiografici digitali offrono la possibilita' di ottimizzare l'esecuzione, la visualizzazione e l'archiviazione dell'immagine radiologica. Poiche' presso il Servizio di Radiologia dell'Azienda Ospedaliera S. Anna

  2. Non-destructive imaging of fragments of historical beeswax seals using high-contrast X-ray micro-radiography and micro-tomography with large area photon-counting detector array.

    Science.gov (United States)

    Karch, Jakub; Bartl, Benjamin; Dudak, Jan; Zemlicka, Jan; Krejci, Frantisek

    2016-12-01

    Historical beeswax seals are unique cultural heritage objects. Unfortunately, a number of historical sealing waxes show a porous structure with a strong tendency to stratification and embrittlement, which makes these objects extremely prone to mechanical damage. The understanding of beeswax degradation processes therefore plays an important role in the preservation and consequent treatment of these objects. Conventional methods applied for the investigation of beeswax materials (e.g. gas chromatography) are of a destructive nature or bring only limited information about the sample surface (microscopic techniques). Considering practical limitations of conventional methods and ethical difficulties connected with the sampling of the historical material, radiation imaging methods such as X-ray micro-tomography presents a promising non-destructive tool for the onward scientific research in this field. In this contribution, we present the application of high-contrast X-ray micro-radiography and micro-tomography for the investigation of beeswax seal fragments. The method is based on the application of the large area photon-counting detector recently developed at our institute. The detector combines the advantages of single-photon counting technology with a large field of view. The method, consequently, enables imaging of relatively large objects with high geometrical magnification. In the reconstructed micro-tomographies of investigated historical beeswax seals, we are able to reveal morphological structures such as stratification, micro-cavities and micro-fractures with spatial resolution down to 5μm non-destructively and with high imaging quality. The presented work therefore demonstrates that a combination of state-of-the-art hybrid pixel semiconductor detectors and currently available micro-focus x-ray sources makes it possible to apply X-ray micro-radiography and micro-tomography as a valuable non-destructive tool for volumetric beeswax seal morphological studies

  3. Avaliação dos métodos de mensuração da altura patelar na radiografia digital Assessment of patellar height measurement methods from digital radiography

    Directory of Open Access Journals (Sweden)

    Guilherme Conforto Gracitelli

    2012-04-01

    Full Text Available OBJETIVO: Analisar os métodos mais comuns de medida da altura patelar e o impacto da experiência do observador na correlação com os outros avaliadores utilizando a radiografia digital. MÉTODOS: Sessenta radiografias digitais do joelho na incidência em perfil foram analisadas por quatro observadores, sendo um médico residente do segundo ano de ortopedia (R2, um médico residente do terceiro ano de ortopedia (R3, um ortopedista especialista em joelho (EJ e um radiologista especialista na área musculoesquelética (ER. Os índices estudados foram: Insall-Salvati (IS, Blackburne-Peel (BP, Caton-Deschamps (CD e Insall-Salvati modificado (ISM. Foi calculada a concordância interobservadores por meio do coeficiente de concordância Kappa (κ. RESULTADOS: Os maiores coeficientes de correlação foram obtidos com o método de IS seguido pelo método de CD. A pior correlação foi observada no método de ISM. A maior concordância interobservadores foi obtida entre o ortopedista especialista em joelho e o radiologista especializado na área musculoesquelética nos quatro métodos de aferição utilizados. CONCLUSÃO: Utilizando a radiografia digital, os índices de Insall-Salvati e Caton-Deschamps apresentaram maior concordância interobservadores, sendo esta também influenciada positivamente pela experiência do observador.OBJECTIVE: To analyze the most common methods for measuring patellar height and the impact of observer experience in correlations with the other observers using digital radiography. METHODS: Sixty digital radiographs of the knee in lateral view were analyzed by four observers: a physician in the second year of medical residence in orthopedics (R2; a physician in the third year of medical residence in orthopedics (R3; an orthopedic surgeon who was a specialist in knee surgery (SK; and a radiologist who was a specialist in musculoskeletal radiology (SR. The indices used were: Insall-Salvati (IS, Blackburne-Peel (BP, Caton

  4. Study of the radio-opacity of base and liner dental materials using a digital radiography system.

    Science.gov (United States)

    Lachowski, K M; Botta, S B; Lascala, C A; Matos, A B; Sobral, M A P

    2013-01-01

    This study investigated the radio-opacity of commercially available glass ionomer cements (GICs), flowable resin composites (FRCs) and calcium hydroxide cements (CHCs) and compared this with the radio-opacity of enamel, dentine and aluminium stepwedge. 16 GICs, 8 FRCs and 4 CHCs were analysed. Three sets of three samples were prepared: 1 mm, 2 mm and 3 mm thickness for GIC and FRC and 1 mm thickness for CHC. Specimens of enamel and dentine with the same thicknesses were obtained. As a control, an aluminium stepwedge was used. Radiographs were taken with a digital Kodak RVG 5000 (0.32 s, 30 cm). The images were analysed using the Image Tool(®) program (v. 2.00; The University of Texas Health Science Center, San Antonio, TV) to obtain the mean grey values. Analysis of variance was used to investigate the significance of differences among the groups. For pairwise comparisons, the Tukey test was applied (p < 0.05). The GICs Ionomaster (Wilcos, Petrópolis, Brazil), Maxxion (FGM, Joinville, Brazil), Bioglass R (Biodinâmica, Ibiporã, Brazil), Bioglass F (Biodinâmica), Vidrion R (SS White, Rio de Janerio, Brazil) and Vidrion F (SS White), presented radio-opacity lower than that of dentine. All FRCs and CHCs studied showed radio-opacity higher than that of dentine. Vitro Fil (DFL, Rio de Janeiro, Brazil), Magic Glass (Vigodent, Rio de Janeiro, Brazil), Vitrebond (3M, Sumaré SP, Brazil), Riva Self Cure (SDI, Victoria, Australia), Riva Light Cure (SDI), Fill Magic (Vigodent), Opallis (FGM, Joinville, Brazil), Surefil SDR (Dentsply, Milford, DE), Tetric N (Ivoclar Vivadent, Schaan, Lichtenstein), Tetric (Ivoclar Vivadent), Hydro C (Dentsply, Petrópolis, Brazil), Hydcal (Technew, Madalena, Portugal) and Liner (Vigodent) showed radio-opacity similar to or greater than that of enamel for all thicknesses. The increased thickness of the materials studied increases their radio-opacity. Some commercially available GICs used as a base and liner for restorations

  5. Estimation of the two-dimensional presampled modulation transfer function of digital radiography devices using one-dimensional test objects.

    Science.gov (United States)

    Wells, Jered R; Dobbins, James T

    2012-10-01

    The modulation transfer function (MTF) of medical imaging devices is commonly reported in the form of orthogonal one-dimensional (1D) measurements made near the vertical and horizontal axes with a slit or edge test device. A more complete description is found by measuring the two-dimensional (2D) MTF. Some 2D test devices have been proposed, but there are some issues associated with their use: (1) they are not generally available; (2) they may require many images; (3) the results may have diminished accuracy; and (4) their implementation may be particularly cumbersome. This current work proposes the application of commonly available 1D test devices for practical and accurate estimation of the 2D presampled MTF of digital imaging systems. Theory was developed and applied to ensure adequate fine sampling of the system line spread function for 1D test devices at orientations other than approximately vertical and horizontal. Methods were also derived and tested for slit nonuniformity correction at arbitrary angle. Techniques were validated with experimental measurements at ten angles using an edge test object and three angles using a slit test device on an indirect-detection flat-panel system [GE Revolution XQ∕i (GE Healthcare, Waukesha, WI)]. The 2D MTF was estimated through a simple surface fit with interpolation based on Delaunay triangulation of the 1D edge-based MTF measurements. Validation by synthesis was also performed with simulated images from a hypothetical direct-detection flat-panel device. The 2D MTF derived from physical measurements yielded an average relative precision error of 0.26% for frequencies below the cutoff (2.5 mm(-1)) and approximate circular symmetry at frequencies below 4 mm(-1). While slit analysis generally agreed with the results of edge analysis, the two showed subtle differences at frequencies above 4 mm(-1). Slit measurement near 45° revealed radial asymmetry in the MTF resulting from the square pixel aperture (0.2 mm × 0

  6. Digital signal processing for a thermal neutron detector using ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs

    Science.gov (United States)

    Mosset, J.-B.; Stoykov, A.; Greuter, U.; Hildebrandt, M.; Schlumpf, N.

    2016-07-01

    We present a digital signal processing system based on a photon counting approach which we developed for a thermal neutron detector consisting of ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs. Three digital filters have been evaluated: a moving sum, a moving sum after differentiation and a digital CR-RC4 filter. The performances of the detector with these filters are presented. A full analog signal processing using a CR-RC4 filter has been emulated digitally. The detector performance obtained with this analog approach is compared with the one obtained with the best performing digital approach.

  7. Digital signal processing for a thermal neutron detector using ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs

    CERN Document Server

    Mosset, J -B; Greuter, U; Hildebrandt, M; Schlumpf, N

    2015-01-01

    We present a digital signal processing system based on a photon counting approach which we developed for a thermal neutron detector consisting of ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs. Three digital filters have been evaluated: a moving sum, a moving sum after differentiation and a digital CR-RC^4 filter. The performances of the detector with these filters are presented. A full analog signal processing using a CR-RC^4 filter has been emulated digitally. The detector performance obtained with this analog approach is compared with the one obtained with the best performing digital approach.

  8. Digital algorithms for parallel pipelined single-detector homodyne fringe counting in laser interferometry

    Science.gov (United States)

    Rerucha, Simon; Sarbort, Martin; Hola, Miroslava; Cizek, Martin; Hucl, Vaclav; Cip, Ondrej; Lazar, Josef

    2016-12-01

    The homodyne detection with only a single detector represents a promising approach in the interferometric application which enables a significant reduction of the optical system complexity while preserving the fundamental resolution and dynamic range of the single frequency laser interferometers. We present the design, implementation and analysis of algorithmic methods for computational processing of the single-detector interference signal based on parallel pipelined processing suitable for real time implementation on a programmable hardware platform (e.g. the FPGA - Field Programmable Gate Arrays or the SoC - System on Chip). The algorithmic methods incorporate (a) the single detector signal (sine) scaling, filtering, demodulations and mixing necessary for the second (cosine) quadrature signal reconstruction followed by a conic section projection in Cartesian plane as well as (a) the phase unwrapping together with the goniometric and linear transformations needed for the scale linearization and periodic error correction. The digital computing scheme was designed for bandwidths up to tens of megahertz which would allow to measure the displacements at the velocities around half metre per second. The algorithmic methods were tested in real-time operation with a PC-based reference implementation that employed the advantage pipelined processing by balancing the computational load among multiple processor cores. The results indicate that the algorithmic methods are suitable for a wide range of applications [3] and that they are bringing the fringe counting interferometry closer to the industrial applications due to their optical setup simplicity and robustness, computational stability, scalability and also a cost-effectiveness.

  9. Low level radioactivity measurements with phoswich detectors using coincident techniques and digital pulse processing analysis

    Energy Technology Data Exchange (ETDEWEB)

    Fuente, R. de la [University of Leon, Escuela de Ingenieria Industrial, Leon 24071 (Spain); Celis, B. de [University of Leon, Escuela de Ingenieria Industrial, Leon 24071 (Spain)], E-mail: bcelc@unileon.es; Canto, V. del; Lumbreras, J.M. [University of Leon, Escuela de Ingenieria Industrial, Leon 24071 (Spain); Celis, Alonso B. de [King' s College London, IoP, De Crespigny Park, SE58AF (United Kingdom); Martin-Martin, A. [Laboratorio LIBRA, Edificio I-D, Paseo Belen 3. 47011 Valladolid (Spain); Departamento de Fisica Teorica, Atomica y Optica, Facultad de Ciencias. Po Prado de la Magdalena, s/n. 47005 Valladolid (Spain)], E-mail: alonsomm@libra.uva.es; Gutierrez-Villanueva, J.L. [Laboratorio LIBRA, Edificio I-D, Paseo Belen 3. 47011 Valladolid (Spain); Departamento de Fisica Teorica, Atomica y Optica, Facultad de Ciencias. Po Prado de la Magdalena, s/n. 47005 Valladolid (Spain)], E-mail: joselg@libra.uva.es

    2008-10-15

    A new system has been developed for the detection of low radioactivity levels of fission products and actinides using coincidence techniques. The device combines a phoswich detector for {alpha}/{beta}/{gamma}-ray recognition with a fast digital card for electronic pulse analysis. The phoswich can be used in a coincident mode by identifying the composed signal produced by the simultaneous detection of {alpha}/{beta} particles and X-rays/{gamma} particles. The technique of coincidences with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty (NTBT) which established the necessity of monitoring low levels of gaseous fission products produced by underground nuclear explosions. With the device proposed here it is possible to identify the coincidence events and determine the energy and type of coincident particles. The sensitivity of the system has been improved by employing liquid scintillators and a high resolution low energy germanium detector. In this case it is possible to identify simultaneously by {alpha}/{gamma} coincidence transuranic nuclides present in environmental samples without necessity of performing radiochemical separation. The minimum detectable activity was estimated to be 0.01 Bq kg{sup -1} for 0.1 kg of soil and 1000 min counting.

  10. Application of QC_DR software for acceptance testing and routine quality control of direct digital radiography systems: initial experiences using the Italian Association of Physicist in Medicine quality control protocol.

    Science.gov (United States)

    Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa

    2009-12-01

    Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.

  11. Digital camera and smartphone as detectors in paper-based chemiluminometric genotyping of single nucleotide polymorphisms.

    Science.gov (United States)

    Spyrou, Elena M; Kalogianni, Despina P; Tragoulias, Sotirios S; Ioannou, Penelope C; Christopoulos, Theodore K

    2016-10-01

    Chemi(bio)luminometric assays have contributed greatly to various areas of nucleic acid analysis due to their simplicity and detectability. In this work, we present the development of chemiluminometric genotyping methods in which (a) detection is performed by using either a conventional digital camera (at ambient temperature) or a smartphone and (b) a lateral flow assay configuration is employed for even higher simplicity and suitability for point of care or field testing. The genotyping of the C677T single nucleotide polymorphism (SNP) of methylenetetrahydropholate reductase (MTHFR) gene is chosen as a model. The interrogated DNA sequence is amplified by polymerase chain reaction (PCR) followed by a primer extension reaction. The reaction products are captured through hybridization on the sensing areas (spots) of the strip. Streptavidin-horseradish peroxidase conjugate is used as a reporter along with a chemiluminogenic substrate. Detection of the emerging chemiluminescence from the sensing areas of the strip is achieved by digital camera or smartphone. For this purpose, we constructed a 3D-printed smartphone attachment that houses inexpensive lenses and converts the smartphone into a portable chemiluminescence imager. The device enables spatial discrimination of the two alleles of a SNP in a single shot by imaging of the strip, thus avoiding the need of dual labeling. The method was applied successfully to genotyping of real clinical samples. Graphical abstract Paper-based genotyping assays using digital camera and smartphone as detectors.

  12. Physical characteristics of GE Senographe Essential and DS digital mammography detectors.

    Science.gov (United States)

    Ghetti, Caterina; Borrini, Adriano; Ortenzia, Ornella; Rossi, Raffaella; Ordóñez, Pedro L

    2008-02-01

    The purpose of this study was to investigate physical characteristics of two full field digital mammography (FFDM) systems (GE Senographe Essential and DS). Both are indirect conversion (x ray to light) alpha-Si flat panels coupled with a CsI(Tl) scintillator. The examined systems have the same pixel size (100 microm) but a different field of view: a conventional size 23 x 19.2 cm2 and a large field 24 X 30.7 cm2, specifically designed to image large breasts. In the GE Senographe Essential model relevant improvements in flat panel design were implemented and new deposition tools for metal, alpha-Si, and CsI(Tl) were introduced by GE. These changes in detector design are expected to be beneficial for advanced applications such as breast tomosynthesis. The presampling modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE) were measured for a wide range of exposure (25-240 microGy) with a RQA-M2 technique (28 kVp with a Mo/Mo target/filter combination and 2 mm of additional aluminum filtration). At 1, 2, and at 4 lp/mm MTF is equal to 0.9, 0.76, and 0.46 for the conventional field detector and to 0.85, 0.59, and 0.24 for the large field detector. The latter detector exhibits an improved NNPS due to a lower electronic noise and a better DQE that reaches 60%. In addition a contrast-detail analysis was performed with CDMAM 3.4 phantom and CDCOM software: GE Senographe DS showed statistically significant poorer detection ability in comparison with the GE Senographe Essential. These results could have been expected, at least qualitatively, considering the relative DQE of the two systems.

  13. Aerogel for FARICH detector

    Energy Technology Data Exchange (ETDEWEB)

    Barnyakov, A.Yu. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Barnyakov, M.Yu. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State Technical University, Karl Marks 20, Novosibirsk 630073 (Russian Federation); Bobrovnikov, V.S.; Buzykaev, A.R.; Gulevich, V.V. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Danilyuk, A.F. [Boreskov Institute of Catalysis, Lavrentieva 5, Novosibirsk 630090 (Russian Federation); Kononov, S.A.; Kravchenko, E.A. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State University, Pirogova 2, Novosibirsk 630090 (Russian Federation); Kuyanov, I.A. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Lopatin, S.A. [Boreskov Institute of Catalysis, Lavrentieva 5, Novosibirsk 630090 (Russian Federation); Onuchin, A.P.; Ovtin, I.V.; Podgornov, N.A. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Novosibirsk State Technical University, Karl Marks 20, Novosibirsk 630073 (Russian Federation); Porosev, V.V. [Budker Institute of Nuclear Physics, Lavrentieva 11, Novosibirsk 630090 (Russian Federation); Predein, A.Yu.; Protsenko, R.S. [Boreskov Institute of Catalysis, Lavrentieva 5, Novosibirsk 630090 (Russian Federation)

    2014-12-01

    We present our current experience in preparation of focusing aerogels for the Focusing Aerogel RICH detector. Multilayer focusing aerogel tiles have been produced in Novosibirsk by a collaboration of the Budker Institute of Nuclear Physics and Boreskov Institute of Catalysis since 2004. We have obtained 2–3–4-layer blocks with the thickness of 30–45 mm. In 2012, the first samples of focusing blocks with continuous density (refractive index) gradient along thickness were produced. This technology can significantly reduce the contribution from the geometric factor of the radiator thickness to the resolution of the measured Cherenkov angle in the FARICH detector. The special installation was used for automatic control of reagents ratio during the synthesis process. The first samples were tested using the digital radiography method and on the electron beam with the FARICH prototype.

  14. Industrial radiographies

    CERN Multimedia

    2005-01-01

    The Radiation Protection group wishes to remind CERN staff responsible for contractors performing X-ray inspections on the CERN sites that the firms must apply the legislation in force in their country of origin, in particular with regard to the prevention of risks relating to ionizing radiation. Industrial radiography firms called on to work on the CERN sites must also comply with the rules laid down in CERN's Radiation Safety Manual and be registered in the relevant CERN database. Since CERN is responsible for safety on its own site, a number of additional rules have been laid down for this kind of work, as set out in Radiation Protection Procedure PRP30 https://edms.cern.ch/file/346848/LAST_RELEASED/PRP30.pdf The CERN Staff Member responsible for the contract shall register the company and issue notification that an X-ray inspection is to be performed via the web interface at the following address: http://cern.ch/rp-radio

  15. Detector evaluation of a prototype amorphous selenium-based full field digital mammography system

    Science.gov (United States)

    Jesneck, Jonathan L.; Saunders, Robert S.; Samei, Ehsan; Xia, Jessie Q.; Lo, Joseph Y.

    2005-04-01

    This study evaluated the physical performance of a selenium-based direct full-field digital mammography prototype detector (Siemens Mammomat NovationDR), including the pixel value vs. exposure linearity, the modulation transfer function (MTF), the normalized noise power spectrum (NNPS), and the detective quantum efficiency (DQE). The current detector is the same model which received an approvable letter from FDA for release to the US market. The results of the current prototype are compared to those of an earlier prototype. Two IEC standard beam qualities (RQA-M2: Mo/Mo, 28 kVp, 2 mm Al; RQA-M4: Mo/Mo, 35 kVp, 2 mm Al) and two additional beam qualities (MW2: W/Rh, 28 kVp, 2 mm Al; MW4: W/Rh, 35 kVp, 2 mm Al) were investigated. To calculate the modulation transfer function (MTF), a 0.1 mm Pt-Ir edge was imaged at each beam quality. Detector pixel values responded linearly against exposure values (R2 0.999). As before, above 6 cycles/mm Mo/Mo MTF was slightly higher along the chest-nipple axis compared to the left-right axis. MTF was comparable to the previously reported prototype, with slightly reduced resolution. The DQE peaks ranged from 0.71 for 3.31 μC/kg (12.83 mR) to 0.4 for 0.48 μC/kg (1.86 mR) at 1.75 cycles/mm for Mo/Mo at 28 kVp. The DQE range for W/Rh at 28 kVP was 0.81 at 2.03 μC/kg (7.87 mR) to 0.50 at 0.50 μC/kg (1.94 mR) at 1 cycle/mm. NNPS tended to increase with greater exposures, while all exposures had a significant low-frequency component. Bloom and detector edge artifacts observed previously were no longer present in this prototype. The new detector shows marked noise improvement, with slightly reduced resolution. There remain artifacts due to imperfect gain calibration, but at a reduced magnitude compared to a prototype detector.

  16. 直接数字化X线摄影在鼻骨摄影中的应用%Application of direct digital radiography of nasal bone

    Institute of Scientific and Technical Information of China (English)

    高登发; 王海军; 张爱莲; 王玉林

    2005-01-01

    目的探讨直接数字化X线摄影(direct digitized radiography, DDR)在鼻骨摄影中的应用价值.方法对100例DDR鼻骨侧位影像采用图像后处理方法中多级图像对比增益法,又称"交响乐"功能(multi-scale image contrast amplification, MUSICA)、影像切割与局部放大等功能进行后处理,同时数字随机法对其中30例行普通X线摄影.由放射科经验丰富的医、技师各2名对所有鼻骨影像进行分析,评价其对鼻骨骨折、鼻骨整体及鼻周软组织的显示.结果 100例DDR鼻骨影像中,诊断骨折46例,鼻骨整体及鼻周软组织显示满意的分别为95和92例;对照组30例DDR鼻骨影像发现骨折18例,X线片发现骨折11例,漏诊7例(χ2=5.14,P<0.05),30例DDR影像中,鼻骨整体及鼻周软组织显示满意的均为28例;普通X线片两者显示满意的分别为6例(χ2=20.05,P<0.05)和10例(χ2=15.06,P<0.05).结论 DDR影像比普通X线影像能更好的显示鼻骨和鼻周软组织,提高鼻骨骨折的检出率.

  17. Comparative study of positron emission tomography and quantitative digital radiography (QDR) in detecting effects of aging and diet on bone metabolism of guinea pig

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, K.; Inoue, Tomio; Tomiyoshi, Katsumi; Sarwar, M.; Oriuchi, Noboru; Mizunuma, Hideki; Endo, Keigo [Gunma Univ., Maebashi (Japan). School of Medicine

    1998-07-01

    The purpose of this study was to compare positron emission tomography and quantitative digital radiography (QDR) in detecting the effects of aging and diet on bone metabolism. Bone imaging of guinea pigs was performed with fluorine-18 fluoride ions using a high-resolution animal PET system to analyze bone metabolism quantitatively in different age groups of guinea pigs, young (8 weeks), adult (36 weeks), and aged groups (96 weeks), and also in a dietary manipulation group (low calcium and low vitamin D{sub 3} diet for 1, 2, and 3 weeks). A three-compartment kinetic model was applied for the analysis of bone metabolism to evaluate the rate constant (K, K1-K4). There was a significant difference in K-constant between the young and other groups. The K-constant was higher (0.100{+-}0.005 ml/min/ml) in the young group than in adults (0.028{+-}0.001 ml/min/ml) (p<0.001) and the aged group (0.047{+-}0.020 ml/min/ml). This high value of the K-constant in the young group indicates high turnover in bone metabolism, but there was no significant difference between the adult and aged groups. Bone mineral density (BMD) was lower in the young group (0.15{+-}0.026 g/cm{sup 2}) than in the adult (0.230{+-}0.021 g/cm{sup 2}) (p<0.001) and aged groups (0.26{+-}0.03 g/cm{sup 2}). There was no significant difference in BMD between the adult and aged groups. Although there was no difference in BMD between the control and dietary manipulation groups, PET study revealed a significant difference in K-constant between them (0.028{+-}0.001 vs. 0.090{+-}0.009 ml/min/ml) (p<0.001). The quantitative skeletal dynamic PET study with {sup 18}F fluoride ions was more sensitive and superior in the early detection of metabolic disorders in bone disease than QDR. (author)

  18. Development of gas microstrip detectors for digital x-ray imaging and radiation dosimetry

    CERN Document Server

    Dixit, M S; Dubeau, J; Gobbi, D G; Johns, P C; Karlen, Dean A; Oakham, F G; Waker, A J

    1998-01-01

    Our recent work in the application of gas microstrip detector (GMD) technology to the fields of digital X-ray imaging and radiation dosimetry Is described. The GMD can measure the position and the energy of individual photons at the high counting rates encountered in X-ray imaging. GMD-based imaging systems have high detective quantum efficiency and permit improvement of image quality and contrast using display windowing and measured energy information. Results are presented on the performance of a prototype GMD imaging system operated with a xenon/methane 90/10 gas mixture at 1 atm. Results are also presented on the performance of a GMD filled with tissue equivalent gases for applications in the field of radiation dosimetry in mixed neutron and gamma fields. The results show that the GMD can be used for dosimetric discrimination between different types of radiation in mixed-field environments.

  19. A Medipix2-based imaging system for digital mammography with silicon pixel detectors

    CERN Document Server

    Bisogni, M G; Fantacci, M E; Mettivier, G; Montesi, M C; Novelli, M; Quattrocchi, M; Rosso, V; Russo, P; Stefanini, A

    2004-01-01

    In this paper we present the first tests of a digital imaging system based on a silicon pixel detector bump-bonded to an integrated circuit operating in single photon counting mode. The X-rays sensor is a 300 mu m thick silicon, 14 by 14 mm/sup 2/, upon which a matrix of 256 * 256 pixels has been built. The read-out chip, named MEDIPIX2, has been developed at CERN within the MEDIPIX2 Collaboration and it is composed by a matrix of 256 * 256 cells, 55 * 55 mu m/sup 2/. The spatial resolution properties of the system have been assessed by measuring the square wave resolution function (SWRF) and first images of a standard mammographic phantom were acquired using a radiographic tube in the clinical irradiation condition. (5 refs).

  20. Optimized light sharing for high-resolution TOF PET detector based on digital silicon photomultipliers.

    Science.gov (United States)

    Marcinkowski, R; España, S; Van Holen, R; Vandenberghe, S

    2014-12-07

    The majority of current whole-body PET scanners are based on pixelated scintillator arrays with a transverse pixel size of 4 mm. However, recent studies have shown that decreasing the pixel size to 2 mm can significantly improve image spatial resolution. In this study, the performance of Digital Photon Counter (DPC) from Philips Digital Photon Counting (PDPC) was evaluated to determine their potential for high-resolution whole-body time of flight (TOF) PET scanners. Two detector configurations were evaluated. First, the DPC3200-44-22 DPC array was coupled to a LYSO block of 15 × 15 2 × 2 × 22 mm(3) pixels through a 1 mm thick light guide. Due to light sharing among the dies neighbour logic of the DPC was used. In a second setup the same DPC was coupled directly to a scalable 4 × 4 LYSO matrix of 1.9 × 1.9 × 22 mm(3) crystals with a dedicated reflector arrangement allowing for controlled light sharing patterns inside the matrix. With the first approach an average energy resolution of 14.5% and an average CRT of 376 ps were achieved. For the second configuration an average energy resolution of 11% and an average CRT of 295 ps were achieved. Our studies show that the DPC is a suitable photosensor for a high-resolution TOF-PET detector. The dedicated reflector arrangement allows one to achieve better performances than the light guide approach. The count loss, caused by dark counts, is overcome by fitting the matrix size to the size of DPC single die.

  1. Evaluation of a compact, high-resolution SPECT detector based on digital silicon photomultipliers.

    Science.gov (United States)

    Bouckaert, Carmen; Vandenberghe, Stefaan; Van Holen, Roel

    2014-12-07

    MicroSPECT is one of the main functional imaging techniques used in the preclinical setting. Even though high-resolution images can be obtained with currently available systems, their sensitivity is often quite low due to the use of multi-pinhole collimation. This results in long acquisition times and hampers dynamic imaging. However, it has already been shown that this limited sensitivity can be overcome using high-resolution detectors. In this article, we therefore investigated the use of a digital photon counter (DPC) in combination with a 2 mm thick monolithic LYSO crystal for SPECT imaging. These light sensors contain arrays of avalanche photodiodes whose signals are directly digitised. The DPCs have the advantage that they are very compact, have a high intrinsic resolution, are MR compatible and allow disabling cells with a high dark count rate. In order to investigate the influence of the temperature dependent dark count rate on the detector performance, we compared it at 3 °C and 18 °C. At 3 °C, we observed an energy resolution of 28.8% and an intrinsic spatial resolution of 0.48 mm. Furthermore, the count rate at 10% loss is 60 kcps. Next, we looked at the event loss at 18 °C caused by the higher dark count rate and found a 5% loss compared to the 3 °C measurements. At this higher temperature the energy resolution becomes 29.2% and the intrinsic spatial resolution decreases to 0.52 mm. Due to the 5% count loss, the count rate at 10% loss increases to 63 kcps. A small degradation of the detector performance is thus observed at 18 °C.These results show the usefulness of this detector for SPECT imaging together with its excellent intrinsic spatial resolution. A drawback of the detector is its low, spatially varying energy resolution. Even though the detection efficiency and intrinsic spatial resolution are better at 3 °C, results are still acceptable at 18 °C.

  2. Online digital filter and QRS detector applicable in low resource ECG monitoring systems.

    Science.gov (United States)

    Tabakov, Serafim; Iliev, Ivo; Krasteva, Vessela

    2008-11-01

    The present work describes fast computation methods for real-time digital filtration and QRS detection, both applicable in autonomous personal ECG systems for long-term monitoring. Since such devices work under considerable artifacts of intensive body and electrode movements, the input filtering should provide high-quality ECG signals supporting the accurate ECG interpretation. In this respect, we propose a combined high-pass and power-line interference rejection filter, introducing the simple principle of averaging of samples with a predefined distance between them. In our implementation (sampling frequency of 250 Hz), we applied averaging over 17 samples distanced by 10 samples (Filter10x17), thus realizing a comb filter with a zero at 50 Hz and high-pass cut-off at 1.1 Hz. Filter10x17 affords very fast filtering procedure at the price of minimal computing resources. Another benefit concerns the small ECG distortions introduced by the filter, providing its powerful application in the preprocessing module of diagnostic systems analyzing the ECG morphology. Filter10x17 does not attenuate the QRS amplitude, or introduce significant ST-segment elevation/depression. The filter output produces a constant error, leading to uniform shifting of the entire P-QRS-T segment toward about 5% of the R-peak amplitude. Tests with standardized ECG signals proved that Filter10x17 is capable to remove very strong baseline wanderings, and to fully suppress 50 Hz interferences. By changing the number of the averaged samples and the distance between them, a filter design with different cut-off and zero frequency could be easily achieved. The real-time QRS detector is designed with simplified computations over single channel, low-resolution ECGs. It relies on simple evaluations of amplitudes and slopes, including history of their mean values estimated over the preceding beats, smart adjustable thresholds, as well as linear logical rules for identification of the R-peaks in real

  3. The research of optimizing exposure factors in digital chest radiography%数字X线胸部摄影适宜检查参数的研究

    Institute of Scientific and Technical Information of China (English)

    孙建忠; 王志康; 章伟敏; 蔡劲松

    2010-01-01

    目的 探讨DR胸部摄影的适宜检查参数.方法 选择73、90、125 kV分别代表低、亚高、高kV,分别选择感度200、400、800以及各级感度±4微调,使用自动曝光控制(AEC)模式对内嵌有CDRAD 2.0的胸部体模曝光,记录每次曝光的剂量面积值(DAP).应用CDRAD 2.0配套分析软件Artinis CDRAD Analyzer 1.1自动分析每次曝光的图像质量(IQFinv)值.选择10名志愿者进行73 kV,S800-2;90 kV,S800+2;125 kV,S400+2,3种组合曝光,由2名医师进行评分,记录其DAP值,所得数据应用SPSS12.0软件进行单因素方差分析.结果 (1)3种组合志愿者曝光图像质量评分73、90、125 kV分别为(2.7±0.5)、(2.9±0.3)、(2.8±0.4)分,差异无统计学意义(F=0.587,P>0.05).73、90、125 kV的DAP分别为(29.1±7.9)、(30.5±4.5)、(40.4±7.6)mGy·cm2,差异有统计学意义(F=9.803,P<0.01).(2)3种kV体模曝光DAP值随着感度的增高而下降.每级感度间,DAP值相差11%;相同感度等级,DAP值73 kV>90 kV>125 kV.(3)3种kV体模曝光IQFinv 值均随着感度的增高而下降,相同曝光剂量下,IQFinv值73 kV>90 kV>125 kV.结论 90 kV与感度S800+2~S800+4组合是DR胸部X线摄影较为适宜的检查参数.%Objective To explore the optimum exposure factors in digital chest radiography.Methods Chest phantom was exposed under auto exposure control model with 73, 90, 125kV and S200,400,800 plus or minor 4 micro-adjust for each sensitivity grade. Meanwhile dose area product (DAP) was recorded and the value of IQFinv was analyzed automatically by Artinis CDRAD Analyzer 1.1. Ten volunteers were exposed with 73 kV, S800 - 2; 90 kV, S800 + 2 and 125 kV, S400 + 2. Two radiologists evaluated and scored image quality. Statistical analysis was performed using one way ANOVA test by SPSS 12. 0. Results ( 1 ) The quality scores of volunteers' images obtained with three combinations of exposure factors were 2. 7 ± 0. 5 for 73 kV group, 2. 9 ± 0. 3 for 90 kV group and 2. 8 ± 0. 4 for

  4. A time digitizer for the microstrip detectors of the PANDA MVD

    Energy Technology Data Exchange (ETDEWEB)

    Riccardi, Alberto; Brinkmann, Kai-Thomas; Di Pietro, Valentino [II. Physikalisches Institut, Justus-Liebig-Universitaet Giessen (Germany); Garbolino, Sara; Rivetti, Angelo; Rolo, Manuel [INFN Sezione di Torino, Torino (Italy); Collaboration: PANDA-Collaboration

    2015-07-01

    In nuclear detectors the information on the energy of the particle is usually obtained by measuring the amplitude of the signal delivered by the sensor. The low voltage power supply used in modern deep submicron technologies constrain the maximum dynamic range of the ADC. Still, the energy information can be obtained with time-based techniques, in which the energy is associated with the duration of the signal through the Time over Threshold method. This work is focused on the PANDA Micro Vertex Detector and explores the possibility of applying a time-based readout approach for the microstrip sensors. In PANDA, the strip system must cope with hit rates up to 50 kHz per channel. Therefore, the front-end output must be relatively short, this implies that the clock resolution is not enough to measure the signal duration, so it is necessary to use a Time to Digital Converter. The front-end and the TDC structure are designed in a 0.11μm CMOS process. The TDC chosen is based on an analog clock interpolator because it combines good time resolution with a fairly simple implementation and low power consumption. In the presentation an overview of the analog part of the PASTA (PANDA strip ASIC) is presented.

  5. Resolution requirements for monitor viewing of digital flat-panel detector radiographs: a contrast detail analysis

    Science.gov (United States)

    Peer, Siegfried; Steingruber, Iris; Gassner, Eva; Peer, Regina; Giacomuzzi, Salvatore M.

    2002-05-01

    Since the introduction of digital flat panel detectors into clinical routine the discussion on monitor specifications for primary soft copy reading has gained new impetus. Major concerns exist for viewing of tiny opacities such as pulmonary nodules. In this study CDRAD phantom images were acquired on a caesium iodid/amorphous silicon detector at varying exposure levels. Images were read three times by three observers on a clinical 1K and 2K monitor workstation. All typical workstation functions such as magnification and window/level setting were applied during image reading. Correct detection ratios were calculated according to the CDRAD evaluation manual. Observer ratings were highest for high dose exposure and 2K monitor reading. No significant difference was detected in the correct detection ratio of observers. However, the difference between the two types of workstations (1K versus 2K monitors) despite less than 3% was significant at a 95% confidence level. This is in good accordance with recently published clinical studies. However, further clinical work will be needed to strengthen this laboratory based impression. Given these subtle differences in low contrast detail detection on 1K and 2K clinical PACS workstation we should probably rethink the recommendations of various national boards for the use of 2K monitors.

  6. Parameter investigation and first results from a digital flat panel detector with forward bias capability

    Science.gov (United States)

    Starman, Jared; Tognina, Carlo; Virshup, Gary; Star-lack, Josh; Mollov, Ivan; Fahrig, Rebecca

    2008-03-01

    Digital flat panel a-Si x-ray detectors can exhibit image lag of several percent. The image lag can limit the temporal resolution of the detector, and introduce artifacts into CT reconstructions. It is believed that the majority of image lag is due to defect states, or traps, in the a-Si layer. Software methods to characterize and correct for the image lag exist, but they may make assumptions such as the system behaves in a linear time-invariant manner. The proposed method of reducing lag is a hardware solution that makes few additional hardware changes. For pulsed irradiation, the proposed method inserts a new stage in between the readout of the detector and the data collection stages. During this stage the photodiode is operated in a forward bias mode, which fills the defect states with charge. Parameters of importance are current per diode and current duration, which were investigated under light illumination by the following design parameters: 1.) forward bias voltage across the photodiode and TFT switch, 2.) number of rows simultaneously forward biased, and 3.) duration of the forward bias current. From measurements, it appears that good design criteria for the particular imager used are 8 or fewer active rows, 2.9V (or greater) forward bias voltage, and a row frequency of 100 kHz or less. Overall, the forward bias method has been found to reduce first frame lag by as much as 95%. The panel was also tested under x-ray irradiation. Image lag improved (94% reduction), but the temporal response of the scintillator became evident in the turn-on step response.

  7. An advanced image processing method to improve the spatial resolution of ion radiographies

    Science.gov (United States)

    Krah, N.; Testa, M.; Brons, S.; Jäkel, O.; Parodi, K.; Voss, B.; Rinaldi, I.

    2015-11-01

    We present an optimization method to improve the spatial resolution and the water equivalent thickness (WET) accuracy of ion radiographies. The method is designed for imaging systems measuring for each actively scanned beam spot the lateral position of the pencil beam and at the same time the Bragg curve (behind the target) in discrete steps without relying on tracker detectors to determine the ion trajectory before and after the irradiated volume. Specifically, the method was used for an imaging set-up consisting of a stack of 61 parallel-plate ionization chambers (PPIC) interleaved with absorber plates of polymethyl methacrylate (PMMA) working as a range telescope. The method uses not only the Bragg peak position, but approximates the entire measured Bragg curve as a superposition of differently shifted Bragg curves. Their relative weights allow to reconstruct the distribution of thickness around each scan spot of a heterogeneous phantom. The approach also allows merging the ion radiography with the geometric information of a co-registered x-ray radiography in order to increase its spatial resolution. The method was tested using Monte Carlo simulated and experimental proton radiographies of a PMMA step phantom and an anthropomorphic head phantom. For the step phantom, the effective spatial resolution was found to be 6 and 4 times higher than the nominal resolution for the simulated and experimental radiographies, respectively. For the head phantom, a gamma index was calculated to quantify the conformity of the simulated proton radiographies with a digitally reconstructed radiography (DRR) obtained from an x-ray CT and properly converted into WET. For a distance-to-agreement (DTA) of 2.5 mm and a relative WET difference (RWET) of 2.5%, the passing ratio was 100%/85% for the optimized/non-optimized case, respectively. When the optimized proton radiography was merged with the co-registered DRR, the passing ratio was 100% at DTA  =  1.3 mm and RWET

  8. FemtoDAQ: A Low-Cost Digitizer for SiPM-Based Detector Studies and its Application to the HAWC Detector Upgrade

    CERN Document Server

    Skulski, Wojtek; BenZvi, Segev

    2016-01-01

    The FemtoDAQ is a low-cost two channel data acquisition system which we have used to investigate the signal characteristics of silicon photomultipliers (SiPMs) coupled to fast scintillators. The FemtoDAQ system can also be used to instrument low cost moderate performance passive detectors, and is suitable for use in harsh environments (e.g., high altitude). The FemtoDAQ is being used as a SiPM test bench for the High Altitude Water Cherenkov (HAWC) Observatory, a TeV gamma ray detector located 4100 m above sea level. Planned upgrades to the HAWC array can benefit greatly from SiPMs, a robust, low-voltage, low-cost alternative to traditional vacuum photomultipliers. The FemtoDAQ is used to power the SiPM detector front end, bias the SiPM, and digitize the photosensor output in a single compact unit.

  9. FemtoDAQ: A Low-Cost Digitizer for SiPM-Based Detector Studies and Its Application to the HAWC Detector Upgrade

    Science.gov (United States)

    Skulski, Wojtek; Ruben, Andreas; BenZvi, Segev

    2017-07-01

    The FemtoDAQ is a low-cost two-channel data acquisition system that we have used to investigate the signal characteristics of silicon photomultipliers (SiPMs) coupled to fast scintillators. The FemtoDAQ system can also be used to instrument low-cost moderate-performance passive detectors, and is suitable for use in harsh environments (e.g., high altitude). The FemtoDAQ is being used as a SiPM test bench for the High Altitude Water Cherenkov (HAWC) Observatory, a TeV gamma ray detector located 4100 m above sea level. Planned upgrades to the HAWC array can benefit greatly from SiPMs, a robust low-voltage low-cost alternative to traditional vacuum photomultipliers. The FemtoDAQ is used to power the SiPM detector front end, bias the SiPM, and digitize the photosensor output in a single compact unit.

  10. A highly accurate wireless digital sun sensor based on profile detecting and detector multiplexing technologies

    Science.gov (United States)

    Wei, Minsong; Xing, Fei; You, Zheng

    2017-01-01

    The advancing growth of micro- and nano-satellites requires miniaturized sun sensors which could be conveniently applied in the attitude determination subsystem. In this work, a profile detecting technology based high accurate wireless digital sun sensor was proposed, which could transform a two-dimensional image into two-linear profile output so that it can realize a high update rate under a very low power consumption. A multiple spots recovery approach with an asymmetric mask pattern design principle was introduced to fit the multiplexing image detector method for accuracy improvement of the sun sensor within a large Field of View (FOV). A FOV determination principle based on the concept of FOV region was also proposed to facilitate both sub-FOV analysis and the whole FOV determination. A RF MCU, together with solar cells, was utilized to achieve the wireless and self-powered functionality. The prototype of the sun sensor is approximately 10 times lower in size and weight compared with the conventional digital sun sensor (DSS). Test results indicated that the accuracy of the prototype was 0.01° within a cone FOV of 100°. Such an autonomous DSS could be equipped flexibly on a micro- or nano-satellite, especially for highly accurate remote sensing applications.

  11. International Neutron Radiography Newsletter

    DEFF Research Database (Denmark)

    Domanus, Joseph Czeslaw

    1986-01-01

    At the First World Conference on Neutron Radiography i t was decided to continue the "Neutron Radiography Newsletter", published previously by J.P. Barton, as the "International Neutron Radiography Newsletter" (INRNL), with J.C. Doraanus as editor. The British Journal of Non-Destructive Testing...

  12. [Flat-panel detectors in X-ray systems].

    Science.gov (United States)

    Spahn, M; Heer, V; Freytag, R

    2003-05-01

    For all application segments X-ray systems with flat-panel detectors increasingly enter the market. In digital radiography,mammography and cardiologic angiography flat-panel detectors are already well established while they are made ready for market introduction in general angiography and fluoroscopy. Two flat-panel detector technologies are available. One technology is based on an indirect conversion process of X-rays while the other one uses a direct conversion method. For radiography and dynamic applications the indirect method provides substantial advantages, while the direct method has some benefits for mammography. In radiography and mammography flat-panel detectors lead to clear improvements with respect to workflow, image quality and dose reduction potentials. These improvements are fostered by the immediate availability of the image, the large dynamic range and the high sensitivity to X-rays. New applications and the use of complex image processing algorithms have the potential to enlarge the present diagnostic range of applications. Up to now, image intensifiers are still the well-established technology for angiography and fluoroscopy. Nevertheless flat-panel detectors begin to enter this field, especially in cardiologic angiography. Characteristics of flat-panel detectors such as the availability of distortion-free images, the excellent contrast resolution, the large dynamic range, the high sensitivity to X-rays and the usability in magnetic fields provide the basis for improved and new diagnostic and interventional methods.

  13. Progress in electron-multiplying CCD (EMCCD) based high-resolution high-sensitivity x-ray detector for fluoroscopy and radiography

    Science.gov (United States)

    Kuhls, Andrew T.; Yadava, Girijesh; Patel, Vikas; Bednarek, Daniel R.; Rudin, Stephen

    2007-03-01

    A new high-resolution, high-sensitivity, low-noise x-ray detector based on EMCCDs has been developed. The EMCCD detector module consists of a 1kx1k, 8μm pixel EMCCD camera coupled to a CsI(Tl) scintillating phosphor via a fiber optic taper (FOT). Multiple modules can be used to provide the desired field-of-view (FOV). The detector is capable of acquisitions over 30fps. The EMCCD's variable gain of up to 2000x for the pixel signal enables high sensitivity for fluoroscopic applications. With a 3:1 FOT, the detector can operate with a 144μm effective pixel size, comparable to current flat-panel detectors. Higher resolutions of 96 and 48μm pixel size can also be achieved with various binning modes. The detector MTFs and DQEs were calculated using a linear-systems analysis. The zero frequency DQE was calculated to be 59% at 74 kVp. The DQE for the 144μm pixel size was shown to exhibit quantum-noise limited behavior down to ~0.1μR using a conservative 30x gain. At this low exposure, gains above 30x showed limited improvements in DQE suggesting such increased gains may not be necessary. For operation down to 48µm pixel sizes, the detector instrumentation noise equivalent exposure (INEE), defined as the exposure where the instrumentation noise equals the quantum-noise, was flat-panel detectors for applications such as fluoroscopy and angiography requiring high frame rates, resolution, dynamic range and sensitivity while maintaining essentially no lag and very low INEE. Initial images from a prototype detector are also presented.

  14. Parallel readout of two-element CdZnTe detectors with real-time digital signal processing

    Energy Technology Data Exchange (ETDEWEB)

    Shi Zhubin; Wang Linjun; Qin Kaifeng; Min Jiahua; Zhang Jijun; Liang Xiaoyan; Huang Jian; Tang Ke; Xia Yiben, E-mail: ljwang@shu.edu.cn [School of Materials Science and Engineering, Shanghai University, Shanghai 200072 (China)

    2010-12-15

    Readout electronics, especially digital electronics, for two-element CdZnTe (CZT) detectors in parallel are developed. The preliminary results show the detection efficiency of the two-element CZT detectors in parallel with analog electronics is as many as 1.8 and 2.1 times the single ones, and the energy resolution (FWHM) is limited by that of the single one by the means of analog electronics. However, the digital method for signal processing will be sufficiently better by contrast with an analog method especially in energy resolution. The energy resolution by the means of digital electronics can be improved by about 26.67%, compared to that only with analog electronics, while their detection efficiency is almost the same. The cause for this difference is also discussed. (semiconductor devices)

  15. SEMICONDUCTOR DEVICES Parallel readout of two-element CdZnTe detectors with real-time digital signal processing

    Science.gov (United States)

    Zhubin, Shi; Linjun, Wang; Kaifeng, Qin; Jiahua, Min; Jijun, Zhang; Xiaoyan, Liang; Jian, Huang; Ke, Tang; Yiben, Xia

    2010-12-01

    Readout electronics, especially digital electronics, for two-element CdZnTe (CZT) detectors in parallel are developed. The preliminary results show the detection efficiency of the two-element CZT detectors in parallel with analog electronics is as many as 1.8 and 2.1 times the single ones, and the energy resolution (FWHM) is limited by that of the single one by the means of analog electronics. However, the digital method for signal processing will be sufficiently better by contrast with an analog method especially in energy resolution. The energy resolution by the means of digital electronics can be improved by about 26.67%, compared to that only with analog electronics, while their detection efficiency is almost the same. The cause for this difference is also discussed.

  16. Measuring Io's Lava Eruption Temperatures with a Novel Infrared Detector and Digital Readout Circuit

    Science.gov (United States)

    Davies, Ashley; Gunapala, Sarath; Rafol, B., Sir; Soibel, Alexander; Ting, David Z.

    2016-10-01

    One method of determining lava eruption temperature of Io's dominant silicate lavas is by measuring radiant flux at two or more wavelengths and fitting a black-body thermal emission function. Only certain styles of volcanic activity are suitable, those where thermal emission is from a restricted range of surface temperatures close to eruption temperature. Such processes include [1] large lava fountains; [2] fountaining in lava lakes; and [3] lava tube skylights. Problems that must be overcome are (1) the cooling of the lava between data acquisitions at different wavelengths; (2) the unknown magnitude of thermal emission, which often led to detector saturation; and (3) thermal emission changing on a shorter timescale than the observation integration time. We can overcome these problems by using the HOT-BIRD detector [4] and an advanced digital readout circuit [5]. We have created an instrument model that allows different instrument parameters (including mirror diameter, number of signal splits, exposure duration, filter band pass, and optics transmissivity) to be tested so as to determine eruption detectability. We find that a short-wavelength infrared instrument on an Io flyby mission can achieve simultaneity of observations by splitting the incoming signal for all relevant eruption processes and obtain data fast enough to remove uncertainties in accurate determination of the highest lava surface temperatures exposed. Observations at 1 and 1.5 μm are sufficient to do this. Lava temperature determinations are also possible with a visible wavelength detector [3] so long as data at different wavelengths are obtained simultaneously and integration time is very short. This is especially important for examining the thermal emission from lava tube skylights [3] due to rapidly-changing viewing geometry during close flybys. References: [1] Davies et al., 2001, JGR, 106, 33079-33104. [2] Davies et al., 2011, GRL, 38, L21308. [3] Davies et al., 2016, Icarus, in press. [4

  17. 成人胸部适当高电压数字X线摄影试验研究%Optimisation of tube voltage for adult chest digital radiography

    Institute of Scientific and Technical Information of China (English)

    赵永霞; 秦维昌; 黄玲; 张晓晶; 亓恒涛; 刘传亚; 王巍

    2010-01-01

    Objective To explore the optimum voltage for digital chest radiography in adult. Methods PMMAs of Different thickness (7.2, 9.0, 10. 8 and 12. 6 cm) were used to simulate chest of different depth ( 17. 5, 22. 5, 27.0 and 32. 5 cm). The combinants of contrast-detail Cdrad 2.0 phantom and above PMMAs were exposed with automatic exposure control (AEC) and different tube voltages. The images of these combinants were obtained and the entrance surface dose (ESD) was recorded. The imaging quality factor (IQF) was calculated and the curves were drawn between the ESD,IQF and kV. The PMMAs of different thickness, on which a contrast object ( PMAA of 5 cm diameter and 1.8 cm thickness ) was placed, were exposed with the same condition used for above test. Their images were obtained and SNRs were calculated. Results The ESD, SNR and IQFinv of different chest depth decreased with increase of kV.When tube voltages of 70, 100 and 140 kV were used, for 17. 5 cm chest depth, the ESD was 0. 22, 0. 09 and 0. 06 mGy, the IQF was 43.3, 58. 8 and 72. 0, the SNR was 7.5, 6. 2 and 5.0; for 22. 5 cm chest depth, the ESD was 0.37, 0.12 and 0.06 mGy, the IQF was 56. 0, 61.4 and 65.3, the SNR was 6. 4, 5.2 and 3. 8; for 27. 0 cm chest depth, the ESD was 0. 52, 0. 20 and 0. 09 mGy, the IQF was 54. 2, 64. 3 and 91. 0, the SNR was 6. 0, 4. 8 and 3. 5; for 31.5 cm chest depth, the ESD was 0.53, 0.24 and 0. 10 mGy,the IQF was 53.2, 66. 8 and 95.3, the SNR was 5. 7, 4. 5 and 3. 0. Conclusion To balance ESD, SNR and IQF, proper tube voltage should be chosen for chest radiography according to thickness and constitution of patients.%目的 探讨成人胸部不同厚度高千伏DR的适当电压千伏值.方法 用不同厚度的聚甲基丙烯酸甲酯(PMMA)模拟不同成人胸部厚度,用不同电压、自动曝光控制(AEC)摄影,记录入射体表剂量(ESD)、获取模体影像并计算影像质量因子(IQF),绘制ESD和IQF之间的曲线.将一块厚度为1.8 cm(5 cm×5 cm)的PMMA作为对

  18. The value of digital tomosynthesis of the chest as a problem-solving tool for suspected pulmonary nodules and hilar lesions detected on chest radiography

    Energy Technology Data Exchange (ETDEWEB)

    Galea, Angela, E-mail: galeaangie@gmail.com [Peninsula Radiology Academy, William Prance Road, Plymouth PL65WR (United Kingdom); Dubbins, Paul, E-mail: Paul.dubbins@nhs.net [Plymouth Hospital NHS Trust, Plymouth PL68DH (United Kingdom); Riordan, Richard, E-mail: richardriordan@nhs.net [Plymouth Hospital NHS Trust, Plymouth PL68DH (United Kingdom); Adlan, Tarig, E-mail: tarig.adlan@nhs.net [Plymouth Hospital NHS Trust, Plymouth PL68DH (United Kingdom); Roobottom, Carl, E-mail: carl.roobotoom@nhs.net [Plymouth Hospital NHS Trust, Plymouth PL68DH (United Kingdom); Gay, David, E-mail: davegay@nhs.net [Plymouth Hospital NHS Trust, Plymouth PL68DH (United Kingdom)

    2015-05-15

    Graphical abstract: When compared to CXR, DTS has: • Superior resolution • Better assessment of location in the AP dimension (better at locating a pleural or intrapulmonary lesion) • Better characterisation (better at distinguishing between calcified plaque and soft tissue) • Removes composite artefact caused by overlying anatomical structures (such as the ribs or pulmonary vessels) DTS has improved sensitivity, specificity and accuracy when compared to CXR. - Highlights: • DTS is a type of limited angle tomography. Sixty coronal reconstructed images of the chest are produced that combine the superior resolution of radiography with the tomographic benefits of computed tomography. • The sensitivity for detecting a suspected lung lesions is 0.65 with CXR and 0.91 for DTS. • The high specificity of DTS (1) and the high negative predictive value (0.94) are similar to CT and suggest that if the DTS is normal patients do not need further assessment with CT with significant potential dose savings. • 50% of suspected lesions were resolved with CXR, this improved to 96% with DTS. - Abstract: Objectives: To assess the capability of digital tomosynthesis (DTS) of the chest compared to a postero-anterior (PA) and lateral chest radiograph (CXR) in the diagnosis of suspected but unconfirmed pulmonary nodules and hilar lesions detected on a CXR. Computed tomography (CT) was used as the reference standard. Materials and method: 78 patients with suspected non-calcified pulmonary nodules or hilar lesions on their CXR were included in the study. Two radiologists, blinded to the history and CT, prospectively analysed the CXR (PA and lateral) and the DTS images using a picture archiving and communication workstation and were asked to designate one of two outcomes: true intrapulmonary lesion or false intrapulmonary lesion. A CT of the chest performed within 4 weeks of the CXR was used as the reference standard. Inter-observer agreement and time to report the modalities

  19. New digital techniques applied to A and Z identification using pulse shape discrimination of silicon detector current signals

    Energy Technology Data Exchange (ETDEWEB)

    Barlini, S. [LPC Caen, ENSICAEN, University of Caen, CNRS/IN2P3, Caen (France)], E-mail: barlini@fi.infn.it; Bougault, R.; Laborie, Ph.; Lopez, O.; Mercier, D. [LPC Caen, ENSICAEN, University of Caen, CNRS/IN2P3, Caen (France); Parlog, M. [LPC Caen, ENSICAEN, University of Caen, CNRS/IN2P3, Caen (France); NIPNE, RO-76900 Bucharest (Romania); Tamain, B.; Vient, E. [LPC Caen, ENSICAEN, University of Caen, CNRS/IN2P3, Caen (France); Chevallier, E.; Chbihi, A.; Jacquot, B. [GANIL, CEA/DSM-CNRS/IN2P3, Caen (France); Kravchuk, V.L. [INFN-LNL, I-35020 Legnaro, Padova (Italy)

    2009-03-11

    Extending pulse shape discrimination (PSD) to digitized signals is one of the most promising methods to identify particles stopped in a detector. Using the CIME accelerator in the GANIL laboratory, a measurement campaign was done to collect data corresponding to different charges, masses and energies of implanted ions. These data are used to develop an algorithm capable to discriminate the different particles both in mass and charge. In this experiment, a 300{mu}m n-TD reverse mounted Si detector was used. These studies on PSD are part of the FAZIA R and D, a research and development project aiming at building a new 4{pi} array for isospin nuclear physics.

  20. Use and imaging performance of CMOS flat panel imager with LiF/ZnS(Ag) and Gadox scintillation screens for neutron radiography

    Science.gov (United States)

    Cha, B. K.; kim, J. Y.; Kim, T. J.; Sim, C.; Cho, G.; Lee, D. H.; Seo, C.-W.; Jeon, S.; Huh, Y.

    2011-01-01

    In digital neutron radiography system, a thermal neutron imaging detector based on neutron-sensitive scintillating screens with CMOS(complementary metal oxide semiconductor) flat panel imager is introduced for non-destructive testing (NDT) application. Recently, large area CMOS APS (active-pixel sensor) in conjunction with scintillation films has been widely used in many digital X-ray imaging applications. Instead of typical imaging detectors such as image plates, cooled-CCD cameras and amorphous silicon flat panel detectors in combination with scintillation screens, we tried to apply a scintillator-based CMOS APS to neutron imaging detection systems for high resolution neutron radiography. In this work, two major Gd2O2S:Tb and 6LiF/ZnS:Ag scintillation screens with various thickness were fabricated by a screen printing method. These neutron converter screens consist of a dispersion of Gd2O2S:Tb and 6LiF/ZnS:Ag scintillating particles in acrylic binder. These scintillating screens coupled-CMOS flat panel imager with 25x50mm2 active area and 48μm pixel pitch was used for neutron radiography. Thermal neutron flux with 6x106n/cm2/s was utilized at the NRF facility of HANARO in KAERI. The neutron imaging characterization of the used detector was investigated in terms of relative light output, linearity and spatial resolution in detail. The experimental results of scintillating screen-based CMOS flat panel detectors demonstrate possibility of high sensitive and high spatial resolution imaging in neutron radiography system.

  1. GELATIO: a general framework for modular digital analysis of high-purity Ge detector signals

    CERN Document Server

    Agostini, M; Zavarise, P; Volynets, O

    2011-01-01

    GELATIO is a new software framework for advanced data analysis and digital signal processing developed for the GERDA neutrinoless double beta decay experiment. The framework is tailored to handle the full analysis flow of signals recorded by high purity Ge detectors and photo-multipliers from the veto counters. It is designed to support a multi-channel modular and flexible analysis, widely customizable by the user either via human-readable initialization files or via a graphical interface. The framework organizes the data into a multi-level structure, from the raw data up to the condensed analysis parameters, and includes tools and utilities to handle the data stream between the different levels. GELATIO is implemented in C++. It relies upon ROOT and its extension TAM, which provides compatibility with PROOF, enabling the software to run in parallel on clusters of computers or many-core machines. It was tested on different platforms and benchmarked in several GERDA-related applications. A stable version is pr...

  2. Standard practice for digital detector array performance evaluation and long-term stability

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This practice describes the evaluation of DDA systems for industrial radiology. It is intended to ensure that the evaluation of image quality, as far as this is influenced by the DDA system, meets the needs of users, and their customers, and enables process control and long term stability of the DDA system. 1.2 This practice specifies the fundamental parameters of Digital Detector Array (DDA) systems to be measured to determine baseline performance, and to track the long term stability of the DDA system. 1.3 The DDA system performance tests specified in this practice shall be completed upon acceptance of the system from the manufacturer and at intervals specified in this practice to monitor long term stability of the system. The intent of these tests is to monitor the system performance for degradation and to identify when an action needs to be taken when the system degrades by a certain level. 1.4 The use of the gages provided in this standard is mandatory for each test. In the event these tests or ga...

  3. Development of a Microcontroller Based Digital Breath Alcohol Threshold Limit Detector

    Directory of Open Access Journals (Sweden)

    Jonathan A. Enokela

    2016-06-01

    Full Text Available In many countries of the world, a major course of vehicle accidents is attributed to driving under the influence of alcohol. Various solutions to this problem have been found by the use of different types of technology. The digital breath alcohol threshold limit detector presented in this work correlates the breath alcohol concentration (BrAC to the blood alcohol concentration (BAC and determines the amount of BrAC required for safe driving. This is achieved by using a stable and sensitive gas sensor to detect the amount of alcohol, particularly ethanol, in the breath of the driver. The output of the sensor, in form of voltage, is processed by a microcontroller that warns the driver in both visual and audible forms if it is safe to drive or not. The electronic circuit including the sensor, buzzer, and liquid crystal display (LCD, was implemented. The sensor was calibrated using ethanol solutions in the range that includes legal limits allowed for driving. The program for the microcontroller was developed using MikroC development environment and hardware simulation was carried out with the aid of Proteus Design Suite version 8.0. The project achieves the objective of being a screening type device that is meant to detect the presence of alcohol beyond a threshold value and to give appropriate advice to the vehicle driver. The device may also be useful to regulatory agencies that monitor the amount of alcohol intake by drivers.

  4. Design Of Digital Configurable Error Free Frequency Detector Using Strobe Signal.

    Directory of Open Access Journals (Sweden)

    Sayannika Banik,

    2014-04-01

    Full Text Available This paper presents a glitch free module using strobe signal which overcomes the limitation of delay mismatch in a wide range of applications. The proposed strobe signal logic can control the occurrence of glitch at both the rising edge and falling edge of the circuit. The theoretical demonstration of the glitch free operation of the proposed strobe signal module is also derived in the paper. The previously proposed digitally controlled delay lines (DCDL has been compared to this technology. Simulation results show the correctness of the module with no delay mismatch with respect to the previously proposed DCDL. As an example application, the strobe signal logic is used in configurable error free frequency detector (a frequency counter which can control the occurrence of glitch during the sudden modulation of the frequency. The employ of the proposed strobe signal can hold the operation of the gate for a specific time until the other gate completes its operation so that there is no delay mismatch.

  5. Toward practical 3D radiography of pipeline girth welds

    Energy Technology Data Exchange (ETDEWEB)

    Wassink, Casper, E-mail: casper.wassink@applusrtd.com [Applus RTD Chief Scientist, Rivium 1e straat 80, 2909 LE Capelle a/d IJssel (Netherlands); Hol, Martijn, E-mail: martijn.hol@applusrtd.com; Flikweert, Arjan, E-mail: martijn.hol@applusrtd.com; Meer, Philip van, E-mail: martijn.hol@applusrtd.com [Applus RTD Technological Center, Delftweg 144, 3046 NC Rotterdam (Netherlands)

    2015-03-31

    Digital radiography has made its way into in-the-field girth weld testing. With recent generations of detectors and x-ray tubes it is possible to reach the image quality desired in standards as well as the speed of inspection desired to be competitive with film radiography and automated ultrasonic testing. This paper will show the application of these technologies in the RTD Rayscan system. The method for achieving an image quality that complies with or even exceeds prevailing industrial standards will be presented, as well as the application on pipeline girth welds with CRA layers. A next step in development will be to also achieve a measurement of weld flaw height to allow for performing an Engineering Critical Assessment on the weld. This will allow for similar acceptance limits as currently used with Automated Ultrasonic Testing of pipeline girth welds. Although a sufficient sizing accuracy was already demonstrated and qualified in the TomoCAR system, testing in some applications is restricted to time limits. The paper will present some experiments that were performed to achieve flaw height approximation within these time limits.

  6. Digital signal processing for a thermal neutron detector using ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs

    OpenAIRE

    Mosset, J. -B.; Stoykov, A.; Greuter, U.; Hildebrandt, M.; Schlumpf, N.

    2015-01-01

    We present a digital signal processing system based on a photon counting approach which we developed for a thermal neutron detector consisting of ZnS(Ag):6LiF scintillating layers read out with WLS fibers and SiPMs. Three digital filters have been evaluated: a moving sum, a moving sum after differentiation and a digital CR-RC^4 filter. The performances of the detector with these filters are presented. A full analog signal processing using a CR-RC^4 filter has been emulated digitally. The dete...

  7. Full breast digital mammography with an amorphous silicon-based flat panel detector: Physical characteristics of a clinical prototype

    OpenAIRE

    2000-01-01

    The physical characteristics of a clinical prototype amorphous silicon-based flat panel imager for full-breast digital mammography have been investigated. The imager employs a thin thallium doped CsI scintillator on an amorphous silicon matrix of detector elements with a pixel pitch of 100 μm. Objective criteria such as modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), and noise equivalent quanta were employed for this evaluation. The presampling MT...

  8. Breast cancer detection rates using four different types of mammography detectors

    Energy Technology Data Exchange (ETDEWEB)

    Mackenzie, Alistair; Warren, Lucy M.; Dance, David R.; Young, Kenneth C. [Royal Surrey County Hospital, National Coordinating Centre for the Physics in Mammography (NCCPM), Guildford (United Kingdom); University of Surrey, Department of Physics, Guildford (United Kingdom); Wallis, Matthew G. [Cambridge University Hospitals NHS Foundation Trust, Cambridge (United Kingdom); NIHR Cambridge Biomedical Research Centre, Cambridge Breast Unit, Cambridge (United Kingdom); Cooke, Julie [Jarvis Breast Screening and Diagnostic Centre, Guildford (United Kingdom); Given-Wilson, Rosalind M. [St George' s Healthcare NHS Trust, Department of Radiology, London (United Kingdom); Chakraborty, Dev P. [University of Pittsburgh, Department of Radiology, Pittsburgh, PA (United States); Halling-Brown, Mark D. [Royal Surrey County Hospital, Scientific Computing, Department of Medical Physics, Guildford (United Kingdom); Looney, Padraig T. [Royal Surrey County Hospital, National Coordinating Centre for the Physics in Mammography (NCCPM), Guildford (United Kingdom)

    2016-03-15

    To compare the performance of different types of detectors in breast cancer detection. A mammography image set containing subtle malignant non-calcification lesions, biopsy-proven benign lesions, simulated malignant calcification clusters and normals was acquired using amorphous-selenium (a-Se) detectors. The images were adapted to simulate four types of detectors at the same radiation dose: digital radiography (DR) detectors with a-Se and caesium iodide (CsI) convertors, and computed radiography (CR) detectors with a powder phosphor (PIP) and a needle phosphor (NIP). Seven observers marked suspicious and benign lesions. Analysis was undertaken using jackknife alternative free-response receiver operating characteristics weighted figure of merit (FoM). The cancer detection fraction (CDF) was estimated for a representative image set from screening. No significant differences in the FoMs between the DR detectors were measured. For calcification clusters and non-calcification lesions, both CR detectors' FoMs were significantly lower than for DR detectors. The calcification cluster's FoM for CR NIP was significantly better than for CR PIP. The estimated CDFs with CR PIP and CR NIP detectors were up to 15 % and 22 % lower, respectively, than for DR detectors. Cancer detection is affected by detector type, and the use of CR in mammography should be reconsidered. (orig.)

  9. Study of digital pulse shape discrimination method for n-{\\gamma} separation of EJ-301 liquid scintillation detector

    CERN Document Server

    Wan, Bo; Chen, Liang; Ge, Honglin; Ma, Fei; Zhang, Hongbin; Ju, Yongqin; Zhang, Yanbin; Li, Yanyan; Xu, Xiaowei

    2015-01-01

    A digital pulse shape discrimination system based on a programmable module NI-5772 has been established and tested with EJ-301 liquid scintillation detector. The module was operated by means of running programs developed in LabVIEW with the sampling frequency up to 1.6GS/s. Standard gamma sources 22Na, 137Cs and 60Co were used to calibrate the EJ-301 liquid scintillation detector, and the gamma response function has been obtained. Digital algorithms for charge comparison method and zero-crossing method have been developed. The experimental results showed that both digital signal processing (DSP) algorithms could discriminate neutrons from gamma-rays. Moreover, the zero-crossing method shows better n-{\\gamma} discrimination at 80 keVee and lower, whereas the charge comparison method gives better results at higher thresholds. In addition, the figure-of-merit (FOM) of two different dimension detectors were extracted at 9 energy thresholds, and it was found that the smaller one presented a better n-{\\gamma} separ...

  10. Advantages obtained in radiation protection when using computerized radiography tests - CR (digital) in processing plants; Vantagens obtidas em radioprotecao quando do uso do ensaio de radiografia computadorizada - RC (digital) em plantas de processo

    Energy Technology Data Exchange (ETDEWEB)

    Jose, Joao Carlos Videira; Milani, Hilton Sergio B.; Paes, Eliseu Almir de Oliveira; Boita, Mario de [ARCtest Servicos Tecnicos de Inspecao e Manutencao Industrial Ltda., Sao Paulo, SP (Brazil)]. E-mail: tecnica@arctest.com.br; Souza, Laercio de; Serra, Flavio Augusto dos Santos [PETROBRAS, Paulinia, SP, RJ (Brazil). Refinaria do Planalto Paulista (REPLAN)]. E-mails: laerciosouza@petrobras.com.br; serra@petrobras.com.br

    2002-07-01

    During the year 2000, the ARCtest initiated the development of the research for adapting the Computerized Radiography - CR, originally conceived for medical applications, for the Industry, trying initially to attend the requirements of the processing plants, concerning to the detection of deterioration mechanisms (evaluation of the piping integrity). Due to the obtained excellent results, the possibility of utilization the Computerized Radiography - CR in the radiographic inspection were studied during the shutdown of the Catalytic Cracking Unit of the PETROBRAS-REPLAN, specifically in the replacement of the CO boiler superheater, where a large number of the small diameter welded joints have been predicted.

  11. On the response of a europium doped phosphor-coated CMOS digital imaging detector

    Energy Technology Data Exchange (ETDEWEB)

    Seferis, I.E. [Department of Medical Physics, Faculty of Medicine, University of Patras, 26500 Patras (Greece); Michail, C.M.; Valais, I.G.; Fountos, G.P.; Kalyvas, N.I. [Department of Medical Instruments Technology, Technological Educational Institute (TEI) of Athens, Agios Spyridonos, 12210 Athens (Greece); Stromatia, F. [Department of Radiology and Nuclear Medicine, “IASO” General Hospital, Mesogion 264, 15562 Holargos (Greece); Oikonomou, G. [Department of Medical Radiological Technology, Faculty of Health and Caring Professions, Technological Educational Institute (TEI) of Athens, Agios Spyridonos, 12210 Athens (Greece); Kandarakis, I.S., E-mail: kandarakis@teiath.gr [Department of Medical Instruments Technology, Technological Educational Institute (TEI) of Athens, Agios Spyridonos, 12210 Athens (Greece); Panayiotakis, G.S. [Department of Medical Physics, Faculty of Medicine, University of Patras, 26500 Patras (Greece)

    2013-11-21

    Purpose: The purpose of the present study was to assess the information content of a high resolution active pixel CMOS imaging sensor coupled to Gd{sub 2}O{sub 2}S:Eu phosphor screens in terms of single index image quality metrics such as the information capacity (IC) and the noise equivalent passband (Ne). Methods: The CMOS sensor was coupled to two Gd{sub 2}O{sub 2}S:Eu scintillator screens with coating thicknesses of 33.3 and 65.1 mg/cm{sup 2}. IC and Ne were obtained by means of experimentally determined parameters such as the modulation transfer function (MTF), the detective quantum efficiency (DQE) and the noise equivalent quanta (NEQ). Measurements were performed using the standard IEC-RQA5 radiation beam quality (70 kVp) and a W/Rh beam quality (28 kVp). Results: It was found that the detector response function was linear for the exposure ranges under investigation. At 70 kVp, under the RQA 5 conditions IC values were found to range between 1730 and 1851 bits/mm{sup 2} and Ne values were found between 2.28 and 2.52 mm{sup −1}. At 28 kVp the corresponding IC values were found to range between 2535 and 2747 bits/mm{sup 2}, while the Ne values were found between 5.91 and 7.09 mm{sup −1}. Conclusion: IC and Ne of the red emitting phosphor/CMOS sensor combination were found with high values suggesting an acceptable imaging performance in terms of information content and sharpness, for X-ray digital imaging. -- Highlights: •Gd{sub 2}O{sub 2}S:Eu/CMOS combination has comparable image quality parameters to Gd{sub 2}O{sub 2}S:Tb/CMOS. •Information capacity was found with high values suggesting an acceptable imaging performance. •Red emitting phosphors coupled to silicon based optical sensors could be used in developing efficient imaging detectors.

  12. The effect of amorphous selenium detector thickness on dual-energy digital breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hu, Yue-Houng, E-mail: yuehoung.hu@gmail.com; Zhao, Wei [Department of Radiology, State University of New York at Stony Brook, L-4 120 Health Sciences Center, Stony Brook, New York 11794-8460 (United States)

    2014-11-01

    Purpose: Contrast enhanced (CE) imaging techniques for both planar digital mammography (DM) and three-dimensional (3D) digital breast tomosynthesis (DBT) applications requires x-ray photon energies higher than the k-edge of iodine (33.2 keV). As a result, x-ray tube potentials much higher (>40 kVp) than those typical for screening mammography must be utilized. Amorphous selenium (a-Se) based direct conversion flat-panel imagers (FPI) have been widely used in DM and DBT imaging systems. The a-Se layer is typically 200 μm thick with quantum detective efficiency (QDE) >87% for x-ray energies below 26 keV. However, QDE decreases substantially above this energy. To improve the object detectability of either CE-DM or CE-DBT, it may be advantageous to increase the thickness (d{sub Se}) of the a-Se layer. Increasing the d{sub Se} will improve the detective quantum efficiency (DQE) at the higher energies used in CE imaging. However, because most DBT systems are designed with partially isocentric geometries, where the gantry moves about a stationary detector, the oblique entry of x-rays will introduce additional blur to the system. The present investigation quantifies the effect of a-Se thickness on imaging performance for both CE-DM and CE-DBT, discussing the effects of improving photon absorption and blurring from oblique entry of x-rays. Methods: In this paper, a cascaded linear system model (CLSM) was used to investigate the effect of d{sub Se} on the imaging performance (i.e., MTF, NPS, and DQE) of FPI in CE-DM and CE-DBT. The results from the model are used to calculate the ideal observer signal-to-noise ratio, d′, which is used as a figure-of-merit to determine the total effect of increasing d{sub Se} for CE-DM and CE-DBT. Results: The results of the CLSM show that increasing d{sub Se} causes a substantial increase in QDE at the high energies used in CE-DM. However, at the oblique projection angles used in DBT, the increased length of penetration through a

  13. National data analysis of general radiography projection method in medical imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Seo, Deok Nam; Choi, In Seok [Dept. of Bio-Convergence Engineering, Korea University Graduate School, Seoul (Korea, Republic of); and others

    2014-09-15

    According to database of medical institutions of health insurance review and assessment service in 2013, 1,118 hospitals and clinics have department of radiology in Korea. And there are CT, fluoroscopic and general radiographic equipment in those hospitals. Above all, general radiographic equipment is the most commonly used in the radiology department. And most of the general radiographic equipment are changing the digital radiography system from the film-screen types of the radiography system nowadays. However, most of the digital radiography department are used the film-screen types of the radiography system. Therefore, in this study, we confirmed present conditions of technical items for general radiography used in hospital and research on general radiographic techniques in domestic medical institutions. We analyzed 26 radiography projection method including chest, skull, spine and pelvis which are generally used in the radiography department.

  14. Digital signal processing for a thermal neutron detector using ZnS(Ag):{sup 6}LiF scintillating layers read out with WLS fibers and SiPMs

    Energy Technology Data Exchange (ETDEWEB)

    Mosset, J.-B., E-mail: jean-baptiste.mosset@psi.ch; Stoykov, A.; Greuter, U.; Hildebrandt, M.; Schlumpf, N.

    2016-07-11

    We present a digital signal processing system based on a photon counting approach which we developed for a thermal neutron detector consisting of ZnS(Ag):{sup 6}LiF scintillating layers read out with WLS fibers and SiPMs. Three digital filters have been evaluated: a moving sum, a moving sum after differentiation and a digital CR-RC{sup 4} filter. The performances of the detector with these filters are presented. A full analog signal processing using a CR-RC{sup 4} filter has been emulated digitally. The detector performance obtained with this analog approach is compared with the one obtained with the best performing digital approach. - Highlights: • Application of digital signal processing for a SiPM-based ZnS:6LiF neutron detector. • Optimisation of detector performances with 3 different digital filters. • Comparison with detector performances with a full analog signal processing.

  15. Development of an high resolution neutron spectroscopy system using a diamond detector and a remote digital acquisition methodology

    Energy Technology Data Exchange (ETDEWEB)

    Pillon, Mario, E-mail: mario.pillon@enea.it [Associazione EURATOM-ENEA sulla Fusione, ENEA C.R. Frascati, via E. Fermi, 45, 00044 Frascati (Rome) (Italy); Andreoli, Fabrizio; Angelone, Maurizio [Associazione EURATOM-ENEA sulla Fusione, ENEA C.R. Frascati, via E. Fermi, 45, 00044 Frascati (Rome) (Italy); Milocco, Alberto [University of Milano Bicocca, Piazza della Scienza 3, 20126 Milano (Italy); Cardarelli, Roberto [Istituto Nazionale di Fisica Nucleare, Sezione Tor Vergata, via della Ricerca Scientifica, 1, 00133 Rome (Italy)

    2014-10-15

    Highlights: •We studied the response of a diamond detector connected, to a prototype preamplifier developed by our group. •The response was studied for quasi mono-energetic neutron energies between 5 and 20.5 MeV. •About 50 m of coaxial cable was interposed between the detector and the preamplifier. •This technique was developed in order to have the electronics located far from the high radiation zone. •Such approach could be interesting for hash environment like the Radial Neutron Camera of ITER. -- Abstract: The need of performing high resolution fast neutron spectroscopy in a very harsh environment like that of the Radial Neutron Camera (RNC) of ITER, requires to develop new detectors and methodologies. Diamond detectors have been proved to be excellent candidates but the electronics needs a substantial improvement. Because of the high radiation level and the temperatures expected near the detector positions in the RNC, the electronics must be placed several meters away. A novel Fast Charge Amplifier (FCA) was developed that, connected to a diamond detector using several tens of meters of low capacitance coaxial cable, is able to produce fast output signals suitable to be processed by digital electronics. These fast output signals allow to operate at high count rates avoiding pile-up problems. This novel amplifier connected to a digitizer is here tested in the neutron energy range from 5 to 20.5 MeV using the mono-energetic neutrons produced by the Van de Graaff (VdG) accelerator of the EC-JRC-IRMM and by the PTB cyclotron. From the measurements the experimental response functions of the diamond detector at different neutron energies were obtained. The shape of the response functions have been compared with that predicted with a routine which was implemented for the Monte Carlo code MCNPX with the scope to validate the calculations versus the experimental data. The goal is to develop a tool which allows to calculate the diamond detector response

  16. Coincidence measurements in {alpha}/{beta}/{gamma} spectrometry with phoswich detectors using digital pulse shape discrimination analysis

    Energy Technology Data Exchange (ETDEWEB)

    Celis, B. de [University of Leon, Escuela de Ingenieria Industrial, Leon 24071 (Spain)], E-mail: bcelc@unileon.es; Fuente, R. de la [University of Leon, Escuela de Ingenieria Industrial, Leon 24071 (Spain); Williart, A. [UNED, F. Ciencias Fisicas, Madrid 28040 (Spain); Celis Alonso, B. de [King' s College London, IoP, De Crespigny Park, London SE5 8AF (United Kingdom)

    2007-09-21

    A novel system has been developed for the detection of low radioactivity levels using coincidence techniques. The device combines a phoswich detector for {alpha}/{beta}/{gamma} ray recognition with a fast digital card for electronic pulse analysis. The detector is able to discriminate different types of radiation in a mixed {alpha}/{beta}/{gamma} field and can be used in a coincidence mode by identifying the composite signal produced by the simultaneous detection of {beta} particles in a plastic scintillator and {gamma} rays in an NaI(Tl) scintillator. Use of a coincidence technique with phoswich detectors was proposed recently to verify the Nuclear Test Ban Treaty, which made it necessary to monitor the low levels of xenon radioisotopes produced by underground nuclear explosions. Previous studies have shown that combining CaF{sub 2}(Eu) for {beta} ray detection and NaI(Tl) for {gamma} ray detection makes it difficult to identify the coincidence signals because of the similar fluorescence decay times of the two scintillators. With the device proposed here, it is possible to identify the coincidence events owing to the short fluorescence decay time of the plastic scintillator. The sensitivity of the detector may be improved by employing liquid scintillators, which allow low radioactivity levels from actinides to be measured when present in environmental samples. The device developed is simpler to use than conventional coincidence equipment because it uses a single detector and electronic circuit, and it offers fast and precise analysis of the coincidence signals by employing digital pulse shape analysis.

  17. Muon radiography for exploration of Mars geology

    Directory of Open Access Journals (Sweden)

    S. Kedar

    2013-06-01

    Full Text Available Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays to image the interior of large-scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  18. Muon radiography for exploration of Mars geology

    Directory of Open Access Journals (Sweden)

    S. Kedar

    2012-10-01

    Full Text Available Muon radiography is a technique that uses naturally occurring showers of muons (penetrating particles generated by cosmic rays to image the interior of large scale geological structures in much the same way as standard X-ray radiography is used to image the interior of smaller objects. Recent developments and application of the technique to terrestrial volcanoes have demonstrated that a low-power, passive muon detector can peer deep into geological structures up to several kilometers in size, and provide crisp density profile images of their interior at ten meter scale resolution. Preliminary estimates of muon production on Mars indicate that the near horizontal Martian muon flux, which could be used for muon radiography, is as strong or stronger than that on Earth, making the technique suitable for exploration of numerous high priority geological targets on Mars. The high spatial resolution of muon radiography also makes the technique particularly suited for the discovery and delineation of Martian caverns, the most likely planetary environment for biological activity. As a passive imaging technique, muon radiography uses the perpetually present background cosmic ray radiation as the energy source for probing the interior of structures from the surface of the planet. The passive nature of the measurements provides an opportunity for a low power and low data rate instrument for planetary exploration that could operate as a scientifically valuable primary or secondary instrument in a variety of settings, with minimal impact on the mission's other instruments and operation.

  19. Pilot study: digital subtraction radiography as a tool to assess alveolar bone changes in periodontitis patients under treatment with subantimicrobial doses of doxycycline

    NARCIS (Netherlands)

    A.D. Goren; S.M. Dunn; M. Wolff; P.F. van der Stelt; D.C. Colosi; L.M. Golub

    2008-01-01

    Background Subtle changes in marginal alveolar bone level can be demonstrated using digital subtraction of sequential radiographs. Objective We aimed to evaluate the practical application of geometrically corrected digital subtraction in a clinical study of alveolar bone response to a drug previousl

  20. Influence of x-ray energy spectrum, contrasting detail and detector on the signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) in projection radiography

    Energy Technology Data Exchange (ETDEWEB)

    Sandborg, Michael; Carlsson, G.A. (Linkoeping Univ. (Sweden). Dept. of Radiation Physics)

    1992-06-01

    A lower limit to patient irradiation in diagnostic radiology is set by the fundamental stochastics of the energy imparted to the image receptor (quantum noise). Image quality is investigated here and expressed in terms of the signal-to-noise ratio due to quantum noise. The Monte Carlo method is used to calculate signal-to-noise ratios (SNR{sub {Delta}S}) and detective quantum efficiencies (DQE{sub {Delta}S}) in imaging thin contrasting details of air, fat, bone and iodine within a water phantom using x-ray spectra (40-140 kV) and detectors of CsI, BaFCl and Gd{sub 2}O{sub 2}S. The atomic composition of the contrasting detail influences considerably the values of SNR{sub {Delta}S} due to the different modulations of the energy spectra of primary photons passing beside and through the contrasting detail. (author).

  1. Assessment of enamel demineralization using conventional, digital, and digitized radiography Avaliação da desmineralização do esmalte por meio de radiografias convencional, digital e digitalizada

    Directory of Open Access Journals (Sweden)

    Rívea Inês Ferreira

    2006-04-01

    Full Text Available This experimental research aimed at evaluating the accuracy of enamel demineralization detection using conventional, digital, and digitized radiographs, as well as to compare radiographs and logarithmically contrast-enhanced subtraction images. Enamel subsurface demineralization was induced on one of the approximal surfaces of 49 sound third molars. Standardized radiographs of the teeth were taken prior to and after the demineralization phase with three digital systems - CygnusRay MPS®, DenOptix® and DIGORA® - and InSight® film. Three radiologists interpreted the pairs of conventional, digital, and digitized radiographs in two different occasions. Logarithmically contrast-enhanced subtraction images were examined by a fourth radiologist only once. Radiographic diagnosis was validated by cross-sectional microhardness profiling in the test areas of the approximal surfaces. Accuracy was estimated by Receiver Operating Characteristic (ROC analysis. Chi-square test, at a significance level of 5%, was used to compare the areas under the ROC curves (Az calculated for the different imaging modalities. Concerning the radiographs, the DenOptix® system (Az = 0.91 and conventional radiographs (Az = 0.90 presented the highest accuracy values compared with the other three radiographic modalities. However, logarithmically contrast-enhanced subtraction images (Az = 0.98 were significantly more accurate than conventional, digital, and digitized radiographs (p = 0.0000. It can be concluded that the DenOptix® system and conventional radiographs provide better performance for diagnosing enamel subsurface demineralization. Logarithmic subtraction significantly improves radiographic detection.O objetivo desta pesquisa experimental foi investigar a acurácia da detecção de desmineralizações em esmalte por meio de radiografias convencionais, digitais e digitalizadas, e compará-las às imagens por subtração logarítmica. Foram induzidas desmineraliza

  2. Reduction of radiation dose by using digital luminescence radiography compared to conventional screen film system with grid cassette; Reduktion der Strahlendosis mittels Speicherfolienradiographie im Vergleich zum konventionellen Film-Folien-System mit Rasterkassette am Schaedelphantom

    Energy Technology Data Exchange (ETDEWEB)

    Heyne, J.P.; Merbold, H.; Neumann, R.; Freesmeyer, M.; Jonetz-Mentzel, L.; Kaiser, W.A. [Friedrich-Schiller-Univ. Jena, Inst. fuer Diagnostische und Interventionelle Radiologie (Germany); Sehner, J. [AGFA-Deutschland, Vertriebsgesellschaft (Germany)

    1999-07-01

    Purpose: How much can the radiation dose be reduced for skull radiography by using digital luminescence radiography (DLR) compared to a conventional screen film system with a grid cassette? Methods and Materials: A skull phantom (3M) was X-rayed in anterior-posterior orientation using both a conventional screen film system with grid cassette and DLR (ADC-70, Agfa). The tube current time product (mAs) was diminished gradually while keeping the voltage constant. The surface entrance dose was measured by a sensor of Dosimax (Wellhoefer). Five investigators evaluated the images by characteristic and critical features, spatial resolution and contrast. Results: The surface entrance dose at 73 kV/22 mAs was 0,432 mGy in conventional screen film system and 0,435 mGy in DLR. The images could be evaluated very well down to an average dose of 71% (0,308 mGy; SD 0,050); sufficient images were obtained down to an average dose of 31% (0,136 mGy; SD 0,065). The resolution of the line pairs were reduced down to a 2 levels depending on the investigator. Contrast was assessed as being very good to sufficient. The acceptance of the postprocessed images (MUSICA-software) was individually different and resultde in an improvement of the assessment of bone structures an contrast in higher dose ranges only. Conclusion: For the sufficient assessment of a possible fracture/of paranasal sinuses/of measurement the skull the dose can be reduced to at least 56% (31%; SD 14,9%)/40% (27%; SD 9,3%)/18% (14%; SD 4,4%). Digital radiography allows question-referred exposure parameters with clearly reduced dose, so e.g. for fracture exclusion 73 kV/12,5 mAs and to skull measurement 73 kV/4 mAs. (orig.) [Deutsch] Ziel: Wie weit kann unter Einsatz der rasterlosen Speicherfolienradiographie bei einer Schaedelaufnahme die Strahlendosis im Vergleich zum Film-Folien-System (FFS) mit Rasterkassette (RK) fragestellungsbezogen gesenkt werden? Material und Methode: Ein Schaedelphantom (3M) wurde konventionell

  3. Modern digital plain-radiography of the whole spine in scoliosis patients. Dose reduction and quality criteria; Moderne digitale Radiografie der Ganzwirbelsaeule bei Skoliose. Dosisreduktion und Qualitaetskriterien

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, Jost Karsten; Stiller, W.; Kauczor, H.U.; Weber, M.A. [Universitaetsklinik Heidelberg (Germany). Diagnostische und Interventionelle Radiologie; Wiedenhoefer, B.; Ewerbeck, V. [Universitaetsklinik Heidelberg (Germany). Orthopaedische Universitaetsklinik; Burkholder, I. [StaBiL, Statistische und Biometrische Loesungen, Zweibruecken (Germany)

    2013-01-15

    To reduce the radiation exposure of plain radiographs of the entire spine depending on specific indications, since these are frequently performed examinations of children and young adults with scoliosis and to determine objective quality control criteria to ensure accurate assessment. In this prospective randomized study 323 patients underwent plain-radiography of the entire spine with standard and 50 % reduced dose. In an experimental pilot-study this target-dose was determined using an Alderson-Phantom. The evaluation of the experimental radiographs, as well as, the randomized plain-radiographs was conducted using the following criteria: endplates (Cobb-angle), spinal process and pedicel (rotation), lateral margin of the vertebral body (lateral alignment), identification of C7 / S1 (perpendicular). Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If one single criteria was evaluated with a score of 3 or more points or more than 2 criteria with 2 points, the radiograph was scored as ''not assessable''. The statistical analysis was conducted as a non-inferiority-trial. Seven (2.4 %) of the 290 examined x-rays were scored as not assessable. There was no statistic inferiority between the examinations with standard or reduced dose, while singular assessment of the defined criteria was likewise dose-independent. Plain-radiography of the total spine in patients with scoliosis can be performed with a dose reduction of 50 % without a loss of validity. The obtained quality control criteria were clinically applicable. (orig.)

  4. Single-exposure dual-energy computed radiography.

    Science.gov (United States)

    Stewart, B K; Huang, H K

    1990-01-01

    This paper focuses on analysis and development of a single-exposure dual-energy digital radiographic method using computed radiography (Fuji FCR-101 storage phosphor system). A detector sandwich consisting of storage phosphor imaging plates and an interdetector filter is used. The goal of this process is to provide a simple dual-energy method using typical plane-projection radiographic equipment and techniques. This approach exploits the transparency of the storage phosphor plates, using radiographic information that would be otherwise lost, to provide energy selective information essentially as a by-product of the radiographic examination. In order to effectively make use of the large dynamic range of the storage phosphor imaging plates (10,000:1), a computed radiography image reading mode of fixed analog-to-digital converter gain and variable photomultiplier sensitivity provides image data which can be related to relative incident exposure for export to the decomposition algorithm. Scatter rejection requirements necessitated crossed 12:1 grids for a field size of 36 x 36 cm. Optimal technique parameters obtained from computer simulation through minimization of the aluminum and Plexiglas equivalent image uncertainty under conditions of constant absorbed does resulted as: 100 kVp using a 0.15-mm-thick tin (Sn) interdetector filter for the lung field. This yields a surface exposure of 23 mR and a surface absorbed dose of 0.26 mGy for a 23-cm-thick chest. Clinical application in evaluation of the solitary pulmonary nodule is discussed, along with an image set demonstrating this application.

  5. Performance of a flat-panel detector in the detection of artificial erosive changes: comparison with conventional screen-film and storage-phosphor radiography

    Energy Technology Data Exchange (ETDEWEB)

    Ludwig, Karl; Henschel, Andreas; Bernhardt, Thomas M.; Lenzen, Horst; Wormanns, Dag; Diederich, Stefan; Heindel, Walter [Department of Clinical Radiology, University of Muenster, Albert-Schweitzer-Strasse 33, 48129, Muenster (Germany)

    2003-06-01

    Heading Abstract.The purpose of this study was to compare a large-area, direct-readout, flat-panel detector system with a conventional screen-film system, a storage-phosphor system, and a mammography screen-film system with regard to the detection of artificial bone erosions simulating rheumatoid disease, and to assess its diagnostic performance with decreasing exposure dose. Six hundred forty regions were defined in 160 metacarpophalangeal and proximal interphalangeal joint specimens from 20 monkey paws (4 regions per joint). Artificial bone erosions were created in 320 of these 640 regions. Specimens were enclosed in containers filled with water to obtain absorption and scatter radiation conditions similar to those of a human hand. Imaging was performed using a flat-panel system, a speed class 200 screen-film system, a mammography screen-film system, and a storage-phosphor system under exactly matched conditions. Different exposure doses equivalent to speed classes of S=100, 200, 400, 800, 1600, and 3200 were used. In all images the presence or absence of a lesion was assessed by three radiologists using a five-level confidence scale. Receiver operating characteristic (ROC) analysis was performed for a total of 21,120 observations (1920 for each imaging modality and exposure level) and diagnostic performance estimated by the area under the ROC curve (A{sub z}). The significance of differences in diagnostic performance was tested with analysis of variance. The ROC analysis showed A{sub z} values of 0.809 (S=200), 0.768 (S=400), 0.737 (S=800), 0.710 (S=1600), and 0.685 (S=3200) for the flat-panel system, 0.770 for the speed class 200 screen-film system, 0.781 (S=200), 0.739 (S=400), 0.724 (S=800), 0.680 (S=1600) for the storage-phosphor system, and 0.798 for the mammography screen-film system. Analysis of variance showed significant differences between different combinations of imaging modalities and exposure doses (p <0.05). The diagnostic performance of the flat

  6. Early prediction of mandibular third molar eruption/impaction using linear and angular measurements on digital panoramic radiography: A radiographic study

    OpenAIRE

    Kaur, Rachninder; Kumar, Anand C.; Garg, Ranjana; Sharma, Sugandha; Rastogi, Trisha; Gupta, Vivek Vijay

    2016-01-01

    Background: The impaction rate is higher for the third molars than for any other tooth in modern human population. This study was conducted with the aim to evaluate the validity of linear and angular measurements on the digital panoramic radiograph as a reference for early prediction of mandibular third molar eruption/impaction. Materials and Methods: Digital panoramic radiographs of 200 subjects were selected based on their status of eruption of mandibular third molars; fully erupted (Group ...

  7. A digital X-ray imaging system based on silicon strip detectors working in edge-on configuration

    Energy Technology Data Exchange (ETDEWEB)

    Bolanos, L. [CEADEN, Calle 30 502 e/ 5ta y 7ma Avenida, Playa, Ciudad Habana (Cuba); Boscardin, M. [IRST, Fondazione Bruno Kessler, Via Sommarive 18, Povo, 38100 Trento (Italy); Cabal, A.E. [CEADEN, Calle 30 502 e/ 5ta y 7ma Avenida, Playa, Ciudad Habana (Cuba); Diaz, M. [InSTEC, Ave. Salvador Allende esq. Luaces, Quinta de los Molinos, Ciudad Habana (Cuba); Grybos, P.; Maj, P. [Faculty of Electrical Engineering, Automatics, Computer Science and Electronics, Department of Measurement and Instrumentation, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland); Prino, F. [Istituto Nazionale di Fisica Nucleare, Sezione di Torino, Via P. Giuria 1, 10125 Torino (Italy); Ramello, L. [Dipartimento di Scienze e Tecnologie Avanzate, Universita del Piemonte Orientale, Via T. Michel 11, 15100 Alessandria (Italy)], E-mail: luciano.ramello@mfn.unipmn.it; Szczygiel, R. [Faculty of Electrical Engineering, Automatics, Computer Science and Electronics, Department of Measurement and Instrumentation, AGH University of Science and Technology, Al. Mickiewicza 30, 30-059 Cracow (Poland)

    2009-09-21

    We present the energy resolution and imaging performance of a digital X-ray imaging system based on a 512-strip silicon strip detector (SSD) working in the edge-on configuration. The SSDs tested in the system are 300 {mu}m thick with 1 or 2-cm-long strips and 100 {mu}m pitch. To ensure a very small dead area of the SSD working in edge-on configuration, the detector is cut perpendicular to the strips at a distance of only 20 {mu}m from the end of the strips. The 512-strip silicon detector is read out by eight 64-channel integrated circuits called DEDIX [Grybos et al., IEEE Trans. Nucl. Sci. NS-54 (2007) 1207]. The DEDIX IC operates in a single photon counting mode with two independent amplitude discriminators per channel. The readout electronic channel connected to a detector with effective input capacitance of about 2 pF has an average equivalent noise charge (ENC) of about 163 el. rms and is able to count 1 Mcps of average rate of input pulses. The system consisting of 512 channels has an excellent channel-to-channel uniformity-the effective threshold spread calculated to the charge-sensitive amplifier inputs is 12 el. rms (at one sigma level). With this system a few test images of a phantom have been taken in the 10-30 keV energy range.

  8. Measurement of the energy spectrum of {sup 252}Cf fission fragments using nuclear track detectors and digital image processing

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, G.; Golzarri, J. I. [UNAM, Instituto de Fisica, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Castano, V. M. [UNAM, Centro de Fisica Aplicada y Tecnologia Avanzada, Boulevard Juriquilla 3001, Santiago de Queretaro, 76230 Queretaro (Mexico); Gaso, I. [ININ, Carretera Mexico-Toluca s/n, Ocoyoacac 52750, Estado de Mexico (Mexico); Mena, M.; Segovia, N. [UNAM, Instituto de Geofisica, Circuito de la Investigacion Cientifica, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2010-02-15

    The energy spectrum of {sup 252}Cf fission fragments was measured using nuclear track detectors and digital image analysis system. The detection material was fused silica glass. The detectors were chemically etched in an 8% HF solution. After experimenting with various etching time, it was found that the best resolution of the track diameter distribution was obtained after 30 minutes of etching. Both Gaussian and Lorentzian curves were fit to the track diameter distribution histograms and used to determine the basic parameters of the distribution of the light (N{sub L}) and heavy (N{sub H}) formed peaks and the minimum of the central valley (N{sub V}). Advantages of the method presented here include the fully-automated analysis process, the low cost of the nuclear track detectors and the simplicity of the nuclear track method. The distribution resolution obtained by this method is comparable with the resolution obtained by electronic analysis devices. The descriptive variables calculated were very close to those obtained by other methods based on the use of semiconductor detectors. (Author)

  9. A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors.

    Science.gov (United States)

    Acciavatti, Raymond J; Maidment, Andrew D A

    2010-12-01

    , the difference in NPS and DQE between the two detector types is found to increase with the blurring of the x-ray converter. Ultimately, the expression for the additive white noise of the photon counter is compared against the expression for electronic noise and secondary quantum noise in an energy integrator. Thus, a method is provided to determine the average secondary quanta that the energy integrator must produce for each x ray to have superior DQE to a photon counter with the same PSF. This article develops analytical models of OTF, NPS, and DQE for energy integrating and photon counting digital x-ray detectors. While many subtleties of real imaging systems have not been modeled, this work is illustrative in demonstrating an additive source of white noise in photon counting detectors which has not yet been described in the literature. One benefit of this analysis is a framework for determining the average secondary quanta that an energy integrating detector must produce for each x ray to have superior DQE to competing photon counting technology.

  10. On the Performance of SVD-DWT Based Digital Video Watermarking Technique with Semi-Blind Detector

    Directory of Open Access Journals (Sweden)

    Tarzan Basaruddin

    2010-10-01

    Full Text Available This paper presents a watermarking technique for digital video. The proposed scheme is developed based on the work of Ganic and Chan which took the virtue of SVD and DWT. While the previous works of Chan has the blind detector property, our attempt is to develop a scheme with semi-blind detector, by using the merit of the DWT-SDV technique proposed by Ganic which was originally applied to still image. Overall, our experimental results show that our proposed scheme has a very good imperceptibility and is reasonably robust especially under several attacks such as compression, blurring, cropping, and sharpening.

  11. Pixel-level Analog-To-Digital Converters for Hybrid Pixel Detectors with energy sensitivity

    NARCIS (Netherlands)

    San Segundo Bello, David; Nauta, Bram; Visschers, Jan

    2000-01-01

    Single-photon counting hybrid pixel detectors have shown to be a valid alternative to other types of X-ray imaging devices due to their high sensitivity, low noise, linear behavior and wide dynamic range. One important advantage of these devices is the fact that detector and readout electronics are

  12. Design of analog-to-digital converters for energy sensitive hybrid pixel detectors

    NARCIS (Netherlands)

    San Segundo Bello, David; Nauta, Bram; Visschers, Jan

    2001-01-01

    An important feature of hybrid semiconductor pixel detectors is the fact that detector and readout electronics are manufactured separately, allowing the use of industrial state-of-the-art CMOS processes to manufacture the readout electronics. As the feature size of these processes decreases, faster

  13. Application of SLOT Scan digital radiography in adolescent scoliosis%SLOT Scan全景拼接技术对青少年脊柱侧弯畸形的应用价值

    Institute of Scientific and Technical Information of China (English)

    张殿星; 毕万利; 田军; 田野

    2012-01-01

    Objective To explore the value of SLOT Scan digital radiography in adolescent scoliosis. Methods The SLOT Scan digital radiography was applied for 85 patients with clinical diagnosis adolescent scoliosis or post-orthopaedy. All patients were underwent a P-A and lateral photography in standing, 15 patients with a dual Bending photography. The features of all images were analyzed. The congenital spine vertebral malformation were judged. The Cobb angle and Risser sign were measured, and the physiological curvature changes of thoracolumbar were analyzed. Results The thoracic and lumbar vertebra of 85 patients were displayed clearly on the P-A and lateral imaging. The cervical vertebra of 22 cases were excessive exposure. Therefore, the cervical vertebra above C5 were showed unclearly on lateral imaging. 67 cases were idiopathic scoliosis, 18 cases were congenital scoliosis. The Cobb angle of 19 cases were less than 10°,51 cases were between 10° and 40°, and 15 cases were greater than 40°. The Cobb angle change of 7 cases were less than 10°, 8 cases were more than 10° in Bending image. The Risser sign of 51 cases were less than IE degree. 34 cases were between IE and V degree. The positive value of sagittal balance were 64 cases. Negative value were 21 cases. Conclusion SLOT Scan digital radiography can provide functional images and accurate measurement. It can conduct the treatment for adolescent scoliosis patients.%目的 探讨数字化大平板X线摄影系统SLOT Scan全景拼接技术对青少年脊柱侧弯畸形的诊断价值.方法 应用SLOT Scan全景拼接技术对临床拟诊为青少年脊柱侧弯畸形与矫形术后的85例患者进行了站立位正侧位摄影检查,15例患者加照Bending位,分析其影像征象,判断有无先天性脊柱畸形,测量其Cobb角、Risser征并对胸腰椎生理曲度的变化进行分析.结果 85例患者前后位及侧位图像上均可以清晰显示胸椎、腰椎,22例颈椎过度曝光,C5以上显示

  14. Real-Time Neutron Radiography at CARR

    Institute of Scientific and Technical Information of China (English)

    HE; Lin-feng; HAN; Song-bai; WANG; Hong-li; WU; Mei-mei; WEI; Guo-hai; WANG; Yu

    2012-01-01

    <正>A real-time detector system for neutron radiography based on CMOS camera has been designed for the thermal neutron imaging facility under construction at China Advanced Research Reactor (CARR). This system is equipped with a new scientific CMOS camera with 5.5 million pixels and speed up to 100 fps at full frame. The readout noise is less than 2.4 electron per pixel. It is capable of providing

  15. Radiation dose reduction in digital plain radiography of the knee after total knee arthroplasty; Dosisreduktion in der digitalen Radiografie des Kniegelenkes nach endoprothetischem Gelenkersatz

    Energy Technology Data Exchange (ETDEWEB)

    Kloth, J.K.; Kauczor, H.U.; Weber, M.A. [University Hospital Heidelberg (Germany). Clinic for Diagnostic and Interventional Radiology; Tanner, M.; Ewerbeck, V. [University Hospital Heidelberg (Germany). Center of Orthopedics, Trauma and Spinal Cord Injury; Stiller, W. [German Cancer Research Center (DKFZ), Radiology (E010), Heidelberg (Germany); Burkholder, I. [Univ. of Applied Sciences of the Saarland, Dept. of Nursing and Health, Saarbruecken (Germany)

    2015-08-15

    To reduce radiation exposure of frequently performed radiographs of the knee in follow-up of total-knee arthroplasty ensuring accurate assessment by using objective quality control criteria. In this prospective randomized study 278 radiographs of the knee in follow-up of total-knee arthroplasty were performed with standard and 37 % reduced radiation dose. The evaluation of the plain-radiographs was conducted using the following criteria: bone-implant interface, implant-surface character, implant-implant discrimination and periarticular heterotopic ossification. Two radiologists evaluated these criteria using a score ranging from 1 (definitely assessable) to 4 (not assessable). If a single criterion had been evaluated with a score ≥ 3 or more than 2 criteria with ≥ 2 points, the radiograph was score das ''not assessable''. The study was designed as non-inferiority-trial. 100 % of examined radiographs were scored as assessable, hence no statistical inferiority between the examinations with standard and reduced dose could be observed. Singular assessment of the defined criteria was likewise dose-independent. Plain-radiography of the knee following total-knee arthroplasty can be performed with 63 % of standard dose without loss of diagnostic validity.

  16. Amorphous selenium flat panel detectors for medical applications

    Science.gov (United States)

    Zhao, Wei; Hunt, D. C.; Tanioka, Kenkichi; Rowlands, J. A.

    2005-09-01

    Different technologies for making X-ray sensitive active matrix flat-panel imagers (AMFPI) are reviewed for applications in digital radiography and fluoroscopy. Aspects of imaging performance requiring improvement are identified and potential new detector concepts addressing these issues are briefly described. The rationale is given for the investigation of a new detector concept—an indirect conversion FPI with avalanche gain—for low-dose X-ray imaging. This detector consists of an amorphous selenium (a-Se) photoconductor optically coupled to a structured cesium iodide (CsI) scintillator. Under an electric field ESe, the a-Se is sensitive to light and converts the optical photons emitted from CsI into electronic signal that can be stored and read out in the same fashion as in existing AMFPI. When ESe is increased to >90 V/μm, avalanche multiplication occurs. The avalanche gain ranges between 1-800 depending on ESe and the thickness of the a-Se layer. The avalanche a-Se photoconductor is referred to as High-gain Avalanche Rushing amorphous Photoconductor. The feasibility of two detector configurations based on avalanche gain, each using a different image readout method, are under investigation. Their advantages are compared to other AMPFI technologies for digital radiography and fluoroscopy.

  17. A High-Resolution S-band Down-Converting Digital Phase Detector for SASE FEL Use

    CERN Document Server

    Grelick, A E

    2004-01-01

    Each of the rf phase detectors in the Advanced Photon Source linac consists of a module that down converts from S-band to 20 MHz followed by an analog I/Q detector. Phase is calculated from one digitized sample per pulse each of I and Q. The resulting data has excellent long-term stability but is noisy enough so that a number of samples must be averaged to get a usable reading. The more recent requirement to support a SASE FEL has presented the need to accurately resolve the relative phase of a single pulse. Replacing analog detection with digital sampling and replacing internal intermediate frequency reference oscillators with a lower noise external oscillator were used to control the two largest components of noise. The implementation of a central, ultralow noise reference oscillator and a distribution system capable of maintaining the low phase noise is described, together with the results obtained to date. The principal remaining technical issue is determining the processing power required as a function o...

  18. Test of digital neutron–gamma discrimination with four different photomultiplier tubes for the NEutron Detector Array (NEDA)

    Energy Technology Data Exchange (ETDEWEB)

    Luo, X.L., E-mail: luo.xiaoliang@physics.uu.se [Department of Instrument Science and Technology, College of Mechatronics and Automation, National University of Defense Technology, Changsha (China); Department of Physics and Astronomy, Uppsala University, SE-75120 Uppsala (Sweden); Modamio, V. [INFN, Laboratori Nazionali di Legnaro, I-35020 Legnaro, Padova (Italy); Nyberg, J. [Department of Physics and Astronomy, Uppsala University, SE-75120 Uppsala (Sweden); Valiente-Dobón, J.J. [INFN, Laboratori Nazionali di Legnaro, I-35020 Legnaro, Padova (Italy); Nishada, Q. [Department of Physics and Astronomy, Uppsala University, SE-75120 Uppsala (Sweden); Angelis, G. de [INFN, Laboratori Nazionali di Legnaro, I-35020 Legnaro, Padova (Italy); Agramunt, J. [IFIC-CSIC, University of Valencia, Valencia (Spain); Egea, F.J. [IFIC-CSIC, University of Valencia, Valencia (Spain); Faculty of Engineering and Natural Sciences, Istanbul Sabahattin Zaim University, Istanbul (Turkey); Erduran, M.N.; Ertürk, S. [Nigde Universitesi, Fen-Edebiyat Falkültesi, Fizik Bölümü, Nigde (Turkey); France, G. de [GANIL, CEA/DSAM and CNRS/IN2P3, Bd Henri Becquerel, BP 55027, F-14076 Caen Cedex 05 (France); Gadea, A. [IFIC-CSIC, University of Valencia, Valencia (Spain); González, V. [Department of Electronic Engineering, University of Valencia, E-46071 Valencia (Spain); Hüyük, T. [IFIC-CSIC, University of Valencia, Valencia (Spain); Jaworski, G. [Faculty of Physics, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warszawa (Poland); Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5A, 02-093 Warszawa (Poland); Moszyński, M. [Heavy Ion Laboratory, University of Warsaw, ul. Pasteura 5A, 02-093 Warszawa (Poland); National Centre for Nuclear Research, A. Soltana 7, PL 05-400 Otwock-Swierk (Poland); and others

    2014-12-11

    A comparative study of the neutron–γ discrimination performance of a liquid scintillator detector BC501A coupled to four different 5 in. photomultiplier tubes (ET9390kb, R11833-100, XP4512 and R4144) was carried out. Both the Charge Comparison method and the Integrated Rise-Time method were implemented digitally to discriminate between neutrons and γ rays emitted by a {sup 252}Cf source. In both methods, the neutron–γ discrimination capabilities of the four photomultiplier tubes were quantitatively compared by evaluating their figure-of-merit values at different energy regions between 50 keVee and 1000 keVee. Additionally, the results were further verified qualitatively using time-of-flight to distinguish γ rays and neutrons. The results consistently show that photomultiplier tubes R11833-100 and ET9390kb generally perform best regarding neutron–γ discrimination with only slight differences in figure-of-merit values. This superiority can be explained by their relatively higher photoelectron yield, which indicates that a scintillator detector coupled to a photomultiplier tube with higher photoelectron yield tends to result in better neutron–γ discrimination performance. The results of this work will provide reference for the choice of photomultiplier tubes for future neutron detector arrays like NEDA.

  19. Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

    Energy Technology Data Exchange (ETDEWEB)

    Campello, Abdrea Fagundes; Goncalves, Lucio Souza; Marques, Fabio vidal [Faculty of Dentistry, Estacio de Sa University, Rio de Janeiro (Brazil); Guedes, Fabio Ribeiro [Faculty of Dentistry, Federal University of Rio de Janeiro, Rio de Janeiro (Brazil)

    2017-03-15

    The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using no.1/2, no.2, no.4, and no.6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chi-square test. The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions (P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy.

  20. Cone-beam computed tomography versus digital periapical radiography in the detection of artificially created periapical lesions: A pilot study of the diagnostic accuracy of endodontists using both techniques

    Science.gov (United States)

    Campello, Andrea Fagundes; Gonçalves, Lucio Souza; Guedes, Fábio Ribeiro

    2017-01-01

    Purpose The aim of this study was to compare the diagnostic accuracy of previously trained endodontists in the detection of artificially created periapical lesions using cone-beam computed tomography (CBCT) and digital periapical radiography (DPR). Materials and Methods An ex vivo model using dry skulls was used, in which simulated apical lesions were created and then progressively enlarged using #1/2, #2, #4, and #6 round burs. A total of 11 teeth were included in the study, and 110 images were obtained with CBCT and with an intraoral digital periapical radiographic sensor (Instrumentarium dental, Tuusula, Finland) initially and after each bur was used. Specificity and sensitivity were calculated. All images were evaluated by 10 previously trained, certified endodontists. Agreement was calculated using the kappa coefficient. The accuracy of each method in detecting apical lesions was calculated using the chi-square test. Results The kappa coefficient between examiners showed low agreement (range, 0.17-0.64). No statistical difference was found between CBCT and DPR in teeth without apical lesions (P=.15). The accuracy for CBCT was significantly higher than for DPR in all corresponding simulated lesions (P<.001). The correct diagnostic rate for CBCT ranged between 56.9% and 73.6%. The greatest difference between CBCT and DPR was seen in the maxillary teeth (CBCT, 71.4%; DPR, 28.6%; P<.01) and multi-rooted teeth (CBCT, 83.3%; DPR, 33.3%; P<.01). Conclusion CBCT allowed higher accuracy than DPR in detecting simulated lesions for all simulated lesions tested. Endodontists need to be properly trained in interpreting CBCT scans to achieve higher diagnostic accuracy. PMID:28361026

  1. Standard guide for computed radiography

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide provides general tutorial information regarding the fundamental and physical principles of computed radiography (CR), definitions and terminology required to understand the basic CR process. An introduction to some of the limitations that are typically encountered during the establishment of techniques and basic image processing methods are also provided. This guide does not provide specific techniques or acceptance criteria for specific end-user inspection applications. Information presented within this guide may be useful in conjunction with those standards of 1.2. 1.2 CR techniques for general inspection applications may be found in Practice E2033. Technical qualification attributes for CR systems may be found in Practice E2445. Criteria for classification of CR system technical performance levels may be found in Practice E2446. Reference Images Standards E2422, E2660, and E2669 contain digital reference acceptance illustrations. 1.3 The values stated in SI units are to be regarded as the st...

  2. An evaluation of semiconductor and ionization chamber detectors for diagnostic x-ray dosimetry measurements.

    Science.gov (United States)

    Martin, C J

    2007-08-07

    Dosemeters for performance testing of x-ray equipment may utilize semiconductor technology or ionization chambers (ICs). Semiconductor dosemeters incorporate several elements into the detectors from which compensation for variations in response with photon energy is derived. The design of the detectors influences their response with angle and this is different from that of ICs. The responses of semiconductor detectors (SDs) and ICs to x-ray beams with a variety of radiation qualities have been measured in order to assess differences in response. Measurements have been made with experimental arrangements simulating use of the detectors in performance testing of digital radiography and fluoroscopy equipment. Results show that differences in photon energy responses between the detectors are small, but because ICs are sensitive to radiation incident from all angles, they record more scattered radiation than SDs. Implications of differences in detector responses are discussed and recommendations made about their use. SDs are more appropriate for measurements of image receptor doses and are recommended for setting up automatic exposure control devices for digital radiography. ICs are suitable for assessment of patient entrance surface dose rate measurements. Correction factors that could be applied to allow comparisons between measurements with different dosemeters are proposed.

  3. Power pulsing scheme for analog and digital electronics of the vertex detectors at CLIC

    CERN Document Server

    Blanchot, Georges

    2015-01-01

    The precision requirements of the vertex detector at CLIC impose strong limitations on the mass of such a detector (< 0.2% of a radiation length, Xo, per layer). To achieve such a low material budget, ultra-thin hybrid pixel detectors are foreseen, while the mass for cooling and services will be reduced by implementing a power pulsing scheme that takes advantage of the low duty cycle of the accelerator. The principal aim is to achieve significant power reduction without compromising the power integrity supplied to the front-end electronics. This report summarises the study of a power pulsing scheme to power the vertex barrel electronics of the future CLIC experiment. Its main goal is to describe in more detail what has been already presented in TWEPP conferences and other presentations. The report can therefore serve as an operator manual for future use and development of the system

  4. Silicon microstrip detectors for digital mammography - evaluation and spatial resolution study

    CERN Document Server

    Mali, T; Mikuz, M

    2001-01-01

    Silicon microstrip detectors were used to build an experimental X-ray imaging setup. The detectors were used in an 'edge-on' geometry, with the photons hitting the detector from the side. Efficiencies up to 90% at 20 keV photon energy could be achieved. The system was tested using a standard mammographic phantom. Images of modeled microcalcifications with various diameters down to 200 mu m and images of modeled tumors were made. Spatial resolution of the system was studied on an X-ray test pattern with frequency of line-pairs between 1 and 10l p/mm. An appropriate scanning step combined with knowledge of the system's line spread function was used to deconvolve the measured image and increase the spatial resolution. In this way the effective pixel size was reduced as much as for a factor of approx 3.

  5. Energy measurement and fragment identification using digital signals from partially depleted Si detectors

    CERN Document Server

    Pasquali, G; Neindre, N Le; Ademard, G; Barlini, S; Bini, M; Bonnet, E; Borderie, B; Bougault, R; Bruno, M; Casini, G; Chbihi, A; Cinausero, M; Duenas, J A; Edelbruck, P; Frankland, J D; Gramegna, F; Gruyer, D; Kordyasz, A; Kozik, T; Lopez, O; Marchi, T; Morelli, L; Olmi, A; Ordine, A; Parlog, M; Piantelli, S; Poggi, G; Rivet, M F; Rosato, E; Salomon, F; Spadaccini, G; Stefanini, A A; Valdre, S; Vient, E; Twarog, T; Alba, R; Maiolino, C; Santonocito, D

    2014-01-01

    A study of identification properties of a Si-Si DE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a depleted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the DE-E technique or Pulse Shape Analysis (PSA). Both detectors are reverse mounted: particles enter from the low field side, to enhance the PSA performance. The achieved charge and mass resolution has been quantitatively expressed using a Figure of Merit (FoM). Charge collection efficiency has been evaluated and the possibility of energy calibration corrections has been considered. We find that the DE-E performance is not affected by incomplete depletion even when only 60% of the wafer is depleted. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds are higher tha...

  6. Radiography at CERN

    CERN Document Server

    HSE Unit

    2014-01-01

    What is industrial radiography? It is a non-destructive method with a wide variety of applications, such as inspecting the quality of a weld. It uses high-energy radioactive sources or an X-ray generator.   Is this inspection technique used at CERN? Yes, it is widely used at CERN by the EN-MME Group, which outsources the work to one or more companies, depending on the workload. Is it possible to carry out radiography anywhere at CERN? Yes, it is possible to carry out radiography in any building/accelerator/experiment area at CERN (including in areas which are not normally subject to radiological hazards). When is radiography carried out? It normally takes place outside of working hours (7 p.m. to 6 a.m.). How will I know if radiography is taking place in my building? If this activity is planned in a CERN building, notices will be affixed to all of its main entrance doors at least 24 hours in advance. What are the risks? There is a risk of exposure to very high levels of radiation, dep...

  7. A multi-detector, digitizer based neutron depth profiling device for characterizing thin film materials

    Energy Technology Data Exchange (ETDEWEB)

    Mulligan, P. L.; Cao, L. R.; Turkoglu, D. [Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, Ohio State University, Columbus, Ohio 43210 (United States)

    2012-07-15

    Neutron depth profiling (NDP) is a mature, nondestructive technique used to characterize the concentration of certain light isotopes in a material as a function of depth by measuring the residual energy of charged particles in neutron induced reactions. Historically, NDP has been performed using a single detector, resulting in low intrinsic detection efficiency, and limiting the technique largely to high flux research reactors. In this work, we describe a new NDP instrument design with higher detection efficiency by way of spectrum summing across multiple detectors. Such a design is capable of acquiring a statistically significant charged particle spectrum at facilities limited in neutron flux and operation time.

  8. Performance evaluation of a sub-millimeter spatial resolution PET detector module using a digital silicon photomultiplier coupled LGSO array

    Science.gov (United States)

    Leem, Hyun Tae; Choi, Yong; Kim, Kyu Bom; Lee, Sangwon; Yamamoto, Seiichi; Yeom, Jung-Yeol

    2017-02-01

    In positron emission tomography (PET) for breast, brain and small animal imaging, the spatial resolution of a PET detector is crucial to obtain high quality PET images. In this study, a PET detector for sub-millimeter spatial resolution imaging purpose was assembled using 4×4 pixels of a digital silicon photomultiplier (dSiPM, DPC-3200-22-44, Philips) coupled with a 15×15 LGSO array with BaSO4 reflector, and a 1 mm thick acrylic light guide for light distribution between the dSiPM pixels. The active area of each dSiPM pixel was 3.2×3.9 mm2 and the size of each LGSO scintillator element was 0.7×0.7×6 mm3. In this paper, we experimentally demonstrated the performance of the PET detector by measuring the energy resolution, 2D flood map, peak to valley (P/V) ratio, and coincidence resolving time (CRT). All measurements were performed at a temperature of 10±1 ℃. The average energy resolution was 15.6% (without correcting for saturation effects) at 511 keV and the best CRT was 242±5 ps. The 2D flood map obtained with an energy window of 400-600 keV demonstrated clear identification of all pixels, and the average P/V ratio of the X- and Y-directions were 7.31 and 7.81, respectively. This study demonstrated that the PET detector could be suitable for application in high resolution PET while achieving good timing resolution.

  9. Feline dental radiography and radiology: A primer.

    Science.gov (United States)

    Niemiec, Brook A

    2014-11-01

    Information crucial to the diagnosis and treatment of feline oral diseases can be ascertained using dental radiography and the inclusion of this technology has been shown to be the best way to improve a dental practice. Becoming familar with the techniques required for dental radiology and radiography can, therefore, be greatly beneficial. Novices to dental radiography may need some time to adjust and become comfortable with the techniques. If using dental radiographic film, the generally recommended 'E' or 'F' speeds may be frustrating at first, due to their more specific exposure and image development requirements. Although interpreting dental radiographs is similar to interpreting a standard bony radiograph, there are pathologic states that are unique to the oral cavity and several normal anatomic structures that may mimic pathologic changes. Determining which teeth have been imaged also requires a firm knowledge of oral anatomy as well as the architecture of dental films/digital systems. This article draws on a range of dental radiography and radiology resources, and the benefit of the author's own experience, to review the basics of taking and interpreting intraoral dental radiographs. A simplified method for positioning the tubehead is explained and classic examples of some common oral pathologies are provided. © ISFM and AAFP 2014.

  10. Evaluation of injuries of the upper cervical spine in a postmortem study with digital radiography, CT and MRI; Evaluation experimentell erzeugter Verletzungen der oberen Halswirbelsaeule mit digitaler Roentgentechnik, Computertomographie und Magnetresonanztomographie

    Energy Technology Data Exchange (ETDEWEB)

    Obenauer, S.; Herold, T.; Fischer, U.; Grabbe, E. [Goettingen Univ. (Germany). Abt. fuer Roentgendiagnostik; Fadjasch, G.; Saternus, K.S. [Goettingen Univ. (Germany). Abt. fuer Rechtsmedizin; Koebke, J. [Koeln Univ. (Germany). Anatomisches Inst.

    1999-12-01

    Purpose: To compare digital X-ray, CT, and MRI in the evaluation of ligamentous and osseous lesions in upper cervical spine specimens after artificial craniocervical injury with the findings of macroscopic preparation. Materials and Methods: A rotation trauma of defined severity was applied to 19 human corpses. After dissection of the neck specimens, digital X-ray (DIMA Soft P41, Feinfocus), conventional and helical CT (CTi, High Speed, GE, collimation 1 mm; pitch 1.0), and MRI were performed from the skull base to C3. The findings were correlated with the macroscopic results of preparation. MR (Magnetom Vision, Siemens) imaging was obtained with a 1.5 T system using 2D- and 3D-sequences. Results: Preparation revealed 6 fractures of the vertebral bodies, 5 fractures of the dens axis, 1 fracture of the arcus anterior of the atlas, 4 osseous flakes at the occipital condylus, and 6 lesions of the alar ligaments. Digital radiography showed all fractures and 4 osseous flakes at the occipital condylus. With conventional and helical CT, all fractures and all ruptured alar ligaments could be detected. 2D MRI depicted 9 of the fractures and 3D MRI showed fractures. With 2D MRI, 2 of the 4 osseous flakes at the condylus could be detected and with 3D MRI one occipital condylus fracture could be depicted. Ligamentous injuries were visualized by 2D MRI in 2 of 6 cases and by 3 D MRI inone case. Conclusions: In post-mortem studies, CT was superior to MRI in the visualization of osseous and ligamentous injuries after trauma of the upper cervical spine. However, these results are not transferable to patients with rotation injury in general. (orig.) [German] Ziel: Vergleich verschiedener Techniken (digitale Roentgentechnik, Computertomographie, Magnetresonanztomographie) in der Detektion von ligamentaeren und ossaeren Laesionen der oberen Halswirbelsaeule nach definiertem Trauma sowie Korrelation mit den experimentellen Praeparateergebnissen. Material und Methoden: 19 menschliche

  11. Application of Manual Stitching Technique for Digital Radiography in Total Knee Arthroplasty%DR图像手动拼接技术在全膝关节置换术中的应用

    Institute of Scientific and Technical Information of China (English)

    徐亮; 覃涛

    2014-01-01

    Objective To obtain panorama X-ray images of the lower extremity with a simple method,eliminate the mosai-cing error,and apply this manual stitching technique for digital radiography to the measurement of the force line in total knee arthroplasty.Methods The track of X-ray tube was preset,and Dicom format data were collected by using digital X-ray ima-ging.Then,the data were imported to photoshop CS4 for manual image registration and image fusion.The reliability of the film was tested by comparing the vertical length of the body symbols proj ection in the coronal plane with that on the panorama X-ray (AutoCAD 2010)images.Moreover,the hip-knee-ankle angle was compared before and after operation.Results The matching sample t-test showed there were no significant differences in the length(4 groups of data)between the greater trochanter femur and the fibular head,and between the fibular head and the lateral malleolus between before and after operation(P>0.05 for all) .The hip-knee-ankles angle was much greater after operation than that before operation.Conclusion This manual stitching technique for digital radiography can produce seamless and precise panorama X-ray images,which can be used to reflect the length and angle of the lower extremity before and after operation.%目的:介绍利用简易手段获得下肢全景 X 线片的方法及消除拼接误差的处理,并用于全膝关节置换术(TKA)中的力线测量。方法预先设定需要 X线球管曝光轨迹,使用 DR X线机采集 Dicom 格式图像数据,将图像数据导入Photoshop CS4中进行手动配准及图像融合。最后比较患者体表标志连线在冠状面上的投影之间的垂直长度和全长片在 AutoCAD 2010上的垂直长度。并对患者术前、术后髋-膝-踝角(hip-knee-ankle angle,HKA)进行比较。结果对4组术前、术后大转子至腓骨头,腓骨头至外踝长度数据采用配对样本t检验进行比较,差异无统计学意义(均P>0.05)。术后组 HKA

  12. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... the limitations of Bone X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) ... diagnosis and disease management. top of page How is the procedure performed? The technologist, an individual specially ...

  13. Implementation of digital multiplexing for high resolution X-ray detector arrays.

    Science.gov (United States)

    Sharma, P; Swetadri Vasan, S N; Titus, A H; Cartwright, A N; Bednarek, D R; Rudin, S

    2012-01-01

    We describe and demonstrate for the first time the use of the novel Multiple Module Multiplexer (MMMIC) for a 2×2 array of new electron multiplying charge coupled device (EMCCD) based x-ray detectors. It is highly desirable for x-ray imaging systems to have larger fields of view (FOV) extensible in two directions yet to still be capable of doing high resolution imaging over regions-of-interest (ROI). The MMMIC achieves these goals by acquiring and multiplexing data from an array of imaging modules thereby enabling a larger FOV, and at the same time allowing high resolution ROI imaging through selection of a subset of modules in the array. MMMIC also supports different binning modes. This paper describes how a specific two stage configuration connecting three identical MMMICs is used to acquire and multiplex data from a 2×2 array of EMCCD based detectors. The first stage contains two MMMICs wherein each MMMIC is getting data from two EMCCD detectors. The multiplexed data from these MMMICs is then forwarded to the second stage MMMIC in the similar fashion. The second stage that has only one MMMIC gives the final 12 bit multiplexed data from four modules. This data is then sent over a high speed Camera Link interface to the image processing computer. X-ray images taken through the 2×2 array of EMCCD based detectors using this two stage configuration of MMMICs are shown successfully demonstrating the concept.

  14. Digital X-ray imaging using silicon microstrip detectors: a design study

    Science.gov (United States)

    Speller, R. D.; Royle, G. J.; Triantis, F. A.; Manthos, N.; Van der Stelt, P. F.; di Valentin, M.

    2001-01-01

    This paper considers the basic design parameters for using silicon microstrip detectors for 2-D medical imaging. In particular, mammographic and dental imaging are considered. Monte Carlo modeling techniques have been used to investigate detector efficiency, strip pitch, image quality, imaging geometry and signal processing requirements. Different phantoms are used for each part of the study. It is shown that signal processing times are a major factor in the operation of a clinical detector system if ambiguities are to be avoided in a double-sided strip detector. However, the use of the models allows conclusions to be made that alleviate the timing requirements. It has been shown that using a strip structure of 50-100 μm provides appropriate image resolution and image quality can be maintained with pixel counts of 50-100 in both dental and mammographic work. Under these conditions current front-end electronics designs can provide the signal processing times with an acceptably small number of multihit events (<5%).

  15. Energy measurement and fragment identification using digital signals from partially depleted Si detectors

    Energy Technology Data Exchange (ETDEWEB)

    Pasquali, G.; Pastore, G.; Barlini, S.; Bini, M.; Poggi, G.; Stefanini, A.A.; Valdre, S. [Universita di Firenze, Dipartimento di Fisica, Sesto Fiorentino (Italy); INFN, Sezione di Firenze, Sesto Fiorentino (Italy); Le Neindre, N.; Bougault, R.; Lopez, O.; Vient, E. [ENSICAEN et Universite de Caen, LPC, IN2P3-CNRS, Caen-Cedex (France); Ademard, G.; Borderie, B.; Edelbruck, P.; Rivet, M.F.; Salomon, F. [Universite Paris-Sud 11, Institut de Physique Nucleaire, CNRS/IN2P3, Orsay cedex (France); Bonnet, E.; Chbihi, A.; Frankland, J.D.; Gruyer, D. [CEA/DSM-CNRS/IN2P3, GANIL, B.P. 5027, Caen cedex (France); Casini, G.; Olmi, A.; Piantelli, S. [INFN, Sezione di Firenze, Sesto Fiorentino (Italy); Cinausero, M.; Gramegna, F.; Marchi, T. [INFN-LNL Legnaro, Legnaro (Padova) (Italy); Duenas, J.A. [FCCEE Universidad de Huelva, Departamento de Fisica Aplicada, Huelva (Spain); Kordyasz, A. [University of Warsaw, Heavy Ion Laboratory, Warsaw (Poland); Kozik, T.; Twarog, T. [Institute of Nuclear Physics IFJ-PAN, Jagiellonian University, Krakow (Poland); Morelli, L. [INFN, Bologna (Italy); Universita di Bologna, Bologna (Italy); Ordine, A. [INFN, Sezione di Napoli, Napoli (Italy); Parlog, M. [ENSICAEN et Universite de Caen, LPC, IN2P3-CNRS, Caen-Cedex (France); ' ' Horia Hulubei' ' National Institute of Physics and Nuclear Engineering, Bucharest (Romania); Rosato, E.; Spadaccini, G. [INFN, Sezione di Napoli, Napoli (Italy); Universita di Napoli ' ' Federico II' ' , Dipartimento di Fisica, Napoli (Italy); Alba, R.; Maiolino, C.; Santonocito, D. [INFN-LNS Catania, Catania (Italy); Collaboration: FAZIA Collaboration

    2014-05-15

    A study of identification properties of a Si-Si ΔE-E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a depleted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the ΔE-E technique or the Pulse Shape Analysis (PSA). Both detectors are reverse mounted: particles enter from the low field side, to enhance the PSA performance. The achieved charge and mass resolution has been quantitatively expressed using a Figure of Merit (FoM). Charge collection efficiency has been evaluated and the possibility of energy calibration corrections has been considered. We find that the ΔE-E performance is not affected by incomplete depletion even when only 60% of the wafer is depleted. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds are higher than at full depletion. Good isotopic identification via PSA has been obtained from a partially depleted detector, whose doping uniformity is not good enough for isotopic identification at full depletion. (orig.)

  16. Energy measurement and fragment identification using digital signals from partially depleted Si detectors

    Science.gov (United States)

    Pasquali, G.; Pastore, G.; Le Neindre, N.; Ademard, G.; Barlini, S.; Bini, M.; Bonnet, E.; Borderie, B.; Bougault, R.; Casini, G.; Chbihi, A.; Cinausero, M.; Dueñas, J. A.; Edelbruck, P.; Frankland, J. D.; Gramegna, F.; Gruyer, D.; Kordyasz, A.; Kozik, T.; Lopez, O.; Marchi, T.; Morelli, L.; Olmi, A.; Ordine, A.; Pârlog, M.; Piantelli, S.; Poggi, G.; Rivet, M. F.; Rosato, E.; Salomon, F.; Spadaccini, G.; Stefanini, A. A.; Valdrè, S.; Vient, E.; Twaróg, T.; Alba, R.; Maiolino, C.; Santonocito, D.

    2014-05-01

    A study of identification properties of a Si-Si ΔE- E telescope exploiting an underdepleted residual-energy detector has been performed. Five different bias voltages have been used, one corresponding to full depletion, the others associated with a depleted layer ranging from 90% to 60% of the detector thickness. Fragment identification has been performed using either the ΔE- E technique or the Pulse Shape Analysis (PSA). Both detectors are reverse mounted: particles enter from the low field side, to enhance the PSA performance. The achieved charge and mass resolution has been quantitatively expressed using a Figure of Merit (FoM). Charge collection efficiency has been evaluated and the possibility of energy calibration corrections has been considered. We find that the ΔE- E performance is not affected by incomplete depletion even when only 60% of the wafer is depleted. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds are higher than at full depletion. Good isotopic identification via PSA has been obtained from a partially depleted detector, whose doping uniformity is not good enough for isotopic identification at full depletion.

  17. Bone X-Ray (Radiography)

    Medline Plus

    Full Text Available ... Resources Professions Site Index A-Z X-ray (Radiography) - Bone Bone x-ray uses a very small ... X-ray (Radiography)? What is Bone X-ray (Radiography)? An x-ray (radiograph) is a noninvasive medical ...

  18. The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography.

    Science.gov (United States)

    Cowen, A R; Davies, A G; Sivananthan, M U

    2008-10-01

    Dynamic, flat-panel, solid-state, x-ray image detectors for use in digital fluoroscopy and fluorography emerged at the turn of the millennium. This new generation of dynamic detectors utilize a thin layer of x-ray absorptive material superimposed upon an electronic active matrix array fabricated in a film of hydrogenated amorphous silicon (a-Si:H). Dynamic solid-state detectors come in two basic designs, the indirect-conversion (x-ray scintillator based) and the direct-conversion (x-ray photoconductor based). This review explains the underlying principles and enabling technologies associated with these detector designs, and evaluates their physical imaging characteristics, comparing their performance against the long established x-ray image intensifier television (TV) system. Solid-state detectors afford a number of physical imaging benefits compared with the latter. These include zero geometrical distortion and vignetting, immunity from blooming at exposure highlights and negligible contrast loss (due to internal scatter). They also exhibit a wider dynamic range and maintain higher spatial resolution when imaging over larger fields of view. The detective quantum efficiency of indirect-conversion, dynamic, solid-state detectors is superior to that of both x-ray image intensifier TV systems and direct-conversion detectors. Dynamic solid-state detectors are playing a burgeoning role in fluoroscopy-guided diagnosis and intervention, leading to the displacement of x-ray image intensifier TV-based systems. Future trends in dynamic, solid-state, digital fluoroscopy detectors are also briefly considered. These include the growth in associated three-dimensional (3D) visualization techniques and potential improvements in dynamic detector design.

  19. 全数字化乳腺平板摄影技术探讨%Research of Examination Technique of Digital Mammography Using Digital Flat Panel Detector System

    Institute of Scientific and Technical Information of China (English)

    许静; 袁彩云; 徐莉

    2011-01-01

    目的:探讨数字化乳腺摄影规范的操作方法,以优化乳腺图像质量,从而提高乳腺病变的检出率和诊断的正确率.方法:回顾性分析4 000例患者的数字化乳腺摄影的图像,对每一个摄影位置的摆位方法进行主观评价,对相应图像质量进行分级,进行相关性总结分析.结果:15 420幅所摄图像中,规范操作获得的Ⅰ级片15 012幅,占97.35%;因患者配合问题、不规范操作、设备引起的图像质量下降等问题导致的Ⅱ级片达376幅,占2.44%:需重新拍摄有32次,占0.21%.结论:在全数字化乳腺摄影中,高质量乳腺片的获得需规范的摄影投照方法、定期的设备质量图像校正.%Objective To research the normative operation method of digital mammography for optimizing image quality, so as to improve the diagnostic accuracy of pathological changes. Methods Four thousand cases of mammography images were analyzed retrospectively. Each radiography operation method was evaluated in image quality classification. The relationship between mammography operation and image quality was analyzed. Results There were 15,012 images classified as class I, which accounted for 97.35% among all 15,420 images, and 376 images(2.44%) were class II, which were caused by patient's bad cooperation, abnormal operation of technician and other causes of equipment problem. Thirty two images (0.21%) needed re-operation of mammography due to severely low image quality. Conclusion For acquisition of high quality of mammography images, normative mammography operation and periodical equipment image quality calibration are essential.[Chinese Medical Equipment Journal.2011,32( 12): 112-113

  20. Thorium-uranium fission radiography

    Science.gov (United States)

    Haines, E. L.; Weiss, J. R.; Burnett, D. S.; Woolum, D. S.

    1976-01-01

    Results are described for studies designed to develop routine methods for in-situ measurement of the abundance of Th and U on a microscale in heterogeneous samples, especially rocks, using the secondary high-energy neutron flux developed when the 650 MeV proton beam of an accelerator is stopped in a 42 x 42 cm diam Cu cylinder. Irradiations were performed at three different locations in a rabbit tube in the beam stop area, and thick metal foils of Bi, Th, and natural U as well as polished silicate glasses of known U and Th contents were used as targets and were placed in contact with mica which served as a fission track detector. In many cases both bare and Cd-covered detectors were exposed. The exposed mica samples were etched in 48% HF and the fission tracks counted by conventional transmitted light microscopy. Relative fission cross sections are examined, along with absolute Th track production rates, interaction tracks, and a comparison of measured and calculated fission rates. The practicality of fast neutron radiography revealed by experiments to data is discussed primarily for Th/U measurements, and mixtures of other fissionable nuclei are briefly considered.

  1. Chemiluminescence detector based on a single planar transparent digital microfluidic device.

    Science.gov (United States)

    Zeng, Xiangyu; Zhang, Kaidi; Pan, Jian; Chen, Guoping; Liu, Ai-Qun; Fan, Shih-Kang; Zhou, Jia

    2013-07-21

    We report on a compact and portable prototype of chemiluminescence detector based on a single planar single polar transparent electrowetting-on-dielectrics (EWOD) device. The coupling ground model was proposed to build the EWOD device, which could be driven under a single polar voltage. Such a design not only simplified the chip construction and control circuit, but also had the potential for the ball-like droplet to focus the fluorescence and enhance the detection sensitivity. Simulations and experiments both confirmed that the greater the contact angle, the stronger the detected optical signal, and thus the higher the sensitivity. The sensitivity of the prototype detector to H2O2 was 5.45 mV (mmol L(-1))(-1) and the detection limit was 0.01 mmol L(-1) when the contact angle of the EWOD surface was 120°. To further increase the sensitivity and decrease the detection limit, the contact angle of the EWOD device could be increased and the dark current of the photomultiplier decreased. The prototype shows potential applications as highly sensitive, cost effective and portable immuno-detectors, especially as a blood glucose monitor.

  2. A 12GHz 210fs 6mW digital PLL with sub-sampling binary phase detector and voltage-time modulated DCO

    NARCIS (Netherlands)

    Ru, Z.; Geraedts, P.F.J.; Klumperink, Eric A.M.; He, X.; Nauta, Bram

    2013-01-01

    An integer-N digital PLL architecture is presented that simplifies the critical phase path using a sub-sampling binary (bang-bang) phase detector. Two power-efficient techniques are presented that can reduce DCO frequency tuning step by voltage-domain and time-domain (pulse-width) modulating the DCO

  3. A 12GHz 210fs 6mW digital PLL with sub-sampling binary phase detector and voltage-time modulated DCO

    NARCIS (Netherlands)

    Ru, Z.; Geraedts, P.; Klumperink, E.; He, X.; Nauta, B.

    2013-01-01

    An integer-N digital PLL architecture is presented that simplifies the critical phase path using a sub-sampling binary (bang-bang) phase detector. Two power-efficient techniques are presented that can reduce DCO frequency tuning step by voltage-domain and time-domain (pulse-width) modulating the DCO

  4. Full breast digital mammography with an amorphous silicon-based flat panel detector: physical characteristics of a clinical prototype.

    Science.gov (United States)

    Vedantham, S; Karellas, A; Suryanarayanan, S; Albagli, D; Han, S; Tkaczyk, E J; Landberg, C E; Opsahl-Ong, B; Granfors, P R; Levis, I; D'Orsi, C J; Hendrick, R E

    2000-03-01

    The physical characteristics of a clinical prototype amorphous silicon-based flat panel imager for full-breast digital mammography have been investigated. The imager employs a thin thallium doped CsI scintillator on an amorphous silicon matrix of detector elements with a pixel pitch of 100 microm. Objective criteria such as modulation transfer function (MTF), noise power spectrum, detective quantum efficiency (DQE), and noise equivalent quanta were employed for this evaluation. The presampling MTF was found to be 0.73, 0.42, and 0.28 at 2, 4, and 5 cycles/mm, respectively. The measured DQE of the current prototype utilizing a 28 kVp, Mo-Mo spectrum beam hardened with 4.5 cm Lucite is approximately 55% at close to zero spatial frequency at an exposure of 32.8 mR, and decreases to approximately 40% at a low exposure of 1.3 mR. Detector element nonuniformity and electronic gain variations were not significant after appropriate calibration and software corrections. The response of the imager was linear and did not exhibit signal saturation under tested exposure conditions.

  5. Monolithic single-photon detectors and time-to-digital converters for picoseconds time-of-flight ranging

    Science.gov (United States)

    Markovic, Bojan; Tisa, Simone; Tosi, Alberto; Zappa, Franco

    2011-03-01

    We present a novel "smart-pixel" able to measure and record in-pixel the time delay (photon timing) between a START (e.g. given by laser excitation, cell stimulus, or LIDAR flash) and a STOP (e.g. arrival of the first returning photon from the fluorescence decay signal or back reflection from an object). Such smart-pixel relies of a SPAD detector and a Timeto- Digital Converter monolithically designed and manufactured in the same chip. Many pixels can be laid out in a rows by columns architecture, to give birth to expandable 2D imaging arrays for picoseconds-level single-photon timing applications. Distance measurements, by means of direct TOF detection (used in LIDAR systems) provided by each pixel, can open the way to the fabrication of single-chip 3D ranging arrays for scene reconstruction and intelligent object recognition. We report on the design and characterization of prototype circuits, fabricated in a 0.35 μm standard CMOS technology containing complete conversion channels, "smart-pixel" and ancillary electronics with 20 μm active area diameter SPAD detector and related quenching circuitry. With a 100 MHz reference clock, the TDC provides timeresolution of 10 ps, dynamic range of 160 ns and very high conversion linearity.

  6. NOTE: First images of a digital autoradiography system based on a Medipix2 hybrid silicon pixel detector

    Science.gov (United States)

    Mettivier, Giovanni; Montesi, Maria Cristina; Russo, Paolo

    2003-06-01

    We present the first images of beta autoradiography obtained with the high-resolution hybrid pixel detector consisting of the Medipix2 single photon counting read-out chip bump-bonded to a 300 µm thick silicon pixel detector. This room temperature system has 256 × 256 square pixels of 55 µm pitch (total sensitive area of 14 × 14 mm2), with a double threshold discriminator and a 13-bit counter in each pixel. It is read out via a dedicated electronic interface and control software, also developed in the framework of the European Medipix2 Collaboration. Digital beta autoradiograms of 14C microscale standard strips (containing separate bands of increasing specific activity in the range 0.0038-32.9 kBq g-1) indicate system linearity down to a total background noise of 1.8 × 10-3 counts mm-2 s-1. The minimum detectable activity is estimated to be 0.012 Bq for 36 000 s exposure and 0.023 Bq for 10 800 s exposure. The measured minimum detection threshold is less than 1600 electrons (equivalent to about 6 keV Si). This real-time system for beta autoradiography offers lower pixel pitch and higher sensitive area than the previous Medipix1-based system. It has a 14C sensitivity better than that of micro channel plate based systems, which, however, shows higher spatial resolution and sensitive area.

  7. MRI versus radiography of acromioclavicular joint dislocation.

    Science.gov (United States)

    Nemec, Ursula; Oberleitner, Gerhard; Nemec, Stefan F; Gruber, Michael; Weber, Michael; Czerny, Christian; Krestan, Christian R

    2011-10-01

    Acromioclavicular joint injuries are usually diagnosed by clinical and radiographic assessment with the Rockwood classification, which is crucial for treatment planning. In view of the implementation of MRI for visualization of the acromioclavicular joint, the purpose of this study was to describe the MRI findings of acromioclavicular joint dislocation in comparison with the radiographic findings. Forty-four patients with suspected unilateral acromioclavicular joint dislocation after acute trauma were enrolled in this prospective study. All patients underwent digital radiography and 1-T MRI with a surface phased-array coil. MRI included coronal proton density-weighted turbo spin-echo and coronal 3D T1-weighted fast field-echo water-selective sequences. The Rockwood classification was used to assess acromioclavicular joint injuries at radiography and MRI. An adapted Rockwood classification was used for MRI evaluation of the acromioclavicular joint ligaments. The classifications of acromioclavicular joint dislocations diagnosed with radiography and MRI were compared. Among 44 patients with Rockwood type I-IV injuries on radiographs, classification on radiographs and MR images was concordant in 23 (52.2%) patients. At MRI, the injury was reclassified to a less severe type in 16 (36.4%) patients and to a more severe type in five (11.4%) patients. Compared with the findings according to the original Rockwood system, with the adapted system that included MRI findings, additional ligamentous lesions were found in 11 (25%) patients. In a considerable number of patients, the MRI findings change the Rockwood type determined with radiography. In addition to clinical assessment and radiography, MRI may yield important findings on ligaments that may influence management.

  8. The research of a new digital radiography machine’s image quality control%新装机 DR 图像质量控制方法的建立

    Institute of Scientific and Technical Information of China (English)

    唐之钊; 彭松

    2015-01-01

    Objective Obtain high qualified picture through analyzing the quality control method of the initial image of a new digital radiography machine. Methods Choose the six common-used part of ody, anteroposterior chest, cervical anteropos-terior, lumbar spine, anteroposterior abdominal, anteroposterior pelvis and foot anteroposterior, and graphed them in appropri-ate condition with the machine. Then send the pictures deal apart by initial-set image parameters(Factory), user-difined image parameters 1(C1) as well as user-defined image parameters 2(C2) to the PACS. A group consist of physicians and mechanics will assess the three picture films of each part blindly, which are printed by the laser camera. The highest votes of the three in each part will be the default parameters afterwards. Results It turns out that the best parameters for the selected of anteroposte-rior chest, cervical ant-eroposterior, lumbar spine,anteroposterior abdominal, anteroposterior pelvis and foot anteropos- -terior is the C1, the C1, the C2, the Factory, the C1 and the C2. Conclusion Choosing the right image parameters for DR machine can help the mechanics to get the quality control method of the initial image of a new digital radiography machine.%目的:探讨新装机数字化 X 线摄影(DR)设备图像初始质量控制方法以期获取满意图像质量。方法:选取胸部正位、颈椎正位、腰椎正位、腹部正位、骨盆正位、足正位6个常用部位采用合适摄片条件照片,获取的图像分别用厂方默认图像处理参数组(Factory)、自定义图像处理参数一组(C1)、自定义图像处理参数二组(C2)处理,将得到的同一部位的三幅图像传到医学影像存档与通讯系统(PACS)中,最后用激光相机打印出胶片由医师及技师组成的评价小组分别对每个部位的三幅图像进行盲评,统计每个部位中得票数最高的照片,将该照片的图像处理参数组合作为今后技

  9. Clinical value of digital radiography in reducing radiation dose in patients with pneumoconiosis%数字化X线摄影在尘肺病患者检查中降低辐射剂量的临床价值

    Institute of Scientific and Technical Information of China (English)

    秦好朴; 孙吉林; 赵欣; 张明; 徐晓

    2016-01-01

    目的:探讨低辐射剂量数字化X线摄影( DR)在尘肺病患者胸部检查中的应用价值。方法对我院接受诊断与治疗的24例尘肺病患者进行了低剂量DR和常规剂量DR检查,并比较两种检查剂量的图片质量。结果常规剂量组和低剂量组所用曝光剂量不同,但是患者在第一前肋间、第二前肋间、第三前肋间、第四前肋间、肺肝重叠区、背景区等6个区域的DR照片密度值比较无明显差异( t =1.54、1.52、1.76、1.98、0.56、1.92, P >0.05)。这表明低剂量DR胸片质量与常规剂量比较无明显差异,可以达到有效诊断的效果。结论在尘肺病患者胸部检查中虽然降低了数字化X线摄影的曝光量,但是对DR胸片质量无明显影响,可以获得与常规剂量胸部数字化X线摄影相同的诊断效果。%Objective To explore the application value of digital radiography with low radiation dose in chest examination on patients with pneumoconiosis .Methods 24 patients with pneumoconiosis , who were accepted the diagnosis and treatment in Xingtai City People's Hospital from January , 2015 to December , 2015 , underwent the examination of low dose DR and convention-al dose DR and , meanwhile , the picture quality obtained by the two methods with different doses was compared in this work .Re-sults The exposure dose in the conventional dose group and low dose group was different .However , the value of DR image den-sity in six zones, i.e., the first intercostal space, the second anterior intercostal space , the third intercostal space, the fourth an-terior intercostal space , the overlapping area of liver and lung , background area of DR had no significant difference ( t =1.54, 1.52, 1.76, 1.98, 0.56, 1.92, P >0.05).These results showed that the picture quality from low dose DR and conventional dose DR was not significant different .Conclusion In the chest examination , while reducing exposure dose of the

  10. 数字化X线摄影术(DR)在肋骨骨折诊断中的应用价值%X digital radiography(DR) in the diagnosis of rib fracture

    Institute of Scientific and Technical Information of China (English)

    谢钊; 沈本涛

    2014-01-01

    Objective to analyze the X digital radiography (DR) in diagnosis of rib fracture in chest trauma;Methods 120 patients with severe chest trauma from 2011 January to 2013 December in our hospital for treatment of patients, chest DR scan, to understand there is no rib fracture;Results 120 cases of thoracic trauma all happened in rib fracture, a total of 191;Conclusion DR can fracture due to chest trauma and early diagnosis of rib, is currently the most effective, the diagnosis of rib fracture in cheap, fast examination method, it has an important clinical value.%目的:探讨数字化X线摄影术(DR)在胸部创伤致肋骨骨折诊断中的应用价值。方法选择2011年1月-2013年12月来我院就诊的较严重的胸部创伤患者120例,行胸部DR检查,以了解有无肋骨骨折存在。结果120例胸部创伤患者中全部发生肋骨骨折,共有191处。结论 DR能够早期诊断因胸部创伤所致的肋骨骨折,是目前诊断肋骨骨折最有效、价廉、快速的检查方法,具有重要的临床实用价值。

  11. 平板DR数字成像技术在焊管行业中的应用%Application of Flat Panel Digital Radiography Imaging Technology in Welded Pipe Industry

    Institute of Scientific and Technical Information of China (English)

    王长安; 余国民; 魏雅博

    2014-01-01

    In this article, it introduced the working principle of digital radiography(DR) imaging technology and its application in welded pipe industry. Compared with the detection effect of traditional X-ray industrial TV from sensitivity detection, image resolution, residual magnetization, radiation dose etc. The result showed that the flat panel DR imaging technology is with some advantages, such as high sensitivity of detection, high efficiency, low labour tension, little doses of radiation and so on. It ensures the weld quality, greatly reduces the accident rate of pipeline, and can replace X-ray industrial TV detecting technology. At present, this technology is widely applied in welded pipe industry.%介绍了DR数字成像技术的工作原理及其在焊管行业检测中的应用。在灵敏度检测、图像分辨率、剩磁影响和辐射剂量等方面与传统的X射线工业电视的检测效果进行了比较分析。结果表明, DR数字成像技术具有检测灵敏度和检测效率较高、劳动强度小、辐射剂量小等优点,保证了焊缝质量,大大降低了管线的事故发生率,可以替代传统X射线工业电视检测技术在焊管行业的应用。

  12. 数字化鼻咽侧位影像在儿童腺样体肥大的诊断中的价值%Value of Direct Digital Radiography Imaging in the Preoperative Diagnosis of Children with Adenoid Hypertrophy

    Institute of Scientific and Technical Information of China (English)

    潘鄂武; 陈军; 罗志宏; 彭宙锋; 汪炜伟; 刘昌盛

    2011-01-01

    目的:探讨直接数字化X线摄影(DR)鼻咽侧位片在儿童腺样体肥大的诊断中的价值.方法:采用鼻咽侧位片腺样体-鼻咽腔(A/N)比率测量值,结合临床症状及纤维鼻咽镜检查儿童腺样体的分度范围(Ⅰ-Ⅳ°)进行影像诊断.结果:112例A/N在0.61-0.89之间的患儿,经保守治疗无效,再经低温等离子射频切割消融术治疗后痊愈出院.结论:鼻咽侧位A/N比值,可作诊断儿童腺样体肥大的客观指标.%Objective; To discuss the value of the lateral direct digital radiography (DR) imaging of nasopharynx in the diagnosis of children with adenoid hypertrophy. Methods: Nasopharynx lateral DR was used to measure the ratio of adenoid to nasopharynx cavity (A/N). Imaging diagnosis was made upon the basis of combining the clinical symptoms and the nasopharyngo-fiberoscope to classify the children's adenoids (grades I ~IV°). Results; A total of 114 cases of adenoid hypertrophy with the ratio of A/N ranging from 0. 61 to 0. 89 were treated by low-temperature plasma radiofrequency ablation after the conventional treatment was not effective. Conclusion: The ratio of A/N might be an objective index in the diagnosis of children's adenoid hypertrophy.

  13. Clinical evaluation of digital angiographic system equipped with the Safire' flat-panel detector of a direct conversion type

    Energy Technology Data Exchange (ETDEWEB)

    Miura, Yoshiaki; Miura, Yusuke; Goto, Keiichi [Shimadzu Corporation, Medical Systems Division, Research and Development, Kyoto (JP)] [and others

    2003-06-01

    This report presents a report on clinical evaluation of our newly developed flat-panel X-ray detector of a direct conversion type, designed to provide images of a resolution higher than, or at least equal to, that ensured by X-ray photographic films, in clinical digital X-ray cinematography. This new detector was named 'Safire' the acronym of 'Shimadzu advanced flat imaging receptor', emphasizing its high technological level, such as the capability to ensure high quality of images. The clinical evaluation of Shimadzu DIGITEX Premier digital angiography system, equipped with this new flat-panel X-ray detector of a direct conversion type, has been started in March, 2003, at the Kokura Memorial Hospital in Kyushu, Japan. (author)

  14. An investigation of the digital discrimination of neutrons and {gamma} rays with organic scintillation detectors using an artificial neural network

    Energy Technology Data Exchange (ETDEWEB)

    Liu, G.; Aspinall, M.D.; Ma, X. [Department of Engineering, Lancaster University, Bailrigg, Lancaster LA1 4YR (United Kingdom); Joyce, M.J. [Department of Engineering, Lancaster University, Bailrigg, Lancaster LA1 4YR (United Kingdom)], E-mail: m.joyce@lancaster.ac.uk

    2009-08-21

    The discrimination of neutron and {gamma}-ray events in an organic scintillator has been investigated by using a method based on an artificial neural network (ANN). Voltage pulses arising from an EJ-301 organic liquid scintillation detector in a mixed radiation field have been recorded with a fast digital sampling oscilloscope. Piled-up events have been disentangled using a pile-up management unit based on a fitting method. Each individual pulse has subsequently been sent to a discrimination unit which discriminates neutron and {gamma}-ray events with a method based on an artificial neural network. This discrimination technique has been verified by the corresponding mixed-field data assessed by time of flight (TOF). It is shown that the characterization of the neutrons and photons achieved by the discrimination method based on the ANN is consistent with that afforded by TOF. This approach enables events that are often as a result of scattering or pile-up to be identified and returned to the data set and affords digital discrimination of mixed radiation fields in a broad range of environments on the basis of training obtained with a single TOF dataset.

  15. Progress on the development of a detector mounted analog and digital readout system for the ATLAS TRT

    CERN Document Server

    Baxter, C; Dressnandt, N; Gay, C; Lundberg, B; Munar, A; Mayers, G; Newcomer, M; Van Berg, R; Williams, H H

    2004-01-01

    The 430,000 element ATLAS Transition Radiation straw tube Tracker (TRT) is divided into a central barrel tracker consisting of 104,000 axially mounted straws and two radially arranged end caps on either side of the barrel with 160,000 straws each. To achieve a track position resolution of 140 mu m, the front end electronics must operate at a low (2fC) threshold with a time marking capability of ~1ns. Two ASICs, the ASDBLR and DTMROC provide the complete pipelined readout chain. Custom designed FBGA packages for the ASICs provide a small enough outline to be detector mounted and the extensive use of low level differential signals make mounting the analog packages on printed circuit boards directly opposite the 40 MHz digital chips feasible. The readout electronics for the barrel occupies a potentially important part of the active tracker volume and an aggressive effort has been made to make it as compact as possible. Utilizing a single board for both analog and digital ASICS a 0.1 cm /sup 3/ per channel volume...

  16. Measurement of the energy spectra of fission fragments using nuclear track detectors and digital image processing

    Energy Technology Data Exchange (ETDEWEB)

    Espinosa, Guillermo; Golzarri, Jose I. [Instituto de Fisica, Universidad Nacional Autonoma de Mexico, A.P. 20-364, Mexico D.F. 01000 (Mexico); Castano, Victor M., E-mail: castano@fata.unam.m [Centro de Fisica Aplicada y Tecnologia Avanzada, Universidad Nacional Autonoma de Mexico, Boulevard Juriquilla 3001, Santiago de Queretaro, Queretaro 76230 (Mexico)

    2010-08-15

    Energy spectra of fission fragments were determined using a Nuclear Track Methodology (NTM) supported by digital image analysis and numerical data processing using a standard personal computer. The analysis of a californium ({sup 252}Cf) spectrum with this approach shows improvement compared with the values reported previously using the standard procedure, in terms of resolution and accuracy. This new method adds full automation to the technical advantages and cost effectiveness of an NTM.

  17. Sixteen-Channel Board ADB-16 with Analog and Digital Outputs for Application with Gas Detectors

    CERN Document Server

    Alexeev, G D; Tokmenin, V V

    2005-01-01

    The description and characteristics of sixteen-channel board ADB-16 with analog and digital outputs are presented. It is built on the basis of IC of eight-channel amplifiers AMPL-8.3 and discriminators DISC-8.3 developed jointly by the Research Institute for Nuclear Problems of Belarussian State University, Minsk, and JINR, Dubna, for the muon system of D0 experiment (FNAL).

  18. A Novel Front-End ASIC With Post Digital Filtering and Calibration for CZT-Based PET Detector

    Energy Technology Data Exchange (ETDEWEB)

    Gao, W.; Yin, J.; Li, C.; Zeng, H.; Gao, D. [Institute of Microelectronics, School of Computer Science and Techonology, Northwestern Polytechnical University, Xi' an (China); Hu, Y. [Institut Pluridiscipline Hubert Curien, CNRS/UDS/IN2P3, Strasbourg (France)

    2015-07-01

    This paper presents a novel front-end electronics based on a front-end ASIC with post digital filtering and calibration dedicated to CZT detectors for PET imaging. A cascade amplifier based on split-leg topology is selected to realize the charge-sensitive amplifier (CSA) for the sake of low noise performances and the simple scheme of the power supplies. The output of the CSA is connected to a variable-gain amplifier to generate the compatible signals for the A/D conversion. A multi-channel single-slope ADC is designed to sample multiple points for the digital filtering and shaping. The digital signal processing algorithms are implemented by a FPGA. To verify the proposed scheme, a front-end readout prototype ASIC is designed and implemented in 0.35 μm CMOS process. In a single readout channel, a CSA, a VGA, a 10-bit ADC and registers are integrated. Two dummy channels, bias circuits, and time controller are also integrated. The die size is 2.0 mm x 2.1 mm. The input range of the ASIC is from 2000 e{sup -} to 100000 e{sup -}, which is suitable for the detection of the X-and gamma ray from 11.2 keV to 550 keV. The linearity of the output voltage is less than 1 %. The gain of the readout channel is 40.2 V/pC. The static power dissipation is about 10 mW/channel. The above tested results show that the electrical performances of the ASIC can well satisfy PET imaging applications. (authors)

  19. The Image Quality of a Digital Chest X-Ray Radiography System: Comparison of Quantitative Image Quality Analysis and Radiologists' Visual Scoring

    Energy Technology Data Exchange (ETDEWEB)

    Nam, Ji Ho [Dept. of Radiology Oncology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of); Chung, Myung Jin [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Park, Darl; Kim, Won Taek; Kim, Yong Ho; Ki, Yong Kan; Kim, DFong Hyun; Lee, Ju Hee; Kim, Dong Won [Dept. of Radiology Oncology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of); Jeon, Ho Sang [Reserach Institue for Convergence of Biomedical Science and Technology, Yongsan Hospital, Pusan National University College of Medicine, Yongsan (Korea, Republic of)

    2011-11-15

    To evaluate the performance of imaging devices, which should be periodically monitored to maintain high quality images to the radiologists. Additionally, this evaluation may prevent patients from radiation over-exposure. The most suitable engineering standard for imaging performance evaluation of digital X-ray thoracic images was determined. IEC 62220-1 standards were used to evaluate the performance of the images. In succession, the visibilities of overall image, pneumothorax, and humerus head in anthropomorphic thoracic phantom images were used to evaluate the image qualities by radiologists. The rank correlation coefficient (p) of visual scoring by radiologists with system spatial resolution is not meaningful (p-value, p = 0.295), but is significant with image noise (p-value, p -0.9267). Finally, the noise equivalent quanta (NEQ) presents a high rank correlation for visual scoring of radiologists (p-value, p = 0.9320). Image quality evaluation of radiologists were mainly affected by imaging noise. Hence, the engineered standard for evaluating image noise is the most important index to effectively monitor the performance of X-ray images. Additionally, the NEQ can be used to evaluate the performance of radiographic systems, because it theoretically corresponds to the synthetic image quality of systems.

  20. A Fully Digital AGC System with 100MHz Bandwidth and 35dB Dynamic Range Power Detectors for DVB-S2 Application

    Science.gov (United States)

    Pu, Younggun; Lee, Kang-Yoon

    This paper presents a fully digital gain control system with a new high bandwidth and wide dynamic range power detector for DVB-S2 application. Because the peak-to-average power ratio (PAPR) of DVB-S2 system is so high and the settling time requirement is so stringent, the conventional closed-loop analog gain control scheme cannot be used. The digital gain control is necessary for the robust gain control and the direct digital interface with the baseband modem. Also, it has several advantages over the analog gain control in terms of the settling time and insensitivity to the process, voltage and temperature variation. In order to have a wide gain range with fine step resolution, a new AGC system is proposed. The system is composed of high-bandwidth digital VGAs, wide dynamic range power detectors with RMS detector, low power SAR type ADC, and a digital gain controller. To reduce the power consumption and chip area, only one SAR type ADC is used, and its input is time-interleaved based on four power detectors. Simulation and measurement results show that the new AGC system converges with gain error less than 0.25dB to the desired level within 10µs. It is implemented in a 0.18µm CMOS process. The measurement results of the proposed IF AGC system exhibit 80-dB gain range with 0.25-dB resolution, 8nV/\\\\!\\\\sqrt{Hz} input referred noise, and 5-dBm IIP3 at 60-mW power consumption. The power detector shows the 35dB dynamic range for 100MHz input.

  1. Study of pipe thickness loss using a neutron radiography method

    Energy Technology Data Exchange (ETDEWEB)

    Mohamed, Abdul Aziz; Wahab, Aliff Amiru Bin [Universiti Tenaga Nasional, Jalan IKRAM-UNITEN, 43000 Kajang, Selangor (Malaysia); Yazid, Hafizal B.; Ahmad, Megat Harun Al Rashid B. Megat; Jamro, Rafhayudi B.; Azman, Azraf B.; Zin, Muhamad Rawi Md; Idris, Faridah Mohamad [Malaysian Nuclear Agency, Bangi, 43000 Kajang, Selangor (Malaysia)

    2014-02-12

    The purpose of this preliminary work is to study for thickness changes in objects using neutron radiography. In doing the project, the technique for the radiography was studied. The experiment was done at NUR-2 facility at TRIGA research reactor in Malaysian Nuclear Agency, Malaysia. Test samples of varying materials were used in this project. The samples were radiographed using direct technique. Radiographic images were recorded using Nitrocellulose film. The films obtained were digitized to processed and analyzed. Digital processing is done on the images using software Isee!. The images were processed to produce better image for analysis. The thickness changes in the image were measured to be compared with real thickness of the objects. From the data collected, percentages difference between measured and real thickness are below than 2%. This is considerably very low variation from original values. Therefore, verifying the neutron radiography technique used in this project.

  2. Development of the digital read-out system for the CERN Alice pixel detector

    CERN Document Server

    Grassi, Tullio

    In order to gain new experimental insight at the TeV energy scale, CERN (Geneva) will build the Large Hadron Collider (LHC), a new collider machine operating at a maximum center-of-mass energy of 14 TeV (in the p+/p+ interactions). The accelerator can operate in a heavy ion collision mode achieving a center-of-mass energy of ~5.5 TeV. The experimental environment at LHC is characterized by a high crossing rate of the particle bunches (one every 25 ns for p+/p+) and high levels of radiation. Therefore stringent requirements are imposed on the performance of detectors at LHC. Such a particle physics environment calls for dedicated hardware/software solutions with specific constraints, such as radiation tolerance, limited amount of material and limited power dissipation. One of the particle physics experiments carried out in LHC is ALICE (A Large Ion Collider Experiment). The ALICE detector will face a very high density of tracks of particles (a multiplicity of 8000 charged particles per unit of rapidity, that i...

  3. Sensor noise in direct digital imaging (the RadioVisioGraphy, Sens-a-Ray, and Visualix/Vixa systems) evaluated by subtraction radiography.

    Science.gov (United States)

    Wenzel, A

    1994-01-01

    The aim of this study was to evaluate sensor noise with the use of the subtraction method in radiographs captured with three direct digital intraoral systems. Ten radiographs were taken of the lower left molar region of a phantom head at each of three exposure times: 0.20 seconds, 0.46 seconds, and 0.60 seconds with the use of the RadioVisioGraphy (Trophy Radiologie, Vincennes, France), Sens-a-Ray (Regam Medical Systems, AB, Sundsvall, Sweden), and Visualix (Gendex, Philips Medical Systems, Inc., Monza, Italy) systems. Neither the x-ray tube nor the phantom were moved between exposures, and the three sensors were identically positioned. The images were stored in the tagged image file format provided by the systems in 8-bit depth and imported by a subtraction program. Subtractions were performed between identical images taken with the three systems. The standard deviation for the distribution of the shades of grey in the subtraction image histogram served as an expression for image noise. Paired t tests evaluated differences between the standard deviations of the subtraction images from the three systems. The standard deviation increased with increasing exposure time for all three systems (p < 0.00001). The standard deviation for the images performed with Visualix were 6.47, 10.34, and 11.16 at exposure times 0.20, 0.46, and 0.60, respectively. For the RadioVisioGraphy, these values were 1.61, 2.03, and 2.18, and for Sens-a-Ray 2.90, 3.98, and 3.96, respectively. The differences between the systems were highly statistically significant (p < 0.0001).(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Integrated CMOS-selenium x-ray detector for digital mammography

    Science.gov (United States)

    Andre, Michael P.; Spivey, Brett A.; Martin, Peter J.; Morsell, Arthur L.; Atlas, Eugene; Pellegrino, Tony

    1998-07-01

    This paper describes a novel area detector for direct conversion and readout of the x-ray energy that eliminates multiple conversions and coupling stages which degrade performance. The pixel array and readout electronics are fabricated on the same piece of silicon. The detector consists of a uniform layer (approximately 300 micrometers) of amorphous selenium alloy vapor-deposited on an electronic readout array fabricated using conventional complementary metal oxide semiconductor (CMOS). The CMOS array features 66 micrometer pixels in a 1024 X 832 array providing a 5.5 X 6.75 cm image area. Each pixel has active circuitry including signal amplification, pixel selection and reset, while peripheral circuitry on one end of the array provides shift registers, sample and hold and multiplexing. The CMOS readout array was fabricated at a standard facility on a 10-cm diameter silicon wafer using 2 micrometer CMOS process. Fifteen separate image sensors were assembled for evaluation in a 3 X 5 format to provide a 20 X 27 cm composite field of view. Missing data between sensors is recovered by acquiring three sub-exposures, between which the array is translated diagonally approximately 2 mm. Total exposure time for an average breast is less than one second. Conversion efficiency was found to be approximately 120 electrons per absorbed x-ray (19 keV average). Electronic readout noise was measured to be 2.4 ADU corresponding to approximately 500 electrons. Detective quantum efficiency was found to be 0.65 at low spatial frequency (0.25 lp/mm) and at 0.2 at high spatial frequency (8 lp/mm) for x-ray fluence ranging from 5 - 35 mR. Images of an ACR phantom show visualization of all of the fibers, specks and masses when displayed with a linear lookup table on a high-resolution monitor. These studies demonstrated that there is a slight but measurable image retention evident as 'ghost' images. The two most effective means to reduce this effect are flushing the sensors with infrared

  5. Mathematical method for optimal digitization and discrimination of scintillation detectors' pulses

    Science.gov (United States)

    Saleh, H. I.

    2015-12-01

    The crystal identification and particle identification require applying pulse shape discrimination (PSD) methods to differentiate between two or more types of scintillation pulses according to their decay times. The sampling rate and the number of used samples of scintillation pulses significantly affect the performance and the complexity of the PSD. Despite their importance, there is no method in the literature, to the best of our knowledge, regarding how to optimally select these parameters. This paper introduces a mathematical analysis of the frequency spectra to determine the most discriminated frequency band of any two different pulse-types. The proposed analysis showed that the most discriminated frequency band depends on the two decay times of the pulse-types. Based on this analysis, a digitization criterion is proposed to determine the optimum sampling rate, number of used samples and the cutoff frequency of the anti-aliasing filter. Furthermore, determining the most discriminated frequency band reduces the number of needed frequency components and provides the highest discrimination performance with the lowest number of required computations. The proposed digitization criterion is applied on two pulse-types with different decay times (20 ns and 40 ns) and shows that the most discriminated frequency is 8 MHz . It also recommends using 32 MHz sampling rate, 8 samples and an anti-aliasing filter with 10 MHz cutoff frequency for these two pulse-types.

  6. Extracting information from partially depleted Si detectors with digital sampling electronics

    Directory of Open Access Journals (Sweden)

    Pastore G.

    2015-01-01

    Full Text Available A study of the identification properties and of the energy response of a Si-Si-CsI(Tl ΔE-E telescope exploiting a partially depleted second Si stage has been performed. Five different bias voltages have been applied to the second stage of the telescope, one corresponding to full depletion, the others associated with a depleted layer ranging from 60% to 90% of the detector thickness. Fragment identification has been obtained using either the ΔE-E technique or the Pulse Shape Analysis (PSA. Charge collection efficiency has been evaluated. The ΔE-E performance is not affected by incomplete depletion. Isotopic separation capability improves at lower bias voltages with respect to full depletion, though charge identification thresholds increase.

  7. Revisited the mathematical derivation wall thickness measurement of pipe for radiography

    Energy Technology Data Exchange (ETDEWEB)

    Hamzah, A.R.; Amir, S.M.M. [Non Destructive Testing(NDT) Group, Industrial Technology Div., Malaysian Nuclear Agency, Selangor (Malaysia)

    2007-07-01

    Wall thickness measurement of pipe is very important of the structural integrity of the industrial plant. However, the radiography method has an advantage because the ability of penetrating the insulated pipe. This will have economic benefit for industry. Moreover, the era of digital radiography has more advantages because the speed of radiographic work, less exposure time and no chemical used for film development. Either the conventional radiography or digital radiology, the wall thickness measurement is using the tangential radiography technique (TRT). In case, of a large diameter, pipe (more than inches) the determination maximum penetration wall thickness must be taken into the consideration. This paper is revisited the mathematical derivation of the determination of wall thickness measurement based on tangential radiography technique (TRT). The mathematical approach used in this derivation is the Pythagoras theorem and geometrical principles. In order to derive the maximum penetration wall thickness a similar approach is used. (authors)

  8. Assessment of cold neutron radiography capability

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, T.E. Jr.; Roberts, J.A.

    1998-12-31

    This is the final report of a one-year, Laboratory Directed Research and Development (LDRD) project at Los Alamos National Laboratory (LANL). The authors goals were to demonstrate and assess cold neutron radiography techniques at the Los Alamos Neutron Science Center (LANSCE), Manual Lujan Neutron Scattering Center (Lujan Center), and to investigate potential applications of the capability. The authors have obtained images using film and an amorphous silicon detector. In addition, a new technique they have developed allows neutron radiographs to be made using only a narrow range of neutron energies. Employing this approach and the Bragg cut-off phenomena in certain materials, they have demonstrated material discrimination in radiography. They also demonstrated the imaging of cracks in a sample of a fire-set case that was supplied by Sandia National Laboratory, and they investigated whether the capability could be used to determine the extent of coking in jet engine nozzles. The LANSCE neutron radiography capability appears to have applications in the DOE stockpile maintenance and science-based stockpile stewardship (SBSS) programs, and in industry.

  9. [Comparison of dignity determination of mammographic microcalcification with two systems for digital full-field mammography with different detector resolution: a retrospective clinical study].

    Science.gov (United States)

    Schulz-Wendtland, R; Hermann, K-P; Adamietz, B; Meier-Meitinger, M; Wenkel, E; Lell, M; Anders, K; Uder, M

    2011-02-01

    The aim of this retrospective clinical study was to compare the diagnostic accuracy of the novel 50 µm FFDM (full-field digital mammography) system (DR) with an established 70 µm system (DR) in the differential diagnosis between benign and malignant clusters of microcalcification (n=50) (BI-RADS™ classification 4/5) and to assess the possible incremental value of the 50 µm pixel-pitch on specificity. From March 2009 to September 2009, 50 patients underwent full-field digital mammography (FFDM) (detector resolution 70 µm) (Novation, Siemens, Erlangen, Germany). As there were suspicious signs of microcalcification classified with BI-RADS™ 4/5 after diagnosis and preoperative wire localization, control images were made with the new FFDM system (detector: resolution 50 µm) (Amulet, Fujifilm, Tokyo, Japan) with the same exposure parameters. The diagnosis was determined after the operation by five radiologists with different experience in digital mammography from randomly distributed mediolateral views (monitor reading) whose results were correlated with the final histology of all lesions. Histopathology revealed 19 benign and 31 malignant lesions in 50 patients after open biopsy. The results of the five readers showed a higher sensitivity of the new FFDM system (80.0%) in the ability to recognize malignant microcalcification in comparison to the established system (74.8%). The specificity (75.8 versus 71.6%) was slightly higher for the new system but these results were not statistically significant (p<0.001). Considering the diagnostic accuracy, the new system (detector: resolution 50 µm) was also slightly superior to the well-known system (detector: resolution 70 µm) (80.1% versus 76.4%). Our study has shown that the new full-field digital mammography system using the novel detector compared with the already established FFDM system with respect to the assessment of microcalcification is at least equivalent.

  10. [First experiments for the detection of simulated mammographic lesions: digital full field mammography with a new detector with a double plate of pure selenium].

    Science.gov (United States)

    Schulz-Wendtland, R; Hermann, K-P; Wenkel, E; Adamietz, B; Lell, M; Anders, K; Uder, M

    2011-02-01

    The article describes an experimental phantom study of a system for digital full field mammography with a new digital detector with a double plate of pure selenium. The experiments were carried out with the new full field digital mammography system Amulet from FujiFilm. This system has a new detector (18×24 cm(2)) on the basis of highly purified amorphous selenium (a-Se) with a pixel size of 50 µm. The x-rays are converted into electric signals in the first plate which are read into the second plate with the help of an optical switch and demonstrated in the form of an image. In this way a better pixel size/volume and signal-to-noise ratio should be achieved. The object of the investigation was the Wisconsin Mammographic Random Phantom, Model 152 A (Technical Performance Mo/Mo, 28 kV, 100 mAs). Five investigators with different experiences in mammography each received three images on a monitor with different random positions of the simulated lesions in the phantom for assessment. The detection rates were compared under the same conditions with the results of two other full field digital mammography systems. The median detection rate for all images and investigators for the new doubled plated a-Se detector with optical switch was 98.7%. For both other systems with a-Si or and a-Se detectors the detection rate was 89.8% or 97.3%, respectively. There were no significant differences in the detection rate of the simulated breast lesions for all three systems considering the interobserver and intraobserver variation. The first phantom study for the detection of simulated breast lesions with the new full field digital mammography system Amulet demonstrates equivalent results with the other systems used in the clinical routine. The trend towards superiority of the new system has to be confirmed in further clinical studies.

  11. Digitization

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2014-01-01

    Processes of digitization have for years represented a major trend in the developments of modern society but have only recently been related to processes of mediatization. The purpose of this article is to look into the relation between the concepts of mediatization and digitization and to clarify...... what a concept of digital media might add to the understanding of processes of mediatization and what the concept of mediatization might add to the understanding of digital media. It is argued that digital media open an array of new trajectories in human communication, trajectories which were...... not anticipated in previous conceptualizations of media and mediatization. If digital media are to be included, the concept of mediatization has to be revised and new parameters are to be built into the concept of media. At the same time it is argued that the concept of mediatization still provides a variety...

  12. Practical guidelines for radiographers to improve computed radiography image quality

    OpenAIRE

    Pongnapang, N

    2005-01-01

    Computed Radiography (CR) has become a major digital imaging modality in a modern radiological department. CR system changes workflow from the conventional way of using film/screen by employing photostimulable phosphor plate technology. This results in the changing perspectives of technical, artefacts and quality control issues in radiology departments. Guidelines for better image quality in digital medical enterprise include professional guidelines for users and the quality control programme...

  13. Neutron radiography and tomography facility at IBR-2 reactor

    Science.gov (United States)

    Kozlenko, D. P.; Kichanov, S. E.; Lukin, E. V.; Rutkauskas, A. V.; Belushkin, A. V.; Bokuchava, G. D.; Savenko, B. N.

    2016-05-01

    An experimental station for investigations using neutron radiography and tomography was developed at the upgraded high-flux pulsed IBR-2 reactor. The 20 × 20 cm neutron beam is formed by the system of collimators with the characteristic parameter L/D varying from 200 to 2000. The detector system is based on a 6LiF/ZnS scintillation screen; images are recorded using a high-sensitivity video camera based on the high-resolution CCD matrix. The results of the first neutron radiography and tomography experiments at the developed facility are presented.

  14. Effect of comfort pads and incubator design on neonatal radiography

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Xia; Baad, Michael; Reiser, Ingrid; Feinstein, Kate A.; Lu, Zhengfeng [University of Chicago Medicine, Department of Radiology, Chicago, IL (United States)

    2016-01-15

    There has been increasing interest in patient dose reduction in neonatal intensive care units. Removing comfort pads for radiography has been identified as a potential means to decrease patient dose. To assess the effect of comfort pads and support trays on detector entrance exposure (DEE) and image quality for neonatal radiography, and its implication for patient dose. Comfort pads and support trays from three incubator and warmer systems were examined. The attenuation of the primary beam by these structures was measured using a narrow beam geometry. Their effect on DEE and image quality was then assessed using typical neonatal chest radiography techniques with three configurations: (1) both the comfort pad and support included in the beam, (2) only the support tray included and (3) both the comfort pad and support tray removed. Comfort pads and support trays were found to attenuate the primary beam by 6-15%. Eliminating these structures from the X-ray beam's path was found to increase the detector entrance exposure by 28-36% and increase contrast-to-noise ratio by more tha