  1. Scanning negatives and slides digitizing your photographic archive

    CERN Document Server

    Steinhoff, Sascha

    2009-01-01

    Many photographers have either moved into digital photography exclusively or use both analog and digital media in their work. In either case, there is sure to be an archive of slides and negatives that cannot be directly integrated into the new digital workflow, nor can it be archived in a digital format. Increasingly, photographers are trying to bridge this gap with the use of high-performance film scanners. In this 2nd edition, you will learn how to achieve the best possible digital image from a negative or a slide, and how to build a workflow to make this process efficient, repeatable, and reliable. The author uses Nikon's film scanners, but all steps can easily be accomplished while using a different scanner. The most common software tools for scanning (SilverFast, VueScan, NikonScan) are not only covered extensively in the book, but trial versions are also provided on a DVD, which also contains other useful tools for image editing, as well as numerous sample scans.

  2. Comparison of dimensional accuracy of digital dental models produced from scanned impressions and scanned stone casts

    Science.gov (United States)

    Subeihi, Haitham

    Introduction: Digital models of dental arches play a more and more important role in dentistry. A digital dental model can be generated by directly scanning intraoral structures, by scanning a conventional impression of oral structures or by scanning a stone cast poured from the conventional impression. An accurate digital scan model is a fundamental part for the fabrication of dental restorations. Aims: 1. To compare the dimensional accuracy of digital dental models produced by scanning of impressions versus scanning of stone casts. 2. To compare the dimensional accuracy of digital dental models produced by scanning of impressions made of three different materials (polyvinyl siloxane, polyether or vinyl polyether silicone). Methods and Materials: This laboratory study included taking addition silicone, polyether and vinyl polyether silicone impressions from an epoxy reference model that was created from an original typodont. Teeth number 28 and 30 on the typodont with a missing tooth number 29 were prepared for a metal-ceramic three-unit fixed dental prosthesis with tooth #29 being a pontic. After tooth preparation, an epoxy resin reference model was fabricated by duplicating the typodont quadrant that included the tooth preparations. From this reference model 12 polyvinyl siloxane impressions, 12 polyether impressions and 12 vinyl polyether silicone impressions were made. All 36 impressions were scanned before pouring them with dental stone. The 36 dental stone casts were, in turn, scanned to produce digital models. A reference digital model was made by scanning the reference model. Six groups of digital models were produced. Three groups were made by scanning of the impressions obtained with the three different materials, the other three groups involved the scanning of the dental casts that resulted from pouring the impressions made with the three different materials. Groups of digital models were compared using Root Mean Squares (RMS) in terms of their

  3. PC-based digital feedback control for scanning force microscope

    International Nuclear Information System (INIS)

    Mohd Ashhar Khalid

    2002-01-01

    In the past, most digital feedback implementation for scanned-probe microscope were based on a digital signal processor (DSP). At present DSP plug-in card with the input-output interface module is still expensive compared to a fast pentium PC motherboard. For a magnetic force microscope (MFM) digital feedback has an advantage where the magnetic signal can be easily separated from the topographic signal. In this paper, a simple low-cost PC-based digital feedback and imaging system for Scanning Force Microscope (SFM) is presented. (Author)

  4. Human Digital Modeling & Hand Scanning Lab

    Data.gov (United States)

    Federal Laboratory Consortium — This laboratory incorporates specialized scanning equipment, computer workstations and software applications for the acquisition and analysis of digitized models of...

  5. Out-of-Print Digital Scanning.

    Science.gov (United States)

    Kellerman, L. Suzanne

    2002-01-01

    Describes the in-house operational procedures developed at the Penn State University libraries to produce facsimiles of hard-to-locate, out-of-print titles using digital scanning technologies. Highlights include identification and selection, costs, copyright issues, interlibrary loan, materials preparation, and future trends. (Author/LRW)

  6. Uninformative polymorphisms bias genome scans for signatures of selection

    Directory of Open Access Journals (Sweden)

    Roesti Marius

    2012-06-01

    Full Text Available Abstract Background With the establishment of high-throughput sequencing technologies and new methods for rapid and extensive single nucleotide (SNP discovery, marker-based genome scans in search of signatures of divergent selection between populations occupying ecologically distinct environments are becoming increasingly popular. Methods and Results On the basis of genome-wide SNP marker data generated by RAD sequencing of lake and stream stickleback populations, we show that the outcome of such studies can be systematically biased if markers with a low minor allele frequency are included in the analysis. The reason is that these ‘uninformative’ polymorphisms lack the adequate potential to capture signatures of drift and hitchhiking, the focal processes in ecological genome scans. Bias associated with uninformative polymorphisms is not eliminated by just avoiding technical artifacts in the data (PCR and sequencing errors, as a high proportion of SNPs with a low minor allele frequency is a general biological feature of natural populations. Conclusions We suggest that uninformative markers should be excluded from genome scans based on empirical criteria derived from careful inspection of the data, and that these criteria should be reported explicitly. Together, this should increase the quality and comparability of genome scans, and hence promote our understanding of the processes driving genomic differentiation.

  7. A Genome-Wide Breast Cancer Scan in African Americans

    Science.gov (United States)

    2010-06-01

    SNPs from the African American breast cancer scan to COGs , a European collaborative study which is has designed a SNP array with that will be genotyped...Award Number: W81XWH-08-1-0383 TITLE: A Genome-wide Breast Cancer Scan in African Americans PRINCIPAL INVESTIGATOR: Christopher A...SUBTITLE A Genome-wide Breast Cancer Scan in African Americans 5a. CONTRACT NUMBER 5b. GRANT NUMBER W81XWH-08-1-0383 5c. PROGRAM

  8. Integration of Digital Dental Casts in Cone-Beam Computed Tomography Scans

    Science.gov (United States)

    Rangel, Frits A.; Maal, Thomas J. J.; Bergé, Stefaan J.; Kuijpers-Jagtman, Anne Marie

    2012-01-01

    Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all reported methods have drawbacks. The aim of this feasibility study is to present a new simplified method to integrate digital dental casts into CBCT scans. In a patient scheduled for orthognathic surgery, titanium markers were glued to the gingiva. Next, a CBCT scan and dental impressions were made. During the impression-taking procedure, the titanium markers were transferred to the impression. The impressions were scanned, and all CBCT datasets were exported in DICOM format. The two datasets were matched, and the dentition derived from the scanned impressions was transferred to the CBCT of the patient. After matching the two datasets, the average distance between the corresponding markers was 0.1 mm. This novel method allows for the integration of digital dental casts into CBCT scans, overcoming problems such as unwanted extra radiation exposure, distortion of soft tissues due to the use of bite jigs, and time-consuming digital data handling. PMID:23050159

  9. Genome-wide DNA polymorphism analyses using VariScan

    Directory of Open Access Journals (Sweden)

    Vilella Albert J

    2006-09-01

    Full Text Available Abstract Background DNA sequence polymorphisms analysis can provide valuable information on the evolutionary forces shaping nucleotide variation, and provides an insight into the functional significance of genomic regions. The recent ongoing genome projects will radically improve our capabilities to detect specific genomic regions shaped by natural selection. Current available methods and software, however, are unsatisfactory for such genome-wide analysis. Results We have developed methods for the analysis of DNA sequence polymorphisms at the genome-wide scale. These methods, which have been tested on a coalescent-simulated and actual data files from mouse and human, have been implemented in the VariScan software package version 2.0. Additionally, we have also incorporated a graphical-user interface. The main features of this software are: i exhaustive population-genetic analyses including those based on the coalescent theory; ii analysis adapted to the shallow data generated by the high-throughput genome projects; iii use of genome annotations to conduct a comprehensive analyses separately for different functional regions; iv identification of relevant genomic regions by the sliding-window and wavelet-multiresolution approaches; v visualization of the results integrated with current genome annotations in commonly available genome browsers. Conclusion VariScan is a powerful and flexible suite of software for the analysis of DNA polymorphisms. The current version implements new algorithms, methods, and capabilities, providing an important tool for an exhaustive exploratory analysis of genome-wide DNA polymorphism data.

  10. Integration of Digital Dental Casts in Cone-Beam Computed Tomography Scans

    OpenAIRE

    Rangel, Frits A.; Maal, Thomas J. J.; Bergé, Stefaan J.; Kuijpers-Jagtman, Anne Marie

    2012-01-01

    Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all reported methods have drawbacks. The aim of this feasibility study is to present a new simplified method to integrate digital dental casts into CBCT scans. In a patient scheduled for orthognathic ...

  11. Benefits and unexpected artifacts of biplanar digital slot-scanning imaging in children

    Energy Technology Data Exchange (ETDEWEB)

    Blumer, Steven L. [Nemours/A.I duPont Hospital for Children, Department of Medical Imaging, Wilmington, DE (United States); Dinan, David [Nemours Children' s Hospital, Orlando, FL (United States); Grissom, Leslie E. [Nemours/Alfred I. duPont Hospital for Children, Department of Radiology, Wilmington, DE (United States)

    2014-07-15

    Biplanar digital slot-scanning allows for relatively low-dose orthopedic imaging, an advantage in imaging children given the growing concerns regarding radiosensitivity. We have used this system for approximately 1 year for orthopedic imaging of the spine and lower extremities. We have noted advantages of using the digital slot-scanning system when compared with computed radiographic and standard digital radiographic imaging systems, but we also found unexpected but common imaging artifacts that are the direct result of the imaging method and that have not been reported. This pictorial essay serves to familiarize radiologists with the advantages of the digital slot-scanning system as well as imaging artifacts common with this new technology. (orig.)

  12. Surpassing digital holography limits by lensless object scanning holography.

    Science.gov (United States)

    Micó, Vicente; Ferreira, Carlos; García, Javier

    2012-04-23

    We present lensless object scanning holography (LOSH) as a fully lensless method, capable of improving image quality in reflective digital Fourier holography, by means of an extremely simplified experimental setup. LOSH is based on the recording and digital post-processing of a set of digital lensless holograms and results in a synthetic image with improved resolution, field of view (FOV), signal-to-noise ratio (SNR), and depth of field (DOF). The superresolution (SR) effect arises from the generation of a synthetic aperture (SA) based on the linear movement of the inspected object. The same scanning principle enlarges the object FOV. SNR enhancement is achieved by speckle suppression and coherent artifacts averaging due to the coherent addition of the multiple partially overlapping bandpass images. And DOF extension is performed by digital refocusing to different object's sections. Experimental results showing an impressive image quality improvement are reported for a one-dimensional reflective resolution test target. © 2012 Optical Society of America

  13. Optical scanning holography based on compressive sensing using a digital micro-mirror device

    Science.gov (United States)

    A-qian, Sun; Ding-fu, Zhou; Sheng, Yuan; You-jun, Hu; Peng, Zhang; Jian-ming, Yue; xin, Zhou

    2017-02-01

    Optical scanning holography (OSH) is a distinct digital holography technique, which uses a single two-dimensional (2D) scanning process to record the hologram of a three-dimensional (3D) object. Usually, these 2D scanning processes are in the form of mechanical scanning, and the quality of recorded hologram may be affected due to the limitation of mechanical scanning accuracy and unavoidable vibration of stepper motor's start-stop. In this paper, we propose a new framework, which replaces the 2D mechanical scanning mirrors with a Digital Micro-mirror Device (DMD) to modulate the scanning light field, and we call it OSH based on Compressive Sensing (CS) using a digital micro-mirror device (CS-OSH). CS-OSH can reconstruct the hologram of an object through the use of compressive sensing theory, and then restore the image of object itself. Numerical simulation results confirm this new type OSH can get a reconstructed image with favorable visual quality even under the condition of a low sample rate.

  14. Marginal and internal fit of zirconia copings obtained using different digital scanning methods

    Directory of Open Access Journals (Sweden)

    Lorena Oliveira PEDROCHE

    Full Text Available Abstract The objective of this study was to evaluate the marginal and internal fit of zirconia copings obtained with different digital scanning methods. A human mandibular first molar was set in a typodont with its adjacent and antagonist teeth and prepared for an all-ceramic crown. Digital impressions were made using an intraoral scanner (3Shape. Polyvinyl siloxane impressions and Type IV gypsum models were also obtained and scanned with a benchtop laboratory scanner (3Shape D700. Ten zirconia copings were fabricated for each group using CAD-CAM technology. The marginal and internal fit of the zirconia copings was assessed by the silicone replica technique. Four sections of each replica were obtained, and each section was evaluated at four points: marginal gap (MG, axial wall (AW, axio-occlusal edge (AO and centro-occlusal wall (CO, using an image analyzing software. The data were submitted to one-way ANOVA and Tukey’s test (α = 0.05. They showed statistically significant differences for MG, AO and CO. Regarding MG, intraoral scanning showed lower gap values, whereas gypsum model scanning showed higher gap values. Regarding AO and CO, intraoral digital scanning showed lower gap values. Polyvinyl siloxane impression scanning and gypsum model scanning showed higher gap values and were statistically similar. It can be concluded that intraoral digital scanning provided a lower mean gap value, in comparison with conventional impressions and gypsum casts scanned with a standard benchtop laboratory scanner.

  15. Optimization of scanning strategy of digital Shack-Hartmann wavefront sensing.

    Science.gov (United States)

    Guo, Wenjiang; Zhao, Liping; Li, Xiang; Chen, I-Ming

    2012-01-01

    In the traditional Shack-Hartmann wavefront sensing (SHWS) system, a lenslet array with a bigger configuration is desired to achieve a higher lateral resolution. However, practical implementation limits the configuration and this parameter is contradicted with the measurement range. We have proposed a digital scanning technique by making use of the high flexibility of a spatial light modulator to sample the reflected wavefront [X. Li, L. P. Zhao, Z. P. Fang, and C. S. Tan, "Improve lateral resolution in wavefront sensing with digital scanning technique," in Asia-Pacific Conference of Transducers and Micro-Nano Technology (2006)]. The lenslet array pattern is programmed to laterally scan the whole aperture. In this paper, the methodology to optimize the scanning step for the purpose of form measurement is proposed. The correctness and effectiveness are demonstrated in numerical simulation and experimental investigation. © 2012 Optical Society of America

  16. Accuracy of a computed tomography scanning procedure to manufacture digital models.

    NARCIS (Netherlands)

    Darroudi, A.M.; Kuijpers-Jagtman, A.M.; Ongkosuwito, E.M.; Suttorp, C.M.; Bronkhorst, E.M.; Breuning, K.H.

    2017-01-01

    INTRODUCTION: Accurate articulation of the digital dental casts is crucial in orthodontic diagnosis and treatment planning. We aimed to determine the accuracy of manufacturing digital dental casts from computed tomography scanning of plaster casts regarding linear dimensions and interarch

  17. Digital acquisition and processing of electron micrographs using a scanning transmission electron microscope

    International Nuclear Information System (INIS)

    Engel, A.; Christen, F.; Michel, B.

    1981-01-01

    A digital acquisition system that collects multichannel information from a scanning transmission electron microscope (STEM) and its application are described. The hardware comprises (i) single electron counting detectors, (ii) a digital scan generator, (iii) a digital multi-channel on-line processor, (iv) an interface to a minicomputer, and (v) a display system. Experimental results characterizing these components are presented, and their performance is discussed. The software includes assembler coded programs for dynamic file maintenance and fast acquisition of image data, a display driver, and FORTRAN coded application programs. The usefulness of digitized STEM is illustrated by a variety of biological applications. (orig.)

  18. Precision of guided scanning procedures for full-arch digital impressions in vivo.

    Science.gov (United States)

    Zimmermann, Moritz; Koller, Christina; Rumetsch, Moritz; Ender, Andreas; Mehl, Albert

    2017-11-01

    System-specific scanning strategies have been shown to influence the accuracy of full-arch digital impressions. Special guided scanning procedures have been implemented for specific intraoral scanning systems with special regard to the digital orthodontic workflow. The aim of this study was to evaluate the precision of guided scanning procedures compared to conventional impression techniques in vivo. Two intraoral scanning systems with implemented full-arch guided scanning procedures (Cerec Omnicam Ortho; Ormco Lythos) were included along with one conventional impression technique with irreversible hydrocolloid material (alginate). Full-arch impressions were taken three times each from 5 participants (n = 15). Impressions were then compared within the test groups using a point-to-surface distance method after best-fit model matching (OraCheck). Precision was calculated using the (90-10%)/2 quantile and statistical analysis with one-way repeated measures ANOVA and post hoc Bonferroni test was performed. The conventional impression technique with alginate showed the lowest precision for full-arch impressions with 162.2 ± 71.3 µm. Both guided scanning procedures performed statistically significantly better than the conventional impression technique (p Cerec Omnicam Ortho were 74.5 ± 39.2 µm and for group Ormco Lythos 91.4 ± 48.8 µm. The in vivo precision of guided scanning procedures exceeds conventional impression techniques with the irreversible hydrocolloid material alginate. Guided scanning procedures may be highly promising for clinical applications, especially for digital orthodontic workflows.

  19. Evaluation of the effect scan pattern has on the trueness and precision of six intraoral digital impression systems.

    Science.gov (United States)

    Mennito, Anthony S; Evans, Zachary P; Lauer, Abigail W; Patel, Ravi B; Ludlow, Mark E; Renne, Walter G

    2018-03-01

    Clinicians have been slow to adopt digital impression technologies due possibly to perceived technique sensitivities involved in data acquisition. This research has two aims: determine whether scan pattern and sequence affects the accuracy of the three-dimensional (3D) model created from this digital impression and to compare the 5 imaging systems with regards to their scanning accuracy for sextant impressions. Six digital intraoral impression systems were used to scan a typodont sextant with optical properties similar to natural teeth. The impressions were taken using five different scan patterns and the resulting digital models were overlayed on a master digital model to determine the accuracy of each scanner performing each scan pattern. Furthermore, regardless of scan pattern, each digital impression system was evaluated for accuracy to the other systems in this same manner. No differences of significance were noted in the accuracy of 3D models created using six distinct scan patterns with one exception involving the CEREC Omnicam. Planmeca Planscan was determined to be the truest scanner while 3Shape Trios was determined to be the most precise for sextant impression making. Scan pattern does not significantly affect the accuracy of the resulting digital model for sextant scanning. Companies who make digital impression systems often recommend a scan pattern specific for their system. However, every clinical scanning scenario is different and may require a different approach. Knowing how important scan pattern is with regards to accuracy would be helpful for guiding a growing number of practitioners who are utilizing this technology. © 2018 Wiley Periodicals, Inc.

  20. Micro computed tomography (CT) scanned anatomical gateway to insect pest bioinformatics

    Science.gov (United States)

    An international collaboration to establish an interactive Digital Video Library for a Systems Biology Approach to study the Asian citrus Psyllid and psyllid genomics/proteomics interactions is demonstrated. Advances in micro-CT, digital computed tomography (CT) scan uses X-rays to make detailed pic...

  1. Three-Dimensional Digital Documentation of Heritage Sites Using Terrestrial Laser Scanning and Unmanned Aerial Vehicle Photogrammetry

    Science.gov (United States)

    Jo, Y. H.; Kim, J. Y.

    2017-08-01

    Three-dimensional digital documentation is an important technique for the maintenance and monitoring of cultural heritage sites. This study focuses on the three-dimensional digital documentation of the Magoksa Temple, Republic of Korea, using a combination of terrestrial laser scanning and unmanned aerial vehicle (UAV) photogrammetry. Terrestrial laser scanning mostly acquired the vertical geometry of the buildings. In addition, the digital orthoimage produced by UAV photogrammetry had higher horizontal data acquisition rate than that produced by terrestrial laser scanning. Thus, the scanning and UAV photogrammetry were merged by matching 20 corresponding points and an absolute coordinate system was established using seven ground control points. The final, complete threedimensional shape had perfect horizontal and vertical geometries. This study demonstrates the potential of integrating terrestrial laser scanning and UAV photogrammetry for three-dimensional digital documentation. This new technique is expected to contribute to the three-dimensional digital documentation and spatial analysis of cultural heritage sites.

  2. Integration of digital dental casts in cone-beam computed tomography scans

    NARCIS (Netherlands)

    Rangel, F.A.; Maal, T.J.J.; Berge, S.J.; Kuijpers-Jagtman, A.M.

    2012-01-01

    Cone-beam computed tomography (CBCT) is widely used in maxillofacial surgery. The CBCT image of the dental arches, however, is of insufficient quality to use in digital planning of orthognathic surgery. Several authors have described methods to integrate digital dental casts into CBCT scans, but all

  3. Fine Metal Mask 3-Dimensional Measurement by using Scanning Digital Holographic Microscope

    Science.gov (United States)

    Shin, Sanghoon; Yu, Younghun

    2018-04-01

    For three-dimensional microscopy, fast and high axial resolution are very important. Extending the depth of field for digital holographic is necessary for three-dimensional measurements of thick samples. We propose an optical sectioning method for optical scanning digital holography that is performed in the frequency domain by spatial filtering of a reconstructed amplitude image. We established a scanning dual-wavelength off-axis digital holographic microscope to measure samples that exhibit a large amount of coherent noise and a thickness larger than the depth of focus of the objective lens. As a demonstration, we performed a three-dimensional measurement of a fine metal mask with a reconstructed sectional phase image and filtering with a reconstructed amplitude image.

  4. Virology: The Next Generation from Digital PCR to Single Virion Genomics

    Energy Technology Data Exchange (ETDEWEB)

    White, Richard A.; Brazelton De Cardenas, Jessica N.; Hayden, Randall T.

    2015-10-01

    In the past 25 years, virology has had major technology breakthroughs stemming first from the introduction of nucleic acid amplification testing, but more recently from the use of next-generation sequencing, digital PCR, and the possibility of single virion genomics. These technologies have and will improve diagnosis and disease state monitoring in clinical settings, aid in environmental monitoring, and reveal the vast genetic potential of viruses. Using the principle of limiting dilution, digital PCR amplifies single molecules of DNA in highly partitioned endpoint reactions and reads each of those reactions as either positive or negative based on the presence or absence of target fluorophore. In this review, digital PCR will be highlighted along with current studies, advantages/disadvantages, and future perspectives with regard to digital PCR, viral load testing, and the possibility of single virion genomics.

  5. Reliability of capturing foot parameters using digital scanning and the neutral suspension casting technique

    Science.gov (United States)

    2011-01-01

    Background A clinical study was conducted to determine the intra and inter-rater reliability of digital scanning and the neutral suspension casting technique to measure six foot parameters. The neutral suspension casting technique is a commonly utilised method for obtaining a negative impression of the foot prior to orthotic fabrication. Digital scanning offers an alternative to the traditional plaster of Paris techniques. Methods Twenty one healthy participants volunteered to take part in the study. Six casts and six digital scans were obtained from each participant by two raters of differing clinical experience. The foot parameters chosen for investigation were cast length (mm), forefoot width (mm), rearfoot width (mm), medial arch height (mm), lateral arch height (mm) and forefoot to rearfoot alignment (degrees). Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine the intra and inter-rater reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and smallest real difference (SRD). Results ICC values for all foot parameters using digital scanning ranged between 0.81-0.99 for both intra and inter-rater reliability. For neutral suspension casting technique inter-rater reliability values ranged from 0.57-0.99 and intra-rater reliability values ranging from 0.36-0.99 for rater 1 and 0.49-0.99 for rater 2. Conclusions The findings of this study indicate that digital scanning is a reliable technique, irrespective of clinical experience, with reduced measurement variability in all foot parameters investigated when compared to neutral suspension casting. PMID:21375757

  6. Impact of digital intraoral scan strategies on the impression accuracy using the TRIOS Pod scanner.

    Science.gov (United States)

    Müller, Philipp; Ender, Andreas; Joda, Tim; Katsoulis, Joannis

    2016-04-01

    Little information is available on the impact of different scan strategies on the accuracy of full-arch scans with intraoral scanners. The aim of this in-vitro study was to investigate the trueness and precision of full-arch maxillary digital impressions comparing three scan strategies. Three scan strategies (A, B, and C) were applied each five times on one single model (A, first buccal surfaces, return from occlusal-palatal; B, first occlusal-palatal, return buccal; C, S-type one-way). The TRIOS Pod scanner (3shape, Copenhagen, Denmark) with a color detector was used for these digital impressions. A cast of a maxillary dentate jaw was fabricated and scanned with an industrial reference scanner. This full-arch data record was digitally superimposed with the test scans (trueness) and within-group comparison was performed for each group (precision). The values within the 90/10 percentiles from the digital superimposition were used for calculation and group comparisons with nonparametric tests (ANOVA, post-hoc Bonferroni). The trueness (mean ± standard deviation) was 17.9 ± 16.4 μm for scan strategy A, 17.1 ± 13.7 μm for B, and 26.8 ± 14.7 μm for C without statistically significant difference. The precision was lowest for scan strategy A (35.0 ± 51.1 μm) and significantly different to B (7.9 ± 5.6 μm) and C (8.5 ± 6.3 μm). Scan strategy B may be recommended as it provides the highest trueness and precision in full-arch scans and therefore minimizes inaccuracies in the final reconstruction.

  7. A digital gigapixel large-format tile-scan camera.

    Science.gov (United States)

    Ben-Ezra, M

    2011-01-01

    Although the resolution of single-lens reflex (SLR) and medium-format digital cameras has increased in recent years, applications for cultural-heritage preservation and computational photography require even higher resolutions. Addressing this issue, a large-format cameras' large image planes can achieve very high resolution without compromising pixel size and thus can provide high-quality, high-resolution images.This digital large-format tile scan camera can acquire high-quality, high-resolution images of static scenes. It employs unique calibration techniques and a simple algorithm for focal-stack processing of very large images with significant magnification variations. The camera automatically collects overlapping focal stacks and processes them into a high-resolution, extended-depth-of-field image.

  8. Full arch scans: conventional versus digital impressions--an in-vitro study.

    Science.gov (United States)

    Ender, A; Mehl, A

    2011-01-01

    The digital intraoral impression has become a central part of the CAD/CAM technique. The objective of the present study was to compare the accuracy (trueness and precision) of digital impressions of the full arch with that of conventional impressions on the in-vitro model. For this purpose, a master model was acquired with a new reference scanning process, the measuring trueness of which was +/- 4.1 microm and the precision +/- 2.5 microm. On the one hand, conventional impressions and then plaster models (n = 5) were produced from this master model, and on the other hand, digital impressions were made with the Cerec AC Bluecam and the Lava COS system (each n = 5). The plaster models were also scanned with the reference scanner. The available data records were superimposed and the differences determined. The deviation from the master model defines the trueness of the impression method. The deviations of the models among one another demonstrate the precision of the method. The trueness of the impressions was 55 +/- 21.8 microm in the conventional impression group, for digital impressions with Cerec Bluecam it was 49 +/- 14.2 microm and for digital impressions with Lava COS 40.3 +/- 14.1 microm. The precision was 61.3 +/- 17.9 microm for conventional impression with Impregum, 30.9 +/- 7.1 microm for digital impression with the Cerec Bluecam and 60.1 +/- 31.3 microm for digital impression with Lava COS. These in-vitro results show that accuracy of the digital impression is similar to that of the conventional impression. These results will have to be confirmed in further clinical studies.

  9. A simplified digital lock-in amplifier for the scanning grating spectrometer.

    Science.gov (United States)

    Wang, Jingru; Wang, Zhihong; Ji, Xufei; Liu, Jie; Liu, Guangda

    2017-02-01

    For the common measurement and control system of a scanning grating spectrometer, the use of an analog lock-in amplifier requires complex circuitry and sophisticated debugging, whereas the use of a digital lock-in amplifier places a high demand on the calculation capability and storage space. In this paper, a simplified digital lock-in amplifier based on averaging the absolute values within a complete period is presented and applied to a scanning grating spectrometer. The simplified digital lock-in amplifier was implemented on a low-cost microcontroller without multipliers, and got rid of the reference signal and specific configuration of the sampling frequency. Two positive zero-crossing detections were used to lock the phase of the measured signal. However, measurement method errors were introduced by the following factors: frequency fluctuation, sampling interval, and integer restriction of the sampling number. The theoretical calculation and experimental results of the signal-to-noise ratio of the proposed measurement method were 2055 and 2403, respectively.

  10. Automatic scanning of Cerenkov light photograms from a multistep avalanche chamber using a television digitizer

    International Nuclear Information System (INIS)

    Vascon, M.; Zanella, G.

    1980-01-01

    A television digitizer and its application to automatic scanning of Cerenkov imaging using the multistep avalanche chamber in front of optical spark chamber are described. The results are of interest in the adoption of the automatic scanning of photographic plates of these events or for the on-line application of the television digitizer itself. (orig.)

  11. Accuracy and Reliability of a Novel Method for Fusion of Digital Dental Casts and Cone Beam Computed Tomography Scans

    Science.gov (United States)

    Rangel, Frits A.; Maal, Thomas J. J.; Bronkhorst, Ewald M.; Breuning, K. Hero; Schols, Jan G. J. H.; Bergé, Stefaan J.; Kuijpers-Jagtman, Anne Marie

    2013-01-01

    Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods. PMID:23527111

  12. Accuracy and reliability of a novel method for fusion of digital dental casts and Cone Beam Computed Tomography scans.

    Directory of Open Access Journals (Sweden)

    Frits A Rangel

    Full Text Available Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental casts into Cone Beam Computed Tomography scans. Plaster casts of 10 patients were randomly selected and 5 titanium markers were glued to the upper and lower plaster cast. The plaster models were scanned, impressions were taken from the plaster models and the impressions were also scanned. Linear measurements were performed on all three models, to assess accuracy and reproducibility. Besides that, matching of the scanned plaster models and scanned impressions was done, to assess the accuracy of the matching procedure. Results show that all measurement errors are smaller than 0.2 mm, and that 81% is smaller than 0.1 mm. Matching of the scanned plaster casts and scanned impressions show a mean error between the two surfaces of the upper arch of 0.14 mm and for the lower arch of 0.18 mm. The time needed for reconstructing the CBCT scans to a digital patient, where the impressions are integrated into the CBCT scan of the patient takes about 15 minutes, with little variance between patients. In conclusion, we can state that this new method is a reliable method to integrate digital dental casts into CBCT scans. As far as radiation exposure, soft tissue deformation and digital handling processes are concerned, it is a significant improvement compared to the previously published methods.

  13. Digital examination and transvaginal scan - competing or complementary for predicting preterm birth?

    DEFF Research Database (Denmark)

    Reiter, Eva; Nielsen, Kurt Aagaard; Fedder, Jens

    2012-01-01

    The transvaginal ultrasonographic cervix scan has partly replaced digital examination for diagnosing preterm birth; conflicting results are reported about their respective contribution to birth prediction....

  14. Effects of scanning resolution and digital image magnification on photostimulable phosphor imaging system

    International Nuclear Information System (INIS)

    Sakurai, Takashi; Inagaki, Masafumi; Asai, Hideomi; Koyama, Atsushi; Kashima, Isamu

    2000-01-01

    The purpose of this study is to examine the effects of changes in scanning resolution and digital magnification on the image quality and diagnostic ability of the photostimulable phosphor imaging system. Using a photostimulable phosphor imaging system, images of a human adult dried mandible phantom embedded in a 25 mm-thick epoxy resin block were made. The latent images on the photostimulable phosphor imaging plate were scanned using four different pixel sizes as follows: 25 μm x 25 μm, 50 μm x 50 μm, 100 μm x 100 μm and 200 μm x 200 μm. A primary image was produced for each pixel size. These images were also digitally magnified at powers of 2, 4 and 8 times. The gradient range, brightness and contrast of each image were adjusted to optimum levels on a cathode ray tube display, and hard copies were produced with a writing pixel size of 60 μm x 60 μm. The granularity, sharpness and anatomical diagnostic ability of the images were assessed subjectively by eight dentists. Increasing the scanning resolution tended to generally improve image quality and diagnostic ability. Visual image quality was maintained up to a pixel size of 50 μm, and diagnostic ability was maintained up to a pixel size of 100 μm. Digital image magnification degraded image quality, and more than 2-times magnification degraded diagnostic ability. Under the present experimental conditions, increasing the scanning resolution did not always lead to an improvement in image quality or diagnostic ability, and digital image magnification degraded image quality and diagnostic ability. (author)

  15. Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging

    International Nuclear Information System (INIS)

    Liu Xinming; Shaw, Chris C.; Lai, Chao-Jen; Wang Tianpeng

    2011-01-01

    Purpose: To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. Methods: A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full

  16. Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging

    Energy Technology Data Exchange (ETDEWEB)

    Liu Xinming; Shaw, Chris C.; Lai, Chao-Jen; Wang Tianpeng [Department of Imaging Physics, Digital Imaging Research Laboratory, University of Texas M. D. Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2011-01-15

    Purpose: To investigate and compare the scatter rejection properties and low-contrast performance of the scan equalization digital radiography (SEDR) technique to the slot-scan and conventional full-field digital radiography techniques for chest imaging. Methods: A prototype SEDR system was designed and constructed with an a-Se flat-panel (FP) detector to improve image quality in heavily attenuating regions of an anthropomorphic chest phantom. Slot-scanning geometry was used to reject scattered radiation without attenuating primary x rays. The readout scheme of the FP was modified to erase accumulated scatter signals prior to image readout. A 24-segment beam width modulator was developed to regulate x-ray exposures regionally and compensate for the low x-ray flux in heavily attenuating regions. To measure the scatter-to-primary ratios (SPRs), a 2 mm thick lead plate with a 2-D array of aperture holes was used to measure the primary signals, which were then subtracted from those obtained without the lead plate to determine scatter components. A 2-D array of aluminum beads (3 mm in diameter) was used as the low-contrast objects to measure the contrast ratios (CRs) and contrast-to-noise ratios (CNRs) for evaluating the low-contrast performance in chest phantom images. A set of two images acquired with the same techniques were subtracted from each other to measure the noise levels. SPRs, CRs, and CNRs of the SEDR images were measured in four anatomical regions of chest phantom images and compared to those of slot-scan images and full-field images acquired with and without antiscatter grid. Results: The percentage reduction of SPR (percentage of SPRs reduced with scatter removal/rejection methods relative to that for nongrid full-field imaging) averaged over four anatomical regions was measured to be 80%, 83%, and 71% for SEDR, slot-scan, and full-field with grid, respectively. The average CR over four regions was found to improve over that for nongrid full

  17. Combined amplification and hybridization techniques for genome scanning in vegetatively propagated crops

    International Nuclear Information System (INIS)

    Kahl, G.; Ramser, J.; Terauchi, R.; Lopez-Peralta, C.; Asemota, H.N.; Weising, K.

    1998-01-01

    A combination of PCR- and hybridization-based genome scanning techniques and sequence comparisons between non-coding chloroplast DNA flanking tRNA genes has been employed to screen Dioscorea species for intra- and interspecific genetic diversity. This methodology detected extensive polymorphisms within Dioscorea bulbifera L., and revealed taxonomic and phylogenetic relationships among cultivated Guinea yams varieties and their potential wild progenitors. Finally, screening of yam germplasm grown in Jamaica permitted reliable discrimination between all major cultivars. Genome scanning by micro satellite-primed PCR (MP-PCR) and random amplified polymorphic DNA (RAPD) analysis in combination with the novel random amplified micro satellite polymorphisms (RAMPO) hybridization technique has shown high potential for the genetic analysis of yams, and holds promise for other vegetatively propagated orphan crops. (author)

  18. Digital radiographic scanning installation with multiwire proportional chamber

    International Nuclear Information System (INIS)

    Babichev, E.A.; Baru, S.E.; Khabakhpashev, A.G.; Kolachev, G.M.; Savinov, G.A.; Shekhtman, L.I.; Sidorov, V.A.; Volobuev, A.I.

    1991-01-01

    A digital radiographic installation for medical diagnostics is described. Distribution of X-ray intensity in horizontal direction is measured by a one-coordinate MWPC with a 1.2 mm channel. A two-dimensional image is produced by mechanical scanning with 1 mm channel width in vertical direction. The number of pixels in the image is 320x256. The MWPC works in count mode with quantum efficiency 25% (50 keV) and count rate capability 600 kHz/channel. Results of testing a prototype with 64 channels 0.6 mm width are also presented. (orig.)

  19. Digital radiography of scoliosis with a scanning method: radiation dose optimization

    Energy Technology Data Exchange (ETDEWEB)

    Geijer, Haakan; Andersson, Torbjoern [Department of Radiology, Oerebro University Hospital, 701 85 Oerebro (Sweden); Verdonck, Bert [Philips Medical Systems, P.O. Box 10,000, 5680 Best (Netherlands); Beckman, Karl-Wilhelm; Persliden, Jan [Department of Medical Physics, Oerebro University Hospital, 701 85 Oerebro (Sweden)

    2003-03-01

    The aim of this study was optimization of the radiation dose-image quality relationship for a digital scanning method of scoliosis radiography. The examination is performed as a digital multi-image translation scan that is reconstructed to a single image in a workstation. Entrance dose was recorded with thermoluminescent dosimeters placed dorsally on an Alderson phantom. At the same time, kerma area product (KAP) values were recorded. A Monte Carlo calculation of effective dose was also made. Image quality was evaluated with a contrast-detail phantom and Visual Grading. The radiation dose was reduced by lowering the image intensifier entrance dose request, adjusting pulse frequency and scan speed, and by raising tube voltage. The calculated effective dose was reduced from 0.15 to 0.05 mSv with reduction of KAP from 1.07 to 0.25 Gy cm{sup 2} and entrance dose from 0.90 to 0.21 mGy. The image quality was reduced with the Image Quality Figure going from 52 to 62 and a corresponding reduction in image quality as assessed with Visual Grading. The optimization resulted in a dose reduction to 31% of the original effective dose with an acceptable reduction in image quality considering the intended use of the images for angle measurements. (orig.)

  20. ODK Scan: Digitizing Data Collection and Impacting Data Management Processes in Pakistan’s Tuberculosis Control Program

    Directory of Open Access Journals (Sweden)

    Syed Mustafa Ali

    2016-10-01

    Full Text Available The present grievous tuberculosis situation can be improved by efficient case management and timely follow-up evaluations. With the advent of digital technology, this can be achieved through quick summarization of the patient-centric data. The aim of our study was to assess the effectiveness of the ODK Scan paper-to-digital system during a testing period of three months. A sequential, explanatory mixed-method research approach was employed to elucidate technology use. Training, smartphones, the application and 3G-enabled SIMs were provided to the four field workers. At the beginning, baseline measures of the data management aspects were recorded and compared with endline measures to determine the impact of ODK Scan. Additionally, at the end of the study, users’ feedback was collected regarding app usability, user interface design and workflow changes. A total of 122 patients’ records were retrieved from the server and analysed in terms of quality. It was found that ODK Scan recognized 99.2% of multiple choice fill-in bubble responses and 79.4% of numerical digit responses correctly. However, the overall quality of the digital data was decreased in comparison to manually entered data. Using ODK Scan, a significant time reduction is observed in data aggregation and data transfer activities, but data verification and form-filling activities took more time. Interviews revealed that field workers saw value in using ODK Scan, but they were more concerned about the time-consuming aspects of the use of ODK Scan. Therefore, it is concluded that minimal disturbance in the existing workflow, continuous feedback and value additions are the important considerations for the implementing organization to ensure technology adoption and workflow improvements.

  1. Synchronous digitization for high dynamic range lock-in amplification in beam-scanning microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Muir, Ryan D.; Sullivan, Shane Z.; Oglesbee, Robert A.; Simpson, Garth J., E-mail: gsimpson@purdue.edu [Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, Indiana 47907 (United States)

    2014-03-15

    Digital lock-in amplification (LIA) with synchronous digitization (SD) is shown to provide significant signal to noise (S/N) and linear dynamic range advantages in beam-scanning microscopy measurements using pulsed laser sources. Direct comparisons between SD-LIA and conventional LIA in homodyne second harmonic generation measurements resulted in S/N enhancements consistent with theoretical models. SD-LIA provided notably larger S/N enhancements in the limit of low light intensities, through the smooth transition between photon counting and signal averaging developed in previous work. Rapid beam scanning instrumentation with up to video rate acquisition speeds minimized photo-induced sample damage. The corresponding increased allowance for higher laser power without sample damage is advantageous for increasing the observed signal content.

  2. Combined amplification and hybridization techniques for genome scanning in vegetatively propagated crops

    Energy Technology Data Exchange (ETDEWEB)

    Kahl, G; Ramser, J; Terauchi, R [Biocentre, University of Frankfurt, Frankfurt am Main (Germany); Lopez-Peralta, C [IRGP, Colegio de Postgraduados, Montecillo, Edo. de Mexico, Texcoco (Mexico); Asemota, H N [Biotechnology Centre, University of the West Indies, Mona, Kingston (Jamaica); Weising, K [School of Biological Sciences, University of Auckland, Auckland (New Zealand)

    1998-10-01

    A combination of PCR- and hybridization-based genome scanning techniques and sequence comparisons between non-coding chloroplast DNA flanking tRNA genes has been employed to screen Dioscorea species for intra- and interspecific genetic diversity. This methodology detected extensive polymorphisms within Dioscorea bulbifera L., and revealed taxonomic and phylogenetic relationships among cultivated Guinea yams varieties and their potential wild progenitors. Finally, screening of yam germplasm grown in Jamaica permitted reliable discrimination between all major cultivars. Genome scanning by micro satellite-primed PCR (MP-PCR) and random amplified polymorphic DNA (RAPD) analysis in combination with the novel random amplified micro satellite polymorphisms (RAMPO) hybridization technique has shown high potential for the genetic analysis of yams, and holds promise for other vegetatively propagated orphan crops. (author) 46 refs, 3 figs, 3 tabs

  3. T-scan III system diagnostic tool for digital occlusal analysis in orthodontics - a modern approach.

    Science.gov (United States)

    Trpevska, Vesna; Kovacevska, Gordana; Benedeti, Alberto; Jordanov, Bozidar

    2014-01-01

    This systematic literature review was performed to establish the mechanism, methodology, characteristics, clinical application and opportunities of the T-Scan III System as a diagnostic tool for digital occlusal analysis in different fields of dentistry, precisely in orthodontics. Searching of electronic databases, using MEDLINE and PubMed, hand searching of relevant key journals, and screening of reference lists of included studies with no language restriction was performed. Publications providing statistically examined data were included for systematic review. Twenty potentially relevant Randomized Controlled Trials (RCTs) were identified. Only ten met the inclusion criteria. The literature demonstrates that using digital occlusal analysis with T-Scan III System in orthodontics has significant advantage with regard to the capability of measuring occlusal parameters in static positions and during dynamic of the mandible. Within the scope of this systematic review, there is evidence to support that T-Scan system is rapid and accurate in identifying the distribution of the tooth contacts and it shows great promise as a clinical diagnostic screening device for occlusion and for improving the occlusion after various dental treatments. Additional clinical studies are required to advance the indication filed of this system. Importance of using digital occlusal T-Scan analysis in orthodontics deserves further investigation.

  4. An empirical Bayes method for updating inferences in analysis of quantitative trait loci using information from related genome scans.

    Science.gov (United States)

    Zhang, Kui; Wiener, Howard; Beasley, Mark; George, Varghese; Amos, Christopher I; Allison, David B

    2006-08-01

    Individual genome scans for quantitative trait loci (QTL) mapping often suffer from low statistical power and imprecise estimates of QTL location and effect. This lack of precision yields large confidence intervals for QTL location, which are problematic for subsequent fine mapping and positional cloning. In prioritizing areas for follow-up after an initial genome scan and in evaluating the credibility of apparent linkage signals, investigators typically examine the results of other genome scans of the same phenotype and informally update their beliefs about which linkage signals in their scan most merit confidence and follow-up via a subjective-intuitive integration approach. A method that acknowledges the wisdom of this general paradigm but formally borrows information from other scans to increase confidence in objectivity would be a benefit. We developed an empirical Bayes analytic method to integrate information from multiple genome scans. The linkage statistic obtained from a single genome scan study is updated by incorporating statistics from other genome scans as prior information. This technique does not require that all studies have an identical marker map or a common estimated QTL effect. The updated linkage statistic can then be used for the estimation of QTL location and effect. We evaluate the performance of our method by using extensive simulations based on actual marker spacing and allele frequencies from available data. Results indicate that the empirical Bayes method can account for between-study heterogeneity, estimate the QTL location and effect more precisely, and provide narrower confidence intervals than results from any single individual study. We also compared the empirical Bayes method with a method originally developed for meta-analysis (a closely related but distinct purpose). In the face of marked heterogeneity among studies, the empirical Bayes method outperforms the comparator.

  5. SINE_scan: an efficient tool to discover short interspersed nuclear elements (SINEs) in large-scale genomic datasets.

    Science.gov (United States)

    Mao, Hongliang; Wang, Hao

    2017-03-01

    Short Interspersed Nuclear Elements (SINEs) are transposable elements (TEs) that amplify through a copy-and-paste mode via RNA intermediates. The computational identification of new SINEs are challenging because of their weak structural signals and rapid diversification in sequences. Here we report SINE_Scan, a highly efficient program to predict SINE elements in genomic DNA sequences. SINE_Scan integrates hallmark of SINE transposition, copy number and structural signals to identify a SINE element. SINE_Scan outperforms the previously published de novo SINE discovery program. It shows high sensitivity and specificity in 19 plant and animal genome assemblies, of which sizes vary from 120 Mb to 3.5 Gb. It identifies numerous new families and substantially increases the estimation of the abundance of SINEs in these genomes. The code of SINE_Scan is freely available at http://github.com/maohlzj/SINE_Scan , implemented in PERL and supported on Linux. wangh8@fudan.edu.cn. Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press.

  6. Digitally controlled analog proportional-integral-derivative (PID) controller for high-speed scanning probe microscopy

    Science.gov (United States)

    Dukic, Maja; Todorov, Vencislav; Andany, Santiago; Nievergelt, Adrian P.; Yang, Chen; Hosseini, Nahid; Fantner, Georg E.

    2017-12-01

    Nearly all scanning probe microscopes (SPMs) contain a feedback controller, which is used to move the scanner in the direction of the z-axis in order to maintain a constant setpoint based on the tip-sample interaction. The most frequently used feedback controller in SPMs is the proportional-integral (PI) controller. The bandwidth of the PI controller presents one of the speed limiting factors in high-speed SPMs, where higher bandwidths enable faster scanning speeds and higher imaging resolution. Most SPM systems use digital signal processor-based PI feedback controllers, which require analog-to-digital and digital-to-analog converters. These converters introduce additional feedback delays which limit the achievable imaging speed and resolution. In this paper, we present a digitally controlled analog proportional-integral-derivative (PID) controller. The controller implementation allows tunability of the PID gains over a large amplification and frequency range, while also providing precise control of the system and reproducibility of the gain parameters. By using the analog PID controller, we were able to perform successful atomic force microscopy imaging of a standard silicon calibration grating at line rates up to several kHz.

  7. Comparison of conventional study model measurements and 3D digital study model measurements from laser scanned dental impressions

    Science.gov (United States)

    Nugrahani, F.; Jazaldi, F.; Noerhadi, N. A. I.

    2017-08-01

    The field of orthodontics is always evolving,and this includes the use of innovative technology. One type of orthodontic technology is the development of three-dimensional (3D) digital study models that replace conventional study models made by stone. This study aims to compare the mesio-distal teeth width, intercanine width, and intermolar width measurements between a 3D digital study model and a conventional study model. Twelve sets of upper arch dental impressions were taken from subjects with non-crowding teeth. The impressions were taken twice, once with alginate and once with polivinylsiloxane. The alginate impressions used in the conventional study model and the polivinylsiloxane impressions were scanned to obtain the 3D digital study model. Scanning was performed using a laser triangulation scanner device assembled by the School of Electrical Engineering and Informatics at the Institut Teknologi Bandung and David Laser Scan software. For the conventional model, themesio-distal width, intercanine width, and intermolar width were measured using digital calipers; in the 3D digital study model they were measured using software. There were no significant differences between the mesio-distal width, intercanine width, and intermolar width measurments between the conventional and 3D digital study models (p>0.05). Thus, measurements using 3D digital study models are as accurate as those obtained from conventional study models

  8. Digitally generated excitation and near-baseband quadrature detection of rapid scan EPR signals.

    Science.gov (United States)

    Tseitlin, Mark; Yu, Zhelin; Quine, Richard W; Rinard, George A; Eaton, Sandra S; Eaton, Gareth R

    2014-12-01

    The use of multiple synchronized outputs from an arbitrary waveform generator (AWG) provides the opportunity to perform EPR experiments differently than by conventional EPR. We report a method for reconstructing the quadrature EPR spectrum from periodic signals that are generated with sinusoidal magnetic field modulation such as continuous wave (CW), multiharmonic, or rapid scan experiments. The signal is down-converted to an intermediate frequency (IF) that is less than the field scan or field modulation frequency and then digitized in a single channel. This method permits use of a high-pass analog filter before digitization to remove the strong non-EPR signal at the IF, that might otherwise overwhelm the digitizer. The IF is the difference between two synchronized X-band outputs from a Tektronix AWG 70002A, one of which is for excitation and the other is the reference for down-conversion. To permit signal averaging, timing was selected to give an exact integer number of full cycles for each frequency. In the experiments reported here the IF was 5kHz and the scan frequency was 40kHz. To produce sinusoidal rapid scans with a scan frequency eight times IF, a third synchronized output generated a square wave that was converted to a sine wave. The timing of the data acquisition with a Bruker SpecJet II was synchronized by an external clock signal from the AWG. The baseband quadrature signal in the frequency domain was reconstructed. This approach has the advantages that (i) the non-EPR response at the carrier frequency is eliminated, (ii) both real and imaginary EPR signals are reconstructed from a single physical channel to produce an ideal quadrature signal, and (iii) signal bandwidth does not increase relative to baseband detection. Spectra were obtained by deconvolution of the reconstructed signals for solid BDPA (1,3-bisdiphenylene-2-phenylallyl) in air, 0.2mM trityl OX63 in water, 15 N perdeuterated tempone, and a nitroxide with a 0.5G partially-resolved proton

  9. Meta-analysis of genome-wide linkage scans of attention deficit hyperactivity disorder

    NARCIS (Netherlands)

    Zhou, K.; Dempfle, A.; Arcos-Burgos, M.; Bakker, S.C.; Banaschewski, T.; Biederman, J; Buitelaar, J.K.; Castellanos, F.X.; Doyle, A.; Ebstein, R.; Ekholm, J.; Forabosco, P.; Franke, F.; Freitag, C.; Friedel, S.; Gill, M.; Hebebrand, J.; Hinney, A.; Jacob, C.; Lesch, K.P.; Loo, S.K.; Lopera, F.; McCracken, J.T.; McGough, J.J.; Meyer, J.; Mick, E.; Miranda, A.; Muenkel, M.; Mulas, F.; Nelson, S.F.; Nguyen, T.T.; Oades, R.D.; Ogdie, M.N.; Palacio, J.D.; Pineda, D.; Reif, A.; Renner, T.J.; Roeyers, H.; Romanos, M.; Rothenberger, A.; Schäfer, H.; Sergeant, J.A.; Sinke, R.J.; Smalley, S.L.; Sonuga-Barke, E.; Steinhausen, H.C.; van der Meulen, E.; Walitza, S.; Warnke, A.; Lewis, C.M.; Faraone, S.V.; Asherson, P.

    2008-01-01

    Genetic contribution to the development of attention deficit hyperactivity disorder (ADHD) is well established. Seven independent genome-wide linkage scans have been performed to map loci that increase the risk for ADHD. Although significant linkage signals were identified in some of the studies,

  10. Meta-analysis of genome-wide linkage scans of attention deficit hyperactivity disorder.

    NARCIS (Netherlands)

    Zhou, K.; Dempfle, A.; Arcos-Burgos, M.; Bakker, S.C.; Banaschewski, T.; Biederman, J.; Buitelaar, J.K.; Castellanos, F.X.; Doyle, A.; Ebstein, R.P.; Ekholm, J.; Forabosco, P.; Franke, B.; Freitag, C.; Friedel, S.; Gill, M.; Hebebrand, J.; Hinney, A.; Jacob, C.; Lesch, K.P.; Loo, S.K.; Lopera, F.; McCracken, J.T.; McGough, J.J.; Meyer, J.; Mick, E.; Miranda, A.; Muenke, M.; Mulas, F.; Nelson, S.F.; Nguyen, T.T.; Oades, R.D.; Ogdie, M.N.; Palacio, J.D.; Pineda, D.; Reif, A.; Renner, T.J.; Roeyers, H.; Romanos, M.; Rothenberger, A.; Schafer, H.; Sergeant, J.A.; Sinke, R.J.; Smalley, S.L.; Sonuga-Barke, E.J.S.; Steinhausen, H.C.; Meulen, E. van der; Walitza, S.; Warnke, A.; Lewis, C.M.; Faraone, S.V.; Asherson, P.

    2008-01-01

    Genetic contribution to the development of attention deficit hyperactivity disorder (ADHD) is well established. Seven independent genome-wide linkage scans have been performed to map loci that increase the risk for ADHD. Although significant linkage signals were identified in some of the studies,

  11. Multiple Hotspot Mutations Scanning by Single Droplet Digital PCR.

    Science.gov (United States)

    Decraene, Charles; Silveira, Amanda B; Bidard, François-Clément; Vallée, Audrey; Michel, Marc; Melaabi, Samia; Vincent-Salomon, Anne; Saliou, Adrien; Houy, Alexandre; Milder, Maud; Lantz, Olivier; Ychou, Marc; Denis, Marc G; Pierga, Jean-Yves; Stern, Marc-Henri; Proudhon, Charlotte

    2018-02-01

    Progress in the liquid biopsy field, combined with the development of droplet digital PCR (ddPCR), has enabled noninvasive monitoring of mutations with high detection accuracy. However, current assays detect a restricted number of mutations per reaction. ddPCR is a recognized method for detecting alterations previously characterized in tumor tissues, but its use as a discovery tool when the mutation is unknown a priori remains limited. We established 2 ddPCR assays detecting all genomic alterations within KRAS exon 2 and EGFR exon 19 mutation hotspots, which are of clinical importance in colorectal and lung cancer, with use of a unique pair of TaqMan ® oligoprobes. The KRAS assay scanned for the 7 most common mutations in codons 12/13 but also all other mutations found in that region. The EGFR assay screened for all in-frame deletions of exon 19, which are frequent EGFR-activating events. The KRAS and EGFR assays were highly specific and both reached a limit of detection of <0.1% in mutant allele frequency. We further validated their performance on multiple plasma and formalin-fixed and paraffin-embedded tumor samples harboring a panel of different KRAS or EGFR mutations. This method presents the advantage of detecting a higher number of mutations with single-reaction ddPCRs while consuming a minimum of patient sample. This is particularly useful in the context of liquid biopsy because the amount of circulating tumor DNA is often low. This method should be useful as a discovery tool when the tumor tissue is unavailable or to monitor disease during therapy. © 2017 American Association for Clinical Chemistry.

  12. Accounting for linkage disequilibrium in genome scans for selection without individual genotypes: The local score approach.

    Science.gov (United States)

    Fariello, María Inés; Boitard, Simon; Mercier, Sabine; Robelin, David; Faraut, Thomas; Arnould, Cécile; Recoquillay, Julien; Bouchez, Olivier; Salin, Gérald; Dehais, Patrice; Gourichon, David; Leroux, Sophie; Pitel, Frédérique; Leterrier, Christine; SanCristobal, Magali

    2017-07-01

    Detecting genomic footprints of selection is an important step in the understanding of evolution. Accounting for linkage disequilibrium in genome scans increases detection power, but haplotype-based methods require individual genotypes and are not applicable on pool-sequenced samples. We propose to take advantage of the local score approach to account for linkage disequilibrium in genome scans for selection, cumulating (possibly small) signals from single markers over a genomic segment, to clearly pinpoint a selection signal. Using computer simulations, we demonstrate that this approach detects selection with higher power than several state-of-the-art single-marker, windowing or haplotype-based approaches. We illustrate this on two benchmark data sets including individual genotypes, for which we obtain similar results with the local score and one haplotype-based approach. Finally, we apply the local score approach to Pool-Seq data obtained from a divergent selection experiment on behaviour in quail and obtain precise and biologically coherent selection signals: while competing methods fail to highlight any clear selection signature, our method detects several regions involving genes known to act on social responsiveness or autistic traits. Although we focus here on the detection of positive selection from multiple population data, the local score approach is general and can be applied to other genome scans for selection or other genomewide analyses such as GWAS. © 2017 John Wiley & Sons Ltd.

  13. Comparison of Bolton analysis and Little’s irregularity index on laser scanned three-dimensional digital study models with conventional study models

    Science.gov (United States)

    Kurnia, H.; Noerhadi, N. A. I.

    2017-08-01

    Three-dimensional digital study models were introduced following advances in digital technology. This study was carried out to assess the reliability of digital study models scanned by a laser scanning device newly assembled. The aim of this study was to compare the digital study models and conventional models. Twelve sets of dental impressions were taken from patients with mild-to-moderate crowding. The impressions were taken twice, one with alginate and the other with polyvinylsiloxane. The alginate impressions were made into conventional models, and the polyvinylsiloxane impressions were scanned to produce digital models. The mesiodistal tooth width and Little’s irregularity index (LII) were measured manually with digital calipers on the conventional models and digitally on the digital study models. Bolton analysis was performed on each study models. Each method was carried out twice to check for intra-observer variability. The reproducibility (comparison of the methods) was assessed using independent-sample t-tests. The mesiodistal tooth width between conventional and digital models did not significantly differ (p > 0.05). Independent-sample t-tests did not identify statistically significant differences for Bolton analysis and LII (p = 0.603 for Bolton and p = 0894 for LII). The measurements of the digital study models are as accurate as those of the conventional models.

  14. AFLP genome scans suggest divergent selection on colour patterning in allopatric colour morphs of a cichlid fish.

    Science.gov (United States)

    Mattersdorfer, Karin; Koblmüller, Stephan; Sefc, Kristina M

    2012-07-01

    Genome scan-based tests for selection are directly applicable to natural populations to study the genetic and evolutionary mechanisms behind phenotypic differentiation. We conducted AFLP genome scans in three distinct geographic colour morphs of the cichlid fish Tropheus moorii to assess whether the extant, allopatric colour pattern differentiation can be explained by drift and to identify markers mapping to genomic regions possibly involved in colour patterning. The tested morphs occupy adjacent shore sections in southern Lake Tanganyika and are separated from each other by major habitat barriers. The genome scans revealed significant genetic structure between morphs, but a very low proportion of loci fixed for alternative AFLP alleles in different morphs. This high level of polymorphism within morphs suggested that colour pattern differentiation did not result exclusively from neutral processes. Outlier detection methods identified six loci with excess differentiation in the comparison between a bluish and a yellow-blotch morph and five different outlier loci in comparisons of each of these morphs with a red morph. As population expansions and the genetic structure of Tropheus make the outlier approach prone to false-positive signals of selection, we examined the correlation between outlier locus alleles and colour phenotypes in a genetic and phenotypic cline between two morphs. Distributions of allele frequencies at one outlier locus were indeed consistent with linkage to a colour locus. Despite the challenges posed by population structure and demography, our results encourage the cautious application of genome scans to studies of divergent selection in subdivided and recently expanded populations. © 2012 Blackwell Publishing Ltd.

  15. Terrestrial scanning or digital images in inventory of monumental objects? - case study

    Science.gov (United States)

    Markiewicz, J. S.; Zawieska, D.

    2014-06-01

    Cultural heritage is the evidence of the past; monumental objects create the important part of the cultural heritage. Selection of a method to be applied depends on many factors, which include: the objectives of inventory, the object's volume, sumptuousness of architectural design, accessibility to the object, required terms and accuracy of works. The paper presents research and experimental works, which have been performed in the course of development of architectural documentation of elements of the external facades and interiors of the Wilanów Palace Museum in Warszawa. Point clouds, acquired from terrestrial laser scanning (Z+F 5003h) and digital images taken with Nikon D3X and Hasselblad H4D cameras were used. Advantages and disadvantages of utilisation of these technologies of measurements have been analysed with consideration of the influence of the structure and reflectance of investigated monumental surfaces on the quality of generation of photogrammetric products. The geometric quality of surfaces obtained from terrestrial laser scanning data and from point clouds resulting from digital images, have been compared.

  16. Accuracy and reliability of a novel method for fusion of digital dental casts and cone beam computed tomography scans

    NARCIS (Netherlands)

    Rangel, F.A.; Maal, T.J.J.; Bronkhorst, E.M.; Breuning, K.H.; Schols, J.G.J.H.; Berge, S.J.; Kuijpers-Jagtman, A.M.

    2013-01-01

    Several methods have been proposed to integrate digital models into Cone Beam Computed Tomography scans. Since all these methods have some drawbacks such as radiation exposure, soft tissue deformation and time-consuming digital handling processes, we propose a new method to integrate digital dental

  17. The reality of virtual anthropology: Comparing digitizer and laser scan data collection methods for the quantitative assessment of the cranium.

    Science.gov (United States)

    Algee-Hewitt, Bridget F B; Wheat, Amber D

    2016-05-01

    The use of geometric morphometry to study cranial variation has steadily grown in appeal over the past decade in biological anthropology. Publication trends suggest that the most popular methods for three-dimensional data acquisition involve landmark-based coordinate data collection using a digitizer. Newer laser scan approaches are seeing increasing use, owing to the benefits that densely sampled data offer. While both of these methods have their utility, research that investigates their compatibility is lacking. The purpose of this project is to compare, quantitatively, craniometrics collected with a digitizer against data extracted from laser scans using the same individuals and laboratory conditions. Three-dimensional (x,y,z) coordinates and traditional inter-landmark distances (ILDs) were obtained with a Microscribe digitizer and 360° color models produced from NextEngine laser scans for 38 adult crania representing five cemeteries from the ADBOU skeletal collection in Denmark. Variance-based tests were performed to evaluate the disagreement between data collected with a digitizer and from laser scan models. Consideration was given to differences among landmarks by type, between ILDs calculated from landmark coordinates, and in morphology for the cemetery populations. Further, the reliability of laser scan data collection was assessed by intra-observer error tests. Researchers should be aware of the potential error associated with the use of Types II and III landmarks and the limitations on reliability imposed by object-to-scanner placement. This project reveals how laser scans can provide a valuable digital archive of cranial material that can be reasonably exploited for the "virtual" collection of coordinates and the calculation of ILDs. © 2015 Wiley Periodicals, Inc.

  18. Technique for evaluation of spatial resolution and microcalcifications in digital and scanned images of a standard breast phantom

    International Nuclear Information System (INIS)

    Santana, Priscila do C.; Gomes, Danielle S.; Oliveira, Marcio A.; Oliveira, Paulo Marcio C. de; Meira-Belo, Luiz C.; Nogueira-Tavares, Maria S.

    2011-01-01

    In this work, an automated methodology to evaluate digital and scanned images of a standard phantom (Phantom Mama) was studied. The Phantom Mama was used as an important tool to check the quality of mammographs. The scanned images were digitized using a ScanMaker 9800XL, with resolution of 900 dpi. The aim of this work is to test an automatic methodology for evaluation of spatial resolution and microcalcifications group of phantom mama images acquired with the same parameters in the same equipment. In order to analyze the images we have used the ImageJ software (in Java) which is public domain. We have used the Fast Fourier transform technique to evaluate the spatial resolution and used the ImageJ function Subtract Background and the Light Background plus Sliding Paraboloid on the evaluation of the five groups of microcalcifications on the breast phantom to assess the viability of using automated methods for both types of images. The methodology was adequate for evaluated the microcalcifications group and the spatial resolution in scanned and digital images, but the Phantom Mama doesn't provide sufficient parameters to evaluate the spatial resolution in this images. (author)

  19. Digital Processing for Modifying and Rearranging Rectilinear and Section Scan Data under Direct Observation

    Energy Technology Data Exchange (ETDEWEB)

    Kuhl, D. E.; Edwards, R. Q. [University of Pennsylvania, Philadelphia, PA (United States)

    1969-01-15

    Our digital processor for scan data is an on-site instrument that is intermediate in complexity between conventional optical processing devices and large digital computers. It is designed to provide for a wide and flexible range of secondary data operations, direct picture display on a CRT screen, and full operator control of both processing and display operations at the time of viewing. The instrument does not require the user to learn complicated programing schemes. The operator is expected to be a physician who will control the parameters of interest by punching preset buttons on a keyboard while observing changes displayed on a CRT screen. The system functions primarily as an investigative tool for studying perception of scan information and ways of making this information more meaningful. Data operations include data bounding, spatial averaging, iso-count line generation, image addition and subtraction, and several forms of quantitative read-out for analysis of regional data. The instrument is intended to serve as a central processor and reader for data from several units. Investigations with this processor have served as a source of information leading to the design of more simple processing devices suitable for wider acceptance. For example, the Mark III rectilinear and transverse section brain scanner that has evolved from this project is expected to be a practical improvement of the brain study method. This instrument is designed especially for rapid brain scanning using {sup 99m}Tc pertechnetate. It has a self-contained computer, integrated digital circuits for compactness and economy, and provision for transverse section scanning. The advantages of this system are that it provides a more thorough study using both transverse section and rectilinear modes, rapid performance, precise orientation of section and rectilinear views to the patient position, efficient transfer of information between physician and machine during studies, and economy of design

  20. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions.

    Science.gov (United States)

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin; Hwang, Hyeon-Shik

    2016-05-01

    To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken.

  1. Digitization of medical documents: an X-Windows application for fast scanning.

    Science.gov (United States)

    Muñoz, A; Salvador, C H; Gonzalez, M A; Dueñas, A

    1992-01-01

    This paper deals with digitization, using a commercial scanner, of medical documents as still images for introduction into a computer-based Information System. Document management involves storing, editing and transmission. This task has usually been approached from the perspective of the difficulties posed by radiologic images because of their indisputable qualitative and quantitative significance. However, healthcare activities require the management of many other types of documents and involve the requirements of numerous users. One key to document management will be the availability of a digitizer to deal with the greatest possible number of different types of documents. This paper describes the relevant aspects of documents and the technical specifications that digitizers must fulfill. The concept of document type is introduced as the ideal set of digitizing parameters for a given document. The use of document type parameters can drastically reduce the time the user spends in scanning sessions. Presentation is made of an application based on Unix, X-Windows and OSF/Motif, with a GPIB interface, implemented around the document type concept. Finally, the results of the evaluation of the application are presented, focusing on the user interface, as well as on the viewing of color images in an X-Windows environment and the use of lossy algorithms in the compression of medical images.

  2. Genome-Wide Scan for Adaptive Divergence and Association with Population-Specific Covariates.

    Science.gov (United States)

    Gautier, Mathieu

    2015-12-01

    In population genomics studies, accounting for the neutral covariance structure across population allele frequencies is critical to improve the robustness of genome-wide scan approaches. Elaborating on the BayEnv model, this study investigates several modeling extensions (i) to improve the estimation accuracy of the population covariance matrix and all the related measures, (ii) to identify significantly overly differentiated SNPs based on a calibration procedure of the XtX statistics, and (iii) to consider alternative covariate models for analyses of association with population-specific covariables. In particular, the auxiliary variable model allows one to deal with multiple testing issues and, providing the relative marker positions are available, to capture some linkage disequilibrium information. A comprehensive simulation study was carried out to evaluate the performances of these different models. Also, when compared in terms of power, robustness, and computational efficiency to five other state-of-the-art genome-scan methods (BayEnv2, BayScEnv, BayScan, flk, and lfmm), the proposed approaches proved highly effective. For illustration purposes, genotyping data on 18 French cattle breeds were analyzed, leading to the identification of 13 strong signatures of selection. Among these, four (surrounding the KITLG, KIT, EDN3, and ALB genes) contained SNPs strongly associated with the piebald coloration pattern while a fifth (surrounding PLAG1) could be associated to morphological differences across the populations. Finally, analysis of Pool-Seq data from 12 populations of Littorina saxatilis living in two different ecotypes illustrates how the proposed framework might help in addressing relevant ecological issues in nonmodel species. Overall, the proposed methods define a robust Bayesian framework to characterize adaptive genetic differentiation across populations. The BayPass program implementing the different models is available at http://www1.montpellier

  3. An improved three-dimensional non-scanning laser imaging system based on digital micromirror device

    Science.gov (United States)

    Xia, Wenze; Han, Shaokun; Lei, Jieyu; Zhai, Yu; Timofeev, Alexander N.

    2018-01-01

    Nowadays, there are two main methods to realize three-dimensional non-scanning laser imaging detection, which are detection method based on APD and detection method based on Streak Tube. However, the detection method based on APD possesses some disadvantages, such as small number of pixels, big pixel interval and complex supporting circuit. The detection method based on Streak Tube possesses some disadvantages, such as big volume, bad reliability and high cost. In order to resolve the above questions, this paper proposes an improved three-dimensional non-scanning laser imaging system based on Digital Micromirror Device. In this imaging system, accurate control of laser beams and compact design of imaging structure are realized by several quarter-wave plates and a polarizing beam splitter. The remapping fiber optics is used to sample the image plane of receiving optical lens, and transform the image into line light resource, which can realize the non-scanning imaging principle. The Digital Micromirror Device is used to convert laser pulses from temporal domain to spatial domain. The CCD with strong sensitivity is used to detect the final reflected laser pulses. In this paper, we also use an algorithm which is used to simulate this improved laser imaging system. In the last, the simulated imaging experiment demonstrates that this improved laser imaging system can realize three-dimensional non-scanning laser imaging detection.

  4. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

    Science.gov (United States)

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin

    2016-01-01

    Objective To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions were stored under ambient conditions, and scanned by CBCT immediately after the impressions were taken, and then at 1 hour intervals for 6 hours. After reconstructing three-dimensional digital dental models, the models were measured and the data were analyzed to determine dimensional changes according to the elapsed time. The changes within the measurement error were regarded as clinically acceptable in this study. Results All measurements showed a decreasing tendency with an increase in the elapsed time after the impressions. Although the extended-pour alginate exhibited a less decreasing tendency than the other 2 materials, there were no statistically significant differences between the materials. Changes above the measurement error occurred between the time points of 3 and 4 hours after the impressions. Conclusions The results of this study indicate that digital dental models can be obtained simply from a CBCT scan of alginate impressions without sending them to a remote laboratory. However, when the impressions are not stored under special conditions, they should be scanned immediately, or at least within 2 to 3 hours after the impressions are taken. PMID:27226958

  5. Simultaneous measurement of refractive index and thickness distributions using low-coherence digital holography and vertical scanning

    International Nuclear Information System (INIS)

    Watanabe, Kaho; Ohshima, Masashi; Nomura, Takanori

    2014-01-01

    The simultaneous measurement method of a refractive index distribution and a thickness distribution using low-coherence digital holography with a vertical scanning is proposed. The proposed method consists of a combination of digital holography and low-coherence interferometry. The introduction of a datum plane enables the measurement of both a refractive index distribution and a thickness distribution. By the optical experiment, the potential of the proposed method is confirmed. (paper)

  6. Genome scan for nonadditive heterotic trait loci reveals mainly underdominant effects in Saccharomyces cerevisiae.

    Science.gov (United States)

    Laiba, Efrat; Glikaite, Ilana; Levy, Yael; Pasternak, Zohar; Fridman, Eyal

    2016-04-01

    The overdominant model of heterosis explains the superior phenotype of hybrids by synergistic allelic interaction within heterozygous loci. To map such genetic variation in yeast, we used a population doubling time dataset of Saccharomyces cerevisiae 16 × 16 diallel and searched for major contributing heterotic trait loci (HTL). Heterosis was observed for the majority of hybrids, as they surpassed their best parent growth rate. However, most of the local heterozygous loci identified by genome scan were surprisingly underdominant, i.e., reduced growth. We speculated that in these loci adverse effects on growth resulted from incompatible allelic interactions. To test this assumption, we eliminated these allelic interactions by creating hybrids with local hemizygosity for the underdominant HTLs, as well as for control random loci. Growth of hybrids was indeed elevated for most hemizygous to HTL genes but not for control genes, hence validating the results of our genome scan. Assessing the consequences of local heterozygosity by reciprocal hemizygosity and allele replacement assays revealed the influence of genetic background on the underdominant effects of HTLs. Overall, this genome-wide study on a multi-parental hybrid population provides a strong argument against single gene overdominance as a major contributor to heterosis, and favors the dominance complementation model.

  7. The Role of Digital 3D Scanned Models in Dental Students' Self-Assessments in Preclinical Operative Dentistry.

    Science.gov (United States)

    Lee, Cliff; Kobayashi, Hiro; Lee, Samuel R; Ohyama, Hiroe

    2018-04-01

    The aim of this study was to determine how dental student self-assessment and faculty assessment of operative preparations compared for conventional visual assessment versus assessment of scanned digital 3D models. In 2016, all third-year students in the Class of 2018 (N=35) at Harvard School of Dental Medicine performed preclinical exams of Class II amalgam preparations (C2AP) and Class III composite preparations (C3CP) and completed self-assessment forms; in 2017, all third-year students in the Class of 2019 (N=34) performed the same exams. Afterwards, the prepared typodont teeth were digitally scanned. Students self-assessed their preparations digitally, and four faculty members graded the preparations conventionally and digitally. The results showed that, overall, the students assessed their preparations higher than the faculty assessments. The mean student-faculty gaps for C2AP and C3CP in the conventional assessments were 11% and 5%, respectively. The mean digital student-faculty gap for C2AP and C3CP were 8% and 2%, respectively. In the conventional assessments, preclinical performance was negatively correlated with the student-faculty gap (r=-0.47, pStudents in the bottom quartile significantly improved their self-assessment accuracy using digital self-assessments over conventional assessments (C2AP 10% vs. 17% and C3CP 3% vs. 10%, respectively). These results suggest that digital assessments offered a significant learning opportunity for students to critically self-assess themselves in operative preclinical dentistry. The lower performing students benefitted the most, improving their assessment ability to the level of the rest of the class.

  8. Dimensional accuracy of digital dental models from cone-beam computed tomography scans of alginate impressions according to time elapsed after the impressions.

    Science.gov (United States)

    Lee, Sang-Mi; Hou, Yanan; Cho, Jin-Hyoung; Hwang, Hyeon-Shik

    2016-02-01

    Our objective was to investigate the dimensional accuracy of digital dental models obtained from the cone-beam computed tomography (CBCT) scans of alginate impressions according to the time elapsed after the impressions were taken. Alginate impressions were obtained of 20 adults using 2 alginate materials: Alginoplast (Heraeus Kulzer, Hanau, Germany) and Cavex (Cavex Holland, Haarlem, The Netherlands). These impressions were stored in wet conditions and scanned by CBCT immediately after impression-taking and after storage times of 12, 24, 36, 48, 60, and 72 hours. After reconstruction of the 3-dimensional digital dental models, the models were measured, and the data were analyzed to determine the dimensional changes according to the time elapsed. The changes within the measurement error were regarded as clinically acceptable in this study. The measurement errors ranged from 0.27 to 0.29 mm in the digital dental models obtained from CBCT scans of the alginate impressions. All measurements showed decreasing accuracy with greater elapsed time after the impressions were taken. Changes above the measurement error occurred at 24 and 36 hours for Cavex and Alginoplast, respectively. Digital dental models can be obtained from CBCT scans of alginate impressions without sending them to a remote laboratory. However, the impressions need to be scanned within 24 hours; otherwise, dimensional changes lead to errors that exceed the error of measurement. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  9. Combined genome scans for body stature in 6,602 European twins

    DEFF Research Database (Denmark)

    Perola, Markus; Sammalisto, Sampo; Hiekkalinna, Tero

    2007-01-01

    combined and related to the sequence positions using software developed by us, which is publicly available (https://apps.bioinfo.helsinki.fi/software/cartographer.aspx). Variance component linkage analysis was performed with age, sex, and country of origin as covariates. The covariate adjusted heritability....... Several cohorts contributed to the identified loci, suggesting an evolutionarily old genetic variant having effects on stature in European-based populations. To facilitate the genetic studies of stature we have also set up a website that lists all stature genome scans published and their most significant...

  10. A scan statistic to extract causal gene clusters from case-control genome-wide rare CNV data

    Directory of Open Access Journals (Sweden)

    Scherer Stephen W

    2011-05-01

    Full Text Available Abstract Background Several statistical tests have been developed for analyzing genome-wide association data by incorporating gene pathway information in terms of gene sets. Using these methods, hundreds of gene sets are typically tested, and the tested gene sets often overlap. This overlapping greatly increases the probability of generating false positives, and the results obtained are difficult to interpret, particularly when many gene sets show statistical significance. Results We propose a flexible statistical framework to circumvent these problems. Inspired by spatial scan statistics for detecting clustering of disease occurrence in the field of epidemiology, we developed a scan statistic to extract disease-associated gene clusters from a whole gene pathway. Extracting one or a few significant gene clusters from a global pathway limits the overall false positive probability, which results in increased statistical power, and facilitates the interpretation of test results. In the present study, we applied our method to genome-wide association data for rare copy-number variations, which have been strongly implicated in common diseases. Application of our method to a simulated dataset demonstrated the high accuracy of this method in detecting disease-associated gene clusters in a whole gene pathway. Conclusions The scan statistic approach proposed here shows a high level of accuracy in detecting gene clusters in a whole gene pathway. This study has provided a sound statistical framework for analyzing genome-wide rare CNV data by incorporating topological information on the gene pathway.

  11. Candidate genes revealed by a genome scan for mosquito resistance to a bacterial insecticide: sequence and gene expression variations

    Directory of Open Access Journals (Sweden)

    David Jean-Philippe

    2009-11-01

    Full Text Available Abstract Background Genome scans are becoming an increasingly popular approach to study the genetic basis of adaptation and speciation, but on their own, they are often helpless at identifying the specific gene(s or mutation(s targeted by selection. This shortcoming is hopefully bound to disappear in the near future, thanks to the wealth of new genomic resources that are currently being developed for many species. In this article, we provide a foretaste of this exciting new era by conducting a genome scan in the mosquito Aedes aegypti with the aim to look for candidate genes involved in resistance to Bacillus thuringiensis subsp. israelensis (Bti insecticidal toxins. Results The genome of a Bti-resistant and a Bti-susceptible strains was surveyed using about 500 MITE-based molecular markers, and the loci showing the highest inter-strain genetic differentiation were sequenced and mapped on the Aedes aegypti genome sequence. Several good candidate genes for Bti-resistance were identified in the vicinity of these highly differentiated markers. Two of them, coding for a cadherin and a leucine aminopeptidase, were further examined at the sequence and gene expression levels. In the resistant strain, the cadherin gene displayed patterns of nucleotide polymorphisms consistent with the action of positive selection (e.g. an excess of high compared to intermediate frequency mutations, as well as a significant under-expression compared to the susceptible strain. Conclusion Both sequence and gene expression analyses agree to suggest a role for positive selection in the evolution of this cadherin gene in the resistant strain. However, it is unlikely that resistance to Bti is conferred by this gene alone, and further investigation will be needed to characterize other genes significantly associated with Bti resistance in Ae. aegypti. Beyond these results, this article illustrates how genome scans can build on the body of new genomic information (here, full

  12. Influence of scanning system and dentist's level of training in the accuracy of digital impressions

    Science.gov (United States)

    Hategan, Simona; Gabor, Alin; Zaharia, Cristian; Sinescu, Cosmin; Negrutiu, Meda Lavinia; Jivanescu, Anca

    2016-03-01

    Background: The principal aim of our study was to evaluate digital impressions, taken with spray powder and powderfree scan systems, in order to determine the influence of the dentist's commitment to training as a critical factor regarding quality. Material and method: Two digital intraoral impression systems from the same manufacture (Sirona) : Apollo DI and CEREC Omnicam, were used to scan 16 crown preparations on teeth on a typodont maxillary model. Because an Apollo Di intraoral camera is a powder system, an adhesive was applied before using the powder spray. Three groups were used to scan the crown preparations in order to determine coating thickness homogeneity. One group consisted of senior year dental students, a second consisted of prosthodontics residents, and the third consisted of prosthodontics specialists. The same procedure was applied with a CEREC Omnicam intraoral camera, which is a powder-free system. By using the two systems software parameters we were able to determine the scanning precision. Results: Homogeneity scores for Apollo Di regarding the spray layer was significantly thinner for all dental surfaces in the first group, while the second group had thinner coatings for buccal and distal surfaces. For the third group, the crown preparations were coated more homogeneously than the first two groups. The powder-free system CEREC Omnicam can, to a degree, mask the lack of experience in direct optical impressions by avoiding the poor quality coating, which can lead to defective marginal adaptation of definitive restoration. Conclusions: The dentist's lack of experience can be mitigated, and partially avoided, by using powder-free systems. At the same time, the dentist can give more time towards learning how to integrate computerized fabricated restoration into the practice. The commitment to training is a critical factor in the successful integration of the technology. In addition, scanning marginal preparation details needs time in order to

  13. A genome scan for positive selection in thoroughbred horses.

    Science.gov (United States)

    Gu, Jingjing; Orr, Nick; Park, Stephen D; Katz, Lisa M; Sulimova, Galina; MacHugh, David E; Hill, Emmeline W

    2009-06-02

    Thoroughbred horses have been selected for exceptional racing performance resulting in system-wide structural and functional adaptations contributing to elite athletic phenotypes. Because selection has been recent and intense in a closed population that stems from a small number of founder animals Thoroughbreds represent a unique population within which to identify genomic contributions to exercise-related traits. Employing a population genetics-based hitchhiking mapping approach we performed a genome scan using 394 autosomal and X chromosome microsatellite loci and identified positively selected loci in the extreme tail-ends of the empirical distributions for (1) deviations from expected heterozygosity (Ewens-Watterson test) in Thoroughbred (n = 112) and (2) global differentiation among four geographically diverse horse populations (F(ST)). We found positively selected genomic regions in Thoroughbred enriched for phosphoinositide-mediated signalling (3.2-fold enrichment; PThoroughbred athletic phenotype. We report for the first time candidate athletic-performance genes within regions targeted by selection in Thoroughbred horses that are principally responsible for fatty acid oxidation, increased insulin sensitivity and muscle strength: ACSS1 (acyl-CoA synthetase short-chain family member 1), ACTA1 (actin, alpha 1, skeletal muscle), ACTN2 (actinin, alpha 2), ADHFE1 (alcohol dehydrogenase, iron containing, 1), MTFR1 (mitochondrial fission regulator 1), PDK4 (pyruvate dehydrogenase kinase, isozyme 4) and TNC (tenascin C). Understanding the genetic basis for exercise adaptation will be crucial for the identification of genes within the complex molecular networks underlying obesity and its consequential pathologies, such as type 2 diabetes. Therefore, we propose Thoroughbred as a novel in vivo large animal model for understanding molecular protection against metabolic disease.

  14. A digital transducer and digital microphone using an optical technique

    Science.gov (United States)

    Ghelmansarai, F. A.

    1996-09-01

    A transducer is devised to measure pressure, displacements or angles by optical means. This transducer delivers a digital output without relying on interferometry techniques or analogue-to-digital converters. This device is based on an optical scanner and an optical detector. An inter-digital photoconductive detector (IDPC) is employed that delivers a series of pulses, whose number depends on the scan length. A pre-objective scanning configuration is used that allows for the possibility of a flat image plane. The optical scanner provides scanning of IDPC and the generated scan length is proportional to the measurand.

  15. A CdZnTe slot-scanned detector for digital mammography

    International Nuclear Information System (INIS)

    Mainprize, James G.; Ford, Nancy L.; Yin Shi; Gordon, Eli E.; Hamilton, William J.; Tuemer, Tuemay O.; Yaffe, Martin J.

    2002-01-01

    A new high-resolution detector has been developed for use in a slot-scanned digital mammography system. The detector is a hybrid device that consists of a CCD operating in time-delay integration mode that is bonded to a 150-μm-thick CdZnTe photoconductor array. The CCD was designed with a detector element pitch of 50 μm. Two devices were evaluated with differing crystalline quality. Incomplete charge collection was a source of reduction in DQE. This occurs in both devices due to characteristically low mobility-lifetime products for CdZnTe, with the greatest losses demonstrated by the multicrystalline sample. The mobility-lifetime products for the multicrystalline device were found to be 2.4x10 -4 and 4.0x10 -7 cm 2 /V for electrons and holes, respectively. The device constructed with higher quality single crystal CdZnTe demonstrated mobility-lifetime products of 1.0x10 -4 and 4.4x10 -6 cm 2 /V for electrons and holes. The MTF and DQE for the device were measured at several exposures and results were compared to predictions from a linear systems model of signal and noise propagation. The MTF at a spatial frequency of 10 mm -1 exceeded 0.18 and 0.56 along the scan and slot directions, respectively. Scanning motion and CCD design limited the resolution along the scan direction. For an x-ray beam from a tungsten target tube with 40 μm molybdenum filtration operated at 26 kV, the single crystal device demonstrated a DQE(0) of 0.70±0.02 at 7.1x10 -6 C/kg (27 mR) exposure to the detector, despite its relatively poor charge collection efficiency

  16. Feasibility study for image reconstruction in circular digital tomosynthesis (CDTS) from limited-scan angle data based on compressed-sensing theory

    Energy Technology Data Exchange (ETDEWEB)

    Park, Yeonok; Je, Uikyu; Cho, Hyosung, E-mail: hscho1@yonsei.ac.kr; Hong, Daeki; Park, Chulkyu; Cho, Heemoon; Choi, Sungil; Woo, Taeho

    2015-03-21

    In this work, we performed a feasibility study for image reconstruction in a circular digital tomosynthesis (CDTS) from limited-scan angle data based on compressed-sensing (CS) theory. Here, the X-ray source moves along an arc within a limited-scan angle (≤ 180°) on a circular path set perpendicularly to the axial direction during the image acquisition. This geometry, compared to full-angle (360°) scan geometry, allows imaging system to be designed more compactly and gives better tomographic quality than conventional linear digital tomosynthesis (DTS). We implemented an efficient CS-based reconstruction algorithm for the proposed geometry and performed systematic simulations to investigate the image characteristics. We successfully reconstructed CDTS images with incomplete projections acquired at several selected limited-scan angles of 45°, 90°, 135°, and 180° for a given tomographic angle of 80° and evaluated the reconstruction quality. Our simulation results indicate that the proposed method can provide superior tomographic quality for axial view and even for the other views (i.e., sagittal and coronal), as in computed tomography, to conventional DTS. - Highlights: • Image reconstruction is done in circular digital tomosynthesis (CDTS). • The designed geometry allows imaging system to be the better image. • An efficient compressed-sensing (CS)-based reconstruction algorithm is performed. • Proposed method can provide superior tomographic quality for the axial view.

  17. Genome-wide association scan for variants associated with early-onset prostate cancer.

    Directory of Open Access Journals (Sweden)

    Ethan M Lange

    Full Text Available Prostate cancer is the most common non-skin cancer and the second leading cause of cancer related mortality for men in the United States. There is strong empirical and epidemiological evidence supporting a stronger role of genetics in early-onset prostate cancer. We performed a genome-wide association scan for early-onset prostate cancer. Novel aspects of this study include the focus on early-onset disease (defined as men with prostate cancer diagnosed before age 56 years and use of publically available control genotype data from previous genome-wide association studies. We found genome-wide significant (p<5×10(-8 evidence for variants at 8q24 and 11p15 and strong supportive evidence for a number of previously reported loci. We found little evidence for individual or systematic inflated association findings resulting from using public controls, demonstrating the utility of using public control data in large-scale genetic association studies of common variants. Taken together, these results demonstrate the importance of established common genetic variants for early-onset prostate cancer and the power of including early-onset prostate cancer cases in genetic association studies.

  18. APPLICATION OF 3D DIGITAL SCANNING AND CAD/CAM SYSTEMS FOR ZIRCONIA INDIRECT RESTORATIONS

    Directory of Open Access Journals (Sweden)

    Mariela Tsanova

    2016-09-01

    Full Text Available Object: To study the CAD/CAM systems’ possibilities for manufacturing Zirconia indirect restorations for restoring vital, vastly devastated teeth. Material and methods: Five patients with vital, heavily destroyed molars were included in the clinical study. The teeth were prepared according to requirements for Zirconia restorations. The impressions were taken with 3D intraoral scanner. The acquired data is transmitted electronically for designing the future restoration by the CAD software. After designing, the restoration is milled by the CAM module and sintered, according to a specially projected programme in accordance with the manufacturing demands. After clinical check-up, the restorations are glazed, air-blasted and cemented. Results: Setting up an individual protocol for working with CAD/CAM systems for restoring vital, severely devastated teeth with Zirconia indirect restorations. A research is made on 3D digital scanning, occlusal and proximal modeling, virtual articulation, analyzing the incline of the cavity walls, the thickness of the restoration and the possibilities for restoring the anatomy of the tooth according to patient’s individual characteristics of the teeth’s arch. Conclusion: The scanning and design process should be evaluated with the same quality control as when using traditional methods. The CAD software requires excellent preparation of the tooth cavity and digital scanning. This is the reason why these systems require a thorough understanding of CAD/CAM calibration and parameters of the product to be clinically acceptable. Once understood, CAD/CAM dentistry can create detailed and accurate restorations that function and perform with great success and longevity.

  19. AFLP genome scanning reveals divergent selection in natural populations of Liriodendron chinense (Magnoliaceae along a latitudinal transect

    Directory of Open Access Journals (Sweden)

    Aihong eYang

    2016-05-01

    Full Text Available Understanding adaptive genetic variation and its relation to environmental factors are important for understanding how plants adapt to climate change and for managing genetic resources. Genome scans for the loci exhibiting either notably high or low levels of population differentiation (outlier loci provide one means of identifying genomic regions possibly associated with convergent or divergent selection. In this study, we combined AFLP genome scan and environmental association analysis to test for signals of natural selection in natural populations of Liriodendron chinense (Chinese Tulip Tree; Magnoliaceae along a latitudinal transect. We genotyped 276 individuals from 11 populations of L. chinense using 987 AFLP markers. Two complementary methods (Dfdist and BayeScan and association analysis between AFLP loci and climate factors were applied to detect outlier loci. Our analyses recovered both neutral and potentially adaptive genetic differentiation among populations of L. chinense. We found moderate genetic diversity within populations and high genetic differentiation among populations with reduced genetic diversity towards the periphery of the species ranges. Nine AFLP marker loci showed evidence of being outliers for population differentiation for both detection methods. Of these, six were strongly associated with at least one climate factor. Temperature, precipitation and radiation were found to be three important factors influencing local adaptation of L. chinense. The outlier AFLP loci are likely not the target of natural selection, but the neighboring genes of these loci might be involved in local adaptation. Hence, these candidates should be validated by further studies.

  20. Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions

    NARCIS (Netherlands)

    Wiranto, Matthew G.; Engelbrecht, W. Petrie; Nolthenius, Heleen E. Tutein; van der Meer, W. Joerd; Ren, Yijin

    INTRODUCTION: Digital 3-dimensional models are widely used for orthodontic diagnosis. The aim of this study was to assess the validity, reliability, and reproducibility of digital models obtained from the Lava Chairside Oral scanner (3M ESPE, Seefeld, Germany) and cone-beam computed tomography scans

  1. Digital X-Radiography Scanning Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Generates digital X-radiographic images of sediment cores that portray density variations, sediment stratigraphy, bioturbation, and inclusions.DESCRIPTION:...

  2. The digital Emily project: achieving a photorealistic digital actor.

    Science.gov (United States)

    Alexander, Oleg; Rogers, Mike; Lambeth, William; Chiang, Jen-Yuan; Ma, Wan-Chun; Wang, Chuan-Chang; Debevec, Paul

    2010-01-01

    The Digital Emily Project uses advanced face scanning, character rigging, performance capture, and compositing to achieve one of the world's first photorealistic digital facial performances. The project scanned the geometry and reflectance of actress Emily O'Brien's face in 33 poses, showing different emotions, gaze directions, and lip formations in a light stage. These high-resolution scans-accurate to skin pores and fine wrinkles-became the basis for building a blendshape-based facial-animation rig whose expressions closely matched the scans. The blendshape rig drove displacement maps to add dynamic surface detail. A video-based facial animation system animated the face according to the performance in a reference video, and the digital face was tracked onto the video's motion and rendered under the same illumination. The result was a realistic 3D digital facial performance credited as one of the first to cross the "uncanny valley" between animated and fully human performances.

  3. Genome-wide scan of healthy human connectome discovers SPON1 gene variant influencing dementia severity

    Science.gov (United States)

    Jahanshad, Neda; Rajagopalan, Priya; Hua, Xue; Hibar, Derrek P.; Nir, Talia M.; Toga, Arthur W.; Jack, Clifford R.; Saykin, Andrew J.; Green, Robert C.; Weiner, Michael W.; Medland, Sarah E.; Montgomery, Grant W.; Hansell, Narelle K.; McMahon, Katie L.; de Zubicaray, Greig I.; Martin, Nicholas G.; Wright, Margaret J.; Thompson, Paul M.; Weiner, Michael; Aisen, Paul; Weiner, Michael; Aisen, Paul; Petersen, Ronald; Jack, Clifford R.; Jagust, William; Trojanowski, John Q.; Toga, Arthur W.; Beckett, Laurel; Green, Robert C.; Saykin, Andrew J.; Morris, John; Liu, Enchi; Green, Robert C.; Montine, Tom; Petersen, Ronald; Aisen, Paul; Gamst, Anthony; Thomas, Ronald G.; Donohue, Michael; Walter, Sarah; Gessert, Devon; Sather, Tamie; Beckett, Laurel; Harvey, Danielle; Gamst, Anthony; Donohue, Michael; Kornak, John; Jack, Clifford R.; Dale, Anders; Bernstein, Matthew; Felmlee, Joel; Fox, Nick; Thompson, Paul; Schuff, Norbert; Alexander, Gene; DeCarli, Charles; Jagust, William; Bandy, Dan; Koeppe, Robert A.; Foster, Norm; Reiman, Eric M.; Chen, Kewei; Mathis, Chet; Morris, John; Cairns, Nigel J.; Taylor-Reinwald, Lisa; Trojanowki, J.Q.; Shaw, Les; Lee, Virginia M.Y.; Korecka, Magdalena; Toga, Arthur W.; Crawford, Karen; Neu, Scott; Saykin, Andrew J.; Foroud, Tatiana M.; Potkin, Steven; Shen, Li; Khachaturian, Zaven; Frank, Richard; Snyder, Peter J.; Molchan, Susan; Kaye, Jeffrey; Quinn, Joseph; Lind, Betty; Dolen, Sara; Schneider, Lon S.; Pawluczyk, Sonia; Spann, Bryan M.; Brewer, James; Vanderswag, Helen; Heidebrink, Judith L.; Lord, Joanne L.; Petersen, Ronald; Johnson, Kris; Doody, Rachelle S.; Villanueva-Meyer, Javier; Chowdhury, Munir; Stern, Yaakov; Honig, Lawrence S.; Bell, Karen L.; Morris, John C.; Ances, Beau; Carroll, Maria; Leon, Sue; Mintun, Mark A.; Schneider, Stacy; Marson, Daniel; Griffith, Randall; Clark, David; Grossman, Hillel; Mitsis, Effie; Romirowsky, Aliza; deToledo-Morrell, Leyla; Shah, Raj C.; Duara, Ranjan; Varon, Daniel; Roberts, Peggy; Albert, Marilyn; Onyike, Chiadi; Kielb, Stephanie; Rusinek, Henry; de Leon, Mony J.; Glodzik, Lidia; De Santi, Susan; Doraiswamy, P. Murali; Petrella, Jeffrey R.; Coleman, R. Edward; Arnold, Steven E.; Karlawish, Jason H.; Wolk, David; Smith, Charles D.; Jicha, Greg; Hardy, Peter; Lopez, Oscar L.; Oakley, MaryAnn; Simpson, Donna M.; Porsteinsson, Anton P.; Goldstein, Bonnie S.; Martin, Kim; Makino, Kelly M.; Ismail, M. Saleem; Brand, Connie; Mulnard, Ruth A.; Thai, Gaby; Mc-Adams-Ortiz, Catherine; Womack, Kyle; Mathews, Dana; Quiceno, Mary; Diaz-Arrastia, Ramon; King, Richard; Weiner, Myron; Martin-Cook, Kristen; DeVous, Michael; Levey, Allan I.; Lah, James J.; Cellar, Janet S.; Burns, Jeffrey M.; Anderson, Heather S.; Swerdlow, Russell H.; Apostolova, Liana; Lu, Po H.; Bartzokis, George; Silverman, Daniel H.S.; Graff-Radford, Neill R.; Parfitt, Francine; Johnson, Heather; Farlow, Martin R.; Hake, Ann Marie; Matthews, Brandy R.; Herring, Scott; van Dyck, Christopher H.; Carson, Richard E.; MacAvoy, Martha G.; Chertkow, Howard; Bergman, Howard; Hosein, Chris; Black, Sandra; Stefanovic, Bojana; Caldwell, Curtis; Hsiung, Ging-Yuek Robin; Feldman, Howard; Mudge, Benita; Assaly, Michele; Kertesz, Andrew; Rogers, John; Trost, Dick; Bernick, Charles; Munic, Donna; Kerwin, Diana; Mesulam, Marek-Marsel; Lipowski, Kristina; Wu, Chuang-Kuo; Johnson, Nancy; Sadowsky, Carl; Martinez, Walter; Villena, Teresa; Turner, Raymond Scott; Johnson, Kathleen; Reynolds, Brigid; Sperling, Reisa A.; Johnson, Keith A.; Marshall, Gad; Frey, Meghan; Yesavage, Jerome; Taylor, Joy L.; Lane, Barton; Rosen, Allyson; Tinklenberg, Jared; Sabbagh, Marwan; Belden, Christine; Jacobson, Sandra; Kowall, Neil; Killiany, Ronald; Budson, Andrew E.; Norbash, Alexander; Johnson, Patricia Lynn; Obisesan, Thomas O.; Wolday, Saba; Bwayo, Salome K.; Lerner, Alan; Hudson, Leon; Ogrocki, Paula; Fletcher, Evan; Carmichael, Owen; Olichney, John; DeCarli, Charles; Kittur, Smita; Borrie, Michael; Lee, T.-Y.; Bartha, Rob; Johnson, Sterling; Asthana, Sanjay; Carlsson, Cynthia M.; Potkin, Steven G.; Preda, Adrian; Nguyen, Dana; Tariot, Pierre; Fleisher, Adam; Reeder, Stephanie; Bates, Vernice; Capote, Horacio; Rainka, Michelle; Scharre, Douglas W.; Kataki, Maria; Zimmerman, Earl A.; Celmins, Dzintra; Brown, Alice D.; Pearlson, Godfrey D.; Blank, Karen; Anderson, Karen; Saykin, Andrew J.; Santulli, Robert B.; Schwartz, Eben S.; Sink, Kaycee M.; Williamson, Jeff D.; Garg, Pradeep; Watkins, Franklin; Ott, Brian R.; Querfurth, Henry; Tremont, Geoffrey; Salloway, Stephen; Malloy, Paul; Correia, Stephen; Rosen, Howard J.; Miller, Bruce L.; Mintzer, Jacobo; Longmire, Crystal Flynn; Spicer, Kenneth; Finger, Elizabeth; Rachinsky, Irina; Rogers, John; Kertesz, Andrew; Drost, Dick

    2013-01-01

    Aberrant connectivity is implicated in many neurological and psychiatric disorders, including Alzheimer’s disease and schizophrenia. However, other than a few disease-associated candidate genes, we know little about the degree to which genetics play a role in the brain networks; we know even less about specific genes that influence brain connections. Twin and family-based studies can generate estimates of overall genetic influences on a trait, but genome-wide association scans (GWASs) can screen the genome for specific variants influencing the brain or risk for disease. To identify the heritability of various brain connections, we scanned healthy young adult twins with high-field, high-angular resolution diffusion MRI. We adapted GWASs to screen the brain’s connectivity pattern, allowing us to discover genetic variants that affect the human brain’s wiring. The association of connectivity with the SPON1 variant at rs2618516 on chromosome 11 (11p15.2) reached connectome-wide, genome-wide significance after stringent statistical corrections were enforced, and it was replicated in an independent subsample. rs2618516 was shown to affect brain structure in an elderly population with varying degrees of dementia. Older people who carried the connectivity variant had significantly milder clinical dementia scores and lower risk of Alzheimer’s disease. As a posthoc analysis, we conducted GWASs on several organizational and topological network measures derived from the matrices to discover variants in and around genes associated with autism (MACROD2), development (NEDD4), and mental retardation (UBE2A) significantly associated with connectivity. Connectome-wide, genome-wide screening offers substantial promise to discover genes affecting brain connectivity and risk for brain diseases. PMID:23471985

  4. Digital radiography

    International Nuclear Information System (INIS)

    Brody, W.R.

    1984-01-01

    Digital Radiography begins with an orderly introduction to the fundamental concepts of digital imaging. The entire X-ray digital imagining system is described, from an overall characterization of image quality to specific components required for a digital radiographic system. Because subtraction is central to digital radiographic systems, the author details the use of various subtraction methods for image enhancement. Complex concepts are illustrated with numerous examples and presented in terms that can readily be understood by physicians without an advanced mathematics background. The second part of the book discusses implementations and applications of digital imagining systems based on area and scanned detector technologies. This section includes thorough coverage of digital fluoroscopy, scanned projection radiography, and film-based digital imaging systems, and features a state-of-the-art synopsis of the applications of digital subtraction angiography. The book concludes with a timely assessment of anticipated technological advances

  5. Rotational scanning and multiple-spot focusing through a multimode fiber based on digital optical phase conjugation

    Science.gov (United States)

    Ma, Chaojie; Di, Jianglei; Li, Ying; Xiao, Fajun; Zhang, Jiwei; Liu, Kaihui; Bai, Xuedong; Zhao, Jianlin

    2018-06-01

    We demonstrate, for the first time, the rotational memory effect of a multimode fiber (MMF) based on digital optical phase conjugation (DOPC) to achieve multiple-spot focusing. An implementation interferometer is used to address the challenging alignments in DOPC. By rotating the acquired phase conjugate pattern, rotational scanning through a MMF could be achieved by recording a single off-axis hologram. The generation of two focal spots through a MMF is also demonstrated by combining the rotational memory effect with the superposition principle. The results may be useful for ultrafast scanning imaging and optical manipulation of multiple objects through a MMF.

  6. Absolute determination of single-stranded and self-complementary adeno-associated viral vector genome titers by droplet digital PCR.

    Science.gov (United States)

    Lock, Martin; Alvira, Mauricio R; Chen, Shu-Jen; Wilson, James M

    2014-04-01

    Accurate titration of adeno-associated viral (AAV) vector genome copies is critical for ensuring correct and reproducible dosing in both preclinical and clinical settings. Quantitative PCR (qPCR) is the current method of choice for titrating AAV genomes because of the simplicity, accuracy, and robustness of the assay. However, issues with qPCR-based determination of self-complementary AAV vector genome titers, due to primer-probe exclusion through genome self-annealing or through packaging of prematurely terminated defective interfering (DI) genomes, have been reported. Alternative qPCR, gel-based, or Southern blotting titering methods have been designed to overcome these issues but may represent a backward step from standard qPCR methods in terms of simplicity, robustness, and precision. Droplet digital PCR (ddPCR) is a new PCR technique that directly quantifies DNA copies with an unparalleled degree of precision and without the need for a standard curve or for a high degree of amplification efficiency; all properties that lend themselves to the accurate quantification of both single-stranded and self-complementary AAV genomes. Here we compare a ddPCR-based AAV genome titer assay with a standard and an optimized qPCR assay for the titration of both single-stranded and self-complementary AAV genomes. We demonstrate absolute quantification of single-stranded AAV vector genomes by ddPCR with up to 4-fold increases in titer over a standard qPCR titration but with equivalent readout to an optimized qPCR assay. In the case of self-complementary vectors, ddPCR titers were on average 5-, 1.9-, and 2.3-fold higher than those determined by standard qPCR, optimized qPCR, and agarose gel assays, respectively. Droplet digital PCR-based genome titering was superior to qPCR in terms of both intra- and interassay precision and is more resistant to PCR inhibitors, a desirable feature for in-process monitoring of early-stage vector production and for vector genome biodistribution

  7. Digital Dentistry — Digital Impression and CAD/CAM System Applications

    Directory of Open Access Journals (Sweden)

    Gabor Alin-Gabriel

    2017-03-01

    Full Text Available Digital imprint and computer-aided design/computer-aided manufacture (CAD/CAM systems offer several benefits compared to traditional techniques. The use of a CAD/CAM system to scan preparations and generate restorations in-office, removes a second appointment for the patient. The existence of precision benefits in using complete systems and chairside scanning systems, has been proven. CAD/CAM restorations have a good longevity and meet the accepted clinical parameters. New digital impression methods are presently accessible, and before long, the long-awaited goal of sparing patients of one the most unpleasant practices in clinical dentistry, acquiring dental impressions, will be exchanged by intraoral digital scanning. CAD/CAM systems existing nowadays, can feed data through accurate digital scans created from plaster models, straight to manufacturing systems that can shape ceramic or resin restorations with no requirement of a physical copy of the prepared, adjacent, and antagonist teeth.

  8. Automated detection of analyzable metaphase chromosome cells depicted on scanned digital microscopic images

    Science.gov (United States)

    Qiu, Yuchen; Wang, Xingwei; Chen, Xiaodong; Li, Yuhua; Liu, Hong; Li, Shibo; Zheng, Bin

    2010-02-01

    Visually searching for analyzable metaphase chromosome cells under microscopes is quite time-consuming and difficult. To improve detection efficiency, consistency, and diagnostic accuracy, an automated microscopic image scanning system was developed and tested to directly acquire digital images with sufficient spatial resolution for clinical diagnosis. A computer-aided detection (CAD) scheme was also developed and integrated into the image scanning system to search for and detect the regions of interest (ROI) that contain analyzable metaphase chromosome cells in the large volume of scanned images acquired from one specimen. Thus, the cytogeneticists only need to observe and interpret the limited number of ROIs. In this study, the high-resolution microscopic image scanning and CAD performance was investigated and evaluated using nine sets of images scanned from either bone marrow (three) or blood (six) specimens for diagnosis of leukemia. The automated CAD-selection results were compared with the visual selection. In the experiment, the cytogeneticists first visually searched for the analyzable metaphase chromosome cells from specimens under microscopes. The specimens were also automated scanned and followed by applying the CAD scheme to detect and save ROIs containing analyzable cells while deleting the others. The automated selected ROIs were then examined by a panel of three cytogeneticists. From the scanned images, CAD selected more analyzable cells than initially visual examinations of the cytogeneticists in both blood and bone marrow specimens. In general, CAD had higher performance in analyzing blood specimens. Even in three bone marrow specimens, CAD selected 50, 22, 9 ROIs, respectively. Except matching with the initially visual selection of 9, 7, and 5 analyzable cells in these three specimens, the cytogeneticists also selected 41, 15 and 4 new analyzable cells, which were missed in initially visual searching. This experiment showed the feasibility of

  9. Quantitative linkage genome scan for atopy in a large collection of Caucasian families

    DEFF Research Database (Denmark)

    Webb, BT; van den Oord, E; Akkari, A

    2007-01-01

    adulthood, asthma is frequently associated also with quantitative measures of atopy. Genome wide quantitative multipoint linkage analysis was conducted for serum IgE levels and percentage of positive skin prick test (SPT(per)) using three large groups of families originally ascertained for asthma....... In this report, 438 and 429 asthma families were informative for linkage using IgE and SPT(per) which represents 690 independent families. Suggestive linkage (LOD >/= 2) was found on chromosomes 1, 3, and 8q with maximum LODs of 2.34 (IgE), 2.03 (SPT(per)), and 2.25 (IgE) near markers D1S1653, D3S2322-D3S1764...... represents one of the biggest genome scans so far reported for asthma related phenotypes. This study also demonstrates the utility of increased sample sizes and quantitative phenotypes in linkage analysis of complex disorders....

  10. Fundamental imaging characteristics of a slot-scan digital chest radiographic system

    International Nuclear Information System (INIS)

    Samei, Ehsan; Saunders, Robert S.; Lo, Joseph Y.; Dobbins, James T. III; Jesneck, Jonathan L.; Floyd, Carey E.; Ravin, Carl E.

    2004-01-01

    Our purpose in this study was to evaluate the fundamental image quality characteristics of a new slot-scan digital chest radiography system (ThoraScan, Delft Imaging Systems/Nucletron, Veenendaal, The Netherlands). The linearity of the system was measured over a wide exposure range at 90, 117, and 140 kVp with added Al filtration. System uniformity and reproducibility were established with an analysis of images from repeated exposures. The modulation transfer function (MTF) was evaluated using an established edge method. The noise power spectrum (NPS) and the detective quantum efficiency (DQE) of the system were evaluated at the three kilo-voltages over a range of exposures. Scatter fraction (SF) measurements were made using a posterior beam stop method and a geometrical chest phantom. The system demonstrated excellent linearity, but some structured nonuniformities. The 0.1 MTF values occurred between 3.3-3.5 mm -1 . The DQE(0.15) and DQE(2.5) were 0.21 and 0.07 at 90 kVp, 0.18 and 0.05 at 117 kVp, and 0.16 and 0.03 at 140 kVp, respectively. The system exhibited remarkably lower SFs compared to conventional full-field systems with anti-scatter grid, measuring 0.13 in the lungs and 0.43 in the mediastinum. The findings indicated that the slot-scan design provides marked scatter reduction leading to high effective DQE (DQE eff ) of the system and reduced patient dose required to achieve high image quality

  11. Single-Cell-Based Platform for Copy Number Variation Profiling through Digital Counting of Amplified Genomic DNA Fragments.

    Science.gov (United States)

    Li, Chunmei; Yu, Zhilong; Fu, Yusi; Pang, Yuhong; Huang, Yanyi

    2017-04-26

    We develop a novel single-cell-based platform through digital counting of amplified genomic DNA fragments, named multifraction amplification (mfA), to detect the copy number variations (CNVs) in a single cell. Amplification is required to acquire genomic information from a single cell, while introducing unavoidable bias. Unlike prevalent methods that directly infer CNV profiles from the pattern of sequencing depth, our mfA platform denatures and separates the DNA molecules from a single cell into multiple fractions of a reaction mix before amplification. By examining the sequencing result of each fraction for a specific fragment and applying a segment-merge maximum likelihood algorithm to the calculation of copy number, we digitize the sequencing-depth-based CNV identification and thus provide a method that is less sensitive to the amplification bias. In this paper, we demonstrate a mfA platform through multiple displacement amplification (MDA) chemistry. When performing the mfA platform, the noise of MDA is reduced; therefore, the resolution of single-cell CNV identification can be improved to 100 kb. We can also determine the genomic region free of allelic drop-out with mfA platform, which is impossible for conventional single-cell amplification methods.

  12. Film-screen digital radiography

    International Nuclear Information System (INIS)

    Schwenker, R.P.; Eger, H.

    1985-01-01

    The excellent performance of the digital film-screen system as a receptor for projection radiographic data is discussed. An experimental system for obtaining high quality digital radiographic data by laser scanning radiographic films is described. This system is being used to evaluate the clinical utility of various digital image processing algorithms. Future plans include an investigation of quantitative analysis of projection radiographic data. Digital data obtained by film scanning can be used with digital image archiving and communications systems. (author)

  13. Intraoral scan bodies in implant dentistry: A systematic review.

    Science.gov (United States)

    Mizumoto, Ryan M; Yilmaz, Burak

    2018-04-05

    Intraoral scan body (ISB) design is highly variable and its role in the digital workflow and accuracy of digital impressions is not well understood. The purpose of this systematic review was to determine the relevant reports pertaining to ISBs with regard to design and accuracy and to describe their evolution and role in the digital dentistry workflow. Special attention was placed on their key features in relation to intraoral scanning technology and the digitization process. A MEDLINE/PubMed search was performed to identify relevant reports pertaining to ISB usage in dentistry. This search included but was not limited to scan body features and design, scan body accuracy, and scan body techniques and the role of ISBs in computer-aided design and computer-aided manufacturing (CAD-CAM) processes. Commercially available scan bodies were examined, and a patient situation was shown highlighting the use of ISBs in the digital workflow. Deficiencies in the reports were found regarding various scan body topics, including ISB features/design, accuracy, and the role of ISBs in CAD-CAM processes. ISBs are complex implant-positioning-transfer devices that play an essential role in the digital workflow and fabrication of accurately fitting implant-supported restorations. With scanner technology rapidly evolving and becoming more widespread, future studies are needed and should be directed toward all parts of the digital workflow when using ISBs. By understanding the basic components of ISBs and how they relate to digital scanning and CAD-CAM technology, more emphasis may be placed on their importance and usage in the digital workflow to ensure accurate transfer of implant position to the virtual and analog definitive cast. Efforts should be made by clinicians to identify an optimal ISB design in relation to the specific intraoral scanning technology being used. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights

  14. A bi-dimensional genome scan for prolificacy traits in pigs shows the existence of multiple epistatic QTL

    Directory of Open Access Journals (Sweden)

    Bidanel Jean P

    2009-12-01

    Full Text Available Abstract Background Prolificacy is the most important trait influencing the reproductive efficiency of pig production systems. The low heritability and sex-limited expression of prolificacy have hindered to some extent the improvement of this trait through artificial selection. Moreover, the relative contributions of additive, dominant and epistatic QTL to the genetic variance of pig prolificacy remain to be defined. In this work, we have undertaken this issue by performing one-dimensional and bi-dimensional genome scans for number of piglets born alive (NBA and total number of piglets born (TNB in a three generation Iberian by Meishan F2 intercross. Results The one-dimensional genome scan for NBA and TNB revealed the existence of two genome-wide highly significant QTL located on SSC13 (P SSC17 (P P P P P Conclusions The complex inheritance of prolificacy traits in pigs has been evidenced by identifying multiple additive (SSC13 and SSC17, dominant and epistatic QTL in an Iberian × Meishan F2 intercross. Our results demonstrate that a significant fraction of the phenotypic variance of swine prolificacy traits can be attributed to first-order gene-by-gene interactions emphasizing that the phenotypic effects of alleles might be strongly modulated by the genetic background where they segregate.

  15. A simple method of digitizing analog scintigrams for quantification and digital archiving

    International Nuclear Information System (INIS)

    Schramm, M.; Kaempfer, B.; Wolf, H.; Clausen, M.; Wendhausen, H.; Henze, E.

    1993-01-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on X-ray film were then digitized seecondarily by three different methods: 300 dpi flatbed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification. (orig.) [de

  16. [A simple method of digitizing analog scintigrams for quantification and digital archiving].

    Science.gov (United States)

    Schramm, M; Kämpfer, B; Wolf, H; Clausen, M; Wendhausen, H; Henze, E

    1993-02-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on x-ray film were then digitized secondarily by three different methods: 300 dpi flat-bed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification.

  17. A genome scan for positive selection in thoroughbred horses.

    Directory of Open Access Journals (Sweden)

    Jingjing Gu

    2009-06-01

    Full Text Available Thoroughbred horses have been selected for exceptional racing performance resulting in system-wide structural and functional adaptations contributing to elite athletic phenotypes. Because selection has been recent and intense in a closed population that stems from a small number of founder animals Thoroughbreds represent a unique population within which to identify genomic contributions to exercise-related traits. Employing a population genetics-based hitchhiking mapping approach we performed a genome scan using 394 autosomal and X chromosome microsatellite loci and identified positively selected loci in the extreme tail-ends of the empirical distributions for (1 deviations from expected heterozygosity (Ewens-Watterson test in Thoroughbred (n = 112 and (2 global differentiation among four geographically diverse horse populations (F(ST. We found positively selected genomic regions in Thoroughbred enriched for phosphoinositide-mediated signalling (3.2-fold enrichment; P<0.01, insulin receptor signalling (5.0-fold enrichment; P<0.01 and lipid transport (2.2-fold enrichment; P<0.05 genes. We found a significant overrepresentation of sarcoglycan complex (11.1-fold enrichment; P<0.05 and focal adhesion pathway (1.9-fold enrichment; P<0.01 genes highlighting the role for muscle strength and integrity in the Thoroughbred athletic phenotype. We report for the first time candidate athletic-performance genes within regions targeted by selection in Thoroughbred horses that are principally responsible for fatty acid oxidation, increased insulin sensitivity and muscle strength: ACSS1 (acyl-CoA synthetase short-chain family member 1, ACTA1 (actin, alpha 1, skeletal muscle, ACTN2 (actinin, alpha 2, ADHFE1 (alcohol dehydrogenase, iron containing, 1, MTFR1 (mitochondrial fission regulator 1, PDK4 (pyruvate dehydrogenase kinase, isozyme 4 and TNC (tenascin C. Understanding the genetic basis for exercise adaptation will be crucial for the identification of genes

  18. Whole genome PCR scanning reveals the syntenic genome structure of toxigenic Vibrio cholerae strains in the O1/O139 population.

    Directory of Open Access Journals (Sweden)

    Bo Pang

    Full Text Available Vibrio cholerae is commonly found in estuarine water systems. Toxigenic O1 and O139 V. cholerae strains have caused cholera epidemics and pandemics, whereas the nontoxigenic strains within these serogroups only occasionally lead to disease. To understand the differences in the genome and clonality between the toxigenic and nontoxigenic strains of V. cholerae serogroups O1 and O139, we employed a whole genome PCR scanning (WGPScanning method, an rrn operon-mediated fragment rearrangement analysis and comparative genomic hybridization (CGH to analyze the genome structure of different strains. WGPScanning in conjunction with CGH revealed that the genomic contents of the toxigenic strains were conservative, except for a few indels located mainly in mobile elements. Minor nucleotide variation in orthologous genes appeared to be the major difference between the toxigenic strains. rrn operon-mediated rearrangements were infrequent in El Tor toxigenic strains tested using I-CeuI digested pulsed-field gel electrophoresis (PFGE analysis and PCR analysis based on flanking sequence of rrn operons. Using these methods, we found that the genomic structures of toxigenic El Tor and O139 strains were syntenic. The nontoxigenic strains exhibited more extensive sequence variations, but toxin coregulated pilus positive (TCP+ strains had a similar structure. TCP+ nontoxigenic strains could be subdivided into multiple lineages according to the TCP type, suggesting the existence of complex intermediates in the evolution of toxigenic strains. The data indicate that toxigenic O1 El Tor and O139 strains were derived from a single lineage of intermediates from complex clones in the environment. The nontoxigenic strains with non-El Tor type TCP may yet evolve into new epidemic clones after attaining toxigenic attributes.

  19. Rapid Prototyping — A Tool for Presenting 3-Dimensional Digital Models Produced by Terrestrial Laser Scanning

    Directory of Open Access Journals (Sweden)

    Juho-Pekka Virtanen

    2014-07-01

    Full Text Available Rapid prototyping has received considerable interest with the introduction of affordable rapid prototyping machines. These machines can be used to manufacture physical models from three-dimensional digital mesh models. In this paper, we compare the results obtained with a new, affordable, rapid prototyping machine, and a traditional professional machine. Two separate data sets are used for this, both of which were acquired using terrestrial laser scanning. Both of the machines were able to produce complex and highly detailed geometries in plastic material from models based on terrestrial laser scanning. The dimensional accuracies and detail levels of the machines were comparable, and the physical artifacts caused by the fused deposition modeling (FDM technique used in the rapid prototyping machines could be found in both models. The accuracy of terrestrial laser scanning exceeded the requirements for manufacturing physical models of large statues and building segments at a 1:40 scale.

  20. Does parental expressed emotion moderate genetic effects in ADHD? An exploration using a genome wide association scan

    NARCIS (Netherlands)

    Sonuga-Barke, E.; Lasky-Su, J.; Neale, B.; Oades, R.D.; Chen, W.; Franke, B.; Buitelaar, J.K.; Banaschewski, T.; Ebstein, R.; Gill, M.; Anney, R.J.; Miranda, A.; Mulas, F.; Roeyers, H.; Rothenberger, A.; Sergeant, J.A.; Steinhausen, H.C.; Thompson, M.; Asherson, P.; Faraone, S.V.

    2008-01-01

    Studies of gene x environment (G x E) interaction in ADHD have previously focused on known risk genes for ADHD and environmentally mediated biological risk. Here we use G x E analysis in the context of a genome-wide association scan to identify novel genes whose effects on ADHD symptoms and comorbid

  1. Does parental expressed emotion moderate genetic effects in ADHD? An exploration using a genome wide association scan.

    NARCIS (Netherlands)

    Sonuga-Barke, E.J.S.; Lasky-Su, J.; Neale, B.; Oades, R.D.; Chen, W.; Franke, B.; Buitelaar, J.K.; Banaschewski, T.; Ebstein, R.P.; Gill, M.; Anney, R.; Miranda, A.; Mulas, F.; Roeyers, H.; Rothenberger, A.; Sergeant, J.A.; Steinhausen, H.C.; Thompson, M.; Asherson, P.; Faraone, S.V.

    2008-01-01

    Studies of gene x environment (G x E) interaction in ADHD have previously focused on known risk genes for ADHD and environmentally mediated biological risk. Here we use G x E analysis in the context of a genome-wide association scan to identify novel genes whose effects on ADHD symptoms and comorbid

  2. Evaluation of digital dental models obtained from dental cone-beam computed tomography scan of alginate impressions

    OpenAIRE

    Jiang, Tingting; Lee, Sang-Mi; Hou, Yanan; Chang, Xin; Hwang, Hyeon-Shik

    2016-01-01

    Objective To investigate the dimensional accuracy of digital dental models obtained from the dental cone-beam computed tomography (CBCT) scan of alginate impressions according to the time elapse when the impressions are stored under ambient conditions. Methods Alginate impressions were obtained from 20 adults using 3 different alginate materials, 2 traditional alginate materials (Alginoplast and Cavex Impressional) and 1 extended-pour alginate material (Cavex ColorChange). The impressions wer...

  3. Evaluating Digital PCR for the Quantification of Human Genomic DNA: Accessible Amplifiable Targets.

    Science.gov (United States)

    Kline, Margaret C; Romsos, Erica L; Duewer, David L

    2016-02-16

    Polymerase chain reaction (PCR) multiplexed assays perform best when the input quantity of template DNA is controlled to within about a factor of √2. To help ensure that PCR assays yield consistent results over time and place, results from methods used to determine DNA quantity need to be metrologically traceable to a common reference. Many DNA quantitation systems can be accurately calibrated with solutions of DNA in aqueous buffer. Since they do not require external calibration, end-point limiting dilution technologies, collectively termed "digital PCR (dPCR)", have been proposed as suitable for value assigning such DNA calibrants. The performance characteristics of several commercially available dPCR systems have recently been documented using plasmid, viral, or fragmented genomic DNA; dPCR performance with more complex materials, such as human genomic DNA, has been less studied. With the goal of providing a human genomic reference material traceably certified for mass concentration, we are investigating the measurement characteristics of several dPCR systems. We here report results of measurements from multiple PCR assays, on four human genomic DNAs treated with four endonuclease restriction enzymes using both chamber and droplet dPCR platforms. We conclude that dPCR does not estimate the absolute number of PCR targets in a given volume but rather the number of accessible and amplifiable targets. While enzymatic restriction of human genomic DNA increases accessibility for some assays, in well-optimized PCR assays it can reduce the number of amplifiable targets and increase assay variability relative to uncut sample.

  4. TU-CD-207-05: A Novel Digital Tomosynthesis System Using Orthogonal Scanning Technique: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Kim, J [Samsung Medical Center, Seoul (Korea, Republic of); Park, C [University of Florida Health Science Center, Gainesville, FL (United States); Kauweloa, K [UTHSCSA, San Antonio, TX (United States); Chung, Y; Han, Y [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Ju, S [Samsung Medical Center, Seoul, Seoul (Korea, Republic of)

    2015-06-15

    Purpose: As an alternative to full tomographic imaging technique such as cone-beam computed tomography (CBCT), there is growing interest to adopt digital tomosynthesis (DTS) for the use of diagnostic as well as therapeutic applications. The aim of this study is to propose a new DTS system using novel orthogonal scanning technique, which can provide superior image quality DTS images compared to the conventional DTS scanning system. Methods: Unlike conventional DTS scanning system, the proposed DTS is reconstructed with two sets of orthogonal patient scans. 1) X-ray projections that are acquired along transverse trajectory and 2) an additional sets of X-ray projections acquired along the vertical direction at the mid angle of the previous transverse scan. To reconstruct DTS, we have used modified filtered backprojection technique to account for the different scanning directions of each projection set. We have evaluated the performance of our method using numerical planning CT data of liver cancer patient and a physical pelvis phantom experiment. The results were compared with conventional DTS techniques with single transverse and vertical scanning. Results: The experiments on both numerical simulation as well as physical experiment showed that the resolution as well as contrast of anatomical structures was much clearer using our method. Specifically, the image quality comparing with transversely scanned DTS showed that the edge and contrast of anatomical structures along Left-Right (LR) directions was comparable however, considerable discrepancy and enhancement could be observed along Superior-Inferior (SI) direction using our method. The opposite was observed when vertically scanned DTS was compared. Conclusion: In this study, we propose a novel DTS system using orthogonal scanning technique. The results indicated that the image quality of our novel DTS system was superior compared to conventional DTS system. This makes our DTS system potentially useful in various

  5. Synchronous-digitization for video rate polarization modulated beam scanning second harmonic generation microscopy

    Science.gov (United States)

    Sullivan, Shane Z.; DeWalt, Emma L.; Schmitt, Paul D.; Muir, Ryan D.; Simpson, Garth J.

    2015-03-01

    Fast beam-scanning non-linear optical microscopy, coupled with fast (8 MHz) polarization modulation and analytical modeling have enabled simultaneous nonlinear optical Stokes ellipsometry (NOSE) and linear Stokes ellipsometry imaging at video rate (15 Hz). NOSE enables recovery of the complex-valued Jones tensor that describes the polarization-dependent observables, in contrast to polarimetry, in which the polarization stated of the exciting beam is recorded. Each data acquisition consists of 30 images (10 for each detector, with three detectors operating in parallel), each of which corresponds to polarization-dependent results. Processing of this image set by linear fitting contracts down each set of 10 images to a set of 5 parameters for each detector in second harmonic generation (SHG) and three parameters for the transmittance of the fundamental laser beam. Using these parameters, it is possible to recover the Jones tensor elements of the sample at video rate. Video rate imaging is enabled by performing synchronous digitization (SD), in which a PCIe digital oscilloscope card is synchronized to the laser (the laser is the master clock.) Fast polarization modulation was achieved by modulating an electro-optic modulator synchronously with the laser and digitizer, with a simple sine-wave at 1/10th the period of the laser, producing a repeating pattern of 10 polarization states. This approach was validated using Z-cut quartz, and NOSE microscopy was performed for micro-crystals of naproxen.

  6. Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications

    International Nuclear Information System (INIS)

    Clauser, Paola; Nagl, Georg; Helbich, Thomas H.; Pinker-Domenig, Katja; Weber, Michael; Kapetas, Panagiotis; Bernathova, Maria; Baltzer, Pascal A.T.

    2016-01-01

    Highlights: • Wide scan-angle DBT alone shows a high detection rate for microcalcifications. • DBT and FFDM can characterize microcalcifications at a comparable level. • Characterization is influenced by reader and by lesion type (benign vs malignant). • DBT might be used as a stand-alone technique for the assessment of microcalcifications. - Abstract: Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients’ history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions’ characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P = 0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25 s, respectively). Conclusion: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen.

  7. Diagnostic performance of digital breast tomosynthesis with a wide scan angle compared to full-field digital mammography for the detection and characterization of microcalcifications

    Energy Technology Data Exchange (ETDEWEB)

    Clauser, Paola, E-mail: paola.clauser@meduniwien.ac.at [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Nagl, Georg [Department for Radiology and Interventional Radiology, Landesklinikum Horn, Spitalgasse 10, 3580 Horn (Austria); Helbich, Thomas H., E-mail: thomas.helbich@meduniwien.ac.at [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Pinker-Domenig, Katja [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Weber, Michael [Department of Biomedical Imaging and Image-Guided Therapy, Division of General and Pediatric Radiology, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria); Kapetas, Panagiotis; Bernathova, Maria; Baltzer, Pascal A.T. [Department of Biomedical Imaging and Image-Guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna, Waehringer Guertel 18-20, 1090 Vienna (Austria)

    2016-12-15

    Highlights: • Wide scan-angle DBT alone shows a high detection rate for microcalcifications. • DBT and FFDM can characterize microcalcifications at a comparable level. • Characterization is influenced by reader and by lesion type (benign vs malignant). • DBT might be used as a stand-alone technique for the assessment of microcalcifications. - Abstract: Objectives: To assess the diagnostic performance of digital breast tomosynthesis (DBT), with a wide scan-angle, compared to full-field digital mammography (FFDM), for the detection and characterization of microcalcifications. Methods: IRB approval was obtained for this retrospective study. We selected 150 FFDM and DBT (50 benign and 50 malignant histologically verified microcalcifications, 50 cases classified as BI-RADS 1). Four radiologists evaluated, in separate sessions and blinded to patients’ history and histology, the presence of microcalcifications. Cases with microcalcifications were assessed for visibility, characteristics, and grade of suspicion using BI-RADS categories. Detection rate and diagnostic performance were calculated. Visibility, lesions’ characteristics and reading time were analysed. Results: Detection rate and visibility were good for both FFDM and DBT, without intra-reader differences (P = 0.510). Inter-reader differences were detected (P < 0.018). Only two lesions were not detected by any reader on either FFDM or DBT. Diagnostic performance with DBT was as good as that of FFDM, but a significant inter-reader difference was found (P = 0.041). High inter-reader variability in the use of the descriptors was found. Reading time for DBT was almost twice that for FFDM (44 and 25 s, respectively). Conclusion: Wide scan-angle DBT enabled the detection and characterization of microcalcifications with no significant differences from FFDM. Inter-reader variability was seen.

  8. SCAN- a maintenance-free flowrate meter with direct digital read-out for computerised control applications in radiochemical plants

    Energy Technology Data Exchange (ETDEWEB)

    Shah, B V; Siddiqui, I A; Theyyunni, T K [Process Engineering and Systems Division, Bhabha Atomic Research Centre, Mumbai (India)

    1994-06-01

    In radiochemical plants, the choice of flowrate sensor is subject to stringent requirements of fail-safe design and freedom from maintenance. The SCAN remote digital direct indicating flowrate meter described in this paper was developed to meet the requirements of flowrate and transmitting it to the control room, and to a computerised control system. SCAN is designed on the principle that flowrate through an orifice is a function of the head of liquid acting upon it. SCAN consists of a small chamber which receives the flow, and discharges it through an orifice located in bottom. The level of liquid in the pot represents the flowrate of the input stream. SCAN has been developed into an accurate, rugged and practical device by refinements in the design of internals, and by introducing a special end-section which makes the calibration insensitive to location. An important feature of SCAN is that it is passive, maintenance free, fail-safe device and contains no moving parts. There is no liquid hold up in the SCAN when idle, which is a desirable feature for the radiochemical plant environment. (author). 3 figs., 2 tabs.

  9. Fast transient digitizer

    International Nuclear Information System (INIS)

    Villa, F.

    1982-01-01

    Method and apparatus for sequentially scanning a plurality of target elements with an electron scanning beam modulated in accordance with variations in a high-frequency analog signal to provide discrete analog signal samples representative of successive portions of the analog signal; coupling the discrete analog signal samples from each of the target elements to a different one of a plurality of high speed storage devices; converting the discrete analog signal samples to equivalent digital signals; and storing the digital signals in a digital memory unit for subsequent measurement or display

  10. Comparison of digital scanning and polyvinyl siloxane impression techniques by dental students: instructional efficiency and attitudes towards technology.

    Science.gov (United States)

    Marti, A M; Harris, B T; Metz, M J; Morton, D; Scarfe, W C; Metz, C J; Lin, W-S

    2017-08-01

    With increasing use of digital scanning with restorative procedures in the dental office, it becomes necessary that educational institutions adopt instructional methodology for introducing this technology together with conventional impression techniques. To compare the time differences between instructing dental students on digital scanning (DS) (LAVA C.O.S. digital impression system) and a conventional impression technique (CI) (polyvinyl siloxane), and to compare students' attitudes and beliefs towards both techniques. Volunteer sophomore dental students (n = 25) with no prior experience in clinical impressions were recruited and IRB consent obtained. Participants responded to a pre-and post-exposure questionnaire. Participants were instructed on the use of both DS and CI for a single tooth full coverage crown restoration using a consecutive sequence of video lecture, investigator-led demonstration and independent impression exercise. The time necessary for each step (minutes) was recorded. Statistical significance was calculated using dependent t-tests (time measurements) and 2-sample Mann-Whitney (questionnaire responses). The time spent teaching students was greater for DS than CI for video lecture (15.95 and 10.07 min, P = 0.0000), demonstration time (9.06 and 4.70 min, P = 0.0000) and impression time (18.17 and 8.59 min, P = 0.0000). Prior to the instruction and practice, students considered themselves more familiar with CI (3.96) than DS (1.96) (P = 0.0000). After the instruction and practice, participants reported CI technique proved significantly easier than expected (pre-instruction: 3.52 and post-instruction: 4.08, P = 0.002). However, overall participants' perception of ease of use for DS was not influenced by this instruction and practice experience (pre-instruction: 3.84 and post-instruction: 3.56, P = 0.106). Despite the results, 96% of participants expressed an expectation that DS will become their predominant impression technique during their

  11. PWMScan: a fast tool for scanning entire genomes with a position-specific weight matrix.

    Science.gov (United States)

    Ambrosini, Giovanna; Groux, Romain; Bucher, Philipp

    2018-03-05

    Transcription factors (TFs) regulate gene expression by binding to specific short DNA sequences of 5 to 20-bp to regulate the rate of transcription of genetic information from DNA to messenger RNA. We present PWMScan, a fast web-based tool to scan server-resident genomes for matches to a user-supplied PWM or TF binding site model from a public database. The web server and source code are available at http://ccg.vital-it.ch/pwmscan and https://sourceforge.net/projects/pwmscan, respectively. giovanna.ambrosini@epfl.ch. SUPPLEMENTARY DATA ARE AVAILABLE AT BIOINFORMATICS ONLINE.

  12. [Constructing 3-dimensional colorized digital dental model assisted by digital photography].

    Science.gov (United States)

    Ye, Hong-qiang; Liu, Yu-shu; Liu, Yun-song; Ning, Jing; Zhao, Yi-jiao; Zhou, Yong-sheng

    2016-02-18

    To explore a method of constructing universal 3-dimensional (3D) colorized digital dental model which can be displayed and edited in common 3D software (such as Geomagic series), in order to improve the visual effect of digital dental model in 3D software. The morphological data of teeth and gingivae were obtained by intra-oral scanning system (3Shape TRIOS), constructing 3D digital dental models. The 3D digital dental models were exported as STL files. Meanwhile, referring to the accredited photography guide of American Academy of Cosmetic Dentistry (AACD), five selected digital photographs of patients'teeth and gingivae were taken by digital single lens reflex camera (DSLR) with the same exposure parameters (except occlusal views) to capture the color data. In Geomagic Studio 2013, after STL file of 3D digital dental model being imported, digital photographs were projected on 3D digital dental model with corresponding position and angle. The junctions of different photos were carefully trimmed to get continuous and natural color transitions. Then the 3D colorized digital dental model was constructed, which was exported as OBJ file or WRP file which was a special file for software of Geomagic series. For the purpose of evaluating the visual effect of the 3D colorized digital model, a rating scale on color simulation effect in views of patients'evaluation was used. Sixteen patients were recruited and their scores on colored and non-colored digital dental models were recorded. The data were analyzed using McNemar-Bowker test in SPSS 20. Universal 3D colorized digital dental model with better color simulation was constructed based on intra-oral scanning and digital photography. For clinical application, the 3D colorized digital dental models, combined with 3D face images, were introduced into 3D smile design of aesthetic rehabilitation, which could improve the patients' cognition for the esthetic digital design and virtual prosthetic effect. Universal 3D colorized

  13. Evaluating genome-wide DNA methylation changes in mice by Methylation Specific Digital Karyotyping

    Directory of Open Access Journals (Sweden)

    Maruoka Shuichiro

    2008-12-01

    Full Text Available Abstract Background The study of genome-wide DNA methylation changes has become more accessible with the development of various array-based technologies though when studying species other than human the choice of applications are limited and not always within reach. In this study, we adapted and tested the applicability of Methylation Specific Digital Karyotyping (MSDK, a non-array based method, for the prospective analysis of epigenetic changes after perinatal nutritional modifications in a mouse model of allergic airway disease. MSDK is a sequenced based method that allows a comprehensive and unbiased methylation profiling. The method generates 21 base pairs long sequence tags derived from specific locations in the genome. The resulting tag frequencies determine in a quantitative manner the methylation level of the corresponding loci. Results Genomic DNA from whole lung was isolated and subjected to MSDK analysis using the methylation-sensitive enzyme Not I as the mapping enzyme and Nla III as the fragmenting enzyme. In a pair wise comparison of the generated mouse MSDK libraries we identified 158 loci that are significantly differentially methylated (P-value = 0.05 after perinatal dietary changes in our mouse model. Quantitative methylation specific PCR and sequence analysis of bisulfate modified genomic DNA confirmed changes in methylation at specific loci. Differences in genomic MSDK tag counts for a selected set of genes, correlated well with changes in transcription levels as measured by real-time PCR. Furthermore serial analysis of gene expression profiling demonstrated a dramatic difference in expressed transcripts in mice exposed to perinatal nutritional changes. Conclusion The genome-wide methylation survey applied in this study allowed for an unbiased methylation profiling revealing subtle changes in DNA methylation in mice maternally exposed to dietary changes in methyl-donor content. The MSDK method is applicable for mouse models

  14. Genome scans on experimentally evolved populations reveal candidate regions for adaptation to plant resistance in the potato cyst nematode Globodera pallida.

    Science.gov (United States)

    Eoche-Bosy, D; Gautier, M; Esquibet, M; Legeai, F; Bretaudeau, A; Bouchez, O; Fournet, S; Grenier, E; Montarry, J

    2017-09-01

    Improving resistance durability involves to be able to predict the adaptation speed of pathogen populations. Identifying the genetic bases of pathogen adaptation to plant resistances is a useful step to better understand and anticipate this phenomenon. Globodera pallida is a major pest of potato crop for which a resistance QTL, GpaV vrn , has been identified in Solanum vernei. However, its durability is threatened as G. pallida populations are able to adapt to the resistance in few generations. The aim of this study was to investigate the genomic regions involved in the resistance breakdown by coupling experimental evolution and high-density genome scan. We performed a whole-genome resequencing of pools of individuals (Pool-Seq) belonging to G. pallida lineages derived from two independent populations having experimentally evolved on susceptible and resistant potato cultivars. About 1.6 million SNPs were used to perform the genome scan using a recent model testing for adaptive differentiation and association to population-specific covariables. We identified 275 outliers and 31 of them, which also showed a significant reduction in diversity in adapted lineages, were investigated for their genic environment. Some candidate genomic regions contained genes putatively encoding effectors and were enriched in SPRYSECs, known in cyst nematodes to be involved in pathogenicity and in (a)virulence. Validated candidate SNPs will provide a useful molecular tool to follow frequencies of virulence alleles in natural G. pallida populations and define efficient strategies of use of potato resistances maximizing their durability. © 2017 John Wiley & Sons Ltd.

  15. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  16. Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions

    Science.gov (United States)

    Yang, Xin; Lv, Pin; Liu, Yihong; Si, Wenjie; Feng, Hailan

    2015-01-01

    In this study, the accuracy (precision and trueness) of digital impressions and the fitness of single crowns manufactured based on digital impressions were evaluated. #14-17 epoxy resin dentitions were made, while full-crown preparations of extracted natural teeth were embedded at #16. (1) To assess precision, deviations among repeated scan models made by intraoral scanner TRIOS and MHT and model scanner D700 and inEos were calculated through best-fit algorithm and three-dimensional (3D) comparison. Root mean square (RMS) and color-coded difference images were offered. (2) To assess trueness, micro computed tomography (micro-CT) was used to get the reference model (REF). Deviations between REF and repeated scan models (from (1)) were calculated. (3) To assess fitness, single crowns were manufactured based on TRIOS, MHT, D700 and inEos scan models. The adhesive gaps were evaluated under stereomicroscope after cross-sectioned. Digital impressions showed lower precision and better trueness. Except for MHT, the means of RMS for precision were lower than 10 μm. Digital impressions showed better internal fitness. Fitness of single crowns based on digital impressions was up to clinical standard. Digital impressions could be an alternative method for single crowns manufacturing. PMID:28793417

  17. Accuracy of Digital Impressions and Fitness of Single Crowns Based on Digital Impressions

    Directory of Open Access Journals (Sweden)

    Xin Yang

    2015-06-01

    Full Text Available In this study, the accuracy (precision and trueness of digital impressions and the fitness of single crowns manufactured based on digital impressions were evaluated. #14-17 epoxy resin dentitions were made, while full-crown preparations of extracted natural teeth were embedded at #16. (1 To assess precision, deviations among repeated scan models made by intraoral scanner TRIOS and MHT and model scanner D700 and inEos were calculated through best-fit algorithm and three-dimensional (3D comparison. Root mean square (RMS and color-coded difference images were offered. (2 To assess trueness, micro computed tomography (micro-CT was used to get the reference model (REF. Deviations between REF and repeated scan models (from (1 were calculated. (3 To assess fitness, single crowns were manufactured based on TRIOS, MHT, D700 and inEos scan models. The adhesive gaps were evaluated under stereomicroscope after cross-sectioned. Digital impressions showed lower precision and better trueness. Except for MHT, the means of RMS for precision were lower than 10 μm. Digital impressions showed better internal fitness. Fitness of single crowns based on digital impressions was up to clinical standard. Digital impressions could be an alternative method for single crowns manufacturing.

  18. Accuracy and efficiency of full-arch digitalization and 3D printing: A comparison between desktop model scanners, an intraoral scanner, a CBCT model scan, and stereolithographic 3D printing.

    Science.gov (United States)

    Wesemann, Christian; Muallah, Jonas; Mah, James; Bumann, Axel

    2017-01-01

    The primary objective of this study was to compare the accuracy and time efficiency of an indirect and direct digitalization workflow with that of a three-dimensional (3D) printer in order to identify the most suitable method for orthodontic use. A master model was measured with a coordinate measuring instrument. The distances measured were the intercanine width, the intermolar width, and the dental arch length. Sixty-four scans were taken with each of the desktop scanners R900 and R700 (3Shape), the intraoral scanner TRIOS Color Pod (3Shape), and the Promax 3D Mid cone beam computed tomography (CBCT) unit (Planmeca). All scans were measured with measuring software. One scan was selected and printed 37 times on the D35 stereolithographic 3D printer (Innovation MediTech). The printed models were measured again using the coordinate measuring instrument. The most accurate results were obtained by the R900. The R700 and the TRIOS intraoral scanner showed comparable results. CBCT-3D-rendering with the Promax 3D Mid CBCT unit revealed significantly higher accuracy with regard to dental casts than dental impressions. 3D printing offered a significantly higher level of deviation than digitalization with desktop scanners or an intraoral scanner. The chairside time required for digital impressions was 27% longer than for conventional impressions. Conventional impressions, model casting, and optional digitization with desktop scanners remains the recommended workflow process. For orthodontic demands, intraoral scanners are a useful alternative for full-arch scans. For prosthodontic use, the scanning scope should be less than one quadrant and three additional teeth.

  19. Image quality characteristics of a novel colour scanning digital ophthalmoscope (SDO) compared with fundus photography.

    Science.gov (United States)

    Strauss, Rupert W; Krieglstein, Tina R; Priglinger, Siegfried G; Reis, Werner; Ulbig, Michael W; Kampik, Anselm; Neubauer, Aljoscha S

    2007-11-01

    To establish a set of quality parameters for grading image quality and apply those to evaluate the fundus image quality obtained by a new scanning digital ophthalmoscope (SDO) compared with standard slide photography. On visual analogue scales a total of eight image characteristics were defined: overall quality, contrast, colour brilliance, focus (sharpness), resolution and details, noise, artefacts and validity of clinical assessment. Grading was repeated after 4 months to assess repeatability. Fundus images of 23 patients imaged digitally by SDO and by Zeiss 450FF fundus camera using Kodak film were graded side-by-side by three graders. Lens opacity was quantified with the Interzeag Lens Opacity Meter 701. For all of the eight scales of image quality, good repeatability within the graders (mean Kendall's W 0.69) was obtained after 4 months. Inter-grader agreement ranged between 0.31 and 0.66. Despite the SDO's limited nominal image resolution of 720 x 576 pixels, the Zeiss FF 450 camera performed better in only two of the subscales - noise (p = 0.001) and artefacts (p = 0.01). Lens opacities significantly influenced only the two subscales 'resolution' and 'details', which deteriorated with increasing media opacities for both imaging systems. Distinct scales to grade image characteristics of different origin were developed and validated. Overall SDO digital imaging was found to provide fundus pictures of a similarly high level of quality as expert photography on slides.

  20. Intraoral scanning systems - a current overview.

    Science.gov (United States)

    Zimmermann, M; Mehl, A; Mörmann, W H; Reich, S

    2015-01-01

    There is no doubt today about the possibilities and potential of digital impression-taking with the aid of intraoral optical impression systems, and the past few years have seen a considerable increase in the range of optical intraoral scanners available on the market. On the strength of numerous innovations and a wider range of indications in orthodontics and implantology, intraoral scanning systems appear to be a highly promising development for the future. Digital impression-taking with intraoral scanners has already shown itself in some respects to be clearly superior to conventional impression- taking. Particularly worthy of mention is the versatile integration of digital impressions into diagnostic and treatment concepts to provide a customizable healthcare solution for the patient. It remains exciting to look forward to future developments that will allow us to observe digital impression-taking--as with other digital applications already established in everyday life--becoming firmly established in the routine of dentistry and dental technology. This article presents an overview of the benefits and limitations of digital impression-taking using intraoral scanning systems, and includes a summary of all the relevant intraoral scanners available on the market at present.

  1. Detector, collimator and real-time reconstructor for a new scanning-beam digital x-ray (SBDX) prototype.

    Science.gov (United States)

    Speidel, Michael A; Tomkowiak, Michael T; Raval, Amish N; Dunkerley, David A P; Slagowski, Jordan M; Kahn, Paul; Ku, Jamie; Funk, Tobias

    Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system for low dose cardiac imaging. The use of a narrow scanned x-ray beam in SBDX reduces detected x-ray scatter and improves dose efficiency, however the tight beam collimation also limits the maximum achievable x-ray fluence. To increase the fluence available for imaging, we have constructed a new SBDX prototype with a wider x-ray beam, larger-area detector, and new real-time image reconstructor. Imaging is performed with a scanning source that generates 40,328 narrow overlapping projections from 71 × 71 focal spot positions for every 1/15 s scan period. A high speed 2-mm thick CdTe photon counting detector was constructed with 320×160 elements and 10.6 cm × 5.3 cm area (full readout every 1.28 μs), providing an 86% increase in area over the previous SBDX prototype. A matching multihole collimator was fabricated from layers of tungsten, brass, and lead, and a multi-GPU reconstructor was assembled to reconstruct the stream of captured detector images into full field-of-view images in real time. Thirty-two tomosynthetic planes spaced by 5 mm plus a multiplane composite image are produced for each scan frame. Noise equivalent quanta on the new SBDX prototype measured 63%-71% higher than the previous prototype. X-ray scatter fraction was 3.9-7.8% when imaging 23.3-32.6 cm acrylic phantoms, versus 2.3-4.2% with the previous prototype. Coronary angiographic imaging at 15 frame/s was successfully performed on the new SBDX prototype, with live display of either a multiplane composite or single plane image.

  2. Does parental expressed emotion moderate genetic effects in ADHD? An exploration using a genome wide association scan

    OpenAIRE

    Sonuga-Barke, E.; Lasky-Su, J.; Neale, B.; Oades, R.D.; Chen, W.; Franke, B.; Buitelaar, J.K.; Banaschewski, T.; Ebstein, R.; Gill, M.; Anney, R.J.; Miranda, A.; Mulas, F.; Roeyers, H.; Rothenberger, A.

    2008-01-01

    Studies of gene x environment (G x E) interaction in ADHD have previously focused on known risk genes for ADHD and environmentally mediated biological risk. Here we use G x E analysis in the context of a genome-wide association scan to identify novel genes whose effects on ADHD symptoms and comorbid conduct disorder are moderated by high maternal expressed emotion (EE). SNPs (600,000) were genotyped in 958 ADHD proband-parent trios. After applying data cleaning procedures we examined 429,981 ...

  3. Genome-wide scan for visceral leishmaniasis in mixed-breed dogs identifies candidate genes involved in T helper cells and macrophage signaling

    Science.gov (United States)

    We conducted a genome-wide scan for visceral leishmaniasis in mixed-breed dogs from a highly endemic area in Brazil using 149,648 single nucleotide polymorphism (SNP) markers genotyped in 20 cases and 28 controls. Using a mixed model approach, we found two candidate loci on canine autosomes 1 and 2....

  4. Digital Droplet Multiple Displacement Amplification (ddMDA for Whole Genome Sequencing of Limited DNA Samples.

    Directory of Open Access Journals (Sweden)

    Minsoung Rhee

    Full Text Available Multiple displacement amplification (MDA is a widely used technique for amplification of DNA from samples containing limited amounts of DNA (e.g., uncultivable microbes or clinical samples before whole genome sequencing. Despite its advantages of high yield and fidelity, it suffers from high amplification bias and non-specific amplification when amplifying sub-nanogram of template DNA. Here, we present a microfluidic digital droplet MDA (ddMDA technique where partitioning of the template DNA into thousands of sub-nanoliter droplets, each containing a small number of DNA fragments, greatly reduces the competition among DNA fragments for primers and polymerase thereby greatly reducing amplification bias. Consequently, the ddMDA approach enabled a more uniform coverage of amplification over the entire length of the genome, with significantly lower bias and non-specific amplification than conventional MDA. For a sample containing 0.1 pg/μL of E. coli DNA (equivalent of ~3/1000 of an E. coli genome per droplet, ddMDA achieves a 65-fold increase in coverage in de novo assembly, and more than 20-fold increase in specificity (percentage of reads mapping to E. coli compared to the conventional tube MDA. ddMDA offers a powerful method useful for many applications including medical diagnostics, forensics, and environmental microbiology.

  5. Special raster scanning for reduction of charging effects in scanning electron microscopy.

    Science.gov (United States)

    Suzuki, Kazuhiko; Oho, Eisaku

    2014-01-01

    A special raster scanning (SRS) method for reduction of charging effects is developed for the field of SEM. Both a conventional fast scan (horizontal direction) and an unusual scan (vertical direction) are adopted for acquiring raw data consisting of many sub-images. These data are converted to a proper SEM image using digital image processing techniques. About sharpness of the image and reduction of charging effects, the SRS is compared with the conventional fast scan (with frame-averaging) and the conventional slow scan. Experimental results show the effectiveness of SRS images. By a successful combination of the proposed scanning method and low accelerating voltage (LV)-SEMs, it is expected that higher-quality SEM images can be more easily acquired by the considerable reduction of charging effects, while maintaining the resolution. © 2013 Wiley Periodicals, Inc.

  6. Digital Technology in the protection of cultural heritage Bao Fan Temple mural digital mapping survey

    Directory of Open Access Journals (Sweden)

    Y. Zheng

    2015-08-01

    Full Text Available Peng Xi county, Sichuan province, the Bao Fan temple mural digitization survey mapping project: we use three-dimensional laserscanning, multi-baseline definition digital photography, multi-spectral digital image acquisition and other technologies for digital survey mapping. The purpose of this project is to use modern mathematical reconnaissance mapping means to obtain accurate mural shape, color, quality and other data. Combined with field investigation and laboratory analysis results, and based on a comprehensive survey and study, a comprehensive analysis of the historical Bao Fan Temple mural artistic and scientific value was conducted. A study of the mural’s many qualities (structural, material, technique, preservation environment, degradation, etc. reveal all aspects of the information carried by the Bao Fan Temple mural. From multiple angles (archeology, architecture, surveying, conservation science and other disciplines an assessment for the Bao Fan Temple mural provides basic data and recommendations for conservation of the mural. In order to achieve the conservation of cultural relics in the Bao Fan Temple mural digitization survey mapping process, we try to apply the advantages of three-dimensional laser scanning equipment. For wall murals this means obtaining three-dimensional scale data from the scan of the building and through the analysis of these data to help determine the overall condition of the settlement as well as the deformation of the wall structure. Survey analysis provides an effective set of conclusions and suggestions for appropriate mural conservation. But before data collection, analysis and research need to first to select the appropriate scanning equipment, set the appropriate scanning accuracy and layout position of stations necessary to determine the scope of required data. We use the fine features of the three-dimensional laser scanning measuring arm to scan the mural surface deformation degradation to reflect

  7. Digital Technology in the protection of cultural heritage Bao Fan Temple mural digital mapping survey

    Science.gov (United States)

    Zheng, Y.

    2015-08-01

    Peng Xi county, Sichuan province, the Bao Fan temple mural digitization survey mapping project: we use three-dimensional laserscanning, multi-baseline definition digital photography, multi-spectral digital image acquisition and other technologies for digital survey mapping. The purpose of this project is to use modern mathematical reconnaissance mapping means to obtain accurate mural shape, color, quality and other data. Combined with field investigation and laboratory analysis results, and based on a comprehensive survey and study, a comprehensive analysis of the historical Bao Fan Temple mural artistic and scientific value was conducted. A study of the mural's many qualities (structural, material, technique, preservation environment, degradation, etc.) reveal all aspects of the information carried by the Bao Fan Temple mural. From multiple angles (archeology, architecture, surveying, conservation science and other disciplines) an assessment for the Bao Fan Temple mural provides basic data and recommendations for conservation of the mural. In order to achieve the conservation of cultural relics in the Bao Fan Temple mural digitization survey mapping process, we try to apply the advantages of three-dimensional laser scanning equipment. For wall murals this means obtaining three-dimensional scale data from the scan of the building and through the analysis of these data to help determine the overall condition of the settlement as well as the deformation of the wall structure. Survey analysis provides an effective set of conclusions and suggestions for appropriate mural conservation. But before data collection, analysis and research need to first to select the appropriate scanning equipment, set the appropriate scanning accuracy and layout position of stations necessary to determine the scope of required data. We use the fine features of the three-dimensional laser scanning measuring arm to scan the mural surface deformation degradation to reflect the actual state of

  8. Development and validation of novel digitalized cervicography system

    Science.gov (United States)

    Kim, Soo-Nyung; Kim, Yun Hwan; Nam, Kye-Hyun; Lee, Seon-Kyung; Lee, Tae Sung; Choi, Ho-Sun; Han, Sei-Jun

    2016-01-01

    Objective Digital cervicography systems would be expected to reduce the costs of film cervicography, and provide the opportunity for "telemedicine-based" screening. We aimed to develop web-based digital cervicography system, and validate it compared with conventional film cervicography. Methods A hundred cases from five centers were prospectively included, and cervical images (analogue, digitalized by scanning analogue, and digital) were taken separately using both analogue (Cerviscope) and digital camera (Dr. Cervicam) in each patient. Nine specialists evaluated the three kinds of images of each case with time interval between evaluations of each image. To validate novel digitalized system, we analyzed intra-observer variance among evaluation results of three kinds of images. Results Sixty-three cases were finally analyzed after excluding technically defective cases that cannot be evaluable on analogue images. The generalized kappa for analogue versus digital image was 0.83, for analogue versus scanned image 0.72, and for digital versus scanned image was 0.71; all were in excellent consensus. Conclusion Digitalized cervicography system can be substituted for the film cervicography very reliably, and can be used as a promising telemedicine tool for cervical cancer screening. PMID:27200314

  9. Future approaches to digital systems

    International Nuclear Information System (INIS)

    Woodrough, R.E.; Beckmann, E.; Jenkins, D.; Belcher, D.

    1984-01-01

    The introduction of the first digital imaging systems has led to the concept of a totally digital imaging department - the 'filmless department'. This concept and its associated network system for digital departments are briefly considered. A transducer system of scanned projection radiography with solid state detectors used in digital chest imaging is described. The principles of this transducer system are applicable to other forms of digital radiography. (U.K.)

  10. A genome-wide scan in families with maturity-onset diabetes of the young

    DEFF Research Database (Denmark)

    Frayling, Timothy M; Lindgren, Cecilia M; Chevre, Jean Claude

    2003-01-01

    Maturity-onset diabetes of the young (MODY) is a heterogeneous single gene disorder characterized by non-insulin-dependent diabetes, an early onset and autosomal dominant inheritance. Mutations in six genes have been shown to cause MODY. Approximately 15-20% of families fitting MODY criteria do...... not have mutations in any of the known genes. These families provide a rich resource for the identification of new MODY genes. This will potentially enable further dissection of clinical heterogeneity and bring new insights into mechanisms of beta-cell dysfunction. To facilitate the identification of novel...... MODY loci, we combined the results from three genome-wide scans on a total of 23 families fitting MODY criteria. We used both a strict parametric model of inheritance with heterogeneity and a model-free analysis. We did not identify any single novel locus but provided putative evidence for linkage...

  11. Genome scan for linkage to Gilles de la Tourette syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Barr, C.L.; Livingston, J.; Williamson, R. [and others

    1994-09-01

    Gilles de la Tourette Syndrome (TS) is a familial, neuropsychiatric disorder characterized by chronic, intermittent motor and vocal tics. In addition to tics, affected individuals frequently display symptoms such as attention-deficit hyperactivity disorder and/or obsessive compulsive disorder. Genetic analyses of family data have suggested that susceptibility to the disorder is most likely due to a single genetic locus with a dominant mode of transmission and reduced penetrance. In the search for genetic linkage for TS, we have collected well-characterized pedigrees with multiple affected individuals on whom extensive diagnostic evaluations have been done. The first stage of our study is to scan the genome systematically using a panel of uniformly spaced (10 to 20 cM), highly polymorphic, microsatellite markers on 5 families segregating TS. To date, 290 markers have been typed and 3,660 non-overlapping cM of the genome have been excluded for possible linkage under the assumption of genetic homogeneity. Because of the possibility of locus heterogeneity overall summed exclusion is not considered tantamount to absolute exclusion of a disease locus in that region. The results from each family are carefully evaluated and a positive lod score in a single family is followed up by typing closely linked markers. Linkage to TS was examined by two-point analysis using the following genetic model: single autosomal dominant gene with gene frequency .003 and maximum penetrance of .99. An age-of-onset correction is included using a linear function increasing from age 2 years to 21 years. A small rate of phenocopies is also incorporated into the model. Only individuals with TS or CMT according to DSM III-R criteria were regarded as affected for the purposes of this summary. Additional markers are being tested to provide coverage at 5 cM intervals. Moreover, we are currently analyzing the data non-parametrically using the Affected-Pedigree-Member Method of linkage analysis.

  12. Viral RNA polymerase scanning and the gymnastics of Sendai virus RNA synthesis

    International Nuclear Information System (INIS)

    Kolakofsky, Daniel; Le Mercier, Philippe; Iseni, Frederic; Garcin, Dominique

    2004-01-01

    mRNA synthesis from nonsegmented negative-strand RNA virus (NNV) genomes is unique in that the genome RNA is embedded in an N protein assembly (the nucleocapsid) and the viral RNA polymerase does not dissociate from the template after release of each mRNA, but rather scans the genome RNA for the next gene-start site. A revised model for NNV RNA synthesis is presented, in which RNA polymerase scanning plays a prominent role. Polymerase scanning of the template is known to occur as the viral transcriptase negotiates gene junctions without falling off the template

  13. A novel method, digital genome scanning detects KRAS gene amplification in gastric cancers: involvement of overexpressed wild-type KRAS in downstream signaling and cancer cell growth

    Directory of Open Access Journals (Sweden)

    Yanagihara Kazuyoshi

    2009-06-01

    Full Text Available Abstract Background Gastric cancer is the third most common malignancy affecting the general population worldwide. Aberrant activation of KRAS is a key factor in the development of many types of tumor, however, oncogenic mutations of KRAS are infrequent in gastric cancer. We have developed a novel quantitative method of analysis of DNA copy number, termed digital genome scanning (DGS, which is based on the enumeration of short restriction fragments, and does not involve PCR or hybridization. In the current study, we used DGS to survey copy-number alterations in gastric cancer cells. Methods DGS of gastric cancer cell lines was performed using the sequences of 5000 to 15000 restriction fragments. We screened 20 gastric cancer cell lines and 86 primary gastric tumors for KRAS amplification by quantitative PCR, and investigated KRAS amplification at the DNA, mRNA and protein levels by mutational analysis, real-time PCR, immunoblot analysis, GTP-RAS pull-down assay and immunohistochemical analysis. The effect of KRAS knock-down on the activation of p44/42 MAP kinase and AKT and on cell growth were examined by immunoblot and colorimetric assay, respectively. Results DGS analysis of the HSC45 gastric cancer cell line revealed the amplification of a 500-kb region on chromosome 12p12.1, which contains the KRAS gene locus. Amplification of the KRAS locus was detected in 15% (3/20 of gastric cancer cell lines (8–18-fold amplification and 4.7% (4/86 of primary gastric tumors (8–50-fold amplification. KRAS mutations were identified in two of the three cell lines in which KRAS was amplified, but were not detected in any of the primary tumors. Overexpression of KRAS protein correlated directly with increased KRAS copy number. The level of GTP-bound KRAS was elevated following serum stimulation in cells with amplified wild-type KRAS, but not in cells with amplified mutant KRAS. Knock-down of KRAS in gastric cancer cells that carried amplified wild

  14. A novel method, digital genome scanning detects KRAS gene amplification in gastric cancers: involvement of overexpressed wild-type KRAS in downstream signaling and cancer cell growth

    International Nuclear Information System (INIS)

    Mita, Hiroaki; Yanagihara, Kazuyoshi; Fujita, Masahiro; Hosokawa, Masao; Kusano, Masanobu; Sabau, Sorin Vasile; Tatsumi, Haruyuki; Imai, Kohzoh; Shinomura, Yasuhisa; Tokino, Takashi; Toyota, Minoru; Aoki, Fumio; Akashi, Hirofumi; Maruyama, Reo; Sasaki, Yasushi; Suzuki, Hiromu; Idogawa, Masashi; Kashima, Lisa

    2009-01-01

    Gastric cancer is the third most common malignancy affecting the general population worldwide. Aberrant activation of KRAS is a key factor in the development of many types of tumor, however, oncogenic mutations of KRAS are infrequent in gastric cancer. We have developed a novel quantitative method of analysis of DNA copy number, termed digital genome scanning (DGS), which is based on the enumeration of short restriction fragments, and does not involve PCR or hybridization. In the current study, we used DGS to survey copy-number alterations in gastric cancer cells. DGS of gastric cancer cell lines was performed using the sequences of 5000 to 15000 restriction fragments. We screened 20 gastric cancer cell lines and 86 primary gastric tumors for KRAS amplification by quantitative PCR, and investigated KRAS amplification at the DNA, mRNA and protein levels by mutational analysis, real-time PCR, immunoblot analysis, GTP-RAS pull-down assay and immunohistochemical analysis. The effect of KRAS knock-down on the activation of p44/42 MAP kinase and AKT and on cell growth were examined by immunoblot and colorimetric assay, respectively. DGS analysis of the HSC45 gastric cancer cell line revealed the amplification of a 500-kb region on chromosome 12p12.1, which contains the KRAS gene locus. Amplification of the KRAS locus was detected in 15% (3/20) of gastric cancer cell lines (8–18-fold amplification) and 4.7% (4/86) of primary gastric tumors (8–50-fold amplification). KRAS mutations were identified in two of the three cell lines in which KRAS was amplified, but were not detected in any of the primary tumors. Overexpression of KRAS protein correlated directly with increased KRAS copy number. The level of GTP-bound KRAS was elevated following serum stimulation in cells with amplified wild-type KRAS, but not in cells with amplified mutant KRAS. Knock-down of KRAS in gastric cancer cells that carried amplified wild-type KRAS resulted in the inhibition of cell growth and

  15. Atomized scan strategy for high definition for VR application

    Science.gov (United States)

    Huang, Shuping; Ran, Feng; Ji, Yuan; Chen, Wendong

    2017-10-01

    Silicon-based OLED (Organic Light Emitting Display) microdisplay technology begins to attract people's attention in the emerging VR and AR devices. The high display frame refresh rate is an important solution to alleviate the dizziness in VR applications. Traditional display circuit drivers use the analog method or the digital PWM method that follow the serial scan order from the first pixel to the last pixel by using the shift registers. This paper proposes a novel atomized scan strategy based on the digital fractal scan strategy using the pseudo-random scan order. It can be used to realize the high frame refresh rate with the moderate pixel clock frequency in the high definition OLED microdisplay. The linearity of the gray level is also improved compared with the Z fractal scan strategy.

  16. Digital Conically Scanned L-Band Radar, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed effort seeks to develop a digitally steered polarimetric phased array L-Band radar utilizing a novel, high performance architecture leveraging recent...

  17. A simple method of digitizing analog scintigrams for quantification and digital archiving. Eine einfache Methode der Digitalisierung von Analogszintigrammen zur Quantifizierung und digitalen Archivierung

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, M. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Kaempfer, B. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Wolf, H. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Clausen, M. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Wendhausen, H. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Henze, E. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany))

    1993-02-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on X-ray film were then digitized seecondarily by three different methods: 300 dpi flatbed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification. (orig.)

  18. (Reexamining the attitudes of comic book store patrons in the digital era

    Directory of Open Access Journals (Sweden)

    J. Richard Stevens

    2015-09-01

    Full Text Available As digital comic book consumption continues to rise in popularity, the comic book community appears conflicted over the effects that digital scans have on the meaning of collecting and reading comic books. Historically, comic ownership served as the locus of comic fan social capital; will digital scans hold the same cultural capital as printed books? And does postpurchased digital scan dissemination primarily hurt copyright holders through lost sales, or does it help through social promotion? Building on an analysis of fan attitudes toward digital comic book texts, we seek to account for the limitations of locality by surveying the attitudes of comic book store patrons concerning their attitudes toward physical and digital comic book texts.

  19. Scanning-beam digital x-ray (SBDX) technology for interventional and diagnostic cardiac angiography

    International Nuclear Information System (INIS)

    Speidel, Michael A.; Wilfley, Brian P.; Star-Lack, Josh M.; Heanue, Joseph A.; Van Lysel, Michael S.

    2006-01-01

    The scanning-beam digital x-ray (SBDX) system is designed for x-ray dose reduction in cardiac angiographic applications. Scatter reduction, efficient detection of primary x-rays, and an inverse beam geometry are the main components of the entrance dose reduction strategy. This paper reports the construction of an SBDX prototype, image reconstruction techniques, and measurements of spatial resolution and x-ray output. The x-ray source has a focal spot that is electronically scanned across a large-area transmission target. A multihole collimator beyond the target defines a series of x-ray beams directed at a distant small-area detector array. The prototype has a 23 cmx23 cm target, 100x100 focal spot positions, and a 5 cmx5 cm CdTe detector positioned 150 cm from the target. With this nonmechanical method of beam scanning, patient images with low detected scatter are generated at up to 30 frame/s. SBDX data acquisition is tomosynthetic. The prototype simultaneously reconstructs 16 planes spaced throughout the cardiac volume using shift-and-add backprojection. Image frames analogous to conventional projection images are generated with a multiplane compositing algorithm. Single-plane versus multiplane reconstruction of contrast-filled coronary arteries is demonstrated with images of the porcine heart. Phantom and porcine imaging studies show multiplane reconstruction is practicable under clinically realistic levels of patient attenuation and cardiac motion. The modulation transfer function for an in-plane slit at mechanical isocenter measured 0.41-0.56 at 1 cycle/mm, depending on the detector element to image pixel interpolation technique. Modeling indicates that desired gains in spatial resolution are achievable by halving the detector element width. The x-ray exposure rate 15 cm below isocenter, without table or patient in the beam, measured 11.5 R/min at 120 kVp, 24.3 kWp and 3.42 R/min at 70 kVp, 14.2 kWp

  20. Digital elevation model production from scanned topographic contour maps via thin plate spline interpolation

    International Nuclear Information System (INIS)

    Soycan, Arzu; Soycan, Metin

    2009-01-01

    GIS (Geographical Information System) is one of the most striking innovation for mapping applications supplied by the developing computer and software technology to users. GIS is a very effective tool which can show visually combination of the geographical and non-geographical data by recording these to allow interpretations and analysis. DEM (Digital Elevation Model) is an inalienable component of the GIS. The existing TM (Topographic Map) can be used as the main data source for generating DEM by amanual digitizing or vectorization process for the contours polylines. The aim of this study is to examine the DEM accuracies, which were obtained by TMs, as depending on the number of sampling points and grid size. For these purposes, the contours of the several 1/1000 scaled scanned topographical maps were vectorized. The different DEMs of relevant area have been created by using several datasets with different numbers of sampling points. We focused on the DEM creation from contour lines using gridding with RBF (Radial Basis Function) interpolation techniques, namely TPS as the surface fitting model. The solution algorithm and a short review of the mathematical model of TPS (Thin Plate Spline) interpolation techniques are given. In the test study, results of the application and the obtained accuracies are drawn and discussed. The initial object of this research is to discuss the requirement of DEM in GIS, urban planning, surveying engineering and the other applications with high accuracy (a few deci meters). (author)

  1. 3D mass digitization: a milestone for archeological documentation

    Directory of Open Access Journals (Sweden)

    Pedro Santos

    2017-05-01

    Full Text Available In the heritage field, the demand for fast and efficient 3D digitization technologies for historic remains is increasing. Besides, 3D digitization has proved to be a promising approach to enable precise reconstructions of objects. Yet, unlike the digital acquisition of cultural goods in 2D widely used today, 3D digitization often still requires a significant investment of time and money. To make it more widely available to heritage institutions, the Competence Center for Cultural Heritage Digitization at the Fraunhofer Institute for Computer Graphics Research IGD has developed CultLab3D, the world’s first 3D mass digitization facility for collections of three-dimensional objects. CultLab3D is specifically designed to automate the entire 3D digitization process thus allowing to scan and archive objects on a large-scale. Moreover, scanning and lighting technologies are combined to capture the exact geometry, texture, and optical material properties of artefacts to produce highly accurate photo-realistic representations. The unique setup allows to shorten the time needed for digitization to several minutes per artefact instead of hours, as required by conventional 3D scanning methods.

  2. The Application of Restriction Landmark Genome Scanning Method for Surveillance of Non-Mendelian Inheritance in F1 Hybrids

    Directory of Open Access Journals (Sweden)

    Tomoko Takamiya

    2009-01-01

    Full Text Available We analyzed inheritance of DNA methylation in reciprocal F1 hybrids (subsp. japonica cv. Nipponbare × subsp. indica cv. Kasalath of rice (Oryza sativa L. using restriction landmark genome scanning (RLGS, and detected differing RLGS spots between the parents and reciprocal F1 hybrids. MspI/HpaII restriction sites in the DNA from these different spots were suspected to be heterozygously methylated in the Nipponbare parent. These spots segregated in F1 plants, but did not segregate in selfed progeny of Nipponbare, showing non-Mendelian inheritance of the methylation status. As a result of RT-PCR and sequencing, a specific allele of the gene nearest to the methylated sites was expressed in reciprocal F1 plants, showing evidence of biased allelic expression. These results show the applicability of RLGS for scanning of non-Mendelian inheritance of DNA methylation and biased allelic expression.

  3. Population genomic scans suggest novel genes underlie convergent flowering time evolution in the introduced range of Arabidopsis thaliana.

    Science.gov (United States)

    Gould, Billie A; Stinchcombe, John R

    2017-01-01

    A long-standing question in evolutionary biology is whether the evolution of convergent phenotypes results from selection on the same heritable genetic components. Using whole-genome sequencing and genome scans, we tested whether the evolution of parallel longitudinal flowering time clines in the native and introduced ranges of Arabidopsis thaliana has a similar genetic basis. We found that common variants of large effect on flowering time in the native range do not appear to have been under recent strong selection in the introduced range. We identified a set of 38 new candidate genes that are putatively linked to the evolution of flowering time. A high degree of conditional neutrality of flowering time variants between the native and introduced range may preclude parallel evolution at the level of genes. Overall, neither gene pleiotropy nor available standing genetic variation appears to have restricted the evolution of flowering time to high-frequency variants from the native range or to known flowering time pathway genes. © 2016 John Wiley & Sons Ltd.

  4. Soft control of scanning probe microscope with high flexibility.

    Science.gov (United States)

    Liu, Zhenghui; Guo, Yuzheng; Zhang, Zhaohui; Zhu, Xing

    2007-01-01

    Most commercial scanning probe microscopes have multiple embedded digital microprocessors and utilize complex software for system control, which is not easily obtained or modified by researchers wishing to perform novel and special applications. In this paper, we present a simple and flexible control solution that just depends on software running on a single-processor personal computer with real-time Linux operating system to carry out all the control tasks including negative feedback, tip moving, data processing and user interface. In this way, we fully exploit the potential of a personal computer in calculating and programming, enabling us to manipulate the scanning probe as required without any special digital control circuits and related technical know-how. This solution has been successfully applied to a homemade ultrahigh vacuum scanning tunneling microscope and a multiprobe scanning tunneling microscope.

  5. Pairagon+N-SCAN_EST: a model-based gene annotation pipeline

    DEFF Research Database (Denmark)

    Arumugam, Manimozhiyan; Wei, Chaochun; Brown, Randall H

    2006-01-01

    This paper describes Pairagon+N-SCAN_EST, a gene annotation pipeline that uses only native alignments. For each expressed sequence it chooses the best genomic alignment. Systems like ENSEMBL and ExoGean rely on trans alignments, in which expressed sequences are aligned to the genomic loci...... with de novo gene prediction by using N-SCAN_EST. N-SCAN_EST is based on a generalized HMM probability model augmented with a phylogenetic conservation model and EST alignments. It can predict complete transcripts by extending or merging EST alignments, but it can also predict genes in regions without EST...

  6. Estimating the chlorophyll content in the waters of Guanabara Bay from the LANDSAT multispectral scanning digital data

    Science.gov (United States)

    Dejesusparada, N. (Principal Investigator); Bentancurt, J. J. V.; Herz, B. R.; Molion, L. B.

    1980-01-01

    Detection of water quality in Guanabara Bay using multispectral scanning digital data taken from LANDSAT satellites was examined. To test these processes, an empirical (statistical) approach was choosen to observe the degree of relationship between LANDSAT data and the in situ data taken simultaneously. The linear and nonlinear regression analyses were taken from among those developed by INPE in 1978. Results indicate that the major regression was in the number six MSS band, atmospheric effects, which indicated a correction coefficient of 0.99 and an average error of 6.59 micrograms liter. This error was similar to that obtained in the laboratory. The chlorophyll content was between 0 and 100 micrograms/liter, as taken from the MSS of LANDSAT.

  7. A Technique for Digital Impression and Bite Registration for a Single Edentulous Arch.

    Science.gov (United States)

    Fang, Yiqin; Fang, Jing-Huan; Jeong, Seung-Mi; Choi, Byung-Ho

    2018-03-09

    Few studies have reported the application of digital technology for the process of impression and interocclusal recordings in edentulous patients. This article describes a digitizing system for generating digital edentulous models with a jaw relationship by taking direct digital impressions and a virtual bite registration using intraoral digital scanning. A specialized scan retractor was used to make digital impressions of edentulous jaws in patients' mouths using an intraoral scanner. Virtual bite registration was obtained with optical scanning of the buccal surfaces of both jaws at the occlusal vertical dimension. The registration was then used as a reference for aligning both jaws. Digital edentulous models that include the jaw relationship would be clinically beneficial for the fabrication of complete dentures in edentulous patients. © 2018 by the American College of Prosthodontists.

  8. Digital health and perioperative care.

    Science.gov (United States)

    Fotis, Theofanis

    2017-06-01

    According to the U.S. Food and Drug Administration 'the broad scope of digital health includes categories such as mobile health (mHealth), health information technology (IT), wearable devices, telehealth and telemedicine, and personalised medicine, and is used by providers and other stakeholders in their efforts to reduce inefficiencies, improve access, reduce costs, increase quality, and make medicine more personalised for patients (FDA 2016). More recently, Paul Sonier, a digital health strategist and founder of the Linkedin digital health group with more than 40,000 members, defined digital health as 'the convergence of the digital and genomic revolutions with health, healthcare, living, and society' (storyofdigitalhealth.com 2016). Copyright the Association for Perioperative Practice.

  9. A whole-genome scan in 164 Dutch sib pairs with attention-deficit/hyperactivity disorder : Suggestive evidence for linkage on chromosomes 7p and 15q

    NARCIS (Netherlands)

    Bakker, SC; van der Meulen, EM; Buitelaar, JK; Sandkuijl, LA; Pauls, DL; Monsuur, AJ; van't Slot, R; Minderaa, RB; Gunning, WB; Pearson, PL; Sinke, RJ

    A genome scan was performed on 164 Dutch affected sib pairs (ASPs) with attention-deficit/hyperactivity disorder (ADHD). All subjects were white and of Dutch descent and were phenotyped according to criteria set out in the Diagnostic and Statistical Manual Of Mental Disorders, 4th edition.

  10. Routine digital pathology workflow: The Catania experience

    Directory of Open Access Journals (Sweden)

    Filippo Fraggetta

    2017-01-01

    Full Text Available Introduction: Successful implementation of whole slide imaging (WSI for routine clinical practice has been accomplished in only a few pathology laboratories worldwide. We report the transition to an effective and complete digital surgical pathology workflow in the pathology laboratory at Cannizzaro Hospital in Catania, Italy. Methods: All (100% permanent histopathology glass slides were digitized at ×20 using Aperio AT2 scanners. Compatible stain and scanning slide racks were employed to streamline operations. eSlide Manager software was bidirectionally interfaced with the anatomic pathology laboratory information system. Virtual slide trays connected to the two-dimensional (2D barcode tracking system allowed pathologists to confirm that they were correctly assigned slides and that all tissues on these glass slides were scanned. Results: Over 115,000 glass slides were digitized with a scan fail rate of around 1%. Drying glass slides before scanning minimized them sticking to scanner racks. Implementation required introduction of a 2D barcode tracking system and modification of histology workflow processes. Conclusion: Our experience indicates that effective adoption of WSI for primary diagnostic use was more dependent on optimizing preimaging variables and integration with the laboratory information system than on information technology infrastructure and ensuring pathologist buy-in. Implementation of digital pathology for routine practice not only leveraged the benefits of digital imaging but also creates an opportunity for establishing standardization of workflow processes in the pathology laboratory.

  11. Radiographic film digitizing devices

    International Nuclear Information System (INIS)

    McFee, W.H.

    1988-01-01

    Until recently, all film digitizing devices for use with teleradiology or picture archiving and communication systems used a video camera to capture an image of the radiograph for subsequent digitization. The development of film digitizers that use a laser beam to scan the film represents a significant advancement in digital technology, resulting in improved image quality compared with video scanners. This paper discusses differences in resolution, efficiency, reliability, and the cost between these two types of devices. The results of a modified receiver operating characteristic comparison study of a video scanner and a laser scanner manufactured by the same company are also discussed

  12. Digital Materia

    OpenAIRE

    Lindgren, Marcus; Richey, Emma

    2014-01-01

    Med tankar från pedagogen Montessori och filosoferna Platon och Baudrillard har detta arbete behandlat frågor om datorn och dess betydelse för en grafiker. Frågeställningen formulerades efter hand och lydde tillslut: ”Hur kan materia te sig i digital form?” Forskningen resulterade i en hypotes för hur digital materia skulle födas i datorn: genom att blanda två uppsättningar av data, såsom två genuppsättningar tillsammans skapar en ny organism. Under produktionen utvecklades därmed en metod fö...

  13. Poaching Museum Collections using Digital 3D Technologies

    Directory of Open Access Journals (Sweden)

    Sarah Younan

    2015-12-01

    Full Text Available This paper investigates the creative engagement with digital 3D models of museum artefacts and gives insight into new uses of museum collections enabled by digital scanning, editing and 3D printing technologies. Digital 3D models of museum artefacts are malleable and increasingly easy to use. Additionally, freely available 3D software has made 3D scanning, editing and manufacturing possible for non-specialists. These technologies allow users to create new artworks through the creation and transformation of digital replicas of museum artefacts. Examples of creative works, taken from two case studies that involve the creative use of digital reproductions of museum artefacts are presented in this paper. These projects are illustrative of a larger trend: the digital ‘poaching’ of heritage artefacts. This paper examines how digital 3D technologies can foster creative forms of museum engagement, democratise access to museum collections and engage users with personal forms of museum experience.

  14. Allergic rhinitis - a total genome-scan for susceptibility genes suggests a locus on chromosome 4q24-q27

    DEFF Research Database (Denmark)

    Haagerup, A; Bjerke, T; Schøitz, P O

    2001-01-01

    Allergic rhinitis is a common disease of complex inheritance and is characterised by mucosal inflammation caused by allergen exposure. The genetics of closely related phenotypes such as asthma, atopy and to some extend atopic dermatitis has attracted attention in recent years. Genetic reports...... of allergic rhinitis on the contrary have as yet been most sparse. To identify candidate regions holding genes for allergic rhinitis we performed a total genome-scan on affected sib-pair families. From 100 Danish sib-pair families selected for allergy, families containing sib-pairs matching a phenotype...

  15. Sub-pixel analysis to support graphic security after scanning at low resolution

    Science.gov (United States)

    Haas, Bertrand; Cordery, Robert; Gou, Hongmei; Decker, Steve

    2006-02-01

    Whether in the domain of audio, video or finance, our world tends to become increasingly digital. However, for diverse reasons, the transition from analog to digital is often much extended in time, and proceeds by long steps (and sometimes never completes). One such step is the conversion of information on analog media to digital information. We focus in this paper on the conversion (scanning) of printed documents to digital images. Analog media have the advantage over digital channels that they can harbor much imperceptible information that can be used for fraud detection and forensic purposes. But this secondary information usually fails to be retrieved during the conversion step. This is particularly relevant since the Check-21 act (Check Clearing for the 21st Century act) became effective in 2004 and allows images of checks to be handled by banks as usual paper checks. We use here this situation of check scanning as our primary benchmark for graphic security features after scanning. We will first present a quick review of the most common graphic security features currently found on checks, with their specific purpose, qualities and disadvantages, and we demonstrate their poor survivability after scanning in the average scanning conditions expected from the Check-21 Act. We will then present a novel method of measurement of distances between and rotations of line elements in a scanned image: Based on an appropriate print model, we refine direct measurements to an accuracy beyond the size of a scanning pixel, so we can then determine expected distances, periodicity, sharpness and print quality of known characters, symbols and other graphic elements in a document image. Finally we will apply our method to fraud detection of documents after gray-scale scanning at 300dpi resolution. We show in particular that alterations on legitimate checks or copies of checks can be successfully detected by measuring with sub-pixel accuracy the irregularities inherently introduced

  16. The application of digital tomosynthesis to the diagnosis of the styloid process syndrome

    International Nuclear Information System (INIS)

    Ge Hequan; Zheng Kuihong; Wang Zijun; Huang Minhua; Ying Ligang

    2011-01-01

    Objective: To investigate the clinical value of digital tomosynthesis in the diagnosis of the styloid process syndrome. Methods: The thirty patients suspected of the styloid process syndrome underwent both multi-slice spiral CT scanning and digital tomosynthesis scanning. Two kinds of imaging were analyzed, and the length and angle of styloid on lateral and AP views were measured. Results: Both images could clearly show the styloid length, size, shape, direction and the relationship with surrounding structures. There was no significant difference in the length, medial angle in the AP position and anterior angle in the lateral position between multi-slice spiral CT scanning and digital tomosynthesis scanning (P>0.1). The styloid length on lateral digital tomosynthesis was significant smaller than that on multi-slice spiral CT scanning (P<0.01). Conclusions: The length of styloid measured should take the AP position as the standard using the digital tomosynthesis technique, which improve the image quality during the diagnosis of the styloid process syndrome and is less coitly and at a lower dose of radiation. Digital tomosynthesis could provide extensive clinical information and preoperative preparation of the very high referential value as CT canning. (authors)

  17. Using the gene ontology to scan multilevel gene sets for associations in genome wide association studies.

    Science.gov (United States)

    Schaid, Daniel J; Sinnwell, Jason P; Jenkins, Gregory D; McDonnell, Shannon K; Ingle, James N; Kubo, Michiaki; Goss, Paul E; Costantino, Joseph P; Wickerham, D Lawrence; Weinshilboum, Richard M

    2012-01-01

    Gene-set analyses have been widely used in gene expression studies, and some of the developed methods have been extended to genome wide association studies (GWAS). Yet, complications due to linkage disequilibrium (LD) among single nucleotide polymorphisms (SNPs), and variable numbers of SNPs per gene and genes per gene-set, have plagued current approaches, often leading to ad hoc "fixes." To overcome some of the current limitations, we developed a general approach to scan GWAS SNP data for both gene-level and gene-set analyses, building on score statistics for generalized linear models, and taking advantage of the directed acyclic graph structure of the gene ontology when creating gene-sets. However, other types of gene-set structures can be used, such as the popular Kyoto Encyclopedia of Genes and Genomes (KEGG). Our approach combines SNPs into genes, and genes into gene-sets, but assures that positive and negative effects of genes on a trait do not cancel. To control for multiple testing of many gene-sets, we use an efficient computational strategy that accounts for LD and provides accurate step-down adjusted P-values for each gene-set. Application of our methods to two different GWAS provide guidance on the potential strengths and weaknesses of our proposed gene-set analyses. © 2011 Wiley Periodicals, Inc.

  18. Digital karyotyping reveals probable target genes at 7q21.3 locus in hepatocellular carcinoma

    Directory of Open Access Journals (Sweden)

    Wang Shengyue

    2011-07-01

    Full Text Available Abstract Background Hepatocellular carcinoma (HCC is a worldwide malignant liver tumor with high incidence in China. Subchromosomal amplifications and deletions accounted for major genomic alterations occurred in HCC. Digital karyotyping was an effective method for analyzing genome-wide chromosomal aberrations at high resolution. Methods A digital karyotyping library of HCC was constructed and 454 Genome Sequencer FLX System (Roche was applied in large scale sequencing of the library. Digital Karyotyping Data Viewer software was used to analyze genomic amplifications and deletions. Genomic amplifications of genes detected by digital karyotyping were examined by real-time quantitative PCR. The mRNA expression level of these genes in tumorous and paired nontumorous tissues was also detected by real-time quantitative RT-PCR. Results A total of 821,252 genomic tags were obtained from the digital karyotyping library of HCC, with 529,162 tags (64% mapped to unique loci of human genome. Multiple subchromosomal amplifications and deletions were detected through analyzing the digital karyotyping data, among which the amplification of 7q21.3 drew our special attention. Validation of genes harbored within amplicons at 7q21.3 locus revealed that genomic amplification of SGCE, PEG10, DYNC1I1 and SLC25A13 occurred in 11 (21%, 11 (21%, 11 (21% and 23 (44% of the 52 HCC samples respectively. Furthermore, the mRNA expression level of SGCE, PEG10 and DYNC1I1 were significantly up-regulated in tumorous liver tissues compared with corresponding nontumorous counterparts. Conclusions Our results indicated that subchromosomal region of 7q21.3 was amplified in HCC, and SGCE, PEG10 and DYNC1I1 were probable protooncogenes located within the 7q21.3 locus.

  19. Digital radiographic techniques in the analysis of paintings

    International Nuclear Information System (INIS)

    James, A.E. Jr.; Gibbs, S.J.; James, A.E. III; Pickens, D.R.; Sloan, M.; Price, R.R.; Erickson, J.J.

    1985-01-01

    In this chapter the authors use the term digital radiography to mean any method of radiographic image production in which the silver halide-based film is replaced by an electronic sensor for production of an image. There are essentially three types of digital radiographic systems available at present, but others will be developed. These differ primarily in the method of image production and the rapidity with which images can be produced. The three methods discussed are digital fluoroscopy, scanned projection radiography, and the scanned point source radiography. Each has certain characteristics which, if properly utilized, will allow improved x-ray analysis of paintings

  20. Information Life-Cycle Management at the Erasmus Medical Center : Collaboratively Managing Digital Data for Care, Research, Education and the International Development of the GLOBE 3D Genome Viewer

    NARCIS (Netherlands)

    T.A. Knoch (Tobias); P. Walgemoed; H.J.F.M.M. Eussen (Bert)

    2006-01-01

    textabstractInformation Lifecycle Management at the Erasmus University Medical Centre. Collaboratively managing digital data for care, research and education using the international development of the GLOBE 3D Genome Viewer and Erasmus Computing Grid as catalyzing initiatives. The

  1. DIGITAL TERRAIN MODELS FROM MOBILE LASER SCANNING DATA IN MORAVIAN KARST

    Directory of Open Access Journals (Sweden)

    N. Tyagur

    2016-06-01

    Full Text Available During the last ten years, mobile laser scanning (MLS systems have become a very popular and efficient technology for capturing reality in 3D. A 3D laser scanner mounted on the top of a moving vehicle (e.g. car allows the high precision capturing of the environment in a fast way. Mostly this technology is used in cities for capturing roads and buildings facades to create 3D city models. In our work, we used an MLS system in Moravian Karst, which is a protected nature reserve in the Eastern Part of the Czech Republic, with a steep rocky terrain covered by forests. For the 3D data collection, the Riegl VMX 450, mounted on a car, was used with integrated IMU/GNSS equipment, which provides low noise, rich and very dense 3D point clouds. The aim of this work is to create a digital terrain model (DTM from several MLS data sets acquired in the neighbourhood of a road. The total length of two covered areas is 3.9 and 6.1 km respectively, with an average width of 100 m. For the DTM generation, a fully automatic, robust, hierarchic approach was applied. The derivation of the DTM is based on combinations of hierarchical interpolation and robust filtering for different resolution levels. For the generation of the final DTMs, different interpolation algorithms are applied to the classified terrain points. The used parameters were determined by explorative analysis. All MLS data sets were processed with one parameter set. As a result, a high precise DTM was derived with high spatial resolution of 0.25 x 0.25 m. The quality of the DTMs was checked by geodetic measurements and visual comparison with raw point clouds. The high quality of the derived DTM can be used for analysing terrain changes and morphological structures. Finally, the derived DTM was compared with the DTM of the Czech Republic (DMR 4G with a resolution of 5 x 5 m, which was created from airborne laser scanning data. The vertical accuracy of the derived DTMs is around 0.10 m.

  2. Electronically-Scanned Pressure Sensors

    Science.gov (United States)

    Coe, C. F.; Parra, G. T.; Kauffman, R. C.

    1984-01-01

    Sensors not pneumatically switched. Electronic pressure-transducer scanning system constructed in modular form. Pressure transducer modules and analog to digital converter module small enough to fit within cavities of average-sized wind-tunnel models. All switching done electronically. Temperature controlled environment maintained within sensor modules so accuracy maintained while ambient temperature varies.

  3. Image quality in digital radiography

    International Nuclear Information System (INIS)

    Kuhn, H.

    1986-01-01

    The contribution deals with the potentials of digital radiography and critically evaluates the advantages of drawbacks of the image intensifier-tv-digital system; digitalisation of the X-ray film and scanning of luminescent storage foils. The evaluation is done in comparison with the image quality of the traditional, large-size X-ray picture. (orig.) [de

  4. Decreasing medication turnaround time with digital scanning technology in a canadian health region.

    Science.gov (United States)

    Neville, Heather; Nodwell, Lisa; Alsharif, Sahar

    2014-11-01

    Reducing medication turnaround time can improve efficiency, patient safety, and quality of care in the hospital setting. Digital scanning technology (DST) can be used to electronically transmit scanned prescriber orders to a pharmacy computer queue for verification and processing, which may help to improve medication turnaround time. To evaluate medication turnaround time before and after implementation of DST for all medications and for antibiotics only. Medication turnaround times were evaluated retrospectively for periods before (June 6-10, 2011) and after (September 26-30, 2011) implementation of DST at 2 hospital sites in 1 health region. Medication turnaround time was defined as the time from composition of a medication order by the prescriber to its verification by the pharmacy (phase 1) and the time from prescriber composition to administration to the patient by a nurse (total). Median turnaround times were analyzed with SPSS software using the Mann-Whitney U test. In total, 304 and 244 medication orders were audited before and after DST implementation, respectively. Median phase 1 turnaround time for all medications declined significantly, from 2 h 23 min before DST implementation to 1 h 33 min after DST implementation (p < 0.001). Antibiotics were also processed significantly faster (1 h 51 min versus 1 h 9 min, p = 0.015). However, total turnaround time for all medications did not differ significantly (5 h 15 min versus 5 h 0 min, p = 0.42). Implementation of DST was associated with a 50-min decrease in medication turnaround time for the period from when an order was prescribed to the time it was processed by the pharmacy. Regular evaluation of medication turnaround times is recommended to compare with benchmarks, to ensure that hospital standards are being met, and to measure the effects of policy changes and implementation of new technology on medication-use processes.

  5. Curve Digitizer – A software for multiple curves digitizing

    Directory of Open Access Journals (Sweden)

    Florentin ŞPERLEA

    2010-06-01

    Full Text Available The Curve Digitizer is software that extracts data from an image file representing a graphicand returns them as pairs of numbers which can then be used for further analysis and applications.Numbers can be read on a computer screen stored in files or copied on paper. The final result is adata set that can be used with other tools such as MSEXCEL. Curve Digitizer provides a useful toolfor any researcher or engineer interested in quantifying the data displayed graphically. The image filecan be obtained by scanning a document

  6. Image processing techniques for digital orthophotoquad production

    Science.gov (United States)

    Hood, Joy J.; Ladner, L. J.; Champion, Richard A.

    1989-01-01

    Orthophotographs have long been recognized for their value as supplements or alternatives to standard maps. Recent trends towards digital cartography have resulted in efforts by the US Geological Survey to develop a digital orthophotoquad production system. Digital image files were created by scanning color infrared photographs on a microdensitometer. Rectification techniques were applied to remove tile and relief displacement, thereby creating digital orthophotos. Image mosaicking software was then used to join the rectified images, producing digital orthophotos in quadrangle format.

  7. A genome scan conducted in a multigenerational pedigree with convergent strabismus supports a complex genetic determinism.

    Directory of Open Access Journals (Sweden)

    Anouk Georges

    Full Text Available A genome-wide linkage scan was conducted in a Northern-European multigenerational pedigree with nine of 40 related members affected with concomitant strabismus. Twenty-seven members of the pedigree including all affected individuals were genotyped using a SNP array interrogating > 300,000 common SNPs. We conducted parametric and non-parametric linkage analyses assuming segregation of an autosomal dominant mutation, yet allowing for incomplete penetrance and phenocopies. We detected two chromosome regions with near-suggestive evidence for linkage, respectively on chromosomes 8 and 18. The chromosome 8 linkage implied a penetrance of 0.80 and a rate of phenocopy of 0.11, while the chromosome 18 linkage implied a penetrance of 0.64 and a rate of phenocopy of 0. Our analysis excludes a simple genetic determinism of strabismus in this pedigree.

  8. A genome scan conducted in a multigenerational pedigree with convergent strabismus supports a complex genetic determinism.

    Science.gov (United States)

    Georges, Anouk; Cambisano, Nadine; Ahariz, Naïma; Karim, Latifa; Georges, Michel

    2013-01-01

    A genome-wide linkage scan was conducted in a Northern-European multigenerational pedigree with nine of 40 related members affected with concomitant strabismus. Twenty-seven members of the pedigree including all affected individuals were genotyped using a SNP array interrogating > 300,000 common SNPs. We conducted parametric and non-parametric linkage analyses assuming segregation of an autosomal dominant mutation, yet allowing for incomplete penetrance and phenocopies. We detected two chromosome regions with near-suggestive evidence for linkage, respectively on chromosomes 8 and 18. The chromosome 8 linkage implied a penetrance of 0.80 and a rate of phenocopy of 0.11, while the chromosome 18 linkage implied a penetrance of 0.64 and a rate of phenocopy of 0. Our analysis excludes a simple genetic determinism of strabismus in this pedigree.

  9. The along track scanning radiometer for ERS-1 - Scan geometry and data simulation

    Science.gov (United States)

    Prata, A. J. Fred; Cechet, Robert P.; Barton, Ian J.; Llewellyn-Jones, David T.

    1990-01-01

    The first European remote-sensing satellite (ERS-1), due to be launched in 1990, will carry the along track scanning radiometer (ATSR), which has been specifically designed to give accurate satellite measurements of sea surface temperature (SST). Details of the novel scanning technique used by the ATSR are given, and data from the NOAA-9 AVHRR instrument are used to simulate raw ATSR imagery. Because of the high precision of the onboard blackbodies, the active cooling of the detectors, 12-b digitization, and dual-angle capability, the ATSR promises to achieve higher-accuracy satellite-derived SSTs than are currently available.

  10. Fast-scan em with digital image processing for dynamic experiments

    Science.gov (United States)

    Charles W. McMillin; Fred C. Billingsley; Robert E. Frazer

    1973-01-01

    The recent introduction of accessory instrumentation capable of display at television scan rates suggests a broadened application for the scanning electron microscope - the direct observation of motion (dynamic events) at magnifactions otherwise unattainable. In one illustrative experiment, the transverse surface of southern pine was observed when subjected to large...

  11. Beyond the Scanned Image: A Needs Assessment of Scholarly Users of Digital Collections

    Science.gov (United States)

    Green, Harriett E.; Courtney, Angela

    2015-01-01

    This paper presents an analysis of how humanities scholars use digital collections in their research and the ways in which digital collections could be enhanced for scholarly use. The authors surveyed and interviewed humanities faculty from twelve research universities about their research practices with digital collections and present analysis of…

  12. Genome-wide scan of 29,141 African Americans finds no evidence of directional selection since admixture.

    Science.gov (United States)

    Bhatia, Gaurav; Tandon, Arti; Patterson, Nick; Aldrich, Melinda C; Ambrosone, Christine B; Amos, Christopher; Bandera, Elisa V; Berndt, Sonja I; Bernstein, Leslie; Blot, William J; Bock, Cathryn H; Caporaso, Neil; Casey, Graham; Deming, Sandra L; Diver, W Ryan; Gapstur, Susan M; Gillanders, Elizabeth M; Harris, Curtis C; Henderson, Brian E; Ingles, Sue A; Isaacs, William; De Jager, Phillip L; John, Esther M; Kittles, Rick A; Larkin, Emma; McNeill, Lorna H; Millikan, Robert C; Murphy, Adam; Neslund-Dudas, Christine; Nyante, Sarah; Press, Michael F; Rodriguez-Gil, Jorge L; Rybicki, Benjamin A; Schwartz, Ann G; Signorello, Lisa B; Spitz, Margaret; Strom, Sara S; Tucker, Margaret A; Wiencke, John K; Witte, John S; Wu, Xifeng; Yamamura, Yuko; Zanetti, Krista A; Zheng, Wei; Ziegler, Regina G; Chanock, Stephen J; Haiman, Christopher A; Reich, David; Price, Alkes L

    2014-10-02

    The extent of recent selection in admixed populations is currently an unresolved question. We scanned the genomes of 29,141 African Americans and failed to find any genome-wide-significant deviations in local ancestry, indicating no evidence of selection influencing ancestry after admixture. A recent analysis of data from 1,890 African Americans reported that there was evidence of selection in African Americans after their ancestors left Africa, both before and after admixture. Selection after admixture was reported on the basis of deviations in local ancestry, and selection before admixture was reported on the basis of allele-frequency differences between African Americans and African populations. The local-ancestry deviations reported by the previous study did not replicate in our very large sample, and we show that such deviations were expected purely by chance, given the number of hypotheses tested. We further show that the previous study's conclusion of selection in African Americans before admixture is also subject to doubt. This is because the FST statistics they used were inflated and because true signals of unusual allele-frequency differences between African Americans and African populations would be best explained by selection that occurred in Africa prior to migration to the Americas. Copyright © 2014 The American Society of Human Genetics. Published by Elsevier Inc. All rights reserved.

  13. Digital radiography in NDT applications

    International Nuclear Information System (INIS)

    Deprins, E.

    2004-01-01

    A lot of film radiography could be replaced by today's technologies in the field of digital radiography. Only few of these applications have indeed replaced film. The choice to go digital depends on cost, quality requirement, workflow and throughput. Digital images offer a lot of advantages in terms of image manipulation and workflow. But despite the many advantages, a lot of considerations are needed before someone can decide to convert his organization from conventional to digital radiography. This paper gives an overview of all different modalities that can be used in digital radiography with today's technologies, together with the experiences of the pioneers of digital radiography. Film Scanning, Computed Radiography and Digital Radiography by using of different kinds of flat panel detectors all have their specific application fields and customers. What is the status of the technology today, which advantages brings digital radiography, and which are the limitations radiographers have to consider when replacing film by digital systems. (author)

  14. Precision of intraoral digital dental impressions with iTero and extraoral digitization with the iTero and a model scanner.

    Science.gov (United States)

    Flügge, Tabea V; Schlager, Stefan; Nelson, Katja; Nahles, Susanne; Metzger, Marc C

    2013-09-01

    Digital impression devices are used alternatively to conventional impression techniques and materials. The aims of this study were to evaluate the precision of digital intraoral scanning under clinical conditions (iTero; Align Technologies, San Jose, Calif) and to compare it with the precision of extraoral digitization. One patient received 10 full-arch intraoral scans with the iTero and conventional impressions with a polyether impression material (Impregum Penta; 3M ESPE, Seefeld, Germany). Stone cast models manufactured from the impressions were digitized 10 times with an extraoral scanner (D250; 3Shape, Copenhagen, Denmark) and 10 times with the iTero. Virtual models provided by each method were roughly aligned, and the model edges were trimmed with cutting planes to create common borders (Rapidform XOR; Inus Technologies, Seoul, Korea). A second model alignment was then performed along the closest distances of the surfaces (Artec Studio software; Artec Group, Luxembourg, Luxembourg). To assess precision, deviations between corresponding models were compared. Repeated intraoral scanning was evaluated in group 1, repeated extraoral model scanning with the iTero was assessed in group 2, and repeated model scanning with the D250 was assessed in group 3. Deviations between models were measured and expressed as maximums, means, medians, and root mean square errors for quantitative analysis. Color-coded displays of the deviations allowed qualitative visualization of the deviations. The greatest deviations and therefore the lowest precision were in group 1, with mean deviations of 50 μm, median deviations of 37 μm, and root mean square errors of 73 μm. Group 2 showed a higher precision, with mean deviations of 25 μm, median deviations of 18 μm, and root mean square errors of 51 μm. Scanning with the D250 had the highest precision, with mean deviations of 10 μm, median deviations of 5 μm, and root mean square errors of 20 μm. Intraoral and extraoral scanning

  15. DETECTING SELECTION IN NATURAL POPULATIONS: MAKING SENSE OF GENOME SCANS AND TOWARDS ALTERNATIVE SOLUTIONS

    Science.gov (United States)

    Haasl, Ryan J.; Payseur, Bret A.

    2016-01-01

    Genomewide scans for natural selection (GWSS) have become increasingly common over the last 15 years due to increased availability of genome-scale genetic data. Here, we report a representative survey of GWSS from 1999 to present and find that (i) between 1999 and 2009, 35 of 49 (71%) GWSS focused on human, while from 2010 to present, only 38 of 83 (46%) of GWSS focused on human, indicating increased focus on nonmodel organisms; (ii) the large majority of GWSS incorporate interpopulation or interspecific comparisons using, for example FST, cross-population extended haplotype homozygosity or the ratio of nonsynonymous to synonymous substitutions; (iii) most GWSS focus on detection of directional selection rather than other modes such as balancing selection; and (iv) in human GWSS, there is a clear shift after 2004 from microsatellite markers to dense SNP data. A survey of GWSS meant to identify loci positively selected in response to severe hypoxic conditions support an approach to GWSS in which a list of a priori candidate genes based on potential selective pressures are used to filter the list of significant hits a posteriori. We also discuss four frequently ignored determinants of genomic heterogeneity that complicate GWSS: mutation, recombination, selection and the genetic architecture of adaptive traits. We recommend that GWSS methodology should better incorporate aspects of genomewide heterogeneity using empirical estimates of relevant parameters and/or realistic, whole-chromosome simulations to improve interpretation of GWSS results. Finally, we argue that knowledge of potential selective agents improves interpretation of GWSS results and that new methods focused on correlations between environmental variables and genetic variation can help automate this approach. PMID:26224644

  16. 3D digital image processing for biofilm quantification from confocal laser scanning microscopy: Multidimensional statistical analysis of biofilm modeling

    Science.gov (United States)

    Zielinski, Jerzy S.

    The dramatic increase in number and volume of digital images produced in medical diagnostics, and the escalating demand for rapid access to these relevant medical data, along with the need for interpretation and retrieval has become of paramount importance to a modern healthcare system. Therefore, there is an ever growing need for processed, interpreted and saved images of various types. Due to the high cost and unreliability of human-dependent image analysis, it is necessary to develop an automated method for feature extraction, using sophisticated mathematical algorithms and reasoning. This work is focused on digital image signal processing of biological and biomedical data in one- two- and three-dimensional space. Methods and algorithms presented in this work were used to acquire data from genomic sequences, breast cancer, and biofilm images. One-dimensional analysis was applied to DNA sequences which were presented as a non-stationary sequence and modeled by a time-dependent autoregressive moving average (TD-ARMA) model. Two-dimensional analyses used 2D-ARMA model and applied it to detect breast cancer from x-ray mammograms or ultrasound images. Three-dimensional detection and classification techniques were applied to biofilm images acquired using confocal laser scanning microscopy. Modern medical images are geometrically arranged arrays of data. The broadening scope of imaging as a way to organize our observations of the biophysical world has led to a dramatic increase in our ability to apply new processing techniques and to combine multiple channels of data into sophisticated and complex mathematical models of physiological function and dysfunction. With explosion of the amount of data produced in a field of biomedicine, it is crucial to be able to construct accurate mathematical models of the data at hand. Two main purposes of signal modeling are: data size conservation and parameter extraction. Specifically, in biomedical imaging we have four key problems

  17. USGS 24k Digital Raster Graphic (DRG) Metadata

    Data.gov (United States)

    Minnesota Department of Natural Resources — Metadata for the scanned USGS 24k Topograpic Map Series (also known as 24k Digital Raster Graphic). Each scanned map is represented by a polygon in the layer and the...

  18. The boundary-scan handbook

    CERN Document Server

    Parker, Kenneth P

    2016-01-01

    Aimed at electronics industry professionals, this 4th edition of the Boundary Scan Handbook describes recent changes to the IEEE1149.1 Standard Test Access Port and Boundary-Scan Architecture. This updated edition features new chapters on the possible effects of the changes on the work of the practicing test engineers and the new 1149.8.1 standard. Anyone needing to understand the basics of boundary scan and its practical industrial implementation will need this book. Provides an overview of the recent changes to the 1149.1 standard and the effect of the changes on the work of test engineers;   Explains the new IEEE 1149.8.1 subsidiary standard and applications;   Describes the latest updates on the supplementary IEEE testing standards. In particular, addresses: IEEE Std 1149.1                      Digital Boundary-Scan IEEE Std 1149.4                      Analog Boundary-Scan IEEE Std 1149.6                      Advanced I/O Testing IEEE Std 1149.8.1           �...

  19. A fast DSP-based calorimeter hit scanning system

    International Nuclear Information System (INIS)

    Sekikawa, S.; Arai, I.; Suzuki, A.; Watanabe, A.; Marlow, D.R.; Mindas, C.R.; Wixted, R.L.

    1997-01-01

    A custom made digital signal processor (DSP) based system has been developed to scan calorimeter hits read by a 32-channel FASTBUS waveform recorder board. The scanner system identifies hit calorimeter elements by surveying their discriminated outputs. This information is used to generate a list of addresses, which guides the read-out process. The system is described and measurements of the scan times are given. (orig.)

  20. Digital archaeology field recording in the 4th dimension: ArchField C++ a 4D GIS for digital field work

    KAUST Repository

    Smith, Neil; Howland, Matthew; Levy, Thomas E.

    2016-01-01

    With the rapid adoption of laser scanning and photogrammetry among the archaeological community the creation of point cloud `data scaffolds' and digital documentation of archaeological sites is now becoming common. In field excavations, however, the continual exposure of archaeological layers requires a digital toolset in which to record, categorize and spatially locate artifacts, installations, and loci within a site's daily 3D or aerial scan. We present ArchField C++, the latest version of our digital field recording software that enables real-time digital GIS 3D Top Plan production within a rendering engine designed for visualizing massive 3D datasets. ArchField directly connects to Total Stations and our RTK GPS units to record sub-centimeter measurements for artifacts, scanning markers, loci boundaries, and camera positions. The processing pipeline enables the generation of publishable orthographic and perspective maps from the first day of excavation to the last. As a backend it uses a PostGIS database and the ability to export and import various vector, raster, DEM and 3D datasets that can be hosted by on-line geo-referenced databases. We present the application of ArchField C++ to our 2014 field excavations of the early Iron Age site of Khirbat al-Jariyah located in Southern Jordan.

  1. Digital archaeology field recording in the 4th dimension: ArchField C++ a 4D GIS for digital field work

    KAUST Repository

    Smith, Neil

    2016-02-25

    With the rapid adoption of laser scanning and photogrammetry among the archaeological community the creation of point cloud `data scaffolds\\' and digital documentation of archaeological sites is now becoming common. In field excavations, however, the continual exposure of archaeological layers requires a digital toolset in which to record, categorize and spatially locate artifacts, installations, and loci within a site\\'s daily 3D or aerial scan. We present ArchField C++, the latest version of our digital field recording software that enables real-time digital GIS 3D Top Plan production within a rendering engine designed for visualizing massive 3D datasets. ArchField directly connects to Total Stations and our RTK GPS units to record sub-centimeter measurements for artifacts, scanning markers, loci boundaries, and camera positions. The processing pipeline enables the generation of publishable orthographic and perspective maps from the first day of excavation to the last. As a backend it uses a PostGIS database and the ability to export and import various vector, raster, DEM and 3D datasets that can be hosted by on-line geo-referenced databases. We present the application of ArchField C++ to our 2014 field excavations of the early Iron Age site of Khirbat al-Jariyah located in Southern Jordan.

  2. Meta-analysis of genome-wide scans for human adult stature identifies novel Loci and associations with measures of skeletal frame size.

    Directory of Open Access Journals (Sweden)

    Nicole Soranzo

    2009-04-01

    Full Text Available Recent genome-wide (GW scans have identified several independent loci affecting human stature, but their contribution through the different skeletal components of height is still poorly understood. We carried out a genome-wide scan in 12,611 participants, followed by replication in an additional 7,187 individuals, and identified 17 genomic regions with GW-significant association with height. Of these, two are entirely novel (rs11809207 in CATSPER4, combined P-value = 6.1x10(-8 and rs910316 in TMED10, P-value = 1.4x10(-7 and two had previously been described with weak statistical support (rs10472828 in NPR3, P-value = 3x10(-7 and rs849141 in JAZF1, P-value = 3.2x10(-11. One locus (rs1182188 at GNA12 identifies the first height eQTL. We also assessed the contribution of height loci to the upper- (trunk and lower-body (hip axis and femur skeletal components of height. We find evidence for several loci associated with trunk length (including rs6570507 in GPR126, P-value = 4x10(-5 and rs6817306 in LCORL, P-value = 4x10(-4, hip axis length (including rs6830062 at LCORL, P-value = 4.8x10(-4 and rs4911494 at UQCC, P-value = 1.9x10(-4, and femur length (including rs710841 at PRKG2, P-value = 2.4x10(-5 and rs10946808 at HIST1H1D, P-value = 6.4x10(-6. Finally, we used conditional analyses to explore a possible differential contribution of the height loci to these different skeletal size measurements. In addition to validating four novel loci controlling adult stature, our study represents the first effort to assess the contribution of genetic loci to three skeletal components of height. Further statistical tests in larger numbers of individuals will be required to verify if the height loci affect height preferentially through these subcomponents of height.

  3. The Use of Central Pathology Review With Digital Slide Scanning in Advanced-stage Mycosis Fungoides and Sézary Syndrome: A Multi-institutional and International Pathology Study.

    Science.gov (United States)

    Gru, Alejandro A; Kim, Jinah; Pulitzer, Melissa; Guitart, Joan; Battistella, Maxime; Wood, Gary S; Cerroni, Lorenzo; Kempf, Werner; Willemze, Rein; Pawade, Joya; Querfeld, Christiane; Schaffer, Andras; Pincus, Laura; Tetzlaff, Michael; Duvic, Madeleine; Scarisbrick, Julia; Porcu, Pierluigi; Mangold, Aaron R; DiCaudo, David J; Shinohara, Michi; Hong, Eric K; Horton, Bethany; Kim, Youn H

    2018-06-01

    This pathology PILOT study aims to define the role and feasibility of centralized pathology review in a cohort of 75 patients from different centers in the United States and Europe using digital slide scanning. The pathologic material from 75 patients who had been diagnosed with mycosis fungoides/Sézary syndrome and were clinically staged as IIb or above was retrieved from 11 participating centers. Each pathology reviewer was provided with the pathologic diagnosis (by the referring pathologist), and the following list of histopathologic criteria (presence or absence) from the initial report: epidermotropism, folliculotropism (FT), large cell transformation, syringotropism, and granulomas. Patients with advance stage were selected for this study as this is a population where there is significant variability in the diagnosis of pathologic prognostic and predictive biomarkers. The slides were digitally scanned with an Aperio scanner and consensus review of cases occurred when major or minor discrepancies between the referral diagnosis and central pathology review occurred. Among the 75 cases, 70 (93.3%) had a final consensus diagnosis between the 3 central review pathologists. The overall agreement between the consensus review and the referring pathologist was 60%. The overall agreement was also higher between the reviewers and consensus review, compared with the referring pathologist and consensus. 65.3% of cases had some type of discrepancy (major or minor) between the outside and consensus review. Major discrepancies were seen in 34 of 73 cases (46.6%; 73 cases indicated a yes or no response). Minor discrepancies were seen in 32 of 75 (42.7%) of cases. Most of the major discrepancies were accounted by a difference in interpretation in the presence or absence of large cell transformation or FT. Most minor discrepancies were explained by a different interpretation in the expression of CD30. We found digital slide scanning to be a beneficial, reliable, and practical

  4. Digital breast tomosynthesis: observer performance of clustered microcalcification detection on breast phantom images acquired with an experimental system using variable scan angles, angular increments, and number of projection views.

    Science.gov (United States)

    Chan, Heang-Ping; Goodsitt, Mitchell M; Helvie, Mark A; Zelakiewicz, Scott; Schmitz, Andrea; Noroozian, Mitra; Paramagul, Chintana; Roubidoux, Marilyn A; Nees, Alexis V; Neal, Colleen H; Carson, Paul; Lu, Yao; Hadjiiski, Lubomir; Wei, Jun

    2014-12-01

    To investigate the dependence of microcalcification cluster detectability on tomographic scan angle, angular increment, and number of projection views acquired at digital breast tomosynthesis ( DBT digital breast tomosynthesis ). A prototype DBT digital breast tomosynthesis system operated in step-and-shoot mode was used to image breast phantoms. Four 5-cm-thick phantoms embedded with 81 simulated microcalcification clusters of three speck sizes (subtle, medium, and obvious) were imaged by using a rhodium target and rhodium filter with 29 kV, 50 mAs, and seven acquisition protocols. Fixed angular increments were used in four protocols (denoted as scan angle, angular increment, and number of projection views, respectively: 16°, 1°, and 17; 24°, 3°, and nine; 30°, 3°, and 11; and 60°, 3°, and 21), and variable increments were used in three (40°, variable, and 13; 40°, variable, and 15; and 60°, variable, and 21). The reconstructed DBT digital breast tomosynthesis images were interpreted by six radiologists who located the microcalcification clusters and rated their conspicuity. The mean sensitivity for detection of subtle clusters ranged from 80% (22.5 of 28) to 96% (26.8 of 28) for the seven DBT digital breast tomosynthesis protocols; the highest sensitivity was achieved with the 16°, 1°, and 17 protocol (96%), but the difference was significant only for the 60°, 3°, and 21 protocol (80%, P .99). The conspicuity of subtle and medium clusters with the 16°, 1°, and 17 protocol was rated higher than those with other protocols; the differences were significant for subtle clusters with the 24°, 3°, and nine protocol and for medium clusters with 24°, 3°, and nine; 30°, 3°, and 11; 60°, 3° and 21; and 60°, variable, and 21 protocols (P tomosynthesis provided higher sensitivity and conspicuity than wide-angle DBT digital breast tomosynthesis for subtle microcalcification clusters. © RSNA, 2014.

  5. Navigating the Interface Between Landscape Genetics and Landscape Genomics

    Directory of Open Access Journals (Sweden)

    Andrew Storfer

    2018-03-01

    Full Text Available As next-generation sequencing data become increasingly available for non-model organisms, a shift has occurred in the focus of studies of the geographic distribution of genetic variation. Whereas landscape genetics studies primarily focus on testing the effects of landscape variables on gene flow and genetic population structure, landscape genomics studies focus on detecting candidate genes under selection that indicate possible local adaptation. Navigating the transition between landscape genomics and landscape genetics can be challenging. The number of molecular markers analyzed has shifted from what used to be a few dozen loci to thousands of loci and even full genomes. Although genome scale data can be separated into sets of neutral loci for analyses of gene flow and population structure and putative loci under selection for inference of local adaptation, there are inherent differences in the questions that are addressed in the two study frameworks. We discuss these differences and their implications for study design, marker choice and downstream analysis methods. Similar to the rapid proliferation of analysis methods in the early development of landscape genetics, new analytical methods for detection of selection in landscape genomics studies are burgeoning. We focus on genome scan methods for detection of selection, and in particular, outlier differentiation methods and genetic-environment association tests because they are the most widely used. Use of genome scan methods requires an understanding of the potential mismatches between the biology of a species and assumptions inherent in analytical methods used, which can lead to high false positive rates of detected loci under selection. Key to choosing appropriate genome scan methods is an understanding of the underlying demographic structure of study populations, and such data can be obtained using neutral loci from the generated genome-wide data or prior knowledge of a species

  6. Efficient digitalization method for dental restorations using micro-CT data.

    Science.gov (United States)

    Kim, Changhwan; Baek, Seung Hoon; Lee, Taewon; Go, Jonggun; Kim, Sun Young; Cho, Seungryong

    2017-03-15

    The objective of this study was to demonstrate the feasibility of using micro-CT scan of dental impressions for fabricating dental restorations and to compare the dimensional accuracy of dental models generated from various methods. The key idea of the proposed protocol is that dental impression of patients can be accurately digitized by micro-CT scan and that one can make digital cast model from micro-CT data directly. As air regions of the micro-CT scan data of dental impression are equivalent to the real teeth and surrounding structures, one can segment the air regions and fabricate digital cast model in the STL format out of them. The proposed method was validated by a phantom study using a typodont with prepared teeth. Actual measurement and deviation map analysis were performed after acquiring digital cast models for each restoration methods. Comparisons of the milled restorations were also performed by placing them on the prepared teeth of typodont. The results demonstrated that an efficient fabrication of precise dental restoration is achievable by use of the proposed method.

  7. Efficient digitalization method for dental restorations using micro-CT data

    Science.gov (United States)

    Kim, Changhwan; Baek, Seung Hoon; Lee, Taewon; Go, Jonggun; Kim, Sun Young; Cho, Seungryong

    2017-03-01

    The objective of this study was to demonstrate the feasibility of using micro-CT scan of dental impressions for fabricating dental restorations and to compare the dimensional accuracy of dental models generated from various methods. The key idea of the proposed protocol is that dental impression of patients can be accurately digitized by micro-CT scan and that one can make digital cast model from micro-CT data directly. As air regions of the micro-CT scan data of dental impression are equivalent to the real teeth and surrounding structures, one can segment the air regions and fabricate digital cast model in the STL format out of them. The proposed method was validated by a phantom study using a typodont with prepared teeth. Actual measurement and deviation map analysis were performed after acquiring digital cast models for each restoration methods. Comparisons of the milled restorations were also performed by placing them on the prepared teeth of typodont. The results demonstrated that an efficient fabrication of precise dental restoration is achievable by use of the proposed method.

  8. Digital Raster Graphics (DRG) Lambert

    Data.gov (United States)

    Kansas Data Access and Support Center — The Digital Raster Graphic-Lambert (DRG-Lam) is a raster image of a scanned USGS topographic map with the collar information clipped out, georeferenced to the...

  9. Digital Position Encoding Of Galvanometer Scanner In A Laser Microscope

    Science.gov (United States)

    Liljeborg, Anders

    1988-09-01

    An account is given of a realization of a feedback method to digitize the analog position signal from a moving iron galvanometer. It is employed in a confocal scanning laser microscope for generating digital images. The photometric sampling has to be closely coupled to the position of a mirror that scans a focused laser beam across a microscope specimen. Pictures with low geometric distortion are obtained up to the size 1024 x 1024 pixels.

  10. Evaluation of CBCT digital models and traditional models using the Little's Index.

    Science.gov (United States)

    Kau, Chung How; Littlefield, Jay; Rainy, Neal; Nguyen, Jennifer T; Creed, Ben

    2010-05-01

    To determine if measurements obtained from digital models from cone beam computed tomography (CBCT) images were comparable to the traditional method of digital study models by impressions. Digital models of 30 subjects were used. InVivoDental (Anatomage, San Jose, Calif) software was used to analyze CBCT scans taken by a Galileos cone beam scanner (Sirona, Charlotte, NC) with a field of view of 15 x 15 x 15 cm(3) and a voxel resolution of 0.125 mm. OrthoCAD (Cadent, Fairview, NJ) software was used to analyze impression scans of patients at different stages of orthodontic treatment. Impressions were taken using alginate and were mailed to OrthoCAD for digital conversion. The scans were then electronically returned in digital format for analysis. The maxillary mean scores for the Little's Index were 9.65 mm for digital models and 8.87 mm for InVivoDental models, respectively. The mandibular mean scores for the Little's Index were 6.41 mm for digital models and 6.27 mm for InVivoDental models, respectively. The mean overjet measurements were 3.32 mm for digital models and 3.52 mm for InVivoDental models, respectively. The overbite measurements were 2.29 mm for digital models and 2.26 mm for InVivoDental models, respectively. The paired t-test showed no statistical significance between the differences in all measurements. CBCT digital models are as accurate as OrthoCAD digital models in making linear measurements for overjet, overbite, and crowding measurements.

  11. 3D Digital Smile Design With a Mobile Phone and Intraoral Optical Scanner.

    Science.gov (United States)

    Daher, René; Ardu, Stefano; Vjero, Osela; Krejci, Ivo

    2018-06-01

    Extraoral facial scanning using a mobile phone has emerged as a viable, cost-effective option for certain applications not requiring high precision, such as patient education and 3-dimensional (3D) digital smile design. This technological development is particularly promising for general practitioners (GPs) who may not be able to invest in expensive,complex digital impressioning devices. This article describes and illustrates a relatively simple and accessible workflow that avails digital 3D facial scanning benefits to GPs.

  12. High resolution RGB color line scan camera

    Science.gov (United States)

    Lynch, Theodore E.; Huettig, Fred

    1998-04-01

    A color line scan camera family which is available with either 6000, 8000 or 10000 pixels/color channel, utilizes off-the-shelf lenses, interfaces with currently available frame grabbers, includes on-board pixel by pixel offset correction, and is configurable and controllable via RS232 serial port for computer controlled or stand alone operation is described in this paper. This line scan camera is based on an available 8000 element monochrome line scan camera designed by AOA for OEM use. The new color version includes improvements such as better packaging and additional user features which make the camera easier to use. The heart of the camera is a tri-linear CCD sensor with on-chip color balancing for maximum accuracy and pinned photodiodes for low lag response. Each color channel is digitized to 12 bits and all three channels are multiplexed together so that the resulting camera output video is either a 12 or 8 bit data stream at a rate of up to 24Megpixels/sec. Conversion from 12 to 8 bit, or user-defined gamma, is accomplished by on board user-defined video look up tables. The camera has two user-selectable operating modes; lows speed, high sensitivity mode or high speed, reduced sensitivity mode. The intended uses of the camera include industrial inspection, digital archiving, document scanning, and graphic arts applications.

  13. A Novel Methodology to Validate the Accuracy of Extraoral Dental Scanners and Digital Articulation Systems.

    Science.gov (United States)

    Ellakwa, A; Elnajar, S; Littlefair, D; Sara, G

    2018-05-03

    The aim of the current study is to develop a novel method to investigate the accuracy of 3D scanners and digital articulation systems. An upper and a lower poured stone model were created by taking impression of fully dentate male (fifty years old) participant. Titanium spheres were added to the models to allow for an easily recognisable geometric shape for measurement after scanning and digital articulation. Measurements were obtained using a Coordinate Measuring Machine to record volumetric error, articulation error and clinical effect error. Three scanners were compared, including the Imetric 3D iScan d104i, Shining 3D AutoScan-DS100 and 3Shape D800, as well as their respective digital articulation software packages. Stoneglass Industries PDC digital articulation system was also applied to the Imetric scans for comparison with the CMM measurements. All the scans displayed low volumetric error (p⟩0.05), indicating that the scanners themselves had a minor contribution to the articulation and clinical effect errors. The PDC digital articulation system was found to deliver the lowest average errors, with good repeatability of results. The new measuring technique in the current study was able to assess the scanning and articulation accuracy of the four systems investigated. The PDC digital articulation system using Imetric scans was recommended as it displayed the lowest articulation error and clinical effect error with good repeatability. The low errors from the PDC system may have been due to its use of a 3D axis for alignment rather than the use of a best fit. Copyright© 2018 Dennis Barber Ltd.

  14. Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Liu Xinming; Lai Chaojen; Chen Lingyun; Han Tao; Zhong Yuncheng; Shen Youtao; Wang Tianpeng; Shaw, Chris C [Department of Imaging Physics, Digital Imaging Research Laboratory, University of Texas M. D. Anderson Cancer Center, Houston, TX 77030-4009 (United States)], E-mail: xliu@di.mdacc.tmc.edu

    2009-11-21

    It is well recognized in projection radiography that low-contrast detectability suffers in heavily attenuating regions due to excessively low x-ray fluence to the image receptor and higher noise levels. Exposure equalization can improve image quality by increasing the x-ray exposure to heavily attenuating regions, resulting in a more uniform distribution of exposure to the detector. Image quality is also expected to be improved by using the slot-scan geometry to reject scattered radiation effectively without degrading primary x-rays. This paper describes the design of a prototype scan equalization digital radiography (SEDR) system implemented with an amorphous silicon (a-Si) thin-film transistor (TFT) array-based flat-panel detector. With this system, slot-scan geometry with alternate line erasure and readout (ALER) technique was used to achieve scatter rejection. A seven-segment beam height modulator assembly was mounted onto the fore collimator to regulate exposure regionally for chest radiography. The beam modulator assembly, consisting of micro linear motors, lead screw cartridge with lead (Pb) beam blockers attached, position feedback sensors and motor driver circuitry, has been tested and found to have an acceptable response for exposure equalization in chest radiography. An anthropomorphic chest phantom was imaged in the posterior-anterior (PA) view under clinical conditions. Scatter component, primary x-rays, scatter-to-primary ratios (SPRs) and primary signal-to-noise ratios (PSNRs) were measured in the SEDR images to evaluate the rejection and redistribution of scattered radiation, and compared with those for conventional full-field imaging with and without anti-scatter grid methods. SPR reduction ratios (SPRRRs, defined as the differences between the non-grid full-field SPRs and the reduced SPRs divided by the former) yielded approximately 59% for the full-field imaging with grid and 82% for the SEDR technique in the lungs, and 77% for the full

  15. prokaryote genome annotation with GeneScan and GLIMMER

    Indian Academy of Sciences (India)

    Unknown

    The number of false predictions (both positive and negative) is higher for GeneScan as compared to GLIMMER, but in a ... on whether they need to be trained on a set of genes in order to ..... FP has partial matches to the kdpA gene in C. jejuni.

  16. Digital radiology. Clinical experience

    Energy Technology Data Exchange (ETDEWEB)

    Stacul, F; Smathers, R L

    1985-01-01

    The authors report the experience achieved ad the Stanford University (USA) with a digital radiography system which allows the digitization of the film and of the images collected with photostimulable phophors. The phophor is essentially an intensifying screen where a latent image is stored after exposure to X-rays and is extracted by a laser scanning. The images collected with the digitized film and with the phophor (chest, breast, bone) have been analyzed. The digitized film offers potential diagnostic advantages over the conventional film, because of the contrast manipulation and many other processing options. The possibility to recover the information of overexposed films appears very attractive. The photostimulable phophors allow to get good quality images, with a consistent reduction of dose and costs. These plates offer the possibility, in the next future, to replace the conventional screen-film systems.

  17. A genome-wide scan for selection signatures in Nellore cattle.

    Science.gov (United States)

    Somavilla, A L; Sonstegard, T S; Higa, R H; Rosa, A N; Siqueira, F; Silva, L O C; Torres Júnior, R A A; Coutinho, L L; Mudadu, M A; Alencar, M M; Regitano, L C A

    2014-12-01

    Brazilian Nellore cattle (Bos indicus) have been selected for growth traits for over more than four decades. In recent years, reproductive and meat quality traits have become more important because of increasing consumption, exports and consumer demand. The identification of genome regions altered by artificial selection can potentially permit a better understanding of the biology of specific phenotypes that are useful for the development of tools designed to increase selection efficiency. Therefore, the aims of this study were to detect evidence of recent selection signatures in Nellore cattle using extended haplotype homozygosity methodology and BovineHD marker genotypes (>777,000 single nucleotide polymorphisms) as well as to identify corresponding genes underlying these signals. Thirty-one significant regions (P meat quality, fatty acid profiles and immunity. In addition, 545 genes were identified in regions harboring selection signatures. Within this group, 58 genes were associated with growth, muscle and adipose tissue metabolism, reproductive traits or the immune system. Using relative extended haplotype homozygosity to analyze high-density single nucleotide polymorphism marker data allowed for the identification of regions potentially under artificial selection pressure in the Nellore genome, which might be used to better understand autozygosity and the effects of selection on the Nellore genome. © 2014 Stichting International Foundation for Animal Genetics.

  18. Double-polarizating scanning radiometer

    International Nuclear Information System (INIS)

    Mishev, D.N.; Nazyrski, T.G.

    1986-01-01

    The double-polarizating single-channel scanning radiometer comprises the following serial connected parts: a scanning double-polarizating aerial, a block for polarization separation, a radiometer receiver, an analog-to-digit converter and an information flow forming block. The low frequency input of the radiometer receiver is connected with a control block, which is also connected with a first bus of a microprocessor, the second bus of which is connected with the A-D converter. The control input of the scanning double-polarizating aerial is connected with the first microprocessor bus. The control inputs of the block for polarization separation are linked by an electronic switch with the output of the forming block, the input of which is connected to the first input of the control block. The control inputs of the block for polarization separation are connected with the second and the third input of the information flow forming block. 2 cls

  19. An objective protocol for comparing the noise performance of silver halide film and digital sensor

    Science.gov (United States)

    Cao, Frédéric; Guichard, Frédéric; Hornung, Hervé; Tessière, Régis

    2012-01-01

    Digital sensors have obviously invaded the photography mass market. However, some photographers with very high expectancy still use silver halide film. Are they only nostalgic reluctant to technology or is there more than meets the eye? The answer is not so easy if we remark that, at the end of the golden age, films were actually scanned before development. Nowadays film users have adopted digital technology and scan their film to take advantage from digital processing afterwards. Therefore, it is legitimate to evaluate silver halide film "with a digital eye", with the assumption that processing can be applied as for a digital camera. The article will describe in details the operations we need to consider the film as a RAW digital sensor. In particular, we have to account for the film characteristic curve, the autocorrelation of the noise (related to film grain) and the sampling of the digital sensor (related to Bayer filter array). We also describe the protocol that was set, from shooting to scanning. We then present and interpret the results of sensor response, signal to noise ratio and dynamic range.

  20. The Prosthetic Workflow in the Digital Era

    Directory of Open Access Journals (Sweden)

    Lidia Tordiglione

    2016-01-01

    Full Text Available The purpose of this retrospective study was to clinically evaluate the benefits of adopting a full digital workflow for the implementation of fixed prosthetic restorations on natural teeth. To evaluate the effectiveness of these protocols, treatment plans were drawn up for 15 patients requiring rehabilitation of one or more natural teeth. All the dental impressions were taken using a Planmeca PlanScan® (Planmeca OY, Helsinki, Finland intraoral scanner, which provided digital casts on which the restorations were digitally designed using Exocad® (Exocad GmbH, Germany, 2010 software and fabricated by CAM processing on 5-axis milling machines. A total of 28 single crowns were made from monolithic zirconia, 12 vestibular veneers from lithium disilicate, and 4 three-quarter vestibular veneers with palatal extension. While the restorations were applied, the authors could clinically appreciate the excellent match between the digitally produced prosthetic design and the cemented prostheses, which never required any occlusal or proximal adjustment. Out of all the restorations applied, only one exhibited premature failure and was replaced with no other complications or need for further scanning. From the clinical experience gained using a full digital workflow, the authors can confirm that these work processes enable the fabrication of clinically reliable restorations, with all the benefits that digital methods bring to the dentist, the dental laboratory, and the patient.

  1. Frequency characteristics of the laser film digitizer

    International Nuclear Information System (INIS)

    Ishimitsu, Y.; Taira, R.K.; Huang, H.K.

    1988-01-01

    The frequency characteristics of the laser film digitizer in the parallel and in the perpendicular scan direction are different. Because of this difference, moire pattern artifacts may appear in the digitized image. The authors found that this phenomenon is due to the frequency transfer characteristics of the various components in the laser film digitizer. From this observation, they derive a relationship between the spatial frequency content of the original image and the laser beam spot size based on the concept of image contrast. This relationship can be utilized to avoid the appearance of the moire pattern in the digitized image

  2. A digital repository with an extensible data model for biobanking and genomic analysis management.

    Science.gov (United States)

    Izzo, Massimiliano; Mortola, Francesco; Arnulfo, Gabriele; Fato, Marco M; Varesio, Luigi

    2014-01-01

    Molecular biology laboratories require extensive metadata to improve data collection and analysis. The heterogeneity of the collected metadata grows as research is evolving in to international multi-disciplinary collaborations and increasing data sharing among institutions. Single standardization is not feasible and it becomes crucial to develop digital repositories with flexible and extensible data models, as in the case of modern integrated biobanks management. We developed a novel data model in JSON format to describe heterogeneous data in a generic biomedical science scenario. The model is built on two hierarchical entities: processes and events, roughly corresponding to research studies and analysis steps within a single study. A number of sequential events can be grouped in a process building up a hierarchical structure to track patient and sample history. Each event can produce new data. Data is described by a set of user-defined metadata, and may have one or more associated files. We integrated the model in a web based digital repository with a data grid storage to manage large data sets located in geographically distinct areas. We built a graphical interface that allows authorized users to define new data types dynamically, according to their requirements. Operators compose queries on metadata fields using a flexible search interface and run them on the database and on the grid. We applied the digital repository to the integrated management of samples, patients and medical history in the BIT-Gaslini biobank. The platform currently manages 1800 samples of over 900 patients. Microarray data from 150 analyses are stored on the grid storage and replicated on two physical resources for preservation. The system is equipped with data integration capabilities with other biobanks for worldwide information sharing. Our data model enables users to continuously define flexible, ad hoc, and loosely structured metadata, for information sharing in specific research

  3. Genome scan identifies a locus affecting gamma-globin expression in human beta-cluster YAC transgenic mice

    Energy Technology Data Exchange (ETDEWEB)

    Lin, S.D.; Cooper, P.; Fung, J.; Weier, H.U.G.; Rubin, E.M.

    2000-03-01

    Genetic factors affecting post-natal g-globin expression - a major modifier of the severity of both b-thalassemia and sickle cell anemia, have been difficult to study. This is especially so in mice, an organism lacking a globin gene with an expression pattern equivalent to that of human g-globin. To model the human b-cluster in mice, with the goal of screening for loci affecting human g-globin expression in vivo, we introduced a human b-globin cluster YAC transgene into the genome of FVB mice . The b-cluster contained a Greek hereditary persistence of fetal hemoglobin (HPFH) g allele resulting in postnatal expression of human g-globin in transgenic mice. The level of human g-globin for various F1 hybrids derived from crosses between the FVB transgenics and other inbred mouse strains was assessed. The g-globin level of the C3HeB/FVB transgenic mice was noted to be significantly elevated. To map genes affecting postnatal g-globin expression, a 20 centiMorgan (cM) genome scan of a C3HeB/F VB transgenics [prime] FVB backcross was performed, followed by high-resolution marker analysis of promising loci. From this analysis we mapped a locus within a 2.2 cM interval of mouse chromosome 1 at a LOD score of 4.2 that contributes 10.4% of variation in g-globin expression level. Combining transgenic modeling of the human b-globin gene cluster with quantitative trait analysis, we have identified and mapped a murine locus that impacts on human g-globin expression in vivo.

  4. Digitalization and networking of analog simulators and portal images.

    Science.gov (United States)

    Pesznyák, Csilla; Zaránd, Pál; Mayer, Arpád

    2007-03-01

    Many departments have analog simulators and irradiation facilities (especially cobalt units) without electronic portal imaging. Import of the images into the R&V (Record & Verify) system is required. Simulator images are grabbed while portal films scanned by using a laser scanner and both converted into DICOM RT (Digital Imaging and Communications in Medicine Radiotherapy) images. Image intensifier output of a simulator and portal films are converted to DICOM RT images and used in clinical practice. The simulator software was developed in cooperation at the authors' hospital. The digitalization of analog simulators is a valuable updating in clinical use replacing screen-film technique. Film scanning and digitalization permit the electronic archiving of films. Conversion into DICOM RT images is a precondition of importing to the R&V system.

  5. MutScan: fast detection and visualization of target mutations by scanning FASTQ data.

    Science.gov (United States)

    Chen, Shifu; Huang, Tanxiao; Wen, Tiexiang; Li, Hong; Xu, Mingyan; Gu, Jia

    2018-01-22

    Some types of clinical genetic tests, such as cancer testing using circulating tumor DNA (ctDNA), require sensitive detection of known target mutations. However, conventional next-generation sequencing (NGS) data analysis pipelines typically involve different steps of filtering, which may cause miss-detection of key mutations with low frequencies. Variant validation is also indicated for key mutations detected by bioinformatics pipelines. Typically, this process can be executed using alignment visualization tools such as IGV or GenomeBrowse. However, these tools are too heavy and therefore unsuitable for validating mutations in ultra-deep sequencing data. We developed MutScan to address problems of sensitive detection and efficient validation for target mutations. MutScan involves highly optimized string-searching algorithms, which can scan input FASTQ files to grab all reads that support target mutations. The collected supporting reads for each target mutation will be piled up and visualized using web technologies such as HTML and JavaScript. Algorithms such as rolling hash and bloom filter are applied to accelerate scanning and make MutScan applicable to detect or visualize target mutations in a very fast way. MutScan is a tool for the detection and visualization of target mutations by only scanning FASTQ raw data directly. Compared to conventional pipelines, this offers a very high performance, executing about 20 times faster, and offering maximal sensitivity since it can grab mutations with even one single supporting read. MutScan visualizes detected mutations by generating interactive pile-ups using web technologies. These can serve to validate target mutations, thus avoiding false positives. Furthermore, MutScan can visualize all mutation records in a VCF file to HTML pages for cloud-friendly VCF validation. MutScan is an open source tool available at GitHub: https://github.com/OpenGene/MutScan.

  6. Genomic characterization reconfirms the taxonomic status of Lactobacillus parakefiri

    Science.gov (United States)

    TANIZAWA, Yasuhiro; KOBAYASHI, Hisami; KAMINUMA, Eli; SAKAMOTO, Mitsuo; OHKUMA, Moriya; NAKAMURA, Yasukazu; ARITA, Masanori; TOHNO, Masanori

    2017-01-01

    Whole-genome sequencing was performed for Lactobacillus parakefiri JCM 8573T to confirm its hitherto controversial taxonomic position. Here, we report its first reliable reference genome. Genome-wide metrics, such as average nucleotide identity and digital DNA-DNA hybridization, and phylogenomic analysis based on multiple genes supported its taxonomic status as a distinct species in the genus Lactobacillus. The availability of a reliable genome sequence will aid future investigations on the industrial applications of L. parakefiri in functional foods such as kefir grains. PMID:28748134

  7. [Application and prospect of digital technology in the field of orthodontics].

    Science.gov (United States)

    Zhou, Y H

    2016-06-01

    The three-dimensional(3D)digital technology has brought a revolutionary change in diagnostic planning and treatment strategy of orthodontics. Acquisition of 3D image data of the hard and soft tissues of the patients, diagnostic analysis and treatment prediction, and ultimately the individualized orthodontic appliance, will become the development trend and workflow of the 3D orthodontics. With the development of 3D digital technology, the traditional plaster model has been gradually replacing by 3D digital models. Meanwhile, 3D facial soft tissue scan and cone-beam CT scan have been gradually applied to clinical orthodontics, making it possible to get 3D virtual anatomical structure for patients. With the help of digital technology, the diagnostic process is much easier for orthodontist. However how to command the whole digital workflow and put it into practice in the daily work is still a long way to go. The purpose of this article is to enlighten the orthodontists interested in digital technology and discuss the future of digital orthodontics in China.

  8. Microprocessor system to recover data from a self-scanning photodiode array

    International Nuclear Information System (INIS)

    Koppel, L.N.; Gadd, T.J.

    1975-01-01

    A microprocessor system developed at Lawrence Livermore Laboratory has expedited the recovery of data describing the low energy x-ray spectra radiated by laser-fusion targets. An Intel microprocessor controls the digitization and scanning of the data stream of an x-ray-sensitive self-scanning photodiode array incorporated in a crystal diffraction spectrometer

  9. Method for dose-reduced 3D catheter tracking on a scanning-beam digital x-ray system using dynamic electronic collimation

    Science.gov (United States)

    Dunkerley, David A. P.; Funk, Tobias; Speidel, Michael A.

    2016-03-01

    Scanning-beam digital x-ray (SBDX) is an inverse geometry x-ray fluoroscopy system capable of tomosynthesis-based 3D catheter tracking. This work proposes a method of dose-reduced 3D tracking using dynamic electronic collimation (DEC) of the SBDX scanning x-ray tube. Positions in the 2D focal spot array are selectively activated to create a regionof- interest (ROI) x-ray field around the tracked catheter. The ROI position is updated for each frame based on a motion vector calculated from the two most recent 3D tracking results. The technique was evaluated with SBDX data acquired as a catheter tip inside a chest phantom was pulled along a 3D trajectory. DEC scans were retrospectively generated from the detector images stored for each focal spot position. DEC imaging of a catheter tip in a volume measuring 11.4 cm across at isocenter required 340 active focal spots per frame, versus 4473 spots in full-FOV mode. The dose-area-product (DAP) and peak skin dose (PSD) for DEC versus full field-of-view (FOV) scanning were calculated using an SBDX Monte Carlo simulation code. DAP was reduced to 7.4% to 8.4% of the full-FOV value, consistent with the relative number of active focal spots (7.6%). For image sequences with a moving catheter, PSD was 33.6% to 34.8% of the full-FOV value. The root-mean-squared-deviation between DEC-based 3D tracking coordinates and full-FOV 3D tracking coordinates was less than 0.1 mm. The 3D distance between the tracked tip and the sheath centerline averaged 0.75 mm. Dynamic electronic collimation can reduce dose with minimal change in tracking performance.

  10. A study on Computer-controlled Ultrasonic Scanning Device

    International Nuclear Information System (INIS)

    Huh, H.; Park, C. S.; Hong, S. S.; Park, J. H.

    1989-01-01

    Since the nuclear power plants in Korea have been operated in 1979, the nondestructive testing (NDT) of pressure vessels and/or piping welds plays an important role for maintaining the safety and integrity of the plants. Ultrasonic method is superior to the other NDT method in the viewpoint of the detectability of small flaw and accuracy to determine the locations, sizes, orientations, and shapes. As the service time of the nuclear power plants is increased, the radiation level from the components is getting higher. In order to get more quantitative and reliable results and secure the inspector from the exposure to high radiation level, automation of the ultrasonic equipment has been one of the important research and development(R and D) subject. In this research, it was attempted to visualize the shape of flaws presented inside the specimen using a Modified C-Scan technique. In order to develop Modified C-Scan technique, an automatic ultrasonic scanner and a module to control the scanner were designed and fabricated. IBM-PC/XT was interfaced to the module to control the scanner. Analog signals from the SONIC MARK II were digitized by Analog-Digital Converter(ADC 0800) for Modified C-Scan display. A computer program has been developed and has capability of automatic data acquisition and processing from the digital data, which consist of maximum amplitudes in each gate range and locations. The data from Modified C-Scan results was compared with shape from artificial defects using the developed system. Focal length of focused transducer was measured. The automatic ultrasonic equipment developed through this study is essential for more accurate, reliable, and repeatable ultrasonic experiments. If the scanner are modified to meet to appropriate purposes, it can be applied to automation of ultrasonic examination of nuclear power plants and helpful to the research on ultrasonic characterization of the materials

  11. Digital radiography of the chest

    International Nuclear Information System (INIS)

    Sakurai, Kenji; Hachiya, Junichi; Korenaga, Tateo; Nitatori, Toshiaki; Miyasaka, Yasuo; Furuya, Yoshiro

    1984-01-01

    Initial clinical experience in digital chest radiography utilizing photostimulable phosphor and scanning laser stimulated luminescence was reported. Image quality of conventional film/screen radiography and digital radiography was compared in 30 normal cases. Reflecting wide dynamic range of the system, improved image quality was confirmed in all 30 cases, particularly in visibility of various mediastinal structures and pulmonary vessels. High sensor sensitivity of the system enabled digital radiography to reduce radiation dose requirement significantly. Diagnostically acceptable chest images were obtained with approximately 1/5 of routine dose for conventional radiography without significant image quality degradation. Some artifact created by digital processing were mostly overcome by a routine use of simultaneous display of two different types of image processing and therefore was not an actual drawback from diagnostic standpoint. Further technical advancement of the system to be seen for digital storage, retrieval and tranceference of images. (author)

  12. The new scanning nuclear microprobe in Uppsala

    International Nuclear Information System (INIS)

    Sunde, T.; Nystroem, J.; Lindh, U.

    1991-01-01

    During 1989/90 a scanning microprobe, developed for 2-4 MeV protons and submicron resolution, is being installed at the EN-tandem accelerator at the The Svedberg Laboratory, Uppsala University, Sweden. The probe-forming units (object diaphragm, aperture diaphragm and triplet of spark-eroded quadrupoles), the scanning unit of current-controlled ferrite cores and a current digitizer are of Oxford design. The other parts are commercial products or are constructed by ourselves. The latter includes the equipment for optical alignment by interference, a feedback-controlled magnetic beam steerer and stabiliser, a fast beam deflector, specially designed mechanical vibration reducers and dedicated AT expansion cards for scanning control and data acquisition. (orig.)

  13. Digital image analysis of NDT radiographs

    International Nuclear Information System (INIS)

    Graeme, W.A. Jr.; Eizember, A.C.; Douglass, J.

    1989-01-01

    Prior to the introduction of Charge Coupled Device (CCD) detectors the majority of image analysis performed on NDT radiographic images was done visually in the analog domain. While some film digitization was being performed, the process was often unable to capture all the usable information on the radiograph or was too time consuming. CCD technology now provides a method to digitize radiographic film images without losing the useful information captured in the original radiograph in a timely process. Incorporating that technology into a complete digital radiographic workstation allows analog radiographic information to be processed, providing additional information to the radiographer. Once in the digital domain, that data can be stored, and fused with radioscopic and other forms of digital data. The result is more productive analysis and management of radiographic inspection data. The principal function of the NDT Scan IV digital radiography system is the digitization, enhancement and storage of radiographic images

  14. GI-POP: a combinational annotation and genomic island prediction pipeline for ongoing microbial genome projects.

    Science.gov (United States)

    Lee, Chi-Ching; Chen, Yi-Ping Phoebe; Yao, Tzu-Jung; Ma, Cheng-Yu; Lo, Wei-Cheng; Lyu, Ping-Chiang; Tang, Chuan Yi

    2013-04-10

    Sequencing of microbial genomes is important because of microbial-carrying antibiotic and pathogenetic activities. However, even with the help of new assembling software, finishing a whole genome is a time-consuming task. In most bacteria, pathogenetic or antibiotic genes are carried in genomic islands. Therefore, a quick genomic island (GI) prediction method is useful for ongoing sequencing genomes. In this work, we built a Web server called GI-POP (http://gipop.life.nthu.edu.tw) which integrates a sequence assembling tool, a functional annotation pipeline, and a high-performance GI predicting module, in a support vector machine (SVM)-based method called genomic island genomic profile scanning (GI-GPS). The draft genomes of the ongoing genome projects in contigs or scaffolds can be submitted to our Web server, and it provides the functional annotation and highly probable GI-predicting results. GI-POP is a comprehensive annotation Web server designed for ongoing genome project analysis. Researchers can perform annotation and obtain pre-analytic information include possible GIs, coding/non-coding sequences and functional analysis from their draft genomes. This pre-analytic system can provide useful information for finishing a genome sequencing project. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. 3D laser scanning and modelling of the Dhow heritage for the Qatar National Museum

    Science.gov (United States)

    Wetherelt, A.; Cooper, J. P.; Zazzaro, C.

    2014-08-01

    Curating boats can be difficult. They are complex structures, often demanding to conserve whether in or out of the water; they are usually large, difficult to move on land, and demanding of gallery space. Communicating life on board to a visiting public in the terra firma context of a museum can be difficult. Boats in their native environment are inherently dynamic artifacts. In a museum they can be static and divorced from the maritime context that might inspire engagement. New technologies offer new approaches to these problems. 3D laser scanning and digital modeling offers museums a multifaceted means of recording, monitoring, studying and communicating watercraft in their care. In this paper we describe the application of 3D laser scanning and subsequent digital modeling. Laser scans were further developed using computer-generated imagery (CGI) modeling techniques to produce photorealistic 3D digital models for development into interactive, media-based museum displays. The scans were also used to generate 2D naval lines and orthographic drawings as a lasting curatorial record of the dhows held by the National Museum of Qatar.

  16. Utility of Digital Stereo Images for Optic Disc Evaluation

    Science.gov (United States)

    Ying, Gui-shuang; Pearson, Denise J.; Bansal, Mayank; Puri, Manika; Miller, Eydie; Alexander, Judith; Piltz-Seymour, Jody; Nyberg, William; Maguire, Maureen G.; Eledath, Jayan; Sawhney, Harpreet

    2010-01-01

    Purpose. To assess the suitability of digital stereo images for optic disc evaluations in glaucoma. Methods. Stereo color optic disc images in both digital and 35-mm slide film formats were acquired contemporaneously from 29 subjects with various cup-to-disc ratios (range, 0.26–0.76; median, 0.475). Using a grading scale designed to assess image quality, the ease of visualizing optic disc features important for glaucoma diagnosis, and the comparative diameters of the optic disc cup, experienced observers separately compared the primary digital stereo images to each subject's 35-mm slides, to scanned images of the same 35-mm slides, and to grayscale conversions of the digital images. Statistical analysis accounted for multiple gradings and comparisons and also assessed image formats under monoscopic viewing. Results. Overall, the quality of primary digital color images was judged superior to that of 35-mm slides (P digital color images were mostly equivalent to the scanned digitized images of the same slides. Color seemingly added little to grayscale optic disc images, except that peripapillary atrophy was best seen in color (P digital over film images was maintained under monoscopic viewing conditions. Conclusions. Digital stereo optic disc images are useful for evaluating the optic disc in glaucoma and allow the application of advanced image processing applications. Grayscale images, by providing luminance distinct from color, may be informative for assessing certain features. PMID:20505199

  17. Identifying signatures of natural selection in Tibetan and Andean populations using dense genome scan data.

    Directory of Open Access Journals (Sweden)

    Abigail Bigham

    2010-09-01

    Full Text Available High-altitude hypoxia (reduced inspired oxygen tension due to decreased barometric pressure exerts severe physiological stress on the human body. Two high-altitude regions where humans have lived for millennia are the Andean Altiplano and the Tibetan Plateau. Populations living in these regions exhibit unique circulatory, respiratory, and hematological adaptations to life at high altitude. Although these responses have been well characterized physiologically, their underlying genetic basis remains unknown. We performed a genome scan to identify genes showing evidence of adaptation to hypoxia. We looked across each chromosome to identify genomic regions with previously unknown function with respect to altitude phenotypes. In addition, groups of genes functioning in oxygen metabolism and sensing were examined to test the hypothesis that particular pathways have been involved in genetic adaptation to altitude. Applying four population genetic statistics commonly used for detecting signatures of natural selection, we identified selection-nominated candidate genes and gene regions in these two populations (Andeans and Tibetans separately. The Tibetan and Andean patterns of genetic adaptation are largely distinct from one another, with both populations showing evidence of positive natural selection in different genes or gene regions. Interestingly, one gene previously known to be important in cellular oxygen sensing, EGLN1 (also known as PHD2, shows evidence of positive selection in both Tibetans and Andeans. However, the pattern of variation for this gene differs between the two populations. Our results indicate that several key HIF-regulatory and targeted genes are responsible for adaptation to high altitude in Andeans and Tibetans, and several different chromosomal regions are implicated in the putative response to selection. These data suggest a genetic role in high-altitude adaption and provide a basis for future genotype/phenotype association

  18. Comparison of the automated evaluation of phantom mama in digital and digitalized images

    International Nuclear Information System (INIS)

    Santana, Priscila do Carmo

    2011-01-01

    Mammography is an essential tool for diagnosis and early detection of breast cancer if it is provided as a very good quality service. The process of evaluating the quality of radiographic images in general, and mammography in particular, can be much more accurate, practical and fast with the help of computer analysis tools. This work compare the automated methodology for the evaluation of scanned digital images the phantom mama. By applied the DIP method techniques was possible determine geometrical and radiometric images evaluated. The evaluated parameters include circular details of low contrast, contrast ratio, spatial resolution, tumor masses, optical density and background in Phantom Mama scanned and digitized images. The both results of images were evaluated. Through this comparison was possible to demonstrate that this automated methodology is presented as a promising alternative for the reduction or elimination of subjectivity in both types of images, but the Phantom Mama present insufficient parameters for spatial resolution evaluation. (author)

  19. Digital radiography using scintillating screens

    International Nuclear Information System (INIS)

    Salvini, E.

    1988-01-01

    This paper briefly describes the technical features of a digital radiographic system based on the principle of scanning laser stimulated luminescence. Such aspects as the physics of the stimulable phosphor detector are dealt with, and image acquisition, processing, and hard-copy output. Automatic analysis of pixel histograms is described, in a qualitative way, together with contrast modifications and spatial filtering. Physical image characteristics are reported. The overall performance of digital radiography is examined, together with the current requirements and its eventual developments

  20. Analysis tools for the interplay between genome layout and regulation.

    Science.gov (United States)

    Bouyioukos, Costas; Elati, Mohamed; Képès, François

    2016-06-06

    Genome layout and gene regulation appear to be interdependent. Understanding this interdependence is key to exploring the dynamic nature of chromosome conformation and to engineering functional genomes. Evidence for non-random genome layout, defined as the relative positioning of either co-functional or co-regulated genes, stems from two main approaches. Firstly, the analysis of contiguous genome segments across species, has highlighted the conservation of gene arrangement (synteny) along chromosomal regions. Secondly, the study of long-range interactions along a chromosome has emphasised regularities in the positioning of microbial genes that are co-regulated, co-expressed or evolutionarily correlated. While one-dimensional pattern analysis is a mature field, it is often powerless on biological datasets which tend to be incomplete, and partly incorrect. Moreover, there is a lack of comprehensive, user-friendly tools to systematically analyse, visualise, integrate and exploit regularities along genomes. Here we present the Genome REgulatory and Architecture Tools SCAN (GREAT:SCAN) software for the systematic study of the interplay between genome layout and gene expression regulation. SCAN is a collection of related and interconnected applications currently able to perform systematic analyses of genome regularities as well as to improve transcription factor binding sites (TFBS) and gene regulatory network predictions based on gene positional information. We demonstrate the capabilities of these tools by studying on one hand the regular patterns of genome layout in the major regulons of the bacterium Escherichia coli. On the other hand, we demonstrate the capabilities to improve TFBS prediction in microbes. Finally, we highlight, by visualisation of multivariate techniques, the interplay between position and sequence information for effective transcription regulation.

  1. Evaluating droplet digital PCR for the quantification of human genomic DNA: converting copies per nanoliter to nanograms nuclear DNA per microliter.

    Science.gov (United States)

    Duewer, David L; Kline, Margaret C; Romsos, Erica L; Toman, Blaza

    2018-05-01

    The highly multiplexed polymerase chain reaction (PCR) assays used for forensic human identification perform best when used with an accurately determined quantity of input DNA. To help ensure the reliable performance of these assays, we are developing a certified reference material (CRM) for calibrating human genomic DNA working standards. To enable sharing information over time and place, CRMs must provide accurate and stable values that are metrologically traceable to a common reference. We have shown that droplet digital PCR (ddPCR) limiting dilution end-point measurements of the concentration of DNA copies per volume of sample can be traceably linked to the International System of Units (SI). Unlike values assigned using conventional relationships between ultraviolet absorbance and DNA mass concentration, entity-based ddPCR measurements are expected to be stable over time. However, the forensic community expects DNA quantity to be stated in terms of mass concentration rather than entity concentration. The transformation can be accomplished given SI-traceable values and uncertainties for the number of nucleotide bases per human haploid genome equivalent (HHGE) and the average molar mass of a nucleotide monomer in the DNA polymer. This report presents the considerations required to establish the metrological traceability of ddPCR-based mass concentration estimates of human nuclear DNA. Graphical abstract The roots of metrological traceability for human nuclear DNA mass concentration results. Values for the factors in blue must be established experimentally. Values for the factors in red have been established from authoritative source materials. HHGE stands for "haploid human genome equivalent"; there are two HHGE per diploid human genome.

  2. Accuracy of full-arch scans using intraoral and extraoral scanners: an in vitro study using a new method of evaluation.

    Science.gov (United States)

    Muallah, Jonas; Wesemann, Christian; Nowak, Roxana; Robben, Jan; Mah, James; Pospiech, Peter; Bumann, Axel

    The aim of this study was to compare the accuracy of six intraoral scanners as regards clinically relevant distances using a new method of evaluation. An additional objective was to compare intraoral scanners with the indirect digitization of model scanners. A resin master model was created by 3D printing and drilled in five places to reflect the following distances: intermolar width (IMW), intercanine width (ICW), and arch length (AL). To determine a gold standard, the distances were measured with a coordinate measuring instrument (Zeiss O-Inspect 422). The master model was scanned 37 times with the following intraoral scanners: Apollo DI (Sirona), CS 3500 (Carestream Dental), iTero (Cadent), PlanScan (Planmeca), Trios (3Shape), and True Definition (3M Espe), and indirectly digitized with the OrthoX Scan (Dentaurum). The digital models were then measured, and deviations from the gold standard calculated. Significant differences were found between the devices. Among the intraoral scanners, Trios and iTero showed the most accurate results, although CS 3500, True Definition, and Apollo DI achieved comparable results. PlanScan demonstrated the highest deviations from the gold standard, and presented a high standard deviation (SD). Direct digitization revealed comparable (and, in fact, slightly higher) accuracy than indirect digitization. Both indirect digitization and most of the intraoral scanners were therefore demonstrated to be suitable for use in the orthodontic office, with the exception of PlanScan, which did not meet the demands of individual orthodontic treatment.

  3. Qualification process of CR system and quantification of digital image quality

    Science.gov (United States)

    Garnier, P.; Hun, L.; Klein, J.; Lemerle, C.

    2013-01-01

    CEA Valduc uses several X-Ray generators to carry out many inspections: void search, welding expertise, gap measurements, etc. Most of these inspections are carried out on silver based plates. For several years, the CEA/Valduc has decided to qualify new devices such as digital plates or CCD/flat panel plates. On one hand, the choice of this technological orientation is to forecast the assumed and eventual disappearance of silver based plates; on the other hand, it is also to keep our skills mastering up-to-date. The main improvement brought by numerical plates is the continuous progress of the measurement accuracy, especially with image data processing. It is now common to measure defects thickness or depth position within a part. In such applications, data image processing is used to obtain complementary information compared to scanned silver based plates. This scanning procedure is harmful for measurements which imply a data corruption of the resolution, the adding of numerical noise and is time expensive. Digital plates enable to suppress the scanning procedure and to increase resolution. It is nonetheless difficult to define, for digital images, single criteria for the image quality. A procedure has to be defined in order to estimate quality of the digital data itself; the impact of the scanning device and the configuration parameters are also to be taken into account. This presentation deals with the qualification process developed by CEA/Valduc for digital plates (DUR-NDT) based on the study of quantitative criteria chosen to define a direct numerical image quality that could be compared with scanned silver based pictures and the classical optical density. The versatility of the X-Ray parameters is also discussed (X-ray tension, intensity, time exposure). The aim is to be able to transfer the year long experience of CEA/Valduc with silver-based plates inspection to these new digital plates supports. This is an industrial stake.

  4. Personal genomics services: whose genomes?

    Science.gov (United States)

    Gurwitz, David; Bregman-Eschet, Yael

    2009-07-01

    New companies offering personal whole-genome information services over the internet are dynamic and highly visible players in the personal genomics field. For fees currently ranging from US$399 to US$2500 and a vial of saliva, individuals can now purchase online access to their individual genetic information regarding susceptibility to a range of chronic diseases and phenotypic traits based on a genome-wide SNP scan. Most of the companies offering such services are based in the United States, but their clients may come from nearly anywhere in the world. Although the scientific validity, clinical utility and potential future implications of such services are being hotly debated, several ethical and regulatory questions related to direct-to-consumer (DTC) marketing strategies of genetic tests have not yet received sufficient attention. For example, how can we minimize the risk of unauthorized third parties from submitting other people's DNA for testing? Another pressing question concerns the ownership of (genotypic and phenotypic) information, as well as the unclear legal status of customers regarding their own personal information. Current legislation in the US and Europe falls short of providing clear answers to these questions. Until the regulation of personal genomics services catches up with the technology, we call upon commercial providers to self-regulate and coordinate their activities to minimize potential risks to individual privacy. We also point out some specific steps, along the trustee model, that providers of DTC personal genomics services as well as regulators and policy makers could consider for addressing some of the concerns raised below.

  5. Enterprise Implementation of Digital Pathology: Feasibility, Challenges, and Opportunities.

    Science.gov (United States)

    Hartman, D J; Pantanowitz, L; McHugh, J S; Piccoli, A L; OLeary, M J; Lauro, G R

    2017-10-01

    Digital pathology is becoming technically possible to implement for routine pathology work. At our institution, we have been using digital pathology for second opinion intraoperative consultations for over 10 years. Herein, we describe our experience in converting to a digital pathology platform for primary pathology diagnosis. We implemented an incremental rollout for digital pathology on subspecialty benches, beginning with cases that contained small amounts of tissue (biopsy specimens). We successfully scanned over 40,000 slides through our digital pathology system. Several lessons (both challenges and opportunities) were learned through this implementation. A successful conversion to digital pathology requires pre-imaging adjustments, integrated software and post-imaging evaluations.

  6. Knowledge Organisation Systems in North American Digital Library Collections

    Science.gov (United States)

    Shiri, Ali; Chase-Kruszewski, Sarah

    2009-01-01

    Purpose: The purpose of this paper is to report an investigation into the types of knowledge organisation systems (KOSs) utilised in North American digital library collections. Design/methodology/approach: The paper identifies, analyses and deep scans online North American hosted digital libraries. It reviews the literature related to the…

  7. Image analysis and machine learning in digital pathology: Challenges and opportunities.

    Science.gov (United States)

    Madabhushi, Anant; Lee, George

    2016-10-01

    With the rise in whole slide scanner technology, large numbers of tissue slides are being scanned and represented and archived digitally. While digital pathology has substantial implications for telepathology, second opinions, and education there are also huge research opportunities in image computing with this new source of "big data". It is well known that there is fundamental prognostic data embedded in pathology images. The ability to mine "sub-visual" image features from digital pathology slide images, features that may not be visually discernible by a pathologist, offers the opportunity for better quantitative modeling of disease appearance and hence possibly improved prediction of disease aggressiveness and patient outcome. However the compelling opportunities in precision medicine offered by big digital pathology data come with their own set of computational challenges. Image analysis and computer assisted detection and diagnosis tools previously developed in the context of radiographic images are woefully inadequate to deal with the data density in high resolution digitized whole slide images. Additionally there has been recent substantial interest in combining and fusing radiologic imaging and proteomics and genomics based measurements with features extracted from digital pathology images for better prognostic prediction of disease aggressiveness and patient outcome. Again there is a paucity of powerful tools for combining disease specific features that manifest across multiple different length scales. The purpose of this review is to discuss developments in computational image analysis tools for predictive modeling of digital pathology images from a detection, segmentation, feature extraction, and tissue classification perspective. We discuss the emergence of new handcrafted feature approaches for improved predictive modeling of tissue appearance and also review the emergence of deep learning schemes for both object detection and tissue classification

  8. Fast-scan, beam-profile monitor

    International Nuclear Information System (INIS)

    Waugh, A.F.

    1977-01-01

    A minimodular, data-acquisition system can be used to rapidly interrogate a 45-point matrix of beam-current sampling targets over the 3- x 12-in. rectangular, output beam cross section of a 50-A, neutral-beam ion source. This system, operating at a throughput rate of 12 μs per channel, can make several complete scans during the 10- to 25-ms-duration beam pulse. Data obtained are available in both analog and digital form. The analog signal is used to create an immediately interpretable CRT display of the beam-current density profile that shows how well the source is aimed. The digital data are held in buffer memory until transfer to a minicomputer for software processing and plotting

  9. Intraoral 3D Scanning or Dental Impressions for the Assessment of Dental Arch Relationships in Cleft Care: Which is Superior?

    Science.gov (United States)

    Chalmers, E V; McIntyre, G T; Wang, W; Gillgrass, T; Martin, C B; Mossey, P A

    2016-09-01

    This study was undertaken to evaluate intraoral 3D scans for assessing dental arch relationships and obtain patient/parent perceptions of impressions and intraoral 3D scanning. Forty-three subjects with nonsyndromic unilateral cleft lip and palate (UCLP) had impressions taken for plaster models. These and the teeth were scanned using the R700 Orthodontic Study Model Scanner and Trios® Digital Impressions Scanner (3Shape A/S, Copenhagen, Denmark) to create indirect and direct digital models. All model formats were scored by three observers on two occasions using the GOSLON and modified Huddart Bodenham (MHB) indices. Participants and parents scored their perceptions of impressions and scanning from 1 (very good) to 5 (very bad). Intra- and interexaminer reliability were tested using GOSLON and MHB data (Cronbach's Alpha >0.9). Bland and Altman plots were created for MHB data, with each model medium (one-sample t tests, P 0.9) were good for all formats with the direct digital models having the lowest interexaminer differences. Participants had higher ratings for scanning comfort (84.8%) than impressions (44.2%) (P impressions (51.2%) (P > .05). None disliked scanning, but 16.3% disliked impressions. Data for parents and children positively correlated (P 3D scans was superior to indirect digital and to plaster models; Subjects with UCLP preferred intra-oral 3D scanning to dental impressions, mirrored by parents/carers; This study supports the replacement of conventional impressions with intra-oral 3D scans in longitudinal evaluations of the outcomes of cleft care.

  10. Development of digital reconstructed radiography software at new treatment facility for carbon-ion beam scanning of National Institute of Radiological Sciences.

    Science.gov (United States)

    Mori, Shinichiro; Inaniwa, Taku; Kumagai, Motoki; Kuwae, Tsunekazu; Matsuzaki, Yuka; Furukawa, Takuji; Shirai, Toshiyuki; Noda, Koji

    2012-06-01

    To increase the accuracy of carbon ion beam scanning therapy, we have developed a graphical user interface-based digitally-reconstructed radiograph (DRR) software system for use in routine clinical practice at our center. The DRR software is used in particular scenarios in the new treatment facility to achieve the same level of geometrical accuracy at the treatment as at the imaging session. DRR calculation is implemented simply as the summation of CT image voxel values along the X-ray projection ray. Since we implemented graphics processing unit-based computation, the DRR images are calculated with a speed sufficient for the particular clinical practice requirements. Since high spatial resolution flat panel detector (FPD) images should be registered to the reference DRR images in patient setup process in any scenarios, the DRR images also needs higher spatial resolution close to that of FPD images. To overcome the limitation of the CT spatial resolution imposed by the CT voxel size, we applied image processing to improve the calculated DRR spatial resolution. The DRR software introduced here enabled patient positioning with sufficient accuracy for the implementation of carbon-ion beam scanning therapy at our center.

  11. A reference gene set for sex pheromone biosynthesis and degradation genes from the diamondback moth, Plutella xylostella, based on genome and transcriptome digital gene expression analyses

    OpenAIRE

    He, Peng; Zhang, Yun-Fei; Hong, Duan-Yang; Wang, Jun; Wang, Xing-Liang; Zuo, Ling-Hua; Tang, Xian-Fu; Xu, Wei-Ming; He, Ming

    2017-01-01

    Background Female moths synthesize species-specific sex pheromone components and release them to attract male moths, which depend on precise sex pheromone chemosensory system to locate females. Two types of genes involved in the sex pheromone biosynthesis and degradation pathways play essential roles in this important moth behavior. To understand the function of genes in the sex pheromone pathway, this study investigated the genome-wide and digital gene expression of sex pheromone biosynthesi...

  12. Dexter: Data Extractor for scanned graphs

    Science.gov (United States)

    Demleitner, Markus

    2011-12-01

    The NASA Astrophysics Data System (ADS) now holds 1.3 million scanned pages, containing numerous plots and figures for which the original data sets are lost or inaccessible. The availability of scans of the figures can significantly ease the regeneration of the data sets. For this purpose, the ADS has developed Dexter, a Java applet that supports the user in this process. Dexter's basic functionality is to let the user manually digitize a plot by marking points and defining the coordinate transformation from the logical to the physical coordinate system. Advanced features include automatic identification of axes, tracing lines and finding points matching a template.

  13. Comparative study of digital laser film and analog paper image recordings

    International Nuclear Information System (INIS)

    Lee, K.R.; Cox, G.G.; Templeton, A.W.; Preston, D.F.; Anderson, W.H.; Hensley, K.S.; Dwyer, S.J.

    1987-01-01

    The increase in the use of various imaging modalities demands higher quality and more efficacious analog image recordings. Laser electronic recordings with digital array prints of 4,000 x 5,000 x 12 bits obtained using laser-sensitive film or paper are being evaluated. Dry silver paper recordings are being improved and evaluated. High-resolution paper dot printers are being studied to determine their gray-scale capabilities. The authors evaluated the image quality, costs, clinical utilization, and acceptability of CT scans, MR images, digital subtraction angiograms, digital radiographs, and radionuclide scans recorded by seven different printers (three laser, three silver paper, and one dot) and compared the same features in conventional film recording. This exhibit outlines the technical developments and instrumentation of digital laser film and analog paper recorders and presents the results of the study

  14. Digitization of dental alginate impression: Three-dimensional evaluation of point cloud.

    Science.gov (United States)

    Kim, So-Ri; Lee, Wan-Sun; Kim, Woong-Chul; Kim, Hea-Young; Kim, Ji-Hwan

    2015-01-01

    The purpose of this study was to evaluate the digitization of alginate impressions by analyzing differences between the scan data of two types of impressions (alginate and rubber) taken from the master die and the scan data for the master die. The master die and impressions were digitized using a dental laser scanner (7 series, Dental Wings, Montreal, Canada). The crown portion of the abutment teeth in the digital data of 20 impressions was divided into three regions: cervical surface, middle surface, and occlusal surface. An independent t-test showed a significant difference (palginate and rubber). One-way ANOVA and Tukey's honest significant difference test revealed a significant difference (palginate impressions in the future.

  15. Gamma scanning equipment for nuclear safeguards

    International Nuclear Information System (INIS)

    De Grandi, G.; Stanchi, L.

    1975-01-01

    Many reasons justify the use of gamma techniques in the field of nuclear safeguards. The paper describes electronic equipment for gamma-scanning of non-irradiated fuel elements. The control of the operation is completely digital and driven by a minicomputer and gives more accurate results in respect of an analog chain which has been successfully used in fuel element manufacturing plants

  16. Ginseng Genome Database: an open-access platform for genomics of Panax ginseng.

    Science.gov (United States)

    Jayakodi, Murukarthick; Choi, Beom-Soon; Lee, Sang-Choon; Kim, Nam-Hoon; Park, Jee Young; Jang, Woojong; Lakshmanan, Meiyappan; Mohan, Shobhana V G; Lee, Dong-Yup; Yang, Tae-Jin

    2018-04-12

    The ginseng (Panax ginseng C.A. Meyer) is a perennial herbaceous plant that has been used in traditional oriental medicine for thousands of years. Ginsenosides, which have significant pharmacological effects on human health, are the foremost bioactive constituents in this plant. Having realized the importance of this plant to humans, an integrated omics resource becomes indispensable to facilitate genomic research, molecular breeding and pharmacological study of this herb. The first draft genome sequences of P. ginseng cultivar "Chunpoong" were reported recently. Here, using the draft genome, transcriptome, and functional annotation datasets of P. ginseng, we have constructed the Ginseng Genome Database http://ginsengdb.snu.ac.kr /, the first open-access platform to provide comprehensive genomic resources of P. ginseng. The current version of this database provides the most up-to-date draft genome sequence (of approximately 3000 Mbp of scaffold sequences) along with the structural and functional annotations for 59,352 genes and digital expression of genes based on transcriptome data from different tissues, growth stages and treatments. In addition, tools for visualization and the genomic data from various analyses are provided. All data in the database were manually curated and integrated within a user-friendly query page. This database provides valuable resources for a range of research fields related to P. ginseng and other species belonging to the Apiales order as well as for plant research communities in general. Ginseng genome database can be accessed at http://ginsengdb.snu.ac.kr /.

  17. Comparison between a digital scanning system and a conventional screen film system in the full spine radiological procedure in pediatrics

    International Nuclear Information System (INIS)

    Espana, M. L.; Gomez, G.; Romero, A.; Minambres, A.; Albi, G.; Floriano, A.; Rodirguez, A.; Lopez Franco, P.

    2004-01-01

    To compare from both dosimetry and image quality standpoints, a digital scanning system with a conventional screen film system, in the full spine radiological procedure. The standard patient is considered to be 12 years old, and a sample of forty patients referred for full spine radiological procedure has been studied. Gonad shielding has been used in all the patients, and its efficiency has been evaluated. Dosimetric study includes Kerma-area product, and thorax and gonad entrance surface dose. Kerma area product has been measured using a transmission camera, and for entrance surface dose estimation both thermoluminescent dosemeter LiF: Mg, Cu, P and LiF: Mg, Ti have been utilized. Three radiologists have evaluated the image quality according to the degree of fulfilment of the image quality criteria. (Author) 22 refs

  18. Digitalization and networking of analog simulators and portal images

    Energy Technology Data Exchange (ETDEWEB)

    Pesznyak, C.; Zarand, P.; Mayer, A. [Uzsoki Hospital, Budapest (Hungary). Inst. of Oncoradiology

    2007-03-15

    Background: Many departments have analog simulators and irradiation facilities (especially cobalt units) without electronic portal imaging. Import of the images into the R and V (Record and Verify) system is required. Material and Methods: Simulator images are grabbed while portal films scanned by using a laser scanner and both converted into DICOM RT (Digital Imaging and Communications in Medicine Radiotherapy) images. Results: Image intensifier output of a simulator and portal films are converted to DICOM RT images and used in clinical practice. The simulator software was developed in cooperation at the authors' hospital. Conclusion: The digitalization of analog simulators is a valuable updating in clinical use replacing screen-film technique. Film scanning and digitalization permit the electronic archiving of films. Conversion into DICOM RT images is a precondition of importing to the R and V system. (orig.)

  19. Measuring digit lengths with 3D digital stereophotogrammetry: A comparison across methods.

    Science.gov (United States)

    Gremba, Allison; Weinberg, Seth M

    2018-05-09

    We compared digital 3D stereophotogrammetry to more traditional measurement methods (direct anthropometry and 2D scanning) to capture digit lengths and ratios. The length of the second and fourth digits was measured by each method and the second-to-fourth ratio was calculated. For each digit measurement, intraobserver agreement was calculated for each of the three collection methods. Further, measurements from the three methods were compared directly to one another. Agreement statistics included the intraclass correlation coefficient (ICC) and technical error of measurement (TEM). Intraobserver agreement statistics for the digit length measurements were high for all three methods; ICC values exceeded 0.97 and TEM values were below 1 mm. For digit ratio, intraobserver agreement was also acceptable for all methods, with direct anthropometry exhibiting lower agreement (ICC = 0.87) compared to indirect methods. For the comparison across methods, the overall agreement was high for digit length measurements (ICC values ranging from 0.93 to 0.98; TEM values below 2 mm). For digit ratios, high agreement was observed between the two indirect methods (ICC = 0.93), whereas indirect methods showed lower agreement when compared to direct anthropometry (ICC < 0.75). Digit measurements and derived ratios from 3D stereophotogrammetry showed high intraobserver agreement (similar to more traditional methods) suggesting that landmarks could be placed reliably on 3D hand surface images. While digit length measurements were found to be comparable across all three methods, ratios derived from direct anthropometry tended to be higher than those calculated indirectly from 2D or 3D images. © 2018 Wiley Periodicals, Inc.

  20. Optimal scanning and image processing with the STEM

    International Nuclear Information System (INIS)

    Crewe, A.V.; Ohtsuki, M.

    1981-01-01

    We have recently published a theory of an optimal scanning system which is particularly suited for the STEM. One concludes from the theory that the diffraction limit of the electron probe should be a fixed fraction of the full-scale deflection in order to avoid scanning artifacts. More recently, we have confirmed the value of this technique by direct experiments. Our program now is to combine the use of optimal scanning with the use of a programmable digital refresh memory for image analysis. Limited experience to date indicates that false color conversion is probably more useful than histogram equalization in black and white and that this system is particularly valuable for rotational averaging and selected area Fourier transforms. (orig.)

  1. Printing line/space patterns on nonplanar substrates using a digital micromirror device-based point-array scanning technique

    Science.gov (United States)

    Kuo, Hung-Fei; Kao, Guan-Hsuan; Zhu, Liang-Xiu; Hung, Kuo-Shu; Lin, Yu-Hsin

    2018-02-01

    This study used a digital micromirror device (DMD) to produce point-array patterns and employed a self-developed optical system to define line-and-space patterns on nonplanar substrates. First, field tracing was employed to analyze the aerial images of the lithographic system, which comprised an optical system and the DMD. Multiobjective particle swarm optimization was then applied to determine the spot overlapping rate used. The objective functions were set to minimize linewidth and maximize image log slope, through which the dose of the exposure agent could be effectively controlled and the quality of the nonplanar lithography could be enhanced. Laser beams with 405-nm wavelength were employed as the light source. Silicon substrates coated with photoresist were placed on a nonplanar translation stage. The DMD was used to produce lithographic patterns, during which the parameters were analyzed and optimized. The optimal delay time-sequence combinations were used to scan images of the patterns. Finally, an exposure linewidth of less than 10 μm was successfully achieved using the nonplanar lithographic process.

  2. Using optically scanned 3D data in the restoration of Michelangelo's David

    Science.gov (United States)

    Scopigno, Roberto; Cignoni, Paolo; Callieri, Marco; Ganovelli, Fabio; Impoco, G.; Pingi, P.; Ponchio, F.

    2003-10-01

    Modern 3D scanning technologies allow to reconstruct 3D digital representations of Cultural Heritage artifacts in a semi-automatic way, characterized by very high accuracy and wealth of details. The availability of an accurate digital representation opens several possibilities of utilization to experts (restorers, archivists, museum curators), or to ordinary people (students, museum visitors). 3D scanned data are commonly used for the production of animations, interactive visualizations, or virtual reality applications. A much more exciting opportunity is to use these data in the restoration of Cultural Heritage artworks. The integration between 3D graphic and restoration represents an open research field where many new supporting tools are required; the David restoration project has given several starting points and guidelines to the definition and development of innovative solutions. Digital 3D models can be used in two different but not subsidiary modes: as an instrument for the execution of specific investigations and as a supporting media for the archival and integration of all the restoration-related information, gathered with the different studies and analysis performed on the artwork. In this paper we present some recent work done in the framework of the Michelangelo's David restoration project. A 3D model of the David was reconstructed by the Digital Michelangelo Project, using laser-based 3D scanning technology. We have developed some tools to make those data accessible and useful in the restoration. Preliminary results are reported here together with some directions for further research.

  3. Population genomics of parallel adaptation in threespine stickleback using sequenced RAD tags.

    Directory of Open Access Journals (Sweden)

    Paul A Hohenlohe

    2010-02-01

    Full Text Available Next-generation sequencing technology provides novel opportunities for gathering genome-scale sequence data in natural populations, laying the empirical foundation for the evolving field of population genomics. Here we conducted a genome scan of nucleotide diversity and differentiation in natural populations of threespine stickleback (Gasterosteus aculeatus. We used Illumina-sequenced RAD tags to identify and type over 45,000 single nucleotide polymorphisms (SNPs in each of 100 individuals from two oceanic and three freshwater populations. Overall estimates of genetic diversity and differentiation among populations confirm the biogeographic hypothesis that large panmictic oceanic populations have repeatedly given rise to phenotypically divergent freshwater populations. Genomic regions exhibiting signatures of both balancing and divergent selection were remarkably consistent across multiple, independently derived populations, indicating that replicate parallel phenotypic evolution in stickleback may be occurring through extensive, parallel genetic evolution at a genome-wide scale. Some of these genomic regions co-localize with previously identified QTL for stickleback phenotypic variation identified using laboratory mapping crosses. In addition, we have identified several novel regions showing parallel differentiation across independent populations. Annotation of these regions revealed numerous genes that are candidates for stickleback phenotypic evolution and will form the basis of future genetic analyses in this and other organisms. This study represents the first high-density SNP-based genome scan of genetic diversity and differentiation for populations of threespine stickleback in the wild. These data illustrate the complementary nature of laboratory crosses and population genomic scans by confirming the adaptive significance of previously identified genomic regions, elucidating the particular evolutionary and demographic history of such

  4. Genome-wide association scan shows genetic variants in the FTO gene are associated with obesity-related traits.

    Directory of Open Access Journals (Sweden)

    Angelo Scuteri

    2007-07-01

    Full Text Available The obesity epidemic is responsible for a substantial economic burden in developed countries and is a major risk factor for type 2 diabetes and cardiovascular disease. The disease is the result not only of several environmental risk factors, but also of genetic predisposition. To take advantage of recent advances in gene-mapping technology, we executed a genome-wide association scan to identify genetic variants associated with obesity-related quantitative traits in the genetically isolated population of Sardinia. Initial analysis suggested that several SNPs in the FTO and PFKP genes were associated with increased BMI, hip circumference, and weight. Within the FTO gene, rs9930506 showed the strongest association with BMI (p = 8.6 x10(-7, hip circumference (p = 3.4 x 10(-8, and weight (p = 9.1 x 10(-7. In Sardinia, homozygotes for the rare "G" allele of this SNP (minor allele frequency = 0.46 were 1.3 BMI units heavier than homozygotes for the common "A" allele. Within the PFKP gene, rs6602024 showed very strong association with BMI (p = 4.9 x 10(-6. Homozygotes for the rare "A" allele of this SNP (minor allele frequency = 0.12 were 1.8 BMI units heavier than homozygotes for the common "G" allele. To replicate our findings, we genotyped these two SNPs in the GenNet study. In European Americans (N = 1,496 and in Hispanic Americans (N = 839, we replicated significant association between rs9930506 in the FTO gene and BMI (p-value for meta-analysis of European American and Hispanic American follow-up samples, p = 0.001, weight (p = 0.001, and hip circumference (p = 0.0005. We did not replicate association between rs6602024 and obesity-related traits in the GenNet sample, although we found that in European Americans, Hispanic Americans, and African Americans, homozygotes for the rare "A" allele were, on average, 1.0-3.0 BMI units heavier than homozygotes for the more common "G" allele. In summary, we have completed a whole genome-association scan for

  5. A Genome Scan for Quantitative Trait Loci Affecting Average Daily ...

    Indian Academy of Sciences (India)

    reviewer

    Sari, P.O. Box -578, Iran .... (2015) identified one SNP with genome wide significance effect within SYNE1 gene on ..... analysis of thirty one production, health, reproduction and body conformation traits in contemporary US Holstein cows. ... Problems involved in breeding for efficiency of food utilization. Proc .... 131, 210-216.

  6. Digital dissection - using contrast-enhanced computed tomography scanning to elucidate hard- and soft-tissue anatomy in the Common Buzzard Buteo buteo.

    Science.gov (United States)

    Lautenschlager, Stephan; Bright, Jen A; Rayfield, Emily J

    2014-04-01

    Gross dissection has a long history as a tool for the study of human or animal soft- and hard-tissue anatomy. However, apart from being a time-consuming and invasive method, dissection is often unsuitable for very small specimens and often cannot capture spatial relationships of the individual soft-tissue structures. The handful of comprehensive studies on avian anatomy using traditional dissection techniques focus nearly exclusively on domestic birds, whereas raptorial birds, and in particular their cranial soft tissues, are essentially absent from the literature. Here, we digitally dissect, identify, and document the soft-tissue anatomy of the Common Buzzard (Buteo buteo) in detail, using the new approach of contrast-enhanced computed tomography using Lugol's iodine. The architecture of different muscle systems (adductor, depressor, ocular, hyoid, neck musculature), neurovascular, and other soft-tissue structures is three-dimensionally visualised and described in unprecedented detail. The three-dimensional model is further presented as an interactive PDF to facilitate the dissemination and accessibility of anatomical data. Due to the digital nature of the data derived from the computed tomography scanning and segmentation processes, these methods hold the potential for further computational analyses beyond descriptive and illustrative proposes. © 2013 The Authors. Journal of Anatomy published by John Wiley & Sons Ltd on behalf of Anatomical Society.

  7. Cancer Slide Digital Archive (CDSA) | Informatics Technology for Cancer Research (ITCR)

    Science.gov (United States)

    The CDSA is a web-based platform to support the sharing, managment and analysis of digital pathology data. The Emory Instance currently hosts over 23,000 images from The Cancer Genome Atlas, and the software is being developed within the ITCR grant to be deployable as a digital pathology platform for other labs and Cancer Institutes.

  8. Signatures of selection in the Iberian honey bee (Apis mellifera iberiensis) revealed by a genome scan analysis of single nucleotide polymorphisms.

    Science.gov (United States)

    Chávez-Galarza, Julio; Henriques, Dora; Johnston, J Spencer; Azevedo, João C; Patton, John C; Muñoz, Irene; De la Rúa, Pilar; Pinto, M Alice

    2013-12-01

    Understanding the genetic mechanisms of adaptive population divergence is one of the most fundamental endeavours in evolutionary biology and is becoming increasingly important as it will allow predictions about how organisms will respond to global environmental crisis. This is particularly important for the honey bee, a species of unquestionable ecological and economical importance that has been exposed to increasing human-mediated selection pressures. Here, we conducted a single nucleotide polymorphism (SNP)-based genome scan in honey bees collected across an environmental gradient in Iberia and used four FST -based outlier tests to identify genomic regions exhibiting signatures of selection. Additionally, we analysed associations between genetic and environmental data for the identification of factors that might be correlated or act as selective pressures. With these approaches, 4.4% (17 of 383) of outlier loci were cross-validated by four FST -based methods, and 8.9% (34 of 383) were cross-validated by at least three methods. Of the 34 outliers, 15 were found to be strongly associated with one or more environmental variables. Further support for selection, provided by functional genomic information, was particularly compelling for SNP outliers mapped to different genes putatively involved in the same function such as vision, xenobiotic detoxification and innate immune response. This study enabled a more rigorous consideration of selection as the underlying cause of diversity patterns in Iberian honey bees, representing an important first step towards the identification of polymorphisms implicated in local adaptation and possibly in response to recent human-mediated environmental changes. © 2013 John Wiley & Sons Ltd.

  9. An automated annotation tool for genomic DNA sequences using

    Indian Academy of Sciences (India)

    Genomic sequence data are often available well before the annotated sequence is published. We present a method for analysis of genomic DNA to identify coding sequences using the GeneScan algorithm and characterize these resultant sequences by BLAST. The routines are used to develop a system for automated ...

  10. Identification of prophages in bacterial genomes by dinucleotide relative abundance difference.

    Directory of Open Access Journals (Sweden)

    K V Srividhya

    Full Text Available BACKGROUND: Prophages are integrated viral forms in bacterial genomes that have been found to contribute to interstrain genetic variability. Many virulence-associated genes are reported to be prophage encoded. Present computational methods to detect prophages are either by identifying possible essential proteins such as integrases or by an extension of this technique, which involves identifying a region containing proteins similar to those occurring in prophages. These methods suffer due to the problem of low sequence similarity at the protein level, which suggests that a nucleotide based approach could be useful. METHODOLOGY: Earlier dinucleotide relative abundance (DRA have been used to identify regions, which deviate from the neighborhood areas, in genomes. We have used the difference in the dinucleotide relative abundance (DRAD between the bacterial and prophage DNA to aid location of DNA stretches that could be of prophage origin in bacterial genomes. Prophage sequences which deviate from bacterial regions in their dinucleotide frequencies are detected by scanning bacterial genome sequences. The method was validated using a subset of genomes with prophage data from literature reports. A web interface for prophage scan based on this method is available at http://bicmku.in:8082/prophagedb/dra.html. Two hundred bacterial genomes which do not have annotated prophages have been scanned for prophage regions using this method. CONCLUSIONS: The relative dinucleotide distribution difference helps detect prophage regions in genome sequences. The usefulness of this method is seen in the identification of 461 highly probable loci pertaining to prophages which have not been annotated so earlier. This work emphasizes the need to extend the efforts to detect and annotate prophage elements in genome sequences.

  11. Digital Rock Simulation of Flow in Carbonate Samples

    Science.gov (United States)

    Klemin, D.; Andersen, M.

    2014-12-01

    Reservoir engineering has becomes more complex to deal with current challenges, so core analysts must understand and model pore geometries and fluid behaviors at pores scales more rapidly and realistically. We introduce an industry-unique direct hydrodynamic pore flow simulator that operates on pore geometries from digital rock models obtained using microCT or 3D scanning electron microscope (SEM) images. The PVT and rheological models used in the simulator represent real reservoir fluids. Fluid-solid interactions are introduced using distributed micro-scale wetting properties. The simulator uses density functional approach applied for hydrodynamics of complex systems. This talk covers selected applications of the simulator. We performed microCT scanning of six different carbonate rock samples from homogeneous limestones to vuggy carbonates. From these, we constructed digital rock models representing pore geometries for the simulator. We simulated nonreactive tracer flow in all six digital models using a digital fluid description that included a passive tracer solution. During the simulation, we evaluated the composition of the effluent. Results of tracer flow simulations corresponded well with experimental data of nonreactive tracer floods for the same carbonate rock types. This simulation data of the non-reactive tracer flow can be used to calculate the volume of the rock accessible by the fluid, which can be further used to predict response of a porous medium to a reactive fluid. The described digital core analysis workflow provides a basis for a wide variety of activities, including input to design acidizing jobs and evaluating treatment efficiency and EOR economics. Digital rock multiphase flow simulations of a scanned carbonate rock evaluated the effect of wettability on flow properties. Various wetting properties were tested: slightly oil wet, slightly water wet, and water wet. Steady-state relative permeability simulations yielded curves for all three

  12. Computer-Aided Detection of Kidney Tumor on Abdominal Computed Tomography Scans

    International Nuclear Information System (INIS)

    Kim, D.Y.; Park, J.W.

    2004-01-01

    Purpose: To implement a computer-aided detection system for kidney segmentation and kidney tumor detection on abdominal computed tomography (CT) scans. Material and Methods: Abdominal CT images were digitized with a film digitizer, and a gray-level threshold method was used to segment the kidney. Based on texture analysis performed on sample images of kidney tumors, a portion of the kidney tumor was selected as seed region for start point of the region-growing process. The average and standard deviations were used to detect the kidney tumor. Starting at the detected seed region, the region-growing method was used to segment the kidney tumor with intensity values used as an acceptance criterion for a homogeneous test. This test was performed to merge the neighboring region as kidney tumor boundary. These methods were applied on 156 transverse images of 12 cases of kidney tumors scanned using a G.E. Hispeed CT scanner and digitized with a Lumisys LS-40 film digitizer. Results: The computer-aided detection system resulted in a kidney tumor detection sensitivity of 85% and no false-positive findings. Conclusion: This computer-aided detection scheme was useful for kidney tumor detection and gave the characteristics of detected kidney tumors

  13. Comparison of vessel contrast measured with a scanning-beam digital x-ray system and an image intensifier/television system

    International Nuclear Information System (INIS)

    Speidel, Michael A.; Wilfley, Brian P.; Heanue, Joseph A.; Betts, Timothy D.; Van Lysel, Michael S.

    2001-01-01

    Vessel contrast was measured in the fluoroscopic images produced by a scanning-beam digital x-ray (SBDX) system and an image intensifier/television (II/TV) based system. The SBDX system electronically scans a series of pencil x-ray beams across the patient, each of which is directed at a distant small-area detector array. The reduction in detected scatter achieved with this geometry was expected to provide an increase in image contrast. Vessel contrast was evaluated from images of a phantom containing iodinated tubes. The vessels were inserted into an acrylic stack to provide a patient-mimicking scattering medium. Vessel diameter ranged from 0.3 to 3.1 mm. Images were acquired at 100 kVp with the SBDX and II/TV systems and averaged to reduce x-ray noise. The II/TV system was operated in the 6-in. image intensifier mode with an anti-scatter grid. The increase in contrast in the SBDX images, expressed as a ratio of the measured SBDX and II/TV contrasts, ranged from 1.63 to 1.79 for individual vessels. This agreed well with a prediction of the contrast improvement ratio for this experiment, based on measurements of the scatter fraction, object-plane line spread functions, and consideration of the source spectrum and detector absorption properties. The predicted contrast improvement ratio for SBDX relative to II/TV images was 1.62 to 1.77

  14. Evaluation of proximal caries in images resulting from different modes of radiographic digitalization.

    Science.gov (United States)

    Xavier, C R G; Araujo-Pires, Ana Claudia; Poleti, M L; Rubira-Bullen, I R F; Ferreira, O; Capelozza, A L A

    2011-09-01

    The aim of this study was to evaluate the performances of observers in diagnosing proximal caries in digital images obtained from digital bitewing radiographs using two scanners and four digital cameras in Joint Photographic Experts Group (JPEG) and tagged image file format (TIFF) files, and comparing them with the original conventional radiographs. In total, 56 extracted teeth were radiographed with Kodak Insight film (Eastman Kodak, Rochester, NY) in a Kaycor Yoshida X-ray device (Kaycor X-707; Yoshida Dental Manufacturing Co., Tokyo, Japan) operating at 70 kV and 7 mA with an exposure time of 0.40 s. The radiographs were obtained and scanned by CanonScan D646U (Canon USA Inc., Newport News, VA) and Genius ColorPage HR7X (KYE Systems Corp. America, Doral, FL) scanners, and by Canon Powershot G2 (Canon USA Inc.), Canon RebelXT (Canon USA Inc.), Nikon Coolpix 8700 (Nikon Inc., Melville, NY), and Nikon D70s (Nikon Inc.) digital cameras in JPEG and TIFF formats. Three observers evaluated the images. The teeth were then observed under the microscope in polarized light for the verification of the presence and depth of the carious lesions. The probability of no diagnosis ranged from 1.34% (Insight film) to 52.83% (CanonScan/JPEG). The sensitivity ranged from 0.24 (Canon RebelXT/JPEG) to 0.53 (Insight film), the specificity ranged from 0.93 (Nikon Coolpix/JPEG, Canon Powershot/TIFF, Canon RebelXT/JPEG and TIFF) to 0.97 (CanonScan/TIFF and JPEG) and the accuracy ranged from 0.82 (Canon RebelXT/JPEG) to 0.91 (CanonScan/JPEG). The carious lesion diagnosis did not change in either of the file formats (JPEG and TIFF) in which the images were saved for any of the equipment used. Only the CanonScan scanner did not have adequate performance in radiography digitalization for caries diagnosis and it is not recommended for this purpose.

  15. [Diagnoses of rice nitrogen status based on characteristics of scanning leaf].

    Science.gov (United States)

    Zhu, Jin-Xia; Deng, Jin-Song; Shi, Yuan-Yuan; Chen, Zhu-Lu; Han, Ning; Wang, Ke

    2009-08-01

    In the present research, the scanner was adopted as the digital image sensor, and a new method to diagnose the status of rice based on image processing technology was established. The main results are as follows: (1) According to the analysis of relations between leaf percentage nitrogen contents and color parameter, the sensitive color parameters were abstracted as B, b, b/(r+g), b/r and b/g. The leaf position (vertical spatial variation) effects on leaf chlorophyll contents were investigated, and the third fully expanded leaf was selected as the diagnosis leaf. (2) Field ground data such as ASD were collected simultaneously. Then study on the relationships between scanned leaf color characteristics and hyperspectral was carried out. The results indicated that the diagnosis of nitrogen status based on the scanned color characteristic is able to partly reflect the hyperspectral properties. (3) The leaf color and shape features were intergrated and the model of diagnosing the status of rice was established with calculated at YIQ color system. The distinct accuracy of nitrogen status was as follows: N0: 74.9%; N1 : 52%; N2 : 84.7%; N3 : 75%. The preliminary study showed that the methodology has been proved successful in this study and provides the potential to monitor nitrogen status in a cost-effective and accurate way based on the scanned digital image. Although, some confusion exists, with rapidly increasing resolution of digital platform and development of digital image technology, it will be more convenient for larger farms that can afford to use mechanized systems for site-specific nutrient management. Moreover, deeper theory research and practice experiment should be needed in the future.

  16. 3D body scanning technology for fashion and apparel industry

    Science.gov (United States)

    D'Apuzzo, Nicola

    2007-01-01

    This paper presents an overview of 3D body scanning technologies with applications to the fashion and apparel industry. Complete systems for the digitization of the human body exist since more than fifteen years. One of the main users of this technology with application in the textile field was the military industry. In fact, body scanning technology is being successfully employed since many years in military bases for a fast selection of the correct size of uniforms for the entire staff. Complete solutions were especially developed for this field of application. Many different research projects were issued for the exploitation of the same technology in the commercial field. Experiments were performed and start-up projects are to time running in different parts of the world by installing full body scanning systems in various locations such as shopping malls, boutiques or dedicated scanning centers. Everything is actually ready to be exploited and all the required hardware, software and solutions are available: full body scanning systems, software for the automatic and reliable extraction of body measurements, e-kiosk and web solutions for the presentation of garments, high-end and low-end virtual-try-on systems. However, complete solutions in this area have still not yet found the expected commercial success. Today, with the on-going large cost reduction given by the appearance of new competitors, methods for digitization of the human body becomes more interesting for the fashion and apparel industry. Therefore, a large expansion of these technologies is expected in the near future. To date, different methods are used commercially for the measurement of the human body. These can be divided into three major distinguished groups: laser-scanning, projection of light patterns, combination modeling and image processing. The different solutions have strengths and weaknesses that profile their suitability for specific applications. This paper gives an overview of their

  17. 3D scanning and printing skeletal tissues for anatomy education.

    Science.gov (United States)

    Thomas, Daniel B; Hiscox, Jessica D; Dixon, Blair J; Potgieter, Johan

    2016-09-01

    Detailed anatomical models can be produced with consumer-level 3D scanning and printing systems. 3D replication techniques are significant advances for anatomical education as they allow practitioners to more easily introduce diverse or numerous specimens into classrooms. Here we present a methodology for producing anatomical models in-house, with the chondrocranium cartilage from a spiny dogfish (Squalus acanthias) and the skeleton of a cane toad (Rhinella marina) as case studies. 3D digital replicas were produced using two consumer-level scanners and specimens were 3D-printed with selective laser sintering. The fidelity of the two case study models was determined with respect to key anatomical features. Larger-scale features of the dogfish chondrocranium and frog skeleton were all well-resolved and distinct in the 3D digital models, and many finer-scale features were also well-resolved, but some more subtle features were absent from the digital models (e.g. endolymphatic foramina in chondrocranium). All characters identified in the digital chondrocranium could be identified in the subsequent 3D print; however, three characters in the 3D-printed frog skeleton could not be clearly delimited (palatines, parasphenoid and pubis). Characters that were absent in the digital models or 3D prints had low-relief in the original scanned specimen and represent a minor loss of fidelity. Our method description and case studies show that minimal equipment and training is needed to produce durable skeletal specimens. These technologies support the tailored production of models for specific classes or research aims. © 2016 Anatomical Society.

  18. Cost analysis of operating an all-digital radiology department

    International Nuclear Information System (INIS)

    Arenson, R.L.; Soshadri, S.B.; DeSimone, D.; Hiss, S.S.

    1988-01-01

    Using the current film system as a baseline, this study analyzes the cost of digital acquisition, transmission, archiving, and display of all images generated in our department. Two approaches are considered: (1) conventional x-ray films are digitized with a laser scanning film digitizer; (2) images are captured with a direct digital receptor and no film is created. In both approaches, images from digital modalities are acquired directly from the scanners. The cost of equipment and its maintenance, film, supplies, storage space, operations, personnel, and so forth are analyzed for all approaches. The annual cost of operating the film system is $2.5 million. The estimated annual cost is $2.3 million for the first digital approach, $1.8 million for the second. This analysis demonstrates that these digital approaches can be cost-effective, viable alternatives to film-bases systems

  19. Fluorescence in situ hybridization on human metaphase chromosomes detected by near-field scanning optical microscopy

    NARCIS (Netherlands)

    Moers, M.H.P.; Moers, M.H.P.; Kalle, W.H.J.; Kalle, W.H.J.; Ruiter, A.G.T.; Wiegant, J.C.A.G.; Raap, A.K.; Greve, Jan; de Grooth, B.G.; van Hulst, N.F.

    1996-01-01

    Fluorescence in situ hybridization o­n human metaphase chromosomes is detected by near-field scanning optical microscopy. This combination of cytochemical and scanning probe techniques enables the localization and identification of several fluorescently labelled genomic DNA fragments o­n a single

  20. New Snail Mail Scanning Service

    CERN Multimedia

    2012-01-01

    Modernisation does not stop at the CERN postal service (GS/PS). “With more and more digitisation and the prevalence of e-mail throughout the site, we were hoping to provide more timely delivery of letters and make further saving in resources”, said Tueri Datta, head of GS/PS.   Instead of the standard delivery to your P.O. box, the CERN postal service will digitally scan all letters and books up to 100 pages on reception. These scans will subsequently be sent via e-mail to the corresponding recipient as PDF (Portable Data Format - you will need to install “Acrobat Reader” on your PC). Express mail will be handled with priority. Users without a valid CERN mailbox can register at mail.scan.service@cern.ch in order to have their letters read to them via the phone line (we are currently investigating whether we can use the voices of the last five DGs).   This service will start on 1st April 2012 on the Meyrin site and will gradually replace th...

  1. 1:100k Digital Raster Graphic - Collars Removed

    Data.gov (United States)

    Minnesota Department of Natural Resources — A digital raster graphic (DRG) is a scanned image of an U.S. Geological Survey (USGS) standard series topographic map, including all map collar information. The...

  2. Digital subtraction angiography in patients with central vertigo

    International Nuclear Information System (INIS)

    Inamori, Toru; Takayasu, Yukio; Umetani, Yoshio; Taruoka, Akinori.

    1985-01-01

    Digital subtraction angiography (DSA) is a recently developed non-invasive intravenous angiography which has become possible through real time digital subtraction of x-ray transmission data from an image intensifier and television system. The output signals of the image intensifier-television camera system are digitized by an analog-digital converter. The digital information, 512x512 pixels and 9 bits deep, is fed into the image processing assembly after logarithmic amplification, where 2-8 frames are added and subtracted from mask images for the final digital images. Intravenous digital subtraction angiography was performed in 21 patients with intractable dizzy spells of central origin resistant to treatment. These patients showed some signs of CNS disturbance, although there were no significant findings on CT scans. Surprisingly, findings were abnormal in 14 of 21 patients (66.7%). DSA is, therefore, considered to be an important aid in the diagnosis of vertigo of the central type. (J.P.N.)

  3. Accuracy of five intraoral scanners compared to indirect digitalization.

    Science.gov (United States)

    Güth, Jan-Frederik; Runkel, Cornelius; Beuer, Florian; Stimmelmayr, Michael; Edelhoff, Daniel; Keul, Christine

    2017-06-01

    Direct and indirect digitalization offer two options for computer-aided design (CAD)/ computer-aided manufacturing (CAM)-generated restorations. The aim of this study was to evaluate the accuracy of different intraoral scanners and compare them to the process of indirect digitalization. A titanium testing model was directly digitized 12 times with each intraoral scanner: (1) CS 3500 (CS), (2) Zfx Intrascan (ZFX), (3) CEREC AC Bluecam (BLU), (4) CEREC AC Omnicam (OC) and (5) True Definition (TD). As control, 12 polyether impressions were taken and the referring plaster casts were digitized indirectly with the D-810 laboratory scanner (CON). The accuracy (trueness/precision) of the datasets was evaluated by an analysing software (Geomagic Qualify 12.1) using a "best fit alignment" of the datasets with a highly accurate reference dataset of the testing model, received from industrial computed tomography. Direct digitalization using the TD showed the significant highest overall "trueness", followed by CS. Both performed better than CON. BLU, ZFX and OC showed higher differences from the reference dataset than CON. Regarding the overall "precision", the CS 3500 intraoral scanner and the True Definition showed the best performance. CON, BLU and OC resulted in significantly higher precision than ZFX did. Within the limitations of this in vitro study, the accuracy of the ascertained datasets was dependent on the scanning system. The direct digitalization was not superior to indirect digitalization for all tested systems. Regarding the accuracy, all tested intraoral scanning technologies seem to be able to reproduce a single quadrant within clinical acceptable accuracy. However, differences were detected between the tested systems.

  4. GERAÇÃO DE MODELO DIGITAL DE TERRENO POR MEIO DA FILTRAGEM DE DADOS OBTIDOS POR VARREDURA A LASER UTILIZANDO UM MÉTODO BASEADO NO PRINCÍPIO DA DECLIVIDADE

    Directory of Open Access Journals (Sweden)

    Wallace Felipe Francisco Cardoso

    2014-06-01

    Full Text Available Due the advances in the technology of laser scanning systems, research in several countries have been initiated with the aim of exploring the recently technological resources developed. The result obtained by laser scanning systems provided the details of regions features and update many of the national territories models. The data generated by laser scanning match the altimetry data set named as Digital Elevation Model. This model derivation, when containing only terrain features, is called Digital Terrain Model. However, the Digital Terrain Models cannot be easily generated by laser scanning. In general, the Digital Terrain Models are derived from Digital Elevation Models applying filtering methods. This work objective is to adapt a Digital Elevation Model filtering method and discuss the results obtained.

  5. Alignment-free comparative genomic screen for structured RNAs using coarse-grained secondary structure dot plots

    DEFF Research Database (Denmark)

    Kato, Yuki; Gorodkin, Jan; Havgaard, Jakob Hull

    2017-01-01

    . Methods: Here we present a fast and efficient method, DotcodeR, for detecting structurally similar RNAs in genomic sequences by comparing their corresponding coarse-grained secondary structure dot plots at string level. This allows us to perform an all-against-all scan of all window pairs from two genomes...... without alignment. Results: Our computational experiments with simulated data and real chromosomes demonstrate that the presented method has good sensitivity. Conclusions: DotcodeR can be useful as a pre-filter in a genomic comparative scan for structured RNAs....

  6. Evaluation of digital model accuracy and time-dependent deformation of alginate impressions.

    Science.gov (United States)

    Cesur, M G; Omurlu, I K; Ozer, T

    2017-09-01

    The aim of this study was to evaluate the accuracy of digital models produced with the three-dimensional dental scanner, and to test the dimensional stability of alginate impressions for durations of immediately (T0), 1 day (T1), and 2 days (T2). A total of sixty impressions were taken from a master model with an alginate, and were poured into plaster models in three different storage periods. Twenty impressions were directly scanned (negative digital models), after which plaster models were poured and scanned (positive digital models) immediately. The remaining 40 impressions were poured after 1 and 2 days. In total, 9 points and 11 linear measurements were used to analyze the plaster models, and negative and positive digital models. Time-dependent deformation of the alginate impressions and the accuracy of the conventional plaster models and digital models were evaluated separately. Plaster models, negative and positive digital models showed significant differences in nearly all measurements at T (0), T (1), and T (2) times (P 0.05), but they demonstrated statistically significant differences at T (2) time (P impressions is practicable method for orthodontists.

  7. Digital Raster Graphics (DRG) UTM NAD 83 Clipped

    Data.gov (United States)

    Kansas Data Access and Support Center — The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid. For display...

  8. Digital Raster Graphics (DRG) UTM NAD 27 Clipped

    Data.gov (United States)

    Kansas Data Access and Support Center — The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid. For display...

  9. Assessment of residual coronal tooth structure postendodontic cavity preparation using digital dental impressions and micro-computed tomography.

    Science.gov (United States)

    Al-Nuaimi, Nassr; Patel, Shanon; Foschi, Federico; Mannocci, Francesco; Austin, Rupert S

    To evaluate the in vitro accuracy of digital impressions for three-dimensional (3D) volumetric measurement of residual coronal tooth structure postendodontic cavity preparation, with reference to micro-computed tomography (μCT). Quantification of the accuracy and precision of the intraoral digital scanner (3M True Definition Scanner - IOS) was performed using a metrology gauge block and a profilometric calibration model. Thirty-four human extracted molars with endodontic access cavities were scanned using both intraoral scanning (test scanner) in high-resolution mode, and µCT (reference scanner: GE Locus SP μCT scanner) in high- (HiResCT) and low- (LoResCT) resolution modes. Comparisons of volumetric accuracy and 3D profilometric deviations were performed using surface metrology software. One-way repeated measures analysis of variance (ANOVA), in combination with the Bonferroni post hoc test, was implemented to compare the differences in volume measurements between scanning methods. Digital scanning revealed smaller volume measurements by 1.36% and 0.68% compared to HiResCT and LoResCT, respectively. There was a statistically significant difference in the volumetric measurements obtained from the IOS scanner and both HiResCT and LoResCT scans (P digital scanner was able to reliably measure the extra- and intracoronal aspect of the endodontically accessed tooth.

  10. Investigation of renovascular hypertension with 99mTC-DTPA dynamic renal scanning and digital subtraction angiography

    International Nuclear Information System (INIS)

    Stavraka-Kakavakis, A.; Vlontjou, E.; Apostolopoulos, D.; Mourikis, D.; Venetsanakis, N.; Lazarou, S.; Vlahos, L.

    1989-01-01

    Sixty-four selected hypertensive patients, aged 17-45 years, were evaluated for renovascular hypertension. They were studied with 99m TC-DTPA dynamic renal scanning (DRS) and intravenous digital subtraction angiography (IV-DSA). Intra-arterial DSA was further performed to demonstrate renal vascular anatomy in all disputable cases. Agreement of diagnosis occurred in 58 patients (32 with renal artery stenosis). There was one false positive with DRS and one false positive with IV-DSA. In another four patients with proven renovascular disease, IV-DSA was positive while DRS negative, but in two of them the stenotic lesion was considered insignificant, as they failed to respond to percutaneous transluminal dilatation (PTA). In contrast, nearly all patients whose hypertension improved after PTA or surgery had positive DRS and greater than 40% reduction of relative function of the affected kidney. IV-DSA yielded better results than DRS in the detection of renal arterial stenosis (especially whenever bilateral stenosis or rich collateral circulation was present), but DRS showed better correlation with the functional significance of a certain vascular abnormality. Thus the combination of the two methods seems to be a reasonable diagnostic approach to hypertensive patients with the aim of selecting those with curable hypertension due to renal vascular disease. (orig.)

  11. eCTG: an automatic procedure to extract digital cardiotocographic signals from digital images.

    Science.gov (United States)

    Sbrollini, Agnese; Agostinelli, Angela; Marcantoni, Ilaria; Morettini, Micaela; Burattini, Luca; Di Nardo, Francesco; Fioretti, Sandro; Burattini, Laura

    2018-03-01

    Cardiotocography (CTG), consisting in the simultaneous recording of fetal heart rate (FHR) and maternal uterine contractions (UC), is a popular clinical test to assess fetal health status. Typically, CTG machines provide paper reports that are visually interpreted by clinicians. Consequently, visual CTG interpretation depends on clinician's experience and has a poor reproducibility. The lack of databases containing digital CTG signals has limited number and importance of retrospective studies finalized to set up procedures for automatic CTG analysis that could contrast visual CTG interpretation subjectivity. In order to help overcoming this problem, this study proposes an electronic procedure, termed eCTG, to extract digital CTG signals from digital CTG images, possibly obtainable by scanning paper CTG reports. eCTG was specifically designed to extract digital CTG signals from digital CTG images. It includes four main steps: pre-processing, Otsu's global thresholding, signal extraction and signal calibration. Its validation was performed by means of the "CTU-UHB Intrapartum Cardiotocography Database" by Physionet, that contains digital signals of 552 CTG recordings. Using MATLAB, each signal was plotted and saved as a digital image that was then submitted to eCTG. Digital CTG signals extracted by eCTG were eventually compared to corresponding signals directly available in the database. Comparison occurred in terms of signal similarity (evaluated by the correlation coefficient ρ, and the mean signal error MSE) and clinical features (including FHR baseline and variability; number, amplitude and duration of tachycardia, bradycardia, acceleration and deceleration episodes; number of early, variable, late and prolonged decelerations; and UC number, amplitude, duration and period). The value of ρ between eCTG and reference signals was 0.85 (P digital FHR and UC signals from digital CTG images. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Fully integrated digital GAMMA camera-computer system

    International Nuclear Information System (INIS)

    Berger, H.J.; Eisner, R.L.; Gober, A.; Plankey, M.; Fajman, W.

    1985-01-01

    Although most of the new non-nuclear imaging techniques are fully digital, there has been a reluctance in nuclear medicine to abandon traditional analog planar imaging in favor of digital acquisition and display. The authors evaluated a prototype digital camera system (GE STARCAM) in which all of the analog acquisition components are replaced by microprocessor controls and digital circuitry. To compare the relative effects of acquisition matrix size on image quality and to ascertain whether digital techniques could be used in place of analog imaging, Tc-99m bone scans were obtained on this digital system and on a comparable analog camera in 10 patients. The dedicated computer is used for camera setup including definition of the energy window, spatial energy correction, and spatial distortion correction. The display monitor, which is used for patient positioning and image analysis, is 512/sup 2/ non-interlaced, allowing high resolution imaging. Data acquisition and processing can be performed simultaneously. Thus, the development of a fully integrated digital camera-computer system with optimized display should allow routine utilization of non-analog studies in nuclear medicine and the ultimate establishment of fully digital nuclear imaging laboratories

  13. Digital Raster Graphics (DRG) UTM NAD 83 County

    Data.gov (United States)

    Kansas Data Access and Support Center — The Digital Raster Graphic (DRG) is a raster image of a scanned USGS topographic map including the collar information, georeferenced to the UTM grid and tiled by...

  14. Quantitative investigation of the effects of the scanning parameters in the digitization of EBT and EBT2 Gafchromic film dosimetry with flatbed scanners.

    Science.gov (United States)

    Hu, Yida; Ahmad, Salahuddin; Ali, Imad

    2012-01-01

    With increasing popularity and complexity of intensity-modulated radiation therapy (IMRT) delivery modalities including regular and arc therapies, there is a growing challenge for validating the accuracy of dose distributions. Gafchromic films have superior characteristics for dose verification over other conventional dosimeters. In order to optimize the use of Gafchromic films in clinical IMRT quality assurance procedures, the scanning parameters of EBT and EBT2 films with a flatbed scanner were investigated. The effects of several parameters including scanning position, orientation, uniformity, film sensitivity and optical density (OD) growth after irradiation were quantified. The profiles of the EBT and EBT2 films had a noise level of 0.6% and 0.7%, respectively. Considerable orientation dependence was observed and the scanner value difference between landscape and portrait modes were about 12% and 10% for EBT and EBT2 films, respectively. The highest response sensitivity was observed using digitized red color images of the EBT2 film scanned with landscape mode. The total system non-uniformity composed of contributions from the film and the scanner was less than 1.7%. OD variations showed that EBT gray scale grew slower, however, reached higher growth values of 15% when compared with EBT2 gray scale which grew 12% after a long time (480 hours) post-irradiation. The EBT film using the red color channel showed the minimal growth where OD increased up to 3% within 3 days after irradiation, and took one week to stabilize.

  15. Genomic futures of prenatal screening: ethical reflection.

    Science.gov (United States)

    Dondorp, W J; Page-Christiaens, G C M L; de Wert, G M W R

    2016-05-01

    The practice of prenatal screening is undergoing important changes as a result of the introduction of genomic testing technologies at different stages of the screening trajectory. It is expected that eventually it will become possible to routinely obtain a comprehensive 'genome scan' of all fetuses. Although this will still take several years, there are clear continuities between present developments and this future scenario. As this review shows, behind the still limited scope of screening for common aneuploidies, a rapid widening of the range of conditions tested for is already taking shape at the invasive testing stage. But the continuities are not just technical; they are also ethical. If screening for Down's syndrome is a matter of providing autonomous reproductive choice, then why would providing the choice to have a full fetal genome scan be something entirely different? There is a clear need for a sustainable normative framework that will have to answer three challenges: the indeterminateness of the autonomy paradigm, the need to acknowledge the future child as an interested stakeholder, and the prospect of broad-scope genomic prenatal screening with a double purpose: autonomy and prevention. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  16. A Genome-Wide Methylation Study of Severe Vitamin D Deficiency in African American Adolescents

    NARCIS (Netherlands)

    Zhu, Haidong; Wang, Xiaoling; Shi, Huidong; Su, Shaoyong; Harshfield, Gregory A.; Gutin, Bernard; Snieder, Harold; Dong, Yanbin

    Objectives To test the hypothesis that changes in DNA methylation are involved in vitamin D deficiency-related immune cell regulation using an unbiased genome-wide approach combined with a genomic and epigenomic integrative approach. Study design We performed a genome-wide methylation scan using the

  17. [Precision of digital impressions with TRIOS under simulated intraoral impression taking conditions].

    Science.gov (United States)

    Yang, Xin; Sun, Yi-fei; Tian, Lei; Si, Wen-jie; Feng, Hai-lan; Liu, Yi-hong

    2015-02-18

    To evaluate the precision of digital impressions taken under simulated clinical impression taking conditions with TRIOS and to compare with the precision of extraoral digitalizations. Six #14-#17 epoxy resin dentitions with extracted #16 tooth preparations embedded were made. For each artificial dentition, (1)a silicone rubber impression was taken with individual tray, poured with type IV plaster,and digitalized with 3Shape D700 model scanner for 10 times; (2) fastened to a dental simulator, 10 digital impressions for each were taken with 3Shape TRIOS intraoral scanner. To assess the precision, best-fit algorithm and 3D comparison were conducted between repeated scan models pairwise by Geomagic Qualify 12.0, exported as averaged errors (AE) and color-coded diagrams. Non-parametric analysis was performed to compare the precisions of digital impressions and model images. The color-coded diagrams were used to show the deviations distributions. The mean of AE for digital impressions was 7.058 281 μm, which was greater than that of 4.092 363 μm for the model images (Pimpressions were no more than 10 μm, which meant that the consistency between the digital impressions was good. The deviations distribution was uniform in the model images,while nonuniform in the digital impressions with greater deviations lay mainly around the shoulders and interproximal surfaces. Digital impressions with TRIOS are of good precision and up to the clinical standard. Shoulders and interproximal surfaces scanning are more difficult.

  18. Precision digital control systems

    Science.gov (United States)

    Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.

    This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.

  19. One bacterial cell, one complete genome.

    Directory of Open Access Journals (Sweden)

    Tanja Woyke

    2010-04-01

    Full Text Available While the bulk of the finished microbial genomes sequenced to date are derived from cultured bacterial and archaeal representatives, the vast majority of microorganisms elude current culturing attempts, severely limiting the ability to recover complete or even partial genomes from these environmental species. Single cell genomics is a novel culture-independent approach, which enables access to the genetic material of an individual cell. No single cell genome has to our knowledge been closed and finished to date. Here we report the completed genome from an uncultured single cell of Candidatus Sulcia muelleri DMIN. Digital PCR on single symbiont cells isolated from the bacteriome of the green sharpshooter Draeculacephala minerva bacteriome allowed us to assess that this bacteria is polyploid with genome copies ranging from approximately 200-900 per cell, making it a most suitable target for single cell finishing efforts. For single cell shotgun sequencing, an individual Sulcia cell was isolated and whole genome amplified by multiple displacement amplification (MDA. Sanger-based finishing methods allowed us to close the genome. To verify the correctness of our single cell genome and exclude MDA-derived artifacts, we independently shotgun sequenced and assembled the Sulcia genome from pooled bacteriomes using a metagenomic approach, yielding a nearly identical genome. Four variations we detected appear to be genuine biological differences between the two samples. Comparison of the single cell genome with bacteriome metagenomic sequence data detected two single nucleotide polymorphisms (SNPs, indicating extremely low genetic diversity within a Sulcia population. This study demonstrates the power of single cell genomics to generate a complete, high quality, non-composite reference genome within an environmental sample, which can be used for population genetic analyzes.

  20. One Bacterial Cell, One Complete Genome

    Energy Technology Data Exchange (ETDEWEB)

    Woyke, Tanja; Tighe, Damon; Mavrommatis, Konstantinos; Clum, Alicia; Copeland, Alex; Schackwitz, Wendy; Lapidus, Alla; Wu, Dongying; McCutcheon, John P.; McDonald, Bradon R.; Moran, Nancy A.; Bristow, James; Cheng, Jan-Fang

    2010-04-26

    While the bulk of the finished microbial genomes sequenced to date are derived from cultured bacterial and archaeal representatives, the vast majority of microorganisms elude current culturing attempts, severely limiting the ability to recover complete or even partial genomes from these environmental species. Single cell genomics is a novel culture-independent approach, which enables access to the genetic material of an individual cell. No single cell genome has to our knowledge been closed and finished to date. Here we report the completed genome from an uncultured single cell of Candidatus Sulcia muelleri DMIN. Digital PCR on single symbiont cells isolated from the bacteriome of the green sharpshooter Draeculacephala minerva bacteriome allowed us to assess that this bacteria is polyploid with genome copies ranging from approximately 200?900 per cell, making it a most suitable target for single cell finishing efforts. For single cell shotgun sequencing, an individual Sulcia cell was isolated and whole genome amplified by multiple displacement amplification (MDA). Sanger-based finishing methods allowed us to close the genome. To verify the correctness of our single cell genome and exclude MDA-derived artifacts, we independently shotgun sequenced and assembled the Sulcia genome from pooled bacteriomes using a metagenomic approach, yielding a nearly identical genome. Four variations we detected appear to be genuine biological differences between the two samples. Comparison of the single cell genome with bacteriome metagenomic sequence data detected two single nucleotide polymorphisms (SNPs), indicating extremely low genetic diversity within a Sulcia population. This study demonstrates the power of single cell genomics to generate a complete, high quality, non-composite reference genome within an environmental sample, which can be used for population genetic analyzes.

  1. Digital Photography--a Question of Ethics.

    Science.gov (United States)

    Meltzer, Bonnie

    1996-01-01

    Discusses reasons for computer manipulation of photographs and the need to educate students about the ethics involving digital scanning. Focuses on ownership, copyrights, reasons for changing a photograph, reader-interpretation, and the context in which the photograph is used. Suggests a photo illustration project to teach students about these…

  2. Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition.

    Science.gov (United States)

    Rhee, Ye-Kyu; Huh, Yoon-Hyuk; Cho, Lee-Ra; Park, Chan-Jin

    2015-12-01

    The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (Pimpression and the smallest difference was seen between dual-arch and full-arch impression. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P.05).

  3. Compaction bands in shale revealed through digital volume correlation of time-resolved X-ray tomography scans

    Science.gov (United States)

    McBeck, J.; Kobchenko, M.; Hall, S.; Tudisco, E.; Cordonnier, B.; Renard, F.

    2017-12-01

    Previous studies have identified compaction bands primarily within sandstones, and in fewer instances, within other porous rocks and sediments. Using Digital Volume Correlation (DVC) of X-ray microtomography scans, we find evidence of localized zones of high axial contraction that form tabular structures sub-perpendicular to maximum compression, σ1, in Green River shale. To capture in situ strain localization throughout loading, two shale cores were deformed in the HADES triaxial deformation apparatus installed on the X-ray microtomography beamline ID19 at the European Synchrotron Radiation Facility. In these experiments, we increase σ1 in increments of two MPa, with constant confining pressure (20 MPa), until the sample fails in macroscopic shear. After each stress step, a 3D image of the sample inside the rig is acquired at a voxel resolution of 6.5 μm. The evolution of lower density regions within 3D reconstructions of linear attenuation coefficients reveal the development of fractures that fail with some opening. If a fracture produces negligible dilation, it may remain undetected in image segmentation of the reconstructions. We use the DVC software TomoWarp2 to identify undetected fractures and capture the 3D incremental displacement field between each successive pair of microtomography scans acquired in each experiment. The corresponding strain fields reveal localized bands of high axial contraction that host minimal shear strain, and thus match the kinematic definition of compaction bands. The bands develop sub-perpendicular to σ1 in the two samples in which pre-existing bedding laminations were oriented parallel and perpendicular to σ1. As the shales deform plastically toward macroscopic shear failure, the number of bands and axial contraction within the bands increase, while the spacing between the bands decreases. Compaction band development accelerates the rate of overall axial contraction, increasing the mean axial contraction throughout the sample

  4. Digital versus conventional implant impressions for partially edentulous arches: An evaluation of accuracy.

    Science.gov (United States)

    Marghalani, Amin; Weber, Hans-Peter; Finkelman, Matthew; Kudara, Yukio; El Rafie, Khaled; Papaspyridakos, Panos

    2018-04-01

    To the authors' knowledge, while accuracy outcomes of the TRIOS scanner have been compared with conventional impressions, no available data are available regarding the accuracy of digital scans with the Omnicam and True Definition scanners versus conventional impressions for partially edentulous arches. The purpose of this in vitro study was to compare the accuracy of digital implant scans using 2 different intraoral scanners (IOSs) with that of conventional impressions for partially edentulous arches. Two partially edentulous mandibular casts with 2 implant analogs with a 30-degree angulation from 2 different implant systems (Replace Select RP; Nobel Biocare and Tissue level RN; Straumann) were used as controls. Sixty digital models were made from these 2 definitive casts in 6 different groups (n=10). Splinted implant-level impression procedures followed by digitization were used to produce the first 2 groups. The next 2 groups were produced by digital scanning with Omnicam. The last 2 groups were produced by digital scanning with the True Definition scanner. Accuracy was evaluated by superimposing the digital files of each test group onto the digital file of the controls with inspection software. The difference in 3-dimensional (3D) deviations (median ±interquartile range) among the 3 impression groups for Nobel Biocare was statistically significant among all groups (P3D deviations among the 3 impression groups for Straumann was statistically significant among all groups (P=.003), except for the conventional impression (22 ±5 μm) and True Definition (17 ±5 μm) groups; the median ±interquartile range for the Omnicam group was 26 ±15 μm. The difference in 3D deviations between the 2 implant systems was significant for the Omnicam (P=.011) and conventional (Pimpression techniques but not for the True Definition technique (P=.247). Within the limitations of this study, both the impression technique and the implant system affected accuracy. The True

  5. Translate rotate scanning method for X-ray imaging

    International Nuclear Information System (INIS)

    Eberhard, J.W.; Kwog Cheong Tam.

    1990-01-01

    Rapid x-ray inspection of objects larger than an x-ray detector array is based on a translate rotate scanning motion of the object related to the fan beam source and detector. The scan for computerized tomography imaging is accomplished by rotating the object through 360 degrees at two or more positions relative to the source and detector array, in moving to another position the object is rotated and the object or source and detector are translated. A partial set of x-ray data is acquired at every position which are combined to obtain a full data set for complete image reconstruction. X-ray data for digital radiography imaging is acquired by scanning the object vertically at a first position at one view angle, rotating and translating the object relative to the source and detector to a second position, scanning vertically, and so on to cover the object field of view, and combining the partial data sets. (author)

  6. Method and apparatus for performing digital intravenous subtraction angiography

    International Nuclear Information System (INIS)

    Stein, J.A.

    1986-01-01

    This invention relates to digital intravenous subtraction angiography (DISA), and more particularly concerns novel apparatus and techniques for providing high resolution angiograms with equipment that coacts with existing standard medical X-ray equipment. A typical medical X-ray generator provides low mA, continuous X-ray exposures illuminating a standard image intensifier producing an image scanned by a conventional television camera to produce a video signal. An analog-to-digital converter digitizes the signal, and adding means adds the digital frame signals together in real time to provide an intermediate digital signal representing the addition of 5 to 20 frames. Digital storage means store the intermediate image signals. Preferably there are two system memories with means for summing a subsequent intermediate image in the second memory while a previously-formed intermediate image is being transferred to disk storage

  7. Digital amnesia and the future tourist

    Directory of Open Access Journals (Sweden)

    Chris Greenwood

    2017-04-01

    Full Text Available Purpose – The purpose of this paper is to examine the phenomenon of digital amnesia and its influence on the future tourist. Design/methodology/approach – A trend paper based on environmental scanning and speculative future analysis. Findings – The phenomena of digital amnesia are established. The growth of digital platforms and the consumer’s reliance is exponential. The implications for the future tourist in terms of decision making, the influence of marketing messaging and potentially the recall and reimagining of authentic experience will be significant in the future. Practical implications – Subject to the signals of change, should consumer’s reliance on digital platforms for the storing of information and memories continue to grow this has implications on how tourism businesses engage with their customers, influence and inform their marketing and how destinations would be reimagined based on the recall of their visitors. Originality/value – The trend of digital amnesia is an established and well-documented phenomenon. The development of the trend to consider the implications for the future tourism industry based a growing dependence on digital platforms is the focus of this paper.

  8. Natural History Specimen Digitization: Challenges and Concerns

    Directory of Open Access Journals (Sweden)

    Ana Vollmar

    2010-10-01

    Full Text Available A survey on the challenges and concerns invovled with digitizing natural history specimens was circulated to curators, collections managers, and administrators in the natural history community in the Spring of 2009, with over 200 responses received. The overwhelming barrier to digitizing collections was a lack of funding, based on a limited number of sources, leaving institutions mostly responsible for providing the necessary support. The uneven digitization landscape leads to a patchy accumulation of records at varying qualities, and based on different priorities, ulitimately influencing the data's fitness for use. The survey also found that although the kind of specimens found in collections and their storage can be quite varible, there are many similar challenges when digitizing including imaging, automated text scanning and parsing, geo-referencing, etc. Thus, better communication between domains could foster knowledge on digitization leading to efficiencies that could be disseminated through documentation of best practices and training.

  9. Application of intra-oral dental scanners in the digital workflow of implantology.

    Directory of Open Access Journals (Sweden)

    Wicher J van der Meer

    Full Text Available Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared.A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned with three intra-oral scanners: the CEREC (Sirona, the iTero (Cadent and the Lava COS (3M. In software the digital files were imported and the distance between the centres of the cylinders and the angulation between the cylinders was assessed. These values were compared to the measurements made on a high accuracy 3D scan of the master model.The distance errors were the smallest and most consistent for the Lava COS. The distance errors for the Cerec were the largest and least consistent. All the angulation errors were small.The Lava COS in combination with a high accuracy scanning protocol resulted in the smallest and most consistent errors of all three scanners tested when considering mean distance errors in full arch impressions both in absolute values and in consistency for both measured distances. For the mean angulation errors, the Lava COS had the smallest errors between cylinders 1-2 and the largest errors between cylinders 1-3, although the absolute difference with the smallest mean value (iTero was very small (0,0529°. An expected increase in distance and/or angular errors over the length of the arch due to an accumulation of registration errors of the patched 3D surfaces could be observed in this study design, but the effects were statistically not significant.For making impressions of implant cases for digital workflows, the most accurate scanner with the scanning protocol that will ensure the most accurate digital impression should be used. In our study model that was the Lava COS with the high accuracy scanning protocol.

  10. StarScan: a web server for scanning small RNA targets from degradome sequencing data.

    Science.gov (United States)

    Liu, Shun; Li, Jun-Hao; Wu, Jie; Zhou, Ke-Ren; Zhou, Hui; Yang, Jian-Hua; Qu, Liang-Hu

    2015-07-01

    Endogenous small non-coding RNAs (sRNAs), including microRNAs, PIWI-interacting RNAs and small interfering RNAs, play important gene regulatory roles in animals and plants by pairing to the protein-coding and non-coding transcripts. However, computationally assigning these various sRNAs to their regulatory target genes remains technically challenging. Recently, a high-throughput degradome sequencing method was applied to identify biologically relevant sRNA cleavage sites. In this study, an integrated web-based tool, StarScan (sRNA target Scan), was developed for scanning sRNA targets using degradome sequencing data from 20 species. Given a sRNA sequence from plants or animals, our web server performs an ultrafast and exhaustive search for potential sRNA-target interactions in annotated and unannotated genomic regions. The interactions between small RNAs and target transcripts were further evaluated using a novel tool, alignScore. A novel tool, degradomeBinomTest, was developed to quantify the abundance of degradome fragments located at the 9-11th nucleotide from the sRNA 5' end. This is the first web server for discovering potential sRNA-mediated RNA cleavage events in plants and animals, which affords mechanistic insights into the regulatory roles of sRNAs. The StarScan web server is available at http://mirlab.sysu.edu.cn/starscan/. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  11. RTSPM: real-time Linux control software for scanning probe microscopy.

    Science.gov (United States)

    Chandrasekhar, V; Mehta, M M

    2013-01-01

    Real time computer control is an essential feature of scanning probe microscopes, which have become important tools for the characterization and investigation of nanometer scale samples. Most commercial (and some open-source) scanning probe data acquisition software uses digital signal processors to handle the real time data processing and control, which adds to the expense and complexity of the control software. We describe here scan control software that uses a single computer and a data acquisition card to acquire scan data. The computer runs an open-source real time Linux kernel, which permits fast acquisition and control while maintaining a responsive graphical user interface. Images from a simulated tuning-fork based microscope as well as a standard topographical sample are also presented, showing some of the capabilities of the software.

  12. Introduction of the digitization software GDgraph

    International Nuclear Information System (INIS)

    Chen Guochang; Jin Yongli; Wang Jimin

    2015-01-01

    The evaluators and experimenters always desire to have full and latest experimental data sets. However, the data are often published as figures without any numerical values for some publications or journals. Furthermore, the quality of figures is not always good enough, especially for some figures scanned from the hard copy of old publications. On the other hand, the researchers would like to retrieve the data directly from EXFOR database. Digitization of figures is only one method to obtain the numerical data and correlative uncertainty, when there are only figures available from publications. Therefore we need a digitization tool to fit the requirements from evaluation, measurement and EXFOR compilation in CNDC. Before 2000, there have no common software to digitize experimental and evaluated data. And the quality of digitization results can not fit the requirements of evaluation and measurement using the traditional coordinate paper or rule. The end of twenty century, the PC was developed so quickly that to develop a software for digitization purpose become possible. Since 1997, CNDC devotes to design and develop a software for digitization. Four years later, the first version of digitization software GDGraph was developed using VC++ and released in CNDC. Although, the functions of the 1 st version of GDGraph is fit the basic requirements of digitization only, in which can digitize one group data excluding data error, BMP image format only, and it can not randomly delete digitizing data points. However, it obtains higher quality digitizing results and efficiency than the traditional method

  13. Vascular anatomy of the liver and porta hepatis with dynamic CT scan

    International Nuclear Information System (INIS)

    Hiramatsu, Yoshihiro; Wada, Mitsuyoshi; Nakajima, Teiichi; Tonooka, Reiko; Matsumoto, Kunihiko

    1983-01-01

    Vascular anatomy of the liver and porta heaptis demonstrated by dynamic CT scan was studied Identification of the individual vessels was sometimes difficult due to slight differencies in respiratory depths among the scans. Limitation in the number of slices also made the evalution of the vascular anatomy difficult. Angiography was therefore utilized for comparison in identifying the vessels. Dynamic CT scan was proved to be usefull in demonstrating the anteroposterior relationship of the vessels and surrounding structures, which is difficult with convetional angiography without multiple projections. Three dimensional understanding of the vessels was then possible with dynamic CT scan and angiography. When combined with recently advancing digital subtraction angiography, dynamic CT scan might reduce the necessity for conventional angiography with Seldinger's technique. (author)

  14. Genome complexity, robustness and genetic interactions in digital organisms

    Science.gov (United States)

    Lenski, Richard E.; Ofria, Charles; Collier, Travis C.; Adami, Christoph

    1999-08-01

    Digital organisms are computer programs that self-replicate, mutate and adapt by natural selection. They offer an opportunity to test generalizations about living systems that may extend beyond the organic life that biologists usually study. Here we have generated two classes of digital organism: simple programs selected solely for rapid replication, and complex programs selected to perform mathematical operations that accelerate replication through a set of defined `metabolic' rewards. To examine the differences in their genetic architecture, we introduced millions of single and multiple mutations into each organism and measured the effects on the organism's fitness. The complex organisms are more robust than the simple ones with respect to the average effects of single mutations. Interactions among mutations are common and usually yield higher fitness than predicted from the component mutations assuming multiplicative effects; such interactions are especially important in the complex organisms. Frequent interactions among mutations have also been seen in bacteria, fungi and fruitflies. Our findings support the view that interactions are a general feature of genetic systems.

  15. Patterns of positive selection in six Mammalian genomes

    DEFF Research Database (Denmark)

    Kosiol, Carolin; Vinar, Tomás; da Fonseca, Rute R

    2008-01-01

    Genome-wide scans for positively selected genes (PSGs) in mammals have provided insight into the dynamics of genome evolution, the genetic basis of differences between species, and the functions of individual genes. However, previous scans have been limited in power and accuracy owing to small...... several new lineage- and clade-specific tests to be applied. Of approximately 16,500 human genes with high-confidence orthologs in at least two other species, 400 genes showed significant evidence of positive selection (FDR... showed evidence of positive selection on particular lineages or clades. As in previous studies, the identified PSGs were enriched for roles in defense/immunity, chemosensory perception, and reproduction, but enrichments were also evident for more specific functions, such as complement-mediated immunity...

  16. Dental impressions using 3D digital scanners: virtual becomes reality.

    Science.gov (United States)

    Birnbaum, Nathan S; Aaronson, Heidi B

    2008-10-01

    The technologies that have made the use of three-dimensional (3D) digital scanners an integral part of many industries for decades have been improved and refined for application to dentistry. Since the introduction of the first dental impressioning digital scanner in the 1980s, development engineers at a number of companies have enhanced the technologies and created in-office scanners that are increasingly user-friendly and able to produce precisely fitting dental restorations. These systems are capable of capturing 3D virtual images of tooth preparations, from which restorations may be fabricated directly (ie, CAD/CAM systems) or fabricated indirectly (ie, dedicated impression scanning systems for the creation of accurate master models). The use of these products is increasing rapidly around the world and presents a paradigm shift in the way in which dental impressions are made. Several of the leading 3D dental digital scanning systems are presented and discussed in this article.

  17. Control and monitoring of doses to patients in a team of digital mammography; Control y seguimiento de las dosis a pacientes en un equipo de mamografia digital

    Energy Technology Data Exchange (ETDEWEB)

    Agulla Otero, M.; Torres Cabrera, R.; Hernando Gonzalez, I.

    2013-07-01

    In recent years is widespread use of imaging devices digital mammography. One of the advantages associated with this scanning is the ability to access a large amount of information contained in the headwaters of own digital images. The exploitation of this information allows the calculation of doses received by patients. This paper describes the methodology employed for this purpose and are presented the results of the control and monitoring of doses given in a digital mammography equipment. (Author)

  18. Genomic Signatures of Reinforcement

    Directory of Open Access Journals (Sweden)

    Austin G. Garner

    2018-04-01

    Full Text Available Reinforcement is the process by which selection against hybridization increases reproductive isolation between taxa. Much research has focused on demonstrating the existence of reinforcement, yet relatively little is known about the genetic basis of reinforcement or the evolutionary conditions under which reinforcement can occur. Inspired by reinforcement’s characteristic phenotypic pattern of reproductive trait divergence in sympatry but not in allopatry, we discuss whether reinforcement also leaves a distinct genomic pattern. First, we describe three patterns of genetic variation we expect as a consequence of reinforcement. Then, we discuss a set of alternative processes and complicating factors that may make the identification of reinforcement at the genomic level difficult. Finally, we consider how genomic analyses can be leveraged to inform if and to what extent reinforcement evolved in the face of gene flow between sympatric lineages and between allopatric and sympatric populations of the same lineage. Our major goals are to understand if genome scans for particular patterns of genetic variation could identify reinforcement, isolate the genetic basis of reinforcement, or infer the conditions under which reinforcement evolved.

  19. Genomic Signatures of Reinforcement

    Science.gov (United States)

    Goulet, Benjamin E.

    2018-01-01

    Reinforcement is the process by which selection against hybridization increases reproductive isolation between taxa. Much research has focused on demonstrating the existence of reinforcement, yet relatively little is known about the genetic basis of reinforcement or the evolutionary conditions under which reinforcement can occur. Inspired by reinforcement’s characteristic phenotypic pattern of reproductive trait divergence in sympatry but not in allopatry, we discuss whether reinforcement also leaves a distinct genomic pattern. First, we describe three patterns of genetic variation we expect as a consequence of reinforcement. Then, we discuss a set of alternative processes and complicating factors that may make the identification of reinforcement at the genomic level difficult. Finally, we consider how genomic analyses can be leveraged to inform if and to what extent reinforcement evolved in the face of gene flow between sympatric lineages and between allopatric and sympatric populations of the same lineage. Our major goals are to understand if genome scans for particular patterns of genetic variation could identify reinforcement, isolate the genetic basis of reinforcement, or infer the conditions under which reinforcement evolved. PMID:29614048

  20. Genome scan of M. tuberculosis infection and disease in Ugandans.

    Directory of Open Access Journals (Sweden)

    Catherine M Stein

    Full Text Available Tuberculosis (TB, caused by Mycobacterium tuberculosis (Mtb, is an enduring public health problem globally, particularly in sub-Saharan Africa. Several studies have suggested a role for host genetic susceptibility in increased risk for TB but results across studies have been equivocal. As part of a household contact study of Mtb infection and disease in Kampala, Uganda, we have taken a unique approach to the study of genetic susceptibility to TB, by studying three phenotypes. First, we analyzed culture confirmed TB disease compared to latent Mtb infection (LTBI or lack of Mtb infection. Second, we analyzed resistance to Mtb infection in the face of continuous exposure, defined by a persistently negative tuberculin skin test (PTST-; this outcome was contrasted to LTBI. Third, we analyzed an intermediate phenotype, tumor necrosis factor-alpha (TNFalpha expression in response to soluble Mtb ligands enriched with molecules secreted from Mtb (culture filtrate. We conducted a full microsatellite genome scan, using genotypes generated by the Center for Medical Genetics at Marshfield. Multipoint model-free linkage analysis was conducted using an extension of the Haseman-Elston regression model that includes half sibling pairs, and HIV status was included as a covariate in the model. The analysis included 803 individuals from 193 pedigrees, comprising 258 full sibling pairs and 175 half sibling pairs. Suggestive linkage (p<10(-3 was observed on chromosomes 2q21-2q24 and 5p13-5q22 for PTST-, and on chromosome 7p22-7p21 for TB; these findings for PTST- are novel and the chromosome 7 region contains the IL6 gene. In addition, we replicated recent linkage findings on chromosome 20q13 for TB (p = 0.002. We also observed linkage at the nominal alpha = 0.05 threshold to a number of promising candidate genes, SLC11A1 (PTST- p = 0.02, IL-1 complex (TB p = 0.01, IL12BR2 (TNFalpha p = 0.006, IL12A (TB p = 0.02 and IFNGR2 (TNFalpha p = 0.002. These results confirm

  1. D Model of AL Zubarah Fortress in Qatar - Terrestrial Laser Scanning VS. Dense Image Matching

    Science.gov (United States)

    Kersten, T.; Mechelke, K.; Maziull, L.

    2015-02-01

    In September 2011 the fortress Al Zubarah, built in 1938 as a typical Arabic fortress and restored in 1987 as a museum, was recorded by the HafenCity University Hamburg using terrestrial laser scanning with the IMAGER 5006h and digital photogrammetry for the Qatar Museum Authority within the framework of the Qatar Islamic Archaeology and Heritage Project. One goal of the object recording was to provide detailed 2D/3D documentation of the fortress. This was used to complete specific detailed restoration work in the recent years. From the registered laser scanning point clouds several cuttings and 2D plans were generated as well as a 3D surface model by triangle meshing. Additionally, point clouds and surface models were automatically generated from digital imagery from a Nikon D70 using the open-source software Bundler/PMVS2, free software VisualSFM, Autodesk Web Service 123D Catch beta, and low-cost software Agisoft PhotoScan. These outputs were compared with the results from terrestrial laser scanning. The point clouds and surface models derived from imagery could not achieve the same quality of geometrical accuracy as laser scanning (i.e. 1-2 cm).

  2. Optimal image resolution for digital storage of radiotherapy-planning images

    International Nuclear Information System (INIS)

    Baba, Yuji; Furusawa, Mitsuhiro; Murakami, Ryuji; Baba, Takashi; Yokoyama, Toshimi; Nishimura, Ryuichi; Takahashi, Mutsumasa

    1998-01-01

    Purpose: To evaluate the quality of digitized radiation-planning images at different resolution and to determine the optimal resolution for digital storage. Methods and Materials: Twenty-five planning films were scanned and digitized using a film scanner at a resolution of 72 dots per inch (dpi) with 8-bit depth. The resolution of scanned images was reduced to 48, 36, 24, and 18 dpi using computer software. Image qualities of these five images (72, 48, 36, 24, and 18 dpi) were evaluated and given scores (4 = excellent; 3 = good; 2 = fair; and 1 = poor) by three radiation oncologists. An image data compression algorithm by the Joint Photographic Experts Group (JPEG) (not reversible and some information will be lost) was also evaluated. Results: The scores of digitized images with 72, 48, 36, 24, and 17 dpi resolution were 3.8 ± 0.3, 3.5 ± 0.3, 3.3 ± 0.5, 2.7 ± 0.5, and 1.6 ± 0.3, respectively. The quality of 36-dpi images were definitely worse compared to 72-dpi images, but were good enough as planning films. Digitized planning images with 72- and 36-dpi resolution requires about 800 and 200 KBytes, respectively. The JPEG compression algorithm produces little degradation in 36-dpi images at compression ratios of 5:1. Conclusion: The quality of digitized images with 36-dpi resolution was good enough as radiation-planning images and required 200 KBytes/image

  3. Enhancer Identification through Comparative Genomics

    Energy Technology Data Exchange (ETDEWEB)

    Visel, Axel; Bristow, James; Pennacchio, Len A.

    2006-10-01

    With the availability of genomic sequence from numerousvertebrates, a paradigm shift has occurred in the identification ofdistant-acting gene regulatory elements. In contrast to traditionalgene-centric studies in which investigators randomly scanned genomicfragments that flank genes of interest in functional assays, the modernapproach begins electronically with publicly available comparativesequence datasets that provide investigators with prioritized lists ofputative functional sequences based on their evolutionary conservation.However, although a large number of tools and resources are nowavailable, application of comparative genomic approaches remains far fromtrivial. In particular, it requires users to dynamically consider thespecies and methods for comparison depending on the specific biologicalquestion under investigation. While there is currently no single generalrule to this end, it is clear that when applied appropriately,comparative genomic approaches exponentially increase our power ingenerating biological hypotheses for subsequent experimentaltesting.

  4. Genome-wide scans for delineation of candidate genes regulating seed-protein content in chickpea

    Directory of Open Access Journals (Sweden)

    Hari Deo eUpadhyaya

    2016-03-01

    Full Text Available Identification of potential genes/alleles governing complex seed-protein content (SPC trait is essential in marker-assisted breeding for quality trait improvement of chickpea. Henceforth, the present study utilized an integrated genomics-assisted breeding strategy encompassing trait association analysis, selective genotyping in traditional bi-parental mapping population and differential expression profiling for the first-time to understand the complex genetic architecture of quantitative SPC trait in chickpea. For GWAS (genome-wide association study, high-throughput genotyping information of 16376 genome-based SNPs (single nucleotide polymorphism discovered from a structured population of 336 sequenced desi and kabuli accessions [with 150-200 kb LD (linkage disequilibrium decay] was utilized. This led to identification of seven most effective genomic loci (genes associated [10 to 20% with 41% combined PVE (phenotypic variation explained] with SPC trait in chickpea. Regardless of the diverse desi and kabuli genetic backgrounds, a comparable level of association potential of the identified seven genomic loci with SPC trait was observed. Five SPC-associated genes were validated successfully in parental accessions and homozygous individuals of an intra-specific desi RIL (recombinant inbred line mapping population (ICC 12299 x ICC 4958 by selective genotyping. The seed-specific expression, including differential up-regulation (> 4-fold of six SPC-associated genes particularly in accessions, parents and homozygous individuals of the aforementioned mapping population with high level of contrasting seed-protein content (21-22% was evident. Collectively, the integrated genomic approach delineated diverse naturally occurring novel functional SNP allelic variants in six potential candidate genes regulating SPC trait in chickpea. Of these, a non-synonymous SNP allele-carrying zinc finger transcription factor gene exhibiting strong association with SPC trait

  5. Three-dimensional imaging and scanning: Current and future applications for pathology

    Directory of Open Access Journals (Sweden)

    Navid Farahani

    2017-01-01

    Full Text Available Imaging is vital for the assessment of physiologic and phenotypic details. In the past, biomedical imaging was heavily reliant on analog, low-throughput methods, which would produce two-dimensional images. However, newer, digital, and high-throughput three-dimensional (3D imaging methods, which rely on computer vision and computer graphics, are transforming the way biomedical professionals practice. 3D imaging has been useful in diagnostic, prognostic, and therapeutic decision-making for the medical and biomedical professions. Herein, we summarize current imaging methods that enable optimal 3D histopathologic reconstruction: Scanning, 3D scanning, and whole slide imaging. Briefly mentioned are emerging platforms, which combine robotics, sectioning, and imaging in their pursuit to digitize and automate the entire microscopy workflow. Finally, both current and emerging 3D imaging methods are discussed in relation to current and future applications within the context of pathology.

  6. Parasitism drives host genome evolution: Insights from the Pasteuria ramosa-Daphnia magna system.

    Science.gov (United States)

    Bourgeois, Yann; Roulin, Anne C; Müller, Kristina; Ebert, Dieter

    2017-04-01

    Because parasitism is thought to play a major role in shaping host genomes, it has been predicted that genomic regions associated with resistance to parasites should stand out in genome scans, revealing signals of selection above the genomic background. To test whether parasitism is indeed such a major factor in host evolution and to better understand host-parasite interaction at the molecular level, we studied genome-wide polymorphisms in 97 genotypes of the planktonic crustacean Daphnia magna originating from three localities across Europe. Daphnia magna is known to coevolve with the bacterial pathogen Pasteuria ramosa for which host genotypes (clonal lines) are either resistant or susceptible. Using association mapping, we identified two genomic regions involved in resistance to P. ramosa, one of which was already known from a previous QTL analysis. We then performed a naïve genome scan to test for signatures of positive selection and found that the two regions identified with the association mapping further stood out as outliers. Several other regions with evidence for selection were also found, but no link between these regions and phenotypic variation could be established. Our results are consistent with the hypothesis that parasitism is driving host genome evolution. © 2017 The Author(s). Evolution © 2017 The Society for the Study of Evolution.

  7. Dose profile study in head CT scans using radiochromic films

    International Nuclear Information System (INIS)

    Ladino G, A. M.; Prata M, A.

    2016-10-01

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  8. Dose profile study in head CT scans using radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Ladino G, A. M.; Prata M, A., E-mail: amlgphys@gmail.com [Universidade Federal de Minas Gerais, Departamento de Engenharia Nuclear, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2016-10-15

    Diagnostic images of computed tomography generate higher doses than other methods of diagnostic radiology using X-ray beam attenuation. Clinical applications of CT have been increased by technological advances, what leads to a wide variety of scanner in the Brazilian technological pool. It has been difficult to implement dose reduction strategies because of the lack of proper guidance on computed tomography examinations. However, CT scanners allow adjusting acquisition parameter according to the patients physical profile and diagnostic application for which the scan is intended. The knowledge of the dose distribution is important because changes in image acquisition parameters may provide dose reduction. In this study, it was used a cylindrical head phantom in PMMA with 5 openings, what allows dose measurement in 5 regions. In a GE CT scanner, Discovery model of 64 channels, the central slice of the head phantom was irradiated and the absorbed doses were measured using a pencil ionization chamber. Radiochromic film strips were placed in the peripheral and in the central region of the head phantom and was performed a scan of 10 cm in the phantom central region. The scan was performed using the head scanning protocol of the radiobiology service, with a voltage of 120 kV. After scanning, the radiochromic film strips were digitalized and their digital images were used to have the dose longitudinal profiles. The dose values recorded have variation in a range of 18.66 to 23.57 mGy. In the results it was compared the dose index values obtained by the pencil chamber measurement to the dose longitudinal profiles recorded by the film strips. (Author)

  9. A genome-wide scan for common alleles affecting risk for autism.

    LENUS (Irish Health Repository)

    Anney, Richard

    2010-10-15

    Although autism spectrum disorders (ASDs) have a substantial genetic basis, most of the known genetic risk has been traced to rare variants, principally copy number variants (CNVs). To identify common risk variation, the Autism Genome Project (AGP) Consortium genotyped 1558 rigorously defined ASD families for 1 million single-nucleotide polymorphisms (SNPs) and analyzed these SNP genotypes for association with ASD. In one of four primary association analyses, the association signal for marker rs4141463, located within MACROD2, crossed the genome-wide association significance threshold of P < 5 × 10(-8). When a smaller replication sample was analyzed, the risk allele at rs4141463 was again over-transmitted; yet, consistent with the winner\\'s curse, its effect size in the replication sample was much smaller; and, for the combined samples, the association signal barely fell below the P < 5 × 10(-8) threshold. Exploratory analyses of phenotypic subtypes yielded no significant associations after correction for multiple testing. They did, however, yield strong signals within several genes, KIAA0564, PLD5, POU6F2, ST8SIA2 and TAF1C.

  10. A genome-wide scan for common alleles affecting risk for autism.

    Science.gov (United States)

    Anney, Richard; Klei, Lambertus; Pinto, Dalila; Regan, Regina; Conroy, Judith; Magalhaes, Tiago R; Correia, Catarina; Abrahams, Brett S; Sykes, Nuala; Pagnamenta, Alistair T; Almeida, Joana; Bacchelli, Elena; Bailey, Anthony J; Baird, Gillian; Battaglia, Agatino; Berney, Tom; Bolshakova, Nadia; Bölte, Sven; Bolton, Patrick F; Bourgeron, Thomas; Brennan, Sean; Brian, Jessica; Carson, Andrew R; Casallo, Guillermo; Casey, Jillian; Chu, Su H; Cochrane, Lynne; Corsello, Christina; Crawford, Emily L; Crossett, Andrew; Dawson, Geraldine; de Jonge, Maretha; Delorme, Richard; Drmic, Irene; Duketis, Eftichia; Duque, Frederico; Estes, Annette; Farrar, Penny; Fernandez, Bridget A; Folstein, Susan E; Fombonne, Eric; Freitag, Christine M; Gilbert, John; Gillberg, Christopher; Glessner, Joseph T; Goldberg, Jeremy; Green, Jonathan; Guter, Stephen J; Hakonarson, Hakon; Heron, Elizabeth A; Hill, Matthew; Holt, Richard; Howe, Jennifer L; Hughes, Gillian; Hus, Vanessa; Igliozzi, Roberta; Kim, Cecilia; Klauck, Sabine M; Kolevzon, Alexander; Korvatska, Olena; Kustanovich, Vlad; Lajonchere, Clara M; Lamb, Janine A; Laskawiec, Magdalena; Leboyer, Marion; Le Couteur, Ann; Leventhal, Bennett L; Lionel, Anath C; Liu, Xiao-Qing; Lord, Catherine; Lotspeich, Linda; Lund, Sabata C; Maestrini, Elena; Mahoney, William; Mantoulan, Carine; Marshall, Christian R; McConachie, Helen; McDougle, Christopher J; McGrath, Jane; McMahon, William M; Melhem, Nadine M; Merikangas, Alison; Migita, Ohsuke; Minshew, Nancy J; Mirza, Ghazala K; Munson, Jeff; Nelson, Stanley F; Noakes, Carolyn; Noor, Abdul; Nygren, Gudrun; Oliveira, Guiomar; Papanikolaou, Katerina; Parr, Jeremy R; Parrini, Barbara; Paton, Tara; Pickles, Andrew; Piven, Joseph; Posey, David J; Poustka, Annemarie; Poustka, Fritz; Prasad, Aparna; Ragoussis, Jiannis; Renshaw, Katy; Rickaby, Jessica; Roberts, Wendy; Roeder, Kathryn; Roge, Bernadette; Rutter, Michael L; Bierut, Laura J; Rice, John P; Salt, Jeff; Sansom, Katherine; Sato, Daisuke; Segurado, Ricardo; Senman, Lili; Shah, Naisha; Sheffield, Val C; Soorya, Latha; Sousa, Inês; Stoppioni, Vera; Strawbridge, Christina; Tancredi, Raffaella; Tansey, Katherine; Thiruvahindrapduram, Bhooma; Thompson, Ann P; Thomson, Susanne; Tryfon, Ana; Tsiantis, John; Van Engeland, Herman; Vincent, John B; Volkmar, Fred; Wallace, Simon; Wang, Kai; Wang, Zhouzhi; Wassink, Thomas H; Wing, Kirsty; Wittemeyer, Kerstin; Wood, Shawn; Yaspan, Brian L; Zurawiecki, Danielle; Zwaigenbaum, Lonnie; Betancur, Catalina; Buxbaum, Joseph D; Cantor, Rita M; Cook, Edwin H; Coon, Hilary; Cuccaro, Michael L; Gallagher, Louise; Geschwind, Daniel H; Gill, Michael; Haines, Jonathan L; Miller, Judith; Monaco, Anthony P; Nurnberger, John I; Paterson, Andrew D; Pericak-Vance, Margaret A; Schellenberg, Gerard D; Scherer, Stephen W; Sutcliffe, James S; Szatmari, Peter; Vicente, Astrid M; Vieland, Veronica J; Wijsman, Ellen M; Devlin, Bernie; Ennis, Sean; Hallmayer, Joachim

    2010-10-15

    Although autism spectrum disorders (ASDs) have a substantial genetic basis, most of the known genetic risk has been traced to rare variants, principally copy number variants (CNVs). To identify common risk variation, the Autism Genome Project (AGP) Consortium genotyped 1558 rigorously defined ASD families for 1 million single-nucleotide polymorphisms (SNPs) and analyzed these SNP genotypes for association with ASD. In one of four primary association analyses, the association signal for marker rs4141463, located within MACROD2, crossed the genome-wide association significance threshold of P < 5 × 10(-8). When a smaller replication sample was analyzed, the risk allele at rs4141463 was again over-transmitted; yet, consistent with the winner's curse, its effect size in the replication sample was much smaller; and, for the combined samples, the association signal barely fell below the P < 5 × 10(-8) threshold. Exploratory analyses of phenotypic subtypes yielded no significant associations after correction for multiple testing. They did, however, yield strong signals within several genes, KIAA0564, PLD5, POU6F2, ST8SIA2 and TAF1C.

  11. Full 3-dimensional digital workflow for multicomponent dental appliances A proof of concept

    NARCIS (Netherlands)

    Meer, van der Joerd; Vissink, Arjan; Ren, Yijin

    Background. The authors used a 3-dimensional (3D) printer and a bending robot to produce a multicomponent dental appliance to assess whether 3D digital models of the dentition are applicable for a full digital workflow. Methods. The authors scanned a volunteer's dentition with an intraoral scanner

  12. The Squiggle: A Digital Musical Instrument

    OpenAIRE

    Sheehan, Brian

    2004-01-01

    This paper discusses some of the issues pertaining to thedesign of digital musical instruments that are to effectively fillthe role of traditional instruments (i.e. those based on physicalsound production mechanisms). The design andimplementation of a musical instrument that addresses some ofthese issues, using scanned synthesis coupled to a "smart"physical system, is described.

  13. Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs

    International Nuclear Information System (INIS)

    Nelson, Geoff; Fahrig, Rebecca; Yoon, Sungwon; Krishna, Ganesh; Wilfley, Brian

    2013-01-01

    Purpose: An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geometry of the system requires trade-offs between patient dose, imaging field of view (FOV), and tomographic angle.Methods: Tomosynthetic angle as a function of tumor-to-detector distance was calculated. Monte Carlo Software (PCXMC) was used to calculate organ doses and effective dose for source-to-detector distances (SDDs) from 90 to 150 cm, patient locations with the tumor at 20 cm from the source to 20 cm from the detector, and FOVs centered on left lung and right lung as well as medial and distal peripheries of the lungs. These calculations were done for two systems, a SBDX system and a GE OEC-9800 C-arm fluoroscopic unit. To evaluate the dose effect of the system geometry, results from PCXMC were calculated using a scan of 300 mAs for both SBDX and fluoroscopy. The Rose Criterion was used to find the fluence required for a tumor SNR of 5, factoring in scatter, air-gap, system geometry, and patient position for all models generated with PCXMC. Using the calculated fluence for constant tumor SNR, the results from PCXMC were used to compare the patient dose for a given SNR between SBDX and fluoroscopy.Results: Tomographic angle changes with SDD only in the region near the detector. Due to their geometry, the source array and detector have a peak tomographic angle for any given SDD at a source to tumor distance that is 69.7% of the SDD assuming constant source and detector size. Changing the patient location in order to increase tomographic angle has a significant effect on organ dose distribution due to geometrical considerations. With SBDX and fluoroscopy geometries, the dose to organs typically changes in an opposing manner with changing patient

  14. Patient dose simulations for scanning-beam digital x-ray tomosynthesis of the lungs

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Geoff; Fahrig, Rebecca [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Yoon, Sungwon [Varian Medical Systems, Palo Alto, California 94304 (United States); Krishna, Ganesh [Palo Alto Medical Foundation, Mountain View, California 94040 (United States); Wilfley, Brian [Triple Ring Technologies, Inc., Newark, California 94560 (United States)

    2013-11-15

    Purpose: An improved method of image guidance for lung tumor biopsies could help reduce the high rate of false negatives. The aim of this work is to optimize the geometry of the scanning-beam digital tomography system (SBDX) for providing real-time 3D tomographic reconstructions for target verification. The unique geometry of the system requires trade-offs between patient dose, imaging field of view (FOV), and tomographic angle.Methods: Tomosynthetic angle as a function of tumor-to-detector distance was calculated. Monte Carlo Software (PCXMC) was used to calculate organ doses and effective dose for source-to-detector distances (SDDs) from 90 to 150 cm, patient locations with the tumor at 20 cm from the source to 20 cm from the detector, and FOVs centered on left lung and right lung as well as medial and distal peripheries of the lungs. These calculations were done for two systems, a SBDX system and a GE OEC-9800 C-arm fluoroscopic unit. To evaluate the dose effect of the system geometry, results from PCXMC were calculated using a scan of 300 mAs for both SBDX and fluoroscopy. The Rose Criterion was used to find the fluence required for a tumor SNR of 5, factoring in scatter, air-gap, system geometry, and patient position for all models generated with PCXMC. Using the calculated fluence for constant tumor SNR, the results from PCXMC were used to compare the patient dose for a given SNR between SBDX and fluoroscopy.Results: Tomographic angle changes with SDD only in the region near the detector. Due to their geometry, the source array and detector have a peak tomographic angle for any given SDD at a source to tumor distance that is 69.7% of the SDD assuming constant source and detector size. Changing the patient location in order to increase tomographic angle has a significant effect on organ dose distribution due to geometrical considerations. With SBDX and fluoroscopy geometries, the dose to organs typically changes in an opposing manner with changing patient

  15. Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

    Science.gov (United States)

    Rhee, Ye-Kyu

    2015-01-01

    PURPOSE The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (Pimpression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P.05). PMID:26816576

  16. Ultrafast photon counting applied to resonant scanning STED microscopy.

    Science.gov (United States)

    Wu, Xundong; Toro, Ligia; Stefani, Enrico; Wu, Yong

    2015-01-01

    To take full advantage of fast resonant scanning in super-resolution stimulated emission depletion (STED) microscopy, we have developed an ultrafast photon counting system based on a multigiga sample per second analogue-to-digital conversion chip that delivers an unprecedented 450 MHz pixel clock (2.2 ns pixel dwell time in each scan). The system achieves a large field of view (∼50 × 50 μm) with fast scanning that reduces photobleaching, and advances the time-gated continuous wave STED technology to the usage of resonant scanning with hardware-based time-gating. The assembled system provides superb signal-to-noise ratio and highly linear quantification of light that result in superior image quality. Also, the system design allows great flexibility in processing photon signals to further improve the dynamic range. In conclusion, we have constructed a frontier photon counting image acquisition system with ultrafast readout rate, excellent counting linearity, and with the capacity of realizing resonant-scanning continuous wave STED microscopy with online time-gated detection. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  17. Detecting Genomic Signatures of Natural Selection with Principal Component Analysis: Application to the 1000 Genomes Data.

    Science.gov (United States)

    Duforet-Frebourg, Nicolas; Luu, Keurcien; Laval, Guillaume; Bazin, Eric; Blum, Michael G B

    2016-04-01

    To characterize natural selection, various analytical methods for detecting candidate genomic regions have been developed. We propose to perform genome-wide scans of natural selection using principal component analysis (PCA). We show that the common FST index of genetic differentiation between populations can be viewed as the proportion of variance explained by the principal components. Considering the correlations between genetic variants and each principal component provides a conceptual framework to detect genetic variants involved in local adaptation without any prior definition of populations. To validate the PCA-based approach, we consider the 1000 Genomes data (phase 1) considering 850 individuals coming from Africa, Asia, and Europe. The number of genetic variants is of the order of 36 millions obtained with a low-coverage sequencing depth (3×). The correlations between genetic variation and each principal component provide well-known targets for positive selection (EDAR, SLC24A5, SLC45A2, DARC), and also new candidate genes (APPBPP2, TP1A1, RTTN, KCNMA, MYO5C) and noncoding RNAs. In addition to identifying genes involved in biological adaptation, we identify two biological pathways involved in polygenic adaptation that are related to the innate immune system (beta defensins) and to lipid metabolism (fatty acid omega oxidation). An additional analysis of European data shows that a genome scan based on PCA retrieves classical examples of local adaptation even when there are no well-defined populations. PCA-based statistics, implemented in the PCAdapt R package and the PCAdapt fast open-source software, retrieve well-known signals of human adaptation, which is encouraging for future whole-genome sequencing project, especially when defining populations is difficult. © The Author(s) 2015. Published by Oxford University Press on behalf of the Society for Molecular Biology and Evolution.

  18. Tomographic scanning apparatus with ionization detector means

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus using a fan beam and digital output signal. Particular reference is made to the gas-pressurized ionization detector chamber, consisting of an array of side-by-side elongate ionization detection cells, the principal axis of each of the said cells being oriented along a radius extending towards the radiation source, and connection means for applying potentials across the cells for taking their output signals. (U.K.)

  19. Calibration-free quantitative surface topography reconstruction in scanning electron microscopy

    NARCIS (Netherlands)

    Faber, E.T.; Martinez-Martinez, D.; Mansilla, C.; Ocelik, V.; De Hosson, J. Th. M.

    This work presents a new approach to obtain reliable surface topography reconstructions from 2D Scanning Electron Microscopy (SEM) images. In this method a set of images taken at different tilt angles are compared by means of digital image correlation (DlC). It is argued that the strength of the

  20. Digital Beamforming Scatterometer

    Science.gov (United States)

    Rincon, Rafael F.; Vega, Manuel; Kman, Luko; Buenfil, Manuel; Geist, Alessandro; Hillard, Larry; Racette, Paul

    2009-01-01

    feeds for vertical and horizontal polarization. System upgrades to dual polarization are currently under way. The DBSAR processor is a reconfigurable data acquisition and processor system capable of real-time, high-speed data processing. DBSAR uses an FPGA-based architecture to implement digitally down-conversion, in-phase and quadrature (I/Q) demodulation, and subsequent radar specific algorithms. The core of the processor board consists of an analog-to-digital (AID) section, three Altera Stratix field programmable gate arrays (FPGAs), an ARM microcontroller, several memory devices, and an Ethernet interface. The processor also interfaces with a navigation board consisting of a GPS and a MEMS gyro. The processor has been configured to operate in scatterometer, Synthetic Aperture Radar (SAR), and altimeter modes. All the modes are based on digital beamforming which is a digital process that generates the far-field beam patterns at various scan angles from voltages sampled in the antenna array. This technique allows steering the received beam and controlling its beam-width and side-lobe. Several beamforming techniques can be implemented each characterized by unique strengths and weaknesses, and each applicable to different measurement scenarios. In Scatterometer mode, the radar is capable to.generate a wide beam or scan a narrow beam on transmit, and to steer the received beam on processing while controlling its beamwidth and side-lobe level. Table I lists some important radar characteristics

  1. A questionnaire on the use of digital denture impressions in a preclinical setting.

    Science.gov (United States)

    Wegner, Kerstin; Michel, Karin; Seelbach, Paul Henryk; Wöstmann, Bernd

    Since February 2010, intraoral scanning (Lava COS system, 3M ESPE, Seefeld, Germany) has been integrated into the preclinical curriculum at the Department of Prosthodontics of the Justus Liebig University. All students were given a lecture and were trained using a guided scan exercise. After preparing three teeth (mandibular first premolars and mandibular first molar in the 4th quadrant) for cast crowns, the students were asked to scan the maxillary and mandibular teeth. Their acceptance of the new module, "Scanning," was analyzed with the use of a questionnaire (n = 108). The evaluation showed that 63.9% of the students perceived the digital impression to be informative, and had an overall positive opinion of this new digital technology. Concerning the difficulty of the scanning process, approximately 60.2% considered it to be manageable, while 55.6% reported that the magnified view of their preparations improved their understanding of preparing chamfer finish lines. Altogether, the majority of students appreciated this intraoral scanning device as an enhancement of their education. They indicated that this method contributes to a better understanding of crown preparations. In conclusion, the implementation of intraoral scanning seems promising in preclinical education and will be continued in the curriculum.

  2. Design of a laser scanner for a digital mammography system.

    Science.gov (United States)

    Rowlands, J A; Taylor, J E

    1996-05-01

    We have developed a digital readout system for radiographic images using a scanning laser beam. In this system, electrostatic charge images on amorphous selenium (alpha-Se) plates are read out using photo-induced discharge (PID). We discuss the design requirements of a laser scanner for the PID system and describe its construction from commercially available components. The principles demonstrated can be adapted to a variety of digital imaging systems.

  3. Genomic scan reveals loci under altitude adaptation in Tibetan and Dahe pigs.

    Directory of Open Access Journals (Sweden)

    Kunzhe Dong

    Full Text Available High altitude environments are of particular interest in the studies of local adaptation as well as their implications in physiology and clinical medicine in human. Some Chinese pig breeds, such as Tibetan pig (TBP that is well adapted to the high altitude and Dahe pig (DHP that dwells at the moderate altitude, provide ideal materials to study local adaptation to altitudes. Yet, it is still short of in-depth analysis and understanding of the genetic adaptation to high altitude in the two pig populations. In this study we conducted a genomic scan for selective sweeps using FST to identify genes showing evidence of local adaptations in TBP and DHP, with Wuzhishan pig (WZSP as the low-altitude reference. Totally, we identified 12 specific selective genes (CCBE1, F2RL1, AGGF1, ZFPM2, IL2, FGF5, PLA2G4A, ADAMTS9, NRBF2, JMJD1C, VEGFC and ADAM19 for TBP and six (OGG1, FOXM, FLT3, RTEL1, CRELD1 and RHOG for DHP. In addition, six selective genes (VPS13A, GNA14, GDAP1, PARP8, FGF10 and ADAMTS16 were shared by the two pig breeds. Among these selective genes, three (VEGFC, FGF10 and ADAMTS9 were previously reported to be linked to the local adaptation to high altitudes in pigs, while many others were newly identified by this study. Further bioinformatics analysis demonstrated that majority of these selective signatures have some biological functions relevant to the altitude adaptation, for examples, response to hypoxia, development of blood vessels, DNA repair and several hematological involvements. These results suggest that the local adaptation to high altitude environments is sophisticated, involving numerous genes and multiple biological processes, and the shared selective signatures by the two pig breeds may provide an effective avenue to identify the common adaptive mechanisms to different altitudes.

  4. Pulmonary scanning: quantitative evaluation of pulmonary arterial flow

    Energy Technology Data Exchange (ETDEWEB)

    Papaleo Netto, M; Fujioka, T [Sao Paulo Univ. (Brazil). Faculdade de Medicina; Dias Neto, A; Carvalho, N [Sao Paulo Univ. (Brazil). Centro de Medicina Nuclear

    1974-01-01

    From ten normal subjects of both sexes, the quantitative regional blood flow of the pulmonary artery was evaluated using scanning with macroaggregated radio-iodinated (/sup 131/I) albumin. It was possible to conclude that: the digital recording of data (counts/cm/sup 2/), from any particular area of interest, is the best method for this evaluation; the lung, even being a thick organ, can be well studied by quantitative scanning, since its structure doesn't hinder the passage of radiations because it is covered only by the thoracic wall; scanning can be used to evaluate regional perfusion of the pulmonary artery, based on the proportionality between density of aggregates and blood flux in the different areas; the concentration of macroaggregates on the lung's superior section never reaches more than 40% of the radioactivity of the whole lung; there is no significant difference between left and right lungs, concerning the relationship between radioactivity on the superior section and the total area and quantitative analysis of pulmonary artery flow by means of scanning is a possible, reliable, and safe technique, without distress for the patient.

  5. Pulmonary scanning: quantitative evaluation of pulmonary arterial flow

    International Nuclear Information System (INIS)

    Papaleo Netto, M.; Fujioka, T.; Dias Neto, A.; Carvalho, N.

    1974-01-01

    From ten normal subjects of both sexes, the quantitative regional blood flow of the pulmonary artery was evaluated using scanning with macroaggregated radio-iodinated ( 131 I) albumin. It was possible to conclude that: the digital recording of data (counts/cm 2 ), from any particular area of interest, is the best method for this evaluation; the lung, even being a thick organ, can be well studied by quantitative scanning, since its structure doesn't hinder the passage of radiations because it is covered only by the thoracic wall; scanning can be used to evaluate regional perfusion of the pulmonary artery, based on the proportionality between density of aggregates and blood flux in the different areas; the concentration of macroaggregates on the lung's superior section never reaches more than 40% of the radioactivity of the whole lung; there is no significant difference between left and right lungs, concerning the relationship between radioactivity on the superior section and the total area and quantitative analysis of pulmonary artery flow by means of scanning is a possible, reliable and safe technique, without distress for the patient [pt

  6. Digital radiography is promising in industrial testing

    International Nuclear Information System (INIS)

    Del Fabbro, F.

    2015-01-01

    Digital radiography has recently entered the industrial world as a tool for non-destructive testing. There are 3 types of digital radiography: computed radiography (CR), direct radiography (DR) and computed tomography (CT). In computed radiography, traditional silver-halide films are replaced by photostimulable phosphor imaging plates that are activated through laser scanning and digitized. Direct radiography uses a flat panel detector (FPD) composed of X-ray detectors that performs an immediate digital conversion of the image that can be read by a computer. DR is a perfect tool for industrial testing but the fragility of the FPD panels reduces its uses. Computed tomography is based on the principle of DR to get data corresponding to successive cross-section images of the object. These data are processed by a software to get a 3-dimensional image of the object. CT was first developed for medical use but requires some improvement to become more accurate, faster, particularly for big objects. In recent years DR has enjoyed the highest growth rate in digital radiography. (A.C.)

  7. Optimization Of Scan Range For 3d Point Localization In Statscan Digital Medical Radiology

    Directory of Open Access Journals (Sweden)

    Jacinta S. Kimuyu

    2015-08-01

    Full Text Available The emergence of computerized medical imaging in early 1970s which merged with digital technology in the 1980s was celebrated as a major breakthrough in three-dimensional 3D medicine. However a recent South African innovation the high speed scanning Lodox Statscan Critical Digital Radiology modality posed challenges in X-ray photogrammetry due to the systems intricate imaging geometry. The study explored the suitability of the Direct Linear Transformation as a method for the determination of 3D coordinates of targeted points from multiple images acquired with the Statscan X-ray system and optimization of the scan range. This investigation was carried out as a first step towards the development of a method to determine the accurate positions of points on or inside the human body. The major causes of errors in three-dimensional point localization using Statscan images were firstly the X-ray beam divergence and secondly the position of the point targets above the X-ray platform. The experiments carried out with two reference frames showed that point positions could be established with RMS values in the mm range in the middle axis of the X-ray patient platform. This range of acceptable mm accuracies extends about 15 to 20 cm sideways towards the edge of the X-ray table and to about 20 cm above the table surface. Beyond this range accuracy deteriorated significantly reaching RMS values of 30mm to 40 mm. The experiments further showed that the inclusion of control points close to the table edges and more than 20 cm above the table resulted in lower accuracies for the L - parameters of the DLT solution than those derived from points close to the center axis only. As the accuracy of the L - parameters propagates into accuracy of the final coordinates of newly determined points it is essential to restrict the space of the control points to the above described limits. If one adopts the usual approach of surrounding the object by known control points then

  8. Hypertextuality in the Alexander von Humboldt Digital Library

    Directory of Open Access Journals (Sweden)

    Detlev Doherr

    2016-04-01

    Full Text Available To do justice to the legacy of Alexander von Humboldt, a 19th century German scientist and explorer an information and knowledge management system is required to preserve the author's original intent and promote an awareness of all his relevant works. Although all of Humboldt's works can be found on the internet as digitized papers, the complexity and internal interconnectivity of the writings is not very transparent. Humboldt's concepts of interaction cannot be adequately represented only by digitized papers or scanned documents. The Humboldt Portal is an attempt to create a new generation of digital libraries, providing a new form of interaction and synthesis between humanistic texts and scientific observation. The digital version of his documents supplies dynamic links to sources, maps, images, graphs and relevant texts in accordance with his visions, because "everything is interconnectedness".

  9. Genome-wide linkage analysis for human longevity

    DEFF Research Database (Denmark)

    Beekman, Marian; Blanché, Hélène; Perola, Markus

    2013-01-01

    Clear evidence exists for heritability of human longevity, and much interest is focused on identifying genes associated with longer lives. To identify such longevity alleles, we performed the largest genome-wide linkage scan thus far reported. Linkage analyses included 2118 nonagenarian Caucasian...

  10. Copy Number Variations in Tilapia Genomes.

    Science.gov (United States)

    Li, Bi Jun; Li, Hong Lian; Meng, Zining; Zhang, Yong; Lin, Haoran; Yue, Gen Hua; Xia, Jun Hong

    2017-02-01

    Discovering the nature and pattern of genome variation is fundamental in understanding phenotypic diversity among populations. Although several millions of single nucleotide polymorphisms (SNPs) have been discovered in tilapia, the genome-wide characterization of larger structural variants, such as copy number variation (CNV) regions has not been carried out yet. We conducted a genome-wide scan for CNVs in 47 individuals from three tilapia populations. Based on 254 Gb of high-quality paired-end sequencing reads, we identified 4642 distinct high-confidence CNVs. These CNVs account for 1.9% (12.411 Mb) of the used Nile tilapia reference genome. A total of 1100 predicted CNVs were found overlapping with exon regions of protein genes. Further association analysis based on linear model regression found 85 CNVs ranging between 300 and 27,000 base pairs significantly associated to population types (R 2  > 0.9 and P > 0.001). Our study sheds first insights on genome-wide CNVs in tilapia. These CNVs among and within tilapia populations may have functional effects on phenotypes and specific adaptation to particular environments.

  11. A genome-wide scan for common alleles affecting risk for autism

    Science.gov (United States)

    Anney, Richard; Klei, Lambertus; Pinto, Dalila; Regan, Regina; Conroy, Judith; Magalhaes, Tiago R.; Correia, Catarina; Abrahams, Brett S.; Sykes, Nuala; Pagnamenta, Alistair T.; Almeida, Joana; Bacchelli, Elena; Bailey, Anthony J.; Baird, Gillian; Battaglia, Agatino; Berney, Tom; Bolshakova, Nadia; Bölte, Sven; Bolton, Patrick F.; Bourgeron, Thomas; Brennan, Sean; Brian, Jessica; Carson, Andrew R.; Casallo, Guillermo; Casey, Jillian; Chu, Su H.; Cochrane, Lynne; Corsello, Christina; Crawford, Emily L.; Crossett, Andrew; Dawson, Geraldine; de Jonge, Maretha; Delorme, Richard; Drmic, Irene; Duketis, Eftichia; Duque, Frederico; Estes, Annette; Farrar, Penny; Fernandez, Bridget A.; Folstein, Susan E.; Fombonne, Eric; Freitag, Christine M.; Gilbert, John; Gillberg, Christopher; Glessner, Joseph T.; Goldberg, Jeremy; Green, Jonathan; Guter, Stephen J.; Hakonarson, Hakon; Heron, Elizabeth A.; Hill, Matthew; Holt, Richard; Howe, Jennifer L.; Hughes, Gillian; Hus, Vanessa; Igliozzi, Roberta; Kim, Cecilia; Klauck, Sabine M.; Kolevzon, Alexander; Korvatska, Olena; Kustanovich, Vlad; Lajonchere, Clara M.; Lamb, Janine A.; Laskawiec, Magdalena; Leboyer, Marion; Le Couteur, Ann; Leventhal, Bennett L.; Lionel, Anath C.; Liu, Xiao-Qing; Lord, Catherine; Lotspeich, Linda; Lund, Sabata C.; Maestrini, Elena; Mahoney, William; Mantoulan, Carine; Marshall, Christian R.; McConachie, Helen; McDougle, Christopher J.; McGrath, Jane; McMahon, William M.; Melhem, Nadine M.; Merikangas, Alison; Migita, Ohsuke; Minshew, Nancy J.; Mirza, Ghazala K.; Munson, Jeff; Nelson, Stanley F.; Noakes, Carolyn; Noor, Abdul; Nygren, Gudrun; Oliveira, Guiomar; Papanikolaou, Katerina; Parr, Jeremy R.; Parrini, Barbara; Paton, Tara; Pickles, Andrew; Piven, Joseph; Posey, David J; Poustka, Annemarie; Poustka, Fritz; Prasad, Aparna; Ragoussis, Jiannis; Renshaw, Katy; Rickaby, Jessica; Roberts, Wendy; Roeder, Kathryn; Roge, Bernadette; Rutter, Michael L.; Bierut, Laura J.; Rice, John P.; Salt, Jeff; Sansom, Katherine; Sato, Daisuke; Segurado, Ricardo; Senman, Lili; Shah, Naisha; Sheffield, Val C.; Soorya, Latha; Sousa, Inês; Stoppioni, Vera; Strawbridge, Christina; Tancredi, Raffaella; Tansey, Katherine; Thiruvahindrapduram, Bhooma; Thompson, Ann P.; Thomson, Susanne; Tryfon, Ana; Tsiantis, John; Van Engeland, Herman; Vincent, John B.; Volkmar, Fred; Wallace, Simon; Wang, Kai; Wang, Zhouzhi; Wassink, Thomas H.; Wing, Kirsty; Wittemeyer, Kerstin; Wood, Shawn; Yaspan, Brian L.; Zurawiecki, Danielle; Zwaigenbaum, Lonnie; Betancur, Catalina; Buxbaum, Joseph D.; Cantor, Rita M.; Cook, Edwin H.; Coon, Hilary; Cuccaro, Michael L.; Gallagher, Louise; Geschwind, Daniel H.; Gill, Michael; Haines, Jonathan L.; Miller, Judith; Monaco, Anthony P.; Nurnberger, John I.; Paterson, Andrew D.; Pericak-Vance, Margaret A.; Schellenberg, Gerard D.; Scherer, Stephen W.; Sutcliffe, James S.; Szatmari, Peter; Vicente, Astrid M.; Vieland, Veronica J.; Wijsman, Ellen M.; Devlin, Bernie; Ennis, Sean; Hallmayer, Joachim

    2010-01-01

    Although autism spectrum disorders (ASDs) have a substantial genetic basis, most of the known genetic risk has been traced to rare variants, principally copy number variants (CNVs). To identify common risk variation, the Autism Genome Project (AGP) Consortium genotyped 1558 rigorously defined ASD families for 1 million single-nucleotide polymorphisms (SNPs) and analyzed these SNP genotypes for association with ASD. In one of four primary association analyses, the association signal for marker rs4141463, located within MACROD2, crossed the genome-wide association significance threshold of P < 5 × 10−8. When a smaller replication sample was analyzed, the risk allele at rs4141463 was again over-transmitted; yet, consistent with the winner's curse, its effect size in the replication sample was much smaller; and, for the combined samples, the association signal barely fell below the P < 5 × 10−8 threshold. Exploratory analyses of phenotypic subtypes yielded no significant associations after correction for multiple testing. They did, however, yield strong signals within several genes, KIAA0564, PLD5, POU6F2, ST8SIA2 and TAF1C. PMID:20663923

  12. Accuracy assessment of high frequency 3D ultrasound for digital impression-taking of prepared teeth

    Science.gov (United States)

    Heger, Stefan; Vollborn, Thorsten; Tinschert, Joachim; Wolfart, Stefan; Radermacher, Klaus

    2013-03-01

    Silicone based impression-taking of prepared teeth followed by plaster casting is well-established but potentially less reliable, error-prone and inefficient, particularly in combination with emerging techniques like computer aided design and manufacturing (CAD/CAM) of dental prosthesis. Intra-oral optical scanners for digital impression-taking have been introduced but until now some drawbacks still exist. Because optical waves can hardly penetrate liquids or soft-tissues, sub-gingival preparations still need to be uncovered invasively prior to scanning. High frequency ultrasound (HFUS) based micro-scanning has been recently investigated as an alternative to optical intra-oral scanning. Ultrasound is less sensitive against oral fluids and in principal able to penetrate gingiva without invasively exposing of sub-gingival preparations. Nevertheless, spatial resolution as well as digitization accuracy of an ultrasound based micro-scanning system remains a critical parameter because the ultrasound wavelength in water-like media such as gingiva is typically smaller than that of optical waves. In this contribution, the in-vitro accuracy of ultrasound based micro-scanning for tooth geometry reconstruction is being investigated and compared to its extra-oral optical counterpart. In order to increase the spatial resolution of the system, 2nd harmonic frequencies from a mechanically driven focused single element transducer were separated and corresponding 3D surface models were calculated for both fundamentals and 2nd harmonics. Measurements on phantoms, model teeth and human teeth were carried out for evaluation of spatial resolution and surface detection accuracy. Comparison of optical and ultrasound digital impression taking indicate that, in terms of accuracy, ultrasound based tooth digitization can be an alternative for optical impression-taking.

  13. Application of Intra-Oral Dental Scanners in the Digital Workflow of Implantology

    Science.gov (United States)

    van der Meer, Wicher J.; Andriessen, Frank S.; Wismeijer, Daniel; Ren, Yijin

    2012-01-01

    Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. Materials and methods: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned with three intra-oral scanners: the CEREC (Sirona), the iTero (Cadent) and the Lava COS (3M). In software the digital files were imported and the distance between the centres of the cylinders and the angulation between the cylinders was assessed. These values were compared to the measurements made on a high accuracy 3D scan of the master model. Results: The distance errors were the smallest and most consistent for the Lava COS. The distance errors for the Cerec were the largest and least consistent. All the angulation errors were small. Conclusions: The Lava COS in combination with a high accuracy scanning protocol resulted in the smallest and most consistent errors of all three scanners tested when considering mean distance errors in full arch impressions both in absolute values and in consistency for both measured distances. For the mean angulation errors, the Lava COS had the smallest errors between cylinders 1–2 and the largest errors between cylinders 1–3, although the absolute difference with the smallest mean value (iTero) was very small (0,0529°). An expected increase in distance and/or angular errors over the length of the arch due to an accumulation of registration errors of the patched 3D surfaces could be observed in this study design, but the effects were statistically not significant. Clinical relevance For making impressions of implant cases for digital workflows, the most accurate scanner with the scanning protocol that will ensure the most accurate digital impression should be used. In our study model that was the Lava COS with the high accuracy scanning protocol. PMID:22937030

  14. Saving HEBBLE Data from Oblivion: From Faded Paper Copy to Digital Files

    Science.gov (United States)

    Mishonov, A. V.; Richardson, M. J.; Gardner, W. D.

    2017-12-01

    The high-energy benthic boundary-layer experiment (HEBBLE) was designed to test the hypothesis that bed modifications can result from contemporary local erosion and deposition. We observed several 'benthic storms' that resuspended record-high concentrations of particulate matter - filtered samples up to 12,700 µg/l. High kinetic energy and near-bed flow were associated with these record-high concentrations of particulate matter at 4,9600 m off the Nova Scotian Rise in the north-west Atlantic, showing that large episodic events resuspend bottom sediments in deep ocean areas. As part of HEBBLE, CTD/Transmissometer data were collected in the late 1970's and early 1980's, including more than 40 stations on cruise KN74. Although many papers were published based on HEBBLE data, no electronic copies of the KN74 CTD/Transmissometer data were preserved. Because of the uniqueness of the record-high particulate matter concentrations, with ambient current velocities of >70 cm/sec near the seafloor, it was important to rescue these data. We had a paper printout of all of the digital CTD data. Attempts to scan and apply OCR to the data proved futile with standard copying/scanning machines. Texas A&M University Library Digital Service Center scanned our copies with a SupraScanQuartzA00-CamQuartzHD scanner and used ABBYY Fine Reader for OCR and PDF, more frequently used in the humanities for digital preservation and conservation. Their scans were markedly better, but still contained many errors because of poor quality originals. Two students were hired to QA/QC the hundreds of pages of data. While tedious, they successfully corrected the data, thus making it possible to make maps and sections shown here and submit data to publicly accessible archives for future generations to use. These data reside in the OAKTrust Digital Repository at Texas A&M University. After final QA/QC these data will be submitted to NCEI and will be merged with World Ocean Database (WOD).

  15. Better Visualisation of Air-borne Laser Scanning for geomorphological and archaeological interpretation

    DEFF Research Database (Denmark)

    Ljungberg, Thomas; Scott, D; Kristiansen, Søren Munch

    Digital elevation models derived from high-precision Air-borne Laser Scanning (ALS or LiDAR) point clouds are becoming increasingly available throughout the world. These elevation models presents a very valuable tool for locating and interpreting geomorphological as well as archaeological features...

  16. Design and verification of the miniature optical system for small object surface profile fast scanning

    Science.gov (United States)

    Chi, Sheng; Lee, Shu-Sheng; Huang, Jen, Jen-Yu; Lai, Ti-Yu; Jan, Chia-Ming; Hu, Po-Chi

    2016-04-01

    As the progress of optical technologies, different commercial 3D surface contour scanners are on the market nowadays. Most of them are used for reconstructing the surface profile of mold or mechanical objects which are larger than 50 mm×50 mm× 50 mm, and the scanning system size is about 300 mm×300 mm×100 mm. There are seldom optical systems commercialized for surface profile fast scanning for small object size less than 10 mm×10 mm×10 mm. Therefore, a miniature optical system has been designed and developed in this research work for this purpose. Since the most used scanning method of such system is line scan technology, we have developed pseudo-phase shifting digital projection technology by adopting projecting fringes and phase reconstruction method. A projector was used to project a digital fringe patterns on the object, and the fringes intensity images of the reference plane and of the sample object were recorded by a CMOS camera. The phase difference between the plane and object can be calculated from the fringes images, and the surface profile of the object was reconstructed by using the phase differences. The traditional phase shifting method was accomplished by using PZT actuator or precisely controlled motor to adjust the light source or grating and this is one of the limitations for high speed scanning. Compared with the traditional optical setup, we utilized a micro projector to project the digital fringe patterns on the sample. This diminished the phase shifting processing time and the controlled phase differences between the shifted phases become more precise. Besides, the optical path design based on a portable device scanning system was used to minimize the size and reduce the number of the system components. A screwdriver section about 7mm×5mm×5mm has been scanned and its surface profile was successfully restored. The experimental results showed that the measurement area of our system can be smaller than 10mm×10mm, the precision reached to

  17. Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis.

    Directory of Open Access Journals (Sweden)

    Fan Zhang

    Full Text Available Dental measurements have been commonly taken from plaster dental models obtained from alginate impressions can. Through the use of an intraoral scanner, digital impressions now acquire the information directly from the mouth. The purpose of this study was to determine the validity of the intraoral scans compared to plaster models.Two types of dental models (intraoral scan and plaster model of 20 subjects were included in this study. The subjects had impressions taken of their teeth and made as plaster model. In addition, their mouths were scanned with the intraoral scanner and the scans were converted into digital models. Eight transverse and 16 anteroposterior measurements, 24 tooth heights and widths were recorded on the plaster models with a digital caliper and on the intraoral scan with 3D reverse engineering software. For 3D surface analysis, the two models were superimposed by using best-fit algorithm. The average differences between the two models at all points on the surfaces were computed. Paired t-test and Bland-Altman plot were used to determine the validity of measurements from the intraoral scan compared to those from the plaster model.There were no significant differences between the plaster models and intraoral scans, except for one measurement of lower intermolar width. The Bland-Altman plots of all measurements showed that differences between the two models were within the limits of agreement. The average surface difference between the two models was within 0.10 mm.The results of the present study indicate that the intraoral scans are clinically acceptable for diagnosis and treatment planning in dentistry and can be used in place of plaster models.

  18. Validity of Intraoral Scans Compared with Plaster Models: An In-Vivo Comparison of Dental Measurements and 3D Surface Analysis

    Science.gov (United States)

    2016-01-01

    Purpose Dental measurements have been commonly taken from plaster dental models obtained from alginate impressions can. Through the use of an intraoral scanner, digital impressions now acquire the information directly from the mouth. The purpose of this study was to determine the validity of the intraoral scans compared to plaster models. Materials and Methods Two types of dental models (intraoral scan and plaster model) of 20 subjects were included in this study. The subjects had impressions taken of their teeth and made as plaster model. In addition, their mouths were scanned with the intraoral scanner and the scans were converted into digital models. Eight transverse and 16 anteroposterior measurements, 24 tooth heights and widths were recorded on the plaster models with a digital caliper and on the intraoral scan with 3D reverse engineering software. For 3D surface analysis, the two models were superimposed by using best-fit algorithm. The average differences between the two models at all points on the surfaces were computed. Paired t-test and Bland-Altman plot were used to determine the validity of measurements from the intraoral scan compared to those from the plaster model. Results There were no significant differences between the plaster models and intraoral scans, except for one measurement of lower intermolar width. The Bland-Altman plots of all measurements showed that differences between the two models were within the limits of agreement. The average surface difference between the two models was within 0.10 mm. Conclusions The results of the present study indicate that the intraoral scans are clinically acceptable for diagnosis and treatment planning in dentistry and can be used in place of plaster models. PMID:27304976

  19. Comparative investigations of high resolution scanning systems for digitising X-ray films

    International Nuclear Information System (INIS)

    Wessel, H.; Rose, P.

    1992-01-01

    The visual or computer-aided evaluation of digitised X-ray films in non-destructive material testing requires highly sensitive scanning systems. They must be able to resolve differences in blackening and convert them into digital data without loss, if possible. Only in this way is the detection of the finest cracks in weld seams or contraction in areas of great sudden changes in blackening of cast parts guaranteed. In the context of this work, measurements were carried out which describe the reproduction properties of different scanning systems. After a short explanation of the different scanning systems, the results of the measurements are shown and evaluated. (orig.) [de

  20. SARS CTL vaccine candidates; HLA supertype-, genome-wide scanning and biochemical validation

    DEFF Research Database (Denmark)

    Sylvester-Hvid, C.; Nielsen, Morten; Lamberth, K.

    2004-01-01

    . Exact knowledge of how the immune system handles protein antigens would allow for the identification of such linear sequences directly, from genomic/proteomic sequence information (Lauemoller et al., Rev Immunogenet 2001: 2: 477-91). The latter was recently established when a causative coronavirus (SARS...

  1. Assessing the Accuracy of High Resolution Digital Surface Models Computed by PhotoScan® and MicMac® in Sub-Optimal Survey Conditions

    Directory of Open Access Journals (Sweden)

    Marion Jaud

    2016-06-01

    Full Text Available For monitoring purposes and in the context of geomorphological research, Unmanned Aerial Vehicles (UAV appear to be a promising solution to provide multi-temporal Digital Surface Models (DSMs and orthophotographs. There are a variety of photogrammetric software tools available for UAV-based data. The objective of this study is to investigate the level of accuracy that can be achieved using two of these software tools: Agisoft PhotoScan® Pro and an open-source alternative, IGN© MicMac®, in sub-optimal survey conditions (rugged terrain, with a large variety of morphological features covering a range of roughness sizes, poor GPS reception. A set of UAV images has been taken by a hexacopter drone above the Rivière des Remparts, a river on Reunion Island. This site was chosen for its challenging survey conditions: the topography of the study area (i involved constraints on the flight plan; (ii implied errors on some GPS measurements; (iii prevented an optimal distribution of the Ground Control Points (GCPs and; (iv was very complex to reconstruct. Several image processing tests are performed with different scenarios in order to analyze the sensitivity of each software package to different parameters (image quality, numbers of GCPs, etc.. When computing the horizontal and vertical errors within a control region on a set of ground reference targets, both methods provide rather similar results. A precision up to 3–4 cm is achievable with these software packages. The DSM quality is also assessed over the entire study area comparing PhotoScan DSM and MicMac DSM with a Terrestrial Laser Scanner (TLS point cloud. PhotoScan and MicMac DSM are also compared at the scale of particular features. Both software packages provide satisfying results: PhotoScan is more straightforward to use but its source code is not open; MicMac is recommended for experimented users as it is more flexible.

  2. X-ray film digitization using a personal computer and hand-held scanner: a simple technique for storing images

    International Nuclear Information System (INIS)

    Munoz-Nunez, C. F.; Lloret-Alcaniz, A.

    1998-01-01

    To develop a simple, low-cost technique for the digitization of X-ray films for personal use. A 66-MHz 486 PC with 8 MB of RAM, a Logitech ScanMan 256 hand-held scanner and a standard negatoscope with the power source converted to direct current. Although the system was originally designed for the digitization of mammographies, it has also been used with computed tomography, magnetic resonance, digital angiography and ultrasonographic images, as well as plain X-rays. After a minimal training period, the system digitized X-ray films easily and rapidly. Although the scanning values vary depending on the type of image to be digitized, an input spatial resolution of 200 dpi and a contrast resolution of 256 levels of gray are generally adequate. Of the storage formats tested, JPEG presented the best quality/image size ratio. A simple, low-cost technique has been developed for the digitization of X-ray films. This technique enables the storage of images in a digital format, thus facilitating their presentation and transmission. (Author) 9 refs

  3. Categorisation of full waveform data provided by laser scanning devices

    Science.gov (United States)

    Ullrich, Andreas; Pfennigbauer, Martin

    2011-11-01

    In 2004, a laser scanner device for commercial airborne laser scanning applications, the RIEGL LMS-Q560, was introduced to the market, making use of a radical alternative approach to the traditional analogue signal detection and processing schemes found in LIDAR instruments so far: digitizing the echo signals received by the instrument for every laser pulse and analysing these echo signals off-line in a so-called full waveform analysis in order to retrieve almost all information contained in the echo signal using transparent algorithms adaptable to specific applications. In the field of laser scanning the somewhat unspecific term "full waveform data" has since been established. We attempt a categorisation of the different types of the full waveform data found in the market. We discuss the challenges in echo digitization and waveform analysis from an instrument designer's point of view and we will address the benefits to be gained by using this technique, especially with respect to the so-called multi-target capability of pulsed time-of-flight LIDAR instruments.

  4. Broad scan linkage analysis in a large Tourette family pedigree

    Energy Technology Data Exchange (ETDEWEB)

    Peiffer, A.; Leppert, M. [Univ. of Utah Health Sciences Center, Salt Lake City, UT (United States); Wetering, B.J.M. van der [Univ. Hospital Rotterdam (Netherlands)

    1994-09-01

    Attempts to find a gene causing Tourette syndrome (TS) using linkage analysis have been unsuccessful even though as much as 65% of the autosomal genetic map has been excluded by the pooled results from several laboratories collaborating worldwide. One reason for this failure may be the misclassification of affection status of marry-in spouses. Specifically, we have found that six unrelated spouses in our Utah TS pedigree suffer from TS, obsessive-compulsive disorder or chronic motor tics. In light of these findings we decided to conduct a complete genomic scan from this Utah kindred with polymorphic markers in three related sibships in which there was no assortative mating. A linkage study assuming autosomal dominant inheritance was done using tetranucleotide repeat markers developed at the University of Utah. We selected markers that were less than 300 bp in size and that gave a heterozygosity of over 70% upon analysis in 4 CEPH families. Results to date with 95 markers run at an interval of 30 cM (covering 61% of the genome) show no evidence of linkage. We intend to extend the coverage to 100% of the genome. Pending completion of this scan, failure to provide evidence of linkage in our TS pedigree might then be attributed to phenotypic misclassification or erroneous assumptions regarding the genetic model of transmission.

  5. Cardiovascular Precision Medicine in the Genomics Era

    Directory of Open Access Journals (Sweden)

    Alexandra M. Dainis, BS

    2018-04-01

    Full Text Available Summary: Precision medicine strives to delineate disease using multiple data sources—from genomics to digital health metrics—in order to be more precise and accurate in our diagnoses, definitions, and treatments of disease subtypes. By defining disease at a deeper level, we can treat patients based on an understanding of the molecular underpinnings of their presentations, rather than grouping patients into broad categories with one-size-fits-all treatments. In this review, the authors examine how precision medicine, specifically that surrounding genetic testing and genetic therapeutics, has begun to make strides in both common and rare cardiovascular diseases in the clinic and the laboratory, and how these advances are beginning to enable us to more effectively define risk, diagnose disease, and deliver therapeutics for each individual patient. Key Words: genome sequencing, genomics, precision medicine, targeted therapeutics

  6. A smartphone photogrammetry method for digitizing prosthetic socket interiors.

    Science.gov (United States)

    Hernandez, Amaia; Lemaire, Edward

    2017-04-01

    Prosthetic CAD/CAM systems require accurate 3D limb models; however, difficulties arise when working from the person's socket since current 3D scanners have difficulties scanning socket interiors. While dedicated scanners exist, they are expensive and the cost may be prohibitive for a limited number of scans per year. A low-cost and accessible photogrammetry method for socket interior digitization is proposed, using a smartphone camera and cloud-based photogrammetry services. 15 two-dimensional images of the socket's interior are captured using a smartphone camera. A 3D model is generated using cloud-based software. Linear measurements were comparing between sockets and the related 3D models. 3D reconstruction accuracy averaged 2.6 ± 2.0 mm and 0.086 ± 0.078 L, which was less accurate than models obtained by high quality 3D scanners. However, this method would provide a viable 3D digital socket reproduction that is accessible and low-cost, after processing in prosthetic CAD software. Clinical relevance The described method provides a low-cost and accessible means to digitize a socket interior for use in prosthetic CAD/CAM systems, employing a smartphone camera and cloud-based photogrammetry software.

  7. Programmable Digital Controller

    Science.gov (United States)

    Wassick, Gregory J.

    2012-01-01

    An existing three-channel analog servo loop controller has been redesigned for piezoelectric-transducer-based (PZT-based) etalon control applications to a digital servo loop controller. This change offers several improvements over the previous analog controller, including software control over proportional-integral-derivative (PID) parameters, inclusion of other data of interest such as temperature and pressure in the control laws, improved ability to compensate for PZT hysteresis and mechanical mount fluctuations, ability to provide pre-programmed scanning and stepping routines, improved user interface, expanded data acquisition, and reduced size, weight, and power.

  8. Genome-wide Identification and Expression Analysis of Half-size ABCG Genes in Malus × domestica

    Directory of Open Access Journals (Sweden)

    Juanjuan MA

    2018-03-01

    Full Text Available Half-size adenosine triphosphate-binding cassette transporter subgroup G (ABCG genes play crucial roles in regulating the movements of a variety of substrates and have been well studied in several plants. However, half-size ABCGs have not been characterized in detail in apple (Malus × domestica Borkh.. Here, we performed a genome-wide identification and expression analysis of the half-size ABCG gene family in apple. A total of 46 apple half-size ABCGs were identified and divided into six clusters according to the phylogenetic analysis. A gene structural analysis showed that most half-size ABCGs in the same cluster shared a similar exon–intron organization. A gene duplication analysis showed that segmental, tandem and whole-genome duplications could account for the expansion of half-size ABCG transporters in M. domestica. Moreover, a promoter scan, digital expression analysis and RNA-seq revealed that MdABCG21 may be involved in root's cytokinin transport and that ABCG17 may be involved in the lateral bud development of M. spectabilis ‘Bly114’ by mediating cytokinin transport. The data presented here lay the foundation for further investigations into the biological and physiological processes and functions of half-size ABCG genes in apple. Keywords: apple, ABCG gene, duplication, gene expression

  9. Computer-aided design and manufacture of hyrax devices: Can we really go digital?

    Science.gov (United States)

    Graf, Simon; Cornelis, Marie A; Hauber Gameiro, Gustavo; Cattaneo, Paolo M

    2017-12-01

    The aim of this pilot study was to illustrate the feasibility of a new digital procedure to fabricate metallic orthodontic appliances. Hyrax appliances for rapid palatal expansion were produced for 3 patients using a CAD/CAM procedure without physical impressions or printed models. The work flow consisted of intraoral scanning, digital design with incorporation of a scanned prefabricated expansion screw, direct 3-dimensional metal printing via laser melting, welding of an expansion screw, insertion, and finally activation in the patients' mouths. Finite element analyses of the actual hyrax appliances were performed to ensure that the printable material used in combination with the chosen design would withstand the stress generated during activation. The results of these analyses were positive. The clinical results showed that this procedure is an efficient and viable digital way for constructing metallic orthodontic appliances. The flexibility of the digital appliance design, together with the biocompatibility and strength of the chosen material, offers a huge potential for more advanced appliance design. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  10. Control and monitoring of doses to patients in a team of digital mammography

    International Nuclear Information System (INIS)

    Agulla Otero, M.; Torres Cabrera, R.; Hernando Gonzalez, I.

    2013-01-01

    In recent years is widespread use of imaging devices digital mammography. One of the advantages associated with this scanning is the ability to access a large amount of information contained in the headwaters of own digital images. The exploitation of this information allows the calculation of doses received by patients. This paper describes the methodology employed for this purpose and are presented the results of the control and monitoring of doses given in a digital mammography equipment. (Author)

  11. Toward a physical map of the genome of the nematode Caenorhabditis elegans

    International Nuclear Information System (INIS)

    Coulson, A.; Sulston, J.; Brenner, S.; Karn, J.

    1986-01-01

    A technique for digital characterization and comparison of DNA fragments, using restriction enzymes, is described. The technique is being applied to fragments from the nematode Caenorhabditis elegans (i) to facilitate cross-indexing of clones emanating from different laboratories and (ii) to construct a physical map of the genome. Eight hundred sixty clusters of clones, from 35 to 350 kilobases long and totaling about 60% of the genome, have been characterized

  12. Digital analysis of air photography for sustainable forest management; Digital flygbildsteknik foer uthaallig skogsskoetsel

    Energy Technology Data Exchange (ETDEWEB)

    Ekstrand, Sam; Loefmark, Magnus; Johansson, Desiree

    2001-02-01

    The objective of this project was to develop methods for estimation of forest stand variables using digital analysis of near infrared air photography. Near Infrared air photography covering an area 200 km northwest of Stockholm was scanned and ortho rectified. Methods for digital classification, normalisation of view angle effects and estimation of parameters such as timber volume, stand density, crown coverage, species composition, defoliation and number of dead or dying trees have been developed. Major results were that the functions for normalisation on view angle effects on tree size as viewed from the focal point strongly improved the stand estimates. Timber volume, stand density, species composition as well as the ecological variables were estimated with accuracies comparable to those of subjective field inventory methods. In spite of the photography being of high quality, differences in colour between flight lines gave problems with separation of pine and spruce. This may be solved using post-classification manual editing, but will cause an increase in costs. In the future, digital cameras or calibration lamps within the photograph could further reduce this problem.

  13. Scanning and georeferencing historical USGS quadrangles

    Science.gov (United States)

    Fishburn, Kristin A.; Davis, Larry R.; Allord, Gregory J.

    2017-06-23

    The U.S. Geological Survey (USGS) National Geospatial Program is scanning published USGS 1:250,000-scale and larger topographic maps printed between 1884, the inception of the topographic mapping program, and 2006. The goal of this project, which began publishing the Historical Topographic Map Collection in 2011, is to provide access to a digital repository of USGS topographic maps that is available to the public at no cost. For more than 125 years, USGS topographic maps have accurately portrayed the complex geography of the Nation. The USGS is the Nation’s largest producer of traditional topographic maps, and, prior to 2006, USGS topographic maps were created using traditional cartographic methods and printed using a lithographic process. The next generation of topographic maps, US Topo, is being released by the USGS in digital form, and newer technologies make it possible to also deliver historical maps in the same electronic format that is more publicly accessible.

  14. Implementation of a dedicated digital projectional radiographic system in thoracic imaging

    International Nuclear Information System (INIS)

    Aberle, D.R.; Batra, P.; Hayrapetian, A.S.; Brown, K.; Morioka, C.A.; Steckel, R.J.

    1988-01-01

    An integrated digital radiographic system was evaluated with respect to image quality and impact on diagnosis relative to conventional chest radiographs for a variety of focal and diffuse lung processes. Digital images were acquired with a stimulable phosphor plate detector that was scanned by a semiconductor laser for immediate digitalization to a 2,048 X 2,464 X 10-bit image. Digital images were displayed on a 2,048-line monitor and printed on 14 X 17-inch film with use of a laser film printer (Kodak). Preliminary results with this system, including the effects of user interaction with the display monitor, inverse intensity display, and regional magnification techniques, indicate that it may be successfully implemented for thoracic imaging

  15. Accuracy of Digital vs. Conventional Implant Impressions

    Science.gov (United States)

    Lee, Sang J.; Betensky, Rebecca A.; Gianneschi, Grace E.; Gallucci, German O.

    2015-01-01

    The accuracy of digital impressions greatly influences the clinical viability in implant restorations. The aim of this study is to compare the accuracy of gypsum models acquired from the conventional implant impression to digitally milled models created from direct digitalization by three-dimensional analysis. Thirty gypsum and 30 digitally milled models impressed directly from a reference model were prepared. The models were scanned by a laboratory scanner and 30 STL datasets from each group were imported to an inspection software. The datasets were aligned to the reference dataset by a repeated best fit algorithm and 10 specified contact locations of interest were measured in mean volumetric deviations. The areas were pooled by cusps, fossae, interproximal contacts, horizontal and vertical axes of implant position and angulation. The pooled areas were statistically analysed by comparing each group to the reference model to investigate the mean volumetric deviations accounting for accuracy and standard deviations for precision. Milled models from digital impressions had comparable accuracy to gypsum models from conventional impressions. However, differences in fossae and vertical displacement of the implant position from the gypsum and digitally milled models compared to the reference model, exhibited statistical significance (p<0.001, p=0.020 respectively). PMID:24720423

  16. Trueness and precision of digital impressions obtained using an intraoral scanner with different head size in the partially edentulous mandible.

    Science.gov (United States)

    Hayama, Hironari; Fueki, Kenji; Wadachi, Juro; Wakabayashi, Noriyuki

    2018-03-01

    It remains unclear whether digital impressions obtained using an intraoral scanner are sufficiently accurate for use in fabrication of removable partial dentures. We therefore compared the trueness and precision between conventional and digital impressions in the partially edentulous mandible. Mandibular Kennedy Class I and III models with soft silicone simulated-mucosa placed on the residual edentulous ridge were used. The reference models were converted to standard triangulated language (STL) file format using an extraoral scanner. Digital impressions were obtained using an intraoral scanner with a large or small scanning head, and converted to STL files. For conventional impressions, pressure impressions of the reference models were made and working casts fabricated using modified dental stone; these were converted to STL file format using an extraoral scanner. Conversion to STL file format was performed 5 times for each method. Trueness and precision were evaluated by deviation analysis using three-dimensional image processing software. Digital impressions had superior trueness (54-108μm), but inferior precision (100-121μm) compared to conventional impressions (trueness 122-157μm, precision 52-119μm). The larger intraoral scanning head showed better trueness and precision than the smaller head, and on average required fewer scanned images of digital impressions than the smaller head (pdigital impressions. Digital impressions are partially comparable to conventional impressions in terms of accuracy; the use of a larger scanning head may improve the accuracy for removable partial denture fabrication. Copyright © 2018 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  17. Effect of length and location of edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography scans.

    Science.gov (United States)

    Jamjoom, Faris Z; Kim, Do-Gyoon; Lee, Damian J; McGlumphy, Edwin A; Yilmaz, Burak

    2018-02-05

    Effects of length and location of the edentulous area on the accuracy of prosthetic treatment plan incorporation into cone-beam computed tomography (CBCT) scans has not been investigated. To evaluate the effect of length and location of the edentulous area on the accuracy of prosthetic treatment plan incorporation into CBCT scans using different methods. Direct digital scans of a completely dentate master model with removable radiopaque teeth were made using an intraoral scanner, and digital scans of stone duplicates of the master model were made using a laboratory scanner. Specific teeth were removed to simulate different clinical situations and their CBCT scans were made. Surface scans were registered onto the CBCT scans. Radiographic templates for each clinical situation were also fabricated and used during CBCT scans of the master models. Using metrology software, three-dimensional (3D) deviation was measured on standard tesselation language (STL) files created from the CBCT scans against an STL file of the master model created from a CBCT scan. Statistical analysis was done using the MIXED procedure in a statistical software and Tukey HSD test (α =.05). The interaction between location and method was significant (P = .009). Location had no significant effect on registration methods (P > .05), but on the radiographic templates (P = .011). Length of the edentulous area did not have any significant effect (P > .05). Accuracy of digital image registration methods was similar and higher than that of radiographic templates in all clinical situations. Tooth-bound radiographic templates were significantly more accurate than the free-end templates. The results of this study suggest using image registration instead of radiographic templates when planning dental implants, particularly in free-end situations. © 2018 Wiley Periodicals, Inc.

  18. How digital revolution has an impact on maintenance

    International Nuclear Information System (INIS)

    Thevenon, J.B.

    2017-01-01

    Digital technologies can manage a huge quantity of data from a variety of sensors which draws an accurate picture of the real state of a component or even a complete plant. Combined with predictive models, the knowledge of the real state of a component can lead to predictive maintenance in which components are repaired or replaced before they fail. EDF takes the opportunity of the ten-yearly outage of a plant to draw a digital twin of this plant with the help of 3-dimensional photography and laser scans. This digital twin will be used to visualize and validate any change or maintenance operation. The digital twin will be also useful to communicate efficiently with sub-contractors and visualize the work to be done. In the future, new applications will be added to the twin and for instance the level of contamination could be implemented in order to increase safety for maintenance operations. Needless to say that a digital twin will be very useful for the dismantling of the installation. (A.C.)

  19. Multiline digital radiographic imager study with synchronization to detector gas ion drift

    International Nuclear Information System (INIS)

    Peyret, O.

    1985-01-01

    This direct digital radiographic imager is based on X-ray detection in high pressure rare gas ionization chamber. This linear multidetector, from which scanning radiography is realized, records many lines together. Spatial resolution performance in scanning direction are made sure by scanning synchronization with ion drift in detector. After a physical study and a potential evaluation of its performances on mock-up, a 128 cell prototype has been realized. The first images give validation and limits of such a radiographic process [fr

  20. Three-dimensional body scanning system for apparel mass-customization

    Science.gov (United States)

    Xu, Bugao; Huang, Yaxiong; Yu, Weiping; Chen, Tong

    2002-07-01

    Mass customization is a new manufacturing trend in which mass-market products (e.g., apparel) are quickly modified one at a time based on customers' needs. It is an effective competing strategy for maximizing customers' satisfaction and minimizing inventory costs. An automatic body measurement system is essential for apparel mass customization. This paper introduces the development of a body scanning system, body size extraction methods, and body modeling algorithms. The scanning system utilizes the multiline triangulation technique to rapidly acquire surface data on a body, and provides accurate body measurements, many of which are not available with conventional methods. Cubic B-spline curves are used to connect and smooth body curves. From the scanned data, a body form can be constructed using linear Coons surfaces. The body form can be used as a digital model of the body for 3-D garment design and for virtual try-on of a designed garment. This scanning system and its application software enable apparel manufacturers to provide custom design services to consumers seeking personal-fit garments.

  1. Ultra-high performance, solid-state, autoradiographic image digitization and analysis system

    International Nuclear Information System (INIS)

    Lear, J.L.; Pratt, J.P.; Ackermann, R.F.; Plotnick, J.; Rumley, S.

    1990-01-01

    We developed a Macintosh II-based, charge-coupled device (CCD), image digitization and analysis system for high-speed, high-resolution quantification of autoradiographic image data. A linear CCD array with 3,500 elements was attached to a precision drive assembly and mounted behind a high-uniformity lens. The drive assembly was used to sweep the array perpendicularly to its axis so that an entire 20 x 25-cm autoradiographic image-containing film could be digitized into 256 gray levels at 50-microns resolution in less than 30 sec. The scanner was interfaced to a Macintosh II computer through a specially constructed NuBus circuit board and software was developed for autoradiographic data analysis. The system was evaluated by scanning individual films multiple times, then measuring the variability of the digital data between the different scans. Image data were found to be virtually noise free. The coefficient of variation averaged less than 1%, a value significantly exceeding the accuracy of both high-speed, low-resolution, video camera (VC) systems and low-speed, high-resolution, rotating drum densitometers (RDD). Thus, the CCD scanner-Macintosh computer analysis system offers the advantage over VC systems of the ability to digitize entire films containing many autoradiograms, but with much greater speed and accuracy than achievable with RDD scanners

  2. [Diagnossis and treatment of complicated anterior teeth esthetic defects by combination of whole-process digital esthetic rehabilitation with periodontic surgery].

    Science.gov (United States)

    Li, Z; Liu, Y S; Ye, H Q; Liu, Y S; Hu, W J; Zhou, Y S

    2017-02-18

    To explore a new method of whole-process digital esthetic prosthodontic rehabilitation combined with periodontic surgery for complicated anterior teeth esthetic defects accompanied by soft tissue morphology, to provide an alternative choice for solving this problem under the guidance of three-dimensional (3D) printing digital dental model and surgical guide, thus completing periodontic surgery and digital esthetic rehabilitation of anterior teeth. In this study, 12 patients with complicated esthetic problems accompanied by soft tissue morphology in their anterior teeth were included. The dentition and facial images were obtained by intra-oral scanning and three-dimensional (3D) facial scanning and then calibrated. Two esthetic designs and prosthodontic outcome predictions were created by computer aided design /computer aided manufacturing (CAD/CAM) software combined with digital photography, including consideration of white esthetics and comprehensive consideration of pink-white esthetics. The predictive design of prostheses and the facial appearances of the two designs were evaluated by the patients. If the patients chose the design of comprehensive consideration of pink-white esthetics, they would choose whether they would receive periodontic surgery before esthetic rehabilitation. The dentition design cast of those who chose periodontic surgery would be 3D printed for the guide of periodontic surgery accordingly. In light of the two digital designs based on intra-oral scanning, facing scanning and digital photography, the satisfaction rate of the patients was significantly higher for the comprehensive consideration of pink-white esthetic design (Pesthetic rehabilitation. The 3D printed digital dental model and surgical guide provided significant instructions for periodontic surgery, and achieved success transfer from digital design to clinical application. The prostheses were fabricated by CAD/CAM, thus realizing the whole-process digital esthetic rehabilitation

  3. Longitudinal and transverse digital image reconstruction with a tomographic scanner

    International Nuclear Information System (INIS)

    Pickens, D.R.; Price, R.R.; Erickson, J.J.; Patton, J.A.; Partain, C.L.; Rollo, F.D.

    1981-01-01

    A Siemens Gammasonics PHO/CON-192 Multiplane Imager is interfaced to a digital computer for the purpose of performing tomographic reconstructions from the data collected during a single scan. Data from the two moving gamma cameras as well as camera position information are sent to the computer by an interface designed in the authors' laboratory. Backprojection reconstruction is implemented by the computer. Longitudinal images in whole-body format as well as smaller formats are reconstructed for up to six planes simultaneously from the list mode data. Transverse reconstructions are demonstrated for 201 T1 myocardial scans. Post-reconstruction deconvolution processing to remove the blur artifact (characteristic of focal plane tomography) is applied to a multiplane phantom. Digital data acquisition of data and reconstruction of images are practical, and can extend the usefulness of the machine when compared with the film output (author)

  4. Image-scanning measurement using video dissection cameras

    International Nuclear Information System (INIS)

    Carson, J.S.

    1978-01-01

    A high speed dimensional measuring system capable of scanning a thin film network, and determining if there are conductor widths, resistor widths, or spaces not typical of the design for this product is described. The eye of the system is a conventional TV camera, although such devices as image dissector cameras or solid-state scanners may be used more often in the future. The analog signal from the TV camera is digitized for processing by the computer and is presented to the TV monitor to assist the operator in monitoring the system's operation. Movable stages are required when the field of view of the scanner is less than the size of the object. A minicomputer controls the movement of the stage, and communicates with the digitizer to select picture points that are to be processed. Communications with the system are maintained through a teletype or CRT terminal

  5. Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems

    Science.gov (United States)

    Wood, Tim J.; Moore, Craig S.; Saunderson, John R.; Beavis, Andrew W.

    2018-01-01

    Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a useful metric for the optimisation of clinical imaging systems. The aim of this study was to develop a methodology for measuring eDQE and eDE on a Philips microdose mammography (MDM) L30 photon counting scanning system, and to compare performance with two conventional flat panel systems. A custom made lead-blocker was manufactured to enable the accurate determination of dose measurements, and modulation transfer functions were determined free-in-air at heights of 2, 4 and 6 cm above the breast support platform. eDQE were calculated for a Philips MDM L30, Hologic Dimensions and Siemens Inspiration digital mammography system for 2, 4 and 6 cm thick poly(methyl methacrylate) (PMMA). The beam qualities (target/filter and kilovoltage) assessed were those selected by the automatic exposure control, and anti-scatter grids were used where available. Measurements of eDQE demonstrate significant differences in performance between the slit- and scan-directions for the photon counting imaging system. MTF has been shown to be the limiting factor in the scan-direction, which results in a rapid fall in eDQE at mid-to-high spatial frequencies. A comparison with two flat panel mammography systems demonstrates that this may limit image quality for small details, such as micro-calcifications, which correlates with a more conventional image quality assessment with the CDMAM phantom. eDE has shown the scanning photon counting system offers superior performance for low spatial frequencies, which will be important for the detection of large low contrast masses. Both eDQE and eDE are proposed as useful metrics that should enable optimisation of the Philips MDM L30.

  6. The Sloan Digital Sky Survey: Status and prospects

    Energy Technology Data Exchange (ETDEWEB)

    Loveday, J.; SDSS Collaboration

    1996-05-01

    The Sloan Digital Sky Survey (SDSS) is a project to definitively map {pi} steradians of the local Universe. An array of CCD detectors used in drift-scan mode will digitally image the sky in five passbands to a limiting magnitude of r{prime} {approximately} 23. Selected from the imaging survey, 10{sup 6} galaxies and 10{sup 5} quasars will be observed spectroscopically. I describe the current status of the survey, which is due to begin observations early in 1997, and its prospects for constraining models for dark matter in the Universe. 8 refs., 7 figs.

  7. Review of P-scan computer-based ultrasonic inservice inspection system. Supplement 1

    International Nuclear Information System (INIS)

    Harris, R.V. Jr.; Angel, L.J.

    1995-12-01

    This Supplement reviews the P-scan system, a computer-based ultrasonic system used for inservice inspection of piping and other components in nuclear power plants. The Supplement was prepared using the methodology described in detail in Appendix A of NUREG/CR-5985, and is based on one month of using the system in a laboratory. This Supplement describes and characterizes: computer system, ultrasonic components, and mechanical components; scanning, detection, digitizing, imaging, data interpretation, operator interaction, data handling, and record-keeping. It includes a general description, a review checklist, and detailed results of all tests performed

  8. Comparison of digital surface displacements of maxillary dentures based on noninvasive anatomic landmarks.

    Science.gov (United States)

    Norvell, Nicholas G; Korioth, Tom V; Cagna, David R; Versluis, Antheunis

    2018-02-08

    Artificial markers called fiducials are commonly used to orient digitized surfaces for analysis. However, when these markers are tangible and placed in the region of interest, they may alter surface topography and influence data analysis. The purpose of this in vitro study was to apply a modified digital surface fitting method based on anatomic landmarks to evaluate denture accuracy and to use 2 different denture processing techniques to evaluate the method. The goal was to noninvasively measure and describe any surface differences in denture processing techniques at the intaglio and denture tooth levels. Twenty standardized maxillary complete dentures were waxed on standardized edentulous casts and processed by using acrylic resin compression (COM, n=10) and injection molding (INJ, n=10) methods. Digital scans were recorded of the anatomic surface of the cast, the intaglio and cameo surfaces of the acrylic resin dentures, and the cameo surface of the wax dentures. Three anatomic fiducials were identified on denture intaglio and cast scans and 4 on the cameo surfaces of waxed and acrylic resin denture scans. These fiducials were then used to digitally align the anatomic with the processed intaglio surfaces and the waxed with the processed cameo surfaces. Surface displacements were compared among processed dentures expressed at specific points (9 tissue landmarks and 8 tooth landmarks). The accuracy of surface displacements was assessed by changes in the number and location of anatomic fiducials. The scanning precision and the intraobserver repeatability in the selection of dental landmarks were also determined. For each landmark, the spatial (x, y, and z) mean differences between the 2 processing techniques were calculated for the intaglio and the cameo surfaces and presented on each orthogonal plane. Statistical nonparametric comparison of these means was analyzed with the Mann-Whitney U test (α=.05). Benjamini-Hochberg corrections for multiple comparisons were

  9. Scene reassembly after multimodal digitization and pipeline evaluation using photorealistic rendering

    DEFF Research Database (Denmark)

    Stets, Jonathan Dyssel; Dal Corso, Alessandro; Nielsen, Jannik Boll

    2017-01-01

    of the lighting environment. This enables pixelwise comparison of photographs of the real scene with renderings of the digital version of the scene. Such quantitative evaluation is useful for verifying acquired material appearance and reconstructed surface geometry, which is an important aspect of digital content......Transparent objects require acquisition modalities that are very different from the ones used for objects with more diffuse reflectance properties. Digitizing a scene where objects must be acquired with different modalities requires scene reassembly after reconstruction of the object surfaces....... This reassembly of a scene that was picked apart for scanning seems unexplored. We contribute with a multimodal digitization pipeline for scenes that require this step of reassembly. Our pipeline includes measurement of bidirectional reflectance distribution functions and high dynamic range imaging...

  10. Avaliação de métodos indiretos de digitalização de radiografias cefalométricas em comparação ao método digital direto Evaluation of indirect methods of digitization of cephalometric radiographs in comparison with the direct digital method

    Directory of Open Access Journals (Sweden)

    Cleomar Donizeth Rodrigues

    2010-08-01

    Full Text Available OBJETIVO: avaliar métodos de digitalização indireta de radiografias cefalométricas em comparação ao método digital direto. MÉTODOS: a amostra foi composta de dez radiografias cefalométricas adquiridas pelo Orthopantomograph OP100/Orthocef OC100 (GE - Instrumentarium, digital direto. As imagens foram inseridas no programa Adobe Photoshop® e cinco pontos cefalométricos foram marcados. Procedeu-se a impressão em transparência e foi feita a digitalização indireta das imagens impressas, por meio das câmeras fotográficas digitais Sony® DSC-W5 e Canon® Rebel XT/EOS 350D, fixas em estativa, nas distâncias de 25cm e 60cm e com o scanner Scan Jet 4C Hewlett Packard®. As imagens diretas e indiretas foram inseridas e calibradas no software Radiocef Studio (Radiomemory®, Brasil, marcando-se o centro dos pontos previamente assinalados. A análise cefalométrica computadorizada gerou três grandezas angulares e quatro lineares, as quais foram submetidas a tratamento estatístico. RESULTADOS: as imagens do scanner Scan Jet 4C HP® demonstraram pequenas alterações significativas, porém, sem relevância clínica. Quando da digitalização a 60cm da radiografia, as duas câmeras causaram distorções que foram significativas mas clinicamente aceitáveis; e, a 25cm, causaram as maiores distorções, com importância clínica, na Canon® Rebel XT. CONCLUSÃO: o scanner Scan Jet 4C HP® com leitor de transparências foi o melhor método e as câmeras operando a 60cm mostraram-se adequadas para digitalização de radiografias. As câmeras na distância de 25cm causaram distorções na imagem que alteraram as medidas lineares, podendo a Canon® Rebel XT comprometer o diagnóstico ortodôntico.OBJECTIVE: To evaluate the indirect digitization method of cephalometric radiographs in comparison with the direct digital method. METHODS: The sample was composed of ten cephalometric radiographs acquired by Orthopantomograph OP100/Orthocef OC100 (GE

  11. Digital tomosynthesis with an on-board kilovoltage imaging device

    International Nuclear Information System (INIS)

    Godfrey, Devon J.; Yin, F.-F.; Oldham, Mark; Yoo, Sua; Willett, Christopher

    2006-01-01

    Purpose: To generate on-board digital tomosynthesis (DTS) and reference DTS images for three-dimensional image-guided radiation therapy (IGRT) as an alternative to conventional portal imaging or on-board cone-beam computed tomography (CBCT). Methods and Materials: Three clinical cases (prostate, head-and-neck, and liver) were selected to illustrate the capabilities of on-board DTS for IGRT. Corresponding reference DTS images were reconstructed from digitally reconstructed radiographs computed from planning CT image sets. The effect of scan angle on DTS slice thickness was examined by computing the mutual information between coincident CBCT and DTS images, as the DTS scan angle was varied from 0 o to 165 o . A breath-hold DTS acquisition strategy was implemented to remove respiratory motion artifacts. Results: Digital tomosynthesis slices appeared similar to coincident CBCT planes and yielded substantially more anatomic information than either kilovoltage or megavoltage radiographs. Breath-hold DTS acquisition improved soft-tissue visibility by suppressing respiratory motion. Conclusions: Improved bony and soft-tissue visibility in DTS images is likely to improve target localization compared with radiographic verification techniques and might allow for daily localization of a soft-tissue target. Breath-hold DTS is a potential alternative to on-board CBCT for sites prone to respiratory motion

  12. Diagnostic Efficiency in Digital Pathology: A Comparison of Optical Versus Digital Assessment in 510 Surgical Pathology Cases.

    Science.gov (United States)

    Mills, Anne M; Gradecki, Sarah E; Horton, Bethany J; Blackwell, Rebecca; Moskaluk, Christopher A; Mandell, James W; Mills, Stacey E; Cathro, Helen P

    2018-01-01

    Prior work has shown that digital images and microscopic slides can be interpreted with comparable diagnostic accuracy. Although accuracy has been well-validated, the interpretative time for digital images has scarcely been studied and concerns about efficiency remain a major barrier to adoption. We investigated the efficiency of digital pathology when compared with glass slide interpretation in the diagnosis of surgical pathology biopsy and resection specimens. Slides were pulled from 510 surgical pathology cases from 5 organ systems (gastrointestinal, gynecologic, liver, bladder, and brain). Original diagnoses were independently confirmed by 2 validating pathologists. Diagnostic slides were scanned using the Philips IntelliSite Pathology Solution. Each case was assessed independently on digital and optical by 3 reading pathologists, with a ≥6 week washout period between modalities. Reading pathologists recorded assessment times for each modality; digital times included time to load the case. Diagnostic accuracy was determined based on whether a rendered diagnosis differed significantly from the original diagnosis. Statistical analysis was performed to assess for differences in interpretative times across modalities. All 3 reading pathologists showed comparable diagnostic accuracy across optical and digital modalities (mean major discordance rates with original diagnosis: 4.8% vs. 4.4%, respectively). Mean assessment times ranged from 1.2 to 9.1 seconds slower on digital versus optical. The slowest reader showed a significant learning effect during the course of the study so that digital assessment times decreased over time and were comparable with optical times by the end of the series. Organ site and specimen type did not significantly influence differences in interpretative times. In summary, digital image reading times compare favorably relative to glass slides across a variety of organ systems and specimen types. Mean increase in assessment time is 4

  13. Joint Calibration of 3d Laser Scanner and Digital Camera Based on Dlt Algorithm

    Science.gov (United States)

    Gao, X.; Li, M.; Xing, L.; Liu, Y.

    2018-04-01

    Design a calibration target that can be scanned by 3D laser scanner while shot by digital camera, achieving point cloud and photos of a same target. A method to joint calibrate 3D laser scanner and digital camera based on Direct Linear Transformation algorithm was proposed. This method adds a distortion model of digital camera to traditional DLT algorithm, after repeating iteration, it can solve the inner and external position element of the camera as well as the joint calibration of 3D laser scanner and digital camera. It comes to prove that this method is reliable.

  14. Digital vs. conventional implant impressions: efficiency outcomes.

    Science.gov (United States)

    Lee, Sang J; Gallucci, German O

    2013-01-01

    The aim of this pilot study was to evaluate the efficiency, difficulty and operator's preference of a digital impression compared with a conventional impression for single implant restorations. Thirty HSDM second year dental students performed conventional and digital implant impressions on a customized model presenting a single implant. The outcome of the impressions was evaluated under an acceptance criteria and the need for retake/rescan was decided. The efficiency of both impression techniques was evaluated by measuring the preparation, working, and retake/scan time (m/s) and the number of retakes/rescans. Participants' perception on the level of difficulty for the both impressions was assessed with a visual analogue scale (VAS) questionnaire. Multiple questionnaires were obtained to assess the participants' perception on preference, effectiveness and proficiency. Mean total treatment time was of 24:42 m/s for conventional and 12:29 m/s for digital impressions (P impressions (P impression (P impression technique and 30.63 (±17.57) for digital impression technique (P = 0.006). Sixty percent of the participants preferred the digital impression, 7% the conventional impression technique and 33% preferred either technique. Digital impressions resulted in a more efficient technique than conventional impressions. Longer preparation, working, and retake time were consumed to complete an acceptable conventional impression. Difficulty was lower for the digital impression compared with the conventional ones when performed by inexperienced second year dental students. © 2012 John Wiley & Sons A/S.

  15. Precision and Accuracy of a Digital Impression Scanner in Full-Arch Implant Rehabilitation.

    Science.gov (United States)

    Pesce, Paolo; Pera, Francesco; Setti, Paolo; Menini, Maria

    To evaluate the accuracy and precision of a digital scanner used to scan four implants positioned according to an immediate loading implant protocol and to assess the accuracy of an aluminum framework fabricated from a digital impression. Five master casts reproducing different edentulous maxillae with four tilted implants were used. Four scan bodies were screwed onto the low-profile abutments, and a digital intraoral scanner was used to perform five digital impressions of each master cast. To assess trueness, a metal framework of the best digital impression was produced with computer-aided design/computer-assisted manufacture (CAD/CAM) technology and passive fit was assessed with the Sheffield test. Gaps between the frameworks and the implant analogs were measured with a stereomicroscope. To assess precision, three-dimensional (3D) point cloud processing software was used to measure the deviations between the five digital impressions of each cast by producing a color map. The deviation values were grouped in three classes, and differences were assessed between class 2 (representing lower discrepancies) and the assembled classes 1 and 3 (representing the higher negative and positive discrepancies, respectively). The frameworks showed a mean gap of 3D point cloud software, with higher frequencies of points in class 2 than in grouped classes 1 and 3 (P impression may represent a reliable method for fabricating full-arch implant frameworks with good passive fit when tilted implants are present.

  16. Development of an image intensifier-TV digital imaging system with a multiple-slit scanning x-ray beam

    International Nuclear Information System (INIS)

    Kume, Y.; Doi, K.

    1986-01-01

    The authors are developing a new digital x-ray imaging system employing a multiple-slit assembly (MSA) and an image intensifier (II)-TV digital system. The final image consisting of primary radiation is digitally reconstructed from multiple slit images obtained with the MSA. This system can significantly reduce the scattered radiation from an object and the veiling glare from II-TV system. The quality of the reconstructed image is related to many parameters, such as slit width, the number of image frames, and the image reconstruction algorithm. They present the effect of these various parameters on basic imaging properties and the practicability of the method in comparison with conventional wide beam imaging

  17. Scanning fluorescent microscopy is an alternative for quantitative fluorescent cell analysis.

    Science.gov (United States)

    Varga, Viktor Sebestyén; Bocsi, József; Sipos, Ferenc; Csendes, Gábor; Tulassay, Zsolt; Molnár, Béla

    2004-07-01

    Fluorescent measurements on cells are performed today with FCM and laser scanning cytometry. The scientific community dealing with quantitative cell analysis would benefit from the development of a new digital multichannel and virtual microscopy based scanning fluorescent microscopy technology and from its evaluation on routine standardized fluorescent beads and clinical specimens. We applied a commercial motorized fluorescent microscope system. The scanning was done at 20 x (0.5 NA) magnification, on three channels (Rhodamine, FITC, Hoechst). The SFM (scanning fluorescent microscopy) software included the following features: scanning area, exposure time, and channel definition, autofocused scanning, densitometric and morphometric cellular feature determination, gating on scatterplots and frequency histograms, and preparation of galleries of the gated cells. For the calibration and standardization Immuno-Brite beads were used. With application of shading compensation, the CV of fluorescence of the beads decreased from 24.3% to 3.9%. Standard JPEG image compression until 1:150 resulted in no significant change. The change of focus influenced the CV significantly only after +/-5 microm error. SFM is a valuable method for the evaluation of fluorescently labeled cells. Copyright 2004 Wiley-Liss, Inc.

  18. Digitalized preservation and presentation of historical building - taking traditional temples and dougong as examples

    Science.gov (United States)

    Yang, W. B.; Yen, Y. N.; Cheng, H. M.

    2015-08-01

    The integration of preservation of heritage and the digital technology is an important international trend in the 21st century. The digital technology not only is able to record and preserve detailed documents and information of heritage completely, but also brings the value-added features effectively. In this study, 3D laser scanning is used to perform the digitalized archives for the interior and exterior body work of the building which contains integration of 3D scanner technology, mobile scanning collaboration and multisystem reverse modeling and integration technology. The 3D model is built by combining with multi-media presentations and reversed modeling in real scale to perform the simulation of virtual reality (VR). With interactive teaching and presentation of augmented reality to perform the interaction technology to extend the continuously update in traditional architecture information. With the upgrade of the technology and value-added in digitalization, the cultural asset value can be experienced through 3D virtual reality which makes the information presentation from the traditional reading in the past toward user operation with sensory experience and keep exploring the possibilities and development of cultural asset preservation by using digital technology makes the presentation and learning of cultural asset information toward diversification.

  19. HOVE-Wedge-Filtering of Geomorphologic Terrestrial Laser Scan Data

    Directory of Open Access Journals (Sweden)

    Helmut Panholzer

    2018-02-01

    Full Text Available Terrestrial laser scanning has become an important surveying technique in many fields such as natural hazard assessment. To analyse earth surface processes, it is useful to generate a digital terrain model originated from laser scan point cloud data. To determine the terrain surface as precisely as possible, it is often necessary to filter out points that do not represent the terrain surface. Examples are vegetation, vehicles, and animals. In mountainous terrain with a small-structured topography, filtering is very difficult. Here, automatic filtering solutions usually designed for airborne laser scan data often lead to unsatisfactory results. In this work, we further develop an existing approach for automated filtering of terrestrial laser scan data, which is based on the assumption that no other surface point can be located in the area above a direct line of sight between scanner and another measured point. By taking into account several environmental variables and a repetitive calculation method, the modified method leads to significantly better results. The root-mean-square-error (RSME for the same test measurement area could be reduced from 5.284 to 1.610. In addition, a new approach for filtering and interpolation of terrestrial laser scanning data is presented using a grid with horizontal and vertical angular data and the measurement length.

  20. THE DIGITAL VON FAHRENHEID PYRAMID

    Directory of Open Access Journals (Sweden)

    M. Bura

    2017-08-01

    Full Text Available 3D Scanners Lab from Digital Humanities Laboratory at the University of Warsaw initiated the scientific project, the purpose of which was to call attention to systematically penetrated and devastated pyramid-shaped tomb from the XVIII/XIX century, of family von Fahrenheid in Rapa in Banie Mazurskie commune (NE Poland. By conducting a series of non-invasive studies, such as 3D inventory using terrestrial laser scanning (TLS, thermal imaging, georadar measurements (around and inside the tomb and anthropological research of mummified remains as well - the complete dataset was collected. Through the integration of terrestrial (TLS and airborne laser scanning (ALS authors managed to analyse the surroundings of Fahrenheid pyriamid and influence of some objects (like trees on the condition and visibility of the Pyramids in the landscape.

  1. SU-F-T-173: One-Scan Protocol: Verifying the Delivery of Spot-Scanning Proton Beam

    Energy Technology Data Exchange (ETDEWEB)

    Chan, M; Li, J [Memorial Sloan-Kettering Cancer Center, Basking Ridge, NJ (United States); Chen, C; Mah, D [Procure Treatment Center, Somerset, NJ (United States); Tang, X [Memorial Sloan Kettering Cancer Center, West Harrison, NY (United States); Li, X [Memorial Sloan Kettering Cancer Center, Rockville Centre, NY (United States); Tang, G [Memorial Sloan Kettering Cancer Center, New York, NY (United States)

    2016-06-15

    Purpose: Radiochromic film for spot-scanning QA provides high spatial resolution and efficiency gains from one-shot irradiation for multiple depths. However, calibration can be a tedious procedure which may limit widespread use. Moreover, since there may be an energy dependence, which manifests as a depth dependence, this may require additional measurements for each patient. We present a one-scan protocol to simplify the procedure. Methods: We performed the calibration using an EBT3 film at depths of 18, 20, 24cm of Plastic Water exposed by a 6-level step-wedge plan on a Proteus Plus proton system (IBA, Belgium). The calibration doses ranged 65–250 cGy(RBE) for proton energies of 170–200MeV. A clinical prostate+nodes plan was used for validation. The planar doses at selected depths were measured with EBT3 films and analyzed using one-scan protocol (one-scan digitization of QA film and at least one film exposed to known dose). The Gamma passing rates, dose-difference maps, and profiles of 2D planar doses measured with EBT3 film, IBA MatriXX PT, versus TPS calculations were analyzed and compared. Results: The EBT3 film measurement results matched well with the TPS calculation data with an average passing rate of ∼95% for 2%/2mm and slightly lower passing rates were obtained from an ion chamber array detector. We were able to demonstrate that the use of a proton step-wedge provided clinically acceptable results and minimized variations between film-scanner orientation, inter-scan, and scanning conditions. Furthermore, it could be derived from no more than two films exposed to known doses (one could be zero) for rescaling the master calibration curve at each depth. Conclusion: The use of a proton step-wedge for calibration of EBT3 film increases efficiency. The sensitivity of the calibration to depth variations has been explored. One-scan protocol results appear to be comparable to that of the ion chamber array detector. One author has a research grant from

  2. Genome-wide association scan in HIV-1-infected individuals identifying variants influencing disease course.

    Directory of Open Access Journals (Sweden)

    Daniëlle van Manen

    Full Text Available BACKGROUND: AIDS develops typically after 7-11 years of untreated HIV-1 infection, with extremes of very rapid disease progression (15 years. To reveal additional host genetic factors that may impact on the clinical course of HIV-1 infection, we designed a genome-wide association study (GWAS in 404 participants of the Amsterdam Cohort Studies on HIV-1 infection and AIDS. METHODS: The association of SNP genotypes with the clinical course of HIV-1 infection was tested in Cox regression survival analyses using AIDS-diagnosis and AIDS-related death as endpoints. RESULTS: Multiple, not previously identified SNPs, were identified to be strongly associated with disease progression after HIV-1 infection, albeit not genome-wide significant. However, three independent SNPs in the top ten associations between SNP genotypes and time between seroconversion and AIDS-diagnosis, and one from the top ten associations between SNP genotypes and time between seroconversion and AIDS-related death, had P-values smaller than 0.05 in the French Genomics of Resistance to Immunodeficiency Virus cohort on disease progression. CONCLUSIONS: Our study emphasizes that the use of different phenotypes in GWAS may be useful to unravel the full spectrum of host genetic factors that may be associated with the clinical course of HIV-1 infection.

  3. Genome-Wide Association Scan in HIV-1-Infected Individuals Identifying Variants Influencing Disease Course

    Science.gov (United States)

    van Manen, Daniëlle; Delaneau, Olivier; Kootstra, Neeltje A.; Boeser-Nunnink, Brigitte D.; Limou, Sophie; Bol, Sebastiaan M.; Burger, Judith A.; Zwinderman, Aeilko H.; Moerland, Perry D.; van 't Slot, Ruben; Zagury, Jean-François; van 't Wout, Angélique B.; Schuitemaker, Hanneke

    2011-01-01

    Background AIDS develops typically after 7–11 years of untreated HIV-1 infection, with extremes of very rapid disease progression (15 years). To reveal additional host genetic factors that may impact on the clinical course of HIV-1 infection, we designed a genome-wide association study (GWAS) in 404 participants of the Amsterdam Cohort Studies on HIV-1 infection and AIDS. Methods The association of SNP genotypes with the clinical course of HIV-1 infection was tested in Cox regression survival analyses using AIDS-diagnosis and AIDS-related death as endpoints. Results Multiple, not previously identified SNPs, were identified to be strongly associated with disease progression after HIV-1 infection, albeit not genome-wide significant. However, three independent SNPs in the top ten associations between SNP genotypes and time between seroconversion and AIDS-diagnosis, and one from the top ten associations between SNP genotypes and time between seroconversion and AIDS-related death, had P-values smaller than 0.05 in the French Genomics of Resistance to Immunodeficiency Virus cohort on disease progression. Conclusions Our study emphasizes that the use of different phenotypes in GWAS may be useful to unravel the full spectrum of host genetic factors that may be associated with the clinical course of HIV-1 infection. PMID:21811574

  4. Digital health technology and diabetes management.

    Science.gov (United States)

    Cahn, Avivit; Akirov, Amit; Raz, Itamar

    2018-01-01

    Diabetes care is largely dependent on patient self-management and empowerment, given that patients with diabetes must make numerous daily decisions as to what to eat, when to exercise, and determine their insulin dose and timing if required. In addition, patients and providers are generating vast amounts of data from many sources, including electronic medical records, insulin pumps, sensors, glucometers, and other wearables, as well as evolving genomic, proteomic, metabolomics, and microbiomic data. Multiple digital tools and apps have been developed to assist patients to choose wisely, and to enhance their compliance by using motivational tools and incorporating incentives from social media and gaming techniques. Healthcare teams (HCTs) and health administrators benefit from digital developments that sift through the enormous amounts of patient-generated data. Data are acquired, integrated, analyzed, and presented in a self-explanatory manner, highlighting important trends and items that require attention. The use of decision support systems may propose data-driven actions that, for the most, require final approval by the patient or physician before execution and, once implemented, may improve patient outcomes. The digital diabetes clinic aims to incorporate all digital patient data and provide individually tailored virtual or face-to-face visits to those persons who need them most. Digital diabetes care has demonstrated only modest HbA1c reduction in multiple studies and borderline cost-effectiveness, although patient satisfaction appears to be increased. Better understanding of the barriers to digital diabetes care and identification of unmet needs may yield improved utilization of this evolving technology in a safe, effective, and cost-saving manner. © 2017 Ruijin Hospital, Shanghai Jiaotong University School of Medicine and John Wiley & Sons Australia, Ltd.

  5. Soft tissue-preserving computer-aided impression: a novel concept using ultrasonic 3D-scanning.

    Science.gov (United States)

    Vollborn, Thorsten; Habor, Daniel; Pekam, Fabrice Chuembou; Heger, Stefan; Marotti, Juliana; Reich, Sven; Wolfart, Stefan; Tinschert, Joachim; Radermacher, Klaus

    2014-01-01

    Subgingival preparations are often affected by blood and saliva during impression taking, regardless of whether one is using compound impression techniques or intraoral digital scanning methods. The latter are currently based on optical principles and therefore also need clean and dry surfaces. In contrast, ultrasonic waves are able to non-invasively penetrate gingiva, saliva, and blood, leading to decisive advantages, as cleaning and drying of the oral cavity becomes unnecessary. In addition, the application of ultrasound may facilitate the detection of subgingival structures without invasive manipulation, thereby reducing the risk of secondary infection and treatment time, and increasing patient comfort. Ultrasound devices commonly available for medical application and for the testing of materials are only suitable to a limited extent, as their resolution, precision, and design do not fulfill the requirements for intraoral scanning. The aim of this article is to describe the development of a novel ultrasound technology that enables soft tissue-preserving digital impressions of preparations for the CAD/CAM-based production of dental prostheses. The concept and development of the high-resolution ultrasound technique and the corresponding intraoral scanning system, as well as the integration into the CAD/CAM process chain, is presented.

  6. [Exploring a new method for superimposition of pre-treatment and post-treatment mandibular digital dental casts in adults].

    Science.gov (United States)

    Dai, F F; Liu, Y; Xu, T M; Chen, G

    2018-04-18

    To explore a cone beam computed tomography (CBCT)-independent method for mandibular digital dental cast superimposition to evaluate three-dimensional (3D) mandibular tooth movement after orthodontic treatment in adults, and to evaluate the accuracy of this method. Fifteen post-extraction orthodontic treatment adults from the Department of Orthodontics, Peking University School and Hospital of Stomatology were included. All the patients had four first premolars extracted, and were treated with straight wire appliance. The pre- and post-treatment plaster dental casts and craniofacial CBCT scans were obtained. The plaster dental casts were transferred to digital dental casts by 3D laser scanning, and lateral cephalograms were created from the craniofacial CBCT scans by orthogonal projection. The lateral cephalogram-based mandibular digital dental cast superimposition was achieved by sequential maxillary dental cast superimposition registered on the palatal stable region, occlusal transfer, and adjustment of mandibular rotation and translation obtained from lateral cephalogram superimposition. The accuracy of the lateral cephalogram-based mandibular digital dental cast superimposition method was evaluated with the CBCT-based mandibular digital dental cast superimposition method as the standard reference. After mandibular digital dental cast superimposition using both methods, 3D coordinate system was established, and 3D displacements of the lower bilateral first molars, canines and central incisors were measured. Differences between the two superimposition methods in tooth displacement measurements were assessed using the paired t-test with the level of statistical significance set at Pdigital dental cast superimposition methods in 3D displacements of the lower first molars, and sagittal and vertical displacements of the canines and central incisors; transverse displacements of the canines and central incisors differed by (0.3±0.5) mm with statistical significance

  7. Full cycle rapid scan EPR deconvolution algorithm.

    Science.gov (United States)

    Tseytlin, Mark

    2017-08-01

    Rapid scan electron paramagnetic resonance (RS EPR) is a continuous-wave (CW) method that combines narrowband excitation and broadband detection. Sinusoidal magnetic field scans that span the entire EPR spectrum cause electron spin excitations twice during the scan period. Periodic transient RS signals are digitized and time-averaged. Deconvolution of absorption spectrum from the measured full-cycle signal is an ill-posed problem that does not have a stable solution because the magnetic field passes the same EPR line twice per sinusoidal scan during up- and down-field passages. As a result, RS signals consist of two contributions that need to be separated and postprocessed individually. Deconvolution of either of the contributions is a well-posed problem that has a stable solution. The current version of the RS EPR algorithm solves the separation problem by cutting the full-scan signal into two half-period pieces. This imposes a constraint on the experiment; the EPR signal must completely decay by the end of each half-scan in order to not be truncated. The constraint limits the maximum scan frequency and, therefore, the RS signal-to-noise gain. Faster scans permit the use of higher excitation powers without saturating the spin system, translating into a higher EPR sensitivity. A stable, full-scan algorithm is described in this paper that does not require truncation of the periodic response. This algorithm utilizes the additive property of linear systems: the response to a sum of two inputs is equal the sum of responses to each of the inputs separately. Based on this property, the mathematical model for CW RS EPR can be replaced by that of a sum of two independent full-cycle pulsed field-modulated experiments. In each of these experiments, the excitation power equals to zero during either up- or down-field scan. The full-cycle algorithm permits approaching the upper theoretical scan frequency limit; the transient spin system response must decay within the scan

  8. Should You? May You? Can You? Factors in Selecting Rare Books and Special Collections for Digitization

    Science.gov (United States)

    Gertz, Janet

    2013-01-01

    Selection for digitization is about more than which items to scan. Selection is what shapes the online collections that are built by libraries, archives, historical societies, and other cultural heritage institutions. By selecting well, institutions can concentrate on the parts of their collections that are best suited to digitization, that make…

  9. Search for Genomic Alterations in Monozygotic Twins Discordant for Cleft Lip and/or Palate

    DEFF Research Database (Denmark)

    Kimani, Jane W; Yoshiura, Koh-Ichiro; Shi, Min

    2009-01-01

    consisting of 1,536 SNPs, to scan for genomic alterations in a sample of monozygotic twin pairs with discordant cleft lip and/or palate phenotypes. Paired analysis for deletions, amplifications and loss of heterozygosity, along with sequence verification of SNPs with discordant genotype calls did not reveal...... any genomic discordance between twin pairs in lymphocyte DNA samples. Our results demonstrate that postzygotic genomic alterations are not a common cause of monozygotic twin discordance for isolated cleft lip and/or palate. However, rare or balanced genomic alterations, tissue-specific events...

  10. High-energy x-ray CT and its application for digital engineering

    International Nuclear Information System (INIS)

    Kamimura, H.; Sadaoka, N.

    2005-01-01

    A high-energy x-ray computed tomography system and x-ray CT data handling software have been developed for digital engineering; internal dimension measurement, density analysis, actual and designed shape comparison, STL file generation, and support for reverse engineering and rapid prototyping. The system is designed to collect accurate images in short scanning time (10 s per section) using a MeV-energy electron linear accelerator and highly sensitive semiconductor detectors in order to scan large objects made of aluminum and/or iron. An excellent environment in digital engineering is provided by the software products; 'StereoCooker' for 3D bitmap CAD (rendering, feature extraction, dimensional measurement, and shape comparison, etc.), 'FeatureMaker' for translating bitmap CT data to CAD data including feature information, and 'Wingware' for realizing an Windows PC cluster system 'WINGluster' to apply CT data analysis. (author)

  11. Tablet PC interaction with digital micromirror device (DMD)

    Science.gov (United States)

    Refai, Hakki H.; Dahshan, Mostafa H.; Sluss, James J., Jr.

    2007-02-01

    Digital light processing (DLP) is an innovative display technology that uses an optical switch array, known as a digital micromirror device (DMD), which allows digital control of light. To date, DMDs have been used primarily as high-speed spatial light modulators for projector applications. A tablet PC is a notebook or slate-shaped mobile PC. Its touch screen or digitizing tablet technology allows the user to operate the notebook with a stylus or digital pen instead of using a keyboard or mouse. In this paper, we describe an interface solution that translates any sketch on the tablet PC screen to an identical mirror-copy over the cross-section of the DMD micromirrors such that the image of the sketch can be projected onto a special screen. An algorithm has been created to control each single micromirror of the hundreds of thousands of micromirrors that cover the DMD surface. We demonstrate the successful application of a DMD to a high-speed two-dimensional (2D) scanning environment, acquiring the data from the tablet screen and launching its contents to the projection screen; with very high accuracy up to 13.68 μm x 13.68 μm of mirror pitch.

  12. High-definition television for use in digital endoscopy

    Science.gov (United States)

    Haefliger, Juerg; Lehareinger, Yves; Blessing, Patrick; Niederer, Peter F.; Doswald, Daniel; Felber, Norbert

    2001-01-01

    A novel digital high-definition TV (digital HDTV) system is presented which is adapted to the special characteristics of medical endoscopes. In particular, it has a quadratic image aspect ratio to accommodate round endoscopic images, furthermore, the spatial resolution is 1024 x 1024 pixels thereby approaching the diffraction limit of small endoscopes. It exhibits 24 bits true-color with an adjustable temporal resolution of up to 30 full frames per second in progressive scan. To ensure overall superior performance and high-quality image acquisition and reproduction, complex digital error correction and picture enhancing algorithms are integrated into custom ASICs (Application Specific Integrated Circuit). Additionally, an improved color space transformation is performed in real-time to match the spectral characteristics of the digital camera and the viewing device, allowing for a quantitative judgement of colors. Further features include the conversion of the digital video stream to standard video norms such as Pal or NTSC for recording on analog VCRs, the calculation and evaluation of a focus criterion, which is used to perform passive, stable and reliable auto-focusing and the implementation of an automated illumination control, ensuring proper picture brightness during the whole time of operation.

  13. A genome-wide scan study identifies a single nucleotide substitution in ASIP associated with white versus non-white coat-colour variation in sheep (Ovis aries).

    Science.gov (United States)

    Li, M-H; Tiirikka, T; Kantanen, J

    2014-02-01

    In sheep, coat colour (and pattern) is one of the important traits of great biological, economic and social importance. However, the genetics of sheep coat colour has not yet been fully clarified. We conducted a genome-wide association study of sheep coat colours by genotyping 47 303 single-nucleotide polymorphisms (SNPs) in the Finnsheep population in Finland. We identified 35 SNPs associated with all the coat colours studied, which cover genomic regions encompassing three known pigmentation genes (TYRP1, ASIP and MITF) in sheep. Eighteen of these associations were confirmed in further tests between white versus non-white individuals, but none of the 35 associations were significant in the analysis of only non-white colours. Across the tests, the s66432.1 in ASIP showed significant association (P=4.2 × 10(-11) for all the colours; P=2.3 × 10(-11) for white versus non-white colours) with the variation in coat colours and strong linkage disequilibrium with other significant variants surrounding the ASIP gene. The signals detected around the ASIP gene were explained by differences in white versus non-white alleles. Further, a genome scan for selection for white coat pigmentation identified a strong and striking selection signal spanning ASIP. Our study identified the main candidate gene for the coat colour variation between white and non-white as ASIP, an autosomal gene that has been directly implicated in the pathway regulating melanogenesis. Together with ASIP, the two other newly identified genes (TYRP1 and MITF) in the Finnsheep, bordering associated SNPs, represent a new resource for enriching sheep coat-colour genetics and breeding.

  14. Distance reporting in digital pathology: A study on 950 cases

    Directory of Open Access Journals (Sweden)

    Aleksandar Vodovnik

    2015-01-01

    Full Text Available Background: Increased workload, case complexity, financial constraints, and staffing shortages justify wider implementations of digital pathology. One of its main advantages is distance reporting. Aim: A feasibility study was conducted at our institution in order to achieve comprehensive pathology services available by distance. Methods: One senior pathologist reported 950 cases (3,650 slides by distance during 19 weeks. Slides were scanned by ScanScope AT Turbo (Aperio and digital images accessed through SymPathy (Tieto on a 14" laptop. Mobile phone, mobile broadband, broadband over Wi-Fi and broadband were used for internet connections along with a virtual private network technology (VPN. Lync (Microsoft was tested for one case consultation and resident′s teaching session. Larger displays were accessed when available. Effects of ergonomics and working flexibility on the user experience were observed. Details on network speed, frequency of technical issues, data usage, scanning, and turnaround, were collected and evaluated. Turnaround was compared to in-office microscopic reporting, measured from the registration to sign off. Results: Network speeds varied 1-80 Mbps (median download speed 8-65 Mbps. 20 Mbps were satisfactory for the instant upload of digital images. VPN, image viewer, and laptop failed on two occasions each. An estimated data usage per digital image was 10 MB (1-50 MB. Two cases (15 slides were deferred to microscopic slides (0.21/0.41% due to scanty material and suboptimal slide quality. Additional nine cases (15 slides needed to be rescanned for various reasons (0.95/0.41%. Average turnaround was shorter, and the percentage of cases reported up to 3 days higher (3.13 days/72.25% comparing with in-office microscopic reporting (3.90 days/40.56%. Larger displays improved the most user experience at magnifications over Χ20. Conclusions: Existing IT solutions at our institution allow efficient and reliable distance reporting

  15. Application of FDM three-dimensional printing technology in the digital manufacture of custom edentulous mandible trays

    Science.gov (United States)

    Chen, Hu; Yang, Xu; Chen, Litong; Wang, Yong; Sun, Yuchun

    2016-01-01

    The objective was to establish and evaluate a method for manufacture of custom trays for edentulous jaws using computer aided design and fused deposition modeling (FDM) technologies. A digital method for design the custom trays for edentulous jaws was established. The tissue surface data of ten standard mandibular edentulous plaster models, which was used to design the digital custom tray in a reverse engineering software, were obtained using a 3D scanner. The designed tray was printed by a 3D FDM printing device. Another ten hand-made custom trays were produced as control. The 3-dimentional surface data of models and custom trays was scanned to evaluate the accuracy of reserved impression space, while the difference between digitally made trays and hand-made trays were analyzed. The digitally made custom trays achieved a good matching with the mandibular model, showing higher accuracy than the hand-made ones. There was no significant difference of the reserved space between different models and its matched digitally made trays. With 3D scanning, CAD and FDM technology, an efficient method of custom tray production was established, which achieved a high reproducibility and accuracy. PMID:26763620

  16. Genome-wide detection of selection and other evolutionary forces

    DEFF Research Database (Denmark)

    Xu, Zhuofei; Zhou, Rui

    2015-01-01

    As is well known, pathogenic microbes evolve rapidly to escape from the host immune system and antibiotics. Genetic variations among microbial populations occur frequently during the long-term pathogen–host evolutionary arms race, and individual mutation beneficial for the fitness can be fixed...... to scan genome-wide alignments for evidence of positive Darwinian selection, recombination, and other evolutionary forces operating on the coding regions. In this chapter, we describe an integrative analysis pipeline and its application to tracking featured evolutionary trajectories on the genome...

  17. A Hybrid Soft-computing Method for Image Analysis of Digital Plantar Scanners.

    Science.gov (United States)

    Razjouyan, Javad; Khayat, Omid; Siahi, Mehdi; Mansouri, Ali Alizadeh

    2013-01-01

    Digital foot scanners have been developed in recent years to yield anthropometrists digital image of insole with pressure distribution and anthropometric information. In this paper, a hybrid algorithm containing gray level spatial correlation (GLSC) histogram and Shanbag entropy is presented for analysis of scanned foot images. An evolutionary algorithm is also employed to find the optimum parameters of GLSC and transform function of the membership values. Resulting binary images as the thresholded images are undergone anthropometric measurements taking in to account the scale factor of pixel size to metric scale. The proposed method is finally applied to plantar images obtained through scanning feet of randomly selected subjects by a foot scanner system as our experimental setup described in the paper. Running computation time and the effects of GLSC parameters are investigated in the simulation results.

  18. Validation of Digital Microscopy Compared With Light Microscopy for the Diagnosis of Canine Cutaneous Tumors.

    Science.gov (United States)

    Bertram, Christof A; Gurtner, Corinne; Dettwiler, Martina; Kershaw, Olivia; Dietert, Kristina; Pieper, Laura; Pischon, Hannah; Gruber, Achim D; Klopfleisch, Robert

    2018-07-01

    Integration of new technologies, such as digital microscopy, into a highly standardized laboratory routine requires the validation of its performance in terms of reliability, specificity, and sensitivity. However, a validation study of digital microscopy is currently lacking in veterinary pathology. The aim of the current study was to validate the usability of digital microscopy in terms of diagnostic accuracy, speed, and confidence for diagnosing and differentiating common canine cutaneous tumor types and to compare it to classical light microscopy. Therefore, 80 histologic sections including 17 different skin tumor types were examined twice as glass slides and twice as digital whole-slide images by 6 pathologists with different levels of experience at 4 time points. Comparison of both methods found digital microscopy to be noninferior for differentiating individual tumor types within the category epithelial and mesenchymal tumors, but diagnostic concordance was slightly lower for differentiating individual round cell tumor types by digital microscopy. In addition, digital microscopy was associated with significantly shorter diagnostic time, but diagnostic confidence was lower and technical quality was considered inferior for whole-slide images compared with glass slides. Of note, diagnostic performance for whole-slide images scanned at 200× magnification was noninferior in diagnostic performance for slides scanned at 400×. In conclusion, digital microscopy differs only minimally from light microscopy in few aspects of diagnostic performance and overall appears adequate for the diagnosis of individual canine cutaneous tumors with minor limitations for differentiating individual round cell tumor types and grading of mast cell tumors.

  19. MULTISPECTRAL AIRBORNE LASER SCANNING - A NEW TREND IN THE DEVELOPMENT OF LIDAR TECHNOLOGY

    Directory of Open Access Journals (Sweden)

    Bakuła Krzysztof

    2015-12-01

    Full Text Available Airborne laser scanning (ALS is the one of the most accurate remote sensing techniques for data acquisition where the terrain and its coverage is concerned. Modern scanners have been able to scan in two or more channels (frequencies of the laser recently. This gives the rise to the possibility of obtaining diverse information about an area with the different spectral properties of objects. The paper presents an example of a multispectral ALS system - Titan by Optech - with the possibility of data including the analysis of digital elevation models accuracy and data density. As a result of the study, the high relative accuracy of LiDAR acquisition in three spectral bands was proven. The mean differences between digital terrain models (DTMs were less than 0.03 m. The data density analysis showed the influence of the laser wavelength. The points clouds that were tested had average densities of 25, 23 and 20 points per square metre respectively for green (G, near-infrared (NIR and shortwave-infrared (SWIR lasers. In this paper, the possibility of the generation of colour composites using orthoimages of laser intensity reflectance and its classification capabilities using data from airborne multispectral laser scanning for land cover mapping are also discussed and compared with conventional photogrammetric techniques.

  20. Genomic signal processing for DNA sequence clustering.

    Science.gov (United States)

    Mendizabal-Ruiz, Gerardo; Román-Godínez, Israel; Torres-Ramos, Sulema; Salido-Ruiz, Ricardo A; Vélez-Pérez, Hugo; Morales, J Alejandro

    2018-01-01

    Genomic signal processing (GSP) methods which convert DNA data to numerical values have recently been proposed, which would offer the opportunity of employing existing digital signal processing methods for genomic data. One of the most used methods for exploring data is cluster analysis which refers to the unsupervised classification of patterns in data. In this paper, we propose a novel approach for performing cluster analysis of DNA sequences that is based on the use of GSP methods and the K-means algorithm. We also propose a visualization method that facilitates the easy inspection and analysis of the results and possible hidden behaviors. Our results support the feasibility of employing the proposed method to find and easily visualize interesting features of sets of DNA data.

  1. The Digital Fish Library: using MRI to digitize, database, and document the morphological diversity of fish.

    Science.gov (United States)

    Berquist, Rachel M; Gledhill, Kristen M; Peterson, Matthew W; Doan, Allyson H; Baxter, Gregory T; Yopak, Kara E; Kang, Ning; Walker, H J; Hastings, Philip A; Frank, Lawrence R

    2012-01-01

    Museum fish collections possess a wealth of anatomical and morphological data that are essential for documenting and understanding biodiversity. Obtaining access to specimens for research, however, is not always practical and frequently conflicts with the need to maintain the physical integrity of specimens and the collection as a whole. Non-invasive three-dimensional (3D) digital imaging therefore serves a critical role in facilitating the digitization of these specimens for anatomical and morphological analysis as well as facilitating an efficient method for online storage and sharing of this imaging data. Here we describe the development of the Digital Fish Library (DFL, http://www.digitalfishlibrary.org), an online digital archive of high-resolution, high-contrast, magnetic resonance imaging (MRI) scans of the soft tissue anatomy of an array of fishes preserved in the Marine Vertebrate Collection of Scripps Institution of Oceanography. We have imaged and uploaded MRI data for over 300 marine and freshwater species, developed a data archival and retrieval system with a web-based image analysis and visualization tool, and integrated these into the public DFL website to disseminate data and associated metadata freely over the web. We show that MRI is a rapid and powerful method for accurately depicting the in-situ soft-tissue anatomy of preserved fishes in sufficient detail for large-scale comparative digital morphology. However these 3D volumetric data require a sophisticated computational and archival infrastructure in order to be broadly accessible to researchers and educators.

  2. The Digital Fish Library: using MRI to digitize, database, and document the morphological diversity of fish.

    Directory of Open Access Journals (Sweden)

    Rachel M Berquist

    Full Text Available Museum fish collections possess a wealth of anatomical and morphological data that are essential for documenting and understanding biodiversity. Obtaining access to specimens for research, however, is not always practical and frequently conflicts with the need to maintain the physical integrity of specimens and the collection as a whole. Non-invasive three-dimensional (3D digital imaging therefore serves a critical role in facilitating the digitization of these specimens for anatomical and morphological analysis as well as facilitating an efficient method for online storage and sharing of this imaging data. Here we describe the development of the Digital Fish Library (DFL, http://www.digitalfishlibrary.org, an online digital archive of high-resolution, high-contrast, magnetic resonance imaging (MRI scans of the soft tissue anatomy of an array of fishes preserved in the Marine Vertebrate Collection of Scripps Institution of Oceanography. We have imaged and uploaded MRI data for over 300 marine and freshwater species, developed a data archival and retrieval system with a web-based image analysis and visualization tool, and integrated these into the public DFL website to disseminate data and associated metadata freely over the web. We show that MRI is a rapid and powerful method for accurately depicting the in-situ soft-tissue anatomy of preserved fishes in sufficient detail for large-scale comparative digital morphology. However these 3D volumetric data require a sophisticated computational and archival infrastructure in order to be broadly accessible to researchers and educators.

  3. Volumetric evolution of Surtsey, Iceland, from topographic maps and scanning airborne laser altimetry

    Science.gov (United States)

    Garvin, J.B.; Williams, R.S.; Frawley, J.J.; Krabill, W.B.

    2000-01-01

    The volumetric evolution of Surtsey has been estimated on the basis of digital elevation models derived from NASA scanning airborne laser altimeter surveys (20 July 1998), as well as digitized 1:5,000-scale topographic maps produced by the National Land Survey of Iceland and by Norrman. Subaerial volumes have been computed from co-registered digital elevation models (DEM's) from 6 July 1968, 11 July 1975, 16 July 1993, and 20 July 1998 (scanning airborne laser altimetry), as well as true surface area (above mean sea level). Our analysis suggests that the subaerial volume of Surtsey has been reduced from nearly 0.100 km3 on 6 July 1968 to 0.075 km3 on 20 July 1998. Linear regression analysis of the temporal evolution of Surtsey's subaerial volume indicates that most of its subaerial surface will be at or below mean sea-level by approximately 2100. This assumes a conservative estimate of continuation of the current pace of marine erosion and mass-wasting on the island, including the indurated core of the conduits of the Surtur I and Surtur II eruptive vents. If the conduits are relatively resistant to marine erosion they will become sea stacks after the rest of the island has become a submarine shoal, and some portions of the island could survive for centuries. The 20 July 1998 scanning laser altimeter surveys further indicate rapid enlargement of erosional canyons in the northeastern portion of the partial tephra ring associated with Surtur I. Continued airborne and eventually spaceborne topographic surveys of Surtsey are planned to refine the inter-annual change of its subaerial volume.

  4. Automatic digitization. Experience of magnum 8000 in automatic digitization in EA; Digitalizacion automatica. Experiencias obtenidas durante la utilizacion del sistema magnus 8000 para la digitalizacion automatica en EA

    Energy Technology Data Exchange (ETDEWEB)

    Munoz Garcia, M.

    1995-12-31

    The paper describes the life cycle to be followed for the automatic digitization of files containing rasterised (scanned) images for their conversion into vector files (processable using CAD tools). The main characteristics of each of the five phases: capture, cleaning, conversion, revision and post-processing, that form part of the life cycle, are described. Lastly, the paper gives a comparative analysis of the results obtained using the automatic digitization process and other more conventional methods. (Author)

  5. Accuracy and reproducibility of virtual edentulous casts created by laboratory impression scan protocols.

    Science.gov (United States)

    Peng, Lingyan; Chen, Li; Harris, Bryan T; Bhandari, Bikash; Morton, Dean; Lin, Wei-Shao

    2018-04-24

    Although computer-aided design and computer-aided manufacturing (CAD-CAM) complete removable dental prostheses (CRDPs) have gained popularity, conventional impressions are still common for CAD-CAM CRDP treatment. These need to be digitized and converted into virtual edentulous casts with a laboratory impression scan protocol during prosthesis fabrication. How this can best be accomplished is unclear. The purpose of this in vitro study was to compare the accuracy and reproducibility of virtual edentulous casts created by a dental laboratory laser scanner and a cone-beam computed tomography (CBCT) scanner with a digitized master cast. A master cast was digitized as the virtual reference cast. Ten polyvinyl siloxane impressions were made on the master cast and scanned with the dental laboratory laser scanner and CBCT scanner. The impressions were sprayed with antiglare spray and rescanned. Four groups of virtual study casts (N=40) were created from the impression scans. All virtual study casts and the reference cast were registered with surface-matching software, and the root mean square (RMS) values (representation of overall accuracy) and percentage of measurement data points within 1 standard deviation (SD) of mean RMS values (%, representation of overall reproducibility) among the 4 study groups were measured. Additionally, 95 numeric distance differences (representation of accuracy at each region) were measured in 5 distinct regions: the apex of the denture border, 6 mm from denture border, crest of the ridge, palate, and posterior palatal seal. The repeated-measures ANOVA and post hoc test (t grouping) were used to determine statistical differences (α=.05). The laboratory scanner group had a significantly larger RMS value (4.0 ±0.3 μm, Pvirtual edentulous casts, and the antiglare spray only significantly improved the accuracy and reproducibility of virtual edentulous casts created by the dental laboratory laser scanner. The accuracy of the virtual edentulous

  6. Evidence for use of intraoral scanners under clinical conditions for obtaining full-arch digital impressions is insufficient.

    Science.gov (United States)

    Khraishi, Hadil; Duane, Brett

    2017-03-01

    Data sourcesPubMed, Scopus, Cochrane Library, Web of Science, Embase. Relevant papers were also searched from the reference lists of selected studies. A web search of current manufacturers of intraoral scanners.Study selectionStudies with full-arch digital impressions recorded intraorally that tested any of the following outcomes; validity, repeatability, reproducibility, time efficiency. Patient acceptance of digital impressions were considered for the review.Data extraction and synthesisInitially, only titles of the papers identified from the databases were screened, then further screening of the abstracts of the selected titles was carried out. Then finally, full text articles of the selected abstracts were read and only relevant articles were included in the review. Two examiners assessed the quality of the chosen articles using the QUADAS checklist. Any disagreement was resolved by discussion between the two examiners.ResultsOnly eight studies were found that carried out full-arch intraoral scanning. Four studies reported on validity, repeatability and reproducibility of digital measurements. These studies were included in the qualitative assessment. Two intraoral scanners were tested, Lava COS and iTero. In assessing scanning times and patient perception, six and four studies were included, respectively. A decrease in the scanning time was noted as the operator gained experience.ConclusionsThe literature lacks sufficient evidence to comment on the use of intraoral scanners under clinical conditions. Further studies are needed to properly assess the reliability, accuracy, reproducibility and scanning times of intraoral scans.

  7. A new generation scanning system for the high-speed analysis of nuclear emulsions

    Science.gov (United States)

    Alexandrov, A.; Buonaura, A.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; Di Crescenzo, A.; Galati, G.; Lauria, A.; Montesi, M. C.; Tioukov, V.; Vladymyrov, M.

    2016-06-01

    The development of automatic scanning systems was a fundamental issue for large scale neutrino detectors exploiting nuclear emulsions as particle trackers. Such systems speed up significantly the event analysis in emulsion, allowing the feasibility of experiments with unprecedented statistics. In the early 1990s, R&D programs were carried out by Japanese and European laboratories leading to automatic scanning systems more and more efficient. The recent progress in the technology of digital signal processing and of image acquisition allows the fulfillment of new systems with higher performances. In this paper we report the description and the performance of a new generation scanning system able to operate at the record speed of 84 cm2/hour and based on the Large Angle Scanning System for OPERA (LASSO) software infrastructure developed by the Naples scanning group. Such improvement, reduces the scanning time by a factor 4 with respect to the available systems, allowing the readout of huge amount of nuclear emulsions in reasonable time. This opens new perspectives for the employment of such detectors in a wider variety of applications.

  8. A new generation scanning system for the high-speed analysis of nuclear emulsions

    International Nuclear Information System (INIS)

    Alexandrov, A.; Buonaura, A.; Consiglio, L.; Lellis, G. De; Crescenzo, A. Di; Galati, G.; Lauria, A.; Montesi, M.C.; Tioukov, V.; D'Ambrosio, N.; Vladymyrov, M.

    2016-01-01

    The development of automatic scanning systems was a fundamental issue for large scale neutrino detectors exploiting nuclear emulsions as particle trackers. Such systems speed up significantly the event analysis in emulsion, allowing the feasibility of experiments with unprecedented statistics. In the early 1990s, R and D programs were carried out by Japanese and European laboratories leading to automatic scanning systems more and more efficient. The recent progress in the technology of digital signal processing and of image acquisition allows the fulfillment of new systems with higher performances. In this paper we report the description and the performance of a new generation scanning system able to operate at the record speed of 84 cm 2 /hour and based on the Large Angle Scanning System for OPERA (LASSO) software infrastructure developed by the Naples scanning group. Such improvement, reduces the scanning time by a factor 4 with respect to the available systems, allowing the readout of huge amount of nuclear emulsions in reasonable time. This opens new perspectives for the employment of such detectors in a wider variety of applications.

  9. Evaluation of the accuracy of 7 digital scanners: An in vitro analysis based on 3-dimensional comparisons.

    Science.gov (United States)

    Renne, Walter; Ludlow, Mark; Fryml, John; Schurch, Zach; Mennito, Anthony; Kessler, Ray; Lauer, Abigail

    2017-07-01

    As digital impressions become more common and more digital impression systems are released onto the market, it is essential to systematically and objectively evaluate their accuracy. The purpose of this in vitro study was to evaluate and compare the trueness and precision of 6 intraoral scanners and 1 laboratory scanner in both sextant and complete-arch scenarios. Furthermore, time of scanning was evaluated and correlated with trueness and precision. A custom complete-arch model was fabricated with a refractive index similar to that of tooth structure. Seven digital impression systems were used to scan the custom model for both posterior sextant and complete arch scenarios. Analysis was performed using 3-dimensional metrology software to measure discrepancies between the master model and experimental casts. Of the intraoral scanners, the Planscan was found to have the best trueness and precision while the 3Shape Trios was found to have the poorest for sextant scanning (PiTero >3Shape TRIOS 3 >Carestream 3500 >Planscan >CEREC Omnicam >CEREC Bluecam. The order of precision for complete-arch scanning was as follows: CS3500 >iTero >3Shape D800 >3Shape TRIOS 3 >CEREC Omnicam >Planscan >CEREC Bluecam. For the secondary outcome evaluating the effect time has on trueness and precision, the complete- arch scan time was highly correlated with both trueness (r=0.771) and precision (r=0.771). For sextant scanning, the Planscan was found to be the most precise and true scanner. For complete-arch scanning, the 3Shape Trios was found to have the best balance of speed and accuracy. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  10. High-speed scanning: an improved algorithm

    Science.gov (United States)

    Nachimuthu, A.; Hoang, Khoi

    1995-10-01

    In using machine vision for assessing an object's surface quality, many images are required to be processed in order to separate the good areas from the defective ones. Examples can be found in the leather hide grading process; in the inspection of garments/canvas on the production line; in the nesting of irregular shapes into a given surface... . The most common method of subtracting the total area from the sum of defective areas does not give an acceptable indication of how much of the `good' area can be used, particularly if the findings are to be used for the nesting of irregular shapes. This paper presents an image scanning technique which enables the estimation of useable areas within an inspected surface in terms of the user's definition, not the supplier's claims. That is, how much useable area the user can use, not the total good area as the supplier estimated. An important application of the developed technique is in the leather industry where the tanner (the supplier) and the footwear manufacturer (the user) are constantly locked in argument due to disputed quality standards of finished leather hide, which disrupts production schedules and wasted costs in re-grading, re- sorting... . The developed basic algorithm for area scanning of a digital image will be presented. The implementation of an improved scanning algorithm will be discussed in detail. The improved features include Boolean OR operations and many other innovative functions which aim at optimizing the scanning process in terms of computing time and the accurate estimation of useable areas.

  11. PrionScan: an online database of predicted prion domains in complete proteomes.

    Science.gov (United States)

    Espinosa Angarica, Vladimir; Angulo, Alfonso; Giner, Arturo; Losilla, Guillermo; Ventura, Salvador; Sancho, Javier

    2014-02-05

    Prions are a particular type of amyloids related to a large variety of important processes in cells, but also responsible for serious diseases in mammals and humans. The number of experimentally characterized prions is still low and corresponds to a handful of examples in microorganisms and mammals. Prion aggregation is mediated by specific protein domains with a remarkable compositional bias towards glutamine/asparagine and against charged residues and prolines. These compositional features have been used to predict new prion proteins in the genomes of different organisms. Despite these efforts, there are only a few available data sources containing prion predictions at a genomic scale. Here we present PrionScan, a new database of predicted prion-like domains in complete proteomes. We have previously developed a predictive methodology to identify and score prionogenic stretches in protein sequences. In the present work, we exploit this approach to scan all the protein sequences in public databases and compile a repository containing relevant information of proteins bearing prion-like domains. The database is updated regularly alongside UniprotKB and in its present version contains approximately 28000 predictions in proteins from different functional categories in more than 3200 organisms from all the taxonomic subdivisions. PrionScan can be used in two different ways: database query and analysis of protein sequences submitted by the users. In the first mode, simple queries allow to retrieve a detailed description of the properties of a defined protein. Queries can also be combined to generate more complex and specific searching patterns. In the second mode, users can submit and analyze their own sequences. It is expected that this database would provide relevant insights on prion functions and regulation from a genome-wide perspective, allowing researches performing cross-species prion biology studies. Our database might also be useful for guiding experimentalists

  12. Digital simulation of anodic stripping voltammetry from thin film electrodes

    International Nuclear Information System (INIS)

    Magallanes, J.F.

    1984-01-01

    The anodic stripping voltammetry (ASV) is routinely applied to control of Cu(II) in heavy water in the primary cooling loop of the Nuclear Power Reactor. The anodic stripping voltammetry (ASV) is a very well-known technique in electroanalytical chemistry. However, due to the complexity of the phenomena, it is practised with the fundamentals of empiric considerations. A geometric model for the anodic stripping voltammetry (ASV) from thin film electrodes which can be calculated by explicit digital simulation method is proposed as a possibility of solving the electrochemically reversible, cuasi-reversible and irreversible reactions under linear potential scan and multiple potential scans. (Until now the analytical mathematical method was applied to reversible reactions). All the results are compared with analytical solutions and experimental results and it permits to conclude that the anodic stripping voltammetry (ASV) can be studied with the simplicity and potentialities of explicit digital simulation methods. (M.E.L.) [es

  13. A Clinical Comparative Study of 3-Dimensional Accuracy between Digital and Conventional Implant Impression Techniques.

    Science.gov (United States)

    Alsharbaty, Mohammed Hussein M; Alikhasi, Marzieh; Zarrati, Simindokht; Shamshiri, Ahmed Reza

    2018-02-09

    To evaluate the accuracy of a digital implant impression technique using a TRIOS 3Shape intraoral scanner (IOS) compared to conventional implant impression techniques (pick-up and transfer) in clinical situations. Thirty-six patients who had two implants (Implantium, internal connection) ranging in diameter between 3.8 and 4.8 mm in posterior regions participated in this study after signing a consent form. Thirty-six reference models (RM) were fabricated by attaching two impression copings intraorally, splinted with autopolymerizing acrylic resin, verified by sectioning through the middle of the index, and rejoined again with freshly mixed autopolymerizing acrylic resin pattern (Pattern Resin) with the brush bead method. After that, the splinted assemblies were attached to implant analogs (DANSE) and impressed with type III dental stone (Gypsum Microstone) in standard plastic die lock trays. Thirty-six working casts were fabricated for each conventional impression technique (i.e., pick-up and transfer). Thirty-six digital impressions were made with a TRIOS 3Shape IOS. Eight of the digitally scanned files were damaged; 28 digital scan files were retrieved to STL format. A coordinate-measuring machine (CMM) was used to record linear displacement measurements (x, y, and z-coordinates), interimplant distances, and angular displacements for the RMs and conventionally fabricated working casts. CATIA 3D evaluation software was used to assess the digital STL files for the same variables as the CMM measurements. CMM measurements made on the RMs and conventionally fabricated working casts were compared with 3D software measurements made on the digitally scanned files. Data were statistically analyzed using the generalized estimating equation (GEE) with an exchangeable correlation matrix and linear method, followed by the Bonferroni method for pairwise comparisons (α = 0.05). The results showed significant differences between the pick-up and digital groups in all of the

  14. Comparison of the automated evaluation of phantom mama in digital and digitalized images; Comparacao da avaliacao automatizada do phantom mama em imagens digitais e digitalizadas

    Energy Technology Data Exchange (ETDEWEB)

    Santana, Priscila do Carmo, E-mail: pcs@cdtn.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Fac. de Medicina. Dept. de Propedeutica Complementar; Gomes, Danielle Soares; Oliveira, Marcio Alves; Nogueira, Maria do Socorro, E-mail: mnogue@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Mammography is an essential tool for diagnosis and early detection of breast cancer if it is provided as a very good quality service. The process of evaluating the quality of radiographic images in general, and mammography in particular, can be much more accurate, practical and fast with the help of computer analysis tools. This work compare the automated methodology for the evaluation of scanned digital images the phantom mama. By applied the DIP method techniques was possible determine geometrical and radiometric images evaluated. The evaluated parameters include circular details of low contrast, contrast ratio, spatial resolution, tumor masses, optical density and background in Phantom Mama scanned and digitized images. The both results of images were evaluated. Through this comparison was possible to demonstrate that this automated methodology is presented as a promising alternative for the reduction or elimination of subjectivity in both types of images, but the Phantom Mama present insufficient parameters for spatial resolution evaluation. (author)

  15. INCREASE OF READABILITY AND ACCURACY OF 3D MODELS USING FUSION OF CLOSE RANGE PHOTOGRAMMETRY AND LASER SCANNING

    Directory of Open Access Journals (Sweden)

    M. Gašparović

    2012-07-01

    Full Text Available The development of laser scanning technology has opened a new page in geodesy and enabled an entirely new way of presenting data. Products obtained by the method of laser scanning are used in many sciences, as well as in archaeology. It should be noted that 3D models of archaeological artefacts obtained by laser scanning are fully measurable, written in 1:1 scale and have high accuracy. On the other hand, texture and RGB values of the surface of the object obtained by a laser scanner have lower resolution and poorer radiometric characteristics in relation to the textures captured with a digital camera. Scientific research and the goal of this paper are to increase the accuracy and readability of the 3D model with textures obtained with a digital camera. Laser scanning was performed with triangulation scanner of high accuracy, Vivid 9i (Konica Minolta, while for photogrammetric recording digital camera Nikon D90 with a lens of fixed focal length 20 mm, was used. It is important to stress that a posteriori accuracy score of the global registration of point clouds in the form of the standard deviation was ± 0.136 mm while the average distance was only ± 0.080 mm. Also research has proven that the quality projection texture model increases readability. Recording of archaeological artefacts and making their photorealistic 3D model greatly contributes to archaeology as a science, accelerates processing and reconstruction of the findings. It also allows the presentation of findings to the general public, not just to the experts.

  16. In vitro evaluation of prosthodontic impression on natural dentition: a comparison between traditional and digital techniques

    Science.gov (United States)

    MALAGUTI, G.; ROSSI, R.; MARZIALI, B.; ESPOSITO, A.; BRUNO, G.; DARIOL, C.; DI FIORE, A.

    2016-01-01

    SUMMARY Objectives The aim of this in vitro study is to evaluate the marginal and internal fit of zirconia core crowns manufactured following different digital and traditional workflows. Methods A 6° taper shoulder prepared abutment tooth was used to produce 20 zirconia core crowns using four different scanning techniques: scanned directly with the extraoral lab scanner, scanned with intraoral scanner, dental impressions using individual dental tray and polyether, dental casts from a polyether impressions. Marginal and internal fits were evaluated with digital photography and the silicone replica method. Results Medium marginal gaps were 76,00 μm ± 28.9 for extraoral lab scanner, 80.50 μm ± 36,2 for intraoral scanner, 88.10 μm ± 34,8 for dental impression scan and 112,4 μm ± 37,2 for dental cast scan. Medium internal gaps were 23.20 μm ± 10,3 for extraoral lab scanner, 16.20 μm ± 8.3 for intraoral scanner, 27.20 μm ± 16.7 for dental impression scan and 30.20 μm ± 12.7 for dental cast scan. Conclusion Internal gap were extensively lower than 70 μm described in literature. Marginal fit was higher than ideal values for all the techniques but within the limit of clinical success. Intraoral scanners obtained the best results for internal gap. PMID:28280529

  17. Can Digital Computers Support Ancient Mathematical Consciousness?

    Directory of Open Access Journals (Sweden)

    Aaron Sloman

    2018-05-01

    Full Text Available This paper poses, discusses, but does not definitively answer, the following questions: What sorts of reasoning machinery could the ancient mathematicians, and other intelligent animals, be using for spatial reasoning, before the discovery of modern logical mechanisms? “Diagrams in minds” perhaps? How and why did natural selection produce such machinery? Is there a single package of biological abilities for spatial reasoning, or did different sorts of mathematical competence evolve at different times, forming a “layered” system? Do the layers develop in individuals at different stages? Which components are shared with other intelligent species? Does some or all of the machinery exist at or before birth in humans and if not how and when does it develop, and what is the role of experience in its development? How do brains implement such machinery? Could similar machines be implemented as virtual machines on digital computers, and if not what sorts of non-digital “Super Turing” mechanisms could replicate the required functionality, including discovery of impossibility and necessity? How are impossibility and necessity represented in brains? Are chemical mechanisms required? How could such mechanisms be specified in a genome? Are some not specified in the genome but products of interaction between genome and environment? Does Turing’s work on chemical morphogenesis published shortly before he died indicate that he was interested in this problem? Will the answers to these questions vindicate Immanuel Kant’s claims about the nature of mathematical knowledge, including his claim that mathematical truths are non-empirical, synthetic and necessary? Perhaps it’s time for discussions of consciousness to return to the nature of ancient mathematical consciousness, and related aspects of everyday human and non-human intelligence, usually ignored by consciousness theorists.

  18. The use of 3D surface scanning for the measurement and assessment of the human foot

    Directory of Open Access Journals (Sweden)

    Telfer Scott

    2010-09-01

    Full Text Available Abstract Background A number of surface scanning systems with the ability to quickly and easily obtain 3D digital representations of the foot are now commercially available. This review aims to present a summary of the reported use of these technologies in footwear development, the design of customised orthotics, and investigations for other ergonomic purposes related to the foot. Methods The PubMed and ScienceDirect databases were searched. Reference lists and experts in the field were also consulted to identify additional articles. Studies in English which had 3D surface scanning of the foot as an integral element of their protocol were included in the review. Results Thirty-eight articles meeting the search criteria were included. Advantages and disadvantages of using 3D surface scanning systems are highlighted. A meta-analysis of studies using scanners to investigate the changes in foot dimensions during varying levels of weight bearing was carried out. Conclusions Modern 3D surface scanning systems can obtain accurate and repeatable digital representations of the foot shape and have been successfully used in medical, ergonomic and footwear development applications. The increasing affordability of these systems presents opportunities for researchers investigating the foot and for manufacturers of foot related apparel and devices, particularly those interested in producing items that are customised to the individual. Suggestions are made for future areas of research and for the standardization of the protocols used to produce foot scans.

  19. Digital Culture and Digital Library

    Directory of Open Access Journals (Sweden)

    Yalçın Yalçınkaya

    2016-12-01

    Full Text Available In this study; digital culture and digital library which have a vital connection with each other are examined together. The content of the research consists of the interaction of culture, information, digital culture, intellectual technologies, and digital library concepts. The study is an entry work to integrity of digital culture and digital library theories and aims to expand the symmetry. The purpose of the study is to emphasize the relation between the digital culture and digital library theories acting intersection of the subjects that are examined. Also the perspective of the study is based on examining the literature and analytical evaluation in both studies (digital culture and digital library. Within this context, the methodology of the study is essentially descriptive and has an attribute for the transmission and synthesis of distributed findings produced in the field of the research. According to the findings of the study results, digital culture is an inclusive term that describes the effects of intellectual technologies in the field of information and communication. Information becomes energy and the spectrum of the information is expanding in the vertical rise through the digital culture. In this context, the digital library appears as a new living space of a new environment. In essence, the digital library is information-oriented; has intellectual technology support and digital platform; is in a digital format; combines information resources and tools in relationship/communication/cooperation by connectedness, and also it is the dynamic face of the digital culture in time and space independence. Resolved with the study is that the digital libraries are active and effective in the formation of global knowing and/or mass wisdom in the process of digital culture.

  20. Comparison of the spatial landmark scatter of various 3D digitalization methods.

    Science.gov (United States)

    Boldt, Florian; Weinzierl, Christian; Hertrich, Klaus; Hirschfelder, Ursula

    2009-05-01

    The aim of this study was to compare four different three-dimensional digitalization methods on the basis of the complex anatomical surface of a cleft lip and palate plaster cast, and to ascertain their accuracy when positioning 3D landmarks. A cleft lip and palate plaster cast was digitalized with the SCAN3D photo-optical scanner, the OPTIX 400S laser-optical scanner, the Somatom Sensation 64 computed tomography system and the MicroScribe MLX 3-axis articulated-arm digitizer. First, four examiners appraised by individual visual inspection the surface detail reproduction of the three non-tactile digitalization methods in comparison to the reference plaster cast. The four examiners then localized the landmarks five times at intervals of 2 weeks. This involved simply copying, or spatially tracing, the landmarks from a reference plaster cast to each model digitally reproduced by each digitalization method. Statistical analysis of the landmark distribution specific to each method was performed based on the 3D coordinates of the positioned landmarks. Visual evaluation of surface detail conformity assigned the photo-optical digitalization method an average score of 1.5, the highest subjectively-determined conformity (surpassing computer tomographic and laser-optical methods). The tactile scanning method revealed the lowest degree of 3D landmark scatter, 0.12 mm, and at 1.01 mm the lowest maximum 3D landmark scatter; this was followed by the computer tomographic, photo-optical and laser-optical methods (in that order). This study demonstrates that the landmarks' precision and reproducibility are determined by the complexity of the reference-model surface as well as the digital surface quality and individual ability of each evaluator to capture 3D spatial relationships. The differences in the 3D-landmark scatter values and lowest maximum 3D-landmark scatter between the best and the worst methods showed minor differences. The measurement results in this study reveal that it

  1. A Hybrid Soft-computing Method for Image Analysis of Digital Plantar Scanners

    Science.gov (United States)

    Razjouyan, Javad; Khayat, Omid; Siahi, Mehdi; Mansouri, Ali Alizadeh

    2013-01-01

    Digital foot scanners have been developed in recent years to yield anthropometrists digital image of insole with pressure distribution and anthropometric information. In this paper, a hybrid algorithm containing gray level spatial correlation (GLSC) histogram and Shanbag entropy is presented for analysis of scanned foot images. An evolutionary algorithm is also employed to find the optimum parameters of GLSC and transform function of the membership values. Resulting binary images as the thresholded images are undergone anthropometric measurements taking in to account the scale factor of pixel size to metric scale. The proposed method is finally applied to plantar images obtained through scanning feet of randomly selected subjects by a foot scanner system as our experimental setup described in the paper. Running computation time and the effects of GLSC parameters are investigated in the simulation results. PMID:24083133

  2. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples.

    Science.gov (United States)

    Zhu, Pengyu; Wang, Chenguang; Huang, Kunlun; Luo, Yunbo; Xu, Wentao

    2016-03-18

    Digital polymerase chain reaction (PCR) has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ), sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP) sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO) genome samples using commercial digital PCR detection systems.

  3. A Novel Pretreatment-Free Duplex Chamber Digital PCR Detection System for the Absolute Quantitation of GMO Samples

    Directory of Open Access Journals (Sweden)

    Pengyu Zhu

    2016-03-01

    Full Text Available Digital polymerase chain reaction (PCR has developed rapidly since it was first reported in the 1990s. However, pretreatments are often required during preparation for digital PCR, which can increase operation error. The single-plex amplification of both the target and reference genes may cause uncertainties due to the different reaction volumes and the matrix effect. In the current study, a quantitative detection system based on the pretreatment-free duplex chamber digital PCR was developed. The dynamic range, limit of quantitation (LOQ, sensitivity and specificity were evaluated taking the GA21 event as the experimental object. Moreover, to determine the factors that may influence the stability of the duplex system, we evaluated whether the pretreatments, the primary and secondary structures of the probes and the SNP effect influence the detection. The results showed that the LOQ was 0.5% and the sensitivity was 0.1%. We also found that genome digestion and single nucleotide polymorphism (SNP sites affect the detection results, whereas the unspecific hybridization within different probes had little side effect. This indicated that the detection system was suited for both chamber-based and droplet-based digital PCR. In conclusion, we have provided a simple and flexible way of achieving absolute quantitation for genetically modified organism (GMO genome samples using commercial digital PCR detection systems.

  4. Systems of imaging digital systems in case of glaucoma

    International Nuclear Information System (INIS)

    Fernandez Argones, Liamet; Piloto Diaz, Ibrain; Coba Penna, Maria Josefa; Perez Tamayo, Bertila; Dominguez Randulfe, Marerneda; Trujillo Fonseca, Katia

    2009-01-01

    Now a day we can't consider the strict follow up in Glaucoma without the use of the digital analysis of image system of the optic nerve head and the retinal nerve fiber layer. This is a review about some contributions of Scanning Laser Polarimetry (GDx VCC, Carl Zeiss Meditec, Dublin, CA), Confocal Scanning Laser (Heidelberg Retina Tomograph HRT, Heidelberg Engineering Inc.) and Optical Coherence Tomography (Stratus OCT, Carl Zeiss Meditec, Alemania) in the diagnosis and follow up of Glaucoma. It's considered that objective measurement giving by them must be incorporate in the rigorous analysis of each glaucomatous patient

  5. Influence of abutment tooth geometry on the accuracy of conventional and digital methods of obtaining dental impressions.

    Science.gov (United States)

    Carbajal Mejía, Jeison B; Wakabayashi, Kazumichi; Nakamura, Takashi; Yatani, Hirofumi

    2017-09-01

    Direct (intraoral) and indirect (desktop) digital scanning can record abutment tooth preparations despite their geometry. However, little peer-reviewed information is available regarding the influence of abutment tooth geometry on the accuracy of digital methods of obtaining dental impressions. The purpose of this in vitro study was to evaluate the influence of abutment tooth geometry on the accuracy of conventional and digital methods of obtaining dental impressions in terms of trueness and precision. Crown preparations with known total occlusal convergence (TOC) angles (-8, -6, -4, 0, 4, 8, 12, 16, and 22 degrees) were digitally created from a maxillary left central incisor and printed in acrylic resin. Each of these 9 reference models was scanned with a highly accurate reference scanner and saved in standard tessellation language (STL) format. Then, 5 conventional polyvinyl siloxane (PVS) impressions were made from each reference model, which was poured with Type IV dental stone scanned using both the reference scanner (group PVS) and the desktop scanner and exported as STL files. Additionally, direct digital impressions (intraoral group) of the reference models were made, and the STL files were exported. The STL files from the impressions obtained were compared with the original geometry of the reference model (trueness) and within each test group (precision). Data were analyzed using 2-way ANOVA with the post hoc least significant difference test (α=.05). Overall trueness values were 19.1 μm (intraoral scanner group), 23.5 μm (desktop group), and 26.2 μm (PVS group), whereas overall precision values were 11.9 μm (intraoral), 18.0 μm (PVS), and 20.7 μm (desktop). Simple main effects analysis showed that impressions made with the intraoral scanner were significantly more accurate than those of the PVS and desktop groups when the TOC angle was less than 8 degrees (Pimpression and the TOC angle on the precision of single-tooth dental impressions (F=2

  6. Dental Students' Perceptions of Digital and Conventional Impression Techniques: A Randomized Controlled Trial.

    Science.gov (United States)

    Zitzmann, Nicola U; Kovaltschuk, Irina; Lenherr, Patrik; Dedem, Philipp; Joda, Tim

    2017-10-01

    The aim of this randomized controlled trial was to analyze inexperienced dental students' perceptions of the difficulty and applicability of digital and conventional implant impressions and their preferences including performance. Fifty undergraduate dental students at a dental school in Switzerland were randomly divided into two groups (2×25). Group A first took digital impressions in a standardized phantom model and then conventional impressions, while the procedures were reversed for Group B. Participants were asked to complete a VAS questionnaire (0-100) on the level of difficulty and applicability (user/patient-friendliness) of both techniques. They were asked which technique they preferred and perceived to be more efficient. A quotient of "effective scan time per software-recorded time" (TRIOS) was calculated as an objective quality indicator for intraoral optical scanning (IOS). The majority of students perceived IOS as easier than the conventional technique. Most (72%) preferred the digital approach using IOS to take the implant impression to the conventional method (12%) or had no preference (12%). Although total work was similar for males and females, the TRIOS quotient indicated that male students tended to use their time more efficiently. In this study, dental students with no clinical experience were very capable of acquiring digital tools, indicating that digital impression techniques can be included early in the dental curriculum to help them catch up with ongoing development in computer-assisted technologies used in oral rehabilitation.

  7. Quality assurance of lower limb venous duplex scans performed by vascular surgeons.

    Science.gov (United States)

    Kordowicz, A; Ferguson, G; Salaman, R; Onwudike, M

    2015-02-01

    Duplex scanning is the gold standard for investigating venous reflux; increasingly surgeons perform these scans themselves. There has been no data published analysing the accuracy of Duplex scans performed by vascular surgeons. We aimed to evaluate an objective method of comparing the results of lower limb Duplex scans performed by one consultant vascular surgeon with those performed by a vascular technologist. We assessed 100 legs with symptomatic varicose veins. Each patient underwent two lower limb venous Duplex scans; one performed by a consultant vascular surgeon and one by a vascular technologist. Scan results were randomised and sent to two consultant vascular surgeons blinded to the identity and experience of the sonographer. They were asked to recommend treatment. A k score was calculated in each case to assess the level of agreement between the scans performed by the consultant and the technologist. Eighty-one patients were studied (53 females). The kappa score for assessor 1 was 0.60 (95%CI:0.44-0.75) and for assessor 2 was 0.62 (95%CI:0.48-0.75). k scores >0.60 represent a substantial strength of agreement. Duplex scans performed by this surgeon were comparable to those performed by a vascular technologist. It is possible to quality-assure duplex performed by vascular surgeons without directly observing the scanning process or reviewing digitally recorded images. We propose standardisation of training, assessment and quality assurance for vascular surgeons wishing to perform ultrasound scans.

  8. A fluorescence scanning electron microscope

    International Nuclear Information System (INIS)

    Kanemaru, Takaaki; Hirata, Kazuho; Takasu, Shin-ichi; Isobe, Shin-ichiro; Mizuki, Keiji; Mataka, Shuntaro; Nakamura, Kei-ichiro

    2009-01-01

    Fluorescence techniques are widely used in biological research to examine molecular localization, while electron microscopy can provide unique ultrastructural information. To date, correlative images from both fluorescence and electron microscopy have been obtained separately using two different instruments, i.e. a fluorescence microscope (FM) and an electron microscope (EM). In the current study, a scanning electron microscope (SEM) (JEOL JXA8600 M) was combined with a fluorescence digital camera microscope unit and this hybrid instrument was named a fluorescence SEM (FL-SEM). In the labeling of FL-SEM samples, both Fluolid, which is an organic EL dye, and Alexa Fluor, were employed. We successfully demonstrated that the FL-SEM is a simple and practical tool for correlative fluorescence and electron microscopy.

  9. Digital mammography with high-resolution storage plates (CR) versus full-field digital mammography (CCD) (DR) for microcalcifications and focal lesions - a retrospective clinical histologic analysis (n = 102)

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Lell, M.; Wenkel, E.; Boehner, C.; Dassel, M.S.; Bautz, W.

    2005-01-01

    Purpose: to determine the diagnostic accuracy of microcalcifications and focal lesions in a retrospective clinical-histological study using high-resolution digital phosphor storage plates (hard copy) and full-field digital mammography (hard copy). Materials and methods: from May 2003 to September 2003, 102 patients underwent digital storage plate mammography (CR), using a mammography unit (Mammomat 3000 N, Siemens) in combination with a high resolution (9 lp/mm) digital storage phosphor plate system (pixel size 50 μm) (Fuji/Siemens). After diagnosis and preoperative wire localization, full-field digital mammography (CCD) (DR) was performed with the same exposure parameters. The full-field digital mammography used a CCD-detector (SenoScan) (fisher imaging) with a resolution of 10 Ip/mm and a pixel size of 50 μm. Five investigators determined the diagnosis (BI-RADS trademark I-V) retrospectively after the operation from randomly distributed mediolateral views (hard copy reading). These results were correlated with the final histology. Results: the diagnostic accuracy of digital storage plate mammography (CR) and full-field digital mammography (CCD) (DR) was 73% and 71% for all findings (n = 102), 73% and 71% for microcalcifications (n = 51), and 72% and 70% for focal lesions (n = 51). The overall results showed no difference. Conclusion: our findings indicate the equivalence of high-resolution digital phosphor storage plate mammography (CR) and full-field digital mammography (CCD) (DR). (orig.)

  10. State of the art and trends for digital pathology.

    Science.gov (United States)

    García Rojo, Marcial

    2012-01-01

    Anatomic pathology is a medical specialty where both information management systems and digital images systems paly a most important role. Digital pathology is a new concept that considers all uses of this information, including diagnosis, biomedical research and education. Virtual microscopy or whole slide imaging, resulting in digital slides, is an outreaching technology in anatomic pathology. Limiting factors in the expansion of virtual microscopy are formidable storage dimension, scanning speed, quality of image and cultural change. Anatomic pathology data and images should be an important part of the patient electronic health records as well as of clinical data warehouse, epidemiological or biomedical research databases, and platforms dedicated to translational medicine. Integrating anatomic pathology to the "healthcare enterprise" can only be achieved using existing and emerging medical informatics standards like Digital Imaging and Communications in Medicine (DICOM®1), Health Level Seven (HL7®), and Systematized Nomenclature of Medicine-Clinical Terms (SNOMED CT®), following the recommendations of Integrating the Healthcare Enterprise (IHE®). The consequences of the full digitalization of pathology departments are hard to foresee, but short term issues have arisen that imply interesting challenges for health care standards bodies.

  11. A genome-wide scan for signatures of directional selection in domesticated pigs.

    Science.gov (United States)

    Moon, Sunjin; Kim, Tae-Hun; Lee, Kyung-Tai; Kwak, Woori; Lee, Taeheon; Lee, Si-Woo; Kim, Myung-Jick; Cho, Kyuho; Kim, Namshin; Chung, Won-Hyong; Sung, Samsun; Park, Taesung; Cho, Seoae; Groenen, Martien Am; Nielsen, Rasmus; Kim, Yuseob; Kim, Heebal

    2015-02-25

    Animal domestication involved drastic phenotypic changes driven by strong artificial selection and also resulted in new populations of breeds, established by humans. This study aims to identify genes that show evidence of recent artificial selection during pig domestication. Whole-genome resequencing of 30 individual pigs from domesticated breeds, Landrace and Yorkshire, and 10 Asian wild boars at ~16-fold coverage was performed resulting in over 4.3 million SNPs for 19,990 genes. We constructed a comprehensive genome map of directional selection by detecting selective sweeps using an F ST-based approach that detects directional selection in lineages leading to the domesticated breeds and using a haplotype-based test that detects ongoing selective sweeps within the breeds. We show that candidate genes under selection are significantly enriched for loci implicated in quantitative traits important to pig reproduction and production. The candidate gene with the strongest signals of directional selection belongs to group III of the metabolomics glutamate receptors, known to affect brain functions associated with eating behavior, suggesting that loci under strong selection include loci involved in behaviorial traits in domesticated pigs including tameness. We show that a significant proportion of selection signatures coincide with loci that were previously inferred to affect phenotypic variation in pigs. We further identify functional enrichment related to behavior, such as signal transduction and neuronal activities, for those targets of selection during domestication in pigs.

  12. Genomic diversity within the haloalkaliphilic genus Thioalkalivibrio.

    Science.gov (United States)

    Ahn, Anne-Catherine; Meier-Kolthoff, Jan P; Overmars, Lex; Richter, Michael; Woyke, Tanja; Sorokin, Dimitry Y; Muyzer, Gerard

    2017-01-01

    Thioalkalivibrio is a genus of obligate chemolithoautotrophic haloalkaliphilic sulfur-oxidizing bacteria. Their habitat are soda lakes which are dual extreme environments with a pH range from 9.5 to 11 and salt concentrations up to saturation. More than 100 strains of this genus have been isolated from various soda lakes all over the world, but only ten species have been effectively described yet. Therefore, the assignment of the remaining strains to either existing or novel species is important and will further elucidate their genomic diversity as well as give a better general understanding of this genus. Recently, the genomes of 76 Thioalkalivibrio strains were sequenced. On these, we applied different methods including (i) 16S rRNA gene sequence analysis, (ii) Multilocus Sequence Analysis (MLSA) based on eight housekeeping genes, (iii) Average Nucleotide Identity based on BLAST (ANIb) and MUMmer (ANIm), (iv) Tetranucleotide frequency correlation coefficients (TETRA), (v) digital DNA:DNA hybridization (dDDH) as well as (vi) nucleotide- and amino acid-based Genome BLAST Distance Phylogeny (GBDP) analyses. We detected a high genomic diversity by revealing 15 new "genomic" species and 16 new "genomic" subspecies in addition to the ten already described species. Phylogenetic and phylogenomic analyses showed that the genus is not monophyletic, because four strains were clearly separated from the other Thioalkalivibrio by type strains from other genera. Therefore, it is recommended to classify the latter group as a novel genus. The biogeographic distribution of Thioalkalivibrio suggested that the different "genomic" species can be classified as candidate disjunct or candidate endemic species. This study is a detailed genome-based classification and identification of members within the genus Thioalkalivibrio. However, future phenotypical and chemotaxonomical studies will be needed for a full species description of this genus.

  13. A novel solid-angle tomosynthesis (SAT) scanning scheme

    International Nuclear Information System (INIS)

    Zhang Jin; Yu, Cedric

    2010-01-01

    Purpose: Digital tomosynthesis (DTS) recently gained extensive research interests in both diagnostic and radiation therapy fields. Conventional DTS images are generated by scanning an x-ray source and flat-panel detector pair on opposite sides of an object, with the scanning trajectory on a one-dimensional curve. A novel tomosynthesis method named solid-angle tomosynthesis (SAT) is proposed, where the x-ray source scans on an arbitrary shaped two-dimensional surface. Methods: An iterative algorithm in the form of total variation regulated expectation maximization is developed for SAT image reconstruction. The feasibility and effectiveness of SAT is corroborated by computer simulation studies using three-dimensional (3D) numerical phantoms including a 3D Shepp-Logan phantom and a volumetric CT image set of a human breast. Results: SAT is able to cover more space in Fourier domain more uniformly than conventional DTS. Greater coverage and more isotropy in the frequency domain translate to fewer artifacts and more accurately restored features in the in-plane reconstruction. Conclusions: Comparing with conventional DTS, SAT allows cone-shaped x-ray beams to project from more solid angles, thus provides more coverage in the spatial-frequency domain, resulting in better quality of reconstructed image.

  14. SARS CTL vaccine candidates; HLA supertype-, genome-wide scanning and biochemical validation

    DEFF Research Database (Denmark)

    Sylvester-Hvid, C; Nielsen, M; Lamberth, K

    2004-01-01

    . Exact knowledge of how the immune system handles protein antigens would allow for the identification of such linear sequences directly from genomic/proteomic sequence information (Lauemoller et al., Rev Immunogenet 2001: 2: 477-91). The latter was recently established when a causative coronavirus (SARS...... of the HLA supertypes and identified almost 100 potential vaccine candidates. These should be further validated in SARS survivors and used for vaccine formulation. We suggest that immunobioinformatics may become a fast and valuable tool in rational vaccine design....

  15. SARS CTL vaccine candidates; HLA supertype-, genome-wide scanning and biochemical validation

    DEFF Research Database (Denmark)

    Sylvester-Hvid, C.; Nielsen, Morten; Lamberth, K.

    2004-01-01

    . Exact knowledge of how the immune system handles protein antigens would allow for the identification of such linear sequences directly, from genomic/proteomic sequence information (Lauemoller et al., Rev Immunogenet 2001: 2: 477-91). The latter was recently established when a causative coronavirus (SARS...... of the HLA supertypes and identified almost 100 potential vaccine candidates. These should be further validated in SARS survivors and used for vaccine formulation. We suggest that immunobioinformatics may become a fast and valuable tool in rational vaccine design....

  16. Fulfill Your Digital Preservation Goals with a Budget Studio

    Directory of Open Access Journals (Sweden)

    Yongli Zhou

    2016-04-01

    Full Text Available In order to fulfill digital preservation goals, many institutions use high-end scanners for in-house scanning of historical print and oversize materials. However, high-end scanners’ prices do not fit in many small institutions’ budget. As digital single-lens reflex (DSLR camera technologies advance and camera prices drop quickly, a budget photography studio can help to achieve institutions’ preservation goals.  This paper compares images delivered by a high-end overhead scanner and a consumer level DSLR camera, discusses pros and cons of using each method, demonstrates how to set up a cost efficient shooting studio, and presents a budget estimate for a studio.

  17. Digital Collections, Digital Libraries & the Digitization of Cultural Heritage Information.

    Science.gov (United States)

    Lynch, Clifford

    2002-01-01

    Discusses digital collections and digital libraries. Topics include broadband availability; digital rights protection; content, both non-profit and commercial; digitization of cultural content; sustainability; metadata harvesting protocol; infrastructure; authorship; linking multiple resources; data mining; digitization of reference works;…

  18. [Comparison of digital and visual methods for Ki-67 assessment in invasive breast carcinomas].

    Science.gov (United States)

    Kushnarev, V A; Artemyeva, E S; Kudaybergenova, A G

    2018-01-01

    to compare two methods for quantitative assessment of the proliferative activity index (PAI): a visual estimation method by several investigators and digital image analysis (DIA). The use of the Ki-67 index in the daily clinical practice of a Morbid Anatomy Department is associated with the problem of reproducibility of quantitative assessment of the Ki-67 PAI. Due to the development of digital imaging techniques in morphology, new methods for PAI evaluation using the DIA are proposed. The Ki-67 PAI data obtained during visual assessment and digital image analysis were compared in 104 cases of grades 2-3 breast carcinoma. The histological sections were scanned using a Panoramic III scanner (3D Histech, Hungary) and digital images were obtained. DIA was carried out using the software 3D Histech QuantCenter (3D Histech, Hungary), by marking 3-10 zones. Evaluation of the obtained sections was done independently by two investigators engaged in cancer pathology. The level of agreement between visual and digital methods did not differ significantly (p>0.001). The authors selected a gray area in the range of 10-35% IPA, where the Ki-67 index showed a weak relationship between the analyzed groups (ICC, 0.47). The Ki67 index below 10% and above 35% showed a sufficient reproducibility in the same laboratory. The authors consider that the scanned digital form of a histological section, which can be evaluated using automated software analysis modules, is an independent and objective method to assess proliferative activity for Ki-67 index validation.

  19. A genome-wide linkage scan for dietary energy and nutrient intakes: the Health, Risk Factors, Exercise Training, and Genetics (HERITAGE) Family Study.

    Science.gov (United States)

    Collaku, Agron; Rankinen, Tuomo; Rice, Treva; Leon, Arthur S; Rao, D C; Skinner, James S; Wilmore, Jack H; Bouchard, Claude

    2004-05-01

    A poor diet is a risk factor for chronic diseases such as obesity, cardiovascular disease, hypertension, and some cancers. Twin and family studies suggest that genetic factors potentially influence energy and nutrient intakes. We sought to identify genomic regions harboring genes affecting total energy, carbohydrate, protein, and fat intakes. We performed a genomic scan in 347 white sibling pairs and 99 black sibling pairs. Dietary energy and nutrient intakes were assessed by using Willett's food-frequency questionnaire. Single-point and multipoint Haseman-Elston regression techniques were used to test for linkage. These subjects were part of the Health, Risk Factors, Exercise Training, and Genetics (HERITAGE) Family Study, a multicenter project undertaken by 5 laboratories. In the whites, the strongest evidence of linkage appeared for dietary energy and nutrient intakes on chromosomes 1p21.2 (P = 0.0002) and 20q13.13 (P = 0.00007), and that for fat intake appeared on chromosome 12q14.1 (P = 0.0013). The linkage evidence on chromosomes 1 and 20 related to total energy intake rather than to the intake of specific macronutrients. In the blacks, promising linkages for macronutrient intakes occurred on chromosomes 12q23-q24.21, 1q32.1, and 7q11.1. Several potential candidate genes are encoded in and around the linkage regions on chromosomes 1p21.2, 12q14.1, and 20q13.13. These are the first reported human quantitative trait loci for dietary energy and macronutrient intakes. Further study may refine these quantitative trait loci to identify potential candidate genes for energy and specific macronutrient intakes that would be amenable to more detailed molecular studies.

  20. H. Sapiens Digital: From Digital Immigrants and Digital Natives to Digital Wisdom

    Science.gov (United States)

    Prensky, Marc

    2009-01-01

    As we move further into the 21st century, the digital native/digital immigrant paradigm created by Marc Prensky in 2001 is becoming less relevant. In this article, Prensky suggests that we should focus instead on the development of what he calls "digital wisdom." Arguing that digital technology can make us not just smarter but truly wiser, Prensky…

  1. Digital Dentistry — 3D Printing Applications

    Directory of Open Access Journals (Sweden)

    Zaharia Cristian

    2017-03-01

    Full Text Available Three-dimensional (3D printing is an additive manufacturing method in which a 3D item is formed by laying down successive layers of material. 3D printers are machines that produce representations of objects either planned with a CAD program or scanned with a 3D scanner. Printing is a method for replicating text and pictures, typically with ink on paper. We can print different dental pieces using different methods such as selective laser sintering (SLS, stereolithography, fused deposition modeling, and laminated object manufacturing. The materials are certified for printing individual impression trays, orthodontic models, gingiva mask, and different prosthetic objects. The material can reach a flexural strength of more than 80 MPa. 3D printing takes the effectiveness of digital projects to the production phase. Dental laboratories are able to produce crowns, bridges, stone models, and various orthodontic appliances by methods that combine oral scanning, 3D printing, and CAD/CAM design. Modern 3D printing has been used for the development of prototypes for several years, and it has begun to find its use in the world of manufacturing. Digital technology and 3D printing have significantly elevated the rate of success in dental implantology using custom surgical guides and improving the quality and accuracy of dental work.

  2. Digital Collections, Digital Libraries and the Digitization of Cultural Heritage Information.

    Science.gov (United States)

    Lynch, Clifford

    2002-01-01

    Discusses the development of digital collections and digital libraries. Topics include digitization of cultural heritage information; broadband issues; lack of compelling content; training issues; types of materials being digitized; sustainability; digital preservation; infrastructure; digital images; data mining; and future possibilities for…

  3. Meta-analysis of 32 genome-wide linkage studies of schizophrenia

    Science.gov (United States)

    Ng, MYM; Levinson, DF; Faraone, SV; Suarez, BK; DeLisi, LE; Arinami, T; Riley, B; Paunio, T; Pulver, AE; Irmansyah; Holmans, PA; Escamilla, M; Wildenauer, DB; Williams, NM; Laurent, C; Mowry, BJ; Brzustowicz, LM; Maziade, M; Sklar, P; Garver, DL; Abecasis, GR; Lerer, B; Fallin, MD; Gurling, HMD; Gejman, PV; Lindholm, E; Moises, HW; Byerley, W; Wijsman, EM; Forabosco, P; Tsuang, MT; Hwu, H-G; Okazaki, Y; Kendler, KS; Wormley, B; Fanous, A; Walsh, D; O’Neill, FA; Peltonen, L; Nestadt, G; Lasseter, VK; Liang, KY; Papadimitriou, GM; Dikeos, DG; Schwab, SG; Owen, MJ; O’Donovan, MC; Norton, N; Hare, E; Raventos, H; Nicolini, H; Albus, M; Maier, W; Nimgaonkar, VL; Terenius, L; Mallet, J; Jay, M; Godard, S; Nertney, D; Alexander, M; Crowe, RR; Silverman, JM; Bassett, AS; Roy, M-A; Mérette, C; Pato, CN; Pato, MT; Roos, J Louw; Kohn, Y; Amann-Zalcenstein, D; Kalsi, G; McQuillin, A; Curtis, D; Brynjolfson, J; Sigmundsson, T; Petursson, H; Sanders, AR; Duan, J; Jazin, E; Myles-Worsley, M; Karayiorgou, M; Lewis, CM

    2009-01-01

    A genome scan meta-analysis (GSMA) was carried out on 32 independent genome-wide linkage scan analyses that included 3255 pedigrees with 7413 genotyped cases affected with schizophrenia (SCZ) or related disorders. The primary GSMA divided the autosomes into 120 bins, rank-ordered the bins within each study according to the most positive linkage result in each bin, summed these ranks (weighted for study size) for each bin across studies and determined the empirical probability of a given summed rank (PSR) by simulation. Suggestive evidence for linkage was observed in two single bins, on chromosomes 5q (142-168 Mb) and 2q (103-134 Mb). Genome-wide evidence for linkage was detected on chromosome 2q (119-152 Mb) when bin boundaries were shifted to the middle of the previous bins. The primary analysis met empirical criteria for ‘aggregate’ genome-wide significance, indicating that some or all of 10 bins are likely to contain loci linked to SCZ, including regions of chromosomes 1, 2q, 3q, 4q, 5q, 8p and 10q. In a secondary analysis of 22 studies of European-ancestry samples, suggestive evidence for linkage was observed on chromosome 8p (16-33 Mb). Although the newer genome-wide association methodology has greater power to detect weak associations to single common DNA sequence variants, linkage analysis can detect diverse genetic effects that segregate in families, including multiple rare variants within one locus or several weakly associated loci in the same region. Therefore, the regions supported by this meta-analysis deserve close attention in future studies. PMID:19349958

  4. Copyright and mass digitization a cross-jurisdictional perspective

    CERN Document Server

    Borghi, Maurizio

    2013-01-01

    In an age where works are increasingly being used, not only as works in the traditional sense, but also as carriers of data from which information may be automatically extracted for various purposes, Borghi and Karapapa consider whether mass digitisation is consistent with existing copyright principles, and ultimately whether copyright protection needs to be redefined, and if so how? The work considers the activities involved in the process of mass digitization identifying impediments to the increasing number of such projects such as the inapplicability of copyright exceptions, difficulties in rights clearance, and the issue of 'orphan' and out-of-print works. It goes on to examine the concept of 'use' of works in light of mass digital technologies and how it impinges on copyright law and principles; for example considering whether scanning and using optical character recognition in mass digital projects qualify as transformative use, or whether text mining on digitial repositories should be a permitted act...

  5. High contrast imaging and flexible photomanipulation for quantitative in vivo multiphoton imaging with polygon scanning microscope.

    Science.gov (United States)

    Li, Yongxiao; Montague, Samantha J; Brüstle, Anne; He, Xuefei; Gillespie, Cathy; Gaus, Katharina; Gardiner, Elizabeth E; Lee, Woei Ming

    2018-02-28

    In this study, we introduce two key improvements that overcome limitations of existing polygon scanning microscopes while maintaining high spatial and temporal imaging resolution over large field of view (FOV). First, we proposed a simple and straightforward means to control the scanning angle of the polygon mirror to carry out photomanipulation without resorting to high speed optical modulators. Second, we devised a flexible data sampling method directly leading to higher image contrast by over 2-fold and digital images with 100 megapixels (10 240 × 10 240) per frame at 0.25 Hz. This generates sub-diffraction limited pixels (60 nm per pixels over the FOV of 512 μm) which increases the degrees of freedom to extract signals computationally. The unique combined optical and digital control recorded fine fluorescence recovery after localized photobleaching (r ~10 μm) within fluorescent giant unilamellar vesicles and micro-vascular dynamics after laser-induced injury during thrombus formation in vivo. These new improvements expand the quantitative biological-imaging capacity of any polygon scanning microscope system. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Draft genome of the leopard gecko, Eublepharis macularius.

    Science.gov (United States)

    Xiong, Zijun; Li, Fang; Li, Qiye; Zhou, Long; Gamble, Tony; Zheng, Jiao; Kui, Ling; Li, Cai; Li, Shengbin; Yang, Huanming; Zhang, Guojie

    2016-10-26

    Geckos are among the most species-rich reptile groups and the sister clade to all other lizards and snakes. Geckos possess a suite of distinctive characteristics, including adhesive digits, nocturnal activity, hard, calcareous eggshells, and a lack of eyelids. However, one gecko clade, the Eublepharidae, appears to be the exception to most of these 'rules' and lacks adhesive toe pads, has eyelids, and lays eggs with soft, leathery eggshells. These differences make eublepharids an important component of any investigation into the underlying genomic innovations contributing to the distinctive phenotypes in 'typical' geckos. We report high-depth genome sequencing, assembly, and annotation for a male leopard gecko, Eublepharis macularius (Eublepharidae). Illumina sequence data were generated from seven insert libraries (ranging from 170 to 20 kb), representing a raw sequencing depth of 136X from 303 Gb of data, reduced to 84X and 187 Gb after filtering. The assembled genome of 2.02 Gb was close to the 2.23 Gb estimated by k-mer analysis. Scaffold and contig N50 sizes of 664 and 20 kb, respectively, were comparable to the previously published Gekko japonicus genome. Repetitive elements accounted for 42 % of the genome. Gene annotation yielded 24,755 protein-coding genes, of which 93 % were functionally annotated. CEGMA and BUSCO assessment showed that our assembly captured 91 % (225 of 248) of the core eukaryotic genes, and 76 % of vertebrate universal single-copy orthologs. Assembly of the leopard gecko genome provides a valuable resource for future comparative genomic studies of geckos and other squamate reptiles.

  7. Genomic and Genetic Diversity within the Pseudomonas fluorescens Complex.

    Directory of Open Access Journals (Sweden)

    Daniel Garrido-Sanz

    Full Text Available The Pseudomonas fluorescens complex includes Pseudomonas strains that have been taxonomically assigned to more than fifty different species, many of which have been described as plant growth-promoting rhizobacteria (PGPR with potential applications in biocontrol and biofertilization. So far the phylogeny of this complex has been analyzed according to phenotypic traits, 16S rDNA, MLSA and inferred by whole-genome analysis. However, since most of the type strains have not been fully sequenced and new species are frequently described, correlation between taxonomy and phylogenomic analysis is missing. In recent years, the genomes of a large number of strains have been sequenced, showing important genomic heterogeneity and providing information suitable for genomic studies that are important to understand the genomic and genetic diversity shown by strains of this complex. Based on MLSA and several whole-genome sequence-based analyses of 93 sequenced strains, we have divided the P. fluorescens complex into eight phylogenomic groups that agree with previous works based on type strains. Digital DDH (dDDH identified 69 species and 75 subspecies within the 93 genomes. The eight groups corresponded to clustering with a threshold of 31.8% dDDH, in full agreement with our MLSA. The Average Nucleotide Identity (ANI approach showed inconsistencies regarding the assignment to species and to the eight groups. The small core genome of 1,334 CDSs and the large pan-genome of 30,848 CDSs, show the large diversity and genetic heterogeneity of the P. fluorescens complex. However, a low number of strains were enough to explain most of the CDSs diversity at core and strain-specific genomic fractions. Finally, the identification and analysis of group-specific genome and the screening for distinctive characters revealed a phylogenomic distribution of traits among the groups that provided insights into biocontrol and bioremediation applications as well as their role as

  8. Accuracy of Buccal Scan Procedures for the Registration of Habitual Intercuspation.

    Science.gov (United States)

    Zimmermann, M; Ender, A; Attin, T; Mehl, A

    2018-04-09

    Accurate reproduction of the jaw relationship is important in many fields of dentistry. Maximum intercuspation can be registered with digital buccal scan procedures implemented in the workflow of many intraoral scanning systems. The aim of this study was to investigate the accuracy of buccal scan procedures with intraoral scanning devices for the registration of habitual intercuspation in vivo. The hypothesis was that there is no statistically significant difference for buccal scan procedures compared to registration methods with poured model casts. Ten individuals (full dentition, no dental rehabilitations) were subjects for five different habitual intercuspation registration methods: (CI) poured model casts, manual hand registration, buccal scan with inEOS X5; (BC) intraoral scan, buccal scan with CEREC Bluecam; (OC4.2) intraoral scan, buccal scan with CEREC Omnicam software version 4.2; (OC4.5β) intraoral scan, buccal scan with CEREC Omnicam version 4.5β; and (TR) intraoral scan, buccal scan with Trios 3. Buccal scan was repeated three times. Analysis of rotation (Rot) and translation (Trans) parameters was performed with difference analysis software (OraCheck). Statistical analysis was performed with one-way analysis of variance and the post hoc Scheffé test ( p0.05) differences in terms of translation between groups CI_Trans (98.74±112.01 μm), BC_Trans (84.12±64.95 μm), OC4.2_Trans (60.70±35.08 μm), OC4.5β_Trans (68.36±36.67 μm), and TR_Trans (66.60±64.39 μm). For rotation, there were no significant differences ( p>0.05) for groups CI_Rot (0.23±0.25°), BC_Rot (0.73±0.52°), OC4.2_Rot (0.45±0.31°), OC4.5β_Rot (0.50±0.36°), and TR_Rot (0.47±0.65°). Intraoral scanning devices allow the reproduction of the static relationship of the maxillary and mandibular teeth with the same accuracy as registration methods with poured model casts.

  9. Earth analog image digitization of field, aerial, and lab experiment studies for Planetary Data System archiving.

    Science.gov (United States)

    Williams, D. A.; Nelson, D. M.

    2017-12-01

    A portion of the earth analog image archive at the Ronald Greeley Center for Planetary Studies (RGCPS)-the NASA Regional Planetary Information Facility at Arizona State University-is being digitized and will be added to the Planetary Data System (PDS) for public use. This will be a first addition of terrestrial data to the PDS specifically for comparative planetology studies. Digitization is separated into four tasks. First is the scanning of aerial photographs of volcanic and aeolian structures and flows. The second task is to scan field site images taken from ground and low-altitude aircraft of volcanic structures, lava flows, lava tubes, dunes, and wind streaks. The third image set to be scanned includes photographs of lab experiments from the NASA Planetary Aeolian Laboratory wind tunnels, vortex generator, and of wax models. Finally, rare NASA documents are being scanned and formatted as PDF files. Thousands of images are to be scanned for this project. Archiving of the data will follow the PDS4 standard, where the entire project is classified as a single bundle, with individual subjects (i.e., the Amboy Crater volcanic structure in the Mojave Desert of California) as collections. Within the collections, each image is considered a product, with a unique ID and associated XML document. Documents describing the image data, including the subject and context, will be included with each collection. Once complete, the data will be hosted by a PDS data node and available for public search and download. As one of the first earth analog datasets to be archived by the PDS, this project could prompt the digitizing and making available of historic datasets from other facilities for the scientific community.

  10. Genome analysis methods: Sorghum bicolor [PGDBj Registered plant list, Marker list, QTL list, Plant DB link and Genome analysis methods[Archive

    Lifescience Database Archive (English)

    Full Text Available Sorghum bicolor Finished 2n=20 760 Mb 2009 Sanger (Clone-based) 10,717,203 reads 7...30 Mb 8.5x Arachne2 v.20060705 3,304 12,873 BLAST, GenomeScan 34,496 (Sbi1.4) JGI; http://www.phytozome.net/sorghum Sbi1 Sbi1.4 10.1038/nature07723 19189423 ...

  11. Accuracy of single-tooth restorations based on intraoral digital and conventional impressions in patients.

    Science.gov (United States)

    Boeddinghaus, Moritz; Breloer, Eva Sabina; Rehmann, Peter; Wöstmann, Bernd

    2015-11-01

    The purpose of this clinical study was to compare the marginal fit of dental crowns based on three different intraoral digital and one conventional impression methods. Forty-nine teeth of altogether 24 patients were prepared to be treated with full-coverage restorations. Digital impressions were made using three intraoral scanners: Sirona CEREC AC Omnicam (OCam), Heraeus Cara TRIOS and 3M Lava True Definition (TDef). Furthermore, a gypsum model based on a conventional impression (EXA'lence, GC, Tokyo, Japan) was scanned with a standard laboratory scanner (3Shape D700). Based on the dataset obtained, four zirconia copings per tooth were produced. The marginal fit of the copings in the patient's mouth was assessed employing a replica technique. Overall, seven measurement copings did not fit and, therefore, could not be assessed. The marginal gap was 88 μm (68-136 μm) [median/interquartile range] for the TDef, 112 μm (94-149 μm) for the Cara TRIOS, 113 μm (81-157 μm) for the laboratory scanner and 149 μm (114-218 μm) for the OCam. There was a statistically significant difference between the OCam and the other groups (p < 0.05). Within the limitations of this study, it can be concluded that zirconia copings based on intraoral scans and a laboratory scans of a conventional model are comparable to one another with regard to their marginal fit. Regarding the results of this study, the digital intraoral impression can be considered as an alternative to a conventional impression with a consecutive digital workflow when the finish line is clearly visible and it is possible to keep it dry.

  12. Accuracy of two digital implant impression systems based on confocal microscopy with variations in customized software and clinical parameters.

    Science.gov (United States)

    Giménez, Beatriz; Pradíes, Guillermo; Martínez-Rus, Francisco; Özcan, Mutlu

    2015-01-01

    To evaluate the accuracy of two digital impression systems based on the same technology but different postprocessing correction modes of customized software, with consideration of several clinical parameters. A maxillary master model with six implants located in the second molar, second premolar, and lateral incisor positions was fitted with six cylindrical scan bodies. Scan bodies were placed at different angulations or depths apical to the gingiva. Two experienced and two inexperienced operators performed scans with either 3D Progress (MHT) or ZFX Intrascan (Zimmer Dental). Five different distances between implants (scan bodies) were measured, yielding five data points per impression and 100 per impression system. Measurements made with a high-accuracy three-dimensional coordinate measuring machine (CMM) of the master model acted as the true values. The values obtained from the digital impressions were subtracted from the CMM values to identify the deviations. The differences between experienced and inexperienced operators and implant angulation and depth were compared statistically. Experience of the operator, implant angulation, and implant depth were not associated with significant differences in deviation from the true values with both 3D Progress and ZFX Intrascan. Accuracy in the first scanned quadrant was significantly better with 3D Progress, but ZFX Intrascan presented better accuracy in the full arch. Neither of the two systems tested would be suitable for digital impression of multiple-implant prostheses. Because of the errors, further development of both systems is required.

  13. Integrated three-dimensional digital assessment of accuracy of anterior tooth movement using clear aligners

    OpenAIRE

    Zhang, Xiao-Juan; He, Li; Guo, Hong-Ming; Tian, Jie; Bai, Yu-Xing; Li, Song

    2015-01-01

    Objective To assess the accuracy of anterior tooth movement using clear aligners in integrated three-dimensional digital models. Methods Cone-beam computed tomography was performed before and after treatment with clear aligners in 32 patients. Plaster casts were laser-scanned for virtual setup and aligner fabrication. Differences in predicted and achieved root and crown positions of anterior teeth were compared on superimposed maxillofacial digital images and virtual models and analyzed by St...

  14. Pulmonary ventilation in children digital subtraction study

    International Nuclear Information System (INIS)

    Schmit, P.; Faure, C.; Sardet, A.; Bacques, O.

    1985-01-01

    Digital technique such as used in digital angiography can be used to study areas which lucency varies with time. A TID technique (time interval difference) has been used to study the lucency variation of the lung in children. This method has been used in 130 children with a mean age of 2 years and 8 months. In 85 children, the TID was normal: 5 false negative studies were found in this group. In the other 47 cases, the anomaly of the TID was due to a perfusion or a ventilation anomaly or both. No false positive are found. In 13 patients, comparison between the TID findings and the perfusion and ventilation nuclear scan was possible. In 9 patients, the correlation was excellent, the TID giving more some informations about the pulmonary mixic [fr

  15. A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing

    International Nuclear Information System (INIS)

    Low, Daniel A.; Nystrom, Michelle; Kalinin, Eugene; Parikh, Parag; Dempsey, James F.; Bradley, Jeffrey D.; Mutic, Sasa; Wahab, Sasha H.; Islam, Tareque; Christensen, Gary; Politte, David G.; Whiting, Bruce R.

    2003-01-01

    Breathing motion is a significant source of error in radiotherapy treatment planning for the thorax and upper abdomen. Accounting for breathing motion has a profound effect on the size of conformal radiation portals employed in these sites. Breathing motion also causes artifacts and distortions in treatment planning computed tomography (CT) scans acquired during free breathing and also causes a breakdown of the assumption of the superposition of radiation portals in intensity-modulated radiation therapy, possibly leading to significant dose delivery errors. Proposed voluntary and involuntary breath-hold techniques have the potential for reducing or eliminating the effects of breathing motion, however, they are limited in practice, by the fact that many lung cancer patients cannot tolerate holding their breath. We present an alternative solution to accounting for breathing motion in radiotherapy treatment planning, where multislice CT scans are collected simultaneously with digital spirometry over many free breathing cycles to create a four-dimensional (4-D) image set, where tidal lung volume is the additional dimension. An analysis of this 4-D data leads to methods for digital-spirometry, based elimination or accounting of breathing motion artifacts in radiotherapy treatment planning for free breathing patients. The 4-D image set is generated by sorting free-breathing multislice CT scans according to user-defined tidal-volume bins. A multislice CT scanner is operated in the cine mode, acquiring 15 scans per couch position, while the patient undergoes simultaneous digital-spirometry measurements. The spirometry is used to retrospectively sort the CT scans by their correlated tidal lung volume within the patient's normal breathing cycle. This method has been prototyped using data from three lung cancer patients. The actual tidal lung volumes agreed with the specified bin volumes within standard deviations ranging between 22 and 33 cm 3 . An analysis of sagittal and

  16. An international collaborative family-based whole genome quantitative trait linkage scan for myopic refractive error

    DEFF Research Database (Denmark)

    Abbott, Diana; Li, Yi-Ju; Guggenheim, Jeremy A

    2012-01-01

    To investigate quantitative trait loci linked to refractive error, we performed a genome-wide quantitative trait linkage analysis using single nucleotide polymorphism markers and family data from five international sites....

  17. Genome-wide association scan meta-analysis identifies three loci influencing adiposity and fat distribution

    NARCIS (Netherlands)

    C.M. Lindgren (Cecilia); I.M. Heid (Iris); J.C. Randall (Joshua); C. Lamina (Claudia); V. Steinthorsdottir (Valgerdur); L. Qi (Lu); E.K. Speliotes (Elizabeth); G. Thorleifsson (Gudmar); C.J. Willer (Cristen); B.M. Herrera (Blanca); A.U. Jackson (Anne); N. Lim (Noha); P. Scheet (Paul); N. Soranzo (Nicole); N. Amin (Najaf); Y.S. Aulchenko (Yurii); J.C. Chambers (John); A. Drong (Alexander); J. Luan; H.N. Lyon (Helen); F. Rivadeneira Ramirez (Fernando); S. Sanna (Serena); N.J. Timpson (Nicholas); M.C. Zillikens (Carola); H.Z. Jing; P. Almgren (Peter); S. Bandinelli (Stefania); A.J. Bennett (Amanda); R.N. Bergman (Richard); L.L. Bonnycastle (Lori); S. Bumpstead (Suzannah); S.J. Chanock (Stephen); L. Cherkas (Lynn); P.S. Chines (Peter); L. Coin (Lachlan); C. Cooper (Charles); G. Crawford (Gabe); A. Doering (Angela); A. Dominiczak (Anna); A.S.F. Doney (Alex); S. Ebrahim (Shanil); P. Elliott (Paul); M.R. Erdos (Michael); K. Estrada Gil (Karol); L. Ferrucci (Luigi); G. Fischer (Guido); N.G. Forouhi (Nita); C. Gieger (Christian); H. Grallert (Harald); C.J. Groves (Christopher); S.M. Grundy (Scott); C. Guiducci (Candace); D. Hadley (David); A. Hamsten (Anders); A.S. Havulinna (Aki); A. Hofman (Albert); R. Holle (Rolf); J.W. Holloway (John); T. Illig (Thomas); B. Isomaa (Bo); L.C. Jacobs (Leonie); K. Jameson (Karen); P. Jousilahti (Pekka); F. Karpe (Fredrik); J. Kuusisto (Johanna); J. Laitinen (Jaana); G.M. Lathrop (Mark); D.A. Lawlor (Debbie); M. Mangino (Massimo); W.L. McArdle (Wendy); T. Meitinger (Thomas); M.A. Morken (Mario); A.P. Morris (Andrew); P. Munroe (Patricia); N. Narisu (Narisu); A. Nordström (Anna); B.A. Oostra (Ben); C.N.A. Palmer (Colin); F. Payne (Felicity); J. Peden (John); I. Prokopenko (Inga); F. Renström (Frida); A. Ruokonen (Aimo); V. Salomaa (Veikko); M.S. Sandhu (Manjinder); L.J. Scott (Laura); A. Scuteri (Angelo); K. Silander (Kaisa); K. Song (Kijoung); X. Yuan (Xin); H.M. Stringham (Heather); A.J. Swift (Amy); T. Tuomi (Tiinamaija); M. Uda (Manuela); P. Vollenweider (Peter); G. Waeber (Gérard); C. Wallace (Chris); G.B. Walters (Bragi); M.N. Weedon (Michael); J.C.M. Witteman (Jacqueline); C. Zhang (Cuilin); M. Caulfield (Mark); F.S. Collins (Francis); G.D. Smith; I.N.M. Day (Ian); P.W. Franks (Paul); A.T. Hattersley (Andrew); F.B. Hu (Frank); M.-R. Jarvelin (Marjo-Riitta); A. Kong (Augustine); J.S. Kooner (Jaspal); M. Laakso (Markku); E. Lakatta (Edward); V. Mooser (Vincent); L. Peltonen (Leena Johanna); N.J. Samani (Nilesh); T.D. Spector (Timothy); D.P. Strachan (David); T. Tanaka (Toshiko); J. Tuomilehto (Jaakko); A.G. Uitterlinden (André); P. Tikka-Kleemola (Päivi); N.J. Wareham (Nick); H. Watkins (Hugh); D. Waterworth (Dawn); M. Boehnke (Michael); P. Deloukas (Panagiotis); L. Groop (Leif); D.J. Hunter (David); U. Thorsteinsdottir (Unnur); D. Schlessinger (David); H.E. Wichmann (Erich); T.M. Frayling (Timothy); G.R. Abecasis (Gonçalo); J.N. Hirschhorn (Joel); R.J.F. Loos (Ruth); J-A. Zwart (John-Anker); K.L. Mohlke (Karen); I.E. Barroso (Inês); M.I. McCarthy (Mark)

    2009-01-01

    textabstractTo identify genetic loci influencing central obesity and fat distribution, we performed a meta-analysis of 16 genome-wide association studies (GWAS, N = 38,580) informative for adult waist circumference (WC) and waist-hip ratio (WHR). We selected 26 SNPs for follow-up, for which the

  18. Development of Three-Dimensional Dental Scanning Apparatus Using Structured Illumination

    OpenAIRE

    Ahn, Jae Sung; Park, Anjin; Kim, Ju Wan; Lee, Byeong Ha; Eom, Joo Beom

    2017-01-01

    We demonstrated a three-dimensional (3D) dental scanning apparatus based on structured illumination. A liquid lens was used for tuning focus and a piezomotor stage was used for the shift of structured light. A simple algorithm, which detects intensity modulation, was used to perform optical sectioning with structured illumination. We reconstructed a 3D point cloud, which represents the 3D coordinates of the digitized surface of a dental gypsum cast by piling up sectioned images. We performed ...

  19. Radiation dose reduction in the evaluation of scoliosis: an application of digital radiography

    International Nuclear Information System (INIS)

    Kushner, D.C.; Cleveland, R.H.; Herman, T.E.; Zaleske, D.J.; Ehrlich, M.G.; Correia, J.A.

    1986-01-01

    This report documents the clinical testing of scanning beam digital radiography as an imaging method in patients with scoliosis. This type of digital imaging requires a skin exposure of only 2.4 mR (0.619 microC/kg) per image, compared with the lowest possible posteroanterior screen-film exposure of 10 mR (2.58 microC/kg) at the chest and 60 mR (15.48 microC/kg) at the lumbar spine. Digital radiographic and screen-film images were obtained on multiple test objects and 273 patients. Scoliosis measurements using screen-film radiographs and digital radiographs were comparable to within a mean difference of 1 degrees at many different degrees of severity. The low-dose digital images were found to be useful and accurate for the detection and measurement of scoliosis after the first screen-film radiographs have excluded tumors and structural abnormalities

  20. Genomic Signatures of Sexual Conflict.

    Science.gov (United States)

    Kasimatis, Katja R; Nelson, Thomas C; Phillips, Patrick C

    2017-10-30

    Sexual conflict is a specific class of intergenomic conflict that describes the reciprocal sex-specific fitness costs generated by antagonistic reproductive interactions. The potential for sexual conflict is an inherent property of having a shared genome between the sexes and, therefore, is an extreme form of an environment-dependent fitness effect. In this way, many of the predictions from environment-dependent selection can be used to formulate expected patterns of genome evolution under sexual conflict. However, the pleiotropic and transmission constraints inherent to having alleles move across sex-specific backgrounds from generation to generation further modulate the anticipated signatures of selection. We outline methods for detecting candidate sexual conflict loci both across and within populations. Additionally, we consider the ability of genome scans to identify sexually antagonistic loci by modeling allele frequency changes within males and females due to a single generation of selection. In particular, we highlight the need to integrate genotype, phenotype, and functional information to truly distinguish sexual conflict from other forms of sexual differentiation. © The American Genetic Association 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  1. The Global Genome Biodiversity Network (GGBN) Data Standard specification

    Science.gov (United States)

    Droege, G.; Barker, K.; Seberg, O.; Coddington, J.; Benson, E.; Berendsohn, W. G.; Bunk, B.; Butler, C.; Cawsey, E. M.; Deck, J.; Döring, M.; Flemons, P.; Gemeinholzer, B.; Güntsch, A.; Hollowell, T.; Kelbert, P.; Kostadinov, I.; Kottmann, R.; Lawlor, R. T.; Lyal, C.; Mackenzie-Dodds, J.; Meyer, C.; Mulcahy, D.; Nussbeck, S. Y.; O'Tuama, É.; Orrell, T.; Petersen, G.; Robertson, T.; Söhngen, C.; Whitacre, J.; Wieczorek, J.; Yilmaz, P.; Zetzsche, H.; Zhang, Y.; Zhou, X.

    2016-01-01

    Genomic samples of non-model organisms are becoming increasingly important in a broad range of studies from developmental biology, biodiversity analyses, to conservation. Genomic sample definition, description, quality, voucher information and metadata all need to be digitized and disseminated across scientific communities. This information needs to be concise and consistent in today’s ever-increasing bioinformatic era, for complementary data aggregators to easily map databases to one another. In order to facilitate exchange of information on genomic samples and their derived data, the Global Genome Biodiversity Network (GGBN) Data Standard is intended to provide a platform based on a documented agreement to promote the efficient sharing and usage of genomic sample material and associated specimen information in a consistent way. The new data standard presented here build upon existing standards commonly used within the community extending them with the capability to exchange data on tissue, environmental and DNA sample as well as sequences. The GGBN Data Standard will reveal and democratize the hidden contents of biodiversity biobanks, for the convenience of everyone in the wider biobanking community. Technical tools exist for data providers to easily map their databases to the standard. Database URL: http://terms.tdwg.org/wiki/GGBN_Data_Standard PMID:27694206

  2. Research on defect detection from incomplete scanning of X-ray

    International Nuclear Information System (INIS)

    Zhang Shunli; Zhang Dinghua; Cheng Yunyong; Li Xiaolin

    2011-01-01

    Computed tomography (CT) is an advanced means of non-destructive testing, which has been widely used in medical and industrial fields. Aiming at the non-destructive testing problem of large industrial components, It presents a defect detection method from incomplete scanning of X-ray. Firstly, a set of incomplete scanning projection data before using the component has been obtained, then reconstruct them by algebraic re- construction technique (ART), and take the reconstructed images as the norm images. Then, the incomplete projection data of different times during the use of the component has been obtained, and reconstruct them by ART algorithm. Finally, It makes digital subtraction operation by the reconstructed images and the norm images, the defection can be detected clearly and intuitively from the subtraction image. Experimental result shows the proposed method is effective. (authors)

  3. Digital Humanities and networked digital media

    DEFF Research Database (Denmark)

    Finnemann, Niels Ole

    2014-01-01

    This article discusses digital humanities and the growing diversity of digital media, digital materials and digital methods. The first section describes the humanities computing tradition formed around the interpretation of computation as a rule-based process connected to a concept of digital...... materials centred on the digitisation of non-digital, finite works, corpora and oeuvres. The second section discusses “the big tent” of contemporary digital humanities. It is argued that there can be no unifying interpretation of digital humanities above the level of studying digital materials with the help...... of software-supported methods. This is so, in part, because of the complexity of the world and, in part, because digital media remain open to the projection of new epistemologies onto the functional architecture of these media. The third section discusses the heterogeneous character of digital materials...

  4. Analysis of thyroid absorbed dose in cervical CT scan with the use of bismuth shielding

    International Nuclear Information System (INIS)

    Santos, Fernanda S.; Gómez, Álvaro M.L.; Mourão, Arnaldo P.; Santana, Priscila C.

    2017-01-01

    The Computed Tomography (CT) has become an important tool to diagnose cancer and to obtain additional information for different clinical questions. Today, it is a very fast, painless and noninvasive test that can be performed high quality images. However, CT scan usually requires a higher radiation exposure dose than a conventional radiography examination. The aim of this study is to determine the dose variation deposited in thyroid and in nearby radiosensitive organs, such as: lenses, pharynx, hypophysis, salivary gland and spinal cord with and without the use of bismuth shielded. A cervical CT scan was performed on anthropomorphic male phantom model Alderson Rando, from the occipital to the first thoracic vertebra, using a GE scanner, Discovery model with 64 channels. Dose measurements have been performed by using radiochromic film strips to register the individual doses in the organs of interest. After the phantom cervical CT scan the radiochromic film strips were processed for obtaining digital images. Digital images were worked to obtain the dose variation profiles for each film. With the data obtained, it was found the organ dose variation. The results show that the thyroid received the highest dose, 40.9 mGy, in the phantom, according to the incidence of the primary X-ray beam. (author)

  5. Analysis of thyroid absorbed dose in cervical CT scan with the use of bismuth shielding

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Fernanda S.; Gómez, Álvaro M.L.; Mourão, Arnaldo P., E-mail: fernanda.stephaniebh@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Santana, Priscila C. [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Anatomia e Imagem

    2017-07-01

    The Computed Tomography (CT) has become an important tool to diagnose cancer and to obtain additional information for different clinical questions. Today, it is a very fast, painless and noninvasive test that can be performed high quality images. However, CT scan usually requires a higher radiation exposure dose than a conventional radiography examination. The aim of this study is to determine the dose variation deposited in thyroid and in nearby radiosensitive organs, such as: lenses, pharynx, hypophysis, salivary gland and spinal cord with and without the use of bismuth shielded. A cervical CT scan was performed on anthropomorphic male phantom model Alderson Rando, from the occipital to the first thoracic vertebra, using a GE scanner, Discovery model with 64 channels. Dose measurements have been performed by using radiochromic film strips to register the individual doses in the organs of interest. After the phantom cervical CT scan the radiochromic film strips were processed for obtaining digital images. Digital images were worked to obtain the dose variation profiles for each film. With the data obtained, it was found the organ dose variation. The results show that the thyroid received the highest dose, 40.9 mGy, in the phantom, according to the incidence of the primary X-ray beam. (author)

  6. Towards machine learned quality control: A benchmark for sharpness quantification in digital pathology.

    Science.gov (United States)

    Campanella, Gabriele; Rajanna, Arjun R; Corsale, Lorraine; Schüffler, Peter J; Yagi, Yukako; Fuchs, Thomas J

    2018-04-01

    Pathology is on the verge of a profound change from an analog and qualitative to a digital and quantitative discipline. This change is mostly driven by the high-throughput scanning of microscope slides in modern pathology departments, reaching tens of thousands of digital slides per month. The resulting vast digital archives form the basis of clinical use in digital pathology and allow large scale machine learning in computational pathology. One of the most crucial bottlenecks of high-throughput scanning is quality control (QC). Currently, digital slides are screened manually to detected out-of-focus regions, to compensate for the limitations of scanner software. We present a solution to this problem by introducing a benchmark dataset for blur detection, an in-depth comparison of state-of-the art sharpness descriptors and their prediction performance within a random forest framework. Furthermore, we show that convolution neural networks, like residual networks, can be used to train blur detectors from scratch. We thoroughly evaluate the accuracy of feature based and deep learning based approaches for sharpness classification (99.74% accuracy) and regression (MSE 0.004) and additionally compare them to domain experts in a comprehensive human perception study. Our pipeline outputs spacial heatmaps enabling to quantify and localize blurred areas on a slide. Finally, we tested the proposed framework in the clinical setting and demonstrate superior performance over the state-of-the-art QC pipeline comprising commercial software and human expert inspection by reducing the error rate from 17% to 4.7%. Copyright © 2017. Published by Elsevier Ltd.

  7. Correction of phase-shifting error in wavelength scanning digital holographic microscopy

    Science.gov (United States)

    Zhang, Xiaolei; Wang, Jie; Zhang, Xiangchao; Xu, Min; Zhang, Hao; Jiang, Xiangqian

    2018-05-01

    Digital holographic microscopy is a promising method for measuring complex micro-structures with high slopes. A quasi-common path interferometric apparatus is adopted to overcome environmental disturbances, and an acousto-optic tunable filter is used to obtain multi-wavelength holograms. However, the phase shifting error caused by the acousto-optic tunable filter reduces the measurement accuracy and, in turn, the reconstructed topographies are erroneous. In this paper, an accurate reconstruction approach is proposed. It corrects the phase-shifting errors by minimizing the difference between the ideal interferograms and the recorded ones. The restriction on the step number and uniformity of the phase shifting is relaxed in the interferometry, and the measurement accuracy for complex surfaces can also be improved. The universality and superiority of the proposed method are demonstrated by practical experiments and comparison to other measurement methods.

  8. Optical 3D scans for orthodontic diagnostics performed on full-arch impressions. Completeness of surface structure representation.

    Science.gov (United States)

    Vogel, Annike B; Kilic, Fatih; Schmidt, Falko; Rübel, Sebastian; Lapatki, Bernd G

    2015-11-01

    The purpose of this work was to evaluate the completeness of surface structure representation offered by full-arch impression scans in different situations of tooth (mal)alignment and whether this completeness could be improved by performing rescans on the same impressions reduced sequentially to different levels of gingival height and by adding extra single scans to the number of single scans recommended by the manufacturer. Three pairs of full-arch resin models were used as reference, characterized either by normal occlusion, by anterior diastematic protrusion (and edentulous spaces in the lower posterior segments), or by anterior crowding. An alginate impression of each arch was taken and digitized with a structured-light scanner, followed by three rescans with the impression cut back to 10, 5, and 1 mm of gingival height. Both the initial scan and the rescans were performed both with 19 basic single scans and with 10 extra single scans. Each impression scan was analyzed for quantitative completeness relative to its homologous direct scan of the original resin model. In addition, the topography of voids in the resultant digital model was assessed by visual inspection. Compared to the homologous reference scans of the original resin models, completeness of the original impression scans--in the absence of both gingival cutback and extra single scans--was 97.23 ± 0.066% in the maxilla or 95.72 ± 0.070% in the mandible with normal occlusion, 91.11 ± 0.132% or 96.07 ± 0.109% in the arches with anterior diastematic protrusion, and 98.24 ± 0.085% or 93.39 ± 0.146% in those with anterior crowding. Gingival cutback and extra single scans were found to improve these values up to 100.35 ± 0.066% or 99.53 ± 0.070% in the arches with normal occlusion, 91.77 ± 0.132% or 97.95 ± 0.109% in those with anterior diastematic protrusion, and 98.59 ± 0.085% or 98.96 ± 0.146% in those with anterior crowding. In strictly quantitative terms, the impression scans did capture

  9. Valley of the unicorns: consumer genomics, venture capital and digital disruption

    OpenAIRE

    Hogarth, Stuart James

    2017-01-01

    Drawing on the sociology of expectations and sociology of conventions, this paper explores issues of worth and value in the bioeconomy, and the promissory character of contemporary capitalism. Arguing that the literature on biocapital has paid insufficient attention to geographical differentiation in capital accumulation strategies, this paper situates the consumer genomics firm 23andme in the entrepreneurial culture of Silicon Valley. The paper suggests that in Silicon Valley the relationshi...

  10. Study of a scanning HIFU therapy protocol, Part II: Experiment and results

    Science.gov (United States)

    Andrew, Marilee A.; Kaczkowski, Peter; Cunitz, Bryan W.; Brayman, Andrew A.; Kargl, Steven G.

    2003-04-01

    Instrumentation and protocols for creating scanned HIFU lesions in freshly excised bovine liver were developed in order to study the in vitro HIFU dose response and validate models. Computer-control of the HIFU transducer and 3-axis positioning system provided precise spatial placement of the thermal lesions. Scan speeds were selected in the range of 1 to 8 mm/s, and the applied electrical power was varied from 20 to 60 W. These parameters were chosen to hold the thermal dose constant. A total of six valid scans of 15 mm length were created in each sample; a 3.5 MHz single-element, spherically focused transducer was used. Treated samples were frozen, then sliced in 1.27 mm increments. Digital photographs of slices were downloaded to computer for image processing and analysis. Lesion characteristics, including the depth within the tissue, axial length, and radial width, were computed. Results were compared with those generated from modified KZK and BHTE models, and include a comparison of the statistical variation in the across-scan lesion radial width. [Work supported by USAMRMC.

  11. Evolution of genome size and complexity in the rhabdoviridae.

    Directory of Open Access Journals (Sweden)

    Peter J Walker

    2015-02-01

    Full Text Available RNA viruses exhibit substantial structural, ecological and genomic diversity. However, genome size in RNA viruses is likely limited by a high mutation rate, resulting in the evolution of various mechanisms to increase complexity while minimising genome expansion. Here we conduct a large-scale analysis of the genome sequences of 99 animal rhabdoviruses, including 45 genomes which we determined de novo, to identify patterns of genome expansion and the evolution of genome complexity. All but seven of the rhabdoviruses clustered into 17 well-supported monophyletic groups, of which eight corresponded to established genera, seven were assigned as new genera, and two were taxonomically ambiguous. We show that the acquisition and loss of new genes appears to have been a central theme of rhabdovirus evolution, and has been associated with the appearance of alternative, overlapping and consecutive ORFs within the major structural protein genes, and the insertion and loss of additional ORFs in each gene junction in a clade-specific manner. Changes in the lengths of gene junctions accounted for as much as 48.5% of the variation in genome size from the smallest to the largest genome, and the frequency with which new ORFs were observed increased in the 3' to 5' direction along the genome. We also identify several new families of accessory genes encoded in these regions, and show that non-canonical expression strategies involving TURBS-like termination-reinitiation, ribosomal frame-shifts and leaky ribosomal scanning appear to be common. We conclude that rhabdoviruses have an unusual capacity for genomic plasticity that may be linked to their discontinuous transcription strategy from the negative-sense single-stranded RNA genome, and propose a model that accounts for the regular occurrence of genome expansion and contraction throughout the evolution of the Rhabdoviridae.

  12. Evolution of genome size and complexity in the rhabdoviridae.

    Science.gov (United States)

    Walker, Peter J; Firth, Cadhla; Widen, Steven G; Blasdell, Kim R; Guzman, Hilda; Wood, Thomas G; Paradkar, Prasad N; Holmes, Edward C; Tesh, Robert B; Vasilakis, Nikos

    2015-02-01

    RNA viruses exhibit substantial structural, ecological and genomic diversity. However, genome size in RNA viruses is likely limited by a high mutation rate, resulting in the evolution of various mechanisms to increase complexity while minimising genome expansion. Here we conduct a large-scale analysis of the genome sequences of 99 animal rhabdoviruses, including 45 genomes which we determined de novo, to identify patterns of genome expansion and the evolution of genome complexity. All but seven of the rhabdoviruses clustered into 17 well-supported monophyletic groups, of which eight corresponded to established genera, seven were assigned as new genera, and two were taxonomically ambiguous. We show that the acquisition and loss of new genes appears to have been a central theme of rhabdovirus evolution, and has been associated with the appearance of alternative, overlapping and consecutive ORFs within the major structural protein genes, and the insertion and loss of additional ORFs in each gene junction in a clade-specific manner. Changes in the lengths of gene junctions accounted for as much as 48.5% of the variation in genome size from the smallest to the largest genome, and the frequency with which new ORFs were observed increased in the 3' to 5' direction along the genome. We also identify several new families of accessory genes encoded in these regions, and show that non-canonical expression strategies involving TURBS-like termination-reinitiation, ribosomal frame-shifts and leaky ribosomal scanning appear to be common. We conclude that rhabdoviruses have an unusual capacity for genomic plasticity that may be linked to their discontinuous transcription strategy from the negative-sense single-stranded RNA genome, and propose a model that accounts for the regular occurrence of genome expansion and contraction throughout the evolution of the Rhabdoviridae.

  13. Evolution of Genome Size and Complexity in the Rhabdoviridae

    Science.gov (United States)

    Walker, Peter J.; Firth, Cadhla; Widen, Steven G.; Blasdell, Kim R.; Guzman, Hilda; Wood, Thomas G.; Paradkar, Prasad N.; Holmes, Edward C.; Tesh, Robert B.; Vasilakis, Nikos

    2015-01-01

    RNA viruses exhibit substantial structural, ecological and genomic diversity. However, genome size in RNA viruses is likely limited by a high mutation rate, resulting in the evolution of various mechanisms to increase complexity while minimising genome expansion. Here we conduct a large-scale analysis of the genome sequences of 99 animal rhabdoviruses, including 45 genomes which we determined de novo, to identify patterns of genome expansion and the evolution of genome complexity. All but seven of the rhabdoviruses clustered into 17 well-supported monophyletic groups, of which eight corresponded to established genera, seven were assigned as new genera, and two were taxonomically ambiguous. We show that the acquisition and loss of new genes appears to have been a central theme of rhabdovirus evolution, and has been associated with the appearance of alternative, overlapping and consecutive ORFs within the major structural protein genes, and the insertion and loss of additional ORFs in each gene junction in a clade-specific manner. Changes in the lengths of gene junctions accounted for as much as 48.5% of the variation in genome size from the smallest to the largest genome, and the frequency with which new ORFs were observed increased in the 3’ to 5’ direction along the genome. We also identify several new families of accessory genes encoded in these regions, and show that non-canonical expression strategies involving TURBS-like termination-reinitiation, ribosomal frame-shifts and leaky ribosomal scanning appear to be common. We conclude that rhabdoviruses have an unusual capacity for genomic plasticity that may be linked to their discontinuous transcription strategy from the negative-sense single-stranded RNA genome, and propose a model that accounts for the regular occurrence of genome expansion and contraction throughout the evolution of the Rhabdoviridae. PMID:25679389

  14. Investigation of crack origin in hybrid components with twocolor digital Fresnel holography

    Directory of Open Access Journals (Sweden)

    Moisson E.

    2010-06-01

    Full Text Available The paper presents a two-color digital holographic interferometer. The set-up is devoted to the investigation of crack origin in hybrid industrial electronic components. Optical configuration and algorithms to recover the optical phase of two-color digitally encoded holograms are described. The method is based on a spatial-color-multiplexing scheme in which holographic reconstruction is performed using a spectral scanning algorithm. Experimental results exhibit in-plane and out-of-plane non uniform deformations that are the probable cause of the cracking of the component.

  15. A 4D digital phantom for patient-specific simulation of brain CT perfusion protocols.

    Science.gov (United States)

    van den Boom, Rieneke; Manniesing, Rashindra; Oei, Marcel T H; van der Woude, Willem-Jan; Smit, Ewoud J; Laue, Hendrik O A; van Ginneken, Bram; Prokop, Mathias

    2014-07-01

    Optimizing CT brain perfusion protocols is a challenge because of the complex interaction between image acquisition, calculation of perfusion data, and patient hemodynamics. Several digital phantoms have been developed to avoid unnecessary patient exposure or suboptimum choice of parameters. The authors expand this idea by using realistic noise patterns and measured tissue attenuation curves representing patient-specific hemodynamics. The purpose of this work is to validate that this approach can realistically simulate mean perfusion values and noise on perfusion data for individual patients. The proposed 4D digital phantom consists of three major components: (1) a definition of the spatial structure of various brain tissues within the phantom, (2) measured tissue attenuation curves, and (3) measured noise patterns. Tissue attenuation curves were measured in patient data using regions of interest in gray matter and white matter. By assigning the tissue attenuation curves to the corresponding tissue curves within the phantom, patient-specific CTP acquisitions were retrospectively simulated. Noise patterns were acquired by repeatedly scanning an anthropomorphic skull phantom at various exposure settings. The authors selected 20 consecutive patients that were scanned for suspected ischemic stroke and constructed patient-specific 4D digital phantoms using the individual patients' hemodynamics. The perfusion maps of the patient data were compared with the digital phantom data. Agreement between phantom- and patient-derived data was determined for mean perfusion values and for standard deviation in de perfusion data using intraclass correlation coefficients (ICCs) and a linear fit. ICCs ranged between 0.92 and 0.99 for mean perfusion values. ICCs for the standard deviation in perfusion maps were between 0.86 and 0.93. Linear fitting yielded slope values between 0.90 and 1.06. A patient-specific 4D digital phantom allows for realistic simulation of mean values and

  16. Digital differential confocal microscopy based on spatial shift transformation.

    Science.gov (United States)

    Liu, J; Wang, Y; Liu, C; Wilson, T; Wang, H; Tan, J

    2014-11-01

    Differential confocal microscopy is a particularly powerful surface profilometry technique in industrial metrology due to its high axial sensitivity and insensitivity to noise. However, the practical implementation of the technique requires the accurate positioning of point detectors in three-dimensions. We describe a simple alternative based on spatial transformation of a through-focus series of images obtained from a homemade beam scanning confocal microscope. This digital differential confocal microscopy approach is described and compared with the traditional Differential confocal microscopy approach. The ease of use of the digital differential confocal microscopy system is illustrated by performing measurements on a 3D standard specimen. © 2014 The Authors Journal of Microscopy © 2014 Royal Microscopical Society.

  17. Digital Archive of UkrVO: first results of MAO NASU Solar System Bodies photographic plate processing

    Science.gov (United States)

    Ivanov, G.; Pakuliak, L.; Shatokhina, S.; Yizhakevych, E.; Kazantseva, L.; Andruk, V.

    The digitizing and processing of photographic plates with the images of the outer planets and their satellites from the archive collections of MAO NASU and AO of Kiev university included into the UkrVO Joint Digital Archive (JDA) have been made. Plates were obtained in the last half of the 20th century. The digitizing of JDA archive plates and inclusion of plate preview images into GPA database has been under way, using two models of flatbed scanners: Microtek ScanMaker 9800XL TMA and Epson Expression 10000XL. The database with metadata of plates is allocated on the computational resources of MAO NASU (http://gua.db.ukr-vo.org). Plates have been scanned at 16-bits grey dynamic range, with a resolution of 1200-1600 dpi, and saved in TIFF format. Linear dimensions of images are up to 13 thousand pixels (for plates 30.30 cm). The astrometric and photometric calibration procedures have been done in the LINUX-MIDASROMAFOT environment and Tycho-2 as reference with the image processing procedure specially developed for digitized images of huge linear dimensions on the basis of the image inherent traits. First results of digitized plate processing give the rms errors of 10 and 20 mas for RA, DEC respectively. (O-C) for plates with Pluto in comparison to JPL PLU021.DE405 has been derived of 140(RA) and 270(DEC) mas.

  18. Lung cancer detection with digital chest tomosynthesis: first round results from the SOS observational study.

    Science.gov (United States)

    Bertolaccini, Luca; Viti, Andrea; Tavella, Chiara; Priotto, Roberto; Ghirardo, Donatella; Grosso, Maurizio; Terzi, Alberto

    2015-04-01

    Baseline results of the Studio OSservazionale (SOS), observational study, a single-arm observational study of digital chest tomosynthesis for lung cancer detection in an at-risk population demonstrated a detection rate of lung cancer comparable to that of studies that used low dose CT scan (LDCT). We present the results of the first round. Totally 1,703 out of 1,843 (92%) subjects who had a baseline digital chest tomosynthesis underwent a first round reevaluation after 1 year. At first round chest digital tomosynthesis, 13 (0.7%) subjects had an indeterminate nodule larger than 5 mm and underwent low-dose CT scan for nodule confirmation. PET/CT study was obtained in 10 (0.5%) subjects and 2 subjects had a low-dose CT follow up. Surgery, either video-assisted thoracoscopic or open surgery for indeterminate pulmonary nodules was performed in 10 (0.2%) subjects. A lung cancer was diagnosed and resected in five patients. The lung cancer detection rate at first round was 0.3% (5/1,703). The detection rate of lung cancer at first round for tomosynthesis is comparable to rates reported for CT. In addition, results of first round digital chest tomosynthesis confirm chest tomosynthesis as a possible first-line lung cancer-screening tool.

  19. Metrological large range scanning probe microscope

    International Nuclear Information System (INIS)

    Dai Gaoliang; Pohlenz, Frank; Danzebrink, Hans-Ulrich; Xu Min; Hasche, Klaus; Wilkening, Guenter

    2004-01-01

    We describe a metrological large range scanning probe microscope (LR-SPM) with an Abbe error free design and direct interferometric position measurement capability, aimed at versatile traceable topographic measurements that require nanometer accuracy. A dual-stage positioning system was designed to achieve both a large measurement range and a high measurement speed. This dual-stage system consists of a commercially available stage, referred to as nanomeasuring machine (NMM), with a motion range of 25 mmx25 mmx5 mm along x, y, and z axes, and a compact z-axis piezoelectric positioning stage (compact z stage) with an extension range of 2 μm. The metrological LR-SPM described here senses the surface using a stationary fixed scanning force microscope (SFM) head working in contact mode. During operation, lateral scanning of the sample is performed solely by the NMM. Whereas the z motion, controlled by the SFM signal, is carried out by a combination of the NMM and the compact z stage. In this case the compact z stage, with its high mechanical resonance frequency (greater than 20 kHz), is responsible for the rapid motion while the NMM simultaneously makes slower movements over a larger motion range. To reduce the Abbe offset to a minimum the SFM tip is located at the intersection of three interferometer measurement beams orientated in x, y, and z directions. To improve real time performance two high-end digital signal processing (DSP) systems are used for NMM positioning and SFM servocontrol. Comprehensive DSP firmware and Windows XP-based software are implemented, providing a flexible and user-friendly interface. The instrument is able to perform large area imaging or profile scanning directly without stitching small scanned images. Several measurements on different samples such as flatness standards, nanostep height standards, roughness standards as well as sharp nanoedge samples and 1D gratings demonstrate the outstanding metrological capabilities of the instrument

  20. Digital Preservation of Photo Journalism (Case Study of the Kompas Daily

    Directory of Open Access Journals (Sweden)

    Yuli Rahmawati

    2017-01-01

    Full Text Available Newspaper provides many information from politics, economics, cultures, and sports for society. Newspaper reports important events in the world. Besides the news, there also some pictures portraying those events. So readers will easilly to see what happen visually. According to the journalistic concept, photos has comply as a reference source. Kompas daily, firstly published on 1965, and published many historical photos both paper and digital format. The digitize process is done by kompas information center, through scanning, indexing, and syncronizing. Two most important issues are standardization of metadata and integrated retrieval systems. Standarization of metadata was design based on publishing standard,  IIM and was modified with IPTC news codes. Information retrieval systems was built by inserting information about publication. This system connecting photo creating data, storage systems, and retrieval systems. For kompas daily, the availability if digital object  such as photo can trigger the innitiatives of re-publishing historical momments in thematical rubrics. Digitize will give benefits for information disemination.

  1. Genome-wide scan of gastrointestinal nematode resistance in closed Angus population selected for minimized influence of MHC.

    Science.gov (United States)

    Kim, Eui-Soo; Sonstegard, Tad S; da Silva, Marcos V G B; Gasbarre, Louis C; Van Tassell, Curtis P

    2015-01-01

    Genetic markers associated with parasite indicator traits are ideal targets for study of marker assisted selection aimed at controlling infections that reduce herd use of anthelminthics. For this study, we collected gastrointestinal (GI) nematode fecal egg count (FEC) data from post-weaning animals of an Angus resource population challenged to a 26 week natural exposure on pasture. In all, data from 487 animals was collected over a 16 year period between 1992 and 2007, most of which were selected for a specific DRB1 allele to reduce the influence of potential allelic variant effects of the MHC locus. A genome-wide association study (GWAS) based on BovineSNP50 genotypes revealed six genomic regions located on bovine Chromosomes 3, 5, 8, 15 and 27; which were significantly associated (-log10 p=4.3) with Box-Cox transformed mean FEC (BC-MFEC). DAVID analysis of the genes within the significant genomic regions suggested a correlation between our results and annotation for genes involved in inflammatory response to infection. Furthermore, ROH and selection signature analyses provided strong evidence that the genomic regions associated BC-MFEC have not been affected by local autozygosity or recent experimental selection. These findings provide useful information for parasite resistance prediction for young grazing cattle and suggest new candidate gene targets for development of disease-modifying therapies or future studies of host response to GI parasite infection.

  2. Sandwich corrected standard errors in family-based genome-wide association studies

    NARCIS (Netherlands)

    Minica, C.C.; Dolan, C.V.; Kampert, M.M.D.; Boomsma, D.I.; Vink, J.M.

    2015-01-01

    Given the availability of genotype and phenotype data collected in family members, the question arises which estimator ensures the most optimal use of such data in genome-wide scans. Using simulations, we compared the Unweighted Least Squares (ULS) and Maximum Likelihood (ML) procedures. The former

  3. Survey of protein–DNA interactions in Aspergillus oryzae on a genomic scale

    Science.gov (United States)

    Wang, Chao; Lv, Yangyong; Wang, Bin; Yin, Chao; Lin, Ying; Pan, Li

    2015-01-01

    The genome-scale delineation of in vivo protein–DNA interactions is key to understanding genome function. Only ∼5% of transcription factors (TFs) in the Aspergillus genus have been identified using traditional methods. Although the Aspergillus oryzae genome contains >600 TFs, knowledge of the in vivo genome-wide TF-binding sites (TFBSs) in aspergilli remains limited because of the lack of high-quality antibodies. We investigated the landscape of in vivo protein–DNA interactions across the A. oryzae genome through coupling the DNase I digestion of intact nuclei with massively parallel sequencing and the analysis of cleavage patterns in protein–DNA interactions at single-nucleotide resolution. The resulting map identified overrepresented de novo TF-binding motifs from genomic footprints, and provided the detailed chromatin remodeling patterns and the distribution of digital footprints near transcription start sites. The TFBSs of 19 known Aspergillus TFs were also identified based on DNase I digestion data surrounding potential binding sites in conjunction with TF binding specificity information. We observed that the cleavage patterns of TFBSs were dependent on the orientation of TF motifs and independent of strand orientation, consistent with the DNA shape features of binding motifs with flanking sequences. PMID:25883143

  4. Digital Workflow for the Conservation of Bahrain Built Heritage: the Sheik Isa Bin ALI House

    Science.gov (United States)

    Barazzetti, L.; Mezzino, D.; Santana Quintero, M.

    2017-08-01

    Currently, the commercial market offers several tools for digital documentation of historic sites and buildings. Photogrammetry and laser scanning play a fundamental role in the acquisition of metric information, which is then processed to generate reliable records particularly useful also in the built heritage conservation field. Although potentially very fast and accurate, such techniques require expert operators to produce reliable results, especially in the case of complex and large sites. The aim of this paper is to present the digital workflow developed for data acquisition and processing of the Shaikh Isa Bin Ali house in Muharraq, Bahrain. This historic structure is an outstanding example of Bahrain architecture as well as tangible memory of the country history, with strong connotations in the Bahrain cultural identity. The building has been documented employing several digital techniques, including: aerial (drone) and terrestrial photogrammetry, rectifying photography, total station and laser scanning. The documentation project has been developed for the Bahrain Authority for Culture and Antiquities (BACA) by a multidisciplinary team of experts from Carleton Immersive Media Studio (CIMS, Carleton University, Canada) and Gicarus Lab (Politecnico di Milano, Italy).

  5. Genome-wide linkage scan for primary open angle glaucoma: influences of ancestry and age at diagnosis.

    Directory of Open Access Journals (Sweden)

    Kristy R Crooks

    Full Text Available Primary open-angle glaucoma (POAG is the most common form of glaucoma and one of the leading causes of vision loss worldwide. The genetic etiology of POAG is complex and poorly understood. The purpose of this work is to identify genomic regions of interest linked to POAG. This study is the largest genetic linkage study of POAG performed to date: genomic DNA samples from 786 subjects (538 Caucasian ancestry, 248 African ancestry were genotyped using either the Illumina GoldenGate Linkage 4 Panel or the Illumina Infinium Human Linkage-12 Panel. A total of 5233 SNPs was analyzed in 134 multiplex POAG families (89 Caucasian ancestry, 45 African ancestry. Parametric and non-parametric linkage analyses were performed on the overall dataset and within race-specific datasets (Caucasian ancestry and African ancestry. Ordered subset analysis was used to stratify the data on the basis of age of glaucoma diagnosis. Novel linkage regions were identified on chromosomes 1 and 20, and two previously described loci-GLC1D on chromosome 8 and GLC1I on chromosome 15--were replicated. These data will prove valuable in the context of interpreting results from genome-wide association studies for POAG.

  6. Image analysis of microsialograms of the mouse parotid gland using digital image processing

    International Nuclear Information System (INIS)

    Yoshiura, K.; Ohki, M.; Yamada, N.

    1991-01-01

    The authors compared two digital-image feature-extraction methods for the analysis of microsialograms of the mouse parotid gland following either overfilling, experimentally induced acute sialoadenitis or irradiation. Microsialograms were digitized using a drum-scanning microdensitometer. The grey levels were then partitioned into four bands representing soft tissue, peripheral minor, middle-sized and major ducts, and run-length and histogram analysis of the digital images performed. Serial analysis of microsialograms during progressive filling showed that both methods depicted the structural characteristics of the ducts at each grey level. However, in the experimental groups, run-length analysis showed slight changes in the peripheral duct system more clearly. This method was therefore considered more effective than histogram analysis

  7. Volumetry of human taste buds using laser scanning microscopy.

    Science.gov (United States)

    Just, T; Srur, E; Stachs, O; Pau, H W

    2009-10-01

    In vivo laser scanning confocal microscopy is a relatively new, non-invasive method for assessment of oral cavity epithelia. The penetration depth of approximately 200-400 microm allows visualisation of fungiform papillae and their taste buds. This paper describes the technique of in vivo volumetry of human taste buds. Confocal laser scanning microscopy used a diode laser at 670 nm for illumination. Digital laser scanning confocal microscopy equipment consisted of the Heidelberg Retina Tomograph HRTII and the Rostock Cornea Module. Volume scans of fungiform papillae were used for three-dimensional reconstruction of the taste bud. This technique supplied information on taste bud structure and enabled measurement and calculation of taste bud volume. Volumetric data from a 23-year-old man over a nine-day period showed only a small deviation in values. After three to four weeks, phenomenological changes in taste bud structures were found (i.e. a significant increase in volume, followed by disappearance of the taste bud and appearance of a new taste bud). The data obtained indicate the potential application of this non-invasive imaging modality: to evaluate variation of taste bud volume in human fungiform papillae with ageing; to study the effects of chorda tympani nerve transection on taste bud volume; and to demonstrate recovery of taste buds in patients with a severed chorda tympani nerve who show recovery of gustatory sensibility after surgery.

  8. High-speed automated NDT device for niobium plate using scanning laser acoustic microscopy

    International Nuclear Information System (INIS)

    Oravecz, M.G.; Yu, B.Y.; Riney, K.; Kessler, L.W.; Padamsee, H.

    1988-01-01

    This paper presents a nondestructive testing (NDT) device which rapidly and automatically identifies defects throughout the volume of a 23.4 cm x 23.4 cm x 0.3 cm, pure niobium plate using Scanning Laser Acoustic Microscope (SLAM), high-resolution, 60 MHz, ultrasonic images. A principle advantage of the SLAM technique is that it combines a video scan rate with a high scan density (130 lines/mm at 60 MHz). To automate the inspection system they integrated under computer control the following: the SLAM RS-170/330 video output, a computerized XY plate scanner, a real-time video digitizer/integrator, a computer algorithm for defect detection, a digital mass storage device, and a hardcopy output device. The key element was development of an efficient, reliable defect detection algorithm using a variance filter with a locally determined threshold. This algorithm is responsible for recognizing valid flaws in the midst of random texture. This texture was seen throughout the acoustic images and was caused by the niobium microstructure. The images, as analyzed, contained 128 x 120 pixels with 64 grey levels per pixel. This system allows economical inspection of the large quantities (eg. 100 tons) of material needed for future particle accelerators based on microwave superconductivity. Rapid nondestructive inspection of pure niobium sheet is required because current accelerator performance is largely limited by the quality of commercially available material. Previous work documented critical flaws that are detectable by SLAM techniques. 15 references, 9 figures

  9. The pig genome project has plenty to squeal about.

    Science.gov (United States)

    Fan, B; Gorbach, D M; Rothschild, M F

    2011-01-01

    Significant progress on pig genetics and genomics research has been witnessed in recent years due to the integration of advanced molecular biology techniques, bioinformatics and computational biology, and the collaborative efforts of researchers in the swine genomics community. Progress on expanding the linkage map has slowed down, but the efforts have created a higher-resolution physical map integrating the clone map and BAC end sequence. The number of QTL mapped is still growing and most of the updated QTL mapping results are available through PigQTLdb. Additionally, expression studies using high-throughput microarrays and other gene expression techniques have made significant advancements. The number of identified non-coding RNAs is rapidly increasing and their exact regulatory functions are being explored. A publishable draft (build 10) of the swine genome sequence was available for the pig genomics community by the end of December 2010. Build 9 of the porcine genome is currently available with Ensembl annotation; manual annotation is ongoing. These drafts provide useful tools for such endeavors as comparative genomics and SNP scans for fine QTL mapping. A recent community-wide effort to create a 60K porcine SNP chip has greatly facilitated whole-genome association analyses, haplotype block construction and linkage disequilibrium mapping, which can contribute to whole-genome selection. The future 'systems biology' that integrates and optimizes the information from all research levels can enhance the pig community's understanding of the full complexity of the porcine genome. These recent technological advances and where they may lead are reviewed. Copyright © 2011 S. Karger AG, Basel.

  10. Meta-analysis of genome-wide linkage studies in BMI and obesity

    NARCIS (Netherlands)

    Saunders, Catherine L.; Chiodini, Benedetta D.; Sham, Pak; Lewis, Cathryn M.; Abkevich, Victor; Adeyemo, Adebowale A.; de Andrade, Mariza; Arya, Rector; Berenson, Gerald S.; Blangero, John; Boehnke, Michael; Borecki, Ingrid B.; Chagnon, Yvon C.; Chen, Wei; Comuzzie, Anthony G.; Deng, Hong-Wen; Duggirala, Ravindranath; Feitosa, Mary F.; Froguel, Philippe; Hanson, Robert L.; Hebebrand, Johannes; Huezo-Dias, Patricia; Kissebah, Ahmed H.; Li, Weidong; Luke, Amy; Martin, Lisa J.; Nash, Matthew; Ohman, Muena; Palmer, Lyle J.; Peltonen, Leena; Perola, Markus; Price, R. Arlen; Redline, Susan; Srinivasan, Sathanur R.; Stern, Michael P.; Stone, Steven; Stringham, Heather; Turner, Stephen; Wijmenga, Cisca; Collier, David A.

    Objective: The objective was to provide an overall assessment of genetic linkage data of BMI and BMI-defined obesity using a nonparametric genome scan meta-analysis. Research Methods and Procedures: We identified 37 published studies containing data on over 31,000 individuals from more than >10,000

  11. Application of intra-oral dental scanners in the digital workflow of implantology

    NARCIS (Netherlands)

    van der Meer, Wicher J; Andriessen, Frank S; Wismeijer, Daniel; Ren, Yijin

    2012-01-01

    UNLABELLED: Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. MATERIALS AND METHODS: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned

  12. Application of intra-oral dental scanners in the digital workflow of implantology

    NARCIS (Netherlands)

    van der Meer, W.J.; Andriessen, F.S.; Wismeijer, D.; Ren, Y.

    2012-01-01

    Intra-oral scanners will play a central role in digital dentistry in the near future. In this study the accuracy of three intra-oral scanners was compared. Materials and methods: A master model made of stone was fitted with three high precision manufactured PEEK cylinders and scanned with three

  13. Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision.

    Science.gov (United States)

    Jeon, Jin-Hun; Kim, Hae-Young; Kim, Ji-Hwan; Kim, Woong-Chul

    2014-12-01

    This study aimed to evaluate the accuracy of digitizing dental impressions of abutment teeth using a white light scanner and to compare the findings among teeth types. To assess precision, impressions of the canine, premolar, and molar prepared to receive all-ceramic crowns were repeatedly scanned to obtain five sets of 3-D data (STL files). Point clouds were compared and error sizes were measured (n=10 per type). Next, to evaluate trueness, impressions of teeth were rotated by 10°-20° and scanned. The obtained data were compared with the first set of data for precision assessment, and the error sizes were measured (n=5 per type). The Kruskal-Wallis test was performed to evaluate precision and trueness among three teeth types, and post-hoc comparisons were performed using the Mann-Whitney U test with Bonferroni correction (α=.05). Precision discrepancies for the canine, premolar, and molar were 3.7 µm, 3.2 µm, and 7.3 µm, respectively, indicating the poorest precision for the molar (Pimpressions of abutment teeth using a white light scanner was assessed to be a highly accurate method and provided discrepancy values in a clinically acceptable range. Further study is needed to improve digitizing performance of white light scanning in axial wall.

  14. Resolution analysis of archive films for the purpose of their optimal digitization and distribution

    Science.gov (United States)

    Fliegel, Karel; Vítek, Stanislav; Páta, Petr; Myslík, Jiří; Pecák, Josef; Jícha, Marek

    2017-09-01

    With recent high demand for ultra-high-definition (UHD) content to be screened in high-end digital movie theaters but also in the home environment, film archives full of movies in high-definition and above are in the scope of UHD content providers. Movies captured with the traditional film technology represent a virtually unlimited source of UHD content. The goal to maintain complete image information is also related to the choice of scanning resolution and spatial resolution for further distribution. It might seem that scanning the film material in the highest possible resolution using state-of-the-art film scanners and also its distribution in this resolution is the right choice. The information content of the digitized images is however limited, and various degradations moreover lead to its further reduction. Digital distribution of the content in the highest image resolution might be therefore unnecessary or uneconomical. In other cases, the highest possible resolution is inevitable if we want to preserve fine scene details or film grain structure for archiving purposes. This paper deals with the image detail content analysis of archive film records. The resolution limit in captured scene image and factors which lower the final resolution are discussed. Methods are proposed to determine the spatial details of the film picture based on the analysis of its digitized image data. These procedures allow determining recommendations for optimal distribution of digitized video content intended for various display devices with lower resolutions. Obtained results are illustrated on spatial downsampling use case scenario, and performance evaluation of the proposed techniques is presented.

  15. Evaluating osteological ageing from digital data

    DEFF Research Database (Denmark)

    Villa, Chiara; Buckberry, Jo; Lynnerup, Niels

    2018-01-01

    Age at death estimation of human skeletal remains is one of the key issues in constructing a biological profile both in forensic and archaeological contexts. The traditional adult osteological methods evaluate macroscopically the morphological changes that occur with increasing age of specific...... on how the osteological age-related changes have been evaluated in digital data. First, the 3D virtual copies of the bones have been used to mimic the appearance of the dry bones and the application of the traditional methods. Secondly, the information directly extrapolated from CT scans has been used...

  16. Genome-wide scan of gastrointestinal nematode resistance in closed Angus population selected for minimized influence of MHC.

    Directory of Open Access Journals (Sweden)

    Eui-Soo Kim

    Full Text Available Genetic markers associated with parasite indicator traits are ideal targets for study of marker assisted selection aimed at controlling infections that reduce herd use of anthelminthics. For this study, we collected gastrointestinal (GI nematode fecal egg count (FEC data from post-weaning animals of an Angus resource population challenged to a 26 week natural exposure on pasture. In all, data from 487 animals was collected over a 16 year period between 1992 and 2007, most of which were selected for a specific DRB1 allele to reduce the influence of potential allelic variant effects of the MHC locus. A genome-wide association study (GWAS based on BovineSNP50 genotypes revealed six genomic regions located on bovine Chromosomes 3, 5, 8, 15 and 27; which were significantly associated (-log10 p=4.3 with Box-Cox transformed mean FEC (BC-MFEC. DAVID analysis of the genes within the significant genomic regions suggested a correlation between our results and annotation for genes involved in inflammatory response to infection. Furthermore, ROH and selection signature analyses provided strong evidence that the genomic regions associated BC-MFEC have not been affected by local autozygosity or recent experimental selection. These findings provide useful information for parasite resistance prediction for young grazing cattle and suggest new candidate gene targets for development of disease-modifying therapies or future studies of host response to GI parasite infection.

  17. Determination of tire cross-sectional geometric characteristics from a digitally scanned image

    Science.gov (United States)

    Danielson, Kent T.

    1995-08-01

    A semi-automated procedure is described for the accurate determination of geometrical characteristics using a scanned image of the tire cross-section. The procedure can be useful for cases when CAD drawings are not available or when a description of the actual cured tire is desired. Curves representing the perimeter of the tire cross-section are determined by an edge tracing scheme, and the plyline and cord-end positions are determined by locations of color intensities. The procedure provides an accurate description of the perimeter of the tire cross-section and the locations of plylines and cord-ends. The position, normals, and curvatures of the cross-sectional surface are included in this description. The locations of the plylines provide the necessary information for determining the ply thicknesses and relative position to a reference surface. Finally, the locations of the cord-ends provide a means to calculate the cord-ends per inch (epi). Menu driven software has been developed to facilitate the procedure using the commercial code, PV-Wave by Visual Numerics, Inc., to display the images. From a single user interface, separate modules are executed for image enhancement, curve fitting the edge trace of the cross-sectional perimeter, and determining the plyline and cord-end locations. The code can run on SUN or SGI workstations and requires the use of a mouse to specify options or identify items on the scanned image.

  18. Comparing whole slide digital images versus traditional glass slides in the detection of common microscopic features seen in dermatitis

    Directory of Open Access Journals (Sweden)

    Nikki S Vyas

    2016-01-01

    Full Text Available Background: The quality and limitations of digital slides are not fully known. We aimed to estimate intrapathologist discrepancy in detecting specific microscopic features on glass slides and digital slides created by scanning at ×20. Methods: Hematoxylin and eosin and periodic acid-Schiff glass slides were digitized using the Mirax Scan (Carl Zeiss Inc., Germany. Six pathologists assessed 50-71 digital slides. We recorded objective magnification, total time, and detection of the following: Mast cells; eosinophils; plasma cells; pigmented macrophages; melanin in the epidermis; fungal bodies; neutrophils; civatte bodies; parakeratosis; and sebocytes. This process was repeated using the corresponding glass slides after 3 weeks. The diagnosis was not required. Results: The mean time to assess digital slides was 176.77 s and 137.61 s for glass slides (P < 0.001, 99% confidence interval [CI]. The mean objective magnification used to detect features using digital slides was 18.28 and 14.07 for glass slides (P < 0.001, 99.99% CI. Parakeratosis, civatte bodies, pigmented macrophages, melanin in the epidermis, mast cells, eosinophils, plasma cells, and neutrophils, were identified at lower objectives on glass slides (P = 0.023-0.001, 95% CI. Average intraobserver concordance ranged from κ = 0.30 to κ = 0.78. Features with poor to fair average concordance were: Melanin in the epidermis (κ = 0.15-0.58; plasma cells (κ = 0.15-0.49; and neutrophils (κ = 0.12-0.48. Features with moderate average intrapathologist concordance were: parakeratosis (κ = 0.21-0.61; civatte bodies (κ = 0.21-0.71; pigment-laden macrophages (κ = 0.34-0.66; mast cells (κ = 0.29-0.78; and eosinophils (κ = 0.31-0.79. The average intrapathologist concordance was good for sebocytes (κ = 0.51-1.00 and fungal bodies (κ = 0.47-0.76. Conclusions: Telepathology using digital slides scanned at ×20 is sufficient for detection of histopathologic features routinely encountered in

  19. Digital broadcasting

    International Nuclear Information System (INIS)

    Park, Ji Hyeong

    1999-06-01

    This book contains twelve chapters, which deals with digitization of broadcast signal such as digital open, digitization of video signal and sound signal digitization of broadcasting equipment like DTPP and digital VTR, digitization of equipment to transmit such as digital STL, digital FPU and digital SNG, digitization of transmit about digital TV transmit and radio transmit, digital broadcasting system on necessity and advantage, digital broadcasting system abroad and Korea, digital broadcasting of outline, advantage of digital TV, ripple effect of digital broadcasting and consideration of digital broadcasting, ground wave digital broadcasting of DVB-T in Europe DTV in U.S.A and ISDB-T in Japan, HDTV broadcasting, satellite broadcasting, digital TV broadcasting in Korea, digital radio broadcasting and new broadcasting service.

  20. Accuracy of Intraoral Digital Impressions for Whole Upper Jaws, Including Full Dentitions and Palatal Soft Tissues.

    Directory of Open Access Journals (Sweden)

    Ning Gan

    Full Text Available Intraoral digital impressions have been stated to meet the clinical requirements for some teeth-supported restorations, though fewer evidences were proposed for larger scanning range. The aim of this study was to compare the accuracy (trueness and precision of intraoral digital impressions for whole upper jaws, including the full dentitions and palatal soft tissues, as well as to determine the effect of different palatal vault height or arch width on accuracy of intraoral digital impressions. Thirty-two volunteers were divided into three groups according to the palatal vault height or arch width. Each volunteer received three scans with TRIOS intraoral scanner and one conventional impression of whole upper jaw. Three-dimensional (3D images digitized from conventional gypsum casts by a laboratory scanner were chose as the reference models. All datasets were imported to a specific software program for 3D analysis by "best fit alignment" and "3D compare" process. Color-coded deviation maps showed qualitative visualization of the deviations. For the digital impressions for palatal soft tissues, trueness was (130.54±33.95μm and precision was (55.26±11.21μm. For the digital impressions for upper full dentitions, trueness was (80.01±17.78μm and precision was (59.52±11.29μm. Larger deviations were found between intraoral digital impressions and conventional impressions in the areas of palatal soft tissues than that in the areas of full dentitions (p0.05, but arch width was found to have a significant effect on precision of intraoral digital impressions for full dentitions (p = 0.016. A linear correlation was found between arch width and precision of digital impressions for whole upper jaws (r = 0.326, p = 0.034 for palatal soft tissues and r = 0.485, p = 0.002 for full dentitions. It was feasible to use the intraoral scanner to obtain digital impressions for whole upper jaws. Wider dental arch contributed to lower precision of an intraoral